DOT National Transportation Integrated Search
1982-04-01
A comprehensive review of existing basic diagnostic techniques applicable to the railcar roller bearing defect and failure problem was made. Of the potentially feasible diagnostic techniques identified, high frequency vibration was selected for exper...
On the diagnostic emulation technique and its use in the AIRLAB
NASA Technical Reports Server (NTRS)
Migneault, Gerard E.
1988-01-01
An aid is presented for understanding and judging the relevance of the diagnostic emulation technique to studies of highly reliable, digital computing systems for aircraft. A short review is presented of the need for and the use of the technique as well as an explanation of its principles of operation and implementation. Details that would be needed for operational control or modification of existing versions of the technique are not described.
Optical control and diagnostics sensors for gas turbine machinery
NASA Astrophysics Data System (ADS)
Trolinger, James D.; Jenkins, Thomas P.; Heeg, Bauke
2012-10-01
There exists a vast range of optical techniques that have been under development for solving complex measurement problems related to gas-turbine machinery and phenomena. For instance, several optical techniques are ideally suited for studying fundamental combustion phenomena in laboratory environments. Yet other techniques hold significant promise for use as either on-line gas turbine control sensors, or as health monitoring diagnostics sensors. In this paper, we briefly summarize these and discuss, in more detail, some of the latter class of techniques, including phosphor thermometry, hyperspectral imaging and low coherence interferometry, which are particularly suited for control and diagnostics sensing on hot section components with ceramic thermal barrier coatings (TBCs).
ERIC Educational Resources Information Center
Manning, S.; Dix, A.
2008-01-01
There is anecdotal evidence that a significant number of students studying computing related courses at degree level have difficulty with sub-GCE mathematics. Testing of students' skills is often performed using diagnostic tests and a number of computer-based diagnostic tests exist, which work, essentially, by testing one specific diagnostic skill…
Sahoo, Pravas Ranjan; Sethy, Kamadev; Mohapatra, Swagat; Panda, Debasis
2016-05-01
India being a developing country mainly depends on livestock sector for its economy. However, nowadays, there is emergence and reemergence of more transboundary animal diseases. The existing diagnostic techniques are not so quick and with less specificity. To reduce the economy loss, there should be a development of rapid, reliable, robust diagnostic technique, which can work with high degree of sensitivity and specificity. Loop mediated isothermal amplification assay is a rapid gene amplification technique that amplifies nucleic acid under an isothermal condition with a set of designed primers spanning eight distinct sequences of the target. This assay can be used as an emerging powerful, innovative gene amplification diagnostic tool against various pathogens of livestock diseases. This review is to highlight the basic concept and methodology of this assay in livestock disease.
Graph-based real-time fault diagnostics
NASA Technical Reports Server (NTRS)
Padalkar, S.; Karsai, G.; Sztipanovits, J.
1988-01-01
A real-time fault detection and diagnosis capability is absolutely crucial in the design of large-scale space systems. Some of the existing AI-based fault diagnostic techniques like expert systems and qualitative modelling are frequently ill-suited for this purpose. Expert systems are often inadequately structured, difficult to validate and suffer from knowledge acquisition bottlenecks. Qualitative modelling techniques sometimes generate a large number of failure source alternatives, thus hampering speedy diagnosis. In this paper we present a graph-based technique which is well suited for real-time fault diagnosis, structured knowledge representation and acquisition and testing and validation. A Hierarchical Fault Model of the system to be diagnosed is developed. At each level of hierarchy, there exist fault propagation digraphs denoting causal relations between failure modes of subsystems. The edges of such a digraph are weighted with fault propagation time intervals. Efficient and restartable graph algorithms are used for on-line speedy identification of failure source components.
Microwave holographic metrology for antenna diagnosis
NASA Astrophysics Data System (ADS)
Rahmat-Samii, Y.
1990-11-01
Advances in antenna diagnostic methodologies have been very significant in recent years. In particular, microwave holographic diagnostic techniques have been applied very successfully in improving the performance of reflector and array antennas. These techniques use the knowledge of the measured amplitude and phase of the antenna radiated fields and then take advantage of the existing Fourier transform relationships between the radiated fields and the effective aperture or current distribution to eventually determine the reflector surface or array excitation coefficients anomalies. In this paper an overview of the recent developments in applying microwave holography is presented. The theoretical, numerical and measurement aspects of this technique is detailed by providing representative results.
Development of advanced diagnostics for characterization of burning droplets in microgravity
NASA Technical Reports Server (NTRS)
Sankar, Subramanian; Buermann, Dale H.; Bachalo, William D.
1995-01-01
Diagnostic techniques currently used for microgravity research are generally not as advanced as those used in earth based gravity experiments. Diagnostic techniques for measuring the instantaneous radial temperature profile (or temperature gradients) within the burning droplet do not exist. Over the past few years, Aerometrics has been researching and developing a rainbow thermometric technique for measuring the droplet temperatures of burning droplets. This technique has recently been integrated with the phase Doppler interferometric technique to yield a diagnostic instrument that can be used to simultaneously measure the size, velocity, and temperature of burning droplets in complex spray flames. Also, the rainbow thermometric technique has been recently integrated with a point-diffraction interferometric technique for measuring the instantaneous gas phase temperature field surrounding a burning droplet. These research programs, apart from being very successful, have also helped us identify other innovative techniques for the characterization of burning droplets. For example, new techniques have been identified for measuring the instantaneous regression rate of burning droplets. Also, there is the possibility of extracting the instantaneous radial temperature distribution or the temperature gradients within a droplet during transient heating. What is important is that these diagnostic techniques have the potential for making use of inexpensive, light-weight, and rugged devices such as diode lasers and linear CCD arrays. As a result, they can be easily packaged for incorporation into microgravity drop-test and flight-test facilities. Furthermore, with the use of linear CCD arrays, data rates as high as 10-100 kHz can be easily achieved. This data rate is orders of magnitude higher than what is currently achievable. In this research and development program, a compact and rugged diagnostic system will be developed that can be used to measure instantaneous fuel droplet diameter, droplet regression rate, and the droplet internal temperature profiles or gradients at very high data rates in microgravity experiments.
Optical coherence tomography in gynecology: a narrative review
NASA Astrophysics Data System (ADS)
Kirillin, Mikhail; Motovilova, Tatiana; Shakhova, Natalia
2017-12-01
Modern gynecologic practice requires noninvasive diagnostics techniques capable of detecting morphological and functional alterations in tissues of female reproductive organs. Optical coherence tomography (OCT) is a promising tool for providing imaging of biotissues with high resolution at depths up to 2 mm. Design of the customized probes provides wide opportunities for OCT use in gynecology. This paper contains a retrospective insight into the history of OCT employment in gynecology, an overview of the existing gynecologic OCT probes, including those for combination with other diagnostic modalities, and state-of-the-art application of OCT for diagnostics of tumor and nontumor pathologies of female genitalia. Perspectives of OCT both in diagnostics and treatment planning and monitoring in gynecology are overviewed.
X-ray power and yield measurements at the refurbished Z machine
Jones, M. C.; Ampleford, D. J.; Cuneo, M. E.; ...
2014-08-04
Advancements have been made in the diagnostic techniques to measure accurately the total radiated x-ray yield and power from z-pinch loads at the Z Machine with high accuracy. The Z-accelerator is capable of outputting 2MJ and 330 TW of x-ray yield and power, and accurately measuring these quantities is imperative. We will describe work over the past several years which include the development of new diagnostics, improvements to existing diagnostics, and implementation of automated data analysis routines. A set of experiments were conducted on the Z machine where the load and machine configuration were held constant. During this shot series,more » it was observed that total z-pinch x-ray emission power determined from the two common techniques for inferring the x-ray power, Kimfol filtered x-ray diode diagnostic and the Total Power and Energy diagnostic gave 450 TW and 327 TW respectively. Our analysis shows the latter to be the more accurate interpretation. More broadly, the comparison demonstrates the necessity to consider spectral response and field of view when inferring xray powers from z-pinch sources.« less
Dande, Payal; Samant, Purva
2018-01-01
Tuberculosis [TB] has afflicted numerous nations in the world. As per a report by the World Health Organization [WHO], an estimated 1.4 million TB deaths in 2015 and an additional 0.4 million deaths resulting from TB disease among people living with HIV, were observed. Most of the TB deaths can be prevented if it is detected at an early stage. The existing processes of diagnosis like blood tests or sputum tests are not only tedious but also take a long time for analysis and cannot differentiate between different drug resistant stages of TB. The need to find newer prompt methods for disease detection has been aided by the latest Artificial Intelligence [AI] tools. Artificial Neural Network [ANN] is one of the important tools that is being used widely in diagnosis and evaluation of medical conditions. This review aims at providing brief introduction to various AI tools that are used in TB detection and gives a detailed description about the utilization of ANN as an efficient diagnostic technique. The paper also provides a critical assessment of ANN and the existing techniques for their diagnosis of TB. Researchers and Practitioners in the field are looking forward to use ANN and other upcoming AI tools such as Fuzzy-logic, genetic algorithms and artificial intelligence simulation as a promising current and future technology tools towards tackling the global menace of Tuberculosis. Latest advancements in the diagnostic field include the combined use of ANN with various other AI tools like the Fuzzy-logic, which has led to an increase in the efficacy and specificity of the diagnostic techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.
Diagnostic Evaluation of the Knee in the Office Setting Using Small-Bore Needle Arthroscopy.
Patel, Karan A; Hartigan, David E; Makovicka, Justin L; Dulle, Donald L; Chhabra, Anikar
2018-01-01
Arthroscopy is currently the gold standard for diagnosing intra-articular knee pathology. Magnetic resonance imaging (MRI) can be a clinical adjunct for diagnosis; however, it is not without its shortcomings. Although highly accurate, even advanced imaging misdiagnoses the condition in 1 in 14 patients with regard to anterior cruciate ligament pathology. Previous studies have indicated that MRI fails to identify meniscal pathology when one exists in 1 of every 10 cases, and diagnoses pathology when pathology truly does not exist in 1 of every 5 patients. In-office arthroscopy offers an alternative to formal diagnostic arthroscopy, with reduced cost and risk of complications. This is a technique article that discusses the use of small-bore needle arthroscopy in the office setting.
The use of pre-natal diagnostic techniques for sex selection: the Indian scene.
Kusum
1993-04-01
The use of pre-natal diagnostic techniques only for sex determination followed by termination of pregnancy on a finding of female foetus, is an atrocious and unethical practice. The bias against a female has been stretched further back: from cradle to grave, it is now from womb to the grave. One cannot however ignore the conditions of the society which breed and encourage such practices. A girl suffers neglect and discrimination right from childhood; she is tortured, harassed and maltreated after marriage. At the work place she is exploited. A widow or a divorcee is looked down upon by the family and the society. All these things make her life miserable and not worth existence....
Breast tumor malignancy modelling using evolutionary neural logic networks.
Tsakonas, Athanasios; Dounias, Georgios; Panagi, Georgia; Panourgias, Evangelia
2006-01-01
The present work proposes a computer assisted methodology for the effective modelling of the diagnostic decision for breast tumor malignancy. The suggested approach is based on innovative hybrid computational intelligence algorithms properly applied in related cytological data contained in past medical records. The experimental data used in this study were gathered in the early 1990s in the University of Wisconsin, based in post diagnostic cytological observations performed by expert medical staff. Data were properly encoded in a computer database and accordingly, various alternative modelling techniques were applied on them, in an attempt to form diagnostic models. Previous methods included standard optimisation techniques, as well as artificial intelligence approaches, in a way that a variety of related publications exists in modern literature on the subject. In this report, a hybrid computational intelligence approach is suggested, which effectively combines modern mathematical logic principles, neural computation and genetic programming in an effective manner. The approach proves promising either in terms of diagnostic accuracy and generalization capabilities, or in terms of comprehensibility and practical importance for the related medical staff.
Forceps biopsy and suction catheter for sampling in pulmonary nodules and infiltrates.
Peschke, Antje; Wiedemann, Bärbel; Höffken, Gert; Koschel, Dirk
2012-06-01
Transbronchial lung biopsy with forceps is a standard procedure in bronchoscopic tissue sampling. Suction catheter aspiration is another technique, but it is not widely known and almost no data exist regarding its diagnostic efficiency. 272 patients were included in a prospective and randomised study between February 2007 and October 2009. All were referred for bronchoscopic evaluation of pulmonary nodules/masses or infiltrates. We compared the diagnostic yield of forceps biopsy and suction catheter aspiration for a definite diagnosis and looked at whether such a diagnosis depends on the underlying pulmonary change. All patients underwent bronchoscopy with forceps biopsy and catheter aspiration. A definitive diagnosis was reached in a total of 183 (67.3%) patients, with catheter aspiration in 140 (51.5%) patients and with forceps biopsy in 136 (50.0%) patients. In 90 (33.1%) patients, a definite diagnosis could only be reached with the combination of both techniques. The diagnostic yield of forceps biopsy was better than catheter aspiration in infiltrates (p = 0.027), but was no different in nodules or masses (p = 0.09). Suction catheter aspiration is a useful technique of bronchoscopic tissue sampling. The combination of catheter aspiration and forceps biopsy results in a higher diagnostic yield than either method used alone.
Paper-based sample-to-answer molecular diagnostic platform for point-of-care diagnostics.
Choi, Jane Ru; Tang, Ruihua; Wang, ShuQi; Wan Abas, Wan Abu Bakar; Pingguan-Murphy, Belinda; Xu, Feng
2015-12-15
Nucleic acid testing (NAT), as a molecular diagnostic technique, including nucleic acid extraction, amplification and detection, plays a fundamental role in medical diagnosis for timely medical treatment. However, current NAT technologies require relatively high-end instrumentation, skilled personnel, and are time-consuming. These drawbacks mean conventional NAT becomes impractical in many resource-limited disease-endemic settings, leading to an urgent need to develop a fast and portable NAT diagnostic tool. Paper-based devices are typically robust, cost-effective and user-friendly, holding a great potential for NAT at the point of care. In view of the escalating demand for the low cost diagnostic devices, we highlight the beneficial use of paper as a platform for NAT, the current state of its development, and the existing challenges preventing its widespread use. We suggest a strategy involving integrating all three steps of NAT into one single paper-based sample-to-answer diagnostic device for rapid medical diagnostics in the near future. Copyright © 2015 Elsevier B.V. All rights reserved.
How can we maximize the diagnostic utility of uroflow?: ICI-RS 2017.
Gammie, Andrew; Rosier, Peter; Li, Rui; Harding, Chris
2018-01-09
To gauge the current level of diagnostic utility of uroflowmetry and to suggest areas needing research to improve this. A summary of the debate held at the 2017 meeting of the International Consultation on Incontinence Research Society, with subsequent analysis by the authors. Limited diagnostic sensitivity and specificity exist for maximum flow rates, multiple uroflow measurements, and flow-volume nomograms. There is a lack of clarity in flow rate curve shape description and uroflow time measurement. There is a need for research to combine uroflowmetry with other non-invasive indicators. Better standardizations of test technique, flow-volume nomograms, uroflow shape descriptions, and time measurements are required. © 2017 Wiley Periodicals, Inc.
Factory approach can streamline patient accounting.
Rands, J; Muench, M
1991-08-01
Although they may seem fundamentally different, similarities exist between operations of factories and healthcare organizations' business offices. As a result, a patient accounting approach based on manufacturing firms' management techniques may help smooth healthcare business processes. Receivables performance management incorporates the Japanese techniques of "just-in-time" and total quality management to reduce unbilled accounts and information backlog and accelerate payment. A preliminary diagnostic assessment of a patient accounting process helps identify bottlenecks and set priorities for work flow.
NASA Astrophysics Data System (ADS)
Smith, Roger J.
2008-10-01
A novel diagnostic technique for the remote and nonperturbative sensing of the local magnetic field in reactor relevant plasmas is presented. Pulsed polarimetry [Patent No. 12/150,169 (pending)] combines optical scattering with the Faraday effect. The polarimetric light detection and ranging (LIDAR)-like diagnostic has the potential to be a local Bpol diagnostic on ITER and can achieve spatial resolutions of millimeters on high energy density (HED) plasmas using existing lasers. The pulsed polarimetry method is based on nonlocal measurements and subtle effects are introduced that are not present in either cw polarimetry or Thomson scattering LIDAR. Important features include the capability of simultaneously measuring local Te, ne, and B∥ along the line of sight, a resiliency to refractive effects, a short measurement duration providing near instantaneous data in time, and location for real-time feedback and control of magnetohydrodynamic (MHD) instabilities and the realization of a widely applicable internal magnetic field diagnostic for the magnetic fusion energy program. The technique improves for higher neB∥ product and higher ne and is well suited for diagnosing the transient plasmas in the HED program. Larger devices such as ITER and DEMO are also better suited to the technique, allowing longer pulse lengths and thereby relaxing key technology constraints making pulsed polarimetry a valuable asset for next step devices. The pulsed polarimetry technique is clarified by way of illustration on the ITER tokamak and plasmas within the magnetized target fusion program within present technological means.
Controlling the Display of Capsule Endoscopy Video for Diagnostic Assistance
NASA Astrophysics Data System (ADS)
Vu, Hai; Echigo, Tomio; Sagawa, Ryusuke; Yagi, Keiko; Shiba, Masatsugu; Higuchi, Kazuhide; Arakawa, Tetsuo; Yagi, Yasushi
Interpretations by physicians of capsule endoscopy image sequences captured over periods of 7-8 hours usually require 45 to 120 minutes of extreme concentration. This paper describes a novel method to reduce diagnostic time by automatically controlling the display frame rate. Unlike existing techniques, this method displays original images with no skipping of frames. The sequence can be played at a high frame rate in stable regions to save time. Then, in regions with rough changes, the speed is decreased to more conveniently ascertain suspicious findings. To realize such a system, cue information about the disparity of consecutive frames, including color similarity and motion displacements is extracted. A decision tree utilizes these features to classify the states of the image acquisitions. For each classified state, the delay time between frames is calculated by parametric functions. A scheme selecting the optimal parameters set determined from assessments by physicians is deployed. Experiments involved clinical evaluations to investigate the effectiveness of this method compared to a standard-view using an existing system. Results from logged action based analysis show that compared with an existing system the proposed method reduced diagnostic time to around 32.5 ± minutes per full sequence while the number of abnormalities found was similar. As well, physicians needed less effort because of the systems efficient operability. The results of the evaluations should convince physicians that they can safely use this method and obtain reduced diagnostic times.
The motional stark effect with laser-induced fluorescence diagnostic
NASA Astrophysics Data System (ADS)
Foley, E. L.; Levinton, F. M.
2010-05-01
The motional Stark effect (MSE) diagnostic is the worldwide standard technique for internal magnetic field pitch angle measurements in magnetized plasmas. Traditionally, it is based on using polarimetry to measure the polarization direction of light emitted from a hydrogenic species in a neutral beam. As the beam passes through the magnetized plasma at a high velocity, in its rest frame it perceives a Lorentz electric field. This field causes the H-alpha emission to be split and polarized. A new technique under development adds laser-induced fluorescence (LIF) to a diagnostic neutral beam (DNB) for an MSE measurement that will enable radially resolved magnetic field magnitude as well as pitch angle measurements in even low-field (<1 T) experiments. An MSE-LIF system will be installed on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory. It will enable reconstructions of the plasma pressure, q-profile and current as well as, in conjunction with the existing MSE system, measurements of radial electric fields.
Block sparsity-based joint compressed sensing recovery of multi-channel ECG signals.
Singh, Anurag; Dandapat, Samarendra
2017-04-01
In recent years, compressed sensing (CS) has emerged as an effective alternative to conventional wavelet based data compression techniques. This is due to its simple and energy-efficient data reduction procedure, which makes it suitable for resource-constrained wireless body area network (WBAN)-enabled electrocardiogram (ECG) telemonitoring applications. Both spatial and temporal correlations exist simultaneously in multi-channel ECG (MECG) signals. Exploitation of both types of correlations is very important in CS-based ECG telemonitoring systems for better performance. However, most of the existing CS-based works exploit either of the correlations, which results in a suboptimal performance. In this work, within a CS framework, the authors propose to exploit both types of correlations simultaneously using a sparse Bayesian learning-based approach. A spatiotemporal sparse model is employed for joint compression/reconstruction of MECG signals. Discrete wavelets transform domain block sparsity of MECG signals is exploited for simultaneous reconstruction of all the channels. Performance evaluations using Physikalisch-Technische Bundesanstalt MECG diagnostic database show a significant gain in the diagnostic reconstruction quality of the MECG signals compared with the state-of-the art techniques at reduced number of measurements. Low measurement requirement may lead to significant savings in the energy-cost of the existing CS-based WBAN systems.
Smith, Roger J
2008-10-01
A novel diagnostic technique for the remote and nonperturbative sensing of the local magnetic field in reactor relevant plasmas is presented. Pulsed polarimetry [Patent No. 12/150,169 (pending)] combines optical scattering with the Faraday effect. The polarimetric light detection and ranging (LIDAR)-like diagnostic has the potential to be a local B(pol) diagnostic on ITER and can achieve spatial resolutions of millimeters on high energy density (HED) plasmas using existing lasers. The pulsed polarimetry method is based on nonlocal measurements and subtle effects are introduced that are not present in either cw polarimetry or Thomson scattering LIDAR. Important features include the capability of simultaneously measuring local T(e), n(e), and B(parallel) along the line of sight, a resiliency to refractive effects, a short measurement duration providing near instantaneous data in time, and location for real-time feedback and control of magnetohydrodynamic (MHD) instabilities and the realization of a widely applicable internal magnetic field diagnostic for the magnetic fusion energy program. The technique improves for higher n(e)B(parallel) product and higher n(e) and is well suited for diagnosing the transient plasmas in the HED program. Larger devices such as ITER and DEMO are also better suited to the technique, allowing longer pulse lengths and thereby relaxing key technology constraints making pulsed polarimetry a valuable asset for next step devices. The pulsed polarimetry technique is clarified by way of illustration on the ITER tokamak and plasmas within the magnetized target fusion program within present technological means.
2017-03-01
Use of non-ionizing radiation (NIR) for diagnostic purposes allows non-invasive assessment of the structure and function of the human body and is widely employed in medical care. ICNIRP has published previous statements about the protection of patients during medical magnetic resonance imaging (MRI), but diagnostic methods using other forms of NIR have not been considered. This statement reviews the range of diagnostic NIR devices currently used in clinical settings; documents the relevant regulations and policies covering patients and health care workers; reviews the evidence around potential health risks to patients and health care workers exposed to diagnostic NIR; and identifies situations of high NIR exposure from diagnostic devices in which patients or health care workers might not be adequately protected by current regulations. Diagnostic technologies were classified by the types of NIR that they employ. The aim was to describe the techniques in terms of general device categories which may encompass more specific devices or techniques with similar scientific principles. Relevant legally-binding regulations for protection of patients and workers and organizations responsible for those regulations were summarized. Review of the epidemiological evidence concerning health risks associated with exposure to diagnostic NIR highlighted a lack of data on potential risks to the fetus exposed to MRI during the first trimester, and on long-term health risks in workers exposed to MRI. Most of the relevant epidemiological evidence that is currently available relates to MRI or ultrasound. Exposure limits are needed for exposures from diagnostic technologies using optical radiation within the body. There is a lack of data regarding risk of congenital malformations following exposure to ultrasound in utero in the first trimester and also about the possible health effects of interactions between ultrasound and contrast media.
2017-01-01
Abstract Use of non-ionizing radiation (NIR) for diagnostic purposes allows non-invasive assessment of the structure and function of the human body and is widely employed in medical care. ICNIRP has published previous statements about the protection of patients during medical magnetic resonance imaging (MRI), but diagnostic methods using other forms of NIR have not been considered. This statement reviews the range of diagnostic NIR devices currently used in clinical settings; documents the relevant regulations and policies covering patients and health care workers; reviews the evidence around potential health risks to patients and health care workers exposed to diagnostic NIR; and identifies situations of high NIR exposure from diagnostic devices in which patients or health care workers might not be adequately protected by current regulations. Diagnostic technologies were classified by the types of NIR that they employ. The aim was to describe the techniques in terms of general device categories which may encompass more specific devices or techniques with similar scientific principles. Relevant legally-binding regulations for protection of patients and workers and organizations responsible for those regulations were summarized. Review of the epidemiological evidence concerning health risks associated with exposure to diagnostic NIR highlighted a lack of data on potential risks to the fetus exposed to MRI during the first trimester, and on long-term health risks in workers exposed to MRI. Most of the relevant epidemiological evidence that is currently available relates to MRI or ultrasound. Exposure limits are needed for exposures from diagnostic technologies using optical radiation within the body. There is a lack of data regarding risk of congenital malformations following exposure to ultrasound in utero in the first trimester and also about the possible health effects of interactions between ultrasound and contrast media. PMID:28121732
Computer Aided Diagnostic Support System for Skin Cancer: A Review of Techniques and Algorithms
Masood, Ammara; Al-Jumaily, Adel Ali
2013-01-01
Image-based computer aided diagnosis systems have significant potential for screening and early detection of malignant melanoma. We review the state of the art in these systems and examine current practices, problems, and prospects of image acquisition, pre-processing, segmentation, feature extraction and selection, and classification of dermoscopic images. This paper reports statistics and results from the most important implementations reported to date. We compared the performance of several classifiers specifically developed for skin lesion diagnosis and discussed the corresponding findings. Whenever available, indication of various conditions that affect the technique's performance is reported. We suggest a framework for comparative assessment of skin cancer diagnostic models and review the results based on these models. The deficiencies in some of the existing studies are highlighted and suggestions for future research are provided. PMID:24575126
Reiman, Michael P; Thorborg, Kristian; Goode, Adam P; Cook, Chad E; Weir, Adam; Hölmich, Per
2017-09-01
Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Summarize and evaluate the diagnostic accuracy and clinical utility of various imaging modalities and injection techniques relevant to hip FAI/ALT. Systematic review with meta-analysis. A computer-assisted literature search was conducted of MEDLINE, CINAHL, and EMBASE databases using keywords related to diagnostic accuracy of hip joint pathologic changes. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were used for the search and reporting phases of the study. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies (QUADAS) tool. Random effects models were used to summarize sensitivities (SN), specificities (SP), likelihood ratios (+LR and -LR), diagnostic odds ratios (DOR), and respective confidence intervals (CI). The search strategy and assessment for risk of bias revealed 25 articles scoring above 10/14 on the items of the QUADAS. Four studies investigated FAI, and the data were not pooled. Twenty articles on ALT qualified for meta-analysis. Pretest probability of ALT in the studies in this review was 81% (72%-88%), while the pretest probability of FAI diagnosis was 74% (95% CI, 51%-91%). The meta-analysis showed that computed tomography arthrography (CTA) demonstrated the strongest overall diagnostic accuracy: pooled SN 0.91 (95% CI, 0.83-0.96); SP 0.89 (95% CI, 0.74-0.97); +LR 6.28 (95% CI, 2.78-14.21); -LR 0.11 (95% CI, 0.06-0.21); and DOR 64.38 (95% CI, 19.17-216.21). High pretest probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US) and by a moderate degree for CTA. Negative imaging findings decreased the probability that a labral tear existed by a minimal degree with the use of MRI and US, a small to moderate degree with MRA, and a moderate degree with CTA. Although findings of the included studies suggested potentially favorable use of these modalities for the diagnosis of ALT and FAI, our results suggest that these findings have limited generalizability and clinical utility given very high pretest prevalence, large confidence intervals, and selection criteria of the studies. Registration: PROSPERO Registration #CRD42015027745.
A study of the electromagnetic interaction between planetary bodies and the solar wind
NASA Technical Reports Server (NTRS)
Schwartz, K.
1971-01-01
Theoretical and computational techniques were developed for calculating the time dependent electromagnetic response of a radially inhomogeneous moon. The techniques were used to analyze the experimental data from the LSM (lunar surface magnetometer) thus providing an in-depth diagnostic of the Lunar interior. The theory was also incorporated into an existing computer code designed to calculate the thermal evolution of planetary bodies. The program will provide a tool for examining the effect of heating from the TE mode (poloidal magnetic field) as well as the TM mode (toroidal magnetic field).
Non-contact temperature measurements in support of microgravity combustion experiments
NASA Technical Reports Server (NTRS)
Greenberg, Paul S.
1989-01-01
Recent conceptual advances in the understanding of combustion science fundamentals in the context of microgravity processes and phenomenology have resulted in an increased demand for diagnostic systems of greater sophistication. Owing primarily to the severe operational constraints that accompany the space flight environment, measurement systems to date remain fairly primative in nature. Qualitative pictures provided by photographic recording media comprise the majority of the existing data, the remainder consisting of the output of conventional transducers, such as thermocouples, hot wires, and pressure transducers. The absence of the rather strong influence of buoyant convection renders microgravity combustion phenomena more fragile than their 1-G counterparts. The emphasis was placed on nonperturbing optical diagnostics. Other factors such as limited supplies of expendable reactants, and periods of microgravity time of sufficient duration, coupled with more fundamental questions regarding inherent length and time scales and reproducibility have favored multipoint or multidimensional techniques. While the development of optical diagnostics for application to combustion science is an extremely active area at present, the peculiarities of space flight hardware severely restrict the feasibility of implementing the majority of techniques which are being utilized in terrestrial applications. The additional requirements for system reliability and operational simplicity have tended to promote somewhat less commonly emphasized techniques such as refractive index mapping and molecular Rayleigh scattering, which are briefly discussed.
Food allergy--fact or fiction: a review.
Finn, R
1992-01-01
Food sensitivity is a common condition presenting with various clinical syndromes including migraine, urticaria, gluten enteropathy, Crohn's disease and irritable bowel syndrome. It is a heterogeneous condition affecting different organ systems and is also aetiologically diverse with subgroups due to allergy, pharmacological reactions, enzyme deficiencies and psychological causes. Clinical acceptance of food sensitivity has been delayed by the use of dubious diagnostic techniques by a minority of practitioners and the lack of laboratory diagnostic tests, but several double blind studies have now fully validated the existence of food sensitivity syndromes. More widespread recognition of food sensitivity would be cost effective for the National Health Service. PMID:1433127
Pneumonia Updates on Legionella, Chlamydophila, and Mycoplasma Pneumonia
Sharma, Lokesh; Losier, Ashley; Tolbert, Thomas; Dela Cruz, Charles S.; Marion, Chad R.
2017-01-01
SUMMARY CAP due to Legionella, Chlamydophyla, or Mycoplasma continues to be a diagnostic challenge due to the nonspecific clinical and radiographic presentations. The vague clinical presentations of atypical CAP contribute to its underdiagnosis and under-reporting. Advancements in diagnostic techniques bring hope to rapid and accurate diagnosis of atypical CAP. Macrolides and respiratory fluoroquinolones are currently the antibiotics of choice, but this may change in the near future as more antibiotics resistance patterns emerge for atypical CAP. Several controversies still exist in atypical CAP, underscoring the need for continued investigation of preventing atypical CAP and determine its association with chronic lung diseases. PMID:28159161
NASA Technical Reports Server (NTRS)
Shen, Ji Y.; Sharpe, Lonnie, Jr.
1998-01-01
The research activity for this project is mainly to investigate the necessity and feasibility to develop a structural health monitoring system for rocket engines, and to carry out a research plan for further development of the system. More than one hundred technical papers have been searched and reviewed during the period. We concluded after this investigation that adding a new module in NASA's existing automated diagnostic system to monitor the healthy condition of rocket engine structures is a crucial task, and it's possible to develop such a system based upon the vibrational-based nondestructive damage assessment techniques. A number of such techniques have been introduced. Their advantages and disadvantages are also discussed. A global research plan has been figured out. As the first step of the overall research plan, a proposal for the next fiscal year has been submitted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, Kevin L.
The purpose of this LDRD project was to demonstrate high spatial and temporal resolution x-ray imaging using optical detectors, and in particular the VISAR and OHRV diagnostics on the OMEGA laser. The x-ray source being imaged was a backlighter capsule being imploded by 39 beams of the OMEGA laser. In particular this approach utilized a semiconductor with the side facing the backlighter capsule coated with a thin aluminum layer to allow x rays to pass through the metal layer and then get absorbed in the semiconductor. The other side of the semiconductor was AR coated to allow the VISAR ormore » OHRV probe beam to sample the phase change of the semiconductor as the x rays were absorbed in the semiconductor. This technique is capable of acquiring sub-picosecond 2-D or 1-D x-ray images, detector spatial resolution of better than 10 um and the ability to operate in a high neutron flux environment expected on ignition shots with burning plasmas. In addition to demonstrating this technique on the OMEGA laser, several designs were made to improve the phase sensitivity, temporal resolution and number of frames over the existing diagnostics currently implemented on the OMEGA laser. These designs included both 2-d imaging diagnostics as well as improved 1-D imaging diagnostics which were streaked in time.« less
When Medicine Meets Engineering—Paradigm Shifts in Diagnostics and Therapeutics
Wang, Hann; Silva, Aleidy; Ho, Chih-Ming
2013-01-01
During the last two decades, the manufacturing techniques of microfluidics-based devices have been phenomenally advanced, offering unlimited potential for bio-medical technologies. However, the direct applications of these technologies toward diagnostics and therapeutics are still far from maturity. The present challenges lay at the interfaces between the engineering systems and the biocomplex systems. A precisely designed engineering system with narrow dynamic range is hard to seamlessly integrate with the adaptive biological system in order to achieve the design goals. These differences remain as the roadblock between two fundamentally non-compatible systems. This paper will not extensively review the existing microfluidic sensors and actuators; rather, we will discuss the sources of the gaps for integration. We will also introduce system interface technologies for bridging the differences to lead toward paradigm shifts in diagnostics and therapeutics. PMID:26835672
Neural net diagnostics for VLSI test
NASA Technical Reports Server (NTRS)
Lin, T.; Tseng, H.; Wu, A.; Dogan, N.; Meador, J.
1990-01-01
This paper discusses the application of neural network pattern analysis algorithms to the IC fault diagnosis problem. A fault diagnostic is a decision rule combining what is known about an ideal circuit test response with information about how it is distorted by fabrication variations and measurement noise. The rule is used to detect fault existence in fabricated circuits using real test equipment. Traditional statistical techniques may be used to achieve this goal, but they can employ unrealistic a priori assumptions about measurement data. Our approach to this problem employs an adaptive pattern analysis technique based on feedforward neural networks. During training, a feedforward network automatically captures unknown sample distributions. This is important because distributions arising from the nonlinear effects of process variation can be more complex than is typically assumed. A feedforward network is also able to extract measurement features which contribute significantly to making a correct decision. Traditional feature extraction techniques employ matrix manipulations which can be particularly costly for large measurement vectors. In this paper we discuss a software system which we are developing that uses this approach. We also provide a simple example illustrating the use of the technique for fault detection in an operational amplifier.
Zardi, Enrico Maria; Di Matteo, Francesco Maria; Pacella, Claudio Maurizio; Sanyal, Arun J
2016-01-01
Portal hypertension is a severe syndrome that may derive from pre-sinusoidal, sinusoidal and post-sinusoidal causes. As a consequence, several complications (i.e., ascites, oesophageal varices) may develop. In sinusoidal portal hypertension, hepatic venous pressure gradient (HVPG) is a reliable method for defining the grade of portal pressure, establishing the effectiveness of the treatment and predicting the occurrence of complications; however, some questions exist regarding its ability to discriminate bleeding from nonbleeding varices in cirrhotic patients. Other imaging techniques (transient elastography, endoscopy, endosonography and duplex Doppler sonography) for assessing causes and complications of portal hypertensive syndrome are available and may be valuable for the management of these patients. In this review, we evaluate invasive and non-invasive techniques currently employed to obtain a clinical prediction of deadly complications, such as variceal bleeding in patients affected by sinusoidal portal hypertension, in order to create a diagnostic algorithm to manage them. Again, HVPG appears to be the reference standard to evaluate portal hypertension and monitor the response to treatment, but its ability to predict several complications and support management decisions might be further improved through the diagnostic combination with other imaging techniques. PMID:24328372
Zardi, Enrico Maria; Di Matteo, Francesco Maria; Pacella, Claudio Maurizio; Sanyal, Arun J
2014-02-01
Portal hypertension is a severe syndrome that may derive from pre-sinusoidal, sinusoidal, and post-sinusoidal causes. As a consequence, several complications (i.e. ascites, oesophageal varices) may develop. In sinusoidal portal hypertension, hepatic venous pressure gradient (HVPG) is a reliable method for defining the grade of portal pressure, establishing the effectiveness of the treatment, and predicting the occurrence of complications; however, some questions exist regarding its ability to discriminate bleeding from non-bleeding varices in cirrhotic patients. Other imaging techniques (transient elastography, endoscopy, endosonography, and duplex Doppler sonography) for assessing causes and complications of portal hypertensive syndrome are available and may be valuable for the management of these patients. In this review, we evaluate invasive and non-invasive techniques currently employed to obtain a clinical prediction of deadly complications, such as variceal bleeding in patients affected by sinusoidal portal hypertension, in order to create a diagnostic algorithm to manage them. Again, HVPG appears to be the reference standard to evaluate portal hypertension and monitor the response to treatment, but its ability to predict several complications and support management decisions might be further improved through the diagnostic combination with other imaging techniques.
Expansion Mini-Microscopy: An Enabling Alternative in Point-of-Care Diagnostics
Zhang, Yu Shrike; Santiago, Grissel Trujillo-de; Alvarez, Mario Moisés; Schiff, Steven J.; Boyden, Edward S.; Khademhosseini, Ali
2017-01-01
Diagnostics play a significant role in health care. In the developing world and low-resource regions the utility for point-of-care (POC) diagnostics becomes even greater. This need has long been recognized, and diagnostic technology has seen tremendous progress with the development of portable instrumentation such as miniature imagers featuring low complexity and cost. However, such inexpensive devices have not been able to achieve a resolution sufficient for POC detection of pathogens at very small scales, such as single-cell parasites, bacteria, fungi, and viruses. To this end, expansion microscopy (ExM) is a recently developed technique that, by physically expanding preserved biological specimens through a chemical process, enables super-resolution imaging on conventional microscopes and improves imaging resolution of a given microscope without the need to modify the existing microscope hardware. Here we review recent advances in ExM and portable imagers, respectively, and discuss the rational combination of the two technologies, that we term expansion mini-microscopy (ExMM). In ExMM, the physical expansion of a biological sample followed by imaging on a mini-microscope achieves a resolution as high as that attainable by conventional high-end microscopes imaging non-expanded samples, at significant reduction in cost. We believe that this newly developed ExMM technique is likely to find widespread applications in POC diagnostics in resource-limited and remote regions by expanded-scale imaging of biological specimens that are otherwise not resolvable using low-cost imagers. PMID:29062977
2013-01-01
Background Persistent digestive disorders account for considerable disease burden in the tropics. Despite advances in understanding acute gastrointestinal infections, important issues concerning epidemiology, diagnosis, treatment and control of most persistent digestive symptomatologies remain to be elucidated. Helminths and intestinal protozoa are considered to play major roles, but the full extent of the aetiologic spectrum is still unclear. We provide an overview of pathogens causing digestive disorders in the tropics and evaluate available reference tests. Methods We searched the literature to identify pathogens that might give rise to persistent diarrhoea, chronic abdominal pain and/or blood in the stool. We reviewed existing laboratory diagnostic methods for each pathogen and stratified them by (i) microscopy; (ii) culture techniques; (iii) immunological tests; and (iv) molecular methods. Pathogen-specific reference tests providing highest diagnostic accuracy are described in greater detail. Results Over 30 pathogens may cause persistent digestive disorders. Bacteria, viruses and parasites are important aetiologic agents of acute and long-lasting symptomatologies. An integrated approach, consisting of stool culture, microscopy and/or specific immunological techniques for toxin, antigen and antibody detection, is required for accurate diagnosis of bacteria and parasites. Molecular techniques are essential for sensitive diagnosis of many viruses, bacteria and intestinal protozoa, and are increasingly utilised as adjuncts for helminth identification. Conclusions Diagnosis of the broad spectrum of intestinal pathogens is often cumbersome. There is a need for rapid diagnostic tests that are simple and affordable for resource-constrained settings, so that the management of patients suffering from persistent digestive disorders can be improved. PMID:23347408
Hyperspectral imaging for detection of arthritis: feasibility and prospects
NASA Astrophysics Data System (ADS)
Milanic, Matija; Paluchowski, Lukasz A.; Randeberg, Lise L.
2015-09-01
Rheumatoid arthritis (RA) is a disease that frequently leads to joint destruction. It has a high incidence rate worldwide, and the disease significantly reduces patients' quality of life. Detecting and treating inflammatory arthritis before structural damage to the joint has occurred is known to be essential for preventing patient disability and pain. Existing diagnostic technologies are expensive, time consuming, and require trained personnel to collect and interpret data. Optical techniques might be a fast, noninvasive alternative. Hyperspectral imaging (HSI) is a noncontact optical technique which provides both spectral and spatial information in one measurement. In this study, the feasibility of HSI in arthritis diagnostics was explored by numerical simulations and optimal imaging parameters were identified. Hyperspectral reflectance and transmission images of RA and normal human joint models were simulated using the Monte Carlo method. The spectral range was 600 to 1100 nm. Characteristic spatial patterns for RA joints and two spectral windows with transmission were identified. The study demonstrated that transmittance images of human joints could be used as one parameter for discrimination between arthritic and unaffected joints. The presented work shows that HSI is a promising imaging modality for the diagnostics and follow-up monitoring of arthritis in small joints.
NASA Technical Reports Server (NTRS)
Oeftering, Richard C.; Wade, Raymond P.; Izadnegahdar, Alain
2011-01-01
The Component-Level Electronic-Assembly Repair (CLEAR) project at the NASA Glenn Research Center is aimed at developing technologies that will enable space-flight crews to perform in situ component-level repair of electronics on Moon and Mars outposts, where there is no existing infrastructure for logistics spares. These technologies must provide effective repair capabilities yet meet the payload and operational constraints of space facilities. Effective repair depends on a diagnostic capability that is versatile but easy to use by crew members that have limited training in electronics. CLEAR studied two techniques that involve extensive precharacterization of "known good" circuits to produce graphical signatures that provide an easy-to-use comparison method to quickly identify faulty components. Analog Signature Analysis (ASA) allows relatively rapid diagnostics of complex electronics by technicians with limited experience. Because of frequency limits and the growing dependence on broadband technologies, ASA must be augmented with other capabilities. To meet this challenge while preserving ease of use, CLEAR proposed an alternative called Complex Signature Analysis (CSA). Tests of ASA and CSA were used to compare capabilities and to determine if the techniques provided an overlapping or complementary capability. The results showed that the methods are complementary.
White, Brad J; Goehl, Dan R; Amrine, David E; Booker, Calvin; Wildman, Brian; Perrett, Tye
2016-04-01
Accurate diagnosis of bovine respiratory disease (BRD) in beef cattle is a critical facet of therapeutic programs through promotion of prompt treatment of diseased calves in concert with judicious use of antimicrobials. Despite the known inaccuracies, visual observation (VO) of clinical signs is the conventional diagnostic modality for BRD diagnosis. Objective methods of remotely monitoring cattle wellness could improve diagnostic accuracy; however, little information exists describing the accuracy of this method compared to traditional techniques. The objective of this research is to employ Bayesian methodology to elicit diagnostic characteristics of conventional VO compared to remote early disease identification (REDI) to diagnose BRD. Data from previous literature on the accuracy of VO were combined with trial data consisting of direct comparison between VO and REDI for BRD in two populations. No true gold standard diagnostic test exists for BRD; therefore, estimates of diagnostic characteristics of each test were generated using Bayesian latent class analysis. Results indicate a 90.0% probability that the sensitivity of REDI (median 81.3%; 95% probability interval [PI]: 55.5, 95.8) was higher than VO sensitivity (64.5%; PI: 57.9, 70.8). The specificity of REDI (median 92.9%; PI: 88.2, 96.9) was also higher compared to VO (median 69.1%; PI: 66.3, 71.8). The differences in sensitivity and specificity resulted in REDI exhibiting higher positive and negative predictive values in both high (41.3%) and low (2.6%) prevalence situations. This research illustrates the potential of remote cattle monitoring to augment conventional methods of BRD diagnosis resulting in more accurate identification of diseased cattle. Copyright © 2016 Elsevier B.V. All rights reserved.
Dielectrophoresis-based microfluidic platforms for cancer diagnostics.
Chan, Jun Yuan; Ahmad Kayani, Aminuddin Bin; Md Ali, Mohd Anuar; Kok, Chee Kuang; Yeop Majlis, Burhanuddin; Hoe, Susan Ling Ling; Marzuki, Marini; Khoo, Alan Soo-Beng; Ostrikov, Kostya Ken; Ataur Rahman, Md; Sriram, Sharath
2018-01-01
The recent advancement of dielectrophoresis (DEP)-enabled microfluidic platforms is opening new opportunities for potential use in cancer disease diagnostics. DEP is advantageous because of its specificity, low cost, small sample volume requirement, and tuneable property for microfluidic platforms. These intrinsic advantages have made it especially suitable for developing microfluidic cancer diagnostic platforms. This review focuses on a comprehensive analysis of the recent developments of DEP enabled microfluidic platforms sorted according to the target cancer cell. Each study is critically analyzed, and the features of each platform, the performance, added functionality for clinical use, and the types of samples, used are discussed. We address the novelty of the techniques, strategies, and design configuration used in improving on existing technologies or previous studies. A summary of comparing the developmental extent of each study is made, and we conclude with a treatment of future trends and a brief summary.
Photoacoustic spectroscopic differences between normal and malignant thyroid tissues
NASA Astrophysics Data System (ADS)
Li, Li; Xie, Wengming; Li, Hui
2012-12-01
The thyroid is one of the main endocrine glands of human body, which plays a crucial role in the body's metabolism. Thyroid cancer mortality ranks only second to ovarian cancer in endocrine cancer. Routine diagnostic methods of thyroid diseases in present clinic exist misdiagnosis and missed diagnosis to varying degrees. Those lead to miss the best period of cancer treatment--early. Photoacoustic spectroscopy technology is a new tool, which provides an effective and noninvasive way for biomedical materials research, being highly sensitive and without sample pretreatment. In this paper, we use photoacoustic spectroscopy technology (PAST) to detect the absorption spectrum between normal and malignant thyroid tissues. The result shows that the photoacoustic spectroscopy technology (PAST) could differentiate malignant thyroid tissue from normal thyroid tissue very well. This technique combined with routine diagnostic methods has the potential to increase the diagnostic accuracy in clinical thyroid cancer diagnosis.
Radiometry in medicine and biology
NASA Astrophysics Data System (ADS)
Nahm, Kie-Bong; Choi, Eui Y.
2012-10-01
Diagnostics in medicine plays a critical role in helping medical professionals deliver proper diagnostic decisions. Most samples in this trade are of the human origin and a great portion of methodologies practiced in biology labs is shared in clinical diagnostic laboratories as well. Most clinical tests are quantitative in nature and recent increase in interests in preventive medicine requires the determination of minimal concentration of target analyte: they exist in small quantities at the early stage of various diseases. Radiometry or the use of optical radiation is the most trusted and reliable means of converting biologic concentrations into quantitative physical quantities. Since optical energy is readily available in varying energies (or wavelengths), the appropriate combination of light and the sample absorption properties provides reliable information about the sample concentration through Beer-Lambert law to a decent precision. In this article, the commonly practiced techniques in clinical and biology labs are reviewed from the standpoint of radiometry.
NASA Technical Reports Server (NTRS)
Vial, J. C.
1986-01-01
The structure of prominences and the diagnostic techniques used to evaluate their physical parameters are discussed. These include electron temperature, various densities (n sub p, n sub e, n sub l), ionization degree, velocities, and magnetic field vector. UV and radio measurements have already evidenced the existence of different temperature regions, corresponding to different geometrical locations, e.g., the so called Prominence-Corona (P-C) interface. Velocity measurements are important for considering formation and mass balance of prominences but there are conflicting velocity measurements which have led to the basic question: what structure is actually observed at a given wavelength; what averaging is performed within the projected slit area during the exposure time? In optically thick lines, the question of the formation region of the radiation along the line of sight is also not a trivial one. The same is true for low resolution measurements of the magnetic field. Coupling diagnostics with structure is now a general preoccupation.
Woodward, Tony M
2009-02-01
Dental radiology is the core diagnostic modality of veterinary dentistry. Dental radiographs assist in detecting hidden painful pathology, estimating the severity of dental conditions, assessing treatment options, providing intraoperative guidance, and also serve to monitor success of prior treatments. Unfortunately, most professional veterinary training programs provide little or no training in veterinary dentistry in general or dental radiology in particular. Although a technical learning curve does exist, the techniques required for producing diagnostic films are not difficult to master. Regular use of dental x-rays will increase the amount of pathology detected, leading to healthier patients and happier clients who notice a difference in how their pet feels. This article covers equipment and materials needed to produce diagnostic intraoral dental films. A simplified guide for positioning will be presented, including a positioning "cheat sheet" to be placed next to the dental x-ray machine in the operatory. Additionally, digital dental radiograph systems will be described and trends for their future discussed.
Magnostics: Image-Based Search of Interesting Matrix Views for Guided Network Exploration.
Behrisch, Michael; Bach, Benjamin; Hund, Michael; Delz, Michael; Von Ruden, Laura; Fekete, Jean-Daniel; Schreck, Tobias
2017-01-01
In this work we address the problem of retrieving potentially interesting matrix views to support the exploration of networks. We introduce Matrix Diagnostics (or Magnostics), following in spirit related approaches for rating and ranking other visualization techniques, such as Scagnostics for scatter plots. Our approach ranks matrix views according to the appearance of specific visual patterns, such as blocks and lines, indicating the existence of topological motifs in the data, such as clusters, bi-graphs, or central nodes. Magnostics can be used to analyze, query, or search for visually similar matrices in large collections, or to assess the quality of matrix reordering algorithms. While many feature descriptors for image analyzes exist, there is no evidence how they perform for detecting patterns in matrices. In order to make an informed choice of feature descriptors for matrix diagnostics, we evaluate 30 feature descriptors-27 existing ones and three new descriptors that we designed specifically for MAGNOSTICS-with respect to four criteria: pattern response, pattern variability, pattern sensibility, and pattern discrimination. We conclude with an informed set of six descriptors as most appropriate for Magnostics and demonstrate their application in two scenarios; exploring a large collection of matrices and analyzing temporal networks.
Photonic Doppler Velocimetry Multiplexing Techniques: Evaluation of Photonic Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edward Daykin
This poster reports progress related to photonic technologies. Specifically, the authors developed diagnostic system architecture for a Multiplexed Photonic Doppler Velocimetry (MPDV) that incorporates frequency and time-division multiplexing into existing PDV methodology to provide increased channel count. Current MPDV design increases number of data records per digitizer channel 8x, and also operates as a laser-safe (Class 3a) system. Further, they applied heterodyne interferometry to allow for direction-of-travel determination and enable high-velocity measurements (>10 km/s) via optical downshifting. They also leveraged commercially available, inexpensive and robust components originally developed for telecom applications. Proposed MPDV architectures employ only commercially available, fiber-coupled hardware.
Theurer, M E; White, B J; Larson, R L; Schroeder, T C
2015-03-01
Bovine respiratory disease is an economically important syndrome in the beef industry, and diagnostic accuracy is important for optimal disease management. The objective of this study was to determine whether improving diagnostic sensitivity or specificity was of greater economic value at varied levels of respiratory disease prevalence by using Monte Carlo simulation. Existing literature was used to populate model distributions of published sensitivity, specificity, and performance (ADG, carcass weight, yield grade, quality grade, and mortality risk) differences among calves based on clinical respiratory disease status. Data from multiple cattle feeding operations were used to generate true ranges of respiratory disease prevalence and associated mortality. Input variables were combined into a single model that calculated estimated net returns for animals by diagnostic category (true positive, false positive, false negative, and true negative) based on the prevalence, sensitivity, and specificity for each iteration. Net returns for each diagnostic category were multiplied by the proportion of animals in each diagnostic category to determine group profitability. Apparent prevalence was categorized into low (<15%) and high (≥15%) groups. For both apparent prevalence categories, increasing specificity created more rapid, positive change in net returns than increasing sensitivity. Improvement of diagnostic specificity, perhaps through a confirmatory test interpreted in series or pen-level diagnostics, can increase diagnostic value more than improving sensitivity. Mortality risk was the primary driver for net returns. The results from this study are important for determining future research priorities to analyze diagnostic techniques for bovine respiratory disease and provide a novel way for modeling diagnostic tests.
Dynamic diagnostics of the error fields in tokamaks
NASA Astrophysics Data System (ADS)
Pustovitov, V. D.
2007-07-01
The error field diagnostics based on magnetic measurements outside the plasma is discussed. The analysed methods rely on measuring the plasma dynamic response to the finite-amplitude external magnetic perturbations, which are the error fields and the pre-programmed probing pulses. Such pulses can be created by the coils designed for static error field correction and for stabilization of the resistive wall modes, the technique developed and applied in several tokamaks, including DIII-D and JET. Here analysis is based on the theory predictions for the resonant field amplification (RFA). To achieve the desired level of the error field correction in tokamaks, the diagnostics must be sensitive to signals of several Gauss. Therefore, part of the measurements should be performed near the plasma stability boundary, where the RFA effect is stronger. While the proximity to the marginal stability is important, the absolute values of plasma parameters are not. This means that the necessary measurements can be done in the diagnostic discharges with parameters below the nominal operating regimes, with the stability boundary intentionally lowered. The estimates for ITER are presented. The discussed diagnostics can be tested in dedicated experiments in existing tokamaks. The diagnostics can be considered as an extension of the 'active MHD spectroscopy' used recently in the DIII-D tokamak and the EXTRAP T2R reversed field pinch.
Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review.
Holm, Anne; Aabenhus, Rune
2016-06-08
Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection in primary care. The aim of this study was to determine the accuracy of urine culture from different sampling-techniques in symptomatic non-pregnant women in primary care. A systematic review was conducted by searching Medline and Embase for clinical studies conducted in primary care using a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. We included seven studies investigating urine sampling technique in 1062 symptomatic patients in primary care. Mid-stream-clean-catch had a positive predictive value of 0.79 to 0.95 and a negative predictive value close to 1 compared to sterile techniques. Two randomized controlled trials found no difference in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However, the evidence presented is in-direct and the difference between mid-stream-clean-catch, mid-stream-urine and random samples remains to be investigated in a paired design to verify the present findings.
Differential white cell count by centrifugal microfluidics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.
We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generationmore » of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.« less
NASA Astrophysics Data System (ADS)
Lloyd, G. R.; Nallala, J.; Stone, N.
2016-03-01
FTIR is a well-established technique and there is significant interest in applying this technique to medical diagnostics e.g. to detect cancer. The introduction of focal plane array (FPA) detectors means that FTIR is particularly suited to rapid imaging of biopsy sections as an adjunct to digital pathology. Until recently however each pixel in the image has been limited to a minimum of 5.5 µm which results in a comparatively low magnification image or histology applications and potentially the loss of important diagnostic information. The recent introduction of higher magnification optics gives image pixels that cover approx. 1.1 µm. This reduction in image pixel size gives images of higher magnification and improved spatial detail can be observed. However, the effect of increasing the magnification on spectral quality and the ability to discriminate between disease states is not well studied. In this work we test the discriminatory performance of FTIR imaging using both standard (5.5 µm) and high (1.1 µm) magnification for the detection of colorectal cancer and explore the effect of binning to degrade high resolution images to determine whether similar diagnostic information and performance can be obtained using both magnifications. Results indicate that diagnostic performance using high magnification may be reduced as compared to standard magnification when using existing multivariate approaches. Reduction of the high magnification data to standard magnification via binning can potentially recover some of the lost performance.
Oloumi, Faraz; Rangayyan, Rangaraj M.; Ells, Anna L.
2016-01-01
Abstract. Retinopathy of prematurity (ROP), a disorder of the retina occurring in preterm infants, is the leading cause of preventable childhood blindness. An active phase of ROP that requires treatment is associated with the presence of plus disease, which is diagnosed clinically in a qualitative manner by visual assessment of the existence of a certain level of increase in the thickness and tortuosity of retinal vessels. The present study performs computer-aided diagnosis (CAD) of plus disease via quantitative measurement of tortuosity in retinal fundus images of preterm infants. Digital image processing techniques were developed for the detection of retinal vessels and measurement of their tortuosity. The total lengths of abnormally tortuous vessels in each quadrant and the entire image were then computed. A minimum-length diagnostic-decision-making criterion was developed to assess the diagnostic sensitivity and specificity of the values obtained. The area (Az) under the receiver operating characteristic curve was used to assess the overall diagnostic accuracy of the methods. Using a set of 19 retinal fundus images of preterm infants with plus disease and 91 without plus disease, the proposed methods provided an overall diagnostic accuracy of Az=0.98. Using the total length of all abnormally tortuous vessel segments in an image, our techniques are capable of CAD of plus disease with high accuracy without the need for manual selection of vessels to analyze. The proposed methods may be used in a clinical or teleophthalmological setting. PMID:28018938
Using decision-tree classifier systems to extract knowledge from databases
NASA Technical Reports Server (NTRS)
St.clair, D. C.; Sabharwal, C. L.; Hacke, Keith; Bond, W. E.
1990-01-01
One difficulty in applying artificial intelligence techniques to the solution of real world problems is that the development and maintenance of many AI systems, such as those used in diagnostics, require large amounts of human resources. At the same time, databases frequently exist which contain information about the process(es) of interest. Recently, efforts to reduce development and maintenance costs of AI systems have focused on using machine learning techniques to extract knowledge from existing databases. Research is described in the area of knowledge extraction using a class of machine learning techniques called decision-tree classifier systems. Results of this research suggest ways of performing knowledge extraction which may be applied in numerous situations. In addition, a measurement called the concept strength metric (CSM) is described which can be used to determine how well the resulting decision tree can differentiate between the concepts it has learned. The CSM can be used to determine whether or not additional knowledge needs to be extracted from the database. An experiment involving real world data is presented to illustrate the concepts described.
Selection of examples in case-based computer-aided decision systems
Mazurowski, Maciej A.; Zurada, Jacek M.; Tourassi, Georgia D.
2013-01-01
Case-based computer-aided decision (CB-CAD) systems rely on a database of previously stored, known examples when classifying new, incoming queries. Such systems can be particularly useful since they do not need retraining every time a new example is deposited in the case base. The adaptive nature of case-based systems is well suited to the current trend of continuously expanding digital databases in the medical domain. To maintain efficiency, however, such systems need sophisticated strategies to effectively manage the available evidence database. In this paper, we discuss the general problem of building an evidence database by selecting the most useful examples to store while satisfying existing storage requirements. We evaluate three intelligent techniques for this purpose: genetic algorithm-based selection, greedy selection and random mutation hill climbing. These techniques are compared to a random selection strategy used as the baseline. The study is performed with a previously presented CB-CAD system applied for false positive reduction in screening mammograms. The experimental evaluation shows that when the development goal is to maximize the system’s diagnostic performance, the intelligent techniques are able to reduce the size of the evidence database to 37% of the original database by eliminating superfluous and/or detrimental examples while at the same time significantly improving the CAD system’s performance. Furthermore, if the case-base size is a main concern, the total number of examples stored in the system can be reduced to only 2–4% of the original database without a decrease in the diagnostic performance. Comparison of the techniques shows that random mutation hill climbing provides the best balance between the diagnostic performance and computational efficiency when building the evidence database of the CB-CAD system. PMID:18854606
Neumayr, Andreas; Tamarozzi, Francesca; Goblirsch, Sam; Blum, Johannes; Brunetti, Enrico
2013-01-01
Bone involvement in human cystic echinococcosis (CE) is rare, but affects the spine in approximately 50% of cases. Despite significant advances in diagnostic imaging techniques, surgical treatment and introduction of pharmacological therapy, spinal echinococcosis remains associated with a high degree of morbidity, disability and mortality. We systematically reviewed the published literature of the last five decades to update and summarize the currently existing data on treatment, follow-up and outcome of spinal CE. PMID:24069501
A new nanostructured Silicon biosensor for diagnostics of bovine leucosis
NASA Astrophysics Data System (ADS)
Luchenko, A. I.; Melnichenko, M. M.; Starodub, N. F.; Shmyryeva, O. M.
2010-08-01
In this report we propose a new instrumental method for the biochemical diagnostics of the bovine leucosis through the registration of the formation of the specific immune complex (antigen-antibody) with the help of biosensor based on the nano-structured silicon. The principle of the measurements is based on the determination of the photosensitivity of the surface. In spite of the existed traditional methods of the biochemical diagnostics of the bovine leucosis the proposed approach may provide the express control of the milk quality as direct on the farm and during the process raw materials. The proposed variant of the biosensor based on the nano-structured silicon may be applied for the determination of the concentration of different substances which may form the specific complex in the result of the bioaffine reactions. A new immune technique based on the nanostructured silicon and intended for the quantitative determination of some toxic substances is offered. The sensitivity of such biosensor allows determining T-2 mycotoxin at the concentration of 10 ng/ml during several minutes.
Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities
NASA Technical Reports Server (NTRS)
Grinstead, Jay H.; Wilder, Michael C.; Porter, Barry J.; Brown, Jeffrey D.; Yeung, Dickson; Battazzo, Stephen J.; Brubaker, Timothy R.
2016-01-01
The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (LIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper will document the latest improvements of the LIF system design and demonstrations of the redeveloped AHF and IHF LIF systems.
Plasma diagnostics for x-ray driven foils at Z
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heeter, R F; Bailey, J E; Cuneo, M E
We report the development of techniques to diagnose plasmas produced by X-ray photoionization of thin foils placed near the Z-pinch on the Sandia Z Machine. The development of 100+ TW X-ray sources enables access to novel plasma regimes, such as the photoionization equilibrium. To diagnose these plasmas one must simultaneously characterize both the foil and the driving pinch. The desired photoionized plasma equilibrium is only reached transiently for a 2-ns window, placing stringent requirements on diagnostic synchronization. We have adapted existing Sandia diagnostics and fielded an additional gated 3-crystal Johann spectrometer with dual lines of sight to meet these requirements.more » We present sample data from experiments in which 1 cm, 180 eV tungsten pinches photoionized foils composed of 200{angstrom} Fe and 300{angstrom} NaF co-mixed and sandwiched between 1000{angstrom} layers of Lexan (CHO), and discuss the application of this work to benchmarking astrophysical models.« less
Plasma diagnostics for x-ray driven foils at Z
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heeter, R. F.; Bailey, J. E.; Cuneo, M. E.
We report the development of techniques to diagnose plasmas produced by x-ray photoionization of thin foils placed near the Z-pinch on the Sandia Z Machine. The development of 100+ TW x-ray sources enables access to novel plasma regimes, such as the photoionization equilibrium. To diagnose these plasmas one must simultaneously characterize both the foil and the driving pinch. The desired photoionized plasma equilibrium is only reached transiently for a 2-ns window, placing stringent requirements on diagnostic synchronization. We have adapted existing Sandia diagnostics and fielded an additional gated three-crystal Johann spectrometer with dual lines of sight to meet these requirements.more » We present sample data from experiments using 1-cm, 180-eV tungsten pinches to photoionize foils made of 200 Aa Fe and 300 Aa NaF co-mixed and sandwiched between 1000 Aa layers of Lexan (C16H14O3), and discuss the application of this work to benchmarking astrophysical models.« less
Machine learning in heart failure: ready for prime time.
Awan, Saqib Ejaz; Sohel, Ferdous; Sanfilippo, Frank Mario; Bennamoun, Mohammed; Dwivedi, Girish
2018-03-01
The aim of this review is to present an up-to-date overview of the application of machine learning methods in heart failure including diagnosis, classification, readmissions and medication adherence. Recent studies have shown that the application of machine learning techniques may have the potential to improve heart failure outcomes and management, including cost savings by improving existing diagnostic and treatment support systems. Recently developed deep learning methods are expected to yield even better performance than traditional machine learning techniques in performing complex tasks by learning the intricate patterns hidden in big medical data. The review summarizes the recent developments in the application of machine and deep learning methods in heart failure management.
2000-02-01
HIDS] Program: Power Drive Train Crack Detection Diagnostics and Prognostics ife Usage Monitoring and Damage Tolerance; Techniques, Methodologies, and...and Prognostics , Life Usage Monitoring , and Damage Tolerance; Techniques, Methodologies, and Experiences Andrew Hess Harrison Chin William Hardman...continuing program and deployed engine monitoring systems in fixed to evaluate helicopter diagnostic, prognostic , and wing aircraft, notably on the A
Mohan, Suresh; Fuller, Jennifer C; Ford, Stephanie Friree; Lindsay, Robin W
2018-05-10
Nasal airway obstruction (NAO) is a common complaint in the otolaryngologist's office and can have a negative influence on quality of life (QOL). Existing diagnostic methods have improved, but little consensus exists on optimal tools. Furthermore, although surgical techniques for nasal obstruction continue to be developed, effective outcome measurement is lacking. An update of recent advances in diagnostic and therapeutic management of NAO is warranted. To review advances in diagnosis and treatment of NAO from the last 5 years. PubMed, Embase, CINAHL, the Cochrane Library, LILACS, Web of Science, and Guideline.gov were searched with the terms nasal obstruction and nasal blockage and their permutations from July 26, 2012, through October 23, 2017. Studies were included if they evaluated NAO using a subjective and an objective technique, and in the case of intervention-based studies, the Nasal Obstruction Symptom Evaluation (NOSE) scale and an objective technique. Exclusion criteria consisted of animal studies; patients younger than 14 years; nasal foreign bodies; nasal masses including polyps; choanal atresia; sinus disease; obstructive sleep apnea or sleep-disordered breathing; allergic rhinitis; and studies not specific to nasal obstruction. The initial search resulted in 942 articles. After independent screening by 2 investigators, 46 unique articles remained, including 2 randomized clinical trials, 3 systematic reviews, 3 meta-analyses, and 39 nonrandomized cohort studies (including a combined systematic review and meta-analysis). An aggregate of approximately 32 000 patients were reviewed (including meta-analyses). Of the subjective measures available for NAO, the NOSE scale is outstanding with regard to disease-specific validation and correlation with symptoms. No currently available objective measure can be considered a criterion standard. Structural measures of flow, pressure, and volume appear to be necessary but insufficient to assess NAO. Therefore, novel variables and techniques must continue to be explored in search of an ideal instrument to aid in assessment of surgical outcomes. Nasal airway obstruction is a clinical diagnosis with considerable effects on QOL. An adequate diagnosis begins with a focused history and physical examination and requires a patient QOL measure such as the NOSE scale. Objective measures should be adjunctive and require further validation for widespread adoption. These results are limited by minimal high-quality evidence among studies and the risk of bias in observational studies. NA.
An automated computerized auscultation and diagnostic system for pulmonary diseases.
Abbas, Ali; Fahim, Atef
2010-12-01
Respiratory sounds are of significance as they provide valuable information on the health of the respiratory system. Sounds emanating from the respiratory system are uneven, and vary significantly from one individual to another and for the same individual over time. In and of themselves they are not a direct proof of an ailment, but rather an inference that one exists. Auscultation diagnosis is an art/skill that is acquired and honed by practice; hence it is common to seek confirmation using invasive and potentially harmful imaging diagnosis techniques like X-rays. This research focuses on developing an automated auscultation diagnostic system that overcomes the limitations inherent in traditional auscultation techniques. The system uses a front end sound signal filtering module that uses adaptive Neural Networks (NN) noise cancellation to eliminate spurious sound signals like those from the heart, intestine, and ambient noise. To date, the core diagnosis module is capable of identifying lung sounds from non-lung sounds, normal lung sounds from abnormal ones, and identifying wheezes from crackles as indicators of different ailments.
DNA-mounted self-assembly: new approaches for genomic analysis and SNP detection.
Bichenkova, Elena V; Lang, Zhaolei; Yu, Xuan; Rogert, Candelaria; Douglas, Kenneth T
2011-01-01
This article presents an overview of new emerging approaches for nucleic acid detection via hybridization techniques that can potentially be applied to genomic analysis and SNP identification in clinical diagnostics. Despite the availability of a diverse variety of SNP genotyping technologies on the diagnostic market, none has truly succeeded in dominating its competitors thus far. Having been designed for specific diagnostic purposes or clinical applications, each of the existing bio-assay systems (briefly outlined here) is usually limited to a relatively narrow aspect or format of nucleic acid detection, and thus cannot entirely satisfy all the varieties of commercial requirements and clinical demands. This drives the diagnostic sector to pursue novel, cost-effective approaches to ensure rapid and reliable identification of pathogenic or hereditary human diseases. Hence, the purpose of this review is to highlight some new strategic directions in DNA detection technologies in order to inspire development of novel molecular diagnostic tools and bio-assay systems with superior reliability, reproducibility, robustness, accuracy and sensitivity at lower assay cost. One approach to improving the sensitivity of an assay to confidently discriminate between single point mutations is based on the use of target assembled, split-probe systems, which constitutes the main focus of this review. Copyright © 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Castellini, Paolo; Esposito, Enrico; Marchetti, Barbara; Paone, Nicola; Tomasini, Enrico P.
2001-10-01
During the last years the growing importance of the correct determination of the state of conservation of artworks has been stated by all personalities in care of Cultural Heritage. There exist many analytical methodologies and techniques to individuate the physical and chemical characteristics of artworks, but at present their structural diagnostics mainly rely on the expertise of the restorer and the typical diagnostic process is accomplished mainly through manual and visual inspection of the object surface. The basic idea behind the proposed technique is to substitute human senses with measurement instruments: surfaces are very slightly vibrated by mechanical actuators, while a laser Doppler vibrometer scans the objects measuring surface velocity and producing 2D or 3D maps. Where a defect occurs velocity is higher than neighboring areas so defects can be easily spotted. Laser vibrometers also identify structural resonance frequencies thus leading to a complete characterization of defects. This work will present the most recent results coming out of the application of Scanning Laser Doppler Vibrometers (SLDV) to different types of artworks: mosaics, ceramics, inlaid wood and easel painting. Real artworks and samples realized on purpose have been studied using the proposed technique and different measuring issues resulting from each artwork category will be described.
Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David; Šlapeta, Jan
2017-09-01
Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74-0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic to non-endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65-88%), compared to the sensitivity (91-100%) of the new molecular diagnostic workflow. Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited.
Intelligent model-based diagnostics for vehicle health management
NASA Astrophysics Data System (ADS)
Luo, Jianhui; Tu, Fang; Azam, Mohammad S.; Pattipati, Krishna R.; Willett, Peter K.; Qiao, Liu; Kawamoto, Masayuki
2003-08-01
The recent advances in sensor technology, remote communication and computational capabilities, and standardized hardware/software interfaces are creating a dramatic shift in the way the health of vehicles is monitored and managed. These advances facilitate remote monitoring, diagnosis and condition-based maintenance of automotive systems. With the increased sophistication of electronic control systems in vehicles, there is a concomitant increased difficulty in the identification of the malfunction phenomena. Consequently, the current rule-based diagnostic systems are difficult to develop, validate and maintain. New intelligent model-based diagnostic methodologies that exploit the advances in sensor, telecommunications, computing and software technologies are needed. In this paper, we will investigate hybrid model-based techniques that seamlessly employ quantitative (analytical) models and graph-based dependency models for intelligent diagnosis. Automotive engineers have found quantitative simulation (e.g. MATLAB/SIMULINK) to be a vital tool in the development of advanced control systems. The hybrid method exploits this capability to improve the diagnostic system's accuracy and consistency, utilizes existing validated knowledge on rule-based methods, enables remote diagnosis, and responds to the challenges of increased system complexity. The solution is generic and has the potential for application in a wide range of systems.
Hardware implementation of hierarchical volume subdivision-based elastic registration.
Dandekar, Omkar; Walimbe, Vivek; Shekhar, Raj
2006-01-01
Real-time, elastic and fully automated 3D image registration is critical to the efficiency and effectiveness of many image-guided diagnostic and treatment procedures relying on multimodality image fusion or serial image comparison. True, real-time performance will make many 3D image registration-based techniques clinically viable. Hierarchical volume subdivision-based image registration techniques are inherently faster than most elastic registration techniques, e.g. free-form deformation (FFD)-based techniques, and are more amenable for achieving real-time performance through hardware acceleration. Our group has previously reported an FPGA-based architecture for accelerating FFD-based image registration. In this article we show how our existing architecture can be adapted to support hierarchical volume subdivision-based image registration. A proof-of-concept implementation of the architecture achieved speedups of 100 for elastic registration against an optimized software implementation on a 3.2 GHz Pentium III Xeon workstation. Due to inherent parallel nature of the hierarchical volume subdivision-based image registration techniques further speedup can be achieved by using several computing modules in parallel.
Boonsarngsuk, Viboon; Kanoksil, Wasana; Laungdamerongchai, Sarangrat
2015-04-01
There are many sampling techniques dedicated to radial endobronchial ultrasound (R-EBUS) guided flexible bronchoscopy (FB). However, data regarding the diagnostic performances among bronchoscopic sampling techniques is limited. This study was conducted to compare the diagnostic yields among bronchoscopic sampling techniques in the diagnosis of peripheral pulmonary lesions (PPLs). A prospective study was conducted on 112 patients who were diagnosed with PPLs and underwent R-EBUS-guided FB between Oct 2012 and Sep 2014. Sampling techniques-including transbronchial biopsy (TBB), brushing cell block, brushing smear, rinsed fluid of brushing, and bronchoalveolar lavage (BAL)-were evaluated for the diagnosis. The mean diameter of the PPLs was 23.5±9.5 mm. The final diagnoses included 76 malignancies and 36 benign lesions. The overall diagnostic yield of R-EBUS-guided bronchoscopy was 80.4%; TBB gave the highest yield among the 112 specimens: 70.5%, 34.8%, 62.5%, 50.0% and 42.0% for TBB, brushing cell block, brushing smear, rinsed brushing fluid, and BAL fluid (BALF), respectively (P<0.001). TBB provided high diagnostic yield irrespective of the size and etiology of the PPLs. The combination of TBB and brushing smear achieved the maximum diagnostic yield. Of 31 infectious PPLs, BALF culture gave additional microbiological information in 20 cases. TBB provided the highest diagnostic yield; however, to achieve the highest diagnostic performance, TBB, brushing smear and BAL techniques should be performed together.
Region of interest processing for iterative reconstruction in x-ray computed tomography
NASA Astrophysics Data System (ADS)
Kopp, Felix K.; Nasirudin, Radin A.; Mei, Kai; Fehringer, Andreas; Pfeiffer, Franz; Rummeny, Ernst J.; Noël, Peter B.
2015-03-01
The recent advancements in the graphics card technology raised the performance of parallel computing and contributed to the introduction of iterative reconstruction methods for x-ray computed tomography in clinical CT scanners. Iterative maximum likelihood (ML) based reconstruction methods are known to reduce image noise and to improve the diagnostic quality of low-dose CT. However, iterative reconstruction of a region of interest (ROI), especially ML based, is challenging. But for some clinical procedures, like cardiac CT, only a ROI is needed for diagnostics. A high-resolution reconstruction of the full field of view (FOV) consumes unnecessary computation effort that results in a slower reconstruction than clinically acceptable. In this work, we present an extension and evaluation of an existing ROI processing algorithm. Especially improvements for the equalization between regions inside and outside of a ROI are proposed. The evaluation was done on data collected from a clinical CT scanner. The performance of the different algorithms is qualitatively and quantitatively assessed. Our solution to the ROI problem provides an increase in signal-to-noise ratio and leads to visually less noise in the final reconstruction. The reconstruction speed of our technique was observed to be comparable with other previous proposed techniques. The development of ROI processing algorithms in combination with iterative reconstruction will provide higher diagnostic quality in the near future.
Advantages and disadvantages of technologies for HER2 testing in breast cancer specimens.
Furrer, Daniela; Sanschagrin, François; Jacob, Simon; Diorio, Caroline
2015-11-01
Human epidermal growth factor receptor 2 (HER2) plays a central role as a prognostic and predictive marker in breast cancer specimens. Reliable HER2 evaluation is central to determine the eligibility of patients with breast cancer to targeted anti-HER2 therapies such as trastuzumab and lapatinib. Presently, several methods exist for the determination of HER2 status at different levels (protein, RNA, and DNA level). In this review, we discuss the main advantages and disadvantages of the techniques developed so far for the evaluation of HER2 status in breast cancer specimens. Each technique has its own advantages and disadvantages. It is therefore not surprising that no consensus has been reached so far on which technique is the best for the determination of HER2 status. Currently, emphasis must be put on standardization of procedures, internal and external quality control assessment, and competency evaluation of already existing methods to ensure accurate, reliable, and clinically meaningful test results. Development of new robust and accurate diagnostic assays should also be encouraged. In addition, large clinical trials are warranted to identify the technique that most reliably predicts a positive response to anti-HER2 drugs. Copyright© by the American Society for Clinical Pathology.
Emerging applications of nanoparticles: Biomedical and environmental
NASA Astrophysics Data System (ADS)
Gulati, Shivani; Sachdeva, M.; Bhasin, K. K.
2018-05-01
Nanotechnology finds a wide range of applications from energy production to industrial fabrication processes to biomedical applications. Nanoparticles (NPs) can be engineered to possess unique compositions and functionalities to empower novel tools and techniques that have not existed previously in biomedical research. The unique size and shape dependent physicochemical properties along with their unique spectral and optical properties have prompted the development of a wide variety of potential applications in the field of diagnostics and medicines. In the plethora of scientific and technological fields, environmental safety is also a big concern. For this purpose, nanomaterials have been functionalized to cope up the existing pollution, improving manufacturing methods to reduce the generation of new pollution, and making alternative and more cost effective energy sources.
75 FR 35439 - Medical Diagnostic Equipment Accessibility Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-22
... ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD Medical Diagnostic Equipment... accessibility standards for medical diagnostic equipment to ensure that such equipment is accessible to, and... respect to medical diagnostic equipment and existing guidance for designing accessible medical diagnostic...
NASA Astrophysics Data System (ADS)
Krotov, Aleksei; Pankin, Victor
2017-09-01
The assessment of central circulation (including heart function) parameters is vital in the preventive diagnostics of inherent and acquired heart failures and during polychemotherapy. The protocols currently applied in Russia do not fully utilize the first-pass assessment (FPRNA) and that results in poor data formalization, while the FPRNA is the one of the fastest, affordable and compact methods among other radioisotope diagnostics protocols. A non-imaging algorithm basing on existing protocols has been designed to use the readings of an additional detector above vena subclavia to determine the total blood volume (TBV), not requiring blood sampling in contrast to current protocols. An automated processing of precordial detector readings is presented, in order to determine the heart strike volume (SV). Two techniques to estimate the ejection fraction (EF) of the heart are discussed.
Biomagnetism using SQUIDs: status and perspectives
NASA Astrophysics Data System (ADS)
Sternickel, Karsten; Braginski, Alex I.
2006-03-01
Biomagnetism involves the measurement and analysis of very weak local magnetic fields of living organisms and various organs in humans. Such fields can be of physiological origin or due to magnetic impurities or markers. This paper reviews existing and prospective applications of biomagnetism in clinical research and medical diagnostics. Currently, such applications require sensitive magnetic SQUID sensors and amplifiers. The practicality of biomagnetic methods depends especially on techniques for suppressing the dominant environmental electromagnetic noise, and on suitable nearly real-time data processing and interpretation methods. Of the many biomagnetic methods and applications, only the functional studies of the human brain (magnetoencephalography) and liver susceptometry are in clinical use, while functional diagnostics of the human heart (magnetocardiography) approaches the threshold of clinical acceptance. Particularly promising for the future is the ongoing research into low-field magnetic resonance anatomical imaging using SQUIDs.
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, Mohamed
2012-01-01
Photoplethysmography (PPG) is used to estimate the skin blood flow using infrared light. Researchers from different domains of science have become increasingly interested in PPG because of its advantages as non-invasive, inexpensive, and convenient diagnostic tool. Traditionally, it measures the oxygen saturation, blood pressure, cardiac output, and for assessing autonomic functions. Moreover, PPG is a promising technique for early screening of various atherosclerotic pathologies and could be helpful for regular GP-assessment but a full understanding of the diagnostic value of the different features is still lacking. Recent studies emphasise the potential information embedded in the PPG waveform signal and it deserves further attention for its possible applications beyond pulse oximetry and heart-rate calculation. Therefore, this overview discusses different types of artifact added to PPG signal, characteristic features of PPG waveform, and existing indexes to evaluate for diagnoses. PMID:22845812
Integrated Artificial Intelligence Approaches for Disease Diagnostics.
Vashistha, Rajat; Chhabra, Deepak; Shukla, Pratyoosh
2018-06-01
Mechanocomputational techniques in conjunction with artificial intelligence (AI) are revolutionizing the interpretations of the crucial information from the medical data and converting it into optimized and organized information for diagnostics. It is possible due to valuable perfection in artificial intelligence, computer aided diagnostics, virtual assistant, robotic surgery, augmented reality and genome editing (based on AI) technologies. Such techniques are serving as the products for diagnosing emerging microbial or non microbial diseases. This article represents a combinatory approach of using such approaches and providing therapeutic solutions towards utilizing these techniques in disease diagnostics.
Chi, Chongwei; Du, Yang; Ye, Jinzuo; Kou, Deqiang; Qiu, Jingdan; Wang, Jiandong; Tian, Jie; Chen, Xiaoyuan
2014-01-01
Cancer is a major threat to human health. Diagnosis and treatment using precision medicine is expected to be an effective method for preventing the initiation and progression of cancer. Although anatomical and functional imaging techniques such as radiography, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) have played an important role for accurate preoperative diagnostics, for the most part these techniques cannot be applied intraoperatively. Optical molecular imaging is a promising technique that provides a high degree of sensitivity and specificity in tumor margin detection. Furthermore, existing clinical applications have proven that optical molecular imaging is a powerful intraoperative tool for guiding surgeons performing precision procedures, thus enabling radical resection and improved survival rates. However, detection depth limitation exists in optical molecular imaging methods and further breakthroughs from optical to multi-modality intraoperative imaging methods are needed to develop more extensive and comprehensive intraoperative applications. Here, we review the current intraoperative optical molecular imaging technologies, focusing on contrast agents and surgical navigation systems, and then discuss the future prospects of multi-modality imaging technology for intraoperative imaging-guided cancer surgery.
Chi, Chongwei; Du, Yang; Ye, Jinzuo; Kou, Deqiang; Qiu, Jingdan; Wang, Jiandong; Tian, Jie; Chen, Xiaoyuan
2014-01-01
Cancer is a major threat to human health. Diagnosis and treatment using precision medicine is expected to be an effective method for preventing the initiation and progression of cancer. Although anatomical and functional imaging techniques such as radiography, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) have played an important role for accurate preoperative diagnostics, for the most part these techniques cannot be applied intraoperatively. Optical molecular imaging is a promising technique that provides a high degree of sensitivity and specificity in tumor margin detection. Furthermore, existing clinical applications have proven that optical molecular imaging is a powerful intraoperative tool for guiding surgeons performing precision procedures, thus enabling radical resection and improved survival rates. However, detection depth limitation exists in optical molecular imaging methods and further breakthroughs from optical to multi-modality intraoperative imaging methods are needed to develop more extensive and comprehensive intraoperative applications. Here, we review the current intraoperative optical molecular imaging technologies, focusing on contrast agents and surgical navigation systems, and then discuss the future prospects of multi-modality imaging technology for intraoperative imaging-guided cancer surgery. PMID:25250092
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boucher, Laurel
In an era of budget cuts and declining resources, an increased need exists for government agencies to develop formal and informal partnerships. Such partnerships are a means through which government agencies can use their resources to accomplish together what they cannot accomplish on their own. Interagency partnerships may involve multiple government agencies, private contractors, national laboratories, technology developers, public representatives, and other stakeholders. Four elements of strong and healthy interagency partnerships are presented as well as three needs that must be satisfied for the partnership to last. A diagnostic tool to measure the strength of these building blocks within anmore » existing partnership is provided. Tools, techniques, and templates to develop these fundamental elements within a new partnership or to strengthen those within an already existing partnership are presented. This includes a comprehensive template for a partnership agreement along with practical suggestions as membership, operations, and decisions-making. (authors)« less
Neumayr, Andreas; Tamarozzi, Francesca; Goblirsch, Sam; Blum, Johannes; Brunetti, Enrico
2013-01-01
Bone involvement in human cystic echinococcosis (CE) is rare, but affects the spine in approximately 50% of cases. Despite significant advances in diagnostic imaging techniques as well as surgical and medical treatment of spinal CE, our basic understanding of the parasite's predilection for the spine remains incomplete. To fill this gap, we systematically reviewed the published literature of the last five decades to summarize and analyze the currently existing data on epidemiological and anatomical aspects of spinal CE. PMID:24086783
Helmer, R; Koschorek, F; Terwey, B; Frauen, T
1986-01-01
Nuclear spin tomography since its beginnings in the seventies has steadily gained in importance as a method of examination in medical diagnostics as it produces a picture. In the field of forensic medicine the NMR technique as used for anatomic-anthropologic issues attempting to identify skulls this is a valuable supplement to an extension of the existing methods of investigation. The results of a measurement of the thickness of soft facial tissue in a live test person is shown as compared to measures obtained by sonography.
A comparative study of electrical probe techniques for plasma diagnostics
NASA Technical Reports Server (NTRS)
Szuszczewicz, E. P.
1972-01-01
Techniques for using electrical probes for plasma diagnostics are reviewed. Specific consideration is given to the simple Langmuir probe, the symmetric double probe of Johnson and Malter, the variable-area probe of Fetz and Oeschsner, and a floating probe technique. The advantages and disadvantages of each technique are discussed.
Exploring the Case for a Global Alliance for Medical Diagnostics Initiative
Mugambi, Melissa L.; Palamountain, Kara M.; Gallarda, Jim; Drain, Paul K.
2017-01-01
In recent years, the private and public sectors have increased investments in medical diagnostics for low- and middle-income countries (LMICs). Despite these investments, numerous barriers prevent the adoption of existing diagnostics and discourage the development and introduction of new diagnostics in LMICs. In the late 1990s, the global vaccine community had similar challenges, as vaccine coverage rates stagnated and the introduction of new vaccines was viewed as a distraction to delivering existing vaccines. To address these challenges, the international community came together and formed the Global Alliance for Vaccines Initiative (GAVI). Sixteen years after the formation of GAVI, we see evidence of a healthier global vaccine landscape. We discuss how GAVI’s four guiding principles (product, health systems strengthening, financing and market shaping) might apply to the advancement of medical diagnostics in LMICs. We present arguments for the international community and existing organizations to establish a Global Alliance for Medical Diagnostics Initiative (GAMDI). PMID:28134750
Teledermatology. Current status and future directions.
Whited, J D
2001-01-01
Teledermatology is becoming an increasingly common means of delivering dermatologic healthcare worldwide and will almost certainly play a greater role in the future. The type of technology used distinguishes the 2 modes of teledermatology consultation. The store and forward technique uses still digital images generated by a digital camera. Consultations of this type are considered asynchronous since the images are obtained, sent, and reviewed at different times. In contrast, real-time interactive consultations are synchronous. Patients and clinicians interact in real-time through an audio-video communication link. Each modality has its advantages and disadvantages, and studies appear in the literature that assess both technologies. Although diagnostic reliability (precision) assessments for teledermatology are subject to limitations, existing information indicates that both store and forward and real-time interactive technology result in reliable diagnostic outcomes when compared with clinic-based evaluations. Less information regarding diagnostic accuracy is available; however, one evaluation that used store and forward technology found comparable diagnostic accuracy between teledermatology consultations and clinic-based examinations. Currently, little information is available regarding cost effectiveness and patient outcomes. Existing evidence, while inconclusive, suggests that teledermatology may be more costly than traditional clinic-based care, especially when using real-time interactive technology. Teledermatology has been shown to have utility as a triage mechanism for determining the urgency or need for a clinic-based consultation. Overall, patients appear to accept teledermatology and are satisfied with it as a means of obtaining healthcare. Clinicians have also generally reported positive experiences with teledermatology. Future studies that focus on cost effectiveness, patient outcomes, and patient and clinician satisfaction will help further define the potential of teledermatology as a means of dermatologic healthcare delivery.
NASA Astrophysics Data System (ADS)
Zhang, Ji; Ding, Mingyue; Yuchi, Ming; Hou, Wenguang; Ye, Huashan; Qiu, Wu
2010-03-01
Factor analysis is an efficient technique to the analysis of dynamic structures in medical image sequences and recently has been used in contrast-enhanced ultrasound (CEUS) of hepatic perfusion. Time-intensity curves (TICs) extracted by factor analysis can provide much more diagnostic information for radiologists and improve the diagnostic rate of focal liver lesions (FLLs). However, one of the major drawbacks of factor analysis of dynamic structures (FADS) is nonuniqueness of the result when only the non-negativity criterion is used. In this paper, we propose a new method of replace-approximation based on apex-seeking for ambiguous FADS solutions. Due to a partial overlap of different structures, factor curves are assumed to be approximately replaced by the curves existing in medical image sequences. Therefore, how to find optimal curves is the key point of the technique. No matter how many structures are assumed, our method always starts to seek apexes from one-dimensional space where the original high-dimensional data is mapped. By finding two stable apexes from one dimensional space, the method can ascertain the third one. The process can be continued until all structures are found. This technique were tested on two phantoms of blood perfusion and compared to the two variants of apex-seeking method. The results showed that the technique outperformed two variants in comparison of region of interest measurements from phantom data. It can be applied to the estimation of TICs derived from CEUS images and separation of different physiological regions in hepatic perfusion.
Measurements and Diagnostics of Diamond Films and Coatings
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Wu, Richard L. C.
1999-01-01
The commercial potential of chemical-vapor-deposited (CVD) diamond films has been established and a number of applications have been identified through university, industry, and government research studies. This paper discusses the methodologies used for property measurement and diagnostic of CVD diamond films and coatings. Measurement and diagnostic techniques studied include scanning electron microscopy, transmission electron microscopy, atomic force microscopy, stylus profilometry, x-ray diffraction, electron diffraction, Raman spectroscopy, Rutherford backscattering, elastic recoil spectroscopy, and friction examination. Each measurement and diagnostic technique provides unique information. A combination of techniques can provide the technical information required to understand the quality and properties of CVD diamond films, which are important to their application in specific component systems and environments. In this study the combination of measurement and diagnostic techniques was successfully applied to correlate deposition parameters and resultant diamond film composition, crystallinity, grain size, surface roughness, and coefficient of friction.
Feature diagnosticity and task context shape activity in human scene-selective cortex.
Lowe, Matthew X; Gallivan, Jason P; Ferber, Susanne; Cant, Jonathan S
2016-01-15
Scenes are constructed from multiple visual features, yet previous research investigating scene processing has often focused on the contributions of single features in isolation. In the real world, features rarely exist independently of one another and likely converge to inform scene identity in unique ways. Here, we utilize fMRI and pattern classification techniques to examine the interactions between task context (i.e., attend to diagnostic global scene features; texture or layout) and high-level scene attributes (content and spatial boundary) to test the novel hypothesis that scene-selective cortex represents multiple visual features, the importance of which varies according to their diagnostic relevance across scene categories and task demands. Our results show for the first time that scene representations are driven by interactions between multiple visual features and high-level scene attributes. Specifically, univariate analysis of scene-selective cortex revealed that task context and feature diagnosticity shape activity differentially across scene categories. Examination using multivariate decoding methods revealed results consistent with univariate findings, but also evidence for an interaction between high-level scene attributes and diagnostic visual features within scene categories. Critically, these findings suggest visual feature representations are not distributed uniformly across scene categories but are shaped by task context and feature diagnosticity. Thus, we propose that scene-selective cortex constructs a flexible representation of the environment by integrating multiple diagnostically relevant visual features, the nature of which varies according to the particular scene being perceived and the goals of the observer. Copyright © 2015 Elsevier Inc. All rights reserved.
20 CFR 404.1579 - How we will determine whether your disability continues or ends.
Code of Federal Regulations, 2012 CFR
2012-04-01
... application. (2) Substantial evidence shows that based on new or improved diagnostic or evaluative techniques... favorable decision. Changing methodologies and advances in medical and other diagnostic or evaluative... subpart will be based on new or improved diagnostic or evaluative techniques. Such listing changes will...
20 CFR 404.1579 - How we will determine whether your disability continues or ends.
Code of Federal Regulations, 2014 CFR
2014-04-01
... application. (2) Substantial evidence shows that based on new or improved diagnostic or evaluative techniques... favorable decision. Changing methodologies and advances in medical and other diagnostic or evaluative... subpart will be based on new or improved diagnostic or evaluative techniques. Such listing changes will...
20 CFR 404.1579 - How we will determine whether your disability continues or ends.
Code of Federal Regulations, 2010 CFR
2010-04-01
... application. (2) Substantial evidence shows that based on new or improved diagnostic or evaluative techniques... favorable decision. Changing methodologies and advances in medical and other diagnostic or evaluative... subpart will be based on new or improved diagnostic or evaluative techniques. Such listing changes will...
20 CFR 404.1579 - How we will determine whether your disability continues or ends.
Code of Federal Regulations, 2011 CFR
2011-04-01
... application. (2) Substantial evidence shows that based on new or improved diagnostic or evaluative techniques... favorable decision. Changing methodologies and advances in medical and other diagnostic or evaluative... subpart will be based on new or improved diagnostic or evaluative techniques. Such listing changes will...
20 CFR 404.1579 - How we will determine whether your disability continues or ends.
Code of Federal Regulations, 2013 CFR
2013-04-01
... application. (2) Substantial evidence shows that based on new or improved diagnostic or evaluative techniques... favorable decision. Changing methodologies and advances in medical and other diagnostic or evaluative... subpart will be based on new or improved diagnostic or evaluative techniques. Such listing changes will...
Advances in paper-based sample pretreatment for point-of-care testing.
Tang, Rui Hua; Yang, Hui; Choi, Jane Ru; Gong, Yan; Feng, Shang Sheng; Pingguan-Murphy, Belinda; Huang, Qing Sheng; Shi, Jun Ling; Mei, Qi Bing; Xu, Feng
2017-06-01
In recent years, paper-based point-of-care testing (POCT) has been widely used in medical diagnostics, food safety and environmental monitoring. However, a high-cost, time-consuming and equipment-dependent sample pretreatment technique is generally required for raw sample processing, which are impractical for low-resource and disease-endemic areas. Therefore, there is an escalating demand for a cost-effective, simple and portable pretreatment technique, to be coupled with the commonly used paper-based assay (e.g. lateral flow assay) in POCT. In this review, we focus on the importance of using paper as a platform for sample pretreatment. We firstly discuss the beneficial use of paper for sample pretreatment, including sample collection and storage, separation, extraction, and concentration. We highlight the working principle and fabrication of each sample pretreatment device, the existing challenges and the future perspectives for developing paper-based sample pretreatment technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duncan, L.M.
1995-12-12
The objectives of this research and development program were to conduct simulation modeling of the generation and propagation of atmospheric acoustic signals associated with surface and subsurface ground disturbances; to construct an experimental measurement system for exploratory research studies of acoustic generated ionospheric disturbances; to model high power radio wave propagation through the ionosphere, including nonlinear wave plasma interaction effects; and to assist in the assessment of diagnostic systems for observation of ionospheric modification experiments using existing and planned high latitude high power RF transmitting facilities. A computer simulation of ionospheric response to ground launched acoustic pulses was constructed andmore » results compared to observational data associated with HF and incoherent scatter radar measurements of ionospheric effects produced by earthquakes and ground level explosions. These results were then utilized to help define the design, construct and test for an HF Doppler radar system. In addition, an assessment was conducted of ionospheric diagnostic instruments proposed for the Air Force/Navy High Frequency Active Auroral Research Program (HAARP).« less
NASA Astrophysics Data System (ADS)
Reimer, R.; Marchuk, O.; Geiger, B.; Mc Carthy, P. J.; Dunne, M.; Hobirk, J.; Wolf, R.; ASDEX Upgrade Team
2017-08-01
The Motional Stark Effect (MSE) diagnostic is a well established technique to infer the local internal magnetic field in fusion plasmas. In this paper, the existing forward model which describes the MSE data is extended by the Zeeman effect, fine-structure, and relativistic corrections in the interpretation of the MSE spectra for different experimental conditions at the tokamak ASDEX Upgrade. The contribution of the non-Local Thermodynamic Equilibrium (non-LTE) populations among the magnetic sub-levels and the Zeeman effect on the derived plasma parameters is different. The obtained pitch angle is changed by 3 ° … 4 ° and by 0 . 5 ° … 1 ° including the non-LTE and the Zeeman effects into the standard statistical MSE model. The total correction is about 4°. Moreover, the variation of the magnetic field strength is significantly changed by 2.2% due to the Zeeman effect only. While the data on the derived pitch angle still could not be tested against the other diagnostics, the results from an equilibrium reconstruction solver confirm the obtained values for magnetic field strength.
Ye, Qing; Pan, Hao; Liu, Changhua
2015-01-01
This research proposes a novel framework of final drive simultaneous failure diagnosis containing feature extraction, training paired diagnostic models, generating decision threshold, and recognizing simultaneous failure modes. In feature extraction module, adopt wavelet package transform and fuzzy entropy to reduce noise interference and extract representative features of failure mode. Use single failure sample to construct probability classifiers based on paired sparse Bayesian extreme learning machine which is trained only by single failure modes and have high generalization and sparsity of sparse Bayesian learning approach. To generate optimal decision threshold which can convert probability output obtained from classifiers into final simultaneous failure modes, this research proposes using samples containing both single and simultaneous failure modes and Grid search method which is superior to traditional techniques in global optimization. Compared with other frequently used diagnostic approaches based on support vector machine and probability neural networks, experiment results based on F 1-measure value verify that the diagnostic accuracy and efficiency of the proposed framework which are crucial for simultaneous failure diagnosis are superior to the existing approach. PMID:25722717
Emerging applications of fluorescence spectroscopy in medical microbiology field.
Shahzad, Aamir; Köhler, Gottfried; Knapp, Martin; Gaubitzer, Erwin; Puchinger, Martin; Edetsberger, Michael
2009-11-26
There are many diagnostic techniques and methods available for diagnosis of medically important microorganisms like bacteria, viruses, fungi and parasites. But, almost all these techniques and methods have some limitations or inconvenience. Most of these techniques are laborious, time consuming and with chances of false positive or false negative results. It warrants the need of a diagnostic technique which can overcome these limitations and problems. At present, there is emerging trend to use Fluorescence spectroscopy as a diagnostic as well as research tool in many fields of medical sciences. Here, we will critically discuss research studies which propose that Fluorescence spectroscopy may be an excellent diagnostic as well as excellent research tool in medical microbiology field with high sensitivity and specificity.
Dahlberg, Jerry; Tkacik, Peter T; Mullany, Brigid; Fleischhauer, Eric; Shahinian, Hossein; Azimi, Farzad; Navare, Jayesh; Owen, Spencer; Bisel, Tucker; Martin, Tony; Sholar, Jodie; Keanini, Russell G
2017-12-04
An analog, macroscopic method for studying molecular-scale hydrodynamic processes in dense gases and liquids is described. The technique applies a standard fluid dynamic diagnostic, particle image velocimetry (PIV), to measure: i) velocities of individual particles (grains), extant on short, grain-collision time-scales, ii) velocities of systems of particles, on both short collision-time- and long, continuum-flow-time-scales, iii) collective hydrodynamic modes known to exist in dense molecular fluids, and iv) short- and long-time-scale velocity autocorrelation functions, central to understanding particle-scale dynamics in strongly interacting, dense fluid systems. The basic system is composed of an imaging system, light source, vibrational sensors, vibrational system with a known media, and PIV and analysis software. Required experimental measurements and an outline of the theoretical tools needed when using the analog technique to study molecular-scale hydrodynamic processes are highlighted. The proposed technique provides a relatively straightforward alternative to photonic and neutron beam scattering methods traditionally used in molecular hydrodynamic studies.
Volumetric velocimetry for fluid flows
NASA Astrophysics Data System (ADS)
Discetti, Stefano; Coletti, Filippo
2018-04-01
In recent years, several techniques have been introduced that are capable of extracting 3D three-component velocity fields in fluid flows. Fast-paced developments in both hardware and processing algorithms have generated a diverse set of methods, with a growing range of applications in flow diagnostics. This has been further enriched by the increasingly marked trend of hybridization, in which the differences between techniques are fading. In this review, we carry out a survey of the prominent methods, including optical techniques and approaches based on medical imaging. An overview of each is given with an example of an application from the literature, while focusing on their respective strengths and challenges. A framework for the evaluation of velocimetry performance in terms of dynamic spatial range is discussed, along with technological trends and emerging strategies to exploit 3D data. While critical challenges still exist, these observations highlight how volumetric techniques are transforming experimental fluid mechanics, and that the possibilities they offer have just begun to be explored.
The implementation of liquid-based cytology for lung and pleural-based diseases.
Michael, Claire W; Bedrossian, Carlos C W M
2014-01-01
First introduced for the processing of cervico-vaginal samples, liquid-based cytology (LBC) soon found application in nongynecological specimens, including bronchoscopic brushings, washings and transcutaneous and transbronchial aspiration biopsy of the lung as well as pleural effusions. This article reviews the existing literature related to these specimens along with the authors' own experience. A literature review was conducted through Ovid MEDLINE and PubMed search engines using several key words. Most of the literature is based on data collected through the use of split samples. The data confirms that the use of LBC is an acceptable, and sometimes superior, alternative to the conventional preparations (CP). LBC offers several advantages, including the ability to transport in a stable collecting media, elimination of obscuring elements, ease of screening, excellent preservation, random representative sample, and application of ancillary techniques on additional preparations. Some diagnostic pitfalls related to the introduced artifacts were reported. The utilization of LBC offers many advantages over CP and has a diagnostic accuracy that is equal to or surpasses that of CP. LBC affords a bridge to the future application of molecular and other ancillary techniques to cytology. Knowledge of the morphological artifacts is useful at the early stages of implementation.
3D Printing and Assay Development for Point-of-Care Applications
NASA Astrophysics Data System (ADS)
Jagadeesh, Shreesha
Existing centralized labs do not serve patients adequately in remote areas. To enable universal timely healthcare, there is a need to develop low cost, portable systems that can diagnose multiple disease (Point-of-Care (POC) devices). Future POC diagnostics can be more multi-functional if medical device vendors can develop interoperability standards. This thesis developed the following medical diagnostic modules: Plasma from 25 microl blood was extracted through a filter membrane to demonstrate a 3D printed sample preparation module. Sepsis biomarker, C - reactive protein, was quantified through adsorption on nylon beads to demonstrate bead-based assay suitable for 3D printed disposable cartridge module. Finally, a modular fluorescent detection kit was built using 3D printed parts to detect CD4 cells in a disposable cartridge from ChipCare Corp. Due to the modularity enabled by 3D printing technique, the developed units can be easily adapted to detect other diseases.
Kucukkal, Tugba G.; Yang, Ye; Chapman, Susan C.; Cao, Weiguo; Alexov, Emil
2014-01-01
DNA mutations are the cause of many human diseases and they are the reason for natural differences among individuals by affecting the structure, function, interactions, and other properties of DNA and expressed proteins. The ability to predict whether a given mutation is disease-causing or harmless is of great importance for the early detection of patients with a high risk of developing a particular disease and would pave the way for personalized medicine and diagnostics. Here we review existing methods and techniques to study and predict the effects of DNA mutations from three different perspectives: in silico, in vitro and in vivo. It is emphasized that the problem is complicated and successful detection of a pathogenic mutation frequently requires a combination of several methods and a knowledge of the biological phenomena associated with the corresponding macromolecules. PMID:24886813
[Advances in the physiopathology of epileptogenesis: metabolic aspects in vivo].
García-Segura, J M
This communication shows how proton magnetic resonance spectroscopy (MRS) is currently being employed in the study or the diagnosis of epilepsy. With this goal, the kind of biochemical information of cerebral parenchyma available with this non invasive technique is first introduced in a succinct way. The value of this metabolic information is then illustrated through several cases of temporal and extratemporal epilepsy, for which magnetic resonance imaging was either non diagnostic or uncertain. In this context, the asymmetry index, very useful for the lateralization of epileptogenic foci on the basis of quantitative spectroscopic criteria, is defined. Finally, other potentials of MRS, beyond its ability to elucidate the existence of neuronal damage in the epileptogenic zone, are considered. Hence, cases with postictally increased lactate, or increased glutamine/glutamate without apparent neuronal damage, are presented as good examples of the diagnostic or lateralizing value of MRS.
Doherty, Carolynne M; Forbes, Raeburn B
2014-01-01
Diagnostic Lumbar Puncture is one of the most commonly performed invasive tests in clinical medicine. Evaluation of an acute headache and investigation of inflammatory or infectious disease of the nervous system are the most common indications. Serious complications are rare, and correct technique will minimise diagnostic error and maximise patient comfort. We review the technique of diagnostic Lumbar Puncture including anatomy, needle selection, needle insertion, measurement of opening pressure, Cerebrospinal Fluid (CSF) specimen handling and after care. We also make some quality improvement suggestions for those designing services incorporating diagnostic Lumbar Puncture. PMID:25075138
Aerodynamic measurement techniques. [laser based diagnostic techniques
NASA Technical Reports Server (NTRS)
Hunter, W. W., Jr.
1976-01-01
Laser characteristics of intensity, monochromatic, spatial coherence, and temporal coherence were developed to advance laser based diagnostic techniques for aerodynamic related research. Two broad categories of visualization and optical measurements were considered, and three techniques received significant attention. These are holography, laser velocimetry, and Raman scattering. Examples of the quantitative laser velocimeter and Raman scattering measurements of velocity, temperature, and density indicated the potential of these nonintrusive techniques.
Novel diagnostic techniques for celiac disease.
Kurppa, Kalle; Taavela, Juha; Saavalainen, Päivi; Kaukinen, Katri; Lindfors, Katri
2016-07-01
The diagnosis of celiac disease has long been based on the demonstration of gluten-induced small-bowel mucosal damage. However, due to the constantly increasing disease prevalence and limitations in the histology-based criteria there is a pressure towards more serology-based diagnostics. The serological tools are being improved and new non-invasive methods are being developed, but the constantly refined endoscopic and histologic techniques may still prove helpful. Moreover, growing understanding of the disease pathogenesis has led researchers to suggest completely novel approaches to celiac disease diagnostics regardless of disease activity. In this review, we will elucidate the most recent development and possible future innovations in the diagnostic techniques for celiac disease.
Surface Diagnostics in Tribology Technology and Advanced Coatings Development
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa
1999-01-01
This paper discusses the methodologies used for surface property measurement of thin films and coatings, lubricants, and materials in the field of tribology. Surface diagnostic techniques include scanning electron microscopy, transmission electron microscopy, atomic force microscopy, stylus profilometry, x-ray diffraction, electron diffraction, Raman spectroscopy, Rutherford backscattering, elastic recoil spectroscopy, and tribology examination. Each diagnostic technique provides specific measurement results in its own unique way. In due course it should be possible to coordinate the different pieces of information provided by these diagnostic techniques into a coherent self-consistent description of the surface properties. Examples are given on the nature and character of thin diamond films.
FNA diagnostic value in patients with neck masses in two teaching hospitals in Iran.
Saatian, Minoo; Badie, Banafsheh Moradmand; Shahriari, Sogol; Fattahi, Fahimeh; Rasoolinejad, Mehrnaz
2011-01-01
The FNA (fine needle aspiration) procedure is simple, inexpensive, available and a safe method for the diagnosis of a neck mass. FNA has numerous advantages over open surgical biopsies as an initial diagnostic tool; therefore we decided to compare the accuracy of this method with open biopsy. This retrospective as well as descriptive study comparing preoperative FNA results with existing data in the Pathology Department in Bu-Ali and Amir Alam Hospitals. Our study included 100 patients with neck masses of which 22 were thyroid masses, 31 were salivary gland masses, and 47 were other masses. Age ranged from 3 years to 80 years with the mean age of 42.6 years. There were 59 men and 41 women. The Sensitivity was 72%, Specificity 87%, PPV 85%, NPV 75% and diagnostic Accuracy 79%. In this study we had also 26% false negative and 15% false positive. FNA is a valuable diagnostic tool in the management of neck masses; also it has been used for staging and planning of treatment for the wide and metastatic malignancy. This technique reduces the need for more invasive and costly procedures. According to the high sensitivity and high accuracy in this study, FNA can be used as the first step of diagnoses test in neck masses.
A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics
NASA Technical Reports Server (NTRS)
Kobayashi, Takahisa; Simon, Donald L.
2001-01-01
In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.
Using phase locking for improving frequency stability and tunability of THz-band gyrotrons
NASA Astrophysics Data System (ADS)
Adilova, Asel B.; Gerasimova, Svetlana A.; Melnikova, Maria M.; Tyshkun, Alexandra V.; Rozhnev, Andrey G.; Ryskin, Nikita M.
2018-04-01
Medium-power (10-100 W) THz-band gyrotrons operating in a continuous-wave (CW) mode are of great importance for many applications such as NMR spectroscopy with dynamic nuclear polarization (DNP/NMR), plasma diagnostics, nondestructive inspection, stand-off detection of radioactive materials, biomedical applications, etc. For all these applications, high frequency stability and tunability within 1-2 GHz frequency range is typically required. Apart from different existing techniques for frequency stabilization, phase locking has recently attracted strong interest. In this paper, we present the results of theoretical analysis and numerical simulation for several phase locking techniques: (a) phase locking by injection of the external driving signal; (b) mutual phase locking of two coupled gyrotrons; and (c) selfinjection locking by a wave reflected from the remote load.
Chapter 15: Disease Gene Prioritization
Bromberg, Yana
2013-01-01
Disease-causing aberrations in the normal function of a gene define that gene as a disease gene. Proving a causal link between a gene and a disease experimentally is expensive and time-consuming. Comprehensive prioritization of candidate genes prior to experimental testing drastically reduces the associated costs. Computational gene prioritization is based on various pieces of correlative evidence that associate each gene with the given disease and suggest possible causal links. A fair amount of this evidence comes from high-throughput experimentation. Thus, well-developed methods are necessary to reliably deal with the quantity of information at hand. Existing gene prioritization techniques already significantly improve the outcomes of targeted experimental studies. Faster and more reliable techniques that account for novel data types are necessary for the development of new diagnostics, treatments, and cure for many diseases. PMID:23633938
Population forecasts for Bangladesh, using a Bayesian methodology.
Mahsin, Md; Hossain, Syed Shahadat
2012-12-01
Population projection for many developing countries could be quite a challenging task for the demographers mostly due to lack of availability of enough reliable data. The objective of this paper is to present an overview of the existing methods for population forecasting and to propose an alternative based on the Bayesian statistics, combining the formality of inference. The analysis has been made using Markov Chain Monte Carlo (MCMC) technique for Bayesian methodology available with the software WinBUGS. Convergence diagnostic techniques available with the WinBUGS software have been applied to ensure the convergence of the chains necessary for the implementation of MCMC. The Bayesian approach allows for the use of observed data and expert judgements by means of appropriate priors, and a more realistic population forecasts, along with associated uncertainty, has been possible.
Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David
2017-01-01
Background Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. Methodology/Principal findings A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74–0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic to non-endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65–88%), compared to the sensitivity (91–100%) of the new molecular diagnostic workflow. Conclusions/Significance Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited. PMID:28915255
NASA Technical Reports Server (NTRS)
Pratt, D. T.
1984-01-01
An interactive computer code for simulation of a high-intensity turbulent combustor as a single point inhomogeneous stirred reactor was developed from an existing batch processing computer code CDPSR. The interactive CDPSR code was used as a guide for interpretation and direction of DOE-sponsored companion experiments utilizing Xenon tracer with optical laser diagnostic techniques to experimentally determine the appropriate mixing frequency, and for validation of CDPSR as a mixing-chemistry model for a laboratory jet-stirred reactor. The coalescence-dispersion model for finite rate mixing was incorporated into an existing interactive code AVCO-MARK I, to enable simulation of a combustor as a modular array of stirred flow and plug flow elements, each having a prescribed finite mixing frequency, or axial distribution of mixing frequency, as appropriate. Further increase the speed and reliability of the batch kinetics integrator code CREKID was increased by rewriting in vectorized form for execution on a vector or parallel processor, and by incorporating numerical techniques which enhance execution speed by permitting specification of a very low accuracy tolerance.
NASA Astrophysics Data System (ADS)
Rogatkin, Dmitrii A.; Tchernyi, Vladimir V.
2003-07-01
The optical noninvasive diagnostic systems are now widely applied and investigated in different areas of medicine. One of the such techniques is the noninvasive spectrophotometry, the complex diagnostic technique consisting on elastic scattering spectroscopy, absorption spectroscopy, fluorescent diagnostics, photoplethismography, etc. Today a lot of real optical diagnostic systems indicate the technical parameters and physical data only as a result of the diagnostic procedure. But, it is clear that for the medical staff the more convenient medical information is needed. This presentation lights the general way for development a diagnostic system"s software, which can produce the full processing of the diagnostic data from a physical to a medical level. It is shown, that this process is a multilevel (3-level) procedure and the main diagnostic result for noninvasive spectrophotometry methods, the biochemical and morphological composition of the tested tissues, arises in it on a second level of calculations.
Educational Diagnostic Assessment.
ERIC Educational Resources Information Center
Bejar, Isaac I.
1984-01-01
Approaches proposed for educational diagnostic assessment are reviewed and identified as deficit assessment and error analysis. The development of diagnostic instruments may require a reexamination of existing psychometric models and development of alternative ones. The psychometric and content demands of diagnostic assessment all but require test…
20 CFR 220.179 - Exceptions to medical improvement.
Code of Federal Regulations, 2012 CFR
2012-04-01
... on new or improved diagnostic or evaluative techniques the annuitant's impairment(s) is not as... methodologies and advances in medical and other diagnostic or evaluative techniques have given, and will...
20 CFR 220.179 - Exceptions to medical improvement.
Code of Federal Regulations, 2014 CFR
2014-04-01
... on new or improved diagnostic or evaluative techniques the annuitant's impairment(s) is not as... methodologies and advances in medical and other diagnostic or evaluative techniques have given, and will...
20 CFR 220.179 - Exceptions to medical improvement.
Code of Federal Regulations, 2010 CFR
2010-04-01
... on new or improved diagnostic or evaluative techniques the annuitant's impairment(s) is not as... methodologies and advances in medical and other diagnostic or evaluative techniques have given, and will...
20 CFR 220.179 - Exceptions to medical improvement.
Code of Federal Regulations, 2011 CFR
2011-04-01
... on new or improved diagnostic or evaluative techniques the annuitant's impairment(s) is not as... methodologies and advances in medical and other diagnostic or evaluative techniques have given, and will...
20 CFR 220.179 - Exceptions to medical improvement.
Code of Federal Regulations, 2013 CFR
2013-04-01
... on new or improved diagnostic or evaluative techniques the annuitant's impairment(s) is not as... methodologies and advances in medical and other diagnostic or evaluative techniques have given, and will...
NASA Astrophysics Data System (ADS)
Ganesh, Shruthi Vatsyayani
With the advent of microfluidic technologies for molecular diagnostics, a lot of emphasis has been placed on developing diagnostic tools for resource poor regions in the form of Extreme Point of Care devices. To ensure commercial viability of such a device there is a need to develop an accurate sample to answer system, which is robust, portable, isolated yet highly sensitive and cost effective. This need has been a driving force for research involving integration of different microsystems like droplet microfluidics, Compact-disc (CD)microfluidics along with sample preparation and detection modules on a single platform. This work attempts to develop a proof of concept prototype of one such device using existing CD microfluidics tools to generate stable droplets used in point of care diagnostics (POC diagnostics). Apart from using a fairly newer technique for droplet generation and stabilization, the work aims to develop this method focused towards diagnostics for rural healthcare. The motivation for this work is first described with an emphasis on the current need for diagnostic testing in rural health-care and the general guidelines prescribed by WHO for such a sample to answer system. Furthermore, a background on CD and droplet microfluidics is presented to understand the merits and de-merits of each system and the need for integrating the two. This phase of the thesis also includes different methods employed/demonstrated to generate droplets on a spinning platform. An overview on the detection platforms is also presented to understand the challenges involved in building an extreme point of care device. In the third phase of the thesis, general manufacturing techniques and materials used to accomplish this work is presented. Lastly, design trials for droplet generation is presented. The shortcomings of these trials are solved by investigating mechanisms pertaining to design modification and use of agarose based droplet generation to ensure a more robust sample processing method. This method is further characterized and compared with non-agarose based system and the results are analyzed. In conclusion, future prospects of this work are discussed in relation to extreme POC applications.
The Validity of Projective Techniques and Their Clinical and Research Contributions
ERIC Educational Resources Information Center
Blatt, Sidney J.
1975-01-01
Questions about the limitations and potential contributions of projective techniques in research are considered and issues which limit the contributions of diagnostic assessment and projective techniques in clinical practice are examined. A proposal is made for conceptualizing diagnostic assessment as a more integral part of the therapeutic…
Quigley, Elizabeth A; Tokay, Barbara A; Jewell, Sarah T; Marchetti, Michael A; Halpern, Allan C
2015-08-01
Photographs are invaluable dermatologic diagnostic, management, research, teaching, and documentation tools. Digital Imaging and Communications in Medicine (DICOM) standards exist for many types of digital medical images, but there are no DICOM standards for camera-acquired dermatologic images to date. To identify and describe existing or proposed technology and technique standards for camera-acquired dermatologic images in the scientific literature. Systematic searches of the PubMed, EMBASE, and Cochrane databases were performed in January 2013 using photography and digital imaging, standardization, and medical specialty and medical illustration search terms and augmented by a gray literature search of 14 websites using Google. Two reviewers independently screened titles of 7371 unique publications, followed by 3 sequential full-text reviews, leading to the selection of 49 publications with the most recent (1985-2013) or detailed description of technology or technique standards related to the acquisition or use of images of skin disease (or related conditions). No universally accepted existing technology or technique standards for camera-based digital images in dermatology were identified. Recommendations are summarized for technology imaging standards, including spatial resolution, color resolution, reproduction (magnification) ratios, postacquisition image processing, color calibration, compression, output, archiving and storage, and security during storage and transmission. Recommendations are also summarized for technique imaging standards, including environmental conditions (lighting, background, and camera position), patient pose and standard view sets, and patient consent, privacy, and confidentiality. Proposed standards for specific-use cases in total body photography, teledermatology, and dermoscopy are described. The literature is replete with descriptions of obtaining photographs of skin disease, but universal imaging standards have not been developed, validated, and adopted to date. Dermatologic imaging is evolving without defined standards for camera-acquired images, leading to variable image quality and limited exchangeability. The development and adoption of universal technology and technique standards may first emerge in scenarios when image use is most associated with a defined clinical benefit.
Yimer, Mulat; Hailu, Tadesse; Mulu, Wondemagegn; Abera, Bayeh
2015-12-26
Although the sensitivity of Wet mount technique is questionable, it is the major diagnostic technique for routine diagnosis of intestinal parasitosis in Ethiopia. Therefore, the aim of this study was the evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia. A cross sectional study was conducted from May to June 2013. Single stool sample was processed for direct, Formol ether concentration (FEC) and Kato Katz methods. The sensitivity and negative predictive value (NPV) of diagnostic tests were calculated in terms of the "Gold" standard method (the combined result of the three methods altogether). A total of 422 school age children were participated in this study. The prevalence of intestinal parasites was high (74.6%) with Kato Katz technique. The sensitivity of Wet mount, FEC and Kato Katz tests against the Gold standard test was 48.9, 63.1 and 93.7%, respectively. Kato Katz technique revealed a better NPV 80.4 (80.1-80.6) as compared to the Wet mount (33.7%) and FEC techniques (41.3%). In this study, the Kato Katz technique outperformed the other two methods but the true values for sensitivity, specificity and diagnostic values are not known. Moreover, it is labor intensive and not easily accessible. Hence, it is preferable to use FEC technique to complement the Wet mount test.
[Advances of Molecular Diagnostic Techniques Application in Clinical Diagnosis.
Ying, Bin-Wu
2016-11-01
Over the past 20 years,clinical molecular diagnostic technology has made rapid development,and became the most promising field in clinical laboratory medicine.In particular,with the development of genomics,clinical molecular diagnostic methods will reveal the nature of clinical diseases in a deeper level,thus guiding the clinical diagnosis and treatments.Many molecular diagnostic projects have been routinely applied in clinical works.This paper reviews the advances on application of clinical diagnostic techniques in infectious disease,tumor and genetic disorders,including nucleic acid amplification,biochip,next-generation sequencing,and automation molecular system,and so on.
Noncontact techniques for diesel engine diagnostics using exhaust waveform analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gore, D.A.; Cooke, G.J.
1987-01-01
RCA Corporation's continuing efforts to develop noncontact test techniques for diesel engines have led to recent advancements in deep engine diagnostics. The U.S. Army Tank-Automotive Command (TACOM) has been working with RCA for the development of new noncontact sensors and test techniques which use these sensors in conjunction with their family of Simplified Test Equipment (STE) to perform vehicle diagnostics. The STE systems are microprocessor-based maintenance tools that assist the Army mechanic in diagnosing malfunctions in both tactical and combat vehicles. The test systems support the mechanic by providing the sophisticated signal processing capabilities necessary for a wide range ofmore » diagnostic testing including exhaust waveform analysis.« less
NASA Astrophysics Data System (ADS)
Adam Rebeles, R.; Van den Winkel, P.; Hermanne, A.; Tárkányi, F.
2009-02-01
One of the radioisotopes for which a growing interest exists in nuclear medicine is 64Cu. Its branched decay makes it suitable for both diagnostic and therapeutic purposes. Activation cross sections of the proton induced reaction on enriched 64Ni have been studied using the stacked foil technique up to 24 MeV. The experimental cross sections are compared with values available from literature. Thick target yields, based on the discrete measured values of the cross sections are calculated and allow a better estimation of the optimum production parameters.
Paper-based analytical devices for environmental analysis.
Meredith, Nathan A; Quinn, Casey; Cate, David M; Reilly, Thomas H; Volckens, John; Henry, Charles S
2016-03-21
The field of paper-based microfluidics has experienced rapid growth over the past decade. Microfluidic paper-based analytical devices (μPADs), originally developed for point-of-care medical diagnostics in resource-limited settings, are now being applied in new areas, such as environmental analyses. Low-cost paper sensors show great promise for on-site environmental analysis; the theme of ongoing research complements existing instrumental techniques by providing high spatial and temporal resolution for environmental monitoring. This review highlights recent applications of μPADs for environmental analysis along with technical advances that may enable μPADs to be more widely implemented in field testing.
Policy analysis for prenatal genetic diagnosis.
Thompson, M; Milunsky, A
1979-01-01
Consideration of the analytic difficulties faced in estimating the benefits and costs of prenatal genetic diagnosis, coupled with a brief review of existing benefit-cost studies, leads to the conclusion that public subsidy of prenatal testing can yield benefits substantially in excess of costs. The practical obstacles to such programs include the attitudes of prospective parents, a lack of knowledge, monetary barriers, inadequately organized medical resources, and the political issue of abortion. Policy analysis can now nevertheless formulate principles and guide immediate actions to improve present utilization of prenatal testing and to facilitate possible future expansion of these diagnostic techniques.
Krauss, J K; Halve, B
2004-04-01
There is no agreement on the best diagnostic criteria for selecting patients with normal pressure hydrocephalus (NPH) for CSF shunting. The primary objective of the present study was to provide a contemporary survey on diagnostic algorithms and therapeutic decision-making in clinical practice. The secondary objective was to estimate the incidence of NPH. Standardized questionnaires with sections on the incidence of NPH and the frequency of shunting, evaluation of clinical symptoms, and signs, diagnostic studies, therapeutic decision-making and operative techniques, postoperative outcome and complications, and the profiles of different centers, were sent to 82 neurosurgical centers in Germany known to participate in the care of patients with NPH. Data were analyzed from 49 of 53 centers which responded to the survey (65%). The estimated annual incidence of NPH was 1.8 cases/100.000 inhabitants. Gait disturbance was defined as the most important sign of NPH (61%). There was a wide variety in the choice of diagnostic tests. Cisternography was performed routinely only in single centers. Diagnostic CSF removal was used with varying frequency by all centers except one, but the amount of CSF removed by lumbar puncture differed markedly between centers. There was poor agreement on criteria for evaluation of continuous intracranial pressure recordings regarding both the amplitude and the relative frequency of B-waves. Both periventricular and deep white matter lesions were present in about 50% of patients being shunted, indicating that vascular comorbidity in NPH patients has gained more acceptance. Programmable shunts were used by more than half of the centers, and newer valve types such as gravitational valves have become more popular. According to the present survey, new diagnostic and therapeutic concepts on NPH have penetrated daily routine to a certain extent. Wide variability, however, still exists among different neurosurgical centers.
Diagnostic testing for Giardia infections.
Heyworth, Martin F
2014-03-01
The traditional method for diagnosing Giardia infections involves microscopic examination of faecal specimens for Giardia cysts. This method is subjective and relies on observer experience. From the 1980s onwards, objective techniques have been developed for diagnosing Giardia infections, and are superseding diagnostic techniques reliant on microscopy. Detection of Giardia antigen(s) by immunoassay is the basis of commercially available diagnostic kits. Various nucleic acid amplification techniques (NAATs) can demonstrate DNA of Giardia intestinalis, and have the potential to become standard approaches for diagnosing Giardia infections. Of such techniques, methods involving either fluorescent microspheres (Luminex) or isothermal amplification of DNA (loop-mediated isothermal amplification; LAMP) are especially promising.
Uhlig, Johannes; Uhlig, Annemarie; Kunze, Meike; Beissbarth, Tim; Fischer, Uwe; Lotz, Joachim; Wienbeck, Susanne
2018-05-24
The purpose of this study is to evaluate the diagnostic performance of machine learning techniques for malignancy prediction at breast cone-beam CT (CBCT) and to compare them to human readers. Five machine learning techniques, including random forests, back propagation neural networks (BPN), extreme learning machines, support vector machines, and K-nearest neighbors, were used to train diagnostic models on a clinical breast CBCT dataset with internal validation by repeated 10-fold cross-validation. Two independent blinded human readers with profound experience in breast imaging and breast CBCT analyzed the same CBCT dataset. Diagnostic performance was compared using AUC, sensitivity, and specificity. The clinical dataset comprised 35 patients (American College of Radiology density type C and D breasts) with 81 suspicious breast lesions examined with contrast-enhanced breast CBCT. Forty-five lesions were histopathologically proven to be malignant. Among the machine learning techniques, BPNs provided the best diagnostic performance, with AUC of 0.91, sensitivity of 0.85, and specificity of 0.82. The diagnostic performance of the human readers was AUC of 0.84, sensitivity of 0.89, and specificity of 0.72 for reader 1 and AUC of 0.72, sensitivity of 0.71, and specificity of 0.67 for reader 2. AUC was significantly higher for BPN when compared with both reader 1 (p = 0.01) and reader 2 (p < 0.001). Machine learning techniques provide a high and robust diagnostic performance in the prediction of malignancy in breast lesions identified at CBCT. BPNs showed the best diagnostic performance, surpassing human readers in terms of AUC and specificity.
NASA Astrophysics Data System (ADS)
Hu, Jianqiang; Liu, Ahdi; Zhou, Chu; Zhang, Xiaohui; Wang, Mingyuan; Zhang, Jin; Feng, Xi; Li, Hong; Xie, Jinlin; Liu, Wandong; Yu, Changxuan
2017-08-01
A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehensive scanning system, we can realize not only automatic but also fast and accurate measurement, which will help to eliminate the effects of temperature drift and standing wave/multi-reflection. With the Matlab-based asymmetric two-dimensional Gaussian fitting method, all the desired parameters of the microwave beam can be obtained. This technique can be used in the design and testing of microwave diagnostic systems such as reflectometers and the electron cyclotron emission imaging diagnostic systems of the Experimental Advanced Superconducting Tokamak.
Multi-dimensional optical and laser-based diagnostics of low-temperature ionized plasma discharges
Barnat, Edward V.
2011-09-15
In this paper, a review of work centered on the utilization of multi-dimensional optical diagnostics to study phenomena arising in radiofrequency plasma discharges is given. The diagnostics range from passive techniques such as optical emission to more active techniques utilizing nanosecond lasers capable of both high temporal and spatial resolution. In this review, emphasis is placed on observations that would have been more difficult, if not impossible, to make without the use of such diagnostic techniques. Examples include the sheath structure around an electrode consisting of two different metals, double layers that arise in magnetized hydrogen discharges, or a largemore » region of depleted argon 1s 4 levels around a biased probe in an rf discharge.« less
New diagnostic technique for the study of turbulent boundary-layer separation
NASA Technical Reports Server (NTRS)
Horstman, C. C.; Owen, F. K.
1974-01-01
Description of a diagnostic technique for determining the unsteady character of turbulent boundary-layer separation. The technique uses thin platinum films mounted flush with the model surface. Voltages from these films provide measurements related to the flow character above the film. For illustration, results obtained by this technique are presented for the interaction of a hypersonic shock wave and a turbulent boundary layer, with and without separation.
Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities
NASA Technical Reports Server (NTRS)
Grinstead, Jay H.; Wilder, Michael C.; Porter, Barry J.; Brown, Jeffrey D.; Yeung, Dickson; Battazzo, Stephen J.; Brubaker, Timothy R.
2016-01-01
The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. Use of TALIF expanded at NASA Ames and to NASA Johnson's arc jet facility in the late 2000s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the original AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper documents the overall system design from measurement requirements to implementation. Representative data from the redeveloped AHF and IHF LIF systems are also presented.
NASA Astrophysics Data System (ADS)
Shen, Fei; Chen, Chao; Yan, Ruqiang
2017-05-01
Classical bearing fault diagnosis methods, being designed according to one specific task, always pay attention to the effectiveness of extracted features and the final diagnostic performance. However, most of these approaches suffer from inefficiency when multiple tasks exist, especially in a real-time diagnostic scenario. A fault diagnosis method based on Non-negative Matrix Factorization (NMF) and Co-clustering strategy is proposed to overcome this limitation. Firstly, some high-dimensional matrixes are constructed using the Short-Time Fourier Transform (STFT) features, where the dimension of each matrix equals to the number of target tasks. Then, the NMF algorithm is carried out to obtain different components in each dimension direction through optimized matching, such as Euclidean distance and divergence distance. Finally, a Co-clustering technique based on information entropy is utilized to realize classification of each component. To verity the effectiveness of the proposed approach, a series of bearing data sets were analysed in this research. The tests indicated that although the diagnostic performance of single task is comparable to traditional clustering methods such as K-mean algorithm and Guassian Mixture Model, the accuracy and computational efficiency in multi-tasks fault diagnosis are improved.
Perspectives of gene expression profiling for diagnosis and therapy in haematological malignancies.
Bacher, Ulrike; Kohlmann, Alexander; Haferlach, Torsten
2009-05-01
Considering the heterogeneity of leukaemias and the widening spectrum of therapeutic strategies, novel diagnostic methods are urgently needed for haematological malignancies. For a decade, gene expression profiling (GEP) has been applied in leukaemia research. Thus, various studies demonstrated worldwide that the majority of genetically defined leukaemia subtypes are accurately predictable by GEP, for example, with respect to reciprocal rearrangements in acute myeloid leukaemia (AML). Moreover, novel prognostically relevant gene classifiers were developed as, for example, in normal karyotype AML. Considering the lymphatic malignancies, GEP studies defined novel clinically relevant subtypes in diffuse large B cell lymphoma (DLBCL), and improved the discrimination of Burkitt lymphoma and DLBCL cases, overcoming considerable overlaps of these entities that exist from morphological and genetic perspectives. Treatment-specific sensitivity assays are being developed for targeted drugs such as farnesyl transferase inhibitors in AML or imatinib in BCR-ABL1 positive acute lymphoblastic leukaemia (ALL). Irrespectively of these proceedings, an introduction of the microarray technology in haematological practice requires diagnostic algorithms and strategies for interaction with currently established diagnostic techniques. Large multicentre studies such as the MILE Study (Microarray Innovations in LEukemia) aim at translating this methodology into clinical routine workflows and to catalyze this process.
Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities
NASA Technical Reports Server (NTRS)
Grinstead, Jay; Wilder, Michael C.; Porter, Barry; Brown, Jeff; Yeung, Dickson; Battazzo, Steve; Brubaker, Tim
2016-01-01
The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. Use of TALIF expanded at NASA Ames and to NASA Johnsons arc jet facility in the late 2000s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the original AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper documents the overall system design from measurement requirements to implementation. Representative data from the redeveloped AHF and IHF LIF systems are also presented.
Software for enhanced video capsule endoscopy: challenges for essential progress.
Iakovidis, Dimitris K; Koulaouzidis, Anastasios
2015-03-01
Video capsule endoscopy (VCE) has revolutionized the diagnostic work-up in the field of small bowel diseases. Furthermore, VCE has the potential to become the leading screening technique for the entire gastrointestinal tract. Computational methods that can be implemented in software can enhance the diagnostic yield of VCE both in terms of efficiency and diagnostic accuracy. Since the appearance of the first capsule endoscope in clinical practice in 2001, information technology (IT) research groups have proposed a variety of such methods, including algorithms for detecting haemorrhage and lesions, reducing the reviewing time, localizing the capsule or lesion, assessing intestinal motility, enhancing the video quality and managing the data. Even though research is prolific (as measured by publication activity), the progress made during the past 5 years can only be considered as marginal with respect to clinically significant outcomes. One thing is clear-parallel pathways of medical and IT scientists exist, each publishing in their own area, but where do these research pathways meet? Could the proposed IT plans have any clinical effect and do clinicians really understand the limitations of VCE software? In this Review, we present an in-depth critical analysis that aims to inspire and align the agendas of the two scientific groups.
20 CFR 404.1594 - How we will determine whether your disability continues or ends.
Code of Federal Regulations, 2011 CFR
2011-04-01
... diagnostic or evaluative techniques your impairment(s) is not as disabling as it was considered to be at the... diagnostic or evaluative techniques have given, and will continue to give, rise to improved methods for... evaluative techniques. Such listings changes will clearly state this fact as they are published as Notices of...
20 CFR 404.1594 - How we will determine whether your disability continues or ends.
Code of Federal Regulations, 2014 CFR
2014-04-01
... diagnostic or evaluative techniques your impairment(s) is not as disabling as it was considered to be at the... diagnostic or evaluative techniques have given, and will continue to give, rise to improved methods for... evaluative techniques. Such listings changes will clearly state this fact as they are published as Notices of...
20 CFR 404.1594 - How we will determine whether your disability continues or ends.
Code of Federal Regulations, 2013 CFR
2013-04-01
... diagnostic or evaluative techniques your impairment(s) is not as disabling as it was considered to be at the... diagnostic or evaluative techniques have given, and will continue to give, rise to improved methods for... evaluative techniques. Such listings changes will clearly state this fact as they are published as Notices of...
20 CFR 404.1594 - How we will determine whether your disability continues or ends.
Code of Federal Regulations, 2010 CFR
2010-04-01
... diagnostic or evaluative techniques your impairment(s) is not as disabling as it was considered to be at the... diagnostic or evaluative techniques have given, and will continue to give, rise to improved methods for... evaluative techniques. Such listings changes will clearly state this fact as they are published as Notices of...
20 CFR 404.1594 - How we will determine whether your disability continues or ends.
Code of Federal Regulations, 2012 CFR
2012-04-01
... diagnostic or evaluative techniques your impairment(s) is not as disabling as it was considered to be at the... diagnostic or evaluative techniques have given, and will continue to give, rise to improved methods for... evaluative techniques. Such listings changes will clearly state this fact as they are published as Notices of...
Cell-free fetal nucleic acid testing: a review of the technology and its applications.
Sayres, Lauren C; Cho, Mildred K
2011-07-01
Cell-free fetal nucleic acids circulating in the blood of pregnant women afford the opportunity for early, noninvasive prenatal genetic testing. The predominance of admixed maternal genetic material in circulation demands innovative means for identification and analysis of cell-free fetal DNA and RNA. Techniques using polymerase chain reaction, mass spectrometry, and sequencing have been developed for the purposes of detecting fetal-specific sequences, such as paternally inherited or de novo mutations, or determining allelic balance or chromosome dosage. Clinical applications of these methods include fetal sex determination and blood group typing, which are currently available commercially although not offered routinely in the United States. Other uses of cell-free fetal DNA and RNA being explored are the detection of single-gene disorders, chromosomal abnormalities, and inheritance of parental polymorphisms across the whole fetal genome. The concentration of cell-free fetal DNA may also provide predictive capabilities for pregnancy-associated complications. The roles that cell-free fetal nucleic acid testing assume in the existing framework of prenatal screening and invasive diagnostic testing will depend on factors such as costs, clinical validity and utility, and perceived benefit-risk ratios for different applications. As cell-free fetal DNA and RNA testing continues to be developed and translated, significant ethical, legal, and social questions will arise that will need to be addressed by those with a stake in the use of this technology. Obstetricians & Gynecologists and Family Physicians Learning Objectives: After participating in this activity, physicians should be better able to evaluate techniques and tools for analyzing cell-free fetal nucleic acids, assess clinical applications of prenatal testing, using cell-free fetal nucleic acids and barriers to implementation, and distinguish between relevant clinical features of cell-free fetal nucleic acid testing and existing prenatal genetic screening and diagnostic procedures.
Reflectometric measurement of plasma imaging and applications
NASA Astrophysics Data System (ADS)
Mase, A.; Ito, N.; Oda, M.; Komada, Y.; Nagae, D.; Zhang, D.; Kogi, Y.; Tobimatsu, S.; Maruyama, T.; Shimazu, H.; Sakata, E.; Sakai, F.; Kuwahara, D.; Yoshinaga, T.; Tokuzawa, T.; Nagayama, Y.; Kawahata, K.; Yamaguchi, S.; Tsuji-Iio, S.; Domier, C. W.; Luhmann, N. C., Jr.; Park, H. K.; Yun, G.; Lee, W.; Padhi, S.; Kim, K. W.
2012-01-01
Progress in microwave and millimeter-wave technologies has made possible advanced diagnostics for application to various fields, such as, plasma diagnostics, radio astronomy, alien substance detection, airborne and spaceborne imaging radars called as synthetic aperture radars, living body measurements. Transmission, reflection, scattering, and radiation processes of electromagnetic waves are utilized as diagnostic tools. In this report we focus on the reflectometric measurements and applications to biological signals (vital signal detection and breast cancer detection) as well as plasma diagnostics, specifically by use of imaging technique and ultra-wideband radar technique.
What We Do and Do Not Know about Teaching Medical Image Interpretation.
Kok, Ellen M; van Geel, Koos; van Merriënboer, Jeroen J G; Robben, Simon G F
2017-01-01
Educators in medical image interpretation have difficulty finding scientific evidence as to how they should design their instruction. We review and comment on 81 papers that investigated instructional design in medical image interpretation. We distinguish between studies that evaluated complete offline courses and curricula, studies that evaluated e-learning modules, and studies that evaluated specific educational interventions. Twenty-three percent of all studies evaluated the implementation of complete courses or curricula, and 44% of the studies evaluated the implementation of e-learning modules. We argue that these studies have encouraging results but provide little information for educators: too many differences exist between conditions to unambiguously attribute the learning effects to specific instructional techniques. Moreover, concepts are not uniformly defined and methodological weaknesses further limit the usefulness of evidence provided by these studies. Thirty-two percent of the studies evaluated a specific interventional technique. We discuss three theoretical frameworks that informed these studies: diagnostic reasoning, cognitive schemas and study strategies. Research on diagnostic reasoning suggests teaching students to start with non-analytic reasoning and subsequently applying analytic reasoning, but little is known on how to train non-analytic reasoning. Research on cognitive schemas investigated activities that help the development of appropriate cognitive schemas. Finally, research on study strategies supports the effectiveness of practice testing, but more study strategies could be applicable to learning medical image interpretation. Our commentary highlights the value of evaluating specific instructional techniques, but further evidence is required to optimally inform educators in medical image interpretation.
Melanoma recognition framework based on expert definition of ABCD for dermoscopic images.
Abbas, Qaisar; Emre Celebi, M; Garcia, Irene Fondón; Ahmad, Waqar
2013-02-01
Melanoma Recognition based on clinical ABCD rule is widely used for clinical diagnosis of pigmented skin lesions in dermoscopy images. However, the current computer-aided diagnostic (CAD) systems for classification between malignant and nevus lesions using the ABCD criteria are imperfect due to use of ineffective computerized techniques. In this study, a novel melanoma recognition system (MRS) is presented by focusing more on extracting features from the lesions using ABCD criteria. The complete MRS system consists of the following six major steps: transformation to the CIEL*a*b* color space, preprocessing to enhance the tumor region, black-frame and hair artifacts removal, tumor-area segmentation, quantification of feature using ABCD criteria and normalization, and finally feature selection and classification. The MRS system for melanoma-nevus lesions is tested on a total of 120 dermoscopic images. To test the performance of the MRS diagnostic classifier, the area under the receiver operating characteristics curve (AUC) is utilized. The proposed classifier achieved a sensitivity of 88.2%, specificity of 91.3%, and AUC of 0.880. The experimental results show that the proposed MRS system can accurately distinguish between malignant and benign lesions. The MRS technique is fully automatic and can easily integrate to an existing CAD system. To increase the classification accuracy of MRS, the CASH pattern recognition technique, visual inspection of dermatologist, contextual information from the patients, and the histopathological tests can be included to investigate the impact with this system. © 2012 John Wiley & Sons A/S.
A Fault Alarm and Diagnosis Method Based on Sensitive Parameters and Support Vector Machine
NASA Astrophysics Data System (ADS)
Zhang, Jinjie; Yao, Ziyun; Lv, Zhiquan; Zhu, Qunxiong; Xu, Fengtian; Jiang, Zhinong
2015-08-01
Study on the extraction of fault feature and the diagnostic technique of reciprocating compressor is one of the hot research topics in the field of reciprocating machinery fault diagnosis at present. A large number of feature extraction and classification methods have been widely applied in the related research, but the practical fault alarm and the accuracy of diagnosis have not been effectively improved. Developing feature extraction and classification methods to meet the requirements of typical fault alarm and automatic diagnosis in practical engineering is urgent task. The typical mechanical faults of reciprocating compressor are presented in the paper, and the existing data of online monitoring system is used to extract fault feature parameters within 15 types in total; the inner sensitive connection between faults and the feature parameters has been made clear by using the distance evaluation technique, also sensitive characteristic parameters of different faults have been obtained. On this basis, a method based on fault feature parameters and support vector machine (SVM) is developed, which will be applied to practical fault diagnosis. A better ability of early fault warning has been proved by the experiment and the practical fault cases. Automatic classification by using the SVM to the data of fault alarm has obtained better diagnostic accuracy.
Multi-physics damage sensing in nano-engineered structural composites.
de Villoria, Roberto Guzmán; Yamamoto, Namiko; Miravete, Antonio; Wardle, Brian L
2011-05-06
Non-destructive evaluation techniques can offer viable diagnostic and prognostic routes to mitigating failures in engineered structures such as bridges, buildings and vehicles. However, existing techniques have significant drawbacks, including poor spatial resolution and limited in situ capabilities. We report here a novel approach where structural advanced composites containing electrically conductive aligned carbon nanotubes (CNTs) are ohmically heated via simple electrical contacts, and damage is visualized via thermographic imaging. Damage, in the form of cracks and other discontinuities, usefully increases resistance to both electrical and thermal transport in these materials, which enables tomographic full-field damage assessment in many cases. Characteristics of the technique include the ability for real-time measurement of the damage state during loading, low-power operation (e.g. 15 °C rise at 1 W), and beyond state-of-the-art spatial resolution for sensing damage in composites. The enhanced thermographic technique is a novel and practical approach for in situ monitoring to ascertain structural health and to prevent structural failures in engineered structures such as aerospace and automotive vehicles and wind turbine blades, among others.
Multi-physics damage sensing in nano-engineered structural composites
NASA Astrophysics Data System (ADS)
Guzmán de Villoria, Roberto; Yamamoto, Namiko; Miravete, Antonio; Wardle, Brian L.
2011-05-01
Non-destructive evaluation techniques can offer viable diagnostic and prognostic routes to mitigating failures in engineered structures such as bridges, buildings and vehicles. However, existing techniques have significant drawbacks, including poor spatial resolution and limited in situ capabilities. We report here a novel approach where structural advanced composites containing electrically conductive aligned carbon nanotubes (CNTs) are ohmically heated via simple electrical contacts, and damage is visualized via thermographic imaging. Damage, in the form of cracks and other discontinuities, usefully increases resistance to both electrical and thermal transport in these materials, which enables tomographic full-field damage assessment in many cases. Characteristics of the technique include the ability for real-time measurement of the damage state during loading, low-power operation (e.g. 15 °C rise at 1 W), and beyond state-of-the-art spatial resolution for sensing damage in composites. The enhanced thermographic technique is a novel and practical approach for in situ monitoring to ascertain structural health and to prevent structural failures in engineered structures such as aerospace and automotive vehicles and wind turbine blades, among others.
Prediction of quantitative intrathoracic fluid volume to diagnose pulmonary oedema using LabVIEW.
Urooj, Shabana; Khan, M; Ansari, A Q; Lay-Ekuakille, Aimé; Salhan, Ashok K
2012-01-01
Pulmonary oedema is a life-threatening disease that requires special attention in the area of research and clinical diagnosis. Computer-based techniques are rarely used to quantify the intrathoracic fluid volume (IFV) for diagnostic purposes. This paper discusses a software program developed to detect and diagnose pulmonary oedema using LabVIEW. The software runs on anthropometric dimensions and physiological parameters, mainly transthoracic electrical impedance (TEI). This technique is accurate and faster than existing manual techniques. The LabVIEW software was used to compute the parameters required to quantify IFV. An equation relating per cent control and IFV was obtained. The results of predicted TEI and measured TEI were compared with previously reported data to validate the developed program. It was found that the predicted values of TEI obtained from the computer-based technique were much closer to the measured values of TEI. Six new subjects were enrolled to measure and predict transthoracic impedance and hence to quantify IFV. A similar difference was also observed in the measured and predicted values of TEI for the new subjects.
Novel Strategy to Evaluate Infectious Salmon Anemia Virus Variants by High Resolution Melting
Sepúlveda, Dagoberto; Cárdenas, Constanza; Carmona, Marisela; Marshall, Sergio H.
2012-01-01
Genetic variability is a key problem in the prevention and therapy of RNA-based virus infections. Infectious Salmon Anemia virus (ISAv) is an RNA virus which aggressively attacks salmon producing farms worldwide and in particular in Chile. Just as with most of the Orthomyxovirus, ISAv displays high variability in its genome which is reflected by a wider infection potential, thus hampering management and prevention of the disease. Although a number of widely validated detection procedures exist, in this case there is a need of a more complex approach to the characterization of virus variability. We have adapted a procedure of High Resolution Melting (HRM) as a fine-tuning technique to fully differentiate viral variants detected in Chile and projected to other infective variants reported elsewhere. Out of the eight viral coding segments, the technique was adapted using natural Chilean variants for two of them, namely segments 5 and 6, recognized as virulence-associated factors. Our work demonstrates the versatility of the technique as well as its superior resolution capacity compared with standard techniques currently in use as key diagnostic tools. PMID:22719837
Danly, C R; Day, T H; Fittinghoff, D N; Herrmann, H; Izumi, N; Kim, Y H; Martinez, J I; Merrill, F E; Schmidt, D W; Simpson, R A; Volegov, P L; Wilde, C H
2015-04-01
Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstrated on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. The technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Danly, C. R.; Day, T. H.; Fittinghoff, D. N.
Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstratedmore » on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. Thus, the technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Danly, C. R.; Day, T. H.; Herrmann, H.
Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstratedmore » on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. The technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.« less
Danly, C. R.; Day, T. H.; Fittinghoff, D. N.; ...
2015-04-16
Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstratedmore » on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. Thus, the technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.« less
20 CFR 416.994 - How we will determine whether your disability continues or ends, disabled adults.
Code of Federal Regulations, 2010 CFR
2010-04-01
... or improved diagnostic or evaluative techniques your impairment(s) is not as disabling as it was... medical and other diagnostic or evaluative techniques have given, and will continue to give, rise to...
20 CFR 416.994 - How we will determine whether your disability continues or ends, disabled adults.
Code of Federal Regulations, 2013 CFR
2013-04-01
... or improved diagnostic or evaluative techniques your impairment(s) is not as disabling as it was... medical and other diagnostic or evaluative techniques have given, and will continue to give, rise to...
20 CFR 416.994 - How we will determine whether your disability continues or ends, disabled adults.
Code of Federal Regulations, 2014 CFR
2014-04-01
... or improved diagnostic or evaluative techniques your impairment(s) is not as disabling as it was... medical and other diagnostic or evaluative techniques have given, and will continue to give, rise to...
20 CFR 416.994 - How we will determine whether your disability continues or ends, disabled adults.
Code of Federal Regulations, 2012 CFR
2012-04-01
... or improved diagnostic or evaluative techniques your impairment(s) is not as disabling as it was... medical and other diagnostic or evaluative techniques have given, and will continue to give, rise to...
20 CFR 416.994 - How we will determine whether your disability continues or ends, disabled adults.
Code of Federal Regulations, 2011 CFR
2011-04-01
... or improved diagnostic or evaluative techniques your impairment(s) is not as disabling as it was... medical and other diagnostic or evaluative techniques have given, and will continue to give, rise to...
Ren, Guomin; Krawetz, Roman
2015-01-01
The data explosion in the last decade is revolutionizing diagnostics research and the healthcare industry, offering both opportunities and challenges. These high-throughput "omics" techniques have generated more scientific data in the last few years than in the entire history of mankind. Here we present a brief summary of how "big data" have influenced early diagnosis of complex diseases. We will also review some of the most commonly used "omics" techniques and their applications in diagnostics. Finally, we will discuss the issues brought by these new techniques when translating laboratory discoveries to clinical practice.
Kocan, R.; Dolan, H.; Hershberger, P.
2011-01-01
Several different techniques have been employed to detect and identify Ichthyophonus spp. in infected fish hosts; these include macroscopic observation, microscopic examination of tissue squashes, histological evaluation, in vitro culture, and molecular techniques. Examination of the peer-reviewed literature revealed that when more than 1 diagnostic method is used, they often result in significantly different results; for example, when in vitro culture was used to identify infected trout in an experimentally exposed population, 98.7% of infected trout were detected, but when standard histology was used to confirm known infected tissues from wild salmon, it detected ~50% of low-intensity infections and ~85% of high-intensity infections. Other studies on different species reported similar differences. When we examined a possible mechanism to explain the disparity between different diagnostic techniques, we observed non-random distribution of the parasite in 3-dimensionally visualized tissue sections from infected hosts, thus providing a possible explanation for the different sensitivities of commonly used diagnostic techniques. Based on experimental evidence and a review of the peer-reviewed literature, we have concluded that in vitro culture is currently the most accurate diagnostic technique for determining infection prevalence of Ichthyophonus, particularly when the exposure history of the population is not known.
A design and implementation methodology for diagnostic systems
NASA Technical Reports Server (NTRS)
Williams, Linda J. F.
1988-01-01
A methodology for design and implementation of diagnostic systems is presented. Also discussed are the advantages of embedding a diagnostic system in a host system environment. The methodology utilizes an architecture for diagnostic system development that is hierarchical and makes use of object-oriented representation techniques. Additionally, qualitative models are used to describe the host system components and their behavior. The methodology architecture includes a diagnostic engine that utilizes a combination of heuristic knowledge to control the sequence of diagnostic reasoning. The methodology provides an integrated approach to development of diagnostic system requirements that is more rigorous than standard systems engineering techniques. The advantages of using this methodology during various life cycle phases of the host systems (e.g., National Aerospace Plane (NASP)) include: the capability to analyze diagnostic instrumentation requirements during the host system design phase, a ready software architecture for implementation of diagnostics in the host system, and the opportunity to analyze instrumentation for failure coverage in safety critical host system operations.
Delfiner, Matthew S; Martinez, Luis R; Pavia, Charles S
2016-01-01
Laboratory diagnostic tests have an essential role in patient care, and the increasing number of medical and health professions schools focusing on teaching laboratory medicine to pre-clinical students reflects this importance. However, data validating the pedagogical methods that best influence students' comprehension and interpretation of diagnostic tests have not been well described. The Gram stain is a simple yet significant and frequently used diagnostic test in the clinical setting that helps classify bacteria into two major groups, Gram positive and negative, based on their cell wall structure. We used this technique to assess which educational strategies may improve students' learning and competency in medical diagnostic techniques. Hence, in this randomized controlled study, we compared the effectiveness of several educational strategies (e.g. workshop, discussion, or lecture) in first year medical students' competency in comprehension and interpretation of the Gram stain procedure. We demonstrated that a hands-on practical workshop significantly enhances students' competency in memorization and overall comprehension of the technique. Interestingly, most students irrespective of their cohort showed difficulty in answering Gram stain-related analytical questions, suggesting that more emphasis should be allocated by the instructors to clearly explain the interpretation of the diagnostic test results to students in medical and health professional schools. This proof of principle study highlights the need of practical experiences on laboratory medical techniques during pre-clinical training to facilitate future medical doctors' and healthcare professionals' basic understanding and competency in diagnostic testing for better patient care.
Multi-method automated diagnostics of rotating machines
NASA Astrophysics Data System (ADS)
Kostyukov, A. V.; Boychenko, S. N.; Shchelkanov, A. V.; Burda, E. A.
2017-08-01
The automated machinery diagnostics and monitoring systems utilized within the petrochemical plants are an integral part of the measures taken to ensure safety and, as a consequence, the efficiency of these industrial facilities. Such systems are often limited in their functionality due to the specifics of the diagnostic techniques adopted. As the diagnostic techniques applied in each system are limited, and machinery defects can have different physical nature, it becomes necessary to combine several diagnostics and monitoring systems to control various machinery components. Such an approach is inconvenient, since it requires additional measures to bring the diagnostic results in a single view of the technical condition of production assets. In this case, we mean by a production facility a bonded complex of a process unit, a drive, a power source and lines. A failure of any of these components will cause an outage of the production asset, which is unacceptable. The purpose of the study is to test a combined use of vibration diagnostics and partial discharge techniques within the diagnostic systems of enterprises for automated control of the technical condition of rotating machinery during maintenance and at production facilities. The described solutions allow you to control the condition of mechanical and electrical components of rotating machines. It is shown that the functionality of the diagnostics systems can be expanded with minimal changes in technological chains of repair and operation of rotating machinery. Automation of such systems reduces the influence of the human factor on the quality of repair and diagnostics of the machinery.
Schlieren, Phase-Contrast, and Spectroscopy Diagnostics for the LBNL HIF Plasma Channel Experiment
NASA Astrophysics Data System (ADS)
Ponce, D. M.; Niemann, C.; Fessenden, T. J.; Leemans, W.; Vandersloot, K.; Dahlbacka, G.; Yu, S. S.; Sharp, W. M.; Tauschwitz, A.
1999-11-01
The LBNL Plasma Channel experiment has demonstrated stable 42-cm Z-pinch discharge plasma channels with peak currents in excess of 50 kA for a 7 torr nitrogen, 30 kV discharge. These channels offer the possibility of transporting heavy-ion beams for inertial fusion. We postulate that the stability of these channels resides in the existance of a neutral-gas density depresion created by a pre-pulse discharge before the main capacitor bank discharge is created. Here, we present the results and experimental diagnostics setup used for the study of the pre-pulse and main bank channels. Observation of both the plasma and neutral gas dynamics is achieved. Schlieren, Zernike's phase-contrast, and spectroscopic techniques are used. Preliminary Schlieren results show a gas shockwave moving radially at a rate of ≈ 10^6 mm/sec as a result of the fast and localized deposited energy during the evolution of the pre-pulse channel. This data will be used to validate simulation codes (BUCKY and CYCLOPS).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torrisi, Giuseppe; University Mediterranea of Reggio Calabria, Reggio Calabria; Mascali, David
2016-02-15
The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chambermore » radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.« less
A Formidable Foe is Sabotaging Your Results: What You Should Know about Biofilms and Wound Healing
Barker, Jenny C; Khansa, Ibrahim; Gordillo, Gayle M
2017-01-01
Learning Objectives After reading this article, the participant should be able to: 1. Describe biofilm pathogenesis as it relates to problem wounds, 2. Understand the pre-clinical and clinical evidence implicating biofilm in problem wounds, 3. Explain the diagnostic and treatment challenges that biofilms create for problem wounds, 4. Demonstrate a basic understanding of emerging strategies aimed at counteracting these processes. Summary Biofilm represents a protected mode of growth for bacteria, allowing them to evade standard diagnostic techniques and avoid eradication by standard therapies. Though only recently discovered, biofilm has existed for millennia and complicates nearly every aspect of medicine. Biofilm impacts wound healing by allowing bacteria to evade immune responses, prolonging inflammation and disabling skin barrier function. It is important to understand why problem wounds persist despite state-of-the-art treatment, why they are difficult to accurately diagnose, and why they recur. The aim of this article is to focus on current gaps in knowledge related to problem wounds, specifically, biofilm infection. PMID:28445380
NASA Astrophysics Data System (ADS)
Parente, M.; Bishop, J. L.
2008-12-01
Mapping of Mars by MRO has revealed the presence of numerous small phyllosilicate outcrops. These are typically identified in CRISM images using "summary products" (Pelkey, 2007) that consist of band ratios, depths and spectral slopes around diagnostic wavelengths. The summary products are designed to capture spectral features related to both surface mineralogy and atmospheric gases and aerosols. Such products, as an analysis tool to characterize composition as well as a targeting tool to identify areas of mineralogical interest, have been successful in capturing the known diversity of the Martian surface, and in highlighting locations with strong spectral signatures. Here we present alternative mineral mapping technique that 1) aims to increase the robustness of mineral detections with respect to the specific CRISM artifacts, 2) takes advantage of the spatial context of each pixel and 3) develops new parameters for the discrimination of species in the phyllosilicates family. We include spatial context by evaluating spectral shapes, band depths and spectral slopes for the current pixel based on its spatial neighbors within the same geological unit. Furthermore, the parameters are based on estimates that are more robust to CRISM speckling noise that might alter the parameters and potentially the mineral interpretation. As an effort to distinguish between phyllosilicates species, we are augmenting the suite of existent parameters with a set of mineral parameters that involve the position, number and shapes of diagnostic phyllosilicate absorptions. We are comparing the effectiveness of this new approach to the summary product procedure. The study shows that homogeneous mineral maps and diagnostic spectral identifications are possible as a result of the application of such new parameters. We applied the technique to the discrimination of kaolinite in Mawrth Vallis. The experiments show several small kaolinite outcrops dispersed within the more extensive Al-rich phyllosilicates in regions around the MSL landing sites. Another test was the discrimination of montmorillonite and nontronite in Mawrth Vallis that can be successfully accomplished by band depths summary products near 2.2 and 2.3 μm. The new technique produces improved maps with lower noise levels and lower percentage of false detections.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murokh, A.; Pellegrini, C.; Rosenzweig, J.
The VISA (Visible to Infrared SASE Amplifier) project is designed to be a SASE-FEL driven to saturation in the sub-micron wavelength region. Its goal is to test various aspects of the existing theory of Self-Amplified Spontaneous Emission, as well as numerical codes. Measurements include: angular and spectral distribution of the FEL light at the exit and inside of the undulator; electron beam micro-bunching using CTR; single-shot time resolved measurements of the pulse profile, using auto-correlation technique and FROG algorithm. The diagnostics are designed to provide maximum information on the physics of the SASE-FEL process, to ensure a close comparison ofmore » the experimental results with theory and simulations.« less
Fuel-injector/air-swirl characterization
NASA Technical Reports Server (NTRS)
Mcvey, J. B.; Kennedy, J. B.; Bennett, J. C.
1985-01-01
The objectives of this program are to establish an experimental data base documenting the behavior of gas turbine engine fuel injector sprays as the spray interacts with the swirling gas flow existing in the combustor dome, and to conduct an assessment of the validity of current analytical techniques for predicting fuel spray behavior. Emphasis is placed on the acquisition of data using injector/swirler components which closely resemble components currently in use in advanced aircraft gas turbine engines, conducting tests under conditions that closely simulate or closely approximate those developed in actual combustors, and conducting a well-controlled experimental effort which will comprise using a combination of low-risk experiments and experiments requiring the use of state-of-the-art diagnostic instrumentation. Analysis of the data is to be conducted using an existing, TEACH-type code which employs a stochastic analysis of the motion of the dispersed phase in the turbulent continuum flow field.
Multi-Tasking Non-Destructive Laser Technology in Conservation Diagnostic Procedures
NASA Astrophysics Data System (ADS)
Tornari, V.; Tsiranidou, E.; Orphanos, Y.; Falldorf, C.; Klattenhof, R.; Esposito, E.; Agnani, A.; Dabu, R.; Stratan, A.; Anastassopoulos, A.; Schipper, D.; Hasperhoven, J.; Stefanaggi, M.; Bonnici, H.; Ursu, D.
Laser metrology provides techniques that have been successfully applied in industrial structural diagnostic fields but have not yet been refined and optimised for the special investigative requirements found in cultural heritage applications. A major impediment is the partial applicability of various optical coherent techniques, each one narrowing its use down to a specific application. This characteristic is not well suited for a field that encounters a great variety of diagnostic problems ranging from movable, multiple-composition museum objects, to immovable multi-layered wall paintings, statues and wood carvings, to monumental constructions and outdoor cultural heritage sites. Various diagnostic techniques have been suggested and are uniquely suited for each of the mentioned problems but it is this fragmented suitability that obstructs the technology transfer. Since optical coherent techniques for metrology are based on fundamental principles and take advantage of similar procedures for generation of informative signals for data collection, then the imposed limits elevate our aim to identify complementary capabilities to accomplish the needed functionality.
Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.
Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes
2017-03-01
Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.
MEMS-based power generation techniques for implantable biosensing applications.
Lueke, Jonathan; Moussa, Walied A
2011-01-01
Implantable biosensing is attractive for both medical monitoring and diagnostic applications. It is possible to monitor phenomena such as physical loads on joints or implants, vital signs, or osseointegration in vivo and in real time. Microelectromechanical (MEMS)-based generation techniques can allow for the autonomous operation of implantable biosensors by generating electrical power to replace or supplement existing battery-based power systems. By supplementing existing battery-based power systems for implantable biosensors, the operational lifetime of the sensor is increased. In addition, the potential for a greater amount of available power allows additional components to be added to the biosensing module, such as computational and wireless and components, improving functionality and performance of the biosensor. Photovoltaic, thermovoltaic, micro fuel cell, electrostatic, electromagnetic, and piezoelectric based generation schemes are evaluated in this paper for applicability for implantable biosensing. MEMS-based generation techniques that harvest ambient energy, such as vibration, are much better suited for implantable biosensing applications than fuel-based approaches, producing up to milliwatts of electrical power. High power density MEMS-based approaches, such as piezoelectric and electromagnetic schemes, allow for supplemental and replacement power schemes for biosensing applications to improve device capabilities and performance. In addition, this may allow for the biosensor to be further miniaturized, reducing the need for relatively large batteries with respect to device size. This would cause the implanted biosensor to be less invasive, increasing the quality of care received by the patient.
Chung, Hyunji; Iorga, Michaela; Voas, Jeffrey; Lee, Sangjin
2017-01-01
Security diagnostics expose vulnerabilities and privacy threats that exist in commercial Intelligent Virtual Assistants (IVA) – diagnostics offer the possibility of securer IVA ecosystems. PMID:29213147
New Diagnostic Aides for Melanoma
Ferris, Laura K.; Harris, Ryan J.
2012-01-01
Synopsis Detection of melanoma at an early stage is crucial to improving survival rates in melanoma. Accurate diagnosis by current techniques including dermatoscopy remains difficult, and new tools are needed to improve our diagnostic abilities. This article discusses recent advances in diagnostic techniques including confocal scanning laser microscopy, MelaFind, Siascopy, noninvasive genomic detection, as well as other future possibilities to aid in diagnosing melanoma. Advantages and barriers to implementation of the various technologies are discussed as well. PMID:22800557
Longitudinal Beam Diagnostics for the ILC Injectors and Bunch Compressors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piot, Philippe; Bracke, Adam; Demir, Veysel
2010-12-01
We present a diagnostics suite and analyze techniques for setting up the longitudinal beam dynamics in ILC e⁻ injectors and e⁺ and e⁻ bunch compressors. Techniques to measure the first order moments and recover the first order longitudinal transfer map of the injector's intricate bunching scheme are presented. Coherent transition radiation diagnostics needed to measure and monitor the bunch length downstream of the ~5 GeV bunch compressor are investigated using a vector diffraction model.
NASA Astrophysics Data System (ADS)
Tsel'Sov, Iu. G.; Kondrat'ev, A. S.
1990-12-01
A method is developed for determining the temperature of an ionized gas on the basis of electron-density sounding. This technique is used to measure the cross-sectional temperature distribution of an axisymmetric ionized gas flow using microwave diagnostics.
Application of light and ultrasound for medical diagnostics and treatment
NASA Astrophysics Data System (ADS)
Esenaliev, Rinat O.
2002-07-01
We develop novel optical and ultrasound techniques for medical noninvasive diagnostics and treatment. In this review, we present our results on the development of: (1) optoacoustic technique for detection of small tumors; (2) optoacoustic monitoring of blood oxygenation; (3) optoacoustic monitoring during thermotherapy; (4) optical coherence tomography for monitoring of blood glucose concentration; and (5) laser- and ultrasound-based anti- cancer drug delivery technique. Motivation, experimental methods, results obtained in vitro and in vivo with the use of these techniques are presented.
Nasal hydropulsion: a novel tumor biopsy technique.
Ashbaugh, Elizabeth A; McKiernan, Brendan C; Miller, Carrie J; Powers, Barbara
2011-01-01
Intranasal tumors of dogs and cats pose a diagnostic and therapeutic challenge for small animal practitioners. Multiple nasal biopsy techniques have been described in the past. This report describes a simplified flushing technique to biopsy and debulk nasal tumors, which often also results in immediate clinical relief for the patient. Based on the results of this retrospective study, the authors recommend high-pressure saline hydropulsion as a minimally invasive diagnostic, and potentially therapeutic, technique for nasal tumors in dogs and cats.
Kielar, Maciej
2016-01-01
Aim The purpose of the study was to improve the ultrasonographic assessment of the anterior cruciate ligament by an inclusion of a dynamic element. The proposed functional modification aims to restore normal posterior cruciate ligament tension, which is associated with a visible change in the ligament shape. This method reduces the risk of an error resulting from subjectively assessing the shape of the posterior cruciate ligament. It should be also emphasized that the method combined with other ultrasound anterior cruciate ligament assessment techniques helps increase diagnostic accuracy. Methods Ultrasonography is used as an adjunctive technique in the diagnosis of anterior cruciate ligament injury. The paper presents a sonographic technique for the assessment of suspected anterior cruciate ligament insufficiency supplemented by the use of a dynamic examination. This technique can be recommended as an additional procedure in routine ultrasound diagnostics of anterior cruciate ligament injuries. Results Supplementing routine ultrasonography with the dynamic assessment of posterior cruciate ligament shape changes in patients with suspected anterior cruciate ligament injury reduces the risk of subjective errors and increases diagnostic accuracy. This is important especially in cases of minor anterior knee instability and bilateral anterior knee instability. Conclusions An assessment of changes in posterior cruciate ligament using a dynamic ultrasound examination effectively complements routine sonographic diagnostic techniques for anterior cruciate ligament insufficiency. PMID:27679732
A promising diagnostic method: Terahertz pulsed imaging and spectroscopy
Sun, Yiwen; Sy, Ming Yiu; Wang, Yi-Xiang J; Ahuja, Anil T; Zhang, Yuan-Ting; Pickwell-MacPherson, Emma
2011-01-01
The terahertz band lies between the microwave and infrared regions of the electromagnetic spectrum. This radiation has very low photon energy and thus it does not pose any ionization hazard for biological tissues. It is strongly attenuated by water and very sensitive to water content. Unique absorption spectra due to intermolecular vibrations in this region have been found in different biological materials. These unique features make terahertz imaging very attractive for medical applications in order to provide complimentary information to existing imaging techniques. There has been an increasing interest in terahertz imaging and spectroscopy of biologically related applications within the last few years and more and more terahertz spectra are being reported. This paper introduces terahertz technology and provides a short review of recent advances in terahertz imaging and spectroscopy techniques, and a number of applications such as molecular spectroscopy, tissue characterization and skin imaging are discussed. PMID:21512652
Current state of the art for enhancing urine biomarker discovery
Harpole, Michael; Davis, Justin; Espina, Virginia
2016-01-01
Urine is a highly desirable biospecimen for biomarker analysis because it can be collected recurrently by non-invasive techniques, in relatively large volumes. Urine contains cellular elements, biochemicals, and proteins derived from glomerular filtration of plasma, renal tubule excretion, and urogenital tract secretions that reflect, at a given time point, an individual's metabolic and pathophysiologic state. High-resolution mass spectrometry, coupled with state of the art fractionation systems are revealing the plethora of diagnostic/prognostic proteomic information existing within urinary exosomes, glycoproteins, and proteins. Affinity capture pre-processing techniques such as combinatorial peptide ligand libraries and biomarker harvesting hydrogel nanoparticles are enabling measurement/identification of previously undetectable urinary proteins. Future challenges in the urinary proteomics field include a) defining either single or multiple, universally applicable data normalization methods for comparing results within and between individual patients/data sets, and b) defining expected urinary protein levels in healthy individuals. PMID:27232439
Computer assisted diagnostic system in tumor radiography.
Faisal, Ahmed; Parveen, Sharmin; Badsha, Shahriar; Sarwar, Hasan; Reza, Ahmed Wasif
2013-06-01
An improved and efficient method is presented in this paper to achieve a better trade-off between noise removal and edge preservation, thereby detecting the tumor region of MRI brain images automatically. Compass operator has been used in the fourth order Partial Differential Equation (PDE) based denoising technique to preserve the anatomically significant information at the edges. A new morphological technique is also introduced for stripping skull region from the brain images, which consequently leading to the process of detecting tumor accurately. Finally, automatic seeded region growing segmentation based on an improved single seed point selection algorithm is applied to detect the tumor. The method is tested on publicly available MRI brain images and it gives an average PSNR (Peak Signal to Noise Ratio) of 36.49. The obtained results also show detection accuracy of 99.46%, which is a significant improvement than that of the existing results.
A novel murmur-based heart sound feature extraction technique using envelope-morphological analysis
NASA Astrophysics Data System (ADS)
Yao, Hao-Dong; Ma, Jia-Li; Fu, Bin-Bin; Wang, Hai-Yang; Dong, Ming-Chui
2015-07-01
Auscultation of heart sound (HS) signals serves as an important primary approach to diagnose cardiovascular diseases (CVDs) for centuries. Confronting the intrinsic drawbacks of traditional HS auscultation, computer-aided automatic HS auscultation based on feature extraction technique has witnessed explosive development. Yet, most existing HS feature extraction methods adopt acoustic or time-frequency features which exhibit poor relationship with diagnostic information, thus restricting the performance of further interpretation and analysis. Tackling such a bottleneck problem, this paper innovatively proposes a novel murmur-based HS feature extraction method since murmurs contain massive pathological information and are regarded as the first indications of pathological occurrences of heart valves. Adapting discrete wavelet transform (DWT) and Shannon envelope, the envelope-morphological characteristics of murmurs are obtained and three features are extracted accordingly. Validated by discriminating normal HS and 5 various abnormal HS signals with extracted features, the proposed method provides an attractive candidate in automatic HS auscultation.
Improving "lab-on-a-chip" techniques using biomedical nanotechnology: a review.
Gorjikhah, Fatemeh; Davaran, Soodabeh; Salehi, Roya; Bakhtiari, Mohsen; Hasanzadeh, Arash; Panahi, Yunes; Emamverdy, Masumeh; Akbarzadeh, Abolfazl
2016-11-01
Nanotechnology and its applications in biomedical sciences principally in molecular nanodiagnostics are known as nanomolecular diagnostics, which provides new options for clinical nanodiagnostic techniques. Molecular nanodiagnostics are a critical role in the development of personalized medicine, which features point-of care performance of diagnostic procedure. This can to check patients at point-of-care facilities or in remote or resource-poor locations, therefore reducing checking time from days to minutes. In this review, applications of nanotechnology suited to biomedicine are discussed in two main class: biomedical applications for use inside (such as drugs, diagnostic techniques, prostheses, and implants) and outside the body (such as "lab-on-a-chip" techniques). A lab-on-a-chip (LOC) is a tool that incorporates numerous laboratory tasks onto a small device, usually only millimeters or centimeters in size. Finally, are discussed the applications of biomedical nanotechnology in improving "lab-on-a-chip" techniques.
Infrared Imaging Tools for Diagnostic Applications in Dermatology.
Gurjarpadhye, Abhijit Achyut; Parekh, Mansi Bharat; Dubnika, Arita; Rajadas, Jayakumar; Inayathullah, Mohammed
Infrared (IR) imaging is a collection of non-invasive imaging techniques that utilize the IR domain of the electromagnetic spectrum for tissue assessment. A subset of these techniques construct images using back-reflected light, while other techniques rely on detection of IR radiation emitted by the tissue as a result of its temperature. Modern IR detectors sense thermal emissions and produce a heat map of surface temperature distribution in tissues. Thus, the IR spectrum offers a variety of imaging applications particularly useful in clinical diagnostic area, ranging from high-resolution, depth-resolved visualization of tissue to temperature variation assessment. These techniques have been helpful in the diagnosis of many medical conditions including skin/breast cancer, arthritis, allergy, burns, and others. In this review, we discuss current roles of IR-imaging techniques for diagnostic applications in dermatology with an emphasis on skin cancer, allergies, blisters, burns and wounds.
Zhang, J-F; Xu, J; Bergquist, R; Yu, L-L; Yan, X-L; Zhu, H-Q; Wen, L-Y
2016-01-01
Schistosomiasis, caused by Schistosoma japonicum infection to human, has a documented history of more than 2100years in The People's Republic of China. In spite of great progress in controlling the disease, it is still one of the most serious parasitic diseases in the country. The study and use of diagnostic techniques play an important role in the targeting of chemotherapy that has been continuously applied in the national schistosomiasis control programme for several decades. This paper reviews the development and application of parasitological, immunodiagnostic and molecular diagnostic technology for S. japonicum in The People's Republic of China with a brief mention of diagnostic imagery, such as ultrasound and radiology. When analysing the efficacy and performance characteristics of the main diagnostic techniques in current use, it becomes apparent that approaches that worked well in the past are less suitable now as successful control has shifted the endemic situation towards control and interruption of transmission. The conclusion is that a mutable approach must be adopted choosing the most appropriate diagnostic technique for each control stage (and area), thus modifying the methodology according to the prevailing diagnostic needs in terms of sensitivity and specificity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements.
Wang, Zhennan; Wang, Chuji
2013-09-01
Since the ancient discovery of the 'sweet odor' in human breath gas, pursuits of the breath analysis-based disease diagnostics have never stopped. Actually, the 'smell' of the breath, as one of three key disease diagnostic techniques, has been used in Eastern-Medicine for more than three thousand years. With advancement of measuring technologies in sensitivity and selectivity, more specific breath gas species have been identified and established as a biomarker of a particular disease. Acetone is one of the breath gases and its concentration in exhaled breath can now be determined with high accuracy using various techniques and methods. With the worldwide prevalence of diabetes that is typically diagnosed through blood testing, human desire to achieve non-blood based diabetic diagnostics and monitoring has never been quenched. Questions, such as is breath acetone a biomarker of diabetes and how is the breath acetone related to the blood glucose (BG) level (the golden criterion currently used in clinic for diabetes diagnostic, monitoring, and management), remain to be answered. A majority of current research efforts in breath acetone measurements and its technology developments focus on addressing the first question. The effort to tackle the second question has begun recently. The earliest breath acetone measurement in clearly defined diabetic patients was reported more than 60 years ago. For more than a half-century, as reviewed in this paper, there have been more than 41 independent studies of breath acetone using various techniques and methods, and more than 3211 human subjects, including 1581 healthy people, 242 Type 1 diabetic patients, 384 Type 2 diabetic patients, 174 unspecified diabetic patients, and 830 non-diabetic patients or healthy subjects who are under various physiological conditions, have been used in the studies. The results of the breath acetone measurements collected in this review support that many conditions might cause changes to breath acetone concentrations; however, the results from the six independent studies using clearly-defined Type 1 and Type 2 diabetic patients unanimously support that an elevated mean breath acetone concentration exists in Type 1 diabetes. Note that there is some overlap between the ranges of breath acetone concentration in individual T1D patients and healthy subjects; this reminds one to be careful when using an acetone breath test on T1D diagnostics. Comparatively, it is too early to draw a general conclusion on the relationship between a breath acetone level and a BG level from the very limited data in the literature.
Laser Diagnostics for combustion temperature and species measurements
NASA Technical Reports Server (NTRS)
Eckbreth, Alan C.
1988-01-01
Laser optical diagnostic techniques for the measurement of combustion gaseous-phase temperatures and, or species concentrations are discussed. The techniques fall into two classes: incoherent (Rayleigh scattering, spontaneous Raman scattering, laser induced fluorescence spectroscopy) and coherent (coherent anti-Stokes Raman spectroscopy). The advantages, disadvantages and applicability of each method are outlined.
Rocket engine diagnostics using qualitative modeling techniques
NASA Technical Reports Server (NTRS)
Binder, Michael; Maul, William; Meyer, Claudia; Sovie, Amy
1992-01-01
Researchers at NASA Lewis Research Center are presently developing qualitative modeling techniques for automated rocket engine diagnostics. A qualitative model of a turbopump interpropellant seal system has been created. The qualitative model describes the effects of seal failures on the system steady-state behavior. This model is able to diagnose the failure of particular seals in the system based on anomalous temperature and pressure values. The anomalous values input to the qualitative model are generated using numerical simulations. Diagnostic test cases include both single and multiple seal failures.
Rocket engine diagnostics using qualitative modeling techniques
NASA Technical Reports Server (NTRS)
Binder, Michael; Maul, William; Meyer, Claudia; Sovie, Amy
1992-01-01
Researchers at NASA Lewis Research Center are presently developing qualitative modeling techniques for automated rocket engine diagnostics. A qualitative model of a turbopump interpropellant seal system was created. The qualitative model describes the effects of seal failures on the system steady state behavior. This model is able to diagnose the failure of particular seals in the system based on anomalous temperature and pressure values. The anomalous values input to the qualitative model are generated using numerical simulations. Diagnostic test cases include both single and multiple seal failures.
NASA Technical Reports Server (NTRS)
Powers, E. J.; Kim, Y. C.; Hong, J. Y.; Roth, J. R.; Krawczonek, W. M.
1978-01-01
A diagnostic, based on fast Fourier-transform spectral analysis techniques, that provides experimental insight into the relationship between the experimentally observable spectral characteristics of the fluctuations and the fluctuation-induced plasma transport is described. The model upon which the diagnostic technique is based and its experimental implementation is discussed. Some characteristic results obtained during the course of an experimental study of fluctuation-induced transport in the electric field dominated NASA Lewis bumpy torus plasma are presented.
NASA Astrophysics Data System (ADS)
Hong, Liu; Qu, Yongzhi; Dhupia, Jaspreet Singh; Sheng, Shuangwen; Tan, Yuegang; Zhou, Zude
2017-09-01
The localized failures of gears introduce cyclic-transient impulses in the measured gearbox vibration signals. These impulses are usually identified from the sidebands around gear-mesh harmonics through the spectral analysis of cyclo-stationary signals. However, in practice, several high-powered applications of gearboxes like wind turbines are intrinsically characterized by nonstationary processes that blur the measured vibration spectra of a gearbox and deteriorate the efficacy of spectral diagnostic methods. Although order-tracking techniques have been proposed to improve the performance of spectral diagnosis for nonstationary signals measured in such applications, the required hardware for the measurement of rotational speed of these machines is often unavailable in industrial settings. Moreover, existing tacho-less order-tracking approaches are usually limited by the high time-frequency resolution requirement, which is a prerequisite for the precise estimation of the instantaneous frequency. To address such issues, a novel fault-signature enhancement algorithm is proposed that can alleviate the spectral smearing without the need of rotational speed measurement. This proposed tacho-less diagnostic technique resamples the measured acceleration signal of the gearbox based on the optimal warping path evaluated from the fast dynamic time-warping algorithm, which aligns a filtered shaft rotational harmonic signal with respect to a reference signal assuming a constant shaft rotational speed estimated from the approximation of operational speed. The effectiveness of this method is validated using both simulated signals from a fixed-axis gear pair under nonstationary conditions and experimental measurements from a 750-kW planetary wind turbine gearbox on a dynamometer test rig. The results demonstrate that the proposed algorithm can identify fault information from typical gearbox vibration measurements carried out in a resource-constrained industrial environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Liu; Qu, Yongzhi; Dhupia, Jaspreet Singh
The localized failures of gears introduce cyclic-transient impulses in the measured gearbox vibration signals. These impulses are usually identified from the sidebands around gear-mesh harmonics through the spectral analysis of cyclo-stationary signals. However, in practice, several high-powered applications of gearboxes like wind turbines are intrinsically characterized by nonstationary processes that blur the measured vibration spectra of a gearbox and deteriorate the efficacy of spectral diagnostic methods. Although order-tracking techniques have been proposed to improve the performance of spectral diagnosis for nonstationary signals measured in such applications, the required hardware for the measurement of rotational speed of these machines is oftenmore » unavailable in industrial settings. Moreover, existing tacho-less order-tracking approaches are usually limited by the high time-frequency resolution requirement, which is a prerequisite for the precise estimation of the instantaneous frequency. To address such issues, a novel fault-signature enhancement algorithm is proposed that can alleviate the spectral smearing without the need of rotational speed measurement. This proposed tacho-less diagnostic technique resamples the measured acceleration signal of the gearbox based on the optimal warping path evaluated from the fast dynamic time-warping algorithm, which aligns a filtered shaft rotational harmonic signal with respect to a reference signal assuming a constant shaft rotational speed estimated from the approximation of operational speed. The effectiveness of this method is validated using both simulated signals from a fixed-axis gear pair under nonstationary conditions and experimental measurements from a 750-kW planetary wind turbine gearbox on a dynamometer test rig. Lastly, the results demonstrate that the proposed algorithm can identify fault information from typical gearbox vibration measurements carried out in a resource-constrained industrial environment.« less
Hong, Liu; Qu, Yongzhi; Dhupia, Jaspreet Singh; ...
2017-02-27
The localized failures of gears introduce cyclic-transient impulses in the measured gearbox vibration signals. These impulses are usually identified from the sidebands around gear-mesh harmonics through the spectral analysis of cyclo-stationary signals. However, in practice, several high-powered applications of gearboxes like wind turbines are intrinsically characterized by nonstationary processes that blur the measured vibration spectra of a gearbox and deteriorate the efficacy of spectral diagnostic methods. Although order-tracking techniques have been proposed to improve the performance of spectral diagnosis for nonstationary signals measured in such applications, the required hardware for the measurement of rotational speed of these machines is oftenmore » unavailable in industrial settings. Moreover, existing tacho-less order-tracking approaches are usually limited by the high time-frequency resolution requirement, which is a prerequisite for the precise estimation of the instantaneous frequency. To address such issues, a novel fault-signature enhancement algorithm is proposed that can alleviate the spectral smearing without the need of rotational speed measurement. This proposed tacho-less diagnostic technique resamples the measured acceleration signal of the gearbox based on the optimal warping path evaluated from the fast dynamic time-warping algorithm, which aligns a filtered shaft rotational harmonic signal with respect to a reference signal assuming a constant shaft rotational speed estimated from the approximation of operational speed. The effectiveness of this method is validated using both simulated signals from a fixed-axis gear pair under nonstationary conditions and experimental measurements from a 750-kW planetary wind turbine gearbox on a dynamometer test rig. Lastly, the results demonstrate that the proposed algorithm can identify fault information from typical gearbox vibration measurements carried out in a resource-constrained industrial environment.« less
Quality control in mutation analysis: the European Molecular Genetics Quality Network (EMQN).
Müller, C R
2001-08-01
The demand for clinical molecular genetics testing has steadily grown since its introduction in the 1980s. In order to reach and maintain the agreed quality standards of laboratory medicine, the same internal and external quality assurance (IQA/EQA) criteria have to be applied as for "conventional" clinical chemistry or pathology. In 1996 the European Molecular Genetics Quality Network (EMQN) was established in order to spread QA standards across Europe and to harmonise the existing national activities. EMQN is operated by a central co-ordinator and 17 national partners from 15 EU countries; since 1998 it is being funded by the EU commission for a 3-year period. EMQN promotes QA by two tools: by providing disease-specific best practice meetings (BPM) and EQA schemes. A typical BPM is focussed on one disease or group of related disorders. International experts report on the latest news of gene characterisation and function and the state-of-the-art techniques for mutation detection. Disease-specific EQA schemes are provided by experts in the field. DNA samples are sent out together with mock clinical referrals and a diagnostic question is asked. Written reports must be returned which are marked for genotyping and interpretation. So far, three BPMs have been held and six EQA schemes are in operation at various stages. Although mutation types and diagnostic techniques varied considerably between schemes, the overall technical performance showed a high diagnostic standard. Nevertheless, serious genotyping errors have been occurred in some schemes which underline the necessity of quality assurance efforts. The European Molecular Genetics Quality Network provides a necessary platform for the internal and external quality assurance of molecular genetic testing.
AST Combustion Workshop: Diagnostics Working Group Report
NASA Technical Reports Server (NTRS)
Locke, Randy J.; Hicks, Yolanda R.; Hanson, Ronald K.
1996-01-01
A workshop was convened under NASA's Advanced Subsonics Technologies (AST) Program. Many of the principal combustion diagnosticians from industry, academia, and government laboratories were assembled in the Diagnostics/Testing Subsection of this workshop to discuss the requirements and obstacles to the successful implementation of advanced diagnostic techniques to the test environment of the proposed AST combustor. The participants, who represented the major relevant areas of advanced diagnostic methods currently applied to combustion and related fields, first established the anticipated AST combustor flowfield conditions. Critical flow parameters were then examined and prioritized as to their importance to combustor/fuel injector design and manufacture, environmental concerns, and computational interests. Diagnostic techniques were then evaluated in terms of current status, merits and obstacles for each flow parameter. All evaluations are presented in tabular form and recommendations are made on the best-suited diagnostic method to implement for each flow parameter in order of applicability and intrinsic value.
Current audiological diagnostics
Hoth, Sebastian; Baljić, Izet
2017-01-01
Today’s audiological functional diagnostics is based on a variety of hearing tests, whose large number takes account of the variety of malfunctions of a complex sensory organ system and the necessity to examine it in a differentiated manner and at any age of life. The objective is to identify nature and origin of the hearing loss and to quantify its extent as far as necessary to dispose of the information needed to initiate the adequate medical (conservative or operational) treatment or the provision with technical hearing aids or prostheses. Moreover, audiometry provides the basis for the assessment of impairment and handicap as well as for the calculation of the degree of disability. In the present overview, the current state of the method inventory available for practical use is described, starting from basic diagnostics over to complex special techniques. The presentation is systematically grouped in subjective procedures, based on psychoacoustic exploration, and objective methods, based on physical measurements: preliminary hearing tests, pure tone threshold, suprathreshold processing of sound intensity, directional hearing, speech understanding in quiet and in noise, dichotic hearing, tympanogram, acoustic reflex, otoacoustic emissions and auditory evoked potentials. Apart from a few still existing gaps, this method inventory covers the whole spectrum of all clinically relevant functional deficits of the auditory system. PMID:29279727
Fault Diagnostics for Turbo-Shaft Engine Sensors Based on a Simplified On-Board Model
Lu, Feng; Huang, Jinquan; Xing, Yaodong
2012-01-01
Combining a simplified on-board turbo-shaft model with sensor fault diagnostic logic, a model-based sensor fault diagnosis method is proposed. The existing fault diagnosis method for turbo-shaft engine key sensors is mainly based on a double redundancies technique, and this can't be satisfied in some occasions as lack of judgment. The simplified on-board model provides the analytical third channel against which the dual channel measurements are compared, while the hardware redundancy will increase the structure complexity and weight. The simplified turbo-shaft model contains the gas generator model and the power turbine model with loads, this is built up via dynamic parameters method. Sensor fault detection, diagnosis (FDD) logic is designed, and two types of sensor failures, such as the step faults and the drift faults, are simulated. When the discrepancy among the triplex channels exceeds a tolerance level, the fault diagnosis logic determines the cause of the difference. Through this approach, the sensor fault diagnosis system achieves the objectives of anomaly detection, sensor fault diagnosis and redundancy recovery. Finally, experiments on this method are carried out on a turbo-shaft engine, and two types of faults under different channel combinations are presented. The experimental results show that the proposed method for sensor fault diagnostics is efficient. PMID:23112645
Fault diagnostics for turbo-shaft engine sensors based on a simplified on-board model.
Lu, Feng; Huang, Jinquan; Xing, Yaodong
2012-01-01
Combining a simplified on-board turbo-shaft model with sensor fault diagnostic logic, a model-based sensor fault diagnosis method is proposed. The existing fault diagnosis method for turbo-shaft engine key sensors is mainly based on a double redundancies technique, and this can't be satisfied in some occasions as lack of judgment. The simplified on-board model provides the analytical third channel against which the dual channel measurements are compared, while the hardware redundancy will increase the structure complexity and weight. The simplified turbo-shaft model contains the gas generator model and the power turbine model with loads, this is built up via dynamic parameters method. Sensor fault detection, diagnosis (FDD) logic is designed, and two types of sensor failures, such as the step faults and the drift faults, are simulated. When the discrepancy among the triplex channels exceeds a tolerance level, the fault diagnosis logic determines the cause of the difference. Through this approach, the sensor fault diagnosis system achieves the objectives of anomaly detection, sensor fault diagnosis and redundancy recovery. Finally, experiments on this method are carried out on a turbo-shaft engine, and two types of faults under different channel combinations are presented. The experimental results show that the proposed method for sensor fault diagnostics is efficient.
Huddy, Jeremy R; Ni, Melody Z; Markar, Sheraz R; Hanna, George B
2015-01-01
Point-of-care (POC) tests enable rapid results and are well established in medical practice. Recent advances in analytical techniques have led to a new generation of POC devices that will alter gastrointestinal diagnostic pathways. This review aims to identify current and new technologies for the POC diagnosis of gastrointestinal cancer. A structured search of the Embase and Medline databases was performed. Papers reporting diagnostic tests for gastrointestinal cancer available as a POC device or containing a description of feasibility for POC application were included. Studies recovered were heterogeneous and therefore results are presented as a narrative review. Six diagnostic methods were identified (fecal occult blood, fecal proteins, volatile organic compounds, pyruvate kinase isoenzyme type M2, tumour markers and DNA analysis). Fecal occult blood testing has a reported sensitivity of 66%-85% and specificity greater than 95%. The others are at a range of development and clinical application. POC devices have a proven role in the diagnosis of gastrointestinal cancer. Barriers to their implementation exist and the transition from experimental to clinical medicine is currently slow. New technologies demonstrate potential to provide accurate POC tests and an ability to diagnose gastrointestinal cancer at an early stage with improved clinical outcome and survival. PMID:25892860
Huddy, Jeremy R; Ni, Melody Z; Markar, Sheraz R; Hanna, George B
2015-04-14
Point-of-care (POC) tests enable rapid results and are well established in medical practice. Recent advances in analytical techniques have led to a new generation of POC devices that will alter gastrointestinal diagnostic pathways. This review aims to identify current and new technologies for the POC diagnosis of gastrointestinal cancer. A structured search of the Embase and Medline databases was performed. Papers reporting diagnostic tests for gastrointestinal cancer available as a POC device or containing a description of feasibility for POC application were included. Studies recovered were heterogeneous and therefore results are presented as a narrative review. Six diagnostic methods were identified (fecal occult blood, fecal proteins, volatile organic compounds, pyruvate kinase isoenzyme type M2, tumour markers and DNA analysis). Fecal occult blood testing has a reported sensitivity of 66%-85% and specificity greater than 95%. The others are at a range of development and clinical application. POC devices have a proven role in the diagnosis of gastrointestinal cancer. Barriers to their implementation exist and the transition from experimental to clinical medicine is currently slow. New technologies demonstrate potential to provide accurate POC tests and an ability to diagnose gastrointestinal cancer at an early stage with improved clinical outcome and survival.
Carter, Cristina; Akar-Ghibril, Nicole; Sestokas, Jeff; Dixon, Gabrina; Bradford, Wilhelmina; Ottolini, Mary
2018-03-01
Oral case presentations provide an opportunity for trainees to communicate diagnostic reasoning at the bedside. However, few tools exist to enable faculty to provide effective feedback. We developed a tool to assess diagnostic reasoning and communication during oral case presentations. Published by Elsevier Inc.
He, Xiaoning; Holtorf, Anke-Peggy; Rinde, Harald; Xie, Shuangshuang; Shen, Wen; Hou, Jiancun; Li, Xuehua; Li, Ziping; Lai, Jiaming; Wang, Yuting; Zhang, Lin; Wang, Jian; Li, Xuesong; Ma, Kuansheng; Ye, Feng; Ouyang, Han; Zhao, Hong
2018-01-01
Limited data exists in China on the comparative cost of gadolinium ethoxybenzyl diethylenetriamine magnetic resonance imaging (Gd-EOB-DTPA-MRI) with other imaging techniques. This study compared the total cost of Gd-EOB-DTPA-MRI with multidetector computed tomography (MDCT) and extracellular contrast media–enhanced MRI (ECCM-MRI) as initial imaging procedures in patients with suspected hepatocellular carcinoma (HCC). We developed a decision-tree model on the basis of the Chinese clinical guidelines for HCC, which was validated by clinical experts from China. The model compared the diagnostic accuracy and costs of alternative initial imaging procedures. Compared with MDCT and ECCM-MRI, Gd-EOB-DTPA-MRI imaging was associated with higher rates of diagnostic accuracy, i.e. higher proportions of true positives (TP) and true negatives (TN) with lower false positives (FP). Total diagnosis and treatment cost per patient after the initial Gd-EOB-DTPA-MRI evaluation was similar to MDCT (¥30,360 vs. ¥30,803) and lower than that reported with ECCM-MRI (¥30,360 vs. ¥31,465). Lower treatment cost after initial Gd-EOB-DTPA-MRI was driven by reduced utilization of confirmatory diagnostic procedures and unnecessary treatments. The findings reported that Gd-EOB-DTPA-MRI offered higher diagnostic accuracy compared with MDCT and ECCM-MRI at a comparable cost, which indicates Gd-EOB-DTPA-MRI could be the preferred initial imaging procedure for the diagnosis of HCC in China. PMID:29324837
First results with a lab-on-a-chip system for a fast Phytophthora diagnosis.
Sonja Horatzek; Stephan König; Stefan Wagner; Sabine Werres; Lydia Schwenkbier; Karina Weber; Jörg. Weber
2013-01-01
For Phytophthora spp. that are quarantine or regulated organisms, highly specific and sensitive diagnostic tools are recommended for surveys and monitoring. Furthermore, these diagnostic techniques should give results within a short time and should be not be too expensive. The techniques currently used for routine diagnosis of ...
Rifle Marksmanship Diagnostic and Training Guide
2011-05-01
there any techniques you use to help prepare Soldiers to transition to firing with aiming lights (PEQ-2 or PAQ -4) and night vision goggles (ARM 1)? If...firing skills with the PAQ -4? A‐5 15. Are there any other diagnostic techniques you use that we haven’t discussed? a. Think back on your
Frakking, Thuy T; Chang, Anne B; O'Grady, Kerry-Ann F; Walker-Smith, Katie; Weir, Kelly A
2013-11-07
Oropharyngeal aspiration (OPA) can lead to recurrent respiratory illnesses and chronic lung disease in children. Current clinical feeding evaluations performed by speech pathologists have poor reliability in detecting OPA when compared to radiological procedures such as the modified barium swallow (MBS). Improved ability to diagnose OPA accurately via clinical evaluation potentially reduces reliance on expensive, less readily available radiological procedures. Our study investigates the utility of adding cervical auscultation (CA), a technique of listening to swallowing sounds, in improving the diagnostic accuracy of a clinical evaluation for the detection of OPA. We plan an open, unblinded, randomised controlled trial at a paediatric tertiary teaching hospital. Two hundred and sixteen children fulfilling the inclusion criteria will be randomised to one of the two clinical assessment techniques for the clinical detection of OPA: (1) clinical feeding evaluation only (CFE) group or (2) clinical feeding evaluation with cervical auscultation (CFE + CA) group. All children will then undergo an MBS to determine radiologically assessed OPA. The primary outcome is the presence or absence of OPA, as determined on MBS using the Penetration-Aspiration Scale. Our main objective is to determine the sensitivity, specificity, negative and positive predictive values of 'CFE + CA' versus 'CFE' only compared to MBS-identified OPA. Early detection and appropriate management of OPA is important to prevent chronic pulmonary disease and poor growth in children. As the reliability of CFE to detect OPA is low, a technique that can improve the diagnostic accuracy of the CFE will help minimise consequences to the paediatric respiratory system. Cervical auscultation is a technique that has previously been documented as a clinical adjunct to the CFE; however, no published RCTs addressing the reliability of this technique in children exist. Our study will be the first to establish the utility of CA in assessing and diagnosing OPA risk in young children. Australia and New Zealand Clinical Trials Register (ANZCTR) number ACTRN12613000589785.
2013-01-01
Background Oropharyngeal aspiration (OPA) can lead to recurrent respiratory illnesses and chronic lung disease in children. Current clinical feeding evaluations performed by speech pathologists have poor reliability in detecting OPA when compared to radiological procedures such as the modified barium swallow (MBS). Improved ability to diagnose OPA accurately via clinical evaluation potentially reduces reliance on expensive, less readily available radiological procedures. Our study investigates the utility of adding cervical auscultation (CA), a technique of listening to swallowing sounds, in improving the diagnostic accuracy of a clinical evaluation for the detection of OPA. Methods We plan an open, unblinded, randomised controlled trial at a paediatric tertiary teaching hospital. Two hundred and sixteen children fulfilling the inclusion criteria will be randomised to one of the two clinical assessment techniques for the clinical detection of OPA: (1) clinical feeding evaluation only (CFE) group or (2) clinical feeding evaluation with cervical auscultation (CFE + CA) group. All children will then undergo an MBS to determine radiologically assessed OPA. The primary outcome is the presence or absence of OPA, as determined on MBS using the Penetration-Aspiration Scale. Our main objective is to determine the sensitivity, specificity, negative and positive predictive values of ‘CFE + CA’ versus ‘CFE’ only compared to MBS-identified OPA. Discussion Early detection and appropriate management of OPA is important to prevent chronic pulmonary disease and poor growth in children. As the reliability of CFE to detect OPA is low, a technique that can improve the diagnostic accuracy of the CFE will help minimise consequences to the paediatric respiratory system. Cervical auscultation is a technique that has previously been documented as a clinical adjunct to the CFE; however, no published RCTs addressing the reliability of this technique in children exist. Our study will be the first to establish the utility of CA in assessing and diagnosing OPA risk in young children. Trial registration Australia and New Zealand Clinical Trials Register (ANZCTR) number ACTRN12613000589785. PMID:24199872
Simulation of light transport in arthritic- and non-arthritic human fingers
NASA Astrophysics Data System (ADS)
Milanic, Matija; Paluchowski, Lukasz A.; Randeberg, Lise L.
2014-03-01
Rheumatoid arthritis is a disease that frequently leads to joint destruction. It has high incidence rates worldwide, and the disease significantly reduces patient's quality of life due to pain, swelling and stiffness of the affected joints. Early diagnosis is necessary to improve course of the disease, therefore sensitive and accurate diagnostic tools are required. Optical imaging techniques have capability for early diagnosis and monitoring of arthritis. As compared to conventional diagnostic techniques optical technique is a noninvasive, noncontact and fast way of collecting diagnostic information. However, a realistic model of light transport in human joints is needed for understanding and developing of such optical diagnostic tools. The aim of this study is to develop a 3D numerical model of light transport in a human finger. The model will guide development of a hyperspectral imaging (HSI) diagnostic modality for arthritis in human fingers. The implemented human finger geometry is based on anatomical data. Optical data of finger tissues are adjusted to represent either an arthritic or an unaffected finger. The geometry and optical data serve as input into a 3D Monte Carlo method, which calculate diffuse reflectance, transmittance and absorbed energy distributions. The parameters of the model are optimized based on HIS-measurements of human fingers. The presented model serves as an important tool for understanding and development of HSI as an arthritis diagnostic modality. Yet, it can be applied to other optical techniques and finger diseases.
Baer, F M
2007-09-01
The stress-ECG is the most often adopted and most cost effective initial diagnostic test for the assessment of myocardial ischemia in patients with suspected coronary artery disease (CAD). Prerequisites for the diagnostic usefullness of stress-ECG are a clearly interpretable ST-segment, ability to reach the predicted work load, an intermediate pretest probability for CAD ranging between 10% and 90% and the absence of any contraindications for dynamic exercise. Because of the limited diagnostic sensitivity of about 70%, and a high percentage of patients, who are unable to exercise, a negative stress ECG can definitely not exclude hemodynamically significant CAD. Therefore, stress imaging techniques like myocardial scintigraphy, stress-echocardiography and stress magnetic resonance imaging play a major role in the stepwise diagnostic work-up of patients with suspected CAD. These stress imaging techniques are basically interchangeable since no method is definitely superior to one of the others. However, each method has its specific pros and cons and inherent contraindications. Therefore the choice of the stress imaging method and the form of stress applied should be based on the individual patients characteristics to gain optimal image quality and diagnostic accuracy. Moreover, the decision for one method should take the local availability and institutional expertise of diagnostic centers into account. Although partly substituted by stress imaging techniques the stress-ECG still remains the workhorse for a stepwise diagnostic work-up of patients with suspected CAD.
READING DIAGNOSTIC APPROACHES.
ERIC Educational Resources Information Center
PURDY, ROBERT J.; AND OTHERS
A DIAGNOSTIC KIT DESIGNED TO HELP CLASSROOM TEACHERS DIAGNOSE READING DIFFICULTIES MORE ADEQUATELY AND MOTIVATE PUPILS MORE EFFECTIVELY IS PRESENTED. SUGGESTIONS ARE APPLICABLE TO LOWER PRIMARY CHILDREN. DIAGNOSTIC TECHNIQUES ARE OUTLINED FOR SUBJECTIVE AND OBJECTIVE OBSERVATION OF LANGUAGE ABILITY, VISUAL PERCEPTION SKILLS, AUDITORY…
NASA Astrophysics Data System (ADS)
Tornari, Vivi; Andrianakis, Michalis; Hatzigiannakis, Kostas; Kosma, Kiki; Detalle, Vincent; Giovanacci, David
2017-07-01
The demand for non destructive and non invasive structural diagnostic techniques able to perform on field remote structural evaluation of historical structures and works of art it faces an increased demand. The techniques must have some basic important characteristics The non destructivity, accuracy, repeatability, non physical contact, portability, resolution, broad range of applicability depending on the type of artwork and the question at hand, are all among the important requirements underlying the requirement for on-field structural diagnostics. In this respect there are two known techniques that have been developed at full to provide a suited structural diagnostic application in artwork conservation. The systems presented here but discussed in detail elsewhere are stimulated infrared thermography (SIRT) and digital holographic speckle pattern interferometry (DHSPI) the prior can be found n market at commercial devise level while the latter is at laboratory prototype level. The two systems are being exploited for their complimentary advantages and in this paper are used in combined testing on art related targets according to the above criteria to confirm the enhanced diagnostic information that their complimentary use provides. Results confirm the effectiveness of each technique alone and the combination of data of both techniques in the conservation field. Each system is first briefly described and examples are given with the aim to present the suitability and appropriateness for use in structural documentation analysis and reports. The experimental work is in laboratory work-in-progress focusing on the hybriding of data synthesis.
Hollow silica microspheres for buoyancy-assisted separation of infectious pathogens from stool.
Weigum, Shannon E; Xiang, Lichen; Osta, Erica; Li, Linying; López, Gabriel P
2016-09-30
Separation of cells and microorganisms from complex biological mixtures is a critical first step in many analytical applications ranging from clinical diagnostics to environmental monitoring for food and waterborne contaminants. Yet, existing techniques for cell separation are plagued by high reagent and/or instrumentation costs that limit their use in many remote or resource-poor settings, such as field clinics or developing countries. We developed an innovative approach to isolate infectious pathogens from biological fluids using buoyant hollow silica microspheres that function as "molecular buoys" for affinity-based target capture and separation by floatation. In this process, antibody functionalized glass microspheres are mixed with a complex biological sample, such as stool. When mixing is stopped, the target-bound, low-density microspheres float to the air/liquid surface, which simultaneously isolates and concentrates the target analytes from the sample matrix. The microspheres are highly tunable in terms of size, density, and surface functionality for targeting diverse analytes with separation times of ≤2min in viscous solutions. We have applied the molecular buoy technique for isolation of a protozoan parasite that causes diarrheal illness, Cryptosporidium, directly from stool with separation efficiencies over 90% and low non-specific binding. This low-cost method for phenotypic cell/pathogen separation from complex mixtures is expected to have widespread use in clinical diagnostics as well as basic research. Copyright © 2016 Elsevier B.V. All rights reserved.
Case Report: Severe Imported Influenza Infections Developed during Travel in Reunion Island.
Allyn, Jérôme; Brottet, Elise; Antok, Emmanuel; Dangers, Laurence; Persichini, Romain; Coolen-Allou, Nathalie; Roquebert, Bénédicte; Allou, Nicolas; Vandroux, David
2017-12-01
We report two cases of severe influenza infection imported by tourist patients from their country of origin and developed during travel. While studies have reported cases of influenza infections acquired during travel, here we examine two cases of severe influenza infection contracted in the country of origin that led to diagnosis and therapeutic problems in the destination country. No international recommendation exists concerning influenza vaccination before travel, and few countries recommend it for all travelers. Our study suggests that travel should be canceled when infectious signs are observed before departure. Influenza is a very common infection that is often benign, but sometimes very severe. The most severe cases include shock, acute respiratory distress syndrome (ARDS), myocarditis, rhabdomyolysis, and multiple organ failure. Management can require exceptional therapies, such as extracorporeal membrane oxygenation. A number of studies have focused on influenza infection in travelers. Cases of influenza acquired during travel have been reported in this literature, but no study has examined cases of influenza imported from the country of origin and developed while abroad. The latter situation may lead to 1) diagnostic problems during the nonepidemic season or in places where diagnostic techniques are lacking and 2) therapeutic difficulties resulting from the unavailability of techniques for the management of severe influenza infection in tourist areas. Here, we report two cases of extremely severe influenza infection imported by tourists from their country of origin and developed during travel.
Xu, Jiatuo; Wu, Hongjin; Lu, Luming; Tu, Liping; Zhang, Zhifeng; Chen, Xiao
2012-12-01
This paper is aimed to observe the difference of facial color of people with different health status by spectral photometric color measuring technique according to the theory of facial color diagnosis in Internal Classic. We gathered the facial color information about the health status of persons in healthy group (183), sub-healthy group (287) and disease group (370) respectively. The information included L, a, b, C values and reflection of different wavelengths in 400-700nm with CM-2600D spectral photometric color measuring instrument on 8 points. The results indicated that overall complexion color values of the people in the three groups were significantly different. The persons in the disease group looked deep dark in features. The people in the sub-healthy group looked pale in features. The loci L, a, b, C values were with varying degrees of significant differences (P < 0.05) at 6 points among the groups, and the central position of the face in all the groups was the position with most significant differences. Comparing the facial color information at the same point of the people in the three groups, we obtained each group's diagnostic special point. There existed diagnostic values in distinguishing disease status and various status of health in some degree by spectral photometric color measuring technique. The present method provides a prosperous quantitative basis for Chinese medical inspection of the complexion diagnosis.
Shimatani, Masaaki; Takaoka, Makoto; Tokuhara, Mitsuo; Miyoshi, Hideaki; Ikeura, Tsukasa; Okazaki, Kazuichi
2015-01-01
The endoscopic approach for biliary diseases in patients with surgically altered gastrointestinal anatomy (SAGA) had been generally deemed impractical. However, it was radically made feasible by the introduction of double balloon endoscopy (DBE) that was originally developed for diagnosis and treatments for small-bowel diseases. Followed by the subsequent development of single-balloon endoscopy (SBE) and spiral endoscopy (SE), interventions using several endoscopes for biliary disease in patients with SAGA widely gained an acceptance as a new modality. Many studies have been made on this new technique. Yet, some problems are to be solved. For instance, the mutual unavailability among devices due to different working lengths and channels, and unestablished standardization of procedural techniques can be raised. Additionally, in an attempt to standardize endoscopic procedures, it is important to evaluate biliary cannulating methods by case with existence of papilla or not. A full comprehension of the features of respective scope types is also required. However there are not many papers written as a review. In our manuscript, we would like to evaluate and make a review of the present status of diagnostic and therapeutic endoscopic retrograde cholangiopancreatography applying DBE, SBE and SE for biliary diseases in patients with SAGA for establishment of these modalities as a new technology and further improvement of the scopes and devices. PMID:26078830
Mubeen; K.R., Vijayalakshmi; Bhuyan, Sanat Kumar; Panigrahi, Rajat G; Priyadarshini, Smita R; Misra, Satyaranjan; Singh, Chandravir
2014-01-01
Objectives: The identification and radiographic interpretation of periapical bone lesions is important for accurate diagnosis and treatment. The present study was undertaken to study the feasibility and diagnostic accuracy of colour coded digital radiographs in terms of presence and size of lesion and to compare the diagnostic accuracy of colour coded digital images with direct digital images and conventional radiographs for assessing periapical lesions. Materials and Methods: Sixty human dry cadaver hemimandibles were obtained and periapical lesions were created in first and second premolar teeth at the junction of cancellous and cortical bone using a micromotor handpiece and carbide burs of sizes 2, 4 and 6. After each successive use of round burs, a conventional, RVG and colour coded image was taken for each specimen. All the images were evaluated by three observers. The diagnostic accuracy for each bur and image mode was calculated statistically. Results: Our results showed good interobserver (kappa > 0.61) agreement for the different radiographic techniques and for the different bur sizes. Conventional Radiography outperformed Digital Radiography in diagnosing periapical lesions made with Size two bur. Both were equally diagnostic for lesions made with larger bur sizes. Colour coding method was least accurate among all the techniques. Conclusion: Conventional radiography traditionally forms the backbone in the diagnosis, treatment planning and follow-up of periapical lesions. Direct digital imaging is an efficient technique, in diagnostic sense. Colour coding of digital radiography was feasible but less accurate however, this imaging technique, like any other, needs to be studied continuously with the emphasis on safety of patients and diagnostic quality of images. PMID:25584318
Roth, Kjetil; Hardie, Jon Andrew; Andreassen, Alf Henrik; Leh, Friedemann; Eagan, Tomas Mikal Lind
2009-06-01
The choice of sampling techniques in bronchoscopy with sampling from a visible lesion will depend on the expected diagnostic yields and the costs of the sampling techniques. The aim of this study was to determine the most economical combination of sampling techniques when approaching endobronchial visible lesions. A cost minimization analysis was performed. All bronchoscopies from 2003 and 2004 at Haukeland university hospital, Bergen, Norway, were reviewed retrospectively for diagnostic yields. 162 patients with endobronchial disease were included. Potential sampling techniques used were biopsy, brushing, endobronchial needle aspiration (EBNA) and washings. Costs were estimated based on registration of equipment costs and personnel costs. Sensitivity analyses were performed to determine threshold values. The combination of biopsy, brushing and EBNA was the most economical strategy with an average cost of Euro 893 (95% CI: 657, 1336). The cost of brushing had to be below Euro 83 and it had to increase the diagnostic yield more than 2.2%, for biopsy and brushing to be more economical than biopsy alone. The combination of biopsy, brushing and EBNA was more economical than biopsy and brushing when the cost of EBNA was below Euro 205 and the increase in diagnostic yield was above 5.2%. In the current study setting, biopsy, brushing and EBNA was the most economical combination of sampling techniques for endobronchial visible lesions.
Diagnostic Classification Models: Which One Should I Use?
ERIC Educational Resources Information Center
Jiao, Hong
2009-01-01
Diagnostic assessment is currently an active research area in educational measurement. Literature related to diagnostic modeling has been in existence for several decades, but a great deal of research has been conducted within the last decade or so, especially within the last five years. The author summarizes the key components in the application…
Instrumentation for localized superconducting cavity diagnostics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conway, Z. A.; Ge, M.; Iwashita, Y.
2017-01-12
Superconducting accelerator cavities are now routinely operated at levels approaching the theoretical limit of niobium. To achieve these operating levels more information than is available from the RF excitation signal is required to characterize and determine fixes for the sources of performance limitations. This information is obtained using diagnostic techniques which complement the analysis of the RF signal. In this paper we describe the operation and select results from three of these diagnostic techniques: the use of large scale thermometer arrays, second sound wave defect location and high precision cavity imaging with the Kyoto camera.
Decoding human swallowing via electroencephalography: a state-of-the-art review
Jestrović, Iva; Coyle, James L.
2015-01-01
Swallowing and swallowing disorders have garnered continuing interest over the past several decades. Electroencephalography (EEG) is an inexpensive and non-invasive procedure with very high temporal resolution which enables analysis of short and fast swallowing events, as well as an analysis of the organizational and behavioral aspects of cortical motor preparation, swallowing execution and swallowing regulation. EEG is a powerful technique which can be used alone or in combination with other techniques for monitoring swallowing, detection of swallowing motor imagery for diagnostic or biofeedback purposes, or to modulate and measure the effects of swallowing rehabilitation. This paper provides a review of the existing literature which has deployed EEG in the investigation of oropharyngeal swallowing, smell, taste and texture related to swallowing, cortical pre-motor activation in swallowing, and swallowing motor imagery detection. Furthermore, this paper provides a brief review of the different modalities of brain imaging techniques used to study swallowing brain activities, as well as the EEG components of interest for studies on swallowing and on swallowing motor imagery. Lastly, this paper provides directions for future swallowing investigations using EEG. PMID:26372528
Segura-Grau, A; Sáez-Fernández, A; Rodríguez-Lorenzo, A; Díaz-Rodríguez, N
2014-01-01
Ultrasound is a non-invasive, accessible, and versatile diagnostic technique that uses high frequency ultrasound waves to define outline the organs of the human body, with no ionising radiation, in real time and with the capacity to visual several planes. The high diagnostic yield of the technique, together with its ease of uses plus the previously mentioned characteristics, has currently made it a routine method in daily medical practice. It is for this reason that the multidisciplinary character of this technique is being strengthened every day. To be able to perform the technique correctly requires knowledge of the physical basis of ultrasound, the method and the equipment, as well as of the human anatomy, in order to have the maximum information possible to avoid diagnostic errors due to poor interpretation or lack of information. Copyright © 2013 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.
Diagnostics of wear in aeronautical systems
NASA Technical Reports Server (NTRS)
Wedeven, L. D.
1979-01-01
The use of appropriate diagnostic tools for aircraft oil wetted components is reviewed, noting that it can reduce direct operating costs through reduced unscheduled maintenance, particularly in helicopter engine and transmission systems where bearing failures are a significant cost factor. Engine and transmission wear modes are described, and diagnostic methods for oil and wet particle analysis, the spectrometric oil analysis program, chip detectors, ferrography, in-line oil monitor and radioactive isotope tagging are discussed, noting that they are effective over a limited range of particle sizes but compliment each other if used in parallel. Fine filtration can potentially increase time between overhauls, but reduces the effectiveness of conventional oil monitoring techniques so that alternative diagnostic techniques must be used. It is concluded that the development of a diagnostic system should be parallel and integral with the development of a mechanical system.
The Evolutionary Development of Echocardiography
Maleki, Majid; Esmaeilzadeh, Maryam
2012-01-01
Echocardiography is a non-invasive diagnostic technique which provides information on cardiac morphology, function, and hemodynamics. It is the most frequently used cardiovascular diagnostic test only after electrocardiography. In less than five decades, the evolution in this technique has made it the basic part of cardiovascular medicine. Herein, the evolution of various forms of echocardiography is briefly described. PMID:23390327
Ultrasound of the thyroid and parathyroid glands.
Barraclough, B M; Barraclough, B H
2000-02-01
The superficial position of thyroid and parathyroid glands facilitates the use of diagnostic ultrasound (US) as an imaging technique. Techniques of image acquisition and interpretation are described in detail. Size and morphology of glands can be defined easily. The most important use of US guided biopsy in relation to thyroid and parathyroid glands is to increase diagnostic accuracy.
ERIC Educational Resources Information Center
Nelson, Karin Zetterqvist
2011-01-01
The present article examines the development of a diagnostic and therapeutic technique named The Sandtray at the Erica Foundation, a privately-run child counselling service in Stockholm. Originally it was called The World, developed by the British paediatrician and child psychiatrist Margaret Lowenfeld. In the 1930s it was imported to Sweden,…
NASA Astrophysics Data System (ADS)
Salyer, Terry
2017-06-01
For the bulk of detonation performance experiments, a fairly basic set of diagnostic techniques has evolved as the standard for acquiring the necessary measurements. Gold standard techniques such as pin switches and streak cameras still produce the high-quality data required, yet much room remains for improvement with regard to ease of use, cost of fielding, breadth of data, and diagnostic versatility. Over the past several years, an alternate set of diagnostics has been under development to replace many of these traditional techniques. Pulse Correlation Reflectometry (PCR) is a capable substitute for pin switches with the advantage of obtaining orders of magnitude more data at a small fraction of the cost and fielding time. Spectrally Encoded Imaging (SEI) can replace most applications of streak camera with the advantage of imaging surfaces through a single optical fiber that are otherwise optically inaccessible. Such diagnostics advance the measurement state of the art, but even further improvements may come through revamping the standardized tests themselves such as the copper cylinder expansion test. At the core of this modernization, the aforementioned diagnostics play a significant role in revamping and improving the standard test suite for the present era. This research was performed under the auspices of the United States Department of Energy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabot, A.; Petit, A.; Taillebois, J.P.
1996-07-01
This paper summarizes the Electricite de France experience with insulation co-ordination of GIS. After a review of the insulation co-ordination practice mainly dealing with fast front overvoltage and the one minute AC test, some results of the on-site test procedure applied since 30 years are presented and related to the insulation co-ordination practice. The in-service return of experience dealing with dielectric failures is analyzed then the dielectric diagnostic techniques now available are briefly presented with their possibilities and limitations. According to this survey, the expectations of EDF from these diagnostic techniques as well as the new on-site test and on-linemore » monitoring tendencies at EDF are presented.« less
Qualitative and quantitative detection of T7 bacteriophages using paper based sandwich ELISA.
Khan, Mohidus Samad; Pande, Tripti; van de Ven, Theo G M
2015-08-01
Viruses cause many infectious diseases and consequently epidemic health threats. Paper based diagnostics and filters can offer attractive options for detecting and deactivating pathogens. However, due to their infectious characteristics, virus detection using paper diagnostics is more challenging compared to the detection of bacteria, enzymes, DNA or antigens. The major objective of this study was to prepare reliable, degradable and low cost paper diagnostics to detect viruses, without using sophisticated optical or microfluidic analytical instruments. T7 bacteriophage was used as a model virus. A paper based sandwich ELISA technique was developed to detect and quantify the T7 phages in solution. The paper based sandwich ELISA detected T7 phage concentrations as low as 100 pfu/mL to as high as 10(9) pfu/mL. The compatibility of paper based sandwich ELISA with the conventional titre count was tested using T7 phage solutions of unknown concentrations. The paper based sandwich ELISA technique is faster and economical compared to the traditional detection techniques. Therefore, with proper calibration and right reagents, and by following the biosafety regulations, the paper based technique can be said to be compatible and economical to the sophisticated laboratory diagnostic techniques applied to detect pathogenic viruses and other microorganisms. Copyright © 2015 Elsevier B.V. All rights reserved.
Improved Signal Processing Technique Leads to More Robust Self Diagnostic Accelerometer System
NASA Technical Reports Server (NTRS)
Tokars, Roger; Lekki, John; Jaros, Dave; Riggs, Terrence; Evans, Kenneth P.
2010-01-01
The self diagnostic accelerometer (SDA) is a sensor system designed to actively monitor the health of an accelerometer. In this case an accelerometer is considered healthy if it can be determined that it is operating correctly and its measurements may be relied upon. The SDA system accomplishes this by actively monitoring the accelerometer for a variety of failure conditions including accelerometer structural damage, an electrical open circuit, and most importantly accelerometer detachment. In recent testing of the SDA system in emulated engine operating conditions it has been found that a more robust signal processing technique was necessary. An improved accelerometer diagnostic technique and test results of the SDA system utilizing this technique are presented here. Furthermore, the real time, autonomous capability of the SDA system to concurrently compensate for effects from real operating conditions such as temperature changes and mechanical noise, while monitoring the condition of the accelerometer health and attachment, will be demonstrated.
Active and Passive Diagnostic Signatures of Special Nuclear Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myers, William L.; Karpius, Peter Joseph; Myers, Steven Charles
2017-05-26
An overview will be given discussing signatures associated with special nuclear materials acquired using both active and passive diagnostic techniques. Examples of how technology advancements have helped improve diagnostic capabilities to meet the challenges of today’s applications will be discussed.
MEMS-Based Power Generation Techniques for Implantable Biosensing Applications
Lueke, Jonathan; Moussa, Walied A.
2011-01-01
Implantable biosensing is attractive for both medical monitoring and diagnostic applications. It is possible to monitor phenomena such as physical loads on joints or implants, vital signs, or osseointegration in vivo and in real time. Microelectromechanical (MEMS)-based generation techniques can allow for the autonomous operation of implantable biosensors by generating electrical power to replace or supplement existing battery-based power systems. By supplementing existing battery-based power systems for implantable biosensors, the operational lifetime of the sensor is increased. In addition, the potential for a greater amount of available power allows additional components to be added to the biosensing module, such as computational and wireless and components, improving functionality and performance of the biosensor. Photovoltaic, thermovoltaic, micro fuel cell, electrostatic, electromagnetic, and piezoelectric based generation schemes are evaluated in this paper for applicability for implantable biosensing. MEMS-based generation techniques that harvest ambient energy, such as vibration, are much better suited for implantable biosensing applications than fuel-based approaches, producing up to milliwatts of electrical power. High power density MEMS-based approaches, such as piezoelectric and electromagnetic schemes, allow for supplemental and replacement power schemes for biosensing applications to improve device capabilities and performance. In addition, this may allow for the biosensor to be further miniaturized, reducing the need for relatively large batteries with respect to device size. This would cause the implanted biosensor to be less invasive, increasing the quality of care received by the patient. PMID:22319362
Immunohistochemistry: forging the links between immunology and pathology.
Haines, Deborah M; West, Keith H
2005-10-18
The technique of immunohistochemical staining allows the visualization of epitopes in situ in histological tissue sections. A series of innovations in the methods and reagents and the introduction of mechanization have enhanced the ease and technical reliability of this technique resulting in widespread application in veterinary diagnostics and research. This brief overview will highlight some of the applications for immunohistochemical staining with an emphasis on the use of the technique in diagnostic veterinary medicine, particularly for the detection of infectious disease agents.
The Development of a Post-Baccalaureate Certificate Program in Molecular Diagnostics
Williams, Gail S.; Brown, Judith D.; Keagle, Martha B.
2000-01-01
A post-baccalaureate certificate program in diagnostic molecular sciences was created in 1995 by the Diagnostic Genetic Sciences Program in the School of Allied Health at the University of Connecticut. The required on-campus lecture and laboratory courses include basic laboratory techniques, health care issues, cell biology, immunology, human genetics, research, management, and molecular diagnostic techniques and laboratory in molecular diagnostics. These courses precede a 6-month, full-time practicum at an affiliated full-service molecular laboratory. The practicum includes amplification and blotting methods, a research project, and a choice of specialized electives including DNA sequencing, mutagenesis, in situ hybridization methods, or molecular diagnostic applications in microbiology. Graduates of the program are immediately eligible to sit for the National Credentialing Agency examination in molecular biology to obtain the credential Clinical Laboratory Specialist in Molecular Biology (CLSp(MB). This description of the University of Connecticut program may assist other laboratory science programs in creating similar curricula. PMID:11232107
ERIC Educational Resources Information Center
Sun, Xiang; Allison, Carrie; Auyeung, Bonnie; Zhang, Zhixiang; Matthews, Fiona E.; Baron-Cohen, Simon; Brayne, Carol
2015-01-01
Research to date in mainland China has mainly focused on children with autistic disorder rather than Autism Spectrum Conditions and the diagnosis largely depended on clinical judgment without the use of diagnostic instruments. Whether children who have been diagnosed in China before meet the diagnostic criteria of Autism Spectrum Conditions is not…
In situ surface/interface x-ray diffractometer for oxide molecular beam epitaxy
NASA Astrophysics Data System (ADS)
Lee, J. H.; Tung, I. C.; Chang, S.-H.; Bhattacharya, A.; Fong, D. D.; Freeland, J. W.; Hong, Hawoong
2016-01-01
In situ studies of oxide molecular beam epitaxy by synchrotron x-ray scattering has been made possible by upgrading an existing UHV/molecular beam epitaxy (MBE) six-circle diffractometer system. For oxide MBE growth, pure ozone delivery to the chamber has been made available, and several new deposition sources have been made available on a new 12 in. CF (ConFlat, a registered trademark of Varian, Inc.) flange. X-ray diffraction has been used as a major probe for film growth and structures for the system. In the original design, electron diffraction was intended for the secondary diagnostics available without the necessity of the x-ray and located at separate positions. Deposition of films was made possible at the two diagnostic positions. And, the aiming of the evaporation sources is fixed to the point between two locations. Ozone can be supplied through two separate nozzles for each location. Also two separate thickness monitors are installed. Additional features of the equipment are also presented together with the data taken during typical oxide film growth to illustrate the depth of information available via in situ x-ray techniques.
In situ surface/interface x-ray diffractometer for oxide molecular beam epitaxy.
Lee, J H; Tung, I C; Chang, S-H; Bhattacharya, A; Fong, D D; Freeland, J W; Hong, Hawoong
2016-01-01
In situ studies of oxide molecular beam epitaxy by synchrotron x-ray scattering has been made possible by upgrading an existing UHV/molecular beam epitaxy (MBE) six-circle diffractometer system. For oxide MBE growth, pure ozone delivery to the chamber has been made available, and several new deposition sources have been made available on a new 12 in. CF (ConFlat, a registered trademark of Varian, Inc.) flange. X-ray diffraction has been used as a major probe for film growth and structures for the system. In the original design, electron diffraction was intended for the secondary diagnostics available without the necessity of the x-ray and located at separate positions. Deposition of films was made possible at the two diagnostic positions. And, the aiming of the evaporation sources is fixed to the point between two locations. Ozone can be supplied through two separate nozzles for each location. Also two separate thickness monitors are installed. Additional features of the equipment are also presented together with the data taken during typical oxide film growth to illustrate the depth of information available via in situ x-ray techniques.
Reis, Leonardo O.; Barreiro, Guilherme C.; Prudente, Alessandro; Silva, Cleide M.; Bassani, José W. M.; D'Ancona, Carlos A. L.
2009-01-01
Objectives. Using a urethral device at the fossa navicularis, bladder pressure during voiding can be estimated by a minimal invasive technique. This study purposes a new diagnostic index for patients with lower urinary tract symptoms (LUTSs). Methods. Fifty one patients presenting with LUTSs were submitted to a conventional urodynamic and a minimal invasive study. The results obtained through the urethral device and invasive classic urodynamics were compared. The existing bladder outlet obstruction index (BOOI) equation that classifies men with LUTSs was modified to allow minimal invasive measurement of isovolumetric bladder pressure in place of detrusor pressure at maximum urine flow. Accuracy of the new equation for classifying obstruction was then tested in this group of men. Results. The modified equation identified men with obstruction with a positive predictive value of 68% and a negative predictive value of 70%, with an overall accuracy of 70%. Conclusions. The proposed equation can accurately classify over 70% of men without resorting to invasive pressure flow studies. We must now evaluate the usefulness of this classification for the surgical treatment of men with LUTSs. PMID:19125194
Nanoparticles for Improving Cancer Diagnosis
Chen, Hongmin; Zhen, Zipeng; Todd, Trever; Chu, Paul K.; Xie, Jin
2013-01-01
Despite the progress in developing new therapeutic modalities, cancer remains one of the leading diseases causing human mortality. This is mainly attributed to the inability to diagnose tumors in their early stage. By the time the tumor is confirmed, the cancer may have already metastasized, thereby making therapies challenging or even impossible. It is therefore crucial to develop new or to improve existing diagnostic tools to enable diagnosis of cancer in its early or even pre-syndrome stage. The emergence of nanotechnology has provided such a possibility. Unique physical and physiochemical properties allow nanoparticles to be utilized as tags with excellent sensitivity. When coupled with the appropriate targeting molecules, nanoparticle-based probes can interact with a biological system and sense biological changes on the molecular level with unprecedented accuracy. In the past several years, much progress has been made in applying nanotechnology to clinical imaging and diagnostics, and interdisciplinary efforts have made an impact on clinical cancer management. This article aims to review the progress in this exciting area with emphases on the preparation and engineering techniques that have been developed to assemble “smart” nanoprobes. PMID:24068857
Percutaneous CT-guided biopsy of the spine: results of 430 biopsies
Rimondi, Eugenio; Errani, Costantino; Bianchi, Giuseppe; Casadei, Roberto; Alberghini, Marco; Malaguti, Maria Cristina; Rossi, Giuseppe; Durante, Stefano; Mercuri, Mario
2008-01-01
Biopsies of lesions in the spine are often challenging procedures with significant risk of complications. CT-guided needle biopsies could lower these risks but uncertainties still exist about the diagnostic accuracy. Aim of this retrospective study was to evaluate the diagnostic accuracy of CT-guided needle biopsies for bone lesions of the spine. We retrieved the results of 430 core needle biopsies carried out over the past fifteen years at the authors’ institute and examined the results obtained. Of the 430 biopsies performed, in 401 cases the right diagnosis was made with the first CT-guided needle biopsy (93.3% accuracy rate). Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, inflammatory, and systemic pathologies. There were only 9 complications (5 transient paresis, 4 haematomas that resolved spontaneously) that had no influence on the treatment strategy, nor on the patient’s outcome. In conclusion we can assert that this technique is reliable and safe and should be considered the gold standard in biopsies of the spine. PMID:18463900
Design of multichannel laser interferometry for W7-X
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kornejew, P.; Hirsch, M.; Bindemann, T.
2006-10-15
An eight channel interferometer is developed for density feedback control and the continuous measurement of electron density profiles in the stellarator W7-X. An additional sightline is launched in the geometry of the Thomson scattering for cross calibration. Due to the W7-X coil geometry access is strongly restricted. This motivates the optimization of the sightline geometry and design studies for supplementary chords. In-vessel retroreflectors will be used and inserted in the first wall elements. To cope with associated mechanical vibrations and thermal drifts during the discharges with envisaged duration of 30 min either two-color or second harmonic interferometry techniques must bemore » applied. Optimum wavelengths are found to be about 10 and 5 {mu}m. A CO{sub 2}/CO interferometer (10 {mu}m/5 {mu}m) will be tested and compared with an existing CO{sub 2}/HeNe test interferometer. A special difficulty of remotely operated diagnostics is the need of long transmission lines with a path length of about 60 m required from the diagnostics location to the torus hall and back. Different arrangements will be compared.« less
[Diagnostic and therapeutic approach to pancreatic trauma].
Vidali, Maria; Doulgerakis, George; Condilis, Nicolas; Karmiri, Eleni; Poygouras, Ihon; Papaioannoy, George; Ioannoy, Christos; Pierrakakis, Stefanos; Setakis, Nicolas
2005-01-01
The pancreatic trauma is rare, compared with the injuries of the other abdominal organs and occurs in 0.2-6 per cent of the cases of abdominal trauma. The aim of this essay is to demonstrate the Authors' experience in the treatment of five cases of pancreatic injury during the last five years, as well as to retrospect the contemporary bibliography, connected with the diagnostic and curative approach of the pancreatic trauma. The diagnosis of the pancreatic trauma is difficult and many times, late. In their experience of pancreatic trauma, the Authors ascertained the pancreatic injury during the laparotomy which was made in order to treat other abdominal injuries. The surgical techniques were chosen taking into account the extent of the injury, the detection and the existence of accompanying. Marginal resection of pancreas, splenectomy and drainage were applied to three patients, suture of the pancreas and drainage to one patient, drainage alone and treatment of synchronous rupture of the duodenum to one patient. The mortality was 0%. Came whereas the morbidity came basically on the seriousness of the accompanying injuries.
Sun, Xiang; Allison, Carrie; Auyeung, Bonnie; Zhang, Zhixiang; Matthews, Fiona E; Baron-Cohen, Simon; Brayne, Carol
2015-11-01
Research to date in mainland China has mainly focused on children with autistic disorder rather than Autism Spectrum Conditions and the diagnosis largely depended on clinical judgment without the use of diagnostic instruments. Whether children who have been diagnosed in China before meet the diagnostic criteria of Autism Spectrum Conditions is not known nor how many such children would meet these criteria. The aim of this study was to evaluate children with a known diagnosis of autism in mainland China using the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview-Revised to verify that children who were given a diagnosis of autism made by Chinese clinicians in China were mostly children with severe autism. Of 50 children with an existing diagnosis of autism made by Chinese clinicians, 47 children met the diagnosis of autism on the Autism Diagnostic Observation Schedule algorithm and 44 children met the diagnosis of autism on the Autism Diagnostic Interview-Revised algorithm. Using the Gwet's alternative chance-corrected statistic, the agreement between the Chinese diagnosis and the Autism Diagnostic Observation Schedule diagnosis was very good (AC1 = 0.94, p < 0.005, 95% confidence interval (0.86, 1.00)), so was the agreement between the Chinese diagnosis and the Autism Diagnostic Interview-Revised (AC1 = 0.91, p < 0.005, 95% confidence interval (0.81, 1.00)). The agreement between the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview-Revised was lower but still very good (AC1 = 0.83, p < 0.005). © The Author(s) 2015.
Sun, Xiang; Allison, Carrie; Auyeung, Bonnie; Zhang, Zhixiang; Matthews, Fiona E; Baron-Cohen, Simon; Brayne, Carol
2016-01-01
Research to date in mainland China has mainly focused on children with autistic disorder rather than Autism Spectrum Conditions and the diagnosis largely depended on clinical judgment without the use of diagnostic instruments. Whether children who have been diagnosed in China before meet the diagnostic criteria of Autism Spectrum Conditions is not known nor how many such children would meet these criteria. The aim of this study was to evaluate children with a known diagnosis of autism in mainland China using the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview–Revised to verify that children who were given a diagnosis of autism made by Chinese clinicians in China were mostly children with severe autism. Of 50 children with an existing diagnosis of autism made by Chinese clinicians, 47 children met the diagnosis of autism on the Autism Diagnostic Observation Schedule algorithm and 44 children met the diagnosis of autism on the Autism Diagnostic Interview–Revised algorithm. Using the Gwet’s alternative chance-corrected statistic, the agreement between the Chinese diagnosis and the Autism Diagnostic Observation Schedule diagnosis was very good (AC1 = 0.94, p < 0.005, 95% confidence interval (0.86, 1.00)), so was the agreement between the Chinese diagnosis and the Autism Diagnostic Interview–Revised (AC1 = 0.91, p < 0.005, 95% confidence interval (0.81, 1.00)). The agreement between the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview–Revised was lower but still very good (AC1 = 0.83, p < 0.005). PMID:25757721
ERIC Educational Resources Information Center
Rose, Mike
1999-01-01
Examines, within a situated-cognition framework, the teaching and learning of a concept in biomechanics, the manual techniques and tactile discrimination skills that accompany it, and the diagnostic frame of mind that informs concept, technique, and skill. Draws on observations of a class of physical-therapy students. (Author/SLD)
ERIC Educational Resources Information Center
Hsu, Pi-Shan; Chang, Te-Jeng; Wu, Ming-Hsiung
2009-01-01
The level of learners' expertise has been used as a metric and diagnostic mechanism of instruction. This metric influences mental effort directly according to the applications of cognitive load theory. Cognitive efficiency, an optimal measurement technique of expertise, was developed by Kalyuga and Sweller to replace instructional efficiency in…
Zhang, Nan; Fan, Zhaoyang; Luo, Nan; Bi, Xiaoming; Zhao, Yike; An, Jing; Liu, Jiayi; Chen, Zhong; Fan, Zhanming; Li, Debiao
2015-01-01
Purpose To evaluate the feasibility and diagnostic performance of flow-sensitive dephasing (FSD)-prepared steady-state free precession (SSFP) MR angiography (MRA) for imaging infragenual arteries at 3.0T, with contrast enhanced MR angiography (CE MRA) as reference. Materials And Methods Twenty consecutive patients with suspicion of lower extremity arterial disease undergoing routine CE MRA were recruited. FSD MRA was performed at calf before CE MRA. Image quality and stenosis degree of infragenual arteries from both techniques were independently evaluated and compared. Six patients in this study underwent DSA examination. Results Three undiagnostic segments were excluded with severe venous contamination in CE MRA. A total of 197 calf arterial segments images were analyzed. No significant difference existed in the relative signal intensity (rSI) of arterial segments between FSD MRA and CE MRA techniques (0.92±0.09 vs. 0.93±0.05; P=0.207). However, the subjective image quality score was slightly higher in FSD MRA (3.66±0.81 vs. 3.49±0.87; P=0.050). With CE MRA images as reference standard, slight overestimation existed in FSD MRA (2.19±1.24 vs. 2.09±1.18; P=0.019), with total agreement of 84.3% on the basis of all arterial segments. The sensitivity, specificity, NPV, and PPV of FSD MRA was 96.4%, 93.0%, 98.5%, and 84.1%. No significant difference in the stenosis degree score was detected between MRA (FSD MRA and CE MRA) and DSA (P > 0.05). Conclusion FSD MRA performed on at 3.0Twithout the use of contrast medium provides diagnostic images allowing for arterial stenosis assessment of calf arteries that was highly comparable with CE MRA. Moreover, venous contamination was less problematic with FSD MRA. PMID:26185106
Timely Diagnostic Feedback for Database Concept Learning
ERIC Educational Resources Information Center
Lin, Jian-Wei; Lai, Yuan-Cheng; Chuang, Yuh-Shy
2013-01-01
To efficiently learn database concepts, this work adopts association rules to provide diagnostic feedback for drawing an Entity-Relationship Diagram (ERD). Using association rules and Asynchronous JavaScript and XML (AJAX) techniques, this work implements a novel Web-based Timely Diagnosis System (WTDS), which provides timely diagnostic feedback…
NASA Astrophysics Data System (ADS)
Hiwarkar, V. R.; Babitsky, V. I.; Silberschmidt, V. V.
2013-07-01
Numerous techniques are available for monitoring structural health. Most of these techniques are expensive and time-consuming. In this paper, vibration-based techniques are explored together with their use as diagnostic tools for structural health monitoring. Finite-element simulations are used to study the effect of material nonlinearity on dynamics of a cracked bar. Additionally, several experiments are performed to study the effect of vibro-impact behavior of crack on its dynamics. It was observed that a change in the natural frequency of the cracked bar due to crack-tip plasticity and vibro-impact behavior linked to interaction of crack faces, obtained from experiments, led to generation of higher harmonics; this can be used as a diagnostic tool for structural health monitoring.
Webb, Camille; Cabada, Miguel M
2017-10-01
Cestodes infections in humans are among the most prevalent parasitosis worldwide. Although tapeworm infection is often asymptomatic, they can be associated with a range of symptoms. The landscape of cestode infections is changing with rapid diagnosis techniques and advanced molecular diagnosis aiding in identification of species specific epidemiology. Traditional descriptions of species by location have been challenged with molecular diagnostic techniques, which show variation in distribution of species, thought to be because of globalization and importation of disease. Epidemiology, molecular diagnostic techniques. Infection by tapeworms is often asymptomatic or accompanied by mild symptoms though can occasionally cause severe disease and contribute to anemia and malnutrition. Tapeworm infection is most prevalent in resource-poor countries but the distribution is worldwide. Epidemiology of infection is changing because of molecular diagnostics, which allow more accurate tracking of species.
Sjöstrand, Henrik; Andersson Sundén, E; Conroy, S; Ericsson, G; Gatu Johnson, M; Giacomelli, L; Gorini, G; Hellesen, C; Hjalmarsson, A; Popovichev, S; Ronchi, E; Tardocchi, M; Weiszflog, M
2009-06-01
Burning plasma experiments such as ITER and DEMO require diagnostics capable of withstanding the harsh environment generated by the intense neutron flux and to maintain stable operating conditions for times longer than present day systems. For these reasons, advanced control and monitoring (CM) systems will be necessary for the reliable operation of diagnostics. This paper describes the CM system of the upgraded magnetic proton recoil neutron spectrometer installed at the Joint European Torus focusing in particular on a technique for the stabilization of the gain of the photomultipliers coupled to the neutron detectors. The results presented here show that this technique provides good results over long time scales. The technique is of general interest for all diagnostics that employ scintillators coupled to photomultiplier tubes.
Mugambi, Robert Muriuki; Agola, Eric L; Mwangi, Ibrahim N; Kinyua, Johnson; Shiraho, Esther Andia; Mkoji, Gerald M
2015-11-06
Hookworm infection is a major concern in sub-Saharan Africa, particularly in children and pregnant women. Necator americanus and Ancylostoma duodenale are responsible for this condition. Hookworm disease is one of the Neglected tropical diseases (NTDs) that are targeted for elimination through global mass chemotherapy. To support this there is a need for reliable diagnostic tools. The conventional diagnostic test, Kato-Katz that is based on microscopic detection of parasite ova in faecal samples, is not effective due to its low sensitivity that is brought about mainly by non-random distribution of eggs in stool and day to day variation in egg output. It is tedious, cumbersome to perform and requires experience for correct diagnosis. LAMP-based tests are simple, relatively cheap, offer greater sensitivity, specificity than existing tests, have high throughput capability, and are ideal for use at the point of care. We have developed a LAMP diagnostic test for detection of hookworm infection in faecal samples. LAMP relies on auto cycling strand displacement DNA synthesis performed at isothermal temperature by Bst polymerase and a set of 4 specific primers. The primers used in the LAMP assay were based on the second Internal Transcribed Spacer (ITS-2) region and designed using Primer Explorer version 4 Software. The ITS-2 region of the ribosomal gene (rDNA) was identified as a suitable target due to its low mutation rates and substantial differences between species. DNA was extracted directly from human faecal samples, followed by LAMP amplification at isothermal temperature of 63 °C for 1 h. Amplicons were visualized using gel electrophoresis and SYBR green dye. Both specificity and sensitivity of the assay were determined. The LAMP based technique developed was able to detect N. americanus DNA in faecal samples. The assay showed 100 % specificity and no cross-reaction was observed with other helminth parasites (S. mansoni, A. lumbricoides or T. trichiura). The developed LAMP assay was 97 % sensitive and DNA at concentrations as low as 0.4 fg were amplified. The LAMP assay developed is an appropriate diagnostic method for the detection of N. americanus DNA in human stool samples because of its simplicity, low cost, sensitivity, and specificity. It holds great promise as a useful diagnostic tool for use in disease control where infection intensities have been significantly reduced.
Wu, Jianglai; Tang, Anson H. L.; Mok, Aaron T. Y.; Yan, Wenwei; Chan, Godfrey C. F.; Wong, Kenneth K. Y.; Tsia, Kevin K.
2017-01-01
Apart from the spatial resolution enhancement, scaling of temporal resolution, equivalently the imaging throughput, of fluorescence microscopy is of equal importance in advancing cell biology and clinical diagnostics. Yet, this attribute has mostly been overlooked because of the inherent speed limitation of existing imaging strategies. To address the challenge, we employ an all-optical laser-scanning mechanism, enabled by an array of reconfigurable spatiotemporally-encoded virtual sources, to demonstrate ultrafast fluorescence microscopy at line-scan rate as high as 8 MHz. We show that this technique enables high-throughput single-cell microfluidic fluorescence imaging at 75,000 cells/second and high-speed cellular 2D dynamical imaging at 3,000 frames per second, outperforming the state-of-the-art high-speed cameras and the gold-standard laser scanning strategies. Together with its wide compatibility to the existing imaging modalities, this technology could empower new forms of high-throughput and high-speed biological fluorescence microscopy that was once challenged. PMID:28966855
A method to classify schizophrenia using inter-task spatial correlations of functional brain images.
Michael, Andrew M; Calhoun, Vince D; Andreasen, Nancy C; Baum, Stefi A
2008-01-01
The clinical heterogeneity of schizophrenia (scz) and the overlap of self reported and observed symptoms with other mental disorders makes its diagnosis a difficult task. At present no laboratory-based or image-based diagnostic tool for scz exists and such tools are desired to support existing methods for more precise diagnosis. Functional magnetic resonance imaging (fMRI) is currently employed to identify and correlate cognitive processes related to scz and its symptoms. Fusion of multiple fMRI tasks that probe different cognitive processes may help to better understand hidden networks of this complex disorder. In this paper we utilize three different fMRI tasks and introduce an approach to classify subjects based on inter-task spatial correlations of brain activation. The technique was applied to groups of patients and controls and its validity was checked with the leave-one-out method. We show that the classification rate increases when information from multiple tasks are combined.
Thomas, Minta; De Brabanter, Kris; De Moor, Bart
2014-05-10
DNA microarrays are potentially powerful technology for improving diagnostic classification, treatment selection, and prognostic assessment. The use of this technology to predict cancer outcome has a history of almost a decade. Disease class predictors can be designed for known disease cases and provide diagnostic confirmation or clarify abnormal cases. The main input to this class predictors are high dimensional data with many variables and few observations. Dimensionality reduction of these features set significantly speeds up the prediction task. Feature selection and feature transformation methods are well known preprocessing steps in the field of bioinformatics. Several prediction tools are available based on these techniques. Studies show that a well tuned Kernel PCA (KPCA) is an efficient preprocessing step for dimensionality reduction, but the available bandwidth selection method for KPCA was computationally expensive. In this paper, we propose a new data-driven bandwidth selection criterion for KPCA, which is related to least squares cross-validation for kernel density estimation. We propose a new prediction model with a well tuned KPCA and Least Squares Support Vector Machine (LS-SVM). We estimate the accuracy of the newly proposed model based on 9 case studies. Then, we compare its performances (in terms of test set Area Under the ROC Curve (AUC) and computational time) with other well known techniques such as whole data set + LS-SVM, PCA + LS-SVM, t-test + LS-SVM, Prediction Analysis of Microarrays (PAM) and Least Absolute Shrinkage and Selection Operator (Lasso). Finally, we assess the performance of the proposed strategy with an existing KPCA parameter tuning algorithm by means of two additional case studies. We propose, evaluate, and compare several mathematical/statistical techniques, which apply feature transformation/selection for subsequent classification, and consider its application in medical diagnostics. Both feature selection and feature transformation perform well on classification tasks. Due to the dynamic selection property of feature selection, it is hard to define significant features for the classifier, which predicts classes of future samples. Moreover, the proposed strategy enjoys a distinctive advantage with its relatively lesser time complexity.
Two-dimensional Imaging Velocity Interferometry: Technique and Data Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erskine, D J; Smith, R F; Bolme, C
2011-03-23
We describe the data analysis procedures for an emerging interferometric technique for measuring motion across a two-dimensional image at a moment in time, i.e. a snapshot 2d-VISAR. Velocity interferometers (VISAR) measuring target motion to high precision have been an important diagnostic in shockwave physics for many years Until recently, this diagnostic has been limited to measuring motion at points or lines across a target. We introduce an emerging interferometric technique for measuring motion across a two-dimensional image, which could be called a snapshot 2d-VISAR. If a sufficiently fast movie camera technology existed, it could be placed behind a traditional VISARmore » optical system and record a 2d image vs time. But since that technology is not yet available, we use a CCD detector to record a single 2d image, with the pulsed nature of the illumination providing the time resolution. Consequently, since we are using pulsed illumination having a coherence length shorter than the VISAR interferometer delay ({approx}0.1 ns), we must use the white light velocimetry configuration to produce fringes with significant visibility. In this scheme, two interferometers (illuminating, detecting) having nearly identical delays are used in series, with one before the target and one after. This produces fringes with at most 50% visibility, but otherwise has the same fringe shift per target motion of a traditional VISAR. The 2d-VISAR observes a new world of information about shock behavior not readily accessible by traditional point or 1d-VISARS, simultaneously providing both a velocity map and an 'ordinary' snapshot photograph of the target. The 2d-VISAR has been used to observe nonuniformities in NIF related targets (polycrystalline diamond, Be), and in Si and Al.« less
Scott, Bobby R.; Di Palma, Jennifer
2007-01-01
Routine diagnostic X-rays (e.g., chest X-rays, mammograms, computed tomography scans) and routine diagnostic nuclear medicine procedures using sparsely ionizing radiation forms (e.g., beta and gamma radiations) stimulate the removal of precancerous neo-plastically transformed and other genomically unstable cells from the body (medical radiation hormesis). The indicated radiation hormesis arises because radiation doses above an individual-specific stochastic threshold activate a system of cooperative protective processes that include high-fidelity DNA repair/apoptosis (presumed p53 related), an auxiliary apoptosis process (PAM process) that is presumed p53-independent, and stimulated immunity. These forms of induced protection are called adapted protection because they are associated with the radiation adaptive response. Diagnostic X-ray sources, other sources of sparsely ionizing radiation used in nuclear medicine diagnostic procedures, as well as radioisotope-labeled immunoglobulins could be used in conjunction with apopto-sis-sensitizing agents (e.g., the natural phenolic compound resveratrol) in curing existing cancer via low-dose fractionated or low-dose, low-dose-rate therapy (therapeutic radiation hormesis). Evidence is provided to support the existence of both therapeutic (curing existing cancer) and medical (cancer prevention) radiation hormesis. Evidence is also provided demonstrating that exposure to environmental sparsely ionizing radiations, such as gamma rays, protect from cancer occurrence and the occurrence of other diseases via inducing adapted protection (environmental radiation hormesis). PMID:18648608
Magnetic Field Diagnostics and Spatio-Temporal Variability of the Solar Transition Region
NASA Astrophysics Data System (ADS)
Peter, H.
2013-12-01
Magnetic field diagnostics of the transition region from the chromosphere to the corona faces us with the problem that one has to apply extreme-ultraviolet (EUV) spectro-polarimetry. While for the coronal diagnostics techniques already exist in the form of infrared coronagraphy above the limb and radio observations on the disk, one has to investigate EUV observations for the transition region. However, so far the success of such observations has been limited, but various current projects aim to obtain spectro-polarimetric data in the extreme UV in the near future. Therefore it is timely to study the polarimetric signals we can expect from these observations through realistic forward modeling. We employ a 3D magneto-hydrodynamic (MHD) forward model of the solar corona and synthesize the Stokes I and Stokes V profiles of C iv (1548 Å). A signal well above 0.001 in Stokes V can be expected even if one integrates for several minutes to reach the required signal-to-noise ratio, and despite the rapidly changing intensity in the model (just as in observations). This variability of the intensity is often used as an argument against transition region magnetic diagnostics, which requires exposure times of minutes. However, the magnetic field is evolving much slower than the intensity, and therefore the degree of (circular) polarization remains rather constant when one integrates in time. Our study shows that it is possible to measure the transition region magnetic field if a polarimetric accuracy on the order of 0.001 can be reached, which we can expect from planned instrumentation.
Asay window: A new spall diagnostic
NASA Astrophysics Data System (ADS)
McCluskey, Craig W.; Wilke, Mark D.; Anderson, William W.; Byers, Mark E.; Holtkamp, David B.; Rigg, Paulo A.; Furnish, Michael D.; Romero, Vincent T.
2006-11-01
By changing from the metallic foil of the Asay foil diagnostic, which can detect ejecta from a shocked surface, to a lithium fluoride (LiF) or polymethyl methacrylate (PMMA) window, it is possible to detect multiple spall layers and interlayer rubble. Past experiments to demonstrate this diagnostic have used high explosives (HEs) to shock metals to produce multiple spall layers. Because the exact characteristics of HE-induced spall layers cannot be predetermined, two issues exist in the quantitative interpretation of the data. First, to what level of fidelity is the Asay window method capable of providing quantitative information about spall layers, possibly separated by rubble, and second, contingent on the first, can an analytic technique be developed to convert the data to a meaningful description of spall from a given experiment? In this article, we address the first issue. A layered projectile fired from a gas gun was used to test the new diagnostic's accuracy and repeatability. We impacted a LiF or PMMA window viewed by a velocity interferometer system for any reflector (VISAR) probe with a projectile consisting of four thin stainless steel disks spaced apart 200μm with either vacuum or polyethylene. The window/surface interface velocity measured with a VISAR probe was compared with calculations. The good agreement observed between the adjusted calculation and the measured data indicates that, in principle and given enough prior information, it is possible to use the Asay window data to model a density distribution from spalled material with simple hydrodynamic models and only simple adjustments to nominal predictions.
Diagnostic Teaching of the Language Arts.
ERIC Educational Resources Information Center
Burns, Paul C.
This book is based on the premise that learning can best be facilitated when the teacher takes a diagnostic view of the instructional process. To further this end, each chapter contains materials, models, and techniques designed to implement diagnostic teaching in the language arts program. The seven chapters are "Foundations for Diagnostic…
Dueholm, Margit; Lundorf, Erik; Olesen, Frede
2002-06-01
A literature review compared the diagnostic effectiveness and accuracy of transvaginal sonography (TVS) hysterosonographic examination (HSE), hysteroscopy (HY), and magnetic resonance imaging (MRI) in abnormalities of the uterine cavity and endometrium in premenopausal patients referred to surgery and women with abnormal uterine bleeding. The studies varied much in terms of patient selection, number of observers, blinding and experience of observers, and definition of abnormality criteria. The diagnostic effectiveness of the techniques reviewed varied: TVS only reached intermediate quality levels as a diagnostic tool for exclusion of uterine cavity abnormalities and no data support that MRI, TVS, HY, or HSE may exclude hyperplasia without concomitant endometrial sampling. HY and HSE were equally effective and apparently outperformed TVS, especially for identification of polyps. However, all techniques carried a significant number of false positive results. MRI does not satisfy current diagnostic demands for detection of endometrial abnormalities, but it is sufficiently accurate for submucous myoma (SM) evaluation. TVS, HSE, and HY carry much observer variation as opposed to MRI. In experienced hands TVS should be a first choice modality, but its precision and consistency fall short of current needs and it should therefore be supplemented by other techniques. HSE or HY performed by experienced clinicians should be used as supplements to TVS for exclusion of polyps. MRI can be recommended as the first choice modality for exact evaluation of SM uterine in-growth before advanced minimal invasive treatment of myomas. Clinicians should be aware that modern imaging techniques may yield highly idiosyncratic results when used by inexperienced staff, and efforts should be made to reduce such observer variation. Obstetricians & Gynecologists, Family Physicians. After completion of this article, the reader will be able to describe the diagnostic strengths and weaknesses of the various diagnostic tests in the evaluation of abnormal uterine bleeding and to compare the accuracy of each test to the others.
ERIC Educational Resources Information Center
Weaver, Sallie J.; Newman-Toker, David E.; Rosen, Michael A.
2012-01-01
Missed, delayed, or wrong diagnoses can have a severe impact on patients, providers, and the entire health care system. One mechanism implicated in such diagnostic errors is the deterioration of cognitive diagnostic skills that are used rarely or not at all over a prolonged period of time. Existing evidence regarding maintenance of effective…
New and improved tuberculosis diagnostics: evidence, policy, practice, and impact.
Pai, Madhukar; Minion, Jessica; Steingart, Karen; Ramsay, Andrew
2010-05-01
The aim is to summarize the evidence base for tuberculosis (TB) diagnostics, review recent policies on TB diagnostics, and discuss issues such as how evidence is translated into policy, limitations of the existing evidence base, and challenges involved in translating policies into impact. Case detection continues to be a major obstacle to global TB control. Fortunately, due to an unprecedented level of interest, funding, and activity, the new diagnostics pipeline for TB has rapidly expanded. There have been several new policies and guidelines on TB diagnostics. However, there are major gaps in the existing pipeline (e.g. lack of a point-of-care test) and the evidence base is predominantly made up of research studies of test accuracy. With the availability of new diagnostics and supporting policies, the next major step is translation of policy into practice. The impact of new tests will depend largely on the extent of their introduction and acceptance into the global public sector. This will itself depend in part on policy decisions by international technical agencies and national TB programs. With the engagement of all key stakeholders, we will need to translate evidence-based policies into epidemiological and public health impact.
Manna, Raffaele; Cauda, Roberto; Feriozzi, Sandro; Gambaro, Giovanni; Gasbarrini, Antonio; Lacombe, Didier; Livneh, Avi; Martini, Alberto; Ozdogan, Huri; Pisani, Antonio; Riccio, Eleonora; Verrecchia, Elena; Dagna, Lorenzo
2017-10-01
Fever of unknown origin (FUO) is a rather rare clinical syndrome representing a major diagnostic challenge. The occurrence of more than three febrile attacks with fever-free intervals of variable duration during 6 months of observation has recently been proposed as a subcategory of FUO, Recurrent FUO (RFUO). A substantial number of patients with RFUO have auto-inflammatory genetic fevers, but many patients remain undiagnosed. We hypothesize that this undiagnosed subgroup may be comprised of, at least in part, a number of rare genetic febrile diseases such as Fabry disease. We aimed to identify key features or potential diagnostic clues for Fabry disease as a model of rare genetic febrile diseases causing RFUO, and to develop diagnostic guidelines for RFUO, using Fabry disease as an example of inserting other rare diseases in the existing FUO algorithms. An international panel of specialists in recurrent fevers and rare diseases, including internists, infectious disease specialists, rheumatologists, gastroenterologists, nephrologists, and medical geneticists convened to review the existing diagnostic algorithms, and to suggest recommendations for arriving at accurate diagnoses on the basis of available literature and clinical experience. By combining specific features of rare diseases with other diagnostic considerations, guidelines have been designed to raise awareness and identify rare diseases among other causes of FUO. The proposed guidelines may be useful for the inclusion of rare diseases in the diagnostic algorithms for FUO. A wide spectrum of patients will be needed to validate the algorithm in different clinical settings.
Storey, Helen L.; Huang, Ying; Crudder, Chris; Golden, Allison; de los Santos, Tala; Hawkins, Kenneth
2015-01-01
Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS) can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates. PMID:26566275
Qu, Yongzhi; He, David; Yoon, Jae; Van Hecke, Brandon; Bechhoefer, Eric; Zhu, Junda
2014-01-01
In recent years, acoustic emission (AE) sensors and AE-based techniques have been developed and tested for gearbox fault diagnosis. In general, AE-based techniques require much higher sampling rates than vibration analysis-based techniques for gearbox fault diagnosis. Therefore, it is questionable whether an AE-based technique would give a better or at least the same performance as the vibration analysis-based techniques using the same sampling rate. To answer the question, this paper presents a comparative study for gearbox tooth damage level diagnostics using AE and vibration measurements, the first known attempt to compare the gearbox fault diagnostic performance of AE- and vibration analysis-based approaches using the same sampling rate. Partial tooth cut faults are seeded in a gearbox test rig and experimentally tested in a laboratory. Results have shown that the AE-based approach has the potential to differentiate gear tooth damage levels in comparison with the vibration-based approach. While vibration signals are easily affected by mechanical resonance, the AE signals show more stable performance. PMID:24424467
Tinmouth, Alan T.; McIntyre, Lauralynn A.; Fowler, Robert A.
2008-01-01
Anemia commonly affects critically ill patients. The causes are multifactorial and include acute blood loss, blood loss from diagnostic testing and blunted red blood cell production. Blood transfusions are frequently given to patients in intensive care units to treat low hemoglobin levels due to either acute blood loss or subacute anemia associated with critical illness. Although blood transfusion is a life-saving therapy, evidence suggests that it may be associated with an increased risk of morbidity and mortality. A number of blood conservation strategies exist that may mitigate anemia in hospital patients and limit the need for transfusion. These strategies include the use of hemostatic agents, hemoglobin substitutes and blood salvage techniques, the reduction of blood loss associated with diagnostic testing, the use of erythropoietin and the use of restrictive blood transfusion triggers. Strategies to reduce blood loss associated with diagnostic testing and the use of hemostatic agents and erythropoietin result in higher hemoglobin levels, but they have not been shown to reduce the need for blood transfusions or to improve clinical outcomes. Lowering the hemoglobin threshold at which blood is transfused will reduce the need for transfusions and is not associated with increased morbidity or mortality among most critically ill patients without active cardiac disease. Further research is needed to determine the potential roles for other blood conservation strategies. PMID:18166731
Osako, Tomo; Takeuchi, Kengo; Horii, Rie; Iwase, Takuji; Akiyama, Futoshi
2013-10-01
Secretory carcinoma (SC) is a rare histological type of breast cancer, and ETV6-NTRK3 gene fusion is highly specific to it. The differential diagnoses of SC include acinic cell carcinoma (ACCA) and cystic hypersecretory carcinoma (CHC), as well as invasive ductal carcinoma (IDC). For patients with these rare but distinctive histological subtypes, SC and its histopathological mimics should be differentiated from each other. However, differential markers have not yet been assessed systematically, and we aimed to identify and evaluate novel and existing markers. We reviewed 19 cases diagnosed initially as SC using integrated diagnostic techniques, including morphology, immunohistochemistry and molecular pathology, and validated promising markers in 445 breast cancers. We reclassified 19 formerly diagnosed 'SCs' into nine SCs, three ACCAs, three CHCs, three IDCs and one microglandular adenosis. We confirmed that ETV6-NTRK3 gene rearrangement and amylase positivity are good diagnostic markers for SC and ACCA, respectively. Vacuolar staining for adipophilin, positivity for α-lactalbumin and negativity for ETV6 rearrangement are diagnostic markers for CHC. In this study, we propose a panel of four markers (ETV6 rearrangement, amylase, α-lactalbumin and adipophilin) for distinguishing SC, ACCA, CHC and IDC. This simple but robust panel will serve pathologists well as a practical guide for reaching an appropriate diagnosis. © 2013 John Wiley & Sons Ltd.
Characterization of controlled bone defects using 2D and 3D ultrasound imaging techniques.
Parmar, Biren J; Longsine, Whitney; Sabonghy, Eric P; Han, Arum; Tasciotti, Ennio; Weiner, Bradley K; Ferrari, Mauro; Righetti, Raffaella
2010-08-21
Ultrasound is emerging as an attractive alternative modality to standard x-ray and CT methods for bone assessment applications. As of today, however, there is a lack of systematic studies that investigate the performance of diagnostic ultrasound techniques in bone imaging applications. This study aims at understanding the performance limitations of new ultrasound techniques for imaging bones in controlled experiments in vitro. Experiments are performed on samples of mammalian and non-mammalian bones with controlled defects with size ranging from 400 microm to 5 mm. Ultrasound findings are statistically compared with those obtained from the same samples using standard x-ray imaging modalities and optical microscopy. The results of this study demonstrate that it is feasible to use diagnostic ultrasound imaging techniques to assess sub-millimeter bone defects in real time and with high accuracy and precision. These results also demonstrate that ultrasound imaging techniques perform comparably better than x-ray imaging and optical imaging methods, in the assessment of a wide range of controlled defects both in mammalian and non-mammalian bones. In the future, ultrasound imaging techniques might provide a cost-effective, real-time, safe and portable diagnostic tool for bone imaging applications.
Wavelet-sparsity based regularization over time in the inverse problem of electrocardiography.
Cluitmans, Matthijs J M; Karel, Joël M H; Bonizzi, Pietro; Volders, Paul G A; Westra, Ronald L; Peeters, Ralf L M
2013-01-01
Noninvasive, detailed assessment of electrical cardiac activity at the level of the heart surface has the potential to revolutionize diagnostics and therapy of cardiac pathologies. Due to the requirement of noninvasiveness, body-surface potentials are measured and have to be projected back to the heart surface, yielding an ill-posed inverse problem. Ill-posedness ensures that there are non-unique solutions to this problem, resulting in a problem of choice. In the current paper, it is proposed to restrict this choice by requiring that the time series of reconstructed heart-surface potentials is sparse in the wavelet domain. A local search technique is introduced that pursues a sparse solution, using an orthogonal wavelet transform. Epicardial potentials reconstructed from this method are compared to those from existing methods, and validated with actual intracardiac recordings. The new technique improves the reconstructions in terms of smoothness and recovers physiologically meaningful details. Additionally, reconstruction of activation timing seems to be improved when pursuing sparsity of the reconstructed signals in the wavelet domain.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Iain S.; Wray, Craig P.; Guillot, Cyril
2003-08-01
In this report, we discuss the accuracy of flow hoods for residential applications, based on laboratory tests and field studies. The results indicate that commercially available hoods are often inadequate to measure flows in residential systems, and that there can be a wide range of performance between different flow hoods. The errors are due to poor calibrations, sensitivity of existing hoods to grille flow non-uniformities, and flow changes from added flow resistance. We also evaluated several simple techniques for measuring register airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics that are often as accuratemore » as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, organizations such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow hoods.« less
Nevalainen, Mika T; Repo, Jussi P; Pesola, Maija; Nyrhinen, Jukka P
2018-01-01
Osteonecrosis of the talus is a fairly rare condition. Many predisposing factors have been identified including previous trauma, use of corticosteroids, alcoholism, and smoking. As a gold standard, magnetic resonance imaging (MRI) is the most sensitive and specific diagnostic examination to detect osteonecrosis. While many treatment options for talar osteonecrosis exist, core decompression is suggested on young patients with good outcome results. More recently, intraosseous stem cell and platelet-rich plasma (PRP) injection has been added to the core decompression procedure. We report a successful treatment of early talar osteonecrosis ARCO I (Association Research Circulation Osseous) by core decompression combined with stem cell and PRP injection. On 3-month and 15-month follow-up, MRI showed complete resolution of the osteonecrotic changes together with clinical improvement. This modified technique is a viable treatment option for early talar osteonecrosis. Nevertheless, future prospects should include a study comparing this combined technique with plain core decompression.
van Dijken, Bart R J; van Laar, Peter Jan; Holtman, Gea A; van der Hoorn, Anouk
2017-10-01
Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. • Treatment response assessment in high-grade gliomas with anatomical MRI is unreliable • Novel advanced MRI techniques have been studied, but diagnostic accuracy is unknown • Meta-analysis demonstrates that advanced MRI showed higher diagnostic accuracy than anatomical MRI • Highest diagnostic accuracy for spectroscopy and perfusion MRI • Supports the incorporation of advanced MRI in high-grade glioma treatment response assessment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuznetsov, Yu L; Kalchenko, V V; Astaf'eva, N G
2014-08-31
The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)
Diagnostic techniques and treatments for internal disorders of Koi (Cyprinus carpio).
Saint-Erne, Nicholas
2010-09-01
The most common problems that occur in koi involve external pathogens and environmental conditions. Techniques for external fish examination and water quality analysis have been well described in the veterinary literature. However, there are also some internal disorders of koi, such as gas bladder abnormalities affecting the fish's buoyancy, neoplasia, egg binding (roe retention), and spinal disorders that can be diagnosed with common veterinary medical procedures. Diagnostic techniques along with available treatments for these disorders are presented in this article. Copyright 2010 Elsevier Inc. All rights reserved.
[Possibilities of sonographic image fusion: Current developments].
Jung, E M; Clevert, D-A
2015-11-01
For diagnostic and interventional procedures ultrasound (US) image fusion can be used as a complementary imaging technique. Image fusion has the advantage of real time imaging and can be combined with other cross-sectional imaging techniques. With the introduction of US contrast agents sonography and image fusion have gained more importance in the detection and characterization of liver lesions. Fusion of US images with computed tomography (CT) or magnetic resonance imaging (MRI) facilitates the diagnostics and postinterventional therapy control. In addition to the primary application of image fusion in the diagnosis and treatment of liver lesions, there are more useful indications for contrast-enhanced US (CEUS) in routine clinical diagnostic procedures, such as intraoperative US (IOUS), vascular imaging and diagnostics of other organs, such as the kidneys and prostate gland.
DIAGNOSTIC CRITERIA FOR PROLIFERATIVE THYROID LESIONS IN BONY FISHES
Thyroid proliferative lesions are rather common in bony fishes but disagreement exists in the fish pathology community concerning diagnostic criteria for hyperplastic versus neoplastic lesions. To simplify the diagnosis of proliferative thyroid lesions and to reduce confusion reg...
Rapid feedback of chemical vapor deposition growth mechanisms by operando X-ray diffraction
Martin, Aiden A.; Depond, Philip J.; Bagge-Hansen, Michael; ...
2018-03-14
An operando x-ray diffraction system is presented for elucidating optimal laser assisted chemical vapor deposition growth conditions. The technique is utilized to investigate deposition dynamics of boron-carbon materials using trimethyl borate precursor. Trimethyl borate exhibits vastly reduced toxicological and flammability hazards compared to existing precursors, but has previously not been applied to boron carbide growth. Crystalline boron-rich carbide material is produced in a narrow growth regime on addition of hydrogen during the growth phase at high temperature. Finally, the use of the operando x-ray diffraction system allows for the exploration of highly nonequilibrium conditions and rapid process control, which aremore » not possible using ex situ diagnostics.« less
In vivo THz sensing of the cornea of the eye
NASA Astrophysics Data System (ADS)
Ozheredov, Ilya; Prokopchuk, Mikhail; Mischenko, Mikhail; Safonova, Tatiana; Solyankin, Petr; Larichev, Andrey; Angeluts, Andrey; Balakin, Alexei; Shkurinov, Alexander
2018-05-01
Measurement of the absolute value of the humidity of the cornea of the human eye and its dynamics is of paramount importance for the preservation of eyesight. In the present paper we have demonstrated that terahertz technologies can be practically applied for quantitative measurement of the physiological dynamics of tear film and sensing of corneal tissue hydration. We suggest uses of the equipment for application in clinics and a method for absolute calibration of the values for measurement. The proposed method is fundamentally different from existing and currently available methods of ophthalmological diagnosis. This suggests that the developed technique may have high diagnostic significance and can be used in the study and treatment of several diseases of the ocular surface.
Rapid feedback of chemical vapor deposition growth mechanisms by operando X-ray diffraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Aiden A.; Depond, Philip J.; Bagge-Hansen, Michael
An operando x-ray diffraction system is presented for elucidating optimal laser assisted chemical vapor deposition growth conditions. The technique is utilized to investigate deposition dynamics of boron-carbon materials using trimethyl borate precursor. Trimethyl borate exhibits vastly reduced toxicological and flammability hazards compared to existing precursors, but has previously not been applied to boron carbide growth. Crystalline boron-rich carbide material is produced in a narrow growth regime on addition of hydrogen during the growth phase at high temperature. Finally, the use of the operando x-ray diffraction system allows for the exploration of highly nonequilibrium conditions and rapid process control, which aremore » not possible using ex situ diagnostics.« less
Jansen, A M; Moriearty, P L; Castro, B G; Deane, M P
1985-01-01
The use of an indirect fluorescent antibody test (IFAT) performed in a "sandwich" technique has demonstrated: (i) the usefulness of the test for the diagnosis of Trypanosoma cruzi infection in the opossum Didelphis marsupialis; (ii) the existence of differences in the serological response of the opossum, that were related to the parasite strain and were clearly evident during the follow-up of experimental infections in laboratory born specimens; (iii) that, despite a good correlation between serological and parasitological examinations, IFAT was the most sensitive diagnostic test used, followed by xenodiagnosis; and, (iv) that in general, the opossum D. marsupialis seems to be a good responder to T. cruzi antigens.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, R., E-mail: raspberry@lanl.gov; Danly, C.; Fatherley, V. E.
2015-12-15
The Neutron Imaging System (NIS) is an important diagnostic for understanding implosions of deuterium-tritium capsules at the National Ignition Facility. While the detectors for the existing system must be positioned 28 m from the source to produce sufficient imaging magnification and resolution, recent testing of a new short line of sight neutron imaging system has shown sufficient resolution to allow reconstruction of the source image with quality similar to that of the existing NIS on a 11.6 m line of sight. The new system used the existing pinhole aperture array and a stack of detectors composed of 2 mm thickmore » high-density polyethylene converter material followed by an image plate. In these detectors, neutrons enter the converter material and interact with protons, which recoil and deposit energy within the thin active layer of the image plate through ionization losses. The described system produces time-integrated images for all neutron energies passing through the pinhole. We present details of the measurement scheme for this novel technique to produce energy-integrated neutron images as well as source reconstruction results from recent experiments at NIF.« less
A Self-Diagnostic System for the M6 Accelerometer
NASA Technical Reports Server (NTRS)
Flanagan, Patrick M.; Lekki, John
2001-01-01
The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.
NASA Astrophysics Data System (ADS)
Wu, Yi; Modica, Vincent; Yu, Xilong; Li, Fei; Grisch, Frédéric
2018-01-01
The effects of optical diagnostic techniques on the accuracy of laminar flame speed measured from Bunsen flames were investigated. Laminar flame speed measurements were conducted for different fuel/air mixtures including CH4/air, acetone/air and kerosene (Jet A-1)/air in applying different optical diagnostic techniques, i.e. OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF. It is found that the OH* chemiluminescence imaging technique cannot directly derive the location of the outer edge of the fresh gases and it is necessary to correct the position of the OH* peak to guarantee the accuracy of the measurements. OH-PLIF and acetone/kerosene-PLIF respectively are able to measure the disappearance of the fresh gas contour and the appearance of the reaction zone. It shows that the aromatic-PLIF technique gives similar laminar flame speed values when compared with those obtained from corrected OH* chemiluminescence images. However, discrepancies were observed between the OH-PLIF and the aromatic-PLIF techniques, in that OH-PLIF slightly underestimates laminar flame speeds by up to 5%. The difference between the flame contours obtained from different optical techniques are further analysed and illustrated with 1D flame structure simulation using detailed kinetic mechanisms.
Antibody detection tests improve the sensitivity of tuberculosis diagnosis in cattle.
Casal, C; Infantes, J A; Risalde, M A; Díez-Guerrier, A; Domínguez, M; Moreno, I; Romero, B; de Juan, L; Sáez, J L; Juste, R; Gortázar, C; Domínguez, L; Bezos, J
2017-06-01
We evaluated the sensitivity (Se) of the single cervical intradermal tuberculin (SIT) test, two interferon-gamma (IFN-γ) assays and three different antibody detection techniques for bovine tuberculosis (bTB) diagnosis in 131 mixed beef breed cattle. The results of the diagnostic techniques performed over the whole herd, and over the animals confirmed as infected based on the presence of lesions compatible with the disease and/or M. bovis isolation were compared to determine apparent prevalence (AP) and Se. The Se of the SIT test (severe interpretation) was 63.7% (95% CI, 54.54-72.00), while the Se of the IFN-γ assays ranged between 60.2% and 92%. The proportion of infected cattle detected by the different antibody detection techniques ranged from 65.5% to 87.6%. Three of the antibody detection techniques yielded a significant higher (p<0.05) Se than that achieved with the official diagnostic techniques. In addition, the interpretation in parallel of cellular and antibody detection techniques reached the highest Se: 98.2% (95% CI, 93.78-99.51) suggesting that the use of diagnostic techniques detecting both cellular and humoral responses could be considered as an alternative in the control of bTB outbreaks in high prevalence settings. Copyright © 2017 Elsevier Ltd. All rights reserved.
Narrow band imaging combined with water immersion technique in the diagnosis of celiac disease.
Valitutti, Francesco; Oliva, Salvatore; Iorfida, Donatella; Aloi, Marina; Gatti, Silvia; Trovato, Chiara Maria; Montuori, Monica; Tiberti, Antonio; Cucchiara, Salvatore; Di Nardo, Giovanni
2014-12-01
The "multiple-biopsy" approach both in duodenum and bulb is the best strategy to confirm the diagnosis of celiac disease; however, this increases the invasiveness of the procedure itself and is time-consuming. To evaluate the diagnostic yield of a single biopsy guided by narrow-band imaging combined with water immersion technique in paediatric patients. Prospective assessment of the diagnostic accuracy of narrow-band imaging/water immersion technique-driven biopsy approach versus standard protocol in suspected celiac disease. The experimental approach correctly diagnosed 35/40 children with celiac disease, with an overall diagnostic sensitivity of 87.5% (95% CI: 77.3-97.7). An altered pattern of narrow-band imaging/water immersion technique endoscopic visualization was significantly associated with villous atrophy at guided biopsy (Spearman Rho 0.637, p<0.001). Concordance of narrow-band imaging/water immersion technique endoscopic assessments was high between two operators (K: 0.884). The experimental protocol was highly timesaving compared to the standard protocol. An altered narrow-band imaging/water immersion technique pattern coupled with high anti-transglutaminase antibodies could allow a single guided biopsy to diagnose celiac disease. When no altered mucosal pattern is visible even by narrow-band imaging/water immersion technique, multiple bulbar and duodenal biopsies should be obtained. Copyright © 2014. Published by Elsevier Ltd.
Thomson scattering diagnostic systems in ITER
NASA Astrophysics Data System (ADS)
Bassan, M.; Andrew, P.; Kurskiev, G.; Mukhin, E.; Hatae, T.; Vayakis, G.; Yatsuka, E.; Walsh, M.
2016-01-01
Thomson scattering (TS) is a proven diagnostic technique that will be implemented in ITER in three independent systems. The Edge TS will measure electron temperature Te and electron density ne profiles at high resolution in the region with r/a>0.8 (with a the minor radius). The Core TS will cover the region r/a<0.85 and shall be able to measure electron temperatures up to 40 keV . The Divertor TS will observe a segment of the divertor plasma more than 700 mm long and is designed to detect Te as low as 0.3 eV . The Edge and Core systems are primary contributors to Te and ne profiles. Both are installed in equatorial port 10 and very close together with the toroidal distance between the two laser beams of less than 600 mm at the first wall (~ 6° toroidal separation), a characteristic that should allow to reliably match the two profiles in the region 0.8
Ambient Ionization Mass Spectrometry for Cancer Diagnosis and Surgical Margin Evaluation
Ifa, Demian R.; Eberlin, Livia S.
2017-01-01
Background There is a clinical need for new technologies that would enable rapid disease diagnosis based on diagnostic molecular signatures. Ambient ionization mass spectrometry has revolutionized the means by which molecular information can be obtained from tissue samples in real time and with minimal sample pretreatment. New developments in ambient ionization techniques applied to clinical research suggest that ambient ionization mass spectrometry will soon become a routine medical tool for tissue diagnosis. Content This review summarizes the main developments in ambient ionization techniques applied to tissue analysis, with focus on desorption electrospray ionization mass spectrometry, probe electrospray ionization, touch spray, and rapid evaporative ionization mass spectrometry. We describe their applications to human cancer research and surgical margin evaluation, highlighting integrated approaches tested for ex vivo and in vivo human cancer tissue analysis. We also discuss the challenges for clinical implementation of these tools and offer perspectives on the future of the field. Summary A variety of studies have showcased the value of ambient ionization mass spectrometry for rapid and accurate cancer diagnosis. Small molecules have been identified as potential diagnostic biomarkers, including metabolites, fatty acids, and glycerophospholipids. Statistical analysis allows tissue discrimination with high accuracy rates (>95%) being common. This young field has challenges to overcome before it is ready to be broadly accepted as a medical tool for cancer diagnosis. Growing research in new, integrated ambient ionization mass spectrometry technologies and the ongoing improvements in the existing tools make this field very promising for future translation into the clinic. PMID:26555455
Computer aided diagnosis of diabetic peripheral neuropathy
NASA Astrophysics Data System (ADS)
Chekh, Viktor; Soliz, Peter; McGrew, Elizabeth; Barriga, Simon; Burge, Mark; Luan, Shuang
2014-03-01
Diabetic peripheral neuropathy (DPN) refers to the nerve damage that can occur in diabetes patients. It most often affects the extremities, such as the feet, and can lead to peripheral vascular disease, deformity, infection, ulceration, and even amputation. The key to managing diabetic foot is prevention and early detection. Unfortunately, current existing diagnostic techniques are mostly based on patient sensations and exhibit significant inter- and intra-observer differences. We have developed a computer aided diagnostic (CAD) system for diabetic peripheral neuropathy. The thermal response of the feet of diabetic patients following cold stimulus is captured using an infrared camera. The plantar foot in the images from a thermal video are segmented and registered for tracking points or specific regions. The temperature recovery of each point on the plantar foot is extracted using our bio-thermal model and analyzed. The regions that exhibit abnormal ability to recover are automatically identified to aid the physicians to recognize problematic areas. The key to our CAD system is the segmentation of infrared video. The main challenges for segmenting infrared video compared to normal digital video are (1) as the foot warms up, it also warms up the surrounding, creating an ever changing contrast; and (2) there may be significant motion during imaging. To overcome this, a hybrid segmentation algorithm was developed based on a number of techniques such as continuous max-flow, model based segmentation, shape preservation, convex hull, and temperature normalization. Verifications of the automatic segmentation and registration using manual segmentation and markers show good agreement.
Diagnosis of fetal syndromes by three- and four-dimensional ultrasound: is there any improvement?
Barišić, Lara Spalldi; Stanojević, Milan; Kurjak, Asim; Porović, Selma; Gaber, Ghalia
2017-08-28
With all of our present knowledge, high technology diagnostic equipment, electronic databases and other available supporting resources, detection of fetal syndromes is still a challenge for healthcare providers in prenatal as well as in the postnatal period. Prenatal diagnosis of fetal syndromes is not straightforward, and it is a difficult puzzle that needs to be assembled and solved. Detection of one anomaly should always raise a suspicion of the existence of more anomalies, and can be a trigger to investigate further and raise awareness of possible syndromes. Highly specialized software systems for three- and four-dimensional ultrasound (3D/4D US) enabled detailed depiction of fetal anatomy and assessment of the dynamics of fetal structural and functional development in real time. With recent advances in 3D/4D US technology, antenatal diagnosis of fetal anomalies and syndromes shifted from the 2nd to the 1st trimester of pregnancy. It is questionable what can and should be done after the prenatal diagnosis of fetal syndrome. The 3D and 4D US techniques improved detection accuracy of fetal abnormalities and syndromes from early pregnancy onwards. It is not easy to make prenatal diagnosis of fetal syndromes, so tools which help like online integrated databases are needed to increase diagnostic precision. The aim of this paper is to present the possibilities of different US techniques in the detection of some fetal syndromes prenatally.
NASA Astrophysics Data System (ADS)
Bashkov, O. V.; Bryansky, A. A.; Panin, S. V.; Zaikov, V. I.
2016-11-01
Strength properties of the glass fiber reinforced polymers (GFRP) fabricated by vacuum and vacuum autoclave molding techniques were analyzed. Measurements of porosity of the GFRP parts manufactured by various molding techniques were conducted with the help of optical microscopy. On the basis of experimental data obtained by means of acoustic emission hardware/software setup, the technique for running diagnostics and forecasting the bearing capacity of polymeric composite materials based on the result of three-point bending tests has been developed. The operation principle of the technique is underlined by the evaluation of the power function index change which takes place on the dependence of the total acoustic emission counts versus the loading stress.
Sow, Doudou; Dieng, Yémou; Haouchine, Djamal; Niang, Khadim; Niang, Thiane; Sylla, Khadime; Tine, Roger Clément; Ndiaye, Magatte; Ndiaye, Jean Louis; Faye, Babacar; Faye, Omar; Gaye, Oumar; Dieng, Thérèse; Izri, Arezki
2017-09-01
In the context of controlling intestinal parasites, accurate diagnosis is essential. Our objective was to evaluate the performance of new diagnostic kits compared to conventional microscopic methods in identifying intestinal parasites. Faeces collected in rural area in Senegal were subjected to several detection techniques. Thus, the sensitivity, specificity, positive and negative predictive values of new diagnostic techniques were compared to conventional merthiolate-iodine-formalin, conventional Bailenger and modified Ritchie. Furthermore, the kappa coefficient was calculated to evaluate the correlation between the new kit and those of modified Ritchie. Out of the 117 patients examined, 102 presented with a parasite, or prevalence of 87.1%. The Fumouze techniques proved to be as effective as the conventional methods in detecting flagellates and helminths with sensitivities ranging from 97 to 100%. However, conventional techniques were slightly more sensitive in identifying Endolimax nana and Blastocystis hominis . The correlation was nearly perfect (k = 0.83 and 1), respectively between Bailenger Fumouze, Iodesine Fumouze and modified Ritchie in identifying helminths while it was just acceptable (k = 0.27 and 0.28) in identifying B. hominis . The modified Ritchie technique routinely used in our laboratory remains a good diagnostic tool. However, the use of kit techniques was interesting when reading the pellet after concentration and the Colour KOP staining was a considerable contribution to the diagnosis of the vegetative forms. Therefore, it would be interesting to determine the cost of a stool test using Fumouze kit techniques to provide the most cost effective way.
Diagnostic value of imaging in infective endocarditis: a systematic review.
Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu
2017-01-01
Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review to critically appraise the evidence for the diagnostic performance of these imaging modalities, according to PRISMA and GRADE criteria. We searched PubMed, Embase, and Cochrane databases. 31 studies were included that presented original data on the performance of electrocardiogram (ECG)-gated multidetector CT angiography (MDCTA), ECG-gated MRI, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET/CT, and leucocyte scintigraphy in diagnosis of native valve endocarditis, intracardiac prosthetic material-related infection, and extracardiac foci in adults. We consistently found positive albeit weak evidence for the diagnostic benefit of 18 F-FDG PET/CT and MDCTA. We conclude that additional imaging techniques should be considered if infective endocarditis is suspected. We propose an evidence-based diagnostic work-up for infective endocarditis including these non-invasive techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.
Applications of the oral scraped (exfoliative) cytology in oral cancer and precancer.
Acha, Amelia; Ruesga, María T; Rodríguez, María J; Martínez de Pancorbo, María A; Aguirre, José M
2005-01-01
Scraped (exfoliative) cytology is a simple and harmless procedure, which has been a controversial technique according to its real validity in oral pathology. Lately it has re-emerged due to its application in oral precancer and cancer as a diagnostic and predictive method as well as for monitoring patients. New diagnostic techniques have been developed, such as "brush biopsy" and multiple molecular studies using the cells collected. In this review we are going to analyse the more novel aspects related with the applications of the scraped or exfoliative cytology in oral precancerous and cancerous pathology, specially focusing on molecular studies and their diagnostic and prognostic implications.
Role of electromagnetic navigational bronchoscopy in pulmonary nodule management
Dahagam, Chanukya; Breen, David P.; Sarkar, Saiyad
2016-01-01
The incidence of pulmonary nodules and lung cancer is rising. Some of this increase in incidence is due to improved pick up by newer imaging modalities. However, the goal is to diagnose these lesion, many of which are located in the periphery, by safe and relatively non-invasive methods. This has led to the emergence of numerous techniques such as electromagnetic navigational bronchoscopy (ENB). Current evidence supports a role for these techniques in the diagnostic pathway. However, numerous factor influence the diagnostic accuracy. Thus despite significant advances, more research needs to be undertaken to further improve the currently available diagnostic technologies. PMID:27606080
The role of diagnostic ultrasound as a new diagnostic aid in oral and maxillofacial surgery
Venkataraman, Siva Subramaniyam; Aravind, Ramraj Jayabalan; Kavin, Thangavelu
2012-01-01
Only very few studies have been done in the past to evaluate the usefulness and limitations of ultrasonography in oral and maxillofacial surgery. This study, though in an embryonic stage, has been done to bring this technique to limelight and to put forth the importance of its use and limitations in the branch of oral surgery. The purpose of this study was to investigate and study the characteristic pattern of the oral tissues on gray scale ultrasonography and to assess the practical applicability of this new diagnostic technique in diagnosing various tissue pathologies in the field of oral and maxillofacial surgery. PMID:23066231
Diagnostic imaging in bovine orthopedics.
Kofler, Johann; Geissbühler, Urs; Steiner, Adrian
2014-03-01
Although a radiographic unit is not standard equipment for bovine practitioners in hospital or field situations, ultrasound machines with 7.5-MHz linear transducers have been used in bovine reproduction for many years, and are eminently suitable for evaluation of orthopedic disorders. The goal of this article is to encourage veterinarians to use radiology and ultrasonography for the evaluation of bovine orthopedic disorders. These diagnostic imaging techniques improve the likelihood of a definitive diagnosis in every bovine patient but especially in highly valuable cattle, whose owners demand increasingly more diagnostic and surgical interventions that require high-level specialized techniques. Copyright © 2014 Elsevier Inc. All rights reserved.
[Immunodiagnostic methods in lupus erythematosus disseminatus].
Storch, H; Schwenke, H; Helbig, W
1975-12-01
In 27 patients with lupus erythematodes diseminatus the determinations of the LE-cells according to the macromethod (Zimmer and Hargraves) and the micromethod (Mudrik and co-workers) were compared with the demonstration of antinuclear factors according to the indirect immunofluorescence and immune enzyme technique. The sensitiveness of the two last-mentioned immunomorphological methods is somewhat larger. In these cases the size of the titre of the antinuclear factor almost always correlates positively with the number of the LE-cells. For the purpose of the initial diagnostics and the judgment of the course a morphological method cannot be renounced, since in the acute episode a high consumption of the antinuclear factor the immunological methods negatively correlate with the number of the LE-cells. The immune enzyme technique is to be recommended on account of the smaller expenditure, permanence of the preparations and high sensitiveness as alternative method of the immunofluorescence technique. In the micromethod the large variation is opposite to the advantage of the slight quantity of blood and to an always existing evaluability. Investigations of the lymphocytes of patients with lupus erythematodes disseminatus by means of the lymphocyte transformation test and the determination of the B-cells with the help of the direct immune peroxidase technique refer to the close pathogenetic connections of cellular and humoral immune reactions in this disease.
Molecular diagnostics of periodontitis.
Korona-Głowniak, Izabela; Siwiec, Radosław; Berger, Marcin; Malm, Anna; Szymańska, Jolanta
2017-01-28
The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host's health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridization) come increasingly into use. On the basis of a literature review, the following methods are presented: polymerase chain reaction (PCR), real-time polymerase chain reaction (real-time PCR), 16S rRNA-encoding gene sequencing, checkerboard and reverse-capture checkerboard hybridization, microarrays, denaturing gradient gel electrophoresis (DGGE), temperature gradient gel electrophoresis (TGGE), as well as terminal restriction fragment length polymorphism (TRFLP) and next generation sequencing (NGS). The advantages and drawbacks of each method in the examination of periopathogens are indicated. The techniques listed above allow fast detection of even small quantities of pathogen present in diagnostic material and prove particularly useful to detect microorganisms that are difficult or impossible to grow in a laboratory.
18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.
Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S
2017-02-01
This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.
Depressive disorders co-existing with Addison-Biermer anemia - case report.
Just, Mark Jean; Kozakiewicz, Mariusz
2015-01-01
Anemia is a disease that can co-exist with depression, other mental disorders, or somatic diseases. Anemia can imitate symptoms of depression, while depression symptoms can mask concurring symptoms of anemia. I am presenting a case of a 48-year-old woman with Addison-Biermer anemia, with co-existing mood disorders. The clinical analysis of the presented patient's history indicates diagnostic problems and a need for a detailed analysis of drug-related complications that occurred during previous treatment, eg, in the form of neuroleptic malignant syndrome. The presented case report contains valuable guidelines that can be of assistance in diagnostics and treatment of patients treated for mental disorders, who are also diagnosed with somatic diseases.
NASA Astrophysics Data System (ADS)
Restaino, Stephen M.; White, Ian M.
2017-03-01
Surface Enhanced Raman spectroscopy (SERS) provides significant improvements over conventional methods for single and multianalyte quantification. Specifically, the spectroscopic fingerprint provided by Raman scattering allows for a direct multiplexing potential far beyond that of fluorescence and colorimetry. Additionally, SERS generates a comparatively low financial and spatial footprint compared with common fluorescence based systems. Despite the advantages of SERS, it has remained largely an academic pursuit. In the field of biosensing, techniques to apply SERS to molecular diagnostics are constantly under development but, most often, assay protocols are redesigned around the use of SERS as a quantification method and ultimately complicate existing protocols. Our group has sought to rethink common SERS methodologies in order to produce translational technologies capable of allowing SERS to compete in the evolving, yet often inflexible biosensing field. This work will discuss the development of two techniques for quantification of microRNA, a promising biomarker for homeostatic and disease conditions ranging from cancer to HIV. First, an inkjet-printed paper SERS sensor has been developed to allow on-demand production of a customizable and multiplexable single-step lateral flow assay for miRNA quantification. Second, as miRNA concentrations commonly exist in relatively low concentrations, amplification methods (e.g. PCR) are therefore required to facilitate quantification. This work presents a novel miRNA assay alongside a novel technique for quantification of nuclease driven nucleic acid amplification strategies that will allow SERS to be used directly with common amplification strategies for quantification of miRNA and other nucleic acid biomarkers.
Pulmonary Infiltrates in Immunosuppressed Patients: Analysis of a Diagnostic Protocol
Danés, Cristina; González-Martín, Julián; Pumarola, Tomàs; Rañó, Ana; Benito, Natividad; Torres, Antoni; Moreno, Asunción; Rovira, Montserrat; Puig de la Bellacasa, Jorge
2002-01-01
A diagnostic protocol was started to study the etiology of pulmonary infiltrates in immunosuppressed patients. The diagnostic yields of the different techniques were analyzed, with special emphasis on the importance of the sample quality and the role of rapid techniques in the diagnostic strategy. In total, 241 patients with newly developed pulmonary infiltrates within a period of 19 months were included. Noninvasive or invasive evaluation was performed according to the characteristics of the infiltrates. Diagnosis was achieved in 202 patients (84%); 173 patients (72%) had pneumonia, and specific etiologic agents were found in 114 (66%). Bronchoaspirate and bronchoalveolar lavage showed the highest yields, either on global analysis (23 of 35 specimens [66%] and 70 of 134 specimens [52%], respectively) or on analysis of each type of pneumonia. A tendency toward better results with optimal-quality samples was observed, and a statistically significant difference was found in sputum bacterial culture. Rapid diagnostic tests yielded results in 71 of 114 (62.2%) diagnoses of etiological pneumonia. PMID:12037077
Erlandsson, Lena; Rosenstierne, Maiken W.; McLoughlin, Kevin; Jaing, Crystal; Fomsgaard, Anders
2011-01-01
A common technique used for sensitive and specific diagnostic virus detection in clinical samples is PCR that can identify one or several viruses in one assay. However, a diagnostic microarray containing probes for all human pathogens could replace hundreds of individual PCR-reactions and remove the need for a clear clinical hypothesis regarding a suspected pathogen. We have established such a diagnostic platform for random amplification and subsequent microarray identification of viral pathogens in clinical samples. We show that Phi29 polymerase-amplification of a diverse set of clinical samples generates enough viral material for successful identification by the Microbial Detection Array, demonstrating the potential of the microarray technique for broad-spectrum pathogen detection. We conclude that this method detects both DNA and RNA virus, present in the same sample, as well as differentiates between different virus subtypes. We propose this assay for diagnostic analysis of viruses in clinical samples. PMID:21853040
Lianidou, Evi; Ahmad-Nejad, Parviz; Ferreira-Gonzalez, Andrea; Izuhara, Kenji; Cremonesi, Laura; Schroeder, Maria-Eugenia; Richter, Karin; Ferrari, Maurizio; Neumaier, Michael
2014-09-25
Molecular techniques are becoming commonplace in the diagnostic laboratory. Their applications influence all major phases of laboratory medicine including predisposition/genetic risk, primary diagnosis, therapy stratification and prognosis. Readily available laboratory hardware and wetware (i.e. consumables and reagents) foster rapid dissemination to countries that are just establishing molecular testing programs. Appropriate skill levels extending beyond the technical procedure are required for analytical and diagnostic proficiency that is mandatory in molecular genetic testing. An international committee (C-CMBC) of the International Federation for Clinical Chemistry (IFCC) was established to disseminate skills in molecular genetic testing in member countries embarking on the respective techniques. We report the ten-year experience with different teaching and workshop formats for beginners in molecular diagnostics. Copyright © 2014 Elsevier B.V. All rights reserved.
The Diagnosticity of Color for Emotional Objects
McMenamin, Brenton W.; Radue, Jasmine; Trask, Joanna; Huskamp, Kristin; Kersten, Daniel; Marsolek, Chad J.
2012-01-01
Object classification can be facilitated if simple diagnostic features can be used to determine class membership. Previous studies have found that simple shapes may be diagnostic for emotional content and automatically alter the allocation of visual attention. In the present study, we analyzed whether color is diagnostic of emotional content and tested whether emotionally diagnostic hues alter the allocation of visual attention. Reddish-yellow hues are more common in (i.e., diagnostic of) emotional images, particularly images with positive emotional content. An exogenous cueing paradigm was employed to test whether these diagnostic hues orient attention differently from other hues due to the emotional diagnosticity. In two experiments, we found that participants allocated attention differently to diagnostic hues than to non-diagnostic hues, in a pattern indicating a broadening of spatial attention when cued with diagnostic hues. Moreover, the attentional broadening effect was predicted by self-reported measures of affective style, linking the behavioral effect to emotional processes. These results confirm the existence and use of diagnostic features for the rapid detection of emotional content. PMID:24659831
Govindarajan, S.; Sharath, B. N.; Tripathy, J. P.; Chinnakali, P.; Kumar, A. M. V.; Muthaiah, M.; Vivekananda, K.; Paulraj, A. K.; Roy, G.
2015-01-01
Setting: The Revised National Tuberculosis Control Programme, Puducherry, India, which has facilities for molecular diagnostic technique. Objective: To determine pre-diagnostic and pre-treatment attrition among presumptive multidrug-resistant tuberculosis (MDR-TB) patients and reasons for attrition. Methods: In this mixed-methods study, the quantitative component consisted of retrospective cohort analysis through record review of all presumptive MDR-TB patients recorded between October 2012 and September 2013. The qualitative component included in-depth interviews with key informants involved in programmatic management of drug-resistant tuberculosis services. Results: Of 341 eligible presumptive MDR-TB patients, pre-diagnostic and pre-treatment attrition was respectively 45.5% (155/341) and 29% (2/7). Patients with extra-pulmonary TB (RR = 2.3), those with human immuno-deficiency and TB co-infection (RR = 1.7), those registered during October–December 2012 (RR = 1.3) and those identified from primary/secondary health centres (RR = 1.8) were less likely to be tested. Themes that emerged during the analysis of the qualitative data were ‘lack of a systematic mechanism to track referrals for culture and drug susceptibility testing’, ‘absence of courier service to transport sputum’, ‘lack of knowledge and ownership among staff of general health system’, ‘shortage of diagnostic kits’ and ‘patient non-adherence’. Conclusion: Despite the introduction of molecular diagnostic techniques, operational issues in MDR-TB screening remain a concern and require urgent attention. PMID:26400385
Severson, Carl A; Pendharkar, Sachin R; Ronksley, Paul E; Tsai, Willis H
2015-01-01
To assess the ability of electronic health data and existing screening tools to identify clinically significant obstructive sleep apnea (OSA), as defined by symptomatic or severe OSA. The present retrospective cohort study of 1041 patients referred for sleep diagnostic testing was undertaken at a tertiary sleep centre in Calgary, Alberta. A diagnosis of clinically significant OSA or an alternative sleep diagnosis was assigned to each patient through blinded independent chart review by two sleep physicians. Predictive variables were identified from online questionnaire data, and diagnostic algorithms were developed. The performance of electronically derived algorithms for identifying patients with clinically significant OSA was determined. Diagnostic performance of these algorithms was compared with versions of the STOP-Bang questionnaire and adjusted neck circumference score (ANC) derived from electronic data. Electronic questionnaire data were highly sensitive (>95%) at identifying clinically significant OSA, but not specific. Sleep diagnostic testing-determined respiratory disturbance index was very specific (specificity ≥95%) for clinically relevant disease, but not sensitive (<35%). Derived algorithms had similar accuracy to the STOP-Bang or ANC, but required fewer questions and calculations. These data suggest that a two-step process using a small number of clinical variables (maximizing sensitivity) and objective diagnostic testing (maximizing specificity) is required to identify clinically significant OSA. When used in an online setting, simple algorithms can identify clinically relevant OSA with similar performance to existing decision rules such as the STOP-Bang or ANC.
Three-Dimensional Printing Articular Cartilage: Recapitulating the Complexity of Native Tissue.
Guo, Ting; Lembong, Josephine; Zhang, Lijie Grace; Fisher, John P
2017-06-01
In the past few decades, the field of tissue engineering combined with rapid prototyping (RP) techniques has been successful in creating biological substitutes that mimic tissues. Its applications in regenerative medicine have drawn efforts in research from various scientific fields, diagnostics, and clinical translation to therapies. While some areas of therapeutics are well developed, such as skin replacement, many others such as cartilage repair can still greatly benefit from tissue engineering and RP due to the low success and/or inefficiency of current existing, often surgical treatments. Through fabrication of complex scaffolds and development of advanced materials, RP provides a new avenue for cartilage repair. Computer-aided design and three-dimensional (3D) printing allow the fabrication of modeled cartilage scaffolds for repair and regeneration of damaged cartilage tissues. Specifically, the various processes of 3D printing will be discussed in details, both cellular and acellular techniques, covering the different materials, geometries, and operational printing conditions for the development of tissue-engineered articular cartilage. Finally, we conclude with some insights on future applications and challenges related to this technology, especially using 3D printing techniques to recapitulate the complexity of native structure for advanced cartilage regeneration.
Evaluating the Surveillance System for Spotted Fever in Brazil Using Machine-Learning Techniques.
Lopez, Diego Montenegro; de Mello, Flávio Luis; Giordano Dias, Cristina Maria; Almeida, Paula; Araújo, Milton; Magalhães, Monica Avelar; Gazeta, Gilberto Salles; Brasil, Reginaldo Peçanha
2017-01-01
This work analyses the performance of the Brazilian spotted fever (SF) surveillance system in diagnosing and confirming suspected cases in the state of Rio de Janeiro (RJ), from 2007 to 2016 (July) using machine-learning techniques. Of the 890 cases reported to the Disease Notification Information System (SINAN), 11.7% were confirmed as SF, 2.9% as dengue, 1.6% as leptospirosis, and 0.7% as tick bite allergy, with the remainder being diagnosed as other categories (10.5%) or unspecified (72.7%). This study confirms the existence of obstacles in the diagnostic classification of suspected cases of SF by clinical signs and symptoms. Unlike man-capybara contact (1.7% of cases), man-tick contact (71.2%) represents an important risk indicator for SF. The analysis of decision trees highlights some clinical symptoms related to SF patient death or cure, such as: respiratory distress, convulsion, shock, petechiae, coma, icterus, and diarrhea. Moreover, cartographic techniques document patient transit between RJ and bordering states and within RJ itself. This work recommends some changes to SINAN that would provide a greater understanding of the dynamics of SF and serve as a model for other endemic areas in Brazil.
Evaluating the Surveillance System for Spotted Fever in Brazil Using Machine-Learning Techniques
Lopez, Diego Montenegro; de Mello, Flávio Luis; Giordano Dias, Cristina Maria; Almeida, Paula; Araújo, Milton; Magalhães, Monica Avelar; Gazeta, Gilberto Salles; Brasil, Reginaldo Peçanha
2017-01-01
This work analyses the performance of the Brazilian spotted fever (SF) surveillance system in diagnosing and confirming suspected cases in the state of Rio de Janeiro (RJ), from 2007 to 2016 (July) using machine-learning techniques. Of the 890 cases reported to the Disease Notification Information System (SINAN), 11.7% were confirmed as SF, 2.9% as dengue, 1.6% as leptospirosis, and 0.7% as tick bite allergy, with the remainder being diagnosed as other categories (10.5%) or unspecified (72.7%). This study confirms the existence of obstacles in the diagnostic classification of suspected cases of SF by clinical signs and symptoms. Unlike man–capybara contact (1.7% of cases), man–tick contact (71.2%) represents an important risk indicator for SF. The analysis of decision trees highlights some clinical symptoms related to SF patient death or cure, such as: respiratory distress, convulsion, shock, petechiae, coma, icterus, and diarrhea. Moreover, cartographic techniques document patient transit between RJ and bordering states and within RJ itself. This work recommends some changes to SINAN that would provide a greater understanding of the dynamics of SF and serve as a model for other endemic areas in Brazil. PMID:29250519
An image filtering technique for SPIDER visible tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fonnesu, N., E-mail: nicola.fonnesu@igi.cnr.it; Agostini, M.; Brombin, M.
2014-02-15
The tomographic diagnostic developed for the beam generated in the SPIDER facility (100 keV, 50 A prototype negative ion source of ITER neutral beam injector) will characterize the two-dimensional particle density distribution of the beam. The simulations described in the paper show that instrumental noise has a large influence on the maximum achievable resolution of the diagnostic. To reduce its impact on beam pattern reconstruction, a filtering technique has been adapted and implemented in the tomography code. This technique is applied to the simulated tomographic reconstruction of the SPIDER beam, and the main results are reported.
Nuclear imaging and radiation therapy in canine and feline thyroid disease.
Feeney, Daniel A; Anderson, Kari L
2007-07-01
The indications, techniques, and expectations for radionuclide diagnostic studies on canine and feline thyroid glands are presented. In addition, the considerations surrounding radioiodine or external beam radiotherapy for benign and malignant thyroid disease are reviewed. The intent of this article is to familiarize primary care veterinarians with the utility of and outcome of the ionizing radiation-based diagnostic and therapeutic techniques for assessing and treating canine and feline thyroid disease.
Applications of digital processing for noise removal from plasma diagnostics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kane, R.J.; Candy, J.V.; Casper, T.A.
1985-11-11
The use of digital signal techniques for removal of noise components present in plasma diagnostic signals is discussed, particularly with reference to diamagnetic loop signals. These signals contain noise due to power supply ripple in addition to plasma characteristics. The application of noise canceling techniques, such as adaptive noise canceling and model-based estimation, will be discussed. The use of computer codes such as SIG is described. 19 refs., 5 figs.
Turner, Hugo C; Bettis, Alison A; Dunn, Julia C; Whitton, Jane M; Hollingsworth, T Déirdre; Fleming, Fiona M; Anderson, Roy M
2017-06-01
While the need for more sensitive diagnostics for intestinal helminths is well known, the cost of developing and implementing new tests is considered relatively high compared to the Kato-Katz technique. Here, we review the reported costs of performing the Kato-Katz technique. We also outline several economic arguments we believe highlight the need for further investment in alternative diagnostics, and considerations that should be made when comparing their costs. In our opinion, we highlight that, without new diagnostic methods, it will be difficult for policy makers to make the most cost-effective decisions and that the potentially higher unit costs of new methods can be outweighed by the long-term programmatic benefits they have (such as the ability to detect the interruption of transmission). Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Machine learning, medical diagnosis, and biomedical engineering research - commentary.
Foster, Kenneth R; Koprowski, Robert; Skufca, Joseph D
2014-07-05
A large number of papers are appearing in the biomedical engineering literature that describe the use of machine learning techniques to develop classifiers for detection or diagnosis of disease. However, the usefulness of this approach in developing clinically validated diagnostic techniques so far has been limited and the methods are prone to overfitting and other problems which may not be immediately apparent to the investigators. This commentary is intended to help sensitize investigators as well as readers and reviewers of papers to some potential pitfalls in the development of classifiers, and suggests steps that researchers can take to help avoid these problems. Building classifiers should be viewed not simply as an add-on statistical analysis, but as part and parcel of the experimental process. Validation of classifiers for diagnostic applications should be considered as part of a much larger process of establishing the clinical validity of the diagnostic technique.
A Clinicopathological Study of Various Oral Cancer Diagnostic Techniques
Ulaganathan, G.; Mohamed Niazi, K. Thanvir; Srinivasan, Soundarya; Balaji, V. R.; Manikandan, D.; Hameed, K. A. Shahul; Banumathi, A.
2017-01-01
Oral cancer is one of the most commonly occurring malignant tumors in the head and neck regions with high incident rate and mortality rate in the developed countries than in the developing countries. Generally, the survival rate of cancer patients may increase when diagnosed at early stage, followed by prompt treatment and therapy. Recently, cancer diagnosis and therapy design for a specific cancer patient have been performed with the advanced computer-aided techniques. The responses of the cancer therapy could be continuously monitored to ensure the effectiveness of the treatment process that hardly requires diagnostic result as quick as possible to improve the quality and patient care. This paper gives an overview of oral cancer occurrence, different types, and various diagnostic techniques. In addition, a brief introduction is given to various stages of immunoanalysis including tissue image preparation, whole slide imaging, and microscopic image analysis. PMID:29284926
Sinenian, N; Manuel, M J-E; Zylstra, A B; Rosenberg, M; Waugh, C J; Rinderknecht, H G; Casey, D T; Sio, H; Ruszczynski, J K; Zhou, L; Gatu Johnson, M; Frenje, J A; Séguin, F H; Li, C K; Petrasso, R D; Ruiz, C L; Leeper, R J
2012-04-01
The MIT Linear Electrostatic Ion Accelerator (LEIA) generates DD and D(3)He fusion products for the development of nuclear diagnostics for Omega, Z, and the National Ignition Facility (NIF). Significant improvements to the system in recent years are presented. Fusion reaction rates, as high as 10(7) s(-1) and 10(6) s(-1) for DD and D(3)He, respectively, are now well regulated with a new ion source and electronic gas control system. Charged fusion products are more accurately characterized, which allows for better calibration of existing nuclear diagnostics. In addition, in situ measurements of the on-target beam profile, made with a CCD camera, are used to determine the metrology of the fusion-product source for particle-counting applications. Finally, neutron diagnostics development has been facilitated by detailed Monte Carlo N-Particle Transport (MCNP) modeling of neutrons in the accelerator target chamber, which is used to correct for scattering within the system. These recent improvements have resulted in a versatile platform, which continues to support the existing nuclear diagnostics while simultaneously facilitating the development of new diagnostics in aid of the National Ignition Campaign at the National Ignition Facility. © 2012 American Institute of Physics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinenian, N.; Manuel, M. J.-E.; Zylstra, A. B.
2012-04-15
The MIT Linear Electrostatic Ion Accelerator (LEIA) generates DD and D{sup 3}He fusion products for the development of nuclear diagnostics for Omega, Z, and the National Ignition Facility (NIF). Significant improvements to the system in recent years are presented. Fusion reaction rates, as high as 10{sup 7} s{sup -1} and 10{sup 6} s{sup -1} for DD and D{sup 3}He, respectively, are now well regulated with a new ion source and electronic gas control system. Charged fusion products are more accurately characterized, which allows for better calibration of existing nuclear diagnostics. In addition, in situ measurements of the on-target beam profile,more » made with a CCD camera, are used to determine the metrology of the fusion-product source for particle-counting applications. Finally, neutron diagnostics development has been facilitated by detailed Monte Carlo N-Particle Transport (MCNP) modeling of neutrons in the accelerator target chamber, which is used to correct for scattering within the system. These recent improvements have resulted in a versatile platform, which continues to support the existing nuclear diagnostics while simultaneously facilitating the development of new diagnostics in aid of the National Ignition Campaign at the National Ignition Facility.« less
Wielpütz, Mark O; Heußel, Claus P; Herth, Felix J F; Kauczor, Hans-Ulrich
2014-03-14
Chest X-ray, computed tomography (CT), and magnetic resonance imaging (MRI) each have characteristic advantages and disadvantages that need to be considered in clinical decision-making. This point is discussed in reference to the main types of lung disease that are encountered in practice. A selective literature search was performed in the PubMed and Google Scholar databases. Existing clinical guidelines on the main types of lung disease and studies concerning radiological diagnosis were also con - sidered in this review. There have been no more than a few large-scale, controlled comparative trials of different radiological techniques. Chest X-ray provides general orientation as an initial diagnostic study and is especially useful in the diagnosis of pneumonia, cancer, and chronic obstructive pulmonary disease (COPD). Multi-detector CT affords nearly isotropic spatial resolution at a radiation dose of only 0.2-5 mSv, much lower than before. Its main indications, according to current guidelines, are tumors, acute pulmonary embolism, pulmonary hypertension, pulmonary fibrosis, advanced COPD, and pneumonia in a high-risk patient. MRI is used in the diagnosis of cystic fibrosis, pulmonary embolism, pulmonary hypertension, and bronchial carcinoma. The positive predictive value (PPV) of a chest X-ray in outpatients with pneumonia is only 27% (gold standard, CT); in contrast, an initial, non-randomized trial of MRI in nosocomial pneumonia revealed a PPV of 95%. For the staging of mediastinal lymph nodes in bronchial carcinoma, MRI has a PPV of 88% and positron emission tomography with CT (PET/CT) has a PPV of 79%, while CT alone has a PPV of 41% (gold standard, histology). The choice of radiologicalal technique for the detection, staging, follow-up, and quantification of lung disease should be based on the individual clinical options, so that appropriate treatment can be provided without excessive use of diagnostic testing.
NASA Astrophysics Data System (ADS)
Krupinski, Elizabeth A.; Berbaum, Kevin S.; Caldwell, Robert; Schartz, Kevin M.
2012-02-01
Radiologists are reading more cases with more images, especially in CT and MRI and thus working longer hours than ever before. There have been concerns raised regarding fatigue and whether it impacts diagnostic accuracy. This study measured the impact of reader visual fatigue by assessing symptoms, visual strain via dark focus of accommodation, and diagnostic accuracy. Twenty radiologists and 20 radiology residents were given two diagnostic performance tests searching CT chest sequences for a solitary pulmonary nodule before (rested) and after (tired) a day of clinical reading. 10 cases used free search and navigation, and the other 100 cases used preset scrolling speed and duration. Subjects filled out the Swedish Occupational Fatigue Inventory (SOFI) and the oculomotor strain subscale of the Simulator Sickness Questionnaire (SSQ) before each session. Accuracy was measured using ROC techniques. Using Swensson's technique yields an ROC area = 0.86 rested vs. 0.83 tired, p (one-tailed) = 0.09. Using Swensson's LROC technique yields an area = 0.73 rested vs. 0.66 tired, p (one-tailed) = 0.09. Using Swensson's Loc Accuracy technique yields an area = 0.77 rested vs. 0.72 tired, p (one-tailed) = 0.13). Subjective measures of fatigue increased significantly from early to late reading. To date, the results support our findings with static images and detection of bone fractures. Radiologists at the end of a long work day experience greater levels of measurable visual fatigue or strain, contributing to a decrease in diagnostic accuracy. The decrease in accuracy was not as great however as with static images.
Randall, David; Joosten, Frank; ten Broek, Richard; Gillott, Richard; Bardhan, Karna Dev; Strik, Chema; Prins, Wiesje; van Goor, Harry; Fenner, John
2017-07-14
A non-invasive diagnostic technique for abdominal adhesions is not currently available. Capture of abdominal motion due to respiration in cine-MRI has shown promise, but is difficult to interpret. This article explores the value of a complimentary diagnostic aid to facilitate the non-invasive detection of abdominal adhesions using cine-MRI. An image processing technique was developed to quantify the amount of sliding that occurs between the organs of the abdomen and the abdominal wall in sagittal cine-MRI slices. The technique produces a 'sheargram' which depicts the amount of sliding which has occurred over 1-3 respiratory cycles. A retrospective cohort of 52 patients, scanned for suspected adhesions, made 281 cine-MRI sagittal slices available for processing. The resulting sheargrams were reported by two operators and compared to expert clinical judgement of the cine-MRI scans. The sheargram matched clinical judgement in 84% of all sagittal slices and 93-96% of positive adhesions were identified on the sheargram. The sheargram displayed a slight skew towards sensitivity over specificity, with a high positive adhesion detection rate but at the expense of false positives. Good correlation between sheargram and absence/presence of inferred adhesions indicates quantification of sliding motion has potential to aid adhesion detection in cine-MRI. Advances in Knowledge: This is the first attempt to clinically evaluate a novel image processing technique quantifying the sliding motion of the abdominal contents against the abdominal wall. The results of this pilot study reveal its potential as a diagnostic aid for detection of abdominal adhesions.
NASA Astrophysics Data System (ADS)
Davies, N.; Davies-Shaw, D.; Shaw, J. D.
2007-02-01
We report firsthand on innovative developments in non-invasive, biophotonic techniques for a wide range of diagnostic, imaging and treatment options, including the recognition and quantification of cancerous, pre-cancerous cells and chronic inflammatory conditions. These techniques have benefited from the ability to target the affected site by both monochromatic light and broad multiple wavelength spectra. The employment of such wavelength or color-specific properties embraces the fluorescence stimulation of various photosensitizing drugs, and the instigation and detection of identified fluorescence signatures attendant upon laser induced fluorescence (LIF) phenomena as transmitted and propagated by precancerous, cancerous and normal tissue. In terms of tumor imaging and therapeutic and treatment options, we have exploited the abilities of various wavelengths to penetrate to different depths, through different types of tissues, and have explored quantifiable absorption and reflection characteristics upon which diagnostic assumptions can be reliably based and formulated. These biophotonic-based diagnostic, sensing and imaging techniques have also benefited from, and have been further enhanced by, the integrated ability to provide various power levels to be employed at various stages in the procedure. Applications are myriad, including non-invasive, non destructive diagnosis of in vivo cell characteristics and functions; light-based tissue analysis; real-time monitoring and mapping of brain function and of tumor growth; real time monitoring of the surgical completeness of tumor removal during laser-imaged/guided brain resection; diagnostic procedures based on fluorescence life-time monitoring, the monitoring of chronic inflammatory conditions (including rheumatoid arthritis), and continuous blood glucose monitoring in the control of diabetes.
Laboratory investigations of earthquake dynamics
NASA Astrophysics Data System (ADS)
Xia, Kaiwen
In this thesis this will be attempted through controlled laboratory experiments that are designed to mimic natural earthquake scenarios. The earthquake dynamic rupturing process itself is a complicated phenomenon, involving dynamic friction, wave propagation, and heat production. Because controlled experiments can produce results without assumptions needed in theoretical and numerical analysis, the experimental method is thus advantageous over theoretical and numerical methods. Our laboratory fault is composed of carefully cut photoelastic polymer plates (Homahte-100, Polycarbonate) held together by uniaxial compression. As a unique unit of the experimental design, a controlled exploding wire technique provides the triggering mechanism of laboratory earthquakes. Three important components of real earthquakes (i.e., pre-existing fault, tectonic loading, and triggering mechanism) correspond to and are simulated by frictional contact, uniaxial compression, and the exploding wire technique. Dynamic rupturing processes are visualized using the photoelastic method and are recorded via a high-speed camera. Our experimental methodology, which is full-field, in situ, and non-intrusive, has better control and diagnostic capacity compared to other existing experimental methods. Using this experimental approach, we have investigated several problems: dynamics of earthquake faulting occurring along homogeneous faults separating identical materials, earthquake faulting along inhomogeneous faults separating materials with different wave speeds, and earthquake faulting along faults with a finite low wave speed fault core. We have observed supershear ruptures, subRayleigh to supershear rupture transition, crack-like to pulse-like rupture transition, self-healing (Heaton) pulse, and rupture directionality.
Plasmonic SERS nanochips and nanoprobes for medical diagnostics and bio-energy applications
NASA Astrophysics Data System (ADS)
Ngo, Hoan T.; Wang, Hsin-Neng; Crawford, Bridget M.; Fales, Andrew M.; Vo-Dinh, Tuan
2017-02-01
The development of rapid, easy-to-use, cost-effective, high accuracy, and high sensitive DNA detection methods for molecular diagnostics has been receiving increasing interest. Over the last five years, our laboratory has developed several chip-based DNA detection techniques including the molecular sentinel-on-chip (MSC), the multiplex MSC, and the inverse molecular sentinel-on-chip (iMS-on-Chip). In these techniques, plasmonic surface-enhanced Raman scattering (SERS) Nanowave chips were functionalized with DNA probes for single-step DNA detection. Sensing mechanisms were based on hybridization of target sequences and DNA probes, resulting in a distance change between SERS reporters and the Nanowave chip's gold surface. This distance change resulted in change in SERS intensity, thus indicating the presence and capture of the target sequences. Our techniques were single-step DNA detection techniques. Target sequences were detected by simple delivery of sample solutions onto DNA probe-functionalized Nanowave chips and SERS signals were measured after 1h - 2h incubation. Target sequence labeling or washing to remove unreacted components was not required, making the techniques simple, easy-to-use, and cost effective. The usefulness of the techniques for medical diagnostics was illustrated by the detection of genetic biomarkers for respiratory viral infection and of dengue virus 4 DNA.
Diagnosis of Posttraumatic Stress Disorder in Preschool Children
ERIC Educational Resources Information Center
De Young, Alexandra C.; Kenardy, Justin A.; Cobham, Vanessa E.
2011-01-01
This study investigated the existing diagnostic algorithms for posttraumatic stress disorder (PTSD) to determine the most developmentally sensitive and valid approach for diagnosing this disorder in preschoolers. Participants were 130 parents of unintentionally burned children (1-6 years). Diagnostic interviews were conducted with parents to…
Skin blotting: a noninvasive technique for evaluating physiological skin status.
Minematsu, Takeo; Horii, Motoko; Oe, Makoto; Sugama, Junko; Mugita, Yuko; Huang, Lijuan; Nakagami, Gojiro; Sanada, Hiromi
2014-06-01
The skin performs important structural and physiological functions, and skin assessment represents an important step in identifying skin problems. Although noninvasive techniques for assessing skin status exist, no such techniques for monitoring its physiological status are available. This study aimed to develop a novel skin-assessment technique known as skin blotting, based on the leakage of secreted proteins from inside the skin following overhydration in mice. The applicability of this technique was further investigated in a clinical setting. Skin blotting involves 2 steps: collecting proteins by attaching a damp nitrocellulose membrane to the surface of the skin, and immunostaining the collected proteins. The authors implanted fluorescein-conjugated dextran (F-DEX)-containing agarose gels into mice and detected the tissue distribution of F-DEX under different blotting conditions. They also analyzed the correlations between inflammatory cytokine secretion and leakage following ultraviolet irradiation in mice and in relation to body mass index in humans. The F-DEX in mice was distributed in the deeper and shallower layers of skin and leaked through the transfollicular and transepidermal routes, respectively. Ultraviolet irradiation induced tumor necrosis factor secretion in the epidermis in mice, which was detected by skin blotting, whereas follicular tumor necrosis factor was associated with body mass index in obese human subjects. These results support the applicability of skin blotting for skin assessment. Skin blotting represents a noninvasive technique for assessing skin physiology and has potential as a predictive and diagnostic tool for skin disorders.
Artificial neural networks in mammography interpretation and diagnostic decision making.
Ayer, Turgay; Chen, Qiushi; Burnside, Elizabeth S
2013-01-01
Screening mammography is the most effective means for early detection of breast cancer. Although general rules for discriminating malignant and benign lesions exist, radiologists are unable to perfectly detect and classify all lesions as malignant and benign, for many reasons which include, but are not limited to, overlap of features that distinguish malignancy, difficulty in estimating disease risk, and variability in recommended management. When predictive variables are numerous and interact, ad hoc decision making strategies based on experience and memory may lead to systematic errors and variability in practice. The integration of computer models to help radiologists increase the accuracy of mammography examinations in diagnostic decision making has gained increasing attention in the last two decades. In this study, we provide an overview of one of the most commonly used models, artificial neural networks (ANNs), in mammography interpretation and diagnostic decision making and discuss important features in mammography interpretation. We conclude by discussing several common limitations of existing research on ANN-based detection and diagnostic models and provide possible future research directions.
Diagnostic tools for nearest neighbors techniques when used with satellite imagery
Ronald E. McRoberts
2009-01-01
Nearest neighbors techniques are non-parametric approaches to multivariate prediction that are useful for predicting both continuous and categorical forest attribute variables. Although some assumptions underlying nearest neighbor techniques are common to other prediction techniques such as regression, other assumptions are unique to nearest neighbor techniques....
Definition of periprosthetic joint infection: is there a consensus?
Parvizi, Javad; Jacovides, Christina; Zmistowski, Benjamin; Jung, Kwang Am
2011-11-01
The diagnosis of periprosthetic joint infection (PJI) continues to pose a challenge. While many diagnostic criteria have been proposed, a gold standard for diagnosis is lacking. Use of multiple diagnostic criteria within the joint arthroplasty community raises concerns in patient treatment and comparison of research pertaining to PJI. We (1) determined the variation in existing diagnostic criteria, (2) compared the existing criteria to a proposed new set of criteria that incorporates aspirate cell count analysis, and (3) investigated the variations between the existing criteria and the proposed criteria. We retrospectively identified 182 patients undergoing 192 revision knee arthroplasties who had a preoperative joint aspiration analysis at our institution between April 2002 and November 2009. We excluded 20 cases due to insufficient laboratory parameters, leaving 172 cases for analysis. We applied six previously published sets of diagnostic criteria for PJI to determine the variation in its incidence using each set of criteria. We then compared these diagnostic criteria to our proposed new criteria and investigated cases where disagreement occurred. We identified 41 cases (24%) in which at least one established criteria set classified the case as infected while at least one other criteria set classified the case as uninfected. With our proposed criteria, the infected/uninfected ratio was 92/80. The proposed criteria had a large variance in sensitivity (54%-100%), specificity (39%-100%), and accuracy (53%-100%) when using each of the established criteria sets as the reference standard. The discrepancy between definitions of infection complicates interpretation of the literature and the treatment of failed TKAs owing to PJI. Based on our findings, we suggest establishing a common set of diagnostic criteria utilizing aspirate analysis to improve the treatment of PJI and facilitate interpretation of the literature. Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.
An evaluation of consensus techniques for diagnostic interpretation
NASA Astrophysics Data System (ADS)
Sauter, Jake N.; LaBarre, Victoria M.; Furst, Jacob D.; Raicu, Daniela S.
2018-02-01
Learning diagnostic labels from image content has been the standard in computer-aided diagnosis. Most computer-aided diagnosis systems use low-level image features extracted directly from image content to train and test machine learning classifiers for diagnostic label prediction. When the ground truth for the diagnostic labels is not available, reference truth is generated from the experts diagnostic interpretations of the image/region of interest. More specifically, when the label is uncertain, e.g. when multiple experts label an image and their interpretations are different, techniques to handle the label variability are necessary. In this paper, we compare three consensus techniques that are typically used to encode the variability in the experts labeling of the medical data: mean, median and mode, and their effects on simple classifiers that can handle deterministic labels (decision trees) and probabilistic vectors of labels (belief decision trees). Given that the NIH/NCI Lung Image Database Consortium (LIDC) data provides interpretations for lung nodules by up to four radiologists, we leverage the LIDC data to evaluate and compare these consensus approaches when creating computer-aided diagnosis systems for lung nodules. First, low-level image features of nodules are extracted and paired with their radiologists semantic ratings (1= most likely benign, , 5 = most likely malignant); second, machine learning multi-class classifiers that handle deterministic labels (decision trees) and probabilistic vectors of labels (belief decision trees) are built to predict the lung nodules semantic ratings. We show that the mean-based consensus generates the most robust classi- fier overall when compared to the median- and mode-based consensus. Lastly, the results of this study show that, when building CAD systems with uncertain diagnostic interpretation, it is important to evaluate different strategies for encoding and predicting the diagnostic label.
Simopoulos, Thomas T; Manchikanti, Laxmaiah; Gupta, Sanjeeva; Aydin, Steve M; Kim, Chong Hwan; Solanki, Daneshvari; Nampiaparampil, Devi E; Singh, Vijay; Staats, Peter S; Hirsch, Joshua A
2015-01-01
The sacroiliac joint is well known as a cause of low back and lower extremity pain. Prevalence estimates are 10% to 25% in patients with persistent axial low back pain without disc herniation, discogenic pain, or radiculitis based on multiple diagnostic studies and systematic reviews. However, at present there are no definitive management options for treating sacroiliac joint pain. To evaluate the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. A systematic review of the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. The available literature on diagnostic and therapeutic sacroiliac joint interventions was reviewed. The quality assessment criteria utilized were the Quality Appraisal of Reliability Studies (QAREL) checklist for diagnostic accuracy studies, Cochrane review criteria to assess sources of risk of bias, and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment (IPM-QRB) criteria for randomized therapeutic trials and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment for Nonrandomized Studies (IPM-QRBNR) for observational therapeutic assessments. The level of evidence was based on a best evidence synthesis with modified grading of qualitative evidence from Level I to Level V. Data sources included relevant literature published from 1966 through March 2015 that were identified through searches of PubMed and EMBASE, manual searches of the bibliographies of known primary and review articles, and all other sources. For the diagnostic accuracy assessment, and for the therapeutic modalities, the primary outcome measure of pain relief and improvement in functional status were utilized. A total of 11 diagnostic accuracy studies and 14 therapeutic studies were included. The evidence for diagnostic accuracy is Level II for dual diagnostic blocks with at least 70% pain relief as the criterion standard and Level III evidence for single diagnostic blocks with at least 75% pain relief as the criterion standard. The evidence for cooled radiofrequency neurotomy in managing sacroiliac joint pain is Level II to III. The evidence for conventional radiofrequency neurotomy, intraarticular steroid injections, and periarticular injections with steroids or botulinum toxin is limited: Level III or IV. The limitations of this systematic review include inconsistencies in diagnostic accuracy studies with a paucity of high quality, replicative, and consistent literature. The limitations for therapeutic interventions include variations in technique, variable diagnostic standards for inclusion criteria, and variable results. The evidence for the accuracy of diagnostic and therapeutic effectiveness of sacroiliac joint interventions varied from Level II to Level IV.
Biosafety principles and practices for the veterinary diagnostic laboratory.
Kozlovac, Joseph; Schmitt, Beverly
2015-01-01
Good biosafety and biocontainment programs and practices are critical components of the successful operation of any veterinary diagnostic laboratory. In this chapter we provide information and guidance on critical biosafety management program elements, facility requirements, protective equipment, and procedures necessary to ensure that the laboratory worker and the environment are adequately protected in the challenging work environment of the veterinary diagnostic laboratory in general and provide specific guidance for those laboratories employing molecular diagnostic techniques.
New developments for the detection and treatment of cardiac vasculopathy.
Clerkin, Kevin J; Ali, Ziad A; Mancini, Donna M
2017-02-15
Cardiac allograft vasculopathy (CAV) is a major limitation to long-term survival after heart transplantation. Innovative new techniques to diagnose CAV have been applied to detect disease. This review will examine the current diagnostic and treatment options available to clinicians for CAV. Diagnostic modalities addressing the pathophysiology underlying CAV (arterial wall thickening and decreased coronary blood flow) improve diagnostic sensitivity when compared to traditional (angiography and dobutamine stress echocardiography) techniques. Limited options are available to prevent and treat CAV; however, progress has been made in making an earlier and more accurate diagnosis. Future research is needed to identify the optimal time to modify immunosuppression and investigate novel treatments for CAV.
Yamaguti, M.; Muller, E.E.; Piffer, A.I.; Kich, J.D.; Klein, C.S.; Kuchiishi, S.S.
2008-01-01
Since Mycoplasma hyopneumoniae isolation in appropriate media is a difficult task and impractical for daily routine diagnostics, Nested-PCR (N-PCR) techniques are currently used to improve the direct diagnostic sensitivity of Swine Enzootic Pneumonia. In a first experiment, this paper describes a N-PCR technique optimization based on three variables: different sampling sites, sample transport media, and DNA extraction methods, using eight pigs. Based on the optimization results, a second experiment was conducted for testing validity using 40 animals. In conclusion, the obtained results of the N-PCR optimization and validation allow us to recommend this test as a routine monitoring diagnostic method for Mycoplasma hyopneumoniae infection in swine herds. PMID:24031248
Aquifer test interpretation using derivative analysis and diagnostic plots
NASA Astrophysics Data System (ADS)
Hernández-Espriú, Antonio; Real-Rangel, Roberto; Cortés-Salazar, Iván; Castro-Herrera, Israel; Luna-Izazaga, Gabriela; Sánchez-León, Emilio
2017-04-01
Pumping tests remain a method of choice to deduce fundamental aquifer properties and to assess well condition. In the oil and gas (O&G) industry, well testing has been the core technique in examining reservoir behavior over the last 50 years. The pressure derivative by Bourdet, it is perhaps, the most significant single development in the history of well test analysis. Recently, the so-called diagnostics plots (e.g. drawdown and drawdown derivative in a log-log plot) have been successfully tested in aquifers. However, this procedure is still underutilized by groundwater professionals. This research illustrates the applicability range, advantages and drawbacks (e.g. smoothing procedures) of diagnostic plots using field examples from a wide spectrum of tests (short/long tests, constant/variable flow rates, drawdown/buildup stages, pumping well/observation well) in dissimilar geological conditions. We analyze new and pre-existent aquifer tests in Mexico, USA, Canada, Germany, France and Saudi Arabia. In constant flow rate tests, our results show that derivative analysis is an easy, robust and powerful tool to assess near-borehole damage effects, formation heterogeneity, boundaries, flow regimes, infinite-acting radial stages, i.e., valid Theisian framework, and fracture-driven flow. In step tests, the effectiveness relies on high-frequency drawdown measurements. Moreover, we adapt O&G analytical solutions to cater for the conditions in groundwater systems. In this context, further parameters can be computed analytically from the plots, such as skin factor, head losses, wellbore storage, distance to the boundary, channel-aquifer and/or fracture zone width, among others. Therefore, diagnostic plots should be considered a mandatory tool for pumping tests analysis among hydrogeologists. This project has been supported by DGAPA (UNAM) under the research project PAPIIT IN-112815.
[Current macro-diagnostic trends of forensic medicine in the Czech Republic].
Frišhons, Jan; Kučerová, Štěpánka; Jurda, Mikoláš; Sokol, Miloš; Vojtíšek, Tomáš; Hejna, Petr
2017-01-01
Over the last few years, advanced diagnostic methods have penetrated in the realm of forensic medicine in addition to standard autopsy techniques supported by traditional X-ray examination and macro-diagnostic laboratory tests. Despite the progress of imaging methods, the conventional autopsy has remained basic and essential diagnostic tool in forensic medicine. Postmortem computed tomography and magnetic resonance imaging are far the most progressive modern radio diagnostic methods setting the current trend of virtual autopsies all over the world. Up to now, only two institutes of forensic medicine have available postmortem computed tomography for routine diagnostic purposes in the Czech Republic. Postmortem magnetic resonance is currently unattainable for routine diagnostic use and was employed only for experimental purposes. Photogrammetry is digital method focused primarily on body surface imaging. Recently, the most fruitful results have been yielded from the interdisciplinary cooperation between forensic medicine and forensic anthropology with the implementation of body scanning techniques and 3D printing. Non-invasive and mini-invasive investigative methods such as postmortem sonography and postmortem endoscopy was unsystematically tested for diagnostic performance with good outcomes despite of limitations of these methods in postmortem application. Other futuristic methods, such as the use of a drone to inspect the crime scene are still experimental tools. The authors of the article present a basic overview of the both routinely and experimentally used investigative methods and current macro-diagnostic trends of the forensic medicine in the Czech Republic.
When BVD doesn't look like BVD
USDA-ARS?s Scientific Manuscript database
Due to the sheer number of different clinical presentations existing under the BVD umbrella, diagnosing BVD based on clinical signs is not advisable. Thus diagnosis relies upon testing of samples in diagnostic laboratories. In the US, most of the diagnostic effort has been focused on identifying a...
Current ante-mortem techniques for diagnosis of bovine tuberculosis.
Bezos, Javier; Casal, Carmen; Romero, Beatriz; Schroeder, Bjoern; Hardegger, Roland; Raeber, Alex J; López, Lissette; Rueda, Paloma; Domínguez, Lucas
2014-10-01
Bovine tuberculosis (TB), mainly caused by Mycobacterium bovis, is a zoonotic disease with implications for Public Health and having an economic impact due to decreased production and limitations to the trade. Bovine TB is subjected to official eradication campaigns mainly based on a test and slaughter policy using diagnostic assays based on the cell-mediated immune response as the intradermal tuberculin test and the gamma-interferon (IFN-γ) assay. Moreover, several diagnostic assays based on the detection of specific antibodies (Abs) have been developed in the last few years with the aim of complementing the current diagnostic techniques in the near future. This review provides an overview of the current ante-mortem diagnostic tools for diagnosis of bovine TB regarding historical background, methodologies and sensitivity (Se) and specificity (Sp) obtained in previous studies under different epidemiological situations. Copyright © 2014 Elsevier Ltd. All rights reserved.
Integrated Data Analysis for Fusion: A Bayesian Tutorial for Fusion Diagnosticians
NASA Astrophysics Data System (ADS)
Dinklage, Andreas; Dreier, Heiko; Fischer, Rainer; Gori, Silvio; Preuss, Roland; Toussaint, Udo von
2008-03-01
Integrated Data Analysis (IDA) offers a unified way of combining information relevant to fusion experiments. Thereby, IDA meets with typical issues arising in fusion data analysis. In IDA, all information is consistently formulated as probability density functions quantifying uncertainties in the analysis within the Bayesian probability theory. For a single diagnostic, IDA allows the identification of faulty measurements and improvements in the setup. For a set of diagnostics, IDA gives joint error distributions allowing the comparison and integration of different diagnostics results. Validation of physics models can be performed by model comparison techniques. Typical data analysis applications benefit from IDA capabilities of nonlinear error propagation, the inclusion of systematic effects and the comparison of different physics models. Applications range from outlier detection, background discrimination, model assessment and design of diagnostics. In order to cope with next step fusion device requirements, appropriate techniques are explored for fast analysis applications.
Protein electrophoresis as a diagnostic and prognostic tool in raptor medicine.
Tatum, L M; Zaias, J; Mealey, B K; Cray, C; Bossart, G D
2000-12-01
Plasma proteins of 139 healthy adult birds of prey from 10 species were separated by electrophoresis to characterize and document normal reference ranges and species-specific electrophoretic patternsand to evaluate the value of this technique for health screening, disease diagnosis, and prognostic indication. Species studied included bald eagle (Haliaeetus leucocephalus), red-tailed hawk (Buteo jamaicensis), barn owl (Tyto alba), great horned owl (Bubo virginianus), turkey vulture (Cathartes aura), Harris' hawk (Parabuteo unicinctus), Stellar's sea eagle (Haliaeetus pelagicus), barred owl (Strix varia), screech owl (Otus asio), and black vulture (Coragyps atratus). Several clinical cases show the diagnostic/therapeutic value of protein electrophoresis in raptors. This study establishes species-specific reference ranges for several birds of prey and discusses the benefit of electrophoresis as a diagnostic technique in health screens, as a diagnostic aid in conjunction with other tests, and as a prognostic indicator in clinical evaluation of raptors.
NASA Astrophysics Data System (ADS)
Unger, Jakob; Sun, Tianchen; Chen, Yi-Ling; Phipps, Jennifer E.; Bold, Richard J.; Darrow, Morgan A.; Ma, Kwan-Liu; Marcu, Laura
2018-01-01
An important step in establishing the diagnostic potential for emerging optical imaging techniques is accurate registration between imaging data and the corresponding tissue histopathology typically used as gold standard in clinical diagnostics. We present a method to precisely register data acquired with a point-scanning spectroscopic imaging technique from fresh surgical tissue specimen blocks with corresponding histological sections. Using a visible aiming beam to augment point-scanning multispectral time-resolved fluorescence spectroscopy on video images, we evaluate two different markers for the registration with histology: fiducial markers using a 405-nm CW laser and the tissue block's outer shape characteristics. We compare the registration performance with benchmark methods using either the fiducial markers or the outer shape characteristics alone to a hybrid method using both feature types. The hybrid method was found to perform best reaching an average error of 0.78±0.67 mm. This method provides a profound framework to validate diagnostical abilities of optical fiber-based techniques and furthermore enables the application of supervised machine learning techniques to automate tissue characterization.
Mason, Jay W; Hancock, E William; Gettes, Leonard S
2007-03-01
This statement provides a concise list of diagnostic terms for ECG interpretation that can be shared by students, teachers, and readers of electrocardiography. This effort was motivated by the existence of multiple automated diagnostic code sets containing imprecise and overlapping terms. An intended outcome of this statement list is greater uniformity of ECG diagnosis and a resultant improvement in patient care. The lexicon includes primary diagnostic statements, secondary diagnostic statements, modifiers, and statements for the comparison of ECGs. This diagnostic lexicon should be reviewed and updated periodically.
Chang, Ruey-Feng; Lee, Chung-Chien; Lo, Chung-Ming
2016-09-01
The lifetime prevalence of shoulder pain approaches 70%, which is mostly attributable to rotator cuff lesions such as inflammation, calcific tendinitis and tears. On clinical examination, shoulder ultrasound is recommended for the detection of lesions. However, there exists inter-operator variability in diagnostic accuracy because of differences in the experience and expertise of operators. In this study, a computer-aided diagnosis (CAD) system was developed to assist ultrasound operators in diagnosing rotator cuff lesions and to improve the practicality of ultrasound examination. The collected cases included 43 cases of inflammation, 30 cases of calcific tendinitis and 26 tears. For each case, the lesion area and texture features were extracted from the entire lesions and combined in a multinomial logistic regression classifier for lesion classification. The proposed CAD achieved an accuracy of 87.9%. The individual accuracy of this CAD system was 88.4% for inflammation, 83.3% for calcific tendinitis and 92.3% for tears. Cohen's k was 0.798. On the basis of its diagnostic performance, clinical use of this CAD technique has promise. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
In situ surface/interface x-ray diffractometer for oxide molecular beam epitaxy
Lee, J. H.; Tung, I. C.; Chang, S. -H.; ...
2016-01-05
In situ studies of oxide molecular beam epitaxy by synchrotron x-ray scattering has been made possible by upgrading an existing UHV/molecular beam epitaxy (MBE) six-circle diffractometer system. For oxide MBE growth, pure ozone delivery to the chamber has been made available, and several new deposition sources have been made available on a new 12 in. CF (ConFlat, a registered trademark of Varian, Inc.) flange. X-ray diffraction has been used as a major probe for film growth and structures for the system. In the original design, electron diffraction was intended for the secondary diagnostics available without the necessity of the x-raymore » and located at separate positions. Deposition of films was made possible at the two diagnostic positions. And, the aiming of the evaporation sources is fixed to the point between two locations. Ozone can be supplied through two separate nozzles for each location. Also two separate thickness monitors are installed. Finally, additional features of the equipment are also presented together with the data taken during typical oxide film growth to illustrate the depth of information available via in situ x-ray techniques.« less
Disk Crack Detection for Seeded Fault Engine Test
NASA Technical Reports Server (NTRS)
Luo, Huageng; Rodriguez, Hector; Hallman, Darren; Corbly, Dennis; Lewicki, David G. (Technical Monitor)
2004-01-01
Work was performed to develop and demonstrate vibration diagnostic techniques for the on-line detection of engine rotor disk cracks and other anomalies through a real engine test. An existing single-degree-of-freedom non-resonance-based vibration algorithm was extended to a multi-degree-of-freedom model. In addition, a resonance-based algorithm was also proposed for the case of one or more resonances. The algorithms were integrated into a diagnostic system using state-of-the- art commercial analysis equipment. The system required only non-rotating vibration signals, such as accelerometers and proximity probes, and the rotor shaft 1/rev signal to conduct the health monitoring. Before the engine test, the integrated system was tested in the laboratory by using a small rotor with controlled mass unbalances. The laboratory tests verified the system integration and both the non-resonance and the resonance-based algorithm implementations. In the engine test, the system concluded that after two weeks of cycling, the seeded fan disk flaw did not propagate to a large enough size to be detected by changes in the synchronous vibration. The unbalance induced by mass shifting during the start up and coast down was still the dominant response in the synchronous vibration.
From molecular biology to nanotechnology and nanomedicine.
Bogunia-Kubik, Katarzyna; Sugisaka, Masanori
2002-01-01
Great progress in the development of molecular biology techniques has been seen since the discovery of the structure of deoxyribonucleic acid (DNA) and the implementation of a polymerase chain reaction (PCR) method. This started a new era of research on the structure of nucleic acids molecules, the development of new analytical tools, and DNA-based analyses. The latter included not only diagnostic procedures but also, for example, DNA-based computational approaches. On the other hand, people have started to be more interested in mimicking real life, and modeling the structures and organisms that already exist in nature for the further evaluation and insight into their behavior and evolution. These factors, among others, have led to the description of artificial organelles or cells, and the construction of nanoscale devices. These nanomachines and nanoobjects might soon find a practical implementation, especially in the field of medical research and diagnostics. The paper presents some examples, illustrating the progress in multidisciplinary research in the nanoscale area. It is focused especially on immunogenetics-related aspects and the wide usage of DNA molecules in various fields of science. In addition, some proposals for nanoparticles and nanoscale tools and their applications in medicine are reviewed and discussed.
Lentz, Robert J; Argento, A Christine; Colby, Thomas V; Rickman, Otis B; Maldonado, Fabien
2017-07-01
Transbronchial lung biopsy with a cryoprobe, or cryobiopsy, is a promising new bronchoscopic biopsy technique capable of obtaining larger and better-preserved samples than previously possible using traditional biopsy forceps. Over two dozen case series and several small randomized trials are now available describing experiences with this technique, largely for the diagnosis of diffuse parenchymal lung disease (DPLD), in which the reported diagnostic yield is typically 70% to 80%. Cryobiopsy technique varies widely between centers and this predominantly single center-based retrospective literature heterogeneously defines diagnostic yield and complications, limiting the degree to which this technique can be compared between centers or to surgical lung biopsy (SLB). This review explores the broad range of cryobiopsy techniques currently in use, their rationale, the current state of the literature, and suggestions for the direction of future study into this promising but unproven procedure.
Diagnosing Alzheimer's disease: a systematic review of economic evaluations.
Handels, Ron L H; Wolfs, Claire A G; Aalten, Pauline; Joore, Manuela A; Verhey, Frans R J; Severens, Johan L
2014-03-01
The objective of this study is to systematically review the literature on economic evaluations of interventions for the early diagnosis of Alzheimer's disease (AD) and related disorders and to describe their general and methodological characteristics. We focused on the diagnostic aspects of the decision models to assess the applicability of existing decision models for the evaluation of the recently revised diagnostic research criteria for AD. PubMed and the National Institute for Health Research Economic Evaluation database were searched for English-language publications related to economic evaluations on diagnostic technologies. Trial-based economic evaluations were assessed using the Consensus on Health Economic Criteria list. Modeling studies were assessed using the framework for quality assessment of decision-analytic models. The search retrieved 2109 items, from which eight decision-analytic modeling studies and one trial-based economic evaluation met all eligibility criteria. Diversity among the study objective and characteristics was considerable and, despite considerable methodological quality, several flaws were indicated. Recommendations were focused on diagnostic aspects and the applicability of existing models for the evaluation of recently revised diagnostic research criteria for AD. Copyright © 2014 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
A real-time diagnostic and performance monitor for UNIX. M.S. Thesis
NASA Technical Reports Server (NTRS)
Dong, Hongchao
1992-01-01
There are now over one million UNIX sites and the pace at which new installations are added is steadily increasing. Along with this increase, comes a need to develop simple efficient, effective and adaptable ways of simultaneously collecting real-time diagnostic and performance data. This need exists because distributed systems can give rise to complex failure situations that are often un-identifiable with single-machine diagnostic software. The simultaneous collection of error and performance data is also important for research in failure prediction and error/performance studies. This paper introduces a portable method to concurrently collect real-time diagnostic and performance data on a distributed UNIX system. The combined diagnostic/performance data collection is implemented on a distributed multi-computer system using SUN4's as servers. The approach uses existing UNIX system facilities to gather system dependability information such as error and crash reports. In addition, performance data such as CPU utilization, disk usage, I/O transfer rate and network contention is also collected. In the future, the collected data will be used to identify dependability bottlenecks and to analyze the impact of failures on system performance.
NASA Astrophysics Data System (ADS)
Wang, Jianfeng; Lin, Kan; Zheng, Wei; Yu Ho, Khek; Teh, Ming; Guan Yeoh, Khay; Huang, Zhiwei
2015-08-01
This work aims to evaluate clinical value of a fiber-optic Raman spectroscopy technique developed for in vivo diagnosis of esophageal squamous cell carcinoma (ESCC) during clinical endoscopy. We have developed a rapid fiber-optic Raman endoscopic system capable of simultaneously acquiring both fingerprint (FP)(800-1800 cm-1) and high-wavenumber (HW)(2800-3600 cm-1) Raman spectra from esophageal tissue in vivo. A total of 1172 in vivo FP/HW Raman spectra were acquired from 48 esophageal patients undergoing endoscopic examination. The total Raman dataset was split into two parts: 80% for training; while 20% for testing. Partial least squares-discriminant analysis (PLS-DA) and leave-one patient-out, cross validation (LOPCV) were implemented on training dataset to develop diagnostic algorithms for tissue classification. PLS-DA-LOPCV shows that simultaneous FP/HW Raman spectroscopy on training dataset provides a diagnostic sensitivity of 97.0% and specificity of 97.4% for ESCC classification. Further, the diagnostic algorithm applied to the independent testing dataset based on simultaneous FP/HW Raman technique gives a predictive diagnostic sensitivity of 92.7% and specificity of 93.6% for ESCC identification, which is superior to either FP or HW Raman technique alone. This work demonstrates that the simultaneous FP/HW fiber-optic Raman spectroscopy technique improves real-time in vivo diagnosis of esophageal neoplasia at endoscopy.
A Testbed for Data Fusion for Helicopter Diagnostics and Prognostics
2003-03-01
and algorithm design and tuning in order to develop advanced diagnostic and prognostic techniques for air craft health monitoring . Here a...and development of models for diagnostics, prognostics , and anomaly detection . Figure 5 VMEP Server Browser Interface 7 Download... detections , and prognostic prediction time horizons. The VMEP system and in particular the web component are ideal for performing data collection
Spatial calibration of a tokamak neutral beam diagnostic using in situ neutral beam emission
Chrystal, Colin; Burrell, Keith H.; Grierson, Brian A.; ...
2015-10-20
Neutral beam injection is used in tokamaks to heat, apply torque, drive non-inductive current, and diagnose plasmas. Neutral beam diagnostics need accurate spatial calibrations to benefit from the measurement localization provided by the neutral beam. A new technique has been developed that uses in-situ measurements of neutral beam emission to determine the spatial location of the beam and the associated diagnostic views. This technique was developed to improve the charge exchange recombination diagnostic (CER) at the DIII-D tokamak and uses measurements of the Doppler shift and Stark splitting of neutral beam emission made by that diagnostic. These measurements contain informationmore » about the geometric relation between the diagnostic views and the neutral beams when they are injecting power. This information is combined with standard spatial calibration measurements to create an integrated spatial calibration that provides a more complete description of the neutral beam-CER system. The integrated spatial calibration results are very similar to the standard calibration results and derived quantities from CER measurements are unchanged within their measurement errors. Lastly, the methods developed to perform the integrated spatial calibration could be useful for tokamaks with limited physical access.« less
Spatial calibration of a tokamak neutral beam diagnostic using in situ neutral beam emission
NASA Astrophysics Data System (ADS)
Chrystal, C.; Burrell, K. H.; Grierson, B. A.; Pace, D. C.
2015-10-01
Neutral beam injection is used in tokamaks to heat, apply torque, drive non-inductive current, and diagnose plasmas. Neutral beam diagnostics need accurate spatial calibrations to benefit from the measurement localization provided by the neutral beam. A new technique has been developed that uses in situ measurements of neutral beam emission to determine the spatial location of the beam and the associated diagnostic views. This technique was developed to improve the charge exchange recombination (CER) diagnostic at the DIII-D tokamak and uses measurements of the Doppler shift and Stark splitting of neutral beam emission made by that diagnostic. These measurements contain information about the geometric relation between the diagnostic views and the neutral beams when they are injecting power. This information is combined with standard spatial calibration measurements to create an integrated spatial calibration that provides a more complete description of the neutral beam-CER system. The integrated spatial calibration results are very similar to the standard calibration results and derived quantities from CER measurements are unchanged within their measurement errors. The methods developed to perform the integrated spatial calibration could be useful for tokamaks with limited physical access.
Berretta, Massimiliano; Cavaliere, Carla; Facchini, Gaetano; Balestreri, Luca; Perin, Tiziana; Canzonieri, Vincenzo
2017-01-01
HCC represents the sixth most common cancer worldwide and the second leading cause of cancer-related death. Despite the high incidence, treatment options for advanced HCC remain limited and unsuccessful, resulting in a poor prognosis. Despite the major advances achieved in the diagnostic management of HCC, only one third of the newly diagnosed patients are presently eligible for curative treatments. Advances in technology and an increased understanding of HCC biology have led to the discovery of novel biomarkers. Improving our knowledge about serum and tissutal markers could ultimately lead to an early diagnosis and better and early treatment strategies for this deadly disease. Serum biomarkers are striking potential tools for surveillance and early diagnosis of HCC thanks to the non-invasive, objective, and reproducible assessments they potentially enable. To date, many biomarkers have been proposed in the diagnosis of HCC. Cholangiocarcinoma (CCA) is an aggressive malignancy, characterized by early lymph node involvement and distant metastasis, with 5-year survival rates of 5%-10%. The identification of new biomarkers with diagnostic, prognostic or predictive value is especially important as resection (by surgery or combined with a liver transplant) has shown promising results and novel therapies are emerging. However, the relatively low incidence of CCA, high frequency of co-existing cholestasis or cholangitis (primary sclerosing cholangitis –PSC- above all), and difficulties with obtaining adequate samples, despite advances in sampling techniques and in endoscopic visualization of the bile ducts, have complicated the search for accurate biomarkers. In this review, we attempt to analyze the existing literature on this argument. PMID:28077782
A diagnostic technique used to obtain cross range radiation centers from antenna patterns
NASA Technical Reports Server (NTRS)
Lee, T. H.; Burnside, W. D.
1988-01-01
A diagnostic technique to obtain cross range radiation centers based on antenna radiation patterns is presented. This method is similar to the synthetic aperture processing of scattered fields in the radar application. Coherent processing of the radiated fields is used to determine the various radiation centers associated with the far-zone pattern of an antenna for a given radiation direction. This technique can be used to identify an unexpected radiation center that creates an undesired effect in a pattern; on the other hand, it can improve a numerical simulation of the pattern by identifying other significant mechanisms. Cross range results for two 8' reflector antennas are presented to illustrate as well as validate that technique.
Comparative study on the efficiency of some optical methods for artwork diagnostics
NASA Astrophysics Data System (ADS)
Schirripa Spagnolo, Giuseppe; Ambrosini, Dario; Paoletti, Domenica
2001-10-01
Scientific investigation methods are founding their place besides the stylistic-historical study methods in art research works. In particular, optical techniques, transferred from other fields or developed ad hoc, can make a strong contribution to the safeguarding and exploitation of cultural heritage. This paper describes the use of different optical techniques, such as holographic interferometry, decorrelation, shearography and ESPI, in the diagnostics of works of art. A comparison between different methods is obtained by performing tests on specially designed models, prepared using typical techniques and materials. Inside the model structure, a number of defects of known types, form and extension are inserted. The different features of each technique are outlined and a comparison with IR thermography is also carried out.
Kuru, Kaya; Niranjan, Mahesan; Tunca, Yusuf; Osvank, Erhan; Azim, Tayyaba
2014-10-01
In general, medical geneticists aim to pre-diagnose underlying syndromes based on facial features before performing cytological or molecular analyses where a genotype-phenotype interrelation is possible. However, determining correct genotype-phenotype interrelationships among many syndromes is tedious and labor-intensive, especially for extremely rare syndromes. Thus, a computer-aided system for pre-diagnosis can facilitate effective and efficient decision support, particularly when few similar cases are available, or in remote rural districts where diagnostic knowledge of syndromes is not readily available. The proposed methodology, visual diagnostic decision support system (visual diagnostic DSS), employs machine learning (ML) algorithms and digital image processing techniques in a hybrid approach for automated diagnosis in medical genetics. This approach uses facial features in reference images of disorders to identify visual genotype-phenotype interrelationships. Our statistical method describes facial image data as principal component features and diagnoses syndromes using these features. The proposed system was trained using a real dataset of previously published face images of subjects with syndromes, which provided accurate diagnostic information. The method was tested using a leave-one-out cross-validation scheme with 15 different syndromes, each of comprised 5-9 cases, i.e., 92 cases in total. An accuracy rate of 83% was achieved using this automated diagnosis technique, which was statistically significant (p<0.01). Furthermore, the sensitivity and specificity values were 0.857 and 0.870, respectively. Our results show that the accurate classification of syndromes is feasible using ML techniques. Thus, a large number of syndromes with characteristic facial anomaly patterns could be diagnosed with similar diagnostic DSSs to that described in the present study, i.e., visual diagnostic DSS, thereby demonstrating the benefits of using hybrid image processing and ML-based computer-aided diagnostics for identifying facial phenotypes. Copyright © 2014. Published by Elsevier B.V.
Application of Immunosignatures for Diagnosis of Valley Fever
Navalkar, Krupa Arun; Johnston, Stephen Albert; Woodbury, Neal; Galgiani, John N.; Magee, D. Mitchell; Chicacz, Zbigniew
2014-01-01
Valley fever (VF) is difficult to diagnose, partly because the symptoms of VF are confounded with those of other community-acquired pneumonias. Confirmatory diagnostics detect IgM and IgG antibodies against coccidioidal antigens via immunodiffusion (ID). The false-negative rate can be as high as 50% to 70%, with 5% of symptomatic patients never showing detectable antibody levels. In this study, we tested whether the immunosignature diagnostic can resolve VF false negatives. An immunosignature is the pattern of antibody binding to random-sequence peptides on a peptide microarray. A 10,000-peptide microarray was first used to determine whether valley fever patients can be distinguished from 3 other cohorts with similar infections. After determining the VF-specific peptides, a small 96-peptide diagnostic array was created and tested. The performances of the 10,000-peptide array and the 96-peptide diagnostic array were compared to that of the ID diagnostic standard. The 10,000-peptide microarray classified the VF samples from the other 3 infections with 98% accuracy. It also classified VF false-negative patients with 100% sensitivity in a blinded test set versus 28% sensitivity for ID. The immunosignature microarray has potential for simultaneously distinguishing valley fever patients from those with other fungal or bacterial infections. The same 10,000-peptide array can diagnose VF false-negative patients with 100% sensitivity. The smaller 96-peptide diagnostic array was less specific for diagnosing false negatives. We conclude that the performance of the immunosignature diagnostic exceeds that of the existing standard, and the immunosignature can distinguish related infections and might be used in lieu of existing diagnostics. PMID:24964807
Spiral Bevel Pinion Crack Detection in a Helicopter Gearbox
NASA Technical Reports Server (NTRS)
Decker, Harry J.; Lewicki, David G.
2003-01-01
The vibration resulting from a cracked spiral bevel pinion was recorded and analyzed using existing Health and Usage Monitoring System (HUMS) techniques. A tooth on the input pinion to a Bell OH-58 main rotor gearbox was notched and run for an extended period at severe over-torque condition to facilitate a tooth fracture. Thirteen vibration-based diagnostic metrics were calculated throughout the run. After 101.41 hours of run time, some of the metrics indicated damage. At that point a visual inspection did not reveal any damage. The pinion was then run for another 12 minutes until a proximity probe indicated that a tooth had fractured. This paper discusses the damage detection effectiveness of the different metrics and a comparison of effects of the different accelerometer locations.
Current and emerging techniques for antibiotic susceptibility tests.
Syal, Karan; Mo, Manni; Yu, Hui; Iriya, Rafael; Jing, Wenwen; Guodong, Sui; Wang, Shaopeng; Grys, Thomas E; Haydel, Shelley E; Tao, Nongjian
2017-01-01
Infectious diseases caused by bacterial pathogens are a worldwide burden. Serious bacterial infection-related complications, such as sepsis, affect over a million people every year with mortality rates ranging from 30% to 50%. Crucial clinical microbiology laboratory responsibilities associated with patient management and treatment include isolating and identifying the causative bacterium and performing antibiotic susceptibility tests (ASTs), which are labor-intensive, complex, imprecise, and slow (taking days, depending on the growth rate of the pathogen). Considering the life-threatening condition of a septic patient and the increasing prevalence of antibiotic-resistant bacteria in hospitals, rapid and automated diagnostic tools are needed. This review summarizes the existing commercial AST methods and discusses some of the promising emerging AST tools that will empower humans to win the evolutionary war between microbial genes and human wits.
An overview of glomerular filtration rate testing in dogs and cats
Von Hendy-Willson, Vanessa E.; Pressler, Barrak M.
2010-01-01
Determination of glomerular filtration rate (GFR) is a valuable, yet underused, diagnostic tool for evaluating renal function in dogs and cats. This article first reviews the hormonal and hemodynamic factors which contribute to GFR, followed by a description of considerations when selecting a pharmacokinetic model and methods of animal-to-animal standardization. The best-characterized existing GFR markers, including creatinine, radiolabeled markers, and iohexol, are reviewed in depth, as well as alternative but lesser-used techniques. A weighted means analysis of reported GFR measurements in healthy dogs and cats and a review of selected studies that have examined GFR alterations in animals with naturally-occurring and experimental diseases provide the reader with preliminary guidelines on expected GFR results in these species and disease conditions. PMID:20541957
Current and emerging techniques for antibiotic susceptibility tests
Syal, Karan; Mo, Manni; Yu, Hui; Iriya, Rafael; Jing, Wenwen; Guodong, Sui; Wang, Shaopeng; Grys, Thomas E.; Haydel, Shelley E.; Tao, Nongjian
2017-01-01
Infectious diseases caused by bacterial pathogens are a worldwide burden. Serious bacterial infection-related complications, such as sepsis, affect over a million people every year with mortality rates ranging from 30% to 50%. Crucial clinical microbiology laboratory responsibilities associated with patient management and treatment include isolating and identifying the causative bacterium and performing antibiotic susceptibility tests (ASTs), which are labor-intensive, complex, imprecise, and slow (taking days, depending on the growth rate of the pathogen). Considering the life-threatening condition of a septic patient and the increasing prevalence of antibiotic-resistant bacteria in hospitals, rapid and automated diagnostic tools are needed. This review summarizes the existing commercial AST methods and discusses some of the promising emerging AST tools that will empower humans to win the evolutionary war between microbial genes and human wits. PMID:28638468
Power System Transient Diagnostics Based on Novel Traveling Wave Detection
NASA Astrophysics Data System (ADS)
Hamidi, Reza Jalilzadeh
Modern electrical power systems demand novel diagnostic approaches to enhancing the system resiliency by improving the state-of-the-art algorithms. The proliferation of high-voltage optical transducers and high time-resolution measurements provide opportunities to develop novel diagnostic methods of very fast transients in power systems. At the same time, emerging complex configuration, such as multi-terminal hybrid transmission systems, limits the applications of the traditional diagnostic methods, especially in fault location and health monitoring. The impedance-based fault-location methods are inefficient for cross-bounded cables, which are widely used for connection of offshore wind farms to the main grid. Thus, this dissertation first presents a novel traveling wave-based fault-location method for hybrid multi-terminal transmission systems. The proposed method utilizes time-synchronized high-sampling voltage measurements. The traveling wave arrival times (ATs) are detected by observation of the squares of wavelet transformation coefficients. Using the ATs, an over-determined set of linear equations are developed for noise reduction, and consequently, the faulty segment is determined based on the characteristics of the provided equation set. Then, the fault location is estimated. The accuracy and capabilities of the proposed fault location method are evaluated and also compared to the existing traveling-wave-based method for a wide range of fault parameters. In order to improve power systems stability, auto-reclosing (AR), single-phase auto-reclosing (SPAR), and adaptive single-phase auto-reclosing (ASPAR) methods have been developed with the final objectives of distinguishing between the transient and permanent faults to clear the transient faults without de-energization of the solid phases. However, the features of the electrical arcs (transient faults) are severely influenced by a number of random parameters, including the convection of the air and plasma, wind speed, air pressure, and humidity. Therefore, the dead-time (the de-energization duration of the faulty phase) is unpredictable. Accordingly, conservatively long dead-times are usually considered by protection engineers. However, if the exact arc distinction time is determined, the power system stability and quality will enhance. Therefore, a new method for detection of arc extinction times leading to a new ASPAR method utilizing power line carrier (PLC) signals is presented. The efficiency of the proposed ASPAR method is verified through simulations and compared with the existing ASPAR methods. High-sampling measurements are prone to be skewed by the environmental noises and analog-to-digital (A/D) converters quantization errors. Therefore noise-contaminated measurements are the major source of uncertainties and errors in the outcomes of traveling wave-based diagnostic applications. The existing AT-detection methods do not provide enough sensitivity and selectivity at the same time. Therefore, a new AT-detection method based on short-time matrix pencil (STMPM) is developed to accurately detect ATs of the traveling waves with low signal-to-noise (SNR) ratios. As STMPM is based on matrix algebra, it is a challenging to implement this new technique in microprocessor-based fault locators. Hence, a fully recursive and computationally efficient method based on adaptive discrete Kalman filter (ADKF) is introduced for AT-detection, which is proper for microprocessors and able to accomplish accurate AT-detection for online applications such as ultra-high-speed protection. Both proposed AT-detection methods are evaluated based on extensive simulation studies, and the superior outcomes are compared to the existing methods.
Lechner, Matthias; Rieder, Josef
2007-01-01
The theoretical use of mass spectrometric profiling of low-molecular-weight volatile compounds, as one possible method to non-invasively and rapidly diagnose a variety of diseases, such as cancer, infection, and metabolic disorders has greatly raised the profile of this technique over the last ten years. Despite a number of promising results, this technique has not been introduced into common clinical practice yet. The use of mass spectrometric profiling of exhaled air is particularly hampered by various technical problems and basic methodological issues which have only been partially overcome. However, breath analysis aside, recently published studies reveal completely new ideas and concepts on how to establish fast and reliable diagnosis by using this valuable tool. These studies focussed on the headspace screening of various bodily fluids and sample fluids obtained during diagnostic procedures, as well as microbial cell cultures and demonstrated the vast diagnostic potential of this technique in a wide variety of settings, predominantly in vitro. It is the aim of the present review to discuss the most commonly detected low-molecular-weight volatile compounds and to summarize the current potential applications, latest developments and future perspectives of this promising diagnostic approach.
Diagnostic imaging advances in murine models of colitis.
Brückner, Markus; Lenz, Philipp; Mücke, Marcus M; Gohar, Faekah; Willeke, Peter; Domagk, Dirk; Bettenworth, Dominik
2016-01-21
Inflammatory bowel diseases (IBD) such as Crohn's disease and ulcerative colitis are chronic-remittent inflammatory disorders of the gastrointestinal tract still evoking challenging clinical diagnostic and therapeutic situations. Murine models of experimental colitis are a vital component of research into human IBD concerning questions of its complex pathogenesis or the evaluation of potential new drugs. To monitor the course of colitis, to the present day, classical parameters like histological tissue alterations or analysis of mucosal cytokine/chemokine expression often require euthanasia of animals. Recent advances mean revolutionary non-invasive imaging techniques for in vivo murine colitis diagnostics are increasingly available. These novel and emerging imaging techniques not only allow direct visualization of intestinal inflammation, but also enable molecular imaging and targeting of specific alterations of the inflamed murine mucosa. For the first time, in vivo imaging techniques allow for longitudinal examinations and evaluation of intra-individual therapeutic response. This review discusses the latest developments in the different fields of ultrasound, molecularly targeted contrast agent ultrasound, fluorescence endoscopy, confocal laser endomicroscopy as well as tomographic imaging with magnetic resonance imaging, computed tomography and fluorescence-mediated tomography, discussing their individual limitations and potential future diagnostic applications in the management of human patients with IBD.
Visualization and analysis of pulsed ion beam energy density profile with infrared imaging
NASA Astrophysics Data System (ADS)
Isakova, Y. I.; Pushkarev, A. I.
2018-03-01
Infrared imaging technique was used as a surface temperature-mapping tool to characterize the energy density distribution of intense pulsed ion beams on a thin metal target. The technique enables the measuring of the total ion beam energy and the energy density distribution along the cross section and allows one to optimize the operation of an ion diode and control target irradiation mode. The diagnostics was tested on the TEMP-4M accelerator at TPU, Tomsk, Russia and on the TEMP-6 accelerator at DUT, Dalian, China. The diagnostics was applied in studies of the dynamics of the target cooling in vacuum after irradiation and in the experiments with target ablation. Errors caused by the target ablation and target cooling during measurements have been analyzed. For Fluke Ti10 and Fluke Ti400 infrared cameras, the technique can achieve surface energy density sensitivity of 0.05 J/cm2 and spatial resolution of 1-2 mm. The thermal imaging diagnostics does not require expensive consumed materials. The measurement time does not exceed 0.1 s; therefore, this diagnostics can be used for the prompt evaluation of the energy density distribution of a pulsed ion beam and during automation of the irradiation process.
Fourier transform infrared evanescent wave (FTIR-FEW) spectroscopy of tissue
NASA Astrophysics Data System (ADS)
Bruch, Reinhard F.; Sukuta, Sydney; Afanasyeva, Natalia I.; Kolyakov, Sergei F.; Butvina, Leonid N.
1997-05-01
A new Fourier transform infrared fiberoptic evanescent wave (FTIR-FEW) spectroscopy method has been developed for tissue diagnostics in the middle infrared (MIR) wavelength range (3 to 20 micrometers). Specific novel fiberoptical chemical and biological sensors have been studied and used for spectroscopic diagnostic purposes. These nontoxic and nonhygroscopic fiber sensors are characterized by (1) low optical losses (0.05 to 0.2 dB/m at about 10 micrometer) and (2) high flexibility. Our new fiber optical devices can be utilized with standard commercially available Fourier transform spectrometers including attenuated total reflection (ATR) techniques. They are in particular ideally suited for noninvasive, fast, direct, sensitive investigations of in vivo and ex vivo medical diagnostics applications. Here we present data on IR spectra of skin tissue in vivo for various cases of melanoma and nevus in the range of 1480 - 1800 cm-1. The interpretation of the spectra of healthy and different stages of tumor and cancer skin tissue clearly indicates that this technique can be used for precancer and cancer diagnostics. This technique can be designed for real-time and on-line computer modeling and analysis of tissue changes.
Tsalik, Ephraim L.; Petzold, Elizabeth; Kreiswirth, Barry N.; Bonomo, Robert A.; Banerjee, Ritu; Lautenbach, Ebbing; Evans, Scott R.; Hanson, Kimberly E.; Klausner, Jeffrey D.
2017-01-01
Abstract Diagnostics are a cornerstone of the practice of infectious diseases. However, various limitations frequently lead to unmet clinical needs. In most other domains, diagnostics focus on narrowly defined questions, provide readily interpretable answers, and use true gold standards for development. In contrast, infectious diseases diagnostics must contend with scores of potential pathogens, dozens of clinical syndromes, emerging pathogens, rapid evolution of existing pathogens and their associated resistance mechanisms, and the absence of gold standards in many situations. In spite of these challenges, the importance and value of diagnostics cannot be underestimated. Therefore, the Antibacterial Resistance Leadership Group has identified diagnostics as 1 of 4 major areas of emphasis. Herein, we provide an overview of that development, highlighting several examples where innovation in study design, content, and execution is advancing the field of infectious diseases diagnostics. PMID:28350903
A Framework to Debug Diagnostic Matrices
NASA Technical Reports Server (NTRS)
Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann
2013-01-01
Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.
Space Shuttle main engine OPAD: The search for a hardware enhanced plume
NASA Astrophysics Data System (ADS)
Powers, W. T.; Cooper, A. E.; Wallace, Tim L.; Buntine, W. L.; Whitaker, K. W.
1993-11-01
The process of applying spectroscopy to the Space Shuttle Main Engine (SSME) for plume diagnostics, as it exists today, originated at Marshall Space Flight Center in Huntsville, Alabama, and its implementation was assured largely through the efforts of Sverdrup AEDC, in Tullahoma, Tennessee. This team continues to lead and guide efforts in the plume diagnostics arena. The process, Optical Plume Anomaly Detection (OPAD), formed the basis for various activities in the development of ground-based systems as well as the development of in-flight plume spectroscopy. OPAD currently provides and will continue to provide valuable information relative to future systems definitions, instrumentation development, code validation, and data diagnostic processing. OPAD is based on the detection of anomalous atomic and molecular species in the SSME plume using two complete, stand-alone optical spectrometers. To-date OPAD has acquired data on 44 test firings of the SSME at the Technology Test Bed (TTB) at MSFC. The purpose of this paper will be to provide an introduction to the OPAD system by discussing the process of obtaining data as well as the methods of examining and interpreting the data. It will encompass such issues as selection of instrumentation correlation of data to nominal engine operation, investigation of SSME component erosion via OPAD spectral data, necessity and benefits of plume seeding, application of artificial intelligence (AI) techniques to data analysis, and the present status of efforts to quantify specie erosion utilizing standard plume and chemistry codes as well as radiative models currently under development.
Space Shuttle main engine OPAD: The search for a hardware enhanced plume
NASA Technical Reports Server (NTRS)
Powers, W. T.; Cooper, A. E.; Wallace, Tim L.; Buntine, W. L.; Whitaker, K. W.
1993-01-01
The process of applying spectroscopy to the Space Shuttle Main Engine (SSME) for plume diagnostics, as it exists today, originated at Marshall Space Flight Center in Huntsville, Alabama, and its implementation was assured largely through the efforts of Sverdrup AEDC, in Tullahoma, Tennessee. This team continues to lead and guide efforts in the plume diagnostics arena. The process, Optical Plume Anomaly Detection (OPAD), formed the basis for various activities in the development of ground-based systems as well as the development of in-flight plume spectroscopy. OPAD currently provides and will continue to provide valuable information relative to future systems definitions, instrumentation development, code validation, and data diagnostic processing. OPAD is based on the detection of anomalous atomic and molecular species in the SSME plume using two complete, stand-alone optical spectrometers. To-date OPAD has acquired data on 44 test firings of the SSME at the Technology Test Bed (TTB) at MSFC. The purpose of this paper will be to provide an introduction to the OPAD system by discussing the process of obtaining data as well as the methods of examining and interpreting the data. It will encompass such issues as selection of instrumentation correlation of data to nominal engine operation, investigation of SSME component erosion via OPAD spectral data, necessity and benefits of plume seeding, application of artificial intelligence (AI) techniques to data analysis, and the present status of efforts to quantify specie erosion utilizing standard plume and chemistry codes as well as radiative models currently under development.
Meneghini, Orso; Volpe, Francesco A.
2016-08-19
An innovative millimeter wave diagnostic is proposed to measure the local magnetic field and edge current as a function of the minor radius in the tokamak pedestal region. The idea is to identify the direction of minimum reflectivity at the O-mode cutoff layer. Correspondingly, the transmissivity due to O-X mode conversion is maximum. That direction, and the angular map of reflectivity around it, contain information on the magnetic field vector B at the cutoff layer. By probing the plasma with different wave frequencies it provides the radial profile of B. Full-wave finite-element simulations are presented here in 2D slab geometry.more » Modeling confirms the existence of a minimum in reflectivity that depends on the magnetic field at the cutoff, as expected from mode conversion physics, giving confidence in the feasibility of the diagnostic. We proposed an reflectometric approach in order to yield superior signal-to-noise ratio and to access wider ranges of density and magnetic field, compared with related radiometric techniques that require the plasma to emit Electron Bernstein Waves. Due to computational limitations, frequencies of 10-20 GHz were considered in this initial study. Furthermore, frequencies above the edge electron-cyclotron frequency (f >28 GHz here) would be preferable for the experiment, because the upper hybrid resonance and right cutoff would lie in the plasma, and would help separate the O-mode of interest from spurious X-waves.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meneghini, Orso; Volpe, Francesco A., E-mail: fvolpe@columbia.edu
An innovative millimeter wave diagnostic is proposed to measure the local magnetic field and edge current as a function of the minor radius in the tokamak pedestal region. The idea is to identify the direction of minimum reflectivity at the O-mode cutoff layer. Correspondingly, the transmissivity due to O-X mode conversion is maximum. That direction, and the angular map of reflectivity around it, contains information on the magnetic field vector B at the cutoff layer. Probing the plasma with different wave frequencies provides the radial profile of B. Full-wave finite-element simulations are presented here in 2D slab geometry. Modeling confirmsmore » the existence of a minimum in reflectivity that depends on the magnetic field at the cutoff, as expected from mode conversion physics, giving confidence in the feasibility of the diagnostic. The proposed reflectometric approach is expected to yield superior signal-to-noise ratio and to access wider ranges of density and magnetic field, compared with related radiometric techniques that require the plasma to emit electron Bernstein waves. Due to computational limitations, frequencies of 10-20 GHz were considered in this initial study. Frequencies above the edge electron-cyclotron frequency (f > 28 GHz here) would be preferable for the experiment, because the upper hybrid resonance and right cutoff would lie in the plasma, and would help separate the O-mode of interest from spurious X-waves.« less
Multispectral optical tweezers for molecular diagnostics of single biological cells
NASA Astrophysics Data System (ADS)
Butler, Corey; Fardad, Shima; Sincore, Alex; Vangheluwe, Marie; Baudelet, Matthieu; Richardson, Martin
2012-03-01
Optical trapping of single biological cells has become an established technique for controlling and studying fundamental behavior of single cells with their environment without having "many-body" interference. The development of such an instrument for optical diagnostics (including Raman and fluorescence for molecular diagnostics) via laser spectroscopy with either the "trapping" beam or secondary beams is still in progress. This paper shows the development of modular multi-spectral imaging optical tweezers combining Raman and Fluorescence diagnostics of biological cells.
Diagnostic Examination for Students Entering Graduate Study in Soil Science.
ERIC Educational Resources Information Center
Loynachan, T. E.
1988-01-01
Reports that students with soil science background performed better on a diagnostic examination; no relationship existed between exam performance and country of origin, degree sought, or undergraduate class quartile. Concludes that exam results, the grade received in a beginning graduate-level course and the cumulative graduate grade-point average…
Model Diagnostics for Bayesian Networks. Research Report. ETS RR-04-17
ERIC Educational Resources Information Center
Sinharay, Sandip
2004-01-01
Assessing fit of psychometric models has always been an issue of enormous interest, but there exists no unanimously agreed upon item fit diagnostic for the models. Bayesian networks, frequently used in educational assessments (see, for example, Mislevy, Almond, Yan, & Steinberg, 2001) primarily for learning about students' knowledge and…
Conduct Disorder in Girls: Diagnostic and Intervention Issues
ERIC Educational Resources Information Center
Delligatti, Nina; Akin-Little, Angeleque; Little, Steven G.
2003-01-01
Current prevalence rates of Conduct Disorder (CD) in girls may be an underestimate due to inappropriate diagnostic criteria, biased perceptions by those responsible for reporting problematic behavior, and differential social constraints for each gender. Relatively few published studies of CD and related behaviors in girls exist. Available evidence…
Diagnostic approach to patients with suspected pulmonary embolism: a report from the real world
Saro, G; Campo, J; Hernandez, M; Anta, M; Olmos, J; Gonzalez-Macias, J; Riancho, J
1999-01-01
This study was carried out to examine the diagnostic approach to patients with suspected pulmonary embolism (PE) in a university hospital. A retrospective case record review of 251 patients with suspected pulmonary embolism was carried out according to a standard protocol, which looked at the utilisation of imaging techniques and compared clinical diagnoses with a standardised diagnosis established according to current recommendations. Isotopic lung scan was the most commonly used technique (73%), followed by leg vein sonography (36%) and contrast venography (31%). Lung arteriography was done in only 7% of patients. Among the 205 patients with a clinical diagnosis of PE, 115 (56%) would be diagnosed as having PE according to the standard criteria, 84 (41%) would be unclassified, and six (3%) would not be regarded as having PE. Among patients who were diagnosed as having PE and received anticoagulant therapy, 32% did not have the diagnosis confirmed by an imaging technique. Most of these had a non-diagnostic lung scan which, despite evidence to the contrary, seemed to be interpreted as confirmation of PE. We conclude that clinicians do not seem to follow current recommendations when approaching patients with suspected PE. In particular, there is an over-reliance on lung scans, and the significance of non-diagnostic scans was often misinterpreted. Arteriography was underused. These results emphasise the need to take measures to implement practice guidelines and to explore the usefulness of newer non-invasive techniques. Keywords: pulmonary embolism; diagnosis; lung scan; imaging techniques; audit PMID:10533633
Rahman, Zia Ur; Sethi, Pooja; Murtaza, Ghulam; Virk, Hafeez Ul Hassan; Rai, Aitzaz; Mahmod, Masliza; Schoondyke, Jeffrey; Albalbissi, Kais
2017-01-01
Cardiovascular disease is a leading cause of morbidity and mortality globally. Early diagnostic markers are gaining popularity for better patient care disease outcomes. There is an increasing interest in noninvasive cardiac imaging biomarkers to diagnose subclinical cardiac disease. Feature tracking cardiac magnetic resonance imaging is a novel post-processing technique that is increasingly being employed to assess global and regional myocardial function. This technique has numerous applications in structural and functional diagnostics. It has been validated in multiple studies, although there is still a long way to go for it to become routine standard of care. PMID:28515849
Diagnostic molecular microbiology: a 2013 snapshot.
Fairfax, Marilynn Ransom; Salimnia, Hossein
2013-12-01
Molecular testing has a large and increasing role in the diagnosis of infectious diseases. It has evolved significantly since the first probe tests were FDA approved in the early 1990s. This article highlights the uses of molecular techniques in diagnostic microbiology, including "older," as well as innovative, probe techniques, qualitative and quantitative RT-PCR, highly multiplexed PCR panels, some of which use sealed microfluidic test cartridges, MALDI TOF, and nuclear magnetic resonance. Tests are grouped together by technique and target. Tests with similar roles for similar analytes are compared with respect to benefits, drawbacks, and possible problems. Copyright © 2013 Elsevier Inc. All rights reserved.
Using Standardized Lexicons for Report Template Validation with LexMap, a Web-based Application.
Hostetter, Jason; Wang, Kenneth; Siegel, Eliot; Durack, Jeremy; Morrison, James J
2015-06-01
An enormous amount of data exists in unstructured diagnostic and interventional radiology reports. Free text or non-standardized terminologies limit the ability to parse, extract, and analyze these report data elements. Medical lexicons and ontologies contain standardized terms for relevant concepts including disease entities, radiographic technique, and findings. The use of standardized terms offers the potential to improve reporting consistency and facilitate computer analysis. The purpose of this project was to implement an interface to aid in the creation of standards-compliant reporting templates for use in interventional radiology. Non-standardized procedure report text was analyzed and referenced to RadLex, SNOMED-CT, and LOINC. Using JavaScript, a web application was developed which determined whether exact terms or synonyms in reports existed within these three reference resources. The NCBO BioPortal Annotator web service was used to map terms, and output from this application was used to create an interactive annotated version of the original report. The application was successfully used to analyze and modify five distinct reports for the Society of Interventional Radiology's standardized reporting project.
Surmacki, Piotr; Sporny, Stanisław; Tosiak, Arkadiusz; Lasota, Janusz
2005-12-01
The authors present an exceptional case of a transitional cell carcinoma of the uterine tube in a 59-year-old female patient, co-existing with appendicitis. Originally, the patient was assigned to surgery due to an inflamed tumour of the right adnexa. A mid-surgery diagnose revealed appendicitis by chance, but in the course of an examination of the right uterine tube, performed on the spot, no progressive carcinoid process was univocally diagnosed. Therefore, the treatments applied were a bilateral salpingectomy and appendectomy. In the course of the final pathomorphological examination, using an immunohistochemical technique, a primary cancer of the uterine tube composed of transitional epithelium cells (transitional cell carcinoma G-2, pT1a) was diagnosed. At the time of the second surgery, a radical hysterectomy, bilateral oophorectomy and omentectomy were performed and afterwards, the patient was treated with a post-operational radiotherapy. The authors support the thesis that a primary cancer of the uterine tube may, as it looks, suggest a different ailment and present diagnostic problems.
High-throughput screening technologies for botulinum neurotoxins.
Bompiani, Kristin M; Dickerson, Tobin J
2014-01-01
Botulinum neurotoxins (BoNTs) are a class of bacterial neurotoxins that are the most potent toxic compounds reported to date. Exposure to relatively low concentrations of the toxin protein can result in major muscle paralysis, which may result in death in severe cases. In addition to their role in natural human disease, BoNTs are currently under close scrutiny because of their potential to be used as biowarfare agents. Clinical treatment options for botulism are currently limited, and finite stockpiles of antitoxin exist. In light of current bioterrorist threats, researchers have focused on identifying new molecules that can be applied to either sensitive toxin detection or improved clinical treatment. High-throughput screening (HTS) is a laboratory technique commonly employed to screen large libraries of diverse compounds based on specific compound binding capabilities or function. Here we review existing HTS platforms that have been applied to identify novel BoNT diagnostic or therapeutic agents. HTS platforms for screening antibodies, peptides, small molecules, and aptamers are described, as well as the screening results and current progress of the identified compounds.
Photonic crystals: emerging biosensors and their promise for point-of-care applications.
Inan, Hakan; Poyraz, Muhammet; Inci, Fatih; Lifson, Mark A; Baday, Murat; Cunningham, Brian T; Demirci, Utkan
2017-01-23
Biosensors are extensively employed for diagnosing a broad array of diseases and disorders in clinical settings worldwide. The implementation of biosensors at the point-of-care (POC), such as at primary clinics or the bedside, faces impediments because they may require highly trained personnel, have long assay times, large sizes, and high instrumental cost. Thus, there exists a need to develop inexpensive, reliable, user-friendly, and compact biosensing systems at the POC. Biosensors incorporated with photonic crystal (PC) structures hold promise to address many of the aforementioned challenges facing the development of new POC diagnostics. Currently, PC-based biosensors have been employed for detecting a variety of biotargets, such as cells, pathogens, proteins, antibodies, and nucleic acids, with high efficiency and selectivity. In this review, we provide a broad overview of PCs by explaining their structures, fabrication techniques, and sensing principles. Furthermore, we discuss recent applications of PC-based biosensors incorporated with emerging technologies, including telemedicine, flexible and wearable sensing, smart materials and metamaterials. Finally, we discuss current challenges associated with existing biosensors, and provide an outlook for PC-based biosensors and their promise at the POC.
PROPELLER technique to improve image quality of MRI of the shoulder.
Dietrich, Tobias J; Ulbrich, Erika J; Zanetti, Marco; Fucentese, Sandro F; Pfirrmann, Christian W A
2011-12-01
The purpose of this article is to evaluate the use of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique for artifact reduction and overall image quality improvement for intermediate-weighted and T2-weighted MRI of the shoulder. One hundred eleven patients undergoing MR arthrography of the shoulder were included. A coronal oblique intermediate-weighted turbo spin-echo (TSE) sequence with fat suppression and a sagittal oblique T2-weighted TSE sequence with fat suppression were obtained without (standard) and with the PROPELLER technique. Scanning time increased from 3 minutes 17 seconds to 4 minutes 17 seconds (coronal oblique plane) and from 2 minutes 52 seconds to 4 minutes 10 seconds (sagittal oblique) using PROPELLER. Two radiologists graded image artifacts, overall image quality, and delineation of several anatomic structures on a 5-point scale (5, no artifact, optimal diagnostic quality; and 1, severe artifacts, diagnostically not usable). The Wilcoxon signed rank test was used to compare the data of the standard and PROPELLER images. Motion artifacts were significantly reduced in PROPELLER images (p < 0.001). Observer 1 rated motion artifacts with diagnostic impairment in one patient on coronal oblique PROPELLER images compared with 33 patients on standard images. Ratings for the sequences with PROPELLER were significantly better for overall image quality (p < 0.001). Observer 1 noted an overall image quality with diagnostic impairment in nine patients on sagittal oblique PROPELLER images compared with 23 patients on standard MRI. The PROPELLER technique for MRI of the shoulder reduces the number of sequences with diagnostic impairment as a result of motion artifacts and increases image quality compared with standard TSE sequences. PROPELLER sequences increase the acquisition time.
NASA Astrophysics Data System (ADS)
Kolyakov, Sergei; Afanasyeva, Natalia; Bruch, Reinhard; Afanasyeva, Natalia
1998-05-01
The new method of fiber optical evanescent wave Fourier transform infrared (FEW-FTIR) spectroscopy has been applied to the diagnostics of normal skin tissue, as well as precancerous and cancerous conditions. The FEW-FTIR technique is nondestructive and sensitive to changes of vibrational spectra in the IR region, without heating and damaging human and animal skin tissue. Therefore this method and technique is an ideal diagnostic tool for tumor and cancer characterization at an early stage of development on a molecular level. The application of fiber optic technology in the middle infrared (MIR) region is relatively inexpensive and can be adapted easily to any commercially available tabletop FTIR spectrometers. This method of diagnostics is fast (several seconds), and can be applied to many fields. Noninvasive medical diagnostics of skin cancer and other skin diseases in vivo, ex vivo, and in vitro allow for the development of convenient, remote clinical applications in dermatology and related fields. The spectral variations from normal to pathological skin tissue and environmental influence on skin have been measured.
The Buffer Diagnostic Prototype: A fault isolation application using CLIPS
NASA Technical Reports Server (NTRS)
Porter, Ken
1994-01-01
This paper describes problem domain characteristics and development experiences from using CLIPS 6.0 in a proof-of-concept troubleshooting application called the Buffer Diagnostic Prototype. The problem domain is a large digital communications subsystems called the real-time network (RTN), which was designed to upgrade the launch processing system used for shuttle support at KSC. The RTN enables up to 255 computers to share 50,000 data points with millisecond response times. The RTN's extensive built-in test capability but lack of any automatic fault isolation capability presents a unique opportunity for a diagnostic expert system application. The Buffer Diagnostic Prototype addresses RTN diagnosis with a multiple strategy approach. A novel technique called 'faulty causality' employs inexact qualitative models to process test results. Experimental knowledge provides a capability to recognize symptom-fault associations. The implementation utilizes rule-based and procedural programming techniques, including a goal-directed control structure and simple text-based generic user interface that may be reusable for other rapid prototyping applications. Although limited in scope, this project demonstrates a diagnostic approach that may be adapted to troubleshoot a broad range of equipment.
NASA Astrophysics Data System (ADS)
Li, Shaoxin; Zhang, Yanjiao; Xu, Junfa; Li, Linfang; Zeng, Qiuyao; Lin, Lin; Guo, Zhouyi; Liu, Zhiming; Xiong, Honglian; Liu, Songhao
2014-09-01
This study aims to present a noninvasive prostate cancer screening methods using serum surface-enhanced Raman scattering (SERS) and support vector machine (SVM) techniques through peripheral blood sample. SERS measurements are performed using serum samples from 93 prostate cancer patients and 68 healthy volunteers by silver nanoparticles. Three types of kernel functions including linear, polynomial, and Gaussian radial basis function (RBF) are employed to build SVM diagnostic models for classifying measured SERS spectra. For comparably evaluating the performance of SVM classification models, the standard multivariate statistic analysis method of principal component analysis (PCA) is also applied to classify the same datasets. The study results show that for the RBF kernel SVM diagnostic model, the diagnostic accuracy of 98.1% is acquired, which is superior to the results of 91.3% obtained from PCA methods. The receiver operating characteristic curve of diagnostic models further confirm above research results. This study demonstrates that label-free serum SERS analysis technique combined with SVM diagnostic algorithm has great potential for noninvasive prostate cancer screening.
Dorsolateral Frontal Lobe Epilepsy
Lee, Ricky W.; Worrell, Greg A.
2012-01-01
Dorsolateral frontal lobe seizures often present as a diagnostic challenge. The diverse semiologies may not produce lateralizing or localizing signs, and can appear bizarre and suggest psychogenic events. Unfortunately, scalp EEG and MRI are often unsatisfactory. It is not uncommon that these traditional diagnostic studies are either unhelpful or even misleading. In some cases SPECT and PET imaging can be an effective tool to identify the origin of seizures. However, these techniques and other emerging techniques all have limitations, and new approaches are needed to improve source localization. PMID:23027094
Characterization of the spectral phase of an intense laser at focus via ionization blueshift
Mittelberger, D. E.; Nakamura, K.; Lehe, R.; ...
2016-01-01
An in situ diagnostic for verifying the spectral phase of an intense laser pulse at focus is shown. This diagnostic relies on measuring the effect of optical compression on ionization-induced blueshifting of the laser spectrum. Experimental results from the Berkeley Lab Laser Accelerator, a laser source rigorously characterized by conventional techniques, are presented and compared with simulations to illustrate the utility of this technique. These simulations show distinguishable effects from second-, third-, and fourth-order spectral phase.
Development of Optimized Combustors and Thermoelectric Generators for Palm Power Generation
2004-10-26
manufacturing techniques and microfabrication, on the chemical kinetics of JP-8 surrogates and on the development of advanced laser diagnostics for JP-8...takes the shape of a cone from the tip of which a thin liquid thread emerges, in the so-called cone-jet mode [1]. This microjet breaks into a stream of...combustion systems. 2. The development of a diagnostic technique based on two-color laser induced fluorescence from fluorescence tags added to the fuel
Electric Vehicle Service Personnel Training Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernstein, Gerald
As the share of hybrid, plug-in hybrid (PHEV), electric (EV) and fuel-cell (FCV) vehicles grows in the national automotive fleet, an entirely new set of diagnostic and technical skills needs to be obtained by the maintenance workforce. Electrically-powered vehicles require new diagnostic tools, technique and vocabulary when compared to existing internal combustion engine-powered models. While the manufacturers of these new vehicles train their own maintenance personnel, training for students, independent working technicians and fleet operators is less focused and organized. This DOE-funded effort provided training to these three target groups to help expand availability of skills and to provide moremore » competition (and lower consumer cost) in the maintenance of these hybrid- and electric-powered vehicles. Our approach was to start locally in the San Francisco Bay Area, one of the densest markets in the United States for these types of automobiles. We then expanded training to the Los Angeles area and then out-of-state to identify what types of curriculum was appropriate and what types of problems were encountered as training was disseminated. The fact that this effort trained up to 800 individuals with sessions varying from 2- day workshops to full-semester courses is considered a successful outcome. Diverse programs were developed to match unique time availability and educational needs of each of the three target audiences. Several key findings and observations arising from this effort include: • Recognition that hybrid and PHEV training demand is immediate; demand for EV training is starting to emerge; while demand for FCV training is still over the horizon • Hybrid and PHEV training are an excellent starting point for all EV-related training as they introduce all the basic concepts (electric motors, battery management, controllers, vocabulary, testing techniques) that are needed for all EVs, and these skills are in-demand in today’s market. • Faculty training is widely available and can be relatively quickly achieved. Equipment availability (vehicles, specialized tools, diagnostic software and computers) is a bigger challenge for funding-constrained colleges. • A computer-based emulation system that would replicate vehicle and diagnostic software in one package is a training aid that would have widespread benefit, but does not appear to exist. This need is further described at the end of Section 6.5. The benefits of this project are unique to each of the three target audiences. Students have learned skills they will use for the remainder of their careers; independent technicians can now accept customers who they previously needed to turn away due to lack of familiarity with hybrid systems; and fleet maintenance personnel are able to lower costs by undertaking work in-house that they previously needed to outsource. The direct job impact is estimated at 0.75 FTE continuously over the 3 ½ -year duration of the grant.« less
Single cell Enrichment with High Throughput Microfluidic Devices
NASA Astrophysics Data System (ADS)
Pakjesm Pourfard, Pedram
Microfluidics is a rapidly growing field of biomedical engineering with numerous applications such as diagnostic testing, therapeutics, and research preparation. Cell enrichment for automated diagnostic is often assayed through measurement of biochemical and biophysical markers. Although biochemical markers have been widely used, intrinsic biophysical markers, such as, Shear migration, Lift force, Dean force, and many other label-free techniques, are advantageous since they don't require costly labeling or sample preparation. However, current passive techniques for enrichment had limited adoption in clinical and cell biology research applications. They generally require low flow rate and low cell volume fraction for high efficiency. The Control increment filtration, T-shaped microfluidic device, and spiral-shaped microfluidic devices will be studied for single-cell separation from aggregates. Control increment filtration works like the tangential filter; however, cells are separated based off of same amount of flow rate passing through large space gaps. Main microchannel of T-Shaped is connected to two perpendicular side channels. Based off Shear-modulated inertial migration, this device will enable selective enrichment of cells. The spiral shaped microfluidic device depends on different Dean and lift forces acting on cells to separate them based off different sizes. The spiral geometry of the microchannel will enable dominant inertial forces and the Dean Rotation force to cause larger cells to migrate to the inner side of the microchannel. Because manipulation of microchannel dimensions correlates to the degree of cell separation, versatility in design exists. Cell mixture samples will contain cells of different sizes and therefore design strategies could be utilized to maximize the effectiveness of single-cell separation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, Chirag; Vicini, Frank A., E-mail: fvicini@beaumont.edu
As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer-related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially withmore » a range of 2-65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.« less
Gilman, Robert H; Tielsch, James M; Steinhoff, Mark; Figueroa, Dante; Rodriguez, Shalim; Caffo, Brian; Tracey, Brian; Elhilali, Mounya; West, James; Checkley, William
2012-01-01
Introduction WHO case management algorithm for paediatric pneumonia relies solely on symptoms of shortness of breath or cough and tachypnoea for treatment and has poor diagnostic specificity, tends to increase antibiotic resistance. Alternatives, including oxygen saturation measurement, chest ultrasound and chest auscultation, exist but with potential disadvantages. Electronic auscultation has potential for improved detection of paediatric pneumonia but has yet to be standardised. The authors aim to investigate the use of electronic auscultation to improve the specificity of the current WHO algorithm in developing countries. Methods This study is designed to test the hypothesis that pulmonary pathology can be differentiated from normal using computerised lung sound analysis (CLSA). The authors will record lung sounds from 600 children aged ≤5 years, 100 each with consolidative pneumonia, diffuse interstitial pneumonia, asthma, bronchiolitis, upper respiratory infections and normal lungs at a children's hospital in Lima, Peru. The authors will compare CLSA with the WHO algorithm and other detection approaches, including physical exam findings, chest ultrasound and microbiologic testing to construct an improved algorithm for pneumonia diagnosis. Discussion This study will develop standardised methods for electronic auscultation and chest ultrasound and compare their utility for detection of pneumonia to standard approaches. Utilising signal processing techniques, the authors aim to characterise lung sounds and through machine learning, develop a classification system to distinguish pathologic sounds. Data will allow a better understanding of the benefits and limitations of novel diagnostic techniques in paediatric pneumonia. PMID:22307098
Thomassin-Naggara, I; Bendifallah, S; Rousset, P; Bazot, M; Ballester, M; Darai, E
2018-03-01
Diagnostic performance of MR imaging for the diagnosis of pelvic endometriosis are good. Even if some differences of performances exists according the location considered, the risk of misdiagnosis is lower than 10% for trained teams (NP2). The performance of pelvic MR imaging and surgery are quite similar to diagnose endometrioma (sensitivity and specificity>90%). A negative pelvic MR imaging allows to exclude deep pelvic endometriosis with a performance similar to surgery but a positive MR imaging is less accurate than surgery because of a high number of false positives (23%). Pelvic MR imaging is more sensitive and less specific than ultrasonography for the diagnosis of uterosacral ligament, vagina or recto vaginal septum (NP2). Pelvic ultrasonography is more sensitive than pelvic MR imaging for the diagnosis of colorectal location (NP3). Pelvic MR imaging is a reproducible technique for the diagnosis of pelvic endometriosis (NP3). Regarding, quality criteria of pelvic MR imaging, no data are enough to recommend a specific MR unit, digestive preparation, or a specific moment during the menstrual cycle to realize the examination. Vaginal and/or rectal opacification are options. Most of studies are based a protocol including 3D T2W and 3DT1W sequences. Gadolinium injection is useful to characterize a complex adnexal mass. In clinical routine, slices crossing the kidneys are useful to evaluate the presence of pyelo calic distension. ColoCT is an accurate technique to diagnose pelvic digestive endometriosis (rectosigmoide and iléocaecal) (NP3). Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Backscatter factors and mass energy-absorption coefficient ratios for diagnostic radiology dosimetry
NASA Astrophysics Data System (ADS)
Benmakhlouf, Hamza; Bouchard, Hugo; Fransson, Annette; Andreo, Pedro
2011-11-01
Backscatter factors, B, and mass energy-absorption coefficient ratios, (μen/ρ)w, air, for the determination of the surface dose in diagnostic radiology were calculated using Monte Carlo simulations. The main purpose was to extend the range of available data to qualities used in modern x-ray techniques, particularly for interventional radiology. A comprehensive database for mono-energetic photons between 4 and 150 keV and different field sizes was created for a 15 cm thick water phantom. Backscattered spectra were calculated with the PENELOPE Monte Carlo system, scoring track-length fluence differential in energy with negligible statistical uncertainty; using the Monte Carlo computed spectra, B factors and (μen/ρ)w, air were then calculated numerically for each energy. Weighted averaging procedures were subsequently used to convolve incident clinical spectra with mono-energetic data. The method was benchmarked against full Monte Carlo calculations of incident clinical spectra obtaining differences within 0.3-0.6%. The technique used enables the calculation of B and (μen/ρ)w, air for any incident spectrum without further time-consuming Monte Carlo simulations. The adequacy of the extended dosimetry data to a broader range of clinical qualities than those currently available, while keeping consistency with existing data, was confirmed through detailed comparisons. Mono-energetic and spectra-averaged values were compared with published data, including those in ICRU Report 74 and IAEA TRS-457, finding average differences of 0.6%. Results are provided in comprehensive tables appropriated for clinical use. Additional qualities can easily be calculated using a designed GUI interface in conjunction with software to generate incident photon spectra.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorman, A; Seabrook, G; Brakken, A
Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6.more » They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles.« less
Duraipandian, Shiyamala; Sylvest Bergholt, Mads; Zheng, Wei; Yu Ho, Khek; Teh, Ming; Guan Yeoh, Khay; Bok Yan So, Jimmy; Shabbir, Asim; Huang, Zhiwei
2012-08-01
Optical spectroscopic techniques including reflectance, fluorescence and Raman spectroscopy have shown promising potential for in vivo precancer and cancer diagnostics in a variety of organs. However, data-analysis has mostly been limited to post-processing and off-line algorithm development. In this work, we develop a fully automated on-line Raman spectral diagnostics framework integrated with a multimodal image-guided Raman technique for real-time in vivo cancer detection at endoscopy. A total of 2748 in vivo gastric tissue spectra (2465 normal and 283 cancer) were acquired from 305 patients recruited to construct a spectral database for diagnostic algorithms development. The novel diagnostic scheme developed implements on-line preprocessing, outlier detection based on principal component analysis statistics (i.e., Hotelling's T2 and Q-residuals) for tissue Raman spectra verification as well as for organ specific probabilistic diagnostics using different diagnostic algorithms. Free-running optical diagnosis and processing time of < 0.5 s can be achieved, which is critical to realizing real-time in vivo tissue diagnostics during clinical endoscopic examination. The optimized partial least squares-discriminant analysis (PLS-DA) models based on the randomly resampled training database (80% for learning and 20% for testing) provide the diagnostic accuracy of 85.6% [95% confidence interval (CI): 82.9% to 88.2%] [sensitivity of 80.5% (95% CI: 71.4% to 89.6%) and specificity of 86.2% (95% CI: 83.6% to 88.7%)] for the detection of gastric cancer. The PLS-DA algorithms are further applied prospectively on 10 gastric patients at gastroscopy, achieving the predictive accuracy of 80.0% (60/75) [sensitivity of 90.0% (27/30) and specificity of 73.3% (33/45)] for in vivo diagnosis of gastric cancer. The receiver operating characteristics curves further confirmed the efficacy of Raman endoscopy together with PLS-DA algorithms for in vivo prospective diagnosis of gastric cancer. This work successfully moves biomedical Raman spectroscopic technique into real-time, on-line clinical cancer diagnosis, especially in routine endoscopic diagnostic applications.
NASA Astrophysics Data System (ADS)
Duraipandian, Shiyamala; Sylvest Bergholt, Mads; Zheng, Wei; Yu Ho, Khek; Teh, Ming; Guan Yeoh, Khay; Bok Yan So, Jimmy; Shabbir, Asim; Huang, Zhiwei
2012-08-01
Optical spectroscopic techniques including reflectance, fluorescence and Raman spectroscopy have shown promising potential for in vivo precancer and cancer diagnostics in a variety of organs. However, data-analysis has mostly been limited to post-processing and off-line algorithm development. In this work, we develop a fully automated on-line Raman spectral diagnostics framework integrated with a multimodal image-guided Raman technique for real-time in vivo cancer detection at endoscopy. A total of 2748 in vivo gastric tissue spectra (2465 normal and 283 cancer) were acquired from 305 patients recruited to construct a spectral database for diagnostic algorithms development. The novel diagnostic scheme developed implements on-line preprocessing, outlier detection based on principal component analysis statistics (i.e., Hotelling's T2 and Q-residuals) for tissue Raman spectra verification as well as for organ specific probabilistic diagnostics using different diagnostic algorithms. Free-running optical diagnosis and processing time of < 0.5 s can be achieved, which is critical to realizing real-time in vivo tissue diagnostics during clinical endoscopic examination. The optimized partial least squares-discriminant analysis (PLS-DA) models based on the randomly resampled training database (80% for learning and 20% for testing) provide the diagnostic accuracy of 85.6% [95% confidence interval (CI): 82.9% to 88.2%] [sensitivity of 80.5% (95% CI: 71.4% to 89.6%) and specificity of 86.2% (95% CI: 83.6% to 88.7%)] for the detection of gastric cancer. The PLS-DA algorithms are further applied prospectively on 10 gastric patients at gastroscopy, achieving the predictive accuracy of 80.0% (60/75) [sensitivity of 90.0% (27/30) and specificity of 73.3% (33/45)] for in vivo diagnosis of gastric cancer. The receiver operating characteristics curves further confirmed the efficacy of Raman endoscopy together with PLS-DA algorithms for in vivo prospective diagnosis of gastric cancer. This work successfully moves biomedical Raman spectroscopic technique into real-time, on-line clinical cancer diagnosis, especially in routine endoscopic diagnostic applications.
Aderka, Idan M; Nickerson, Angela; Hofmann, Stefan G
2012-06-01
Much controversy exists regarding diagnostic subtypes of social anxiety disorder (SAD). The present study used admixture analysis to examine whether individuals with generalized and nongeneralized SAD belong to the same or different populations of origin. This can inform diagnostic subtyping of SAD in the forthcoming DSM-V. Treatment-seeking individuals with generalized SAD (n = 154) and nongeneralized SAD (n = 48) completed a battery of questionnaires. Based on participants' responses to the Liebowitz Social Anxiety Scale (LSAS), we estimated log likelihood and chi-square goodness-of-fit for models with 1, 2, 3, or 4 populations of origin, and compared models using forward stepwise estimation and maximum likelihood ratio tests. Admixture analyses suggested that the two diagnostic subtypes of SAD belong to the same underlying population of origin. In addition, observable differences in depression, general anxiety, and comorbidity were no longer significant when controlling for social anxiety severity. Our sample was recruited in the U.S. and was a treatment-seeking sample. Future studies should examine whether our results generalize to different cultures, and community samples. Support for qualitative differences between SAD subtypes was not found. Rather, our findings support the notion that the diagnostic subtypes of SAD differ quantitatively, and that SAD exists on a continuum of severity. This finding informs diagnostic subtyping of SAD in the forthcoming DSM-V. Copyright © 2011 Elsevier Ltd. All rights reserved.
Laser diagnostics for combustion temperature and species
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eckbreth, A.C.
1987-01-01
Laser approaches to combustion diagnostics are of considerable interest due to their remote, nonintrusive and in-situ character, unlimited temperature capability and potential for simultaneous temporal and spatial resolution, This book aims to make these powerful and important new tools in combustion research understandable. The focus of this text is on spectroscopically-based, spatially-precise laser techniques for temperature and chemical composition measurements in reacting and nonreacting flows. After introductory chapters providing a fundamental theoretical and experimental background, attention is directed to diagnostics based upon spontaneous Raman and Rayleigh scattering, coherent anti-Stokes Raman spectroscopy (CARS) and laser-induced fluorescence (LIFS). The book concludes withmore » a treatment of techniques which permit spatially-resolved measurements over an entire two-dimensional field simultaneously.« less
NASA Technical Reports Server (NTRS)
Rinehart, Aidan W.; Simon, Donald L.
2015-01-01
This paper presents a model-based architecture for performance trend monitoring and gas path fault diagnostics designed for analyzing streaming transient aircraft engine measurement data. The technique analyzes residuals between sensed engine outputs and model predicted outputs for fault detection and isolation purposes. Diagnostic results from the application of the approach to test data acquired from an aircraft turbofan engine are presented. The approach is found to avoid false alarms when presented nominal fault-free data. Additionally, the approach is found to successfully detect and isolate gas path seeded-faults under steady-state operating scenarios although some fault misclassifications are noted during engine transients. Recommendations for follow-on maturation and evaluation of the technique are also presented.
NASA Technical Reports Server (NTRS)
Rinehart, Aidan W.; Simon, Donald L.
2014-01-01
This paper presents a model-based architecture for performance trend monitoring and gas path fault diagnostics designed for analyzing streaming transient aircraft engine measurement data. The technique analyzes residuals between sensed engine outputs and model predicted outputs for fault detection and isolation purposes. Diagnostic results from the application of the approach to test data acquired from an aircraft turbofan engine are presented. The approach is found to avoid false alarms when presented nominal fault-free data. Additionally, the approach is found to successfully detect and isolate gas path seeded-faults under steady-state operating scenarios although some fault misclassifications are noted during engine transients. Recommendations for follow-on maturation and evaluation of the technique are also presented.
Loudon, R G
1987-06-01
Accurate diagnosis is essential for effective treatment. After history-taking, the physical examination is second in importance in assessing a pulmonary patient. The time-honored sequence of inspection, palpation, percussion, and auscultation is appropriate. Diagnostic tests are becoming more complex, more expensive, and more inclined to separate the patient and physician. The stethoscope is still the more commonly used diagnostic medical instrument, but it is not always used to best advantage. It is familiar, harmless, portable, and inexpensive. Its appropriate use improves medical practice and reduces costs. Improvements in sound recording and analysis techniques have spurred a renewed interest in lung sounds and their meaning. This is likely to lead to better understanding of what we hear, and perhaps to the development of new noninvasive diagnostic and monitoring techniques.
Thiel, M; Bossart, W; Bernauer, W
1997-01-01
BACKGROUND—For epidemiological and therapeutic reasons early diagnosis of superficial viral infections is crucial. Conventional microbiological techniques are expensive, time consuming, and not sufficiently sensitive. In this study impression cytology techniques were evaluated to analyse their diagnostic potential in viral infections of the ocular surface. METHOD—A Biopore membrane device instead of the original impression cytology technique was used to allow better quality and handling of the specimens. The impressions were processed, using monoclonal antibodies and immunoperoxidase or immunofluorescence techniques to assess the presence of herpes simplex virus, varicella zoster virus, or adenovirus antigens. Ocular surface specimens from healthy individuals (n=10) and from patients with suspected viral surface disease (n=19) were studied. Infected and non-infected cell cultures served as controls. RESULTS—This modified technique of impression cytology allowed the collection of large conjunctival and corneal epithelial cell layers with excellent morphology. Immunocytological staining of these samples provided diagnostic results for all three viruses in patients with viral surface disease. CONCLUSIONS—The use of Biopore membrane devices for the collection of ocular surface epithelia offers new diagnostic possibilities for external eye diseases. Immunopathological methods that are applied directly on these membrane devices can provide virological results within 1-4 hours. This contributes considerably to the clinical management of patients with infectious diseases of the ocular surface. PMID:9505824
Secondary prevention at 360°: the important role of diagnostic imaging.
Ciarrapico, Anna Micaela; Manenti, Guglielmo; Pistolese, Chiara; Fabiano, Sebastiano; Fiori, Roberto; Romagnoli, Andrea; Sergiacomi, Gianluigi; Stefanini, Matteo; Simonetti, Giovanni
2015-06-01
The aim of this paper is to underline the importance of the role of general practitioners (GPs) in distributing vital information about prevention to citizens, to highlight the importance of the so-called voluntary prevention programmes, both for conditions for which no organised screening programmes exist and for those for which they do exist but may well be obsolete or inefficient. Nowadays, voluntary prevention is made more effective thanks to the new sophisticated diagnostic technologies applied worldwide by diagnostic imaging. Epidemiological data about the incidence and causes of death among the Italian population have shown that screening programmes should be aimed first at fighting the following diseases: prostatic carcinoma, lung cancer, colorectal carcinoma, breast cancer, cardiovascular disease, cerebrovascular disease, aortic and peripheral vascular disease. GPs do not generally give good or adequate instructions concerning voluntary prevention programmes; GPs may not even be aware of this type of prevention which could represent a valuable option together with the existing mass screening programmes. Therefore, in the following analysis, we aim to outline the correct diagnostic pathway for the prevention of diseases having the highest incidence in our country and which represent the most frequent causes of death. If used correctly, these screening programmes may contribute to the success of secondary prevention, limiting the use of tertiary prevention and thus producing savings for the Italian National Health System.
Development of Diesel Diagnostics for U.S. Coast Guard Cutters
DOT National Transportation Integrated Search
1981-07-01
This program involved an investigation of techniques to perform engine fuel diagnosis on the large medium-speed diesel engines used as main propulsion power plants in medium- and high-endurance Coast Guard cutters. Two engine diagnostic parameters we...
Current limitations and recommendations to improve testing ...
In this paper existing regulatory frameworks and test systems for assessing potential endocrine-active chemicals are described, and associated challenges discussed, along with proposed approaches to address these challenges. Regulatory frameworks vary somewhat across organizations, but all basically evaluate whether a chemical possesses endocrine activity and whether this activity can result in adverse outcomes either to humans or the environment. Current test systems include in silico, in vitro and in vivo techniques focused on detecting potential endocrine activity, and in vivo tests that collect apical data to detect possible adverse effects. These test systems are currently designed to robustly assess endocrine activity and/or adverse effects in the estrogen, androgen, and thyroid hormonal pathways; however, there are some limitations of current test systems for evaluating endocrine hazard and risk. These limitations include a lack of certainty regarding: 1)adequately sensitive species and life-stages, 2) mechanistic endpoints that are diagnostic for endocrine pathways of concern, and 3) the linkage between mechanistic responses and apical, adverse outcomes. Furthermore, some existing test methods are resource intensive in regard to time, cost, and use of animals. However, based on recent experiences, there are opportunities to improve approaches to, and guidance for existing test methods, and to reduce uncertainty. For example, in vitro high throughput
Mason, Jay W; Hancock, E William; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Josephson, Mark; Kligfield, Paul; Kors, Jan A; Macfarlane, Peter; Pahlm, Olle; Mirvis, David M; Okin, Peter; Rautaharju, Pentti; Surawicz, Borys; van Herpen, Gerard; Wagner, Galen S; Wellens, Hein
2007-03-13
This statement provides a concise list of diagnostic terms for ECG interpretation that can be shared by students, teachers, and readers of electrocardiography. This effort was motivated by the existence of multiple automated diagnostic code sets containing imprecise and overlapping terms. An intended outcome of this statement list is greater uniformity of ECG diagnosis and a resultant improvement in patient care. The lexicon includes primary diagnostic statements, secondary diagnostic statements, modifiers, and statements for the comparison of ECGs. This diagnostic lexicon should be reviewed and updated periodically.
Mason, Jay W; Hancock, E William; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Josephson, Mark; Kligfield, Paul; Kors, Jan A; Macfarlane, Peter; Pahlm, Olle; Mirvis, David M; Okin, Peter; Rautaharju, Pentti; Surawicz, Borys; van Herpen, Gerard; Wagner, Galen S; Wellens, Hein
2007-03-13
This statement provides a concise list of diagnostic terms for ECG interpretation that can be shared by students, teachers, and readers of electrocardiography. This effort was motivated by the existence of multiple automated diagnostic code sets containing imprecise and overlapping terms. An intended outcome of this statement list is greater uniformity of ECG diagnosis and a resultant improvement in patient care. The lexicon includes primary diagnostic statements, secondary diagnostic statements, modifiers, and statements for the comparison of ECGs. This diagnostic lexicon should be reviewed and updated periodically.
Development and use of culture systems to modulate specific cell responses
NASA Astrophysics Data System (ADS)
Martin, Yves
Culture surfaces that induce specific localized cell responses are required to achieve tissue-like cell growth in three-dimensional (3D) environments, as well as to develop more efficient cell-based diagnostic techniques, noticeably when working with fragile cells such as stem cells or platelets. As such, Chapter 1 of this thesis work is devoted to the review of 3D cell-material interactions in vitro and the corresponding existing culture systems available to achieve in vivo-like cell responses. More adequate 3D culture systems will need to be developed to mimic several characteristics of in vivo environments, including lowered non-specific cell-material interactions and localized biochemical signaling. The experimental work in this thesis is based on the hypothesis that well-studied and optimized surface treatments will be able to lower non-specific cell-material interactions and allow local chemical modification in order to achieve specific localized cell-material interactions for different applications. As such, in Chapter 2 and Chapter 3 of this thesis, surface treatments were developed using plasma polymerization and covalent immobilization of a low-fouling polymer (i.e., poly(ethylene glycol)) and characterized and optimized using a large number of techniques including atomic force microscopy, quartz crystal microbalance, surface plasmon resonance, x-ray photoelectron spectroscopy and fluorescence-based techniques. The main plasma polymerization parameter important for surface chemical content, specifically nitrogen to carbon content, was identified as being glow discharge power, while reaction time and power determined plasma film thickness. Moreover, plasma films were shown to be stable in aqueous environments. Covalently-bound poly(ethylene glycol) (PEG) layers physicochemical and mechanical properties are dependent on fabrication methods. Polymer concentration in solution is an important indicator of final layer properties, and use of a theta solvent induces complex aggregation phenomena in solution yielding layers with widely different properties. Chemically available primary amine groups are also shown to be present, paving the way for the immobilization of bio-active molecules. An application of low-fouling locally modified surfaces is given in Chapter 4 by the development of a novel diagnostic surface to evaluate platelet activation which is until now very difficult as platelets are readily activated by in vitro manipulations. Significant results from volunteer donors indicate that this diagnostic instrument has the potential to allow the rapid estimation of platelet activation levels in whole blood.
Namatovu, Alice; Wekesa, Sabenzia Nabalayo; Tjørnehøj, Kirsten; Dhikusooka, Moses Tefula; Muwanika, Vincent B; Siegsmund, Hans Redlef; Ayebazibwe, Chrisostom
2013-01-24
Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006-2010. The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples.
2013-01-01
Background Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006–2010. Results The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. Conclusions This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples. PMID:23347795
Sensor Selection for Aircraft Engine Performance Estimation and Gas Path Fault Diagnostics
NASA Technical Reports Server (NTRS)
Simon, Donald L.; Rinehart, Aidan W.
2015-01-01
This paper presents analytical techniques for aiding system designers in making aircraft engine health management sensor selection decisions. The presented techniques, which are based on linear estimation and probability theory, are tailored for gas turbine engine performance estimation and gas path fault diagnostics applications. They enable quantification of the performance estimation and diagnostic accuracy offered by different candidate sensor suites. For performance estimation, sensor selection metrics are presented for two types of estimators including a Kalman filter and a maximum a posteriori estimator. For each type of performance estimator, sensor selection is based on minimizing the theoretical sum of squared estimation errors in health parameters representing performance deterioration in the major rotating modules of the engine. For gas path fault diagnostics, the sensor selection metric is set up to maximize correct classification rate for a diagnostic strategy that performs fault classification by identifying the fault type that most closely matches the observed measurement signature in a weighted least squares sense. Results from the application of the sensor selection metrics to a linear engine model are presented and discussed. Given a baseline sensor suite and a candidate list of optional sensors, an exhaustive search is performed to determine the optimal sensor suites for performance estimation and fault diagnostics. For any given sensor suite, Monte Carlo simulation results are found to exhibit good agreement with theoretical predictions of estimation and diagnostic accuracies.
Sensor Selection for Aircraft Engine Performance Estimation and Gas Path Fault Diagnostics
NASA Technical Reports Server (NTRS)
Simon, Donald L.; Rinehart, Aidan W.
2016-01-01
This paper presents analytical techniques for aiding system designers in making aircraft engine health management sensor selection decisions. The presented techniques, which are based on linear estimation and probability theory, are tailored for gas turbine engine performance estimation and gas path fault diagnostics applications. They enable quantification of the performance estimation and diagnostic accuracy offered by different candidate sensor suites. For performance estimation, sensor selection metrics are presented for two types of estimators including a Kalman filter and a maximum a posteriori estimator. For each type of performance estimator, sensor selection is based on minimizing the theoretical sum of squared estimation errors in health parameters representing performance deterioration in the major rotating modules of the engine. For gas path fault diagnostics, the sensor selection metric is set up to maximize correct classification rate for a diagnostic strategy that performs fault classification by identifying the fault type that most closely matches the observed measurement signature in a weighted least squares sense. Results from the application of the sensor selection metrics to a linear engine model are presented and discussed. Given a baseline sensor suite and a candidate list of optional sensors, an exhaustive search is performed to determine the optimal sensor suites for performance estimation and fault diagnostics. For any given sensor suite, Monte Carlo simulation results are found to exhibit good agreement with theoretical predictions of estimation and diagnostic accuracies.
Ng-Nguyen, Dinh; Stevenson, Mark A; Dorny, Pierre; Gabriël, Sarah; Vo, Tinh Van; Nguyen, Van-Anh Thi; Phan, Trong Van; Hii, Sze Fui; Traub, Rebecca J
2017-07-01
Taenia solium, the cause of neurocysticercosis (NCC), has significant socioeconomic impacts on communities in developing countries. This disease, along with taeniasis is estimated to infect 2.5 to 5 million people globally. Control of T. solium NCC necessitates accurate diagnosis and treatment of T. solium taeniasis carriers. In areas where all three species of Taenia tapeworms (T. solium, Taenia saginata and Taenia asiatica) occur sympatrically, conventional microscope- and copro-antigen based diagnostic methods are unable to distinguish between these three Taenia species. Molecular diagnostic tools have been developed to overcome this limitation; however, conventional PCR-based techniques remain unsuitable for large-scale deployment in community-based surveys. Moreover, a real-time PCR (qPCR) for the discrimination of all three species of Taenia in human stool does not exist. This study describes the development and validation of a new triplex Taq-Man probe-based qPCR for the detection and discrimination of all three Taenia human tapeworms in human stools collected from communities in the Central Highlands of Vietnam. The diagnostic characteristics of the test are compared with conventional Kato Katz (KK) thick smear and copro-antigen ELISA (cAgELISA) method utilizing fecal samples from a community based cross-sectional study. Using this new multiplex real-time PCR we provide an estimate of the true prevalence of taeniasis in the source population for the community based cross-sectional study. Primers and TaqMan probes for the specific amplification of T. solium, T. saginata and T. asiatica were designed and successfully optimized to target the internal transcribed spacer I (ITS-1) gene of T. solium and the cytochrome oxidase subunit I (COX-1) gene of T. saginata and T. asiatica. The newly designed triplex qPCR (T3qPCR) was compared to KK and cAgELISA for the detection of Taenia eggs in stool samples collected from 342 individuals in Dak Lak province, Central Highlands of Vietnam. The overall apparent prevalence of taeniasis in Dak Lak province was 6.72% (95% confidence interval (CI) [3.94-9.50]) in which T. solium accounted for 1.17% (95% CI [0.37-3.17]), according to the T3qPCR. There was sympatric presence of T. solium, T. saginata and T. asiatica. The T3qPCR proved superior to KK and cAgELISA for the detection and differentiation of Taenia species in human feces. Diagnostic sensitivities of 0.94 (95% credible interval (CrI) [0.88-0.98]), 0.82 (95% CrI [0.58-0.95]) and 0.52 (95% CrI [0.07-0.94]), and diagnostic specificities of 0.98 (95% CrI [0.94-1.00]), 0.91 (95% CrI [0.85-0.96]) and 0.99 (95% CrI [0.96-1.00]) were estimated for the diagnosis of taeniasis for the T3qPCR, cAgELISA and KK thick smear in this study, respectively. T3qPCR is not only superior to the KK thick smear and cAgELISA in terms of diagnostic sensitivity and specificity, but it also has the advantage of discriminating between species of Taenia eggs in stools. Application of this newly developed T3qPCR has identified the existence of all three human Taenia tapeworms in Dak Lak province and proves for the first time, the existence of T. asiatica in the Central Highlands and the south of Vietnam.
Microbiome and pancreatic cancer: A comprehensive topic review of literature
Ertz-Archambault, Natalie; Keim, Paul; Von Hoff, Daniel
2017-01-01
AIM To review microbiome alterations associated with pancreatic cancer, its potential utility in diagnostics, risk assessment, and influence on disease outcomes. METHODS A comprehensive literature review was conducted by all-inclusive topic review from PubMed, MEDLINE, and Web of Science. The last search was performed in October 2016. RESULTS Diverse microbiome alterations exist among several body sites including oral, gut, and pancreatic tissue, in patients with pancreatic cancer compared to healthy populations. CONCLUSION Pilot study successes in non-invasive screening strategies warrant further investigation for future translational application in early diagnostics and to learn modifiable risk factors relevant to disease prevention. Pre-clinical investigations exist in other tumor types that suggest microbiome manipulation provides opportunity to favorably transform cancer response to existing treatment protocols and improve survival. PMID:28348497
Zhang, Nan; Fan, Zhaoyang; Luo, Nan; Bi, Xiaoming; Zhao, Yike; An, Jing; Liu, Jiayi; Chen, Zhong; Fan, Zhanming; Li, Debiao
2016-02-01
To evaluate the feasibility and diagnostic performance of flow-sensitive dephasing (FSD)-prepared steady-state free precession (SSFP) MR angiography (MRA) for imaging infragenual arteries at 3.0T, with contrast enhanced MR angiography (CE MRA) as reference. Twenty consecutive patients with suspicion of lower extremity arterial disease undergoing routine CE MRA were recruited. FSD MRA was performed at calf before CE MRA. Image quality and stenosis degree of infragenual arteries from both techniques were independently evaluated and compared. Six patients in this study underwent DSA examination. Three undiagnostic segments were excluded with severe venous contamination in CE MRA. A total of 197 calf arterial segments images were analyzed. No significant difference existed in the relative signal intensity (rSI) of arterial segments between FSD MRA and CE MRA techniques (0.92 ± 0.09 versus 0.93 ± 0.05; P = 0.207). However, the subjective image quality score was slightly higher in FSD MRA (3.66 ± 0.81 versus 3.49 ± 0.87; P = 0.050). With CE MRA images as reference standard, slight overestimation existed in FSD MRA (2.19 ± 1.24 versus 2.09 ± 1.18; P = 0.019), with total agreement of 84.3% on the basis of all arterial segments. The sensitivity, specificity, negative predictive value, and positive predictive value of FSD MRA was 96.4%, 93.0%, 98.5%, and 84.1%. No significant difference in the stenosis degree score was detected between MRA (FSD MRA and CE MRA) and DSA (P > 0.05). FSD MRA performed on at 3.0T without the use of contrast medium provides diagnostic images allowing for arterial stenosis assessment of calf arteries that was highly comparable with CE MRA. Moreover, venous contamination was less problematic with FSD MRA. © 2015 Wiley Periodicals, Inc.
Matos, Olga; Lobo, Maria L; Gonçalves, Luzia; Antunes, Francisco
2002-01-01
The calcofluor stain (CF), the monoclonal antibody (MAb) 3B6 indirect immunofluorescence assay (IFA) and the modified trichrome blue stain (MT) were compared in terms of their reproducibility in a routine laboratory and in order to evaluate the percentage of cases of microsporidiosis in Portuguese HIV patients. A total of 166 faeces samples, 71 pulmonary specimens and 43 urine samples were studied using the 3 techniques. CF had a high sensitivity and a moderate specificity when applied to faeces samples. The sensitivity was lower with pulmonary specimens. The method is easy and quick to perform but readings take a long time to obtain. The MAb 3B6 IFA had a good to excellent sensitivity when applied to faeces and urine samples, but moderate sensitivity in pulmonary specimens. Readings were quick and easy to obtain, but the assay took longer to perform than the other 2 techniques. There was a greater correlation between the results obtained with the MT and MAb 3B6 IFA techniques than between those obtained with the MT and CF techniques. In conclusion, the MT performed better than the MAb 3B6 IFA and CF and continues to have an important place in a routine laboratory for the diagnosis of microsporidiosis. This work also confirms the existence of a relatively high proportion (30%) of cases of infection with Microsporidia, especially intestinal microsporidiosis, in HIV patients in Portugal.
Multiple Myeloma Minimal Residual Disease.
Paiva, Bruno; García-Sanz, Ramón; San Miguel, Jesús F
Assessment of minimal residual disease (MRD) is becoming standard diagnostic care for potentially curable neoplasms such as some acute leukemias as well as chronic myeloid and lymphocytic leukemia. Although multiple myeloma (MM) remains as an incurable disease, around half of the patients achieve complete remission (CR), and recent data suggests increasing rates of curability with "total-therapy-like" programs. This landscape is likely to be improved with the advent of new antibodies and small molecules. Therefore, conventional serological and morphological techniques have become suboptimal for sensitive evaluation of highly effective treatment strategies. Although, existing data suggests that MRD could be used as a biomarker to evaluate treatment efficacy, help on therapeutic decisions, and act as surrogate for overall survival, the role of MRD in MM is still a matter of extensive debate. Here, we review the different levels of remission used to define depth of response in MM and their clinical significance, as well as the prognostic value and unique characteristics of MRD detection using immunophenotypic, molecular, and imaging techniques. Key facts The higher efficacy of new treatment strategies for MM demand the incorporation of highly sensitive techniques to monitor treatment efficacy MRD could be used as a more potent surrogate biomarker for survival than standard CR We need to understand the pros and cons of the different MRD techniques The time has come to incorporate highly sensitive, cost-effective, readily available, and standardized MRD techniques into clinical trials to assess its role in therapeutic decisions.
Schulz, Alexandra; Daali, Samira; Javed, Mehreen; Fuchs, Paul Christian; Brockmann, Michael; Igressa, Alhadi; Charalampaki, Patra
2016-12-01
At present, no ideal diagnostic tools exist in the market to excise cancer tissue with the required safety margins and to achieve optimal aesthetic results using tissue-conserving techniques. In this prospective study, confocal laser endomicroscopy (CLE) and the traditional gold standard of magnifying glasses (MG) were compared regarding the boundaries of in vivo basal cell carcinoma and squamous cell carcinoma. Tumour diameters defined by both methods were measured and compared with those determined by histopathological examination. Nineteen patients were included in the study. The CLE technique was found to be superior to excisional margins based on MG only. Re-excision was required in 68% of the cases following excision based on MG evaluation, but only in 27% of the cases for whom excision margins were based on CLE. Our results are promising regarding the distinction between tumour and healthy surrounding tissue, and indicate that presurgical mapping of basal cell carcinoma and squamous cell carcinoma is possible. The tool itself should be developed further with special attention to early detection of skin cancer.
Tsirlin, Inna; Dupierrix, Eve; Chokron, Sylvie; Coquillart, Sabine; Ohlmann, Theophile
2009-04-01
Unilateral spatial neglect is a disabling condition frequently occurring after stroke. People with neglect suffer from various spatial deficits in several modalities, which in many cases impair everyday functioning. A successful treatment is yet to be found. Several techniques have been proposed in the last decades, but only a few showed long-lasting effects and none could completely rehabilitate the condition. Diagnostic methods of neglect could be improved as well. The disorder is normally diagnosed with pen-and-paper methods, which generally do not assess patients in everyday tasks and do not address some forms of the disorder. Recently, promising new methods based on virtual reality have emerged. Virtual reality technologies hold great opportunities for the development of effective assessment and treatment techniques for neglect because they provide rich, multimodal, and highly controllable environments. In order to stimulate advancements in this domain, we present a review and an analysis of the current work. We describe past and ongoing research of virtual reality applications for unilateral neglect and discuss the existing problems and new directions for development.
Prediction and near-field observation of skull-guided acoustic waves
NASA Astrophysics Data System (ADS)
Estrada, Héctor; Rebling, Johannes; Razansky, Daniel
2017-06-01
Ultrasound waves propagating in water or soft biological tissue are strongly reflected when encountering the skull, which limits the use of ultrasound-based techniques in transcranial imaging and therapeutic applications. Current knowledge on the acoustic properties of the cranial bone is restricted to far-field observations, leaving its near-field unexplored. We report on the existence of skull-guided acoustic waves, which was herein confirmed by near-field measurements of optoacoustically-induced responses in ex-vivo murine skulls immersed in water. Dispersion of the guided waves was found to reasonably agree with the prediction of a multilayered flat plate model. We observed a skull-guided wave propagation over a lateral distance of at least 3 mm, with a half-decay length in the direction perpendicular to the skull ranging from 35 to 300 μm at 6 and 0.5 MHz, respectively. Propagation losses are mostly attributed to the heterogenous acoustic properties of the skull. It is generally anticipated that our findings may facilitate and broaden the application of ultrasound-mediated techniques in brain diagnostics and therapy.
Prediction and near-field observation of skull-guided acoustic waves.
Estrada, Héctor; Rebling, Johannes; Razansky, Daniel
2017-06-21
Ultrasound waves propagating in water or soft biological tissue are strongly reflected when encountering the skull, which limits the use of ultrasound-based techniques in transcranial imaging and therapeutic applications. Current knowledge on the acoustic properties of the cranial bone is restricted to far-field observations, leaving its near-field unexplored. We report on the existence of skull-guided acoustic waves, which was herein confirmed by near-field measurements of optoacoustically-induced responses in ex-vivo murine skulls immersed in water. Dispersion of the guided waves was found to reasonably agree with the prediction of a multilayered flat plate model. We observed a skull-guided wave propagation over a lateral distance of at least 3 mm, with a half-decay length in the direction perpendicular to the skull ranging from 35 to 300 μm at 6 and 0.5 MHz, respectively. Propagation losses are mostly attributed to the heterogenous acoustic properties of the skull. It is generally anticipated that our findings may facilitate and broaden the application of ultrasound-mediated techniques in brain diagnostics and therapy.
Large-scale retrieval for medical image analytics: A comprehensive review.
Li, Zhongyu; Zhang, Xiaofan; Müller, Henning; Zhang, Shaoting
2018-01-01
Over the past decades, medical image analytics was greatly facilitated by the explosion of digital imaging techniques, where huge amounts of medical images were produced with ever-increasing quality and diversity. However, conventional methods for analyzing medical images have achieved limited success, as they are not capable to tackle the huge amount of image data. In this paper, we review state-of-the-art approaches for large-scale medical image analysis, which are mainly based on recent advances in computer vision, machine learning and information retrieval. Specifically, we first present the general pipeline of large-scale retrieval, summarize the challenges/opportunities of medical image analytics on a large-scale. Then, we provide a comprehensive review of algorithms and techniques relevant to major processes in the pipeline, including feature representation, feature indexing, searching, etc. On the basis of existing work, we introduce the evaluation protocols and multiple applications of large-scale medical image retrieval, with a variety of exploratory and diagnostic scenarios. Finally, we discuss future directions of large-scale retrieval, which can further improve the performance of medical image analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Committee Opinion No. 723 Summary: Guidelines for Diagnostic Imaging During Pregnancy and Lactation.
2017-10-01
Imaging studies are important adjuncts in the diagnostic evaluation of acute and chronic conditions. However, confusion about the safety of these modalities for pregnant and lactating women and their infants often results in unnecessary avoidance of useful diagnostic tests or the unnecessary interruption of breastfeeding. Ultrasonography and magnetic resonance imaging are not associated with risk and are the imaging techniques of choice for the pregnant patient, but they should be used prudently and only when use is expected to answer a relevant clinical question or otherwise provide medical benefit to the patient. With few exceptions, radiation exposure through radiography, computed tomography scan, or nuclear medicine imaging techniques is at a dose much lower than the exposure associated with fetal harm. If these techniques are necessary in addition to ultrasonography or magnetic resonance imaging or are more readily available for the diagnosis in question, they should not be withheld from a pregnant patient. Breastfeeding should not be interrupted after gadolinium administration.
Committee Opinion No. 723: Guidelines for Diagnostic Imaging During Pregnancy and Lactation.
2017-10-01
Imaging studies are important adjuncts in the diagnostic evaluation of acute and chronic conditions. However, confusion about the safety of these modalities for pregnant and lactating women and their infants often results in unnecessary avoidance of useful diagnostic tests or the unnecessary interruption of breastfeeding. Ultrasonography and magnetic resonance imaging are not associated with risk and are the imaging techniques of choice for the pregnant patient, but they should be used prudently and only when use is expected to answer a relevant clinical question or otherwise provide medical benefit to the patient. With few exceptions, radiation exposure through radiography, computed tomography scan, or nuclear medicine imaging techniques is at a dose much lower than the exposure associated with fetal harm. If these techniques are necessary in addition to ultrasonography or magnetic resonance imaging or are more readily available for the diagnosis in question, they should not be withheld from a pregnant patient. Breastfeeding should not be interrupted after gadolinium administration.
Dworkin, Robert H; Bruehl, Stephen; Fillingim, Roger B; Loeser, John D; Terman, Gregory W; Turk, Dennis C
2016-09-01
A variety of approaches have been used to develop diagnostic criteria for chronic pain. The published evidence of the reliability and validity of existing diagnostic criteria is limited, and these criteria have typically not been used in clinical practice. The availability of a widely accepted, consistently applied, and evidence-based taxonomy of diagnostic criteria would improve the quality of clinical research on chronic pain and would be of great value in clinical practice. To address the need for evidence-based diagnostic criteria for the major chronic pain conditions, the Analgesic, Anesthetic, and Addiction Clinical Trial Translations, Innovations, Opportunities, and Networks (ACTTION) public-private partnership with the US Food and Drug Administration and the American Pain Society (APS) have collaborated on the development of the ACTTION-APS Pain Taxonomy (AAPT). AAPT provides a multidimensional framework that is applied systematically in the development of diagnostic criteria. This article (1) describes the background and rationale for AAPT; (2) presents the AAPT taxonomy and the specific conditions for which diagnostic criteria have been developed (to be published separately); (3) briefly reviews the 5 dimensions that constitute the AAPT multidimensional framework and describes the 7 accompanying articles that discuss these dimensions and other important issues involving AAPT; and (4) provides an overview of next steps, specifically, the general processes by which the initial set of diagnostic criteria (for which the evidence base has been drawn from the literature, systematic reviews, and secondary analyses of existing databases) will undergo additional assessments of reliability and validity. To address the need for evidence-based diagnostic criteria for the major chronic pain conditions, the AAPT provides a multidimensional framework that is applied systematically in the development of diagnostic criteria. The long-term objective of AAPT is to advance the scientific understanding of chronic pain and its treatment. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.
Schaafsma, Joanna D; van der Graaf, Yolanda; Rinkel, Gabriel J E; Buskens, Erik
2009-12-01
The lack of a standard methodology in diagnostic research impedes adequate evaluation before implementation of constantly developing diagnostic techniques. We discuss the methodology of diagnostic research and underscore the relevance of decision analysis in the process of evaluation of diagnostic tests. Overview and conceptual discussion. Diagnostic research requires a stepwise approach comprising assessment of test characteristics followed by evaluation of added value, clinical outcome, and cost-effectiveness. These multiple goals are generally incompatible with a randomized design. Decision-analytic models provide an important alternative through integration of the best available evidence. Thus, critical assessment of clinical value and efficient use of resources can be achieved. Decision-analytic models should be considered part of the standard methodology in diagnostic research. They can serve as a valid alternative to diagnostic randomized clinical trials (RCTs).
ERIC Educational Resources Information Center
Rao, Patricia A.; Landa, Rebecca J.
2014-01-01
Autism spectrum disorder and attention deficit hyperactivity disorder are neurodevelopmental disorders that cannot be codiagnosed under existing diagnostic guidelines ("Diagnostic and Statistical Manual of the American Psychiatric Association," 4th ed., text rev.). However, reports are emerging that attention deficit hyperactivity…
Research Support for the Instructional Strategy Diagnostic Profile. Technical Report No. 3
ERIC Educational Resources Information Center
Merrill, M. David; And Others
By using a taxonomy of instructional strategy variables, an Instructional Strategy Diagnostic Profile (ISDP) was developed which can be used either to determine a judged index of instructional effectiveness for a previously designed instructional product or to guide the design and development of a new instructional product. Existing experimental…
Radiofrequency recombination lines as diagnostics of the cool interstellar medium.
NASA Technical Reports Server (NTRS)
Dupree, A. K.
1971-01-01
Quantitative details are given of a new diagnostic technique for the carbon and hydrogen (H I) recombination lines. Theoretical results are presented for conditions expected in H I clouds, and are compared with available observations for Orion A and NGC 2024.
NASA Astrophysics Data System (ADS)
Abd-el-Malek, Mina; Abdelsalam, Ahmed K.; Hassan, Ola E.
2017-09-01
Robustness, low running cost and reduced maintenance lead Induction Motors (IMs) to pioneerly penetrate the industrial drive system fields. Broken rotor bars (BRBs) can be considered as an important fault that needs to be early assessed to minimize the maintenance cost and labor time. The majority of recent BRBs' fault diagnostic techniques focus on differentiating between healthy and faulty rotor cage. In this paper, a new technique is proposed for detecting the location of the broken bar in the rotor. The proposed technique relies on monitoring certain statistical parameters estimated from the analysis of the start-up stator current envelope. The envelope of the signal is obtained using Hilbert Transformation (HT). The proposed technique offers non-invasive, fast computational and accurate location diagnostic process. Various simulation scenarios are presented that validate the effectiveness of the proposed technique.
Sandmeier, Franziska C; Weitzman, Chava L; Maloney, K Nichole; Tracy, C Richard; Nieto, Nathan; Teglas, Mike B; Hunter, Kenneth W; DuPré, Sally; Gienger, C M; Tuma, Michael W
2017-01-01
Pathogens that cause subclinical diseases or exhibit low infection intensities are difficult to quantify in wild populations. Mojave desert tortoises ( Gopherus agassizii ) have been the focus of much research aimed at measuring the presence of upper respiratory disease (URTD) and URTD-associated pathogens, and techniques used to quantify disease in Gopherus species have also been used for disease surveillance in other species of turtles and tortoises of conservation concern. Published surveys of G. agassizii populations have found a relatively low prevalence of URTD, with most URTD-positive animals exhibiting moderate, intermittent signs of morbidity. Therefore, multiple tests have been developed to quantify URTD including genetic detection of the pathogens Mycoplasma agassizii and Mycoplasma testudineum , detection of M. agassizii -specific antibodies, and standardized quantification of clinical signs of URTD and body condition. These diagnostic tests have only been compared in diseased or moribund, semicaptive animals. We compared diagnostic techniques (TaqMan® and SYBR™ Green qPCR, serology, and visible examination) to detect M. agassizii -associated URTD in 126 wild desert tortoises sampled in Nevada and California, US in 2010. All had healthy body condition indices and none exhibited more than mild-to-moderate visual signs of URTD. Pairwise comparisons of diagnostic techniques indicated poor performance in diagnosing disease in individual animals. We found stronger, but inconsistent, statistical associations among diagnostic techniques at the population level. Our findings have implications for quantifying subclinical respiratory disease in tortoises.
Doctoral theses in diagnostic imaging: a study of Spanish production between 1976 and 2011.
Machan, K; Sendra Portero, F
2018-05-15
To analyze the production of doctoral theses in diagnostic imaging in Spain in the period comprising 1976 through 2011 with the aim of a) determining the number of theses and their distribution over time, b) describing the production in terms of universities and directors, and c) analyzing the content of the theses according to the imaging technique, anatomic site, and type of research used. The TESEO database was searched for "radiología" and/or "diagnóstico por imagen" and for terms related to diagnostic imaging in the title of the thesis. A total of 1036 theses related to diagnostic imaging were produced in 37 Spanish universities (mean, 29.6 theses/year; range, 4-59). A total of 963 thesis directors were identified; 10 of these supervised 10 or more theses. Most candidates and directors were men, although since the 2000-2001 academic year the number of male and female candidates has been similar. The anatomic regions most often included in diagnostic imaging theses were the abdomen (22.5%), musculoskeletal system (21.8%), central nervous system (16.4%), and neck and face (15.6%). The imaging techniques most often included were ultrasonography in the entire period (25.5%) and magnetic resonance imaging in the last 5 years. Most theses (63.8%) were related to clinical research. Despite certain limitations, the TESEO database makes it possible to analyze the production of doctoral theses in Spain effectively. The annual mean production of theses in diagnostic imaging is higher than in other medical specialties. This analysis reflects the historic evolution of imaging techniques and research in radiology as well as the development of Spanish universities. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Develop Advanced Nonlinear Signal Analysis Topographical Mapping System
NASA Technical Reports Server (NTRS)
Jong, Jen-Yi
1997-01-01
During the development of the SSME, a hierarchy of advanced signal analysis techniques for mechanical signature analysis has been developed by NASA and AI Signal Research Inc. (ASRI) to improve the safety and reliability for Space Shuttle operations. These techniques can process and identify intelligent information hidden in a measured signal which is often unidentifiable using conventional signal analysis methods. Currently, due to the highly interactive processing requirements and the volume of dynamic data involved, detailed diagnostic analysis is being performed manually which requires immense man-hours with extensive human interface. To overcome this manual process, NASA implemented this program to develop an Advanced nonlinear signal Analysis Topographical Mapping System (ATMS) to provide automatic/unsupervised engine diagnostic capabilities. The ATMS will utilize a rule-based Clips expert system to supervise a hierarchy of diagnostic signature analysis techniques in the Advanced Signal Analysis Library (ASAL). ASAL will perform automatic signal processing, archiving, and anomaly detection/identification tasks in order to provide an intelligent and fully automated engine diagnostic capability. The ATMS has been successfully developed under this contract. In summary, the program objectives to design, develop, test and conduct performance evaluation for an automated engine diagnostic system have been successfully achieved. Software implementation of the entire ATMS system on MSFC's OISPS computer has been completed. The significance of the ATMS developed under this program is attributed to the fully automated coherence analysis capability for anomaly detection and identification which can greatly enhance the power and reliability of engine diagnostic evaluation. The results have demonstrated that ATMS can significantly save time and man-hours in performing engine test/flight data analysis and performance evaluation of large volumes of dynamic test data.
Pablant, N A; Burrell, K H; Groebner, R J; Holcomb, C T; Kaplan, D H
2010-10-01
Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D(α) emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B(θ)/B(T) and ∣B∣ over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0×10(19) m(-3), and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.
McCarthy, James S.; Lustigman, Sara; Yang, Guo-Jing; Barakat, Rashida M.; García, Héctor H.; Sripa, Banchob; Willingham, Arve Lee; Prichard, Roger K.; Basáñez, María-Gloria
2012-01-01
Diagnostic tools appropriate for undertaking interventions to control helminth infections are key to their success. Many diagnostic tests for helminth infection have unsatisfactory performance characteristics and are not well suited for use in the parasite control programmes that are being increasingly implemented. Although the application of modern laboratory research techniques to improve diagnostics for helminth infection has resulted in some technical advances, uptake has not been uniform. Frequently, pilot or proof of concept studies of promising diagnostic technologies have not been followed by much needed product development, and in many settings diagnosis continues to rely on insensitive and unsatisfactory parasitological or serodiagnostic techniques. In contrast, PCR-based xenomonitoring of arthropod vectors, and use of parasite recombinant proteins as reagents for serodiagnostic tests, have resulted in critical advances in the control of specific helminth parasites. The Disease Reference Group on Helminths Infections (DRG4), established in 2009 by the Special Programme for Research and Training in Tropical Diseases (TDR) was given the mandate to review helminthiases research and identify research priorities and gaps. In this review, the diagnostic technologies relevant to control of helminth infections, either available or in development, are reviewed. Critical gaps are identified and opportunities to improve needed technologies are discussed. PMID:22545166
NASA Technical Reports Server (NTRS)
Glover, R. C.; Kelley, B. A.; Tischer, A. E.
1986-01-01
The results of a review of the Space Shuttle Main Engine (SSME) failure data for the period 1980 through 1983 are presented. The data was collected, evaluated, and ranked according to procedures established during this study. A number of conclusions and recommendations are made based upon this failure data review. The results of a state-of-the-art diagnostic survey are also presented. This survey covered a broad range of diagnostic sensors and techniques and the findings were evaluated for application to the SSME. Finally, a discussion of the initial activities for the on-going SSME diagnostic evaluation is included.
The Difficulty of Selecting the NANDA-I Nursing Diagnosis (2015-2017) of "Death Anxiety" in Japan.
Shimomai, Kimiyo; Furukawa, Hidetoshi; Kuroda, Yuko; Fukuda, Kazuaki; Masuda, Mitsumi; Koizumi, Junko
2018-01-01
The purpose of our study was to clarify any difficulties or problems that exist in Japanese healthcare sites regarding the selection of death anxiety as a nursing diagnosis. This study was a qualitative, inductive research design. The semistructured interviews were conducted on the participants who were nurses and had 3 or more years of clinical experience in Japan. Results showed four categories: "The Japanese have a culture of avoiding death," "It is extremely difficult to match diagnostic indicators and related factors with specific patient cases," "Other diagnoses exist that are effective and enable proactive intervention," and "The definition of death anxiety and the meaning of its diagnostic indicators are unintelligible." It is thought that nursing diagnoses that reflect specific cultural backgrounds require definitions appropriate to each country and appropriate revisions to diagnostic indicators. © 2016 NANDA International, Inc.
Ultrasonic imaging: safety considerations
ter Haar, Gail
2011-01-01
Modern ultrasound imaging for diagnostic purposes has a wide range of applications. It is used in obstetrics to monitor the progress of pregnancy, in oncology to visualize tumours and their response to treatment, and, in cardiology, contrast-enhanced studies are used to investigate heart function and physiology. An increasing use of diagnostic ultrasound is to provide the first photograph for baby's album—in the form of a souvenir or keepsake scan that might be taken as part of a routine investigation, or during a visit to an independent high-street ‘boutique’. It is therefore important to ensure that any benefit accrued from these applications outweighs any accompanying risk, and to evaluate the existing ultrasound bio-effect and epidemiology literature with this in mind. This review considers the existing laboratory and epidemiological evidence about the safety of diagnostic ultrasound and puts it in the context of current clinical usage. PMID:22866238
Canon, Abbey J; Lauterbach, Nicholas; Bates, Jessica; Skoland, Kristin; Thomas, Paul; Ellingson, Josh; Ruston, Chelsea; Breuer, Mary; Gerardy, Kimberlee; Hershberger, Nicole; Hayman, Kristen; Buckley, Alexis; Holtkamp, Derald; Karriker, Locke
2017-06-15
OBJECTIVE To develop and evaluate a pyramid training method for teaching techniques for collection of diagnostic samples from swine. DESIGN Experimental trial. SAMPLE 45 veterinary students. PROCEDURES Participants went through a preinstruction assessment to determine their familiarity with the equipment needed and techniques used to collect samples of blood, nasal secretions, feces, and oral fluid from pigs. Participants were then shown a series of videos illustrating the correct equipment and techniques for collecting samples and were provided hands-on pyramid-based instruction wherein a single swine veterinarian trained 2 or 3 participants on each of the techniques and each of those participants, in turn, trained additional participants. Additional assessments were performed after the instruction was completed. RESULTS Following the instruction phase, percentages of participants able to collect adequate samples of blood, nasal secretions, feces, and oral fluid increased, as did scores on a written quiz assessing participants' ability to identify the correct equipment, positioning, and procedures for collection of samples. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the pyramid training method may be a feasible way to rapidly increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.
A diagnostic analysis of the VVP single-doppler retrieval technique
NASA Technical Reports Server (NTRS)
Boccippio, Dennis J.
1995-01-01
A diagnostic analysis of the VVP (volume velocity processing) retrieval method is presented, with emphasis on understanding the technique as a linear, multivariate regression. Similarities and differences to the velocity-azimuth display and extended velocity-azimuth display retrieval techniques are discussed, using this framework. Conventional regression diagnostics are then employed to quantitatively determine situations in which the VVP technique is likely to fail. An algorithm for preparation and analysis of a robust VVP retrieval is developed and applied to synthetic and actual datasets with high temporal and spatial resolution. A fundamental (but quantifiable) limitation to some forms of VVP analysis is inadequate sampling dispersion in the n space of the multivariate regression, manifest as a collinearity between the basis functions of some fitted parameters. Such collinearity may be present either in the definition of these basis functions or in their realization in a given sampling configuration. This nonorthogonality may cause numerical instability, variance inflation (decrease in robustness), and increased sensitivity to bias from neglected wind components. It is shown that these effects prevent the application of VVP to small azimuthal sectors of data. The behavior of the VVP regression is further diagnosed over a wide range of sampling constraints, and reasonable sector limits are established.
Making a structured psychiatric diagnostic interview faithful to the nomenclature.
Robins, Lee N; Cottler, Linda B
2004-10-15
Psychiatric diagnostic interviews to be used in epidemiologic studies by lay interviewers have, since the 1970s, attempted to operationalize existing psychiatric nomenclatures. How to maximize the chances that they do so successfully has not previously been spelled out. In this article, the authors discuss strategies for each of the seven steps involved in writing, updating, or modifying a diagnostic interview and its supporting materials: 1) writing questions that match the nomenclature's criteria, 2) checking that respondents will be willing and able to answer the questions, 3) choosing a format acceptable to interviewers that maximizes accurate answering and recording of answers, 4) constructing a data entry and cleaning program that highlights errors to be corrected, 5) creating a diagnostic scoring program that matches the nomenclature's algorithms, 6) developing an interviewer training program that maximizes reliability, and 7) computerizing the interview. For each step, the authors discuss how to identify errors, correct them, and validate the revisions. Although operationalization will never be perfect because of ambiguities in the nomenclature, specifying methods for minimizing divergence from the nomenclature is timely as users modify existing interviews and look forward to updating interviews based on the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition, and the International Classification of Diseases, Eleventh Revision.
Rayleigh Scattering Diagnostic for Simultaneous Measurements of Dynamic Density and Velocity
NASA Technical Reports Server (NTRS)
Seasholtz, Richard G.; Panda, J.
2000-01-01
A flow diagnostic technique based on the molecular Rayleigh scattering of laser light is used to obtain dynamic density and velocity data in turbulent flows. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer and recording information about the interference pattern with a multiple anode photomultiplier tube (PMT). An artificial neural network is used to process the signals from the PMT to recover the velocity time history, which is then used to calculate the velocity power spectrum. The technique is illustrated using simulated data. The results of an experiment to measure the velocity power spectrum in a low speed (100 rn/sec) flow are also presented.
A Review of Recent Developments in X-Ray Diagnostics for Turbulent and Optically Dense Rocket Sprays
NASA Technical Reports Server (NTRS)
Radke, Christopher; Halls, Benjamin; Kastengren, Alan; Meyer, Terrence
2017-01-01
Highly efficient mixing and atomization of fuel and oxidizers is an important factor in many propulsion and power generating applications. To better quantify breakup and mixing in atomizing sprays, several diagnostic techniques have been developed to collect droplet information and spray statistics. Several optical based techniques, such as Ballistic Imaging and SLIPI have previously demonstrated qualitative measurements in optically dense sprays, however these techniques have produced limited quantitative information in the near injector region. To complement to these advances, a recent wave of developments utilizing synchrotron based x-rays have been successful been implemented facilitating the collection of quantitative measurements in optically dense sprays.
Sporotrichosis: From KOH to Molecular Biology.
Arenas, Roberto; Sánchez-Cardenas, Carlos D; Ramirez-Hobak, Lourdes; Ruíz Arriaga, Leon Felipe; Vega Memije, Ma Elisa
2018-05-23
Sporotrichosis is a cosmopolitan, chronic granulomatous mycosis, acquired by traumatic inoculation and caused by Sporothrix schenckii complex . Several methods of diagnostic are available, from KOH to molecular biology. In this review, we describe from the simplest (clinical diagnosis) to the most advanced diagnostic techniques (molecular biology).
The future of medical diagnostics: review paper
2011-01-01
While histopathology of excised tissue remains the gold standard for diagnosis, several new, non-invasive diagnostic techniques are being developed. They rely on physical and biochemical changes that precede and mirror malignant change within tissue. The basic principle involves simple optical techniques of tissue interrogation. Their accuracy, expressed as sensitivity and specificity, are reported in a number of studies suggests that they have a potential for cost effective, real-time, in situ diagnosis. We review the Third Scientific Meeting of the Head and Neck Optical Diagnostics Society held in Congress Innsbruck, Innsbruck, Austria on the 11th May 2011. For the first time the HNODS Annual Scientific Meeting was held in association with the International Photodynamic Association (IPA) and the European Platform for Photodynamic Medicine (EPPM). The aim was to enhance the interdisciplinary aspects of optical diagnostics and other photodynamic applications. The meeting included 2 sections: oral communication sessions running in parallel to the IPA programme and poster presentation sessions combined with the IPA and EPPM posters sessions. PMID:21861912
[Molecular diagnostics of ALK-positive lung cancer].
Tímár, József; Lotz, Gábor; Rásó, Erzsébet; Moldvay, Judit
2017-09-20
ALK translocation is the 3rd most frequent genetic aberration in lung adenocarcinoma, and several inhibitors are now clinically available in first and second line settings. Accordingly, molecular diagnostics of ALK-positive lung cancer is very important and can be done with the rational combination of several methods. All international recommendations suggest that, except for cytological samples, screening technology for ALK-positive tumors is immunohistochemistry using a validated test. It is highly recommended that in case of ALK protein positive samples gene translocation must be confirmed by fluorescent in situ hybridization (FISH). In case of cytological samples FISH technique must be used as ALK diagnostics. In equivocal cases the genetic alteration of ALK can be confirmed by alternative molecular techniques such as next generation sequencing or RNAbased PCR methods. Upon administration of ALK inhibitors, acquired resistance is frequent which is mostly due to ALK amplification and/or mutation. It is evident that the diagnostics of these secondary ALK gene alterations must be done from recurrent tumors or circulating nucleic acids.
Fluorescence analysis of ubiquinone and its application in quality control of medical supplies
NASA Astrophysics Data System (ADS)
Timofeeva, Elvira O.; Gorbunova, Elena V.; Chertov, Aleksandr N.
2017-02-01
The presence of antioxidant issues such as redox potential imbalance in human body is a very important question for modern clinical diagnostics. Implementation of fluorescence analysis into optical diagnostics of such wide distributed in a human body antioxidant as ubiquinone is one of the steps for development of the device with a view to clinical diagnostics of redox potential. Recording of fluorescence was carried out with spectrometer using UV irradiation source with thin band (max at 287 and 330 nm) as a background radiation. Concentrations of ubiquinone from 0.25 to 2.5 mmol/l in explored samples were used for investigation. Recording data was processed using correlation analysis and differential analytical technique. The fourth derivative spectrum of fluorescence spectrum provided the basis for a multicomponent analysis of the solutions. As a technique in clinical diagnostics fluorescence analysis with processing method including differential spectrophotometry, it is step forward towards redox potential calculation and quality control in pharmacy for better health care.
Kriegsmann, Jörg; Kriegsmann, Mark; Casadonte, Rita
2015-03-01
Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) imaging mass spectrometry (IMS) is an evolving technique in cancer diagnostics and combines the advantages of mass spectrometry (proteomics), detection of numerous molecules, and spatial resolution in histological tissue sections and cytological preparations. This method allows the detection of proteins, peptides, lipids, carbohydrates or glycoconjugates and small molecules.Formalin-fixed paraffin-embedded tissue can also be investigated by IMS, thus, this method seems to be an ideal tool for cancer diagnostics and biomarker discovery. It may add information to the identification of tumor margins and tumor heterogeneity. The technique allows tumor typing, especially identification of the tumor of origin in metastatic tissue, as well as grading and may provide prognostic information. IMS is a valuable method for the identification of biomarkers and can complement histology, immunohistology and molecular pathology in various fields of histopathological diagnostics, especially with regard to identification and grading of tumors.
Strategy and optimization of diagnostic imaging in painful hip in adults.
Blum, A; Raymond, A; Teixeira, P
2015-02-01
Diagnostic imaging strategy in painful hip depends on many factors, but in all cases, plain X-ray is the first investigation. It may be sufficient to reach diagnosis and determine treatment options. More effective but more expensive exploration is indicated in two circumstances: when plain X-ray is non-contributive, and when diagnosis has been established but more accurate imaging assessment is needed to guide treatment. Following radiography, the choice of imaging techniques depends not only on the suspected pathology but also on the availability of equipment and its performance. MRI is probably the technique that provides the most comprehensive results; recent improved accessibility has significantly simplified the diagnostic algorithm. CT remains invaluable, and current techniques have reduced patient irradiation to a level similar to that of standard X-ray. Finally, cost is an important consideration in choosing the means of exploration, but the overall financial impact of the various strategies for diagnosis of painful hip is not well established. This article aims to provide a simple and effective diagnostic strategy for the assessment of painful hip, taking account of the clinical situation, and to detail the most typical semiologic patterns of each disease affecting this joint. Copyright © 2015. Published by Elsevier Masson SAS.
Non-invasive diagnostics of the maxillary and frontal sinuses based on diode laser gas spectroscopy.
Lewander, Märta; Lindberg, Sven; Svensson, Tomas; Siemund, Roger; Svanberg, Katarina; Svanberg, Sune
2012-03-01
Suspected, but objectively absent, rhinosinusitis constitutes a major cause of visits to the doctor, high health care costs, and the over-prescription of antibiotics, contributing to the serious problem of resistant bacteria. This situation is largely due to a lack of reliable and widely applicable diagnostic methods. A novel method for the diagnosis of rhinosinusitis based on non-intrusive diode laser gas spectroscopy is presented. The technique is based on light absorption by free gas (oxygen and water vapour) inside the sinuses, and has the potential to be a complementary diagnostic tool in primary health care. The method was evaluated on 40 patients with suspected sinus problems, referred to the diagnostic radiology clinic for low-dose computed tomography (CT), which was used as the reference technique. The data obtained with the new laser-based method correlated well with the grading of opacification and ventilation using CT. The sensitivity and specificity were estimated to be 93% and 61%, respectively, for the maxillary sinuses, and 94% and 86%, respectively, for the frontal sinuses. Good reproducibility was shown. The laser-based technique presents real-time clinical data that correlate well to CT findings, while being non-intrusive and avoiding the use of ionizing radiation.
Signal Detection Techniques for Diagnostic Monitoring of Space Shuttle Main Engine Turbomachinery
NASA Technical Reports Server (NTRS)
Coffin, Thomas; Jong, Jen-Yi
1986-01-01
An investigation to develop, implement, and evaluate signal analysis techniques for the detection and classification of incipient mechanical failures in turbomachinery is reviewed. A brief description of the Space Shuttle Main Engine (SSME) test/measurement program is presented. Signal analysis techniques available to describe dynamic measurement characteristics are reviewed. Time domain and spectral methods are described, and statistical classification in terms of moments is discussed. Several of these waveform analysis techniques have been implemented on a computer and applied to dynamc signals. A laboratory evaluation of the methods with respect to signal detection capability is described. A unique coherence function (the hyper-coherence) was developed through the course of this investigation, which appears promising as a diagnostic tool. This technique and several other non-linear methods of signal analysis are presented and illustrated by application. Software for application of these techniques has been installed on the signal processing system at the NASA/MSFC Systems Dynamics Laboratory.
Visualization techniques for tongue analysis in traditional Chinese medicine
NASA Astrophysics Data System (ADS)
Pham, Binh L.; Cai, Yang
2004-05-01
Visual inspection of the tongue has been an important diagnostic method of Traditional Chinese Medicine (TCM). Clinic data have shown significant connections between various viscera cancers and abnormalities in the tongue and the tongue coating. Visual inspection of the tongue is simple and inexpensive, but the current practice in TCM is mainly experience-based and the quality of the visual inspection varies between individuals. The computerized inspection method provides quantitative models to evaluate color, texture and surface features on the tongue. In this paper, we investigate visualization techniques and processes to allow interactive data analysis with the aim to merge computerized measurements with human expert's diagnostic variables based on five-scale diagnostic conditions: Healthy (H), History Cancers (HC), History of Polyps (HP), Polyps (P) and Colon Cancer (C).
[Spiral CT angiography in practice].
Pavcec, Zlatko; Zokalj, Ivan; Rumboldt, Zoran; Pal, Andrej; Saghir, Hussein; Ozretić, David; Latin, Branko; Perhoć, Zeljka; Marotti, Miljenko
2005-01-01
Incidence of vascular diseases and development of new radiologic techniques in the last three decades has given strong impuls for introduction of non-invasive vascular diagnostic methods. Thanks to the introduction of Doppler ultrasound, new types of computed tomography (CT) and magnetic resonance (MR) scanners, non-invasive vascular diagnostic methods are replacing conventional invasive (catheter) angiographic methods. Computed tomographic angiography (CTA) is a noninvasive vascular diagnostic method based on continuous scanning with CT scanner during intravenous application of contrast material. Performing of CTA is possible after introduction of spiral CT technique whose characteristics are short imaging time and volumetric data acquisition. The main goal of this article, based on our experiences, is to review the role of CTA, performed on single-slice CT scanner, in managment of patients with vascular pathology.
The LeRC rail accelerators: Test designs and diagnostic techniques
NASA Technical Reports Server (NTRS)
Zana, L. M.; Kerslake, W. R.; Sturman, J. C.; Wang, S. Y.; Terdan, F. F.
1983-01-01
The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed.
Field-friendly techniques for assessment of biomarkers of nutrition for development1234
Garrett, Dean A; Sangha, Jasbir K; Kothari, Monica T; Boyle, David
2011-01-01
Whereas cost-effective interventions exist for the control of micronutrient malnutrition (MN), in low-resource settings field-friendly tools to assess the effect of these interventions are underutilized or not readily available where they are most needed. Conventional approaches for MN measurement are expensive and require relatively sophisticated laboratory instrumentation, skilled technicians, good infrastructure, and reliable sources of clean water and electricity. Consequently, there is a need to develop and introduce innovative tools that are appropriate for MN assessment in low-resource settings. These diagnostics should be cost-effective, simple to perform, robust, accurate, and capable of being performed with basic laboratory equipment. Currently, such technologies either do not exist or have been applied to the assessment of a few micronutrients. In the Demographic and Health Surveys (DHS), a few such examples for which “biomarkers” of nutrition development have been assessed in low-resource settings using field-friendly approaches are hemoglobin (anemia), retinol-binding protein (vitamin A), and iron (transferrin receptor). In all of these examples, samples were collected mainly by nonmedical staff and analyses were conducted in the survey country by technicians from the local health or research facilities. This article provides information on how the DHS has been able to successfully adapt field-friendly techniques in challenging environments in population-based surveys for the assessment of micronutrient deficiencies. Special emphasis is placed on sample collection, processing, and testing in relation to the availability of local technology, resources, and capacity. PMID:21677055
Fusion alpha-particle diagnostics for DT experiments on the joint European torus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiptily, V. G.; Beaumont, P.; Syme, D. B.
2014-08-21
JET equipped with ITER-like wall (a beryllium wall and a tungsten divertor) can provide auxiliary heating with power up to 35MW, producing a significant population of α-particles in DT operation. The direct measurements of alphas are very difficult and α-particle studies require a significant development of dedicated diagnostics. JET now has an excellent set of confined and lost fast particle diagnostics for measuring the α-particle source and its evolution in space and time, α-particle energy distribution, and α-particle losses. This paper describes how the above mentioned JET diagnostic systems could be used for α-particle measurements, and what options exist formore » keeping the essential α-particle diagnostics functioning well in the presence of intense DT neutron flux. Also, α-particle diagnostics for ITER are discussed.« less
Small business development for molecular diagnostics.
Anagostou, Anthanasia; Liotta, Lance A
2012-01-01
Molecular profiling, which is the application of molecular diagnostics technology to tissue and blood -specimens, is an integral element in the new era of molecular medicine and individualized therapy. Molecular diagnostics is a fertile ground for small business development because it can generate products that meet immediate demands in the health-care sector: (a) Detection of disease risk, or early-stage disease, with a higher specificity and sensitivity compared to previous testing methods, and (b) "Companion diagnostics" for stratifying patients to receive a treatment choice optimized to their individual disease. This chapter reviews the promise and challenges of business development in this field. Guidelines are provided for the creation of a business model and the generation of a marketing plan around a candidate molecular diagnostic product. Steps to commercialization are outlined using existing molecular diagnostics companies as learning examples.
Tsalik, Ephraim L; Petzold, Elizabeth; Kreiswirth, Barry N; Bonomo, Robert A; Banerjee, Ritu; Lautenbach, Ebbing; Evans, Scott R; Hanson, Kimberly E; Klausner, Jeffrey D; Patel, Robin
2017-03-15
Diagnostics are a cornerstone of the practice of infectious diseases. However, various limitations frequently lead to unmet clinical needs. In most other domains, diagnostics focus on narrowly defined questions, provide readily interpretable answers, and use true gold standards for development. In contrast, infectious diseases diagnostics must contend with scores of potential pathogens, dozens of clinical syndromes, emerging pathogens, rapid evolution of existing pathogens and their associated resistance mechanisms, and the absence of gold standards in many situations. In spite of these challenges, the importance and value of diagnostics cannot be underestimated. Therefore, the Antibacterial Resistance Leadership Group has identified diagnostics as 1 of 4 major areas of emphasis. Herein, we provide an overview of that development, highlighting several examples where innovation in study design, content, and execution is advancing the field of infectious diseases diagnostics. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Polarimetry diagnostic on OMEGA EP using a 10-ps, 263-nm probe beam.
Davies, A; Haberberger, D; Boni, R; Ivancic, S; Brown, R; Froula, D H
2014-11-01
A polarimetry diagnostic was built and characterized for magnetic-field measurements in laser-plasma experiments on the OMEGA EP laser. This diagnostic was built into the existing 4ω (263-nm) probe system that employs a 10-ps laser pulse collected with an f/4 imaging system. The diagnostic measures the rotation of the probe beam's polarization. The polarimeter uses a Wollaston prism to split the probe beam into orthogonal polarization components. Spatially localized intensity variations between images indicate polarization rotation. Magnetic fields can be calculated by combining the polarimetry data with the measured plasma density profile obtained from angular filter refractometry.
Simulation of a tangential soft x-ray imaging system.
Battaglia, D J; Shafer, M W; Unterberg, E A; Bell, R E; Hillis, D L; LeBlanc, B P; Maingi, R; Sabbagh, S; Stratton, B C
2010-10-01
Tangentially viewing soft x-ray (SXR) cameras are capable of detecting nonaxisymmetric plasma structures in magnetically confined plasmas. They are particularly useful for studying stationary perturbations or phenomenon that occur on a timescale faster than the plasma rotation period. Tangential SXR camera diagnostics are planned for the DIII-D and NSTX tokamaks to elucidate the static edge magnetic structure during the application of 3D perturbations. To support the design of the proposed diagnostics, a synthetic diagnostic model was developed using the CHIANTI database to estimate the SXR emission. The model is shown to be in good agreement with the measurements from an existing tangential SXR camera diagnostic on NSTX.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartlein, Rick; Hampton, Nigel; Perkel, Josh
2016-02-01
The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach asmore » a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.« less
Development of an intelligent diagnostic system for reusable rocket engine control
NASA Technical Reports Server (NTRS)
Anex, R. P.; Russell, J. R.; Guo, T.-H.
1991-01-01
A description of an intelligent diagnostic system for the Space Shuttle Main Engines (SSME) is presented. This system is suitable for incorporation in an intelligent controller which implements accommodating closed-loop control to extend engine life and maximize available performance. The diagnostic system architecture is a modular, hierarchical, blackboard system which is particularly well suited for real-time implementation of a system which must be repeatedly updated and extended. The diagnostic problem is formulated as a hierarchical classification problem in which the failure hypotheses are represented in terms of predefined data patterns. The diagnostic expert system incorporates techniques for priority-based diagnostics, the combination of analytical and heuristic knowledge for diagnosis, integration of different AI systems, and the implementation of hierarchical distributed systems. A prototype reusable rocket engine diagnostic system (ReREDS) has been implemented. The prototype user interface and diagnostic performance using SSME test data are described.
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.
2004-01-01
The noninvasive techniques of static and dynamic light scattering are emerging as valuable diagnostic tools for the early detection of ocular and systemic diseases. These include corneal abnormalities, pigmentary dispersion syndrome, glaucoma, cataract, diabetic vitreopathy, and possibly macular degeneration. Systemic conditions such as diabetes and possibly Alzheimer's disease can potentially be detected early via ocular tissues. The current state of development of these techniques for application to ophthalmic research and ultimately clinical practice is reviewed. (c) 2004 Society of Photo-Optical Instrumentation Engineers.
Videothoracoscopy in the diagnosis of intrathoracic pathology: early experience.
Waller, D. A.; Hasan, A.; Forty, J.; Morritt, G. N.
1994-01-01
We report our experience using the new technique of videothoracoscopy in the diagnosis of intrathoracic pathology. In the last 12 months, 40 patients (24 male; 16 female) have undergone investigation by this method. Lung biopsy has been performed in 17 patients, pleural biopsy in 20 patients and mediastinal biopsy in three patients. The majority had been referred after other investigations had been inconclusive. All biopsies were diagnostic except one mediastinal biopsy. This early experience suggests that videothoracoscopic biopsy is a well-tolerated technique with high diagnostic yield. PMID:8154806
Dorsolateral frontal lobe epilepsy.
Lee, Ricky W; Worrell, Greg A
2012-10-01
Dorsolateral frontal lobe seizures often present as a diagnostic challenge. The diverse semiologies may not produce lateralizing or localizing signs and can appear bizarre and suggest psychogenic events. Unfortunately, scalp electroencephalographic (EEG) and magnetic resonance imaging (MRI) are often unsatisfactory. It is not uncommon that these traditional diagnostic studies are either unhelpful or even misleading. In some cases, SPECT and positron emission tomography imaging can be an effective tool to identify the origin of seizures. However, these techniques and other emerging techniques all have limitations, and new approaches are needed to improve source localization.
The procedure for isolation of neoplasms on the retina of the eye
NASA Astrophysics Data System (ADS)
Komkova, S. V.
2018-01-01
In operation, a computer diagnostic procedure on the human retina neoplasms. The use of this technique in medical institutions in the operation of the ophthalmic practitioner allows earlv detection of the disease, at periodic inspection of a pictorial pattern of disease progression. The test procedure is performed on a set of real human retinal photographs taken from international STARE database with known diagnoses. Given the numerous experiments which show the possibility of using this technique, developed on the basis of the diagnostic system in a doctor’s office-ophthalmic.
Sager, Monica; Yeat, Nai Chien; Pajaro-Van der Stadt, Stefan; Lin, Charlotte; Ren, Qiuyin; Lin, Jimmy
2015-01-01
Transcriptomic technologies are evolving to diagnose cancer earlier and more accurately to provide greater predictive and prognostic utility to oncologists and patients. Digital techniques such as RNA sequencing are replacing still-imaging techniques to provide more detailed analysis of the transcriptome and aberrant expression that causes oncogenesis, while companion diagnostics are developing to determine the likely effectiveness of targeted treatments. This article examines recent advancements in molecular profiling research and technology as applied to cancer diagnosis, clinical applications and predictions for the future of personalized medicine in oncology.
NASA Technical Reports Server (NTRS)
El-Sum, H. M. A.; Mawardi, O. K.
1973-01-01
Techniques for studying aerodynamic noise generating mechanisms without disturbing the flow in a free field, and in the reverberation environment of the ARC wind tunnel were investigated along with the design and testing of an acoustic antenna with an electronic steering control. The acoustic characteristics of turbojet as a noise source, detection of direct sound from a source in a reverberant background, optical diagnostic methods, and the design characteristics of a high directivity acoustic antenna. Recommendations for further studies are included.
[Role of interventional radiology in diagnosis and management of the painful spine].
Ruiz Santiago, Fernando; Castellano García, María Del Mar; Aparisi Rodríguez, Francisco
2013-05-13
The aim of this article is to perform a general review of the different radiological percutaneous procedures used to diagnose and treat the many causes of back pain. These procedures can be merely diagnostic, such as discography and biopsy, diagnostic and therapeutic, such as epidural and facets injections, or only therapeutic, such as vertebroplasty, decompressive techniques of the intervertebral disk and tumour ablation. We review the indications, advantages and complications of these techniques. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Yu, Zhihao; Miller, Haylea C; Puzon, Geoffrey J; Clowers, Brian H
2017-04-18
Despite comparatively low levels of infection, primary amoebic meningoencephalitis (PAM) induced by Naegleria fowleri is extremely lethal, with mortality rates above 95%. As a thermophile, this organism is often found in moderate-to-warm climates and has the potential to colonize drinking water distribution systems (DWDSs). Current detection approaches require days to obtain results, whereas swift corrective action can maximize the benefit of public health. Presently, there is little information regarding the underlying in situ metabolism for this amoeba but the potential exists to exploit differentially expressed metabolic signatures as a rapid detection technique. This research outlines the biochemical profiles of selected pathogenic and nonpathogenic Naegleria in vitro using an untargeted metabolomics approach to identify a panel of diagnostically meaningful compounds that may enable rapid detection of viable pathogenic N. fowleri and augment results from traditional monitoring approaches.
Diagnosis of growth hormone deficiency in the paediatric and transitional age.
Chinoy, A; Murray, P G
2016-12-01
Growth hormone deficiency is a rare cause of childhood short stature, but one for which treatment exists in the form of recombinant human growth hormone. A diagnosis of growth hormone deficiency is made based on auxology, biochemistry and imaging. Although no diagnostic gold standard exists, growth hormone provocation tests are considered the mainstay of diagnostic investigations. However, these must be interpreted with caution in view of issues with variability and reproducibility, as well as the limited evidence-base for cut-off values used to distinguish growth hormone deficient and non-growth hormone deficient subjects. In addition, nutritional and pubertal status can affect results, with no consensus on the role of priming with sex steroid hormones. Difficulties with assays exist both for growth hormone as well as insulin-like growth factor-1. Pituitary magnetic resonance imaging is a useful diagnostic, and possibly prognostic, aid. Although genetic testing is not routine, the discovery of more relevant mutations makes it an increasingly important investigation. Children with growth hormone deficiency are retested biochemically on completion of growth, to assess whether they remain so into adulthood. Copyright © 2016. Published by Elsevier Ltd.
Sareen, Rateesh; Pandey, C L
2016-01-01
Background: Early diagnosis of lung cancer plays a pivotal role in reducing lung cancer death rate. Cytological techniques are safer, economical and provide quick results. Bronchoscopic washing, brushing and fine needle aspirations not only complement tissue biopsies in the diagnosis of lung cancer but also comparable. Objectives: (1) To find out diagnostic yields of bronchioalveolar lavage, bronchial brushings, FNAC in diagnosis of lung malignancy. (2) To compare relative accuracy of these three cytological techniques. (3) To correlate the cytologic diagnosis with clinical, bronchoscopic and CT findings. (4) Cytological and histopathological correlation of lung lesions. Methods: All the patients who came with clinical or radiological suspicion of lung malignancy in two and a half year period were included in study. Bronchoalveolar lavage was the most common type of cytological specimen (82.36%), followed by CT guided FNAC (9.45%) and bronchial brushings (8.19%). Sensitivity, specificity, positive and negative predictive value for all techniques and correlation with histopathology was done using standard formulas. Results: The most sensitive technique was CT FNAC – (87.25%) followed by brushings (77.78%) and BAL (72.69%). CT FNAC had highest diagnostic yield (90.38%), followed by brushings (86.67%) and BAL (83.67%). Specificity and positive predictive value were 100 % each of all techniques. Lowest false negatives were obtained in CT FNAC (12.5%) and highest in BAL (27.3%). Highest negative predictive value was of BAL 76.95 % followed by BB 75.59% and CT FNAC 70.59%. Conclusion: Before administering antitubercular treatment every effort should be made to rule out malignancy. CT FNAC had highest diagnostic yield among three cytological techniques. BAL is an important tool in screening central as well as in accessible lesions. It can be used at places where CT guided FNAC is not available or could not be done due to technical or financial limitations PMID:27890992
Measurement Techniques for Flow Diagnostic in ITAM Impulse Wind Tunnels
2010-04-01
time of wind - tunnel operation, so that oscillations caused by initial shock loads could decay and a comparatively long time period with constant flow...Flow Diagnostic in ITAM Impulse Wind Tunnels 7 - 4 RTO-EN-AVT-186 A strain-gauge pressure probe is an elastic element (membrane) in a sealed...Diagnostic in ITAM Impulse Wind Tunnels RTO-EN-AVT-186 7 - 5 probes are individually calibrated. Piezoelectric pressure gauges are based
Differential thermal voltammetry for tracking of degradation in lithium-ion batteries
NASA Astrophysics Data System (ADS)
Wu, Billy; Yufit, Vladimir; Merla, Yu; Martinez-Botas, Ricardo F.; Brandon, Nigel P.; Offer, Gregory J.
2015-01-01
Monitoring of lithium-ion batteries is of critical importance in electric vehicle applications in order to manage the operational condition of the cells. Measurements on a vehicle often involve current, voltage and temperature which enable in-situ diagnostic techniques. This paper presents a novel diagnostic technique, termed differential thermal voltammetry, which is capable of monitoring the state of the battery using voltage and temperature measurements in galvanostatic operating modes. This tracks battery degradation through phase transitions, and the resulting entropic heat, occurring in the electrodes. Experiments to monitor battery degradation using the new technique are compared with a pseudo-2D cell model. Results show that the differential thermal voltammetry technique provides information comparable to that of slow rate cyclic voltammetry at shorter timescale and with load conditions easier to replicate in a vehicle.
Dielectrophoresis for Biomedical Sciences Applications: A Review
Abd Rahman, Nurhaslina; Ibrahim, Fatimah; Yafouz, Bashar
2017-01-01
Dielectrophoresis (DEP) is a label-free, accurate, fast, low-cost diagnostic technique that uses the principles of polarization and the motion of bioparticles in applied electric fields. This technique has been proven to be beneficial in various fields, including environmental research, polymer research, biosensors, microfluidics, medicine and diagnostics. Biomedical science research is one of the major research areas that could potentially benefit from DEP technology for diverse applications. Nevertheless, many medical science research investigations have yet to benefit from the possibilities offered by DEP. This paper critically reviews the fundamentals, recent progress, current challenges, future directions and potential applications of research investigations in the medical sciences utilizing DEP technique. This review will also act as a guide and reference for medical researchers and scientists to explore and utilize the DEP technique in their research fields. PMID:28245552
Recent technological advancements in tuberculosis diagnostics - A review.
Gupta, Shagun; Kakkar, Vipan
2018-09-15
Early diagnosis and on-time effective treatment are indispensable for Tuberculosis (TB) control - a life threatening infectious communicable disease. The conventional techniques for diagnosing TB normally take two to three weeks. This delay in diagnosis and further increase in detection complexity due to the emerging risks of XDR-TB (Extensively drug Resistant-TB) and MDR-TB (Multidrug Resistant-TB) are evoking interest of researchers in the field of developing rapid TB detection techniques such as biosensing and other point-of-care (POC) techniques. Biosensing technologies along with the collaboration with nanotechnology have enormous potential to boost the MTB detection and for overall management in clinical diagnosis. A diverse range of portable, sensitive and rapid biosensors based on different signal transducer principles and with different biomarkers detection capabilities have been developed for TB detection in the early stages. Further, a lot of progress has been achieved over the years in developing various point-of-care diagnostic tools including non-molecular methods and molecular techniques. The objective of this study is to present a succinct review of the available TB detection techniques that are either in use or under development. The focus of this review is on the current developments occurred in nano-biosensing technologies. A synopsis of ameliorations in different non-molecular diagnostic tools and progress in the field of molecular techniques along with the role of emerging Lab-on-Chip technology for diagnosing and mitigating the TB consequences have also been presented. Copyright © 2018 Elsevier B.V. All rights reserved.
Hybrid Optical-Ultrasonic Technique for Biomedical Diagnostics
Marcu, L.; Sun, Y.; Stephens, D.; Park, J.; Farwell, D. G.; Shung, K. K.
2010-01-01
We report the development of a diagnostic system combining time-resolved fluorescence spectroscopy and ultrasound backscatter microscopy and its application in diagnosis of tumors and atherosclerotic disease. This system allows for concurrent evaluation of distinct compositional, functional, and micro-anatomical features of normal and diseased tissues. PMID:21918737
Laser Diagnostic System Validation and Ultra-Compact Combustor Characterization
2008-03-01
conventional non-reheat Brayton cycle. An ITB consist of a fueled-cavity type flame holder combined with an injection of air in an angled manner from the...Applied Combustion Diagnostics. New York, NY: Taylor & Francis, 2002. 23. Kohse-Hoinghaus, K. Laser Techniques for the Quantitative
21 CFR 866.5180 - Fecal calprotectin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... immunological test system is an in vitro diagnostic device that consists of reagents used to quantitatively measure, by immunochemical techniques, fecal calprotectin in human stool specimens. The device is intended forin vitro diagnostic use as an aid in the diagnosis of inflammatory bowel diseases (IBD), specifically...
Electrical chips for biological point-of-care detection
USDA-ARS?s Scientific Manuscript database
As the future of health care diagnostics moves toward more portable and personalized techniques, there is immense potential to harness the power of electrical signals for biological sensing and diagnostic applications at the point of care. Electrical biochips can be used to both manipulate and sense...
[Diagnostic hysteroscopy indications and results in Complexo Hospitalario Universitario De Ourense].
Pato-Mosquera, Mónica; Vázquez-Rodríguez, Marta; Pérez-Adán, Marta; García-García, María Jesús; Blanco-Pérez, Susana
2013-07-01
Diagnostic hysteroscopy is an endoscopic technique that allows the evaluation of the endocervical canal and uterine cavity. To evaluate indications, complications and referral to operative hysteroscopy. To analyze the correlation between sonographic display, hysteroscopy findings and histological diagnosis. Retrospective and descriptive study of 904 patients who underwent diagnostic hysteroscopy between January 1, 2008 and June 30, 2012. The most frequent indication was sonographic detection of endometrial polyps (75% were premenopausal and 71.2% postmenopausal). The complication rate associated with the test was 11.4%. The reduction experimented in operative hysteroscopies was from 31.2% in 2008 to 12.2% between January and June 2012. When a polyp or a myoma was detected by sonography, diagnostic hysteroscopy showed them in 64.4% y 62.5% of the cases, respectively. The correlation between hysteroscopic findings and histopathologic diagnosis was 77.7% for normal endometrium, 77.9% for polyps, 17.8% for hyperplasic appearance and 100% for carcinoma suspicion. Diagnostic hysteroscopy is a safe technique that allows small interventions avoiding operative hysteroscopies. There is a good relation between hysteroscopic visual inspection and anatomopathologic diagnosis, but biopsy should be taken except if normal endometrium is visualized.
Laparoscopy to evaluate scrotal edema during peritoneal dialysis.
Haggerty, Stephen P; Jorge, Juaquito M
2013-01-01
Acute scrotal edema is an infrequent complication in patients who undergo continuous ambulatory peritoneal dialysis (CAPD), occurring in 2% to 4% of patients. Inguinal hernia is usually the cause, but the diagnosis is sometimes confusing. Imaging modalities such as computed tomographic peritoneography are helpful but can be equivocal. We have used diagnostic laparoscopy in conjunction with open unilateral or bilateral hernia repair for diagnosis and treatment of peritoneal dialysis (PD) patients with acute scrotal edema. TECHNIQUE AND CASES: Three patients with acute scrotal edema while receiving CAPD over the span of 7 years had inconclusive results at clinical examination and on diagnostic imaging. All patients underwent diagnostic laparoscopy that revealed indirect inguinal hernia, which was concomitantly repaired using an open-mesh technique. Diagnostic laparoscopy revealed the etiology of the scrotal edema 100% of the time, with no complications, and allowed concomitant repair of the hernia. One patient had postoperative catheter outflow obstruction, which was deemed to be unrelated to the hernia repair. Diagnostic laparoscopy is helpful in confirming the source of acute scrotal edema in CAPD patients and can be performed in conjunction with an open-mesh repair with minimal added time or risk.
Combined evaluation of commonly used techniques, including PCR, for diagnosis of mouse fur mites.
Karlsson, Eleanor M; Pearson, Laura M; Kuzma, Kristen M; Burkholder, Tanya H
2014-01-01
Our study evaluated and compared the false-negative rates (FNR) of a wide array of fur-mite diagnostic tests, including 2 postmortem tests (pelt exam and sticky paper) and 3 antemortem tests (adhesive tape, fur pluck, and PCR). Past publications examining fur-mite diagnostic techniques primarily used paired comparisons, evaluating tests by their level of agreement with only one other test. However, different combinations or pairs of diagnostics are used in the different studies, making the results of these comparisons difficult to interpret across all available diagnostics. In the current study, mice from a conventionally maintained colony endemic for Myobia musculi were identified as positive based on at least one positive diagnostic test. From this pool of positive animals, the FNR of all tests were quantified. The PCR assay and the pelt exam performed the best, with 0% and 2% FNR respectively, whereas tape, fur-pluck, and sticky-paper tests showed 24%, 26%, and 36% FNR, respectively. Our study shows that for mice in a colony naturally infested with Myobia musculi, PCR testing can be used for reliable antemortem detection, and pelt exam performed by experienced examiners is reliable for postmortem detection.
Tannure, Meire Chucre; Salgado, Patrícia de Oliveira; Chianca, Tânia Couto Machado
2014-01-01
This descriptive study aimed at elaborating nursing diagnostic labels according to ICNP®; conducting a cross-mapping between the diagnostic formulations and the diagnostic labels of NANDA-I; identifying the diagnostic labels thus obtained that were also listed in the NANDA-I; and mapping them according to Basic Human Needs. The workshop technique was applied to 32 intensive care nurses, the cross-mapping and validation based on agreement with experts. The workshop produced 1665 diagnostic labels which were further refined into 120 labels. They were then submitted to a cross-mapping process with both NANDA-I diagnostic labels and the Basic Human Needs. The mapping results underwent content validation by two expert nurses leading to concordance rates of 92% and 100%. It was found that 63 labels were listed in NANDA-I and 47 were not.
Cognitive balanced model: a conceptual scheme of diagnostic decision making.
Lucchiari, Claudio; Pravettoni, Gabriella
2012-02-01
Diagnostic reasoning is a critical aspect of clinical performance, having a high impact on quality and safety of care. Although diagnosis is fundamental in medicine, we still have a poor understanding of the factors that determine its course. According to traditional understanding, all information used in diagnostic reasoning is objective and logically driven. However, these conditions are not always met. Although we would be less likely to make an inaccurate diagnosis when following rational decision making, as described by normative models, the real diagnostic process works in a different way. Recent work has described the major cognitive biases in medicine as well as a number of strategies for reducing them, collectively called debiasing techniques. However, advances have encountered obstacles in achieving implementation into clinical practice. While traditional understanding of clinical reasoning has failed to consider contextual factors, most debiasing techniques seem to fail in raising sound and safer medical praxis. Technological solutions, being data driven, are fundamental in increasing care safety, but they need to consider human factors. Thus, balanced models, cognitive driven and technology based, are needed in day-to-day applications to actually improve the diagnostic process. The purpose of this article, then, is to provide insight into cognitive influences that have resulted in wrong, delayed or missed diagnosis. Using a cognitive approach, we describe the basis of medical error, with particular emphasis on diagnostic error. We then propose a conceptual scheme of the diagnostic process by the use of fuzzy cognitive maps. © 2011 Blackwell Publishing Ltd.
Mobile device for disease diagnosis and data tracking in resource-limited settings.
Chin, Curtis D; Cheung, Yuk Kee; Laksanasopin, Tassaneewan; Modena, Mario M; Chin, Sau Yin; Sridhara, Archana A; Steinmiller, David; Linder, Vincent; Mushingantahe, Jules; Umviligihozo, Gisele; Karita, Etienne; Mwambarangwe, Lambert; Braunstein, Sarah L; van de Wijgert, Janneke; Sahabo, Ruben; Justman, Jessica E; El-Sadr, Wafaa; Sia, Samuel K
2013-04-01
Collection of epidemiological data and care of patients are hampered by lack of access to laboratory diagnostic equipment and patients' health records in resource-limited settings. We engineered a low-cost mobile device that combines cell-phone and satellite communication technologies with fluid miniaturization techniques for performing all essential ELISA functions. We assessed the device's ability to perform HIV serodiagnostic testing in Rwanda and synchronize results in real time with electronic health records. We tested serum, plasma, and whole blood samples collected in Rwanda and on a commercially available sample panel made of mixed antibody titers. HIV testing on 167 Rwandan patients evaluated for HIV, viral hepatitis, and sexually transmitted infections yielded diagnostic sensitivity and specificity of 100% and 99%, respectively. Testing on 40 Rwandan whole-blood samples-using 1 μL of sample per patient-resulted in diagnostic sensitivity and specificity of 100% and 100%. The mobile device also successfully transmitted all whole-blood test results from a Rwandan clinic to a medical records database stored on the cloud. For all samples in the commercial panel, the device produced results in agreement with a leading ELISA test, including detection of weakly positive samples that were missed by existing rapid tests. The device operated autonomously with minimal user input, produced each result 10 times faster than benchtop ELISA, and consumed as little power as a mobile phone. A low-cost mobile device can perform a blood-based HIV serodiagnostic test with laboratory-level accuracy and real-time synchronization of patient health record data. © 2012 American Association for Clinical Chemistry