Quasi-Experimental Designs for Causal Inference
ERIC Educational Resources Information Center
Kim, Yongnam; Steiner, Peter
2016-01-01
When randomized experiments are infeasible, quasi-experimental designs can be exploited to evaluate causal treatment effects. The strongest quasi-experimental designs for causal inference are regression discontinuity designs, instrumental variable designs, matching and propensity score designs, and comparative interrupted time series designs. This…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-01
... on the Experimental Study of Comparative Direct-to-Consumer (DTC) Advertising. This study is designed... indirect comparisons, using comparative visuals, and using vaguer language. This study is designed to apply... Effectiveness) studies designed to explore comparative effectiveness. When this large project is completed, FDA...
Advanced Technology for Ultra-Low Power System-on-Chip (SoC)
2017-06-01
design at IDS=1mA/μm compared with that in experimental 14nm-node FinFET. The redistributed electric field along the channel length direction can... design can result in more uniform electron density and electron velocity distributions compared to a homojunction device. This uniform electron... design at IDS=1mA/μm compared with that in experimental 14nm-node FinFET. 14 Approved for public release, distribution is unlimited. 0 5 10 15 20
A Response to Paul Stapleton's "Critiquing Research Methodology"
ERIC Educational Resources Information Center
Ross, Steven J.
2006-01-01
Paul Stapleton's (2006) critique of quantitative research brings to the surface some common interpretive problems arising when experimental and quasi-experimental research designs are compared. While Stapleton may be correct in pointing out the superiority of experimental research designs because they best eliminate the influence of extraneous…
Chiang, Kuo-Szu; Bock, Clive H; Lee, I-Hsuan; El Jarroudi, Moussa; Delfosse, Philippe
2016-12-01
The effect of rater bias and assessment method on hypothesis testing was studied for representative experimental designs for plant disease assessment using balanced and unbalanced data sets. Data sets with the same number of replicate estimates for each of two treatments are termed "balanced" and those with unequal numbers of replicate estimates are termed "unbalanced". The three assessment methods considered were nearest percent estimates (NPEs), an amended 10% incremental scale, and the Horsfall-Barratt (H-B) scale. Estimates of severity of Septoria leaf blotch on leaves of winter wheat were used to develop distributions for a simulation model. The experimental designs are presented here in the context of simulation experiments which consider the optimal design for the number of specimens (individual units sampled) and the number of replicate estimates per specimen for a fixed total number of observations (total sample size for the treatments being compared). The criterion used to gauge each method was the power of the hypothesis test. As expected, at a given fixed number of observations, the balanced experimental designs invariably resulted in a higher power compared with the unbalanced designs at different disease severity means, mean differences, and variances. Based on these results, with unbiased estimates using NPE, the recommended number of replicate estimates taken per specimen is 2 (from a sample of specimens of at least 30), because this conserves resources. Furthermore, for biased estimates, an apparent difference in the power of the hypothesis test was observed between assessment methods and between experimental designs. Results indicated that, regardless of experimental design or rater bias, an amended 10% incremental scale has slightly less power compared with NPEs, and that the H-B scale is more likely than the others to cause a type II error. These results suggest that choice of assessment method, optimizing sample number and number of replicate estimates, and using a balanced experimental design are important criteria to consider to maximize the power of hypothesis tests for comparing treatments using disease severity estimates.
NASA Technical Reports Server (NTRS)
Cliff, Susan E.; Baker, Timothy J.; Hicks, Raymond M.; Reuther, James J.
1999-01-01
Two supersonic transport configurations designed by use of non-linear aerodynamic optimization methods are compared with a linearly designed baseline configuration. One optimized configuration, designated Ames 7-04, was designed at NASA Ames Research Center using an Euler flow solver, and the other, designated Boeing W27, was designed at Boeing using a full-potential method. The two optimized configurations and the baseline were tested in the NASA Langley Unitary Plan Supersonic Wind Tunnel to evaluate the non-linear design optimization methodologies. In addition, the experimental results are compared with computational predictions for each of the three configurations from the Enter flow solver, AIRPLANE. The computational and experimental results both indicate moderate to substantial performance gains for the optimized configurations over the baseline configuration. The computed performance changes with and without diverters and nacelles were in excellent agreement with experiment for all three models. Comparisons of the computational and experimental cruise drag increments for the optimized configurations relative to the baseline show excellent agreement for the model designed by the Euler method, but poorer comparisons were found for the configuration designed by the full-potential code.
Optimizing Experimental Design for Comparing Models of Brain Function
Daunizeau, Jean; Preuschoff, Kerstin; Friston, Karl; Stephan, Klaas
2011-01-01
This article presents the first attempt to formalize the optimization of experimental design with the aim of comparing models of brain function based on neuroimaging data. We demonstrate our approach in the context of Dynamic Causal Modelling (DCM), which relates experimental manipulations to observed network dynamics (via hidden neuronal states) and provides an inference framework for selecting among candidate models. Here, we show how to optimize the sensitivity of model selection by choosing among experimental designs according to their respective model selection accuracy. Using Bayesian decision theory, we (i) derive the Laplace-Chernoff risk for model selection, (ii) disclose its relationship with classical design optimality criteria and (iii) assess its sensitivity to basic modelling assumptions. We then evaluate the approach when identifying brain networks using DCM. Monte-Carlo simulations and empirical analyses of fMRI data from a simple bimanual motor task in humans serve to demonstrate the relationship between network identification and the optimal experimental design. For example, we show that deciding whether there is a feedback connection requires shorter epoch durations, relative to asking whether there is experimentally induced change in a connection that is known to be present. Finally, we discuss limitations and potential extensions of this work. PMID:22125485
Trade-offs in experimental designs for estimating post-release mortality in containment studies
Rogers, Mark W.; Barbour, Andrew B; Wilson, Kyle L
2014-01-01
Estimates of post-release mortality (PRM) facilitate accounting for unintended deaths from fishery activities and contribute to development of fishery regulations and harvest quotas. The most popular method for estimating PRM employs containers for comparing control and treatment fish, yet guidance for experimental design of PRM studies with containers is lacking. We used simulations to evaluate trade-offs in the number of containers (replicates) employed versus the number of fish-per container when estimating tagging mortality. We also investigated effects of control fish survival and how among container variation in survival affects the ability to detect additive mortality. Simulations revealed that high experimental effort was required when: (1) additive treatment mortality was small, (2) control fish mortality was non-negligible, and (3) among container variability in control fish mortality exceeded 10% of the mean. We provided programming code to allow investigators to compare alternative designs for their individual scenarios and expose trade-offs among experimental design options. Results from our simulations and simulation code will help investigators develop efficient PRM experimental designs for precise mortality assessment.
Optimal Experimental Design for Model Discrimination
Myung, Jay I.; Pitt, Mark A.
2009-01-01
Models of a psychological process can be difficult to discriminate experimentally because it is not easy to determine the values of the critical design variables (e.g., presentation schedule, stimulus structure) that will be most informative in differentiating them. Recent developments in sampling-based search methods in statistics make it possible to determine these values, and thereby identify an optimal experimental design. After describing the method, it is demonstrated in two content areas in cognitive psychology in which models are highly competitive: retention (i.e., forgetting) and categorization. The optimal design is compared with the quality of designs used in the literature. The findings demonstrate that design optimization has the potential to increase the informativeness of the experimental method. PMID:19618983
2013-04-01
demonstration test . 5.1 CONCEPTUAL EXPERIMENTAL DESIGN In concept, the active biobarrier approach involved the use of alternating extraction and injection...16 4.3 GROUNDWATER CHEMISTRY ....................................................................... 18 5.0 TEST DESIGN...20 5.1 CONCEPTUAL EXPERIMENTAL DESIGN
Schlosser, Ralf W; Belfiore, Phillip J; Sigafoos, Jeff; Briesch, Amy M; Wendt, Oliver
2018-05-28
Evidence-based practice as a process requires the appraisal of research as a critical step. In the field of developmental disabilities, single-case experimental designs (SCEDs) figure prominently as a means for evaluating the effectiveness of non-reversible instructional interventions. Comparative SCEDs contrast two or more instructional interventions to document their relative effectiveness and efficiency. As such, these designs have great potential to inform evidence-based decision-making. To harness this potential, however, interventionists and authors of systematic reviews need tools to appraise the evidence generated by these designs. Our literature review revealed that existing tools do not adequately address the specific methodological considerations of comparative SCEDs that aim to compare instructional interventions of non-reversible target behaviors. The purpose of this paper is to introduce the Comparative Single-Case Experimental Design Rating System (CSCEDARS, "cedars") as a tool for appraising the internal validity of comparative SCEDs of two or more non-reversible instructional interventions. Pertinent literature will be reviewed to establish the need for this tool and to underpin the rationales for individual rating items. Initial reliability information will be provided as well. Finally, directions for instrument validation will be proposed. Copyright © 2018 Elsevier Ltd. All rights reserved.
Kinter, Elizabeth T; Prior, Thomas J; Carswell, Christopher I; Bridges, John F P
2012-01-01
While the application of conjoint analysis and discrete-choice experiments in health are now widely accepted, a healthy debate exists around competing approaches to experimental design. There remains, however, a paucity of experimental evidence comparing competing design approaches and their impact on the application of these methods in patient-centered outcomes research. Our objectives were to directly compare the choice-model parameters and predictions of an orthogonal and a D-efficient experimental design using a randomized trial (i.e., an experiment on experiments) within an application of conjoint analysis studying patient-centered outcomes among outpatients diagnosed with schizophrenia in Germany. Outpatients diagnosed with schizophrenia were surveyed and randomized to receive choice tasks developed using either an orthogonal or a D-efficient experimental design. The choice tasks elicited judgments from the respondents as to which of two patient profiles (varying across seven outcomes and process attributes) was preferable from their own perspective. The results from the two survey designs were analyzed using the multinomial logit model, and the resulting parameter estimates and their robust standard errors were compared across the two arms of the study (i.e., the orthogonal and D-efficient designs). The predictive performances of the two resulting models were also compared by computing their percentage of survey responses classified correctly, and the potential for variation in scale between the two designs of the experiments was tested statistically and explored graphically. The results of the two models were statistically identical. No difference was found using an overall chi-squared test of equality for the seven parameters (p = 0.69) or via uncorrected pairwise comparisons of the parameter estimates (p-values ranged from 0.30 to 0.98). The D-efficient design resulted in directionally smaller standard errors for six of the seven parameters, of which only two were statistically significant, and no differences were found in the observed D-efficiencies of their standard errors (p = 0.62). The D-efficient design resulted in poorer predictive performance, but this was not significant (p = 0.73); there was some evidence that the parameters of the D-efficient design were biased marginally towards the null. While no statistical difference in scale was detected between the two designs (p = 0.74), the D-efficient design had a higher relative scale (1.06). This could be observed when the parameters were explored graphically, as the D-efficient parameters were lower. Our results indicate that orthogonal and D-efficient experimental designs have produced results that are statistically equivalent. This said, we have identified several qualitative findings that speak to the potential differences in these results that may have been statistically identified in a larger sample. While more comparative studies focused on the statistical efficiency of competing design strategies are needed, a more pressing research problem is to document the impact the experimental design has on respondent efficiency.
Reliability-based structural optimization: A proposed analytical-experimental study
NASA Technical Reports Server (NTRS)
Stroud, W. Jefferson; Nikolaidis, Efstratios
1993-01-01
An analytical and experimental study for assessing the potential of reliability-based structural optimization is proposed and described. In the study, competing designs obtained by deterministic and reliability-based optimization are compared. The experimental portion of the study is practical because the structure selected is a modular, actively and passively controlled truss that consists of many identical members, and because the competing designs are compared in terms of their dynamic performance and are not destroyed if failure occurs. The analytical portion of this study is illustrated on a 10-bar truss example. In the illustrative example, it is shown that reliability-based optimization can yield a design that is superior to an alternative design obtained by deterministic optimization. These analytical results provide motivation for the proposed study, which is underway.
Selecting the best design for nonstandard toxicology experiments.
Webb, Jennifer M; Smucker, Byran J; Bailer, A John
2014-10-01
Although many experiments in environmental toxicology use standard statistical experimental designs, there are situations that arise where no such standard design is natural or applicable because of logistical constraints. For example, the layout of a laboratory may suggest that each shelf serve as a block, with the number of experimental units per shelf either greater than or less than the number of treatments in a way that precludes the use of a typical block design. In such cases, an effective and powerful alternative is to employ optimal experimental design principles, a strategy that produces designs with precise statistical estimates. Here, a D-optimal design was generated for an experiment in environmental toxicology that has 2 factors, 16 treatments, and constraints similar to those described above. After initial consideration of a randomized complete block design and an intuitive cyclic design, it was decided to compare a D-optimal design and a slightly more complicated version of the cyclic design. Simulations were conducted generating random responses under a variety of scenarios that reflect conditions motivated by a similar toxicology study, and the designs were evaluated via D-efficiency as well as by a power analysis. The cyclic design performed well compared to the D-optimal design. © 2014 SETAC.
USDA-ARS?s Scientific Manuscript database
Selection of experimental design can markedly influence efficiency of field research. This study used Monte Carlo simulations to compare the ability of different field experimental designs to distinguish defined treatment differences, and the paper concludes with a section on practical use of the in...
Experimental design matters for statistical analysis: how to handle blocking.
Jensen, Signe M; Schaarschmidt, Frank; Onofri, Andrea; Ritz, Christian
2018-03-01
Nowadays, evaluation of the effects of pesticides often relies on experimental designs that involve multiple concentrations of the pesticide of interest or multiple pesticides at specific comparable concentrations and, possibly, secondary factors of interest. Unfortunately, the experimental design is often more or less neglected when analysing data. Two data examples were analysed using different modelling strategies. First, in a randomized complete block design, mean heights of maize treated with a herbicide and one of several adjuvants were compared. Second, translocation of an insecticide applied to maize as a seed treatment was evaluated using incomplete data from an unbalanced design with several layers of hierarchical sampling. Extensive simulations were carried out to further substantiate the effects of different modelling strategies. It was shown that results from suboptimal approaches (two-sample t-tests and ordinary ANOVA assuming independent observations) may be both quantitatively and qualitatively different from the results obtained using an appropriate linear mixed model. The simulations demonstrated that the different approaches may lead to differences in coverage percentages of confidence intervals and type 1 error rates, confirming that misleading conclusions can easily happen when an inappropriate statistical approach is chosen. To ensure that experimental data are summarized appropriately, avoiding misleading conclusions, the experimental design should duly be reflected in the choice of statistical approaches and models. We recommend that author guidelines should explicitly point out that authors need to indicate how the statistical analysis reflects the experimental design. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
NASA Technical Reports Server (NTRS)
Maghami, Peiman G.; Gupta, Sandeep; Elliott, Kenny B.; Joshi, Suresh M.; Walz, Joseph E.
1994-01-01
This paper describes the first experimental validation of an optimization-based integrated controls-structures design methodology for a class of flexible space structures. The Controls-Structures-Interaction (CSI) Evolutionary Model, a laboratory test bed at Langley, is redesigned based on the integrated design methodology with two different dissipative control strategies. The redesigned structure is fabricated, assembled in the laboratory, and experimentally compared with the original test structure. Design guides are proposed and used in the integrated design process to ensure that the resulting structure can be fabricated. Experimental results indicate that the integrated design requires greater than 60 percent less average control power (by thruster actuators) than the conventional control-optimized design while maintaining the required line-of-sight performance, thereby confirming the analytical findings about the superiority of the integrated design methodology. Amenability of the integrated design structure to other control strategies is considered and evaluated analytically and experimentally. This work also demonstrates the capabilities of the Langley-developed design tool CSI DESIGN which provides a unified environment for structural and control design.
Stated Choice design comparison in a developing country: recall and attribute nonattendance
2014-01-01
Background Experimental designs constitute a vital component of all Stated Choice (aka discrete choice experiment) studies. However, there exists limited empirical evaluation of the statistical benefits of Stated Choice (SC) experimental designs that employ non-zero prior estimates in constructing non-orthogonal constrained designs. This paper statistically compares the performance of contrasting SC experimental designs. In so doing, the effect of respondent literacy on patterns of Attribute non-Attendance (ANA) across fractional factorial orthogonal and efficient designs is also evaluated. The study uses a ‘real’ SC design to model consumer choice of primary health care providers in rural north India. A total of 623 respondents were sampled across four villages in Uttar Pradesh, India. Methods Comparison of orthogonal and efficient SC experimental designs is based on several measures. Appropriate comparison of each design’s respective efficiency measure is made using D-error results. Standardised Akaike Information Criteria are compared between designs and across recall periods. Comparisons control for stated and inferred ANA. Coefficient and standard error estimates are also compared. Results The added complexity of the efficient SC design, theorised elsewhere, is reflected in higher estimated amounts of ANA among illiterate respondents. However, controlling for ANA using stated and inferred methods consistently shows that the efficient design performs statistically better. Modelling SC data from the orthogonal and efficient design shows that model-fit of the efficient design outperform the orthogonal design when using a 14-day recall period. The performance of the orthogonal design, with respect to standardised AIC model-fit, is better when longer recall periods of 30-days, 6-months and 12-months are used. Conclusions The effect of the efficient design’s cognitive demand is apparent among literate and illiterate respondents, although, more pronounced among illiterate respondents. This study empirically confirms that relaxing the orthogonality constraint of SC experimental designs increases the information collected in choice tasks, subject to the accuracy of the non-zero priors in the design and the correct specification of a ‘real’ SC recall period. PMID:25386388
Study design elements for rigorous quasi-experimental comparative effectiveness research.
Maciejewski, Matthew L; Curtis, Lesley H; Dowd, Bryan
2013-03-01
Quasi-experiments are likely to be the workhorse study design used to generate evidence about the comparative effectiveness of alternative treatments, because of their feasibility, timeliness, affordability and external validity compared with randomized trials. In this review, we outline potential sources of discordance in results between quasi-experiments and experiments, review study design choices that can improve the internal validity of quasi-experiments, and outline innovative data linkage strategies that may be particularly useful in quasi-experimental comparative effectiveness research. There is an urgent need to resolve the debate about the evidentiary value of quasi-experiments since equal consideration of rigorous quasi-experiments will broaden the base of evidence that can be brought to bear in clinical decision-making and governmental policy-making.
Comparison of GLIMPS and HFAST Stirling engine code predictions with experimental data
NASA Technical Reports Server (NTRS)
Geng, Steven M.; Tew, Roy C.
1992-01-01
Predictions from GLIMPS and HFAST design codes are compared with experimental data for the RE-1000 and SPRE free piston Stirling engines. Engine performance and available power loss predictions are compared. Differences exist between GLIMPS and HFAST loss predictions. Both codes require engine specific calibration to bring predictions and experimental data into agreement.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-09
... comparative visuals, and using vaguer language. This study is designed to apply the existing comparative... Effectiveness) studies designed to explore comparative effectiveness. When this large project is completed, FDA... Request; Experimental Study of Comparative Direct-to-Consumer Advertising AGENCY: Food and Drug...
ERIC Educational Resources Information Center
Martens, Brian K.; Eckert, Tanya L.; Bradley, Tracy A.; Ardoin, Scott P.
1999-01-01
Discusses the benefits of using brief experimental analysis to aid in treatment selection, identifies the forms of treatment that are most appropriate for this type of analysis, and describes key design elements for comparing treatments. Presents a study demonstrating the use of these design elements to identify an effective intervention for two…
Barlow, D H; Hayes, S C
1979-01-01
A little used and often confused design, capable of comparing two treatments within a single subject, has been termed, variously, a multielement baseline design, a multiple schedule design, and a randomization design. The background of these terms is reviewed, and a new, more descriptive term, Alternating Treatments Design, is proposed. Critical differences between this design and a Simultaneous Treatment Design are outlined, and experimental questions answerable by each design are noted. Potential problems with multiple treatment interference in this procedure are divided into sequential confounding, carryover effects, and alternation effects and the importance of these issues vis-a-vis other single-case experimental designs is considered. Methods of minimizing multiple treatment interference as well as methods of studying these effects are outlined. Finally, appropriate uses of Alternating Treatments Designs are described and discussed in the context of recent examples. PMID:489478
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-12
... that can demonstrate impact through other methodological approaches such as a quasi-experimental design... definition of ``relevant outcome.'' Lastly, quasi-experimental designs are already included in the definition... paragraph (b) of this definition, provided they are rigorous and comparable across schools. (b) For non...
Bajard, Agathe; Chabaud, Sylvie; Cornu, Catherine; Castellan, Anne-Charlotte; Malik, Salma; Kurbatova, Polina; Volpert, Vitaly; Eymard, Nathalie; Kassai, Behrouz; Nony, Patrice
2016-01-01
The main objective of our work was to compare different randomized clinical trial (RCT) experimental designs in terms of power, accuracy of the estimation of treatment effect, and number of patients receiving active treatment using in silico simulations. A virtual population of patients was simulated and randomized in potential clinical trials. Treatment effect was modeled using a dose-effect relation for quantitative or qualitative outcomes. Different experimental designs were considered, and performances between designs were compared. One thousand clinical trials were simulated for each design based on an example of modeled disease. According to simulation results, the number of patients needed to reach 80% power was 50 for crossover, 60 for parallel or randomized withdrawal, 65 for drop the loser (DL), and 70 for early escape or play the winner (PW). For a given sample size, each design had its own advantage: low duration (parallel, early escape), high statistical power and precision (crossover), and higher number of patients receiving the active treatment (PW and DL). Our approach can help to identify the best experimental design, population, and outcome for future RCTs. This may be particularly useful for drug development in rare diseases, theragnostic approaches, or personalized medicine. Copyright © 2016 Elsevier Inc. All rights reserved.
Slatter, P T
2001-01-01
The need for the design engineer to have a sound basis for designing sludge pumping and pipelining plant is becoming more critical. This paper examines both a traditional text-book approach and one of the latest approaches from the literature, and compares them with experimental data. The pipelining problem can be divided into the following main areas; rheological characterisation, laminar, transitional and turbulent flow and each is addressed in turn. Experimental data for a digested sludge tested in large pipes is analysed and compared with the two different theoretical approaches. Discussion is centred on the differences between the two methods and the degree of agreement with the data. It is concluded that the new approach has merit and can be used for practical design.
[Effects of foot reflexology on essential hypertension patients].
Park, Hyoung-Sook; Cho, Gyoo-Yeong
2004-08-01
This study was to evaluate the effects of foot reflexology on blood pressure, serum lipids level and life satisfaction in essential hypertension patients. The research design used was a nonequivalent control group pretest-posttest design. Foot Reflexology was used as the experimental treatment from June 23rd, 2003 until August 31st, 2003. Thirty-four subjects were assigned to an experimental group(18) and control group(16). Foot Reflexology was administered twice a week for 6 weeks and self foot Reflexology was administered twice a week for 4 weeks on the experimental group. There was a significant decrease in systolic blood pressure but no significant decrease in diastolic pressure in the experimental group compared to the control group. The total cholesterol level in the experimental group compared to the control group was not significantly decreased after foot reflexology. However, the triglyceride level in the experimental group compared to the control group was significantly decreased after foot reflexology. On the other hand, high density lipoprotein and low density lipoprotein levels in the experimental group compared to the control group was not significantly decreased after foot reflexology. Life satisfaction in the experimental group compared to the control group was significantly improved after foot reflexology. The results proved that foot reflexology was an effective nursing intervention to decrease systolic pressure, and triglyceride but not for the blood cholesterol and to improve life satisfaction. Therefore, blood cholesterol should be further evaluated in a larger group of subjects and for a longer period. Further research is regarded as necessary to evaluate and to compare effects of self-foot reflexology and foot reflexology.
Design and experimental results of the 1-T Bitter Electromagnet Testing Apparatus (BETA)
NASA Astrophysics Data System (ADS)
Bates, E. M.; Birmingham, W. J.; Romero-Talamás, C. A.
2018-05-01
The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) technical prototype of the 10 T Adjustable Long Pulsed High-Field Apparatus. BETA's final design specifications are highlighted in this paper which include electromagnetic, thermal, and stress analyses. We discuss here the design and fabrication of BETA's core, vessel, cooling, and electrical subsystems. The electrical system of BETA is composed of a scalable solid-state DC breaker circuit. Experimental results display the stable operation of BETA at 1 T. These results are compared to both analytical design and finite element calculations. Experimental results validate analytical magnet designing methods developed at the Dusty Plasma Laboratory. The theoretical steady state maxima and the limits of BETA's design are explored in this paper.
Design and experimental results of the 1-T Bitter Electromagnet Testing Apparatus (BETA).
Bates, E M; Birmingham, W J; Romero-Talamás, C A
2018-05-01
The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) technical prototype of the 10 T Adjustable Long Pulsed High-Field Apparatus. BETA's final design specifications are highlighted in this paper which include electromagnetic, thermal, and stress analyses. We discuss here the design and fabrication of BETA's core, vessel, cooling, and electrical subsystems. The electrical system of BETA is composed of a scalable solid-state DC breaker circuit. Experimental results display the stable operation of BETA at 1 T. These results are compared to both analytical design and finite element calculations. Experimental results validate analytical magnet designing methods developed at the Dusty Plasma Laboratory. The theoretical steady state maxima and the limits of BETA's design are explored in this paper.
USDA-ARS?s Scientific Manuscript database
Controlling for spatial variability is important in high-throughput phenotyping studies that enable large numbers of genotypes to be evaluated across time and space. In the current study, we compared the efficacy of different experimental designs and spatial models in the analysis of canopy spectral...
Collins, Linda M.; Dziak, John J.; Li, Runze
2009-01-01
An investigator who plans to conduct experiments with multiple independent variables must decide whether to use a complete or reduced factorial design. This article advocates a resource management perspective on making this decision, in which the investigator seeks a strategic balance between service to scientific objectives and economy. Considerations in making design decisions include whether research questions are framed as main effects or simple effects; whether and which effects are aliased (confounded) in a particular design; the number of experimental conditions that must be implemented in a particular design and the number of experimental subjects the design requires to maintain the desired level of statistical power; and the costs associated with implementing experimental conditions and obtaining experimental subjects. In this article four design options are compared: complete factorial, individual experiments, single factor, and fractional factorial designs. Complete and fractional factorial designs and single factor designs are generally more economical than conducting individual experiments on each factor. Although relatively unfamiliar to behavioral scientists, fractional factorial designs merit serious consideration because of their economy and versatility. PMID:19719358
Considering RNAi experimental design in parasitic helminths.
Dalzell, Johnathan J; Warnock, Neil D; McVeigh, Paul; Marks, Nikki J; Mousley, Angela; Atkinson, Louise; Maule, Aaron G
2012-04-01
Almost a decade has passed since the first report of RNA interference (RNAi) in a parasitic helminth. Whilst much progress has been made with RNAi informing gene function studies in disparate nematode and flatworm parasites, substantial and seemingly prohibitive difficulties have been encountered in some species, hindering progress. An appraisal of current practices, trends and ideals of RNAi experimental design in parasitic helminths is both timely and necessary for a number of reasons: firstly, the increasing availability of parasitic helminth genome/transcriptome resources means there is a growing need for gene function tools such as RNAi; secondly, fundamental differences and unique challenges exist for parasite species which do not apply to model organisms; thirdly, the inherent variation in experimental design, and reported difficulties with reproducibility undermine confidence. Ideally, RNAi studies of gene function should adopt standardised experimental design to aid reproducibility, interpretation and comparative analyses. Although the huge variations in parasite biology and experimental endpoints make RNAi experimental design standardization difficult or impractical, we must strive to validate RNAi experimentation in helminth parasites. To aid this process we identify multiple approaches to RNAi experimental validation and highlight those which we deem to be critical for gene function studies in helminth parasites.
Dylla, Daniel P.; Megison, Susan D.
2015-01-01
Objective. We compared the precision of a search strategy designed specifically to retrieve randomized controlled trials (RCTs) and systematic reviews of RCTs with search strategies designed for broader purposes. Methods. We designed an experimental search strategy that automatically revised searches up to five times by using increasingly restrictive queries as long at least 50 citations were retrieved. We compared the ability of the experimental and alternative strategies to retrieve studies relevant to 312 test questions. The primary outcome, search precision, was defined for each strategy as the proportion of relevant, high quality citations among the first 50 citations retrieved. Results. The experimental strategy had the highest median precision (5.5%; interquartile range [IQR]: 0%–12%) followed by the narrow strategy of the PubMed Clinical Queries (4.0%; IQR: 0%–10%). The experimental strategy found the most high quality citations (median 2; IQR: 0–6) and was the strategy most likely to find at least one high quality citation (73% of searches; 95% confidence interval 68%–78%). All comparisons were statistically significant. Conclusions. The experimental strategy performed the best in all outcomes although all strategies had low precision. PMID:25922798
DOT National Transportation Integrated Search
1974-01-01
Deflection tests conducted during the construction and shortly after the completion of a large experimental pavement project are reported. Four different pavement designs, as follows, are compared: 1. 6-inch cement stabilized subgrade, 6-inch crushed...
Multiple Measures of Juvenile Drug Court Effectiveness: Results of a Quasi-Experimental Design
ERIC Educational Resources Information Center
Rodriguez, Nancy; Webb, Vincent J.
2004-01-01
Prior studies of juvenile drug courts have been constrained by small samples, inadequate comparison groups, or limited outcome measures. The authors report on a 3-year evaluation that examines the impact of juvenile drug court participation on recidivism and drug use. A quasi-experimental design is used to compare juveniles assigned to drug court…
ERIC Educational Resources Information Center
Walker, Andrew; Recker, Mimi; Ye, Lei; Robertshaw, M. Brooke; Sellers, Linda; Leary, Heather
2012-01-01
This article presents a quasi-experimental study comparing the impact of two technology-related teacher professional development (TTPD) designs, aimed at helping junior high school science and mathematics teachers design online activities using the rapidly growing set of online learning resources available on the Internet. The first TTPD design…
Effects of experimental design on calibration curve precision in routine analysis
Pimentel, Maria Fernanda; Neto, Benício de Barros; Saldanha, Teresa Cristina B.
1998-01-01
A computational program which compares the effciencies of different experimental designs with those of maximum precision (D-optimized designs) is described. The program produces confidence interval plots for a calibration curve and provides information about the number of standard solutions, concentration levels and suitable concentration ranges to achieve an optimum calibration. Some examples of the application of this novel computational program are given, using both simulated and real data. PMID:18924816
Parallel Treatments Design: A Nested Single Subject Design for Comparing Instructional Procedures.
ERIC Educational Resources Information Center
Gast, David L.; Wolery, Mark
1988-01-01
This paper describes the parallel treatments design, a nested single subject experimental design that combines two concurrently implemented multiple probe designs, allows control for effects of extraneous variables through counterbalancing, and replicates its effects across behaviors. Procedural guidelines for the design's use and issues related…
Fulian; Gooch; Fisher; Stevens; Compton
2000-08-01
The development and application of a new electrochemical device using a computer-aided design strategy is reported. This novel design is based on the flow of electrolyte solution past a microwire electrode situated centrally within a large duct. In the design stage, finite element simulations were employed to evaluate feasible working geometries and mass transport rates. The computer-optimized designs were then exploited to construct experimental devices. Steady-state voltammetric measurements were performed for a reversible one-electron-transfer reaction to establish the experimental relationship between electrolysis current and solution velocity. The experimental results are compared to those predicted numerically, and good agreement is found. The numerical studies are also used to establish an empirical relationship between the mass transport limited current and the volume flow rate, providing a simple and quantitative alternative for workers who would prefer to exploit this device without the need to develop the numerical aspects.
NASA Technical Reports Server (NTRS)
Koch, L. Danielle
1998-01-01
Reported here is a design study of a propeller for a vehicle capable of subsonic flight in Earth's stratosphere. All propellers presented were required to absorb 63.4 kW (85 hp) at 25.9 km (85,000 ft) while aircraft cruise velocity was maintained at Mach 0.40. To produce the final design, classic momentum and blade-element theories were combined with two and three-dimensional results from the Advanced Ducted Propfan Analysis Code (ADPAC), a numerical Navier-Stokes analysis code. The Eppler 387 airfoil was used for each of the constant section propeller designs compared. Experimental data from the Langley Low-Turbulence Pressure Tunnel was used in the strip theory design and analysis programs written. The experimental data was also used to validate ADPAC at a Reynolds numbers of 60,000 and a Mach number of 0.20. Experimental and calculated surface pressure coefficients are compared for a range of angles of attack. Since low Reynolds number transonic experimental data was unavailable, ADPAC was used to generate two-dimensional section performance predictions for Reynolds numbers of 60,000 and 100,000 and Mach numbers ranging from 0.45 to 0.75. Surface pressure coefficients are presented for selected angles of attack. in addition to the variation of lift and drag coefficients at each flow condition. A three-dimensional model of the final design was made which ADPAC used to calculated propeller performance. ADPAC performance predictions were compared with strip-theory calculations at design point. Propeller efficiency predicted by ADPAC was within 1.5% of that calculated by strip theory methods, although ADPAC predictions of thrust, power, and torque coefficients were approximately 5% lower than the strip theory results. Simplifying assumptions made in the strip theory account for the differences seen.
Basheer Ahamed, Shadir Bughari; Vanajassun, Purushothaman Pranav; Rajkumar, Kothandaraman; Mahalaxmi, Sekar
2018-04-01
Single cross-sectional nickel-titanium (NiTi) rotary instruments during continuous rotations are subjected to constant and variable stresses depending on the canal anatomy. This study was intended to create 2 new experimental, theoretic single-file designs with combinations of triple U (TU), triangle (TR), and convex triangle (CT) cross sections and to compare their bending stresses in simulated root canals with a single cross-sectional instrument using finite element analysis. A 3-dimensional model of the simulated root canal with 45° curvature and NiTi files with 5 cross-sectional designs were created using Pro/ENGINEER Wildfire 4.0 software (PTC Inc, Needham, MA) and ANSYS software (version 17; ANSYS, Inc, Canonsburg, PA) for finite element analysis. The NiTi files of 3 groups had single cross-sectional shapes of CT, TR, and TU designs, and 2 experimental groups had a CT, TR, and TU (CTU) design and a TU, TR, and CT (UTC) design. The file was rotated in simulated root canals to analyze the bending stress, and the von Mises stress value for every file was recorded in MPa. Statistical analysis was performed using the Kruskal-Wallis test and the Bonferroni-adjusted Mann-Whitney test for multiple pair-wise comparison with a P value <.05 (95 %). The maximum bending stress of the rotary file was observed in the apical third of the CT design, whereas comparatively less stress was recorded in the CTU design. The TU and TR designs showed a similar stress pattern at the curvature, whereas the UTC design showed greater stress in the apical and middle thirds of the file in curved canals. All the file designs showed a statistically significant difference. The CTU designed instruments showed the least bending stress on a 45° angulated simulated root canal when compared with all the other tested designs. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Comparative efficacy of two battery-powered toothbrushes on dental plaque removal.
Ruhlman, C Douglas; Bartizek, Robert D; Biesbrock, Aaron R
2002-01-01
A number of clinical studies have consistently demonstrated that power toothbrushes deliver superior plaque removal compared to manual toothbrushes. Recently, a new power toothbrush (Crest SpinBrush) has been marketed with a design that fundamentally differs from other marketed power toothbrushes. Other power toothbrushes feature a small, round head designed to oscillate for enhanced cleaning between the teeth and below the gumline. The new power toothbrush incorporates a similar round oscillating head in conjunction with fixed bristles, which allows the user to brush with optimal manual brushing technique. The objective of this randomized, examiner-blind, parallel design study was to compare the plaque removal efficacy of a positive control power toothbrush (Colgate Actibrush) to an experimental toothbrush (Crest SpinBrush) following a single use among 59 subjects. Baseline plaque scores were 1.64 and 1.40 for the experimental toothbrush and control toothbrush treatment groups, respectively. With regard to all surfaces examined, the experimental toothbrush delivered an adjusted (via analysis of covariance) mean difference between baseline and post-brushing plaque scores of 0.47, while the control toothbrush delivered an adjusted mean difference of 0.33. On average, the difference between toothbrushes was statistically significant (p = 0.013). Because the covariate slope for the experimental group was statistically significantly greater (p = 0.001) than the slope for the control group, a separate slope model was used. Further analysis demonstrated that the experimental group had statistically significantly greater plaque removal than the control group for baseline plaque scores above 1.43. With respect to buccal surfaces, using a separate slope analysis of covariance, the experimental toothbrush delivered an adjusted mean difference between baseline and post-brushing plaque scores of 0.61, while the control toothbrush delivered an adjusted mean difference of 0.39. This difference between toothbrushes was also statistically significant (p = 0.002). On average, the results on lingual surfaces demonstrated similar directional scores favoring the experimental toothbrush; however these results did not achieve statistical significance. In conclusion, the experimental Crest SpinBrush, with its novel fixed and oscillating bristle design, was found to be more effective than the positive control Colgate Actibrush, which is designed with a small round oscillating cluster of bristles.
ERIC Educational Resources Information Center
Liu, Yuliang
2013-01-01
This quasi-experimental study was to design, develop, and implement one multimedia math lesson in third grade to improve students' math learning. The non-equivalent control group design was used. The experimental group had 11 third grade students and the control group had 15 third grade students in an African American predominated elementary…
Instructional Coaching at Selected Middle Schools in South Texas and Effects on Student Achievement
ERIC Educational Resources Information Center
Garcia, SantaPaula Gama; Jones, Don; Holland, Glenda; Mundy, Marie-Anne
2013-01-01
The purpose of this study was to compare two middle schools in one school district in south Texas to determine if presence or absence of instructional coaches has an effect on student achievement. The research design was a quantitative pre experimental study: a nonequivalent (posttest only) control group design in which the experimental group and…
Off-design performance loss model for radial turbines with pivoting, variable-area stators
NASA Technical Reports Server (NTRS)
Meitner, P. L.; Glassman, A. J.
1980-01-01
An off-design performance loss model was developed for variable stator (pivoted vane), radial turbines through analytical modeling and experimental data analysis. Stator loss is determined by a viscous loss model; stator vane end-clearance leakage effects are determined by a clearance flow model. Rotor loss coefficient were obtained by analyzing the experimental data from a turbine rotor previously tested with six stators having throat areas from 20 to 144 percent of design area and were correlated with stator-to-rotor throat area ratio. An incidence loss model was selected to obtain best agreement with experimental results. Predicted turbine performance is compared with experimental results for the design rotor as well as with results for extended and cutback versions of the rotor. Sample calculations were made to show the effects of stator vane end-clearance leakage.
Comparing Pedagogies for Plastic Waste Management at University Level
ERIC Educational Resources Information Center
Yeung, Siu-Kit; So, Wing-Mui Winnie; Cheng, Nga-Yee Irene; Cheung, Tsz-Yan; Chow, Cheuk-Fai
2017-01-01
Purpose: This paper aims to compare the learning outcomes of gaming simulation and guided inquiry in sustainability education on plastic waste management. The current study targets the identification of success factors in these teaching approaches. Design/methodology/approach: This study used a quasi-experimental design with undergraduate…
Assessing Pupils' Skills in Experimentation
ERIC Educational Resources Information Center
Hammann, Marcus; Phan, Thi Thanh Hoi; Ehmer, Maike; Grimm, Tobias
2008-01-01
This study is concerned with different forms of assessment of pupils' skills in experimentation. The findings of three studies are reported. Study 1 investigates whether it is possible to develop reliable multiple-choice tests for the skills of forming hypotheses, designing experiments and analysing experimental data. Study 2 compares scores from…
Counselor Effectiveness Through Radio Communication.
ERIC Educational Resources Information Center
Tentoni, Stuart C.
This study determined the effectiveness of the use of radio as a means of providing immediate feedback on student counselors in a practicum setting. Using a non-equivalent group experimental design, 10 experimental subjects were compared to 10 control subjects with respect to counselor effectiveness. The experimental subjects were given immediate…
Design and Experimental Study on Spinning Solid Rocket Motor
NASA Astrophysics Data System (ADS)
Xue, Heng; Jiang, Chunlan; Wang, Zaicheng
The study on spinning solid rocket motor (SRM) which used as power plant of twice throwing structure of aerial submunition was introduced. This kind of SRM which with the structure of tangential multi-nozzle consists of a combustion chamber, propellant charge, 4 tangential nozzles, ignition device, etc. Grain design, structure design and prediction of interior ballistic performance were described, and problem which need mainly considered in design were analyzed comprehensively. Finally, in order to research working performance of the SRM, measure pressure-time curve and its speed, static test and dynamic test were conducted respectively. And then calculated values and experimental data were compared and analyzed. The results indicate that the designed motor operates normally, and the stable performance of interior ballistic meet demands. And experimental results have the guidance meaning for the pre-research design of SRM.
76 FR 30926 - Notice of Proposed Information Collection Requests
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-27
... North Carolina study will use a quasi-experimental design using propensity score matching. State end-of... student learning will be compared to a traditional FLVS U.S. History online course using an experimental...
A Single-Vector Force Calibration Method Featuring the Modern Design of Experiments
NASA Technical Reports Server (NTRS)
Parker, P. A.; Morton, M.; Draper, N.; Line, W.
2001-01-01
This paper proposes a new concept in force balance calibration. An overview of the state-of-the-art in force balance calibration is provided with emphasis on both the load application system and the experimental design philosophy. Limitations of current systems are detailed in the areas of data quality and productivity. A unique calibration loading system integrated with formal experimental design techniques has been developed and designated as the Single-Vector Balance Calibration System (SVS). This new concept addresses the limitations of current systems. The development of a quadratic and cubic calibration design is presented. Results from experimental testing are compared and contrasted with conventional calibration systems. Analyses of data are provided that demonstrate the feasibility of this concept and provide new insights into balance calibration.
Alsaggaf, Rotana; O'Hara, Lyndsay M; Stafford, Kristen A; Leekha, Surbhi; Harris, Anthony D
2018-02-01
OBJECTIVE A systematic review of quasi-experimental studies in the field of infectious diseases was published in 2005. The aim of this study was to assess improvements in the design and reporting of quasi-experiments 10 years after the initial review. We also aimed to report the statistical methods used to analyze quasi-experimental data. DESIGN Systematic review of articles published from January 1, 2013, to December 31, 2014, in 4 major infectious disease journals. METHODS Quasi-experimental studies focused on infection control and antibiotic resistance were identified and classified based on 4 criteria: (1) type of quasi-experimental design used, (2) justification of the use of the design, (3) use of correct nomenclature to describe the design, and (4) statistical methods used. RESULTS Of 2,600 articles, 173 (7%) featured a quasi-experimental design, compared to 73 of 2,320 articles (3%) in the previous review (P<.01). Moreover, 21 articles (12%) utilized a study design with a control group; 6 (3.5%) justified the use of a quasi-experimental design; and 68 (39%) identified their design using the correct nomenclature. In addition, 2-group statistical tests were used in 75 studies (43%); 58 studies (34%) used standard regression analysis; 18 (10%) used segmented regression analysis; 7 (4%) used standard time-series analysis; 5 (3%) used segmented time-series analysis; and 10 (6%) did not utilize statistical methods for comparisons. CONCLUSIONS While some progress occurred over the decade, it is crucial to continue improving the design and reporting of quasi-experimental studies in the fields of infection control and antibiotic resistance to better evaluate the effectiveness of important interventions. Infect Control Hosp Epidemiol 2018;39:170-176.
An experimental and theoretical study of structural damping in compliant foil bearings
NASA Technical Reports Server (NTRS)
Ku, C.-P. Roger
1994-01-01
This paper describes an experimental investigation into the dynamic characteristics of corrugated foil (bump foil) strips used in compliant surface foil bearings. This study provided and opportunity to quantify the structural damping of bump foil strips. The experimental data were compared to results obtained by a theoretical model developed earlier. The effects of bearing design parameters, such as static loads, dynamic displacement amplitudes, bump configurations, pivot locations, surface coatings, and lubricant were also evaluated. An understanding of the dynamic characteristics of bump foil strips resulting from this work offers designers a means for enhancing the design of high-performance compliant foil bearings.
ERIC Educational Resources Information Center
Price, Cristofer; Unlu, Fatih
2014-01-01
The Comparative Short Interrupted Time Series (C-SITS) design is a frequently employed quasi-experimental method, in which the pre- and post-intervention changes observed in the outcome levels of a treatment group is compared with those of a comparison group where the difference between the former and the latter is attributed to the treatment. The…
NASA Astrophysics Data System (ADS)
Marulcu, Ismail; Barnett, Michael
2016-01-01
Background: Elementary Science Education is struggling with multiple challenges. National and State test results confirm the need for deeper understanding in elementary science education. Moreover, national policy statements and researchers call for increased exposure to engineering and technology in elementary science education. The basic motivation of this study is to suggest a solution to both improving elementary science education and increasing exposure to engineering and technology in it. Purpose/Hypothesis: This mixed-method study examined the impact of an engineering design-based curriculum compared to an inquiry-based curriculum on fifth graders' content learning of simple machines. We hypothesize that the LEGO-engineering design unit is as successful as the inquiry-based unit in terms of students' science content learning of simple machines. Design/Method: We used a mixed-methods approach to investigate our research questions; we compared the control and the experimental groups' scores from the tests and interviews by using Analysis of Covariance (ANCOVA) and compared each group's pre- and post-scores by using paired t-tests. Results: Our findings from the paired t-tests show that both the experimental and comparison groups significantly improved their scores from the pre-test to post-test on the multiple-choice, open-ended, and interview items. Moreover, ANCOVA results show that students in the experimental group, who learned simple machines with the design-based unit, performed significantly better on the interview questions. Conclusions: Our analyses revealed that the design-based Design a people mover: Simple machines unit was, if not better, as successful as the inquiry-based FOSS Levers and pulleys unit in terms of students' science content learning.
NASA Technical Reports Server (NTRS)
Harris, C. D.
1975-01-01
This report documents the experimental aerodynamic characteristics of a 14 percent thick supercritical airfoil based on an off design sonic pressure plateau criterion. The design normal force coefficient was 0.7. The results are compared with those of the family related 10 percent thick supercritical airfoil 33. Comparisons are also made between experimental and theoretical characteristics and composite drag rise characteristics derived for a full scale Reynolds number of 40 million.
ERIC Educational Resources Information Center
Varnell, Matt
2013-01-01
The purpose of this study was to evaluate the effect of rhythm and tonality on an academic memory task by comparing three different treatment conditions: a poem, a rhythmic chant (or rap), and a melodic rhythm (or song). A quasi-experimental experiment was designed and implemented, specifically a pretest-posttest-posttest control-group design.…
Louisiana experimental base project : interim report No. 1.
DOT National Transportation Integrated Search
1979-11-01
The Louisiana Experimental Base Project is a research study evaluating the design/performance characteristics of three types of base courses as incorporated into comparable flexible pavement systems on a full-scale test road. Fourteen different test ...
Uhm, Dong-choon
2010-08-01
The purpose of this study was to evaluate the effects on immigrant couples' communication, intimacy, conflict and quality of life when using foot massage. The research design consisted of pre-and-post test consecutive experimental design through a nonequivalent control group. Data were collected July 6, 2009 to February 27, 2010. The 36 couples were divided into two groups, experimental and control with 18 couples in each group. Foot massage was applied twice a week for 6 weeks by the couples in the experimental group. There were statistically significant increases in communication (p=.011), intimacy (p<.001), quality of life (p=.017) between the couples in the experimental group compared to the control group. There was also a statistically significant decrease in conflict (p=.003) between the couples in the experimental group compared to the control group. Foot massage can be applied as a nursing intervention for improvement of marital relationship in immigrant couples.
ERIC Educational Resources Information Center
Chen, Mo; Hyppa-Martin, Jolene K.; Reichle, Joe E.; Symons, Frank J.
2016-01-01
Meaningfully synthesizing single case experimental data from intervention studies comprised of individuals with low incidence conditions and generating effect size estimates remains challenging. Seven effect size metrics were compared for single case design (SCD) data focused on teaching speech generating device use to individuals with…
Design and experimental evaluation of robust controllers for a two-wheeled robot
NASA Astrophysics Data System (ADS)
Kralev, J.; Slavov, Ts.; Petkov, P.
2016-11-01
The paper presents the design and experimental evaluation of two alternative μ-controllers for robust vertical stabilisation of a two-wheeled self-balancing robot. The controllers design is based on models derived by identification from closed-loop experimental data. In the first design, a signal-based uncertainty representation obtained directly from the identification procedure is used, which leads to a controller of order 29. In the second design the signal uncertainty is approximated by an input multiplicative uncertainty, which leads to a controller of order 50, subsequently reduced to 30. The performance of the two μ-controllers is compared with the performance of a conventional linear quadratic controller with 17th-order Kalman filter. A proportional-integral controller of the rotational motion around the vertical axis is implemented as well. The control code is generated using Simulink® controller models and is embedded in a digital signal processor. Results from the simulation of the closed-loop system as well as experimental results obtained during the real-time implementation of the designed controllers are given. The theoretical investigation and experimental results confirm that the closed-loop system achieves robust performance in respect to the uncertainties related to the identified robot model.
Experimental comparison of inquiry and direct instruction in science
NASA Astrophysics Data System (ADS)
Cobern, William W.; Schuster, David; Adams, Betty; Applegate, Brooks; Skjold, Brandy; Undreiu, Adriana; Loving, Cathleen C.; Gobert, Janice D.
2010-04-01
There are continuing educational and political debates about 'inquiry' versus 'direct' teaching of science. Traditional science instruction has been largely direct but in the US, recent national and state science education standards advocate inquiry throughout K-12 education. While inquiry-based instruction has the advantage of modelling aspects of the nature of real scientific inquiry, there is little unconfounded comparative research into the effectiveness and efficiency of the two instructional modes for developing science conceptual understanding. This research undertook a controlled experimental study comparing the efficacy of carefully designed inquiry instruction and equally carefully designed direct instruction in realistic science classroom situations at the middle school grades. The research design addressed common threats to validity. We report on the nature of the instructional units in each mode, research design, methods, classroom implementations, monitoring, assessments, analysis and project findings.
Comparison of a quasi-3D analysis and experimental performance for three compact radial turbines
NASA Technical Reports Server (NTRS)
Simonyi, P. S.; Boyle, R. J.
1991-01-01
An experimental aerodynamic evaluation of three compact radial turbine builds was performed. Two rotors which were 40-50 percent shorter in axial length than conventional state-of-the-art radial rotors were tested. A single nozzle design was used. One rotor was tested with the nozzle at two stagger angle settings. A second rotor was tested with the nozzle in only the closed down setting. Experimental results were compared to predicted results from a quasi-3D inviscid and boundary layer analysis, called MTSB (Meridl/Tsonic/Blayer). This analysis was used to predict turbine performance. It has previously been calibrated only for axial, not radial, turbomachinery. The predicted and measured efficiencies were compared at the design point for the three turbines. At the design points the analysis overpredicted the efficiency by less than 1.7 points. Comparisons were also made at off-design operating points. The results of these comparisons showed the importance of an accurate clearance model for efficiency predictions and also that there are deficiencies in the incidence loss model used.
Comparison of a quasi-3D analysis and experimental performance for three compact radial turbines
NASA Technical Reports Server (NTRS)
Simonyi, P. S.; Boyle, R. J.
1991-01-01
An experimental aerodynamic evaluation of three compact radial turbine builds was performed. Two rotors which were 40 to 50 percent shorter in axial length than conventional state of the art radial rotors were tested. A single nozzle design was used. One rotor was tested with the nozzle at two stagger angle settings. A second rotor was tested with the nozzle in only the closed down setting. Experimental results were compared to predict results from a quasi-3D inviscid and boundary layer analysis, called Meridl/Tsonic/Blayer (MTSB). This analysis was used to predict turbine performance. It has previously been calibrated only for axial, not radial, turbomachinery. The predicted and measured efficiencies were compared at the design point for the three turbines. At the design points the analysis overpredicted the efficiency by less than 1.7 points. Comparisons were also made at off-design operating points. The results of these comparisons showed the importance of an accurate clearance model for efficiency predictions and also that there are deficiencies in the incidence loss model used.
Theoretical and experimental researches of the liquid evaporation during thermal vacuum influences
NASA Astrophysics Data System (ADS)
Trushlyakov, V.; Panichkin, A.; Prusova, O.; Zharikov, K.; Dron, M.
2018-01-01
The mathematical model of the evaporation process of model liquid with the free surface boundary conditions of the "mirror" type under thermal vacuum influence and the numerical estimates of the evaporation process parameters are developed. An experimental stand, comprising a vacuum chamber, an experimental model tank with a heating element is designed; the experimental data are obtained. A comparative analysis of numerical and experimental results showed their close match.
Photonic Jets for Strained-Layer Superlattice Infrared Photodetector Enhancement
2014-06-25
top of a 40 µm photodetector fixed into position using a silicone rubber . As illustrated in Fig. 2, the spectral response was characterized before and...midwave-infrared spectral band (3-5 ?m). We optimized the design of these structures and experimentally demonstrated the increased sensitivity compared to...midwave-infrared spectral band (3-5 ?m). We optimized the design of these structures and experimentally demonstrated the increased sensitivity
Increasing efficiency of preclinical research by group sequential designs
Piper, Sophie K.; Rex, Andre; Florez-Vargas, Oscar; Karystianis, George; Schneider, Alice; Wellwood, Ian; Siegerink, Bob; Ioannidis, John P. A.; Kimmelman, Jonathan; Dirnagl, Ulrich
2017-01-01
Despite the potential benefits of sequential designs, studies evaluating treatments or experimental manipulations in preclinical experimental biomedicine almost exclusively use classical block designs. Our aim with this article is to bring the existing methodology of group sequential designs to the attention of researchers in the preclinical field and to clearly illustrate its potential utility. Group sequential designs can offer higher efficiency than traditional methods and are increasingly used in clinical trials. Using simulation of data, we demonstrate that group sequential designs have the potential to improve the efficiency of experimental studies, even when sample sizes are very small, as is currently prevalent in preclinical experimental biomedicine. When simulating data with a large effect size of d = 1 and a sample size of n = 18 per group, sequential frequentist analysis consumes in the long run only around 80% of the planned number of experimental units. In larger trials (n = 36 per group), additional stopping rules for futility lead to the saving of resources of up to 30% compared to block designs. We argue that these savings should be invested to increase sample sizes and hence power, since the currently underpowered experiments in preclinical biomedicine are a major threat to the value and predictiveness in this research domain. PMID:28282371
Shadish, William R; Rindskopf, David M; Boyajian, Jonathan G
2016-08-01
We reanalyzed data from a previous randomized crossover design that administered high or low doses of intravenous immunoglobulin (IgG) to 12 patients with hypogammaglobulinaemia over 12 time points, with crossover after time 6. The objective was to see if results corresponded when analyzed as a set of single-case experimental designs vs. as a usual randomized controlled trial (RCT). Two blinded statisticians independently analyzed results. One analyzed the RCT comparing mean outcomes of group A (high dose IgG) to group B (low dose IgG) at the usual trial end point (time 6 in this case). The other analyzed all 12 time points for the group B patients as six single-case experimental designs analyzed together in a Bayesian nonlinear framework. In the randomized trial, group A [M = 794.93; standard deviation (SD) = 90.48] had significantly higher serum IgG levels at time six than group B (M = 283.89; SD = 71.10) (t = 10.88; df = 10; P < 0.001), yielding a mean difference of MD = 511.05 [standard error (SE) = 46.98]. For the single-case experimental designs, the effect from an intrinsically nonlinear regression was also significant and comparable in size with overlapping confidence intervals: MD = 495.00, SE = 54.41, and t = 495.00/54.41 = 9.10. Subsequent exploratory analyses indicated that how trend was modeled made a difference to these conclusions. The results of single-case experimental designs accurately approximated results from an RCT, although more work is needed to understand the conditions under which this holds. Copyright © 2016 Elsevier Inc. All rights reserved.
76 FR 25674 - Notice of Submission for OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-05
... for the rigorous comparative interrupted time series design including student records data collection...- experimental designs to explore the relationship between magnet programs and student achievement both for... this study. An OMB clearance request that (1) described the study design and full data collection...
ERIC Educational Resources Information Center
Cattaneo, Matias D.; Titiunik, Rocío; Vazquez-Bare, Gonzalo
2017-01-01
The regression discontinuity (RD) design is a popular quasi-experimental design for causal inference and policy evaluation. The most common inference approaches in RD designs employ "flexible" parametric and nonparametric local polynomial methods, which rely on extrapolation and large-sample approximations of conditional expectations…
PopED lite: An optimal design software for preclinical pharmacokinetic and pharmacodynamic studies.
Aoki, Yasunori; Sundqvist, Monika; Hooker, Andrew C; Gennemark, Peter
2016-04-01
Optimal experimental design approaches are seldom used in preclinical drug discovery. The objective is to develop an optimal design software tool specifically designed for preclinical applications in order to increase the efficiency of drug discovery in vivo studies. Several realistic experimental design case studies were collected and many preclinical experimental teams were consulted to determine the design goal of the software tool. The tool obtains an optimized experimental design by solving a constrained optimization problem, where each experimental design is evaluated using some function of the Fisher Information Matrix. The software was implemented in C++ using the Qt framework to assure a responsive user-software interaction through a rich graphical user interface, and at the same time, achieving the desired computational speed. In addition, a discrete global optimization algorithm was developed and implemented. The software design goals were simplicity, speed and intuition. Based on these design goals, we have developed the publicly available software PopED lite (http://www.bluetree.me/PopED_lite). Optimization computation was on average, over 14 test problems, 30 times faster in PopED lite compared to an already existing optimal design software tool. PopED lite is now used in real drug discovery projects and a few of these case studies are presented in this paper. PopED lite is designed to be simple, fast and intuitive. Simple, to give many users access to basic optimal design calculations. Fast, to fit a short design-execution cycle and allow interactive experimental design (test one design, discuss proposed design, test another design, etc). Intuitive, so that the input to and output from the software tool can easily be understood by users without knowledge of the theory of optimal design. In this way, PopED lite is highly useful in practice and complements existing tools. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flathers, M.B.; Bache, G.E.; Rainsberger, R.
1996-04-01
The flow field of a complex three-dimensional radial inlet for an industrial pipeline centrifugal compressor has been experimentally determined on a half-scale model. Based on the experimental results, inlet guide vanes have been designed to correct pressure and swirl angle distribution deficiencies. The unvaned and vaned inlets are analyzed with a commercially available fully three-dimensional viscous Navier-Stokes code. Since experimental results were available prior to the numerical study, the unvaned analysis is considered a postdiction while the vaned analysis is considered a prediction. The computational results of the unvaned inlet have been compared to the previously obtained experimental results. Themore » experimental method utilized for the unvaned inlet is repeated for the vaned inlet and the data have been used to verify the computational results. The paper will discuss experimental, design, and computational procedures, grid generation, boundary conditions, and experimental versus computational methods. Agreement between experimental and computational results is very good, both in prediction and postdiction modes. The results of this investigation indicate that CFD offers a measurable advantage in design, schedule, and cost and can be applied to complex, three-dimensional radial inlets.« less
Experimental investigation of solid rocket motors for small sounding rockets
NASA Astrophysics Data System (ADS)
Suksila, Thada
2018-01-01
Experimentation and research of solid rocket motors are important subjects for aerospace engineering students. However, many institutes in Thailand rarely include experiments on solid rocket motors in research projects of aerospace engineering students, mainly because of the complexity of mixing the explosive propellants. This paper focuses on the design and construction of a solid rocket motor for total impulse in the class I-J that can be utilised as a small sounding rocket by researchers in the near future. Initially, the test stands intended for measuring the pressure in the combustion chamber and the thrust of the solid rocket motor were designed and constructed. The basic design of the propellant configuration was evaluated. Several formulas and ratios of solid propellants were compared for achieving the maximum thrust. The convenience of manufacturing and casting of the fabricated solid rocket motors were a critical consideration. The motor structural analysis such as the combustion chamber wall thickness was also discussed. Several types of nozzles were compared and evaluated for ensuring the maximum thrust of the solid rocket motors during the experiments. The theory of heat transfer analysis in the combustion chamber was discussed and compared with the experimental data.
Hand controller study of force and control mode
NASA Technical Reports Server (NTRS)
Morris, A. Terry
1992-01-01
The objectives are to compare and evaluate the utility and effectiveness of various input control devices, e.g., hand controllers, with respect to the relative importance of force and operation control mode (rate or position) for Space Station Freedom (SSF) related tasks. The topics are presented in viewgraph form and include the: Intelligent Research Systems Lab (ISRL) experimental design; Telerobotic Systems Research Laboratory (TSRL) final experimental design; and factor analysis summary of results.
Morton, Reeva C; Gadke, Daniel L
2018-03-01
Cover, Copy, Compare (CCC) and Copy, Cover, Compare (MCCC) procedures are effective interventions for improving math fluency. However, there is a gap in literature exploring the use of these interventions for children with autism spectrum disorders (ASD). The purpose of the current study was to compare the use of CCC and MCCC for children with ASD using a multi-component single-case experimental design. The results showed no notable difference between the interventions. Implications and limitations, particularly surrounding experimental control, are discussed in detail.
Effects of eccentricities and lateral pressure on the design of stiffened compression panels
NASA Technical Reports Server (NTRS)
Giles, G. L.; Anderson, M. S.
1972-01-01
An analysis for determining the effects of eccentricities and lateral pressure on the design of stiffened compression panels is presented. The four types of panel stiffeners considered are integral, zee, integral zee, and integral tee. Mass-strength curves, which give the mass of the panel necessary to carry a specified load, are given along with related design equations needed to calculate the cross-sectional dimensions of the minimum-mass-stiffened panel. The results of the study indicate that the proportions of the panels are geometrically similar to the proportions of panels designed for no eccentricity or lateral pressure, but no cross-sectional dimensions are greater, resulting in significantly increased mass. The analytical minimum-mass designs of zee-stiffened panels are compared with designs from experimentally derived charts. An assumed eccentricity of 0.001 times the length of the panel is used to correlate the analytical and experimental data. Good correlation between the experimentally derived and the analytical curves is obtained for the range of loading where materials yield governs the design. At lower loads the mass given by the analytical curve using this assumed eccentricity is greater than that given by the experimental results.
Yoo, Yang Sook; Cho, Ok Hee; Kim, Eun Sin; Jeong, Hye Sun
2005-06-01
This study was designed to examine the effect of asthma management education program applied to allergic asthma patients receiving immunotherapy due to house dust mite on their stress and compliance with health care regimens. A quasi experimental design with non-equivalent control group and non-synchronized design was used. The subjects of this study were 61 patients who were receiving immunotherapy at intervals of a week after their symptoms were diagnosed as house dust mite allergic asthma at the pulmonary department of a university hospital in Seoul. They were divided into an experimental group of 29 patients who received asthma management education and a control group of 32 patients. The asthma management education program was composed of group education (once) and reinforcement education (three times) with environmental therapy and immunotherapy to house dust mite. Stress significantly decreased in the experimental group compared to that in the control group. Compliance with health care regimens significantly increased in the experimental group compared to that in the control group. The results suggested that the asthma management education program is effective for the management of stress and the improvement of compliance in patients with allergic asthma to house dust mite.
Van Daele, Timothy; Gernaey, Krist V; Ringborg, Rolf H; Börner, Tim; Heintz, Søren; Van Hauwermeiren, Daan; Grey, Carl; Krühne, Ulrich; Adlercreutz, Patrick; Nopens, Ingmar
2017-09-01
The aim of model calibration is to estimate unique parameter values from available experimental data, here applied to a biocatalytic process. The traditional approach of first gathering data followed by performing a model calibration is inefficient, since the information gathered during experimentation is not actively used to optimize the experimental design. By applying an iterative robust model-based optimal experimental design, the limited amount of data collected is used to design additional informative experiments. The algorithm is used here to calibrate the initial reaction rate of an ω-transaminase catalyzed reaction in a more accurate way. The parameter confidence region estimated from the Fisher Information Matrix is compared with the likelihood confidence region, which is not only more accurate but also a computationally more expensive method. As a result, an important deviation between both approaches is found, confirming that linearization methods should be applied with care for nonlinear models. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:1278-1293, 2017. © 2017 American Institute of Chemical Engineers.
The experimental and calculated characteristics of 22 tapered wings
NASA Technical Reports Server (NTRS)
Anderson, Raymond F
1938-01-01
The experimental and calculated aerodynamic characteristics of 22 tapered wings are compared, using tests made in the variable-density wind tunnel. The wings had aspect ratios from 6 to 12 and taper ratios from 1:6:1 and 5:1. The compared characteristics are the pitching moment, the aerodynamic-center position, the lift-curve slope, the maximum lift coefficient, and the curves of drag. The method of obtaining the calculated values is based on the use of wing theory and experimentally determined airfoil section data. In general, the experimental and calculated characteristics are in sufficiently good agreement that the method may be applied to many problems of airplane design.
ERIC Educational Resources Information Center
Kroeker, Leonard P.
The problem of blocking on a status variable was investigated. The one-way fixed-effects analysis of variance, analysis of covariance, and generalized randomized block designs each treat the blocking problem in a different way. In order to compare these designs, it is necessary to restrict attention to experimental situations in which observations…
Experimental investigation of reinforced bonded joints for composite laminates.
Bisagni, Chiara; Furfari, Domenico; Pacchione, Marco
2018-02-01
An experimental study has been carried out to investigate the behaviour of co-bonded carbon fibre reinforced plastics joints with a novel design incorporating a through the thickness local reinforcement. Different specimens were manufactured to investigate static and fatigue behaviour, as well as delamination size after impact and damage tolerance characteristics. The mechanical performances of the specimens with local reinforcement, consisting of the insertion of spiked thin metal sheets between co-bonded laminates, were compared with those ones obtained from specimens with purely co-bonded joints. This novel design demonstrated by tests that damage progression under cycling load results significantly delayed by the reinforcements. A significant number of experimental results were obtained that can be used to define preliminary design guidelines.
Experimental investigation of reinforced bonded joints for composite laminates
Bisagni, Chiara; Furfari, Domenico; Pacchione, Marco
2017-01-01
An experimental study has been carried out to investigate the behaviour of co-bonded carbon fibre reinforced plastics joints with a novel design incorporating a through the thickness local reinforcement. Different specimens were manufactured to investigate static and fatigue behaviour, as well as delamination size after impact and damage tolerance characteristics. The mechanical performances of the specimens with local reinforcement, consisting of the insertion of spiked thin metal sheets between co-bonded laminates, were compared with those ones obtained from specimens with purely co-bonded joints. This novel design demonstrated by tests that damage progression under cycling load results significantly delayed by the reinforcements. A significant number of experimental results were obtained that can be used to define preliminary design guidelines. PMID:29568127
NASA Technical Reports Server (NTRS)
Brent, J. A.; Cheatham, J. G.; Clemmons, D. R.
1972-01-01
A conventional and a tandem bladed stage were designed for a comparative experimental evaluation in a 0.8 hub/tip ratio single-stage compressor. Based on a preliminary design study, a radially constant work input distribution was selected for the rotor designs. Velocity diagrams and blade leading and trailing edge angles selected for the conventional rotor and stator were used in the design of the tandem blading. The effects of axial velocity ratio and secondary flow on turning were included in the selection of blade leading and trailing edge angles. Design values of rotor tip velocity and stage pressure ratio were 757 ft/sec and 1.26, respectively.
Reverse design and characteristic study of multi-range HMCVT
NASA Astrophysics Data System (ADS)
Zhu, Zhen; Chen, Long; Zeng, Falin
2017-09-01
The reduction of fuel consumption and increase of transmission efficiency is one of the key problems of the agricultural machinery. Many promising technologies such as hydromechanical continuously variable transmissions (HMCVT) are the focus of research and investments, but there is little technical documentation that describes the design principle and presents the design parameters. This paper presents the design idea and characteristic study of HMCVT, in order to find out the suitable scheme for the big horsepower tractors. Analyzed the kinematics and dynamics of a large horsepower tractor, according to the characteristic parameters, a hydro-mechanical continuously variable transmission has been designed. Compared with the experimental curves and theoretical curves of the stepless speed regulation of transmission, the experimental result illustrates the rationality of the design scheme.
Effects of large woody debris placement on stream channels and benthic macroinvertebrates
Robert H. Hilderbrand; A. Dennis Lemly; C. Andrew Dolloff; Kelly L. Harpster
1997-01-01
Large woody debris (LWD)was added as an experimental stream restoration techniquein two streams in southwest Virginia. Additions were designed to compare human judgement in log placements against a randomized design and an unmanipulated reach, &d also to compare effectiveness in a low- and a high-gradient stream. Pool area increased 146% in the systematic placement...
ERIC Educational Resources Information Center
Wilkerson, Kevin; Perusse, Rachelle; Hughes, Ashley
2013-01-01
This study compares school-wide Annual Yearly Progress (AYP) results in Indiana schools earning the Recognized ASCA Model Program (RAMP) designation (n = 75) with a sample of control schools stratified by level and locale (n = 226). K-12 schools earning the RAMP designation in 2007, 2008, and 2009 comprise the experimental group. Findings indicate…
NASA Technical Reports Server (NTRS)
Perchonok, Michele; Antonini, David
2008-01-01
This viewgraph presentation describes a comparative packaging study for use on long duration space missions. The topics include: 1) Purpose; 2) Deliverables; 3) Food Sample Selection; 4) Experimental Design Matrix; 5) Permeation Rate Comparison; and 6) Packaging Material Information.
Analytical and scale model research aimed at improved hangglider design
NASA Technical Reports Server (NTRS)
Kroo, I.; Chang, L. S.
1979-01-01
Research consisted of a theoretical analysis which attempts to predict aerodynamic characteristics using lifting surface theory and finite-element structural analysis as well as an experimental investigation using 1/5 scale elastically similar models in the NASA Ames 2m x 3m (7' x 10') wind tunnel. Experimental data were compared with theoretical results in the development of a computer program which may be used in the design and evaluation of ultralight gliders.
Reed Johnson, F; Lancsar, Emily; Marshall, Deborah; Kilambi, Vikram; Mühlbacher, Axel; Regier, Dean A; Bresnahan, Brian W; Kanninen, Barbara; Bridges, John F P
2013-01-01
Stated-preference methods are a class of evaluation techniques for studying the preferences of patients and other stakeholders. While these methods span a variety of techniques, conjoint-analysis methods-and particularly discrete-choice experiments (DCEs)-have become the most frequently applied approach in health care in recent years. Experimental design is an important stage in the development of such methods, but establishing a consensus on standards is hampered by lack of understanding of available techniques and software. This report builds on the previous ISPOR Conjoint Analysis Task Force Report: Conjoint Analysis Applications in Health-A Checklist: A Report of the ISPOR Good Research Practices for Conjoint Analysis Task Force. This report aims to assist researchers specifically in evaluating alternative approaches to experimental design, a difficult and important element of successful DCEs. While this report does not endorse any specific approach, it does provide a guide for choosing an approach that is appropriate for a particular study. In particular, it provides an overview of the role of experimental designs for the successful implementation of the DCE approach in health care studies, and it provides researchers with an introduction to constructing experimental designs on the basis of study objectives and the statistical model researchers have selected for the study. The report outlines the theoretical requirements for designs that identify choice-model preference parameters and summarizes and compares a number of available approaches for constructing experimental designs. The task-force leadership group met via bimonthly teleconferences and in person at ISPOR meetings in the United States and Europe. An international group of experimental-design experts was consulted during this process to discuss existing approaches for experimental design and to review the task force's draft reports. In addition, ISPOR members contributed to developing a consensus report by submitting written comments during the review process and oral comments during two forum presentations at the ISPOR 16th and 17th Annual International Meetings held in Baltimore (2011) and Washington, DC (2012). Copyright © 2013 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
How to Flip the Classroom--"Productive Failure or Traditional Flipped Classroom" Pedagogical Design?
ERIC Educational Resources Information Center
Song, Yanjie; Kapur, Manu
2017-01-01
The paper reports a quasi-experimental study comparing the "traditional flipped classroom" pedagogical design with the "productive failure" (Kapur, 2016) pedagogical design in the flipped classroom for a 2-week curricular unit on polynomials in a Hong Kong Secondary school. Different from the flipped classroom where students…
The Design of Time-Series Comparisons under Resource Constraints.
ERIC Educational Resources Information Center
Willemain, Thomas R.; Hartunian, Nelson S.
1982-01-01
Two methods for dividing an interrupted time-series study between baseline and experimental phases when study resources are limited are compared. In fixed designs, the baseline duration is predetermined. In flexible designs the baseline duration is contingent on remaining resources and the match of results to prior expectations of the evaluator.…
ERIC Educational Resources Information Center
Yuruk, Nejla; Beeth, Michael E.; Andersen, Christopher
2009-01-01
This study investigated the effect of metaconceptual teaching interventions on students' understanding of force and motion concepts. A multimethod research design including quasi-experimental design and case study designs was employed to compare the effect of the metaconceptual activities and traditional instruction and investigate students'…
Using R to Simulate Permutation Distributions for Some Elementary Experimental Designs
ERIC Educational Resources Information Center
Eudey, T. Lynn; Kerr, Joshua D.; Trumbo, Bruce E.
2010-01-01
Null distributions of permutation tests for two-sample, paired, and block designs are simulated using the R statistical programming language. For each design and type of data, permutation tests are compared with standard normal-theory and nonparametric tests. These examples (often using real data) provide for classroom discussion use of metrics…
Experimental study of burnout in channels with twisted fuel rods
NASA Astrophysics Data System (ADS)
Bol'Shakov, V. V.; Bashkirtsev, S. M.; Kobzar', L. L.; Morozov, A. G.
2007-05-01
The results of experimental studies of pressure drop and critical heat flux in the models of fuel assemblies (FAs) with fuel rod simulators twisted relative to the longitudinal axis and a three-ray cross section are considered. The experimental data are compared to the results obtained with the use of techniques adopted for design calculations with fuel rod bundles of type-VVER reactors.
ERIC Educational Resources Information Center
Scharfenberg, Franz-Josef; Bogner, Franz X.
2011-01-01
Emphasis on improving higher level biology education continues. A new two-step approach to the experimental phases within an outreach gene technology lab, derived from cognitive load theory, is presented. We compared our approach using a quasi-experimental design with the conventional one-step mode. The difference consisted of additional focused…
ERIC Educational Resources Information Center
Kautz, Tim; Schochet, Peter Z.; Tilley, Charles
2017-01-01
A new design-based theory has recently been developed to estimate impacts for randomized controlled trials (RCTs) and basic quasi-experimental designs (QEDs) for a wide range of designs used in social policy research (Imbens & Rubin, 2015; Schochet, 2016). These methods use the potential outcomes framework and known features of study designs…
Extracting Valuable Data from Classroom Trading Pits
ERIC Educational Resources Information Center
Bergstrom, Theodore C.; Kwok, Eugene
2005-01-01
How well does competitive theory explain the outcome in experimental markets? The authors examined the results of a large number of classroom trading experiments that used a pit-trading design found in Experiments with Economic Principles, an introductory economics textbook by Bergstrom and Miller. They compared experimental outcomes with…
Module-Based Professional Development for Teachers: A Cost-Effective Philippine Experiment
ERIC Educational Resources Information Center
San Antonio, Diosdado M.; Morales, Nelson S.; Moral, Leo S.
2011-01-01
This article examines the impact of implementing module-based professional development for teachers (MBPDT) in the Philippines. A mixed-method study, experimental design with empirical surveys and an open-ended questionnaire revealed that the experimental group of teachers had greater professional content knowledge compared with the control group…
Wear-screening and joint simulation studies vs. materials selection and prosthesis design.
Clarke, I C
1982-01-01
Satisfactory friction and wear performance of orthomedic biomaterials is an essential criterion for both hemiarthroplasty and total joint replacements. This report will chart the clinical historical experience of candidate biomaterials with their wear resistance and compare/contrast these data to experimental test predictions. The latter review will encompass publications dealing with both joint simulators and the more basic friction and wear screening devices. Special consideration will be given to the adequacy of the test protocol, the design of the experimental machines, and the accuracy of the measurement techniques. The discussion will then center on clinical reality vs. experimental adequacy and summarize current developments.
NASA Technical Reports Server (NTRS)
Miller, Rolf W.; Argrow, Brian M.; Center, Kenneth B.; Brauckmann, Gregory J.; Rhode, Matthew N.
1998-01-01
The NASA Langley Research Center Unitary Plan Wind Tunnel and the 20-Inch Mach 6 Tunnel were used to test two osculating cones waverider models. The Mach-4 and Mach-6 shapes were generated using the interactive design tool WIPAR. WIPAR performance predictions are compared to the experimental results. Vapor screen results for the Mach-4 model at the on- design Mach number provide visual verification that the shock is attached along the entire leading edge, within the limits of observation. WIPAR predictions of pressure distributions and aerodynamic coefficients show general agreement with the corresponding experimental values.
Reliability approach to rotating-component design. [fatigue life and stress concentration
NASA Technical Reports Server (NTRS)
Kececioglu, D. B.; Lalli, V. R.
1975-01-01
A probabilistic methodology for designing rotating mechanical components using reliability to relate stress to strength is explained. The experimental test machines and data obtained for steel to verify this methodology are described. A sample mechanical rotating component design problem is solved by comparing a deterministic design method with the new design-by reliability approach. The new method shows that a smaller size and weight can be obtained for specified rotating shaft life and reliability, and uses the statistical distortion-energy theory with statistical fatigue diagrams for optimum shaft design. Statistical methods are presented for (1) determining strength distributions for steel experimentally, (2) determining a failure theory for stress variations in a rotating shaft subjected to reversed bending and steady torque, and (3) relating strength to stress by reliability.
NASA Technical Reports Server (NTRS)
Davis, Don D , Jr; Stokes, George M; Moore, Dewey; Stevens, George L , Jr
1954-01-01
Equations are presented for the attenuation characteristics of single-chamber and multiple-chamber mufflers of both the expansion-chamber and resonator types, for tuned side-branch tubes, and for the combination of an expansion chamber with a resonator. Experimental curves of attenuation plotted against frequency are presented for 77 different mufflers with a reflection-free tailpipe termination. The experiments were made at room temperature without flow; the sound source was a loud-speaker. A method is given for including the tailpipe reflections in the calculations. Experimental attenuation curves are presented for four different muffler-tailpipe combinations, and the results are compared with the theory. The application of the theory to the design of engine-exhaust mufflers is discussed, and charts are included for the assistance of the designer.
An, Ming-Wen; Mandrekar, Sumithra J; Edelman, Martin J; Sargent, Daniel J
2014-07-01
The primary goal of Phase II clinical trials is to understand better a treatment's safety and efficacy to inform a Phase III go/no-go decision. Many Phase II designs have been proposed, incorporating randomization, interim analyses, adaptation, and patient selection. The Phase II design with an option for direct assignment (i.e. stop randomization and assign all patients to the experimental arm based on a single interim analysis (IA) at 50% accrual) was recently proposed [An et al., 2012]. We discuss this design in the context of existing designs, and extend it from a single-IA to a two-IA design. We compared the statistical properties and clinical relevance of the direct assignment design with two IA (DAD-2) versus a balanced randomized design with two IA (BRD-2) and a direct assignment design with one IA (DAD-1), over a range of response rate ratios (2.0-3.0). The DAD-2 has minimal loss in power (<2.2%) and minimal increase in T1ER (<1.6%) compared to a BRD-2. As many as 80% more patients were treated with experimental vs. control in the DAD-2 than with the BRD-2 (experimental vs. control ratio: 1.8 vs. 1.0), and as many as 64% more in the DAD-2 than with the DAD-1 (1.8 vs. 1.1). We illustrate the DAD-2 using a case study in lung cancer. In the spectrum of Phase II designs, the direct assignment design, especially with two IA, provides a middle ground with desirable statistical properties and likely appeal to both clinicians and patients. Copyright © 2014 Elsevier Inc. All rights reserved.
Medarević, Djordje P; Kleinebudde, Peter; Djuriš, Jelena; Djurić, Zorica; Ibrić, Svetlana
2016-01-01
This study for the first time demonstrates combined application of mixture experimental design and artificial neural networks (ANNs) in the solid dispersions (SDs) development. Ternary carbamazepine-Soluplus®-poloxamer 188 SDs were prepared by solvent casting method to improve carbamazepine dissolution rate. The influence of the composition of prepared SDs on carbamazepine dissolution rate was evaluated using d-optimal mixture experimental design and multilayer perceptron ANNs. Physicochemical characterization proved the presence of the most stable carbamazepine polymorph III within the SD matrix. Ternary carbamazepine-Soluplus®-poloxamer 188 SDs significantly improved carbamazepine dissolution rate compared to pure drug. Models developed by ANNs and mixture experimental design well described the relationship between proportions of SD components and percentage of carbamazepine released after 10 (Q10) and 20 (Q20) min, wherein ANN model exhibit better predictability on test data set. Proportions of carbamazepine and poloxamer 188 exhibited the highest influence on carbamazepine release rate. The highest carbamazepine release rate was observed for SDs with the lowest proportions of carbamazepine and the highest proportions of poloxamer 188. ANNs and mixture experimental design can be used as powerful data modeling tools in the systematic development of SDs. Taking into account advantages and disadvantages of both techniques, their combined application should be encouraged.
Xie, Yi; Mun, Sungyong; Kim, Jinhyun; Wang, Nien-Hwa Linda
2002-01-01
A tandem simulated moving bed (SMB) process for insulin purification has been proposed and validated experimentally. The mixture to be separated consists of insulin, high molecular weight proteins, and zinc chloride. A systematic approach based on the standing wave design, rate model simulations, and experiments was used to develop this multicomponent separation process. The standing wave design was applied to specify the SMB operating conditions of a lab-scale unit with 10 columns. The design was validated with rate model simulations prior to experiments. The experimental results show 99.9% purity and 99% yield, which closely agree with the model predictions and the standing wave design targets. The agreement proves that the standing wave design can ensure high purity and high yield for the tandem SMB process. Compared to a conventional batch SEC process, the tandem SMB has 10% higher yield, 400% higher throughput, and 72% lower eluant consumption. In contrast, a design that ignores the effects of mass transfer and nonideal flow cannot meet the purity requirement and gives less than 96% yield.
Skin Microbiome Surveys Are Strongly Influenced by Experimental Design.
Meisel, Jacquelyn S; Hannigan, Geoffrey D; Tyldsley, Amanda S; SanMiguel, Adam J; Hodkinson, Brendan P; Zheng, Qi; Grice, Elizabeth A
2016-05-01
Culture-independent studies to characterize skin microbiota are increasingly common, due in part to affordable and accessible sequencing and analysis platforms. Compared to culture-based techniques, DNA sequencing of the bacterial 16S ribosomal RNA (rRNA) gene or whole metagenome shotgun (WMS) sequencing provides more precise microbial community characterizations. Most widely used protocols were developed to characterize microbiota of other habitats (i.e., gastrointestinal) and have not been systematically compared for their utility in skin microbiome surveys. Here we establish a resource for the cutaneous research community to guide experimental design in characterizing skin microbiota. We compare two widely sequenced regions of the 16S rRNA gene to WMS sequencing for recapitulating skin microbiome community composition, diversity, and genetic functional enrichment. We show that WMS sequencing most accurately recapitulates microbial communities, but sequencing of hypervariable regions 1-3 of the 16S rRNA gene provides highly similar results. Sequencing of hypervariable region 4 poorly captures skin commensal microbiota, especially Propionibacterium. WMS sequencing, which is resource and cost intensive, provides evidence of a community's functional potential; however, metagenome predictions based on 16S rRNA sequence tags closely approximate WMS genetic functional profiles. This study highlights the importance of experimental design for downstream results in skin microbiome surveys. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Skin microbiome surveys are strongly influenced by experimental design
Meisel, Jacquelyn S.; Hannigan, Geoffrey D.; Tyldsley, Amanda S.; SanMiguel, Adam J.; Hodkinson, Brendan P.; Zheng, Qi; Grice, Elizabeth A.
2016-01-01
Culture-independent studies to characterize skin microbiota are increasingly common, due in part to affordable and accessible sequencing and analysis platforms. Compared to culture-based techniques, DNA sequencing of the bacterial 16S ribosomal RNA (rRNA) gene or whole metagenome shotgun (WMS) sequencing provide more precise microbial community characterizations. Most widely used protocols were developed to characterize microbiota of other habitats (i.e. gastrointestinal), and have not been systematically compared for their utility in skin microbiome surveys. Here we establish a resource for the cutaneous research community to guide experimental design in characterizing skin microbiota. We compare two widely sequenced regions of the 16S rRNA gene to WMS sequencing for recapitulating skin microbiome community composition, diversity, and genetic functional enrichment. We show that WMS sequencing most accurately recapitulates microbial communities, but sequencing of hypervariable regions 1-3 of the 16S rRNA gene provides highly similar results. Sequencing of hypervariable region 4 poorly captures skin commensal microbiota, especially Propionibacterium. WMS sequencing, which is resource- and cost-intensive, provides evidence of a community’s functional potential; however, metagenome predictions based on 16S rRNA sequence tags closely approximate WMS genetic functional profiles. This work highlights the importance of experimental design for downstream results in skin microbiome surveys. PMID:26829039
Chang, Soon Bok; Kim, Young Ran; Yoon, Mi Hee; Shim, Joung Un; Ko, Eun Hui; Kim, Min Ok
2004-12-01
The purpose of this study was to compare differences in the time when bowel sounds were heard and gas was passed in women who had an abdominal hysterectomy and were treated for 5 minutes (experimental group A) or 10 minutes (experimental group B) with San-Yin-Jiao (SP-6) acupressure. The design of this study was a nonequivalent control group non-synchronized post test only design. The participants included 142 women, 39 in experimental group A, 30 in experimental group B, and 73 in the control group. Data was collected using a structured questionnaire which included items on general characteristics and a self report of time when gas was passed. Differences for the three groups as to time when bowel sounds were heard and gas was passed were analyzed using ANOVA. The time when bowel sounds were heard was statistically significantly shorter in both experimental groups compared to the control group(F=10.29, p=.000). The time when gas was passed was statistically significantly shorter in experimental group B(10 min) compared to the control group(F=4.68, p=.011). It could be concluded that SP-6 acupressure of 10 minutes was effective in shortening the time until bowel sounds were heard and gas was passed for women who had had an abdominal hysterectomy. Replication of the study with a larger number of participants is necessary in order to be able to generalize the results.
Spanwise morphing trailing edge on a finite wing
NASA Astrophysics Data System (ADS)
Pankonien, Alexander M.; Inman, Daniel J.
2015-04-01
Unmanned Aerial Vehicles are prime targets for morphing implementation as they must adapt to large changes in flight conditions associated with locally varying wind or large changes in mass associated with payload delivery. The Spanwise Morphing Trailing Edge concept locally varies the trailing edge camber of a wing or control surface, functioning as a modular replacement for conventional ailerons without altering the spar box. Utilizing alternating active sections of Macro Fiber Composites (MFCs) driving internal compliant mechanisms and inactive sections of elastomeric honeycombs, the SMTE concept eliminates geometric discontinuities associated with shape change, increasing aerodynamic performance. Previous work investigated a representative section of the SMTE concept and investigated the effect of various skin designs on actuation authority. The current work experimentally evaluates the aerodynamic gains for the SMTE concept for a representative finite wing as compared with a conventional, articulated wing. The comparative performance for both wings is evaluated by measuring the drag penalty associated with achieving a design lift coefficient from an off-design angle of attack. To reduce experimental complexity, optimal control configurations are predicted with lifting line theory and experimentally measured control derivatives. Evaluated over a range of off-design flight conditions, this metric captures the comparative capability of both concepts to adapt or "morph" to changes in flight conditions. Even with this simplistic model, the SMTE concept is shown to reduce the drag penalty due to adaptation up to 20% at off-design conditions, justifying the increase in mass and complexity and motivating concepts capable of larger displacement ranges, higher fidelity modelling, and condition-sensing control.
NASA Technical Reports Server (NTRS)
Smiley, Robert F.; Haines, Gilbert A.
1949-01-01
Bureau of Aeronautics Design Specifications SS-IC-2 for water loads in sheltered water are compared with experimental water loads obtained during a full--scale landing investigation. This investigation was conducted with a JRS-1 flying boat which has a 20 degrees dead-rise V-bottom with a partial chine flare. The range of landing conditions included airspeeds between 88 and 126 feet per second, sinking speeds between 1.6 and 9.1 feet per second, flight angles less than 6 degrees, and trims between 2 degrees and 12 degrees. Landings were moderate and were made in calm water. Measurements were obtained of maximum over-all loads, maximum pitching moments, and pressure distributions. Maximum experimental loads include over-all load factors of 2g, moments of 128,000 pound-feet, and maximum local pressures greater than 40 pounds per square inch. Experimental over-all loads are approximately one-half the design values, while local pressures are of the same order as or larger than pressures calculated from specifications for plating, stringer, floor, and frame design. The value of this comparison is limited, to some extent, by the moderate conditions of the test and by the necessary simplifying assumptions used in comparing the specifications with the experimental loads.
ERIC Educational Resources Information Center
Vincent, Claude; Lachance, Jean-Paul; Deaudelin, Isabelle
2012-01-01
This study sought to compare road safety of new drivers with low vision who have followed a specific pilot bioptic training program with other groups of drivers all matched for age and driving experience. A quasi-experimental design was used two years after drivers obtained their license. Drivers were classified in the experimental group (n = 10,…
NASA Technical Reports Server (NTRS)
Corvelli, N.; Carri, R.
1972-01-01
Results of a study to demonstrate the applicability of boron-epoxy-composite-reinforced titanium tubular members to a space shuttle booster thrust structure are presented and discussed. The experimental results include local buckling of all-composite and composite-reinforced-metal cylinders with low values of diameter-thickness ratio, static tests on composite-to-metal bonded step joints, and a test to failure of a boron-epoxy-reinforced titanium demonstration truss. The demonstration truss failed at 118 percent of design ultimate load. Test results and analysis for all specimens and the truss are compared. Comparing an all-titanium design and a boron-epoxy-reinforced-titanium (75 percent B-E and 25 percent Ti) design for application to the space shuttle booster thrust structure indicates that the latter would weigh approximately 24 percent less. Experimental data on the local buckling strength of cylinders with a diameter-thickness ratio of approximately 50 are needed to insure that undue conservatism is not used in future designs.
Design and performance testing of an ultrasonic linear motor with dual piezoelectric actuators.
Smithmaitrie, Pruittikorn; Suybangdum, Panumas; Laoratanakul, Pitak; Muensit, Nantakan
2012-05-01
In this work, design and performance testing of an ultrasonic linear motor with dual piezoelectric actuator patches are studied. The motor system consists of a linear stator, a pre-load weight, and two piezoelectric actuator patches. The piezoelectric actuators are bonded with the linear elastic stator at specific locations. The stator generates propagating waves when the piezoelectric actuators are subjected to harmonic excitations. Vibration characteristics of the linear stator are analyzed and compared with finite element and experimental results. The analytical, finite element, and experimental results show agreement. In the experiments, performance of the ultrasonic linear motor is tested. Relationships between velocity and pre-load weight, velocity and applied voltage, driving force and applied voltage, and velocity and driving force are reported. The design of the dual piezoelectric actuators yields a simpler structure with a smaller number of actuators and lower stator stiffness compared with a conventional design of an ultrasonic linear motor with fully laminated piezoelectric actuators.
Comparative study on diagonal equivalent methods of masonry infill panel
NASA Astrophysics Data System (ADS)
Amalia, Aniendhita Rizki; Iranata, Data
2017-06-01
Infrastructure construction in earthquake prone area needs good design process, including modeling a structure in a correct way to reduce damages caused by an earthquake. Earthquakes cause many damages e.g. collapsed buildings that are dangerous. An incorrect modeling in design process certainly affects the structure's ability in responding to load, i.e. an earthquake load, and it needs to be paid attention to in order to reduce damages and fatalities. A correct modeling considers every aspect that affects the strength of a building, including stiffness of resisting lateral loads caused by an earthquake. Most of structural analyses still use open frame method that does not consider the effect of stiffness of masonry panel to the stiffness and strength of the whole structure. Effect of masonry panel is usually not included in design process, but the presence of this panel greatly affects behavior of the building in responding to an earthquake. In worst case scenario, it can even cause the building to collapse as what has been reported after great earthquakes worldwide. Modeling a structure with masonry panel as consideration can be performed by designing the panel as compression brace or shell element. In designing masonry panel as a compression brace, there are fourteen methods popular to be used by structure designers formulated by Saneinejad-Hobbs, Holmes, Stafford-Smith, Mainstones, Mainstones-Weeks, Bazan-Meli, Liauw Kwan, Paulay and Priestley, FEMA 356, Durani Luo, Hendry, Al-Chaar, Papia and Chen-Iranata. Every method has its own equation and parameters to use, therefore the model of every method was compared to results of experimental test to see which one gives closer values. Moreover, those methods also need to be compared to the open frame to see if they can result values within limits. Experimental test that was used in comparing all methods was taken from Mehrabi's research (Fig. 1), which was a prototype of a frame in a structure with 0.5 scale and the ratio of height to width of 1 to 1.5. Load used in the experiment was based on Uniform Building Code (UBC) 1991. Every method compared was calculated first to get equivalent diagonal strut width. The second step was modelling method using structure analysis software as a frame with a diagonal in a linear mode. The linear mode was chosen based on structure analysis commonly used by structure designers. The frame was loaded and for every model, its load and deformation values were identified. The values of load - deformation of every method were compared to those of experimental test specimen by Mehrabi and open frame. From comparative study performed, Holmes' and Bazan-Meli's equations gave results the closest to the experimental test specimen by Mehrabi. Other equations that gave close values within the limit (by comparing it to the open frame) are Saneinejad-Hobbs, Stafford-Smith, Bazan-Meli, Liauw Kwan, Paulay and Priestley, FEMA 356, Durani Luo, Hendry, Papia and Chen-Iranata.
NASA Astrophysics Data System (ADS)
Thamvichai, Ratchaneekorn; Huang, Liang-Chih; Ashok, Amit; Gong, Qian; Coccarelli, David; Greenberg, Joel A.; Gehm, Michael E.; Neifeld, Mark A.
2017-05-01
We employ an adaptive measurement system, based on sequential hypotheses testing (SHT) framework, for detecting material-based threats using experimental data acquired on an X-ray experimental testbed system. This testbed employs 45-degree fan-beam geometry and 15 views over a 180-degree span to generate energy sensitive X-ray projection data. Using this testbed system, we acquire multiple view projection data for 200 bags. We consider an adaptive measurement design where the X-ray projection measurements are acquired in a sequential manner and the adaptation occurs through the choice of the optimal "next" source/view system parameter. Our analysis of such an adaptive measurement design using the experimental data demonstrates a 3x-7x reduction in the probability of error relative to a static measurement design. Here the static measurement design refers to the operational system baseline that corresponds to a sequential measurement using all the available sources/views. We also show that by using adaptive measurements it is possible to reduce the number of sources/views by nearly 50% compared a system that relies on static measurements.
NASA Astrophysics Data System (ADS)
Huynh, Trong-Phuoc; Hwang, Chao-Lung; Yang, Shu-Ti
2017-12-01
This experimental study evaluated the performance of normal ordinary Portland cement (OPC) concrete and high-performance concrete (HPC) that were designed by the conventional method (ACI) and densified mixture design algorithm (DMDA) method, respectively. Engineering properties and durability performance of both the OPC and HPC samples were studied using the tests of workability, compressive strength, water absorption, ultrasonic pulse velocity, and electrical surface resistivity. Test results show that the HPC performed good fresh property and further showed better performance in terms of strength and durability as compared to the OPC.
A Model for Evaluating Programs for the Gifted under Non-Experimental Conditions.
ERIC Educational Resources Information Center
Carter, Kyle R.
1992-01-01
The article presents and illustrates use of an evaluation model for assessing programs for the gifted where tight experimental control is not possible. The model consists of four components: ex post factor designs including intact groups; comparative evaluation; strength of treatment; and multiple outcome assessment from flexible data sources. (DB)
Experimental Evaluation of the Tools of the Mind Pre-K Curriculum. Technical Report. Working Paper
ERIC Educational Resources Information Center
Farran, Dale C.; Wilson, Sandra J.; Meador, Deanna; Norvell, Jennifer; Nesbitt, Kimberly
2015-01-01
The experimental evaluation of the "Tools of the Mind Pre-K Curriculum" described in this report was designed to examine the effectiveness of the "Tools of the Mind" ("Tools") curriculum for enhancing children's self-regulation skills and their academic preparation for kindergarten when compared to the usual…
Real Reality Revisited: An Experimental Communicative Course in ESL.
ERIC Educational Resources Information Center
Montgomery, Carol; Eisenstein, Miriam
1985-01-01
Describes an experimental oral communication course designed around weekly, structured field trips to sites where students typically need to communicate in English. Students taking this course were also enrolled in a grammar-based English as a second-language course and were compared with a control group taking only the grammar-based course. (SED)
Replicating Experimental Impact Estimates Using a Regression Discontinuity Approach. NCEE 2012-4025
ERIC Educational Resources Information Center
Gleason, Philip M.; Resch, Alexandra M.; Berk, Jillian A.
2012-01-01
This NCEE Technical Methods Paper compares the estimated impacts of an educational intervention using experimental and regression discontinuity (RD) study designs. The analysis used data from two large-scale randomized controlled trials--the Education Technology Evaluation and the Teach for America Study--to provide evidence on the performance of…
Essays on Experimental Economics and Education
ERIC Educational Resources Information Center
Ogawa, Scott Richard
2013-01-01
In Chapter 1 I consider three separate explanations for how price affects the usage rate of a purchased product: Screening, signaling, and sunk-cost bias. I propose an experimental design that disentangles the three effects. Furthermore, in order to quantify and compare these effects I introduce a simple structural model and show that the…
ERIC Educational Resources Information Center
Chang, Hsin-Yi
2017-01-01
Two investigations were conducted in this study. In the first experiment, the effects of two types of interactivity with a computer simulation were compared: experimentation versus observation interactivity. Experimentation interactivity allows students to use simulations to conduct virtual experiments, whereas observation interactivity allows…
Promoting Healthy Eating in Nursery Schoolchildren: A Quasi-Experimental Intervention Study
ERIC Educational Resources Information Center
Korwanich, Kanyarat; Sheiham, Aubrey; Srisuphan, Wichit; Srisilapanan, Patcharawan
2008-01-01
Objective: To evaluate the effects of implementing a healthy eating policy on nursery schoolchildren's dietary practices in nurseries in Phrae Province, Thailand. Design: Quasi-experimental action research was used to compare the effects of school healthy eating policy on the diets of nursery schoolchildren in eight intervention and eight matched…
Optimal active vibration absorber: Design and experimental results
NASA Technical Reports Server (NTRS)
Lee-Glauser, Gina; Juang, Jer-Nan; Sulla, Jeffrey L.
1992-01-01
An optimal active vibration absorber can provide guaranteed closed-loop stability and control for large flexible space structures with collocated sensors/actuators. The active vibration absorber is a second-order dynamic system which is designed to suppress any unwanted structural vibration. This can be designed with minimum knowledge of the controlled system. Two methods for optimizing the active vibration absorber parameters are illustrated: minimum resonant amplitude and frequency matched active controllers. The Controls-Structures Interaction Phase-1 Evolutionary Model at NASA LaRC is used to demonstrate the effectiveness of the active vibration absorber for vibration suppression. Performance is compared numerically and experimentally using acceleration feedback.
NASA Technical Reports Server (NTRS)
Steinke, R. J.
1982-01-01
A FORTRAN computer code is presented for off-design performance prediction of axial-flow compressors. Stage and compressor performance is obtained by a stage-stacking method that uses representative velocity diagrams at rotor inlet and outlet meanline radii. The code has options for: (1) direct user input or calculation of nondimensional stage characteristics; (2) adjustment of stage characteristics for off-design speed and blade setting angle; (3) adjustment of rotor deviation angle for off-design conditions; and (4) SI or U.S. customary units. Correlations from experimental data are used to model real flow conditions. Calculations are compared with experimental data.
Lee, Jung Bok; Choi, So Young
2015-10-01
The purpose of this study was to investigate the effects of pelvic floor muscle exercise using electric stimulation and biofeedback on maximum pressure of vaginal contraction, vaginal contraction duration and sexual function in women who have had vaginal rejuvenation. The research design was a non-equivalent control group non-synchronized design study. Participants in this study were women who had vaginal rejuvenation at C obstetrics and gynecology hospital. The 15 participants in the experimental group were given pelvic floor muscle exercise using electric stimulation and biofeedback and the 15 participants in the control group received self pelvic floor muscle exercise. For maximum pressure of vaginal contraction, the experimental group showed a statistically significant increase compared to than the control group (t=5.96, p<.001). For vaginal contraction duration, the experimental group also showed a statistically significant increase compared to the control group (t=3.23, p=.003). For women's sexual function, the experimental group showed a significant increase when compared to the control group in total sexual function scores (t=3.41, p=.002). The results indicate that pelvic floor muscle exercise with electric stimulation and biofeedback after vaginal rejuvenation is effective in strengthening vaginal contraction pressure, vaginal contraction and that it also positively functions to increase women's sexual function.
76 FR 10573 - Notice of Proposed Information Collection Requests
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-25
... study will use quasi- experimental designs to explore the relationship between magnet programs and... that (1) described the study design and full data collection activities and (2) requested approval for... associated with the fourth and fifth year of data collection necessary for the rigorous comparative...
2017-04-01
commercial designs . The Navy planned to experiment with these ships to determine its preferred design variant. This experimentation strategy was...utilizing other non -LCS designs .6 When presented with this conclusion, senior Navy leadership directed the task force to explore what capabilities... compared to the LCS. Since the frigate will be based on an LCS design , it will likely carry forward some LCS design limitations. For example, LCS is
Dijkstra, Arie; Zuidema, Rixt; Vos, Diederick; van Kalken, Marike
2014-09-13
The Allen Carr training (ACt) is a popular one-session smoking cessation group training that is provided by licensed organizations that have the permission to use the Allen Carr method. However, few data are available on the effectiveness of the training. In a quasi-experimental design the effects of the existing practice of providing the ACt to smokers (n = 124) in companies on abstinence, were compared to changes in abstinence in a cohort of similar smokers in the general population (n = 161). To increase comparability of the smokers in both conditions, smokers in the control condition were matched on the group level on baseline characteristics (fourteen variables) to the smokers in the ACt. The main outcome measure was self-reported continuous abstinence after 13 months, which was validated using a CO measurement in the Act condition. Logistic regression analyses showed that when baseline characteristics were comparable, significantly more responding smokers were continuously abstinent in the ACt condition compared to the control condition, Exp(B) = 6.52 (41.1% and 9.6%, respectively). The all-cases analysis was also significant, Exp(B) = 5.09 (31.5% and 8.3%, respectively). Smokers following the ACt in their company were about 6 times more likely to be abstinent, assessed after 13 months, compared to similar smokers in the general population. Although smokers in both conditions did not differ significantly on 14 variables that might be related to cessation success, the quasi-experimental design allows no definite conclusion about the effectiveness of the ACt. Still, these data support the provision of the ACt in companies.
Integrated CFD modeling of gas turbine combustors
NASA Technical Reports Server (NTRS)
Fuller, E. J.; Smith, C. E.
1993-01-01
3D, curvilinear, multi-domain CFD analysis is becoming a valuable tool in gas turbine combustor design. Used as a supplement to experimental testing. CFD analysis can provide improved understanding of combustor aerodynamics and used to qualitatively assess new combustor designs. This paper discusses recent advancements in CFD combustor methodology, including the timely integration of the design (i.e. CAD) and analysis (i.e. CFD) processes. Allied Signal's F124 combustor was analyzed at maximum power conditions. The assumption of turbulence levels at the nozzle/swirler inlet was shown to be very important in the prediction of combustor exit temperatures. Predicted exit temperatures were compared to experimental rake data, and good overall agreement was seen. Exit radial temperature profiles were well predicted, while the predicted pattern factor was 25 percent higher than the harmonic-averaged experimental pattern factor.
Shin, Sangmun; Choi, Du Hyung; Truong, Nguyen Khoa Viet; Kim, Nam Ah; Chu, Kyung Rok; Jeong, Seong Hoon
2011-04-04
A new experimental design methodology was developed by integrating the response surface methodology and the time series modeling. The major purposes were to identify significant factors in determining swelling and release rate from matrix tablets and their relative factor levels for optimizing the experimental responses. Properties of tablet swelling and drug release were assessed with ten factors and two default factors, a hydrophilic model drug (terazosin) and magnesium stearate, and compared with target values. The selected input control factors were arranged in a mixture simplex lattice design with 21 experimental runs. The obtained optimal settings for gelation were PEO, LH-11, Syloid, and Pharmacoat with weight ratios of 215.33 (88.50%), 5.68 (2.33%), 19.27 (7.92%), and 3.04 (1.25%), respectively. The optimal settings for drug release were PEO and citric acid with weight ratios of 191.99 (78.91%) and 51.32 (21.09%), respectively. Based on the results of matrix swelling and drug release, the optimal solutions, target values, and validation experiment results over time were similar and showed consistent patterns with very small biases. The experimental design methodology could be a very promising experimental design method to obtain maximum information with limited time and resources. It could also be very useful in formulation studies by providing a systematic and reliable screening method to characterize significant factors in the sustained release matrix tablet. Copyright © 2011 Elsevier B.V. All rights reserved.
Optimizing methods and dodging pitfalls in microbiome research.
Kim, Dorothy; Hofstaedter, Casey E; Zhao, Chunyu; Mattei, Lisa; Tanes, Ceylan; Clarke, Erik; Lauder, Abigail; Sherrill-Mix, Scott; Chehoud, Christel; Kelsen, Judith; Conrad, Máire; Collman, Ronald G; Baldassano, Robert; Bushman, Frederic D; Bittinger, Kyle
2017-05-05
Research on the human microbiome has yielded numerous insights into health and disease, but also has resulted in a wealth of experimental artifacts. Here, we present suggestions for optimizing experimental design and avoiding known pitfalls, organized in the typical order in which studies are carried out. We first review best practices in experimental design and introduce common confounders such as age, diet, antibiotic use, pet ownership, longitudinal instability, and microbial sharing during cohousing in animal studies. Typically, samples will need to be stored, so we provide data on best practices for several sample types. We then discuss design and analysis of positive and negative controls, which should always be run with experimental samples. We introduce a convenient set of non-biological DNA sequences that can be useful as positive controls for high-volume analysis. Careful analysis of negative and positive controls is particularly important in studies of samples with low microbial biomass, where contamination can comprise most or all of a sample. Lastly, we summarize approaches to enhancing experimental robustness by careful control of multiple comparisons and to comparing discovery and validation cohorts. We hope the experimental tactics summarized here will help researchers in this exciting field advance their studies efficiently while avoiding errors.
Comparative Cognitive Task Analyses of Experimental Science and Instructional Laboratory Courses
NASA Astrophysics Data System (ADS)
Wieman, Carl
2015-09-01
Undergraduate instructional labs in physics generate intense opinions. Their advocates are passionate as to their importance for teaching physics as an experimental activity and providing "hands-on" learning experiences, while their detractors (often but not entirely students) offer harsh criticisms that they are pointless, confusing and unsatisfying, and "cookbook." Here, both to help understand the reason for such discrepant views and to aid in the design of instructional lab courses, I compare the mental tasks or types of thinking ("cognitive task analysis") associated with a physicist doing tabletop experimental research with the cognitive tasks of students in an introductory physics instructional lab involving traditional verification/confirmation exercises.
Investigations into Novel Multi-Band Antenna Designs
2006-08-01
endeavouring to modify the designs to incorporate dual polarisation , building the antennas, as well as experimental work that will use the manufactured...based on the Koch, Minkowski and Hilbert curves. The merit in this approach is that non -Euclidean designs (i.e. fractals) are compared with Euclidean... polarisation . A number of possible changes to the current design need to be explored towards achieving the above objectives. Some of the suggested
Design and development aspects of flexure mechanism for high precision application
NASA Astrophysics Data System (ADS)
Sollapur, Shrishail B.; Patil, M. S.; Deshmukh, S. P.
2018-04-01
Planer XY Flexurel Mechanisms has various applications in precision motion mechanisms. A flexural mechanism generates relative motion between fixed support and motion stage using flexibility of material. This mechanism offers zero backlash, frictionless motion and high order repeatability. It is relatively compact in design as compared to rigid link mechanism. The merits of using flexure is complete mechanism can be from single monolith. Modelling of flexural mechanism to provide accurate scanning of comparatively larger range at a higher speed. Static Analysis of mechanism is carried out on FEA tool to determine static deflection of motion stage. Further Mechanism is actuated with the help of weight pan and weights. The resultant displacement is measured on Dial Gauge Indicator. Experimental set-up consists of Flexural mechanism, Dial Gauge, Weight Pan and Weights, Pulley, String, Small metal strip, Optical Bread Board etc. Further experimental Results and Analytical Results are compared and minimum deviation is found.
Elementary Students' Laboratory Record Keeping during Scientific Inquiry
ERIC Educational Resources Information Center
Garcia-Mila, Merce; Andersen, Christopher; Rojo, Nubia E.
2011-01-01
The present study examines the mutual interaction between students' writing and scientific reasoning among sixth-grade students (age 11-12 years) engaged in scientific inquiry. The experimental task was designed to promote spontaneous record keeping compared to previous task designs by increasing the saliency of task requirements, with the design…
Plaque removal efficacy of a battery-operated toothbrush compared to a manual toothbrush.
Ruhlman, C D; Bartizek, R D; Biesbrock, A R
2001-08-01
Recently, a new power toothbrush has been marketed with a design that fundamentally differs from other marketed power toothbrushes, in that it incorporates a round oscillating head, in conjunction with fixed bristles. The objective of this study was to compare the plaque removal efficacy of a control manual toothbrush (Colgate Navigator) to this experimental power toothbrush (Crest SpinBrush) following a single use. This study was a randomized, controlled, examiner-blind, 4-period crossover design which examined plaque removal with the two toothbrushes following a single use in 40 completed subjects. Plaque was scored before and after brushing using the Turesky Modification of the Quigley-Hein Index. Baseline plaque scores were 1.77 for both the experimental toothbrush and control toothbrush treatment groups. With respect to all surfaces examined, the experimental toothbrush delivered an adjusted (via analysis of covariance) mean difference between baseline and post-brushing plaque scores of 0.48 while the control toothbrush delivered an adjusted mean difference of 0.35. The experimental toothbrush removed, on average, 37.6% more plaque than the control toothbrush. These results were statistically significant (P< 0.001). With respect to buccal surfaces, the experimental toothbrush delivered an adjusted mean difference between baseline and post-brushing plaque scores of 0.54 while the control toothbrush delivered an adjusted mean difference of 0.42. This represents 27.8% more plaque removal with the experimental toothbrush compared to the control toothbrush. These results were also statistically significant (P= 0.001). Results on lingual surfaces also demonstrated statistically significantly (P< 0.001) greater plaque removal for the experimental toothbrush with an average of 53.4% more plaque removal.
Roles of Naturalistic Observation in Comparative Psychology
ERIC Educational Resources Information Center
Miller, David B.
1977-01-01
"Five roles are considered by which systematic, quantified field research can augment controlled laboratory experimentation in terms of increasing the validity of laboratory studies." Advocates that comparative psychologists should "take more initiative in designing, executing, and interpreting our experiments with regard to the natural history of…
Experimental Investigation of Flame Stability in Porous Media Burners
NASA Astrophysics Data System (ADS)
Mohaddes, Danyal; Sobhani, Sadaf; Boigne, Emeric; Muhunthan, Priyanka; Ihme, Matthias
2017-11-01
Porous media burners (PMBs) facilitate the stabilization of a flame inside the pores of a solid porous material, and have benefits when compared to traditional burners in terms of emissions reduction and operating envelope extension. PMBs can potentially find application in a wide variety of domains, including household and industrial heating, internal combustion engines, and gas turbine engine combustors. The current study aims to motivate the use of PMBs in such applications on a thermodynamic basis, and subsequently compares the performance of two PMB designs. To this end, an experiment was devised and conducted to determine the stable operating conditions of a continuously varying and a discontinuously varying pore diameter profile PMB. In addition to investigating the stability regime of each design, pressure drop and axial temperatures were measured and compared at different operating conditions. The collected experimental data will be used both to inform computational studies of combustion within porous media and to aid in future optimizations of the design of PMBs. This work is supported by a Leading Edge Aeronautics Research for NASA (LEARN) Grant (Award No. NNX15AE42A).
Tsipa, Argyro; Koutinas, Michalis; Usaku, Chonlatep; Mantalaris, Athanasios
2018-05-02
Currently, design and optimisation of biotechnological bioprocesses is performed either through exhaustive experimentation and/or with the use of empirical, unstructured growth kinetics models. Whereas, elaborate systems biology approaches have been recently explored, mixed-substrate utilisation is predominantly ignored despite its significance in enhancing bioprocess performance. Herein, bioprocess optimisation for an industrially-relevant bioremediation process involving a mixture of highly toxic substrates, m-xylene and toluene, was achieved through application of a novel experimental-modelling gene regulatory network - growth kinetic (GRN-GK) hybrid framework. The GRN model described the TOL and ortho-cleavage pathways in Pseudomonas putida mt-2 and captured the transcriptional kinetics expression patterns of the promoters. The GRN model informed the formulation of the growth kinetics model replacing the empirical and unstructured Monod kinetics. The GRN-GK framework's predictive capability and potential as a systematic optimal bioprocess design tool, was demonstrated by effectively predicting bioprocess performance, which was in agreement with experimental values, when compared to four commonly used models that deviated significantly from the experimental values. Significantly, a fed-batch biodegradation process was designed and optimised through the model-based control of TOL Pr promoter expression resulting in 61% and 60% enhanced pollutant removal and biomass formation, respectively, compared to the batch process. This provides strong evidence of model-based bioprocess optimisation at the gene level, rendering the GRN-GK framework as a novel and applicable approach to optimal bioprocess design. Finally, model analysis using global sensitivity analysis (GSA) suggests an alternative, systematic approach for model-driven strain modification for synthetic biology and metabolic engineering applications. Copyright © 2018. Published by Elsevier Inc.
ERIC Educational Resources Information Center
Owusu, K. A.; Monney, K. A.; Appiah, J. Y.; Wilmot, E. M.
2010-01-01
This study investigated the comparative efficiency of computer-assisted instruction (CAI) and conventional teaching method in biology on senior high school students. A science class was selected in each of two randomly selected schools. The pretest-posttest non equivalent quasi experimental design was used. The students in the experimental group…
ERIC Educational Resources Information Center
Duran, Lillian K.; Roseth, Cary J.; Hoffman, Patricia
2010-01-01
A longitudinal, experimental-control design was used to test the hypothesis that native language instruction enhances English language learner's (ELL's) native language and literacy development without significant cost to English development. In this study, 31 Spanish-speaking preschoolers (aged 38-48 months) were randomly assigned to two Head…
ERIC Educational Resources Information Center
Meador, Deanna; Nesbitt, Kimberly; Farran, Dale
2015-01-01
The "Experimental Evaluation of the Tools of the Mind Pre-K Curriculum" study was designed to compare the effectiveness of the "Tools of the Mind" ("Tools") curriculum to the curricula the school system is currently using in enhancing children's self-regulation skills and their academic preparation for kindergarten.…
Answer Me These Questions Three: Using Online Training to Improve Students' Oral Source Citations
ERIC Educational Resources Information Center
Buerkle, C. Wesley; Gearhart, Christopher C.
2017-01-01
This experimental study examines an online module designed to increase student competence in oral citation behavior using a mastery training strategy. Students in the experimental condition provided complete citations at a higher rate and provided more citation information for traditional and web-based sources compared with a control group without…
The Effects of Using Selected Metacognitive Strategies on ACT Mathematics Sub-Test Scores
ERIC Educational Resources Information Center
LeMay, Jeffrey W.
2016-01-01
This quasi-experimental post-test only control group designed quantitative study examined whether or not members of an experimental group of participants who utilized two metacognitive strategy training regimens experienced a significant increase in their ACT mathematics sub-test scores compared to a group of students who did not utilize either of…
2017-03-01
experimental effort involving a series of +z-axis impact tests was conducted on the 711th Human Performance Wing’s Vertical Deceleration Tower (VDT...parameters) and a JSF-styled ejection seat configuration (combined non -baseline test parameters) produced similar biodynamic response parameters for the LOIS...Photography .............................................................................. 12 6.0 EXPERIMENTAL DESIGN
ERIC Educational Resources Information Center
Bear, Teresa J.
2013-01-01
This quantitative action science research study utilized a causal-comparative experimental research design in order to determine if the use of student response systems (clickers), as an active learning strategy in a community college course, improved student performance in the course. Students in the experimental group (n = 26) used clickers to…
Systematic review of control groups in nutrition education intervention research.
Byrd-Bredbenner, Carol; Wu, FanFan; Spaccarotella, Kim; Quick, Virginia; Martin-Biggers, Jennifer; Zhang, Yingting
2017-07-11
Well-designed research trials are critical for determining the efficacy and effectiveness of nutrition education interventions. To determine whether behavioral and/or cognition changes can be attributed to an intervention, the experimental design must include a control or comparison condition against which outcomes from the experimental group can be compared. Despite the impact different types of control groups can have on study outcomes, the treatment provided to participants in the control condition has received limited attention in the literature. A systematic review of control groups in nutrition education interventions was conducted to better understand how control conditions are described in peer-reviewed journal articles compared with experimental conditions. To be included in the systematic review, articles had to be indexed in CINAHL, PubMed, PsycINFO, WoS, and/or ERIC and report primary research findings of controlled nutrition education intervention trials conducted in the United States with free-living consumer populations and published in English between January 2005 and December 2015. Key elements extracted during data collection included treatment provided to the experimental and control groups (e.g., overall intervention content, tailoring methods, delivery mode, format, duration, setting, and session descriptions, and procedures for standardizing, fidelity of implementation, and blinding); rationale for control group type selected; sample size and attrition; and theoretical foundation. The search yielded 43 publications; about one-third of these had an inactive control condition, which is considered a weak study design. Nearly two-thirds of reviewed studies had an active control condition considered a stronger research design; however, many failed to report one or more key elements of the intervention, especially for the control condition. None of the experimental and control group treatments were sufficiently detailed to permit replication of the nutrition education interventions studied. Findings advocate for improved intervention study design and more complete reporting of nutrition education interventions.
Zoned near-zero refractive index fishnet lens antenna: Steering millimeter waves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pacheco-Peña, V., E-mail: victor.pacheco@unavarra.es; Orazbayev, B., E-mail: b.orazbayev@unavarra.es; Beaskoetxea, U., E-mail: unai.beaskoetxea@unavarra.es
2014-03-28
A zoned fishnet metamaterial lens is designed, fabricated, and experimentally demonstrated at millimeter wavelengths to work as a negative near-zero refractive index lens suitable for compact lens antenna configurations. At the design frequency f = 56.7 GHz (λ{sub 0} = 5.29 mm), the zoned fishnet metamaterial lens, designed to have a focal length FL = 9λ{sub 0}, exhibits a refractive index n = −0.25. The focusing performance of the diffractive optical element is briefly compared with that of a non-zoned fishnet metamaterial lens and an isotropic homogeneous zoned lens made of a material with the same refractive index. Experimental and numerically-computed radiation diagrams of the fabricated zoned lens are presentedmore » and compared in detail with that of a simulated non-zoned lens. Simulation and experimental results are in good agreement, demonstrating an enhancement generated by the zoned lens of 10.7 dB, corresponding to a gain of 12.26 dB. Moreover, beam steering capability of the structure by shifting the feeder on the xz-plane is demonstrated.« less
Factorial Experiments: Efficient Tools for Evaluation of Intervention Components
Collins, Linda M.; Dziak, John J.; Kugler, Kari C.; Trail, Jessica B.
2014-01-01
Background An understanding of the individual and combined effects of a set of intervention components is important for moving the science of preventive medicine interventions forward. This understanding can often be achieved in an efficient and economical way via a factorial experiment, in which two or more independent variables are manipulated. The factorial experiment is a complement to the randomized controlled trial (RCT); the two designs address different research questions. Purpose This article offers an introduction to factorial experiments aimed at investigators trained primarily in the RCT. Method The factorial experiment is compared and contrasted with other experimental designs used commonly in intervention science to highlight where each is most efficient and appropriate. Results Several points are made: factorial experiments make very efficient use of experimental subjects when the data are properly analyzed; a factorial experiment can have excellent statistical power even if it has relatively few subjects per experimental condition; and when conducting research to select components for inclusion in a multicomponent intervention, interactions should be studied rather than avoided. Conclusions Investigators in preventive medicine and related areas should begin considering factorial experiments alongside other approaches. Experimental designs should be chosen from a resource management perspective, which states that the best experimental design is the one that provides the greatest scientific benefit without exceeding available resources. PMID:25092122
Experimental Design and Primary Data Analysis Methods for Comparing Adaptive Interventions
Nahum-Shani, Inbal; Qian, Min; Almirall, Daniel; Pelham, William E.; Gnagy, Beth; Fabiano, Greg; Waxmonsky, Jim; Yu, Jihnhee; Murphy, Susan
2013-01-01
In recent years, research in the area of intervention development is shifting from the traditional fixed-intervention approach to adaptive interventions, which allow greater individualization and adaptation of intervention options (i.e., intervention type and/or dosage) over time. Adaptive interventions are operationalized via a sequence of decision rules that specify how intervention options should be adapted to an individual’s characteristics and changing needs, with the general aim to optimize the long-term effectiveness of the intervention. Here, we review adaptive interventions, discussing the potential contribution of this concept to research in the behavioral and social sciences. We then propose the sequential multiple assignment randomized trial (SMART), an experimental design useful for addressing research questions that inform the construction of high-quality adaptive interventions. To clarify the SMART approach and its advantages, we compare SMART with other experimental approaches. We also provide methods for analyzing data from SMART to address primary research questions that inform the construction of a high-quality adaptive intervention. PMID:23025433
NASA Technical Reports Server (NTRS)
Paillat, O.; Wasserburg, G. J.
1993-01-01
Experimental studies of self-diffusion isotopes in silicate melts often have quite large uncertainties when comparing one study to another. We designed an experiment in order to improve the precision of the results by simultaneously studying several elements (Mg, Ca, Sr, Ba) during the same experiment thereby greatly reducing the relative experimental uncertainties. Results show that the uncertainties on the diffusion coefficients can be reduced to 10 percent, allowing a more reliable comparison of differences of self-diffusion coefficients of the elements. This type of experiment permits us to study precisely and simultaneously several elements with no restriction on any element. We also designed an experiment to investigate the possible effects of multicomponent diffusion during Mg self-diffusion experiments by comparing cases where the concentrations of the elements and the isotopic compositions are different. The results suggest that there are differences between the effective means of transport. This approach should allow us to investigate the importance of multicomponent diffusion in silicate melts.
The Penn State Safety Floor: Part I--Design parameters associated with walking deflections.
Casalena, J A; Ovaert, T C; Cavanagh, P R; Streit, D A
1998-08-01
A new flooring system has been developed to reduce peak impact forces to the hips when humans fall. The new safety floor is designed to remain relatively rigid under normal walking conditions, but to deform elastically when impacted during a fall. Design objectives included minimizing peak force experienced by the femur during a fall-induced impact, while maintaining a maximum of 2 mm of floor deflection during walking. Finite Element Models (FEMs) were developed to capture the complex dynamics of impact response between two deformable bodies. Validation of the finite element models included analytical calculations of theoretical buckling column response, experimental quasi-static loading of full-scale flooring prototypes, and flooring response during walking trials. Finite Element Method results compared well with theoretical and experimental data. Both finite element and experimental data suggest that the proposed safety floor can effectively meet the design goal of 2 mm maximum deflection during walking, while effectively reducing impact forces during a fall.
Development of Switchable Polarity Solvent Draw Solutes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, Aaron D.
Results of a computational fluid dynamic (CFD) study of flow and heat transfer in a printed circuit heat exchanger (PCHE) geometry are presented. CFD results obtained from a two-plate model are compared to corresponding experimental results for the validation. This process provides the basis for further application of the CFD code to PCHE design and performance analysis in a variety of internal flow geometries. As a part of the code verification and validation (V&V) process, CFD simulation of a single semicircular straight channel under laminar isothermal conditions was also performed and compared to theoretical results. This comparison yielded excellent agreementmore » with the theoretical values. The two-plate CFD model based on the experimental PCHE design overestimated the effectiveness and underestimated the pressure drop. However, it is found that the discrepancy between the CFD result and experimental data was mainly caused by the uncertainty in the geometry of heat exchanger during the fabrication. The CFD results obtained using a slightly smaller channel diameter yielded good agreement with the experimental data. A separate investigation revealed that the average channel diameter of the OSU PCHE after the diffusion-bonding was 1.93 mm on the cold fluid side and 1.90 mm on the hot fluid side which are both smaller than the nominal design value. Consequently, the CFD code was shown to have sufficient capability to evaluate the heat exchanger thermal-hydraulic performance.« less
Experimental investigation of terahertz quantum cascade laser with variable barrier heights
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Aiting; Vijayraghavan, Karun; Belkin, Mikhail A., E-mail: mbelkin@ece.utexas.edu
2014-04-28
We report an experimental study of terahertz quantum cascade lasers with variable barrier heights based on the Al{sub x}Ga{sub 1–x}As/GaAs material system. Two new designs are developed based on semiclassical ensemble Monte Carlo simulations using state-of-the-art Al{sub 0.15}Ga{sub 0.85}As/GaAs three-quantum-well resonant phonon depopulation active region design as a reference. The new designs achieved maximum lasing temperatures of 188 K and 172 K, as compared to the maximum lasing temperature of 191 K for the reference structure. These results demonstrate that terahertz quantum cascade laser designs with variable barrier heights provide a viable alternative to the traditional active region designs with fixed barrier composition.more » Additional design space offered by using variable barriers may lead to future improvements in the terahertz quantum cascade laser performance.« less
Heinsch, Stephen C.; Das, Siba R.; Smanski, Michael J.
2018-01-01
Increasing the final titer of a multi-gene metabolic pathway can be viewed as a multivariate optimization problem. While numerous multivariate optimization algorithms exist, few are specifically designed to accommodate the constraints posed by genetic engineering workflows. We present a strategy for optimizing expression levels across an arbitrary number of genes that requires few design-build-test iterations. We compare the performance of several optimization algorithms on a series of simulated expression landscapes. We show that optimal experimental design parameters depend on the degree of landscape ruggedness. This work provides a theoretical framework for designing and executing numerical optimization on multi-gene systems. PMID:29535690
IEEE Conference Record of 1980 Fourteenth Pulse Power Modulator Symposium, 3-5 June 1980.
1980-01-01
attachment and generation coefficients, usually given volume can control the velocity of the streamer phase as a function of E/P. Data on experimentally ...more foils could be used if desired. The mechanical design for the electron beau Experimental Program controlled switch has two competing requirenmts...deter- mine the effect of the plasma conditioning as compared to the control tests. 2W C C TABLE I: SUMMARY OF EXPERIMENTAL PROCEDURE • ur EIIEIT
Xu, Yun; Muhamadali, Howbeer; Sayqal, Ali; Dixon, Neil; Goodacre, Royston
2016-10-28
Partial least squares (PLS) is one of the most commonly used supervised modelling approaches for analysing multivariate metabolomics data. PLS is typically employed as either a regression model (PLS-R) or a classification model (PLS-DA). However, in metabolomics studies it is common to investigate multiple, potentially interacting, factors simultaneously following a specific experimental design. Such data often cannot be considered as a "pure" regression or a classification problem. Nevertheless, these data have often still been treated as a regression or classification problem and this could lead to ambiguous results. In this study, we investigated the feasibility of designing a hybrid target matrix Y that better reflects the experimental design than simple regression or binary class membership coding commonly used in PLS modelling. The new design of Y coding was based on the same principle used by structural modelling in machine learning techniques. Two real metabolomics datasets were used as examples to illustrate how the new Y coding can improve the interpretability of the PLS model compared to classic regression/classification coding.
Political Issues Skills Kit: Comparing Political Experiences, Experimental Edition.
ERIC Educational Resources Information Center
Gillespie, Judith A.; Lazarus, Stuart
Designed to be an integral part of the second-semester "Comparing Political Experiences" course, this skills kit provides supplementary student activities for four documentary "Political Issues" units. The kit is divided into three sections on skills. The analytical skill section provides exercises on six analytical skills…
Design and interpretation of cell trajectory assays
Bowden, Lucie G.; Simpson, Matthew J.; Baker, Ruth E.
2013-01-01
Cell trajectory data are often reported in the experimental cell biology literature to distinguish between different types of cell migration. Unfortunately, there is no accepted protocol for designing or interpreting such experiments and this makes it difficult to quantitatively compare different published datasets and to understand how changes in experimental design influence our ability to interpret different experiments. Here, we use an individual-based mathematical model to simulate the key features of a cell trajectory experiment. This shows that our ability to correctly interpret trajectory data is extremely sensitive to the geometry and timing of the experiment, the degree of motility bias and the number of experimental replicates. We show that cell trajectory experiments produce data that are most reliable when the experiment is performed in a quasi-one-dimensional geometry with a large number of identically prepared experiments conducted over a relatively short time-interval rather than a few trajectories recorded over particularly long time-intervals. PMID:23985736
Application of Regression-Discontinuity Analysis in Pharmaceutical Health Services Research
Zuckerman, Ilene H; Lee, Euni; Wutoh, Anthony K; Xue, Zhenyi; Stuart, Bruce
2006-01-01
Objective To demonstrate how a relatively underused design, regression-discontinuity (RD), can provide robust estimates of intervention effects when stronger designs are impossible to implement. Data Sources/Study Setting Administrative claims from a Mid-Atlantic state Medicaid program were used to evaluate the effectiveness of an educational drug utilization review intervention. Study Design Quasi-experimental design. Data Collection/Extraction Methods A drug utilization review study was conducted to evaluate a letter intervention to physicians treating Medicaid children with potentially excessive use of short-acting β2-agonist inhalers (SAB). The outcome measure is change in seasonally-adjusted SAB use 5 months pre- and postintervention. To determine if the intervention reduced monthly SAB utilization, results from an RD analysis are compared to findings from a pretest–posttest design using repeated-measure ANOVA. Principal Findings Both analyses indicated that the intervention significantly reduced SAB use among the high users. Average monthly SAB use declined by 0.9 canisters per month (p<.001) according to the repeated-measure ANOVA and by 0.2 canisters per month (p<.001) from RD analysis. Conclusions Regression-discontinuity design is a useful quasi-experimental methodology that has significant advantages in internal validity compared to other pre–post designs when assessing interventions in which subjects' assignment is based on cutoff scores for a critical variable. PMID:16584464
Experimental investigation of connection performance for prefabricated timber beam
NASA Astrophysics Data System (ADS)
Lesmana, C.; Suhendi, S.
2017-06-01
This paper presents an investigation of connection performance for a simple supported prefabricated timber beams using Meranti hardwood (Shorea sp.). The good connection is crucial for the proper functioning of the timber structures. The adequate connection condition should be assured to achieve the requirement capacity design and performance of the system. The property of material was tested according to [1]. The proposed design of bolted connections has been evaluated through experimental investigation and compared to the simple supported beam without connection. The results demonstrate the effectiveness of the proposed connection design although the ultimate load of the beam with connection is only half of the beam without connection. The test results obtained the purposed connection should be improved.
Gray, Whitney Austin; Kesten, Karen S; Hurst, Stephen; Day, Tama Duffy; Anderko, Laura
2012-01-01
The aim of this pilot study was to test design interventions such as lighting, color, and spatial color patterning on nurses' stress, alertness, and satisfaction, and to provide an example of how clinical simulation centers can be used to conduct research. The application of evidence-based design research in healthcare settings requires a transdisciplinary approach. Integrating approaches from multiple fields in real-life settings often proves time consuming and experimentally difficult. However, forums for collaboration such as clinical simulation centers may offer a solution. In these settings, identical operating and patient rooms are used to deliver simulated patient care scenarios using automated mannequins. Two identical rooms were modified in the clinical simulation center. Nurses spent 30 minutes in each room performing simulated cardiac resuscitation. Subjective measures of nurses' stress, alertness, and satisfaction were collected and compared between settings and across time using matched-pair t-test analysis. Nurses reported feeling less stressed after exposure to the experimental room than nurses who were exposed to the control room (2.22, p = .03). Scores post-session indicated a significant reduction in stress and an increase in alertness after exposure to the experimental room as compared to the control room, with significance levels below .10. (Change in stress scores: 3.44, p = .069); (change in alertness scores: 3.6, p = .071). This study reinforces the use of validated survey tools to measure stress, alertness, and satisfaction. Results support human-centered design approaches by evaluating the effect on nurses in an experimental setting.
Sarkar, Sumona; Lund, Steven P; Vyzasatya, Ravi; Vanguri, Padmavathy; Elliott, John T; Plant, Anne L; Lin-Gibson, Sheng
2017-12-01
Cell counting measurements are critical in the research, development and manufacturing of cell-based products, yet determining cell quantity with accuracy and precision remains a challenge. Validating and evaluating a cell counting measurement process can be difficult because of the lack of appropriate reference material. Here we describe an experimental design and statistical analysis approach to evaluate the quality of a cell counting measurement process in the absence of appropriate reference materials or reference methods. The experimental design is based on a dilution series study with replicate samples and observations as well as measurement process controls. The statistical analysis evaluates the precision and proportionality of the cell counting measurement process and can be used to compare the quality of two or more counting methods. As an illustration of this approach, cell counting measurement processes (automated and manual methods) were compared for a human mesenchymal stromal cell (hMSC) preparation. For the hMSC preparation investigated, results indicated that the automated method performed better than the manual counting methods in terms of precision and proportionality. By conducting well controlled dilution series experimental designs coupled with appropriate statistical analysis, quantitative indicators of repeatability and proportionality can be calculated to provide an assessment of cell counting measurement quality. This approach does not rely on the use of a reference material or comparison to "gold standard" methods known to have limited assurance of accuracy and precision. The approach presented here may help the selection, optimization, and/or validation of a cell counting measurement process. Published by Elsevier Inc.
ERIC Educational Resources Information Center
Ashworth, Kristen E.
2012-01-01
The purposes of this study were to determine the effectiveness of a vocabulary intervention for first-grade students at risk for reading and language difficulties and to compare the results of a regression discontinuity design to those of an experimental design. The specific research questions were: (1) Do first-graders who are at risk of reading…
When Theater Comes to Engineering Design: Oh How Creative They Can Be.
Pfeiffer, Ferris M; Bauer, Rachel E; Borgelt, Steve; Burgoyne, Suzanne; Grant, Sheila; Hunt, Heather K; Pardoe, Jennie J; Schmidt, David C
2017-07-01
The creative process is fun, complex, and sometimes frustrating, but it is critical to the future of our nation and progress in science, technology, engineering, mathematics (STEM), as well as other fields. Thus, we set out to see if implementing methods of active learning typical to the theater department could impact the creativity of senior capstone design students in the bioengineering (BE) department. Senior bioengineering capstone design students were allowed to self-select into groups. Prior to the beginning of coursework, all students completed a validated survey measuring engineering design self-efficacy. The control and experimental groups both received standard instruction, but in addition the experimental group received 1 h per week of creativity training developed by a theater professor. Following the semester, the students again completed the self-efficacy survey. The surveys were examined to identify differences in the initial and final self-efficacy in the experimental and control groups over the course of the semester. An analysis of variance was used to compare the experimental and control groups with p < 0.05 considered significant. Students in the experimental group reported more than a twofold (4.8 (C) versus 10.9 (E)) increase of confidence. Additionally, students in the experimental group were more motivated and less anxious when engaging in engineering design following the semester of creativity instruction. The results of this pilot study indicate that there is a significant potential to improve engineering students' creative self-efficacy through the implementation of a "curriculum of creativity" which is developed using theater methods.
Evaluation of a Low-Noise Formate Spiral-Bevel Gear Set
NASA Technical Reports Server (NTRS)
Lewicki, David g.; Woods, Ron L.; Litvin, Faydor L.; Fuentes, Alfonso
2007-01-01
Studies to evaluate low-noise Formate spiral-bevel gears were performed. Experimental tests were performed on the OH-58D helicopter main-rotor transmission in the NASA Glenn 500-hp Helicopter Transmission Test Stand. Low-noise Formate spiral-bevel gears were compared to the baseline OH-58D spiral-bevel gear design, a high-strength design, and previously tested low-noise designs (including an original low-noise design and an improved-bearing-contact low-noise design). Noise, vibration, and tooth strain tests were performed. The Formate design showed a decrease in noise and vibration compared to the baseline OH-58D design, and was similar to that of the previously tested improved-bearing contact low-noise design. The pinion tooth stresses for the Formate design significantly decreased in comparison to the baseline OH-58D design. Also similar to that of the improved bearing-contact low-noise design, the maximum stresses of the Formate design shifted toward the heel, compared to the center of the face width for the baseline, high-strength, and previously tested low-noise designs.
NASA Astrophysics Data System (ADS)
Lorenzi, M.; Mitroglou, N.; Santini, M.; Gavaises, M.
2017-03-01
An experimental technique for the estimation of the temporal-averaged vapour volume fraction within high-speed cavitating flow orifices is presented. The scientific instrument is designed to employ X-ray micro computed tomography (microCT) as a quantitative 3D measuring technique applied to custom designed, large-scale, orifice-type flow channels made from Polyether-ether-ketone (PEEK). The attenuation of the ionising electromagnetic radiation by the fluid under examination depends on its local density; the transmitted radiation through the cavitation volume is compared to the incident radiation, and combination of radiographies from sufficient number of angles leads to the reconstruction of attenuation coefficients versus the spatial position. This results to a 3D volume fraction distribution measurement of the developing multiphase flow. The experimental results obtained are compared against the high speed shadowgraph visualisation images obtained in an optically transparent nozzle with identical injection geometry; comparison between the temporal mean image and the microCT reconstruction shows excellent agreement. At the same time, the real 3D internal channel geometry (possibly eroded) has been measured and compared to the nominal manufacturing CAD drawing of the test nozzle.
Lorenzi, M; Mitroglou, N; Santini, M; Gavaises, M
2017-03-01
An experimental technique for the estimation of the temporal-averaged vapour volume fraction within high-speed cavitating flow orifices is presented. The scientific instrument is designed to employ X-ray micro computed tomography (microCT) as a quantitative 3D measuring technique applied to custom designed, large-scale, orifice-type flow channels made from Polyether-ether-ketone (PEEK). The attenuation of the ionising electromagnetic radiation by the fluid under examination depends on its local density; the transmitted radiation through the cavitation volume is compared to the incident radiation, and combination of radiographies from sufficient number of angles leads to the reconstruction of attenuation coefficients versus the spatial position. This results to a 3D volume fraction distribution measurement of the developing multiphase flow. The experimental results obtained are compared against the high speed shadowgraph visualisation images obtained in an optically transparent nozzle with identical injection geometry; comparison between the temporal mean image and the microCT reconstruction shows excellent agreement. At the same time, the real 3D internal channel geometry (possibly eroded) has been measured and compared to the nominal manufacturing CAD drawing of the test nozzle.
ERIC Educational Resources Information Center
Barhoumi, Chokri; Rossi, Pier Giuseppe
2013-01-01
The use of hypertext systems for learning and teaching complex and ill-structured domain of knowledge has been attracting attention in design of instruction. In this context, an experimental research has been conducted to explore the effectiveness of instructional design oriented hypertext systems. Cognitive flexibility hypertext theory is…
Introducing Science Experiments to Rote-Learning Classes in Pakistani Middle Schools
ERIC Educational Resources Information Center
Pell, Anthony William; Iqbal, Hafiz Muhammad; Sohail, Shahida
2010-01-01
A mixed-methods sequential research design has been used to test the effect of introducing teacher science demonstrations to a traditional book-learning sample of 384 Grade 7 boys and girls from five schools in Lahore, Pakistan. In the quasi-experimental quantitative study, the eight classes of comparable ability were designated either…
2017-01-23
of classification technologies for Munitions Response (MR). This demonstration was designed to evaluate advanced classification methodology at the...advanced electromagnetic induction sensors and static, cued surveys to classify anomalies as either targets of interest (TOI) or non -TOI. Static data...17 5.1 Conceptual Experimental Design
77 FR 17065 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-23
... comparison communities will enable use of a quasi-experimental, baseline and follow-up study design for... are no studies that have examined the impact of smoke free policies by comparing pre- and post SHS... Patient Protection and Affordable Care Act, which is designed to expand and sustain the necessary...
ERIC Educational Resources Information Center
Kuwik, Paul David
The purpose of the study was to determine whether exposing junior high school students to a unit on design in construction technology and to a unit on design in manufacturing technology significantly affects their achievement on a test measuring "Technological Principles of Design" when compared to a group of junior high school students exposed…
Issues and recent advances in optimal experimental design for site investigation (Invited)
NASA Astrophysics Data System (ADS)
Nowak, W.
2013-12-01
This presentation provides an overview over issues and recent advances in model-based experimental design for site exploration. The addressed issues and advances are (1) how to provide an adequate envelope to prior uncertainty, (2) how to define the information needs in a task-oriented manner, (3) how to measure the expected impact of a data set that it not yet available but only planned to be collected, and (4) how to perform best the optimization of the data collection plan. Among other shortcomings of the state-of-the-art, it is identified that there is a lack of demonstrator studies where exploration schemes based on expert judgment are compared to exploration schemes obtained by optimal experimental design. Such studies will be necessary do address the often voiced concern that experimental design is an academic exercise with little improvement potential over the well- trained gut feeling of field experts. When addressing this concern, a specific focus has to be given to uncertainty in model structure, parameterizations and parameter values, and to related surprises that data often bring about in field studies, but never in synthetic-data based studies. The background of this concern is that, initially, conceptual uncertainty may be so large that surprises are the rule rather than the exception. In such situations, field experts have a large body of experience in handling the surprises, and expert judgment may be good enough compared to meticulous optimization based on a model that is about to be falsified by the incoming data. In order to meet surprises accordingly and adapt to them, there needs to be a sufficient representation of conceptual uncertainty within the models used. Also, it is useless to optimize an entire design under this initial range of uncertainty. Thus, the goal setting of the optimization should include the objective to reduce conceptual uncertainty. A possible way out is to upgrade experimental design theory towards real-time interaction with the ongoing site investigation, such that surprises in the data are immediately accounted for to restrict the conceptual uncertainty and update the optimization of the plan.
PBL-GIS in Secondary Geography Education: Does It Result in Higher-Order Learning Outcomes?
ERIC Educational Resources Information Center
Liu, Yan; Bui, Elisabeth N.; Chang, Chew-Hung; Lossman, Hans G.
2010-01-01
This article presents research on evaluating problem-based learning using GIS technology in a Singapore secondary school. A quasi-experimental research design was carried to test the PBL pedagogy (PBL-GIS) with an experimental group of students and compare their learning outcomes with a control group who were exposed to PBL but not GIS. The…
ERIC Educational Resources Information Center
Shamuganathana, Sheila; Karpudewan, Mageswary
2017-01-01
Existing studies report on the importance of instilling environmental literacy among students from an early stage of schooling to enable them to adopt more pro-environmental behaviors in the near future. This quasi-experimental study was designed to compare the level of environmental literacy among two groups of students: the experimental group (N…
The use of clinical trials in comparative effectiveness research on mental health
Blanco, Carlos; Rafful, Claudia; Olfson, Mark
2013-01-01
Objectives A large body of research on comparative effectiveness research (CER) focuses on the use of observational and quasi-experimental approaches. We sought to examine the use of clinical trials as a tool for CER, particularly in mental health. Study Design and Setting Examination of three ongoing randomized clinical trials in psychiatry that address issues which would pose difficulties for non-experimental CER methods. Results Existing statistical approaches to non-experimental data appear insufficient to compensate for biases that may arise when the pattern of missing data cannot be properly modeled such as when there are no standards for treatment, when affected populations have limited access to treatment, or when there are high rates of treatment dropout. Conclusions Clinical trials should retain an important role in CER, particularly in cases of high disorder prevalence, large expected effect sizes, difficult to reach populations or when examining sequential treatments or stepped-care algorithms. Progress in CER in mental health will require careful consideration of appropriate selection between clinical trials and non-experimental designs and on allocation of research resources to optimally inform key treatment decisions for each individual patient. PMID:23849150
Efficient experimental design of high-fidelity three-qubit quantum gates via genetic programming
NASA Astrophysics Data System (ADS)
Devra, Amit; Prabhu, Prithviraj; Singh, Harpreet; Arvind; Dorai, Kavita
2018-03-01
We have designed efficient quantum circuits for the three-qubit Toffoli (controlled-controlled-NOT) and the Fredkin (controlled-SWAP) gate, optimized via genetic programming methods. The gates thus obtained were experimentally implemented on a three-qubit NMR quantum information processor, with a high fidelity. Toffoli and Fredkin gates in conjunction with the single-qubit Hadamard gates form a universal gate set for quantum computing and are an essential component of several quantum algorithms. Genetic algorithms are stochastic search algorithms based on the logic of natural selection and biological genetics and have been widely used for quantum information processing applications. We devised a new selection mechanism within the genetic algorithm framework to select individuals from a population. We call this mechanism the "Luck-Choose" mechanism and were able to achieve faster convergence to a solution using this mechanism, as compared to existing selection mechanisms. The optimization was performed under the constraint that the experimentally implemented pulses are of short duration and can be implemented with high fidelity. We demonstrate the advantage of our pulse sequences by comparing our results with existing experimental schemes and other numerical optimization methods.
Lee, Jae-Won; Lim, Se-Ho; Kim, Moon-Key; Kang, Sang-Hoon
2015-12-01
We examined the precision of a computer-aided design/computer-aided manufacturing-engineered, manufactured, facebow-based surgical guide template (facebow wafer) by comparing it with a bite splint-type orthognathic computer-aided design/computer-aided manufacturing-engineered surgical guide template (bite wafer). We used 24 rapid prototyping (RP) models of the craniofacial skeleton with maxillary deformities. Twelve RP models each were used for the facebow wafer group and the bite wafer group (experimental group). Experimental maxillary orthognathic surgery was performed on the RP models of both groups. Errors were evaluated through comparisons with surgical simulations. We measured the minimum distances from 3 planes of reference to determine the vertical, lateral, and anteroposterior errors at specific measurement points. The measured errors were compared between experimental groups using a t test. There were significant intergroup differences in the lateral error when we compared the absolute values of the 3-D linear distance, as well as vertical, lateral, and anteroposterior errors between experimental groups. The bite wafer method exhibited little lateral error overall and little error in the anterior tooth region. The facebow wafer method exhibited very little vertical error in the posterior molar region. The clinical precision of the facebow wafer method did not significantly exceed that of the bite wafer method. Copyright © 2015 Elsevier Inc. All rights reserved.
A Comparative Study of Exact versus Propensity Matching Techniques Using Monte Carlo Simulation
ERIC Educational Resources Information Center
Itang'ata, Mukaria J. J.
2013-01-01
Often researchers face situations where comparative studies between two or more programs are necessary to make causal inferences for informed policy decision-making. Experimental designs employing randomization provide the strongest evidence for causal inferences. However, many pragmatic and ethical challenges may preclude the use of randomized…
Human Cadavers vs. Multimedia Simulation: A Study of Student Learning in Anatomy
ERIC Educational Resources Information Center
Saltarelli, Andrew J.; Roseth, Cary J.; Saltarelli, William A.
2014-01-01
Multimedia and simulation programs are increasingly being used for anatomy instruction, yet it remains unclear how learning with these technologies compares with learning with actual human cadavers. Using a multilevel, quasi-experimental-control design, this study compared the effects of "Anatomy and Physiology Revealed" (APR) multimedia…
Integrating Symmetry in Stereochemical Analysis in Introductory Organic Chemistry
ERIC Educational Resources Information Center
Taagepera, Mare; Arasasingham, Ramesh D.; King, Susan; Potter, Frank; Martorell, Ingrid; Ford, David; Wu, Jason; Kearney, Aaron M.
2011-01-01
We report a comparative study using "knowledge space theory" (KAT) to assess the impact of a hands-on laboratory exercise that used molecular model kits to emphasize the connections between a plane of symmetry, Charity, and isomerism in an introductory organic chemistry course. The experimental design compared three groups of…
System Identification of a Heaving Point Absorber: Design of Experiment and Device Modeling
Bacelli, Giorgio; Coe, Ryan; Patterson, David; ...
2017-04-01
Empirically based modeling is an essential aspect of design for a wave energy converter. These models are used in structural, mechanical and control design processes, as well as for performance prediction. The design of experiments and methods used to produce models from collected data have a strong impact on the quality of the model. This study considers the system identification and model validation process based on data collected from a wave tank test of a model-scale wave energy converter. Experimental design and data processing techniques based on general system identification procedures are discussed and compared with the practices often followedmore » for wave tank testing. The general system identification processes are shown to have a number of advantages. The experimental data is then used to produce multiple models for the dynamics of the device. These models are validated and their performance is compared against one and other. Furthermore, while most models of wave energy converters use a formulation with wave elevation as an input, this study shows that a model using a hull pressure sensor to incorporate the wave excitation phenomenon has better accuracy.« less
System Identification of a Heaving Point Absorber: Design of Experiment and Device Modeling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bacelli, Giorgio; Coe, Ryan; Patterson, David
Empirically based modeling is an essential aspect of design for a wave energy converter. These models are used in structural, mechanical and control design processes, as well as for performance prediction. The design of experiments and methods used to produce models from collected data have a strong impact on the quality of the model. This study considers the system identification and model validation process based on data collected from a wave tank test of a model-scale wave energy converter. Experimental design and data processing techniques based on general system identification procedures are discussed and compared with the practices often followedmore » for wave tank testing. The general system identification processes are shown to have a number of advantages. The experimental data is then used to produce multiple models for the dynamics of the device. These models are validated and their performance is compared against one and other. Furthermore, while most models of wave energy converters use a formulation with wave elevation as an input, this study shows that a model using a hull pressure sensor to incorporate the wave excitation phenomenon has better accuracy.« less
Tracer tomography: design concepts and field experiments using heat as a tracer.
Doro, Kennedy O; Cirpka, Olaf A; Leven, Carsten
2015-04-01
Numerical and laboratory studies have provided evidence that combining hydraulic tomography with tomographic tracer tests could improve the estimation of hydraulic conductivity compared with using hydraulic data alone. Field demonstrations, however, have been lacking so far, which we attribute to experimental difficulties. In this study, we present a conceptual design and experimental applications of tracer tomography at the field scale using heat as a tracer. In our experimental design, we improve active heat tracer testing by minimizing possible effects of heat losses, buoyancy, viscosity, and changing boundary conditions. We also utilize a cost-effective approach of measuring temperature changes in situ at high resolution. We apply the presented method to the 8 m thick heterogeneous, sandy gravel, alluvial aquifer at the Lauswiesen Hydrogeological Research Site in Tübingen, Germany. Results of our tomographic heat-tracer experiments are in line with earlier work on characterizing the aquifer at the test site. We demonstrate from the experimental perspective that tracer tomography is applicable and suitable at the field scale using heat as a tracer. The experimental results also demonstrate the potential of heat-tracer tomography as a cost-effective means for characterizing aquifer heterogeneity. © 2014, National Ground Water Association.
NASA Technical Reports Server (NTRS)
Weilmuenster, K. J.; Hamilton, H. H., II
1983-01-01
A computer code HALIS, designed to compute the three dimensional flow about shuttle like configurations at angles of attack greater than 25 deg, is described. Results from HALIS are compared where possible with an existing flow field code; such comparisons show excellent agreement. Also, HALIS results are compared with experimental pressure distributions on shuttle models over a wide range of angle of attack. These comparisons are excellent. It is demonstrated that the HALIS code can incorporate equilibrium air chemistry in flow field computations.
Morrison, William R.; Cullum, John P.; Leskey, Tracy C.
2015-01-01
Halyomorpha halys (Stål) is an invasive pest that attacks numerous crops. For growers to make informed management decisions against H. halys, an effective monitoring tool must be in place. We evaluated various trap designs baited with the two-component aggregation pheromone of H. halys and synergist and deployed in commercial apple orchards. We compared our current experimental standard trap, a black plywood pyramid trap 1.22 m in height deployed between border row apple trees with other trap designs for two growing seasons. These included a black lightweight coroplast pyramid trap of similar dimension, a smaller (29 cm) pyramid trap also ground deployed, a smaller limb-attached pyramid trap, a smaller pyramid trap hanging from a horizontal branch, and a semipyramid design known as the Rescue trap. We found that the coroplast pyramid was the most sensitive, capturing more adults than all other trap designs including our experimental standard. Smaller pyramid traps performed equally in adult captures to our experimental standard, though nymphal captures were statistically lower for the hanging traps. Experimental standard plywood and coroplast pyramid trap correlations were strong, suggesting that standard plywood pyramid traps could be replaced with lighter, cheaper coroplast pyramid traps. Strong correlations with small ground- and limb-deployed pyramid traps also suggest that these designs offer promise as well. Growers may be able to adopt alternative trap designs that are cheaper, lighter, and easier to deploy to monitor H. halys in orchards without a significant loss in sensitivity. PMID:26470309
Knowledge synthesis with maps of neural connectivity.
Tallis, Marcelo; Thompson, Richard; Russ, Thomas A; Burns, Gully A P C
2011-01-01
This paper describes software for neuroanatomical knowledge synthesis based on neural connectivity data. This software supports a mature methodology developed since the early 1990s. Over this time, the Swanson laboratory at USC has generated an account of the neural connectivity of the sub-structures of the hypothalamus, amygdala, septum, hippocampus, and bed nucleus of the stria terminalis. This is based on neuroanatomical data maps drawn into a standard brain atlas by experts. In earlier work, we presented an application for visualizing and comparing anatomical macro connections using the Swanson third edition atlas as a framework for accurate registration. Here we describe major improvements to the NeuARt application based on the incorporation of a knowledge representation of experimental design. We also present improvements in the interface and features of the data mapping components within a unified web-application. As a step toward developing an accurate sub-regional account of neural connectivity, we provide navigational access between the data maps and a semantic representation of area-to-area connections that they support. We do so based on an approach called "Knowledge Engineering from Experimental Design" (KEfED) model that is based on experimental variables. We have extended the underlying KEfED representation of tract-tracing experiments by incorporating the definition of a neuronanatomical data map as a measurement variable in the study design. This paper describes the software design of a web-application that allows anatomical data sets to be described within a standard experimental context and thus indexed by non-spatial experimental design features.
Innovation ability and innovation spirit in photoelectric comprehensive experiment teaching
NASA Astrophysics Data System (ADS)
Wang, Dexing; Zhang, Yang; Wang, Xiaofeng; Zhang, Xiaojun; Zhang, Tao; Sun, Peng
2017-08-01
The traditional experimental teaching methods have some shortcomings in the training the student innovation ability. In order to improve the student practical ability in the photoelectric technology, in this paper new experimental teaching modes are tried and reformed for cultivating the innovative ability of students in the linear CCD experiment. The photoelectric experiment systems are independently designed and completed by students. Compared with the traditional experimental teaching methods, this new methods have a great role in the development of the ability of creative thinking.
Design, Optimization and Evaluation of Integrally Stiffened Al 7050 Panel with Curved Stiffeners
NASA Technical Reports Server (NTRS)
Slemp, Wesley C. H.; Bird, R. Keith; Kapania, Rakesh K.; Havens, David; Norris, Ashley; Olliffe, Robert
2011-01-01
A curvilinear stiffened panel was designed, manufactured, and tested in the Combined Load Test Fixture at NASA Langley Research Center. The panel was optimized for minimum mass subjected to constraints on buckling load, yielding, and crippling or local stiffener failure using a new analysis tool named EBF3PanelOpt. The panel was designed for a combined compression-shear loading configuration that is a realistic load case for a typical aircraft wing panel. The panel was loaded beyond buckling and strains and out-of-plane displacements were measured. The experimental data were compared with the strains and out-of-plane deflections from a high fidelity nonlinear finite element analysis and linear elastic finite element analysis of the panel/test-fixture assembly. The numerical results indicated that the panel buckled at the linearly elastic buckling eigenvalue predicted for the panel/test-fixture assembly. The experimental strains prior to buckling compared well with both the linear and nonlinear finite element model.
NASA Technical Reports Server (NTRS)
Madan, Ram C.; Shuart, Mark J.
1990-01-01
Blade-stiffened, compression-loaded cover panels were designed, manufactured, analyzed, and tested. All panels were fabricated from IM6/1808I interleafed graphite-epoxy. An orthotropic blade stiffener and an orthotropic skin were selected to satisfy the design requirements for an advanced aircraft configuration. All specimens were impact damaged prior to testing. Experimental results were obtained for three- and five-stiffener panels. Analytical results described interlaminar forces caused by impact and predicted specimen residual strength. The analytical results compared reasonably with the experimental results for residual strength of the specimens.
NASA Astrophysics Data System (ADS)
Tumewu, Widya Anjelia; Wulan, Ana Ratna; Sanjaya, Yayan
2017-05-01
The purpose of this study was to know comparing the effectiveness of learning using Project-based learning (PjBL) and Discovery Learning (DL) toward students metacognitive strategies on global warming concept. A quasi-experimental research design with a The Matching-Only Pretest-Posttest Control Group Design was used in this study. The subjects were students of two classes 7th grade of one of junior high school in Bandung City, West Java of 2015/2016 academic year. The study was conducted on two experimental class, that were project-based learning treatment on the experimental class I and discovery learning treatment was done on the experimental class II. The data was collected through questionnaire to know students metacognitive strategies. The statistical analysis showed that there were statistically significant differences in students metacognitive strategies between project-based learning and discovery learning.
Stürmer, Til; Wyss, Richard; Glynn, Robert J.; Brookhart, M. Alan
2014-01-01
Treatment effects, especially when comparing two or more therapeutic alternatives as in comparative effectiveness research, are likely to be heterogeneous across age, gender, co-morbidities, and co-medications. Propensity scores (PSs), an alternative to multivariable outcome models to control for measured confounding, have specific advantages in the presence of heterogeneous treatment effects. Implementing PSs using matching or weighting allows us to estimate different overall treatment effects in differently defined populations. Heterogeneous treatment effects can also be due to unmeasured confounding concentrated in those treated contrary to prediction. Sensitivity analyses based on PSs can help to assess such unmeasured confounding. PSs should be considered a primary or secondary analytic strategy in non-experimental medical research, including pharmacoepidemiology and non-experimental comparative effectiveness research. PMID:24520806
Experimental Characterization of Piezoelectric Radial Field Diaphragms for Fluidic Control
NASA Technical Reports Server (NTRS)
Bryant, R. G.; Kavli, S. E.; Thomas, R. A., Jr.; Darji, K. J.; Mossi, K. M.
2004-01-01
NASA has recently developed a new piezoelectric actuator, the Radial Field Diaphragm or RFD. This actuator uses a radially-directed electric field to generate concentric out-of-plane (Z-axis) motion that allows this packaged device to be used as a pump or valve diaphragm. In order to efficiently use this new active device, experimental determination of pressure, flow rate, mechanical work, power consumption and overall efficiency needs to be determined by actually building a pump. However, without an optimized pump design, it is difficult to assess the quality of the data, as these results are inherent to the actual pump. Hence, separate experiments must be conducted in order to generate independent results to help guide the design criteria and pump quality. This paper focuses on the experiments used to generate the RFD's operational parameters and then compares these results to the experimentally determined results of several types of ball pumps. Also discussed are how errors are inherently introduced into the experiments, the pump design, experimental hardware and their effects on the overall system efficiency.
1992-05-12
compared to an untested one. The quasi-experinmtal design with nonequivalent comparison groups included leadership training between pre and posttests...experimental, pretest-posttest, nonequivalent comparison groups (Wave A & Wave B) design . It allowed investigation of the influence of leadership training on...provided comparison groups . According to Burns and Grove (1987), pretest-posttest designs have inherent threats to validity. Pretest administration
Experimental validation of ultra-thin metalenses for N-beam emissions based on transformation optics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Kuang, E-mail: zhangkuang@hit.edu.cn; State Key Laboratory of Millimeter Waves, Nanjing 210096; Ding, Xumin
2016-02-01
A general design of metalenses for N-beam emissions is proposed based on transformation optics. A linear mapping function is adopted to achieve the homogeneous characterization of the transforming medium, which is therefore easy to be achieved compared with previous designs limited by inhomogeneity based on transformation optics. To verify the theoretical design, a four-beam antenna constructed with ultrathin, homogenous, and uniaxial anisotropic metalens is designed, fabricated, and measured. It is shown that the realized gain of the four-beam antenna is increased by 6 dB compared with the single dipole source, while working frequency and relative bandwidth are kept unchanged. The measuredmore » far-field pattern verifies theoretical design procedure.« less
Production of footbridge with double curvature made of UHPC
NASA Astrophysics Data System (ADS)
Kolísko, J.; Čítek, D.; Tej, P.; Rydval, M.
2017-09-01
This article present a mix design, preparation and production of thin-walled footbridge made from UHPFRC. In this case an experimental pedestrian bridge was design and prepared. Bridge with span of 10 m and the clear width of 1.50 m designed as single-span bridge. Optimization of UHPFRC matrix and parameters of this material leads to the design of very thin structures. Total thickness of shell structure 30 - 45 mm. Bridge was cast as a prefabricated element in one piece. Self-compacting character of UHPFRC with high flowability allows the production of the final structure. Extensive research was done before production of footbridge. Experimental reached data were compared with extensive numerical analysis and the final design of structure and UHPFRC matrix were optimized in many details. Two versions of large scale mock-ups were casted and tested. According to the complexity of whole experiment a casting technology and production of formwork were tested and optimized many times.
A new optimal sliding mode controller design using scalar sign function.
Singla, Mithun; Shieh, Leang-San; Song, Gangbing; Xie, Linbo; Zhang, Yongpeng
2014-03-01
This paper presents a new optimal sliding mode controller using the scalar sign function method. A smooth, continuous-time scalar sign function is used to replace the discontinuous switching function in the design of a sliding mode controller. The proposed sliding mode controller is designed using an optimal Linear Quadratic Regulator (LQR) approach. The sliding surface of the system is designed using stable eigenvectors and the scalar sign function. Controller simulations are compared with another existing optimal sliding mode controller. To test the effectiveness of the proposed controller, the controller is implemented on an aluminum beam with piezoceramic sensor and actuator for vibration control. This paper includes the control design and stability analysis of the new optimal sliding mode controller, followed by simulation and experimental results. The simulation and experimental results show that the proposed approach is very effective. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.
New technology in turbine aerodynamics.
NASA Technical Reports Server (NTRS)
Glassman, A. J.; Moffitt, T. P.
1972-01-01
Cursory review of some recent work that has been done in turbine aerodynamic research. Topics discussed include the aerodynamic effect of turbine coolant, high work-factor (ratio of stage work to square of blade speed) turbines, and computer methods for turbine design and performance prediction. Experimental cooled-turbine aerodynamics programs using two-dimensional cascades, full annular cascades, and cold rotating turbine stage tests are discussed with some typical results presented. Analytically predicted results for cooled blade performance are compared to experimental results. The problems and some of the current programs associated with the use of very high work factors for fan-drive turbines of high-bypass-ratio engines are discussed. Computer programs have been developed for turbine design-point performance, off-design performance, supersonic blade profile design, and the calculation of channel velocities for subsonic and transonic flowfields. The use of these programs for the design and analysis of axial and radial turbines is discussed.
Design of a Smart Ultrasonic Transducer for Interconnecting Machine Applications
Yan, Tian-Hong; Wang, Wei; Chen, Xue-Dong; Li, Qing; Xu, Chang
2009-01-01
A high-frequency ultrasonic transducer for copper or gold wire bonding has been designed, analyzed, prototyped and tested. Modeling techniques were used in the design phase and a practical design procedure was established and used. The transducer was decomposed into its elementary components. For each component, an initial design was obtained with simulations using a finite elements model (FEM). Simulated ultrasonic modules were built and characterized experimentally through the Laser Doppler Vibrometer (LDV) and electrical resonance spectra. Compared with experimental data, the FEM could be iteratively adjusted and updated. Having achieved a remarkably highly-predictive FEM of the whole transducer, the design parameters could be tuned for the desired applications, then the transducer is fixed on the wire bonder with a complete holder clamping was calculated by the FEM. The approach to mount ultrasonic transducers on wire bonding machines also is of major importance for wire bonding in modern electronic packaging. The presented method can lead to obtaining a nearly complete decoupling clamper design of the transducer to the wire bonder. PMID:22408564
Factorial experiments: efficient tools for evaluation of intervention components.
Collins, Linda M; Dziak, John J; Kugler, Kari C; Trail, Jessica B
2014-10-01
An understanding of the individual and combined effects of a set of intervention components is important for moving the science of preventive medicine interventions forward. This understanding can often be achieved in an efficient and economical way via a factorial experiment, in which two or more independent variables are manipulated. The factorial experiment is a complement to the RCT; the two designs address different research questions. To offer an introduction to factorial experiments aimed at investigators trained primarily in the RCT. The factorial experiment is compared and contrasted with other experimental designs used commonly in intervention science to highlight where each is most efficient and appropriate. Several points are made: factorial experiments make very efficient use of experimental subjects when the data are properly analyzed; a factorial experiment can have excellent statistical power even if it has relatively few subjects per experimental condition; and when conducting research to select components for inclusion in a multicomponent intervention, interactions should be studied rather than avoided. Investigators in preventive medicine and related areas should begin considering factorial experiments alongside other approaches. Experimental designs should be chosen from a resource management perspective, which states that the best experimental design is the one that provides the greatest scientific benefit without exceeding available resources. Copyright © 2014 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Experiments and Analyses of Distributed Exhaust Nozzles
NASA Technical Reports Server (NTRS)
Kinzie, Kevin W.; Schein, David B.; Solomon, W. David, Jr.
2002-01-01
Experimental and analytical aeroacoustic properties of several distributed exhaust nozzle (DEN) designs are presented. Significant differences between the designs are observed and correlated back to Computational Fluid Dynamics (CFD) flowfield predictions. Up to 20 dB of noise reduction on a spectral basis and 10 dB on an overall sound pressure level basis are demonstrated from the DEN designs compared to a round reference nozzle. The most successful DEN designs acoustically show a predicted thrust loss of approximately 10% compared to the reference nozzle. Characteristics of the individual mini-jet nozzles that comprise the DEN such as jet-jet shielding and coalescence are shown to play a major role in the noise signature.
True and Quasi-Experimental Designs. ERIC/AE Digest.
ERIC Educational Resources Information Center
Gribbons, Barry; Herman, Joan
Among the different types of experimental design are two general categories: true experimental designs and quasi- experimental designs. True experimental designs include more than one purposively created group, common measured outcomes, and random assignment. Quasi-experimental designs are commonly used when random assignment is not practical or…
ERIC Educational Resources Information Center
Forehand, Michael Joshua
2014-01-01
A quasi-experimental, pre-test post-test nonequivalent control group study was utilized to determine the difference in students' perceived learning, attitudes toward school, and achievement when participating in classes utilizing engagement design qualities as compared to students in classes not utilizing engagement design qualities. To inform the…
DOT National Transportation Integrated Search
2006-04-14
This report presents the results of the national evaluation of the South Lake Tahoe coordinated Transit System (CTS) Project. The CTS Project involved combining transit services offered by private and public sector stakeholders in South Lake Tahoe in...
An Evaluation of a Worksite Exercise Intervention Using the Social Cognitive Theory: A Pilot Study
ERIC Educational Resources Information Center
Amaya, Megan; Petosa, R. L.
2012-01-01
Purpose: To increase exercise adherence among insufficiently active adult employees. Design: A quasi-experimental separate samples pre-test-post-test group design was used to compare treatment and comparison group. Setting: The worksite. Subjects: Employees (n = 127) who did not meet current American College of Sports Medicine (ACSM)…
ERIC Educational Resources Information Center
Deegan, Donna; Wims, Padraig; Pettit, Tony
2016-01-01
Purpose: In this article the use of blended learning multimedia materials as an education tool was compared with the traditional approach for skills training. Design/Methodology/Approach: This study was conducted in Ireland using a pre-test, post-test experimental design. All students were instructed on how to complete two skills using either a…
ERIC Educational Resources Information Center
Wisecup, Allison K.; Grady, Dennis; Roth, Richard A.; Stephens, Julio
2017-01-01
Purpose: The purpose of this study was to determine whether, and how, electricity consumption by students in university residence halls were impacted through three intervention strategies. Design/methodology/approach: The current investigation uses a quasi-experimental design by exposing freshman students in four matched residence halls and the…
Impact of an Inquiry Unit on Grade 4 Students' Science Learning
ERIC Educational Resources Information Center
Di Mauro, María Florencia; Furman, Melina
2016-01-01
This paper concerns the identification of teaching strategies that enhance the development of 4th grade students' experimental design skills at a public primary school in Argentina. Students' performance in the design of relevant experiments was evaluated before and after an eight-week intervention compared to a control group, as well as the…
ERIC Educational Resources Information Center
Lovett, Sadie; Rehfeldt, Ruth Anne; Garcia, Yors; Dunning, Johnna
2011-01-01
This study compared the effects of a computer-based stimulus equivalence protocol to a traditional lecture format in teaching single-subject experimental design concepts to undergraduate students. Participants were assigned to either an equivalence or a lecture group, and performance on a paper-and-pencil test that targeted relations among the…
Impact of Adult Day Services on Behavioral and Psychological Symptoms of Dementia
ERIC Educational Resources Information Center
Femia, Elia E.; Zarit, Steven H.; Stephens, Mary Ann Parris; Greene, Rick
2007-01-01
Purpose: This study explored whether adult day service (ADS) use was associated with reductions in behavioral and psychological symptoms of dementia (BPSD) in individuals with dementia. Design and Methods: We used a quasi-experimental design to compare a group of 133 persons with dementia (PWDs) who initially enrolled in an ADS program to a…
ERIC Educational Resources Information Center
Kara, Yilmaz; Yesilyurt, Selami
2008-01-01
The purpose of this study was to investigate the effects of tutorial and edutainment design of instructional software programs related to the "cell division" topic on student achievements, misconceptions and attitudes. An experimental research design including the cell division achievement test (CAT), the cell division concept test (CCT) and…
Reconciled Rat and Human Metabolic Networks for Comparative Toxicogenomics and Biomarker Predictions
2017-02-08
compared with the original human GPR rules (Supplementary Fig. 3). The consensus-based approach for filtering orthology annotations was designed to...ARTICLE Received 29 Jan 2016 | Accepted 13 Dec 2016 | Published 8 Feb 2017 Reconciled rat and human metabolic networks for comparative toxicogenomics...predictions in response to 76 drugs. We validate comparative predictions for xanthine derivatives with new experimental data and literature- based evidence
ERIC Educational Resources Information Center
Bot, Thomas D.; Eze, John E.
2016-01-01
This article presents the findings from an experimental study on the effectiveness of concept mapping and cooperative learning strategies on SSII students' achievement in trigonometry in mathematics. The research design used in conducting the study was quasi-experimental pre-test and post-test non-equivalent control group. The sample consisted of…
ERIC Educational Resources Information Center
Sahin, Semsettin M. S.; Baturay, Meltem Huri
2016-01-01
The purpose of this research study is to investigate the effect of the 5E-learning model supported with WebQuest media on the achievement and satisfaction of students. Therefore, two groups of students were compared in an experimental research design model. The experimental group was exposed to the 5E-learning model supported with WebQuest media;…
ERIC Educational Resources Information Center
Kaya, Osman Nafiz; Dogan, Alev; Gokcek, Nur; Kilic, Ziya; Kilic, Esma
2007-01-01
The purpose of this study was to investigate the effects of multiple intelligences (MI) teaching approach on 8th Grade students' achievement in and attitudes toward science. This study used a pretest-posttest control group experimental design. While the experimental group (n=30) was taught a unit on acids and bases using MI teaching approach, the…
Model validations for low-global warming potential refrigerants in mini-split air-conditioning units
Shen, Bo; Shrestha, Som; Abdelaziz, Omar
2016-09-02
To identify low GWP (global warming potential) refrigerants to replace R-22 and R-410A, extensive experimental evaluations were conducted for multiple candidates of refrigerant at the standard test conditions and at high-ambient conditions with outdoor temperature varying from 27.8 C to 55.0 C.. In the study, R-22 was compared to propane (R-290), DR-3, ARM-20B, N-20B and R-444B in a mini-split air conditioning unit originally designed for R-22; R-410A was compared to R-32, DR-55, ARM-71A, L41-2 (R-447A) in a mini-split unit designed for R-410A. To reveal physics behind the measured performance results, thermodynamic properties of the alternative refrigerants were analysed. In addition,more » the experimental data was used to calibrate a physics-based equipment model, i.e. ORNL Heat Pump Design Model (HPDM). The calibrated model translated the experimental results to key calculated parameters, i.e. compressor efficiencies, refrigerant side two-phase heat transfer coefficients, corresponding to each refrigerant. As a result, these calculated values provide scientific insights on the performance of the alternative refrigerants and are useful for other applications beyond mini-split air conditioning units.« less
Model validations for low-global warming potential refrigerants in mini-split air-conditioning units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Bo; Shrestha, Som; Abdelaziz, Omar
To identify low GWP (global warming potential) refrigerants to replace R-22 and R-410A, extensive experimental evaluations were conducted for multiple candidates of refrigerant at the standard test conditions and at high-ambient conditions with outdoor temperature varying from 27.8 C to 55.0 C.. In the study, R-22 was compared to propane (R-290), DR-3, ARM-20B, N-20B and R-444B in a mini-split air conditioning unit originally designed for R-22; R-410A was compared to R-32, DR-55, ARM-71A, L41-2 (R-447A) in a mini-split unit designed for R-410A. To reveal physics behind the measured performance results, thermodynamic properties of the alternative refrigerants were analysed. In addition,more » the experimental data was used to calibrate a physics-based equipment model, i.e. ORNL Heat Pump Design Model (HPDM). The calibrated model translated the experimental results to key calculated parameters, i.e. compressor efficiencies, refrigerant side two-phase heat transfer coefficients, corresponding to each refrigerant. As a result, these calculated values provide scientific insights on the performance of the alternative refrigerants and are useful for other applications beyond mini-split air conditioning units.« less
Rapid repair of severely earthquake-damaged bridge piers with flexural-shear failure mode
NASA Astrophysics Data System (ADS)
Sun, Zhiguo; Wang, Dongsheng; Du, Xiuli; Si, Bingjun
2011-12-01
An experimental study was conducted to investigate the feasibility of a proposed rapid repair technique for severely earthquake-damaged bridge piers with flexural-shear failure mode. Six circular pier specimens were first tested to severe damage in flexural-shear mode and repaired using early-strength concrete with high-fluidity and carbon fiber reinforced polymers (CFRP). After about four days, the repaired specimens were tested to failure again. The seismic behavior of the repaired specimens was evaluated and compared to the original specimens. Test results indicate that the proposed repair technique is highly effective. Both shear strength and lateral displacement of the repaired piers increased when compared to the original specimens, and the failure mechanism of the piers shifted from flexural-shear failure to ductile flexural failure. Finally, a simple design model based on the Seible formulation for post-earthquake repair design was compared to the experimental results. It is concluded that the design equation for bridge pier strengthening before an earthquake could be applicable to seismic repairs after an earthquake if the shear strength contribution of the spiral bars in the repaired piers is disregarded and 1.5 times more FRP sheets is provided.
Computational Design of a Krueger Flap Targeting Conventional Slat Aerodynamics
NASA Technical Reports Server (NTRS)
Akaydin, H. Dogus; Housman, Jeffrey A.; Kiris, Cetin C.; Bahr, Christopher J.; Hutcheson, Florence V.
2016-01-01
In this study, we demonstrate the design of a Krueger flap as a substitute for a conventional slat in a high-lift system. This notional design, with the objective of matching equivalent-mission performance on aircraft approach, was required for a comparative aeroacoustic study with computational and experimental components. We generated a family of high-lift systems with Krueger flaps based on a set of design parameters. Then, we evaluated the high-lift systems using steady 2D RANS simulations to find a good match for the conventional slat, based on total lift coefficients in free-air. Finally, we evaluated the mean aerodynamics of the high-lift systems with Krueger flap and conventional slat as they were installed in an open-jet wind tunnel flow. The surface pressures predicted with the simulations agreed well with experimental results.
NASA Technical Reports Server (NTRS)
Oliver, W. R.
1980-01-01
The development of an advanced technology high lift system for an energy efficient transport incorporating a high aspect ratio supercritical wing is described. This development is based on the results of trade studies to select the high lift system, analysis techniques utilized to design the high lift system, and results of a wind tunnel test program. The program included the first experimental low speed, high Reynolds number wind tunnel test for this class of aircraft. The experimental results include the effects on low speed aerodynamic characteristics of various leading and trailing edge devices, nacelles and pylons, aileron, spoilers, and Mach and Reynolds numbers. Results are discussed and compared with the experimental data and the various aerodynamic characteristics are estimated.
Impact of an inquiry unit on grade 4 students' science learning
NASA Astrophysics Data System (ADS)
Di Mauro, María Florencia; Furman, Melina
2016-09-01
This paper concerns the identification of teaching strategies that enhance the development of 4th grade students' experimental design skills at a public primary school in Argentina. Students' performance in the design of relevant experiments was evaluated before and after an eight-week intervention compared to a control group, as well as the persistence of this learning after eight months. The study involved a quasi-experimental longitudinal study with pre-test/post-test/delayed post-test measures, complemented with semi-structured interviews with randomly selected students. Our findings showed improvement in the experimental design skills as well as its sustainability among students working with the inquiry-based sequence. After the intervention, students were able to establish valid comparisons, propose pertinent designs and identify variables that should remain constant. Contrarily, students in the control group showed no improvement and continued to solve the posed problems based on prior beliefs. In summary, this paper shows evidence that implementing inquiry-based units involving problems set in cross-domain everyday situations that combine independent student work with teacher guidance significantly improves the development of scientific skills in real classroom contexts.
Advanced Supersonic Nozzle Concepts: Experimental Flow Visualization Results Paired With LES
NASA Astrophysics Data System (ADS)
Berry, Matthew; Magstadt, Andrew; Stack, Cory; Gaitonde, Datta; Glauser, Mark; Syracuse University Team; The Ohio State University Team
2015-11-01
Advanced supersonic nozzle concepts are currently under investigation, utilizing multiple bypass streams and airframe integration to bolster performance and efficiency. This work focuses on the parametric study of a supersonic, multi-stream jet with aft deck. The single plane of symmetry, rectangular nozzle, displays very complex and unique flow characteristics. Flow visualization techniques in the form of PIV and schlieren capture flow features at various deck lengths and Mach numbers. LES is compared to the experimental results to both validate the computational model and identify limitations of the simulation. By comparing experimental results to LES, this study will help create a foundation of knowledge for advanced nozzle designs in future aircraft. SBIR Phase II with Spectral Energies, LLC under direction of Barry Kiel.
Integrated active and passive control design methodology for the LaRC CSI evolutionary model
NASA Technical Reports Server (NTRS)
Voth, Christopher T.; Richards, Kenneth E., Jr.; Schmitz, Eric; Gehling, Russel N.; Morgenthaler, Daniel R.
1994-01-01
A general design methodology to integrate active control with passive damping was demonstrated on the NASA LaRC CSI Evolutionary Model (CEM), a ground testbed for future large, flexible spacecraft. Vibration suppression controllers designed for Line-of Sight (LOS) minimization were successfully implemented on the CEM. A frequency-shaped H2 methodology was developed, allowing the designer to specify the roll-off of the MIMO compensator. A closed loop bandwidth of 4 Hz, including the six rigid body modes and the first three dominant elastic modes of the CEM was achieved. Good agreement was demonstrated between experimental data and analytical predictions for the closed loop frequency response and random tests. Using the Modal Strain Energy (MSE) method, a passive damping treatment consisting of 60 viscoelastically damped struts was designed, fabricated and implemented on the CEM. Damping levels for the targeted modes were more than an order of magnitude larger than for the undamped structure. Using measured loss and stiffness data for the individual damped struts, analytical predictions of the damping levels were very close to the experimental values in the (1-10) Hz frequency range where the open loop model matched the experimental data. An integrated active/passive controller was successfully implemented on the CEM and was evaluated against an active-only controller. A two-fold increase in the effective control bandwidth and further reductions of 30 percent to 50 percent in the LOS RMS outputs were achieved compared to an active-only controller. Superior performance was also obtained compared to a High-Authority/Low-Authority (HAC/LAC) controller.
Coelho, Pedro G; Hollister, Scott J; Flanagan, Colleen L; Fernandes, Paulo R
2015-03-01
Bone scaffolds for tissue regeneration require an optimal trade-off between biological and mechanical criteria. Optimal designs may be obtained using topology optimization (homogenization approach) and prototypes produced using additive manufacturing techniques. However, the process from design to manufacture remains a research challenge and will be a requirement of FDA design controls to engineering scaffolds. This work investigates how the design to manufacture chain affects the reproducibility of complex optimized design characteristics in the manufactured product. The design and prototypes are analyzed taking into account the computational assumptions and the final mechanical properties determined through mechanical tests. The scaffold is an assembly of unit-cells, and thus scale size effects on the mechanical response considering finite periodicity are investigated and compared with the predictions from the homogenization method which assumes in the limit infinitely repeated unit cells. Results show that a limited number of unit-cells (3-5 repeated on a side) introduce some scale-effects but the discrepancies are below 10%. Higher discrepancies are found when comparing the experimental data to numerical simulations due to differences between the manufactured and designed scaffold feature shapes and sizes as well as micro-porosities introduced by the manufacturing process. However good regression correlations (R(2) > 0.85) were found between numerical and experimental values, with slopes close to 1 for 2 out of 3 designs. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Robichaud, Guillaume; Dixon, R. Brent; Potturi, Amarnatha S.; Cassidy, Dan; Edwards, Jack R.; Sohn, Alex; Dow, Thomas A.; Muddiman, David C.
2010-01-01
Through a multi-disciplinary approach, the air amplifier is being evolved as a highly engineered device to improve detection limits of biomolecules when using electrospray ionization. Several key aspects have driven the modifications to the device through experimentation and simulations. We have developed a computer simulation that accurately portrays actual conditions and the results from these simulations are corroborated by the experimental data. These computer simulations can be used to predict outcomes from future designs resulting in a design process that is efficient in terms of financial cost and time. We have fabricated a new device with annular gap control over a range of 50 to 70 μm using piezoelectric actuators. This has enabled us to obtain better aerodynamic performance when compared to the previous design (2× more vacuum) and also more reproducible results. This is allowing us to study a broader experimental space than the previous design which is critical in guiding future directions. This work also presents and explains the principles behind a fractional factorial design of experiments methodology for testing a large number of experimental parameters in an orderly and efficient manner to understand and optimize the critical parameters that lead to obtain improved detection limits while minimizing the number of experiments performed. Preliminary results showed that several folds of improvements could be obtained for certain condition of operations (up to 34 folds). PMID:21499524
Computational Study of Axisymmetric Off-Design Nozzle Flows
NASA Technical Reports Server (NTRS)
DalBello, Teryn; Georgiadis, Nicholas; Yoder, Dennis; Keith, Theo
2003-01-01
Computational Fluid Dynamics (CFD) analyses of axisymmetric circular-arc boattail nozzles operating off-design at transonic Mach numbers have been completed. These computations span the very difficult transonic flight regime with shock-induced separations and strong adverse pressure gradients. External afterbody and internal nozzle pressure distributions computed with the Wind code are compared with experimental data. A range of turbulence models were examined, including the Explicit Algebraic Stress model. Computations have been completed at freestream Mach numbers of 0.9 and 1.2, and nozzle pressure ratios (NPR) of 4 and 6. Calculations completed with variable time-stepping (steady-state) did not converge to a true steady-state solution. Calculations obtained using constant timestepping (timeaccurate) indicate less variations in flow properties compared with steady-state solutions. This failure to converge to a steady-state solution was the result of using variable time-stepping with large-scale separations present in the flow. Nevertheless, time-averaged boattail surface pressure coefficient and internal nozzle pressures show reasonable agreement with experimental data. The SST turbulence model demonstrates the best overall agreement with experimental data.
Added-purpose versus rote exercise in female nursing home residents.
Yoder, R M; Nelson, D L; Smith, D A
1989-09-01
Seven recent experimental and quasi-experimental studies have compared the exercise of subjects instructed to pursue some added goal (often termed purposeful activity) with the exercise of subjects instructed to exercise without the suggestion of an added goal (often termed nonpurposeful activity). This article suggests a new terminology for this type of independent variable and describes an experiment within this developing tradition. An occupational form designed, through materials and instructions, to elicit a rotary arm exercise with the added purpose of stirring cookie dough was compared with an occupational form designed to elicit the rotary arm exercise with no added purpose. The subjects were 30 elderly female nursing home residents randomly assigned to the occupational forms. Results indicated that the added-purpose, occupationally embedded exercise condition elicited significantly more exercise repetitions than did the rote exercise condition (one-tailed p = .012). Exercise duration and exercise stoppages were also recorded. This study provides additional support for the traditional occupational therapy idea of embedding exercise within occupation. Suggestions are made for future research involving the experimental analysis of therapeutic occupation.
ERIC Educational Resources Information Center
LeMaire, Peter; Waiveris, Charles
1995-01-01
Describes experiments designed to investigate the cooling rate of microwave-boiled water as compared to that of stove-boiled water. Concludes that within experimental limits, microwave-boiled water and stove-boiled water cool at the same rate. (JRH)
Comparative Evaluation of Quantitative Test Methods for Gases on a Hard Surface
2017-02-01
COMPARATIVE EVALUATION OF QUANTITATIVE TEST METHODS FOR GASES ON A HARD SURFACE ECBC-TR-1426 Vipin Rastogi...1 COMPARATIVE EVALUATION OF QUANTITATIVE TEST METHODS FOR GASES ON A HARD SURFACE 1. INTRODUCTION Members of the U.S. Environmental...Generator 4 2.4 Experimental Design Each quantitative method was performed three times on three consecutive days. For the CD runs, three
Counteracting moment device for reduction of earthquake-induced excursions of multi-level buildings.
Nagaya, K; Fukushima, T; Kosugi, Y
1999-05-01
A vibration-control mechanism for beams and columns was presented in our previous report in which the earthquake force was transformed into a vibration-control force by using a gear train mechanism. In our previous report, however, only the principle of transforming the earthquake force into the control force was presented; the discussion for real structures and the design method were not presented. The present article provides a theoretical analysis of the column which is used in multi-layered buildings. Experimental tests were carried out for a model of multi-layered buildings in the frequency range of a principal earthquake wave. Theoretical results are compared to the experimental data. The optimal design of the control mechanism, which is of importance in the column design, is presented. Numerical calculations are carried out for the optimal design. It is shown that vibrations of the column involving the mechanism are suppressed remarkably. The optimal design method and the analytical results are applicable to the design of the column.
Wang, Quanfu; Hou, Yanhua; Yan, Peisheng
2012-06-01
Statistical experimental designs were employed to optimize culture conditions for cold-adapted lysozyme production of a psychrophilic yeast Debaryomyces hansenii. In the first step of optimization using Plackett-Burman design (PBD), peptone, glucose, temperature, and NaCl were identified as significant variables that affected lysozyme production, the formula was further optimized using a four factor central composite design (CCD) to understand their interaction and to determine their optimal levels. A quadratic model was developed and validated. Compared to the initial level (18.8 U/mL), the maximum lysozyme production (65.8 U/mL) observed was approximately increased by 3.5-fold under the optimized conditions. Cold-adapted lysozymes production was first optimized using statistical experimental methods. A 3.5-fold enhancement of microbial lysozyme was gained after optimization. Such an improved production will facilitate the application of microbial lysozyme. Thus, D. hansenii lysozyme may be a good and new resource for the industrial production of cold-adapted lysozymes. © 2012 Institute of Food Technologists®
NASA Astrophysics Data System (ADS)
Lazonder, Ard W.; Wiskerke-Drost, Sjanou
2015-02-01
Several studies found that direct instruction and task structuring can effectively promote children's ability to design unconfounded experiments. The present study examined whether the impact of these interventions extends to other scientific reasoning skills by comparing the inquiry activities of 55 fifth-graders randomly assigned to one of three conditions. Children in the control condition investigated a four-variable inquiry task without additional support. Performance of this task in the direct instruction condition was preceded by a short training in experimental design, whereas children in the task structuring condition, who did not receive the introductory training, were given a version of the task that addressed the four variables one at a time. Analysis of children's experimentation behavior confirmed that direct instruction and task structuring are equally effective and superior to unguided inquiry. Both interventions also evoked more determinate predictions and valid inferences. These findings demonstrate that the effect of short-term interventions designed to promote unconfounded experimentation extends beyond the control of variables.
Nunes, Edward V; Ball, Samuel; Booth, Robert; Brigham, Gregory; Calsyn, Donald A; Carroll, Kathleen; Feaster, Daniel J; Hien, Denise; Hubbard, Robert L; Ling, Walter; Petry, Nancy M; Rotrosen, John; Selzer, Jeffrey; Stitzer, Maxine; Tross, Susan; Wakim, Paul; Winhusen, Theresa; Woody, George
2010-06-01
Multisite effectiveness trials such as those carried out in the National Drug Abuse Treatment Clinical Trials Network (CTN) are a critical step in the development and dissemination of evidence-based treatments because they address how such treatments perform in real-world clinical settings. As Brigham et al. summarized in a recent article (G. S. Brigham, D. J. Feaster, P. G. Wakim, & C. L. Dempsey C. L., 2009), several possible experimental designs may be chosen for such effectiveness trials. These include (a) a new treatment intervention (Tx) is compared to an existing mode of community based treatment as usual (TAU): Tx versus TAU; (b) a new intervention is added to TAU and compared to TAU alone: Tx + TAU versus TAU; or (c) a new intervention is added to TAU and compared to a control condition added to TAU: Tx + TAU versus control + TAU. Each of these designs addresses a different question and has different potential strengths and weaknesses. As of December 2009, the primary outcome paper had been published for 16 of the multisite randomized clinical trials conducted in the CTN, testing various treatments for drug abuse, HIV risk behavior, or related problems. This paper systematically examines, for each of the completed trials, the experimental design type chosen and its original rationale, the main findings of the trial, and the strengths and weaknesses of the design in hindsight. Based on this review, recommendations are generated to inform the design of future effectiveness trials on treatments for substance abuse, HIV risk, and other behavioral health problems.
Conti, Michele; Van Loo, Denis; Auricchio, Ferdinando; De Beule, Matthieu; De Santis, Gianluca; Verhegghe, Benedict; Pirrelli, Stefano; Odero, Attilio
2011-06-01
To quantitatively evaluate the impact of carotid stent cell design on vessel scaffolding by using patient-specific finite element analysis of carotid artery stenting (CAS). The study was organized in 2 parts: (1) validation of a patient-specific finite element analysis of CAS and (2) evaluation of vessel scaffolding. Micro-computed tomography (CT) images of an open-cell stent deployed in a patient-specific silicone mock artery were compared with the corresponding finite element analysis results. This simulation was repeated for the closed-cell counterpart. In the second part, the stent strut distribution, as reflected by the inter-strut angles, was evaluated for both cell types in different vessel cross sections as a measure of scaffolding. The results of the patient-specific finite element analysis of CAS matched well with experimental stent deployment both qualitatively and quantitatively, demonstrating the reliability of the numerical approach. The measured inter-strut angles suggested that the closed-cell design provided superior vessel scaffolding compared to the open-cell counterpart. However, the full strut interconnection of the closed-cell design reduced the stent's ability to accommodate to the irregular eccentric profile of the vessel cross section, leading to a gap between the stent surface and the vessel wall. Even though this study was limited to a single stent design and one vascular anatomy, the study confirmed the capability of dedicated computer simulations to predict differences in scaffolding by open- and closed-cell carotid artery stents. These simulations have the potential to be used in the design of novel carotid stents or for procedure planning.
NASA Astrophysics Data System (ADS)
Fuchs, Sven; Ziesche, Michael; Nillert, Peter
2017-06-01
This paper comprises a review of the 13 studies that have been proposed for the derivation of porosity, effective porosity and/or specific yield from grain size distributions (Lejbenson 1947; Istomina 1957; Beyer 1964; Hennig 1966; Golf 1966; Marotz 1968; Beyer und Schweiger 1969; Seiler 1973; Bureau of Reclamation 1984; Helmbold 1988; Beims und Luckner 1999; Balke et al. 2000; Helmbold 2002). Experimental design, limitations and application boundaries are discussed and methods are compared against each other. The quality of the predictive methods strongly depends on the experimental design and the sample type.
Numerical design of streamlined tunnel walls for a two-dimensional transonic test
NASA Technical Reports Server (NTRS)
Newman, P. A.; Anderson, E. C.
1978-01-01
An analytical procedure is discussed for designing wall shapes for streamlined, nonporous, two-dimensional, transonic wind tunnels. It is based upon currently available 2-D inviscid transonic and boundary layer analysis computer programs. Predicted wall shapes are compared with experimental data obtained from the NASA Langley 6 by 19 inch Transonic Tunnel where the slotted walls were replaced by flexible nonporous walls. Comparisons are presented for the empty tunnel operating at a Mach number of 0.9 and for a supercritical test of an NACA 0012 airfoil at zero lift. Satisfactory agreement is obtained between the analytically and experimentally determined wall shapes.
D-Optimal Experimental Design for Contaminant Source Identification
NASA Astrophysics Data System (ADS)
Sai Baba, A. K.; Alexanderian, A.
2016-12-01
Contaminant source identification seeks to estimate the release history of a conservative solute given point concentration measurements at some time after the release. This can be mathematically expressed as an inverse problem, with a linear observation operator or a parameter-to-observation map, which we tackle using a Bayesian approach. Acquisition of experimental data can be laborious and expensive. The goal is to control the experimental parameters - in our case, the sparsity of the sensors, to maximize the information gain subject to some physical or budget constraints. This is known as optimal experimental design (OED). D-optimal experimental design seeks to maximize the expected information gain, and has long been considered the gold standard in the statistics community. Our goal is to develop scalable methods for D-optimal experimental designs involving large-scale PDE constrained problems with high-dimensional parameter fields. A major challenge for the OED, is that a nonlinear optimization algorithm for the D-optimality criterion requires repeated evaluation of objective function and gradient involving the determinant of large and dense matrices - this cost can be prohibitively expensive for applications of interest. We propose novel randomized matrix techniques that bring down the computational costs of the objective function and gradient evaluations by several orders of magnitude compared to the naive approach. The effect of randomized estimators on the accuracy and the convergence of the optimization solver will be discussed. The features and benefits of our new approach will be demonstrated on a challenging model problem from contaminant source identification involving the inference of the initial condition from spatio-temporal observations in a time-dependent advection-diffusion problem.
Design and validation of the eyesafe ladar testbed (ELT) using the LadarSIM system simulator
NASA Astrophysics Data System (ADS)
Neilsen, Kevin D.; Budge, Scott E.; Pack, Robert T.; Fullmer, R. Rees; Cook, T. Dean
2009-05-01
The development of an experimental full-waveform LADAR system has been enhanced with the assistance of the LadarSIM system simulation software. The Eyesafe LADAR Test-bed (ELT) was designed as a raster scanning, single-beam, energy-detection LADAR with the capability of digitizing and recording the return pulse waveform at up to 2 GHz for 3D off-line image formation research in the laboratory. To assist in the design phase, the full-waveform LADAR simulation in LadarSIM was used to simulate the expected return waveforms for various system design parameters, target characteristics, and target ranges. Once the design was finalized and the ELT constructed, the measured specifications of the system and experimental data captured from the operational sensor were used to validate the behavior of the system as predicted during the design phase. This paper presents the methodology used, and lessons learned from this "design, build, validate" process. Simulated results from the design phase are presented, and these are compared to simulated results using measured system parameters and operational sensor data. The advantages of this simulation-based process are also presented.
ERIC Educational Resources Information Center
Clark, Sheldon B.; Boser, Judith A.
The suggestions offered in this paper are based on the experiences of two scientific researchers of how evaluations undertaken in a competitive arena, in which true experimental designs are not viable, can be designed in such a way that meaningful comparative data can be examined. Case studies of the Science and Engineering Research Semester and…
2010-06-01
Markus, 1994). Media richness theory rests on the assumption that organizations process information to reduce uncertainty and equivocality ( Daft ... Organization Design ), 554-571. Daft , R. L., & Macintosh, N. B. (1981). A tentative exploration into the amount and equivocality of information... design and customization. For instance, recent research demonstrates further how the performance of both Hierarchy and Edge organizations is
Promoting an Inclusive Image of Scientists among Students: Towards Research Evidence-Based Practice
ERIC Educational Resources Information Center
Cakmakci, Gultekin; Tosun, Ozge; Turgut, Sebnem; Orenler, Sefika; Sengul, Kubra; Top, Gokce
2011-01-01
This study aims at investigating the effects of a teaching intervention, the design of which is informed by evidence from educational theories and research data, on students' images of scientists. A quasi-experimental design with a non-equivalent pre-test-post-test control group (CG) was used to compare the outcomes of the intervention. The…
Comparison of Example-Based Learning and Problem-Based Learning in Engineering Domain
ERIC Educational Resources Information Center
Sern, Lai Chee; Salleh, Kahirol Mohd; Sulaiman, Nor lisa; Mohamad, Mimi Mohaffyza; Yunos, Jailani Md
2015-01-01
The research was conducted to compare the impacts of problem-based learning (PBL) and example-based learning (EBL) on the learning performance in an engineering domain. The research was implemented by means of experimental design. Specifically, a two-group experiment with a pre- and post-test design was used in this research. A total of 37…
Design and Analysis of Bionic Cutting Blades Using Finite Element Method.
Li, Mo; Yang, Yuwang; Guo, Li; Chen, Donghui; Sun, Hongliang; Tong, Jin
2015-01-01
Praying mantis is one of the most efficient predators in insect world, which has a pair of powerful tools, two sharp and strong forelegs. Its femur and tibia are both armed with a double row of strong spines along their posterior edges which can firmly grasp the prey, when the femur and tibia fold on each other in capturing. These spines are so sharp that they can easily and quickly cut into the prey. The geometrical characteristic of the praying mantis's foreleg, especially its tibia, has important reference value for the design of agricultural soil-cutting tools. Learning from the profile and arrangement of these spines, cutting blades with tooth profile were designed in this work. Two different sizes of tooth structure and arrangement were utilized in the design on the cutting edge. A conventional smooth-edge blade was used to compare with the bionic serrate-edge blades. To compare the working efficiency of conventional blade and bionic blades, 3D finite element simulation analysis and experimental measurement were operated in present work. Both the simulation and experimental results indicated that the bionic serrate-edge blades showed better performance in cutting efficiency.
Design and Analysis of Bionic Cutting Blades Using Finite Element Method
Li, Mo; Yang, Yuwang; Guo, Li; Chen, Donghui; Sun, Hongliang; Tong, Jin
2015-01-01
Praying mantis is one of the most efficient predators in insect world, which has a pair of powerful tools, two sharp and strong forelegs. Its femur and tibia are both armed with a double row of strong spines along their posterior edges which can firmly grasp the prey, when the femur and tibia fold on each other in capturing. These spines are so sharp that they can easily and quickly cut into the prey. The geometrical characteristic of the praying mantis's foreleg, especially its tibia, has important reference value for the design of agricultural soil-cutting tools. Learning from the profile and arrangement of these spines, cutting blades with tooth profile were designed in this work. Two different sizes of tooth structure and arrangement were utilized in the design on the cutting edge. A conventional smooth-edge blade was used to compare with the bionic serrate-edge blades. To compare the working efficiency of conventional blade and bionic blades, 3D finite element simulation analysis and experimental measurement were operated in present work. Both the simulation and experimental results indicated that the bionic serrate-edge blades showed better performance in cutting efficiency. PMID:27019583
Can Building Design Impact Physical Activity? A Natural Experiment.
Eyler, Amy A; Hipp, Aaron; Valko, Cheryl Ann; Ramadas, Ramya; Zwald, Marissa
2018-05-01
Workplace design can impact workday physical activity (PA) and sedentary time. The purpose of this study was to evaluate PA behavior among university employees before and after moving into a new building. A pre-post, experimental versus control group study design was used. PA data were collected using surveys and accelerometers from university faculty and staff. Accelerometry was used to compare those moving into the new building (MOVERS) and those remaining in existing buildings (NONMOVERS) and from a control group (CONTROLS). Survey results showed increased self-reported PA for MOVERS and NONMOVERS. All 3 groups significantly increased in objectively collected daily energy expenditure and steps per day. The greatest steps per day increase was in CONTROLS (29.8%) compared with MOVERS (27.5%) and NONMOVERS (15.9%), but there were no significant differences between groups at pretest or posttest. Self-reported and objectively measured PA increased from pretest to posttest in all groups; thus, the increase cannot be attributed to the new building. Confounding factors may include contamination bias due to proximity of control site to experimental site and introduction of a university PA tracking contest during postdata collection. Methodology and results can inform future studies on best design practices for increasing PA.
What is the best?: simple versus visitor restricted rest period.
Silvius-Byron, Stephanie A; Florimonte, Christine; Panganiban, Elizabeth G; Ulmer, Janice Fitzgerald
2014-05-01
The aim of this study was to compare a highly structured planned rest protocol that includes visitor and healthcare personnel restrictions with a simple planned rest period that encourages patients to rest during a designated time without restriction of visitors and healthcare personnel. Many hospitals acute care have begun to restrict visitors and nonessential health team interventions during specific times despite the lack of experimentally designed studies. Using a convenience sample of 52 intermediate care unit patients, a randomized experimental design study compared a highly structured planned rest protocol with restriction of visitors/healthcare personnel to a simple planned rest period without restrictions. The primary outcome variable was the patient's perceived quality of rest after a 2-hour rest period. Intermediate care patients' perception of rest and sleep during a designated rest period was similar whether elaborate rest strategies were used, including visitor and healthcare personnel restrictions, or if it was only suggested they rest and the door to their room closed. The restriction of visitors and healthcare personnel during a 2-hour rest period did not improve the patient's perception of rest or how long it took them to go to sleep.
ERIC Educational Resources Information Center
Alajmi, Maadi Mahdi; Al-Hadiah, Hanan Abdullah
2017-01-01
This study aims to examine the effectiveness of using the iPad in learning to acquire the mental and performance skills in teaching the social studies. Using experimental design method, the study compared two groups: (a) experimental, taught using the iPad, and (b) control group, taught using the traditional learning without iPad. A total of 48…
Army Field-Oriented S&T Experimentation Venues: A Comparative Analysis
2011-09-01
Microclimate Cooling Station (MCCS)). The Fort Benning AEWE provides the venue and the data collection and analysis. The costs to the S&T...forest, fields, etc.) and is designated as an Army experimental station with access to ground and an aerial fleet. Technology developers have optional...YTC), (2) tropical (the Tropic Regions Test Center, Panama Canal Zone), and (3) cold weather (CRTC, Bolio Lake Test Complex, AK. Special
Experimental validation of a new heterogeneous mechanical test design
NASA Astrophysics Data System (ADS)
Aquino, J.; Campos, A. Andrade; Souto, N.; Thuillier, S.
2018-05-01
Standard material parameters identification strategies generally use an extensive number of classical tests for collecting the required experimental data. However, a great effort has been made recently by the scientific and industrial communities to support this experimental database on heterogeneous tests. These tests can provide richer information on the material behavior allowing the identification of a more complete set of material parameters. This is a result of the recent development of full-field measurements techniques, like digital image correlation (DIC), that can capture the heterogeneous deformation fields on the specimen surface during the test. Recently, new specimen geometries were designed to enhance the richness of the strain field and capture supplementary strain states. The butterfly specimen is an example of these new geometries, designed through a numerical optimization procedure where an indicator capable of evaluating the heterogeneity and the richness of strain information. However, no experimental validation was yet performed. The aim of this work is to experimentally validate the heterogeneous butterfly mechanical test in the parameter identification framework. For this aim, DIC technique and a Finite Element Model Up-date inverse strategy are used together for the parameter identification of a DC04 steel, as well as the calculation of the indicator. The experimental tests are carried out in a universal testing machine with the ARAMIS measuring system to provide the strain states on the specimen surface. The identification strategy is accomplished with the data obtained from the experimental tests and the results are compared to a reference numerical solution.
Abrahamyan, Lusine; Li, Chuan Silvia; Beyene, Joseph; Willan, Andrew R; Feldman, Brian M
2011-03-01
The study evaluated the power of the randomized placebo-phase design (RPPD)-a new design of randomized clinical trials (RCTs), compared with the traditional parallel groups design, assuming various response time distributions. In the RPPD, at some point, all subjects receive the experimental therapy, and the exposure to placebo is for only a short fixed period of time. For the study, an object-oriented simulation program was written in R. The power of the simulated trials was evaluated using six scenarios, where the treatment response times followed the exponential, Weibull, or lognormal distributions. The median response time was assumed to be 355 days for the placebo and 42 days for the experimental drug. Based on the simulation results, the sample size requirements to achieve the same level of power were different under different response time to treatment distributions. The scenario where the response times followed the exponential distribution had the highest sample size requirement. In most scenarios, the parallel groups RCT had higher power compared with the RPPD. The sample size requirement varies depending on the underlying hazard distribution. The RPPD requires more subjects to achieve a similar power to the parallel groups design. Copyright © 2011 Elsevier Inc. All rights reserved.
Effect of glenoid implant design on glenohumeral stability: an experimental study.
Sins, Lauranne; Tétreault, Patrice; Petit, Yvan; Nuño, Natalia; Billuart, Fabien; Hagemeister, Nicola
2012-10-01
Though several glenoid implants were developed over the past years, a high rate of glenoid loosening remains. This complication is linked to the glenohumeral stability, defined as humeral head translation. In an intact shoulder, this concept is ensured by all active and passive elements, particularly the labrum. Two features of a glenoid implant can be adjusted to improve the stability, or, in other words, to decrease the translations: the first is the mismatch, defined as the difference of curvature between the prosthetic head and glenoid; the second is the shape of the glenoid component. Therefore, the objective of this study was to compare the performance of 2 glenoid components (Ceraver, Roissy, France): (1) a standard design and (2) a design named "labrum design" with a superior part simulating the anatomic labrum. An experimental device was developed to evaluate forces and kinematics. The device simulated active, dynamic and continuous abduction of an entire arm. It reproduced the Scapulo-Humeral Rhythm. The labrum design was installed first. To evaluate the effect of mismatch on the glenohumeral stability, 3 humeral heads were tested, corresponding to the ones recommended by the company. The experiment was repeated for the standard design. The results obtained show a general decrease of the prosthetic head translation with the labrum design compared to the standard design. No noticeable effect of mismatch was found. A proof of concept of the interest of the artificial labrum was provided since it improved the glenohumeral stability. Copyright © 2012 Elsevier Ltd. All rights reserved.
The effect of ethanol vapour exposure on atrial and ventricular walls of chick embryos.
Kamran, Kiran; Khan, Muhammad Yunus; Minhas, Liaqat Ali
2016-10-01
To study the effects of ethanol vapour exposure on atrial and ventricular walls of heart in chick embryo. The study design was experimental, conducted at Islamabad Centre of College of Physicians and Surgeons, Pakistan. One hundred and eighty chicken eggs were divided into two groups, experimental and control, of 90 eggs each. Each group was subdivided into three subgroups of 30 eggs each based on the day of sacrifice. Experimental group was exposed to ethanol vapours and then compared with age matched controls. The thickness of atrial and ventricular walls along with lengths of valvular cusps increased in hearts of day 7 and day 10 chick embryos in experimental group. There was thinning of walls and decreased length of valvular cusps in hearts of experimental chicks on hatching as compared to age matched controls. Ethanol vapour exposure during development causes cardiac and septal wall thickening during initial days of development followed by cardiac and septal wall thinning which is a classical picture of alcohol induced cardiomyopathies.
10 CFR Appendix K to Part 50 - ECCS Evaluation Models
Code of Federal Regulations, 2012 CFR
2012-01-01
... stated circumstances shall be justified by comparative analyses or by experimental data. 4. Critical Heat..., ASME, New York, 1969. (3) Hench-Levy. J. M. Healzer, J. E. Hench, E. Janssen, S. Levy, “Design Basis...
10 CFR Appendix K to Part 50 - ECCS Evaluation Models
Code of Federal Regulations, 2013 CFR
2013-01-01
... stated circumstances shall be justified by comparative analyses or by experimental data. 4. Critical Heat..., ASME, New York, 1969. (3) Hench-Levy. J. M. Healzer, J. E. Hench, E. Janssen, S. Levy, “Design Basis...
10 CFR Appendix K to Part 50 - ECCS Evaluation Models
Code of Federal Regulations, 2014 CFR
2014-01-01
... stated circumstances shall be justified by comparative analyses or by experimental data. 4. Critical Heat..., ASME, New York, 1969. (3) Hench-Levy. J. M. Healzer, J. E. Hench, E. Janssen, S. Levy, “Design Basis...
Feldman, Leonard H; Fertig, Amanda
2013-01-01
While relative care may offer significant benefits to kin children as compared to non-relative foster care, informal kinship caregivers often experience various hardships and needs without the resources of the child welfare system to aid them. They may benefit from services provided by an expanded kinship navigator program. This study, using an experimental design, adds to knowledge about the characteristics and needs of kinship caregivers and the impact of enhanced navigator services. The relative effect of this more intensive intervention was mixed. Caregivers had many of their expressed needs met. Yet, the enhanced services group did not demonstrate: an increase in perceived social support; reduction in caregiver stress; or improvement in child behavior compared to the families receiving brief, traditional navigator services. Little difference was found in post intervention involvement in the child welfare system. Further enhancements to the model are suggested.
HOLLOTRON switch for megawatt lightweight space inverters
NASA Technical Reports Server (NTRS)
Poeschel, R. L.; Goebel, D. M.; Schumacher, R. W.
1991-01-01
The feasibility of satisfying the switching requirements for a megawatt ultralight inverter system using HOLLOTRON switch technology was determined. The existing experimental switch hardware was modified to investigate a coaxial HOLLOTRON switch configuration and the results were compared with those obtained for a modified linear HOLLOTRON configuration. It was concluded that scaling the HOLLOTRON switch to the current and voltage specifications required for a megawatt converter system is indeed feasible using a modified linear configuration. The experimental HOLLOTRON switch operated at parameters comparable to the scaled coaxial HOLLOTRON. However, the linear HOLLOTRON data verified the capability for meeting all the design objectives simultaneously including current density (greater than 2 A/sq cm), voltage (5 kV), switching frequency (20 kHz), switching time (300 ns), and forward voltage drop (less than or equal to 20 V). Scaling relations were determined and a preliminary design was completed for an engineering model linear HOLLOTRON switch to meet the megawatt converter system specifications.
Narrative Enhancement and Cognitive Therapy (NECT) Effectiveness: A Quasi-Experimental Study
Roe, David; Hasson-Ohayon, Ilanit; Mashiach-Eizenberg, Michal; Derhy, Oren; Lysaker, Paul H.; Yanos, Philip T.
2014-01-01
Objective Accumulated evidence suggests that approximately one third of people with a serious mental illness (SMI) experience elevated self-stigma. Narrative enhancement and cognitive therapy (NECT) is a structured group-based intervention aimed to reduce self-stigma. The current study aims to examine the effectiveness of NECT. A quasi-experimental design. Design Baseline and follow-up data were collected and outcomes were compared between 63 persons with SMI who participated in NECT and 56 persons who received treatment as usual. Results The NECT treatment group showed significant (p < .05) reductions in self-stigma and increases in self-esteem, quality of life, and Hope-Agency scores between pre- and posttreatment assessments, compared with the control group. Conclusions The current results provide preliminary support for the use of NECT as an effective treatment to reduce self-stigma and its implications for treatment and practice are discussed. PMID:24114797
Moving belt radiator development status
NASA Technical Reports Server (NTRS)
White, K. Alan
1988-01-01
Development of the Moving Belt Radiator (MBR) as an advanced space radiator concept is discussed. The ralative merits of Solid Belt (SBR), Liquid Belt (LBR), and Hybrid Belt (HBR) Radiators are described. Analytical and experimental efforts related to the dynamics of a rotating belt in microgravity are reviewed. The development of methods for transferring heat to the moving belt is discussed, and the results from several experimental investigations are summarized. Limited efforts related to the belt deployment and stowage, and to fabrication of a hybrid belt, are also discussed. Life limiting factors such as seal wear and micrometeroid resistance are identified. The results from various MBR point design studies for several power levels are compared with advanced Heat Pipe Radiator technology. MBR designs are shown to compare favorable at both 300 and 1000 K temperature levels. However, additional effort will be required to resolve critical technology issues and to demonstrate the advantage of MBR systems.
Wet scrubbing of biomass producer gas tars using vegetable oil
NASA Astrophysics Data System (ADS)
Bhoi, Prakashbhai Ramabhai
The overall aims of this research study were to generate novel design data and to develop an equilibrium stage-based thermodynamic model of a vegetable oil based wet scrubbing system for the removal of model tar compounds (benzene, toluene and ethylbenzene) found in biomass producer gas. The specific objectives were to design, fabricate and evaluate a vegetable oil based wet scrubbing system and to optimize the design and operating variables; i.e., packed bed height, vegetable oil type, solvent temperature, and solvent flow rate. The experimental wet packed bed scrubbing system includes a liquid distributor specifically designed to distribute a high viscous vegetable oil uniformly and a mixing section, which was designed to generate a desired concentration of tar compounds in a simulated air stream. A method and calibration protocol of gas chromatography/mass spectroscopy was developed to quantify tar compounds. Experimental data were analyzed statistically using analysis of variance (ANOVA) procedure. Statistical analysis showed that both soybean and canola oils are potential solvents, providing comparable removal efficiency of tar compounds. The experimental height equivalent to a theoretical plate (HETP) was determined as 0.11 m for vegetable oil based scrubbing system. Packed bed height and solvent temperature had highly significant effect (p0.05) effect on the removal of model tar compounds. The packing specific constants, Ch and CP,0, for the Billet and Schultes pressure drop correlation were determined as 2.52 and 2.93, respectively. The equilibrium stage based thermodynamic model predicted the removal efficiency of model tar compounds in the range of 1-6%, 1-4% and 1-2% of experimental data for benzene, toluene and ethylbenzene, respectively, for the solvent temperature of 30° C. The NRTL-PR property model and UNIFAC for estimating binary interaction parameters are recommended for modeling absorption of tar compounds in vegetable oils. Bench scale experimental data from the wet scrubbing system would be useful in the design and operation of a pilot scale vegetable oil based system. The process model, validated using experimental data, would be a key design tool for the design and optimization of a pilot scale vegetable oil based system.
A Study of Reliability of Marking and Absolute Grading in Secondary Schools
ERIC Educational Resources Information Center
Abdul Gafoor, K.; Jisha, P.
2014-01-01
Using a non-experimental comparative group design in a sample consisting of 100 English teachers randomly selected from 30 secondary schools of a district of Kerala and assigning fifty teachers to groups for marking and grading, this study compares inter and intra-individual reliability in marking and absolute grading. Studying (1) the in marking…
Third Graders Explore Sound Concepts through Online Research Compared to Making Musical Instruments
ERIC Educational Resources Information Center
Borsay, Kyrie D.; Foss, Page
2016-01-01
This study is an exploration of several lessons on sound taught to third grade students using one of the Next Generation Science Standards (3-5-ETS1) and arts integration. A counterbalanced, pretest- posttest- distal posttest design experiment was conducted to compare student knowledge and attitudes between the control and experimental conditions.…
ERIC Educational Resources Information Center
Jenkins, Craig
2015-01-01
This paper is a comparative quantitative evaluation of an approach to teaching poetry in the subject domain of English that employs a "guided discovery" pedagogy using computer-based microworlds. It uses a quasi-experimental design in order to measure performance gains in computational thinking and poetic thinking following a…
Comparative Analysis of English Language Student's School Paths at a Mexico University
ERIC Educational Resources Information Center
Robelo, Octaviano García; Marquez, Jorge Hernández; Pérez, Ileana Casasola
2017-01-01
Seven factors related to academic paths of students of the Bachelor of English Language of a public university in Mexico are investigated. With a non-experimental descriptive design, a Likert scale was applied to evaluate the college students' perception of these factors. A comparative analysis between three types of school paths was performed. It…
ERIC Educational Resources Information Center
Hmelo-Silver, Cindy E.; Nagarajan, Anandi; Day, Roger S.
2002-01-01
Compares a group of expert cancer researchers with four groups of fourth year medical students (the "novice" groups) engaged in the task of designing a clinical trial to test a new cancer drug using a computer-based modeling tool, the Oncology Thinking Cap. (Contains 24 references.) (Author/YDS)
ERIC Educational Resources Information Center
Fan, Xitao; Wang, Lin
The Monte Carlo study compared the performance of predictive discriminant analysis (PDA) and that of logistic regression (LR) for the two-group classification problem. Prior probabilities were used for classification, but the cost of misclassification was assumed to be equal. The study used a fully crossed three-factor experimental design (with…
A Comparative View of the Roles of Women. Experimental Unit, Revised Edition.
ERIC Educational Resources Information Center
Miller, Barbara; Johnson, Jacquelyn
This unit explores the roles of women today and the possible effects of social, political, and economic equality for women on students' personal lives, the nation, and the world. Thirteen activities are designed to help secondary students develop an understanding of the status of women in U.S. society as compared with other cultures. These…
Service without a Smile: Comparing the Consequences of Neutral and Positive Display Rules
ERIC Educational Resources Information Center
Trougakos, John P.; Jackson, Christine L.; Beal, Daniel J.
2011-01-01
We used an experimental design to examine the intrapersonal and interpersonal processes through which neutral display rules, compared to positive display rules, influence objective task performance of poll workers and ratings provided by survey respondents of the poll workers. Student participants (N = 140) were trained to adhere to 1 of the 2…
Matha, Denis; Sandner, Frank; Molins, Climent; Campos, Alexis; Cheng, Po Wen
2015-01-01
The current key challenge in the floating offshore wind turbine industry and research is on designing economic floating systems that can compete with fixed-bottom offshore turbines in terms of levelized cost of energy. The preliminary platform design, as well as early experimental design assessments, are critical elements in the overall design process. In this contribution, a brief review of current floating offshore wind turbine platform pre-design and scaled testing methodologies is provided, with a focus on their ability to accommodate the coupled dynamic behaviour of floating offshore wind systems. The exemplary design and testing methodology for a monolithic concrete spar platform as performed within the European KIC AFOSP project is presented. Results from the experimental tests compared to numerical simulations are presented and analysed and show very good agreement for relevant basic dynamic platform properties. Extreme and fatigue loads and cost analysis of the AFOSP system confirm the viability of the presented design process. In summary, the exemplary application of the reduced design and testing methodology for AFOSP confirms that it represents a viable procedure during pre-design of floating offshore wind turbine platforms. PMID:25583870
Experimental results of active control on a large structure to suppress vibration
NASA Technical Reports Server (NTRS)
Dunn, H. J.
1991-01-01
Three design methods, Linear Quadratic Gaussian with Loop Transfer Recovery (LQG/LTR), H-infinity, and mu-synthesis, are used to obtain compensators for suppressing the vibrations of a 10-bay vertical truss structure, a component typical of what may be used to build a large space structure. For the design process the plant dynamic characteristics of the structure were determined experimentally using an identification method. The resulting compensators were implemented on a digital computer and tested for their ability to suppress the first bending mode response of the 10-bay vertical truss. Time histories of the measured motion are presented, and modal damping obtained during the experiments are compared with analytical predictions. The advantages and disadvantages of using the various design methods are discussed.
Quantifying anti-gravity torques in the design of a powered exoskeleton.
Ragonesi, Daniel; Agrawal, Sunil; Sample, Whitney; Rahman, Tariq
2011-01-01
Designing an upper extremity exoskeleton for people with arm weakness requires knowledge of the passive and active residual force capabilities of users. This paper experimentally measures the passive gravitational torques of 3 groups of subjects: able-bodied adults, able bodied children, and children with neurological disabilities. The experiment involves moving the arm to various positions in the sagittal plane and measuring the gravitational force at the wrist. This force is then converted to static gravitational torques at the elbow and shoulder. Data are compared between look-up table data based on anthropometry and empirical data. Results show that the look-up torques deviate from experimentally measured torques as the arm reaches up and down. This experiment informs designers of Upper Limb orthoses on the contribution of passive human joint torques.
Kośmider, Alicja; Białas, Wojciech; Kubiak, Piotr; Drożdżyńska, Agnieszka; Czaczyk, Katarzyna
2012-02-01
A two-step statistical experimental design was employed to optimize the medium for vitamin B(12) production from crude glycerol by Propionibacterium freudenreichii ssp. shermanii. In the first step, using Plackett-Burman design, five of 13 tested medium components (calcium pantothenate, NaH(2)PO(4)·2H(2)O, casein hydrolysate, glycerol and FeSO(4)·7H(2)O) were identified as factors having significant influence on vitamin production. In the second step, a central composite design was used to optimize levels of medium components selected in the first step. Valid statistical models describing the influence of significant factors on vitamin B(12) production were established for each optimization phase. The optimized medium provided a 93% increase in final vitamin concentration compared to the original medium. Copyright © 2011 Elsevier Ltd. All rights reserved.
Prediction of Cutting Force in Turning Process-an Experimental Approach
NASA Astrophysics Data System (ADS)
Thangarasu, S. K.; Shankar, S.; Thomas, A. Tony; Sridhar, G.
2018-02-01
This Paper deals with a prediction of Cutting forces in a turning process. The turning process with advanced cutting tool has a several advantages over grinding such as short cycle time, process flexibility, compatible surface roughness, high material removal rate and less environment problems without the use of cutting fluid. In this a full bridge dynamometer has been used to measure the cutting forces over mild steel work piece and cemented carbide insert tool for different combination of cutting speed, feed rate and depth of cut. The experiments are planned based on taguchi design and measured cutting forces were compared with the predicted forces in order to validate the feasibility of the proposed design. The percentage contribution of each process parameter had been analyzed using Analysis of Variance (ANOVA). Both the experimental results taken from the lathe tool dynamometer and the designed full bridge dynamometer were analyzed using Taguchi design of experiment and Analysis of Variance.
X-57 Power and Command System Design
NASA Technical Reports Server (NTRS)
Clarke, Sean; Redifer, Matthew; Papathakis, Kurt; Samuel, Aamod; Foster, Trevor
2017-01-01
This paper describes the power and command system architecture of the X-57 Maxwell flight demonstrator aircraft. The X-57 is an experimental aircraft designed to demonstrate radically improved aircraft efficiency with a 3.5 times aero-propulsive efficiency gain at a "high-speed cruise" flight condition for comparable general aviation aircraft. These gains are enabled by integrating the design of a new, optimized wing and a new electric propulsion system. As a result, the X-57 vehicle takes advantage of the new capabilities afforded by electric motors as primary propulsors. Integrating new technologies into critical systems in experimental aircraft poses unique challenges that require careful design considerations across the entire vehicle system, such as qualification of new propulsors (motors, in the case of the X-57 aircraft), compatibility of existing systems with a new electric power distribution bus, and instrumentation and monitoring of newly qualified propulsion system devices.
Identification and robust control of an experimental servo motor.
Adam, E J; Guestrin, E D
2002-04-01
In this work, the design of a robust controller for an experimental laboratory-scale position control system based on a dc motor drive as well as the corresponding identification and robust stability analysis are presented. In order to carry out the robust design procedure, first, a classic closed-loop identification technique is applied and then, the parametrization by internal model control is used. The model uncertainty is evaluated under both parametric and global representation. For the latter case, an interesting discussion about the conservativeness of this description is presented by means of a comparison between the uncertainty disk and the critical perturbation radius approaches. Finally, conclusions about the performance of the experimental system with the robust controller are discussed using comparative graphics of the controlled variable and the Nyquist stability margin as a robustness measurement.
Model Test of the Aerospace Laser Propulsion Engine
NASA Astrophysics Data System (ADS)
Ageichik, Alexander A.; Egorov, Maxim S.; Ostapenko, Svetlana V.; Rezunkov, Yuri A.; Safronov, Alexander L.; Stepanov, Vladimir V.
2005-04-01
One of the main results of the experimental and theoretical investigations made under the ISTC Project ♯ 1801 is the original design of Aerospace Laser Propulsion Engine (ASLPE) developed. The designed characteristics of the ASLPE flight model are experimentally approved, including the test experiments with a solid propellant. The obtained momentum coupling coefficient is rather high and comparable one with respect to the coefficient obtained by other researchers. Moreover, it is experimentally demonstrated that the thrust characteristics of the ASLPE flight model does not depend on angular aberrations of the beam coming onto the beam concentrator of the model with the incident angle of 0.01 radian. The experiments also demonstrated that successful launching of the vehicle with the ASLPE under the laser characteristics is possible also if the vehicle mass will be decreased and the thermal blooming effect will be eliminated.
Hovering Dual-Spin Vehicle Groundwork for Bias Momentum Sizing Validation Experiment
NASA Technical Reports Server (NTRS)
Rothhaar, Paul M.; Moerder, Daniel D.; Lim, Kyong B.
2008-01-01
Angular bias momentum offers significant stability augmentation for hovering flight vehicles. The reliance of the vehicle on thrust vectoring for agility and disturbance rejection is greatly reduced with significant levels of stored angular momentum in the system. A methodical procedure for bias momentum sizing has been developed in previous studies. This current study provides groundwork for experimental validation of that method using an experimental vehicle called the Dual-Spin Test Device, a thrust-levitated platform. Using measured data the vehicle's thrust vectoring units are modeled and a gust environment is designed and characterized. Control design is discussed. Preliminary experimental results of the vehicle constrained to three rotational degrees of freedom are compared to simulation for a case containing no bias momentum to validate the simulation. A simulation of a bias momentum dominant case is presented.
Small, J R
1993-01-01
This paper is a study into the effects of experimental error on the estimated values of flux control coefficients obtained using specific inhibitors. Two possible techniques for analysing the experimental data are compared: a simple extrapolation method (the so-called graph method) and a non-linear function fitting method. For these techniques, the sources of systematic errors are identified and the effects of systematic and random errors are quantified, using both statistical analysis and numerical computation. It is shown that the graph method is very sensitive to random errors and, under all conditions studied, that the fitting method, even under conditions where the assumptions underlying the fitted function do not hold, outperformed the graph method. Possible ways of designing experiments to minimize the effects of experimental errors are analysed and discussed. PMID:8257434
Statistical tools for transgene copy number estimation based on real-time PCR.
Yuan, Joshua S; Burris, Jason; Stewart, Nathan R; Mentewab, Ayalew; Stewart, C Neal
2007-11-01
As compared with traditional transgene copy number detection technologies such as Southern blot analysis, real-time PCR provides a fast, inexpensive and high-throughput alternative. However, the real-time PCR based transgene copy number estimation tends to be ambiguous and subjective stemming from the lack of proper statistical analysis and data quality control to render a reliable estimation of copy number with a prediction value. Despite the recent progresses in statistical analysis of real-time PCR, few publications have integrated these advancements in real-time PCR based transgene copy number determination. Three experimental designs and four data quality control integrated statistical models are presented. For the first method, external calibration curves are established for the transgene based on serially-diluted templates. The Ct number from a control transgenic event and putative transgenic event are compared to derive the transgene copy number or zygosity estimation. Simple linear regression and two group T-test procedures were combined to model the data from this design. For the second experimental design, standard curves were generated for both an internal reference gene and the transgene, and the copy number of transgene was compared with that of internal reference gene. Multiple regression models and ANOVA models can be employed to analyze the data and perform quality control for this approach. In the third experimental design, transgene copy number is compared with reference gene without a standard curve, but rather, is based directly on fluorescence data. Two different multiple regression models were proposed to analyze the data based on two different approaches of amplification efficiency integration. Our results highlight the importance of proper statistical treatment and quality control integration in real-time PCR-based transgene copy number determination. These statistical methods allow the real-time PCR-based transgene copy number estimation to be more reliable and precise with a proper statistical estimation. Proper confidence intervals are necessary for unambiguous prediction of trangene copy number. The four different statistical methods are compared for their advantages and disadvantages. Moreover, the statistical methods can also be applied for other real-time PCR-based quantification assays including transfection efficiency analysis and pathogen quantification.
The Design and Implementation of Adsorptive Removal of Cu(II) from Leachate Using ANFIS
Turan, Nurdan Gamze; Ozgonenel, Okan
2013-01-01
Clinoptilolite was investigated for the removal of Cu(II) ions from industrial leachate. Adaptive neural fuzzy interface system (ANFIS) was used for modeling the batch experimental system and predicting the optimal input values, that is, initial pH, adsorbent dosage, and contact time. Experiments were studied under laboratory batch and fixed bed conditions. The outcomes of suggested ANFIS modeling were then compared to a full factorial experimental design (23), which was utilized to assess the effect of three factors on the adsorption of Cu(II) ions in aqueous leachate of industrial waste. It was observed that the optimized parameters are almost close to each other. The highest removal efficiency was found as about 93.65% at pH 6, adsorbent dosage 11.4 g/L, and contact time 33 min for batch conditions of 23 experimental design and about 90.43% at pH 5, adsorbent dosage 15 g/L and contact time 35 min for batch conditions of ANFIS. The results show that clinoptilolite is an efficient sorbent and ANFIS, which is easy to implement and is able to model the batch experimental system. PMID:23844405
Rahmati, Nazanin Fatemeh; Mazaheri Tehrani, Mostafa
2014-09-01
Emulsifiers of different structures and functionalities are important ingredients usually used in baking cakes with satisfactory properties. In this study, three emulsifiers including distilled glycerol mono stearate (DGMS), lecithin and sorbitan mono stearate (SMS) were used to bake seven eggless cakes containing soy milk and optimization was performed by using mixture experimental design to produce an eggless cake sample with optimized properties. Physical properties of cake batters (viscosity, specific gravity and stability), cake quality parameters (moisture loss, density, specific volume, volume index, contour, symmetry, color and texture) and sensory attributes of eggless cakes were analyzed to investigate functional potential of the emulsifiers and results were compared with those of control cake containing egg. Almost in all cases emulsifiers, compared to the control cake, changed properties of eggless cakes significantly. Regarding models of different response variables (except for some properties) and their high R(2) (99.51-100), it could be concluded that models obtained by mixture design were significantly fitted for the studied responses.
Analysis of Test Case Computations and Experiments for the First Aeroelastic Prediction Workshop
NASA Technical Reports Server (NTRS)
Schuster, David M.; Heeg, Jennifer; Wieseman, Carol D.; Chwalowski, Pawel
2013-01-01
This paper compares computational and experimental data from the Aeroelastic Prediction Workshop (AePW) held in April 2012. This workshop was designed as a series of technical interchange meetings to assess the state of the art of computational methods for predicting unsteady flowfields and static and dynamic aeroelastic response. The goals are to provide an impartial forum to evaluate the effectiveness of existing computer codes and modeling techniques to simulate aeroelastic problems and to identify computational and experimental areas needing additional research and development. Three subject configurations were chosen from existing wind-tunnel data sets where there is pertinent experimental data available for comparison. Participant researchers analyzed one or more of the subject configurations, and results from all of these computations were compared at the workshop.
The high velocity impact loading on symmetrical and woven hybrid composite laminates
NASA Astrophysics Data System (ADS)
Jin, Martin; Richardson, Mel; Zhang, Zhong Yi
2007-07-01
Space structures use fibre composite materials, due to their lightweight. This paper examines the impact response of symmetrical and hybrid composite laminates. Special attention is given to the stacking sequences used. The experimental study of structures has always provided a major contribution to our understanding. Even with the formidable growth in the use and capacity of computing power the need for experimental measurement is as compelling as ever. The design of hybrid composite structures is complicated by the number of design variables and the interaction of the constituents is the composite system. Since it is desirable to experimentally test the design and it is not practical to test a full scale model, the structural/material similitude concept is used to create a small scale model with a similar structural response. In the current study, experimental investigations were carried out to determine the response of four different combinations of hybrid laminates to low-velocity impact loading using an instrumented impact testing machine. Hybrid laminates were fabricated with twill weave carbon fabric and plain weave S2-glass fabric using vacuum assisted resin molding process with SC-15 epoxy resin system. Response of carbon/epoxy and glass/epoxy laminates was also investigated to compare with that of hybrid samples. Square laminates of size 100 mm and nominal thickness of 3 mm were subjected to low-velocity impact loading at four energy levels of 10, 20, 30 and 40 J. Results of the study indicate that there is considerable improvement in the load carrying capability of hybrid composites as compared to carbon/epoxy laminates with slight reduction in stiffness.
Experimental Study of under-platform Damper Kinematics in Presence of Blade Dynamics
NASA Astrophysics Data System (ADS)
Botto, D.; Gastaldi, C.; Gola, M. M.; Umer, M.
2018-01-01
Among the different devices used in the aerospace industries under-platform dampers are widely used in turbo engines to mitigate the blade vibration. Nevertheless, the damper behaviour is not easy to simulate and engineers have been working in order to improve the accuracy with which theoretical contact models predict the damper behaviour. Majority of the experimental setups collect experimental data in terms of blade amplitude reduction which do not increase the knowledge about the damper dynamics and therefore the uncertainty on the damper behaviour remains a big issue. In this paper, a novel test rig has been purposely designed to accommodate a single blade and two under-platform dampers to deeply investigate the damper-blade interactions. In this test bench, a contact force measuring system was designed to extensively measure the damper contact forces. Damper kinematics is rebuilt by using the relative displacement measured between damper and blade. This paper describes the concept behind the new approach, shows the details of new test rig and discusses experimental results by comparing with previously measured results on an old experimental setup.
Graphical Models for Quasi-Experimental Designs
ERIC Educational Resources Information Center
Kim, Yongnam; Steiner, Peter M.; Hall, Courtney E.; Su, Dan
2016-01-01
Experimental and quasi-experimental designs play a central role in estimating cause-effect relationships in education, psychology, and many other fields of the social and behavioral sciences. This paper presents and discusses the causal graphs of experimental and quasi-experimental designs. For quasi-experimental designs the authors demonstrate…
Experiencing Experimentation and Project Design.
ERIC Educational Resources Information Center
Demchik, Michael J.
2001-01-01
Introduces the pea plant experiment targeted to determine the effects of Knop's solution, a solution containing all the necessary minerals, on plant growth. Compares two groups of pea plants, one treated with Knop's solution and one treated with demineralized water. (YDS)
Common Mechanism Underlies Repeated Evolution of Extreme Pollution Tolerance
Human alterations to the environment can exert strong evolutionary pressures, yet contemporary adaptation to human-mediated stressors is rarely documented in wild populations. A common-garden experimental design was coupled with comparative transcriptomics to discover evolved me...
Quantifying Astronaut Tasks: Robotic Technology and Future Space Suit Design
NASA Technical Reports Server (NTRS)
Newman, Dava
2003-01-01
The primary aim of this research effort was to advance the current understanding of astronauts' capabilities and limitations in space-suited EVA by developing models of the constitutive and compatibility relations of a space suit, based on experimental data gained from human test subjects as well as a 12 degree-of-freedom human-sized robot, and utilizing these fundamental relations to estimate a human factors performance metric for space suited EVA work. The three specific objectives are to: 1) Compile a detailed database of torques required to bend the joints of a space suit, using realistic, multi- joint human motions. 2) Develop a mathematical model of the constitutive relations between space suit joint torques and joint angular positions, based on experimental data and compare other investigators' physics-based models to experimental data. 3) Estimate the work envelope of a space suited astronaut, using the constitutive and compatibility relations of the space suit. The body of work that makes up this report includes experimentation, empirical and physics-based modeling, and model applications. A detailed space suit joint torque-angle database was compiled with a novel experimental approach that used space-suited human test subjects to generate realistic, multi-joint motions and an instrumented robot to measure the torques required to accomplish these motions in a space suit. Based on the experimental data, a mathematical model is developed to predict joint torque from the joint angle history. Two physics-based models of pressurized fabric cylinder bending are compared to experimental data, yielding design insights. The mathematical model is applied to EVA operations in an inverse kinematic analysis coupled to the space suit model to calculate the volume in which space-suited astronauts can work with their hands, demonstrating that operational human factors metrics can be predicted from fundamental space suit information.
Low Cost Gas Turbine Off-Design Prediction Technique
NASA Astrophysics Data System (ADS)
Martinjako, Jeremy
This thesis seeks to further explore off-design point operation of gas turbines and to examine the capabilities of GasTurb 12 as a tool for off-design analysis. It is a continuation of previous thesis work which initially explored the capabilities of GasTurb 12. The research is conducted in order to: 1) validate GasTurb 12 and, 2) predict off-design performance of the Garrett GTCP85-98D located at the Arizona State University Tempe campus. GasTurb 12 is validated as an off-design point tool by using the program to predict performance of an LM2500+ marine gas turbine. Haglind and Elmegaard (2009) published a paper detailing a second off-design point method and it includes the manufacturer's off-design point data for the LM2500+. GasTurb 12 is used to predict off-design point performance of the LM2500+ and compared to the manufacturer's data. The GasTurb 12 predictions show good correlation. Garrett has published specification data for the GTCP85-98D. This specification data is analyzed to determine the design point and to comment on off-design trends. Arizona State University GTCP85-98D off-design experimental data is evaluated. Trends presented in the data are commented on and explained. The trends match the expected behavior demonstrated in the specification data for the same gas turbine system. It was originally intended that a model of the GTCP85-98D be constructed in GasTurb 12 and used to predict off-design performance. The prediction would be compared to collected experimental data. This is not possible because the free version of GasTurb 12 used in this research does not have a module to model a single spool turboshaft. This module needs to be purchased for this analysis.
NASA Astrophysics Data System (ADS)
Qiu, Zhi-cheng; Wang, Xian-feng; Zhang, Xian-Min; Liu, Jin-guo
2018-07-01
A novel non-contact vibration measurement method using binocular vision sensors is proposed for piezoelectric flexible hinged plate. Decoupling methods of the bending and torsional low frequency vibration on measurement and driving control are investigated, using binocular vision sensors and piezoelectric actuators. A radial basis function neural network controller (RBFNNC) is designed to suppress both the larger and the smaller amplitude vibrations. To verify the non-contact measurement method and the designed controller, an experimental setup of the flexible hinged plate with binocular vision is constructed. Experiments on vibration measurement and control are conducted by using binocular vision sensors and the designed RBFNNC controllers, compared with the classical proportional and derivative (PD) control algorithm. The experimental measurement results demonstrate that the binocular vision sensors can detect the low-frequency bending and torsional vibration effectively. Furthermore, the designed RBF can suppress the bending vibration more quickly than the designed PD controller owing to the adjustment of the RBF control, especially for the small amplitude residual vibrations.
Design calculations for NIF convergent ablator experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Callahan, Debra; Leeper, Ramon Joe; Spears, B. K.
2010-11-01
Design calculations for NIF convergent ablator experiments will be described. The convergent ablator experiments measure the implosion trajectory, velocity, and ablation rate of an x-ray driven capsule and are a important component of the U. S. National Ignition Campaign at NIF. The design calculations are post-processed to provide simulations of the key diagnostics: (1) Dante measurements of hohlraum x-ray flux and spectrum, (2) streaked radiographs of the imploding ablator shell, (3) wedge range filter measurements of D-He3 proton output spectra, and (4) GXD measurements of the imploded core. The simulated diagnostics will be compared to the experimental measurements to providemore » an assessment of the accuracy of the design code predictions of hohlraum radiation temperature, capsule ablation rate, implosion velocity, shock flash areal density, and x-ray bang time. Post-shot versions of the design calculations are used to enhance the understanding of the experimental measurements and will assist in choosing parameters for subsequent shots and the path towards optimal ignition capsule tuning.« less
Analysis and Design of Rotors at Ultra-Low Reynolds Numbers
NASA Technical Reports Server (NTRS)
Kunz, Peter J.; Strawn, Roger C.
2003-01-01
Design tools have been developed for ultra-low Reynolds number rotors, combining enhanced actuator-ring / blade-element theory with airfoil section data based on two-dimensional Navier-Stokes calculations. This performance prediction method is coupled with an optimizer for both design and analysis applications. Performance predictions from these tools have been compared with three-dimensional Navier Stokes analyses and experimental data for a 2.5 cm diameter rotor with chord Reynolds numbers below 10,000. Comparisons among the analyses and experimental data show reasonable agreement both in the global thrust and power required, but the spanwise distributions of these quantities exhibit significant deviations. The study also reveals that three-dimensional and rotational effects significantly change local airfoil section performance. The magnitude of this issue, unique to this operating regime, may limit the applicability of blade-element type methods for detailed rotor design at ultra-low Reynolds numbers, but these methods are still useful for evaluating concept feasibility and rapidly generating initial designs for further analysis and optimization using more advanced tools.
Experimental evaluation of a translating nozzle sidewall radial turbine
NASA Technical Reports Server (NTRS)
Roelke, Richard J.; Rogo, Casimir
1987-01-01
An experimental performance evaluation was made of two movable sidewall variable area radial turbines. The turbine designs were representative of the gas generator turbine of a variable flow capacity rotorcraft engine. The first turbine was an uncooled design while the second turbine had a cooled nozzle but an uncooled rotor. The cooled nozzle turbine was evaluated both with and without coolant flow. The test results showed that the movable nozzle wall is a viable and efficient means to effectively control the flow capacity of a radial turbine. Peak efficiencies of the second turbine with and without nozzle coolant were 86.5 and 88 percent respectively. These values are comparable to pivoting vane variable geometry turbines; however, the decrease in efficiency as the flow was varied from the design value was much less for the movable wall turbine. Several design improvements which should increase the turbine efficiency one or two more points are identified. These design improvements include reduced leakage losses and relocation of the vane coolant ejection holes to reduce mainstream disturbance.
Patil, Ratnadeep; Gresnigt, Marco M M; Mahesh, Kavita; Dilbaghi, Anjali; Cune, Marco S
2017-07-01
To correlate patients' satisfaction and dentists' observations regarding two abutment designs used for single crowns in the esthetic zone: a divergent one (control) and a curved one (experimental), with special emphasis on muco-gingival esthetics. Twenty-six patients with nonadjacent missing teeth in the esthetic zone were enrolled in a randomized clinical trial (within-subject comparison). Two implants placed in each were restored using abutments of different geometry. Patients' appreciation was assessed on a visual analog scale (VAS) by recording answers to three questions, and dentists' appreciation was determined by means of the Pink Esthetic Score (PES) at T0 (crown cementation, baseline) and at T12 (1 year post-cementation). ANOVA with post hoc analysis was used to identify differences between groups and at different moments in time. Pearson correlations were calculated between all variables, both at T0 and at T12. No statistically significant differences were found at any time between the control and experimental abutment design, either for the PES or for the VAS score. PES slightly improved after 1 year, as did the VAS rating related to functioning with the implant-crown compared to the natural teeth. All PES and VAS scores demonstrated highly significant correlation. Both patient satisfaction and professional appreciation of muco-gingival conditions after single implant treatment in the esthetic zone were high; however, the curved, experimental abutment design performed no better than the conventional, divergent type. Curved abutment design does not significantly impact crown or gingival esthetics as assessed by PES and VAS scored by dentists and patients, respectively. © 2016 by the American College of Prosthodontists.
1989-09-30
to accommodate peripherally non -uniform flow modelling free of experimental uncertainties. It was effects (blockage) in the throughflow code...combines that experimental control functions with a detail in this thesis, and the results of a computer menu-driven, diagnostic subsystem to ensure...equations and design a complete (DSL) for both linear and non -linear models and automatic control system for the three dimensional compared. Cross
High Gain and Wide Range Time Amplifier Using Inverter Delay Chain in SR Latches
NASA Astrophysics Data System (ADS)
Lee, Jaejun; Lee, Sungho; Song, Yonghoon; Nam, Sangwook
This paper presents a time amplifier design that improves time resolution using an inverter chain delay in SR latches. Compared with the conventional design, the proposed time amplifier has better characteristics such as higher gain, wide range, and small die size. It is implemented using 0.13µm standard CMOS technology and the experimental results agree well with the theory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... comparative data to other methods and SRM materials are presented in Reference 23 of Section 16.0. 13... Plasma, Anal. Chem. 52:1965, 1980. 20. Deming, S.N. and S.L. Morgan. Experimental Design for Quality and... Statistical Designs, 9941 Rowlett, Suite 6, Houston, TX 77075, 1989. 21. Winefordner, J.D., Trace Analysis...
Code of Federal Regulations, 2013 CFR
2013-07-01
... comparative data to other methods and SRM materials are presented in Reference 23 of Section 16.0. 13... Plasma, Anal. Chem. 52:1965, 1980. 20. Deming, S.N. and S.L. Morgan. Experimental Design for Quality and... Statistical Designs, 9941 Rowlett, Suite 6, Houston, TX 77075, 1989. 21. Winefordner, J.D., Trace Analysis...
Code of Federal Regulations, 2012 CFR
2012-07-01
... comparative data to other methods and SRM materials are presented in Reference 23 of Section 16.0. 13... Plasma, Anal. Chem. 52:1965, 1980. 20. Deming, S.N. and S.L. Morgan. Experimental Design for Quality and... Statistical Designs, 9941 Rowlett, Suite 6, Houston, TX 77075, 1989. 21. Winefordner, J.D., Trace Analysis...
ERIC Educational Resources Information Center
Harniss, Mark K.; Caros, Jennifer; Gersten, Russell
2007-01-01
We used randomized controlled trials to compare the impact of the designs of 2 United States history textbooks on the content acquisition and behavior of 8th-grade students identified for special education services or identified as low achieving. We also investigated whether teachers differed in their use of instructional activities and…
ERIC Educational Resources Information Center
Lorch, Robert F., Jr.; Lorch, Elizabeth P.; Freer, Benjamin Dunham; Dunlap, Emily E.; Hodell, Emily C.; Calderhead, William J.
2014-01-01
Students (n = 1,069) from 60 4th-grade classrooms were taught the control of variables strategy (CVS) for designing experiments. Half of the classrooms were in schools that performed well on a state-mandated test of science achievement, and half were in schools that performed relatively poorly. Three teaching interventions were compared: an…
ERIC Educational Resources Information Center
BROWN, O. ROBERT, JR.
THE EXPERIMENTAL DESIGN IN THIS STUDY OF THE USE OF PROGRAMED MATERIALS TO TEACH HIGH SCHOOL MATHEMATICS DESIGNATED FOUR GROUPS--A CONTROL GROUP TAUGHT CONVENTIONALLY BY TEACHERS TRAINED TO USE PROGRAMED MATERIALS, A "PURE" GROUP USING PROGRAMED MATERIALS ONLY, AND "ANTICIPATING" AND "FOLLOWING" GROUPS THAT USED…
Miniaturized dielectric waveguide filters
NASA Astrophysics Data System (ADS)
Sandhu, Muhammad Y.; Hunter, Ian C.
2016-10-01
Design techniques for a new class of integrated monolithic high-permittivity ceramic waveguide filters are presented. These filters enable a size reduction of 50% compared to air-filled transverse electromagnetic filters with the same unloaded Q-factor. Designs for Chebyshev and asymmetric generalised Chebyshev filter and a diplexer are presented with experimental results for an 1800 MHz Chebyshev filter and a 1700 MHz generalised Chebyshev filter showing excellent agreement with theory.
ERIC Educational Resources Information Center
Melendez Alicea, Juan
1992-01-01
Presents steps taken in designing, justifying, and implementing an experimental study designed to investigate the effectiveness of distance education as a methodology for developing thinking skills. A discussion reviews major findings of the study by comparing student experiences from multimedia distance education and student experiences from…
NASA Technical Reports Server (NTRS)
Suder, Kenneth L.
1996-01-01
A detailed experimental investigation to understand and quantify the development of loss and blockage in the flow field of a transonic, axial flow compressor rotor has been undertaken. Detailed laser anemometer measurements were acquired upstream, within, and downstream of a transonic, axial compressor rotor operating at design and off-design conditions. The rotor was operated at 100%, 85%, 80%, and 60% of design speed which provided inlet relative Mach numbers at the blade tip of 1.48, 1.26, 1.18, and 0.89 respectively. At design speed the blockage is evaluated ahead of the rotor passage shock, downstream of the rotor passage shock, and near the trailing edge of the blade row. The blockage is evaluated in the core flow area as well as in the casing endwall region. Similarly at pm speed conditions for the cases of (1) where the rotor passage shock is much weaker than that at design speed and (2) where there is no rotor passage shock, the blockage and loss are evaluated and compared to the results at design speed. Specifically, the impact of the rotor passage shock on the blockage and loss development, pertaining to both the shock/boundary layer interactions and the shock/tip clearance flow interactions, is discussed. In addition, the blockage evaluated from the experimental data is compared to (1) an existing correlation of blockage development which was based on computational results, and (2) computational results on a limited basis. The results indicate that for this rotor the blockage in the endwall region is 2-3 times that of the core flow region and the blockage in the core flow region more than doubles when the shock strength is sufficient to separate the suction surface boundary layer. The distribution of losses in the care flow region indicate that the total loss is primarily comprised of the shock loss when the shock strength is not sufficient to separate the suction surface boundary layer. However, when the shock strength is sufficient to separate the suction surface boundary layer, the profile loss is comparable to the shock loss and can exceed the shock loss.
Sovány, Tamás; Tislér, Zsófia; Kristó, Katalin; Kelemen, András; Regdon, Géza
2016-09-01
The application of the Quality by Design principles is one of the key issues of the recent pharmaceutical developments. In the past decade a lot of knowledge was collected about the practical realization of the concept, but there are still a lot of unanswered questions. The key requirement of the concept is the mathematical description of the effect of the critical factors and their interactions on the critical quality attributes (CQAs) of the product. The process design space (PDS) is usually determined by the use of design of experiment (DoE) based response surface methodologies (RSM), but inaccuracies in the applied polynomial models often resulted in the over/underestimation of the real trends and changes making the calculations uncertain, especially in the edge regions of the PDS. The completion of RSM with artificial neural network (ANN) based models is therefore a commonly used method to reduce the uncertainties. Nevertheless, since the different researches are focusing on the use of a given DoE, there is lack of comparative studies on different experimental layouts. Therefore, the aim of present study was to investigate the effect of the different DoE layouts (2 level full factorial, Central Composite, Box-Behnken, 3 level fractional and 3 level full factorial design) on the model predictability and to compare model sensitivities according to the organization of the experimental data set. It was revealed that the size of the design space could differ more than 40% calculated with different polynomial models, which was associated with a considerable shift in its position when higher level layouts were applied. The shift was more considerable when the calculation was based on RSM. The model predictability was also better with ANN based models. Nevertheless, both modelling methods exhibit considerable sensitivity to the organization of the experimental data set, and the use of design layouts is recommended, where the extreme values factors are more represented. Copyright © 2016 Elsevier B.V. All rights reserved.
Effect of subliminal stimuli on consumer behavior: negative evidence.
George, S G; Jennings, L B
1975-12-01
The study corrected methodological weaknesses found in previous experiments designed to test the contentions of motivational research theorists that subliminal stimulation can affect buying behavior. The words "Hershey's Chocolate" were presented to a group of 18 experimental Ss below a forced-choice detection threshold. The 19 control Ss had a blank slide superimposed over the same background media. In a highly controlled buying situation neither experimental nor control Ss purchased Hershey's products, but on comparable chocolate products, the experimental Ss bought 5 and the control Ss, 3. A second study tested 15 experimental and 12 control Ss with the stimulus presented just below a recognition threshold. No experimental Ss bought Hershey's; two control Ss did. No support was found for the claims of motivational research theorists.
Design, implementation and control of a magnetic levitation device
NASA Astrophysics Data System (ADS)
Shameli, Ehsan
Magnetic levitation technology has shown a great deal of promise for micromanipulation tasks. Due to the lack of mechanical contact, magnetic levitation systems are free of problems caused by friction, wear, sealing and lubrication. These advantages have made magnetic levitation systems a great candidate for clean room applications. In this thesis, a new large gap magnetic levitation system is designed, developed and successfully tested. The system is capable of levitating a 6.5(gr) permanent magnet in 3D space with an air gap of approximately 50(cm) with the traveling range of 20x20x30 mm3. The overall positioning accuracy of the system is 60mum. With the aid of finite elements method, an optimal geometry for the magnetic stator is proposed. Also, an energy optimization approach is utilized in the design of the electromagnets. In order to facilitate the design of various controllers for the system, a mathematical model of the magnetic force experienced by the levitated object is obtained. The dynamic magnetic force model is determined experimentally using frequency response system identification. The response of the system components including the power amplifiers, and position measurement system are also considered in the development of the force model. The force model is then employed in the controller design for the magnetic levitation device. Through a modular approach, the controller design for the 3D positioning system is started with the controller design for the vertical direction, i.e. z, and then followed by the controller design in the horizontal directions, i.e. x and y. For the vertical direction, several controllers such as PID, feed forward and feedback linearization are designed and their performances are compared. Also a control command conditioning method is introduced as a solution to increase the control performance and the results of the proposed controller are compared with the other designs. Experimental results showed that for the magnetic levitation system, the feedback linearization controller has the shortest settling time and is capable of reducing the positioning error to RMS value of 11.56mum. The force model was also utilized in the design of a model reference adaptive feedback linearization (MRAFL) controller for the z direction. For this case, the levitated object is a small microrobot equipped with a remote controlled gripper weighting approximately 28(gr). Experimental results showed that the MRAFL controller enables the micro-robot to pick up and transport a payload as heavy as 30% of its own weight without a considerable effect on its positioning accuracy. In the presence of the payload, the MRAFL controller resulted in a RMS positioning error of 8microm compared with 27.9mum of the regular feedback linearization controller. For the horizontal position control of the system, a mathematical formula for distributing the electric currents to the multiple electromagnets of the system was proposed and a PID control approach was implemented to control the position of the levitated object in the xy-plane. The control system was experimentally tested in tracking circular and spiral trajectories with overall positioning accuracy of 60mum. Also, a new mathematical approach is presented for the prediction of magnetic field distribution in the horizontal direction. The proposed approach is named the pivot point method and is capable of predicting the two dimensional position of the levitated object in a given vertical plane for an arbitrary current distribution in the electromagnets of the levitation system. Experimental results showed that the proposed method is capable of predicting the location of the levitated object with less than 10% error.
Erfanian, Parham; Tenzif, Siamak; Guerriero, Rocco C
2004-01-01
Objective To determine the effects of a semi-customized experimental cervical pillow on symptomatic adults with chronic neck pain (with and without headache) during a four week study. Design A randomized controlled trial. Sample size Thirty-six adults were recruited for the trial, and randomly assigned to experimental or non-experimental groups of 17 and 19 participants respectively. Subjects Adults with chronic biomechanical neck pain who were recruited from the Canadian Memorial Chiropractic College (CMCC) Walk-in Clinic. Outcome measures Subjective findings were assessed using a mail-in self-report daily pain diary, and the CMCC Neck Disability Index (NDI). Statistical analysis Using repeated measure analysis of variance weekly NDI scores, average weekly AM and PM pain scores between the experimental and non-experimental groups were compared throughout the study. Results The experimental group had statistically significant lower NDI scores (p < 0.05) than the non-experimental group. The average weekly AM scores were lower and statistically significant (p < 0.05) in the experimental group. The PM scores in the experimental group were lower but not statistically significant than the other group. Conclusions The study results show that compared to conventional pillows, this experimental semi-customized cervical pillow was effective in reducing low-level neck pain intensity, especially in the morning following its use in a 4 week long study. PMID:17549216
Design variables for mechanical properties of bone tissue scaffolds.
Howk, Daniel; Chu, Tien-Min G
2006-01-01
The reconstruction of segmental defect in long bone is a clinical challenge. Multiple surgeries are typically required to restore the structure and function of the affected defect site. In order to overcome this defect a biodegradable bone tissue engineering scaffold is used. This scaffold acts as a carrier of proteins and growth factors, while also supporting the load that the bone would normally sustain, until the natural bone can regenerate in its place. Work was done to optimize an existing solid free-form scaffold design. The goal of the optimization was to increase the porosity of the scaffold while maintaining the strength of a previously-tested prototype design. With this in mind, eight new designs were created. These designs were drawn using CAD software and then through the use of finite element analysis the theoretical ultimate compressive strength of each design was obtained. Each scaffold design was constructed by casting a thermal-curable poly(propylene fumarate)/tricalcium phosphate (PPF/TCP) suspension into wax molds fabricated on inkjet printing rapid prototyping machine. The constructs were then experimentally tested by applying a uniaxial compressive load. The theoretical and experimental values of ultimate compressive strength and specific strength of each design were compared. Theoretically, the best scaffold design produced from this work improved upon the current design by increasing the porosity by 46% and also increasing the ultimate compressive strength by 27%. The experimental data was found to match the theoretical strength in four designs, but deviate from the theoretical strength in five designs. The reasons for the deviations and their relation to the rapid prototyping manufacturing technique were discussed. The results of this work show that it is possible to increase the porosity and strength of a bone tissue engineering scaffold through simple iterations in architectural design.
Song, Yang; Zhao, Yi-jiao; Sun, Yu-chun; Lü, Pei-jun; Wang, Yong
2013-09-01
To evaluate the design and manufacture accuracy of a domestic computer aided design (CAD) and computer aided manufacture (CAM) system, and to compare it with similar foreign products. Thirty models of posterior-teeth-single-crown preparations were collected, and STL data of these preparations was collected by Denmark 3Shape scanner. Three copings were made for each preparation, the one designed and manufactured using commercial CAD/CAM system (3Shape CAD software and Wieland T1 CAM equipment) was assigned into control group T0, the one designed and manufactured using domestic CAD software (developed by Peking University School and Hospital of Stomatology and Nanjing University of Aeronautics and Astronautics) and Wieland T1 CAM equipment was assigned into experimental group TCAD for design accuracy evaluation, and the one designed and manufactured using 3Shape CAD software and domestic CAM equipment (developed by Peking University School and Hospital of Stomatology, Tsinghua University and ShanDong XinHua Incorporated Company of medical apparatus and instruments) was assigned into experimental group TCAM for manufacture accuracy evaluation. Finally, the marginal fitness were compared and evaluated by using 3D & Profile measurement microscope laser. The marginal fitness of TCAD was 27.98 (19.10, 46.57) µm in buccal, 32.67 (20.65, 50.82) µm in lingual, 27.38 (22.53, 52.61) µm in mesial, 29.50 (22.68, 53.65) µm in distal; of TCAM was 21.69 (15.87, 30.21) µm in buccal, 18.51 (13.50, 22.51) µm in lingual, 19.15 (15.42, 26.89) µm in mesial, 22.77 (18.58, 32.15) µm in distal; and there were no statistical differences compared with T0 [20.16 (17.16, 48.00) µm in buccal, 21.51 (17.05, 28.31) µm in lingual, 23.54 (17.89, 30.04) µm in mesial and 23.94 (17.93, 28.19) µm in distal] except lingual data of TCAD. The design and machining precision of this domestic CAD/CAM system is at the same level of those comparable foreign products.
ERIC Educational Resources Information Center
Yilmaz, Diba; Tekkaya, Ceren; Sungur, Semra
2011-01-01
The present study examined the comparative effects of a prediction/discussion-based learning cycle, conceptual change text (CCT), and traditional instructions on students' understanding of genetics concepts. A quasi-experimental research design of the pre-test-post-test non-equivalent control group was adopted. The three intact classes, taught by…
ERIC Educational Resources Information Center
Petko, Dominik; Egger, Nives; Graber, Marc
2014-01-01
The goal of this study was to compare how weblogs and traditional handwritten reflective learning protocols compare regarding the use of cognitive and metacognitive strategies for knowledge acquisition as well as learning gains in secondary school students. The study used a quasi-experimental control group design with repeated measurements…
ATLAS, an integrated structural analysis and design system. Volume 5: System demonstration problems
NASA Technical Reports Server (NTRS)
Samuel, R. A. (Editor)
1979-01-01
One of a series of documents describing the ATLAS System for structural analysis and design is presented. A set of problems is described that demonstrate the various analysis and design capabilities of the ATLAS System proper as well as capabilities available by means of interfaces with other computer programs. Input data and results for each demonstration problem are discussed. Results are compared to theoretical solutions or experimental data where possible. Listings of all input data are included.
Sung, Ki Wol; Kang, Hye Seung; Nam, Ji Ran; Park, Mi Kyung; Park, Ji Hyeon
2018-04-01
This study aimed to estimate the effects of a health mentoring program on fasting blood sugar, total cholesterol, triglyceride, physical activity, self care behavior and social support changes among community-dwelling vulnerable elderly individuals with diabetes. A non-equivalent control group pre-post-test design was used. Participants were 70 community-dwelling vulnerable elderly individuals with diabetes. They were assigned to the experimental (n=30) or comparative (n=30) or control group (n=28). The experimental group participated in the health mentoring program, while the comparative group participated in health education program, the control group did not participate in any program. Data analyses involved a chi-square test, Fisher's exact test, a generalized linear model, and the Bonferroni correction, using SPSS 23.0. Compared to the control group, the experimental and comparative groups showed a significant decrease in fasting blood sugar, total cholesterol, and triglyceride. Compared to the comparative and control groups, the experimental group showed significant improvement in self care behavior. However, there were no statistical differences in physical activity or social support among the three groups. These findings indicate that the health mentoring program is an effective intervention for community-dwelling vulnerable elderly individuals with diabetes. This program can be used as an efficient strategy for diabetes self-management within this population. © 2018 Korean Society of Nursing Science.
Evaluation of mesoporous silicon thermal conductivity by electrothermal finite element simulation
2012-01-01
The aim of this work is to determine the thermal conductivity of mesoporous silicon (PoSi) by fitting the experimental results with simulated ones. The electrothermal response (resistance versus applied current) of differently designed test lines integrated onto PoSi/silicon substrates and the bulk were compared to the simulations. The PoSi thermal conductivity was the single parameter used to fit the experimental results. The obtained thermal conductivity values were compared with those determined from Raman scattering measurements, and a good agreement between both methods was found. This methodology can be used to easily determine the thermal conductivity value for various porous silicon morphologies. PMID:22849851
Ranking factors affecting emissions of GHG from incubated agricultural soils.
García-Marco, S; Ravella, S R; Chadwick, D; Vallejo, A; Gregory, A S; Cárdenas, L M
2014-07-01
Agriculture significantly contributes to global greenhouse gas (GHG) emissions and there is a need to develop effective mitigation strategies. The efficacy of methods to reduce GHG fluxes from agricultural soils can be affected by a range of interacting management and environmental factors. Uniquely, we used the Taguchi experimental design methodology to rank the relative importance of six factors known to affect the emission of GHG from soil: nitrate (NO 3 - ) addition, carbon quality (labile and non-labile C), soil temperature, water-filled pore space (WFPS) and extent of soil compaction. Grassland soil was incubated in jars where selected factors, considered at two or three amounts within the experimental range, were combined in an orthogonal array to determine the importance and interactions between factors with a L 16 design, comprising 16 experimental units. Within this L 16 design, 216 combinations of the full factorial experimental design were represented. Headspace nitrous oxide (N 2 O), methane (CH 4 ) and carbon dioxide (CO 2 ) concentrations were measured and used to calculate fluxes. Results found for the relative influence of factors (WFPS and NO 3 - addition were the main factors affecting N 2 O fluxes, whilst glucose, NO 3 - and soil temperature were the main factors affecting CO 2 and CH 4 fluxes) were consistent with those already well documented. Interactions between factors were also studied and results showed that factors with little individual influence became more influential in combination. The proposed methodology offers new possibilities for GHG researchers to study interactions between influential factors and address the optimized sets of conditions to reduce GHG emissions in agro-ecosystems, while reducing the number of experimental units required compared with conventional experimental procedures that adjust one variable at a time.
Ranking factors affecting emissions of GHG from incubated agricultural soils
García-Marco, S; Ravella, S R; Chadwick, D; Vallejo, A; Gregory, A S; Cárdenas, L M
2014-01-01
Agriculture significantly contributes to global greenhouse gas (GHG) emissions and there is a need to develop effective mitigation strategies. The efficacy of methods to reduce GHG fluxes from agricultural soils can be affected by a range of interacting management and environmental factors. Uniquely, we used the Taguchi experimental design methodology to rank the relative importance of six factors known to affect the emission of GHG from soil: nitrate (NO3−) addition, carbon quality (labile and non-labile C), soil temperature, water-filled pore space (WFPS) and extent of soil compaction. Grassland soil was incubated in jars where selected factors, considered at two or three amounts within the experimental range, were combined in an orthogonal array to determine the importance and interactions between factors with a L16 design, comprising 16 experimental units. Within this L16 design, 216 combinations of the full factorial experimental design were represented. Headspace nitrous oxide (N2O), methane (CH4) and carbon dioxide (CO2) concentrations were measured and used to calculate fluxes. Results found for the relative influence of factors (WFPS and NO3− addition were the main factors affecting N2O fluxes, whilst glucose, NO3− and soil temperature were the main factors affecting CO2 and CH4 fluxes) were consistent with those already well documented. Interactions between factors were also studied and results showed that factors with little individual influence became more influential in combination. The proposed methodology offers new possibilities for GHG researchers to study interactions between influential factors and address the optimized sets of conditions to reduce GHG emissions in agro-ecosystems, while reducing the number of experimental units required compared with conventional experimental procedures that adjust one variable at a time. PMID:25177207
Air flow through poppet valves
NASA Technical Reports Server (NTRS)
Lewis, G W; Nutting, E M
1920-01-01
Report discusses the comparative continuous flow characteristics of single and double poppet valves. The experimental data presented affords a direct comparison of valves, single and in pairs of different sizes, tested in a cylinder designed in accordance with current practice in aviation engines.
Experimental realization of noise-induced adiabaticity in nuclear magnetic resonance
NASA Astrophysics Data System (ADS)
Wang, Bi-Xue; Xin, Tao; Kong, Xiang-Yu; Wei, Shi-Jie; Ruan, Dong; Long, Gui-Lu
2018-04-01
The adiabatic evolution is the dynamics of an instantaneous eigenstate of a slowly varing Hamiltonian. Recently, an interesting phenomenon shows up that white noises can enhance and even induce adiabaticity, which is in contrast to previous perception that environmental noises always modify and even ruin a designed adiabatic passage. We experimentally realized a noise-induced adiabaticity in a nuclear magnetic resonance system. Adiabatic Hadamard gate and entangled state are demonstrated. The effect of noise on adiabaticity is experimentally exhibited and compared with the noise-free process. We utilized a noise-injected method, which can be applied to other quantum systems.
[Effects of a fall prevention program on falls in frail elders living at home in rural communities].
Yoo, Jae-Soon; Jeon, Mi Yang; Kim, Chul-Gyu
2013-10-01
This study was conducted to determine the effects of a fall prevention program on falls, physical function, psychological function, and home environmental safety in frail elders living at home in rural communities. The design of this study was a nonequivalent control group pre posttest design. The study was conducted from July to November, 2012 with 30 participants in the experimental group and 30 in the control group. Participants were registered at the public health center of E County. The prevention program on falls consisted of laughter therapy, exercise, foot care and education. The program was provided once a week for 8 weeks and each session lasted 80 minutes. The risk score for falls and depression in the experimental group decreased significantly compared with scores for the control group. Compliance with prevention behavior related to falls, knowledge score on falls, safety scores of home environment, physical balance, muscle strength of lower extremities, and self-efficacy for fall prevention significantly increased in the experimental group compared with the control group. These results suggest that the prevention program on falls is effective for the prevention of falls in frail elders living at home.
Experimental investigation on hard turning of AISI 4340 steel using cemented coated carbide insert
NASA Astrophysics Data System (ADS)
Pradeep Kumar, J.; Kishore, K. P.; Ranjith Kumar, M.; Saran Karthick, K. R.; Vishnu Gowtham, S.
2018-02-01
Hard turning is a developing technology that offers many potential advantages compared to grinding, which remains the standard finishing process for critical hardened surfaces. In this work, an attempt has been made to experimentally investigate hard turning of AISI 4340 steel under wet and dry condition using cemented coated carbide insert. Hardness of the workpiece material is tested using Brinell and Rockwell hardness testers. CNC LATHE and cemented coated carbide inserts of designation CNMG 120408 are used for conducting experimental trials. Significant cutting parameters like cutting speed, feed rate and depth of cut are considered as controllable input parameters and surface roughness (Ra), tool wear are considered as output response parameters. Design of experiments is carried out with the help of Taguchi’s L9 orthogonal array. Results of response parameters like surface roughness and tool wear under wet and dry condition are analysed. It is found that surface roughness and tool wear are higher under dry machining condition when compared to wet machining condition. Feed rate significantly influences the surface roughness followed by cutting speed. Depth of cut significantly influences the tool wear followed by cutting speed.
Zhang, Hui; Cowling, David W; Facer, Matthew
2017-12-01
Various health insurance benefit designs based on value-based purchasing have been promoted to steer patients to high-value providers, but little is known about the designs' relative effectiveness and underlying mechanisms. We compared the impact of two designs implemented by the California Public Employees' Retirement System on inpatient hospital total hip or knee replacement: a reference-based pricing design for preferred provider organizations (PPOs) and a centers-of-excellence design for health maintenance organizations (HMOs). Payment and utilization data for the procedures in the period 2008-13 were evaluated using pre-post and quasi-experimental designs at the system and health plan levels, adjusting for demographic characteristics, case-mix, and other confounders. We found that both designs prompted higher use of designated low-price high-quality facilities and reduced average replacement expenses per member at the plan and system levels. However, the designs used different routes: The reference-based pricing design reduced average replacement payments per case in PPOs by 26.7 percent in the first year, compared to HMOs, but did not lower PPO members' utilization rates. In contrast, the centers-of-excellence design lowered HMO members' utilization rates by 29.2 percent in the first year, compared to PPOs, but did not reduce HMO average replacement payments per case. The reference-based pricing design appears more suitable for reducing price variation, and the centers-of-excellence design for addressing variation in use.
An experimental SMI adaptive antenna array for weak interfering signals
NASA Technical Reports Server (NTRS)
Dilsavor, R. L.; Gupta, I. J.
1989-01-01
A modified sample matrix inversion (SMI) algorithm designed to increase the suppression of weak interference is implemented on an existing experimental array system. The algorithm itself is fully described as are a number of issues concerning its implementation and evaluation, such as sample scaling, snapshot formation, weight normalization, power calculation, and system calibration. Several experiments show that the steady state performance (i.e., many snapshots are used to calculate the array weights) of the experimental system compares favorably with its theoretical performance. It is demonstrated that standard SMI does not yield adequate suppression of weak interference. Modified SMI is then used to experimentally increase this suppression by as much as 13dB.
NASA Astrophysics Data System (ADS)
Patole, Pralhad B.; Kulkarni, Vivek V.
2018-06-01
This paper presents an investigation into the minimum quantity lubrication mode with nano fluid during turning of alloy steel AISI 4340 work piece material with the objective of experimental model in order to predict surface roughness and cutting force and analyze effect of process parameters on machinability. Full factorial design matrix was used for experimental plan. According to design of experiment surface roughness and cutting force were measured. The relationship between the response variables and the process parameters is determined through the response surface methodology, using a quadratic regression model. Results show how much surface roughness is mainly influenced by feed rate and cutting speed. The depth of cut exhibits maximum influence on cutting force components as compared to the feed rate and cutting speed. The values predicted from the model and experimental values are very close to each other.
Peer counseling in a culturally specific adolescent pregnancy prevention program.
Ferguson, S L
1998-08-01
This study evaluated the effects of peer counseling in a culturally specific adolescent pregnancy prevention program for African American females. A random pretest and multiple posttest experimental and comparison group design was used to obtain data on a sample of 63 female African American adolescents, ages 12 to 16, who lived in four public housing developments. Descriptive data and tests of significance revealed that none of the participants who received peer counseling became pregnant within three months of the intervention. Findings revealed a statistically significant increase in reproductive and other self-related knowledge topics among the experimental group when comparing pretest and eight-week posttest scores. Most participants had not had sexual intercourse; the average age of sexual onset was 12 years in the experimental group and 11 years in the controls. Designing and implementing culturally specific adolescent pregnancy prevention programs for adolescents younger than age 11 and/or before sexually active seems appropriate.
Lennon, Jay T
2011-06-01
A recent analysis revealed that most environmental microbiologists neglect replication in their science (Prosser, 2010). Of all peer-reviewed papers published during 2009 in the field's leading journals, slightly more than 70% lacked replication when it came to analyzing microbial community data. The paucity of replication is viewed as an 'endemic' and 'embarrassing' problem that amounts to 'bad science', or worse yet, as the title suggests, lying (Prosser, 2010). Although replication is an important component of experimental design, it is possible to do good science without replication. There are various quantitative techniques - some old, some new - that, when used properly, will allow environmental microbiologists to make strong statistical conclusions from experimental and comparative data. Here, I provide examples where unreplicated data can be used to test hypotheses and yield novel information in a statistically robust manner. © 2011 Society for Applied Microbiology and Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Kara, Yılmaz; Yeşilyurt, Selami
2008-02-01
The purpose of this study was to investigate the effects of tutorial and edutainment design of instructional software programs related to the "cell division" topic on student achievements, misconceptions and attitudes. An experimental research design including the cell division achievement test (CAT), the cell division concept test (CCT) and biology attitude scale (BAS) was applied at the beginning and at the end of the research. After the treatment, general achievement in CAT increased in favor of experimental groups. Instructional software programs also had the positive effect to the awareness of students' understandings to the general functions of mitosis and meiosis. However, the current study revealed that there were still some misconceptions in the experimental groups even after the treatment. It was also noticed that only using edutainment software program significantly changed students' attitudes towards biology.
Navarro-Fontestad, Carmen; González-Álvarez, Isabel; Fernández-Teruel, Carlos; Bermejo, Marival; Casabó, Vicente Germán
2012-01-01
The aim of the present work was to develop a new mathematical method for estimating the area under the curve (AUC) and its variability that could be applied in different preclinical experimental designs and amenable to be implemented in standard calculation worksheets. In order to assess the usefulness of the new approach, different experimental scenarios were studied and the results were compared with those obtained with commonly used software: WinNonlin® and Phoenix WinNonlin®. The results do not show statistical differences among the AUC values obtained by both procedures, but the new method appears to be a better estimator of the AUC standard error, measured as the coverage of 95% confidence interval. In this way, the new proposed method demonstrates to be as useful as WinNonlin® software when it was applicable. Copyright © 2011 John Wiley & Sons, Ltd.
A comparison of between- and within-subjects imitation designs.
Kressley, Regina A; Knopf, Monika
2006-12-01
Two experimental methods, which have dominated the study of declarative memory in preverbal children with imitation tasks, namely the deferred imitation and elicited imitation paradigm, differ in the amount of physical contact with test stimuli afforded infants prior to a test for long-term recall. The current study assessed effects of pre- and post-demonstration contact with test stimuli on deferred imitation of novel, single-step unrelated actions with multiple objects by 8(1/2)- and 10(1/2)-month-old infants (N=50). The rate of target action completion after a delay remained consistent at both ages across different conditions of prior contact with test stimuli. This study shows that a within-subjects baseline appraisal is valid within certain experimental parameters and offers a more economical alternative. The results show furthermore that different experimental designs utilized to assess deferred imitation are highly comparable for the first year despite differences in determining baseline.
Experimental parametric study of servers cooling management in data centers buildings
NASA Astrophysics Data System (ADS)
Nada, S. A.; Elfeky, K. E.; Attia, Ali M. A.; Alshaer, W. G.
2017-06-01
A parametric study of air flow and cooling management of data centers servers is experimentally conducted for different design conditions. A physical scale model of data center accommodating one rack of four servers was designed and constructed for testing purposes. Front and rear rack and server's temperatures distributions and supply/return heat indices (SHI/RHI) are used to evaluate data center thermal performance. Experiments were conducted to parametrically study the effects of perforated tiles opening ratio, servers power load variation and rack power density. The results showed that (1) perforated tile of 25% opening ratio provides the best results among the other opening ratios, (2) optimum benefit of cold air in servers cooling is obtained at uniformly power loading of servers (3) increasing power density decrease air re-circulation but increase air bypass and servers temperature. The present results are compared with previous experimental and CFD results and fair agreement was found.
NASA Astrophysics Data System (ADS)
Nishida, R. T.; Beale, S. B.; Pharoah, J. G.; de Haart, L. G. J.; Blum, L.
2018-01-01
This work is among the first where the results of an extensive experimental research programme are compared to performance calculations of a comprehensive computational fluid dynamics model for a solid oxide fuel cell stack. The model, which combines electrochemical reactions with momentum, heat, and mass transport, is used to obtain results for an established industrial-scale fuel cell stack design with complex manifolds. To validate the model, comparisons with experimentally gathered voltage and temperature data are made for the Jülich Mark-F, 18-cell stack operating in a test furnace. Good agreement is obtained between the model and experiment results for cell voltages and temperature distributions, confirming the validity of the computational methodology for stack design. The transient effects during ramp up of current in the experiment may explain a lower average voltage than model predictions for the power curve.
BETA (Bitter Electromagnet Testing Apparatus)
NASA Astrophysics Data System (ADS)
Bates, Evan M.; Birmingham, William J.; Rivera, William F.; Romero-Talamas, Carlos A.
2017-10-01
The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) prototype of the 10-T Adjustable Long Pulse High-Field Apparatus (ALPHA). These water-cooled resistive magnets use high DC currents to produce strong uniform magnetic fields. Presented here is the successful completion of the BETA project and experimental results validating analytical magnet designing methods developed at the Dusty Plasma Laboratory (DPL). BETA's final design specifications will be highlighted which include electromagnetic, thermal and stress analyses. The magnet core design will be explained which include: Bitter Arcs, helix starters, and clamping annuli. The final version of the magnet's vessel and cooling system are also presented, as well as the electrical system of BETA, which is composed of a unique solid-state breaker circuit. Experimental results presented will show the operation of BETA at 1 T. The results are compared to both analytical design methods and finite element analysis calculations. We also explore the steady state maximums and theoretical limits of BETA's design. The completion of BETA validates the design and manufacturing techniques that will be used in the succeeding magnet, ALPHA.
New technology in turbine aerodynamics
NASA Technical Reports Server (NTRS)
Glassman, A. J.; Moffitt, T. P.
1972-01-01
A cursory review is presented of some of the recent work that has been done in turbine aerodynamic research at NASA-Lewis Research Center. Topics discussed include the aerodynamic effect of turbine coolant, high work-factor (ratio of stage work to square of blade speed) turbines, and computer methods for turbine design and performance prediction. An extensive bibliography is included. Experimental cooled-turbine aerodynamics programs using two-dimensional cascades, full annular cascades, and cold rotating turbine stage tests are discussed with some typical results presented. Analytically predicted results for cooled blade performance are compared to experimental results. The problems and some of the current programs associated with the use of very high work factors for fan-drive turbines of high-bypass-ratio engines are discussed. Turbines currently being investigated make use of advanced blading concepts designed to maintain high efficiency under conditions of high aerodynamic loading. Computer programs have been developed for turbine design-point performance, off-design performance, supersonic blade profile design, and the calculation of channel velocities for subsonic and transonic flow fields. The use of these programs for the design and analysis of axial and radial turbines is discussed.
Aghili, Zahra Sadat; Zarkesh-Esfahani, Sayyed Hamid
2018-02-01
Growth hormone deficiency results in growth retardation in children and the GH deficiency syndrome in adults and they need to receive recombinant-GH in order to rectify the GH deficiency symptoms. Mammalian cells have become the favorite system for production of recombinant proteins for clinical application compared to prokaryotic systems because of their capability for appropriate protein folding, assembly, post-translational modification and proper signal. However, production level in mammalian cells is generally low compared to prokaryotic hosts. Taguchi has established orthogonal arrays to describe a large number of experimental situations mainly to reduce experimental errors and to enhance the efficiency and reproducibility of laboratory experiments.In the present study, rhGH was produced in CHO cells and production of rhGH was assessed using Dot blotting, western blotting and Elisa assay. For optimization of rhGH production in CHO cells using Taguchi method An M16 orthogonal experimental design was used to investigate four different culture components. The biological activity of rhGH was assessed using LHRE-TK-Luciferase reporter gene system in HEK-293 and compared to the biological activity of prokaryotic rhGH.A maximal productivity of rhGH was reached in the conditions of 1%DMSO, 1%glycerol, 25 µM ZnSO 4 and 0 mM NaBu. Our findings indicate that control of culture conditions such as the addition of chemical components helps to develop an efficient large-scale and industrial process for the production of rhGH in CHO cells. Results of bioassay indicated that rhGH produced by CHO cells is able to induce GH-mediated intracellular cell signaling and showed higher bioactivity when compared to prokaryotic GH at the same concentrations. © Georg Thieme Verlag KG Stuttgart · New York.
ERIC Educational Resources Information Center
Lee, Il-Sun; Byeon, Jung-Ho; Kim, Young-shin; Kwon, Yong-Ju
2014-01-01
The purpose of this study was to develop a model for measuring experimental design ability based on functional magnetic resonance imaging (fMRI) during biological inquiry. More specifically, the researchers developed an experimental design task that measures experimental design ability. Using the developed experimental design task, they measured…
TSP Symposium 2013 Proceedings
2014-01-01
test and Post - test Results of the Experimental Group Our results show that the experimental group improved on the post - test compared...4.3.4 Design of the Learning Strategy 27 4.4 Results 28 4.4.1 Post - test 28 4.4.2 Analysis of the Results 28 4.4.3 Analysis of the Results from the...Estimation Accuracy) 17 Figure 5: Methodology for the Research 24 Figure 6: Question 1, Time Control for Post - test 28 Figure 7:
Rodriguez, G Y; Valverde-Ramírez, M; Mendes, C E; Béttega, R; Badino, A C
2015-11-01
Global variables play a key role in evaluation of the performance of pneumatic bioreactors and provide criteria to assist in system selection and design. The purpose of this work was to use experimental data and computational fluid dynamics (CFD) simulations to determine the global performance parameters gas holdup ([Formula: see text]) and volumetric oxygen transfer coefficient (k L a), and conduct an analysis of liquid circulation velocity, for three different geometries of pneumatic bioreactors: bubble column, concentric-tube airlift, and split tube airlift. All the systems had 5 L working volumes and two Newtonian fluids of different viscosities were used in the experiments: distilled water and 10 cP glycerol solution. Considering the high oxygen demand in certain types of aerobic fermentations, the assays were carried out at high flow rates. In the present study, the performances of three pneumatic bioreactors with different geometries and operating with two different Newtonian fluids were compared. A new CFD modeling procedure was implemented, and the simulation results were compared with the experimental data. The findings indicated that the concentric-tube airlift design was the best choice in terms of both gas holdup and volumetric oxygen transfer coefficient. The CFD results for gas holdup were consistent with the experimental data, and indicated that k L a was strongly influenced by bubble diameter and shape.
Kang, Chang-Wei; Wang, Yan; Tania, Marshella; Zhou, Huancheng; Gao, Yi; Ba, Te; Tan, Guo-Dong Sean; Kim, Sangho; Leo, Hwa Liang
2013-01-01
A myriad of bioreactor configurations have been investigated as extracorporeal medical support systems for temporary replacement of vital organ functions. In recent years, studies have demonstrated that the rotating bioreactors have the potential to be utilized as bioartificial liver assist devices (BLADs) owing to their advantage of ease of scalability of cell-culture volume. However, the fluid movement in the rotating chamber will expose the suspended cells to unwanted flow structures with abnormally high shear conditions that may result in poor cell stability and in turn lower the efficacy of the bioreactor system. In this study, we compared the hydrodynamic performance of our modified rotating bioreactor design with that of an existing rotating bioreactor design. Computational fluid dynamic analysis coupled with experimental results were employed in the optimization process for the development of the modified bioreactor design. Our simulation results showed that the modified bioreactor had lower fluid induced shear stresses and more uniform flow conditions within its rotating chamber than the conventional design. Experimental results revealed that the cells within the modified bioreactor also exhibited better cell-carrier attachment, higher metabolic activity, and cell viability compared to those in the conventional design. In conclusion, this study was able to provide important insights into the flow physics within the rotating bioreactors, and help enhanced the hydrodynamic performance of an existing rotating bioreactor for BLAD applications. © 2013 American Institute of Chemical Engineers.
Knowledge Synthesis with Maps of Neural Connectivity
Tallis, Marcelo; Thompson, Richard; Russ, Thomas A.; Burns, Gully A. P. C.
2011-01-01
This paper describes software for neuroanatomical knowledge synthesis based on neural connectivity data. This software supports a mature methodology developed since the early 1990s. Over this time, the Swanson laboratory at USC has generated an account of the neural connectivity of the sub-structures of the hypothalamus, amygdala, septum, hippocampus, and bed nucleus of the stria terminalis. This is based on neuroanatomical data maps drawn into a standard brain atlas by experts. In earlier work, we presented an application for visualizing and comparing anatomical macro connections using the Swanson third edition atlas as a framework for accurate registration. Here we describe major improvements to the NeuARt application based on the incorporation of a knowledge representation of experimental design. We also present improvements in the interface and features of the data mapping components within a unified web-application. As a step toward developing an accurate sub-regional account of neural connectivity, we provide navigational access between the data maps and a semantic representation of area-to-area connections that they support. We do so based on an approach called “Knowledge Engineering from Experimental Design” (KEfED) model that is based on experimental variables. We have extended the underlying KEfED representation of tract-tracing experiments by incorporating the definition of a neuronanatomical data map as a measurement variable in the study design. This paper describes the software design of a web-application that allows anatomical data sets to be described within a standard experimental context and thus indexed by non-spatial experimental design features. PMID:22053155
Consideration of Wear Rates at High Velocity
2010-03-01
specimen retracted back into the test slipper. The amount of wear was analyzed by comparing the pretest and posttest specimen thicknesses and weights...and Design System (DADS) Model . . . . . . . . . . . . . . . . . . . . . . . 62 3.1.2 January 2008 Test Mission Raw DADS Data . . 64 3.1.3 DADS...The experimental high-speed test track at Holloman Air Force Base (AFB) has undergone many design innovations over a span of fifty years. One of the
Camel Gate Field Effect Transistors.
1983-01-01
CAMFETs can be designed to yield relatively voltage independent transconductances, large for- * ward turn-on voltages, and large gate-drain breakdown...doping. The FATFET area is 4.6 x 10- 4 cm2. I.- . - . . - , - 36 80 * Camel Gate U_-- Eperimental 60 * -Theoretical % Schottky Gate ~--Experimental CL 4...in the design of other devices. Finally, a comparative study of the reliabil- ities of CAMFETs, JFETs, and MESFETs should be attempted. 43 VII
Roopa Rani, M; Rudramoorthy, R
2013-03-01
Ultrasonic horns are tuned components designed to vibrate in a longitudinal mode at ultrasonic frequencies. Reliable performance of such horns is normally decided by the uniformity of vibration amplitude at the working surface and the stress developed during loading condition. The horn design engineer must pay particular attention to designing a tool that will produce the desired amplitude without fracturing. The present work discusses horn configurations which satisfy these criteria and investigates the design requirements of horns in ultrasonic system. Different horn profiles for ultrasonic welding of thermoplastics have been characterized in terms of displacement amplitude and von-Mises stresses using modal and harmonic analysis. To validate the simulated results, five different horns are fabricated from Aluminum, tested and tuned to the operating frequency. Standard ABS plastic parts are welded using these horns. Temperature developed during the welding of ABS test parts using different horns is recorded using sensors and National Instruments (NIs) data acquisition system. The recorded values are compared with the predicted values. Experimental results show that welding using a Bezier horn has a high interface temperature and the welded joints had higher strength as compared to the other horn profiles. Copyright © 2012 Elsevier B.V. All rights reserved.
A comparative analysis of speed profile models for wrist pointing movements.
Vaisman, Lev; Dipietro, Laura; Krebs, Hermano Igo
2013-09-01
Following two decades of design and clinical research on robot-mediated therapy for the shoulder and elbow, therapeutic robotic devices for other joints are being proposed: several research groups including ours have designed robots for the wrist, either to be used as stand-alone devices or in conjunction with shoulder and elbow devices. However, in contrast with robots for the shoulder and elbow which were able to take advantage of descriptive kinematic models developed in neuroscience for the past 30 years, design of wrist robots controllers cannot rely on similar prior art: wrist movement kinematics has been largely unexplored. This study aimed at examining speed profiles of fast, visually evoked, visually guided, target-directed human wrist pointing movements. One thousand three-hundred ninety-eight (1398) trials were recorded from seven unimpaired subjects who performed center-out flexion/extension and abduction/adduction wrist movements and fitted with 19 models previously proposed for describing reaching speed profiles. A nonlinear, least squares optimization procedure extracted parameters' sets that minimized error between experimental and reconstructed data. Models' performances were compared based on their ability to reconstruct experimental data. Results suggest that the support-bounded lognormal is the best model for speed profiles of fast, wrist pointing movements. Applications include design of control algorithms for therapeutic wrist robots and quantitative metrics of motor recovery.
NASA Astrophysics Data System (ADS)
Marudhappan, Raja; Chandrasekhar, Udayagiri; Hemachandra Reddy, Koni
2017-10-01
The design of plain orifice simplex atomizer for use in the annular combustion system of 1100 kW turbo shaft engine is optimized. The discrete flow field of jet fuel inside the swirl chamber of the atomizer and up to 1.0 mm downstream of the atomizer exit are simulated using commercial Computational Fluid Dynamics (CFD) software. The Euler-Euler multiphase model is used to solve two sets of momentum equations for liquid and gaseous phases and the volume fraction of each phase is tracked throughout the computational domain. The atomizer design is optimized after performing several 2D axis symmetric analyses with swirl and the optimized inlet port design parameters are used for 3D simulation. The Volume Of Fluid (VOF) multiphase model is used in the simulation. The orifice exit diameter is 0.6 mm. The atomizer is fabricated with the optimized geometric parameters. The performance of the atomizer is tested in the laboratory. The experimental observations are compared with the results obtained from 2D and 3D CFD simulations. The simulated velocity components, pressure field, streamlines and air core dynamics along the atomizer axis are compared to previous research works and found satisfactory. The work has led to a novel approach in the design of pressure swirl atomizer.
Matha, Denis; Sandner, Frank; Molins, Climent; Campos, Alexis; Cheng, Po Wen
2015-02-28
The current key challenge in the floating offshore wind turbine industry and research is on designing economic floating systems that can compete with fixed-bottom offshore turbines in terms of levelized cost of energy. The preliminary platform design, as well as early experimental design assessments, are critical elements in the overall design process. In this contribution, a brief review of current floating offshore wind turbine platform pre-design and scaled testing methodologies is provided, with a focus on their ability to accommodate the coupled dynamic behaviour of floating offshore wind systems. The exemplary design and testing methodology for a monolithic concrete spar platform as performed within the European KIC AFOSP project is presented. Results from the experimental tests compared to numerical simulations are presented and analysed and show very good agreement for relevant basic dynamic platform properties. Extreme and fatigue loads and cost analysis of the AFOSP system confirm the viability of the presented design process. In summary, the exemplary application of the reduced design and testing methodology for AFOSP confirms that it represents a viable procedure during pre-design of floating offshore wind turbine platforms. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
NASA Technical Reports Server (NTRS)
Roozeboom, Nettie H.; Lee, Henry C.; Simurda, Laura J.; Zilliac, Gregory G.; Pulliam, Thomas H.
2016-01-01
Wing-body juncture flow fields on commercial aircraft configurations are challenging to compute accurately. The NASA Advanced Air Vehicle Program's juncture flow committee is designing an experiment to provide data to improve Computational Fluid Dynamics (CFD) modeling in the juncture flow region. Preliminary design of the model was done using CFD, yet CFD tends to over-predict the separation in the juncture flow region. Risk reduction wind tunnel tests were requisitioned by the committee to obtain a better understanding of the flow characteristics of the designed models. NASA Ames Research Center's Fluid Mechanics Lab performed one of the risk reduction tests. The results of one case, accompanied by CFD simulations, are presented in this paper. Experimental results suggest the wall mounted wind tunnel model produces a thicker boundary layer on the fuselage than the CFD predictions, resulting in a larger wing horseshoe vortex suppressing the side of body separation in the juncture flow region. Compared to experimental results, CFD predicts a thinner boundary layer on the fuselage generates a weaker wing horseshoe vortex resulting in a larger side of body separation.
Design of a microfluidic system for red blood cell aggregation investigation.
Mehri, R; Mavriplis, C; Fenech, M
2014-06-01
The purpose of this paper is to design a microfluidic apparatus capable of providing controlled flow conditions suitable for red blood cell (RBC) aggregation analysis. The linear velocity engendered from the controlled flow provides constant shear rates used to qualitatively analyze RBC aggregates. The design of the apparatus is based on numerical and experimental work. The numerical work consists of 3D numerical simulations performed using a research computational fluid dynamics (CFD) solver, Nek5000, while the experiments are conducted using a microparticle image velocimetry system. A Newtonian model is tested numerically and experimentally, then blood is tested experimentally under several conditions (hematocrit, shear rate, and fluid suspension) to be compared to the simulation results. We find that using a velocity ratio of 4 between the two Newtonian fluids, the layer corresponding to blood expands to fill 35% of the channel thickness where the constant shear rate is achieved. For blood experiments, the velocity profile in the blood layer is approximately linear, resulting in the desired controlled conditions for the study of RBC aggregation under several flow scenarios.
An Experimental Design of Bypass Magneto-Rheological (MR) damper
NASA Astrophysics Data System (ADS)
Rashid, MM; Aziz, Mohammad Abdul; Raisuddin Khan, Md.
2017-11-01
The magnetorheological (MR) fluid bypass damper fluid flow through a bypass by utilizing an external channel which allows the controllability of MR fluid in the channel. The Bypass MR damper (BMRD) contains a rectangular bypass flow channel, current controlled movable piston shaft arrangement and MR fluid. The static piston coil case is winding by a coil which is used inside the piston head arrangement. The current controlled coil case provides a magnetic flux through the BMRD cylinder for controllability. The high strength of alloy steel materials are used for making piston shaft which allows magnetic flux propagation throughout the BMRD cylinder. Using the above design materials, a Bypass MR damper is designed and tested. An excitation of current is applied during the experiment which characterizes the BMRD controllability. It is shown that the BMRD with external flow channel allows a high controllable damping force using an excitation current. The experimental result of damping force-displacement characteristics with current excitation and without current excitation are compared in this research. The BMRD model is validated by the experimental result at various frequencies and applied excitation current.
Comparing the efficiency of supersonic oxygen-iodine laser with different mixing designs
NASA Astrophysics Data System (ADS)
Vyskubenko, Boris A.; Adamenkov, A. A.; Bakshin, V. V.; Efremov, V. I.; Ilyin, S. P.; Kolobyanin, Yu. V.; Krukovsky, I. M.; Kudryashov, E. A.; Moiseyev, V. B.
2003-11-01
The paper presents experimental studies of supersonic oxygen-iodine laser (OIL) using twisted-flow singlet oxygen generator (SOG) over a wide range of the singlet oxygen pressures and the buffer gas flow rates. The experiments used different designs of the nozzle unit and mixing system for singlet oxygen and iodine gas with the carrier gas (such as nitrogen or helium). For a wide range of the key parameters, the study looked at the efficiency of supersonic OIL with variation of the singlet oxygen pressure. The measurements were made for different positions of the iodine injection plane with respect to the critical cross-section (both in the subsonic part of the nozzle and in the supersonic flow). The gas pressure at the nozzle unit entry was varied from 50 to 250 Torr. The total pressure loss have been found for different mixing designs. Experimental curves are given for energy performance and chemical efficiency of the supersonic OIL as a function of the key parameters. Comparison is made between the calculated and experimental data. For the optimum conditions of OIL operation, chemical efficiency of 25-30% has been achieved.
Performance of lap splices in large-scale column specimens affected by ASR and/or DEF.
DOT National Transportation Integrated Search
2012-06-01
This research program conducted a large experimental program, which consisted of the design, construction, : curing, deterioration, and structural load testing of 16 large-scale column specimens with a critical lap splice : region, and then compared ...
Exploring Chaos: A Case Study.
ERIC Educational Resources Information Center
Nemirovsky, Ricardo; Tinker, Robert
1993-01-01
Describes software, hardware, and devices that were designed to provide students with an environment to experiment with basic ideas of mechanics, including nonlinear dynamics. Examines the behavior of a Lorenzian water wheel by comparing experimental data with theoretical results obtained from computer-based sensors. (MDH)
Maternal Voice and Short-Term Outcomes in Preterm Infants
Krueger, Charlene; Parker, Leslie; Chiu, Sheau-Huey; Theriaque, Douglas
2013-01-01
This study explored effects of exposure to maternal voice on short-term outcomes in very low birth weight preterm infants cared for within an neonatal intensive care unit (NICU) without an ongoing program of developmental care. Using a comparative design, 53 infants born during their 27th to 28th postmenstrual week were sampled by convenience. Experimental groups were exposed to maternal voice during two developmental time periods. Group 1 listened to a recording of their mothers reciting a rhyme from 28 to 34 postmenstrual weeks. Group 2 waited 4 weeks and heard the recording from 32 to 34 weeks. The control group received routine care. The primary analysis of combined experimental groups compared to the control group revealed that the experimental infants experienced significantly fewer episodes of feeding intolerance and achieved full enteral feeds quicker compared to the control group. Further, in an analysis evaluating all three groups separately, it was noted that Group 1 experienced significantly fewer episodes of feeding intolerance compared to the control group. Study findings warrant further investigation of exposure to maternal voice and the developmental timing at which exposure is begun. PMID:20112262
Design of clinical trials involving multiple hypothesis tests with a common control.
Schou, I Manjula; Marschner, Ian C
2017-07-01
Randomized clinical trials comparing several treatments to a common control are often reported in the medical literature. For example, multiple experimental treatments may be compared with placebo, or in combination therapy trials, a combination therapy may be compared with each of its constituent monotherapies. Such trials are typically designed using a balanced approach in which equal numbers of individuals are randomized to each arm, however, this can result in an inefficient use of resources. We provide a unified framework and new theoretical results for optimal design of such single-control multiple-comparator studies. We consider variance optimal designs based on D-, A-, and E-optimality criteria, using a general model that allows for heteroscedasticity and a range of effect measures that include both continuous and binary outcomes. We demonstrate the sensitivity of these designs to the type of optimality criterion by showing that the optimal allocation ratios are systematically ordered according to the optimality criterion. Given this sensitivity to the optimality criterion, we argue that power optimality is a more suitable approach when designing clinical trials where testing is the objective. Weighted variance optimal designs are also discussed, which, like power optimal designs, allow the treatment difference to play a major role in determining allocation ratios. We illustrate our methods using two real clinical trial examples taken from the medical literature. Some recommendations on the use of optimal designs in single-control multiple-comparator trials are also provided. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bayesian Dose-Response Modeling in Sparse Data
NASA Astrophysics Data System (ADS)
Kim, Steven B.
This book discusses Bayesian dose-response modeling in small samples applied to two different settings. The first setting is early phase clinical trials, and the second setting is toxicology studies in cancer risk assessment. In early phase clinical trials, experimental units are humans who are actual patients. Prior to a clinical trial, opinions from multiple subject area experts are generally more informative than the opinion of a single expert, but we may face a dilemma when they have disagreeing prior opinions. In this regard, we consider compromising the disagreement and compare two different approaches for making a decision. In addition to combining multiple opinions, we also address balancing two levels of ethics in early phase clinical trials. The first level is individual-level ethics which reflects the perspective of trial participants. The second level is population-level ethics which reflects the perspective of future patients. We extensively compare two existing statistical methods which focus on each perspective and propose a new method which balances the two conflicting perspectives. In toxicology studies, experimental units are living animals. Here we focus on a potential non-monotonic dose-response relationship which is known as hormesis. Briefly, hormesis is a phenomenon which can be characterized by a beneficial effect at low doses and a harmful effect at high doses. In cancer risk assessments, the estimation of a parameter, which is known as a benchmark dose, can be highly sensitive to a class of assumptions, monotonicity or hormesis. In this regard, we propose a robust approach which considers both monotonicity and hormesis as a possibility. In addition, We discuss statistical hypothesis testing for hormesis and consider various experimental designs for detecting hormesis based on Bayesian decision theory. Past experiments have not been optimally designed for testing for hormesis, and some Bayesian optimal designs may not be optimal under a wrong parametric assumption. In this regard, we consider a robust experimental design which does not require any parametric assumption.
NASA Astrophysics Data System (ADS)
Reeves, Carolyn T.
This research attempted to test the effectiveness of strategies designed for teaching the nature of science to Biology I students and to examine the effects of frequency of use of the strategies. Some strategies were designed to identify misconceptions about the nature of science; others were designed to correct misconceptions or provide correct concepts about the nature of science. This research commenced during the 3rd week of the 2001--2002 school year after obtaining IRB approval and permissions from school officials. The study ended after the 15th week. All participating students were given a pretest and a posttest of the Nature of Scientific Knowledge Scale Enhanced (NSKSE) test. Part I, 48 items, consisted of the NSKS test by Rubba & Anderson (1978). Part II, 10 items, consisted of a test constructed by the researcher. Part I contained questions about 6 tenets of the nature of science. Part II contained questions about how science works. The strategies were tested in two Biology I experimental classes, n = 41, and compared with two Biology I control classes, n = 34, by means of an analysis of covariance with the pretest scores used as the covariate. The overall mean posttest scores of the experimental and the control group were not found to be significantly different on either Part I, F(1,72) = 1.059, p = .307, or Part II, F(1,72) = 3.136, p = .081, of the test instrument. The number of times a strategy was used in each experimental classroom was determined. It was found that strategies were used almost twice as often in one classroom than in the other. A second set of ANCOVA analyses compared mean scores between Experimental Class A, Experimental Class B, and the control group. There was no significant difference between the groups on Part I, F(2,71) = .921, p = .403, but the difference between groups on Part II, F(2,71) = 5.769, p = .005, was significant. A post hoc Scheffe analysis showed that the class using strategies most often differed significantly with the control group, p = .009, but the other class did not, p = .929. This study suggests that frequent use of the designed strategies was effective in helping Biology I students understand some aspects of the nature of science. It also suggests that minimal use of the strategies was not effective.
Design of a family of ring-core fibers for OAM transmission studies.
Brunet, Charles; Ung, Bora; Wang, Lixian; Messaddeq, Younès; LaRochelle, Sophie; Rusch, Leslie A
2015-04-20
We propose a family of ring-core fibers, designed for the transmission of OAM modes, that can be fabricated by drawing five different fibers from a single preform. This novel technique allows us to experimentally sweep design parameters and speed up the fiber design optimization process. Such a family of fibers could be used to examine system performance, but also facilitate understanding of parameter impact in the transition from design to fabrication. We present design parameters characterizing our fiber, and enumerate criteria to be satisfied. We determine targeted fiber dimensions and explain our strategy for examining a design family rather than a single fiber design. We simulate modal properties of the designed fibers, and compare the results with measurements performed on fabricated fibers.
Selecting promising treatments in randomized Phase II cancer trials with an active control.
Cheung, Ying Kuen
2009-01-01
The primary objective of Phase II cancer trials is to evaluate the potential efficacy of a new regimen in terms of its antitumor activity in a given type of cancer. Due to advances in oncology therapeutics and heterogeneity in the patient population, such evaluation can be interpreted objectively only in the presence of a prospective control group of an active standard treatment. This paper deals with the design problem of Phase II selection trials in which several experimental regimens are compared to an active control, with an objective to identify an experimental arm that is more effective than the control or to declare futility if no such treatment exists. Conducting a multi-arm randomized selection trial is a useful strategy to prioritize experimental treatments for further testing when many candidates are available, but the sample size required in such a trial with an active control could raise feasibility concerns. In this study, we extend the sequential probability ratio test for normal observations to the multi-arm selection setting. The proposed methods, allowing frequent interim monitoring, offer high likelihood of early trial termination, and as such enhance enrollment feasibility. The termination and selection criteria have closed form solutions and are easy to compute with respect to any given set of error constraints. The proposed methods are applied to design a selection trial in which combinations of sorafenib and erlotinib are compared to a control group in patients with non-small-cell lung cancer using a continuous endpoint of change in tumor size. The operating characteristics of the proposed methods are compared to that of a single-stage design via simulations: The sample size requirement is reduced substantially and is feasible at an early stage of drug development.
EXPERIMENTAL MODELLING OF AORTIC ANEURYSMS
Doyle, Barry J; Corbett, Timothy J; Cloonan, Aidan J; O’Donnell, Michael R; Walsh, Michael T; Vorp, David A; McGloughlin, Timothy M
2009-01-01
A range of silicone rubbers were created based on existing commercially available materials. These silicones were designed to be visually different from one another and have distinct material properties, in particular, ultimate tensile strengths and tear strengths. In total, eleven silicone rubbers were manufactured, with the materials designed to have a range of increasing tensile strengths from approximately 2-4MPa, and increasing tear strengths from approximately 0.45-0.7N/mm. The variations in silicones were detected using a standard colour analysis technique. Calibration curves were then created relating colour intensity to individual material properties. All eleven materials were characterised and a 1st order Ogden strain energy function applied. Material coefficients were determined and examined for effectiveness. Six idealised abdominal aortic aneurysm models were also created using the two base materials of the study, with a further model created using a new mixing technique to create a rubber model with randomly assigned material properties. These models were then examined using videoextensometry and compared to numerical results. Colour analysis revealed a statistically significant linear relationship (p<0.0009) with both tensile strength and tear strength, allowing material strength to be determined using a non-destructive experimental technique. The effectiveness of this technique was assessed by comparing predicted material properties to experimentally measured methods, with good agreement in the results. Videoextensometry and numerical modelling revealed minor percentage differences, with all results achieving significance (p<0.0009). This study has successfully designed and developed a range of silicone rubbers that have unique colour intensities and material strengths. Strengths can be readily determined using a non-destructive analysis technique with proven effectiveness. These silicones may further aid towards an improved understanding of the biomechanical behaviour of aneurysms using experimental techniques. PMID:19595622
Thermochemical Modeling of Nonequilibrium Oxygen Flows
NASA Astrophysics Data System (ADS)
Neitzel, Kevin Joseph
The development of hypersonic vehicles leans heavily on computational simulation due to the high enthalpy flow conditions that are expensive and technically challenging to replicate experimentally. The accuracy of the nonequilibrium modeling in the computer simulations dictates the design margin that is required for the thermal protection system and flight dynamics. Previous hypersonic vehicles, such as Apollo and the Space Shuttle, were primarily concerned with re-entry TPS design. The strong flow conditions of re-entry, involving Mach numbers of 25, quickly dissociate the oxygen molecules in air. Sustained flight, hypersonic vehicles will be designed to operate in Mach number ranges of 5 to 10. The oxygen molecules will not quickly dissociate and will play an important role in the flow field behavior. The development of nonequilibrium models of oxygen is crucial for limiting modeling uncertainty. Thermochemical nonequilibrium modeling is investigated for oxygen flows. Specifically, the vibrational relaxation and dissociation behavior that dominate the nonequilibrium physics in this flight regime are studied in detail. The widely used two-temperature (2T) approach is compared to the higher fidelity and more computationally expensive state-to-state (STS) approach. This dissertation utilizes a wide range of rate sources, including newly available STS rates, to conduct a comprehensive study of modeling approaches for hypersonic nonequilibrium thermochemical modeling. Additionally, the physical accuracy of the computational methods are assessed by comparing the numerical results with available experimental data. The numerical results and experimental measurements present strong nonequilibrium, and even non-Boltzmann behavior in the vibrational energy mode for the sustained hypersonic flight regime. The STS approach is able to better capture the behavior observed in the experimental data, especially for stronger nonequilibrium conditions. Additionally, a reduced order model (ROM) modification to the 2T model is developed to improve the capability of the 2T approach framework.
Van Derlinden, E; Bernaerts, K; Van Impe, J F
2010-05-21
Optimal experiment design for parameter estimation (OED/PE) has become a popular tool for efficient and accurate estimation of kinetic model parameters. When the kinetic model under study encloses multiple parameters, different optimization strategies can be constructed. The most straightforward approach is to estimate all parameters simultaneously from one optimal experiment (single OED/PE strategy). However, due to the complexity of the optimization problem or the stringent limitations on the system's dynamics, the experimental information can be limited and parameter estimation convergence problems can arise. As an alternative, we propose to reduce the optimization problem to a series of two-parameter estimation problems, i.e., an optimal experiment is designed for a combination of two parameters while presuming the other parameters known. Two different approaches can be followed: (i) all two-parameter optimal experiments are designed based on identical initial parameter estimates and parameters are estimated simultaneously from all resulting experimental data (global OED/PE strategy), and (ii) optimal experiments are calculated and implemented sequentially whereby the parameter values are updated intermediately (sequential OED/PE strategy). This work exploits OED/PE for the identification of the Cardinal Temperature Model with Inflection (CTMI) (Rosso et al., 1993). This kinetic model describes the effect of temperature on the microbial growth rate and encloses four parameters. The three OED/PE strategies are considered and the impact of the OED/PE design strategy on the accuracy of the CTMI parameter estimation is evaluated. Based on a simulation study, it is observed that the parameter values derived from the sequential approach deviate more from the true parameters than the single and global strategy estimates. The single and global OED/PE strategies are further compared based on experimental data obtained from design implementation in a bioreactor. Comparable estimates are obtained, but global OED/PE estimates are, in general, more accurate and reliable. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Federal Trade Commission, Washington, DC. Bureau of Consumer Protection.
A non-experimental design was used to determine if scores of students enrolled in specified major coaching schools were significantly higher than scores of comparable uncoached groups. Score increases at two Scholastic Aptitude Test (SAT) coaching schools and Law School Admission Test (LSAT) schools were compared. Over 1,400 SAT examinees and…
ERIC Educational Resources Information Center
Simonsen, Brandi; Myers, Diane; Briere, Donald E., III
2011-01-01
Students who continue to demonstrate at-risk behaviors after a school implements schoolwide primary (Tier 1) interventions require targeted-group secondary (Tier 2) interventions. This study was conducted to compare the effectiveness of a targeted-group behavioral check-in/check-out (CICO) intervention with the school's standard practice (SP) with…
ERIC Educational Resources Information Center
Yang, Nancy Kueifen; Schaller, James L.; Huang, Tzu-Ai; Wang, Meei Huey; Tsai, Shu-Fei
2003-01-01
This study compares generalized effects of a social-emotional skills training for girls and boys with autism in resource rooms on promoting positive social behaviors in general education classrooms in Taiwan. A single subject design was used to compare outcomes for 2 girls and 2 boys with autism in the experimental group with 2 boys with autism in…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilkey, Lindsay
This milestone presents a demonstration of the High-to-Low (Hi2Lo) process in the VVI focus area. Validation and additional calculations with the commercial computational fluid dynamics code, STAR-CCM+, were performed using a 5x5 fuel assembly with non-mixing geometry and spacer grids. This geometry was based on the benchmark experiment provided by Westinghouse. Results from the simulations were compared to existing experimental data and to the subchannel thermal-hydraulics code COBRA-TF (CTF). An uncertainty quantification (UQ) process was developed for the STAR-CCM+ model and results of the STAR UQ were communicated to CTF. Results from STAR-CCM+ simulations were used as experimental design pointsmore » in CTF to calibrate the mixing parameter β and compared to results obtained using experimental data points. This demonstrated that CTF’s β parameter can be calibrated to match existing experimental data more closely. The Hi2Lo process for the STAR-CCM+/CTF code coupling was documented in this milestone and closely linked L3:VVI.H2LP15.01 milestone report.« less
linkedISA: semantic representation of ISA-Tab experimental metadata.
González-Beltrán, Alejandra; Maguire, Eamonn; Sansone, Susanna-Assunta; Rocca-Serra, Philippe
2014-01-01
Reporting and sharing experimental metadata- such as the experimental design, characteristics of the samples, and procedures applied, along with the analysis results, in a standardised manner ensures that datasets are comprehensible and, in principle, reproducible, comparable and reusable. Furthermore, sharing datasets in formats designed for consumption by humans and machines will also maximize their use. The Investigation/Study/Assay (ISA) open source metadata tracking framework facilitates standards-compliant collection, curation, visualization, storage and sharing of datasets, leveraging on other platforms to enable analysis and publication. The ISA software suite includes several components used in increasingly diverse set of life science and biomedical domains; it is underpinned by a general-purpose format, ISA-Tab, and conversions exist into formats required by public repositories. While ISA-Tab works well mainly as a human readable format, we have also implemented a linked data approach to semantically define the ISA-Tab syntax. We present a semantic web representation of the ISA-Tab syntax that complements ISA-Tab's syntactic interoperability with semantic interoperability. We introduce the linkedISA conversion tool from ISA-Tab to the Resource Description Framework (RDF), supporting mappings from the ISA syntax to multiple community-defined, open ontologies and capitalising on user-provided ontology annotations in the experimental metadata. We describe insights of the implementation and how annotations can be expanded driven by the metadata. We applied the conversion tool as part of Bio-GraphIIn, a web-based application supporting integration of the semantically-rich experimental descriptions. Designed in a user-friendly manner, the Bio-GraphIIn interface hides most of the complexities to the users, exposing a familiar tabular view of the experimental description to allow seamless interaction with the RDF representation, and visualising descriptors to drive the query over the semantic representation of the experimental design. In addition, we defined queries over the linkedISA RDF representation and demonstrated its use over the linkedISA conversion of datasets from Nature' Scientific Data online publication. Our linked data approach has allowed us to: 1) make the ISA-Tab semantics explicit and machine-processable, 2) exploit the existing ontology-based annotations in the ISA-Tab experimental descriptions, 3) augment the ISA-Tab syntax with new descriptive elements, 4) visualise and query elements related to the experimental design. Reasoning over ISA-Tab metadata and associated data will facilitate data integration and knowledge discovery.
Physical and Emotional Benefits of Different Exercise Environments Designed for Treadmill Running
Churchill, Sarah M.; Brymer, Eric; Davids, Keith
2017-01-01
(1) Background: Green physical activity promotes physical health and mental wellbeing and interesting questions concern effects of this information on designing indoor exercise environments. This study examined the physical and emotional effects of different nature-based environments designed for indoor treadmill running; (2) Methods: In a counterbalanced experimental design, 30 participants performed three, twenty-minute treadmill runs at a self-selected pace while viewing either a static nature image, a dynamic nature image or self-selected entertainment. Distance ran, heart rate (HR) and five pre-and post-exercise emotional states were measured; (3) Results: Participants ran farther, and with higher HRs, with self-selected entertainment compared to the two nature-based environment designs. Participants attained lowered anger, dejection, anxiety and increased excitement post exercise in all of the designed environments. Happiness increased during the two nature-based environment designs compared with self-selected entertainment; (4) Conclusions: Self-selected entertainment encouraged greater physical performances whereas running in nature-based exercise environments elicited greater happiness immediately after running. PMID:28696384
Physical and Emotional Benefits of Different Exercise Environments Designed for Treadmill Running.
Yeh, Hsiao-Pu; Stone, Joseph A; Churchill, Sarah M; Brymer, Eric; Davids, Keith
2017-07-11
(1) Background: Green physical activity promotes physical health and mental wellbeing and interesting questions concern effects of this information on designing indoor exercise environments. This study examined the physical and emotional effects of different nature-based environments designed for indoor treadmill running; (2) Methods: In a counterbalanced experimental design, 30 participants performed three, twenty-minute treadmill runs at a self-selected pace while viewing either a static nature image, a dynamic nature image or self-selected entertainment. Distance ran, heart rate (HR) and five pre-and post-exercise emotional states were measured; (3) Results: Participants ran farther, and with higher HRs, with self-selected entertainment compared to the two nature-based environment designs. Participants attained lowered anger, dejection, anxiety and increased excitement post exercise in all of the designed environments. Happiness increased during the two nature-based environment designs compared with self-selected entertainment; (4) Conclusions: Self-selected entertainment encouraged greater physical performances whereas running in nature-based exercise environments elicited greater happiness immediately after running.
Experimental Study on Oil Displacement Mechanism
NASA Astrophysics Data System (ADS)
Pi, Yanfu; Shao, Hongzhi; Pi, Yanming; Liu, Li
2018-02-01
In this work, the objective is enhancing oil recovery in offshore heavy oil after polymer flooding. The heterogeneous physical model is especially designed for oil fields with heavy oil. The comparative study of the two displacement experiments was carried out, and the experimental data was compared and analysed. The comparison between scheme one and scheme two was analysed from the production curve. The patterns of cores are analysed and compared with each other. It was found that the oil in the high permeability layer and medium permeability layer had been widely removed in the stage of binary combination flooding. There was a high degree of use in the low permeability layer. The recovery ratio is 66.29%. After polymer flooding, the addition of binary combination flooding in the heavy oil reservoir can greatly enhance oil recovery.
Modular disposable can (MODCAN) crash cushion: A concept investigation
NASA Technical Reports Server (NTRS)
Knoell, A.; Wilson, A.
1976-01-01
A conceptual design investigation of an improved highway crash cushion system is presented. The system is referred to as a modular disposable can (MODCAN) crash system. It is composed of a modular arrangement of disposable metal beverage cans configured to serve as an effective highway impact attenuation system. Experimental data, design considerations, and engineering calculations supporting the design development are presented. Design performance is compared to that of a conventional steel drum system. It is shown that the MODCAN concepts offers the potential for smoother and safer occupant deceleration for a larger class of vehicle impact weights than the steel drum device.
Experimental verification of Space Platform battery discharger design optimization
NASA Astrophysics Data System (ADS)
Sable, Dan M.; Deuty, Scott; Lee, Fred C.; Cho, Bo H.
The detailed design of two candidate topologies for the Space Platform battery discharger, a four module boost converter (FMBC) and a voltage-fed push-pull autotransformer (VFPPAT), is presented. Each has unique problems. The FMBC requires careful design and analysis in order to obtain good dynamic performance. This is due to the presence of a right-half-plane (RHP) zero in the control-to-output transfer function. The VFPPAT presents a challenging power stage design in order to yield high efficiency and light component weight. The authors describe the design of each of these converters and compare their efficiency, weight, and dynamic characteristics.
Ryeznik, Yevgen; Sverdlov, Oleksandr; Wong, Weng Kee
2015-08-01
Response-adaptive randomization designs are becoming increasingly popular in clinical trial practice. In this paper, we present RARtool , a user interface software developed in MATLAB for designing response-adaptive randomized comparative clinical trials with censored time-to-event outcomes. The RARtool software can compute different types of optimal treatment allocation designs, and it can simulate response-adaptive randomization procedures targeting selected optimal allocations. Through simulations, an investigator can assess design characteristics under a variety of experimental scenarios and select the best procedure for practical implementation. We illustrate the utility of our RARtool software by redesigning a survival trial from the literature.
Experimental verification of Space Platform battery discharger design optimization
NASA Technical Reports Server (NTRS)
Sable, Dan M.; Deuty, Scott; Lee, Fred C.; Cho, Bo H.
1991-01-01
The detailed design of two candidate topologies for the Space Platform battery discharger, a four module boost converter (FMBC) and a voltage-fed push-pull autotransformer (VFPPAT), is presented. Each has unique problems. The FMBC requires careful design and analysis in order to obtain good dynamic performance. This is due to the presence of a right-half-plane (RHP) zero in the control-to-output transfer function. The VFPPAT presents a challenging power stage design in order to yield high efficiency and light component weight. The authors describe the design of each of these converters and compare their efficiency, weight, and dynamic characteristics.
Active controls: A look at analytical methods and associated tools
NASA Technical Reports Server (NTRS)
Newsom, J. R.; Adams, W. M., Jr.; Mukhopadhyay, V.; Tiffany, S. H.; Abel, I.
1984-01-01
A review of analytical methods and associated tools for active controls analysis and design problems is presented. Approaches employed to develop mathematical models suitable for control system analysis and/or design are discussed. Significant efforts have been expended to develop tools to generate the models from the standpoint of control system designers' needs and develop the tools necessary to analyze and design active control systems. Representative examples of these tools are discussed. Examples where results from the methods and tools have been compared with experimental data are also presented. Finally, a perspective on future trends in analysis and design methods is presented.
A More Rigorous Quasi-Experimental Alternative to the One-Group Pretest-Posttest Design.
ERIC Educational Resources Information Center
Johnson, Craig W.
1986-01-01
A simple quasi-experimental design is described which may have utility in a variety of applied and laboratory research settings where ordinarily the one-group pretest-posttest pre-experimental design might otherwise be the procedure of choice. The design approaches the internal validity of true experimental designs while optimizing external…
USDA-ARS?s Scientific Manuscript database
Lariat is a high-oleic runner-type peanut (Arachis hypogaea L. subsp. hypogaea var. hypogaea) that has enhanced Sclerotinia blight and pod rot tolerance when compared to the cultivar Red River Runner. Lariat (experimental designation ARSOK-R35) is the result of a cross between cultivar Red River Ru...
Registration of 'Lariat' peanut
USDA-ARS?s Scientific Manuscript database
'Lariat' is a high-oleic runner-type peanut (Arachis hypogaea L. subsp. hypogaea var. hypogaea) that has enhanced Sclerotinia blight and pod rot tolerance when compared to the cultivar Red River Runner. 'Lariat' (experimental designation ARSOK-R35) is the result of a cross between cultivar Red Rive...
Graders' Mathematics Achievement
ERIC Educational Resources Information Center
Bond, John B.; Ellis, Arthur K.
2013-01-01
The purpose of this experimental study was to investigate the effects of metacognitive reflective assessment instruction on student achievement in mathematics. The study compared the performance of 141 students who practiced reflective assessment strategies with students who did not. A posttest-only control group design was employed, and results…
Influencing Educational Practice through Performance Indicators.
ERIC Educational Resources Information Center
Tymms, P. B.
1995-01-01
Summarizes a survey and two experiments designed to compare teachers' and department heads' use of, and attitudes toward, England's A Level Information System (ALIS). Conclusions are linked to theories of change, cybernetics, and a view of education regarding researchers and teachers as coinvestigators. Experimentation within school-effectiveness…
ERIC Educational Resources Information Center
Kourilsky, Marilyn; Hirshleifer, Jack
1976-01-01
This study compares the effects of two teacher training programs designed to emphasize one of two forms of behavior modification in teaching economics to fourth-, fifth-, and sixth-grade pupils. (DMT)
Design and Computational/Experimental Analysis of Low Sonic Boom Configurations
NASA Technical Reports Server (NTRS)
Cliff, Susan E.; Baker, Timothy J.; Hicks, Raymond M.
1999-01-01
Recent studies have shown that inviscid CFD codes combined with a planar extrapolation method give accurate sonic boom pressure signatures at distances greater than one body length from supersonic configurations if either adapted grids swept at the approximate Mach angle or very dense non-adapted grids are used. The validation of CFD for computing sonic boom pressure signatures provided the confidence needed to undertake the design of new supersonic transport configurations with low sonic boom characteristics. An aircraft synthesis code in combination with CFD and an extrapolation method were used to close the design. The principal configuration of this study is designated LBWT (Low Boom Wing Tail) and has a highly swept cranked arrow wing with conventional tails, and was designed to accommodate either 3 or 4 engines. The complete configuration including nacelles and boundary layer diverters was evaluated using the AIRPLANE code. This computer program solves the Euler equations on an unstructured tetrahedral mesh. Computations and wind tunnel data for the LBWT and two other low boom configurations designed at NASA Ames Research Center are presented. The two additional configurations are included to provide a basis for comparing the performance and sonic boom level of the LBWT with contemporary low boom designs and to give a broader experiment/CFD correlation study. The computational pressure signatures for the three configurations are contrasted with on-ground-track near-field experimental data from the NASA Ames 9x7 Foot Supersonic Wind Tunnel. Computed pressure signatures for the LBWT are also compared with experiment at approximately 15 degrees off ground track.
NASA Technical Reports Server (NTRS)
Williams, J. G.; Mikulus, M. M., Jr.
1976-01-01
Structural efficiency studies were made to determine the weight saving potential of graphite/epoxy composite structures for compression panel applications. Minimum weight hat-stiffened and open corrugation configurations were synthesized using a nonlinear mathematical programming technique. Selected configurations were built and tested to study local and Euler buckling characteristics. Test results for 23 panels critical in local buckling and six panels critical in Euler buckling are compared with analytical results obtained using the BUCLASP-2 branched plate buckling program. A weight efficiency comparison is made between composite and aluminum compression panels using metal test data generated by the NACA. Theoretical studies indicate that potential weight savings of up to 50% are possible for composite hat-stiffened panels when compared with similar aluminum designs. Weight savings of 32% to 42% were experimentally achieved. Experience suggests that most of the theoretical weight saving potential is available if design deficiencies are eliminated and strict fabrication control is exercised.
Modulating risky decision-making in Parkinson's disease by transcranial direct current stimulation.
Benussi, A; Alberici, A; Cantoni, V; Manenti, R; Brambilla, M; Dell'Era, V; Gazzina, S; Manes, M; Cristillo, V; Padovani, A; Cotelli, M; Borroni, B
2017-05-01
Performance on gambling tasks in Parkinson's disease (PD) is of particular interest, as pathological gambling is often associated with dopamine replacement therapy in these patients. We aimed to evaluate the effects of transcranial direct current stimulation (tDCS) over the right dorsolateral prefrontal cortex (DLPFC) in modulating gambling behaviour in PD. We assessed the effects of cathodal tDCS over the right DLPFC during the Iowa Gambling Task in 20 patients with PD, compared with sham stimulation. We then conducted a second experimental design, assessing the effects of anodal tDCS over the right DLPFC. We observed that cathodal tDCS over the right DLPFC increased Iowa Gambling Task scores compared with sham stimulation. In the second experimental design, we did not find significant differences between anodal and sham tDCS. Cathodal tDCS over the right DLPFC possibly reduces the pathological overdrive in frontostriatal networks in patients with PD on dopaminergic medication, thus modulating impulsive and risky decision-making. © 2017 EAN.
Xu, Lingyang; Hou, Yali; Bickhart, Derek M; Song, Jiuzhou; Liu, George E
2013-06-25
Copy number variations (CNVs) are gains and losses of genomic sequence between two individuals of a species when compared to a reference genome. The data from single nucleotide polymorphism (SNP) microarrays are now routinely used for genotyping, but they also can be utilized for copy number detection. Substantial progress has been made in array design and CNV calling algorithms and at least 10 comparison studies in humans have been published to assess them. In this review, we first survey the literature on existing microarray platforms and CNV calling algorithms. We then examine a number of CNV calling tools to evaluate their impacts using bovine high-density SNP data. Large incongruities in the results from different CNV calling tools highlight the need for standardizing array data collection, quality assessment and experimental validation. Only after careful experimental design and rigorous data filtering can the impacts of CNVs on both normal phenotypic variability and disease susceptibility be fully revealed.
NASA Astrophysics Data System (ADS)
He, Jianmei
2017-11-01
Present metal artificial bones for bone grafts have the problems like too heavy and excessive elastic modulus compared with natural bones. In this study, three-dimensionally (3D) free-formable titanium mesh plates for bone graft applications was introduced to improve these problems. Fundamental mesh shapes and patterns were designed under different base shapes and design parameters through three dimensional CAD tools from higher flexibility and strength points of view. Based on the designed mesh shape and patterns, sample specimens of titanium mesh plates with different base shapes and design variables were manufactured through laser processing. Tensile properties of the sample titanium mesh plates like volume density, tensile elastic modulus were experimentally and analytically evaluated. Experimental results showed that such titanium mesh plates had much higher flexibility and their mechanical properties could be controlled to close to the natural bones. More details on the mechanical properties of titanium mesh plates including compression, bending, torsion and durability will be carried out in future study.
Leong, H M; Carter, Mark; Stephenson, Jennifer
2015-12-01
Sensory integration therapy (SIT) is a controversial intervention that is widely used for people with disabilities. Systematic analysis was conducted on the outcomes of 17 single case design studies on sensory integration therapy for people with, or at-risk of, a developmental or learning disability, disorder or delay. An assessment of the quality of methodology of the studies found most used weak designs and poor methodology, with a tendency for higher quality studies to produce negative results. Based on limited comparative evidence, functional analysis-based interventions for challenging behavior were more effective that SIT. Overall the studies do not provide convincing evidence for the efficacy of sensory integration therapy. Given the findings of the present review and other recent analyses it is advised that the use of SIT be limited to experimental contexts. Issues with the studies and possible improvements for future research are discussed including the need to employ designs that allow for adequate demonstration of experimental control. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ahn, Heejung; Kim, Hyun-Young
2015-05-01
This study is involved in designing high-fidelity simulations reflecting the Korean nursing education environment. In addition, it evaluated the simulations by nursing students' learning outcomes and perceptions of the simulation design features. A quantitative design was used in two separate phases. For the first phase, five nursing experts participated in verifying the appropriateness of two simulation scenarios that reflected the intended learning objectives. For the second phase, 69 nursing students in the third year of a bachelor's degree at a nursing school participated in evaluating the simulations and were randomized according to their previous course grades. The first phase verified the two simulation scenarios using a questionnaire. The second phase evaluated students' perceptions of the simulation design, self-confidence, and critical thinking skills using a quasi-experimental post-test design. ANCOVA was used to compare the experimental and control groups, and correlation coefficient analysis was used to determine the correlation among them. We created 2 simulation scenarios to integrate cognitive and psychomotor skills according to the learning objectives and clinical environment in Korea. The experimental group had significantly higher scores on self-confidence in the first scenario. The positive correlations between perceptions of the simulation design features, self-confidence, and critical thinking skill scores were statistically significant. Students with a more positive perception of the design features of the simulations had better learning outcomes. Based on this result, simulations need to be designed and implemented with more differentiation in order to be perceived more appropriately by students. Copyright © 2015 Elsevier Ltd. All rights reserved.
Computational design and experimental verification of a symmetric protein homodimer.
Mou, Yun; Huang, Po-Ssu; Hsu, Fang-Ciao; Huang, Shing-Jong; Mayo, Stephen L
2015-08-25
Homodimers are the most common type of protein assembly in nature and have distinct features compared with heterodimers and higher order oligomers. Understanding homodimer interactions at the atomic level is critical both for elucidating their biological mechanisms of action and for accurate modeling of complexes of unknown structure. Computation-based design of novel protein-protein interfaces can serve as a bottom-up method to further our understanding of protein interactions. Previous studies have demonstrated that the de novo design of homodimers can be achieved to atomic-level accuracy by β-strand assembly or through metal-mediated interactions. Here, we report the design and experimental characterization of a α-helix-mediated homodimer with C2 symmetry based on a monomeric Drosophila engrailed homeodomain scaffold. A solution NMR structure shows that the homodimer exhibits parallel helical packing similar to the design model. Because the mutations leading to dimer formation resulted in poor thermostability of the system, design success was facilitated by the introduction of independent thermostabilizing mutations into the scaffold. This two-step design approach, function and stabilization, is likely to be generally applicable, especially if the desired scaffold is of low thermostability.
NASA Astrophysics Data System (ADS)
Yang, Jin; Hu, Chuxiong; Zhu, Yu; Wang, Ze; Zhang, Ming
2017-08-01
In this paper, shaping disturbance observer (SDOB) is investigated for precision mechatronic stages with middle-frequency zero/pole type resonance to achieve good motion control performance in practical manufacturing situations. Compared with traditional standard disturbance observer (DOB), in SDOB a pole-zero cancellation based shaping filter is cascaded to the mechatronic stage plant to meet the challenge of motion control performance deterioration caused by actual resonance. Noting that pole-zero cancellation is inevitably imperfect and the controller may even consequently become unstable in practice, frequency domain stability analysis is conducted to find out how each parameter of the shaping filter affects the control stability. Moreover, the robust design criterion of the shaping filter, and the design procedure of SDOB, are both proposed to guide the actual design and facilitate practical implementation. The SDOB with the proposed design criterion is applied to a linear motor driven stage and a voice motor driven stage, respectively. Experimental results consistently validate the effectiveness nature of the proposed SDOB scheme in practical mechatronics motion applications. The proposed SDOB design actually could be an effective unit in the controller design for motion stages of mechanical manufacture equipments.
Oluyomi, Abiodun O; Byars, Allison; Byrd-Williams, Courtney; Sharma, Shreela V; Durand, Casey; Hoelscher, Deanna M; Butte, Nancy F; Kelder, Steven H
2015-02-01
The Texas Childhood Obesity Research Demonstration project (TX CORD) uses a systems-oriented approach to address obesity that includes individual and family interventions, community-level action, as well as environmental and policy initiatives. Given that randomization is seldom possible in community-level intervention studies, TX CORD uses a quasi-experimental design. Comparable intervention and comparison study sites are needed to address internal validity bias. TX CORD was designed to be implemented in low-income, ethnically diverse communities in Austin and Houston, Texas. A three-stage Geographical Information System (GIS) methodology was used to establish and ascertain the comparability of the intervention and comparison study sites. Census tract (stage 1) and school (stage 2) data were used to identify spatially exclusive geographic areas that were comparable. In stage 3, study sites were compared on demographic characteristics, socioeconomic status (SES), food assets, and physical activity (PA) assets. Student's t-test was used to examine significant differences between the selected sites. The methodology that was used resulted in the selection of catchment areas with demographic and socioeconomic characteristics that fit the target population: ethnically diverse population; lower-median household income; and lower home ownership rates. Additionally, the intervention and comparison sites were statistically comparable on demographic and SES variables, as well as food assets and PA assets. This GIS approach can provide researchers, program evaluators, and policy makers with useful tools for both research and practice. Area-level information that allows for robust understanding of communities can enhance analytical procedures in community health research and offer significant contributions in terms of community assessment and engagement.
1977-05-01
An experiment, designed to introduce time management concepts, was conducted with 33 volunteers from a Department of the Navy PMO -- the experimental...group. The instruments used to conduct the experiment were a Time Management Survey and a Time Management Questionnaire. The survey was used to...data obtained from the experimental group were statistically compared with similar data from a control group. Time management principles and ’tips’ on
Quiet Clean Short-haul Experimental Engine (QCSEE) clean combustor test report
NASA Technical Reports Server (NTRS)
1975-01-01
A component pressure test was conducted on a F101 PFRT combustor to evaluate the emissions levels of this combustor design at selected under the wing and over the wing operating conditions for the quiet clean short haul experimental engine (QCSEE). Emissions reduction techniques were evaluated which included compressor discharge bleed and sector burning in the combustor. The results of this test were utilized to compare the expected QCSEE emissions levels with the emission goals of the QCSEE engine program.
Inertial focusing of microparticles and its limitations
NASA Astrophysics Data System (ADS)
Cruz, FJ; Hooshmand Zadeh, S.; Wu, ZG; Hjort, K.
2016-10-01
Microfluidic devices are useful tools for healthcare, biological and chemical analysis and materials synthesis amongst fields that can benefit from the unique physics of these systems. In this paper we studied inertial focusing as a tool for hydrodynamic sorting of particles by size. Theory and experimental results are provided as a background for a discussion on how to extend the technology to submicron particles. Different geometries and dimensions of microchannels were designed and simulation data was compared to the experimental results.
Dawes, Donald Murray; Ho, Jeffrey D; Moore, Johanna C; Miner, James R
2013-09-01
Despite human laboratory and field studies that have demonstrated a reasonable safety profile for TASER brand conducted electrical weapons (CEW), the results of some swine studies and arrest related deaths temporal to the use of the CEWs continue to raise questions regarding cardiac safety. TASER International, Inc., has released a new CEW, the TASER X2, touted to have a better safety profile than its long-standing predecessor, the TASER X26. We have developed a model to assess the relative cardiac safety of CEWs and used it to compare the TASER X2 and the TASER X26. This safety model was also used to assess the relative safety of an experimental probe design as compared to the standard steel probe. Our results suggest that the TASER X2 has an improved safety margin over the TASER X26. The new probe design also has promise for enhanced cardiac safety, although may have some disadvantages when compared to the existing design which would make field use impractical.
Experimental testing of prototype face gears for helicopter transmissions
NASA Technical Reports Server (NTRS)
Handschuh, R.; Lewicki, D.; Bossler, R.
1992-01-01
An experimental program to test the feasibility of using face gears in a high-speed and high-power environment was conducted. Four face gear sets were tested, two sets at a time, in a closed-loop test stand at pinion rotational speeds to 19,100 rpm and to 271 kW. The test gear sets were one-half scale of the helicopter design gear set. Testing the gears at one-eighth power, the test gear set had slightly increased bending and compressive stresses when compared to the full scale design. The tests were performed in the LeRC spiral bevel gear test facility. All four sets of gears successfully ran at 100 percent of design torque and speed for 30 million pinion cycles, and two sets successfully ran at 200 percent of torque for an additional 30 million pinion cycles. The results, although limited, demonstrated the feasibility of using face gears for high-speed, high-load applications.
Computational Analysis of a Low-Boom Supersonic Inlet
NASA Technical Reports Server (NTRS)
Chima, Rodrick V.
2011-01-01
A low-boom supersonic inlet was designed for use on a conceptual small supersonic aircraft that would cruise with an over-wing Mach number of 1.7. The inlet was designed to minimize external overpressures, and used a novel bypass duct to divert the highest shock losses around the engine. The Wind-US CFD code was used to predict the effects of capture ratio, struts, bypass design, and angles of attack on inlet performance. The inlet was tested in the 8-ft by 6-ft Supersonic Wind Tunnel at NASA Glenn Research Center. Test results showed that the inlet had excellent performance, with capture ratios near one, a peak core total pressure recovery of 96 percent, and a stable operating range much larger than that of an engine. Predictions generally compared very well with the experimental data, and were used to help interpret some of the experimental results.
Assessing the applicability of the Taguchi design method to an interrill erosion study
NASA Astrophysics Data System (ADS)
Zhang, F. B.; Wang, Z. L.; Yang, M. Y.
2015-02-01
Full-factorial experimental designs have been used in soil erosion studies, but are time, cost and labor intensive, and sometimes they are impossible to conduct due to the increasing number of factors and their levels to consider. The Taguchi design is a simple, economical and efficient statistical tool that only uses a portion of the total possible factorial combinations to obtain the results of a study. Soil erosion studies that use the Taguchi design are scarce and no comparisons with full-factorial designs have been made. In this paper, a series of simulated rainfall experiments using a full-factorial design of five slope lengths (0.4, 0.8, 1.2, 1.6, and 2 m), five slope gradients (18%, 27%, 36%, 48%, and 58%), and five rainfall intensities (48, 62.4, 102, 149, and 170 mm h-1) were conducted. Validation of the applicability of a Taguchi design to interrill erosion experiments was achieved by extracting data from the full dataset according to a theoretical Taguchi design. The statistical parameters for the mean quasi-steady state erosion and runoff rates of each test, the optimum conditions for producing maximum erosion and runoff, and the main effect and percentage contribution of each factor obtained from the full-factorial and Taguchi designs were compared. Both designs generated almost identical results. Using the experimental data from the Taguchi design, it was possible to accurately predict the erosion and runoff rates under the conditions that had been excluded from the Taguchi design. All of the results obtained from analyzing the experimental data for both designs indicated that the Taguchi design could be applied to interrill erosion studies and could replace full-factorial designs. This would save time, labor and costs by generally reducing the number of tests to be conducted. Further work should test the applicability of the Taguchi design to a wider range of conditions.
Stucke, Kathrin; Kieser, Meinhard
2012-12-10
In the three-arm 'gold standard' non-inferiority design, an experimental treatment, an active reference, and a placebo are compared. This design is becoming increasingly popular, and it is, whenever feasible, recommended for use by regulatory guidelines. We provide a general method to calculate the required sample size for clinical trials performed in this design. As special cases, the situations of continuous, binary, and Poisson distributed outcomes are explored. Taking into account the correlation structure of the involved test statistics, the proposed approach leads to considerable savings in sample size as compared with application of ad hoc methods for all three scale levels. Furthermore, optimal sample size allocation ratios are determined that result in markedly smaller total sample sizes as compared with equal assignment. As optimal allocation makes the active treatment groups larger than the placebo group, implementation of the proposed approach is also desirable from an ethical viewpoint. Copyright © 2012 John Wiley & Sons, Ltd.
SCOUT: A Fast Monte-Carlo Modeling Tool of Scintillation Camera Output
Hunter, William C. J.; Barrett, Harrison H.; Lewellen, Thomas K.; Miyaoka, Robert S.; Muzi, John P.; Li, Xiaoli; McDougald, Wendy; MacDonald, Lawrence R.
2011-01-01
We have developed a Monte-Carlo photon-tracking and readout simulator called SCOUT to study the stochastic behavior of signals output from a simplified rectangular scintillation-camera design. SCOUT models the salient processes affecting signal generation, transport, and readout. Presently, we compare output signal statistics from SCOUT to experimental results for both a discrete and a monolithic camera. We also benchmark the speed of this simulation tool and compare it to existing simulation tools. We find this modeling tool to be relatively fast and predictive of experimental results. Depending on the modeled camera geometry, we found SCOUT to be 4 to 140 times faster than other modeling tools. PMID:22072297
SCOUT: a fast Monte-Carlo modeling tool of scintillation camera output†
Hunter, William C J; Barrett, Harrison H.; Muzi, John P.; McDougald, Wendy; MacDonald, Lawrence R.; Miyaoka, Robert S.; Lewellen, Thomas K.
2013-01-01
We have developed a Monte-Carlo photon-tracking and readout simulator called SCOUT to study the stochastic behavior of signals output from a simplified rectangular scintillation-camera design. SCOUT models the salient processes affecting signal generation, transport, and readout of a scintillation camera. Presently, we compare output signal statistics from SCOUT to experimental results for both a discrete and a monolithic camera. We also benchmark the speed of this simulation tool and compare it to existing simulation tools. We find this modeling tool to be relatively fast and predictive of experimental results. Depending on the modeled camera geometry, we found SCOUT to be 4 to 140 times faster than other modeling tools. PMID:23640136
Principles and performance of tapered fiber lasers: from uniform to flared geometry.
Kerttula, Juho; Filippov, Valery; Chamorovskii, Yuri; Ustimchik, Vasily; Golant, Konstantin; Okhotnikov, Oleg G
2012-10-10
We have studied the recently demonstrated concept of fiber lasers based on active tapered double-clad fiber (T-DCF) in copropagating and counterpropagating configurations, both theoretically and experimentally, and compared the performance to fiber lasers based on conventional cylindrical fibers in end-pumped configurations. Specific properties of T-DCFs were considered theoretically using a rate-equation model developed for tapered fibers, and a detailed comparative study was carried out experimentally. Furthermore, we have studied mode coupling effects in long adiabatic tapers due to coiling and local bending. The results allow us to conclude that, with proper fiber design, the T-DCF technology offers a high-potential alternative for bright, cost-effective fiber devices.
Web-Based Integrated Research Environment for Aerodynamic Analyses and Design
NASA Astrophysics Data System (ADS)
Ahn, Jae Wan; Kim, Jin-Ho; Kim, Chongam; Cho, Jung-Hyun; Hur, Cinyoung; Kim, Yoonhee; Kang, Sang-Hyun; Kim, Byungsoo; Moon, Jong Bae; Cho, Kum Won
e-AIRS[1,2], an abbreviation of ‘e-Science Aerospace Integrated Research System,' is a virtual organization designed to support aerodynamic flow analyses in aerospace engineering using the e-Science environment. As the first step toward a virtual aerospace engineering organization, e-AIRS intends to give a full support of aerodynamic research process. Currently, e-AIRS can handle both the computational and experimental aerodynamic research on the e-Science infrastructure. In detail, users can conduct a full CFD (Computational Fluid Dynamics) research process, request wind tunnel experiment, perform comparative analysis between computational prediction and experimental measurement, and finally, collaborate with other researchers using the web portal. The present paper describes those services and the internal architecture of the e-AIRS system.
Design and test of a simulation system for autonomous optic-navigated planetary landing
NASA Astrophysics Data System (ADS)
Cai, Sheng; Yin, Yanhe; Liu, Yanjun; He, Fengyun
2018-02-01
In this paper, a simulation system based on commercial projector is proposed to test the optical navigation algorithms for autonomous planetary landing in laboratorial scenarios. The design work of optics, mechanics and synchronization control are carried out. Furthermore, the whole simulation system is set up and tested. Through the calibration of the system, two main problems, synchronization between the projector and CCD and pixel-level shifting caused by the low repeatability of DMD used in the projector, are settled. The experimental result shows that the RMS errors of pitch, yaw and roll angles are 0.78', 0.48', and 2.95' compared with the theoretical calculation, which can fulfill the requirement of experimental simulation for planetary landing in laboratory.
Pivovarova, T A; Bulaev, A G; Roshchupko, P V; Belyĭ, A V; Kondrat'eva, T F
2012-01-01
Aboriginal and experimental (constructed of pure microbial cultures) communities of acidophilic chemolithotrophs have been studied. The oxidation of elemental sulfur, sodium thiosulfate, and potassium tetrathionate as sole sources of energy has been monitored. The oxidation rate of the experimental community is higher as compared to the aboriginal community isolated from a flotation concentrate of pyrrhotine-containing pyrite-arsenopyrite gold-arsenic sulfide ore. The degree of oxidation of the mentioned S substrates amounts to 17.91, 68.30, and 93.94% for the experimental microbial community and to 10.71, 56.03, and 79.50% for the aboriginal community, respectively. The degree of oxidation of sulfur sulfide forms in the ore flotation concentrate is 59.15% by the aboriginal microbial community and 49.40% by the experimental microbial community. Despite a higher rate of oxidation of S substrates as a sole source of energy by the experimental microbial community, the aboriginal community oxidizes S substrates at a higher rate in the flotation concentrate of pyrrhotine-containing pyrite-arsenopyrite gold-arsenic sulfide ore, from which it was isolated. Bacterial-chemical oxidation of the flotation concentrate by the aboriginal microbial community allows for the extraction of an additional 32.3% of gold from sulfide minerals, which is by 5.7% larger compared to the yield obtained by the experimental microbial community.
Sub-Nanoliter Spectroscopic Gas Sensor
Alfeeli, Bassam; Pickrell, Gary; Wang, Anbo
2006-01-01
In this work, a new type of optical fiber based chemical sensor, the sub-nanoliter sample cell (SNSC) based gas sensor, is described and compared to existing sensors designs in the literature. This novel SNSC gas sensor is shown to have the capability of gas detection with a cell volume in the sub-nanoliter range. Experimental results for various configurations of the sensor design are presented which demonstrate the capabilities of the miniature gas sensor.
ERIC Educational Resources Information Center
Blank, Rolf K.
2004-01-01
The purpose of the three-year CCSSO study was to design, implement, and test the effectiveness of the Data on Enacted Curriculum (DEC) model for improving math and science instruction. The model was tested by measuring its effects with a randomly selected sample of ?treatment? schools at the middle grades level as compared to a control group of…
Experimental Mapping and Benchmarking of Magnetic Field Codes on the LHD Ion Accelerator
NASA Astrophysics Data System (ADS)
Chitarin, G.; Agostinetti, P.; Gallo, A.; Marconato, N.; Nakano, H.; Serianni, G.; Takeiri, Y.; Tsumori, K.
2011-09-01
For the validation of the numerical models used for the design of the Neutral Beam Test Facility for ITER in Padua [1], an experimental benchmark against a full-size device has been sought. The LHD BL2 injector [2] has been chosen as a first benchmark, because the BL2 Negative Ion Source and Beam Accelerator are geometrically similar to SPIDER, even though BL2 does not include current bars and ferromagnetic materials. A comprehensive 3D magnetic field model of the LHD BL2 device has been developed based on the same assumptions used for SPIDER. In parallel, a detailed experimental magnetic map of the BL2 device has been obtained using a suitably designed 3D adjustable structure for the fine positioning of the magnetic sensors inside 27 of the 770 beamlet apertures. The calculated values have been compared to the experimental data. The work has confirmed the quality of the numerical model, and has also provided useful information on the magnetic non-uniformities due to the edge effects and to the tolerance on permanent magnet remanence.
Learning and performance under alternative instructional manifestations of experimental practice
NASA Astrophysics Data System (ADS)
Ford, Michael J.
Before we can understand how students learn "to do" science, we must make explicit our assumptions about what scientific practice is. This study compares the learning outcomes of two sixth-grade instructional units on experimentation, each based on a particular characterization of practice. In one unit, instruction focused on acquisition and application of the control of variables strategy (CVS; Chen & Klahr, 1999), which is consistent with a popular conception of science education, stemming from Piaget, as the mastery of logical forms. In the other unit, students designed experimental apparatus to answer a target question, and instruction emphasized practices of rendering and transforming the material world in ways that support scientific understanding. Students in both groups were assessed for CVS acquisition and subsequent experimental performance on a novel task, and group performances on these assessments different across instructional conditions. I will argue that student understandings of goals, norms of instructional expectation, and strategies explain these differences, in some cases by supporting performance and in other cases by hindering it. I will also argue that the results question the role typically attributed to logical method in learning to design experiments.
Experimental Mapping and Benchmarking of Magnetic Field Codes on the LHD Ion Accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chitarin, G.; University of Padova, Dept. of Management and Engineering, strad. S. Nicola, 36100 Vicenza; Agostinetti, P.
2011-09-26
For the validation of the numerical models used for the design of the Neutral Beam Test Facility for ITER in Padua [1], an experimental benchmark against a full-size device has been sought. The LHD BL2 injector [2] has been chosen as a first benchmark, because the BL2 Negative Ion Source and Beam Accelerator are geometrically similar to SPIDER, even though BL2 does not include current bars and ferromagnetic materials. A comprehensive 3D magnetic field model of the LHD BL2 device has been developed based on the same assumptions used for SPIDER. In parallel, a detailed experimental magnetic map of themore » BL2 device has been obtained using a suitably designed 3D adjustable structure for the fine positioning of the magnetic sensors inside 27 of the 770 beamlet apertures. The calculated values have been compared to the experimental data. The work has confirmed the quality of the numerical model, and has also provided useful information on the magnetic non-uniformities due to the edge effects and to the tolerance on permanent magnet remanence.« less
NASA Technical Reports Server (NTRS)
Hirt, Stefanie M.; Anderson, Bernhard H.
2009-01-01
The effectiveness of microramp flow control devices in controlling an oblique shock interaction was tested in the 15- by 15-Centimeter Supersonic Wind Tunnel at NASA Glenn Research Center. Fifteen microramp geometries were tested varying the height, chord length, and spacing between ramps. Measurements of the boundary layer properties downstream of the shock reflection were analyzed using design of experiments methods. Results from main effects, D-optimal, full factorial, and central composite designs were compared. The designs provided consistent results for a single variable optimization.
NASA Astrophysics Data System (ADS)
Lertwanasiriwan, Chaiwuti
The study examined the effects of a technology-enhanced inquiry instructional model on students' understanding of science in Thailand. A mixed quantitative research design was selected for the research design. A pretest-posttest control-group design was implemented for the experimental research. A causal-comparative design using questionnaire and classroom observation was employed for the non-experimental research. Two sixth-grade classrooms at a medium-sized public school in Bangkok, Thailand were randomly selected for the study - one as the control group and the other as the experimental group. The 34 students in the control group only received the inquiry instructional model, while the 35 students in the experimental group received the technology-enhanced inquiry instructional model. Both groups of students had been taught by the same science teacher for 15 weeks (three periods per week). The results and findings from the study seemed to indicate that both the technology-enhanced inquiry instructional model and the inquiry instructional model significantly improve students' understanding of science. However, it might be claimed that students receiving the technology-enhanced inquiry instructional model gain more than students only receiving the inquiry instructional model. In addition, the technology-enhanced inquiry instructional model seemed to support the assessment during the 5E Model's evaluation stage. Most students appeared to have very good attitudes toward using it in the science classroom suggesting that the technology-enhanced inquiry instructional model motivates students to learn science.
Rapid Structural Design Change Evaluation with AN Experiment Based FEM
NASA Astrophysics Data System (ADS)
Chu, C.-H.; Trethewey, M. W.
1998-04-01
The work in this paper proposes a dynamic structural design model that can be developed in a rapid fashion. The approach endeavours to produce a simplified FEM developed in conjunction with an experimental modal database. The FEM is formulated directly from the geometry and connectivity used in an experimental modal test using beam/frame elements. The model sacrifices fine detail for a rapid development time. The FEM is updated at the element level so the dynamic response replicates the experimental results closely. The physical attributes of the model are retained, making it well suited to evaluate the effect of potential design changes. The capabilities are evaluated in a series of computational and laboratory tests. First, a study is performed with a simulated cantilever beam with a variable mass and stiffness distribution. The modal characteristics serve as the updating target with random noise added to simulate experimental uncertainty. A uniformly distributed FEM is developed and updated. The results show excellent results, all natural frequencies are within 0·001% with MAC values above 0·99. Next, the method is applied to predict the dynamic changes of a hardware portal frame structure for a radical design change. Natural frequency predictions from the original FEM differ by as much as almost 18% with reasonable MAC values. The results predicted from the updated model produce excellent results when compared to the actual hardware changes, the first five modal natural frequency difference is around 5% and the corresponding mode shapes producing MAC values above 0·98.
An experimental loop design for the detection of constitutional chromosomal aberrations by array CGH
2009-01-01
Background Comparative genomic hybridization microarrays for the detection of constitutional chromosomal aberrations is the application of microarray technology coming fastest into routine clinical application. Through genotype-phenotype association, it is also an important technique towards the discovery of disease causing genes and genomewide functional annotation in human. When using a two-channel microarray of genomic DNA probes for array CGH, the basic setup consists in hybridizing a patient against a normal reference sample. Two major disadvantages of this setup are (1) the use of half of the resources to measure a (little informative) reference sample and (2) the possibility that deviating signals are caused by benign copy number variation in the "normal" reference instead of a patient aberration. Instead, we apply an experimental loop design that compares three patients in three hybridizations. Results We develop and compare two statistical methods (linear models of log ratios and mixed models of absolute measurements). In an analysis of 27 patients seen at our genetics center, we observed that the linear models of the log ratios are advantageous over the mixed models of the absolute intensities. Conclusion The loop design and the performance of the statistical analysis contribute to the quick adoption of array CGH as a routine diagnostic tool. They lower the detection limit of mosaicisms and improve the assignment of copy number variation for genetic association studies. PMID:19925645
Allemeersch, Joke; Van Vooren, Steven; Hannes, Femke; De Moor, Bart; Vermeesch, Joris Robert; Moreau, Yves
2009-11-19
Comparative genomic hybridization microarrays for the detection of constitutional chromosomal aberrations is the application of microarray technology coming fastest into routine clinical application. Through genotype-phenotype association, it is also an important technique towards the discovery of disease causing genes and genomewide functional annotation in human. When using a two-channel microarray of genomic DNA probes for array CGH, the basic setup consists in hybridizing a patient against a normal reference sample. Two major disadvantages of this setup are (1) the use of half of the resources to measure a (little informative) reference sample and (2) the possibility that deviating signals are caused by benign copy number variation in the "normal" reference instead of a patient aberration. Instead, we apply an experimental loop design that compares three patients in three hybridizations. We develop and compare two statistical methods (linear models of log ratios and mixed models of absolute measurements). In an analysis of 27 patients seen at our genetics center, we observed that the linear models of the log ratios are advantageous over the mixed models of the absolute intensities. The loop design and the performance of the statistical analysis contribute to the quick adoption of array CGH as a routine diagnostic tool. They lower the detection limit of mosaicisms and improve the assignment of copy number variation for genetic association studies.
Lecheb, Fatma; Benamara, Salem
2015-01-01
This article reports on the feasibility study of a cosmetic cream added with aqueous extract and oil from date (Phoenix dactylifera L.) fruit seed using experimental design. First, the mixture design was applied to optimize the cosmetic formula. The responses (dependent variables) were the spreadability (YSp) and viscosity (YVis), the factors (independent variables) being the weight proportions of the fatty phase (X1), the aqueous date seed extract (X2), and the beeswax (X3). Second, the cosmetic stability study was conducted by applying a full factorial design. Here, three responses were considered [spreadability (Sp), viscosity (Vis), and peroxide index (PI)], the independent variables being the concentration of the date seed oil (DSO) (x1), storage temperature (x2), and storage time (x3). Results showed that in the case of mixture design, the second-order polynomial equations correctly described experimental data. Globally, results show that there is a relatively wide composition range to ensure a suitable cosmetic cream from the point of view of Sp and Vis. Regarding the cosmetic stability, the storage time was found to be the most influential factor on both Vis and PI, which are considered here as indicators of physical and chemical stability of the emulsion, respectively. Finally, the elaborated and commercial cosmetics were compared in terms of pH, Sp, and centrifugation test (Ct).
Experiments and analysis of a compact electrothermal thruster
NASA Technical Reports Server (NTRS)
Asmussen, Jes; Whitehair, Stan
1988-01-01
The description and experimental performance of a compact microwave electrothermal thruster (MET) are presented. This thruster uses a coaxial applicator to couple microwave power into a high pressure discharge. Unlike earlier experiments, it uses no fused quartz in the discharge chamber or the nozzle. This allows high temperatures in the discharge chamber without quartz erosion and melting, thereby improving thruster performance and lifetime. The thruster design is compact, enhancing its potential as a space engine. Experimental tests using nitrogen and helium propellants with input powers levels of 200 W to 1.5 kW are presented. Experimental results, which produce energy efficiencies of 20 to 60 percent and specific impulse of 250 to 450 sec, compare favorably to previous experimental MET performance.
Investigation of culvert hydraulics related to juvenile fish passage. Final research report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barber, M.E.; Downs, R.C.
1996-01-01
Culverts often create barriers to the upstream migration of juvenile fish. The objective of this study was to determine hydraulic characteristics of culverts with different flow conditions. Methods of predicting flow profiles were developed by both Chiu and Mountjoy. Two equations were compared to experimental results. An area of flow corresponding to a predetermined allowable velocity can be calculated using Mountjoy equation. This can then be used in the design of culverts as fish passage guidelines. The report contains a summary of background information, experimental methodology, the results of experimental tests, and an analysis of both the Chiu and Mountjoymore » equations.« less
Baldo, Matías N; Angeli, Emmanuel; Gareis, Natalia C; Hunzicker, Gabriel A; Murguía, Marcelo C; Ortega, Hugo H; Hein, Gustavo J
2018-04-01
A relative bioavailability study (RBA) of two phenytoin (PHT) formulations was conducted in rabbits, in order to compare the results obtained from different matrices (plasma and blood from dried blood spot (DBS) sampling) and different experimental designs (classic and block). The method was developed by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in plasma and blood samples. The different sample preparation techniques, plasma protein precipitation and DBS, were validated according to international requirements. The analytical method was validated with ranges 0.20-50.80 and 0.12-20.32 µg ml -1 , r > 0.999 for plasma and blood, respectively. Accuracy and precision were within acceptance criteria for bioanalytical assay validation (< 15 for bias and CV% and < 20 for limit of quantification (LOQ)). PHT showed long-term stability, both for plasma and blood, and under refrigerated and room temperature conditions. Haematocrit values were measured during the validation process and RBA study. Finally, the pharmacokinetic parameters (C max , T max and AUC 0-t ) obtained from the RBA study were tested. Results were highly comparable for matrices and experimental designs. A matrix correlation higher than 0.975 and a ratio of (PHT blood) = 1.158 (PHT plasma) were obtained. The results obtained herein show that the use of classic experimental design and DBS sampling for animal pharmacokinetic studies should be encouraged as they could help to prevent the use of a large number of animals and also animal euthanasia. Finally, the combination of DBS sampling with LC-MS/MS technology showed to be an excellent tool not only for therapeutic drug monitoring but also for RBA studies.
Effects of revised consultation room design on patient-physician communication.
Ajiboye, Folaranmi; Dong, Fanglong; Moore, Justin; Kallail, K James; Baughman, Allison
2015-01-01
To evaluate the impact of a revised consultation room design on patient-physician interaction in an outpatient setting. The growth of ambulatory medical care makes outpatient facilities the primary point of health care contact for many Americans. However, the outpatient consultation room design remains largely unchanged, despite its increased use and the adoption of technology-mediated information sharing in clinical encounter. A randomized controlled trial used a postvisit questionnaire to assess six domains of interest (satisfaction with the visit and the consultation room, mutual respect, patient trust in the physician, communication quality, people-room interaction, and interpersonal-room interaction) in two different room designs (a traditional room and an experimental room in which a pedestal table had replaced the examination table). Interpersonal-room interaction was enhanced in the experimental consultation room when compared to the traditional consultation room (p = .0038). Participants in the experimental consultation room had better access to the computer screen, increased provider information sharing, and more time engaging providers in conversation about information on the monitor. Changing the layout of a consultation room has the potential to improve interpersonal communication through better information sharing. Clinicians who are interested in maximizing the benefits of their clinical encounter should consider changing the layout of their consultation room, especially the positioning of the computer screen. © The Author(s) 2014.
Two-sample binary phase 2 trials with low type I error and low sample size
Litwin, Samuel; Basickes, Stanley; Ross, Eric A.
2017-01-01
Summary We address design of two-stage clinical trials comparing experimental and control patients. Our end-point is success or failure, however measured, with null hypothesis that the chance of success in both arms is p0 and alternative that it is p0 among controls and p1 > p0 among experimental patients. Standard rules will have the null hypothesis rejected when the number of successes in the (E)xperimental arm, E, sufficiently exceeds C, that among (C)ontrols. Here, we combine one-sample rejection decision rules, E ≥ m, with two-sample rules of the form E – C > r to achieve two-sample tests with low sample number and low type I error. We find designs with sample numbers not far from the minimum possible using standard two-sample rules, but with type I error of 5% rather than 15% or 20% associated with them, and of equal power. This level of type I error is achieved locally, near the stated null, and increases to 15% or 20% when the null is significantly higher than specified. We increase the attractiveness of these designs to patients by using 2:1 randomization. Examples of the application of this new design covering both high and low success rates under the null hypothesis are provided. PMID:28118686
Comparison of Coupled Radiative Flow Solutions with Project Fire 2 Flight Data
NASA Technical Reports Server (NTRS)
Olynick, David R.; Henline, W. D.; Chambers, Lin Hartung; Candler, G. V.
1995-01-01
A nonequilibrium, axisymmetric, Navier-Stokes flow solver with coupled radiation has been developed for use in the design or thermal protection systems for vehicles where radiation effects are important. The present method has been compared with an existing now and radiation solver and with the Project Fire 2 experimental data. Good agreement has been obtained over the entire Fire 2 trajectory with the experimentally determined values of the stagnation radiation intensity in the 0.2-6.2 eV range and with the total stagnation heating. The effects of a number of flow models are examined to determine which combination of physical models produces the best agreement with the experimental data. These models include radiation coupling, multitemperature thermal models, and finite rate chemistry. Finally, the computational efficiency of the present model is evaluated. The radiation properties model developed for this study is shown to offer significant computational savings compared to existing codes.
Artificial warming of arctic meadow under pollution stress: Experimental design
USDA-ARS?s Scientific Manuscript database
Boreal and arctic terrestrial ecosystems are central to the climate change debate, notably because future warming is expected to be disproportionate as compared to world averages. Likewise, greenhouse gas (GHG) release from terrestrial ecosystems exposed to climate warming is expected to be the larg...
Meaningful Engagement in Facebook Learning Environments: Merging Social and Academic Lives
ERIC Educational Resources Information Center
Wang, Jenny; Lin, Chun-Fu C.; Yu, Wei-Chieh W.; Wu, Emily
2013-01-01
This study compared the effectiveness of different learning environments between interactive Facebook instructional method and non-Facebook instructional method for undergraduate students. Two outcome dimensions were measured: student grades and learning engagement. A pre-test-posttest control group experimental design was used. The experimental…
Performance evaluation of a newly developed variable rate sprayer for nursery liner applications
USDA-ARS?s Scientific Manuscript database
An experimental variable-rate sprayer designed for liner applications was tested by comparing its spray deposit, coverage, and droplet density inside canopies of six nursery liner varieties with constant-rate applications. Spray samplers, including water sensitive papers (WSP) and nylon screens, wer...
Teaching for Change: Learning Partnerships and Epistemological Growth
ERIC Educational Resources Information Center
Olsen, Deborah; Bekken, Barbara M.; McConnell, Kathryne Drezek; Walter, Charles T.
2011-01-01
Baxter Magolda's Learning Partnerships model was used to create a program designed to foster student epistemological development. To assess its effectiveness, the Measure of Epistemological Reflection was administered to the experimental cohort and a comparable group in the traditional general education program. Results indicate that the model…
Simultaneous Inference Using Finite Intersection Tests: A Better Mousetrap.
ERIC Educational Resources Information Center
Timm, Neil H.
1995-01-01
The finite intersection test (FIT) developed by P. K. Krishnaiah (1964, 1965) is discussed and compared with more familiar methods for simultaneous inference. How the FIT can be used to analyze differences among all means for both univariate and multivariate experimental designs is explained. (SLD)
ERIC Educational Resources Information Center
Kashani, Hajar; Mahmud, Rosnaini Binti; Kalajahi, Seyed Ali Rezvani
2013-01-01
In today's world, there are lots of methods in language teaching in general and teaching writing in particular. Using two different tools in writing essays and conducting a study to compare the effectiveness of these two tools namely blog and pen-and-paper was the basis of this study. This study used a quantitative true experimental design aimed…
ERIC Educational Resources Information Center
Baki, Adnan; Kosa, Temel; Guven, Bulent
2011-01-01
The study compared the effects of dynamic geometry software and physical manipulatives on the spatial visualisation skills of first-year pre-service mathematics teachers. A pre- and post-test quasi-experimental design was used. The Purdue Spatial Visualisation Test (PSVT) was used for the pre- and post-test. There were three treatment groups. The…
Comparative Resuscitation Measures for Drug Toxicities Utilizing Lipid Emulsions
2015-01-13
experimental, mixed research design Methods: For each drug studied, seven swine were assigned to eight ACLS or BLS protocol resuscitation groups ...studied drug overdose. For example, with bupivacaine, seventy- one percent of the epinephrine/lipid group survived compared to 19% of all the groups ...surviving. The Epinephrine only group yielded three survivors and the Lipid emulsion only group yielded one survivor. No swine in the CPR only or
A virtual experimenter to increase standardization for the investigation of placebo effects.
Horing, Bjoern; Newsome, Nathan D; Enck, Paul; Babu, Sabarish V; Muth, Eric R
2016-07-18
Placebo effects are mediated by expectancy, which is highly influenced by psychosocial factors of a treatment context. These factors are difficult to standardize. Furthermore, dedicated placebo research often necessitates single-blind deceptive designs where biases are easily introduced. We propose a study protocol employing a virtual experimenter - a computer program designed to deliver treatment and instructions - for the purpose of standardization and reduction of biases when investigating placebo effects. To evaluate the virtual experimenter's efficacy in inducing placebo effects via expectancy manipulation, we suggest a partially blinded, deceptive design with a baseline/retest pain protocol (hand immersions in hot water bath). Between immersions, participants will receive an (actually inert) medication. Instructions pertaining to the medication will be delivered by one of three metaphors: The virtual experimenter, a human experimenter, and an audio/text presentation (predictor "Metaphor"). The second predictor includes falsely informing participants that the medication is an effective pain killer, or correctly informing them that it is, in fact, inert (predictor "Instruction"). Analysis will be performed with hierarchical linear modelling, with a sample size of N = 50. Results from two pilot studies are presented that indicate the viability of the pain protocol (N = 33), and of the virtual experimenter software and placebo manipulation (N = 48). It will be challenging to establish full comparability between all metaphors used for instruction delivery, and to account for participant differences in acceptance of their virtual interaction partner. Once established, the presence of placebo effects would suggest that the virtual experimenter exhibits sufficient cues to be perceived as a social agent. He could consequently provide a convenient platform to investigate effects of experimenter behavior, or other experimenter characteristics, e.g., sex, age, race/ethnicity or professional status. More general applications are possible, for example in psychological research such as bias research, or virtual reality research. Potential applications also exist for standardizing clinical research by documenting and communicating instructions used in clinical trials.
Junker, Astrid; Muraya, Moses M.; Weigelt-Fischer, Kathleen; Arana-Ceballos, Fernando; Klukas, Christian; Melchinger, Albrecht E.; Meyer, Rhonda C.; Riewe, David; Altmann, Thomas
2015-01-01
Detailed and standardized protocols for plant cultivation in environmentally controlled conditions are an essential prerequisite to conduct reproducible experiments with precisely defined treatments. Setting up appropriate and well defined experimental procedures is thus crucial for the generation of solid evidence and indispensable for successful plant research. Non-invasive and high throughput (HT) phenotyping technologies offer the opportunity to monitor and quantify performance dynamics of several hundreds of plants at a time. Compared to small scale plant cultivations, HT systems have much higher demands, from a conceptual and a logistic point of view, on experimental design, as well as the actual plant cultivation conditions, and the image analysis and statistical methods for data evaluation. Furthermore, cultivation conditions need to be designed that elicit plant performance characteristics corresponding to those under natural conditions. This manuscript describes critical steps in the optimization of procedures for HT plant phenotyping systems. Starting with the model plant Arabidopsis, HT-compatible methods were tested, and optimized with regard to growth substrate, soil coverage, watering regime, experimental design (considering environmental inhomogeneities) in automated plant cultivation and imaging systems. As revealed by metabolite profiling, plant movement did not affect the plants' physiological status. Based on these results, procedures for maize HT cultivation and monitoring were established. Variation of maize vegetative growth in the HT phenotyping system did match well with that observed in the field. The presented results outline important issues to be considered in the design of HT phenotyping experiments for model and crop plants. It thereby provides guidelines for the setup of HT experimental procedures, which are required for the generation of reliable and reproducible data of phenotypic variation for a broad range of applications. PMID:25653655
Design of electrical stimulation bioreactors for cardiac tissue engineering.
Tandon, N; Marsano, A; Cannizzaro, C; Voldman, J; Vunjak-Novakovic, G
2008-01-01
Electrical stimulation has been shown to improve functional assembly of cardiomyocytes in vitro for cardiac tissue engineering. Carbon electrodes were found in past studies to have the best current injection characteristics. The goal of this study was to develop rational experimental design principles for the electrodes and stimulation regime, in particular electrode configuration, electrode ageing, and stimulation amplitude. Carbon rod electrodes were compared via electrochemical impedance spectroscopy (EIS) and we identified a safety range of 0 to 8 V/cm by comparing excitation thresholds and maximum capture rates for neonatal rat cardiomyocytes cultured with electrical stimulation. We conclude with recommendations for studies involving carbon electrodes for cardiac tissue engineering.
Experimental investigation of the crashworthiness of scaled composite sailplane fuselages
NASA Technical Reports Server (NTRS)
Kampf, Karl-Peter; Crawley, Edward F.; Hansman, R. John, Jr.
1989-01-01
The crash dynamics and energy absorption of composite sailplane fuselage segments undergoing nose-down impact were investigated. More than 10 quarter-scale structurally similar test articles, typical of high-performance sailplane designs, were tested. Fuselages segments were fabricated of combinations of fiberglass, graphite, Kevlar, and Spectra fabric materials. Quasistatic and dynamic tests were conducted. The quasistatic tests were found to replicate the strain history and failure modes observed in the dynamic tests. Failure modes of the quarter-scale model were qualitatively compared with full-scale crash evidence and quantitatively compared with current design criteria. By combining material and structural improvements, substantial increases in crashworthiness were demonstrated.
Experimental design methods for bioengineering applications.
Keskin Gündoğdu, Tuğba; Deniz, İrem; Çalışkan, Gülizar; Şahin, Erdem Sefa; Azbar, Nuri
2016-01-01
Experimental design is a form of process analysis in which certain factors are selected to obtain the desired responses of interest. It may also be used for the determination of the effects of various independent factors on a dependent factor. The bioengineering discipline includes many different areas of scientific interest, and each study area is affected and governed by many different factors. Briefly analyzing the important factors and selecting an experimental design for optimization are very effective tools for the design of any bioprocess under question. This review summarizes experimental design methods that can be used to investigate various factors relating to bioengineering processes. The experimental methods generally used in bioengineering are as follows: full factorial design, fractional factorial design, Plackett-Burman design, Taguchi design, Box-Behnken design and central composite design. These design methods are briefly introduced, and then the application of these design methods to study different bioengineering processes is analyzed.
A fast method for optical simulation of flood maps of light-sharing detector modules.
Shi, Han; Du, Dong; Xu, JianFeng; Moses, William W; Peng, Qiyu
2015-12-01
Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. We present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. While the two approaches generated comparable flood maps, the new approach was more than 200-600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.
75 FR 48672 - Pesticides; Revised Fee Schedule for Registration Applications
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-11
... follows B772 118 Amend or extend Experimental 3 11,577 Use Permit; minor changes to experimental design...,942 Experimental Use Permit; minor changes to experimental design; extend established temporary... revision of experimental design B780 121 New active ingredient; non- 12 144,704 food/feed; no SAP review...
Dasgupta, Annwesa P.; Anderson, Trevor R.
2014-01-01
It is essential to teach students about experimental design, as this facilitates their deeper understanding of how most biological knowledge was generated and gives them tools to perform their own investigations. Despite the importance of this area, surprisingly little is known about what students actually learn from designing biological experiments. In this paper, we describe a rubric for experimental design (RED) that can be used to measure knowledge of and diagnose difficulties with experimental design. The development and validation of the RED was informed by a literature review and empirical analysis of undergraduate biology students’ responses to three published assessments. Five areas of difficulty with experimental design were identified: the variable properties of an experimental subject; the manipulated variables; measurement of outcomes; accounting for variability; and the scope of inference appropriate for experimental findings. Our findings revealed that some difficulties, documented some 50 yr ago, still exist among our undergraduate students, while others remain poorly investigated. The RED shows great promise for diagnosing students’ experimental design knowledge in lecture settings, laboratory courses, research internships, and course-based undergraduate research experiences. It also shows potential for guiding the development and selection of assessment and instructional activities that foster experimental design. PMID:26086658
Experimental design for three-color and four-color gene expression microarrays.
Woo, Yong; Krueger, Winfried; Kaur, Anupinder; Churchill, Gary
2005-06-01
Three-color microarrays, compared with two-color microarrays, can increase design efficiency and power to detect differential expression without additional samples and arrays. Furthermore, three-color microarray technology is currently available at a reasonable cost. Despite the potential advantages, clear guidelines for designing and analyzing three-color experiments do not exist. We propose a three- and a four-color cyclic design (loop) and a complementary graphical representation to help design experiments that are balanced, efficient and robust to hybridization failures. In theory, three-color loop designs are more efficient than two-color loop designs. Experiments using both two- and three-color platforms were performed in parallel and their outputs were analyzed using linear mixed model analysis in R/MAANOVA. These results demonstrate that three-color experiments using the same number of samples (and fewer arrays) will perform as efficiently as two-color experiments. The improved efficiency of the design is somewhat offset by a reduced dynamic range and increased variability in the three-color experimental system. This result suggests that, with minor technological improvements, three-color microarrays using loop designs could detect differential expression more efficiently than two-color loop designs. http://www.jax.org/staff/churchill/labsite/software Multicolor cyclic design construction methods and examples along with additional results of the experiment are provided at http://www.jax.org/staff/churchill/labsite/pubs/yong.
NASA Astrophysics Data System (ADS)
khawaldeh, Salem A. Al
2013-07-01
Background and purpose: The purpose of this study was to investigate the comparative effects of a prediction/discussion-based learning cycle (HPD-LC), conceptual change text (CCT) and traditional instruction on 10th grade students' understanding of genetics concepts. Sample: Participants were 112 10th basic grade male students in three classes of the same school located in an urban area. The three classes taught by the same biology teacher were randomly assigned as a prediction/discussion-based learning cycle class (n = 39), conceptual change text class (n = 37) and traditional class (n = 36). Design and method: A quasi-experimental research design of pre-test-post-test non-equivalent control group was adopted. Participants completed the Genetics Concept Test as pre-test-post-test, to examine the effects of instructional strategies on their genetics understanding. Pre-test scores and Test of Logical Thinking scores were used as covariates. Results: The analysis of covariance showed a statistically significant difference between the experimental and control groups in the favor of experimental groups after treatment. However, no statistically significant difference between the experimental groups (HPD-LC versus CCT instruction) was found. Conclusions: Overall, the findings of this study support the use of the prediction/discussion-based learning cycle and conceptual change text in both research and teaching. The findings may be useful for improving classroom practices in teaching science concepts and for the development of suitable materials promoting students' understanding of science.
Pisano, Roberto; Fissore, Davide; Barresi, Antonello A; Brayard, Philippe; Chouvenc, Pierre; Woinet, Bertrand
2013-02-01
This paper shows how to optimize the primary drying phase, for both product quality and drying time, of a parenteral formulation via design space. A non-steady state model, parameterized with experimentally determined heat and mass transfer coefficients, is used to define the design space when the heat transfer coefficient varies with the position of the vial in the array. The calculations recognize both equipment and product constraints, and also take into account model parameter uncertainty. Examples are given of cycles designed for the same formulation, but varying the freezing conditions and the freeze-dryer scale. These are then compared in terms of drying time. Furthermore, the impact of inter-vial variability on design space, and therefore on the optimized cycle, is addressed. With this regard, a simplified method is presented for the cycle design, which reduces the experimental effort required for the system qualification. The use of mathematical modeling is demonstrated to be very effective not only for cycle development, but also for solving problem of process transfer. This study showed that inter-vial variability remains significant when vials are loaded on plastic trays, and how inter-vial variability can be taken into account during process design.
NASA Technical Reports Server (NTRS)
Barret, C.
1997-01-01
This publication presents the control requirements, the details of the designed Flight Control Augmentor's (FCA's), the static stability and dynamic stability wind tunnel test programs, the static stability and control analyses, the dynamic stability characteristics of the experimental Launch Vehicle (LV) with the designed FCA's, and a consideration of the elastic vehicle. Dramatic improvements in flight stability have been realized with all the FCA designs; these ranged from 41 percent to 72 percent achieved by the blunt TE design. The control analysis showed that control increased 110 percent with only 3 degrees of FCA deflection. The dynamic stability results showed improvements with all FCA designs tested at all Mach numbers tested. The blunt TE FCA's had the best overall dynamic stability results. Since the lowest elastic vehicle frequency must be well separated from that of the control system, the significant frequencies and modes of vibration have been identified, and the response spectra compared for the experimental LV in both the conventional and the aft cg configuration. Although the dynamic response was 150 percent greater in the aft cg configuration, the lowest bending mode frequency decreased by only 2.8 percent.
Cui, Fengjie; Zhao, Liming
2012-01-01
The objective of the study was to optimize the nutrition sources in a culture medium for the production of xylanase from Penicillium sp.WX-Z1 using Plackett-Burman design and Box-Behnken design. The Plackett-Burman multifactorial design was first employed to screen the important nutrient sources in the medium for xylanase production by Penicillium sp.WX-Z1 and subsequent use of the response surface methodology (RSM) was further optimized for xylanase production by Box-Behnken design. The important nutrient sources in the culture medium, identified by the initial screening method of Placket-Burman, were wheat bran, yeast extract, NaNO3, MgSO4, and CaCl2. The optimal amounts (in g/L) for maximum production of xylanase were: wheat bran, 32.8; yeast extract, 1.02; NaNO3, 12.71; MgSO4, 0.96; and CaCl2, 1.04. Using this statistical experimental design, the xylanase production under optimal condition reached 46.50 U/mL and an increase in xylanase activity of 1.34-fold was obtained compared with the original medium for fermentation carried out in a 30-L bioreactor. PMID:22949884
Cui, Fengjie; Zhao, Liming
2012-01-01
The objective of the study was to optimize the nutrition sources in a culture medium for the production of xylanase from Penicillium sp.WX-Z1 using Plackett-Burman design and Box-Behnken design. The Plackett-Burman multifactorial design was first employed to screen the important nutrient sources in the medium for xylanase production by Penicillium sp.WX-Z1 and subsequent use of the response surface methodology (RSM) was further optimized for xylanase production by Box-Behnken design. The important nutrient sources in the culture medium, identified by the initial screening method of Placket-Burman, were wheat bran, yeast extract, NaNO(3), MgSO(4), and CaCl(2). The optimal amounts (in g/L) for maximum production of xylanase were: wheat bran, 32.8; yeast extract, 1.02; NaNO(3), 12.71; MgSO(4), 0.96; and CaCl(2), 1.04. Using this statistical experimental design, the xylanase production under optimal condition reached 46.50 U/mL and an increase in xylanase activity of 1.34-fold was obtained compared with the original medium for fermentation carried out in a 30-L bioreactor.
On verifying magnetic dipole moment of a magnetic torquer by experiments
NASA Astrophysics Data System (ADS)
Kuyyakanont, Aekjira; Kuntanapreeda, Suwat; Fuengwarodsakul, Nisai H.
2018-01-01
Magnetic torquers are used for the attitude control of small satellites, such as CubeSats with Low Earth Orbit (LEO). During the design of magnetic torquers, it is necessary to confirm if its magnetic dipole moment is enough to control the satellite attitude. The magnetic dipole moment can affect the detumbling time and the satellite rotation time. In addition, it is also necessary to understand how to design the magnetic torquer for operation in a CubeSat under the space environment at LEO. This paper reports an investigation of the magnetic dipole moment and the magnetic field generated by a circular air-coil magnetic torquer using experimental measurements. The experiment testbed was built on an air-bearing under a magnetic field generated by a Helmholtz coil. This paper also describes the procedure to determine and verify the magnetic dipole moment value of the designed circular air-core magnetic torquer. The experimental results are compared with the design calculations. According to the comparison results, the designed magnetic torquer reaches the required magnetic dipole moment. This designed magnetic torquer will be applied to the attitude control systems of a 1U CubeSat satellite in the project “KNACKSAT.”
Adaptive design of visual perception experiments
NASA Astrophysics Data System (ADS)
O'Connor, John D.; Hixson, Jonathan; Thomas, James M., Jr.; Peterson, Matthew S.; Parasuraman, Raja
2010-04-01
Meticulous experimental design may not always prevent confounds from affecting experimental data acquired during visual perception experiments. Although experimental controls reduce the potential effects of foreseen sources of interference, interaction, or noise, they are not always adequate for preventing the confounding effects of unforeseen forces. Visual perception experimentation is vulnerable to unforeseen confounds because of the nature of the associated cognitive processes involved in the decision task. Some confounds are beyond the control of experimentation, such as what a participant does immediately prior to experimental participation, or the participant's attitude or emotional state. Other confounds may occur through ignorance of practical control methods on the part of the experiment's designer. The authors conducted experiments related to experimental fatigue and initially achieved significant results that were, upon re-examination, attributable to a lack of adequate controls. Re-examination of the original results and the processes and events that led to them yielded a second experimental design with more experimental controls and significantly different results. The authors propose that designers of visual perception experiments can benefit from planning to use a test-fix-test or adaptive experimental design cycle, so that unforeseen confounds in the initial design can be remedied.
Quasi experimental designs in pharmacist intervention research.
Krass, Ines
2016-06-01
Background In the field of pharmacist intervention research it is often difficult to conform to the rigorous requirements of the "true experimental" models, especially the requirement of randomization. When randomization is not feasible, a practice based researcher can choose from a range of "quasi-experimental designs" i.e., non-randomised and at time non controlled. Objective The aim of this article was to provide an overview of quasi-experimental designs, discuss their strengths and weaknesses and to investigate their application in pharmacist intervention research over the previous decade. Results In the literature quasi experimental studies may be classified into five broad categories: quasi-experimental design without control groups; quasi-experimental design that use control groups with no pre-test; quasi-experimental design that use control groups and pre-tests; interrupted time series and stepped wedge designs. Quasi-experimental study design has consistently featured in the evolution of pharmacist intervention research. The most commonly applied of all quasi experimental designs in the practice based research literature are the one group pre-post-test design and the non-equivalent control group design i.e., (untreated control group with dependent pre-tests and post-tests) and have been used to test the impact of pharmacist interventions in general medications management as well as in specific disease states. Conclusion Quasi experimental studies have a role to play as proof of concept, in the pilot phases of interventions when testing different intervention components, especially in complex interventions. They serve to develop an understanding of possible intervention effects: while in isolation they yield weak evidence of clinical efficacy, taken collectively, they help build a body of evidence in support of the value of pharmacist interventions across different practice settings and countries. However, when a traditional RCT is not feasible for logistical and/or ethical reasons researchers should endeavour to use the more robust of the quasi experimental designs.
An integrated computer-based procedure for teamwork in digital nuclear power plants.
Gao, Qin; Yu, Wenzhu; Jiang, Xiang; Song, Fei; Pan, Jiajie; Li, Zhizhong
2015-01-01
Computer-based procedures (CBPs) are expected to improve operator performance in nuclear power plants (NPPs), but they may reduce the openness of interaction between team members and harm teamwork consequently. To support teamwork in the main control room of an NPP, this study proposed a team-level integrated CBP that presents team members' operation status and execution histories to one another. Through a laboratory experiment, we compared the new integrated design and the existing individual CBP design. Sixty participants, randomly divided into twenty teams of three people each, were assigned to the two conditions to perform simulated emergency operating procedures. The results showed that compared with the existing CBP design, the integrated CBP reduced the effort of team communication and improved team transparency. The results suggest that this novel design is effective to optim team process, but its impact on the behavioural outcomes may be moderated by more factors, such as task duration. The study proposed and evaluated a team-level integrated computer-based procedure, which present team members' operation status and execution history to one another. The experimental results show that compared with the traditional procedure design, the integrated design reduces the effort of team communication and improves team transparency.
Integrating Reform-Oriented Math Instruction in Special Education Settings
ERIC Educational Resources Information Center
Bottge, Brian A.; Rueda, Enrique; LaRoque, Perry T.; Serlin, Ronald C.; Kwon, Jungmin
2007-01-01
This mixed-methods study assessed the effects of Enhanced Anchored Instruction (EAI) on the math performance of adolescents with learning disabilities in math (MLD). A quasi-experimental pretest-posttest control group design with switching replications was used to measure students' computation and problem-solving skills on EAI compared to control…
77 FR 40064 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-06
.... This study will use an experimental design to assess the effectiveness of two potential enhancements to... program directly or through contracts with states or private, non-profit entities. Reapproval of this... the Medicare Plan Finder to gain access to comparative plan information, and second that once the user...
Effects of a Math Intervention Program on Math Academic Performance among African American Students
ERIC Educational Resources Information Center
Johnson, Willie F., Jr.
2013-01-01
In the United States, an academic achievement gap has prevented many African American students from advancement and educational empowerment. Guided by Bandura's theoretical belief, which posits a relationship between social factors and an individual's perception, this non-experimental, causal comparative, control treatment group design study…
Enhancing Learning Outcomes through Evaluation of Serious Gaming: A Mixed Methods Study
ERIC Educational Resources Information Center
Douglas, Kerrie Anna
2012-01-01
This study compared the change in counseling student's self-efficacy and skill related to suicide assessment and intervention through the use of a novel intervention-oriented evaluation method, evaluation focused discussion groups, in an experimental embedded mixed methods design. An innovation counselor pedagogical tool, Suicide Risk Assessment…
The forces and moments on airplane engine mounts
NASA Technical Reports Server (NTRS)
Donely, Philip
1936-01-01
A resume of the equations and formulas for the forces and moments on an aircraft-engine mount is presented. In addition, available experimental data have been included to permit the computation of these forces and moments. A sample calculation is made and compared with present design conditions for engine mounts.
Who Needs Plants? Science (Experimental).
ERIC Educational Resources Information Center
Ropeik, Bernard H.; Kleinman, David Z.
The basic elective course in introductory botany is designed for secondary students who probably will not continue study in plant science. The objectives of the course are to help the student 1) identify, compare and differentiate types of plants; 2) identify plant cell structures; 3) distinguish between helpful and harmful plants; 4) predict…
Cognitive Therapy and Assertive Training in the Treatment of Depression in Women.
ERIC Educational Resources Information Center
LaPointe, Karen A.
Little empirical study has been done on the efficacy of the variety of psychological approaches used to treat depression. The author reviews theoretical points of view: psychoanalytic, cognitive and behavioral, and constructs an experimental design to compare the relative effectiveness of cognitive therapy, assertiveness training and insight…
2006-09-23
Roblee et al., 1958). Kubie (1988) derived a theoretical wall density function and compared it to experimental results. Reyes and Iglesia (1991) and...Engineering Chemistry Process Design and Development 7, 250-252. Kubie . J., 1988. Influence of containing walls on the distribution of voidage in
Improving Communicative Competence: Validation of a Social Skills Training Workshop.
ERIC Educational Resources Information Center
Dawson, Pamela J.; Spitzberg, Brian H.
The effectiveness of a social skills training workshop was assessed by comparing the rated competence of participants in an Interpersonal Skills Training Program to the rated competence of nonparticipants. Subjects' self-ratings were included. This comparison was operationalized through a pretest-posttest design with 12 experimental and 22 control…
Experimenter Confirmation Bias and the Correction of Science Misconceptions
ERIC Educational Resources Information Center
Allen, Michael; Coole, Hilary
2012-01-01
This paper describes a randomised educational experiment (n = 47) that examined two different teaching methods and compared their effectiveness at correcting one science misconception using a sample of trainee primary school teachers. The treatment was designed to promote engagement with the scientific concept by eliciting emotional responses from…
Management Education: An Experimental Course.
ERIC Educational Resources Information Center
Gutelius, Paul Payne
The thesis describes the design, implementation, and evaluation of a course in the theory and practice of management. It gives an appraisal of programmed learning techniques and compares three methods of teaching management--by readings, by cases, and by computer gaming. Additionally, it relates student reactions to the opportunity to select one…
Facilitating Family Group Inquiry at Science Museum Exhibits
ERIC Educational Resources Information Center
Gutwill, Joshua P.; Allen, Sue
2010-01-01
We describe a study of programs to deepen families' scientific inquiry practices in a science museum setting. The programs incorporated research-based learning principles from formal and informal educational environments. In a randomized experimental design, two versions of the programs, called "inquiry games," were compared to two control…
A laboratory-scale experimental program was designed to standardize each of four black carbon measurement methods, provide appropriate quality assurance/control procedures for these techniques, and compare measurements made by these methods to a NIST traceable standard (filter gr...
Major Re-Selection Advising and Academic Performance
ERIC Educational Resources Information Center
McKenzie, Deborah; Tan, Tony Xing; Fletcher, Edward C.; Jackson-Williams, Andrea
2017-01-01
We sought to determine whether receiving major re-selection (MRS) advising benefits undergraduate students' grade-point averages (GPAs). We used a quasi-experimental nonequivalent control group design to compare a treatment group (n = 219) of undergraduates who changed their majors after receiving MRS advising with a control group (n = 206) who…
Supporting Executive Functions during Children's Preliteracy Learning with the Computer
ERIC Educational Resources Information Center
Van de Sande, E.; Segers, E.; Verhoeven, L.
2016-01-01
The present study examined how embedded activities to support executive functions helped children to benefit from a computer intervention that targeted preliteracy skills. Three intervention groups were compared on their preliteracy gains in a randomized controlled trial design: an experimental group that worked with software to stimulate early…
Simulation and the Development of Clinical Judgment: A Quantitative Study
ERIC Educational Resources Information Center
Holland, Susan
2015-01-01
The purpose of this quantitative pretest posttest quasi-experimental research study was to explore the effect of the NESD on clinical judgment in associate degree nursing students and compare the differences between groups when the Nursing Education Simulation Design (NESD) guided simulation in order to identify educational strategies promoting…
Schizophrenia and Crisis Theory.
ERIC Educational Resources Information Center
Mosher, Loren R.; And Others
An experimental two-year treatment project designed to help the acute schizophrenic emerge from psychosis a stronger, better integrated person is underway at Soteria House, a comfortable 16-room house in the San Francisco Bay area. The project will compare the effects of treatment in this special facility with those of "usual" treatment in a…
Relation between experimental and non-experimental study designs. HB vaccines: a case study
Jefferson, T.; Demicheli, V.
1999-01-01
STUDY OBJECTIVE: To examine the relation between experimental and non- experimental study design in vaccinology. DESIGN: Assessment of each study design's capability of testing four aspects of vaccine performance, namely immunogenicity (the capacity to stimulate the immune system), duration of immunity conferred, incidence and seriousness of side effects, and number of infections prevented by vaccination. SETTING: Experimental and non-experimental studies on hepatitis B (HB) vaccines in the Cochrane Vaccines Field Database. RESULTS: Experimental and non-experimental vaccine study designs are frequently complementary but some aspects of vaccine quality can only be assessed by one of the types of study. More work needs to be done on the relation between study quality and its significance in terms of effect size. PMID:10326054
Development of a NEW Vector Magnetograph at Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
West, Edward; Hagyard, Mona; Gary, Allen; Smith, James; Adams, Mitzi; Rose, M. Franklin (Technical Monitor)
2001-01-01
This paper will describe the Experimental Vector Magnetograph that has been developed at the Marshall Space Flight Center (MSFC). This instrument was designed to improve linear polarization measurements by replacing electro-optic and rotating waveplate modulators with a rotating linear analyzer. Our paper will describe the motivation for developing this magnetograph, compare this instrument with traditional magnetograph designs, and present a comparison of the data acquired by this instrument and original MSFC vector magnetograph.
Development of a Cross-Flow Fan Rotor for Vertical Take-Off and Landing Aircraft
2013-06-01
ANSYS CFX , along with the commercial computer-aided design software SolidWorks, was used to model and perform a parametric study on the number of rotor...the results found using ANSYS CFX . The experimental and analytical models were successfully compared at speeds ranging from 4,000 to 7,000 RPM...will make vertical take-off possible. The commercial computational fluid dynamics software ANSYS CFX , along with the commercial computer-aided design
ERIC Educational Resources Information Center
Moeyaert, Mariola; Ugille, Maaike; Ferron, John M.; Onghena, Patrick; Heyvaert, Mieke; Beretvas, S. Natasha; Van den Noortgate, Wim
2015-01-01
The purpose of this study is to illustrate the multilevel meta-analysis of results from single-subject experimental designs of different types, including AB phase designs, multiple-baseline designs, ABAB reversal designs, and alternating treatment designs. Current methodological work on the meta-analysis of single-subject experimental designs…
NASA Astrophysics Data System (ADS)
Sakarya, Doǧan Uǧur
2017-10-01
Beam steering optical arrangement needs less volume envelope for same field of regard than other gimbal approaches. Both for imaging and four quadrant missile applications, volume is critical parameter limiting system performance. Therefore, a conceptual design of beam steering method has been focused on both imaging and four quadrant missiles. In this study; four different optical designs have been made by using both beam steering and regular method for mid-wave infra-red imaging and four quadrant systems. Optical designs performances have been illustrated in simulation results. By using manufactured Risley prisms, some experimental results are conducted to compare simulations results.
Schramm, Sébastien; Vailhen, Dominique; Bridoux, Maxime Cyril
2016-02-12
A method for the sensitive quantification of trace amounts of organic explosives in water samples was developed by using stir bar sorptive extraction (SBSE) followed by liquid desorption and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The proposed method was developed and optimized using a statistical design of experiment approach. Use of experimental designs allowed a complete study of 10 factors and 8 analytes including nitro-aromatics, amino-nitro-aromatics and nitric esters. The liquid desorption study was performed using a full factorial experimental design followed by a kinetic study. Four different variables were tested here: the liquid desorption mode (stirring or sonication), the chemical nature of the stir bar (PDMS or PDMS-PEG), the composition of the liquid desorption phase and finally, the volume of solvent used for the liquid desorption. On the other hand, the SBSE extraction study was performed using a Doehlert design. SBSE extraction conditions such as extraction time profiles, sample volume, modifier addition, and acetic acid addition were examined. After optimization of the experimental parameters, sensitivity was improved by a factor 5-30, depending on the compound studied, due to the enrichment factors reached using the SBSE method. Limits of detection were in the ng/L level for all analytes studied. Reproducibility of the extraction with different stir bars was close to the reproducibility of the analytical method (RSD between 4 and 16%). Extractions in various water sample matrices (spring, mineral and underground water) have shown similar enrichment compared to ultrapure water, revealing very low matrix effects. Copyright © 2016 Elsevier B.V. All rights reserved.
Sanchez, Gaëtan; Lecaignard, Françoise; Otman, Anatole; Maby, Emmanuel; Mattout, Jérémie
2016-01-01
The relatively young field of Brain-Computer Interfaces has promoted the use of electrophysiology and neuroimaging in real-time. In the meantime, cognitive neuroscience studies, which make extensive use of functional exploration techniques, have evolved toward model-based experiments and fine hypothesis testing protocols. Although these two developments are mostly unrelated, we argue that, brought together, they may trigger an important shift in the way experimental paradigms are being designed, which should prove fruitful to both endeavors. This change simply consists in using real-time neuroimaging in order to optimize advanced neurocognitive hypothesis testing. We refer to this new approach as the instantiation of an Active SAmpling Protocol (ASAP). As opposed to classical (static) experimental protocols, ASAP implements online model comparison, enabling the optimization of design parameters (e.g., stimuli) during the course of data acquisition. This follows the well-known principle of sequential hypothesis testing. What is radically new, however, is our ability to perform online processing of the huge amount of complex data that brain imaging techniques provide. This is all the more relevant at a time when physiological and psychological processes are beginning to be approached using more realistic, generative models which may be difficult to tease apart empirically. Based upon Bayesian inference, ASAP proposes a generic and principled way to optimize experimental design adaptively. In this perspective paper, we summarize the main steps in ASAP. Using synthetic data we illustrate its superiority in selecting the right perceptual model compared to a classical design. Finally, we briefly discuss its future potential for basic and clinical neuroscience as well as some remaining challenges.
Teacher content knowledge in the context of science education reform
NASA Astrophysics Data System (ADS)
Doby, Janice Kay
1997-12-01
The decline of science education in elementary schools has been well documented. While numerous efforts have been made for the purpose of reforming science education, most of those efforts have targeted science programs, assessment techniques, and setting national, state, and local standards, stressing teacher accountability for meeting those standards. However, inadequate science content knowledge of preservice teachers limits their ability to master effective teaching strategies, and also may foster negative attitudes toward science and science teaching. It is, therefore, highly unlikely that any significant reform in science education will be realized until this major underlying problem is addressed and resolved. The purpose of this study was to examine the effects of an experimental elementary science methods course, which employs the use of laser videodisc technology and instructional implications from cognitive science and instructional design, in terms of preservice teacher gains in Earth and physical science content knowledge and locus of control in science. The experimental elementary science methods course was compared to a more traditional approach to the same course which focused primarily on methods of teaching in the physical sciences and other science domains. The experimental and traditional groups were compared before and after treatment in terms of preservice teachers' content knowledge in Earth and physical science and locus ofcontrol in science. Results indicated that the experimental and traditional groups were comparable prior to treatment. The experimental group (89 preservice teachers) responded correctly to 45% of the items on the Elementary Science Concepts Test (ESCT) pretest and the traditional group (78 preservice teachers) responded correctly to 42% of the pretest items, the difference between groups being nonsignificant. Further, the experimental and traditional groups scored similarly on the pre-assessment of locus of control in science with scores on the Preservice Teacher Information and Science Opinion Questionnaire (ISOQ) of 162.12 and 163.65, respectively, the difference also being nonsignificant. The pre- and post-administrations of both the ESCT and ISOQ were all found to be statistically significant (F (4, 162) = 271.18343, p<0.05) in predicting group membership. Analyses of variance indicated significantly greater gains in Earth and physical science content knowledge (F (1,165) = 743.7746, p<0.025) and locus of control in science (F (1,165) = 45.7477, p<0.025) for the experimental group compared to the traditional group. A significant difference (F = (2,162) = 31.82279, p<0.05) was found between the combined effect of locus of control in science and Earth and physical science content knowledge in respect to treatment, indicating that the curriculum and instructional design of the experimental course significantly influenced preservice teachers' science content knowledge and locus of control in science. Suggestions for further research included: (a) determining whether the results of this present research may also apply to inservice teachers, (b) determining the effects of such preservice and inservice training on actual classroom practice, (c) relating increased science knowledge with improvement in science lesson planning and mastery of pedagogical skills, and (d) more detailed analysis of instructional implications from cognitive science and instructional design in regard to their application to the teaching of science (as well as other content areas).
Experimental Test Rig for Optimal Control of Flexible Space Robotic Arms
2016-12-01
was used to refine the test bed design and the experimental workflow. Three concepts incorporated various strategies to design a robust flexible link...used to refine the test bed design and the experimental workflow. Three concepts incorporated various strategies to design a robust flexible link... designed to perform the experimentation . The first and second concepts use traditional elastic springs in varying configurations while a third uses a
Schweizer, Marin L; Braun, Barbara I; Milstone, Aaron M
2016-10-01
Quasi-experimental studies evaluate the association between an intervention and an outcome using experiments in which the intervention is not randomly assigned. Quasi-experimental studies are often used to evaluate rapid responses to outbreaks or other patient safety problems requiring prompt, nonrandomized interventions. Quasi-experimental studies can be categorized into 3 major types: interrupted time-series designs, designs with control groups, and designs without control groups. This methods paper highlights key considerations for quasi-experimental studies in healthcare epidemiology and antimicrobial stewardship, including study design and analytic approaches to avoid selection bias and other common pitfalls of quasi-experimental studies. Infect Control Hosp Epidemiol 2016;1-6.
Schweizer, Marin L.; Braun, Barbara I.; Milstone, Aaron M.
2016-01-01
Quasi-experimental studies evaluate the association between an intervention and an outcome using experiments in which the intervention is not randomly assigned. Quasi-experimental studies are often used to evaluate rapid responses to outbreaks or other patient safety problems requiring prompt non-randomized interventions. Quasi-experimental studies can be categorized into three major types: interrupted time series designs, designs with control groups, and designs without control groups. This methods paper highlights key considerations for quasi-experimental studies in healthcare epidemiology and antimicrobial stewardship including study design and analytic approaches to avoid selection bias and other common pitfalls of quasi-experimental studies. PMID:27267457
Markert, Ronald J; O'Neill, Sally C; Bhatia, Subhash C
2003-01-01
The objectives of continuing medical education (CME) programs include knowledge acquisition, skill development, clinical reasoning and decision making, and health care outcomes. We conducted a year-long medical education research study in which knowledge acquisition in our CME programs was assessed. A randomized separate-sample pretest/past-test design, a quasi-experimental technique, was used. Nine CME programs with a sufficient number of participants were identified a priori. Knowledge acquisition was compared between the control group and the intervention group for the nine individual programs and for the combined programs. A total of 667 physicians, nurses, and other health professionals participated. Significant gain in knowledge was found for six programs: Perinatology, Pain Management, Fertility Care 2, Pediatrics, Colorectal Diseases, and Alzheimer's Disease (each p < .001). Also, the intervention group differed from the control group when the nine programs were combined (p < .001), with an effect size of .84. The use of sound quasi-experimental research methodology (separate-sample pretest/post-test design), the inclusion of a representative sample of CME programs, and the analysis of nearly 700 subjects led us to have confidence in concluding that our CME participants acquired a meaningful amount of new knowledge.
NASA Technical Reports Server (NTRS)
Berry, S. A.
1986-01-01
An incompressible boundary-layer stability analysis of Laminar Flow Control (LFC) experimental data was completed and the results are presented. This analysis was undertaken for three reasons: to study laminar boundary-layer stability on a modern swept LFC airfoil; to calculate incompressible design limits of linear stability theory as applied to a modern airfoil at high subsonic speeds; and to verify the use of linear stability theory as a design tool. The experimental data were taken from the slotted LFC experiment recently completed in the NASA Langley 8-Foot Transonic Pressure Tunnel. Linear stability theory was applied and the results were compared with transition data to arrive at correlated n-factors. Results of the analysis showed that for the configuration and cases studied, Tollmien-Schlichting (TS) amplification was the dominating disturbance influencing transition. For these cases, incompressible linear stability theory correlated with an n-factor for TS waves of approximately 10 at transition. The n-factor method correlated rather consistently to this value despite a number of non-ideal conditions which indicates the method is useful as a design tool for advanced laminar flow airfoils.
NASA Astrophysics Data System (ADS)
Beck, Joakim; Dia, Ben Mansour; Espath, Luis F. R.; Long, Quan; Tempone, Raúl
2018-06-01
In calculating expected information gain in optimal Bayesian experimental design, the computation of the inner loop in the classical double-loop Monte Carlo requires a large number of samples and suffers from underflow if the number of samples is small. These drawbacks can be avoided by using an importance sampling approach. We present a computationally efficient method for optimal Bayesian experimental design that introduces importance sampling based on the Laplace method to the inner loop. We derive the optimal values for the method parameters in which the average computational cost is minimized according to the desired error tolerance. We use three numerical examples to demonstrate the computational efficiency of our method compared with the classical double-loop Monte Carlo, and a more recent single-loop Monte Carlo method that uses the Laplace method as an approximation of the return value of the inner loop. The first example is a scalar problem that is linear in the uncertain parameter. The second example is a nonlinear scalar problem. The third example deals with the optimal sensor placement for an electrical impedance tomography experiment to recover the fiber orientation in laminate composites.
Performance of Oil Pumping Rings: An Analytical and Experimental Study
NASA Technical Reports Server (NTRS)
Eusepi, M. W.; Walowit, J. A.; Pinkus, O.; Holmes, P.
1986-01-01
A steady-state design computer program was developed to predict the performance of pumping rings as functions of geometry, applied loading, speed, ring modulus, and fluid viscosity. Additional analyses were developed to predict transient behavior of the ring and the effects of temperature rises occurring in the hydrodynamic film between the ring and shaft. The analysis was initially compared with previous experimental data and then used to design additional rings for further testing. Tests were performed with Rulon, carbon-graphite, and babbit rings. The design analysis was used to size all of the rings and to select the ranges of clearances, thickness, and loading. Although full quantitative agreement was lacking, relative agreement existed in that rings that were predicted to perform well theoretically, generally performed well experimentally. Some causes for discrepanices between theory and experiment are believed to be due to starvation, leakage past the secondary seal at high pressures, and uncertainties in the small clearances and local inlet temperatures to the pumping ring. A separate preliminary analysis was performed for a pumping Leningrader seal. This anlaysis can be used to predict the film thickness and flow rate thr ough the seal as a function of pressure, speed, loading, and geometry.
The in vivo wear resistance of 12 composite resins.
Lang, B R; Bloem, T J; Powers, J M; Wang, R F
1992-09-01
The in vivo wear resistance of 12 composite resins were compared with an amalgam control using the Latin Square experimental design. Sixteen edentulous patients wearing specially designed complete dentures formed the experimental population. The Michigan Computer Graphics Measurement System was used to digitize the surface of the control and composite resin samples before and after 3-month test periods to obtain wear data. The 12 composite resins selected for this investigation based on their published composite classification types were seven fine particle composites, three blends, and two microfilled composite resins. The Latin Square experimental design was found to be valid with the factor of material being statistically different at the 5% level of significance. Wear was computed as volume loss (mm3/mm2), and all of the composites studied had more wear than the amalgam control (P = .001). After 3 months, the mean (error) of wear of the amalgam was 0.028 (0.006). Means (error) of wear for the 12 composites were ranked from most to least wear by mean wear volume loss. The absence of any relationship between mean wear volume loss and the volume percentage filler was confirmed by the correlation coefficient r = -0.158.
A Customized Intervention for Dementia Caregivers: A Quasi-Experimental Design.
Wawrziczny, Emilie; Larochette, Clotilde; Papo, David; Constant, Emilie; Ducharme, Francine; Kergoat, Marie-Jeanne; Pasquier, Florence; Antoine, Pascal
2018-04-01
The aim of this study is to test the effects of a customized intervention on distress among caregivers of persons with dementia (PWD) using a quasi-experimental design. Fifty-one spouse caregivers in the experimental group and 51 in the control group participated in the study. The effects of the intervention were examined by comparing caregivers' responses with questionnaires at pre-intervention baseline (T0) and immediately after intervention (T1). Differences were quantified using repeated-measures ANOVA. The analyses indicated a stabilizing effect of the intervention on caregivers' perceptions of PWD's daily functioning, self-esteem related to caregiving, quality of family support, and feeling of distress. Linear increases were observed regarding sense of preparedness and impact on daily routine, while no differences (interaction and linear effects) were observed for degree of self-efficacy, depression, impact on finances, or self-rated health. These findings show a preliminary efficacy of the intervention proposed in this study to prevent the exacerbation of caregivers' distress.
Wang, Jiale; Alves, Tiago V; Trindade, Fabiane J; de Aquino, Caroline B; Pieretti, Joana C; Domingues, Sergio H; Ando, Romulo A; Ornellas, Fernando R; Camargo, Pedro H C
2015-11-23
By a combination of theoretical and experimental design, we probed the effect of a quasi-single electron on the surface plasmon resonance (SPR)-mediated catalytic activities of Ag nanoparticles. Specifically, we started by theoretically investigating how the E-field distribution around the surface of a Ag nanosphere was influenced by static electric field induced by one, two, or three extra fixed electrons embedded in graphene oxide (GO) next to the Ag nanosphere. We found that the presence of the extra electron(s) changed the E-field distributions and led to higher electric field intensities. Then, we experimentally observed that a quasi-single electron trapped at the interface between GO and Ag NPs in Ag NPs supported on graphene oxide (GO-Ag NPs) led to higher catalytic activities as compared to Ag and GO-Ag NPs without electrons trapped at the interface, representing the first observation of catalytic enhancement promoted by a quasi-single electron. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gu, Wenwen; Chen, Ying; Li, Yu
2017-08-01
Based on the experimental subcooled liquid vapor pressures (P L ) of 17 polychlorinated naphthalene (PCN) congeners, one type of three-dimensional quantitative structure-activity relationship (3D-QSAR) models, comparative molecular similarity indices analysis (CoMSIA), was constructed with Sybyl software. Full factor experimental design was used to obtain the final regulation scheme for PCN, and then carry out modification of PCN-2 to significantly lower its P L . The contour maps of CoMSIA model showed that the migration ability of PCN decreases when the Cl atoms at the 2-, 3-, 4-, 5-, 6-, 7- and 8-positions of PCNs are replaced by electropositive groups. After modification of PCN-2, 12 types of new modified PCN-2 compounds were obtained with lnP L values two orders of magnitude lower than that of PCN-2. In addition, there are significant differences between the calculated total energies and energy gaps of the new modified compounds and those of PCN-2.
Modelling short time series in metabolomics: a functional data analysis approach.
Montana, Giovanni; Berk, Maurice; Ebbels, Tim
2011-01-01
Metabolomics is the study of the complement of small molecule metabolites in cells, biofluids and tissues. Many metabolomic experiments are designed to compare changes observed over time under two or more experimental conditions (e.g. a control and drug-treated group), thus producing time course data. Models from traditional time series analysis are often unsuitable because, by design, only very few time points are available and there are a high number of missing values. We propose a functional data analysis approach for modelling short time series arising in metabolomic studies which overcomes these obstacles. Our model assumes that each observed time series is a smooth random curve, and we propose a statistical approach for inferring this curve from repeated measurements taken on the experimental units. A test statistic for detecting differences between temporal profiles associated with two experimental conditions is then presented. The methodology has been applied to NMR spectroscopy data collected in a pre-clinical toxicology study.
NASA Astrophysics Data System (ADS)
Xiao, Deli; Zhang, Chan; He, Jia; Zeng, Rong; Chen, Rong; He, Hua
2016-12-01
Simple, accurate and high-throughput pretreatment method would facilitate large-scale studies of trace analysis in complex samples. Magnetic mixed hemimicelles solid-phase extraction has the power to become a key pretreatment method in biological, environmental and clinical research. However, lacking of experimental predictability and unsharpness of extraction mechanism limit the development of this promising method. Herein, this work tries to establish theoretical-based experimental designs for extraction of trace analytes from complex samples using magnetic mixed hemimicelles solid-phase extraction. We selected three categories and six sub-types of compounds for systematic comparative study of extraction mechanism, and comprehensively illustrated the roles of different force (hydrophobic interaction, π-π stacking interactions, hydrogen-bonding interaction, electrostatic interaction) for the first time. What’s more, the application guidelines for supporting materials, surfactants and sample matrix were also summarized. The extraction mechanism and platform established in the study render its future promising for foreseeable and efficient pretreatment under theoretical based experimental design for trace analytes from environmental, biological and clinical samples.
Design and experimental investigations on six-stroke SI engine using acetylene with water injection.
Gupta, Keshav; Suthar, Kishanlal; Jain, Sheetal Kumar; Agarwal, Ghanshyam Das; Nayyar, Ashish
2018-06-02
In the present study, a four-stroke cycle gasoline engine is redesigned and converted into a six-stroke cycle engine and experimental study has been conducted using gasoline and acetylene as fuel with water injection at the end of the recompression stroke. Acetylene has been used as an alternative fuel along with gasoline and performance of the six-stroke spark ignition (SI) engine with these two fuels has been studied separately and compared. Brake power and thermal efficiency are found to be 5.18 and 1.55% higher with acetylene as compared to gasoline in the six-stroke engine. However, thermal efficiency is found to be 45% higher with acetylene in the six-stroke engine as compared to four-stroke SI engine. The CO and HC emissions were found to be reduced by 13.33 and 0.67% respectively with acetylene as compared to gasoline due to better combustion of acetylene. The NO x emission was reduced by 5.65% with acetylene due to lower peak temperature by water injection. The experimental results showed better engine performance and emissions with acetylene as fuel in the six-stroke engine.
A new pooling strategy for high-throughput screening: the Shifted Transversal Design
Thierry-Mieg, Nicolas
2006-01-01
Background In binary high-throughput screening projects where the goal is the identification of low-frequency events, beyond the obvious issue of efficiency, false positives and false negatives are a major concern. Pooling constitutes a natural solution: it reduces the number of tests, while providing critical duplication of the individual experiments, thereby correcting for experimental noise. The main difficulty consists in designing the pools in a manner that is both efficient and robust: few pools should be necessary to correct the errors and identify the positives, yet the experiment should not be too vulnerable to biological shakiness. For example, some information should still be obtained even if there are slightly more positives or errors than expected. This is known as the group testing problem, or pooling problem. Results In this paper, we present a new non-adaptive combinatorial pooling design: the "shifted transversal design" (STD). It relies on arithmetics, and rests on two intuitive ideas: minimizing the co-occurrence of objects, and constructing pools of constant-sized intersections. We prove that it allows unambiguous decoding of noisy experimental observations. This design is highly flexible, and can be tailored to function robustly in a wide range of experimental settings (i.e., numbers of objects, fractions of positives, and expected error-rates). Furthermore, we show that our design compares favorably, in terms of efficiency, to the previously described non-adaptive combinatorial pooling designs. Conclusion This method is currently being validated by field-testing in the context of yeast-two-hybrid interactome mapping, in collaboration with Marc Vidal's lab at the Dana Farber Cancer Institute. Many similar projects could benefit from using the Shifted Transversal Design. PMID:16423300
Enhanced sensitivity of CpG island search and primer design based on predicted CpG island position.
Park, Hyun-Chul; Ahn, Eu-Ree; Jung, Ju Yeon; Park, Ji-Hye; Lee, Jee Won; Lim, Si-Keun; Kim, Won
2018-05-01
DNA methylation has important biological roles, such as gene expression regulation, as well as practical applications in forensics, such as in body fluid identification and age estimation. DNA methylation often occurs in the CpG site, and methylation within the CpG islands affects various cellular functions and is related to tissue-specific identification. Several programs have been developed to identify CpG islands; however, the size, location, and number of predicted CpG islands are not identical due to different search algorithms. In addition, they only provide structural information for predicted CpG islands without experimental information, such as primer design. We developed an analysis pipeline package, CpGPNP, to integrate CpG island prediction and primer design. CpGPNP predicts CpG islands more accurately and sensitively than other programs, and designs primers easily based on the predicted CpG island locations. The primer design function included standard, bisulfite, and methylation-specific PCR to identify the methylation of particular CpG sites. In this study, we performed CpG island prediction on all chromosomes and compared CpG island search performance of CpGPNP with other CpG island prediction programs. In addition, we compared the position of primers designed for a specific region within the predicted CpG island using other bisulfite PCR primer programs. The primers designed by CpGPNP were used to experimentally verify the amplification of the target region of markers for body fluid identification and age estimation. CpGPNP is freely available at http://forensicdna.kr/cpgpnp/. Copyright © 2018 Elsevier B.V. All rights reserved.
Seismic design repair and retrofit strategies for steel roof deck diaphragms
NASA Astrophysics Data System (ADS)
Franquet, John-Edward
Structural engineers will often rely on the roof diaphragm to transfer lateral seismic loads to the bracing system of single-storey structures. The implementation of capacity-based design in the NBCC 2005 has caused an increase in the diaphragm design load due to the need to use the probable capacity of the bracing system, thus resulting in thicker decks, closer connector patterns and higher construction costs. Previous studies have shown that accounting for the in-plane flexibility of the diaphragm when calculating the overall building period can result in lower seismic forces and a more cost-efficient design. However, recent studies estimating the fundamental period of single storey structures using ambient vibration testing showed that the in-situ approximation was much shorter than that obtained using analytical means. The difference lies partially in the diaphragm stiffness characteristics which have been shown to decrease under increasing excitation amplitude. Using the diaphragm as the energy-dissipating element in the seismic force resisting system has also been investigated as this would take advantage of the diaphragm's ductility and limited overstrength; thus, lower capacity based seismic forces would result. An experimental program on 21.0m by 7.31m diaphragm test specimens was carried out so as to investigate the dynamic properties of diaphragms including the stiffness, ductility and capacity. The specimens consisted of 20 and 22 gauge panels with nailed frame fasteners and screwed sidelap connections as well a welded and button-punch specimen. Repair strategies for diaphragms that have previously undergone inelastic deformations were devised in an attempt to restitute the original stiffness and strength and were then experimentally evaluated. Strength and stiffness experimental estimations are compared with those predicted with the Steel Deck Institute (SDI) method. A building design comparative study was also completed. This study looks at the difference in design and cost yielded by previous and current design practice with EBF braced frames. Two alternate design methodologies, where the period is not restricted by code limitations and where the diaphragm force is limited to the equivalent shear force calculated with RdR o = 1.95, are also used for comparison. This study highlights the importance of incorporating the diaphragm stiffness in design and the potential cost savings.
ERIC Educational Resources Information Center
Castro, Ruben
2010-01-01
This study evaluated the effectiveness of Total Physical Response Storytelling (TPRS[TM]) compared to the Grammar-Translation approach for acquiring and retaining new vocabulary in an English as a Second Language (ESL) class. The subjects were adult Hispanic learners with limited literacy. An experimental design approach was used to gather…
Optimizing Experimental Designs: Finding Hidden Treasure.
USDA-ARS?s Scientific Manuscript database
Classical experimental design theory, the predominant treatment in most textbooks, promotes the use of blocking designs for control of spatial variability in field studies and other situations in which there is significant variation among heterogeneity among experimental units. Many blocking design...
How scientific experiments are designed: Problem solving in a knowledge-rich, error-rich environment
NASA Astrophysics Data System (ADS)
Baker, Lisa M.
While theory formation and the relation between theory and data has been investigated in many studies of scientific reasoning, researchers have focused less attention on reasoning about experimental design, even though the experimental design process makes up a large part of real-world scientists' reasoning. The goal of this thesis was to provide a cognitive account of the scientific experimental design process by analyzing experimental design as problem-solving behavior (Newell & Simon, 1972). Three specific issues were addressed: the effect of potential error on experimental design strategies, the role of prior knowledge in experimental design, and the effect of characteristics of the space of alternate hypotheses on alternate hypothesis testing. A two-pronged in vivo/in vitro research methodology was employed, in which transcripts of real-world scientific laboratory meetings were analyzed as well as undergraduate science and non-science majors' design of biology experiments in the psychology laboratory. It was found that scientists use a specific strategy to deal with the possibility of error in experimental findings: they include "known" control conditions in their experimental designs both to determine whether error is occurring and to identify sources of error. The known controls strategy had not been reported in earlier studies with science-like tasks, in which participants' responses to error had consisted of replicating experiments and discounting results. With respect to prior knowledge: scientists and undergraduate students drew on several types of knowledge when designing experiments, including theoretical knowledge, domain-specific knowledge of experimental techniques, and domain-general knowledge of experimental design strategies. Finally, undergraduate science students generated and tested alternates to their favored hypotheses when the space of alternate hypotheses was constrained and searchable. This result may help explain findings of confirmation bias in earlier studies using science-like tasks, in which characteristics of the alternate hypothesis space may have made it unfeasible for participants to generate and test alternate hypotheses. In general, scientists and science undergraduates were found to engage in a systematic experimental design process that responded to salient features of the problem environment, including the constant potential for experimental error, availability of alternate hypotheses, and access to both theoretical knowledge and knowledge of experimental techniques.
Development of high temperature acoustic emission sensing system using fiber Bragg grating
NASA Astrophysics Data System (ADS)
Pang, Dandan; Sui, Qingmei; Wang, Ming; Guo, Dongmei; Sai, Yaozhang
2018-03-01
In some applications in structural health monitoring (SHM), the acoustic emission (AE) detection technology is used in the high temperature environment. In this paper, a high-temperature-resistant AE sensing system is developed based on the fiber Bragg grating (FBG) sensor. A novel high temperature FBG AE sensor is designed with a high signal-to-noise ratio (SNR) compared with the traditional FBG AE sensor. The output responses of the designed sensors with different sensing fiber lengths also are investigated both theoretically and experimentally. Excellent AE detection results are obtained using the proposed FBG AE sensing system over a temperature range from 25 ° to 200 °. The experimental results indicate that this FBG AE sensing system can well meet the application requirement in AE detecting areas at high temperature.
Cousineau, Justine Emily; Bennion, Kevin S.; Chieduko, Victor; ...
2018-05-08
Cooling of electric machines is a key to increasing power density and improving reliability. This paper focuses on the design of a machine using a cooling jacket wrapped around the stator. The thermal contact resistance (TCR) between the electric machine stator and cooling jacket is a significant factor in overall performance and is not well characterized. This interface is typically an interference fit subject to compressive pressure exceeding 5 MPa. An experimental investigation of this interface was carried out using a thermal transmittance setup using pressures between 5 and 10 MPa. Furthermore, the results were compared to currently available modelsmore » for contact resistance, and one model was adapted for prediction of TCR in future motor designs.« less
The Modern Design of Experiments for Configuration Aerodynamics: A Case Study
NASA Technical Reports Server (NTRS)
DeLoach, Richard
2006-01-01
The effects of slowly varying and persisting covariate effects on the accuracy and precision of experimental result is reviewed, as is the rationale for run-order randomization as a quality assurance tactic employed in the Modern Design of Experiments (MDOE) to defend against such effects. Considerable analytical complexity is introduced by restrictions on randomization in configuration aerodynamics tests because they involve hard-to-change configuration variables that cannot be randomized conveniently. Tradeoffs are examined between quality and productivity associated with varying degrees of rigor in accounting for such randomization restrictions. Certain characteristics of a configuration aerodynamics test are considered that may justify a relaxed accounting for randomization restrictions to achieve a significant reduction in analytical complexity with a comparably negligible adverse impact on the validity of the experimental results.
NASA Astrophysics Data System (ADS)
Witter, A. E.; Klinger, D. M.; Fan, X.; Lam, M.; Mathers, D. T.; Mabury, S. A.
2002-10-01
The forensic analysis of cocaine on currencies was optimized using a fractional, two-level experimental design that compared methanol and HCl extraction, SPE versus heptane pre-concentration, and extracted versus total ion chromatography. Subsequent student-initiated questions about levels of cocaine on U.S. and world currencies helped make connections to societal issues while teaching method optimization and chromatography. A significant correlation was found between the levels of cocaine and the age of the bills. Levels of cocaine on various world currencies followed expected drug-trafficking patterns with the highest levels found in the most developed countries.
Robust independent modal space control of a coupled nano-positioning piezo-stage
NASA Astrophysics Data System (ADS)
Zhu, Wei; Yang, Fufeng; Rui, Xiaoting
2018-06-01
In order to accurately control a coupled 3-DOF nano-positioning piezo-stage, this paper designs a hybrid controller. In this controller, a hysteresis observer based on a Bouc-Wen model is established to compensate the hysteresis nonlinearity of the piezoelectric actuator first. Compared to hysteresis compensations using Preisach model and Prandt-Ishlinskii model, the compensation method using the hysteresis observer is computationally lighter. Then, based on the proposed dynamics model, by constructing the modal filter, a robust H∞ independent modal space controller is designed and utilized to decouple the piezo-stage and deal with the unmodeled dynamics, disturbance, and hysteresis compensation error. The effectiveness of the proposed controller is demonstrated experimentally. The experimental results show that the proposed controller can significantly achieve the high-precision positioning.
On the design and optimisation of new fractal antenna using PSO
NASA Astrophysics Data System (ADS)
Rani, Shweta; Singh, A. P.
2013-10-01
An optimisation technique for newly shaped fractal structure using particle swarm optimisation with curve fitting is presented in this article. The aim of particle swarm optimisation is to find the geometry of the antenna for the required user-defined frequency. To assess the effectiveness of the presented method, a set of representative numerical simulations have been done and the results are compared with the measurements from experimental prototypes built according to the design specifications coming from the optimisation procedure. The proposed fractal antenna resonates at the 5.8 GHz industrial, scientific and medical band which is suitable for wireless telemedicine applications. The antenna characteristics have been studied using extensive numerical simulations and are experimentally verified. The antenna exhibits well-defined radiation patterns over the band.