Detection techniques for tenuous planetary atmospheres
NASA Technical Reports Server (NTRS)
Hoenig, S. A.
1972-01-01
The research for the development of new types of detectors for analysis of planetary atmospheres is summarized. Topics discussed include: corona discharge humidity detector, surface catalysis and exo-electron emission, and analysis of soil samples by means of exo-electron emission. A report on the exo-electron emission during heterogeneous catalysis is included.
Exoelectronic emission of particles of lunar surface material
NASA Technical Reports Server (NTRS)
Mints, R. I.; Alimov, V. I.; Melekhin, V. P.; Milman, I. I.; Kryuk, V. I.; Kunin, L. L.; Tarasov, L. S.
1974-01-01
A secondary electron multiplier was used to study the thermostimulated exoelectronic emission of particles of lunar surface material returned by the Soviet Luna 16 automatic station. The natural exoemission from fragments of slag, glass, anorthosite, and a metallic particle was recorded in the isochronic and isothermal thermostimulation regimes. The temperature of emission onset depended on the type of regolith fragment. For the first three particles the isothermal drop in emission is described by first-order kinetic equations. For the anorthosite fragment, exoemission at constant temperature is characterized by a symmetric curve with a maximum. These data indicate the presence of active surface defects, whose nature can be due to the prehistory of the particles.
Apparatus for measurements of thermal and optical stimulated exo-electron emission and luminescence
NASA Astrophysics Data System (ADS)
Pokorný, P.; Novotný, M.; Fitl, P.; Zuklín, J.; Vlček, J.; Nikl, J.; Marešová, E.; Hruška, P.; Bulíř, J.; Drahokoupil, J.; Čerňanský, M.; Lančok, J.
2018-06-01
The purpose of the design, construction and implementation of vacuum apparatus for measuring simultaneously three or more stimulated phenomena in dielectrics and eventually semiconductors is to investigate those phenomena as a function of temperature and wavelength. The test of equipment and its functionality were carried out step by step (apparatus, components and control sample) and associated with the calculation of the main physical parameters. The tests of individual parts of the apparatus clearly confirmed that the design, construction and selected components fulfil or even exceed the required properties. On the basis of the measurement of selected sample, it was shown that even weak signals from the material can be detected from both thermally stimulated luminescence and thermally stimulated exo-electron emission moreover transmission and desorption can be measured. NaCl:Ni (0.2%) was chosen as the test material. The activation energies and frequency factor were calculated using the methods of different authors.
Exoelectron emission from a clean, annealed magnesium single crystal during oxygen adsorption
NASA Technical Reports Server (NTRS)
Ferrante, J.
1976-01-01
Exoelectron emission was observed from a clean, annealed Mg (0001) surface during oxygen and chlorine adsorption at pressures of 6.5x10 0.00001- N/sq m and lower. the studies were performed in an ultrahigh vacuum system. The crystals were cleaned by argon ion bombardment and annealed at 300 C. Auger electron spectroscopy was used to verify surface cleanliness, and low energy electron diffraction was used to verify that the surface was annealed. The emission was found to be oxygen arrival rate dependent. Two peaks were observed in the electron emission with exposure. Evidence is presented that the formation of the second peak corresponds to oxidation of the Mg surface. No emission was observed from clean aluminum during adsorption. Results verify that electron emission occurs from a strain free surface simply upon adsorption of oxygen. A qualitative explanation for the mechanisms of emission in terms of chemical effects is presented.
Detection techniques for tenuous planetary atmospheres
NASA Technical Reports Server (NTRS)
Hoenig, S. A.; Bebee, E. M.; Kumiega, E. M.; Savitz, C. W.; Stolle, E.; Summerton, J. E.
1973-01-01
The research performed during this period is reported. The studies discussed include: dust grinding and electrification, effects of metallic impurities on exoelectron emission, the connection between the charge acquired by the dust and the effect of the dust on human lung tissue. A list of publications generated by this research is included.
Detection of oxygen-related defects in GaAs by exo-electron emission spectroscopy
NASA Astrophysics Data System (ADS)
Hulluvarad, Shiva S.; Naddaf, M.; Bhoraskar, S. V.
2001-10-01
The influence of intentional introduction of oxygen, at the surface of GaAs, on its native surface states was studied. Oxygen was made to interact with the surface of GaAs by three different means: (1) by growing native oxides, (2) exposing to oxygen plasma in an electron cyclotron resonance (ECR) plasma reactor and by (3) high energy oxygen ion irradiation. Thermally stimulated exo-electron emission (TSEE) spectroscopy was used to estimate the relative densities and energies of the surface states induced by the three different modes of introducing oxygen. Out of the two native defect levels found in GaAs by TSEE; at 325 K (0.7 eV below Ec) and at 415 K (0.9 below Ec); the former is seen to get broadened or split into multiple peaks in each of the methods. Multiple peaks in TSEE signify the presence of a closely spaced band of defect levels. Therefore the results exclusively point out that oxygen-related complexes contribute to the formation of a band of defects centered at 325 K in TSEE which is correlated to an energy level 0.7 eV below Ec known as the EL2 defect level. The results reported in this paper thus confirm that the TSEE peak at 0.7 eV below Ec is related to oxygen induced defects whereas the peak at 0.9 eV is not affected by the presence of oxygen-related species.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krix, David; Nienhaus, Hermann, E-mail: hermann.nienhaus@uni-due.de
2014-08-21
Thin potassium films grown on Si(001) substrates are used to measure internal chemicurrents and the external emission of exoelectrons simultaneously during adsorption of molecular oxygen on K surfaces at 120 K. The experiments clarify the dynamics of electronic excitations at a simple metal with a narrow valence band. X-ray photoemission reveals that for exposures below 5 L almost exclusively peroxide K{sub 2}O{sub 2} is formed, i.e., no dissociation of the molecule occurs during interaction. Still a significant chemicurrent and a delayed exoelectron emission are detected due to a rapid injection of unoccupied molecular levels below the Fermi level. Since themore » valence band width of potassium is approximately equal to the potassium work function (2.4 eV) the underlying mechanism of exoemission is an Auger relaxation whereas chemicurrents are detected after resonant charge transfer from the metal valence band into the injected level. The change of the chemicurrent and exoemission efficiencies with oxygen coverage can be deduced from the kinetics of the reaction and the recorded internal and external emission currents traces. It is shown that the non-adiabaticity of the reaction increases with coverage due to a reduction of the electronic density of states at the surface while the work function does not vary significantly. Therefore, the peroxide formation is one of the first reaction systems which exhibits varying non-adiabaticity and efficiencies during the reaction. Non-adiabatic calculations based on model Hamiltonians and density functional theory support the picture of chemicurrent generation and explain the rapid injection of hot hole states by an intramolecular motion, i.e., the expansion of the oxygen molecule on the timescale of a quarter of a vibrational period.« less
Summary of nondestructive testing theory and practice
NASA Technical Reports Server (NTRS)
Meister, R. P.; Randall, M. D.; Mitchell, D. K.; Williams, L. P.; Pattee, H. E.
1972-01-01
The ability to fabricate design critical and man-rated aerospace structures using materials near the limits of their capabilities requires a comprehensive and dependable assurance program. The quality assurance program must rely heavily on nondestructive testing methods for thorough inspection to assess properties and quality of hardware items. A survey of nondestructive testing methods is presented to provide space program managers, supervisors and engineers who are unfamiliar with this technical area with appropriate insight into the commonly accepted nondestructive testing methods available, their interrelationships, used, advantages and limitations. Primary emphasis is placed on the most common methods: liquid penetrant, magnetic particle, radiography, ultrasonics and eddy current. A number of the newer test techniques including thermal, acoustic emission, holography, microwaves, eddy-sonic and exo-electron emission, which are beginning to be used in applications of interest to NASA, are also discussed briefly.
Surface plasmon coupled chemiluminescence during adsorption of oxygen on magnesium surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagemann, Ulrich; Nienhaus, Hermann, E-mail: hermann.nienhaus@uni-due.de
The dissociative adsorption of oxygen molecules on magnesium surfaces represents a non-adiabatic reaction exhibiting exoelectron emission, chemicurrent generation, and weak chemiluminescence. Using thin film Mg/Ag/p-Si(111) Schottky diodes with 1 nm Mg on a 10-60 nm thick Ag layer as 2π-photodetectors, the chemiluminescence is internally detected with a much larger efficiency than external methods. The chemically induced photoyield shows a maximum for a Ag film thickness of 45 nm. The enhancement is explained by surface plasmon coupled chemiluminescence, i.e., surface plasmon polaritons are effectively excited in the Ag layer by the oxidation reaction and decay radiatively leading to the observed photocurrent.more » Model calculations of the maximum absorption in attenuated total reflection geometry support the interpretation. The study demonstrates the extreme sensitivity and the practical usage of internal detection schemes for investigating surface chemiluminescence.« less
NASA Astrophysics Data System (ADS)
Hellberg, Lars; Kasemo, Bengt
Some strongly exothermic and non-adiabatic surface adsorption events, especially those where electronegative molecules adsorb on very electropositive (low work function) surfaces, are accompanied by emission of (exo)electrons, photons, excited atoms and negative ions. The reaction of halogen molecules with halogen surfaces constitute an efficient model system for such studies. We have previously reported data for the emission of negative particles and photons in the zero coverage limit for a range of velocities of Cl2 molecules impinging on cold potassium surfaces as well as the mechanism behind these emission processes. In the present work, we focus on measurements of the kinetics, i.e. the exposure/coverage dependence, of these processes for the same system. Specifically, we present data for, (i) the separated contributions from electrons and Cl- ions of the emitted negative particles, (ii) the photon emission stemming both from excited Potassium atoms and from the equivalent process causing electron emission, (iii) the change of the work function during the initial exposure and, finally, (iv) the sticking coefficient for different Cl2 velocities and exposures.