Sample records for exit control system

  1. Engineering Development Tests Airdrop Controlled Exit System (ACES)

    DTIC Science & Technology

    1980-09-01

    AIRDROP CONTROLLED EXIT SYSTEM ( ACES ) RECOVERY PARACHUTES TELEMETERING DATA 20. D5TFAC c• Cat •u•u am revers e• ift n•ceesafy ad Ide•lityf by block...rTECHNICAL REPORT , NATICK /TR-82 /017 f C’n Engineering Development Tests Airdropý Controlled Exit System ( ACES ) COPY CLV40ble to DTIC doe’ io C...and,50.,,,10) s. TYPE OF REPORT A PERIOn COVEnEo Test Report ENCINEERTNG DEVELOPMENT TESTS Oct 79 - Apr 80 AIRDROP CONTROLLED EXIT SYSTEM ( ACES ) 6

  2. Feedback controlled optics with wavefront compensation

    NASA Technical Reports Server (NTRS)

    Breckenridge, William G. (Inventor); Redding, David C. (Inventor)

    1993-01-01

    The sensitivity model of a complex optical system obtained by linear ray tracing is used to compute a control gain matrix by imposing the mathematical condition for minimizing the total wavefront error at the optical system's exit pupil. The most recent deformations or error states of the controlled segments or optical surfaces of the system are then assembled as an error vector, and the error vector is transformed by the control gain matrix to produce the exact control variables which will minimize the total wavefront error at the exit pupil of the optical system. These exact control variables are then applied to the actuators controlling the various optical surfaces in the system causing the immediate reduction in total wavefront error observed at the exit pupil of the optical system.

  3. 46 CFR 169.745 - Escape hatches and emergency exits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Escape hatches and emergency exits. 169.745 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.745 Escape hatches and emergency exits. Each escape hatch and other emergency exit must be marked on both sides using at least 1...

  4. 46 CFR 169.745 - Escape hatches and emergency exits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Escape hatches and emergency exits. 169.745 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.745 Escape hatches and emergency exits. Each escape hatch and other emergency exit must be marked on both sides using at least 1...

  5. 46 CFR 169.745 - Escape hatches and emergency exits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Escape hatches and emergency exits. 169.745 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.745 Escape hatches and emergency exits. Each escape hatch and other emergency exit must be marked on both sides using at least 1...

  6. 46 CFR 169.745 - Escape hatches and emergency exits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Escape hatches and emergency exits. 169.745 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.745 Escape hatches and emergency exits. Each escape hatch and other emergency exit must be marked on both sides using at least 1...

  7. 46 CFR 169.745 - Escape hatches and emergency exits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Escape hatches and emergency exits. 169.745 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.745 Escape hatches and emergency exits. Each escape hatch and other emergency exit must be marked on both sides using at least 1...

  8. Turbojet-exhaust-nozzle secondary-airflow pumping as an exit control of an inlet-stability bypass system for a Mach 2.5 axisymmetric mixed-compression inlet. [Lewis 10- by 10-ft. supersonic wind tunnel test

    NASA Technical Reports Server (NTRS)

    Sanders, B. W.

    1980-01-01

    The throat of a Mach 2.5 inlet that was attached to a turbojet engine was fitted with large, porous bleed areas to provide a stability bypass system that would allow a large, stable airflow range. Exhaust-nozzle, secondary-airflow pumping was used as the exit control for the stability bypass airflow. Propulsion system response and stability bypass performance were obtained for several transient airflow disturbances, both internal and external. Internal airflow disturbances included reductions in overboard bypass airflow, power lever angle, and primary-nozzle area, as well as compressor stall. Nozzle secondary pumping as a stability bypass exit control can provide the inlet with a large stability margin with no adverse effects on propulsion system performance.

  9. Interferometric rotation sensor

    NASA Technical Reports Server (NTRS)

    Walsh, T. M. (Inventor)

    1973-01-01

    An interferometric rotation sensor and control system is provided which includes a compound prism interferometer and an associated direction control system. Light entering the interferometer is split into two paths with the light in the respective paths being reflected an unequal number of times, and then being recombined at an exit aperture in phase differing relationships. Incoming light is deviated from the optical axis of the device by an angle, alpha. The angle causes a similar displacement of the two component images at the exit aperture which results in a fringe pattern. Fringe numbers are directly related to angle alpha. Various control systems of the interferometer are given.

  10. Pressure activated stability-bypass-control valves to increase the stable airflow range of a Mach 2.5 inlet with 40 percent internal contraction

    NASA Technical Reports Server (NTRS)

    Mitchell, G. A.; Sanders, B. W.

    1974-01-01

    The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. The inlet stable airflow range provided by various stability-bypass entrance configurations in alternate combination with several stability-bypass exit controls was determined for both steady-state conditions and internal transient pulses. Transient results were also obtained for the inlet with a choke point at the diffuser exit. Instart angles of attack were determined for the various stability-bypass entrance configurations. The response of the inlet-coldpipe system to internal and external oscillating disturbances was determined. Poppet valves at the stability-bypass exit provided an inlet stable airflow range of 28 percent or greater at all static and transient conditions.

  11. Reducing Dangerous Nighttime Events in Persons with Dementia Using a Nighttime Monitoring System

    PubMed Central

    Rowe, Meredeth A.; Kelly, Annette; Horne, Claydell; Lane, Steve; Campbell, Judy; Lehman, Brandy; Phipps, Chad; Keller, Meredith; Benito, Andrea Pe

    2009-01-01

    Background Nighttime activity, a common occurrence in persons with dementia, increases the risk for injury and unattended home exits, and impairs the sleep patterns of caregivers. Technology is needed that will alert caregivers of nighttime activity in persons with dementia to help prevent injuries and unattended exits. Methods As part of a product development grant, a randomized pilot study was conducted to test the effectiveness of a new night monitoring system designed for informal caregivers to use in the home. Data from 53 subjects were collected at 9 points in time over a 12-month period regarding injuries and unattended home exits that occurred while the caregiver slept. Nighttime activity frequently resulted in nursing home placement. Results The night monitoring system proved a reliable adjunct to assist caregivers in managing nighttime activity. A total of 9 events (injuries or unattended home exits) occurred during the study with 6 events occurring in the control group. Using intent-to-treat analysis, there was no difference between the groups. However, in a secondary analysis based on use of the intervention, experimental subjects were 85% less likely to sustain an event than control subjects. Conclusion When nighttime activity occurred, it resulted in severe injuries sometimes associated with subsequent nursing home placement. The night monitoring system represents a new technology that caregivers can use to assist them in preventing nighttime injuries and unattended home exits in care recipients with dementia. PMID:19751921

  12. An Automated Temperature Controller for the Advanced Hall Effect Experimental Data Acquisition System.

    DTIC Science & Technology

    1982-03-01

    ENTRY: ACCA CONTAINS THE CHARACTER EXIT: ACCA CONTAINS THE CHARACTER DISPLAY TAilLE UPDATKD DISPLAY POINTER INCREMENTED VOLATILE RECISTERS: B...OUTPUTS THE RIC11T HALF-BYTE OF THE HEX NUMBER CON- TAINED IN ACCA TO THE DISPLAY. ENTRY: ACCA CONTAINS THE HEX NUMBER EXIT: ACCA CONTAINS THE HEX...OUTPUTS THE LEFT HALF-BYTE OF THE HEX NUMBER CON- TAINED IN ACCA TO THE DISPLAY. ENTRY: ACCA CONTAINS THE HEX NUMBER EXIT: ACCA CONTAINS THE HEX

  13. Nonlinear Modeling and Control of a Propellant Mixer

    NASA Technical Reports Server (NTRS)

    Barbieri, Enrique; Richter, Hanz; Figueroa, Fernando

    2003-01-01

    A mixing chamber used in rocket engine combustion testing at NASA Stennis Space Center is modeled by a second order nonlinear MIMO system. The mixer is used to condition the thermodynamic properties of cryogenic liquid propellant by controlled injection of the same substance in the gaseous phase. The three inputs of the mixer are the positions of the valves regulating the liquid and gas flows at the inlets, and the position of the exit valve regulating the flow of conditioned propellant. The outputs to be tracked and/or regulated are mixer internal pressure, exit mass flow, and exit temperature. The outputs must conform to test specifications dictated by the type of rocket engine or component being tested downstream of the mixer. Feedback linearization is used to achieve tracking and regulation of the outputs. It is shown that the system is minimum-phase provided certain conditions on the parameters are satisfied. The conditions are shown to have physical interpretation.

  14. Flow Distribution Control Characteristics in Marine Gas Turbine Waste-Heat Recovery Systems. Phase I. Flow Distribution Characteristics and Control in Diffusers.

    DTIC Science & Technology

    1981-08-01

    provide the lowest rate of momentum outflow and thus yield maximum diffuser efficiency. In their study, Wolf and Johnston (Ref. 1.12) used screens made...other words, the uniform velocity at the diffuser exit implies the lowest exit velocity attainable for a given flow rate and lowest rate of momentum ... momentum , and energy and the equation of state. The procedures of manipulating these partial differential iations into an analytical model for analyzing

  15. Coordinated control strategy for improving the two drops of the wind storage combined system

    NASA Astrophysics Data System (ADS)

    Qian, Zhou; Chenggen, Wang; Jing, Bu

    2018-05-01

    In the power system with high permeability wind power, due to wind power fluctuation, the operation of large-scale wind power grid connected to the system brings challenges to the frequency stability of the system. When the doubly fed wind power generation unit does not reserve spare capacity to participate in the system frequency regulation, the system frequency will produce two drops in different degrees when the wind power exits frequency modulation and enters the speed recovery stage. To solve this problem, based on the complementary advantages of wind turbines and energy storage systems in power transmission and frequency modulation, a wind storage combined frequency modulation strategy based on sectional control is proposed in this paper. Based on the TOP wind power frequency modulation strategy, the wind power output reference value is determined according to the linear relationship between the output and the speed of the wind turbine, and the auxiliary wind power load reduction is controlled when the wind power exits frequency modulation into the speed recovery stage, so that the wind turbine is recovered to run at the optimal speed. Then, according to the system frequency and the wind turbine operation state, set the energy storage system frequency modulation output. Energy storage output active support is triggered during wind speed recovery. And then when the system frequency to return to the normal operating frequency range, reduce energy storage output or to exit frequency modulation. The simulation results verify the effectiveness of the proposed method.

  16. 46 CFR 95.16-5 - Controls.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Controls. 95.16-5 Section 95.16-5 Shipping COAST GUARD... Clean Agent Gas Extinguishing Systems, Details § 95.16-5 Controls. (a) At least one releasing station must be installed near the main entrance/exit to the protected space. (b) System controls must be of an...

  17. 46 CFR 95.16-5 - Controls.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Controls. 95.16-5 Section 95.16-5 Shipping COAST GUARD... Clean Agent Gas Extinguishing Systems, Details § 95.16-5 Controls. (a) At least one releasing station must be installed near the main entrance/exit to the protected space. (b) System controls must be of an...

  18. 46 CFR 95.16-5 - Controls.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Controls. 95.16-5 Section 95.16-5 Shipping COAST GUARD... Clean Agent Gas Extinguishing Systems, Details § 95.16-5 Controls. (a) At least one releasing station must be installed near the main entrance/exit to the protected space. (b) System controls must be of an...

  19. 14 CFR 27.1557 - Miscellaneous markings and placards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...; (iii) For turbine engine powered rotorcraft, the permissible fuel designations; and (iv) For pressure...) Emergency exit placards. Each placard and operating control for each emergency exit must be red. A placard must be near each emergency exit control and must clearly indicate the location of that exit and its...

  20. 14 CFR 27.1557 - Miscellaneous markings and placards.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...; (iii) For turbine engine powered rotorcraft, the permissible fuel designations; and (iv) For pressure...) Emergency exit placards. Each placard and operating control for each emergency exit must be red. A placard must be near each emergency exit control and must clearly indicate the location of that exit and its...

  1. 14 CFR 27.1557 - Miscellaneous markings and placards.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...; (iii) For turbine engine powered rotorcraft, the permissible fuel designations; and (iv) For pressure...) Emergency exit placards. Each placard and operating control for each emergency exit must be red. A placard must be near each emergency exit control and must clearly indicate the location of that exit and its...

  2. 14 CFR 27.1557 - Miscellaneous markings and placards.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...; (iii) For turbine engine powered rotorcraft, the permissible fuel designations; and (iv) For pressure...) Emergency exit placards. Each placard and operating control for each emergency exit must be red. A placard must be near each emergency exit control and must clearly indicate the location of that exit and its...

  3. Fire safety evaluation system for NASA office/laboratory buildings

    NASA Astrophysics Data System (ADS)

    Nelson, H. E.

    1986-11-01

    A fire safety evaluation system for office/laboratory buildings is developed. The system is a life safety grading system. The system scores building construction, hazardous areas, vertical openings, sprinklers, detectors, alarms, interior finish, smoke control, exit systems, compartmentation, and emergency preparedness.

  4. 7. Survivable low frequency communication system pathway, looking east ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Survivable low frequency communication system pathway, looking east - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  5. Poppet valve control of throat stability bypass to increase stable airflow range of a Mach 2.5. inlet with 60 percent internal contraction

    NASA Technical Reports Server (NTRS)

    Mitchell, G. A.; Sanders, B. W.

    1975-01-01

    The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. System variations included several stability bypass entrance configurations. Poppet valves controlled the bypass airflow. The inlet stable airflow range achieved with each configuration was determined for both steady state conditions and internal pulse transients. Results are compared with those obtained without a stability bypass system. Transient results were also obtained for the inlet with a choke point at the diffuser exit and for the inlet with large and small stability bypass plenum volumes. Poppet valves at the stability bypass exit provided the inlet with a stable airflow range of 20 percent or greater at all static and transient conditions.

  6. Bacterial colonization patterns in daily chlorhexidine care at the exit site in peritoneal dialysis patients-A prospective, randomized controlled trial.

    PubMed

    Wang, Hsi-Hao; Hung, Shih-Yuan; Chang, Min-Yu; Lee, Yi-Che; Lin, Hsiu-Fang; Lin, Tsun-Mei; Yang, Su-Pen; Lin, Hsi-Hsun; Yang, Su-Ching; Wang, Jiun-Ling

    2017-01-01

    Bacterial colonization patterns in daily chlorhexidine care at the exit site in peritoneal dialysis (PD) patients were not known. We performed a prospective, randomized controlled trial enrolling 89 PD patients. After stratification by initial Staphylococcus aureus (SA) carrier status, patients were randomly assigned to receive daily 4% chlorhexidine care (intervention group) or normal saline (control group) at the exit site. Monthly, we cultured bacteria from the exit site and nasal swabs for 1 year. The SA colonization rates at exit site at 6 and 12 months were significantly lower in the intervention group than the control group (5.0% vs. 22.9%, p = 0.023 and 8.6% vs. 28.1%, p = 0.037 for 6 and 12 months, respectively). The Methicillin-resistant SA (MRSA) colonization rate at exit site at 6 months was similar (5.7% vs. 2.5%,p = 0.596) in control and intervention group, but significantly lower in the intervention group than the control group at exit site at 12months (0% vs. 12.5%, p = 0.047). The gram-negative bacilli (GNB) colonization rates were similar between the intervention and control groups at 6 and 12 months. Genotyping of all MRSA isolates showed ST (sequence type) 59 was the most predominant clone. In conclusion, chlorhexidine care at the exit site in PD patients may be a good strategy for SA and MRSA decolonization. ClinicalTrials.gov NCT02446158.

  7. Static internal performance of ventral and rear nozzle concepts for short-takeoff and vertical-landing aircraft

    NASA Technical Reports Server (NTRS)

    Re, Richard J.; Carson, George T., Jr.

    1991-01-01

    The internal performance of two exhaust system concepts applicable to single-engine short-take-off and vertical-landing tactical fighter configurations was investigated. These concepts involved blocking (or partially blocking) tailpipe flow to the rear (cruise) nozzle and diverting it through an opening to a ventral nozzle exit for vertical thrust. A set of variable angle vanes at the ventral nozzle exit were used to vary ventral nozzle thrust angle between 45 and 110 deg relative to the positive axial force direction. In the vertical flight mode the rear nozzle (or tailpipe flow to it) was completely blocked. In the transition flight mode flow in the tailpipe was split between the rear and ventral nozzles and the flow was vectored at both exits for aircraft control purposes through this flight regime. In the cruise flight mode the ventral nozzle was sealed and all flow exited through the rear nozzle.

  8. 49 CFR 571.207 - Standard No. 207; Seating systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Motor Vehicle Safety Standards § 571.207 Standard No. 207; Seating systems. S1. Purpose and scope. This... equipped with the device and, if access to the control is required in order to exit from the vehicle, to...

  9. SRB/SLEEC (Solid Rocket Booster/Shingle Lap Extendible Exit Cone) feasibility study, volume 2. Appendix A: Design study for a SLEEC actuation system

    NASA Technical Reports Server (NTRS)

    Thompson, D. S.

    1986-01-01

    The results are presented of a design feasibility study of a self-contained (powered) actuation system for a Shingle Lap Extendible Exit Cone (SLEEC) for Transportation System (STS). The evolution of the SLEEC actuation system design is reviewed, the final design concept is summarized, and the results of the detailed study of the final concept of the actuation system are treated. A conservative design using proven mechanical components was established as a major program priority. The final mechanical design has a very low development risk since the components, which consist of ballscrews, gearing, flexible shaft drives, and aircraft cables, have extensive aerospace applications and a history of proven reliability. The mathematical model studies have shown that little or no power is required to deploy the SLEEC actuation system because acceleration forces and internal pressure from the rocket plume provide the required energies. A speed control brake is incorporated in the design in order to control the rate of deployment.

  10. Multiple stage multiple filter hydrate store

    DOEpatents

    Bjorkman, H.K. Jr.

    1983-05-31

    An improved hydrate store for a metal halogen battery system is disclosed which employs a multiple stage, multiple filter means for separating the halogen hydrate from the liquid used in forming the hydrate. The filter means is constructed in the form of three separate sections which combine to substantially cover the interior surface of the store container. Exit conduit means is provided in association with the filter means for transmitting liquid passing through the filter means to a hydrate former subsystem. The hydrate former subsystem combines the halogen gas generated during the charging of the battery system with the liquid to form the hydrate in association with the store. Relief valve means is interposed in the exit conduit means for controlling the operation of the separate sections of the filter means, such that the liquid flow through the exit conduit means from each of the separate sections is controlled in a predetermined sequence. The three separate sections of the filter means operate in three discrete stages to provide a substantially uniform liquid flow to the hydrate former subsystem during the charging of the battery system. The separation of the liquid from the hydrate causes an increase in the density of the hydrate by concentrating the hydrate along the filter means. 7 figs.

  11. Multiple stage multiple filter hydrate store

    DOEpatents

    Bjorkman, Jr., Harry K.

    1983-05-31

    An improved hydrate store for a metal halogen battery system is disclosed which employs a multiple stage, multiple filter means or separating the halogen hydrate from the liquid used in forming the hydrate. The filter means is constructed in the form of three separate sections which combine to substantially cover the interior surface of the store container. Exit conduit means is provided in association with the filter means for transmitting liquid passing through the filter means to a hydrate former subsystem. The hydrate former subsystem combines the halogen gas generated during the charging of the battery system with the liquid to form the hydrate in association with the store. Relief valve means is interposed in the exit conduit means for controlling the operation of the separate sections of the filter means, such that the liquid flow through the exit conduit means from each of the separate sections is controlled in a predetermined sequence. The three separate sections of the filter means operate in three discrete stages to provide a substantially uniform liquid flow to the hydrate former subsystem during the charging of the battery system. The separation of the liquid from the hydrate causes an increase in the density of the hydrate by concentrating the hydrate along the filter means.

  12. A Design Study of Onboard Navigation and Guidance During Aerocapture at Mars. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Fuhry, Douglas Paul

    1988-01-01

    The navigation and guidance of a high lift-to-drag ratio sample return vehicle during aerocapture at Mars are investigated. Emphasis is placed on integrated systems design, with guidance algorithm synthesis and analysis based on vehicle state and atmospheric density uncertainty estimates provided by the navigation system. The latter utilizes a Kalman filter for state vector estimation, with useful update information obtained through radar altimeter measurements and density altitude measurements based on IMU-measured drag acceleration. A three-phase guidance algorithm, featuring constant bank numeric predictor/corrector atmospheric capture and exit phases and an extended constant altitude cruise phase, is developed to provide controlled capture and depletion of orbital energy, orbital plane control, and exit apoapsis control. Integrated navigation and guidance systems performance are analyzed using a four degree-of-freedom computer simulation. The simulation environment includes an atmospheric density model with spatially correlated perturbations to provide realistic variations over the vehicle trajectory. Navigation filter initial conditions for the analysis are based on planetary approach optical navigation results. Results from a selection of test cases are presented to give insight into systems performance.

  13. 76 FR 77183 - Federal Motor Vehicle Safety Standards; Theft Protection and Rollaway Prevention

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-12

    ...: Attempts to shut down the propulsion system without first moving the gear selection control to the ``park... selection control to ``park'' (for vehicles with a ``park'' position), or exits a vehicle without first... without first moving the gear selection control to the ``park'' position (for vehicles with a ``park...

  14. Evaluation of System Architectures for the Army Aviation Ground Power Unit

    DTIC Science & Technology

    2014-12-01

    this state of operation induces wear that reduces pump life. Variable capacity control methods using a constant displacement pump are drive speed...options for use with constant displacement pumps, the fluid or magnetic coupling devices are the most attractive. Variable frequency control cannot...compressor prior to the combustor. The cmTent system turbine exhaust temperature controls to 1250°F, much higher than the compressor exit

  15. Jet engine nozzle exit configurations and associated systems and methods

    NASA Technical Reports Server (NTRS)

    Mengle, Vinod G. (Inventor)

    2011-01-01

    Nozzle exit configurations and associated systems and methods are disclosed. An aircraft system in accordance with one embodiment includes a jet engine exhaust nozzle having an internal flow surface and an exit aperture, with the exit aperture having a perimeter that includes multiple projections extending in an aft direction. Aft portions of individual neighboring projections are spaced apart from each other by a gap, and a geometric feature of the multiple can change in a monotonic manner along at least a portion of the perimeter.

  16. Jet Engine Nozzle Exit Configurations and Associated Systems and Methods

    NASA Technical Reports Server (NTRS)

    Mengle, Vinod G. (Inventor)

    2013-01-01

    Nozzle exit configurations and associated systems and methods are disclosed. An aircraft system in accordance with one embodiment includes a jet engine exhaust nozzle having an internal flow surface and an exit aperture, with the exit aperture having a perimeter that includes multiple projections extending in an aft direction. Aft portions of individual neighboring projections are spaced apart from each other by a gap, and a geometric feature of the multiple can change in a monotonic manner along at least a portion of the perimeter.

  17. 43. Upper level, left to rightground missile guidance system liquid ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. Upper level, left to right--ground missile guidance system liquid cooling equipment, guidance and control coupler rack, programmer group - Ellsworth Air Force Base, Delta Flight, Launch Facility, On County Road T512, south of Exit 116 off I-90, Interior, Jackson County, SD

  18. 40 CFR 264.1033 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... condenser exit (i.e., product side). (vii) For a carbon adsorption system that regenerates the carbon bed... requirements of this section. (g) An owner or operator using a -carbon adsorption system such as a fixed-bed...)(F). (h) An owner or operator using a carbon adsorption system such as a carbon canister that does...

  19. 14 CFR 25.809 - Emergency exit arrangement.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...

  20. 14 CFR 25.809 - Emergency exit arrangement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...

  1. 14 CFR 25.809 - Emergency exit arrangement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...

  2. 14 CFR 25.809 - Emergency exit arrangement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...

  3. Mission Control Center (MCC) system specification for the shuttle Orbital Flight Test (OFT) timeframe

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The Mission Control Center Shuttle (MCC) Shuttle Orbital Flight Test (OFT) Data System (OFTDS) provides facilities for flight control and data systems personnel to monitor and control the Shuttle flights from launch (tower clear) to rollout (wheels stopped on runway). It also supports the preparation for flight (flight planning, flight controller and crew training, and integrated vehicle and network testing activities). The MCC Shuttle OFTDS is described in detail. Three major support systems of the OFTDS and the data types and sources of data entering or exiting the MCC were illustrated. These systems are the communication interface system, the data computation complex, and the display and control system.

  4. 29 CFR 1918.86 - Roll-on roll-off (Ro-Ro) operations (see also § 1918.2, Ro-Ro operations, and § 1918.25).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., Ro-Ro operations, and § 1918.25). 9 [Reserved] (a) Traffic control system. An organized system of vehicular and pedestrian traffic control shall be established and maintained at each entrance/exit ramp and on ramps within the vessel as traffic flow warrants. (b) Ramp load limit. Each ramp shall be plainly...

  5. 29 CFR 1918.86 - Roll-on roll-off (Ro-Ro) operations (see also § 1918.2, Ro-Ro operations, and § 1918.25).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., Ro-Ro operations, and § 1918.25). 9 [Reserved] (a) Traffic control system. An organized system of vehicular and pedestrian traffic control shall be established and maintained at each entrance/exit ramp and on ramps within the vessel as traffic flow warrants. (b) Ramp load limit. Each ramp shall be plainly...

  6. 29 CFR 1918.86 - Roll-on roll-off (Ro-Ro) operations (see also § 1918.2, Ro-Ro operations, and § 1918.25).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., Ro-Ro operations, and § 1918.25). 9 [Reserved] (a) Traffic control system. An organized system of vehicular and pedestrian traffic control shall be established and maintained at each entrance/exit ramp and on ramps within the vessel as traffic flow warrants. (b) Ramp load limit. Each ramp shall be plainly...

  7. Bluff Body Fuel Mixer

    NASA Technical Reports Server (NTRS)

    Cheung, Albert K. (Inventor); Hoke, James B. (Inventor); McKinney, Randal G. (Inventor)

    2017-01-01

    A combustor is provided. The combustor may include an axial fuel injection system, and a radial fuel injection system aft of the axial fuel injection system. The axial fuel injection system includes a mixer having a bluff body at an exit port of the mixer, and a fuel injector disposed within the mixer. A fuel and air mixer is also provided and comprises an outer housing with an exit port and a bluff body. The bluff body extends across the exit port of the outer housing. A fuel injection system is also provided. The systems comprise a mixer having a bluff body at an exit port of the mixer and a fuel injector disposed within the mixer.

  8. Exit interviews to reduce turnover amongst healthcare professionals.

    PubMed

    Flint, Anndrea; Webster, Joan

    2013-03-28

    Exit interviews are widely used in healthcare organisations to identify reasons for staff attrition, yet their usefulness in limiting turnover is unclear. To determine the effectiveness of various exit interview strategies in decreasing turnover rates amongst healthcare professionals. We searched the Cochrane EPOC Group Specialised Register; Cochrane Central Register of Controlled Trials (CENTRAL), Issue 11, 2012; MEDLINE, Ovid (1950- ); EMBASE, Ovid (1947- ); CINAHL, EbscoHost (1980- ), and PsycINFO, OVID (1806-) between October 31 and November 6, 2012. We also screened the reference lists of included studies and relevant reviews; and searched trial registries for planned and on-going trials. We did not restrict searches by language or publication date. Randomised controlled trials, controlled clinical trials, controlled before-after studies and interrupted time series studies comparing turnover rates between healthcare professionals who had undergone one form of exit interview with another form of exit interview or with no interview. Two review authors independently assessed trial quality and extracted data. The original search identified 1560 citations, of which we considered 19 potentially relevant. The two authors independently reviewed the abstracts of these studies and retrieved the full texts of eight studies. We excluded all eight following independent assessment; they were either interviews, commentaries on how to do an exit interview or descriptive studies about reasons for leaving. We found no trials that matched our inclusion criteria. For this first update, we screened 2220 citations and identified no new trials. Evidence about the effectiveness of exit interviews to reduce turnover is currently not available. However, exit interviews may provide useful information about the work environment which, in turn, may be useful in the development of interventions to reduce turnover.

  9. Exit interviews to reduce turnover amongst healthcare professionals.

    PubMed

    Webster, Joan; Flint, Anndrea

    2014-03-15

    Exit interviews are widely used in healthcare organisations to identify reasons for staff attrition, yet their usefulness in limiting turnover is unclear. To determine the effectiveness of various exit interview strategies in decreasing turnover rates amongst healthcare professionals. We searched the Cochrane EPOC Group Specialised Register; Cochrane Central Register of Controlled Trials (CENTRAL), Issue 11, 2012; MEDLINE, Ovid (1950- ); EMBASE, Ovid (1947- ); CINAHL, EbscoHost (1980- ), and PsycINFO, OVID (1806-) between October 31 and November 6, 2012. We also screened the reference lists of included studies and relevant reviews; and searched trial registries for planned and on-going trials. We did not restrict searches by language or publication date. Randomised controlled trials, controlled clinical trials, controlled before-after studies and interrupted time series studies comparing turnover rates between healthcare professionals who had undergone one form of exit interview with another form of exit interview or with no interview. Two review authors independently assessed trial quality and extracted data. The original search identified 1560 citations, of which we considered 19 potentially relevant. The two authors independently reviewed the abstracts of these studies and retrieved the full texts of eight studies. We excluded all eight following independent assessment; they were either interviews, commentaries on how to do an exit interview or descriptive studies about reasons for leaving. We found no trials that matched our inclusion criteria. For this first update, we screened 2220 citations and identified no new trials. Evidence about the effectiveness of exit interviews to reduce turnover is currently not available. However, exit interviews may provide useful information about the work environment which, in turn, may be useful in the development of interventions to reduce turnover.

  10. Exit interviews to reduce turnover amongst healthcare professionals.

    PubMed

    Webster, Joan; Flint, Anndrea

    2014-08-19

    Exit interviews are widely used in healthcare organisations to identify reasons for staff attrition, yet their usefulness in limiting turnover is unclear. To determine the effectiveness of various exit interview strategies in decreasing turnover rates amongst healthcare professionals. We searched the Cochrane EPOC Group Specialised Register; Cochrane Central Register of Controlled Trials (CENTRAL), Issue 11, 2012; MEDLINE, Ovid (1950- ); EMBASE, Ovid (1947- ); CINAHL, EbscoHost (1980- ), and PsycINFO, OVID (1806-) between October 31 and November 6, 2012. We also screened the reference lists of included studies and relevant reviews; and searched trial registries for planned and on-going studies. We did not restrict searches by language or publication date. Randomised controlled trials, controlled clinical trials, controlled before-after studies and interrupted time series studies comparing turnover rates between healthcare professionals who had undergone one form of exit interview with another form of exit interview or with no interview. Two review authors independently assessed trial quality and extracted data. The original search identified 1560 citations, of which we considered 19 potentially relevant. The two authors independently reviewed the abstracts of these studies and retrieved the full texts of eight studies. We excluded all eight following independent assessment; they were either interviews, commentaries on how to do an exit interview or descriptive studies about reasons for leaving. We found no studies that matched our inclusion criteria. For this first update, we screened 2220 citations and identified no new studies. Evidence about the effectiveness of exit interviews to reduce turnover is currently not available. However, exit interviews may provide useful information about the work environment which, in turn, may be useful in the development of interventions to reduce turnover.

  11. The use of the exit interview to reduce turnover amongst healthcare professionals.

    PubMed

    Flint, Anndrea; Webster, Joan

    2011-01-19

    Exit interviews are widely used in healthcare organisations to identify reasons for staff attrition, yet their usefulness in limiting turnover is unclear. To determine the effectiveness of various exit interview strategies in decreasing turnover rates amongst healthcare professionals. We used a comprehensive search strategy including an electronic search of the following databases: DARE, CENTRAL, MEDLINE, EMBASE, CINAHL, PsycINFO, ERIC (search date: 7 September 2010) and EPOC Specialised Register (search date: 30 September 2009). We also screened the reference lists of included studies and relevant reviews. Randomised controlled trials, controlled clinical trials, controlled before and after studies and interrupted time series studies comparing turnover rates between healthcare professionals who had undergone one form of exit interview with another form of exit interview or with no interview. Two review authors independently assessed trial quality and extracted data. The search identified 1560 citations of which we considered 19 potentially relevant. The two authors independently reviewed the abstracts of these studies and retrieved the full texts of eight studies. We excluded all eight following independent assessment. They were either interviews, commentaries on how to do an exit interview or descriptive studies about reasons for leaving. We found no trials that matched our inclusion criteria. Evidence about the effectiveness of exit interviews to reduce turnover is currently not available. However, exit interviews may provide useful information about the work environment which, in turn, may be useful in the development of interventions to reduce turnover.

  12. Inverse heat transfer problem in digital temperature control in plate fin and tube heat exchangers

    NASA Astrophysics Data System (ADS)

    Taler, Dawid; Sury, Adam

    2011-12-01

    The aim of the paper is a steady-state inverse heat transfer problem for plate-fin and tube heat exchangers. The objective of the process control is to adjust the number of fan revolutions per minute so that the water temperature at the heat exchanger outlet is equal to a preset value. Two control techniques were developed. The first is based on the presented mathematical model of the heat exchanger while the second is a digital proportional-integral-derivative (PID) control. The first procedure is very stable. The digital PID controller becomes unstable if the water volumetric flow rate changes significantly. The developed techniques were implemented in digital control system of the water exit temperature in a plate fin and tube heat exchanger. The measured exit temperature of the water was very close to the set value of the temperature if the first method was used. The experiments showed that the PID controller works also well but becomes frequently unstable.

  13. A Hydrogen Peroxide Hot-Jet Simulator for Wind-Tunnel Tests of Turbojet-Exit Models

    NASA Technical Reports Server (NTRS)

    Runckel, Jack F.; Swihart, John M.

    1959-01-01

    A turbojet-engine-exhaust simulator which utilizes a hydrogen peroxide gas generator has been developed for powered-model testing in wind tunnels with air exchange. Catalytic decomposition of concentrated hydrogen peroxide provides a convenient and easily controlled method of providing a hot jet with characteristics that correspond closely to the jet of a gas turbine engine. The problems associated with simulation of jet exhausts in a transonic wind tunnel which led to the selection of a liquid monopropellant are discussed. The operation of the jet simulator consisting of a thrust balance, gas generator, exit nozzle, and auxiliary control system is described. Static-test data obtained with convergent nozzles are presented and shown to be in good agreement with ideal calculated values.

  14. 40 CFR 63.104 - Heat exchange system requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... heat exchange system or at locations where the cooling water enters and exits each heat exchanger or any combination of heat exchangers. (i) For samples taken at the entrance and exit of recirculating... manufacturing process units. (iii) For samples taken at the entrance and exit of each heat exchanger or any...

  15. 33 CFR 161.18 - Reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... call. H HOTEL Date, time and point of entry system Entry time expressed as in (B) and into the entry... KILO Date, time and point of exit from system Exit time expressed as in (B) and exit position expressed....; for a dredge or floating plant: configuration of pipeline, mooring configuration, number of assist...

  16. Higher effort–reward imbalance and lower job control predict exit from the labour market at the age of 61 years or younger: evidence from the English Longitudinal Study of Ageing

    PubMed Central

    Hintsa, T; Kouvonen, A; McCann, M; Jokela, M; Elovainio, M; Demakakos, P

    2015-01-01

    Background We examined whether higher effort–reward imbalance (ERI) and lower job control are associated with exit from the labour market. Methods There were 1263 participants aged 50–74 years from the English Longitudinal Study on Ageing with data on working status and work-related psychosocial factors at baseline (wave 2; 2004–2005), and working status at follow-up (wave 5; 2010–2011). Psychosocial factors at work were assessed using a short validated version of ERI and job control. An allostatic load index was formed using 13 biological parameters. Depressive symptoms were measured using the Center for Epidemiologic Studies Depression Scale. Exit from the labour market was defined as not working in the labour market when 61 years old or younger in 2010–2011. Results Higher ERI OR=1.62 (95% CI 1.01 to 2.61, p=0.048) predicted exit from the labour market independent of age, sex, education, occupational class, allostatic load and depression. Job control OR=0.60 (95% CI 0.42 to 0.85, p=0.004) was associated with exit from the labour market independent of age, sex, education, occupation and depression. The association of higher effort OR=1.32 (95% CI 1.01 to 1.73, p=0.045) with exit from the labour market was independent of age, sex and depression but attenuated to non-significance when additionally controlling for socioeconomic measures. Reward was not related to exit from the labour market. Conclusions Stressful work conditions can be a risk for exiting the labour market before the age of 61 years. Neither socioeconomic position nor allostatic load and depressive symptoms seem to explain this association. PMID:25631860

  17. Higher effort-reward imbalance and lower job control predict exit from the labour market at the age of 61 years or younger: evidence from the English Longitudinal Study of Ageing.

    PubMed

    Hintsa, T; Kouvonen, A; McCann, M; Jokela, M; Elovainio, M; Demakakos, P

    2015-06-01

    We examined whether higher effort-reward imbalance (ERI) and lower job control are associated with exit from the labour market. There were 1263 participants aged 50-74 years from the English Longitudinal Study on Ageing with data on working status and work-related psychosocial factors at baseline (wave 2; 2004-2005), and working status at follow-up (wave 5; 2010-2011). Psychosocial factors at work were assessed using a short validated version of ERI and job control. An allostatic load index was formed using 13 biological parameters. Depressive symptoms were measured using the Center for Epidemiologic Studies Depression Scale. Exit from the labour market was defined as not working in the labour market when 61 years old or younger in 2010-2011. Higher ERI OR=1.62 (95% CI 1.01 to 2.61, p=0.048) predicted exit from the labour market independent of age, sex, education, occupational class, allostatic load and depression. Job control OR=0.60 (95% CI 0.42 to 0.85, p=0.004) was associated with exit from the labour market independent of age, sex, education, occupation and depression. The association of higher effort OR=1.32 (95% CI 1.01 to 1.73, p=0.045) with exit from the labour market was independent of age, sex and depression but attenuated to non-significance when additionally controlling for socioeconomic measures. Reward was not related to exit from the labour market. Stressful work conditions can be a risk for exiting the labour market before the age of 61 years. Neither socioeconomic position nor allostatic load and depressive symptoms seem to explain this association. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. 36 CFR 13.1318 - Location of the EGDA.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Kenai Fjords National Park Exit Glacier Developed... boundary to Exit Glacier Campground Entrance Road, all park areas within 350 meters (383 yards) of the centerline of the Exit Glacier Road; (2) From Exit Glacier Campground Entrance Road to the end of the main...

  19. 36 CFR 13.1318 - Location of the EGDA.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Kenai Fjords National Park Exit Glacier Developed... boundary to Exit Glacier Campground Entrance Road, all park areas within 350 meters (383 yards) of the centerline of the Exit Glacier Road; (2) From Exit Glacier Campground Entrance Road to the end of the main...

  20. 36 CFR 13.1318 - Location of the EGDA.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Kenai Fjords National Park Exit Glacier Developed... boundary to Exit Glacier Campground Entrance Road, all park areas within 350 meters (383 yards) of the centerline of the Exit Glacier Road; (2) From Exit Glacier Campground Entrance Road to the end of the main...

  1. The impact of ill health on exit from paid employment in Europe among older workers.

    PubMed

    van den Berg, Tilja; Schuring, Merel; Avendano, Mauricio; Mackenbach, Johan; Burdorf, Alex

    2010-12-01

    To determine the impact of ill health on exit from paid employment in Europe among older workers. Participants of the Survey on Health and Ageing in Europe (SHARE) in 11 European countries in 2004 and 2006 were selected when 50-63 years old and in paid employment at baseline (n=4611). Data were collected on self-rated health, chronic diseases, mobility limitations, obesity, smoking, alcohol use, physical activity and work characteristics. Participants were classified into employed, retired, unemployed and disabled at the end of the 2-year follow-up. Multinomial logistic regression was used to estimate the effect of different measures of ill health on exit from paid employment. During the 2-year follow-up, 17% of employed workers left paid employment, mainly because of early retirement. Controlling for individual and work related characteristics, poor self-perceived health was strongly associated with exit from paid employment due to retirement, unemployment or disability (ORs from 1.32 to 4.24). Adjustment for working conditions and lifestyle reduced the significant associations between ill health and exit from paid employment by 0-18.7%. Low education, obesity, low job control and effort-reward imbalance were associated with measures of ill health, but also risk factors for exit from paid employment after adjustment for ill health. Poor self-perceived health was strongly associated with exit from paid employment among European workers aged 50-63 years. This study suggests that the influence of ill health on exit from paid employment could be lessened by measures targeting obesity, problematic alcohol use, job control and effort-reward balance.

  2. 36 CFR 13.1326 - Snowmachines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Kenai Fjords National Park Exit Glacier Developed...) On Exit Glacier Road; (b) In parking areas; (c) On a designated route through the Exit Glacier...

  3. 36 CFR 13.1326 - Snowmachines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Kenai Fjords National Park Exit Glacier Developed...) On Exit Glacier Road; (b) In parking areas; (c) On a designated route through the Exit Glacier...

  4. 36 CFR 13.1326 - Snowmachines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Kenai Fjords National Park Exit Glacier Developed...) On Exit Glacier Road; (b) In parking areas; (c) On a designated route through the Exit Glacier...

  5. 36 CFR 13.1326 - Snowmachines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Kenai Fjords National Park Exit Glacier Developed...) On Exit Glacier Road; (b) In parking areas; (c) On a designated route through the Exit Glacier...

  6. Guidance and Control Design for High-Speed Rollout and Turnoff (ROTO)

    NASA Technical Reports Server (NTRS)

    Goldthorpe, S. H.; Dangaran, R. D.; Dwyer, J. P.; McBee, L. S.; Norman, R. M.; Shannon, J. H.; Summers, L. G.

    1996-01-01

    A ROTO architecture, braking and steering control law and display designs for a research high speed Rollout and Turnoff (ROTO) system applicable to transport class aircraft are described herein. Minimum surface friction and FMS database requirements are also documented. The control law designs were developed with the aid of a non-real time simulation program incorporating airframe and gear dynamics as well as steering and braking guidance algorithms. An attainable objective of this ROTO system, as seen from the results of this study, is to assure that the studied aircraft can land with runway occupancy times less then 53 seconds. Runway occupancy time is measured from the time the aircraft crosses the runway threshold until its wing tip clears the near side of the runway. Turnoff ground speeds of 70 knots onto 30 degree exits are allowed with dry and wet surface conditions. Simulation time history and statistical data are documented herein. Parameters which were treated as variables in the simulation study include aircraft touchdown weight/speed/location, aircraft CG, runway friction, sensor noise and winds. After further design and development of the ROTO control system beyond the system developed earlier, aft CG MD-11 aircraft no longer require auto-asymmetric braking (steering) and fly-by-wire nose gear steering. However, the auto ROTO nose gear hysteresis must be less than 2 degrees. The 2 sigma dispersion certified for MD-11 CATIIIB is acceptable. Using this longitudinal dispersion, three ROTO exits are recommended at 3300, 4950 and 6750 feet past the runway threshold. The 3300 foot exit is required for MD-81 class aircraft. Designs documented in this report are valid for the assumptions/models used in this simulation. It is believed that the results will apply to the general class of transport aircraft; however further effort is required to validate this assumption for the general case.

  7. Pulsed hydrojet

    DOEpatents

    Bohachevsky, I.O.; Torrey, M.D.

    1986-06-10

    An underwater pulsed hydrojet propulsion system is provided for accelerating and propelling a projectile or other vessel. A reactant, such as lithium, is fluidized and injected into a water volume. The resulting reaction produces an energy density in a time effective to form a steam pocket. Thrust flaps or baffles direct the pressure from the steam pocket toward an exit nozzle for accelerating a water volume to create thrust. A control system regulates the dispersion of reactant to control thrust characteristics.

  8. How to Enter, Fly In, and Exit the A-Train Constellation

    NASA Technical Reports Server (NTRS)

    Vincent, Mark A.

    2015-01-01

    The collaborative science obtained from the satellites in the A-Train is an unparalleled success. The constellation framework that has evolved is well-formulated and documented by its international members. Communication between teams is enhanced by a web-based Constellation Coordination System. Safety and correlated observations are ensured by defining independent control boxes with buffers in between. Each mission stays within its control box by regular drag makeup maneuvers. Annual inclination adjustments are coordinated by all missions to maintain their absolute and relative Mean Local Time of Ascending Node (MLTAN). Since the satellites are in different orbit planes their separation involves a three-dimensional triad made up of the along track separations, reference groundtracks and MLTAN's. For further safety, a Constellation Envelope has been defined to determine safe entry and exit orbits.

  9. Differences in Student Achievement between Early-Exit and Late-Exit Bilingual Programs: A Multiyear, Statewide Investigation

    ERIC Educational Resources Information Center

    Martinez, Rosa Maria

    2014-01-01

    Purpose The purpose of this study was to examine the difference between two bilingual program types: traditional early-exit and late-exit bilingual programs and academic achievement using archival data from the Texas Education Agency Public Education Information Management System. An examination of academic achievement rates across a 3-year period…

  10. Exit Examinations, Peer Academic Climate, and Adolescents' Developmental Outcomes

    ERIC Educational Resources Information Center

    Benner, Aprile D.

    2013-01-01

    Implications of high school exit examination performance were examined with a sample of 672 racial/ethnic minority students. Exit examination failure in the 10th grade was negatively linked to subsequent grade point average, school engagement, and school belonging one year later, controlling for outcomes prior to taking the examination.…

  11. Translations on Environmental Quality, Number 148

    DTIC Science & Technology

    1977-10-03

    Article 9. Designs for gas filtering installations must include the proper control and automation facilities as per articles 16 and 17. Article 10...mandatorily equipped with: 1. Locking armature at the gas entrance and exit with manual or remote control flanges for the installation of end-caps in...instruments shall be mounted on the control panel of the gas filtering system or the control panel for the technological process. Article 17. (1) The gas

  12. Construction of an easy-to-use CRISPR-Cas9 system by patching a newly designed EXIT circuit.

    PubMed

    Tang, Qiang; Lou, Chunbo; Liu, Shuang-Jiang

    2017-01-01

    Plasmid-borne genetic editing tools, including the widely used CRISPR-Cas9 system, have greatly facilitated bacterial programming to obtain novel functionalities. However, the lack of effective post-editing plasmid elimination methods impedes follow-up genetic manipulation or application. Conventional strategies including exposure to physical and chemical treatments, or exploiting temperature-sensitive replication origins have several drawbacks (e.g., they are limited for efficiency and are time-consuming). Therefore, the demand is apparent for easy and rapid elimination of the tool plasmids from their bacterial hosts after genetic manipulation. To bridge this gap, we designed a novel EXIT circuit with the homing endonuclease, which can be exploited for rapid and efficient elimination of various plasmids with diverse replication origins. As a proof of concept, we validated the EXIT circuit in Escherichia coli by harnessing homing endonuclease I- Sce I and its cleavage site. When integrated into multiple plasmids with different origins, the EXIT circuit allowed them to be eliminated from the host cells, simultaneously. By combining the widely used plasmid-borne CRISPR-Cas9 system and the EXIT circuit, we constructed an easy-to-use CRISPR-Cas9 system that eliminated the Cas9- and the single-guide RNA (sgRNA)-encoding plasmids in one-step. Within 3 days, we successfully constructed an atrazine-degrading E. coli strain, thus further demonstrating the advantage of this new CRISPR-Cas9 system for bacterial genome editing. Our novel EXIT circuit, which exploits the homing endonuclease I- Sce I, enables plasmid(s) with different replication origins to be eliminated from their host cells rapidly and efficiently. We also developed an easy-to-use CRISPR-Cas9 system with the EXIT circuit, and this new system can be widely applied to bacterial genome editing.

  13. A battery-less and wireless wearable sensor system for identifying bed and chair exits in a pilot trial in hospitalized older people.

    PubMed

    Shinmoto Torres, Roberto L; Visvanathan, Renuka; Abbott, Derek; Hill, Keith D; Ranasinghe, Damith C

    2017-01-01

    Falls in hospitals are common, therefore strategies to minimize the impact of these events in older patients and needs to be examined. In this pilot study, we investigate a movement monitoring sensor system for identifying bed and chair exits using a wireless wearable sensor worn by hospitalized older patients. We developed a movement monitoring sensor system that recognizes bed and chair exits. The system consists of a machine learning based activity classifier and a bed and chair exit recognition process based on an activity score function. Twenty-six patients, aged 71 to 93 years old, hospitalized in the Geriatric Evaluation and Management Unit participated in the supervised trials. They wore over their attire a battery-less, lightweight and wireless sensor and performed scripted activities such as getting off the bed and chair. We investigated the system performance in recognizing bed and chair exits in hospital rooms where RFID antennas and readers were in place. The system's acceptability was measured using two surveys with 0-10 likert scales. The first survey measured the change in user perception of the system before and after a trial; the second survey, conducted only at the end of each trial, measured user acceptance of the system based on a multifactor sensor acceptance model. The performance of the system indicated an overall recall of 81.4%, precision of 66.8% and F-score of 72.4% for joint bed and chair exit recognition. Patients demonstrated improved perception of the system after use with overall score change from 7.8 to 9.0 and high acceptance of the system with score ≥ 6.7 for all acceptance factors. The present pilot study suggests the use of wireless wearable sensors is feasible for detecting bed and chair exits in a hospital environment.

  14. Jet engine nozzle exit configurations, including projections oriented relative to pylons, and associated systems and methods

    NASA Technical Reports Server (NTRS)

    Mengle, Vinod G. (Inventor); Thomas, Russell H. (Inventor)

    2012-01-01

    Nozzle exit configurations and associated systems and methods are disclosed. An aircraft system in accordance with one embodiment includes a jet engine exhaust nozzle having an internal flow surface and an exit aperture, with the exit aperture having a perimeter that includes multiple projections extending in an aft direction. Aft portions of individual neighboring projections are spaced apart from each other by a gap, and a geometric feature of the multiple can change in a monotonic manner along at least a portion of the perimeter. Projections near a support pylon and/or associated heat shield can have particular configurations, including greater flow immersion than other projections.

  15. A Matlab-Based Graphical User Interface for Simulation and Control Design of a Hydrogen Mixer

    NASA Technical Reports Server (NTRS)

    Richter, Hanz; Figueroa, Fernando

    2003-01-01

    A Graphical User Interface (GUI) that facilitates prediction and control design tasks for a propellant mixer is described. The Hydrogen mixer is used in rocket test stand operations at the NASA John C. Stennis Space Center. The mixer injects gaseous hydrogen (GH2) into a stream of liquid hydrogen (LH2) to obtain a combined flow with desired thermodynamic properties. The flows of GH2 and LH2 into the mixer are regulated by two control valves, and a third control valve is installed at the exit of the mixer to regulate the combined flow. The three valves may be simultaneously operated in order to achieve any desired combination of total flow, exit temperature and mixer pressure within the range of operation. The mixer, thus, constitutes a three-input, three-output system. A mathematical model of the mixer has been obtained and validated with experimental data. The GUI presented here uses the model to predict mixer response under diverse conditions.

  16. Control strategy for a variable-speed wind energy conversion system

    NASA Technical Reports Server (NTRS)

    Jacob, A.; Veillette, D.; Rajagopalan, V.

    1979-01-01

    A control concept for a variable-speed wind energy conversion system is proposed, for which a self-exited asynchronous cage generator is used along with a system of thyristor converters. The control loops are the following: (1) regulation of the entrainment speed as function of available mechanical energy by acting on the resistance couple of the asynchronous generator; (2) control of electric power delivered to the asynchronous machine, functioning as a motor, for start-up of the vertical axis wind converter; and (3) limitation of the slip value, and by consequence, of the induction currents in the presence of sudden variations of input parameters.

  17. Efficacy and safety of conversion to monotherapy with eslicarbazepine acetate in adults with uncontrolled partial-onset seizures: a randomized historical-control phase III study based in North America.

    PubMed

    Sperling, Michael R; Harvey, Jay; Grinnell, Todd; Cheng, Hailong; Blum, David

    2015-04-01

    To assess the efficacy and safety of eslicarbazepine acetate (ESL) as monotherapy in North American patients with partial-onset seizures (POS). This multicenter, randomized, double-blind "withdrawal to monotherapy" study used historical control data as the comparator. Adults with POS medically uncontrolled by one to two antiepileptic drugs gradually converted to ESL monotherapy. Following an 8-week baseline period, patients were randomized 2:1 to receive ESL 1,600 mg (n = 128) or 1,200 mg QD (n = 65) for 18 weeks. The primary end point was the proportion of patients meeting predefined exit criteria (signifying worsening seizure control). Treatment was considered effective if the 95% upper confidence limit (UCL) for the Kaplan-Meier estimated exit rate was lower than the exit rate threshold calculated from the historical control (65.3%). Kaplan-Meier estimated exit rates were: ESL 1,600 mg, 28.7% (95% CI 21.2-38.1%) and 1,200 mg, 44.4% (32.5-58.3%). The difference between doses was not significant (p = 0.07). For both doses, the 95% UCLs for the exit rate were ˂ 65.3%; ESL monotherapy was considered superior to the historical control. There was no statistically significant increase in the risk of study exit related to carbamazepine use. Nine (7.6%) and five patients (8.3%) remained seizure-free during the 10-week monotherapy period, while taking ESL 1,600 and 1,200 mg, respectively. The reductions in median standardized seizure frequency (seizures per 28 days) between baseline and the 18-week treatment period were: ESL 1,600 mg, 42% and 1,200 mg, 31%. Treatment-emergent adverse events (TEAEs) occurring in ≥ 10% of patients were dizziness, headache, fatigue, somnolence, nausea, and nasopharyngitis. The TEAE most frequently leading to discontinuation was hyponatremia (2.1%). ESL was efficacious and well tolerated as monotherapy in North American patients, and led to a reduction in seizure frequency. Exit rates for ESL 1,600 and 1,200 mg QD were superior to the historical control; the difference in exit rates between doses was not statistically significant. © 2015 The Authors. Epilepsia published by Wiley Periodicals, Inc. on behalf of International League Against Epilepsy.

  18. 75 FR 48412 - Proposed Information Collection (Six-Month Post-Exit Focus Interview of Former VHA Employees...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-10

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-New (VA Form 10-0487)] Proposed Information Collection (Six-Month Post-Exit Focus Interview of Former VHA Employees) Activities; Under OMB Review AGENCY...).'' SUPPLEMENTARY INFORMATION: Title: Six-Month Post-Exit Focus Interview of Former VHA Employees, VA Form 10-0487...

  19. A battery-less and wireless wearable sensor system for identifying bed and chair exits in a pilot trial in hospitalized older people

    PubMed Central

    Visvanathan, Renuka; Abbott, Derek; Hill, Keith D.; Ranasinghe, Damith C.

    2017-01-01

    Falls in hospitals are common, therefore strategies to minimize the impact of these events in older patients and needs to be examined. In this pilot study, we investigate a movement monitoring sensor system for identifying bed and chair exits using a wireless wearable sensor worn by hospitalized older patients. We developed a movement monitoring sensor system that recognizes bed and chair exits. The system consists of a machine learning based activity classifier and a bed and chair exit recognition process based on an activity score function. Twenty-six patients, aged 71 to 93 years old, hospitalized in the Geriatric Evaluation and Management Unit participated in the supervised trials. They wore over their attire a battery-less, lightweight and wireless sensor and performed scripted activities such as getting off the bed and chair. We investigated the system performance in recognizing bed and chair exits in hospital rooms where RFID antennas and readers were in place. The system’s acceptability was measured using two surveys with 0–10 likert scales. The first survey measured the change in user perception of the system before and after a trial; the second survey, conducted only at the end of each trial, measured user acceptance of the system based on a multifactor sensor acceptance model. The performance of the system indicated an overall recall of 81.4%, precision of 66.8% and F-score of 72.4% for joint bed and chair exit recognition. Patients demonstrated improved perception of the system after use with overall score change from 7.8 to 9.0 and high acceptance of the system with score ≥ 6.7 for all acceptance factors. The present pilot study suggests the use of wireless wearable sensors is feasible for detecting bed and chair exits in a hospital environment. PMID:29016696

  20. 14 CFR 29.1557 - Miscellaneous markings and placards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...; (iii) For turbine-engine-powered rotorcraft, the permissible fuel designations, except that if... placard and operating control for each emergency exit must differ in color from the surrounding fuselage surface as prescribed in § 29.811(h)(2). A placard must be near each emergency exit control and must...

  1. 14 CFR 29.1557 - Miscellaneous markings and placards.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...; (iii) For turbine-engine-powered rotorcraft, the permissible fuel designations, except that if... placard and operating control for each emergency exit must differ in color from the surrounding fuselage surface as prescribed in § 29.811(h)(2). A placard must be near each emergency exit control and must...

  2. 14 CFR 29.1557 - Miscellaneous markings and placards.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...; (iii) For turbine-engine-powered rotorcraft, the permissible fuel designations, except that if... placard and operating control for each emergency exit must differ in color from the surrounding fuselage surface as prescribed in § 29.811(h)(2). A placard must be near each emergency exit control and must...

  3. 14 CFR 29.1557 - Miscellaneous markings and placards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...; (iii) For turbine-engine-powered rotorcraft, the permissible fuel designations, except that if... placard and operating control for each emergency exit must differ in color from the surrounding fuselage surface as prescribed in § 29.811(h)(2). A placard must be near each emergency exit control and must...

  4. 14 CFR 29.1557 - Miscellaneous markings and placards.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...; (iii) For turbine-engine-powered rotorcraft, the permissible fuel designations, except that if... placard and operating control for each emergency exit must differ in color from the surrounding fuselage surface as prescribed in § 29.811(h)(2). A placard must be near each emergency exit control and must...

  5. A Summary of the Development of a Nominal Land Landing Airbag Impact Attenuation System for the Orion Crew Module

    NASA Technical Reports Server (NTRS)

    Tutt, Ben; Gill, Susannah; Wilson, Aaron; Johnson, Keith

    2009-01-01

    Airborne Systems North America (formally Irvin Aerospace Inc) has developed an Airbag Landing System for the Orion Crew Module of the Crew Exploration Vehicle. This work is in support of the NASA Langley Research Center Landing System Advanced Development Project. Orion is part of the Constellation Program to send human explorers back to the moon, and then onwards to Mars and other destinations in the Solar System. A component of the Vision for Space Exploration, Orion is being developed to also enable access to space following the retirement of the Space Shuttle in the next decade. This paper documents the development of a conceptual design, fabrication of prototype assemblies, component level testing and two generations of airbag landing system testing. The airbag system has been designed and analyzed using the transient dynamic finite element code LS-DYNA(RegisteredTradeMark). The landing system consists of six airbag assemblies; each assembly comprising a primary impact venting airbag and a non-venting anti-bottoming airbag. The anti-bottoming airbag provides ground clearance following the initial impact attenuation sequence. Incorporated into each primary impact airbag is an active vent that allows the entrapped gas to exit the control volume. The size of the vent is tailored to control the flow-rate of the exiting gas. An internal shaping structure is utilized to control the shape of the primary or main airbags prior to ground impact; this significantly improves stroke efficiency and performance.

  6. 40 CFR 264.1033 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... § 264.1035(b)(4)(iii)(F). (h) An owner or operator using a carbon adsorption system such as a carbon...). (iii) A steam-assisted or nonassisted flare designed for and operated with an exit velocity, as... established as a requirement of § 264.1035(b)(4)(iii)(G), whichever is longer. (2) Replace the existing carbon...

  7. 40 CFR 264.1033 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... § 264.1035(b)(4)(iii)(F). (h) An owner or operator using a carbon adsorption system such as a carbon...). (iii) A steam-assisted or nonassisted flare designed for and operated with an exit velocity, as... established as a requirement of § 264.1035(b)(4)(iii)(G), whichever is longer. (2) Replace the existing carbon...

  8. 40 CFR 264.1033 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... § 264.1035(b)(4)(iii)(F). (h) An owner or operator using a carbon adsorption system such as a carbon...). (iii) A steam-assisted or nonassisted flare designed for and operated with an exit velocity, as... established as a requirement of § 264.1035(b)(4)(iii)(G), whichever is longer. (2) Replace the existing carbon...

  9. Effectiveness of a Batteryless and Wireless Wearable Sensor System for Identifying Bed and Chair Exits in Healthy Older People

    PubMed Central

    Shinmoto Torres, Roberto Luis; Visvanathan, Renuka; Hoskins, Stephen; van den Hengel, Anton; Ranasinghe, Damith C.

    2016-01-01

    Aging populations are increasing worldwide and strategies to minimize the impact of falls on older people need to be examined. Falls in hospitals are common and current hospital technological implementations use localized sensors on beds and chairs to alert caregivers of unsupervised patient ambulations; however, such systems have high false alarm rates. We investigate the recognition of bed and chair exits in real-time using a wireless wearable sensor worn by healthy older volunteers. Fourteen healthy older participants joined in supervised trials. They wore a batteryless, lightweight and wireless sensor over their attire and performed a set of broadly scripted activities. We developed a movement monitoring approach for the recognition of bed and chair exits based on a machine learning activity predictor. We investigated the effectiveness of our approach in generating bed and chair exit alerts in two possible clinical deployments (Room 1 and Room 2). The system obtained recall results above 93% (Room 2) and 94% (Room 1) for bed and chair exits, respectively. Precision was >78% and 67%, respectively, while F-score was >84% and 77% for bed and chair exits, respectively. This system has potential for real-time monitoring but further research in the final target population of older people is necessary. PMID:27092506

  10. Integrated Display System for Low Visibility Landing and Surface Operations

    NASA Technical Reports Server (NTRS)

    Beskenis, Sharon Otero; Green, David F., Jr.; Hyer, Paul V.; Johnson, Edward J., Jr.

    1998-01-01

    This report summarizes the software products and system architectures developed by Lockheed Martin in support of the Low Visibility Landing and Surface Operations (LVLASO) program at NASA Langley Research Center. It presents an overview of the technical aspects, capabilities, and system integration issues associated with an integrated display system (IDS) that collects, processes and presents information to an aircraft flight crew during all phases of landing, roll-out, turn-off, inbound taxi, outbound taxi and takeoff. Communications hardware, drivers, and software provide continuous real-time data at varying rates and from many different sources to the display programs for presentation on a head-down display (HDD) and/or a head-up display (HUD). An electronic moving map of the airport surface is implemented on the HDD which includes the taxi route assigned by air traffic control, a text messaging system, and surface traffic and runway status information. Typical HUD symbology for navigation and control of the aircraft is augmented to provide aircraft deceleration guidance after touchdown to a pilot selected exit and taxi guidance along the route assigned by ATC. HUD displays include scene-linked symbolic runways, runway exits and taxiways that are conformal with the actual locations on the airport surface. Display formats, system architectures, and the various IDS programs are discussed.

  11. Fat cells reactivate quiescent neuroblasts via TOR and glial insulin relays in Drosophila.

    PubMed

    Sousa-Nunes, Rita; Yee, Lih Ling; Gould, Alex P

    2011-03-24

    Many stem, progenitor and cancer cells undergo periods of mitotic quiescence from which they can be reactivated. The signals triggering entry into and exit from this reversible dormant state are not well understood. In the developing Drosophila central nervous system, multipotent self-renewing progenitors called neuroblasts undergo quiescence in a stereotypical spatiotemporal pattern. Entry into quiescence is regulated by Hox proteins and an internal neuroblast timer. Exit from quiescence (reactivation) is subject to a nutritional checkpoint requiring dietary amino acids. Organ co-cultures also implicate an unidentified signal from an adipose/hepatic-like tissue called the fat body. Here we provide in vivo evidence that Slimfast amino-acid sensing and Target of rapamycin (TOR) signalling activate a fat-body-derived signal (FDS) required for neuroblast reactivation. Downstream of this signal, Insulin-like receptor signalling and the Phosphatidylinositol 3-kinase (PI3K)/TOR network are required in neuroblasts for exit from quiescence. We demonstrate that nutritionally regulated glial cells provide the source of Insulin-like peptides (ILPs) relevant for timely neuroblast reactivation but not for overall larval growth. Conversely, ILPs secreted into the haemolymph by median neurosecretory cells systemically control organismal size but do not reactivate neuroblasts. Drosophila thus contains two segregated ILP pools, one regulating proliferation within the central nervous system and the other controlling tissue growth systemically. Our findings support a model in which amino acids trigger the cell cycle re-entry of neural progenitors via a fat-body-glia-neuroblasts relay. This mechanism indicates that dietary nutrients and remote organs, as well as local niches, are key regulators of transitions in stem-cell behaviour.

  12. 40 CFR 60.142 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973 § 60... primary oxygen blow. (ii) Exit from a control device not used solely for the collection of secondary.../dscm (0.030 gr/dscf), as measured for the primary oxygen blow. (ii) Exit from a control device not used...

  13. 40 CFR 60.142 - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973 § 60... primary oxygen blow. (ii) Exit from a control device not used solely for the collection of secondary.../dscm (0.030 gr/dscf), as measured for the primary oxygen blow. (ii) Exit from a control device not used...

  14. 40 CFR 60.142 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973 § 60... primary oxygen blow. (ii) Exit from a control device not used solely for the collection of secondary.../dscm (0.030 gr/dscf), as measured for the primary oxygen blow. (ii) Exit from a control device not used...

  15. 40 CFR 60.142 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973 § 60... primary oxygen blow. (ii) Exit from a control device not used solely for the collection of secondary.../dscm (0.030 gr/dscf), as measured for the primary oxygen blow. (ii) Exit from a control device not used...

  16. 40 CFR 60.142 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973 § 60... primary oxygen blow. (ii) Exit from a control device not used solely for the collection of secondary.../dscm (0.030 gr/dscf), as measured for the primary oxygen blow. (ii) Exit from a control device not used...

  17. Determining when a set of compute nodes participating in a barrier operation on a parallel computer are ready to exit the barrier operation

    DOEpatents

    Blocksome, Michael A [Rochester, MN

    2011-12-20

    Methods, apparatus, and products are disclosed for determining when a set of compute nodes participating in a barrier operation on a parallel computer are ready to exit the barrier operation that includes, for each compute node in the set: initializing a barrier counter with no counter underflow interrupt; configuring, upon entering the barrier operation, the barrier counter with a value in dependence upon a number of compute nodes in the set; broadcasting, by a DMA engine on the compute node to each of the other compute nodes upon entering the barrier operation, a barrier control packet; receiving, by the DMA engine from each of the other compute nodes, a barrier control packet; modifying, by the DMA engine, the value for the barrier counter in dependence upon each of the received barrier control packets; exiting the barrier operation if the value for the barrier counter matches the exit value.

  18. Development of EXITE3, Imaging Detectors and a Long Duration Balloon Gondola

    NASA Technical Reports Server (NTRS)

    2003-01-01

    In this Report we summarize the work conducted for the EXITE program under grant NAG5-5103. This grant supported the ongoing EXITE program at Harvard for the development of imaging hard x-ray detectors and telescopes over the 3 year period 1997-2000 with a one year extension to 2001 to transition to the next SR&T grant in this program. Work was conducted in three major parts: analysis of the EXITE2 balloon flight data (from our May 1997 flight); development of pixellated imaging Cd-Zn-Te detector arrays and readout systems for the proposed EXITE3 detector and telescope; and development of systems for a Long Duration Balloon (LDB) gondola. Progress on all three major aspects of this research is summarized for each of the years of this grant.

  19. 77 FR 153 - Passenger Train Emergency Systems II

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-03

    ... emergency exits and the path to the nearest exit in the dark. Existing signage inside some passenger... and markings in the dark. Debriefing and Critique FRA is proposing a modification to the existing... standard satisfactorily addresses matters related to emergency signage, exit path marking, and egress...

  20. ETR WASTE GAS EXITED THE ETR COMPLEX FROM THE NORTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR WASTE GAS EXITED THE ETR COMPLEX FROM THE NORTH SIDE THROUGH A TUNNEL AND THEN TO A FILTER PIT. TUNNEL EXIT IS UNDER CONSTRUCTION WHILE CONTROL BUILDING IS BEING FORMED BEYOND. CAMERA FACING WEST. INL NEGATIVE NO. 56-1238. Jack L. Anderson, Photographer, 4/17/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  1. Variable Sampling Mapping

    NASA Technical Reports Server (NTRS)

    Smith, Jeffrey, S.; Aronstein, David L.; Dean, Bruce H.; Lyon, Richard G.

    2012-01-01

    The performance of an optical system (for example, a telescope) is limited by the misalignments and manufacturing imperfections of the optical elements in the system. The impact of these misalignments and imperfections can be quantified by the phase variations imparted on light traveling through the system. Phase retrieval is a methodology for determining these variations. Phase retrieval uses images taken with the optical system and using a light source of known shape and characteristics. Unlike interferometric methods, which require an optical reference for comparison, and unlike Shack-Hartmann wavefront sensors that require special optical hardware at the optical system's exit pupil, phase retrieval is an in situ, image-based method for determining the phase variations of light at the system s exit pupil. Phase retrieval can be used both as an optical metrology tool (during fabrication of optical surfaces and assembly of optical systems) and as a sensor used in active, closed-loop control of an optical system, to optimize performance. One class of phase-retrieval algorithms is the iterative transform algorithm (ITA). ITAs estimate the phase variations by iteratively enforcing known constraints in the exit pupil and at the detector, determined from modeled or measured data. The Variable Sampling Mapping (VSM) technique is a new method for enforcing these constraints in ITAs. VSM is an open framework for addressing a wide range of issues that have previously been considered detrimental to high-accuracy phase retrieval, including undersampled images, broadband illumination, images taken at or near best focus, chromatic aberrations, jitter or vibration of the optical system or detector, and dead or noisy detector pixels. The VSM is a model-to-data mapping procedure. In VSM, fully sampled electric fields at multiple wavelengths are modeled inside the phase-retrieval algorithm, and then these fields are mapped to intensities on the light detector, using the properties of the detector and optical system, for comparison with measured data. Ultimately, this model-to-data mapping procedure enables a more robust and accurate way of incorporating the exit-pupil and image detector constraints, which are fundamental to the general class of ITA phase retrieval algorithms.

  2. Digital-computer normal shock position and restart control of a Mach 2.5 axisymmetric mixed-compression inlet

    NASA Technical Reports Server (NTRS)

    Neiner, G. H.; Cole, G. L.; Arpasi, D. J.

    1972-01-01

    Digital computer control of a mixed-compression inlet is discussed. The inlet was terminated with a choked orifice at the compressor face station to dynamically simulate a turbojet engine. Inlet diffuser exit airflow disturbances were used. A digital version of a previously tested analog control system was used for both normal shock and restart control. Digital computer algorithms were derived using z-transform and finite difference methods. Using a sample rate of 1000 samples per second, the digital normal shock and restart controls essentially duplicated the inlet analog computer control results. At a sample rate of 100 samples per second, the control system performed adequately but was less stable.

  3. Python Scripts for Automation of Current-Voltage Testing of Semiconductor Devices (FY17)

    DTIC Science & Technology

    2017-01-01

    ARL-TR-7923 ● JAN 2017 US Army Research Laboratory Python Scripts for Automation of Current- Voltage Testing of Semiconductor...manual device-testing procedures is reduced or eliminated through automation. This technical report includes scripts written in Python , version 2.7, used ...nothing. 3.1.9 Exit Program The script exits the entire program. Line 505, sys.exit(), uses the sys package that comes with Python to exit system

  4. Revisit the faster-is-slower effect for an exit at a corner

    NASA Astrophysics Data System (ADS)

    Chen, Jun Min; Lin, Peng; Wu, Fan Yu; Li Gao, Dong; Wang, Guo Yuan

    2018-02-01

    The faster-is-slower effect (FIS), which means that crowd at a high enough velocity could significantly increase the evacuation time to escape through an exit, is an interesting phenomenon in pedestrian dynamics. Such phenomenon had been studied widely and has been experimentally verified in different systems of discrete particles flowing through a centre exit. To experimentally validate this phenomenon by using people under high pressure is difficult due to ethical issues. A mouse, similar to a human, is a kind of self-driven and soft body creature with competitive behaviour under stressed conditions. Therefore, mice are used to escape through an exit at a corner. A number of repeated tests are conducted and the average escape time per mouse at different levels of stimulus are analysed. The escape times do not increase obviously with the level of stimulus for the corner exit, which is contrary to the experiment with the center exit. The experimental results show that the FIS effect is not necessary a universal law for any discrete system. The observation could help the design of buildings by relocating their exits to the corner in rooms to avoid the formation of FIS effect.

  5. Design of ocular for optical sight with long exit pupil distance

    NASA Astrophysics Data System (ADS)

    Zhu, Zhongyao; Li, Yuyao; Tian, Ailing

    2017-02-01

    In order to solve the injury of optical sight to shooters, which is produced by recoil for using artillery or firearms, and the usage problems of shooters' eye mask, headband and gas mask, the ocular with long exit pupil distance has been designed based on optical sighting system. The optical properties and aberration characteristics of ocular with long exit pupil distance has been analyzed, the structural style with positive-positive-negative three lens groups has been put forward. According to the aberration theory and the isoplanatic image formation principle, the focal power assignment expression has been deduced by adopting analytical method. By using of optical design software ZEMAX, the ocular with long exit pupil distance has been designed, the focal length of system is 20mm, the exit pupil diameter is 4mm, the field angle is 40°, the distance of exit pupil is 41mm, and the relative eye relief is greater than 2. The design results show if this method has been adopted, the transfer functions of each field are all greater than 0.15 when the ocular with long exit pupil distance locates on 45lp/mm, which can meet the use requirements of visual optical instruments.

  6. In situ calibration of a light source in a sensor device

    DOEpatents

    Okandan, Murat; Serkland, Darwin k.; Merchant, Bion J.

    2015-12-29

    A sensor device is described herein, wherein the sensor device includes an optical measurement system, such as an interferometer. The sensor device further includes a low-power light source that is configured to emit an optical signal having a constant wavelength, wherein accuracy of a measurement output by the sensor device is dependent upon the optical signal having the constant wavelength. At least a portion of the optical signal is directed to a vapor cell, the vapor cell including an atomic species that absorbs light having the constant wavelength. A photodetector captures light that exits the vapor cell, and generates an electrical signal that is indicative of intensity of the light that exits the vapor cell. A control circuit controls operation of the light source based upon the electrical signal, such that the light source emits the optical signal with the constant wavelength.

  7. Preliminary Design of Critical Function Monitoring System of PGSFR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-07-01

    A PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor) is under development at Korea Atomic Energy Research Institute. A critical function monitoring system of the PGSFR is preliminarily studied. The functions of CFMS are to display critical plant variables related to the safety of the plant during normal and accident conditions and guide the operators corrective actions to keep the plant in a safe condition and mitigate the consequences of accidents. The minimal critical functions of the PGSFR are composed of reactivity control, reactor core cooling, reactor coolant system integrity, primary heat transfer system(PHTS) heat removal, sodium water reaction mitigation, radiation controlmore » and containment conditions. The variables and alarm legs of each critical function of the PGSFR are as follows; - Reactivity control: The variables of reactivity control function are power range neutron flux instrumentation, intermediate range neutron flux instrumentation, source range neutron flux instrumentation, and control rod bottom contacts. The alarm leg to display the reactivity controls consists of status of control drop malfunction, high post trip power and thermal reactivity addition. - Reactor core cooling: The variables are PHTS sodium level, hot pool temperature of PHTS, subassembly exit temperature, cold pool temperature of the PHTS, PHTS pump current, and PHTS pump breaker status. The alarm leg consists of high core delta temperature, low sodium level of the PHTS, high subassembly exit temperature, and low PHTS pump load. - Reactor coolant system integrity: The variables are PHTS sodium level, cover gas pressure, and safeguard vessel sodium level. The alarm leg is composed of low sodium level of PHTS, high cover gas pressure and high sodium level of the safety guard vessel. - PHTS heat removal: The variables are PHTS sodium level, hot pool temperature of PHTS, core exit temperature, cold pool temperature of the PHTS, flow rate of passive residual heat removal system, flow rate of active residual heat removal system, and temperatures of air heat exchanger temperature of residual heat removal systems. The alarm legs are composed of two legs of a 'passive residual heat removal system not cooling' and 'active residual heat removal system not cooling'. - Sodium water reaction mitigation: The variables are intermediate heat transfer system(IHTS) pressure, pressure and temperature and level of sodium dump tank, the status of rupture disk, hydrogen concentration in IHTS and direct variable of sodium-water-reaction measure. The alarm leg consists of high IHTS pressure, the status of sodium water reaction mitigation system and the indication of direct measure. - Radiation control: The variables are radiation of PHTS, radiation of IHTS, and radiation of containment purge. The alarm leg is composed of high radiation of PHTS and IHTS, and containment purge system. - Containment condition: The variables are containment pressure, containment isolation status, and sodium fire. The alarm leg consists of high containment pressure, status of containment isolation and status of sodium fire. (authors)« less

  8. Wavefront control of large optical systems

    NASA Technical Reports Server (NTRS)

    Meinel, Aden B.; Meinel, Marjorie P.; Breckinridge, J. B.

    1990-01-01

    Several levels of wavefront control are necessary for the optimum performance of very large telescopes, especially segmented ones like the Large Deployable Reflector. In general, the major contributors to wavefront error are the segments of the large primary mirror. Wavefront control at the largest optical surface may not be the optimum choice because of the mass and inaccessibility of the elements of this surface that require upgrading. The concept of two-stage optics was developed to permit a poor wavefront from the large optics to be upgraded by means of a wavefront corrector at a small exit pupil of the system.

  9. Control of the mitotic exit network during meiosis

    PubMed Central

    Attner, Michelle A.; Amon, Angelika

    2012-01-01

    The mitotic exit network (MEN) is an essential GTPase signaling pathway that triggers exit from mitosis in budding yeast. We show here that during meiosis, the MEN is dispensable for exit from meiosis I but contributes to the timely exit from meiosis II. Consistent with a role for the MEN during meiosis II, we find that the signaling pathway is active only during meiosis II. Our analysis further shows that MEN signaling is modulated during meiosis in several key ways. Whereas binding of MEN components to spindle pole bodies (SPBs) is necessary for MEN signaling during mitosis, during meiosis MEN signaling occurs off SPBs and does not require the SPB recruitment factor Nud1. Furthermore, unlike during mitosis, MEN signaling is controlled through the regulated interaction between the MEN kinase Dbf20 and its activating subunit Mob1. Our data lead to the conclusion that a pathway essential for vegetative growth is largely dispensable for the specialized meiotic divisions and provide insights into how cell cycle regulatory pathways are modulated to accommodate different modes of cell division. PMID:22718910

  10. Formation of vortex pairs with hinged rigid flaps at the nozzle exit

    NASA Astrophysics Data System (ADS)

    Das, Prashant; Govardhan, Raghuraman; Arakeri, Jaywant

    2013-11-01

    Biological flows related to aquatic propulsion using pulsed jets, or flow through the valves in a human heart, have received considerable attention in the last two decades. Both these flows are associated with starting jets that occur through biological tissue/membranes that are flexible. Motivated by these flows, we explore in the present work, the effect of passive flexibility of the nozzle exit on vortex generation from a starting jet. The starting jet is generated using a two-dimensional piston cylinder mechanism, the cross-section of the cylinder being rectangular with large aspect ratio. The fluid is pushed out of this cylinder or channel using a computer controlled piston. We introduce flexibility at the channel exit by hinging rigid flaps, which are initially parallel to the channel. The hinge used is such that it provides negligible stiffness or damping, thus allowing for the maximum opening of the flaps due to fluid forces. Using this system, we study both the flap kinematics and the vorticity dynamics downstream of the channel exit. Visualizations show large flap motions as the piston starts and this dramatically changes the vorticity distribution downstream of the flaps, with the formation of up to three different kinds of vortex pairs. This idealized configuration opens new opportunities to look at the effect of flexibility in such biological flows.

  11. Laboratory evaluation of the irritancy of bendiocarb, lambda-cyhalothrin and DDT to Anopheles gambiae.

    PubMed

    Evans, R G

    1993-09-01

    In a laboratory study, the irritancy of bendiocarb, lambda-cyhalothrin and DDT to Anopheles gambiae was evaluated at field, 1/3 field and 1/10 field rates using WHO conical exposure chambers and excito-repellency test boxes. Bendiocarb was the least irritant insecticide at all rates, inducing levels of takeoff, flight and exiting behavior similar to those of a distilled water control treatment. Of those mosquitoes introduced to the bendiocarb-treated boxes, not more than 1% exited and survived at any dose rate. Lambda-cyhalothrin and DDT were highly irritant to An. gambiae, inducing a strong stimulation to take off and fly and also a high level of exiting. Exiting-survival rates associated with lambda-cyhalothrin and DDT were between 15 and 51%. The relevance of these findings to the control of mosquito populations and the prevention of malaria transmission is discussed.

  12. Laser Doppler systems in pollution monitoring

    NASA Technical Reports Server (NTRS)

    Miller, C. R.; Sonnenschein, C. M.; Herget, W. F.; Huffaker, R. M.

    1976-01-01

    The paper reports on a program undertaken to determine the feasibility of using a laser Doppler velocimeter (LDV) to measure smoke-stack gas exit velocity, particulate concentration, and mass flow. Measurements made with a CO2 laser Doppler radar system at a coal-burning power plant are compared with in-stack measurements made by a pitot tube. The operational principles of a LDV are briefly described along with the system employed in the present study. Data discussed include typical Doppler spectra from smoke-stack effluents at various laser elevation angles, the measured velocity profile across the stack exit, and the LDV-measured exit velocity as a function of the exit velocity measured by the in-stack instrument. The in-stack velocity is found to be about 14% higher than the LDV velocity, but this discrepancy is regarded as a systematic error. In general, linear relationships are observed between the laser data, the exit velocity, and the particulate concentration. It is concluded that an LDV has the capability of determining both the mass concentration and the mass flow from a power-plant smoke stack.

  13. 14 CFR Appendix B to Part 187 - Fees for FAA Services for Certain Flights

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....-controlled airspace.) Distance flown is based on the great circle distance (GCD) for the point of entry and the point of exit of U.S.-controlled airspace based on FAA flight data. Fees are assessed using the methodology presented in paragraph (e)(2) of this appendix. Where actual entry and exit points are not...

  14. The Effect of Exit-Site Antibacterial Honey Versus Nasal Mupirocin Prophylaxis on the Microbiology and Outcomes of Peritoneal Dialysis-Associated Peritonitis and Exit-Site Infections: A Sub-Study of the Honeypot Trial.

    PubMed

    Zhang, Lei; Badve, Sunil V; Pascoe, Elaine M; Beller, Elaine; Cass, Alan; Clark, Carolyn; de Zoysa, Janak; Isbel, Nicole M; McTaggart, Steven; Morrish, Alicia T; Playford, E Geoffrey; Scaria, Anish; Snelling, Paul; Vergara, Liza A; Hawley, Carmel M; Johnson, David W

    2015-12-01

    ♦ The HONEYPOT study recently reported that daily exit-site application of antibacterial honey was not superior to nasal mupirocin prophylaxis for preventing overall peritoneal dialysis (PD)-related infection. This paper reports a secondary outcome analysis of the HONEYPOT study with respect to exit-site infection (ESI) and peritonitis microbiology, infectious hospitalization and technique failure. ♦ A total of 371 PD patients were randomized to daily exit-site application of antibacterial honey plus usual exit-site care (N = 186) or intranasal mupirocin prophylaxis (in nasal Staphylococcus aureus carriers only) plus usual exit-site care (control, N = 185). Groups were compared on rates of organism-specific ESI and peritonitis, peritonitis- and infection-associated hospitalization, and technique failure (PD withdrawal). ♦ The mean peritonitis rates in the honey and control groups were 0.41 (95% confidence interval [CI] 0.32 - 0.50) and 0.41 (95% CI 0.33 - 0.49) episodes per patient-year, respectively (incidence rate ratio [IRR] 1.01, 95% CI 0.75 - 1.35). When specific causative organisms were examined, no differences were observed between the groups for gram-positive (IRR 0.99, 95% CI 0.66 - 1.49), gram-negative (IRR 0.71, 95% CI 0.39 - 1.29), culture-negative (IRR 2.01, 95% CI 0.91 - 4.42), or polymicrobial peritonitis (IRR 1.08, 95% CI 0.36 - 3.20). Exit-site infection rates were 0.37 (95% CI 0.28 - 0.45) and 0.33 (95% CI 0.26 - 0.40) episodes per patient-year for the honey and control groups, respectively (IRR 1.12, 95% CI 0.81 - 1.53). No significant differences were observed between the groups for gram-positive (IRR 1.10, 95% CI 0.70 - 1.72), gram-negative (IRR: 0.85, 95% CI 0.46 - 1.58), culture-negative (IRR 1.88, 95% CI 0.67 - 5.29), or polymicrobial ESI (IRR 1.00, 95% CI 0.40 - 2.54). Times to first peritonitis-associated and first infection-associated hospitalization were similar in the honey and control groups. The rates of technique failure (PD withdrawal) due to PD-related infection were not significantly different between the groups. ♦ Compared with standard nasal mupirocin prophylaxis, daily topical exit-site application of antibacterial honey resulted in comparable rates of organism-specific peritonitis and ESI, infection-associated hospitalization, and infection-associated technique failure in PD patients. Copyright © 2015 International Society for Peritoneal Dialysis.

  15. 30 CFR 56.4530 - Exits.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... a sufficient number of exits to permit prompt escape in case of fire. ...

  16. View looking out of the Irving Powerhouse showing the exiting ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View looking out of the Irving Powerhouse showing the exiting water flowing south into the inlet of the Childs System. Looking south - Childs-Irving Hydroelectric Project, Irving System, Irving Powerhouse, Forest Service Road 708/502, Camp Verde, Yavapai County, AZ

  17. A PP2A-B55 recognition signal controls substrate dephosphorylation kinetics during mitotic exit

    PubMed Central

    Cundell, Michael J.; Holder, James

    2016-01-01

    PP2A-B55 is one of the major phosphatases regulating cell division. Despite its importance for temporal control during mitotic exit, how B55 substrates are recognized and differentially dephosphorylated is unclear. Using phosphoproteomics combined with kinetic modeling to extract B55-dependent rate constants, we have systematically identified B55 substrates and assigned their temporal order in mitotic exit. These substrates share a bipartite polybasic recognition determinant (BPR) flanking a Cdk1 phosphorylation site. Experiments and modeling show that dephosphorylation rate is encoded into B55 substrates, including its inhibitor ENSA, by cooperative action of basic residues within the BPR. A complementary acidic surface on B55 decodes this signal, supporting a cooperative electrostatic mechanism for substrate selection. A further level of specificity is encoded into B55 substrates because B55 displays selectivity for phosphothreonine. These simple biochemical properties, combined with feedback control of B55 activity by the phosphoserine-containing substrate/inhibitor ENSA, can help explain the temporal sequence of events during exit from mitosis. PMID:27551054

  18. Comparison of topical mupirocin and gentamicin in the prevention of peritoneal dialysis-related infections: A systematic review and meta-analysis.

    PubMed

    Tsai, Chia-Chi; Yang, Po-Sheng; Liu, Chien-Liang; Wu, Chih-Jen; Hsu, Yi-Chiung; Cheng, Shih-Ping

    2018-01-01

    Topical antibiotics have been shown to reduce exit-site infection and peritonitis. The aim of this study was to compare infection rates between mupirocin and gentamicin. Multiple comprehensive databases were searched systematically to include relevant randomized controlled trials and observational studies. Pooled risk ratios (RRs) and 95% confidence intervals were calculated for the incidences of exit-site infection and peritonitis. Seven studies (mupirocin group n = 458, gentamicin group n = 448) were analyzed for exit-site infection. The risk of gram-positive exit-site infection was similar between the groups. Gram-negative exit-site infection rate was higher in the mupirocin group (RR = 2.125, P = 0.037). Six studies were assessed the peritonitis risk. There was no difference in the gram-positive and -negative peritonitis rate. Topical use of gentamicin is associated with fewer exit-site infections caused by gram-negative organisms. Gentamicin has comparable efficacy to mupirocin for peritonitis and gram-positive exit-site infection. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. TF34 convertible engine control system design

    NASA Technical Reports Server (NTRS)

    Gilmore, D. R., Jr.

    1984-01-01

    The characteristics of the TF34 convertible engine, capable of producing shaft power, thrust, or a combination of both, is investigated with respect to the control system design, development, bench testing, and the anticipated transient response during engine testing at NASA. The modifications to the prototype standard TF34-GE-400 turbofan, made primarily in the fan section, consist of the variable inlet guide vanes and variable exit guide vanes. The control system was designed using classical frequency domain techniques and was based on the anticipated convertible/VTOL airframe requirements. The engine has been run in the fan mode and in the shaft mode, exhibiting a response of 0.14 second to a 5-percent thrust change.

  20. Transition duct system with arcuate ceramic liner for delivering hot-temperature gases in a combustion turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiebe, David J.

    A transition duct system (10) for delivering hot-temperature gases from a plurality of combustors in a combustion turbine engine is provided. The system includes an exit piece (16) for each combustor. The exit piece may include an arcuate connecting segment (36). An arcuate ceramic liner (60) may be inwardly disposed onto a metal outer shell (38) along the arcuate connecting segment of the exit piece. Structural arrangements are provided to securely attach the ceramic liner in the presence of substantial flow path pressurization. Cost-effective serviceability of the transition duct systems is realizable since the liner can be readily removed andmore » replaced as needed.« less

  1. Effects of temperament and acclimation to handling on feedlot performance of Bos taurus feeder cattle originated from a rangeland-based cow-calf system.

    PubMed

    Francisco, C L; Cooke, R F; Marques, R S; Mills, R R; Bohnert, D W

    2012-12-01

    Two experiments evaluated the effects of temperament and acclimation to handling on performance of Angus × Hereford feeder cattle reared in extensive rangeland systems until weaning. In Exp. 1, 200 calves (n = 97 for yr 1; n = 103 for yr 2) were evaluated for temperament at weaning (average age ± SE = 152 ± 1 d) by chute score and exit velocity. Chute score was assessed on a 5-point scale according to behavior during chute restraining. Exit score was calculated by dividing exit velocity into quintiles and assigning calves a score from 1 (slowest) to 5 (fastest). A temperament score was calculated for each calf by averaging chute and exit scores. Calf temperament was classified according to temperament score as adequate (≤3) or excitable (>3). After weaning, calves were assigned to a 40-d preconditioning followed by growing (139 d) and finishing (117 d) phases until slaughter. Weaning BW was decreased (P = 0.04) in excitable calves compared with adequate calves. No differences were detected (P ≥ 0.21) for ADG during preconditioning, growing, and finishing phases; hence, excitable calves tended (P = 0.09) to have decreased HCW compared with adequate calves. In Exp. 2, 60 steers (initial age ± SE = 198 ± 2 d) were weighed and evaluated for temperament score 35 d after weaning (d -29). On d -28, steers were ranked by these variables and assigned to receive an acclimation treatment or not (control). Acclimated steers were processed through a handling facility twice weekly for 4 wk (d -28 to -1) whereas control steers remained undisturbed on pasture. On d 0, all steers were transported for 24 h and returned to the research facility (d 1). On arrival, steers were ranked by BW within treatment and randomly assigned to 20 feedlot pens for a 28-d feedlot receiving period. Acclimated steers had decreased temperament score and plasma cortisol compared with controls on d 0 (P = 0.02). During feedlot receiving, acclimated steers had decreased ADG (P < 0.01) and G:F (P = 0.03) and tended to have decreased DMI (P = 0.07) compared with controls. Acclimated steers had greater plasma haptoglobin on d 4 (P = 0.04) and greater ceruloplasmin from d 0 to 10 (P ≤ 0.04) and tended to have greater cortisol on d 1 (P = 0.08) than controls. In conclusion, temperament affects productivity of beef operations based on Bos taurus feeder cattle reared in extensive rangeland systems until weaning whereas acclimation to handling ameliorated cattle temperament but did not benefit feedlot receiving performance.

  2. Experimental Assessment of the Emissions Control Potential of a Rich/Quench/Lean Combustor for High Speed Civil Transport Aircraft Engines

    NASA Technical Reports Server (NTRS)

    Rosfjord, T. J.; Padget, F. C.; Tacina, Robert R. (Technical Monitor)

    2001-01-01

    In support of Pratt & Whitney efforts to define the Rich burn/Quick mix/Lean burn (RQL) combustor for the High Speed Civil Transport (HSCT) aircraft engine, UTRC conducted a flametube-scale study of the RQL concept. Extensive combustor testing was performed at the Supersonic Cruise (SSC) condition of a HSCT engine cycle, Data obtained from probe traverses near the exit of the mixing section confirmed that the mixing section was the critical component in controlling combustor emissions. Circular-hole configurations, which produced rapidly-, highly-penetrating jets, were most effective in limiting NOx. The spatial profiles of NOx and CO at the mixer exit were not directly interpretable using a simple flow model based on jet penetration, and a greater understanding of the flow and chemical processes in this section are required to optimize it. Neither the rich-combustor equivalence ratio nor its residence time was a direct contributor to the exit NOx. Based on this study, it was also concluded that (1) While NOx formation in both the mixing section and the lean combustor contribute to the overall emission, the NOx formation in the mixing section dominates. The gas composition exiting the rich combustor can be reasonably represented by the equilibrium composition corresponding to the rich combustor operating condition. Negligible NOx exits the rich combustor. (2) At the SSC condition, the oxidation processes occurring in the mixing section consume 99 percent of the CO exiting the rich combustor. Soot formed in the rich combustor is also highly oxidized, with combustor exit SAE Smoke Number <3. (3) Mixing section configurations which demonstrated enhanced emissions control at SSC also performed better at part-power conditions. Data from mixer exit traverses reflected the expected mixing behavior for off-design jet to crossflow momentum-flux ratios. (4) Low power operating conditions require that the RQL combustor operate as a lean-lean combustor to achieve low CO and high efficiency. (5) A RQL combustor can achieve the emissions goal of EINOX = 5 at the Supersonic Cruise operating condition for a HSCT engine.

  3. Experimental Assessment of the Emissions Control Potential of a Rich/Quench/ Lean Combustor for High Speed Civil Transport Aircraft Engines

    NASA Technical Reports Server (NTRS)

    Tacina, Robert R. (Technical Monitor); Rosfjord, T. J.; Padget, F. C.

    2001-01-01

    In support of Pratt & Whitney efforts to define the Rich burn/Quick mix/Lean burn (RQL) combustor for the High Speed Civil Transport (HSCT) aircraft engine, UTRC conducted a flametube-scale study of the RQL concept. Extensive combustor testing was performed at the Supersonic Cruise (SSC) condition of an HSCT engine cycle. Data obtained from probe traverses near the exit of the mixing section confirmed that the mixing section was the critical component in controlling combustor emissions. Circular-hole configurations, which produced rapidly-, highly-penetrating jets, were most effective in limiting NO(x). The spatial profiles of NO(x) and CO at the mixer exit were not directly interpretable using a simple flow model based on jet penetration, and a greater understanding of the flow and chemical processes in this section are required to optimize it. Neither the rich-combustor equivalence ratio nor its residence time was a direct contributor to the exit NO(x). Based on this study, it was also concluded that: (1) While NO(x) formation in both the mixing section and the lean combustor contribute to the overall emission, the NOx formation in the mixing section dominates. The gas composition exiting the rich combustor can be reasonably represented by the equilibrium composition corresponding to the rich combustor operating condition. Negligible NO(x) exits the rich combustor. (2) At the SSC condition, the oxidation processes occurring in the mixing section consume 99 percent of the CO exiting the rich combustor. Soot formed in the rich combustor is also highly oxidized, with combustor exit SAE Smoke Number <3. (3) Mixing section configurations which demonstrated enhanced emissions control at SSC also performed better at part-power conditions. Data from mixer exit traverses reflected the expected mixing behavior for off-design jet to crossflow momentum-flux ratios. (4) Low power operating conditions require that the RQL combustor operate as a lean-lean combustor to achieve low CO and high efficiency. (5) An RQL combustor can achieve the emissions goal of EINO(x) = 5 at the Supersonic Cruise operating condition for an HSCT engine.

  4. School Gardening with a Twist Using Fish: Encouraging Educators to Adopt Aquaponics in the Classroom

    ERIC Educational Resources Information Center

    Clayborn, Jaeson; Medina, Miles; O'Brien, George

    2017-01-01

    To evaluate the willingness of teachers to incorporate aquaponics in the classroom, we engaged teachers in a 6-week project. Participants in the experimental group maintained small-scale aquaponic systems. All teachers completed pretests and posttests, and exit surveys. Both groups (experimental and control) scored significantly higher on the…

  5. Method for Making Measurements of the Post-Combustion Residence Time in a Gas Turbine Engine

    NASA Technical Reports Server (NTRS)

    Miles, Jeffrey H (Inventor)

    2015-01-01

    A system and method of measuring a residence time in a gas-turbine engine is provided, whereby the method includes placing pressure sensors at a combustor entrance and at a turbine exit of the gas-turbine engine and measuring a combustor pressure at the combustor entrance and a turbine exit pressure at the turbine exit. The method further includes computing cross-spectrum functions between a combustor pressure sensor signal from the measured combustor pressure and a turbine exit pressure sensor signal from the measured turbine exit pressure, applying a linear curve fit to the cross-spectrum functions, and computing a post-combustion residence time from the linear curve fit.

  6. Reduction of exit-site infections of tunnelled intravascular catheters among neutropenic patients by sustained-release chlorhexidine dressings: results from a prospective randomized controlled trial.

    PubMed

    Chambers, S T; Sanders, J; Patton, W N; Ganly, P; Birch, M; Crump, J A; Spearing, R L

    2005-09-01

    Exit-site and tunnel infections of tunnelled central intravascular catheters are a frequent source of morbidity among neutropenic patients and may necessitate catheter removal. They require antimicrobial therapy that increases healthcare costs and is associated with adverse drug reactions. A prospective randomized clinical trial was conducted among adult patients undergoing chemotherapy in a haematology unit. Tunnelled intravascular catheters were randomized to receive the control of a standard dressing regimen as recommended by the British Committee for Standards in Haematology, or to receive the intervention of a sustained-release chlorhexidine dressing. Follow-up data were available in 112 of 114 tunnelled intravascular catheters which were randomized. Exit-site or combined exit-site/tunnel infections occurred in 23 (43%) of 54 catheters in the control group, and five (9%) of 58 catheters in the intervention group [odds ratio (OR) for intervention group compared with control group =0.13, 95% confidence intervals (CI) 0.04-0.37, P<0.001]. More tunnelled intravascular catheters were prematurely removed from the control group than the intervention group for documented infections [20/54 (37%) vs 6/58 (10%), OR=0.20, 95%CI 0.53-0.07]. However, there was no difference in the numbers of tunnelled intravascular catheters removed for all proven and suspected intravascular catheter-related infections [21/54 (39%) vs 19/58 (33%)], or in the time to removal of catheters for any reason other than death or end of treatment for underlying disease. Thus chlorhexidine dressings reduced the incidence of exit-site/tunnel infections of indwelling tunnelled intravascular catheters without prolonging catheter survival in neutropenic patients, and could be considered as part of the routine management of indwelling tunnelled intravascular catheters among neutropenic patients.

  7. Experimental investigation of the 2D ion beam profile generated by an ESI octopole-QMS system.

    PubMed

    Syed, Sarfaraz U A H; Eijkel, Gert B; Kistemaker, Piet; Ellis, Shane; Maher, Simon; Smith, Donald F; Heeren, Ron M A

    2014-10-01

    In this paper, we have employed an ion imaging approach to investigate the behavior of ions exiting from a quadrupole mass spectrometer (QMS) system that employs a radio frequency octopole ion guide before the QMS. An in-vacuum active pixel detector (Timepix) is employed at the exit of the QMS to image the ion patterns. The detector assembly simultaneously records the ion impact position and number of ions per pixel in every measurement frame. The transmission characteristics of the ion beam exiting the QMS are studied using this imaging detector under different operating conditions. Experimental results confirm that the ion spatial distribution exiting the QMS is heavily influenced by ion injection conditions. Furthermore, ion images from Timepix measurements of protein standards demonstrate the capability to enhance the quality of the mass spectral information and provide a detailed insight in the spatial distribution of different charge states (and hence different m/z) ions exiting the QMS.

  8. Telescope Multi-Field Wavefront Control with a Kalman Filter

    NASA Technical Reports Server (NTRS)

    Lou, John Z.; Redding, David; Sigrist, Norbert; Basinger, Scott

    2008-01-01

    An effective multi-field wavefront control (WFC) approach is demonstrated for an actuated, segmented space telescope using wavefront measurements at the exit pupil, and the optical and computational implications of this approach are discussed. The integration of a Kalman Filter as an optical state estimator into the wavefront control process to further improve the robustness of the optical alignment of the telescope will also be discussed. Through a comparison of WFC performances between on-orbit and ground-test optical system configurations, the connection (and a possible disconnection) between WFC and optical system alignment under these circumstances are analyzed. Our MACOS-based computer simulation results will be presented and discussed.

  9. Development of an Energetic X-Ray Imaging Telescope Experiment (EXITE) and Associated Balloon Gondola System

    NASA Technical Reports Server (NTRS)

    1997-01-01

    This is the Final Report for grant NAGW-624, which was our original grant to develop the Energetic X- ray Imaging Telescope Experiment (EXITE) and Associated Balloon Gondola. The EXITE grant was changed over to a new grant (from GSFC), NAG5-5103, beginning in FY97 and is currently very much continuing under that grant. The Final Report presented here then covers the EXITE development under the original grant, which in fact continued (with a 1 year no-cost extension) through December 31, 1997.

  10. Conversion to eslicarbazepine acetate monotherapy

    PubMed Central

    French, Jacqueline; Jacobson, Mercedes P.; Pazdera, Ladislav; Gough, Mallory; Cheng, Hailong; Grinnell, Todd; Blum, David

    2016-01-01

    Objective: To assess the efficacy and safety of eslicarbazepine acetate (ESL) monotherapy. Methods: This post hoc pooled analysis of 2 randomized double-blind studies (093-045 and -046) included adults with partial-onset seizures medically uncontrolled by 1 or 2 antiepileptic drugs (AEDs). Following the baseline period (8 weeks), eligible patients were randomized 2:1 to receive ESL 1,600 mg or 1,200 mg once daily for 18 weeks; the primary endpoint was study exit by meeting predefined exit criteria (signifying worsening seizure control). In each study, treatment was considered effective if the upper 95% confidence limit for exit rate was lower than the historical control threshold (65.3%). Results: Pooled exit rates were as follows: ESL 1,600 mg = 20.6% (95% confidence interval: 15.6%–26.8%); ESL 1,200 mg = 30.8% (23.0%–40.5%). Use of 2 baseline AEDs or rescue medication, US location, epilepsy duration ≥20 years, and higher maximum baseline seizure frequency were associated with higher exit risks. Median percent reductions in standardized seizure frequency between baseline and the 18-week double-blind period were as follows: ESL 1,600 mg = 43.2%; ESL 1,200 mg = 35.7%; baseline carbamazepine use was associated with smaller reductions. Safety profiles were similar between ESL doses. Conclusions: Exit rates for ESL monotherapy (1,600 mg and 1,200 mg once daily) were lower than the historical control threshold, irrespective of baseline AED use and region, with no additional safety concerns identified. Clinical factors and location clearly influence treatment responses in conversion-to-monotherapy trials. Classification of evidence: This pooled analysis provides Class IV evidence that for adults with medically uncontrolled partial-onset seizures, ESL monotherapy is well tolerated and effective. PMID:26911639

  11. Conversion to eslicarbazepine acetate monotherapy: A pooled analysis of 2 phase III studies.

    PubMed

    Sperling, Michael R; French, Jacqueline; Jacobson, Mercedes P; Pazdera, Ladislav; Gough, Mallory; Cheng, Hailong; Grinnell, Todd; Blum, David

    2016-03-22

    To assess the efficacy and safety of eslicarbazepine acetate (ESL) monotherapy. This post hoc pooled analysis of 2 randomized double-blind studies (093-045 and -046) included adults with partial-onset seizures medically uncontrolled by 1 or 2 antiepileptic drugs (AEDs). Following the baseline period (8 weeks), eligible patients were randomized 2:1 to receive ESL 1,600 mg or 1,200 mg once daily for 18 weeks; the primary endpoint was study exit by meeting predefined exit criteria (signifying worsening seizure control). In each study, treatment was considered effective if the upper 95% confidence limit for exit rate was lower than the historical control threshold (65.3%). Pooled exit rates were as follows: ESL 1,600 mg = 20.6% (95% confidence interval: 15.6%-26.8%); ESL 1,200 mg = 30.8% (23.0%-40.5%). Use of 2 baseline AEDs or rescue medication, US location, epilepsy duration ≥20 years, and higher maximum baseline seizure frequency were associated with higher exit risks. Median percent reductions in standardized seizure frequency between baseline and the 18-week double-blind period were as follows: ESL 1,600 mg = 43.2%; ESL 1,200 mg = 35.7%; baseline carbamazepine use was associated with smaller reductions. Safety profiles were similar between ESL doses. Exit rates for ESL monotherapy (1,600 mg and 1,200 mg once daily) were lower than the historical control threshold, irrespective of baseline AED use and region, with no additional safety concerns identified. Clinical factors and location clearly influence treatment responses in conversion-to-monotherapy trials. This pooled analysis provides Class IV evidence that for adults with medically uncontrolled partial-onset seizures, ESL monotherapy is well tolerated and effective. © 2016 American Academy of Neurology.

  12. Terminal shock position and restart control of a Mach 2.7, two-dimensional, twin duct mixed compression inlet

    NASA Technical Reports Server (NTRS)

    Cole, G. L.; Neiner, G. H.; Baumbick, R. J.

    1973-01-01

    Experimental results of terminal shock and restart control system tests of a two-dimensional, twin-duct mixed compression inlet are presented. High-response (110-Hz bandwidth) overboard bypass doors were used, both as the variable to control shock position and as the means of disturbing the inlet airflow. An inherent instability in inlet shock position resulted in noisy feedback signals and thus restricted the terminal shock position control performance that was achieved. Proportional-plus-integral type controllers using either throat exit static pressure or shock position sensor feedback gave adequate low-frequency control. The inlet restart control system kept the terminal shock control loop closed throughout the unstart-restart transient. The capability to restart the inlet was non limited by the inlet instability.

  13. Development of an Actuator for Flow Control Utilizing Detonation

    NASA Technical Reports Server (NTRS)

    Lonneman, Patrick J.; Cutler, Andrew D.

    2004-01-01

    Active flow control devices including mass injection systems and zero-net-mass flux actuators (synthetic jets) have been employed to delay flow separation. These devices are capable of interacting with low-speed, subsonic flows, but situations exist where a stronger crossflow interaction is needed. Small actuators that utilize detonation of premixed fuel and oxidizer should be capable of producing supersonic exit jet velocities. An actuator producing exit velocities of this magnitude should provide a more significant interaction with transonic and supersonic crossflows. This concept would be applicable to airfoils on high-speed aircraft as well as inlet and diffuser flow control. The present work consists of the development of a detonation actuator capable of producing a detonation in a single shot (one cycle). Multiple actuator configurations, initial fill pressures, oxidizers, equivalence ratios, ignition energies, and the addition of a turbulence generating device were considered experimentally and computationally. It was found that increased initial fill pressures and the addition of a turbulence generator aided in the detonation process. The actuators successfully produced Chapman-Jouguet detonations and wave speeds on the order of 3000 m/s.

  14. Two inhibitory systems and CKIs regulate cell cycle exit of mammalian cardiomyocytes after birth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tane, Shoji; Okayama, Hitomi; Ikenishi, Aiko

    Mammalian cardiomyocytes actively proliferate during embryonic stages, following which they exit their cell cycle after birth, and the exit is maintained. Previously, we showed that two inhibitory systems (the G1-phase inhibitory system: repression of cyclin D1 expression; the M-phase inhibitory system: inhibition of CDK1 activation) maintain the cell cycle exit of mouse adult cardiomyocytes. We also showed that two CDK inhibitors (CKIs), p21{sup Cip1} and p27{sup Kip1}, regulate the cell cycle exit in a portion of postnatal cardiomyocytes. It remains unknown whether the two inhibitory systems are involved in the cell cycle exit of postnatal cardiomyocytes and whether p21{sup Cip1}more » and p27{sup Kip1} also inhibit entry to M-phase. Here, we showed that more than 40% of cardiomyocytes entered an additional cell cycle by induction of cyclin D1 expression at postnatal stages, but M-phase entry was inhibited in the majority of cardiomyocytes. Marked cell cycle progression and endoreplication were observed in cardiomyocytes of p21{sup Cip1} knockout mice at 4 weeks of age. In addition, tri- and tetranucleated cardiomyocytes increased significantly in p21{sup Cip1} knockout mice. These data showed that the G1-phase inhibitory system and two CKIs (p21{sup Cip1} and p27{sup Kip1}) inhibit entry to an additional cell cycle in postnatal cardiomyocytes, and that the M-phase inhibitory system and p21{sup Cip1} inhibit M-phase entry of cardiomyocytes which have entered the additional cell cycle. - Highlights: • Many postnatal cardiomyocytes entered an additional cell cycle by cyclin D1 induction. • The majority of cardiomyocytes could not enter M-phase after cyclin D1 induction. • Cell cycle progressed markedly in p21{sup Cip1} knockout mice after postnatal day 14. • Tri- and tetranucleated cardiomyocytes increased in p21{sup Cip1} knockout mice.« less

  15. 29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...

  16. 29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...

  17. 29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...

  18. 29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...

  19. Effect of narrowing the base of support on the gait, gaze and quiet eye of elite ballet dancers and controls.

    PubMed

    Panchuk, Derek; Vickers, Joan N

    2011-08-01

    We determined the gaze and stepping behaviours of elite ballet dancers and controls as they walked normally and along progressively narrower 3-m lines (l0.0, 2.5 cm). The ballet dancers delayed the first step and then stepped more quickly through the approach area and onto the lines, which they exited more slowly than the controls, which stepped immediately but then slowed their gait to navigate the line, which they exited faster. Contrary to predictions, the ballet group did not step more precisely, perhaps due to the unique anatomical requirements of ballet dance and/or due to releasing the degrees of freedom under their feet as they fixated ahead more than the controls. The ballet group used significantly fewer fixations of longer duration, and their final quiet eye (QE) duration prior to stepping on the line was significantly longer (2,353.39 ms) than the controls (1,327.64 ms). The control group favoured a proximal gaze strategy allocating 73.33% of their QE fixations to the line/off the line and 26.66% to the exit/visual straight ahead (VSA), while the ballet group favoured a 'look-ahead' strategy allocating 55.49% of their QE fixations to the exit/VSA and 44.51% on the line/off the line. The results are discussed in the light of the development of expertise and the enhanced role of fixations and visual attention when more tasks become more constrained.

  20. High pressure feeder and method of operating to feed granular or fine materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vimalchand, Pannalal; Liu, Guohai; Peng, Wan Wang

    2014-10-07

    A coal feed system to feed pulverized low rank coals containing up to 25 wt % moisture to gasifiers operating up to 1000 psig pressure is described. The system includes gas distributor and collector gas permeable pipes imbedded in the lock vessel. Different methods of operation of the feed system are disclosed to minimize feed problems associated with bridging and packing of the pulverized coal. The method of maintaining the feed system and feeder device exit pressures using gas addition or extraction with the pressure control device is also described.

  1. High pressure feeder and method of operating to feed granular or fine materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vimalchand, Pannalal; Liu, Guohai; Peng, Wan Wang

    A coal feed system to feed pulverized low rank coals containing up to 25 wt % moisture to gasifiers operating up to 1000 psig pressure is described. The system includes gas distributor and collector gas permeable pipes imbedded in the lock vessel. Different methods of operation of the feed system are disclosed to minimize feed problems associated with bridging and packing of the pulverized coal. The method of maintaining the feed system and feeder device exit pressures using gas addition or extraction with the pressure control device is also described.

  2. Reducing cyclone pressure drop with evasés

    USDA-ARS?s Scientific Manuscript database

    Cyclones are widely used to separate particles from gas flows and as air emissions control devices. Their cost of operation is proportional to the fan energy required to overcome their pressure drop. Evasés or exit diffusers potentially could reduce exit pressure losses without affecting collection...

  3. 30 CFR 57.4530 - Exits for surface buildings and structures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4530 Section 57.4530 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Installation/construction/maintenance § 57.4530 Exits for surface buildings...

  4. 40 CFR 63.107 - Identification of process vents subject to this subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to this subpart. 63.107 Section 63.107 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... going to a fuel gas system as defined in § 63.101. (4) A gas stream exiting a control device used to... transfer operation vent subject to § 63.119 or § 63.126. (8) A vent from a waste management unit subject to...

  5. WRAP low level waste (LLW) glovebox operational test report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kersten, J.K.

    1998-02-19

    The Low Level Waste (LLW) Process Gloveboxes are designed to: receive a 55 gallon drum in an 85 gallon overpack in the Entry glovebox (GBIOI); and open and sort the waste from the 55 gallon drum, place the waste back into drum and relid in the Sorting glovebox (GB 102). In addition, waste which requires further examination is transferred to the LLW RWM Glovebox via the Drath and Schraeder Bagiess Transfer Port (DO-07-201) or sent to the Sample Transfer Port (STC); crush the drum in the Supercompactor glovebox (GB 104); place the resulting puck (along with other pucks) into anothermore » 85 gallon overpack in the Exit glovebox (GB 105). The status of the waste items is tracked by the Data Management System (DMS) via the Plant Control System (PCS) barcode interface. As an item is moved from the entry glovebox to the exit glovebox, the Operator will track an items location using a barcode reader and enter any required data on the DMS console. The Operational Test Procedure (OTP) will perform evolution`s (described below) using the Plant Operating Procedures (POP) in order to verify that they are sufficient and accurate for controlled glovebox operation.« less

  6. 34 CFR 601.21 - Code of conduct.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... students of the institution. (D) Entrance and exit counseling services provided to borrowers to meet the institution's responsibilities for entrance and exit counseling as required by §§ 682.604(f) and 682.604(g), as long as the institution's staff are in control of the counseling (whether in person or via...

  7. Transition duct system with straight ceramic liner for delivering hot-temperature gases in a combustion turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiebe, David J.

    A transition duct system (10) for delivering hot-temperature gases from a plurality of combustors in a combustion turbine engine is provided. The system includes an exit piece (16) for each combustor. The exit piece may include a straight path segment (26) for receiving a gas flow from a respective combustor. A straight ceramic liner (40) may be inwardly disposed onto a metal outer shell (38) along the straight path segment of the exit piece. Structural arrangements are provided to securely attach the ceramic liner in the presence of substantial flow path pressurization. Cost-effective serviceability of the transition duct systems ismore » realizable since the liner can be readily removed and replaced as needed.« less

  8. The Aerothermodynamics of Aircraft Gas Turbine Engines

    DTIC Science & Technology

    1978-07-01

    engine will deteriorate. 1.6.2 Experimental Testing It is easy to fall int9 the organiza- tional trap of four isolated groups . One group does the... Quasi -Dne-Dimensional Fluid Flows The First Law for a F1mdng System-- The Control Volume • . • The Channel Flow Equations Stagnation Properties...exit to control volume (Eq • 2. 14 . 2) CHAPTER TWO THERMODYNAMICS AND QUASI -ONE-DUlENSIONAL FLUID FLO’’{S 2.0 INTRODUCTION This chapter "ill be

  9. Active Pattern Factor Control for Gas Turbine Engines

    NASA Technical Reports Server (NTRS)

    May, James E.

    1998-01-01

    Small variations in fuel/air mixture ratios within gas turbine combustors can result in measurable, and potentially detrimental, exit thermal gradients. Thermal gradients can increase emissions, as well as shorten the design life of downstream turbomachinery, particularly stator vanes. Uniform temperature profiles are usually sought through careful design and manufacturing of related combustor components. However, small componentto-component variations as well as numerous aging effects degrade system performance. To compensate for degraded thermal performance, researchers are investigating active, closed-loop control schemes.

  10. Micro Computer Feedback Report for the Strategic Leader Development Inventory; Source Code

    DTIC Science & Technology

    1994-03-01

    SEL5 ;exit if error CALL SELZCT SCRZEN ;display select screen JC SEL4 ;no files in directory .------- display the files NOV BX, [BarPos] ;starting...SEL2 ;if not goto next test imp SEL4 ; Ecit SEL2: CUP AL,ODh ;in it a pick ? 3Z SEL3 ;if YES exit loop ------- see if an active control key was...file CALL READCOMFIG eread file into memory JC SEL5 ;exit to main menu CALL OPEN DATA FILE ;is data arailable? SEL4 : CALL RELEASE_ _MDR ;release mom

  11. A throat-bypass stability system for a YF-12 aircraft research inlet using self-acting mechanical valves

    NASA Technical Reports Server (NTRS)

    Cole, G. L.; Dustin, M. O.; Neiner, G. H.

    1975-01-01

    Results of a wind tunnel investigation are presented. The inlet was modified so that airflow can be removed through a porous cowl-bleed region in the vicinity of the throat. Bleed plenum exit flow area is controlled by relief type mechanical valves. Unlike valves in previous systems, these are made for use in a high Mach flight environment and include refinements so that the system could be tested on a NASA YF-12 aircraft. The valves were designed to provide their own reference pressure. The results show that the system can absorb internal-airflow-transients that are too fast for a conventional bypass door control system and that the two systems complement each other quite well. Increased tolerance to angle of attack and Mach number changes is indicated. The valves should provide sufficient time for the inlet control system to make geometry changes required to keep the inlet started.

  12. Transgenic C. elegans dauer larvae expressing hookworm phospho null DAF-16/FoxO exit dauer.

    PubMed

    Gelmedin, Verena; Brodigan, Thomas; Gao, Xin; Krause, Michael; Wang, Zhu; Hawdon, John M

    2011-01-01

    Parasitic hookworms and the free-living model nematode Caenorhabtidis elegans share a developmental arrested stage, called the dauer stage in C. elegans and the infective third-stage larva (L3) in hookworms. One of the key transcription factors that regulate entrance to and exit from developmental arrest is the forkhead transcription factor DAF-16/FoxO. During the dauer stage, DAF-16 is activated and localized in the nucleus. DAF-16 is negatively regulated by phosphorylation by the upstream kinase AKT, which causes DAF-16 to localize out of the nucleus and the worm to exit from dauer. DAF-16 is conserved in hookworms, and hypothesized to control recovery from L3 arrest during infection. Lacking reverse genetic techniques for use in hookworms, we used C. elegans complementation assays to investigate the function of Ancylostoma caninum DAF-16 during entrance and exit from L3 developmental arrest. We performed dauer switching assays and observed the restoration of the dauer phenotype when Ac-DAF-16 was expressed in temperature-sensitive dauer defective C. elegans daf-2(e1370);daf-16(mu86) mutants. AKT phosphorylation site mutants of Ac-DAF-16 were also able to restore the dauer phenotype, but surprisingly allowed dauer exit when temperatures were lowered. We used fluorescence microscopy to localize DAF-16 during dauer and exit from dauer in C. elegans DAF-16 mutant worms expressing Ac-DAF-16, and found that Ac-DAF-16 exited the nucleus during dauer exit. Surprisingly, Ac-DAF-16 with mutated AKT phosphorylation sites also exited the nucleus during dauer exit. Our results suggest that another mechanism may be involved in the regulation DAF-16 nuclear localization during recovery from developmental arrest.

  13. Statistical analysis of AFE GN&C aeropass performance

    NASA Technical Reports Server (NTRS)

    Chang, Ho-Pen; French, Raymond A.

    1990-01-01

    Performance of the guidance, navigation, and control (GN&C) system used on the Aeroassist Flight Experiment (AFE) spacecraft has been studied with Monte Carlo techniques. The performance of the AFE GN&C is investigated with a 6-DOF numerical dynamic model which includes a Global Reference Atmospheric Model (GRAM) and a gravitational model with oblateness corrections. The study considers all the uncertainties due to the environment and the system itself. In the AFE's aeropass phase, perturbations on the system performance are caused by an error space which has over 20 dimensions of the correlated/uncorrelated error sources. The goal of this study is to determine, in a statistical sense, how much flight path angle error can be tolerated at entry interface (EI) and still have acceptable delta-V capability at exit to position the AFE spacecraft for recovery. Assuming there is fuel available to produce 380 ft/sec of delta-V at atmospheric exit, a 3-sigma standard deviation in flight path angle error of 0.04 degrees at EI would result in a 98-percent probability of mission success.

  14. Adaptive optics retinal imaging with automatic detection of the pupil and its boundary in real time using Shack-Hartmann images.

    PubMed

    de Castro, Alberto; Sawides, Lucie; Qi, Xiaofeng; Burns, Stephen A

    2017-08-20

    Retinal imaging with an adaptive optics (AO) system usually requires that the eye be centered and stable relative to the exit pupil of the system. Aberrations are then typically corrected inside a fixed circular pupil. This approach can be restrictive when imaging some subjects, since the pupil may not be round and maintaining a stable head position can be difficult. In this paper, we present an automatic algorithm that relaxes these constraints. An image quality metric is computed for each spot of the Shack-Hartmann image to detect the pupil and its boundary, and the control algorithm is applied only to regions within the subject's pupil. Images on a model eye as well as for five subjects were obtained to show that a system exit pupil larger than the subject's eye pupil could be used for AO retinal imaging without a reduction in image quality. This algorithm automates the task of selecting pupil size. It also may relax constraints on centering the subject's pupil and on the shape of the pupil.

  15. The Role of Drosophila Merlin in the Control of Mitosis Exit and Development

    DTIC Science & Technology

    2008-07-01

    identification of new genes may not yield a clear indication of their respective functions , studies on their evolution may allow validation of their...in the elongated Nebenkern (Figure 2H). In addi- tion, Merlin was seen as a bright punctate dot in the acro- somal region, a Golgi apparatus -derived... functions as a tumor suppressor, we have confirmed that Drosophila Merlin plays important roles in the control of mitosis exit and in the

  16. 40 CFR Table 24 to Subpart Uuu of... - Continuous Monitoring Systems for Inorganic HAP Emissions From Catalytic Reforming Units

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... entering the scrubber during coke burn-off and catalyst rejuvenation; and continuous parameter monitoring system to measure and record gas flow rate entering or exiting the scrubber during coke burn-off and... alkalinity of the water (or scrubbing liquid) exiting the scrubber during coke burn-off and catalyst...

  17. Control algorithms for aerobraking in the Martian atmosphere

    NASA Technical Reports Server (NTRS)

    Ward, Donald T.; Shipley, Buford W., Jr.

    1991-01-01

    The Analytic Predictor Corrector (APC) and Energy Controller (EC) atmospheric guidance concepts were adapted to control an interplanetary vehicle aerobraking in the Martian atmosphere. Changes are made to the APC to improve its robustness to density variations. These changes include adaptation of a new exit phase algorithm, an adaptive transition velocity to initiate the exit phase, refinement of the reference dynamic pressure calculation and two improved density estimation techniques. The modified controller with the hybrid density estimation technique is called the Mars Hybrid Predictor Corrector (MHPC), while the modified controller with a polynomial density estimator is called the Mars Predictor Corrector (MPC). A Lyapunov Steepest Descent Controller (LSDC) is adapted to control the vehicle. The LSDC lacked robustness, so a Lyapunov tracking exit phase algorithm is developed to guide the vehicle along a reference trajectory. This algorithm, when using the hybrid density estimation technique to define the reference path, is called the Lyapunov Hybrid Tracking Controller (LHTC). With the polynomial density estimator used to define the reference trajectory, the algorithm is called the Lyapunov Tracking Controller (LTC). These four new controllers are tested using a six degree of freedom computer simulation to evaluate their robustness. The MHPC, MPC, LHTC, and LTC show dramatic improvements in robustness over the APC and EC.

  18. Approaches to Debugging at Scale on the Peregrine System | High-Performance

    Science.gov Websites

    nodes=100 walltime=1:00:00:00 -A CSC001 This asks for 100 nodes for 1 day. When the nodes are available interactive debugger such as TotalView. When you are done working, exit the queue-name When you want to disconnect from the session, type control-A then d. The interactive job

  19. Effect of slotted exit orifice on performance of plasma synthetic jet actuator

    NASA Astrophysics Data System (ADS)

    Zong, Haohua; Kotsonis, Marios

    2017-03-01

    This study experimentally investigates the influence of exit orifice shape on the performance characteristics of a three-electrode plasma synthetic jet actuator. High-speed Schlieren imaging system and phase-locked two-component PIV measurements are used for flowfield characterisation in quiescent conditions. Two actuator configurations with the same exit area but different exit orifice shape (round orifice and slot orifice) are studied. Results indicate a close correspondence between the shapes of the starting vortex ring with the shapes of the respective exit orifices. For the slot orifice, the elongated starting vortex ring gradually expands during propagation, while its ends become warped. A distinct K-H instability structure is observed, inducing continuous oscillation of the high-speed jet. Compared with the jet from the round orifice, the slot jet has a higher entrainment rate of surrounding air, thus resulting in a lower propagation velocity of the jet front. The exit velocity of PSJA within one period initially shows a rapid increase, then persists at a relatively high level (100-130 m/s), and finally drops with some small-scale oscillations. The oscillation amplitude is less than 10 m/s, and the oscillation period is approximately 600 µs. Under conditions of same exit area, orifice shape has little influence on the variation of the exit velocity.

  20. Transition duct system with metal liners for delivering hot-temperature gases in a combustion turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiebe, David J.

    A transition duct system (10) for delivering hot-temperature gases from a plurality of combustors in a combustion turbine engine is provided. The system includes an exit piece (16) for each combustor. The exit piece may include a straight path segment (26) and an arcuate connecting segment (36). A respective straight metal liner (92) and an arcuate metal liner (94) may be each inwardly disposed onto a metal outer shell (38) along the straight path segment and the arcuate connecting segment (36) of the exit piece. Structural arrangements are provided to securely attach the respective liners in the presence of substantialmore » flow path pressurization. Cost-effective serviceability of the transition duct systems is realizable since the liners can be readily removed and replaced as needed.« less

  1. Antibacterial honey for the prevention of peritoneal-dialysis-related infections (HONEYPOT): a randomised trial.

    PubMed

    Johnson, David W; Badve, Sunil V; Pascoe, Elaine M; Beller, Elaine; Cass, Alan; Clark, Carolyn; de Zoysa, Janak; Isbel, Nicole M; McTaggart, Steven; Morrish, Alicia T; Playford, E Geoffrey; Scaria, Anish; Snelling, Paul; Vergara, Liza A; Hawley, Carmel M

    2014-01-01

    There is a paucity of evidence to guide the best strategy for prevention of peritoneal-dialysis-related infections. Antibacterial honey has shown promise as a novel, cheap, effective, topical prophylactic agent without inducing microbial resistance. We therefore assessed whether daily application of honey at the exit site would increase the time to peritoneal-dialysis-related infections compared with standard exit-site care plus intranasal mupirocin prophylaxis for nasal carriers of Staphylococcus aureus. In this open-label trial undertaken in 26 centres in Australia and New Zealand, participants undergoing peritoneal dialysis were randomly assigned in a 1:1 ratio with an adaptive allocation algorithm to daily topical exit-site application of antibacterial honey plus standard exit-site care or intranasal mupirocin prophylaxis (only in carriers of nasal S aureus) plus standard exit-site care (control group). The primary endpoint was time to first infection related to peritoneal dialysis (exit-site infection, tunnel infection, or peritonitis). The trial is registered with the Australian New Zealand Clinical Trials Registry, number 12607000537459. Of 371 participants, 186 were assigned to the honey group and 185 to the control group. The median peritoneal-dialysis-related infection-free survival times were not significantly different in the honey (16·0 months [IQR not estimable]) and control groups (17·7 months [not estimable]; unadjusted hazard ratio 1·12, 95% CI 0·83-1·51; p=0·47). In the subgroup analyses, honey increased the risks of both the primary endpoint (1·85, 1·05-3·24; p=0·03) and peritonitis (2·25, 1·16-4·36) in participants with diabetes. The incidences of serious adverse events (298 vs 327, respectively; p=0·1) and deaths (14 vs 18, respectively; p=0·9) were not significantly different in the honey and control groups. 11 (6%) participants in the honey group had local skin reactions. The findings of this trial show that honey cannot be recommended routinely for the prevention of peritoneal-dialysis-related infections. Baxter Healthcare, Queensland Government, Comvita, and Gambro. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Convair XF-102 Model in the 8- by 6-Foot Supersonic Wind Tunnel

    NASA Image and Video Library

    1953-08-21

    A .10-scale model of Convair’s XF-102 in the 8- by 6-Foot Supersonic Wind Tunnel at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory for jet exit studies. The XF-102 was a prototype of the F-102 Delta Dagger. The F-102 served as an interceptor against long range bombers from the Soviet Union. The aircraft was powered by a Pratt and Whitney J57 turbojet. The first prototype crashed two weeks after is first flight on October 24, 1953, just months after this photograph. Engineers then incorporated the fixed-wing design to reduce drag at supersonic speeds. The production model F-102 became the first delta-wing supersonic aircraft in operation. The 8- by 6-Foot Supersonic Wind Tunnel is used to study propulsion systems, including inlets and exit nozzles, combustion fuel injectors, flame holders, exit nozzles, and controls on ramjet and turbojet engines. Flexible sidewalls alter the tunnel’s nozzle shape to vary the Mach number during operation. A seven-stage axial compressor, driven by three electric motors that yield a total of 87,000 horsepower, generates air speeds from Mach 0.36 to 2.0.

  3. 15. NBS TOP SIDE CONTROL ROOM. THE SUIT SYSTEMS CONSOLE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. NBS TOP SIDE CONTROL ROOM. THE SUIT SYSTEMS CONSOLE IS USED TO CONTROL AIR FLOW AND WATER FLOW TO THE UNDERWATER SPACE SUIT DURING THE TEST. THE SUIT SYSTEMS ENGINEER MONITORS AIR FLOW ON THE PANEL TO THE LEFT, AND SUIT DATA ON THE COMPUTER MONITOR JUST SLIGHTLY TO HIS LEFT. WATER FLOW IS MONITORED ON THE PANEL JUST SLIGHTLY TO HIS RIGHT AND TEST VIDEO TO HIS FAR RIGHT. THE DECK CHIEF MONITORS THE DIVER'S DIVE TIMES ON THE COMPUTER IN THE UPPER RIGHT. THE DECK CHIEF LOGS THEM IN AS THEY ENTER THE WATER, AND LOGS THEM OUT AS THEY EXIT THE WATER. THE COMPUTER CALCULATES TOTAL DIVE TIME. - Marshall Space Flight Center, Neutral Buoyancy Simulator Facility, Rideout Road, Huntsville, Madison County, AL

  4. Organized medicine and Scandinavian professional unionism: hospital policies and exit options in Denmark and Sweden.

    PubMed

    Heidenheimer, A J; Johansen, L N

    1985-01-01

    Strikes by junior hospital doctors over the issue of on-call remuneration in Denmark and Sweden in 1981 are analyzed to clarify the impact of public-sector cost-control policies on intra- and interprofessional solidarity within the Scandinavian professional peak associations. The junior doctors' grievances could find expression either through increased "voice" within the medical negotiating machinery, or by pursuing the exit option in having the medical associations quit the peak associations. The article explains why the "exit" option was selected in Denmark, while in Sweden the granting of additional voice helped persuade the medical association to withdraw its exit threat and to remain within the peak association. The two cases are interpreted as presaging a divergence in the paths being taken by the various Scandinavian welfare states.

  5. Development of the Circulation Control Flow Scheme Used in the NTF Semi-Span FAST-MAC Model

    NASA Technical Reports Server (NTRS)

    Jones, Gregory S.; Milholen, William E., II; Chan, David T.; Allan, Brian G.; Goodliff, Scott L.; Melton, Latunia P.; Anders, Scott G.; Carter, Melissa B.; Capone, Francis J.

    2013-01-01

    The application of a circulation control system for high Reynolds numbers was experimentally validated with the Fundamental Aerodynamic Subsonic Transonic Modular Active Control semi-span model in the NASA Langley National Transonic Facility. This model utilized four independent flow paths to modify the lift and thrust performance of a representative advanced transport type of wing. The design of the internal flow paths highlights the challenges associated with high Reynolds number testing in a cryogenic pressurized wind tunnel. Weight flow boundaries for the air delivery system were identified at mildly cryogenic conditions ranging from 0.1 to 10 lbm/sec. Results from the test verified system performance and identified solutions associated with the weight-flow metering system that are linked to internal perforated plates used to achieve flow uniformity at the jet exit.

  6. The effect of nozzle-exit-channel shape on resultant fiber diameter in melt-electrospinning

    NASA Astrophysics Data System (ADS)

    Esmaeilirad, Ahmad; Ko, Junghyuk; Rukosuyev, Maxym V.; Lee, Jason K.; Lee, Patrick C.; Jun, Martin B. G.

    2017-01-01

    In recent decades, electrospinning using a molten poly (ε-caprolactone) resin has gained attention for creating fibrous tissue scaffolds. The topography and diameter control of such electrospun microfibers is an important issue for their different applications in tissue engineering. Charge density, initial nozzle-exit-channel cross-sectional area, nozzle to collector distance, viscosity, and processing temperature are the most important input parameters that affect the final electrospun fiber diameters. In this paper we will show that the effect of nozzle-exit-channel shape is as important as the other effective parameters in a resultant fiber diameter. However, to the best of our knowledge, the effect of nozzle-exit-channel shapes on a resultant fiber diameter have not been studied before. Comparing rectangular and circular nozzles with almost the same exit-channel cross-sectional areas in a similar processing condition showed that using a rectangular nozzle resulted in decreasing final fiber diameter up to 50%. Furthermore, the effect of processing temperature on the final fiber topography was investigated.

  7. 46th Annual Gun and Missile Systems Conference and Exhibition. Volume 3 - Thursday

    DTIC Science & Technology

    2011-09-01

    Grade Sensors Through Use of Accelerated Aging Principles Mr. Scott Gift 11657 Modeling of the Autofrettage Processes of a Gun Barrel Mr. Sudhir...Emissions Measured on the Outer Portion of a Composite Barrel Ms. Rushie Ghimire GUN & MISSILE SYSTEMS ADDITIONAL AUTHORS GUN & MISSILE SYSTEMS...Transportation – Loading – Gun Fire to Barrel Exit – After Barrel Exit • Passing: Fuze safety devices remain safe; safe for disposal or safe for

  8. Residence Hall Fires.

    ERIC Educational Resources Information Center

    Wright, Dorothy

    1999-01-01

    Discusses how one college's experience with a tragic fire in one of its residence halls prompted a reevaluation of its fire-prevention-and-response strategies. Staff training, sprinkler installation, new alarm systems, and exit hardware to help make building exiting more efficient are discussed. (GR)

  9. [Application of traditional Chinese medicine reference standards in quality control of Chinese herbal pieces].

    PubMed

    Lu, Tu-Lin; Li, Jin-Ci; Yu, Jiang-Yong; Cai, Bao-Chang; Mao, Chun-Qin; Yin, Fang-Zhou

    2014-01-01

    Traditional Chinese medicine (TCM) reference standards plays an important role in the quality control of Chinese herbal pieces. This paper overviewed the development of TCM reference standards. By analyzing the 2010 edition of Chinese pharmacopoeia, the application of TCM reference standards in the quality control of Chinese herbal pieces was summarized, and the problems exiting in the system were put forward. In the process of improving the quality control level of Chinese herbal pieces, various kinds of advanced methods and technology should be used to research the characteristic reference standards of Chinese herbal pieces, more and more reasonable reference standards should be introduced in the quality control system of Chinese herbal pieces. This article discussed the solutions in the aspect of TCM reference standards, and future development of quality control on Chinese herbal pieces is prospected.

  10. Simple systems for treating pumped, turbid water with flocculants and a geotextile dewatering bag.

    PubMed

    Kang, Jihoon; McLaughlin, Richard A

    2016-11-01

    Pumping sediment-laden water from excavations is often necessary on construction sites. This water is often treated by pumping it through geotextile dewatering bags. The bags are not designed to filter the fine sediments that create high turbidity, but dosing with a flocculant prior to the bag could result in greater turbidity control. This study compared two systems for introducing flocculant: passive dosing of commercial solid biopolymer (chitosan) and injection of dissolved polyacrylamide (PAM) in a length of corrugated pipe connected to the bag. The biopolymer system consisted of sequential porous socks containing a "charging agent" followed by chitosan in the corrugated pipe with two levels of dosing. The dissolved PAM was injected into turbid water at a flow-weighted concentration at 1 mg L(-1). For each treatment, sediment-laden turbid water in the range of 2000 to 3500 nephelometric turbidity units (NTU) was pumped into the upstream of corrugated pipe and samples were taken from pipe entrance, pipe exit, and dewatering bag exit. Without flocculant treatment, the dewatering bag reduced turbidity by 70% but the addition of flocculant increased the turbidity reduction up to 97% relative to influent. At the pipe exit, the low-dose biopolymer was less effective in reducing turbidity (37%) but it was equally effective as the high-dose biopolymer or PAM injection after the bag. Our results suggest that a relatively simple treatment with flocculants, either passively or actively, can be very effective in reducing turbidity for pumped water on construction sites. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Self-actuated nuclear reactor shutdown system using induction pump to facilitate sensing of core coolant temperature

    DOEpatents

    Sievers, Robert K.; Cooper, Martin H.; Tupper, Robert B.

    1987-01-01

    A self-actuated shutdown system incorporated into a reactivity control assembly in a nuclear reactor includes pumping means for creating an auxiliary downward flow of a portion of the heated coolant exiting from the fuel assemblies disposed adjacent to the control assembly. The shutdown system includes a hollow tubular member which extends through the outlet of the control assembly top nozzle so as to define an outer annular flow channel through the top nozzle outlet separate from an inner flow channel for primary coolant flow through the control assembly. Also, a latching mechanism is disposed in an inner duct of the control assembly and is operable for holding absorber bundles in a raised position in the control assembly and for releasing them to drop them into the core of the reactor for shutdown purposes. The latching mechanism has an inner flow passage extending between and in flow communication with the absorber bundles and the inner flow channel of the top nozzle for accommodating primary coolant flow upwardly through the control assembly. Also, an outer flow passage separate from the inner flow passage extends through the latching mechanism between and in flow communication with the inner duct and the outer flow channel of the top nozzle for accommodating inflow of a portion of the heated coolant from the adjacent fuel assemblies. The latching mechanism contains a magnetic material sensitive to temperature and operable to cause mating or latching together of the components of the latching mechanism when the temperature sensed is below a known temperature and unmating or unlatching thereof when the temperature sensed is above a given temperature. The temperature sensitive magnetic material is positioned in communication with the heated coolant flow through the outer flow passage for directly sensing the temperature thereof. Finally, the pumping means includes a jet induction pump nozzle and diffuser disposed adjacent the bottom nozzle of the control assembly and in flow communication with the inlet thereof. The pump nozzle is operable to create an upward driving flow of primary coolant through the pump diffuser and then to the absorber bundles. The upward driving flow of primary coolant, in turn, creates a suction head within the outer flow channel of the top nozzle and thereby an auxiliary downward flow of the heated coolant portion exiting from the upper end of the adjacent fuel assemblies through the outer flow channel to the pump nozzle via the outer flow passage of the latching mechanism and an annular space between the outer and inner spaced ducts of the control assembly housing. The temperature of the heated coolant exiting from the adjacent fuel assemblies can thereby be sensed directly by the temperature sensitive magnetic material in the latching mechanism.

  12. Dynamic response of a Mach 2.5 axisymmetric inlet and turbojet engine with a poppet-value controlled inlet stability bypass system when subjected to internal and external airflow transients

    NASA Technical Reports Server (NTRS)

    Sanders, B. W.

    1980-01-01

    The throat of a Mach 2.5 inlet that was attached to a turbojet engine was fitted with a poppet-valve-controlled stability bypass system that was designed to provide a large, stable airflow range. Propulsion system response and stability bypass performance were determined for several transient airflow disturbances, both internal and external. Internal airflow disturbances included reductions in overboard bypass airflow, power lever angle, and primary-nozzle area as well as compressor stall. For reference, data are also included for a conventional, fixed-exit bleed system. The poppet valves greatly increased inlet stability and had no adverse effects on propulsion system performance. Limited unstarted-inlet bleed performance data are presented.

  13. Modeling the use of a binary mixture as a control scheme for two-phase thermal systems

    NASA Technical Reports Server (NTRS)

    Benner, S. M.; Costello, Frederick A.

    1990-01-01

    Two-phase thermal loops using mechanical pumps, capillary pumps, or a combination of the two have been chosen as the main heat transfer systems for the space station. For these systems to operate optimally, the flow rate in the loop should be controlled in response to the vapor/liquid ratio leaving the evaporator. By substituting a mixture of two non-azeotropic fluids in place of the single fluid normally used in these systems, it may be possible to monitor the temperature of the exiting vapor and determine the vapor/liquid ratio. The flow rate would then be adjusted to maximize the load capability with minimum energy input. A FLUINT model was developed to study the system dynamics of a hybrid capillary pumped loop using this type of control and was found to be stable under all the test conditions.

  14. Control of Malaria Vector Mosquitoes by Insecticide-Treated Combinations of Window Screens and Eave Baffles.

    PubMed

    Killeen, Gerry F; Masalu, John P; Chinula, Dingani; Fotakis, Emmanouil A; Kavishe, Deogratius R; Malone, David; Okumu, Fredros

    2017-05-01

    We assessed window screens and eave baffles (WSEBs), which enable mosquitoes to enter but not exit houses, as an alternative to indoor residual spraying (IRS) for malaria vector control. WSEBs treated with water, the pyrethroid lambda-cyhalothrin, or the organophosphate pirimiphos-methyl, with and without a binding agent for increasing insecticide persistence on netting, were compared with IRS in experimental huts. Compared with IRS containing the same insecticide, WSEBs killed similar proportions of Anopheles funestus mosquitoes that were resistant to pyrethroids, carbamates and organochlorines and greater proportions of pyrethroid-resistant, early exiting An. arabiensis mosquitoes. WSEBs with pirimiphos-methyl killed greater proportions of both vectors than lambda-cyhalothrin or lambda-cyhalothrin plus pirimiphos-methyl and were equally efficacious when combined with binding agent. WSEBs required far less insecticide than IRS, and binding agents might enhance durability. WSEBs might enable affordable deployment of insecticide combinations to mitigate against physiologic insecticide resistance and improve control of behaviorally resistant, early exiting vectors.

  15. Epigenetics as a First Exit Problem

    NASA Astrophysics Data System (ADS)

    Aurell, E.; Sneppen, K.

    2002-01-01

    We develop a framework to discuss the stability of epigenetic states as first exit problems in dynamical systems with noise. We consider in particular the stability of the lysogenic state of the λ prophage. The formalism defines a quantitative measure of robustness of inherited states.

  16. "I Wish to Be Self-Reliant": Aspiration for Self-Reliance, Need and Life Satisfaction, and Exit Dilemma of Welfare Recipients in Hong Kong

    ERIC Educational Resources Information Center

    Wong, Chack-Kie; Lou, Vivian Wei-Qun

    2010-01-01

    This qualitative study explores the welfare recipients' experiences of and attitudes toward the welfare benefit system in Hong Kong. A sample of 19 welfare recipients from six main recipient groups was interviewed, some twice. This study finds that the recipients have strong aspirations to exit the welfare benefit system. The welfare application…

  17. Liquid Level Sensing System

    NASA Technical Reports Server (NTRS)

    Korman, Valentin (Inventor); Wiley, John T. (Inventor); Duffell, Amanda G. (Inventor)

    2014-01-01

    A liquid level sensing system includes waveguides disposed in a liquid and distributed along a path with a gap between adjacent waveguides. A source introduces electromagnetic energy into the waveguides at a first end of the path. A portion of the electromagnetic energy exits the waveguides at a second end of the path. A detector measures the portion of the electromagnetic energy exiting the second end of the path.

  18. Exit, Voice, and Loyalty in the Italian Public Health Service: Macroeconomic and Corporate Implications

    PubMed Central

    Impagliazzo, Cira; Zoccoli, Paola

    2013-01-01

    The paper analyses how customers of public health organizations can express their dissatisfaction for the services offered to them. The main aim is to evaluate the effects that possible dissatisfaction of Italian public health service customers can have on public health organizations. We adopted the methodological scheme developed by Hirschman with exit, voice, and loyalty, considering the macroeconomic and corporate implications that it causes for Italian public health organizations. The study investigated the effects developed by exit of the patients on the system of financing of local health authorities considering both the corporate level of analysis and the macroeconomic level. As a result, local health authority management is encouraged to pay greater attention to the exit phenomena through the adoption of tools that promote loyalty, such as the promotion of voice, even if exit is not promoting, at a macroeconomic level, considerable attention to this phenomenon. PMID:24348148

  19. Exit, voice, and loyalty in the Italian public health service: macroeconomic and corporate implications.

    PubMed

    Ippolito, Adelaide; Impagliazzo, Cira; Zoccoli, Paola

    2013-01-01

    The paper analyses how customers of public health organizations can express their dissatisfaction for the services offered to them. The main aim is to evaluate the effects that possible dissatisfaction of Italian public health service customers can have on public health organizations. We adopted the methodological scheme developed by Hirschman with exit, voice, and loyalty, considering the macroeconomic and corporate implications that it causes for Italian public health organizations. The study investigated the effects developed by exit of the patients on the system of financing of local health authorities considering both the corporate level of analysis and the macroeconomic level. As a result, local health authority management is encouraged to pay greater attention to the exit phenomena through the adoption of tools that promote loyalty, such as the promotion of voice, even if exit is not promoting, at a macroeconomic level, considerable attention to this phenomenon.

  20. Pregabalin monotherapy in patients with partial-onset seizures

    PubMed Central

    Kwan, Patrick; Fakhoury, Toufic; Pitman, Verne; DuBrava, Sarah; Knapp, Lloyd; Yurkewicz, Lorraine

    2014-01-01

    Objective: To assess pregabalin monotherapy for partial-onset seizures using a historical-controlled conversion-to-monotherapy design. Methods: Adults with inadequately controlled partial-onset seizures while receiving 1 or 2 antiepileptic drugs during an 8-week prospective baseline were randomized to double-blind monotherapy with pregabalin 600 or 150 mg/d (4:1) for 20 weeks (8-week conversion and 12-week monotherapy period). The primary endpoint was the seizure-related exit rate for pregabalin 600 mg/d, based on discontinuations due to predefined criteria. Efficacy was declared if the upper limit of the 95% confidence interval for the exit rate was below a historical-control threshold of 74%, with stepwise evaluation using a threshold of 68%. Results: The trial was stopped early for positive efficacy after an interim analysis in 125 patients. The full study population included 161 patients, with 148 evaluable for efficacy. The mean time since epilepsy diagnosis was 14 years. Overall, 54.3% (600 mg/d) and 46.9% (150 mg/d) of patients completed 20 weeks of double-blind treatment. Seizure-related exit rate in the 600 mg/d group (27.5%; 95% confidence interval, 17.8%–37.2%) was significantly below the 74% and 68% thresholds (p < 0.001 for both). Eight patients on 600 mg/d and 2 on 150 mg/d were seizure-free throughout pregabalin monotherapy. Pregabalin's overall safety profile was consistent with prior trials. Conclusions: Pregabalin monotherapy was safe and efficacious for patients with inadequately controlled partial-onset seizures. Classification of evidence: This study provides Class III evidence that patients with inadequately controlled partial-onset seizures switched to pregabalin monotherapy have fewer seizure-related exit events compared with historical controls switched to pseudo-placebo monotherapy. PMID:24415567

  1. Tests of a D vented thrust deflecting nozzle behind a simulated turbofan engine

    NASA Technical Reports Server (NTRS)

    Watson, T. L.

    1982-01-01

    A D vented thrust deflecting nozzle applicable to subsonic V/STOL aircraft was tested behind a simulated turbofan engine in the verticle thrust stand. Nozzle thrust, fan operating characteristics, nozzle entrance conditions, and static pressures were measured. Nozzle performance was measured for variations in exit area and thrust deflection angle. Six core nozzle configurations, the effect of core exit axial location, mismatched core and fan stream nozzle pressure ratios, and yaw vane presence were evaluated. Core nozzle configuration affected performance at normal and engine out operating conditions. Highest vectored nozzle performance resulted for a given exit area when core and fan stream pressure were equal. Its is concluded that high nozzle performance can be maintained at both normal and engine out conditions through control of the nozzle entrance Mach number with a variable exit area.

  2. Development of a Permitting Strategy for a Coal-Fired Heating Plant, K.I. Sawyer AFB, Maine.

    DTIC Science & Technology

    1982-12-01

    that the proposed control system is BACT for controlling total suspended particulates. Under PSD review for SO2, application of BACT might require flue ... gas desulfurization and/or burning low sulfur coal. One solution to avoid BACT review for SO2 would be to limit the sulfur content of coal...existing five boilers. 3-23 i. _ - -’••-’•-’-"«--• .-*.’-.’. and combustion air at a maximum of 350°F. The corresponding flue gas exit temperature

  3. Cholesterol regulates the endoplasmic reticulum exit of the major membrane protein P0 required for peripheral myelin compaction.

    PubMed

    Saher, Gesine; Quintes, Susanne; Möbius, Wiebke; Wehr, Michael C; Krämer-Albers, Eva-Maria; Brügger, Britta; Nave, Klaus-Armin

    2009-05-13

    Rapid impulse conduction requires electrical insulation of axons by myelin, a cholesterol-rich extension of the glial cell membrane with a characteristic composition of proteins and lipids. Mutations in several myelin protein genes cause endoplasmic reticulum (ER) retention and disease, presumably attributable to failure of misfolded proteins to pass the ER quality control. Because many myelin proteins partition into cholesterol-rich membrane rafts, their interaction with cholesterol could potentially be part of the ER quality control system. Here, we provide in vitro and in vivo evidence that the major peripheral myelin protein P0 requires cholesterol for exiting the ER and reaching the myelin compartment. Cholesterol dependency of P0 trafficking in heterologous cells is mediated by a cholesterol recognition/interaction amino acid consensus (CRAC) motif. Mutant mice lacking cholesterol biosynthesis in Schwann cells suffer from severe hypomyelination with numerous uncompacted myelin stretches. This demonstrates that high-level cholesterol coordinates P0 export with myelin membrane synthesis, which is required for the correct stoichiometry of myelin components and for myelin compaction.

  4. Performance recovery of a class of uncertain non-affine systems with unmodelled dynamics: an indirect dynamic inversion method

    NASA Astrophysics Data System (ADS)

    Yi, Bowen; Lin, Shuyi; Yang, Bo; Zhang, Weidong

    2018-02-01

    This paper presents an output feedback indirect dynamic inversion (IDI) approach for a class of uncertain nonaffine systems with input unmodelled dynamics. Compared with previous approaches to achieve performance recovery, the proposed method aims at dealing with a broader class of nonaffine-in-control systems with triangular structure. An IDI state feedback law is designed first, in which less knowledge of the model plant is needed compared to earlier approximate dynamic inversion methods, thus yielding more robust performance. After that, an extended high-gain observer is designed to accomplish the task with output feedback. Finally, we prove that the designed IDI controller is equivalent to an adaptive proportional-integral (PI) controller, with respect to both time response equivalence and robustness equivalence. The conclusion implies that for the studied strict-feedback non-affine systems with unmodelled dynamics, there always exits a PI controller to stabilise the systems. The effectiveness and benefits of the designed approach are verified by three examples.

  5. Turbine exhaust diffuser with a gas jet producing a coanda effect flow control

    DOEpatents

    Orosa, John; Montgomery, Matthew

    2014-02-11

    An exhaust diffuser system and method for a turbine engine includes an inner boundary and an outer boundary with a flow path defined therebetween. The inner boundary is defined at least in part by a hub structure that has an upstream end and a downstream end. The outer boundary may include a region in which the outer boundary extends radially inward toward the hub structure and may direct at least a portion of an exhaust flow in the diffuser toward the hub structure. The hub structure includes at least one jet exit located on the hub structure adjacent to the upstream end of the tail cone. The jet exit discharges a flow of gas substantially tangential to an outer surface of the tail cone to produce a Coanda effect and direct a portion of the exhaust flow in the diffuser toward the inner boundary.

  6. Method and apparatus for strip casting

    DOEpatents

    Follstaedt, Donald W.; Powell, John C.; Sussman, Richard C.; Williams, Robert S.

    1991-01-01

    Casting nozzles will provide improved flow conditions with the parameters controlled according to the present invention. The gap relationships between the nozzle slot and exit orifice must be controlled in combination with converging exit passageway to provide a smooth flow without shearing and turbulence in the stream. The nozzle lips are also rounded to improve flow and increase refractory life of the lips of the nozzle. The tundish walls are tapered to provide improve flow for supplying the melt to the nozzle. The nozzle is located about 45.degree. below top dead center for optimum conditions.

  7. A Compendium of Solar Dish/Stirling Technology

    DTIC Science & Technology

    1994-01-01

    systems and Plataforma Solar in Almeria, Spain, with the goal being plans to produce fourteen 7.5-kWe systems for testing to test the system’s long-term...the sun is not a point source, its rays 21 Chapter 3 (a) (b) - N Mounting Ring and CollaraI/ / I/\\ I / Virtual Exit I / Target S• Entrance I 0 L...tptical \\ I Real Exit / Virtual Target \\ Aperture\\ / Cooling \\ / I Coils N - Focal - - - - " Plane 4. Figure 3-2. A secondary concentrator with side view (a

  8. Changes in the Autism Behavioral Phenotype during the Transition to Adulthood

    PubMed Central

    Taylor, Julie Lounds; Seltzer, Marsha Mailick

    2010-01-01

    We examined whether exiting high school was associated with alterations in rates of change in autism symptoms and maladaptive behaviors. Participants were 242 youth with ASD who had recently exited the school system and were part of our larger longitudinal study; data were collected at five time points over nearly 10 years. Results indicated overall improvement of autism symptoms and internalized behaviors over the study period, but slowing rates of improvement after exit. Youth who did not have an intellectual disability evidenced the greatest slowing in improvement. Lower family income was associated with less improvement. Our findings suggest that adult day activities may not be as intellectually stimulating as educational activities in school, reflected by less phenotypic improvement after exit. PMID:20361245

  9. IR signature study of aircraft engine for variation in nozzle exit area

    NASA Astrophysics Data System (ADS)

    Baranwal, Nidhi; Mahulikar, Shripad P.

    2016-01-01

    In general, jet engines operate with choked nozzle during take-off, climb and cruise, whereas unchoking occurs while landing and taxiing (when engine is not running at full power). Appropriate thrust in an aircraft in all stages of the flight, i.e., take-off, climb, cruise, descent and landing is achieved through variation in the nozzle exit area. This paper describes the effect on thrust and IR radiance of a turbojet engine due to variation in the exit area of a just choked converging nozzle (Me = 1). The variations in the nozzle exit area result in either choking or unchoking of a just choked converging nozzle. Results for the change in nozzle exit area are analyzed in terms of thrust, mass flow rate and specific fuel consumption. The solid angle subtended (Ω) by the exhaust system is estimated analytically, for the variation in nozzle exit area (Ane), as it affects the visibility of the hot engine parts from the rear aspect. For constant design point thrust, IR radiance is studied from the boresight (ϕ = 0°, directly from the rear side) for various percentage changes in nozzle exit area (%ΔAne), in the 1.9-2.9 μm and 3-5 μm bands.

  10. Using a Medical Intranet of Things System to Prevent Bed Falls in an Acute Care Hospital: A Pilot Study.

    PubMed

    Balaguera, Henri U; Wise, Diana; Ng, Chun Yin; Tso, Han-Wen; Chiang, Wan-Lin; Hutchinson, Aimee M; Galvin, Tracy; Hilborne, Lee; Hoffman, Cathy; Huang, Chi-Cheng; Wang, C Jason

    2017-05-04

    Hospitalized patients in the United States experience falls at a rate of 2.6 to 17.1 per 1000 patient-days, with the majority occurring when a patient is moving to, from, and around the bed. Each fall with injury costs an average of US $14,000. The aim was to conduct a technology evaluation, including feasibility, usability, and user experience, of a medical sensor-based Intranet of things (IoT) system in facilitating nursing response to bed exits in an acute care hospital. Patients 18 years and older with a Morse fall score of 45 or greater were recruited from a 35-bed medical-surgical ward in a 317-bed Massachusetts teaching hospital. Eligible patients were recruited between August 4, 2015 and July 31, 2016. Participants received a sensor pad placed between the top of their mattress and bed sheet. The sensor pad was positioned to monitor movement from patients' shoulders to their thighs. The SensableCare System was evaluated for monitoring patient movement and delivering timely alerts to nursing staff via mobile devices when there appeared to be a bed-exit attempt. Sensor pad data were collected automatically from the system. The primary outcomes included number of falls, time to turn off bed-exit alerts, and the number of attempted bed-exit events. Data on patient falls were collected by clinical research assistants and confirmed with the unit nurse manager. Explanatory variables included room locations (zones 1-3), day of the week, nursing shift, and Morse Fall Scale (ie, positive fall history, positive secondary diagnosis, positive ambulatory aid, weak impaired gait/transfer, positive IV/saline lock, mentally forgets limitations). We also assessed user experience via nurse focus groups. Qualitative data regarding staff interactions with the system were collected during two focus groups with 25 total nurses, each lasting approximately 1.5 hours. A total of 91 patients used the system for 234.0 patient-days and experienced no bed falls during the study period. On average, patients were assisted/returned to bed 46 seconds after the alert system was triggered. Response times were longer during the overnight nursing shift versus day shift (P=.005), but were independent of the patient's location on the unit. Focus groups revealed that nurses found the system integrated well into the clinical nursing workflow and the alerts were helpful in patient monitoring. A medical IoT system can be integrated into the existing nursing workflow and may reduce patient bed fall risk in acute care hospitals, a high priority but an elusive patient safety challenge. By using an alerting system that sends notifications directly to nurses' mobile devices, nurses can equally respond to unassisted bed-exit attempts wherever patients are located on the ward. Further study, including a fully powered randomized controlled trial, is needed to assess effectiveness across hospital settings. ©Henri U Balaguera, Diana Wise, Chun Yin Ng, Han-Wen Tso, Wan-Lin Chiang, Aimee M Hutchinson, Tracy Galvin, Lee Hilborne, Cathy Hoffman, Chi-Cheng Huang, C Jason Wang. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 04.05.2017.

  11. Analysis of the trip costs of a traffic corridor with two entrances and one exit under car-following model

    NASA Astrophysics Data System (ADS)

    Tang, Tie-Qiao; Wang, Tao; Chen, Liang; Shang, Hua-Yan

    2017-11-01

    In this paper, we first define each commuter's first, second and third trip costs, and then apply the full velocity difference model and the VT-Micro model to explore each commuter's three trip costs and the system's corresponding total trip costs in a traffic corridor with two entrances and one exit. The numerical results show that one entrance has prominent effects on the commuter's three trip costs and the system's corresponding total trip cost and that the impacts are directly related to the commuter's departure interval at this entrance. The results can provide some suggestions for reducing the commuters' trip costs in a traffic corridor with two entrances and one exit.

  12. Selectivity analysis of an incoherent grating imaged in a photorefractive crystal

    NASA Astrophysics Data System (ADS)

    Tebaldi, Myrian; Forte, Gustavo; Bolognini, Nestor; Lasprilla A., Maria del Carmen

    2018-04-01

    In this work, the diffraction efficiency of a volume phase grating incoherently stored in a photorefractive BSO crystal is theoretically and experimentally analyzed. The results confirm the theoretical proposal based on the coupled wave theory adopting a new grating depth parameter associated to the write-in incoherent optical system. The selectivity behavior is governed by the exit pupil diameter of the imaging recording system that controls the depth of the tridimensional image distribution along the propagation direction. Two incoherent gratings are multiplexed in a single crystal and reconstructed without cross-talk.

  13. Think Exit at Entry

    ERIC Educational Resources Information Center

    O'Rourke, Tom; Satterfield, Coy E.

    2005-01-01

    This paper describes the "Think Exit at Entry" program that has become the guiding principle for the Georgia Department of Juvenile Justice (DJJ). The Georgia DJJ believes that the transition process begins the day the youth enters the system and continues well after release from the institution. Literature points the need for transition…

  14. 36 CFR 13.1312 - Climbing and walking on Exit Glacier.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false Climbing and walking on Exit Glacier. 13.1312 Section 13.1312 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Kenai Fjords National Park...

  15. Exit-Site Dressing and Infection in Peritoneal Dialysis: A Randomized Controlled Pilot Trial.

    PubMed

    Mushahar, Lily; Mei, Lim Wei; Yusuf, Wan Shaariah; Sivathasan, Sudhaharan; Kamaruddin, Norilah; Idzham, Nor Juliana Mohd

    2016-01-01

    ♦ Peritoneal dialysis (PD)-related infection is a common cause of catheter loss and the main reason for PD drop-out. Exit-site infection (ESI) is a pathway to developing tunnel infection and peritonitis, hence rigorous exit-site care has always been emphasized in PD therapy. The aim of this study was to evaluate the effect of exit-site dressing vs non-dressing on the rate of PD-related infection. ♦ A prospective randomized controlled study was conducted in prevalent PD patients at the Hospital Tuanku Jaafar Seremban, Negeri Sembilan, Malaysia, from April 2011 until April 2013. All patients were required to perform daily washing of the exit site with antibacterial soap during a shower. In the dressing group (n = 54), patients were required to clean their exit site using povidone-iodine after drying, followed by topical mupirocin antibiotic application to the exit site. The exit site was then covered with a sterile gauze dressing and the catheter immobilized with tape. In the non-dressing group (n = 54), patients were not required to do any further dressing after drying. They were only required to apply mupirocin cream to the exit site and then left the exit site uncovered. The catheter was immobilized with tape. The primary outcome was ESI. The secondary outcomes were evidence of tunnel infection or peritonitis. ♦ A total of 97 patients completed the study. There were a total of 12 ESI episodes: 4 episodes in 4 patients in the dressing group vs 8 episodes in 4 patients in the non-dressing group. This corresponds to 1 episode per 241.3 patient-months vs 1 episode per 111.1 patient-months in the dressing and non-dressing groups respectively. Median time to first ESI episode was shorter in the non-dressing than in the dressing group, but not significant (p = 0.25). The incidence of gram-positive ESI in both groups was similar. There were no gram-negative ESI in the non-dressing group compared with 2 in the dressing group. The peritonitis rate was 1 per 37.1 patient-month in the dressing group and 1 per 44.4 patient-months in the non-dressing group. Median time to first peritonitis episode was significantly shorter in the dressing group compared to non-dressing (p = 0.03). There was no impact of dressing disruptions in the occurrence of major PD catheter-related infection. ♦ Use of a non-dressing technique with only prophylactic topical mupirocin cream application is effective in preventing PD-related infection. The non-dressing technique is more cost-effective and convenient for PD patients, with fewer disposables. Copyright © 2016 International Society for Peritoneal Dialysis.

  16. Sliding Mode Control of a Thermal Mixing Process

    NASA Technical Reports Server (NTRS)

    Richter, Hanz; Figueroa, Fernando

    2004-01-01

    In this paper we consider the robust control of a thermal mixer using multivariable Sliding Mode Control (SMC). The mixer consists of a mixing chamber, hot and cold fluid valves, and an exit valve. The commanded positions of the three valves are the available control inputs, while the controlled variables are total mass flow rate, chamber pressure and the density of the mixture inside the chamber. Unsteady thermodynamics and linear valve models are used in deriving a 5th order nonlinear system with three inputs and three outputs, An SMC controller is designed to achieve robust output tracking in the presence of unknown energy losses between the chamber and the environment. The usefulness of the technique is illustrated with a simulation.

  17. Aeroassisted orbital maneuvering using Lyapunov optimal feedback control

    NASA Technical Reports Server (NTRS)

    Grantham, Walter J.; Lee, Byoung-Soo

    1987-01-01

    A Liapunov optimal feedback controller incorporating a preferred direction of motion at each state of the system which is opposite to the gradient of a specified descent function is developed for aeroassisted orbital transfer from high-earth orbit to LEO. The performances of the Liapunov controller and a calculus-of-variations open-loop minimum-fuel controller, both of which are based on the 1962 U.S. Standard Atmosphere, are simulated using both the 1962 U.S. Standard Atmosphere and an atmosphere corresponding to the STS-6 Space Shuttle flight. In the STS-6 atmosphere, the calculus-of-variations open-loop controller fails to exit the atmosphere, while the Liapunov controller achieves the optimal minimum-fuel conditions, despite the + or - 40 percent fluctuations in the STS-6 atmosphere.

  18. Numerical investigations in the backflow region of a vacuum plume

    NASA Technical Reports Server (NTRS)

    Liaw, Goang-Shin

    1992-01-01

    The objective of this research is to numerically simulate the vacuum plume flow field in the backflow region of a low thrust nozzle exit. In space applications, the low thrust nozzles are used as a propulsion device to control the vehicle attitude, or to maneuver the vehicle flight trajectory. When the spacecraft is deployed in the orbit or cruising in a planetary mission, the vacuum plume is created behind the nozzle exit (so called backflow region), by the exhausting gas of the propulsion system or by venting internal gas to the extremely low density ambient. The low density vacuum plume flow regions cover the continuum, transitional and free molecular flow regimes, which were characterized by the Knudsen number K(sub n), K(sub n) = lambda(sub m)/L where lambda(sub m) is the mean free path of the gas molecules and L is the characteristic length of the flow field. The transitional regime is defined by 0.01 is less than or equal to K(sub n) is less than or equal to 10. The conventional Navier-Stokes equations are valid only in the flow region close to the nozzle exit since the validity of the Navier-Stokes equations fails asymptotically as the Knudsen number increases. The vacuum plume characteristics prediction is primarily a problem of transitional aerodynamics.

  19. Flights between a neighborhoods of unstable libration points of Sun-Earth system

    NASA Astrophysics Data System (ADS)

    Surkova, Valerya; Shmyrov, Vasily

    2018-05-01

    In this paper we study the problem of constructing impulse flights between neighborhoods of unstable collinear libration points of the Sun-Earth system [1]. Such maneuvering in near-Earth space may prove to be in demand in modern space navigation. For example, such a maneuvering was done by the space vehicle GENESIS. Three test points are chosen for the implementation of the impulse control, in order to move to a neighborhood of the libration point L2. It is shown that the earlier on the exit from the vicinity of the libration point L1 impulse control was realized, the sooner the neighborhood L2 was achieved. Separated from this problem, the problem of optimal control in the neighborhood of L2 was considered and a form of stabilizing control is presented.

  20. 77. Deputy commander's launch control console, fire control panel missing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    77. Deputy commander's launch control console, fire control panel missing at right, south side - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  1. Software design of control system of CCD side-scatter lidar

    NASA Astrophysics Data System (ADS)

    Kuang, Zhiqiang; Liu, Dong; Deng, Qian; Zhang, Zhanye; Wang, Zhenzhu; Yu, Siqi; Tao, Zongming; Xie, Chenbo; Wang, Yingjian

    2018-03-01

    Because of the existence of blind zone and transition zone, the application of backscattering lidar in near-ground is limited. The side-scatter lidar equipped with the Charge Coupled Devices (CCD) can separate the transmitting and receiving devices to avoid the impact of the geometric factors which is exited in the backscattering lidar and, detect the more precise near-ground aerosol signals continuously. Theories of CCD side-scatter lidar and the design of control system are introduced. The visible control of laser and CCD and automatic data processing method of the side-scatter lidar are developed by using the software of Visual C #. The results which are compared with the calibration of the atmospheric aerosol lidar data show that signals from the CCD side- scatter lidar are convincible.

  2. An alternative way of understanding exit, voice and loyalty: the case of informal payments for health care in Israel.

    PubMed

    Cohen, Nissim; Filc, Dani

    2017-01-01

    This study examines Hirschman's model of exit, voice and loyalty with regard to informal payments in the Israeli healthcare system. Based on a national survey, we investigate the extent of "black" payments, its characteristics and its correlated factors. We find that informal payments do exist in Israel-although it seems that there has been a decline in the phenomenon. Contrary to the literature, we find no relationship between the option of voice or dissatisfaction with healthcare services and informal payments. However, we do find a negative correlation between trust and the use of such payments. This finding is consistent with Hirschman's insight that a lack of loyalty may lead people to strategies of exit. We suggest that given the fact that health care in Israel is a public service, the exit option may actually be a quasi-exit behavior. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Demonstration of Land and Hold Short Technology at the Dallas-Fort Worth International Airport

    NASA Technical Reports Server (NTRS)

    Hyer, Paul V.; Jones, Denise R. (Technical Monitor)

    2002-01-01

    A guidance system for assisting in Land and Hold Short operations was developed and then tested at the Dallas-Fort Worth International Airport. This system displays deceleration advisory information on a head-up display (HUD) in front of the airline pilot during landing. The display includes runway edges, a trend vector, deceleration advisory, locations of the hold line and of the selected exit, and alphanumeric information about the progress of the aircraft. Deceleration guidance is provided to the hold short line or to a pilot selected exit prior to this line. Logic is provided to switch the display automatically to the next available exit. The report includes descriptions of the algorithms utilized in the displays, and a report on the techniques of HUD alignment, and results.

  4. Combined electrophoretic-separation and electrospray method and system

    DOEpatents

    Smith, Richard D.; Olivares, Jose A.

    1989-01-01

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary zone electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit.

  5. 40 CFR 63.1409 - Heat exchange system provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... locations where the cooling water enters and exits each heat exchanger or any combination of heat exchangers.... (iii) For samples taken at the entrance and exit of each heat exchanger or any combination of heat exchangers, the entrance is the point at which the cooling water enters the individual heat exchanger or...

  6. 40 CFR 63.1409 - Heat exchange system provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and exits each heat exchanger or any combination of heat exchangers. (i) For samples taken at the... entrance and exit of each heat exchanger or any combination of heat exchangers, the entrance is the point at which the cooling water enters the individual heat exchanger or group of heat exchangers, and the...

  7. 40 CFR 63.1409 - Heat exchange system provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and exits each heat exchanger or any combination of heat exchangers. (i) For samples taken at the... entrance and exit of each heat exchanger or any combination of heat exchangers, the entrance is the point at which the cooling water enters the individual heat exchanger or group of heat exchangers, and the...

  8. 36 CFR 1234.34 - When may NARA conduct an inspection of a records storage facility?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....) Required. Entrances/Exits: X-ray & magnetometer at public entrances Recommended. Require x-ray screening of... design requirements, (e.g. fire detection, fire suppression systems, etc.) Entrances/Exits X-Ray and... would focus on tenant agencies, public interface, and feasibility. Required for Level V. Require X-Ray...

  9. 36 CFR 1234.34 - When may NARA conduct an inspection of a records storage facility?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....) Required. Entrances/Exits: X-ray & magnetometer at public entrances Recommended. Require x-ray screening of... design requirements, (e.g. fire detection, fire suppression systems, etc.) Entrances/Exits X-Ray and... would focus on tenant agencies, public interface, and feasibility. Required for Level V. Require X-Ray...

  10. Aircraft and avionic related research required to develop an effective high-speed runway exit system

    NASA Technical Reports Server (NTRS)

    Schoen, M. L.; Hosford, J. E.; Graham, J. M., Jr.; Preston, O. W.; Frankel, R. S.; Erickson, J. B.

    1979-01-01

    Research was conducted to increase airport capacity by studying the feasibility of the longitudinal separation between aircraft sequences on final approach. The multidisciplinary factors which include the utility of high speed exits for efficient runway operations were described along with recommendations and highlights of these studies.

  11. 40 CFR 63.1409 - Heat exchange system provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... locations where the cooling water enters and exits each heat exchanger or any combination of heat exchangers.... (iii) For samples taken at the entrance and exit of each heat exchanger or any combination of heat exchangers, the entrance is the point at which the cooling water enters the individual heat exchanger or...

  12. Use of Blade Lean in Turbomachinery Redesign

    NASA Technical Reports Server (NTRS)

    Moore, John; Moore, Joan G.; Lupi, Alex

    1993-01-01

    Blade lean is used to improve the uniformity of exit flow distributions from turbomachinery blading. In turbines, it has been used to control secondary flows by tailoring blade turning to reduce flow overturning and underturning and to create more uniform loss distributions from hub to shroud. In the present study, the Pump Consortium centrifugal impeller has been redesigned using blade lean. The flow at the exit of the baseline impeller had large blade-to-blade variations, creating a highly unsteady flow for the downstream diffuser. Blade lean is used to redesign the flow to move the high loss fluid from the suction side to the hub, significantly reducing blade-toblade variations at the exit.

  13. Method and apparatus for strip casting

    DOEpatents

    Follstaedt, D.W.; Powell, J.C.; Sussman, R.C.; Williams, R.S.

    1991-11-12

    Casting nozzles will provide improved flow conditions with the parameters controlled according to the present invention. The gap relationships between the nozzle slot and exit orifice must be controlled in combination with converging exit passageway to provide a smooth flow without shearing and turbulence in the stream. The nozzle lips are also rounded to improve flow and increase refractory life of the lips of the nozzle. The tundish walls are tapered to provide improve flow for supplying the melt to the nozzle. The nozzle is located about 45[degree] below top dead center for optimum conditions. 2 figures.

  14. An Overview of the NASA F-18 High Alpha Research Vehicle

    NASA Technical Reports Server (NTRS)

    Bowers, Albion H.; Pahle, Joseph W.; Wilson, R. Joseph; Flick, Bradley C.; Rood, Richard L.

    1996-01-01

    This paper gives an overview of the NASA F-18 High Alpha Research Vehicle. The three flight phases of the program are introduced, along with the specific goals and data examples taken during each phase. The aircraft configuration and systems needed to perform the disciplinary and inter-disciplinary research are discussed. The specific disciplines involved with the flight research are introduced, including aerodynamics, controls, propulsion, systems, and structures. Decisions that were made early in the planning of the aircraft project and the results of those decisions are briefly discussed. Each of the three flight phases corresponds to a particular aircraft configuration, and the research dictated the configuration to be flown. The first phase gathered data with the baseline F-18 configuration. The second phase was the thrust-vectoring phase. The third phase used a modified forebody with deployable nose strakes. Aircraft systems supporting these flights included extensive instrumentation systems, integrated research flight controls using flight control hardware and corresponding software, analog interface boxes to control forebody strakes, a thrust-vectoring system using external post-exit vanes around axisymmetric nozzles, a forebody vortex control system with strakes, and backup systems using battery-powered emergency systems and a spin recovery parachute.

  15. Numerical analysis of exhaust jet secondary combustion in hypersonic flow field

    NASA Astrophysics Data System (ADS)

    Yang, Tian-Peng; Wang, Jiang-Feng; Zhao, Fa-Ming; Fan, Xiao-Feng; Wang, Yu-Han

    2018-05-01

    The interaction effect between jet and control surface in supersonic and hypersonic flow is one of the key problems for advanced flight control system. The flow properties of exhaust jet secondary combustion in a hypersonic compression ramp flow field were studied numerically by solving the Navier-Stokes equations with multi-species and combustion reaction effects. The analysis was focused on the flow field structure and the force amplification factor under different jet conditions. Numerical results show that a series of different secondary combustion makes the flow field structure change regularly, and the temperature increases rapidly near the jet exit.

  16. Asymptotic problems for stochastic partial differential equations

    NASA Astrophysics Data System (ADS)

    Salins, Michael

    Stochastic partial differential equations (SPDEs) can be used to model systems in a wide variety of fields including physics, chemistry, and engineering. The main SPDEs of interest in this dissertation are the semilinear stochastic wave equations which model the movement of a material with constant mass density that is exposed to both determinstic and random forcing. Cerrai and Freidlin have shown that on fixed time intervals, as the mass density of the material approaches zero, the solutions of the stochastic wave equation converge uniformly to the solutions of a stochastic heat equation, in probability. This is called the Smoluchowski-Kramers approximation. In Chapter 2, we investigate some of the multi-scale behaviors that these wave equations exhibit. In particular, we show that the Freidlin-Wentzell exit place and exit time asymptotics for the stochastic wave equation in the small noise regime can be approximated by the exit place and exit time asymptotics for the stochastic heat equation. We prove that the exit time and exit place asymptotics are characterized by quantities called quasipotentials and we prove that the quasipotentials converge. We then investigate the special case where the equation has a gradient structure and show that we can explicitly solve for the quasipotentials, and that the quasipotentials for the heat equation and wave equation are equal. In Chapter 3, we study the Smoluchowski-Kramers approximation in the case where the material is electrically charged and exposed to a magnetic field. Interestingly, if the system is frictionless, then the Smoluchowski-Kramers approximation does not hold. We prove that the Smoluchowski-Kramers approximation is valid for systems exposed to both a magnetic field and friction. Notably, we prove that the solutions to the second-order equations converge to the solutions of the first-order equation in an Lp sense. This strengthens previous results where convergence was proved in probability.

  17. 86. Shock absorber, top of launch control center, southeast corner ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    86. Shock absorber, top of launch control center, southeast corner - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  18. 69. Commander's launch control console, east end, plexiglass shield up ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    69. Commander's launch control console, east end, plexiglass shield up - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  19. 13. Sewage treatment lagoon, drainage control at center left, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Sewage treatment lagoon, drainage control at center left, looking south - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  20. Anode protection system for shutdown of solid oxide fuel cell system

    DOEpatents

    Li, Bob X; Grieves, Malcolm J; Kelly, Sean M

    2014-12-30

    An Anode Protection Systems for a SOFC system, having a Reductant Supply and safety subsystem, a SOFC anode protection subsystem, and a Post Combustion and slip stream control subsystem. The Reductant Supply and safety subsystem includes means for generating a reducing gas or vapor to prevent re-oxidation of the Ni in the anode layer during the course of shut down of the SOFC stack. The underlying ammonia or hydrogen based material used to generate a reducing gas or vapor to prevent the re-oxidation of the Ni can be in either a solid or liquid stored inside a portable container. The SOFC anode protection subsystem provides an internal pressure of 0.2 to 10 kPa to prevent air from entering into the SOFC system. The Post Combustion and slip stream control subsystem provides a catalyst converter configured to treat any residual reducing gas in the slip stream gas exiting from SOFC stack.

  1. Correlation Between Glycemic Control and the Incidence of Peritoneal and Catheter Tunnel and Exit-Site Infections in Diabetic Patients Undergoing Peritoneal Dialysis

    PubMed Central

    Rodríguez-Carmona, Ana; Pérez-Fontán, Miguel; López-Muñiz, Andrés; Ferreiro-Hermida, Tamara; García-Falcón, Teresa

    2014-01-01

    ♦ Background: Diabetes mellitus, especially if complicated by poor glycemic control, portends an increased risk of infection. The significance of this association in the case of diabetic patients undergoing peritoneal dialysis (PD) has not been assessed. ♦ Methods: Using a retrospective observational design, we analyzed the association between glycemic control at the start of PD (estimated from glycosylated hemoglobin levels) and the risk of peritoneal and catheter tunnel and exit-site infections during follow-up in 183 incident patients on PD. We used the median value of glycosylated hemoglobin to classify patients into good (group A) or poor (group B) glycemic control groups. We applied multivariate strategies of analysis to control for other potential predictors of PD-related infection. ♦ Results: Groups A and B differed significantly in age, dialysis vintage, use of insulin, and rate of Staphylococcus aureus carriage. Neither the incidence (0.60 episodes in group A vs 0.56 episodes in group B per patient-year) nor the time to a first peritoneal infection (median: 42 months vs 38 months) differed significantly between the study groups. In contrast, group B had a significantly higher incidence of catheter tunnel and exit-site infections (0.23 episodes vs 0.12 episodes per patient-year) and shorter time to a first infection episode (64 months vs 76 months, p = 0.004). The difference persisted in multivariate analysis (adjusted hazard ratio: 2.65; 95% confidence interval: 1.13 to 6.05; p = 0.013). We observed no differences between the study groups in the spectrum of causative organisms or in the outcomes of PD-related infections. ♦ Conclusions: Poor glycemic control is a consistent predictor of subsequent risk of catheter tunnel and exit-site infection, but not of peritoneal infection, among diabetic patients starting PD therapy. PMID:23818005

  2. Comparison of native versus nonnative English-speaking nurses on critical thinking assessments at entry and exit.

    PubMed

    Whitehead, Tanya D

    2006-01-01

    Diversity of language among healthcare employees and nursing students is growing as diversity increases among the general population. Institutions have begun to develop systems to accommodate diversity and to assimilate workers. One barrier to nonnative English-speaking nurse hires may be posed by readiness for the licensure exam and the critical thinking assessments that are now an expected outcome of nursing programs, and act as a gatekeeper to graduation and to employment. To assist in preparing for high-stakes testing, the Assessment Technologies Institute Critical Thinking Assessment was developed in compliance with credentialing bodies' educational outcomes criteria. This pilot study of 209 nursing students was designed to reveal any possible language bias that might act as a barrier to nonnative English speakers. Nursing students were entered as whole classes to the study to control for selection bias. A sample representative of national nursing enrollment was obtained from 21 universities, with 192 (92%) native English-speaking students and 17 (8%) nonnative English speakers participating in the study. All students were given the Assessment Technologies Institute Critical Thinking Assessment at entry and exit to their nursing program. Average scores on entry were 66% for nonnative speakers and 72% for native speakers. At exit, the nonnative speakers had closed the gap in academic outcomes. They had an average score of 72% compared to 73% for native speakers. The study found that the slight differences between the native and nonnative speakers on 2 exit outcome measures-National Council licensure examination (NCLEX-RN) pass rates and Critical Thinking Assessment-were not statistically significant, demonstrating that nonnative English speakers achieved parity with native English-speaking peers on the Critical Thinking Assessment tool, which is often believed to be related to employment readiness.

  3. Bone Morphogenetic Protein Regulation of Enteric Neuronal Phenotypic Diversity: Relationship to Timing of Cell Cycle Exit

    PubMed Central

    Chalazonitis, Alcmène; Pham, Tuan.D.; Li, Zhishan; Roman, Daniel; Guha, Udayan; Gomes, William; Kan, Lixin; Kessler, John A.; Gershon, Michael D.

    2008-01-01

    The effects of bone morphogenetic protein (BMP) signaling on enteric neuron development were examined in transgenic mice over expressing either the BMP inhibitor, noggin, or BMP4 under control of the neuron specific enolase (NSE) promoter. Noggin antagonism of BMP signaling increased total numbers of enteric neurons and those of subpopulations derived from precursors that exit the cell cycle early in neurogenesis (serotonin, calretinin, calbindin). In contrast, noggin overexpression decreased numbers of neurons derived from precursors that exit the cell cycle late (γ-aminobutyric acid, tyrosine hydroxylase [TH], dopamine transporter, calcitonin gene related peptide, TrkC). Numbers of TH- and TrkC-expressing neurons were increased by overexpression of BMP4. These observations are consistent with the idea that phenotypic expression in the enteric nervous system (ENS) is determined, in part, by the number of proliferative divisions neuronal precursors undergo before their terminal mitosis. BMP signaling may thus regulate enteric neuronal phenotypic diversity by promoting the exit of precursors from the cell cycle. BMP2 increased the numbers of TH- and TrkC-expressing neurons developing in vitro from immunoselected enteric crest-derived precursors; BMP signaling may thus also specify or promote the development of dopaminergic TrkC/NT-3-dependent neurons. The developmental defects in the ENS of noggin overexpressing mice caused a relatively mild disturbance of motility (irregular rapid transit and increased stool frequency, weight, and water content). Although the function of the gut thus displays a remarkable tolerance for ENS defects, subtle functional abnormalities in motility or secretion may arise when ENS defects short of aganglionosis occur during development. PMID:18537141

  4. Interactions between pool geometry and hydraulics

    USGS Publications Warehouse

    Thompson, Douglas M.; Nelson, Jonathan M.; Wohl, Ellen E.

    1998-01-01

    An experimental and computational research approach was used to determine interactions between pool geometry and hydraulics. A 20-m-long, 1.8-m-wide flume was used to investigate the effect of four different geometric aspects of pool shape on flow velocity. Plywood sections were used to systematically alter constriction width, pool depth, pool length, and pool exit-slope gradient, each at two separate levels. Using the resulting 16 unique geometries with measured pool velocities in four-way factorial analyses produced an empirical assessment of the role of the four geometric aspects on the pool flow patterns and hence the stability of the pool. To complement the conclusions of these analyses, a two-dimensional computational flow model was used to investigate the relationships between pool geometry and flow patterns over a wider range of conditions. Both experimental and computational results show that constriction and depth effects dominate in the jet section of the pool and that pool length exhibits an increasing effect within the recirculating-eddy system. The pool exit slope appears to force flow reattachment. Pool length controls recirculating-eddy length and vena contracta strength. In turn, the vena contracta and recirculating eddy control velocities throughout the pool.

  5. Nonimaging light concentrator with uniform irradiance

    DOEpatents

    Winston, Roland; Gee, Randy C.

    2003-04-01

    A nonimaging light concentrator system including a primary collector of light, an optical mixer disposed near the focal zone for collecting light from the primary collector, the optical mixer having a transparent entrance aperture, an internally reflective housing for substantially total internal reflection of light, a transparent exit aperture and an array of photovoltaic cells disposed near the transparent exit aperture.

  6. High School Exit Exams: The Attitudes and Perceptions of Superintendents

    ERIC Educational Resources Information Center

    Keenan, Robert A.

    2010-01-01

    In the U. S. 25 states operate from an assessment based frame of reference that includes some form of high school exit examination. Enhancements for existing assessment and accountability systems need to be explored according to the findings of Elizabeth Towles. The problem addressed in this study was that little research had been conducted to…

  7. 29 CFR 1910.36 - Design and construction requirements for exit routes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a... route must be a permanent part of the workplace. (2) An exit must be separated by fire resistant...

  8. 29 CFR 1910.36 - Design and construction requirements for exit routes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a... route must be a permanent part of the workplace. (2) An exit must be separated by fire resistant...

  9. Causal Factors Attributed to Student Success on the California High School Exit Examination

    ERIC Educational Resources Information Center

    Rose, Nikita A.

    2011-01-01

    American students are failing to demonstrate expected competency on basic skills taught in schools. The educational system needs a major overhaul to address declines in scholarly engagement. The State Board of Education (SBE) designed the California High School Exit Exam (CAHSEE) to give some merit to the high school diploma. Minorities and…

  10. Radiation collimator and systems incorporating same

    DOEpatents

    Norman, Daren R [Idaho Falls, ID; Yoon, Woo Y [Idaho Falls, ID; Jones, James L [Idaho Falls, ID; Haskell, Kevin J [Idaho Falls, ID; Bennett, Brion D [Idaho Falls, ID; Tschaggeny, Charles W [Woods Cross, UT; Jones, Warren F [Idaho Falls, ID

    2011-09-13

    A collimator including a housing having disposed therein a shield element surrounding a converter core in which a photon beam is generated from electrons emanating from a linear accelerator. A beam channeler longitudinally adjacent the shield element has a beam aperture therethrough coaxially aligned with, and of the same diameter as, an exit bore of the converter core. A larger entry bore in the converter core is coaxial with, and longitudinally separated from, the exit bore thereof. Systems incorporating the collimator are also disclosed.

  11. Negative ion source with low temperature transverse divergence optical system

    DOEpatents

    Whealton, John H.; Stirling, William L.

    1986-01-01

    A negative ion source is provided which has extremely low transverse divergence as a result of a unique ion focusing system in which the focal line of an ion beam emanating from an elongated, concave converter surface is outside of the ion exit slit of the source and the path of the exiting ions. The beam source operates with a minimum ion temperature which makes possible a sharply focused (extremely low transverse divergence) ribbon like negative ion beam.

  12. Negative ion source with low temperature transverse divergence optical system

    DOEpatents

    Whealton, J.H.; Stirling, W.L.

    1985-03-04

    A negative ion source is provided which has extremely low transverse divergence as a result of a unique ion focusing system in which the focal line of an ion beam emanating from an elongated, concave converter surface is outside of the ion exit slit of the source and the path of the exiting ions. The beam source operates with a minimum ion temperature which makes possible a sharply focused (extremely low transverse divergence) ribbon like negative ion beam.

  13. 83. Shock absorber attaching "egg" to the launch control center, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    83. Shock absorber attaching "egg" to the launch control center, southwest corner - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  14. Two-stage optics - High-acuity performance from low-acuity optical systems

    NASA Technical Reports Server (NTRS)

    Meinel, Aden B.; Meinel, Marjorie P.

    1992-01-01

    The concept of two-stage optics, developed under a program to enhance the performance, lower the cost, and increase the reliability of the 20-m Large Deployable Telescope, is examined. The concept permits the large primary mirror to remain as deployed or as space-assembled, with phasing and subsequent control of the system done by a small fully assembled optical active element placed at an exit pupil. The technique is being applied to correction of the fabrication/testing error in the Hubble Space Telescope primary mirror. The advantages offered by this concept for very large space telescopes are discussed.

  15. Combined electrophoretic-separation and electrospray method and system

    DOEpatents

    Smith, R.D.; Olivares, J.A.

    1989-06-27

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary zone electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., [+-]2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit. 10 figs.

  16. Accuracy of a radiofrequency identification (RFID) badge system to monitor hand hygiene behavior during routine clinical activities.

    PubMed

    Pineles, Lisa L; Morgan, Daniel J; Limper, Heather M; Weber, Stephen G; Thom, Kerri A; Perencevich, Eli N; Harris, Anthony D; Landon, Emily

    2014-02-01

    Hand hygiene (HH) is a critical part of infection prevention in health care settings. Hospitals around the world continuously struggle to improve health care personnel (HCP) HH compliance. The current gold standard for monitoring compliance is direct observation; however, this method is time-consuming and costly. One emerging area of interest involves automated systems for monitoring HH behavior such as radiofrequency identification (RFID) tracking systems. To assess the accuracy of a commercially available RFID system in detecting HCP HH behavior, we compared direct observation with data collected by the RFID system in a simulated validation setting and to a real-life clinical setting over 2 hospitals. A total of 1,554 HH events was observed. Accuracy for identifying HH events was high in the simulated validation setting (88.5%) but relatively low in the real-life clinical setting (52.4%). This difference was significant (P < .01). Accuracy for detecting HCP movement into and out of patient rooms was also high in the simulated setting but not in the real-life clinical setting (100% on entry and exit in simulated setting vs 54.3% entry and 49.5% exit in real-life clinical setting, P < .01). In this validation study of an RFID system, almost half of the HH events were missed. More research is necessary to further develop these systems and improve accuracy prior to widespread adoption. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  17. Evaluation of six TPS algorithms in computing entrance and exit doses.

    PubMed

    Tan, Yun I; Metwaly, Mohamed; Glegg, Martin; Baggarley, Shaun; Elliott, Alex

    2014-05-08

    Entrance and exit doses are commonly measured in in vivo dosimetry for comparison with expected values, usually generated by the treatment planning system (TPS), to verify accuracy of treatment delivery. This report aims to evaluate the accuracy of six TPS algorithms in computing entrance and exit doses for a 6 MV beam. The algorithms tested were: pencil beam convolution (Eclipse PBC), analytical anisotropic algorithm (Eclipse AAA), AcurosXB (Eclipse AXB), FFT convolution (XiO Convolution), multigrid superposition (XiO Superposition), and Monte Carlo photon (Monaco MC). Measurements with ionization chamber (IC) and diode detector in water phantoms were used as a reference. Comparisons were done in terms of central axis point dose, 1D relative profiles, and 2D absolute gamma analysis. Entrance doses computed by all TPS algorithms agreed to within 2% of the measured values. Exit doses computed by XiO Convolution, XiO Superposition, Eclipse AXB, and Monaco MC agreed with the IC measured doses to within 2%-3%. Meanwhile, Eclipse PBC and Eclipse AAA computed exit doses were higher than the IC measured doses by up to 5.3% and 4.8%, respectively. Both algorithms assume that full backscatter exists even at the exit level, leading to an overestimation of exit doses. Despite good agreements at the central axis for Eclipse AXB and Monaco MC, 1D relative comparisons showed profiles mismatched at depths beyond 11.5 cm. Overall, the 2D absolute gamma (3%/3 mm) pass rates were better for Monaco MC, while Eclipse AXB failed mostly at the outer 20% of the field area. The findings of this study serve as a useful baseline for the implementation of entrance and exit in vivo dosimetry in clinical departments utilizing any of these six common TPS algorithms for reference comparison.

  18. Amuchina 10% solution, safe antiseptic for preventing infections of exit-site of Tenckhoff catheters, in the pediatric population of a dialysis program.

    PubMed

    Mendoza-Guevara, L; Castro-Vazquez, F; Aguilar-Kitsu, A; Morales-Nava, A; Rodriguez-Leyva, F; Sanchez-Barbosa, J L

    2007-01-01

    Although, decreasing in incidence with the disconnection systems, the first complication is still peritonitis in patients with chronic renal failure and the second is infection of Tenckhoff catheter exit-site. All efforts made to diminish the frequency of exit-site infection lower the possibility of peritonitis. The pediatric population is well-known to have a major risk of infectious complications, and making easy and safe the care of the exit-site will prevent the peritonitis that follows. The aim of the study was to evaluate the efficacy of the Amuchina 10% solution vs. pH neutral soap in children with chronic renal failure, on preventing exit-site infection. There were 60 patients who were assigned randomly to one of two groups. One group used Amuchina 10% solution for the daily cleaning of the exit-site, and the other used pH neutral soap, with 14 months of follow-up. Before the study they have to be free of infection for at least 30 days. All were taught by the same nurse how to clean their exit-site. Groups were almost identical in years, sex, and time on dialysis. We had nine infections in the soap group and none in the Amuchina 10% solution group, with an OR: 17 (p = 0.004). From these nine infections, the bacteria isolated were: 4 (13%) were caused by Pseudomona aeruginosa, 1 (3.3%) by Staphylococcus aureus, coagulase-positive staphylococci in 2 (6.6%) and Serratia marcensens in 1 (3.3%). In conclusion, Amuchina 10% solution is effective in preventing infection on the exit-site, without any secondary topical reaction.

  19. Conversion to lacosamide monotherapy in the treatment of focal epilepsy: Results from a historical-controlled, multicenter, double-blind study

    PubMed Central

    Wechsler, Robert T; Li, George; French, Jacqueline; O'Brien, Terence J; D'Cruz, O'Neill; Williams, Paulette; Goodson, Robin; Brock, Melissa

    2014-01-01

    Objective To evaluate the efficacy and safety of conversion to lacosamide 400 mg/day monotherapy in adults with focal epilepsy. Methods This historical-controlled, double-blind study (NCT00520741) enrolled patients aged 16–70 years on stable doses of 1–2 antiepileptic drugs (AEDs) and experiencing 2–40 partial-onset seizures per 28 days during the 8-week prospective Baseline. Patients were randomized to lacosamide 400 or 300 mg/day (3:1 ratio), starting at 200 mg/day and titrated over 3 weeks to randomized dose. Patients then withdrew background AEDs over 6 weeks and entered a 10-week Monotherapy Phase. The primary assessment was the Kaplan-Meier–predicted percentage of patients on 400 mg/day in the full analysis set (FAS) meeting ≥1 predefined seizure-related exit criterion by day 112, compared with the historical-control threshold (65.3%). Results Four hundred twenty-five patients were enrolled and were eligible for safety analyses (400 mg/day, n = 319; 300 mg/day, n = 106). A total of 271 (63.8%) of 425 patients completed the Lacosamide Maintenance Phase (combined AED Withdrawal and Monotherapy Phases). Among 284 patients in the 400 mg/day group in the FAS, 82 (28.9%) met ≥1 exit criterion; the Kaplan-Meier–predicted exit percentage at day 112 for 400 mg/day (30.0%; 95% confidence interval [CI] 24.6–35.5%) was lower than the historical control. When exit events, withdrawal due to treatment-emergent adverse events (TEAEs), and withdrawal due to lack of efficacy were summed (n = 90), the predicted exit percentage (32.3%; 95% CI 26.8–37.8%) was also lower than the historical control. Most patients receiving 400 mg/day reported some improvement on the Clinical Global Impression of Change (75.4%) and Patient Global Impression of Change (74.3%). Overall, the most common (>10%) TEAEs were dizziness (24.0%), headache (14.4%), nausea (13.4%), convulsion (11.5%), somnolence (10.4%), and fatigue (10.1%); most (74.1%) were mild-to-moderate in intensity. Seventy-two patients (16.9%) discontinued due to TEAEs. Seventeen patients (4%, all receiving 400 mg/day) experienced serious AEs. Significance Lacosamide 400 mg/day monotherapy was effective, with a favorable safety profile in patients with focal epilepsy. PMID:24915838

  20. Conversion to lacosamide monotherapy in the treatment of focal epilepsy: results from a historical-controlled, multicenter, double-blind study.

    PubMed

    Wechsler, Robert T; Li, George; French, Jacqueline; O'Brien, Terence J; D'Cruz, O'Neill; Williams, Paulette; Goodson, Robin; Brock, Melissa

    2014-07-01

    To evaluate the efficacy and safety of conversion to lacosamide 400 mg/day monotherapy in adults with focal epilepsy. This historical-controlled, double-blind study (NCT00520741) enrolled patients aged 16-70 years on stable doses of 1-2 antiepileptic drugs (AEDs) and experiencing 2-40 partial-onset seizures per 28 days during the 8-week prospective Baseline. Patients were randomized to lacosamide 400 or 300 mg/day (3:1 ratio), starting at 200 mg/day and titrated over 3 weeks to randomized dose. Patients then withdrew background AEDs over 6 weeks and entered a 10-week Monotherapy Phase. The primary assessment was the Kaplan-Meier-predicted percentage of patients on 400 mg/day in the full analysis set (FAS) meeting ≥ 1 predefined seizure-related exit criterion by day 112, compared with the historical-control threshold (65.3%). Four hundred twenty-five patients were enrolled and were eligible for safety analyses (400 mg/day, n = 319; 300 mg/day, n = 106). A total of 271 (63.8%) of 425 patients completed the Lacosamide Maintenance Phase (combined AED Withdrawal and Monotherapy Phases). Among 284 patients in the 400 mg/day group in the FAS, 82 (28.9%) met ≥ 1 exit criterion; the Kaplan-Meier-predicted exit percentage at day 112 for 400 mg/day (30.0%; 95% confidence interval [CI] 24.6-35.5%) was lower than the historical control. When exit events, withdrawal due to treatment-emergent adverse events (TEAEs), and withdrawal due to lack of efficacy were summed (n = 90), the predicted exit percentage (32.3%; 95% CI 26.8-37.8%) was also lower than the historical control. Most patients receiving 400 mg/day reported some improvement on the Clinical Global Impression of Change (75.4%) and Patient Global Impression of Change (74.3%). Overall, the most common (>10%) TEAEs were dizziness (24.0%), headache (14.4%), nausea (13.4%), convulsion (11.5%), somnolence (10.4%), and fatigue (10.1%); most (74.1%) were mild-to-moderate in intensity. Seventy-two patients (16.9%) discontinued due to TEAEs. Seventeen patients (4%, all receiving 400 mg/day) experienced serious AEs. Lacosamide 400 mg/day monotherapy was effective, with a favorable safety profile in patients with focal epilepsy. Wiley Periodicals, Inc. © 2014 International League Against Epilepsy.

  1. 72. View of launch control center towards the blast door ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    72. View of launch control center towards the blast door and west, seat empty - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  2. 70. Commander's launch control console, plexiglass shield down, looking southeast, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    70. Commander's launch control console, plexiglass shield down, looking southeast, filing cabinet in corner - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  3. 57. Interior of launch control center, crew in B52 seats, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    57. Interior of launch control center, crew in B-52 seats, looking east - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  4. Controlled overspray spray nozzle

    NASA Technical Reports Server (NTRS)

    Prasthofer, W. P. (Inventor)

    1981-01-01

    A spray system for a multi-ingredient ablative material wherein a nozzle A is utilized for suppressing overspray is described. The nozzle includes a cyclindrical inlet which converges to a restricted throat. A curved juncture between the cylindrical inlet and the convergent portion affords unrestricted and uninterrupted flow of the ablative material. A divergent bell-shaped chamber and adjustable nozzle exit B is utilized which provides a highly effective spray pattern in suppressing overspray to an acceptable level and producing a homogeneous jet of material that adheres well to the substrate.

  5. Association Between Health Plan Exit From Medicaid Managed Care and Quality of Care, 2006-2014

    PubMed Central

    Schpero, William L.; Schlesinger, Mark J.; Trivedi, Amal N.

    2017-01-01

    Importance State Medicaid programs have increasingly contracted with insurers to provide medical care services for enrollees (Medicaid managed care plans). Insurers that provide these plans can exit Medicaid programs each year, with unclear effects on quality of care and health care experiences. Objective To determine the frequency and interstate variation of health plan exit from Medicaid managed care and evaluate the relationship between health plan exit and market-level quality. Design, Setting, and Participants Retrospective cohort of all comprehensive Medicaid managed care plans (N = 390) during the interval 2006-2014. Exposures Plan exit, defined as the withdrawal of a managed care plan from a state’s Medicaid program. Main Outcomes and Measures Eight measures from the Healthcare Effectiveness Data and Information Set were used to construct 3 composite indicators of quality (preventive care, chronic disease care management, and maternity care). Four measures from the Consumer Assessment of Healthcare Providers and Systems were combined into a composite indicator of patient experience, reflecting the proportion of beneficiaries rating experiences as 8 or above on a 0-to-10–point scale. Outcome data were available for 248 plans (68% of plans operating prior to 2014, representing 78% of beneficiaries). Results Of the 366 comprehensive Medicaid managed care plans operating prior to 2014, 106 exited Medicaid. These exiting plans enrolled 4 848 310 Medicaid beneficiaries, with a mean of 606 039 beneficiaries affected by plan exits annually. Six states had a mean of greater than 10% of Medicaid managed care recipients enrolled in plans that exited, whereas 10 states experienced no plan exits. Plans that exited from a state’s Medicaid market performed significantly worse prior to exiting than those that remained in terms of preventive care (57.5% vs 60.4%; difference, 2.9% [95% CI, 0.3% to 5.5%]), maternity care (69.7% vs 73.6%; difference, 3.8% [95% CI, 1.7% to 6.0%]), and patient experience (73.5% vs 74.8%; difference, 1.3% [95% CI, 0.6% to 1.9%]). There was no significant difference between exiting and nonexiting plans for the quality of chronic disease care management (76.2% vs 77.1%; difference, 1.0% [95% CI, −2.1% to 4.0%]). There was also no significant change in overall market performance before and after the exit of a plan: 0.7–percentage point improvement in preventive care quality (95% CI, −4.9 to 6.3); 0.2–percentage point improvement in chronic disease care management quality (95% CI, −5.8 to 6.2); 0.7–percentage point decrease in maternity care quality (95% CI, −6.4 to 5.0]); and a 0.6–percentage point improvement in patient experience ratings (95% CI, −3.9 to 5.1). Medicaid beneficiaries enrolled in exiting plans had access to coverage for a higher-quality plan, with 78% of plans in the same county having higher quality for preventive care, 71.1% for chronic disease management, 65.5% for maternity care, and 80.8% for patient experience. Conclusions and Relevance Between 2006 and 2014, health plan exit from the US Medicaid program was frequent. Plans that exited generally had lower quality ratings than those that remained, and the exits were not associated with significant overall changes in quality or patient experience in the plans in the Medicaid market. PMID:28655014

  6. Association Between Health Plan Exit From Medicaid Managed Care and Quality of Care, 2006-2014.

    PubMed

    Ndumele, Chima D; Schpero, William L; Schlesinger, Mark J; Trivedi, Amal N

    2017-06-27

    State Medicaid programs have increasingly contracted with insurers to provide medical care services for enrollees (Medicaid managed care plans). Insurers that provide these plans can exit Medicaid programs each year, with unclear effects on quality of care and health care experiences. To determine the frequency and interstate variation of health plan exit from Medicaid managed care and evaluate the relationship between health plan exit and market-level quality. Retrospective cohort of all comprehensive Medicaid managed care plans (N = 390) during the interval 2006-2014. Plan exit, defined as the withdrawal of a managed care plan from a state's Medicaid program. Eight measures from the Healthcare Effectiveness Data and Information Set were used to construct 3 composite indicators of quality (preventive care, chronic disease care management, and maternity care). Four measures from the Consumer Assessment of Healthcare Providers and Systems were combined into a composite indicator of patient experience, reflecting the proportion of beneficiaries rating experiences as 8 or above on a 0-to-10-point scale. Outcome data were available for 248 plans (68% of plans operating prior to 2014, representing 78% of beneficiaries). Of the 366 comprehensive Medicaid managed care plans operating prior to 2014, 106 exited Medicaid. These exiting plans enrolled 4 848 310 Medicaid beneficiaries, with a mean of 606 039 beneficiaries affected by plan exits annually. Six states had a mean of greater than 10% of Medicaid managed care recipients enrolled in plans that exited, whereas 10 states experienced no plan exits. Plans that exited from a state's Medicaid market performed significantly worse prior to exiting than those that remained in terms of preventive care (57.5% vs 60.4%; difference, 2.9% [95% CI, 0.3% to 5.5%]), maternity care (69.7% vs 73.6%; difference, 3.8% [95% CI, 1.7% to 6.0%]), and patient experience (73.5% vs 74.8%; difference, 1.3% [95% CI, 0.6% to 1.9%]). There was no significant difference between exiting and nonexiting plans for the quality of chronic disease care management (76.2% vs 77.1%; difference, 1.0% [95% CI, -2.1% to 4.0%]). There was also no significant change in overall market performance before and after the exit of a plan: 0.7-percentage point improvement in preventive care quality (95% CI, -4.9 to 6.3); 0.2-percentage point improvement in chronic disease care management quality (95% CI, -5.8 to 6.2); 0.7-percentage point decrease in maternity care quality (95% CI, -6.4 to 5.0]); and a 0.6-percentage point improvement in patient experience ratings (95% CI, -3.9 to 5.1). Medicaid beneficiaries enrolled in exiting plans had access to coverage for a higher-quality plan, with 78% of plans in the same county having higher quality for preventive care, 71.1% for chronic disease management, 65.5% for maternity care, and 80.8% for patient experience. Between 2006 and 2014, health plan exit from the US Medicaid program was frequent. Plans that exited generally had lower quality ratings than those that remained, and the exits were not associated with significant overall changes in quality or patient experience in the plans in the Medicaid market.

  7. Viewing behaviour of spider phobics and non-phobics in the presence of threat and safety stimuli.

    PubMed

    Lange, W G T; Tierney, K J; Reinhardt-Rutland, A H; Vivekananda-Schmidt, P

    2004-09-01

    To determine whether spider phobics and spider non-phobics differ in attending to threat and safety stimuli in close proximity, or spatially separated. A sample group of 16 spider-phobic and 16 spider-non-phobic volunteers were drawn from a student population on the basis of their scores on Watts and Sharrock's Spider Phobia Questionnaire. Attention was assessed by way of participants' viewing behaviour using an ASL 501 head-mounted eye-tracking system. In a control condition, participants viewed a neutral stimulus (a TV video) in the absence of the threat stimulus. In two experimental conditions, the threat stimulus (a live Chilean rose tarantula) was introduced (a) immediately beside the safety stimulus (the only exit of the experimental room), or (b) away from the safety stimulus. In the experimental conditions, phobics reduced their viewing of the TV and increased their viewing of the tarantula and of the exit; the biggest changes occurred when tarantula and exit were together. Phobics also made more eye motions across the experimental room. Our results are consistent with previous research employing reaction time to a neutral stimulus as dependent measure. In addition, our results suggest that phobics scan the environment as part of safety behaviour. We suggest that exposure treatments to reduce spider phobia may be facilitated by encouraging patients to stop environmental scanning. Copyright 2004 The British Psychological Society

  8. 8- by 6-Foot Supersonic Wind Tunnel's Original Design

    NASA Image and Video Library

    1949-07-21

    Aerial view of the 8- by 6-Foot Supersonic Wind Tunnel in its original configuration at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. The 8- by 6 was the laboratory’s first large supersonic wind tunnel. It was also the NACA’s most powerful supersonic tunnel, and its first facility capable of running an engine at supersonic speeds. The 8- by 6-foot tunnel has been used to study inlets and exit nozzles, fuel injectors, flameholders, exit nozzles, and controls on ramjet and turbojet propulsion systems. The 8- by 6 was originally an open-throat and non-return tunnel. This meant that the supersonic air flow was blown through the test section and out the other end into the atmosphere. In this photograph, the three drive motors in the structure at the left supplied power to the seven-stage axial-flow compressor in the light-colored structure. The air flow passed through flexible walls which were bent to create the desired speed. The test article was located in the 8- by 6-foot stainless steel test section located inside the steel pressure chamber at the center of this photograph. The tunnel dimensions were then gradually increased to slow the air flow before it exited into the atmosphere. The large two-story building in front of the tunnel was used as office space for the researchers.

  9. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, Richard D. [Richland, WA; Udseth, Harold R. [Richland, WA; Olivares, Jose A. [Los Alamos, NM

    1994-10-18

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit.

  10. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, R.D.; Udseth, H.R.; Olivares, J.A.

    1994-10-18

    A system and method for analyzing molecular constituents of a composition sample include: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g.,{+-}2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit. 21 figs.

  11. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, R.P.; Udseth, H.R.; Olivares, J.A.

    1989-12-05

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., [+-]2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit. 21 figs.

  12. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, Richard P.; Udseth, Harold R.; Olivares, Jose A.

    1989-01-01

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit.

  13. Previous anxiety and depression as risk factors for early labour force exit.

    PubMed

    Rudolph, Kara E; Eaton, William W

    2016-04-01

    Individuals with a history of mental illness have lower earnings than individuals without. A possible reason is that those with prior anxiety or depression may be more likely to exit the labour force prior to retirement age, but evidence has been mixed and limited. Our objective was to compare risk of early labour force exit between employed adults with a history of depression or anxiety versus those without, separately for men and women. We used data from the Baltimore Epidemiological Catchment Area Follow-up Cohort, which collected baseline data in 1981 and follow-up data 1993-1996 and 2004-2005. Cox proportional hazards models estimated the relative risk of labour force exit comparing those with versus without prior history of anxiety or depressive disorders. Women with prior anxiety or depression are at 37% increased risk of dropping out of the labour force as compared to women without, controlling for age, socioeconomic status, race and marital status (HR: 1.37, 95% CI 1.04 to 1.79). Men with prior anxiety or depression are 18% more likely to subsequently drop out of the labour force as compared to men without, controlling for the above confounders as well as veteran status, but this association is not statistically significant (HR: 1.18, 95% CI 0.72 to 1.27). Prior anxiety or depression increases risk of early labour force exit for women. These findings may help explain previously reported lower earnings among female individuals with a history of mental illness and highlight the importance of considering anxiety and depressive disorders in policies supporting labour force participation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Attentional control of associative learning--a possible role of the central cholinergic system.

    PubMed

    Pauli, Wolfgang M; O'Reilly, Randall C

    2008-04-02

    How does attention interact with learning? Kruschke [Kruschke, J.K. (2001). Toward a unified Model of Attention in Associative Learning. J. Math. Psychol. 45, 812-863.] proposed a model (EXIT) that captures Mackintosh's [Mackintosh, N.J. (1975). A theory of attention: Variations in the associability of stimuli with reinforcement. Psychological Review, 82(4), 276-298.] framework for attentional modulation of associative learning. We developed a computational model that showed analogous interactions between selective attention and associative learning, but is significantly simplified and, in contrast to EXIT, is motivated by neurophysiological findings. Competition among input representations in the internal representation layer, which increases the contrast between stimuli, is critical for simulating these interactions in human behavior. Furthermore, this competition is modulated in a way that might be consistent with the phasic activation of the central cholinergic system, which modulates activity in sensory cortices. Specifically, phasic increases in acetylcholine can cause increased excitability of both pyramidal excitatory neurons in cortical layers II/III and cortical GABAergic inhibitory interneurons targeting the same pyramidal neurons. These effects result in increased attentional contrast in our model. This model thus represents an initial attempt to link human attentional learning data with underlying neural substrates.

  15. Attentional control of associative learning—A possible role of the central cholinergic system

    PubMed Central

    Pauli, Wolfgang M.; O'Reilly, Randall C.

    2010-01-01

    How does attention interact with learning? Kruschke [Kruschke, J.K. (2001). Toward a unified Model of Attention in Associative Learning. J. Math. Psychol. 45, 812–863.] proposed a model (EXIT) that captures Mackintosh's [Mackintosh, N.J. (1975). A theory of attention: Variations in the associability of stimuli with reinforcement. Psychological Review, 82(4), 276–298.] framework for attentional modulation of associative learning. We developed a computational model that showed analogous interactions between selective attention and associative learning, but is significantly simplified and, in contrast to EXIT, is motivated by neurophysiological findings. Competition among input representations in the internal representation layer, which increases the contrast between stimuli, is critical for simulating these interactions in human behavior. Furthermore, this competition is modulated in a way that might be consistent with the phasic activation of the central cholinergic system, which modulates activity in sensory cortices. Specifically, phasic increases in acetylcholine can cause increased excitability of both pyramidal excitatory neurons in cortical layers II/III and cortical GABAergic inhibitory interneurons targeting the same pyramidal neurons. These effects result in increased attentional contrast in our model. This model thus represents an initial attempt to link human attentional learning data with underlying neural substrates. PMID:17870060

  16. SU-F-T-258: Efficacy of Exit Fluence-Based Dose Calculation for Prostate Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siebers, J; Gardner, J; Neal, B

    Purpose: To investigate the efficacy of exit-fluence-based dose computation for prostate radiotherapy by determining if it estimates true dose more accurately than the original planning dose. Methods: Virtual exit-fluencebased dose computation was performed for 19 patients, each with 9–12 repeat CT images. For each patient, a 78 Gy treatment plan was created utilizing 5 mm CTV-to-PTV and OAR-to-PRV margins. A Monte Carlo framework was used to compute dose and exit-fluence images for the planning image and for each repeat CT image based on boney-anatomyaligned and prostate-centroid-aligned CTs. Identical source particles were used for the MC dose-computations on the planning andmore » repeat CTs to maximize correlation. The exit-fluence-based dose and image were computed by multiplying source particle weights by FC(x,y)=FP(x,y)/FT(x,y), where (x,y) are the source particle coordinates projected to the exit-fluence plane and we denote the dose/fluence from the plan by (DP,FP), from the repeat-CT as (DT,FT), and the exit-fluence computation by (DFC,FFC). DFC mimics exit-fluence backprojection through the planning image as FT=FFC. Dose estimates were intercompared to judge the efficacy of exit-fluence-based dose computation. Results: Boney- and prostate-centroid aligned results are combined as there is no statistical difference between them, yielding 420 dose comparisons per dose-volume metric. DFC is more accurate than DP for 46%, 33%, and 44% of cases in estimating CTV D98, D50, and D2 respectively. DFC improved rectum D50 and D2 estimates 54% and 49% respectively and bladder D50 and D2 47 and 49% respectively. While averaged over all patients and images DFC and DP were within 3.1% of DT, they differed from DT by as much as 22% for GTV D98, 71% for the Bladder D50, 17% for Bladder D2, 19% for Rectum D2. Conclusion: Exit-fluence based dose computations infrequently improve CTV or OAR dose estimates and should be used with caution. Research supported in part by Varian Medical Systems.« less

  17. 49. Environmental equipment room, cbr filter at left, ventilation control ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    49. Environmental equipment room, cbr filter at left, ventilation control panel in center, brine chiller controls at right, looking southeast - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  18. Lambert-St. Louis International Airport Data Package Number 5. Airport Improvement Task Force Delay Studies.

    DTIC Science & Technology

    1980-06-01

    conrol 25 34parrozre alrspacecosrit Is 06pazture queue 27 ? Amway cros sin; delay control d.* Aizcaraft Czeratioiaj (Mrter:stics 21 Exit taxiway %a±l... Amway identification 12, Departure runway aMnds 1 ittaxiway location 17General aLV4ation basinq areas C.A= procedurei Is Aircraft separations...Number of runwry. _____________________________ U3 Amway identification 1.2 Deparure runway end Linksj 13 Runay crassinq Links 14Exit taxiway

  19. Remote Sensing of In-Flight Icing Conditions: Operational, Meteorological, and Technological Considerations

    NASA Technical Reports Server (NTRS)

    Ryerson, Charles C.

    2000-01-01

    Remote-sensing systems that map aircraft icing conditions in the flight path from airports or aircraft would allow icing to be avoided and exited. Icing remote-sensing system development requires consideration of the operational environment, the meteorological environment, and the technology available. Operationally, pilots need unambiguous cockpit icing displays for risk management decision-making. Human factors, aircraft integration, integration of remotely sensed icing information into the weather system infrastructures, and avoid-and-exit issues need resolution. Cost, maintenance, power, weight, and space concern manufacturers, operators, and regulators. An icing remote-sensing system detects cloud and precipitation liquid water, drop size, and temperature. An algorithm is needed to convert these conditions into icing potential estimates for cockpit display. Specification development requires that magnitudes of cloud microphysical conditions and their spatial and temporal variability be understood at multiple scales. The core of an icing remote-sensing system is the technology that senses icing microphysical conditions. Radar and microwave radiometers penetrate clouds and can estimate liquid water and drop size. Retrieval development is needed; differential attenuation and neural network assessment of multiple-band radar returns are most promising to date. Airport-based radar or radiometers are the most viable near-term technologies. A radiometer that profiles cloud liquid water, and experimental techniques to use radiometers horizontally, are promising. The most critical operational research needs are to assess cockpit and aircraft system integration, develop avoid-and-exit protocols, assess human factors, and integrate remote-sensing information into weather and air traffic control infrastructures. Improved spatial characterization of cloud and precipitation liquid-water content, drop-size spectra, and temperature are needed, as well as an algorithm to convert sensed conditions into a measure of icing potential. Technology development also requires refinement of inversion techniques. These goals can be accomplished with collaboration among federal agencies including NASA, the FAA, the National Center for Atmospheric Research, NOAA, and the Department of Defense. This report reviews operational, meteorological, and technological considerations in developing the capability to remotely map in-flight icing conditions from the ground and from the air.

  20. Bed occupancy monitoring: data processing and clinician user interface design.

    PubMed

    Pouliot, Melanie; Joshi, Vilas; Goubran, Rafik; Knoefel, Frank

    2012-01-01

    Unobtrusive and continuous monitoring of patients, especially at their place of residence, is becoming a significant part of the healthcare model. A variety of sensors are being used to monitor different patient conditions. Bed occupancy monitoring provides clinicians a quantitative measure of bed entry/exit patterns and may provide information relating to sleep quality. This paper presents a bed occupancy monitoring system using a bed pressure mat sensor. A clinical trial was performed involving 8 patients to collect bed occupancy data. The trial period for each patient ranged from 5-10 weeks. This data was analyzed using a participatory design methodology incorporating clinician feedback to obtain bed occupancy parameters. The parameters extracted include the number of bed exits per night, the bed exit weekly average (including minimum and maximum), the time of day of a particular exit, and the amount of uninterrupted bed occupancy per night. The design of a clinical user interface plays a significant role in the acceptance of such patient monitoring systems by clinicians. The clinician user interface proposed in this paper was designed to be intuitive, easy to navigate and not cause information overload. An iterative design methodology was used for the interface design. The interface design is extendible to incorporate data from multiple sensors. This allows the interface to be part of a comprehensive remote patient monitoring system.

  1. System and method for making metallic iron with reduced CO.sub.2 emissions

    DOEpatents

    Kiesel, Richard F; Englund, David J; Schlichting, Mark; Meehan, John; Crouch, Jeremiah; Wilson, Logan

    2014-10-14

    A method and system for making metallic iron nodules with reduced CO.sub.2 emissions is disclosed. The method includes: assembling a linear hearth furnace having entry and exit portions, at least a conversion zone and a fusion zone, and a moving hearth adapted to move reducible iron bearing material through the furnace on contiguous hearth sections; assembling a shrouded return substantially free of air ingress extending adjacent at least the conversion and fusion zones of the furnace through which hearth sections can move from adjacent the exit portion to adjacent the entry portion of the furnace; transferring the hearth sections from the furnace to the shrouded return adjacent the exit portion; reducing reducible material in the linear hearth furnace to metallic iron nodules; and transporting gases from at least the fusion zone to the shrouded return to heat the hearth sections while in the shrouded return.

  2. Twin-belt continuous caster with containment and cooling of the exiting cast product for enabling high-speed casting of molten-center product

    DOEpatents

    Dykes, Charles D.; Daniel, Sabah S.; Wood, J. F. Barry

    1990-02-20

    In continuously casting molten metal into cast product by a twin-belt machine, it is desirable to achieve dramatic increases in speed (linear feet per minute) at which cast product exits the machine, particularly in installations where steel cast product is intended to feed a downstream regular rolling mill (as distinct from a planetary mill) operating in tandem with the twin-belt caster. Such high-speed casting produces product with a relatively thin shell and molten interior, and the shell tends to bulge outwardly due to metallostatic head pressure of the molten center. A number of cooperative features enable high-speed, twin-belt casting: (1) Each casting belt is slidably supported adjacent to the caster exit pulley for bulge control and enhanced cooling of cast product. (2) Lateral skew steering of each belt provides an effective increase in moving mold length plus a continuity of heat transfer not obtained with prior art belt steering apparatus. (3) The exiting slab is contained and supported downstream from the casting machine to prevent bulging of the shell of the cast product, and (4) spray cooling is incorporated in the exit containment apparatus for secondary cooling of cast product.

  3. Recent radial turbine research at the NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Rohlik, H. E.; Kofskey, M. G.

    1971-01-01

    The high efficiencies of small radial turbines led to their application in space power systems and numerous APU and shaft power engines. Experimental and analytical work associated with these systems included examination of blade-shroud clearance, blade loading, and exit diffuser design. Results indicate high efficiency over a wide range of specific speed and also insensitivity to clearance and blade loading in the radial part of the rotor. The exit diffuser investigation indicated that a conventional conical outer wall may not provide the velocity variation consistent with minimum overall diffuser loss.

  4. Design and Analyses of High Aspect Ratio Nozzles for Distributed Propulsion Acoustic Measurements

    NASA Technical Reports Server (NTRS)

    Dippold, Vance F., III

    2016-01-01

    A series of three convergent, round-to-rectangular high aspect ratio (HAR) nozzles were designed for acoustic testing at the NASA Glenn Research Center Nozzle Acoustic Test Rig (NATR). The HAR nozzles had exit area aspect ratios of 8:1, 12:1, and 16:1. The nozzles were designed to mimic a distributed propulsion system array with a slot nozzle. The nozzle designs were screened using Reynolds-Averaged Navier-Stokes (RANS) simulations. In addition to meeting the geometric constraints required for testing in the NATR, the HAR nozzles were designed to be free of flow features that would produce unwanted noise (e.g., flow separations) and to have uniform flow at the nozzle exit. Multiple methods were used to generate HAR nozzle designs. The final HAR nozzle designs were generated in segments using a computer code that parameterized each segment. RANS screening simulations showed that intermediate nozzle designs suffered flow separation, a normal shockwave at the nozzle exit (caused by an aerodynamic throat produced by boundary layer growth), and non-uniform flow at the nozzle exit. The RANS simulations showed that the final HAR nozzle designs were free of flow separations, but were not entirely successful at producing a fully uniform flow at the nozzle exit. The final designs suffered a pair of counter-rotating vortices along the outboard walls of the nozzle. The 16:1 aspect ratio HAR nozzle had the least uniform flow at the exit plane; the 8:1 aspect ratio HAR nozzles had a fairly uniform flow at the nozzle exit plane.

  5. Relevance of visual cues for orientation at familiar sites by homing pigeons: an experiment in a circular arena.

    PubMed Central

    Gagliardo, A.; Odetti, F.; Ioalè, P.

    2001-01-01

    Whether pigeons use visual landmarks for orientation from familiar locations has been a subject of debate. By recording the directional choices of both anosmic and control pigeons while exiting from a circular arena we were able to assess the relevance of olfactory and visual cues for orientation from familiar sites. When the birds could see the surroundings, both anosmic and control pigeons were homeward oriented. When the view of the landscape was prevented by screens that surrounded the arena, the control pigeons exited from the arena approximately in the home direction, while the anosmic pigeons' distribution was not different from random. Our data suggest that olfactory and visual cues play a critical, but interchangeable, role for orientation at familiar sites. PMID:11571054

  6. Performance of an asymmetric short annular diffuser with a nondiverging inner wall using suction. [control of radial profiles of diffuser exit velocity

    NASA Technical Reports Server (NTRS)

    Juhasz, A.

    1974-01-01

    The performance of a short highly asymmetric annular diffuser equipped with wall bleed (suction) capability was evaluated at nominal inlet Mach numbers of 0.188, 0.264, and 0.324 with the inlet pressure and temperature at near ambient values. The diffuser had an area ratio of 2.75 and a length- to inlet-height ratio of 1.6. Results show that the radial profiles of diffuser exit velocity could be controlled from a severely hub peaked to a slightly tip biased form by selective use of bleed. At the same time, other performance parameters were also improved. These results indicate the possible application of the diffuser bleed technique to control flow profiles to gas turbine combustors.

  7. Catching the Early Walker: An Examination of Potential Antecedents of Rapid Student Exit from Business-Related Undergraduate Degree Programmes in a Post-1992 University

    ERIC Educational Resources Information Center

    Bennett, Roger; Kottasz, Rita; Nocciolino, Julia

    2007-01-01

    Outputs from a computerised touch pad turnstile security system that recorded business students' entries into and exits from a university's buildings revealed that a significant number of the institution's first-year intake withdrew from their (business) degree programmes within a few weeks of enrolment. Accordingly, a sample of these "early…

  8. Exit-site infections by non-diphtheria corynebacteria in CAPD.

    PubMed

    Schiffl, Helmut; Mücke, Claudia; Lang, Susanne M

    2004-01-01

    Non-diphtheria corynebacteria species cause disease in risk populations such as immunocompromised patients and patients with indwelling medical devices. Despite reports of exit-site infection and peritonitis caused by non-diphtheria corynebacteria, these organisms are frequently dismissed as contaminants. During a 10-year observation period, we prospectively identified 8 cases of exit-site/tunnel infections caused by 2 different species of corynebacteria (Corynebacterium striatum in 5 and C. jeikeium in 3 cases). Four patients experienced a second episode of exit-site infection 3 months (2 cases), 25 months, and 40 months, respectively, after termination of an oral cephalosporin therapy of 4 to 6 weeks' duration. Non-diphtheria corynebacteria accounted for 9% of all exit-site infections during the study period. All catheter-related infections healed; no catheter had to be removed. The diagnosis of catheter-related non-diphtheria corynebacteria infection may be suspected when Gram stain shows gram-positive rods and with colony morphology and commercial biochemical identification systems. Susceptibility of non-diphtheria corynebacteria to antibiotics may vary, especially in C. jeikeium. Virtually all Corynebacterium species are sensitive to vancomycin. Empirical antibiotic therapy with vancomycin should be initiated while antibiotic susceptibility testing is being carried out. Oral cephalosporin may be an alternative treatment regimen for exit-site infections if sensitive. This study highlights the importance of non-diphtheria corynebacteria as emerging nosocomial pathogens in the population of end-stage renal disease patients on on continuous ambulatory peritoneal dialysis.

  9. Pressure variable orifice for hydraulic control valve

    NASA Technical Reports Server (NTRS)

    Ammerman, R. L.

    1968-01-01

    Hydraulic valve absorbs impact energy generated in docking or joining of two large bodies by controlling energy release to avoid jarring shock. The area of exit porting presented to the hydraulic control fluid is directly proportional to the pressure acting on the fluid.

  10. 71. View of launch control center towards the blast door ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    71. View of launch control center towards the blast door and west, deputy commander in B-52 seat - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  11. Simplified analysis and optimization of space base and space shuttle heat rejection systems

    NASA Technical Reports Server (NTRS)

    Wulff, W.

    1972-01-01

    A simplified radiator system analysis was performed to predict steady state radiator system performance. The system performance was found to be describable in terms of five non-dimensional system parameters. The governing differential equations are integrated numerically to yield the enthalpy rejection for the coolant fluid. The simplified analysis was extended to produce the derivatives of the coolant exit temperature with respect to the governing system parameters. A procedure was developed to find the optimum set of system parameters which yields the lowest possible coolant exit temperature for either a given projected area or a given total mass. The process can be inverted to yield either the minimum area or the minimum mass, together with the optimum geometry, for a specified heat rejection rate.

  12. Chaos as the hub of systems dynamics. The part I-The attitude control of spacecraft by involving in the heteroclinic chaos

    NASA Astrophysics Data System (ADS)

    Doroshin, Anton V.

    2018-06-01

    In this work the chaos in dynamical systems is considered as a positive aspect of dynamical behavior which can be applied to change systems dynamical parameters and, moreover, to change systems qualitative properties. From this point of view, the chaos can be characterized as a hub for the system dynamical regimes, because it allows to interconnect separated zones of the phase space of the system, and to fulfill the jump into the desirable phase space zone. The concretized aim of this part of the research is to focus on developing the attitude control method for magnetized gyrostat-satellites, which uses the passage through the intentionally generated heteroclinic chaos. The attitude dynamics of the satellite/spacecraft in this case represents the series of transitions from the initial dynamical regime into the chaotic heteroclinic regime with the subsequent exit to the final target dynamical regime with desirable parameters of the attitude dynamics.

  13. Toward Active Control of Noise from Hot Supersonic Jets

    DTIC Science & Technology

    2014-04-21

    regions of the jet. A retro -reflective shadowgraph setup was used to record the images. The near-nozzle region exhibits a large number of shock-like...jet exit plane; nearly identical observations have been made in the rocket noise community [15, 29| . The only discrepancies in figure 9b are with the...noise surveys of solid-fuel rocket engines for a range of nozzle exit pressures," NASA TN D-21, August, 1959. [16] Potter, R.C. and Jones, J.H., "An

  14. Control Optimization for a Dual-Mode Single-State Nuclear Shuttle,

    DTIC Science & Technology

    1980-01-01

    Variables at a •.2 as Functions of the Pump ! Power# ..... ............ ......... 36 ’’i I ’I [ I I OIAPTER I INTRODUCTION Since the end of the Apollo...If this is not the case, the assIumption is slightly optimistic. 4. The effective pump power and the reactor-exit stagnation tempar- ature are...independent of the reactor-exit stagnation pressure. I ("Effective puImp power" is the power required to pump the propellants, assumed to be incompressible

  15. Chromato-fluorographic drug detector. [device for detecting and recording fluorescent properties of materials

    NASA Technical Reports Server (NTRS)

    Parker, J. A.; Dimeff, J.; Heimbuch, A. H. (Inventor)

    1974-01-01

    A drug detecting apparatus which includes a chromatographic system for separating particular substances from a sample solution passed through it is described. A source of radiation causes the substance to emit fluorescent radiation as it moves through the chromatographic system. An optical system spectrally separates the fluorescent radiation according to wavelength and for focusing particular portions of the separated spectrum through an exit aperture. A photodetector which is responsive to the radiation passing through the exit aperture develops an electrical signal commensurate with the intensity of the radiation. The electrical signal is recorded to provide an indication of certain characteristics of the substance.

  16. Two blowing concepts for roll and lateral control of aircraft

    NASA Technical Reports Server (NTRS)

    Tavella, D. A.; Wood, N. J.; Lee, C. S.; Roberts, L.

    1986-01-01

    Two schemes to modulate aerodynamic forces for roll and lateral control of aircraft have been investigated. The first scheme, called the lateral blowing concept, consists of thin jets of air exiting spanwise, or at small angle with the spanwise direction, from slots at the tips of straight wings. For this scheme, in addition to experimental measurements, a theory was developed showing the analytical relationship between aerodynamic forces and jet and wing parameters. Experimental results confirmed the theoretically derived scaling laws. The second scheme, which was studied experimentally, is called the jet spoiler concept and consists of thin jets exiting normally to the wing surface from slots aligned with the spanwise direction.

  17. T cell exit from quiescence and differentiation into Th2 cells depend on Raptor-mTORC1-mediated metabolic programming

    PubMed Central

    Yang, Kai; Shrestha, Sharad; Zeng, Hu; Karmaus, Peer W.F.; Neale, Geoffrey; Vogel, Peter; Guertin, David A.; Lamb, Richard F.; Chi, Hongbo

    2014-01-01

    SUMMARY Naïve T cells respond to antigen stimulation by exiting from quiescence and initiating clonal expansion and functional differentiation, but the control mechanism is elusive. Here we describe that Raptor-mTORC1-dependent metabolic programming is a central determinant of this transitional process. Loss of Raptor abrogated T cell priming and Th2 cell differentiation, although Raptor function is less important for continuous proliferation of actively cycling cells. mTORC1 coordinated multiple metabolic programs in T cells including glycolysis, lipid synthesis and oxidative phosphorylation to mediate antigen-triggered exit from quiescence. mTORC1 further linked glucose metabolism to the initiation of Th2 cell differentiation by orchestrating cytokine receptor expression and cytokine responsiveness. Activation of Raptor-mTORC1 integrated T cell receptor and CD28 co-stimulatory signals in antigen-stimulated T cells. Our studies identify a Raptor-mTORC1-dependent pathway linking signal-dependent metabolic reprogramming to quiescence exit, and this in turn coordinates lymphocyte activation and fate decisions in adaptive immunity. PMID:24315998

  18. Serial Escape System For Aircraft Crews

    NASA Technical Reports Server (NTRS)

    Wood, Kenneth E.

    1990-01-01

    Emergency escape system for aircraft and aerospace vehicles ejects up to seven crewmembers, one by one, within 120 s. Intended for emergencies in which disabled craft still in stable flight at no more than 220 kn (113 m/s) equivalent airspeed and sinking no faster than 110 ft/s (33.5 m/s) at altitudes up to 50,000 ft (15.2 km). Ejection rockets load themselves from magazine after each crewmember ejected. Jumpmaster queues other crewmembers and helps them position themselves on egress ramp. Rockets pull crewmembers clear of aircraft structure. Provides orderly, controlled exit and avoids ditching at sea or landing in rough terrain.

  19. Improved chain control operations.

    DOT National Transportation Integrated Search

    2010-01-01

    In California, field maintenance personnel use turntable signs to advise motorists of chain control conditions on rural : highways and freeways. To do this an operator has to park, exit the vehicle, turn the sign on the shoulder and then : walk acros...

  20. Quality of life and functioning of Hispanic patients with Major Depressive Disorder before and after treatment.

    PubMed

    López, Enrique; Steiner, Alexander J; Manier, Karra; Shapiro, Bryan B; Vanle, Brigitte; Parisi, Thomas; Dang, Jonathan; Chang, Tiffany; Ganjian, Shaina; Mirocha, James; Danovitch, Itai; IsHak, Waguih William

    2018-01-01

    Similar rates of remission from Major Depressive Disorder (MDD) have been documented between ethnic groups in response to antidepressant treatment. However, ethnic differences in functional outcomes, including patient-reported quality of life (QOL) and functioning, have not been well-characterized. We compared symptomatic and functional outcomes of antidepressant treatment in Hispanic and non-Hispanic patients with MDD. We analyzed 2280 nonpsychotic treatment-seeking adults with MDD who received citalopram monotherapy in Level 1 of the Sequenced Treatment Alternatives to Relieve Depression study. All subjects (239 Hispanic, 2041 non-Hispanic) completed QOL, functioning, and depressive symptom severity measures at entry and exit. Hispanic participants had significantly worse QOL scores at entry and exit (p < 0.01). However, after controlling for baseline QOL, there was no difference between Hispanic and non-Hispanic patients' QOL at exit (p = 0.21). There were no significant between-group differences at entry or at exit for depressive symptom severity or functioning. Both groups had significant improvements in depressive symptom severity, QOL, and functioning from entry to exit (all p values < 0.01). Patients with private insurance had lower depressive symptom severity, greater QOL, and better functioning at exit compared to patients without private insurance. This study was a retrospective data analysis, and the Hispanic group was relatively small compared to the non-Hispanic group. Hispanic and non-Hispanic participants with MDD had similar responses to antidepressant treatment as measured by depressive symptom severity scores, quality of life, and functioning. Nevertheless, Hispanic patients reported significantly worse quality of life at entry. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The relationship between substance use and exit security on psychiatric wards.

    PubMed

    Simpson, Alan; Bowers, Len; Haglund, Kristina; Muir-Cochrane, Eimear; Nijman, Henk; Van der Merwe, Marie

    2011-03-01

    In this paper we report on the rates of drug/alcohol use on acute psychiatric wards in relation to levels and intensity of exit security measures. Many inpatient wards have become permanently locked, with staff concerned about the risk of patients leaving the ward and harming themselves or others, and of people bringing illicit substances into the therapeutic environment. In 2004/2005, a cross sectional survey on 136 acute psychiatric wards across three areas of England was undertaken. A comprehensive range of data including door locking and drug/alcohol use were collected over 6 months on each ward. In 2006, supplementary data on door locking and exit security were collected. Door locking, additional exit security measures and substance misuse rates of the 136 wards were analysed and the associations between these were investigated. No consistent relationships were found with exit security features, intensity of drug/alcohol monitoring procedures, or the locking of the ward door. There were indications that use of breath testing for alcohol might reduce usage and that the use of 'sniffer' dogs was associated with greater alcohol use. Greater exit security or locking of the ward door had no influence on rates of use of alcohol or illicit drugs by inpatients and thus cannot form part of any strategy to control substance use by inpatients. There are some grounds to believe that a greater use of screening might help reduce the frequency of alcohol/substance use on wards and may lead to a reduction in verbal abuse. © 2010 The Authors. Journal of Advanced Nursing © 2010 Blackwell Publishing Ltd.

  2. An item response theory analysis of the Executive Interview and development of the EXIT8: A Project FRONTIER Study.

    PubMed

    Jahn, Danielle R; Dressel, Jeffrey A; Gavett, Brandon E; O'Bryant, Sid E

    2015-01-01

    The Executive Interview (EXIT25) is an effective measure of executive dysfunction, but may be inefficient due to the time it takes to complete 25 interview-based items. The current study aimed to examine psychometric properties of the EXIT25, with a specific focus on determining whether a briefer version of the measure could comprehensively assess executive dysfunction. The current study applied a graded response model (a type of item response theory model for polytomous categorical data) to identify items that were most closely related to the underlying construct of executive functioning and best discriminated between varying levels of executive functioning. Participants were 660 adults ages 40 to 96 years living in West Texas, who were recruited through an ongoing epidemiological study of rural health and aging, called Project FRONTIER. The EXIT25 was the primary measure examined. Participants also completed the Trail Making Test and Controlled Oral Word Association Test, among other measures, to examine the convergent validity of a brief form of the EXIT25. Eight items were identified that provided the majority of the information about the underlying construct of executive functioning; total scores on these items were associated with total scores on other measures of executive functioning and were able to differentiate between cognitively healthy, mildly cognitively impaired, and demented participants. In addition, cutoff scores were recommended based on sensitivity and specificity of scores. A brief, eight-item version of the EXIT25 may be an effective and efficient screening for executive dysfunction among older adults.

  3. Long-term effects of psychosocial work stress in midlife on health functioning after labor market exit--results from the GAZEL study.

    PubMed

    Wahrendorf, Morten; Sembajwe, Grace; Zins, Marie; Berkman, Lisa; Goldberg, Marcel; Siegrist, Johannes

    2012-07-01

    To study long-term effects of psychosocial work stress in mid-life on health functioning after labor market exit using two established work stress models. In the frame of the prospective French Gazel cohort study, data on psychosocial work stress were assessed using the full questionnaires measuring the demand-control-support model (in 1997 and 1999) and the effort-reward imbalance model (in 1998). In 2007, health functioning was assessed, using the Short Form 36 mental and physical component scores. Multivariate regressions were calculated to predict health functioning in 2007, controlling for age, gender, social position, and baseline self-perceived health. Consistent effects of both work stress models and their single components on mental and physical health functioning during retirement were observed. Effects remained significant after adjustment including baseline self-perceived health. Whereas the predictive power of both work stress models was similar in the case of the physical composite score, in the case of the mental health score, values of model fit were slightly higher for the effort-reward imbalance model (R(2): 0.13) compared with the demand-control model (R²: 0.11). Findings underline the importance of working conditions in midlife not only for health in midlife but also for health functioning after labor market exit.

  4. A beam splitter of natural light guiding system based on dichroic prism for ecological illumination

    NASA Astrophysics Data System (ADS)

    Li, Yu-Chi; Chen, Yi-Yung; Whang, Allen Jong-Woei

    2009-08-01

    In thremmatology, many researches focus on ecological illumination for improving the growing speed of animal or plant. According to the Trichromatic theory, any specific color can be made up of red, green, and blue light. Sunlight has full spectrum so it is the most applicable source. A Natural Light Guiding System includes collecting, transmitting, and lighting parts. In our research, we would like to design a beam splitter in the transmitting part to separate the sunlight into red, green, and blue light for ecological illumination. We use high pass and low pass dichroic coatings in a prism, called dichroic prism, to be the beam splitter to separate the wavelength. For measuring the spectra of the exit beams, we build a space with the Natural Light Guiding System. In the space, the spectra of sunlight outside and inside the space and the exit beams of the beam splitter are measured. Finally, we use prismatic structure to design the beam splitter, and optimize the surface of the element with aspheric surface and Fresnel surface to reduce the beam angle of exit light.

  5. The Correlates and Consequences of Welfare Exit and Entry: Evidence from the Three-City Study. Working Paper.

    ERIC Educational Resources Information Center

    Moffitt, Robert; Winder, Katie

    The dramatic decline in Temporary Assistance for Needy Families (TANF) caseloads in the 1990s has focused attention on the process of exit from, and, to a lesser extent, entry into, the welfare system. This paper charts the process of turnover in the TANF program in three major U.S. cities over an 18-month, post-PWORA period and documents its…

  6. Technology Evaluation and Integration for Heavy Tactical Vehicles

    DTIC Science & Technology

    2010-08-17

    for Movie - May have to Exit slide show mode UNCLASSIFIED Key Findings- Modular Hydraulic Powered Generator • Hydraulic powered alternator proved...for Movie - May have to Exit slide show mode UNCLASSIFIED PPMS Key Findings Findings: • Hybrid starting system proved functional • Works with wide...to compute inter- vehicle closing distance & stopping time. • Provide audible/visual alert to driver inside their reaction time window. • Use COTS

  7. Drivers’ Visual Characteristics when Merging onto or Exiting an Urban Expressway

    PubMed Central

    Cheng, Ying; Gao, Li; Zhao, Yanan; Du, Feng

    2016-01-01

    The aim of this study is to examine drivers’ visual and driving behavior while merging onto or exiting an urban expressway with low and high traffic densities. The analysis was conducted according to three periods (approaching, merging or exiting, and accelerating or decelerating). A total of 10 subjects (8 males and 2 females) with ages ranging from 25 to 52 years old (M = 30.0 years old) participated in the study. The research was conducted in a natural driving situation, and the drivers’ eye movements were monitored and recorded using an eye tracking system. The results show that the influence of traffic density on the glance duration and scan duration is more significant when merging than when exiting. The results also demonstrate that the number of glances and the mean glance duration are mainly related to the driving task (e.g., the merging period). Therefore, drivers’ visual search strategies mainly depend on the current driving task. With regard to driving behavior, the variation tendencies of the duration and the velocity of each period are similar. These results support building an automated driving assistant system that can automatically identify gaps and accelerate or decelerate the car accordingly or provide suggestions to the driver to do so. PMID:27657888

  8. Supersonic Injection of Aerated Liquid Jet

    NASA Astrophysics Data System (ADS)

    Choudhari, Abhijit; Sallam, Khaled

    2016-11-01

    A computational study of the exit flow of an aerated two-dimensional jet from an under-expanded supersonic nozzle is presented. The liquid sheet is operating within the annular flow regime and the study is motivated by the application of supersonic nozzles in air-breathing propulsion systems, e.g. scramjet engines, ramjet engines and afterburners. The simulation was conducted using VOF model and SST k- ω turbulence model. The test conditions included: jet exit of 1 mm and mass flow rate of 1.8 kg/s. The results show that air reaches transonic condition at the injector exit due to the Fanno flow effects in the injector passage. The aerated liquid jet is alternately expanded by Prandtl-Meyer expansion fan and compressed by oblique shock waves due to the difference between the back (chamber) pressure and the flow pressure. The process then repeats itself and shock (Mach) diamonds are formed at downstream of injector exit similar to those typical of exhaust plumes of propulsion system. The present results, however, indicate that the flow field of supersonic aerated liquid jet is different from supersonic gas jets due to the effects of water evaporation from the liquid sheet. The contours of the Mach number, static pressure of both cases are compared to the theory of gas dynamics.

  9. Nitrate, Nitrite, and Ammonium Variability in Drinking Water Distribution Systems.

    PubMed

    Schullehner, Jörg; Stayner, Leslie; Hansen, Birgitte

    2017-03-09

    Accurate assessments of exposure to nitrate in drinking water is a crucial part of epidemiological studies investigating long-term adverse human health effects. However, since drinking water nitrate measurements are usually collected for regulatory purposes, assumptions on (1) the intra-distribution system variability and (2) short-term (seasonal) concentration variability have to be made. We assess concentration variability in the distribution system of nitrate, nitrite, and ammonium, and seasonal variability in all Danish public waterworks from 2007 to 2016. Nitrate concentrations at the exit of the waterworks are highly correlated with nitrate concentrations within the distribution net or at the consumers' taps, while nitrite and ammonium concentrations are generally lower within the net compared with the exit of the waterworks due to nitrification. However, nitrification of nitrite and ammonium in the distribution systems only results in a relatively small increase in nitrate concentrations. No seasonal variation for nitrate, nitrite, or ammonium was observed. We conclude that nitrate measurements taken at the exit of the waterworks are suitable to calculate exposures for all consumers connected to that waterworks and that sampling frequencies in the national monitoring programme are sufficient to describe temporal variations in longitudinal studies.

  10. Nitrate, Nitrite, and Ammonium Variability in Drinking Water Distribution Systems

    PubMed Central

    Schullehner, Jörg; Stayner, Leslie; Hansen, Birgitte

    2017-01-01

    Accurate assessments of exposure to nitrate in drinking water is a crucial part of epidemiological studies investigating long-term adverse human health effects. However, since drinking water nitrate measurements are usually collected for regulatory purposes, assumptions on (1) the intra-distribution system variability and (2) short-term (seasonal) concentration variability have to be made. We assess concentration variability in the distribution system of nitrate, nitrite, and ammonium, and seasonal variability in all Danish public waterworks from 2007 to 2016. Nitrate concentrations at the exit of the waterworks are highly correlated with nitrate concentrations within the distribution net or at the consumers’ taps, while nitrite and ammonium concentrations are generally lower within the net compared with the exit of the waterworks due to nitrification. However, nitrification of nitrite and ammonium in the distribution systems only results in a relatively small increase in nitrate concentrations. No seasonal variation for nitrate, nitrite, or ammonium was observed. We conclude that nitrate measurements taken at the exit of the waterworks are suitable to calculate exposures for all consumers connected to that waterworks and that sampling frequencies in the national monitoring programme are sufficient to describe temporal variations in longitudinal studies. PMID:28282914

  11. Control methods and systems for indirect evaporative coolers

    DOEpatents

    Woods, Jason; Kozubal, Erik

    2015-09-22

    A control method for operating an indirect evaporative cooler to control temperature and humidity. The method includes operating an airflow control device to provide supply air at a flow rate to a liquid desiccant dehumidifier. The supply air flows through the dehumidifier and an indirect evaporative cooler prior to exiting an outlet into a space. The method includes operating a pump to provide liquid desiccant to the liquid desiccant dehumidifier and sensing a temperature of an airstream at the outlet of the indirect evaporative cooler. The method includes comparing the temperature of the airstream at the outlet to a setpoint temperature at the outlet and controlling the pump to set the flow rate of the liquid desiccant. The method includes sensing space temperature, comparing the space temperature with a setpoint temperature, and controlling the airflow control device to set the flow rate of the supply air based on the comparison.

  12. Evaluation of six TPS algorithms in computing entrance and exit doses

    PubMed Central

    Metwaly, Mohamed; Glegg, Martin; Baggarley, Shaun P.; Elliott, Alex

    2014-01-01

    Entrance and exit doses are commonly measured in in vivo dosimetry for comparison with expected values, usually generated by the treatment planning system (TPS), to verify accuracy of treatment delivery. This report aims to evaluate the accuracy of six TPS algorithms in computing entrance and exit doses for a 6 MV beam. The algorithms tested were: pencil beam convolution (Eclipse PBC), analytical anisotropic algorithm (Eclipse AAA), AcurosXB (Eclipse AXB), FFT convolution (XiO Convolution), multigrid superposition (XiO Superposition), and Monte Carlo photon (Monaco MC). Measurements with ionization chamber (IC) and diode detector in water phantoms were used as a reference. Comparisons were done in terms of central axis point dose, 1D relative profiles, and 2D absolute gamma analysis. Entrance doses computed by all TPS algorithms agreed to within 2% of the measured values. Exit doses computed by XiO Convolution, XiO Superposition, Eclipse AXB, and Monaco MC agreed with the IC measured doses to within 2%‐3%. Meanwhile, Eclipse PBC and Eclipse AAA computed exit doses were higher than the IC measured doses by up to 5.3% and 4.8%, respectively. Both algorithms assume that full backscatter exists even at the exit level, leading to an overestimation of exit doses. Despite good agreements at the central axis for Eclipse AXB and Monaco MC, 1D relative comparisons showed profiles mismatched at depths beyond 11.5 cm. Overall, the 2D absolute gamma (3%/3 mm) pass rates were better for Monaco MC, while Eclipse AXB failed mostly at the outer 20% of the field area. The findings of this study serve as a useful baseline for the implementation of entrance and exit in vivo dosimetry in clinical departments utilizing any of these six common TPS algorithms for reference comparison. PACS numbers: 87.55.‐x, 87.55.D‐, 87.55.N‐, 87.53.Bn PMID:24892349

  13. Particle injector for fluid systems

    DOEpatents

    Ruch, Jeffrey F.

    1997-01-01

    A particle injector device provides injection of particles into a liquid eam. The device includes a funnel portion comprising a conical member having side walls tapering from a top opening (which receives the particles) down to a relatively smaller exit opening. A funnel inlet receives a portion of the liquid stream and the latter is directed onto the side walls of the conical member so as to create a cushion of liquid against which the particles impact. A main section of the device includes an inlet port in communication with the exit opening of the funnel portion. A main liquid inlet receives the main portion of the liquid stream at high pressure and low velocity and a throat region located downstream of the main liquid inlet accelerates liquid received by this inlet from the low velocity to a higher velocity so as to create a low pressure area at the exit opening of the funnel portion. An outlet opening of the main section enables the particles and liquid stream to exit from the injector device.

  14. Real jet effects on dual jets in a crossflow

    NASA Technical Reports Server (NTRS)

    Schetz, J. A.

    1984-01-01

    A 6-ft by 6-ft wind tunnel section was modification to accommodate the 7-ft wide NASA dual-jet flate model in an effort to determine the effects of nonuniform and/or noncircular jet exhaust profiles on the pressure field induced on a nearby surface. Tests completed yield surface pressure measurements for a 90 deg circular injector producing exit profiles representative of turbofan nozzles (such as the TF-34 nozzle). The measurements were obtained for both tandem and side-by-side jet configurations, jet spacing of S/D =2, and velocity ratios of R=2.2 and 4.0. Control tests at the same mass flow rate but with uniform exit velocity profiles were also conducted, for comparison purposes. Plots for 90 deg injection and R=2.2 show that the effects of exit velocity profile nonuniformity are quite significant.

  15. Effect of Injector Geometry on Atomization of a Liquid-Liquid Double Swirl Coaxial Injector Using Non-invasive Laser, Optical and X-ray Techniques

    NASA Technical Reports Server (NTRS)

    Radke, C. R.; Meyer, T. R.

    2014-01-01

    The spray characteristics of a liquid-liquid double swirl coaxial injector were studied using non-invasive optical, laser, and X-ray diagnostics. A parametric study of injector exit geometry demonstrated that spray breakup time, breakup type and sheet stability could be controlled with exit geometry. Phase Doppler interferometry was used to characterize droplet statistics and non-dimensional droplet parameters over a range of inlet conditions and for various fluids allowing for a study on the role of specific fluid properties in atomization. Further, X-ray radiography allowed for investigation of sheet thickness and breakup length to be quantified for different recess exit diameters and inlet pressures. Finally, computed tomography scans revealed that the spray cone was distinctively non-uniform and comprised of several pockets of increased mass flux.

  16. Effect of Injector Geometry on Atomization of a Liquid-Liquid Double Swirl Coaxial Injector using Non-Invasive Laser, Optical and X-ray Techniques

    NASA Technical Reports Server (NTRS)

    Radke, C. R.; Meyer, T. R.

    2014-01-01

    The spray characteristics of a Liquid-Liquid Double Swirl Coaxial Injector were studied using noninvasive Optical, Laser, and X-ray diagnostics. A parametric study of injector exit geometry demonstrated that spray breakup time, breakup type and sheet stability could be controlled with exit geometry. Phase Doppler Particle Analysis characterized droplet statistics and non-dimensional droplet parameters over a range of inlet conditions and for various fluids allowing for a study on the role of specific fluid properties in atomization. Further, x-ray radiographs allowed for investigations of sheet thickness and breakup length to be quantified for different recess exits and inlet pressures. Finally Computed Tomography scans revealed that the spray cone was distinctively non-uniform and comprised of several pockets of increased mass flux.

  17. 73. View of launch control center towards the blast door ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    73. View of launch control center towards the blast door and west, deputy commander standing in front of modular bed storage unit - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  18. 60. Shock isolator at center, pneumatic control group panel at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. Shock isolator at center, pneumatic control group panel at left, power distribution box at right, all at right of entrance to lcc. - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  19. 15. Interior view of unoccupied controlled computer room looking at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Interior view of unoccupied controlled computer room looking at exit door and office; northwest corner of unoccupied portion; view to south. - Ellsworth Air Force Base, Mess & Administration Building, 2279 Risner Drive, Blackhawk, Meade County, SD

  20. Leveraging Competence in the Use of Leveraging Collaborative Tools Competence: facilitating an Open Architecture Approach to Acquiring Integrated Warfare Systems

    DTIC Science & Technology

    2006-12-30

    Nonresponse Bias in Mail Surveys,” Journal of Marketing Research , 19, (1976), pp. 396-402. Bandura, A., Self-efficacy: The exercise of control, New York: W.H...Journal of Marketing Research , 16, 1, (1979), pp. 64-73. Communication News, “Web Meetings Benefit Bottom Line,” Communication News, 40, 6, (2003...Structural Equation Models: LISREL and PLS Applied to Consumer Exit-Voice Theory," Journal of Marketing Research , 19, (1982), 440-452. Grantham, C.E. and L

  1. Educational Inequalities in Exit from Paid Employment among Dutch Workers: The Influence of Health, Lifestyle and Work.

    PubMed

    Robroek, Suzan J W; Rongen, Anne; Arts, Coos H; Otten, Ferdy W H; Burdorf, Alex; Schuring, Merel

    2015-01-01

    Individuals with lower socioeconomic status are at increased risk of involuntary exit from paid employment. To give sound advice for primary prevention in the workforce, insight is needed into the role of mediating factors between socioeconomic status and labour force participation. Therefore, it is aimed to investigate the influence of health status, lifestyle-related factors and work characteristics on educational differences in exit from paid employment. 14,708 Dutch employees participated in a ten-year follow-up study during 1999-2008. At baseline, education, self-perceived health, lifestyle (smoking, alcohol, sports, BMI) and psychosocial (demands, control, rewards) and physical work characteristics were measured by questionnaire. Employment status was ascertained monthly based on tax records. The relation between education, health, lifestyle, work-characteristics and exit from paid employment through disability benefits, unemployment, early retirement and economic inactivity was investigated by competing risks regression analyses. The mediating effects of these factors on educational differences in exit from paid employment were tested using a stepwise approach. Lower educated workers were more likely to exit paid employment through disability benefits (SHR:1.84), unemployment (SHR:1.74), and economic inactivity (SHR:1.53) but not due to early retirement (SHR:0.92). Poor or moderate health, an unhealthy lifestyle, and unfavourable work characteristics were associated with disability benefits and unemployment, and an unhealthy lifestyle with economic inactivity. Educational differences in disability benefits were explained for 40% by health, 31% by lifestyle, and 12% by work characteristics. For economic inactivity and unemployment, up to 14% and 21% of the educational differences could be explained, particularly by lifestyle-related factors. There are educational differences in exit from paid employment, which are partly mediated by health, lifestyle and work characteristics, particularly for disability benefits. Health promotion and improving working conditions seem important measures to maintain a productive workforce, particularly among workers with a low education.

  2. 3% Amuchina is as effective as the 50% concentration in the prevention of exit-site infection in children on chronic peritoneal dialysis.

    PubMed

    Grosman, Mònica D; Mosquera, Vanesa M; Hernandez, Maria G; Agostini, Silvana; Adragna, Marta; Sojo, Ernesto T

    2005-01-01

    In a previous communication, we demonstrated that, in the prevention of exit-site infection (ESI) in children, the cleansing agent 50% Amuchina (electrolytic chloroxidizer. Amuchina SpA, Genoa, Italy) is more effective than 10% povidone iodine and as effective as 4% chlorhexidine, but with fewer adverse secondary effects. In the present study, we assessed, in an Argentine pediatric population, whether Amuchina 3% is as effective as Amuchina 50% in preventing ESI in children on chronic peritoneal dialysis. In an open-label, single-center prospective study, 27 children (mean age: 7.2 years; range: 1.7-17 years) used 3% Amuchina as a cleansing agent for the daily care of a healthy exit site. Of the 27 children, 14 were switched from 50% Amuchina to 3% Amuchina, and 13 were using the 3% Amuchina for the first time. The control group consisted of 18 patients who had previously used 50% Amuchina as a cleansing agent. We followed the recommendations of the International Society for Peritoneal Dialysis with regard to exit-site care, which include keeping the cleansing agent out of the sinus and rinsing the exit site with sterile water. Amuchina was used from the first post-implantation care of the exit site. No adverse secondary effects were seen with the use of Amuchina at either concentration. Patients using 3% Amuchina presented an ESI rate similar to that of patients using Amuchina 50%. The cost of 3% Amuchina was significantly lower than that of the 50% concentration, and it was even lower than the cost for 10% povidone iodine or 4% chlorhexidine. Although more research trials are needed to assess the efficacy of 3% Amuchina, we conclude that 3% Amuchina is the best and most cost-effective cleansing agent for the daily care of a healthy exit site in children on chronic peritoneal dialysis.

  3. Educational Inequalities in Exit from Paid Employment among Dutch Workers: The Influence of Health, Lifestyle and Work

    PubMed Central

    Robroek, Suzan J. W.; Rongen, Anne; Arts, Coos H.; Otten, Ferdy W. H.; Burdorf, Alex; Schuring, Merel

    2015-01-01

    Background Individuals with lower socioeconomic status are at increased risk of involuntary exit from paid employment. To give sound advice for primary prevention in the workforce, insight is needed into the role of mediating factors between socioeconomic status and labour force participation. Therefore, it is aimed to investigate the influence of health status, lifestyle-related factors and work characteristics on educational differences in exit from paid employment. Methods 14,708 Dutch employees participated in a ten-year follow-up study during 1999–2008. At baseline, education, self-perceived health, lifestyle (smoking, alcohol, sports, BMI) and psychosocial (demands, control, rewards) and physical work characteristics were measured by questionnaire. Employment status was ascertained monthly based on tax records. The relation between education, health, lifestyle, work-characteristics and exit from paid employment through disability benefits, unemployment, early retirement and economic inactivity was investigated by competing risks regression analyses. The mediating effects of these factors on educational differences in exit from paid employment were tested using a stepwise approach. Results Lower educated workers were more likely to exit paid employment through disability benefits (SHR:1.84), unemployment (SHR:1.74), and economic inactivity (SHR:1.53) but not due to early retirement (SHR:0.92). Poor or moderate health, an unhealthy lifestyle, and unfavourable work characteristics were associated with disability benefits and unemployment, and an unhealthy lifestyle with economic inactivity. Educational differences in disability benefits were explained for 40% by health, 31% by lifestyle, and 12% by work characteristics. For economic inactivity and unemployment, up to 14% and 21% of the educational differences could be explained, particularly by lifestyle-related factors. Conclusions There are educational differences in exit from paid employment, which are partly mediated by health, lifestyle and work characteristics, particularly for disability benefits. Health promotion and improving working conditions seem important measures to maintain a productive workforce, particularly among workers with a low education. PMID:26252013

  4. Flume experimentation and simulation of bedrock channel processes

    NASA Astrophysics Data System (ADS)

    Thompson, Douglas; Wohl, Ellen

    Flume experiments can provide cost effective, physically manageable miniature representations of complex bedrock channels. The inherent change in scale in such experiments requires a corresponding change in the scale of the forces represented in the flume system. Three modeling approaches have been developed that either ignore the scaling effects, utilize the change in scaled forces, or assume similarity of process between scales. An understanding of the nonlinear influence of a change in scale on all the forces involved is important to correctly analyze model results. Similarly, proper design and operation of flume experiments requires knowledge of the fundamental components of flume systems. Entrance and exit regions of the flume are used to provide good experimental conditions in the measurement region of the flume where data are collected. To insure reproducibility, large-scale turbulence must be removed in the head of the flume and velocity profiles must become fully developed in the entrance region. Water-surface slope and flow acceleration effects from downstream water-depth control must also be isolated in the exit region. Statistical design and development of representative channel substrate also influence model results in these systems. With proper experimental design, flumes may be used to investigate bedrock channel hydraulics, sediment-transport relations, and morphologic evolution. In particular, researchers have successfully used flume experiments to demonstrate the importance of turbulence and substrate characteristics in bedrock channel evolution. Turbulence often operates in a self perpetuating fashion, can erode bedrock walls with clear water and increase the mobility of sediment particles. Bedrock substrate influences channel evolution by offering varying resistance to erosion, controlling the location or type of incision and modifying the local influence of turbulence. An increased usage of scaled flume models may help to clarify the remaining uncertainties involving turbulence, channel substrate and bedrock channel evolution.

  5. KSC-00pp1601

    NASA Image and Video Library

    2000-10-23

    In the Space Station Processing Facility, a worker is surprised by the camera as she exits the U.S. Lab, Destiny. Inside the lab is the STS-98 crew, which is taking part in Crew Equipment Interface Test activities, becoming familiar with equipment it will be handling during the mission. The crew comprises Commander Ken Cockrell, Pilot Mark Polansky and Mission Specialists Robert Curbeam, Thomas Jones and Marsha Ivins. The mission will be transporting the Lab to the International Space Station with five system racks already installed inside of the module. With delivery of electronics in the lab, electrically powered attitude control for Control Moment Gyroscopes will be activated. The STS-98 launch is scheduled for Jan. 18, 2001

  6. STS-98 crew members take part in CEIT

    NASA Technical Reports Server (NTRS)

    2000-01-01

    In the Space Station Processing Facility, a worker is surprised by the camera as she exits the U.S. Lab, Destiny. Inside the lab is the STS-98 crew, which is taking part in Crew Equipment Interface Test activities, becoming familiar with equipment it will be handling during the mission. The crew comprises Commander Ken Cockrell, Pilot Mark Polansky and Mission Specialists Robert Curbeam, Thomas Jones and Marsha Ivins. The mission will be transporting the Lab to the International Space Station with five system racks already installed inside of the module. With delivery of electronics in the lab, electrically powered attitude control for Control Moment Gyroscopes will be activated. The STS-98 launch is scheduled for Jan. 18, 2001.

  7. Single qubit operations using microwave hyperbolic secant pulses

    NASA Astrophysics Data System (ADS)

    Ku, H. S.; Long, J. L.; Wu, X.; Bal, M.; Lake, R. E.; Barnes, Edwin; Economou, Sophia E.; Pappas, D. P.

    2017-10-01

    It has been known since the early days of quantum mechanics that hyperbolic secant pulses possess the unique property that they can perform full-cycle Rabi oscillations on two-level quantum systems independently of the pulse detuning. More recently, it was realized that they induce detuning-controlled phases without changing state populations. Here, we experimentally demonstrate the properties of hyperbolic secant pulses on superconducting transmon qubits and contrast them with the more commonly used Gaussian and square waves. We further show that these properties can be exploited to implement phase gates, nominally without exiting the computational subspace. This enables us to demonstrate a microwave-driven Z rotation with a single control parameter, the detuning.

  8. A Modification to the Computer Generated Acquisition Documents System (CGADS) for Microcomputer Use in a Program Office Environment.

    DTIC Science & Technology

    1985-09-01

    FILL. MOVE ALPHA-RESPONSE TO RESPONSE. 221C-RUN-TASKS-EXIT. EXIT. 2220-DISPLAY-TASK-MENU. PERFORM 5000- OETER -NISC-TASK-VALS. MOVE 1 TO ANSWER-FILE-KEY...INDEX-FIELD-2 ELSE MOVE 4 TO ANSWER-FILE-KEY SUBTRACT 200 FROM INDEX-FIELD-2. 5000- OETER -MISC-TASK-VALS. IF AREA-NUMBER a ŕ" MOVE 1 TO TASK-FILE-REC-NUM

  9. Electric field controlled emulsion phase contactor

    DOEpatents

    Scott, Timothy C.

    1995-01-01

    A system for contacting liquid phases comprising a column for transporting a liquid phase contacting system, the column having upper and lower regions. The upper region has a nozzle for introducing a dispersed phase and means for applying thereto a vertically oriented high intensity pulsed electric field. This electric field allows improved flow rates while shattering the dispersed phase into many micro-droplets upon exiting the nozzle to form a dispersion within a continuous phase. The lower region employs means for applying to the dispersed phase a horizontally oriented high intensity pulsed electric field so that the dispersed phase undergoes continuous coalescence and redispersion while being urged from side to side as it progresses through the system, increasing greatly the mass transfer opportunity.

  10. Method of using an electric field controlled emulsion phase contactor

    DOEpatents

    Scott, Timothy C.

    1993-01-01

    A system for contacting liquid phases comprising a column for transporting a liquid phase contacting system, the column having upper and lower regions. The upper region has a nozzle for introducing a dispersed phase and means for applying thereto a vertically oriented high intensity pulsed electric field. This electric field allows improved flow rates while shattering the dispersed phase into many micro-droplets upon exiting the nozzle to form a dispersion within a continuous phase. The lower region employs means for applying to the dispersed phase a horizontally oriented high intensity pulsed electric field so that the dispersed phase undergoes continuous coalescence and redispersion while being urged from side to side as it progresses through the system, increasing greatly the mass transfer opportunity.

  11. Electric field controlled emulsion phase contactor

    DOEpatents

    Scott, T.C.

    1995-01-31

    A system is described for contacting liquid phases comprising a column for transporting a liquid phase contacting system, the column having upper and lower regions. The upper region has a nozzle for introducing a dispersed phase and means for applying thereto a vertically oriented high intensity pulsed electric field. This electric field allows improved flow rates while shattering the dispersed phase into many micro-droplets upon exiting the nozzle to form a dispersion within a continuous phase. The lower region employs means for applying to the dispersed phase a horizontally oriented high intensity pulsed electric field so that the dispersed phase undergoes continuous coalescence and redispersion while being urged from side to side as it progresses through the system, increasing greatly the mass transfer opportunity. 5 figs.

  12. Er:YAG laser pulse for small-dose splashback-free microjet transdermal drug delivery.

    PubMed

    Park, Mi-ae; Jang, Hun-jae; Sirotkin, Fedir V; Yoh, Jack J

    2012-09-15

    The microjet injector system accelerates drugs and delivers them without a needle, which is shown to overcome the weaknesses of existing jet injectors. A significant increase in the delivered dose of drugs is reported with multiple pulses of laser beam at lower laser energy than was previously used in a Nd:YAG system. The new injection scheme uses the beam wavelength best absorbable by water at a longer pulse mode for elongated microjet penetration into a skin target. A 2.9 μm Er:YAG laser at 250 μs pulse duration is used for fluorescent staining of guinea pig skin and for injection controllability study. Hydrodynamic theory confirms the nozzle exit jet velocity obtained by the present microjet system.

  13. Cardiovascular disease, diabetes and early exit from paid employment in Europe; the impact of work-related factors.

    PubMed

    Kouwenhoven-Pasmooij, T A; Burdorf, A; Roos-Hesselink, J W; Hunink, M G M; Robroek, S J W

    2016-07-15

    The aims of the study were to examine (i) the association between cardiovascular disease (CVD) or diabetes and exit from paid employment via disability benefits, unemployment, early retirement or other exit routes; and (ii) the impact of work-related factors on exit from paid employment among individuals with CVD or diabetes. Respondents of the longitudinal Survey of Health and Retirement in Europe (SHARE) were included if they were aged >50years, had paid employment at baseline, and a known employment status after 2 or 6years (n=5182). A baseline-interview provided information on the presence of diagnosed CVD and diabetes, and physical and psychosocial work-related factors. During follow-up interviews information on work status was collected. Multinomial regression analyses were used to investigate the association between CVD, diabetes and exit from paid employment, and the impact of work-related factors. Workers with CVD or diabetes had significantly increased probabilities of disability benefits (OR 2.50, 95% CI 1.69-3.70) and early retirement (OR 1.34, 95% CI 1.05-1.74), but a comparable probability of unemployment (OR 1.10, 95% CI 0.71-1.71). Regarding disability benefits, individuals who had a stroke had the highest probability (OR 3.48, 95% CI 1.31-9.23). Perceived high job demands with low rewards or with low control at work further increased the probability of early exit among individuals with CVD or diabetes. Our study shows a prominent role of CVD and diabetes in premature losses to the workforce, and it shows that optimizing psychosocial work-related factors could be beneficial in people with CVD or diabetes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Differences in the neural correlates of frontal lobe tests.

    PubMed

    Matsuoka, Teruyuki; Kato, Yuka; Imai, Ayu; Fujimoto, Hiroshi; Shibata, Keisuke; Nakamura, Kaeko; Yamada, Kei; Narumoto, Jin

    2018-01-01

    The Executive Interview (EXIT25), the executive clock-drawing task (CLOX1), and the Frontal Assessment Battery (FAB) are used to assess executive function at the bedside. These tests assess distinct psychometric properties. The aim of this study was to examine differences in the neural correlates of the EXIT25, CLOX1, and FAB based on magnetic resonance imaging. Fifty-eight subjects (30 with Alzheimer's disease, 10 with mild cognitive impairment, and 18 healthy controls) participated in this study. Multiple regression analyses were performed to examine the brain regions correlated with the EXIT25, CLOX1, and FAB scores. Age, gender, and years of education were included as covariates. Statistical thresholds were set to uncorrected P-values of 0.001 at the voxel level and 0.05 at the cluster level. The EXIT25 score correlated inversely with the regional grey matter volume in the left lateral frontal lobe (Brodmann areas 6, 9, 44, and 45). The CLOX1 score correlated positively with the regional grey matter volume in the right orbitofrontal cortex (Brodmann area 11) and the left supramarginal gyrus (Brodmann area 40). The FAB score correlated positively with the regional grey matter volume in the right precentral gyrus (Brodmann area 6). The left lateral frontal lobe (Brodmann area 9) and the right lateral frontal lobe (Brodmann area 46) were identified as common brain regions that showed association with EXIT25, CLOX1, and FAB based only a voxel-level threshold. The results of this study suggest that the EXIT25, CLOX1, and FAB may be associated with the distinct neural correlates of the frontal cortex. © 2018 Japanese Psychogeriatric Society.

  15. Breakup phenomena of a coaxial jet in the non-dilute region using real-time X-ray radiography

    NASA Astrophysics Data System (ADS)

    Cheung, F. B.; Kuo, K. K.; Woodward, R. D.; Garner, K. N.

    1990-07-01

    An innovative approach to the investigation of liquid jet breakup processes in the near-injector region has been developed to overcome the experimental difficulties associated with optically opaque, dense sprays. Real-time X-ray radiography (RTR) has been employed to observe the inner structure and breakup phenomena of coaxial jets. In the atomizing regime, droplets much smaller than the exit diameter are formed beginning essentially at the injector exit. Through the use of RTR, the instantaneous contour of the liquid core was visualized. Experimental results consist of controlled-exposure digital video images of the liquid jet breakup process. Time-averaged video images have also been recorded for comparison. A digital image processing system is used to analyze the recorded images by creating radiance level distributions of the jet. A rudimentary method for deducing intact-liquid-core length has been suggested. The technique of real-time X-ray radiography has been shown to be a viable approach to the study of the breakup processes of high-speed liquid jets.

  16. Ambulatory surgery center and general hospital competition: entry decisions and strategic choices.

    PubMed

    Al-Amin, Mona; Housman, Michael

    2012-01-01

    General hospitals are consistently under pressure to control cost and improve quality. In addition to mounting payers' demands, hospitals operate under evolving market conditions that might threaten their survival. While hospitals traditionally were concerned mainly with competition from other hospitals, today's reimbursement schemes and entrepreneurial activities encouraged the proliferation of outpatient facilities such as ambulatory surgery centers (ASCs) that can jeopardize hospitals' survival. The purpose of this article was to examine the relationship between ASCs and general hospitals. More specifically, we apply the niche overlap theory to study the impact that competition between ASCs and general hospitals has on the survival chances of both of these organizational populations. Our analysis examined interpopulation competition in models of organizational mortality and market demand. We utilized Cox proportional hazard models to evaluate the impact of competition from each on ASC and hospital exit while controlling for market factors. We relied on two data sets collected and developed by Florida's Agency for Health Care Administration: outpatient facility licensure data and inpatient and outpatient surgical procedure data. Although ASCs do tend to exit markets in which there are high levels of ASC competition, we found no evidence to suggest that ASC exit rates are affected by hospital density. On the other hand, hospitals not only tend to exit markets with high levels of hospital competition but also experience high exit rates in markets with high ASC density. The implications from our study differ for ASCs and hospitals. When making decisions about market entry, ASCs should choose their markets according to the following: demand for outpatient surgery, number of physicians who would practice in the surgery center, and the number of surgery centers that already exist in the market. Hospitals, on the other hand, should account for competition from ASCs while making market-entry decisions and while developing their strategic plans.

  17. Tritium monitor and collection system

    DOEpatents

    Bourne, G.L.; Meikrantz, D.H.; Ely, W.E.; Tuggle, D.G.; Grafwallner, E.G.; Wickham, K.L.; Maltrud, H.R.; Baker, J.D.

    1992-01-14

    This system measures tritium on-line and collects tritium from a flowing inert gas stream. It separates the tritium from other non-hydrogen isotope contaminating gases, whether radioactive or not. The collecting portion of the system is constructed of various zirconium alloys called getters. These alloys adsorb tritium in any of its forms at one temperature and at a higher temperature release it as a gas. The system consists of four on-line getters and heaters, two ion chamber detectors, two collection getters, and two guard getters. When the incoming gas stream is valved through the on-line getters, 99.9% of it is adsorbed and the remainder continues to the guard getter where traces of tritium not collected earlier are adsorbed. The inert gas stream then exits the system to the decay chamber. Once the on-line getter has collected tritium for a predetermined time, it is valved off and the next on-line getter is valved on. Simultaneously, the first getter is heated and a pure helium purge is employed to carry the tritium from the getter. The tritium loaded gas stream is then routed through an ion chamber which measures the tritium activity. The ion chamber effluent passes through a collection getter that readsorbs the tritium and is removable from the system once it is loaded and is then replaced with a clean getter. Prior to removal of the collection getter, the system switches to a parallel collection getter. The effluent from the collection getter passes through a guard getter to remove traces of tritium prior to exiting the system. The tritium loaded collection getter, once removed, is analyzed by liquid scintillation techniques. The entire sequence is under computer control except for the removal and analysis of the collection getter. 7 figs.

  18. Exit probability of the one-dimensional q-voter model: Analytical results and simulations for large networks

    NASA Astrophysics Data System (ADS)

    Timpanaro, André M.; Prado, Carmen P. C.

    2014-05-01

    We discuss the exit probability of the one-dimensional q-voter model and present tools to obtain estimates about this probability, both through simulations in large networks (around 107 sites) and analytically in the limit where the network is infinitely large. We argue that the result E(ρ )=ρq/ρq+(1-ρ)q, that was found in three previous works [F. Slanina, K. Sznajd-Weron, and P. Przybyła, Europhys. Lett. 82, 18006 (2008), 10.1209/0295-5075/82/18006; R. Lambiotte and S. Redner, Europhys. Lett. 82, 18007 (2008), 10.1209/0295-5075/82/18007, for the case q =2; and P. Przybyła, K. Sznajd-Weron, and M. Tabiszewski, Phys. Rev. E 84, 031117 (2011), 10.1103/PhysRevE.84.031117, for q >2] using small networks (around 103 sites), is a good approximation, but there are noticeable deviations that appear even for small systems and that do not disappear when the system size is increased (with the notable exception of the case q =2). We also show that, under some simple and intuitive hypotheses, the exit probability must obey the inequality ρq/ρq+(1-ρ)≤E(ρ)≤ρ/ρ +(1-ρ)q in the infinite size limit. We believe this settles in the negative the suggestion made [S. Galam and A. C. R. Martins, Europhys. Lett. 95, 48005 (2001), 10.1209/0295-5075/95/48005] that this result would be a finite size effect, with the exit probability actually being a step function. We also show how the result that the exit probability cannot be a step function can be reconciled with the Galam unified frame, which was also a source of controversy.

  19. Training Parents of Youth with Autism Spectrum Disorder to Advocate for Adult Disability Services: Results from a Pilot Randomized Controlled Trial

    PubMed Central

    Taylor, Julie Lounds; Hodapp, Robert M.; Burke, Meghan M.; Waitz-Kudla, Sydney N.; Rabideau, Carol

    2017-01-01

    This study presents findings from a pilot randomized controlled trial, testing a 12-week intervention to train parents of youth with autism spectrum disorder (ASD) to advocate for adult disability services—the Volunteer Advocacy Project-Transition (VAP-T). Participants included 41 parents of youth with ASD within two years of high school exit, randomly assigned to a treatment (N = 20) or wait-list control (N = 21) group. Outcomes, collected before and after the intervention, included parental knowledge about adult services, advocacy skills-comfort, and empowerment. The VAP-T had acceptable feasibility, treatment fidelity, and acceptability. After participating in the VAP-T, intervention parents (compared to controls) knew more about the adult service system, were more skilled/comfortable advocating, and felt more empowered. PMID:28070786

  20. Terminal-shock and restart control of a Mach 2.5, axisymmetric, mixed compression inlet with 40 percent internal contraction. [wind tunnel tests

    NASA Technical Reports Server (NTRS)

    Baumbick, R. J.

    1974-01-01

    Results of experimental tests conducted on a supersonic, mixed-compression, axisymmetric inlet are presented. The inlet is designed for operation at Mach 2.5 with a turbofan engine (TF-30). The inlet was coupled to either a choked orifice plate or a long duct which had a variable-area choked exit plug. Closed-loop frequency responses of selected diffuser static pressures used in the terminal-shock control system are presented. Results are shown for Mach 2.5 conditions with the inlet coupled to either the choked orifice plate or the long duct. Inlet unstart-restart traces are also presented. High-response inlet bypass doors were used to generate an internal disturbance and also to achieve terminal-shock control.

  1. Randomized Trial of Intensive Housing Placement and Community Transition Services for Episodic and Recidivist Homeless Families

    PubMed Central

    Mitchell, Kristen; Pareti, Lauren; DeGenova, Joe; Heller, Anne; Hannigan, Anthony; Gholston, Jennifer

    2013-01-01

    Objectives. We compared Home to Stay, a pilot of intensive housing placement and community transition services for episodic and recidivist homeless families, with a standard services approach. Methods. Using intention-to-treat analyses, we conducted a modified randomized trial of 138 Home to Stay client families and a control group of 192 client families receiving standard shelter services. Results. Home to Stay clients exited shelter more quickly than clients in the control group (Cox regression, P < .001), more commonly exited shelter with housing subsidies (75% vs 56%), stayed out of shelter longer (Cox regression, P = .011), and spent fewer total days in shelter (376 days vs 449 days). Home to Stay performed best with clients who entered shelter within 180 days of the pilot’s start date and had less impact on clients entering shelter before that time. Conclusions. Relative to standard services, Home to Stay services can accelerate exit from shelter and reduce return to shelter and total sheltered days for episodic and recidivist homeless families. Standard shelter services may be able to narrow this performance gap by incentivizing work with all episodic and recidivist homeless families. PMID:24148053

  2. Should we pay the student? A randomised trial of financial incentives in medical education.

    PubMed

    Raupach, Tobias; Brown, Jamie; Wieland, Anna; Anders, Sven; Harendza, Sigrid

    2013-09-01

    Financial incentives are effective in moderating physician and patient behaviour, but they have not been studied in the context of medical education. This study assessed whether financial incentives can motivate students to acquire electrocardiogram (ECG) interpretation skills. Students enrolled for a cardio-respiratory teaching module (n = 121) were randomised to an intervention (financial incentive) or a control (book voucher raffle) condition. All students took three validated exams of ECG interpretation skills (at module entry, module exit and seven weeks later). Only the exit exam was financially incentivised in the intervention group. The primary outcome was the proportion of students who correctly identified ≥60% of clinically important diagnoses in the exit exam. Financial incentives more than doubled the odds of correctly identifying ≥60% of diagnoses in the exit exam (adjusted odds ratio 2.44, 95% confidence interval 1.05-5.67) and significantly increased student learning time. However, there was no significant effect on performance levels in the retention exam. Financial incentives increase reported learning time and examination results in the short-term. The lack of a sustained effect on performance suggests that financial incentives may foster a superficial or strategic rather than a deep approach to learning.

  3. Cdc15 integrates Tem1 GTPase-mediated spatial signals with Polo kinase-mediated temporal cues to activate mitotic exit.

    PubMed

    Rock, Jeremy M; Amon, Angelika

    2011-09-15

    In budding yeast, a Ras-like GTPase signaling cascade known as the mitotic exit network (MEN) promotes exit from mitosis. To ensure the accurate execution of mitosis, MEN activity is coordinated with other cellular events and restricted to anaphase. The MEN GTPase Tem1 has been assumed to be the central switch in MEN regulation. We show here that during an unperturbed cell cycle, restricting MEN activity to anaphase can occur in a Tem1 GTPase-independent manner. We found that the anaphase-specific activation of the MEN in the absence of Tem1 is controlled by the Polo kinase Cdc5. We further show that both Tem1 and Cdc5 are required to recruit the MEN kinase Cdc15 to spindle pole bodies, which is both necessary and sufficient to induce MEN signaling. Thus, Cdc15 functions as a coincidence detector of two essential cell cycle oscillators: the Polo kinase Cdc5 synthesis/degradation cycle and the Tem1 G-protein cycle. The Cdc15-dependent integration of these temporal (Cdc5 and Tem1 activity) and spatial (Tem1 activity) signals ensures that exit from mitosis occurs only after proper genome partitioning.

  4. Mechanisms of copper homeostasis in bacteria

    PubMed Central

    Argüello, José M.; Raimunda, Daniel; Padilla-Benavides, Teresita

    2013-01-01

    Copper is an important micronutrient required as a redox co-factor in the catalytic centers of enzymes. However, free copper is a potential hazard because of its high chemical reactivity. Consequently, organisms exert a tight control on Cu+ transport (entry-exit) and traffic through different compartments, ensuring the homeostasis required for cuproprotein synthesis and prevention of toxic effects. Recent studies based on biochemical, bioinformatics, and metalloproteomics approaches, reveal a highly regulated system of transcriptional regulators, soluble chaperones, membrane transporters, and target cuproproteins distributed in the various bacterial compartments. As a result, new questions have emerged regarding the diversity and apparent redundancies of these components, their irregular presence in different organisms, functional interactions, and resulting system architectures. PMID:24205499

  5. An Overview of Atmospheric Fluidized Bed Combustion Systems as Applied to Army Scale Central Heat Plants

    DTIC Science & Technology

    1992-11-01

    heat transfer surfaces located in the path of the exiting combustion gases generate additional steam. Flue gas particulates entrained in the combustion...anid the overall heat transfer surface anid boiler volume can be reduced. After the hot flue gas exits thie bed, it enters the external COnv.ctfion...rates, underfeed stoker fired combustors emit little smoke, and only a low concentration of particulates entrained in the flue gas . Under these

  6. Controlled Expansion of Supercritical Solution: A Robust Method to Produce Pure Drug Nanoparticles With Narrow Size-Distribution.

    PubMed

    Pessi, Jenni; Lassila, Ilkka; Meriläinen, Antti; Räikkönen, Heikki; Hæggström, Edward; Yliruusi, Jouko

    2016-08-01

    We introduce a robust, stable, and reproducible method to produce nanoparticles based on expansion of supercritical solutions using carbon dioxide as a solvent. The method, controlled expansion of supercritical solution (CESS), uses controlled mass transfer, flow, pressure reduction, and particle collection in dry ice. CESS offers control over the crystallization process as the pressure in the system is reduced according to a specific profile. Particle formation takes place before the exit nozzle, and condensation is the main mechanism for postnucleation particle growth. A 2-step gradient pressure reduction is used to prevent Mach disk formation and particle growth by coagulation. Controlled particle growth keeps the production process stable. With CESS, we produced piroxicam nanoparticles, 60 mg/h, featuring narrow size distribution (176 ± 53 nm). Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  7. Internet Delivered Support for Tobacco Control in Dental Practice: Randomized Controlled Trial

    PubMed Central

    Richman, Joshua S; Ray, Midge N; Allison, Jeroan J; Gilbert, Gregg H; Shewchuk, Richard M; Kohler, Connie L; Kiefe, Catarina I

    2008-01-01

    Background The dental visit is a unique opportunity for tobacco control. Despite evidence of effectiveness in dental settings, brief provider-delivered cessation advice is underutilized. Objective To evaluate an Internet-delivered intervention designed to increase implementation of brief provider advice for tobacco cessation in dental practice settings. Methods Dental practices (N = 190) were randomized to the intervention website or wait-list control. Pre-intervention and after 8 months of follow-up, each practice distributed exit cards (brief patient surveys assessing provider performance, completed immediately after the dental visit) to 100 patients. Based on these exit cards, we assessed: whether patients were asked about tobacco use (ASK) and, among tobacco users, whether they were advised to quit tobacco (ADVISE). All intervention practices with follow-up exit card data were analyzed as randomized regardless of whether they participated in the Internet-delivered intervention. Results Of the 190 practices randomized, 143 (75%) dental practices provided follow-up data. Intervention practices’ mean performance improved post-intervention by 4% on ASK (29% baseline, adjusted odds ratio = 1.29 [95% CI 1.17-1.42]), and by 11% on ADVISE (44% baseline, OR = 1.55 [95% CI 1.28-1.87]). Control practices improved by 3% on ASK (Adj. OR 1.18 [95% CI 1.07-1.29]) and did not significantly improve in ADVISE. A significant group-by-time interaction effect indicated that intervention practices improved more over the study period than control practices for ADVISE (P = 0.042) but not for ASK. Conclusion This low-intensity, easily disseminated intervention was successful in improving provider performance on advice to quit. Trial Registration clinicaltrials.gov NCT00627185; http://clinicaltrials.gov/ct2/show/NCT00627185 (Archived by WebCite at http://www.webcitation.org/5c5Kugvzj) PMID:18984559

  8. Evaluating best practices for Campylobacter and Salmonella reduction in poultry processing plants.

    PubMed

    Wideman, N; Bailey, M; Bilgili, S F; Thippareddi, H; Wang, L; Bratcher, C; Sanchez-Plata, M; Singh, M

    2016-02-01

    Poultry processing plants in the United States were surveyed on their current Campylobacter and Salmonella control practices. Following surveys, data were collected to develop a baseline for prevalence rates of Salmonella and Campylobacter; then changes in practices were implemented and evaluated for improvements in pathogen control. Surveys were sent to the plant Quality Assurance managers to determine production levels, antimicrobial interventions, and current pathogen testing practices. Initial sampling was performed at 6 plants with similar production volumes, at sites that included carcass samples before any pre-evisceration intervention, after exiting the inside-outside bird washer (IOBW), after exiting the pre-chiller, after exiting the primary chiller, and after exiting any post-chill intervention, as well as a water sample from each scalder, pre-chiller, primary chiller, and post-chill dip tank or finishing chiller. Enumerations and enrichments were performed for Campylobacter and Salmonella. Following the baseline sampling, changes in practices were suggested for each plant and a second sampling was conducted to determine their effectiveness. Results demonstrated that peracetic acid (PAA) was the most effective (P < 0.05) antimicrobial currently in use. The use of a post-chill antimicrobial immersion tank and/or use of a cetylpyridinium chloride (CPC) spray cabinet also displayed a further reduction in microbial levels (P < 0.05) when the primary chiller was not sufficient (P > 0.05). Microbial buildup in the immersion tanks demonstrates the need for effective cleaning, sanitation practices, and chiller maintenance to reduce contamination of poultry with Campylobacter and Salmonella. © 2015 Poultry Science Association Inc.

  9. Dynamically variable spot size laser system

    NASA Technical Reports Server (NTRS)

    Gradl, Paul R. (Inventor); Hurst, John F. (Inventor); Middleton, James R. (Inventor)

    2012-01-01

    A Dynamically Variable Spot Size (DVSS) laser system for bonding metal components includes an elongated housing containing a light entry aperture coupled to a laser beam transmission cable and a light exit aperture. A plurality of lenses contained within the housing focus a laser beam from the light entry aperture through the light exit aperture. The lenses may be dynamically adjusted to vary the spot size of the laser. A plurality of interoperable safety devices, including a manually depressible interlock switch, an internal proximity sensor, a remotely operated potentiometer, a remotely activated toggle and a power supply interlock, prevent activation of the laser and DVSS laser system if each safety device does not provide a closed circuit. The remotely operated potentiometer also provides continuous variability in laser energy output.

  10. Takeover Time in Highly Automated Vehicles: Noncritical Transitions to and From Manual Control.

    PubMed

    Eriksson, Alexander; Stanton, Neville A

    2017-06-01

    The aim of this study was to review existing research into driver control transitions and to determine the time it takes drivers to resume control from a highly automated vehicle in noncritical scenarios. Contemporary research has moved from an inclusive design approach to adhering only to mean/median values when designing control transitions in automated driving. Research into control transitions in highly automated driving has focused on urgent scenarios where drivers are given a relatively short time span to respond to a request to resume manual control. We found a paucity in research into more frequent scenarios for control transitions, such as planned exits from highway systems. Twenty-six drivers drove two scenarios with an automated driving feature activated. Drivers were asked to read a newspaper, or to monitor the system, and to relinquish, or resume, control from the automation when prompted by vehicle systems. Significantly longer control transition times were found between driving with and without secondary tasks. Control transition times were substantially longer than those reported in the peer-reviewed literature. We found that drivers take longer to resume control when under no time pressure compared with that reported in the literature. Moreover, we found that drivers occupied by a secondary task exhibit larger variance and slower responses to requests to resume control. Workload scores implied optimal workload. Intra- and interindividual differences need to be accommodated by vehicle manufacturers and policy makers alike to ensure inclusive design of contemporary systems and safety during control transitions.

  11. A patient mobility framework that travels: European and United States-Mexican comparisons.

    PubMed

    Laugesen, Miriam J; Vargas-Bustamante, Arturo

    2010-10-01

    To develop a framework that parsimoniously explains divergent patient mobility in the United States and Europe. Review of studies of patient mobility; data from the 2007 Flash Eurobarometer and the 2001 California Health Interview Survey was analyzed; and we reviewed government policies and documents in the United States and Europe. Four types of patient mobility are defined: primary, complementary, duplicative, and institutionalized. Primary exit occurs when people without comprehensive insurance travel because they cannot afford to pay for health insurance or directly finance care, as in the United States and Mexico. Second, people will exit to buy complementary services not covered, or partially covered by domestic health insurance, in both the United States and Europe. Third, in Europe, patient mobility for duplicative services provides faster or better quality treatment. Finally, governments and insurers can encourage institutionalized exit through expanded delivery options and financing. Institutionalized exit is developing in Europe, but uncoordinated and geographically limited in the United States. This parsimonious framework explains patient mobility by considering domestic health system characteristics relating to cost and quality. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  12. A passive RFID-based location system for personnel and asset monitoring.

    PubMed

    Hsiao, Rong-Shue; Kao, Chun-Hao; Chen, Tian-Xiang; Chen, Jui-Lun

    2018-01-01

    Typical radio frequency identification (RFID) access control system can be ineffective if an unauthorized person tailgates an authorized person through an access area. To propose a system by using indoor locating and tracking techniques address this problem, which is to prevent unauthorized Alzheimer's and dementia patients from getting lost including by tailgating. To achieve accurate target location, passive RFID deployment strategy is studied and a fingerprinting based passive RFID localization algorithm is proposed. The proposed system was evaluated in a building environment to simulate the performance of access control. RFID reader was installed on ceiling near the access area and tags were stitched on both shoulders of the experiment subject's garments. The probability of the error distance within 0.3 m achieved 97% in the warning area; the location precision achieved 97% within 0.4 m in the monitoring area. The result showed that if an unauthorized person enters the restricted area, the system can initiate an alert signal accurately. Therefore, the proposed system is very suitable to be used in nursing home or hospital to prevent unauthorized personnel and assets entering/exiting a confined location.

  13. Effects of temperament and acclimation to handling on reproductive performance of Bos taurus beef females.

    PubMed

    Cooke, R F; Bohnert, D W; Cappellozza, B I; Mueller, C J; Delcurto, T

    2012-10-01

    Two experiments evaluated the effects of temperament and acclimation to handling on reproductive performance of Bos taurus beef females. In Exp. 1, 433 multiparous, lactating Angus × Hereford cows were sampled for blood and evaluated for temperament before the breeding season. Cow temperament was assessed by chute score and exit velocity. Chute score was assessed on a 5-point scale according to behavioral responses during chute restraining. Exit score was calculated by dividing exit velocity into quintiles and assigning cows with a score from 1 to 5 (1 = slowest, 5 = fastest cows). Temperament score was calculated by averaging chute and exit scores. Cows were classified for temperament type according to temperament score (≤ 3 = adequate, > 3 = aggressive). Plasma cortisol concentrations were greater (P < 0.01) in cows with aggressive vs. adequate temperament. Cows with aggressive temperament had reduced (P ≤ 0.05) pregnancy and calving rate and tended to have reduced (P = 0.09) weaning rate compared with cows with adequate temperament. Hence, kilogram of calf born per cow was reduced (P = 0.05) and kilogram of calf weaned per cow tended to be reduced (P = 0.08) in aggressive cows. In Exp. 2, 88 Angus × Hereford heifers (initial age = 206 ± 2 d) were weighed (d 0 and 10) and evaluated for temperament score (d 10). On d 11, heifers were ranked by these variables and assigned to receive or not (control) an acclimation treatment. Acclimated heifers were processed through a handling facility 3 times weekly for 4 wk (d 11 to 39; Mondays, Wednesdays, and Fridays), whereas control heifers remained undisturbed on pasture. Heifer puberty status, evaluated via plasma progesterone concentrations, was assessed on d 0 and 10, d 40 and 50, 70 and 80, 100 and 110, 130 and 140, 160 and 170, and 190 and 200. Blood samples collected on d 10 and 40 were also analyzed for plasma concentrations of cortisol and haptoglobin. Temperament score was assessed again on d 40 and d 200. Acclimated heifers had reduced (P = 0.01) concentrations of cortisol and haptoglobin on d 40 and reduced (P = 0.02) exit velocity on d 200 compared with control heifers. Puberty was hastened in acclimated heifers compared with control (P = 0.01). Results from this study indicate that B. taurus beef cows with aggressive temperament have impaired reproductive performance compared with cohorts with adequate temperament, whereas acclimation to human handling after weaning hastens reproductive development of replacement heifers.

  14. Partially integrated exhaust manifold

    DOEpatents

    Hayman, Alan W; Baker, Rodney E

    2015-01-20

    A partially integrated manifold assembly is disclosed which improves performance, reduces cost and provides efficient packaging of engine components. The partially integrated manifold assembly includes a first leg extending from a first port and terminating at a mounting flange for an exhaust gas control valve. Multiple additional legs (depending on the total number of cylinders) are integrally formed with the cylinder head assembly and extend from the ports of the associated cylinder and terminate at an exit port flange. These additional legs are longer than the first leg such that the exit port flange is spaced apart from the mounting flange. This configuration provides increased packaging space adjacent the first leg for any valving that may be required to control the direction and destination of exhaust flow in recirculation to an EGR valve or downstream to a catalytic converter.

  15. Design, fabrication and acoustic tests of a 36 inch (0.914 meter) statorless turbotip fan

    NASA Technical Reports Server (NTRS)

    Smith, E. G.; Stempert, D. L.; Uhl, W. R.

    1975-01-01

    The LF336/E is a 36 inch (0.914 meter) diameter fan designed to operate in a rotor-alone configuration. Design features required for modification of the existing LF336/A rotor-stator fan into the LF336/E statorless fan configuration are discussed. Tests of the statorless fan identified an aerodynamic performance deficiency due to inaccurate accounting of the fan exit swirl during the aerodynamic design. This performance deficiency, related to fan exit static pressure levels, produced about a 20 percent thrust loss. A study was then conducted for further evaluation of the fan exit flow fields typical of statorless fan systems. This study showed that through proper selection of fan design variables such as pressure ratio, radius ratio, and swirl distributions, performance of a statorless fan configuration could be improved with levels of thrust approaching the conventional rotor-stator fan system. Acoustic measurements were taken for the statorless fan system at both GE and NASA, and when compared to other lift fan systems, showed noise levels comparable to the quietest lift fan configuration which included rotor-stator spacing and acoustic treatment. The statorless fan system was also used to determine effects of rotor leading edge serrations on noise generations. A cascade test program identified the serration geometry based on minimum pressure losses, wake turbulence levels and noise generations.

  16. The problem of the driverless vehicle specified path stability control

    NASA Astrophysics Data System (ADS)

    Buznikov, S. E.; Endachev, D. V.; Elkin, D. S.; Strukov, V. O.

    2018-02-01

    Currently the effort of many leading foreign companies is focused on creation of driverless transport for transportation of cargo and passengers. Among many practical problems arising while creating driverless vehicles, the problem of the specified path stability control occupies a central place. The purpose of this paper is formalization of the problem in question in terms of the quadratic functional of the control quality, the comparative analysis of the possible solutions and justification of the choice of the optimum technical solution. As square value of the integral of the deviation from the specified path is proposed as the quadratic functional of the control quality. For generation of the set of software and hardware solution variants the Zwicky “morphological box” method is used within the hardware and software environments. The heading control algorithms use the wheel steering angle data and the deviation from the lane centerline (specified path) calculated based on the navigation data and the data from the video system. Where the video system does not detect the road marking, the control is carried out based on the wheel navigation system data and where recognizable road marking exits - based on to the video system data. The analysis of the test results allows making the conclusion that the application of the combined navigation system algorithms that provide quasi-optimum solution of the problem while meeting the strict functional limits for the technical and economic indicators of the driverless vehicle control system under development is effective.

  17. High Velocity Linear Induction Launcher with Exit-Edge Compensation for Testing of Aerospace Components

    NASA Technical Reports Server (NTRS)

    Kuznetsov, Stephen; Marriott, Darin

    2008-01-01

    Advances in ultra high speed linear induction electromagnetic launchers over the past decade have focused on magnetic compensation of the exit and entry-edge transient flux wave to produce efficient and compact linear electric machinery. The paper discusses two approaches to edge compensation in long-stator induction catapults with typical end speeds of 150 to 1,500 m/s. In classical linear induction machines, the exit-edge effect is manifest as two auxiliary traveling waves that produce a magnetic drag on the projectile and a loss of magnetic flux over the main surface of the machine. In the new design for the Stator Compensated Induction Machine (SCIM) high velocity launcher, the exit-edge effect is nulled by a dual wavelength machine or alternately the airgap flux is peaked at a location prior to the exit edge. A four (4) stage LIM catapult is presently being constructed for 180 m/s end speed operation using double-sided longitudinal flux machines. Advanced exit and entry edge compensation is being used to maximize system efficiency, and minimize stray heating of the reaction armature. Each stage will output approximately 60 kN of force and produce over 500 G s of acceleration on the armature. The advantage of this design is there is no ablation to the projectile and no sliding contacts, allowing repeated firing of the launcher without maintenance of any sort. The paper shows results of a parametric study for 500 m/s and 1,500 m/s linear induction launchers incorporating two of the latest compensation techniques for an air-core stator primary and an iron-core primary winding. Typical thrust densities for these machines are in the range of 150 kN/sq.m. to 225 kN/sq.m. and these compete favorably with permanent magnet linear synchronous machines. The operational advantages of the high speed SCIM launcher are shown by eliminating the need for pole-angle position sensors as would be required by synchronous systems. The stator power factor is also improved.

  18. AN/SLQ-32 EW System Model: and Expandable, Object-Oriented, Process- Based Simulation

    DTIC Science & Technology

    1992-09-01

    CONST threshold = 0.1; timetol = 0.01; orientol = 5.8; VAR rec, recLast :BufferBeamRecType; time,power : REAL; powerl,orientation : REAL; BEGIN NEW...PulseGroup); rec:-ASK BufferBeam Removed; time: =rec. time; orientation: =rec. orientation; OUTPUT ( "ORIENREFI, orientation); recLast :=ASK BufferBeam Last...TO Add(rec); IF (rec= recLast ) EXIT; END IF; rec :=ASK BufferBeam Remove o; ELSE ASK BufferBeam TO Add(rec); IF (rec = recLast ) EXIT; END IF; rec

  19. Stagnation point reverse flow combustor for a combustion system

    NASA Technical Reports Server (NTRS)

    Zinn, Ben T. (Inventor); Neumeier, Yedidia (Inventor); Seitzman, Jerry M. (Inventor); Jagoda, Jechiel (Inventor); Hashmonay, Ben-Ami (Inventor)

    2007-01-01

    A combustor assembly includes a combustor vessel having a wall, a proximate end defining an opening and a closed distal end opposite said proximate end. A manifold is carried by the proximate end. The manifold defines a combustion products exit. The combustion products exit being axially aligned with a portion of the closed distal end. A plurality of combustible reactant ports is carried by the manifold for directing combustible reactants into the combustion vessel from the region of the proximate end towards the closed distal end.

  20. Numerical Simulations of Flowfields in a Central-Dump Ramjet Combustor. 3. Effects of Chemistry

    DTIC Science & Technology

    1990-07-23

    conditions [1,8]. The choked outflow conditions force the flow to become sonic at the throat of the exit nozzle. The choked outflow conditions force...are realistic because under most operating conditions in practical systems, the flow is choked at the throat of the exit nozzle. Furthermore, it has...timesteps in the early stages of the reactive flow case. The mixture is ignited at the end of timestep 160000. sTrEP .I070 160000 -Z ~ ~ - 36 828

  1. Space shuttle orbiter rear mounted reaction control system jet interaction study. [hypersonic wind tunnel tests

    NASA Technical Reports Server (NTRS)

    Rausch, J. R.

    1977-01-01

    The effect of interaction between the reaction control system (RCS) jets and the flow over the space shuttle orbiter in the atmosphere was investigated in the NASA Langley 31-inch continuous flow hypersonic tunnel at a nominal Mach number of 10.3 and in the AEDC continuous flow hypersonic tunnel B at a nominal Mach number of 6, using 0.01 and .0125 scale force models with aft RCS nozzles mounted both on the model and on the sting of the force model balance. The data show that RCS nozzle exit momentum ratio is the primary correlating parameter for effects where the plume impinges on an adjacent surface and mass flow ratio is the parameter when the plume interaction is primarily with the external stream. An analytic model of aft mounted RCS units was developed in which the total reaction control moments are the sum of thrust, impingement, interaction, and cross-coupling terms.

  2. 29 CFR 1917.122 - Employee exits.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Employee exits. 1917.122 Section 1917.122 Labor Regulations...) MARINE TERMINALS Terminal Facilities § 1917.122 Employee exits. (a) Employee exits shall be clearly marked. (b) If an employee exit is not visible from employees' work stations, directional signs...

  3. Advanced Diesel Oil Fuel Processor Development

    DTIC Science & Technology

    1986-06-01

    water exit 29 sample quencher: gas sample line inlet 30 sample quencher: gas sample line exit 31 sample quencher: cooling water inlet 32 desulfuriser ...exit line 33, 34 desulfurimer 35 heat exchanger: process gas exit (to desulfuriser ) 38 shift reactor inlet (top) 37 shift reactor: cooling air exit

  4. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    PubMed

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  5. Spray forming polymer membranes, coatings and films

    DOEpatents

    McHugh, Kevin M.; Watson, Lloyd D.; McAtee, Richard E.; Ploger, Scott A.

    1993-01-01

    A method of forming a polymer film having controlled physical and chemical characteristics, wherein a plume of nebulized droplets of a polymer or polymer precursor is directed toward a substrate from a converging/diverging nozzle having a throat at which the polymer or a precursor thereof is introduced and an exit from which the nebulized droplets of the polymer or precursor thereof leave entrained in a carrier gas. Relative movement between the nozzle and the substrate is provided to form a polymer film. Physical and chemical characteristics can be controlled by varying the deposition parameters and the gas and liquid chemistries. Semipermeable membranes of polyphosphazene films are disclosed, as are a variety of other polymer systems, both porous and non-porous.

  6. Spray forming polymer membranes, coatings and films

    DOEpatents

    McHugh, K.M.; Watson, L.D.; McAtee, R.E.; Ploger, S.A.

    1993-10-12

    A method is described for forming a polymer film having controlled physical and chemical characteristics, wherein a plume of nebulized droplets of a polymer or polymer precursor is directed toward a substrate from a converging/diverging nozzle having a throat at which the polymer or a precursor thereof is introduced and an exit from which the nebulized droplets of the polymer or precursor thereof leave entrained in a carrier gas. Relative movement between the nozzle and the substrate is provided to form a polymer film. Physical and chemical characteristics can be controlled by varying the deposition parameters and the gas and liquid chemistries. Semipermeable membranes of polyphosphazene films are disclosed, as are a variety of other polymer systems, both porous and non-porous. 4 figures.

  7. Future Image of Graduate Education in Japan

    NASA Astrophysics Data System (ADS)

    Kai, Shoichi

    On substance of graduate school education it is an important factor to clarify the difference between an academic degree and professional degree in engineering fields, as well as the difference between master and doctor degree, and the ability that the degree guarantees. In order to achieve it, the target and aim of talented person education under the corresponding degree must be clearly shown, and the development of a proper curriculum and a new system for the graduate education are required. Based on those, to control and maintain the quality of the degree, exit (outcome) management is necessary.

  8. Lunar Reconnaissance Orbiter (LRO) Thruster Control Mode Design and Flight Experience

    NASA Technical Reports Server (NTRS)

    Hsu, Oscar C.

    2010-01-01

    National Aeronautics and Space Administration s (NASA) Goddard Space Flight Center (GSFC) in Greenbelt, MD, designed, built, tested, and launched the Lunar Reconnaissance Orbiter (LRO) from Cape Canaveral Air Force Station on June 18, 2009. The LRO spacecraft is the first operational spacecraft designed to support NASA s return to the Moon, as part of the Vision for Space Exploration. LRO was launched aboard an Atlas V 401 launch vehicle into a direct insertion trajectory to the Moon. Twenty-four hours after separation the propulsion system was used to perform a mid-course correction maneuver. Four days after the mid-course correction a series of propulsion maneuvers were executed to insert LRO into its commissioning orbit. The commission period lasted eighty days and this followed by a second set of thruster maneuvers that inserted LRO into its mission orbit. To date, the spacecraft has been gathering invaluable data in support of human s future return to the moon. The LRO Attitude Control Systems (ACS) contains two thruster based control modes: Delta-H and Delta-V. The design of the two controllers are similar in that they are both used for 3-axis control of the spacecraft with the Delta-H controller used for momentum management and the Delta-V controller used for orbit adjust and maintenance maneuvers. In addition to the nominal purpose of the thruster modes, the Delta-H controller also has the added capability of performing a large angle slew maneuver. A suite of ACS components are used by the thruster based control modes, for both initialization and control. For initialization purposes, a star tracker or the Kalman Filter solution is used for providing attitude knowledge and upon entrance into the thruster based control modes attitude knowledge is provided via rate propagation using a inertial reference unit (IRU). Rate information for the controller is also supplied by the IRU. Three-axis control of the spacecraft in the thruster modes is provided by eight 5-lbf class attitude control thrusters configured in two sets of four thrusters for redundancy purposes. Four additional 20-lbf class thrusters configured in two sets of two thrusters are used for Lunar Orbit Insertion maneuvers. The propulsion system is one the few systems on-board the LRO spacecraft that has built in redundancy. The Delta-H controller consists of a Proportional-Derivative (PD) controller with a structural filter on the thrusters and a Proportional controller on the reaction wheels. The PD control that employs the thrusters is used for attitude and rate control. The Proportional controller on the reaction wheels is used for commanding the wheels to a new momentum state. The ground commands used for the Delta-H controller are the system momentum vector, reaction wheel momentum, maximum expected command time, and which set of attitude control thrusters to use. The ability to command both the system momentum vector and reaction wheel momentum in the Delta-H controller provides both a capability and an additional source of operator error. Large angle slews via the Delta-H controller is achievable via this commands because these commands are used for the exit mode criteria. Setting these commands to non-consistent values prevents the mode from exiting nominally.

  9. Method of using an electric field controlled emulsion phase contactor

    DOEpatents

    Scott, T.C.

    1993-11-16

    A system is described for contacting liquid phases comprising a column for transporting a liquid phase contacting system, the column having upper and lower regions. The upper region has a nozzle for introducing a dispersed phase and means for applying thereto a vertically oriented high intensity pulsed electric field. This electric field allows improved flow rates while shattering the dispersed phase into many micro-droplets upon exiting the nozzle to form a dispersion within a continuous phase. The lower region employs means for applying to the dispersed phase a horizontally oriented high intensity pulsed electric field so that the dispersed phase undergoes continuous coalescence and redispersion while being urged from side to side as it progresses through the system, increasing greatly the mass transfer opportunity. 5 figures.

  10. Quantitative Single-Ion Irradiation by ASIPP Microbeam

    NASA Astrophysics Data System (ADS)

    Wang, Xu-Fei; Chen, Lian-Yun; Hu, Zhi-Wen; Wang, Xiao-Hua; Zhang, Jun; Li, Jun; Chen, Bin; Hu, Su-Hua; Shi, Zhong-Tao; Wu, Yu; Xu, Ming-Liang; Wu, Li-Jun; Wang, Shao-Hu; Yu, Zeng-Liang

    2004-05-01

    A single-ion microbeam facility has been constructed by the microbeam research group in ASIPP (Institute of Plasma Physics, Chinese Academy of Science). The system was designed to deliver defined numbers of hydrogen ions produced by a van de Graaff accelerator, covering an energy range from 200 keV to 3 MeV, into living cells (5 mum-20 mum diameter) growing in culture on thin plastic films. The beam is collimated by a 1- mum inner diameter HPLC (high performance liquid chromatography) capillary, which forms the micron-dimensional beam-line exit. A microbeam collimator, a scintillation ion counting system and a fast beam shutter, which constitute a precise dosage measuring and controlling system, jointly perform quantitative single-ion irradiation. With this facility, we can presently acquire ion-hitting efficiency close to 95%.

  11. Comparison of measurement data at the impeller exit of a centrifugal compressor measured with both pneumatic and fast-response probes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roduner, C.; Koeppel, P.; Kupferschmied, P.

    1999-07-01

    The main goal of these investigations was the refined measurement of unsteady high speed flow in a centrifugal compressor using the advanced FRAP{reg_sign} fast-response aerodynamic probe system. The present contribution focuses on the impeller exit region and shows critical comparisons between fast-response (time-resolving) and conventional pneumatic probe measurement results. Three probes of identical geometry (one fast and two pneumatic) were used to perform wall-to-wall traverses close to impeller exit. The data shown refer to a single running condition near the best point of the stage. The mass flow obtained from different probe measurements and from the standard orifice measurement weremore » compared. Stage work obtained from temperature rise measured with a FRAP{reg_sign} probe and from impeller outlet velocity vectors fields by using Euler`s turbine equation are presented. The comparison in terms of velocity magnitude and angle distribution is quite satisfactory, indicating the superior DC measurement capabilities of the fast-response probe system.« less

  12. Optical diagnostics integrated with laser spark delivery system

    DOEpatents

    Yalin, Azer [Fort Collins, CO; Willson, Bryan [Fort Collins, CO; Defoort, Morgan [Fort Collins, CO; Joshi, Sachin [Fort Collins, CO; Reynolds, Adam [Fort Collins, CO

    2008-09-02

    A spark delivery system for generating a spark using a laser beam is provided, and includes a laser light source and a laser delivery assembly. The laser delivery assembly includes a hollow fiber and a launch assembly comprising launch focusing optics to input the laser beam in the hollow fiber. The laser delivery assembly further includes exit focusing optics that demagnify an exit beam of laser light from the hollow fiber, thereby increasing the intensity of the laser beam and creating a spark. Other embodiments use a fiber laser to generate a spark. Embodiments of the present invention may be used to create a spark in an engine. Yet other embodiments include collecting light from the spark or a flame resulting from the spark and conveying the light for diagnostics. Methods of using the spark delivery systems and diagnostic systems are provided.

  13. Fiber laser coupled optical spark delivery system

    DOEpatents

    Yalin, Azer [Fort Collins, CO; Willson, Bryan [Fort Collins, CO; Defoort, Morgan [Fort Collins, CO; Joshi, Sachin [Fort Collins, CO; Reynolds, Adam [Fort Collins, CO

    2008-03-04

    A spark delivery system for generating a spark using a laser beam is provided, and includes a laser light source and a laser delivery assembly. The laser delivery assembly includes a hollow fiber and a launch assembly comprising launch focusing optics to input the laser beam in the hollow fiber. The laser delivery assembly further includes exit focusing optics that demagnify an exit beam of laser light from the hollow fiber, thereby increasing the intensity of the laser beam and creating a spark. Other embodiments use a fiber laser to generate a spark. Embodiments of the present invention may be used to create a spark in an engine. Yet other embodiments include collecting light from the spark or a flame resulting from the spark and conveying the light for diagnostics. Methods of using the spark delivery systems and diagnostic systems are provided.

  14. Missiles in the cardiovascular system.

    PubMed

    Symbas, P N; Symbas, P J

    1997-05-01

    A missile in the cardiovascular system is a rare complication of a projectile wound. A missile in the heart should be suspected in the patient with a projectile wound of the thorax and in whom, on chest radiography, a missile is seen in the cardiac silhouette. A missile should be suspected in the patient with a projectile wound elsewhere with similar radiographic findings, no exit wound, and no missile in the area of injury. A missile in the arterial system should be suspected when no exit wound and no projectile are seen in the traumatized area. In such a case, radiography of the entire body should be done. The diagnosis of a suspected missile in the cardiovascular system is confirmed by echocardiography or angiography. Treatment should be individualized according to the clinical manifestations of the patient and the site of the missile.

  15. 78 FR 21188 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-09

    ... wholly outside of its control. Typically, maintenance responsibilities for in- pavement inductive-loop... exit gates not impacted by State design parameters that require such gates to remain in the vertical...

  16. Multi-pass amplifier architecture for high power laser systems

    DOEpatents

    Manes, Kenneth R; Spaeth, Mary L; Erlandson, Alvin C

    2014-04-01

    A main amplifier system includes a first reflector operable to receive input light through a first aperture and direct the input light along an optical path. The input light is characterized by a first polarization. The main amplifier system also includes a first polarizer operable to reflect light characterized by the first polarization state. The main amplifier system further includes a first and second set of amplifier modules. Each of the first and second set of amplifier modules includes an entrance window, a quarter wave plate, a plurality of amplifier slablets arrayed substantially parallel to each other, and an exit window. The main amplifier system additionally includes a set of mirrors operable to reflect light exiting the first set of amplifier modules to enter the second set of amplifier modules and a second polarizer operable to reflect light characterized by a second polarization state.

  17. A Randomized Controlled Trial of Acupuncture in Stable Ischemic Heart Disease Patients

    PubMed Central

    Mehta, Puja K.; Polk, Donna M.; Zhang, Xiao; Li, Ning; Painovich, Jeannette; Kothawade, Kamlesh; Kirschner, Joan; Qiao, Yi; Ma, Xiuling; Chen, Yii-Der Ida; Brantman, Anna; Shufelt, Chrisandra; Minissian, Margo; Bairey Merz, C. Noel

    2014-01-01

    Background Heart rate variability (HRV) is reduced in stable ischemic heart disease (SIHD) patients and is associated with sudden cardiac death (SCD). We evaluated the impact of traditional acupuncture (TA) on cardiac autonomic function measured by HRV in SIHD patients. Methods We conducted a randomized controlled study of TA, sham acupuncture (SA), and waiting control (WC) in 151 SIHD subjects. TA group received needle insertion at acupuncture sites, SA group received a sham at non-acupuncture sites, while WC received nothing. TA and SA received 3 treatments/week for 12 wks. 24-hour, mental arithmetic stress, and cold pressor (COP) HRV was collected at entry and exit, along with BP, lipids, insulin resistance, hs-CRP, salivary cortisol, peripheral endothelial function by tonometry(PAT), and psychosocial variables. Results Mean age was 63±10; 50% had prior myocardial infarction. Comparison of WC and SA groups demonstrated differences consistent with the unblinded WC status; therefore by design, the control groups were not merged. Exit mental stress HRV was higher in TA vs. SA for markers of parasympathetic tone (p≤0.025), including a 17% higher vagal activity (p=0.008). There were no differences in exit 24-hour or COP HRV, BP, lipids, insulin resistance, hs-CRP, salivary cortisol, PAT, or psychosocial variables. Conclusions TA results in intermediate effects on autonomic function in SIHD patients. TA effect on HRV may be clinically relevant and should be explored further. These data document feasibility and provide sample size estimation for a clinical trial of TA in SIHD patients for prevention of SCD. PMID:25103909

  18. Fluorescence Imaging of Rotational and Vibrational Temperature in a Shock Tunnel Nozzle Flow

    NASA Technical Reports Server (NTRS)

    Palma, Philip C.; Danehy, Paul M.; Houwing, A. F. P.

    2003-01-01

    Two-dimensional rotational and vibrational temperature measurements were made at the nozzle exit of a free-piston shock tunnel using planar laser-induced fluorescence. The Mach 7 flow consisted predominantly of nitrogen with a trace quantity of nitric oxide. Nitric oxide was employed as the probe species and was excited at 225 nm. Nonuniformities in the distribution of nitric oxide in the test gas were observed and were concluded to be due to contamination of the test gas by driver gas or cold test gas.The nozzle-exit rotational temperature was measured and is in reasonable agreement with computational modeling. Nonlinearities in the detection system were responsible for systematic errors in the measurements. The vibrational temperature was measured to be constant with distance from the nozzle exit, indicating it had frozen during the nozzle expansion.

  19. Conceptual study and key technology development for Mars Aeroflyby sample collection

    NASA Astrophysics Data System (ADS)

    Fujita, K.; Ozawa, T.; Okudaira, K.; Mikouchi, T.; Suzuki, T.; Takayanagi, H.; Tsuda, Y.; Ogawa, N.; Tachibana, S.; Satoh, T.

    2014-01-01

    Conceptual study of Mars Aeroflyby Sample Collection (MASC) is conducted as a part of the next Mars exploration mission currently entertained in Japan Aerospace Exploration Agency. In the mission scenario, an atmospheric entry vehicle is flown into the Martian atmosphere, collects the Martian dust particles as well as atmospheric gases during the guided hypersonic flight, exits the Martian atmosphere, and is inserted into a parking orbit from which a return system departs for the earth to deliver the dust and gas samples. In order to accomplish a controlled flight and a successful orbit insertion, aeroassist orbit transfer technologies are introduced into the guidance and control system. System analysis is conducted to assess the feasibility and to make a conceptual design, finding that the MASC system is feasible at the minimum system mass of 600 kg approximately. The aerogel, which is one of the candidates for the dust sample collector, is assessed by arcjet heating tests to examine its behavior when exposed to high-temperature gases, as well as by particle impingement tests to evaluate its dust capturing capability.

  20. Effects of nozzle exit geometry and pressure ratio on plume shape for nozzles exhausting into quiescent air

    NASA Technical Reports Server (NTRS)

    Scallion, William I.

    1991-01-01

    The effects of varying the exit geometry on the plume shapes of supersonic nozzles exhausting into quiescent air at several exit-to-ambient pressure ratios are given. Four nozzles having circular throat sections and circular, elliptical and oval exit cross sections were tested and the exit plume shapes are compared at the same exit-to-ambient pressure ratios. The resulting mass flows were calculated and are also presented.

  1. Prediction of active control of subsonic centrifugal compressor rotating stall

    NASA Technical Reports Server (NTRS)

    Lawless, Patrick B.; Fleeter, Sanford

    1993-01-01

    A mathematical model is developed to predict the suppression of rotating stall in a centrifugal compressor with a vaned diffuser. This model is based on the employment of a control vortical waveform generated upstream of the impeller inlet to damp weak potential disturbances that are the early stages of rotating stall. The control system is analyzed by matching the perturbation pressure in the compressor inlet and exit flow fields with a model for the unsteady behavior of the compressor. The model was effective at predicting the stalling behavior of the Purdue Low Speed Centrifugal Compressor for two distinctly different stall patterns. Predictions made for the effect of a controlled inlet vorticity wave on the stability of the compressor show that for minimum control wave magnitudes, on the order of the total inlet disturbance magnitude, significant damping of the instability can be achieved. For control waves of sufficient amplitude, the control phase angle appears to be the most important factor in maintaining a stable condition in the compressor.

  2. 14 CFR 27.805 - Flight crew emergency exits.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flight crew emergency exits. 27.805 Section... § 27.805 Flight crew emergency exits. (a) For rotorcraft with passenger emergency exits that are not convenient to the flight crew, there must be flight crew emergency exits, on both sides of the rotorcraft or...

  3. 14 CFR 29.805 - Flight crew emergency exits.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flight crew emergency exits. 29.805 Section... Accommodations § 29.805 Flight crew emergency exits. (a) For rotorcraft with passenger emergency exits that are not convenient to the flight crew, there must be flight crew emergency exits, on both sides of the...

  4. 14 CFR 29.805 - Flight crew emergency exits.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flight crew emergency exits. 29.805 Section... Accommodations § 29.805 Flight crew emergency exits. (a) For rotorcraft with passenger emergency exits that are not convenient to the flight crew, there must be flight crew emergency exits, on both sides of the...

  5. 14 CFR 27.805 - Flight crew emergency exits.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flight crew emergency exits. 27.805 Section... § 27.805 Flight crew emergency exits. (a) For rotorcraft with passenger emergency exits that are not convenient to the flight crew, there must be flight crew emergency exits, on both sides of the rotorcraft or...

  6. Integrated Theoretical, Computational, and Experimental Studies for Transition Estimation and Control

    DTIC Science & Technology

    2014-06-03

    nozzle exit) was developed to aid in porting the VENOM diagnostic to high-enthalpy impulse tunnels. Measurements were also made in the supersonic high...Colonius T, Fedorov AV. 2009. Alternate designs of ultrasonic absorptive coatings for hypersonic boundary layer control. AIAA Pap. No. 2009-4217 51. Craig

  7. 42. Upper level, electronic racks, left to rightguidance and control ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. Upper level, electronic racks, left to right--guidance and control coupler rack, programmer group, status command message processing group, UHF radio - Ellsworth Air Force Base, Delta Flight, Launch Facility, On County Road T512, south of Exit 116 off I-90, Interior, Jackson County, SD

  8. 40 CFR 63.9631 - What are my monitoring requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... inspections, vibration detectors, or equivalent means. (b) Except as provided in paragraph (c) of this section... average opacity of emissions exiting each control device stack according to the requirements in § 63.9633... pollution control device other than a baghouse, wet scrubber, dry electrostatic precipitator, or wet...

  9. 40 CFR 63.9631 - What are my monitoring requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... inspections, vibration detectors, or equivalent means. (b) Except as provided in paragraph (c) of this section... average opacity of emissions exiting each control device stack according to the requirements in § 63.9633... pollution control device other than a baghouse, wet scrubber, dry electrostatic precipitator, or wet...

  10. 40 CFR 63.9631 - What are my monitoring requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... inspections, vibration detectors, or equivalent means. (b) Except as provided in paragraph (c) of this section... average opacity of emissions exiting each control device stack according to the requirements in § 63.9633... pollution control device other than a baghouse, wet scrubber, dry electrostatic precipitator, or wet...

  11. Waveguide detection of right-angle-scattered light in flow cytometry

    DOEpatents

    Mariella, Jr., Raymond P.

    2000-01-01

    A transparent flow cell is used as an index-guided optical waveguide. A detector for the flow cell but not the liquid stream detects the Right-Angle-Scattered (RAS) Light exiting from one end of the flow cell. The detector(s) could view the trapped RAS light from the flow cell either directly or through intermediate optical light guides. If the light exits one end of the flow cell, then the other end of the flow cell can be given a high-reflectivity coating to approximately double the amount of light collected. This system is more robust in its alignment than the traditional flow cytometry systems which use imaging optics, such as microscope objectives.

  12. A randomized controlled trial comparing mupirocin versus Polysporin Triple for the prevention of catheter-related infections in peritoneal dialysis patients (the MP3 study).

    PubMed

    Jassal, Sarbjit V; Lok, Charmaine E

    2008-01-01

    Peritonitis remains the most serious complication of peritoneal dialysis (PD). Gram-positive organisms are among the most common causes of PD peritonitis; however, recent trends show increasing rates of gram-negative and fungal infections. Strategies to prevent peritonitis include the use of prophylactic topical mupirocin at the site where the PD catheter exits from the abdominal wall; however, mupirocin does not afford protection against gram-negative or fungal infections. The aim of this study is to determine if the incidence of catheter-related infections (exit-site infection, tunnel infection, or peritonitis) is significantly reduced by the routine application of Polysporin Triple antibiotic ointment (Pfizer Canada, Markham, Ontario, Canada) in comparison to mupirocin ointment. The Mupirocin Versus Polysporin Triple Study (MP3) is a multicenter, randomized, double-blinded controlled study comparing Polysporin Triple (P3) against the current standard of care. The aim of the study is to recruit 200 patients being treated with or starting on PD and randomize them to receive either mupirocin or P3 at the catheter exit site. Patients will be followed for 18 months or until death or transfer from PD to an alternate treatment modality. The primary outcome will be the time to first catheter-related infection. Catheter-related infections will be strictly defined using current guidelines and categorized into exit-site infections, infective peritonitis, or tunnel infections. The primary analysis will be an intention-to-treat analysis. The results of this study will help determine if the use of P3 is superior to mupirocin ointment in the prevention of catheter-related infections and will help guide evidence-based best practices.

  13. A randomized controlled trial comparing mupirocin and polysporin triple ointments in peritoneal dialysis patients: the MP3 Study.

    PubMed

    McQuillan, Rory F; Chiu, Ernest; Nessim, Sharon; Lok, Charmaine E; Roscoe, Janet M; Tam, Paul; Jassal, Sarbjit Vanita

    2012-02-01

    Infectious complications remain a significant cause of peritoneal dialysis (PD) technique failure. Topical ointments seem to reduce peritonitis; however, concerns over resistance have led to a quest for alternative agents. This study examined the effectiveness of applying topical Polysporin Triple ointment (P(3)) against mupirocin in a multi-centered, double-blind, randomized controlled trial. PD patients routinely applied either P(3) or mupirocin ointment to their exit site. Patients were followed for 18 months or until death or catheter removal. The primary study outcome was a composite endpoint of exit-site infection (ESI), tunnel infection, or peritonitis. Seventy-five of 201 randomized patients experienced a primary outcome event (51 peritonitis episodes, 24 ESIs). No difference was seen in the time to first event for P(3) (13.2 months; 95% confidence interval, 11.9-14.5) and mupirocin (14.0 months; 95% confidence interval, 12.7-15.4) (P=0.41). Twice as many patients reported redness at the exit site in the P(3) group (14 versus 6, P=0.10). Over the complete study period, a higher rate per year of fungal ESIs was seen in patients using P(3) (0.07 versus 0.01; P=0.02) with a corresponding increase in fungal peritonitis (0.04 versus 0.00, respectively; P<0.05). This study shows that P(3) is not superior to mupirocin in the prophylaxis of PD-related infections. Colonization of the exit site with fungal organisms is of concern and warrants further study. As such, the use of P(3) over mupirocin is not advocated in the prophylaxis of PD-related infections.

  14. Working conditions as predictors of retirement intentions and exit from paid employment: a 10-year follow-up of the English Longitudinal Study of Ageing.

    PubMed

    Carr, Ewan; Hagger-Johnson, Gareth; Head, Jenny; Shelton, Nicola; Stafford, Mai; Stansfeld, Stephen; Zaninotto, Paola

    Population ageing in Western countries has made delayed retirement and extended working life a policy priority in recent years. Retirement timing has been linked to individual factors such as health and wealth, but less is known about the role of the psychosocial work environment. This paper drew upon longitudinal data on 3462 workers aged 50-69 from five waves of the English Longitudinal Study of Ageing (ELSA). Regression models were used to assess the association of working conditions with preferred timing of retirement and actual work exit. Adjusting for a range of covariates, job demands (aspects of the job requiring sustained physical or psychological effort) were associated with preferences for earlier retirement (by 0.18 years; 95 % C.I. 0.06, 0.31). Decision authority was associated with preferences for later retirement (by 0.38 years; 95 % C.I. 0.23, 0.53) and reduced odds of work exit (OR = 0.93; 95 % C.I. 0.88, 0.97). Low recognition at work was associated with increased odds of work exit (OR = 1.23; 95 % C.I. 1.10, 1.43). There was little evidence of any interactive relationship between demands and resources. Efforts to extend working life should address issues relating to the immediate psychosocial work environment. Providing older workers with increased sense of control, and ensuring contributions are adequately recognised, may delay retirement intentions and the timing of labour market exit.

  15. Behavioral Traits are Affected by Selective Breeding for Increased Wheel-Running Behavior in Mice

    PubMed Central

    Jónás, I.; Schubert, K. A.; Reijne, A. C.; Scholte, J.; Garland, T.; Gerkema, M. P.; Scheurink, A. J. W.; Nyakas, C.

    2010-01-01

    Voluntary physical activity may be related to personality traits. Here, we investigated these relations in two mouse lines selectively bred for high voluntary wheel-running behavior and in one non-selected control line. Selection lines were more explorative and “information gathering” in the open-field test, either with increased upright positions or horizontal locomotion toward the middle ring. Furthermore, one of the selection lines had an increased risk-taking behavior relative to the control line in approaching a novel object placed in the center of the open field. However, anxiety behavior was increased in selection lines during the plus-maze test. Maze learning was not statistically different among lines, but routine behavior was increased in both selection lines when the maze exit after 2 days of testing was displaced. Specifically, in the displaced maze, selected mice traveled more frequently to the old, habituated exit, bypassing the new exit attached to their home cage. Although the generality of the results would need to be confirmed in future studies including all eight lines in the selection experiment, the increased routine and exploratory behavior (at least in the lines used in the present study) may be adaptive to sustain high activity levels. PMID:20369280

  16. Do spouses coordinate their work exits? A combined survey and register analysis from Norway.

    PubMed

    Syse, Astri; Solem, Per Erik; Ugreninov, Elisabeth; Mykletun, Reidar; Furunes, Trude

    2014-09-01

    Research on spouses' joint work exits is scarce, although household factors such as spouses' work status, marital quality, and caregiving burdens are likely to affect seniors' work engagement. We therefore examine whether the work exit probability of one spouse affects that of the other. Discrete-time hazard regression analyses of survey data linked to later registry information including all gainfully employed married respondents aged 50-74 with a working spouse (N = 1,764) were used to assess subsequent work exits. A spouse's work exit is a strong predictor of a respondent's work exit (hazard ratio 3.1, 95% confidence interval [2.5, 4.0]). Educational attainment, poor marital quality, and spouses' health and care needs do not predict work exits. Surprisingly, no gender differences are observed. Research on larger survey samples to distinguish different work exit routes and reasons for spouses' joint work exits appears warranted. To account for cultural and welfare state characteristics, cross-national studies ought to be undertaken. © The Author(s) 2013.

  17. 10. Helicopter pad, fire extinguisher at center, looking southwest ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Helicopter pad, fire extinguisher at center, looking southwest - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  18. 63. Refrigerator, microwave oven, storage cabinet open, north side ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    63. Refrigerator, microwave oven, storage cabinet open, north side - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  19. Numerical Evaluation of an Ejector-Enhanced Resonant Pulse Combustor with a Poppet Inlet Valve and a Converging Exhaust Nozzle

    NASA Technical Reports Server (NTRS)

    Yungster, Shaye; Paxson, Daniel E.; Perkins, Hugh D.

    2016-01-01

    A computational investigation of a pressure-gain combustor system for gas turbine applications is presented. The system consists of a valved pulse combustor and an ejector, housed within a shroud. The study focuses on two enhancements to previous models, related to the valve and ejector components. First, a new poppet inlet valve system is investigated, replacing the previously used reed valve configuration. Secondly, a new computational approach to approximating the effects of choked turbine inlet guide vanes present immediately downstream of the Ejector-Enhanced Resonant Pulse Combustor (EERPC) is investigated. Instead of specifying a back pressure at the EERPC exit boundary (as was done in previous studies) the new model adds a converging-diverging (CD) nozzle at the exit of the EERPC. The throat area of the CD nozzle can be adjusted to obtain the desired back pressure level and total mass flow rate. The results presented indicate that the new poppet valve configuration performs nearly as well as the original reed valve system, and that the addition of the CD nozzle is an effective method to approximate the exit boundary effects of a turbine present downstream of the EERPC. Furthermore, it is shown that the more acoustically reflective boundary imposed by a nozzle as compared to a constant pressure surface does not significantly affect operation or performance.

  20. Development of a Pulsed Combustion Actuator For High-Speed Flow Control

    NASA Technical Reports Server (NTRS)

    Cutler, Andrew D.; Beck, B. Terry; Wilkes, Jennifer A.; Drummond, J. Philip; Alderfer, David W.; Danehy, Paul M.

    2005-01-01

    This paper describes the flow within a prototype actuator, energized by pulsed combustion or detonations, that provides a pulsed jet suitable for flow control in high-speed applications. A high-speed valve, capable of delivering a pulsed stream of reactants a mixture of H2 and air at rates of up to 1500 pulses per second, has been constructed. The reactants burn in a resonant chamber, and the products exit the device as a pulsed jet. High frequency pressure transducers have been used to monitor the pressure fluctuations in the device at various reactant injection frequencies, including both resonant and off-resonant conditions. The combustion chamber has been constructed with windows, and the flow inside it has been visualized using Planar Laser-Induced Fluorescence (PLIF). The pulsed jet at the exit of the device has been observed using schlieren.

  1. Evaluation of biological hydrogen sulfide oxidation coupled with two-stage upflow filtration for groundwater treatment.

    PubMed

    Levine, Audrey D; Raymer, Blake J; Jahn, Johna

    2004-01-01

    Hydrogen sulfide in groundwater can be oxidized by aerobic bacteria to form elemental sulfur and biomass. While this treatment approach is effective for conversion of hydrogen sulfide, it is important to have adequate control of the biomass exiting the biological treatment system to prevent release of elemental sulfur into the distribution system. Pilot scale tests were conducted on a Florida groundwater to evaluate the use of two-stage upflow filtration downstream of biological sulfur oxidation. The combined biological and filtration process was capable of excellent removal of hydrogen sulfide and associated turbidity. Additional benefits of this treatment approach include elimination of odor generation, reduction of chlorine demand, and improved stability of the finished water.

  2. Prior Individual Training and Self-Organized Queuing during Group Emergency Escape of Mice from Water Pool

    PubMed Central

    Saloma, Caesar; Perez, Gay Jane; Gavile, Catherine Ann; Ick-Joson, Jacqueline Judith; Palmes-Saloma, Cynthia

    2015-01-01

    We study the impact of prior individual training during group emergency evacuation using mice that escape from an enclosed water pool to a dry platform via any of two possible exits. Experimenting with mice avoids serious ethical and legal issues that arise when dealing with unwitting human participants while minimizing concerns regarding the reliability of results obtained from simulated experiments using ‘actors’. First, mice were trained separately and their individual escape times measured over several trials. Mice learned quickly to swim towards an exit–they achieved their fastest escape times within the first four trials. The trained mice were then placed together in the pool and allowed to escape. No two mice were permitted in the pool beforehand and only one could pass through an exit opening at any given time. At first trial, groups of trained mice escaped seven and five times faster than their corresponding control groups of untrained mice at pool occupancy rate ρ of 11.9% and 4%, respectively. Faster evacuation happened because trained mice: (a) had better recognition of the available pool space and took shorter escape routes to an exit, (b) were less likely to form arches that blocked an exit opening, and (c) utilized the two exits efficiently without preference. Trained groups achieved continuous egress without an apparent leader-coordinator (self-organized queuing)—a collective behavior not experienced during individual training. Queuing was unobserved in untrained groups where mice were prone to wall seeking, aimless swimming and/or blind copying that produced circuitous escape routes, biased exit use and clogging. The experiments also reveal that faster and less costly group training at ρ = 4%, yielded an average individual escape time that is comparable with individualized training. However, group training in a more crowded pool (ρ = 11.9%) produced a longer average individual escape time. PMID:25693170

  3. Shape memory alloy actuation for a variable area fan nozzle

    NASA Astrophysics Data System (ADS)

    Rey, Nancy; Tillman, Gregory; Miller, Robin M.; Wynosky, Thomas; Larkin, Michael J.; Flamm, Jeffrey D.; Bangert, Linda S.

    2001-06-01

    The ability to control fan nozzle exit area is an enabling technology for next generation high-bypass-ratio turbofan engines. Performance benefits for such designs are estimated at up to 9% in thrust specific fuel consumption (TSFC) relative to current fixed-geometry engines. Conventionally actuated variable area fan nozzle (VAN) concepts tend to be heavy and complicated, with significant aircraft integration, reliability and packaging issues. The goal of this effort was to eliminate these undesirable features and formulate a design that meets or exceeds leakage, durability, reliability, maintenance and manufacturing cost goals. A Shape Memory Alloy (SMA) bundled cable actuator acting to move an array of flaps around the fan nozzle annulus is a concept that meets these requirements. The SMA bundled cable actuator developed by the United Technologies Corporation (Patents Pending) provides significant work output (greater than 2200 in-lb per flap, through the range of motion) in a compact package and minimizes system complexity. Results of a detailed design study indicate substantial engine performance, weight, and range benefits. The SMA- based actuation system is roughly two times lighter than a conventional mechanical system, with significant aircraft direct operating cost savings (2-3%) and range improvements (5-6%) relative to a fixed-geometry nozzle geared turbofan. A full-scale sector model of this VAN system was built and then tested at the Jet Exit Test Facility at NASA Langley to demonstrate the system's ability to achieve 20% area variation of the nozzle under full scale aerodynamic loads. The actuator exceeded requirements, achieving repeated actuation against full-scale loads representative of typical cruise as well as greater than worst-case (ultimate) aerodynamic conditions. Based on these encouraging results, work is continuing with the goal of a flight test on a C-17 transport aircraft.

  4. Long noncoding RNA PANDA and scaffold-attachment-factor SAFA control senescence entry and exit.

    PubMed

    Puvvula, Pavan Kumar; Desetty, Rohini Devi; Pineau, Pascal; Marchio, Agnés; Moon, Anne; Dejean, Anne; Bischof, Oliver

    2014-11-19

    Cellular senescence is a stable cell cycle arrest that limits the proliferation of pre-cancerous cells. Here we demonstrate that scaffold-attachment-factor A (SAFA) and the long noncoding RNA PANDA differentially interact with polycomb repressive complexes (PRC1 and PRC2) and the transcription factor NF-YA to either promote or suppress senescence. In proliferating cells, SAFA and PANDA recruit PRC complexes to repress the transcription of senescence-promoting genes. Conversely, the loss of SAFA-PANDA-PRC interactions allows expression of the senescence programme. Accordingly, we find that depleting either SAFA or PANDA in proliferating cells induces senescence. However, in senescent cells where PANDA sequesters transcription factor NF-YA and limits the expression of NF-YA-E2F-coregulated proliferation-promoting genes, PANDA depletion leads to an exit from senescence. Together, our results demonstrate that PANDA confines cells to their existing proliferative state and that modulating its level of expression can cause entry or exit from senescence.

  5. Accuracy of a real-time surgical navigation system for the placement of quad zygomatic implants in the severe atrophic maxilla: A pilot clinical study.

    PubMed

    Hung, Kuo-Feng; Wang, Feng; Wang, Hao-Wei; Zhou, Wen-Jie; Huang, Wei; Wu, Yi-Qun

    2017-06-01

    A real-time surgical navigation system potentially increases the accuracy when used for quad-zygomatic implant placement. To evaluate the accuracy of a real-time surgical navigation system when used for quad zygomatic implant placement. Patients with severely atrophic maxillae were prospectively recruited. Four trajectories for implants were planned, and zygomatic implants were placed using a real-time surgical navigation system. The planned-placed distance deviations at entry (entry deviation)points, exit (exit deviation) points, and angle deviation of axes (angle deviation) were measured on fused operation images. The differences of all the deviations between different groups, classified based on the lengths and locations of implants, were analysed. A P value of < 0.05 indicated statistical significance. Forty zygomatic implants were placed as planned in 10 patients. The entry deviation, exit deviation and angle deviation were 1.35 ± 0.75 mm, 2.15 mm ± 0.95 mm, and 2.05 ± 1.02 degrees, respectively. The differences of all deviations were not significant, irrespective of the lengths (P = .259, .158, and .914, respectively) or locations of the placed implants (P = .698, .072, and .602, respectively). A real-time surgical navigation system used for the placement of quad zygomatic implants demonstrated a high level of accuracy with only minimal planned-placed deviations, irrespective of the lengths or locations of the implants. © 2017 Wiley Periodicals, Inc.

  6. Exit-Site Infection of Peritoneal Catheter is Reduced by the Use of Polyhexanide. Results of a Prospective Randomized Trial

    PubMed Central

    Núñez-Moral, M.; Sánchez-Álvarez, E.; González-Díaz, I.; Peláez-Requejo, B.; Fernández-Viña, A.; Quintana-Fernández, A.; Rodríguez-Suárez, C.

    2014-01-01

    ♦ Background: One of the most common and severe complications affecting peritoneal dialysis (PD) patients is exit-site infection of the peritoneal catheter; it is therefore of vital importance to prevent it. This complication has a negative impact on the success of the technique. In spite of this, there are no clear guidelines concerning how to take care of the exit site. The objective of this study was to assess the efficacy of polyhexanide in preventing exit-site infection over a 12-month period. ♦ Methods: We designed a single-center, prospective, open-labeled, randomized controlled clinical trial with parallel groups. Requirements for participation in the study included implantation of the peritoneal catheter at least six weeks before entering the study and no infectious complications requiring either hospital admission or antibiotic treatment for at least three months before entering into the study. Patients were randomized to be daily cured as follows: Group A: traditional care with saline serum and povidone-iodine; and Group B: polyhexanide solution. Exit sites were evaluated at baseline and every four to six weeks or if any event occurred, according to the Twardowski criteria. ♦ Results: Of the 60 included patients, 46 completed the 12-month follow-up period. Six underwent transplantation, five died and three were transferred to hemodialysis (HD). The treatment was well tolerated, with no side effects nor abandonments due to such effects. Throughout the study period, six patients (20%) undergoing traditional care and only two (6,7%) receiving polyhexanide developed an exit-site infection (p = 0.032). There were a total number of 12 infections; nine occurred in patients following the traditional approach and only three in patients treated with polyhexanide (p = 0.037). The germs responsible for the infections were: S. aureus (six cases), Corynebacterium jeikeium (two cases) and P. aeruginosa (one case) in the saline serum and povidone-iodine group and P. aeruginosa (three cases) in the polyhexanide group. The mean rate of exit-site infection was 1 episode/36.6 patient-months for the traditional care group and 1 episode/102.7 patient-months for the polyhexanide group (p = 0.017). Patients following the traditional treatment required fewer days to get infected than those using polyhexanide (p = 0.033; log rank: 4.2). ♦ Conclusions: These results show that using polyhexanide is efficient for the prevention of exit-site infections. Patients treated with this product suffer from fewer infections and need more time to become infected. Polyhexanide application is painless, no allergies have been described and it is well tolerated by patients. We therefore propose that it may be used routinely from now on for the care of healthy exit site. PMID:24497599

  7. On the start up of supersonic underexpanded jets

    NASA Astrophysics Data System (ADS)

    Lacerda, Nehemias Lima

    An impulsively started jet can be formed by a gas confined in a high pressure reservoir that escapes suddenly through an exit orifice, into a controlled atmosphere. Supersonic gas jets of this type are unsteady and differ from the steady jet that develops later by the presence of a bow shock, a jet head and a nonstationary Mach disk. The effects of the pressure ratio between the high pressure gas inside the reservoir and the lower pressure atmospheric gas, as well as the gas combination used, are studied experimentally. The gases used for the jet and the atmosphere were selected from helium, nitrogen and sulfur hexafluoride. The data acquisition consisted of: high resolution flash photography to obtain detail from the pictures; high-speed movie pictures to obtain the time development of selected features; and fast-response pressure transducers located at the reservoir end plate, the tank end plate and the jet exit. The initial development of the jet is highly time dependent. During this phase, the shape that the jet assumes varies with pressure ratio and with the choice of gas. In particular an extremely light gas exhausting into a heavy atmosphere, exhibits an uncommon shape. It develops as a bubble wrapped by the bow shock, that increases its volume with flow time and pressure ratio. As the pressure ratio increases, it becomes more tightly wrapped by the bow shock. At later times the jet assumes conventional linear growth. After the jet starts, a Mach disk is observed close to the jet exit which moves downstream as the exit pressure builds up. The monotonic increase in exit pressure is caused by the slow breaking of the diaphragm. The position of the Mach disk is furthest from the jet exit when the exit pressure is a maximum. After that it oscillates around the location predicted by the steady theory of Ashkenas and Sherman (1966) at a frequency close to one of the resonant frequencies of the reservoir. The features observed for the inner structure of the jet were verified to agree with those obtained for impulsive flow generated by a muzzle blast. The frontal part of the jet forms the jet head, whose shape changes with the flow conditions. The initial evolution of the jet head is linear but after propagating a distance of around ten exit diameters, it reaches asymptotic behavior with an evolution that is approximately proportional to square root of time. The head creates a bow shock ahead of it that propagates downstream and increases the pressure of the atmospheric gas. This bow shock was found to be less attenuated than in spherically symmetric explosions. The asymptotic behavior of the bow shock was reached after about eight exit diameters.

  8. The diffusion of a Ga atom on GaAs(001)β2(2 × 4): Local superbasin kinetic Monte Carlo

    NASA Astrophysics Data System (ADS)

    Lin, Yangzheng; Fichthorn, Kristen A.

    2017-10-01

    We use first-principles density-functional theory to characterize the binding sites and diffusion mechanisms for a Ga adatom on the GaAs(001)β 2(2 × 4) surface. Diffusion in this system is a complex process involving eleven unique binding sites and sixteen different hops between neighboring binding sites. Among the binding sites, we can identify four different superbasins such that the motion between binding sites within a superbasin is much faster than hops exiting the superbasin. To describe diffusion, we use a recently developed local superbasin kinetic Monte Carlo (LSKMC) method, which accelerates a conventional kinetic Monte Carlo (KMC) simulation by describing the superbasins as absorbing Markov chains. We find that LSKMC is up to 4300 times faster than KMC for the conditions probed in this study. We characterize the distribution of exit times from the superbasins and find that these are sometimes, but not always, exponential and we characterize the conditions under which the superbasin exit-time distribution should be exponential. We demonstrate that LSKMC simulations assuming an exponential superbasin exit-time distribution yield the same diffusion coefficients as conventional KMC.

  9. Performance Characteristics of Flush and Shielded Auxiliary Exits at Mach Numbers of 1.5 to 2.0

    NASA Technical Reports Server (NTRS)

    Abdalla, Kaleel L.

    1959-01-01

    The performance characteristics of several flush and shielded auxiliary exits were investigated at Mach numbers of 1.5 to 2.0, and jet pressure ratios from jet off to 10. The results indicate that the shielded configurations produced better overall performance than the corresponding flush exits over the Mach-number and pressure-ratio ranges investigated. Furthermore, the full-length shielded exit was highest in performance of all the configurations. The flat-exit nozzle block provided considerably improved performance compared with the curved-exit nozzle block.

  10. 76 FR 54260 - Dominion Nuclear Connecticut, Inc., Millstone Power Station, Unit Nos. 1, 2, and 3; Environmental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ... action would provide exemption from the work hour control requirements of 10 CFR 26.205(c) and (d) during... work hour controls on vital personnel could impede the ability to focus on plant safety and security... which the work hour control exemption applies, to exiting the condition, is limited to severe weather...

  11. Can favourable psychosocial working conditions in midlife moderate the risk of work exit for chronically ill workers? A 20-year follow-up of the Whitehall II study.

    PubMed

    Fleischmann, Maria; Carr, Ewan; Stansfeld, Stephen A; Xue, Baowen; Head, Jenny

    2018-03-01

    To investigate if favourable psychosocial working conditions can reduce the risk of work exit and specifically for workers with chronic disease. Men and women (32%) aged 35-55, working and having no chronic disease at baseline of the Whitehall II study of London-based civil servants were selected (n=9040). We observed participants' exit from work through retirement, health-related exit and unemployment, new diagnosis of chronic disease (ie, coronary heart disease, diabetes, stroke and cancer) and their psychosocial working conditions in midlife. Using cause-specific Cox models, we examined the association of chronic disease and favourable psychosocial working conditions and their interaction, with the three types of work exit. We adjusted for gender, occupational grade, educational level, remaining in civil service, spouse's employment status and mental health. Chronic disease significantly increased the risk of any type of work exit (HR 1.27) and specifically the risk of health-related exit (HR 2.42). High skill discretion in midlife reduced the risk of any type of work exit (HR 0.90), retirement (HR 0.91) and health-related exit (HR 0.68). High work social support in midlife decreased the risk of health-related exit (HR 0.79) and unemployment (HR 0.71). Favourable psychosocial working conditions in midlife did not attenuate the association between chronic disease and work exit significantly. The chronically ill have increased risks of work exit, especially through health-related exit routes. Chronic disease is an obstacle to extended working lives. Favourable working conditions directly relate to reduced risks of work exit. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Assessment of WMATA's Automatic Fare Collection Equipment Performance

    DOT National Transportation Integrated Search

    1981-01-01

    The Washington Metropolitan Area Transit Authority (WMATA) has had an Automatic Fare Collection (AFC) system in operation since June 1977. The AFC system, comprised of entry/exit gates, farecard vendors, and addfare machines, initially encountered ma...

  13. Airbag system and method for facilitating emergency egress from an aircraft

    NASA Technical Reports Server (NTRS)

    Rawdon, Blaine K. (Inventor); Hawley, Arthur V. (Inventor)

    2002-01-01

    An airbag system for elevating the fuselage of an aircraft off a landing surface a sufficient degree to allow for emergency egress of passengers and crew through ventral emergency exit doors. An airbag assembly made up of a plurality of independent airbags is disposed within the aircraft. When activated, the airbag system deploys the airbags external of the aircraft that elevate the fuselage of the aircraft a sufficient degree to allow for utilizing the ventral emergency exit doors on the fuselage to enable evacuating the passengers and crew. An activation mechanism is connected to the inflation.devices associated with each of the airbags. The activation mechanism generates an electrical signal which activates the inflation devices, which in turn fill the airbags with a compressed fluid, thus expanding the airbags and lifting the fuselage. A crew member initiates the activation of the airbag system through one or more switches.

  14. Fiber coupled optical spark delivery system

    DOEpatents

    Yalin, Azer; Willson, Bryan; Defoort, Morgan

    2008-08-12

    A spark delivery system for generating a spark using a laser beam is provided, the spark delivery system including a laser light source and a laser delivery assembly. The laser delivery assembly includes a hollow fiber and a launch assembly comprising launch focusing optics to input the laser beam in the hollow fiber. In addition, the laser delivery assembly includes exit focusing optics that demagnify an exit beam of laser light from the hollow fiber, thereby increasing the intensity of the laser beam and creating a spark. In accordance with embodiments of the present invention, the assembly may be used to create a spark in a combustion engine. In accordance with other embodiments of the present invention, a method of using the spark delivery system is provided. In addition, a method of choosing an appropriate fiber for creating a spark using a laser beam is also presented.

  15. A new bed-exiting alarm system for welfare facility residents.

    PubMed

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Caldwell, W

    2009-01-01

    A newly developed alarm system detects welfare facility residents leaving their beds, and does not respond to the care staff, who wear shoes or slippers. It employs a stainless steel tape electrode, several linear integrated circuits and a low-power 8-bit single chip microcomputer. The electrode, which is used as a bed-exiting detection sensor, is attached to the floor mat to record changes in the always-present AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the standard 100 volt, 60 Hz AC utility power wiring in the room walls and ceiling. The resident's body movements, before trying to get out of bed and after leaving the bed, are detected by the microcomputer from changes in the induced AC voltage. The microcomputer alerts the care staff station, via a power line communication system or PHS (personal handy phone System).

  16. Pin1 as a Biomarker of ER+ Breast Cancers to Predict the Response to Tamoxifen and mTOR Inhibitors

    DTIC Science & Technology

    2009-04-01

    for Pin1 in modulating S6K and Akt activity. We did, however, find a modest but reproducible defect in global protein synthesis and G0 exit. To...MEFs led to a small but reproducible defect in global protein synthesis and G0 exit. The immune system is comprised of multiple cell types that...and Franchi , L. STAT3 tyrosine phosphorylation is critical for interleukin 1 beta and interleukin-6 production in response to lipopolysaccharide and

  17. 2006 Joint Services Small Arms Systems Annual Symposium, Exhibition and Firing Demonstration

    DTIC Science & Technology

    2006-05-18

    FE FE FE /F H FE/FH FE FH EXIT EX IT EX IT EX IT EXIT FH - FIRE HOSE FE - FIRE EXTINGUISHER N S W E LOUNGE 20 20 LOUNGE 20 20 31’ AAI Corporation 302...Sniper Rifle Congressional Program, Mr. Neil E . Lee, US Army ARDEC • Plasma Transfer Arc Fabrication of Enhanced Performance Barrels, Mr. Kris C...Years of Small Arms (1326 – 1626)”, Dr. Stephen C. Small, JSSAP/ARDEC Session IV: International Programs • Small Arms in NATO Transformation, Mr. Vernon E

  18. Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

    NASA Technical Reports Server (NTRS)

    Lagen, Nicholas T.; Seiner, John M.

    1990-01-01

    The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

  19. Alerting device and method for reminding a person of a risk

    DOEpatents

    Runyon, Larry [Richland, WA; Gunter, Wayne M [West Richland, WA; Pratt, Richard M [Richland, WA

    2001-11-27

    An alerting device and method to remind personnel of a risk is disclosed. The device has at least two sensors, a logic controller, a power source, and an annunciator that delivers a visual message, with or without an audible alarm, about a risk to a person when the sensors detect the person exiting a predetermined space. In particular, the present invention reminds a person of a security, safety, or health risk upon exiting a predetermined space. More particularly, the present invention reminds a person of an information security risk relating to sensitive, proprietary, confidential, trade secret, classified, or intellectual property information.

  20. ION SOURCE WITH SPACE CHARGE NEUTRALIZATION

    DOEpatents

    Flowers, J.W.; Luce, J.S.; Stirling, W.L.

    1963-01-22

    This patent relates to a space charge neutralized ion source in which a refluxing gas-fed arc discharge is provided between a cathode and a gas-fed anode to provide ions. An electron gun directs a controlled, monoenergetic electron beam through the discharge. A space charge neutralization is effected in the ion source and accelerating gap by oscillating low energy electrons, and a space charge neutralization of the source exit beam is effected by the monoenergetic electron beam beyond the source exit end. The neutralized beam may be accelerated to any desired energy at densities well above the limitation imposed by Langmuir-Child' s law. (AEC)

  1. Voice and choice in health care in England: understanding citizen responses to dissatisfaction.

    PubMed

    Dowding, Keith; John, Peter

    2011-01-01

    Using data from a five-year online survey the paper examines the effects of relative satisfaction with health services on individuals' voice-and-choice activity in the English public health care system. Voice is considered in three parts – individual voice (complaints), collective voice voting and participation (collective action). Exercising choice is seen in terms of complete exit (not using health care), internal exit (choosing another public service provider) and private exit (using private health care). The interaction of satisfaction and forms of voice and choice are analysed over time. Both voice and choice are correlated with dissatisfaction with those who are unhappy with the NHS more likely to privately voice and to plan to take up private health care. Those unable to choose private provision are likely to use private voice. These factors are not affected by items associated with social capital – indeed, being more trusting leads to lower voice activity.

  2. Optimal trajectories for the aeroassisted flight experiment. Part 3: Formulation, results, and analysis

    NASA Technical Reports Server (NTRS)

    Miele, A.; Wang, T.; Lee, W. Y.; Zhao, Z. G.

    1989-01-01

    The determination of optimal trajectories for the aero-assisted flight experiment (AFE) is investigated. The intent of this experiment is to simulate a GEO-to-LEO transfer, where GEO denotes a geosynchronous Earth orbit and LEO denotes a low Earth orbit. The trajectories of an AFE spacecraft are analyzed in a 3D-space, employing the full system of 6 ODEs describing the atmospheric pass. The atmospheric entry conditions are given, and the atmospheric exit conditions are adjusted in such a way that the following conditions are satisfied: (1) the atmospheric velocity depletion is such that, after exiting, the AFE spacecraft first ascends to a specified apogee and then descends to a specified perigee; and (2) the exit orbital plane is identical with the entry orbital plane. The final maneuver, not analyzed here, includes the rendezvous with and the capture by the space shuttle.

  3. Correction analysis for a supersonic water cooled total temperature probe tested to 1370 K

    NASA Technical Reports Server (NTRS)

    Lagen, Nicholas T.; Seiner, John M.

    1991-01-01

    The authors address the thermal analysis of a water cooled supersonic total temperature probe tested in a Mach 2 flow, up to 1366 K total temperature. The goal of this experiment was the determination of high-temperature supersonic jet mean flow temperatures. An 8.99 cm exit diameter water cooled nozzle was used in the tests. It was designed for exit Mach 2 at 1366 K exit total temperature. Data along the jet centerline were obtained for total temperatures of 755 K, 1089 K, and 1366 K. The data from the total temperature probe were affected by the water coolant. The probe was tested through a range of temperatures between 755 K and 1366 K with and without the cooling system turned on. The results were used to develop a relationship between the indicated thermocouple bead temperature and the freestream total temperature. The analysis and calculated temperatures are presented.

  4. 62. Refrigerator, microwave oven, equipment storage at top, north side ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    62. Refrigerator, microwave oven, equipment storage at top, north side - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  5. Monitoring weaving sections

    DOT National Transportation Integrated Search

    2001-10-01

    Traffic control in highway weaving sections is complicated since vehicles are crossing paths, changing lanes, or merging with through traffic as they enter or exit an expressway. There are two types of weaving sections: (a) single weaving sections wh...

  6. Fuzzy control for a nonlinear mimo-liquid level problem

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, R. E.; Mortensen, F. N.; Wantuck, P. J.

    2001-01-01

    Nonlinear systems are very common in the chemical process industries. Control of these systems, particularly multivariable systems, is extremely difficult. In many chemical plants, because of this difficulty, control is seldom optimal. Quite often, the best control is obtained in the manual mode using experienced operators. Liquid level control is probably one of the most common control problems in a chemical plant. Liquid level is important in heat exchanger control where heat and mass transfer rates can be controlled by the amount of liquid covering the tubes. Distillation columns, mixing tanks, and surge tanks are other examples where liquid levelmore » control is very important. The problem discussed in this paper is based on the simultaneous level control of three tanks connected in series. Each tank holds slightly less than 0.01 m{sup 3} of liquid. All three tanks are connected, Liquid is pumped into the first and the third tanks to maintain their levels. The third tank in the series drains to the system exit. The levels in the first and third tank control the level in the middle tank. The level in the middle tank affects the levels in the two end tanks. Many other chemical plant systems can be controlled in a manner similar to this three-tank system. For example, in any distillation column liquid level control problems can be represented as a total condenser with liquid level control, a reboiler with liquid level control, with the interactive column in between. The solution to the three-tank-problem can provide insight into many of the nonlinear control problems in the chemical process industries. The system was tested using the fuzzy logic controller and a proportional-integral (PI) controller, in both the setpoint tracking mode and disturbance rejection mode. The experimental results are discussed and comparisons between fuzzy controller and the standard PI controller are made.« less

  7. Adolescents Exiting Homelessness Over Two Years: The Risk Amplification and Abatement Model

    PubMed Central

    Milburn, Norweeta G.; Rice, Eric; Rotheram-Borus, Mary Jane; Mallett, Shelley; Rosenthal, Doreen; Batterham, Phillip; May, Susanne J.; Witkin, Andrea; Duan, Naihua

    2014-01-01

    The Risk Amplification and Abatement Model (RAAM), demonstrates that negative contact with socializing agents amplify risk, while positive contact abates risk for homeless adolescents. To test this model, the likelihood of exiting homelessness and returning to familial housing at 2 years and stably exiting over time are examined with longitudinal data collected from 183 newly homeless adolescents followed over 2 years in Los Angeles, CA. In support of RAAM, unadjusted odds of exiting at 2 years and stably exiting over2 years revealed that engagement with pro-social peers, maternal social support, and continued school attendance all promoted exiting behaviors. Simultaneously, exposure to family violence and reliance on shelter services discouraged stably exiting behaviors. Implications for family-based interventions are proposed. PMID:25067896

  8. 40 CFR 63.654 - Heat exchange systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... section. (1) All heat exchangers that are in organic HAP service within the heat exchange system that...., the heat exchange system does not contain any heat exchangers that are in organic HAP service as... exchange system in organic HAP service or from each heat exchanger exit line for each heat exchanger or...

  9. 40 CFR 63.654 - Heat exchange systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... section. (1) All heat exchangers that are in organic HAP service within the heat exchange system that...., the heat exchange system does not contain any heat exchangers that are in organic HAP service as... exchange system in organic HAP service or from each heat exchanger exit line for each heat exchanger or...

  10. 61. Upper panel in cornerpower panel lcpa lower panel in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    61. Upper panel in corner-power panel lcpa lower panel in corner-oxygen regeneration unit, at right-air conditioner control panel, on floor-bio-pack 45 for emergency breathing, looking northwest - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  11. Low-head feeding system for thin section castings

    DOEpatents

    Daniel, Sabah S.; Kleeb, Thomas R.; Lewis, Thomas W.; McDermott, John F.; Ozgu, Mustafa R.; Padfield, Ralph C.; Rego, Donovan N.; Vassilicos, Achilles

    1990-01-01

    A feed system is provided for conveying molten metal to a thin section caster having mold surfaces moving exclusively in the direction of casting. The feed system has a passage of circular cross section adjacent to one end thereof for receiving molten metal and a rectangular cross section at the delivery end thereof adjacent to the caster. The feed system is designed for supplying molten metal to the caster at low pressure for "closed-pool" type caster operation. The point of highest elevation in the metal flow passage of the feed system is on the upper surface of a transition portion where the cross section changes from circular to rectangular adjacent to the nozzle. The level or height of the high point above the centerline of the nozzle exit is selected so as to be less than the pressure of the metal measured in inches at the nozzle exit. This feature enables the maintenance of positive pressure in the metal within the feed system so that ingress of air into the metal is prevented.

  12. Pressurized tundish for controlling a continuous flow of molten metal

    DOEpatents

    Lewis, Thomas W.; Hamill, Jr., Paul E.; Ozgu, Mustafa R.; Padfield, Ralph C.; Rego, Donovan N.; Brita, Guido P.

    1990-01-01

    A pressurized tundish for controlling a continous flow of molten metal characterized by having a pair of principal compartments, one being essentially unpressurized and receiving molten metal introduced thereto, and the other being adapted for maintaining a controlled gaseous pressure over the surface of the fluid metal therein, whereby, by controlling the pressure within the pressurized chamber, metal exiting from the tundish is made to flow continually and at a controlled rate.

  13. Glacial conditioning of stream position and flooding in the braid plain of the Exit Glacier foreland, Alaska

    NASA Astrophysics Data System (ADS)

    Curran, Janet H.; Loso, Michael G.; Williams, Haley B.

    2017-09-01

    Flow spilling out of an active braid plain often signals the onset of channel migration or avulsion to previously occupied areas. In a recently deglaciated environment, distinguishing between shifts in active braid plain location, considered reversible by fluvial processes at short timescales, and more permanent glacier-conditioned changes in stream position can be critical to understanding flood hazards. Between 2009 and 2014, increased spilling from the Exit Creek braid plain in Kenai Fjords National Park, Alaska, repeatedly overtopped the only access road to the popular Exit Glacier visitor facilities and trails. To understand the likely cause of road flooding, we consider recent processes and the interplay between glacier and fluvial system dynamics since the maximum advance of the Little Ice Age, around 1815. Patterns of temperature and precipitation, the variables that drive high streamflow via snowmelt, glacier meltwater runoff, and rainfall, could not fully explain the timing of road floods. Comparison of high-resolution topographic data between 2008 and 2012 showed a strong pattern of braid plain aggradation along 3 km of glacier foreland, not unexpected at the base of mountainous glaciers and likely an impetus for channel migration. Historically, a dynamic zone follows the retreating glacier in which channel positions shift rapidly in response to changes in the glacier margin and fresh morainal deposits. This period of paraglacial adjustment lasts one to several decades at Exit Glacier. Subsequently, as moraine breaches consolidate and lock the channel into position, and as the stream regains the lower-elevation valley center, upper-elevation surfaces are abandoned as terraces inaccessible by fluvial processes for timescales of decades to centuries. Where not constrained by these terraces and moraines, the channel is free to migrate, which in this aggradational setting generates an alluvial fan at the breach of the final prominent moraine. The position of this fan is glacially conditioned but the process of migration of the braided channels across it is not. This broad perspective on channel controls identifies incipient avulsion into the roadside forest as part of a long-term fan-building process independent from changes in streamflow or sediment load.

  14. Radioactive Sediment Transport on Ogaki Dam Reservoir in Fukushima Evacuated Zone: Numerical Simulation Studies by 2-D River Simulation Code

    NASA Astrophysics Data System (ADS)

    Yamada, Susumu; Kitamura, Akihiro; Kurikami, Hiroshi; Machida, Masahiko

    2015-04-01

    Fukushima Daiichi Nuclear Power Plant (FDNPP) accident on March 2011 released significant quantities of radionuclides to atmosphere. The most significant nuclide is radioactive cesium isotopes. Therefore, the movement of the cesium is one of the critical issues for the environmental assessment. Since the cesium is strongly sorbed by soil particles, the cesium transport can be regarded as the sediment transport which is mainly brought about by the aquatic system such as a river and a lake. In this research, our target is the sediment transport on Ogaki dam reservoir which is located in about 16 km northwest from FDNPP. The reservoir is one of the principal irrigation dam reservoirs in Fukushima Prefecture and its upstream river basin was heavily contaminated by radioactivity. We simulate the sediment transport on the reservoir using 2-D river simulation code named Nays2D originally developed by Shimizu et al. (The latest version of Nays2D is available as a code included in iRIC (http://i-ric.org/en/), which is a river flow and riverbed variation analysis software package). In general, a 2-D simulation code requires a huge amount of calculation time. Therefore, we parallelize the code and execute it on a parallel computer. We examine the relationship between the behavior of the sediment transport and the height of the reservoir exit. The simulation result shows that almost all the sand that enter into the reservoir deposit close to the entrance of the reservoir for any height of the exit. The amounts of silt depositing within the reservoir slightly increase by raising the height of the exit. However, that of the clay dramatically increases. Especially, more than half of the clay deposits, if the exit is sufficiently high. These results demonstrate that the water level of the reservoir has a strong influence on the amount of the clay discharged from the reservoir. As a result, we conclude that the tuning of the water level has a possibility for controlling the recontamination to the downstream.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Breault, Ronald W.; Monazam, Esmail R.; Shadle, Lawrence J.

    Riser hydrodynamics are a function of the flow rates of gas and solids as well as the exit geometry, particularly when operated above the upper transport velocity. This work compares the exit voidage for multiple geometries and two different solids: Geldart group A glass beads and Geldart group B coke. Geometries were changed by modifying the volume of an abrupt T-shaped exit above the lateral riser exit. This was accomplished by positioning a plunger at various heights above the exit from zero to 0.38 m. A dimensionless expression used to predict smooth exit voidage was modified to account for themore » effect of the depth of the blind-T. The new correlation contains the solids-gas load ratio, solids-to-gas density ratio, bed-to-particle diameter ratio, gas Reynolds Number, as well as a term for the exit geometry. This study also found that there was a minimum riser roof height above the blind-T exit beyond which the riser exit voidage was not affected by the exit geometry. A correlation for this minimum riser roof height has also been developed in this study. This study covered riser superficial gas velocities of 4.35 to 7.7 m/s and solids circulation rates of 1.3 to 11.5 kg/s.« less

  16. Influence of drill helical direction on exit damage development in drilling carbon fiber reinforced plastic

    NASA Astrophysics Data System (ADS)

    Bai, Y.; Jia, Z. Y.; Wang, F. J.; Fu, R.; Guo, H. B.; Cheng, D.; Zhang, B. Y.

    2017-06-01

    Drilling is inevitable for CFRP components’ assembling process in the aviation industry. The exit damage frequently occurs and affects the load carrying capacity of components. Consequently, it is of great urgency to enhance drilling exit quality on CFRP components. The article aims to guide the reasonable choice of drill helical direction and effectively reduce exit damage. Exit observation experiments are carried out with left-hand helical, right-hand helical and straight one-shot drill drilling T800S CFRP laminates separately. The development rules of exit damage and delamination factor curves are obtained. Combined with loading conditions and fracture modes of push-out burrs, and thrust force curves, the influence of drill helical direction on exit damage development is derived. It is found that the main fracture modes for left-hand helical, right-hand helical, and straight one-shot drill are mode I, extrusive fracture, mode III respectively. Among them, mode III has the least effect on exit damage development. Meanwhile, the changing rate of thrust force is relative slow for right-hand helical and straight one-shot drill in the thrust force increasing phase of stage II, which is disadvantaged for exit damage development. Therefore, straight one-shot drill’s exit quality is the best.

  17. Bunch compression efficiency of the femtosecond electron source at Chiang Mai University

    NASA Astrophysics Data System (ADS)

    Thongbai, C.; Kusoljariyakul, K.; Saisut, J.

    2011-07-01

    A femtosecond electron source has been developed at the Plasma and Beam Physics Research Facility (PBP), Chiang Mai University (CMU), Thailand. Ultra-short electron bunches can be produced with a bunch compression system consisting of a thermionic cathode RF-gun, an alpha-magnet as a magnetic bunch compressor, and a linear accelerator as a post acceleration section. To obtain effective bunch compression, it is crucial to provide a proper longitudinal phase-space distribution at the gun exit matched to the subsequent beam transport system. Via beam dynamics calculations and experiments, we investigate the bunch compression efficiency for various RF-gun fields. The particle distribution at the RF-gun exit will be tracked numerically through the alpha-magnet and beam transport. Details of the study and results leading to an optimum condition for our system will be presented.

  18. Characterization of the Ignition Over-Pressure/Sound Suppression Water in the Space Launch System Mobile Launcher Using Volume of Fluid Modeling

    NASA Technical Reports Server (NTRS)

    West, Jeff

    2015-01-01

    The Space Launch System (SLS) Vehicle consists of a Core Stage with four RS-25 engines and two Solid Rocket Boosters (SRBs). This vehicle is launched from the Launchpad using a Mobile Launcher (ML) which supports the SLS vehicle until its liftoff from the ML under its own power. The combination of the four RS-25 engines and two SRBs generate a significant Ignition Over-Pressure (IOP) and Acoustic Sound environment. One of the mitigations of these environments is the Ignition Over-Pressure/Sound Suppression (IOP/SS) subsystem installed on the ML. This system consists of six water nozzles located parallel to and 24 inches downstream of each SRB nozzle exit plane as well as 16 water nozzles located parallel to and 53 inches downstream of the RS-25 nozzle exit plane. During launch of the SLS vehicle, water is ejected through each water nozzle to reduce the intensity of the transient pressure environment imposed upon the SLS vehicle. While required for the mitigation of the transient pressure environment on the SLS vehicle, the IOP/SS subsystem interacts (possibly adversely) with other systems located on the Launch Pad. One of the other systems that the IOP/SS water is anticipated to interact with is the Hydrogen Burn-Off Igniter System (HBOI). The HBOI system's purpose is to ignite the unburned hydrogen/air mixture that develops in and around the nozzle of the RS-25 engines during engine start. Due to the close proximity of the water system to the HBOI system, the presence of the IOP/SS may degrade the effectiveness of the HBOI system. Another system that the IOP/SS water may interact with adversely is the RS-25 engine nozzles and the SRB nozzles. The adverse interaction anticipated is the wetting, to a significant degree, of the RS-25 nozzles resulting in substantial weight of ice forming and water present to a significant degree upstream of the SRB nozzle exit plane inside the nozzle itself, posing significant additional blockage of the effluent that exits the nozzle upon motor start leading to detrimental effects. The purpose of the CFD simulations were to i) characterize the location of the IOP/SS water after it is ejected from the IOP/SS nozzles, ii) characterize the interaction of the IOP/SS system with the HBOI system and iii) characterize the interaction of the IOP/SS water with the RS-25 nozzles and the SRB nozzles.

  19. Intracellular pH regulation in rat round spermatids.

    PubMed

    Osses, N; Pancetti, F; Benos, D J; Reyes, J G

    1997-07-01

    Intracellular pH has been shown to be an important physiological parameter in cell cycle control and differentiation, aspects that are central to the spermatogenic process. However, the pH regulatory mechanisms in spermatogenic cells have not been systematically explored. In this work, measuring intracellular pH (pHi) with a fluorescent probe (BCECF), membrane potential with a fluorescent lipophilic anion (bisoxonol), and net movement of acid using a pH-stat system, we have found that rat round spermatids regulate pHi by means of a V-type H(+)-ATPase, a HCO3- entry pathway, a Na+/HCO3- dependent transport system, and a putative proton conductive pathway. Rat spermatids do not have functional base extruder transport systems. These pH regulatory characteristics seem specially designed to withstand acid challenges, and can generate sustained alkalinization upon acid exit stimulation.

  20. Palmitoylation of the β4-Subunit Regulates Surface Expression of Large Conductance Calcium-activated Potassium Channel Splice Variants*

    PubMed Central

    Chen, Lie; Bi, Danlei; Tian, Lijun; McClafferty, Heather; Steeb, Franziska; Ruth, Peter; Knaus, Hans Guenther; Shipston, Michael J.

    2013-01-01

    Regulatory β-subunits of large conductance calcium- and voltage-activated potassium (BK) channels play an important role in generating functional diversity and control of cell surface expression of the pore forming α-subunits. However, in contrast to α-subunits, the role of reversible post-translational modification of intracellular residues on β-subunit function is largely unknown. Here we demonstrate that the human β4-subunit is S-acylated (palmitoylated) on a juxtamembrane cysteine residue (Cys-193) in the intracellular C terminus of the regulatory β-subunit. β4-Subunit palmitoylation is important for cell surface expression and endoplasmic reticulum (ER) exit of the β4-subunit alone. Importantly, palmitoylated β4-subunits promote the ER exit and surface expression of the pore-forming α-subunit, whereas β4-subunits that cannot be palmitoylated do not increase ER exit or surface expression of α-subunits. Strikingly, however, this palmitoylation- and β4-dependent enhancement of α-subunit surface expression was only observed in α-subunits that contain a putative trafficking motif (… REVEDEC) at the very C terminus of the α-subunit. Engineering this trafficking motif to other C-terminal α-subunit splice variants results in α-subunits with reduced surface expression that can be rescued by palmitoylated, but not depalmitoylated, β4-subunits. Our data reveal a novel mechanism by which palmitoylated β4-subunit controls surface expression of BK channels through masking of a trafficking motif in the C terminus of the α-subunit. As palmitoylation is dynamic, this mechanism would allow precise control of specific splice variants to the cell surface. Our data provide new insights into how complex interplay between the repertoire of post-transcriptional and post-translational mechanisms controls cell surface expression of BK channels. PMID:23504458

  1. 2 MeV linear accelerator for industrial applications

    NASA Astrophysics Data System (ADS)

    Smith, Richard R.; Farrell, Sherman R.

    1997-02-01

    RPC Industries has developed a high average power scanned electron beam linac system for medium energy industrial processing, such as in-line sterilization. The parameters are: electron energy 2 MeV; average beam current 5.0 mA; and scanned width 0.5 meters. The control system features data logging and a Man-Machine Interface system. The accelerator is vertically mounted, the system height above the floor is 3.4 m, and the footprint is 0.9×1.2 meter2. The typical processing cell inside dimensions are 3.0 m by 3.5 m by 4.2 m high with concrete side walls 0.5 m thick above ground level. The equal exit depth dose is 0.73 gm cm-2. Additional topics that will be reported are: throughput, measurements of dose vs depth, dose uniformity across the web, and beam power by calorimeter and magnetic deflection of the beam.

  2. Utilization of available skills and materials in fire prevention

    NASA Technical Reports Server (NTRS)

    Martin, H. W.

    1971-01-01

    Procedures for installing fire protection systems in large buildings are discussed. Factors considered in the safety management are: (1) distribution of water supply, (2) design and location of exits, (3) emergency power system, and (4) maintenance procedures.

  3. Separase Is Required for Homolog and Sister Disjunction during Drosophila melanogaster Male Meiosis, but Not for Biorientation of Sister Centromeres.

    PubMed

    Blattner, Ariane C; Chaurasia, Soumya; McKee, Bruce D; Lehner, Christian F

    2016-04-01

    Spatially controlled release of sister chromatid cohesion during progression through the meiotic divisions is of paramount importance for error-free chromosome segregation during meiosis. Cohesion is mediated by the cohesin protein complex and cleavage of one of its subunits by the endoprotease separase removes cohesin first from chromosome arms during exit from meiosis I and later from the pericentromeric region during exit from meiosis II. At the onset of the meiotic divisions, cohesin has also been proposed to be present within the centromeric region for the unification of sister centromeres into a single functional entity, allowing bipolar orientation of paired homologs within the meiosis I spindle. Separase-mediated removal of centromeric cohesin during exit from meiosis I might explain sister centromere individualization which is essential for subsequent biorientation of sister centromeres during meiosis II. To characterize a potential involvement of separase in sister centromere individualization before meiosis II, we have studied meiosis in Drosophila melanogaster males where homologs are not paired in the canonical manner. Meiosis does not include meiotic recombination and synaptonemal complex formation in these males. Instead, an alternative homolog conjunction system keeps homologous chromosomes in pairs. Using independent strategies for spermatocyte-specific depletion of separase complex subunits in combination with time-lapse imaging, we demonstrate that separase is required for the inactivation of this alternative conjunction at anaphase I onset. Mutations that abolish alternative homolog conjunction therefore result in random segregation of univalents during meiosis I also after separase depletion. Interestingly, these univalents become bioriented during meiosis II, suggesting that sister centromere individualization before meiosis II does not require separase.

  4. Separase Is Required for Homolog and Sister Disjunction during Drosophila melanogaster Male Meiosis, but Not for Biorientation of Sister Centromeres

    PubMed Central

    Blattner, Ariane C.; McKee, Bruce D.; Lehner, Christian F.

    2016-01-01

    Spatially controlled release of sister chromatid cohesion during progression through the meiotic divisions is of paramount importance for error-free chromosome segregation during meiosis. Cohesion is mediated by the cohesin protein complex and cleavage of one of its subunits by the endoprotease separase removes cohesin first from chromosome arms during exit from meiosis I and later from the pericentromeric region during exit from meiosis II. At the onset of the meiotic divisions, cohesin has also been proposed to be present within the centromeric region for the unification of sister centromeres into a single functional entity, allowing bipolar orientation of paired homologs within the meiosis I spindle. Separase-mediated removal of centromeric cohesin during exit from meiosis I might explain sister centromere individualization which is essential for subsequent biorientation of sister centromeres during meiosis II. To characterize a potential involvement of separase in sister centromere individualization before meiosis II, we have studied meiosis in Drosophila melanogaster males where homologs are not paired in the canonical manner. Meiosis does not include meiotic recombination and synaptonemal complex formation in these males. Instead, an alternative homolog conjunction system keeps homologous chromosomes in pairs. Using independent strategies for spermatocyte-specific depletion of separase complex subunits in combination with time-lapse imaging, we demonstrate that separase is required for the inactivation of this alternative conjunction at anaphase I onset. Mutations that abolish alternative homolog conjunction therefore result in random segregation of univalents during meiosis I also after separase depletion. Interestingly, these univalents become bioriented during meiosis II, suggesting that sister centromere individualization before meiosis II does not require separase. PMID:27120695

  5. Large Eddy Simulation in a Channel with Exit Boundary Conditions

    NASA Technical Reports Server (NTRS)

    Cziesla, T.; Braun, H.; Biswas, G.; Mitra, N. K.

    1996-01-01

    The influence of the exit boundary conditions (vanishing first derivative of the velocity components and constant pressure) on the large eddy simulation of the fully developed turbulent channel flow has been investigated for equidistant and stretched grids at the channel exit. Results show that the chosen exit boundary conditions introduce some small disturbance which is mostly damped by the grid stretching. The difference between the fully developed turbulent channel flow obtained with LES with periodicity condition and the inlet and exit and the LES with fully developed flow at the inlet and the exit boundary condition is less than 10% for equidistant grids and less than 5% for the case grid stretching. The chosen boundary condition is of interest because it may be used in complex flows with backflow at exit.

  6. Integrating a Smartphone-Based Self-Management System into Usual Care of Advanced CKD.

    PubMed

    Ong, Stephanie W; Jassal, Sarbjit V; Miller, Judith A; Porter, Eveline C; Cafazzo, Joseph A; Seto, Emily; Thorpe, Kevin E; Logan, Alexander G

    2016-06-06

    Patient self-management has been shown to improve health outcomes. We developed a smartphone-based system to boost self-care by patients with CKD and integrated its use into usual CKD care. We determined its acceptability and examined changes in several clinical parameters. We recruited patients with stage 4 or 5 CKD attending outpatient renal clinics who responded to a general information newsletter about this 6-month proof-of-principle study. The smartphone application targeted four behavioral elements: monitoring BP, medication management, symptom assessment, and tracking laboratory results. Prebuilt customizable algorithms provided real-time personalized patient feedback and alerts to providers when predefined treatment thresholds were crossed or critical changes occurred. Those who died or started RRT within the first 2 months were replaced. Only participants followed for 6 months after recruitment were included in assessing changes in clinical measures. In total, 47 patients (26 men; mean age =59 years old; 33% were ≥65 years old) were enrolled; 60% had never used a smartphone. User adherence was high (>80% performed ≥80% of recommended assessments) and sustained. The mean reductions in home BP readings between baseline and exit were statistically significant (systolic BP, -3.4 mmHg; 95% confidence interval, -5.0 to -1.8 and diastolic BP, -2.1 mmHg; 95% confidence interval, -2.9 to -1.2); 27% with normal clinic BP readings had newly identified masked hypertension. One hundred twenty-seven medication discrepancies were identified; 59% were medication errors that required an intervention to prevent harm. In exit interviews, patients indicated feeling more confident and in control of their condition; clinicians perceived patients to be better informed and more engaged. Integrating a smartphone-based self-management system into usual care of patients with advanced CKD proved feasible and acceptable, and it appeared to be clinically useful. The results provide a strong rationale for a randomized, controlled trial. Copyright © 2016 by the American Society of Nephrology.

  7. Spatial Correlation in the Ambient Core Noise Field of a Turbofan Engine

    NASA Technical Reports Server (NTRS)

    Miles, Jeffrey Hilton

    2012-01-01

    An acoustic transfer function relating combustion noise and turbine exit noise in the presence of enclosed ambient core noise is investigated using a dynamic system model and an acoustic system model for the particular turbofan engine studied and for a range of operating conditions. Measurements of cross-spectra magnitude and phase between the combustor and turbine exit and auto-spectra at the turbine exit and combustor are used to show the presence of indirect and direct combustion noise over the frequency range of 0 400 Hz. The procedure used evaluates the ratio of direct to indirect combustion noise. The procedure used also evaluates the post-combustion residence time in the combustor which is a factor in the formation of thermal NOx and soot in this region. These measurements are masked by the ambient core noise sound field in this frequency range which is observable since the transducers are situated within an acoustic wavelength of one another. An ambient core noise field model based on one and two dimensional spatial correlation functions is used to replicate the spatially correlated response of the pair of transducers. The spatial correlation function increases measured attenuation due to destructive interference and masks the true attenuation of the turbine.

  8. Large amplitude forcing of a high speed 2-dimensional jet

    NASA Technical Reports Server (NTRS)

    Bernal, L.; Sarohia, V.

    1984-01-01

    The effect of large amplitude forcing on the growth of a high speed two dimensional jet was investigated experimentally. Two forcing techniques were utilized: mass flow oscillations and a mechanical system. The mass flow oscillation tests were conducted at Strouhal numbers from 0.00052 to 0.045, and peak to peak amplitudes up to 50 percent of the mean exit velocity. The exit Mach number was varied in the range 0.15 to 0.8. The corresponding Reynolds numbers were 8,400 and 45,000. The results indicate no significant change of the jet growth rate or centerline velocity decay compared to the undisturbed free jet. The mechanical forcing system consists of two counter rotating hexagonal cylinders located parallel to the span of the nozzle. Forcing frequencies up to 1,500 Hz were tested. Both symmetric and antisymmetric forcing can be implemented. The results for antisymmetric forcing showed a significant (75 percent) increase of the jet growth rate at an exit Mach number of 0.25 and a Strouhal number of 0.019. At higher rotational speeds, the jet deflected laterally. A deflection angle of 39 deg with respect to the centerline was measured at the maximum rotational speed.

  9. Leaving the labour market: the impact of exit routes from employment to retirement on health and wellbeing in old age.

    PubMed

    Halleröd, Björn; Örestig, Johan; Stattin, Mikael

    2013-03-01

    The study analyses whether and to what degree specific routes into retirement affect older people, i.e. the relationship between heterogeneous exit patterns and post-retirement health and wellbeing. We used longitudinal data from two points in time; data related to t 0 were collected in 1993, 1994, 1995 and 1996 and data related to t 1 were collected in 2002 and 2003 ( N  = 589). We focused on older people (55+ at t 1 ) who were employed at t 0 and retired at t 1 . We used confirmative factor analysis to identify identical measures of health and wellbeing at both t 0 and t 1 . Hence, we were able to control for pre-retirement health and wellbeing when evaluating the effects of different exit routes. These routes were defined as dependence on incomes from sickness benefit, disability pension, part-time pension, unemployment insurance and active labour market programmes. Our initial structural equation model showed a clear relation between exit routes and post-retirement wellbeing. People who prior to retirement were pushed into social benefit programmes related to health and unemployment were significantly worse off as retirees, especially those with health-related benefits. However, these relationships disappeared once pre-retirement wellbeing was added to the model. Our main conclusion is that post-retirement wellbeing first and foremost is a consequence of accumulation of advantages and disadvantages during the life course. Both labour market exit routes and post-retirement wellbeing can be seen as outcomes of this process. There are no independent effects of the retirement process. Judging from our findings, there is no reason to believe that involvement in social security programmes allowing early retirement on health grounds has any additional negative consequences for health and wellbeing.

  10. Use of Marijuana and Other Substances Among Pregnant and Parenting Women With Substance Use Disorders: Changes in Washington State After Marijuana Legalization.

    PubMed

    Grant, Therese M; Graham, J Christopher; Carlini, Beatriz H; Ernst, Cara C; Brown, Natalie Novick

    2018-01-01

    In 2012, possession of marijuana for nonmedical use was legalized in Washington State. This study examined how legalization affected alcohol and drug use in a sample of pregnant and parenting women with substance use disorders. Study participants from nine counties in Washington State (N = 1,359) were questioned about their substance use after completing a 3-year case management intervention program. The sample was divided into two cohorts based on whether participants had completed the program before or after legalization. Most study participants reported complete abstinence from alcohol and nonprescription drugs at program exit. Among those who were still using substances, women who completed the intervention after marijuana legalization were significantly more likely to report marijuana use at program exit compared with women who completed the intervention before marijuana legalization. Across both cohorts (pre- and post-legalization), we found a positive association of exit marijuana use with alcohol, illegal methadone, other opioids, amphetamines, and cocaine use; even when we controlled for historical period, the association with some of these substances with marijuana use remained evident. Independent of marijuana use, we saw increased use during the post-legalization period of alcohol, illicit methadone, and other opioids. Marijuana use at exit from the Parent-Child Assistance Program (PCAP) increased significantly after marijuana legalization in the state. Women who were not abstinent from marijuana at program exit were likely to report use of other substances as well. Our study design demonstrates an association but does not allow us to conclude that marijuana use leads to other substance use among this sample of women with a history of polysubstance use.

  11. 46. Communication equipment room, shock isolator air compressor at right, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. Communication equipment room, shock isolator air compressor at right, looking northeast - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  12. Substance abuse treatment engagement, completion and short-term outcomes in the Western Cape province, South Africa: Findings from the Service Quality Measures Initiative.

    PubMed

    Myers, Bronwyn; Williams, Petal Petersen; Govender, Rajen; Manderscheid, Ron; Koch, J Randy

    2018-04-01

    Optimizing the effectiveness of substance use disorder (SUD) treatment is critical in low-and middle-income countries (LMICs) with limited opportunities for SUD treatment. This is the first study to identify targets for interventions to improve the quality of SUD treatment in a LMIC. We explored correlates of three indicators of treatment quality (treatment engagement, completion and abstinence at treatment exit) using data from a SUD performance measurement system implemented in the Western Cape Province of South Africa. The sample included data from 1094 adult treatment episodes representing 53% of the treatment episodes in 2016. Using multivariate logistic regression analyses, we modeled socio-demographic, substance use and program correlates of treatment engagement, completion, and abstinence at treatment exit. Overall, 59% of patients completed treatment (48% of patients from outpatient services). Treatment completion was associated with greater likelihood of abstinence at treatment exit. Patients were more likely to complete treatment if they engaged in treatment, were older, and had more severe drug problems (characterized by daily drug use and heroin problems) and attended programs of shorter duration. Residential treatment was associated with greater likelihood of treatment engagement, completion, and abstinence at treatment exit. Improving rates of outpatient treatment completion will enhance the effectiveness of South Africa's SUD treatment system. Interventions that promote engagement in treatment, particularly among younger patients; reduce program length through referral to step-down continuing care; and ensure better matching of drug problem to treatment level and type could improve rates of treatment completion. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Ion-driven wind: Aerodynamics, performance limits, and optimization

    NASA Astrophysics Data System (ADS)

    Rickard, Matthew James Alan

    When a strong electric field is generated between a sharp, charged object and a grounded electrode in a gas medium, ions that are generated via a corona discharge near the tip of the sharp object migrate to the electrical ground, setting the neutral hulk gas in motion. The strength of the flow generated from such a process; known as a "corona", "ionic", or "ion-driven" wind, increases with electric field until electrical breakdown is reached. Previous studies have found an upper bound on the velocity of the ion-driven wind, even when a series of electrode stages are aggregated. With the intent of maximizing the gas flow front such devices, this dissertation describes a series of experiments that have been conducted and a numerical model that has been employed. Although typical hardware configurations include a wire parallel to a plate, a wire placed concentrically within a cylinder, or a needle facing a perpendicular plate or mesh, the chosen setup for this study is a needle facing a concentric ring. Using multiple experimental techniques and numerical simulation, velocity profiles have been observed at the ring exit and are sensitive to the design of the mounting hardware. The numerical model predicts the ideal electrode geometry for maximizing flow through a single unit. A modular, multi-staged system has been constructed and, when loaded with an exit nozzle, the exit velocity can be substantially increased. Further, if a small-scale (sub-millimeter) system is created, it is expected that the velocity will increase with multi-staging, even in the absence of an exit nozzle.

  14. Broadband pulsed flow using piezoelectric microjets

    NASA Astrophysics Data System (ADS)

    Hogue, Joshua; Solomon, John; Hays, Michael; Alvi, Farrukh; Oates, William

    2010-04-01

    A piezohydraulic microjet design and experimental results are presented to demonstrate broadband active flow control for applications on various aircraft structures including impinging jets, rotor blades, cavity bays, etc. The microjet actuator includes a piezoelectric stack actuator and hydraulic circuit that is used to throttle a 400 μm diameter microjet using hydraulic amplification of the piezoelectric stack actuator. This system is shown to provide broadband pulsed flow actuation up to 800 Hz. Unsteady pressure measurements of the microjet's exit flow are coupled with high-speed phase imagery using micro-Schlieren techniques to quantify the flow field. These results are compared with in situ stack actuator displacements using strain gauge measurements.

  15. EOS Terra Terra Constellation Exit/Future Maneuver Plans Update

    NASA Technical Reports Server (NTRS)

    Mantziaras, Dimitrios

    2016-01-01

    This EOS Terra Constellation Exit/Future Maneuver Plans Update presentation will discuss brief history of Terra EOM work; lifetime fuel estimates; baseline vs. proposed plan origin; resultant exit orbit; baseline vs. proposed exit plan; long term orbit altitude; revised lifetime proposal and fallback options.

  16. An APC/C-Cdh1 Biosensor Reveals the Dynamics of Cdh1 Inactivation at the G1/S Transition.

    PubMed

    Ondracka, Andrej; Robbins, Jonathan A; Cross, Frederick R

    2016-01-01

    B-type cyclin-dependent kinase activity must be turned off for mitotic exit and G1 stabilization. B-type cyclin degradation is mediated by the anaphase-promoting complex/cyclosome (APC/C); during and after mitotic exit, APC/C is dependent on Cdh1. Cdh1 is in turn phosphorylated and inactivated by cyclin-CDK at the Start transition of the new cell cycle. We developed a biosensor to assess the cell cycle dynamics of APC/C-Cdh1. Nuclear exit of the G1 transcriptional repressor Whi5 is a known marker of Start; APC/C-Cdh1 is inactivated 12 min after Whi5 nuclear exit with little measurable cell-to-cell timing variability. Multiple phosphorylation sites on Cdh1 act in a redundant manner to repress its activity. Reducing the number of phosphorylation sites on Cdh1 can to some extent be tolerated for cell viability, but it increases variability in timing of APC/C-Cdh1 inactivation. Mutants with minimal subsets of phosphorylation sites required for viability exhibit striking stochasticity in multiple responses including budding, nuclear division, and APC/C-Cdh1 activity itself. Multiple cyclin-CDK complexes, as well as the stoichiometric inhibitor Acm1, contribute to APC/C-Cdh1 inactivation; this redundant control is likely to promote rapid and reliable APC/C-Cdh1 inactivation immediately following the Start transition.

  17. Aircraft evacuations through type-III exits I : effects of seat placement at the exit.

    DOT National Transportation Integrated Search

    1995-07-01

    Simulated emergency egress from Type III over-wing exits was studied to support regulatory action by the FAA. Passageway width and seat encroachment distance adjacent to the Type-III exit were the major variables of interest. : Methods. Two subject g...

  18. 29 CFR 1910.36 - Design and construction requirements for exit routes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....36 Section 1910.36 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Exit Routes and Emergency Planning... of exit routes necessary for your workplace, consult NFPA 101-2000, Life Safety Code. (c) Exit...

  19. Safety and operational performance evaluation of four types of exit ramps on Florida's freeways (final report).

    DOT National Transportation Integrated Search

    2010-12-01

    This project mainly focuses on exit ramp performance analysis of safety and operations. In addition, issues of advance guide sign for exit ramp are also mentioned. : Safety analysis evaluates safety performances of different exit ramps used in Florid...

  20. Patients' Perceptions and Experiences of a mHealth Diabetes Self-management System.

    PubMed

    Georgsson, Mattias; Staggers, Nancy

    2017-03-01

    Chronic diseases, including diabetes, constitute a substantial disease burden around the world. Mobile self-management systems now play a significant and increasingly important role in patients' disease management. Yet, patients' perceptions of these systems after longer-term use are largely unexplored. A random sample of 10 diabetes patients was assessed immediately after they exited a larger, 6-month randomized controlled trial on the use of a mHealth system called Care4Life. This descriptive, exploratory study assessed patients' perceptions and experiences of mHealth using a questionnaire and semistructured interview whose development was guided by the Technology Acceptance Model. Results indicated that patients saw clear benefits in using the technology and had favorable behavioral disease outcomes after using Care4Life. Suggestions for improving the system were highly individual despite the apparent homogeneity of the patient group. The study begins to fill the gap about the longer-term use of mHealth systems in chronic disease management and reflects the significance of individual needs for mHealth systems.

  1. Process for Considering Special Exit Criteria from Bilingual/English as a Second Language (ESL) Services under 19 TAC §89.1225(k). School Year: 2013-2014, Grades 1-12

    ERIC Educational Resources Information Center

    Texas Education Agency, 2014

    2014-01-01

    Under Texas Administrative Code (TAC) §89.1225(h), districts are required to use the exit criteria represented in the chart titled "2013-2014 English Proficiency Exit Criteria Chart" found at (http://www.tea.state.tx.us/index2.aspx?id=4098) to exit English language learners (ELLs) from bilingual/ESL programs. The exit criteria under TAC…

  2. The effect of riser end geometry on gas-solid hydrodynamics in a CFB riser operating in the core annular and dilute homogeneous flow regimes

    DOE PAGES

    Breault, Ronald W.; Monazam, Esmail R.; Shadle, Lawrence J.; ...

    2017-02-12

    Riser hydrodynamics are a function of the flow rates of gas and solids as well as the exit geometry, particularly when operated above the upper transport velocity. This work compares the exit voidage for multiple geometries and two different solids: Geldart group A glass beads and Geldart group B coke. Geometries were changed by modifying the volume of an abrupt T-shaped exit above the lateral riser exit. This was accomplished by positioning a plunger at various heights above the exit from zero to 0.38 m. A dimensionless expression used to predict smooth exit voidage was modified to account for themore » effect of the depth of the blind-T. The new correlation contains the solids-gas load ratio, solids-to-gas density ratio, bed-to-particle diameter ratio, gas Reynolds Number, as well as a term for the exit geometry. This study also found that there was a minimum riser roof height above the blind-T exit beyond which the riser exit voidage was not affected by the exit geometry. A correlation for this minimum riser roof height has also been developed in this study. This study covered riser superficial gas velocities of 4.35 to 7.7 m/s and solids circulation rates of 1.3 to 11.5 kg/s.« less

  3. Underwater detectibility of a lighting system on a helicopter escape exit.

    PubMed

    O'Neill, Brendan D; Kozey, John W; Brooks, Chris J

    2004-06-01

    When a helicopter ditches into water, it immediately inverts due to the weight of the engines and then fills with water. Locating the emergency exit for escape under such conditions is a difficult task. A new lighting system for an escape exit has been developed that illuminates on contact with water. The detectibility of the lighting was investigated under varying conditions of ambient illumination, water turbidity, and viewing distance. A total of 288 underwater detection trials were carried out by 9 subjects with an illuminated hatch placed at 2 distances (1.5 m and 3.1 m), under 2 ambient illuminations (bright: > 3000 lux and dark: < 0.1 lux), and in 2 conditions of water turbidity. The water temperature was 12 degrees C for all conditions. At 1.5 m, the lighting system was detectable in less than 1.5 s by all subjects in both clear and turbid water and under both bright and dark conditions. At 3.1 m, the lights were detectable in both clear and turbid water under the dark condition and in clear water under the bright condition. However, the lighting was not reliably detected in turbid water under bright condition. The system met original design requirements in terms of detectibility at 1.5 m. The detection time was always under 1.5 s. It could also be detected at 3.1 m in clear and turbid water, under dark conditions. However, the detectibility at 3.1 m in turbid water, under bright condition was less reliable.

  4. Pressurized tundish for controlling a continuous flow of molten metal

    DOEpatents

    Lewis, T.W.; Hamill, P.E. Jr.; Ozgu, M.R.; Padfield, R.C.; Rego, D.N.; Brita, G.P.

    1990-07-24

    A pressurized tundish for controlling a continuous flow of molten metal is characterized by having a pair of principal compartments, one being essentially unpressurized and receiving molten metal introduced thereto, and the other being adapted for maintaining a controlled gaseous pressure over the surface of the fluid metal therein, whereby, by controlling the pressure within the pressurized chamber, metal exiting from the tundish is made to flow continually and at a controlled rate. 1 fig.

  5. 40 CFR 63.654 - Heat exchange systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) through (g) of this section if all heat exchangers within the heat exchange system either: (1) Operate... exposure to air for each heat exchange system. (ii) Selected heat exchanger exit line(s) so that each heat exchanger or group of heat exchangers within a heat exchange system is covered by the selected monitoring...

  6. 40 CFR 63.654 - Heat exchange systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) through (g) of this section if all heat exchangers within the heat exchange system either: (1) Operate... exposure to air for each heat exchange system. (ii) Selected heat exchanger exit line(s) so that each heat exchanger or group of heat exchangers within a heat exchange system is covered by the selected monitoring...

  7. Factors Associated With Premature Exits From Supported Housing.

    PubMed

    Gabrielian, Sonya; Burns, Alaina V; Nanda, Nupur; Hellemann, Gerhard; Kane, Vincent; Young, Alexander S

    2016-01-01

    Many homeless consumers who enroll in supported housing programs--which offer subsidized housing and supportive services--disengage prematurely, before placement in permanent community-based housing. This study explored factors associated with exiting a supported housing program before achieving housing placement. With the use of administrative data, a roster was obtained for consumers enrolled in the Veterans Affairs (VA) Greater Los Angeles supported housing program from 2011 to 2012. Fewer (4%) consumers exited this program before achieving housing ("exiters") compared with consumers described in national VA figures (18%). Exiters with available demographic data (N=51) were matched 1:1 on age, gender, marital status, and race-ethnicity with consumers housed through this program ("stayers," N=51). Medical records were reviewed to compare diagnoses, health care utilization, housing histories, vocational history, and criminal justice involvement of exiters versus stayers. Exiters' housing outcomes were identified. Recursive partitioning identified variables that best differentiated exiters from stayers. Several factors were associated with premature exits from this supported housing program: residing in temporary housing on hospital grounds during program enrollment, poor adherence to outpatient care, substance use disorders, hepatitis C, chronic pain, justice involvement, frequent emergency department utilization, and medical-surgical admissions. The first of these factors and poor adherence to outpatient medical-surgical care best differentiated exiters from stayers. Moreover, >50% of exiters became street homeless or incarcerated after leaving the program. In that diverse social factors, diagnoses, and health care utilization patterns were associated with premature disengagement from supported housing, future research is needed to implement and evaluate rehabilitative services that address these factors, adapted to the context of supported housing.

  8. 34 CFR 682.604 - Required exit counseling for borrowers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 4 2014-07-01 2014-07-01 false Required exit counseling for borrowers. 682.604 Section... counseling for borrowers. (a) Exit counseling. (1) A school must ensure that exit counseling is conducted... ensure that this counseling is conducted shortly before the student borrower ceases at least half-time...

  9. High-speed monodisperse droplet generation by ultrasonically controlled micro-jet breakup

    NASA Astrophysics Data System (ADS)

    Frommhold, Philipp Erhard; Lippert, Alexander; Holsteyns, Frank Ludwig; Mettin, Robert

    2014-04-01

    A liquid jet that is ejected from a nozzle into air will disintegrate into drops via the well-known Plateau-Rayleigh instability within a certain range of Ohnesorge and Reynolds numbers. With the focus on the micrometer scale, we investigate the control of this process by superimposing a suitable ultrasonic signal, which causes the jet to break up into a very precise train of monodisperse droplets. The jet leaves a pressurized container of liquid via a small orifice of about 20 μm diameter. The break-up process and the emerging droplets are recorded via high-speed imaging. An extended parameter study of exit speed and ultrasonic frequency is carried out for deionized water to evaluate the jet's state and the subsequent generation of monodisperse droplets. Maximum exit velocities obtained reach almost 120 m s-1, and frequencies have been applied up to 1.8 MHz. Functionality of the method is confirmed for five additional liquids for moderate jet velocities 38 m s-1. For the uncontrolled jet disintegration, the drop size spectra revealed broad distributions and downstream drop growth by collision, while the acoustic control generated monodisperse droplets with a standard deviation less than 0.5 %. By adjustment of the acoustic excitation frequency, drop diameters could be tuned continuously from about 30 to 50 μm for all exit speeds. Good agreement to former experiments and theoretical approaches is found for the relation of overpressure and jet exit speed, and for the observed stability regions of monodisperse droplet generation in the parameter plane of jet speed and acoustic excitation frequency. Fitting of two free parameters of the general theory to the liquids and nozzles used is found to yield an even higher precision. Furthermore, the high-velocity instability limit of regular jet breakup described by von Ohnesorge has been superseded by more than a factor of two without entering the wind-induced instability regime, and monodisperse droplet generation was always achievable. Thus, the reliable and robust realization of tunable high-speed monodisperse micro-droplet trains is demonstrated. Some implication for applications is discussed.

  10. Raman efficiencies of natural rocks and minerals: performance of a remote Raman system for planetary exploration at a distance of 10 meters.

    PubMed

    Stopar, Julie D; Lucey, Paul G; Sharma, Shiv K; Misra, Anupam K; Taylor, G Jeffrey; Hubble, Hugh W

    2005-08-01

    Raman spectroscopy is a powerful technique for materials analysis, and we are developing and analyzing a remote Raman system for use on a planetary lander or rover. We have acquired data at a distance of 10m from a variety of geologic materials using different instrument designs. We have employed a pulsed laser with both an ungated detector and a gated detector. A gated detector can reduce long-lived fluorescence while still collecting all Raman signal. In order to design a flight instrument, we need to quantify how natural surfaces will respond to laser stimulus. We define remote Raman efficiency of natural surfaces as the ratio of radiant exitance leaving a natural surface to the irradiance of the incident laser. The radiant exitance of a natural surface is the product of the sample radiance, the projected solid angle, and the full-width-half-maximum of the Raman signal. We have determined the remote Raman efficiency for a variety of rocks and minerals. The best efficiencies are achieved for large, clear, single crystals that produce the most radiant exitance, while darker fine-grained mineral mixtures produce lower efficiencies. By implementing a pulsed laser, gated detector system we have improved the signal detection and have generally decreased the integration time necessary to detect Raman signal from natural surfaces.

  11. Record Dynamics in Ants

    PubMed Central

    Richardson, Thomas O.; Robinson, Elva J. H.; Christensen, Kim; Jensen, Henrik J.; Franks, Nigel R.; Sendova-Franks, Ana B.

    2010-01-01

    The success of social animals (including ourselves) can be attributed to efficiencies that arise from a division of labour. Many animal societies have a communal nest which certain individuals must leave to perform external tasks, for example foraging or patrolling. Staying at home to care for young or leaving to find food is one of the most fundamental divisions of labour. It is also often a choice between safety and danger. Here we explore the regulation of departures from ant nests. We consider the extreme situation in which no one returns and show experimentally that exiting decisions seem to be governed by fluctuating record signals and ant-ant interactions. A record signal is a new ‘high water mark’ in the history of a system. An ant exiting the nest only when the record signal reaches a level it has never perceived before could be a very effective mechanism to postpone, until the last possible moment, a potentially fatal decision. We also show that record dynamics may be involved in first exits by individually tagged ants even when their nest mates are allowed to re-enter the nest. So record dynamics may play a role in allocating individuals to tasks, both in emergencies and in everyday life. The dynamics of several complex but purely physical systems are also based on record signals but this is the first time they have been experimentally shown in a biological system. PMID:20300174

  12. Prediction of efficacy for conversion from adjunctive therapy to monotherapy with eslicarbazepine acetate 800 mg once daily for partial-onset epilepsy

    PubMed Central

    Sunkaraneni, Soujanya; Passarell, Julie A; Ludwig, Elizabeth A; Fiedler-Kelly, Jill; Pitner, Janet K; Grinnell, Todd A; Blum, David

    2017-01-01

    Purpose Eslicarbazepine acetate (ESL) is a once-daily (QD) oral antiepileptic drug (AED) indicated for partial-onset seizures (POS). Clinical studies of gradual conversion to ESL 1,200 and 1,600 mg QD monotherapies were previously conducted in patients with POS who were not well-controlled by 1 or 2 AEDs. This report describes modeling and simulation of plasma eslicarbazepine (primary active metabolite of ESL) concentrations and time to monotherapy study exit to predict efficacy for conversion to ESL monotherapy at a lower dose of 800 mg, as an option for patients requiring or not tolerating higher doses since this regimen is effective in adjunctive therapy for POS. Patients and methods A previously developed population pharmacokinetic model for ESL monotherapy was used to predict minimum plasma eslicarbazepine concentration (Cmin) in 1,500 virtual patients taking 1 (n=1,000) or 2 (n=500) AEDs at baseline, treated with ESL 400 mg QD for 1 week, followed by 800 mg QD for 17 weeks (similar to ESL monotherapy trials where the other AEDs were withdrawn during the first 6 weeks following titration to the randomized ESL dose). Model-predicted Cmin as a time-varying covariate and number of baseline AEDs were used to determine the weekly probability of each patient meeting exit criteria (65.3% threshold) indicative of worsening seizure control in 500 simulated ESL monotherapy trials. A previously developed extended Cox proportional hazards exposure–response model was used to relate time-varying eslicarbazepine exposure to the time to study exit. Results For virtual patients receiving ESL monotherapy (800 mg QD), the 95% upper prediction limit for exit rate at 112 days of 34.9% in patients taking 1 AED at baseline was well below the 65.3% threshold from historical control trials, while the estimate for patients taking 2 AEDs (70.6%) was slightly above the historical control threshold. Conclusion This model-based assessment supports conversion to ESL 800 mg QD monotherapy for POS in adults taking 1 AED. For patients taking 2 concomitant AEDs, however, prescribers should consider maintenance doses of 1,200 or 1,600 mg ESL QD to reduce the likelihood of seizure worsening if conversion to ESL monotherapy is contemplated. PMID:28721105

  13. Prediction of efficacy for conversion from adjunctive therapy to monotherapy with eslicarbazepine acetate 800 mg once daily for partial-onset epilepsy.

    PubMed

    Sunkaraneni, Soujanya; Passarell, Julie A; Ludwig, Elizabeth A; Fiedler-Kelly, Jill; Pitner, Janet K; Grinnell, Todd A; Blum, David

    2017-01-01

    Eslicarbazepine acetate (ESL) is a once-daily (QD) oral antiepileptic drug (AED) indicated for partial-onset seizures (POS). Clinical studies of gradual conversion to ESL 1,200 and 1,600 mg QD monotherapies were previously conducted in patients with POS who were not well-controlled by 1 or 2 AEDs. This report describes modeling and simulation of plasma eslicarbazepine (primary active metabolite of ESL) concentrations and time to monotherapy study exit to predict efficacy for conversion to ESL monotherapy at a lower dose of 800 mg, as an option for patients requiring or not tolerating higher doses since this regimen is effective in adjunctive therapy for POS. A previously developed population pharmacokinetic model for ESL monotherapy was used to predict minimum plasma eslicarbazepine concentration ( C min ) in 1,500 virtual patients taking 1 (n=1,000) or 2 (n=500) AEDs at baseline, treated with ESL 400 mg QD for 1 week, followed by 800 mg QD for 17 weeks (similar to ESL monotherapy trials where the other AEDs were withdrawn during the first 6 weeks following titration to the randomized ESL dose). Model-predicted C min as a time-varying covariate and number of baseline AEDs were used to determine the weekly probability of each patient meeting exit criteria (65.3% threshold) indicative of worsening seizure control in 500 simulated ESL monotherapy trials. A previously developed extended Cox proportional hazards exposure-response model was used to relate time-varying eslicarbazepine exposure to the time to study exit. For virtual patients receiving ESL monotherapy (800 mg QD), the 95% upper prediction limit for exit rate at 112 days of 34.9% in patients taking 1 AED at baseline was well below the 65.3% threshold from historical control trials, while the estimate for patients taking 2 AEDs (70.6%) was slightly above the historical control threshold. This model-based assessment supports conversion to ESL 800 mg QD monotherapy for POS in adults taking 1 AED. For patients taking 2 concomitant AEDs, however, prescribers should consider maintenance doses of 1,200 or 1,600 mg ESL QD to reduce the likelihood of seizure worsening if conversion to ESL monotherapy is contemplated.

  14. Recent radial turbine research at the NASA Lewis Research Center.

    NASA Technical Reports Server (NTRS)

    Rohlik, H. E.; Kofskey, M. G.

    1972-01-01

    The major results obtained in several recent experimental programs on small radial inflow turbines for space applications are presented and discussed. Specifically, experimental and analytical work associated with these systems that has included examination of blade-shroud clearance, blade loading, and exit diffuser design, is considered. Results indicate high efficiency over a wide range of specific speed, and also insensitivity to clearance and blade loading in the radial part of the rotor. The exit diffuser investigation indicated that a conventional conical outer wall may not provide the velocity variation consistent with minimum overall diffuser loss.

  15. The ground vortex flow field associated with a jet in a cross flow impinging on a ground plane for uniform and annular turbulent axisymmetric jets. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Cavage, William M.; Kuhlman, John M.

    1993-01-01

    An experimental study was conducted of the impingement of a single circular jet on a ground plane in a cross flow. This geometry is a simplified model of the interaction of propulsive jet exhaust from a V/STOL aircraft with the ground in forward flight. Jets were oriented normal to the cross flow and ground plane. Jet size, cross flow-to-jet velocity ratio, ground plane-to-jet board spacing, and jet exit turbulence level and mean velocity profile shape were all varied to determine their effects on the size of the ground vortex interaction region which forms on the ground plane, using smoke injection into the jet. Three component laser Doppler velocimeter measurements were made with a commercial three color system for the case of a uniform jet with exit spacing equal to 5.5 diameters and cross flow-to-jet velocity ratio equal to 0.11. The flow visualization data compared well for equivalent runs of the same nondimensional jet exit spacing and the same velocity ratio for different diameter nozzles, except at very low velocity ratios and for the larger nozzle, where tunnel blockage became significant. Variation of observed ground vortex size with cross flow-to-jet velocity ratio was consistent with previous studies. Observed effects of jet size and ground plane-to-jet board spacing were relatively small. Jet exit turbulence level effects were also small. However, an annular jet with a low velocity central core was found to have a significantly smaller ground vortex than an equivalent uniform jet at the same values of cross flow-to-jet velocity ratio and jet exit-to-ground plane spacing. This may suggest a means of altering ground vortex behavior somewhat, and points out the importance of proper simulation of jet exit velocity conditions. LV data indicated unsteady turbulence levels in the ground vortex in excess of 70 percent.

  16. Probability of growth of small damage sites on the exit surface of fused silica optics.

    PubMed

    Negres, Raluca A; Abdulla, Ghaleb M; Cross, David A; Liao, Zhi M; Carr, Christopher W

    2012-06-04

    Growth of laser damage on fused silica optical components depends on several key parameters including laser fluence, wavelength, pulse duration, and site size. Here we investigate the growth behavior of small damage sites on the exit surface of SiO₂ optics under exposure to tightly controlled laser pulses. Results demonstrate that the onset of damage growth is not governed by a threshold, but is probabilistic in nature and depends both on the current size of a damage site and the laser fluence to which it is exposed. We also develop models for use in growth prediction. In addition, we show that laser exposure history also influences the behavior of individual sites.

  17. The effectiveness of alternative planned durations of residential drug abuse treatment.

    PubMed Central

    McCusker, J; Vickers-Lahti, M; Stoddard, A; Hindin, R; Bigelow, C; Zorn, M; Garfield, F; Frost, R; Love, C; Lewis, B

    1995-01-01

    Randomized controlled trials were conducted at two residential drug abuse treatment facilities to compare programs that differed in planned duration. One trial compared a 6-month and a 12-month therapeutic community program (n = 184), and the second compared a 3-month and a 6-month relapse prevention program (n = 444). Retention rates over comparable time periods differed minimally by planned treatment duration, and the longer programs had lower completion rates. There was no effect in either trial of planned treatment duration on changes in psychosocial variables between admission and exit or on rates or patterns of drug use at follow-up between 2 and 6 months after exit. PMID:7573630

  18. Do changes in the labour market take families out of poverty? Determinants of exiting poverty in Brazilian metropolitan regions.

    PubMed

    Machado, Ana Flavia; Ribas, Rafael Perez Ribas

    2010-01-01

    Using survival models, we test whether short-term changes in the labour market affect poverty duration. Data are from the Brazilian Monthly Employment Survey. Such a monthly dataset permits more accurate estimations of events than using annual data, but its panel follows households for a short period. Then methods that control for both right- and left-censoring should be used. The results are as follows: households with zero income are not those with the lowest chances of exiting; changes in aggregate unemployment do not affect poverty duration; and increasing wages in the informal sector has a negative effect on poverty duration.

  19. Use of exit examinations: a criterion for graduation?

    PubMed

    Cullen, P D

    1997-01-01

    This study sought to measure the use of exit examinations in nursing schools at Historically Black Colleges and Universities (HBCU). Fifteen participants from HBCU nursing schools throughout the United States were surveyed to determine current practices related to exit exams. Overall, fourteen schools (93.33%) used an exit exam at the end of their nursing program. However, 73.33% of the participants (11 schools) reported it was mandatory for students to pass the exam as a requirement for graduation. Almost 47% of the participants (7 schools) reported the use of the exit exam was related to NCLEX-RN pass rates, while others reported identification of student needs as the primary reason for using an exit exam. Most participants were very helpful by sharing their innovations. While this small study provided some information on the use of exit examinations, more research is needed to substantiate both the appropriateness and usefulness of their use in baccalaureate degree nursing programs.

  20. Spatial signals link exit from mitosis to spindle position.

    PubMed

    Falk, Jill Elaine; Tsuchiya, Dai; Verdaasdonk, Jolien; Lacefield, Soni; Bloom, Kerry; Amon, Angelika

    2016-05-11

    In budding yeast, if the spindle becomes mispositioned, cells prevent exit from mitosis by inhibiting the mitotic exit network (MEN). The MEN is a signaling cascade that localizes to spindle pole bodies (SPBs) and activates the phosphatase Cdc14. There are two competing models that explain MEN regulation by spindle position. In the 'zone model', exit from mitosis occurs when a MEN-bearing SPB enters the bud. The 'cMT-bud neck model' posits that cytoplasmic microtubule (cMT)-bud neck interactions prevent MEN activity. Here we find that 1) eliminating cMT- bud neck interactions does not trigger exit from mitosis and 2) loss of these interactions does not precede Cdc14 activation. Furthermore, using binucleate cells, we show that exit from mitosis occurs when one SPB enters the bud despite the presence of a mispositioned spindle. We conclude that exit from mitosis is triggered by a correctly positioned spindle rather than inhibited by improper spindle position.

  1. Stochastic modelling of temperatures affecting the in situ performance of a solar-assisted heat pump: The multivariate approach and physical interpretation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loveday, D.L.; Craggs, C.

    Box-Jenkins-based multivariate stochastic modeling is carried out using data recorded from a domestic heating system. The system comprises an air-source heat pump sited in the roof space of a house, solar assistance being provided by the conventional tile roof acting as a radiation absorber. Multivariate models are presented which illustrate the time-dependent relationships between three air temperatures - at external ambient, at entry to, and at exit from, the heat pump evaporator. Using a deterministic modeling approach, physical interpretations are placed on the results of the multivariate technique. It is concluded that the multivariate Box-Jenkins approach is a suitable techniquemore » for building thermal analysis. Application to multivariate Box-Jenkins approach is a suitable technique for building thermal analysis. Application to multivariate model-based control is discussed, with particular reference to building energy management systems. It is further concluded that stochastic modeling of data drawn from a short monitoring period offers a means of retrofitting an advanced model-based control system in existing buildings, which could be used to optimize energy savings. An approach to system simulation is suggested.« less

  2. Tripartite assembly of RND multidrug efflux pumps

    NASA Astrophysics Data System (ADS)

    Daury, Laetitia; Orange, François; Taveau, Jean-Christophe; Verchère, Alice; Monlezun, Laura; Gounou, Céline; Marreddy, Ravi K. R.; Picard, Martin; Broutin, Isabelle; Pos, Klaas M.; Lambert, Olivier

    2016-02-01

    Tripartite multidrug efflux systems of Gram-negative bacteria are composed of an inner membrane transporter, an outer membrane channel and a periplasmic adaptor protein. They are assumed to form ducts inside the periplasm facilitating drug exit across the outer membrane. Here we present the reconstitution of native Pseudomonas aeruginosa MexAB-OprM and Escherichia coli AcrAB-TolC tripartite Resistance Nodulation and cell Division (RND) efflux systems in a lipid nanodisc system. Single-particle analysis by electron microscopy reveals the inner and outer membrane protein components linked together via the periplasmic adaptor protein. This intrinsic ability of the native components to self-assemble also leads to the formation of a stable interspecies AcrA-MexB-TolC complex suggesting a common mechanism of tripartite assembly. Projection structures of all three complexes emphasize the role of the periplasmic adaptor protein as part of the exit duct with no physical interaction between the inner and outer membrane components.

  3. System to continuously produce carbon fiber via microwave assisted plasma processing

    DOEpatents

    White, Terry L [Knoxville, TN; Paulauskas, Felix L [Knoxville, TN; Bigelow, Timothy S [Knoxville, TN

    2010-11-02

    A system to continuously produce fully carbonized or graphitized carbon fibers using microwave-assisted plasma (MAP) processing comprises an elongated chamber in which a microwave plasma is excited in a selected gas atmosphere. Fiber is drawn continuously through the chamber, entering and exiting through openings designed to minimize in-leakage of air. There is a gradient of microwave power within the chamber with generally higher power near where the fiber exits and lower power near where the fiber enters. Polyacrylonitrile (PAN), pitch, or any other suitable organic/polymeric precursor fibers can be used as a feedstock for the inventive system. Oxidized or partially oxidized PAN or pitch or other polymeric fiber precursors are run continuously through a MAP reactor in an inert, non-oxidizing atmosphere to heat the fibers, drive off the unwanted elements such as oxygen, nitrogen, and hydrogen, and produce carbon or graphite fibers faster than conventionally produced carbon fibers.

  4. 46 CFR 185.606 - Escape hatches and emergency exits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Escape hatches and emergency exits. 185.606 Section 185... 100 GROSS TONS) OPERATIONS Markings Required § 185.606 Escape hatches and emergency exits. All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible...

  5. 46 CFR 185.606 - Escape hatches and emergency exits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Escape hatches and emergency exits. 185.606 Section 185... 100 GROSS TONS) OPERATIONS Markings Required § 185.606 Escape hatches and emergency exits. All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible...

  6. 46 CFR 185.606 - Escape hatches and emergency exits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Escape hatches and emergency exits. 185.606 Section 185... 100 GROSS TONS) OPERATIONS Markings Required § 185.606 Escape hatches and emergency exits. All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible...

  7. 46 CFR 185.606 - Escape hatches and emergency exits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Escape hatches and emergency exits. 185.606 Section 185... 100 GROSS TONS) OPERATIONS Markings Required § 185.606 Escape hatches and emergency exits. All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible...

  8. 46 CFR 185.606 - Escape hatches and emergency exits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Escape hatches and emergency exits. 185.606 Section 185... 100 GROSS TONS) OPERATIONS Markings Required § 185.606 Escape hatches and emergency exits. All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible...

  9. An Entrance to Exit Polling: Strategies for Using Exit Polls as Experiential Learning Projects

    ERIC Educational Resources Information Center

    Berry, Michael J.; Robinson, Tony

    2012-01-01

    Engaging students in the design, administration, and postelection analysis of an exit poll can be an excellent experiential learning activity. Lelieveldt and Rossen (2009) argue that exit polls are a "perfect teaching tool" because they provide students with a cooperative (rather than competitive) learning experience; help students…

  10. 40 CFR 63.3176 - What definitions apply to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... automobiles or light-duty trucks, including coating facilities and processes. Bake oven air seal means an entry or entry vestibule to or an exit or exit vestibule from a bake oven which isolates the bake oven... exit or exit vestibule) the bake oven. No significant VOC generating activity takes place in a bake...

  11. Exit Cards: Creating a Dialogue for Continuous Evaluation

    ERIC Educational Resources Information Center

    Patka, Mazna; Wallin-Ruschman, Jennifer; Wallace, Tenille; Robbins, Candice

    2016-01-01

    This study explored the use of Exit Cards, which are formative evaluations of student knowledge and instruction undertaken at every class meeting. Its results are based on Exit Card data from two undergraduate research methods courses. Thematic analysis indicated that students used Exit Cards to communicate (1) what they learned, (2) challenges…

  12. 8 CFR 215.9 - Temporary Worker Visa Exit Program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 8 Aliens and Nationality 1 2011-01-01 2011-01-01 false Temporary Worker Visa Exit Program. 215.9... ALIENS DEPARTING FROM THE UNITED STATES § 215.9 Temporary Worker Visa Exit Program. An alien admitted on certain temporary worker visas at a port of entry participating in the Temporary Worker Visa Exit Program...

  13. 8 CFR 215.9 - Temporary Worker Visa Exit Program.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Temporary Worker Visa Exit Program. 215.9... ALIENS DEPARTING FROM THE UNITED STATES § 215.9 Temporary Worker Visa Exit Program. An alien admitted on certain temporary worker visas at a port of entry participating in the Temporary Worker Visa Exit Program...

  14. 8 CFR 215.9 - Temporary Worker Visa Exit Program.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 8 Aliens and Nationality 1 2013-01-01 2013-01-01 false Temporary Worker Visa Exit Program. 215.9... ALIENS DEPARTING FROM THE UNITED STATES § 215.9 Temporary Worker Visa Exit Program. An alien admitted on certain temporary worker visas at a port of entry participating in the Temporary Worker Visa Exit Program...

  15. 8 CFR 215.9 - Temporary Worker Visa Exit Program.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 8 Aliens and Nationality 1 2012-01-01 2012-01-01 false Temporary Worker Visa Exit Program. 215.9... ALIENS DEPARTING FROM THE UNITED STATES § 215.9 Temporary Worker Visa Exit Program. An alien admitted on certain temporary worker visas at a port of entry participating in the Temporary Worker Visa Exit Program...

  16. 8 CFR 215.9 - Temporary Worker Visa Exit Program.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 8 Aliens and Nationality 1 2014-01-01 2014-01-01 false Temporary Worker Visa Exit Program. 215.9... ALIENS DEPARTING FROM THE UNITED STATES § 215.9 Temporary Worker Visa Exit Program. An alien admitted on certain temporary worker visas at a port of entry participating in the Temporary Worker Visa Exit Program...

  17. Exit Exam as Academic Performance Indicator

    ERIC Educational Resources Information Center

    Al Ahmad, Mahmoud; Al Marzouqi, Ali H.; Hussien, Mousa

    2014-01-01

    This paper focuses on the impact of exit exams on different elements of the educational process, namely: curriculum development, students and instructors. A 50-question multiple-choice Exit Exam was prepared by Electrical Engineering (EE) faculty members covering a poll of questions from EE core courses. A copy of the Exit Exam applied during each…

  18. DESIGN ANALYSIS OF RADIAL INFLOW TURBINES

    NASA Technical Reports Server (NTRS)

    Glassman, A. J.

    1994-01-01

    This program performs a velocity-diagram analysis required for determining geometry and estimating performance for radial-inflow turbines. Input design requirements are power, mass flow rate, inlet temperature and pressure, and rotative rate. The design variables include stator-exit angle, rotor-exit-tip to rotor-inlet radius ratio, rotor-exit-hub to tip radius ratio, and the magnitude and radial distribution of rotor-exit tangential velocity. The program output includes diameters, total and static efficiences, all absolute and relative temperatures, pressures, and velocities, and flow angles at stator inlet, stator exit, rotor inlet, and rotor exit. Losses accounted for in this program by the internal loss model are three-dimensional (profile plus end wall) viscous losses in the stator and the rotor, the disk-friction loss on the back side of the rotor, the loss due to the clearance between the rotor tip and the outer casing, and the exit velocity loss. The flow analysis is one-dimensional at the stator inlet, stator exit, and rotor inlet, each of these calculation stations being at a constant radius. At the rotor exit where there is a variation in flow-field radius, an axisymmetric two-dimensional analysis is made using constant height sectors. Simple radial equilibrium is used to establish the static pressure gradient at the rotor exit. This program is written in FORTRAN V and has been implemented on a UNIVAC 1100 series computer with a memory requirement of approximately 22K of 36 bit words.

  19. Colonization by Legionella spp. of water networks in residential buildings of the Province of Pisa, Italy.

    PubMed

    Baggiani, A; Casini, B; Totaro, M; Aquino, F; Valentini, P; Bruni, B; Porretta, A; Casalini, F; Miccoli, M; Privitera, G

    2015-01-01

    Despite the increase of community acquired cases of legionellosis in Italy over the last years, the Italian guidelines do not give indications for prevention and control of Legionella in the hot water networks (or centralized conditioning systems) of residential buildings. We performed a survey on eight medium sized apartment buildings in the Pisa district to assess the prevalence of Legionella spp. in the water network and the respondance to drinking water requisites at the point of use, according to the Italian norms. For each building two hot water and three cold water samples (located at water entrance from the aqueduct network into the building pipework, at the exit from pressure autoclave, and at a remote tap) were collected. Legionella was detected in 20% of residential buildings, mostly in those with a central hot water production system. The study highlights a condition of potential risk for susceptible population subgroups and supports the need for measures of risk assessment and control.

  20. Occupational and educational inequalities in exit from employment at older ages: evidence from seven prospective cohorts.

    PubMed

    Carr, Ewan; Fleischmann, Maria; Goldberg, Marcel; Kuh, Diana; Murray, Emily T; Stafford, Mai; Stansfeld, Stephen; Vahtera, Jussi; Xue, Baowen; Zaninotto, Paola; Zins, Marie; Head, Jenny

    2018-05-01

    Past studies have identified socioeconomic inequalities in the timing and route of labour market exit at older ages. However, few studies have compared these trends cross-nationally and existing evidence focuses on specific institutional outcomes (such as disability pension and sickness absence) in Nordic countries. We examined differences by education level and occupational grade in the risks of work exit and health-related work exit. Prospective longitudinal data were drawn from seven studies (n=99 164). Participants were in paid work at least once around age 50. Labour market exit was derived based on reductions in working hours, changes in self-reported employment status or from administrative records. Health-related exit was ascertained by receipt of health-related benefit or pension or from the reported reason for stopping work. Cox regression models were estimated for each study, adjusted for baseline self-rated health and birth cohort. There were 50 003 work exits during follow-up, of which an average of 14% (range 2-32%) were health related. Low level education and low occupational grade were associated with increased risks of health-related exit in most studies. Low level education and occupational grade were also associated with an increased risk of any exit from work, although with less consistency across studies. Workers with low socioeconomic position have an increased risk of health-related exit from employment. Policies that extend working life may disadvantage such workers disproportionally, especially where institutional support for those exiting due to poor health is minimal. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Spark gap switch system with condensable dielectric gas

    DOEpatents

    Thayer, III, William J.

    1991-01-01

    A spark gap switch system is disclosed which is capable of operating at a high pulse rate comprising an insulated switch housing having a purging gas entrance port and a gas exit port, a pair of spaced apart electrodes each having one end thereof within the housing and defining a spark gap therebetween, an easily condensable and preferably low molecular weight insulating gas flowing through the switch housing from the housing, a heat exchanger/condenser for condensing the insulating gas after it exits from the housing, a pump for recirculating the condensed insulating gas as a liquid back to the housing, and a heater exchanger/evaporator to vaporize at least a portion of the condensed insulating gas back into a vapor prior to flowing the insulating gas back into the housing.

  2. Steam exit flow design for aft cavities of an airfoil

    DOEpatents

    Storey, James Michael; Tesh, Stephen William

    2002-01-01

    Turbine stator vane segments have inner and outer walls with vanes extending therebetween. The inner and outer walls have impingement plates. Steam flowing into the outer wall passes through the impingement plate for impingement cooling of the outer wall surface. The spent impingement steam flows into cavities of the vane having inserts for impingement cooling the walls of the vane. The steam passes into the inner wall and through the impingement plate for impingement cooling of the inner wall surface and for return through return cavities having inserts for impingement cooling of the vane surfaces. A skirt or flange structure is provided for shielding the steam cooling impingement holes adjacent the inner wall aerofoil fillet region of the nozzle from the steam flow exiting the aft nozzle cavities. Moreover, the gap between the flash rib boss and the cavity insert is controlled to minimize the flow of post impingement cooling media therebetween. This substantially confines outflow to that exiting via the return channels, thus furthermore minimizing flow in the vicinity of the aerofoil fillet region that may adversely affect impingement cooling thereof.

  3. Evaluating sediment capture rates for different sediment basin designs.

    DOT National Transportation Integrated Search

    2007-08-01

    The effectiveness of sediment control devices was studied on a large NC DOT project to determine the : effects of different designs and conditions. Flow and sediment content of water exiting six different traps : and basins were measured and the amou...

  4. 45. Communication equipment room, cable air dryer on left, motorola ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. Communication equipment room, cable air dryer on left, motorola base station (vhf) at right, looking southwest - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  5. Halon Replacement Program for Aviation, Aircraft Engine Nacelle Application Phase II - Operational Comparison of Selected Extinguishants

    DTIC Science & Technology

    1997-05-01

    Control Butterfly Hi-Pressure High Flow Control Butterfly Ejector Primary Clycol Control Valve Scrubber Fan Pressure Control Butterfly 8" Venturi ...the scrubber . 20 ■ SCRUBBER FAN BLOWER INLET VALVE VP-2 VP-3 VP-4 VP-5 VP-6 VP-7 VP-8 VP-9 VP-10 SV-1 SV-2 DESCRIPTION Atmospheric...Blower Bypass Butterfly 24" Venturi Control Butterfly 24" Test Section Exit Butterfly Ejector 10’ Secondary Inlet-Butterfly Hi-pressure Low Flow

  6. Exhaust gas bypass valve control for thermoelectric generator

    DOEpatents

    Reynolds, Michael G; Yang, Jihui; Meisner, Greogry P.; Stabler, Francis R.; De Bock, Hendrik Pieter Jacobus; Anderson, Todd Alan

    2012-09-04

    A method of controlling engine exhaust flow through at least one of an exhaust bypass and a thermoelectric device via a bypass valve is provided. The method includes: determining a mass flow of exhaust exiting an engine; determining a desired exhaust pressure based on the mass flow of exhaust; comparing the desired exhaust pressure to a determined exhaust pressure; and determining a bypass valve control value based on the comparing, wherein the bypass valve control value is used to control the bypass valve.

  7. LabVIEW interface with Tango control system for a multi-technique X-ray spectrometry IAEA beamline end-station at Elettra Sincrotrone Trieste

    NASA Astrophysics Data System (ADS)

    Wrobel, P. M.; Bogovac, M.; Sghaier, H.; Leani, J. J.; Migliori, A.; Padilla-Alvarez, R.; Czyzycki, M.; Osan, J.; Kaiser, R. B.; Karydas, A. G.

    2016-10-01

    A new synchrotron beamline end-station for multipurpose X-ray spectrometry applications has been recently commissioned and it is currently accessible by end-users at the XRF beamline of Elettra Sincrotrone Trieste. The end-station consists of an ultra-high vacuum chamber that includes as main instrument a seven-axis motorized manipulator for sample and detectors positioning, different kinds of X-ray detectors and optical cameras. The beamline end-station allows performing measurements in different X-ray spectrometry techniques such as Microscopic X-Ray Fluorescence analysis (μXRF), Total Reflection X-Ray Fluorescence analysis (TXRF), Grazing Incidence/Exit X-Ray Fluorescence analysis (GI-XRF/GE-XRF), X-Ray Reflectometry (XRR), and X-Ray Absorption Spectroscopy (XAS). A LabVIEW Graphical User Interface (GUI) bound with Tango control system consisted of many custom made software modules is utilized as a user-friendly tool for control of the entire end-station hardware components. The present work describes this advanced Tango and LabVIEW software platform that utilizes in an optimal synergistic manner the merits and functionality of these well-established programming and equipment control tools.

  8. Relationship between cattle temperament as determined by exit velocity carcass merit in beef cattle

    USDA-ARS?s Scientific Manuscript database

    The objective of this trial was to use cattle temperament, as determined by exit velocity only, as a means to evaluate the impact of temperament on carcass merit and the possible utilization of exit velocity alone as a sorting tool within the feedlot. At the time of processing, exit velocity and bod...

  9. Exit Strategies: How Low-Performing High Schools Respond to High School Exit Examination Requirements

    ERIC Educational Resources Information Center

    Holme, Jennifer Jellison

    2013-01-01

    Background: Over the past several decades, a significant number of states have either adopted or increased high school exit examination requirements. Although these policies are intended to generate improvement in schools, little is known about how high schools are responding to exit testing pressures. Purpose: This study examined how five…

  10. 24 CFR 3280.106 - Exit facilities; egress windows and devices.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Exit facilities; egress windows and... § 3280.106 Exit facilities; egress windows and devices. (a) Every room designed expressly for sleeping purposes, unless it has an exit door (see § 3280.105), shall have at least one outside window or approved...

  11. Exit Exams: Decreases or Increases the Dropout Rate

    ERIC Educational Resources Information Center

    Barnes, Teresa A.

    2009-01-01

    The purpose of this paper was to examine the impact of exit exams on the dropout rate. Data was gathered from several research articles. The most impressionable research revealed exit exams have a negative effect on minorities, especially black males. Results indicate by 2012, that exit exams in 25 states will affect 81 percent of minority high…

  12. Rotor with Flattened Exit Pressure Profile

    NASA Technical Reports Server (NTRS)

    Baltas, Constantine (Inventor); Prasad, Dilip (Inventor); Gallagher, Edward J. (Inventor)

    2015-01-01

    A rotor blade comprises an airfoil extending radially from a root section to a tip section and axially from a leading edge to a trailing edge, the leading and trailing edges defining a curvature therebetween. The curvature determines a relative exit angle at a relative span height between the root section and the tip section, based on an incident flow velocity at the leading edge of the airfoil and a rotational velocity at the relative span height. In operation of the rotor blade, the relative exit angle determines a substantially flat exit pressure ratio profile for relative span heights from 75% to 95%, wherein the exit pressure ratio profile is constant within a tolerance of 10% of a maximum value of the exit pressure ratio profile.

  13. Evaluation of the Performance and Flow in an Axial Compressor.

    DTIC Science & Technology

    1982-10-01

    A Exit Rake P 11.00-P tP noz P2noz -PA SP-1 PHub - PA Exit Rake Pt11.50-Pt p - PA SP-1 PTip - PA Exit Rake Pt2.00-PPtpipe ATp Att Pspipe - PA SP-2...PTip - PA Exit Rake Pt6.50-Pt Inlet Rake Pt14.40-PA SP-8 PTip - PA Exit Rake Pt 17.00-Pt Inlet Rake Pt 1.30-PA SP-8 PHub - PA Exit Rake Pt17.50-Pt...Determination from Probe Pressures Pt (1) =((Pt=(1) + Phub ) + (Pt(1) + Pt(2)))/3 P t(2) P t(2) Pt (3) = t(3) P t(4) = (P t(3) + P t(4))/2 P t(5) =P t(4) Pt

  14. Mean-field theory for pedestrian outflow through an exit.

    PubMed

    Yanagisawa, Daichi; Nishinari, Katsuhiro

    2007-12-01

    The average pedestrian flow through an exit is one of the most important indices in evaluating pedestrian dynamics. In order to study the flow in detail, the floor field model, which is a crowd model using cellular automata, is extended by taking into account realistic behavior of pedestrians around the exit. The model is studied by both numerical simulations and cluster analysis to obtain a theoretical expression for the average pedestrian flow through the exit. It is found quantitatively that the effects of exit door width, the wall, and the pedestrian mood of competition or cooperation significantly influence the average flow. The results show that there is a suitable width and position of the exit according to the pedestrians' mood.

  15. Biopesticides

    MedlinePlus

    ... and registration of biopesticides for use in pest management systems for specialty crops or for minor uses on major crops. Find out more about the IR-4 Project activities, workshops, and research grants . Exit National Product ...

  16. Emissions-critical charge cooling using an organic rankine cycle

    DOEpatents

    Ernst, Timothy C.; Nelson, Christopher R.

    2014-07-15

    The disclosure provides a system including a Rankine power cycle cooling subsystem providing emissions-critical charge cooling of an input charge flow. The system includes a boiler fluidly coupled to the input charge flow, an energy conversion device fluidly coupled to the boiler, a condenser fluidly coupled to the energy conversion device, a pump fluidly coupled to the condenser and the boiler, an adjuster that adjusts at least one parameter of the Rankine power cycle subsystem to change a temperature of the input charge exiting the boiler, and a sensor adapted to sense a temperature characteristic of the vaporized input charge. The system includes a controller that can determine a target temperature of the input charge sufficient to meet or exceed predetermined target emissions and cause the adjuster to adjust at least one parameter of the Rankine power cycle to achieve the predetermined target emissions.

  17. System concept for a moderate cost Large Deployable Reflector (LDR)

    NASA Technical Reports Server (NTRS)

    Swanson, P. N.; Breckinridge, J. B.; Diner, A.; Freeland, R. E.; Irace, W. R.; Mcelroy, P. M.; Meinel, A. B.; Tolivar, A. F.

    1986-01-01

    A study was carried out at JPL during the first quarter of 1985 to develop a system concept for NASA's LDR. Major features of the concept are a four-mirror, two-stage optical system; a lightweight structural composite segmented primary reflector; and a deployable truss backup structure with integral thermal shield. The two-stage optics uses active figure control at the quaternary reflector located at the primary reflector exit pupil, allowing the large primary to be passive. The lightweight composite reflector panels limit the short-wavelength operation to approximately 30 microns but reduce the total primary reflector weight by a factor of 3 to 4 over competing technologies. On-orbit thermal analysis indicates a primary reflector equilibrium temperature of less than 200 K with a maximum gradient of about 5 C across the 20-m aperture. Weight and volume estimates are consistent with a single Shuttle launch, and are based on Space Station assembly and checkout.

  18. Microgravity Storage Vessels and Conveying-Line Feeders for Cohesive Regolith

    NASA Technical Reports Server (NTRS)

    Walton, Otis R.; Vollmer, Hubert J.

    2013-01-01

    Under microgravity, the usual methods of placing granular solids into, or extracting them from, containers or storage vessels will not function. Alternative methods are required to provide a motive force to move the material. New configurations for microgravity regolith storage vessels that do not resemble terrestrial silos, hoppers, or tanks are proposed. The microgravity-compatible bulk-material storage vessels and exit feed configurations are designed to reliably empty and feed cohesive material to transfer vessels or conveying ducts or lines without gravity. A controllable motive force drives the cohesive material to the exit opening(s), and provides a reliable means to empty storage vessels and/or to feed microgravity conveying lines. The proposed designs will function equally well in vacuum, or inside of pressurized enclosures. Typical terrestrial granular solids handling and storage equipment will not function under microgravity, since almost all such equipment relies on gravity to at least move material to an exit location or to place it in the bottom of a container. Under microgravity, there effectively are no directions of up or down, and in order to effect movement of material, some other motive force must be applied to the material. The proposed storage vessels utilize dynamic centrifugal force to effect movement of regolith whenever material needs to be removed from the storage vessel. During simple storage, no dynamic motion or forces are required. The rotation rate during emptying can be controlled to ensure that material will move to the desired exit opening, even if the material is highly cohesive, or has acquired an electrostatic charge. The general concept of this Swirl Action Utilized for Centrifugal Ejection of Regolith (SAUCER) microgravity storage unit/dynamic feeder is to have an effective slot-hopper (based on the converging angles of the top and bottom conical section of the vessel) with an exit slot around the entire periphery of the SAUCER. The basic shape of such a unit is like two Chinese straw hats (douli) - one upside down, on the bottom, and another on top; or two wokpans, one upright on the bottom and another inverted on top, with a small gap between the upright and inverted pans or hats (around the periphery). A stationary outer ring, much like an unmounted bicycle tire, surrounds the gap between the two coaxial, nearly conical pieces, forming the top and bottom of the unit.

  19. Scaling laws in granular flow and pedestrian flow

    NASA Astrophysics Data System (ADS)

    Chen, Shumiao; Alonso-Marroquin, Fernando; Busch, Jonathan; Hidalgo, Raúl Cruz; Sathianandan, Charmila; Ramírez-Gómez, Álvaro; Mora, Peter

    2013-06-01

    We use particle-based simulations to examine the flow of particles through an exit. Simulations involve both gravity-driven particles (representing granular material) and velocity-driven particles (mimicking pedestrian dynamics). Contact forces between particles include elastic, viscous, and frictional forces; and simulations use bunker geometry. Power laws are observed in the relation between flow rate and exit width. Simulations of granular flow showed that the power law has little dependence on the coefficient of friction. Polydisperse granular systems produced higher flow rates than those produced by monodisperse ones. We extend the particle model to include the main features of pedestrian dynamics: thoracic shape, shoulder rotation, and desired velocity oriented towards the exit. Higher desired velocity resulted in higher flow rate. Granular simulations always give higher flow rate than pedestrian simulations, despite the values of aspect ratio of the particles. In terms of force distribution, pedestrians and granulates share similar properties with the non-democratic distribution of forces that poses high risks of injuries in a bottleneck situation.

  20. Method for producing ceramic particles and agglomerates

    DOEpatents

    Phillips, Jonathan; Gleiman, Seth S.; Chen, Chun-Ku

    2001-01-01

    A method for generating spherical and irregularly shaped dense particles of ceramic oxides having a controlled particle size and particle size distribution. An aerosol containing precursor particles of oxide ceramics is directed into a plasma. As the particles flow through the hot zone of the plasma, they melt, collide, and join to form larger particles. If these larger particles remain in the hot zone, they continue melting and acquire a spherical shape that is retained after they exit the hot zone, cool down, and solidify. If they exit the hot zone before melting completely, their irregular shape persists and agglomerates are produced. The size and size distribution of the dense product particles can be controlled by adjusting several parameters, the most important in the case of powder precursors appears to be the density of powder in the aerosol stream that enters the plasma hot zone. This suggests that particle collision rate is responsible for determining ultimate size of the resulting sphere or agglomerate. Other parameters, particularly the gas flow rates and the microwave power, are also adjusted to control the particle size distribution.

Top