2001-12-19
KENNEDY SPACE CENTER, FLA. -- At SPACEHAB, Cape Canaveral, Fla., Commander Rick Husband works with an experiment that will be part of the mission. STS-107 is a research mission. The primary payload is the first flight of the SHI Research Double Module (SHI/RDM). The experiments range from material sciences to life sciences (many rats). Also part of the payload is the Fast Reaction Experiments Enabling Science, Technology, Applications and Research (FREESTAR) that incorporates eight high priority secondary attached shuttle experiments: Mediterranean Israeli Dust Experiment (MEIDEX), Shuttle Ozone Limb Sounding Experiment (SOLSE-2), Student Tracked Atmospheric Research Satellite for Heuristic International Networking Experiment (STARSHINE), Critical Viscosity of Xenon-2 (CVX-2), Solar Constant Experiment-3 (SOLOCON-3), Prototype Synchrotron Radiation Detector (PSRD), Low Power Transceiver (LPT), and Collisions Into Dust Experiment -2 (COLLIDE-2). STS-107 is scheduled to launch in July 2002
STS-107 Payload Specialist Ilan Ramon at SPACEHAB during training
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. - STS-107 Payload Specialist Ilan Ramon, from Israel, trains on equipment at SPACEHAB, Cape Canaveral, Fla. STS-107 is a research mission. The primary payload is the first flight of the SHI Research Double Module (SHI/RDM). The experiments range from material sciences to life sciences (many rats). Also part of the payload is the Fast Reaction Experiments Enabling Science, Technology, Applications and Research (FREESTAR) that incorporates eight high priority secondary attached shuttle experiments: Mediterranean Israeli Dust Experiment (MEIDEX), Shuttle Ozone Limb Sounding Experiment (SOLSE-2), Student Tracked Atmospheric Research Satellite for Heuristic International Networking Experiment (STARSHINE), Critical Viscosity of Xenon-2 (CVX-2), Solar Constant Experiment-3 (SOLOCON-3), Prototype Synchrotron Radiation Detector (PSRD), Low Power Transceiver (LPT), and Collisions Into Dust Experiment -2 (COLLIDE-2). STS-107 is scheduled to launch in July 2002
STS-107 Mission Specialist Kalpana Chawla at SPACEHAB during training
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. - STS-107 Mission Specialist Kalpana Chawla looks over equipment at SPACEHAB, Cape Canaveral, Fla., during crew training. STS-107 is a research mission. The primary payload is the first flight of the SHI Research Double Module (SHI/RDM). The experiments range from material sciences to life sciences (many rats). Also part of the payload is the Fast Reaction Experiments Enabling Science, Technology, Applications and Research (FREESTAR) that incorporates eight high priority secondary attached shuttle experiments: Mediterranean Israeli Dust Experiment (MEIDEX), Shuttle Ozone Limb Sounding Experiment (SOLSE-2), Student Tracked Atmospheric Research Satellite for Heuristic International Networking Experiment (STARSHINE), Critical Viscosity of Xenon-2 (CVX-2), Solar Constant Experiment-3 (SOLOCON-3), Prototype Synchrotron Radiation Detector (PSRD), Low Power Transceiver (LPT), and Collisions Into Dust Experiment -2 (COLLIDE-2). STS-107 is scheduled to launch in July 2002
2001-12-19
KENNEDY SPACE CENTER, FLA. -- STS-107 Commander Rick Husband and Mission Specialist Laurel Clark learn to work with mission-related equipment at SPACEHAB, Cape Canaveral, Fla. STS-107 is a research mission. The primary payload is the first flight of the SHI Research Double Module (SHI/RDM). The experiments range from material sciences to life sciences (many rats). Also part of the payload is the Fast Reaction Experiments Enabling Science, Technology, Applications and Research (FREESTAR) that incorporates eight high priority secondary attached shuttle experiments: Mediterranean Israeli Dust Experiment (MEIDEX), Shuttle Ozone Limb Sounding Experiment (SOLSE-2), Student Tracked Atmospheric Research Satellite for Heuristic International Networking Experiment (STARSHINE), Critical Viscosity of Xenon-2 (CVX-2), Solar Constant Experiment-3 (SOLOCON-3), Prototype Synchrotron Radiation Detector (PSRD), Low Power Transceiver (LPT), and Collisions Into Dust Experiment -2 (COLLIDE-2). STS-107 is scheduled to launch in July 2002
2002-01-10
KENNEDY SPACE CENTER, FLA. - STS-107 Payload Specialist Ilan Ramon, from Israel, trains on equipment at SPACEHAB, Cape Canaveral, Fla. STS-107 is a research mission. The primary payload is the first flight of the SHI Research Double Module (SHI/RDM). The experiments range from material sciences to life sciences (many rats). Also part of the payload is the Fast Reaction Experiments Enabling Science, Technology, Applications and Research (FREESTAR) that incorporates eight high priority secondary attached shuttle experiments: Mediterranean Israeli Dust Experiment (MEIDEX), Shuttle Ozone Limb Sounding Experiment (SOLSE-2), Student Tracked Atmospheric Research Satellite for Heuristic International Networking Experiment (STARSHINE), Critical Viscosity of Xenon-2 (CVX-2), Solar Constant Experiment-3 (SOLOCON-3), Prototype Synchrotron Radiation Detector (PSRD), Low Power Transceiver (LPT), and Collisions Into Dust Experiment -2 (COLLIDE-2). STS-107 is scheduled to launch in July 2002
2002-01-10
KENNEDY SPACE CENTER, FLA. -- STS-107 Mission Specialist Kalpana Chawla scans paperwork for equipment at SPACEHAB, Cape Canaveral, Fla., during crew training. STS-107 is a research mission. The primary payload is the first flight of the SHI Research Double Module (SHI/RDM). The experiments range from material sciences to life sciences (many rats). Also part of the payload is the Fast Reaction Experiments Enabling Science, Technology, Applications and Research (FREESTAR) that incorporates eight high priority secondary attached shuttle experiments: Mediterranean Israeli Dust Experiment (MEIDEX), Shuttle Ozone Limb Sounding Experiment (SOLSE-2), Student Tracked Atmospheric Research Satellite for Heuristic International Networking Experiment (STARSHINE), Critical Viscosity of Xenon-2 (CVX-2), Solar Constant Experiment-3 (SOLOCON-3), Prototype Synchrotron Radiation Detector (PSRD), Low Power Transceiver (LPT), and Collisions Into Dust Experiment -2 (COLLIDE-2). STS-107 is scheduled to launch in July 2002
2001-12-19
KENNEDY SPACE CENTER, FLA. - STS-107 Payload Specialist Ilan Ramon, from Israel, pauses during an experiment at SPACEHAB, Cape Canaveral, Fla., to talk with Mission Specialist Laurel Clark. STS-107 is a research mission. The primary payload is the first flight of the SHI Research Double Module (SHI/RDM). The experiments range from material sciences to life sciences (many rats). Also part of the payload is the Fast Reaction Experiments Enabling Science, Technology, Applications and Research (FREESTAR) that incorporates eight high priority secondary attached shuttle experiments: Mediterranean Israeli Dust Experiment (MEIDEX), Shuttle Ozone Limb Sounding Experiment (SOLSE-2), Student Tracked Atmospheric Research Satellite for Heuristic International Networking Experiment (STARSHINE), Critical Viscosity of Xenon-2 (CVX-2), Solar Constant Experiment-3 (SOLOCON-3), Prototype Synchrotron Radiation Detector (PSRD), Low Power Transceiver (LPT), and Collisions Into Dust Experiment -2 (COLLIDE-2). STS-107 is scheduled to launch in July 2002.
2001-12-19
KENNEDY SPACE CENTER, FLA. - At SPACEHAB, Cape Canaveral, Fla., members of the STS-107 crew familiarize themselves with experiments and equipment for the mission. Pointing at a piece of equipment (center) is Mission Specialist Laurel Clark . At right is Mission Specialist Kalpana Chawla. STS-107 is a research mission. The primary payload is the first flight of the SHI Research Double Module (SHI/RDM). The experiments range from material sciences to life sciences (many rats). Also part of the payload is the Fast Reaction Experiments Enabling Science, Technology, Applications and Research (FREESTAR) that incorporates eight high priority secondary attached shuttle experiments: Mediterranean Israeli Dust Experiment (MEIDEX), Shuttle Ozone Limb Sounding Experiment (SOLSE-2), Student Tracked Atmospheric Research Satellite for Heuristic International Networking Experiment (STARSHINE), Critical Viscosity of Xenon-2 (CVX-2), Solar Constant Experiment-3 (SOLOCON-3), Prototype Synchrotron Radiation Detector (PSRD), Low Power Transceiver (LPT), and Collisions Into Dust Experiment -2 (COLLIDE-2). STS-107 is scheduled to launch in July 2002
2001-12-19
KENNEDY SPACE CENTER, FLA. - - STS-107 Payload Specialist Ilan Ramon, from Israel, works on an experiment at SPACEHAB, Cape Canaveral, Fla. With him is Mission Specialist Laurel Clark. STS-107 is a research mission. The primary payload is the first flight of the SHI Research Double Module (SHI/RDM). The experiments range from material sciences to life sciences (many rats). Also part of the payload is the Fast Reaction Experiments Enabling Science, Technology, Applications and Research (FREESTAR) that incorporates eight high priority secondary attached shuttle experiments: Mediterranean Israeli Dust Experiment (MEIDEX), Shuttle Ozone Limb Sounding Experiment (SOLSE-2), Student Tracked Atmospheric Research Satellite for Heuristic International Networking Experiment (STARSHINE), Critical Viscosity of Xenon-2 (CVX-2), Solar Constant Experiment-3 (SOLOCON-3), Prototype Synchrotron Radiation Detector (PSRD), Low Power Transceiver (LPT), and Collisions Into Dust Experiment -2 (COLLIDE-2). STS-107 is scheduled to launch in July 2002
STS-107 Mission Specialist Kalpana Chawla at SPACEHAB during training
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- STS-107 Mission Specialist Kalpana Chawla scans paperwork for equipment at SPACEHAB, Cape Canaveral, Fla., during crew training. STS-107 is a research mission. The primary payload is the first flight of the SHI Research Double Module (SHI/RDM). The experiments range from material sciences to life sciences (many rats). Also part of the payload is the Fast Reaction Experiments Enabling Science, Technology, Applications and Research (FREESTAR) that incorporates eight high priority secondary attached shuttle experiments: Mediterranean Israeli Dust Experiment (MEIDEX), Shuttle Ozone Limb Sounding Experiment (SOLSE-2), Student Tracked Atmospheric Research Satellite for Heuristic International Networking Experiment (STARSHINE), Critical Viscosity of Xenon-2 (CVX-2), Solar Constant Experiment-3 (SOLOCON-3), Prototype Synchrotron Radiation Detector (PSRD), Low Power Transceiver (LPT), and Collisions Into Dust Experiment -2 (COLLIDE-2). STS-107 is scheduled to launch in July 2002
The effect of encoding conditions on learning in the prototype distortion task.
Lee, Jessica C; Livesey, Evan J
2017-06-01
The prototype distortion task demonstrates that it is possible to learn about a category of physically similar stimuli through mere observation. However, there have been few attempts to test whether different encoding conditions affect learning in this task. This study compared prototypicality gradients produced under incidental learning conditions in which participants performed a visual search task, with those produced under intentional learning conditions in which participants were required to memorize the stimuli. Experiment 1 showed that similar prototypicality gradients could be obtained for category endorsement and familiarity ratings, but also found (weaker) prototypicality gradients in the absence of exposure. In Experiments 2 and 3, memorization was found to strengthen prototypicality gradients in familiarity ratings in comparison to visual search, but there were no group differences in participants' ability to discriminate between novel and presented exemplars. Although the Search groups in Experiments 2 and 3 produced prototypicality gradients, they were no different in magnitude to those produced in the absence of stimulus exposure in Experiment 1, suggesting that incidental learning during visual search was not conducive to producing prototypicality gradients. This study suggests that learning in the prototype distortion task is not implicit in the sense of resulting automatically from exposure, is affected by the nature of encoding, and should be considered in light of potential learning-at-test effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Combs, S.K.; Foust, C.R.; Qualls, A.L.
Pellet injection systems for the next-generation fusion devices, such as the proposed International Thermonuclear Experimental Reactor (ITER), will require feed systems capable of providing a continuous supply of hydrogen ice at high throughputs. A straightforward concept in which multiple extruder units operate in tandem has been under development at the Oak Ridge National Laboratory. A prototype with three large-volume extruder units has been fabricated and tested in the laboratory. In experiments, it was found that each extruder could provide volumetric ice flow rates of up to {approximately}1.3 cm{sup 3}/s (for {approximately}10 s), which is sufficient for fueling fusion reactors atmore » the gigawatt power level. With the three extruders of the prototype operating in sequence, a steady rate of {approximately}0.33 cm{sup 3}/s was maintained for a duration of 1 h. Even steady-state rates approaching the full ITER design value ({approximately}1 cm{sup 3}/s) may be feasible with the prototype. However, additional extruder units (1{endash}3) would facilitate operations at the higher throughputs and reduce the duty cycle of each unit. The prototype can easily accommodate steady-state pellet fueling of present large tokamaks or other near-term plasma experiments.« less
Application of 3D printing to prototype and develop novel plant tissue culture systems.
Shukla, Mukund R; Singh, Amritpal S; Piunno, Kevin; Saxena, Praveen K; Jones, A Maxwell P
2017-01-01
Due to the complex process of designing and manufacturing new plant tissue culture vessels through conventional means there have been limited efforts to innovate improved designs. Further, development and availability of low cost, energy efficient LEDs of various spectra has made it a promising light source for plant growth in controlled environments. However, direct replacement of conventional lighting sources with LEDs does not address problems with uniformity, spectral control, or the challenges in conducting statistically valid experiments to assess the effects of light. Prototyping using 3D printing and LED based light sources could help overcome these limitations and lead to improved culture systems. A modular culture vessel design in which the fluence rate and spectrum of light are independently controlled was designed, prototyped using 3D printing, and evaluated for plant growth. This design is compatible with semi-solid and liquid based culture systems. Observations on morphology, chlorophyll content, and chlorophyll fluorescence based stress parameters from in vitro plants cultured under different light spectra with similar overall fluence rate indicated different responses in Nicotiana tabacum and Artemisia annua plantlets. This experiment validates the utility of 3D printing to design and test functional vessels and demonstrated that optimal light spectra for in vitro plant growth is species-specific. 3D printing was successfully used to prototype novel culture vessels with independently controlled variable fluence rate/spectra LED lighting. This system addresses several limitations associated with current lighting systems, providing more uniform lighting and allowing proper replication/randomization for experimental plant biology while increasing energy efficiency. A complete procedure including the design and prototyping of a culture vessel using 3D printing, commercial scale injection molding of the prototype, and conducting a properly replicated experiment are discussed. This open source design has the scope for further improvement and adaptation and demonstrates the power of 3D printing to improve the design of culture systems.
Prototypes and particulars: geometric and experience-dependent spatial categories.
Spencer, John P; Hund, Alycia M
2002-03-01
People use geometric cues to form spatial categories. This study investigated whether people also use the spatial distribution of exemplars. Adults pointed to remembered locations on a tabletop. In Experiment 1, a target was placed in each geometric category, and the location of targets was varied. Adults' responses were biased away from a midline category boundary toward geometric prototypes located at the centers of left and right categories. Experiment 2 showed that prototype effects were not influenced by cross-category interactions. In Experiment 3, subsets of targets were positioned at different locations within each category. When prototype effects were removed, there was a bias toward the center of the exemplar distribution, suggesting that common categorization processes operate across spatial and object domains.
Technology infusion of intellectual 3D printers-based prototyping of products into learning process
NASA Astrophysics Data System (ADS)
Boshhenko, T. V.; Chepur, P. V.
2018-03-01
The article considers the prospects for the technologies of intellectual design and prototyping applying 3D printers. It presents basic technologies of 3D printing, currently developed and released for construction. The experience of educational activities in the University to train students for the Academic Competitions on three-dimensional modeling and prototyping is described in the present article. Requirements for the prototyping implementation are given, allowing obtaining a positive effect from the technology infusion released for construction. The results of activities to train students for the Academic Competition are stated. It is established that the proposed approaches to the training of students have led to the highest score in the national contest in Novosibirsk when performing tasks for prototyping a stand for a cell phone and manufacturing the product on a 3D printer at the SLS technology, selective laser sintering. The conclusions about the possibilities and prospects of development of this direction in the industry in the entire country are drawn.
Rapid Prototyping 3D Model in Treatment of Pediatric Hip Dysplasia: A Case Report
Holt, Andrew M.; Starosolski, Zbigniew; Kan, J. Herman
2017-01-01
Abstract Background: Rapid prototyping is an emerging technology that integrates common medical imaging with specialized production mechanisms to create detailed anatomic replicas. 3D-printed models of musculoskeletal anatomy have already proven useful in orthopedics and their applications continue to expand. Case Description: We present the case of a 10 year-old female with Down syndrome and left acetabular dysplasia and chronic hip instability who underwent periacetabular osteotomy. A rapid prototyping 3D model was created to better understand the anatomy, counsel the family about the problem and the surgical procedure, as well as guide surgical technique. The intricate detail and size match of the model with the patient’s anatomy offered unparalleled, hands-on experience with the patient’s anatomy pre-operatively and improved surgical precision. Conclusions: Our experience with rapid prototyping confirmed its ability to enhance orthopedic care by improving the surgeon’s ability to understand complex anatomy. Additionally, we report a new application utilizing intraoperative fluoroscopic comparison of the model and patient to ensure surgical precision and minimize the risk of complications. This technique could be used in other challenging cases. The increasing availability of rapid prototyping welcomes further use in all areas of orthopedics. PMID:28852351
Rapid Prototyping 3D Model in Treatment of Pediatric Hip Dysplasia: A Case Report.
Holt, Andrew M; Starosolski, Zbigniew; Kan, J Herman; Rosenfeld, Scott B
2017-01-01
Rapid prototyping is an emerging technology that integrates common medical imaging with specialized production mechanisms to create detailed anatomic replicas. 3D-printed models of musculoskeletal anatomy have already proven useful in orthopedics and their applications continue to expand. We present the case of a 10 year-old female with Down syndrome and left acetabular dysplasia and chronic hip instability who underwent periacetabular osteotomy. A rapid prototyping 3D model was created to better understand the anatomy, counsel the family about the problem and the surgical procedure, as well as guide surgical technique. The intricate detail and size match of the model with the patient's anatomy offered unparalleled, hands-on experience with the patient's anatomy pre-operatively and improved surgical precision. Our experience with rapid prototyping confirmed its ability to enhance orthopedic care by improving the surgeon's ability to understand complex anatomy. Additionally, we report a new application utilizing intraoperative fluoroscopic comparison of the model and patient to ensure surgical precision and minimize the risk of complications. This technique could be used in other challenging cases. The increasing availability of rapid prototyping welcomes further use in all areas of orthopedics.
Neves, R C; Stokol, T; Bach, K D; McArt, J A A
2018-02-01
The objective of this study was to assess an optimized ion-selective electrode Ca-module prototype as a potential cow-side device for ionized Ca (iCa) measurements in bovine blood. A linearity experiment showed no deviation from linearity over a range of iCa concentrations compared with a commercial point-of-care (POC) device commonly used in the field (POC VS ; VetScan i-STAT, Abaxis North America, Union City, CA) and a laboratory gold standard benchtop blood-gas analyzer [reference analyzer (RA); ABL-800 FLEX, Radiometer Medical, Copenhagen, Denmark]. Coefficient of variation on 3 samples with high, within-range, and low iCa concentrations ranged from 1.0 to 3.9% for the prototype. A follow-up validation experiment was performed, in which our objectives were to (1) assess the performance of the prototype cow-side against the POC VS (farm gold-standard) using fresh non-anticoagulated whole-blood samples; (2) assess the performance of the prototype and the POC VS against the RA in a diagnostic laboratory using blood collected in a heparin-balanced syringe; and (3) assess the agreement of the prototype and POC VS on-farm (fresh non-anticoagulated whole blood) against the RA on heparin-balanced blood. Finally, sensitivity and specificity of the results obtained by the prototype and the POC VS cow-side compared with the results obtained by the laboratory RA using 3 different iCa cut points for classification of subclinical hypocalcemia were calculated. A total of 101 periparturient Holstein cows from 3 dairy farms in New York State were used for the second experiment. Ionized Ca results from the prototype cow-side were, on average, 0.06 mmol/L higher than the POC VS . With heparin-balanced samples under laboratory conditions, the prototype and POC VS measured an average 0.04 mmol/L higher and lower, respectively, compared with the RA. Results from the prototype and POC VS cow-side were 0.01 mmol/L higher and 0.05 mmol/L lower, respectively, compared with results from the laboratory RA on heparinized blood. Sensitivity and specificity for the prototype and the POC VS under farm conditions at 3 potential subclinical hypocalcemia cut points were 100 and ≥93.5%, respectively. This novel ion-selective electrode Ca-module could become a rapid low-cost tool for assessing iCa cow-side, while qualitatively allowing classification of subclinical hypocalcemia on-farm. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
Preference for facial averageness: Evidence for a common mechanism in human and macaque infants
Damon, Fabrice; Méary, David; Quinn, Paul C.; Lee, Kang; Simpson, Elizabeth A.; Paukner, Annika; Suomi, Stephen J.; Pascalis, Olivier
2017-01-01
Human adults and infants show a preference for average faces, which could stem from a general processing mechanism and may be shared among primates. However, little is known about preference for facial averageness in monkeys. We used a comparative developmental approach and eye-tracking methodology to assess visual attention in human and macaque infants to faces naturally varying in their distance from a prototypical face. In Experiment 1, we examined the preference for faces relatively close to or far from the prototype in 12-month-old human infants with human adult female faces. Infants preferred faces closer to the average than faces farther from it. In Experiment 2, we measured the looking time of 3-month-old rhesus macaques (Macaca mulatta) viewing macaque faces varying in their distance from the prototype. Like human infants, macaque infants looked longer to faces closer to the average. In Experiments 3 and 4, both species were presented with unfamiliar categories of faces (i.e., macaque infants tested with adult macaque faces; human infants and adults tested with infant macaque faces) and showed no prototype preferences, suggesting that the prototypicality effect is experience-dependent. Overall, the findings suggest a common processing mechanism across species, leading to averageness preferences in primates. PMID:28406237
Conceptual knowledge in the interpretation of idioms.
Nayak, N P; Gibbs, R W
1990-09-01
The authors examined how people determine the contextual appropriateness of idioms. In Experiment 1, idioms referring to the same temporal stage of a conceptual prototype were judged to be more similar in meaning than idioms referring to different temporal stages. In Experiment 2, idioms in a prototypical temporal sequence were more meaningful than idioms in sentences that violated the temporal sequence. In Experiment 3, idioms referring to the same stage of a conceptual prototype were differentiable on the basis of conceptual information. The conceptual coherence between idioms and contexts facilitated the processing speed of idioms in Experiment 4. Experiment 5 showed that speakers can recover the underlying conceptual metaphors that link an idiom to its figurative meaning. Experiment 6 showed that the metaphoric information reflected in the lexical makeup of idioms also determined the metaphoric appropriateness of idioms in certain contexts.
User ratings of prosthetic usability and satisfaction in VA study to optimize DEKA arm.
Resnik, Linda; Borgia, Matthew
2014-01-01
The Department of Veterans Affairs study to optimize the DEKA Arm provided feedback to inform optimization of the gen 2 (second-generation) prototype and evaluate the gen 3 (third-generation) prototype. This article summarizes recommendations to improve gen 2 and reports satisfaction and usability ratings of gen 2 and gen 3. Data were collected from 39 subjects; 37 subjects were included in this analysis. Of the subjects, 24 were fit with gen 2 (8 radial configuration [RC], 6 humeral configuration [HC], and 10 shoulder configuration [SC]), 13 were fit with gen 3 (4 RC, 5 HC, and 4 SC), and 5 were fit with both. Usability and satisfaction were evaluated using the Trinity Amputation and Prosthesis Experience Scale (TAPES) and study-specific usability and satisfaction scales. Descriptive statistics were examined and prototypes compared using Wilcoxon rank-sum. Results were stratified by configuration level and outcomes compared by prototype. Satisfaction and usability were greater for gen 3 than gen 2. Overall TAPES scores were similar; however, scores of the TAPES aesthetic satisfaction subscale were higher for gen 3. Compared with gen 2 users, gen 3 users were more satisfied with appearance, grips, and doffing and rated overall usability higher. Features of gen 3, including weight, external cables and wires, hand covering, and fingernails, would benefit from further optimization.
Experiences with the AEROnet/PSCN ATM Prototype
NASA Technical Reports Server (NTRS)
Kurak, Richard S.; Lisotta, Anthony J.; McCabe, James D.; Nothaft, Alfred E.; Russell, Kelly R.; Lasinski, T. A. (Technical Monitor)
1995-01-01
This paper discusses the experience gained by the AEROnet/PSCN networking team in deploying a prototype Asynchronous Transfer Mode (ATM) based network as part of the wide-area network for the Numerical Aerodynamic Simulation (NAS) Program at NASA Ames Research Center. The objectives of this prototype were to test concepts in using ATM over wide-area Internet Protocol (IP) networks and measure end-to-end system performance. This testbed showed that end-to-end ATM over a DS3 reaches approximately 80% of the throughput achieved from a FDDI to DS3 network. The 20% reduction in through-put can be attributed to the overhead associated with running ATM. As a result, we conclude that if the loss in capacity due to ATM overhead is balanced by the reduction in cost of ATM services, as compared to dedicated circuits, then ATM can be a viable alternative.
Eriksson, J; Ek, A; Johansson, G
2000-03-01
A software prototype to support the planning process for adapting home and work environments for people with physical disabilities was designed and later evaluated. The prototype exploits low-cost three-dimensional (3-D) graphics products in the home computer market. The essential features of the prototype are: interactive rendering with optional hardware acceleration, interactive walk-throughs, direct manipulation tools for moving objects and measuring distances, and import of 3-D-objects from a library. A usability study was conducted, consisting of two test sessions (three weeks apart) and a final interview. The prototype was then tested and evaluated by representatives of future users: five occupational therapist students, and four persons with physical disability, with no previous experience of the prototype. Emphasis in the usability study was placed on the prototype's efficiency and learnability. We found that it is possible to realise a planning tool for environmental adaptations, both regarding usability and technical efficiency. The usability evaluation confirms our findings from previous case studies, regarding the relevance and positive attitude towards this kind of planning tool. Although the prototype was found to be satisfactorily efficient for the basic tasks, the paper presents several suggestions for improvement of future prototype versions.
Cooperating when "you" and "I" are treated fairly: the moderating role of leader prototypicality.
De Cremer, David; van Dijke, Marius; Mayer, David M
2010-11-01
We developed a model predicting that leaders are most effective in stimulating follower cooperation when they consistently treat all group members in a fair manner and are prototypical (i.e., representative of the group's values and norms). In support of this idea, we consistently found that group members cooperated most when prototypical leaders treated themselves as well as their coworkers fairly across a laboratory experiment and 3 cross-sectional field studies. These findings highlight the important role of others' fairness experiences and perceptions in influencing one's own reactions and also the role of leaders as representing the group's values and norms. We discuss implications for fairness theory and the leader prototypicality literature. (c) 2010 APA, all rights reserved.
Prototypes Are Key Heuristic Information in Insight Problem Solving
ERIC Educational Resources Information Center
Yang, Wenjing; Dietrich, Arne; Liu, Peiduo; Ming, Dan; Jin, Yule; Nusbaum, Howard C.; Qiu, Jiang; Zhang, Qinglin
2016-01-01
Evidence from a range of fields indicates that inventions are often inspired by drawing a parallel to solutions found in nature. However, the cognitive mechanism of this process is not well understood. The cognitive mechanism of heuristic prototype in scientific innovation was tested with 3 experiments. First, 84 historical accounts of important…
Kappanayil, Mahesh; Koneti, Nageshwara Rao; Kannan, Rajesh R; Kottayil, Brijesh P; Kumar, Krishna
2017-01-01
Three-dimensional. (3D) printing is an innovative manufacturing process that allows computer-assisted conversion of 3D imaging data into physical "printouts" Healthcare applications are currently in evolution. The objective of this study was to explore the feasibility and impact of using patient-specific 3D-printed cardiac prototypes derived from high-resolution medical imaging data (cardiac magnetic resonance imaging/computed tomography [MRI/CT]) on surgical decision-making and preoperative planning in selected cases of complex congenital heart diseases (CHDs). Five patients with complex CHD with previously unresolved management decisions were chosen. These included two patients with complex double-outlet right ventricle, two patients with criss-cross atrioventricular connections, and one patient with congenitally corrected transposition of great arteries with pulmonary atresia. Cardiac MRI was done for all patients, cardiac CT for one; specific surgical challenges were identified. Volumetric data were used to generate patient-specific 3D models. All cases were reviewed along with their 3D models, and the impact on surgical decision-making and preoperative planning was assessed. Accurate life-sized 3D cardiac prototypes were successfully created for all patients. The models enabled radically improved 3D understanding of anatomy, identification of specific technical challenges, and precise surgical planning. Augmentation of existing clinical and imaging data by 3D prototypes allowed successful execution of complex surgeries for all five patients, in accordance with the preoperative planning. 3D-printed cardiac prototypes can radically assist decision-making, planning, and safe execution of complex congenital heart surgery by improving understanding of 3D anatomy and allowing anticipation of technical challenges.
The prototype of the Micro Vertex Detector of the CBM Experiment
NASA Astrophysics Data System (ADS)
Koziel, Michal; Amar-Youcef, Samir; Bialas, Norbert; Deveaux, Michael; Fröhlich, Ingo; Li, Qiyan; Michel, Jan; Milanović, Borislav; Müntz, Christian; Neumann, Bertram; Schrader, Christoph; Stroth, Joachim; Tischler, Tobias; Weirich, Roland; Wiebusch, Michael
2013-12-01
The Compressed Baryonic Matter (CBM) Experiment is one of the core experiments of the future FAIR facility at Darmstadt, Germany. This fixed-target experiment will explore the phase diagram of strongly interacting matter in the regime of highest net baryon densities with numerous probes, among them open charm. Reconstructing those short lived particles requires a vacuum compatible Micro Vertex Detector (MVD) with unprecedented properties. Its sensor technology has to feature a spatial resolution of <5 μm, a non-ionizing radiation tolerance of >1013 neq/cm2, an ionizing radiation tolerance of >3 Mrad and a time resolution of a few 10 μs. The MVD-prototype project aimed to study the integration the CMOS Monolithic Active Pixel Sensors foreseen for the MVD into an ultra light (0.3% X0) and a vacuum compatible detector system based on a cooling support made of CVD-diamond.
Dimensional Precision Research of Wax Molding Rapid Prototyping based on Droplet Injection
NASA Astrophysics Data System (ADS)
Mingji, Huang; Geng, Wu; yan, Shan
2017-11-01
The traditional casting process is complex, the mold is essential products, mold quality directly affect the quality of the product. With the method of rapid prototyping 3D printing to produce mold prototype. The utility wax model has the advantages of high speed, low cost and complex structure. Using the orthogonal experiment as the main method, analysis each factors of size precision. The purpose is to obtain the optimal process parameters, to improve the dimensional accuracy of production based on droplet injection molding.
3D Printing Prototypes for Healthcare Professionals: Creating a Reciprocating Syringe.
Rothenberg, Steven; Abdullah, Selwan; Hirsch, Jeffrey
2017-10-01
3D printing (additive manufacturing) has been around since 1984, but interest in the technology has increased exponentially as it has become both accessible and inexpensive. The applications of the technology in healthcare are still being explored; however, initial forays have been encouraging. It has the potential to revolutionize the process of prototyping for healthcare professionals by democratizing the process and enhancing collaboration, making it cheaper to do iterative prototyping with little or no engineering experience. This case report details the creation of a multi-lumen reciprocating syringe with 3D printing. The product has been created and tested using a variety of publicly available resources. It provides a detailed overview of the approach and the framework required to create such a medical device. However, the implications of this report are much larger than this one product, and the fundamental ideas discussed here could be used for creating customized solutions for many healthcare problems.
Acceptance testing of the prototype electrometer for the SAMPIE flight experiment
NASA Technical Reports Server (NTRS)
Hillard, G. Barry
1992-01-01
The Solar Array Module Plasma Interaction Experiment (SAMPIE) has two key instruments at the heart of its data acquisition capability. One of these, the electrometer, is designed to measure both ion and electron current from most of the samples included in the experiment. The accuracy requirement, specified by the project's Principal Investigator, is for agreement within 10 percent with a calibrated laboratory instrument. Plasma chamber testing was performed to assess the capabilities of the prototype design. Agreement was determined to be within 2 percent for electron collection and within 3 percent for ion collection.
Experiment study on an inductive superconducting fault current limiter using no-insulation coils
NASA Astrophysics Data System (ADS)
Qiu, D.; Li, Z. Y.; Gu, F.; Huang, Z.; Zhao, A.; Hu, D.; Wei, B. G.; Huang, H.; Hong, Z.; Ryu, K.; Jin, Z.
2018-03-01
No-insulation (NI) coil made of 2 G high temperature superconducting (HTS) tapes has been widely used in DC magnet due to its excellent performance of engineering current density, thermal stability and mechanical strength. However, there are few AC power device using NI coil at present. In this paper, the NI coil is firstly applied into inductive superconducting fault current limiter (iSFCL). A two-winding structure air-core iSFCL prototype was fabricated, composed of a primary copper winding and a secondary no-insulation winding using 2 G HTS coated conductors. Firstly, in order to testify the feasibility to use NI coil as the secondary winding, the impedance variation of the prototype at different currents and different cycles was tested. The result shows that the impedance increases rapidly with the current rises. Then the iSFCL prototype was tested in a 40 V rms/ 3.3 kA peak short circuit experiment platform, both of the fault current limiting and recovery property of the iSFCL are discussed.
Velasco, Ignacio; Vahdani, Soheil; Ramos, Hector
2017-09-01
Three-dimensional (3D) printing is relatively a new technology with clinical applications, which enable us to create rapid accurate prototype of the selected anatomic region, making it possible to plan complex surgery and pre-bend hardware for individual surgical cases. This study aimed to express our experience with the use of medical rapid prototype (MRP) of the maxillofacial region created by desktop 3D printer and its application in maxillofacial reconstructive surgeries. Three patients with benign mandible tumors were included in this study after obtaining informed consent. All patient's maxillofacial CT scan data was processed by segmentation and isolation software and mandible MRP was printed using our desktop 3D printer. These models were used for preoperative surgical planning and prebending of the reconstruction plate. MRP created by desktop 3D printer is a cost-efficient, quick and easily produced appliance for the planning of reconstructive surgery. It can contribute in patient orientation and helping them in a better understanding of their condition and proposed surgical treatment. It helps surgeons for pre-operative planning in the resection or reconstruction cases and represent an excellent tool in academic setting for residents training. The pre-bended reconstruction plate based on MRP, resulted in decreased surgery time, cost and anesthesia risks on the patients. Key words: 3D printing, medical modeling, rapid prototype, mandibular reconstruction, ameloblastoma.
Clinical application of three-dimensional printing technology in craniofacial plastic surgery.
Choi, Jong Woo; Kim, Namkug
2015-05-01
Three-dimensional (3D) printing has been particularly widely adopted in medical fields. Application of the 3D printing technique has even been extended to bio-cell printing for 3D tissue/organ development, the creation of scaffolds for tissue engineering, and actual clinical application for various medical parts. Of various medical fields, craniofacial plastic surgery is one of areas that pioneered the use of the 3D printing concept. Rapid prototype technology was introduced in the 1990s to medicine via computer-aided design, computer-aided manufacturing. To investigate the current status of 3D printing technology and its clinical application, a systematic review of the literature was conducted. In addition, the benefits and possibilities of the clinical application of 3D printing in craniofacial surgery are reviewed, based on personal experiences with more than 500 craniofacial cases conducted using 3D printing tactile prototype models.
Clinical Application of Three-Dimensional Printing Technology in Craniofacial Plastic Surgery
Kim, Namkug
2015-01-01
Three-dimensional (3D) printing has been particularly widely adopted in medical fields. Application of the 3D printing technique has even been extended to bio-cell printing for 3D tissue/organ development, the creation of scaffolds for tissue engineering, and actual clinical application for various medical parts. Of various medical fields, craniofacial plastic surgery is one of areas that pioneered the use of the 3D printing concept. Rapid prototype technology was introduced in the 1990s to medicine via computer-aided design, computer-aided manufacturing. To investigate the current status of 3D printing technology and its clinical application, a systematic review of the literature was conducted. In addition, the benefits and possibilities of the clinical application of 3D printing in craniofacial surgery are reviewed, based on personal experiences with more than 500 craniofacial cases conducted using 3D printing tactile prototype models. PMID:26015880
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
NASA Astrophysics Data System (ADS)
Francis, K.; Repond, J.; Schlereth, J.; Smith, J.; Xia, L.; Baldolemar, E.; Li, J.; Park, S. T.; Sosebee, M.; White, A. P.; Yu, J.; Eigen, G.; Mikami, Y.; Watson, N. K.; Thomson, M. A.; Ward, D. R.; Benchekroun, D.; Hoummada, A.; Khoulaki, Y.; Apostolakis, J.; Dotti, A.; Folger, G.; Ivantchenko, V.; Ribon, A.; Uzhinskiy, V.; Cârloganu, C.; Gay, P.; Manen, S.; Royer, L.; Tytgat, M.; Zaganidis, N.; Blazey, G. C.; Dyshkant, A.; Lima, J. G. R.; Zutshi, V.; Hostachy, J.-Y.; Morin, L.; Cornett, U.; David, D.; Ebrahimi, A.; Falley, G.; Gadow, K.; Göttlicher, P.; Günter, C.; Hartbrich, O.; Hermberg, B.; Karstensen, S.; Krivan, F.; Krüger, K.; Lutz, B.; Morozov, S.; Morgunov, V.; Neubüser, C.; Reinecke, M.; Sefkow, F.; Smirnov, P.; Terwort, M.; Garutti, E.; Laurien, S.; Lu, S.; Marchesini, I.; Matysek, M.; Ramilli, M.; Briggl, K.; Eckert, P.; Harion, T.; Schultz-Coulon, H.-Ch.; Shen, W.; Stamen, R.; Bilki, B.; Norbeck, E.; Northacker, D.; Onel, Y.; Wilson, G. W.; Kawagoe, K.; Sudo, Y.; Yoshioka, T.; Dauncey, P. D.; Wing, M.; Salvatore, F.; Cortina Gil, E.; Mannai, S.; Baulieu, G.; Calabria, P.; Caponetto, L.; Combaret, C.; Della Negra, R.; Grenier, G.; Han, R.; Ianigro, J.-C.; Kieffer, R.; Laktineh, I.; Lumb, N.; Mathez, H.; Mirabito, L.; Petrukhin, A.; Steen, A.; Tromeur, W.; Vander Donckt, M.; Zoccarato, Y.; Calvo Alamillo, E.; Fouz, M.-C.; Puerta-Pelayo, J.; Corriveau, F.; Bobchenko, B.; Chadeeva, M.; Danilov, M.; Epifantsev, A.; Markin, O.; Mizuk, R.; Novikov, E.; Popov, V.; Rusinov, V.; Tarkovsky, E.; Besson, D.; Buzhan, P.; Ilyin, A.; Kantserov, V.; Kaplin, V.; Karakash, A.; Popova, E.; Tikhomirov, V.; Kiesling, C.; Seidel, K.; Simon, F.; Soldner, C.; Weuste, L.; Amjad, M. S.; Bonis, J.; Callier, S.; Conforti di Lorenzo, S.; Cornebise, P.; Doublet, Ph.; Dulucq, F.; Fleury, J.; Frisson, T.; van der Kolk, N.; Li, H.; Martin-Chassard, G.; Richard, F.; de la Taille, Ch.; Pöschl, R.; Raux, L.; Rouëné, J.; Seguin-Moreau, N.; Anduze, M.; Balagura, V.; Boudry, V.; Brient, J.-C.; Cornat, R.; Frotin, M.; Gastaldi, F.; Guliyev, E.; Haddad, Y.; Magniette, F.; Musat, G.; Ruan, M.; Tran, T. H.; Videau, H.; Bulanek, B.; Zacek, J.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Ruzicka, P.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; Belhorma, B.; Ghazlane, H.; Kotera, K.; Ono, H.; Takeshita, T.; Uozumi, S.; Jeans, D.; Chang, S.; Khan, A.; Kim, D. H.; Kong, D. J.; Oh, Y. D.; Götze, M.; Sauer, J.; Weber, S.; Zeitnitz, C.
2014-11-01
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45×10×3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. A number of possible design improvements were identified, which should be implemented in a future detector of this type. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.
Influencing Gameplay in Support of Early Synthetic Prototyping Studies
2016-06-01
Synthetic Prototyping, acquisition, video games, crowdsourcing, Engineering Resilient Systems, science and technology, game environment 15. NUMBER OF...even though he did not play video games for entertainment, he would find time to participate in ESP (Vogt, Megiveron, & Smith, 2015). Meckler’s...reward used in video games: 1) score systems, 2) experience points, 3) item granting, 4) collectible resources, 5) achievement systems, 6) feedback
Innovative Technology Reduces Power Plant Emissions - Commercialization Success
NASA Technical Reports Server (NTRS)
Parrish, Clyde
2004-01-01
Emission control system development includes: (1) Development of new oxidizer scrubber system to eliminate NOx waste and produce fertilizer (2) Technology licensed and a 1 to 3 MWatt-scale prototype installed on. power plant (3) Development of method to oxidize NO. to N02 (4) Experience gained from licensing NASA technology
Dhir, Vinay; Itoi, Takao; Fockens, Paul; Perez-Miranda, Manuel; Khashab, Mouen A; Seo, Dong Wan; Yang, Ai Ming; Lawrence, Khek Yu; Maydeo, Amit
2015-02-01
EUS-guided biliary drainage (EUS-BD) has emerged as an alternative rescue method in patients with failed ERCP. Opportunities for teaching and training are limited because of a low case volume at most centers. To evaluate a stereolithography/3-dimensional (3D) printing bile duct prototype for teaching and training in EUS-BD. Prospective observational feasibility study. Tertiary referral center. Twenty endosonographers attending an interventional EUS workshop. A prototype of a dilated biliary system was prepared by computer-aided design and 3D printing. The study participants performed guidewire manipulation and EUS-BD procedures (antegrade procedure and/or choledochoduodenostomy) on the prototype. Participants were scored with the device on a scale of 1 to 5 via a questionnaire. Participants' success rate for various steps of the EUS-BD procedure was noted. Subjective and objective evaluation of the prototype regarding its overall applicability, quality of radiographic and EUS images, and 4 steps of EUS-BD procedure (needle puncture, guidewire manipulation, tract dilation, stent placement). Fifteen participants returned the questionnaire, and 10 completed all 4 steps of EUS-BD. The median score for overall utility was 4, whereas that for EUS and US views was 5. Participants with experience in performing more than 20 EUS-BD procedures scored the prototype significantly lower for stent placement (P = .013) and equivalent for needle puncture, tract dilation, and wire manipulation. The success rate of various steps was 100% for needle puncture and tract dilation, 82.35% for wire manipulation, and 80% for stent placement. The mean overall procedure time was 18 minutes. Small number of participants. The 3D printing bile duct prototype appears suitable for teaching of and training in the various steps of EUS-BD. Further studies are required to elucidate its role. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Human Factors Experiments for Data Link : Interim Report No. 3
DOT National Transportation Integrated Search
1973-08-01
The results of three experiments involving eight FAA NAFEC test pilots are reported. Section I describes the evaluation of four prototype Data Link displays in a GAT-1 simulator. While there was lack of agreement among the pilots as to the relative m...
Performance of prototype high-flow inhalable dust sampler in a livestock production facility.
Anthony, T Renée; Cai, Changjie; Mehaffy, John; Sleeth, Darrah; Volckens, John
2017-05-01
A high-flow inhalable sampler, designed for operational flow rates up to 10 L/min using computer simulations and examined in wind tunnel experiments, was evaluated in the field. This prototype sampler was deployed in collocation with an IOM (the benchmark standard sampler) in a swine farrowing building to examine the sampling performance for assessing concentrations of inhalable particulate mass and endotoxin. Paired samplers were deployed for 24 hr on 19 days over a 3-month period. On each sampling day, the paired samplers were deployed at three fixed locations and data were analyzed to identify agreement and to examine systematic biases between concentrations measured by these samplers. Thirty-six paired gravimetric samples were analyzed; insignificant, unsubstantial differences between concentrations were identified between the two samplers (p = 0.16; mean difference 0.03 mg/m 3 ). Forty-four paired samples were available for endotoxin analysis, and a significant (p = 0.001) difference in endotoxin concentration was identified: the prototype sampler, on average, had 120 EU/m 3 more endotoxin than did the IOM samples. Since the same gravimetric samples were analyzed for endotoxin content, the endotoxin difference is likely attributable to differences in endotoxin extraction. The prototype's disposable thin-film polycarbonate capsule was included with the filter in the 1-hr extraction procedure while the internal plastic cassette of the IOM required a rinse procedure that is susceptible to dust losses. Endotoxin concentrations measured with standard plastic IOM inserts that follow this rinsing procedure may underestimate the true endotoxin exposure concentrations. The maximum concentrations in the study (1.55 mg/m 3 gravimetric, 2328 EU/m 3 endotoxin) were lower than other agricultural or industrial environments. Future work should explore the performance of the prototype sampler in dustier environments, where concentrations approach particulates not otherwise specified (PNOS) limits of 10 mg/m 3 , including using the prototype as a personal sampler.
Vahdani, Soheil; Ramos, Hector
2017-01-01
Background Three-dimensional (3D) printing is relatively a new technology with clinical applications, which enable us to create rapid accurate prototype of the selected anatomic region, making it possible to plan complex surgery and pre-bend hardware for individual surgical cases. This study aimed to express our experience with the use of medical rapid prototype (MRP) of the maxillofacial region created by desktop 3D printer and its application in maxillofacial reconstructive surgeries. Material and Methods Three patients with benign mandible tumors were included in this study after obtaining informed consent. All patient’s maxillofacial CT scan data was processed by segmentation and isolation software and mandible MRP was printed using our desktop 3D printer. These models were used for preoperative surgical planning and prebending of the reconstruction plate. Conclusions MRP created by desktop 3D printer is a cost-efficient, quick and easily produced appliance for the planning of reconstructive surgery. It can contribute in patient orientation and helping them in a better understanding of their condition and proposed surgical treatment. It helps surgeons for pre-operative planning in the resection or reconstruction cases and represent an excellent tool in academic setting for residents training. The pre-bended reconstruction plate based on MRP, resulted in decreased surgery time, cost and anesthesia risks on the patients. Key words:3D printing, medical modeling, rapid prototype, mandibular reconstruction, ameloblastoma. PMID:29075412
In Vivo Determination of the Complex Elastic Moduli of Cetacean Head Tissue
2014-09-30
testing on Navy dolphins and stranded animals, for which permits and approvals have been obtained. 3 WORK COMPLETED System Design A prototype...chosen for the prototype system’s focal length. This would allow examination of brain tissue in a typical adult bottlenose dolphin , which is the...those observed in preliminary in vivo experiments (conducted under a separate effort) on two bottlenose dolphins and one beluga whale. System
Parallel PAB3D: Experiences with a Prototype in MPI
NASA Technical Reports Server (NTRS)
Guerinoni, Fabio; Abdol-Hamid, Khaled S.; Pao, S. Paul
1998-01-01
PAB3D is a three-dimensional Navier Stokes solver that has gained acceptance in the research and industrial communities. It takes as computational domain, a set disjoint blocks covering the physical domain. This is the first report on the implementation of PAB3D using the Message Passing Interface (MPI), a standard for parallel processing. We discuss briefly the characteristics of tile code and define a prototype for testing. The principal data structure used for communication is derived from preprocessing "patching". We describe a simple interface (COMMSYS) for MPI communication, and some general techniques likely to be encountered when working on problems of this nature. Last, we identify levels of improvement from the current version and outline future work.
Innovative Technology Reduces Power Plant Emissions-Commercialization Success
NASA Technical Reports Server (NTRS)
Parrish, Clyde; Chung, Landy
2004-01-01
Overview of emission control system development: (1) Development of new oxidizer scrubber system to eliminate NOx waste and produce fertilizer (2) Technology licensed and a 1 to 3 MWatt-scale prototype installed on power plant (3) Development of method to oxidize NO to NO2 (4) Experience gained from licensing NASA technology.
Confinement of nonneutral plasmas in the Prototype Ring Trap device
NASA Astrophysics Data System (ADS)
Himura, Haruhiko; Yoshida, Zensho; Nakashima, Chihiro; Morikawa, Junji; Kakuno, Hidekazu; Tahara, Shigeru; Shibayama, Norihisa
1999-12-01
Recently, an internal-ring device named Proto-RT (Prototype Ring Trap) was constructed at University of Tokyo, and experiments on the device have been intensively conducted. The main goal of Proto-RT is to explore an innovative method to attain a plasma equilibrium with extremely high-β (β>1) in a toroidal geometry using non-neutral condition. At the first series of the experiments, pure electron plasmas (ne˜1013m-3) have been successfully confined inside a separatrix. No disruption is so far observed. The confinement time of the electron plasmas is of order 0.1 ms for an X point configuration. The non-neutrality of Δne˜1013m-3 is already beyond the critical value which is required to produce an enough self-electric field E in non-neutral plasmas with n0˜1019m-3, causing a strong E×B flow thoroughly over the plasmas where the hydrodynamic pressure of the flow is predicted to balance with the thermal pressure of the plasmas.
Computational Analysis of a Prototype Martian Rotorcraft Experiment
NASA Technical Reports Server (NTRS)
Corfeld, Kelly J.; Strawn, Roger C.; Long, Lyle N.
2002-01-01
This paper presents Reynolds-averaged Navier-Stokes calculations for a prototype Martian rotorcraft. The computations are intended for comparison with an ongoing Mars rotor hover test at NASA Ames Research Center. These computational simulations present a new and challenging problem, since rotors that operate on Mars will experience a unique low Reynolds number and high Mach number environment. Computed results for the 3-D rotor differ substantially from 2-D sectional computations in that the 3-D results exhibit a stall delay phenomenon caused by rotational forces along the blade span. Computational results have yet to be compared to experimental data, but computed performance predictions match the experimental design goals fairly well. In addition, the computed results provide a high level of detail in the rotor wake and blade surface aerodynamics. These details provide an important supplement to the expected experimental performance data.
NASA Astrophysics Data System (ADS)
Adams, Matthew; Salgaonkar, Vasant; Jones, Peter; Plata, Juan; Chen, Henry; Pauly, Kim Butts; Sommer, Graham; Diederich, Chris
2017-03-01
An MR-guided endoluminal ultrasound applicator has been proposed for palliative and potential curative thermal therapy of pancreatic tumors. Minimally invasive ablation or hyperthermia treatment of pancreatic tumor tissue would be performed with the applicator positioned in the gastrointestinal (GI) lumen, and sparing of the luminal tissue would be achieved with a water-cooled balloon surrounding the ultrasound transducers. This approach offers the capability of conformal volumetric therapy for fast treatment times, with control over the 3D spatial deposition of energy. Prototype endoluminal ultrasound applicators have been fabricated using 3D printed fixtures that seat two 3.2 or 5.6 MHz planar or curvilinear transducers and contain channels for wiring and water flow. Spiral surface coils have been integrated onto the applicator body to allow for device localization and tracking for therapies performed under MR guidance. Heating experiments with a tissue-mimicking phantom in a 3T MR scanner were performed and demonstrated capability of the prototype to perform volumetric heating through duodenal luminal tissue under real-time PRF-based MR temperature imaging (MRTI). Additional experiments were performed in ex vivo pig carcasses with the applicator inserted into the esophagus and aimed towards liver or soft tissue surrounding the spine under MR guidance. These experiments verified the capacity of heating targets up to 20-25 mm from the GI tract. Active device tracking and automated prescription of imaging and temperature monitoring planes through the applicator were made possible by using Hadamard encoded tracking sequences to obtain the coordinates of the applicator tracking coils. The prototype applicators have been integrated with an MR software suite that performs real-time device tracking and temperature monitoring.
Developing the Systems Engineering Experience Accelerator (SEEA) Prototype and Roadmap
2011-05-31
Learning Model developed by Kolb , 1984. Figure 3: Learning Process: All Phases of Experiential Learning to be Engaged Profile building engages learners...simulation that will put the learner in an experiential , emotional state and effectively compress time and greatly accelerate the learning of a systems...Taxonomy ................................................................................. 9 2.3 Learning Theory Model and Learner Profile
Experimenting with a Superconducting Levitation Train
ERIC Educational Resources Information Center
Miryala, Santosh; Koblischka, M. R.
2014-01-01
The construction and operation of a prototype high-"Tc" superconducting train model is presented. The train is levitated by a melt-processed GdBa[subscript 2]Cu[subscript 3]O[subscript x] (Gd-123) superconducting material over a magnetic rail (track). The oval shaped track is constructed in S-N-S or PM3N configuration arranged on an iron…
Latest developments in a multi-user 3D display
NASA Astrophysics Data System (ADS)
Surman, Phil; Sexton, Ian; Bates, Richard; Lee, Wing Kai; Hopf, Klaus; Koukoulas, Triantaffilos
2005-11-01
De Montfort University, in conjunction with the Heinrich Hertz Institute, is developing a 3D display that is targeted specifically at the television market. It is capable of supplying 3D to several viewers who do not have to wear special glasses, and who are able to move freely over a room-sized area. The display consists of a single liquid crystal display that presents the same stereo pair to every viewer by employing spatial multiplexing. This presents a stereo pair on alternate pixel rows, with the conventional backlight replaced by novel steering optics controlled by the output of a head position tracker. Illumination is achieved using arrays of coaxial optical elements in conjunction with high-density white light emitting diode arrays. The operation of the steering and multiplexing optics in the prototype display are explained. The results obtained from a prototype built under the European Union-funded ATTEST 3D television project are described. The performance of this model was not optimum, but was sufficient to prove that the principle of operation is viable for a 3D television display. A second prototype, incorporating improvements based on experience gained, is currently under construction and this is also described. The prototype is capable of being developed into a display appropriate for a production model that will enable 3D television to come to market within the next ten years. With the current widespread usage of flat panel displays it is likely that customer preference will be for a hang-on-the-wall 3D display, and this challenge will be met by reconfiguring the optics and incorporating novel optical addressing techniques.
A high power, high density helicon discharge for the plasma wakefield accelerator experiment AWAKE
NASA Astrophysics Data System (ADS)
Buttenschön, B.; Fahrenkamp, N.; Grulke, O.
2018-07-01
A plasma cell prototype for the plasma wakefield accelerator experiment AWAKE based on a helicon discharge is presented. In the 1 m long prototype module a multiple antenna helicon discharge with an rf power density of 100 MW m‑3 is established. Based on the helicon dispersion relation, a linear scaling of plasma density with magnetic field is observed for rf frequencies above the lower hybrid frequency, ω LH ≤ 0.8ω rf. Density profiles are highest on the device axis and show shallow radial gradients, thus providing a relatively constant plasma density in the center over a radial range of Δr ≈ 10 mm with less than 10% variation. Peak plasma densities up to 7 × 1020 m‑3 are transiently achieved with a reproducibility that is sufficient for AWAKE. The results are in good agreement with power balance calculations.
Prototyping the graphical user interface for the operator of the Cherenkov Telescope Array
NASA Astrophysics Data System (ADS)
Sadeh, I.; Oya, I.; Schwarz, J.; Pietriga, E.
2016-07-01
The Cherenkov Telescope Array (CTA) is a planned gamma-ray observatory. CTA will incorporate about 100 imaging atmospheric Cherenkov telescopes (IACTs) at a Southern site, and about 20 in the North. Previous IACT experiments have used up to five telescopes. Subsequently, the design of a graphical user interface (GUI) for the operator of CTA involves new challenges. We present a GUI prototype, the concept for which is being developed in collaboration with experts from the field of Human-Computer Interaction (HCI). The prototype is based on Web technology; it incorporates a Python web server, Web Sockets and graphics generated with the d3.js Javascript library.
Design and Testing of the ARL Squeeze 4 Helical Flux Compression Generator
2013-06-01
armature makes contact. Centering the armature inside the coil was accomplished with three machined polyurethane (4 lb/ft3 Lastafoam)3 foam rings. A...after shrinking was ~1 mm thick. The explosive charge was comprised of a paper- reinforced phenolic cylinder filled with Comp-B explosive fill. The...backfilled with polyester resin. Foam rubber was placed between coil windings (figure 3a). All other subsequent experiments used a custom rapid-prototyped
“In vitro” Implantation Technique Based on 3D Printed Prosthetic Prototypes
NASA Astrophysics Data System (ADS)
Tarnita, D.; Boborelu, C.; Geonea, I.; Malciu, R.; Grigorie, L.; Tarnita, D. N.
2018-06-01
In this paper, Rapid Prototyping ZCorp 310 system, based on high-performance composite powder and on resin-high strength infiltration system and three-dimensional printing as a manufacturing method are used to obtain physical prototypes of orthopaedic implants and prototypes of complex functional prosthetic systems directly from the 3D CAD data. These prototypes are useful for in vitro experimental tests and measurements to optimize and obtain final physical prototypes. Using a new elbow prosthesis model prototype obtained by 3D printing, the surgical technique of implantation is established. Surgical implantation was performed on male corpse elbow joint.
NASA Astrophysics Data System (ADS)
Janzen, Kathryn Louise
Largely because of their resistance to magnetic fields, silicon photomultipliers (SiPMs) are being considered as the readout for the GlueX Barrel Calorimeter, a key component of the GlueX detector located immediately inside a 2.2 T superconducting solenoid. SiPMs with active area 1 x 1 mm2 have been investigated for use in other experiments, but detectors with larger active areas are required for the GlueX BCAL. This puts the GlueX collaboration in the unique position of being pioneers in the use of this frontend detection revolution by driving the technology for larger area sensors. SensL, a photonics research and development company in Ireland, has been collaborating with the University of Regina GlueX group to develop prototype large area SiPMs comprising 16 - 3x3 mm2 cells assembled in a close-packed matrix. Performance parameters of individual SensL 1x1 mm2 and 3x3 mm2 SiPMs along with prototype SensL SiPM arrays are tested, including current versus voltage characteristics, photon detection efficiency, and gain uniformity, in an effort to determine the suitability of these detectors to the GlueX BCAL readout.
The Accidental Transgressor: Morally-Relevant Theory of Mind
ERIC Educational Resources Information Center
Killen, Melanie; Mulvey, Kelly Lynn; Richardson, Cameron; Jampol, Noah; Woodward, Amanda
2011-01-01
To test young children's false belief theory of mind in a morally relevant context, two experiments were conducted. In Experiment 1, children (N=162) at 3.5, 5.5, and 7.5 years of age were administered three tasks: prototypic moral transgression task, false belief theory of mind task (ToM), and an "accidental transgressor" task, which measured a…
FOCIH: Form-Based Ontology Creation and Information Harvesting
NASA Astrophysics Data System (ADS)
Tao, Cui; Embley, David W.; Liddle, Stephen W.
Creating an ontology and populating it with data are both labor-intensive tasks requiring a high degree of expertise. Thus, scaling ontology creation and population to the size of the web in an effort to create a web of data—which some see as Web 3.0—is prohibitive. Can we find ways to streamline these tasks and lower the barrier enough to enable Web 3.0? Toward this end we offer a form-based approach to ontology creation that provides a way to create Web 3.0 ontologies without the need for specialized training. And we offer a way to semi-automatically harvest data from the current web of pages for a Web 3.0 ontology. In addition to harvesting information with respect to an ontology, the approach also annotates web pages and links facts in web pages to ontological concepts, resulting in a web of data superimposed over the web of pages. Experience with our prototype system shows that mappings between conceptual-model-based ontologies and forms are sufficient for creating the kind of ontologies needed for Web 3.0, and experiments with our prototype system show that automatic harvesting, automatic annotation, and automatic superimposition of a web of data over a web of pages work well.
Performance of Prototype High-Flow Inhalable Dust Sampler in a Livestock Production Facility
Anthony, T. Renée; Cai, Changjie; Mehaffy, John; Sleeth, Darrah; Volckens, John
2017-01-01
A high-flow inhalable sampler, designed for operational flow rates up to 10 L/min using computer simulations and examined in wind tunnel experiments, was evaluated in the field. This prototype sampler was deployed in collocation with an IOM (the benchmark standard sampler) in a swine farrowing building to examine the sampling performance for assessing concentrations of inhalable particulate mass and endotoxin. Paired samplers were deployed for 24-hours on 19 days over a three-month period. On each sampling day, the paired samplers were deployed at three fixed locations and data were analyzed to identify agreement and to examine systematic biases between concentrations measured by these samplers. Thirty-six paired gravimetric samples were analyzed; insignificant, unsubstantial differences between concentrations were identified between the two samplers (p=0.16; mean difference 0.03 mg/m3). Forty-four paired samples were available for endotoxin analysis, and a significant (p=0.001) difference in endotoxin concentration was identified: the prototype sampler, on average, had 120 EU/m3 more endotoxin than did the IOM samples. Since the same gravimetric samples were analyzed for endotoxin content, the endotoxin difference is likely attributable to differences in endotoxin extraction. The prototype’s disposable thin-film polycarbonate capsule was included with the filter in the 1-hour extraction procedure while the internal plastic cassette of the IOM required a rinse procedure that is susceptible to dust losses. Endotoxin concentrations measured with standard plastic IOM inserts that follow this rinsing procedure may underestimate the true endotoxin exposure concentrations. The maximum concentrations in the study (1.55 mg/m3 gravimetric, 2328 EU/m3 endotoxin) were lower than other agricultural or industrial environments. Future work should explore the performance of the prototype sampler in dustier environments, where concentrations approach particulates not otherwise specified (PNOS) limits of 10 mg/m3, including using the prototype as a personal sampler. PMID:27792469
Numerical aerodynamic simulation program long haul communications prototype
NASA Technical Reports Server (NTRS)
Cmaylo, Bohden K.; Foo, Lee
1987-01-01
This document is a report of the Numerical Aerodynamic Simulation (NAS) Long Haul Communications Prototype (LHCP). It describes the accomplishments of the LHCP group, presents the results from all LHCP experiments and testing activities, makes recommendations for present and future LHCP activities, and evaluates the remote workstation accesses from Langley Research Center, Lewis Research Center, and Colorado State University to Ames Research Center. The report is the final effort of the Long Haul (Wideband) Communications Prototype Plan (PT-1133-02-N00), 3 October 1985, which defined the requirements for the development, test, and operation of the LHCP network and was the plan used to evaluate the remote user bandwidth requirements for the Numerical Aerodynamic Simulation Processing System Network.
Construction and response of a highly granular scintillator-based electromagnetic calorimeter
NASA Astrophysics Data System (ADS)
Repond, J.; Xia, L.; Eigen, G.; Price, T.; Watson, N. K.; Winter, A.; Thomson, M. A.; Cârloganu, C.; Blazey, G. C.; Dyshkant, A.; Francis, K.; Zutshi, V.; Gadow, K.; Göttlicher, P.; Hartbrich, O.; Kotera, K.; Krivan, F.; Krüger, K.; Lu, S.; Lutz, B.; Reinecke, M.; Sefkow, F.; Sudo, Y.; Tran, H. L.; Kaplan, A.; Schultz-Coulon, H.-Ch.; Bilki, B.; Northacker, D.; Onel, Y.; Wilson, G. W.; Kawagoe, K.; Sekiya, I.; Suehara, T.; Yamashiro, H.; Yoshioka, T.; Alamillo, E. Calvo; Fouz, M. C.; Marin, J.; Navarrete, J.; Pelayo, J. Puerta; Verdugo, A.; Chadeeva, M.; Danilov, M.; Gabriel, M.; Goecke, P.; Graf, C.; Israeli, Y.; Kolk, N. Van Der; Simon, F.; Szalay, M.; Windel, H.; Bilokin, S.; Bonis, J.; Pöschl, R.; Thiebault, A.; Richard, F.; Zerwas, D.; Balagura, V.; Boudry, V.; Brient, J.-C.; Cornat, R.; Cvach, J.; Janata, M.; Kovalcuk, M.; Kvasnicka, J.; Polak, I.; Smolik, J.; Vrba, V.; Zalesak, J.; Zuklin, J.; Choi, W.; Kotera, K.; Nishiyama, M.; Sakuma, T.; Takeshita, T.; Tozuka, S.; Tsubokawa, T.; Uozumi, S.; Jeans, D.; Ootani, W.; Liu, L.; Chang, S.; Khan, A.; Kim, D. H.; Kong, D. J.; Oh, Y. D.; Ikuno, T.; Sudo, Y.; Takahashi, Y.; Götze, M.; Calice Collaboration
2018-04-01
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5 X0 depth and 180 × 180mm2 transverse dimensions was constructed, consisting of 2160 individually read out 10 × 45 × 3mm3 scintillator strips. This prototype was tested using electrons of 2-32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be (12 . 5 ± 0 . 1(stat.) ± 0 . 4(syst.)) % /√{ E [ GeV ] } ⊕(1.2 ± 0.1 (stat.)-0.7+0.6 (syst.)) %, where the uncertainties correspond to statistical and systematic sources, respectively.
Developing the Systems Engineering Experience Accelerator (SEEA) Prototype and Roadmap
2012-10-24
system attributes. These metrics track non-requirements performance, typically relate to production cost per unit, maintenance costs, training costs...immediately implement lessons learned from the training experience to the job, assuming the culture allows this. 1.3 MANAGEMENT PLAN/TECHNICAL OVERVIEW...resolving potential conflicts as they arise. Incrementally implement and continuously integrate capability in priority order, to ensure that final system
Tam, Matthew D B S; Laycock, Stephen D; Brown, James R I; Jakeways, Matthew
2013-12-01
To describe rapid prototyping or 3-dimensional (3D) printing of aneurysms with complex neck anatomy to facilitate endovascular aneurysm repair (EVAR). A 75-year-old man had a 6.6-cm infrarenal aortic aneurysm that appeared on computed tomographic angiography to have a sharp neck angulation of ~90°. However, although the computed tomography (CT) data were analyzed using centerline of flow, the true neck length and relations of the ostial origins were difficult to determine. No multidisciplinary consensus could be reached as to which stent-graft to use owing to these borderline features of the neck anatomy. Based on past experience with rapid prototyping technology, a decision was taken to print a model of the aneurysm to aid in visualization of the neck anatomy. The CT data were segmented, processed, and converted into a stereolithographic format representing the lumen as a 3D volume, from which a full-sized replica was printed within 24 hours. The model demonstrated that the neck was adequate for stent-graft repair using the Aorfix device. Rapid prototyping of aortic aneurysms is feasible and can aid decision making and device delivery. Further work is required to test the value of 3D replicas in planning procedures and their impact on procedure time, radiation dose, and procedure cost.
NASA Astrophysics Data System (ADS)
Fuad, Nurul Mohd; Zhu, Feng; Kaslin, Jan; Wlodkowic, Donald
2016-12-01
Despite the growing demand and numerous applications for the biomedical community, the developments in millifluidic devices for small model organisms are limited compared to other fields of biomicrofluidics. The main reasons for this stagnanation are difficulties in prototyping of millimeter scale and high aspect ratio devices needed for large metazoan organisms. Standard photolithography is in this context a time consuming procedure not easily adapted for fabrication of molds with vertical dimensions above 1 mm. Moreover, photolithography is still largely unattainable to a gross majority of biomedical laboratories willing to pursue custom development of their own chip-based platforms due to costs and need for dedicated clean room facilities. In this work, we present application of high-definition additive manufacturing systems for fabrication of 3D printed moulds used in soft lithography. Combination of 3D printing with PDMS replica molding appears to be an alternative for millifluidic systems that yields rapid and cost effective prototyping pipeline. We investigated the important aspects on both 3D printed moulds and PDMS replicas such as geometric accuracies and surface topology. Our results demonstrated that SLA technologies could be applied for rapid and accurate fabrication of millifluidic devices for trapping of millimetre-sized specimens such as living zebrafish larvae. We applied the new manufacturing method in a proof-of-concept prototype device capable of trapping and immobilizing living zebrafish larvae for recording heart rate variation in cardio-toxicity experiments.
Product management of making large pieces through Rapid Prototyping PolyJet® technology
NASA Astrophysics Data System (ADS)
Belgiu, G.; Cărăuşu, C.; Şerban, D.; Turc, C. G.
2017-08-01
The rapid prototyping process has already become a classic manufacturing process for parts and assemblies, either polymeric or metal parts. Besides the well-known advantages and disadvantages of the process, the use of 3D printers has a great inconvenience: the overall dimensions of the parts are limited. Obviously, there is a possibility to purchase a larger (and more expensive) 3D printer, but there are always larger pieces to be manufactured. One solution to this problem is the splitting of parts into several components that can be manufactured. The component parts can then be assembled in a single piece by known methods such as welding, gluing, screwing, etc. This paper shows our experience in making large pieces on the Strarasys® Objet24 printer, pieces larger than the tray sizes. The results obtained are valid for any 3D printer using the PolyJet® process.
Yang, Long; Shang, Xian-Wen; Fan, Jian-Nan; He, Zhi-Xu; Wang, Jian-Ji; Liu, Miao; Zhuang, Yong; Ye, Chuan
2016-01-01
To evaluate the effect of 3D printing in treating trimalleolar fractures and its roles in physician-patient communication, thirty patients with trimalleolar fractures were randomly divided into the 3D printing assisted-design operation group (Group A) and the no-3D printing assisted-design group (Group B). In Group A, 3D printing was used by the surgeons to produce a prototype of the actual fracture to guide the surgical treatment. All patients underwent open reduction and internal fixation. A questionnaire was designed for doctors and patients to verify the verisimilitude and effectiveness of the 3D-printed prototype. Meanwhile, the operation time and the intraoperative blood loss were compared between the two groups. The fracture prototypes were accurately printed, and the average overall score of the verisimilitude and effectiveness of the 3D-printed prototypes was relatively high. Both the operation time and the intraoperative blood loss in Group A were less than those in Group B (P < 0.05). Patient satisfaction using the 3D-printed prototype and the communication score were 9.3 ± 0.6 points. A 3D-printed prototype can faithfully reflect the anatomy of the fracture site; it can effectively help the doctors plan the operation and represent an effective tool for physician-patient communication.
Prototype detection unit for the CHIPS experiment
NASA Astrophysics Data System (ADS)
Pfützner, Maciej M.
2017-09-01
CHIPS (CHerenkov detectors In mine PitS) is an R&D project aiming to develop novel cost-effective neutrino detectors, focused on measuring the CP-violating neutrino mixing phase (δ CP). A single detector module, containing an enclosed volume of purified water, would be submerged in an existing lake, located in a neutrino beam. A staged approach is proposed with first detectors deployed in a flooded mine pit in Northern Minnesota, 7 mrad off-axis from the existing NuMI beam. A small proof-of-principle model (CHIPS-M) has already been tested and the first stage of a fully functional 10 kt module (CHIPS-10) is planned for 2018. One of the instruments submerged on board of CHIPS-M in autumn 2015 was a prototype detection unit, constructed at Nikhef. The unit contains hardware borrowed from the KM3NeT experiment, including 16 3 inch photomultiplier tubes and readout electronics. In addition to testing the mechanical design and data acquisition, the detector was used to record a large sample of cosmic ray muon events. The collected data is valuable for characterising the cosmic muon background and validating a Monte Carlo simulation used to optimise future designs. This paper introduces the CHIPS project, describes the design of the prototype unit, and presents the results of a preliminary data analysis.
Recognition memory for hue: Prototypical bias and the role of labeling.
Kelly, Laura Jane; Heit, Evan
2017-06-01
How does the concurrent use of language affect perception and memory for exemplars? Labels cue more general category information than a specific exemplar. Applying labels can affect the resulting memory for an exemplar. Here 3 alternative hypotheses are proposed for the role of labeling an exemplar at encoding: (a) labels distort memory toward the label prototype, (b) labels guide the level of specificity needed in the current context, and (c) labels direct attention to the label's referent among all possible features within a visual scene. University students were shown hues on object silhouettes that they either labeled with basic color categories, made preference judgments about, or indicated the animacy of its category. Experiments 1 and 2 established that there are response shifts toward the category prototype regardless of labeling, showing a pervasive influence of category knowledge on response bias. They also established an effect of labeling whereby labeling decreases the magnitude of shifts. Experiments 3 and 4 investigated the uniqueness and necessity of language in causing the decreased shift-neither of which proved to be the case. Overall, category-relative bias was pervasive and labeling appears to direct attention to the feature resulting in less biased memory. The results highlight that the context at encoding affects how memory is formed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
Du, Hui-Lin; Zhou, Zhao-Zhong; Sun, Ze-Qing; Ju, Bing-Feng; Xu, Shaoning; Sun, Anyu
2017-06-01
A new prototype non-contact profiler based on surface tracking has been specially developed. Surface tracking is carried out by a specially designed dual stage probe system with the aid of a four-Degree Of Freedom high-precision motion platform. The dual stage probe system keeps a short-range optical probe constantly tracking the surface by a self-developed voice coil motor servo, by which a wide measuring range of up to 10 mm is realized. The system performance evaluation including resolution, repeatability, and scanning speed proved the good capability of the new prototype non-contact profiler. To realize a full area covered 3D profile measurement of special-shaped optics within one scanning procedure, a signal intensity monitor integrated in the surface tracking controller is specially developed. In the experiment, a snip-single-corner-rectangular-shaped freeform surface was successfully measured over full area by the new non-contact profiler. This work provides an effective solution for 3D profile measurement of special-shaped optical surfaces over full reflecting area. Experimental results demonstrate that the proposed measuring system is of great significance in quality evaluation of optical surfaces.
Du, Hui-Lin; Zhou, Zhao-Zhong; Sun, Ze-Qing; Ju, Bing-Feng; Xu, Shaoning; Sun, Anyu
2017-06-01
A new prototype non-contact profiler based on surface tracking has been specially developed. Surface tracking is carried out by a specially designed dual stage probe system with the aid of a four-Degree Of Freedom high-precision motion platform. The dual stage probe system keeps a short-range optical probe constantly tracking the surface by a self-developed voice coil motor servo, by which a wide measuring range of up to 10 mm is realized. The system performance evaluation including resolution, repeatability, and scanning speed proved the good capability of the new prototype non-contact profiler. To realize a full area covered 3D profile measurement of special-shaped optics within one scanning procedure, a signal intensity monitor integrated in the surface tracking controller is specially developed. In the experiment, a snip-single-corner-rectangular-shaped freeform surface was successfully measured over full area by the new non-contact profiler. This work provides an effective solution for 3D profile measurement of special-shaped optical surfaces over full reflecting area. Experimental results demonstrate that the proposed measuring system is of great significance in quality evaluation of optical surfaces.
Micro Ion Mobility Sensor for In Situ Monitoring of Contaminated Groundwater
2012-01-01
volts per ampere V/cm volts per centimeter VC voltage compensation Vd drift velocity VOC volatile organic compounds Technical...experience in field test. 1.3 RESULTS Lab testing showed that a prototype sensor is capable of uniquely identifying 32 volatile organic compounds (VOC...3) water-loop, (4) water-to-vapor chamber, (5) permanent collector , (6) second-stage carrier gas inlet, (7) vapor-to-vapor chamber, (8) permanent
A strategic map for high-impact virtual experience design
NASA Astrophysics Data System (ADS)
Faste, Haakon; Bergamasco, Massimo
2009-02-01
We have employed methodologies of human centered design to inspire and guide the engineering of a definitive low-cost aesthetic multimodal experience intended to stimulate cultural growth. Using a combination of design research, trend analysis and the programming of immersive virtual 3D worlds, over 250 innovative concepts have been brainstormed, prototyped, evaluated and refined. These concepts have been used to create a strategic map for the development of highimpact virtual art experiences, the most promising of which have been incorporated into a multimodal environment programmed in the online interactive 3D platform XVR. A group of test users have evaluated the experience as it has evolved, using a multimodal interface with stereo vision, 3D audio and haptic feedback. This paper discusses the process, content, results, and impact on our engineering laboratory that this research has produced.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., GRANTS, OR COOPERATIVE AGREEMENTS FOR PROTOTYPE PROJECTS § 3.3 Applicability. This part applies to the... agreements for prototype projects that are directly relevant to weapons or weapon systems proposed to be...
OGO-1 and OGO-3 MIT plasma experiments S4903
NASA Technical Reports Server (NTRS)
1968-01-01
Plasma proton and plasma electron prototype and flight models were designed, fabricated, and tested. Ground support equipment for the models was also prepared. The flight models were launched aboard the first and third Orbiting Geophysical Observatories on 4 Sept. 1964 and 6 June 1966. These experiments have generally functioned in accordance with the design specifications and useful data are still being received.
Innovative Applications of Laser Scanning and Rapid Prototype Printing to Rock Breakdown Experiments
NASA Technical Reports Server (NTRS)
Bourke, Mary; Viles, Heather; Nicoll, Joe; Lyew-Ayee, Parris; Ghent, Rebecca; Holmlund, James
2008-01-01
We present the novel application of two technologies for use in rock breakdown experiments, i.e. close-range, ground-based 3D triangulation scanning and rapid prototype printing. These techniques aid analyses of form-process interactions across the range of scales relevant to breakdown (micron-m). This is achieved through (a) the creation of DEMs (which permit quantitative description and analysis of rock surface morphology and morphological change) and (b) the production of more realistically-shaped experimental blocks. We illustrate the use of these techniques, alongside appropriate data analysis routines, in experiments designed to investigate the persistence of fluvially-derived features in the face of subsequent wind abrasion and weathering. These techniques have a range of potential applications in experimental field and lab-based geomorphic studies beyond those specifically outlined here.
RF Metamaterials for Foliage Penetration (FOPEN) Application
2013-02-01
from LM TRACER program to develop those prototypes. Fig. 29 is an OSU prototype (#1, 7x7 array) fabricated and tested inside the ESL compact range...Fig. 29 shows the Prototype #1 under testing inside the ESL compact range. Figure 29 -Prototype #1 (7x7 Single-pol. Array) 3.2.3.1.2
Cryogenic Autogenous Pressurization Testing for Robotic Refueling Mission 3
NASA Technical Reports Server (NTRS)
Boyle, R.; DiPirro, M.; Tuttle, J.; Francis, J.; Mustafi, S.; Li, X.; Barfknecht, P.; DeLee, C. H.; McGuire, J.
2015-01-01
A wick-heater system has been selected for use to pressurize the Source Dewar of the Robotic Refueling Mission Phase 3 on-orbit cryogen transfer experiment payload for the International Space Station. Experimental results of autogenous pressurization of liquid argon and liquid nitrogen using a prototype wick-heater system are presented. The wick-heater generates gas to increase the pressure in the tank while maintaining a low bulk fluid temperature. Pressurization experiments were performed in 2013 to characterize the performance of the wick heater. This paper describes the experimental setup, pressurization results, and analytical model correlations.
Spurio, Rafael S; Soares, Adriana L; Carvalho, Rafael H; Silveira Junior, Vivaldo; Grespan, Moisés; Oba, Alexandre; Shimokomaki, Massami
2016-02-01
Throughout the chicken production chain, transport from farm to the commercial abattoir is one of the most critical sources of stress, particularly heat stress. The aim of this work was to describe the performance of a new prototype truck container designed to improve the microenvironment and reduce the incidence of pale, soft and exudative (PSE) meat and dead on arrival (DOA) occurrences. Experiments were carried out for four different conditions: regular and prototype truck, both with and without wetting loaded cages at the farm (for bird thermal stress relief) just before transporting. While there was no difference in the DOA index (P ≥ 0.05), the prototype truck caused a reduction (P < 0.05) in the occurrence of PSE meat by 66.3% and 49.6% with and without wetting, respectively. The results of this experiment clearly revealed a low-cost solution for transporting chickens that yields better animal welfare conditions and improves meat quality. © 2015 Japanese Society of Animal Science.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Racine, E; Hautvast, G; Binnekamp, D
Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery.more » The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry validation. Equipments and fundings for this project were provided by Philips Medical.« less
NASA Astrophysics Data System (ADS)
Mohtashami, Yahya; Luyen, Hung; Hagness, Susan C.; Behdad, Nader
2018-06-01
We present an investigation of a new class of microwave ablation (MWA) antennas capable of producing axially symmetric or asymmetric heating patterns. The antenna design is based on a dipole fed by a balanced parallel-wire transmission line. The angle and direction of the deployed dipole arms are used to control the heating pattern. We analyzed the specific absorption rate and temperature profiles using electromagnetic and thermal simulations. Two prototypes were fabricated and tested in ex vivo ablation experiments: one was designed to produce symmetric heating patterns and the other was designed to generate asymmetric heating patterns. Both fabricated prototypes exhibited good impedance matching and produced localized coagulation zones as predicted by the simulations. The prototype operating in porcine muscle created an ˜10 cm3 symmetric ablation zone after 10 min of ablation with a power level of 18 W. The prototype operating in egg white created an ˜4 cm3 asymmetric ablation zone with a directionality ratio of 40% after 5 min of ablation with a power level of 25 W. The proposed MWA antenna design shows promise for minimally invasive treatment of tumors in various clinical scenarios where, depending on the situation, a symmetric or an asymmetric heating pattern may be needed.
NASA Astrophysics Data System (ADS)
Tatchyn, Roman; Csonka, Paul
1986-01-01
The availability of undulators with submillimeter periods will profoundly affect the future development of soft x-ray sources and their attendant instrumentation. Outputs comparable to those of present-day conventional undulators, obtainable with much lower energy storage rings, is only one promising aspect of such devices. This paper critically examines some of the future prospects of such devices and describes the design and practical construction of a 1" long prototype consisting of 35 periods. A proposed experiment to test this device on a linac is described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lukhanin, Gennadiy; Biery, Kurt; Foulkes, Stephen
In the NO A experiment, the Detector Controls System (DCS) provides a method for controlling and monitoring important detector hardware and environmental parameters. It is essential for operating the detector and is required to have access to roughly 370,000 independent programmable channels via more than 11,600 physical devices. In this paper, we demonstrate an application of Control System Studio (CSS), developed by Oak Ridge National Laboratory, for the NO A experiment. The application of CSS for the DCS of the NO A experiment has been divided into three phases: (1) user requirements and concept prototype on a test-stand, (2) smallmore » scale deployment at the prototype Near Detector on the Surface, and (3) a larger scale deployment at the Far Detector. We also give an outline of the CSS integration with the NO A online software and the alarm handling logic for the Front-End electronics.« less
Hierarchical Task Network Prototyping In Unity3d
2016-06-01
visually debug. Here we present a solution for prototyping HTNs by extending an existing commercial implementation of Behavior Trees within the Unity3D game ...HTN, dynamic behaviors, behavior prototyping, agent-based simulation, entity-level combat model, game engine, discrete event simulation, virtual...commercial implementation of Behavior Trees within the Unity3D game engine prior to building the HTN in COMBATXXI. Existing HTNs were emulated within
C3I Rapid Prototype Investigation.
1986-01-01
feasibility of applying rapid K prototyping techniques to Air Force C3 1 system developments . This report presents the technical progress during the...computer tunctions. The cost to use each in terms of hardware, software, analysis, and needed further developments was assessed. Prototyping approaches were...acquirer, and developer are the ". basis for problems in C3I system developments . These problems destabilize r-. the requirements determination process
Design and operation of small biogas plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdel-Dayem, A.M.; Hamad, M.A.
1980-12-01
This paper concentrates on the experience gained from the adaptation of the Chinese biogas technology to rural areas of Egypt. Three different prototype digesters have been constructed. The first is a 10 M/sup 3/ rectangular digester of the water pressure type, the second is a 6 M/sup 3/ circular and shallow digester with domed roof and dished bottom. The third prototype unit with a capacity of 7 M/sup 3/ has been recently constructed. It combines the features of both plug flow and the Indian movable cap types. Provisions for solar heating of feed water, composting of effluent and attachments tomore » both latrine and animal shed were incorporated in the unit. The structural theory, design criteria, construction technique and cost estimation of the circular digester are described. Some operation and performance data of the circular digester are presented. This covers the effects of variation of ambient temperature on internal temperature, effects of temperature and pressure on the gas production rate and composition.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... CONTRACTS, GRANTS, OR COOPERATIVE AGREEMENTS FOR PROTOTYPE PROJECTS § 3.5 Appropriate use. In accordance... is participating to a significant extent in the prototype project; or (b) No nontraditional Defense contractor is participating to a significant extent in the prototype project, but at least one of the...
Assembly Tests of the First Nb 3 Sn Low-Beta Quadrupole Short Model for the Hi-Lumi LHC
Pan, H.; Felice, H.; Cheng, D. W.; ...
2016-01-18
In preparation for the high-luminosity upgrade of the Large Hadron Collider (LHC), the LHC Accelerator Research Program (LARP) in collaboration with CERN is pursuing the development of MQXF: a 150-mm-aperture high-field Nb3Sn quadrupole magnet. Moreover, the development phase starts with the fabrication and test of several short models (1.2-m magnetic length) and will continue with the development of several long prototypes. All of them are mechanically supported using a shell-based support structure, which has been extensively demonstrated on several R&D models within LARP. The first short model MQXFS-AT has been assembled at LBNL with coils fabricated by LARP and CERN.more » In our paper, we summarize the assembly process and show how it relies strongly on experience acquired during the LARP 120-mm-aperture HQ magnet series. We also present comparison between strain gauges data and finite-element model analysis. Finally, we present the implication of the MQXFS-AT experience on the design of the long prototype support structure.« less
Haptics using a smart material for eyes-free interaction in personal devices
NASA Astrophysics Data System (ADS)
Wang, Huihui; Lane, William Brian; Pappas, Devin; Duque, Bryam; Leong, John
2014-03-01
In this paper we present a prototype using a dry ionic polymer metal composite (IPMC) in interactive personal devices such as bracelet, necklace, pocket key chain or mobile devices for haptic interaction when audio or visual feedback is not possible or practical. This prototype interface is an electro-mechanical system that realizes a shape-changing haptic display for information communication. A dry IPMC will change its dimensions due to the electrostatic effect when an electrical potential is provided to them. The IPMC can operate at a lower voltage (less than 2.5V) which is compatible with requirements for personal electrical devices or mobile devices. The prototype consists of the addressable arrays of the IPMCs with different dimensions which are deformable to different shapes with proper handling or customization. 3D printing technology will be used to form supporting parts. Microcontrollers (about 3cm square) from DigiKey will be imbedded into this personal device. An Android based mobile APP will be developed to talk with microcontrollers to control IPMCs. When personal devices receive information signals, the original shape of the prototype will change to another shape related to the specific sender or types of information sources. This interactive prototype can simultaneously realize multiple methods for conveying haptic information such as dimension, force, and texture due to the flexible array design. We conduct several studies of user experience to explore how users' respond to shape change information.
Rapid prototyping for tissue-engineered bone scaffold by 3D printing and biocompatibility study.
He, Hui-Yu; Zhang, Jia-Yu; Mi, Xue; Hu, Yang; Gu, Xiao-Yu
2015-01-01
The prototyping of tissue-engineered bone scaffold (calcined goat spongy bone-biphasic ceramic composite/PVA gel) by 3D printing was performed, and the biocompatibility of the fabricated bone scaffold was studied. Pre-designed STL file was imported into the GXYZ303010-XYLE 3D printing system, and the tissue-engineered bone scaffold was fabricated by 3D printing using gel extrusion. Rabbit bone marrow stromal cells (BMSCs) were cultured in vitro and then inoculated to the sterilized bone scaffold obtained by 3D printing. The growth of rabbit BMSCs on the bone scaffold was observed under the scanning electron microscope (SEM). The effect of the tissue-engineered bone scaffold on the proliferation and differentiation of rabbit BMSCs using MTT assay. Universal testing machine was adopted to test the tensile strength of the bone scaffold. The leachate of the bone scaffold was prepared and injected into the New Zealand rabbits. Cytotoxicity test, acute toxicity test, pyrogenic test and intracutaneous stimulation test were performed to assess the biocompatibility of the bone scaffold. Bone scaffold manufactured by 3D printing had uniform pore size with the porosity of about 68.3%. The pores were well interconnected, and the bone scaffold showed excellent mechanical property. Rabbit BMSCs grew and proliferated on the surface of the bone scaffold after adherence. MTT assay indicated that the proliferation and differentiation of rabbit BMSCs on the bone scaffold did not differ significantly from that of the cells in the control. In vivo experiments proved that the bone scaffold fabricated by 3D printing had no acute toxicity, pyrogenic reaction or stimulation. Bone scaffold manufactured by 3D printing allows the rabbit BMSCs to adhere, grow and proliferate and exhibits excellent biomechanical property and high biocompatibility. 3D printing has a good application prospect in the prototyping of tissue-engineered bone scaffold.
Rapid prototyping for tissue-engineered bone scaffold by 3D printing and biocompatibility study
He, Hui-Yu; Zhang, Jia-Yu; Mi, Xue; Hu, Yang; Gu, Xiao-Yu
2015-01-01
The prototyping of tissue-engineered bone scaffold (calcined goat spongy bone-biphasic ceramic composite/PVA gel) by 3D printing was performed, and the biocompatibility of the fabricated bone scaffold was studied. Pre-designed STL file was imported into the GXYZ303010-XYLE 3D printing system, and the tissue-engineered bone scaffold was fabricated by 3D printing using gel extrusion. Rabbit bone marrow stromal cells (BMSCs) were cultured in vitro and then inoculated to the sterilized bone scaffold obtained by 3D printing. The growth of rabbit BMSCs on the bone scaffold was observed under the scanning electron microscope (SEM). The effect of the tissue-engineered bone scaffold on the proliferation and differentiation of rabbit BMSCs using MTT assay. Universal testing machine was adopted to test the tensile strength of the bone scaffold. The leachate of the bone scaffold was prepared and injected into the New Zealand rabbits. Cytotoxicity test, acute toxicity test, pyrogenic test and intracutaneous stimulation test were performed to assess the biocompatibility of the bone scaffold. Bone scaffold manufactured by 3D printing had uniform pore size with the porosity of about 68.3%. The pores were well interconnected, and the bone scaffold showed excellent mechanical property. Rabbit BMSCs grew and proliferated on the surface of the bone scaffold after adherence. MTT assay indicated that the proliferation and differentiation of rabbit BMSCs on the bone scaffold did not differ significantly from that of the cells in the control. In vivo experiments proved that the bone scaffold fabricated by 3D printing had no acute toxicity, pyrogenic reaction or stimulation. Bone scaffold manufactured by 3D printing allows the rabbit BMSCs to adhere, grow and proliferate and exhibits excellent biomechanical property and high biocompatibility. 3D printing has a good application prospect in the prototyping of tissue-engineered bone scaffold. PMID:26380018
32 CFR 3.6 - Limitations on cost-sharing.
Code of Federal Regulations, 2010 CFR
2010-07-01
... THAN CONTRACTS, GRANTS, OR COOPERATIVE AGREEMENTS FOR PROTOTYPE PROJECTS § 3.6 Limitations on cost... prototype project and cost-sharing is the reason for using OT authority, then the non-Federal amounts... the OT agreement becomes effective. Costs that were incurred for a prototype project by the business...
Analysis of dynamics and fit of diving suits
NASA Astrophysics Data System (ADS)
Mahnic Naglic, M.; Petrak, S.; Gersak, J.; Rolich, T.
2017-10-01
Paper presents research on dynamical behaviour and fit analysis of customised diving suits. Diving suits models are developed using the 3D flattening method, which enables the construction of a garment model directly on the 3D computer body model and separation of discrete 3D surfaces as well as transformation into 2D cutting parts. 3D body scanning of male and female test subjects was performed with the purpose of body measurements analysis in static and dynamic postures and processed body models were used for construction and simulation of diving suits prototypes. All necessary parameters, for 3D simulation were applied on obtained cutting parts, as well as parameters values for mechanical properties of neoprene material. Developed computer diving suits prototypes were used for stretch analysis on areas relevant for body dimensional changes according to dynamic anthropometrics. Garment pressures against the body in static and dynamic conditions was also analysed. Garments patterns for which the computer prototype verification was conducted were used for real prototype production. Real prototypes were also used for stretch and pressure analysis in static and dynamic conditions. Based on the obtained results, correlation analysis between body changes in dynamic positions and dynamic stress, determined on computer and real prototypes, was performed.
Bhatla, Puneet; Tretter, Justin T; Ludomirsky, Achi; Argilla, Michael; Latson, Larry A; Chakravarti, Sujata; Barker, Piers C; Yoo, Shi-Joon; McElhinney, Doff B; Wake, Nicole; Mosca, Ralph S
2017-01-01
Rapid prototyping facilitates comprehension of complex cardiac anatomy. However, determining when this additional information proves instrumental in patient management remains a challenge. We describe our experience with patient-specific anatomic models created using rapid prototyping from various imaging modalities, suggesting their utility in surgical and interventional planning in congenital heart disease (CHD). Virtual and physical 3-dimensional (3D) models were generated from CT or MRI data, using commercially available software for patients with complex muscular ventricular septal defects (CMVSD) and double-outlet right ventricle (DORV). Six patients with complex anatomy and uncertainty of the optimal management strategy were included in this study. The models were subsequently used to guide management decisions, and the outcomes reviewed. 3D models clearly demonstrated the complex intra-cardiac anatomy in all six patients and were utilized to guide management decisions. In the three patients with CMVSD, one underwent successful endovascular device closure following a prior failed attempt at transcatheter closure, and the other two underwent successful primary surgical closure with the aid of 3D models. In all three cases of DORV, the models provided better anatomic delineation and additional information that altered or confirmed the surgical plan. Patient-specific 3D heart models show promise in accurately defining intra-cardiac anatomy in CHD, specifically CMVSD and DORV. We believe these models improve understanding of the complex anatomical spatial relationships in these defects and provide additional insight for pre/intra-interventional management and surgical planning.
Three-Dimensional Printing of Vitrification Loop Prototypes for Aquatic Species.
Tiersch, Nolan J; Childress, William M; Tiersch, Terrence R
2018-05-16
Vitrification is a method of cryopreservation that freezes samples rapidly, while forming an amorphous solid ("glass"), typically in small (μL) volumes. The goal of this project was to create, by three-dimensional (3D) printing, open vitrification devices based on an elliptical loop that could be efficiently used and stored. Vitrification efforts can benefit from the application of 3D printing, and to begin integration of this technology, we addressed four main variables: thermoplastic filament type, loop length, loop height, and method of loading. Our objectives were to: (1) design vitrification loops with varied dimensions; (2) print prototype loops for testing; (3) evaluate loading methods for the devices; and (4) classify vitrification responses to multiple device configurations. The various configurations were designed digitally using 3D CAD (Computer Aided Design) software, and prototype devices were produced with MakerBot ® 3D printers. The thermoplastic filaments used to produce devices were acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA). Vitrification devices were characterized by the film volumes formed with different methods of loading (pipetting or submersion). Frozen films were classified to determine vitrification quality: zero (opaque, or abundant crystalline ice formation); one (translucent, or partial vitrification), or two (transparent, or substantial vitrification, glass). A published vitrification solution was used to conduct experiments. Loading by pipetting formed frozen films more reliably than by submersion, but submersion yielded fewer filling problems and was more rapid. The loop designs that yielded the highest levels of vitrification enabled rapid transfer of heat, and most often were characterized as being longer and consisting of fewer layers (height). 3D printing can assist standardization of vitrification methods and research, yet can also provide the ability to quickly design and fabricate custom devices when needed.
Kleyer, Arnd; Beyer, Laura; Simon, Christoph; Stemmler, Fabian; Englbrecht, Matthias; Beyer, Christian; Rech, Jürgen; Manger, Bernhard; Krönke, Gerhard; Schett, Georg; Hueber, Axel J
2017-02-10
Rheumatoid arthritis (RA) and psoriatic arthritis (PsA) result in severe joint destruction and functional disability if left untreated. We aim to develop tools that help patients with RA and PsA to understand and experience the impact of inflammatory joint disease on the integrity of their (juxta-articular) bone and increase adherence to medical treatment. In this study, we used high-resolution peripheral quantitative computed tomography (HR-pQCT) to develop 3D prototypes of patients' finger joints. HR-pQCT (XtremeCT, Scanco) measurements were performed in healthy individuals and patients with inflammatory joint disease, followed by a 3D print using the objet30 printer. Healthy participants (n = 10), and patients (n = 15 with RA and 15 with PsA) underwent a detailed, standardized interview with demonstration of printed joints. Utilizing HR-pQCT images of metacarpophalangeal (MCP) heads, high quality and exact 3D prints as prototypes were created. Erosions in different sizes and the trabecular network printed in detail were visualized, demonstrating structural reduction in arthritic vs. healthy bone. After demonstration of 3D prints (healthy vs. erosive joint, visual and haptic) 26/39 (66%) participants (including healthy volunteers) were deeply affected, often quoting "shock". Of the patients with RA and PsA, 13/15 (86%) and 11/15 (73%), respectively, stated that they would rethink their attitude to medication adherence. More importantly, 21/24 patients with RA or PsA (87.5%) expressed that they would have wished to see such 3D prints during their first disease-specific conversations. Using arthro-haptic 3D printed prototypes of joints may help to better understand the impact of inflammatory arthritides on bone integrity and long-term damage.
Herickhoff, Carl D; Light, Edward D; Bing, Kristin F; Mukundan, Srinivasan; Grant, Gerald A; Wolf, Patrick D; Smith, Stephen W
2009-04-01
In this study, we investigated the feasibility of an intracranial catheter transducer with dual-mode capability of real-time 3D (RT3D) imaging and ultrasound hyperthermia, for application in the visualization and treatment of tumors in the brain. Feasibility is demonstrated in two ways: first by using a 50-element linear array transducer (17 mm x 3.1 mm aperture) operating at 4.4 MHz with our Volumetrics diagnostic scanner and custom, electrical impedance-matching circuits to achieve a temperature rise over 4 degrees C in excised pork muscle, and second, by designing and constructing a 12 Fr, integrated matrix and linear-array catheter transducer prototype for combined RT3D imaging and heating capability. This dual-mode catheter incorporated 153 matrix array elements and 11 linear array elements diced on a 0.2 mm pitch, with a total aperture size of 8.4 mm x 2.3 mm. This 3.64 MHz array achieved a 3.5 degrees C in vitro temperature rise at a 2 cm focal distance in tissue-mimicking material. The dual-mode catheter prototype was compared with a Siemens 10 Fr AcuNav catheter as a gold standard in experiments assessing image quality and therapeutic potential and both probes were used in an in vivo canine brain model to image anatomical structures and color Doppler blood flow and to attempt in vivo heating.
Vibrotactile Compliance Feedback for Tangential Force Interaction.
Heo, Seongkook; Lee, Geehyuk
2017-01-01
This paper presents a method to generate a haptic illusion of compliance using a vibrotactile actuator when a tangential force is applied to a rigid surface. The novel method builds on a conceptual compliance model where a physical object moves on a textured surface in response to a tangential force. The method plays vibration patterns simulating friction-induced vibrations as an applied tangential force changes. We built a prototype consisting of a two-dimensional tangential force sensor and a surface transducer to test the effectiveness of the model. Participants in user experiments with the prototype perceived the rigid surface of the prototype as a moving, rubber-like plate. The main findings of the experiments are: 1) the perceived stiffness of a simulated material can be controlled by controlling the force-playback transfer function, 2) its perceptual properties such as softness and pleasantness can be controlled by changing friction grain parameters, and 3) the use of the vibrotactile compliance feedback reduces participants' workload including physical demand and frustration while performing a force repetition task.
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
Francis, K.; Repond, J.; Schlereth, J.; ...
2014-11-01
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45 × 10 × 3 mm³ plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. A number of possible design improvements were identified, which should be implemented in a future detector of thismore » type. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.« less
Effect of spine motion on mobility in quadruped running
NASA Astrophysics Data System (ADS)
Chen, Dongliang; Liu, Qi; Dong, Litao; Wang, Hong; Zhang, Qun
2014-11-01
Most of current running quadruped robots have similar construction: a stiff body and four compliant legs. Many researches have indicated that the stiff body without spine motion is a main factor in limitation of robots' mobility. Therefore, investigating spine motion is very important to build robots with better mobility. A planar quadruped robot is designed based on cheetahs' morphology. There is a spinal driving joint in the body of the robot. When the spinal driving joint acts, the robot has spine motion; otherwise, the robot has not spine motion. Six group prototype experiments with the robot are carried out to study the effect of spine motion on mobility. In each group, there are two comparative experiments: the spinal driving joint acts in one experiment but does not in the other experiment. The results of the prototype experiments indicate that the average speeds of the robot with spine motion are 8.7%-15.9% larger than those of the robot without spine motion. Furthermore, a simplified sagittal plane model of quadruped mammals is introduced. The simplified model also has a spinal driving joint. Using a similar process as the prototype experiments, six group simulation experiments with the simplified model are conducted. The results of the simulation experiments show that the maximum rear leg horizontal thrusts of the simplified mode with spine motion are 68.2%-71.3% larger than those of the simplified mode without spine motion. Hence, it is found that spine motion can increase the average running speed and the intrinsic reason of speed increase is the improvement of the maximum rear leg horizontal thrust.
NASA Astrophysics Data System (ADS)
Amend, P.; Pscherer, C.; Rechtenwald, T.; Frick, T.; Schmidt, M.
This paper presents experimental results of manufacturing MID-prototypes by means of SLS, laser structuring and metallization. Therefore common SLS powder (PA12) doped with laser structuring additives is used. First of all the influence of the additives on the characteristic temperatures of melting and crystallization is analyzed by means of DSC. Afterwards the sintering process is carried out and optimized by experiments. Finally the generated components are qualified regarding their density, mechanical properties and surface roughness. Especially the surface quality is important for the metallization process. Therefore surface finishing techniques are investigated.
Abraham, Jared D.; Moulton, Craig; Brown, Philip J.
2002-01-01
In October 2001, the U.S. Geological Survey conducted borehole radar surveys of an oil injection experiment at the Colorado School of Mines (CSM), in Golden Colorado using the prototype U.S. Geological Survey (USGS)-developed directional borehole radar system (DBOR). A explanation of the system can be found in Wright and others (2001). The USGS was invited to the CSM to deploy the prototype directional borehole radar system during an oil injection experiment conducted to investigate the applicability of radar to monitoring formation invasion from a horizontal borehole. This work was conducted by a student at the CSM and is summarized in Moita (2001). The purpose of this report is to release the data and to summarize the experiments conducted with the DBOR system. This report contains, (1) a description of the system as deployed in the experiments, (2) a description of the data collected and data parameters used, (3) a simple display of some of the data collected, and (4) a description of the DBOR data files.
3D laptop for defense applications
NASA Astrophysics Data System (ADS)
Edmondson, Richard; Chenault, David
2012-06-01
Polaris Sensor Technologies has developed numerous 3D display systems using a US Army patented approach. These displays have been developed as prototypes for handheld controllers for robotic systems and closed hatch driving, and as part of a TALON robot upgrade for 3D vision, providing depth perception for the operator for improved manipulation and hazard avoidance. In this paper we discuss the prototype rugged 3D laptop computer and its applications to defense missions. The prototype 3D laptop combines full temporal and spatial resolution display with the rugged Amrel laptop computer. The display is viewed through protective passive polarized eyewear, and allows combined 2D and 3D content. Uses include robot tele-operation with live 3D video or synthetically rendered scenery, mission planning and rehearsal, enhanced 3D data interpretation, and simulation.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., GRANTS, OR COOPERATIVE AGREEMENTS FOR PROTOTYPE PROJECTS § 3.1 Purpose. This part consolidates rules that..., or cooperative agreements in certain situations for prototype projects that are directly relevant to...
32 CFR 3.7 - Comptroller General access.
Code of Federal Regulations, 2010 CFR
2010-07-01
... THAN CONTRACTS, GRANTS, OR COOPERATIVE AGREEMENTS FOR PROTOTYPE PROJECTS § 3.7 Comptroller General access. (a) A clause must be included in solicitations and agreements for prototype projects awarded...
Phase aided 3D imaging and modeling: dedicated systems and case studies
NASA Astrophysics Data System (ADS)
Yin, Yongkai; He, Dong; Liu, Zeyi; Liu, Xiaoli; Peng, Xiang
2014-05-01
Dedicated prototype systems for 3D imaging and modeling (3DIM) are presented. The 3D imaging systems are based on the principle of phase-aided active stereo, which have been developed in our laboratory over the past few years. The reported 3D imaging prototypes range from single 3D sensor to a kind of optical measurement network composed of multiple node 3D-sensors. To enable these 3D imaging systems, we briefly discuss the corresponding calibration techniques for both single sensor and multi-sensor optical measurement network, allowing good performance of the 3DIM prototype systems in terms of measurement accuracy and repeatability. Furthermore, two case studies including the generation of high quality color model of movable cultural heritage and photo booth from body scanning are presented to demonstrate our approach.
Canstein, C; Cachot, P; Faust, A; Stalder, A F; Bock, J; Frydrychowicz, A; Küffer, J; Hennig, J; Markl, M
2008-03-01
The knowledge of local vascular anatomy and function in the human body is of high interest for the diagnosis and treatment of cardiovascular disease. A comprehensive analysis of the hemodynamics in the thoracic aorta is presented based on the integration of flow-sensitive 4D MRI with state-of-the-art rapid prototyping technology and computational fluid dynamics (CFD). Rapid prototyping was used to transform aortic geometries as measured by contrast-enhanced MR angiography into realistic vascular models with large anatomical coverage. Integration into a flow circuit with patient-specific pulsatile in-flow conditions and application of flow-sensitive 4D MRI permitted detailed analysis of local and global 3D flow dynamics in a realistic vascular geometry. Visualization of characteristic 3D flow patterns and quantitative comparisons of the in vitro experiments with in vivo data and CFD simulations in identical vascular geometries were performed to evaluate the accuracy of vascular model systems. The results indicate the potential of such patient-specific model systems for detailed experimental simulation of realistic vascular hemodynamics. Further studies are warranted to examine the influence of refined boundary conditions of the human circulatory system such as fluid-wall interaction and their effect on normal and pathological blood flow characteristics associated with vascular geometry. (c) 2008 Wiley-Liss, Inc.
Mirbozorgi, S Abdollah; Bahrami, Hadi; Sawan, Mohamad; Gosselin, Benoit
2016-04-01
This paper presents a novel experimental chamber with uniform wireless power distribution in 3D for enabling long-term biomedical experiments with small freely moving animal subjects. The implemented power transmission chamber prototype is based on arrays of parallel resonators and multicoil inductive links, to form a novel and highly efficient wireless power transmission system. The power transmitter unit includes several identical resonators enclosed in a scalable array of overlapping square coils which are connected in parallel to provide uniform power distribution along x and y. Moreover, the proposed chamber uses two arrays of primary resonators, facing each other, and connected in parallel to achieve uniform power distribution along the z axis. Each surface includes 9 overlapped coils connected in parallel and implemented into two layers of FR4 printed circuit board. The chamber features a natural power localization mechanism, which simplifies its implementation and ease its operation by avoiding the need for active detection and control mechanisms. A single power surface based on the proposed approach can provide a power transfer efficiency (PTE) of 69% and a power delivered to the load (PDL) of 120 mW, for a separation distance of 4 cm, whereas the complete chamber prototype provides a uniform PTE of 59% and a PDL of 100 mW in 3D, everywhere inside the chamber with a size of 27×27×16 cm(3).
TeCo3D: a 3D telecooperation application based on VRML and Java
NASA Astrophysics Data System (ADS)
Mauve, Martin
1998-12-01
In this paper we present a method for sharing collaboration- unaware VRML content, e.g. 3D models which were not specifically developed for use in a distributed environment. This functionality is an essential requirement for the inclusion of arbitrary VRML content, as generated by standard CAD or animation software, into teleconferencing sessions. We have developed a 3D TeleCooperation (TeCo3D) prototype to demonstrate the feasibility of our approach. The basic services provided by the prototype are the distribution of cooperation unaware VRML content, the sharing of user interactions, and the joint viewing of the content. In order to achieve maximum portability, the prototype was developed completely in Java. This paper presents general aspects of sharing VRML content as well as the concepts, the architecture and the services of the TeCo3D prototype. Our approach relies on existing VRML browsers as the VRML presentation and execution engines while reliable multicast is used as the means of communication to provide for scalability.
Fujii, Masahiro; Sugita, Naohiko; Ishimaru, Tetsuya; Iwanaka, Tadashi; Mitsuishi, Mamoru
2013-02-01
The objective of our research was to design and develop a novel needle driver with multiple degrees of freedom (DOFs) for pediatric laparoscopic surgery. Pediatric laparoscopic surgery has many advantages for patients, but the difficulty of the operation is increased due to many restrictions. For example, the motion of the needle driver is restricted by the insertion points, and the operation workspace is smaller in children than in adults. A needle driver with 3 DOFs and a 3.5-mm diameter is proposed and implemented in this study. Grasping DOF is achieved using a piston mechanism actuated by a wire. Deflection and rotation DOFs are actuated by gears. Experiments were conducted to evaluate the workspace and ligation force, and the results confirmed that the needle driver meets all the necessary requirements. Finally, a first reaction of a pediatric surgeon on the suturing and ligaturing capabilities of the prototype is reported. A multi-DOF needle driver with a new mechanism was proposed for pediatric laparoscopic surgery and a first prototype was developed. It is expected that further elaboration of the developed first prototype of the needle driver may contribute to the advancement of pediatric laparoscopic surgery.
Herickhoff, Carl D.; Light, Edward D.; Bing, Kristin F.; Mukundan, Srinivasan; Grant, Gerald A.; Wolf, Patrick D.; Smith, Stephen W.
2010-01-01
In this study, we investigated the feasibility of an intracranial catheter transducer with dual-mode capability of real-time 3D (RT3D) imaging and ultrasound hyperthermia, for application in the visualization and treatment of tumors in the brain. Feasibility is demonstrated in two ways: first by using a 50-element linear array transducer (17 mm × 3.1 mm aperture) operating at 4.4 MHz with our Volumetrics diagnostic scanner and custom electrical impedance matching circuits to achieve a temperature rise over 4°C in excised pork muscle, and second by designing and constructing a 12 Fr, integrated matrix and linear array catheter transducer prototype for combined RT3D imaging and heating capability. This dual-mode catheter incorporated 153 matrix array elements and 11 linear array elements diced on a 0.2 mm pitch, with a total aperture size of 8.4 mm × 2.3 mm. This array achieved a 3.5°C in vitro temperature rise at a 2 cm focal distance in tissue-mimicking material. The dual-mode catheter prototype was compared with a Siemens 10 Fr AcuNav™ catheter as a gold standard in experiments assessing image quality and therapeutic potential, and both probes were used in a canine brain model to image anatomical structures and color Doppler blood flow and to attempt in vivo heating. PMID:19630251
ERIC Educational Resources Information Center
United Nations Educational, Scientific, and Cultural Organization, Bangkok (Thailand). Regional Office for Education in Asia and the Pacific.
One of the main products of the Regional Workshop for the Development of Packages of Adequate Learning Requirements in Population is this prototype package of curriculum materials in population education. The workshop notes that one of the shortcomings of country programs in population education is that the content integrated in school subjects is…
Fabrication of First 4-m Coils for the LARP MQXFA Quadrupole and Assembly in Mirror Structure
Holik, Eddie Frank; Ambrosio, Giorgio; Anerella, Michael; ...
2017-01-23
The US LHC Accelerator Research Program is constructing prototype interaction region quadrupoles as part of the US in-kind contribution to the Hi-Lumi LHC project. The low-beta MQXFA Q1/Q3 coils have a 4-m length and a 150 mm bore. The design is first validated on short, one meter models (MQXFS) developed as part of the longstanding Nb3Sn quadrupole R&D by LARP in collaboration with CERN. In parallel, facilities and tooling are being developed and refined at BNL, LBNL, and FNAL to enable long coil production, assembly, and cold testing. Long length scale-up is based on the experience from the LARP 90more » mm aperture (TQ-LQ) and 120 mm aperture (HQ and Long HQ) programs. A 4-m long MQXF practice coil was fabricated, water jet cut and analyzed to verify procedures, parts, and tooling. In parallel, the first complete prototype coil (QXFP01a) was fabricated and assembled in a long magnetic mirror, MQXFPM1, to provide early feedback on coil design and fabrication following the successful experience of previous LARP mirror tests.« less
Experience of 12 kA / 16 V SMPS during the HTS Current Leads Test
NASA Astrophysics Data System (ADS)
Panchal, P.; Christian, D.; Panchal, R.; Sonara, D.; Purwar, G.; Garg, A.; Nimavat, H.; Singh, G.; Patel, J.; Tanna, V.; Pradhan, S.
2017-04-01
As a part of up gradation plans in SST-1 Tokamak, one pair of 3.3 kA rated prototype hybrid current leads were developed using Di-BSCCO as High Temperature Superconductors (HTS) and the copper heat exchanger. In order to validate the manufacturing procedure prior to go for series production of such current leads, it was recommended to test these current leads using dedicated and very reliable DC switch mode power supply (SMPS). As part of test facility, 12 kA, 16 VDC programmable SMPS was successfully installed, commissioned and tested. This power supply has special features such as modularity, N+1 redundancy, very low ripple voltage, precise current measurements with Direct Current Current Transformer, CC/CV modes with auto-crossover and auto-sequence programming. As a part of acceptance of this converter, A 5.8 mΩ water-cooled resistive dummy load and PLC based SCADA system is designed, developed for commissioning of power supply. The same power supply was used for the testing of the prototype HTS current leads. The paper describes the salient features and experience of state-of-art of power supply and results obtained from this converter during the HTS current leads test.
Initial Experience With A Prototype Storage System At The University Of North Carolina
NASA Astrophysics Data System (ADS)
Creasy, J. L.; Loendorf, D. D.; Hemminger, B. M.
1986-06-01
A prototype archiving system manufactured by the 3M Corporation has been in place at the University of North Carolina for approximately 12 months. The system was installed as a result of a collaboration between 3M and UNC, with 3M seeking testing of their system, and UNC realizing the need for an archiving system as an essential part of their PACS test-bed facilities. System hardware includes appropriate network and disk interface devices as well as media for both short and long term storage of images and their associated information. The system software includes those procedures necessary to communicate with the network interface elements(NIEs) as well as those procedures necessary to interpret the ACR-NEMA header blocks and to store the images. A subset of the total ACR-NEMA header is parsed and stored in a relational database system. The entire header is stored on disk with the completed study. Interactive programs have been developed that allow radiologists to easily retrieve information about the archived images and to send the full images to a viewing console. Initial experience with the system has consisted primarily of hardware and software debugging. Although the system is ACR-NEMA compatable, further objective and subjective assessments of system performance is awaiting the connection of compatable consoles and acquisition devices to the network.
Research and development of the laser tracker measurement system
NASA Astrophysics Data System (ADS)
Zhang, Z. L.; Zhou, W. H.; Lao, D. B.; Yuan, J.; Dong, D. F. F.; Ji, R. Y. Y.
2013-01-01
The working principle and system design of the laser tracker measurement system are introduced, as well as the key technologies and solutions in the implementation of the system. The design and implementation of the hardware and configuration of the software are mainly researched. The components of the hardware include distance measuring unit, angle measuring unit, tracking and servo control unit and electronic control unit. The distance measuring devices include the relative distance measuring device (IFM) and the absolute distance measuring device (ADM). The main component of the angle measuring device, the precision rotating stage, is mainly comprised of the precision axis and the encoders which are both set in the tracking head. The data processing unit, tracking and control unit and power supply unit are all set in the control box. The software module is comprised of the communication module, calibration and error compensation module, data analysis module, database management module, 3D display module and the man-machine interface module. The prototype of the laser tracker system has been accomplished and experiments have been carried out to verify the proposed strategies of the hardware and software modules. The experiments showed that the IFM distance measuring error is within 0.15mm, the ADM distance measuring error is within 3.5mm and the angle measuring error is within 3" which demonstrates that the preliminary prototype can realize fundamental measurement tasks.
Review, Selection and Installation of a Rapid Prototype Machine
NASA Technical Reports Server (NTRS)
McEndree, Caryl
2008-01-01
The objective of this paper is to impress upon the reader the benefits and advantages of investing in rapid prototyping (additive manufacturing) technology thru the procurement of one or two new rapid prototyping machines and the creation of a new Prototype and Model Lab at the Kennedy Space Center (KSC). This new resource will be available to all of United Space Alliance, LLC (USA), enabling engineers from around the company to pursue a more effective means of communication and design with our co-workers, and our customer, the National Aeronautics and Space Administration (NASA). The Rapid Protoyping/3D printing industry mirrors the transition the CAD industry made several years ago, when companies were trying to justify the expenditure of converting to a 3D based system from a 2D based system. The advantages of using a 3D system seemed to be outweighed by the cost it would take to convert not only legacy 2D drawings into 3D models but the training of personnel to use the 3D CAD software. But the reality was that when a 3D CAD system is employed, it gives engineers a much greater ability to conceive new designs and the ability to engineer new tools and products much more effectively. Rapid Prototyping (RP) is the name given to a host of related technologies that are used to fabricate physical objects directly from Computer Aided Design (CAD) data sources. These methods are generally similar to each other in that they add and bond materials in a layer wise-fashion to form objects, instead of machining away material. The machines used in Rapid Prototyping are also sometimes referred to as Rapid Manufacturing machines due to the fact that some of the parts fabricated in a RP machine can be used as the finished product. The name "Rapid Prototyping" is really a misnomer. It is much more than prototypes and it is not always rapid.
Bhavani, Selvaraj Rani; Senthilkumar, Jagatheesan; Chilambuchelvan, Arul Gnanaprakasam; Manjula, Dhanabalachandran; Krishnamoorthy, Ramasamy; Kannan, Arputharaj
2015-03-27
The Internet has greatly enhanced health care, helping patients stay up-to-date on medical issues and general knowledge. Many cancer patients use the Internet for cancer diagnosis and related information. Recently, cloud computing has emerged as a new way of delivering health services but currently, there is no generic and fully automated cloud-based self-management intervention for breast cancer patients, as practical guidelines are lacking. We investigated the prevalence and predictors of cloud use for medical diagnosis among women with breast cancer to gain insight into meaningful usage parameters to evaluate the use of generic, fully automated cloud-based self-intervention, by assessing how breast cancer survivors use a generic self-management model. The goal of this study was implemented and evaluated with a new prototype called "CIMIDx", based on representative association rules that support the diagnosis of medical images (mammograms). The proposed Cloud-Based System Support Intelligent Medical Image Diagnosis (CIMIDx) prototype includes two modules. The first is the design and development of the CIMIDx training and test cloud services. Deployed in the cloud, the prototype can be used for diagnosis and screening mammography by assessing the cancers detected, tumor sizes, histology, and stage of classification accuracy. To analyze the prototype's classification accuracy, we conducted an experiment with data provided by clients. Second, by monitoring cloud server requests, the CIMIDx usage statistics were recorded for the cloud-based self-intervention groups. We conducted an evaluation of the CIMIDx cloud service usage, in which browsing functionalities were evaluated from the end-user's perspective. We performed several experiments to validate the CIMIDx prototype for breast health issues. The first set of experiments evaluated the diagnostic performance of the CIMIDx framework. We collected medical information from 150 breast cancer survivors from hospitals and health centers. The CIMIDx prototype achieved high sensitivity of up to 99.29%, and accuracy of up to 98%. The second set of experiments evaluated CIMIDx use for breast health issues, using t tests and Pearson chi-square tests to assess differences, and binary logistic regression to estimate the odds ratio (OR) for the predictors' use of CIMIDx. For the prototype usage statistics for the same 150 breast cancer survivors, we interviewed 114 (76.0%), through self-report questionnaires from CIMIDx blogs. The frequency of log-ins/person ranged from 0 to 30, total duration/person from 0 to 1500 minutes (25 hours). The 114 participants continued logging in to all phases, resulting in an intervention adherence rate of 44.3% (95% CI 33.2-55.9). The overall performance of the prototype for the good category, reported usefulness of the prototype (P=.77), overall satisfaction of the prototype (P=.31), ease of navigation (P=.89), user friendliness evaluation (P=.31), and overall satisfaction (P=.31). Positive evaluations given by 100 participants via a Web-based questionnaire supported our hypothesis. The present study shows that women felt favorably about the use of a generic fully automated cloud-based self- management prototype. The study also demonstrated that the CIMIDx prototype resulted in the detection of more cancers in screening and diagnosing patients, with an increased accuracy rate.
NASA Technical Reports Server (NTRS)
Brown, David B.
1991-01-01
The results of research and development efforts of the first six months of Task 1, Phase 3 of the project are presented. The goals of Phase 3 are: (1) to further refine the rule base and complete the comparative rule base evaluation; (2) to implement and evaluate a concurrency testing prototype; (3) to convert the complete (unit-level and concurrency) testing prototype to a workstation environment; and (4) to provide a prototype development document to facilitate the transfer of research technology to a working environment. These goals were partially met and the results are summarized.
NASA Astrophysics Data System (ADS)
Candela, L.; Ruggieri, G.; Giancaspro, A.
2004-09-01
In the sphere of "Multi-Mission Ground Segment" Italian Space Agency project, some innovative technologies such as CORBA[1], Z39.50[2], XML[3], Java[4], Java server Pages[4] and C++ has been experimented. The SSPI system (Space Service Provider Infrastructure) is the prototype of a distributed environment aimed to facilitate the access to Earth Observation (EO) data. SSPI allows to ingests, archive, consolidate, visualize and evaluate these data. Hence, SSPI is not just a database of or a data repository, but an application that by means of a set of protocols, standards and specifications provides a unified access to multi-mission EO data.
Development of Thomson scattering system on Shenguang-III prototype laser facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gong, Tao; Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang, Sichuan 621900; Li, Zhichao
2015-02-15
A Thomson scattering diagnostic system, using a 263 nm laser as the probe beam, is designed and implemented on Shenguang-III prototype laser facility. The probe beam is provided by an additional beam line completed recently. The diagnostic system allows simultaneous measurements of both ion feature and red-shifted electron feature from plasmas in a high-temperature (≥2 keV) and high-density (≥10{sup 21} cm{sup −3}) regime. Delicate design is made to satisfy the requirements for successful detection of the electron feature. High-quality ion feature spectra have already been diagnosed via this system in recent experiments with gas-filled hohlraums.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durfee, Justin David; Frazier, Christopher Rawls; Bandlow, Alisa
Sandia National Laboratories (Sandia) is in Phase 3 Sustainment of development of a prototype tool, currently referred to as the Contingency Contractor Optimization Tool - Prototype (CCOTP), under the direction of OSD Program Support. CCOT-P is intended to help provide senior Department of Defense (DoD) leaders with comprehensive insight into the global availability, readiness and capabilities of the Total Force Mix. The CCOT-P will allow senior decision makers to quickly and accurately assess the impacts, risks and mitigating strategies for proposed changes to force/capabilities assignments, apportionments and allocations options, focusing specifically on contingency contractor planning. During Phase 2 of themore » program, conducted during fiscal year 2012, Sandia developed an electronic storyboard prototype of the Contingency Contractor Optimization Tool that can be used for communication with senior decision makers and other Operational Contract Support (OCS) stakeholders. Phase 3 used feedback from demonstrations of the electronic storyboard prototype to develop an engineering prototype for planners to evaluate. Sandia worked with the DoD and Joint Chiefs of Staff strategic planning community to get feedback and input to ensure that the engineering prototype was developed to closely align with future planning needs. The intended deployment environment was also a key consideration as this prototype was developed. Initial release of the engineering prototype was done on servers at Sandia in the middle of Phase 3. In 2013, the tool was installed on a production pilot server managed by the OUSD(AT&L) eBusiness Center. The purpose of this document is to specify the CCOT-P engineering prototype platform requirements as of May 2016. Sandia developed the CCOT-P engineering prototype using common technologies to minimize the likelihood of deployment issues. CCOT-P engineering prototype was architected and designed to be as independent as possible of the major deployment components such as the server hardware, the server operating system, the database, and the web server. This document describes the platform requirements, the architecture, and the implementation details of the CCOT-P engineering prototype.« less
Performance of a full scale prototype detector at the BR2 reactor for the SoLid experiment
NASA Astrophysics Data System (ADS)
Abreu, Y.; Amhis, Y.; Arnold, L.; Ban, G.; Beaumont, W.; Bongrand, M.; Boursette, D.; Castle, B. C.; Clark, K.; Coupé, B.; Cussans, D.; De Roeck, A.; D'Hondt, J.; Durand, D.; Fallot, M.; Ghys, L.; Giot, L.; Guillon, B.; Ihantola, S.; Janssen, X.; Kalcheva, S.; Kalousis, L. N.; Koonen, E.; Labare, M.; Lehaut, G.; Manzanillas, L.; Mermans, J.; Michiels, I.; Moortgat, C.; Newbold, D.; Park, J.; Pestel, V.; Petridis, K.; Piñera, I.; Pommery, G.; Popescu, L.; Pronost, G.; Rademacker, J.; Ryckbosch, D.; Ryder, N.; Saunders, D.; Schune, M.-H.; Simard, L.; Vacheret, A.; Van Dyck, S.; Van Mulders, P.; van Remortel, N.; Vercaemer, S.; Verstraeten, M.; Weber, A.; Yermia, F.
2018-05-01
The SoLid collaboration has developed a new detector technology to detect electron anti-neutrinos at close proximity to the Belgian BR2 reactor at surface level. A 288 kg prototype detector was deployed in 2015 and collected data during the operational period of the reactor and during reactor shut-down. Dedicated calibration campaigns were also performed with gamma and neutron sources. This paper describes the construction of the prototype detector with a high control on its proton content and the stability of its operation over a period of several months after deployment at the BR2 reactor site. All detector cells provide sufficient light yields to achieve a target energy resolution of better than 20%/√E(MeV). The capability of the detector to track muons is exploited to equalize the light response of a large number of channels to a precision of 3% and to demonstrate the stability of the energy scale over time. Particle identification based on pulse-shape discrimination is demonstrated with calibration sources. Despite a lower neutron detection efficiency due to triggering constraints, the main backgrounds at the reactor site were determined and taken into account in the shielding strategy for the main experiment. The results obtained with this prototype proved essential in the design optimization of the final detector.
Specifications and Prototype of the Knowledge Repository (V.3.0) and the Knowledge Mediator (V.3.0)
ERIC Educational Resources Information Center
Andreou, Dimitris; Christophides, Vassilis; Flouris, Giorgos; Kotzinos, Dimitris; Pediaditis, Panagiotis; Tsialiamanis, Petros
2009-01-01
This deliverable reports the technical and research development performed until M36 (January 2009) within tasks T5.2 and T5.4 of WP5 in the KP-Lab project, per the latest Description of Work (DoW) 3.2 [DoW3.2]. The described components are included in the KP-Lab Semantic Web Knowledge Middleware (SWKM) Prototype Release 3.0 software that takes…
Preliminary investigations of protein crystal growth using the Space Shuttle
NASA Technical Reports Server (NTRS)
Delucas, L. J.; Suddath, F. L.; Snyder, R.; Naumann, R.; Broom, M. B.; Pusey, M.; Yost, V.; Herren, B .; Carter, D.
1986-01-01
Four preliminary Shuttle experiments are described which have been used to develop prototype hardware for a more advanced system that will evaluate effects of gravity on protein crystal growth. The first phase of these experiments has centered on the development of micromethods for protein crystal growth by vapor-diffusion techniques (using a space version of the hanging-drop method) and on dialysis using microdialysis cells. Results suggest that the elimination of density-driven sedimentation can effect crystal morphology. In the dialysis experiment, space-grown crystals of concanavalin B were three times longer and 1/3 the thickness of earth-grown crystals.
Miniaturized inertial impactor for personal airborne particulate monitoring: Prototyping
NASA Astrophysics Data System (ADS)
Pasini, Silvia; Bianchi, Elena; Dubini, Gabriele; Cortelezzi, Luca
2017-11-01
Computational fluid dynamic (CFD) simulations allowed us to conceive and design a miniaturized inertial impactor able to collect fine airborne particulate matter (PM10, PM2.5 and PM1). We created, by 3D printing, a prototype of the impactor. We first performed a set of experiments by applying a suction pump to the outlets and sampling the airborne particulate of our laboratory. The analysis of the slide showed a collection of a large number of particles, spanning a wide range of sizes, organized in a narrow band located below the exit of the nozzle. In order to show that our miniaturized inertial impactor can be truly used as a personal air-quality monitor, we performed a second set of experiments where the suction needed to produce the airflow through the impactor is generated by a human being inhaling through the outlets of the prototype. To guarantee a number of particles sufficient to perform a quantitative characterization, we collected particles performing ten consecutive deep inhalations. Finally, the potentiality for realistic applications of our miniaturized inertial impactor used in combination with a miniaturized single-particle detector will be discussed. CARIPLO Fundation - project MINUTE (Grant No. 2011-2118).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1975-12-01
This motor could be used to drive large solar panels of future satellites. Results of investigations concerning a breadboard model without a relaxation torque and a prototype with a relaxation torque are presented. For volume 1; see ESR-97066. (GRA)
NASA Astrophysics Data System (ADS)
Patil, S. N.; Mulay, A. V.; Ahuja, B. B.
2018-04-01
Unlike in the traditional manufacturing processes, additive manufacturing as rapid prototyping, allows designers to produce parts that were previously considered too complex to make economically. The shift is taking place from plastic prototype to fully functional metallic parts by direct deposition of metallic powders as produced parts can be directly used for desired purpose. This work is directed towards the development of experimental setup of metal rapid prototyping machine using selective laser sintering and studies the various parameters, which plays important role in the metal rapid prototyping using SLS technique. The machine structure in mainly divided into three main categories namely, (1) Z-movement of bed and table, (2) X-Y movement arrangement for LASER movements and (3) feeder mechanism. Z-movement of bed is controlled by using lead screw, bevel gear pair and stepper motor, which will maintain the accuracy of layer thickness. X-Y movements are controlled using timing belt and stepper motors for precise movements of LASER source. Feeder mechanism is then developed to control uniformity of layer thickness metal powder. Simultaneously, the study is carried out for selection of material. Various types of metal powders can be used for metal RP as Single metal powder, mixture of two metals powder, and combination of metal and polymer powder. Conclusion leads to use of mixture of two metals powder to minimize the problems such as, balling effect and porosity. Developed System can be validated by conducting various experiments on manufactured part to check mechanical and metallurgical properties. After studying the results of these experiments, various process parameters as LASER properties (as power, speed etc.), and material properties (as grain size and structure etc.) will be optimized. This work is mainly focused on the design and development of cost effective experimental setup of metal rapid prototyping using SLS technique which will gives the feel of metal rapid prototyping process and its important parameters.
ERIC Educational Resources Information Center
ERICKSEN, GERALD L.; RYAN, JAMES J.
A REPORT IS GIVEN OF THE FIRST 3 YEARS OF A FIELD STUDY CONDUCTED TO DETERMINE THE EFFECTIVENESS OF SEVERAL PROTOTYPE, SECONDARY MATHEMATICS PROGRAMS THAT WERE PRODUCED BY DIFFERENT CURRICULUM DEVELOPMENT GROUPS. MATHEMATICS TEACHERS WHO HAD NO PREVIOUS EXPERIENCE WITH "MODERN" OR EXPERIMENTAL APPROACHES TO MATHEMATICS TAUGHT A SELECTED…
ERIC Educational Resources Information Center
Virginia Polytechnic Inst. and State Univ., Blacksburg.
Volume 3 of a three volume final report presents prototype job training plans developed as part of a research project which pilot tested a distributive education program for rural schools utilizing a retail store simulation plan. The plans are for 15 entry-level and 15 career-level jobs in seven categories of distributive business (department…
Implicit face prototype learning from geometric information.
Or, Charles C-F; Wilson, Hugh R
2013-04-19
There is evidence that humans implicitly learn an average or prototype of previously studied faces, as the unseen face prototype is falsely recognized as having been learned (Solso & McCarthy, 1981). Here we investigated the extent and nature of face prototype formation where observers' memory was tested after they studied synthetic faces defined purely in geometric terms in a multidimensional face space. We found a strong prototype effect: The basic results showed that the unseen prototype averaged from the studied faces was falsely identified as learned at a rate of 86.3%, whereas individual studied faces were identified correctly 66.3% of the time and the distractors were incorrectly identified as having been learned only 32.4% of the time. This prototype learning lasted at least 1 week. Face prototype learning occurred even when the studied faces were further from the unseen prototype than the median variation in the population. Prototype memory formation was evident in addition to memory formation of studied face exemplars as demonstrated in our models. Additional studies showed that the prototype effect can be generalized across viewpoints, and head shape and internal features separately contribute to prototype formation. Thus, implicit face prototype extraction in a multidimensional space is a very general aspect of geometric face learning. Copyright © 2013 Elsevier Ltd. All rights reserved.
Mockup design of personal health diary app for patients with chronic kidney disease.
Lin, Hsiu-Wen; Wang, Yu-Jen; Jing, Ling-Fang; Chang, Polun
2014-01-01
Health self-management is important in the care of patients with chronic kidney disease. It is possible to improve the efficiency of patient self-management through the use of mobile technology and related software. This study is divided into three stages: 1. analysis of need: through observation, interview and content analysis of the chronic kidney disease health management manual; 2. design of system prototype: establish interface and system function; 3. prototype evaluation: evaluate whether the prototype designed by this study meets user needs. The system prototype includes: daily record, laboratory examination results, trend graphs, information search, sharing, communications and settings. Prototyping is done with Pencil Project for interface design and linking. The prototype is then exported in PDF format for mock-up simulation. Evaluation results: overall score was 4.01±0.60 leaning towards "agree", the highest score was ease of use (4.25±0.6), followed by easy to learn (4.15±0.68), acceptance (4.01±0.61), reliability (3.87±0.6) and functionality (3.83±0.49). The results show positive attitude towards the system.
Cockpit Ocular Recording System (CORS)
NASA Technical Reports Server (NTRS)
Rothenheber, Edward; Stokes, James; Lagrossa, Charles; Arnold, William; Dick, A. O.
1990-01-01
The overall goal was the development of a Cockpit Ocular Recording System (CORS). Four tasks were used: (1) the development of the system; (2) the experimentation and improvement of the system; (3) demonstrations of the working system; and (4) system documentation. Overall, the prototype represents a workable and flexibly designed CORS system. For the most part, the hardware use for the prototype system is off-the-shelf. All of the following software was developed specifically: (1) setup software that the user specifies the cockpit configuration and identifies possible areas in which the pilot will look; (2) sensing software which integrates the 60 Hz data from the oculometer and heat orientation sensing unit; (3) processing software which applies a spatiotemporal filter to the lookpoint data to determine fixation/dwell positions; (4) data recording output routines; and (5) playback software which allows the user to retrieve and analyze the data. Several experiments were performed to verify the system accuracy and quantify system deficiencies. These tests resulted in recommendations for any future system that might be constructed.
Design, fabrication, and verification of a three-dimensional autocollimator.
Yin, Yanhe; Cai, Sheng; Qiao, Yanfeng
2016-12-10
The autocollimator is an optical instrument for noncontact angle measurement with high resolution and a long detection range. It measures two-dimensional angles, i.e., pitch and yaw, but not roll. In this paper, we present a novelly structured autocollimator capable of measuring three-dimensional (3D) angles simultaneously. In this setup, two collimated beams of different wavelengths are projected onto a right-angle prism. One beam is reflected by the hypotenuse of the prism and received by an autocollimation unit for detecting pitch and yaw. The other is reflected by the two legs of the right-angle prism and received by a moiré fringe imaging unit for detecting roll. Furthermore, a prototype is designed and fabricated. Experiments are carried out to evaluate its basic performance. Calibration results show that this prototype has angular RMS errors of less than 5 arcsec in all 3Ds over a range of 1000 arcsec at a working distance of 2 m.
Development of 3He LPSDs and read-out system for the SANS spectrometer at CPHS
NASA Astrophysics Data System (ADS)
Huang, T. C.; Gong, H.; Shao, B. B.; Wang, X. W.; Zhang, Y.; Pang, B. B.
2014-01-01
The Compact Pulsed Hadron Source (CPHS) is a 13-MeV proton-linac-driven neutron source under construction in Tsinghua University. Time-of-flight (TOF) small-angle neutron scattering (SANS) spectrometer is one of the first instruments to be built. It is designed to use linear position-sensitive detectors (LPSDs) of 3He gas proportional counters to cover a 1 m×1 m area. Prototypical LPSDs (Φ = 12 mm, L=1 m) have been made and read-out system is developed based on charge division. This work describes the in-house fabrication of the prototypical LPSDs and design of the read-out system including front-end electronics and data acquisition (DAQ) system. Key factors of the front-end electronics are studied and optimized with PSPICE simulation. DAQ system is designed based on VME bus architecture and FPGA Mezzanine Card (FMC) standard with high flexibility and extendibility. Preliminary experiments are carried out and the results are present and discussed.
The HD(CP)2 Observational Prototype Experiment HOPE - Overview and Examples
NASA Astrophysics Data System (ADS)
Macke, Andreas
2017-04-01
The "HD(CP)2 Observational Prototype Experiment" (HOPE) was executed as a major 2-month field experiment in Jülich, Germany, performed in April and May 2013, followed by a smaller campaign in Melpitz, Germany in September 2013. HOPE has been designed to provide information on land-surface-atmospheric boundary layer exchange, aerosol, cloud and precipitation pattern for process studies and model evaluation with a focuses on the onset of clouds and precipitation in the convective atmospheric boundary layer. HOPE-Jülich instrumentation included a radio sounding station, 4 Doppler lidars, 4 Raman lidars,1 water vapour differential absorption lidar, 3 cloud radars, 5 microwave radiometers, 3 rain radars, 6 sky imagers, 99 pyranometers, and 4 Sun photometers operated in synergy at different supersites. The HOPE-Melpitz campaign combined ground-based remote sensing of aerosols and clouds with helicopter- and ballon-based in-situ observations in the atmospheric column and at the surface. HOPE provided an unprecedented collection of atmospheric dynamical, thermodynamical, and micro- and macrophysical properties of aerosols, clouds and precipitation with high spatial and temporal resolution within a cube of approximately 10 x 10 x 10 km3. HOPE data will significantly contribute to our understanding of boundary layer dynamics and the formation of clouds and precipitation. The datasets are made available through the Standardized Atmospheric Measurement Data SAMD archive at https://icdc.cen.uni-hamburg.de/index.php?id=samd. The presentation is based on an overview paper in ACP where results published in an ACP HOPE special issue are summarized, see http://www.atmos-chem-phys.net/special_issue366.html. Citation: Macke, A., Seifert, P., Baars, H., Beekmans, C., Behrendt, A., Bohn, B., Bühl, J., Crewell, S., Damian, T., Deneke, H., Düsing, S., Foth, A., Di Girolamo, P., Hammann, E., Heinze, R., Hirsikko, A., Kalisch, J., Kalthoff, N., Kinne, S., Kohler, M., Löhnert, U., Madhavan, B. L., Maurer, V., Muppa, S. K., Schween, J., Serikov, I., Siebert, H., Simmer, C., Späth, F., Steinke, S., Träumner, K., Wehner, B., Wieser, A., Wulfmeyer, V., and Xie, X.: The HD(CP)2 Observational Prototype Experiment HOPE - An Overview, Atmos. Chem. Phys. Discuss., doi:10.5194/acp-2016-990, in review, 2016.
de Groot, Mattijs; Field, Robert W.; Buma, Wybren J.
2009-01-01
We report on an experimental approach that reveals crucial details of the composition of singlet-triplet mixed eigenstates in acetylene. Intersystem crossing in this prototypical polyatomic molecule embodies the mixing of the lowest excited singlet state (S1) with 3 triplet states (T1, T2, and T3). Using high-energy (157-nm) photons from an F2 laser to record excited-state photoelectron spectra, we have decomposed the mixed eigenstates into their S1, T3, T2, and T1 constituent parts. One example of the interpretive power that ensues from the selective sensitivity of the experiment to the individual electronic state characters is the discovery and examination of destructive interference between two doorway-mediated intersystem crossing pathways. This observation of an interference effect in nonradiative decay opens up possibilities for rational coherent control over molecular excited state dynamics. PMID:19179288
A Thermoelectric Energy Harvesting System for Powering Wireless Sensors in Nuclear Power Plants
NASA Astrophysics Data System (ADS)
Chen, Jie; Klein, Jackson; Wu, Yongjia; Xing, Shaoxu; Flammang, Robert; Heibel, Michael; Zuo, Lei
2016-10-01
Safety is the most important issue in the development of nuclear energy. This paper reports experimental studies of a thermoelectric energy harvesting system designed for integration in a nuclear power plant capable of performing in radiation rich environments and producing enough power to run wireless sensors meant to increase plant safety. Furthermore, the system, which utilizes wasted heat present in coolant system piping, has the unique ability to provide power in both normal and accidental situations, to run the sensors without the need for external power. Two energy harvesting prototypes were designed utilizing a heat pipe for heat transfer. The first can supply a maximum power of 2.25 W using two Bi2Te3 thermoelectric modules of 2.79cm (1.1") × 2.79 cm (1.1”), in a source temperature near 250 °C. A second design was put forward to extend the application in higher-temperature primary loops, in which one PbTe-Bi2Te3 hybrid TEG module of 5.6cm (2.2") × 5.6 cm (2.2") can provide a power of 3.0 W when the hot side temperature reaches 340 °C. In addition to the energy harvester, wireless communication circuits were developed along with an integrated power management circuit for wireless data transmission. A high intensity gamma radiation experiment was conducted during which each component was irradiated. A total dose of 200 kGy±10% (20M rads) was applied to the first prototype in order to approximate the expected lifetime accumulation for one implemented thermoelectric generator. Results showed that thermoelectric modules used in the prototype had no reduction in voltage output throughout irradiation. Throughout the experiment the harvester system witnessed a small voltage drop in open circuit voltage attributed to a reduction in heat pipe performance from radiation exposure. We also acquired a baseline radiation survivability level for non-hardened, non-shielded electronics of 102 Gy.
SIMS prototype system 3 test results: Engineering analysis
NASA Technical Reports Server (NTRS)
1978-01-01
The results obtained during testing of a closed hydronic drain down solar system designed for space and hot water heating is presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 3 for field installation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bandlow, Alisa; Durfee, Justin David; Frazier, Christopher Rawls
2016-05-01
This requirements document serves as an addendum to the Contingency Contractor Optimization Phase 2, Requirements Document [1] and Phase 3 Requirements Document [2]. The Phase 2 Requirements document focused on the high-level requirements for the tool. The Phase 3 Requirements document provided more detailed requirements to which the engineering prototype was built in Phase 3. This document will provide detailed requirements for features and enhancements being added to the production pilot in the Phase 3 Sustainment.
Making the most of cloud storage - a toolkit for exploitation by WLCG experiments
NASA Astrophysics Data System (ADS)
Alvarez Ayllon, Alejandro; Arsuaga Rios, Maria; Bitzes, Georgios; Furano, Fabrizio; Keeble, Oliver; Manzi, Andrea
2017-10-01
Understanding how cloud storage can be effectively used, either standalone or in support of its associated compute, is now an important consideration for WLCG. We report on a suite of extensions to familiar tools targeted at enabling the integration of cloud object stores into traditional grid infrastructures and workflows. Notable updates include support for a number of object store flavours in FTS3, Davix and gfal2, including mitigations for lack of vector reads; the extension of Dynafed to operate as a bridge between grid and cloud domains; protocol translation in FTS3; the implementation of extensions to DPM (also implemented by the dCache project) to allow 3rd party transfers over HTTP. The result is a toolkit which facilitates data movement and access between grid and cloud infrastructures, broadening the range of workflows suitable for cloud. We report on deployment scenarios and prototype experience, explaining how, for example, an Amazon S3 or Azure allocation can be exploited by grid workflows.
NASA Astrophysics Data System (ADS)
Kraemer, Kurtis Leigh
Micro air vehicles (MAV) are a class of small uninhabited aircraft with dimensions less than 15 cm (6 in) and mass less than 500g (1.1 lbs). The aim of this research was to develop a fast, accurate, low-cost, and repeatable fabrication process for flapping MAV wings. Through the use of the RepRap Mendel open-source fused-deposition modeling (FDM) rapid prototyping machine ("3-D printer"), various wing prototypes were designed and fabricated using a bio-inspired approach. Testing of the aerodynamic performance of both real locust wings and the 3-D printed wing prototypes was performed through axial spin testing. Bending stiffness measurements were also performed on the 3-D printed wings. Through the use of open-source rapid prototyping technology, a fast and low-cost fabrication process for flapping MAV wings has been developed, out of which further understanding of flapping wing design and fabrication has been gained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strelnikov, N.; Vasserman, I.; Xu, J.
As part of the R&D program of the LCLS-II project, a novel 3.4-meter-long undulator prototype with horizontal magnetic field and dynamic force compensation has recently been developed at the Advanced Photon Source (APS). Some previous steps in this development were the shorter 0.8-meter-long and 2.8-meter-long prototypes. Extensive mechanical and magnetic testing was carried out for each prototype, and each prototype was magnetically tuned using magnetic shims. Furthermore, the resulting performance of the 3.4-meter-long undulator prototype meets all requirements for the LCLS-II insertion device, including limits on the field integrals, phase errors, higher-order magnetic moments, and electron-beam trajectory for all operationalmore » gaps, as well as the reproducibility and accuracy of the gap settings.« less
Fan-beam scanning laser optical computed tomography for large volume dosimetry
NASA Astrophysics Data System (ADS)
Dekker, K. H.; Battista, J. J.; Jordan, K. J.
2017-05-01
A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations.
Going to the Mines to Look for Diamonds. Experimenting with Military Recruiting Stations in Malls
2003-01-01
commonplace in the commercial world . The military now has a facility in place to con- duct such evaluations and should take advantage of it ...Prototype MERS Is Used 31 RANDMR1697-3.2 2010 219 Hour of the day A ve ra ge n um be r of r ec ru ite rs in M E R S 7 4 3 2 1 8 0 6 5...visited desti- nations in the United States, this mall draws more visitors per year than Disney World , Graceland, and the Grand Canyon combined. Its
Tactile-Foot Stimulation Can Assist the Navigation of People with Visual Impairment
Velázquez, Ramiro; Pissaloux, Edwige; Lay-Ekuakille, Aimé
2015-01-01
Background. Tactile interfaces that stimulate the plantar surface with vibrations could represent a step forward toward the development of wearable, inconspicuous, unobtrusive, and inexpensive assistive devices for people with visual impairments. Objective. To study how people understand information through their feet and to maximize the capabilities of tactile-foot perception for assisting human navigation. Methods. Based on the physiology of the plantar surface, three prototypes of electronic tactile interfaces for the foot have been developed. With important technological improvements between them, all three prototypes essentially consist of a set of vibrating actuators embedded in a foam shoe-insole. Perceptual experiments involving direction recognition and real-time navigation in space were conducted with a total of 60 voluntary subjects. Results. The developed prototypes demonstrated that they are capable of transmitting tactile information that is easy and fast to understand. Average direction recognition rates were 76%, 88.3%, and 94.2% for subjects wearing the first, second, and third prototype, respectively. Exhibiting significant advances in tactile-foot stimulation, the third prototype was evaluated in navigation tasks. Results show that subjects were capable of following directional instructions useful for navigating spaces. Conclusion. Footwear providing tactile stimulation can be considered for assisting the navigation of people with visual impairments. PMID:27019593
Tactile-Foot Stimulation Can Assist the Navigation of People with Visual Impairment.
Velázquez, Ramiro; Pissaloux, Edwige; Lay-Ekuakille, Aimé
2015-01-01
Background. Tactile interfaces that stimulate the plantar surface with vibrations could represent a step forward toward the development of wearable, inconspicuous, unobtrusive, and inexpensive assistive devices for people with visual impairments. Objective. To study how people understand information through their feet and to maximize the capabilities of tactile-foot perception for assisting human navigation. Methods. Based on the physiology of the plantar surface, three prototypes of electronic tactile interfaces for the foot have been developed. With important technological improvements between them, all three prototypes essentially consist of a set of vibrating actuators embedded in a foam shoe-insole. Perceptual experiments involving direction recognition and real-time navigation in space were conducted with a total of 60 voluntary subjects. Results. The developed prototypes demonstrated that they are capable of transmitting tactile information that is easy and fast to understand. Average direction recognition rates were 76%, 88.3%, and 94.2% for subjects wearing the first, second, and third prototype, respectively. Exhibiting significant advances in tactile-foot stimulation, the third prototype was evaluated in navigation tasks. Results show that subjects were capable of following directional instructions useful for navigating spaces. Conclusion. Footwear providing tactile stimulation can be considered for assisting the navigation of people with visual impairments.
Muon data from a water Cherenkov detector prototype at Colorado State University
NASA Astrophysics Data System (ADS)
Longo, Megan; Mostafa, Miguel
2013-04-01
The High Altitude Water Cherenkov (HAWC) Observatory is a very high energy gamma-ray experiment currently under construction in Sierra Negra in the state of Puebla, Mexico, at an altitude of 4,100 m a.s.l. The HAWC Observatory will consist of 300 water Cherenkov detectors (WCDs), each instrumented with three 8'' photomultiplier tubes (PMTs) and one 10'' high efficiency (HE) PMT. The PMTs are upward facing, anchored to the bottom of a 5 m deep by 7.3 m diameter steel tank, containing a multilayer hermetic plastic bag holding 200,000 L of purified water. The only full size WCD prototype outside of the HAWC site is located at Colorado State University (CSU) in Fort Collins, CO at an altitude of 1,525 m a.s.l. This prototype is instrumented with six 8'' PMTs, one 10'' HE PMT, and the same laser calibration system, electronics, and data acquisition system as the WCDs at the HAWC site. The CSU prototype is additionally equipped with scintillator paddles both under and above the volume of water, temperature probes (in the water, outside, and in the DAQ room), and one covered PMT. Preliminary results for muon rates and their temperature dependance using data collected with the CSU prototype will be presented.
WE-F-16A-02: Design, Fabrication, and Validation of a 3D-Printed Proton Filter for Range Spreading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Remmes, N; Courneyea, L; Corner, S
2014-06-15
Purpose: To design, fabricate and test a 3D-printed filter for proton range spreading in scanned proton beams. The narrow Bragg peak in lower-energy synchrotron-based scanned proton beams can result in longer treatment times for shallow targets due to energy switching time and plan quality degradation due to minimum monitor unit limitations. A filter with variable thicknesses patterned on the same scale as the beam's lateral spot size will widen the Bragg peak. Methods: The filter consists of pyramids dimensioned to have a Gaussian distribution in thickness. The pyramids are 2.5mm wide at the base, 0.6 mm wide at the peak,more » 5mm tall, and are repeated in a 2.5mm pseudo-hexagonal lattice. Monte Carlo simulations of the filter in a proton beam were run using TOPAS to assess the change in depth profiles and lateral beam profiles. The prototypes were constrained to a 2.5cm diameter disk to allow for micro-CT imaging of promising prototypes. Three different 3D printers were tested. Depth-doses with and without the prototype filter were then measured in a ~70MeV proton beam using a multilayer ion chamber. Results: The simulation results were consistent with design expectations. Prototypes printed on one printer were clearly unacceptable on visual inspection. Prototypes on a second printer looked acceptable, but the micro-CT image showed unacceptable voids within the pyramids. Prototypes from the third printer appeared acceptable visually and on micro-CT imaging. Depth dose scans using the prototype from the third printer were consistent with simulation results. Bragg peak width increased by about 3x. Conclusions: A prototype 3D printer pyramid filter for range spreading was successfully designed, fabricated and tested. The filter has greater design flexibility and lower prototyping and production costs compared to traditional ridge filters. Printer and material selection played a large role in the successful development of the filter.« less
Autonomous sensor particle for parameter tracking in large vessels
NASA Astrophysics Data System (ADS)
Thiele, Sebastian; Da Silva, Marco Jose; Hampel, Uwe
2010-08-01
A self-powered and neutrally buoyant sensor particle has been developed for the long-term measurement of spatially distributed process parameters in the chemically harsh environments of large vessels. One intended application is the measurement of flow parameters in stirred fermentation biogas reactors. The prototype sensor particle is a robust and neutrally buoyant capsule, which allows free movement with the flow. It contains measurement devices that log the temperature, absolute pressure (immersion depth) and 3D-acceleration data. A careful calibration including an uncertainty analysis has been performed. Furthermore, autonomous operation of the developed prototype was successfully proven in a flow experiment in a stirred reactor model. It showed that the sensor particle is feasible for future application in fermentation reactors and other industrial processes.
NASA Astrophysics Data System (ADS)
Ferrino, Marinella; Secondo, Ottaviano; Sabbagh, Amir; Della Sala, Emilio
2014-06-01
In the frame of the International Space Station (ISS) Exploitation Program a new toolbox has been realized by TAS-I to accommodate the tools currently in use on the ISS Columbus Module utilizing full-scale prototypes obtained with 3D rapid prototyping. The manufacturing of the flight hardware by means of advanced thermoplastic polymer UL TEM 9085 and additive manufacturing Fused Deposition Modelling (FDM) technology represent innovative elements. In this paper, the results achieved and the lessons learned are analyzed to promote future technology know-how. The acquired experience confirmed that the additive manufacturing process allows to save time/cost and to realize new shapes/features to introduce innovation in products and future design processes for space applications.
Modular focusing ring imaging Cherenkov detector for electron-ion collider experiments
NASA Astrophysics Data System (ADS)
Wong, C. P.; Alfred, M.; Allison, L.; Awadi, M.; Azmoun, B.; Barbosa, F.; Barion, L.; Bennett, J.; Brooks, W.; Butler, C.; Cao, T.; Chiu, M.; Cisbani, E.; Contalbrigo, M.; Datta, A.; Del Dotto, A.; Demarteau, M.; Durham, J. M.; Dzhygadlo, R.; Elder, T.; Fields, D.; Furletova, Y.; Gleason, C.; Grosse-Perdekamp, M.; Harris, J.; Haseler, T. O. S.; He, X.; van Hecke, H.; Horn, T.; Hruschka, A.; Huang, J.; Hyde, C.; Ilieva, Y.; Kalicy, G.; Kimball, M.; Kistenev, E.; Kulinich, Y.; Liu, M.; Majka, R.; McKisson, J.; Mendez, R.; Nadel-Turonski, P.; Park, K.; Peters, K.; Rao, T.; Pisani, R.; Qiang, Y.; Rescia, S.; Rossi, P.; Sarajlic, O.; Sarsour, M.; Schwarz, C.; Schwiening, J.; da Silva, C. L.; Smirnov, N.; Stien, H. D.; Stevens, J.; Sukhanov, A.; Syed, S.; Tate, A. C.; Toh, J.; Towell, C. L.; Towell, R. S.; Tsang, T.; Turisini, M.; Wagner, R.; Wang, J.; Woody, C.; Xi, W.; Xie, J.; Zhao, Z. W.; Zihlmann, B.; Zorn, C.
2017-11-01
A powerful new electron-ioncollider (EIC) has been recommended in the 2015 Long Range Plan for Nuclear Science for probing the partonic structure inside nucleons and nuclei with unprecedented precision and versatility [1]. EIC detectors are currently under development [2], all of which require hadron identification over a broad kinematic range. A prototype ring imaging Cherenkov detector has been developed for hadron identification in the momentum range from 3 GeV/c to 10 GeV/c. The key feature of this new detector is a compact and modular design, achieved by using aerogel as radiator and a Fresnel lens for ring focusing. In this paper, the results from a beam test of a prototype device at Fermilab are reported.
NASA Astrophysics Data System (ADS)
Frederick, M. E.; Cox, E. L.; Friedl, L. A.
2006-12-01
NASA's Earth Science Theme is charged with implementing NASA Strategic Goal 3A to "study Earth from space to advance scientific understanding and meet societal needs." In the course of meeting this objective, NASA produces research results, such as scientific observatories, research models, advanced sensor and space system technology, data active archives and interoperability technology, high performance computing systems, and knowledge products. These research results have the potential to serve society beyond their intended purpose of answering pressing Earth system science questions. NASA's Applied Sciences Program systematically evaluates the potential of the portfolio of research results to serve society by conducting projects in partnership with regional/national scale operational partners with the statutory responsibility to inform decision makers. These projects address NASA's National Applications and the societal benefit areas under the IEOS and GEOSS. Prototyping methods are used in two ways in NASA's Applied Sciences Program. The first is part of the National Applications program element, referred to as Integrated Systems Solutions (ISS) projects. The approach for these projects is to use high fidelity prototypes to benchmark the assimilation of NASA research results into our partners' decision support systems. The outcome from ISS projects is a prototype system that has been rigorously tested with the partner to understand the scientific uncertainty and improved value of their modified system. In many cases, these completed prototypes are adopted or adapted for use by the operational partners. The second falls under the Crosscutting Solutions program element, referred to as Rapid Prototyping (RP) experiments. The approach for RP experiments is to use low fidelity prototypes that are low cost and quickly produced to evaluate the potential of the breadth of NASA research results to serve society. The outcome from the set of RP experiments is an evaluation of many and varied NASA research results for their potential to be candidates for further development as an ISS project. The intention is to seed the community with many creative ideas for projects that use "un-applied" NASA research results to serve society, such as simulations of future missions.
A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters
NASA Astrophysics Data System (ADS)
Rost, A.; Galatyuk, T.; Koenig, W.; Michel, J.; Pietraszko, J.; Skott, P.; Traxler, M.
2017-02-01
A Charge-to-Digital-Converter (QDC) and Time-to-Digital-Converter (TDC) based on a commercial FPGA (Field Programmable Gate Array) was developed to read out PMT signals of the planned HADES electromagnetic calorimeter (ECAL) at GSI Helmholtzzentrum für Schwerionenforschung GmbH (Darmstadt, Germany). The main idea is to convert the charge measurement of a detector signal into a time measurement, where the charge is encoded in the width of a digital pulse, while the arrival time information is encoded in the leading edge time of the pulse. The PaDiWa-AMPS prototype front-end board for the TRB3 (General Purpose Trigger and Readout Board—version 3) which implements this conversion method was developed and qualified. The already well established TRB3 platform provides the needed precise time measurements and serves as a data acquisition system. We present the read-out concept and the performance of the prototype boards in laboratory and also under beam conditions. First steps have been completed in order to adapt this concept to SiPM signals of the hadron calorimeter in the CBM experiment at the planned FAIR facility (Darmstadt).
El Sabbagh, Abdallah; Eleid, Mackram F; Matsumoto, Jane M; Anavekar, Nandan S; Al-Hijji, Mohammed A; Said, Sameh M; Nkomo, Vuyisile T; Holmes, David R; Rihal, Charanjit S; Foley, Thomas A
2018-01-23
Three-dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR). Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre-procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result. 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post-procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model. 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction. © 2018 Wiley Periodicals, Inc.
Harańczyk, M.; Amsler, C.; Badertscher, A.; ...
2010-08-24
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R & D program, including a 3 l prototype developed to test the charge readout system.
Joint Experiment on Scalable Parallel Processors (JESPP) Parallel Data Management
2006-05-01
management and analysis tool, called Simulation Data Grid ( SDG ). The design principles driving the design of SDG are: 1) minimize network communication...or SDG . In this report, an initial prototype implementation of this system is described. This project follows on earlier research, primarily...distributed logging system had some 2 limitations. These limitations will be described in this report, and how the SDG addresses these limitations. 3.0
Development of a self contained heat rejection module, phase 2 and 3
NASA Technical Reports Server (NTRS)
Fleming, M. L.
1976-01-01
The fabrication and testing of a prototype deployable radiator system is described. Vapor compression with a conventional aircraft compressor yielded a net heat rejection effect at high environments while returning low temperature (10 F and 35 F) conditioned fluid to the payload thermal control system. The system is compatible with shuttle orbiter payloads, free flying experiment modules launched from the shuttle, or by another launch vehicle.
Capsule-odometer: a concept to improve accurate lesion localisation.
Karargyris, Alexandros; Koulaouzidis, Anastasios
2013-09-21
In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.
Learning, retention, and generalization of haptic categories
NASA Astrophysics Data System (ADS)
Do, Phuong T.
This dissertation explored how haptic concepts are learned, retained, and generalized to the same or different modality. Participants learned to classify objects into three categories either visually or haptically via different training procedures, followed by an immediate or delayed transfer test. Experiment I involved visual versus haptic learning and transfer. Intermodal matching between vision and haptics was investigated in Experiment II. Experiments III and IV examined intersensory conflict in within- and between-category bimodal situations to determine the degree of perceptual dominance between sight and touch. Experiment V explored the intramodal relationship between similarity and categorization in a psychological space, as revealed by MDS analysis of similarity judgments. Major findings were: (1) visual examination resulted in relatively higher performance accuracy than haptic learning; (2) systematic training produced better category learning of haptic concepts across all modality conditions; (3) the category prototypes were rated newer than any transfer stimulus followed learning both immediately and after a week delay; and, (4) although they converged at the apex of two transformational trajectories, the category prototypes became more central to their respective categories and increasingly structured as a function of learning. Implications for theories of multimodal similarity and categorization behavior are discussed in terms of discrimination learning, sensory integration, and dominance relation.
16 CFR Appendix L to Part 305 - Sample Labels
Code of Federal Regulations, 2010 CFR
2010-01-01
... Part 305—Sample Labels ER29AU07.122 PROTOTYPE LABEL 1 ER29AU07.123 PROTOTYPE LABEL 2 ER29AU07.124 PROTOTYPE LABEL 3 ER29AU07.125 PROTOTYPE LABEL 4 ER29AU07.126 SAMPLE LABEL 1 ER29AU07.127 SAMPLE LABEL 2...
Ultra-Wideband Time-Difference-of-Arrival High Resolution 3D Proximity Tracking System
NASA Technical Reports Server (NTRS)
Ni, Jianjun; Arndt, Dickey; Ngo, Phong; Phan, Chau; Dekome, Kent; Dusl, John
2010-01-01
This paper describes a research and development effort for a prototype ultra-wideband (UWB) tracking system that is currently under development at NASA Johnson Space Center (JSC). The system is being studied for use in tracking of lunar./Mars rovers and astronauts during early exploration missions when satellite navigation systems are not available. U IATB impulse radio (UWB-IR) technology is exploited in the design and implementation of the prototype location and tracking system. A three-dimensional (3D) proximity tracking prototype design using commercially available UWB products is proposed to implement the Time-Difference- Of-Arrival (TDOA) tracking methodology in this research effort. The TDOA tracking algorithm is utilized for location estimation in the prototype system, not only to exploit the precise time resolution possible with UWB signals, but also to eliminate the need for synchronization between the transmitter and the receiver. Simulations show that the TDOA algorithm can achieve the fine tracking resolution with low noise TDOA estimates for close-in tracking. Field tests demonstrated that this prototype UWB TDOA High Resolution 3D Proximity Tracking System is feasible for providing positioning-awareness information in a 3D space to a robotic control system. This 3D tracking system is developed for a robotic control system in a facility called "Moonyard" at Honeywell Defense & System in Arizona under a Space Act Agreement.
Online writer identification using alphabetic information clustering
NASA Astrophysics Data System (ADS)
Tan, Guo Xian; Viard-Gaudin, Christian; Kot, Alex C.
2009-01-01
Writer identification is a topic of much renewed interest today because of its importance in applications such as writer adaptation, routing of documents and forensic document analysis. Various algorithms have been proposed to handle such tasks. Of particular interests are the approaches that use allographic features [1-3] to perform a comparison of the documents in question. The allographic features are used to define prototypes that model the unique handwriting styles of the individual writers. This paper investigates a novel perspective that takes alphabetic information into consideration when the allographic features are clustered into prototypes at the character level. We hypothesize that alphabetic information provides additional clues which help in the clustering of allographic prototypes. An alphabet information coefficient (AIC) has been introduced in our study and the effect of this coefficient is presented. Our experiments showed an increase of writer identification accuracy from 66.0% to 87.0% when alphabetic information was used in conjunction with allographic features on a database of 200 reference writers.
A wireless wearable surface functional electrical stimulator
NASA Astrophysics Data System (ADS)
Wang, Hai-Peng; Guo, Ai-Wen; Zhou, Yu-Xuan; Xia, Yang; Huang, Jia; Xu, Chong-Yao; Huang, Zong-Hao; Lü, Xiao-Ying; Wang, Zhi-Gong
2017-09-01
In this paper, a wireless wearable functional electrical stimulator controlled by Android phone with real-time-varying stimulation parameters for multichannel surface functional electrical stimulation application has been developed. It can help post-stroke patients using more conveniently. This study focuses on the prototype design, including the specific wristband concept, circuits and stimulation pulse-generation algorithm. A novel stimulator circuit with a driving stage using a complementary current source technique is proposed to achieve a high-voltage compliance, a large output impedance and an accurate linear voltage-to-current conversion. The size of the prototype has been significantly decreased to 17 × 7.5 × 1 cm3. The performance of the prototype has been tested with a loaded resistor and wrist extension/flexion movement of three hemiplegic patients. According to the experiments, the stimulator can generate four-channel charge-balanced biphasic stimulation with a voltage amplitude up to 60 V, and the pulse frequency and width can be adjusted in real time with a range of 100-600 μs and 20-80 Hz, respectively.
Tests of a Roman Pot prototype for the TOTEM experiment
NASA Astrophysics Data System (ADS)
Deile, M.; Alagoz, E.; Anelli, G.; Antchev, G.; Ayache, M.; Caspers, F.; Dimovasili, E.; Dinapoli, R.; Drouhin, F.; Eggert, K.; Escourrou, J.L; Fochler, O.; Gill, K.; Grabit, R.; Haung, F.; Jarron, P.; Kaplon, J.; Kroyer, T.; Luntama, T.; Macina, D.; Mattelon, E.; Niewiadomski, H.; Mirabito, L.; Noschis, E.P.; Oriunno, M.; Park, a.; Perrot, A.-L.; Pirotte, O.; Quetsch, J.M.; Regnier, F.; Ruggiero, G.; Saramad, S.; Siegrist, P.; Snoeys, W.; sSouissi, T.; Szczygiel, R.; Troska, J.; Vasey, F.; Verdier, A.; Da Vià, C.; Hasi, J.; Kok, A.; Watts, S.; Kašpar, J.; Kundrát, V.; Lokajíček, M.V.; Smotlacha, J.; Avati, V.; Järvinen, M.; Kalliokoski, M.; Kalliopuska, J.; Kurvinen, K.; Lauhakangas, R.; Oljemark, F.; Orava, R.; Österberg, K.; Palmieri, V.; Saarikko, H.; Soininen, A.; Boccone, V.; Bozzo, M.; Buzzo, A.; Cuneo, S.; Ferro, F.; Macrí, M.; Minutoli, S.; Morelli, A.; Musico, P.; Negri, M.; Santroni, A.; Sette, G.; Sobol, A.; sBerardi, V.; Catanesi, M.G.; Radicioni, E.
The TOTEM collaboration has developed and tested the first prototype of its Roman Pots to be operated in the LHC. TOTEM Roman Pots contain stacks of 10 silicon detectors with strips oriented in two orthogonal directions. To measure proton scattering angles of a few microradians, the detectors will approach the beam centre to a distance of 10 sigma + 0.5 mm (= 1.3 mm). Dead space near the detector edge is minimised by using two novel "edgeless" detector technologies. The silicon detectors are used both for precise track reconstruction and for triggering. The first full-sized prototypes of both detector technologies as well as their read-out electronics have been developed, built and operated. The tests took place first in a fixed-target muon beam at CERN's SPS, and then in the proton beam-line of the SPS accelerator ring. We present the test beam results demonstrating the successful functionality of the system despite slight technical shortcomings to be improved in the near future.
Krahé, Barbara; Bieneck, Steffen; Scheinberger-Olwig, Renate
2007-11-01
The characteristic features of adolescents' sexual scripts were explored in 400 tenth and eleventh graders from Berlin, Germany. Participants rated the prototypical elements of three scripts for heterosexual interactions: (1) the prototypical script for the first consensual sexual intercourse with a new partner as pertaining to adolescents in general (general script); (2) the prototypical script for the first consensual sexual intercourse with a new partner as pertaining to themselves personally (individual script); and (3) the script for a nonconsensual sexual intercourse (rape script). Compared with the general script for the age group as a whole, the individual script contained fewer risk elements related to sexual aggression and portrayed more positive consequences of the sexual interaction. Few gender differences were found, and coital experience did not affect sexual scripts. The rape script was found to be close to the "real rape stereotype." The findings are discussed with respect to the role of sexual scripts as guidelines for behavior, particularly in terms of their significance for the prediction of sexual aggression.
Schaefgen, Benedikt; Heil, Joerg; Barr, Richard G; Radicke, Marcus; Harcos, Aba; Gomez, Christina; Stieber, Anne; Hennigs, André; von Au, Alexandra; Spratte, Julia; Rauch, Geraldine; Rom, Joachim; Schütz, Florian; Sohn, Christof; Golatta, Michael
2018-06-01
To determine the feasibility of a prototype device combining 3D-automated breast ultrasound (ABVS) and digital breast tomosynthesis in a single device to detect and characterize breast lesions. In this prospective feasibility study, the FUSION-X-US prototype was used to perform digital breast tomosynthesis and ABVS in 23 patients with an indication for tomosynthesis based on current guidelines after clinical examination and standard imaging. The ABVS and tomosynthesis images of the prototype were interpreted separately by two blinded experts. The study compares the detection and BI-RADS® scores of breast lesions using only the tomosynthesis and ABVS data from the FUSION-X-US prototype to the results of the complete diagnostic workup. Image acquisition and processing by the prototype was fast and accurate, with some limitations in ultrasound coverage and image quality. In the diagnostic workup, 29 solid lesions (23 benign, including three cases with microcalcifications, and six malignant lesions) were identified. Using the prototype, all malignant lesions were detected and classified as malignant or suspicious by both investigators. Solid breast lesions can be localized accurately and fast by the Fusion-X-US system. Technical improvements of the ultrasound image quality and ultrasound coverage are needed to further study this new device. The prototype combines tomosynthesis and automated 3D-ultrasound (ABVS) in one device. It allows accurate detection of malignant lesions, directly correlating tomosynthesis and ABVS data. The diagnostic evaluation of the prototype-acquired data was interpreter-independent. The prototype provides a time-efficient and technically reliable diagnostic procedure. The combination of tomosynthesis and ABVS is a promising diagnostic approach.
Vertically polarizing undulator with dynamic compensation of magnetic forces
Strelnikov, N.; Vasserman, I.; Xu, J.; ...
2017-01-20
As part of the R&D program of the LCLS-II project, a novel 3.4-meter-long undulator prototype with horizontal magnetic field and dynamic force compensation has recently been developed at the Advanced Photon Source (APS). Some previous steps in this development were the shorter 0.8-meter-long and 2.8-meter-long prototypes. Extensive mechanical and magnetic testing was carried out for each prototype, and each prototype was magnetically tuned using magnetic shims. Furthermore, the resulting performance of the 3.4-meter-long undulator prototype meets all requirements for the LCLS-II insertion device, including limits on the field integrals, phase errors, higher-order magnetic moments, and electron-beam trajectory for all operationalmore » gaps, as well as the reproducibility and accuracy of the gap settings.« less
2015-11-23
realized gain values of−5.0 dBiC and 3.1 dBiC, respectively. Details of the design, optimization, simulation, and the measured results of the fabricated...prototype of this Fig. 4. The measured input VSWR of the antenna prototype shown in Fig. 3. 7 antenna were published in IEEE Transactions on...suppressed. Other prototypes of these types of MEFSSs were also designed and fabricated and characterized. Details of the design and measurement
2015-01-01
Background The Internet has greatly enhanced health care, helping patients stay up-to-date on medical issues and general knowledge. Many cancer patients use the Internet for cancer diagnosis and related information. Recently, cloud computing has emerged as a new way of delivering health services but currently, there is no generic and fully automated cloud-based self-management intervention for breast cancer patients, as practical guidelines are lacking. Objective We investigated the prevalence and predictors of cloud use for medical diagnosis among women with breast cancer to gain insight into meaningful usage parameters to evaluate the use of generic, fully automated cloud-based self-intervention, by assessing how breast cancer survivors use a generic self-management model. The goal of this study was implemented and evaluated with a new prototype called “CIMIDx”, based on representative association rules that support the diagnosis of medical images (mammograms). Methods The proposed Cloud-Based System Support Intelligent Medical Image Diagnosis (CIMIDx) prototype includes two modules. The first is the design and development of the CIMIDx training and test cloud services. Deployed in the cloud, the prototype can be used for diagnosis and screening mammography by assessing the cancers detected, tumor sizes, histology, and stage of classification accuracy. To analyze the prototype’s classification accuracy, we conducted an experiment with data provided by clients. Second, by monitoring cloud server requests, the CIMIDx usage statistics were recorded for the cloud-based self-intervention groups. We conducted an evaluation of the CIMIDx cloud service usage, in which browsing functionalities were evaluated from the end-user’s perspective. Results We performed several experiments to validate the CIMIDx prototype for breast health issues. The first set of experiments evaluated the diagnostic performance of the CIMIDx framework. We collected medical information from 150 breast cancer survivors from hospitals and health centers. The CIMIDx prototype achieved high sensitivity of up to 99.29%, and accuracy of up to 98%. The second set of experiments evaluated CIMIDx use for breast health issues, using t tests and Pearson chi-square tests to assess differences, and binary logistic regression to estimate the odds ratio (OR) for the predictors’ use of CIMIDx. For the prototype usage statistics for the same 150 breast cancer survivors, we interviewed 114 (76.0%), through self-report questionnaires from CIMIDx blogs. The frequency of log-ins/person ranged from 0 to 30, total duration/person from 0 to 1500 minutes (25 hours). The 114 participants continued logging in to all phases, resulting in an intervention adherence rate of 44.3% (95% CI 33.2-55.9). The overall performance of the prototype for the good category, reported usefulness of the prototype (P=.77), overall satisfaction of the prototype (P=.31), ease of navigation (P=.89), user friendliness evaluation (P=.31), and overall satisfaction (P=.31). Positive evaluations given by 100 participants via a Web-based questionnaire supported our hypothesis. Conclusions The present study shows that women felt favorably about the use of a generic fully automated cloud-based self- management prototype. The study also demonstrated that the CIMIDx prototype resulted in the detection of more cancers in screening and diagnosing patients, with an increased accuracy rate. PMID:25830608
3D printed microfluidic mixer for point-of-care diagnosis of anemia.
Plevniak, Kimberly; Campbell, Matthew; Mei He
2016-08-01
3D printing has been an emerging fabrication tool in prototyping and manufacturing. We demonstrated a 3D microfluidic simulation guided computer design and 3D printer prototyping for quick turnaround development of microfluidic 3D mixers, which allows fast self-mixing of reagents with blood through capillary force. Combined with smartphone, the point-of-care diagnosis of anemia from finger-prick blood has been successfully implemented and showed consistent results with clinical measurements. Capable of 3D fabrication flexibility and smartphone compatibility, this work presents a novel diagnostic strategy for advancing personalized medicine and mobile healthcare.
Development of a liquid xenon time projection chamber for the XENON dark matter search
NASA Astrophysics Data System (ADS)
Ni, Kaixuan
This thesis describes the research conducted for the XENON dark matter direct detection experiment. The tiny energy and small cross-section, from the interaction of dark matter particle on the target, requires a low threshold and sufficient background rejection capability of the detector. The XENON experiment uses dual phase technology to detect scintillation and ionization simultaneously from an event in liquid xenon (LXe). The distinct ratio, between scintillation and ionization, for nuclear recoil and electron recoil events provides excellent background rejection potential. The XENON detector is designed to have 3D position sensitivity down to mm scale, which provides additional event information for background rejection. Started in 2002, the XENON project made steady progress in the R&D phase during the past few years. Those include developing sensitive photon detectors in LXe, improving the energy resolution and LXe purity for detecting very low energy events. Two major quantities related to the dark matter detection, the scintillation efficiency and ionization yield of nuclear recoils in LXe, have been established. A prototype dual phase detector (XENON3) has been built and tested extensively in above ground laboratory. The 3D position sensitivity, as well as the background discrimination potential demonstrated from the XENON3 prototype, allows the construction of a 10 kg scale detector (XENON10), to be deployed underground in early 2006. With 99.5% electron recoil rejection efficiency and 16 keVr nuclear recoil energy threshold, XENON10 will be able to probe the WIMP-nucleon cross-section down to 2 x 10-44 cm2 in the supersymmetry parameter space, after one month operation in the Gran Sasso underground laboratory.
A Novel Multi-Digital Camera System Based on Tilt-Shift Photography Technology
Sun, Tao; Fang, Jun-yong; Zhao, Dong; Liu, Xue; Tong, Qing-xi
2015-01-01
Multi-digital camera systems (MDCS) are constantly being improved to meet the increasing requirement of high-resolution spatial data. This study identifies the insufficiencies of traditional MDCSs and proposes a new category MDCS based on tilt-shift photography to improve ability of the MDCS to acquire high-accuracy spatial data. A prototype system, including two or four tilt-shift cameras (TSC, camera model: Nikon D90), is developed to validate the feasibility and correctness of proposed MDCS. Similar to the cameras of traditional MDCSs, calibration is also essential for TSC of new MDCS. The study constructs indoor control fields and proposes appropriate calibration methods for TSC, including digital distortion model (DDM) approach and two-step calibrated strategy. The characteristics of TSC are analyzed in detail via a calibration experiment; for example, the edge distortion of TSC. Finally, the ability of the new MDCS to acquire high-accuracy spatial data is verified through flight experiments. The results of flight experiments illustrate that geo-position accuracy of prototype system achieves 0.3 m at a flight height of 800 m, and spatial resolution of 0.15 m. In addition, results of the comparison between the traditional (MADC II) and proposed MDCS demonstrate that the latter (0.3 m) provides spatial data with higher accuracy than the former (only 0.6 m) under the same conditions. We also take the attitude that using higher accuracy TSC in the new MDCS should further improve the accuracy of the photogrammetry senior product. PMID:25835187
A novel multi-digital camera system based on tilt-shift photography technology.
Sun, Tao; Fang, Jun-Yong; Zhao, Dong; Liu, Xue; Tong, Qing-Xi
2015-03-31
Multi-digital camera systems (MDCS) are constantly being improved to meet the increasing requirement of high-resolution spatial data. This study identifies the insufficiencies of traditional MDCSs and proposes a new category MDCS based on tilt-shift photography to improve ability of the MDCS to acquire high-accuracy spatial data. A prototype system, including two or four tilt-shift cameras (TSC, camera model: Nikon D90), is developed to validate the feasibility and correctness of proposed MDCS. Similar to the cameras of traditional MDCSs, calibration is also essential for TSC of new MDCS. The study constructs indoor control fields and proposes appropriate calibration methods for TSC, including digital distortion model (DDM) approach and two-step calibrated strategy. The characteristics of TSC are analyzed in detail via a calibration experiment; for example, the edge distortion of TSC. Finally, the ability of the new MDCS to acquire high-accuracy spatial data is verified through flight experiments. The results of flight experiments illustrate that geo-position accuracy of prototype system achieves 0.3 m at a flight height of 800 m, and spatial resolution of 0.15 m. In addition, results of the comparison between the traditional (MADC II) and proposed MDCS demonstrate that the latter (0.3 m) provides spatial data with higher accuracy than the former (only 0.6 m) under the same conditions. We also take the attitude that using higher accuracy TSC in the new MDCS should further improve the accuracy of the photogrammetry senior product.
Okonogi, Shinichi; Kondo, Kosuke; Harada, Naoyuki; Masuda, Hiroyuki; Nemoto, Masaaki; Sugo, Nobuo
2017-09-01
As the anatomical three-dimensional (3D) positional relationship around the anterior clinoid process (ACP) is complex, experience of many surgeries is necessary to understand anterior clinoidectomy (AC). We prepared a 3D synthetic image from computed tomographic angiography (CTA) and magnetic resonance imaging (MRI) data and a rapid prototyping (RP) model from the imaging data using a 3D printer. The objective of this study was to evaluate anatomical reproduction of the 3D synthetic image and intraosseous region after AC in the RP model. In addition, the usefulness of the RP model for operative simulation was investigated. The subjects were 51 patients who were examined by CTA and MRI before surgery. The size of the ACP, thickness and length of the optic nerve and artery, and intraosseous length after AC were measured in the 3D synthetic image and RP model, and reproducibility in the RP model was evaluated. In addition, 10 neurosurgeons performed AC in the completed RP models to investigate their usefulness for operative simulation. The RP model reproduced the region in the vicinity of the ACP in the 3D synthetic image, including the intraosseous region, at a high accuracy. In addition, drilling of the RP model was a useful operative simulation method of AC. The RP model of the vicinity of ACP, prepared using a 3D printer, showed favorable anatomical reproducibility, including reproduction of the intraosseous region. In addition, it was concluded that this RP model is useful as a surgical education tool for drilling.
Zeng, Fei-huang; Xu, Yuan-zhi; Fang, Li; Tang, Xiao-shan
2012-02-01
To describe a new technique for fabricating an 3D resin model by 3D reconstruction and rapid prototyping, and to analyze the precision of this method. An optical grating scanner was used to acquire the data of silastic cavity block , digital dental cast was reconstructed with the data through Geomagic Studio image processing software. The final 3D reconstruction was saved in the pattern of Stl. The 3D resin model was fabricated by fuse deposition modeling, and was compared with the digital model and gypsum model. The data of three groups were statistically analyzed using SPSS 16.0 software package. No significant difference was found in gypsum model,digital dental cast and 3D resin model (P>0.05). Rapid prototyping manufacturing and digital modeling would be helpful for dental information acquisition, treatment design, appliance manufacturing, and can improve the communications between patients and doctors.
Rapid prototyping of an EEG-based brain-computer interface (BCI).
Guger, C; Schlögl, A; Neuper, C; Walterspacher, D; Strein, T; Pfurtscheller, G
2001-03-01
The electroencephalogram (EEG) is modified by motor imagery and can be used by patients with severe motor impairments (e.g., late stage of amyotrophic lateral sclerosis) to communicate with their environment. Such a direct connection between the brain and the computer is known as an EEG-based brain-computer interface (BCI). This paper describes a new type of BCI system that uses rapid prototyping to enable a fast transition of various types of parameter estimation and classification algorithms to real-time implementation and testing. Rapid prototyping is possible by using Matlab, Simulink, and the Real-Time Workshop. It is shown how to automate real-time experiments and perform the interplay between on-line experiments and offline analysis. The system is able to process multiple EEG channels on-line and operates under Windows 95 in real-time on a standard PC without an additional digital signal processor (DSP) board. The BCI can be controlled over the Internet, LAN or modem. This BCI was tested on 3 subjects whose task it was to imagine either left or right hand movement. A classification accuracy between 70% and 95% could be achieved with two EEG channels after some sessions with feedback using an adaptive autoregressive (AAR) model and linear discriminant analysis (LDA).
Development of a Novel Wireless Electric Power Transfer System for Space Applications
NASA Technical Reports Server (NTRS)
VazquezRamos, Gabriel; Yuan, Jiann-Shiun
2011-01-01
This paper will introduce a new implementation for wireless electric power transfer systems: space applications. Due to the risks that constitute the use of electrical connector for some space missions/applications, a simple wireless power system design approach will be evaluated as an alternative for the use of electrical connectors. This approach takes into consideration the overall system performance by designing the magnetic resonance elements and by verifying the overall system electrical behavior. System characterization is accomplished by executing circuit and analytical simulations using Matlab(TradeMark) and LTSpiceIV(TradeMark) software packages. The design methodology was validated by two different experiments: frequency consideration (design of three magnetic elements) and a small scale proof-ofconcept prototype. Experiment results shows successful wireless power transfer for all the cases studied. The proof-of-concept prototype provided approx.4 W of wireless power to the load (light bulb) at a separation of 3 cm from the source. In addition. a resonant circuit was designed and installed to the battery terminals of a handheld radio without batteries, making it tum on at a separation of approx.5 cm or less from the source. It was also demonstrated by prototype experimentation that multiple loads can be powered wirelessly at the same time with a single electric power source.
O'Brien, Nicola; Heaven, Ben; Teal, Gemma; Evans, Elizabeth H; Cleland, Claire; Moffatt, Suzanne; Sniehotta, Falko F; White, Martin; Mathers, John C
2016-01-01
Background Integrating stakeholder involvement in complex health intervention design maximizes acceptability and potential effectiveness. However, there is little methodological guidance about how to integrate evidence systematically from various sources in this process. Scientific evidence derived from different approaches can be difficult to integrate and the problem is compounded when attempting to include diverse, subjective input from stakeholders. Objective The intent of the study was to describe and appraise a systematic, sequential approach to integrate scientific evidence, expert knowledge and experience, and stakeholder involvement in the co-design and development of a complex health intervention. The development of a Web-based lifestyle intervention for people in retirement is used as an example. Methods Evidence from three systematic reviews, qualitative research findings, and expert knowledge was compiled to produce evidence statements (stage 1). Face validity of these statements was assessed by key stakeholders in a co-design workshop resulting in a set of intervention principles (stage 2). These principles were assessed for face validity in a second workshop, resulting in core intervention concepts and hand-drawn prototypes (stage 3). The outputs from stages 1-3 were translated into a design brief and specification (stage 4), which guided the building of a functioning prototype, Web-based intervention (stage 5). This prototype was de-risked resulting in an optimized functioning prototype (stage 6), which was subject to iterative testing and optimization (stage 7), prior to formal pilot evaluation. Results The evidence statements (stage 1) highlighted the effectiveness of physical activity, dietary and social role interventions in retirement; the idiosyncratic nature of retirement and well-being; the value of using specific behavior change techniques including those derived from the Health Action Process Approach; and the need for signposting to local resources. The intervention principles (stage 2) included the need to facilitate self-reflection on available resources, personalization, and promotion of links between key lifestyle behaviors. The core concepts and hand-drawn prototypes (stage 3) had embedded in them the importance of time use and work exit planning, personalized goal setting, and acceptance of a Web-based intervention. The design brief detailed the features and modules required (stage 4), guiding the development of wireframes, module content and functionality, virtual mentors, and intervention branding (stage 5). Following an iterative process of intervention testing and optimization (stage 6), the final Web-based intervention prototype of LEAP (Living, Eating, Activity, and Planning in retirement) was produced (stage 7). The approach was resource intensive and required a multidisciplinary team. The design expert made an invaluable contribution throughout the process. Conclusions Our sequential approach fills an important methodological gap in the literature, describing the stages and techniques useful in developing an evidence-based complex health intervention. The systematic and rigorous integration of scientific evidence, expert knowledge and experience, and stakeholder input has resulted in an intervention likely to be acceptable and feasible. PMID:27489143
O'Brien, Nicola; Heaven, Ben; Teal, Gemma; Evans, Elizabeth H; Cleland, Claire; Moffatt, Suzanne; Sniehotta, Falko F; White, Martin; Mathers, John C; Moynihan, Paula
2016-08-03
Integrating stakeholder involvement in complex health intervention design maximizes acceptability and potential effectiveness. However, there is little methodological guidance about how to integrate evidence systematically from various sources in this process. Scientific evidence derived from different approaches can be difficult to integrate and the problem is compounded when attempting to include diverse, subjective input from stakeholders. The intent of the study was to describe and appraise a systematic, sequential approach to integrate scientific evidence, expert knowledge and experience, and stakeholder involvement in the co-design and development of a complex health intervention. The development of a Web-based lifestyle intervention for people in retirement is used as an example. Evidence from three systematic reviews, qualitative research findings, and expert knowledge was compiled to produce evidence statements (stage 1). Face validity of these statements was assessed by key stakeholders in a co-design workshop resulting in a set of intervention principles (stage 2). These principles were assessed for face validity in a second workshop, resulting in core intervention concepts and hand-drawn prototypes (stage 3). The outputs from stages 1-3 were translated into a design brief and specification (stage 4), which guided the building of a functioning prototype, Web-based intervention (stage 5). This prototype was de-risked resulting in an optimized functioning prototype (stage 6), which was subject to iterative testing and optimization (stage 7), prior to formal pilot evaluation. The evidence statements (stage 1) highlighted the effectiveness of physical activity, dietary and social role interventions in retirement; the idiosyncratic nature of retirement and well-being; the value of using specific behavior change techniques including those derived from the Health Action Process Approach; and the need for signposting to local resources. The intervention principles (stage 2) included the need to facilitate self-reflection on available resources, personalization, and promotion of links between key lifestyle behaviors. The core concepts and hand-drawn prototypes (stage 3) had embedded in them the importance of time use and work exit planning, personalized goal setting, and acceptance of a Web-based intervention. The design brief detailed the features and modules required (stage 4), guiding the development of wireframes, module content and functionality, virtual mentors, and intervention branding (stage 5). Following an iterative process of intervention testing and optimization (stage 6), the final Web-based intervention prototype of LEAP (Living, Eating, Activity, and Planning in retirement) was produced (stage 7). The approach was resource intensive and required a multidisciplinary team. The design expert made an invaluable contribution throughout the process. Our sequential approach fills an important methodological gap in the literature, describing the stages and techniques useful in developing an evidence-based complex health intervention. The systematic and rigorous integration of scientific evidence, expert knowledge and experience, and stakeholder input has resulted in an intervention likely to be acceptable and feasible.
Front and rear projection autostereoscopic 3D displays based on lenticular sheets
NASA Astrophysics Data System (ADS)
Wang, Qiong-Hua; Zang, Shang-Fei; Qi, Lin
2015-03-01
A front projection autostereoscopic display is proposed. The display is composed of eight projectors and a 3D-imageguided screen which having a lenticular sheet and a retro-reflective diffusion screen. Based on the optical multiplexing and de-multiplexing, the optical functions of the 3D-image-guided screen are parallax image interlacing and viewseparating, which is capable of reconstructing 3D images without quality degradation from the front direction. The operating principle, optical design calculation equations and correction method of parallax images are given. A prototype of the front projection autostereoscopic display is developed, which enhances the brightness and 3D perceptions, and improves space efficiency. The performance of this prototype is evaluated by measuring the luminance and crosstalk distribution along the horizontal direction at the optimum viewing distance. We also propose a rear projection autostereoscopic display. The display consists of eight projectors, a projection screen, and two lenticular sheets. The operation principle and calculation equations are described in detail and the parallax images are corrected by means of homography. A prototype of the rear projection autostereoscopic display is developed. The normalized luminance distributions of viewing zones from the measurement are given. Results agree well with the designed values. The prototype presents high resolution and high brightness 3D images. The research has potential applications in some commercial entertainments and movies for the realistic 3D perceptions.
Open-Source Wax RepRap 3-D Printer for Rapid Prototyping Paper-Based Microfluidics.
Pearce, J M; Anzalone, N C; Heldt, C L
2016-08-01
The open-source release of self-replicating rapid prototypers (RepRaps) has created a rich opportunity for low-cost distributed digital fabrication of complex 3-D objects such as scientific equipment. For example, 3-D printable reactionware devices offer the opportunity to combine open hardware microfluidic handling with lab-on-a-chip reactionware to radically reduce costs and increase the number and complexity of microfluidic applications. To further drive down the cost while improving the performance of lab-on-a-chip paper-based microfluidic prototyping, this study reports on the development of a RepRap upgrade capable of converting a Prusa Mendel RepRap into a wax 3-D printer for paper-based microfluidic applications. An open-source hardware approach is used to demonstrate a 3-D printable upgrade for the 3-D printer, which combines a heated syringe pump with the RepRap/Arduino 3-D control. The bill of materials, designs, basic assembly, and use instructions are provided, along with a completely free and open-source software tool chain. The open-source hardware device described here accelerates the potential of the nascent field of electrochemical detection combined with paper-based microfluidics by dropping the marginal cost of prototyping to nearly zero while accelerating the turnover between paper-based microfluidic designs. © 2016 Society for Laboratory Automation and Screening.
Design scheme for optical manufacturing support system of TMT M3 prototype
NASA Astrophysics Data System (ADS)
Hu, Haifei; Luo, Xiao
2014-09-01
Thirty Meter Telescope's Tertiary Mirror Cell Assembly (TMTM3-CA) will be manufactured in Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP). To reduce the risk of fabricating TMTM3, a prototype made of Zerodur with a d/t ratio of 72 is planned to be polished. Here the focus is on the design scheme of the prototype's optical manufacturing support system. Firstly the number of support points was estimated, then structural design scheme for equal-force polishing support system are drawn, and finally layout optimization of support points was carried out. As its high performance and efficiency, the work will be beneficial to manufacturing large thin mirrors.
Evaluation of the Effectiveness of Training Devices: Literature Review and Preliminary Model
1976-04-01
After Smith, 1965) 11 2. Interactions of task categories with training strategies 23 3. Training techniques related to classes of behavior 26 4...necessarily best served by "hands on" experience with real equipment. Instead, these processes may be better served by the simulative device, since It, unlike...could be contrasted in terms of their predicted effectiveness, with the best design package being selected for prototype development and broad- scale
Scotten, Lawrence N; Siegel, Rolland
2015-08-01
Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring the anti-coagulation independent mechanical valve within reach.
Siegel, Rolland
2015-01-01
Background Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Methods Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Results Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Conclusions Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring the anti-coagulation independent mechanical valve within reach. PMID:26417581
Ganpule, Arvind P; Deshmukh, Chaitanya S; Joshi, Tanmay
2018-01-01
The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a" key" instrument to accomplish this arduous task. The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.
Ganpule, Arvind P.; Deshmukh, Chaitanya S.; Joshi, Tanmay
2018-01-01
Introduction: The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a ”key” instrument to accomplish this arduous task. Instrument: The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. Validation: We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. Conclusion: The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder. PMID:28782740
Final prototype of magnetically suspended flywheel energy storage system
NASA Technical Reports Server (NTRS)
Anand, D. K.; Kirk, J. A.; Zmood, R. B.; Pang, D.; Lashley, C.
1991-01-01
A prototype of a 500 Wh magnetically suspended flywheel energy storage system was designed, built, and tested. The authors present the work done and include the following: (1) a final design of the magnetic bearing, control system, and motor/generator, (2) construction of a prototype system consisting of the magnetic bearing stack, flywheel, motor, container, and display module, and (3) experimental results for the magnetic bearings, motor, and the entire system. The successful completion of the prototype system has achieved: (1) manufacture of tight tolerance bearings, (2) stability and spin above the first critical frequency, (3) use of inside sensors to eliminate runout problems, and (4) integration of the motor and magnetic bearings.
The moving-ring field-reversed mirror prototype reactor
NASA Astrophysics Data System (ADS)
Smith, A. C., Jr.; Carlson, G. A.; Fleischmann, H. H.; Grossman, W., Jr.; Kammash, T.; Schultz, K. R.; Woodall, D. M.
1981-03-01
A prototype fusion reactor was designed based on magnetic field reversed plasma confinement. A set of physics, technology, and mechanical design criteria were developed in order to make this concept attractive. Six major criteria guide the commercial prototype design. The prototype must: (1) produce net electricity decisively P sub net 70% of P sub gross; (2) scale to an economical commercial plant and have small physical size; (3) have all features required of a correcial upgrade plant (H-3 breeding, etc.); (4) minimize exotic technology and maintenance complexity; (5) promise significantly lower safety hazards than fission plants (environmentally and socially acceptable); and (6) be modular in design to permit repetitive production of components.
Final prototype of magnetically suspended flywheel energy storage system
NASA Astrophysics Data System (ADS)
Anand, D. K.; Kirk, J. A.; Zmood, R. B.; Pang, D.; Lashley, C.
A prototype of a 500 Wh magnetically suspended flywheel energy storage system was designed, built, and tested. The authors present the work done and include the following: (1) a final design of the magnetic bearing, control system, and motor/generator, (2) construction of a prototype system consisting of the magnetic bearing stack, flywheel, motor, container, and display module, and (3) experimental results for the magnetic bearings, motor, and the entire system. The successful completion of the prototype system has achieved: (1) manufacture of tight tolerance bearings, (2) stability and spin above the first critical frequency, (3) use of inside sensors to eliminate runout problems, and (4) integration of the motor and magnetic bearings.
Prototype Effect and the Persuasiveness of Generalizations.
Dahlman, Christian; Sarwar, Farhan; Bååth, Rasmus; Wahlberg, Lena; Sikström, Sverker
An argument that makes use of a generalization activates the prototype for the category used in the generalization. We conducted two experiments that investigated how the activation of the prototype affects the persuasiveness of the argument. The results of the experiments suggest that the features of the prototype overshadow and partly overwrite the actual facts of the case. The case is, to some extent, judged as if it had the features of the prototype instead of the features it actually has. This prototype effect increases the persuasiveness of the argument in situations where the audience finds the judgment more warranted for the prototype than for the actual case (positive prototype effect), but decreases persuasiveness in situations where the audience finds the judgment less warranted for the prototype than for the actual case (negative prototype effect).
Jung, Yunho; Kato, Masayuki; Lee, Jongchan; Gromski, Mark A; Chuttani, Ram; Matthes, Kai
2013-11-01
A prototype endoscope was designed to improve visualization and dissection of tissue with the use of 2 working channels with different deflections. To evaluate the efficacy and operability of a prototype endoscope in comparison with a conventional double-channel endoscope for rectal endoscopic submucosal dissection (ESD). Randomized, prospective, controlled, ex vivo study. Academic medical center. A total of 80 standardized artificial lesions measuring 3 × 3 cm were created approximately 5 cm from the anal verge in fresh ex vivo porcine colorectal specimens. Two endoscopists each completed 20 cases with the prototype endoscope and 20 cases with the conventional endoscope. An independent observer recorded procedure time, specimen size, en bloc resection, and perforation rate. For the ESD novice, the mean submucosal dissection time (10.5 ± 3.8 vs 14.9 ± 7.3 minutes; P = .024) and total procedure time (18.1 ± 5.2 vs 23.6 ± 8.2 minutes; P = .015) were significantly shorter in the prototype group in comparison with the conventional group. For the ESD expert, there was no significant difference between the mean circumferential resection, submucosal dissection, and total procedure time (prototype group 14.2 ± 6.0 minutes, conventional group 14.2 ± 8.8 minutes; P = .992). The overall perforation and en bloc resection rates were not significantly different between groups. Ex vivo study. In this ex vivo prospective comparison study, there was a technical advantage for the ESD novice with the prototype endoscope that resulted in a shorter procedure time, which was not observed for cases performed by the ESD expert. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Speidel, Michael A; Tomkowiak, Michael T; Raval, Amish N; Dunkerley, David A P; Slagowski, Jordan M; Kahn, Paul; Ku, Jamie; Funk, Tobias
Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system for low dose cardiac imaging. The use of a narrow scanned x-ray beam in SBDX reduces detected x-ray scatter and improves dose efficiency, however the tight beam collimation also limits the maximum achievable x-ray fluence. To increase the fluence available for imaging, we have constructed a new SBDX prototype with a wider x-ray beam, larger-area detector, and new real-time image reconstructor. Imaging is performed with a scanning source that generates 40,328 narrow overlapping projections from 71 × 71 focal spot positions for every 1/15 s scan period. A high speed 2-mm thick CdTe photon counting detector was constructed with 320×160 elements and 10.6 cm × 5.3 cm area (full readout every 1.28 μs), providing an 86% increase in area over the previous SBDX prototype. A matching multihole collimator was fabricated from layers of tungsten, brass, and lead, and a multi-GPU reconstructor was assembled to reconstruct the stream of captured detector images into full field-of-view images in real time. Thirty-two tomosynthetic planes spaced by 5 mm plus a multiplane composite image are produced for each scan frame. Noise equivalent quanta on the new SBDX prototype measured 63%-71% higher than the previous prototype. X-ray scatter fraction was 3.9-7.8% when imaging 23.3-32.6 cm acrylic phantoms, versus 2.3-4.2% with the previous prototype. Coronary angiographic imaging at 15 frame/s was successfully performed on the new SBDX prototype, with live display of either a multiplane composite or single plane image.
Laser Cooled Atomic Clocks in Space
NASA Technical Reports Server (NTRS)
Thompson, R. J.; Kohel, J.; Klipstein, W. M.; Seidel, D. J.; Maleki, L.
2000-01-01
The goals of the Glovebox Laser-cooled Atomic Clock Experiment (GLACE) are: (1) first utilization of tunable, frequency-stabilized lasers in space, (2) demonstrate laser cooling and trapping in microgravity, (3) demonstrate longest 'perturbation-free' interaction time for a precision measurement on neutral atoms, (4) Resolve Ramsey fringes 2-10 times narrower than achievable on Earth. The approach taken is: the use of COTS components, and the utilization of prototype hardware from LCAP flight definition experiments. The launch date is scheduled for Oct. 2002. The Microgravity Science Glovebox (MSG) specifications are reviewed, and a picture of the MSG is shown.
16 CFR 1633.6 - Quality assurance requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... that mattress sets manufactured for sale are the same as the qualified and/or confirmed prototype on... lot that is represented by the prototype; and (3) Inspection of mattress sets produced for sale... for sale according to the requirements of §§ 1633.3 and 1633.7. (c) Failure of mattress sets produced...
16 CFR 1633.6 - Quality assurance requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... that mattress sets manufactured for sale are the same as the qualified and/or confirmed prototype on... lot that is represented by the prototype; and (3) Inspection of mattress sets produced for sale... for sale according to the requirements of §§ 1633.3 and 1633.7. (c) Failure of mattress sets produced...
3D/Additive Printing Manufacturing: A Brief History and Purchasing Guide
ERIC Educational Resources Information Center
Hughes, Bill; Wilson, Greg
2016-01-01
3D printing is recognized as a collection of technologies known as rapid prototyping, solid freeform fabrication, and most commonly, additive manufacturing (AM). With these emerging technologies it is possible to print (but not limited to): architectural models, discontinued car-part foundry patterns, industry-wide prototypes, human tissues, the…
As part of an effort to link pharmacokinetics with biochemical and physiological endpoints, the relationships between cholinesterase (ChE) activity and tissue levels of a prototypical N-methyl carbamate pesticide were examined. In a dose-response study, carbaryl (0, 3, 7.5, 15, 3...
The HD(CP)2 Observational Prototype Experiment (HOPE) - an overview
NASA Astrophysics Data System (ADS)
Macke, Andreas; Seifert, Patric; Baars, Holger; Barthlott, Christian; Beekmans, Christoph; Behrendt, Andreas; Bohn, Birger; Brueck, Matthias; Bühl, Johannes; Crewell, Susanne; Damian, Thomas; Deneke, Hartwig; Düsing, Sebastian; Foth, Andreas; Di Girolamo, Paolo; Hammann, Eva; Heinze, Rieke; Hirsikko, Anne; Kalisch, John; Kalthoff, Norbert; Kinne, Stefan; Kohler, Martin; Löhnert, Ulrich; Lakshmi Madhavan, Bomidi; Maurer, Vera; Muppa, Shravan Kumar; Schween, Jan; Serikov, Ilya; Siebert, Holger; Simmer, Clemens; Späth, Florian; Steinke, Sandra; Träumner, Katja; Trömel, Silke; Wehner, Birgit; Wieser, Andreas; Wulfmeyer, Volker; Xie, Xinxin
2017-04-01
The HD(CP)2 Observational Prototype Experiment (HOPE) was performed as a major 2-month field experiment in Jülich, Germany, in April and May 2013, followed by a smaller campaign in Melpitz, Germany, in September 2013. HOPE has been designed to provide an observational dataset for a critical evaluation of the new German community atmospheric icosahedral non-hydrostatic (ICON) model at the scale of the model simulations and further to provide information on land-surface-atmospheric boundary layer exchange, cloud and precipitation processes, as well as sub-grid variability and microphysical properties that are subject to parameterizations. HOPE focuses on the onset of clouds and precipitation in the convective atmospheric boundary layer. This paper summarizes the instrument set-ups, the intensive observation periods, and example results from both campaigns. HOPE-Jülich instrumentation included a radio sounding station, 4 Doppler lidars, 4 Raman lidars (3 of them provide temperature, 3 of them water vapour, and all of them particle backscatter data), 1 water vapour differential absorption lidar, 3 cloud radars, 5 microwave radiometers, 3 rain radars, 6 sky imagers, 99 pyranometers, and 5 sun photometers operated at different sites, some of them in synergy. The HOPE-Melpitz campaign combined ground-based remote sensing of aerosols and clouds with helicopter- and balloon-based in situ observations in the atmospheric column and at the surface. HOPE provided an unprecedented collection of atmospheric dynamical, thermodynamical, and micro- and macrophysical properties of aerosols, clouds, and precipitation with high spatial and temporal resolution within a cube of approximately 10 × 10 × 10 km3. HOPE data will significantly contribute to our understanding of boundary layer dynamics and the formation of clouds and precipitation. The datasets have been made available through a dedicated data portal. First applications of HOPE data for model evaluation have shown a general agreement between observed and modelled boundary layer height, turbulence characteristics, and cloud coverage, but they also point to significant differences that deserve further investigations from both the observational and the modelling perspective.
ROBITOM-robot for biopsy and therapy of the mamma.
Felden, A; Vagner, J; Hinz, A; Fischer, H; Pfleiderer, S O R; Reichenbach, J R; Kaiser, W A
2002-01-01
MR-Mammography reaches a high sensitivity in detecting breast carcinomas of 3 mm in size at least. In cooperation with the Institute of Diagnostic and Interventional Radiology of the Friedrich-Schiller-University of Jena, a manipulator has been developed by the IMB, which combines the advantages of MRM imaging with a minimal invasive biopsy and a possible subsequent therapy. Referring to this ROBITOM I was introduced in November 1999 as worldwide first, precise operating manipulator system in the ISO center of a closed MR, at RSNA in Chicago. Clinical trials started at 22. November 2000. The experiences and results of these tests were brought into the following prototype ROBITOM II, that is currently developed at the IMB. The completion of this Prototype is planned at the end of 2002.
Experiment neutrino-4 on searching for a sterile neutrino with multisection detector model
NASA Astrophysics Data System (ADS)
Serebrov, A. P.; Ivochkin, V. G.; Samoilov, R. M.; Fomin, A. K.; Zinov'ev, V. G.; Neustroev, P. V.; Golovtsov, V. L.; Chernyi, A. V.; Zherebtsov, O. M.; Polyushkin, A. O.; Martem'yanov, V. P.; Tarasenkov, V. G.; Aleshin, V. I.; Petelin, A. L.; Izhutov, A. L.; Tuzov, A. A.; Sazontov, S. A.; Ryazanov, D. K.; Gromov, M. O.; Afanas'ev, V. V.; Zaitsev, M. E.; Chaikovskii, M. E.
2017-02-01
A laboratory for searching for oscillations of reactor antineutrinos has been created based on the SM-3 reactor in order to approach the problem of the possible existence of a sterile neutrino. The multisection detector prototype with a liquid scintillator volume of 350 L was installed in mid-2015. This detector can move inside the passive shield in a range of 6-11 m from the active core of the reactor. The antineutrino flux was measured for the first time at these short distances from the active core of the reactor by the movable detector. The measurements with the multisection detector prototype demonstrated that it is possible to measure the antineutrino flux from the reactor in the complicated conditions of cosmic background on the Earth's surface.
Modular focusing ring imaging Cherenkov detector for electron–ion collider experiments
Wong, C. P.; Alfred, M.; Allison, L.; ...
2017-07-16
Here, a powerful new electron–ioncollider (EIC) has been recommended in the 2015 Long Range Plan for Nuclear Science for probing the partonic structure inside nucleons and nuclei with unprecedented precision and versatility. EIC detectors are currently under development, all of which require hadron identification over a broad kinematic range. A prototype ring imaging Cherenkov detector has been developed for hadron identification in the momentum range from 3 GeV/c to 10 GeV/c. The key feature of this new detector is a compact and modular design, achieved by using aerogel as radiator and a Fresnel lens for ring focusing. In this paper,more » the results from a beam test of a prototype device at Fermilab are reported.« less
Neutrino-4 experiment on search for sterile neutrino with multi-section model of detector
NASA Astrophysics Data System (ADS)
Serebrov, A.; Ivochkin, V.; Samoilov, R.; Fomin, A.; Polyushkin, A.; Zinoviev, V.; Neustroev, P.; Golovtsov, V.; Chernyj, A.; Zherebtsov, O.; Martemyanov, V.; Tarasenkov, V.; Aleshin, V.; Petelin, A.; Izhutov, A.; Tuzov, A.; Sazontov, S.; Ryazanov, D.; Gromov, M.; Afanasiev, V.; Zaytsev, M.; Chaikovskii, M.
2017-09-01
In order to carry out research in the field of possible existence of a sterile neutrino the laboratory based on SM-3 reactor (Dimitrovgrad, Russia) was created to search for oscillations of reactor antineutrino. The prototype of a multi-section neutrino detector with liquid scintillator volume of 350 l was installed in the middle of 2015. It is a moveable inside the passive shielding detector, which can be set at distance range from 6 to 11 meters from the reactor core. Measurements of antineutrino flux at such small distances from the reactor core are carried out with moveable detector for the first time. The measurements carried out with detector prototype demonstrated a possibility of measuring a reactor antineutrino flux in difficult conditions of cosmic background at Earth surface.
High-Voltage Characterization for the Prototype Induction Cells
NASA Astrophysics Data System (ADS)
Huacen, Wang; Kaizhi, Zhang; Long, Wen; Qinggui, Lai; Linwen, Zhang; Jianjun, Deng
2002-12-01
Two linear induction prototype cells expected to work at 250kV, 3kA,with accelerating voltage flattop (±1%) ⩾ 70ns, have been tested to determine their high-voltage characteristics. Each cell is composed of a ferrite core immersed in oil, a gap with curved stainless steel electrodes, a solenoid magnet, and a insulator. The experiments were carried out with full-scale cells. The high voltage pulses were applied to two cells using a 100ns, 12Ω pulse Blumlein. The tests were performed at various high-voltage levels ranging from -250kV to -350kV. No breakdown was observed during the test at vacuum level (7-10) ṡ10-4 Pa. The cell schematic, the experimental set up, and the measured voltage waveforms are presented in this paper.
Zhu, Yanbo; Yang, Bin; Liu, Jingquan; Wang, Xingzhao; Wang, Luxian; Chen, Xiang; Yang, Chunsheng
2016-01-01
Recently, triboelectric energy nanogenerators (TENGs) have been paid the most attention by many researchers to convert mechanical energy into electrical energy. TENGs usually have a simple structure and a high output voltage. However, their high internal resistance results in low output power. In this work, we propose a flexible triboelectric energy nanogenerator with the double-side tribological layers of polydimethlysiloxane (PDMS) and PDMS/multiwall carbon nanotube (MWCNT). MWCNTs with different concentrations have been doped into PDMS to tune the internal resistance of triboelectric nanogenerator and optimize its output power. The dimension of the fabricated prototype is ~3.6 cm3. Three-axial force sensor is used to monitor the applied vertical forces on the device under vertical contact-separation working mode. The Prototype with 10 wt% MWCNT (Prototype I) produces higher output voltage than one with 2 wt% MWCNT (Prototype II) due to its higher dielectric parameter measured by LRC impedance analyzer. The triboelectric output voltages of Prototype I and Prototype II are 30 V and 25 V under the vertical force of 3.0 N, respectively. Their maximum triboelectric output powers are ~130 μW at 6 MΩ and ~120 μW at 8.6 MΩ under vertical forces, respectively. PMID:26916819
NASA Astrophysics Data System (ADS)
Zhang, X.; Karanassios, V.
2012-06-01
A solar-powered, battery-operated, atmospheric-pressure, self-igniting microplasma the size of a sugar-cube developed on a hybrid, 3d-chip is described. Rapid prototyping of the 3d-chip; some fundamental aspects and a brief characterization of its background spectral emission using a portable, fiber-optic spectrometer are discussed.
High Throughput System for Plant Height and Hyperspectral Measurement
NASA Astrophysics Data System (ADS)
Zhao, H.; Xu, L.; Jiang, H.; Shi, S.; Chen, D.
2018-04-01
Hyperspectral and three-dimensional measurement can obtain the intrinsic physicochemical properties and external geometrical characteristics of objects, respectively. Currently, a variety of sensors are integrated into a system to collect spectral and morphological information in agriculture. However, previous experiments were usually performed with several commercial devices on a single platform. Inadequate registration and synchronization among instruments often resulted in mismatch between spectral and 3D information of the same target. And narrow field of view (FOV) extends the working hours in farms. Therefore, we propose a high throughput prototype that combines stereo vision and grating dispersion to simultaneously acquire hyperspectral and 3D information.
LCLS-II Cryomodules Production at Fermilab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arkan, Tug; Grimm, Chuck; Kaluzny, Joshua
2017-05-01
LCLS-II is an upgrade project for the linear coherent light source (LCLS) at SLAC. The LCLS-II linac will consist of thirty-five 1.3 GHz and two 3.9 GHz superconducting RF continuous wave (CW) cryomodules that Fermilab and Jefferson Lab (JLab) will assemble in collaboration with SLAC. The LCLS-II 1.3 GHz cryomodule design is based on the European XFEL pulsed-mode cryomodule design with modifications needed for CW operation. Fermilab and JLab will each assemble and test a prototype 1.3 GHz cryomodule to assess the results of the CW modifications, in advance of 16 and 17 production 1.3 GHz cryomodules, respectively. Fermilab ismore » solely responsible for the 3.9 GHz cryomodules. After the prototype cryomodule tests are complete and lessons learned incorporated, both laboratories will increase their cryomodule production rates to meet the challenging LCLS-II project requirement of approximately one cryomodule per month per laboratory. This paper presents the Fermilab Cryomodule Assembly Facility (CAF) infrastructure for LCLS-II cryomodule production, the Fermilab prototype 1.3 GHz CW cryomodule (pCM) assembly and readiness for production assembly.« less
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
Assessment of Data Assimilation with the Prototype High Resolution Rapid Refresh for Alaska (HRRRAK)
NASA Technical Reports Server (NTRS)
Harrison, Kayla; Morton, Don; Zavodsky, Brad; Chou, Shih
2012-01-01
The Arctic Region Supercomputing Center has been running a quasi-operational prototype of a High Resolution Rapid Refresh for Alaska (HRRRAK) at 3km resolution, initialized by the 13km Rapid Refresh (RR). Although the RR assimilates a broad range of observations into its analyses, experiments with the HRRRAK suggest that there may be added value in assimilating observations into the 3km initial conditions, downscaled from the 13km RR analyses. The NASA Short-term Prediction Research and Transition (SPoRT) group has been using assimilated data from the Atmospheric Infrared Sounder (AIRS) in WRF and WRF-Var simulations since 2004 with promising results. The sounder is aboard NASA s Aqua satellite, and provides vertical profiles of temperature and humidity. The Gridpoint Statistical Interpolation (GSI) system is then used to assimilate these vertical profiles into WRF forecasts. In this work, we assess the use of AIRS data in combination with other global data assimilation products on non-assimilated HRRRAK case studies. Two separate weather events will be assessed to qualitatively and quantitatively assess the impacts of AIRS data on HRRRAK forecasts.
NASA Astrophysics Data System (ADS)
Flouzat, C.; Değerli, Y.; Guilloux, F.; Orsini, F.; Venault, P.
2015-05-01
In the framework of the ALICE experiment upgrade at HL-LHC, a new forward tracking detector, the Muon Forward Tracker (MFT), is foreseen to overcome the intrinsic limitations of the present Muon Spectrometer and will perform new measurements of general interest for the whole ALICE physics. To fulfill the new detector requirements, CMOS Monolithic Active Pixel Sensors (MAPS) provide an attractive trade-off between readout speed, spatial resolution, radiation hardness, granularity, power consumption and material budget. This technology has been chosen to equip the Muon Forward Tracker and also the vertex detector: the Inner Tracking System (ITS). Since few years, an intensive R&D program has been performed on the design of MAPS in the 0.18 μ m CMOS Image Sensor (CIS) process. In order to avoid pile up effects in the experiment, the classical rolling shutter readout system of MAPS has been improved to overcome the readout speed limitation. A zero suppression algorithm, based on a 3 by 3 cluster finding (position and data), has been chosen for the MFT. This algorithm allows adequate data compression for the sensor. This paper presents the large size prototype PIXAM, which represents 1/3 of the final chip, and will focus specially on the zero suppression block architecture. This chip is designed and under fabrication in the 0.18 μ m CIS process. Finally, the readout electronics principle to send out the compressed data flow is also presented taking into account the cluster occupancy per MFT plane for a single central Pb-Pb collision.
Efficiency Measurement of VANDLE Modules
NASA Astrophysics Data System (ADS)
Peters, William; Matei, C.; Cizewski, J. A.; O'Malley, P. D.; Spassova, I.; Bardayan, D.; Blackmon, J. C.; Brune, C.; Massey, T.; Grzywacz, R. K.; Madurga, M.; Sarazin, F.; Raiola, F.
2010-02-01
The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new array of plastic scintillator bars being developed at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory (ORNL). The modular design enables optimization of different configurations for particular experiments, such as (d,n) and beta-delayed neutron-decay experiments, with rare ion beams. Two prototype modules were moved to the Edwards Accelerator Laboratory at Ohio University to measure their efficiency using a calibrated ^27Al(d,n) reaction as a neutron source. Results show that one bar with a cross section of 3x3 cm^2 is over 25% efficient to neutrons around 1 MeV with sensitivity down to 100 keV neutrons. Other design features such as wrapping and coupling will be presented, as well as results from resolution tests. )
Stapf, Daniel; Franke, Andreas; Schreckenberg, Marcus; Schummers, Georg; Mischke, Karl; Marx, Nikolaus; Schauerte, Patrick; Knackstedt, Christian
2013-04-01
Three-dimensional (3D)-imaging provides important information on cardiac anatomy during electrophysiological procedures. Real-time updates of modalities with high soft-tissue contrast are particularly advantageous during cardiac procedures. Therefore, a beat to beat 3D visualization of cardiac anatomy by intracardiac echocardiography (ICE) was developed and tested in phantoms and animals. An electronic phased-array 5-10 MHz ICE-catheter (Acuson, AcuNav/Siemens Medical Solutions USA/64 elements) providing a 90° sector image was used for ICE-imaging. A custom-made mechanical prototype controlled by a servo motor allowed automatic rotation of the ICE-catheter around its longitudinal axis. During a single heartbeat, the ICE-catheter was rotated and 2D-images were acquired. Reconstruction into a 3D volume and rendering by a prototype software was performed beat to beat. After experimental validation using a rigid phantom, the system was tested in an animal study and afterwards, for quantitative validation, in a dynamic phantom. Acquisition of beat to beat 3D-reconstruction was technically feasible. However, twisting of the ICE-catheter shaft due to friction and torsion was found and rotation was hampered. Also, depiction of catheters was not always ensured in case of parallel alignment. Using a curved sheath for depiction of cardiac anatomy there was no congruent depiction of shape and dimension of static and moving objects. Beat to beat 3D-ICE-imaging is feasible. However, shape and dimension of static and moving objects cannot always be displayed with necessary steadiness as needed in the clinical setting. As catheter depiction is also limited, clinical use seems impossible.
Charge carrier recombination dynamics in perovskite and polymer solar cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paulke, Andreas; Kniepert, Juliane; Kurpiers, Jona
2016-03-14
Time-delayed collection field experiments are applied to planar organometal halide perovskite (CH{sub 3}NH{sub 3}PbI{sub 3}) based solar cells to investigate charge carrier recombination in a fully working solar cell at the nanosecond to microsecond time scale. Recombination of mobile (extractable) charges is shown to follow second-order recombination dynamics for all fluences and time scales tested. Most importantly, the bimolecular recombination coefficient is found to be time-dependent, with an initial value of ca. 10{sup −9} cm{sup 3}/s and a progressive reduction within the first tens of nanoseconds. Comparison to the prototypical organic bulk heterojunction device PTB7:PC{sub 71}BM yields important differences with regardmore » to the mechanism and time scale of free carrier recombination.« less
Moga, Tudor Voicu; Popescu, Alina; Sporea, Ioan; Danila, Mirela; David, Ciprian; Gui, Vasile; Iacob, Nicoleta; Miclaus, Gratian; Sirli, Roxana
2017-08-23
Contrast enhanced ultrasound (CEUS) improved the characterization of focal liver lesions (FLLs), but is an operatordependent method. The goal of this paper was to test a computer assisted diagnosis (CAD) prototype and to see its benefit in assisting a beginner in the evaluation of FLLs. Our cohort included 97 good quality CEUS videos[34% hepatocellular carcinomas (HCC), 12.3% hypervascular metastases (HiperM), 11.3% hypovascular metastases (HipoM), 24.7% hemangiomas (HMG), 17.5% focal nodular hyperplasia (FNH)] that were used to develop a CAD prototype based on an algorithm that tested a binary decision based classifier. Two young medical doctors (1 year CEUS experience), two experts and the CAD prototype, reevaluated 50 FLLs CEUS videos (diagnosis of benign vs. malignant) first blinded to clinical data, in order to evaluate the diagnostic gap beginner vs. expert. The CAD classifier managed a 75.2% overall (benign vs. malignant) correct classification rate. The overall classification rates for the evaluators, before and after clinical data were: first beginner-78%; 94%; second beginner-82%; 96%; first expert-94%; 100%; second expert-96%; 98%. For both beginners, the malignant vs. benign diagnosis significantly improved after knowing the clinical data (p=0.005; p=0,008). The expert was better than the beginner (p=0.04) and better than the CAD (p=0.001). CAD in addition to the beginner can reach the expert diagnosis. The most frequent lesions misdiagnosed at CEUS were FNH and HCC. The CAD prototype is a good comparing tool for a beginner operator that can be developed to assist the diagnosis. In order to increase the classification rate, the CAD system for FLL in CEUS must integrate the clinical data.
Xia, Delin; Gui, Lai; Zhang, Zhiyong; Lu, Changsheng; Niu, Feng; Jin, Ji; Liu, Xiaoqing
2005-10-01
To investigate the methods of establishing 3-dimensional skull model using electron beam CT (EBCT) data rapid prototyping technique, and to discuss its application in repairing cranio-maxillo-facial trauma. The data were obtained by EBCT continuous volumetric scanning with 1.0 mm slice at thickness. The data were transferred to work-station for 3-dimensional surface reconstruction by computer-aided design software and the images were saved as STL file. The data can be used to control a laser rapid-prototyping device (AFS-320QZ) to construct geometric model. The material for the model construction is a kind of laser-sensitive resin power, which will become a mass when scanned by laser beam. The design and simulation of operation can be done on the model. The image data were transferred to the device slice by slice. Thus a geometric model is constructed according to the image data by repeating this process. Preoperative analysis, surgery simulation and implant of bone defect could be done on this computer-aided manufactured 3D model. One case of cranio-maxillo-facial bone defect resulting from trauma was reconstructed with this method. The EBCT scanning showed that the defect area was 4 cm x 6 cm. The nose was flat and deviated to left. The 3-dimensional skull was reconstructed with EBCT data and rapid prototyping technique. The model can display the structure of 3-dimensional anatomy and their relationship. The prefabricated implant by 3-dimensional model was well-matched with defect. The deformities of flat and deviated nose were corrected. The clinical result was satisfactory after a follow-up of 17 months. The 3-dimensional model of skull can replicate the prototype of disease and play an important role in the diagnosis and simulation of operation for repairing cranio-maxillo-facial trauma.
Prototype Military Message Form (P772) and Mail List Agent (MLA) for National MMHS
2006-12-01
Bakanliklar Ankara TURKEY murat.ucuncu@tr.net A. Betul SASIOGLU National Research Institute of Electronics and Cryptology ( TUBITAK – UEKAE) PK.74...Electronics and Cryptology ( TUBITAK – UEKAE) was used in the system. 3. THE PROTOTYPE NATIONAL MAMF ARCHITECTURE The new national military message...System” [2] ACP 123, "Common Messaging Strategy and Procedures” [3] MA3 ASYA, “PKI Software Developed by Turkish TUBITAK UEKAE” [4] ITU-T X.500
Lee, Doug-Youn; Spångberg, Larz S W; Bok, Young-Bin; Lee, Chang-Young; Kum, Kee-Yeon
2005-07-01
The aim of this in vitro study was to evaluate the suitability of using chitosan, poly (lactide-co-glycolide) (PLGA), and polymethyl methacrylate (PMMA) to control the release of chlorhexidine digluconate (CHX) from a prototype of controlled release drug device for root canal disinfection. Four different prototypes with different formulations were prepared. Group A (n = 12): the device (absorbent paper point) was loaded with CHX as control. Group B (n = 12): same as group A, but the device was coated with chitosan (Texan MedTech). In Groups C and D, the device was treated in the same way as group A and then coated 3 times with 5% PMMA (Group C, n = 12, Aldrich), or coated 3 times with 3% PLGA (Group D, n = 12, Sigma). The devices were randomly allocated to experimental groups of 12 each. All the prototypes of controlled release drug device were soaked in 3 mL distilled water. The concentrations of CHX were determined using a UV spectrophotometer. The surface characteristics of each prototype were observed using a scanning electron microscope. The result showed that release rate of CHX was the greatest in the noncoated group, followed by the chitosan-coated group, the PLGA-coated group, and the PMMA-coated group (P < 0.05). Pores were observed on the surface of the prototypes that were coated with PLGA and PMMA. When the pore size was smaller, the release rate was lower. These data indicate that polymer coating can control the release rate of CHX from the prototypes of controlled release drug device.
Design and performance of a centimetre-scale shrouded wind turbine for energy harvesting
NASA Astrophysics Data System (ADS)
Howey, D. A.; Bansal, A.; Holmes, A. S.
2011-08-01
A miniature shrouded wind turbine aimed at energy harvesting for power delivery to wireless sensors in pipes and ducts is presented. The device has a rotor diameter of 2 cm, with an outer diameter of 3.2 cm, and generates electrical power by means of an axial-flux permanent magnet machine built into the shroud. Fabrication was accomplished using a combination of traditional machining, rapid prototyping, and flexible printed circuit board technology for the generator stator, with jewel bearings providing low friction and start up speed. Prototype devices can operate at air speeds down to 3 m s-1, and deliver between 80 µW and 2.5 mW of electrical power at air speeds in the range 3-7 m s-1. Experimental turbine performance curves, obtained by wind tunnel testing and corrected for bearing losses using data obtained in separate vacuum run-down tests, are compared with the predictions of an elementary blade element momentum (BEM) model. The two show reasonable agreement at low tip speed ratios. However, in experiments where a maximum could be observed, the maximum power coefficient (~9%) is marginally lower than predicted from the BEM model and occurs at a lower than predicted tip speed ratio of around 0.6.
NASA Technical Reports Server (NTRS)
Barhydt, Richard; Eischeid, Todd M.; Palmer, Michael T.; Wing, David J.
2003-01-01
NASA is currently investigating a new concept of operations for the National Airspace System, designed to improve capacity while maintaining or improving current levels of safety. This concept, known as Distributed Air/Ground Traffic Management (DAGTM), allows appropriately equipped autonomous aircraft to maneuver freely for flight optimization while resolving conflicts with other traffic and staying out of special use airspace and hazardous weather. In order to perform these tasks, pilots use prototype conflict detection, prevention, and resolution tools, collectively known as an Airborne Separation Assurance System (ASAS). While ASAS would normally allow pilots to resolve conflicts before they become hazardous, evaluation of system performance in sudden, near-term conflicts is needed in order to determine concept feasibility. An experiment was conducted in NASA Langley's Air Traffic Operations Lab to evaluate the prototype ASAS for enabling pilots to resolve near-term conflicts and examine possible operational effects associated with the use of lower separation minimums. Sixteen commercial airline pilots flew a total of 32 traffic scenarios that required them to use prototype ASAS tools to resolve close range pop-up conflicts. Required separation standards were set at either 3 or 5 NM lateral spacing, with 1000 ft vertical separation being used for both cases. Reducing the lateral separation from 5 to 3 NM did not appear to increase operational risk, as indicated by the proximity to the intruder aircraft. Pilots performed better when they followed tactical guidance cues provided by ASAS than when they didn't follow the guidance. In an effort to improve compliance rate, ASAS design changes are currently under consideration. Further studies will of evaluate these design changes and consider integration issues between ASAS and existing Airborne Collision Avoidance Systems (ACAS).
A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.
Schulz-Wendtland, Rüdiger; Jud, Sebastian M; Fasching, Peter A; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W; Emons, Julius
2017-06-01
The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound - the second important imaging modality in complementary breast diagnostics - without increasing examination time or requiring additional staff.
Chen, Qi; Thomas, Joseph T; Giménez-Lirola, Luis G; Hardham, John M; Gao, Qinshan; Gerber, Priscilla F; Opriessnig, Tanja; Zheng, Ying; Li, Ganwu; Gauger, Phillip C; Madson, Darin M; Magstadt, Drew R; Zhang, Jianqiang
2016-04-05
At least two genetically different porcine epidemic diarrhea virus (PEDV) strains have been identified in the United States (U.S. PEDV prototype and S-INDEL-variant strains). The current serological assays offered at veterinary diagnostic laboratories for detection of PEDV-specific antibody are based on the U.S. PEDV prototype strain. The objectives of this study were: 1) isolate the U.S. PEDV S-INDEL-variant strain in cell culture; 2) generate antisera against the U.S. PEDV prototype and S-INDEL-variant strains by experimentally infecting weaned pigs; 3) determine if the various PEDV serological assays could detect antibodies against the U.S. PEDV S-INDEL-variant strain and vice versa. A U.S. PEDV S-INDEL-variant strain was isolated in cell culture in this study. Three groups of PEDV-negative, 3-week-old pigs (five pigs per group) were inoculated orally with a U.S. PEDV prototype isolate (previously isolated in our lab), an S-INDEL-variant isolate or virus-negative culture medium. Serum samples collected at 0, 7, 14, 21 and 28 days post inoculation were evaluated by the following PEDV serological assays: 1) indirect fluorescent antibody (IFA) assays using the prototype and S-INDEL-variant strains as indicator viruses; 2) virus neutralization (VN) tests against the prototype and S-INDEL-variant viruses; 3) PEDV prototype strain whole virus based ELISA; 4) PEDV prototype strain S1-based ELISA; and 5) PEDV S-INDEL-variant strain S1-based ELISA. The positive antisera against the prototype strain reacted to and neutralized both prototype and S-INDEL-variant viruses, and the positive antisera against the S-INDEL-variant strain also reacted to and neutralized both prototype and S-INDEL-variant viruses, as examined by IFA antibody assays and VN tests. Antibodies against the two PEDV strains could be detected by all three ELISAs although detection rates varied to some degree. These data indicate that the antibodies against U.S. PEDV prototype and S-INDEL-variant strains cross-reacted and cross-neutralized both strains in vitro. The current serological assays based on U.S. PEDV prototype strain can detect antibodies against both U.S. PEDV strains.
Thawani, Jayesh P; Singh, Nickpreet; Pisapia, Jared M; Abdullah, Kalil G; Parker, Drew; Pukenas, Bryan A; Zager, Eric L; Verma, Ragini; Brem, Steven
2017-04-01
Diffuse low-grade gliomas (DLGGs) represent several pathological entities that infiltrate and invade cortical and subcortical structures in the brain. To describe methods for rapid prototyping of DLGGs and surgically relevant anatomy. Using high-definition imaging data and rapid prototyping technologies, we were able to generate 3 patient DLGGs to scale and represent the associated white matter tracts in 3 dimensions using advanced diffusion tensor imaging techniques. This report represents a novel application of 3-dimensional (3-D) printing in neurosurgery and a means to model individualized tumors in 3-D space with respect to subcortical white matter tract anatomy. Faculty and resident evaluations of this technology were favorable at our institution. Developing an understanding of the anatomic relationships existing within individuals is fundamental to successful neurosurgical therapy. Imaging-based rapid prototyping may improve on our ability to plan for and treat complex neuro-oncologic pathology. Copyright © 2017 by the Congress of Neurological Surgeons
A comparative approach to computer aided design model of a dog femur.
Turamanlar, O; Verim, O; Karabulut, A
2016-01-01
Computer assisted technologies offer new opportunities in medical imaging and rapid prototyping in biomechanical engineering. Three dimensional (3D) modelling of soft tissues and bones are becoming more important. The accuracy of the analysis in modelling processes depends on the outline of the tissues derived from medical images. The aim of this study is the evaluation of the accuracy of 3D models of a dog femur derived from computed tomography data by using point cloud method and boundary line method on several modelling software. Solidworks, Rapidform and 3DSMax software were used to create 3D models and outcomes were evaluated statistically. The most accurate 3D prototype of the dog femur was created with stereolithography method using rapid prototype device. Furthermore, the linearity of the volumes of models was investigated between software and the constructed models. The difference between the software and real models manifests the sensitivity of the software and the devices used in this manner.
Nakada, Takeo; Inagaki, Takuya
2014-01-01
Preoperative three-dimensional (3D) imaging of a mediastinal tumor using two-dimensional (2D) axial computed tomography is sometimes difficult, and an unexpected appearance of the tumor may be encountered during surgery. In order to evaluate the preoperative feasibility of a 3D mediastinal model that used the rapid prototyping technique, we created a model and report its results. The 2D image showed some of the relationship between the tumor and the pericardium, but the 3D mediastinal model that was created using the rapid prototyping technique showed the 3D lesion in the outer side of the extrapericardium. The patient underwent a thoracoscopic resection of the tumor, and the pathological examination showed a rare middle mediastinal ectopic thymoma. We believe that the construction of mediastinal models is useful for thoracoscopic surgery and other complicated surgeries of the chest diseases. PMID:24633133
Akiba, Tadashi; Nakada, Takeo; Inagaki, Takuya
2015-01-01
Preoperative three-dimensional (3D) imaging of a mediastinal tumor using two-dimensional (2D) axial computed tomography is sometimes difficult, and an unexpected appearance of the tumor may be encountered during surgery. In order to evaluate the preoperative feasibility of a 3D mediastinal model that used the rapid prototyping technique, we created a model and report its results. The 2D image showed some of the relationship between the tumor and the pericardium, but the 3D mediastinal model that was created using the rapid prototyping technique showed the 3D lesion in the outer side of the extrapericardium. The patient underwent a thoracoscopic resection of the tumor, and the pathological examination showed a rare middle mediastinal ectopic thymoma. We believe that the construction of mediastinal models is useful for thoracoscopic surgery and other complicated surgeries of the chest diseases.
Psychophysical experiments on the PicHunter image retrieval system
NASA Astrophysics Data System (ADS)
Papathomas, Thomas V.; Cox, Ingemar J.; Yianilos, Peter N.; Miller, Matt L.; Minka, Thomas P.; Conway, Tiffany E.; Ghosn, Joumana
2001-01-01
Psychophysical experiments were conducted on PicHunter, a content-based image retrieval (CBIR) experimental prototype with the following properties: (1) Based on a model of how users respond, it uses Bayes's rule to predict what target users want, given their actions. (2) It possesses an extremely simple user interface. (3) It employs an entropy- based scheme to improve convergence. (4) It introduces a paradigm for assessing the performance of CBIR systems. Experiments 1-3 studied human judgment of image similarity to obtain data for the model. Experiment 4 studied the importance of using: (a) semantic information, (b) memory of earlier input, and (c) relative and absolute judgments of similarity. Experiment 5 tested an approach that we propose for comparing performances of CBIR systems objectively. Finally, experiment 6 evaluated the most informative display-updating scheme that is based on entropy minimization, and confirmed earlier simulation results. These experiments represent one of the first attempts to quantify CBIR performance based on psychophysical studies, and they provide valuable data for improving CBIR algorithms. Even though they were designed with PicHunter in mind, their results can be applied to any CBIR system and, more generally, to any system that involves judgment of image similarity by humans.
Prototype to measure bracket debonding force in vivo.
Tonus, Jéssika Lagni; Manfroi, Fernanda Borguetti; Borges, Gilberto Antonio; Grigolo, Eduardo Correa; Helegda, Sérgio; Spohr, Ana Maria
2017-02-01
Material biodegradation that occurs in the mouth may interfere in the bonding strength between the bracket and the enamel, causing lower bond strength values in vivo, in comparison with in vitro studies. To develop a prototype to measure bracket debonding force in vivo and to evaluate, in vitro, the bond strength obtained with the prototype. A original plier (3M Unitek) was modified by adding one strain gauge directly connected to its claw. An electronic circuit performed the reading of the strain gauge, and the software installed in a computer recorded the values of the bracket debonding force, in kgf. Orthodontic brackets were bonded to the facial surface of 30 bovine incisors with adhesive materials. In Group 1 (n = 15), debonding was carried out with the prototype, while tensile bond strength testing was performed in Group 2 (n = 15). A universal testing machine was used for the second group. The adhesive remnant index (ARI) was recorded. According to Student's t test (α = 0.05), Group 1 (2.96 MPa) and Group 2 (3.08 MPa) were not significantly different. ARI score of 3 was predominant in the two groups. The prototype proved to be reliable for obtaining in vivo bond strength values for orthodontic brackets.
Reconceiving ISD: Three Perspectives on Rapid Prototyping as a Paradigm Shift.
ERIC Educational Resources Information Center
Rathbun, Gail A.; And Others
Confronting recent design challenges, instructional designers have latched onto adaptive procedural techniques from outside the Instructional Systems Design (ISD) field. This discussion of rapid prototyping (RP) examines the perspectives of: (1) the prototype as the designer"s cognitive tool; (2) the designer as co-inquirer; and (3) the…
Four experimental demonstrations of active vibration control for flexible structures
NASA Technical Reports Server (NTRS)
Phillips, Doug; Collins, Emmanuel G., Jr.
1990-01-01
Laboratory experiments designed to test prototype active-vibration-control systems under development for future flexible space structures are described, summarizing previously reported results. The control-synthesis technique employed for all four experiments was the maximum-entropy optimal-projection (MEOP) method (Bernstein and Hyland, 1988). Consideration is given to: (1) a pendulum experiment on large-amplitude LF dynamics; (2) a plate experiment on broadband vibration suppression in a two-dimensional structure; (3) a multiple-hexagon experiment combining the factors studied in (1) and (2) to simulate the complexity of a large space structure; and (4) the NASA Marshall ACES experiment on a lightweight deployable 45-foot beam. Extensive diagrams, drawings, graphs, and photographs are included. The results are shown to validate the MEOP design approach, demonstrating that good performance is achievable using relatively simple low-order decentralized controllers.
1994-02-01
LiNbO 3. Preliminary prediction of the defect densities in X = 0.17 LWIR Hgl.xZnxTe were made and compared to results in HgCdTe. We continued to...Preliminary prediction of the defect densities in z = 0.17 LWIR Hgl-,Zn:Te. * Continued development of a method to calculate the temperature de- pendence of... LWIR HgZnTe 4 3 WIDE-GAP I-VI COMPOUNDS (ZnSe AS PROTOTYPE) 6 4 NONLINEAR OPTICAL MATERIALS (LiNb0 3 AS THE PROTOTYPE) 9 5 WORK PLANNED 9 APPENDIX A
Novel Applications of Rapid Prototyping in Gamma-ray and X-ray Imaging
Miller, Brian W.; Moore, Jared W.; Gehm, Michael E.; Furenlid, Lars R.; Barrett, Harrison H.
2010-01-01
Advances in 3D rapid-prototyping printers, 3D modeling software, and casting techniques allow for the fabrication of cost-effective, custom components in gamma-ray and x-ray imaging systems. Applications extend to new fabrication methods for custom collimators, pinholes, calibration and resolution phantoms, mounting and shielding components, and imaging apertures. Details of the fabrication process for these components are presented, specifically the 3D printing process, cold casting with a tungsten epoxy, and lost-wax casting in platinum. PMID:22984341
Low cost lab-on-a-chip prototyping with a consumer grade 3D printer.
Comina, Germán; Suska, Anke; Filippini, Daniel
2014-08-21
Versatile prototyping of 3D printed lab-on-a-chip devices, supporting different forms of sample delivery, transport, functionalization and readout, is demonstrated with a consumer grade printer, which centralizes all critical fabrication tasks. Devices cost 0.57US$ and are demonstrated in chemical sensing and micromixing examples, which exploit established principles from reference technologies.
Development of real-time motion capture system for 3D on-line games linked with virtual character
NASA Astrophysics Data System (ADS)
Kim, Jong Hyeong; Ryu, Young Kee; Cho, Hyung Suck
2004-10-01
Motion tracking method is being issued as essential part of the entertainment, medical, sports, education and industry with the development of 3-D virtual reality. Virtual human character in the digital animation and game application has been controlled by interfacing devices; mouse, joysticks, midi-slider, and so on. Those devices could not enable virtual human character to move smoothly and naturally. Furthermore, high-end human motion capture systems in commercial market are expensive and complicated. In this paper, we proposed a practical and fast motion capturing system consisting of optic sensors, and linked the data with 3-D game character with real time. The prototype experiment setup is successfully applied to a boxing game which requires very fast movement of human character.
1986-03-27
RD-RI69 841 THE AS (ADMINISTRATIVE SCIENCES) FINANCIAL REPORTING i4 SYSTEN: SOME EXPERIE.. (U) NAVAL POSTGRADUATE SCHOOL MONTEREY CA R L BOOKER 27...Monterey, California * II LECp THESIS THE AS FINANCIAL REPORTING SYSTEM: SOME EXPERIENCE ON PROTOTYPING AND USER INTERACTION by Ronald L. Booker March...7ASK WORK UNIT ELEMENT NO. NO. NO ACCESSION NO ’ITITLE (Include Security Cassfication) THE AS FINANCIAL REPORTING SYSTEM: SOME EXPERIENCE ON PROTOTYPING
NASA Technical Reports Server (NTRS)
Jackson, L. Neal; Crenshaw, John, Sr.; Schulze, Arthur E.; Wood, H. J., Jr.
1989-01-01
The objective was to define the factors which space flight hardware developers and planners should consider when determining: (1) the number of hardware units required to support program; (2) design level of the units; and (3) most efficient means of utilization of the units. The analysis considered technology risk, maintainability, reliability, and safety design requirements for achieving the delivery of highest quality flight hardware. Relative cost impacts of the utilization of prototyping were identified. The development of Space Biology Initiative research hardware will involve intertwined hardware/software activities. Experience has shown that software development can be an expensive portion of a system design program. While software prototyping could imply the development of a significantly different end item, an operational system prototype must be considered to be a combination of software and hardware. Hundreds of factors were identified that could be considered in determining the quantity and types of prototypes that should be constructed. In developing the decision models, these factors were combined and reduced by approximately ten-to-one in order to develop a manageable structure based on the major determining factors. The Baseline SBI hardware list of Appendix D was examined and reviewed in detail; however, from the facts available it was impossible to identify the exact types and quantities of prototypes required for each of these items. Although the factors that must be considered could be enumerated for each of these pieces of equipment, the exact status and state of development of the equipment is variable and uncertain at this time.
Run-Time Support for Rapid Prototyping
1988-12-01
prototyping. One such system is the Computer-Aided Proto- typing System (CAPS). It combines rapid prototypng with automatic program generation. Some of the...a design database, and a design management system [Ref. 3:p. 66. By using both rapid prototyping and automatic program genera- tion. CAPS will be...Most proto- typing systems perform these functions. CAPS is different in that it combines rapid prototyping with a variant of automatic program
Performance of large area x-ray proportional counters in a balloon experiment
NASA Astrophysics Data System (ADS)
Roy, J.; Agrawal, P. C.; Dedhia, D. K.; Manchanda, R. K.; Shah, P. B.; Chitnis, V. R.; Gujar, V. M.; Parmar, J. V.; Pawar, D. M.; Kurhade, V. B.
2016-10-01
ASTROSAT is India's first satellite fully devoted to astronomical observations covering a wide spectral band from optical to hard X-rays by a complement of 4 co-aligned instruments and a Scanning Sky X-ray Monitor. One of the instruments is Large Area X-ray Proportional Counter with 3 identical detectors. In order to assess the performance of this instrument, a balloon experiment with two prototype Large Area X-ray Proportional Counters (LAXPC) was carried out on 2008 April 14. The design of these LAXPCs was similar to those on the ASTROSAT except that their field of view (FOV) was 3 ∘ × 3 ∘ versus FOV of 1 ∘ × 1 ∘ for the LAXPCs on the ASTROSAT. The LAXPCs are aimed at the timing and spectral studies of X-ray sources in 3-80 keV region. In the balloon experiment, the LAXPC, associated electronics and support systems were mounted on an oriented platform which could be pre-programmed to track any source in the sky. A brief description of the LAXPC design, laboratory tests, calibration and the detector characteristics is presented here. The details of the experiment and background counting rates of the 2 LAXPCs at the float altitude of about 41 km are presented in different energy bands. The bright black hole X-ray binary Cygnus X-1 (Cyg X-1) was observed in the experiment for ˜ 3 hours. Details of Cyg X-1 observations, count rates measured from it in different energy intervals and the intensity variations of Cyg X-1 detected during the observations are presented and briefly discussed.
The Accidental Transgressor: Morally Relevant Theory of Mind
Killen, Melanie; Mulvey, Kelly Lynn; Richardson, Cameron; Jampol, Noah
2014-01-01
To test young children’s false belief theory of mind in a morally relevant context, two experiments were conducted. In Experiment 1, children (N = 162) at 3.5, 5.5, and 7.5 years of age were administered 3 tasks: prototypic moral transgression task, false belief theory of mind task (ToM), and an “accidental transgressor” task, which measured a morally relevant false belief theory of mind (MoToM). Children who did not pass false belief ToM were more likely to attribute negative intentions to an accidental transgressor than children who passed false belief ToM, and to use moral reasons when blaming the accidental transgressor. In Experiment 2, children (N = 46) who did not pass false belief ToM viewed it as more acceptable to punish the accidental transgressor than did participants who passed false belief ToM. Findings are discussed in light of research on the emergence of moral judgment and theory of mind. PMID:21377148
Faber, D.M; Weiland, M.A.; Moursund, R.A.; Carlson, T.J.; Adams, N.; Rondorf, D.
2001-01-01
This report describes tests conducted at Bonneville Dam on the Columbia River in the spring of 2000. The studies used three-dimensional (3D) acoustic telemetry and computational fluid dynamics (CFD) hydraulic modeling techniques to evaluate the response of outmigrating juvenile steelhead (Oncorhynchus mykiss) and yearling chinook (O. tshawytscha) to the Prototype Surface Collector (PSC) installed at Powerhouse I of Bonneville Dam in 1998 to test the concept of using a deep-slot surface bypass collector to divert downstream migrating salmon from turbines. The study was conducted by Pacific Northwest National Laboratory (PNNL), the Waterways Experiment Station of the U.S. Army Corp of Engineers (COE), Asci Corporation, and the U.S. Geological Survey (USGS), and was sponsored by COE’s Portland District. The goal of the study was to observe the three-dimensional behavior of tagged fish (fish bearing ultrasonic micro-transmitters) within 100 meters (m) of the surface flow bypass structure to test hypotheses about the response of migrants to flow stimuli generated by the presence of the surface flow bypass prototype and its operation. Research was done in parallel with radio telemetry studies conducted by USGS and hydroacoustic studies conducted by WES & Asci to evaluate the prototype surface collector.
Schröder, Christian; Steinbrück, Arnd; Müller, Tatjana; Woiczinski, Matthias; Chevalier, Yan; Müller, Peter E.; Jansson, Volkmar
2015-01-01
Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components for in vitro tests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM) by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM) prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE) were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components for in vitro TKA studies and future investigations on knee biomechanics. PMID:25879019
Recent progress on monolithic fiber amplifiers for next generation of gravitational wave detectors
NASA Astrophysics Data System (ADS)
Wellmann, Felix; Booker, Phillip; Hochheim, Sven; Theeg, Thomas; de Varona, Omar; Fittkau, Willy; Overmeyer, Ludger; Steinke, Michael; Weßels, Peter; Neumann, Jörg; Kracht, Dietmar
2018-02-01
Single-frequency fiber amplifiers in MOPA configuration operating at 1064 nm (Yb3+) and around 1550 nm (Er3+ or Er3+:Yb3+) are promising candidates to fulfill the challenging requirements of laser sources of the next generation of interferometric gravitational wave detectors (GWDs). Most probably, the next generation of GWDs is going to operate not only at 1064 nm but also at 1550 nm to cover a broader range of frequencies in which gravitational waves are detectable. We developed an engineering fiber amplifier prototype at 1064 nm emitting 215 W of linearly-polarized light in the TEM00 mode. The system consists of three modules: the seed source, the pre-amplifier, and the main amplifier. The modular design ensures reliable long-term operation, decreases system complexity and simplifies repairing and maintenance procedures. It also allows for the future integration of upgraded fiber amplifier systems without excessive downtimes. We also developed and characterized a fiber amplifier prototype at around 1550 nm that emits 100 W of linearly-polarized light in the TEM00 mode. This prototype uses an Er3+:Yb3+ codoped fiber that is pumped off-resonant at 940 nm. The off-resonant pumping scheme improves the Yb3+-to-Er3+ energy transfer and prevents excessive generation of Yb3+-ASE.
High confidence in falsely recognizing prototypical faces.
Sampaio, Cristina; Reinke, Victoria; Mathews, Jeffrey; Swart, Alexandra; Wallinger, Stephen
2018-06-01
We applied a metacognitive approach to investigate confidence in recognition of prototypical faces. Participants were presented with sets of faces constructed digitally as deviations from prototype/base faces. Participants were then tested with a simple recognition task (Experiment 1) or a multiple-choice task (Experiment 2) for old and new items plus new prototypes, and they showed a high rate of confident false alarms to the prototypes. Confidence and accuracy relationship in this face recognition paradigm was found to be positive for standard items but negative for the prototypes; thus, it was contingent on the nature of the items used. The data have implications for lineups that employ match-to-suspect strategies.
NASA Astrophysics Data System (ADS)
Müller, M.; Graus, M.; Wisthaler, A.; Hansel, A.; Metzger, A.; Dommen, J.; Baltensperger, U.
2011-09-01
A series of 1,3,5-trimethylbenzene (TMB) photo-oxidation experiments was performed in the 27-m3 Paul Scherrer Institute environmental chamber under various NOx conditions. A University of Innsbruck prototype high resolution Proton Transfer Reaction Time-of-Flight Mass Spectrometer (PTR-TOF) was used for measurements of gas and particulate phase organics. The gas phase mass spectrum displayed ~200 ion signals during the TMB photo-oxidation experiments. Molecular formulas CNmHnNoOp were determined and ion signals were separated and grouped according to their C, O and N numbers. This allowed to determine the time evolution of the O:C ratio and of the average carbon oxidation state OSC of the reaction mixture. Both quantities were compared with master chemical mechanism (MCMv3.1) simulations. The O:C ratio in the particle phase was about twice the O:C ratio in the gas phase. Average carbon oxidation states of secondary organic aerosol (SOA) samples OSCSOA were in the range of -0.34 to -0.31, in agreement with expected average carbon oxidation states of fresh SOA (OSC = -0.5 - 0).
NASA Astrophysics Data System (ADS)
Müller, M.; Graus, M.; Wisthaler, A.; Hansel, A.; Metzger, A.; Dommen, J.; Baltensperger, U.
2012-01-01
A series of 1,3,5-trimethylbenzene (TMB) photo-oxidation experiments was performed in the 27-m3 Paul Scherrer Institute environmental chamber under various NOx conditions. A University of Innsbruck prototype high resolution Proton Transfer Reaction Time-of-Flight Mass Spectrometer (PTR-TOF) was used for measurements of gas and particulate phase organics. The gas phase mass spectrum displayed ~200 ion signals during the TMB photo-oxidation experiments. Molecular formulas CmHnNoOp were determined and ion signals were separated and grouped according to their C, O and N numbers. This allowed to determine the time evolution of the O:C ratio and of the average carbon oxidation state OSC of the reaction mixture. Both quantities were compared with master chemical mechanism (MCMv3.1) simulations. The O:C ratio in the particle phase was about twice the O:C ratio in the gas phase. Average carbon oxidation states of secondary organic aerosol (SOA) samples OSCSOA were in the range of -0.34 to -0.31, in agreement with expected average carbon oxidation states of fresh SOA (OSC = -0.5-0).
Design and realization of retina-like three-dimensional imaging based on a MOEMS mirror
NASA Astrophysics Data System (ADS)
Cao, Jie; Hao, Qun; Xia, Wenze; Peng, Yuxin; Cheng, Yang; Mu, Jiaxing; Wang, Peng
2016-07-01
To balance conflicts for high-resolution, large-field-of-view and real-time imaging, a retina-like imaging method based on time-of flight (TOF) is proposed. Mathematical models of 3D imaging based on MOEMS are developed. Based on this method, we perform simulations of retina-like scanning properties, including compression of redundant information and rotation and scaling invariance. To validate the theory, we develop a prototype and conduct relevant experiments. The preliminary results agree well with the simulations.
Development of probabilistic regional climate scenario in East Asia
NASA Astrophysics Data System (ADS)
Dairaku, K.; Ueno, G.; Ishizaki, N. N.
2015-12-01
Climate information and services for Impacts, Adaptation and Vulnerability (IAV) Assessments are of great concern. In order to develop probabilistic regional climate information that represents the uncertainty in climate scenario experiments in East Asia (CORDEX-EA and Japan), the probability distribution of 2m air temperature was estimated by using developed regression model. The method can be easily applicable to other regions and other physical quantities, and also to downscale to finer-scale dependent on availability of observation dataset. Probabilistic climate information in present (1969-1998) and future (2069-2098) climate was developed using CMIP3 SRES A1b scenarios 21 models and the observation data (CRU_TS3.22 & University of Delaware in CORDEX-EA, NIAES AMeDAS mesh data in Japan). The prototype of probabilistic information in CORDEX-EA and Japan represent the quantified structural uncertainties of multi-model ensemble experiments of climate change scenarios. Appropriate combination of statistical methods and optimization of climate ensemble experiments using multi-General Circulation Models (GCMs) and multi-regional climate models (RCMs) ensemble downscaling experiments are investigated.
Chen, Zongwei; Zhang, Qun; Luo, Yi
2018-05-04
An experimental scrutiny of the photoexcited hole dynamics in a prototypical system is presented in which hole-scavenging methanol molecules are chemisorbed on a graphitic carbon nitride (g-C 3 N 4 ) substrate. A set of comparison and control experiments by means of femtosecond time-resolved transient absorption (fs-TA) spectroscopy were conducted. The elusive reverse hole transfer (RHT) process was identified, which occurs on a timescale of a few hundred picoseconds. The critical role of interfacially chemisorbed methoxy (instead of methanol) as the dominant species responsible for hole scavenging was confirmed by a control experiment using protonated g-C 3 N 4 as the substrate. A hot-hole transfer effect was revealed by implementing different interband photoexcitation scenarios. The RHT rate is the key factor governing the hole-scavenging ability of different hole scavengers. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Experiment for search for sterile neutrino at SM-3 reactor
NASA Astrophysics Data System (ADS)
Serebrov, A. P.; Ivochkin, V. G.; Samoylov, R. M.; Fomin, A. K.; Zinoviev, V. G.; Neustroev, P. V.; Golovtsov, V. L.; Gruzinsky, N. V.; Solovey, V. A.; Cherniy, A. V.; Zherebtsov, O. M.; Martemyanov, V. P.; Zinoev, V. G.; Tarasenkov, V. G.; Aleshin, V. I.; Petelin, A. L.; Pavlov, S. V.; Izhutov, A. L.; Sazontov, S. A.; Ryazanov, D. K.; Gromov, M. O.; Afanasiev, V. V.; Matrosov, L. N.; Matrosova, M. Yu.
2016-11-01
In connection with the question of possible existence of sterile neutrino the laboratory on the basis of SM-3 reactor was created to search for oscillations of reactor antineutrino. A prototype of a neutrino detector with scintillator volume of 400 l can be moved at the distance of 6-11 m from the reactor core. The measurements of background conditions have been made. It is shown that the main experimental problem is associated with cosmic radiation background. Test measurements of dependence of a reactor antineutrino flux on the distance from a reactor core have been made. The prospects of search for oscillations of reactor antineutrino at short distances are discussed.
Unger, Bertram J; Kraut, Jay; Rhodes, Charlotte; Hochman, Jordan
2014-01-01
Physical models of complex bony structures can be used for surgical skills training. Current models focus on surface rendering but suffer from a lack of internal accuracy due to limitations in the manufacturing process. We describe a technique for generating internally accurate rapid-prototyped anatomical models with solid and hollow structures from clinical and microCT data using a 3D printer. In a face validation experiment, otolaryngology residents drilled a cadaveric bone and its corresponding printed model. The printed bone models were deemed highly realistic representations across all measured parameters and the educational value of the models was strongly appreciated.
Mobility analysis, simulation, and scale model testing for the design of wheeled planetary rovers
NASA Technical Reports Server (NTRS)
Lindemann, Randel A.; Eisen, Howard J.
1993-01-01
The use of computer based techniques to model and simulate wheeled rovers on rough natural terrains is considered. Physical models of a prototype vehicle can be used to test the correlation of the simulations in scaled testing. The computer approaches include a quasi-static planar or two dimensional analysis and design tool based on the traction necessary for the vehicle to have imminent mobility. The computer program modeled a six by six wheel drive vehicle of original kinematic configuration, called the Rocker Bogie. The Rocker Bogie was optimized using the quasi-static software with respect to its articulation parameters prior to fabrication of a prototype. In another approach used, the dynamics of the Rocker Bogie vehicle in 3-D space was modeled on an engineering workstation using commercial software. The model included the complex and nonlinear interaction of the tire and terrain. The results of the investigation yielded numerical and graphical results of the rover traversing rough terrain on the earth, moon, and Mars. In addition, animations of the rover excursions were also generated. A prototype vehicle was then used in a series of testbed and field experiments. Correspondence was then established between the computer models and the physical model. The results indicated the utility of the quasi-static tool for configurational design, as well as the predictive ability of the 3-D simulation to model the dynamic behavior of the vehicle over short traverses.
A Panel Prototype for the Mu2e Straw Tube Tracker at Fermilab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucà, Alessandra
The Mu2e experiment will search for coherent, neutrino-less conversion of muons into electrons in the Coulomb field of an aluminum nucleus with a sensitivity of four orders of magnitude better than previous experiments. The signature of this process is an electron with energy nearly equal to the muon mass. Mu2e relies on a precision (0.1%) measurement of the outgoing electron momentum to separate signal from background. In order to achieve this goal, Mu2e has chosen a very low-mass straw tracker, made of 20,736 5 mm diameter thin-walled (15more » $$\\mu$$m) Mylar straws, held under tension to avoid the need for supports within the active volume, and arranged in an approximately 3 m long by 0.7 m radius cylinder, operated in vacuum and a 1 T magnetic field. Groups of 96 straws are assembled into modules, called panels. We present the prototype and the assembly procedure for a Mu2e tracker panel built at Fermilab« less
Display technologies for augmented reality
NASA Astrophysics Data System (ADS)
Lee, Byoungho; Lee, Seungjae; Jang, Changwon; Hong, Jong-Young; Li, Gang
2018-02-01
With the virtue of rapid progress in optics, sensors, and computer science, we are witnessing that commercial products or prototypes for augmented reality (AR) are penetrating into the consumer markets. AR is spotlighted as expected to provide much more immersive and realistic experience than ordinary displays. However, there are several barriers to be overcome for successful commercialization of AR. Here, we explore challenging and important topics for AR such as image combiners, enhancement of display performance, and focus cue reproduction. Image combiners are essential to integrate virtual images with real-world. Display performance (e.g. field of view and resolution) is important for more immersive experience and focus cue reproduction may mitigate visual fatigue caused by vergence-accommodation conflict. We also demonstrate emerging technologies to overcome these issues: index-matched anisotropic crystal lens (IMACL), retinal projection displays, and 3D display with focus cues. For image combiners, a novel optical element called IMACL provides relatively wide field of view. Retinal projection displays may enhance field of view and resolution of AR displays. Focus cues could be reconstructed via multi-layer displays and holographic displays. Experimental results of our prototypes are explained.
Chen, Shih-Ching; Hsieh, Tsung-Hsun; Fan, Wen-Jia; Lai, Chien-Hung; Chen, Chun-Lung; Wei, Wei-Feng; Peng, Chih-Wei
2015-06-01
Recent advances in microelectronics and wireless transmission technology have led to the development of various implantable sensors for real-time monitoring of bladder conditions. Although various sensing approaches for monitoring bladder conditions were reported, most such sensors have remained at the laboratory stage due to the existence of vital drawbacks. In the present study, we explored a new concept for monitoring the bladder capacity on the basis of potentiometric principles. A prototype of a potentiometer module was designed and fabricated and integrated with a commercial wireless transmission module and power unit. A series of in vitro pig bladder experiments was conducted to determine the best design parameters for implementing the prototype potentiometric device and to prove its feasibility. We successfully implemented the potentiometric module in a pig bladder model in vitro, and the error of the accuracy of bladder volume detection was <±3%. Although the proposed potentiometric device was built using a commercial wireless module, the design principles and animal experience gathered from this research can serve as a basis for developing new implantable bladder sensors in the future.
NASA Astrophysics Data System (ADS)
Ray, Holly; Biewer, Theodore; Caneses, Juan; Green, Jonathan; Lindquist, Elizabeth; McQuown, Levon; Schmitz, Oliver
2017-10-01
A new helium line-ratio spectral monitoring (HELIOS) diagnostic, using a piezoelectric valve with high duty cycles (on/off times ms), allowing for good background correction, and measured particle flowrates on the order of 1020 particles/second is being implemented on Oak Ridge National Laboratory's (ORNL) Prototype Material Plasma Exposure eXperiment (Proto-MPEX). Built in collaboration with the University of Wisconsin - Madison, the HELIOS diagnostic communicates with a Labview program for controlled bursts of helium into the vessel. The open magnetic geometry of Proto-MPEX is ideal for testing and characterizing a HELIOS diagnostic. The circular cross-section with four ports allows for cross comparison between different diagnostics: 1) Helium injection with the piezoelectric puff valve, 2) HELIOS line-of-sight high-gain observation, 3) scan-able Double Langmuir probe, and 4) HELIOS 2D imaging observation. Electron density and temperature measurements from the various techniques will be compared. This work was supported by the US. D.O.E. contract DE-AC05-00OR22725 and DE-SC00013911.
Integration of real-time 3D capture, reconstruction, and light-field display
NASA Astrophysics Data System (ADS)
Zhang, Zhaoxing; Geng, Zheng; Li, Tuotuo; Pei, Renjing; Liu, Yongchun; Zhang, Xiao
2015-03-01
Effective integration of 3D acquisition, reconstruction (modeling) and display technologies into a seamless systems provides augmented experience of visualizing and analyzing real objects and scenes with realistic 3D sensation. Applications can be found in medical imaging, gaming, virtual or augmented reality and hybrid simulations. Although 3D acquisition, reconstruction, and display technologies have gained significant momentum in recent years, there seems a lack of attention on synergistically combining these components into a "end-to-end" 3D visualization system. We designed, built and tested an integrated 3D visualization system that is able to capture in real-time 3D light-field images, perform 3D reconstruction to build 3D model of the objects, and display the 3D model on a large autostereoscopic screen. In this article, we will present our system architecture and component designs, hardware/software implementations, and experimental results. We will elaborate on our recent progress on sparse camera array light-field 3D acquisition, real-time dense 3D reconstruction, and autostereoscopic multi-view 3D display. A prototype is finally presented with test results to illustrate the effectiveness of our proposed integrated 3D visualization system.
OTF CCSDS Mission Operations Prototype. Directory and Action Service. Phase I: Exit Presentation
NASA Technical Reports Server (NTRS)
Reynolds, Walter F.; Lucord, Steven A.; Stevens, John E.
2009-01-01
This slide presentation describes the phase I directory and action service prototype for the CCSDS system. The project goals are to: (1) Demonstrate the use of Mission Operations standards to implement Directory and Action Services (2) Investigate Mission Operations language neutrality (3) Investigate C3I XML interoperability concepts (4) Integrate applicable open source technologies in a Service Oriented Architecture
Looking the part (to me): effects of racial prototypicality on race perception vary by prejudice
Sprout, Gregory T.; Freeman, Jonathan B.; Krendl, Anne C.
2017-01-01
Abstract Less racially prototypic faces elicit more category competition during race categorization. Top-down factors (e.g. stereotypes), however, affect categorizations, suggesting racial prototypicality may enhance category competition in certain perceivers. Here, we examined how prejudice affects race category competition and stabilization when perceiving faces varying in racial prototypicality. Prototypically low vs high Black relative to White faces elicited more category competition and slower response latencies during categorization (Experiment 1), suggesting a pronounced racial prototypicality effect on minority race categorization. However, prejudice predicted the extent of category competition between prototypically low vs high Black faces. Suggesting more response conflict toward less prototypic Black vs White faces, anterior cingulate cortex activity increased toward Black vs White faces as they decreased in racial prototypicality, with prejudice positively predicting this difference (Experiment 2). These findings extend the literature on racial prototypicality and categorization by showing that relative prejudice tempers the extent of category competition and response conflict engaged when initially perceiving faces. PMID:28077728
Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing
2013-01-01
Background Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930® is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling. Methods The descending aorta anatomy of a volunteer was modelled in 3D from cardiovascular magnetic resonance (CMR) images and rapid prototyped using TangoPlus. The model was printed with a range of increasing wall thicknesses (0.6, 0.7, 0.8, 1.0 and 1.5 mm), keeping the lumen of the vessel constant. Models were also printed in both vertical and horizontal orientations, thus resulting in a total of ten specimens. Compliance tests were performed by monitoring pressure variations while gradually increasing and decreasing internal volume. Knowledge of distensibility was thus derived and then implemented with CMR data to test two applications. Firstly, a patient-specific compliant model of hypoplastic aorta suitable for connection in a mock circulatory loop for in-vitro tests was manufactured. Secondly, the right ventricular outflow tract (RVOT) of a patient necessitating pulmonary valve replacement was printed in order to physically test device insertion and assess patient’s suitability for percutaneous pulmonary valve intervention. Results The distensibility of the material was identified in a range from 6.5 × 10-3 mmHg-1 for the 0.6 mm case, to 3.0 × 10-3 mmHg-1 for the 1.5 mm case. The models printed in the vertical orientation were always more compliant than their horizontal counterpart. Rapid prototyping of a compliant hypoplastic aorta and of a RVOT anatomical model were both feasible. Device insertion in the RVOT model was successful. Conclusion Values of distensibility, compared with literature data, show that TangoPlus is suitable for manufacturing arterial phantoms, with the added benefit of being compatible with PolyJet printing, thus guaranteeing representative anatomical finishing, and quick and inexpensive fabrication. The appealing possibility of printing models of non-uniform wall thickness, resembling more closely certain physiological scenarios, can also be explored. However, this material appears to be too stiff for modelling the more compliant systemic venous system. PMID:23324211
Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing.
Biglino, Giovanni; Verschueren, Peter; Zegels, Raf; Taylor, Andrew M; Schievano, Silvia
2013-01-16
Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930 is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling. The descending aorta anatomy of a volunteer was modelled in 3D from cardiovascular magnetic resonance (CMR) images and rapid prototyped using TangoPlus. The model was printed with a range of increasing wall thicknesses (0.6, 0.7, 0.8, 1.0 and 1.5 mm), keeping the lumen of the vessel constant. Models were also printed in both vertical and horizontal orientations, thus resulting in a total of ten specimens. Compliance tests were performed by monitoring pressure variations while gradually increasing and decreasing internal volume. Knowledge of distensibility was thus derived and then implemented with CMR data to test two applications. Firstly, a patient-specific compliant model of hypoplastic aorta suitable for connection in a mock circulatory loop for in-vitro tests was manufactured. Secondly, the right ventricular outflow tract (RVOT) of a patient necessitating pulmonary valve replacement was printed in order to physically test device insertion and assess patient's suitability for percutaneous pulmonary valve intervention. The distensibility of the material was identified in a range from 6.5 × 10(-3) mmHg(-1) for the 0.6 mm case, to 3.0 × 10(-3) mmHg(-1) for the 1.5 mm case. The models printed in the vertical orientation were always more compliant than their horizontal counterpart. Rapid prototyping of a compliant hypoplastic aorta and of a RVOT anatomical model were both feasible. Device insertion in the RVOT model was successful. Values of distensibility, compared with literature data, show that TangoPlus is suitable for manufacturing arterial phantoms, with the added benefit of being compatible with PolyJet printing, thus guaranteeing representative anatomical finishing, and quick and inexpensive fabrication. The appealing possibility of printing models of non-uniform wall thickness, resembling more closely certain physiological scenarios, can also be explored. However, this material appears to be too stiff for modelling the more compliant systemic venous system.
National preceptor development program (PDP) prototype. The third of a 3-part series.
Cox, Craig D; Mulherin, Katrina; Walter, Sheila
2018-03-01
Preceptor development is critical to successful delivery of experiential learning. Although many preceptor development programs exist, a more individualized approach to training is needed. To accomplish this a national preceptor development program should be considered based on the continuing professional development model. A detailed prototype for this program has been described. In this final installment of the series, the twelve evidence-based recommendations from the first installment were utilized to construct a prototype for a preceptor development program. Over a three-month period, investigators experimented with different designs and models before approving the final prototype. The prototype took the form of an electronic learning platform. Several categories were integral to the design and included sections entitled preceptor spotlight, mentorship, global outreach, choose your own adventure, continuing professional development, feedback, virtual online community, highlights/advertisements, what's new, competency assessment, and frequently asked questions. A graphic was developed to depict the process by which a preceptor would navigate through the web-based learning platform. The authors purposefully maintained a creative and unlimited vision for preceptor development. This conceptual model is intended to spark discussion and augment, refine, or develop entirely innovative ideas to meet preceptor needs. Development of a preceptor development platform could foster improved competency performance, enhanced interest in learning, and promote continuing professional development. With a greater focus on experiential education in pharmacy, the need for a national preceptor development resource is only expected to increase. Copyright © 2017 Elsevier Inc. All rights reserved.
Gorman, Jessica R; Julian, Anne K; Roberts, Samantha A; Romero, Sally A D; Ehren, Jennifer L; Krychman, Michael L; Boles, Sarah G; Mao, Jun; Irene Su, H
2018-02-01
Reproductive-aged breast cancer survivors (BCS) who have completed initial cancer treatment frequently want to know about their future fertility potential. The purpose of this qualitative study was to assess if the fertility-related content presented in the survivorship care plan prototype met the informational needs of post-treatment BCS and to provide an opportunity for the target audience to review and react to the proposed content and design. We conducted and analyzed transcripts from seven focus groups with BCS to evaluate their reactions to the survivorship care plan prototype. We independently coded transcripts for consistent themes and sub-themes and used a consensus-building approach to agree on interpretation of results. We identified five themes that describe the post-treatment BCS' responses to the prototype survivorship care plan in the context of their informational needs and experiences: (1) the prototype's fertility-related information is relevant; (2) desire for clinical parameters to help survivors understand their infertility risk; (3) fertility-related information is important throughout survivorship; (4) evidence-based content from a neutral source is trustworthy; and (5) the recommendation to see a fertility specialist is helpful, but cost is a barrier. BCS have concerns and needs related to their fertility potential after initial breast cancer treatment. The evidence-based information offered in our prototype survivorship care plan was acceptable to BCS and has significant potential to address these needs. Additional primary data that identify post-cancer treatment indicators of fertility would advance this effort.
Egger, Jan; Gall, Markus; Tax, Alois; Ücal, Muammer; Zefferer, Ulrike; Li, Xing; von Campe, Gord; Schäfer, Ute; Schmalstieg, Dieter; Chen, Xiaojun
2017-01-01
In this publication, the interactive planning and reconstruction of cranial 3D Implants under the medical prototyping platform MeVisLab as alternative to commercial planning software is introduced. In doing so, a MeVisLab prototype consisting of a customized data-flow network and an own C++ module was set up. As a result, the Computer-Aided Design (CAD) software prototype guides a user through the whole workflow to generate an implant. Therefore, the workflow begins with loading and mirroring the patients head for an initial curvature of the implant. Then, the user can perform an additional Laplacian smoothing, followed by a Delaunay triangulation. The result is an aesthetic looking and well-fitting 3D implant, which can be stored in a CAD file format, e.g. STereoLithography (STL), for 3D printing. The 3D printed implant can finally be used for an in-depth pre-surgical evaluation or even as a real implant for the patient. In a nutshell, our research and development shows that a customized MeVisLab software prototype can be used as an alternative to complex commercial planning software, which may also not be available in every clinic. Finally, not to conform ourselves directly to available commercial software and look for other options that might improve the workflow.
Egger, Jan; Gall, Markus; Tax, Alois; Ücal, Muammer; Zefferer, Ulrike; Li, Xing; von Campe, Gord; Schäfer, Ute; Schmalstieg, Dieter; Chen, Xiaojun
2017-01-01
In this publication, the interactive planning and reconstruction of cranial 3D Implants under the medical prototyping platform MeVisLab as alternative to commercial planning software is introduced. In doing so, a MeVisLab prototype consisting of a customized data-flow network and an own C++ module was set up. As a result, the Computer-Aided Design (CAD) software prototype guides a user through the whole workflow to generate an implant. Therefore, the workflow begins with loading and mirroring the patients head for an initial curvature of the implant. Then, the user can perform an additional Laplacian smoothing, followed by a Delaunay triangulation. The result is an aesthetic looking and well-fitting 3D implant, which can be stored in a CAD file format, e.g. STereoLithography (STL), for 3D printing. The 3D printed implant can finally be used for an in-depth pre-surgical evaluation or even as a real implant for the patient. In a nutshell, our research and development shows that a customized MeVisLab software prototype can be used as an alternative to complex commercial planning software, which may also not be available in every clinic. Finally, not to conform ourselves directly to available commercial software and look for other options that might improve the workflow. PMID:28264062
Size scaling of negative hydrogen ion sources for fusion
NASA Astrophysics Data System (ADS)
Fantz, U.; Franzen, P.; Kraus, W.; Schiesko, L.; Wimmer, C.; Wünderlich, D.
2015-04-01
The RF-driven negative hydrogen ion source (H-, D-) for the international fusion experiment ITER has a width of 0.9 m and a height of 1.9 m and is based on a ⅛ scale prototype source being in operation at the IPP test facilities BATMAN and MANITU for many years. Among the challenges to meet the required parameters in a caesiated source at a source pressure of 0.3 Pa or less is the challenge in size scaling of a factor of eight. As an intermediate step a ½ scale ITER source went into operation at the IPP test facility ELISE with the first plasma in February 2013. The experience and results gained so far at ELISE allowed a size scaling study from the prototype source towards the ITER relevant size at ELISE, in which operational issues, physical aspects and the source performance is addressed, highlighting differences as well as similarities. The most ITER relevant results are: low pressure operation down to 0.2 Pa is possible without problems; the magnetic filter field created by a current in the plasma grid is sufficient to reduce the electron temperature below the target value of 1 eV and to reduce together with the bias applied between the differently shaped bias plate and the plasma grid the amount of co-extracted electrons. An asymmetry of the co-extracted electron currents in the two grid segments is measured, varying strongly with filter field and bias. Contrary to the prototype source, a dedicated plasma drift in vertical direction is not observed. As in the prototype source, the performance in deuterium is limited by the amount of co-extracted electrons in short as well as in long pulse operation. Caesium conditioning is much harder in deuterium than in hydrogen for which fast and reproducible conditioning is achieved. First estimates reveal a caesium consumption comparable to the one in the prototype source despite the large size.
3D Digitization and Prototyping of the Skull for Practical Use in the Teaching of Human Anatomy.
Lozano, Maria Teresa Ugidos; Haro, Fernando Blaya; Diaz, Carlos Molino; Manzoor, Sadia; Ugidos, Gonzalo Ferrer; Mendez, Juan Antonio Juanes
2017-05-01
The creation of new rapid prototyping techniques, low cost 3D printers as well as the creation of new software for these techniques have allowed the creation of 3D models of bones making their application possible in the field of teaching anatomy in the faculties of Health Sciences. The 3D model of cranium created in the present work, at full scale, present accurate reliefs and anatomical details that are easily identifiable by undergraduate students in their use for the study of human anatomy. In this article, the process of scanning the skull and the subsequent treatment of these images with specific software until the generation of 3D model using 3D printer has been reported.
A Novel Approach For Ankle Foot Orthosis Developed By Three Dimensional Technologies
NASA Astrophysics Data System (ADS)
Belokar, R. M.; Banga, H. K.; Kumar, R.
2017-12-01
This study presents a novel approach for testing mechanical properties of medical orthosis developed by three dimensional (3D) technologies. A hand-held type 3D laser scanner is used for generating 3D mesh geometry directly from patient’s limb. Subsequently 3D printable orthotic design is produced from crude input model by means of Computer Aided Design (CAD) software. Fused Deposition Modelling (FDM) method in Additive Manufacturing (AM) technologies is used to fabricate the 3D printable Ankle Foot Orthosis (AFO) prototype in order to test the mechanical properties on printout. According to test results, printed Acrylonitrile Butadiene Styrene (ABS) AFO prototype has sufficient elasticity modulus and durability for patient-specific medical device manufactured by the 3D technologies.
Parchi, Paolo Domenico; Ferrari, Vincenzo; Piolanti, Nicola; Andreani, Lorenzo; Condino, Sara; Evangelisti, Gisberto; Lisanti, Michele
2013-09-01
Each year approximately 1 million total hip replacements (THR) are performed worldwide. A percentage of failure due to surgical approach and imprecise implant placement still exists. These result in several serious complications. We propose an approach to plan, to simulate, and to assist prosthesis implantation for difficult cases of THR based on 3-D virtual models, generated by segmenting patients' CT images, 3-D solid models, obtained by rapid prototyping (RP), and virtual procedure simulation. We carried out 8 THR with the aid of 3-D reconstruction and RP. After each procedure a questionnaire was submitted to the surgeon to assess the perceived added value of the technology. In all cases, the surgeon evaluated the 3-D model as useful in order to perform the planning. The clinical results showed a mean increase in the Harris Hip Score of about 42.5 points. The mean time of prototyping was 7.3 hours, (min 3.5 hours, max 9.3 hours). The mean surgery time was 65 minutes (min 50 minutes, max 88 minutes). Our study suggests that meticulous preoperative planning is necessary in front of a great aberration of the joint and in absence of normal anatomical landmarks, CT scan is mandatory, and 3-D reconstruction with solid model is useful.
Development of a thermodynamic model for a cold cycle 3He-4He dilution refrigerator
NASA Astrophysics Data System (ADS)
Mueller, B. W.; Miller, F. K.
2016-10-01
A thermodynamic model of a 3He-4He cold cycle dilution refrigerator with no actively-driven mechanical components is developed and investigated. The refrigerator employs a reversible superfluid magnetic pump, passive check valves, a phase separation chamber, and a series of recuperative heat exchangers to continuously circulate 3He-4He and maintain a 3He concentration gradient across the mixing chamber. The model predicts cooling power and mixing chamber temperature for a range of design and operating parameters, allowing an evaluation of feasibility for potential 3He-4He cold cycle dilution refrigerator prototype designs. Model simulations for a prototype refrigerator design are presented.
Early in vivo experience with the pediatric continuous-flow total artificial heart.
Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Kuban, Barry D; Gao, Shengqiang; Dessoffy, Raymond; Fukamachi, Kiyotaka
2018-03-30
Heart transplantation in infants and children is an accepted therapy for end-stage heart failure, but donor organ availability is low and always uncertain. Mechanical circulatory support is another standard option, but there is a lack of intracorporeal devices due to size and functional range. The purpose of this study was to evaluate the in vivo performance of our initial prototype of a pediatric continuous-flow total artificial heart (P-CFTAH), comprising a dual pump with one motor and one rotating assembly, supported by a hydrodynamic bearing. In acute studies, the P-CFTAH was implanted in 4 lambs (average weight: 28.7 ± 2.3 kg) via a median sternotomy under cardiopulmonary bypass. Pulmonary and systemic pump performance parameters were recorded. The experiments showed good anatomical fit and easy implantation, with an average aortic cross-clamp time of 98 ± 18 minutes. Baseline hemodynamics were stable in all 4 animals (pump speed: 3.4 ± 0.2 krpm; pump flow: 2.1 ± 0.9 liters/min; power: 3.0 ± 0.8 W; arterial pressure: 68 ± 10 mm Hg; left and right atrial pressures: 6 ± 1 mm Hg, for both). Any differences between left and right atrial pressures were maintained within the intended limit of ±5 mm Hg over a wide range of ratios of systemic-to-pulmonary vascular resistance (0.7 to 12), with and without pump-speed modulation. Pump-speed modulation was successfully performed to create arterial pulsation. This initial P-CFTAH prototype met the proposed requirements for self-regulation, performance, and pulse modulation. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Konoplev, Oleg A.; Chiragh, Furqan L.; Vasilyev, Aleksey A.; Edwards, Ryan; Stephen, Mark A.; Troupaki, Elisavet; Yu, Anthony W.; Krainak, Michael A.; Sawruk, Nick; Hovis, Floyd; Culpepper, Charles F.; Strickler, Kathy
2016-05-01
We present the results of a three-year operational-aging test of a specially designed prototype flight laser operating at 1064 nm, 10 kHz, 1ns, 15W average power and externally frequency-doubled. Fibertek designed and built the q-switched, 1064nm laser and this laser was in a sealed container of dry air pressurized to 1.3 atm. The external frequency doubler was in a clean room at a normal air pressure. The goal of the experiment was to measure degradation modes at 1064 and 532 nm separately. The external frequency doubler consisted of a Lithium triborate, LiB3O5, non-critically phase-matched crystal. After some 1064 nm light was diverted for diagnostics, 13.7W of fundamental power was available to pump the doubling crystal. Between 8.5W and 10W of 532nm power was generated, depending on the level of stress and degradation. The test consisted of two stages, the first at 0.3 J/cm2 for almost 1 year, corresponding to expected operational conditions, and the second at 0.93 J/cm2 for the remainder of the experiment, corresponding to accelerated optical stress testing. We observed no degradation at the first stress-level and linear degradation at the second stress-level. The linear degradation was linked to doubler crystal output surface changes from laser-assisted contamination. We estimate the expected lifetime for the flight laser at 532 nm using fluence as the stress parameter. This work was done for NASA's Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) LIDAR at Goddard Space Flight Center in Greenbelt, MD with the goal of 1 trillion shots lifetime.
Prototype to measure bracket debonding force in vivo
Tonus, Jéssika Lagni; Manfroi, Fernanda Borguetti; Borges, Gilberto Antonio; Grigolo, Eduardo Correa; Helegda, Sérgio; Spohr, Ana Maria
2017-01-01
ABSTRACT Introduction: Material biodegradation that occurs in the mouth may interfere in the bonding strength between the bracket and the enamel, causing lower bond strength values in vivo, in comparison with in vitro studies. Objective: To develop a prototype to measure bracket debonding force in vivo and to evaluate, in vitro, the bond strength obtained with the prototype. Methods: A original plier (3M Unitek) was modified by adding one strain gauge directly connected to its claw. An electronic circuit performed the reading of the strain gauge, and the software installed in a computer recorded the values of the bracket debonding force, in kgf. Orthodontic brackets were bonded to the facial surface of 30 bovine incisors with adhesive materials. In Group 1 (n = 15), debonding was carried out with the prototype, while tensile bond strength testing was performed in Group 2 (n = 15). A universal testing machine was used for the second group. The adhesive remnant index (ARI) was recorded. Results: According to Student’s t test (α = 0.05), Group 1 (2.96 MPa) and Group 2 (3.08 MPa) were not significantly different. ARI score of 3 was predominant in the two groups. Conclusion: The prototype proved to be reliable for obtaining in vivo bond strength values for orthodontic brackets. PMID:28444011
Xu, Haisong; Zhang, Ce; Shim, Yoong Hoon; Li, Hongliang; Cao, Dejun
2015-03-01
The aim of this study is to discuss the application of rapid-prototyping model and surgical guide in the treatment of mandibular asymmetry malformation with normal occlusal relationship. Twenty-four mandibular asymmetry malformation patients with relatively normal occlusal relationship were included in this study. Surgical 3-dimensional rapid-prototyping mandibular models were made for all patients from the computed tomography (CT) DICOM data. The presurgical plan was designed on the model, and the surgical guiders for the osteotomy lines were manufactured. Genioplasty and/or mandibular osteotomy based on the presurgical plan were performed on these patients with the combined use of the rapid-prototyping model and surgical guides. All patients underwent postoperative CT scan and had at least 3-month follow-up. All patients were satisfied with the final results. According to the postoperative CT images and 3-month follow-up, all patients' mandibular asymmetry malformation was significantly improved, and the operation time was distinctly shortened relative to the conventional method. Rapid-prototyping model and surgical guide are viable auxiliary devices for the treatment of mandibular asymmetry malformation with relatively normal occlusal relationship. Combined use of them can make precise preoperative design, improve effects of operation, and shorten operating time.
Chapter 9 - Vegetation succession modeling for the LANDFIRE Prototype Project
Donald Long; B. John (Jack) Losensky; Donald Bedunah
2006-01-01
One of the main objectives of the Landscape Fire and Resource Management Planning Tools Prototype Project, or LANDFIRE Prototype Project, was to determine departure of current vegetation conditions from the range and variation of conditions that existed during the historical era identified in the LANDFIRE guidelines as 1600-1900 A.D. (Keane and Rollins, Ch. 3). In...
The scientific foundation of the LANDFIRE Prototype Project [Chapter 3
Robert E. Keane; Matthew Rollins
2006-01-01
The Landscape Fire and Resource Management Planning Tools Prototype Project, or LANDFIRE Prototype Project, originated from a recent mapping project that developed a set of coarse-scale spatial data layers for wildland fire management describing fire hazard and ecological status for the conterminous United States (Hardy and others 2001; Schmidt and others 2002; www. fs...
46 CFR 160.135-13 - Approval inspections and tests for prototype lifeboats.
Code of Federal Regulations, 2013 CFR
2013-10-01
...-11 of this subpart; (ii) Assuring that the quality assurance program of the manufacturer is.... (2) Fiber Reinforced Plastic (FRP) prototype lifeboat lay-up. For the prototype of each design of an... non-portable fuel tank must be tested by a static head above the tank top of 3 m (10 ft) of water...
46 CFR 160.135-13 - Approval inspections and tests for prototype lifeboats.
Code of Federal Regulations, 2014 CFR
2014-10-01
...-11 of this subpart; (ii) Assuring that the quality assurance program of the manufacturer is.... (2) Fiber Reinforced Plastic (FRP) prototype lifeboat lay-up. For the prototype of each design of an... non-portable fuel tank must be tested by a static head above the tank top of 3 m (10 ft) of water...
46 CFR 160.135-13 - Approval inspections and tests for prototype lifeboats.
Code of Federal Regulations, 2012 CFR
2012-10-01
...-11 of this subpart; (ii) Assuring that the quality assurance program of the manufacturer is.... (2) Fiber Reinforced Plastic (FRP) prototype lifeboat lay-up. For the prototype of each design of an... non-portable fuel tank must be tested by a static head above the tank top of 3 m (10 ft) of water...
A little-known 3-lens Catadioptric Camera by Bernard Schmidt
NASA Astrophysics Data System (ADS)
Busch, Wolfgang; Ceragioli, Roger C.; Stephani, Walter
2013-07-01
The authors investigate a prototype 3-lens f/1 catadioptric camera, built in 1934 by the famous optician Bernhard Schmidt at the Hamburg-Bergedorf Observatory in Germany, where Schmidt worked before his death in 1935. The prototype is in the observatory's collection of Schmidt artifacts, but its nature was not understood before the authors' recent examination. It is an astronomical camera of a form known as 'Buchroeder-Houghton', consisting of a spherical mirror and a 3-element afocal corrector lens placed at the mirror's center of curvature. The design is named for R.A. Buchroeder and J.L. Houghton who independently published this and related forms of wide-field spherical-lens cameras after 1942. Schmidt died before he could publish his own design. The authors disassembled the prototype and measured its optical parameters. These they present together with a transmission test of the corrector lens. The authors also consider the theoretical performance of the design as built, the theory of Houghton cameras, Schmidt's possible path to his invention, and the place of the prototype in his scientific output.
NASA Astrophysics Data System (ADS)
Klippel, A.; Zhao, J.; Masrur, A.; Wallgruen, J. O.; La Femina, P. C.
2017-12-01
We present work along the virtuality continuum showcasing both AR and VR environments for geoscience applications and research. The AR/VR project focusses on one of the most prominent landmarks on the Penn State campus which, at the same time, is a representation of the geology of Pennsylvania. The Penn State Obelisk is a 32" high, 51 ton monument composed of 281 rocks collected from across Pennsylvania. While information about its origins and composition are scattered in articles and some web databases, we compiled all the available data from the web and archives and curated them as a basis for an immersive xR experience. Tabular data was amended by xR data such as 360° photos, videos, and 3D models (e.g., the Obelisk). Our xR (both AR and VR) prototype provides an immersive analytical environment that supports interactive data visualization and virtual navigation in a natural environment (a campus model of today and of 1896, the year of the Obelisk's installation). This work-in-progress project can provide an interactive immersive learning platform (specifically, for K-12 and introductory level geosciences students) where learning process is enhanced through seamless navigation between 3D data space and physical space. The, second, VR focused application is creating and empirically evaluating virtual reality (VR) experiences for geosciences research, specifically, an interactive volcano experience based on LiDAR and image data of Iceland's Thrihnukar volcano. The prototype addresses the lack of content and tools for immersive virtual reality (iVR) in geoscientific education and research and how to make it easier to integrate iVR into research and classroom experiences. It makes use of environmentally sensed data such that interaction and linked content can be integrated into a single experience. We discuss our workflows as well as methods and authoring tools for iVR analysis and creation of virtual experiences. These methods and tools aim to enhance the utility of geospatial data from repositories such as OpenTopography.org through unlocking treasure-troves of geospatial data for VR applications. Their enhanced accessibility in education and research for the geosciences and beyond will benefit geoscientists and educators who cannot be expected to be VR and 3D application experts.
Nakada, Takeo; Akiba, Tadashi; Inagaki, Takuya; Morikawa, Toshiaki
2014-10-01
Thoracoscopic segmentectomies and subsegmentectomies are more difficult than lobectomy because of the complexity of the procedure; therefore, preoperative decision-making and surgical procedure planning are essential. In the literature, we could successfully perform thoracoscopic anatomical subsegmentectomy of the right S2b + S3 using a 3D printing model with rapid prototyping. This innovative surgical support model is extremely useful for planning a surgical procedure and identifying the surgical margin. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 1 2014-07-01 2014-07-01 false Applicability. 3.3 Section 3.3 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE ACQUISITION TRANSACTIONS OTHER THAN CONTRACTS, GRANTS, OR COOPERATIVE AGREEMENTS FOR PROTOTYPE PROJECTS § 3.3 Applicability. This part applies to the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 1 2013-07-01 2013-07-01 false Applicability. 3.3 Section 3.3 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE ACQUISITION TRANSACTIONS OTHER THAN CONTRACTS, GRANTS, OR COOPERATIVE AGREEMENTS FOR PROTOTYPE PROJECTS § 3.3 Applicability. This part applies to the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 1 2011-07-01 2011-07-01 false Applicability. 3.3 Section 3.3 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE ACQUISITION TRANSACTIONS OTHER THAN CONTRACTS, GRANTS, OR COOPERATIVE AGREEMENTS FOR PROTOTYPE PROJECTS § 3.3 Applicability. This part applies to the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 1 2012-07-01 2012-07-01 false Applicability. 3.3 Section 3.3 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE ACQUISITION TRANSACTIONS OTHER THAN CONTRACTS, GRANTS, OR COOPERATIVE AGREEMENTS FOR PROTOTYPE PROJECTS § 3.3 Applicability. This part applies to the...
Castillo, Venite Pesigan; Sajap, Ahmad Said; Sahri, Mohd Hamami
2013-08-01
Feeding responses of subterranean termites Coptotermes curvignathus (Holmgren) and Coptotermes gestroi (Wasmann) (Blattodea: Rhinotermitidae) to bait matrices supplemented with various sugars, amino acids, and cassava were evaluated both in the laboratory and field. The results indicated that the two termite species consumed significantly different amount of filter papers that had been treated with various types and concentrations of sugars and amino acids. Based on consumption and survival data, filter papers with 3% glucose and 3% xylose were among the most consumed by C. curvignathus and C. gestroi, respectively. Both termite species consumed more of the filter papers treated with 3% casein than filter papers treated with L-alanine. Both species had a comparable survival rate compared with those in the controls. Results from laboratory and field trials on bait prototypes indicated that C. gestroi consumed more bait prototypes containing cellulose, 3% xylose, 3% casein, and cassava, whereas C curvignathus consumed more bait prototype containing cellulose, 3% glucose, and cassava, than on pure crystalline cellulose baits. Thus, with an improved and cost-effective bait formulation, a much wider control of subterranean termite colonies could be achieved.
2014-05-01
Defense Threat Reduction Agency Research and Development Counter WMD Technologies Test Support Division 1680 Texas Street SE Kirtland AFB, NM...Device Prototype Final Report iv | List of Figures List of Figures Figure 3-1. Print screen of the STL file of a hollow microneedle design in Alibre...electrochemical characterization of gold electrode (n = 8) array with oxide dielectric defined working electrodes with 1 mM [Fe(CN)6] 3- in 0.1 M potassium
Trials of prototype roll-feed, high-temperature dryer for 8/4 southern pine
P. Koch
1974-01-01
Eight-foot studs measuring 1.75 by 3.84 inches in cross section were cut from veneer cores and dried in a prototype continuous kiln that provided complete mechanical restraint against warp. Twenty-four hours on a high-temperature schedule brought the pieces from 87.9 to 8.3 percent moisture content without casehardening. Crook, bow, and twist were half that found in...
Evaluation of the Sentinel-3 Hydrologic Altimetry Processor prototypE (SHAPE) methods.
NASA Astrophysics Data System (ADS)
Benveniste, J.; Garcia-Mondéjar, A.; Bercher, N.; Fabry, P. L.; Roca, M.; Varona, E.; Fernandes, J.; Lazaro, C.; Vieira, T.; David, G.; Restano, M.; Ambrózio, A.
2017-12-01
Inland water scenes are highly variable, both in space and time, which leads to a much broader range of radar signatures than ocean surfaces. This applies to both LRM and "SAR" mode (SARM) altimetry. Nevertheless the enhanced along-track resolution of SARM altimeters should help improve the accuracy and precision of inland water height measurements from satellite. The SHAPE project - Sentinel-3 Hydrologic Altimetry Processor prototypE - which is funded by ESA through the Scientific Exploitation of Operational Missions Programme Element (contract number 4000115205/15/I-BG) aims at preparing for the exploitation of Sentinel-3 data over the inland water domain. The SHAPE Processor implements all of the steps necessary to derive rivers and lakes water levels and discharge from Delay-Doppler Altimetry and perform their validation against in situ data. The processor uses FBR CryoSat-2 and L1A Sentinel-3A data as input and also various ancillary data (proc. param., water masks, L2 corrections, etc.), to produce surface water levels. At a later stage, water level data are assimilated into hydrological models to derive river discharge. This poster presents the improvements obtained with the new methods and algorithms over the regions of interest (Amazon and Danube rivers, Vanern and Titicaca lakes).
NASA Astrophysics Data System (ADS)
Bogden, P.; Partners, S.
2008-12-01
The Web 2.0 has helped globalize the economy and change social interactions, but the full impact on coastal sciences has yet to be realized. The SCOOP program (www.OpenIOOS.org/about/sura.html), an initiative of the Coastal Research Committee of the Southeastern Universities Research Association (SURA), has been using Web 2.0 technologies to create infrastructure for a multi-disciplinary Distributed Coastal Laboratory (DCL). In the spirit of the Web 2.0, SCOOP strives to provide an open-access virtual facility where "virtual visiting" scientists can log in, perform experiments (e.g., evaluate new wetting/drying algorithms in several different inundation models), potentially contribute to the assembly of resources (e.g., leave their algorithms for others), and then move on. The SCOOP prototype has focused on storm surge and waves (the initial science focus), and integrates a real-time data network to evaluate the predictions. The multi-purpose SCOOP components support a sensor-web initiative (www.OOSTethys.org) that is co-led by SURA. SCOOP also includes portals with real-time visualization, workflow configuration and decision-tool prototypes (www.OpenIOOS.org), powered by distributed computing resources from multiple universities across the nation (www.sura.org/SURAgrid). Based on our experience, we propose three key ingredients for initiatives to have the biggest impact on coastal science: (1) standards, (2) working prototypes and (3) communities of interest. We strongly endorse the Open Geospatial Consortium - a geospatial analog of the World Wide Web consortium - and other international consensus-standards bodies that engage government, private sector and academic involvement. But these standards are often highly complex, which can be an impediment to their use. We have overcome such hurdles with the second key ingredient: a focused working prototype. The prototype should include guides and resources that make it easy for others to apply, test, and revise the prototype, all without need to understand the standards in their overwhelming complexity. In addition, the prototype should support direct involvement of the third key ingredient: communities of interest that assess functional relevance. We expect that any two of these ingredients alone, without the third, will severely limit applicability and impact of any initiative.
New feature of the neutron color image intensifier
NASA Astrophysics Data System (ADS)
Nittoh, Koichi; Konagai, Chikara; Noji, Takashi; Miyabe, Keisuke
2009-06-01
We developed prototype neutron color image intensifiers with high-sensitivity, wide dynamic range and long-life characteristics. In the prototype intensifier (Gd-Type 1), a terbium-activated Gd 2O 2S is used as the input-screen phosphor. In the upgraded model (Gd-Type 2), Gd 2O 3 and CsI:Na are vacuum deposited to form the phosphor layer, which improved the sensitivity and the spatial uniformity. A europium-activated Y 2O 2S multi-color scintillator, emitting red, green and blue photons with different intensities, is utilized as the output screen of the intensifier. By combining this image intensifier with a suitably tuned high-sensitive color CCD camera, higher sensitivity and wider dynamic range could be simultaneously attained than that of the conventional P20-phosphor-type image intensifier. The results of experiments at the JRR-3M neutron radiography irradiation port (flux: 1.5×10 8 n/cm 2/s) showed that these neutron color image intensifiers can clearly image dynamic phenomena with a 30 frame/s video picture. It is expected that the color image intensifier will be used as a new two-dimensional neutron sensor in new application fields.
The Role of Prototypes in the Mental Representation of Temporally Related Events
ERIC Educational Resources Information Center
Colcombe, Stanley J.; Wyer, Robert S., Jr.
2002-01-01
Four experiments investigated the conditions in which people use a prototypic event sequence to comprehend a situation-specific sequence of events. Results of Experiment 1 confirmed Trafimow and Wyer's (1993) findings that when participants use a prototype (e.g., a cultural script) to comprehend a new sequence of events concerning a hypothetical…
Status of Experiment NEUTRINO-4 Search for Sterile Neutrino
NASA Astrophysics Data System (ADS)
Serebrov, A.; Ivochkin, V.; Samoilov, R.; Fomin, A.; Polyushkin, A.; Zinoviev, V.; Neustroev, P.; Golovtsov, V.; Chernyj, A.; Zherebtsov, O.; Martemyanov, V.; Tarasenkov, V.; Aleshin, V.; Petelin, A.; Izhutov, A.; Tuzov, A.; Sazontov, S.; Ryazanov, D.; Gromov, M.; Afanasiev, V.; Zaytsev, M.; Chaikovskii, M.
2017-01-01
In order to carry out research in the field of possible existence of a sterile neutrino the laboratory based on SM-3 reactor (Dimitrovgrad, Russia) was created to search for oscillations of reactor antineutrino. The prototype of a multi-section neutrino detector with liquid scintillator volume of 350 l was installed in the middle of 2015. It is a moveable inside the passive shielding detector, which can be set at distance range from 6 to 11 meters from the reactor core. Measurements of antineutrino flux at such short distances from the reactor core are carried out with moveable detector for the first time. The measurements with full-scale detector with liquid scintillator volume of 3m3 (5x10 sections) was started only in June, 2016. The today available data is presented in the article.
A wave-bending structure at Ka-band using 3D-printed metamaterial
NASA Astrophysics Data System (ADS)
Wu, Junqiang; Liang, Min; Xin, Hao
2018-03-01
Three-dimensional printing technologies enable metamaterials of complex structures with arbitrary inhomogeneity. In this work, a 90° wave-bending structure at the Ka-band (26.5-40 GHz) based on 3D-printed metamaterials is designed, fabricated, and measured. The wave-bending effect is realized through a spatial distribution of varied effective dielectric constants. Based on the effective medium theory, different effective dielectric constants are accomplished by special, 3D-printable unit cells, which allow different ratios of dielectric to air at the unit cell level. In contrast to traditional, metallic-structure-included metamaterial designs, the reported wave-bending structure here is all dielectric and implemented by the polymer-jetting technique, which features rapid, low-cost, and convenient prototyping. Both simulation and experiment results demonstrate the effectiveness of the wave-bending structure.
Update of GRASP/Ada reverse engineering tools for Ada
NASA Technical Reports Server (NTRS)
Cross, James H., II
1992-01-01
The GRASP/Ada project (Graphical Representations of Algorithms, Structures, and Processes for Ada) has successfully created and prototyped a new algorithmic level graphical representation of Ada software, the Control Structure Diagram (CSD). The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and, as a result, improve reliability and reduce costs. The emphasis was on the automatic generation of the CSD from Ada PDL or source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional prettyprinted Ada source code. In Phase 1 of the GRASP/Ada project, the CSD graphical constructs were created and applied manually to several small Ada programs. A prototype (Version 1) was designed and implemented using FLEX and BISON running under VMS on a VAS 11-780. In Phase 2, the prototype was improved and ported to the Sun 4 platform under UNIX. A user interface was designed and partially implemented using the HP widget toolkit and the X Windows System. In Phase 3, the user interface was extensively reworked using the Athena widget toolkit and X Windows. The prototype was applied successfully to numerous Ada programs ranging in size from several hundred to several thousand lines of source code. Following Phase 3, the prototype was evaluated by software engineering students at Auburn University and then updated with significant enhancements to the user interface including editing capabilities. Version 3.2 of the prototype was prepared for limited distribution to facilitate further evaluation. The current prototype provides the capability for the user to generate CSD's from Ada PDL or source code in a reverse engineering as well as forward engineering mode with a level of flexibility suitable for practical application.
Optimization of Performance Parameters for Large Area Silicon Photomultipliers
NASA Astrophysics Data System (ADS)
Janzen, Kathryn
2008-10-01
The goal of the GlueX experiment is to search for exotic hybrid mesons as evidence of gluonic excitations in an effort to better understand confinement. A key component of the GlueX detector is the electromagnetic barrel calorimeter (BCAL) located immediately inside a superconducting solenoid of approximately 2.5T. Because of this arrangement, traditional vacuum photomultiplier tubes (PMTs) which are affected significantly by magnetic fields cannot be used on the BCAL. The use of Silicon photomultipliers (SiPMs) as front-end detectors has been proposed. While the largest SiPMs that have been previously employed by other experiments are 1x1 mm^2, GlueX proposes to use large area SiPMs each composed of 16 - 3x3 mm^2 cells in a 4x4 array. This puts the GlueX collaboration in the unique position of driving the technology for larger area sensors. In this talk I will discuss tests done in Regina regarding performance parameters of prototype SiPM arrays delivered by SensL, a photonics research and development company based in Ireland, as well as sample 1x1 mm^2 and 3x3 mm^2 SiPMs.
The AMchip04 and the processing unit prototype for the FastTracker
NASA Astrophysics Data System (ADS)
Andreani, A.; Annovi, A.; Beretta, M.; Bogdan, M.; Citterio, M.; Alberti, F.; Giannetti, P.; Lanza, A.; Magalotti, D.; Piendibene, M.; Shochet, M.; Stabile, A.; Tang, J.; Tompkins, L.; Volpi, G.
2012-08-01
Modern experiments search for extremely rare processes hidden in much larger background levels. As the experiment`s complexity, the accelerator backgrounds and luminosity increase we need increasingly complex and exclusive event selection. We present the first prototype of a new Processing Unit (PU), the core of the FastTracker processor (FTK). FTK is a real time tracking device for the ATLAS experiment`s trigger upgrade. The computing power of the PU is such that a few hundred of them will be able to reconstruct all the tracks with transverse momentum above 1 GeV/c in ATLAS events up to Phase II instantaneous luminosities (3 × 1034 cm-2 s-1) with an event input rate of 100 kHz and a latency below a hundred microseconds. The PU provides massive computing power to minimize the online execution time of complex tracking algorithms. The time consuming pattern recognition problem, generally referred to as the ``combinatorial challenge'', is solved by the Associative Memory (AM) technology exploiting parallelism to the maximum extent; it compares the event to all pre-calculated ``expectations'' or ``patterns'' (pattern matching) simultaneously, looking for candidate tracks called ``roads''. This approach reduces to a linear behavior the typical exponential complexity of the CPU based algorithms. Pattern recognition is completed by the time data are loaded into the AM devices. We report on the design of the first Processing Unit prototypes. The design had to address the most challenging aspects of this technology: a huge number of detector clusters (``hits'') must be distributed at high rate with very large fan-out to all patterns (10 Million patterns will be located on 128 chips placed on a single board) and a huge number of roads must be collected and sent back to the FTK post-pattern-recognition functions. A network of high speed serial links is used to solve the data distribution problem.
In-plant testing of membranes to treat electroplating wastewater
NASA Technical Reports Server (NTRS)
Shah, D. B.; Talu, Orhan
1995-01-01
This is the final report submitted for the work performed under the NASA Cooperative Agreement NCC3-301 for the project entitled 'In-Plant Testing of Membranes To Treat Electroplating Waste water'. The main objective of the research project was to determine if the crosslinked polyacrylic acid salt films developed by NASA scientists could be used for heavy metal removal from the wastewater generated by the metals-finishing or electroplating industry. A variety of tasks identified in the original proposal were completed. These included: (1) analysis of our industrial partner Aetna Plating's zinc electroplating process and its wastewater treatment needs for zinc removal; (2) design and construction of a laboratory-scale unit to continuously supply and remove the ion exchange films from the zinc wastewater; (3) performance of a series of runs on such a unit to determine its operating characteristics; and (4) design of a prototype unit for use at the industrial site. In addition, there were a number of tasks that had not been identified in the original proposal but were later judged to be necessary for the successful completion of the project. These were: (1) batch equilibrium and kinetic experiments with analysis of the experimental results to accurately determine the equilibrium and kinetic parameters for the ion exchange films; (2 ) simulation studies for proper design of the prototype unit; and (3) preliminary runs to exchange the films from H form to Calcium form.
42. ARAIII Prototype assembly and evaluation building ARA630 interior. Typical ...
42. ARA-III Prototype assembly and evaluation building ARA-630 interior. Typical view room partitions. Ineel photo no. 3-28. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
Silicon Drift Detectors - A Novel Technology for Vertex Detectors
NASA Astrophysics Data System (ADS)
Lynn, D.
1996-10-01
Silicon Drift Detectors (SDD) are novel position sensing silicon detectors which operate in a manner analogous to gas drift detectors. Single SDD's were shown in the CERN NA45 experiment to permit excellent spatial resolution (< 10 μm), to handle large particle occupancy, and to require a small fraction of the number of electronic channels of an equivalent pixel detector. The Silicon Vertex Tracker (SVT) for the STAR experiment at RHIC is based on this new technology. The SVT will consist of 216 SDD's, each 6.3 cm by 6.3 cm, arranged in a three layer barrel design, covering 2 π in azimuth and ±1 in pseudo-rapidity. Over the last three years we undertook a concentrated R+D effort to optimize the performance of the detector by minimizing the inactive area, the operating voltage and the data volume. We will present test results from several wafer prototypes. The charge produced by the passage of ionizing particles through the bulk of the detectors is collected on segmented anodes, with a pitch of 250 μm, on the far edges of the detector. The anodes are wire-bonded to a thick film multi-chip module which contains preamplifier/shaper chips and CMOS based switched capacitor arrays used as an analog memory pipeline. The ADC is located off-detector. The complete readout chain from the wafer to the DAQ will be presented. Finally we will show physics performance simulations based on the resolution achieved by the SVT prototypes.
NASA Technical Reports Server (NTRS)
Coyle, D. Barry; Kay, Richard B.; Degnan, John J.; Krebs, Danny J.; Seery, Bernard D.
1992-01-01
A small, all solid state, regenerative ring amplifier designed as a prototype for space application is discussed. Novel features include dual side pumping of the Nd:YAG crystal and a triangular ring cavity design which minimizes the number of optical components and losses. The amplifier is relatively small (3 ns round trip time) even though standard optical elements are employed. The ring regeneratively amplifies a 100 ps single pulse by approximately 10(exp 5) at a repetition rate of 10 to 100 Hz. The amplifier is designed to be injection seeded with a pulsed, 100 ps laser diode at 1.06 microns, but another Nd:YAG laser system supplying higher pulse energies was employed for laboratory experiment. This system is a prototype laser oscillator for the Geoscience Laser Ranging System (GLRS) platform. Results on measurements of beam quality, astigmatism, and gain are given.
Design and prototype studies of the TOTEM Roman pot detectors
NASA Astrophysics Data System (ADS)
Oriunno, Marco; Battistin, Michele; David, Eric; Guglielmini, Paolo; Joram, Christian; Radermacher, Ernst; Ruggiero, Gennaro; Wu, Jihao; Vacek, Vaclav; Vins, Vaclav
2007-10-01
The Roman pots of the TOTEM experiment at LHC will be equipped with edgeless silicon micro-strip detectors. A detector package consists of 10 detector planes cooled at -15C in vacuum. The detector resolution is 20 μm, the overall alignment precision has to be better than 30 μm. The detector planes are composed of a kapton hybrid glued on a substrate made of low expansion alloy, CE07 with 70% Si and 30% Al. An evaporative cooling system based on the fluorocarbon C3F8 with oil-free compressors has been adopted. The throttling of the fluid is done locally through capillaries. A thermo-mechanical prototype has been assembled. The results fully match the requirements and the expectations of calculations. They show a low thermal gradient on the cards and a uniform temperature distribution over the 10 planes.
Micro sculpting technology using DPSSL
NASA Astrophysics Data System (ADS)
Chang, Won-Seok; Shin, Bosung; Kim, Jae-gu; Whang, Kyung-Hyun
2003-11-01
Multiple pulse laser ablation of polymer is performed with DPSS (Diode Pumped Solid State) 3rd harmonic Nd:YVO4 laser (355 nm) in order to fabricate three-dimensional micro components. Here we considered mechanistic aspects of the interaction between UV laser and polymer to obtain optimum process conditions for maskless photomachining using DPSSL. The photo-physical and photochemical parameters such as laser wavelength and optical characteristics of polymers are investigated by experiments to reduce plume effect, which induce the re-deposited debris on the surface of substrate. In this study, LDST (laser direct sculpting technique) are developed to gain various three-dimensional shape with size less than 500 micrometer. Main process sequences are from rapid prototyping technology such as CAD/CAM modeling of products, machining path generation, layer-by-layer machining, and so on. This method can be applied to manufacture the prototype of micro device and the polymer mould for mass production without expensive mask fabrication.
Control and Guidance of Low-Cost Robots via Gesture Perception for Monitoring Activities in the Home
Sempere, Angel D.; Serna-Leon, Arturo; Gil, Pablo; Puente, Santiago; Torres, Fernando
2015-01-01
This paper describes the development of a low-cost mini-robot that is controlled by visual gestures. The prototype allows a person with disabilities to perform visual inspections indoors and in domestic spaces. Such a device could be used as the operator's eyes obviating the need for him to move about. The robot is equipped with a motorised webcam that is also controlled by visual gestures. This camera is used to monitor tasks in the home using the mini-robot while the operator remains quiet and motionless. The prototype was evaluated through several experiments testing the ability to use the mini-robot’s kinematics and communication systems to make it follow certain paths. The mini-robot can be programmed with specific orders and can be tele-operated by means of 3D hand gestures to enable the operator to perform movements and monitor tasks from a distance. PMID:26690448
Magnetoimpedance biosensor prototype for ferrogel detection
NASA Astrophysics Data System (ADS)
Kurlyandskaya, G. V.; Fernández, E.; Safronov, A. P.; Blyakhman, F. A.; Svalov, A. V.; Burgoa Beitia, A.; Beketov, I. V.
2017-11-01
Ferrogels are composite materials widely introduced in the area of biomedical engineering as magnetic field sensitive transformers. These biomimetic materials can be prepared by incorporating monodomain magnetic nanoparticles into chemically crosslinked hydrogels. The properties of a biomimetic ferrogels taken for the study unlike that of the biological prototype might be set up by the synthesis and can be thoroughly controlled in a physical experiment. In this work we developed a giant magnetoimpedance sensor with a multilayered FeNi/Ti-based sensitive element adapted for ferrogel studies. Ferrogels were synthesized by radical polymerization of acrylamide in a stable aqueous suspension of γ-Fe2O3 MNPs fabricated by laser target evaporation. The magnetoimpedance measurements in initial state and in the presence of ferrogels with concentrations of nanoparticles from 0 to 2.4 wt% in a frequency range of 1-300 MHz allowed a precise characterization of the stray fields of the nanoparticles present in the ferrogel.
10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Alternative § 434.504 Use of the prototype building to determine the energy cost budget. 504.1Determine the... 10 Energy 3 2012-01-01 2012-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...
10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Alternative § 434.504 Use of the prototype building to determine the energy cost budget. 504.1Determine the... 10 Energy 3 2011-01-01 2011-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...
10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Alternative § 434.504 Use of the prototype building to determine the energy cost budget. 504.1 Determine the... 10 Energy 3 2014-01-01 2014-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...
10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Alternative § 434.504 Use of the prototype building to determine the energy cost budget. 504.1Determine the... 10 Energy 3 2013-01-01 2013-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...
Organic Binder Developments for Solid Freeform Fabrication
NASA Technical Reports Server (NTRS)
Cooper, Ken; Mobasher, Amir A.
2003-01-01
A number of rapid prototyping techniques are under development at Marshall Space Flight Center's (MSFC) National Center for Advanced Manufacturing Rapid Prototyping Laboratory. Commercial binder developments in creating solid models for rapid prototyping include: 1) Fused Deposition Modeling; 2) Three Dimensional Printing; 3) Selective Laser Sintering (SLS). This document describes these techniques developed by the private sector, as well as SLS undertaken by MSFC.
Looking the part (to me): effects of racial prototypicality on race perception vary by prejudice.
Cassidy, Brittany S; Sprout, Gregory T; Freeman, Jonathan B; Krendl, Anne C
2017-04-01
Less racially prototypic faces elicit more category competition during race categorization. Top-down factors (e.g. stereotypes), however, affect categorizations, suggesting racial prototypicality may enhance category competition in certain perceivers. Here, we examined how prejudice affects race category competition and stabilization when perceiving faces varying in racial prototypicality. Prototypically low vs high Black relative to White faces elicited more category competition and slower response latencies during categorization (Experiment 1), suggesting a pronounced racial prototypicality effect on minority race categorization. However, prejudice predicted the extent of category competition between prototypically low vs high Black faces. Suggesting more response conflict toward less prototypic Black vs White faces, anterior cingulate cortex activity increased toward Black vs White faces as they decreased in racial prototypicality, with prejudice positively predicting this difference (Experiment 2). These findings extend the literature on racial prototypicality and categorization by showing that relative prejudice tempers the extent of category competition and response conflict engaged when initially perceiving faces. © The Author (2017). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Yoshida, Kazuya; Hirose, Shigeo; Ogawa, Tadashi
1994-01-01
The establishment of those in-orbit operations like 'Rendez-Vous/Docking' and 'Manipulator Berthing' with the assistance of robotics or autonomous control technology, is essential for the near future space programs. In order to study the control methods, develop the flight models, and verify how the system works, we need a tool or a testbed which enables us to simulate mechanically the micro-gravity environment. There have been many attempts to develop the micro-gravity testbeds, but once the simulation goes into the docking and berthing operation that involves mechanical contacts among multi bodies, the requirement becomes critical. A group at the Tokyo Institute of Technology has proposed a method that can simulate the 3D micro-gravity producing a smooth response to the impact phenomena with relatively simple apparatus. Recently the group carried out basic experiments successfully using a prototype hardware model of the testbed. This paper will present our idea of the 3D micro-gravity simulator and report the results of our initial experiments.
Jiang, C Y; Tong, X; Brown, D R; Glavic, A; Ambaye, H; Goyette, R; Hoffmann, M; Parizzi, A A; Robertson, L; Lauter, V
2017-02-01
Modern spallation neutron sources generate high intensity neutron beams with a broad wavelength band applied to exploring new nano- and meso-scale materials from a few atomic monolayers thick to complicated prototype device-like systems with multiple buried interfaces. The availability of high performance neutron polarizers and analyzers in neutron scattering experiments is vital for understanding magnetism in systems with novel functionalities. We report the development of a new generation of the in situ polarized 3 He neutron polarization analyzer for the Magnetism Reflectometer at the Spallation Neutron Source at Oak Ridge National Laboratory. With a new optical layout and laser system, the 3 He polarization reached and maintained 84% as compared to 76% in the first-generation system. The polarization improvement allows achieving the transmission function varying from 50% to 15% for the polarized neutron beam with the wavelength band of 2-9 Angstroms. This achievement brings a new class of experiments with optimal performance in sensitivity to very small magnetic moments in nano systems and opens up the horizon for its applications.
Three-dimensional (3D) printing and its applications for aortic diseases.
Hangge, Patrick; Pershad, Yash; Witting, Avery A; Albadawi, Hassan; Oklu, Rahmi
2018-04-01
Three-dimensional (3D) printing is a process which generates prototypes from virtual objects in computer-aided design (CAD) software. Since 3D printing enables the creation of customized objects, it is a rapidly expanding field in an age of personalized medicine. We discuss the use of 3D printing in surgical planning, training, and creation of devices for the treatment of aortic diseases. 3D printing can provide operators with a hands-on model to interact with complex anatomy, enable prototyping of devices for implantation based upon anatomy, or even provide pre-procedural simulation. Potential exists to expand upon current uses of 3D printing to create personalized implantable devices such as grafts. Future studies should aim to demonstrate the impact of 3D printing on outcomes to make this technology more accessible to patients with complex aortic diseases.
Spectral performance of Square Kilometre Array Antennas - II. Calibration performance
NASA Astrophysics Data System (ADS)
Trott, Cathryn M.; de Lera Acedo, Eloy; Wayth, Randall B.; Fagnoni, Nicolas; Sutinjo, Adrian T.; Wakley, Brett; Punzalan, Chris Ivan B.
2017-09-01
We test the bandpass smoothness performance of two prototype Square Kilometre Array (SKA) SKA1-Low log-periodic dipole antennas, SKALA2 and SKALA3 ('SKA Log-periodic Antenna'), and the current dipole from the Murchison Widefield Array (MWA) precursor telescope. Throughout this paper, we refer to the output complex-valued voltage response of an antenna when connected to a low-noise amplifier, as the dipole bandpass. In Paper I, the bandpass spectral response of the log-periodic antenna being developed for the SKA1-Low was estimated using numerical electromagnetic simulations and analysed using low-order polynomial fittings, and it was compared with the HERA antenna against the delay spectrum metric. In this work, realistic simulations of the SKA1-Low instrument, including frequency-dependent primary beam shapes and array configuration, are used with a weighted least-squares polynomial estimator to assess the ability of a given prototype antenna to perform the SKA Epoch of Reionisation (EoR) statistical experiments. This work complements the ideal estimator tolerances computed for the proposed EoR science experiments in Trott & Wayth, with the realized performance of an optimal and standard estimation (calibration) procedure. With a sufficient sky calibration model at higher frequencies, all antennas have bandpasses that are sufficiently smooth to meet the tolerances described in Trott & Wayth to perform the EoR statistical experiments, and these are primarily limited by an adequate sky calibration model and the thermal noise level in the calibration data. At frequencies of the Cosmic Dawn, which is of principal interest to SKA as one of the first next-generation telescopes capable of accessing higher redshifts, the MWA dipole and SKALA3 antenna have adequate performance, while the SKALA2 design will impede the ability to explore this era.
Ethylene vinyl acetate (EVA) as a new drug carrier for 3D printed medical drug delivery devices.
Genina, Natalja; Holländer, Jenny; Jukarainen, Harri; Mäkilä, Ermei; Salonen, Jarno; Sandler, Niklas
2016-07-30
The main purpose of this work was to investigate the printability of different grades of ethylene vinyl acetate (EVA) copolymers as new feedstock material for fused-deposition modeling (FDM™)-based 3D printing technology in fabrication of custom-made T-shaped intrauterine systems (IUS) and subcutaneous rods (SR). The goal was to select an EVA grade with optimal properties, namely vinyl acetate content, melting index, flexural modulus, for 3D printing of implantable prototypes with the drug incorporated within the entire matrix of the medical devices. Indomethacin was used as a model drug in this study. Out of the twelve tested grades of the EVA five were printable. One of them showed superior print quality and was further investigated by printing drug-loaded filaments, containing 5% and 15% indomethacin. The feedstock filaments were fabricated by hot-melt extrusion (HME) below the melting point of the drug substance and the IUS and SR were successfully printed at the temperature above the melting point of the drug. As a result, the drug substance in the printed prototypes showed to be at least partly amorphous, while the drug in the corresponding HME filaments was crystalline. This difference affected the drug release profiles from the filaments and printed prototype products: faster release from the prototypes over 30days in the in vitro tests. To conclude, this study indicates that certain grades of EVA were applicable feedstock material for 3D printing to produce drug-loaded implantable prototypes. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Bi, Siwen; Zhen, Ming; Yang, Song; Lin, Xuling; Wu, Zhiqiang
2017-08-01
According to the development and application needs of Remote Sensing Science and technology, Prof. Siwen Bi proposed quantum remote sensing. Firstly, the paper gives a brief introduction of the background of quantum remote sensing, the research status and related researches at home and abroad on the theory, information mechanism and imaging experiments of quantum remote sensing and the production of principle prototype.Then, the quantization of pure remote sensing radiation field, the state function and squeezing effect of quantum remote sensing radiation field are emphasized. It also describes the squeezing optical operator of quantum light field in active imaging information transmission experiment and imaging experiments, achieving 2-3 times higher resolution than that of coherent light detection imaging and completing the production of quantum remote sensing imaging prototype. The application of quantum remote sensing technology can significantly improve both the signal-to-noise ratio of information transmission imaging and the spatial resolution of quantum remote sensing .On the above basis, Prof.Bi proposed the technical solution of active imaging information transmission technology of satellite borne quantum remote sensing, launched researches on its system composition and operation principle and on quantum noiseless amplifying devices, providing solutions and technical basis for implementing active imaging information technology of satellite borne Quantum Remote Sensing.
NASA Controller Acceptability Study 1(CAS-1) Experiment Description and Initial Observations
NASA Technical Reports Server (NTRS)
Chamberlain, James P.; Consiglio, Maria C.; Comstock, James R., Jr.; Ghatas, Rania W.; Munoz, Cesar
2015-01-01
This paper describes the Controller Acceptability Study 1 (CAS-1) experiment that was conducted by NASA Langley Research Center personnel from January through March 2014 and presents partial CAS-1 results. CAS-1 employed 14 air traffic controller volunteers as research subjects to assess the viability of simulated future unmanned aircraft systems (UAS) operating alongside manned aircraft in moderate-density, moderate-complexity Class E airspace. These simulated UAS were equipped with a prototype pilot-in-the-loop (PITL) Detect and Avoid (DAA) system, specifically the Self-Separation (SS) function of such a system based on Stratway+ software to replace the see-and-avoid capabilities of manned aircraft pilots. A quantitative CAS-1 objective was to determine horizontal miss distance (HMD) values for SS encounters that were most acceptable to air traffic controllers, specifically HMD values that were assessed as neither unsafely small nor disruptively large. HMD values between 0.5 and 3.0 nautical miles (nmi) were assessed for a wide array of encounter geometries between UAS and manned aircraft. The paper includes brief introductory material about DAA systems and their SS functions, followed by descriptions of the CAS-1 simulation environment, prototype PITL SS capability, and experiment design, and concludes with presentation and discussion of partial CAS-1 data and results.
Prototype solar heating and cooling systems
NASA Technical Reports Server (NTRS)
1978-01-01
Eight prototype systems were developed. The systems are 3, 25, and 75-ton size units. The manufacture, test, installation, maintenance, problem resolution, and performance evaluation of the systems is described. Size activities for the various systems are included.
Design and Prototyping of a Satellite Antenna Slew Testbed
2013-12-01
polycarbonate plastic PC personal computer PD proportional derivative PDO process data objects PVC polyvinyl chloride PVT position...part. The CAD model of the current design iteration can be exported to 3D printer to produce a plastic prototype of the testbed assembly. The 3D... extruded shaft) and connected by set screws as shown in Figure 8. The set screws translate the force from motor to gears to shaft, thus creating an
Asendorpf, J B; van Aken, M A
1999-10-01
In a longitudinal study, Q-sort patterns of German preschool children were analyzed for personality prototypes and related to developmental outcomes up to age 12. Q-factor analyses confirmed 3 prototypic patterns that showed a high continuity and cross-judge consistency; were similar to those found for North American, Dutch, and Icelandic children; and can be interpreted as resilient, overcontrolled, and undercontrolled. Relations reported by R. W. Robins, O. P. John, A. Caspi, T. E. Moffitt, & M. Stouthamer-Loeber (1996) between these 3 patterns and the Big Five were fully replicated. Growth curve analyses showed that the 3 patterns predicted important developmental outcomes in both the social and the cognitive domains. Evidence was found for both traits and types: A continuous dimension of resiliency bifurcates in its lower part into two relatively discrete personality types, overcontrollers and undercontrollers.
Design Principles for Rapid Prototyping Forces Sensors using 3D Printing.
Kesner, Samuel B; Howe, Robert D
2011-07-21
Force sensors provide critical information for robot manipulators, manufacturing processes, and haptic interfaces. Commercial force sensors, however, are generally not adapted to specific system requirements, resulting in sensors with excess size, cost, and fragility. To overcome these issues, 3D printers can be used to create components for the quick and inexpensive development of force sensors. Limitations of this rapid prototyping technology, however, require specialized design principles. In this paper, we discuss techniques for rapidly developing simple force sensors, including selecting and attaching metal flexures, using inexpensive and simple displacement transducers, and 3D printing features to aid in assembly. These design methods are illustrated through the design and fabrication of a miniature force sensor for the tip of a robotic catheter system. The resulting force sensor prototype can measure forces with an accuracy of as low as 2% of the 10 N measurement range.
NASA Technical Reports Server (NTRS)
Cath, Tzahi Y.; Adams, Dean V.; Childress, Amy; Gormly, Sherwin; Flynn, Michael
2005-01-01
Direct osmotic concentration (DOC) has been identified as a high potential technology for recycling of wastewater to drinking water in advanced life support (ALS) systems. As a result the DOC process has been selected for a NASA Rapid Technology Development Team (RTDT) effort. The existing prototype system has been developed to a Technology Readiness Level (TRL) 3. The current project focuses on advancing the development of this technology from TRL 3 to TRL 6 (appropriate for human rated testing). A new prototype of a DOC system is been designed and fabricated that addresses the deficiencies encountered during the testing of the original system and allowing the new prototype to achieve TRL 6. Background information is provided about the technologies investigated and their capabilities, results from preliminary tests, and the milestones plan and activities for the RTDT program intended to develop a second generation prototype of the DOC system.
2013-01-01
PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) RAND...prototype model illustrating concretely a new approach. The prototype model itself should be seen not as a definitive end point, but rather as a...9 1 4 8 1 4 8 1 1 1 1 2 2 1 2 2 2 8 9 2 8 9 3 9 9 2 8 8 2 8 9 2 9 9 1 1 3 1 2 4 1 2 4 xviii A Computational Model of Public Support for Insurgency
A pilot biomedical engineering course in rapid prototyping for mobile health.
Stokes, Todd H; Venugopalan, Janani; Hubbard, Elena N; Wang, May D
2013-01-01
Rapid prototyping of medically assistive mobile devices promises to fuel innovation and provides opportunity for hands-on engineering training in biomedical engineering curricula. This paper presents the design and outcomes of a course offered during a 16-week semester in Fall 2011 with 11 students enrolled. The syllabus covered a mobile health design process from end-to-end, including storyboarding, non-functional prototypes, integrated circuit programming, 3D modeling, 3D printing, cloud computing database programming, and developing patient engagement through animated videos describing the benefits of a new device. Most technologies presented in this class are open source and thus provide unlimited "hackability". They are also cost-effective and easily transferrable to other departments.
NASA Technical Reports Server (NTRS)
Ordaz, Miguel Angel
1997-01-01
The University of Texas at El Paso (UTEP) in conjunction with the Jet Propulsion Laboratory (JPL), North Carolina A&T and California State University of Los Angeles participated during the summer of 1996 in a prototype program known as Minority University Systems Engineering (MUSE). The program consisted of a ten week internship at JPL for students and professors of the three universities. The purpose of MUSE as set forth in the MUSE program review August 5, 1996 was for the participants to gain experience in the following areas: 1) Gain experience in a multi-disciplinary project; 2) Gain experience working in a culturally diverse atmosphere; 3) Provide field experience for students to reinforce book learning; and 4) Streamline the design process in two areas: make it more financially feasible; and make it faster.
NASA Astrophysics Data System (ADS)
Angeletaki, A.; Carrozzino, M.; Johansen, S.
2013-07-01
In this paper we present an experimental environment of 3D books combined with a game application that has been developed by a collaboration project between the Norwegian University of Science and Technology in Trondheim, Norway the NTNU University Library, and the Percro laboratory of Santa Anna University in Pisa, Italy. MUBIL is an international research project involving museums, libraries and ICT academy partners aiming to develop a consistent methodology enabling the use of Virtual Environments as a metaphor to present manuscripts content through the paradigms of interaction and immersion, evaluating different possible alternatives. This paper presents the results of the application of two prototypes of books augmented with the use of XVR and IL technology. We explore immersive-reality design strategies in archive and library contexts for attracting new users. Our newly established Mubil-lab has invited school classes to test the books augmented with 3D models and other multimedia content in order to investigate whether the immersion in such environments can create wider engagement and support learning. The metaphor of 3D books and game designs in a combination allows the digital books to be handled through a tactile experience and substitute the physical browsing. In this paper we present some preliminary results about the enrichment of the user experience in such environment.
Selective laser sintering of single-phase powder Cr-V tool steel
NASA Astrophysics Data System (ADS)
Kovalev, A. I.; Mishina, V. P.; Wainstein, D. L.; Titov, V. I.; Moiseev, V. F.; Tolochko, N. K.
2002-10-01
Presented is positive experience from selective laser sintering (SLS) of cylindrical steel specimens (3.0% C, 3.0% Cr, 1.0% Si, 12.0% V, Fe balance) 30 mm long and 5 mm in diameter by rapid prototyping. It was demonstrated that monolithic steel material could be successfully fabricated by this technology. Differential thermal analysis (DTA), scanning electron microscopy (SEM), and x-ray diffractometry (XRD) were used to study the microstructure, phase, and chemical composition of the source material and obtained specimens. Low-melting cementite-based eutectic was found to provide the liquid phase sintering of powder tool steel. The porosity of the green sintered specimens did not exceed 5%. The mean hardness value of sintered specimens was 825 HV.
NASA Astrophysics Data System (ADS)
Yerizon; Jazwinarti; Yarman
2018-01-01
Students have difficulties experience in the course Introduction to Operational Research (PRO). The purpose of this study is to analyze the requirement of students in the developing lecturing materials PRO based Problem Based Learning which is valid, practice, and effective. Lecture materials are developed based on Plomp’s model. The development process of this device consists of 3 phases: front-end analysis/preliminary research, development/prototype phase and assessment phase. Preliminary analysis was obtained by observation and interview. From the research, it is found that students need the student’s worksheet (LKM) for several reasons: 1) no LKM available, 2) presentation of subject not yet based on real problem, 3) experiencing difficulties from current learning source.
NASA Astrophysics Data System (ADS)
Lestantri, I. D.; Putrima; Sabiq, A.; Suherlan, E.
2018-03-01
Indonesia is the country number 4 as the largest smartphone user. In addition to functioning as a social media, the use of smartphones for other purposes has begun to develop in order to facilitate the work. Similarly in the field of maternal and child health. Most of the public, pregnant mothers and checking the development of children under five, were conducted to the Public Health Center. As a service center, Public Health Center need to improve its services. Among other things, it needs to be supported with technology. The high number of queues, the length of queue time and the traffic jam, prompted the need for the development of health applications, based on mobile. The role of the user is crucial to the successful implementation of a technology. This study aims to measure whether the application of M-Health Care application, as a prototype of the application developed to meet the needs of users. M-Health Care Application was developed with a prototyping approach. While for the measurement of M-Health Care Application done by using approach of USE Questionnaire. From result of data processing got result, usability measurement value equal to 88,3%. This indicates the M-Health Care application prototype is considered satisfactory for the user.The results of this measurement can be used as a reference for the next M-Health Care application development model based on user experience.
Bill, J S; Reuther, J F
2004-05-01
The aim was to define the indications for use of rapid prototyping models based on data of patients treated with this technique. Since 1987 our department has been developing methods of rapid prototyping in surgery planning. During the study, first the statistical and reproducible anatomical precision of rapid prototyping models was determined on pig skull measurements depending on CT parameters and method of rapid prototyping. Measurements on stereolithography models and on selective laser sintered models confirmed an accuracy of +/-0.88 mm or 2.7% (maximum deviation: -3.0 mm to +3.2 mm) independently from CT parameters or method of rapid prototyping, respectively. With the same precision of models multilayer helical CT with a higher rate is the preferable method of data acquisition compared to conventional helical CT. From 1990 to 2002 in atotal of 122 patients, 127 rapid prototyping models were manufactured: in 112 patients stereolithography models, in 2 patients an additional stereolithography model, in 2 patients an additional selective laser sinter model, in 1 patient an additional milled model, and in 10 patients just a selective laser sinter model. Reconstructive surgery, distraction osteogenesis including midface distraction, and dental implantology are proven to be the major indications for rapid prototyping as confirmed in a review of the literature. Surgery planning on rapid prototyping models should only be used in individual cases due to radiation dose and high costs. Routine use of this technique only seems to be indicated in skull reconstruction and distraction osteogenesis.
A novel manipulation method of human body ownership using an fMRI-compatible master-slave system.
Hara, Masayuki; Salomon, Roy; van der Zwaag, Wietske; Kober, Tobias; Rognini, Giulio; Nabae, Hiroyuki; Yamamoto, Akio; Blanke, Olaf; Higuchi, Toshiro
2014-09-30
Bodily self-consciousness has become an important topic in cognitive neuroscience aiming to understand how the brain creates a unified sensation of the self in a body. Specifically, full body illusion (FBI) in which changes in bodily self-consciousness are experimentally introduced by using visual-tactile stimulation has led to improve understanding of these mechanisms. This paper introduces a novel approach to the classic FBI paradigm using a robotic master-slave system which allows us to examine interactions between action and the sense of body ownership in behavioral and MRI experiments. In the proposed approach, the use of the robotic master-slave system enables unique stimulation in which experimental participants can administer tactile cues on their own back using active self-touch. This active self-touch has never been employed in FBI experiments and it allows to test the role of sensorimotor integration and agency (the feeling of control over our actions) in FBI paradigms. The objective of this study is to propose a robotic-haptic platform allowing a new FBI paradigm including the active self-touch in MRI environments. This paper, first, describes the design concept and the performance of the prototype device in the fMRI environment (for 3T and 7T MRI scanners). In addition, the prototype device is applied to a classic FBI experiment, and we verify that the use of the prototype device succeeded in inducing the FBI. These results indicate that the proposed approach has a potential to drive advances in our understanding of human body ownership and agency by allowing novel manipulation and paradigms. Copyright © 2014 Elsevier B.V. All rights reserved.
Timing and tracking for the Crystal Barrel detector
NASA Astrophysics Data System (ADS)
Beck, Reinhard; Brinkmann, Kai; Novotny, Rainer
2017-01-01
The aim of the project D.3 is the upgrade of several detector components used in the CBELSA/TAPS experiment at ELSA. The readout of the Crystal Barrel Calorimeter will be extended by a timing branch in order to gain trigger capability for the detector, which will allow to measure completely neutral final states in photoproduction reactions (see projects A.1 and C.5). Additionally, the readout of the inner crystals of the TAPS detector, which covers the forward opening of the Crystal Barrel Calorimeter, will be modified to be capable of high event rates due to the intensity upgrade of ELSA. Furthermore, a full-scale prototype Time Projection Chamber (TPC) has been built to be used as a new central tracker for the CBELSA/TAPS experiment at ELSA and the FOPI experiment at GSI.
LANL OPERATING EXPERIENCE WITH THE WAND AND HERCULES PROTOTYPE SYSTEMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
K. M. GRUETZMACHER; C. L. FOXX; S. C. MYERS
2000-09-01
The Waste Assay for Nonradioactive Disposal (WAND) and the High Efficiency Radiation Counters for Ultimate Low Emission Sensitivity (HERCULES) prototype systems have been operating at Los Alamos National Laboratory's (LANL's) Solid Waste Operation's (SWO'S) non-destructive assay (NDA) building since 1997 and 1998, respectively. These systems are the cornerstone of the verification program for low-density Green is Clean (GIC) waste at the Laboratory. GIC waste includes all non-regulated waste generated in radiological controlled areas (RCAS) that has been actively segregated as clean (i.e., nonradioactive) through the use of waste generator acceptable knowledge (AK). The use of this methodology alters LANL's pastmore » practice of disposing of all room trash generated in nuclear facilities in radioactive waste landfills. Waste that is verified clean can be disposed of at the Los Alamos County Landfill. It is estimated that 50-90% of the low-density room trash from radioactive material handling areas at Los Alamos might be free of contamination. This approach avoids the high cost of disposal of clean waste at a radioactive waste landfill. It also reduces consumption of precious space in the radioactive waste landfill where disposal of this waste provides no benefit to the public or the environment. Preserving low level waste (LLW) disposal capacity for truly radioactive waste is critical in this era when expanding existing radioactive waste landfills or permitting new ones is resisted by regulators and stakeholders. This paper describes the operating experience with the WAND and HERCULES since they began operation at SWO. Waste for verification by the WAND system has been limited so far to waste from the Plutonium Facility and the Solid Waste Operations Facility. A total of461 ft3 (13.1 m3) of low-density shredded waste and paper have been verified clean by the WAND system. The HERCULES system has been used to verify waste from four Laboratory facilities. These are the Solid Waste Operations Facility, the TA-48 Chemistry Facility, the Shops Facility, and the Environmental Facility. A total of 3150 ft3 (89.3 m3) of low-density waste has been verified clean by the HERCULES system.« less
Evaluation of Prototype Automatic Truck Rollover Warning Systems
DOT National Transportation Integrated Search
1998-01-01
Three operating prototype Automatic Truck Rollover Warning Systems (ATRWS) installed on the Capital Beltway in Maryland and Virginia were evaluated for 3 years. The general objectives of this evaluation were to assess how the ATRWS performed and to d...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-26
... Munoz Rivera St., Aguas Buenas, 12000934 Florida Municipality De Luxe Florida, (Early Prototypes for... Corporation, (Early Prototypes for Manufacturing Plants in Puerto Rico, 1948-1958 MPS) PR 992, KM 0.3...
46 CFR 160.076-13 - Approval procedures for inflatable PFDs.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the application and, except as provided in paragraph (c)(2) of this section, a prototype PFD must be... been waived, the manufacturer is not required to send a prototype PFD sample to the Commandant. (3) The...
Home media server content management
NASA Astrophysics Data System (ADS)
Tokmakoff, Andrew A.; van Vliet, Harry
2001-07-01
With the advent of set-top boxes, the convergence of TV (broadcasting) and PC (Internet) is set to enter the home environment. Currently, a great deal of activity is occurring in developing standards (TV-Anytime Forum) and devices (TiVo) for local storage on Home Media Servers (HMS). These devices lie at the heart of convergence of the triad: communications/networks - content/media - computing/software. Besides massive storage capacity and being a communications 'gateway', the home media server is characterised by the ability to handle metadata and software that provides an easy to use on-screen interface and intelligent search/content handling facilities. In this paper, we describe a research prototype HMS that is being developed within the GigaCE project at the Telematica Instituut . Our prototype demonstrates advanced search and retrieval (video browsing), adaptive user profiling and an innovative 3D component of the Electronic Program Guide (EPG) which represents online presence. We discuss the use of MPEG-7 for representing metadata, the use of MPEG-21 working draft standards for content identification, description and rights expression, and the use of HMS peer-to-peer content distribution approaches. Finally, we outline explorative user behaviour experiments that aim to investigate the effectiveness of the prototype HMS during development.
Clinical data integration of distributed data sources using Health Level Seven (HL7) v3-RIM mapping
2011-01-01
Background Health information exchange and health information integration has become one of the top priorities for healthcare systems across institutions and hospitals. Most organizations and establishments implement health information exchange and integration in order to support meaningful information retrieval among their disparate healthcare systems. The challenges that prevent efficient health information integration for heterogeneous data sources are the lack of a common standard to support mapping across distributed data sources and the numerous and diverse healthcare domains. Health Level Seven (HL7) is a standards development organization which creates standards, but is itself not the standard. They create the Reference Information Model. RIM is developed by HL7's technical committees. It is a standardized abstract representation of HL7 data across all the domains of health care. In this article, we aim to present a design and a prototype implementation of HL7 v3-RIM mapping for information integration of distributed clinical data sources. The implementation enables the user to retrieve and search information that has been integrated using HL7 v3-RIM technology from disparate health care systems. Method and results We designed and developed a prototype implementation of HL7 v3-RIM mapping function to integrate distributed clinical data sources using R-MIM classes from HL7 v3-RIM as a global view along with a collaborative centralized web-based mapping tool to tackle the evolution of both global and local schemas. Our prototype was implemented and integrated with a Clinical Database management Systems CDMS as a plug-in module. We tested the prototype system with some use case scenarios for distributed clinical data sources across several legacy CDMS. The results have been effective in improving information delivery, completing tasks that would have been otherwise difficult to accomplish, and reducing the time required to finish tasks which are used in collaborative information retrieval and sharing with other systems. Conclusions We created a prototype implementation of HL7 v3-RIM mapping for information integration between distributed clinical data sources to promote collaborative healthcare and translational research. The prototype has effectively and efficiently ensured the accuracy of the information and knowledge extractions for systems that have been integrated PMID:22104558
Kutikov, Artem B.; Gurijala, Anvesh
2015-01-01
Two major factors hampering the broad use of rapid prototyped biomaterials for tissue engineering applications are the requirement for custom-designed or expensive research-grade three-dimensional (3D) printers and the limited selection of suitable thermoplastic biomaterials exhibiting physical characteristics desired for facile surgical handling and biological properties encouraging tissue integration. Properly designed thermoplastic biodegradable amphiphilic polymers can exhibit hydration-dependent hydrophilicity changes and stiffening behavior, which may be exploited to facilitate the surgical delivery/self-fixation of the scaffold within a physiological tissue environment. Compared to conventional hydrophobic polyesters, they also present significant advantages in blending with hydrophilic osteoconductive minerals with improved interfacial adhesion for bone tissue engineering applications. Here, we demonstrated the excellent blending of biodegradable, amphiphilic poly(D,L-lactic acid)-poly(ethylene glycol)-poly(D,L-lactic acid) (PLA-PEG-PLA) (PELA) triblock co-polymer with hydroxyapatite (HA) and the fabrication of high-quality rapid prototyped 3D macroporous composite scaffolds using an unmodified consumer-grade 3D printer. The rapid prototyped HA-PELA composite scaffolds and the PELA control (without HA) swelled (66% and 44% volume increases, respectively) and stiffened (1.38-fold and 4-fold increases in compressive modulus, respectively) in water. To test the hypothesis that the hydration-induced physical changes can translate into self-fixation properties of the scaffolds within a confined defect, a straightforward in vitro pull-out test was designed to quantify the peak force required to dislodge these scaffolds from a simulated cylindrical defect at dry versus wet states. Consistent with our hypothesis, the peak fixation force measured for the PELA and HA-PELA scaffolds increased 6-fold and 15-fold upon hydration, respectively. Furthermore, we showed that the low-fouling 3D PELA inhibited the attachment of NIH3T3 fibroblasts or bone marrow stromal cells while the HA-PELA readily supported cellular attachment and osteogenic differentiation. Finally, we demonstrated the feasibility of rapid prototyping biphasic PELA/HA-PELA scaffolds for potential guided bone regeneration where an osteoconductive scaffold interior encouraging osteointegration and a nonadhesive surface discouraging fibrous tissue encapsulation is desired. This work demonstrated that by combining facile and readily translatable rapid prototyping approaches with unique biomaterial designs, biodegradable composite scaffolds with well-controlled macroporosities, spatially defined biological microenvironment, and useful handling characteristics can be developed. PMID:25025950
Mesoscale fabrication and design
NASA Astrophysics Data System (ADS)
Hayes, Gregory R.
A strong link between mechanical engineering design and materials science and engineering fabrication can facilitate an effective and adaptable prototyping process. In this dissertation, new developments in the lost mold-rapid infiltration forming (LM-RIF) process is presented which demonstrates the relationship between these two fields of engineering in the context of two device applications. Within the LM-RIF process, changes in materials processing and mechanical design are updated iteratively, often aided by statistical design of experiments (DOE). The LM-RIF process was originally developed by Antolino and Hayes et al to fabricate mesoscale components. In this dissertation the focus is on advancements in the process and underlying science. The presented advancements to the LM-RIF process include an augmented lithography procedure, the incorporation of engineered aqueous and non-aqueous colloidal suspensions, an assessment of constrained drying forces during LM-RIF processing, mechanical property evaluation, and finally prototype testing and validation. Specifically, the molding procedure within the LM-RIF process is capable of producing molds with thickness upwards of 1mm, as well as multi-layering to create three dimensional structures. Increasing the mold thickness leads to an increase in the smallest feature resolvable; however, the increase in mold thickness and three dimensional capability has expanded the mechanical design space. Tetragonally stabilized zirconia (3Y-TZP) is an ideal material for mesoscale instruments, as it is biocompatible, exhibits high strength, and is chemically stable. In this work, aqueous colloidal suspensions were formulated with two new gel-binder systems, increasing final natural orifice translumenal endoscopic surgery (NOTES) instrument yield from 0% to upwards of 40% in the best case scenario. The effects of the gel-binder system on the rheological behavior of the suspension along with the thermal characteristics of the gel-binder system were characterized. Finally, mechanical properties of ceramic specimens were obtained via 3-point bend testing. Another candidate material for NOTES devices as well as cellular contact aided compliant mechanisms (C3M) devices is 300 series stainless steel (300 series stainless steel). 300 series stainless steel is a common biocompatible material; it is used in surgical applications, exhibits a high corrosion resistance, and has high strength to failure. New, high solids loading, non-aqueous colloidal suspensions of 300 series stainless steel were formulated and incorporated into the LM-RIF process. The rheological behavior and thermal characteristics of the non-aqueous colloidal suspensions were analyzed and engineered to operate within the LM-RIF process. Final part yield with the non-aqueous colloidal suspensions was higher than that of the aqueous ceramic suspensions. Mechanical properties of 300 series stainless steel specimens were determined via 3-point bend testing. Furthermore, new composite non-aqueous colloidal suspensions of 3Y-TZP and 300 series stainless steel were formulated and incorporated into the LM-RIF process. The composite materials showed an increase in final part yield, and an increase in yield strength compared to pure 300 series stainless steel was determined by Vickers hardness testing. The successful incorporation of composite suspensions in the LM-RIF process was facilitated through an analysis of the rheological behavior as a function of solids loading and ceramic to metal ratio. Optimized designs of NOTES instruments, as well as C3M devices were manufactured using the LM-RIF process with the non-aqueous 300 series stainless steel suspension. The performance of the prototype NOTES instruments was evaluated and compared against the theoretically predicted performance results, showing good agreement. Similarly, good agreement was seen between the stress-displacement behavior of prototype C3M devices when compared to the theoretically calculated stress-displacement results. Finally, in a comparison by endoscopic surgeons at Hershey Medical Center between an existing industry standard endoscopic device and the mesoscale instrument prototypes fabricated via the LM-RIF process, the prototype design performed favorably in almost all categories. (Abstract shortened by UMI.)
Taher, Fadi; Falkensammer, Juergen; McCarte, Jamie; Strassegger, Johann; Uhlmann, Miriam; Schuch, Philipp; Assadian, Afshin
2017-06-01
The fenestrated Anaconda endograft (Vascutek/Terumo, Inchinnan, UK) is intended for the treatment of abdominal aortic aneurysms with an insufficient infrarenal landing zone. The endografts are custom-made with use of high-resolution, 1-mm-slice computed tomography angiography images. For every case, a nonsterile prototype and a three-dimensional (3D) model of the patient's aorta are constructed to allow the engineers as well as the physician to test-implant the device and to review the fit of the graft. The aim of this investigation was to assess the impact of 3D model construction and prototype testing on the design of the final sterile endograft. A prospectively held database on fenestrated endovascular aortic repair patients treated at a single institution was completed with data from the Vascutek engineers' prototype test results as well as the product request forms. Changes to endograft design based on prototype testing were assessed and are reported for all procedures. Between April 1, 2013, and August 18, 2015, 60 fenestrated Anaconda devices were implanted. Through prototype testing, engineers were able to identify and report potential risks to technical success related to use of the custom device for the respective patient. Theoretical concerns about endograft fit in the rigid model were expressed in 51 cases (85.0%), and the engineers suggested potential changes to the design of 21 grafts (35.0%). Thirteen cases (21.7%) were eventually modified after the surgeon's testing of the prototype. A second prototype was ordered in three cases (5.0%) because of extensive changes to endograft design, such as inclusion of an additional fenestration. Technical success rates were comparable for grafts that showed a perfect fit from the beginning and cases in which prototype testing resulted in a modification of graft design. Planning and construction of fenestrated endografts for complex aortic anatomies where exact fit and positioning of the graft are paramount to allow cannulation of the aortic branches are challenging. In the current series, approximately one in five endografts was modified after prototype testing in an aortic model. Eventually, success rates were comparable between the groups of patients with a good primary prototype fit and those in which the endograft design was altered. Prototype testing in 3D aortic models is a valuable tool to test the fit of a custom-made endograft before implantation. This may help avoid potentially debilitating adverse events associated with misaligned fenestrations and unconnected aortic branches. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Billam, P; LeRoith, T; Pudupakam, R S; Pierson, F W; Duncan, R B; Meng, X J
2009-11-18
Avian hepatitis E virus (avian HEV) is the primary causative agent of Hepatitis-Splenomegaly (HS) syndrome in chickens. Recently, a genetically unique strain of avian HEV, designated avian HEV-VA, was recovered from healthy chickens in Virginia. The objective of this study was to experimentally compare the pathogenicity of the prototype strain recovered from a chicken with HS syndrome and the avian HEV-VA strain in specific-pathogen-free chickens. An infectious stock of the avian HEV-VA strain was first generated and its infectivity titer determined in chickens. For the comparative pathogenesis study, 54 chickens of 6-week-old were assigned to 3 groups of 18 chickens each. The group 1 chickens were each intravenously inoculated with 5x10(2.5) 50% chicken infectious dose of the prototype strain. The group 2 received the same dose of the avian HEV-VA strain, and the group 3 served as negative controls. Six chickens from each group were necropsied at 2, 3 and 4 weeks post-inoculation (wpi). Most chickens in both inoculated groups seroconverted by 3wpi, and the mean anti-avian HEV antibody titers were higher for the prototype strain group than the avian HEV-VA strain group. There was no significant difference in the patterns of viremia and fecal virus shedding. Blood analyte profiles did not differ between treatment groups except for serum creatine phosphokinase levels which were higher for prototype avian HEV group than avian HEV-VA group. The hepatic lesion score was higher for the prototype strain group than the other two groups. The results indicated that the avian HEV-VA strain is only slightly attenuated compared to the prototype strain, suggesting that the full spectrum of HS syndrome is likely associated with other co-factors.
History-Enriched Spaces for Shared Encounters
NASA Astrophysics Data System (ADS)
Konomi, Shin'ichi; Sezaki, Kaoru; Kitsuregawa, Masaru
We discuss "history-enriched spaces" that use historical data to support shared encounters. We first examine our experiences with DeaiExplorer, a social network display that uses RFID and a historical database to support social interactions at academic conferences. This leads to our discussions on three complementary approaches to addressing the issues of supporting social encounters: (1) embedding historical data in embodied interactions, (2) designing for weakly involved interactions such as social navigation, and (3) designing for privacy. Finally, we briefly describe a preliminary prototype of a proxemics-based awareness tool that considers these approaches.
Advances in three-dimensional rapid prototyping of microfluidic devices for biological applications
O'Neill, P. F.; Ben Azouz, A.; Vázquez, M.; Liu, J.; Marczak, S.; Slouka, Z.; Chang, H. C.; Diamond, D.; Brabazon, D.
2014-01-01
The capability of 3D printing technologies for direct production of complex 3D structures in a single step has recently attracted an ever increasing interest within the field of microfluidics. Recently, ultrafast lasers have also allowed developing new methods for production of internal microfluidic channels within the bulk of glass and polymer materials by direct internal 3D laser writing. This review critically summarizes the latest advances in the production of microfluidic 3D structures by using 3D printing technologies and direct internal 3D laser writing fabrication methods. Current applications of these rapid prototyped microfluidic platforms in biology will be also discussed. These include imaging of cells and living organisms, electrochemical detection of viruses and neurotransmitters, and studies in drug transport and induced-release of adenosine triphosphate from erythrocytes. PMID:25538804
Lee, Shu Jin; Lee, Heow Pueh; Tse, Kwong Ming; Cheong, Ee Cherk; Lim, Siak Piang
2012-06-01
Complex 3-D defects of the facial skeleton are difficult to reconstruct with freehand carving of autogenous bone grafts. Onlay bone grafts are hard to carve and are associated with imprecise graft-bone interface contact and bony resorption. Autologous cartilage is well established in ear reconstruction as it is easy to carve and is associated with minimal resorption. In the present study, we aimed to reconstruct the hypoplastic orbitozygomatic region in a patient with left hemifacial microsomia using computer-aided design and rapid prototyping to facilitate costal cartilage carving and grafting. A three-step process of (1) 3-D reconstruction of the computed tomographic image, (2) mirroring the facial skeleton, and (3) modeling and rapid prototyping of the left orbitozygomaticomalar region and reconstruction template was performed. The template aided in donor site selection and extracorporeal contouring of the rib cartilage graft to allow for an accurate fit of the graft to the bony model prior to final fixation in the patient. We are able to refine the existing computer-aided design and rapid prototyping methods to allow for extracorporeal contouring of grafts and present rib cartilage as a good alternative to bone for autologous reconstruction.
High performance 1.2 Ah Si-alloy/Graphite|LiNi0.5Mn0.3Co0.2O2 prototype Li-ion battery
NASA Astrophysics Data System (ADS)
Marinaro, Mario; Yoon, Dong-hwan; Gabrielli, Giulio; Stegmaier, Petra; Figgemeier, Egbert; Spurk, Paul C.; Nelis, Daniël; Schmidt, Gregory; Chauveau, Jerome; Axmann, Peter; Wohlfahrt-Mehrens, Margret
2017-07-01
The study reports on realization and electrochemical testing of prototype Si-alloy/Graphite|LiNi0.5Mn0.3Co0.2O2 batteries. Water soluble polyacrylic acid (PAA), used as the only binder at the anode side, demonstrates excellent dispersant and binding properties. Sedimentation tests and rheological measurements show remarkable stability and mostly a thinning behavior of the non-Newtonian type of slurry. The cathode is processed in N-Methylpyrrolidone based slurry using polyvinylidene fluoride (PVDF) as the binding agent. The electronic conductivities of the manufactured Si-alloy/Graphite and LiNi0.5Mn0.3Co0.2O2 electrodes are evaluated. Furthermore, the cathode and anode electrochemical behavior is initially studied in half-cells, and subsequently in full Li-ion stacked prototype soft pouch-cells (1.22 Ah). It is demonstrated that the manufactured prototype cells can sustain about 290 charge/discharge galvanostatic cycles before the retained capacity drops below 80%. Cell aging is monitored using Electrochemical Impedance Spectroscopy (EIS), whereas post-mortem SEM analysis of electrodes cross-section is used to shed light on the causes of performance degradation of the cells.
Three-dimensional (3D) printing and its applications for aortic diseases
Hangge, Patrick; Pershad, Yash; Witting, Avery A.; Albadawi, Hassan
2018-01-01
Three-dimensional (3D) printing is a process which generates prototypes from virtual objects in computer-aided design (CAD) software. Since 3D printing enables the creation of customized objects, it is a rapidly expanding field in an age of personalized medicine. We discuss the use of 3D printing in surgical planning, training, and creation of devices for the treatment of aortic diseases. 3D printing can provide operators with a hands-on model to interact with complex anatomy, enable prototyping of devices for implantation based upon anatomy, or even provide pre-procedural simulation. Potential exists to expand upon current uses of 3D printing to create personalized implantable devices such as grafts. Future studies should aim to demonstrate the impact of 3D printing on outcomes to make this technology more accessible to patients with complex aortic diseases. PMID:29850416
Very High Load Capacity Air Bearing Spindle for Large Diamond Turning Machines
2010-06-08
testing and a surplus air bearing rotary table has been located. A prototype spindle has been designed to work with the table. 15. SUBJECT TERMS...MSFC) • PROTOTYPE SPINDLE DESIGN June 8, 2010Mirror Technology Workshop 3 Introduction • DT is a proven method of manufacturing aspheric off-axis... designed to hold in a strain-free condition. This spindle development is aimed at producing 3 meter diameter components. This requirement results in the
Shellock, Frank G; Valencerina, Samuel
2008-01-01
Purpose To evaluate MRI issues at 3-Tesla for a ventricular assist device (VAD). Methods The AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached (Abiomed, Inc., Danvers, MA) was evaluated for magnetic field interactions, heating, and artifacts at 3-Tesla. MRI-related heating was assessed with the device in a gelled-saline-filled, head/torso phantom using a transmit/received RF body coil while performing MRI at a whole body averaged SAR of 3-W/kg for 15-min. Artifacts were assessed for the main metallic component of this VAD (atrial cannula) using T1-weighted, spin echo and gradient echo pulse sequences. Results The AB5000 Ventricle with the prototype In-Flow Cannula and Out-Flow Cannula attached showed relatively minor magnetic field interactions that will not cause movement in situ. Heating was not excessive (highest temperature change, +0.8°C). Artifacts may create issues for diagnostic imaging if the area of interest is in the same area or close to the implanted metallic component of this VAD (i.e., the venous cannula). Conclusion The results of this investigation demonstrated that it would be acceptable for a patient with this VAD (AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached) to undergo MRI at 3-Tesla or less. Notably, it is likely that the operation console for this device requires positioning a suitable distance (beyond the 100 Gauss line or in the MR control room) from the 3-Tesla MR system to ensure proper function of the VAD. PMID:18495028
41. ARAIII Prototype assembly and evaluation building ARA630. West end ...
41. ARA-III Prototype assembly and evaluation building ARA-630. West end and south side of building. Camera facing northeast. Ineel photo no. 3-22. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
Rapid Prototyping Enters Mainstream Manufacturing.
ERIC Educational Resources Information Center
Winek, Gary
1996-01-01
Explains rapid prototyping, a process that uses computer-assisted design files to create a three-dimensional object automatically, speeding the industrial design process. Five commercially available systems and two emerging types--the 3-D printing process and repetitive masking and depositing--are described. (SK)
Investigating the role of implicit prototypes in the prototype willingness model.
Howell, Jennifer L; Ratliff, Kate A
2017-06-01
One useful theory to predict health behavior is the prototype-willingness model (PWM), which posits that people are more willing to engage in behavior to the extent that they have a positive view of the prototypical person who performs that behavior. The goal of the present research is to test whether adding an implicit measure of prototype favorability might improve explanatory power in the PWM. Two studies examined whether implicit prototype favorability uniquely predicted White women's intentions to engage in healthy sun behavior over the next 3-6 months, and their willingness to engage in risky sun behavior, should the opportunity arise. The results suggested that implicit prototype favorability, particularly implicit prototypes of those who engage in risky UV-related behaviors, uniquely predicted intentions to engage in healthy sun behavior and willingness to engage in risky sun behavior in the PWM.
Probabilistic Climate Scenario Information for Risk Assessment
NASA Astrophysics Data System (ADS)
Dairaku, K.; Ueno, G.; Takayabu, I.
2014-12-01
Climate information and services for Impacts, Adaptation and Vulnerability (IAV) Assessments are of great concern. In order to develop probabilistic regional climate information that represents the uncertainty in climate scenario experiments in Japan, we compared the physics ensemble experiments using the 60km global atmospheric model of the Meteorological Research Institute (MRI-AGCM) with multi-model ensemble experiments with global atmospheric-ocean coupled models (CMIP3) of SRES A1b scenario experiments. The MRI-AGCM shows relatively good skills particularly in tropics for temperature and geopotential height. Variability in surface air temperature of physical ensemble experiments with MRI-AGCM was within the range of one standard deviation of the CMIP3 model in the Asia region. On the other hand, the variability of precipitation was relatively well represented compared with the variation of the CMIP3 models. Models which show the similar reproducibility in the present climate shows different future climate change. We couldn't find clear relationships between present climate and future climate change in temperature and precipitation. We develop a new method to produce probabilistic information of climate change scenarios by weighting model ensemble experiments based on a regression model (Krishnamurti et al., Science, 1999). The method can be easily applicable to other regions and other physical quantities, and also to downscale to finer-scale dependent on availability of observation dataset. The prototype of probabilistic information in Japan represents the quantified structural uncertainties of multi-model ensemble experiments of climate change scenarios. Acknowledgments: This study was supported by the SOUSEI Program, funded by Ministry of Education, Culture, Sports, Science and Technology, Government of Japan.
Assessment of a human computer interface prototyping environment
NASA Technical Reports Server (NTRS)
Moore, Loretta A.
1993-01-01
A Human Computer Interface (HCI) prototyping environment with embedded evaluation capability has been successfully assessed which will be valuable in developing and refining HCI standards and evaluating program/project interface development, especially Space Station Freedom on-board displays for payload operations. The HCI prototyping environment is designed to include four components: (1) a HCI format development tool, (2) a test and evaluation simulator development tool, (3) a dynamic, interactive interface between the HCI prototype and simulator, and (4) an embedded evaluation capability to evaluate the adequacy of an HCI based on a user's performance.
US NDC Modernization Iteration E2 Prototyping Report: User Interface Framework
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, Jennifer E.; Palmer, Melanie A.; Vickers, James Wallace
2014-12-01
During the second iteration of the US NDC Modernization Elaboration phase (E2), the SNL US NDC Modernization project team completed follow-on Rich Client Platform (RCP) exploratory prototyping related to the User Interface Framework (UIF). The team also developed a survey of browser-based User Interface solutions and completed exploratory prototyping for selected solutions. This report presents the results of the browser-based UI survey, summarizes the E2 browser-based UI and RCP prototyping work, and outlines a path forward for the third iteration of the Elaboration phase (E3).
Integration of 3D printing and additive manufacturing in the interventional pulmonologist's toolbox.
Guibert, Nicolas; Mhanna, Laurent; Didier, Alain; Moreno, Benjamin; Leyx, Pierre; Plat, Gavin; Mazieres, Julien; Hermant, Christophe
2018-01-01
New 3D technologies are rapidly entering into the surgical landscape, including in interventional pulmonology. The transition of 2D restricted data into a physical model of pathological airways by three-dimensional printing (3DP) allows rapid prototyping and fabrication of complex and patient-specific shapes and can thus help the physician to plan and guide complex procedures. Furthermore, computer-assisted designed (CAD) patient-specific devices have already helped surgeons overcome several therapeutic impasses and are likely to rapidly cover a wider range of situations. We report herein with a special focus on our clinical experience: i) how additive manufacturing is progressively integrated into the management of complex central airways diseases; ii) the appealing future directions of these new technologies, including the potential of the emerging technique of bioprinting; iii) the main pitfalls that could delay its introduction into routine care. Copyright © 2017. Published by Elsevier Ltd.
Ion beam modification of topological insulator bismuth selenide
Sharma, Peter Anand; Sharma, A. L. Lima; Hekmaty, Michelle A.; ...
2014-12-17
In this study, we demonstrate chemical doping of a topological insulator Bi 2Se 3 using ion implantation. Ion beam-induced structural damage was characterized using grazing incidence X-ray diffraction and transmission electron microscopy. Ion damage was reversed using a simple thermal annealing step. Carrier-type conversion was achieved using ion implantation followed by an activation anneal in Bi 2Se 3 thin films. These two sets of experiments establish the feasibility of ion implantation for chemical modification of Bi 2Se 3, a prototypical topological insulator. Ion implantation can, in principle, be used for any topological insulator. The direct implantation of dopants should allowmore » better control over carrier concentrations for the purposes of achieving low bulk conductivity. Ion implantation also enables the fabrication of inhomogeneously doped structures, which in turn should make possible new types of device designs.« less
INHIBITION OF MYCOLIC ACID TRANSPORT ACROSS THE MYCOBACTERIUM TUBERCULOSIS PLASMA MEMBRANE
Grzegorzewicz, Anna E.; Pham, Ha; Gundi, Vijay A. K. B.; Scherman, Michael S.; North, Elton J.; Hess, Tamara; Jones, Victoria; Gruppo, Veronica; Born, Sarah E. M.; Korduláková, Jana; Chavadi, Sivagami Sundaram; Morisseau, Christophe; Lenaerts, Anne J.; Lee, Richard E.; McNeil, Michael R.; Jackson, Mary
2011-01-01
New chemotherapeutics active against multidrug-resistant Mycobacterium tuberculosis (M. tb) are urgently needed. We report on the identification of an adamantyl urea compound displaying potent bactericidal activity against M. tb and a unique mode of action, namely the abolition of the translocation of mycolic acids from the cytoplasm where they are synthesized to the periplasmic side of the plasma membrane where they are transferred onto cell wall arabinogalactan or used in the formation of virulence-associated outer membrane trehalose-containing glycolipids. Whole genome sequencing of spontaneous resistant mutants of M. tb selected in vitro followed by genetic validation experiments revealed that our prototype inhibitor targets the inner membrane transporter, MmpL3. Conditional gene expression of mmpL3 in mycobacteria and analysis of inhibitor-treated cells validate MmpL3 as essential for mycobacterial growth and support the involvement of this transporter in the translocation of trehalose monomycolate across the plasma membrane. PMID:22344175
Endodontic applications of 3D printing.
Anderson, J; Wealleans, J; Ray, J
2018-02-27
Computer-aided design (CAD) and computer-aided manufacturing (CAM) technologies can leverage cone beam computed tomography data for production of objects used in surgical and nonsurgical endodontics and in educational settings. The aim of this article was to review all current applications of 3D printing in endodontics and to speculate upon future directions for research and clinical use within the specialty. A literature search of PubMed, Ovid and Scopus was conducted using the following terms: stereolithography, 3D printing, computer aided rapid prototyping, surgical guide, guided endodontic surgery, guided endodontic access, additive manufacturing, rapid prototyping, autotransplantation rapid prototyping, CAD, CAM. Inclusion criteria were articles in the English language documenting endodontic applications of 3D printing. Fifty-one articles met inclusion criteria and were utilized. The endodontic literature on 3D printing is generally limited to case reports and pre-clinical studies. Documented solutions to endodontic challenges include: guided access with pulp canal obliteration, applications in autotransplantation, pre-surgical planning and educational modelling and accurate location of osteotomy perforation sites. Acquisition of technical expertise and equipment within endodontic practices present formidable obstacles to widespread deployment within the endodontic specialty. As knowledge advances, endodontic postgraduate programmes should consider implementing 3D printing into their curriculums. Future research directions should include clinical outcomes assessments of treatments employing 3D printed objects. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Laparoscopic prototype for optical sealing of renal blood vessels
NASA Astrophysics Data System (ADS)
Hardy, Luke A.; Hutchens, Thomas C.; Larson, Eric R.; Gonzalez, David A.; Chang, Chun-Hung; Nau, William H.; Fried, Nathaniel M.
2017-02-01
Energy-based, radiofrequency and ultrasonic devices provide rapid sealing of blood vessels during laparoscopic procedures. We are exploring infrared lasers as an alternative for vessel sealing with less collateral thermal damage. Previous studies demonstrated vessel sealing in an in vivo porcine model using a 1470-nm laser. However, the initial prototype was designed for open surgery and featured tissue clasping and light delivery mechanisms incompatible with laparoscopic surgery. In this study, a laparoscopic prototype similar to devices in surgical use was developed, and tests were conducted on porcine renal blood vessels. The 5-mm-OD prototype featured a traditional Maryland jaw configuration. Laser energy was delivered through a 550-μm-core fiber and side-delivery from the lower jaw, with beam dimensions of 18-mm-length x 1.2-mm-width. The 1470-nm diode laser delivered 68 W with 3 s activation time. A total of 69 porcine renal vessels with mean diameter of 3.3 +/- 1.7 mm were tested, ex vivo. Vessels smaller than 5 mm were consistently sealed (48/51) with burst pressures greater than malignant hypertension blood pressure (180 mmHg), averaging 1038 +/- 474 mmHg. Vessels larger than 5 mm were not consistently sealed (6/18), yielding burst pressures of only 174 +/- 221 mmHg. Seal width, thermal damage zone, and thermal spread averaged 1.7 +/- 0.8, 3.4 +/- 0.7, and 1.0 +/- 0.4 mm. A novel optical laparoscopic prototype with 5-mm- OD shaft integrated within a standard Maryland jaw design consistently sealed vessels less than 5 mm with minimal thermal spread. Further in vivo studies are planned to test performance across a variety of vessels and tissues.
Prototype Solid State Induction Modulator for SLAC NLC
NASA Astrophysics Data System (ADS)
Cassel, R. L.; DeLamare, J. E.; Nguyen, M. N.; Pappas, G. C.; Cook, E.
2002-08-01
The Next Linear Collider accelerator proposal at SLAC requires a high efficiency, highly reliable, and low cost pulsed power modulator to drive the X band klystrons. The present NLC envisions a solid-state induction modulator design to drive up to 8 klystrons to 500kV for 3muS at 120 PPS with one modulator (>1,000 megawatt pulse, 500kW average). A prototype modulator is presently under construction, which well power 4 each 5045 SLAC klystron to greater than 380 kV for 3muS (>600 megawatt pulse, >300 kW Ave.). The modulator will be capable of driving the 8 each X band klystrons when they become available. The paper covers the design, construction, fabrication and preliminary testing of the prototype modulator.
Building a generalized distributed system model
NASA Technical Reports Server (NTRS)
Mukkamala, R.
1992-01-01
The key elements in the second year (1991-92) of our project are: (1) implementation of the distributed system prototype; (2) successful passing of the candidacy examination and a PhD proposal acceptance by the funded student; (3) design of storage efficient schemes for replicated distributed systems; and (4) modeling of gracefully degrading reliable computing systems. In the third year of the project (1992-93), we propose to: (1) complete the testing of the prototype; (2) enhance the functionality of the modules by enabling the experimentation with more complex protocols; (3) use the prototype to verify the theoretically predicted performance of locking protocols, etc.; and (4) work on issues related to real-time distributed systems. This should result in efficient protocols for these systems.
Performance of timing Resistive Plate Chambers with protons from 200 to 800 MeV
NASA Astrophysics Data System (ADS)
Machado, J.; Adamczewski-Musch, J.; Blanco, A.; Boretzky, K.; Cabanelas, P.; Cartegni, L.; Ferreira Marques, R.; Fonte, P.; Fruehauf, J.; Galaviz, D.; Heil, M.; Henriques, A.; . Ickert, G.; Körper, D.; Lopes, L.; Palka, M.; Pereira, A.; Rossi, D.; Simon, H.; Teubig, P.; Traxler, M.; Velho, P.; Altstadt, S.; Atar, L.; Aumann, T.; Bemmerer, D.; Caesar, C.; Charpy, A.; Elekes, Z.; Fiori, E.; Gasparic, I.; Gerbig, J.; Göbel, K.; Heftrich, T.; Heine, M.; Heinz, A.; Holl, M.; Ignatov, A.; Isaak, J.; Johansson, H.; Kelic-Heil, A.; Lederer, C.; Lindberg, S.; Löher, B.; Marganiec, J.; Martensson, M.; Nilsson, T.; Panin, V.; Paschalis, S.; Petri, M.; Plag, R.; Pohl, M.; Rastrepina, G.; Reifarth, R.; Reinhardt, T. P.; Röder, M.; Savran, D.; Scheit, H.; Schrock, P.; Silva, J.; Stach, D.; Strannerdahl, F.; Thies, R.; Wagner, A.; Wamers, F.; Weigand, M.
2015-01-01
A prototype composed of four resistive plate chamber layers has been exposed to quasi-monoenergetic protons produced from a deuteron beam of varying energy (200 to 800 AMeV) in experiment S406 at GSI, Darmstadt, Germany. The aim of the experiment is to characterize the response of the prototype to protons in this energy range, which deposit from 1.75 to 6 times more energy than minimum ionizing particles. Each layer, with an active area of about 2000 × 500 mm2, is made of modules containing the active gaps, all in multigap construction. Each gap is defined by 0.3 mm nylon mono-filaments positioned between 2.85 mm thick float glass electrodes. The modules are operated in avalanche mode with a non-flammable gas mixture composed of 90% C2H2F4 and 10% SF6. The signals are readout by a pick-up electrode formed by 15 copper strips (per layer), spaced at a pitch of 30 mm, connected at both sides to timing front end electronics. Results show an uniform efficiency close to 100% along with a timing resolution of around 60 ps on the entire 2000 × 500 mm2 area.
A multiple camera tongue switch for a child with severe spastic quadriplegic cerebral palsy.
Leung, Brian; Chau, Tom
2010-01-01
The present study proposed a video-based access technology that facilitated a non-contact tongue protrusion access modality for a 7-year-old boy with severe spastic quadriplegic cerebral palsy (GMFCS level 5). The proposed system featured a centre camera and two peripheral cameras to extend coverage of the frontal face view of this user for longer durations. The child participated in a descriptive case study. The participant underwent 3 months of tongue protrusion training while the multiple camera tongue switch prototype was being prepared. Later, the participant was brought back for five experiment sessions where he worked on a single-switch picture matching activity, using the multiple camera tongue switch prototype in a controlled environment. The multiple camera tongue switch achieved an average sensitivity of 82% and specificity of 80%. In three of the experiment sessions, the peripheral cameras were associated with most of the true positive switch activations. These activations would have been missed by a centre-camera-only setup. The study demonstrated proof-of-concept of a non-contact tongue access modality implemented by a video-based system involving three cameras and colour video processing.
Summary of the National Toxicology Program benzidine dye initiative.
Morgan, D L; Dunnick, J K; Goehl, T; Jokinen, M P; Matthews, H B; Zeiger, E; Mennear, J H
1994-01-01
The benzidine dye initiative is a research program established by the National Toxicology Program to generate an integrated body of scientific information regarding the potential health risks associated with exposure to benzidine- and benzidine-congener-derived dyes. Because an in-depth evaluation of each of the hundreds of benzidine-congener-derived dyes was considered impractical, the research program was designed to study the metabolism and disposition, genetic toxicity, and in vivo toxicity and carcinogenicity of two primary benzidine congeners, 3,3'-dimethylbenzidine and 3,3'-dimethoxybenzidine, and a select group of prototypical dyes derived from those amines. It was anticipated that by applying the basic information generated in these extensive studies, it would be possible to make regulatory decisions about other dyes after conducting only a minimal number of experiments such as studies of disposition and metabolism, and in vitro mutagenicity. This paper summarizes the results of studies conducted to evaluate the metabolism, disposition, mutagenicity, toxicity, and carcinogenicity of representative benzidine congeners and derived dyes. PMID:7925189
Prototype solar heating and cooling systems
NASA Technical Reports Server (NTRS)
1978-01-01
A collection of monthly status reports on the development of eight prototype solar heating and cooling systems is presented. The effort calls for the development, manufacture, test, system installation, maintenance, problem resolution, and performance evaluation. The systems are 3, 25, and 75 ton size units.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durfee, Justin David; Frazier, Christopher Rawls; Bandlow, Alisa
2016-05-01
The Contingency Contractor Optimization Tool - Prototype (CCOT-P) requires several third-party software packages. These are documented below for each of the CCOT-P elements: client, web server, database server, solver, web application and polling application.
Prototype solar heating and cooling systems
NASA Technical Reports Server (NTRS)
1978-01-01
A collection of monthly status reports are given on the development of eight prototype solar heating and cooling systems. This effort calls for the development, manufacturing, test, system installation, maintenance, problem resolution, and performance evaluation. The systems are 3-, 25-, and 75-ton size units.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kroll, Florian; Karsch, Leonhard; Pawelke, Jörg
2013-08-15
Purpose: Clinical QA in teletherapy as well as the characterization of experimental radiation sources for future medical applications requires effective methods for measuring three-dimensional (3D) dose distributions generated in a water-equivalent medium. Current dosimeters based on ionization chambers, diodes, thermoluminescence detectors, radiochromic films, or polymer gels exhibit various drawbacks: High quality 3D dose determination is either very sophisticated and expensive or requires high amounts of effort and time for the preparation or read out. New detectors based on scintillator blocks in combination with optical tomography are studied, since they have the potential to facilitate the desired cost-effective, transportable, and long-termmore » stable dosimetry system that is able to determine 3D dose distributions with high spatial resolution in a short time.Methods: A portable detector prototype was set up based on a plastic scintillator block and four digital cameras. During irradiation the scintillator emits light, which is detected by the fixed cameras. The light distribution is then reconstructed by optical tomography, using maximum-likelihood expectation maximization. The result of the reconstruction approximates the 3D dose distribution. First performance tests of the prototype using laser light were carried out. Irradiation experiments were performed with ionizing radiation, i.e., bremsstrahlung (6 to 21 MV), electrons (6 to 21 MeV), and protons (68 MeV), provided by clinical and research accelerators.Results: Laser experiments show that the current imaging properties differ from the design specifications: The imaging scale of the optical systems is position dependent, ranging from 0.185 mm/pixel to 0.225 mm/pixel. Nevertheless, the developed dosimetry method is proven to be functional for electron and proton beams. Induced radiation doses of 50 mGy or more made 3D dose reconstructions possible. Taking the imaging properties into account, determined dose profiles are in agreement with reference measurements. An inherent drawback of the scintillator is the nonlinear light output for high stopping-power radiation due to the quenching effect. It impacts the depth dose curves measured with the dosimeter. For single Bragg peak distributions this leads to a peak to plateau ratio of 2.8 instead of 4.5 for the reference ionization chamber measurement. Furthermore, the transmission of the clinical bremsstrahlung beams through the scintillator leads to the saturation of one camera, making dose reconstructions in that case presently not feasible.Conclusions: It is shown that distributions of scintillation light generated by proton or electron beams can be reconstructed by the dosimetry system within minutes. The quenching apparent for proton irradiation, and the yet not precisely determined position dependency of the imaging scale, require further investigation and corrections. Upgrading the prototype with larger or inorganic scintillators would increase the detectable proton and electron energy range. The presented results show that the determination of 3D dose distributions using scintillator blocks and optical tomography is a promising dosimetry method.« less
Kroll, Florian; Pawelke, Jörg; Karsch, Leonhard
2013-08-01
Clinical QA in teletherapy as well as the characterization of experimental radiation sources for future medical applications requires effective methods for measuring three-dimensional (3D) dose distributions generated in a water-equivalent medium. Current dosimeters based on ionization chambers, diodes, thermoluminescence detectors, radiochromic films, or polymer gels exhibit various drawbacks: High quality 3D dose determination is either very sophisticated and expensive or requires high amounts of effort and time for the preparation or read out. New detectors based on scintillator blocks in combination with optical tomography are studied, since they have the potential to facilitate the desired cost-effective, transportable, and long-term stable dosimetry system that is able to determine 3D dose distributions with high spatial resolution in a short time. A portable detector prototype was set up based on a plastic scintillator block and four digital cameras. During irradiation the scintillator emits light, which is detected by the fixed cameras. The light distribution is then reconstructed by optical tomography, using maximum-likelihood expectation maximization. The result of the reconstruction approximates the 3D dose distribution. First performance tests of the prototype using laser light were carried out. Irradiation experiments were performed with ionizing radiation, i.e., bremsstrahlung (6 to 21 MV), electrons (6 to 21 MeV), and protons (68 MeV), provided by clinical and research accelerators. Laser experiments show that the current imaging properties differ from the design specifications: The imaging scale of the optical systems is position dependent, ranging from 0.185 mm/pixel to 0.225 mm/pixel. Nevertheless, the developed dosimetry method is proven to be functional for electron and proton beams. Induced radiation doses of 50 mGy or more made 3D dose reconstructions possible. Taking the imaging properties into account, determined dose profiles are in agreement with reference measurements. An inherent drawback of the scintillator is the nonlinear light output for high stopping-power radiation due to the quenching effect. It impacts the depth dose curves measured with the dosimeter. For single Bragg peak distributions this leads to a peak to plateau ratio of 2.8 instead of 4.5 for the reference ionization chamber measurement. Furthermore, the transmission of the clinical bremsstrahlung beams through the scintillator leads to the saturation of one camera, making dose reconstructions in that case presently not feasible. It is shown that distributions of scintillation light generated by proton or electron beams can be reconstructed by the dosimetry system within minutes. The quenching apparent for proton irradiation, and the yet not precisely determined position dependency of the imaging scale, require further investigation and corrections. Upgrading the prototype with larger or inorganic scintillators would increase the detectable proton and electron energy range. The presented results show that the determination of 3D dose distributions using scintillator blocks and optical tomography is a promising dosimetry method.
Lv, Yan; Yan, Bin; Wang, Lin; Lou, Dong-hua
2012-04-01
To analyze the reliability of the dento-maxillary models created by cone-beam CT and rapid prototyping (RP). Plaster models were obtained from 20 orthodontic patients who had been scanned by cone-beam CT and 3-D models were formed after the calculation and reconstruction of software. Then, computerized composite models (RP models) were produced by rapid prototyping technique. The crown widths, dental arch widths and dental arch lengths on each plaster model, 3-D model and RP model were measured, followed by statistical analysis with SPSS17.0 software package. For crown widths, dental arch lengths and crowding, there were significant differences(P<0.05) among the 3 models, but the dental arch widths were on the contrary. Measurements on 3-D models were significantly smaller than those on other two models(P<0.05). Compared with 3-D models, RP models had more numbers which were not significantly different from those on plaster models(P>0.05). The regression coefficient among three models were significantly different(P<0.01), ranging from 0.8 to 0.9. But between RP and plaster models was bigger than that between 3-D and plaster models. There is high consistency within 3 models, while some differences were accepted in clinic. Therefore, it is possible to substitute 3-D and RP models for plaster models in order to save storage space and improve efficiency.
Monitoring of Crew Activity with FAMOS
NASA Astrophysics Data System (ADS)
Wolf, L.; Cajochen, C.; Bromundt, V.
2007-10-01
The success of long duration space missions, such as manned missions to Mars, depends on high and sustained levels of vigilance and performance of astronauts and operators working in the technology rich environment of a spacecraft. Experiment 'Monitoring of Crew Activity with FAMOS' was set up to obtain operational experience with complimentary methods / technologies to assess the alertness / sleepiness status of selected AustroMars crewmembers on a daily basis. We applied a neurobehavioral test battery consisting of 1) Karolinska Sleepiness Scale KSS, 2) Karolinska Drowsiness Test KDT, 3) Psychomotor Vigilance Task PVT, combined with 4) left eye video recordings with an early prototype of the FAMOS Fatigue Monitoring System headset currently being developed by Sowoon Technologies (CH), and 5) Actiwatches that were worn continuously. A test battery required approximately 15 minutes and was repeated up to 4 times daily by 2 to 4 subjects. Here we present the data analysis of methods 1, 2, 3, and 5, while data analysis of method 4 is still in progress.
Terrell, D F; Thomas, R K
1990-09-01
In Experiment 1, with the number of sides or angles of irregular polygons as cues, programmed training, and a 90% correct criterion (36 of 40), 2 squirrel monkeys' (Saimiri sciureus sciureus and S. boliviensus boliviensus) best performances were to discriminate heptagons from octagons, a 3rd's best was hexagons from heptagons, and a 4th's best was pentagons from heptagons. In Experiment 2, on most trials 2 polygons on one or both discriminanda had to be summed to determine which discrimination had the total fewer sides. Only 1 monkey met criterion (27 of 30) on the 2 tasks, 6 vs. 8 and 7 vs. 8 sides, but the other 3 performed better than chance on the 6 vs. 8 task. We conclude that previous studies of animals' discrimination of polygons in terms of complexity were minimally relevant to this work, and counting and subitizing were rejected in favor of a prototype-matching process to explain our monkeys' performances.
Local Criticality and non-Fermi Liquid Behavior in Heavy Fermions
NASA Astrophysics Data System (ADS)
Si, Qimiao
2002-03-01
Quantum criticality provides a means to understand the apparent non-Fermi liquid phenomena in strongly correlated metals. Heavy fermion metals have emerged as a prototype system; many of them explicitly display a magnetic QCP. Experiments have shown that the quantum critical behavior is much richer than expected. One surprise came from neutron scattering, which found that the spin dynamics is anomalous not only near the antiferromagnetic wavevectors but also essentially everywhere in the Brillouin zone. In this talk, I will review the experiments and describe our theoretical work on the subject [1,2,3]. The notion of "local criticality" will be introduced and will be argued to apply to the heavy fermions. Some broader implications of the results will also be discussed. [1] Q. Si, S. Rabello, K. Ingersent, and J. L. Smith, Nature 413, 804 (2001). [2] Q. Si, J. L. Smith and K. Ingersent, Int. Journ. Mod. Phys. B13, 2331 (1999). [3] J. L. Smith and Q. Si, Phys. Rev. B61, 5184 (2000).
Prototypicality in Sentence Production
Onishi, Kristine H.; Murphy, Gregory L.; Bock, Kathryn
2008-01-01
Three cued-recall experiments examined the effect of category typicality on the ordering of words in sentence production. Past research has found that typical items tend to be mentioned before atypical items in a phrase—a pattern usually associated with lexical variables (like word frequency), and yet typicality is a conceptual variable. Experiment 1 revealed that an appropriate conceptual framework was necessary to yield the typicality effect. Experiment 2 tested ad-hoc categories that do not have prior representations in long-term memory and yielded no typicality effect. Experiment 3 used carefully matched sentences in which two category members appeared in the same or in different phrases. Typicality affected word order only when the two words appeared in the same phrase. These results are consistent with an account in which typicality has its origin in conceptual structure, which leads to differences in lexical accessibility in appropriate contexts. PMID:17631877
Wang, Shu-Yao; A, Ji-Ye; Fei, Fei; Geng, Jian-Liang; Peng, Ying; Ouyang, Bing-Chen; Wang, Pei; Jin, Xiao-Liang; Zhao, Yu-Qing; Wang, Jian-Kun; Geng, Ting; Li, Yan-Jing; Huang, Wen-Zhe; Wang, Zhen-Zhong; Xiao, Wei; Wang, Guang-Ji
2017-10-01
Ginkgo diterpene lactones meglumine injection (GDLI) is a commercially available product used for neuroprotection. However, the pharmacokinetic properties of the prototypes and hydrolyzed carboxylic forms of the primary components in GDLI, i.e., ginkgolide A (GA), ginkgolide B (GB), and ginkgolide K (GK), have never been fully evaluated in beagle dogs. In this work, a simple, sensitive, and reliable method based on ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) was developed, and the prototypes and total amounts of GA, GB, and GK were determined in beagle dog plasma. The plasma concentrations of the hydrolyzed carboxylic forms were calculated by subtracting the prototype concentrations from the total lactone concentrations. For the first time, the pharmacokinetics of GA, GB, and GK were fully assessed in three forms, i.e., the prototypes, the hydrolyzed carboxylic forms, and the total amounts, after intravenous administration of GDLI in beagle dogs. It was shown that ginkgolides primarily existed in the hydrolyzed form in plasma, and the ratio of hydrolysates to prototype forms of GA and GB decreased gradually to a homeostatic ratio. All of the three forms of the three ginkgolides showed linear exposure of AUC to the dosages. GA, GB, and GK showed a constant half-life approximately 2.7, 3.4, and 1.2 h, respectively, which were consistent for the forms at three dose levels (0.3, 1.0, and 3.0 mg·kg -1 ) and after a consecutive injection of GDLI for 7 days (1.0 mg·kg -1 ). Copyright © 2017 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
Del Fiol, Guilherme; Hanseler, Haley; Crouch, Barbara Insley; Cummins, Mollie R.
2016-01-01
Summary Background Health information exchange (HIE) between Poison Control Centers (PCCs) and Emergency Departments (EDs) could improve care of poisoned patients. However, PCC information systems are not designed to facilitate HIE with EDs; therefore, we are developing specialized software to support HIE within the normal workflow of the PCC using user-centered design and rapid prototyping. Objective To describe the design of an HIE dashboard and the refinement of user requirements through rapid prototyping. Methods Using previously elicited user requirements, we designed low-fidelity sketches of designs on paper with iterative refinement. Next, we designed an interactive high-fidelity prototype and conducted scenario-based usability tests with end users. Users were asked to think aloud while accomplishing tasks related to a case vignette. After testing, the users provided feedback and evaluated the prototype using the System Usability Scale (SUS). Results Survey results from three users provided useful feedback that was then incorporated into the design. After achieving a stable design, we used the prototype itself as the specification for development of the actual software. Benefits of prototyping included having 1) subject-matter experts heavily involved with the design; 2) flexibility to make rapid changes, 3) the ability to minimize software development efforts early in the design stage; 4) rapid finalization of requirements; 5) early visualization of designs; 6) and a powerful vehicle for communication of the design to the programmers. Challenges included 1) time and effort to develop the prototypes and case scenarios; 2) no simulation of system performance; 3) not having all proposed functionality available in the final product; and 4) missing needed data elements in the PCC information system. PMID:27081404
A Trustworthy Key Generation Prototype Based on DDR3 PUF for Wireless Sensor Networks
Liu, Wenchao; Zhang, Zhenhua; Li, Miaoxin; Liu, Zhenglin
2014-01-01
Secret key leakage in wireless sensor networks (WSNs) is a high security risk especially when sensor nodes are deployed in hostile environment and physically accessible to attackers. With nowadays semi/fully-invasive attack techniques attackers can directly derive the cryptographic key from non-volatile memory (NVM) storage. Physically Unclonable Function (PUF) is a promising technology to resist node capture attacks, and it also provides a low cost and tamper-resistant key provisioning solution. In this paper, we designed a PUF based on double-data-rate SDRAM Type 3 (DDR3) memory by exploring its memory decay characteristics. We also described a prototype of 128-bit key generation based on DDR3 PUF with integrated fuzzy extractor. Due to the wide adoption of DDR3 memory in WSN, our proposed DDR3 PUF technology with high security levels and no required hardware changes is suitable for a wide range of WSN applications. PMID:24984058
3D-printing technologies for electrochemical applications.
Ambrosi, Adriano; Pumera, Martin
2016-05-21
Since its conception during the 80s, 3D-printing, also known as additive manufacturing, has been receiving unprecedented levels of attention and interest from industry and research laboratories. This is in addition to end users, who have benefited from the pervasiveness of desktop-size and relatively cheap printing machines available. 3D-printing enables almost infinite possibilities for rapid prototyping. Therefore, it has been considered for applications in numerous research fields, ranging from mechanical engineering, medicine, and materials science to chemistry. Electrochemistry is another branch of science that can certainly benefit from 3D-printing technologies, paving the way for the design and fabrication of cheaper, higher performing, and ubiquitously available electrochemical devices. Here, we aim to provide a general overview of the most commonly available 3D-printing methods along with a review of recent electrochemistry related studies adopting 3D-printing as a possible rapid prototyping fabrication tool.
Femur Model Reconstruction Based on Reverse Engineering and Rapid Prototyping
NASA Astrophysics Data System (ADS)
Tang, Tongming; Zhang, Zheng; Ni, Hongjun; Deng, Jiawen; Huang, Mingyu
Precise reconstruction of 3D models is fundamental and crucial to the researches of human femur. In this paper we present our approach towards tackling this problem. The surface of a human femur was scanned using a hand-held 3D laser scanner. The data obtained, in the form of point cloud, was then processed using the reverse engineering software Geomagic and the CAD/CAM software CimatronE to reconstruct a digital 3D model. The digital model was then used by the rapid prototyping machine to build a physical model of human femur using 3D printing. The geometric characteristics of the obtained physical model matched that of the original femur. The process of "physical object - 3D data - digital 3D model - physical model" presented in this paper provides a foundation of precise modeling for the digital manufacturing, virtual assembly, stress analysis, and simulated surgery of artificial bionic femurs.
NASA Astrophysics Data System (ADS)
Stock, Michael; Barat, Pauline; Davis, Richard S.; Picard, Alain; Milton, Martin J. T.
2015-04-01
This report presents the results of the first phase of the campaign of calibration carried out with respect to the international prototype of the kilogram (IPK) in anticipation of the redefinition of the kilogram (Extraordinary Calibrations). The definition of the kilogram was realized according to the procedure outlined in the 8th Edition of the SI Brochure. Thus the IPK and its six official copies have been cleaned and washed following the BIPM procedure. The mass comparisons carried out during this campaign showed a very good repeatability. The pooled standard deviation of repeated weighings of the prototypes was 0.4 µg. The effect of cleaning and washing of the IPK was to remove a mass of 16.8 µg. The effect of cleaning and washing of the six official copies was found to be very similar, giving an average mass removed from the seven prototypes of 15 µg with a standard deviation of 2 µg. The differences in mass between the IPK and the official copies have changed by an average of 1 µg since the 3rd Periodic Verification of National Prototypes of the Kilogram (1988-1992). These results do not confirm the trend for the masses of the six official copies to diverge from the mass of the IPK that was observed during the 2nd and 3rd Periodic Verifications. All BIPM working standards and the prototypes reserved for special use have been calibrated with respect to the IPK as part of this campaign. All of them were found to have lower masses than when they were calibrated during the 3rd Periodic Verification. As a consequence, the BIPM ‘as-maintained’ mass unit in 2014 has been found to be offset by 35 µg with respect to the IPK. This result will be analyzed in a further publication.
Precision tracking with a single gaseous pixel detector
NASA Astrophysics Data System (ADS)
Tsigaridas, S.; van Bakel, N.; Bilevych, Y.; Gromov, V.; Hartjes, F.; Hessey, N. P.; de Jong, P.; Kluit, R.
2015-09-01
The importance of micro-pattern gaseous detectors has grown over the past few years after successful usage in a large number of applications in physics experiments and medicine. We develop gaseous pixel detectors using micromegas-based amplification structures on top of CMOS pixel readout chips. Using wafer post-processing we add a spark-protection layer and a grid to create an amplification region above the chip, allowing individual electrons released above the grid by the passage of ionising radiation to be recorded. The electron creation point is measured in 3D, using the pixel position for (x, y) and the drift time for z. The track can be reconstructed by fitting a straight line to these points. In this work we have used a pixel-readout-chip which is a small-scale prototype of Timepix3 chip (designed for both silicon and gaseous detection media). This prototype chip has several advantages over the existing Timepix chip, including a faster front-end (pre-amplifier and discriminator) and a faster TDC which reduce timewalk's contribution to the z position error. Although the chip is very small (sensitive area of 0.88 × 0.88mm2), we have built it into a detector with a short drift gap (1.3 mm), and measured its tracking performance in an electron beam at DESY. We present the results obtained, which lead to a significant improvement for the resolutions with respect to Timepix-based detectors.
Deployment of an Ecosystem Warming Prototype at the Fairbanks Permafrost Experiment Station
NASA Astrophysics Data System (ADS)
Wagner, A. M.; Zufelt, J. E.; Wullschleger, S. D.
2010-12-01
Controlled experiments in terrestrial ecosystems are necessary to understand how changes in climate may affect the interactions among physical, chemical, and biological parameters. Advanced approaches to above and below ground warming will improve our understanding of the biotic and abiotic processes that govern plant and soil response to climatic change in terrestrial ecosystems. A prototype concept for raising soil temperatures in large outdoor plots has been developed at Oak Ridge National Laboratory. The performance of this design has been field-tested in 3-m diameter plots in a temperate deciduous forest and also numerically simulated for experimental plots ranging from 3 to 20 m in diameter. The goal of the present study is to determine if the prototype system can be used to increase the temperature of permafrost soils in arctic and sub-arctic climates. Two sites in Alaska have been selected (Fairbanks and Barrow) for installation and testing of 20-meter diameter plots beginning in the fall of 2010. Fairbanks has a continental climate, with a mean annual air temperature of -3.3°C, mean annual precipitation of 287 mm, and relatively warm (-1 to -2°C) permafrost temperatures. Barrow is located within the Alaskan Arctic coastal plain and has a mean annual air temperature of -12.6°C, mean annual precipitation of 124 mm, and colder (-8 to -12°C) permafrost temperatures. This presentation focuses on the study site located at the U.S. Army Cold Regions Research and Engineering Laboratory Permafrost Experiment Station, Fairbanks. The experiment station was established in 1945 and consists of 135 acres of ice-rich permafrost soils generally present to a depth of 60 m with an active layer that varies from 55 to 85 cm in undisturbed areas. The site has a smooth, gentle slope to the west, providing good surface drainage except at the lowest elevations where saturated conditions can exist. Soils consist of tan silt and wind blown loess near the surface and grey silt at depths below 1.4 m. Permafrost moisture contents range from 26 to 41 percent by mass for the frozen silts which makes this relatively low moisture content permafrost. Vegetation is typical of the Alaskan Interior-subarctic taiga forest with white spruce (Picea glauca [Moench] Voss), and black spruce (P. mariana [Mill] B.S.P) interspersed with lowbush cranberry (Vaccinium oxycoccos L.) and Labrador tea (Ledum groenlandicum Oeder). Feather moss and sphagnum moss are present in the understory. The experimental plot is a hexagonal shaped area (29 by 25 m) where vegetation had previously been removed but has regrown over the last 40-50 years. Soil warming is accomplished by 127 vertically-installed low-energy heating elements installed at spacing of 2.4 m and to a depth of 4 m. Only the lower 1-m is heated to a setpoint +4°C above ambient. The heated area includes a buffer zone resulting in a test area with a diameter of 20 m. This proof-of-concept study will result in improvements to experimental design and thermal modeling ground-truth data as the scientific community plans for possible next-generation climate change experiments in terrestrial permafrost ecosystems.
Development and evaluation of a prototype life preserver.
DOT National Transportation Integrated Search
1985-09-01
The purpose of this study was to develop a prototype life preserver that included provisions for: : 1.increased thermal protection in the event of accidental immersion in cold water, : 2.35 pounds of buoyancy, : 3.a doning [sic] time of 15 s for an a...
Hardware Support for Malware Defense and End-to-End Trust
2017-02-01
IoT) sensors and actuators, mobile devices and servers; cloud based, stand alone, and traditional mainframes. The prototype developed demonstrated...virtual machines. For mobile platforms we developed and prototyped an architecture supporting separation of personalities on the same platform...4 3.1. MOBILE
NASA Technical Reports Server (NTRS)
Tanner, Alan B.; Lambrigsten, B. H.; Brown, S. T.; Wilson, W. J.; Piepmeier, J. R.; Ruf, C. S.; Lim, B.
2006-01-01
A viewgraph presentation of a prototype Geostationary Synthetic Thinned Aperture Radiometer (GeoSTAR) for atmospheric temperature sounding is shown. The topics include: 1) Overview; 2) Requirements & Error allocations; 3) Design; 4) Problems, and How We Solved Them; and 5) Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krock, L.P.; Navalta, R.; Myhre, L.G.
An open bilayer ground-crew chemical defense ensemble (CDE) was proposed to reduce the thermal burden during vapor-only exposure periods. This study compared the thermal-stress profile of the proposed ensemble to that produced by the currently employed closed CDE. Four subjects, alternating ensembles on separate days, walked on a treadmill in an environmental chamber at 5.3 km/h (3.3 mph) and 2% grade (an energy expenditure of 350 kcal/h) for alternating work/rest to achieve significant recovery. Mean total sweat production was lower (1.38 vs. 2.50 liters) and percent sweat evaporation greater (65.7% vs. 30.0%) in the prototype ensemble than in the CDE.more » The prototype ensemble provided greater heat dissipation and allowed more-efficient sweat evaporation which had the double benefit of reducing heat storage and limiting dehydration.« less
NASA Astrophysics Data System (ADS)
de Souza, Gabriel Fernandes; Tan, Lippong; Singh, Baljit; Ding, Lai Chet; Date, Abhijit
2017-04-01
The paper presents a sustainable hybrid system, which is capable of generating electricity and producing freshwater from seawater using low grade heat source. This proposed system uses low grade heat that can be supplied from solar radiation, industrial waste heat or any other waste heat sources where the temperature is less than 150°C. The concept behind this system uses the Seebeck effect for thermoelectricity generation via incorporating the low boiling point of seawater under sub-atmospheric ambient pressure. A lab-test prototype of the proposed system was built and experimentally tested in RMIT University. The prototype utilised four commercial available thermoelectric generators (Bi2Te3) and a vacuum vessel to achieve the simultaneous production of electricity and freshwater. The temperature profiles, thermoelectric powers and freshwater productions were determined at several levels of salinity to study the influence of different salt concentrations. The theoretical description of system design and experimental results were analysed and discussed in detailed. The experiment results showed that 0.75W of thermoelectricity and 404g of freshwater were produced using inputs of 150W of simulated waste heat and 500g of 3% saline water. The proposed hybrid concept has demonstrated the potential to become the future sustainable system for electricity and freshwater productions.
High speed superconducting flywheel system for energy storage
NASA Astrophysics Data System (ADS)
Bornemann, H. J.; Urban, C.; Boegler, P.; Ritter, T.; Zaitsev, O.; Weber, K.; Rietschel, H.
1994-12-01
A prototype of a flywheel system with auto stable high temperature superconducting bearings was built and tested. The bearings offered good vertical and lateral stability. A metallic flywheel disk, ø 190 mm x 30 mm, was safely rotated at speeds up to 15000 rpm. The disk was driven by a 3 phase synchronous homopolar motor/generator. Maximum energy capacity was 3.8 Wh, maximum power was 1.5 KW. The dynamic behavior of the prototype was tested, characterized and evaluated with respect to axial and lateral stiffness, decay torques (bearing drag), vibrational modes and critical speeds. The bearings supports a maximum weight of 65 N at zero gap, axial and lateral stiffness at 1 mm gap were 440 N/cm and 130 N/cm, respectively. Spin down experiments were performed to investigate the energy efficiency of the system. The decay rate was found to depend upon background pressure in the vacuum chamber and upon the gap width in the bearing. At a background pressure of 5x10 -4 Torr, the coefficient of friction (drag-to-lift ratio) was measured to be 0.000009 at low speeds for 6 mm gap width in the bearing. Our results indicate that further refinement of this technology will allow operation of higly efficient superconducting flywheels in the kWh range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuechler, Erich R.; Department of Chemistry, University of Minnesota, Minneapolis, Minnesota 55455-0431; York, Darrin M., E-mail: york@biomaps.rutgers.edu
2014-02-07
The nucleophilic attack of a chloride ion on methyl chloride is an important prototype S{sub N}2 reaction in organic chemistry that is known to be sensitive to the effects of the surrounding solvent. Herein, we develop a highly accurate Specific Reaction Parameter (SRP) model based on the Austin Model 1 Hamiltonian for chlorine to study the effects of solvation into an aqueous environment on the reaction mechanism. To accomplish this task, we apply high-level quantum mechanical calculations to study the reaction in the gas phase and combined quantum mechanical/molecular mechanical simulations with TIP3P and TIP4P-ew water models and the resultingmore » free energy profiles are compared with those determined from simulations using other fast semi-empirical quantum models. Both gas phase and solution results with the SRP model agree very well with experiment and provide insight into the specific role of solvent on the reaction coordinate. Overall, the newly parameterized SRP Hamiltonian is able to reproduce both the gas phase and solution phase barriers, suggesting it is an accurate and robust model for simulations in the aqueous phase at greatly reduced computational cost relative to comparably accurate ab initio and density functional models.« less
NASA Astrophysics Data System (ADS)
Kuechler, Erich R.; York, Darrin M.
2014-02-01
The nucleophilic attack of a chloride ion on methyl chloride is an important prototype SN2 reaction in organic chemistry that is known to be sensitive to the effects of the surrounding solvent. Herein, we develop a highly accurate Specific Reaction Parameter (SRP) model based on the Austin Model 1 Hamiltonian for chlorine to study the effects of solvation into an aqueous environment on the reaction mechanism. To accomplish this task, we apply high-level quantum mechanical calculations to study the reaction in the gas phase and combined quantum mechanical/molecular mechanical simulations with TIP3P and TIP4P-ew water models and the resulting free energy profiles are compared with those determined from simulations using other fast semi-empirical quantum models. Both gas phase and solution results with the SRP model agree very well with experiment and provide insight into the specific role of solvent on the reaction coordinate. Overall, the newly parameterized SRP Hamiltonian is able to reproduce both the gas phase and solution phase barriers, suggesting it is an accurate and robust model for simulations in the aqueous phase at greatly reduced computational cost relative to comparably accurate ab initio and density functional models.
Kuechler, Erich R; York, Darrin M
2014-02-07
The nucleophilic attack of a chloride ion on methyl chloride is an important prototype SN2 reaction in organic chemistry that is known to be sensitive to the effects of the surrounding solvent. Herein, we develop a highly accurate Specific Reaction Parameter (SRP) model based on the Austin Model 1 Hamiltonian for chlorine to study the effects of solvation into an aqueous environment on the reaction mechanism. To accomplish this task, we apply high-level quantum mechanical calculations to study the reaction in the gas phase and combined quantum mechanical/molecular mechanical simulations with TIP3P and TIP4P-ew water models and the resulting free energy profiles are compared with those determined from simulations using other fast semi-empirical quantum models. Both gas phase and solution results with the SRP model agree very well with experiment and provide insight into the specific role of solvent on the reaction coordinate. Overall, the newly parameterized SRP Hamiltonian is able to reproduce both the gas phase and solution phase barriers, suggesting it is an accurate and robust model for simulations in the aqueous phase at greatly reduced computational cost relative to comparably accurate ab initio and density functional models.
Micro-optical system based 3D imaging for full HD depth image capturing
NASA Astrophysics Data System (ADS)
Park, Yong-Hwa; Cho, Yong-Chul; You, Jang-Woo; Park, Chang-Young; Yoon, Heesun; Lee, Sang-Hun; Kwon, Jong-Oh; Lee, Seung-Wan
2012-03-01
20 Mega-Hertz-switching high speed image shutter device for 3D image capturing and its application to system prototype are presented. For 3D image capturing, the system utilizes Time-of-Flight (TOF) principle by means of 20MHz high-speed micro-optical image modulator, so called 'optical shutter'. The high speed image modulation is obtained using the electro-optic operation of the multi-layer stacked structure having diffractive mirrors and optical resonance cavity which maximizes the magnitude of optical modulation. The optical shutter device is specially designed and fabricated realizing low resistance-capacitance cell structures having small RC-time constant. The optical shutter is positioned in front of a standard high resolution CMOS image sensor and modulates the IR image reflected from the object to capture a depth image. Suggested novel optical shutter device enables capturing of a full HD depth image with depth accuracy of mm-scale, which is the largest depth image resolution among the-state-of-the-arts, which have been limited up to VGA. The 3D camera prototype realizes color/depth concurrent sensing optical architecture to capture 14Mp color and full HD depth images, simultaneously. The resulting high definition color/depth image and its capturing device have crucial impact on 3D business eco-system in IT industry especially as 3D image sensing means in the fields of 3D camera, gesture recognition, user interface, and 3D display. This paper presents MEMS-based optical shutter design, fabrication, characterization, 3D camera system prototype and image test results.
Dynamic cell culture system: a new cell cultivation instrument for biological experiments in space
NASA Technical Reports Server (NTRS)
Gmunder, F. K.; Nordau, C. G.; Tschopp, A.; Huber, B.; Cogoli, A.
1988-01-01
The prototype of a miniaturized cell cultivation instrument for animal cell culture experiments aboard Spacelab is presented (Dynamic cell culture system: DCCS). The cell chamber is completely filled and has a working volume of 200 microliters. Medium exchange is achieved with a self-powered osmotic pump (flowrate 1 microliter h-1). The reservoir volume of culture medium is 230 microliters. The system is neither mechanically stirred nor equipped with sensors. Hamster kidney (Hak) cells growing on Cytodex 3 microcarriers were used to test the biological performance of the DCCS. Growth characteristics in the DCCS, as judged by maximal cell density, glucose consumption, lactic acid secretion and pH, were similar to those in cell culture tubes.
Topological signature in the NEXT high pressure xenon TPC
NASA Astrophysics Data System (ADS)
Ferrario, Paola;
2017-09-01
The NEXT experiment aims to observe the neutrinoless double beta decay of 136Xe in a high-pressure xenon gas TPC using electroluminescence to amplify the signal from ionization. One of the main advantages of this technology is the possibility to use the topology of events with energies close to Qββ as an extra tool to reject background. In these proceedings we show with data from prototypes that an extra background rejection factor of 24.3 ± 1.4 (stat.)% can be achieved, while maintaining an efficiency of 66.7 ± 1.% for signal events. The performance expected in NEW, the next stage of the experiment, is to improve to 12.9% ± 0.6% background acceptance for 66.9% ± 0.6% signal efficiency.
Small-strip Thin Gap Chambers for the muon spectrometer upgrade of the ATLAS experiment
NASA Astrophysics Data System (ADS)
Perez Codina, E.; ATLAS Muon Collaboration
2016-07-01
The ATLAS muon system upgrade to be installed during the LHC long shutdown in 2018/19, the so-called New Small Wheel (NSW), is designed to cope with the increased instantaneous luminosity in LHC Run 3. The small-strip Thin Gap Chambers (sTGC) will provide the NSW with a fast trigger and high precision tracking. The construction protocol has been validated by test beam experiments on a full-size prototype sTGC detector, showing the performance requirements are met. The intrinsic spatial resolution for a single layer has been found to be about 45 μm for a perpendicular incident angle, and the transition region between pads has been measured to be about 4 mm.
Integration of Pneumatic Technology in Powered Mobility Devices
Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G.; Schneider, Urs
2017-01-01
Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs. PMID:29339888
Integration of Pneumatic Technology in Powered Mobility Devices.
Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G; Schneider, Urs; Cooper, Rory A
2017-01-01
Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs.
Neural basis of scientific innovation induced by heuristic prototype.
Luo, Junlong; Li, Wenfu; Qiu, Jiang; Wei, Dongtao; Liu, Yijun; Zhang, Qinlin
2013-01-01
A number of major inventions in history have been based on bionic imitation. Heuristics, by applying biological systems to the creation of artificial devices and machines, might be one of the most critical processes in scientific innovation. In particular, prototype heuristics propositions that innovation may engage automatic activation of a prototype such as a biological system to form novel associations between a prototype's function and problem-solving. We speculated that the cortical dissociation between the automatic activation and forming novel associations in innovation is critical point to heuristic creativity. In the present study, novel and old scientific innovations (NSI and OSI) were selected as experimental materials in using learning-testing paradigm to explore the neural basis of scientific innovation induced by heuristic prototype. College students were required to resolve NSI problems (to which they did not know the answers) and OSI problems (to which they knew the answers). From two fMRI experiments, our results showed that the subjects could resolve NSI when provided with heuristic prototypes. In Experiment 1, it was found that the lingual gyrus (LG; BA18) might be related to prototype heuristics in college students resolving NSI after learning a relative prototype. In Experiment 2, the LG (BA18) and precuneus (BA31) were significantly activated for NSI compared to OSI when college students learned all prototypes one day before the test. In addition, the mean beta-values of these brain regions of NSI were all correlated with the behavior accuracy of NSI. As our hypothesis indicated, the findings suggested that the LG might be involved in forming novel associations using heuristic information, while the precuneus might be involved in the automatic activation of heuristic prototype during scientific innovation.
Neural Basis of Scientific Innovation Induced by Heuristic Prototype
Qiu, Jiang; Wei, Dongtao; Liu, Yijun; Zhang, Qinlin
2013-01-01
A number of major inventions in history have been based on bionic imitation. Heuristics, by applying biological systems to the creation of artificial devices and machines, might be one of the most critical processes in scientific innovation. In particular, prototype heuristics propositions that innovation may engage automatic activation of a prototype such as a biological system to form novel associations between a prototype's function and problem-solving. We speculated that the cortical dissociation between the automatic activation and forming novel associations in innovation is critical point to heuristic creativity. In the present study, novel and old scientific innovations (NSI and OSI) were selected as experimental materials in using learning-testing paradigm to explore the neural basis of scientific innovation induced by heuristic prototype. College students were required to resolve NSI problems (to which they did not know the answers) and OSI problems (to which they knew the answers). From two fMRI experiments, our results showed that the subjects could resolve NSI when provided with heuristic prototypes. In Experiment 1, it was found that the lingual gyrus (LG; BA18) might be related to prototype heuristics in college students resolving NSI after learning a relative prototype. In Experiment 2, the LG (BA18) and precuneus (BA31) were significantly activated for NSI compared to OSI when college students learned all prototypes one day before the test. In addition, the mean beta-values of these brain regions of NSI were all correlated with the behavior accuracy of NSI. As our hypothesis indicated, the findings suggested that the LG might be involved in forming novel associations using heuristic information, while the precuneus might be involved in the automatic activation of heuristic prototype during scientific innovation. PMID:23372641
NASA Technical Reports Server (NTRS)
Bueker, P. A.
1982-01-01
The Nitrogen Washout System measures nitrogen elimination on a breath basis from the body tissues of a subject breathing pure oxygen. The system serves as a prototype for a Space Shuttle Life Sciences experiment and in the Environmental Physiology Laboratory. Typically, a subject washes out body nitrogen for three hours while breathing oxygen from a mask enclosed in a positive-pressure oxygen tent. A nitrogen washout requires one test operator and the test subject. A DEC LSI-11/02 computer is used to (1) control and calibrate the mass spectrometer and Skylab spirometer, (2) gather and store experimental data and (3) provide limited real time analysis and more extensive post-experiment analysis. Five programs are used to gather and store the experimental data and perform all the real time control and analysis.
On the use of a (252Cf-3He) assembly for landmine detection by the neutron back-scattering method.
Elsheikh, N; Viesti, G; ElAgib, I; Habbani, F
2012-04-01
Experiments were carried out to optimize the performance of the neutron back-scattering (NBS) technique in landmine detection using an assembly consisting of three different layers placed above a (252)Cf neuron source, producing about 10(4)s(-1), in conjunction with a (3)He detector. The assembly was optimized experimentally. The selected assembly configuration was then examined against different (252)Cf stand-off distances and mine burial depths using dummy landmines. Furthermore, Monte Carlo simulations were performed to study the effect of the shield when a (252)Cf source in the range 10(4)-10(7)s(-1) was employed, and to optimize the geometry for future prototypes. Copyright © 2012 Elsevier Ltd. All rights reserved.
Nanoimprint Lithography on curved surfaces prepared by fused deposition modelling
NASA Astrophysics Data System (ADS)
Köpplmayr, Thomas; Häusler, Lukas; Bergmair, Iris; Mühlberger, Michael
2015-06-01
Fused deposition modelling (FDM) is an additive manufacturing technology commonly used for modelling, prototyping and production applications. The achievable surface roughness is one of its most limiting aspects. It is however of great interest to create well-defined (nanosized) patterns on the surface for functional applications such as optical effects, electronics or bio-medical devices. We used UV-curable polymers of different viscosities and flexible stamps made of poly(dimethylsiloxane) (PDMS) to perform Nanoimprint Lithography (NIL) on FDM-printed curved parts. Substrates with different roughness and curvature were prepared using a commercially available 3D printer. The nanoimprint results were characterized by optical light microscopy, profilometry and atomic force microscopy (AFM). Our experiments show promising results in creating well-defined microstructures on the 3D-printed parts.
Reducing wall plasma expansion with gold foam irradiated by laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Lu; Ding, Yongkun, E-mail: ding-yk@vip.sina.com; Jiang, Shaoen, E-mail: jiangshn@vip.sina.com
The experimental study on the expanding plasma movement of low-density gold foam (∼1% solid density) irradiated by a high power laser is reported in this paper. Experiments were conducted using the SG-III prototype laser. Compared to solid gold with 19.3 g/cc density, the velocities of X-ray emission fronts moving off the wall are much smaller for gold foam with 0.3 g/cc density. Theoretical analysis and MULTI 1D simulation results also show less plasma blow-off, and that the density contour movement velocities of gold foam are smaller than those of solid gold, agreeing with experimental results. These results indicate that foam walls havemore » advantages in symmetry control and lowering plasma fill when used in ignition hohlraum.« less
Study of a 3×3 module array of the ECAL0 calorimeter with an electron beam at the ELSA
NASA Astrophysics Data System (ADS)
Dziewiecki, M.; Anfimov, N.; Anosov, V.; Barth, J.; Chalyshev, V.; Chirikov-Zorin, I.; Elsner, D.; Frolov, V.; Frommberger, F.; Guskov, A.; Klein, F.; Krumshteyn, Z.; Kurjata, R.; Marzec, J.; Nagaytsev, A.; Olchevski, A.; Orlov, I.; Rybnikov, A.; Rychter, A.; Selyunin, A.; Zaremba, K.; Ziembicki, M.
2015-02-01
ECAL0 is a new electromagnetic calorimeter designed for studying generalized parton distributions at the COMPASS II experiment at CERN. It will be located next to the target and will cover larger photon angles (up to 30 degrees). It is a modular high-granularity Shashlyk device with total number of individual channels of approx. 1700 and readout based on wavelength shifting fibers and micropixel avalanche photodiodes. Characterization of the calorimeter includes tests of particular sub-components, tests of complete modules and module arrays, as well as a pilot run of a fully-functional, quarter-size prototype in the COMPASS experiment. The main goals of the tests on low-intensity electron beam at the ELSA accelerator in Bonn were: to provide energy calibration using electrons, to measure angular response of the calorimeter and to perform an energy scan to cross-check previously collected data. A dedicated measurement setup was prepared for the tests, including a 3x3 array of the ECAL0 modules, a scintillating-fibre hodoscope and a remotely-controlled motorized movable platform. The measurements were performed using three electron energies: 3.2 GeV, 1.6 GeV and 0.8 GeV. They include a calibration of the whole detector array with a straight beam and multiple angular scans.
Wilson Cluster; First Light in T-1007 Prototype Optical Cavity for Holometer/Axions Tuesday, May 3 3:30 Mieland, Fermilab ES&H, and will take place from noon to 12:45 p.m. on Tuesday, May 3, in Wilson Hall
Prototype and Chimera-Type Galectins in Placentas with Spontaneous and Recurrent Miscarriages.
Unverdorben, Laura; Haufe, Thomas; Santoso, Laura; Hofmann, Simone; Jeschke, Udo; Hutter, Stefan
2016-04-28
Galectins are galactose binding proteins and, in addition, factors for a wide range of pathologies in pregnancy. We have analyzed the expression of prototype (gal-1, -2, -7, -10) and chimera-type (gal-3) galectins in the placenta in cases of spontaneous abortions (SPA) and recurrent abortions (RA) in the first trimester. Fifteen placental samples from healthy pregnancies were used as a control group. Nine placentas were examined for spontaneous abortions, and 12 placentas for recurrent abortions. For differentiation and evaluation of different cell types of galectin-expression in the decidua, immunofluorescence was used. For all investigated prototype galectins (gal-1, -2, -7, -10) in SPA and RA placenta trophoblast cells the expression is significantly decreased. In the decidua/extravillous trophoblast only gal-2 expression was significantly lowered, which could be connected to its role in angiogenesis. In trophoblasts in first-trimester placentas and in cases of SPA and RA, prototype galectins are altered in the same way. We suspect prototype galectins have a similar function in placental tissue because of their common biochemical structure. Expression of galectin 3 as a chimera type galectin was not found to be significantly altered in abortive placentas.
Prototype and Chimera-Type Galectins in Placentas with Spontaneous and Recurrent Miscarriages
Unverdorben, Laura; Haufe, Thomas; Santoso, Laura; Hofmann, Simone; Jeschke, Udo; Hutter, Stefan
2016-01-01
Galectins are galactose binding proteins and, in addition, factors for a wide range of pathologies in pregnancy. We have analyzed the expression of prototype (gal-1, -2, -7, -10) and chimera-type (gal-3) galectins in the placenta in cases of spontaneous abortions (SPA) and recurrent abortions (RA) in the first trimester. Fifteen placental samples from healthy pregnancies were used as a control group. Nine placentas were examined for spontaneous abortions, and 12 placentas for recurrent abortions. For differentiation and evaluation of different cell types of galectin-expression in the decidua, immunofluorescence was used. For all investigated prototype galectins (gal-1, -2, -7, -10) in SPA and RA placenta trophoblast cells the expression is significantly decreased. In the decidua/extravillous trophoblast only gal-2 expression was significantly lowered, which could be connected to its role in angiogenesis. In trophoblasts in first-trimester placentas and in cases of SPA and RA, prototype galectins are altered in the same way. We suspect prototype galectins have a similar function in placental tissue because of their common biochemical structure. Expression of galectin 3 as a chimera type galectin was not found to be significantly altered in abortive placentas. PMID:27136536
Evolution of ferromagnetism in two-dimensional electron gas of LaTiO3/SrTiO3
NASA Astrophysics Data System (ADS)
Wen, Fangdi; Cao, Yanwei; Liu, Xiaoran; Pal, B.; Middey, S.; Kareev, M.; Chakhalian, J.
2018-03-01
Understanding, creating, and manipulating spin polarization of two-dimensional electron gases at complex oxide interfaces present an experimental challenge. For example, despite almost a decade long research effort, the microscopic origin of ferromagnetism in LaAlO3/SrTiO3 heterojunctions is still an open question. Here, by using a prototypical two-dimensional electron gas (2DEG) which emerges at the interface between band insulator SrTiO3 and antiferromagnetic Mott insulator LaTiO3, the experiment reveals the evidence for magnetic phase separation in a hole-doped Ti d1 t2g system, resulting in spin-polarized 2DEG. The details of electronic and magnetic properties of the 2DEG were investigated by temperature-dependent d.c. transport, angle-dependent X-ray photoemission spectroscopy, and temperature-dependent magnetoresistance. The observation of clear hysteresis in magnetotransport at low magnetic fields implies spin-polarization from magnetic islands in the hole rich LaTiO3 near the interface. These findings emphasize the role of magnetic instabilities in doped Mott insulators, thus providing another path for designing all-oxide structures relevant to spintronic applications.
Yitzhak, Neta; Giladi, Nir; Gurevich, Tanya; Messinger, Daniel S; Prince, Emily B; Martin, Katherine; Aviezer, Hillel
2017-12-01
According to dominant theories of affect, humans innately and universally express a set of emotions using specific configurations of prototypical facial activity. Accordingly, thousands of studies have tested emotion recognition using sets of highly intense and stereotypical facial expressions, yet their incidence in real life is virtually unknown. In fact, a commonplace experience is that emotions are expressed in subtle and nonprototypical forms. Such facial expressions are at the focus of the current study. In Experiment 1, we present the development and validation of a novel stimulus set consisting of dynamic and subtle emotional facial displays conveyed without constraining expressers to using prototypical configurations. Although these subtle expressions were more challenging to recognize than prototypical dynamic expressions, they were still well recognized by human raters, and perhaps most importantly, they were rated as more ecological and naturalistic than the prototypical expressions. In Experiment 2, we examined the characteristics of subtle versus prototypical expressions by subjecting them to a software classifier, which used prototypical basic emotion criteria. Although the software was highly successful at classifying prototypical expressions, it performed very poorly at classifying the subtle expressions. Further validation was obtained from human expert face coders: Subtle stimuli did not contain many of the key facial movements present in prototypical expressions. Together, these findings suggest that emotions may be successfully conveyed to human viewers using subtle nonprototypical expressions. Although classic prototypical facial expressions are well recognized, they appear less naturalistic and may not capture the richness of everyday emotional communication. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Use of prototyping in preoperative planning for patients with head and neck tumors.
de Farias, Terence Pires; Dias, Fernando Luiz; Galvão, Mário Sérgio; Boasquevisque, Edson; Pastl, Ana Carolina; Albuquerque Sousa, Bruno
2014-12-01
Prototyping technologies for reconstructions consist of obtaining a 3-dimensional model of the object of interest. Solid models are constructed by the deposition of materials in successive layers. The purpose of this study was to perform a double-blind, randomized, prospective study to evaluate the efficacy of prototype use in head and neck surgeries. Thirty-seven cases were randomized into prototype and nonprototype groups. The following factors were recorded: the time of plate and locking screw apposition, flap size, time for reconstruction, and an aesthetic evaluation. The prototype group exhibited a reduced surgical time (43.7 minutes vs 127.7 minutes, respectively; p = .001), a tendency to reduce the size of the bone flap taken for reconstruction, and better aesthetic results than the group that was not prototyped. The use of prototyping demonstrated a trend toward a reduced surgical time, smaller bone flaps, and better aesthetic results. © 2014 Wiley Periodicals, Inc.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 1 2010-07-01 2010-07-01 false Background. 3.2 Section 3.2 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE ACQUISITION TRANSACTIONS OTHER THAN CONTRACTS, GRANTS, OR COOPERATIVE AGREEMENTS FOR PROTOTYPE PROJECTS § 3.2 Background. “Other transactions” is the...
Subjective and objective analysis of three water pump systems carried by forest firefighters.
Moser, Daniel J; Graham, Ryan B; Stevenson, Joan M; Costigan, Patrick A
2014-01-01
The Mark 3 (M3) water power pump is an integral piece of wildfire fighting equipment. However, it is provided to fire stations without a carrying harness. The currently-used carrying harness is very uncomfortable, especially when carrying the pumps considerable distance in a forest to reach a water source. The purpose of this study was to advise the Ontario Ministry of Natural Resources on the selection of a new M3 load carriage system. Twenty Fire Rangers wore the three systems (Original, Prototype, and Modified) through a circuit of tasks representative of their working environment. Subjective and objective approaches were combined to assess and rank the M3 carriage systems. Subjective visual analogue scale ratings were obtained for ease of loading/unloading, comfort, system stability, and overall performance. Tri-axial accelerometers were mounted on each pump and at the sternum of each participant to determine relative pump-carrier accelerations. Overall, the Prototype was ranked as the best system; it resulted in the lowest relative pump-carrier accelerations on 10 out of 15 objective measures, and also received a first place ranking on all subjective measures. It was recommended that the Prototype be implemented as the M3 carriage system for fire suppression teams.
Paczynski, Martin; Kuperberg, Gina R.
2011-01-01
Animacy is known to play an important role in language processing and production, but debate remains as to how it exerts its effects: 1) through links to syntactic ordering, 2) through inherent differences between animate and inanimate entities in their salience/lexico-semantic accessibility, 3) through links to specific thematic roles. We contrasted these three accounts in two event related potential (ERP) experiments examining the processing of direct object arguments in simple English sentences. In Experiment 1, we found a larger N400 to animate than inanimate direct object arguments assigned the Patient role, ruling out the second account. In Experiment 2 we found no difference in the N400 evoked by animate direct object arguments assigned the Patient role (prototypically inanimate) and those assigned the Experiencer role (prototypically animate), ruling out the third account. We therefore suggest that animacy may impact processing through a direct link to syntactic linear ordering, at least on post-verbal arguments in English. We also examined processing on direct object arguments that violated the animacy-based selection restriction constraints of their preceding verbs. These violations evoked a robust P600, which was not modulated by thematic role assignment or reversibility, suggesting that the so-called semantic P600 is driven by overall propositional impossibility, rather than thematic role reanalysis. PMID:22199415
NASA Astrophysics Data System (ADS)
Nishimura, K.; Dey, B.; Aston, D.; Leith, D. W. G. S.; Ratcliff, B.; Roberts, D.; Ruckman, L.; Shtol, D.; Varner, G. S.; Va'vra, J.
2013-02-01
We present a detailed study of a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC) with waveform digitizing electronics. In this study, the FDIRC prototype has been instrumented with seven Hamamatsu H-8500 MaPMTs. Waveforms from 384 pixels are digitized with waveform sampling electronics based on the BLAB2 ASIC, operating at a sampling speed of ∼2.5 GSa/s. The FDIRC prototype was tested in a large cosmic ray telescope (CRT) providing 3D muon tracks with ∼1.5 mrad angular resolution and muon energy of Emuon> 1.6 GeV. In this study we provide a detailed analysis of the tails in the Cherenkov angle distribution as a function of various variables, compare experimental results with simulation, and identify the major contributions to the tails. We demonstrate that to see the full impact of these tails on the Cherenkov angle resolution, it is crucial to use 3D tracks, and have a full understanding of the role of reconstruction ambiguities. These issues could not be fully explored in previous FDIRC studies where the beam was perpendicular to the quartz radiator bars. This work is relevant for the final FDIRC prototype of the PID detector at SuperB, which will be tested this year in the CRT setup.
Nollen, Nicole L.; Hutcheson, Tresza; Carlson, Susan; Rapoff, Michael; Goggin, Kathy; Mayfield, Carlene; Ellerbeck, Edward
2013-01-01
Mobile technologies hold promise for improving diet and physical activity, but little attention is given to creating programs that adolescents like and will use. This study developed a personal digital assistant (PDA) program to promote increased intake of fruits and vegetables (FV) in predominately low-income, ethnic minority girls. This study used a three-phase community-engaged process, including (i) engagement of a Student Advisory Board (SAB) to determine comfort with PDAs; (ii) early testing of Prototype I and rapid re-design by the SAB and (iii) feasibility testing of Prototype II in a new sample of girls. Phase 1 results showed that girls were comfortable with the PDA. Testing of Prototype I in Phase 2 showed that acceptability was mixed, with girls responding to 47.3% of the prompts. Girls wanted more reminders, accountability in monitoring FV, help in meeting daily goals and free music downloads based on program use. The PDA was reprogrammed and testing of Prototype II in Phase 3 demonstrated marked improvement in use (78.3%), increases in FV intake (1.8 ± 2.6 daily servings) and good overall satisfaction. Findings suggest that mobile technology designed with the early input of youth is a promising way to improve adolescent health behaviors. PMID:22949499
Integrating Rapid Prototyping into Graphic Communications
ERIC Educational Resources Information Center
Xu, Renmei; Flowers, Jim
2015-01-01
Integrating different science, technology, engineering, and mathematics (STEM) areas can help students learn and leverage both the equipment and expertise at a single school. In comparing graphic communications classes with classes that involve rapid prototyping (RP) technologies like 3D printing, there are sufficient similarities between goals,…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frazier, Christopher Rawls; Durfee, Justin David; Bandlow, Alisa
The Contingency Contractor Optimization Tool – Prototype (CCOT-P) database is used to store input and output data for the linear program model described in [1]. The database allows queries to retrieve this data and updating and inserting new input data.
Development of a tele-stethoscope and its application in pediatric cardiology.
Hedayioglu, F L; Mattos, S S; Moser, L; de Lima, M E
2007-01-01
Over the years, many attempts have been made to develop special stethoscopes for the teaching of auscultation. The objective of this article is to report on the experience with the development and implementation of an electronic stethoscope and a virtual library of cardiac sounds. There were four stages to this project: (1) the building of the prototype to acquire, filter and amplify the cardiac sounds, (2) the development of a software program to record, reproduce and visualize them, (3) the testing of the prototype in a clinical scenario, and (4) the development of an internet site, to store and display the sounds collected. The first two stages are now complete. The prototype underwent an initial evaluation in a clinical scenario within the Unit and during virtual out-patient clinical sessions. One hundred auscultations were recorded during these tests. They were reviewed and discussed on-line by a panel of experience cardiologists during the sessions. Although the sounds were considered "satisfactory" for diagnostic purposes by the cardiology team, they identified some qualitative differences in the electronic recorded auscultations, such as a higher pitch of the recorded sounds. Prospective clinical studies are now being conducted to further evaluate the interference of the electronic device in the physicians' capability to diagnose different cardiac conditions. An internet site (www.caduceusvirtual.com.br/ auscultaped) was developed to host these cardiac auscultations. It is set as a library of cardiac sounds, catalogued by pathologies and already contains examples from auscultations of the majority of common congenital heart lesions, such as septal defects and valvar lesions.
The 3D scanner prototype utilize object profile imaging using line laser and octave software
NASA Astrophysics Data System (ADS)
Nurdini, Mugi; Manunggal, Trikarsa Tirtadwipa; Samsi, Agus
2016-11-01
Three-dimensional scanner or 3D Scanner is a device to reconstruct the real object into digital form on a computer. 3D Scanner is a technology that is being developed, especially in developed countries, where the current 3D Scanner devices is the advanced version with a very expensive prices. This study is basically a simple prototype of 3D Scanner with a very low investment costs. 3D Scanner prototype device consists of a webcam, a rotating desk system controlled by a stepper motor and Arduino UNO, and a line laser. Objects that limit the research is the object with same radius from its center point (object pivot). Scanning is performed by using object profile imaging by line laser which is then captured by the camera and processed by a computer (image processing) using Octave software. On each image acquisition, the scanned object on a rotating desk rotated by a certain degree, so for one full turn multiple images of a number of existing side are finally obtained. Then, the profile of the entire images is extracted in order to obtain digital object dimension. Digital dimension is calibrated by length standard, called gage block. Overall dimensions are then digitally reconstructed into a three-dimensional object. Validation of the scanned object reconstruction of the original object dimensions expressed as a percentage error. Based on the results of data validation, horizontal dimension error is about 5% to 23% and vertical dimension error is about +/- 3%.
I3Mote: An Open Development Platform for the Intelligent Industrial Internet
Martinez, Borja; Vilajosana, Xavier; Kim, Il Han; Zhou, Jianwei; Tuset-Peiró, Pere; Xhafa, Ariton; Poissonnier, Dominique; Lu, Xiaolin
2017-01-01
In this article we present the Intelligent Industrial Internet (I3) Mote, an open hardware platform targeting industrial connectivity and sensing deployments. The I3Mote features the most advanced low-power components to tackle sensing, on-board computing and wireless/wired connectivity for demanding industrial applications. The platform has been designed to fill the gap in the industrial prototyping and early deployment market with a compact form factor, low-cost and robust industrial design. I3Mote is an advanced and compact prototyping system integrating the required components to be deployed as a product, leveraging the need for adopting industries to build their own tailored solution. This article describes the platform design, firmware and software ecosystem and characterizes its performance in terms of energy consumption. PMID:28452945
The prototype detection unit of the KM3NeT detector
NASA Astrophysics Data System (ADS)
Adrián-Martínez, S.; Ageron, M.; Aharonian, F.; Aiello, S.; Albert, A.; Ameli, F.; Anassontzis, E. G.; Androulakis, G. C.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardid, M.; Avgitas, T.; Balasi, K.; Band, H.; Barbarino, G.; Barbarito, E.; Barbato, F.; Baret, B.; Baron, S.; Barrios, J.; Belias, A.; Berbee, E.; van den Berg, A. M.; Berkien, A.; Bertin, V.; Beurthey, S.; van Beveren, V.; Beverini, N.; Biagi, S.; Biagioni, A.; Bianucci, S.; Billault, M.; Birbas, A.; Boer Rookhuizen, H.; Bormuth, R.; Bouché, V.; Bouhadef, B.; Bourlis, G.; Boutonnet, C.; Bouwhuis, M.; Bozza, C.; Bruijn, R.; Brunner, J.; Cacopardo, G.; Caillat, L.; Calamai, M.; Calvo, D.; Capone, A.; Caramete, L.; Caruso, F.; Cecchini, S.; Ceres, A.; Cereseto, R.; Champion, C.; Château, F.; Chiarusi, T.; Christopoulou, B.; Circella, M.; Classen, L.; Cocimano, R.; Coleiro, A.; Colonges, S.; Coniglione, R.; Cosquer, A.; Costa, M.; Coyle, P.; Creusot, A.; Cuttone, G.; D'Amato, C.; D'Amico, A.; De Bonis, G.; De Rosa, G.; Deniskina, N.; Destelle, J.-J.; Distefano, C.; Di Capua, F.; Donzaud, C.; Dornic, D.; Dorosti-Hasankiadeh, Q.; Drakopoulou, E.; Drouhin, D.; Drury, L.; Durand, D.; Eberl, T.; Elsaesser, D.; Enzenhöfer, A.; Fermani, P.; Fusco, L. A.; Gajanana, D.; Gal, T.; Galatà, S.; Garufi, F.; Gebyehu, M.; Giordano, V.; Gizani, N.; Gracia Ruiz, R.; Graf, K.; Grasso, R.; Grella, G.; Grmek, A.; Habel, R.; van Haren, H.; Heid, T.; Heijboer, A.; Heine, E.; Henry, S.; Hernández-Rey, J. J.; Herold, B.; Hevinga, M. A.; van der Hoek, M.; Hofestädt, J.; Hogenbirk, J.; Hugon, C.; Hößl, J.; Imbesi, M.; James, C. W.; Jansweijer, P.; Jochum, J.; de Jong, M.; Jongen, M.; Kadler, M.; Kalekin, O.; Kappes, A.; Kappos, E.; Katz, U.; Kavatsyuk, O.; Keller, P.; Kieft, G.; Koffeman, E.; Kok, H.; Kooijman, P.; Koopstra, J.; Korporaal, A.; Kouchner, A.; Kreykenbohm, I.; Kulikovskiy, V.; Lahmann, R.; Lamare, P.; Larosa, G.; Lattuada, D.; Le Provost, H.; Leismüller, K. P.; Leisos, A.; Lenis, D.; Leonora, E.; Lindsey Clark, M.; Llorens Alvarez, C. D.; Löhner, H.; Lonardo, A.; Loucatos, S.; Louis, F.; Maccioni, E.; Mannheim, K.; Manolopoulos, K.; Margiotta, A.; Mariş, O.; Markou, C.; Martínez-Mora, J. A.; Martini, A.; Masullo, R.; Melis, K. W.; Michael, T.; Migliozzi, P.; Migneco, E.; Miraglia, A.; Mollo, C. M.; Mongelli, M.; Morganti, M.; Mos, S.; Moudden, Y.; Musico, P.; Musumeci, M.; Nicolaou, C.; Nicolau, C. A.; Orlando, A.; Orzelli, A.; Papaikonomou, A.; Papaleo, R.; Păvălaş, G. E.; Peek, H.; Pellegrino, C.; Pellegriti, M. G.; Perrina, C.; Piattelli, P.; Pikounis, K.; Popa, V.; Pradier, Th.; Priede, M.; Pühlhofer, G.; Pulvirenti, S.; Racca, C.; Raffaelli, F.; Randazzo, N.; Rapidis, P. A.; Razis, P.; Real, D.; Resvanis, L.; Reubelt, J.; Riccobene, G.; Rovelli, A.; Saldaña, M.; Samtleben, D. F. E.; Sanguineti, M.; Santangelo, A.; Sapienza, P.; Schmelling, J.; Schnabel, J.; Sciacca, V.; Sedita, M.; Seitz, T.; Sgura, I.; Simeone, F.; Sipala, V.; Spitaleri, A.; Spurio, M.; Stavropoulos, G.; Steijger, J.; Stolarczyk, T.; Stransky, D.; Taiuti, M.; Terreni, G.; Tézier, D.; Théraube, S.; Thompson, L. F.; Timmer, P.; Trasatti, L.; Trovato, A.; Tselengidou, M.; Tsirigotis, A.; Tzamarias, S.; Tzamariudaki, E.; Vallage, B.; Van Elewyck, V.; Vermeulen, J.; Vernin, P.; Vicini, P.; Viola, S.; Vivolo, D.; Werneke, P.; Wiggers, L.; Wilms, J.; de Wolf, E.; van Wooning, R. H. L.; Zonca, E.; Zornoza, J. D.; Zúñiga, J.; Zwart, A.
2016-02-01
A prototype detection unit of the KM3NeT deep-sea neutrino telescope has been installed at 3500m depth 80 km offshore the Italian coast. KM3NeT in its final configuration will contain several hundreds of detection units. Each detection unit is a mechanical structure anchored to the sea floor, held vertical by a submerged buoy and supporting optical modules for the detection of Cherenkov light emitted by charged secondary particles emerging from neutrino interactions. This prototype string implements three optical modules with 31 photomultiplier tubes each. These optical modules were developed by the KM3NeT Collaboration to enhance the detection capability of neutrino interactions. The prototype detection unit was operated since its deployment in May 2014 until its decommissioning in July 2015. Reconstruction of the particle trajectories from the data requires a nanosecond accuracy in the time calibration. A procedure for relative time calibration of the photomultiplier tubes contained in each optical module is described. This procedure is based on the measured coincidences produced in the sea by the ^{40}K background light and can easily be expanded to a detector with several thousands of optical modules. The time offsets between the different optical modules are obtained using LED nanobeacons mounted inside them. A set of data corresponding to 600 h of livetime was analysed. The results show good agreement with Monte Carlo simulations of the expected optical background and the signal from atmospheric muons. An almost background-free sample of muons was selected by filtering the time correlated signals on all the three optical modules. The zenith angle of the selected muons was reconstructed with a precision of about 3°.
A Graphics Environment Supporting the Rapid Prototyping of Pictorial Cockpit Displays
1986-12-01
0 - niDi cO 3 FIL .OF I A GRAPHICS ENVIRONMENT SUPPORTING THE RAPID PROTOTYPING OF PICTORIAL COCKPIT DISPLAYS THESIS Alan J. Braaten Captain, USAF...COCKPIT DISPLAYS THESIS Alan J. Braaten Captain, USAF AFIT/GCS/IA/86D- 1 Appram:ed for public release; distribution unlimited AFIT/GCS/MA/80- 1 A...GRAPHICS ENVIROWNT SUPPORTING THE RAPID PROTOTYPING OF PICTORIAL COCKPIT DISPLAYS THESIS Preented to the Faculty Of the School of Engineering of the Air
An Evaluation of the Argentinean Basic Trainer Aircraft Domestic Development Project
2012-03-01
Prototype, 1st jet built in Latin America 1947 IAe 31 Colibrí Two- seat Trainer aircraft 3 National design 1948 IAe 30 Ñancú Fighter/Attack prototype...37 Supersonic delta-wing interceptor (Glider, unpowered prototype only) 1 Designed by Reimar Horten. 1957 IAe 46 Ranquel 2- seat utility...return all surfaces to neutral. It must be operable from both positions, with priority on the rear command seat . • Ergonomic Throttle controls on the
Development of a 3D CZT detector prototype for Laue Lens telescope
NASA Astrophysics Data System (ADS)
Caroli, Ezio; Auricchio, Natalia; Del Sordo, Stefano; Abbene, Leonardo; Budtz-Jørgensen, Carl; Casini, Fabio; Curado da Silva, Rui M.; Kuvvetlli, Irfan; Milano, Luciano; Natalucci, Lorenzo; Quadrini, Egidio M.; Stephen, John B.; Ubertini, Pietro; Zanichelli, Massimiliano; Zappettini, Andrea
2010-07-01
We report on the development of a 3D position sensitive prototype suitable as focal plane detector for Laue lens telescope. The basic sensitive unit is a drift strip detector based on a CZT crystal, (~19×8 mm2 area, 2.4 mm thick), irradiated transversally to the electric field direction. The anode side is segmented in 64 strips, that divide the crystal in 8 independent sensor (pixel), each composed by one collecting strip and 7 (one in common) adjacent drift strips. The drift strips are biased by a voltage divider, whereas the anode strips are held at ground. Furthermore, the cathode is divided in 4 horizontal strips for the reconstruction of the third interaction position coordinate. The 3D prototype will be made by packing 8 linear modules, each composed by one basic sensitive unit, bonded on a ceramic layer. The linear modules readout is provided by a custom front end electronics implementing a set of three RENA-3 for a total of 128 channels. The front-end electronics and the operating logics (in particular coincidence logics for polarisation measurements) are handled by a versatile and modular multi-parametric back end electronics developed using FPGA technology.
Test of the CLAS12 RICH large-scale prototype in the direct proximity focusing configuration
Anefalos Pereira, S.; Baltzell, N.; Barion, L.; ...
2016-02-11
A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c up to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Laboratory. The adopted solution foresees a novel hybrid optics design based on aerogel radiator, composite mirrors and high-packed and high-segmented photon detectors. Cherenkov light will either be imaged directly (forward tracks) or after two mirror reflections (large angle tracks). We report here the results of the tests of a large scale prototype of the RICH detector performed withmore » the hadron beam of the CERN T9 experimental hall for the direct detection configuration. As a result, the tests demonstrated that the proposed design provides the required pion-to-kaon rejection factor of 1:500 in the whole momentum range.« less
Cool-Down and Current Test Results of the KSTAR Prototype TF Coil
NASA Astrophysics Data System (ADS)
Oh, Y. K.; Lee, S.; Chu, Y.; Park, K. R.; Yonekawa, H.; Baek, S. H.; Cho, K. W.; Park, Y. M.; Kim, M. K.; Chang, H. S.; Kim, Y. S.; Chang, Y. B.; Lee, Y. J.; Kim, W. C.; Kim, K.; Kwag, S. W.; Lee, S. H.; Yang, S. H.; Lee, S. J.; Bak, J. S.; Lee, G. S.
2004-06-01
A prototype toroidal field (TF) coil, TF00 coil, of the Korea Superconducting Tokamak Advanced Research (KSTAR) project has been assembled and tested at the coil test facility in Korea Basic Science Institute (KBSI). The TF00 coil is a real-sized TF coil made of Nb3Sn superconducting cable-in-conduit conductor (CICC). The coil test was conducted by several campaigns according to the objectives. The first campaign, which was carried out by Jan. 2003, has objectives of cooling the coil into operating temperature and finding any defect in the coil such as cold leaks. From the results of the first campaign experiment, any defect in the coil was not found. The second campaign, which was carried out by Aug. 2003, has objectives to get the operating characteristics according to the current ramp up and discharge operations. In this paper, the coil test results are introduced as well as the details of the coil test system setup.
NASA Astrophysics Data System (ADS)
Mojiri, Ahmad; Stanley, Cameron; Rosengarten, Gary
2015-09-01
Hybrid photovoltaic/thermal (PV-T) solar collectors are capable of delivering heat and electricity concurrently. Implementing such receivers in linear concentrators for high temperature applications need special considerations such as thermal decoupling of the photovoltaic (pv) cells from the thermal receiver. Spectral beam splitting of concentrated light provides an option for achieving this purpose. In this paper we introduce a relatively simple hybrid receiver configuration that spectrally splits the light between a high temperature thermal fluid and silicon pv cells using volumetric light filtering by semi-conductor doped glass and propylene glycol. We analysed the optical performance of this device theoretically using ray tracing and experimentally through the construction and testing of a full scale prototype. The receiver was mounted on a commercial parabolic trough concentrator in an outdoor experiment. The prototype receiver delivered heat and electricity at total thermal efficiency of 44% and electrical efficiency of 3.9% measured relative to the total beam energy incident on the primary mirror.
MAPS development for the ALICE ITS upgrade
NASA Astrophysics Data System (ADS)
Yang, P.; Aglieri, G.; Cavicchioli, C.; Chalmet, P. L.; Chanlek, N.; Collu, A.; Gao, C.; Hillemanns, H.; Junique, A.; Kofarago, M.; Keil, M.; Kugathasan, T.; Kim, D.; Kim, J.; Lattuca, A.; Marin Tobon, C. A.; Marras, D.; Mager, M.; Martinengo, P.; Mazza, G.; Mugnier, H.; Musa, L.; Puggioni, C.; Rousset, J.; Reidt, F.; Riedler, P.; Snoeys, W.; Siddhanta, S.; Usai, G.; van Hoorne, J. W.; Yi, J.
2015-03-01
Monolithic Active Pixel Sensors (MAPS) offer the possibility to build pixel detectors and tracking layers with high spatial resolution and low material budget in commercial CMOS processes. Significant progress has been made in the field of MAPS in recent years, and they are now considered for the upgrades of the LHC experiments. This contribution will focus on MAPS detectors developed for the ALICE Inner Tracking System (ITS) upgrade and manufactured in the TowerJazz 180 nm CMOS imaging sensor process on wafers with a high resistivity epitaxial layer. Several sensor chip prototypes have been developed and produced to optimise both charge collection and readout circuitry. The chips have been characterised using electrical measurements, radioactive sources and particle beams. The tests indicate that the sensors satisfy the ALICE requirements and first prototypes with the final size of 1.5 × 3 cm2 have been produced in the first half of 2014. This contribution summarises the characterisation measurements and presents first results from the full-scale chips.
Prototyping a Sensor Enabled 3d Citymodel on Geospatial Managed Objects
NASA Astrophysics Data System (ADS)
Kjems, E.; Kolář, J.
2013-09-01
One of the major development efforts within the GI Science domain are pointing at sensor based information and the usage of real time information coming from geographic referenced features in general. At the same time 3D City models are mostly justified as being objects for visualization purposes rather than constituting the foundation of a geographic data representation of the world. The combination of 3D city models and real time information based systems though can provide a whole new setup for data fusion within an urban environment and provide time critical information preserving our limited resources in the most sustainable way. Using 3D models with consistent object definitions give us the possibility to avoid troublesome abstractions of reality, and design even complex urban systems fusing information from various sources of data. These systems are difficult to design with the traditional software development approach based on major software packages and traditional data exchange. The data stream is varying from urban domain to urban domain and from system to system why it is almost impossible to design a complete system taking care of all thinkable instances now and in the future within one constraint software design complex. On several occasions we have been advocating for a new end advanced formulation of real world features using the concept of Geospatial Managed Objects (GMO). This paper presents the outcome of the InfraWorld project, a 4 million Euro project financed primarily by the Norwegian Research Council where the concept of GMO's have been applied in various situations on various running platforms of an urban system. The paper will be focusing on user experiences and interfaces rather then core technical and developmental issues. The project was primarily focusing on prototyping rather than realistic implementations although the results concerning applicability are quite clear.
The WEBD project: a research of new methodologies for a distant-learning 3D system prototype.
Cemenasco, A F; Bianchi, C C; Tornincasa, S; Bianchi, S D
2004-11-01
To create and to spread a new interactive multimedia instrument, based upon virtual reality technologies, that allows both the running simulation of machines and equipment and the reproduction via Web of complex three-dimensional (3D) anatomical models such as the skull. There were two main aspects of the project, one of design engineering and the other biomedical engineering, for the creation of "artificial" and anatomical objects. The former were made with 3D Studio Max R4 by Autodesk, San Rafael, CA, while the latter were created starting from real bones scanned with a CT system or a surface scanner and elaborated with different programs (3D Studio Max R4, Scenebuilder by Viewpoint, New York, NY and Spinfire by Actify, San Francisco, CA). The 3D models were to be integrated into web modules and had to respect file limits while preserving a sufficient definition. Two systems of evaluation were used, a questionnaire on a selected sample and an external evaluation by a different university. The Viewpoint format offers the best interactivity and size reduction (up to 96% from the original 3D model). The created modules included production of radiological images, rapid prototyping, and anatomy. The complete "3D Distant Learning Prototype" is available at www.webd.etsii.upm.es. The software currently available permits the construction of interactive modules. The verification on the selected sample and the evaluation by the University of Naples show that the structure is well organized and that the integration of the 3D models meets the requirements.
2017-09-08
Majid Babai along with Dr. Judy Schneider, and graduate students Chris Hill and Ryan Anderson examine a cross section of the prototype rocket engine igniter created by an innovative bi-metallic 3-D printing advanced manufacturing process under a microscope.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-04
... for research entitled ``Experimental Study of Patient Information Prototypes.'' This study is designed..., the working group refined several prototypes and designed a study to investigate the usefulness of... Design and Protocol The study is experimental and will have two independent variables in a 3 x 2 design...
"No Fun Games": Engagement Effects of Two Gameful Assessment Prototypes
ERIC Educational Resources Information Center
Guerreiro, Meg; Nordengren, Chase
2018-01-01
Assessments with features of games propose to address student motivation deficits common in traditional assessments. This study examines the impact of two "gameful assessment" prototypes on student engagement and teacher perceptions among 391 Grades 3-7 students and 14 teachers in one Midwestern and one Northwestern school. Using mixed…
Localization of a mobile laser scanner via dimensional reduction
NASA Astrophysics Data System (ADS)
Lehtola, Ville V.; Virtanen, Juho-Pekka; Vaaja, Matti T.; Hyyppä, Hannu; Nüchter, Andreas
2016-11-01
We extend the concept of intrinsic localization from a theoretical one-dimensional (1D) solution onto a 2D manifold that is embedded in a 3D space, and then recover the full six degrees of freedom for a mobile laser scanner with a simultaneous localization and mapping algorithm (SLAM). By intrinsic localization, we mean that no reference coordinate system, such as global navigation satellite system (GNSS), nor inertial measurement unit (IMU) are used. Experiments are conducted with a 2D laser scanner mounted on a rolling prototype platform, VILMA. The concept offers potential in being extendable to other wheeled platforms.
The space shuttle payload planning working groups. Volume 7: Earth observations
NASA Technical Reports Server (NTRS)
1973-01-01
The findings of the Earth Observations working group of the space shuttle payload planning activity are presented. The objectives of the Earth Observation experiments are: (1) establishment of quantitative relationships between observable parameters and geophysical variables, (2) development, test, calibration, and evaluation of eventual flight instruments in experimental space flight missions, (3) demonstration of the operational utility of specific observation concepts or techniques as information inputs needed for taking actions, and (4) deployment of prototype and follow-on operational Earth Observation systems. The basic payload capability, mission duration, launch sites, inclinations, and payload limitations are defined.
High Temperature Ultrasonic Transducer for Real-time Inspection
NASA Astrophysics Data System (ADS)
Amini, Mohammad Hossein; Sinclair, Anthony N.; Coyle, Thomas W.
A broadband ultrasonic transducer with a novel porous ceramic backing layer is introduced to operate at 700 °C. 36° Y-cut lithium niobate (LiNbO3) single crystal was selected for the piezoelectric element. By appropriate choice of constituent materials, porosity and pore size, the acoustic impedance and attenuation of a zirconia-based backing layer were optimized. An active brazing alloy with high temperature and chemical stability was selected to bond the transducer layers together. Prototype transducers have been tested at temperatures up to 700 °C. The experiments confirmed that transducer integrity was maintained.
Development of an interprofessional competency framework for collaborative practice in Japan.
Haruta, Junji; Yoshida, Kazue; Goto, Michiko; Yoshimoto, Hisashi; Ichikawa, Shuhei; Mori, Youhei; Yoshimi, Kenji; Otsuka, Mariko
2018-01-30
Rapid aging of the population necessitates improved collaboration among healthcare professionals. Unfortunately, interprofessional collaboration has yet to be implemented effectively in Japan. Therefore, we aimed to develop an interprofessional competency framework for Japanese healthcare professionals. The project was conducted as a four-step process, starting with initial categorization of potential competency domains,, followed by guiding principle and prototype development, feedback on the prototype, and final consensus. First, authors (JH and MO) collected opinions about competency in interprofessional collaboration at two academic meetings of the Japan Association for Interprofessional Education (JAIPE) and then analyzed the data thematically. Second, a project team consisting of JAIPE and University representatives extracted the domains and statements as prototype 1. Third, seven representatives from professional organizations joined the project team and developed prototype 2. We then called for feedback on the revised prototype 2 at both an open symposium and via public comments. Following revision of prototype 2, a new project team including 20 university, professional organization and health practitioner representatives finally discussed prototype 3, developed the final draft and reached a consensus. In analysis after collecting the data, we extracted 11 themes. We developed four key principles which applied to six domains as prototype 1-3. Finally, our competency framework included two core domains of "Patient-/client-/family-/community-centered" and "Interprofessional communication", and four peripheral domains of "Role contribution", "Facilitation of relationships", "Reflection" and "Understanding of others". We developed an interprofessional competency framework in Japan which consists of two core and four peripheral domains. The interprofessional competency framework is likely to affect the understanding of "high-context" and "relationalism" in Japanese healthcare. We hope that our interprofessional competency framework will encourage the systematic implementation of interprofessional education and collaboration in Japan.
Nelson, Scott D; Del Fiol, Guilherme; Hanseler, Haley; Crouch, Barbara Insley; Cummins, Mollie R
2016-01-01
Health information exchange (HIE) between Poison Control Centers (PCCs) and Emergency Departments (EDs) could improve care of poisoned patients. However, PCC information systems are not designed to facilitate HIE with EDs; therefore, we are developing specialized software to support HIE within the normal workflow of the PCC using user-centered design and rapid prototyping. To describe the design of an HIE dashboard and the refinement of user requirements through rapid prototyping. Using previously elicited user requirements, we designed low-fidelity sketches of designs on paper with iterative refinement. Next, we designed an interactive high-fidelity prototype and conducted scenario-based usability tests with end users. Users were asked to think aloud while accomplishing tasks related to a case vignette. After testing, the users provided feedback and evaluated the prototype using the System Usability Scale (SUS). Survey results from three users provided useful feedback that was then incorporated into the design. After achieving a stable design, we used the prototype itself as the specification for development of the actual software. Benefits of prototyping included having 1) subject-matter experts heavily involved with the design; 2) flexibility to make rapid changes, 3) the ability to minimize software development efforts early in the design stage; 4) rapid finalization of requirements; 5) early visualization of designs; 6) and a powerful vehicle for communication of the design to the programmers. Challenges included 1) time and effort to develop the prototypes and case scenarios; 2) no simulation of system performance; 3) not having all proposed functionality available in the final product; and 4) missing needed data elements in the PCC information system.
Synergic effects of ultrasound and laser on the pain relief in women with hand osteoarthritis.
Paolillo, Alessandra Rossi; Paolillo, Fernanda Rossi; João, Jessica Patrícia; João, Herbert Alexandre; Bagnato, Vanderlei Salvador
2015-01-01
Patients with pain avoid movements, leading to a gradual impairment of their physical condition and functionality. In this context, the use of ultrasound (US) and low-level laser therapy (LLLT) show promising results for nonpharmacological and noninvasive treatment. The aim of this study was evaluated the synergistic effects of the US and the LLLT (new prototype) with or without therapeutic exercises (TE) on pain and grip strength in women with hand osteoarthritis. Forty-five women with hand osteoarthritis, aged 60 to 80 years, were randomly assigned to one of three groups, but 43 women successfully completed the full study. The three groups were as follows: (i) the placebo group which did not perform TE, but the prototype without emitting electromagnetic or mechanical waves was applied (n = 11); (ii) the US + LLLT group which carried out only the prototype (n = 13); and (iii) the TE + US + LLLT group which performed TE before the prototype is applied (n = 13). The parameters of US were frequency 1 MHz; 1.0 W/cm(2) intensity, pulsed mode 1:1 (duty cycle 50%). Regarding laser, the output power of the each laser was fixed at 100 mW leading to an energy value of 18 J per laser. Five points were irradiated per hand, during 3 min per point and 15 min per session. The prototype was applied after therapeutic exercises. The treatments are done once a week for 3 months. Grip strength and pressure pain thresholds (PPT) were measured. Grip strength did not differ significantly for any of the groups (p ≥ 0.05). The average PPT between baseline and 3 months shows significant decrease of the pain sensitivity for both the US + LLLT group (∆ = 30 ± 19 N, p˂0.001) and the TE + US + LLLT group (∆ = 32 ± 13 N, p < 0.001). However, there were no significant differences in average PPT for placebo group (∆ = -0.3 ± 9 N). There was no placebo effect. The new prototype that combines US and LLLT reduced pain in women with hand osteoarthritis.
Utilization survey of prototype structural test article
NASA Technical Reports Server (NTRS)
Baber, S.; Mcdaniel, H. M.; Berry, M. J.
1974-01-01
A survey was conducted of six aerospace companies and two NASA agencies to determine how prototype structural test articles are used in flight operations. The prototype structures are airframes and similar devices which are used for testing and generally are not flown. The survey indicated the following: (1) prototype test articles are not being discarded after development testing is complete, but are used for other purposes, (2) only two cases of prototypes being refurbished and flown were identified, (3) protective devices and inspection techniques are available to prevent or minimize test article damage, (4) substitute programs from design verification are availabel in lieu of using prototype structural articles, and (5) there is a trend away from dedicated test articles. Four options based on these study results were identified to reduce test and hardware costs without compromising reliability of the flight program.
Cost analysis of life support systems
NASA Technical Reports Server (NTRS)
Yakut, M. M.
1973-01-01
A methodology was developed to predict realistic relative cost of Life Support Systems (LSS) and to define areas of major cost impacts in the development cycle. Emphasis was given to tailoring the cost data for usage by program planners and designers. The equipment classifications used based on the degree of refinement were as follows: (1) Working model; (2) low-fidelity prototype; (3) high-fidelity prototype; and (4) flight-qualified system. The major advanced LSS evaluated included the following: (1) Carbon dioxide removal; (2) oxygen recovery systems; (3) water recovery systems; (4) atmosphere analysis system.
Development and parametric evaluation of the prototype 2 and 3 flash evaporators
NASA Technical Reports Server (NTRS)
Hixon, C. W.; Dietz, J. B.
1975-01-01
Development of the Prototype 2 and 3 flash evaporator heat sinks which vaporize an expendable fluid to cool a heat transport fluid loop is reported. The units utilize Freon 21 as the heat transport fluid and water as the expendable fluid to meet the projected performance requirements of the space shuttle for both on-orbit and ascent/reentry operations. The evaporant is pulse-sprayed by on-off control onto heat transfer surfaces containing the transport fluid and exhausted to the vacuum environment through fixed area exhaust ducts.
Recent development on computer aided tissue engineering--a review.
Sun, Wei; Lal, Pallavi
2002-02-01
The utilization of computer-aided technologies in tissue engineering has evolved in the development of a new field of computer-aided tissue engineering (CATE). This article reviews recent development and application of enabling computer technology, imaging technology, computer-aided design and computer-aided manufacturing (CAD and CAM), and rapid prototyping (RP) technology in tissue engineering, particularly, in computer-aided tissue anatomical modeling, three-dimensional (3-D) anatomy visualization and 3-D reconstruction, CAD-based anatomical modeling, computer-aided tissue classification, computer-aided tissue implantation and prototype modeling assisted surgical planning and reconstruction.
Manufacturing technology methodology for propulsion system parts
NASA Astrophysics Data System (ADS)
McRae, M. M.
1992-07-01
A development history and a current status evaluation are presented for lost-wax casting of such gas turbine engine components as turbine vanes and blades. The most advanced such systems employ computer-integrated manufacturing methods for high process repeatability, reprogramming versatility, and feedback monitoring. Stereolithography-based plastic model 3D prototyping has also been incorporated for the wax part of the investment casting; it may ultimately be possible to produce the 3D prototype in wax directly, or even to create a ceramic mold directly. Nonintrusive inspections are conducted by X-radiography and neutron radiography.
Prototype diagnosis of psychiatric syndromes
WESTEN, DREW
2012-01-01
The method of diagnosing patients used since the early 1980s in psychiatry, which involves evaluating each of several hundred symptoms for their presence or absence and then applying idiosyncratic rules for combining them for each of several hundred disorders, has led to great advances in research over the last 30 years. However, its problems have become increasingly apparent, particularly for clinical practice. An alternative approach, designed to maximize clinical utility, is prototype matching. Instead of counting symptoms of a disorder and determining whether they cross an arbitrary cutoff, the task of the diagnostician is to gauge the extent to which a patient’s clinical presentation matches a paragraph-length description of the disorder using a simple 5-point scale, from 1 (“little or no match”) to 5 (“very good match”). The result is both a dimensional diagnosis that captures the extent to which the patient “has” the disorder and a categorical diagnosis, with ratings of 4 and 5 corresponding to presence of the disorder and a rating of 3 indicating “subthreshold” or “clinically significant features”. The disorders and criteria woven into the prototypes can be identified empirically, so that the prototypes are both scientifically grounded and clinically useful. Prototype diagnosis has a number of advantages: it better captures the way humans naturally classify novel and complex stimuli; is clinically helpful, reliable, and easy to use in everyday practice; facilitates both dimensional and categorical diagnosis and dramatically reduces the number of categories required for classification; allows for clinically richer, empirically derived, and culturally relevant classification; reduces the gap between research criteria and clinical knowledge, by allowing clinicians in training to learn a small set of standardized prototypes and to develop richer mental representations of the disorders over time through clinical experience; and can help resolve the thorny issue of the relation between psychiatric diagnosis and functional impairment. PMID:22294998
Three-dimensional digitizer for the footwear industry
NASA Astrophysics Data System (ADS)
Gonzalez, Francisco; Campoy, Pascual; Aracil, Rafael; Penafiel, Francisco; Sebastian, Jose M.
1993-12-01
This paper presents a developed system for digitizing 3D objects in the footwear industry (e.g. mould, soles, heels) and their introduction in a CAD system for further manipulation and production of rapid prototypes. The system is based on the acquisition of the sequence of images of the projection of a laser line onto the 3D object when this is moving in front of the laser beam and the camera. This beam projection lights a 3D curve on the surface of the object, whose image is processed in order to obtain the 3D coordinates of every point of mentioned curve according to a previous calibration of the system. These coordinates of points in all the curves are analyzed and combined in order to make up a 3D wire-frame model of the object, which is introduced in a CAD station for further design and connection to the machinery for rapid prototyping.
Single Day Construction of Multigene Circuits with 3G Assembly.
Halleran, Andrew D; Swaminathan, Anandh; Murray, Richard M
2018-05-18
The ability to rapidly design, build, and test prototypes is of key importance to every engineering discipline. DNA assembly often serves as a rate limiting step of the prototyping cycle for synthetic biology. Recently developed DNA assembly methods such as isothermal assembly and type IIS restriction enzyme systems take different approaches to accelerate DNA construction. We introduce a hybrid method, Golden Gate-Gibson (3G), that takes advantage of modular part libraries introduced by type IIS restriction enzyme systems and isothermal assembly's ability to build large DNA constructs in single pot reactions. Our method is highly efficient and rapid, facilitating construction of entire multigene circuits in a single day. Additionally, 3G allows generation of variant libraries enabling efficient screening of different possible circuit constructions. We characterize the efficiency and accuracy of 3G assembly for various construct sizes, and demonstrate 3G by characterizing variants of an inducible cell-lysis circuit.
PERTS: A Prototyping Environment for Real-Time Systems
NASA Technical Reports Server (NTRS)
Liu, Jane W. S.; Lin, Kwei-Jay; Liu, C. L.
1991-01-01
We discuss an ongoing project to build a Prototyping Environment for Real-Time Systems, called PERTS. PERTS is a unique prototyping environment in that it has (1) tools and performance models for the analysis and evaluation of real-time prototype systems, (2) building blocks for flexible real-time programs and the support system software, (3) basic building blocks of distributed and intelligent real time applications, and (4) an execution environment. PERTS will make the recent and future theoretical advances in real-time system design and engineering readily usable to practitioners. In particular, it will provide an environment for the use and evaluation of new design approaches, for experimentation with alternative system building blocks and for the analysis and performance profiling of prototype real-time systems.
3D fingerprint imaging system based on full-field fringe projection profilometry
NASA Astrophysics Data System (ADS)
Huang, Shujun; Zhang, Zonghua; Zhao, Yan; Dai, Jie; Chen, Chao; Xu, Yongjia; Zhang, E.; Xie, Lili
2014-01-01
As an unique, unchangeable and easily acquired biometrics, fingerprint has been widely studied in academics and applied in many fields over the years. The traditional fingerprint recognition methods are based on the obtained 2D feature of fingerprint. However, fingerprint is a 3D biological characteristic. The mapping from 3D to 2D loses 1D information and causes nonlinear distortion of the captured fingerprint. Therefore, it is becoming more and more important to obtain 3D fingerprint information for recognition. In this paper, a novel 3D fingerprint imaging system is presented based on fringe projection technique to obtain 3D features and the corresponding color texture information. A series of color sinusoidal fringe patterns with optimum three-fringe numbers are projected onto a finger surface. From another viewpoint, the fringe patterns are deformed by the finger surface and captured by a CCD camera. 3D shape data of the finger can be obtained from the captured fringe pattern images. This paper studies the prototype of the 3D fingerprint imaging system, including principle of 3D fingerprint acquisition, hardware design of the 3D imaging system, 3D calibration of the system, and software development. Some experiments are carried out by acquiring several 3D fingerprint data. The experimental results demonstrate the feasibility of the proposed 3D fingerprint imaging system.
NASA Astrophysics Data System (ADS)
Chambion, Bertrand; Gaschet, Christophe; Behaghel, Thibault; Vandeneynde, Aurélie; Caplet, Stéphane; Gétin, Stéphane; Henry, David; Hugot, Emmanuel; Jahn, Wilfried; Lombardo, Simona; Ferrari, Marc
2018-02-01
Over the recent years, a huge interest has grown for curved electronics, particularly for opto-electronics systems. Curved sensors help the correction of off-axis aberrations, such as Petzval Field Curvature, astigmatism, and bring significant optical and size benefits for imaging systems. In this paper, we first describe advantages of curved sensor and associated packaging process applied on a 1/1.8'' format 1.3Mpx global shutter CMOS sensor (Teledyne EV76C560) into its standard ceramic package with a spherical radius of curvature Rc=65mm and 55mm. The mechanical limits of the die are discussed (Finite Element Modelling and experimental), and electro-optical performances are investigated. Then, based on the monocentric optical architecture, we proposed a new design, compact and with a high resolution, developed specifically for a curved image sensor including optical optimization, tolerances, assembly and optical tests. Finally, a functional prototype is presented through a benchmark approach and compared to an existing standard optical system with same performances and a x2.5 reduction of length. The finality of this work was a functional prototype demonstration on the CEA-LETI during Photonics West 2018 conference. All these experiments and optical results demonstrate the feasibility and high performances of systems with curved sensors.
Environmentally Benign Battlefield Effects Black Smoke Simulator
2006-11-01
tested and results Fuel Oxidizer Color of Smoke Density of Smoke Sugar (Sucrose) KNO3 Grey Medium Dextrin KNO3 Grey Thin Microcrystalline...design. 3.5 Initial Prototype Scale Fiberboard Testing Several quality black smoke formulations were identified in the small pellet testing to
Hirschberg, Cosima; Boetker, Johan P; Rantanen, Jukka; Pein-Hackelbusch, Miriam
2018-02-01
There is an increasing need to provide more detailed insight into the behavior of particulate systems. The current powder characterization tools are developed empirically and in many cases, modification of existing equipment is difficult. More flexible tools are needed to provide understanding of complex powder behavior, such as mixing process and segregation phenomenon. An approach based on the fast prototyping of new powder handling geometries and interfacing solutions for process analytical tools is reported. This study utilized 3D printing for rapid prototyping of customized geometries; overall goal was to assess mixing process of powder blends at small-scale with a combination of spectroscopic and mechanical monitoring. As part of the segregation evaluation studies, the flowability of three different paracetamol/filler-blends at different ratios was investigated, inter alia to define the percolation thresholds. Blends with a paracetamol wt% above the percolation threshold were subsequently investigated in relation to their segregation behavior. Rapid prototyping using 3D printing allowed designing two funnels with tailored flow behavior (funnel flow) of model formulations, which could be monitored with an in-line near-infrared (NIR) spectrometer. Calculating the root mean square (RMS) of the scores of the two first principal components of the NIR spectra visualized spectral variation as a function of process time. In a same setup, mechanical properties (basic flow energy) of the powder blend were monitored during blending. Rapid prototyping allowed for fast modification of powder testing geometries and easy interfacing with process analytical tools, opening new possibilities for more detailed powder characterization.
NASA Technical Reports Server (NTRS)
Torres-Pomales, Wilfredo
2012-01-01
An experiment was conducted to characterize the effects of HIRF-induced upsets on a prototype onboard data network. The experiment was conducted at the NASA Langley Research Center s High Intensity Radiation Field Laboratory and used a generic distributed system prototyping platform to realize the data network. This report presents the results of the hardware susceptibility threshold characterization which examined the dependence of measured susceptibility on factors like the frequency and modulation of the radiation, layout of the physical nodes and position of the nodes in the test chamber. The report also includes lessons learned during the development and execution of the experiment.
NASA Astrophysics Data System (ADS)
Gomez, R.; Gentle, J.
2015-12-01
Modern data pipelines and computational processes require that meticulous methodologies be applied in order to insure that the source data, algorithms, and results are properly curated, managed and retained while remaining discoverable, accessible, and reproducible. Given the complexity of understanding the scientific problem domain being researched, combined with the overhead of learning to use advanced computing technologies, it becomes paramount that the next generation of scientists and researchers learn to embrace best-practices. The Integrative Computational Education and Research Traineeship (ICERT) is a National Science Foundation (NSF) Research Experience for Undergraduates (REU) Site at the Texas Advanced Computing Center (TACC). During Summer 2015, two ICERT interns joined the 3DDY project. 3DDY converts geospatial datasets into file types that can take advantage of new formats, such as natural user interfaces, interactive visualization, and 3D printing. Mentored by TACC researchers for ten weeks, students with no previous background in computational science learned to use scripts to build the first prototype of the 3DDY application, and leveraged Wrangler, the newest high performance computing (HPC) resource at TACC. Test datasets for quadrangles in central Texas were used to assemble the 3DDY workflow and code. Test files were successfully converted into a stereo lithographic (STL) format, which is amenable for use with a 3D printers. Test files and the scripts were documented and shared using the Figshare site while metadata was documented for the 3DDY application using OntoSoft. These efforts validated a straightforward set of workflows to transform geospatial data and established the first prototype version of 3DDY. Adding the data and software management procedures helped students realize a broader set of tangible results (e.g. Figshare entries), better document their progress and the final state of their work for the research group and community, helped students and researchers follow a clear set of formats and fill in the necessary details that may be lost otherwise, and exposed the students to the next generation workflows and practices for digital scholarship and scientific inquiry for converting geospatial data into formats that are easy to reuse.
Studying the Elusive Experience in Pervasive Games
ERIC Educational Resources Information Center
Stenros, Jaakko; Waern, Annika; Montola, Markus
2012-01-01
Studying pervasive games is inherently difficult and different from studying computer or board games. This article builds upon the experiences of staging and studying several playful pervasive technology prototypes. It discusses the challenges and pitfalls of evaluating pervasive game prototypes and charts methods that have proven useful in…
Gas-phase advanced oxidation for effective, efficient in situ control of pollution.
Johnson, Matthew S; Nilsson, Elna J K; Svensson, Erik A; Langer, Sarka
2014-01-01
In this article, gas-phase advanced oxidation, a new method for pollution control building on the photo-oxidation and particle formation chemistry occurring in the atmosphere, is introduced and characterized. The process uses ozone and UV-C light to produce in situ radicals to oxidize pollution, generating particles that are removed by a filter; ozone is removed using a MnO2 honeycomb catalyst. This combination of in situ processes removes a wide range of pollutants with a comparatively low specific energy input. Two proof-of-concept devices were built to test and optimize the process. The laboratory prototype was built of standard ventilation duct and could treat up to 850 m(3)/h. A portable continuous-flow prototype built in an aluminum flight case was able to treat 46 m(3)/h. Removal efficiencies of >95% were observed for propane, cyclohexane, benzene, isoprene, aerosol particle mass, and ozone for concentrations in the range of 0.4-6 ppm and exposure times up to 0.5 min. The laboratory prototype generated a OH(•) concentration derived from propane reaction of (2.5 ± 0.3) × 10(10) cm(-3) at a specific energy input of 3 kJ/m(3), and the portable device generated (4.6 ± 0.4) × 10(9) cm(-3) at 10 kJ/m(3). Based on these results, in situ gas-phase advanced oxidation is a viable control strategy for most volatile organic compounds, specifically those with a OH(•) reaction rate higher than ca. 5 × 10(-13) cm(3)/s. Gas-phase advanced oxidation is able to remove compounds that react with OH and to control ozone and total particulate mass. Secondary pollution including formaldehyde and ultrafine particles might be generated, depending on the composition of the primary pollution.
The Development of a Programming Support System for Rapid Prototyping. Tasks 2 and 3.
1985-01-01
of the problems that played a role in the larger system. The principal work in Task 2 was the design of a new method for code-generation...develop- Ing a prototype of the interpreter. Due to the limitation of funds, only a design , not a prototype of the bi-directional l 2 scanner was...Introduction LiTmitUn uupii The Problem of designing a code generator for an interpreter-based languae Jas provided a chance to reoexamine fth
Mechanism of Phosphorus Removal from Hanford Tank Sludge by Caustic Leaching
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lumetta, Gregg J.
Two experiments were conducted to explore the mechanism by which phosphorus is removed from Hanford tank sludge by caustic leaching. In the first experiment, a series of phosphate salts were treated with 3 M NaOH under conditions prototypic of the actual leaching process to be performed in the Waste Treatment and Immobilization Plant (WTP). The phosphates used were aluminum phosphate, bismuth phosphate, chromium(III) phosphate, and β-tri-calcium phosphate; all of these phases have previously been determined to exist in Hanford tank sludge. The leachate solution was sampled at selected time intervals and analyzed for the specific metal ion involved (Al, Bi,more » Ca, or Cr) and for P (total and as phosphate). The solids remaining after completion of the caustic leaching step were analyzed to determine the reaction product. In the second experiment, the dependence of P removal from bismuth phosphate was examined as a function of the hydroxide ion concentration. It was anticipated that a plot of log[phosphate] versus log[hydroxide] would provide insight into the phosphorus-removal mechanism. This report describes the test activities outlined in Section 6.3.2.1, Preliminary Investigation of Phosphate Dissolution, in Test Plan TP-RPP-WTP-467, Rev.1. The objectives, success criteria, and test conditions of Section 6.3.2.1 are summarized here.« less
Influence of the astrophysical requirements on dilution refrigerator design
NASA Astrophysics Data System (ADS)
Sirbi, Adriana; Pouilloux, Benjamin; Benoit, Alain; Lamarre, Jean-Michel
1999-12-01
A 300 K to 0.1 K space prototype is developed in cooperation with CRTBT, IAS Air Liquide and RAL, under CNES and ESA contracts, to demonstrate the feasibility of such a cooling system. The heart of the system is a 4 K to 0.1 K open cycle dilution refrigerator circulating 3He and 4He. All the tests are now completed. The design of this system is chosen like the nominal solution for PLANCK/HFI instrument. Since scientific requirements have changed, the design of the prototype has to be adjusted to receive the focal plane of HFI (High Frequency Instrument) instrument of PLANCK. The main goal is to optimise 3He consumption without degrading both mechanical and thermal performances. This paper presents the prototype architecture, the dilution refrigerator and the associated tests. The suitability to PLANCK mission is also assessed.
High resolution analysis of the FTIR spectra of trifluoroamine NF3
NASA Astrophysics Data System (ADS)
Bolotova, I. B.; Ulenikov, O. N.; Bekhtereva, E. S.; Albert, S.; Bauerecker, S.; Hollenstein, H.; Lerch, Ph.; Quack, M.; Peter, T.; Seyfang, G.; Wokaun, A.
2018-06-01
We report high resolution Fourier Transform Infrared (FTIR) spectra of nitrogen trifluoride (trifluoroamine, NF3) measured with the Zürich Bruker prototype spectrometer (ZP 2001) and the SLS THz/FTIR setup (2009 prototype) in the range 20-3000 cm-1 at temperatures between 80 and 120 K using a collisional cooling cell designed with White cell multipath reflection optics and at room temperature (296 K). Except in the far-infrared with instrument limited resolution (Δν˜FWHM = 0.0008 cm-1) many of the spectra are nearly Doppler limited. Rovibrational transitions were assigned to 13 different vibrational bands and were used then in the fitting procedure. We re-investigated the bands 2ν4,ν1,ν2 +ν4,ν1 +ν4 , 2ν3 and ν1 +ν3 , which had been studied before, and we have analyzed the ν2 +ν3 , 2ν1,ν1 +ν2 +ν4,ν1 +ν2 +ν3,ν2 + 2ν3, 3ν3,ν1 + 2ν3 bands for the first time. All our analyses refer to the isotopomer 14 NF3.
NASA Astrophysics Data System (ADS)
Hardy, Luke A.; Hutchens, Thomas C.; Larson, Eric R.; Gonzalez, David A.; Chang, Chun-Hung; Nau, William H.; Fried, Nathaniel M.
2017-05-01
Energy-based, radiofrequency (RF) and ultrasonic (US) devices currently provide rapid sealing of blood vessels during laparoscopic procedures. We are exploring infrared lasers as an alternate energy modality for vessel sealing, capable of generating less collateral thermal damage. Previous studies demonstrated feasibility of sealing vessels in an in vivo porcine model using a 1470-nm laser. However, the initial prototype was designed for testing in open surgery and featured tissue clasping and light delivery mechanisms incompatible with laparoscopic surgery. In this study, a laparoscopic prototype similar to devices currently in surgical use was developed, and performance tests were conducted on porcine renal blood vessels, ex vivo. The 5-mm outer-diameter laparoscopic prototype featured a traditional Maryland jaw configuration that enables tissue manipulation and blunt dissection. Laser energy was delivered through a 550-μm-core-diameter optical fiber with side-delivery from the lower jaw and beam dimensions of 18-mm length×1.2-mm width. The 1470-nm diode laser delivered 68 W with 3-s activation time, consistent with vessel seal times associated with RF and US-based devices. A total of 69 fresh porcine renal vessels with mean diameter of 3.3±1.7 mm were tested, ex vivo. Vessels smaller than 5-mm diameter were consistently sealed (48/51) with burst pressures greater than malignant hypertension blood pressure (180 mmHg), averaging 1038±474 mmHg. Vessels larger than 5 mm were not consistently sealed (6/18), yielding burst pressures of only 174±221 mmHg. Seal width, thermal damage zone, and thermal spread averaged 1.7±0.8, 3.4±0.7, and 1.0±0.4 mm, respectively. Results demonstrated that the 5-mm optical laparoscopic prototype consistently sealed vessels less than 5-mm diameter with low thermal spread. Further in vivo studies are planned to test the performance across a variety of vessels and tissues.
Zaylaa, Amira J; Rashid, Mohamad; Shaib, Mounir; El Majzoub, Imad
2018-01-01
Preterm infants encounter an abrupt delivery before their complete maturity during the third trimester of pregnancy. Polls anticipate an increase in the rates of preterm infants for 2025, especially in middle- and low-income countries. Despite the abundance of intensive care methods for preterm infants, such as, but not limited to, commercial, transport, embrace warmer, radiant warmer, and Kangaroo Mother Care methods, they are either expensive, lack the most essential requirements or specifications, or lack the maternal-preterm bond. This drove us to carry this original research and innovative idea of developing a new 3D printed prototype of a Handy preterm infant incubator. We aim to provide the most indispensable intensive care with the lowest cost, to bestow low-income countries with the Handy incubator's care, preserve the maternal -preterm's bond, and diminish the rate of mortality. Biomedical features, electronics, and biocompatible materials were utilized. The design was simulated, the prototype was 3D printed, and the outcomes were tested and evaluated. Simulation results showed the best fit for the Handy incubator's components. Experimental results showed the 3D-printed prototype and the time elapsed to obtain it. Evaluation results revealed that the overall performance of Kangaroo Mother Care and the embrace warmer was 75 ± 1.4% and 66.7 ± 1.5%, respectively, while the overall performance of our Handy incubator was 91.7 ± 1.6%, thereby our cost-effective Handy incubator surpassed existing intensive care methods. The future step is associating the Handy incubator with more specifications and advancements.
Smulders, M; Berghman, K; Koenraads, M; Kane, J A; Krishna, K; Carter, T K; Schultheis, U
2016-08-12
The concept of comfort is one way for the growing airline market to differentiate and build customer loyalty. This work follows the idea that increasing the contact area between human and seat can have a positive effect on comfort [5, 6, 7]. To improve comfort, reduce weight and optimise space used, a human contour shaped seat shell and cushioning was developed. First the most common activities, the corresponding postures and seat inclination angles were defined. The imprints of these postures on a rescue mat were 3D scanned and an average human contour curve was defined. The outcome was transferred to a prototype seat that was used to test the effect on perceived comfort/discomfort and pressure distribution. The resulting human contour based prototype seat has comfort and discomfort scores comparable to a traditional seat. The prototype seat had a significantly lower average pressure between subjects' buttocks and the seat pan over a traditional seat. This study shows that it is possible to design a seat pan and backrest based on the different contours of study subjects using 3D scan technology. However, translating the 3D scans into a prototype seat also showed that this can only be seen as a first step; additionally biomechanical information and calculations are needed to create ergonomic seats. Furthermore, it is not possible to capture all different human shapes and postures and translate these into one human contour shape that fits all activities and all human sizes.
Prototype residential photovoltaic system: Evaluation results
NASA Astrophysics Data System (ADS)
Nichols, B. E.; Russell, M. C.
1982-09-01
Residential size photovoltaic power systems were discussed. Lessons learned from this experience, and performance summaries for the five prototype systems at the Northeast Residential Experiment Station and the system at the all electric Carlisle PV house are given. Results of evaluating five utility interactive residential size inverters also are reported.
Quantitative evaluation of performance of 3D printed lenses
Gawedzinski, John; Pawlowski, Michal E.; Tkaczyk, Tomasz S.
2017-01-01
We present an analysis of the shape, surface quality, and imaging capabilities of custom 3D printed lenses. 3D printing technology enables lens prototypes to be fabricated without restrictions on surface geometry. Thus, spherical, aspherical and rotationally non-symmetric lenses can be manufactured in an integrated production process. This technique serves as a noteworthy alternative to multistage, labor-intensive, abrasive processes such as grinding, polishing and diamond turning. Here, we evaluate the quality of lenses fabricated by Luxexcel using patented Printoptical© technology that is based on an inkjet printing technique by comparing them to lenses made with traditional glass processing technologies (grinding, polishing etc.). The surface geometry and roughness of the lenses were evaluated using white-light and Fizeau interferometers. We have compared peak-to-valley wavefront deviation, root-mean-squared wavefront error, radii of curvature and the arithmetic average of the roughness profile (Ra) of plastic and glass lenses. Additionally, the imaging performance of selected pairs of lenses was tested using 1951 USAF resolution target. The results indicate performance of 3D printed optics that could be manufactured with surface roughness comparable to that of injection molded lenses (Ra < 20 nm). The RMS wavefront error of 3D printed prototypes was at a minimum 18.8 times larger than equivalent glass prototypes for a lens with a 12.7 mm clear aperture, but when measured within 63% of its clear aperture, 3D printed components’ RMS wavefront error was comparable to glass lenses. PMID:29238114
MIND performance and prototyping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cervera-Villanueva, A.
2008-02-21
The performance of MIND (Magnetised Iron Neutrino Detector) at a neutrino factory has been revisited in a new analysis. In particular, the low neutrino energy region is studied, obtaining an efficiency plateau around 5 GeV for a background level below 10{sup -3}. A first look has been given into the detector optimisation and prototyping.
Conceptualization and application of an approach for designing healthcare software interfaces.
Kumar, Ajit; Maskara, Reena; Maskara, Sanjeev; Chiang, I-Jen
2014-06-01
The aim of this study is to conceptualize a novel approach, which facilitates us to design prototype interfaces for healthcare software. Concepts and techniques from various disciplines were used to conceptualize an interface design approach named MORTARS (Map Original Rhetorical To Adapted Rhetorical Situation). The concepts and techniques included in this approach are (1) rhetorical situation - a concept of philosophy provided by Bitzer (1968); (2) move analysis - an applied linguistic technique provided by Swales (1990) and Bhatia (1993); (3) interface design guidelines - a cognitive and computer science concept provided by Johnson (2010); (4) usability evaluation instrument - an interface evaluation questionnaire provided by Lund (2001); (5) user modeling via stereotyping - a cognitive and computer science concept provided by Rich (1979). A prototype interface for outpatient clinic software was designed to introduce the underlying concepts of MORTARS. The prototype interface was evaluated by thirty-two medical informaticians. The medical informaticians found the designed prototype interface to be useful (73.3%), easy to use (71.9%), easy to learn (93.1%), and satisfactory (53.2%). MORTARS approach was found to be effective in designing the prototype user interface for the outpatient clinic software. This approach might be further used to design interfaces for various software pertaining to healthcare and other domains. Copyright © 2014 Elsevier Inc. All rights reserved.
Giesel, Frederik L; Mehndiratta, Amit; von Tengg-Kobligk, Hendrik; Schaeffer, A; Teh, Kevin; Hoffman, E A; Kauczor, Hans-Ulrich; van Beek, E J R; Wild, Jim M
2009-04-01
Three-dimensional image reconstruction by volume rendering and rapid prototyping has made it possible to visualize anatomic structures in three dimensions for interventional planning and academic research. Volumetric chest computed tomography was performed on a healthy volunteer. Computed tomographic images of the larger bronchial branches were segmented by an extended three-dimensional region-growing algorithm, converted into a stereolithography file, and used for computer-aided design on a laser sintering machine. The injection of gases for respiratory flow modeling and measurements using magnetic resonance imaging were done on a hollow cast. Manufacturing the rapid prototype took about 40 minutes and included the airway tree from trackea to segmental bronchi (fifth generation). The branching of the airways are clearly visible in the (3)He images, and the radial imaging has the potential to elucidate the airway dimensions. The results for flow patterns in the human bronchial tree using the rapid-prototype model with hyperpolarized helium-3 magnetic resonance imaging show the value of this model for flow phantom studies.
Weitz, Jochen; Deppe, Herbert; Stopp, Sebastian; Lueth, Tim; Mueller, Steffen; Hohlweg-Majert, Bettina
2011-12-01
The aim of this study is to evaluate the accuracy of a surgical template-aided implant placement produced by rapid prototyping using a DICOM dataset from cone beam computer tomography (CBCT). On the basis of CBCT scans (Sirona® Galileos), a total of ten models were produced using a rapid-prototyping three-dimensional printer. On the same patients, impressions were performed to compare fitting accuracy of both methods. From the models made by impression, templates were produced and accuracy was compared and analyzed with the rapid-prototyping model. Whereas templates made by conventional procedure had an excellent accuracy, the fitting accuracy of those produced by DICOM datasets was not sufficient. Deviations ranged between 2.0 and 3.5 mm, after modification of models between 1.4 and 3.1 mm. The findings of this study suggest that the accuracy of the low-dose Sirona Galileos® DICOM dataset seems to show a high deviation, which is not useable for accurate surgical transfer for example in implant surgery.
2013-01-01
Background Medical blogs have emerged as new media, extending to a wider range of medical audiences, including health professionals and patients to share health-related information. However, extraction of quality health-related information from medical blogs is challenging primarily because these blogs lack systematic methods to organize their posts. Medical blogs can be categorized according to their author into (1) physician-written blogs, (2) nurse-written blogs, and (3) patient-written blogs. This study focuses on how to organize physician-written blog posts that discuss disease-related issues and how to extract quality information from these posts. Objective The goal of this study was to create and implement a prototype for a Web-based system, called ICDTag, based on a hybrid taxonomy–folksonomy approach that follows a combination of a taxonomy classification schemes and user-generated tags to organize physician-written blog posts and extract information from these posts. Methods First, the design specifications for the Web-based system were identified. This system included two modules: (1) a blogging module that was implemented as one or more blogs, and (2) an aggregator module that aggregated posts from different blogs into an aggregator website. We then developed a prototype for this system in which the blogging module included two blogs, the cardiology blog and the gastroenterology blog. To analyze the usage patterns of the prototype, we conducted an experiment with data provided by cardiologists and gastroenterologists. Next, we conducted two evaluation types: (1) an evaluation of the ICDTag blog, in which the browsing functionalities of the blogging module were evaluated from the end-user’s perspective using an online questionnaire, and (2) an evaluation of information quality, in which the quality of the content on the aggregator website was assessed from the perspective of medical experts using an emailed questionnaire. Results Participants of this experiment included 23 cardiologists and 24 gastroenterologists. Positive evaluations on the main functions and the organization of information on the ICDTag blogs were given by 18 of the participants via an online questionnaire. These results supported our hypothesis that the use of a taxonomy-folksonomy structure has significant potential to improve the organization of information in physician-written blogs. The quality of the content on the aggregator website was assessed by 3 cardiology experts and 3 gastroenterology experts via an email questionnaire. The results of this questionnaire demonstrated that the experts considered the aggregated tags and categories semantically related to the posts’ content. Conclusions This study demonstrated that applying the hybrid taxonomy–folksonomy approach to physician-written blogs that discuss disease-related issues has valuable potential to make these blogs a more organized and systematic medium and supports the extraction of quality information from their posts. Thus, it is worthwhile to develop more mature systems that make use of the hybrid approach to organize posts in physician-written blogs. PMID:23470419
Batch, Yamen; Yusof, Maryati Mohd; Noah, Shahrul Azman
2013-02-27
Medical blogs have emerged as new media, extending to a wider range of medical audiences, including health professionals and patients to share health-related information. However, extraction of quality health-related information from medical blogs is challenging primarily because these blogs lack systematic methods to organize their posts. Medical blogs can be categorized according to their author into (1) physician-written blogs, (2) nurse-written blogs, and (3) patient-written blogs. This study focuses on how to organize physician-written blog posts that discuss disease-related issues and how to extract quality information from these posts. The goal of this study was to create and implement a prototype for a Web-based system, called ICDTag, based on a hybrid taxonomy-folksonomy approach that follows a combination of a taxonomy classification schemes and user-generated tags to organize physician-written blog posts and extract information from these posts. First, the design specifications for the Web-based system were identified. This system included two modules: (1) a blogging module that was implemented as one or more blogs, and (2) an aggregator module that aggregated posts from different blogs into an aggregator website. We then developed a prototype for this system in which the blogging module included two blogs, the cardiology blog and the gastroenterology blog. To analyze the usage patterns of the prototype, we conducted an experiment with data provided by cardiologists and gastroenterologists. Next, we conducted two evaluation types: (1) an evaluation of the ICDTag blog, in which the browsing functionalities of the blogging module were evaluated from the end-user's perspective using an online questionnaire, and (2) an evaluation of information quality, in which the quality of the content on the aggregator website was assessed from the perspective of medical experts using an emailed questionnaire. Participants of this experiment included 23 cardiologists and 24 gastroenterologists. Positive evaluations on the main functions and the organization of information on the ICDTag blogs were given by 18 of the participants via an online questionnaire. These results supported our hypothesis that the use of a taxonomy-folksonomy structure has significant potential to improve the organization of information in physician-written blogs. The quality of the content on the aggregator website was assessed by 3 cardiology experts and 3 gastroenterology experts via an email questionnaire. The results of this questionnaire demonstrated that the experts considered the aggregated tags and categories semantically related to the posts' content. This study demonstrated that applying the hybrid taxonomy-folksonomy approach to physician-written blogs that discuss disease-related issues has valuable potential to make these blogs a more organized and systematic medium and supports the extraction of quality information from their posts. Thus, it is worthwhile to develop more mature systems that make use of the hybrid approach to organize posts in physician-written blogs.
Berry, Jack W; Elliott, Timothy R; Rivera, Patricia
2007-12-01
A sample of 199 persons with spinal cord injury (SCI) were assessed on Big Five personality dimensions using the NEO Five-Factor Inventory (NEO-FFI; Costa & McCrae, 1992) at admission to an inpatient medical rehabilitation program. A cluster analysis of the baseline NEO-FFI yielded 3 cluster prototypes that resemble resilient, undercontrolled, and overcontrolled prototypes identified in many previous studies of children and adult community samples. Compared with normative samples, this sample had significantly fewer resilient prototypes and significantly more overcontrolled and undercontrolled prototypes. Undercontrolled individuals were the modal prototype. The resilient and undercontrolled types were better adjusted than the overcontrolled types, showing lower levels of depression at admission and higher acceptance of disability at discharge. The resilient type at admission predicted the most effective reports of social problem-solving abilities at discharge and the overcontrolled type the least. We discuss the implications of these results for assessment and interventions in rehabilitation settings.
Lee, Haerin; Jung, Moonki; Lee, Ki-Kwang; Lee, Sang Hun
2017-02-06
In this paper, we propose a three-dimensional design and evaluation framework and process based on a probabilistic-based motion synthesis algorithm and biomechanical analysis system for the design of the Smith machine and squat training programs. Moreover, we implemented a prototype system to validate the proposed framework. The framework consists of an integrated human-machine-environment model as well as a squat motion synthesis system and biomechanical analysis system. In the design and evaluation process, we created an integrated model in which interactions between a human body and machine or the ground are modeled as joints with constraints at contact points. Next, we generated Smith squat motion using the motion synthesis program based on a Gaussian process regression algorithm with a set of given values for independent variables. Then, using the biomechanical analysis system, we simulated joint moments and muscle activities from the input of the integrated model and squat motion. We validated the model and algorithm through physical experiments measuring the electromyography (EMG) signals, ground forces, and squat motions as well as through a biomechanical simulation of muscle forces. The proposed approach enables the incorporation of biomechanics in the design process and reduces the need for physical experiments and prototypes in the development of training programs and new Smith machines.
A 3D Human-Machine Integrated Design and Analysis Framework for Squat Exercises with a Smith Machine
Lee, Haerin; Jung, Moonki; Lee, Ki-Kwang; Lee, Sang Hun
2017-01-01
In this paper, we propose a three-dimensional design and evaluation framework and process based on a probabilistic-based motion synthesis algorithm and biomechanical analysis system for the design of the Smith machine and squat training programs. Moreover, we implemented a prototype system to validate the proposed framework. The framework consists of an integrated human–machine–environment model as well as a squat motion synthesis system and biomechanical analysis system. In the design and evaluation process, we created an integrated model in which interactions between a human body and machine or the ground are modeled as joints with constraints at contact points. Next, we generated Smith squat motion using the motion synthesis program based on a Gaussian process regression algorithm with a set of given values for independent variables. Then, using the biomechanical analysis system, we simulated joint moments and muscle activities from the input of the integrated model and squat motion. We validated the model and algorithm through physical experiments measuring the electromyography (EMG) signals, ground forces, and squat motions as well as through a biomechanical simulation of muscle forces. The proposed approach enables the incorporation of biomechanics in the design process and reduces the need for physical experiments and prototypes in the development of training programs and new Smith machines. PMID:28178184
NASA Astrophysics Data System (ADS)
Kafle, N.; Owen, L. W.; Caneses, J. F.; Biewer, T. M.; Caughman, J. B. O.; Donovan, D. C.; Goulding, R. H.; Rapp, J.
2018-05-01
The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory is a linear plasma device that combines a helicon plasma source with additional microwave and radio frequency heating to deliver high plasma heat and particle fluxes to a target. Double Langmuir probes and Thomson scattering are being used to measure local electron temperature and density at various radial and axial locations. A recently constructed Mach-double probe provides the added capability of simultaneously measuring electron temperatures ( T e), electron densities ( n e), and Mach numbers (M). With this diagnostic, it is possible to infer the plasma flow, particle flux, and heat flux at different locations along the plasma column in Proto-MPEX. Preliminary results show Mach numbers of 0.5 (towards the dump plate) and 1.0 (towards the target plate) downstream from the helicon source, and a stagnation point (no flow) near the source for the case where the peak magnetic field was 1.3 T. Measurements of particle flow and ne and Te profiles are discussed. The extensive coverage provided by these diagnostics permits data-constrained B2.5-Eirene modeling of the entire plasma column, and comparison with results of modeling in the high-density helicon plasmas will be presented.
Measurement of the energy and time resolution of a undoped CsI + MPPC array for the Mu2e experiment
Atanova, O.; Cordelli, M.; Corradi, G.; ...
2017-02-13
This paper describes the measurements of energy and time response and resolution of a 3 x 3 array made of undoped CsI crystals coupled to large area Hamamatsu Multi Pixel Photon Counters. The measurements have been performed using the electron beam of the Beam Test Facility in Frascati (Rome, Italy) in the energy range 80-120 MeV. The measured energy resolution, estimated with the FWHM, at 100 MeV is 16.4%. This resolution is dominated by the energy leakage due to the small dimensions of the prototype. The time is reconstructed by fitting the leading edge of the digitized signals and applyingmore » a digital constant fraction discrimination technique. A time resolution of about 110 ps at 100 MeV is achieved.« less
Detection system for neutron β decay correlations in the UCNB and Nab experiments
Broussard, L. J.; Oak Ridge National Lab.; Zeck, B. A.; ...
2016-12-19
Here, we describe a detection system designed to precisely measure multiple correlations in neutron β decay. Furthermore, the system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications of energy thresholds below 10 keV, energy resolution of ~3 keV FWHM, and rise time of ~50 ns with 19 of the 127 detector pixels instrumented. We have demonstrated the coincident detection of β particles and recoil protons from neutron β decay, using ultracold neutrons at the Los Alamos Neutron Science Center, . The fully instrumented detection system willmore » be implemented in the UCNB and Nab experiments, to determine the neutron β decay parameters B, a, and b.« less
DESCANT--The DEuterated SCintillator Array for Neutron Tagging
NASA Astrophysics Data System (ADS)
Bildstein, Vinzenz; Garrett, P. E.; Bandyopadhay, D.; Bangay, J.; Bianco, L.; Demand, G.; Hadinia, B.; Leach, K. G.; Sumithrarachchi, C.; Wong, J.; Ashley, S. F.; Crider, B. P.; McEllistrem, M. T.; Peters, E. E.; Prados-Estévez, F. M.; Yates, S. W.; Vanhoy, J. R.; Ball, G. C.; Garnsworthy, A. B.; Hackman, G.; Pearson, C. J.; Sarazin, F.
2014-09-01
The DESCANT array at TRIUMF is designed to track neutrons from RIB experiments. DESCANT is composed of 70 close-packed deuterated organic liquid scintillators coupled to digital fast read-out ADC modules. This configuration will permit online pulse-shape discrimination between neutron and γ-ray events. The anisotropy of the n - d scattering will allow distinction of higher neutron multiplicities from scattering within the array and determination of the neutron energy spectrum directly from the pulse-height spectrum without using TOF. A prototype detector has been tested with monoenergetic neutrons at the accelerator laboratory of the University of Kentucky and a 24Mg(3He, n)26Si experiment has been performed with eight DESCANT detectors and two HPGe detectors. The results of the tests and the status of DESCANT will be presented.
Javan, Ramin; Zeman, Merissa N
2018-02-01
In the context of medical three-dimensional (3D) printing, in addition to 3D reconstruction from cross-sectional imaging, graphic design plays a role in developing and/or enhancing 3D-printed models. A custom prototype modular 3D model of the liver was graphically designed depicting segmental anatomy of the parenchyma containing color-coded hepatic vasculature and biliary tree. Subsequently, 3D printing was performed using transparent resin for the surface of the liver and polyamide material to develop hollow internal structures that allow for passage of catheters and wires. A number of concepts were incorporated into the model. A representative mass with surrounding feeding arterial supply was embedded to demonstrate tumor embolization. A straight narrow hollow tract connecting the mass to the surface of the liver, displaying the path of a biopsy device's needle, and the concept of needle "throw" length was designed. A connection between the middle hepatic and right portal veins was created to demonstrate transjugular intrahepatic portosystemic shunt (TIPS) placement. A hollow amorphous structure representing an abscess was created to allow the demonstration of drainage catheter placement with the formation of pigtail tip. Percutaneous biliary drain and cholecystostomy tube placement were also represented. The skills of graphic designers may be utilized in creating highly customized 3D-printed models. A model was developed for the demonstration and simulation of multiple hepatobiliary interventions, for training purposes, patient counseling and consenting, and as a prototype for future development of a functioning interventional phantom.
Schulz-Wendtland, Rüdiger; Jud, Sebastian M.; Fasching, Peter A.; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W.; Emons, Julius
2017-01-01
Aim The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Materials and Methods Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. Results The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. Conclusion In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound – the second important imaging modality in complementary breast diagnostics – without increasing examination time or requiring additional staff. PMID:28713173
Lee, M-Y; Chang, C-C; Ku, Y C
2008-01-01
Fixed dental restoration by conventional methods greatly relies on the skill and experience of the dental technician. The quality and accuracy of the final product depends mostly on the technician's subjective judgment. In addition, the traditional manual operation involves many complex procedures, and is a time-consuming and labour-intensive job. Most importantly, no quantitative design and manufacturing information is preserved for future retrieval. In this paper, a new device for scanning the dental profile and reconstructing 3D digital information of a dental model based on a layer-based imaging technique, called abrasive computer tomography (ACT) was designed in-house and proposed for the design of custom dental restoration. The fixed partial dental restoration was then produced by rapid prototyping (RP) and computer numerical control (CNC) machining methods based on the ACT scanned digital information. A force feedback sculptor (FreeForm system, Sensible Technologies, Inc., Cambridge MA, USA), which comprises 3D Touch technology, was applied to modify the morphology and design of the fixed dental restoration. In addition, a comparison of conventional manual operation and digital manufacture using both RP and CNC machining technologies for fixed dental restoration production is presented. Finally, a digital custom fixed restoration manufacturing protocol integrating proposed layer-based dental profile scanning, computer-aided design, 3D force feedback feature modification and advanced fixed restoration manufacturing techniques is illustrated. The proposed method provides solid evidence that computer-aided design and manufacturing technologies may become a new avenue for custom-made fixed restoration design, analysis, and production in the 21st century.
Magnetic field simulation and shimming analysis of 3.0T superconducting MRI system
NASA Astrophysics Data System (ADS)
Yue, Z. K.; Liu, Z. Z.; Tang, G. S.; Zhang, X. C.; Duan, L. J.; Liu, W. C.
2018-04-01
3.0T superconducting magnetic resonance imaging (MRI) system has become the mainstream of modern clinical MRI system because of its high field intensity and high degree of uniformity and stability. It has broad prospects in scientific research and other fields. We analyze the principle of magnet designing in this paper. We also perform the magnetic field simulation and shimming analysis of the first 3.0T/850 superconducting MRI system in the world using the Ansoft Maxwell simulation software. We guide the production and optimization of the prototype based on the results of simulation analysis. Thus the magnetic field strength, magnetic field uniformity and magnetic field stability of the prototype is guided to achieve the expected target.
Update of GRASP/Ada reverse engineering tools for Ada
NASA Technical Reports Server (NTRS)
Cross, James H., II
1993-01-01
The GRASP/Ada project (Graphical Representations of Algorithms, Structures, and Processes for Ada) successfully created and prototyped a new algorithmic level graphical representation for Ada software, the Control Structure Diagram (CSD). The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and, as a result, improve reliability and reduce costs. The emphasis was on the automatic generation of the CSD from Ada PDL or source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional pretty printed Ada source code. In Phase 1 of the GRASP/Ada project, the CSD graphical constructs were created and applied manually to several small Ada programs. A prototype CSD generator (Version 1) was designed and implemented using FLEX and BISON running under VMS on a VAX 11-780. In Phase 2, the prototype was improved and ported to the Sun 4 platform under UNIX. A user interface was designed and partially implemented using the HP widget toolkit and the X Windows System. In Phase 3, the user interface was extensively reworked using the Athena widget toolkit and X Windows. The prototype was applied successfully to numerous Ada programs ranging in size from several hundred to several thousand lines of source code. Following Phase 3,e two update phases were completed. Update'92 focused on the initial analysis of evaluation data collected from software engineering students at Auburn University and the addition of significant enhancements to the user interface. Update'93 (the current update) focused on the statistical analysis of the data collected in the previous update and preparation of Version 3.4 of the prototype for limited distribution to facilitate further evaluation. The current prototype provides the capability for the user to generate CSD's from Ada PDL or source code in a reverse engineering as well as forward engineering mode with a level of flexibility suitable for practical application. An overview of the GRASP/Ada project with an emphasis on the current update is provided.
Fujimura, Takayasu; Uchi, Yukihiko; Fukuda, Makoto; Miyazaki, Miwa; Uezumi, Satoshi; Hiyoshi, Tatsuo
2004-01-01
Accumulated low molecular weight proteins in hemodialysis patients require a high-flux dialyzer. There have been several methods proposed for enhancing internal filtration, including narrowing the inside diameter of the hollow fibers, lengthening the fibers, and increasing the fiber density ratio. We tried to enhance the internal filtration by increasing the pressure drop in the dialysate compartment through increasing the fiber density ratio. If the fiber density ratio is too high, however, an irregular dialysate path may result, thus decreasing dialysis performance. Therefore, we took note of the shape of the inner housing and added a short taper structure, which improved the dialysate path dramatically. Consequently, we developed an internal filtration-enhanced dialyzer (APS-Prototype) to improve dialysis performance. The internal filtration rate in water (measured by Doppler ultrasound) was 13.2 l/session for the APS-Prototype and 5.3 l/session for the APS-15E. The amount of alpha1-microglobulin (alpha1-MG) in bovine plasma was 0.34 g for the APS-Prototype and 0.11 g for the APS-15E. In addition, the amount of alpha1-MG in vivo was 29.0% +/- 5.8% for the APS-Prototype, significantly higher than that for the APS-15E (13.6% +/- 1.9%). The desirable loss of albumin is 2-4 g in hemodiafiltration, and it was 3.92 +/- 1.03 g for the APS-Prototype. The prototype showed excellent solute removal performance with no clinical or engineering problems.
The development of a program analysis environment for Ada: Reverse engineering tools for Ada
NASA Technical Reports Server (NTRS)
Cross, James H., II
1991-01-01
The Graphical Representations of Algorithms, Structures, and Processes for Ada (GRASP/Ada) has successfully created and prototyped a new algorithm level graphical representation for Ada software, the Control Structure Diagram (CSD). The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and thus improve reliability and reduce costs. The emphasis was on the automatic generation of the CSD from Ada source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional prettyprinted Ada source code. In Phase 1 of the GRASP/Ada project, the CSD graphical constructs were created and applied manually to several small Ada programs. A prototype (Version 1) was designed and implemented using FLEX and BISON running under the Virtual Memory System (VMS) on a VAX 11-780. In Phase 2, the prototype was improved and ported to the Sun 4 platform under UNIX. A user interface was designed and partially implemented. The prototype was applied successfully to numerous Ada programs ranging in size from several hundred to several thousand lines of source code. In Phase 3 of the project, the prototype was prepared for limited distribution (GRASP/Ada Version 3.0) to facilitate evaluation. The user interface was extensively reworked. The current prototype provides the capability for the user to generate CSD from Ada source code in a reverse engineering mode with a level of flexibility suitable for practical application.
Modeling and Analysis of High Torque Density Transverse Flux Machines for Direct-Drive Applications
NASA Astrophysics Data System (ADS)
Hasan, Iftekhar
Commercially available permanent magnet synchronous machines (PMSM) typically use rare-earth-based permanent magnets (PM). However, volatility and uncertainty associated with the supply and cost of rare-earth magnets have caused a push for increased research into the development of non-rare-earth based PM machines and reluctance machines. Compared to other PMSM topologies, the Transverse Flux Machine (TFM) is a promising candidate to get higher torque densities at low speed for direct-drive applications, using non-rare-earth based PMs. The TFMs can be designed with a very small pole pitch which allows them to attain higher force density than conventional radial flux machines (RFM) and axial flux machines (AFM). This dissertation presents the modeling, electromagnetic design, vibration analysis, and prototype development of a novel non-rare-earth based PM-TFM for a direct-drive wind turbine application. The proposed TFM addresses the issues of low power factor, cogging torque, and torque ripple during the electromagnetic design phase. An improved Magnetic Equivalent Circuit (MEC) based analytical model was developed as an alternative to the time-consuming 3D Finite Element Analysis (FEA) for faster electromagnetic analysis of the TFM. The accuracy and reliability of the MEC model were verified, both with 3D-FEA and experimental results. The improved MEC model was integrated with a Particle Swarm Optimization (PSO) algorithm to further enhance the capability of the analytical tool for performing rigorous optimization of performance-sensitive machine design parameters to extract the highest torque density for rated speed. A novel concept of integrating the rotary transformer within the proposed TFM design was explored to completely eliminate the use of magnets from the TFM. While keeping the same machine envelope, and without changing the stator or rotor cores, the primary and secondary of a rotary transformer were embedded into the double-sided TFM. The proposed structure allowed for improved flux-weakening capabilities of the TFM for wide speed operations. The electromagnetic design feature of stator pole shaping was used to address the issue of cogging torque and torque ripple in 3-phase TFM. The slant-pole tooth-face in the stator showed significant improvements in cogging torque and torque ripple performance during the 3-phase FEA analysis of the TFM. A detailed structural analysis for the proposed TFM was done prior to the prototype development to validate the structural integrity of the TFM design at rated and maximum speed operation. Vibration performance of the TFM was investigated to determine the structural performance of the TFM under resonance. The prototype for the proposed TFM was developed at the Alternative Energy Laboratory of the University of Akron. The working prototype is a testament to the feasibility of developing and implementing the novel TFM design proposed in this research. Experiments were performed to validate the 3D-FEA electromagnetic and vibration performance result.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamaoka, Kazutaka; Yoshida, Atsumasa; Kotani, Taro
The CALET mission is a Japanese-led effort involving candidate experiments on the International Space Station, planned for launch in 2013. The CALET main detector is a pair conversion telescope which is dedicated to observing high energy electrons and gamma-rays in the GeV-TeV range. CALET can observe gamma-ray bursts over an unprecedented 9 decade energy range from {approx}keV to {approx}TeV with a combination of a gamma-ray burst monitor (GBM) with low energy coverage. GBM is now designed as multiple scintillators made of BGO and LaBr{sub 3}(Ce) scintillators. The prototype LaBr{sub 3}(Ce) crystal with 3 inch diameter and 0.5 inch thickness displaysmore » a very good performance: 2.9{+-}0.1% FWHM energy resolution at 662 keV and 4 keV lower energy threshold. Furthermore, degradations in performance by the anticipated proton irradiation in the orbit are not significant. Results on proton-induced background are also presented.« less
I(CES)-cubes: a modular self-reconfigurable bipartite robotic system
NASA Astrophysics Data System (ADS)
Unsal, Cem; Kiliccote, Han; Khosla, Pradeep K.
1999-08-01
In this manuscript, we introduce I(CES)-Cubes, a class of 3D modular robotic system that is capable of reconfiguring itself in order to adapt to its environment. This is a bipartite system, i.e. a collection of (i) active elements capable of actuation, and (ii) passive elements acting as connectors between actuated elements. Active elements, called links, are 3-DOF manipulators that are capable of attaching/detaching themselves to/from the passive elements. The cubes can then be positioned and oriented using links, which are independent mechatronic elements. Self- reconfiguration property enables the system to performed locomotion tasks over difficult terrain. For example, the system would be capable of moving over obstacles and climbing stairs. These task are performed by positing and orienting cubes and links to form a 3D network with required shape and position. This paper describes the design of the passive and active elements, the attachment mechanics, and several reconfiguration scenarios. Specifics of the hardware implementation and result of experiments with current prototypes are also given.
Endocavity Ultrasound Probe Manipulators
Stoianovici, Dan; Kim, Chunwoo; Schäfer, Felix; Huang, Chien-Ming; Zuo, Yihe; Petrisor, Doru; Han, Misop
2014-01-01
We developed two similar structure manipulators for medical endocavity ultrasound probes with 3 and 4 degrees of freedom (DoF). These robots allow scanning with ultrasound for 3-D imaging and enable robot-assisted image-guided procedures. Both robots use remote center of motion kinematics, characteristic of medical robots. The 4-DoF robot provides unrestricted manipulation of the endocavity probe. With the 3-DoF robot the insertion motion of the probe must be adjusted manually, but the device is simpler and may also be used to manipulate external-body probes. The robots enabled a novel surgical approach of using intraoperative image-based navigation during robot-assisted laparoscopic prostatectomy (RALP), performed with concurrent use of two robotic systems (Tandem, T-RALP). Thus far, a clinical trial for evaluation of safety and feasibility has been performed successfully on 46 patients. This paper describes the architecture and design of the robots, the two prototypes, control features related to safety, preclinical experiments, and the T-RALP procedure. PMID:24795525
Tough Al-alginate/poly(N-isopropylacrylamide) hydrogel with tunable LCST for soft robotics.
Zheng, Wen Jiang; An, Ning; Yang, Jian Hai; Zhou, Jinxiong; Chen, Yong Mei
2015-01-28
Tough Al-alginate/poly(N-isopropylacrylamide) (PNIPAM) hydrogel has been synthesized by introducing an interpenetrating network with hybrid physically cross-linked alginate and chemically cross-linked PNIPAM. Varying the concentration of AlCl3 regulates the mechanical properties of the tough hydrogel and tunes its lower critical solution temperature (LCST) as well. The tough Al-alginate/PNIPAM exhibits 6.3 ± 0.3 MPa of compressive stress and 9.95 of uniaxial stretch. Tunability of LCST is also achieved in a wide range within 22.5-32 °C. A bending beam actuator and a four-arm gripper made of bilayer (Na-alginate/PNIPAM)/(Al-alginate/PNIPAM) hydrogel as prototype of all-hydrogel soft robotics are demonstrated. A finite element (FE) simulation model is developed to simulate the deformation of the soft robotics. The FE simulation not only reproduces the deformation process of performed experiments but also predicts more complicated devices that can be explored in the future. This work broadens the application of temperature-responsive PNIPAM-based hydrogels.
A large surface photomultiplier based on SiPMs
NASA Astrophysics Data System (ADS)
Barbarino, Giancarlo; de Asmundis, Riccardo; De Rosa, Gianfranca; Vivolo, Daniele; Mollo, Carlos Maximiliano
2013-10-01
Light detection through photosensitive devices represents one of the key issues for a large variety of experiments. In the recent years, Silicon PhotoMultipliers (SiPMs) based on limited Geiger-mode avalanche have been extensively studied in view of their future applications. However, their use is strongly limited by their small sensitive surfaces and by the fact that any increment in the surface turns out into an increase of the dark count rate. In the present work we describe the dark count rate reduction obtained by using a FPGA-based logical circuit for fast pre-processing of pulses from a 3×3 matrix of SiPMs. The prototype we developed supports two SiPMs: we show that a rate reduction from 6.6 Mcps (Mega counts per second) down to 0.436 Mcps at the lowest threshold (0.5 photon-equivalent) and from 1.2 kcps down to 0.02 cps for the highest threshold (3.5 photon-equivalent) is obtainable.
Investigating 3-body Decays of Cluster States with the PAT-TPC
NASA Astrophysics Data System (ADS)
Carpenter, Lisa; Ayyad Limonge, Y.; Bazin, D.; Beceiro-Novo, S.; Bradt, J.; Cortesi, M.; Mittig, W.; Ahn, T.; Kolata, J. J.; Meisel, Z.; Bechetti, F. D.; Fritsch, A.; Howard, A.
2016-03-01
Recent model calculations with most advanced methods for cluster states have shown the need of experimental data to probe the structure of light exotic nuclei, including those with α-clustering, such as 14C. The Prototype Active Target Time Projection Chamber (PAT-TPC) allows us to investigate these types of structures, giving access to the full excitation function with a single beam energy. This type of experiment measures resonances in 14C that can be compared to the models. With an improved Micromegas pad plane with a circular backgammon design we are able to investigate 3-body decays in addition to 2-body scattering. The measurements were carried out by resonant alpha-scattering on 10Be beam delivered by the TwinSol facility at the University of Notre Dame. We also observed the 3-body decay of the Hoyle State in 12C from a 12N or 12B beam with the same device. Preliminary results will be presented. This work is supported by the National Science Foundation.
Leitner, T.; Mazza, T.; Schröder, H.; Kunnus, K.; Schreck, S.; Radcliffe, P.; Düsterer, S.; Meyer, M.; Föhlisch, A.
2017-01-01
We prove the hitherto hypothesized sequential dissociation of Fe(CO)5 in the gas phase upon photoexcitation at 266 nm via a singlet pathway with time-resolved valence and core-level photoelectron spectroscopy with an x-ray free-electron laser. Valence photoelectron spectra are used to identify free CO molecules and to determine the time constants of stepwise dissociation to Fe(CO)4 within the temporal resolution of the experiment and further to Fe(CO)3 within 3 ps. Fe 3p core-level photoelectron spectra directly reflect the singlet spin state of the Fe center in Fe(CO)5, Fe(CO)4, and Fe(CO)3 showing that the dissociation exclusively occurs along a singlet pathway without triplet-state contribution. Our results are important for assessing intra- and intermolecular relaxation processes in the photodissociation dynamics of the prototypical Fe(CO)5 complex in the gas phase and in solution, and they establish time-resolved core-level photoelectron spectroscopy as a powerful tool for determining the multiplicity of transition metals in photochemical reactions of coordination complexes. PMID:28595420
Viewing zone duplication of multi-projection 3D display system using uniaxial crystal.
Lee, Chang-Kun; Park, Soon-Gi; Moon, Seokil; Lee, Byoungho
2016-04-18
We propose a novel multiplexing technique for increasing the viewing zone of a multi-view based multi-projection 3D display system by employing double refraction in uniaxial crystal. When linearly polarized images from projector pass through the uniaxial crystal, two possible optical paths exist according to the polarization states of image. Therefore, the optical paths of the image could be changed, and the viewing zone is shifted in a lateral direction. The polarization modulation of the image from a single projection unit enables us to generate two viewing zones at different positions. For realizing full-color images at each viewing zone, a polarization-based temporal multiplexing technique is adopted with a conventional polarization switching device of liquid crystal (LC) display. Through experiments, a prototype of a ten-view multi-projection 3D display system presenting full-colored view images is implemented by combining five laser scanning projectors, an optically clear calcite (CaCO3) crystal, and an LC polarization rotator. For each time sequence of temporal multiplexing, the luminance distribution of the proposed system is measured and analyzed.
NASA Astrophysics Data System (ADS)
Horswell, I.; Gimenez, E. N.; Marchal, J.; Tartoni, N.
2011-01-01
Hybrid silicon photon-counting detectors are becoming standard equipment for many synchrotron applications. The latest in the Medipix family of read-out chips designed as part of the Medipix Collaboration at CERN is the Medipix3, which while maintaining the same pixel size as its predecessor, offers increased functionality and operating modes. The active area of the Medipix3 chip is approx 14mm × 14mm (containing 256 × 256 pixels) which is not large enough for many detector applications, this results in the need to tile many sensors and chips. As a first step on the road to develop such a detector, it was decided to build a prototype single chip readout system to gain the necessary experience in operating a Medipix3 chip. To provide a flexible learning and development tool it was decided to build an interface based on the recently released FlexRIOTM system from National Instruments and to use the LabVIEWTM graphical programming environment. This system and the achieved performance are described in this paper.