Sample records for expanded metal screen

  1. THE USEPA'S METAL FINISHING FACILITY RISK SCREENING TOOL (MFFRST) AND POLLUTION PREVENTION TOOL (MFFP2T)

    EPA Science Inventory

    This presentation will provide an overview of the USEPA's Metal Finishing Facility Risk Screening Tool, including a discussion of the models used and outputs. The tool is currently being expanded to include pollution prevention considerations as part of the model. The current st...

  2. Fluorescent and Lanthanide Labeling for Ligand Screens, Assays, and Imaging

    PubMed Central

    Josan, Jatinder S.; De Silva, Channa R.; Yoo, Byunghee; Lynch, Ronald M.; Pagel, Mark D.; Vagner, Josef; Hruby, Victor J.

    2012-01-01

    The use of fluorescent (or luminescent) and metal contrast agents in high-throughput screens, in vitro assays, and molecular imaging procedures has rapidly expanded in recent years. Here we describe the development and utility of high-affinity ligands for cancer theranostics and other in vitro screening studies. In this context, we also illustrate the syntheses and use of heteromultivalent ligands as targeted imaging agents. PMID:21318902

  3. Combination nickel foam expanded nickel screen electrical connection supports for solid oxide fuel cells

    DOEpatents

    Draper, Robert; Prevish, Thomas; Bronson, Angela; George, Raymond A.

    2007-01-02

    A solid oxide fuel assembly is made, wherein rows (14, 25) of fuel cells (17, 19, 21, 27, 29, 31), each having an outer interconnection (20) and an outer electrode (32), are disposed next to each other with corrugated, electrically conducting expanded metal mesh member (22) between each row of cells, the corrugated mesh (22) having top crown portions and bottom portions, where the top crown portion (40) have a top bonded open cell nickel foam (51) which contacts outer interconnections (20) of the fuel cells, said mesh and nickel foam electrically connecting each row of fuel cells, and where there are no more metal felt connections between any fuel cells.

  4. Expanded nickel screen electrical connection supports for solid oxide fuel cells

    DOEpatents

    Draper, Robert; Antol, Ronald F.; Zafred, Paolo R.

    2002-01-01

    A solid oxide fuel assembly is made, wherein rows (14, 24) of fuel cells (16, 18, 20, 26, 28, 30), each having an outer interconnection (36) and an outer electrode (32), are disposed next to each other with corrugated, electrically conducting expanded metal mesh (22) between each row of cells, the corrugated mesh (22) having top crown portions (40) and bottom shoulder portions (42), where the top crown portion (40) contacts outer interconnections (36) of the fuel cells (16, 18, 20) in a first row (14), and the bottom shoulder portions (42) contacts outer electrodes (32) of the fuel cells in a second row (24), said mesh electrically connecting each row of fuel cells, and where there are no metal felt connections between any fuel cells.

  5. An update of the JPL program to develop Li-SOCl2 cells

    NASA Technical Reports Server (NTRS)

    Halpert, S.; Ang, V.; Banes, R.; Dawson, S.; Frank, H.; Subbarao, S.; Whitcanack, L.

    1985-01-01

    The goal of producing spiral wound D cell was met. The cell design and electrodes, particularly the carbon cathodes were produced in-house. Also all parts were assembled, the welding performed, the electrolyte aided and the cells sealed in-house. The lithium capacity (theoretical) was 19.3 Ah and that of the SOCl2 in the 1.8 m LiAlCl4 electrolyte, 16.4 Ah (a greater excess of SOCl2 is necessary for safe high rate operation). The electrode surface area was 452 sq cm. The carbon electrode comprised Shawinigen Black/Teflon -30 (90/10 by weight) mixture 0.020 inches thick on an expanded metal screen prepared in the JPL laboratory. There were two tab connections to the cathode. The 0.0078 inch thick lithium foil was rolled into an expanded nickel screen. The separator was Mead 934-5 fiberglass material.

  6. Optimization of a hydrodynamic separator using a multiscale computational fluid dynamics approach.

    PubMed

    Schmitt, Vivien; Dufresne, Matthieu; Vazquez, Jose; Fischer, Martin; Morin, Antoine

    2013-01-01

    This article deals with the optimization of a hydrodynamic separator working on the tangential separation mechanism along a screen. The aim of this study is to optimize the shape of the device to avoid clogging. A multiscale approach is used. This methodology combines measurements and computational fluid dynamics (CFD). A local model enables us to observe the different phenomena occurring at the orifice scale, which shows the potential of expanded metal screens. A global model is used to simulate the flow within the device using a conceptual model of the screen (porous wall). After validation against the experimental measurements, the global model was used to investigate the influence of deflectors and disk plates in the structure.

  7. Cobalt Chrome Spinal Constructs Trigger Airport Security Screening in 24% of Pediatric Patients.

    PubMed

    Woon, Regina P; Andras, Lindsay M; Barrett, Kody K; Skaggs, David L

    2015-03-01

    Retrospective study. To determine whether pediatric patients undergo additional airport security screening after posterior spinal fusion. Airport security has expanded to include body scanners as well as traditional metal detectors. Families frequently ask whether spinal implants will trigger airport security, but there is limited information on modern implants and screening methods. The researchers conducted a survey of 50 pediatric patients after posterior spinal fusion from 2004 to 2013. Inclusion criteria were posterior instrumentation, pedicle screws for at least 80% of anchors, and at least 1 trip through an American airport after surgery. Charts and radiographs were reviewed for metal type, number of levels fused, number of anchors, and rod diameter. A total of 16% of patients (8 of 50) were detected by body scan or metal detector and all had cobalt chrome (CoCr) rods. No patients with stainless-steel (SS) rods were detected. The CoCr rods triggered additional screening in 24% of children (8 of 33), compared with none of 17 with SS rods (p = .03). For patients with CoCr rods, the detection rate was 18% (5 of 28) by metal detector and 17% (3 of 18) by body scanner. For patients with CoCr rods, there was no significant difference between detection rates and levels fused (p = .30), number of anchors (p = .15), or rod diameter (p = .17). In this series, CoCr constructs were more likely to incur additional airport security compared with more traditional SS constructs. Copyright © 2015 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  8. Miniature and Molecularly Specific Optical Screening Technologies for Breast Cancer

    DTIC Science & Technology

    2011-10-01

    generated by the photodiode. When we expanded to a 4x4 probe for imaging, we used a multi-channel transimpedance amplifier (Multiboard, SolGel Technologies...GmbH) so that the signals can be read simultaneously. The transimpedance amplifier circuitry was assembled within a small metal housing and powered...600 nm) greater than 2/cm. We started designing a new integrateded transimpedance amplifier (ITIA) array, which will also have multplexed ADC

  9. Dosimetry around metallic ports in tissue expanders in patients receiving postmastectomy radiation therapy: an ex vivo evaluation.

    PubMed

    Moni, Janaki; Graves-Ditman, Maria; Cederna, Paul; Griffith, Kent; Krueger, Editha A; Fraass, Benedick A; Pierce, Lori J

    2004-01-01

    Postmastectomy breast reconstruction can be accomplished utilizing tissue expanders and implants. However, in patients who require postoperative radiotherapy, the complication rate with tissue expander/implant reconstruction can exceed 50%. One potential cause of this high complication rate may be the metallic port in the tissue expander producing altered dosimetry in the region of the metallic device. The purpose of this study was to quantify the radiation dose distribution in the vicinity of the metallic port and determine its potential contribution to this extremely high complication rate. The absolute dosimetric effect of the tissue expander's metallic port was quantified using film and thermoluminescent dosimetry (TLD) studies with a single beam incident on a metallic port extracted from an expander. TLD measurements were performed at 11 reproducible positions on an intact expander irradiated with tangential fields. A computed tomography (CT)-based treatment plan without inhomogeneity corrections was used to derive expected doses for all TLD positions. Multiple irradiation experiments were performed for all TLD data. Confidence intervals for the dose at TLD sites with the metallic port in place were compared to the expected dose at the site without the metallic port. Film studies did not reveal a significant component of scatter around the metallic port. TLD studies of the extracted metallic port revealed highest doses within the casing of the metallic port and no consistent increased dose at the surface of the expander. No excess dose due to the metallic port in the expander was noted with the phantom TLD data. Based upon these results, it does not appear that the metallic port in tissue expanders significantly contributes to the high complication rate experienced in patients undergoing tissue expander breast reconstruction and receiving radiation therapy. Strategies designed to reduce the breast reconstruction complication rate in this clinical setting will need to focus on factors other than adjusting the dosimetry around the tissue expander metallic port.

  10. Outcomes of an International Workshop on Preconception Expanded Carrier Screening: Some Considerations for Governments.

    PubMed

    Molster, Caron M; Lister, Karla; Metternick-Jones, Selina; Baynam, Gareth; Clarke, Angus John; Straub, Volker; Dawkins, Hugh J S; Laing, Nigel

    2017-01-01

    Consideration of expanded carrier screening has become an emerging issue for governments. However, traditional criteria for decision-making regarding screening programs do not incorporate all the issues relevant to expanded carrier screening. Further, there is a lack of consistent guidance in the literature regarding the development of appropriate criteria for government assessment of expanded carrier screening. Given this, a workshop was held to identify key public policy issues related to preconception expanded carrier screening, which governments should consider when deciding whether to publicly fund such programs. In June 2015, a satellite workshop was held at the European Society of Human Genetics Conference. It was structured around two design features: (1) the provision of information from a range of perspectives and (2) small group deliberations on the key issues that governments need to consider and the benefits, risks, and challenges of implementing publicly funded whole-population preconception carrier screening. Forty-one international experts attended the workshop. The deliberations centered primarily on the conditions to be tested and the elements of the screening program itself. Participants expected only severe conditions to be screened but were concerned about the lack of a consensus definition of "severe." Issues raised regarding the screening program included the purpose, benefits, harms, target population, program acceptability, components of a program, and economic evaluation. Participants also made arguments for consideration of the accuracy of screening tests. A wide range of issues require careful consideration by governments that want to assess expanded carrier screening. Traditional criteria for government decision-making regarding screening programs are not a "best fit" for expanded carrier screening and new models of decision-making with appropriate criteria are required. There is a need to define what a "severe" condition is, to build evidence regarding the reliability and accuracy of screening tests, to consider the equitable availability and downstream effects on and costs of follow-up interventions for those identified as carriers, and to explore the ways in which the components of a screening program would be impacted by unique features of expanded carrier screening.

  11. Development of a web-based tool for automated processing and cataloging of a unique combinatorial drug screen.

    PubMed

    Dalecki, Alex G; Wolschendorf, Frank

    2016-07-01

    Facing totally resistant bacteria, traditional drug discovery efforts have proven to be of limited use in replenishing our depleted arsenal of therapeutic antibiotics. Recently, the natural anti-bacterial properties of metal ions in synergy with metal-coordinating ligands have shown potential for generating new molecule candidates with potential therapeutic downstream applications. We recently developed a novel combinatorial screening approach to identify compounds with copper-dependent anti-bacterial properties. Through a parallel screening technique, the assay distinguishes between copper-dependent and independent activities against Mycobacterium tuberculosis with hits being defined as compounds with copper-dependent activities. These activities must then be linked to a compound master list to process and analyze the data and to identify the hit molecules, a labor intensive and mistake-prone analysis. Here, we describe a software program built to automate this analysis in order to streamline our workflow significantly. We conducted a small, 1440 compound screen against M. tuberculosis and used it as an example framework to build and optimize the software. Though specifically adapted to our own needs, it can be readily expanded for any small- to medium-throughput screening effort, parallel or conventional. Further, by virtue of the underlying Linux server, it can be easily adapted for chemoinformatic analysis of screens through packages such as OpenBabel. Overall, this setup represents an easy-to-use solution for streamlining processing and analysis of biological screening data, as well as offering a scaffold for ready functionality expansion. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Responsible implementation of expanded carrier screening

    PubMed Central

    Henneman, Lidewij; Borry, Pascal; Chokoshvili, Davit; Cornel, Martina C; van El, Carla G; Forzano, Francesca; Hall, Alison; Howard, Heidi C; Janssens, Sandra; Kayserili, Hülya; Lakeman, Phillis; Lucassen, Anneke; Metcalfe, Sylvia A; Vidmar, Lovro; de Wert, Guido; Dondorp, Wybo J; Peterlin, Borut

    2016-01-01

    This document of the European Society of Human Genetics contains recommendations regarding responsible implementation of expanded carrier screening. Carrier screening is defined here as the detection of carrier status of recessive diseases in couples or persons who do not have an a priori increased risk of being a carrier based on their or their partners' personal or family history. Expanded carrier screening offers carrier screening for multiple autosomal and X-linked recessive disorders, facilitated by new genetic testing technologies, and allows testing of individuals regardless of ancestry or geographic origin. Carrier screening aims to identify couples who have an increased risk of having an affected child in order to facilitate informed reproductive decision making. In previous decades, carrier screening was typically performed for one or few relatively common recessive disorders associated with significant morbidity, reduced life-expectancy and often because of a considerable higher carrier frequency in a specific population for certain diseases. New genetic testing technologies enable the expansion of screening to multiple conditions, genes or sequence variants. Expanded carrier screening panels that have been introduced to date have been advertised and offered to health care professionals and the public on a commercial basis. This document discusses the challenges that expanded carrier screening might pose in the context of the lessons learnt from decades of population-based carrier screening and in the context of existing screening criteria. It aims to contribute to the public and professional discussion and to arrive at better clinical and laboratory practice guidelines. PMID:26980105

  13. Role of laser photoablative therapy and expandable metal stents in colorectal carcinoma

    NASA Astrophysics Data System (ADS)

    Chennupati, Raja S.; Trowers, Eugene A.

    2000-05-01

    Metallic stents are effective in relieving colorectal obstruction in more than 80% of cases. Self expanding metallic stents allow for decompression of the proximal colon and preoperative bowel cleansing. Hence, emergent surgery for large bowel obstruction with its associated high morbidity and mortality might be avoided. Endoscopic laser photoablation and stent placement may successfully palliate inoperable colorectal cancer patients by maintaining luminal patency and avoiding the need for a colostomy. Major complications associated with metallic stents include pressure necrosis, perforation, bleeding and migration. The effectiveness of expandable metallic stents in obstructive colorectal carcinoma is critically reviewed. The authors present a concise review of the effectiveness of endoscopic laser photoablation and expandable metal stent placement.

  14. Improvement of quality of life and survival using self-expandable metal stent placement for severe malignant stenosis of the gastric body: a case report.

    PubMed

    Kumagai, Hozumi; Nio, Kenta; Shirakawa, Tsuyoshi; Uchino, Keita; Kusaba, Hitoshi; Isobe, Taichi; Komoda, Masato; Tamura, Shingo; Maeyama, Ryo; Nagai, Eishi; Akashi, Koichi; Baba, Eishi

    2012-09-19

    Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient's general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.

  15. Tubular hydrogen permeable metal foil membrane and method of fabrication

    DOEpatents

    Paglieri, Stephen N.; Birdsell, Stephen A.; Barbero, Robert S.; Snow, Ronny C.; Smith, Frank M.

    2006-04-04

    A tubular hydrogen permeable metal membrane and fabrication process comprises obtaining a metal alloy foil having two surfaces, coating the surfaces with a metal or metal alloy catalytic layer to produce a hydrogen permeable metal membrane, sizing the membrane into a sheet with two long edges, wrapping the membrane around an elongated expandable rod with the two long edges aligned and overlapping to facilitate welding of the two together, placing the foil wrapped rod into a surrounding fixture housing with the two aligned and overlapping foil edges accessible through an elongated aperture in the surrounding fixture housing, expanding the elongated expandable rod within the surrounding fixture housing to tighten the foil about the expanded rod, welding the two long overlapping foil edges to one another generating a tubular membrane, and removing the tubular membrane from within the surrounding fixture housing and the expandable rod from with the tubular membrane.

  16. Comparison of covered and uncovered self-expandable stents in the treatment of malignant biliary obstruction.

    PubMed

    Flores Carmona, Diana Yamel; Alonso Lárraga, Juan Octavio; Hernández Guerrero, Angélica; Ramírez Solís, Mauro Eduardo

    2016-05-01

    Drainage with metallic stents is the treatment of choice in malignant obstructive jaundice. Technical and clinical success with metallic stents is obtained in over 90% and 80% of cases, respectively. There are self-expandable metallic stents designed to increase permeability. The aim of this study was to describe the results obtained with totally covered self-expandable and uncovered self-expandable metallic stents in the palliative treatment of malignant biliary obstruction. Sixty eight patients with malignant obstructive jaundice secondary to pancreatobiliary or metastatic disease not amenable to surgery were retrospectively included. Two groups were created: group A (covered self-expandable metallic stents) (n = 22) and group B (uncovered self-expandable metallic stents) (n = 46). Serum total bilirubin, direct bilirubin, alkaline phosphatase and gamma glutamyl transferase levels decreased in both groups and no statistically significant difference was detected (p = 0.800, p = 0.190, p = 0.743, p = 0.521). Migration was greater with covered stents but it was not statistically significant either (p = 0.101). Obstruction was greater in the group with uncovered stents but it was not statistically significant either (p = 0.476). There are no differences when using covered self-expandable stents or uncovered self-expandable stents in terms of technical and clinical success or complications in the palliative treatment of malignant obstructive jaundice.

  17. Stent selection for both biliary and pancreatic strictures caused by chronic pancreatitis: multiple plastic stents or metallic stents?

    PubMed

    Gupta, Rajesh; Reddy, D Nageshwar

    2011-09-01

    Endoscopic stenting is an effective treatment option in the management of both benign biliary strictures and pancreatic ductal strictures. Plastic stents and self-expandable metal stents have been used with variable success for the management of both benign biliary strictures and pancreatic ductal strictures caused by chronic pancreatitis. Fully covered self-expandable metal stents of improved design represent a major technological advance which has added to the endoscopic armamentarium. Both multiple plastic stents and covered self-expandable metal stents have shown promising results. However, data to support the use of self-expandable metal stents over multiple plastic stents or vice versa are still lacking.

  18. Difficult removal of fully covered self expandable metal stents (SEMS) for benign biliary strictures: the "SEMS in SEMS" technique.

    PubMed

    Tringali, Andrea; Blero, Daniel; Boškoski, Ivo; Familiari, Pietro; Perri, Vincenzo; Devière, Jacques; Costamagna, Guido

    2014-06-01

    Removal of biliary Fully Covered Self Expandable Metal Stents can fail due to stent migration and/or hyperplastic ingrowth/overgrowth. A case series of 5 patients with benign biliary strictures (2 post-cholecystectomy, 2 following liver transplantation and 1 related to chronic pancreatitis) is reported. The biliary stricture was treated by temporary insertion of Fully Covered Self Expandable Metal Stents. Stent removal failed due to proximal stent migration and/or overgrowth. Metal stent removal was attempted a few weeks after the insertion of another Fully Covered Metal Stent into the first one. The inner Fully Covered Self Expandable Metal Stent compressed the hyperplastic tissue, leading to the extraction of both the stents in all cases. Two complications were reported as a result of the attempt to stents removal (mild pancreatitis and self-limited haemobilia). In the present series, the "SEMS in SEMS" technique revealed to be effective when difficulties are encountered during Fully Covered Self Expandable Metal Stents removal. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  19. An approach to tracheostomy in a patient with an expandable metallic tracheal stent.

    PubMed

    Madden, Brendan P; Sheth, Abhijat

    2005-09-01

    With increasing use of expandable metallic stents to manage patients with a variety of endobronchial pathologies, some will have a subsequent need for tracheostomy insertion. We describe a successful technique to insert a tracheostomy using rigid and fibre-optic bronchoscopy in a patient who had an 8 cm expandable metallic tracheal stent deployed previously on account of tracheomalacia.

  20. Public Attitudes Toward Expanded Newborn Screening.

    PubMed

    DeLuca, Jane M

    There is limited research available on public knowledge and understanding of expanded newborn screening (NBS). The aims of this study were to assess current public knowledge and understanding of newborn screening disorders and procedures, perceived education needs, and preferences for the delivery of NBS information and education. An additional aim was to develop a beginning understanding of public attitudes toward screening for complex, severe, and in some cases untreatable disorders. In this preliminary descriptive study, eighty-eight participants completed surveys querying their general knowledge of NBS, preferred means of receiving NBS information and education, and their opinions about screening for severe disorders such as lysosomal storage diseases (LSD). Most study participants lacked general knowledge about current NBS practices, however, they supported expanding screening for severe and in some cases untreatable conditions. Most participants were enthusiastic about expanding NBS; however, those with more years of education were cautious regarding extensive costs of diagnosing and treating rare disorders. Newborn screening continues to evolve through new technological developments and the addition of more disorders to screening panels. More research of into public acceptance of newborn screening is needed. Addressing the educational needs of the public is important for improving their understanding of NBS and promoting patient-centered care in the era of genomic screening. Enhanced educational efforts are necessary for improving public understanding of newborn screening. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Lessons Learned From A Study Of Genomics-Based Carrier Screening For Reproductive Decision Making.

    PubMed

    Wilfond, Benjamin S; Kauffman, Tia L; Jarvik, Gail P; Reiss, Jacob A; Richards, C Sue; McMullen, Carmit; Gilmore, Marian; Himes, Patricia; Kraft, Stephanie A; Porter, Kathryn M; Schneider, Jennifer L; Punj, Sumit; Leo, Michael C; Dickerson, John F; Lynch, Frances L; Clarke, Elizabeth; Rope, Alan F; Lutz, Kevin; Goddard, Katrina A B

    2018-05-01

    Genomics-based carrier screening is one of many opportunities to use genomic information to inform medical decision making, but clinicians, health care delivery systems, and payers need to determine whether to offer screening and how to do so in an efficient, ethical way. To shed light on this issue, we conducted a study in the period 2014-17 to inform the design of clinical screening programs and guide further health services research. Many of our results have been published elsewhere; this article summarizes the lessons we learned from that study and offers policy insights. Our experience can inform understanding of the potential impact of expanded carrier screening services on health system workflows and workforces-impacts that depend on the details of the screening approach. We found limited patient or health system harms from expanded screening. We also found that some patients valued the information they learned from the process. Future policy discussions should consider the value of offering such expanded carrier screening in health delivery systems with limited resources.

  2. Prevalence of Failure due to Adverse Reaction to Metal Debris in Modern, Medium and Large Diameter Metal-on-Metal Hip Replacements – The Effect of Novel Screening Methods: Systematic Review and Metaregression Analysis

    PubMed Central

    Reito, Aleksi; Lainiala, Olli; Elo, Petra; Eskelinen, Antti

    2016-01-01

    Metal-on-metal (MoM) hip replacements were used for almost a decade before adverse reactions to metal debris (ARMD) were found to be a true clinical problem. Currently, there is a paucity of evidence regarding the usefulness of systematic screening for ARMD. We implemented a systematic review and meta-analysis to establish the prevalence of revision confirmed ARMD stratified by the use of different screening protocols in patients with MoM hip replacements. Five levels of screening were identified: no screening (level 0), targeted blood metal ion measurement and/or cross-sectional imaging (level 1), metal ion measurement without imaging (level 2), metal ion measurement with targeted imaging (level 3) and comprehensive screening (both metal ions and imaging for all; level 4). 122 studies meeting our eligibility criteria were included in analysis. These studies included 144 study arms: 100 study arms with hip resurfacings, 33 study arms with large-diameter MoM total hip replacements (THR), and 11 study arms with medium-diameter MoM THRs. For hip resurfacing, the lowest prevalence of ARMD was seen with level 0 screening (pooled prevalence 0.13%) and the highest with level 4 screening (pooled prevalace 9.49%). Pooled prevalence of ARMD with level 0 screening was 0.29% and with level 4 screening 21.3% in the large-diameter MoM THR group. In metaregression analysis of hip resurfacings, level 4 screening was superior with regard to prevalence of ARMD when compared with other levels. In the large diameter THR group level 4 screening was superior to screening 0,2 and 3. These outcomes were irrespective of follow-up time or study publication year. With hip resurfacings, routine cross-sectional imaging regardless of clinical findings is advisable. It is clear, however, that targeted metal ion measurement and/or imaging is not sufficient in the screening for ARMD in any implant concepts. However, economic aspects should be weighed when choosing the preferred screening level. PMID:26930057

  3. Expandable metallic stents for tracheobronchial stenoses in esophageal cancer.

    PubMed

    Takamori, S; Fujita, H; Hayashi, A; Tayama, K; Mitsuoka, M; Ohtsuka, S; Shirouzu, K

    1996-09-01

    Tracheobronchial stenosis in patients with esophageal cancer can be life threatening. Few reports have discussed use of expandable metallic stents for central airway stenoses in patients with esophageal cancer. Twelve patients with esophageal cancer underwent placement of expandable metallic stents for respiratory distress caused by tracheobronchial stricture. Single or double metallic stents were placed in the stenotic airways under fluoroscopic guidance. Improvement in respiratory symptoms and clinical outcome were assessed. Most stenoses were located in the trachea or the left main bronchus. From one to four expandable metallic stents were placed in each stricture site, with immediate relief of respiratory symptoms in 8 patients. One patient with tracheomalacia in alive 3 years after stent placement and another is alive 6 months after stent insertion. The other 10 patients lived from 10 to 70 days (mean; survival, 35 days) after stent placement. Death was due to progression of disease. Although metallic stents are useful for relieving respiratory distress in patients with advanced esophageal cancer, additional therapies should be considered.

  4. Long-term outcome of self expandable metal stents for biliary obstruction in chronic pancreatitis.

    PubMed

    Waldthaler, Alexander; Schütte, Kerstin; Weigt, Jochen; Kropf, Siegfried; Malfertheiner, Peter; Kahl, Stefan

    2013-01-10

    Insertion of a self-expandable metal stent is still controversial for treatment of benign common bile duct stenosis but can be a valuable alternative to surgical treatment. Aim of our study was to analyze the efficacy of covered and uncovered self-expandable metal stent in patients with chronic pancreatitis and common bile duct stenosis. Twenty patients with common bile duct stenosis due to alcoholic chronic pancreatitis were retrospective analyzed. All patients had advanced chronic pancreatitis, presenting with calcifications in pancreatic head. Uncovered self-expandable metal stent (uSEMS) were used in 11 patients (3 females, 8 males) while in 9 patients (3 females, 6 males) partially covered self-expandable metal stent (cSEMS) were inserted. All patients treated with self-expandable metal stent had contraindications for surgery. Overall mean follow up time was 155 weeks: 206 (52-412) weeks in uSEMS, and 93 (25-233) weeks in cSEMS, respectively. Stent patency was in mean 118 weeks: 159 (44-412) weeks in uSEMS and 67 (25-150) weeks in cSEMS (P=0.019). In the uSEMS group, reintervention was necessary in 5 patients (45%) due to stent obstruction, whereas in the cSEMS group 4 patients (44%) needed reintervention (2 obstructions, 2 migration). Stent migration is an early complication, compared to obstruction (P<0.05), and in cSEMS obstruction occurred significantly earlier compared to uSEMS (P<0.05). Patency of uSEMS was significantly longer compared to partially cSEMS. Available self-expandable metal stent, unfortunately, do not meet the demands on successful treatment of benign common bile duct stenosis.

  5. Experiences among Women with Positive Prenatal Expanded Carrier Screening Results.

    PubMed

    Rothwell, Erin; Johnson, Erin; Mathiesen, Amber; Golden, Kylie; Metcalf, Audrey; Rose, Nancy C; Botkin, Jeffrey R

    2017-08-01

    The offering and acceptance of expanded carrier screening is increasing among pregnant women including women without an increased risk based on race, ethnicity or family history. The chances of a positive screening test have been reported to be as high as 24 % when multiple conditions are screened. Yet, little is known about the way these tests are offered and how patients are affected by a positive test result. To explore this area of genetic testing, interviews (n = 17) were conducted among women who received positive expanded carrier results in the context of obstetric care. A content analysis was conducted on the transcript data from the interviews. Outcomes of this research suggest that educational interventions are needed to improve maternal understanding of positive carrier screening results. Most of the participants in this study confused the results with other prenatal screening test options. In addition, the way the results were discussed varied greatly, and influenced participants' thoughts about reproductive decisions that led to a range of emotional uncertainty. Our data suggests that genetic counseling improved participants' understanding of positive results. More research is needed to further understand if our results are consistent within a larger, more diverse sample, and to explore how to best provide education about expanded carrier screening.

  6. Parental views on informed consent for expanded newborn screening.

    PubMed

    Moody, Louise; Choudhry, Kubra

    2013-09-01

    An increasing array of rare inherited conditions can be detected as part of the universal newborn screening programme. The introduction and evaluation of these service developments require consideration of the ethical issues involved and appropriate mechanisms for informing parents and gaining consent if required. Exploration of parental views is needed to inform the debate and specifically consider whether more flexible protocols are needed to fit with the public perception of new developments in this context. This study has been undertaken to explore perceptions and attitudes of parents and future parents to an expanded newborn screening programme in the United Kingdom and the necessary information provision and consent processes. A mixed methods study involving focus groups (n = 29) and a web-survey (n = 142) undertaken with parents and future parents. Parents want guaranteed information provision with clear decision-making powers and an awareness of the choices available to them. The difference between existing screening provision and expanded screening was not considered to be significant enough by participants to warrant formal written, informed consent for expanded screening. It is argued that the ethical review processes need to be more flexible towards the provision of information and consent processes for service developments in newborn screening. © 2011 John Wiley & Sons Ltd.

  7. Expanded Enlistment Eligibility Metrics (EEEM): Recommendations on a Non-Cognitive Screen for New Soldier Selection

    DTIC Science & Technology

    2010-07-01

    applicants and is pursing further research on the WPA. An operational test and evaluation ( IOT &E) has been initiated to evaluate the new screen...initial operational test and evaluation ( IOT &E) starting in fall 2009. vii EXPANDED ENLISTMENT ELIGIBILITY METRICS (EEEM): RECOMMENDATIONS ON A NON...Evaluation of a Performance Screen for IOT &E ..................................... 49 Approach

  8. Safety and efficacy of self-expandable metal stents for obstructive proximal and distal large bowel cancer.

    PubMed

    Mitra, V; Hu, M; Majumdar, D; Krishnan, V; Chaudhury, B; Hancock, J; Dwarakanath, D

    2017-03-01

    Self-expandable metal stents are often used to treat obstructive large bowel cancers. This study assessed the safety and efficacy of colonic stent insertion carried out in a district general hospital. Methods A retrospective review was carried out between 1 January 2007 and 28 February 2014 to identify patients who underwent stent insertion for malignant colorectal obstruction. Results Seventy-five patients (median age 75.2 years, 70.6% male) with primary colorectal cancer underwent stent insertion - 53 underwent semi-elective self-expanded metal stent insertion (for subacute bowel obstruction) and 22 had emergency stent inserted (for acute bowel obstruction). The majority (88%) had self-expanded metal stents inserted for palliation. Technical and clinical success rates were 98.7% and 91.2%, respectively. One patient had stent-related perforation; there was no procedure-related mortality. Conclusion This study shows that self-expanded metal stent insertion in malignant colorectal obstruction is safe and effective and can be successfully delivered in a district general hospital with high technical and clinical success rates.

  9. Chemotherapy versus self-expanding metal stent as primary treatment of severe dysphagia from unresectable oesophageal or gastro-oesophageal junction cancer.

    PubMed

    Touchefeu, Yann; Archambeaud, Isabelle; Landi, Bruno; Lièvre, Astrid; Lepère, Céline; Rougier, Philippe; Mitry, Emmanuel

    2014-03-01

    To compare chemotherapy first (group 1) versus self-expanding metal stent first (group 2) for the management of malignant dysphagia in unresectable oesophageal or gastro-oesophageal junction cancer. Patients from two university hospitals with severe malignant dysphagia (dysphagia score ≥ 2) uneligible for surgery or radiochemotherapy were evaluated retrospectively. Forty-two patients were included in group 1, and 29 in group 2. After 4 weeks, dysphagia scores improved by at least 1 point in 67% of patients in group 1 versus 93% in group 2 (p=0.01); 48% of patients in group 1 were able to eat solid food versus 68% in group 2 (p=0.054). In group 1, a self-expanding metal stent was secondarily placed in 18 patients (42.9%), whereas in group 2 dysphagia required a second self-expanding metal stent placement in 33.3% of patients. Chemotherapy as the first treatment may be a valid option, avoiding self-expanding metal stent insertion in half of the patients. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. Self-expandable metal stents in the treatment of benign anastomotic stricture after rectal resection for cancer.

    PubMed

    Lamazza, A; Fiori, E; Sterpetti, A V; Schillaci, A; Scoglio, D; Lezoche, E

    2014-04-01

    To evaluate the use of self-expandable metallic stents to treat patients with symptomatic benign anastomotic stricture after colorectal resection. Ten patients with a benign symptomatic anastomotic stricture after colorectal resection were treated with endoscopic placement of a self-expandable metal stent. The stent was placed successfully in all 10 patients without any major morbidity. At a mean follow-up of 18 months the stenosis was resolved successfully in 7 out 10 patients (70%). The remaining three patients were subsequently treated successfully with balloon dilatation. Self-expandable metal stents represent a valid alternative to balloon dilatation to treat patients with benign symptomatic anastomotic stricture after colorectal resection for cancer. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  11. Numerical simulation of a novel expanded metal tubular structure for crashworthiness application

    NASA Astrophysics Data System (ADS)

    Abdelaal, A. H. A.; Tarlochan, F.

    2015-12-01

    Search for new geometries and materials that would serve in crashworthiness applications is a cumulative process. Recent studies investigated the performance of expanded metal tubes and the possible ways to enhance its energy absorption capability. The aim of this work is to investigate the crashworthiness characteristics of new concept is proposed where expanded metal tube is suited into a double-walled tube made of the same material to form one structure. The tube was then numerically tested through a verified model using ABAQUS software. Moreover, the influence of the size of the expanded metal cell was also investigated in the present study. The new concept showed an enhanced energy absorption characteristics related to the change in the mass of the tubular structure. The enhancement was related to both the change in deformation pattern, and the increase in crushed mass.

  12. Increased metal concentrations in exhaled breath condensate of industrial welders.

    PubMed

    Hoffmeyer, Frank; Weiss, Tobias; Lehnert, Martin; Pesch, Beate; Berresheim, Hans; Henry, Jana; Raulf-Heimsoth, Monika; Broding, Horst Christoph; Bünger, Jürgen; Harth, Volker; Brüning, Thomas

    2011-01-01

    It was the aim of this study to evaluate the effect of different devices on the metal concentration in exhaled breath condensate (EBC) and to prove whether working conditions in different welding companies result in diverse composition of metallic elements. The influence of two collection devices (ECoScreen, ECoScreen2) on detection of metallic elements in EBC was evaluated in 24 control subjects. Properties of ECoScreen and a frequent use can alter EBC metal content due to contamination from metallic components. ECoScreen2 turned out to be favourable for metal assessment. Concentrations of iron, nickel and chromium in EBC sampled with ECoScreen2 were compared between non-exposed controls and industrial welders. Metal concentrations in EBC were higher in 36 welders recruited from three companies. Exposure to welding fumes could be demonstrated predominantly for increased iron concentrations. Concentrations of iron and nickel differed by working conditions, but chromium could not be detected in EBC.

  13. Cost-benefit analysis of hyperphenylalaninemia due to 6-pyruvoyl-tetrahydropterin synthase (PTPS) deficiency: for consideration of expanded newborn screening in Hong Kong.

    PubMed

    Lee, Hencher Han-Chih; Mak, Chloe Miu; Poon, Grace Wing-Kit; Wong, Kar-Yin; Lam, Ching-Wan

    2014-06-01

    To evaluate the cost-benefit of implementing an expanded newborn screening programme for hyperphenylalaninemias due to 6-pyruvoyl-tetrahydropterin synthase (PTPS) deficiency in Hong Kong. Regional public hospitals in Hong Kong providing care for cases of inborn errors of metabolism. Implementational and operational costs of a new expanded mass spectrometry-based newborn screening programme were estimated. Data on various medical expenditures for the mild and severe phenotypic subtypes were gathered from a case cohort diagnosed with PTPS deficiency from 2001 to 2009. Local incidence from a previously published study was used. Implementation and operational costs of an expanded newborn screening programme in Hong Kong were estimated at HKD 10,473,848 (USD 1,342,801) annually. Assuming a birthrate of 50,000 per year and an incidence of 1 in 29,542 live births, the medical costs and adjusted loss of workforce per year would be HKD 20,773,207 (USD 2,663,232). Overall the annual savings from implementing the programme would be HKD 9,632,750 (USD 1,234,968). Our estimates show that implementation of an expanded newborn screening programme in Hong Kong is cost-effective, with a significant annual saving for public expenditure. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Functional Self-Expandable Metal Stents in Biliary Obstruction

    PubMed Central

    Kwon, Chang-Il; Ko, Kwang Hyun; Hahm, Ki Baik

    2013-01-01

    Biliary stents are widely used not only for palliative treatment of malignant biliary obstruction but also for benign biliary diseases. Each plastic stent or self-expandable metal stent (SEMS) has its own advantages, and a proper stent should be selected carefully for individual condition. To compensate and overcome several drawbacks of SEMS, functional self-expandable metal stent (FSEMS) has been developed with much progress so far. This article looks into the outcomes and defects of each stent type for benign biliary stricture and describes newly introduced FSEMSs according to their functional categories. PMID:24143314

  15. Obstruction after Self-expanding Metallic Stents in Tuberculous Bronchial Stenosis

    PubMed Central

    Kim, Won; Lee, Youg Chul; Rhee, Yang Keun

    1995-01-01

    Expandable metallic stents seemed to be a good method in tuberculous bronchial stenosis that does not respond to medical therapy. But there was no long-term follow-up study after stents insertion in tuberculous bronchial stenosis. We report a case of obstruction after successful Gianturco metallic stents insertion due to tuberculous bronchial stenosis. PMID:7542914

  16. Newborn screening: new developments, new dilemmas.

    PubMed

    Kerruish, N J; Robertson, S P

    2005-07-01

    Scientific and technological advances are lending pressure to expand the scope of newborn screening. Whereas this has great potential for improving child health, it also challenges our current perception of such programmes. Standard newborn screening programmes are clearly justified by the fact that early detection and treatment of affected individuals avoids significant morbidity and mortality. However, proposals to expand the scope and complexity of such testing are not all supported by a similar level of evidence for unequivocal benefit. We argue that screening for genetic susceptibility to complex disorders is inherently different from standard screening and, while of potential value, must be considered separately from conventional testing.

  17. Parental Intentions to Enroll Children in a Voluntary Expanded Newborn Screening Program

    PubMed Central

    Paquin, Ryan S.; Peay, Holly L.; Gehtland, Lisa M.; Lewis, Megan A.; Bailey, Donald B.

    2016-01-01

    Background and Objectives Nearly all babies in the United States are tested at birth for rare, serious, and treatable disorders through mandatory state newborn screening (NBS). Recently, there have been calls for an expanded, voluntary model to facilitate early diagnosis and treatment of a wider range of disorders. We applied the reasoned action framework to examine parental intentions to participate in voluntary expanded screening. Methods We recruited a national cohort of recent and expectant parents living in the U.S. who completed a self-administered online survey (N = 1,001). Using a mixed-level fractional factorial experiment, we studied parental participation intentions and preferences for timing of consent, cost, consent format, and testing options. Results We conducted a hierarchical regression analysis assessing parental intentions to participate in voluntary expanded NBS. Attitudes, perceived normative influence, and perceived behavioral control explained substantial variance in intention, with perceived normative influence emerging as the strongest predictor. We found no evidence that the manipulated program features altered mean levels of intention, but timing of parental permission, cost, and permission format moderated the relative importance of reasoned action constructs on intention. Conclusion Program design features may impact the psychological mechanisms underlying parental decision making for voluntary expanded screening. These results have important implications for parent education, outreach, and informed parental permission procedures. PMID:27526258

  18. Expanded newborn metabolic screening programme in Hong Kong: a three-year journey.

    PubMed

    Chong, S C; Law, L K; Hui, J; Lai, C Y; Leung, T Y; Yuen, Y P

    2017-10-01

    No universal expanded newborn screening service for inborn errors of metabolism is available in Hong Kong despite its long history in developed western countries and rapid development in neighbouring Asian countries. To increase the local awareness and preparedness, the Centre of Inborn Errors of Metabolism of the Chinese University of Hong Kong started a private inborn errors of metabolism screening programme in July 2013. This study aimed to describe the results and implementation of this screening programme. We retrieved the demographics of the screened newborns and the screening results from July 2013 to July 2016. These data were used to calculate quality metrics such as call-back rate and false-positive rate. Clinical details of true-positive and false-negative cases and their outcomes were described. Finally, the call-back logistics for newborns with positive screening results were reviewed. During the study period, 30 448 newborns referred from 13 private and public units were screened. Of the samples, 98.3% were collected within 7 days of life. The overall call-back rate was 0.128% (39/30 448) and the false-positive rate was 0.105% (32/30 448). Six neonates were confirmed to have inborn errors of metabolism, including two cases of medium-chain acyl-coenzyme A dehydrogenase deficiency, one case of carnitine-acylcarnitine translocase deficiency, and three milder conditions. One case of maternal carnitine uptake defect was diagnosed. All patients remained asymptomatic at their last follow-up. The Centre of Inborn Errors of Metabolism has established a comprehensive expanded newborn screening programme for selected inborn errors of metabolism. It sets a standard against which the performance of other private newborn screening tests can be compared. Our experience can also serve as a reference for policymakers when they contemplate establishing a government-funded universal expanded newborn screening programme in the future.

  19. Closed cell metal foam method

    DOEpatents

    Patten, James W.

    1978-01-01

    Foamed metals and metal alloys which have a closed cellular structure are prepared by heating a metal body containing entrapped inert gas uniformly distributed throughout to a temperature above the melting point of the metal and maintaining the body at this temperature a period of time sufficient to permit the entrapped gas to expand, forming individual cells within the molten metal, thus expanding and foaming the molten metal. After cell formation has reached the desired amount, the foamed molten metal body is cooled to below the melting temperature of the metal. The void area or density of the foamed metal is controlled by predetermining the amount of inert gas entrapped in the metal body and by the period of time the metal body is maintained in the molten state. This method is useful for preparing foamed metals and metal alloys from any metal or other material of which a body containing entrapped inert gas can be prepared.

  20. Screening Methods for Metal-Containing Nanoparticles in Water

    EPA Science Inventory

    Screening-level analysis of water for metal-containing nanoparticles is achieved with single particle-inductively coupled plasma mass spectrometry (SP-ICPMS). This method measures both the concentration of nanoparticles containing an analyte metal and the mass of the metal in eac...

  1. Dynamic polarizability of tungsten atoms reconstructed from fast electrical explosion of fine wires in vacuum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarkisov, G. S.; Rosenthal, S. E.; Struve, K. W.

    For nanosecond electrical explosion of fine metal wires in vacuum generates calibrated, radially expanded gas cylinders of metal atoms are surrounded by low-density fast expanding plasma corona. Here, a novel integrated-phase technique, based on laser interferometry, provides the dynamic dipole polarizability of metal atoms. This data was previously unavailable for tungsten atoms. Furthermore, an extremely high melting temperature and significant pre-melt electronic emission make these measurements particularly complicated for this refractory metal.

  2. Dynamic polarizability of tungsten atoms reconstructed from fast electrical explosion of fine wires in vacuum

    DOE PAGES

    Sarkisov, G. S.; Rosenthal, S. E.; Struve, K. W.

    2016-10-12

    For nanosecond electrical explosion of fine metal wires in vacuum generates calibrated, radially expanded gas cylinders of metal atoms are surrounded by low-density fast expanding plasma corona. Here, a novel integrated-phase technique, based on laser interferometry, provides the dynamic dipole polarizability of metal atoms. This data was previously unavailable for tungsten atoms. Furthermore, an extremely high melting temperature and significant pre-melt electronic emission make these measurements particularly complicated for this refractory metal.

  3. Thoracic Discitis as a Complication of Self-Expanding Metallic Stents in Esophageal Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McQueen, A. S.; Eljabu, W.; Latimer, J., E-mail: joanne.latimer@nth.nhs.uk

    2011-02-15

    The role of metallic stents in the palliation of esophageal cancer is well established. Self-expanding metal stents (SEMSs) are frequently used, as they provide an effective and safe method of relieving malignant dysphagia. A number of complications are associated with the use of SEMSs, including esophageal perforation. We report a case of thoracic discitis occurring in a patient with advanced esophageal malignancy, treated with SEMSs. We propose that the likely etiology in this patient was esophageal perforation by a metallic stent.

  4. Patient actions and reactions after receiving negative results from expanded carrier screening

    PubMed Central

    Kraft, Stephanie A.; Schneider, Jennifer L.; Leo, Michael C.; Kauffman, Tia L.; Davis, James V.; Porter, Kathryn M.; McMullen, Carmit K.; Wilfond, Benjamin S.; Goddard, Katrina A.B.

    2018-01-01

    With the expansion of carrier screening to general preconception and prenatal patient populations, most patients will receive negative results, which we define as indicating <25% risk of having a child with a genetic condition. Because there is limited experience with expanded carrier screening, it is important to understand how receiving negative results affects patients, especially as providers, payers, and policymakers consider whether to offer it. In this mixed-methods study, we asked preconception patients enrolled in the NextGen study about their expectations and experiences receiving negative expanded carrier screening results. Participants completed surveys at study enrollment (n=110 women, 51 male partners), after receiving carrier results (n=100 women, 38 male partners), after receiving secondary findings (n=98 women, 36 male partners), and 6 months after receiving results (n=95 women, 28 male partners). We also interviewed a subset of participants 12–24 months after receiving results (n=24 women, 12 male partners). We found minimal negative emotional impact and privacy concerns, increased confidence in reproductive plans, and few changes to health behaviors, although some patients made health decisions based on misunderstandings of their results. These findings suggest that expanded carrier screening causes minimal psychosocial harms, but systems are needed to reduce the risk of misinterpreting results. PMID:29293279

  5. Expanded newborn screening: social and ethical issues.

    PubMed

    Dhondt, Jean-Louis

    2010-10-01

    Newborn screening and genetic testing have expanded rapidly in the last decade with the advent of multiplex (e.g., tandem mass spectrometry) and/or DNA technologies. However, screening panels include a large number of disorders, which may not meet all of the traditional screening criteria, established in late 1960s, and used for years to justify screening programs. After a period of expansion driven by technological advances, many reports have reconsidered the justification of expanded programs. Many factors have contributed to test-panel discrepancies between countries. The test-panel review methodology, the way health benefits are weighed against harms, and the socioeconomic-political environment all play a role. Expansion of screening also requires reconsideration of the infrastructure (ideally, in the context of national plans for rare diseases) to support testing, counselling, education, treatment, and follow-up. Consequently, economic aspects cannot be ignored and can be a limitation for expansion. New ethical questions have emerged: risks of discrimination or stigmatization, respect of the autonomy of persons to make decisions, parental anxiety resulting from a false positive test (especially when reporting to parents screening results for untreatable conditions identified as by-products of screening), etc. For disorders where there is not yet confirmation of benefit, it may be prudent to recommend pilot screening and to have a mechanism that can be used to adapt or even to stop a program.

  6. Impact of expanded newborn screening--United States, 2006.

    PubMed

    2008-09-19

    Universal newborn screening for selected metabolic, endocrine, hematologic, and functional disorders is a well-established practice of state public health programs. Recent developments in tandem mass spectrometry (MS/MS), which is now capable of multi-analyte analysis in a high throughput capacity, has enabled newborn screening to include many more disorders detectable from a newborn blood spot. In 2006, to address the substantial variation that existed from state to state in the number of disorders included in newborn screening panels, the American College of Medical Genetics (ACMG), under guidance from the Health Resources and Services Administration, recommended a uniform panel of 29 disorders, which was subsequently endorsed by the federal Advisory Committee on Heritable Disorders in Newborns and Children. After 2006, most states began to expand their panels to include all 29 disorders; currently, 21 states and the District of Columbia have fully implemented the ACMG panel. To estimate the burden to state newborn screening programs resulting from this expansion, CDC used 2001-2006 data from those states with well-established MS/MS screening programs to estimate the number of children in the United States who would have been identified with disorders in 2006 if all 50 states and the District of Columbia had been using the ACMG panel. This report describes the results of that analysis, which indicated that, although such an expansion would have increased the number of children identified by only 32% (from 4,370 to 6,439), these children would have had many rare disorders that require local or regional capacity to deliver expertise in screening, diagnosis, and management. The findings underscore the need for public health and health-care delivery systems to build or expand the programs required to manage the rare disorders detected through expanded newborn screening, while also continuing programs to address more common disorders.

  7. Prevention, screening and treatment of colorectal cancer: a global and regional generalized cost effectiveness analysis

    PubMed Central

    2010-01-01

    Background Regional generalized cost-effectiveness estimates of prevention, screening and treatment interventions for colorectal cancer are presented. Methods Standardised WHO-CHOICE methodology was used. A colorectal cancer model was employed to provide estimates of screening and treatment effectiveness. Intervention effectiveness was determined via a population state-transition model (PopMod) that simulates the evolution of a sub-regional population accounting for births, deaths and disease epidemiology. Economic costs of procedures and treatment were estimated, including programme overhead and training costs. Results In regions characterised by high income, low mortality and high existing treatment coverage, the addition of screening to the current high treatment levels is very cost-effective, although no particular intervention stands out in cost-effectiveness terms relative to the others. In regions characterised by low income, low mortality with existing treatment coverage around 50%, expanding treatment with or without screening is cost-effective or very cost-effective. Abandoning treatment in favour of screening (no treatment scenario) would not be cost effective. In regions characterised by low income, high mortality and low treatment levels, the most cost-effective intervention is expanding treatment. Conclusions From a cost-effectiveness standpoint, screening programmes should be expanded in developed regions and treatment programmes should be established for colorectal cancer in regions with low treatment coverage. PMID:20236531

  8. Precast/Prestressed Concrete Experiments Performance on Non-Load Bearing Sandwich Wall Panels

    DTIC Science & Technology

    2011-01-01

    expanded polystyrene (EPS), extruded expanded polystyrene (XPS...34 Ø Strands @ 14.9 kips 3/8" Ø Strands @ 14.9 kips 9" #3@18" XEPS Insulation Extruded Expanded Polystyrene 4" (Metal C-Pins) Metal C-Pins 1’-8" 3" 3...34 3" 8" 1’-4" 8" 2’-8" 11 2 " 6" 11 2 " 3/8" Ø Strands @ 14.9 kips 3/8" Ø Strands @ 14.9 kips 9" #3@18" XEPS Insulation Extruded Expanded Polystyrene

  9. Expander for Thin-Wall Tubing

    NASA Technical Reports Server (NTRS)

    Pessin, R.

    1983-01-01

    Tool locally expands small-diameter tubes. Tube expander locally expands and deforms tube: Compressive lateral stress induced in elastomeric sleeve by squeezing axially between two metal tool parts. Adaptable to situations in which tube must have small bulge for mechanical support or flow control.

  10. Patient actions and reactions after receiving negative results from expanded carrier screening.

    PubMed

    Kraft, S A; Schneider, J L; Leo, M C; Kauffman, T L; Davis, J V; Porter, K M; McMullen, C K; Wilfond, B S; Goddard, K A B

    2018-05-01

    With the expansion of carrier screening to general preconception and prenatal patient populations, most patients will receive negative results, which we define as indicating <25% risk of having a child with a genetic condition. Because there is limited experience with expanded carrier screening, it is important to understand how receiving negative results affects patients, especially as providers, payers, and policymakers consider whether to offer it. In this mixed-methods study, we asked preconception patients enrolled in the NextGen study about their expectations and experiences receiving negative expanded carrier screening results. Participants completed surveys at study enrollment (n = 110 women, 51 male partners), after receiving carrier results (n = 100 women, 38 male partners), after receiving secondary findings (n = 98 women, 36 male partners), and 6 months after receiving results (n = 95 women, 28 male partners). We also interviewed a subset of participants 12 to 24 months after receiving results (n = 24 women, 12 male partners). We found minimal negative emotional impact and privacy concerns, increased confidence in reproductive plans, and few changes to health behaviors, although some patients made health decisions based on misunderstandings of their results. These findings suggest that expanded carrier screening causes minimal psychosocial harms, but systems are needed to reduce the risk of misinterpreting results. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. The challenge of screen printed Ag metallization on nano-scale poly-silicon passivated contacts for silicon solar cells

    NASA Astrophysics Data System (ADS)

    Jiang, Lin; Song, Lixin; Yan, Li; Becht, Gregory; Zhang, Yi; Hoerteis, Matthias

    2017-08-01

    Passivated contacts can be used to reduce metal-induced recombination for higher energy conversion efficiency for silicon solar cells, and are obtained increasing attentions by PV industries in recent years. The reported thicknesses of passivated contact layers are mostly within tens of nanometer range, and the corresponding metallization methods are realized mainly by plating/evaporation technology. This high cost metallization cannot compete with the screen printing technology, and may affect its market potential comparing with the presently dominant solar cell technology. Very few works have been reported on screen printing metallization on passivated contact solar cells. Hence, there is a rising demand to realize screen printing metallization technology on this topic. In this work, we investigate applying screen printing metallization pastes on poly-silicon passivated contacts. The critical challenge for us is to build low contact resistance that can be competitive to standard technology while restricting the paste penetrations within the thin nano-scale passivated contact layers. The contact resistivity of 1.1mohm-cm2 and the open circuit voltages > 660mV are achieved, and the most appropriate thickness range is estimated to be around 80 150nm.

  12. High resolution photoemission investigation: The oxidation of W

    NASA Astrophysics Data System (ADS)

    Morar, J. F.; Himpsel, F. J.; Hughes, G. J.; Jordan, J. L.; McFeely, F. R.; Hollinge, G.

    High resolution photoemission measurements of surface oxide layers on tungsten has revealed a set of well resolved core level shifts characteristic of individual metal oxidation states. Measurement and analysis of this type of data can provide specific and quantitative chemical information about surface oxides. The formation of bonds between transition metals and strongly electronegative elements such as oxygen and fluorine results in charge transfer with the effect of shifting the metal core electron binding energies. The magnitude of such shifts depends primarily on two factors; the amount of charge transfer and the screening ability of the metals electrons. The size of core-level shifts tend to increase with additional charge transfer and be decreased by screening. In the case of tungsten the amount of screening should be a function of oxygen content since the oxygen ties up free electrons which are effective at screening. A continuous change in the tungsten core level shifts is observed with increasing oxygen content, i.e., as the screening changes from that characteristic of a metal screened to that characteristic of an insulator unscreened.

  13. Fully Covered Self-Expandable Metal Stents for Treatment of Both Benign and Malignant Biliary Disorders

    PubMed Central

    Abdel Samie, Ahmed; Theilmann, Lorenz

    2012-01-01

    Transpapillary stents are increasingly being used for biliary strictures, whether benign or malignant. However, there are different stent types and available data is controversial. Recently, completely covered self-expandable metal stents (CSEMSs) have been proposed as an alternative therapeutic option in different biliary indications, including strictures of the distal bile duct, anastomotic stenosis after orthotopic liver transplantation, bile duct leaks, periampullary perforation following endoscopic sphincterotomy (ES), and postsphincterotomy bleeding. Despite the higher costs of these devices, fully covered self-expanding metal stents seem to be a suitable therapeutic option to relief biliary obstruction due to bile duct stenosis, regardless of the underlying cause. PMID:22761543

  14. Internally folded expanded metal electrode for battery construction

    NASA Technical Reports Server (NTRS)

    Pierce, Doug C. (Inventor); Korinek, Paul D. (Inventor); Morgan, Maurice C. (Inventor)

    1993-01-01

    A battery system is disclosed which includes folded grids of expanded metal inserted through non-conductive substrates and pasted with electrochemically active materials. In the most preferred embodiment, a frame is provided with a plastic insert, and slots are provided in the latter to receive the expanded metal grid. After suitable coinage of the grid and insertion through the plastic film, the grid is sealed and pasted on opposite sides with positive and negative active material. A battery is assembled using one or a plurality of the resulting electrode elements, with separators, to produce a high-power, lead-acid battery. The folded grid provides many of the design benefits of standard bipolar construction.

  15. State Medicaid expansion decisions and disparities in women's cancer screening.

    PubMed

    Sabik, Lindsay M; Tarazi, Wafa W; Bradley, Cathy J

    2015-01-01

    There are substantial disparities in breast and cervical cancer screening that stem from lack of health insurance. Although the Affordable Care Act (ACA) expands insurance coverage to many Americans, there are differences in availability of Medicaid coverage across states. To understand the potential impact of Medicaid expansions on disparities in preventive care for low-income women by assessing pre-ACA breast and cervical cancer screening across states currently expanding and not expanding Medicaid to low-income adults. Data from the 2012 Behavioral Risk Factor Surveillance System (analyzed in 2014) were used to consider differences in demographics among women for whom screening is recommended, including income and race/ethnicity, across expansion and nonexpansion states. Self-reported screening was compared by state expansion status overall, for the uninsured, and for low-income women. Logistic regressions were estimated to assess differences in self-reported screening across expansion and nonexpansion states controlling for demographics. Women in states that are not expanding Medicaid had significantly lower odds of receiving recommended mammograms (OR=0.87, 95% CI=0.79, 0.95) or Pap tests (OR=0.87, 95% CI=0.79, 0.95). The difference was larger among the uninsured (OR=0.72, 95% CI=0.56, 0.91 for mammography; OR=0.78, 95% CI=0.65, 0.94 for Pap tests). As women in nonexpansion states remain uninsured and others gain coverage, existing disparities in cancer screening by race and socioeconomic status are likely to widen. Health risks and associated costs to underserved populations must be taken into account in ongoing debates over expansion. Copyright © 2015 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  16. Pre- and post-test genetic counseling for chromosomal and Mendelian disorders.

    PubMed

    Fonda Allen, Jill; Stoll, Katie; Bernhardt, Barbara A

    2016-02-01

    Genetic carrier screening, prenatal screening for aneuploidy, and prenatal diagnostic testing have expanded dramatically over the past 2 decades. Driven in part by powerful market forces, new complex testing modalities have become available after limited clinical research. The responsibility for offering these tests lies primarily on the obstetrical care provider and has become more burdensome as the number of testing options expands. Genetic testing in pregnancy is optional, and decisions about undergoing tests, as well as follow-up testing, should be informed and based on individual patients' values and needs. Careful pre- and post-test counseling is central to supporting informed decision-making. This article explores three areas of technical expansion in genetic testing: expanded carrier screening, non-invasive prenatal screening for fetal aneuploidies using cell-free DNA, and diagnostic testing using fetal chromosomal microarray testing, and provides insights aimed at enabling the obstetrical practitioner to better support patients considering these tests. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. To expand coverage, or increase frequency: Quantifying the tradeoffs between equity and efficiency facing cervical cancer screening programs in low‐resource settings

    PubMed Central

    Tsu, Vivien; Jeronimo, Jose; Mvundura, Mercy; Lee, Kyueun; Kim, Jane J.

    2017-01-01

    Cervical cancer is a leading cause of cancer death worldwide, with 85% of the disease burden residing in less developed regions. To inform evidence‐based decision‐making as cervical cancer screening programs are planned, implemented, and scaled in low‐ and middle‐income countries, we used cost and test performance data from the START‐UP demonstration project in Uganda and a microsimulation model of HPV infection and cervical carcinogenesis to quantify the health benefits, distributional equity, cost‐effectiveness, and financial impact of either (1) improving access to cervical cancer screening or (2) increasing the number of lifetime screening opportunities for women who already have access. We found that when baseline screening coverage was low (i.e., 30%), expanding coverage of screening once in a lifetime to 50% can yield comparable reductions in cancer risk to screening two or three times in a lifetime at 30% coverage, lead to greater reductions in health disparities, and cost 150 international dollars (I$) per year of life saved (YLS). At higher baseline screening coverage levels (i.e., 70%), screening three times in a lifetime yielded greater health benefits than expanding screening once in a lifetime to 90% coverage, and would have a cost‐effectiveness ratio (I$590 per YLS) below Uganda's per capita GDP. Given very low baseline coverage at present, we conclude that a policy focus on increasing access for previously unscreened women appears to be more compatible with improving both equity and efficiency than a focus on increasing frequency for a small subset of women. PMID:27925175

  18. The use of balloon-expandable metallic stents in the treatment of pediatric tracheomalacia and bronchomalacia.

    PubMed

    Furman, R H; Backer, C L; Dunham, M E; Donaldson, J; Mavroudis, C; Holinger, L D

    1999-02-01

    To evaluate the use of balloon-expandable metallic stents in the treatment of children with tracheomalacia and bronchomalacia in whom conventional therapy has failed. Retrospective case series. Tertiary pediatric otolaryngology and cardiothoracic surgery referral center. Six patients were identified as having undergone bronchoscopic placement of metallic balloon-expandable stents between 1994 and 1997. The age at stent placement, prior surgical interventions, and indications for and sites of stent placement were noted. Also, the complications related to stent placement and the current airway status of the patients were reviewed. Twelve balloon-expandable metallic angioplasty stents (Palmaz; Johnson & Johnson Interventional Systems Co, Warren, NJ) were placed bronchoscopically in 6 patients. Six stents were placed in the lower trachea, and 6 were placed in the main bronchi. The stents were balloon expanded under fluoroscopic guidance. Discontinuation of mechanical ventilation. The age at stent placement ranged from 1.5 to 38 months (mean age at placement, 10 months). The indications for stent placement were (1) tracheomalacia or bronchomalacia, (2) pericardial patch or slide tracheoplasty failure, and (3) bronchomalacia caused by tetralogy of Fallot and large pulmonary arteries. The primary complication of stent placement was postoperative granulation tissue formation. One patient required the removal of 2 tracheal stents because of granulation tissue formation. There were 2 deaths in the series, 1 possibly related to stent placement. Four of the 6 patients were weaned from mechanical ventilation, and 3 experienced prolonged relief of airway obstruction. Metallic balloon-expandable stents are effective in relieving lower tracheomalacia and bronchomalacia in select patients. Only patients in whom conventional therapy has failed should be considered for stent placement.

  19. Plasmonics-enabled metal-semiconductor-metal photodiodes for high-speed interconnects and polarization sensitive detectors

    NASA Astrophysics Data System (ADS)

    Panchenko, Evgeniy; Cadusch, Jasper J.; James, Timothy D.; Roberts, Ann

    2017-02-01

    Metal-semiconductor-metal (MSM) photodiodes are commonly used in ultrafast photoelectronic devices. Recently it was shown that localized surface plasmons can sufficiently enhance photodetector capabilities at both infrared and visible wavelengths. Such structures are of great interest since they can be used for fast, broadband detection. By utilizing the properties of plasmonic structures it is possible to design photodetectors that are sensitive to the polarization state of the incident wave. The direct electrical readout of the polarization state of an incident optical beam has many important applications, especially in telecommunications, bio-imaging and photonic computing. Furthermore, the fact that surface plasmon polaritons can circumvent the diffraction limit, opens up significant opportunities to use them to guide signals between logic gates in modern integrated circuits where small dimensions are highly desirable. Here we demonstrate two MSM photodetectors integrated with aluminum nanoantennas capable of distinguishing orthogonal states of either linearly or circularly polarized light with no additional filters. The localized plasmon resonances of the antennas lead to selective screening of the underlying silicon from light with a particular polarization state. The non-null response of the devices to each of the basis states expands the potential utility of the photodetectors while improving precision. We also demonstrate a design of waveguide-coupled MSM photodetector suitable for planar detection of surface plasmons.

  20. Zinc complexes developed as metallopharmaceutics for treating diabetes mellitus based on the bio-medicinal inorganic chemistry.

    PubMed

    Yoshikawa, Yutaka; Yasui, Hiroyuki

    2012-01-01

    Biological trace metals such as iron, zinc, copper, and manganese are essential to life and health of humans, and the success of platinum drugs in the cancer chemotherapy has rapidly grown interest in developing inorganic pharmaceutical agents in medicinal chemistry, that is, medicinal inorganic chemistry, using essential elements and other biological trace metals. Transition metal complexes with unique chemical structures may be useful alternatives to the drugs available to address some of the incurable diseases. In this review, we emphasize that metal complexes are an expanding of interest in the research field of treatment of diabetes mellitus. Especially, orally active anti-diabetic and anti-metabolic syndrome zinc complexes have been developed and progressed since the discovery in 2001, where several highly potent anti-diabetic zinc complexes with different coordination structures have quite recently been disclosed, using experimental diabetic animals. In all of the complexes discussed, zinc is found to be biologically active and function by interacting with some target proteins related with diabetes mellitus. The design and screening of zinc complexes with higher activity is not efficient without consideration of the translational research. For the development of a clinically useful metallopharmaceutics, the research of zinc complexes on the long-term toxicity including side effects, clear-cut evidence of target molecule for the in vivo pharmacological action, and good pharmacokinetic property are essential in the current and future studies.

  1. Efficacy of laser photoablative therapy and expandable metal stents for esophageal carcinoma

    NASA Astrophysics Data System (ADS)

    Balachandar, Gowra; Trowers, Eugene A.

    2000-05-01

    Malignant dysphagia is a serious condition in which 70% of patients die within one year, regardless of the treatment received. It provokes a rapid deterioration of a patient's physical condition and a significant worsening of quality of life. The surgical treatment of dysphagia is frequently complicated with technical difficulties, and often the tumors cannot be excised because of extensive invasion into adjacent structures. Furthermore, many patients are considered inoperable due to advanced age, associated diseases and malnutrition. Laser photoablative therapy coupled with expandable metal stents restores luminal patency in more than 80% of patients allowing them to eat liquids and soft foods. The efficacy of laser photoablative therapy and expandable metal stents for the palliation esophageal carcinoma will be critically reviewed.

  2. Metal Electrodeposition on an Integrated, Screen-Printed Electrode Assembly

    ERIC Educational Resources Information Center

    Chyan, Yieu; Chyan, Oliver

    2008-01-01

    In this lab experiment, screen-printed electrode strips are used to illustrate the essential concepts of electrochemistry, giving students an opportunity to explore metal electrodeposition processes. In the past, metal electrodeposition experiments were seldom included in general chemistry labs because of the difficulty of maintaining separate…

  3. Self-Expandable Metallic Stent Placement for the Palliation of Esophageal Cancer

    PubMed Central

    2017-01-01

    Esophageal stents have been used to palliate patients with dysphagia caused by esophageal cancer. Early rigid plastic prostheses have been associated with a high risk of complications. However, with the development of self-expanding stents, it has developed into a widely accepted method for treating malignant esophageal strictures and esophagorespiratory fistulas (ERFs). The present review covers various aspects of self-expanding metallic stent placement for palliating esophageal cancer, including its types, placement procedures, indications, contraindications, complications, and some of innovations that will become available in the future. PMID:28581260

  4. High Throughput Transcriptomics: From screening to pathways

    EPA Science Inventory

    The EPA ToxCast effort has screened thousands of chemicals across hundreds of high-throughput in vitro screening assays. The project is now leveraging high-throughput transcriptomic (HTTr) technologies to substantially expand its coverage of biological pathways. The first HTTr sc...

  5. SPOT-ligand 2: improving structure-based virtual screening by binding-homology search on an expanded structural template library.

    PubMed

    Litfin, Thomas; Zhou, Yaoqi; Yang, Yuedong

    2017-04-15

    The high cost of drug discovery motivates the development of accurate virtual screening tools. Binding-homology, which takes advantage of known protein-ligand binding pairs, has emerged as a powerful discrimination technique. In order to exploit all available binding data, modelled structures of ligand-binding sequences may be used to create an expanded structural binding template library. SPOT-Ligand 2 has demonstrated significantly improved screening performance over its previous version by expanding the template library 15 times over the previous one. It also performed better than or similar to other binding-homology approaches on the DUD and DUD-E benchmarks. The server is available online at http://sparks-lab.org . yaoqi.zhou@griffith.edu.au or yuedong.yang@griffith.edu.au. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  6. DEVELOPMENT OF THE METAL FINISHING FACILITY RISK SCREENING TOOL (MFFRST)

    EPA Science Inventory

    Recently the US EPA completed the development of the first version of the Metal Finishing Facility Risk Screening Tool (MFFRST) and has made this product available to the general public. MFFRST calculates the air emissions from a metal plating line and determines the risk to bot...

  7. Self-expandable metal stents for malignant colonic obstruction: data from a retrospective regional SIED-AIGO study.

    PubMed

    Di Mitri, Roberto; Mocciaro, Filippo; Traina, Mario; Montalbano, Luigi Maria; Familiari, Luigi; D'Amore, Fabio; Raimondo, Dario; Virgilio, Clara; Tarantino, Ilaria; Barresi, Luca; Giunta, Marco; Borina, Eleonora; Borruto, Antonino; Marino, Antonino

    2014-03-01

    Self-expandable metal stents are a non-surgical option for the treatment of symptomatic malignant colorectal obstruction as palliative treatment or as a bridge to surgery. To report data from a regional study on self-expandable metal stent (SEMS) placement for malignant colorectal obstruction. Two hundred and four patients (male 54.9%, mean age of 69.5 ± 14.2) were retrospectively evaluated and data on technical and clinical success, and complications, were analyzed. Technical and clinical success rates were 99% and 94.6% respectively, with 36.7% treated on an emergency basis and 63.3% electively. Palliative treatment was administered to 70.1%, and as a bridge to surgery for 29.9%. Complications were 17 neoplastic ingrowths, 10 stent migrations, and 4 perforations. Palliative treatment was associated with a higher risk of stent ingrowth (p=0.003), and chemotherapy with a lower risk of stent ingrowth (p=0.009). This regional study, although it has certain limitations, confirms the positive role of self-expandable metal stents in the treatment of symptomatic malignant colorectal obstruction, and that chemotherapy decreases the risk of ingrowth. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  8. Feasibility of using bulk metallic glass for self-expandable stent applications.

    PubMed

    Praveen Kumar, Gideon; Jafary-Zadeh, Mehdi; Tavakoli, Rouhollah; Cui, Fangsen

    2017-10-01

    Self-expandable stents are widely used to restore blood flow in a diseased artery segment by keeping the artery open after angioplasty. Despite the prevalent use of conventional crystalline metallic alloys, for example, nitinol, to construct self-expandable stents, new biomaterials such as bulk metallic glasses (BMGs) are being actively pursued to improve stent performance. Here, we conducted a series of analyses including finite element analysis and molecular dynamics simulations to investigate the feasibility of using a prototypical Zr-based BMG for self-expandable stent applications. We model stent crimping of several designs for different percutaneous applications. Our results indicate that BMG-based stents with diamond-shaped crowns suffer from severe localization of plastic deformation and abrupt failure during crimping. As a possible solution, we further illustrate that such abrupt failure could be avoided in BMG-based stents without diamond shape crowns. This work would open a new horizon for a quest toward exploiting superior mechanical and functional properties of metallic glasses to design future stents. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1874-1882, 2017. © 2016 Wiley Periodicals, Inc.

  9. Treatment of congenital tracheal stenosis by balloon-expandable metallic stents in paediatric intensive care unit

    PubMed Central

    Xu, Xuan; Li, Dandan; Zhao, Shuyu; Liu, Xicheng; Feng, Zhichun; Ding, Hui

    2012-01-01

    The aim of this study was to evaluate the use of balloon-expandable metallic stents in the treatment of children with congenital tracheal stenosis in whom conventional therapy has failed. From 2010 to 2011, balloon-expandable metallic stents were implanted into the trachea of eight infants aged 2–20 months in the paediatric intensive care unit. The infants had severe airway obstruction caused by congenital tracheal stenosis. Tracheal stents were placed after intraluminal balloon dilatation of the tracheal stenosis, inserted with balloon catheters and implanted into the desired position bronchoscopically. The stents were 12 to 29 mm long and 4 mm in diameter. Seven children were relieved of airway obstruction after this procedure. However, a child died due to severe sepsis after the placement of bronchial stents. No granulation tissue developed over the stents in any of the children. Stents have been in place for 1–6 months after insertion without any other complication. Balloon-expandable metallic stents are effective in relieving airway obstruction by congenital tracheal stenosis in children. This technique may provide an important remedy for congenital tracheal stenosis in children. PMID:22361127

  10. First-principles data-driven discovery of transition metal oxides for artificial photosynthesis

    NASA Astrophysics Data System (ADS)

    Yan, Qimin

    We develop a first-principles data-driven approach for rapid identification of transition metal oxide (TMO) light absorbers and photocatalysts for artificial photosynthesis using the Materials Project. Initially focusing on Cr, V, and Mn-based ternary TMOs in the database, we design a broadly-applicable multiple-layer screening workflow automating density functional theory (DFT) and hybrid functional calculations of bulk and surface electronic and magnetic structures. We further assess the electrochemical stability of TMOs in aqueous environments from computed Pourbaix diagrams. Several promising earth-abundant low band-gap TMO compounds with desirable band edge energies and electrochemical stability are identified by our computational efforts and then synergistically evaluated using high-throughput synthesis and photoelectrochemical screening techniques by our experimental collaborators at Caltech. Our joint theory-experiment effort has successfully identified new earth-abundant copper and manganese vanadate complex oxides that meet highly demanding requirements for photoanodes, substantially expanding the known space of such materials. By integrating theory and experiment, we validate our approach and develop important new insights into structure-property relationships for TMOs for oxygen evolution photocatalysts, paving the way for use of first-principles data-driven techniques in future applications. This work is supported by the Materials Project Predictive Modeling Center and the Joint Center for Artificial Photosynthesis through the U.S. Department of Energy, Office of Basic Energy Sciences, Materials Sciences and Engineering Division, under Contract No. DE-AC02-05CH11231. Computational resources also provided by the Department of Energy through the National Energy Supercomputing Center.

  11. Tracheal obstruction caused by an expandable metallic stent: a case of successful removal of the stent.

    PubMed

    Okuyama, Hiroomi; Kubota, Akio; Kawahara, Hisayoshi; Oue, Takaharu; Nose, Satoko; Ihara, Toshiyuki

    2005-07-01

    We report a case of tracheal obstruction caused by an expandable metallic stent. A 3-month-old girl with severe tracheomalacia had a placement of a Palmaz stent. At 3 years of age, she developed progressive dyspnea. The CT scan showed tracheal obstruction caused by granulation tissue over the stent. At operation, the stent was found to have penetrated the posterior tracheal wall. Under partial cardiopulmonary bypass, the stent was removed along with the membranous wall of the trachea, and the trachea was reconstructed using slide tracheoplasty. Tracheal obstruction is one of the serious complications caused by an expandable metallic stent. Direct open approach to the trachea under cardiopulmonary bypass is thought to be a safe way to manage this problem.

  12. 20180311 - High Throughput Transcriptomics: From screening to pathways (SOT 2018)

    EPA Science Inventory

    The EPA ToxCast effort has screened thousands of chemicals across hundreds of high-throughput in vitro screening assays. The project is now leveraging high-throughput transcriptomic (HTTr) technologies to substantially expand its coverage of biological pathways. The first HTTr sc...

  13. [Maternal and neonatal vitamin B12 deficiency detected by expanded newborn screening].

    PubMed

    Papp, Ferenc; Rácz, Gábor; Lénárt, István; Kóbor, Jenő; Bereczki, Csaba; Karg, Eszter; Baráth, Ákos

    2017-12-01

    Infant vitamin B 12 deficiency can manifest as a severe neurodegenerative disorder and is usually caused by maternal deficiency due to vegetarian diet or pernicious anaemia. Its early recognition and treatment can prevent potentially serious and irreversible neurologic damage. Biochemically, vitamin B 12 deficiency leads to an accumulation of methylmalonic acid, homocysteine, and propionylcarnitine. Expanded newborn screening using tandem mass spectrometry may identify neonatal and maternal vitamin B 12 deficiency by measurement of propionylcarnitine and other metabolites in the dried blood spot sample of newborns. To summarize our experiences gained by screening for vitamin B 12 deficiency. Clinical and laboratory data of vitamin B 12 -deficient infants diagnosed in Szeged Screening Centre were retrospectively analysed. In Hungary, expanded newborn screening was introduced in 2007. Since then approximately 395 000 newborns were screened in our centre and among them, we identified four newborns with vitamin B 12 deficiency based on their screening results. In three cases an elevated propionylcarnitine level and in the fourth one a low methionine level were indicative of vitamin B 12 deficiency. We also detected an additional vitamin B 12 -deficient infant with neurological symptoms at 4 months of age, after a normal newborn screening, because of elevated urinary methylmalonic acid concentration. Vitamin B 12 deficiency was secondary to maternal autoimmune pernicious anaemia in all the five infants. As a result of the recognized cases the incidence of infant vitamin B 12 deficiency in the East-Hungarian region was 1.26/100 000 births, but the real frequency may be higher. Conslusions: Optimizing the cut off values of current screening parameters and measuring of methylmalonic acid and/or homocysteine in the dried blood spot, as a second tier test, can improve recognition rate of vitamin B 12 deficiency. Orv Hetil. 2017; 158(48): 1909-1918.

  14. Expanding Cervical Cancer Screening and Treatment in Tanzania: Stakeholders’ Perceptions of Structural Influences on Scale-Up

    PubMed Central

    Giattas, Mary Rose; Sahasrabuddhe, Vikrant V.; Jolly, Pauline E.; Martin, Michelle Y.; Usdan, Stuart Lawrence; Kohler, Connie; Lisovicz, Nedra

    2015-01-01

    Tanzania has the highest burden of cervical cancer in East Africa. This study aims to identify perceived barriers and facilitators that influence scale-up of regional and population-level cervical cancer screening and treatment programs in Tanzania. Convenience sampling was used to select participants for this qualitative study among 35 key informants. Twenty-eight stakeholders from public-sector health facilities, academia, government, and nongovernmental organizations completed in-depth interviews, and a seven-member municipal health management team participated in a focus group discussion. The investigation identified themes related to the infrastructure of health services for cervical cancer prevention, service delivery, political will, and sociocultural influences on screening and treatment. Decentralizing service delivery, improving access to screening and treatment, increasing the number of trained health workers, and garnering political will were perceived as key facilitators for enhancing and initiating screening and treatment services. In conclusion, participants perceived that system-level structural factors should be addressed to expand regional and population-level service delivery of screening and treatment. Implications for Practice: Tanzanian women have a high burden of cervical cancer. Understanding the perceived structural factors that may influence screening coverage for cervical cancer and availability of treatment may be beneficial for program scale-up. This study showed that multiple factors contribute to the challenge of cervical cancer screening and treatment in Tanzania. In addition, it highlighted systematic developments aimed at expanding services. This study is important because the themes that emerged from the results may help inform programs that plan to improve screening and treatment in Tanzania and potentially in other areas with high burdens of cervical cancer. PMID:25926351

  15. Screening of sunflower cultivars for metal phytoextraction in a contaminated field prior to mutagenesis.

    PubMed

    Nehnevajova, Erika; Herzig, Rolf; Federer, Guido; Erismann, Karl-Hans; Schwitzguébel, Jean-Paul

    2005-01-01

    Sunflower can be used for the remediation of metal-contaminated soils. Its high biomass production makes this plant species interestingfor phytoextraction and using sunflower oil for a technical purpose may improve the economic balance of phytoremediation. The aim of the present field study was to screen 15 commercial cultivars of Helianthus annuus L. grown on metal-contaminated soil, to find out the variety with the highest metal extraction, which can be further improved by mutation or in vitro breeding procedures. Two different fertilizers (ammonium sulphate and ammonium nitrate) were also used to enhance the bioavailability of metals in soil Highly significant differences were observed within tested varieties for metal accumulation and extraction efficiency. Furthermore, ammonium nitrate increased cadmium extraction, whereas ammonium sulphate enhanced zinc and lead uptake in most tested cultivars. In this field-based sunflower screening, we found enhanced cumulative Cd, Zn, and Pb extraction efficiency by a factor 4.4 for Salut cultivar. We therefore emphasize that prior to any classical breeding or genetic engineering enhancing metal uptake potential, a careful screening of various genotypes should be done to select the cultivar with the naturally highest metal uptake and to start the genetic improvement with the best available plant material.

  16. Hepatitis B Screening in Asian and Pacific Islanders: New Guidelines, Old Barriers.

    PubMed

    Nguyen, Cathina T; Lin, Steven Y

    2015-10-01

    Chronic hepatitis B virus (HBV) infection is a serious liver disease that disproportionately affects Asian and Pacific Islander immigrants. In May 2014, the U.S. Preventive Services Task Force released new HBV screening guidelines that expanded screening to non-pregnant adolescents and adults who were born in Asia and the Pacific Islands, and U.S.-born persons not vaccinated as infants whose parents were born in Central or Southeast Asia. Although the guidelines empower health care providers and community health workers to expand their screening efforts, old barriers to screening remain deeply rooted in this population. These barriers include cultural beliefs about wellness, myths and misconceptions about HBV, and lack of access to appropriate, culturally sensitive care. Through a combination of strategies--retooling the current health care workforce to be more culturally sensitive providers, involving oriental medicine practitioners in patient education, and engaging grassroots organizations--we can overcome barriers and take full advantage of the new HBV screening guidelines.

  17. Self-Expandable Metallic Stent Placement for the Palliation of Esophageal Cancer.

    PubMed

    Kim, Kun Yung; Tsauo, Jiaywei; Song, Ho Young; Kim, Pyeong Hwa; Park, Jung Hoon

    2017-07-01

    Esophageal stents have been used to palliate patients with dysphagia caused by esophageal cancer. Early rigid plastic prostheses have been associated with a high risk of complications. However, with the development of self-expanding stents, it has developed into a widely accepted method for treating malignant esophageal strictures and esophagorespiratory fistulas (ERFs). The present review covers various aspects of self-expanding metallic stent placement for palliating esophageal cancer, including its types, placement procedures, indications, contraindications, complications, and some of innovations that will become available in the future. © 2017 The Korean Academy of Medical Sciences.

  18. Electrostatic interactions between ions near Thomas-Fermi substrates and the surface energy of ionic crystal at imperfect metals

    PubMed Central

    Kaiser, V.; Comtet, J.; Niguès, A.; Siria, A.; Coasne, B.; Bocquet, L.

    2017-01-01

    The electrostatic interaction between two charged particles is strongly modified in the vicinity of a metal. This situation is usually accounted for by the celebrated image charges approach, which was further extended to account for the electronic screening properties of the metal at the level of the Thomas-Fermi description. In this paper we build upon the approach by [Kornyshev et al. Zh. Eksp. Teor. Fiz., 78(3):1008–1019, 1980] and successive works to calculate the 1-body and 2-body electrostatic energy of ions near a metal in terms of the Thomas-Fermi screening length. We propose workable approximations suitable for molecular simulations of ionic systems close to metallic walls. Furthermore, we use this framework to calculate analytically the electrostatic contribution to the surface energy of a one dimensional crystal at a metallic wall and its dependence on the Thomas-Fermi screening length. These calculations provide a simple interpretation for the surface energy in terms of image charges, which allow for an estimate of interfacial properties in more complex situations of a disordered ionic liquid close to a metal surface. A counterintuitive outcome is that electronic screening, as characterized by a molecular Thomas-Fermi length ℓTF, profoundly affects the wetting of ionic systems close to a metal, in line with the recent experimental observation of capillary freezing of ionic liquids in metallic confinement. PMID:28436506

  19. Biochemical and molecular diagnosis of tyrosinemia type I with two novel FAH mutations in a Hong Kong chinese patient: recommendation for expanded newborn screening in Hong Kong.

    PubMed

    Mak, Chloe Miu; Lam, Ching-Wan; Chim, Stella; Siu, Tak-Shing; Ng, King-Fai; Tam, Sidney

    2013-01-01

    Tyrosinemia type I is an autosomal recessive disorder in tyrosine metabolism. In areas without expanded newborn screening, patients present with acute hepatorenal failure in early infancy. Diagnosis can be elusive when clinical presentation is non-specific and biochemical abnormalities are masked by secondary changes. This is the first Hong Kong Chinese report. A two-month-old Chinese male infant with unremarkable antenatal and postnatal history presented with progressive abdominal distension for three days. He suffered from end-stage liver failure, hypoglycemia and hepatic encephalopathy. Diagnostic work-up was complicated starting from rule-out sepsis, intestinal obstruction, volvulus, peritonitis, septic ileus, poisoning to metabolic diseases. Clinical, biochemical and genetic data was described. The patient showed increases in multiple plasma amino acids including tyrosine, phenylalanine and methionine, and hyper-excretions of 4-hydroxyphenyl-acetate, -pyruvate, and -lactate, as well as N-acetyltyrosine which could be seen in liver failure due to both tyrosinemia type I and non-metabolic conditions. Because of the volatile nature, succinylacetone was almost undetectable. The diagnosis was confirmed by genetic analysis of FAH with two novel mutations, viz. NM_000137.2:c.1063-1G>A and NM_000137.2:c.1035_1037del. Living-related liver transplantation was done. However, the patient still suffered many complications after the severe metabolic insult with hypoxic ischemic encephalopathy, cerebral atrophy, global developmental delay and cortical visual impairment. Because of the lack of expanded newborn screening in Hong Kong, this child unfortunately presented in the most severe form of tyrosinemia type I. Expanded newborn screening can save life and reduce the burden of diagnostic complexity. This illustrates the need for expanded newborn screening in Hong Kong. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Pregnant Women's Perspectives on Expanded Carrier Screening.

    PubMed

    Propst, Lauren; Connor, Gwendolyn; Hinton, Megan; Poorvu, Tabitha; Dungan, Jeffrey

    2018-02-23

    Expanded carrier screening (ECS) is a relatively new carrier screening option that assesses many conditions simultaneously, as opposed to traditional ethnicity-based carrier screening for a limited number of conditions. This study aimed to explore pregnant women's perspectives on ECS, including reasons for electing or declining and anxiety associated with this decision-making. A total of 80 pregnant women were surveyed from Northwestern Medicine's Clinical Genetics Division after presenting for aneuploidy screening. Of the 80 participants, 40 elected and 40 declined ECS. Trends regarding reasons for electing or declining ECS include ethnicity, desire for genetic risk information, lack of family history, perceived likelihood of being a carrier, and perceived impact on reproductive decisions. Individuals who declined ECS seemed to prefer ethnicity-based carrier screening and believed that ECS would increase their anxiety, whereas individuals who elected ECS seemed to prefer more screening and tended to believe that ECS would reduce their anxiety. These findings provide insight on decision-making with regard to ECS and can help guide interactions that genetic counselors and other healthcare providers have with patients, including assisting patients in the decision-making process.

  1. Hepatitis C screening trends in a large integrated health system

    PubMed Central

    Linas, Benjamin P.; Hu, Haihong; Barter, Devra M.; Horberg, Michael

    2014-01-01

    Background As new hepatitis C virus (HCV) therapies emerge, only 1–12% of individuals are screened in the U.S. for HCV infection. Presently, HCV screening trends are unknown. Methods We utilized the Kaiser Permanente Mid-Atlantic States’ (KPMAS) data repository to investigate HCV antibody screening between 1/1/2003 and 12/31/2012. We identified the proportion screened for HCV and 5-year cumulative incidence of screening, the screening positivity rate, the provider types performing HCV screening, patient-level factors associated with being screened, and trends in screening over time. Results 444,594 patients met the inclusion criteria. Overall, 15.8% of the cohort was ever screened for HCV. Adult primary care and obstetrics and gynecology providers performed 75.9% of all screening. The overall test positivity rate was 3.8%. Screening was more frequent in younger age groups (p<0.0001) and those with a documented history of illicit drug use (p<0.0001). Patients with missing drug use history (46.7%) were least likely to be screened (p<0.0001). While the rate of HCV screening increased in the later years of the study, among those enrolled in KPMAS 2009–2012, only 11.8% were screened by the end of follow-up. Conclusion Screening for HCV is increasing, but remains incomplete. Targeting screening to those with a history of injection drug will not likely expand screening, as nearly half of patients have no documented drug use history. Routine screening is likely the most effective approach to expand HCV screening. PMID:24486288

  2. Hepatitis C screening trends in a large integrated health system.

    PubMed

    Linas, Benjamin P; Hu, Haihong; Barter, Devra M; Horberg, Michael

    2014-05-01

    As new hepatitis C virus (HCV) therapies emerge, only 1%-12% of individuals are screened in the US for HCV infection. Presently, HCV screening trends are unknown. We utilized the Kaiser Permanente Mid-Atlantic States' (KPMAS) data repository to investigate HCV antibody screening between January 1, 2003 and December 31, 2012. We identified the proportion screened for HCV and 5-year cumulative incidence of screening, the screening positivity rate, the provider types performing HCV screening, patient-level factors associated with being screened, and trends in screening over time. There were 444,594 patients who met the inclusion criteria. Overall, 15.8% of the cohort was ever screened for HCV. Adult primary care and obstetrics and gynecology providers performed 75.9% of all screening. The overall test positivity rate was 3.8%. Screening was more frequent in younger age groups (P <.0001) and those with a documented history of illicit drug use (P <.0001). Patients with missing drug use history (46.7%) were least likely to be screened (P <.0001). While the rate of HCV screening increased in the later years of the study among those enrolled in KPMAS 2009-2012, only 11.8% were screened by the end of follow-up. Screening for HCV is increasing but remains incomplete. Targeting screening to those with a history of injection drug will not likely expand screening, as nearly half of patients have no documented drug use history. Routine screening is likely the most effective approach to expand HCV screening. Copyright © 2014. Published by Elsevier Inc.

  3. Screen-Printed Electrodes Modified with “Green” Metals for Electrochemical Stripping Analysis of Toxic Elements

    PubMed Central

    Economou, Anastasios

    2018-01-01

    This work reviews the field of screen-printed electrodes (SPEs) modified with “green” metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of “green” metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques) are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned. PMID:29596391

  4. Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.

    PubMed

    Economou, Anastasios

    2018-03-29

    This work reviews the field of screen-printed electrodes (SPEs) modified with "green" metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of "green" metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques) are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned.

  5. Unique usage of a partially covered metal stent for drainage of a pancreatic pseudocyst via endosonography-guided transcystgastrostomy.

    PubMed

    Nici, Anthony J; Hussain, Syed A; Kim, Sang H; Mehta, Preeti

    2012-05-01

    Pancreatic pseudocysts are frequent complications of pancreatitis episodes. The current therapeutic modalities for drainage of pancreatic pseudocysts include surgical, percutaneous, and endoscopic drainage modalities. Endosonography-assisted endoscopic drainage of these pseudocysts with the placement of multiple plastic or fully covered self-expanding biliary metal stents is becoming more commonly carried out. The present case report discusses the unique and successful drainage of a pancreatic pseudocyst with the placement of a partially covered self-expanding metal stent. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  6. Screening Technique for Lead and Cadmium in Toys and Other Materials Using Atomic Absorption Spectroscopy

    ERIC Educational Resources Information Center

    Brouwer, Henry

    2005-01-01

    A simple procedure to quickly screen different consumer products for the presence of lead, cadmium, and other metals is described. This screening technique avoids expending a lot of preparation time on samples known to contain low levels of hazardous metals where only samples testing positive for the desired elements need to be analyzed…

  7. [Expand newborn screening using tandem mass spectrometry: two years' experience in Nuevo León, Mexico].

    PubMed

    Torres-Sepúlveda, María del Rosario; Martínez-de Villarreal, Laura E; Esmer, Carmen; González-Alanís, Rogerio; Ruiz-Herrera, Consuelo; Sánchez-Peña, Alejandra; Mendoza-Cruz, José Alberto; Villarreal-Pérez, Jesús Z

    2008-01-01

    To initiate a statewide expanded metabolic screening program in neonates with the purpose of identifying the most common inborn errors of metabolism. From March 2002 through February 2004, a blood sample was obtained between 24 and 48 hours after delivery from every consecutive child born in public hospitals in Nuevo León. It was spotted on filter paper and analyzed by tandem mass spectrometry for expanded metabolic screening. A total of 42 264 samples were analyzed. Were obtained seven positive results, one for each disorder: homocystinuria, hyperphenylalaninemia, citrulinemia, transient tyrosinemia, 3-methylcrotonyl CoA carboxylase deficiency, 3-hydroxy-3-methylglutaryl CoA deficiency, and classic galactosemia. The estimated incidence of inborn errors of metabolism is 1:5 000, with a false positive rate of 0.22%. The program permitted the identification of metabolic disorders in the newborn, allowing an early intervention and prevention of life-threatening events and permanent neurological damage.

  8. Electrostatic interactions between ions near Thomas-Fermi substrates and the surface energy of ionic crystals at imperfect metals.

    PubMed

    Kaiser, V; Comtet, J; Niguès, A; Siria, A; Coasne, B; Bocquet, L

    2017-07-01

    The electrostatic interaction between two charged particles is strongly modified in the vicinity of a metal. This situation is usually accounted for by the celebrated image charges approach, which was further extended to account for the electronic screening properties of the metal at the level of the Thomas-Fermi description. In this paper we build upon a previous approach [M. A. Vorotyntsev and A. A. Kornyshev, Zh. Eksp. Teor. Fiz., 1980, 78(3), 1008-1019] and successive works to calculate the 1-body and 2-body electrostatic energy of ions near a metal in terms of the Thomas-Fermi screening length. We propose workable approximations suitable for molecular simulations of ionic systems close to metallic walls. Furthermore, we use this framework to calculate analytically the electrostatic contribution to the surface energy of a one dimensional crystal at a metallic wall and its dependence on the Thomas-Fermi screening length. These calculations provide a simple interpretation for the surface energy in terms of image charges, which allows for an estimation of the interfacial properties in more complex situations of a disordered ionic liquid close to a metal surface. The counter-intuitive outcome is that electronic screening, as characterized by a molecular Thomas-Fermi length l TF , profoundly affects the wetting of ionic systems close to a metal, in line with the recent experimental observation of capillary freezing of ionic liquids in metallic confinement.

  9. Liquid-metal-piston MHD generator

    NASA Technical Reports Server (NTRS)

    Palmer, J. P.

    1969-01-01

    Magnetohydrodynamic generator uses a slug or piston of liquid potassium as the working fluid. An expanding vapor of the metal is allowed to reciprocate the liquid-metal-piston through a magnetic field and the expansion energy is converted directly into electrical energy.

  10. Successful removal of self-expanding metallic stent after deployment for tubercular bronchostenosis.

    PubMed

    Isaac, Barney Thomas Jesudason; Datey, Ashima; Christopher, Devasahayam Jesudas

    2016-01-01

    The use of metallic stents is traditionally not recommended for benign tracheobronchial conditions. With advances in the field of interventional bronchoscopy, metal tracheobronchial stents have occasionally been used to treat benign disease. However, the removal of these stents from the airway is technically difficult. We are reporting the case of a young female subject who received a self-expanding metallic stent for alleviation of post-tubercular bronchostenosis, which was successfully removed after two months without complications. Metal stents can be used in benign tracheobronchial conditions but require meticulous follow-up to monitor complications. Experienced operators can remove them without major complications and this may be life-saving in emergencies. We are reporting this case for the rarity of such procedures in India. Copyright © 2015 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhamu, Aruna; Shi, Jinjun; Guo, Jiusheng

    An electrically conductive laminate composition for fuel cell flow field plate or bipolar plate applications. The laminate composition comprises at least a thin metal sheet having two opposed exterior surfaces and a first exfoliated graphite composite sheet bonded to the first of the two exterior surfaces of the metal sheet wherein the exfoliated graphite composite sheet comprises: (a) expanded or exfoliated graphite and (b) a binder or matrix material to bond the expanded graphite for forming a cohered sheet, wherein the binder or matrix material is between 3% and 60% by weight based on the total weight of the firstmore » exfoliated graphite composite sheet. Preferably, the first exfoliated graphite composite sheet further comprises particles of non-expandable graphite or carbon in the amount of between 3% and 60% by weight based on the total weight of the non-expandable particles and the expanded graphite. Further preferably, the laminate comprises a second exfoliated graphite composite sheet bonded to the second surface of the metal sheet to form a three-layer laminate. Surface flow channels and other desired geometric features can be built onto the exterior surfaces of the laminate to form a flow field plate or bipolar plate. The resulting laminate has an exceptionally high thickness-direction conductivity and excellent resistance to gas permeation.« less

  12. Esophagojejunal Anastomosis Fistula, Distal Esophageal Stenosis, and Metalic Stent Migration after Total Gastrectomy

    PubMed Central

    Al Hajjar, Nadim; Popa, Calin; Al-Momani, Tareg; Margarit, Simona; Graur, Florin; Tantau, Marcel

    2015-01-01

    Esophagojejunal anastomosis fistula is the main complication after a total gastrectomy. To avoid a complex procedure on friable inflamed perianastomotic tissues, a coated self-expandable stent is mounted at the site of the anastomotic leak. A complication of stenting procedure is that it might lead to distal esophageal stenosis. However, another frequently encountered complication of stenting is stent migration, which is treated nonsurgically. When the migrated stent creates life threatening complications, surgical removal is indicated. We present a case of a 67-year-old male patient who was treated at our facility for a gastric adenocarcinoma which developed, postoperatively, an esophagojejunostomy fistula, a distal esophageal stenosis, and a metallic coated self-expandable stent migration. To our knowledge, this is the first reported case of an esophagojejunostomy fistula combined with a distal esophageal stenosis as well as with a metallic coated self-expandable stent migration. PMID:25945277

  13. Fluorophore Metal-Organic Complexes: High-Throughput Optical Screening for Aprotic Electrochemical Systems.

    PubMed

    Park, Sung Hyeon; Choi, Chang Hyuck; Lee, Seung Yong; Woo, Seong Ihl

    2017-02-13

    Combinatorial optical screening of aprotic electrocatalysts has not yet been achieved primarily due to H + -associated mechanisms of fluorophore modulation. We have overcome this problem by using fluorophore metal-organic complexes. In particular, eosin Y and quinine can be coordinated with various metallic cations (e.g., Li + , Na + , Mg 2+ , Zn 2+ , and Al 3+ ) in aprotic solvents, triggering changes in their fluorescent properties. These interactions have been used in a reliable screening method to determine oxygen reduction/evolution reaction activities of 100 Mn-based binary catalysts for the aprotic Li-air battery.

  14. Nationwide genetic analysis for molecularly unresolved cystic fibrosis patients in a multiethnic society: implications for preconception carrier screening.

    PubMed

    Behar, Doron M; Inbar, Ori; Shteinberg, Michal; Gur, Michal; Mussaffi, Huda; Shoseyov, David; Ashkenazi, Moshe; Alkrinawi, Soliman; Bormans, Concetta; Hakim, Fahed; Mei-Zahav, Meir; Cohen-Cymberknoh, Malena; Dagan, Adi; Prais, Dario; Sarouk, Ifat; Stafler, Patrick; Bar Aluma, Bat El; Akler, Gidon; Picard, Elie; Aviram, Micha; Efrati, Ori; Livnat, Galit; Rivlin, Joseph; Bentur, Lea; Blau, Hannah; Kerem, Eitan; Singer, Amihood

    2017-05-01

    Preconception carrier screening for cystic fibrosis (CF) is usually performed using ethnically targeted panels of selected mutations. This has been recently challenged by the use of expanded, ethnically indifferent, pan-population panels. Israel is characterized by genetically heterogeneous populations carrying a wide range of CFTR mutations. To assess the potential of expanding the current Israeli preconception screening program, we sought the subset of molecularly unresolved CF patients listed in the Israeli CF data registry comprising ~650 patients. An Israeli nationwide genotyping of 152 CF cases, representing 176 patients lacking molecular diagnosis, was conducted. Molecular analysis included Sanger sequencing for all exons and splice sites, multiplex ligation probe amplification (MLPA), and next-generation sequencing of the poly-T/TG tracts. We identified 54 different mutations, of which only 16 overlapped the 22 mutations included in the Israeli preconception screening program. A total of 29/54 (53.7%) mutations were already listed as CF causing by the CFTR2 database, and only 4/54 (7.4%) were novel. Molecular diagnosis was reached in 78/152 (51.3%) cases. Prenatal diagnosis of 24/78 (30.8%) cases could have been achieved by including all CFTR2-causing mutations in the Israeli panel. Our data reveal an overwhelming hidden abundance of CFTR gene mutations suggesting that expanded preconception carrier screening might achieve higher preconception detection rates.

  15. Universal Newborn Screening and Adverse Medical Outcomes: A Historical Note

    ERIC Educational Resources Information Center

    Brosco, Jeffrey P.; Seider, Michael I.; Dunn, Angela C.

    2006-01-01

    Universal newborn screening programs for metabolic disorders are typically described as a triumph of medicine and public policy in the US over the last 50 years. Advances in science and technology, including the Human Genome Project, offer the opportunity to expand universal newborn screening programs to include many additional metabolic and…

  16. Research of the Aerophysics Institute for the Strategic Technology Office (DARPA)

    DTIC Science & Technology

    1975-06-30

    19. (continued) 6. Unstable Optical Resonator Cavities 7. Laser Metal Screening Program 8. Ultraviolet & Blue-Green Lasers 9. Efficient Metal...Vapor Lasers 10. Atomic Transition Probabilities 11. Computer Modeling of Laser Dynamic 12. Startified Ocean Wakes L0. (continued) In the... laser area, the major task was the screening of atomic vapors, particularly metal vapors, for new, efficient lasers in the visible and ultra

  17. [Cost-effectiveness trial of self-expandable metal stents and plastic biliary stents in malignant biliary obstruction].

    PubMed

    Daróczi, Tímea; Bor, Renáta; Fábián, Anna; Szabó, Ella; Farkas, Klaudia; Bálint, Anita; Czakó, László; Rutka, Mariann; Szűcs, Mónika; Milassin, Ágnes; Molnár, Tamás; Szepes, Zoltán

    2016-02-14

    Self-expandable metal and plastic stents can be applied in the palliative endoscopic treatment of patients with unresectable malignant biliary obstruction. The use of metal stentsis recommended if the patient's life expectancy is more than four months. To compare the therapeutic efficacy and cost-effectiveness of metal and plastic stents in the treatment of malignant biliary obstruction. The authors retrospectively enrolled patients who received metal (37 patients) or plastic stent (37 patients). The complication rate, stent patency and cumulative cost of treatment were assessed in the two groups. The complication rate of metal stents was lower (37.84% vs. 56.76%), but the stent patency was higher compared with plastic stents (19.11 vs. 8.29 weeks; p = 0.0041). In the plastic stent group the frequency of hospitalization of patients in context with stent complications (1.18 vs. 2.32; p = 0.05) and the necessity of reintervention for stent dysfunction (17 vs. 27; p = 0.033) were substantially higher. In this group multiple stent implantation raised the stent patency from 7.68 to 10.75 weeks. There was no difference in the total cost of treatment of malignant biliary obstruction between the two groups (p = 0.848). Considering the cost of treatment and the burden of patients the authors recommend self-expandable metal sten timplantation if the life expectancy of patients is more than two months. In short survival cases multiple plastic stent implantation is recommended.

  18. Self-Expandable Metal Stents and Trans-stent Light Delivery: Are Metal Stents and Photodynamic Therapy Compatible?

    PubMed Central

    Wang, Luo-Wei; Li, Li-Bo; Li, Zhao-Shen; Chen, Yang K; Hetzel, Fred W.; Huang, Zheng

    2008-01-01

    Background and Objectives: Obstructive non-small cell lung cancer and obstructive esophageal cancer are US FDA approved indications of photodynamic therapy (PDT). The usefulness of PDT for the treatment of cholangiocarcinoma is currently under clinical investigation. Endoscopic stenting for lumen restoration is a common palliative intervention for those indications. It is important to assess whether self-expandable metal stents are compatible with trans-stent PDT light delivery. Study Design/Materials and Methods: Direct effects of various components of metal biliary (n = 2), esophageal (n = 2), and bronchial (n = 1) stents on PDT light transmittance and distribution were examined using a point or linear light source (630 or 652 nm diode laser). Resected pig biliary duct and esophageal wall tissues were used to examine the feasibility of PDT light delivery through the fully expanded metal stents. Results: While using a point light source, the metal components (thread and joint) of the stent could cause a significant shadow effect. The liner material (polytetrafluoroethylene or polyurethane) could cause various degrees of light absorption. When the stent was covered with a thin layer of biliary duct and esophageal tissues containing all wall layers, the shadow effect could be mitigated due to tissue scattering. Conclusions: This study clearly demonstrates that it is feasible to combine stenting and PDT for the treatment of luminal lesions. PDT light dose should be adjusted to counteract the reduction of light transmittance caused by the metal and liner materials of stent. PMID:18951422

  19. Screening, prevention and treatment of cervical cancer -- a global and regional generalized cost-effectiveness analysis.

    PubMed

    Ginsberg, Gary Michael; Edejer, Tessa Tan-Torres; Lauer, Jeremy A; Sepulveda, Cecilia

    2009-10-09

    The paper calculates regional generalized cost-effectiveness estimates of screening, prevention, treatment and combined interventions for cervical cancer. Using standardised WHO-CHOICE methodology, a cervical cancer model was employed to provide estimates of screening, vaccination and treatment effectiveness. Intervention effectiveness was determined via a population state-transition model (PopMod) that simulates the evolution of a sub-regional population accounting for births, deaths and disease epidemiology. Economic costs of procedures and treatment were estimated, including programme overhead and training costs. In regions characterized by high income, low mortality and high existing treatment coverage, the addition of any screening programme to the current high treatment levels is very cost-effective. However, based on projections of the future price per dose (representing the economic costs of the vaccination excluding monopolistic rents and vaccine development cost) vaccination is the most cost-effective intervention. In regions characterized by low income, low mortality and existing treatment coverage around 50%, expanding treatment with or without combining it with screening appears to be cost-effective or very cost-effective. Abandoning treatment in favour of screening in a no-treatment scenario would not be cost-effective. Vaccination is usually the most cost-effective intervention. Penta or tri-annual PAP smears appear to be cost-effective, though when combined with HPV-DNA testing they are not cost-effective. In regions characterized by low income, high mortality and low treatment levels, expanding treatment with or without adding screening would be very cost-effective. A one off vaccination plus expanding treatment was usually very cost-effective. One-off PAP or VIA screening at age 40 are more cost-effective than other interventions though less effective overall. From a cost-effectiveness perspective, consideration should be given to implementing vaccination (depending on cost per dose and longevity of efficacy) and screening programmes on a worldwide basis to reduce the burden of disease from cervical cancer. Treatment should also be increased where coverage is low.

  20. Impact of highway traffic and the acoustic screen on the content and spatial distribution of heavy metals in soils.

    PubMed

    Różański, Szymon; Jaworska, Hanna; Matuszczak, Katarzyna; Nowak, Joanna; Hardy, Amber

    2017-05-01

    Recent years have witnessed intensification of road traffic and, with it, the amount of substances emitted by vehicles. Such emissions need to be monitored for public health purposes. The aim of this study was to evaluate the impact of the highway traffic on the total content and bioavailability of Zn, Cu, Ni, Cd, Cr and Pb in nearby soils as well as influence of an acoustic screen on spatial distribution of the metals. The material included 40 soil samples collected from 15 research points located 5, 10, 25 and 50 m away from the road acoustic screen and from 4 points between the screen and the highway. Additionally, 5 research points were located next to the metal barrier. Selected physicochemical properties of soils were determined: soil texture, soil pH, TOC and CaCO 3 content. The total content of heavy metals in the soils was determined by AAS after digestion in aqua regia and bioavailable forms in 1 M diethylenetriaminepentaacetic acid. The research found low impact of the highway traffic on the content of heavy metals in soils; however, due to a very short period of this potential impact (5 years), the moderately polluted category of geo-accumulation index of cadmium and high bioavailability of lead indicate the need of repeating the research within the next several years. Furthermore, the road acoustic screen significantly influenced spatial distribution of the metals in soils.

  1. Protected Nuclear Fuel Element

    DOEpatents

    Kittel, J. H.; Schumar, J. F.

    1962-12-01

    A stainless steel-clad actinide metal fuel rod for use in fast reactors is reported. In order to prevert cladding failures due to alloy formation between the actinide metal and the stainless steel, a mesh-like sleeve of expanded metal is interposed between them, the sleeve metal being of niobium, tantalum, molybdenum, tungsten, zirconium, or vanadium. Liquid alkali metal is added as a heat transfer agent. (AEC)

  2. Tuberculosis screening in high human immunodeficiency virus prevalence settings: turning promise into reality

    PubMed Central

    Corbett, E. L.; MacPherson, P.

    2014-01-01

    SUMMARY Twenty years of sky-high tuberculosis (TB) incidence rates and high TB mortality in high human immunodeficiency virus (HIV) prevalence countries have so far not been matched by the same magnitude or breadth of responses as seen in malaria or HIV programmes. Instead, recommendations have been narrowly focused on people presenting to health facilities for investigation of TB symptoms, or for HIV testing and care. However, despite the recent major investment and scale-up of TB and HIV services, undiagnosed TB remains highly prevalent at community level, implying that diagnosis of TB remains slow and incomplete. This maintains high transmission rates and exposes people living with HIV to high rates of morbidity and mortality. More intensive use of TB screening, with broader definitions of target populations, expanded indications for screening both inside and outside of health facilities, and appropriate selection of new diagnostic tools, offers the prospect of rapidly improving population-level control of TB. Diagnostic accuracy of suitable (high throughput) algorithms remains the major barrier to realising this goal. In the present study, we review the evidence available to guide expanded TB screening in HIV-prevalent settings, ideally through combined TB-HIV interventions that provide screening for both TB and HIV, and maximise entry to HIV and TB care and prevention. Ideally, we would systematically test, treat and prevent TB and HIV comprehensively, offering both TB and HIV screening to all health facility attendees, TB households and all adults in the highest risk communities. However, we are still held back by inadequate diagnostics, financing and paucity of population-impact data. Relevant contemporary research showing the high need for potential gains, and pitfalls from expanded and intensified TB screening in high HIV prevalence settings are discussed in this review. PMID:23928165

  3. Resistance of Metallic Screens in a Cryogenic Flow

    NASA Astrophysics Data System (ADS)

    Fischer, Alexander; Stief, Malte

    The propellant behaviour in cryogenic upper stages tanks imposes challenging requirements on the design, especially for future upper stages designed for multiple restarts and long ballistic flight phases. The main challenge is the supply of the propellants to the feed system prior to the engine reignition. During the entire mission the engine requires a gaseous and bubble free liquid supply of propellant at the required thermodynamic conditions. The current research focus is to prepare the initial steps for the maturation of the Propellant Management Device (PMD) technology for cryogenic tank systems. Main components of such a PMD are metallic screens. The metallic screens are used as barrier for any gas bubbles within the fluid stream approaching the space craft engines. The screen characteristics are of fundamental importance for the PMD and feed system design. The paper presents a summary on available experimental screen data with regard to the flow resistance and gives a comparison with theoretical and empirical predictions found in literature. The lack on comparable data with regard to space craft applications and the need on further research with cryogenic flows is demonstrated. The DLR Institute of Space Systems is preparing various cryogenic tests to collect the desired information about the flow properties of such metallic screens. The planned test setup and the foreseen experiments will be presented.

  4. Screening and transport in 2D semiconductor systems at low temperatures

    PubMed Central

    Das Sarma, S.; Hwang, E. H.

    2015-01-01

    Low temperature carrier transport properties in 2D semiconductor systems can be theoretically well-understood within RPA-Boltzmann theory as being limited by scattering from screened Coulomb disorder arising from random quenched charged impurities in the environment. In this work, we derive a number of analytical formula, supported by realistic numerical calculations, for the relevant density, mobility, and temperature range where 2D transport should manifest strong intrinsic (i.e., arising purely from electronic effects) metallic temperature dependence in different semiconductor materials arising entirely from the 2D screening properties, thus providing an explanation for why the strong temperature dependence of the 2D resistivity can only be observed in high-quality and low-disorder 2D samples and also why some high-quality 2D materials manifest much weaker metallicity than other materials. We also discuss effects of interaction and disorder on the 2D screening properties in this context as well as compare 2D and 3D screening functions to comment why such a strong intrinsic temperature dependence arising from screening cannot occur in 3D metallic carrier transport. Experimentally verifiable predictions are made about the quantitative magnitude of the maximum possible low-temperature metallicity in 2D systems and the scaling behavior of the temperature scale controlling the quantum to classical crossover. PMID:26572738

  5. Modeling blur in various detector geometries for MeV radiography

    NASA Astrophysics Data System (ADS)

    Winch, Nicola M.; Watson, Scott A.; Hunter, James F.

    2017-03-01

    Monte Carlo transport codes have been used to model the detector blur and energy deposition in various detector geometries for applications in MeV radiography. Segmented scintillating detectors, where low Z scintillators combined with a high-Z metal matrix, can be designed in which the resolution increases with increasing metal fraction. The combination of various types of metal intensification screens and storage phosphor imaging plates has also been studied. A storage phosphor coated directly onto a metal intensification screen has superior performance over a commercial plate. Stacks of storage phosphor plates and tantalum intensification screens show an increase in energy deposited and detective quantum efficiency with increasing plate number, at the expense of resolution. Select detector geometries were tested by comparing simulation and experimental modulation transfer functions to validate the approach.

  6. Prosthetic metal implants and airport metal detectors.

    PubMed

    Ismail, A; Dancey, A; Titley, O G

    2013-04-01

    Metal detectors have been present in airports and points of departure for some time. With the introduction of heightened security measures in response to fears of an increased threat of terrorism, they may become more prevalent in other public locations. The aim of this study was to ascertain which prosthetic devices activated metal detector devices used for security purposes. A range of prosthetic devices used commonly in orthopaedic and plastic surgery procedures were passed through an arch metal detector at Birmingham Airport in the UK. Additionally, each item was passed under a wand detector. Items tested included expandable breast prostheses, plates used in wrist and hand surgery, screws, K-wires, Autosuture™ ligation clips and staples. No prostheses were detected by the arch detector. The expandable implants and wrist plates were the only devices detected by passing the wand directly over them. No device was detected by the wand when it was under cover of the axillary soft tissue. Screws, K-wires, Autosuture™ clips and staples were not detected under any of the study conditions. Although unlikely to trigger a detector, it is possible that an expandable breast prosthesis or larger plate may do so. It is therefore best to warn patients of this so they can anticipate detection and further examination.

  7. Prosthetic metal implants and airport metal detectors

    PubMed Central

    Dancey, A; Titley, OG

    2013-01-01

    Introduction Metal detectors have been present in airports and points of departure for some time. With the introduction of heightened security measures in response to fears of an increased threat of terrorism, they may become more prevalent in other public locations. The aim of this study was to ascertain which prosthetic devices activated metal detector devices used for security purposes. Methods A range of prosthetic devices used commonly in orthopaedic and plastic surgery procedures were passed through an arch metal detector at Birmingham Airport in the UK. Additionally, each item was passed under a wand detector. Items tested included expandable breast prostheses, plates used in wrist and hand surgery, screws, K-wires, Autosuture™ ligation clips and staples. Results No prostheses were detected by the arch detector. The expandable implants and wrist plates were the only devices detected by passing the wand directly over them. No device was detected by the wand when it was under cover of the axillary soft tissue. Screws, K-wires, Autosuture™ clips and staples were not detected under any of the study conditions. Conclusions Although unlikely to trigger a detector, it is possible that an expandable breast prosthesis or larger plate may do so. It is therefore best to warn patients of this so they can anticipate detection and further examination. PMID:23827294

  8. Method of handling radioactive alkali metal waste

    DOEpatents

    Wolson, Raymond D.; McPheeters, Charles C.

    1980-01-01

    Radioactive alkali metal is mixed with particulate silica in a rotary drum reactor in which the alkali metal is converted to the monoxide during rotation of the reactor to produce particulate silica coated with the alkali metal monoxide suitable as a feed material to make a glass for storing radioactive material. Silica particles, the majority of which pass through a 95 mesh screen or preferably through a 200 mesh screen, are employed in this process, and the preferred weight ratio of silica to alkali metal is 7 to 1 in order to produce a feed material for the final glass product having a silica to alkali metal monoxide ratio of about 5 to 1.

  9. Method of handling radioactive alkali metal waste

    DOEpatents

    Wolson, R.D.; McPheeters, C.C.

    Radioactive alkali metal is mixed with particulate silica in a rotary drum reactor in which the alkali metal is converted to the monoxide during rotation of the reactor to produce particulate silica coated with the alkali metal monoxide suitable as a feed material to make a glass for storing radioactive material. Silica particles, the majority of which pass through a 95 mesh screen or preferably through a 200 mesh screen, are employed in this process, and the preferred weight ratio of silica to alkali metal is 7 to 1 in order to produce a feed material for the final glass product having a silica to alkali metal monoxide ratio of about 5 to 1.

  10. Clinical Outcomes of Self-Expandable Metal Stents for Malignant Rectal Obstruction.

    PubMed

    Lee, Hyun Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Tae Il; Kim, Won Ho; Park, Soo Jung

    2018-01-01

    Self-expandable metal stents are widely used to treat malignant colorectal obstruction. However, data on clinical outcomes of stent placement for rectal obstruction specifically are lacking. We aimed to investigate the clinical outcomes of self-expandable metal stents in malignant rectal obstruction in comparison with those in left colonic obstruction and to identify factors associated with clinical failure and complication. This was a retrospective study. The study was conducted at a tertiary care center. Between January 2005 and December 2013, medical charts of patients who underwent stent placement for malignant rectal or left colonic obstruction were reviewed retrospectively. Study intervention included self-expandable metal stent placement. Technical success, clinical success, and complications were measured. Technical success rates for the 2 study groups (rectum vs left colon, 93.5% vs 93.1%; p = 0.86) did not differ significantly; however, the clinical success rate was lower in patients with rectal obstruction (85.4% vs 92.1%; p = 0.02). In addition, the complication rate was higher in patients with rectal obstruction (37.4% vs 25.1%; p = 0.01). Patients with rectal obstruction showed higher rates of obstruction because of extracolonic malignancy (33.8% vs 15.8%; p < 0.001) and stent use for palliation (78.6% vs 56.3%; p < 0.001). Multivariate analysis indicated obstruction attributed to extracolonic malignancy and covered stent usage to be independent risk factors for clinical failure. Factors predictive of complications in the palliative group were total obstruction, obstruction because of extracolonic malignancy, and covered stent usage. This was a retrospective, single-center study. The efficacy and safety of stent placement for malignant rectal obstruction were comparable with those for left colonic obstruction. However, obstruction attributed to extracolonic malignancy, use of covered stents, and total obstruction negatively impacted clinical outcomes of self-expandable metal stent placement and must be considered by endoscopists. See Video Abstract at http://links.lww.com/DCR/A417.

  11. [Self-expandable metallic biliary endoprosthesis in malignant obstructive jaundice].

    PubMed

    Güitrón-Cantú, Alfredo; Adalid-Martínez, Raúl; Gutiérrez-Bermúdez, José A

    2005-01-01

    Implantation of metallic stents for malignant biliary strictures has been recognized to be effective alternatives. To show our experience in metallic stents for palliation of malignant biliary strictures. Seventy three patients (38 males, 35 females, mean age 64.26) with malignant biliary strictures have been treated by implantation of metallic stents. Causes of obstruction were pancreatic carcinoma (23/73, 31.5%), bile duct carcinoma (31/73, 42.5%), carcinoma of ampula of Vater (11/73, 15%) and Klatskin tumor (3/73, 4.1%). Endoscopic procedure was successful in all cases. Neither procedure-related morbidity nor mortality was observed. Life surviving curve was 9 months and showed significant difference (p < 0.0071) in patients with carcinoma of ampula of Vater. Self-expanding metal endoprosthesis is a recognized method of palliation in malignant biliary obstruction. It efficiently relieves jaundice and generally improves comfort and nutritional status during the patient's remaining lifetime. The metallic stents are advantageous in patients surviving 6 months or less.

  12. Nanomaterial Toxicity Screening in Developing Zebrafish Embryos

    EPA Science Inventory

    To assess nanomaterial vertebrate toxicity, a high-content screening assay was created using developing zebrafish, Danio rerio. This included a diverse group of nanomaterials (n=42 total) ranging from metallic (Ag, Au) and metal oxide (CeO2, CuO, TiO2, ZnO) nanoparticles, to non...

  13. THE USEPA'S METAL FINISHING FACILITY RISK SCREENING TOOL (MFFRST)

    EPA Science Inventory

    The US Environmetal ProtectionAgenccy's Metal Finishing
    Facility Risk Screening Tool (MFFRST)

    William M. Barrett Jr, Ph.D. , P.E. ; Paul Harten, Ph.D.1, and Matthew Lorber

    The US Environmental Protection Agency completed the development of the first version of...

  14. Screen-Cage Ion Plating Of Silver On Polycrystalline Alumina

    NASA Technical Reports Server (NTRS)

    Spalvins, Talivaldis; Sliney, Harold E.; Deadmore, Daniel L.

    1995-01-01

    Screen-cage ion plating (SCIP) cost-effective technique offering high throwing power for deposition of adherent metal films on ceramic substrates. Applies silver films to complexly shaped substrates of polycrystalline alumina. Silver adheres tenaciously and reduces friction. SCIP holds promise for applying lubricating soft metallic films to high-temperature ceramic components of advanced combustion engines. Other potential uses include coating substrates with metal for protection against corrosion, depositing electrical conductors on dielectric substrates, making optically reflective or electrically or thermally conductive surface layers, and applying decorative metal coats to ceramic trophies or sculptures.

  15. 76 FR 67793 - Notification of Expanded Pricing Grid for Precious Metals Products Containing Platinum and Gold...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-02

    ... DEPARTMENT OF THE TREASURY United States Mint Notification of Expanded Pricing Grid for Precious... in the Federal Register on January 6, 2009, outlining the new pricing methodology for numismatic... considerably, and is approaching the upper bracket of the pricing grid. As a result, it is necessary to expand...

  16. [A Case of Removable Self-Expandable Metallic Stent(SEMS)Placement for Gastric Tube Stenosis after Esophageal Cancer Resection].

    PubMed

    Yoshikawa, Yukihiro; Yoshikawa, Masato; Kawabata, Ryohei; Yoshida, Yuta; Kawada, Masahiro; Yasuyama, Akinobu; Watase, Chikashi; Koga, Chikato; Hitora, Toshiki; Murakami, Masahiro; Hirota, Masaki; Ikenaga, Masakazu; Shimizu, Junzo; Hasegawa, Junichi

    2015-11-01

    A 68-year-old man underwent esophagectomy for early esophageal cancer. Postoperative upper gastrointestinal series and esophagogastroduodenoscopy showed gastric tube stenosis. To improve passage, a removable self-expandable metallic stent (SEMS) was placed across the stenotic lesion. Two weeks later, the stent was removed, and passage through the gastric tube improved. The patient has no symptoms of stenosis. A removable SEMS could be an option for the treatment of gastric tube stenosis after esophagectomy.

  17. Newborn Screening for Lysosomal Storage Disorders

    PubMed Central

    Peake, Roy W. A.; Bodamer, Olaf A.

    2016-01-01

    Newborn screening is one of the most important public health initiatives to date, focusing on the identification of presymptomatic newborn infants with treatable conditions to reduce morbidity and mortality. The number of screening conditions continues to expand due to advances in screening technologies and the development of novel therapies. Consequently, some of the lysosomal storage disorders are now considered as candidates for newborn screening, although many challenges including identification of late-onset phenotypes remain. This review provides a critical appraisal of the current state of newborn screening for lysosomal storage disorders. PMID:28180027

  18. Carrier screening for single gene disorders.

    PubMed

    Rose, Nancy C; Wick, Myra

    2018-04-01

    Screening for genetic disorders began in 1963 with the initiation of newborn screening for phenylketonuria. Advances in molecular technology have made both newborn screening for newborns affected with serious disorders, and carrier screening of individuals at risk for offspring with genetic disorders, more complex and more widely available. Carrier screening today can be performed secondary to family history-based screening, ethnic-based screening, and expanded carrier screening (ECS). ECS is panel-based screening, which analyzes carrier status for hundreds of genetic disorders irrespective of patient race or ethnicity. In this article, we review the historical and current aspects of carrier screening for single gene disorders, including future research directions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Accelerated exploration of multi-principal element alloys with solid solution phases

    PubMed Central

    Senkov, O.N.; Miller, J.D.; Miracle, D.B.; Woodward, C.

    2015-01-01

    Recent multi-principal element, high entropy alloy (HEA) development strategies vastly expand the number of candidate alloy systems, but also pose a new challenge—how to rapidly screen thousands of candidate alloy systems for targeted properties. Here we develop a new approach to rapidly assess structural metals by combining calculated phase diagrams with simple rules based on the phases present, their transformation temperatures and useful microstructures. We evaluate over 130,000 alloy systems, identifying promising compositions for more time-intensive experimental studies. We find the surprising result that solid solution alloys become less likely as the number of alloy elements increases. This contradicts the major premise of HEAs—that increased configurational entropy increases the stability of disordered solid solution phases. As the number of elements increases, the configurational entropy rises slowly while the probability of at least one pair of elements favouring formation of intermetallic compounds increases more rapidly, explaining this apparent contradiction. PMID:25739749

  20. High density array screening to identify the genetic requirements for transition metal tolerance in Saccharomyces cerevisiae.

    PubMed

    Bleackley, Mark R; Young, Barry P; Loewen, Christopher J R; MacGillivray, Ross T A

    2011-02-01

    Biological systems have developed with a strong dependence on transition metals for accomplishing a number of biochemical reactions. Iron, copper, manganese and zinc are essential for virtually all forms of life with their unique chemistries contributing to a variety of physiological processes including oxygen transport, generation of cellular energy and protein structure and function. Properties of these metals (and to a lesser extent nickel and cobalt) that make them so essential to life also make them extremely cytotoxic in many cases through the formation of damaging oxygen radicals via Fenton chemistry. While life has evolved to exploit the chemistries of transition metals to drive physiological reactions, systems have concomitantly evolved to protect against the damaging effects of these same metals. Saccharomyces cerevisiae is a valuable tool for studying metal homeostasis with many of the genes identified thus far having homologs in higher eukaryotes including humans. Using high density arrays, we have screened a haploid S. cerevisiae deletion set containing 4786 non-essential gene deletions for strains sensitive to each of Fe, Cu, Mn, Ni, Zn and Co and then integrated the six screens using cluster analysis to identify pathways that are unique to individual metals and others with function shared between metals. Genes with no previous implication in metal homeostasis were found to contribute to sensitivity to each metal. Significant overlap was observed between the strains that were sensitive to Mn, Ni, Zn and Co with many of these strains lacking genes for the high affinity Fe transport pathway and genes involved in vacuolar transport and acidification. The results from six genome-wide metal tolerance screens show that there is some commonality between the cellular defenses against the toxicity of Mn, Ni, Zn and Co with Fe and Cu requiring different systems. Additionally, potential new factors been identified that function in tolerance to each of the six metals.

  1. Swedish healthcare providers' perceptions of preconception expanded carrier screening (ECS)-a qualitative study.

    PubMed

    Matar, A; Kihlbom, U; Höglund, A T

    2016-07-01

    Reproductive autonomy, medicalization, and discrimination against disabled and parental responsibility are the main ongoing ethical debates concerning reproductive genetic screening. To examine Swedish healthcare professionals' views on preconception expanded carrier screening (ECS), a qualitative study involving academic and clinical institutions in Sweden was conducted in September 2014 to February 2015. Eleven healthcare professionals including clinicians, geneticists, a midwife, and a genetic counselor were interviewed in depth using a semi-structured interview guide. The questionnaire was constructed after reviewing the main literature and meetings with relevant healthcare providers. The interviews were recorded, transcribed verbatim, and content analyzed for categories and subcategories. Participants nurtured many ethical and non-ethical concerns regarding preconception ECS. Among the ethical concerns were the potential for discrimination, medicalization, concerns with prioritization of healthcare resources, and effects on reproductive freedom. The effects of implementation of preconception ECS, its stakeholders, regulations, and motivation are some of non-ethical concerns. These concerns, if not addressed, may affect the uptake and usage of carrier screening within Swedish healthcare system. As this is a qualitative study with a small non-random sample size, the findings cannot be generalized. The participants had little to no working experience with expanded screening panels. Moreover, the interviews were conducted in English, a second language for the participants, which might have limited the expression of their views. However, the authors claim that the findings may be pertinent to similar settings in other Scandinavian countries.

  2. Combinatorial electrochemical cell array for high throughput screening of micro-fuel-cells and metal/air batteries.

    PubMed

    Jiang, Rongzhong

    2007-07-01

    An electrochemical cell array was designed that contains a common air electrode and 16 microanodes for high throughput screening of both fuel cells (based on polymer electrolyte membrane) and metal/air batteries (based on liquid electrolyte). Electrode materials can easily be coated on the anodes of the electrochemical cell array and screened by switching a graphite probe from one cell to the others. The electrochemical cell array was used to study direct methanol fuel cells (DMFCs), including high throughput screening of electrode catalysts and determination of optimum operating conditions. For screening of DMFCs, there is about 6% relative standard deviation (percentage of standard deviation versus mean value) for discharge current from 10 to 20 mAcm(2). The electrochemical cell array was also used to study tin/air batteries. The effect of Cu content in the anode electrode on the discharge performance of the tin/air battery was investigated. The relative standard deviations for screening of metal/air battery (based on zinc/air) are 2.4%, 3.6%, and 5.1% for discharge current at 50, 100, and 150 mAcm(2), respectively.

  3. Screening of metal-organic frameworks for carbon dioxide capture from flue gas using a combined experimental and modeling approach.

    PubMed

    Yazaydin, A Ozgür; Snurr, Randall Q; Park, Tae-Hong; Koh, Kyoungmoo; Liu, Jian; Levan, M Douglas; Benin, Annabelle I; Jakubczak, Paulina; Lanuza, Mary; Galloway, Douglas B; Low, John J; Willis, Richard R

    2009-12-30

    A diverse collection of 14 metal-organic frameworks (MOFs) was screened for CO(2) capture from flue gas using a combined experimental and modeling approach. Adsorption measurements are reported for the screened MOFs at room temperature up to 1 bar. These data are used to validate a generalized strategy for molecular modeling of CO(2) and other small molecules in MOFs. MOFs possessing a high density of open metal sites are found to adsorb significant amounts of CO(2) even at low pressure. An excellent correlation is found between the heat of adsorption and the amount of CO(2) adsorbed below 1 bar. Molecular modeling can aid in selection of adsorbents for CO(2) capture from flue gas by screening a large number of MOFs.

  4. Can the propensity of protein crystallization be increased by using systematic screening with metals?

    PubMed

    Hegde, Raghurama P; Pavithra, Gowribidanur C; Dey, Debayan; Almo, Steven C; Ramakumar, S; Ramagopal, Udupi A

    2017-09-01

    Protein crystallization is one of the major bottlenecks in protein structure elucidation with new strategies being constantly developed to improve the chances of crystallization. Generally, well-ordered epitopes possessing complementary surface and capable of producing stable inter-protein interactions generate a regular three-dimensional arrangement of protein molecules which eventually results in a crystal lattice. Metals, when used for crystallization, with their various coordination numbers and geometries, can generate such epitopes mediating protein oligomerization and/or establish crystal contacts. Some examples of metal-mediated oligomerization and crystallization together with our experience on metal-mediated crystallization of a putative rRNA methyltransferase from Sinorhizobium meliloti are presented. Analysis of crystal structures from protein data bank (PDB) using a non-redundant data set with a 90% identity cutoff, reveals that around 67% of proteins contain at least one metal ion, with ∼14% containing combination of metal ions. Interestingly, metal containing conditions in most commercially available and popular crystallization kits generally contain only a single metal ion, with combinations of metals only in a very few conditions. Based on the results presented in this review, it appears that the crystallization screens need expansion with systematic screening of metal ions that could be crucial for stabilizing the protein structure or for establishing crystal contact and thereby aiding protein crystallization. © 2017 The Protein Society.

  5. Parents' Decisions to Screen Their Newborn for Fragile X Syndrome. FPG Snapshot #63

    ERIC Educational Resources Information Center

    FPG Child Development Institute, 2011

    2011-01-01

    State newborn screening (NBS) programs have expanded in recent years, and more tests may be added in the future. The expansion of neonatal screening raises ethical, legal, and social questions. The questions surrounding NBS for fragile X syndrome (FXS) typify these concerns. FXS is an X-linked genetic condition that is the most common inherited…

  6. Cost-Effectiveness Analysis of a National Neonatal Hearing Screening Program in China: Conditions for the Scale-Up

    PubMed Central

    Tobe, Ruoyan Gai; Mori, Rintaro; Huang, Lihui; Xu, Lingzhong; Han, Demin; Shibuya, Kenji

    2013-01-01

    Background In 2009, the Chinese Ministry of Health recommended scale-up of routine neonatal hearing screening - previously performed primarily only in select urban hospitals - throughout the entire country. Methods A decision analytical model for a simulated population of all live births in China was developed to compare the costs and health effects of five mutually exclusive interventions: 1) universal screening using Otoacoustic Emission (OAE) and Automated Auditory Brainstem Response (AABR); 2) universal OAE; 3) targeted OAE and AABR; 4) targeted OAE; and 5) no screening. Disability-Adjusted Life Years (DALYs) were calculated for health effects. Results and Discussion Based on the cost-effectiveness and potential health outcomes, the optimal path for scale-up would be to start with targeted OAE and then expand to universal OAE and universal OAE plus AABR. Accessibility of screening, diagnosis, and intervention services significantly affect decision of the options. Conclusion In conclusion, to achieve cost-effectiveness and best health outcomes of the NHS program, the accessibility of screening, diagnosis, and intervention services should be expanded to reach a larger population. The results are thus expected to be of particular benefit in terms of the ‘rolling out’ of the national plan. PMID:23341887

  7. Colorimetric photonic hydrogel aptasensor for the screening of heavy metal ions.

    PubMed

    Ye, Bao-Fen; Zhao, Yuan-Jin; Cheng, Yao; Li, Ting-Ting; Xie, Zhuo-Ying; Zhao, Xiang-Wei; Gu, Zhong-Ze

    2012-09-28

    We have developed a robust method for the visual detection of heavy metal ions (such as Hg(2+) and Pb(2+)) by using aptamer-functionalized colloidal photonic crystal hydrogel (CPCH) films. The CPCHs were derived from a colloidal crystal array of monodisperse silica nanoparticles, which were polymerized within the polyacrylamide hydrogel. The heavy metal ion-responsive aptamers were then cross-linked in the hydrogel network. During detection, the specific binding of heavy metal ions and cross-linked single-stranded aptamers in the hydrogel network caused the hydrogel to shrink, which was detected as a corresponding blue shift in the Bragg diffraction peak position of the CPCHs. The shift value could be used to estimate, quantitatively, the amount of the target ion. It was demonstrated that our CPCH aptasensor could screen a wide concentration range of heavy metal ions with high selectivity and reversibility. In addition, these aptasensors could be rehydrated from dried gels for storage and aptamer protection. It is anticipated that our technology may also be used in the screening of a broad range of metal ions in food, drugs and the environment.

  8. Use of Self-Expanding Metallic Ureteral Stents in the Secondary Treatment of Ureteral Stenosis Following Kidney Transplantation.

    PubMed

    Xu, Guibin; Li, Xun; He, Yongzhong; Zhao, Haibo; Yang, Weiqing; Xie, Qingling

    2015-10-01

    To evaluate the safety and efficacy of self-expanding metal stents in the treatment of ureteral stenosis following kidney transplantation. Seven patients who developed benign stenosis after kidney transplantation were treated by a self-expanding metallic stent implantation from June 2007 to March 2014. All patients had undergone at least one open surgical procedure and one endourologic procedure for treatment of the stenosis. The extent of stenosis varied from 1.2 to 3.7 cm. Ultrasonography, urography, diuretic renography, and urine culture were performed every 3 months after stent insertion. Ureteroscopic examination was performed when needed. Stent placement was technically effective in all cases. The mean operative time was 37 minutes (range, 26-59 minutes). Lower urinary-tract symptoms and the ipsilateral flank pain were common early-stage complications and were greatly relieved after an average of 3 months. The mean follow-up duration was 38 months (range, 13-86 months), and no stent migration or fragmentation was observed. Urothelial hyperplasia occurred in only one patient and was effectively managed with a Double-J stent. Five patients had normal stable renal function; the remaining two had impaired renal function, including one patient with a preoperative renal failure who required dialysis at the end of the follow-up period (36 months). As an alternative to open surgery, implantation of a self-expanding metal stent is a safe and effective treatment for ureteral stenosis in patients who have undergone kidney transplantation.

  9. Conformable covered versus uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction: a randomized prospective study.

    PubMed

    Lim, Sun Gyo; Kim, Jin Hong; Lee, Kee Myung; Shin, Sung Jae; Kim, Chan Gyoo; Kim, Kyung Ho; Kim, Ho Gak; Yang, Chang Heon

    2014-07-01

    A conformable self-expandable metallic stent was developed to overcome the limitation of previous self-expandable metallic stents. The aim of this study was to evaluate outcomes after placement of conformable covered and uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction. A single-blind, randomized, parallel-group, prospective study were conducted in 4 medical centres between March 2009 and July 2012. 134 patients with unresectable malignant gastroduodenal obstruction were assigned to a covered double-layered (n=66) or uncovered unfixed-cell braided (n=68) stent placement group. Primary analysis was performed to compare re-intervention rates between two groups. 120 patients were analysed (59 in the covered group and 61 in the uncovered group). Overall rates of re-intervention were not significantly different between the two groups: 13/59 (22.0%) in the covered group vs. 13/61 (21.3%) in the uncovered group, p=0.999. Stent migration was more frequent in the covered group than in the uncovered group (p=0.003). The tumour ingrowth rate was higher in the uncovered group than in the covered group (p=0.016). The rates of re-intervention did not significantly differ between the two stents. Conformable covered double-layered and uncovered unfixed-cell braided stents were associated with different patterns of stent malfunction. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. Dosimetric impact of the AeroForm tissue expander in postmastectomy radiation therapy: an ex vivo analysis.

    PubMed

    Moni, Janaki; Saleeby, Jonathan; Bannon, Elizabeth; Lo, Yuan-Chyuan; Fitzgerald, Thomas J

    2015-01-01

    To evaluate the effect of the AeroForm (AirXpanders Inc, Palo Alto, CA) tissue expander on the dose distribution in a phantom from a simulated postmastectomy radiation treatment for breast cancer. Experiments were conducted to determine the effect on the dose distribution with the metallic reservoir irradiated independently and with the entire AeroForm tissue expander placed on a RANDO phantom (The Phantom Laboratory, Salem, NY). The metallic reservoir was irradiated on a block of solid water with film at various depths ranging from 0 to 8.2 cm from the surface. The intact 400 cc AeroForm was inflated to full capacity and irradiated while positioned on a RANDO phantom, with 12 optically stimulated luminescent dosimeters (OSLDs) placed at clinically relevant expander-tissue interface points. Film dosimetry with the reservoir perpendicular to film reveals 40% transmission at a depth of 0.7 cm, which increases to 60% at a depth of 8.2 cm. In the parallel position, the results vary depending on which area under the reservoir is examined, indicating that the reservoir is not a uniformly dense object. Testing of the intact expander on the phantom revealed that the average percent difference (measured vs expected dose) was 2.7%, σ = 6.2% with heterogeneity correction and 3.7%, σ = 2.4% without heterogeneity correction. The only position where the OSLD readings were consistently higher than the calculated dose by >5% was at position 1, just deep to the canister at the expander-phantom interface. At this position, the readings varied from 5.2% to 14.5%, regardless of heterogeneity correction. Film dosimetry demonstrated beam attenuation in the shadow of the metallic reservoir in the expander. This decrease in dose was not reproduced on the intact expander on the phantom designed to replicate a clinical setup. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  11. Ultrasound screening of periarticular soft tissue abnormality around metal-on-metal bearings.

    PubMed

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Yoshikawa, Hideki; Sugano, Nobuhiko

    2012-06-01

    Although metal hypersensitivity or pseudotumors are concerns for metal-on-metal (MoM) bearings, detailed pathologies of patterns, severity, and incidence of periprosthetic soft tissue lesions are incompletely understood. We examined the potential of ultrasound for screening of periarticular soft tissue lesions around MoM bearings. Ultrasound examinations were conducted in 88 hips (79 patients) with MoM hip resurfacings or MoM total hip arthroplasties with a large femoral head. Four qualitative ultrasound patterns were shown, including normal pattern in 69 hips, joint-expansion pattern in 11 hips, cystic pattern in 5 hips, and mass pattern in 3 hips. Hips with the latter 3 abnormal patterns showed significantly higher frequency of clinical symptoms, without significant differences of sex, duration of implantation, head sizes, and cup abduction/anteversion angles, compared with hips with normal pattern. Ultrasound examination provides sensitive screening of soft tissue reactions around MoM bearings and may be useful in monitoring progression and defining treatment for periarticular soft tissue abnormalities. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. DEVELOPMENT OF THE METAL FINISHING FACILITY RISK SCREENING TOOL

    EPA Science Inventory

    Enhancement of the US Environmental Protection Agency's
    Metal Finishing Facility Risk Screening Tool (MFFRST)

    William M. Barrett Jr, Ph.D., P.E. , P.E.; Paul Harten, Ph.D.1, Matt Lorber , Charles Peck , and Steve Schwartz, P.E., Q.E.P.3

    Recently, the US Environ...

  13. Alloy design for aircraft engines

    NASA Astrophysics Data System (ADS)

    Pollock, Tresa M.

    2016-08-01

    Metallic materials are fundamental to advanced aircraft engines. While perceived as mature, emerging computational, experimental and processing innovations are expanding the scope for discovery and implementation of new metallic materials for future generations of advanced propulsion systems.

  14. An aviation security (AVSEC) screening demonstrator for the detection of non-metallic threats at 28-33 GHz

    NASA Astrophysics Data System (ADS)

    Salmon, Neil A.; Bowring, Nick; Hutchinson, Simon; Southgate, Matthew; O'Reilly, Dean

    2013-10-01

    The unique selling proposition of millimetre wave technology for security screening is that it provides a stand-off or portal scenario sensing capability for non-metallic threats. The capabilities to detect some non-metallic threats are investigated in this paper, whilst recommissioning the AVSEC portal screening system at the Manchester Metropolitan University. The AVSEC system is a large aperture (1.6 m) portal screening imager which uses spatially incoherent illumination at 28-33 GHz from mode scrambling cavities to illuminate the subject. The imaging capability is critically analysed in terms of this illumination. A novel technique for the measurement of reflectance, refractive index and extinction coefficient is investigated and this then use to characterise the signatures of nitromethane, hexane, methanol, bees wax and baking flour. Millimetre wave images are shown how these liquids in polycarbonate bottles and the other materials appear against the human body.

  15. Evaluation of two-year Jewish genetic disease screening program in Atlanta: insight into community genetic screening approaches.

    PubMed

    Shao, Yunru; Liu, Shuling; Grinzaid, Karen

    2015-04-01

    Improvements in genetic testing technologies have led to the development of expanded carrier screening panels for the Ashkenazi Jewish population; however, there are major inconsistencies in current screening practices. A 2-year pilot program was launched in Atlanta in 2010 to promote and facilitate screening for 19 Jewish genetic diseases. We analyzed data from this program, including participant demographics and outreach efforts. This retrospective analysis is based on a de-identified dataset of 724 screenees. Data were obtained through medical chart review and questionnaires and included demographic information, screening results, response to outreach efforts, and follow-up behavior and preferences. We applied descriptive analysis, chi-square tests, and logistic regression to analyze the data and compare findings with published literature. The majority of participants indicated that they were not pregnant or did not have a partner who was pregnant were affiliated with Jewish organizations and reported 100 % AJ ancestry. Overall, carrier frequency was 1 in 3.9. Friends, rabbis, and family members were the most common influencers of the decision to receive screening. People who were older, had a history of pregnancy, and had been previously screened were more likely to educate others (all p < 0.05). Analysis of this 2-year program indicated that people who are ready to have children or expand their families are more likely to get screened and encourage others to be screened. The most effective outreach efforts targeted influencers who then encouraged screening in the target population. Educating influencers and increasing overall awareness were the most effective outreach strategies.

  16. Method of melting metals to reduce contamination from crucibles

    DOEpatents

    Banker, John G.; Wigginton, Hubert L.

    1977-01-01

    Contamination of metals from crucible materials during melting operations is reduced by coating the interior surface of the crucible with a ceramic non-reactive with the metallic charge and disposing a metal liner formed from a portion of the metallic charge within the coated crucible. The liner protects the ceramic coating during loading of the remainder of the charge and expands against the ceramic coating during heat-up to aid in sintering the coating.

  17. [Treatment of tracheobronchomalacia with expandable metallic stents].

    PubMed

    Antón-Pacheco Sánchez, J; García Vázquez, A; Cuadros García, J; Cano Novillo, I; Villafruela Sanz, M; Berchi García, F J

    2002-10-01

    Tracheomalacia is an unfrequent disease that causes tracheal collapse during breathing. It is generally associated to esophageal atresia, but cases of primary tracheomalacia and others secondary to extrinsic compression, have also been described. Spontaneous resolution is generally the rule and only a few cases need surgical treatment. When this therapy fails or is not indicated for any reason, endoluminal tracheobronchial stents may be used. We have treated two patients with four expandable metallic stents: one had severe tracheomalacia associated to esophageal atresia and the other tracheobronchomalacia secondary to cardiomegaly. Results have been good in both cases.

  18. In Vitro Vascular Toxicity of Manufactured Metal Oxide Nanoparticles: Size Profile Predicts Cellular Specificity, Delivered Dose, and Toxicity

    EPA Science Inventory

    Metal oxide nanoparticles (NPs) are being used in an expanding range of products and applications due to their unique physicochemical properties. In vivo biokinetic studies have demonstrated the ability of metal oxide NPs to translocate to the distal organs, including the cardiov...

  19. Combined effects of metal complexation and size expansion in the electronic structure of DNA base pairs

    NASA Astrophysics Data System (ADS)

    Brancolini, Giorgia; Di Felice, Rosa

    2011-05-01

    Novel DNA derivatives have been recently investigated in the pursuit of modified DNA duplexes to tune the electronic structure of DNA-based assemblies for nanotechnology applications. Size-expanded DNAs (e.g., xDNA) and metalated DNAs (M-DNA) may enhance stacking interactions and induce metallic conductivity, respectively. Here we explore possible ways of tailoring the DNA electronic structure by combining the aromatic size expansion with the metal-doping. We select the salient structures from our recent study on natural DNA pairs complexed with transition metal ions and consider the equivalent model configurations for xDNA pairs. We present the results of density functional theory electronic structure calculations of the metalated expanded base-pairs with various localized basis sets and exchange-correlation functionals. Implicit solvent and coordination water molecules are also included. Our results indicate that the effect of base expansion is largest in Ag-xGC complexes, while Cu-xGC complexes are the most promising candidates for nanowires with enhanced electron transfer and also for on-purpose modification of the DNA double-helix for signal detection.

  20. Nonequilibrium approach regarding metals from a linearised kappa distribution

    NASA Astrophysics Data System (ADS)

    Domenech-Garret, J. L.

    2017-10-01

    The widely used kappa distribution functions develop high-energy tails through an adjustable kappa parameter. The aim of this work is to show that such a parameter can itself be regarded as a function, which entangles information about the sources of disequilibrium. We first derive and analyse an expanded Fermi-Dirac kappa distribution. Later, we use this expanded form to obtain an explicit analytical expression for the kappa parameter of a heated metal on which an external electric field is applied. We show that such a kappa index causes departures from equilibrium depending on the physical magnitudes. Finally, we study the role of temperature and electric field on such a parameter, which characterises the electron population of a metal out of equilibrium.

  1. Graphene based tunable fractal Hilbert curve array broadband radar absorbing screen for radar cross section reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Xianjun, E-mail: xianjun.huang@manchester.ac.uk; College of Electronic Science and Engineering, National University of Defense Technology, Changsha 410073; Hu, Zhirun

    2014-11-15

    This paper proposes a new type of graphene based tunable radar absorbing screen. The absorbing screen consists of Hilbert curve metal strip array and chemical vapour deposition (CVD) graphene sheet. The graphene based screen is not only tunable when the chemical potential of the graphene changes, but also has broadband effective absorption. The absorption bandwidth is from 8.9GHz to 18.1GHz, ie., relative bandwidth of more than 68%, at chemical potential of 0eV, which is significantly wider than that if the graphene sheet had not been employed. As the chemical potential varies from 0 to 0.4eV, the central frequency of themore » screen can be tuned from 13.5GHz to 19.0GHz. In the proposed structure, Hilbert curve metal strip array was designed to provide multiple narrow band resonances, whereas the graphene sheet directly underneath the metal strip array provides tunability and averagely required surface resistance so to significantly extend the screen operation bandwidth by providing broadband impedance matching and absorption. In addition, the thickness of the screen has been optimized to achieve nearly the minimum thickness limitation for a nonmagnetic absorber. The working principle of this absorbing screen is studied in details, and performance under various incident angles is presented. This work extends applications of graphene into tunable microwave radar cross section (RCS) reduction applications.« less

  2. [Fine mesh metal endoprostheses for treatment of extensive cervical and intrathoracic tracheomalacia].

    PubMed

    Wilmes, E; Berger, H; Dienemann, H; Jolk, A

    1994-01-01

    The treatment of tracheal stenoses caused by tracheomalacia is mainly carried out by means of sleeve resection, tracheopexy with ring support or other tracheoplastic operative procedures. If patients cannot be treated by surgical operative strategies, conventional stents are usually used to dilate the trachea. The use of a self-expanding elastic metal prosthesis in 5 patients with tracheal airway obstruction caused by tracheomalacia proved to be a true alternative in the therapy of tracheobronchial stenoses. We report on the long term use of 5 patients with tracheal stenoses treated by implantation of elastic metal wallstents. The implantation of the stents resulted in immediate improvement in respiratory function in all 5 patients. None of the patients experienced complications secondary to the stent placement. The stents were well tolerated (long-time follow-up 26 months). The implantation of self-expanding metal stents type "wallstent" seems to offer alternative possibilities for the treatment of tracheomalacia.

  3. Big pharma screening collections: more of the same or unique libraries? The AstraZeneca-Bayer Pharma AG case.

    PubMed

    Kogej, Thierry; Blomberg, Niklas; Greasley, Peter J; Mundt, Stefan; Vainio, Mikko J; Schamberger, Jens; Schmidt, Georg; Hüser, Jörg

    2013-10-01

    In this study, the screening collections of two major pharmaceutical companies (AstraZeneca and Bayer Pharma AG) have been compared using a 2D molecular fingerprint by a nearest neighborhood approach. Results revealed a low overlap between both collections in terms of compound identity and similarity. This emphasizes the value of screening multiple compound collections to expand the chemical space that can be accessed by high-throughput screening (HTS). Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Management of post-gastrectomy anastomosis site obstruction with a self-expandable metallic stent.

    PubMed

    Cha, Ra Ri; Lee, Sang Soo; Kim, Hyunjin; Kim, Hong Jun; Kim, Tae-Hyo; Jung, Woon Tae; Lee, Ok Jae; Bae, Kyung Soo; Jeong, Sang-Ho; Ha, Chang Yoon

    2015-04-28

    Post-gastrectomy anastomosis site obstruction is a relatively rare complication after a subtotal gastrectomy. We present a case of a 75-year-old man who underwent a truncal vagotomy, omental patch, gastrojejunostomy, and Braun anastomosis for duodenal ulcer perforation and a gastric outlet obstruction. Following the 10(th) postoperative day, the patient complained of abdominal discomfort and vomiting. We diagnosed post-gastrectomy anastomosis site obstruction by an upper gastrointestinal series and an upper endoscopic examination. We inserted a self-expandable metallic stent (SEMS) at the anastomosis site. The stent was fully expanded after deployment. On the day following the stent insertion, the patient began to eat, and his abdominal discomfort was resolved. This paper describes the successful management of post-gastrectomy anastomosis site obstruction with temporary placement of a SEMS.

  5. Computational approaches for de novo design and redesign of metal-binding sites on proteins.

    PubMed

    Akcapinar, Gunseli Bayram; Sezerman, Osman Ugur

    2017-04-28

    Metal ions play pivotal roles in protein structure, function and stability. The functional and structural diversity of proteins in nature expanded with the incorporation of metal ions or clusters in proteins. Approximately one-third of these proteins in the databases contain metal ions. Many biological and chemical processes in nature involve metal ion-binding proteins, aka metalloproteins. Many cellular reactions that underpin life require metalloproteins. Most of the remarkable, complex chemical transformations are catalysed by metalloenzymes. Realization of the importance of metal-binding sites in a variety of cellular events led to the advancement of various computational methods for their prediction and characterization. Furthermore, as structural and functional knowledgebase about metalloproteins is expanding with advances in computational and experimental fields, the focus of the research is now shifting towards de novo design and redesign of metalloproteins to extend nature's own diversity beyond its limits. In this review, we will focus on the computational toolbox for prediction of metal ion-binding sites, de novo metalloprotein design and redesign. We will also give examples of tailor-made artificial metalloproteins designed with the computational toolbox. © 2017 The Author(s).

  6. CE: Tuberculosis: A New Screening Recommendation and an Expanded Approach to Elimination in the United States.

    PubMed

    Parmer, John; Allen, Leeanna; Walton, Wanda

    2017-08-01

    : Nurses play a critical role in the diagnosis and treatment of tuberculosis and in the prevention of tuberculosis transmission through infection control practices. To eliminate tuberculosis in the United States, however, an expanded approach to testing and treating people with latent tuberculosis infection must be implemented. Recently, the U.S. Preventive Services Task Force (USPSTF) issued a new recommendation statement on latent tuberculosis infection testing that expands nurses' opportunities to identify at-risk populations for tuberculosis prevention. In combination with newer testing methodologies and shorter treatment regimens, implementation of the USPSTF recommendation has the potential to remove previously existing barriers to screening and treatment of both patients and health care providers. This article provides a general overview of tuberculosis transmission, pathogenesis, and epidemiology; presents preventive care recommendations for targeted testing among high-risk groups; and discusses the USPSTF recommendation's applicability to public health and primary care practice in the United States.

  7. Treatment of cuff-related tracheal stenosis with a fully covered retrievable expandable metallic stent.

    PubMed

    Chen, G; Wang, Z; Liang, X; Wang, Y; Wang, Y; Wang, Z; Xian, J

    2013-04-01

    To investigate the clinical effectiveness, complications, and optimal duration of use of covered retrievable expandable metallic stents in the management of cuff-related tracheal stenosis. Twenty-one patients with cuff-related tracheal stenosis, Meyer-Cotton grade II (29%) and III (71%), who underwent fluoroscopically guided placement of covered retrievable expandable metallic stents were studied. Sixty-four-section computed tomography (CT) and bronchovideoscopy were performed prior to stent insertion, 1 month after stent insertion, in the case of stent-related complications, and after stent removal. Clinical manifestations, Hugh-Jones classification, and forced expiratory volume in 1 s (FEV1) were used to evaluate respiratory function before and after stent insertion and removal. The diameter of the stricture and FEV1 changes before insertion and after removal were analysed using the paired samples t-test. A p-value of ≤0.05 was considered statistically significant. Twenty-one patients had 27 covered retrievable expandable metallic stents placed. Stents were electively removed from 20 patients. The median duration of stent placement was 5 months (range 4-12 months). One stent was not removed due to mucopolysaccharidosis type II (MPS II or Hunter syndrome) with tracheomalacia. After stent removal, airway dimensions increased and airway occlusion was symptomatically relieved in all patients. CT and bronchovideoscopy showed patent lumens with increased dimensions. Stent-related complications occurred in 19 (91%) patients, including granulation tissue formation (n = 18, 86%), stent migration and stent expectoration (n = 2, 10%), mucus plugging (n = 1, 5%), and halitosis (n = 6, 29%). Some patients experienced multiple complications, which were all managed effectively while the stent was still in place. There was a statistically significant difference in the diameter of the stricture and FEV1 between the time of stent insertion and removal. An improvement in Hugh-Jones classification of greater than one grade was seen in patients after stent removal. Temporary placement of a fully covered retrievable expandable metallic stent is safe and effective in cuff-related tracheal stenosis. The optimal duration of stent placement may be 4-8 months. Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  8. Preconception carrier screening for multiple disorders: evaluation of a screening offer in a Dutch founder population.

    PubMed

    Mathijssen, Inge B; Holtkamp, Kim C A; Ottenheim, Cecile P E; van Eeten-Nijman, Janneke M C; Lakeman, Phillis; Meijers-Heijboer, Hanne; van Maarle, Merel C; Henneman, Lidewij

    2018-02-01

    Technological developments have enabled carrier screening for multiple disorders. This study evaluated experiences with a preconception carrier screening offer for four recessive disorders in a Dutch founder population. Questionnaires were completed by 182 attendees pretesting and posttesting and by 137 non-attendees. Semistructured interviews were conducted with seven of the eight carrier couples. Attendees were mainly informed about the existence of screening by friends/colleagues (49%) and family members (44%). Familiarity with the genetic disorders was high. Knowledge after counseling increased (p < 0.001); however, still 9%, compared to 29% before counseling, wrongly mentioned an increased risk of having an affected child if both parents are carriers of different disorders. Most attendees (97%) recalled their test results correctly, but two couples reported being carrier of another disorder than reported. Overall, 63% felt worried while waiting for results but anxiety levels returned to normal afterwards. In all, 2/39 (5%) carriers felt less healthy. Screened individuals were very satisfied; they did not regret testing (97%) and would recommend testing to others (97%). The majority (94%) stated that couples should always have a pretest consultation, preferably by a genetic counselor rather than their general practitioner (83%). All carrier couples made reproductive decisions based on their results. Main reason for non-attendance was unawareness of the screening offer. With expanded carrier screening, adequately informing couples pretest and posttesting is of foremost importance. Close influencers (family/friends) can be used to raise awareness of a screening offer. Our findings provide lessons for the implementation of expanded carrier screening panels in other communities and other settings.

  9. Backscatter from metal surfaces in diagnostic radiology.

    PubMed

    Kodera, Y; Schmidt, R A; Chan, H P; Doi, K

    1984-01-01

    Backscatter from four commonly used metals (aluminum, lead, copper, and iron) was measured under diagnostic imaging conditions, using screen-film systems as detectors. The results indicate that for an 80-kV filtered beam and Par Speed/XRP system, backscatter increases as aluminum (Al) thickness increases until it reaches a plateau of approximately 12% at 50 mm Al. The amount of backscatter from any of these four metals increases as the tube voltage is raised from 60 to 115 kV. Measured backscatter depends strongly on the screens used, possibly due to their attenuation and energy response. Backscatter from aluminum was significantly greater than that from the other metals tested.

  10. Screening of native plants and algae growing on fly-ash affected areas near National Thermal Power Corporation, Tanda, Uttar Pradesh, India for accumulation of toxic heavy metals.

    PubMed

    Dwivedi, S; Srivastava, S; Mishra, S; Dixit, B; Kumar, A; Tripathi, R D

    2008-10-30

    The present investigation was carried out to screen native plants growing in fly-ash (FA) contaminated areas near National Thermal Power Corporation, Tanda, Uttar Pradesh, India with a view to using them for the eco-restoration of the area. A total number of 17 plants (9 aquatic, 6 terrestrial and 2 algal species) were collected and screened for heavy metal (Fe, Zn, Cu, Mo, B, Si, Al, Cr, Pb, Cd, Hg and As) accumulation. Differential accumulation of various heavy metals by different species of plants was observed. Hydrilla verticillata was found to be the most efficient metal accumulator among 9 aquatic plants, Eclipta alba among 6 terrestrial plants and Phormedium papyraceum between 2 algal species. In general, the maximum levels of most metals were found in terrestrial plants while the lowest in algal species. However, translocation of the metals from root to shoot was found to be higher in aquatic plants than terrestrial ones. These results suggest that various aquatic, terrestrial and algal species of plants may be used in a synergistic way to remediate and restore the FA contaminated areas.

  11. Laser beam control device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, H.L.

    1976-01-06

    The shutter and beam expander for diverting the output of a high power laser into an absorption body comprises a onepiece metallic structure having a convex spherically shaped portion adapted to be moved into the beam path for simultaneously reflecting and expanding the beam into energy absorption material.

  12. Role of fully covered self-expandable metal stent for treatment of benign biliary strictures and bile leaks.

    PubMed

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee; Rerknimitr, Rungsun

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  13. Y-shaped bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction: data from a referral center for palliative care.

    PubMed

    Di Mitri, R; Mocciaro, F

    2014-01-01

    Malignant hilar strictures are a clinical challenge because of the current therapeutic approach and the poor prognosis. In recent years, self-expandable metallic stents have proven more effective than plastic stents for palliation of malignant hilar strictures, with the bilateral stent-in-stent technique registering a high success rate. We report our experience with Y-shaped endoscopic self-expandable metallic stents placement for treatment of advanced malignant hilar strictures. From April 2009 to August 2012, we prospectively collected data on patients treated with Y-shaped SEMS placement for advanced malignant hilar carcinoma. Data on technical success, clinical success, and complications were collected. Twenty patients (9 males) were treated (mean age 64.2 ± 15.3 years). The grade of malignant hilar strictures according to the Bismuth classification was II in 5 patients (25%), IIIa in 1 (5%), and IV in 14 (70%). The mean bilirubin level was 14.7 ± 4.9 mg/dL. Technical success was achieved in all patients, with a significant reduction in bilirubin levels (2.9 ± 1.7 mg/dL). One patient experienced cholangitis as early complication, while in 2 patients stent ingrowth was observed. No stents migration was recorded. There was no procedure-related mortality. At the end of the follow-up (7.1 ± 3.1 months), 13 of the 20 patients (65%) had died. Our experience confirms endoscopic bilateral self-expandable metallic stents placement with stent-in-stent technique (Y-shaped configuration) as a feasible, effective, and safe procedure for palliation of unresectable malignant hilar strictures.

  14. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    PubMed Central

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks. PMID:22563290

  15. Treatment of esophagopleural fistulas using covered retrievable expandable metallic stents.

    PubMed

    Kim, Tae-Hyung; Shin, Ji Hoon; Kim, Kyung Rae; Park, Jung-Hoon; Kim, Jin Hyoung; Song, Ho-Young

    2014-04-01

    To evaluate the clinical efficacy of placement of covered retrievable expandable metallic stents for esophagopleural fistulas (EPFs). During the period 1997-2013, nine patients with EPF were treated using covered retrievable expandable metallic stents. The underlying causes of EPF were esophageal carcinoma (n = 6), lung cancer (n = 2), and postoperative empyema for Boerhaave syndrome (n = 1). Technical success was achieved in eight patients (88.9%). In one patient, incomplete EPF closure was due to incomplete stent expansion. Clinical success, defined as complete EPF closure within 7 days, was achieved in five patients (55.6%). Overall fistula persistence (n = 1) or reopening (n = 4) occurred in five patients (55.6%) 0-15 days after stent placement. The causes of reopening were due to the gap between the stent and the esophagus (n = 3) or stent migration (n = 1). For fistula persistence or reopening, additional interventional management, such as gastrostomy, stent removal, or stent reinsertion, was performed. Stent migration occurred as a complication in one patient with EPF from a benign cause secondary to postoperative empyema. In the eight patients who died during the follow-up period, the mean and median survival times were 78.8 days and 46 days, respectively. Placement of a covered expandable metallic esophageal stent for the palliative treatment of EPF is technically feasible, although the rate of clinical success was poor secondary to fistula persistence or reopening. Fistula reopening was caused by the gap between the stent and the esophagus or by stent migration, and additional interventional treatment was useful to ensure enteral nutritional support. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  16. Use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats: six cases (2005-2007).

    PubMed

    Berent, Allyson C; Weisse, Chick; Todd, Kimberly; Rondeau, Mark P; Reiter, Alexander M

    2008-11-01

    To determine outcome associated with use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats. Retrospective case series. 3 dogs and 3 cats. All 6 animals had severe inspiratory stertor at initial examination. Two animals had no orifice present at the stenosis. Nasopharyngeal stenosis was diagnosed and stent size determined by use of computed tomography. A percutaneous transluminal angioplasty balloon premounted with a balloon-expandable metallic stent was placed over a guidewire, advanced through the stenotic lesion under fluoroscopic and rhinoscopic guidance, and dilated to restore patency. All animals had immediate resolution of clinical signs after stent placement. The procedure took a median of 38 minutes (range, 22 to 70 minutes). One animal with a stenosis located far caudally needed the tip of the stent resected because of hairball entrapment and exaggerated swallowing. Both animals without an orifice in the stenosis had tissue in-growth requiring a covered stent. All animals were reexamined 6 to 12 weeks after treatment via rhinoscopy, radiography, computed tomography, or a combination of techniques. All animals lacked signs of discomfort; 5 of 6 were breathing normally 12 to 28 months after the procedure. Transnasal balloon-expandable metallic stent placement may represent a rapid, safe, noninvasive, and effective treatment in animals with nasopharyngeal stenosis. If the stenosis is extremely caudal in the nasopharynx, serial balloon dilatation might be considered prior to stent placement. A covered stent should be considered initially if the stenosis is completely closed.

  17. Screen Media and Young Children: Who Benefits?

    ERIC Educational Resources Information Center

    Cardany, Audrey Berger

    2010-01-01

    Since the airing of "Sesame Street" in 1985, television produced for children has expanded to more television shows and educational media that includes videos, DVDs, and computer products. Viewing screen media is pervasive in the environments of young children, and companies are designing products for our youngest viewers--infants and toddlers.…

  18. Expanding Newborn Screening for Lysosomal Disorders: Opportunities and Challenges

    ERIC Educational Resources Information Center

    Waggoner, Darrel J.; Tan, Christopher A.

    2011-01-01

    Newborn screening (NBS), since its implementation in the 1960s, has traditionally been successful in reducing mortality and disability in children with a range of different conditions. Lysosomal storage disorders (LSD) are a heterogeneous group of inherited metabolic diseases that result from lysosomal dysfunction. Based on available treatment and…

  19. Cervical Cancer Screening - Multiple Languages

    MedlinePlus

    ... français) Haitian Creole (Kreyol ayisyen) Hindi (हिन्दी) Japanese (日本語) Korean (한국어) Polish (polski) Portuguese (português) Russian ( ... Screening - हिन्दी (Hindi) PDF American Cancer Society Japanese (日本語) Expand Section Colposcopy - 日本語 (Japanese) Bilingual PDF ...

  20. Metal availability and the expanding network of microbial metabolisms in the Archaean eon

    NASA Astrophysics Data System (ADS)

    Moore, Eli K.; Jelen, Benjamin I.; Giovannelli, Donato; Raanan, Hagai; Falkowski, Paul G.

    2017-09-01

    Life is based on energy gained by electron-transfer processes; these processes rely on oxidoreductase enzymes, which often contain transition metals in their structures. The availability of different metals and substrates has changed over the course of Earth's history as a result of secular changes in redox conditions, particularly global oxygenation. New metabolic pathways using different transition metals co-evolved alongside changing redox conditions. Sulfur reduction, sulfate reduction, methanogenesis and anoxygenic photosynthesis appeared between about 3.8 and 3.4 billion years ago. The oxidoreductases responsible for these metabolisms incorporated metals that were readily available in Archaean oceans, chiefly iron and iron-sulfur clusters. Oxygenic photosynthesis appeared between 3.2 and 2.5 billion years ago, as did methane oxidation, nitrogen fixation, nitrification and denitrification. These metabolisms rely on an expanded range of transition metals presumably made available by the build-up of molecular oxygen in soil crusts and marine microbial mats. The appropriation of copper in enzymes before the Great Oxidation Event is particularly important, as copper is key to nitrogen and methane cycling and was later incorporated into numerous aerobic metabolisms. We find that the diversity of metals used in oxidoreductases has increased through time, suggesting that surface redox potential and metal incorporation influenced the evolution of metabolism, biological electron transfer and microbial ecology.

  1. Pre- and post-testing counseling considerations for the provision of expanded carrier screening: exploration of European geneticists' views.

    PubMed

    Janssens, Sandra; Chokoshvili, Davit; Vears, Danya F; De Paepe, Anne; Borry, Pascal

    2017-08-01

    Carrier screening is generally performed with the aim of identifying healthy couples at risk of having a child affected with a monogenic disorder to provide them with reproductive options. Expanded carrier screening (ECS), which provides the opportunity for multiple conditions to be screened in one test, offers a more cost-effective and comprehensive option than screening for single disorders. However, implementation of ECS at a population level would have implications for genetic counseling practice. We conducted semi-structured interviews with sixteen European clinical and molecular geneticists with expertise in carrier screening to explore their views on the implementation of ECS in the clinical setting. Using inductive content analysis, we identified content categories relevant to the pre- and post-test settings. Participants believed ECS would ideally be targeted at couples before pregnancy. There was some disagreement regarding the acceptability of performing ECS in individuals, with several participants actively opposing individual-based screening. In addition, participants discussed the importance of ensuring informed and voluntary participation in ECS, recommending measures to minimize external pressure on prospective parents to undergo testing. A need for adequate counseling to foster informed, autonomous reproductive decision-making and provide support for couples found to be at risk was emphasized. Practical challenges in optimizing pre-test education and post-test counseling should not be underestimated and they should be carefully addressed before implementing ECS in the clinical setting.

  2. On the Numerical Analysis of Decay Rate Enhancement in Metallic Environment

    NASA Astrophysics Data System (ADS)

    Mehedinteanu, S.

    2007-10-01

    Motivated on the very recent experiments to determine the acceleration of the alpha decay of meta-stable radionuclides in metallic environment some work has been done to strengthten the importance in the process of electrons screening in metals. Thus, by combining the Gamow decay theory with electrostatic screening in Debye-Hückel approximation (jellium model) a formula for ``the shift'' in screening energy which enters in the decay enhancement factor expression that copes well with these experiments has been derived. It was established that to simulate the poly-atoms system containing decaying isotopes in QM&MD codes calculations, and to include ``the screening energy shift'' of protons, decay alpha, beta+ particles due to all surrounding interacting effects, it is sufficiently only to substitute the code ruly pseudo-potential input for hydrogen-like atoms (including alpha) by a screened Coulomb potential as from the well-known Gamow alpha decay theory. For demonstration is used the QM&MD code package which usually performs density-functional theory (DFT) total-energy calculations for materials ranging from insulators to transition metals. This package employs first-principles pseudo-potentials and a plane-wave basis-set, and it was used to do a special calculus for some metal environments (Pd) where protons-deuterons are implanted or when it is alloyed with a radionuclide-like isotopes (174Hf72), the results compare well with the existing experiments on the decay enhancement. These works give further arguments for a cheap solution to remove the transuranic waste (involving all alpha-decay) of used-up rods of fission reactors in a time period of a few years.

  3. Coverage and Preventive Screening

    PubMed Central

    Meeker, Daniella; Joyce, Geoffrey F; Malkin, Jesse; Teutsch, Steven M; Haddix, Anne C; Goldman, Dana P

    2011-01-01

    Context Preventive care has been shown as a high-value health care service. Many employers now offer expanded coverage of preventive care to encourage utilization. Objective To determine whether expanding coverage is an effective means to encourage utilization. Design Comparison of screening rates before and after introduction of deductible-free coverage. Setting People insured through large corporations between 2002 and 2006. Patients or Other Participants Preferred Provider Organization (PPO) enrollees from an employer introducing deductible-free coverage, and a control group enrolled in a PPO from a second employer with no policy change. Main Outcome Measures Adjusted probability of endoscopy, fecal occult blood test (FOBT), lipid screens, mammography, and Papanicolaou (pap) smears. Intervention Introduction of first-dollar coverage (FDC) of preventive services in 2003. Results After adjusting for demographics and secular trends, there were between 23 and 78 additional uses per 1,000 eligible patients of covered preventive screens (lipid screens, pap smears, mammograms, and FOBT), with no significant changes in the control group or in a service without FDC (endoscopy). Conclusions FDC improves utilization modestly among healthy individuals, particularly those in lower deductible plans. Compliance with guidelines can be encouraged by lowering out-of-pocket costs, but patients' predisposing characteristics merit attention. PMID:21029084

  4. Cystic Fibrosis Diagnosis and Newborn Screening.

    PubMed

    Rosenfeld, Margaret; Sontag, Marci K; Ren, Clement L

    2016-08-01

    The diagnosis of cystic fibrosis (CF) has evolved over the past decade as newborn screening has become universal in the United States and elsewhere. The heterogeneity of phenotypes associated with CF transmembrane conductance regulator (CFTR) dysfunction and mutations in the CFTR gene has become clearer, ranging from classic pancreatic-insufficient CF to manifestations in only 1 organ system to indeterminate diagnoses identified by newborn screening. The tools available for diagnosis have also expanded. This article reviews the newest diagnostic criteria for CF, newborn screening, prenatal screening and diagnosis, and indeterminate diagnoses in newborn-screened infants and symptomatic adults. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. 46 CFR 164.009-3 - Noncombustible materials not requiring specific approval.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... subpart: (a) Sheet glass, block glass, clay, ceramics, and uncoated fibers. (b) All metals, except... only sand, gravel, expanded vermiculite, expanded or vesicular slags, diatomaceous silica, perlite, or pumice. (d) Woven, knitted or needle punched glass fabric containing no additives other than lubricants...

  6. Backscatter from metal surfaces in diagnostic radiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kodera, Y.; Schmidt, R.A.; Chan, H.P.

    Backscatter from four commonly used metals (aluminum, lead, copper, and iron) was measured under diagnostic imaging conditions, using screen-film systems as detectors. The results indicate that for an 80-kV filtered beam and Par Speed/XRP system, backscatter increases as aluminum (Al) thickness increases until it reaches a plateau of approximately 12% at 50 mm Al. The amount of backscatter depends strongly on the screen used, possibly due to their attenuation and energy response. Backscatter from aluminum was significantly greater than that from the other metals tested.

  7. Expansion of 50 CAG/CTG repeats excluded in schizophrenia by application of a highly efficient approach using repeat expansion detection and a PCR screening set

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowen, T.; Guy, C.; Speight, G.

    Studies of the transmission of schizophrenia in families with affected members in several generations have suggested that an expanded trinucleotide repeat mechanism may contribute to the genetic inheritance of this disorder. Using repeat expansion detection (RED), we and others have previously found that the distribution of CAG/CTG repeat size is larger in patients with schizophrenia than in controls. In an attempt to identify the specific expanded CAG/CTG locus or loci associated with schizophrenia, we have now used an approach based on a CAG/CTG PCR screening set combined with RED data. This has allowed us to minimize genotyping while excluding 43more » polymorphic autosomal loci and 7 X-chromosomal loci from the screening set as candidates for expansion in schizophrenia with a very high degree of confidence. 18 refs., 1 tab.« less

  8. Understanding the Mechanical forces of Self-Expandable Metal Stents in the Biliary Ducts.

    PubMed

    Isayama, Hiroyuki; Nakai, Yousuke; Hamada, Tsuyoshi; Matsubara, Saburo; Kogure, Hirofumi; Koike, Kazuhiko

    2016-12-01

    Self-expandable metallic stent (SEMS) was an effective biliary endoprosthesis. Mechanical properties of SEMS, radial and axial force (RF, AF), may play important roles in the bile duct after placement. RF was well known dilation force and influenced on the occurrence of migration. AF, newly proposed by this author, was defined as the recovery force when the SEMS vended. AF was related with the cause of bile duct kinking, pancreatitis, and cholecystitis due to the compression of the bile duct, orifice of the cystic duct, and pancreatic orifice. Ideal SEMS may show high RF and low AF.

  9. Feasibility of Expanding Services for Very Young Children in the Public Mental Health Setting

    ERIC Educational Resources Information Center

    Knapp, Penelope K.; Ammen, Sue; Arstein-Kerslake, Cindy; Poulsen, Marie Kanne; Mastergeorge, Ann

    2007-01-01

    Objective: A quality-improvement study evaluated the feasibility of training mental health providers to provide mental health screening and relationship-based intervention to expand services for children 0 to 5 years of age in eight California county mental health systems from November 2002 to June 2003. State-level training was provided to more…

  10. Wireless sensor for detecting explosive material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamberti, Vincent E; Howell, Jr., Layton N; Mee, David K

    Disclosed is a sensor for detecting explosive devices. The sensor includes a ferromagnetic metal and a molecular recognition reagent coupled to the ferromagnetic metal. The molecular recognition reagent is operable to expand upon absorption of vapor from an explosive material such that the molecular recognition reagent changes a tensile stress upon the ferromagnetic metal. The explosive device is detected based on changes in the magnetic switching characteristics of the ferromagnetic metal caused by the tensile stress.

  11. A high-performance, flexible and robust metal nanotrough-embedded transparent conducting film for wearable touch screen panels.

    PubMed

    Im, Hyeon-Gyun; An, Byeong Wan; Jin, Jungho; Jang, Junho; Park, Young-Geun; Park, Jang-Ung; Bae, Byeong-Soo

    2016-02-21

    We report a high-performance, flexible and robust metal nanotrough-embedded transparent conducting hybrid film (metal nanotrough-GFRHybrimer). Using an electro-spun polymer nanofiber web as a template and vacuum-deposited gold as a conductor, a junction resistance-free continuous metal nanotrough network is formed. Subsequently, the metal nanotrough is embedded on the surface of a glass-fabric reinforced composite substrate (GFRHybrimer). The monolithic composite structure of our transparent conducting film allows simultaneously high thermal stability (24 h at 250 °C in air), a smooth surface topography (Rrms < 1 nm) and excellent opto-electrical properties. A flexible touch screen panel (TSP) is fabricated using the transparent conducting films. The flexible TSP device stably operates on the back of a human hand and on a wristband.

  12. Backscatter from metal surfaces in diagnostic radiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kodera, Y.; Schmidt, R.A.; Chan, H.P.

    Backscatter from four commonly used metals (aluminum, lead, copper, and iron) was measured under diagnostic imaging conditions, using screen-film systems as detectors. The results indicate that for an 80-kV filtered beam and Par Speed/XRP system, backscatter increases as aluminum (Al) thickness increases until it reaches a plateau of approximately 12% at 50 mm Al. The amount of backscatter from any of these four metals increases as the tube voltage is raised from 60 to 115 kV. Measured backscatter depends strongly on the screens used, possibly due to their attenuation and energy response. Backscatter from aluminum was significantly greater than thatmore » from the other metals tested.« less

  13. The use of expandable metallic airway stents for tracheobronchial obstruction in children.

    PubMed

    Filler, R M; Forte, V; Fraga, J C; Matute, J

    1995-07-01

    Expandable metallic angioplasty stents (Palmaz stent) have been implanted in the trachea and/or bronchi of seven children. Three children had severe tracheal stenosis after tracheoplasty for congenital tracheal stenosis repair, and four had tracheomalacia or bronchomalacia with or without vascular compression. The mean age at stenting was 9.7 months (range, 2 to 15 months). Balloon expandable stents were inserted into the trachea or bronchus through a 3.5-mm bronchoscope under fluoroscopic control. Initially a single tracheal stent was used for all patients except for one with obstruction in the trachea and both bronchi, in whom three stents were implanted. Three children had recurrent airway obstruction 1 month later; one was cured with a second stent; one child died 1 year later; and the other is being treated for heart disease. The others have no serious respiratory problems. The stents in all have been in place for 1 to 25 (mean, 11) months. No immediate complications were noted. Early and late bronchoscopy showed incomplete epithelialization of the stent and patches of granulation tissue on it. Two stents were removed bronchoscopically, one at the completion of treatment for tracheomalacia and the other at the time of recurrent airway obstruction. This preliminary experience indicates that expandable metallic stents have a useful role in the treatment of selected lower airway obstructions.

  14. Biomimetic mineralization of metal-organic frameworks around polysaccharides.

    PubMed

    Liang, Kang; Wang, Ru; Boutter, Manon; Doherty, Cara M; Mulet, Xavier; Richardson, Joseph J

    2017-01-19

    Biomimetic mineralization exploits natural biomineralization processes for the design and fabrication of synthetic functional materials. Here, we report for the first time the use of carbohydrates (polysaccharides) for the biomimetic crystallization of metal-organic frameworks. This discovery greatly expands the potential and diversity of biomimetic approaches for the design, synthesis, and functionalization of new bio-metal-organic framework composite materials.

  15. Management of embedded metallic stents used in the treatment of grades III and IV subglottic, and upper tracheal stenosis in adults.

    PubMed

    Sendi, Khalil; Al-Khatib, Talal; Ahmed, Duha G; Tonkul, Al-Baraa

    2014-11-01

    The aim of this study was to evaluate the post-operative complications of using balloon-expandable metallic stents in treatment of benign, major subglottic and tracheal stenosis in adult patients whom conventional therapy has failed and to demonstrate how to deal with these complications in the long run. A retrospective review of five cases; adlut patiets with benign, major subglottic and upper tracheal stenosis whom were treated with balloon expandable metallic stents at King Abdulaziz University Hospital, in the years between 2008 and 2013. Granulation tissue formed in five of the four cases and restenosis occurred. Other complications encountered were stent infection and dislodgment. The complications were managed by removing the stents surgically via a laryngofissure incision and required the placement of a Montgomery T-tube. Managing the restenosis due to granulation tissue formation around the metallic stents is best achieved by removing the embedded metallic stents surgically via open technique and then by placement of a Montgomery T-tube as a bridging option to successful decannulation. Open surgical procedures remain the mainstay treatment for advanced airway stenosis.

  16. Energy Deposition and Condition of the Metal Core in Exploding Wire Experiments

    NASA Astrophysics Data System (ADS)

    Sarkisov, G. S.; Rosenthal, S. E.; Struve, K. W.; McDaniel, D. H.; Waisman, E. M.; Sasorov, P. V.

    2002-11-01

    Measurements of the Joule energy deposition into exploding wire and its relation with condition of the expanding wire core are presented. Wires of nine different metals with diameters of 10-30 microns, have been exploded by fast 150A/ns and slow 20A/ns pulses, in vacuum and in air. It has been shown by interferometry and light emission that expanding wire core has different conditions. The substances with small atomization enthalpy (Ag, Al, Cu, Au) demonstrate full vaporization of the wire core. The refractory metals (Ti, Pt, Mo, W) demonstrates that core consists from vapor and small and hot microparticles. In this case we observe "firework effect" when large radiation from the wire exceed the energy deposition time in a three order of magnitude. For non-refractory metals radiation dropping fast in 100 ns time scale due to effective adiabatic cooling. It is possible if main part of the metal core was vaporized. The interferometrical investigation of the refraction coefficient of expanding metal core is proof this conclusion. It has been shown that energy deposition before surface breakdown dependent strongly from current rate, surface coatings, environment, wire diameter and radial electric field. The regime of wire explosion in vacuum without shunting plasma shell has been realized for fast exploding mode. In this case we observe anomaly high energy deposition in to the wire core exceeding regular value in almost 20 times. The experimental results for Al wire have been compared with ALEGRA 2D MHD simulations. *Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94AL8500.

  17. Bulk-surface relationship of an electronic structure for high-throughput screening of metal oxide catalysts

    NASA Astrophysics Data System (ADS)

    Kweun, Joshua Minwoo; Li, Chenzhe; Zheng, Yongping; Cho, Maenghyo; Kim, Yoon Young; Cho, Kyeongjae

    2016-05-01

    Designing metal-oxides consisting of earth-abundant elements has been a crucial issue to replace precious metal catalysts. To achieve efficient screening of metal-oxide catalysts via bulk descriptors rather than surface descriptors, we investigated the relationship between the electronic structure of bulk and that of the surface for lanthanum-based perovskite oxides, LaMO3 (M = Ti, V, Cr, Mn, Fe, Co, Ni, Cu). Through density functional theory calculations, we examined the d-band occupancy of the bulk and surface transition-metal atoms (nBulk and nSurf) and the adsorption energy of an oxygen atom (Eads) on (001), (110), and (111) surfaces. For the (001) surface, we observed strong correlation between the nBulk and nSurf with an R-squared value over 94%, and the result was interpreted in terms of ligand field splitting and antibonding/bonding level splitting. Moreover, the Eads on the surfaces was highly correlated with the nBulk with an R-squared value of more than 94%, and different surface relaxations could be explained by the bulk electronic structure (e.g., LaMnO3 vs. LaTiO3). These results suggest that a bulk-derived descriptor such as nBulk can be used to screen metal-oxide catalysts.

  18. Review of the Potential of the Ni/Cu Plating Technique for Crystalline Silicon Solar Cells

    PubMed Central

    Rehman, Atteq ur; Lee, Soo Hong

    2014-01-01

    Developing a better method for the metallization of silicon solar cells is integral part of realizing superior efficiency. Currently, contact realization using screen printing is the leading technology in the silicon based photovoltaic industry, as it is simple and fast. However, the problem with metallization of this kind is that it has a lower aspect ratio and higher contact resistance, which limits solar cell efficiency. The mounting cost of silver pastes and decreasing silicon wafer thicknesses encourages silicon solar cell manufacturers to develop fresh metallization techniques involving a lower quantity of silver usage and not relying pressing process of screen printing. In recent times nickel/copper (Ni/Cu) based metal plating has emerged as a metallization method that may solve these issues. This paper offers a detailed review and understanding of a Ni/Cu based plating technique for silicon solar cells. The formation of a Ni seed layer by adopting various deposition techniques and a Cu conducting layer using a light induced plating (LIP) process are appraised. Unlike screen-printed metallization, a step involving patterning is crucial for opening the masking layer. Consequently, experimental procedures involving patterning methods are also explicated. Lastly, the issues of adhesion, back ground plating, process complexity and reliability for industrial applications are also addressed. PMID:28788516

  19. Review of the Potential of the Ni/Cu Plating Technique for Crystalline Silicon Solar Cells.

    PubMed

    Rehman, Atteq Ur; Lee, Soo Hong

    2014-02-18

    Developing a better method for the metallization of silicon solar cells is integral part of realizing superior efficiency. Currently, contact realization using screen printing is the leading technology in the silicon based photovoltaic industry, as it is simple and fast. However, the problem with metallization of this kind is that it has a lower aspect ratio and higher contact resistance, which limits solar cell efficiency. The mounting cost of silver pastes and decreasing silicon wafer thicknesses encourages silicon solar cell manufacturers to develop fresh metallization techniques involving a lower quantity of silver usage and not relying pressing process of screen printing. In recent times nickel/copper (Ni/Cu) based metal plating has emerged as a metallization method that may solve these issues. This paper offers a detailed review and understanding of a Ni/Cu based plating technique for silicon solar cells. The formation of a Ni seed layer by adopting various deposition techniques and a Cu conducting layer using a light induced plating (LIP) process are appraised. Unlike screen-printed metallization, a step involving patterning is crucial for opening the masking layer. Consequently, experimental procedures involving patterning methods are also explicated. Lastly, the issues of adhesion, back ground plating, process complexity and reliability for industrial applications are also addressed.

  20. A multi-element screening method to identify metal targets for blood biomonitoring in green sea turtles (Chelonia mydas).

    PubMed

    Villa, C A; Finlayson, S; Limpus, C; Gaus, C

    2015-04-15

    Biomonitoring of blood is commonly used to identify and quantify occupational or environmental exposure to chemical contaminants. Increasingly, this technique has been applied to wildlife contaminant monitoring, including for green turtles, allowing for the non-lethal evaluation of chemical exposure in their nearshore environment. The sources, composition, bioavailability and toxicity of metals in the marine environment are, however, often unknown and influenced by numerous biotic and abiotic factors. These factors can vary considerably across time and space making the selection of the most informative elements for biomonitoring challenging. This study aimed to validate an ICP-MS multi-element screening method for green turtle blood in order to identify and facilitate prioritisation of target metals for subsequent fully quantitative analysis. Multi-element screening provided semiquantitative results for 70 elements, 28 of which were also determined through fully quantitative analysis. Of the 28 comparable elements, 23 of the semiquantitative results had an accuracy between 67% and 112% relative to the fully quantified values. In lieu of any available turtle certified reference materials (CRMs), we evaluated the use of human blood CRMs as a matrix surrogate for quality control, and compared two commonly used sample preparation methods for matrix related effects. The results demonstrate that human blood provides an appropriate matrix for use as a quality control material in the fully quantitative analysis of metals in turtle blood. An example for the application of this screening method is provided by comparing screening results from blood of green turtles foraging in an urban and rural region in Queensland, Australia. Potential targets for future metal biomonitoring in these regions were identified by this approach. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Covered duodenal self-expandable metal stents prolong biliary stent patency in double stenting: The largest series of bilioduodenal obstruction.

    PubMed

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Kondo, Hiromu; Yoshida, Michihiro; Shimizu, Shuya; Hirano, Atsuyuki; Okumura, Fumihiro; Ando, Tomoaki; Jinno, Naruomi; Takada, Hiroki; Togawa, Shozo; Joh, Takashi

    2018-03-01

    Endoscopic biliary and duodenal stenting (DS; double stenting) is widely accepted as a palliation therapy for malignant bilioduodenal obstruction. The aim of the current study was to investigate the patency and adverse events of duodenal and biliary stents in patients with DS. Patients who underwent DS from April 2004 to March 2017 were analyzed retrospectively with regard to clinical outcomes and predictive factors of recurrent biliary and duodenal obstruction (recurrent biliary obstruction [RBO] and recurrent duodenal obstruction [RDO]). A total of 109 consecutive patients was enrolled. Technical success of DS was achieved in 108 patients (99.1%). Symptoms due to biliary and duodenal obstruction were improved in 89 patients (81.7%). RBO occurred in 25 patients (22.9%) and RDO in 13 (11.9%). The median times to RBO and RDO from DS were 87 and 76 days, respectively. Placement of a duodenal uncovered self-expandable metal stent (U-SEMS) was significantly associated with RBO in the multivariable analysis (P = 0.007). Time to RBO was significantly longer in the duodenal covered self-expandable metal stent group than in the U-SEMS group (P = 0.003). No predictive factors of RDO were detected, and duodenal stent type was not associated with the time to RDO (P = 0.724). Double stenting was safe and effective for malignant bilioduodenal obstruction. Duodenal U-SEMS is a risk factor for RBO. The covered self-expandable metal stent is the preferred type of duodenal SEMS in patients with DS (Clinical trial registration number: UMIN000027606). © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  2. Metalizing Solar Cells by Selective Electroplating

    NASA Technical Reports Server (NTRS)

    Dutta, S.; Palaschak, P. A.

    1986-01-01

    Contact patterns traced by laser scanning. Conductor paths deposited on silicon solar-cell wafers by laser irradiation followed by electroplating. Laser-assisted metalization technique offers better resolution and lower contact resistance than does conventional metalization by screen printing. At the same time, less expensive than metalization with masks and photolithography.

  3. Density Functional Theory and Beyond for Band-Gap Screening: Performance for Transition-Metal Oxides and Dichalcogenides.

    PubMed

    Li, Wenqing; Walther, Christian F J; Kuc, Agnieszka; Heine, Thomas

    2013-07-09

    The performance of a wide variety of commonly used density functionals, as well as two screened hybrid functionals (HSE06 and TB-mBJ), on predicting electronic structures of a large class of en vogue materials, such as metal oxides, chalcogenides, and nitrides, is discussed in terms of band gaps, band structures, and projected electronic densities of states. Contrary to GGA, hybrid functionals and GGA+U, both HSE06 and TB-mBJ are able to predict band gaps with an appreciable accuracy of 25% and thus allow the screening of various classes of transition-metal-based compounds, i.e., mixed or doped materials, at modest computational cost. The calculated electronic structures are largely unaffected by the choice of basis functions and software implementation, however, might be subject to the treatment of the core electrons.

  4. Wireless sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamberti, Vincent E.; Howell, JR, Layton N.; Mee, David K.

    Disclosed is a sensor for detecting a target material. The sensor includes a ferromagnetic metal and a molecular recognition reagent coupled to the ferromagnetic metal. The molecular recognition reagent is operable to expand upon exposure to vapor or liquid from the target material such that the molecular recognition reagent changes a tensile stress upon the ferromagnetic metal. The target material is detected based on changes in the magnetic switching characteristics of the ferromagnetic metal caused by the changes in the tensile stress.

  5. Medium-term follow-up after deployment of ultraflex expandable metallic stents to manage endobronchial pathology.

    PubMed

    Madden, Brendan P; Park, John E S; Sheth, Abhijat

    2004-12-01

    Between March 1997 and March 2004 we deployed 80 Ultraflex metallic expandable stents (Boston Scientific, Waterson, MA) in 69 patients under direct vision using rigid bronchoscopy. We report our medium- to long-term experience in patients for whom these stents were deployed. To date 15 patients have been followed for more than 1 year (median 41 months, range 12 to 83 months) after stent deployment. Indications for stenting in these patients were neoplasia (5), stricture (5), airway malacia (1), iatrogenic tracheal tear (1), and compression from an aortic aneurysm (1), a right interrupted aortic arch (1), and a right brachiocephalic artery aneurysm with tracheomalacia (1). Ten tracheal stents (9 covered, 1 uncovered) and 10 bronchial stents (8 uncovered, 2 covered) were inserted, and 5 patients received two stents. Five of these patients experienced no long-term problems. Complications included troublesome halitosis (5), which was difficult to treat despite various antibiotic regimes; granulation tissue formation above and below the stent that was successfully treated with low-power Nd:YAG laser therapy (7); and metal fatigue (1). We did not encounter stent migration. We conclude that Ultraflex expandable metallic stents have an important role in the management of selected patients with diverse endobronchial pathologies and are well tolerated in the long-term. Although associated granulation tissue can be successfully treated with Nd:YAG laser, halitosis can be a difficult problem to address.

  6. Soil criteria to protect terrestrial wildlife and open-range livestock from metal toxicity at mining sites.

    PubMed

    Ford, Karl L; Beyer, W Nelson

    2014-03-01

    Thousands of hard rock mines exist in the western USA and in other parts of the world as a result of historic and current gold, silver, lead, and mercury mining. Many of these sites in the USA are on public lands. Typical mine waste associated with these sites are tailings and waste rock dumps that may be used by wildlife and open-range livestock. This report provides wildlife screening criteria levels for metals in soil and mine waste to evaluate risk and to determine the need for site-specific risk assessment, remediation, or a change in management practices. The screening levels are calculated from toxicity reference values based on maximum tolerable levels of metals in feed, on soil and plant ingestion rates, and on soil to plant uptake factors for a variety of receptors. The metals chosen for this report are common toxic metals found at mining sites: arsenic, cadmium, copper, lead, mercury, and zinc. The resulting soil screening values are well above those developed by the US Environmental Protection Agency. The difference in values was mainly a result of using toxicity reference values that were more specific to the receptors addressed rather than the most sensitive receptor.

  7. Soil criteria to protect terrestrial wildlife and open-range livestock from metal toxicity at mining sites

    USGS Publications Warehouse

    Ford, Karl L; Beyer, W. Nelson

    2014-01-01

    Thousands of hard rock mines exist in the western USA and in other parts of the world as a result of historic and current gold, silver, lead, and mercury mining. Many of these sites in the USA are on public lands. Typical mine waste associated with these sites are tailings and waste rock dumps that may be used by wildlife and open-range livestock. This report provides wildlife screening criteria levels for metals in soil and mine waste to evaluate risk and to determine the need for site-specific risk assessment, remediation, or a change in management practices. The screening levels are calculated from toxicity reference values based on maximum tolerable levels of metals in feed, on soil and plant ingestion rates, and on soil to plant uptake factors for a variety of receptors. The metals chosen for this report are common toxic metals found at mining sites: arsenic, cadmium, copper, lead, mercury, and zinc. The resulting soil screening values are well above those developed by the US Environmental Protection Agency. The difference in values was mainly a result of using toxicity reference values that were more specific to the receptors addressed rather than the most sensitive receptor.

  8. Microscreen radiation shield for thermoelectric generator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunt, T.K.; Novak, R.F.; McBride, J.R.

    1990-08-14

    This patent describes a radiation shield adapted to be interposed between a reaction zone and a means for condensing an alkali metal vapor in a thermoelectric generator for converting heat energy directly to electrical energy. The radiation shield comprises woven wire mesh screen, the spacing between the wires forming the mesh screen being such that the radiation shield reflects thermal radiation while permitting the passage of alkali metal vapor therethrough.

  9. Fungal community structure under goat willows (Salix caprea L.) growing at metal polluted site: the potential of screening in a model phytostabilisation study

    Treesearch

    Marjana Regvar; Matevz Likar; Andrej Piltaver; Nives Kugonic; Jane E. Smith

    2010-01-01

    Goat willow (Salix caprea L.) was selected in a previous vegetation screening study as a potential candidate for the later-stage phytostabilisation efforts at a heavily metal polluted site in Slovenia. The aims of this study were to identify the fungi colonising roots of S. caprea along the gradient of vegetation succession and...

  10. Ignition of expandable polystyrene foam by a hot particle: an experimental and numerical study.

    PubMed

    Wang, Supan; Chen, Haixiang; Liu, Naian

    2015-01-01

    Many serious fires have occurred in recent years due to the ignition of external building insulation materials by hot metallic particles. This work studied the ignition of expandable polystyrene foam by hot metallic particles experimentally and numerically. In each experiment, a spherical steel particle was heated to a high temperature (within 1173-1373K) and then dropped to the surface of an expandable polystyrene foam block. The particles used in experiments ranged from 3mm to 7 mm in radius. The observed results for ignition were categorized into two types: "flaming ignition" and "no ignition", and the flaming ignition limit was determined by statistical analysis. According to the experimental observations, a numerical model was proposed, taking into account the reactant consumption and volatiles convection of expandable polystyrene decomposition in air. Three regimes, no ignition, unstable ignition and stable ignition, were identified, and two critical particle temperatures for separating the three regimes were determined. Comparison with the experimental data shows that the model can predict the range of critical ignition temperatures reasonably well. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Expandable Metal Liner For Downhole Components

    DOEpatents

    Hall, David R.; Fox, Joe R.

    2004-10-05

    A liner for an annular downhole component is comprised of an expandable metal tube having indentations along its surface. The indentations are formed in the wall of the tube either by drawing the tube through a die, by hydroforming, by stamping, or roll forming and may extend axially, radially, or spirally along its wall. The indentations accommodate radial and axial expansion of the tube within the downhole component. The tube is inserted into the annular component and deformed to match an inside surface of the component. The tube may be expanded using a hydroforming process or by drawing a mandrel through the tube. The tube may be expanded in such a manner so as to place it in compression against the inside wall of the component. The tube is useful for improving component hydraulics, shielding components from contamination, inhibiting corrosion, and preventing wear to the downhole component during use. It may also be useful for positioning conduit and insulated conductors within the component. An insulating material may be disposed between the tube and the component in order to prevent galvanic corrosion of the downhole component.

  12. Treatment of tracheomalacia with Palmaz stent: a case report.

    PubMed

    Inan, Mustafa; Ayvaz, Süleyman; Basaran, Umit Nusret

    2005-01-01

    Tracheomalacia is a potentially life-threatening clinical problem. The expandable Palmaz stent can be used for the treatment of tracheomalacia. We describe a female infant with tracheomalacia who showed respiratory distress the day after birth. Tracheomalacia was diagnosed by bronchoscopic examination, computed tomography and bronchography. At 75 days of age, an expandable metallic stent (Palmaz stent) was inserted into the trachea under fluoroscopic control. The patient's respiratory status improved rapidly. Bronchoscopic examination 6 months after the insertion did not show any granulation tissue. However, in bronchoscopic examination carried out two years later, we detected invasion of the Palmaz stent to the trachea and development of granulation tissue. We think that expandable metallic stent placement should be considered in patients who show intractable respiratory symptoms caused by tracheomalacia in the earlier stages of the treatment. But long-term complications of this procedure are crucial.

  13. The Role of National Library of Medicine[R] Web Sites in Newborn Screening Education

    ERIC Educational Resources Information Center

    Fomous, Cathy; Miller, Naomi

    2006-01-01

    Expanded newborn screening programs and subsequent detection of rare genetic disorders challenge parents and their medical providers to learn about the treatment and management of these disorders. Many people seek medical information on the Internet but may encounter requests for registration or fees, or find that resources are out of date,…

  14. Enhancement of cold fusion in metal ``hydrides'' by screening of proton and deuteron charges

    NASA Astrophysics Data System (ADS)

    Burrows, Adam

    1989-08-01

    The production of fusion heat in a metal hydride (deuteride) lattice is problematic, since the reported ratio of power to neutron or γ-ray flux of some workers is much larger than that for any known conventional complement of fusion reactions. However, enhanced screening of the deuteron or proton charge in the lattice cages might enhance to modest levels the standard d+d-->3He+n,T+p and p+d-->3He+γ fusion reactions. By lowering the effective deuteron-deuteron and proton-deuteron Coulomb barriers, the effective Gamov penetration factor is increased substantially in metals in general, transition metals in particular, and perhaps enough to produce modest neutron fluxes and tritium yields.

  15. Adopted Individuals' Views on the Utility and Value of Expanded Carrier Screening.

    PubMed

    Spencer, Sara; Ewing, Sarah; Calcagno, Kathryn; O'Neill, Suzanne

    2018-03-30

    Adoptees may not have family medical history and ethnicity information. Carrier screening assesses reproductive risk. Expanded carrier screening (ECS) screens for many genetic conditions regardless of a patient's knowledge of family history and ethnicity. This study aimed to better understand the opinions and attitudes of adopted individuals on the use of ECS in determining a patient's reproductive genetic risks. Specifically, the study assessed how adopted individuals feel that results of ECS may be useful to them and whether adoptees feel that meeting with a genetics professional in the process of undergoing ECS would be useful. Adult adoptees (N = 124) were recruited online. Their opinions on ECS were explored. The majority reported they had never been offered carrier screening (92%). The majority of adoptees wanted ECS (76%). Neither the amount of contact with biological relatives nor having medical knowledge about biological relatives was significantly associated with adoptees' desire to pursue ECS. There was a significant positive correlation between adoptees of higher education levels and the amount they would pay for ECS (p = 0.004). The majority of participants (95%) indicated a genetics professional would be helpful when undergoing ECS. The findings suggest this population may want ECS and support from genetics healthcare professionals. Advocacy for genetic counseling and testing for adoptees appears justifiable.

  16. Predictors of the patency of self-expandable metallic stents in malignant gastroduodenal obstruction.

    PubMed

    Kim, Seung Han; Chun, Hoon Jai; Yoo, In Kyung; Lee, Jae Min; Nam, Seung Joo; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck

    2015-08-14

    To investigate the predictive factors of self-expandable metallic stent patency after stent placement in patients with inoperable malignant gastroduodenal obstruction. A total of 116 patients underwent stent placements for inoperable malignant gastroduodenal obstruction at a tertiary academic center. Clinical success was defined as acceptable decompression of the obstructive lesion within the malignant gastroduodenal neoplasm. We evaluated patient comorbidities and clinical statuses using the World Health Organization's scoring system and categorized patient responses to chemotherapy using the Response Evaluation Criteria in Solid Tumors criteria. We analyzed the relationships between possible predictive factors and stent patency. Self-expandable metallic stent placement was technically successful in all patients (100%), and the clinical success rate was 84.2%. In a multivariate Cox proportional hazards model, carcinoembryonic antigen (CEA) levels were correlated with a reduction in stent patency [P = 0.006; adjusted hazard ratio (aHR) = 2.92, 95%CI: 1.36-6.25]. Palliative chemotherapy was statistically associated with an increase in stent patency (P = 0.009; aHR = 0.27, 95%CI: 0.10-0.72). CEA levels can easily be measured at the time of stent placement and may help clinicians to predict stent patency and determine the appropriate stent procedure.

  17. Structural Evaluation of Radially Expandable Cardiovascular Stents Encased in a Polyurethane Film

    NASA Technical Reports Server (NTRS)

    Trigwell, Steve; De, Samiran; Sharma, Rajesh; Mazumder, Malay K.; Mehta, Jawahar L.

    2004-01-01

    A method of encasing cardiovascular stents with an expandable polyurethane coating has been developed to provide a smooth homogeneous inner wall allowing for a confluent growth of endothelial cells. In this design, the metal wire stent structure is completely covered by the polyurethane film minimizing biocorrosion of the metal (stainless steel or nitinol), and providing a homogeneous surface for surface treatment and incorporation of various eluting drugs to prevent platelet aggregation while supporting endothelialization. The polyurethane surface was treated with a helium plasma for sterilization and promotes growth of cells. The paper details the performance of the coated film to expand with the metal stent up to 225 % during deployment. We present stress/strain behavior of polyurethane films, and subsequent plasma treatment of the surface and the adhesion of the coating to the stent structure upon expansion. A film of less than 25 tm was found to be sufficient for corrosion resistance and flexibility without producing any excess stress on the stent structure. Straining the film to 225 % and plasma modification did not affect the mechanical and surface properties while allowing for improved biocompatibility as determined by the critical surface tension, surface chemistry, and roughness.

  18. 12. BUILDING 621, INTERIOR, GROUND FLOOR, LOOKING NORTHWEST AT SCREENING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. BUILDING 621, INTERIOR, GROUND FLOOR, LOOKING NORTHWEST AT SCREENING MACHINE THAT REMOVES SHELL FRAGMENTS. METALLIC DUST REMOVED BY MAGNETIC SEPERATOR UNDERNEATH SCREEN. SAWDUST IS RETURNED TO SAWDUST HOPPER BY ELEVATOR. HOODS OVER SCREENING MACHINE AT WORKBENCH REMOVE FINE SAWDUST. - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ

  19. Expanding metal mixture toxicity models to natural stream and lake invertebrate communities

    USGS Publications Warehouse

    Balistrieri, Laurie S.; Mebane, Christopher A.; Schmidt, Travis S.; Keller, William (Bill)

    2015-01-01

    A modeling approach that was used to predict the toxicity of dissolved single and multiple metals to trout is extended to stream benthic macroinvertebrates, freshwater zooplankton, and Daphnia magna. The approach predicts the accumulation of toxicants (H, Al, Cd, Cu, Ni, Pb, and Zn) in organisms using 3 equilibrium accumulation models that define interactions between dissolved cations and biological receptors (biotic ligands). These models differ in the structure of the receptors and include a 2-site biotic ligand model, a bidentate biotic ligand or 2-pKa model, and a humic acid model. The predicted accumulation of toxicants is weighted using toxicant-specific coefficients and incorporated into a toxicity function called Tox, which is then related to observed mortality or invertebrate community richness using a logistic equation. All accumulation models provide reasonable fits to metal concentrations in tissue samples of stream invertebrates. Despite the good fits, distinct differences in the magnitude of toxicant accumulation and biotic ligand speciation exist among the models for a given solution composition. However, predicted biological responses are similar among the models because there are interdependencies among model parameters in the accumulation–Tox models. To illustrate potential applications of the approaches, the 3 accumulation–Tox models for natural stream invertebrates are used in Monte Carlo simulations to predict the probability of adverse impacts in catchments of differing geology in central Colorado (USA); to link geology, water chemistry, and biological response; and to demonstrate how this approach can be used to screen for potential risks associated with resource development.

  20. Non-invasive prenatal testing for aneuploidy and beyond: challenges of responsible innovation in prenatal screening.

    PubMed

    Dondorp, Wybo; de Wert, Guido; Bombard, Yvonne; Bianchi, Diana W; Bergmann, Carsten; Borry, Pascal; Chitty, Lyn S; Fellmann, Florence; Forzano, Francesca; Hall, Alison; Henneman, Lidewij; Howard, Heidi C; Lucassen, Anneke; Ormond, Kelly; Peterlin, Borut; Radojkovic, Dragica; Rogowski, Wolf; Soller, Maria; Tibben, Aad; Tranebjærg, Lisbeth; van El, Carla G; Cornel, Martina C

    2015-11-01

    This paper contains a joint ESHG/ASHG position document with recommendations regarding responsible innovation in prenatal screening with non-invasive prenatal testing (NIPT). By virtue of its greater accuracy and safety with respect to prenatal screening for common autosomal aneuploidies, NIPT has the potential of helping the practice better achieve its aim of facilitating autonomous reproductive choices, provided that balanced pretest information and non-directive counseling are available as part of the screening offer. Depending on the health-care setting, different scenarios for NIPT-based screening for common autosomal aneuploidies are possible. The trade-offs involved in these scenarios should be assessed in light of the aim of screening, the balance of benefits and burdens for pregnant women and their partners and considerations of cost-effectiveness and justice. With improving screening technologies and decreasing costs of sequencing and analysis, it will become possible in the near future to significantly expand the scope of prenatal screening beyond common autosomal aneuploidies. Commercial providers have already begun expanding their tests to include sex-chromosomal abnormalities and microdeletions. However, multiple false positives may undermine the main achievement of NIPT in the context of prenatal screening: the significant reduction of the invasive testing rate. This document argues for a cautious expansion of the scope of prenatal screening to serious congenital and childhood disorders, only following sound validation studies and a comprehensive evaluation of all relevant aspects. A further core message of this document is that in countries where prenatal screening is offered as a public health programme, governments and public health authorities should adopt an active role to ensure the responsible innovation of prenatal screening on the basis of ethical principles. Crucial elements are the quality of the screening process as a whole (including non-laboratory aspects such as information and counseling), education of professionals, systematic evaluation of all aspects of prenatal screening, development of better evaluation tools in the light of the aim of the practice, accountability to all stakeholders including children born from screened pregnancies and persons living with the conditions targeted in prenatal screening and promotion of equity of access.

  1. Non-invasive prenatal testing for aneuploidy and beyond: challenges of responsible innovation in prenatal screening

    PubMed Central

    Dondorp, Wybo; de Wert, Guido; Bombard, Yvonne; Bianchi, Diana W; Bergmann, Carsten; Borry, Pascal; Chitty, Lyn S; Fellmann, Florence; Forzano, Francesca; Hall, Alison; Henneman, Lidewij; Howard, Heidi C; Lucassen, Anneke; Ormond, Kelly; Peterlin, Borut; Radojkovic, Dragica; Rogowski, Wolf; Soller, Maria; Tibben, Aad; Tranebjærg, Lisbeth; van El, Carla G; Cornel, Martina C

    2015-01-01

    This paper contains a joint ESHG/ASHG position document with recommendations regarding responsible innovation in prenatal screening with non-invasive prenatal testing (NIPT). By virtue of its greater accuracy and safety with respect to prenatal screening for common autosomal aneuploidies, NIPT has the potential of helping the practice better achieve its aim of facilitating autonomous reproductive choices, provided that balanced pretest information and non-directive counseling are available as part of the screening offer. Depending on the health-care setting, different scenarios for NIPT-based screening for common autosomal aneuploidies are possible. The trade-offs involved in these scenarios should be assessed in light of the aim of screening, the balance of benefits and burdens for pregnant women and their partners and considerations of cost-effectiveness and justice. With improving screening technologies and decreasing costs of sequencing and analysis, it will become possible in the near future to significantly expand the scope of prenatal screening beyond common autosomal aneuploidies. Commercial providers have already begun expanding their tests to include sex-chromosomal abnormalities and microdeletions. However, multiple false positives may undermine the main achievement of NIPT in the context of prenatal screening: the significant reduction of the invasive testing rate. This document argues for a cautious expansion of the scope of prenatal screening to serious congenital and childhood disorders, only following sound validation studies and a comprehensive evaluation of all relevant aspects. A further core message of this document is that in countries where prenatal screening is offered as a public health programme, governments and public health authorities should adopt an active role to ensure the responsible innovation of prenatal screening on the basis of ethical principles. Crucial elements are the quality of the screening process as a whole (including non-laboratory aspects such as information and counseling), education of professionals, systematic evaluation of all aspects of prenatal screening, development of better evaluation tools in the light of the aim of the practice, accountability to all stakeholders including children born from screened pregnancies and persons living with the conditions targeted in prenatal screening and promotion of equity of access. PMID:25782669

  2. T-screen and yeast assay for the detection of the thyroid-disrupting activities of cadmium, mercury, and zinc.

    PubMed

    Li, Jian; Liu, Yun; Kong, Dongdong; Ren, Shujuan; Li, Na

    2016-05-01

    In the present study, a two-hybrid yeast bioassay and a T-screen were used to screen for the thyroid receptor (TR)-disrupting activity of select metallic compounds (CdCl2, ZnCl2, HgCl2, CuSO4, MnSO4, and MgSO4). The results reveal that none of the tested metallic compounds showed TR-agonistic activity, whereas ZnCl2, HgCl2, and CdCl2 demonstrated TR antagonism. For the yeast assay, the dose-response relationship of these metallic compounds was established, and the concentrations producing 20 % of the maximum effect of ZnCl2, HgCl2, and CdCl2 were 9.1 × 10(-5), 3.2 × 10(-6), and 1.2 × 10(-6) mol/L, respectively. The T-screen also supported the finding that ZnCl2, HgCl2, and CdCl2 decreased the cell proliferation at concentrations ranging from 10(-6) to 10(-4) mol/L. Furthermore, the thyroid-disrupting activity of metallic compounds in environmental water samples collected from the Guanting Reservoir, Beijing, China was evaluated. Solid-phase extraction was used to separate the organic extracts, and a modified two-hybrid yeast bioassay revealed that the metallic compounds in the water samples could affect thyroid hormone-induced signaling by decreasing the binding of the thyroid hormone. The addition of ethylenediaminetetraacetic acid (30 mg/L) could eliminate the effects. Thus, the cause(s) of the thyroid toxicity in the water samples appeared to be partly related to the metallic compounds.

  3. Accelerated test techniques for micro-circuits: Evaluation of high temperature (473 k - 573 K) accelerated life test techniques as effective microcircuit screening methods

    NASA Technical Reports Server (NTRS)

    Johnson, G. M.

    1976-01-01

    The application of high temperature accelerated test techniques was shown to be an effective method of microcircuit defect screening. Comprehensive microcircuit evaluations and a series of high temperature (473 K to 573 K) life tests demonstrated that a freak or early failure population of surface contaminated devices could be completely screened in thirty two hours of test at an ambient temperature of 523 K. Equivalent screening at 398 K, as prescribed by current Military and NASA specifications, would have required in excess of 1,500 hours of test. All testing was accomplished with a Texas Instruments' 54L10, low power triple-3 input NAND gate manufactured with a titanium- tungsten (Ti-W), Gold (Au) metallization system. A number of design and/or manufacturing anomalies were also noted with the Ti-W, Au metallization system. Further study of the exact nature and cause(s) of these anomalies is recommended prior to the use of microcircuits with Ti-W, Au metallization in long life/high reliability applications. Photomicrographs of tested circuits are included.

  4. University of Texas Southwestern Medical Center: U01 Natural Products Screening | Office of Cancer Genomics

    Cancer.gov

    The goal of this project was to enlarge the chemical space probed by Project 1 (High-Throughput siRNA Screening of a Non-Small Cell Lung Cancer Cell Line Panel) by screening an expanded natural products library (~40,000) in an effort to further define vulnerabilities and therapeutic targets in non-small cell lung cancer. This new library is derived from a diverse collection of marine bacteria (prepared by Dr. John MacMillan, University of Texas Southwestern).

  5. University of Texas Southwestern Medical Center (UTSW): U01 Natural Products Screening | Office of Cancer Genomics

    Cancer.gov

    The goal of this project was to enlarge the chemical space probed by Project 1 (High-Throughput siRNA Screening of a Non-Small Cell Lung Cancer Cell Line Panel) by screening an expanded natural products library (~40,000) in an effort to further define vulnerabilities and therapeutic targets in non-small cell lung cancer. This new library is derived from a diverse collection of marine bacteria (prepared by Dr. John MacMillan, University of Texas Southwestern).

  6. The electromigration force in metallic bulk

    NASA Astrophysics Data System (ADS)

    Lodder, A.; Dekker, J. P.

    1998-01-01

    The voltage induced driving force on a migrating atom in a metallic system is discussed in the perspective of the Hellmann-Feynman force concept, local screening concepts and the linear-response approach. Since the force operator is well defined in quantum mechanics it appears to be only confusing to refer to the Hellmann-Feynman theorem in the context of electromigration. Local screening concepts are shown to be mainly of historical value. The physics involved is completely represented in ab initio local density treatments of dilute alloys and the implementation does not require additional precautions about screening, being typical for jellium treatments. The linear-response approach is shown to be a reliable guide in deciding about the two contributions to the driving force, the direct force and the wind force. Results are given for the wind valence for electromigration in a number of FCC and BCC metals, calculated using an ab initio KKR-Green's function description of a dilute alloy.

  7. Expanded graphite embedded with aluminum nanoparticles as superior thermal conductivity anodes for high-performance lithium-ion batteries

    PubMed Central

    Zhao, Tingkai; She, Shengfei; Ji, Xianglin; Guo, Xinai; Jin, Wenbo; Zhu, Ruoxing; Dang, Alei; Li, Hao; Li, Tiehu; Wei, Bingqing

    2016-01-01

    The development of high capacity and long-life lithium-ion batteries is a long-term pursuing and under a close scrutiny. Most of the researches have been focused on exploring electrode materials and structures with high store capability of lithium ions and at the same time with a good electrical conductivity. Thermal conductivity of an electrode material will also have significant impacts on boosting battery capacity and prolonging battery lifetime, which is, however, underestimated. Here, we present the development of an expanded graphite embedded with Al metal nanoparticles (EG-MNPs-Al) synthesized by an oxidation-expansion process. The synthesized EG-MNPs-Al material exhibited a typical hierarchical structure with embedded Al metal nanoparticles into the interspaces of expanded graphite. The parallel thermal conductivity was up to 11.6 W·m−1·K−1 with a bulk density of 453 kg·m−3 at room temperature, a 150% improvement compared to expanded graphite (4.6 W·m−1·K−1) owing to the existence of Al metal nanoparticles. The first reversible capacity of EG-MNPs-Al as anode material for lithium ion battery was 480 mAh·g−1 at a current density of 100 mA·g−1, and retained 84% capacity after 300 cycles. The improved cycling stability and system security of lithium ion batteries is attributed to the excellent thermal conductivity of the EG-MNPs-Al anodes. PMID:27671848

  8. Expanded graphite embedded with aluminum nanoparticles as superior thermal conductivity anodes for high-performance lithium-ion batteries.

    PubMed

    Zhao, Tingkai; She, Shengfei; Ji, Xianglin; Guo, Xinai; Jin, Wenbo; Zhu, Ruoxing; Dang, Alei; Li, Hao; Li, Tiehu; Wei, Bingqing

    2016-09-27

    The development of high capacity and long-life lithium-ion batteries is a long-term pursuing and under a close scrutiny. Most of the researches have been focused on exploring electrode materials and structures with high store capability of lithium ions and at the same time with a good electrical conductivity. Thermal conductivity of an electrode material will also have significant impacts on boosting battery capacity and prolonging battery lifetime, which is, however, underestimated. Here, we present the development of an expanded graphite embedded with Al metal nanoparticles (EG-MNPs-Al) synthesized by an oxidation-expansion process. The synthesized EG-MNPs-Al material exhibited a typical hierarchical structure with embedded Al metal nanoparticles into the interspaces of expanded graphite. The parallel thermal conductivity was up to 11.6 W·m -1 ·K -1 with a bulk density of 453 kg·m -3 at room temperature, a 150% improvement compared to expanded graphite (4.6 W·m -1 ·K -1 ) owing to the existence of Al metal nanoparticles. The first reversible capacity of EG-MNPs-Al as anode material for lithium ion battery was 480 mAh·g -1 at a current density of 100 mA·g -1 , and retained 84% capacity after 300 cycles. The improved cycling stability and system security of lithium ion batteries is attributed to the excellent thermal conductivity of the EG-MNPs-Al anodes.

  9. High-throughput screening of metal-porphyrin-like graphenes for selective capture of carbon dioxide

    PubMed Central

    Bae, Hyeonhu; Park, Minwoo; Jang, Byungryul; Kang, Yura; Park, Jinwoo; Lee, Hosik; Chung, Haegeun; Chung, ChiHye; Hong, Suklyun; Kwon, Yongkyung; Yakobson, Boris I.; Lee, Hoonkyung

    2016-01-01

    Nanostructured materials, such as zeolites and metal-organic frameworks, have been considered to capture CO2. However, their application has been limited largely because they exhibit poor selectivity for flue gases and low capture capacity under low pressures. We perform a high-throughput screening for selective CO2 capture from flue gases by using first principles thermodynamics. We find that elements with empty d orbitals selectively attract CO2 from gaseous mixtures under low CO2 pressures (~10−3 bar) at 300 K and release it at ~450 K. CO2 binding to elements involves hybridization of the metal d orbitals with the CO2 π orbitals and CO2-transition metal complexes were observed in experiments. This result allows us to perform high-throughput screening to discover novel promising CO2 capture materials with empty d orbitals (e.g., Sc– or V–porphyrin-like graphene) and predict their capture performance under various conditions. Moreover, these findings provide physical insights into selective CO2 capture and open a new path to explore CO2 capture materials. PMID:26902156

  10. High-throughput screening of metal-porphyrin-like graphenes for selective capture of carbon dioxide.

    PubMed

    Bae, Hyeonhu; Park, Minwoo; Jang, Byungryul; Kang, Yura; Park, Jinwoo; Lee, Hosik; Chung, Haegeun; Chung, ChiHye; Hong, Suklyun; Kwon, Yongkyung; Yakobson, Boris I; Lee, Hoonkyung

    2016-02-23

    Nanostructured materials, such as zeolites and metal-organic frameworks, have been considered to capture CO2. However, their application has been limited largely because they exhibit poor selectivity for flue gases and low capture capacity under low pressures. We perform a high-throughput screening for selective CO2 capture from flue gases by using first principles thermodynamics. We find that elements with empty d orbitals selectively attract CO2 from gaseous mixtures under low CO2 pressures (~10(-3) bar) at 300 K and release it at ~450 K. CO2 binding to elements involves hybridization of the metal d orbitals with the CO2 π orbitals and CO2-transition metal complexes were observed in experiments. This result allows us to perform high-throughput screening to discover novel promising CO2 capture materials with empty d orbitals (e.g., Sc- or V-porphyrin-like graphene) and predict their capture performance under various conditions. Moreover, these findings provide physical insights into selective CO2 capture and open a new path to explore CO2 capture materials.

  11. High-throughput screening of metal-porphyrin-like graphenes for selective capture of carbon dioxide

    NASA Astrophysics Data System (ADS)

    Bae, Hyeonhu; Park, Minwoo; Jang, Byungryul; Kang, Yura; Park, Jinwoo; Lee, Hosik; Chung, Haegeun; Chung, Chihye; Hong, Suklyun; Kwon, Yongkyung; Yakobson, Boris I.; Lee, Hoonkyung

    2016-02-01

    Nanostructured materials, such as zeolites and metal-organic frameworks, have been considered to capture CO2. However, their application has been limited largely because they exhibit poor selectivity for flue gases and low capture capacity under low pressures. We perform a high-throughput screening for selective CO2 capture from flue gases by using first principles thermodynamics. We find that elements with empty d orbitals selectively attract CO2 from gaseous mixtures under low CO2 pressures (~10-3 bar) at 300 K and release it at ~450 K. CO2 binding to elements involves hybridization of the metal d orbitals with the CO2 π orbitals and CO2-transition metal complexes were observed in experiments. This result allows us to perform high-throughput screening to discover novel promising CO2 capture materials with empty d orbitals (e.g., Sc- or V-porphyrin-like graphene) and predict their capture performance under various conditions. Moreover, these findings provide physical insights into selective CO2 capture and open a new path to explore CO2 capture materials.

  12. A high-performance, flexible and robust metal nanotrough-embedded transparent conducting film for wearable touch screen panels

    NASA Astrophysics Data System (ADS)

    Im, Hyeon-Gyun; An, Byeong Wan; Jin, Jungho; Jang, Junho; Park, Young-Geun; Park, Jang-Ung; Bae, Byeong-Soo

    2016-02-01

    We report a high-performance, flexible and robust metal nanotrough-embedded transparent conducting hybrid film (metal nanotrough-GFRHybrimer). Using an electro-spun polymer nanofiber web as a template and vacuum-deposited gold as a conductor, a junction resistance-free continuous metal nanotrough network is formed. Subsequently, the metal nanotrough is embedded on the surface of a glass-fabric reinforced composite substrate (GFRHybrimer). The monolithic composite structure of our transparent conducting film allows simultaneously high thermal stability (24 h at 250 °C in air), a smooth surface topography (Rrms < 1 nm) and excellent opto-electrical properties. A flexible touch screen panel (TSP) is fabricated using the transparent conducting films. The flexible TSP device stably operates on the back of a human hand and on a wristband.We report a high-performance, flexible and robust metal nanotrough-embedded transparent conducting hybrid film (metal nanotrough-GFRHybrimer). Using an electro-spun polymer nanofiber web as a template and vacuum-deposited gold as a conductor, a junction resistance-free continuous metal nanotrough network is formed. Subsequently, the metal nanotrough is embedded on the surface of a glass-fabric reinforced composite substrate (GFRHybrimer). The monolithic composite structure of our transparent conducting film allows simultaneously high thermal stability (24 h at 250 °C in air), a smooth surface topography (Rrms < 1 nm) and excellent opto-electrical properties. A flexible touch screen panel (TSP) is fabricated using the transparent conducting films. The flexible TSP device stably operates on the back of a human hand and on a wristband. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07657a

  13. Case study: technology initiative led to advanced lead optimization screening processes at Bristol-Myers Squibb, 2004-2009.

    PubMed

    Zhang, Litao; Cvijic, Mary Ellen; Lippy, Jonathan; Myslik, James; Brenner, Stephen L; Binnie, Alastair; Houston, John G

    2012-07-01

    In this paper, we review the key solutions that enabled evolution of the lead optimization screening support process at Bristol-Myers Squibb (BMS) between 2004 and 2009. During this time, technology infrastructure investment and scientific expertise integration laid the foundations to build and tailor lead optimization screening support models across all therapeutic groups at BMS. Together, harnessing advanced screening technology platforms and expanding panel screening strategy led to a paradigm shift at BMS in supporting lead optimization screening capability. Parallel SAR and structure liability relationship (SLR) screening approaches were first and broadly introduced to empower more-rapid and -informed decisions about chemical synthesis strategy and to broaden options for identifying high-quality drug candidates during lead optimization. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Table screen 360-degree holographic display using circular viewing-zone scanning.

    PubMed

    Inoue, Tatsuaki; Takaki, Yasuhiro

    2015-03-09

    A table screen 360-degree holographic display is proposed, with an increased screen size, having an expanded viewing zone over all horizontal directions around the table screen. It consists of a microelectromechanical systems spatial light modulator (MEMS SLM), a magnifying imaging system, and a rotating screen. The MEMS SLM generates hologram patterns at a high frame rate, the magnifying imaging system increases the screen of the MEMS SLM, and the reduced viewing zones are scanned circularly by the rotating screen. The viewing zones are localized to practically realize wavefront reconstruction. An experimental system has been constructed. The generation of 360-degree three-dimensional (3D) images was achieved by scanning 800 reduced and localized viewing zones circularly. The table screen had a diameter of 100 mm, and the frame rate of 3D image generation was 28.4 Hz.

  15. Density functional theory based screening of ternary alkali-transition metal borohydrides: A computational material design project

    NASA Astrophysics Data System (ADS)

    Hummelshøj, J. S.; Landis, D. D.; Voss, J.; Jiang, T.; Tekin, A.; Bork, N.; Dułak, M.; Mortensen, J. J.; Adamska, L.; Andersin, J.; Baran, J. D.; Barmparis, G. D.; Bell, F.; Bezanilla, A. L.; Bjork, J.; Björketun, M. E.; Bleken, F.; Buchter, F.; Bürkle, M.; Burton, P. D.; Buus, B. B.; Calborean, A.; Calle-Vallejo, F.; Casolo, S.; Chandler, B. D.; Chi, D. H.; Czekaj, I.; Datta, S.; Datye, A.; DeLaRiva, A.; Despoja, V.; Dobrin, S.; Engelund, M.; Ferrighi, L.; Frondelius, P.; Fu, Q.; Fuentes, A.; Fürst, J.; García-Fuente, A.; Gavnholt, J.; Goeke, R.; Gudmundsdottir, S.; Hammond, K. D.; Hansen, H. A.; Hibbitts, D.; Hobi, E.; Howalt, J. G.; Hruby, S. L.; Huth, A.; Isaeva, L.; Jelic, J.; Jensen, I. J. T.; Kacprzak, K. A.; Kelkkanen, A.; Kelsey, D.; Kesanakurthi, D. S.; Kleis, J.; Klüpfel, P. J.; Konstantinov, I.; Korytar, R.; Koskinen, P.; Krishna, C.; Kunkes, E.; Larsen, A. H.; Lastra, J. M. G.; Lin, H.; Lopez-Acevedo, O.; Mantega, M.; Martínez, J. I.; Mesa, I. N.; Mowbray, D. J.; Mýrdal, J. S. G.; Natanzon, Y.; Nistor, A.; Olsen, T.; Park, H.; Pedroza, L. S.; Petzold, V.; Plaisance, C.; Rasmussen, J. A.; Ren, H.; Rizzi, M.; Ronco, A. S.; Rostgaard, C.; Saadi, S.; Salguero, L. A.; Santos, E. J. G.; Schoenhalz, A. L.; Shen, J.; Smedemand, M.; Stausholm-Møller, O. J.; Stibius, M.; Strange, M.; Su, H. B.; Temel, B.; Toftelund, A.; Tripkovic, V.; Vanin, M.; Viswanathan, V.; Vojvodic, A.; Wang, S.; Wellendorff, J.; Thygesen, K. S.; Rossmeisl, J.; Bligaard, T.; Jacobsen, K. W.; Nørskov, J. K.; Vegge, T.

    2009-07-01

    We present a computational screening study of ternary metal borohydrides for reversible hydrogen storage based on density functional theory. We investigate the stability and decomposition of alloys containing 1 alkali metal atom, Li, Na, or K (M1); and 1 alkali, alkaline earth or 3d/4d transition metal atom (M2) plus two to five (BH4)- groups, i.e., M1M2(BH4)2-5, using a number of model structures with trigonal, tetrahedral, octahedral, and free coordination of the metal borohydride complexes. Of the over 700 investigated structures, about 20 were predicted to form potentially stable alloys with promising decomposition energies. The M1(Al/Mn/Fe)(BH4)4, (Li/Na)Zn(BH4)3, and (Na/K)(Ni/Co)(BH4)3 alloys are found to be the most promising, followed by selected M1(Nb/Rh)(BH4)4 alloys.

  16. Evaluation of fuel additives for reduction of material imcompatibilities in methanol-gasoline blends

    NASA Technical Reports Server (NTRS)

    Rodriguez, C. F.; Barbee, J. G.; Knutson, W. K.; Cuellar, J. P., Jr.

    1983-01-01

    Screening tests determined the efficacy of six commercially available additives as modifiers of methanol's corrosivity toward metals and its weakening of tensile properties of nonmetals in automotive fuel systems. From the screening phase, three additives which seemed to protect some of the metals were tested in higher concentrations and binary combinations in search of optimal application conditions. Results indicate that two of the additives have protective properties and combining them increases the protection of the metals corroded by methanol-gasoline blends. Half of the metals in the tests were not corroded. Testing at recommended concentrations and then at higher concentrations and in combinations shows that the additives would have no protective or harmful effects on the nonmetals. Two additives emerged as candidates for application to the protection of metals in automotive methanol-gasoline fuel systems. The additives tested were assigned letter codes to protect their proprietary nature.

  17. Metal artifact reduction for CT-based luggage screening.

    PubMed

    Karimi, Seemeen; Martz, Harry; Cosman, Pamela

    2015-01-01

    In aviation security, checked luggage is screened by computed tomography scanning. Metal objects in the bags create artifacts that degrade image quality. Though there exist metal artifact reduction (MAR) methods mainly in medical imaging literature, they require knowledge of the materials in the scan, or are outlier rejection methods. To improve and evaluate a MAR method we previously introduced, that does not require knowledge of the materials in the scan, and gives good results on data with large quantities and different kinds of metal. We describe in detail an optimization which de-emphasizes metal projections and has a constraint for beam hardening and scatter. This method isolates and reduces artifacts in an intermediate image, which is then fed to a previously published sinogram replacement method. We evaluate the algorithm for luggage data containing multiple and large metal objects. We define measures of artifact reduction, and compare this method against others in MAR literature. Metal artifacts were reduced in our test images, even for multiple and large metal objects, without much loss of structure or resolution. Our MAR method outperforms the methods with which we compared it. Our approach does not make assumptions about image content, nor does it discard metal projections.

  18. Handheld colorimeter for determination of heavy metal concentrations

    NASA Astrophysics Data System (ADS)

    López Ruiz, N.; Ariza, M.; Martínez Olmos, A.; Vukovic, J.; Palma, A. J.; Capitan-Vallvey, L. F.

    2011-08-01

    A portable instrument that measures heavy metal concentration from a colorimetric sensor array is presented. The use of eight sensing membranes, placed on a plastic support, allows to obtain the hue component of the HSV colour space of each one in order to determinate the concentration of metals present in a solution. The developed microcontroller-based system captures, in an ambient light environment, an image of the sensor array using an integrated micro-camera and shows the picture in a touch micro-LCD screen which acts as user interface. After image-processing of the regions of interest selected by the user, colour and concentration information are displayed on the screen.

  19. The Packing of Helical and Zigzag Chains and Distribution of Interstitial Voids in Expanded Liquid Se near the Semiconductor to Metal Transition

    NASA Astrophysics Data System (ADS)

    Maruyama, Kenji; Hiroi (Sato), Satoshi; Endo, Hirohisa; Hoshino, Hideoki; Odagaki, Takashi; Hensel, Friedrich

    2017-08-01

    The reverse Monte Carlo (RMC) and Voronoi-Delaunay (VD) void analyses were applied to study the modification of chain geometries near the semiconductor (SC) to metal (M) transition in expanded liquid Se along the isochore of d = 3.4 g/cm3. Fluctuations of dihedral angles with increasing temperature and pressure cause modification of the helical (H) chain to the planar zigzag (Z) chain conformations. The distribution of voids size (rV ) supported by chain segments and distances to the 4th 6th neighbor atoms on the chain segments provide information on the stacking of planar zigzag chains compensated by empty space (L-voids, rV 3.6 Å) which leads to the formation of metallic domains. Near SC-M transition region the number fraction NZ/NH for Z and H chain segments increases.

  20. Managing malignant biliary obstruction in pancreas cancer: Choosing the appropriate strategy

    PubMed Central

    Boulay, Brian R; Parepally, Mayur

    2014-01-01

    Most patients with pancreatic cancer develop malignant biliary obstruction. Treatment of obstruction is generally indicated to relieve symptoms and improve morbidity and mortality. First-line therapy consists of endoscopic biliary stent placement. Recent data comparing plastic stents to self-expanding metallic stents (SEMS) has shown improved patency with SEMS. The decision of whether to treat obstruction and the means for doing so depends on the clinical scenario. For patients with resectable disease, preoperative biliary decompression is only indicated when surgery will be delayed or complications of jaundice exist. For patients with locally advanced disease, self-expanding metal stents are superior to plastic stents for long-term patency. For patients with advanced disease, the choice of metallic or plastic stent depends on life expectancy. When endoscopic stent placement fails, percutaneous or surgical treatments are appropriate. Endoscopic therapy or surgical approach can be used to treat concomitant duodenal and biliary obstruction. PMID:25071329

  1. Internal stenting in malignant biliary obstruction.

    PubMed

    Cowling, M G; Adam, A N

    2001-03-01

    Internal stenting in inoperable malignant biliary obstruction plays an important role in patient management. Surgical bypass may still be undertaken where there is also duodenal obstruction, though the need for gastroenterostomy may be reduced with the increasing use of metallic stents for the relief of malignant gastric outlet obstruction. Stents may be placed endoscopically or percutaneously, though in most centers the endoscopic route is usually tried first, with the percutaneous route being reserved for endoscopic failures. Plastic and self-expanding metallic biliary stents are available, each with its own advantages and disadvantages. In general, longer periods of patency are observed with metallic stents, though they are more expensive. Plastic stents can be changed endoscopically relatively easily when they have blocked, and in practice it is common for plastic stents to be inserted via this route for initial biliary drainage. If there is prolonged survival thereafter, many workers insert a metallic stent in an attempt to reduce the number of interventions required. If the percutaneous route is being employed, the histologic diagnosis has been confirmed, and the malignancy is inoperable, our practice is to use a self-expanding metallic stent, as the delivery system is relatively small and subsequent occlusion less likely.

  2. Prediction of a native ferroelectric metal

    PubMed Central

    Filippetti, Alessio; Fiorentini, Vincenzo; Ricci, Francesco; Delugas, Pietro; Íñiguez, Jorge

    2016-01-01

    Over 50 years ago, Anderson and Blount discussed symmetry-allowed polar distortions in metals, spawning the idea that a material might be simultaneously metallic and ferroelectric. While many studies have ever since considered such or similar situations, actual ferroelectricity—that is, the existence of a switchable intrinsic electric polarization—has not yet been attained in a metal, and is in fact generally deemed incompatible with the screening by mobile conduction charges. Here we refute this common wisdom and show, by means of first-principles simulations, that native metallicity and ferroelectricity coexist in the layered perovskite Bi5Ti5O17. We show that, despite being a metal, Bi5Ti5O17 can sustain a sizable potential drop along the polar direction, as needed to reverse its polarization by an external bias. We also reveal striking behaviours, as the self-screening mechanism at work in thin Bi5Ti5O17 layers, emerging from the interplay between polar distortions and carriers in this compound. PMID:27040076

  3. Alternative Fuels Data Center: Video Download Help

    Science.gov Websites

    a Windows Media Video (WMV) link and select "Save Target As..." from the shortcut menu. To player on the screen. You can also expand the video to play in full-screen mode using Windows Media played in Windows Media Player. Download Windows Media Player. To watch videos on a Mac, double-click the

  4. Advancing Early Detection of Autism Spectrum Disorder by Applying an Integrated Two-Stage Screening Approach

    ERIC Educational Resources Information Center

    Oosterling, Iris J.; Wensing, Michel; Swinkels, Sophie H.; van der Gaag, Rutger Jan; Visser, Janne C.; Woudenberg, Tim; Minderaa, Ruud; Steenhuis, Mark-Peter; Buitelaar, Jan K.

    2010-01-01

    Background: Few field trials exist on the impact of implementing guidelines for the early detection of autism spectrum disorders (ASD). The aims of the present study were to develop and evaluate a clinically relevant integrated early detection programme based on the two-stage screening approach of Filipek et al. (1999), and to expand the evidence…

  5. Field tests of nylon-screen diffusion samplers and pushpoint samplers for detection of metals in sediment pore water, Ashland and Clinton, Massachusetts, 2003

    USGS Publications Warehouse

    Zimmerman, Marc J.; Vroblesky, Don A.; Campo, Kimberly W.; Massey, Andrew J.; Scheible, Walter

    2005-01-01

    Efficient and economical screening methods are needed to detect and to determine the approximate concentrations of potentially toxic trace-element metals in shallow groundwater- discharge areas (pore water) where the metals may pose threats to aquatic organisms; such areas are likely to be near hazardous-waste sites. Pushpoint and nylon-screen diffusion samplers are two complementary options for use in such environments. The pushpoint sampler, a simple well point, is easy to insert manually and to use. Only 1 day is required to collect samples. The nylon-screen diffusion sampler is well suited for use in sediments that do not allow a pump to draw water into a pushpoint sampler. In this study, both types of devices were used in sediments suitable for the use of the pushpoint sampler. Sampling with the nylon-screen diffusion sampler requires at least two site visits: one to deploy the samplers in the sediment, and a second to retrieve the samplers and collect the samples after a predetermined equilibration period. Extensive laboratory quality-control studies, field testing, and laboratory analysis of samples collected at the Nyanza Chemical Waste Dump Superfund site along the Sudbury River in Ashland, Massachusetts, and at a Superfund site-assessment location on Rigby Brook in Clinton, Massachusetts, indicate that these two devices yield comparable results for most metals and should be effective tools for pore-water studies. The nylon-screen diffusion samplers equilibrated within 1-2 days in homogeneous, controlled conditions in the laboratory. Nylon-screen diffusion samplers that were not purged of dissolved oxygen prior to deployment yielded results similar to those that were purged. Further testing of the nylon-screen diffusion samplers in homogeneous media would help to resolve any ambiguities about the data variability from the field studies. Comparison of data from replicate samples taken in both study areas shows that even samples taken from sites within a half-meter radius of one another have distinct differences in pore-water trace-element concentrations. Sequential replicate samples collected with the pushpoint sampler yield consistent results; moving the pushpoint sampler even 5 to 10 centimeters, however, generally produces a second set of data that differs enough from the first set of data to indicate a heterogeneous environment. High concentration biases for barium and zinc in laboratory and field samples collected with nylon-screen diffusion samplers, however, may make their use inappropriate for studies of these metals. Analyzing samples with high iron concentrations required sample dilution by factors of 2 or 10. Because these dilutions caused increases in the reporting levels by the same proportion, a substantial fraction of the data was censored. The results from undiluted samples, however, indicate that both devices should be useful for sampling ground water with metal concentrations close to reporting limits.

  6. Evaluation of environmental magnetic pollution screening in soils of basaltic origin: results from Nashik Thermal Power Station, Maharashtra, India.

    PubMed

    Basavaiah, N; Blaha, U; Das, P K; Deenadayalan, K; Sadashiv, M B; Schulz, H

    2011-08-01

    Soils of basaltic origin cause difficulties in environmental magnetic screening for heavy metal pollution due to their natural high background values. Magnetic parameters and heavy metal content of highly magnetic topsoils from the Deccan Trap basalts are investigated to assess their potential for use in environmental magnetic pollution screening. This work extends the fast and cost-effective magnetic pollution screening techniques into soils with high natural magnetic signals. Fifty-five topsoil samples from N-S and W-E transects were collected and subdivided according to grain size using wet sieving technique. Magnetic susceptibility, soft isothermal remanent magnetization (Soft IRM), thermomagnetic analysis, scanning electron microscopy (SEM), and heavy metal analysis were performed on the samples. Magnetic analyses reveal a significant input of anthropogenic magnetic particulate matter within 6 km of the power plant and the adjacent ash pond. Results depend strongly on the stage of soil development and vary spatially. While results in the W, E, and S directions are easily interpretable, in the N direction, the contribution of the anthropogenic magnetic matter is difficult to assess due to high magnetic background values, less developed soils, and a more limited contribution from the fly ash sources. Prevailing winds towards directions with more enhanced values seem to have a certain effect on particulate matter accumulation in the topsoil. Thermomagnetic measurements show Verwey transition and Hopkinson peak, thus proving the presence of ferrimagnetic mineral phases close to the pollution source. A quantitative decrease of the anthropogenic ferrimagnetic mineral concentration with increased distance is evident in Soft IRM measurements. SEM investigations of quantitatively extracted magnetic particles confirm the fly ash distribution pattern obtained from the magnetic and heavy metal analyses. Evaluation of magnetic and chemical data in concert with the Pollution Load IndiceS (PLIS) of Pb, Zn, and Cu reveals a good relationship between magnetic susceptibility and the metal content. Integrated approaches in data acquisition of magnetic and chemical parameters enable the application of magnetic screening methods in highly magnetic soils. Combined data evaluation allows identification of sampling sites that are affected by human activity, through the deviation of the magnetic and chemical data from the general trend. It is shown that integrative analysis of magnetic parameters and a limited metal concentration dataset can enhance the quality of the output of environmental magnetic pollution screening significantly.

  7. Evaluation and Design of Genome-Wide CRISPR/SpCas9 Knockout Screens

    PubMed Central

    Hart, Traver; Tong, Amy Hin Yan; Chan, Katie; Van Leeuwen, Jolanda; Seetharaman, Ashwin; Aregger, Michael; Chandrashekhar, Megha; Hustedt, Nicole; Seth, Sahil; Noonan, Avery; Habsid, Andrea; Sizova, Olga; Nedyalkova, Lyudmila; Climie, Ryan; Tworzyanski, Leanne; Lawson, Keith; Sartori, Maria Augusta; Alibeh, Sabriyeh; Tieu, David; Masud, Sanna; Mero, Patricia; Weiss, Alexander; Brown, Kevin R.; Usaj, Matej; Billmann, Maximilian; Rahman, Mahfuzur; Costanzo, Michael; Myers, Chad L.; Andrews, Brenda J.; Boone, Charles; Durocher, Daniel; Moffat, Jason

    2017-01-01

    The adaptation of CRISPR/SpCas9 technology to mammalian cell lines is transforming the study of human functional genomics. Pooled libraries of CRISPR guide RNAs (gRNAs) targeting human protein-coding genes and encoded in viral vectors have been used to systematically create gene knockouts in a variety of human cancer and immortalized cell lines, in an effort to identify whether these knockouts cause cellular fitness defects. Previous work has shown that CRISPR screens are more sensitive and specific than pooled-library shRNA screens in similar assays, but currently there exists significant variability across CRISPR library designs and experimental protocols. In this study, we reanalyze 17 genome-scale knockout screens in human cell lines from three research groups, using three different genome-scale gRNA libraries. Using the Bayesian Analysis of Gene Essentiality algorithm to identify essential genes, we refine and expand our previously defined set of human core essential genes from 360 to 684 genes. We use this expanded set of reference core essential genes, CEG2, plus empirical data from six CRISPR knockout screens to guide the design of a sequence-optimized gRNA library, the Toronto KnockOut version 3.0 (TKOv3) library. We then demonstrate the high effectiveness of the library relative to reference sets of essential and nonessential genes, as well as other screens using similar approaches. The optimized TKOv3 library, combined with the CEG2 reference set, provide an efficient, highly optimized platform for performing and assessing gene knockout screens in human cell lines. PMID:28655737

  8. Terrestrial Eco-Toxicological Tests as Screening Tool to Assess Soil Contamination in Krompachy Area

    NASA Astrophysics Data System (ADS)

    Ol'ga, Šestinová; Findoráková, Lenka; Hančuľák, Jozef; Fedorová, Erika; Tomislav, Špaldon

    2016-10-01

    In this study, we present screening tool of heavy metal inputs to agricultural and permanent grass vegetation of the soils in Krompachy. This study is devoted to Ecotoxicity tests, Terrestrial Plant Test (modification of OECD 208, Phytotoxkit microbiotest on Sinapis Alba) and chronic tests of Earthworm (Dendrobaena veneta, modification of OECD Guidelines for the testing of chemicals 317, Bioaccumulation in Terrestrial Oligochaetes) as practical and sensitive screening method for assessing the effects of heavy metals in Krompachy soils. The total Cu, Zn, As, Pb and Hg concentrations and eco-toxicological tests of soils from the Krompachy area were determined of 4 sampling sites in 2015. An influence of the sampling sites distance from the copper smeltery on the absolutely concentrations of metals were recorded for copper, lead, zinc, arsenic and mercury. The highest concentrations of these metals were detected on the sampling sites up to 3 km from the copper smeltery. The samples of soil were used to assess of phytotoxic effect. Total mortality was established at earthworms using chronic toxicity test after 7 exposure days. The results of our study confirmed that no mortality was observed in any of the study soils. Based on the phytotoxicity testing, phytotoxic effects of the metals contaminated soils from the samples 3KR (7-9) S.alba seeds was observed.

  9. Refined Dummy Atom Model of Mg(2+) by Simple Parameter Screening Strategy with Revised Experimental Solvation Free Energy.

    PubMed

    Jiang, Yang; Zhang, Haiyang; Feng, Wei; Tan, Tianwei

    2015-12-28

    Metal ions play an important role in the catalysis of metalloenzymes. To investigate metalloenzymes via molecular modeling, a set of accurate force field parameters for metal ions is highly imperative. To extend its application range and improve the performance, the dummy atom model of metal ions was refined through a simple parameter screening strategy using the Mg(2+) ion as an example. Using the AMBER ff03 force field with the TIP3P model, the refined model accurately reproduced the experimental geometric and thermodynamic properties of Mg(2+). Compared with point charge models and previous dummy atom models, the refined dummy atom model yields an enhanced performance for producing reliable ATP/GTP-Mg(2+)-protein conformations in three metalloenzyme systems with single or double metal centers. Similar to other unbounded models, the refined model failed to reproduce the Mg-Mg distance and favored a monodentate binding of carboxylate groups, and these drawbacks needed to be considered with care. The outperformance of the refined model is mainly attributed to the use of a revised (more accurate) experimental solvation free energy and a suitable free energy correction protocol. This work provides a parameter screening strategy that can be readily applied to refine the dummy atom models for metal ions.

  10. Direct water decomposition on transition metal surfaces: Structural dependence and catalytic screening

    DOE PAGES

    Tsai, Charlie; Lee, Kyoungjin; Yoo, Jong Suk; ...

    2016-02-16

    Density functional theory calculations are used to investigate thermal water decomposition over the close-packed (111), stepped (211), and open (100) facets of transition metal surfaces. A descriptor-based approach is used to determine that the (211) facet leads to the highest possible rates. As a result, a range of 96 binary alloys were screened for their potential activity and a rate control analysis was performed to assess how the overall rate could be improved.

  11. Wick for metal vapor laser

    DOEpatents

    Duncan, David B.

    1992-01-01

    An improved wick for a metal vapor laser is made of a refractory metal cylinder, preferably molybdenum or tungsten for a copper laser, which provides the wicking surface. Alternately, the inside surface of the ceramic laser tube can be metalized to form the wicking surface. Capillary action is enhanced by using wire screen, porous foam metal, or grooved surfaces. Graphite or carbon, in the form of chunks, strips, fibers or particles, is placed on the inside surface of the wick to reduce water, reduce metal oxides and form metal carbides.

  12. Comparison of the utility of covered metal stents versus uncovered metal stents in the management of malignant biliary strictures in 749 patients.

    PubMed

    Lee, Jeffrey H; Krishna, Somashekar G; Singh, Amanpal; Ladha, Harshad S; Slack, Rebecca S; Ramireddy, Srinivas; Raju, Gottumukkala S; Davila, Marta; Ross, William A

    2013-08-01

    Self-expandable metal stents (SEMSs) are used to relieve malignant biliary obstruction. To compare outcomes between covered self-expandable metal stents (CSEMSs) and uncovered self-expandable metal stents (USEMSs) in malignant biliary obstruction. Retrospective cohort study. Tertiary cancer center. Patients with malignant biliary obstruction. Placement of CSEMS or USEMS. Time to recurrent biliary obstruction (TRO), overall survival (OS), and adverse events. From January 2000 to June 2011, 749 patients received SEMSs: 171 CSEMSs and 578 USEMSs. At 1 year, there was no significant difference in the percentage of patients with recurrent obstruction (CSEMSs, 35% vs USEMSs, 38%) and survival (CSEMSs, 45% vs USEMSs, 49%). There was no significant difference in the median OS (CSEMSs, 10.4 months vs USEMSs, 11.8 months; P = .84) and the median TRO (CSEMSs, 15.4 months vs USEMSs, 26.3 months; P = .61). The adverse event rate was 27.5% for the CSEMS group and 27.7% for the USEMS group. Although tumor ingrowth with recurrent obstruction was more common in the USEMS group (76% vs 9%, P < .001), stent migration (36% vs 2%, P < .001) and acute pancreatitis (6% vs 1%, P < .001) were more common in the CSEMS group. Retrospective study. There was no significant difference in the patency rate or overall survival between CSEMSs and USEMSs for malignant distal biliary strictures. The CSEMS group had a significantly higher rate of migration and pancreatitis than the USEMS group. No significant SEMS-related adverse events were observed in patients undergoing neoadjuvant chemoradiation or surgical resection. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  13. Self-expanding metal stents for treatment of anastomotic complications after colorectal resection.

    PubMed

    Lamazza, A; Fiori, E; De Masi, E; Scoglio, D; Sterpetti, A V; Lezoche, E

    2013-06-01

    Self-expanding metal stents (SEMS) can be used to treat patients with symptomatic anastomotic complications after colorectal resection. In the present case series, 16 patients with symptomatic anastomotic stricture after colorectal resection were treated with endoscopic placement of SEMS. Seven patients had a "simple" anastomotic stricture and nine patients had a fistula associated with the stricture. The anastomotic fistula healed without evidence of residual stricture or major fecal incontinence in seven of the nine patients. Overall the anastomotic stricture was resolved in 10 of the 16 patients. SEMS placement represents a valid adjunctive to treatment in patients with symptomatic anastomotic complications after colorectal resection for cancer. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Recovery and validation of historical sediment quality data from coastal and estuarine areas: An integrated approach

    USGS Publications Warehouse

    Manheim, F.T.; Buchholtz ten Brink, Marilyn R.; Mecray, E.L.

    1998-01-01

    A comprehensive database of sediment chemistry and environmental parameters has been compiled for Boston Harbor and Massachusetts Bay. This work illustrates methodologies for rescuing and validating sediment data from heterogeneous historical sources. It greatly expands spatial and temporal data coverage of estuarine and coastal sediments. The database contains about 3500 samples containing inorganic chemical, organic, texture and other environmental data dating from 1955 to 1994. Cooperation with local and federal agencies as well as universities was essential in locating and screening documents for the database. More than 80% of references utilized came from sources with limited distribution (gray literature). Task sharing was facilitated by a comprehensive and clearly defined data dictionary for sediments. It also served as a data entry template and flat file format for data processing and as a basis for interpretation and graphical illustration. Standard QA/QC protocols are usually inapplicable to historical sediment data. In this work outliers and data quality problems were identified by batch screening techniques that also provide visualizations of data relationships and geochemical affinities. No data were excluded, but qualifying comments warn users of problem data. For Boston Harbor, the proportion of irreparable or seriously questioned data was remarkably small (<5%), although concentration values for metals and organic contaminants spanned 3 orders of magnitude for many elements or compounds. Data from the historical database provide alternatives to dated cores for measuring changes in surficial sediment contamination level with time. The data indicate that spatial inhomogeneity in harbor environments can be large with respect to sediment-hosted contaminants. Boston Inner Harbor surficial sediments showed decreases in concentrations of Cu, Hg, and Zn of 40 to 60% over a 17-year period.A comprehensive database of sediment chemistry and environmental parameters has been compiled for Boston Harbor and Massachusetts Bay. This work illustrates methodologies for rescuing and validating sediment data from heterogeneous historical sources. It greatly expands spatial and temporal data coverage of estuarine and coastal sediments. The database contains about 3500 samples containing inorganic chemical, organic, texture and other environmental data dating from 1995 to 1994. Cooperation with local and federal agencies as well as universities was essential in locating and screening documents for the database. More than 80% of references utilized came from sources with limited distribution (gray Task sharing was facilitated by a comprehensive and clearly defined data dictionary for sediments. It also served as a data entry template and flat file format for data processing and as a basis for interpretation and graphical illustration. Standard QA/QC protocols are usually inapplicable to historical sediment data. In this work outliers and data quality problems were identified by batch screening techniques that also provide visualizations of data relationships and geochemical affinities. No data were excluded, but qualifying comments warn users of problem data. For Boston Harbor, the proportion of irreparable or seriously questioned data was remarkably small (<5%), although concentration values for metals and organic contaminants spanned 3 orders of magnitude for many elements or compounds. Data from the historical database provide alternatives to dated cores for measuring changes in surficial sediment contamination level with time. The data indicate that spatial inhomogeneity in harbor environments can be large with respect to sediment-hosted contaminants. Boston Inner Harbor surficial sediments showed decreases in concentrations Cu, Hg, and Zn of 40 to 60% over a 17-year period.

  15. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Ye Jin; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Song, Ho-Young

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients couldmore » eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10-119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.« less

  16. A Simple, High-Throughput Assay for Fragile X Expanded Alleles Using Triple Repeat Primed PCR and Capillary Electrophoresis

    PubMed Central

    Lyon, Elaine; Laver, Thomas; Yu, Ping; Jama, Mohamed; Young, Keith; Zoccoli, Michael; Marlowe, Natalia

    2010-01-01

    Population screening has been proposed for Fragile X syndrome to identify premutation carrier females and affected newborns. We developed a PCR-based assay capable of quickly detecting the presence or absence of an expanded FMR1 allele with high sensitivity and specificity. This assay combines a triplet repeat primed PCR with high-throughput automated capillary electrophoresis. We evaluated assay performance using archived samples sent for Fragile X diagnostic testing representing a range of Fragile X CGG-repeat expansions. Two hundred five previously genotyped samples were tested with the new assay. Data were analyzed for the presence of a trinucleotide “ladder” extending beyond 55 repeats, which was set as a cut-off to identify expanded FMR1 alleles. We identified expanded FMR1 alleles in 132 samples (59 premutation, 71 full mutation, 2 mosaics) and normal FMR1 alleles in 73 samples. We found 100% concordance with previous results from PCR and Southern blot analyses. In addition, we show feasibility of using this assay with DNA extracted from dried-blood spots. Using a single PCR combined with high-throughput fragment analysis on the automated capillary electrophoresis instrument, we developed a rapid and reproducible PCR-based laboratory assay that meets many of the requirements for a first-tier test for population screening. PMID:20431035

  17. 78 FR 76860 - Contraband Screening for Criminal Justice Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-19

    ... detection (e.g., transmission x-ray, active millimeter wave). 3. Size Class of the system/device: Fixed... traditional metal detectors will also be accepted. The NIJ Sensor, Surveillance and Biometric Technologies.... Whether the system/device Detects Metal objects. a. If YES, whether there are any types of metals that are...

  18. High-Throughput Screening and Quantitative Chemical Ranking for Sodium-Iodide Symporter Inhibitors in ToxCast Phase I Chemical Library.

    PubMed

    Wang, Jun; Hallinger, Daniel R; Murr, Ashley S; Buckalew, Angela R; Simmons, Steven O; Laws, Susan C; Stoker, Tammy E

    2018-05-01

    Thyroid uptake of iodide via the sodium-iodide symporter (NIS) is the first step in the biosynthesis of thyroid hormones that are critical for health and development in humans and wildlife. Despite having long been a known target of endocrine disrupting chemicals such as perchlorate, information regarding NIS inhibition activity is still unavailable for the vast majority of environmental chemicals. This study applied a previously validated high-throughput approach to screen for NIS inhibitors in the ToxCast phase I library, representing 293 important environmental chemicals. Here 310 blinded samples were screened in a tiered-approach using an initial single-concentration (100 μM) radioactive-iodide uptake (RAIU) assay, followed by 169 samples further evaluated in multi-concentration (0.001 μM-100 μM) testing in parallel RAIU and cell viability assays. A novel chemical ranking system that incorporates multi-concentration RAIU and cytotoxicity responses was also developed as a standardized method for chemical prioritization in current and future screenings. Representative chemical responses and thyroid effects of high-ranking chemicals are further discussed. This study significantly expands current knowledge of NIS inhibition potential in environmental chemicals and provides critical support to U.S. EPA's Endocrine Disruptor Screening Program (EDSP) initiative to expand coverage of thyroid molecular targets, as well as the development of thyroid adverse outcome pathways (AOPs).

  19. Modeling of the metallic port in breast tissue expanders for photon radiotherapy.

    PubMed

    Yoon, Jihyung; Xie, Yibo; Heins, David; Zhang, Rui

    2018-03-30

    The purpose of this study was to model the metallic port in breast tissue expanders and to improve the accuracy of dose calculations in a commercial photon treatment planning system (TPS). The density of the model was determined by comparing TPS calculations and ion chamber (IC) measurements. The model was further validated and compared with two widely used clinical models by using a simplified anthropomorphic phantom and thermoluminescent dosimeters (TLD) measurements. Dose perturbations and target coverage for a single postmastectomy radiotherapy (PMRT) patient were also evaluated. The dimensions of the metallic port model were determined to be 1.75 cm in diameter and 5 mm in thickness. The density of the port was adjusted to be 7.5 g/cm 3 which minimized the differences between IC measurements and TPS calculations. Using the simplified anthropomorphic phantom, we found the TPS calculated point doses based on the new model were in agreement with TLD measurements within 5.0% and were more accurate than doses calculated based on the clinical models. Based on the photon treatment plans for a real patient, we found that the metallic port has a negligible dosimetric impact on chest wall, while the port introduced significant dose shadow in skin area. The current clinical port models either overestimate or underestimate the attenuation from the metallic port, and the dose perturbation depends on the plan and the model in a complex way. TPS calculations based on our model of the metallic port showed good agreement with measurements for all cases. This new model could improve the accuracy of dose calculations for PMRT patients who have temporary tissue expanders implanted during radiotherapy and could potentially reduce the risk of complications after the treatment. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  20. Placement of retrievable self-expandable metallic stents with barbs into patients with obstructive prostate cancer.

    PubMed

    Song, Ho-Young; Kim, Choung Soo; Jeong, In Gab; Yoo, Dalsan; Kim, Jin Hyoung; Nam, Deok Ho; Bae, Jae-Ik; Park, Jung-Hoon

    2013-03-01

    To evaluate the technical feasibility and clinical effectiveness of retrievable self-expandable metallic stents with barbs in patients with obstructive prostate cancer. Retrievable self-expandable metallic stents with eight barbs each were inserted into eight consecutive patients with obstructive prostate cancer. Patient ages ranged from 55 to 76 years (mean, 69 years). All eight patients had previously received hormone therapy, and three had undergone palliative transurethral prostatectomy. Stents were removed using a 21-F stent removal set if they caused complications. Stent placement was technically successful and well tolerated in all patients. One had severe incontinence, which improved spontaneously, and two had gross haematuria, which disappeared spontaneously within 4 days. Peak urine flow rates and post-void residual urine volumes 1 month after stent placement were 5.6-10.2 ml/s (mean, 8.3 ml/s), and 5-45 ml (mean, 27 ml), respectively. During a mean follow-up of 192 days (range, 39-632 days), one patient required stent removal after 232 days because of stone formation within the stent. No further intervention was required because the mass improved after stent removal. These preliminary results suggest that retrievable stents with eight barbs are both feasible to place and effective in patients with obstructive prostate cancer.

  1. Predictors of the patency of self-expandable metallic stents in malignant gastroduodenal obstruction

    PubMed Central

    Kim, Seung Han; Chun, Hoon Jai; Yoo, In Kyung; Lee, Jae Min; Nam, Seung Joo; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck

    2015-01-01

    AIM: To investigate the predictive factors of self-expandable metallic stent patency after stent placement in patients with inoperable malignant gastroduodenal obstruction. METHODS: A total of 116 patients underwent stent placements for inoperable malignant gastroduodenal obstruction at a tertiary academic center. Clinical success was defined as acceptable decompression of the obstructive lesion within the malignant gastroduodenal neoplasm. We evaluated patient comorbidities and clinical statuses using the World Health Organization’s scoring system and categorized patient responses to chemotherapy using the Response Evaluation Criteria in Solid Tumors criteria. We analyzed the relationships between possible predictive factors and stent patency. RESULTS: Self-expandable metallic stent placement was technically successful in all patients (100%), and the clinical success rate was 84.2%. In a multivariate Cox proportional hazards model, carcinoembryonic antigen (CEA) levels were correlated with a reduction in stent patency [P = 0.006; adjusted hazard ratio (aHR) = 2.92, 95%CI: 1.36-6.25]. Palliative chemotherapy was statistically associated with an increase in stent patency (P = 0.009; aHR = 0.27, 95%CI: 0.10-0.72). CONCLUSION: CEA levels can easily be measured at the time of stent placement and may help clinicians to predict stent patency and determine the appropriate stent procedure. PMID:26290640

  2. A pilot study about the oncologic safety of colonic self-expandable metal stents (SEMS) in obstructive colon cancer: is occlusion always better than "silent" perforation?

    PubMed

    Zanghì, A; Piccolo, G; Cavallaro, A; Pulvirenti, E; Lo Menzo, E; Cardì, F; Di Vita, M; Cappellani, A

    2016-12-01

    To evaluate the oncologic safety of colonic self-expandable metal stents (SEMS) in obstructive colon cancer. We retrospectively reviewed all the patients who were treated with endoscopic placement of a self-expandable metallic stent (SEMS) at our institution. A total of 26 patients were identified during the study period, of which 24 patients (92.30%) were treated with SEMS as a bridge-to-surgery and 2 (7.69%) as palliation. In 22 cases (80.76%), the stenosis was localized to the left side. Clinical success with resolution of bowel obstructions was achieved in 22 (84.61%) patients within a short period of time. Among patients treated successfully with SEMS insertion as bridge to surgery (n = 22), 20 (90.9%) underwent one-stage surgery with primary anastomosis while 2 patients (9.09%) underwent colostomy due to intraoperative evidence of a covered perforation by cancer tissue in the pelvis. Patients with subclinical perforation developed an early peritoneal carcinomatosis, 10 patients treated with curative intent subsequently developed liver metastasis after 24 months. We reported an overall poor outcome among patients treated with the insertion of SEMS. This led us to think that, in some cases, occlusion may be better than a "silent" perforation.

  3. Current collector for AMTEC

    NASA Technical Reports Server (NTRS)

    Williams, Roger M. (Inventor)

    1989-01-01

    An electrode having higher power output is formed of an open mesh current collector such as expanded nickel covering an electrode film applied to a tube of beta-alumina solid electrolyte (BASE). A plurality of cross-members such as spaced, parallel loops of molybdenum metal wire surround the BASE tube. The loops are electrically connected by a bus wire. As the AMTEC cell is heated, the grid of expanded nickel expands more than the BASE tube and the surrounding loop of wire and become diffusion welded to the electrode film and to the wire loops.

  4. Higher Order Multipole Potentials and Electrostatic Screening Effects on Cohesive Energy and Bulk Modulus of Metallic Nanoparticles

    NASA Astrophysics Data System (ADS)

    Barakat, T.

    2011-12-01

    Higher order multipole potentials and electrostatic screening effects are introduced to incorporate the dangling bonds on the surface of a metallic nanopaticle and to modify the coulomb like potential energy terms, respectively. The total interaction energy function for any metallic nanoparticle is represented in terms of two- and three-body potentials. The two-body part is described by dipole-dipole interaction potential, and in the three-body part, triple-dipole (DDD) and dipole-dipole-quadrupole (DDQ) terms are included. The size-dependent cohesive energy and bulk modulus are observed to decrease with decreasing sizes, a result which is in good agreement with the experimental values of Mo and W nanoparticles.

  5. Extending enzyme molecular recognition with an expanded amino acid alphabet

    PubMed Central

    Windle, Claire L.; Simmons, Katie J.; Ault, James R.; Trinh, Chi H.; Nelson, Adam

    2017-01-01

    Natural enzymes are constructed from the 20 proteogenic amino acids, which may then require posttranslational modification or the recruitment of coenzymes or metal ions to achieve catalytic function. Here, we demonstrate that expansion of the alphabet of amino acids can also enable the properties of enzymes to be extended. A chemical mutagenesis strategy allowed a wide range of noncanonical amino acids to be systematically incorporated throughout an active site to alter enzymic substrate specificity. Specifically, 13 different noncanonical side chains were incorporated at 12 different positions within the active site of N-acetylneuraminic acid lyase (NAL), and the resulting chemically modified enzymes were screened for activity with a range of aldehyde substrates. A modified enzyme containing a 2,3-dihydroxypropyl cysteine at position 190 was identified that had significantly increased activity for the aldol reaction of erythrose with pyruvate compared with the wild-type enzyme. Kinetic investigation of a saturation library of the canonical amino acids at the same position showed that this increased activity was not achievable with any of the 20 proteogenic amino acids. Structural and modeling studies revealed that the unique shape and functionality of the noncanonical side chain enabled the active site to be remodeled to enable more efficient stabilization of the transition state of the reaction. The ability to exploit an expanded amino acid alphabet can thus heighten the ambitions of protein engineers wishing to develop enzymes with new catalytic properties. PMID:28196894

  6. Experimental Study of Reciprocating Friction between Rape Stalk and Bionic Nonsmooth Surface Units

    PubMed Central

    Ma, Zheng; Li, Yaoming; Xu, Lizhang

    2015-01-01

    Background. China is the largest producer of rape oilseed in the world; however, the mechanization level of rape harvest is relatively low, because rape materials easily adhere to the cleaning screens of combine harvesters, resulting in significant cleaning losses. Previous studies have shown that bionic nonsmooth surface cleaning screens restrain the adhesion of rape materials, but the underlying mechanisms remain unclear. Objective. The reciprocating friction between rape stalk and bionic nonsmooth metal surface was examined. Methods. The short-time Fourier transform method was used to discriminate the stable phase of friction signals and the stick-lag distance was defined to analyze the stable reciprocating friction in a phase diagram. Results. The reciprocating friction between rape stalk and metal surface is a typical stick-slip friction, and the bionic nonsmooth metal surfaces with concave or convex units reduced friction force with increasing reciprocating frequency. The results also showed that the stick-lag distance of convex surface increased with reciprocating frequency, which indicated that convex surface reduces friction force more efficiently. Conclusions. We suggest that bionic nonsmooth surface cleaning screens, especially with convex units, restrain the adhesion of rape materials more efficiently compared to the smooth surface cleaning screens. PMID:27034611

  7. The purification, crystallization and preliminary diffraction of a glycerophosphodiesterase from Enterobacter aerogenes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, Colin J.; Carr, Paul D.; Kim, Hye-Kyung

    2006-07-01

    The metallo-glycerophosphodiesterase from E. aerogenes (GpdQ) has been cloned, expressed in E. coli and purified. Initial screening of crystallization conditions for this enzyme resulted in the identification of needles from one condition in a sodium malonate grid screen. Removal of the metals from the enzyme and subsequent optimization of these conditions led to crystals. The metallo-glycerophosphodiesterase from Enterobacter aerogenes (GpdQ) has been cloned, expressed in Escherichia coli and purified. Initial screening of crystallization conditions for this enzyme resulted in the identification of needles from one condition in a sodium malonate grid screen. Removal of the metals from the enzyme andmore » subsequent optimization of these conditions led to crystals that diffracted to 2.9 Å and belonged to space group P2{sub 1}3, with unit-cell parameter a = 164.1 Å. Self-rotation function analysis and V{sub M} calculations indicated that the asymmetric unit contains two copies of the monomeric enzyme, corresponding to a solvent content of 79%. It is intended to determine the structure of this protein utilizing SAD phasing from transition metals or molecular replacement.« less

  8. 33 CFR 110.232 - Southeast Alaska.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... explosives anchorage. (5) A wooden vessel must: (i) Be fitted with a radar reflector screen of metal of sufficient size to permit target indication on the radar screen of commercial type radar; or (ii) Have steel...

  9. 33 CFR 110.232 - Southeast Alaska.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... explosives anchorage. (5) A wooden vessel must: (i) Be fitted with a radar reflector screen of metal of sufficient size to permit target indication on the radar screen of commercial type radar; or (ii) Have steel...

  10. 33 CFR 110.232 - Southeast Alaska.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... explosives anchorage. (5) A wooden vessel must: (i) Be fitted with a radar reflector screen of metal of sufficient size to permit target indication on the radar screen of commercial type radar; or (ii) Have steel...

  11. 33 CFR 110.232 - Southeast Alaska.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... explosives anchorage. (5) A wooden vessel must: (i) Be fitted with a radar reflector screen of metal of sufficient size to permit target indication on the radar screen of commercial type radar; or (ii) Have steel...

  12. 33 CFR 110.232 - Southeast Alaska.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... explosives anchorage. (5) A wooden vessel must: (i) Be fitted with a radar reflector screen of metal of sufficient size to permit target indication on the radar screen of commercial type radar; or (ii) Have steel...

  13. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.

    PubMed

    van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P < .001) was a risk factor for adverse events during stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  14. Inborn errors of metabolism and expanded newborn screening: review and update.

    PubMed

    Mak, Chloe Miu; Lee, Han-Chih Hencher; Chan, Albert Yan-Wo; Lam, Ching-Wan

    2013-11-01

    Inborn errors of metabolism (IEM) are a phenotypically and genetically heterogeneous group of disorders caused by a defect in a metabolic pathway, leading to malfunctioning metabolism and/or the accumulation of toxic intermediate metabolites. To date, more than 1000 different IEM have been identified. While individually rare, the cumulative incidence has been shown to be upwards of 1 in 800. Clinical presentations are protean, complicating diagnostic pathways. IEM are present in all ethnic groups and across every age. Some IEM are amenable to treatment, with promising outcomes. However, high clinical suspicion alone is not sufficient to reduce morbidities and mortalities. In the last decade, due to the advent of tandem mass spectrometry, expanded newborn screening (NBS) has become a mandatory public health strategy in most developed and developing countries. The technology allows inexpensive simultaneous detection of more than 30 different metabolic disorders in one single blood spot specimen at a cost of about USD 10 per baby, with commendable analytical accuracy and precision. The sensitivity and specificity of this method can be up to 99% and 99.995%, respectively, for most amino acid disorders, organic acidemias, and fatty acid oxidation defects. Cost-effectiveness studies have confirmed that the savings achieved through the use of expanded NBS programs are significantly greater than the costs of implementation. The adverse effects of false positive results are negligible in view of the economic health benefits generated by expanded NBS and these could be minimized through increased education, better communication, and improved technologies. Local screening agencies should be given the autonomy to develop their screening programs in order to keep pace with international advancements. The development of biochemical genetics is closely linked with expanded NBS. With ongoing advancements in nanotechnology and molecular genomics, the field of biochemical genetics is still expanding rapidly. The potential of tandem mass spectrometry is extending to cover more disorders. Indeed, the use of genetic markers in T-cell receptor excision circles for severe combined immunodeficiency is one promising example. NBS represents the highest volume of genetic testing. It is more than a test and it warrants systematic healthcare service delivery across the pre-analytical, analytical, and post-analytical phases. There should be a comprehensive reporting system entailing genetic counselling as well as short-term and long-term follow-up. It is essential to integrate existing clinical IEM services with the expanded NBS program to enable close communication between the laboratory, clinicians, and allied health parties. In this review, we will discuss the history of IEM, its clinical presentations in children and adult patients, and its incidence among different ethnicities; the history and recent expansion of NBS, its cost-effectiveness, associated pros and cons, and the ethical issues that can arise; the analytical aspects of tandem mass spectrometry and post-analytical perspectives regarding result interpretation.

  15. EFFECTS OF LASER RADIATION ON MATTER. LASER PLASMA: Dynamics of a plasma formed by a surface optical-discharge in a metal vapour interacting with a cw CO2 laser beam

    NASA Astrophysics Data System (ADS)

    Zaikin, A. E.; Levin, A. V.; Petrov, A. L.

    1995-02-01

    A surface optical-discharge plasma was formed in a metal vapour under normal conditions by steady-state irradiation with a cw CO2 laser delivering radiation of moderate (2-4.5 MW cm-2) intensity. This plasma strongly screened the irradiated surface. Under the selected experimental conditions the optical discharge was not a continuous (steady-state) process. The plasma cloud was displaced along the beam out of the waist to a region where the laser radiation intensity was almost an order of magnitude less than the threshold for excitation of the optical-discharge plasma in the vapour. A strong screening of the metal surface, which could even completely stop evaporation of the metal, was observed. Self-oscillations of the optical-discharge plasma were observed for the first time in a vapour interacting with cw CO2 radiation: this was attributed to screening of the target surface. Within one period of the self-oscillations there were additional hf plasma pulsations which led to stratification of the plasma cloud. The results obtained were interpreted.

  16. Fuel cell with metal screen flow-field

    DOEpatents

    Wilson, M.S.; Zawodzinski, C.

    1998-08-25

    A polymer electrolyte membrane (PEM) fuel cell is provided with electrodes supplied with a reactant on each side of a catalyzed membrane assembly (CMA). The fuel cell includes a metal mesh defining a rectangular flow-field pattern having an inlet at a first corner and an outlet at a second corner located on a diagonal from the first corner, wherein all flow paths from the inlet to the outlet through the square flow field pattern are equivalent to uniformly distribute the reactant over the CMA. In a preferred form of metal mesh, a square weave screen forms the flow-field pattern. In a particular characterization of the present invention, a bipolar plate electrically connects adjacent fuel cells, where the bipolar plate includes a thin metal foil having an anode side and a cathode side; a first metal mesh on the anode side of the thin metal foil; and a second metal mesh on the cathode side of the thin metal foil. In another characterization of the present invention, a cooling plate assembly cools adjacent fuel cells, where the cooling plate assembly includes an anode electrode and a cathode electrode formed of thin conducting foils; and a metal mesh flow field there between for distributing cooling water flow over the electrodes to remove heat generated by the fuel cells. 11 figs.

  17. Fuel cell with metal screen flow-field

    DOEpatents

    Wilson, Mahlon S.; Zawodzinski, Christine

    2001-01-01

    A polymer electrolyte membrane (PEM) fuel cell is provided with electrodes supplied with a reactant on each side of a catalyzed membrane assembly (CMA). The fuel cell includes a metal mesh defining a rectangular flow-field pattern having an inlet at a first corner and an outlet at a second corner located on a diagonal from the first corner, wherein all flow paths from the inlet to the outlet through the square flow field pattern are equivalent to uniformly distribute the reactant over the CMA. In a preferred form of metal mesh, a square weave screen forms the flow-field pattern. In a particular characterization of the present invention, a bipolar plate electrically connects adjacent fuel cells, where the bipolar plate includes a thin metal foil having an anode side and a cathode side; a first metal mesh on the anode side of the thin metal foil; and a second metal mesh on the cathode side of the thin metal foil. In another characterization of the present invention, a cooling plate assembly cools adjacent fuel cells, where the cooling plate assembly includes an anode electrode and a cathode electrode formed of thin conducting foils; and a metal mesh flow field therebetween for distributing cooling water flow over the electrodes to remove heat generated by the fuel cells.

  18. Fuel cell with metal screen flow-field

    DOEpatents

    Wilson, Mahlon S.; Zawodzinski, Christine

    1998-01-01

    A polymer electrolyte membrane (PEM) fuel cell is provided with electrodes supplied with a reactant on each side of a catalyzed membrane assembly (CMA). The fuel cell includes a metal mesh defining a rectangular flow-field pattern having an inlet at a first corner and an outlet at a second corner located on a diagonal from the first corner, wherein all flow paths from the inlet to the outlet through the square flow field pattern are equivalent to uniformly distribute the reactant over the CMA. In a preferred form of metal mesh, a square weave screen forms the flow-field pattern. In a particular characterization of the present invention, a bipolar plate electrically connects adjacent fuel cells, where the bipolar plate includes a thin metal foil having an anode side and a cathode side; a first metal mesh on the anode side of the thin metal foil; and a second metal mesh on the cathode side of the thin metal foil. In another characterization of the present invention, a cooling plate assembly cools adjacent fuel cells, where the cooling plate assembly includes an anode electrode and a cathode electrode formed of thin conducting foils; and a metal mesh flow field therebetween for distributing cooling water flow over the electrodes to remove heat generated by the fuel cells.

  19. A comprehensive screen for volatile organic compounds in biological fluids.

    PubMed

    Sharp, M E

    2001-10-01

    A headspace gas chromatographic (GC) screen for common volatile organic compounds in biological fluids is reported. Common GC phases, DB-1 and DB-WAX, with split injection provide separation and identification of more than 40 compounds in a single 20-min run. In addition, this method easily accommodates quantitation. The screen detects commonly encountered volatile compounds at levels below 4 mg%. A control mixture, providing qualitative and semiquantitative information, is described. For comparison, elution of the volatiles on a specialty phase, DB-624, is reported. This method is an expansion and modification of a screen that had been used for more than 20 years. During its first year of use, the expanded screen has proven to be advantageous in routine forensic casework.

  20. Electrochemical power-producing cell. [Li/Se

    DOEpatents

    Cairns, E.J.; Chilenskas, A.A.; Steunenberg, R.K.; Shimotake, H.

    1972-05-30

    An electrochemical power-producing cell including a molten lithium metal anode, a molten selenium metal cathode, a paste electrolyte separating the anode from the cathode, an anode current collector, and a single layer of niobium expanded metal formed in corrugated shape as cathode current collector is described. In addition, means are provided for sealing the anode and the cathode from loss of lithium and selenium, respectively, and an insulator is provided between the anode housing and the paste electrolyte disk.

  1. Covered versus uncovered self-expandable metal stents for malignant biliary strictures: A meta-analysis and systematic review.

    PubMed

    Moole, Harsha; Bechtold, Matthew L; Cashman, Micheal; Volmar, Fritz H; Dhillon, Sonu; Forcione, David; Taneja, Deepak; Puli, Srinivas R

    2016-09-01

    Self-expandable metal stents (SEMS) are used for palliating inoperable malignant biliary strictures. It is unclear if covered metal stents are superior to uncovered metal stents in these patients. We compared clinical outcomes in patients with covered and uncovered stents. Studies using covered and uncovered metallic stents for palliation in patients with malignant biliary stricture were reviewed. Articles were searched in MEDLINE, PubMed, and Ovid journals. Fixed and random effects models were used to calculate the pooled proportions. Initial search identified 1436 reference articles, of which 132 were selected and reviewed. Thirteen studies (n = 2239) for covered and uncovered metallic stents which met the inclusion criteria were included in this analysis. Odds ratio for stent occlusion rates in covered vs. uncovered stents was 0.79 (95 % CI = 0.65 to 0.96). Survival benefit in patients with covered vs. uncovered stents showed the odds ratio to be 1.29 (95 % CI = 0.95 to 1.74). Pooled odds ratio for migration of covered vs. uncovered stents was 9.9 (95 % CI = 4.5 to 22.3). Covered stents seemed to have significantly lesser occlusion rates, increased odds of migration, and increased odds of pancreatitis compared to uncovered stents. There was no statistically significant difference in the survival benefit, overall adverse event rate, and patency period of covered vs. uncovered metal stents in patients with malignant biliary strictures.

  2. Influence of clamping plate permeability and metal screen structures on three-dimensional magnetic field and eddy current loss in end region of a turbo-generator by numerical analysis

    NASA Astrophysics Data System (ADS)

    Likun, Wang; Weili, Li; Yi, Xue; Chunwei, Guan

    2013-11-01

    A significant problem of turbogenerators on complex end structures is overheating of local parts caused by end losses in the end region. Therefore, it is important to investigate the 3-D magnetic field and eddy current loss in the end. In end region of operating large turbogenerator at thermal power plants, magnetic leakage field distribution is complex. In this paper, a 3-D mathematical model used for the calculation of the electromagnetic field in the end region of large turbo-generators is given. The influence of spatial locations of end structures, the actual shape and material of end windings, clamping plate, and copper screen are considered. Adopting the time-step finite element (FE) method and taking the nonlinear characteristics of the core into consideration, a 3-D transient magnetic field is calculated. The objective of this paper is to investigate the influence of clamping plate permeability and metal screen structures on 3-D electromagnetic field distribution and eddy current loss in end region of a turbo-generator. To reduce the temperature of copper screen, a hollow metal screen is proposed. The eddy current loss, which is gained from the 3D transient magnetic field, is used as heat source for the thermal field of end region. The calculated temperatures are compared with test data.

  3. Method of forming shrink-fit compression seal

    NASA Technical Reports Server (NTRS)

    Podgorski, T. J. (Inventor)

    1977-01-01

    A method for making a glass-to-metal seal is described. A domed metal enclosure having a machined seal ring is fitted to a glass post machined to a slight taper and to a desired surface finish. The metal part is then heated by induction in a vacuum. As the metal part heats and expands relative to the glass post, the metal seal ring, possessing a higher coefficient of expansion than the glass post, slides down the tapered post. Upon cooling, the seal ring crushes against the glass post forming the seal. The method results in a glass-to-metal seal possessing extremely good leak resistance, while the parts are kept clean and free of the contaminants.

  4. Manipulating the architecture of bimetallic nanostructures and their plasmonic properties

    NASA Astrophysics Data System (ADS)

    DeSantis, Christopher John

    There has been much interest in colloidal noble metal nanoparticles due to their fascinating plasmonic and catalytic properties. These properties make noble metal nanoparticles potentially useful for applications such as targeted drug delivery agents and hydrogen storage devices. Historically, shape-controlled noble metal nanoparticles have been predominantly monometallic. Recent synthetic advances provide access to bimetallic noble metal nanoparticles wherein their inherent multifunctionality and ability to fine tune or expand their surface chemistry and light scattering properties of metal nanoparticles make them popular candidates for many applications. Even so, there are currently few synthetic strategies to rationally design shape-controlled bimetallic nanocrystals; for this reason, few architectures are accessible. For example, the "seed-mediated method" is a popular means of achieving monodisperse shape-controlled bimetallic nanocrystals. In this process, small metal seeds are used as platforms for additional metal addition, allowing for conformal core shell nanostructures. However, this method has only been applied to single metal core/single metal shell structures; therefore, the surface compositions and architectures achievable are limited. This thesis expands upon the seed-mediated method by coupling it with co-reduction. In short, two metal precursors are simultaneously reduced to deposit metal onto pre-formed seeds in hopes that the interplay between two metal species facilitates bimetallic shell nanocrystals. Au/Pd was used as a test system due to favorable reduction potentials of metal precursors and good lattice match between Au and Pd. Alloyed shelled Au Au/Pd nanocrystals were achieved using this "seed-mediated co-reduction" approach. Symmetric eight-branched Au/Pd nanocrystals (octopods) are also prepared using this method. This thesis investigates many synthetic parameters that determine the shape outcome in Au/Pd nanocrystals during seed-mediated co-reduction. Plasmonic, catalytic, and assembly properties are also investigated in relation to nanocrystal shape and architecture. This work provides a foundation for the rational design of architecturally defined bimetallic nanostructures.

  5. Current Opinion in Biotechnology: Analytical Biotech

    PubMed Central

    Yannone, Steven M.; Hartung, Sophia; Menon, Angeli L.; Adams, Michael W. W.; Tainer, John A.

    2011-01-01

    The vital nature of metal uptake and balance in biology is evident in the highly evolved strategies to facilitate metal homeostasis in all three domains of life. Several decades of study on metals and metalloproteins have revealed numerous essential bio-metal functions. Recent advances in mass spectrometry, x-ray scattering/absorption, and proteomics have exposed a much broader usage of metals in biology than expected. Even elements such as uranium, arsenic, and lead are implicated in biological processes as part of an emerging and expansive view of bio-metals. Here we discuss opportunities and challenges for established and newer approaches to study metalloproteins with a focus on technologies that promise to rapidly expand our knowledge of metalloproteins and metal functions in biology. PMID:22138493

  6. Post-Hartree-Fock studies of the He/Mg(0001) interaction: Anti-corrugation, screening, and pairwise additivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lara-Castells, María Pilar de, E-mail: Pilar.deLara.Castells@csic.es; Fernández-Perea, Ricardo; Madzharova, Fani

    2016-06-28

    The adsorption of noble gases on metallic surfaces represents a paradigmatic case of van-der-Waals (vdW) interaction due to the role of screening effects on the corrugation of the interaction potential [J. L. F. Da Silva et al., Phys. Rev. Lett. 90, 066104 (2003)]. The extremely small adsorption energy of He atoms on the Mg(0001) surface (below 3 meV) and the delocalized nature and mobility of the surface electrons make the He/Mg(0001) system particularly challenging, even for state-of-the-art vdW-corrected density functional-based (vdW-DFT) approaches [M. P. de Lara-Castells et al., J. Chem. Phys. 143, 194701 (2015)]. In this work, we meet thismore » challenge by applying two different procedures. First, the dispersion-corrected second-order Möller-Plesset perturbation theory (MP2C) approach is adopted, using bare metal clusters of increasing size. Second, the method of increments [H. Stoll, J. Chem. Phys. 97, 8449 (1992)] is applied at coupled cluster singles and doubles and perturbative triples level, using embedded cluster models of the metal surface. Both approaches provide clear evidences of the anti-corrugation of the interaction potential: the He atom prefers on-top sites, instead of the expected hollow sites. This is interpreted as a signature of the screening of the He atom by the metal for the on-top configuration. The strong screening in the metal is clearly reflected in the relative contribution of successively deeper surface layers to the main dispersion contribution. Aimed to assist future dynamical simulations, a pairwise potential model for the He/surface interaction as a sum of effective He–Mg pair potentials is also presented, as an improvement of the approximation using isolated He–Mg pairs.« less

  7. Post-Hartree-Fock studies of the He/Mg(0001) interaction: Anti-corrugation, screening, and pairwise additivity

    NASA Astrophysics Data System (ADS)

    de Lara-Castells, María Pilar; Fernández-Perea, Ricardo; Madzharova, Fani; Voloshina, Elena

    2016-06-01

    The adsorption of noble gases on metallic surfaces represents a paradigmatic case of van-der-Waals (vdW) interaction due to the role of screening effects on the corrugation of the interaction potential [J. L. F. Da Silva et al., Phys. Rev. Lett. 90, 066104 (2003)]. The extremely small adsorption energy of He atoms on the Mg(0001) surface (below 3 meV) and the delocalized nature and mobility of the surface electrons make the He/Mg(0001) system particularly challenging, even for state-of-the-art vdW-corrected density functional-based (vdW-DFT) approaches [M. P. de Lara-Castells et al., J. Chem. Phys. 143, 194701 (2015)]. In this work, we meet this challenge by applying two different procedures. First, the dispersion-corrected second-order Möller-Plesset perturbation theory (MP2C) approach is adopted, using bare metal clusters of increasing size. Second, the method of increments [H. Stoll, J. Chem. Phys. 97, 8449 (1992)] is applied at coupled cluster singles and doubles and perturbative triples level, using embedded cluster models of the metal surface. Both approaches provide clear evidences of the anti-corrugation of the interaction potential: the He atom prefers on-top sites, instead of the expected hollow sites. This is interpreted as a signature of the screening of the He atom by the metal for the on-top configuration. The strong screening in the metal is clearly reflected in the relative contribution of successively deeper surface layers to the main dispersion contribution. Aimed to assist future dynamical simulations, a pairwise potential model for the He/surface interaction as a sum of effective He-Mg pair potentials is also presented, as an improvement of the approximation using isolated He-Mg pairs.

  8. Texaphyrins: Tumor Localizing Redox Active Expanded Porphyrins

    PubMed Central

    Arambula, Jonathan F.; Preihs, Christian; Borthwick, Derric; Magda, Darren; Sessler, Jonathan L.

    2011-01-01

    Texaphyrins, a class of tumor selective expanded porphyrins capable of coordinating large metals, have been found to act as redox mediators within biological systems. This review summarizes studies involving their experimentaluse in cancer chemotherapy. Mechanistic insights involving their presumed mode of action are also described, as well as certain structure activity relationships. Finally, newer texaphyrin-based applications associated with targeted drug delivery are presented. PMID:21355841

  9. Mechanical properties of different airway stents.

    PubMed

    Ratnovsky, Anat; Regev, Noa; Wald, Shaily; Kramer, Mordechai; Naftali, Sara

    2015-04-01

    Airway stents improve pulmonary function and quality of life in patients suffering from airway obstruction. The aim of this study was to compare main types of stents (silicone, balloon-dilated metal, self-expanding metal, and covered self-expanding metal) in terms of their mechanical properties and the radial forces they exert on the trachea. Mechanical measurements were carried out using a force gauge and specially designed adaptors fabricated in our lab. Numerical simulations were performed for eight different stent geometries, inserted into trachea models. The results show a clear correlation between stent diameter (oversizing) and the levels of stress it exerts on the trachea. Compared with uncovered metal stents, metal stents that are covered with less stiff material exert significantly less stress on the trachea while still maintaining strong contact with it. The use of such stents may reduce formation of mucosa necrosis and fistulas while still preventing stent migration. Silicone stents produce the lowest levels of stress, which may be due to weak contact between the stent and the trachea and can explain their propensity for migration. Unexpectedly, stents made of the same materials exerted different stresses due to differences in their structure. Stenosis significantly increases stress levels in all stents. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Evaluation of anti-migration properties of biliary covered self-expandable metal stents.

    PubMed

    Minaga, Kosuke; Kitano, Masayuki; Imai, Hajime; Harwani, Yogesh; Yamao, Kentaro; Kamata, Ken; Miyata, Takeshi; Omoto, Shunsuke; Kadosaka, Kumpei; Sakurai, Toshiharu; Nishida, Naoshi; Kudo, Masatoshi

    2016-08-14

    To assess anti-migration potential of six biliary covered self-expandable metal stents (C-SEMSs) by using a newly designed phantom model. In the phantom model, the stent was placed in differently sized holes in a silicone wall and retracted with a retraction robot. Resistance force to migration (RFM) was measured by a force gauge on the stent end. Radial force (RF) was measured with a RF measurement machine. Measured flare structure variables were the outer diameter, height, and taper angle of the flare (ODF, HF, and TAF, respectively). Correlations between RFM and RF or flare variables were analyzed using a linear correlated model. Out of the six stents, five stents were braided, the other was laser-cut. The RF and RFM of each stent were expressed as the average of five replicate measurements. For all six stents, RFM and RF decreased as the hole diameter increased. For all six stents, RFM and RF correlated strongly when the stent had not fully expanded. This correlation was not observed in the five braided stents excluding the laser cut stent. For all six stents, there was a strong correlation between RFM and TAF when the stent fully expanded. For the five braided stents, RFM after full stent expansion correlated strongly with all three stent flare structure variables (ODF, HF, and TAF). The laser-cut C-SEMS had higher RFMs than the braided C-SEMSs regardless of expansion state. RF was an important anti-migration property when the C-SEMS did not fully expand. Once fully expanded, stent flare structure variables plays an important role in anti-migration.

  11. Recycling Metals from Spent Screen-Printed Electrodes While Learning the Fundamentals of Electrochemical Sensing

    ERIC Educational Resources Information Center

    González-Sánchez, María-Isabel; Gómez-Monedero, Beatriz; Agrisuelas, Jerónimo; Valero, Edelmira

    2018-01-01

    A laboratory experiment in which students recycle silver and platinum selectively from spent screen-printed platinum electrodes is described. The recovered silver in solution is used to show its spontaneous redox reaction with a copper sheet. The recovered platinum is electrodeposited onto a screen-printed carbon electrode to develop a sensor for…

  12. Anesthesia and airway management for removing pulmonary self-expanding metallic stents.

    PubMed

    Doyle, D John; Abdelmalak, Basem; Machuzak, Michael; Gildea, Thomas R

    2009-11-01

    The use of bronchoscopically placed self-expanding metallic stents (SEMS) and silastic stents in patients suffering from tracheobronchial stenosis or similar problems has proven to be an important clinical option. When complications occur, it may be necessary to remove the device. Removal of a SEMS is usually performed during general anesthesia with muscle relaxation and positive pressure ventilation, often using total intravenous anesthesia. Airway management depends on stent type and location. Intubating patients' tracheas with a tracheal stent requires special caution, as it risks damaging tissue and dislodging the stent distally. Potential complications with removal include tracheal disruption, retained stent pieces, mucosal tears, re-obstruction requiring new stent placement, the need for postoperative ventilation, pneumothorax, damage to the pulmonary artery, and death.

  13. Clinical and psychological effects of excessive screen time on children.

    PubMed

    Domingues-Montanari, Sophie

    2017-04-01

    Over recent years, screen time has become a more complicated concept, with an ever-expanding variety of electronic media devices available throughout the world. Television remains the predominant type of screen-based activity among children. However, computer use, video games and ownership of devices, such as tablets and smart phones, are occurring from an increasingly young age. Screen time, in particular, television viewing, has been negatively associated with the development of physical and cognitive abilities, and positively associated with obesity, sleep problems, depression and anxiety. The physiological mechanisms that underlie the adverse health outcomes related to screen time and the relative contributions of different types of screen and media content to specific health outcomes are unclear. This review discusses the positive and negative effects of screen time on the physiological and psychological development of children. Furthermore, recommendations are offered to parents and clinicians. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  14. Advocacy, communication, and partnerships: Mobilizing for effective, widespread cervical cancer prevention.

    PubMed

    Wittet, Scott; Aylward, Jenny; Cowal, Sally; Drope, Jacqui; Franca, Etienne; Goltz, Sarah; Kuo, Taona; Larson, Heidi; Luciani, Silvana; Mugisha, Emmanuel; Schocken, Celina; Torode, Julie

    2017-07-01

    Both human papillomavirus (HPV) vaccination and screening/treatment are relatively simple and inexpensive to implement at all resource levels, and cervical cancer screening has been acknowledged as a "best buy" by the WHO. However, coverage with these interventions is low where they are needed most. Failure to launch or expand cervical cancer prevention programs is by and large due to the absence of dedicated funding, along with a lack of recognition of the urgent need to update policies that can hinder access to services. Clear and sustained communication, robust advocacy, and strategic partnerships are needed to inspire national governments and international bodies to action, including identifying and allocating sustainable program resources. There is significant momentum for expanding coverage of HPV vaccination and screening/preventive treatment in low-resource settings as evidenced by new global partnerships espousing this goal, and the participation of groups that previously had not focused on this critical health issue. © 2017 The Authors. International Journal of Gynecology & Obstetrics published by John Wiley & Sons Ltd on behalf of International Federation of Gynecology and Obstetrics.

  15. Orthogonal identification of gunshot residue with complementary detection principles of voltammetry, scanning electron microscopy, and energy-dispersive X-ray spectroscopy: sample, screen, and confirm.

    PubMed

    O'Mahony, Aoife M; Samek, Izabela A; Sattayasamitsathit, Sirilak; Wang, Joseph

    2014-08-19

    Field-deployable voltammetric screening coupled with complementary laboratory-based analysis to confirm the presence of gunshot residue (GSR) from the hands of a subject who has handled, loaded, or discharged a firearm is described. This protocol implements the orthogonal identification of the presence of GSR utilizing square-wave stripping voltammetry (SWSV) as a rapid screening tool along with scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) to confirm the presence of the characteristic morphology and metal composition of GSR particles. This is achieved through the judicious modification of the working electrode of a carbon screen-printed electrode (CSPE) with carbon tape (used in SEM analysis) to fix and retain a sample. A comparison between a subject who has handled and loaded a firearm and a subject who has had no contact with GSR shows the significant variations in voltammetric signals and the presence or absence of GSR-consistent particles and constituent metals. This initial electrochemical screening has no effect on the integrity of the metallic particles, and SEM/EDX analysis conducted prior to and postvoltammetry show no differences in analytical output. The carbon tape is instrumental in retaining the GSR sample after electrochemical analysis, supported by comparison with orthogonal detection at a bare CSPE. This protocol shows great promise as a two-tier detection system for the presence of GSR from the hands of a subject, whereby initial screening can be conducted rapidly onsite by minimally trained operators; confirmation can follow at the same substrate to substantiate the voltammetric results.

  16. Synthesis and characterization of ligational behavior of curcumin drug towards some transition metal ions: Chelation effect on their thermal stability and biological activity

    NASA Astrophysics Data System (ADS)

    Refat, Moamen S.

    2013-03-01

    Complexes of Cr(III), Mn(II), Fe(III), Co(II), Ni(II), Cu(II) and Zn(II) with curcumin ligand as antitumor activity were synthesized and characterized by elemental analysis, conductometry, magnetic susceptibility, UV-Vis, IR, Raman, ESR, 1H-NMR spectroscopy, X-ray diffraction analysis of powdered samples and thermal analysis, and screened for antimicrobial activity. The IR spectral data suggested that the ligand behaves as a monobasic bidentate ligand towards the central metal ion with an oxygen's donor atoms sequence of both sbnd OH and Cdbnd O groups under keto-enol structure. From the microanalytical data, the stoichiometry of the complexes 1:2 (metal:ligand) was found. The ligand and their metal complexes were screened for antibacterial activity against Escherichia Coli, Staphylococcus aureus, Bacillus subtilis and Pseudomonas aeruginosa and fungicidal activity against Aspergillus flavus and Candida albicans.

  17. Multiple light scattering in metallic ejecta produced under intense shockwave compression.

    PubMed

    Franzkowiak, J-E; Mercier, P; Prudhomme, G; Berthe, L

    2018-04-10

    A roughened metallic plate, subjected to intense shock wave compression, gives rise to an expanding ejecta particle cloud. Photonic Doppler velocimetry (PDV), a fiber-based heterodyne velocimeter, is often used to track ejecta velocities in dynamic compression experiments and on nanosecond time scales. Shortly after shock breakout at the metal-vacuum interface, a particular feature observed in many experiments in the velocity spectrograms is what appear to be slow-moving ejecta, below the free-surface velocity. Using Doppler Monte Carlo simulations incorporating the transport of polarization in the ejecta, we show that this feature is likely to be explained by the multiple scattering of light, rather than by possible collisions among particles, slowing down the ejecta. As the cloud expands in a vacuum, the contribution of multiple scattering decreases due to the limited field of view of the pigtailed collimator used to probe the ejecta, showing that the whole geometry of the system must be taken into account in the calculations to interpret and predict PDV measurements.

  18. Safeguarding the Health of the NASA Astronaut Community: the Need for Expanded Medical Monitoring for Former NASA Astronauts Under the Astronaut Occupational Health Program

    NASA Technical Reports Server (NTRS)

    Rossi, Meredith; Lee, Lesley; Wear, Mary; Van Baalen, Mary; Rhodes, Bradley

    2016-01-01

    The astronaut community is unique, and may be disproportionately exposed to occupational hazards not commonly seen in other communities. The extent to which the demands of the astronaut occupation and exposure to spaceflight-related hazards affect the health of the astronaut population over the life course is not completely known. Provision of health screening services to active and former astronauts ensures individual, mission, and community health and safety. Currently, the NASA Johnson Space Center (JSC) Flight Medicine Clinic (FMC) provides extensive medical monitoring to active astronauts throughout their careers. Upon retirement, astronauts may voluntarily return to the JSC FMC for an annual preventive exam. However, current retiree monitoring includes only selected screening tests, representing an opportunity for augmentation. The potential latent health effects of spaceflight demand an expanded framework of testing for former astronauts. The need is two-fold: screening tests widely recommended for other aging communities are necessary for astronauts to rule out conditions resulting from the natural aging process (e.g., colonoscopy, mammography), as opposed to conditions resulting directly from the astronaut occupation; and increased breadth of monitoring services will improve the understanding of occupational health risks and longitudinal health of the astronaut community, past, present, and future. To meet this need, NASA has begun an extensive exploration of the overall approach, cost, and policy implications of expanding existing medical monitoring under the Astronaut Occupational Health program for former NASA astronauts.

  19. ESHRE Task Force on Ethics and Law 21: genetic screening of gamete donors: ethical issues.

    PubMed

    Dondorp, W; De Wert, G; Pennings, G; Shenfield, F; Devroey, P; Tarlatzis, B; Barri, P; Diedrich, K; Eichenlaub-Ritter, U; Tüttelmann, F; Provoost, V

    2014-07-01

    This Task Force document explores the ethical issues involved in the debate about the scope of genetic screening of gamete donors. Calls for expanded donor screening arise against the background of both occasional findings of serious but rare genetic conditions in donors or donor offspring that were not detected through present screening procedures and the advent of new genomic technologies promising affordable testing of donors for a wide range of conditions. Ethical principles require that all stakeholders' interests are taken into account, including those of candidate donors. The message of the profession should be that avoiding all risks is impossible and that testing should remain proportional.

  20. 15 years of zebrafish chemical screening

    PubMed Central

    Rennekamp, Andrew J.; Peterson, Randall T.

    2015-01-01

    In 2000, the first chemical screen using living zebrafish in a multi-well plate was reported. Since then, more than 60 additional screens have been published describing whole-organism drug and pathway discovery projects in zebrafish. To investigate the scope of the work reported in the last 14 years and to identify trends in the field, we analyzed the discovery strategies of 64 primary research articles from the literature. We found that zebrafish screens have expanded beyond the use of developmental phenotypes to include behavioral, cardiac, metabolic, proliferative and regenerative endpoints. Additionally, many creative strategies have been used to uncover the mechanisms of action of new small molecules including chemical phenocopy, genetic phenocopy, mutant rescue, and spatial localization strategies. PMID:25461724

  1. Laminates and reinforced metals

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.

    1980-01-01

    A selective review is presented of the state of the art of metallic laminates and fiber reinforced metals called metallic matrix laminates (MMLs). Design and analysis procedures that are used for, and typical structural components that have been made from MMLs are emphasized. Selected MMLs, constituent materials, typical material properties and fabrication procedures are briefly described, including hybrids and superhybrids. Advantages, disadvantages, and special considerations required during design, analysis, and fabrication of MMLs are examined. Tabular and graphical data are included to illustrate key aspects of MMLs. Appropriate references are cited to provide a selective bibliography of a rapidly expanding and very promising research and development field.

  2. When VSEPR Fails: Experimental and Theoretical Investigations of the Behavior of Alkaline-Earth-Metal Acetylides

    PubMed Central

    Guino-o, Marites A.; Alexander, Jacob S.; McKee, Michael L.; Hope, Håkon; Englich, Ulrich B.

    2014-01-01

    The synthesis, structural, and spectral characterization as well as a theoretical study of a family of alkaline-earth-metal acetylides provides insights into synthetic access and the structural and bonding characteristics of this group of highly reactive compounds. Based on our earlier communication that reported unusual geometry for a family of triphenylsilyl-substituted alkaline-earth-metal acetylides, we herein present our studies on an expanded family of target derivatives, providing experimental and theoretical data to offer new insights into the intensively debated theme of structural chemistry in heavy alkaline-earth-metal chemistry. PMID:19844925

  3. High throughput screening using acoustic droplet ejection to combine protein crystals and chemical libraries on crystallization plates at high density

    DOE PAGES

    Teplitsky, Ella; Joshi, Karan; Ericson, Daniel L.; ...

    2015-07-01

    We describe a high throughput method for screening up to 1728 distinct chemicals with protein crystals on a single microplate. Acoustic droplet ejection (ADE) was used to co-position 2.5 nL of protein, precipitant, and chemicals on a MiTeGen in situ-1 crystallization plate™ for screening by co-crystallization or soaking. ADE-transferred droplets follow a precise trajectory which allows all components to be transferred through small apertures in the microplate lid. The apertures were large enough for 2.5 nL droplets to pass through them, but small enough so that they did not disrupt the internal environment created by the mother liquor. Using thismore » system, thermolysin and trypsin crystals were efficiently screened for binding to a heavy-metal mini-library. Fluorescence and X-ray diffraction were used to confirm that each chemical in the heavy-metal library was correctly paired with the intended protein crystal. Moreover, a fragment mini-library was screened to observe two known lysozyme We describe a high throughput method for screening up to 1728 distinct chemicals with protein crystals on a single microplate. Acoustic droplet ejection (ADE) was used to co-position 2.5 nL of protein, precipitant, and chemicals on a MiTeGen in situ-1 crystallization plate™ for screening by co-crystallization or soaking. ADE-transferred droplets follow a precise trajectory which allows all components to be transferred through small apertures in the microplate lid. The apertures were large enough for 2.5 nL droplets to pass through them, but small enough so that they did not disrupt the internal environment created by the mother liquor. Using this system, thermolysin and trypsin crystals were efficiently screened for binding to a heavy-metal mini-library. Fluorescence and X-ray diffraction were used to confirm that each chemical in the heavy-metal library was correctly paired with the intended protein crystal. A fragment mini-library was screened to observe two known lysozyme ligands using both co-crystallization and soaking. A similar approach was used to identify multiple, novel thaumatin binding sites for ascorbic acid. This technology pushes towards a faster, automated, and more flexible strategy for high throughput screening of chemical libraries (such as fragment libraries) using as little as 2.5 nL of each component.ds using both co-crystallization and soaking. We used a A similar approach to identify multiple, novel thaumatin binding sites for ascorbic acid. This technology pushes towards a faster, automated, and more flexible strategy for high throughput screening of chemical libraries (such as fragment libraries) using as little as 2.5 nL of each component.« less

  4. Testing and failure analysis to improve screening techniques for hermetically sealed metallized film capacitors for low energy applications

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Effective screening techniques are evaluated for detecting insulation resistance degradation and failure in hermetically sealed metallized film capacitors used in applications where low capacitor voltage and energy levels are common to the circuitry. A special test and monitoring system capable of rapidly scanning all test capacitors and recording faults and/or failures is examined. Tests include temperature cycling and storage as well as low, medium, and high voltage life tests. Polysulfone film capacitors are more heat stable and reliable than polycarbonate film units.

  5. Macrocycle peptides delineate locked-open inhibition mechanism for microorganism phosphoglycerate mutases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Hao; Dranchak, Patricia; Li, Zhiru

    Glycolytic interconversion of phosphoglycerate isomers is catalysed in numerous pathogenic microorganisms by a cofactor-independent mutase (iPGM) structurally distinct from the mammalian cofactor-dependent (dPGM) isozyme. The iPGM active site dynamically assembles through substrate-triggered movement of phosphatase and transferase domains creating a solvent inaccessible cavity. Here we identify alternate ligand binding regions using nematode iPGM to select and enrich lariat-like ligands from an mRNA-display macrocyclic peptide library containing >1012 members. Functional analysis of the ligands, named ipglycermides, demonstrates sub-nanomolar inhibition of iPGM with complete selectivity over dPGM. The crystal structure of an iPGM macrocyclic peptide complex illuminated an allosteric, locked-open inhibition mechanismmore » placing the cyclic peptide at the bi-domain interface. This binding mode aligns the pendant lariat cysteine thiolate for coordination with the iPGM transition metal ion cluster. The extended charged, hydrophilic binding surface interaction rationalizes the persistent challenges these enzymes have presented to small-molecule screening efforts highlighting the important roles of macrocyclic peptides in expanding chemical diversity for ligand discovery.« less

  6. Biodiscovery of aluminum binding peptides

    NASA Astrophysics Data System (ADS)

    Adams, Bryn L.; Sarkes, Deborah A.; Finch, Amethist S.; Hurley, Margaret M.; Stratis-Cullum, Dimitra

    2013-05-01

    Cell surface peptide display systems are large and diverse libraries of peptides (7-15 amino acids) which are presented by a display scaffold hosted by a phage (virus), bacteria, or yeast cell. This allows the selfsustaining peptide libraries to be rapidly screened for high affinity binders to a given target of interest, and those binders quickly identified. Peptide display systems have traditionally been utilized in conjunction with organic-based targets, such as protein toxins or carbon nanotubes. However, this technology has been expanded for use with inorganic targets, such as metals, for biofabrication, hybrid material assembly and corrosion prevention. While most current peptide display systems employ viruses to host the display scaffold, we have recently shown that a bacterial host, Escherichia coli, displaying peptides in the ubiquitous, membrane protein scaffold eCPX can also provide specific peptide binders to an organic target. We have, for the first time, extended the use of this bacterial peptide display system for the biodiscovery of aluminum binding 15mer peptides. We will present the process of biopanning with macroscopic inorganic targets, binder enrichment, and binder isolation and discovery.

  7. All kinds of reactivity: recent breakthroughs in metal-catalyzed alkyne chemistry.

    PubMed

    Anaya de Parrodi, Cecilia; Walsh, Patrick J

    2009-01-01

    Alkynes of reactions: Recent breakthroughs in metal-catalyzed alkyne reactions, which expand the synthetic utility of alkynes, have been achieved. These approaches broaden the range of alkynes that are accessible by C--N and C--C bond-forming reactions and demonstrate that the use of bifunctional heterobimetallic catalysts can lead to new reactivity and excellent enantioselectivity (see scheme).

  8. The inclusion of ADA-SCID in expanded newborn screening by tandem mass spectrometry.

    PubMed

    la Marca, Giancarlo; Giocaliere, Elisa; Malvagia, Sabrina; Funghini, Silvia; Ombrone, Daniela; Della Bona, Maria Luisa; Canessa, Clementina; Lippi, Francesca; Romano, Francesca; Guerrini, Renzo; Resti, Massimo; Azzari, Chiara

    2014-01-01

    Severe combined immunodeficiency due to adenosine-deaminase defect (ADA-SCID) is usually deadly in childhood because of severe recurrent infections. When clinical diagnosis is done, permanent damages due to infections or metabolite accumulation are often present. Gene therapy, bone marrow transplantation or enzyme replacement therapy may be effective if started early. The aim of this study was to set-up a robust method suitable for screening with a minimized preparation process and with inexpensive running costs, for diagnosing ADA-SCID by tandem mass spectrometry. ADA-SCID satisfies all the criteria for inclusion in a newborn screening program. We describe a protocol revised to incorporate adenosine and 2-deoxyadenosine testing into an expanded newborn screening program. We assessed the effectiveness of this approach testing dried blood spots from 4 genetically confirmed early-onset and 5 delayed-onset ADA-SCID patients. Reference values were established on 50,000 healthy newborns (deoxyadenosine <0.09μmol/L, adenosine <1.61μmol/L). We also developed a second tier test to distinguish true positives from false positives and improve the positive predictive value of an initial abnormal result. In the first 18 months, the pilot project has identified a newborn with a genetically confirmed defect in adenosine deaminase (ADA) gene. The results show that the method having great simplicity, low cost and low process preparations can be fully applicable to a mass screening program. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Zeolite A imidazolate frameworks

    NASA Astrophysics Data System (ADS)

    Hayashi, Hideki; Côté, Adrien P.; Furukawa, Hiroyasu; O'Keeffe, Michael; Yaghi, Omar M.

    2007-07-01

    Faujasite (FAU) and zeolite A (LTA) are technologically important porous zeolites (aluminosilicates) because of their extensive use in petroleum cracking and water softening. Introducing organic units and transition metals into the backbone of these types of zeolite allows us to expand their pore structures, enhance their functionality and access new applications. The invention of metal-organic frameworks and zeolitic imidazolate frameworks (ZIFs) has provided materials based on simple zeolite structures where only one type of cage is present. However, so far, no metal-organic analogues based on FAU or LTA topologies exist owing to the difficulty imposed by the presence of two types of large cage (super- and β-cages for FAU, α- and β-cages for LTA). Here, we have identified a strategy to produce an LTA imidazolate framework in which both the link geometry and link-link interactions play a decisive structure-directing role. We describe the synthesis and crystal structures of three porous ZIFs that are expanded analogues of zeolite A; their cage walls are functionalized, and their metal ions can be changed without changing the underlying LTA topology. Hydrogen, methane, carbon dioxide and argon gas adsorption isotherms are reported and the selectivity of this material for carbon dioxide over methane is demonstrated.

  10. Zeolite A imidazolate frameworks.

    PubMed

    Hayashi, Hideki; Côté, Adrien P; Furukawa, Hiroyasu; O'Keeffe, Michael; Yaghi, Omar M

    2007-07-01

    Faujasite (FAU) and zeolite A (LTA) are technologically important porous zeolites (aluminosilicates) because of their extensive use in petroleum cracking and water softening. Introducing organic units and transition metals into the backbone of these types of zeolite allows us to expand their pore structures, enhance their functionality and access new applications. The invention of metal-organic frameworks and zeolitic imidazolate frameworks (ZIFs) has provided materials based on simple zeolite structures where only one type of cage is present. However, so far, no metal-organic analogues based on FAU or LTA topologies exist owing to the difficulty imposed by the presence of two types of large cage (super- and beta-cages for FAU, alpha- and beta-cages for LTA). Here, we have identified a strategy to produce an LTA imidazolate framework in which both the link geometry and link-link interactions play a decisive structure-directing role. We describe the synthesis and crystal structures of three porous ZIFs that are expanded analogues of zeolite A; their cage walls are functionalized, and their metal ions can be changed without changing the underlying LTA topology. Hydrogen, methane, carbon dioxide and argon gas adsorption isotherms are reported and the selectivity of this material for carbon dioxide over methane is demonstrated.

  11. In situ detection of microbial c-type cytochrome based on intrinsic peroxidase-like activity using screen-printed carbon electrode.

    PubMed

    Wen, Junlin; He, Daigui; Yu, Zhen; Zhou, Shungui

    2018-08-15

    C-type cytochromes (c-cyts) facilitate microbial extracellular electron transfer and play critical roles in biogeochemical cycling, bioelectricity generation and bioremediation. In this study, a simple and effective method has been developed to detect microbial c-cyts by means of peroxidase mimetic reaction on screen-printed carbon electrode (SPCE). To this end, bacteria cells were immobilized onto the working electrode surface of SPCE by a simple drop casting. After introducing 3,3',5,5'-tetramethylbenzidine (TMB) solution, microbial c-cyts with peroxidase-like activity catalyze the oxidation of TMB in the presence of hydrogen peroxide. The oxidized TMB was electrochemically determined and the current signal was employed to calculate the c-cyts content. This electrochemical method is highly sensitive for microbial c-cyts with a low detection limit of 40.78 fmol and a wide detection range between 51.70 fmol and 6.64 pmol. Moreover, the proposed technique can be universally expanded to detect c-cyts in other bacteria species such as Fontibacter ferrireducens, Pseudomonas aeruginosa, Comamonas guangdongensis and Escherichia coli. Furthermore, the proposed method confers an in situ facile and quantitative c-cyts detection without any destructive sample preparations, complex electrode modifications and expensive enzyme- or metal particle- based signal amplification. The suggested method advances an intelligent strategy for in situ quantification of microbial c-cyts and consequently holds promising application potential in microbiology and environmental science. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Theoretical and experimental research on laser-beam homogenization based on metal gauze

    NASA Astrophysics Data System (ADS)

    Liu, Libao; Zhang, Shanshan; Wang, Ling; Zhang, Yanchao; Tian, Zhaoshuo

    2018-03-01

    Method of homogenization of CO2 laser heating by means of metal gauze is researched theoretically and experimentally. Distribution of light-field of expanded beam passing through metal gauze was numerically calculated with diffractive optical theory and the conclusion is that method is effective, with comparing the results to the situation without metal gauze. Experimentally, using the 30W DC discharge laser as source and enlarging beam by concave lens, with and without metal gauze, beam intensity distributions in thermal paper were compared, meanwhile the experiments based on thermal imager were performed. The experimental result was compatible with theoretical calculation, and all these show that the homogeneity of CO2 laser heating could be enhanced by metal gauze.

  13. Detail of 25' highband reflector screen poles with monopole antenna ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of 25' high-band reflector screen poles with monopole antenna elements behind, note the metal sleeve bases of the reflector screen poles and the guy wire anchors from the dipole antenna elements (left foreground), view facing north northwest - U.S. Naval Base, Pearl Harbor, Naval Radio Station, AF/FRD-10 Circularly Disposed Antenna Array, Wahiawa, Honolulu County, HI

  14. State of the metal core in nanosecond exploding wires and related phenomena

    NASA Astrophysics Data System (ADS)

    Sarkisov, G. S.; Sasorov, P. V.; Struve, K. W.; McDaniel, D. H.

    2004-08-01

    Experiments show that an expanding metal wire core that results from a nanosecond electrical explosion in vacuum consists primarily of three different states: solid, microdrop, and gas-plasma. The state of the wire core depends both on the amount of energy deposited before the voltage breakdown and on the heating conditions. For small amounts of deposited energy (on the order of solid-stage enthalpy), the wire core remains in a solid state or is partially disintegrated. For a high level of deposited energy (more than vaporization energy) the wire core is in a gas-plasma state. For an intermediate level of deposited energy (more than melting but less than vaporization), the wire disintegrates into hot liquid microdrops or clusters of submicron size. For a wire core in the cluster state, interferometry demonstrates weak (or even absent) phaseshift. Light emission shows a "firework effect"—the long late-time radiation related to the emission by the expanding cylinder of hot microparticles. For the wire core in a gas-plasma state, interferometry demonstrates a large phaseshift and a fast reduction in light emission due to adiabatic cooling of the expanding wire core. The simulation of this firework effect agrees well with experimental data, assuming submicron size and a temperature approaching boiling for the expanded microparticles cylinder.

  15. Thin-Film Thermoelectric Module for Power Generator Applications Using a Screen-Printing Method

    NASA Astrophysics Data System (ADS)

    Lee, Heon-Bok; Yang, Hyun Jeong; We, Ju Hyung; Kim, Kukjoo; Choi, Kyung Cheol; Cho, Byung Jin

    2011-05-01

    A new process for fabricating a low-cost thermoelectric module using a screen-printing method has been developed. Thermoelectric properties of screen-printed ZnSb films were investigated in an effort to develop a thermoelectric module with low cost per watt. The screen-printed Zn x Sb1- x films showed a low carrier concentration and high Seebeck coefficient when x was in the range of 0.5 to 0.57 and the annealing temperature was kept below 550°C. When the annealing temperature was higher than 550°C, the carrier concentration of the Zn x Sb1- x films reached that of a metal, leading to a decrease of the Seebeck coefficient. In the present experiment, the optimized carrier concentration of screen-printed ZnSb was 7 × 1018/cm3. The output voltage and power density of the ZnSb film were 10 mV and 0.17 mW/cm2, respectively, at Δ T = 50 K. A thermoelectric module was produced using the proposed screen-printing approach with ZnSb and CoSb3 as p-type and n-type thermoelectric materials, respectively, and copper as the pad metal.

  16. New Area Law in General Relativity.

    PubMed

    Bousso, Raphael; Engelhardt, Netta

    2015-08-21

    We report a new area law in general relativity. A future holographic screen is a hypersurface foliated by marginally trapped surfaces. We show that their area increases monotonically along the foliation. Future holographic screens can easily be found in collapsing stars and near a big crunch. Past holographic screens exist in any expanding universe and obey a similar theorem, yielding the first rigorous area law in big bang cosmology. Unlike event horizons, these objects can be identified at finite time and without reference to an asymptotic boundary. The Bousso bound is not used, but it naturally suggests a thermodynamic interpretation of our result.

  17. [Membrane-covered self-expanding stents in the treatment of high-positioned esophageal stenosis or fistula].

    PubMed

    Liu, Jing-zheng; Zhong, Yun-shi; Xu, Mei-dong; Chen, Wei-feng; Zhou, Ping-hong; Yao, Li-qing

    2013-12-01

    To investigate the efficacy and safety of membrane-covered self-expanding metal stent in the treatment of high-positioned esophageal diseases, including esophageal stenosis, esophagotracheal fistula and anastomotic stricture. Clinical data of 84 patients who underwent stenting in our center from May 2005 to July 2013 were retrospectively analyzed. Of 84 patients, 31 were diagnosed as esophageal malignant stenosis, 2 compression stenosis, 10 radiation stenosis, 4 recurrent malignant stenosis, 27 anastomotic stricture, 1 esophageal stenosis after endoscopic submucosal dissection (ESD), 7 esophageal-tracheal fistula, 1 esophageal-mediastinal fistula, and 1 remnant stomach fistula. Distance from stenosis or fistula to central incisor was 15-20 cm in 48 cases, and more than 20 cm in 36 cases. All the patients were treated by 16 mm membrane-covered self-expanding metal stents. Main clinical manifestations and complications were evaluated. A total of 100 stents were placed in 84 patients,with a success rate of 100%. There were no complications such as perforation and bleeding during operation. Dysphagia and cough were improved quickly with a success rate of 100%. After the placement of stents, the incidence of complication was 6.0% (5/84), of which 2 cases were severe retrosternal pain, 1 was tracheal collapse, and 2 were stent displacement. Seventy-six patients (90.5%) received complete follow-up of 1 to 36 months (mean 15 months). Re-stenosis occurred in 4 cases, new esophageal-tracheal fistula in 2 cases. Among these 6 cases, 5 cases underwent successfully stent placement once again, and another one case received Savary bougie and Argon-ion coagulation with good efficacy. Endoscopic membrane-covered self-expanding metal stent placement is effective and safe for the relieve of dysphagia symptoms and the sealing of esophagotracheal fistula.

  18. [The application of Y-shaped self-expandable covered metal stents in the thoracostomach-airway fistula: a single center, 11 years experience].

    PubMed

    Fang, Yi; Li, Tengfei; Han, Xinwei; Wu, Gang; Ren, Jianzhuang; Ren, Kewei; Lu, Huibin; Zhang, Quanhui; Li, Zongming

    2015-08-01

    To investigate the clinical feasibility and efficacy of Y-shaped self-expandable covered metal stents (Y-stents) in the management of thoracostomach-airway fistula. Retrospective analysis was performed for 108 patients treated for thoracostomach-airway fistula with Y-shaped self-expandable coated metal stents between April 2003 and October 2014. Y-stents were designed based on the dimensions of trachea and bronchus and sites of the fistula and then were inserted under DSA monitoring. There were 65 cases with single big Y-stent placement, 26 cases with single small Y-stent placement, 23 cases with double Y-stents placement, and 1 case with 3 Y-stents placement. Stent implantation was successfully accomplished with single manipulation in all patients. Complete occlusion of the fistula was obtained in 104 patients after the primary manipulation, and 4 patients required a secondary manipulation where a double Y-stents was inserted because of failure of primary manipulate. Ninety-two patients completed the follow-up , while 16 were lost. Fifty-nine patients died while 33 were alive with marked improvement in their quality of life. The placement of Y-stents can effectively occlude the thoracostomach-airway fistula in patients who had had the esophageal tumors resected. The technique is not only feasible but reliable to improve the quality of life of the patients.

  19. Modems and More: The Computer Branches Out.

    ERIC Educational Resources Information Center

    Dyrli, Odvard Egil

    1986-01-01

    Surveys new "peripherals," electronic devices that attach to computers. Devices such as videodisc players, desktop laser printers, large screen projectors, and input mechanisms that circumvent the keyboard dramatically expand the computer's instructional uses. (Author/LHW)

  20. The performance of spatially offset Raman spectroscopy for liquid explosive detection

    NASA Astrophysics Data System (ADS)

    Loeffen, Paul W.; Maskall, Guy; Bonthron, Stuart; Bloomfield, Matthew; Tombling, Craig; Matousek, Pavel

    2016-10-01

    Aviation security requirements adopted in 2014 require liquids to be screened at most airports throughout Europe, North America and Australia. Cobalt's unique Spatially Offset Raman Spectroscopy (SORS™) technology has proven extremely effective at screening liquids, aerosols and gels (LAGS) with extremely low false alarm rates. SORS is compatible with a wide range of containers, including coloured, opaque or clear plastics, glass and paper, as well as duty-free bottles in STEBs (secure tamper-evident bags). Our award-winning Insight range has been specially developed for table-top screening at security checkpoints. Insight systems use our patented SORS technology for rapid and accurate chemical analysis of substances in unopened non-metallic containers. Insight100M™ and the latest member of the range - Insight200M™ - also screen metallic containers. Our unique systems screen liquids, aerosols and gels with the highest detection capability and lowest false alarm rates of any ECAC-approved scanner, with several hundred units already in use at airports including eight of the top ten European hubs. This paper presents an analysis of real performance data for these systems.

  1. Computational Design of Metal Ion Sequestering Agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hay, Benjamin P.; Rapko, Brian M.

    Organic ligands that exhibit a high degree of metal ion recognition are essential precursors for developing separation processes and sensors for metal ions. Since the beginning of the nuclear era, much research has focused on discovering ligands that target specific radionuclides. Members of the Group 1A and 2A cations (e.g., Cs, Sr, Ra) and the f-block metals (actinides and lanthanides) are of primary concern to DOE. Although there has been some success in identifying ligand architectures that exhibit a degree of metal ion recognition, the ability to control binding affinity and selectivity remains a significant challenge. The traditional approach formore » discovering such ligands has involved lengthy programs of organic synthesis and testing that, in the absence of reliable methods for screening compounds before synthesis, have resulted in much wasted research effort. This project seeks to enhance and strengthen the traditional approach through computer-aided design of new and improved host molecules. Accurate electronic structure calculations are coupled with experimental data to provide fundamental information about ligand structure and the nature of metal-donor group interactions (design criteria). This fundamental information then is used in a molecular mechanics model (MM) that helps us rapidly screen proposed ligand architectures and select the best members from a set of potential candidates. By using combinatorial methods, molecule building software has been developed that generates large numbers of candidate architectures for a given set of donor groups. The specific goals of this project are: • further understand the structural and energetic aspects of individual donor group- metal ion interactions and incorporate this information within the MM framework • further develop and evaluate approaches for correlating ligand structure with reactivity toward metal ions, in other words, screening capability • use molecule structure building software to generate large numbers of candidate ligand architectures for given sets of donor groups • screen candidates and identify ligand architectures that will exhibit enhanced metal ion recognition. These new capabilities are being applied to ligand systems identified under other DOEsponsored projects where studies have suggested that modifying existing architectures will lead to dramatic enhancements in metal ion binding affinity and selectivity. With this in mind, we are collaborating with Professors R. T. Paine (University of New Mexico), K. N. Raymond (University of California, Berkeley), and J. E. Hutchison (University of Oregon), and Dr. B. A. Moyer (Oak Ridge National Laboratory) to obtain experimental validation of the predicted new ligand structures. Successful completion of this study will yield molecular-level insight into the role that ligand architecture plays in controlling metal ion complexation and will provide a computational approach to ligand design.« less

  2. The Importance of Transition Metals in the Expanding Network of Microbial Metabolism in the Archean Eon

    NASA Astrophysics Data System (ADS)

    Moore, E. K.; Jelen, B. I.; Giovannelli, D.; Prabhu, A.; Raanan, H.; Falkowski, P. G.

    2017-12-01

    Deep time changes in Earth surface redox conditions, particularly due to global oxygenation, has impacted the availability of different metals and substrates that are central in biology. Oxidoreductase proteins are molecular nanomachines responsible for all biological electron transfer processes across the tree of life. These enzymes largely contain transition metals in their active sites. Microbial metabolic pathways form a global network of electron transfer, which expanded throughout the Archean eon. Older metabolisms (sulfur reduction, methanogenesis, anoxygenic photosynthesis) accessed negative redox potentials, while later evolving metabolisms (oxygenic photosynthesis, nitrification/denitrification, aerobic respiration) accessed positive redox potentials. The incorporation of different transition metals facilitated biological innovation and the expansion of the network of microbial metabolism. Network analysis was used to examine the connections between microbial taxa, metabolic pathways, crucial metallocofactors, and substrates in deep time by incorporating biosignatures preserved in the geologic record. Nitrogen fixation and aerobic respiration have the highest level of betweenness among metabolisms in the network, indicating that the oldest metabolisms are not the most central. Fe has by far the highest betweenness among metals. Clustering analysis largely separates High Metal Bacteria (HMB), Low Metal Bacteria (LMB), and Archaea showing that simple un-weighted links between taxa, metabolism, and metals have phylogenetic relevance. On average HMB have the highest betweenness among taxa, followed by Archaea and LMB. There is a correlation between the number of metallocofactors and metabolic pathways in representative bacterial taxa, but Archaea do not follow this trend. In many cases older and more recently evolved metabolisms were clustered together supporting previous findings that proliferation of metabolic pathways is not necessarily chronological.

  3. Expandable stents.

    PubMed

    Nesbitt, J C; Carrasco, H

    1996-05-01

    Expandable metallic stents are effective in selected patients with malignant or benign airway stenoses. When used for malignant lesions, the primary purpose of the stent is to improve the quality of life; stents are usually chosen for palliation of symptoms in recognition of the low likelihood of success for other therapy. For patients with benign stenoses, the stents provide a permanent source of structural support to alleviate the narrowed segment. The advantages of the expandable metallic stents are as follows: (1) they can be inserted through an endotracheal tube or under local anesthesia with relative simplicity under fluoroscopic guidance; (2) they do not impair the drainage of sputum because ciliary movement is not interrupted; (3) over a period of a few weeks, the meshwork is gradually covered with mucosa as the stent becomes incorporated into the airway wall; (4) ventilation usually is not impaired if the metallic mesh stent covers another nonstenosed bronchus, because the interstices of the stent are nonobstructive; and (5) they are dynamic and continue to expand over time, particularly if concurrent treatment achieves an effect on the lesion that caused stenosis. Disadvantages of the expandable stent include (1) they often are only temporarily effective for tracheobronchial stenosis due to intraluminal tumor or granulation tissue, both of which can grow between the wires; (2) they are considered permanent stents because removal is difficult; and (3) they can be poorly positioned during placement or can become displaced by progressive migration after placement, and they cannot be repositioned. A relative contraindication to insertion is an inflammatory process or infection that can predispose to granulation formation, particularly at the points of maximal contact pressure of the stent to the airway mucosa. In the presence of inflammation, it may be better to use a silicone prosthesis until the inflammatory process subsides and fibrosis occurs. Granulation tissue is less likely to occur in areas of established scar than in areas of acute inflammation. In circumstances in which it is essential that a stent remain only temporarily, an expandable stent should not be inserted in favor of a silicone stent, which can be removed. In the future, expandable stents may have silicone coverings or may be constructed of materials that facilitate removal. Until that time, expandable stents should be considered permanent and nonremovable. Subtle differences exist among the available stents. Standard is low-profile expandable construction from wire mesh. A relatively minor difference is the slightly wider expansibility of the Gianturco stent, a quality that makes it the best suited of the three stents for lesions that involve tracheomalacia. Perhaps the only major difference between the Wallstent and the Gianturco and Palmaz stents is its better ability to conform to tortuous lesions. In an acutely angled stricture, a Wallstent offers a better opportunity for successful placement than other stents. The filamentous meshwork of the Wallstent allows it to bend and conform better to distorted airways. The Gianturco and Palmaz stents have little longitudinal elasticity, which makes them less effective in a tortuous or highly angulated airway stenosis. Expandable stents have demonstrated their efficacy and exposed their limitations in the treatment of airway stenoses. Refinements in design should help to lessen specific disadvantages and problems. Covered expandable stents, a realistic prospect, have specific advantages over standard expandable stents; they will be removable and prevent tumor ingrowth. Current investigative work with such prostheses for the vascular system may provide the foundation for their investigative use in the airway. In essence, two categories of expandable stents are evolving, covered and uncovered, each having unique features adaptable to the specific clinical needs.

  4. Materials science: Clockwork at the atomic scale

    NASA Astrophysics Data System (ADS)

    Ležaić, Marjana

    2016-05-01

    Design rules for exotic materials known as polar metals have been put into practice in thin films. The findings will motivate studies of how a phenomenon called screening can be manipulated to generate new phases in metals. See Letter p.68

  5. Breast cancer screening services: trade-offs in quality, capacity, outreach, and centralization.

    PubMed

    Güneş, Evrim D; Chick, Stephen E; Akşin, O Zeynep

    2004-11-01

    This work combines and extends previous work on breast cancer screening models by explicitly incorporating, for the first time, aspects of the dynamics of health care states, program outreach, and the screening volume-quality relationship in a service system model to examine the effect of public health policy and service capacity decisions on public health outcomes. We consider the impact of increasing standards for minimum reading volume to improve quality, expanding outreach with or without decentralization of service facilities, and the potential of queueing due to stochastic effects and limited capacity. The results indicate a strong relation between screening quality and the cost of screening and treatment, and emphasize the importance of accounting for service dynamics when assessing the performance of health care interventions. For breast cancer screening, increasing outreach without improving quality and maintaining capacity results in less benefit than predicted by standard models.

  6. U.S. military enlisted accession mental health screening: history and current practice.

    PubMed

    Cardona, Robert Andrew; Ritchie, Elspeth Cameron

    2007-01-01

    Through the stimulus of war and concerns about neuropsychiatric disability, the U.S. military developed methods to rapidly screen the mental health of World War I and II draftees. Intelligence testing and brief psychiatric screening expanded the accession physical examination and underwent revision to identify only gross mental health disability. Supplemental psychiatric evaluations and written psychological screening tools were abandoned after postwar assessments; they demonstrated poor predictive power in evaluating recruit service capacity for combat environments. Currently, only three mental health accession tools are used to screen applicants before their entrance into military service, namely, educational achievement, cognitive testing, and a cursory psychiatric evaluation. The Navy and Air Force use a fourth screening measure during entry-level training. Educational attainment with high school graduation has been the strongest predictor of finishing a service term. The purpose of this article is to provide both a historical review and a review of testing efforts.

  7. Newborn screening progress in developing countries--overcoming internal barriers.

    PubMed

    Padilla, Carmencita D; Krotoski, Danuta; Therrell, Bradford L

    2010-04-01

    Newborn screening is an important public health measure aimed at early identification and management of affected newborns thereby lowering infant morbidity and mortality. It is a comprehensive system of education, screening, follow-up, diagnosis, treatment/management, and evaluation that must be institutionalized and sustained within public health systems often challenged by economic, political, and cultural considerations. As a result, developing countries face unique challenges in implementing and expanding newborn screening that can be grouped into the following categories: (1) planning, (2) leadership, (3) medical support, (4) technical support, (5) logistical support, (6) education, (7) protocol and policy development, (8) administration, (9) evaluation, and (10) sustainability. We review some of the experiences in overcoming implementation challenges in developing newborn screening programs, and discuss recent efforts to encourage increased newborn screening through support networking and information exchange activities in 2 regions-the Asia Pacific and the Middle East/North Africa. Copyright 2010 Elsevier Inc. All rights reserved.

  8. Novel biliary self-expanding metal stents: indications and applications.

    PubMed

    Blero, Daniel; Huberty, Vincent; Devière, Jacques

    2015-03-01

    Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.

  9. Use of a Palmaz stent for tracheomalacia: case report of an infant with esophageal atresia.

    PubMed

    Tazuke, Y; Kawahara, H; Yagi, M; Yoneda, A; Soh, H; Maeda, K; Yamamoto, T; Imura, K

    1999-08-01

    A male infant with congenital cardiac anomalies and esophageal atresia with tracheoesophageal fistula (EA-TEF) showed intractable respiratory symptoms after delayed primary repair of EA-TEF. Computed tomography demonstrated that the trachea was compressed by the enlarged aorta. Artificial ventilation was necessary even after aortopexy performed at 2 months of age. At 140 days of age, an expandable metallic stent (Palmaz stent) was inserted through a rigid bronchoscope into the trachea underfluoroscopic control. His respiratory status improved dramatically, and he was extubated in 18 hours. Although the follow-up period has been 9 months, the short-term result is satisfactory. The expandable metallic stent placement should be considered in patients with EA-TEF who show intractable respiratory symptoms caused by tracheomalacia.

  10. Should Israel screen all mothers-to-be to prevent early-onset of neonatal group B streptococcal disease? A cost-utility analysis.

    PubMed

    Ginsberg, Gary M; Eidelman, Arthur I; Shinwell, Eric; Anis, Emilia; Peyser, Reuven; Lotan, Yoram

    2013-02-20

    In Israel, an average of 37 children are born each year with sepsis and another four with meningitis as a result of Group B Streptococcal (GBS) disease. Israel currently only screens mothers with defined risk factors (around 15% of all pregnancies) in order to identify candidates for Intrapartum Antiobiotic Prophyhlaxis (IAP) of GBS. This paper presents a cost-utility analysis of implementing an alternative strategy, which would expand the current protocol to one aiming to screen all pregnant women at 35-37 weeks gestation based on taking a vaginal culture for GBS. A spreadsheet model was built incorporating technical, epidemiological, health service costs, demographic and economic data based primarily on Israeli sources. The intervention of universal screening (compared with the current scenario) would increase screening costs from 580,000 NIS to 3,278,000 million NIS. In addition, the intervention would also increase penicillin costs from 39,000 NIS to 221,000 NIS. Current culture screening of approximately 15% of mothers-to-be with high risk factors resulted in 42 GBS births in 2008-9 (0.253/1000 births). Expanding culture screening to 85% of mothers-to-be, will decrease the number of GBS births to 17.3 (0.104/1000 births). The initial 2.9 million NIS incremental intervention costs are offset by decreased treatment costs of 1.9 million NIS and work productivity gains of 811,000 NIS as a result of a decrease in neurological sequelae from GBS caused meningitis. Thus the resultant net cost of the intervention is only around 134,000 NIS. Culture based screening will reduce the burden of disease by 12.6 discounted Quality Adjusted Life Years (QALYS), giving a very cost effective baseline incremental cost per QALY (cf. risk factor screening) of 10,641 NIS per QALY. The data was very sensitive to rates of anaphylactic shock and changes in the percentage of meningitis cases that had associated long term-sequelae. It is recommended that Israel adopt universal culture-based GBS screening.

  11. Evaluation of anti-migration properties of biliary covered self-expandable metal stents

    PubMed Central

    Minaga, Kosuke; Kitano, Masayuki; Imai, Hajime; Harwani, Yogesh; Yamao, Kentaro; Kamata, Ken; Miyata, Takeshi; Omoto, Shunsuke; Kadosaka, Kumpei; Sakurai, Toshiharu; Nishida, Naoshi; Kudo, Masatoshi

    2016-01-01

    AIM: To assess anti-migration potential of six biliary covered self-expandable metal stents (C-SEMSs) by using a newly designed phantom model. METHODS: In the phantom model, the stent was placed in differently sized holes in a silicone wall and retracted with a retraction robot. Resistance force to migration (RFM) was measured by a force gauge on the stent end. Radial force (RF) was measured with a RF measurement machine. Measured flare structure variables were the outer diameter, height, and taper angle of the flare (ODF, HF, and TAF, respectively). Correlations between RFM and RF or flare variables were analyzed using a linear correlated model. RESULTS: Out of the six stents, five stents were braided, the other was laser-cut. The RF and RFM of each stent were expressed as the average of five replicate measurements. For all six stents, RFM and RF decreased as the hole diameter increased. For all six stents, RFM and RF correlated strongly when the stent had not fully expanded. This correlation was not observed in the five braided stents excluding the laser cut stent. For all six stents, there was a strong correlation between RFM and TAF when the stent fully expanded. For the five braided stents, RFM after full stent expansion correlated strongly with all three stent flare structure variables (ODF, HF, and TAF). The laser-cut C-SEMS had higher RFMs than the braided C-SEMSs regardless of expansion state. CONCLUSION: RF was an important anti-migration property when the C-SEMS did not fully expand. Once fully expanded, stent flare structure variables plays an important role in anti-migration. PMID:27570427

  12. Highly Expandable Human iPS Cell-Derived Neural Progenitor Cells (NPC) and Neurons for Central Nervous System Disease Modeling and High-Throughput Screening.

    PubMed

    Cheng, Chialin; Fass, Daniel M; Folz-Donahue, Kat; MacDonald, Marcy E; Haggarty, Stephen J

    2017-01-11

    Reprogramming of human somatic cells into induced pluripotent stem (iPS) cells has greatly expanded the set of research tools available to investigate the molecular and cellular mechanisms underlying central nervous system (CNS) disorders. Realizing the promise of iPS cell technology for the identification of novel therapeutic targets and for high-throughput drug screening requires implementation of methods for the large-scale production of defined CNS cell types. Here we describe a protocol for generating stable, highly expandable, iPS cell-derived CNS neural progenitor cells (NPC) using multi-dimensional fluorescence activated cell sorting (FACS) to purify NPC defined by cell surface markers. In addition, we describe a rapid, efficient, and reproducible method for generating excitatory cortical-like neurons from these NPC through inducible expression of the pro-neural transcription factor Neurogenin 2 (iNgn2-NPC). Finally, we describe methodology for the use of iNgn2-NPC for probing human neuroplasticity and mechanisms underlying CNS disorders using high-content, single-cell-level automated microscopy assays. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  13. Effectiveness of common fish screen materials for protecting lamprey ammocoetes—Influence of sweeping velocities and decreasing flows

    USGS Publications Warehouse

    Mesa, Matthew G.; Liedtke, Theresa L.; Weiland, Lisa K.; Christiansen, Helena E.

    2017-12-14

    In previous tests of the effectiveness of four common fish screen materials for excluding lamprey ammocoetes, we determined that woven wire (WW) allowed substantially more entrainment than perforated plate (PP), profile bar (PB), or Intralox (IL) material. These tests were simplistic because they used small vertically-oriented screens positioned perpendicular to the flow without a bypass or a sweeping velocity (SV). In the subsequent test discussed in this report, we exposed ammocoetes to much larger (2.5-m-wide) screen panels with flows up to 10 ft3 /s, a SV component, and a simulated bypass channel. The addition of a SV modestly improved protection of lamprey ammocoetes for all materials tested. A SV of 35 cm/s with an approach velocity (AV) of 12 cm/s, was able to provide protection for fish about 5–15 mm smaller than the protection provided by an AV of 12 cm/s without a SV component. The best-performing screen panels (PP, IL, and PB) provided nearly complete protection from entrainment for fish greater than 50-mm toal length, but the larger openings in the WW material only protected fish greater than 100-mm total length. Decreasing the AV and SV by 50 percent expanded the size range of protected lampreys by about 10–15 mm for those exposed to IL and WW screens, and it decreased the protective ability of PP screens by about 10 mm. Much of the improvement for IL and WW screens under the reduced flow conditions resulted from an increase in the number of lampreys swimming away from the screen. Fish of all sizes became impinged (that is, stuck on the screen surface for more than 1 s) on the screens, with the rate of impingement highest on PP (39– 72 percent) and lowest on WW (7–22 percent). Although impingements were common, injuries were rare, and 24-h post-test survival was greater than 99 percent. Our results refined the level of protection provided by these screen materials when both an AV and SV are present and confirmed our earlier recommendation that WW screens be replaced with more effective materials. Future work should focus on determining the risks associated with other screen types (for example, rotary drum screens, horizontal flat plate screens) and exploring the effectiveness of higher SV:AV ratios, because it may help expand the range of sizes protected by the best performing materials.

  14. Screening of seaweeds in the East China Sea as potential bio-monitors of heavy metals.

    PubMed

    Pan, Yaoru; Wernberg, Thomas; de Bettignies, Thibaut; Holmer, Marianne; Li, Ke; Wu, Jiaping; Lin, Fang; Yu, Yan; Xu, Jiang; Zhou, Chaosheng; Huang, Zhixing; Xiao, Xi

    2018-06-01

    Seaweeds are good bio-monitors of heavy metal pollution and have been included in European coastal monitoring programs. However, data for seaweed species in China are scarce or missing. In this study, we explored the potential of seaweeds as bio-monitor by screening the natural occurring seaweeds in the "Kingdom of seaweed and shellfish" at Dongtou Islands, the East China Sea. Totally, 12 seaweed species were collected from six sites, with richness following the sequence of Rhodophyta > Phaeophyta > Chlorophyta. The concentration of heavy metals (Cu, Cr, Ni, Zn, Pb, Cd, As) in the seaweeds was determined, and the bioaccumulation coefficient was calculated. A combination of four seaweeds, Pachydictyon coriaceum, Gelidium divaricatum, Sargassum thunbergii, and Pterocladiella capillacea, were proposed as bio-monitors due to their high bioaccumulation capabilities of specific heavy metals in the East China Sea and hence hinted the importance of using seaweed community for monitoring of pollution rather than single species. Our results provide first-hand data for the selection of bio-monitor species for heavy metals in the East China Sea and contribute to selection of cosmopolitan bio-monitor communities over geographical large area, which will benefit the establishment of monitoring programs for coastal heavy metal contamination.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teplitsky, Ella; Joshi, Karan; Ericson, Daniel L.

    We describe a high throughput method for screening up to 1728 distinct chemicals with protein crystals on a single microplate. Acoustic droplet ejection (ADE) was used to co-position 2.5 nL of protein, precipitant, and chemicals on a MiTeGen in situ-1 crystallization plate™ for screening by co-crystallization or soaking. ADE-transferred droplets follow a precise trajectory which allows all components to be transferred through small apertures in the microplate lid. The apertures were large enough for 2.5 nL droplets to pass through them, but small enough so that they did not disrupt the internal environment created by the mother liquor. Using thismore » system, thermolysin and trypsin crystals were efficiently screened for binding to a heavy-metal mini-library. Fluorescence and X-ray diffraction were used to confirm that each chemical in the heavy-metal library was correctly paired with the intended protein crystal. Moreover, a fragment mini-library was screened to observe two known lysozyme We describe a high throughput method for screening up to 1728 distinct chemicals with protein crystals on a single microplate. Acoustic droplet ejection (ADE) was used to co-position 2.5 nL of protein, precipitant, and chemicals on a MiTeGen in situ-1 crystallization plate™ for screening by co-crystallization or soaking. ADE-transferred droplets follow a precise trajectory which allows all components to be transferred through small apertures in the microplate lid. The apertures were large enough for 2.5 nL droplets to pass through them, but small enough so that they did not disrupt the internal environment created by the mother liquor. Using this system, thermolysin and trypsin crystals were efficiently screened for binding to a heavy-metal mini-library. Fluorescence and X-ray diffraction were used to confirm that each chemical in the heavy-metal library was correctly paired with the intended protein crystal. A fragment mini-library was screened to observe two known lysozyme ligands using both co-crystallization and soaking. A similar approach was used to identify multiple, novel thaumatin binding sites for ascorbic acid. This technology pushes towards a faster, automated, and more flexible strategy for high throughput screening of chemical libraries (such as fragment libraries) using as little as 2.5 nL of each component.ds using both co-crystallization and soaking. We used a A similar approach to identify multiple, novel thaumatin binding sites for ascorbic acid. This technology pushes towards a faster, automated, and more flexible strategy for high throughput screening of chemical libraries (such as fragment libraries) using as little as 2.5 nL of each component.« less

  16. Using bacterial inclusion bodies to screen for amyloid aggregation inhibitors.

    PubMed

    Villar-Piqué, Anna; Espargaró, Alba; Sabaté, Raimon; de Groot, Natalia S; Ventura, Salvador

    2012-05-03

    The amyloid-β peptide (Aβ42) is the main component of the inter-neuronal amyloid plaques characteristic of Alzheimer's disease (AD). The mechanism by which Aβ42 and other amyloid peptides assemble into insoluble neurotoxic deposits is still not completely understood and multiple factors have been reported to trigger their formation. In particular, the presence of endogenous metal ions has been linked to the pathogenesis of AD and other neurodegenerative disorders. Here we describe a rapid and high-throughput screening method to identify molecules able to modulate amyloid aggregation. The approach exploits the inclusion bodies (IBs) formed by Aβ42 when expressed in bacteria. We have shown previously that these aggregates retain amyloid structural and functional properties. In the present work, we demonstrate that their in vitro refolding is selectively sensitive to the presence of aggregation-promoting metal ions, allowing the detection of inhibitors of metal-promoted amyloid aggregation with potential therapeutic interest. Because IBs can be produced at high levels and easily purified, the method overcomes one of the main limitations in screens to detect amyloid modulators: the use of expensive and usually highly insoluble synthetic peptides.

  17. Anomalous spectral-weight transfers unraveling oxygen screening and electronic correlations in the insulator-metal transition of VO2

    NASA Astrophysics Data System (ADS)

    Yeo, L. H.; Srivastava, A.; Majidi, M. A.; Sutarto, R.; He, F.; Poh, S. M.; Diao, C.; Yu, X.; Motapothula, M.; Saha, S.; Ojha, S.; Kanjilal, D.; Trevisanutto, P. E.; Breese, M. B. H.; Venkatesan, T.; Rusydi, A.

    2015-02-01

    Vanadium dioxide (VO2) undergoes an unusual insulator-metal transition (IMT), and after decades of study, the origin of the IMT remains hotly debated. Here, by analyzing spectral-weight transfers (SWTs) of x-ray absorption spectroscopy at the V L3 ,2 and O K edges on specially designed VO2 films, we observe d||(dx2-y2) band splitting at the V L3 ,2 edges across the IMT, accompanied by anomalous SWTs as high as ˜12 eV at the O K edge, indicating strong electronic correlations. Surprisingly, a few oxygen vacancies induce dramatic SWTs at the O K edge, but the sample remains conducting. Supported by theoretical calculations, we find that in the metallic state, direct V (3 d∥) -V(3 d∥) and O(2 p ) -V(3 d∥) hybridized orbital correlations are screened by O(2 p ) -V(3 dπ) hybridized orbitals, while in the insulating state they are strongly correlated due to changes in the oxygen orbital occupancy. Our result shows the importance of screenings and electronic correlations for IMTs in VO2.

  18. Surface plasmon resonances of arbitrarily shaped nanometallic structures in the small-screening-length limit

    PubMed Central

    Giannini, Vincenzo; Maier, Stefan A.; Craster, Richard V.

    2016-01-01

    According to the hydrodynamic Drude model, surface plasmon resonances of metallic nanostructures blueshift owing to the non-local response of the metal’s electron gas. The screening length characterizing the non-local effect is often small relative to the overall dimensions of the metallic structure, which enables us to derive a coarse-grained non-local description using matched asymptotic expansions; a perturbation theory for the blueshifts of arbitrary-shaped nanometallic structures is then developed. The effect of non-locality is not always a perturbation and we present a detailed analysis of the ‘bonding’ modes of a dimer of nearly touching nanowires where the leading-order eigenfrequencies and eigenmode distributions are shown to be a renormalization of those predicted assuming a local metal permittivity. PMID:27493575

  19. Self-Expanding Metal Stents Improve Swallowing and Maintain Nutrition During Neoadjuvant Therapy for Esophageal Cancer.

    PubMed

    Smith, Zachary L; Gonzaga, Jason E; Haasler, George B; Gore, Elizabeth M; Dua, Kulwinder S

    2017-06-01

    Patients with locally advanced esophageal cancer can have significant dysphagia. Nutritional support during neoadjuvant therapy is often delivered via nasoenteric or percutaneous feeding tubes. These approaches do not allow for per-oral feeding. Evaluate the safety and efficacy of fully covered self-expanding metal esophageal stents for nutritional support during neoadjuvant therapy. This was a pilot, prospective study at a single tertiary center. From March 2012 to May 2013, consecutive patients with esophageal cancer eligible for neoadjuvant therapy were enrolled. Metal stents were placed prior to starting neoadjuvant therapy. Data were collected at baseline and predetermined intervals until an endpoint (surgery or disease progression). Outcomes included dysphagia grade, satisfaction of swallowing score, nutritional status (weight, serum albumin), impact on surgery, and adverse events. Fourteen stents were placed in 12 patients (59.1 ± 9.5 years, 11 men, 1 woman). Dysphagia grade (pre 3.4 ± 0.5 vs post 0.2 ± 0.4, p < 0.0001) and swallowing scores (20.2 ± 5.9 vs 6.3 ± 4.7, p < 0.0001) significantly improved after stent placement. Improvements were sustained throughout neoadjuvant therapy. Body weight and serum albumin levels remained stable. Adverse events included severe chest pain (2), food impaction (1), and delayed stent migration (2). Five patients underwent surgical resection. No significant chemoradiation or operative adverse events occurred due to the presence of a stent. During neoadjuvant therapy for esophageal cancer, self-expanding metal stents are safe and effective in relieving dysphagia and maintaining nutrition. They allow patients to eat orally, thereby improving patient satisfaction. The presence of an in situ stent did not interfere with surgery.

  20. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.

    PubMed

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-10-01

    Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p = 0.005). Karnofsky performance status (p = 0.04), no presence of ascites (p = 0.02), and insufficient (<30%) stent expansion (p = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length (p = 0.05) and chemotherapy (p = 0.03) were predictors of C-SEMS migration. Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).

  1. Application of self-expandable metal stents for ureteroileal anastomotic strictures: long-term results.

    PubMed

    Liatsikos, Evangelos N; Kagadis, George C; Karnabatidis, Dimitrios; Katsanos, Konstantinos; Papathanassiou, Zafiria; Constantinides, Constantinos; Perimenis, Petros; Nikiforidis, George C; Stolzenburg, Jens-Uwe; Siablis, Dimitrios

    2007-07-01

    We report our long-term experience with the management of benign ureteroileal anastomotic strictures using self-expandable metal stents. A total of 16 male and 2 female patients with a mean+/-SD age of 72+/-7 years (range 66 to 78) with benign fibrotic strictures at the site of ureteroileal anastomosis underwent implantation of self-expandable metal stents with a nominal diameter of 6 to 8 mm. A total of 24 ureteroileal conduits were treated. The external nephrostomy tubes were removed after fluoroscopic validation of ureteral patency. Patients were followed with blood biochemistry, ultrasonography, urography and/or virtual endoscopy. Retrograde external-internal catheter insertion through the cutaneous stoma was performed in cases of recalcitrant stricture. The technical success rate of ureteroileal stricture crossing and stenting was 100% (24 of 24 cases). Mean followup was 21 months (range 7 to 50). The clinical success rate during the immediate post-stenting period was 70.8% (17 of 24 cases). The 1 and 4-year primary patency rates were 37.8% and 22.7%, respectively. Secondary interventions included repeat balloon dilation in 15 ureters, of which 8 also underwent subsequent coaxial stent placement. The 1 and 4-year secondary patency rates were 64.8% and 56.7%, respectively. Except in 2 patients who died external-internal Double-J catheters continued to be inserted retrograde in 6 ureteroileal conduits. They are periodically exchanged to prevent mucous inspissation and stent encrustation. Metal stents served as the definitive treatment for stricture in more than half of the cases, whereas in the remainder the stents allowed the uncomplicated and regular exchange of Double-J catheters in retrograde fashion. This combined, less invasive treatment for ureteroileal anastomotic strictures may help patients avoid surgical revision and preserve quality of life.

  2. Thermodynamics of Thomas-Fermi screened Coulomb systems

    NASA Technical Reports Server (NTRS)

    Firey, B.; Ashcroft, N. W.

    1977-01-01

    We obtain in closed analytic form, estimates for the thermodynamic properties of classical fluids with pair potentials of Yukawa type, with special reference to dense fully ionized plasmas with Thomas-Fermi or Debye-Hueckel screening. We further generalize the hard-sphere perturbative approach used for similarly screened two-component mixtures, and demonstrate phase separation in this simple model of a liquid mixture of metallic helium and hydrogen.

  3. Chapter 14. Approaches for Evaluation of Mode of Action.

    EPA Science Inventory

    Cellular and molecular approaches vastly expand the possibilities for revealing the underlying mechanisms of developmental toxicity. The typical teratology screening test examines near-term fetuses after exposure throughout organogenesis and evaluates the potential for an exposur...

  4. Expanded HIV Screening Projected to Decrease Spread of the Virus

    MedlinePlus

    ... Alcohol Club Drugs Cocaine Fentanyl Hallucinogens Inhalants Heroin Marijuana MDMA (Ecstasy/Molly) Methamphetamine Opioids Over-the-Counter ... Illegal Drugs Inhalants K2/Spice Kratom LSD (Acid) Marijuana MDMA (Ecstasy) Methamphetamine Opioids Other Drugs Over-the- ...

  5. Environmental availability of chlorinated organics, explosives, and metals in soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, W.C.; Loehr, R.C.; Smith, B.P.

    1999-08-01

    Environmental availability is key to defining the extent of remediation required. Nationally recognized experts summarize what is known about the environmental availability of chlorinated organics (Perry McCarty), explosives (Judith Pennington), and metals (Rufus Chaney). It also summarizes the current use of environmental availability to set cleanup goals for petroleum hydrocarbons and identifies essential research needed to expand the knowledge base for environmental availability.

  6. Materials development and evaluation for the ceramic helical expander

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landingham, R.L.; Taylor, R.W.

    The supporting role of the materials program for the ceramic helical expander program is described. The materials problems for this rotory expander in an extremely severe environment-a direct coal-fired Brayton topping cycle is defined. Readily available materials and methods for possible solution to these material problems as well as initiating some longer-range studies to improve reliability were evaluated. A preliminary screening of materials in hot coal-fired environments to select candidate materials and coating was made. More detailed evaluations of these candidate materials-reaction-bonded silicon nitride (RBSN) and Si--Al--O--N (Sialon) system- and coatings-chemical-vapor-deposited silicon nitride (CVD-Si/sub 3/N/sub 4/) and CVD-Sialon need tomore » be performed. Termination of the helical expander program abruptly stopped the materials program during this evaluation.« less

  7. Materials development and evaluation for the ceramic helical expander

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landingham, R.L.; Taylor, R.W.

    The supporting role of the materials program for the ceramic helical expander program is described. The materials problems for this rotory expander in an extremely severe environment - a direct coal-fired Brayton topping cycle is defined. Readily available materials and methods are evaluated for possible solution to these material problems as well as initiating some longer-range studies to improve reliability. A preliminary screening of materials in hot coal-fired environments to select candidate materials and coating, was made, but there is a need to perform more detailed evaluations of these candidate materials-reaction-bonded silicon nitride (RBSN) and Si--Al--O--N (Sialon) system- and coatings-chemical-vapor-depositedmore » silicon nitride (CVD-Si/sub 3/N/sub 4/) and CVD-Sialon. Termination of the helical expander program abruptly stopped the materials program during this evaluation.« less

  8. Proper Exercise and Nutrition kit: use of obesity screening and assessment tools with underserved populations.

    PubMed

    Kopp, Mary K; Hornberger, Cynthia

    2008-02-01

    Additional efforts are needed to assist public health, school, and clinic-based pediatric nurses in identifying the prevalence of obesity among Kansas Medicaid-eligible children, 21 years or younger. A Proper Exercise and Nutrition (PEN) tool kit was mailed to 500 public health nurses who performed KAN Be Healthy (KBH) assessments. KBH nurses were provided an expanded training curriculum on growth, nutrition, and obesity along with appropriate screening tools. Nurses were surveyed about their current assessment practices and general knowledge of obese clients. After the PEN tool kit distribution, nurses reported an increased use of screening tools and standardized referral parameters. This program intervention was successful in changing nursing practice, resulting in evidence-based understanding of obesity screening and assessment.

  9. Electron screening in nickel

    NASA Astrophysics Data System (ADS)

    Gajević, Jelena; Cvetinović, Aleksandra; Likar, Andrej; Lipoglavšek, Matej; Pelicon, Primož; Petrovič, Toni; Sánchez Ortiz, Alberto

    2013-06-01

    In order to investigate the interplay between nuclei and their surroundings, we studied proton-induced nuclear reactions over an energy range from 0.86 to 3.08MeV for different environments: Ni metal and NiO insulator. The measurements were based on the observation of the yields of 59, 61, 63, 64, 65Cu and 58, 60, 62Ni de-excitation γ-rays. Shifts in the resonance energy for the metallic target relative to the insulator one were not observed. Electron screening potential of Ue=31± 13 keV was deduced for 64Ni (p,nγ ) 64Cu reaction, while Ue=19± 4 keV was deduced for 58Ni(p,γ ) 59Cu and 60Ni(p,γ ) 61Cu reactions. The observed electron screening potentials for (p,n) and (p,γ) reactions are the same within error bars, but the comparison with previous measurements raises the question of the independence of the electron screening from the reaction exit channel.

  10. The biogeochemical distribution of trace elements in the Indian Ocean

    NASA Astrophysics Data System (ADS)

    Saager, Paul M.

    1994-06-01

    The present review deals with the distributions of dissolved trace metals in the Indian Ocean in relation with biological, chemical and hydrographic processes. The literature data-base is extremely limited and almost no information is available on particle processes and input and output processes of trace metals in the Indian Ocean basin and therefore much research is needed to expand our understanding of the marine chemistries of most trace metals. An area of special interest for future research is the Arabian Sea. The local conditions (upwelling induced productivity, restricted bottom water circulation and suboxic intermediate waters) create a natural laboratory for studying trace metal chemistry.

  11. Design, Fabrication and Test of a Formation of Two Satellites Connected by a Tether

    DTIC Science & Technology

    2007-08-03

    Device (PMD), consisting of filters and screens , will be integrated into this tank. The shell is manufactured with Stainless Steel 316L with the...internal filters manufactured with Stainless Steel 304L/316L. The internal screens are of expanded aluminum 901A. Table 4 highlights the specifications of...Final Report Submitted to the Air Force Office of Scientific Research University Nanosat Program August 3, 2007 Dr. Kent Miller AFOSR/NE 4015 Wilson

  12. Assessing local capacity to expand rural breast cancer screening and patient navigation: An iterative mixed-method tool.

    PubMed

    Inrig, Stephen J; Higashi, Robin T; Tiro, Jasmin A; Argenbright, Keith E; Lee, Simon J Craddock

    2017-04-01

    Despite federal funding for breast cancer screening, fragmented infrastructure and limited organizational capacity hinder access to the full continuum of breast cancer screening and clinical follow-up procedures among rural-residing women. We proposed a regional hub-and-spoke model, partnering with local providers to expand access across North Texas. We describe development and application of an iterative, mixed-method tool to assess county capacity to conduct community outreach and/or patient navigation in a partnership model. Our tool combined publicly-available quantitative data with qualitative assessments during site visits and semi-structured interviews. Application of our tool resulted in shifts in capacity designation in 10 of 17 county partners: 8 implemented local outreach with hub navigation; 9 relied on the hub for both outreach and navigation. Key factors influencing capacity: (1) formal linkages between partner organizations; (2) inter-organizational relationships; (3) existing clinical service protocols; (4) underserved populations. Qualitative data elucidate how our tool captured these capacity changes. Our capacity assessment tool enabled the hub to establish partnerships with county organizations by tailoring support to local capacity and needs. Absent a vertically integrated provider network for preventive services in these rural counties, our tool facilitated a virtually integrated regional network to extend access to breast cancer screening to underserved women. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Alkali metal vapors - Laser spectroscopy and applications

    NASA Technical Reports Server (NTRS)

    Stwalley, W. C.; Koch, M. E.

    1980-01-01

    The paper examines the rapidly expanding use of lasers for spectroscopic studies of alkali metal vapors. Since the alkali metals (lithium, sodium, potassium, rubidium and cesium) are theoretically simple ('visible hydrogen'), readily ionized, and strongly interacting with laser light, they represent ideal systems for quantitative understanding of microscopic interconversion mechanisms between photon (e.g., solar or laser), chemical, electrical and thermal energy. The possible implications of such understanding for a wide variety of practical applications (sodium lamps, thermionic converters, magnetohydrodynamic devices, new lasers, 'lithium waterfall' inertial confinement fusion reactors, etc.) are also discussed.

  14. Functional microporous materials of metal carboxylate: Gas-occlusion properties and catalytic activities

    NASA Astrophysics Data System (ADS)

    Mori, Wasuke; Sato, Tomohiko; Ohmura, Tesushi; Nozaki Kato, Chika; Takei, Tohru

    2005-08-01

    Copper(II) terephthalate is the first transition metal complex found capable of adsorbing gases. This complex has opened the new field of adsorbent complex chemistry. It is recognized as the lead complex in the construction of microporous complexes. This specific system has been expanded to a systematic series of derivatives of other isomorphous transition metals, molybdenum(II), ruthenium(II, III), and rhodium(II). These complexes with open frameworks are widely recognized as very useful materials for applications to catalysis, separation at molecular level, and gas storage.

  15. Nonlocal screening in metal surfaces

    NASA Technical Reports Server (NTRS)

    Krotscheck, E.; Kohn, W.

    1986-01-01

    Due to the effect of the nonuniform environment on the static screening of the Coulomb potential, the local-density approximation for the particle-hole interaction is found to be inadequate to determine the surface energy of simple metals. Use of the same set of single-particle states, and thus the same one-body density and the same work function, has eliminated the single-electron states in favor of the structure of the short-ranged correlations as the basis of this effect. A posteriori simplifications of the Fermi hypernetted-chain theory may be found to allow the same calculational accuracy with simpler computational tools.

  16. Electrostatic energy and screened charge interaction near the surface of metals with different Fermi surface shape

    NASA Astrophysics Data System (ADS)

    Gabovich, A. M.; Il'chenko, L. G.; Pashitskii, E. A.; Romanov, Yu. A.

    1980-04-01

    Using the Poisson equation Green function for a self-consistent field in a spatially inhomogeneous system, expressions for the electrostatic energy and screened charge interaction near the surface of a semi-infinite metal and a thin quantizing film are derived. It is shown that the decrease law and Friedel oscillation amplitude of adsorbed atom indirect interaction are determined by the electron spectrum character and the Fermi surface shape. The results obtained enable us to explain, in particular, the submonolayer adsorbed film structure on the W and Mo surfaces.

  17. Microelectronic components and metallic oxide studies and applications

    NASA Technical Reports Server (NTRS)

    Williams, L., Jr.

    1976-01-01

    The project involved work in two basic areas: (1) Evaluation of commercial screen printable thick film conductors, resistors, thermistors and dielectrics as well as alumina substrates used in hybird microelectronics industries. Results of tests made on materials produced by seven companies are presented. (2) Experimental studies on metallic oxides of copper and vanadium, in an effort to determine their electrochemical properties in crystalline, powder mixtures and as screen printable thick films constituted the second phase of the research effort. Oxide investigations were aimed at finding possible applications of these materials as switching devices memory elements and sensors.

  18. CRISPR-UMI: single-cell lineage tracing of pooled CRISPR-Cas9 screens.

    PubMed

    Michlits, Georg; Hubmann, Maria; Wu, Szu-Hsien; Vainorius, Gintautas; Budusan, Elena; Zhuk, Sergei; Burkard, Thomas R; Novatchkova, Maria; Aichinger, Martin; Lu, Yiqing; Reece-Hoyes, John; Nitsch, Roberto; Schramek, Daniel; Hoepfner, Dominic; Elling, Ulrich

    2017-12-01

    Pooled CRISPR screens are a powerful tool for assessments of gene function. However, conventional analysis is based exclusively on the relative abundance of integrated single guide RNAs (sgRNAs) between populations, which does not discern distinct phenotypes and editing outcomes generated by identical sgRNAs. Here we present CRISPR-UMI, a single-cell lineage-tracing methodology for pooled screening to account for cell heterogeneity. We generated complex sgRNA libraries with unique molecular identifiers (UMIs) that allowed for screening of clonally expanded, individually tagged cells. A proof-of-principle CRISPR-UMI negative-selection screen provided increased sensitivity and robustness compared with conventional analysis by accounting for underlying cellular and editing-outcome heterogeneity and detection of outlier clones. Furthermore, a CRISPR-UMI positive-selection screen uncovered new roadblocks in reprogramming mouse embryonic fibroblasts as pluripotent stem cells, distinguishing reprogramming frequency and speed (i.e., effect size and probability). CRISPR-UMI boosts the predictive power, sensitivity, and information content of pooled CRISPR screens.

  19. iss050e037906

    NASA Image and Video Library

    2017-02-02

    iss050e037906 (02/02/2017) --- NASA astronaut Peggy Whitson (left) and ESA (European Space Agency) astronaut Thomas Pesquet are photographed inside the Bigelow Expandable Activity Module, or BEAM. BEAM is an experimental expandable module attached to the station. Expandable habitats could greatly decrease the amount of transport volume for future space missions. These “expandables” weigh less and take up less room than traditional rigid metal habitats on a rocket while allowing additional space for living and working. They also provide protection from solar and cosmic radiation, space debris, and other contaminants. Crews traveling to the moon, Mars, asteroids, or other destinations could potentially use them as habitable structures.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, H., E-mail: li-huanglong@mail.tsinghua.edu.cn; Gillen, R.; Robertson, J., E-mail: jr214@cam.ac.uk

    The screened exchange (sX) hybrid functional has been widely used in computational material science. Although it has widely been studied in bulk systems, less is known about its functional behavior in surface systems which are crucial to many technologies such as materials synthesis and nano-electronic devices. Assessing the screening dependent functional behaviors in the surface systems is therefore important for its application in such systems. In this work, we investigate the screening effects of the sX in CO adsorption on Pt(111) surface. The differences between the sX and Heyd-Scuseria-Ernzerhof (HSE06) hybrid functionals, and the effects of screening parameters are studied.more » The screening has two effects: first, the HOMO-LUMO gap is screening dependent. This affects the site preference most significantly. In this work, atop adsorption of CO/Pt(111) is predicted by the hybrid functionals with screened exchange potential. The sX(1.44) gives the largest HOMO-LUMO gap for the isolated CO molecule. The adsorption energy difference between the atop and fcc site is also the largest by the sX(1.44) which is explained by the reduced metal d states to the CO 2π* state back-donation, with stronger effect for the fcc adsorption than for the atop adsorption; second, the adsorption energy is screening dependent. This can be seen by comparing the sX(2.38) and HSE06 which have different screening strengths. They show similar surface band structures for the CO adsorption but different adsorption energies, which is explained by the stronger CO 5σ state to the metal d states donation or the effectively screened Pauli repulsion. This work underlines the screening strength as a main difference between sX and HSE06, as well as an important hybrid functional parameter for surface calculation.« less

  1. Ethical issues in pediatric genetic testing and screening.

    PubMed

    Botkin, Jeffrey R

    2016-12-01

    Developments in genetic test technologies enable a detailed analysis of the genomes of individuals across the range of human development from embryos to adults with increased precision and lower cost. These powerful technologies raise a number of ethical issues in pediatrics, primarily because of the frequent lack of clinical utility of genetic information, the generation of secondary results and questions over the proper scope of parental authority for testing. Several professional organizations in the fields of genetics and pediatrics have published new guidance on the ethical, legal, and policy issues relevant to genetic testing in children. The roles of predictive testing for adult-onset conditions, the management of secondary findings and the role of informed consent for newborn screening remain controversial. However, research and experience are not demonstrating serious adverse psychosocial impacts from genetic testing and screening in children. The use of these technologies is expanding with the notion that the personal utility of test results, rather than clinical utility, may be sufficient to justify testing. The use of microarray and genome sequencing technologies is expanding in the care of children. More deference to parental decision-making is evolving in contexts wherein information and counseling can be made readily available.

  2. Pancreatic cancer early detection: Expanding higher-risk group with clinical and metabolomics parameters

    PubMed Central

    Urayama, Shiro

    2015-01-01

    Pancreatic ductal adenocarcinoma (PDAC) is the fourth and fifth leading cause of cancer death for each gender in developed countries. With lack of effective treatment and screening scheme available for the general population, the mortality rate is expected to increase over the next several decades in contrast to the other major malignancies such as lung, breast, prostate and colorectal cancers. Endoscopic ultrasound, with its highest level of detection capacity of smaller pancreatic lesions, is the commonly employed and preferred clinical imaging-based PDAC detection method. Various molecular biomarkers have been investigated for characterization of the disease, but none are shown to be useful or validated for clinical utilization for early detection. As seen from studies of a small subset of familial or genetically high-risk PDAC groups, the higher yield and utility of imaging-based screening methods are demonstrated for these groups. Multiple recent studies on the unique cancer metabolism including PDAC, demonstrate the potential for utility of the metabolites as the discriminant markers for this disease. In order to generate an early PDAC detection screening strategy available for a wider population, we propose to expand the population of higher risk PDAC group with combination clinical and metabolomics parameters. PMID:25684935

  3. Decline in Cancer Screening in Vulnerable Populations? Results of the EDIFICE Surveys.

    PubMed

    Morère, Jean-François; Eisinger, François; Touboul, Chantal; Lhomel, Christine; Couraud, Sébastien; Viguier, Jérôme

    2018-03-05

    We studied cancer screening over time and social vulnerability via surveys of representative populations. Individuals aged 50-75 years with no personal history of cancer were questioned about lifetime participation in screening tests, compliance (adherence to recommended intervals [colorectal, breast and cervical cancer]) and opportunistic screening (prostate and lung cancer). The proportion of vulnerable/non-vulnerable individuals remained stable between 2011 and 2016. In 2011, social vulnerability had no impact on screening participation, nor on compliance. In 2014, however, vulnerability was correlated with less frequent uptake of colorectal screening (despite an organised programme) and prostate cancer screening (opportunistic), and also with reduced compliance with recommended intervals (breast and cervical cancer screening). In 2016, the trends observed in 2014 were substantiated and even extended to breast, colorectal and cervical cancer screening uptakes. Social vulnerability has an increasingly negative impact on cancer screening attendance. The phenomenon was identified in 2014 and had expanded by 2016. Although organised programmes have been shown to ensure equitable access to cancer screening, this remains a precarious achievement requiring regular monitoring. Further studies should focus on attitudes of vulnerable populations and on ways to improve cancer awareness campaigns.

  4. Models of Community-Based Hepatitis B Surface Antigen Screening Programs in the U.S. and Their Estimated Outcomes and Costs

    PubMed Central

    Rein, David B.; Lesesne, Sarah B.; Smith, Bryce D.; Weinbaum, Cindy M.

    2011-01-01

    Objectives Information on the process and method of service delivery is sparse for hepatitis B surface antigen (HBsAg) testing, and no systematic study has evaluated the relative effectiveness or cost-effectiveness of different HBsAg screening models. To address this need, we compared five specific community-based screening programs. Methods We funded five HBsAg screening programs to collect information on their design, costs, and outcomes of participants during a six-month observation period. We categorized programs into four types of models. For each model, we calculated the number screened, the number screened as per Centers for Disease Control and Prevention (CDC) recommendations, and the cost per screening. Results The models varied by cost per person screened and total number of people screened, but they did not differ meaningfully in the proportion of people screened following CDC recommendations, the proportion of those screened who tested positive, or the proportion of those who newly tested positive. Conclusions Integrating screening into outpatient service settings is the most cost-effective method but may not reach all people needing to be screened. Future research should examine cost-effective methods that expand the reach of screening into communities in outpatient settings. PMID:21800750

  5. Conduction in fully ionized liquid metals

    NASA Technical Reports Server (NTRS)

    Stevenson, D. J.; Ashcroft, N. W.

    1973-01-01

    Electron transport is considered in high density fully ionized liquid metals. Ionic structure is described in terms of hard-sphere correlation functions and the scattering is determined from self-consistently screened point ions. Applications to the physical properties of the deep interior of Jupiter are briefly considered.

  6. Material dependence of 2H(d,p)3H cross section at the very low energies

    NASA Astrophysics Data System (ADS)

    Kılıç, Ali İhsan; Czerski, Konrad; Kuştan-Kılıç, Fadime; Targosz-Sleczka, Natalia; Weissbach, Daniel; Huke, Armin; Ruprecht, Götz

    2017-09-01

    Calculations of the material dependence of 2H(d,p)3H cross section and neutron-to-proton branching ratio of d+d reactions have been performed including a concept of the 0+ threshold single particle resonance. The resonance has been assumed to explain the enhanced electron screening effect observed in the d+d reaction for different metallic targets. Here, we have included interference effects between the flat and resonance part of the cross section, which allowed us to enlighten observed suppression of the neutron channel in some metals such as Sr and Li. Since the position of the resonance depends on the screening energy that strongly depends on the local electron density. The resonance width, observed for the d+d reactions in the very hygroscopic metals (Sr and Li) and therefore probably contaminated by oxides, should be much larger than for other metals. Thus, the interference term of the cross section depending on the total resonance width provides the material dependences.

  7. Postage stamp-sized array sensor for the sensitive screening test of heavy-metal ions.

    PubMed

    Zhang, Yu; Li, Xiao; Li, Hui; Song, Ming; Feng, Liang; Guan, Yafeng

    2014-10-07

    The sensitive determination of heavy-metal ions has been widely investigated in recent years due to their threat to the environment and to human health. Among various analytical detection techniques, inexpensive colorimetric testing papers/strips play a very important role. The limitation, however, is also clear: the sensitivity is usually low and the selectivity is poor. In this work, we have developed a postage stamp-sized array sensor composed of nine commercially available heterocyclic azo indicators. Combining filtration-based enrichment with an array of technologies-based pattern-recognition, we have obtained the discrimination capability for seven heavy-metal ions (Hg(2+), Pb(2+), Ag(+), Ni(2+), Cu(2+), Zn(2+), and Co(2+)) at their Chinese wastewater discharge standard concentrations. The allowable detection level of Hg(2+) was down to 0.05 mg L(-1). The heavy-metal ions screening test was readily achieved using a standard chemometric approach. And the array sensor applied well in real water samples.

  8. New tools and approaches to newborn screening: ready to open Pandora's box?

    PubMed

    Ficicioglu, Can

    2017-05-01

    The landscape of newborn screening (NBS) is changing as new tools are developed. We must acknowledge that NBS is a very important and extraordinarily positive initiative especially for rare and serious inherited disorders; however, lessons learned from current NBS should guide the future of NBS as we enter the era of "omics" that will expand NBS for many other genetic disorders. In this article, I will first discuss new tools such as genomics and metabolomics for NBS. I will then turn to assessing how best to take advantage of new technical developments while considering the best interests of patients and the success of newborn screening.

  9. Expanded carrier screening: what determines intended participation and can this be influenced by message framing and narrative information?

    PubMed

    Voorwinden, Jan S; Buitenhuis, Anne H; Birnie, Erwin; Lucassen, Anneke M; Verkerk, Marian A; van Langen, Irene M; Plantinga, Mirjam; Ranchor, Adelita V

    2017-06-01

    Next-generation sequencing enabled us to create a population-based expanded carrier screening (ECS) test that simultaneously tests for 50 serious autosomal recessive diseases. Before offering this test universally, we wanted to know what factors are related to intended participation and how the general public can be informed about the test without being influenced in their intention to participate. We studied this by measuring to what extent 'message framing' and 'narrative information' can influence people's intended participation. Data were collected by means of an online survey of 504 potential users, and the factors examined were based on the Theory of Planned Behaviour and on previous research on intended participation in preconception carrier screening. Message framing was manipulated by explaining the risk of couple carriership in different ways, while narrative information was provided to only half of the respondents. The factors most positively related to intended participation were perceiving benefits of the screening, having a positive attitude towards the screening, having no religion, having an actual child wish and experiencing the choice to participate as easy. Perceived benefits and a positive attitude were most influential factors by far. Message framing and narrative information had no significant effect on intended participation, reinforcing that message framing and narrative information can help to inform the general public about ECS without influencing their intended participation. Future research should study if the importance of perceived benefits and a positive attitude can be replicated when other factors are included and when actual participation is measured instead of intended participation.

  10. Health-care providers' views on pursuing reproductive benefit through newborn screening: the case of sickle cell disorders

    PubMed Central

    Bombard, Yvonne; Miller, Fiona A; Hayeems, Robin Z; Wilson, Brenda J; Carroll, June C; Paynter, Martha; Little, Julian; Allanson, Judith; Bytautas, Jessica P; Chakraborty, Pranesh

    2012-01-01

    Newborn screening (NBS) programs aim to identify affected infants before the onset of treatable disorders. Historically, benefits to the family and society were considered secondary to this clinical benefit; yet, recent discourse defending expanded NBS has argued that screening can in part be justified by secondary benefits, such as learning reproductive risk information to support family planning (‘reproductive benefit'). Despite increased attention to these secondary benefits of NBS, stakeholders' values remain unknown. We report a mixed methods study that included an examination of providers' views toward the pursuit of reproductive risk information through NBS, using sickle cell disorder carrier status as an example. We surveyed a stratified random sample of 1615 providers in Ontario, and interviewed 42 providers across 7 disciplines. A majority endorsed the identification of reproductive risks as a goal of NBS (74–77%). Providers' dominant rationale was that knowledge of carrier status is an important and inherent benefit of NBS as it allows people to make reproductive choices, which is consistent with the goals of disease prevention. However, some challenged its appropriateness, questioning its logic, timing and impact on disease prevention. Others were sensitive to intruding on individuals' choices or children's independent rights. While the dominant view is consistent with discourse defending expanded NBS, it deviates from the traditional screening principles that underpin most public health interventions. Broader discussion of the balance between benefits to screened individuals and those to families and societies, in the context of public health programs, is needed. PMID:22071888

  11. Development of the electrothermal instability from resistive inclusions

    NASA Astrophysics Data System (ADS)

    Yu, Edmund; Awe, T. J.; Bauer, B. S.; Yates, K. C.; Yelton, W. G.; Hutchinson, T. M.; Fuelling, S.; McKenzie, B. B.; Peterson, K. J.

    2016-10-01

    The magneto Rayleigh-Taylor (MRT) instability limits the performance of all magnetically imploded systems. In the case of compressing metal liners, as in the magnetized liner inertial fusion concept, a dominant seed for MRT is believed to be the electrothermal instability (ETI). Here, linear theory predicts the most unstable mode manifests as horizontal (i.e. perpendicular to current flow) bands of heated and expanded metal. However, how do such bands, known as striations, actually develop from a smooth metal surface? Recent experiments on ETI evolution, performed at the University of Nevada, Reno, provide a possible answer: pre-shot characterization of aluminum rods show numerous resistive inclusions, several microns in diameter and distributed throughout the rod. In this work, we use 3D MHD simulation and analytic theory to explore how current redistribution around these isolated inclusions, combined with ETI, can lead to rapid formation of the global striation structures. Later in time, striations expand and form density perturbations much larger than the initial inclusion size. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the National Nuclear Security Administration under DE-AC04-94AL85000.

  12. Development of an all-metal thick film cost affective metallization system for solar cells

    NASA Technical Reports Server (NTRS)

    Ross, B.

    1981-01-01

    An economical thick film solar cell contact for high volume production of low cost silicon solar array modules was investigated. All metal screenable pastes using base metals were studied. Solar cells with junction depths varying by a factor of 3.3, with and without a deposited oxide coating were used. Cells were screened and fired by a two step firing process. Adhesion and metallurgical results are unsatisfactory. No electrical information is obtained due to inadequate contact adhesion.

  13. Self-expandable metal stent placement in a child for treatment of achalasia after failed Heller myotomy.

    PubMed

    Gugig, Roberto; Muñoz Jurado, Guillermo; Huang, Clifton; Oleas, Roberto; Robles-Medranda, Carlos

    2018-01-01

    Background and study aims  Childhood achalasia treatment remains inconclusive. What is next after myotomy failure? Repeated pneumatic-dilation put patients at greater risk of perforation with possible symptom recurrence. We report on a 12-year-old patient with a 1-year history of achalasia whom underwent Heller myotomy with fundoplication and recurred with symptoms 1 week after surgery. Pneumatic dilatation was considered but not done because of the risk of esophageal perforation. The decision was made to place a fully covered self-expanding metallic stent (FC-SEMS) for 3 months, which resolved the stenosis as confirmed by esophagram. The patient has remained asymptomatic since the procedure was performed 2 years ago. FC-SEMS is an alternative for treatment of refractory achalasia in children who do not respond to conventional treatment.

  14. Bronchoscopic management of critical central airway obstruction by thyroid cancer: Combination airway stenting using tracheal and inverted-Y carinal self-expanding metallic stents

    PubMed Central

    Madan, Karan; Shrestha, Prajowl; Garg, Rakesh; Hadda, Vijay; Mohan, Anant; Guleria, Randeep

    2017-01-01

    Central airway obstruction (CAO) can result from various benign and malignant etiologies. Anaplastic thyroid cancer (ATC) is the most aggressive form of thyroid cancer. Rapid airway compromise is the main cause of death in ATC. We report a patient with ATC who presented with a large neck mass leading to CAO with long segment tracheal and right main bronchial compression and respiratory failure. Urgent Rigid Bronchoscopy was performed for airway stabilization and patient was managed with a combination airway stenting approach. A combination of self expanding, metallic, covered inverted Y and straight tracheal stents was used to stabilize the near complete airway structure. We herein highlight the role of therapeutic rigid bronchoscopy with airway stenting as an efficacious treatment modality for management of malignant CAO. PMID:28360477

  15. Expanding hollow metal rings

    DOEpatents

    Peacock, Harold B [Evans, GA; Imrich, Kenneth J [Grovetown, GA

    2009-03-17

    A sealing device that may expand more planar dimensions due to internal thermal expansion of a filler material. The sealing material is of a composition such that when desired environment temperatures and internal actuating pressures are reached, the sealing materials undergoes a permanent deformation. For metallic compounds, this permanent deformation occurs when the material enters the plastic deformation phase. Polymers, and other materials, may be using a sealing mechanism depending on the temperatures and corrosivity of the use. Internal pressures are generated by either rapid thermal expansion or material phase change and may include either liquid or solid to gas phase change, or in the gaseous state with significant pressure generation in accordance with the gas laws. Sealing material thickness and material composition may be used to selectively control geometric expansion of the seal such that expansion is limited to a specific facing and or geometric plane.

  16. Double-ended ceramic helical-rotor expander

    DOEpatents

    Mohr, Peter B.; Myers, Wendell B.

    1995-01-01

    A ceramic helical rotor expander using a double-ended or tandem herringbone type rotor arrangement with bearing and seal assemblies remote from the hot gas inlets and especially capable of operating at an inlet temperature of above 1100.degree. C. The rotors are solid or hollow and bonded to hollow metal shafts, and mounted in a composite or simple prismatic casing. The rotors, casing and shafts are constructed from low expansivity materials. In the preferred embodiment the rotors are constructed of silicon nitride and the shafts constructed of an molybdenum alloy, with the metal shafts being supported in bearings and secured to synchronizing gears. The rotors and casing may be provided with coolant channels therein, and are constructed to eliminate the problem of end leakages at inlet temperature and pressure, and the need for high temperature bearings and seals.

  17. Double-ended ceramic helical-rotor expander

    DOEpatents

    Mohr, P.B.; Myers, W.B.

    1995-02-28

    A ceramic helical rotor expander is disclosed using a double-ended or tandem herringbone type rotor arrangement with bearing and seal assemblies remote from the hot gas inlets and especially capable of operating at an inlet temperature of above 1,100 C. The rotors are solid or hollow and bonded to hollow metal shafts, and mounted in a composite or simple prismatic casing. The rotors, casing and shafts are constructed from low expansivity materials. In the preferred embodiment the rotors are constructed of silicon nitride and the shafts constructed of an molybdenum alloy, with the metal shafts being supported in bearings and secured to synchronizing gears. The rotors and casing may be provided with coolant channels therein, and are constructed to eliminate the problem of end leakages at inlet temperature and pressure, and the need for high temperature bearings and seals. 3 figs.

  18. Pilot study of a novel, large-bore, fully covered self-expandable metallic stent for unresectable distal biliary malignancies.

    PubMed

    Mukai, Tsuyoshi; Yasuda, Ichiro; Isayama, Hiroyuki; Iwashita, Takuji; Itoi, Takao; Kawakami, Hiroshi; Kogure, Hirofumi; Nakai, Yousuke

    2016-09-01

    In patients with unresectable malignant distal biliary obstruction, covered self-expandable metallic stents (CSEMS) may remain patent longer than uncovered self-expandable metallic stents as a result of tumor ingrowth prevention. One main cause of recurrent biliary obstruction (RBO) in CSEMS is sludge formation, which can be prevented using a large-bore stent. Therefore, we developed a novel, 12-mm diameter fully covered SEMS (FCSEMS) and investigated its clinical safety, efficacy, and rate of adverse events. This prospective, multicenter pilot study, which ran between June 2011 and November 2012, included 38 consecutive patients with unresectable malignant distal biliary obstruction. All patients underwent endoscopic insertion of our novel stent. Primary endpoint was non-RBO rate 6 months after placement. Technical and functional success rates of the procedures were 100%. Six-month non-RBO rate was 50%, and median time to RBO was 184 days. Median survival time was 241 days. Twelve patients died within 6 months after stent placement without RBO. RBO was observed in 10 patients (26%), with seven experiencing stent occlusion and three experiencing stent migration. Adverse events other than RBO (at <30 days) developed in six patients (16%; cholecystitis, one; pancreatitis, one; hyperamylasemia, one; pancreatic ductitis, one; abdominal pain, two). Stent removal for reintervention was successfully completed in eight patients. Our novel FCSEMS may be safe and effective for managing malignant distal obstruction with an acceptable incidence of adverse events. © 2016 Japan Gastroenterological Endoscopy Society.

  19. Outcomes of secondary self-expandable metal stents versus surgery after delayed initial palliative stent failure in malignant colorectal obstruction.

    PubMed

    Yoon, Jin Young; Park, Soo Jung; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee

    2013-01-01

    When re-intervention is required due to an occluded first colorectal self-expanding metal stent for malignant colorectal obstruction, serious controversies exist regarding whether to use endoscopic re-stenting or surgery. To compare the clinical outcomes in patients who underwent stent re-insertion versus palliative surgery as a second intervention. A total of 115 patients who received either self-expandable metal stent (SEMS) insertion or palliative surgery for treatment of a second occurrence of malignant colorectal obstruction after the first SEMS placement were retrospectively studied between July 2005 and December 2009. The median overall survival (8.2 vs. 15.5 months) and progression-free survival (4.0 vs. 2.7 months) were not significantly different between the stent and surgery groups (p = 0.895 and 0.650, respectively). The median lumen patency in the stent group was 3.4 months and that in the surgery group was 7.9 months (p = 0.003). The immediate complication rate after second stent insertion was 13.9% and late complication rate was observed in 12 of 79 (15.2%) patients. There was no mortality related to the SEMS procedure. The complication and mortality rates associated with palliative surgery were 3.5% (2/57) and 12.3% (7/57), respectively. Although there is no significant difference in the overall survival between stenting and surgery, a secondary stent insertion had a lower mortality rate despite a shorter duration of temporary colorectal decompression compared to that of palliative surgery.

  20. Healthcare professionals' and parents' experiences of the confirmatory testing period: a qualitative study of the UK expanded newborn screening pilot.

    PubMed

    Moody, Louise; Atkinson, Lou; Kehal, Isher; Bonham, James R

    2017-05-08

    With further expansion of the number of conditions for which newborn screening can be undertaken, it is timely to consider the impact of positive screening results and the confirmatory testing period on the families involved. This study was undertaken as part of a larger programme of work to evaluate the Expanded Newborn Screening (ENBS) programme in the United Kingdom (UK). It was aimed to determine the views and experiences of healthcare professionals (HCPs) and parents on communication and interaction during the period of confirmatory testing following a positive screening result. Semi-structured interviews were undertaken with parents of children who had received a positive ENBS result and HCPs who had been involved with the diagnosis and support of parents. Ten parents and 11 healthcare professionals took part in the in-depth interviews. Questions considered the journey from the positive screening result through confirmatory testing to a confirmed diagnosis and the communication and interaction between the parents and HCPs that they had been experienced. Key themes were identified through thematic analysis. The results point to a number of elements within the path through confirmatory testing that are difficult for parents and could be further developed to improve the experience. These include the way in which the results are communicated to parents, rapid turnaround of results, offering a consistent approach, exploring interventions to support family relationships and reviewing the workload and scheduling implications for healthcare professionals. As technology enables newborn screening of a larger number of conditions, there is an increasing need to consider and mediate the potentially negative effects on families. The findings from this study point to a number of elements within the path through confirmatory testing that are difficult for parents and could be further developed to benefit the family experience.

  1. Utility of bioassays (lettuce, red clover, red fescue, Microtox, MetSTICK, Hyalella, bait lamina) in ecological risk screening of acid metal (Zn) contaminated soil.

    PubMed

    Chapman, E Emily V; Hedrei Helmer, Stephanie; Dave, Göran; Murimboh, John D

    2012-06-01

    The objective of this study was to assess selected bioassays and ecological screening tools for their suitability in a weight of evidence risk screening process of acidic metal contaminated soil. Intact soil cores were used for the tests, which minimizes changes in pH and metal bioavailability that may result from homogenization and drying of the soil. Soil cores were spiked with ZnCl(2) or CaCl(2). Leachate collected from the soil cores was used to account for the exposure pathways through pore water and groundwater. Tests assessed included MetSTICK in soil cores and Microtox in soil leachate, lettuce (Lactuca sativa), red fescue (Festuca rubra) and red clover (Trifolium pratense) in the soil cores and lettuce and red clover in soil leachate, Hyallella azteca in soil leachate, and an ecological soil function test using Bait Lamina in soil cores. Microtox, H. azteca, lettuce and red fescue showed higher sensitivity to low pH than to Zn concentrations and are therefore not recommended as tests on intact acidic soil cores and soil leachate. The Bait Lamina test appeared sensitive to pH levels below 3.7 but should be investigated further as a screening tool in less acidic soils. Among the bioassays, the MetSTICK and the T. pratense bioassays in soil cores were the most sensitive to Zn, with the lowest nominal NOEC of 200 and 400mg Zn/kg d.w., respectively. These bioassays were also tolerant of low pH, which make them suitable for assessing hazards of metal contaminated acid soils. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Attempts to Manipulate the Decay Time of Radioactive Nuclei

    NASA Astrophysics Data System (ADS)

    Fallin, B.; Grabow, B.; Tornow, W.

    2008-04-01

    It has been known for 20 years that electron screening strongly changes nuclear reaction cross sections at sub-Coulomb charged-particle projectile energies. The screening energy can be increased considerably if the target atoms are implanted in a metallic host and cooled to low temperature (T˜10 K). The large screening in metals derives from the Debye plasma model applied to the quasi-free metallic electrons. If ``time reversed,'' this model implies that the lifetime of radioactive nuclei placed in a metallic host can be manipulated by orders of magnitude. For α and β^+ decay one expects a shorter half-life, while for β^- decay and EC, a longer half-life is expected. The results of prior experiments testing this theory are controversial; about half of the published data confirm an effect, while the other half observe no effect. We will report on our experimental studies using ^64Cu and ^65Zn nuclei produced at TUNL via the ^63Cu(d,p) and ^65Cu(p,n) reactions, respectively. For ^64Cu, we detected the 511 keV annihilation γ rays and for ^65Zn the 1115.5 keV γ rays using HPGe detectors. In both cases we did not observe a half-life change outside experimental uncertainties between measurements at room temperature and those with the samples cooled to T=12 K.

  3. 49 CFR Appendix A to Part 1511 - Aviation Security Infrastructure Fee

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... final acceptance testing. This includes such equipment as Metal Detection Devices, Hand Wands, X-ray... such equipment as Metal Detection Devices, Hand Wands, X-ray screening machines, Explosives Trace... as test objects and X-ray radiation surveys, electricity costs and maintenance contract costs...

  4. 33 CFR 110.230 - Puget Sound Area, Wash.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... radar reflector screens of metal of sufficient size to permit target indication on the radar screen of... permission from the Captain of the Port (COTP), or his authorized representative. Vessel Traffic Service... grant revocable permits for the continuous use of the same berth. For the Anacortes General Anchorages...

  5. [From the "screen" society to concern for future generations].

    PubMed

    Le Coz, Pierre

    2015-01-01

    The youth of today is evolving in an unprecedented sociocultural context marked by the rapid development of new virtual technologies. Young people are constantly looking at screens, big and small, tactile and digital, which have invaded their social sphere. Connected, logged on, overstimulated, the new generation lives surrounded by reactivity and electronic interactions. It is adults' responsibility to expand the range of their cultural and outdoor activities in order to avoid the risk of their capacity for personal expression wasting away.

  6. The accuracy and efficiency of electronic screening for recruitment into a clinical trial on COPD.

    PubMed

    Schmickl, Christopher N; Li, Man; Li, Guangxi; Wetzstein, Marnie M; Herasevich, Vitaly; Gajic, Ognjen; Benzo, Roberto P

    2011-10-01

    Participant recruitment is an important process in successful conduct of randomized controlled trials. To facilitate enrollment into a National Institutes of Health-sponsored clinical trial involving patients with chronic obstructive pulmonary disease (COPD), we developed and prospectively validated an automated electronic screening tool based on boolean free-text search of admission notes in electronic medical records. During a 2-week validation period, all patients admitted to prespecified general medical services were screened for eligibility by both the electronic screening tool and a COPD nurse. Group discussion was the gold standard for confirmation of true-positive results. Compared with the gold standard, electronic screening yielded 100% sensitivity, 92% specificity, 100% negative predictive value, and 72% positive predictive value. Compared with traditional manual screening, electronic screening demonstrated time-saving potential of 76%. Thus, the electronic screening tool accurately identifies potential study subjects and improves efficiency of patient accrual for a clinical trial on COPD. This method may be expanded into other institutional and clinical settings. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Validity of clinical color vision tests for air traffic control specialists.

    DOT National Transportation Integrated Search

    1992-10-01

    An experiment on the relationship between aeromedical color vision screening test performance and performance on color-dependent tasks of Air Traffic Control Specialists was replicated to expand the data base supporting the job-related validity of th...

  8. Toxico-Cheminformatics: New and Expanding Public Resources to Support Chemical Toxicity Assessments

    EPA Science Inventory

    High-throughput screening (HTS) technologies, along with efforts to improve public access to chemical toxicity information resources and to systematize older toxicity studies, have the potential to significantly improve information gathering efforts for chemical assessments and p...

  9. The effect of screening doors and windows on indoor density of Anopheles arabiensis in south-west Ethiopia: a randomized trial

    PubMed Central

    2013-01-01

    Background Screening of houses might have impact on density of indoor host-seeking Anopheles mosquitoes. A randomized trial of screening windows and doors with metal mesh, and closing openings on eves and walls by mud was conducted to assess if reduce indoor densities of biting mosquitoes. Methods Mosquitoes were collected in forty houses using Centers for Diseases Control and Prevention (CDC) light traps biweekly in March and April 2011. A randomization of houses into control and intervention groups was done based on the baseline data. Windows and doors of 20 houses were screened by metal mesh, and openings on the walls and eves closed by mud and the rest 20 houses were used as control group. Mosquitoes were collected biweekly in October and November 2011 from both control and intervention houses. A Generalized Estimating Equations (GEE) with a negative binomial error distribution was used to account for over dispersion of Anopheles arabiensis and culicine counts and repeated catches made in the same house. Results Screening doors and windows, and closing openings on eves and wall by mud reduced the overall indoor densities of An. arabiensis by 40%. The effect of screenings pronounced on unfed An. arabiensis by resulting 42% reduction in houses with interventions. The total costs for screening windows and doors, and to close openings on the eves and walls by mud was 7.34 USD per house. Conclusion Screening houses reduced indoor density of An. arabiensis, and it was cheap and can easily incorporated into malaria vector strategies by local communities, but improving doors and windows fitness for screening should be considered during house construction to increase the efficacy of screenings. PMID:24028542

  10. Hydrodynamic model of screen channel liquid acquisition devices for in-space cryogenic propellant management

    NASA Astrophysics Data System (ADS)

    Darr, Samuel Ryan

    Technologies that enable the storage and transfer of cryogenic propellants in space will be needed for the next generation vehicles that will carry humans to Mars. One of the candidate technologies is the screen channel liquid acquisition device (LAD), which uses a metal woven wire mesh to separate the liquid and vapor phases so that single-phase liquid propellant can be transferred in microgravity. The purpose of this work is to provide an accurate hydrodynamic model of the liquid flow through a screen channel LAD. Chapter 2 provides a derivation of the flow-through-screen (FTS) boundary condition. The final boundary condition more accurately represents the complex geometry of metal woven wire mesh than the current model used in the literature. The effect of thermal contraction on the screen geometry due to large temperature changes common in cryogenic systems is quantified in this chapter as well. Chapter 3 provides a two-dimensional (2-D) analytical solution of the velocity and pressure fields in a screen channel LAD. This solution, which accounts for non-uniform injection through the screen, is compared with the traditional 1-D model which assumes a constant, uniform injection velocity. Chapter 4 describes the setup and results of an experiment that measures both the velocity and pressure fields in a screen channel LAD in order to validate the 2-D model. Results show that the 2-D model performs best against the new data and historical data. With the improved FTS boundary condition and the 2-D model, the pressure drop of a screen channel LAD is described with excellent accuracy. The result of this work is a predictive tool that will instill confidence in the design of screen channel LADs for future in-space propulsion systems.

  11. The effect of screening doors and windows on indoor density of Anopheles arabiensis in south-west Ethiopia: a randomized trial.

    PubMed

    Massebo, Fekadu; Lindtjørn, Bernt

    2013-09-12

    Screening of houses might have impact on density of indoor host-seeking Anopheles mosquitoes. A randomized trial of screening windows and doors with metal mesh, and closing openings on eves and walls by mud was conducted to assess if reduce indoor densities of biting mosquitoes. Mosquitoes were collected in forty houses using Centers for Diseases Control and Prevention (CDC) light traps biweekly in March and April 2011. A randomization of houses into control and intervention groups was done based on the baseline data. Windows and doors of 20 houses were screened by metal mesh, and openings on the walls and eves closed by mud and the rest 20 houses were used as control group. Mosquitoes were collected biweekly in October and November 2011 from both control and intervention houses. A Generalized Estimating Equations (GEE) with a negative binomial error distribution was used to account for over dispersion of Anopheles arabiensis and culicine counts and repeated catches made in the same house. Screening doors and windows, and closing openings on eves and wall by mud reduced the overall indoor densities of An. arabiensis by 40%. The effect of screenings pronounced on unfed An. arabiensis by resulting 42% reduction in houses with interventions. The total costs for screening windows and doors, and to close openings on the eves and walls by mud was 7.34 USD per house. Screening houses reduced indoor density of An. arabiensis, and it was cheap and can easily incorporated into malaria vector strategies by local communities, but improving doors and windows fitness for screening should be considered during house construction to increase the efficacy of screenings.

  12. Diagnosing cystic fibrosis in newborn screening in Poland - 15 years of experience.

    PubMed

    Sands, Dorota; Zybert, Katarzyna; Mierzejewska, Ewa; Ołtarzewski, Mariusz

    2015-01-01

    Early diagnosis of cystic fibrosis (CF) made by the introduction of CF NBS (Cystic Fibrosis Newborn Screening) provides the opportunity to undertake preventive measures and provide treatment before the development of irreversible changes in the respiratory tract and other complications. CF NBS was conducted as a pilot programme in four Polish districts in the period 1999-2003. In 2006 CF NBS started again and was gradually extended across the country. The aim of this study was to show the evolution of the Polish CF NBS strategies and assess the diagnostic consequences of this programme. The study involved children diagnosed and treated only in the IMiD Centre. The strategy in Polish CF NBS was modified over time. Firstly, the model IRT/IRT and IRT/IRT/DNA with one mutation was implemented, which was followed by IRT/DNA with a gradually expanding number of CFTR mutations (tab. I). Newborns with positive results of CF NBS were called to the CF IMiD Centre, and sweat tests were performed. The children diagnosed and children with mutations in both alleles of the CFTR gene even if at least one of them had undefined pathogenicity) were taken under IMiD Centre care. Sensitivity, specificity and positive predictive values during subsequent stages of CF NBS were calculated (tab. III). During the 1999-2003 pilot study 444 063 newborns underwent CF NBS and in 74 cases CF was diagnosed. 582 693 newborns were screened from September 2006 to December 2011 in four regions and 100 children were diagnosed with CF. The frequencies of CF in the Polish population in both screening periods were 1:5767 and 1:5712 respectively. Firstly, the IRT/IRT model was implemented, but the number of newborns called to the CF Centre was high - the PPV was 7.6%. In the next step CF NBS DNA analysis was used. Here sensitivity and specificity were high - nearly 100%. In the following years the number of mutations detected was expanded (including 16 most common ones in the Polish population). Due to the panel changes, the number of calls declined and the PPV (predictive positive value) improved (to 26.1%) after the application of expanded genetic analysis. Expanding the panel of mutations resulted in an increased number of carriers and observational subjects. IRT/DNA strategy with expanded DNA analysis provides the opportunity for earlier CF diagnosis even in children with normal sweat test values. However, this model caused frequent carrier detection and inconclusive diagnosis in comparison to IRT/IRT or IRT/IRT/DNA with a limited number of mutations. Further research and changes in Polish CF NBS are needed to increase the PPV, while preserving high sensitivity and specificity..

  13. Detection of other inborn errors of metabolism in hyperphenylalaninemic babies picked up on narrow-spectrum screening programs.

    PubMed

    Unal, Ozlem; Oztürk-Hişmi, Burcu; Coşkun, Turgay; Tokatlı, Ayşegül; Dursun, Ali; Sivri, Hatice Serap

    2012-01-01

    In many countries, neonatal screening programs have been unable to expand and have been limited to a few diseases. We highlight herein the opportunity available for the early detection of some inborn errors of metabolism (IEMs) in those countries in which newborn screening programs are limited. All the newborns that are referred to us for hyperphenylalaninemia are examined physically and their blood samples are checked by both high-performance liquid chromatography (HPLC) for blood phenylalanine levels and by amino acid analyzer for the measurement of blood amino acid concentrations. Seven patients who had been referred to our unit for hyperphenylalaninemia were eventually diagnosed with another IEM. A careful physical examination of the babies sent for positive screening test result combined with the utilization of low expense screening techniques at the experienced referring centers might facilitate otherwise missed opportunities for the early detection of some IEMs.

  14. Preparation of transition metal nanoparticles and surfaces modified with (CO)polymers synthesized by RAFT

    DOEpatents

    McCormick, III., Charles L.; Lowe, Andrew B.; Sumerlin, Brent S.

    2006-11-21

    A new, facile, general one-phase method of generating thio-functionalized transition metal nanoparticles and surfaces modified by (co)polymers synthesized by the RAFT method is described. The method includes the stops of forming a (co)polymer in aqueous solution using the RAFT methodology, forming a colloidal transition metal precursor solution from an appropriate transition metal; adding the metal precursor solution or surface to the (co)polymer solution, adding a reducing agent into the solution to reduce the metal colloid in situ to produce the stabilized nanoparticles or surface, and isolating the stabilized nanoparticles or surface in a manner such that aggregation is minimized. The functionalized surfaces generated using these methods can further undergo planar surface modifications, such as functionalization with a variety of different chemical groups, expanding their utility and application.

  15. Preparation of transition metal nanoparticles and surfaces modified with (co)polymers synthesized by RAFT

    DOEpatents

    McCormick, III, Charles L.; Lowe, Andrew B [Hattiesburg, MS; Sumerlin, Brent S [Pittsburgh, PA

    2011-12-27

    A new, facile, general one-phase method of generating thiol-functionalized transition metal nanoparticles and surfaces modified by (co)polymers synthesized by the RAFT method is described. The method includes the steps of forming a (co)polymer in aqueous solution using the RAFT methodology, forming a colloidal transition metal precursor solution from an appropriate transition metal; adding the metal precursor solution or surface to the (co)polymer solution, adding a reducing agent into the solution to reduce the metal colloid in situ to produce the stabilized nanoparticles or surface, and isolating the stabilized nanoparticles or surface in a manner such that aggregation is minimized. The functionalized surfaces generated using these methods can further undergo planar surface modifications, such as functionalization with a variety of different chemical groups, expanding their utility and application.

  16. Pollutant Source Tracking (PST) Technical Guidance

    DTIC Science & Technology

    2011-12-01

    in the context of heavy metals (lead, copper), is considered to be a minor process contribution to the source fingerprint. 3.7 RAPID SCREENING...limits (summarized in Table 2) support the use of ICP-AES (ICP-OES) for heavy metal determination in soils , sediments, wastewater and other matrices...are included here. Isotopic ratios of stable isotopes of the metal of interest can be used for source identification and apportionment in complex

  17. Reduction of heavy metals in residues from the dismantling of waste electrical and electronic equipment before incineration.

    PubMed

    Long, Yu-Yang; Feng, Yi-Jian; Cai, Si-Shi; Hu, Li-Fang; Shen, Dong-Sheng

    2014-05-15

    Residues disposal from the dismantling of waste electrical and electronic equipment are challenging because of the large waste volumes, degradation-resistance, low density and high heavy metal content. Incineration is advantageous for treating these residues but high heavy metal contents may exist in incinerator input and output streams. We have developed and studied a specialized heavy metal reduction process, which includes sieving and washing for treating residues before incineration. The preferable screen aperture for sieving was found to be 2.36mm (8 meshes) in this study; using this screen aperture resulted in the removal of approximately 47.2% Cu, 65.9% Zn, 26.5% Pb, 55.4% Ni and 58.8% Cd from the residues. Subsequent washing further reduces the heavy metal content in the residues larger than 2.36mm, with preferable conditions being 400rpm rotation speed, 5min washing duration and liquid-to-solid ratio of 25:1. The highest cumulative removal efficiencies of Cu, Zn, Pb, Ni and Cd after sieving and washing reached 81.1%, 61.4%, 75.8%, 97.2% and 72.7%, respectively. The combined sieving and washing process is environmentally friendly, can be used for the removal of heavy metals from the residues and has benefits in terms of heavy metal recycling. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Design Principles for Metal Oxide Redox Materials for Solar-Driven Isothermal Fuel Production.

    PubMed

    Michalsky, Ronald; Botu, Venkatesh; Hargus, Cory M; Peterson, Andrew A; Steinfeld, Aldo

    2015-04-01

    The performance of metal oxides as redox materials is limited by their oxygen conductivity and thermochemical stability. Predicting these properties from the electronic structure can support the screening of advanced metal oxides and accelerate their development for clean energy applications. Specifically, reducible metal oxide catalysts and potential redox materials for the solar-thermochemical splitting of CO 2 and H 2 O via an isothermal redox cycle are examined. A volcano-type correlation is developed from available experimental data and density functional theory. It is found that the energy of the oxygen-vacancy formation at the most stable surfaces of TiO 2 , Ti 2 O 3 , Cu 2 O, ZnO, ZrO 2 , MoO 3 , Ag 2 O, CeO 2 , yttria-stabilized zirconia, and three perovskites scales with the Gibbs free energy of formation of the bulk oxides. Analogously, the experimental oxygen self-diffusion constants correlate with the transition-state energy of oxygen conduction. A simple descriptor is derived for rapid screening of oxygen-diffusion trends across a large set of metal oxide compositions. These general trends are rationalized with the electronic charge localized at the lattice oxygen and can be utilized to predict the surface activity, the free energy of complex bulk metal oxides, and their oxygen conductivity.

  19. Regenerable metallic oxide systems for removal of carbon dioxide: A concept

    NASA Technical Reports Server (NTRS)

    Sutton, J. G.; Heimlich, P. F.; Tepper, E. H.

    1972-01-01

    Design concepts for portable canisters for removal of carbon dioxide are described. One is screen pack configuration consisting of brazed rectangular canister with four metal oxide packs inserted. Other is radial flow canister with perforated central tube. Methods of production and operating principles are presented.

  20. 40 CFR 266.106 - Standards to control metals emissions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... HAZARDOUS WASTE MANAGEMENT FACILITIES Hazardous Waste Burned in Boilers and Industrial Furnaces § 266.106... implemented by limiting feed rates of the individual metals to levels during the trial burn (for new... screening limit for the worst-case stack. (d) Tier III and Adjusted Tier I site-specific risk assessment...

  1. 40 CFR 266.106 - Standards to control metals emissions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... HAZARDOUS WASTE MANAGEMENT FACILITIES Hazardous Waste Burned in Boilers and Industrial Furnaces § 266.106... implemented by limiting feed rates of the individual metals to levels during the trial burn (for new... screening limit for the worst-case stack. (d) Tier III and Adjusted Tier I site-specific risk assessment...

  2. Resistivity of liquid metals on Veljkovic-Slavic pseudopotential

    NASA Astrophysics Data System (ADS)

    Abdel-Azez, Khalef

    1996-04-01

    An empirical form of screened model pseudopotential, proposed by Veljkovic and Slavic, is exploited for the calculation of resistivity of seven liquid metals through the correct re- determination of its parameters. The model derives qualitative support from the close agreement obtained between the computed results and the experiment.

  3. Expanding the molecular-ruler process through vapor deposition of hexadecanethiol

    PubMed Central

    Patron, Alexandra M; Hooker, Timothy S; Santavicca, Daniel F

    2017-01-01

    The development of methods to produce nanoscale features with tailored chemical functionalities is fundamental for applications such as nanoelectronics and sensor fabrication. The molecular-ruler process shows great utility for this purpose as it combines top-down lithography for the creation of complex architectures over large areas in conjunction with molecular self-assembly, which enables precise control over the physical and chemical properties of small local features. The molecular-ruler process, which most commonly uses mercaptoalkanoic acids and metal ions to generate metal-ligated multilayers, can be employed to produce registered nanogaps between metal features. Expansion of this methodology to include molecules with other chemical functionalities could greatly expand the overall versatility, and thus the utility, of this process. Herein, we explore the use of alkanethiol molecules as the terminating layer of metal-ligated multilayers. During this study, it was discovered that the solution deposition of alkanethiol molecules resulted in low overall surface coverage with features that varied in height. Because features with varied heights are not conducive to the production of uniform nanogaps via the molecular-ruler process, the vapor-phase deposition of alkanethiol molecules was explored. Unlike the solution-phase deposition, alkanethiol islands produced by vapor-phase deposition exhibited markedly higher surface coverages of uniform heights. To illustrate the applicability of this method, metal-ligated multilayers, both with and without an alkanethiol capping layer, were utilized to create nanogaps between Au features using the molecular-ruler process. PMID:29181290

  4. A pseudopotential approach to the superconducting state properties of metallic glass ?

    NASA Astrophysics Data System (ADS)

    Sharma, Ritu; Sharma, K. S.

    1997-08-01

    The superconducting state properties of the metallic glass 0953-2048/10/8/005/img2 have been investigated in the BCS - Eliashberg - McMillan framework by extending this theory to the binary metal glasses. Pseudo ions with average properties have been considered to replace both types of ions in the system. Values of the superconducting state parameters, namely electron - phonon coupling strength 0953-2048/10/8/005/img3, Coloumb pseudopotential 0953-2048/10/8/005/img4, transition temperature 0953-2048/10/8/005/img5, isotope effect exponent 0953-2048/10/8/005/img6 and interaction strength 0953-2048/10/8/005/img7 have been worked out using Ashcroft's potential and the linear potential due to Sharma and Kachhava along with six different forms of dielectric screening. The form factors directly obtained from the screened pseudopotential of Veljkovic and Slavic have also been used to explicitly observe the effect of the dielectric screening on 0953-2048/10/8/005/img8 and 0953-2048/10/8/005/img9 through 0953-2048/10/8/005/img10. The results obtained established the presence of a superconducting phase in 0953-2048/10/8/005/img2 glass.

  5. An economic evaluation of a genetic screening program for Tay-Sachs disease.

    PubMed Central

    Nelson, W B; Swint, J M; Caskey, C T

    1978-01-01

    The resolution of policy questions relating to medical genetic screening programs will not be without considerable difficulty. Examples include such issues as the optimal degree of screening program expansion, the relative values of screening for different genetic diseases, the appropriate sources of program funding (public vs. private), and the relative value of funding expanded genetic screening programs vs. research directed toward elimination of genetic traits themselves. Information on the net impact of the relevant alternatives is greatly needed, and this need will increase if the National Genetics Act receives funding approval. We have provided what is hopefully a contribution toward this end. While our analysis pertains to a specific disease and a specific screening program for that disease, the methodology is readily generalizable to other genetic diseases, as well as programs of any size or structure. Hopefully, this will serve to stimulate further research efforts that we believe are needed for the objective consideration of resource allocation alternatives. PMID:418675

  6. An economic evaluation of a genetic screening program for Tay-Sachs disease.

    PubMed

    Nelson, W B; Swint, J M; Caskey, C T

    1978-03-01

    The resolution of policy questions relating to medical genetic screening programs will not be without considerable difficulty. Examples include such issues as the optimal degree of screening program expansion, the relative values of screening for different genetic diseases, the appropriate sources of program funding (public vs. private), and the relative value of funding expanded genetic screening programs vs. research directed toward elimination of genetic traits themselves. Information on the net impact of the relevant alternatives is greatly needed, and this need will increase if the National Genetics Act receives funding approval. We have provided what is hopefully a contribution toward this end. While our analysis pertains to a specific disease and a specific screening program for that disease, the methodology is readily generalizable to other genetic diseases, as well as programs of any size or structure. Hopefully, this will serve to stimulate further research efforts that we believe are needed for the objective consideration of resource allocation alternatives.

  7. In silico strategies for the selection of chelating compounds with potential application in metal-promoted neurodegenerative diseases

    NASA Astrophysics Data System (ADS)

    Rodríguez-Rodríguez, Cristina; Rimola, Albert; Alí-Torres, Jorge; Sodupe, Mariona; González-Duarte, Pilar

    2011-01-01

    The development of new strategies to find commercial molecules with promising biochemical features is a main target in the field of biomedicine chemistry. In this work we present an in silico-based protocol that allows identifying commercial compounds with suitable metal coordinating and pharmacokinetic properties to act as metal-ion chelators in metal-promoted neurodegenerative diseases (MpND). Selection of the chelating ligands is done by combining quantum chemical calculations with the search of commercial compounds on different databases via virtual screening. Starting from different designed molecular frameworks, which mainly constitute the binding site, the virtual screening on databases facilitates the identification of different commercial molecules that enclose such scaffolds and, by imposing a set of chemical and pharmacokinetic filters, obey some drug-like requirements mandatory to deal with MpND. The quantum mechanical calculations are useful to gauge the chelating properties of the selected candidate molecules by determining the structure of metal complexes and evaluating their stability constants. With the proposed strategy, commercial compounds containing N and S donor atoms in the binding sites and capable to cross the BBB have been identified and their chelating properties analyzed.

  8. Fast elemental screening of soil and sediment profiles using small-spot energy-dispersive X-ray fluorescence: application to mining sediments geochemistry.

    PubMed

    Gonzalez-Fernandez, Oscar; Queralt, Ignacio

    2010-09-01

    Elemental analysis of different sediment cores originating from the Cartagena-La Union mining district in Spain was carried out by means of a programmable small-spot energy-dispersive X-ray fluorescence (EDXRF) spectrometer to study the distribution of heavy metals along soil profiles. Cores were obtained from upstream sediments of a mining creek, from the lowland sedimentation plain, and from a mining landfill dump (tailings pile). A programmable two-dimensional (2D) stage and a focal spot resolution of 600 μm allow us to obtain complete core mapping. Geochemical results were verified using a more powerful wavelength-dispersion X-ray fluorescence (WDXRF) technique. The data obtained was processed in order to study the statistical correlations within the elemental compositions. The results obtained allow us to observe the differential in-depth distribution of heavy metals among the sampled zones. Dump site cores exhibit a homogeneous distribution of heavy metals, whereas the alluvial plain core shows accumulation of heavy metals in the upper part. This approach can be useful for the fast screening of heavy metals in depositional environments around mining sites.

  9. Stents for colorectal obstruction: Past, present, and future

    PubMed Central

    Kim, Eui Joo; Kim, Yoon Jae

    2016-01-01

    Since the development of uncovered self-expanding metal stents (SEMS) in the 1990s, endoscopic stents have evolved dramatically. Application of new materials and new designs has expanded the indications for enteral SEMS. At present, enteral stents are considered the first-line modality for palliative care, and numerous types of enteral stents are under development for extended clinical usage, beyond a merely palliative purpose. Herein, we will discuss the current status and the future development of lower enteral stents. PMID:26811630

  10. Is my bottom-up uncertainty estimation on metal measurement adequate?

    NASA Astrophysics Data System (ADS)

    Marques, J. R.; Faustino, M. G.; Monteiro, L. R.; Ulrich, J. C.; Pires, M. A. F.; Cotrim, M. E. B.

    2018-03-01

    Is the estimated uncertainty under GUM recommendation associated with metal measurement adequately estimated? How to evaluate if the measurement uncertainty really covers all uncertainty that is associated with the analytical procedure? Considering that, many laboratories frequently underestimate or less frequently overestimate uncertainties on its results; this paper presents the evaluation of estimated uncertainties on two ICP-OES procedures of seven metal measurements according to GUM approach. Horwitz function and proficiency tests scaled standard uncertainties were used in this evaluation. Our data shows that most elements expanded uncertainties were from two to four times underestimated. Possible causes and corrections are discussed herein.

  11. Solid-binding peptides: smart tools for nanobiotechnology.

    PubMed

    Care, Andrew; Bergquist, Peter L; Sunna, Anwar

    2015-05-01

    Over the past decade, solid-binding peptides (SBPs) have been used increasingly as molecular building blocks in nanobiotechnology. These peptides show selectivity and bind with high affinity to the surfaces of a diverse range of solid materials including metals, metal oxides, metal compounds, magnetic materials, semiconductors, carbon materials, polymers, and minerals. They can direct the assembly and functionalisation of materials, and have the ability to mediate the synthesis and construction of nanoparticles and complex nanostructures. As the availability of newly synthesised nanomaterials expands rapidly, so too do the potential applications for SBPs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. First Experience of Inserting a Metallic Mesh Stent (Uventa Stent) in Malignant Ureteral Obstruction in Iran.

    PubMed

    Ghaed, Mohammad Ali; Daniali, Maziar; Ebrahimian, Mohammad

    2018-05-03

    Malignant ureteral obstruction is usually caused by an extrinsic compression including intra-abdominal cancers. One of the treatment modalities decompressing the obstruction is applying stent to open the ureter. Metallic Stent is an effective instrument which we used for the first time in Iran in our patient who had a metastatic colon cancerwith a single kidney and we used a Novel, Double-Layered, Coated, Self-expandable Metallic Mesh Stent (Uventa Stent) to keep the ureter open. After six months of follow up with ureteroscopy, there was no obstruction any more.

  13. Mineral resource of the month: molybdenum

    USGS Publications Warehouse

    Magyar, Michael J.

    2004-01-01

    Molybdenum is a metallic element that is most frequently used in alloy and stainless steels, which together represent the single largest market for molybdenum. Molybdenum has also proven invaluable in carbon steel, cast iron and superalloys. Its alloying versatility is unmatched because its addition enhances material performance under high-stress conditions in expanded temperature ranges and in highly corrosive environments. The metal is also used in catalysts, other chemicals, lubricants and many other applications.

  14. ToxCast Data Expands Universe of Chemical-Gene Interactions (SOT)

    EPA Science Inventory

    Characterizing the effects of chemicals in biological systems is often summarized by chemical-gene interactions, which have sparse coverage in literature. The ToxCast chemical screening program has produced bioactivity data for nearly 2000 chemicals and over 450 gene targets. Thi...

  15. Border and Transportation Security: Overview of Congressional Issues

    DTIC Science & Technology

    2004-12-17

    railways, airways, and waterways. While in the immediate aftermath of 9/11 efforts primarily concentrated on an expanded federal role in aviation ... security (in particular on the heightened screening of passengers and baggage), increasingly attention is being turned towards other modes of transportation.

  16. Airport metal detector activation is rare after posterior spinal fusion in children with scoliosis.

    PubMed

    Fabricant, Peter D; Robles, Alex; Blanco, John S

    2013-12-01

    Since the September 11, 2001 terrorist attacks on the World Trade Center in New York City, travel security has become an ever-increasing priority in the United States. Frequent parent and patient inquiry and recent literature reports have generated interest in the impact of heightened security measures on patients with orthopaedic implants, and have indicated increasing rates of metal detector triggering. There are no reports to date, however, evaluating children and adolescents who have undergone posterior spinal fusion for scoliosis, so responses to patient and parent inquiries are not data-driven. The purpose of this study is to determine the frequency of airport metal detector triggering by patients who have had posterior-only spinal fusion and to characterise any potential predictors of metal detector activation. A cross-sectional study was performed by interviewing 90 patients who underwent posterior-only spinal fusion for a diagnosis of juvenile or adolescent idiopathic scoliosis and have travelled by air in the past year. Demographic, clinical and surgical instrumentation data were collected and evaluated, along with patients' reports of airport metal detector triggering and subsequent screening procedures. Five patients with stainless steel instrumentation (5.6 % of the cohort) triggered an airport walkthrough metal detector, and an additional five patients who did not trigger an airport detector triggered a handheld detector at a different venue. All patients who triggered an airport metal detector had stainless steel instrumentation implanted prior to 2008, and no patient with titanium instrumentation triggered any detector in any venue. All trigger events required subsequent screening procedures, even when an implant card was presented. In this cohort of children and adolescents with posterior spinal instrumentation, airport walkthrough metal detector triggering was a rare event. Therefore, we advise patients and families with planned posterior scoliosis fusions using titanium instrumentation that airport detection risk is essentially non-existent, and only rare for those with planned stainless steel instrumentation. We no longer issue implant cards postoperatively, as these did not prevent further screening procedures in this cohort. Prognostic level 2. cross-sectional.

  17. Heptadecanoylcarnitine (C17) a novel candidate biomarker for propionic and methylmalonic acidemias during expanded newborn screening

    PubMed Central

    Malvagia, Sabrina; Haynes, Christopher A.; Grisotto, Laura; Ombrone, Daniela; Funghini, Silvia; Moretti, Elisa; McGreevy, Kathleen; Buggeri, Annibale; Guerrini, Renzo; Yahyaoui, Raquel; Garg, Uttam; Seeterlin, Mary; Chace, Donald; De Jesus, Victor; la Marca, Giancarlo

    2017-01-01

    Background 3-hydroxypalmitoleoyl-carnitine (C16:1-OH) was recently reported to be elevated in acylcarnitine profile of propionic acidemia (PA) or methylmalonic acidemia (MMA) patients during expanded newborn screening (NBS). High levels of C16:1-OH, combined with other hydroxylated long chain acylcarnitines are related to long-chain 3-hydroxyacyl-CoA dehydrogenase deficiency (LCHADD). Methods The acylcarnitine profile of two LCHADD patients was evaluated using liquid chromatography-tandem mass spectrometric method. A specific retention time was reported for each hydroxylated long chain acylcarnitine. The same method was applied to some neonatal dried blood spots (DBS) from PA and MMA patients presenting abnormal C16:1-OH concentrations. Results The final retention time of the peak corresponding to C16:1-OH in LCHADD patients differed from those in MMA and PA patients. Heptadecanoylcarnitine (C17) has been identified as the novel biomarker specific for PA and MMA patients through high resolution mass spectrometry (Orbitrap) experiments. We found that 21 out of 23 neonates (22 MMA, and 1PA) diagnosed through the Tuscany region NBS program had significantly higher levels of C17 compared to levels detected in controls. Twenty-three maternal deficiencies (21 vitamin B12 deficiency, 1 homocystinuria and 1 gastrin deficiency) and 82 false positive for propionylcarnitine (C3) results were also analyzed. Conclusions This paper reports on the characterization of a novel biomarker able to detect propionate disorders during expanded newborn screening (NBS). The use of this new biomarker may improve the analytical performances of NBS programs especially in laboratories where second tier tests are not performed. PMID:26368264

  18. Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks.

    PubMed

    van Boeckel, Petra G A; Dua, Kulwinder S; Weusten, Bas L A M; Schmits, Ruben J H; Surapaneni, Naveen; Timmer, Robin; Vleggaar, Frank P; Siersema, Peter D

    2012-02-29

    Benign esophageal ruptures and anastomotic leaks are life-threatening conditions that are often treated surgically. Recently, placement of partially and fully covered metal or plastic stents has emerged as a minimally invasive treatment option. We aimed to determine the clinical effectiveness of covered stent placement for the treatment of esophageal ruptures and anastomotic leaks with special emphasis on different stent designs. Consecutive patients who underwent placement of a fully covered self-expandable metal stent (FSEMS), a partially covered SEMS (PSEMS) or a self-expanding plastic stent (SEPS) for a benign esophageal rupture or anastomotic leak after upper gastrointestinal surgery in the period 2007-2010 were included. Data on patient demographics, type of lesion, stent placement and removal, clinical success and complications were collected A total of 52 patients received 83 esophageal stents (61 PSEMS, 15 FSEMS, 7 SEPS) for an anastomotic leak (n=32), iatrogenic rupture (n=13), Boerhaave's syndrome (n=4) or other cause (n=3). Endoscopic stent removal was successful in all but eight patients treated with a PSEMS due to tissue ingrowth. Clinical success was achieved in 34 (76%, intention-to-treat: 65%) patients (PSEMS: 73%, FSEMS: 83%, SEPS: 83%) after a median of 1 (range 1-5) stent and a median stenting time of 39 (range 7-120) days. In total, 33 complications in 24 (46%) patients occurred (tissue in- or overgrowth (n=8), stent migration (n=10), ruptured stent cover (all Ultraflex; n=6), food obstruction (n=3), severe pain (n=2), esophageal rupture (n=2), hemorrhage (n=2)). One (2%) patient died of a stent-related cause. Covered stents placed for a period of 5-6 weeks may well be an alternative to surgery for treating benign esophageal ruptures or anastomotic leaks. As efficacy between PSEMS, FSEMS and SEPS is not different, stent choice should depend on expected risks of stent migration (SEPS and FSEMS) and tissue in- or overgrowth (PSEMS).

  19. Intelligent detection of cracks in metallic surfaces using a waveguide sensor loaded with metamaterial elements.

    PubMed

    Ali, Abdulbaset; Hu, Bing; Ramahi, Omar

    2015-05-15

    This work presents a real life experiment of implementing an artificial intelligence model for detecting sub-millimeter cracks in metallic surfaces on a dataset obtained from a waveguide sensor loaded with metamaterial elements. Crack detection using microwave sensors is typically based on human observation of change in the sensor's signal (pattern) depicted on a high-resolution screen of the test equipment. However, as demonstrated in this work, implementing artificial intelligence to classify cracked from non-cracked surfaces has appreciable impact in terms of sensing sensitivity, cost, and automation. Furthermore, applying artificial intelligence for post-processing data collected from microwave sensors is a cornerstone for handheld test equipment that can outperform rack equipment with large screens and sophisticated plotting features. The proposed method was tested on a metallic plate with different cracks and the obtained experimental results showed good crack classification accuracy rates.

  20. Excitation of propagating magnetization waves by microstrip antennas

    NASA Astrophysics Data System (ADS)

    Dmitriev, V. F.; Kalinikos, B. A.

    1988-11-01

    We discuss the self-consistent theory of excitation of dipole-exchange magnetization waves by microstrip antennas in a metal-dielectric-ferrite-dielectric-metal stratified structure, magnetized under an arbitrary angle to the surface. Spin-wave Green's functions are derived, describing the response of the spin-system to a spatially inhomogeneous varying magnetic field. The radiative resistance of microstrip antenna is calculated. In this case the distribution of surface current density in the antenna is found on the basis of the analytic solution of a singular integral equation. The nature of the effect of metallic screens and redistributed surface current densities in the antenna on the frequency dependence of the resistive radiation is investigated. Approximate relations are obtained, convenient for practical calculations of radiative resistance of microstrip antennas both in a free and in a screened ferromagnetic film. The theoretical calculations are verified by data of experiments carried out on monocrystalline films of iron-yttrium garnet.

  1. Screening system and method of using same

    DOEpatents

    Jones, David A; Gresham, Christopher A; Basiliere, Marc L; Spates, James J; Rodacy, Philip J

    2014-04-15

    An integrated apparatus and method for screening an object for a target material is provided. The integrated apparatus comprises a housing and an integrated screener. The housing is positionable adjacent the object, and has a channel therethrough. The integrated screener is positionable in the housing, and comprises a fan, at least one filter, a heater and an analyzer. The fan is for drawing air carrying particles and vapor through the channel of the housing. The filter(s) is/are positionable in the channel of the housing for passage of the air therethrough. The filter(s) comprise(s) at least one metal foam having a plurality of pores therein for collecting and adsorbing a sample from the particles and vapor passing therethrough. The heater is for applying heat to the at least one metal foam whereby the collected sample is desorbed from the metal foam. The analyzer detects the target material from the desorbed sample.

  2. Soft Coulomb gap and asymmetric scaling towards metal-insulator quantum criticality in multilayer MoS2.

    PubMed

    Moon, Byoung Hee; Bae, Jung Jun; Joo, Min-Kyu; Choi, Homin; Han, Gang Hee; Lim, Hanjo; Lee, Young Hee

    2018-05-24

    Quantum localization-delocalization of carriers are well described by either carrier-carrier interaction or disorder. When both effects come into play, however, a comprehensive understanding is not well established mainly due to complexity and sparse experimental data. Recently developed two-dimensional layered materials are ideal in describing such mesoscopic critical phenomena as they have both strong interactions and disorder. The transport in the insulating phase is well described by the soft Coulomb gap picture, which demonstrates the contribution of both interactions and disorder. Using this picture, we demonstrate the critical power law behavior of the localization length, supporting quantum criticality. We observe asymmetric critical exponents around the metal-insulator transition through temperature scaling analysis, which originates from poor screening in insulating regime and conversely strong screening in metallic regime due to free carriers. The effect of asymmetric scaling behavior is weakened in monolayer MoS 2 due to a dominating disorder.

  3. Intelligent Detection of Cracks in Metallic Surfaces Using a Waveguide Sensor Loaded with Metamaterial Elements

    PubMed Central

    Ali, Abdulbaset; Hu, Bing; Ramahi, Omar M.

    2015-01-01

    This work presents a real-life experiment implementing an artificial intelligence model for detecting sub-millimeter cracks in metallic surfaces on a dataset obtained from a waveguide sensor loaded with metamaterial elements. Crack detection using microwave sensors is typically based on human observation of change in the sensor's signal (pattern) depicted on a high-resolution screen of the test equipment. However, as demonstrated in this work, implementing artificial intelligence to classify cracked from non-cracked surfaces has appreciable impacts in terms of sensing sensitivity, cost, and automation. Furthermore, applying artificial intelligence for post-processing the data collected from microwave sensors is a cornerstone for handheld test equipment that can outperform rack equipment with large screens and sophisticated plotting features. The proposed method was tested on a metallic plate with different cracks, and the experimental results showed good crack classification accuracy rates. PMID:25988871

  4. Characterisation of an Exploding Foil Initiator (EFI) system

    NASA Astrophysics Data System (ADS)

    Davies, H. R.; Chapman, D. J.; Vine, T. A.; Proud, W. G.

    2009-06-01

    Exploding Foil Initiators (EFIs) provide a safe and reliable means of detonation of explosives. They are highly insensitive to mechanical shock and electrical interference, requiring a specific high current pulse for initiation. The use of only insensitive secondary explosives and not more sensitive primary explosives further improves safety. When a high current is passed through the metal bridge, a plasma is formed as the metal can not expand beyond the polymer film layer above. This causes the film to expand forming a bubble or shearing off to form a flyer. These flyers can then be used to initiate secondary explosives. Due to the very high speed at which these systems operate, high speed streak photography was used to characterise the behaviour of the polymer film flyers produced. This paper will report the preliminary findings on the mechanical, electrical and velocity changes seen in some proprietary systems.

  5. Biodegradable stents for the treatment of refractory or recurrent benign esophageal stenosis.

    PubMed

    Imaz-Iglesia, Iñaki; García-Pérez, Sonia; Nachtnebel, Anna; Martín-Águeda, Belén; Sánchez-Piedra, Carlos; Karadayi, Bilgehan; Demirbaş, Ali Rıza

    2016-06-01

    Esophageal stents are used for the treatment of refractory and recurrent dyphagias. In 2007, esophageal biodegradable stents (EBS) were authorised as an alternative to existing metal and plastic stents in Europe. The advantages claimed for EBS are fewer complications concerning tissue ingrowth, stent migration and stent removal. We performed a systematic review to evaluate the efficacy and safety of EBS compared to fully-covered self-expanding metal stents, self-expanding plastic stents, and esophageal dilation for the treatment of refractory or recurrent benign esophageal stenosis. Three comparative studies (one randomized controlled trial and two cohort studies) were assessed. The studies used different inclusion criteria, had a very small (sample) size and the quality of the evidence was very low. Expert commentary: The current evidence is insufficient to determine the relative efficacy or safety of esophageal biodegradable stents. The results of this systematic review should be updated once new evidence is available.

  6. Method of shielding a liquid-metal-cooled reactor

    DOEpatents

    Sayre, Robert K.

    1978-01-01

    The primary heat transport system of a nuclear reactor -- particularly for a liquid-metal-cooled fast-breeder reactor -- is shielded and protected from leakage by establishing and maintaining a bed of a powdered oxide closely and completely surrounding all components thereof by passing a gas upwardly therethrough at such a rate as to slightly expand the bed to the extent that the components of the system are able to expand without damage and yet the particles of the bed remain close enough so that the bed acts as a guard vessel for the system. Preferably the gas contains 1 to 10% oxygen and the gas is passed upwardly through the bed at such a rate that the lower portion of the bed is a fixed bed while the upper portion is a fluidized bed, the line of demarcation therebetween being high enough that the fixed bed portion of the bed serves as guard vessel for the system.

  7. Treatment of nostril and nasal stenosis due to facial burn using a self-expandable metallic esophageal stent.

    PubMed

    Sekine, Kuwon; Matsune, Shoji; Shiiba, Kyoko; Kimura, Maki; Okubo, Kimihiro; Kaneshiro, Tadashi; Tajima, Hiroyuki; Murakami, Masahiro; Kurokawa, Akira

    2015-08-01

    For the treatment of nasal and nostril stenosis caused by facial burn, it is necessary to perform rhinoplasty and nasal vestibuloplasty using various flaps, perform cicatrectomy of the nostrils with a rhinosurgical procedure, and prevent restenosis of the nostrils and nasal cavity for a certain period by methods such as placement of a nasal retainer or transnasal airway and gauze packing of the nasal cavity. With all methods, postoperative placement of a retainer or nasal treatment is necessary for the prevention of postoperative restenosis, and the patient's cooperation is essential. In a patient who did not cooperate in postoperative treatments due to autism and had recurrences of nasal and nostril stenosis after conventional surgical treatments, adequate patency of the nasal cavity and nostrils could be maintained with minimal postoperative treatment by placing a self-expandable metallic esophageal stent. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. A High-Throughput Assay for Screening of Natural Products that Enhanced Tumoricidal Activity of NK Cells.

    PubMed

    Gong, Chenyuan; Ni, Zhongya; Yao, Chao; Zhu, Xiaowen; Ni, Lulu; Wang, Lixin; Zhu, Shiguo

    2015-01-01

    Recently, immunotherapy has shown a lot of promise in cancer treatment and different immune cell types are involved in this endeavor. Among different immune cell populations, NK cells are also an important component in unleashing the therapeutic activity of immune cells. Therefore, in order to enhance the tumoricidal activity of NK cells, identification of new small-molecule natural products is important. Despite the availability of different screening methods for identification of natural products, a simple, economic and high-throughput method is lacking. Hence, in this study, we have developed a high-throughput assay for screening and indentifying natural products that can enhance NK cell-mediated killing of cancer cells. We expanded human NK cell population from human peripheral blood mononuclear cells (PBMCs) by culturing these PBMCs with membrane-bound IL-21 and CD137L engineered K562 cells. Next, expanded NK cells were co-cultured with non-small cell lung cancer (NSCLC) cells with or without natural products and after 24 h of co-culturing, harvested supernatants were analyzed for IFN-γ secretions by ELISA method. We screened 502 natural products and identified that 28 candidates has the potential to induce IFN-γ secretion by NK cells to varying degrees. Among the 28 natural product candidates, we further confirmed and analyzed the potential of one molecule, andrographolide. It actually increased IFN-γ secretion by NK cells and enhanced NK cell-mediated killing of NSCLC cells. Our results demonstrated that this IFN-γ based high-throughput assay for screening of natural products for NK cell tumoricidal activity is a simple, economic and reliable method.

  9. Numerical evaluation of moiré pattern in touch sensor module with electrode mesh structure in oblique view

    NASA Astrophysics Data System (ADS)

    Pournoury, M.; Zamiri, A.; Kim, T. Y.; Yurlov, V.; Oh, K.

    2016-03-01

    Capacitive touch sensor screen with the metal materials has recently become qualified for substitution of ITO; however several obstacles still have to be solved. One of the most important issues is moiré phenomenon. The visibility problem of the metal-mesh, in touch sensor module (TSM) is numerically considered in this paper. Based on human eye contract sensitivity function (CSF), moiré pattern of TSM electrode mesh structure is simulated with MATLAB software for 8 inch screen display in oblique view. Standard deviation of the generated moiré by the superposition of electrode mesh and screen image is calculated to find the optimal parameters which provide the minimum moiré visibility. To create the screen pixel array and mesh electrode, rectangular function is used. The filtered image, in frequency domain, is obtained by multiplication of Fourier transform of the finite mesh pattern (product of screen pixel and mesh electrode) with the calculated CSF function for three different observer distances (L=200, 300 and 400 mm). It is observed that the discrepancy between analytical and numerical results is less than 0.6% for 400 mm viewer distance. Moreover, in the case of oblique view due to considering the thickness of the finite film between mesh electrodes and screen, different points of minimum standard deviation of moiré pattern are predicted compared to normal view.

  10. Impacts of household income and economic recession on participation in colorectal cancer screening in Korea.

    PubMed

    Myong, Jun-Pyo; Kim, Hyoung-Ryoul

    2012-01-01

    To assess the impact of household income and economic recession on participation in CRC screening, we estimated annual participating proportions from 2007 to 2009 for different CRC screening modalities according to household income levels. A total of 8,042 subjects were derived from the fourth Korean National Health and Nutrition Examination Survey (KNHANES IV). Multivariate logistic regression analysis was used to estimate odds ratios and 95% confidence intervals for CRC screening with household income quartiles by gender in each year. People were less likely to attend a high-cost CRC screening such as a sigmoidoscopy or colonoscopy independent of the income quartile during the economic recession. Income disparities for participating in opportunistic cancer screening appear to have existed among both males and females during the three years (2007-2009), but were most distinctive in 2009. An increase in mortality of CRC can therefore be expected due to late detection in periods of economic crisis. Accordingly, the government should expand the coverage of CRC screening to prevent excess deaths by reducing related direct and indirect costs during the economic recession.

  11. Reverberatory screen for a radiant burner

    DOEpatents

    Gray, Paul E.

    1999-01-01

    The present invention relates to porous mat gas fired radiant burner panels utilizing improved reverberatory screens. The purpose of these screens is to boost the overall radiant output of the burner relative to a burner using no screen and the same fuel-air flow rates. In one embodiment, the reverberatory screen is fabricated from ceramic composite material, which can withstand higher operating temperatures than its metallic equivalent. In another embodiment the reverberatory screen is corrugated. The corrugations add stiffness which helps to resist creep and thermally induced distortions due to temperature or thermal expansion coefficient differences. As an added benefit, it has been unexpectedly discovered that the corrugations further increase the radiant efficiency of the burner. In a preferred embodiment, the reverberatory screen is both corrugated and made from ceramic composite material.

  12. Covered metal stent or multiple plastic stents for refractory pancreatic ductal strictures in chronic pancreatitis: a systematic review.

    PubMed

    Shen, Yonghua; Liu, Mingdong; Chen, Min; Li, Yunhong; Lu, Ying; Zou, Xiaoping

    2014-01-01

    Refractory chronic pancreatitis has been proposed as a challenge for endoscopists following routine single plastic stenting. However, data on the efficacy and safety of further endoscopic stenting are still controversial. The current systematic review aimed to assess the efficacy and safety of placement of fully covered self-expandable metal stent (FCSEMS) and multiple plastic stents. Databases including MEDLINE, EMBASE, the Cochrane Library, CBM, CNKI, VIP, and WANFANG Database were used to search relevant trials. Published studies were assessed by using well-defined inclusion and exclusion criteria. The process was independently performed by two investigators. A total of 5 studies provided data of 80 patients. Forest plots and publication bias were not carried out because few studies were relevant and screened studies were all case series. The technical success rate was 100% both in placement of FCSEMS and multiple plastic stents. The functional success rate after placement of FCSEMS was 100%, followed by multiple plastic stents (94.7%). Complications occurred 26.2% after FCSEMS placement, which was not described in detail in multiple plastic stents. The stent migration rate was 8.2% for FCSEMS and 10.5% for multiple plastic stents. Reintervention rate was 9.8% for FCSEMS and 15.8% for multiple plastic stents. Pain improvement rate was 85.2% for FCSEMS and 84.2% for multiple plastic stents. FCSEMS appeared to be no significant difference with multiple plastic stents in treatment of refractory chronic pancreatitis. We need to develop more investigations. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  13. Natural attenuation software (NAS): Assessing remedial strategies and estimating timeframes

    USGS Publications Warehouse

    Mendez, E.; Widdowson, M.; Chapelle, F.; Casey, C.

    2005-01-01

    Natural Attenuation Software (NAS) is a screening tool to estimate remediation timeframes for monitored natural attenuation (MNA) and to assist in decision-making on the level of source zone treatment in conjunction with MNA using site-specific remediation objectives. Natural attenuation processes that NAS models include are advection, dispersion, sorption, non-aqueous phase liquid (NAPL) dissolution, and biodegradation of either petroleum hydrocarbons or chlorinated ethylenes. Newly-implemented enhancements to NAS designed to maximize the utility of NAS for site managers were observed. NAS has expanded source contaminant specification options to include chlorinated ethanes and chlorinated methanes, and to allow for the analysis of any other user-defined contaminants that may be subject to microbially-mediated transformations (heavy metals, radioisotopes, etc.). Included is the capability to model co-mingled plumes, with constituents from multiple contaminant categories. To enable comparison of remediation timeframe estimates between MNA and specific engineered remedial actions , NAS was modified to incorporate an estimation technique for timeframes associated with pump-and-treat remediation technology for comparison to MNA. This is an abstract of a paper presented at the 8th International In Situ and On-Site Bioremediation Symposium (Baltimore, MD 6/6-9/2005).

  14. Assistive Technology and Adults with Learning Disabilities: A Blueprint for Exploration and Advancement.

    ERIC Educational Resources Information Center

    Raskind, Marshall

    1993-01-01

    This article describes assistive technologies for persons with learning disabilities, including word processing, spell checking, proofreading programs, outlining/"brainstorming" programs, abbreviation expanders, speech recognition, speech synthesis/screen review, optical character recognition systems, personal data managers, free-form databases,…

  15. Research on Internationalisation in Higher Education--Exploratory Analysis

    ERIC Educational Resources Information Center

    Yemini, Miri; Sagie, Netta

    2016-01-01

    Research on internationalisation in higher education has dramatically expanded over the last several decades. This study aims to provide an overview of the research developments undertaken between 1980 and 2014, on internationalisation in higher education. Explorative, systematic literature screening and analysis were undertaken, encompassing over…

  16. ENVIRONMENTAL IMMUNOCHEMISTRY AT THE U.S. EPA, NATIONAL EXPOSURE RESEARCH LABORATORY'S HUMAN EXPOSURE BRANCH

    EPA Science Inventory

    Immunoehemical methods are responding to the changing needs of regulatory and monitoring programs and are meeting new analytical challenges as they arise. Recent advances in environmental immunoehemistry have expanded the role of immunoassays from field screening methods to hig...

  17. Apicobasal domain identities of expanding tubular membranes depend on glycosphingolipid biosynthesis.

    PubMed

    Zhang, Hongjie; Abraham, Nessy; Khan, Liakot A; Hall, David H; Fleming, John T; Göbel, Verena

    2011-09-18

    Metazoan internal organs are assembled from polarized tubular epithelia that must set aside an apical membrane domain as a lumenal surface. In a global Caenorhabditis elegans tubulogenesis screen, interference with several distinct fatty-acid-biosynthetic enzymes transformed a contiguous central intestinal lumen into multiple ectopic lumens. We show that multiple-lumen formation is caused by apicobasal polarity conversion, and demonstrate that in situ modulation of lipid biosynthesis is sufficient to reversibly switch apical domain identities on growing membranes of single post-mitotic cells, shifting lumen positions. Follow-on targeted lipid-biosynthesis pathway screens and functional genetic assays were designed to identify a putative single causative lipid species. They demonstrate that fatty-acid biosynthesis affects polarity through sphingolipid synthesis, and reveal ceramide glucosyltransferases (CGTs) as end-point biosynthetic enzymes in this pathway. Our findings identify glycosphingolipids, CGT products and obligate membrane lipids, as critical determinants of in vivo polarity and indicate that they sort new components to the expanding apical membrane.

  18. Apicobasal domain identities of expanding tubular membranes depend on glycosphingolipid biosynthesis

    PubMed Central

    Zhang, Hongjie; Abraham, Nessy; Khan, Liakot A.; Hall, David H.; Fleming, John T.; Gobel, Verena

    2011-01-01

    Metazoan internal organs are assembled from polarized tubular epithelia that must set aside an apical membrane domain as a lumenal surface. In a global Caenorhabditis elegans tubulogenesis screen, interference with several distinct fatty-acid-biosynthetic enzymes transformed a contiguous central intestinal lumen into multiple ectopic lumens. We show that multiple-lumen formation is caused by apicobasal polarity conversion, and demonstrate that in situ modulation of lipid biosynthesis is sufficient to reversibly switch apical domain identities on growing membranes of single postmitotic cells, shifting lumen positions. Follow-on targeted lipid-biosynthesis pathway screens and functional genetic assays were designed to identify a putative single causative lipid species. They demonstrate that fatty-acid biosynthesis affects polarity via sphingolipid synthesis, and reveal ceramideglucosyltransferases (CGTs) as endpoint biosynthetic enzymes in this pathway. Our findings identify glycosphingolipids (GSLs), CGT products and obligate membrane lipids, as critical determinants of in vivo polarity and suggest they sort new components to the expanding apical membrane. PMID:21926990

  19. Cancer screening and health system resilience: keys to protecting and bolstering preventive services during a financial crisis.

    PubMed

    Martin-Moreno, Jose M; Anttila, Ahti; von Karsa, Lawrence; Alfonso-Sanchez, Jose L; Gorgojo, Lydia

    2012-09-01

    The aim of this paper is to elucidate the rationale for sustaining and expanding cost-effective, population-based screening services for breast, cervical and colorectal cancers in the context of the current financial crisis. Our objective is not only to promote optimal delivery of high-quality secondary cancer prevention services, but also to underline the importance of strengthening comprehensive cancer control, and with it, health system response to the complex care challenges posed by all chronic diseases. We focus primarily on issues surrounding planning, organisation, implementation and resources, arguing that given the growing cancer burden, policymakers have ample justification for establishing and expanding population-based programmes that are well-organised, well-resourced and well-executed. In a broader economic context of rescue packages, deficits and cutbacks to government entitlements, health professionals must intensify their advocacy for the protection of vital preventive health services by fighting for quality services with clear benefits for population health outcomes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. A predictive structural model for bulk metallic glasses

    PubMed Central

    Laws, K. J.; Miracle, D. B.; Ferry, M.

    2015-01-01

    Great progress has been made in understanding the atomic structure of metallic glasses, but there is still no clear connection between atomic structure and glass-forming ability. Here we give new insights into perhaps the most important question in the field of amorphous metals: how can glass-forming ability be predicted from atomic structure? We give a new approach to modelling metallic glass atomic structures by solving three long-standing problems: we discover a new family of structural defects that discourage glass formation; we impose efficient local packing around all atoms simultaneously; and we enforce structural self-consistency. Fewer than a dozen binary structures satisfy these constraints, but extra degrees of freedom in structures with three or more different atom sizes significantly expand the number of relatively stable, ‘bulk' metallic glasses. The present work gives a new approach towards achieving the long-sought goal of a predictive capability for bulk metallic glasses. PMID:26370667

  1. Structural basis for expanding the application of bioligand in metal bioremediation: A review.

    PubMed

    Sharma, Virbala; Pant, Deepak

    2018-03-01

    Bioligands (BL) present in plant and microbes are primarily responsible for their use in metal decontamination. Both primary (proteins and amino acid) and secondary (proliferated) response in the form of BL is possible in plants and microbes toward metal bioremediation. Structure of these BL have specific requirement for preferential binding towards a particular metal in biomass. The aim of this review is to explore various templates from BL (as metal host) for the metal detoxification/decontamination and associated bioremediation. Mechanistic explanation for bioremediation may involve the various processes like: (i) electron transfer; (ii) translocation; and (iii) coordination number variation. HSAB (hard and soft acid and base) concept can act as guiding principle for many such processes. It is possible to investigate various structural homolog of BL (similar to secondary response in living stage) for the possible improvement in bioremediation process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Systematic Review and Meta-study Synthesis of Qualitative Studies Evaluating Facilitators and Barriers to Participation in Colorectal Cancer Screening.

    PubMed

    Honein-AbouHaidar, Gladys N; Kastner, Monika; Vuong, Vincent; Perrier, Laure; Daly, Corinne; Rabeneck, Linda; Straus, Sharon; Baxter, Nancy N

    2016-06-01

    Screening reduces the incidence, morbidity, and mortality of colorectal cancer, yet participation tends to be low. We undertook a systematic review and meta-study synthesis of qualitative studies to identify facilitators and barriers to colorectal cancer screening participation. We searched major bibliographic databases for records published in all languages from inception to February 2015. Included primary studies that elicited views and perceptions towards colorectal cancer screening were appraised for relevance and quality. We used a two-stage synthesis to create an interpretation of colorectal cancer screening decisions grounded in primary studies; a thematic analysis to group themes and systematically compare studies and a meta-synthesis to generate an expanded theory of colorectal cancer screening participation. Ninety-four studies were included. The decision to participate in colorectal cancer screening depended on an individual's awareness of colorectal cancer screening. Awareness affected views of cancer, attitudes towards colorectal cancer screening modalities, and motivation for screening. Factors mediating awareness included public education to address misconceptions, primary care physician efforts to recommend screening, and the influence of friends and family. Specific barriers to participation in populations with lower participation rates included language barriers, logistical challenges to attending screening tests, and cultural beliefs. This study identifies key barriers, facilitators, and mediators to colorectal cancer screening participation. Cancer Epidemiol Biomarkers Prev; 25(6); 907-17. ©2016 AACR. ©2016 American Association for Cancer Research.

  3. Microstructure of a base metal thick film system. [Glass frit with base metal oxide addition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mentley, D.E.

    1976-06-01

    A base metal thick film conductor system using glass frits with base metal oxide additions was investigated as metallization for hybrid microcircuits. Application of previous work on wetting and chemical bonding was made to this system. The observation of changes in the properties of the thick film was made by photomicrographs of screened samples and sheet resistivity measurements. In addition to the chemical and wetting properties, the effect of glass frit particle size on conductivity was also analyzed. The base metal oxide addition was found to produce a more consistent thick film conductor at low volume percentages of metal bymore » inhibiting the formation of low melting redox reaction products.« less

  4. Remediation of AMD using natural and waste material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Basir, Nur Athirah Mohamad; Yaacob, Wan Zuhairi Wan

    2014-09-03

    Acid Mine Drainage (AMD) is highly acidic, sulphate rich and frequently carries a high transition metal and heavy metal burden. These AMD's eventually migrate into streams and rivers and impact negatively on the quality of these water bodies. So it is dire necessary to treat this AMD. Various materials such as ladle furnace slag (LFS), bentonite, zeolite, active carbon and kaolinite are currently available to remove heavy metals from contaminated water. All these materials are capable to rise up the pH value and adsorb heavy metals. The process is divided into two stages; screening test and tank experiment. Screening testmore » is conduct by using Batch Equilibrium Test (BET), X-Ray Fluorescene (XRF) identification also Scanning Electron Microscopic (SEM) characteristic. The results showed that all the concentration of heavy metal are decreasing extremely and pH value rise up except for kaolinite. From screening test only ladle furnace slag, bentonite, zeolite and active carbon are chosen for the tank experiment. Tank experiment design with 18cm (H) X 15cm (L) X 15cm (H) was made by silica glass. All these treatment materials were stirred in the tank for 30 days. Initial pH for all tanks is 2.4 and after 30 days is changing into 6.11, 3.91, 2.98 and 2.71 for LFS, bentonite, active carbon as well as zeolite respectively. LFS is the best material for absorption of Zn, Mn and Cu in the synthetic solution. Meanwhile, bentonite is the best absorbent for Ni, Fe and Cd. The conclusion shows that LFS might have big potentials to control AMD pollution base on neutralize pH resulting in a great improvement in the quality of the water.« less

  5. Remediation of AMD using natural and waste material

    NASA Astrophysics Data System (ADS)

    Basir, Nur Athirah Mohamad; Yaacob, Wan Zuhairi Wan

    2014-09-01

    Acid Mine Drainage (AMD) is highly acidic, sulphate rich and frequently carries a high transition metal and heavy metal burden. These AMD's eventually migrate into streams and rivers and impact negatively on the quality of these water bodies. So it is dire necessary to treat this AMD. Various materials such as ladle furnace slag (LFS), bentonite, zeolite, active carbon and kaolinite are currently available to remove heavy metals from contaminated water. All these materials are capable to rise up the pH value and adsorb heavy metals. The process is divided into two stages; screening test and tank experiment. Screening test is conduct by using Batch Equilibrium Test (BET), X-Ray Fluorescene (XRF) identification also Scanning Electron Microscopic (SEM) characteristic. The results showed that all the concentration of heavy metal are decreasing extremely and pH value rise up except for kaolinite. From screening test only ladle furnace slag, bentonite, zeolite and active carbon are chosen for the tank experiment. Tank experiment design with 18cm (H) X 15cm (L) X 15cm (H) was made by silica glass. All these treatment materials were stirred in the tank for 30 days. Initial pH for all tanks is 2.4 and after 30 days is changing into 6.11, 3.91, 2.98 and 2.71 for LFS, bentonite, active carbon as well as zeolite respectively. LFS is the best material for absorption of Zn, Mn and Cu in the synthetic solution. Meanwhile, bentonite is the best absorbent for Ni, Fe and Cd. The conclusion shows that LFS might have big potentials to control AMD pollution base on neutralize pH resulting in a great improvement in the quality of the water.

  6. Thermodynamic screening of metal-substituted MOFs for carbon capture.

    PubMed

    Koh, Hyun Seung; Rana, Malay Kumar; Hwang, Jinhyung; Siegel, Donald J

    2013-04-07

    Metal-organic frameworks (MOFs) have emerged as promising materials for carbon capture applications due to their high CO2 capacities and tunable properties. Amongst the many possible MOFs, metal-substituted compounds based on M-DOBDC and M-HKUST-1 have demonstrated amongst the highest CO2 capacities at the low pressures typical of flue gasses. Here we explore the possibility for additional performance tuning of these compounds by computationally screening 36 metal-substituted variants (M = Be, Mg, Ca, Sr, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Mo, W, Sn, and Pb) with respect to their CO2 adsorption enthalpy, ΔH(T=300K). Supercell calculations based on van der Waals density functional theory (vdW-DF) yield enthalpies in good agreement with experimental measurements, out-performing semi-empirical (DFT-D2) and conventional (LDA & GGA) functionals. Our screening identifies 13 compounds having ΔH values within the targeted thermodynamic window -40 ≤ ΔH ≤ -75 kJ mol(-1): 8 are based on M-DODBC (M = Mg, Ca, Sr, Sc, Ti, V, Mo, and W), and 5 on M-HKUST-1 (M = Be, Mg, Ca, Sr and Sc). Variations in the electronic structure and the geometry of the structural building unit are examined and used to rationalize trends in CO2 affinity. In particular, the partial charge on the coordinatively unsaturated metal sites is found to correlate with ΔH, suggesting that this property may be used as a simple performance descriptor. The ability to rapidly distinguish promising MOFs from those that are "thermodynamic dead-ends" will be helpful in guiding synthesis efforts towards promising compounds.

  7. Nanoscale capillary freezing of ionic liquids confined between metallic interfaces and the role of electronic screening

    PubMed Central

    Comtet, Jean; Niguès, Antoine; Kaiser, Vojtech; Coasne, Benoit; Bocquet, Lydéric; Siria, Alessandro

    2017-01-01

    Room temperature Ionic liquids (RTIL) are new materials with fundamental importance for energy storage and active lubrication. They are unsual liquids, which challenge the classical frameworks of electrolytes, whose behavior at electrified interfaces remains elusive with exotic responses relevant to their electrochemical activity. By means of tuning fork based AFM nanorheological measurements, we explore here the properties of confined RTIL, unveiling a dramatic change of the RTIL towards a solid-like phase below a threshold thickness, pointing to capillary freezing in confinement. This threshold is related to the metallic nature of the confining materials, with more metallic surfaces facilitating freezing. This is interpreted in terms of the shift of freezing transition, taking into account the influence of the electronic screening on RTIL wetting of the confining surfaces. Our findings provide fresh views on the properties of confined RTIL with implications for their properties inside nanoporous metallic structures and suggests applications to tune nanoscale lubrication with phase-changing RTIL, by varying the nature and patterning of the substrate, and application of active polarisation. PMID:28346432

  8. Nanoscale capillary freezing of ionic liquids confined between metallic interfaces and the role of electronic screening.

    PubMed

    Comtet, Jean; Niguès, Antoine; Kaiser, Vojtech; Coasne, Benoit; Bocquet, Lydéric; Siria, Alessandro

    2017-06-01

    Room-temperature ionic liquids (RTILs) are new materials with fundamental importance for energy storage and active lubrication. They are unusual liquids, which challenge the classical frameworks of electrolytes, whose behaviour at electrified interfaces remains elusive, with exotic responses relevant to their electrochemical activity. Using tuning-fork-based atomic force microscope nanorheological measurements, we explore here the properties of confined RTILs, unveiling a dramatic change of the RTIL towards a solid-like phase below a threshold thickness, pointing to capillary freezing in confinement. This threshold is related to the metallic nature of the confining materials, with more metallic surfaces facilitating freezing. This behaviour is interpreted in terms of the shift of the freezing transition, taking into account the influence of the electronic screening on RTIL wetting of the confining surfaces. Our findings provide fresh views on the properties of confined RTIL with implications for their properties inside nanoporous metallic structures, and suggests applications to tune nanoscale lubrication with phase-changing RTILs, by varying the nature and patterning of the substrate, and application of active polarization.

  9. Nanoscale capillary freezing of ionic liquids confined between metallic interfaces and the role of electronic screening

    NASA Astrophysics Data System (ADS)

    Comtet, Jean; Niguès, Antoine; Kaiser, Vojtech; Coasne, Benoit; Bocquet, Lydéric; Siria, Alessandro

    2017-06-01

    Room-temperature ionic liquids (RTILs) are new materials with fundamental importance for energy storage and active lubrication. They are unusual liquids, which challenge the classical frameworks of electrolytes, whose behaviour at electrified interfaces remains elusive, with exotic responses relevant to their electrochemical activity. Using tuning-fork-based atomic force microscope nanorheological measurements, we explore here the properties of confined RTILs, unveiling a dramatic change of the RTIL towards a solid-like phase below a threshold thickness, pointing to capillary freezing in confinement. This threshold is related to the metallic nature of the confining materials, with more metallic surfaces facilitating freezing. This behaviour is interpreted in terms of the shift of the freezing transition, taking into account the influence of the electronic screening on RTIL wetting of the confining surfaces. Our findings provide fresh views on the properties of confined RTIL with implications for their properties inside nanoporous metallic structures, and suggests applications to tune nanoscale lubrication with phase-changing RTILs, by varying the nature and patterning of the substrate, and application of active polarization.

  10. Transition-metal-free catalysts for the sustainable epoxidation of alkenes: from discovery to optimisation by means of high throughput experimentation.

    PubMed

    Lueangchaichaweng, Warunee; Geukens, Inge; Peeters, Annelies; Jarry, Benjamin; Launay, Franck; Bonardet, Jean-Luc; Jacobs, Pierre A; Pescarmona, Paolo P

    2012-02-01

    Transition-metal-free oxides were studied as heterogeneous catalysts for the sustainable epoxidation of alkenes with aqueous H₂O₂ by means of high throughput experimentation (HTE) techniques. A full-factorial HTE approach was applied in the various stages of the development of the catalysts: the synthesis of the materials, their screening as heterogeneous catalysts in liquid-phase epoxidation and the optimisation of the reaction conditions. Initially, the chemical composition of transition-metal-free oxides was screened, leading to the discovery of gallium oxide as a novel, active and selective epoxidation catalyst. On the basis of these results, the research line was continued with the study of structured porous aluminosilicates, gallosilicates and silica-gallia composites. In general, the gallium-based materials showed the best catalytic performances. This family of materials represents a promising class of heterogeneous catalysts for the sustainable epoxidation of alkenes and offers a valid alternative to the transition-metal heterogeneous catalysts commonly used in epoxidation. High throughput experimentation played an important role in promoting the development of these catalytic systems.

  11. Critical Metals in Strategic Low-carbon Energy Technologies

    NASA Astrophysics Data System (ADS)

    Moss, R. L.

    2012-04-01

    Due to the rapid growth in demand for certain materials, compounded by political risks associated with the geographical concentration of the supply of them, shortages of materials could be a potential bottleneck to the deployment of low-carbon energy technologies. Consequently, an assessment has been carried out to ascertain whether such shortages could jeopardise the objectives of the EU's Strategic Energy Technology Plan (SET-Plan), especially in the six low-carbon energy technologies of SET-Plan, namely: nuclear, solar, wind, bioenergy, carbon capture and storage (CCS) and electricity grids. The assessment identified 14 metals for which the deployment of the six technologies will require 1% or more (and in some cases, much more) of current world supply per annum between 2020 and 2030. Following a more critical examination, based on the likelihood of rapid future global demand growth, limitations to expanding supply in the short to medium term, and the concentration of supply and political risks associated with key suppliers, 5 of the 14 metals were pinpointed to be at high risk, namely: the rare earth metals neodymium and dysprosium (for wind technology), and the by-products (from the processing of other metals) indium, tellurium and gallium (for photovoltaic technologies). In addition, the work has explored potential mitigation strategies, ranging from expanding European output, increasing recycling and reuse to reducing waste and finding substitutes for these metals in their main applications. Furthermore, recommendations are provided which include closely working with the EU's Raw Materials Initiative; supporting efforts to ensure reliable supply of ore concentrates at competitive prices; promoting R&D and demonstration projects on new lower cost separation processes; and promoting the further development of recycling technologies and increasing end-of-life collection

  12. Development of economical improved thick film solar cell contact

    NASA Technical Reports Server (NTRS)

    Ross, B.

    1979-01-01

    Metal screened electrodes were investigated with base metal pastes and silver systems being focused upon. Contact resistance measurements were refined. A facility allowing fixing in hydrogen and other atmospheres was acquired. Several experiments were made applying screenable pastes to solar cells. Doping investigations emphasized eutectic alloys reduced to powders. Metal systems were reviewed and base metal experiments were done with nickel and copper using lead and tin as the frit metals. Severe adhesion problems were experienced with hydrogen atmospheres in all metal systems. A two step firing schedule was devised. Aluminum-silicon and aluminum-germanium eutectic doping additions to copper pastes were tried on 2 1/4 in diameter solar cell back contacts, both with good results.

  13. Soil-plant transfer models for metals to improve soil screening value guidelines valid for São Paulo, Brazil.

    PubMed

    Dos Santos-Araujo, Sabrina N; Swartjes, Frank A; Versluijs, Kees W; Moreno, Fabio Netto; Alleoni, Luís R F

    2017-11-07

    In Brazil, there is a lack of combined soil-plant data attempting to explain the influence of specific climate, soil conditions, and crop management on heavy metal uptake and accumulation by plants. As a consequence, soil-plant relationships to be used in risk assessments or for derivation of soil screening values are not available. Our objective in this study was to develop empirical soil-plant models for Cd, Cu, Pb, Ni, and Zn, in order to derive appropriate soil screening values representative of humid tropical regions such as the state of São Paulo (SP), Brazil. Soil and plant samples from 25 vegetable species in the production areas of SP were collected. The concentrations of metals found in these soil samples were relatively low. Therefore, data from temperate regions were included in our study. The soil-plant relations derived had a good performance for SP conditions for 8 out of 10 combinations of metal and vegetable species. The bioconcentration factor (BCF) values for Cd, Cu, Ni, Pb, and Zn in lettuce and for Cd, Cu, Pb, and Zn in carrot were determined under three exposure scenarios at pH 5 and 6. The application of soil-plant models and the BCFs proposed in this study can be an important tool to derive national soil quality criteria. However, this methodological approach includes data assessed under different climatic conditions and soil types and need to be carefully considered.

  14. Expandable metal stents for endoscopic bilateral stent-within-stent placement for malignant hilar biliary obstruction.

    PubMed

    Chahal, Prabhleen; Baron, Todd H

    2010-01-01

    Placement of biliary stents is effective for palliation of unresectable hilar malignant biliary obstruction. However, when bilateral self-expandable metal stents (SEMSs) are used, placement can be technically challenging. In many studies, side-by-side placement is performed, although it is unclear whether this is the most anatomical and functional approach. We sought to assess the technical feasibility and effectiveness of deploying bilateral SEMSs with a stent-within-stent approach using commercially available stents with a large cell width. Retrospective study. Tertiary care medical center. Patients with malignant biliary hilar obstruction referred for endoscopic palliation of obstructive jaundice. Technical success, ie, successful bilateral SEMS placement across the stricture; functional success, ie, decrease in pretreatment bilirubin level; early and late complications; and stent patency. Bilateral biliary drainage was attempted and successfully established in 21 patients with malignant hilar obstruction (15 men, 6 women; mean age 63.7 [standard deviation 13.9] years), resulting in clinical improvement of obstructive symptoms. Median follow-up was 6.14 months (interquartile range 3.5-9.5 months). There were 1 (5%) early and 7 (33%) late stent occlusions that required endoscopic reintervention. The 30-day mortality rate was 10% (2 deaths). Retrospective study of a series of cases treated at a tertiary care center by expert endoscopists. This simple technique was performed by using an open-cell expandable metal stent is technically feasible and easy and allows bilateral placement of SEMSs in patients with unresectable hilar malignancy. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  15. A Novel Technique for Performing PID Susceptibility Screening during the Solar Cell Fabrication Process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oh, Jaewon; Dahal, Som; Dauksher, Bill

    2016-11-21

    Various characterization techniques have historically been developed in order to screen potential induced degradation (PID)-susceptible cells, but those techniques require final solar cells. We present a new characterization technique for screening PID-susceptible cells during the cell fabrication process. Illuminated Lock-In Thermography (ILIT) was used to image PID shunting of the cell without metallization and clearly showed PID-affected areas. PID-susceptible cells can be screened by ILIT, and the sample structure can advantageously be simplified as long as the sample has the silicon nitride antireflection coating and an aluminum back surface field.

  16. Preparation and characterization of expanded graphite/metal oxides for antimicrobial application.

    PubMed

    Hung, Wei-Che; Wu, Kuo-Hui; Lyu, Dong-Yi; Cheng, Ken-Fa; Huang, Wen-Chien

    2017-06-01

    Composite materials based on expanded graphite (EG) and metal oxide (MO) particles was prepared by an explosive combustion and blending method. The objective of the study was to develop EG impregnated with metal oxide particulates (Ag 2 O, CuO and ZnO) and evaluate the level of protection the materials conferred against biological agents. The physical properties of the EG/MO composites were examined using SEM, EDX and XRD spectroscopy, and the results indicated that the MO particles were incorporated into the EG matrix after impregnation. The antimicrobial activities of the EG/MO composites against Gram-positive bacteria, Gram-negative bacteria and Bacillus anthracis were investigated using zone of inhibition, minimum inhibitory concentration (MIC), minimum bactericidal concentration (MBC) and plate-counting methods. EG/Ag 2 O exhibited a stronger antibacterial activity than EG/CuO and EG/ZnO, with a MIC of 0.3mg/mL and a MBC of 0.5mg/mL. To the best of our knowledge, few studies have demonstrated that EG/MO composites can inhibit the growth of Bacillus anthracis-adhered cells, thus preventing the process of biofilm formation. Nanoscale metal oxides display enhanced reactive properties toward bacteria due to their high surface area, large number of highly reactive edges, corner defect sites and high surface to volume ratio. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Electromagnetic Spacecraft Used for Magnetic Navigation Within Asteroid Belt, Mining Concepts and Asteroid Magnetic Classification

    NASA Astrophysics Data System (ADS)

    Kletetschka, G.; Adachi, T.; Mikula, V.

    2007-03-01

    Application of expandable/collapsible magnetic coil increases/decreases spacecraft velocity without using chemical propellants, allows effective mining of metals from asteroids and is used for the first order classification of asteroids.

  18. The role of acoustic screens in distribution of technogenic magnetic particles and chemical pollution in roadside soil

    NASA Astrophysics Data System (ADS)

    Wawer, Małgorzata; Magiera, Tadeusz; Szuszkiewicz, Marcin

    2015-04-01

    Roads constructed nowadays should by all means be functional for their motorized users but at the same time their effect on the environment ought to be limited to the minimum. Despite the existence of various methods for preventing from negative influence of roads on the environment, there is still lack of adequate techniques to monitor and reduce the spreading of roadside pollution in the air and soils. The aim of the study was to assess the influence of acoustic screens on spreading and deposition of solid pollutants deriving from car emissions, based on their quantitative and qualitative analysis. During this study, measurements of magnetic susceptibility and analyses of heavy metals as well as Pt and Rh contents in soil and plant samples (Taraxacum officinale, Plantago major, Parthenocissus quinquefolia) collected near different kinds of acoustic screens ("green walls", Plexiglass, sawdust concrete, steel panels and earth embankments) have been done. Previous investigations showed showed that most of traffic emission is deposited in the close vicinity of the roads (up to 10 m) and the level of contamination decreased with increasing distance from the road edge. However, the results of this project indicate that, in the area where the acoustic screens are located, this distribution is disturbed and the additional enrichment of heavy metals in soil about 10 - 15 m behind screens is observed. Spatial distribution of heavy metal contents in soil samples corresponds to its magnetic susceptibility values. High contents of Fe, Zn, Mn and Pb was observed next to acoustic screens made of sawdust concrete and steel panels. Additionally, concentration of Zn in soil samples collected close to these screens exceeded threshold value. Analyses of plants showed that the highest content of examined elements and highest values of magnetic susceptibility were recorded near road edge. What is more, samples of Parthenocissus quinquefolia collected at height 0.2 m were characterized by higher contents of Cu, Pb, Zn, Mn and Fe and higher magnetic susceptibility values than samples collected at height 2 m.

  19. Interaction of Heavy Metal Ions with Carbon and Iron Based Particles

    PubMed Central

    Fialova, Dana; Kremplova, Monika; Melichar, Lukas; Kopel, Pavel; Hynek, David; Adam, Vojtech; Kizek, Rene

    2014-01-01

    Due to the rapid development of industry and associated production of toxic waste, especially heavy metals, there is a great interest in creating and upgrading new sorption materials to remove these pollutants from the environment. This study aims to determine the effectiveness of different carbon forms (graphene, expanded carbon, multi-wall nanotubes) and paramagnetic particles (Fe2O3) for adsorption of cadmium(II), lead(II), and copper(II) on its surface, with different interaction time from 1 min to 24 h. The main attention is paid to the detection of these metals using differential pulse voltammetry. Based on the obtained results, graphene and Fe2O3 are found to be good candidates for removal of heavy metals from the environment. PMID:28788566

  20. [Expandable metal mesh stents for treatment of tracheal stenoses and tracheomalacia].

    PubMed

    Müller, C; Dienemann, H; Hoffmann, H; Berger, H; Storck, M; Jolk, A; Schildberg, F W

    1993-01-01

    The treatment of tracheo-bronchial stenosis or tracheomalacia is mainly carried out by means of resection or tracheoplastic operative strategies. Since the introduction of metal-mesh stents, a definitive endoluminal therapy has to be considered under new aspects. Six patients with malignant stenosis or tracheomalacia due to compression were treated by implantation of Palmaz- or Wallstents. Immediately after the implantation, patients were relieved from dyspnoea, the forced inspiratory volume-1 (FIV1) was normalized. All implanted stents were well tolerated, even in the long-time follow-up (19 months). Bronchoscopic control showed overgrowth of the metal meshes by respiratory epithelium. The implantation of metal-mesh stents is an adequate alternative in the treatment of malignant stenosis and tracheomalacia.

  1. Clinical Application of Fully Covered Self-Expandable Metal Stents in the Treatment of Bronchial Fistula.

    PubMed

    Cao, Ming; Zhu, Qiang; Wang, Wei; Zhang, Tian Xiao; Jiang, Min Zhong; Zang, Qi

    2016-09-01

    Background The study was designed to access the feasibility, safety, and efficacy of fully covered self-expandable metal stents in the treatment of bronchial fistula. Methods Clinical data of nine patients (seven males and two females) who were treated with placement of tracheobronchial or bronchial fully covered self-expandable metal stents from August 2005 to November 2011 were analyzed retrospectively. Among these patients, seven were diagnosed with bronchopleural fistula, one with tracheopleural fistula, and one with left main bronchoesophageal fistula. Eight had accompanying thoracic empyema. The fistula orifices ranged from 3.5 mm to 25 mm in diameter. All patients received topical anesthesia. L-shaped stents were placed in six patients and I-shaped stents in three under fluoroscopic guidance. After stent placement, patients with empyema were treated with pleural lavage. Results Stent placement in the tracheobronchial tree was successful in all patients, without procedure-related complications. The operating time was 5 to 16 minutes. A small amount of bubble overflowed from the intrathoracic drainage tube of only one patient. In the other patients, the bubble in the intrathoracic drainage tube disappeared immediately or angiography showed no overflow of contrast agent from the fistula orifice. The effective rate of fistula orifice closure after stent placement was 100%, with 88.9% rated as excellent. One patient coughed the stent out 5 days after placement and hence a new stent was placed. Among the patients with empyema, one died of septicemia arising from empyema on day 8 and another died of brain metastases of lung cancer 6 months after stent insertion with persistent empyema. In the other six patients, empyema resolved after 2 to 5 months (cure rate 75%). Seven patients were followed up for 3 to 36 months. During follow-up, one stent was removed 8 months after implantation due to difficult expectoration, without recurrent empyema. The remaining patients tolerated the stents well. The stents remained stable without migration or empyema recurrence, and they could eat and drink well. Conclusion The use of fully covered self-expandable metal stents is a safe, effective, and fast minimally invasive method to treat bronchial fistula, especially for selected cases with empyema. Georg Thieme Verlag KG Stuttgart · New York.

  2. [Trimming with argon plasma of self-expanding metal stents: report of 7 cases].

    PubMed

    Jury, Gastón; Amieva, Leandro; López, Fagalde Rafael; Jury, Rubén

    2014-06-01

    The use of self-expandable enteral stents for palliation of malignant stenosis may present the complication of concealing the ampulla of Vater behind the metallic mesh. Anchoring in the duodenal wall (distal or partial migration) may also be a complication of biliary metallic stents and therefore may cause difficulty in gaining access to the biliary tract. In these cases of difficult access, a fenestration on the prosthesis ( biliary or enteral) can be created to allow reaching the obstructed biliary tract by means of argon plasma (AP). Were retrospectively analysed 7 cases. Under endoscopic vision, AP was directed to filgurate and cut 6 biliary prosthesis and a duodenal stent. Fulguration and cut of biliary stent was performed in 5 cases of distal partial migration and cholangitis. In one case of obstruction caused by distal migration inside the duodenal stent light, cutting of the biliary stent was performed. A window was created in the enteral prosthesis in order to access the ampulla of Vater and place a biliary tract prosthesis. All cases were resolved successfully and without complications. We conclude that the use of AP to fulgurate and cut nitinol prosthesis was effective and presented no complications in this series.

  3. A new device for slow progressive narrowing of vessels.

    PubMed

    Lange, P E; Sievers, H H; Nürnberg, J H; Engler, K; Pilarczyk, J; Onnasch, D G; Bernhard, A; Heintzen, P H

    1985-01-01

    The purpose of this work was to develop a device which allows slow progressive banding of a great artery in infants within 4 to 5 weeks. Employed was the hygroscopic casein ameroid. When brought in contact with fluids, an ameroid cylinder expands characteristically. An early phase of fast expansion proceeds gradually to a phase of slow growth. Size, shape, and encasement of ameroid as well as temperature and type of surrounding fluid modify but do not alter the typical pattern of expansion. The developed constrictor (weight: 5.8 kg, length: 18 mm, diameter: 12 mm) includes a stainless steel socket containing an ameroid cylinder (length: 8.5 mm, diameter: 8 mm). The expanding ameroid pushes a piston with a concave extension (makrolon) a maximum of 2 mm against the artery, which is fixed to the metal housing by a teflon band (width: 4 mm, thickness: 0.5 mm). The band runs in 2 fitting grooves on the metal housing to which it is fixed by a metal ring with a precisely manufactured internal thread allowing exact tightening and loosening of the band around the artery. Utilization of inert materials like teflon, makrolon, and stainless steel warrants experimental and possibly clinical application of the developed small constrictor.

  4. Society of Behavioral Medicine supports implementation of high quality lung cancer screening in high-risk populations.

    PubMed

    Watson, Karriem S; Blok, Amanda C; Buscemi, Joanna; Molina, Yamile; Fitzgibbon, Marian; Simon, Melissa A; Williams, Lance; Matthews, Kameron; Studts, Jamie L; Lillie, Sarah E; Ostroff, Jamie S; Carter-Harris, Lisa; Winn, Robert A

    2016-12-01

    The Society of Behavioral Medicine (SBM) supports the United States Preventive Services Task Force (USPSTF) recommendation of low-dose computed tomography (LDCT) screening of the chest for eligible populations to reduce lung cancer mortality. Consistent with efforts to translate research findings into real-world settings, SBM encourages health-care providers and health-care systems to (1) integrate evidence-based tobacco treatment as an essential component of LDCT-based lung cancer screening, (2) examine the structural barriers that may impact screening uptake, and (3) incorporate shared decision-making as a clinical platform to facilitate consultations and engagement with individuals at high risk for lung cancer about the potential benefits and harms associated with participation in a lung cancer screening program. We advise policy makers and legislators to support screening in high-risk populations by continuing to (1) expand access to high quality LDCT-based screening among underserved high-risk populations, (2) enhance cost-effectiveness by integrating evidence-based tobacco treatments into screening in high-risk populations, and (3) increase funding for research that explores implementation science and increased public awareness and access of diverse populations to participate in clinical and translational research.

  5. Industrial filter bags cleaned by high-frequency vibration: A concept

    NASA Technical Reports Server (NTRS)

    Kooy, A. V.

    1973-01-01

    System holds filter bag around fine-mesh metal screen and vibrates screen at its resonant frequency. This removes deposited byproducts and protects bag fibers from damaging forces. Because filter bags represent 20 to 40% of any industrial filtering investment, this method of extending bag life should be of interest to those responsible for plant maintenance.

  6. In vitro screening of metal oxide nanoparticles for effects on neural function using cortical networks on microelectrode arrays

    EPA Science Inventory

    Nanoparticles (NPs) may translocate to the brain following inhalation or oral exposures, yet higher throughput methods to screen NPs for potential neurotoxicity are lacking. The present study examined effects of 5 Ce02 (5- 1288 nm), and 4 Ti02 (6-142 nm) NPs and microparticles (M...

  7. Implications of newborn screening for nurses.

    PubMed

    DeLuca, Jane; Zanni, Karen L; Bonhomme, Natasha; Kemper, Alex R

    2013-03-01

    Newborn screening has dramatically decreased the morbidity and mortality associated with a wide range of heritable conditions. Continuing advances in screening technology and improvements in the effectiveness of treatment are driving the rapid expansion of newborn screening programs. In this article, we review issues in newborn screening care and opportunities for nurses and nursing faculty to provide education and conduct research to improve the impact of newborn screening. This article provides (a) an overview of current newborn screening activities, including how conditions are added to newborn screening panels and how implementation occurs at state and national levels; (b) a description of current controversies and ethical considerations; (c) a description of the roles of nurses in the newborn screening process; (d) suggestions for nursing education and research; and (e) a summary of expected future developments in newborn screening, including genome sequencing. Nurses are uniquely well suited to address the educational needs and future research in newborn screening because of the role that nurses play in the provision of direct clinical care and in population-based healthcare delivery. Newborn screening is a public health approach to the identification of rare but treatable conditions in early infancy. In the United States, as in other industrialized countries, newborn screening is rapidly expanding. Nurses, nurse educators, and nurse researchers are positioned to contribute to the field of newborn screening by assuring programs are implemented safely and effectively, by facilitating education of the nursing work force, and by developing and contributing to research programs in newborn screening. © 2013 Sigma Theta Tau International.

  8. Molecular orbital imaging of cobalt phthalocyanine on native oxidized copper layers using STM.

    PubMed

    Guo, Qinmin; Huang, Min; Qin, Zhihui; Cao, Gengyu

    2012-07-01

    To observe molecular orbitals using scanning tunneling microscopy, well-ordered oxidized layers on Cu(001) were fabricated to screen the individual adsorbed cobalt phthalocyanine (CoPc) molecules from the electronic influence of the metal surface. Scanning tunneling microscope images of the molecule on this oxidized layer show similarities to the orbital distribution of the free molecule. The good match between the differential conductance mapping images and the calculated charge distribution at energy levels corresponding to the frontier orbitals of CoPc provides more evidence of the screening of the oxidized layer from interactions between the metal surface and supported molecules. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Frequency-Independent Response of Self-Complementary Checkerboard Screens

    NASA Astrophysics Data System (ADS)

    Urade, Yoshiro; Nakata, Yosuke; Nakanishi, Toshihiro; Kitano, Masao

    2015-06-01

    This research resolves a long-standing problem on the electromagnetic response of self-complementary metallic screens with checkerboardlike geometry. Although Babinet's principle implies that they show a frequency-independent response, this unusual characteristic has not been observed yet due to the singularities of the metallic point contacts in the checkerboard geometry. We overcome this difficulty by replacing the point contacts with resistive sheets. The proposed structure is prepared and characterized by terahertz time-domain spectroscopy. It is experimentally confirmed that the resistive checkerboard structures exhibit a flat transmission spectrum over 0.1-1.1 THz. It is also demonstrated that self-complementarity can eliminate even the frequency-dependent transmission characteristics of resonant metamaterials.

  10. Discovery of Overcoating Metal Oxides on Photoelectrode for Water Splitting by Automated Screening.

    PubMed

    Saito, Rie; Miseki, Yugo; Nini, Wang; Sayama, Kazuhiro

    2015-10-12

    We applied an automated semiconductor synthesis and screen system to discover overcoating film materials and optimize coating conditions on the BiVO4/WO3 composite photoelectrode to enhance stability and photocurrent. Thirteen metallic elements for overcoating oxides were examined with various coating amounts. The stability of the BiVO4/WO3 photoelectrode in a highly concentrated carbonate electrolyte aqueous solution was significantly improved by overcoating with Ta2O5 film, which was amorphous and porous when calcined at 550 °C. The photocurrent for the water oxidation reaction was only minimally inhibited by the presence of the Ta2O5 film on the BiVO4/WO3 photoelectrode.

  11. Electronic transport properties of 4f shell elements of liquid metal using hard sphere Yukawa system

    NASA Astrophysics Data System (ADS)

    Patel, H. P.; Sonvane, Y. A.; Thakor, P. B.

    2018-04-01

    The electronic transport properties are analyzed for 4f shell elements of liquid metals. To examine the electronic transport properties like electrical resistivity (ρ), thermal conductivity (σ) and thermo electrical power (Q), we used our own parameter free model potential with the Hard Sphere Yukawa (HSY) reference system. The screening effect on aforesaid properties has been examined by using different screening functions like Hartree (H), Taylor (T) and Sarkar (S). The correlations of our resultsand other data with available experimental values are intensely promising. Also, we conclude that our newly constructed parameter free model potential is capable of explaining the above mentioned electronic transport properties.

  12. Screening of willow species for resistance to heavy metals: comparison of performance in a hydroponics system and field trials.

    PubMed

    Watson, C; Pulford, I D; Riddell-Black, D

    2003-01-01

    The aim of this study was to ascertain whether metal resistance in willow (Salix) clones grown in a hydroponics screening test correlated with data from the same clones grown independently in a field trial. If so, results from a short-term, glasshouse-based system could be extrapolated to the field, allowing rapid identification of willows suitable for planting in metal-contaminated substrates without necessitating longterm field trials. Principal Components Analysis was used to show groups of clones and to assess the relative importance of the parameters measured in both the hydroponics system and the field; including plant response factors such as increase in stem height, as well as metal concentrations in plant tissues. The clones tested fell into two distinct groups. Salix viminalis clones and the basket willow Black Maul (S. triandra) were less resistant to elevated concentrations of heavy metals than a group of hardier clones, including S. burjatica 'Germany,' S.x dasyclados, S. candida and S. spaethii. The more resistant clones produced more biomass in the glasshouse and field, and had higher metal concentrations in the wood. The less resistant clones had greater concentrations of Cu and Ni in the bark, and produced less biomass in the glasshouse and field. Significant relationships were found between the response of the same clones grown the in short-term glasshouse hydroponics system and in the field.

  13. Screening charge localization at LiNbO{sub 3} surface with Schottky junction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagata, Takahiro, E-mail: NAGATA.Takahiro@nims.go.jp; Chikyow, Toyohiro; Kitamura, Kenji

    2016-04-25

    Screening charge localization was demonstrated by using a Schottky contact with LiNbO{sub 3} (LN). A Cr/LN stack structure with a 2 μm diameter hole array penetrating the Cr layer localized the screening charge of LN in the hole, although the Al/LN stack structure exhibited no surface charge localization behavior. X-ray photoelectron spectroscopy revealed that Cr formed a Schottky contact with LN, which prevents the screening charge from escaping from the hole arrays. The screening charge localization was enhanced by inserting SiO{sub 2} between the metal and LN, which moved the position of the Fermi level to mid gap.

  14. As Patient Navigation Expands and Evolves, Nurses Assume Many Roles

    Cancer.gov

    It can be difficult to access care in our labyrinthine health care system. Oncology nurses are joining the ranks of patient navigators—a diverse group of people who help patients at all stages of cancer care, from screening and diagnosis to treatment and survivorship.

  15. EPA’s Non-Targeted Analysis Research Program: Expanding public data resources in support of exposure science

    EPA Science Inventory

    Suspect screening (SSA) and non-targeted analysis (NTA) methods using high-resolution mass spectrometry (HRMS) offer new approaches to efficiently generate exposure data for chemicals in a variety of environmental and biological media. These techniques aid characterization of the...

  16. Direct metal transfer printing on flexible substrate for fabricating optics functional devices

    NASA Astrophysics Data System (ADS)

    Jiang, Yingjie; Zhou, Xiaohong; Zhang, Feng; Shi, Zhenwu; Chen, Linsen; Peng, Changsi

    2015-11-01

    New functional materials and devices based on metal patterns can be widely used in many new and expanding industries,such as flat panel displays, alternative energy,sensors and so on. In this paper, we introduce a new transfer printing method for fabricating metal optics functional devices. This method can directly transfer a metal pattern from a polyethylene terephthalate (PET)supported UV or polydimethylsiloxane (PDMS) pattern to another PET substrate. Purely taking advantage of the anaerobic UV curing adhesive (a-UV) on PET substrate, metal film can be easily peeled off from micro/nano-structured surface. As a result, metal film on the protrusion can be selectively transferred onto the target substrate, to make it the metal functional surface. But which on the bottom can not be transferred. This method provides low cost fabrication of metal thin film devices by avoiding high cost lithography process. Compared with conventional approach, this method can get more smooth rough edges and has wider tolerance range for the original master mold. Future developments and potential applications of this metal transfer method will be addressed.

  17. GLOBULAR CLUSTER ABUNDANCES FROM HIGH-RESOLUTION, INTEGRATED-LIGHT SPECTROSCOPY. II. EXPANDING THE METALLICITY RANGE FOR OLD CLUSTERS AND UPDATED ANALYSIS TECHNIQUES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colucci, Janet E.; Bernstein, Rebecca A.; McWilliam, Andrew

    2017-01-10

    We present abundances of globular clusters (GCs) in the Milky Way and Fornax from integrated-light (IL) spectra. Our goal is to evaluate the consistency of the IL analysis relative to standard abundance analysis for individual stars in those same clusters. This sample includes an updated analysis of seven clusters from our previous publications and results for five new clusters that expand the metallicity range over which our technique has been tested. We find that the [Fe/H] measured from IL spectra agrees to ∼0.1 dex for GCs with metallicities as high as [Fe/H] = −0.3, but the abundances measured for more metal-rich clustersmore » may be underestimated. In addition we systematically evaluate the accuracy of abundance ratios, [X/Fe], for Na i, Mg i, Al i, Si i, Ca i, Ti i, Ti ii, Sc ii, V i, Cr i, Mn i, Co i, Ni i, Cu i, Y ii, Zr i, Ba ii, La ii, Nd ii, and Eu ii. The elements for which the IL analysis gives results that are most similar to analysis of individual stellar spectra are Fe i, Ca i, Si i, Ni i, and Ba ii. The elements that show the greatest differences include Mg i and Zr i. Some elements show good agreement only over a limited range in metallicity. More stellar abundance data in these clusters would enable more complete evaluation of the IL results for other important elements.« less

  18. Using Laser-Induced Thermal Voxels to Pattern Diverse Materials at the Solid-Liquid Interface.

    PubMed

    Zarzar, Lauren D; Swartzentruber, B S; Donovan, Brian F; Hopkins, Patrick E; Kaehr, Bryan

    2016-08-24

    We describe a high-resolution patterning approach that combines the spatial control inherent to laser direct writing with the versatility of benchtop chemical synthesis. By taking advantage of the steep thermal gradient that occurs while laser heating a metal edge in contact with solution, diverse materials comprising transition metals are patterned with feature size resolution nearing 1 μm. We demonstrate fabrication of reduced metallic nickel in one step and examine electrical properties and air stability through direct-write integration onto a device platform. This strategy expands the chemistries and materials that can be used in combination with laser direct writing.

  19. Using laser-induced thermal voxels to pattern diverse materials at the solid–liquid interface

    DOE PAGES

    Zarzar, Lauren D.; Swartzentruber, B. S.; Donovan, Brian F.; ...

    2016-08-05

    We describe a high-resolution patterning approach that combines the spatial control inherent to laser direct writing with the versatility of benchtop chemical synthesis. By taking advantage of the steep thermal gradient that occurs while laser heating a metal edge in contact with solution, diverse materials comprising transition metals are patterned with feature size resolution nearing 1 μm. We demonstrate fabrication of reduced metallic nickel in one step and examine electrical properties and air stability through direct-write integration onto a device platform. In conclusion, this strategy expands the chemistries and materials that can be used in combination with laser direct writing.

  20. Application of Ionic Liquids in Hydrometallurgy

    PubMed Central

    Park, Jesik; Jung, Yeojin; Kusumah, Priyandi; Lee, Jinyoung; Kwon, Kyungjung; Lee, Churl Kyoung

    2014-01-01

    Ionic liquids, low temperature molten salts, have various advantages manifesting themselves as durable and environmentally friendly solvents. Their application is expanding into various fields including hydrometallurgy due to their unique properties such as non-volatility, inflammability, low toxicity, good ionic conductivity, and wide electrochemical potential window. This paper reviews previous literatures and our recent results adopting ionic liquids in extraction, synthesis and processing of metals with an emphasis on the electrolysis of active/light, rare earth, and platinum group metals. Because the research and development of ionic liquids in this area are still emerging, various, more fundamental approaches are expected to popularize ionic liquids in the metal manufacturing industry. PMID:25177864

  1. Silicon-nitride and metal composite

    DOEpatents

    Landingham, R.L.; Huffsmith, S.A.

    A composite and a method for bonding the composite are described. The composite includes a ceramic portion of silicon nitride, a refractory metal portion and a layer of MoSi/sub 2/ indirectly bonding the composite together. The method includes contacting the layer of MoSi/sub 2/ with a surface of the silicon nitride and with a surface of the metal; heating the layer to a temperature below 1400/sup 0/C; and, simultaneously, compressing the layer such that the contacting is with a pressure of at least 30 MPa. This composite overcomes useful life problems in the fabrication of parts for a helical expander for use in power generation.

  2. Silicon-nitride and metal composite

    DOEpatents

    Landingham, Richard L.; Huffsmith, Sarah A.

    1981-01-01

    A composite and a method for bonding the composite. The composite includes a ceramic portion of silicon nitride, a refractory metal portion and a layer of MoSi.sub.2 indirectly bonding the composite together. The method includes contacting the layer of MoSi.sub.2 with a surface of the silicon nitride and with a surface of the metal; heating the layer to a temperature below 1400.degree. C.; and, simultaneously with the heating, compressing the layer such that the contacting is with a pressure of at least 30 MPa. This composite overcomes useful life problems in the fabrication of parts for a helical expander for use in power generation.

  3. Screening and prioritisation of chemical risks from metal mining operations, identifying exposure media of concern.

    PubMed

    Pan, Jilang; Oates, Christopher J; Ihlenfeld, Christian; Plant, Jane A; Voulvoulis, Nikolaos

    2010-04-01

    Metals have been central to the development of human civilisation from the Bronze Age to modern times, although in the past, metal mining and smelting have been the cause of serious environmental pollution with the potential to harm human health. Despite problems from artisanal mining in some developing countries, modern mining to Western standards now uses the best available mining technology combined with environmental monitoring, mitigation and remediation measures to limit emissions to the environment. This paper develops risk screening and prioritisation methods previously used for contaminated land on military and civilian sites and engineering systems for the analysis and prioritisation of chemical risks from modern metal mining operations. It uses hierarchical holographic modelling and multi-criteria decision making to analyse and prioritise the risks from potentially hazardous inorganic chemical substances released by mining operations. A case study of an active platinum group metals mine in South Africa is used to demonstrate the potential of the method. This risk-based methodology for identifying, filtering and ranking mining-related environmental and human health risks can be used to identify exposure media of greatest concern to inform risk management. It also provides a practical decision-making tool for mine acquisition and helps to communicate risk to all members of mining operation teams.

  4. siRNA screen identifies QPCT as a druggable target for Huntington's disease.

    PubMed

    Jimenez-Sanchez, Maria; Lam, Wun; Hannus, Michael; Sönnichsen, Birte; Imarisio, Sara; Fleming, Angeleen; Tarditi, Alessia; Menzies, Fiona; Dami, Teresa Ed; Xu, Catherine; Gonzalez-Couto, Eduardo; Lazzeroni, Giulia; Heitz, Freddy; Diamanti, Daniela; Massai, Luisa; Satagopam, Venkata P; Marconi, Guido; Caramelli, Chiara; Nencini, Arianna; Andreini, Matteo; Sardone, Gian Luca; Caradonna, Nicola P; Porcari, Valentina; Scali, Carla; Schneider, Reinhard; Pollio, Giuseppe; O'Kane, Cahir J; Caricasole, Andrea; Rubinsztein, David C

    2015-05-01

    Huntington's disease (HD) is a currently incurable neurodegenerative condition caused by an abnormally expanded polyglutamine tract in huntingtin (HTT). We identified new modifiers of mutant HTT toxicity by performing a large-scale 'druggable genome' siRNA screen in human cultured cells, followed by hit validation in Drosophila. We focused on glutaminyl cyclase (QPCT), which had one of the strongest effects on mutant HTT-induced toxicity and aggregation in the cell-based siRNA screen and also rescued these phenotypes in Drosophila. We found that QPCT inhibition induced the levels of the molecular chaperone αB-crystallin and reduced the aggregation of diverse proteins. We generated new QPCT inhibitors using in silico methods followed by in vitro screening, which rescued the HD-related phenotypes in cell, Drosophila and zebrafish HD models. Our data reveal a new HD druggable target affecting mutant HTT aggregation and provide proof of principle for a discovery pipeline from druggable genome screen to drug development.

  5. Patient navigation reduces time to care for patients with breast symptoms and abnormal screening mammograms.

    PubMed

    McKevitt, Elaine; Dingee, Carol; Warburton, Rebecca; Pao, Jin-Si; Brown, Carl J; Wilson, Christine; Kuusk, Urve

    2018-05-01

    Concern has been raised about delays for patients presenting with breast symptoms in Canada. Our objective was to determine if our Rapid Access Breast Clinic (RABC) improved care for patients presenting with breast symptoms compared to the traditional system (TS). A retrospective chart review tabulated demographic, surgical, pathology and radiologic information. Wait times to care were determined for patients presenting with symptomatic and screen detected breast problems. Time from presentation to surgeon evaluation was shorter in the RABC group for patients with breast symptoms (81 vs 35 days, p < .0001) and abnormal screens (72 vs 40 days, p = .092). Cancer patients with abnormal screens had shorter wait times than patients with breast symptoms in the TS (47 vs 70 days, p = .036). Coordination of imaging and clinical care reduces wait times in patients with both abnormal screening mammograms and symptomatic breast presentations and should be expanded in our province. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. The time course of cancer detection performance

    NASA Astrophysics Data System (ADS)

    Taylor-Phillips, Sian; Clarke, Aileen; Wallis, Matthew; Wheaton, Margot; Duncan, Alison; Gale, Alastair G.

    2011-03-01

    The purpose of this study was to measure how mammography readers' performance varies with time of day and time spent reading. This was investigated in screening practice and when reading an enriched case set. In screening practice records of time and date that each case was read, along with outcome (whether the woman was recalled for further tests, and biopsy results where performed) was extracted from records from one breast screening centre in UK (4 readers). Patterns of performance with time spent reading was also measured using an enriched test set (160 cases, 41% malignant, read three times by eight radiologists). Recall rates varied with time of day, with different patterns for each reader. Recall rates decreased as the reading session progressed both when reading the enriched test set and in screening practice. Further work is needed to expand this work to a greater number of breast screening centres, and to determine whether these patterns of performance over time can be used to optimize overall performance.

  7. Scaling up cervical cancer screening in the midst of human papillomavirus vaccination advocacy in Thailand.

    PubMed

    Yothasamut, Jomkwan; Putchong, Choenkwan; Sirisamutr, Teera; Teerawattananon, Yot; Tantivess, Sripen

    2010-07-02

    Screening tests for cervical cancer are effective in reducing the disease burden. In Thailand, a Pap smear program has been implemented throughout the country for 40 years. In 2008 the Ministry of Public Health (MoPH) unexpectedly decided to scale up the coverage of free cervical cancer screening services, to meet an ambitious target. This study analyzes the processes and factors that drove this policy innovation in the area of cervical cancer control in Thailand. In-depth interviews with key policy actors and review of relevant documents were conducted in 2009. Data analysis was guided by a framework, developed on public policy models and existing literature on scaling-up health care interventions. Between 2006 and 2008 international organizations and the vaccine industry advocated the introduction of Human Papillomavirus (HPV) vaccine for the primary prevention of cervical cancer. Meanwhile, a local study suggested that the vaccine was considerably less cost-effective than cervical cancer screening in the Thai context. Then, from August to December 2008, the MoPH carried out a campaign to expand the coverage of its cervical cancer screening program, targeting one million women. The study reveals that several factors were influential in focusing the attention of policymakers on strengthening the screening services. These included the high burden of cervical cancer in Thailand, the launch of the HPV vaccine onto the global and domestic markets, the country's political instability, and the dissemination of scientific evidence regarding the appropriateness of different options for cervical cancer prevention. Influenced by the country's political crisis, the MoPH's campaign was devised in a very short time. In the view of the responsible health officials, the campaign was not successful and indeed, did not achieve its ambitious target. The Thai case study suggests that the political crisis was a crucial factor that drew the attention of policymakers to the cervical cancer problem and led the government to adopt a policy of expanding coverage of screening services. At the same time, the instability in the political system impeded the scaling up process, as it constrained the formulation and implementation of the policy in the later phase.

  8. Scaling up cervical cancer screening in the midst of human papillomavirus vaccination advocacy in Thailand

    PubMed Central

    2010-01-01

    Background Screening tests for cervical cancer are effective in reducing the disease burden. In Thailand, a Pap smear program has been implemented throughout the country for 40 years. In 2008 the Ministry of Public Health (MoPH) unexpectedly decided to scale up the coverage of free cervical cancer screening services, to meet an ambitious target. This study analyzes the processes and factors that drove this policy innovation in the area of cervical cancer control in Thailand. Methods In-depth interviews with key policy actors and review of relevant documents were conducted in 2009. Data analysis was guided by a framework, developed on public policy models and existing literature on scaling-up health care interventions. Results Between 2006 and 2008 international organizations and the vaccine industry advocated the introduction of Human Papillomavirus (HPV) vaccine for the primary prevention of cervical cancer. Meanwhile, a local study suggested that the vaccine was considerably less cost-effective than cervical cancer screening in the Thai context. Then, from August to December 2008, the MoPH carried out a campaign to expand the coverage of its cervical cancer screening program, targeting one million women. The study reveals that several factors were influential in focusing the attention of policymakers on strengthening the screening services. These included the high burden of cervical cancer in Thailand, the launch of the HPV vaccine onto the global and domestic markets, the country’s political instability, and the dissemination of scientific evidence regarding the appropriateness of different options for cervical cancer prevention. Influenced by the country’s political crisis, the MoPH’s campaign was devised in a very short time. In the view of the responsible health officials, the campaign was not successful and indeed, did not achieve its ambitious target. Conclusion The Thai case study suggests that the political crisis was a crucial factor that drew the attention of policymakers to the cervical cancer problem and led the government to adopt a policy of expanding coverage of screening services. At the same time, the instability in the political system impeded the scaling up process, as it constrained the formulation and implementation of the policy in the later phase. PMID:20594371

  9. Packer arrangements for oil wells and the like

    DOEpatents

    Harvey, Andrew C.; McFadden, David H.

    1981-11-24

    The packer includes an elongated tubular casing, and a metal ring is disposed in its entirety within an annular recess in the casing. The recess has a circumferential opening extending entirely around the peripheral outer surface of the casing. Hydraulic fluid is flowed into the recess to apply pressure to the inner peripheral surface of the metal ring to expand the ring radially outwardly and force its outer peripheral surface through the circumferential opening and into annular sealing engagement with the opposed surface of the well casing.

  10. Engineering of Transition Metal Catalysts Confined in Zeolites

    PubMed Central

    2018-01-01

    Transition metal–zeolite composites are versatile catalytic materials for a wide range of industrial and lab-scale processes. Significant advances in fabrication and characterization of well-defined metal centers confined in zeolite matrixes have greatly expanded the library of available materials and, accordingly, their catalytic utility. In this review, we summarize recent developments in the field from the perspective of materials chemistry, focusing on synthesis, postsynthesis modification, (operando) spectroscopy characterization, and computational modeling of transition metal–zeolite catalysts. PMID:29861546

  11. Biosorption process for removing heavy metal ions using water milfoil (Myriophyllum Spicatum) in contaminated water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, T.C.; Weissman, J.C.; Varadarajan, R.

    1995-12-31

    A small scale biomass metal contacting experiment was performed to screen the optimal plant species for biosorption and bioaccumulation of cadmium, zinc, nickel, lead, and copper. Experiments were also conducted to test the ability of the biomass to lower the metal concentrations below the US Environmental Protection Agency surface water discharge criteria. The minimum residual concentration was 0.1 mg/L for zinc, 0.004 mg/L for lead, and about 0.01 mg/L for cadmium, nickel, and lead. Results indicate that water milfoil can be used for bioremoval of metals.

  12. Neuropsychological screening as a standard of care during discharge from psychiatric hospitalization: the preliminary psychometrics of the CNS Screen.

    PubMed

    Levy, Boaz; Celen-Demirtas, Selda; Surguladze, Tinatin; Eranio, Sara; Ellison, James

    2014-03-30

    Cost-prohibitive factors currently prevent a warranted integration of neuropsychological screenings into routine psychiatric evaluations, as a standard of care. To overcome this challenge, the current study examined the psychometric properties of a new computerized measure-the CNS Screen. One hundred and twenty six psychiatric inpatients completed the CNS Screen, the Montreal Cognitive Assessment (MoCA), and the Quick Inventory of Depressive Symptomatology-Self Rated (QIDS-SR₁₆) on the day of hospital discharge. Statistical analysis established convergent validity with a moderate correlation between the self-administered CNS Screen and the clinician-administered MoCA (r=0.64). Discriminant validity was implicated by a non-significant correlation with the QIDS-SR₁₆. Concurrent validity was supported by a moderate, negative correlation with patients' age (r=-0.62). In addition, consistent with previous findings, patients with psychotic disorders exhibited significantly poorer performance on the CNS Screen than patients with a mood disorder. Similarly, patients with a formal disability status scored significantly lower than other patients. The CNS Screen was well tolerated by all patients. With further development, this type of measure may provide a cost-effective approach to expanding neuropsychological screenings on inpatient psychiatric units. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Using Curriculum-Based Measurements for Program Evaluation: Expanding Roles for School Psychologists

    ERIC Educational Resources Information Center

    Tusing, Mary E.; Breikjern, Nicholle A.

    2017-01-01

    Educators increasingly need to evaluate schoolwide reform efforts; however, complex program evaluations often are not feasible in schools. Through a case example, we provide a heuristic for program evaluation that is easily replicated in schools. Criterion-referenced interpretations of schoolwide screening data were used to evaluate outcomes…

  14. Chemical-Gene Interactions from ToxCast Bioactivity Data Expands Universe of Literature Network-Based Associations (SOT)

    EPA Science Inventory

    Characterizing the effects of chemicals in biological systems is often summarized by chemical-gene interactions, which have sparse coverage in the literature. The ToxCast chemical screening program has produced bioactivity data for nearly 2000 chemicals and over 450 gene targets....

  15. SCREENING PROCESSED MILK FOR VOLATILE ORGANIC COMPOUNDS USING VACUUM DISTILLATION/GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    EPA Science Inventory

    An adaptation of Office of Solid Waste and Emergency Response' Test Methods for Evaluating Solid Waste Physical/Chemical Methods (SW-846) method 8261 to analyze milk for an expanded list of volatile organic compounds is presented. The milk matriz exhibits a strong affinity for o...

  16. Screening study of select cotton-based hydromulch blends produced using the cross-linked biofiber process

    USDA-ARS?s Scientific Manuscript database

    As global populations continue to expand, stresses placed on our renewable resources are increasing. Disturbance of native landscapes from agriculture, urbanization, or by natural evolution brings the potential for soil erosion caused by normal rain events. Increasing regulatory pressure has resulte...

  17. 20180311 - EPA’s Non-Targeted Analysis Research Program: Expanding public data resources in support of exposure science (SOT)

    EPA Science Inventory

    Suspect screening (SSA) and non-targeted analysis (NTA) methods using high-resolution mass spectrometry (HRMS) offer new approaches to efficiently generate exposure data for chemicals in a variety of environmental and biological media. These techniques aid characterization of the...

  18. 7 CFR 319.37-8 - Growing media.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... offer for importation into the United States shall be free of sand, soil, earth, and other growing media...) Approved growing media are baked expanded clay pellets, coal cinder, coir, cork, glass wool, organic and... pests, and other plant pests. The greenhouse must be free from sand and soil and must have screening...

  19. Heavy metal resistance of Thiobacillus spp. isolated from tin mining area in Bestari Jaya, Selangor

    NASA Astrophysics Data System (ADS)

    Prabhakaran, Pranesha; Ashraf, Muhammad Aqeel; Aqma, Wan Syaidatul

    2016-11-01

    Increased anthropogenic activities such as mining have contributed to accumulation of heavy metals in the environment. Microorganisms that are found in the contaminated area develop resistance toward the heavy metals after a prolonged exposure. Screenings for bacterial resistance to metal tin were conducted using isolated Thiobacillus spp. from a tin mining area at Bestari Jaya, Selangor. Two isolated Thiobacillus spp. able to show growth without inhibition up to 300 ppm. IC50 that indicate 50% inhibition of the bacterial growth for both isolates, TB1 and TB2 are 496.03 ppm and 514.27 ppm respectively under tin-stressed condition. Adaptation of these microorganisms toward heavy metal could be exploited for bioremediation of heavy metals at contaminated sites.

  20. Screenable contact structure and method for semiconductor devices

    DOEpatents

    Ross, Bernd

    1980-08-26

    An ink composition for deposition upon the surface of a semiconductor device to provide a contact area for connection to external circuitry is disclosed, the composition comprising an ink system containing a metal powder, a binder and vehicle, and a metal frit. The ink is screened onto the semiconductor surface in the desired pattern and is heated to a temperature sufficient to cause the metal frit to become liquid. The metal frit dissolves some of the metal powder and densifies the structure by transporting the dissolved metal powder in a liquid sintering process. The sintering process typically may be carried out in any type of atmosphere. A small amount of dopant or semiconductor material may be added to the ink systems to achieve particular results if desired.

  1. Use of electronic clinical reminders to increase preventive screenings in a primary care setting: blueprint from a successful process in Kodiak, Alaska.

    PubMed

    Onders, Robert; Spillane, James; Reilley, Brigg; Leston, Jessica

    2014-01-01

    The Kodiak Area Native Association (KANA) provides primary health care in Kodiak, Alaska and 6 outlying villages. KANA sought to actively improve key preventive screening rates for its patients. KANA adopted an electronic health record in 2008 and deployed national clinical reminders from the Indian Health Service for 5 key preventive screenings: tobacco use, alcohol use, depression, intimate partner violence, and a comprehensive cardiovascular exam. Clinical reminders were deployed in a 5-step process: (a) establish clinical demand, (b) pilot test reminder, (c) expand reminder to all providers, (d) measure outcomes and share results, and (e) delegate clinical reminder follow-up (primarily to nurses). Data from 2007-2011 show screening rates for all 5 measures improved considerably, to levels significantly above the national average for Indian Health Service facilities. Clinical reminders have been a key part of a multistep process to improve screening for depression, tobacco cessation, intimate partner violence, alcohol use, and cardiovascular disease. If deployed correctly, reminders are valuable tools in identifying patients who are overdue for preventive health screenings.

  2. Screening: mapping medicine's temporal spaces.

    PubMed

    Armstrong, David

    2012-02-01

    This paper examines the history of population screening through an analysis of contemporary medical journals. The term was first used in the modern sense in the inter-war years to describe the school health examination which sought to identify the early signs of disease and abnormality, a strategy which was extended to new recruits during the Second World War. After the war, screening began to target those illnesses in the civilian population which had a clear temporal trajectory, especially 'chronic' illnesses. Since the 1980s, enthusiasm for population screening has declined within the medical community: opportunistic screening has seemed more appropriate for diseases with multifactorial aetiology, and those programmes which have survived have been increasingly challenged through an expanding analysis of their potential harms. In identifying the early precursors of clinical disease in apparently normal populations, however, screening heralded the emergence of a new form of clinical practice concerned with the surveillance of 'healthy' patients within the context of new temporal spaces of illness. © 2012 The Author. Sociology of Health & Illness © 2012 Foundation for the Sociology of Health & Illness/Blackwell Publishing Ltd.

  3. Clinical outcomes, quality of life, advantages and disadvantages of metal stent placement in the upper gastrointestinal tract.

    PubMed

    Vlavianos, Panagiotis; Zabron, Abigail

    2012-03-01

    This review will discuss the immediate- and long-term success, complications and overall benefits of self-expandable metal stents (SEMSs) in malignant or benign obstruction of the oesophagus, stomach and duodenum. Over recent years, indications such as benign disease have expanded, as has SEMS diversity with self-expandable plastic stents (SEPSs) or fully covered and biodegradable stents, for example. SEMSs have been increasingly used in malignant upper gastrointestinal obstruction with many reports confirming efficacy, despite a significant complication rate. Fully covered stents are increasingly used for a variety of benign oesophageal disease, but their place in gastric outlet obstruction is still unclear. Covered and uncovered stents have different functional characteristics and stent type must be selected on an individual basis. Biodegradable stents show promise and the outcome of experience in larger patient cohorts is eagerly awaited. This area is an evolving field, in which the clinician requires up-to-date knowledge of therapeutic options to make individualized treatment choices in difficult clinical circumstances. Technical and clinical success for oesophageal or gastroduodenal SEMSs are then above 90%. Minor complications are common, but serious complications seldom occur. Biodegradable stents may be useful, especially when stenting is needed for a short period of time.

  4. The role of lymphocyte proliferation tests in assessing occupational sensitization and disease

    PubMed Central

    Hines, Stella E.; Pacheco, Karin; Maier, Lisa A.

    2018-01-01

    Purpose of Review Lymphocyte proliferation testing (LPT) is used in diagnosing occupationally-acquired delayed-type hypersensitivity. It has been used in beryllium-health effects, and it role is expanding in metal allergy. It may find application in diagnosis of other sensitizers. Recent findings Use of the beryllium LPT (BeLPT) in medical surveillance identifies beryllium sensitization at low exposure with chronic beryllium disease (CBD) that leads to physiologic impairment and need for immunosuppressive medications. New studies indicate that both beryllium exposure and genetic variation are associated with increased risk of CBD. Borderline positive BeLPTs warrant inclusion into diagnostic algorithms. Furthermore, use of LPTs to diagnose metal allergy is being proposed in diagnosis of chromium allergy and hypersensitivity to surgical implants. New occupational sensitizers continue to be identified including metalworking fluids, the sterilizing agent ortho-phthalaldehyde and the solvent parachlorobenzotrifluoride. Use of LPT in occupational surveillance to these agents, and other known sensitizers may play expanding roles. Summary Lymphocyte proliferation testing serves a valuable role in diagnosing occupational sensitization, as demonstrated with beryllium-health effects, as cases continue to be found at low exposure levels. The use of LPTs in diagnosing contact allergy is expanding, and new applications may be identified in human and animal studies. PMID:22306552

  5. Effect of patch borders on coercivity in amorphous rare earth-transition metal thin films

    NASA Technical Reports Server (NTRS)

    Patterson, G.; Fu, H.; Giles, R. C.; Mansuripur, M.

    1991-01-01

    The coercivity at the micron scale is a very important property of magneto-optical media. It is a key factor that determines the magnetic domain wall movement and domain reversal. How the coercivity is influenced by a special type of patch borders is discussed. Patch formation is a general phenomenon in growth processes of amorphous rare earth transition metal thin films. Different patches may stem from different seeds and the patch borders are formed when they merge. Though little is known about the exact properties of the borders, we may expect that the exchange interaction at the patch border is weaker than that within a patch, since there is usually a spatial gap between two patches. Computer simulations were performed on a 2-D hexagonal lattice consisting of 37 complete patches with random shape and size. From the series of simulations we may conclude that the domain in the patch with borders of 30 percent exchange strength can expand most easily to the whole lattice, because the exchange strength can expand most easily to the whole lattice, because the exchange strength of the border is not too high to prevent the domain from growing within the patch and it is not too low to prevent the domain from expanding beyond the patch.

  6. Malignant esophageal-tracheobronchial strictures: parallel placement of covered retrievable expandable nitinol stents.

    PubMed

    Nam, D H; Shin, J H; Song, H Y; Jung, G S; Han, Y M

    2006-02-01

    To assess the safety and clinical effectiveness of the parallel placement of covered retrievable expandable metallic stents in the palliative treatment of malignant esophageal and tracheobronchial strictures. Under fluoroscopic guidance, parallel stents were placed in 12 symptomatic patients with both malignant esophageal and tracheobronchial strictures. Seven of these 12 patients also had an esophagorespiratory fistula (ERF) and one patient had an esophagocutaneous fistula. Technical success, clinical improvement, complications, and survival rates were evaluated. A total of 28 esophageal and airway stents were successfully placed. The grade of dysphagia and dyspnea score significantly decreased after stent placement (P=0.002 and 0.003, respectively). ERF and esophagocutaneous fistula were sealed off in all eight patients after esophageal stent placement; however, the esophagocutaneous fistula reopened 1 month later. Complications included stent migration or expectoration (n=3), tracheal compression by the esophageal stent (n=3), new fistula development due to covering membrane degradation of the esophageal stent (n=1), and symptomatic sputum retention (n=1). Stent removal was easily performed for two stents; one migrated stent and the other with covering membrane degradation. All 12 patients died within the mean survival period of 72.50 days (range 7-375 days). Parallel placement of covered retrievable expandable metallic stents is safe and effective for the palliative treatment of malignant esophageal and tracheobronchial strictures.

  7. Multidrug-resistant tuberculosis outbreak among US-bound Hmong refugees, Thailand, 2005.

    PubMed

    Oeltmann, John E; Varma, Jay K; Ortega, Luis; Liu, Yecai; O'Rourke, Thomas; Cano, Maria; Harrington, Theresa; Toney, Sean; Jones, Warren; Karuchit, Samart; Diem, Lois; Rienthong, Dhanida; Tappero, Jordan W; Ijaz, Kashef; Maloney, Susan A

    2008-11-01

    In January 2005, tuberculosis (TB), including multidrug-resistant TB (MDR TB), was reported among Hmong refugees who were living in or had recently immigrated to the United States from a camp in Thailand. We investigated TB and drug resistance, enhanced TB screenings, and expanded treatment capacity in the camp. In February 2005, 272 patients with TB (24 MDR TB) remained in the camp. Among 17 MDR TB patients interviewed, 13 were found to be linked socially. Of 23 MDR TB isolates genotyped, 20 were similar according to 3 molecular typing methods. Before enhanced screening was implemented, 46 TB cases (6 MDR TB) were diagnosed in the United States among 9,455 resettled refugees. After enhanced screening had begun, only 4 TB cases (1 MDR TB), were found among 5,705 resettled refugees. An MDR TB outbreak among US-bound refugees led to importation of disease; enhanced pre-immigration TB screening and treatment decreased subsequent importation.

  8. Older adult mistreatment risk screening: contribution to the validation of a screening tool in a domestic setting.

    PubMed

    Lindenbach, Jeannette M; Larocque, Sylvie; Lavoie, Anne-Marise; Garceau, Marie-Luce

    2012-06-01

    ABSTRACTThe hidden nature of older adult mistreatment renders its detection in the domestic setting particularly challenging. A validated screening instrument that can provide a systematic assessment of risk factors can facilitate this detection. One such instrument, the "expanded Indicators of Abuse" tool, has been previously validated in the Hebrew language in a hospital setting. The present study has contributed to the validation of the "e-IOA" in an English-speaking community setting in Ontario, Canada. It consisted of two phases: (a) a content validity review and adaptation of the instrument by experts throughout Ontario, and (b) an inter-rater reliability assessment by home visiting nurses. The adaptation, the "Mistreatment of Older Adult Risk Factors" tool, offers a comprehensive tool for screening in the home setting. This instrument is significant to professional practice as practitioners working with older adults will be better equipped to assess for risk of mistreatment.

  9. Sintered Lining for Heat-Pipe Evaporator

    NASA Technical Reports Server (NTRS)

    Ernst, D. M.; Eastman, G. Y.

    1985-01-01

    Hotspots eliminated by lining inner wall. Distribution of heat transfer liquid in heat-pipe evaporator improved by lining inner wall with layer of sintered metal. Sintered layer takes place of layer of screen wick formerly sintered or bonded to wall. Since sintered layer always full of liquid, no hotspot of type that previously arose where former screen wick did not fit properly against wall.

  10. Rapid screening of heavy metals and trace elements in environmental samples using portable X-ray fluorescence spectrometer, A comparative study

    PubMed Central

    McComb, Jacqueline Q.; Rogers, Christian; Han, Fengxiang X.; Tchounwou, Paul B.

    2014-01-01

    With industrialization, great amounts of trace elements and heavy metals have been excavated and released on the surface of the earth and dissipated into the environments. Rapid screening technology for detecting major and trace elements as well as heavy metals in variety of environmental samples is most desired. The objectives of this study were to determine the detection limits, accuracy, repeatability and efficiency of a X-ray fluorescence spectrometer (Niton XRF analyzer) in comparison with the traditional analytical methods, inductively coupled plasma optical emission spectrometer (ICP-OES) and inductively coupled plasma optical emission spectrometer (ICP-MS) in screening of major and trace elements of environmental samples including estuary soils and sediments, contaminated soils, and biological samples. XRF is a fast and non-destructive method in measuring the total concentration of multi--elements simultaneously. Contrary to ICP-OES and ICP-MS, XRF analyzer is characterized by the limited preparation required for solid samples, non-destructive analysis, increased total speed and high throughout, the decreased production of hazardous waste and the low running costs as well as multi-elemental determination and portability in the fields. The current comparative study demonstrates that XRF is a good rapid non-destructive method for contaminated soils, sediments and biological samples containing higher concentrations of major and trace elements. Unfortunately, XRF does not have sensitive detection limits of most major and trace elements as ICP-OES or ICP-MS but it may serve as a rapid screening tool for locating hot spots of uncontaminated field soils and sediments. PMID:25861136

  11. SCA17 repeat expansion: mildly expanded CAG/CAA repeat alleles in neurological disorders and the functional implications.

    PubMed

    Chen, Chiung-Mei; Lee, Li-Ching; Soong, Bing-Wen; Fung, Hon-Chung; Hsu, Wen-Chuin; Lin, Pei-Ying; Huang, Hui-Ju; Chen, Fen-Lin; Lin, Cheng-Yueh; Lee-Chen, Guey-Jen; Wu, Yih-Ru

    2010-03-01

    Spinocerebellar ataxia type 17 (SCA17) involves the expression of a CAG/CAA expansion mutation in the gene encoding TATA-box binding protein (TBP), a general transcription initiation factor. The spectrum of SCA17 clinical presentation is broad. We screened for triplet expansion in the TBP gene in Taiwanese Parkinson's disease (PD), Alzheimer's disease (AD) and atypical parkinsonism and investigated the functional implication of expanded alleles using lymphoblastoid cells as a model. A total of 6 mildly expanded alleles (44-46) were identified in patients group. The frequency of the individuals carrying expanded alleles in PD (3/602 [0.5%]), AD (2/245 [0.8%]) and atypical parkinsonism (1/44 [2.3%]) is not significant as compared to that in the control subjects (0/644 [0.0%]). In lymphoblastoid cells, HSPA5, HSPA8 and HSPB1 expression levels in cells with expanded TBP were significantly lower than that of the control cells. Although not significantly, the levels of PARK7 protein isoforms 6.1 and 6.4 are notably increased in SCA17 lymphoblastoid cells. Treatment of TBH (tert-butyl hydroperoxide) significantly increases cell death in the cells with mildly expanded TBP. Our findings expand the spectrum of SCA17 phenotype and may contribute to our understanding of the disease. Copyright 2009 Elsevier B.V. All rights reserved.

  12. Capillary flow of amorphous metal for high performance electrode

    PubMed Central

    Kim, Se Yun; Kim, Suk Jun; Jee, Sang Soo; Park, Jin Man; Park, Keum Hwan; Park, Sung Chan; Cho, Eun Ae; Lee, Jun Ho; Song, In Yong; Lee, Sang Mock; Han, In Taek; Lim, Ka Ram; Kim, Won Tae; Park, Ju Cheol; Eckert, Jürgen; Kim, Do Hyang; Lee, Eun-Sung

    2013-01-01

    Metallic glass (MG) assists electrical contact of screen-printed silver electrodes and leads to comparable electrode performance to that of electroplated electrodes. For high electrode performance, MG needs to be infiltrated into nanometer-scale cavities between Ag particles and reacts with them. Here, we show that the MG in the supercooled state can fill the gap between Ag particles within a remarkably short time due to capillary effect. The flow behavior of the MG is revealed by computational fluid dynamics and density funtional theory simulation. Also, we suggest the formation mechanism of the Ag electrodes, and demonstrate the criteria of MG for higher electrode performance. Consequently, when Al85Ni5Y8Co2 MG is added in the Ag electrodes, cell efficiency is enhanced up to 20.30% which is the highest efficiency reported so far for screen-printed interdigitated back contact solar cells. These results show the possibility for the replacement of electroplating process to screen-printing process. PMID:23851671

  13. A Preliminary Study of the Preparation of Slurry Fuels from Vaporized Magnesium

    NASA Technical Reports Server (NTRS)

    Witzke, Walter R; Prok, George M; Walsh, Thomas J

    1954-01-01

    Slurry fuels containing extremely small particles of magnesium were prepared by concentrating the dilute slurry product resulting from the shock-cooling of magnesium metal vapors with a liquid hydrocarbon spray. A complete description of the equipment and procedure used in preparing the fuel is given. Ninety-five percent by weight of the solid particles formed by this process passed through a 100-mesh screen. The particle-size distribution of the screened fraction of one run, as determined by sedimentation analysis, indicated that 73 percent by weight of the metal particles were finer than 2 microns in equivalent spherical diameter. The purity of the solid particles ranged as high as 98.9 percent by weight of free magnesium. The screened product was concentrated by means of a bowl-type centrifuge from 0.5 to more than 50 percent by weight solids content to form an extremely viscous, clay-like mass. By addition of a surface active agent, this viscous material was converted into a pumpable slurry fuel.

  14. Rapid and Accurate Machine Learning Recognition of High Performing Metal Organic Frameworks for CO2 Capture.

    PubMed

    Fernandez, Michael; Boyd, Peter G; Daff, Thomas D; Aghaji, Mohammad Zein; Woo, Tom K

    2014-09-04

    In this work, we have developed quantitative structure-property relationship (QSPR) models using advanced machine learning algorithms that can rapidly and accurately recognize high-performing metal organic framework (MOF) materials for CO2 capture. More specifically, QSPR classifiers have been developed that can, in a fraction of a section, identify candidate MOFs with enhanced CO2 adsorption capacity (>1 mmol/g at 0.15 bar and >4 mmol/g at 1 bar). The models were tested on a large set of 292 050 MOFs that were not part of the training set. The QSPR classifier could recover 945 of the top 1000 MOFs in the test set while flagging only 10% of the whole library for compute intensive screening. Thus, using the machine learning classifiers as part of a high-throughput screening protocol would result in an order of magnitude reduction in compute time and allow intractably large structure libraries and search spaces to be screened.

  15. A Screened Hybrid DFT Study of Actinide Oxides, Nitrides, and Carbides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wen, Xiaodong; Martin, Richard L.; Scuseria, Gustavo E.

    2013-06-27

    A systematic study of the structural, electronic, and magnetic properties of actinide oxides, nitrides, and carbides (AnX1–2 with X = C, N, O) is performed using the Heyd–Scuseria–Ernzerhof (HSE) hybrid functional. Our computed results show that the screened hybrid HSE functional gives a good description of the electronic and structural properties of actinide dioxides (strongly correlated insulators) when compared with available experimental data. However, there are still some problems reproducing the electronic properties of actinide nitrides and carbides (strongly correlated metals). In addition, in order to compare with the results by HSE, the structures, electronic, and magnetic properties of thesemore » actinide compounds are also investigated in the PBE and PBE+U approximation. Interestingly, the density of states of UN obtained with PBE compares well with the experimental photoemission spectra, in contrast to the hybrid approximation. This is presumably related to the need of additional screening in the Hartree–Fock exchange term of the metallic phases.« less

  16. Metal Roofing in a "Class" by Itself.

    ERIC Educational Resources Information Center

    Nimtz, Paul D.

    1990-01-01

    The structural standing seam roof has the advantages of ease of application, low maintenance, and low life-cycle costs. Explains and illustrates how the system's concealed clip attachments are designed so that the roof panels can expand and contract independently of the insulation. (MLF)

  17. Metal/gas MHD conversion

    NASA Astrophysics Data System (ADS)

    Thibault, J. P.; Joussellin, F.; Alemany, A.; Dupas, A.

    1982-09-01

    Operation features, theory, performance, and possible spatial applications of metal/gas MHD electrical generators are described. The working principle comprises an MHD channel, surrounded by a magnet, filled with a molten, highly conductive metal into which gas is pumped. The heat of the metal expands the gas, forcing a flow through the magnetic field crossing the channel, thus creating an electrical current conducted by the metal. The gas and metal are separated by a centrifugal device and both are redirected into the channel, forming thereby a double closed circuit when the heat of the molten metal is returned to the flow. Necessary characteristics for the gas such as a fairly low vaporization temperature and nonmiscibility with the metal, are outlined, and a space system using Li-Cs or Z-K as the heat carrier kept molten by a parabolic dish system is sketched. Equations governing the fluid mechanics, thermodynamics, and the electrical generation are defined. The construction of a prototype MHD generator using a tin-water flow operating at 250 C, a temperature suitable for coupling to solar heat sources, is outlined, noting expected efficiencies of 20-30 percent.

  18. A rapid identification system for metallothionein proteins using expert system

    PubMed Central

    Praveen, Bhoopathi; Vincent, Savariar; Murty, Upadhyayula Suryanarayana; Krishna, Amirapu Radha; Jamil, Kaiser

    2005-01-01

    Metallothioneins (MT) are low molecular weight proteins mostly rich in cysteine residues with high metal content. Generally, MT proteins are responsible for regulating the intracellular supply of biologically essential metal ions and they protect cells from the deleterious effects of non-essential polarizable transition and post-transition metal ions. Due to their biological importance, proper characterization of MT is necessary. Here we describe a computer program (ID3 algorithm, a part of Artificial Intelligence) developed using available data for the rapid identification of MT. Tissue samples contains several low molecular weight proteins with different physical, chemical and biological characteristics. The described software solution proposes to categorize MT proteins without aromatic amino acids and high metal content. The proposed solution can be expanded to other types of proteins with specific known characteristics. PMID:17597844

  19. ScreenCube: A 3D Printed System for Rapid and Cost-Effective Chemical Screening in Adult Zebrafish.

    PubMed

    Monstad-Rios, Adrian T; Watson, Claire J; Kwon, Ronald Y

    2018-02-01

    Phenotype-based small molecule screens in zebrafish embryos and larvae have been successful in accelerating pathway and therapeutic discovery for diverse biological processes. Yet, the application of chemical screens to adult physiologies has been relatively limited due to additional demands on cost, space, and labor associated with screens in adult animals. In this study, we present a 3D printed system and methods for intermittent drug dosing that enable rapid and cost-effective chemical administration in adult zebrafish. Using prefilled screening plates, the system enables dosing of 96 fish in ∼3 min, with a 10-fold reduction in drug quantity compared to that used in previous chemical screens in adult zebrafish. We characterize water quality kinetics during immersion in the system and use these kinetics to rationally design intermittent dosing regimens that result in 100% fish survival. As a demonstration of system fidelity, we show the potential to identify two known chemical inhibitors of adult tail fin regeneration, cyclopamine and dorsomorphin. By developing methods for rapid and cost-effective chemical administration in adult zebrafish, this study expands the potential for small molecule discovery in postembryonic models of development, disease, and regeneration.

  20. Laser-driven high-frequency vibrations of metal blister surface

    NASA Astrophysics Data System (ADS)

    Kononenko, T. V.; Sinyavsky, M. N.; Konov, V. I.; Sentis, M.

    2013-09-01

    Time-resolved interferometric microscopy was applied to investigate laser-induced blistering of a titanium film on a silica substrate. Ablation of the titanium/silica interface by single 0.7 ns pulses within a certain fluence range results in local exfoliation of the metal film from the substrate avoiding, however, complete film destruction. Time-dependent transformation of the metal surface profile was reconstructed from the interference patterns within 0-13 ns time delay range. Transverse annular waves with typical amplitude of one hundred of nanometers and estimated traveling speed of few kilometers per second were revealed on the blister surface. The wave occurrence was attributed to fast inhomogeneous bending of the film covering the expanding blister. The resultant high-frequency (˜1 GHz) vibrations of the metal surface provide intensive inertial forces when such metalized target is used for blister-based laser-induced forward transfer of nanopowders and organic molecules.

Top