ERIC Educational Resources Information Center
Shih, Ching-Hsiang
2011-01-01
The latest researches have adopted software technology turning the gyration air mouse into a high performance limb movement detector, and have assessed whether two persons with multiple disabilities would be able to control an environmental stimulation using limb movement. This study extends gyration air mouse functionality by actively reducing…
ERIC Educational Resources Information Center
Shih, Ching-Hsiang; Yeh, Jui-Chi; Shih, Ching-Tien; Chang, Man-Ling
2011-01-01
The latest studies have adopted software technology which turns the Wii Remote Controller into a high-performance limb action detector, we assessed whether two persons with multiple disabilities would be able to control an environmental stimulus through limb action. This study extends the functionality of the Wii Remote Controller to the…
Shih, Ching-Hsiang; Yeh, Jui-Chi; Shih, Ching-Tien; Chang, Man-Ling
2011-01-01
The latest studies have adopted software technology which turns the Wii Remote Controller into a high-performance limb action detector, we assessed whether two persons with multiple disabilities would be able to control an environmental stimulus through limb action. This study extends the functionality of the Wii Remote Controller to the correction of limb hyperactive behavior to assess whether two children with Attention Deficit Hyperactivity Disorder (ADHD) would be able to actively reduce their limb hyperactive behavior through controlling their favorite stimuli by turning them on/off using a Wii Remote Controller. An ABAB design, in which A represented the baseline and B represented intervention phases, was adopted in this study. Result showed that both participants significantly increased their time duration of maintaining a static limb posture (TDMSLP) to activate the control system in order to produce environmental stimulation in the intervention phases. Practical and developmental implications of the findings are discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.
Shih, Ching-Hsiang
2011-01-01
The latest researches have adopted software technology turning the gyration air mouse into a high performance limb movement detector, and have assessed whether two persons with multiple disabilities would be able to control an environmental stimulation using limb movement. This study extends gyration air mouse functionality by actively reducing limb hyperactive behavior to assess whether two persons with attention deficit hyperactivity disorder (ADHD) would be able to actively reduce their limb hyperactive behavior by controlling their favorite stimulation on/off using a gyration air mouse with a newly developed actively limb hyperactive behavior reducing program (ALHBRP). The study was performed according to an ABAB design, in which A represented the baseline and B represented intervention phases. Data showed that both participants significantly increased their time duration of maintaining a static limb posture (TDMSLP) to activate the control system in order to produce environmental stimulation during the intervention phases. Practical and developmental implications of the findings are discussed. Copyright © 2010 Elsevier Ltd. All rights reserved.
Future developments in brain-machine interface research.
Lebedev, Mikhail A; Tate, Andrew J; Hanson, Timothy L; Li, Zheng; O'Doherty, Joseph E; Winans, Jesse A; Ifft, Peter J; Zhuang, Katie Z; Fitzsimmons, Nathan A; Schwarz, David A; Fuller, Andrew M; An, Je Hi; Nicolelis, Miguel A L
2011-01-01
Neuroprosthetic devices based on brain-machine interface technology hold promise for the restoration of body mobility in patients suffering from devastating motor deficits caused by brain injury, neurologic diseases and limb loss. During the last decade, considerable progress has been achieved in this multidisciplinary research, mainly in the brain-machine interface that enacts upper-limb functionality. However, a considerable number of problems need to be resolved before fully functional limb neuroprostheses can be built. To move towards developing neuroprosthetic devices for humans, brain-machine interface research has to address a number of issues related to improving the quality of neuronal recordings, achieving stable, long-term performance, and extending the brain-machine interface approach to a broad range of motor and sensory functions. Here, we review the future steps that are part of the strategic plan of the Duke University Center for Neuroengineering, and its partners, the Brazilian National Institute of Brain-Machine Interfaces and the École Polytechnique Fédérale de Lausanne (EPFL) Center for Neuroprosthetics, to bring this new technology to clinical fruition.
Future developments in brain-machine interface research
Lebedev, Mikhail A; Tate, Andrew J; Hanson, Timothy L; Li, Zheng; O'Doherty, Joseph E; Winans, Jesse A; Ifft, Peter J; Zhuang, Katie Z; Fitzsimmons, Nathan A; Schwarz, David A; Fuller, Andrew M; An, Je Hi; Nicolelis, Miguel A L
2011-01-01
Neuroprosthetic devices based on brain-machine interface technology hold promise for the restoration of body mobility in patients suffering from devastating motor deficits caused by brain injury, neurologic diseases and limb loss. During the last decade, considerable progress has been achieved in this multidisciplinary research, mainly in the brain-machine interface that enacts upper-limb functionality. However, a considerable number of problems need to be resolved before fully functional limb neuroprostheses can be built. To move towards developing neuroprosthetic devices for humans, brain-machine interface research has to address a number of issues related to improving the quality of neuronal recordings, achieving stable, long-term performance, and extending the brain-machine interface approach to a broad range of motor and sensory functions. Here, we review the future steps that are part of the strategic plan of the Duke University Center for Neuroengineering, and its partners, the Brazilian National Institute of Brain-Machine Interfaces and the École Polytechnique Fédérale de Lausanne (EPFL) Center for Neuroprosthetics, to bring this new technology to clinical fruition. PMID:21779720
Nycz, Christopher J; Delph, Michael A; Fischer, Gregory S
2015-01-01
Robotic technology has recently been explored as a means to rehabilitate and assist individuals suffering from hemiparesis of their upper limbs. Robotic approaches allow for targeted rehabilitation routines which are more personalized and adaptable while providing quantitative measurements of patient outcomes. Development of these technologies into inherently safe and portable devices has the potential to extend the therapy outside of the clinical setting and into the patient's home with benefits to the cost and accessibility of care. To this end, a soft, cable actuated robotic glove and sleeve was designed, modeled, and constructed to provide assistance of finger and elbow movements in a way that mimics the biological function of the tendons. The resulting design increases safety through greater compliance as well as greater tolerance for misalignment with the user's skeletal frame over traditional rigid exoskeletons. Overall this design provides a platform to expand and study the concepts around soft robotic rehabilitation.
ERIC Educational Resources Information Center
Shih, Ching-Hsiang; Shih, Chia-Ju; Shih, Ching-Tien
2011-01-01
The latest researches have adopted software technology by applying the Nintendo Wii Remote Controller to the correction of hyperactive limb behavior. This study extended Wii Remote Controller functionality for improper head position (posture) correction (i.e. actively adjusting abnormal head posture) to assess whether two people with multiple…
Novel dry cryotherapy system for cooling the equine digit
Stefanovski, Darko; Lenfest, Margret; Chatterjee, Sraboni; Orsini, James
2018-01-01
Objectives Digital cryotherapy is commonly used for laminitis prophylaxis and treatment. Currently validated methods for distal limb cryotherapy involve wet application or compression technology. There is a need for a practical, affordable, dry cryotherapy method that effectively cools the digit. The objective of this study was to evaluate the hoof wall surface temperatures (HWSTs) achieved with a novel dry cryotherapy technology. Design Repeated-measures in vivo experimental study. Setting Experimental intervention at a single site. Participants 6 systemically healthy horses (3 mares, 3 geldings). Interventions Cryotherapy was applied to six horses for eight hours with a commercially available rubber and rubber and welded fabricice boot, which extended proximally to include the foot and pastern. Reusable malleable cold therapy packs were secured against the foot and pastern with the three built-in hook-and-loop fastener panels. Primary and secondary outcome measures HWST and pastern surface temperature of the cryotherapy-treated limb, HWST of the control limb and ambient temperature were recorded every five minutes throughout the study period. Results Results were analysed with mixed-effects multivariable regression analysis. The HWST (median 11.1°C, interquartile range 8.6°C–14.7°C) in the cryotherapy-treated limb was significantly decreased compared with the control limb (median 29.7°C, interquartile range 28.9°C–30.4°C) (P≤0.001). Cryotherapy limb HWST reached a minimum of 6.75°C (median) with an interquartile range of 4.1°C–9.3°C. Minimum HWST was achieved 68 minutes after cryotherapy pack application. Conclusions Dry application of cryotherapy significantly reduced HWST and reached minimums below the therapeutic target of 10°C. This cryotherapy method might offer an effective alternative for digital cooling. PMID:29344364
Low-Cost Methodology for Skin Strain Measurement of a Flexed Biological Limb.
Lin, Bevin; Moerman, Kevin M; McMahan, Connor G; Pasch, Kenneth A; Herr, Hugh M
2017-12-01
The purpose of this manuscript is to compute skin strain data from a flexed biological limb, using portable, inexpensive, and easily available resources. We apply and evaluate this approach on a person with bilateral transtibial amputations, imaging left and right residual limbs in extended and flexed knee postures. We map 3-D deformations to a flexed biological limb using freeware and a simple point-and-shoot camera. Mean principal strain, maximum shear strain, as well as lines of maximum, minimum, and nonextension are computed from 3-D digital models to inform directional mappings of the strain field for an unloaded residual limb. Peak tensile strains are ∼0.3 on the anterior surface of the knee in the proximal region of the patella, whereas peak compressive strains are ∼ -0.5 on the posterior surface of the knee. Peak maximum shear strains are ∼0.3 on the posterior surface of the knee. The accuracy and precision of this methodology are assessed for a ground-truth model. The mean point location distance is found to be 0.08 cm, and the overall standard deviation for point location difference vectors is 0.05 cm. This low-cost and mobile methodology may prove critical for applications such as the prosthetic socket interface where whole-limb skin strain data are required from patients in the field outside of traditional, large-scale clinical centers. Such data may inform the design of wearable technologies that directly interface with human skin.
Upper extremity prosthesis user perspectives on unmet needs and innovative technology.
Benz, Heather L; Jia Yao; Rose, Laura; Olgac, Okan; Kreutz, Karen; Saha, Anindita; Civillico, Eugene F
2016-08-01
The needs of individuals with upper limb amputation and congenital limb difference are not being fully met by current prostheses, as evidenced by prosthesis rejection, non-wear, and user reports of pain and challenging activities. Emerging technologies such as dexterous sensorized robotic limbs, osseointegrated prostheses, implantable EMG electrodes, and electrical stimulation for sensory feedback have the potential to address unmet needs, but pose additional risks. We plan to assess upper limb prosthesis user needs and perspectives on these new benefits and risks using an extensive quantitative survey. In preparation for this survey, we report here on qualitative interviews with seven individuals with upper limb amputation or congenital limb difference. Unstructured text was mined using topic modeling and the results compared with identified themes. A more complete understanding of how novel technologies could address real user concerns will inform implementation of new technologies and regulatory decision-making.
Upper Extremity Prosthesis User Perspectives on Unmet Needs and Innovative Technology
Benz, Heather L.; Yao, Jia; Rose, Laura; Olgac, Okan; Kreutz, Karen; Saha, Anindita; Civillico, Eugene F.
2017-01-01
The needs of individuals with upper limb amputation and congenital limb difference are not being fully met by current prostheses, as evidenced by prosthesis rejection, non-wear, and user reports of pain and challenging activities. Emerging technologies such as dexterous sensorized robotic limbs, osseointegrated prostheses, implantable EMG electrodes, and electrical stimulation for sensory feedback have the potential to address unmet needs, but pose additional risks. We plan to assess upper limb prosthesis user needs and perspectives on these new benefits and risks using an extensive quantitative survey. In preparation for this survey, we report here on qualitative interviews with seven individuals with upper limb amputation or congenital limb difference. Unstructured text was mined using topic modeling and the results compared with identified themes. A more complete understanding of how novel technologies could address real user concerns will inform implementation of new technologies and regulatory decision-making. PMID:28268333
The Role of Spatially Controlled Cell Proliferation in Limb Bud Morphogenesis
Boehm, Bernd; Westerberg, Henrik; Lesnicar-Pucko, Gaja; Raja, Sahdia; Rautschka, Michael; Cotterell, James; Swoger, Jim; Sharpe, James
2010-01-01
Although the vertebrate limb bud has been studied for decades as a model system for spatial pattern formation and cell specification, the cellular basis of its distally oriented elongation has been a relatively neglected topic by comparison. The conventional view is that a gradient of isotropic proliferation exists along the limb, with high proliferation rates at the distal tip and lower rates towards the body, and that this gradient is the driving force behind outgrowth. Here we test this hypothesis by combining quantitative empirical data sets with computer modelling to assess the potential role of spatially controlled proliferation rates in the process of directional limb bud outgrowth. In particular, we generate two new empirical data sets for the mouse hind limb—a numerical description of shape change and a quantitative 3D map of cell cycle times—and combine these with a new 3D finite element model of tissue growth. By developing a parameter optimization approach (which explores spatial patterns of tissue growth) our computer simulations reveal that the observed distribution of proliferation rates plays no significant role in controlling the distally extending limb shape, and suggests that directional cell activities are likely to be the driving force behind limb bud outgrowth. This theoretical prediction prompted us to search for evidence of directional cell orientations in the limb bud mesenchyme, and we thus discovered a striking highly branched and extended cell shape composed of dynamically extending and retracting filopodia, a distally oriented bias in Golgi position, and also a bias in the orientation of cell division. We therefore provide both theoretical and empirical evidence that limb bud elongation is achieved by directional cell activities, rather than a PD gradient of proliferation rates. PMID:20644711
Environmental monitoring for the DOE coolside and LIMB demonstration extension projects
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, T.; Contos, L.; Adams, L.
1992-03-01
The purpose of this document is to present environmental monitoring data collected during the US Department of Energy Limestone Injection Multistage Burner (DOE LIMB) Demonstration Project Extension at the Ohio Edison Edgewater Generating Station in Lorain, Ohio. The DOE project is an extension of the US Environmental Protection Agency's (EPA's) original LIMB Demonstration. The program is operated nuclear DOE's Clean Coal Technology Program of emerging clean coal technologies'' under the categories of in boiler control of oxides of sulfur and nitrogen'' as well as post-combustion clean-up.'' The objective of the LIMB program is to demonstrate the sulfur dioxide (SO{sub 2})more » and nitrogen oxide (NO{sub x}) emission reduction capabilities of the LIMB system. The LIMB system is a retrofit technology to be used for existing coal-fired boilers equipped with electrostatic precipitators (ESPs).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, T.; Contos, L.; Adams, L.
1992-03-01
The purpose of this document is to present environmental monitoring data collected during the US Department of Energy Limestone Injection Multistage Burner (DOE LIMB) Demonstration Project Extension at the Ohio Edison Edgewater Generating Station in Lorain, Ohio. The DOE project is an extension of the US Environmental Protection Agency`s (EPA`s) original LIMB Demonstration. The program is operated nuclear DOE`s Clean Coal Technology Program of ``emerging clean coal technologies`` under the categories of ``in boiler control of oxides of sulfur and nitrogen`` as well as ``post-combustion clean-up.`` The objective of the LIMB program is to demonstrate the sulfur dioxide (SO{sub 2})more » and nitrogen oxide (NO{sub x}) emission reduction capabilities of the LIMB system. The LIMB system is a retrofit technology to be used for existing coal-fired boilers equipped with electrostatic precipitators (ESPs).« less
Burgess, M Loring; Schmitt, Daniel; Zeininger, Angel; McFarlin, Shannon C; Zihlman, Adrienne L; Polk, John D; Ruff, Christopher B
2016-09-01
Previous studies suggest that the postures habitually adopted by an animal influence the mechanical loading of its long bones. Relatively extended limb postures in larger animals should preferentially reduce anteroposterior (A-P) relative to mediolateral (M-L) bending of the limb bones and therefore decrease A-P/M-L rigidity. We test this hypothesis by examining growth-related changes in limb bone structure in two primate taxa that differ in ontogenetic patterns of joint posture. Knee and elbow angles of adult and immature vervets (Chlorocebus aethiops, n = 16) were compared to published data for baboons (Papio hamadryas ursinus, n = 33, Patel et al., ). Ontogenetic changes in ratios of A-P/M-L bending rigidity in the femur and humerus were compared in skeletal samples (C. aethiops, n = 28; P. cynocephalus, n = 39). Size changes were assessed with linear regression, and age group differences tested with ANOVA. Only the knee of baboons shows significant postural change, becoming more extended with age and mass. A-P/M-L bending rigidity of the femur decreases during ontogeny in immature and adult female baboons only. Trends in the humerus are less marked. Adult male baboons have higher A-P/M-L bending rigidity of the femur than females. The hypothesized relationship between more extended joints and reduced A-P/M-L bending rigidity is supported by our results for immature and adult female baboon hind limbs, and the lack of significant age changes in either parameter in forelimbs and vervets. Adult males of both species depart from general ontogenetic trends, possibly due to socially mediated behavioral differences between sexes. Am J Phys Anthropol 161:72-83, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Maiden flight of the infrared sounder GLORIA
NASA Astrophysics Data System (ADS)
Friedl-Vallon, Felix; Gloria-Team
2013-05-01
The Gimballed Limb Radiance Imager of the Atmosphere (GLORIA) instrument is an imaging Fourier transform spectrometer that is capable to operate on various high altitude research aircraft and on stratospheric balloons. The instrument is a joint development of the Helmholtz Centers Jülich and Karlsruhe Institute of Technology. GLORIA has flown for the first time in December 2011 on board the Russian Geophysica M55 research aircraft. Atmospheric measurements with GLORIA are possible in limb and nadir geometry. The scientific focus in limb sounding mode is on dynamics, tropopause region, TTL and polar UTLS. The nadir mode is tailored to processes in the troposphere such as biomass burning events and high precision methane measurements. The combination of limb and nadir will combine good spatial resolution in both the troposphere and lower stratosphere. In addition, GLORIA serves as a proof of concept instrument for the candidate ESA Earth explorer mission PREMIER. The GLORIA spectrometer consists of a classical Michelson interferometer combined with an infrared camera. The spectral range of the first instrument version extends from 780 cm-1 to 1400 cm-1 with a spectral resolution of up to 0.075 cm-1. The high speed HgCdTe focal plane array with 256×256 elements allows in the limb mode an extremely high spatial sampling of up to 100 m in the vertical domain. The spectrometer is mounted in a gimballed frame that permits agility in elevational and azimuthal direction, as well as image rotation. Scene acquisition and scene stabilisation are accomplished by a control system based on an inertial measurement unit. Limb scenes can be chosen within 45° and 132° to the flight direction of the aircraft allowing tomographic analysis of sampled air volumes.
Development of a 3-D Rehabilitation System for Upper Limbs Using ER Actuators in a Nedo Project
NASA Astrophysics Data System (ADS)
Furusho, Junji; Koyanagi, Ken'ichi; Nakanishi, Kazuhiko; Ryu, Ushio; Takenaka, Shigekazu; Inoue, Akio; Domen, Kazuhisa; Miyakoshi, Koichi
New training methods and exercises for upper limbs rehabilitation are made possible by application of robotics and virtual reality technology. The technologies can also make quantitative evaluations and enhance the qualitative effect of training. We have joined a project managed by NEDO (New Energy and Industrial Technology Development Organization as a semi-governmental organization under the Ministry of Economy, Trade and Industry of Japan) 5-year Project, "Rehabilitation System for the Upper Limbs and Lower Limbs", and developed a 3-DOF exercise machine for upper limbs (EMUL) using ER actuators. In this paper, we also present the development of software for motion exercise trainings and some results of clinical evaluation. Moreover, it is discussed how ER actuators ensure the mechanical safety.
Prosthetics and Related Technology
... of prostheses, using leading- edge technologies such as robotics, tissue engineering, and nanotechnology to create lighter limbs ... Investigating different care strategies for residual limbs after surgery, which may improve understanding of wound care in ...
Application of Comparative Functional Genomics to Identify Regeneration-Specific Genes
2014-08-25
The first objective will extend an ongoing study of the transcriptional basis of limb regeneration in the Mexican axolotl (Ambystoma mexicanum) to...Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 Limb Regeneration, Transcriptome, Salamander, Axolotl REPORT...transcriptional basis of limb regeneration in the Mexican axolotl (Ambystoma mexicanum) to three additional salamander species (A. tigrinum, A. maculatum, and
The report gives results of the full-scale demonstration of Limestone Injection Multistage Burner (LIMB) technology on the coal-fired, 105 MW, Unit 4 boiler at Ohio Edison's Edgewater Station. eveloped as a technology aimed at moderate levels of sulfur dioxide (SO2) and nitrogen ...
A Mobile Motion Analysis System Using Intertial Sensors for Analysis of Lower Limb Prosthetics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mueller, John Kyle P; Ericson, Milton Nance; Farquhar, Ethan
Soldiers returning from the global war on terror requiring lower leg prosthetics generally have different concerns and requirements than the typical lower leg amputee. These subjects are usually young, wish to remain active and often desire to return to active military duty. As such, they demand higher performance from their prosthetics, but are at risk for chronic injury and joint conditions in their unaffected limb. Motion analysis is a valuable tool in assessing the performance of new and existing prosthetic technologies as well as the methods in fitting these devices to both maximize performance and minimize risk of injury formore » the individual soldier. We are developing a mobile, low-cost motion analysis system using inertial measurement units (IMUs) and two custom force sensors that detect ground reaction forces and moments on both the unaffected limb and prosthesis. IMUs were tested on a robot programmed to simulate human gait motion. An algorithm which uses a kinematic model of the robot and an extended Kalman filter (EKF) was used to convert the rates and accelerations from the gyro and accelerometer into joint angles. Compared to encoder data from the robot, which was considered the ground truth in this experiment, the inertial measurement system had a RMSE of <1.0 degree. Collecting kinematic and kinetic data without the restrictions and expense of a motion analysis lab could help researchers, designers and prosthetists advance prosthesis technology and customize devices for individuals. Ultimately, these improvements will result in better prosthetic performance for the military population.« less
Method and apparatus for simulating gravitational forces on a living organism
NASA Technical Reports Server (NTRS)
Thornton, W. E. (Inventor)
1983-01-01
A method and apparatus for simulating gravitational forces on a living organism wherein a series of negative pressures are externally applied to successive length-wise sections of a lower limb of the organism. The pressures decreasing progressively with distance of said limb sections from the heart of the organism. A casing defines a chamber adapted to contain the limb of the organism and is rigidified to resist collapse upon the application of negative pressures to the interior of the chamber. Seals extend inwardly from the casing for effective engagement with the limb of the organism and, in cooperation with the limb, subdivide the chamber into a plurality of compartments each in negative pressure communicating relation with the limb.
Vertical distribution of Martian aerosols from SPICAM/Mars-Express limb observations
NASA Astrophysics Data System (ADS)
Fedorova, A.; Korablev, O.; Bertaux, J.-L.; Rodin, A.; Perrier, S.; Moroz, V. I.
Limb spectroscopic observations provide invaluable information about vertical distribution of main atmospheric components in the Martian atmosphere, in particular vertical distribution and structure of aerosols, which play an important role in the heat balance of the planet. Only limited set of successful limb spectroscopic observations have been carried out on Mars so far, including those by MGS/TES spectrometer and Thermoscan and Auguste experiments of Phobos mission. Currently SPICAM instrument onboard Mars-Express spacecraft has accomplished several sequences of limb observations. First analysis of limb sounding data received by SPICAM IR and UV channels, which imply the presence of fine, deep, optically thin aerosol fraction extended over broad range of altitudes, is presented.
Red-cockaded woodpecker foraging behavior
D. Craig Rudolph; Richard N. Conner; Richard R. Schaefer; Nancy E. Koerth
2007-01-01
We studied Red-cockaded Woodpeckers (Picoides borealis) to examine the effect of status and gender on foraging behavior. Foraging behavior of breeding pairs extended beyond separation by foraging height to include zones (bole, trunk in crown, primary limb, secondary limb) of the tree used and foraging methods (scaling, probing, excavating). Helper...
Braithwaite, Irene; Mackintosh, Stephen; Buchanan, Samantha; Schwarzenlander, Kerstin; De Ruyter, Bernadette
2017-02-01
We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. Randomized controlled trial. Twenty-four healthy participants aged 18-54 had both feet placed within the Jet Impulse Technology system and were randomised for one or other leg to be within a below-knee fibreglass cast. Pacific Radiology, Lower Hutt, Wellington. The primary outcome variable was peak systolic velocity (cm/s) compared between legs with and without the cast at 60 min (after 10 min Jet Impulse Technology activation), using a mixed linear model and a non-inferiority bound of 4.8 cm/s. Secondary outcome variables were the difference in peak systolic velocity between the casted limb and the non-casted limb at baseline and 40 min after casting, and the difference in mean flow velocity (cm/s), vein diameter (mm), and total volume flow (L/min) between the casted limb and the non-casted limb at baseline, 40 and 60 min. The mean (standard deviation) peak systolic velocity was 4.6(1.5), 4.8(1.1), 28.8(16.1), and 4.3(1.2), 4.8(1.4) and 29.3(19.0) cm/s at baseline, 40 and 60 min in the casted and non-casted leg, respectively. The difference (95% confidence interval) between cast and no-cast at 60 min was -0.8 (-6.5 to 4.9) cm/s, P = 0.78. The peak systolic velocity, flow velocity and total volume flow at 40 min were not statistically significantly different from baseline for both casted and non-casted limb. In healthy volunteers, the popliteal venous haemodynamics of the Jet Impulse Technology system was similar between the legs with and without a below-knee fibreglass cast. In-cast Jet Impulse Technology may provide a non-pharmacological option for venous thromboembolism prophylaxis for lower-limb cast-immobility.
Exploring the fine structure at the limb in coronal holes
NASA Technical Reports Server (NTRS)
Karovska, Magarita; Blundell, Solon F.; Habbal, Shadia Rifai
1994-01-01
The fine structure of the solar limb in coronal holes is explored at temperatures ranging from 10(exp 4) to 10(exp 6) K. An image enhancement algorithm orignally developed for solar eclipse observations is applied to a number of simultaneous multiwavelength observations made with the Harvard Extreme Ultraviolet Spectrometer experiment on Skylab. The enhanced images reveal the presence of filamentary structures above the limb with a characteristic separation of approximately 10 to 15 sec . Some of the structures extend from the solar limb into the corona to at least 4 min above the solar limb. The brightness of these structures changes as a function of height above the limb. The brightest emission is associated with spiculelike structures in the proximity of the limb. The emission characteristic of high-temperature plasma is not cospatial with the emission at lower temperatures, indicating the presence of different temperature plasmas in the field of view.
Development of upper limb prostheses: current progress and areas for growth.
González-Fernández, Marlís
2014-06-01
Upper extremity prosthetic technology has significantly changed in recent years. The devices available and those under development are more and more able to approximate the function of the lost limb; however, other challenges remain. This article provides a brief perspective on the most advanced upper limb prostheses available and the challenges present for continued development of the technology. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Technology that Touches Lives: Teleconsultation to Benefit Persons with Upper Limb Loss
Whelan, Lynsay R.; Wagner, Nathan
2011-01-01
While over 1.5 million individuals are living with limb loss in the United States (Ziegler-Graham et al., 2008), only 10% of these individuals have a loss that affects an upper limb. Coincident with the relatively low incidence of upper limb loss, is a shortage of the community-based prosthetic rehabilitation experts that can help prosthetic users to more fully integrate their devices into their daily routines. This article describes how expert prosthetists and occupational therapists at Touch Bionics, a manufacturer of advanced upper limb prosthetic devices, employ Voice over the Internet Protocol (VoIP) videoconferencing software telehealth technologies to engage in remote consultation with users of prosthetic devices and/or their local practitioners. The Touch Bionics staff provide follow-up expertise to local prosthetists, occupational therapists, and other health professionals. Contrasted with prior telephone-based consultations, the video-enabled approach provides enhanced capabilities to benefit persons with upper limb loss. Currently, the opportunities for Touch Bionics occupational therapists to fully engage in patient-based services delivered through telehealth technologies are significantly reduced by their need to obtain and maintain professional licenses in multiple states. PMID:25945186
The use of prostheses in skeletally immature patients.
Abudu, Adesegun; Grimer, Robert; Tillman, Roger; Carter, Simon
2006-01-01
Prosthetic reconstruction in the skeletally immature patient is challenging because of the necessity to cope with expected disruption of limb growth after resection of one or more major growth plates and the high demands placed on implants by young patients. Although prosthetic reconstruction in children is fraught with many problems, it is usually possible to obtain a good functional limb at skeletal maturity. Extendable prostheses are readily acceptable to patients and their parents. The availability of noninvasive extendable prostheses is expected to lead to fewer complications, fewer surgical interventions, and even improved function. This article reviews the indication, evolution, and clinical and functional results of extendable endoprostheses, drawing from experience in the last 30 years of using such prostheses in children.
The report summarizes activities conducted and results achieved in an EPA-sponsored program to demonstrate Limestone Injection Multistage Burner (LIMB) technology on a tangentially fired coal-burning utility boiler, Virginia Power's 180-MWe Yorktown Unit No. 2. his successfully d...
Environmental monitoring for the DOE coolside and LIMB demonstration extension projects
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, T.; Contos, L.; Adams, L.
1992-02-01
The purpose of this document is to present environmental monitoring data collected during the US DOE Limestone Injection Multistage Burner (LIMB) Demonstration Project Extension. The objective of the LIMB program is to demonstrate the sulfur dioxide (SO{sub 2}) and nitrogen oxide (NO{sub x}) emission reduction capabilities of the LIMB system. The LIMB system is a retrofit technology to be used for existing coal-fired boilers equipped with electrostatic precipitators. (VC)
Code of Federal Regulations, 2012 CFR
2012-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2010 CFR
2010-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2013 CFR
2013-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2011 CFR
2011-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2014 CFR
2014-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Ahmed, Altayeb Abdalla
2016-09-01
Identification of a deceased individual is an essential component of medicolegal practice. However, personal identification based on commingled limbs or parts of limbs, necessary in investigations of mass disasters or some crimes, is a difficult task. Limb measurements have been utilized in the development of biological parameters for personal identification, but the possibility to estimate the dimensions of parts of limbs other than hands and feet has not been assessed. The present study proposes an approach to estimate the dimensions of various parts of limbs based on other limb measurements. The study included 320 Sudanese adults, with equal representation of men and women. Nine limb dimensions were measured (five based on the upper limb, four based on the lower limb), and extensive statistical analysis of the distribution of values was performed. The results showed that all of the measured dimensions were sexually dimorphic and that there was a significant positive correlation between the dimensions of various parts of limbs. Regression models (direct and stepwise) were developed to estimate the dimensions of parts of limbs based on measurements pertaining to one or more other parts of limbs. The study revealed that the dimensions of parts of the upper and lower limb can be estimated from one another. These findings can be used in medicolegal practice and extended to constructive surgery, orthopedics, and prosthesis design for lost limbs.
Endlein, Thomas; Ji, Aihong; Samuel, Diana; Yao, Ning; Wang, Zhongyuan; Barnes, W. Jon P.; Federle, Walter; Kappl, Michael; Dai, Zhendong
2013-01-01
To live and clamber about in an arboreal habitat, tree frogs have evolved adhesive pads on their toes. In addition, they often have long and slender legs to facilitate not only long jumps, but also to bridge gaps between leaves when climbing. Both adhesive pads and long limbs are used in conjunction, as we will show in this study. Previous research has shown that tree frogs change from a crouched posture (where the limbs are close to the body) to a sprawled posture with extended limbs when clinging on to steeper inclines such as vertical or overhanging slopes. We investigated this change in posture in White's tree frogs (Litoria caerulea) by challenging the frogs to cling onto a tiltable platform. The platform consisted of an array of 24 three-dimensional force transducers, which allowed us to measure the ground reaction forces of the frogs during a tilt. Starting from a crouched resting position, the normal forces on the forelimbs changed sign and became increasingly negative with increasing slope angle of the platform. At about 106°±12°, tilt of the platform the frogs reacted by extending one or two of their limbs outwards. At a steeper angle (131°±11°), the frogs spread out all their limbs sideways, with the hindlimbs stretched out to their maximum reach. Although the extension was strongest in the lateral direction, limbs were significantly extended in the fore–aft direction as well. With the extension of the limbs, the lateral forces increased relative to the normal forces. The large contribution of the in-plane forces helped to keep the angle between the force vector and the platform small. The Kendall theory for the peeling of adhesive tape predicts that smaller peel angles lead to higher attachment forces. We compare our data with the predictions of the Kendall model and discuss possible implications of the sliding of the pads on the surface. The forces were indeed much larger for smaller angles and thus can be explained by peeling theory. PMID:23325755
ENGINEERING APPLICATION AND ECONOMICS OF LIMB (LIMESTONE INJECTION/MULTISTAGE BURNERS)
The paper describes the use of an EPA LIMB cost model, in conjunction with cost and performance models for flue gas desulfurization (FGD), to compare these two technologies under similar premises. (NOTE: The performance goals of LIMB, EPA's acronym for Limestone Injection/Multist...
Mackintosh, Stephen; Buchanan, Samantha; Schwarzenlander, Kerstin; De Ruyter, Bernadette
2017-01-01
Objectives We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. Design Randomized controlled trial. Participants Twenty-four healthy participants aged 18–54 had both feet placed within the Jet Impulse Technology system and were randomised for one or other leg to be within a below-knee fibreglass cast. Setting Pacific Radiology, Lower Hutt, Wellington Main outcome measures The primary outcome variable was peak systolic velocity (cm/s) compared between legs with and without the cast at 60 min (after 10 min Jet Impulse Technology activation), using a mixed linear model and a non-inferiority bound of 4.8 cm/s. Secondary outcome variables were the difference in peak systolic velocity between the casted limb and the non-casted limb at baseline and 40 min after casting, and the difference in mean flow velocity (cm/s), vein diameter (mm), and total volume flow (L/min) between the casted limb and the non-casted limb at baseline, 40 and 60 min. Results The mean (standard deviation) peak systolic velocity was 4.6(1.5), 4.8(1.1), 28.8(16.1), and 4.3(1.2), 4.8(1.4) and 29.3(19.0) cm/s at baseline, 40 and 60 min in the casted and non-casted leg, respectively. The difference (95% confidence interval) between cast and no-cast at 60 min was −0.8 (−6.5 to 4.9) cm/s, P = 0.78. The peak systolic velocity, flow velocity and total volume flow at 40 min were not statistically significantly different from baseline for both casted and non-casted limb. Conclusion In healthy volunteers, the popliteal venous haemodynamics of the Jet Impulse Technology system was similar between the legs with and without a below-knee fibreglass cast. In-cast Jet Impulse Technology may provide a non-pharmacological option for venous thromboembolism prophylaxis for lower-limb cast-immobility. PMID:28203384
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, T.; Contos, L.; Adams, L.
1992-02-01
The purpose of this document is to present environmental monitoring data collected during the US DOE Limestone Injection Multistage Burner (LIMB) Demonstration Project Extension. The objective of the LIMB program is to demonstrate the sulfur dioxide (SO{sub 2}) and nitrogen oxide (NO{sub x}) emission reduction capabilities of the LIMB system. The LIMB system is a retrofit technology to be used for existing coal-fired boilers equipped with electrostatic precipitators. (VC)
Safari, Mohammad Reza; Rowe, Philip; Buis, Arjan
2012-01-01
Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP) and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements.
Safari, Mohammad Reza; Rowe, Philip; Buis, Arjan
2012-01-01
Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP) and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements. PMID:22619599
Shih, Ching-Tien; Shih, Ching-Hsiang; Luo, Ching-Hsing
2013-12-01
The latest researchers have employed software technology to turn gyration air mice into a high performance limb detector to detect specific limb movement, and to further collaborate using the preferred environmental stimulation to help people with disabilities to suppress unwanted behaviors or habits and to reward good behaviors. This study extended the functionality of a gyration air mouse, and used the mouse as a precise physical activity detector integrated with the preferred environmental stimulation to assess if this integrated set can be used to help two disabled people who are overweight and lacking in exercise to actively perform physical activities. The study was conducted based on an A-B-A-B design. The results showed that both participants increased significantly the time duration required for them to maintain their physical activity status so that they could obtain their favorite environmental stimulation during the intervention phases. Both the practical and developmental implications of the findings are then discussed. Copyright © 2013 Elsevier Ltd. All rights reserved.
Limb observations of the 12.32 micron solar emission line during the 1991 July total eclipse
NASA Technical Reports Server (NTRS)
Deming, Drake; Jennings, Donald E.; Mccabe, George; Noyes, Robert; Wiedemann, Gunter; Espenak, Fred
1992-01-01
The limb profile of the Mg I 12.32-micron emission line is determined by occultation in the July 11, 1991 total solar eclipse over Mauna Kea. It is shown that the emission peaks are very close to the 12-micron continuum limb, as predicted by recent theory for this line as a non-LTE photospheric emission. The increase in optical depth for this extreme limb-viewing situation indicates that most of the observed emission arises from above the chromospheric temperature minimum, and it is found that this emission is extended to heights well in excess of the model predictions. The line emission can be observed as high as 2000 km above the 12-micron continuum limb, whereas theory predicts it to remain observable no higher than about 500 km above the continuum limb. The substantial limb extension observed in this line is quantitatively consistent with limb extensions seen in the far-IR continuum, and it is concluded that it is indicative of departures from gravitational hydrostatic equilibrium, or spatial inhomogeneities, in the upper solar atmosphere.
Jayaraman, Arun; Burt, Sheila; Rymer, William Zev
2017-07-01
To review lower-limb technology currently available for people with neurological disorders, such as spinal cord injury, stroke, or other conditions. We focus on 3 emerging technologies: treadmill-based training devices, exoskeletons, and other wearable robots. Efficacy for these devices remains unclear, although preliminary data indicate that specific patient populations may benefit from robotic training used with more traditional physical therapy. Potential benefits include improved lower-limb function and a more typical gait trajectory. Use of these devices is limited by insufficient data, cost, and in some cases size of the machine. However, robotic technology is likely to become more prevalent as these machines are enhanced and able to produce targeted physical rehabilitation. Therapists should be aware of these technologies as they continue to advance but understand the limitations and challenges posed with therapeutic/mobility robots.
CRISM Limb Observations of Aerosols and Water Vapor
NASA Technical Reports Server (NTRS)
Smith, Michael D.; Wolff, M.J.; Clancy, R.T.; Seelos, F.; Murchie, S.L.
2009-01-01
Near-infrared spectra taken in a limb-viewing geometry by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) on-board the Mars Reconnaissance Orbiter (MRO) provide a useful tool for probing atmospheric structure. Here we describe preliminary work on the retrieval of vertical profiles of aerosols and water vapor from the CRISM limb observations. The first full set of CRISM limb observations was taken in July 2009, with subsequent limb observations planned once every two months. Each set of limb observations contains about four dozen scans across the limb giving pole-to-pole coverage for two orbits at roughly 100 and 290 W longitude. Radiative transfer modeling taking account of aerosol scattering in the limb-viewing geometry is used to model the observations. The retrievals show the height to which dust and water vapor extend and the location and height of water ice clouds. Results from the First set of CRISM limb observations (July 2009, Ls=300) show dust aerosol well-mixed to about three scale heights above the surface with thin water ice clouds above the dust near the equator and at mid-northern latitudes. Water vapor is concentrated at high southern latitudes.
Are human hands and feet affected by climate? A test of Allen's rule.
Betti, Lia; Lycett, Stephen J; von Cramon-Taubadel, Noreen; Pearson, Osbjorn M
2015-09-01
In recent years, several studies have shown that populations from cold, high-latitude regions tend to have relatively shorter limbs than populations from tropical regions, with most of the difference due to the relative length of the zeugopods (i.e., radius, ulna, tibia, fibula). This pattern has been explained either as the consequence of long-term climatic selection or of phenotypic plasticity, with temperature having a direct effect on bone growth during development. The aims of this study were to test whether this pattern of intra-limb proportions extended to the bones of the hands and feet, and to determine whether the pattern remained significant after taking into account the effects of neutral evolutionary processes related to population history. Measurements of the limb bones, including the first metatarsal and metacarpal, were collected for 393 individuals from 10 globally distributed human populations. The relationship between intra-limb indices and minimum temperature was tested using generalized least squares regression, correcting for spatial autocorrelation. The results confirmed previous observations of a temperature-related gradient in intra-limb proportions, even accounting for population history. This pattern extends to the hands, with populations from cold regions displaying a relatively shorter and stockier first metacarpal; however, the first metatarsal appears to be wider but not shorter in cold-adapted populations. The results suggest that climatic adaptation played a role in shaping variation in limb proportions between human populations. The different patterns shown by the hands and feet might be due to the presence of evolutionary constraints on the foot to maintain efficient bipedal locomotion. © 2015 Wiley Periodicals, Inc.
Limbs beyond the Skin: Exploring the Physical Realities of Digital Composition
ERIC Educational Resources Information Center
Doerr-Stevens, Candance
2011-01-01
This article discusses how prolonged participation and digital composition online intersect to forge material extensions of the physical body, or limbs beyond the skin. Based on postmodern theories of technology and the body, I argue that these limbs, while less tangible, merit serious consideration given their potential to engender physical…
Real-time inverse kinematics for the upper limb: a model-based algorithm using segment orientations.
Borbély, Bence J; Szolgay, Péter
2017-01-17
Model based analysis of human upper limb movements has key importance in understanding the motor control processes of our nervous system. Various simulation software packages have been developed over the years to perform model based analysis. These packages provide computationally intensive-and therefore off-line-solutions to calculate the anatomical joint angles from motion captured raw measurement data (also referred as inverse kinematics). In addition, recent developments in inertial motion sensing technology show that it may replace large, immobile and expensive optical systems with small, mobile and cheaper solutions in cases when a laboratory-free measurement setup is needed. The objective of the presented work is to extend the workflow of measurement and analysis of human arm movements with an algorithm that allows accurate and real-time estimation of anatomical joint angles for a widely used OpenSim upper limb kinematic model when inertial sensors are used for movement recording. The internal structure of the selected upper limb model is analyzed and used as the underlying platform for the development of the proposed algorithm. Based on this structure, a prototype marker set is constructed that facilitates the reconstruction of model-based joint angles using orientation data directly available from inertial measurement systems. The mathematical formulation of the reconstruction algorithm is presented along with the validation of the algorithm on various platforms, including embedded environments. Execution performance tables of the proposed algorithm show significant improvement on all tested platforms. Compared to OpenSim's Inverse Kinematics tool 50-15,000x speedup is achieved while maintaining numerical accuracy. The proposed algorithm is capable of real-time reconstruction of standardized anatomical joint angles even in embedded environments, establishing a new way for complex applications to take advantage of accurate and fast model-based inverse kinematics calculations.
Chromaticity of gravitational microlensing events
NASA Astrophysics Data System (ADS)
Han, Cheongho; Park, Seong-Hong; Jeong, Jang-Hae
2000-07-01
In this paper, we investigate the colour changes of gravitational microlensing events caused by the two different mechanisms of differential amplification for a limb-darkened extended source and blending. From this investigation, we find that the colour changes of limb-darkened extended source events (colour curves) have dramatically different characteristics depending on whether the lens transits the source star or not. We show that for a source transit event, the lens proper motion can be determined by simply measuring the turning time of the colour curve instead of fitting the overall colour or light curves. We also find that even for a very small fraction of blended light, the colour changes induced by blending are equivalent to those induced by limb darkening, causing serious distortion in the observed colour curve. Therefore, to obtain useful information about the lens and source star from the colour curve of an event, it will be essential to correct for blending. We discuss various methods of blending correction.
3D-printed upper limb prostheses: a review.
Ten Kate, Jelle; Smit, Gerwin; Breedveld, Paul
2017-04-01
This paper aims to provide an overview with quantitative information of existing 3D-printed upper limb prostheses. We will identify the benefits and drawbacks of 3D-printed devices to enable improvement of current devices based on the demands of prostheses users. A review was performed using Scopus, Web of Science and websites related to 3D-printing. Quantitative information on the mechanical and kinematic specifications and 3D-printing technology used was extracted from the papers and websites. The overview (58 devices) provides the general specifications, the mechanical and kinematic specifications of the devices and information regarding the 3D-printing technology used for hands. The overview shows prostheses for all different upper limb amputation levels with different types of control and a maximum material cost of $500. A large range of various prostheses have been 3D-printed, of which the majority are used by children. Evidence with respect to the user acceptance, functionality and durability of the 3D-printed hands is lacking. Contrary to what is often claimed, 3D-printing is not necessarily cheap, e.g., injection moulding can be cheaper. Conversely, 3D-printing provides a promising possibility for individualization, e.g., personalized socket, colour, shape and size, without the need for adjusting the production machine. Implications for rehabilitation Upper limb deficiency is a condition in which a part of the upper limb is missing as a result of a congenital limb deficiency of as a result of an amputation. A prosthetic hand can restore some of the functions of a missing limb and help the user in performing activities of daily living. Using 3D-printing technology is one of the solutions to manufacture hand prostheses. This overview provides information about the general, mechanical and kinematic specifications of all the devices and it provides the information about the 3D-printing technology used to print the hands.
A novel upper limb rehabilitation system with self-driven virtual arm illusion.
Aung, Yee Mon; Al-Jumaily, Adel; Anam, Khairul
2014-01-01
This paper proposes a novel upper extremity rehabilitation system with virtual arm illusion. It aims for fast recovery from lost functions of the upper limb as a result of stroke to provide a novel rehabilitation system for paralyzed patients. The system is integrated with a number of technologies that include Augmented Reality (AR) technology to develop game like exercise, computer vision technology to create the illusion scene, 3D modeling and model simulation, and signal processing to detect user intention via EMG signal. The effectiveness of the developed system has evaluated via usability study and questionnaires which is represented by graphical and analytical methods. The evaluation provides with positive results and this indicates the developed system has potential as an effective rehabilitation system for upper limb impairment.
Banks, Jim
2016-01-01
Using state-of-the-art technology, athletes at the Paralympic Games achieve great feats of physical prowess, but for most people using assistive and rehabilitative technologies (ART), even simple tasks can present huge challenges. Many do not make full use of the technology available to them because it is unreliable, uncomfortable, and nonintuitive, so researchers are pushing the envelope to create practical solutions that function like real limbs.
Premier's imaging IR limb sounder
NASA Astrophysics Data System (ADS)
Kraft, Stefan; Bézy, Jean-Loup; Meynart, Roland; Langen, Jörg; Carnicero Dominguez, Bernardo; Bensi, Paolo; Silvestrin, Pierluigi
2017-11-01
The Imaging IR Limb Sounder (IRLS) is one of the two instruments planned on board of the candidate Earth Explorer Core Mission PREMIER. PREMIER stands for PRocess Exploration through Measurements of Infrared and Millimetre-wave Emitted Radiation. PREMIER went recently through the process of a feasibility study (Phase A) within the Earth Observation Envelope Program. Emerging from recent advanced instrument technologies IRLS shall, next to a millimetre-wave limb sounder (called STEAMR), explore the benefits of three-dimensional limb sounding with embedded cloud imaging capability. Such 3D imaging technology is expected to open a new era of limb sounding that will allow detailed studies of the link between atmospheric composition and climate, since it will map simultaneously fields of temperature and many trace gases in the mid/upper troposphere and stratosphere across a large vertical and horizontal field of view and with high vertical and horizontal resolution. PREMIER shall fly in a tandem formation looking backwards to METOP's swath and thereby improve meteorological and environmental analyses.
Amputation and prosthesis implantation shape body and peripersonal space representations
Canzoneri, Elisa; Marzolla, Marilena; Amoresano, Amedeo; Verni, Gennaro; Serino, Andrea
2013-01-01
Little is known about whether and how multimodal representations of the body (BRs) and of the space around the body (Peripersonal Space, PPS) adapt to amputation and prosthesis implantation. In order to investigate this issue, we tested BR in a group of upper limb amputees by means of a tactile distance perception task and PPS by means of an audio-tactile interaction task. Subjects performed the tasks with stimulation either on the healthy limb or the stump of the amputated limb, while wearing or not wearing their prosthesis. When patients performed the tasks on the amputated limb, without the prosthesis, the perception of arm length shrank, with a concurrent shift of PPS boundaries towards the stump. Conversely, wearing the prosthesis increased the perceived length of the stump and extended the PPS boundaries so as to include the prosthetic hand, such that the prosthesis partially replaced the missing limb. PMID:24088746
The hindlimb in walking horses: 1. Kinematics and ground reaction forces.
Hodson, E; Clayton, H M; Lanovaz, J L
2001-01-01
The objective was to study associations between kinematics and ground reaction forces in the hindlimb of walking horses. Video (60 Hz) and force (2000 Hz) data were gathered for 8 strides from each of 5 sound horses during the walk. Sagittal plane kinematics were measured concurrently with the vertical and longitudinal ground reaction forces. The hindlimb showed rapid loading and braking in the initial 10% stride. The stifle, tarsal and coffin joints flexed and the fetlock joint extended during this period of rapid loading. The vertical ground reaction force showed 2 peaks separated by a dip; this pattern was similar to the fetlock joint angle-time graph. Peaks in the longitudinal ground reaction force did not appear to correspond with kinematic events. Total braking impulse was equal to total propulsive impulse over the entire stride. Flexion and extension of the hip were responsible for protraction and retraction of the entire limb. Maximal protraction occurred shortly before the end of swing and maximal retraction occurred during breakover. During the middle part of stance the tarsal joint extended slowly, while the stifle began to flex when the limb was retracted beyond the midstance position at 28% stride. Flexion cycles of the stifle and tarsal joints were well coordinated during the swing phase to raise the distal limb as it was protracted. The results demonstrate a relationship between limb kinematics and vertical limb loading in the hindlimbs of sound horses. Future studies will elucidate the alterations in response to lameness.
Robotics in Lower-Limb Rehabilitation after Stroke
2017-01-01
With the increase in the elderly, stroke has become a common disease, often leading to motor dysfunction and even permanent disability. Lower-limb rehabilitation robots can help patients to carry out reasonable and effective training to improve the motor function of paralyzed extremity. In this paper, the developments of lower-limb rehabilitation robots in the past decades are reviewed. Specifically, we provide a classification, a comparison, and a design overview of the driving modes, training paradigm, and control strategy of the lower-limb rehabilitation robots in the reviewed literature. A brief review on the gait detection technology of lower-limb rehabilitation robots is also presented. Finally, we discuss the future directions of the lower-limb rehabilitation robots. PMID:28659660
Robotics in Lower-Limb Rehabilitation after Stroke.
Zhang, Xue; Yue, Zan; Wang, Jing
2017-01-01
With the increase in the elderly, stroke has become a common disease, often leading to motor dysfunction and even permanent disability. Lower-limb rehabilitation robots can help patients to carry out reasonable and effective training to improve the motor function of paralyzed extremity. In this paper, the developments of lower-limb rehabilitation robots in the past decades are reviewed. Specifically, we provide a classification, a comparison, and a design overview of the driving modes, training paradigm, and control strategy of the lower-limb rehabilitation robots in the reviewed literature. A brief review on the gait detection technology of lower-limb rehabilitation robots is also presented. Finally, we discuss the future directions of the lower-limb rehabilitation robots.
Age-related variations of varicose veins anatomy.
Caggiati, Alberto; Rosi, Caterina; Heyn, Rosemarie; Franceschini, Marco; Acconcia, Maria Cristina
2006-12-01
Primary varicose veins are commonly considered a progressive disease starting from the saphenous junctions and extending to tributaries in a retrograde fashion along the saphenous trunks. This theory has been criticized by studies indicating different patterns of development and progression of varicose veins. To contribute to the understanding of the pathogenesis of the disease, the anatomy of the venous bed was comparatively evaluated by duplex sonography in patients with varicose veins with a marked difference in age. The study included 100 varicose limbs in 82 patients aged < 30 years and 238 limbs in 183 patients aged > 60 years. Veins were designated as saphenous veins (SVs), tributaries of the SVs (STVs), and veins not connected with the SVs (NSVs). Four main anatomic patterns were comparatively evaluated: (1) varicose changes only along SVs, (2) varicose changes along SVs and STVs, (3) varicose changes only in STVs, and (4) varicose changes only in NSVs. SVs were normal in 44% of varicose limbs. In most limbs from young subjects, varicose changes afflicted only SVTs (25%) and NSVs (36%). Varicose SVs were more frequent in the older group (62%) than in younger one (39%) owing to a higher prevalence of limbs with combined SV and STV varicosities (respectively, 59% and 37%). In the older group, varicosities in the STVs were more frequently observed in association with incompetence of the SV trunks. The frequent occurrence of normal SVs in varicose limbs of all patients does not support the crucial role commonly credited to SVs in the pathogenesis of primary varicosities. Moreover, the SV trunks were normal in most varicose limbs from young patients. These findings suggest that varicose disease may progressively extend in an antegrade fashion, spreading from the STVs to the SVs. This hypothesis suggests that the saphenous trunks could be spared in the treatment of a relevant number of varicose legs. Prospective longitudinal studies with serial duplex evaluations of large series of extremities are necessary to confirm this hypothesis.
Continuum limbed robots for locomotion
NASA Astrophysics Data System (ADS)
Mutlu, Alper
This thesis focuses on continuum robots based on pneumatic muscle technology. We introduce a novel approach to use these muscles as limbs of lightweight legged robots. The flexibility of the continuum legs of these robots offers the potential to perform some duties that are not possible with classical rigid-link robots. Potential applications are as space robots in low gravity, and as cave explorer robots. The thesis covers the fabrication process of continuum pneumatic muscles and limbs. It also provides some new experimental data on this technology. Afterwards, the designs of two different novel continuum robots - one tripod, one quadruped - are introduced. Experimental data from tests using the robots is provided. The experimental results are the first published example of locomotion with tripod and quadruped continuum legged robots. Finally, discussion of the results and how far this technology can go forward is presented.
Extending radiative transfer models by use of Bayes rule. [in atmospheric science
NASA Technical Reports Server (NTRS)
Whitney, C.
1977-01-01
This paper presents a procedure that extends some existing radiative transfer modeling techniques to problems in atmospheric science where curvature and layering of the medium and dynamic range and angular resolution of the signal are important. Example problems include twilight and limb scan simulations. Techniques that are extended include successive orders of scattering, matrix operator, doubling, Gauss-Seidel iteration, discrete ordinates and spherical harmonics. The procedure for extending them is based on Bayes' rule from probability theory.
Scott, Stephen H; Dukelow, Sean P
2011-01-01
Robotic technologies have profoundly affected the identification of fundamental properties of brain function. This success is attributable to robots being able to control the position of or forces applied to limbs, and their inherent ability to easily, objectively, and reliably quantify sensorimotor behavior. Our general hypothesis is that these same attributes make robotic technologies ideal for clinically assessing sensory, motor, and cognitive impairments in stroke and other neurological disorders. Further, they provide opportunities for novel therapeutic strategies. The present opinionated review describes how robotic technologies combined with virtual/augmented reality systems can support a broad range of behavioral tasks to objectively quantify brain function. This information could potentially be used to provide more accurate diagnostic and prognostic information than is available from current clinical assessment techniques. The review also highlights the potential benefits of robots to provide upper-limb therapy. Although the capital cost of these technologies is substantial, it pales in comparison with the potential cost reductions to the overall healthcare system that improved assessment and therapeutic interventions offer.
Limb-use by foraging marine turtles, an evolutionary perspective
McLeish, Don; Brooks, Andrew J.; Gaskell, John; Van Houtan, Kyle S.
2018-01-01
The use of limbs for foraging is documented in both marine and terrestrial tetrapods. These behaviors were once believed to be less likely in marine tetrapods due to the physical constraints of body plans adapted to locomotion in a fluid environment. Despite these obstacles, ten distinct types of limb-use while foraging have been previously reported in nine marine tetrapod families. Here, we expand the types of limb-use documented in marine turtles and put it in context with the diversity of marine tetrapods currently known to use limbs for foraging. Additionally, we suggest that such behaviors could have occurred in ancestral turtles, and thus, possibly extend the evolutionary timeline of limb-use behavior in marine tetrapods back approximately 70 million years. Through direct observation in situ and crowd-sourcing, we document the range of behaviors across habitats and prey types, suggesting its widespread occurrence. We argue the presence of these behaviors among marine tetrapods may be limited by limb mobility and evolutionary history, rather than foraging ecology or social learning. These behaviors may also be remnant of ancestral forelimb-use that have been maintained due to a semi-aquatic life history. PMID:29610708
Limb-use by foraging marine turtles, an evolutionary perspective.
Fujii, Jessica A; McLeish, Don; Brooks, Andrew J; Gaskell, John; Van Houtan, Kyle S
2018-01-01
The use of limbs for foraging is documented in both marine and terrestrial tetrapods. These behaviors were once believed to be less likely in marine tetrapods due to the physical constraints of body plans adapted to locomotion in a fluid environment. Despite these obstacles, ten distinct types of limb-use while foraging have been previously reported in nine marine tetrapod families. Here, we expand the types of limb-use documented in marine turtles and put it in context with the diversity of marine tetrapods currently known to use limbs for foraging. Additionally, we suggest that such behaviors could have occurred in ancestral turtles, and thus, possibly extend the evolutionary timeline of limb-use behavior in marine tetrapods back approximately 70 million years. Through direct observation in situ and crowd-sourcing, we document the range of behaviors across habitats and prey types, suggesting its widespread occurrence. We argue the presence of these behaviors among marine tetrapods may be limited by limb mobility and evolutionary history, rather than foraging ecology or social learning. These behaviors may also be remnant of ancestral forelimb-use that have been maintained due to a semi-aquatic life history.
Timmermans, Annick AA; Seelen, Henk AM; Willmann, Richard D; Kingma, Herman
2009-01-01
Background It is the purpose of this article to identify and review criteria that rehabilitation technology should meet in order to offer arm-hand training to stroke patients, based on recent principles of motor learning. Methods A literature search was conducted in PubMed, MEDLINE, CINAHL, and EMBASE (1997–2007). Results One hundred and eighty seven scientific papers/book references were identified as being relevant. Rehabilitation approaches for upper limb training after stroke show to have shifted in the last decade from being analytical towards being focussed on environmentally contextual skill training (task-oriented training). Training programmes for enhancing motor skills use patient and goal-tailored exercise schedules and individual feedback on exercise performance. Therapist criteria for upper limb rehabilitation technology are suggested which are used to evaluate the strengths and weaknesses of a number of current technological systems. Conclusion This review shows that technology for supporting upper limb training after stroke needs to align with the evolution in rehabilitation training approaches of the last decade. A major challenge for related technological developments is to provide engaging patient-tailored task oriented arm-hand training in natural environments with patient-tailored feedback to support (re) learning of motor skills. PMID:19154570
An extremely lightweight fingernail worn prosthetic interface device
NASA Astrophysics Data System (ADS)
Yetkin, Oguz; Ahluwalia, Simranjit; Silva, Dinithi; Kasi-Okonye, Isioma; Volker, Rachael; Baptist, Joshua R.; Popa, Dan O.
2016-05-01
Upper limb prosthetics are currently operated using several electromyography sensors mounted on an amputee's residual limb. In order for any prosthetic driving interface to be widely adopted, it needs to be responsive, lightweight, and out of the way when not being used. In this paper we discuss the possibility of replacing such electrodes with fingernail optical sensor systems mounted on the sound limb. We present a prototype device that can detect pinch gestures and communicate with the prosthetic system. The device detects the relative position of fingers to each other by measuring light transmitted via tissue. Applications are not limited to prosthetic control, but can be extended to other human-machine interfaces.
Paralympic Sprint Performance Between 1992 and 2012.
Grobler, Lara; Ferreira, Suzanne; Terblanche, Elmarie
2015-11-01
The Paralympic Games have undergone many changes since their inception in 1960, one being the advances made in running-specific prostheses (RSPs) for track athletes with lower-limb amputations. To investigate the sprinting-performance changes in athletes with lower-limb amputations since 1992 to assess whether the influence of developments in RSP technology is evident. The results of the Olympic and Paralympic Games ranging between 1992 and 2012 for the 100-m and 200-m were collected, and performance trends, percentage change in performance, and competition density (CD) were calculated. The results indicate that the greatest performance increases were seen in athletes with lower-limb amputations (T42 = 26%, T44 = 14%). These performance improvements were greater than for Olympic athletes (<3%), as well as Paralympic athletes from other selected classes (<10%). The T42 and T44 classes also showed the lowest CD values. These results suggest that although there is an overall trend for improved Paralympic sprint performances, RSP technology has played a noteworthy role in the progression of performances of athletes with amputations. It is also hypothesized that the difference in the performance improvements between the T42 and T44 classes is due to the level of disability and therefore the extent to which technology is required to enable locomotion. It is evident that RSP technology has played a significant role in the progression of performances in athletes with lower-limb amputations.
Imparting regenerative capacity to limbs by progenitor cell transplantation
Lin, Gufa; Chen, Ying; Slack, Jonathan M.W.
2012-01-01
Summary The frog Xenopus can normally regenerate its limbs at early developmental stages but loses the ability during metamorphosis. This behavior provides a potential gain-of-function model for measures that can enhance limb regeneration. Here we show that frog limbs can be caused to form multidigit regenerates after receiving transplants of larval limb progenitor cells. It is necessary to activate Wnt/β -catenin signaling in the cells, and to add Sonic hedgehog, FGF10 and thymosin β4. These factors promote survival and growth of the grafted cells and also provide pattern information. The eventual regenerates are not composed solely of donor tissue; the host cells also make a substantial contribution despite their lack of regeneration-competence. Cells from adult frog legs or from regenerating tadpole tails do not promote limb regeneration, demonstrating the necessity for limb progenitor cells. These findings have obvious implications for the development of a technology to promote limb regeneration in mammals. PMID:23273877
DEVELOPMENTS IN LIMB (LIMESTONE INJECTION MULTISTAGE BURNER) TECHNOLOGY
The paper describes the most recent results from the Limestone Injection Multistage Burner (LIMB) program, results from the wall-fired demonstration. Tests were conducted to determine the efficacy of commercial calcium hydroxide--Ca(OH)2--supplied by Marblehead Lime Co. and of ca...
Advanced upper limb prosthetic devices: implications for upper limb prosthetic rehabilitation.
Resnik, Linda; Meucci, Marissa R; Lieberman-Klinger, Shana; Fantini, Christopher; Kelty, Debra L; Disla, Roxanne; Sasson, Nicole
2012-04-01
The number of catastrophic injuries caused by improvised explosive devices in the Afghanistan and Iraq Wars has increased public, legislative, and research attention to upper limb amputation. The Department of Veterans Affairs (VA) has partnered with the Defense Advanced Research Projects Agency and DEKA Integrated Solutions to optimize the function of an advanced prosthetic arm system that will enable greater independence and function. In this special communication, we examine current practices in prosthetic rehabilitation including trends in adoption and use of prosthetic devices, financial considerations, and the role of rehabilitation team members in light of our experiences with a prototype advanced upper limb prosthesis during a VA study to optimize the device. We discuss key challenges in the adoption of advanced prosthetic technology and make recommendations for service provision and use of advanced upper limb prosthetics. Rates of prosthetic rejection are high among upper limb amputees. However, these rates may be reduced with sufficient training by a highly specialized, multidisciplinary team of clinicians, and a focus on patient education and empowerment throughout the rehabilitation process. There are significant challenges emerging that are unique to implementing the use of advanced upper limb prosthetic technology, and a lack of evidence to establish clinical guidelines regarding prosthetic prescription and treatment. Finally, we make recommendations for future research to aid in the identification of best practices and development of policy decisions regarding insurance coverage of prosthetic rehabilitation. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Technologies Assessing Limb Bradykinesia in Parkinson's Disease.
Hasan, Hasan; Athauda, Dilan S; Foltynie, Thomas; Noyce, Alastair J
2017-01-01
The MDS-UPDRS (Movement Disorders Society - Unified Parkinson's Disease Rating Scale) is the most widely used scale for rating impairment in PD. Subscores measuring bradykinesia have low reliability that can be subject to rater variability. Novel technological tools can be used to overcome such issues. To systematically explore and describe the available technologies for measuring limb bradykinesia in PD that were published between 2006 and 2016. A systematic literature search using PubMed (MEDLINE), IEEE Xplore, Web of Science, Scopus and Engineering Village (Compendex and Inspec) databases was performed to identify relevant technologies published until 18 October 2016. 47 technologies assessing bradykinesia in PD were identified, 17 of which offered home and clinic-based assessment whilst 30 provided clinic-based assessment only. Of the eligible studies, 7 were validated in a PD patient population only, whilst 40 were tested in both PD and healthy control groups. 19 of the 47 technologies assessed bradykinesia only, whereas 28 assessed other parkinsonian features as well. 33 technologies have been described in additional PD-related studies, whereas 14 are not known to have been tested beyond the pilot phase. Technology based tools offer advantages including objective motor assessment and home monitoring of symptoms, and can be used to assess response to intervention in clinical trials or routine care. This review provides an up-to-date repository and synthesis of the current literature regarding technology used for assessing limb bradykinesia in PD. The review also discusses the current trends with regards to technology and discusses future directions in development.
Rink, Cameron L; Wernke, Matthew M; Powell, Heather M; Tornero, Mark; Gnyawali, Surya C; Schroeder, Ryan M; Kim, Jayne Y; Denune, Jeffrey A; Albury, Alexander W; Gordillo, Gayle M; Colvin, James M; Sen, Chandan K
2017-07-01
Objective: (1) Develop a standardized approach to quantitatively measure residual limb skin health. (2) Report reference residual limb skin health values in people with transtibial and transfemoral amputation. Approach: Residual limb health outcomes in individuals with transtibial ( n = 5) and transfemoral ( n = 5) amputation were compared to able-limb controls ( n = 4) using noninvasive imaging (hyperspectral imaging and laser speckle flowmetry) and probe-based approaches (laser doppler flowmetry, transcutaneous oxygen, transepidermal water loss, surface electrical capacitance). Results: A standardized methodology that employs noninvasive imaging and probe-based approaches to measure residual limb skin health are described. Compared to able-limb controls, individuals with transtibial and transfemoral amputation have significantly lower transcutaneous oxygen tension, higher transepidermal water loss, and higher surface electrical capacitance in the residual limb. Innovation: Residual limb health as a critical component of prosthesis rehabilitation for individuals with lower limb amputation is understudied in part due to a lack of clinical measures. Here, we present a standardized approach to measure residual limb health in people with transtibial and transfemoral amputation. Conclusion: Technology advances in noninvasive imaging and probe-based measures are leveraged to develop a standardized approach to quantitatively measure residual limb health in individuals with lower limb loss. Compared to able-limb controls, resting residual limb physiology in people that have had transfemoral or transtibial amputation is characterized by lower transcutaneous oxygen tension and poorer skin barrier function.
From LIMS to OMPS-LP: limb ozone observations for future reanalyses
NASA Astrophysics Data System (ADS)
Wargan, K.; Kramarova, N. A.; Remsberg, E. E.; Coy, L.; Harvey, L.; Livesey, N. J.; Pawson, S.
2017-12-01
High vertical resolution and accuracy of ozone data from satellite-borne limb sounders have made them an invaluable tool in scientific studies of the middle and upper atmosphere. However, it was not until recently that these measurements were successfully incorporated in atmospheric reanalyses: of the major multidecadal reanalyses only ECMWF's ERA-Interim/ERA5 and NASA's MERRA-2 use limb ozone data. Validation and comparison studies have demonstrated that the addition of observations from the Microwave Limb Sounder (MLS) on EOS Aura greatly improved the quality of ozone fields in MERRA-2 making these assimilated data sets useful for scientific research. In this presentation, we will show the results of test experiments assimilating retrieved ozone from the Limb Infrared Monitor of the Stratosphere (LIMS, 1978/1979) and Ozone Mapping Profiler Suite Limb Profiler (OMPS-LP, 2012 to present). Our approach builds on the established assimilation methodology used for MLS in MERRA-2 and, in the case of OMPS-LP, extends the excellent record of MLS ozone assimilation into the post-EOS era in Earth observations. We will show case studies, discuss comparisons of the new experiments with MERRA-2, strategies for bias correction and the potential for combined assimilation of multiple limb ozone data types in future reanalyses for studies of multidecadal stratospheric ozone changes including trends.
Analysis of Msx1; Msx2 double mutants reveals multiple roles for Msx genes in limb development.
Lallemand, Yvan; Nicola, Marie-Anne; Ramos, Casto; Bach, Antoine; Cloment, Cécile Saint; Robert, Benoît
2005-07-01
The homeobox-containing genes Msx1 and Msx2 are highly expressed in the limb field from the earliest stages of limb formation and, subsequently, in both the apical ectodermal ridge and underlying mesenchyme. However, mice homozygous for a null mutation in either Msx1 or Msx2 do not display abnormalities in limb development. By contrast, Msx1; Msx2 double mutants exhibit a severe limb phenotype. Our analysis indicates that these genes play a role in crucial processes during limb morphogenesis along all three axes. Double mutant limbs are shorter and lack anterior skeletal elements (radius/tibia, thumb/hallux). Gene expression analysis confirms that there is no formation of regions with anterior identity. This correlates with the absence of dorsoventral boundary specification in the anterior ectoderm, which precludes apical ectodermal ridge formation anteriorly. As a result, anterior mesenchyme is not maintained, leading to oligodactyly. Paradoxically, polydactyly is also frequent and appears to be associated with extended Fgf activity in the apical ectodermal ridge, which is maintained up to 14.5 dpc. This results in a major outgrowth of the mesenchyme anteriorly, which nevertheless maintains a posterior identity, and leads to formation of extra digits. These defects are interpreted in the context of an impairment of Bmp signalling.
Modification of hemiplegic compensatory gait pattern by symmetry-based motion controller of HAL.
Kawamoto, Hiroaki; Kadone, Hideki; Sakurai, Takeru; Sankai, Yoshiyuki
2015-01-01
As one of several characteristics of hemiplegic patients after stroke, compensatory gait caused by affected limb is often seen. The purpose of this research is to apply a symmetry-based controller of a wearable type lower limb robot, Hybrid Assistive Limb (HAL) to hemiplegic patients with compensatory gait, and to investigate improvement of gait symmetry. The controller is designed respectively for swing phase and support phase according to characteristics of hemiplegic gait pattern. The controller during swing phase stores the motion of the unaffected limb and then provides motion support on the affected limb during the subsequent swing using the stored pattern to realize symmetric gait based on spontaneous limb swing. Moreover, the controller during support phase provides motion to extend hip and knee joints to support wearer's body. Clinical tests were conducted in order to assess the modification of gait symmetry. Our case study involved participation of one chronic stroke patient who performs abnormally-compensatory gait for both of the affected and unaffected limbs. As a result, the patient's gait symmetry was improved by providing motion support during the swing phase on the affected side and motion constraint during the support phase on the unaffected side. The study showed promising basis for the effectiveness of the controller for the future clinical study.
Regeneration and repair of human digits and limbs: fact and fiction
Cheng, Tsun‐Chih
2015-01-01
Abstract A variety of digit and limb repair and reconstruction methods have been used in different clinical settings, but regeneration remains an item on every plastic surgeon's “wish list.” Although surgical salvage techniques are continually being improved, unreplantable digits and limbs are still abundant. We comprehensively review the structural and functional salvage methods in clinical practice, from the peeling injuries of small distal fingertips to multisegmented amputated limbs, and the developmental and tissue engineering approaches for regenerating human digits and limbs in the laboratory. Although surgical techniques have forged ahead, there are still situations in which digits and limbs are unreplantable. Advances in the field are delineated, and the regeneration processes of salamander limbs, lizard tails, and mouse digits and each component of tissue engineering approaches for digit‐ and limb‐building are discussed. Although the current technology is promising, there are many challenges in human digit and limb regeneration. We hope this review inspires research on the critical gap between clinical and basic science, and leads to more sophisticated digit and limb loss rescue and regeneration innovations. PMID:27499873
Limb-girdle muscular dystrophy subtypes: First-reported cohort from northeastern China
Mahmood, Omar Abdulmonem; Jiang, Xinmei; Zhang, Qi
2013-01-01
The relative frequencies of different subtypes of limb-girdle muscular dystrophies vary widely among different populations. We estimated the percentage of limb-girdle muscular dystrophy subtypes in Chinese people based on 68 patients with limb-girdle muscular dystrophy from the Myology Clinic, Neurology Department, First Hospital of Jilin University, China. A diagnosis of calpainopathy was made in 12 cases (17%), and dysferlin deficiency in 10 cases (15%). Two biopsies revealed α-sarcoglycan deficiency (3%), and two others revealed a lack of caveolin-3 (3%). A diagnosis of unclassified limb-girdle muscular dystrophy was made in the remaining patients (62%). The appearances of calpain 3- and dysferlin-deficient biopsies were similar, though rimmed vacuoles were unique to dysferlinopathy, while inflammatory infiltrates were present in both these limb-girdle muscular dystrophy type 2D biopsies. Macrophages were detected in seven dysferlinopathy biopsies. The results of this study suggest that the distribution of limb-girdle muscular dystrophy subtypes in the Han Chinese population is similar to that reported in the West. The less necrotic, regenerating and inflammatory appearance of limb-girdle muscular dystrophy type 2A, but with more lobulated fibers, supports the idea that calpainopathy is a less active, but more chronic disease than dysferlinopathy. Unusual features indicated an extended limb-girdle muscular dystrophy disease spectrum. The use of acid phosphatase stain should be considered in suspected dysferlinopathies. To the best of our knowledge, this is the first report to define the relative proportions of the various forms of limb-girdle muscular dystrophy in China, based on protein testing. PMID:25206500
Upper Limb Posture Estimation in Robotic and Virtual Reality-Based Rehabilitation
Cortés, Camilo; Ardanza, Aitor; Molina-Rueda, F.; Cuesta-Gómez, A.; Ruiz, Oscar E.
2014-01-01
New motor rehabilitation therapies include virtual reality (VR) and robotic technologies. In limb rehabilitation, limb posture is required to (1) provide a limb realistic representation in VR games and (2) assess the patient improvement. When exoskeleton devices are used in the therapy, the measurements of their joint angles cannot be directly used to represent the posture of the patient limb, since the human and exoskeleton kinematic models differ. In response to this shortcoming, we propose a method to estimate the posture of the human limb attached to the exoskeleton. We use the exoskeleton joint angles measurements and the constraints of the exoskeleton on the limb to estimate the human limb joints angles. This paper presents (a) the mathematical formulation and solution to the problem, (b) the implementation of the proposed solution on a commercial exoskeleton system for the upper limb rehabilitation, (c) its integration into a rehabilitation VR game platform, and (d) the quantitative assessment of the method during elbow and wrist analytic training. Results show that this method properly estimates the limb posture to (i) animate avatars that represent the patient in VR games and (ii) obtain kinematic data for the patient assessment during elbow and wrist analytic rehabilitation. PMID:25110698
Engineering and Technology in Wheelchair Sport.
Cooper, Rory A; Tuakli-Wosornu, Yetsa A; Henderson, Geoffrey V; Quinby, Eleanor; Dicianno, Brad E; Tsang, Kalai; Ding, Dan; Cooper, Rosemarie; Crytzer, Theresa M; Koontz, Alicia M; Rice, Ian; Bleakney, Adam W
2018-05-01
Technologies capable of projecting injury and performance metrics to athletes and coaches are being developed. Wheelchair athletes must be cognizant of their upper limb health; therefore, systems must be designed to promote efficient transfer of energy to the handrims and evaluated for simultaneous effects on the upper limbs. This article is brief review of resources that help wheelchair users increase physiologic response to exercise, develop ideas for adaptive workout routines, locate accessible facilities and outdoor areas, and develop wheelchair sports-specific skills. Published by Elsevier Inc.
Oh, Pyung Chun; Kim, Minsu; Shin, Eak Kyun; Kang, Woong Chol
2018-04-20
Although the technology of endovascular aortic repair (EVAR) for abdominal aortic aneurysm (AAA) is evolving that make it appealing for challenging anatomy, proximal aortic neck morphology, especially severe angulation, is still one of the most determinants for a successful procedure. We describe a patient of AAA with severely angulated proximal neck, in whom kinked stent graft limb occurred against severe angulation of proximal neck. Then, we suggested how to prevent this complication in the second patient. Our case demonstrated the stent graft limb could be kinked by severe aortic neck angulation, making it challenging. However, the kinked stent graft limb could be prevented by deploying stent graft limbs below the most severely angulated aortic neck intentionally.
The Use of Quantitative SPECT/CT Imaging to Assess Residual Limb Health
2016-10-01
AWARD NUMBER: W81XWH-15-1-0669 TITLE: The Use of Quantitative SPECT/CT Imaging to Assess Residual Limb Health PRINCIPAL INVESTIGATOR...3. DATES COVERED 30 Sep 2015 - 29 Sep 2016 4. TITLE AND SUBTITLE The Use of Quantitative SPECT/CT Imaging to Assess Residual Limb Health 5a...amputation and subsequently evaluate the utility of non-invasive imaging for evaluating the impact of next-generation socket technologies on the health of
Assistive technologies after stroke: self-management or fending for yourself? A focus group study
2013-01-01
Background Assistive Technologies, defined as “electrical or mechanical devices designed to help people recover movement” have demonstrated clinical benefits in upper-limb stroke rehabilitation. Stroke services are becoming community-based and more reliant on self-management approaches. Assistive technologies could become important tools within self-management, however, in practice, few people currently use assistive technologies. This study investigated patients’, family caregivers and health professionals’ experiences and perceptions of stroke upper-limb rehabilitation and assistive technology use and identified the barriers and facilitators to their use in supporting stroke self-management. Methods A three-day exhibition of assistive technologies was attended by 204 patients, family caregivers/friends and health professionals. Four focus groups were conducted with people purposively sampled from exhibition attendees. They included i) people with stroke who had used assistive technologies (n = 5), ii) people with stroke who had not used assistive technologies (n = 6), iii) family caregivers (n = 5) and iv) health professionals (n = 6). The audio-taped focus groups were facilitated by a moderator and observer. All participants were asked to discuss experiences, strengths, weaknesses, barriers and facilitators to using assistive technologies. Following transcription, data were analysed using thematic analysis. Results All respondents thought assistive technologies had the potential to support self-management but that this opportunity was currently unrealised. All respondents considered assistive technologies could provide a home-based solution to the need for high intensity upper-limb rehabilitation. All stakeholders also reported significant barriers to assistive technology use, related to i) device design ii) access to assistive technology information and iii) access to assistive technology provision. The lack of and need for a coordinated system for assistive technology provision was apparent. A circular limitation of lack of evidence in clinical settings, lack of funded provision, lack of health professional knowledge about assistive technologies and confidence in prescribing them leading to lack of assistive technology service provision meant that often patients either received no assistive technologies or they and/or their family caregivers liaised directly with manufacturers without any independent expert advice. Conclusions Considerable systemic barriers to realising the potential of assistive technologies in upper-limb stroke rehabilitation were reported. Attention needs to be paid to increasing evidence of assistive technology effectiveness and develop clinical service provision. Device manufacturers, researchers, health professionals, service funders and people with stroke and family caregivers need to work creatively and collaboratively to develop new funding models, improve device design and increase knowledge and training in assistive technology use. PMID:23968362
A review for pediatricians on limb lengthening and the Ilizarov method.
Herbert, A J; Herzenberg, J E; Paley, D
1995-02-01
As recently as 1986, limb lengthening in children was considered by most North American orthopedic surgeons to be both dangerous and impractical. Previous attempts were plagued by unacceptably high rates of serious complications such as nerve palsy, deep infection, malunion, broken hardware, and stiff joints. With the recent introduction of the Russian Ilizarov method and apparatus for limb lengthening, a tremendous groundswell of interest has risen. Despite a steep learning curve, many Western centers have now reproduced Ilizarov's clinical results. The important advances over prior methods are partly biologic and partly hardware related. Ilizarov's principles require a minimally invasive, low-energy osteotomy, stable external fixation, a latency period before commencing distraction, and gradual lengthening of 1 mm/d in divided doses (0.25 mm four times per day). The article reviews the background of this new technique and provides an update on results reported over the past year. There is disagreement regarding precise indications for limb salvage (lengthening) of congenital limb deficiencies versus amputation. The role of extended lengthening in dwarfism also remains controversial.
Advances in upper limb stroke rehabilitation: a technology push.
Loureiro, Rui C V; Harwin, William S; Nagai, Kiyoshi; Johnson, Michelle
2011-10-01
Strokes affect thousands of people worldwide leaving sufferers with severe disabilities affecting their daily activities. In recent years, new rehabilitation techniques have emerged such as constraint-induced therapy, biofeedback therapy and robot-aided therapy. In particular, robotic techniques allow precise recording of movements and application of forces to the affected limb, making it a valuable tool for motor rehabilitation. In addition, robot-aided therapy can utilise visual cues conveyed on a computer screen to convert repetitive movement practice into an engaging task such as a game. Visual cues can also be used to control the information sent to the patient about exercise performance and to potentially address psychosomatic variables influencing therapy. This paper overviews the current state-of-the-art on upper limb robot-mediated therapy with a focal point on the technical requirements of robotic therapy devices leading to the development of upper limb rehabilitation techniques that facilitate reach-to-touch, fine motor control, whole-arm movements and promote rehabilitation beyond hospital stay. The reviewed literature suggest that while there is evidence supporting the use of this technology to reduce functional impairment, besides the technological push, the challenge ahead lies on provision of effective assessment of outcome and modalities that have a stronger impact transferring functional gains into functional independence.
Electrically stimulated signals from a long-term Regenerative Peripheral Nerve Interface.
Langhals, Nicholas B; Woo, Shoshana L; Moon, Jana D; Larson, John V; Leach, Michelle K; Cederna, Paul S; Urbanchek, Melanie G
2014-01-01
Despite modern technological advances, the most widely available prostheses provide little functional recovery beyond basic grasping. Although sophisticated upper extremity prostheses are available, optimal prosthetic interfaces which give patients high-fidelity control of these artificial limbs are limited. We have developed a novel Regenerative Peripheral Nerve Interface (RPNI), which consists of a unit of free muscle that has been neurotized by a transected peripheral nerve. In conjunction with a biocompatible electrode on the muscle surface, the RPNI facilitates signal transduction from a residual peripheral nerve to a neuroprosthetic limb. The purpose of this study was to explore signal quality and reliability in an RPNI following an extended period of implantation. Following a 14-month maturation period, electromyographic signal generation was evaluated via electrical stimulation of the innervating nerve. The long-term RPNI was viable and healthy, as demonstrated by evoked compound muscle action potentials as well as histological tissue analysis. Signals exceeding 4 mV were successfully acquired and amplitudes were consistent across multiple repetitions of applied stimuli. There were no evident signs of muscle denervation, significant scar tissue, or muscle necrosis. This study provides further evidence that after a maturation period exceeding 1 year, reliable and consistent signals can still be acquired from an RPNI.
Young People's Computer Use: Implications for Health Education
ERIC Educational Resources Information Center
Alexander, Leslie M.; Currie, Candace
2004-01-01
Increasing numbers of young people use Information and Communication Technology (ICT) for education, work and leisure activities. Research on ICT and Upper Limb Disorders (ULDs) in adults has shown that functional impairment, pain and discomfort in the upper limbs, neck and shoulder increases with frequency and duration of exposure to computer…
Technologies Assessing Limb Bradykinesia in Parkinson’s Disease
Hasan, Hasan; Athauda, Dilan S.; Foltynie, Thomas; Noyce, Alastair J.
2017-01-01
Background: The MDS-UPDRS (Movement Disorders Society – Unified Parkinson’s Disease Rating Scale) is the most widely used scale for rating impairment in PD. Subscores measuring bradykinesia have low reliability that can be subject to rater variability. Novel technological tools can be used to overcome such issues. Objective: To systematically explore and describe the available technologies for measuring limb bradykinesia in PD that were published between 2006 and 2016. Methods: A systematic literature search using PubMed (MEDLINE), IEEE Xplore, Web of Science, Scopus and Engineering Village (Compendex and Inspec) databases was performed to identify relevant technologies published until 18 October 2016. Results: 47 technologies assessing bradykinesia in PD were identified, 17 of which offered home and clinic-based assessment whilst 30 provided clinic-based assessment only. Of the eligible studies, 7 were validated in a PD patient population only, whilst 40 were tested in both PD and healthy control groups. 19 of the 47 technologies assessed bradykinesia only, whereas 28 assessed other parkinsonian features as well. 33 technologies have been described in additional PD-related studies, whereas 14 are not known to have been tested beyond the pilot phase. Conclusion: Technology based tools offer advantages including objective motor assessment and home monitoring of symptoms, and can be used to assess response to intervention in clinical trials or routine care. This review provides an up-to-date repository and synthesis of the current literature regarding technology used for assessing limb bradykinesia in PD. The review also discusses the current trends with regards to technology and discusses future directions in development. PMID:28222539
HOW DOES ADDING AND REMOVING LIQUID FROM SOCKET BLADDERS AFFECT RESIDUAL LIMB FLUID VOLUME?
Sanders, JE; Cagle, JC; Harrison, DS; Myers, TR; Allyn, KJ
2015-01-01
Adding and removing liquid from socket bladders is a means for people with limb loss to accommodate residual limb volume change. Nineteen people with trans-tibial amputation using their regular prosthetic socket fitted with fluid bladders on the inside socket surface underwent cycles of bladder liquid addition and removal. In each cycle, subjects sat, stood, and walked for 90s with bladder liquid added and then sat, stood, and walking for 90s again with the bladder liquid removed. The amount of bladder liquid added was increased in each cycle. Bioimpedance analysis was implemented to measure residual limb fluid volume. Results showed that the preferred bladder liquid volume was 16.8 mL (s.d.8.4), corresponding to 1.7% (s.d.0.8%) of the average socket volume between the bioimpedance voltage-sensing electrodes. Limb fluid volume driven out of the residual limb when bladder liquid was added was typically not recovered upon subsequent bladder liquid removal. Fifteen of nineteen subjects experienced a gradual limb fluid volume loss over the test session. Care should be taken when implementing adjustable socket technologies in people with limb amputation. Reducing socket volume may accentuate limb fluid volume loss. PMID:24203546
Can new technologies improve upper limb performance in grown-up diplegic children?
Turconi, Anna C; Biffi, Emilia; Maghini, Cristina; Peri, Elisabetta; Servodio Iammarone, Fernanda; Gagliardi, Chiara
2016-10-01
Few systematic studies describe rehabilitation trainings for upper limb in diplegic children with cerebral palsy (CP), who - especially once grown up - are often not considered as a target for rehabilitation interventions. In this pilot study, we describe the details and the effectiveness of an intensive, technology assisted intervention for upper limb. The treatment combines the utilization of Armeo® Spring with a training focused on hand/finger fluency and dexterity in a pre-post treatment experimental design. Participants were ten school-aged children (mean age 11.2) with bilateral CP and diplegia, attending mainstream schools. Participants underwent 40 therapy sessions in four weeks. Armeo® Spring measures, standardized motor and perceptual outcome indexes, as well as everyday life indicators were utilized to assess the effect of the intervention. Upper limb coordination, fluency and quality of movements mainly of hands and fingers significantly improved, with a good transferability to everyday life also in areas not specifically trained, such as self-care abilities and mobility. Probably due to the visual feedback provided by the virtual reality setting (which was all in one the context, the incentive and the product of activities), perceptual abilities significantly improved, too. Our study suggests the importance of intervention on upper limb even in milder CP diplegic forms and in relatively grown-up children. The possibility of modification at least partially relies on learning processes that are active all along development and benefit from stimulation. Though further studies with control groups and follow-up perspective are needed to confirm, new technologies offer interesting possibilities to be integrated into new evidence-based rehabilitation models.
Remote monitoring of lower-limb prosthetic socket fit using wireless technologies.
Sahandi, R; Sewell, P; Noroozi, S; Hewitt, M
2012-01-01
Accurate fitting of a lower-limb prosthetic socket is the most important factor affecting amputee satisfaction and rehabilitation. The technology is now available to allow real-time monitoring of in-service pressure distribution of prosthetic limbs. This paper proposes a remote interfacial pressure monitoring system necessary for the assessment of fit. The suitability of a wireless ZigBee network due to its relevant technical specification is investigated. The system enables remote monitoring of a prosthetic socket and its fit under different operating conditions thereby improving design, efficiency and effectiveness. The data can be used by prosthetists and may also be recorded for future training or for patient progress monitoring. This can minimize the number of iterations by getting it right first time, thereby minimizing the number of replacement prostheses. Copyright © 2012 Informa UK, Ltd.
Thoracic limb morphology of the red panda (Ailurus fulgens) evidenced by osteology and radiography.
Makungu, Modesta; Groenewald, Hermanus B; du Plessis, Wencke M; Barrows, Michelle; Koeppel, Katja N
2015-07-15
The red panda (Ailurus fulgens) is distributed primarily in the Himalayas and southern China. It is classified as a vulnerable species by the International Union for Conservation of Nature. The aim of this study was to describe the normal osteology and radiographic anatomy of the thoracic limb of the red panda. Radiography of the right thoracic limb was performed in seven captive adult red pandas. Radiographic findings were correlated with bone specimens from three adult animals. The scapula was wide craniocaudally and presented with a large area for the origin of the teres major muscle. The square-shaped major tubercle did not extend proximal to the head of the humerus. The medial epicondyle was prominent. A supracondylar foramen was present. The radial tuberosity and sesamoid bone for the abductor digiti I longus were prominent. The accessory carpal bone was directed palmarolaterally. Metacarpal bones were widely spread. The thoracic limb morphology of the red panda evidenced by osteology and radiography indicated flexibility of the thoracic limb joints and well-developed flexor and supinator muscles, which are important in arboreal quadrupedal locomotion. Knowledge gained during this study may prove useful in identifying skeletal material or remains and diagnosing musculoskeletal diseases and injuries of the thoracic limb.
Walker, V A; Tranquille, C A; Newton, J R; Dyson, S J; Brandham, J; Northrop, A J; Murray, R C
2017-09-01
Dressage horses are often asked to work in lengthened paces during training and competition, but to date there is limited information about the biomechanics of dressage-specific paces. Preliminary work has shown increased fetlock extension in extended compared with collected paces, but further investigation of the kinematic differences between collected, medium and extended trot in dressage horses is warranted. Investigation of the effect of collected vs. medium/extended trot on limb kinematics of dressage horses. Prospective kinematic evaluation. Twenty clinically sound horses in active dressage training were used. Group 1: Ten young horses (≤6 years) were assessed at collected and medium trot and Group 2: Ten mature horses (≥9 years) were assessed at collected and extended trot. All horses were evaluated on two different surfaces. High speed motion capture (240 Hz) was used to determine kinematic variables. Fore- and hindlimb angles were measured at mid-stance. Descriptive statistics and mixed effect multilevel regression analyses were performed. Speed and stride length were reduced and stride duration increased at collected compared with medium/extended trot. Lengthened trot (medium/extended trot) was associated with increased fetlock extension in both the fore- and hindlimbs in both groups of horses. Changes were greater in mature horses compared with young horses. Shoulder and carpus angles were associated with forelimb fetlock angle. Hock angle was not significantly influenced by pace. Surface had no effect on fetlock or hock angles. Only 2D motion analysis was carried out. Results may have differed in horses with more extreme gait characteristics. Medium/extended trot increases extension of the fore- and hindlimb fetlock joints compared with collected trot in both young and mature dressage horses, respectively. © 2017 EVJ Ltd.
Karakasiliotis, K; Thandiackal, R; Melo, K; Horvat, T; Mahabadi, N K; Tsitkov, S; Cabelguen, J M; Ijspeert, A J
2016-06-01
Robots are increasingly used as scientific tools to investigate animal locomotion. However, designing a robot that properly emulates the kinematic and dynamic properties of an animal is difficult because of the complexity of musculoskeletal systems and the limitations of current robotics technology. Here, we propose a design process that combines high-speed cineradiography, optimization, dynamic scaling, three-dimensional printing, high-end servomotors and a tailored dry-suit to construct Pleurobot: a salamander-like robot that closely mimics its biological counterpart, Pleurodeles waltl Our previous robots helped us test and confirm hypotheses on the interaction between the locomotor neuronal networks of the limbs and the spine to generate basic swimming and walking gaits. With Pleurobot, we demonstrate a design process that will enable studies of richer motor skills in salamanders. In particular, we are interested in how these richer motor skills can be obtained by extending our spinal cord models with the addition of more descending pathways and more detailed limb central pattern generator networks. Pleurobot is a dynamically scaled amphibious salamander robot with a large number of actuated degrees of freedom (DOFs: 27 in total). Because of our design process, the robot can capture most of the animal's DOFs and range of motion, especially at the limbs. We demonstrate the robot's abilities by imposing raw kinematic data, extracted from X-ray videos, to the robot's joints for basic locomotor behaviours in water and on land. The robot closely matches the behaviour of the animal in terms of relative forward speeds and lateral displacements. Ground reaction forces during walking also resemble those of the animal. Based on our results, we anticipate that future studies on richer motor skills in salamanders will highly benefit from Pleurobot's design. © 2016 The Author(s).
Karakasiliotis, K.; Thandiackal, R.; Melo, K.; Horvat, T.; Mahabadi, N. K.; Tsitkov, S.; Cabelguen, J. M.; Ijspeert, A. J.
2016-01-01
Robots are increasingly used as scientific tools to investigate animal locomotion. However, designing a robot that properly emulates the kinematic and dynamic properties of an animal is difficult because of the complexity of musculoskeletal systems and the limitations of current robotics technology. Here, we propose a design process that combines high-speed cineradiography, optimization, dynamic scaling, three-dimensional printing, high-end servomotors and a tailored dry-suit to construct Pleurobot: a salamander-like robot that closely mimics its biological counterpart, Pleurodeles waltl. Our previous robots helped us test and confirm hypotheses on the interaction between the locomotor neuronal networks of the limbs and the spine to generate basic swimming and walking gaits. With Pleurobot, we demonstrate a design process that will enable studies of richer motor skills in salamanders. In particular, we are interested in how these richer motor skills can be obtained by extending our spinal cord models with the addition of more descending pathways and more detailed limb central pattern generator networks. Pleurobot is a dynamically scaled amphibious salamander robot with a large number of actuated degrees of freedom (DOFs: 27 in total). Because of our design process, the robot can capture most of the animal's DOFs and range of motion, especially at the limbs. We demonstrate the robot's abilities by imposing raw kinematic data, extracted from X-ray videos, to the robot's joints for basic locomotor behaviours in water and on land. The robot closely matches the behaviour of the animal in terms of relative forward speeds and lateral displacements. Ground reaction forces during walking also resemble those of the animal. Based on our results, we anticipate that future studies on richer motor skills in salamanders will highly benefit from Pleurobot's design. PMID:27358276
Contribution to the anatomical nomenclature concerning upper limb anatomy.
Kachlik, David; Musil, Vladimir; Baca, Vaclav
2017-04-01
The aim of this article is to revise and extend the existing sections of Terminologia Anatomica dealing with the upper limb structures, which nomenclature belongs to its most neglected and not developing parts, and to justify the use of the proposed anatomical terms in the clinical practice, research, and education. A sample collected from own educational and research experience was matched in the main anatomical textbooks as well as old and recent anatomical journals and compared with four versions of the official Latin anatomical nomenclatures. The authors summarize here 145 terms, completed with their definitions or explanations, concerning both constant and variable (inconstant) morphological structures (bones, joints, muscles, vessels, and nerves) of the pectoral girdle, arm, cubital region, forearm, wrist, and hand, completed with some grammar remarks and several general terms. After a broad discussion on this topic, the Terminologia Anatomica should be revised and extend with the listed terms (or their equivalents).
NASA Technical Reports Server (NTRS)
Tomasko, M. G.; Zellner, B.; Martinek, S.; Gehrels, T.
1981-01-01
A total of 14 8 hour I.U.E. observing sessions resulted in 39 spectra of 11 asteroids and 9 solar type stars as well as 57 spectra at various locations on the disk of Jupiter. The Jupiter observations include a total of 5 center to limb series of spectra at various latitudes and a North South series along the central meridian. In the range from 2000-3000 A, the planet shows a striking decrease in brightness at latitudes greater than about 30 degrees, and exhibits limb brightening at low latitudes and limb darkening at high latitudes. Preliminary results indicate that about 6 km-amagats of clean hydrogen are required above a haze of absorbing aerosols to reproduce the limb brightening observed at 2500 A in the equatorial regions. At higher latitudes, the aerosols extend to even higher levels of the atmosphere. Comparison of the Jovian data with detailed model calculations and the analyses of the asteroid spectra are still in progress with other support.
Laferrier, Justin Z; McFarland, Lynne V; Boninger, Michael L; Cooper, Rory A; Reiber, Gayle E
2010-01-01
Returning wounded veterans and servicemembers to their highest level of function following traumatic injury is a priority of the Departments of Defense and Veterans Affairs. We surveyed 245 veterans from the Vietnam war and 226 servicemembers and veterans from Operation Iraqi Freedom/Operation Enduring Freedom (OIF/OEF) conflicts with at least one major traumatic lower-limb loss to determine their use of mobility assistive technology (AT) and patterns of limb abandonment. Prosthetic device use without wheelchair use is found in 50.5% of Vietnam and 42.8% of OIF/OEF groups. Prostheses and supplementary wheelchairs are used by Vietnam (32%) and OIF/OEF (53%) groups (p < 0.01). Exclusive wheelchair use is more frequent in the Vietnam group (18%) than in the OIF/OEF group (4.0%, p < 0.01). In Vietnam participants, multivariate analysis found that multiple-limb loss (adjusted odds ratio [AOR] = 14.5; 95% confidence interval [CI] 5.5-38.5), bilateral lower-limb loss (AOR = 12.7; 95% CI 6.2-26.1), and number of comorbidities (AOR = 1.3; 95% CI 1.2-1.5) are associated with increased likelihood of wheelchair use. In OIF/OEF participants, bilateral lower-limb loss (AOR = 29.8; 95% CI 11.0-80.7), multiple-limb loss (AOR = 16.3; 95% CI 3.1-85.3), cumulative trauma disorder (AOR = 2.4; 95% CI 1.2-4.9), and number of combat injuries (AOR = 1.4; 95% CI 1.2-1.7) are associated with wheelchair use. Combined use of different types of mobility ATs promotes improved rehabilitation and ability to function.
... the use of leading-edge technology such as robotics, tissue engineering, and nanotechnology to design and build ... advantage of the latest advances in computer and robotics technology. www.research.va.gov 23 va research ...
Using upper limb kinematics to assess cognitive deficits in people living with both HIV and stroke.
Bui, Kevin D; Rai, Roshan; Johnson, Michelle J
2017-07-01
In this study, we aim to explore ways to objectively assess cognitive deficits in the stroke and HIV/stroke populations, where cognitive and motor impairments can be hard to separate. Using an upper limb rehabilitation robot called the Haptic TheraDrive, we collect performance error scores and motor learning data on the impaired and unimpaired limb during a trajectory tracking task. We compare these data to clinical cognitive scores. The preliminary results suggest a possible relationship between unimpaired upper limb performance error and visuospatial/executive function cognitive domains, but more work needs to be done to further investigate this. The potential of using robot-assisted technologies to measure unimpaired limb kinematics as a tool to assess cognitive deficits would be useful to inform more effective rehabilitation strategies for HIV, stroke, and HIV/stroke populations.
Weiner, Kevin S.; Grill-Spector, Kalanit
2011-01-01
The prevailing view of human lateral occipitotemporal cortex (LOTC) organization suggests a single area selective for images of the human body (extrastriate body area, EBA) that highly overlaps with the human motion-selective complex (hMT+). Using functional magnetic resonance imaging with higher resolution (1.5mm voxels) than past studies (3–4mm voxels), we examined the fine-scale spatial organization of these activations relative to each other, as well as to visual field maps in LOTC. Rather than one contiguous EBA highly overlapping hMT+, results indicate three limb-selective activations organized in a crescent surrounding hMT+: (1) an activation posterior to hMT+ on the lateral occipital sulcus/middle occipital gyrus (LOS/MOG) overlapping the lower vertical meridian shared between visual field maps LO-2 and TO-1, (2) an activation anterior to hMT+ on the middle temporal gyrus (MTG) consistently overlapping the lower vertical meridian of TO-2 and extending outside presently defined visual field maps, and (3) an activation inferior to hMT+ on the inferotemporal gyrus (ITG) overlapping the parafoveal representation of the TO cluster. This crescent organization of limb-selective activations surrounding hMT+ is reproducible over a span of three years and is consistent across different image types used for localization. Further, these regions exhibit differential position properties: preference for contralateral image presentation decreases and preference for foveal presentation increases from the limb-selective LOS to the MTG. Finally, the relationship between limb-selective activations and visual field maps extends to the dorsal stream where a posterior IPS activation overlaps V7. Overall, our measurements demonstrate a series of LOTC limb-selective activations that 1) have separate anatomical and functional boundaries, 2) overlap distinct visual field maps, and 3) illustrate differential position properties. These findings indicate that category selectivity alone is an insufficient organization principle for defining brain areas. Instead, multiple properties are necessary in order to parcellate and understand the functional organization of high-level visual cortex. PMID:21439386
From LIMS to OMPS-LP: Limb Ozone Observations for Future Reanalyses
NASA Technical Reports Server (NTRS)
Wargan, K.; Kramarova, N.; Remsberg, E.; Coy, L.; Harvey, L.; Livesey, N.; Pawson, S.
2017-01-01
High vertical resolution and accuracy of ozone data from satellite-borne limb sounders has made them an invaluable tool in scientific studies of the middle and upper atmosphere. However, it was not until recently that these measurements were successfully incorporated in atmospheric reanalyses: of the major multidecadal reanalyses only ECMWF's (European Centre for Medium-Range Weather Forecasts') ERA (ECMWF Re-Analysis)-Interim/ERA5 and NASA's MERRA-2 (Modern-Era Retrospective Analysis for Research and Applications-2) use limb ozone data. Validation and comparison studies have demonstrated that the addition of observations from the Microwave Limb Sounder (MLS) on EOS (Earth Observing System) Aura greatly improved the quality of ozone fields in MERRA-2 making these assimilated data sets useful for scientific research. In this presentation, we will show the results of test experiments assimilating retrieved ozone from the Limb Infrared Monitor of the Stratosphere (LIMS, 1978/1979) and Ozone Mapping Profiler Suite Limb Profiler (OMPS-LP, 2012 to present). Our approach builds on the established assimilation methodology used for MLS in MERRA-2 and, in the case of OMPS-LP, extends the excellent record of MLS ozone assimilation into the post-EOS era in Earth observations. We will show case studies, discuss comparisons of the new experiments with MERRA-2, strategies for bias correction and the potential for combined assimilation of multiple limb ozone data types in future reanalyses for studies of multidecadal stratospheric ozone changes including trends.
1993-01-01
Directed outgrowth of neural processes must involve transmission of signals from the tips of filopodia to the central region of the growth cone. Here, we report on the distribution and dynamics of one possible element in this process, actin, in live growth cones which are reorienting in response to in situ guidance cues. In grasshopper embryonic limbs, pioneer growth cones respond to at least three types of guidance cues: a limb axis cue, intermediate target cells, and a circumferential band of epithelial cells. With time-lapse imaging of intracellularly injected rhodamine-phalloidin and rhodamine-actin, we monitored the distribution of actin during growth cone responses to these cues. In distal limb regions, accumulation of actin in filopodia and growth cone branches accompanies continued growth, while reduction of actin accompanies withdrawal. Where growth cones are reorienting to intermediate target cells, or along the circumferential epithelial band, actin selectively accumulates in the proximal regions of those filopodia that have contacted target cells or are extending along the band. Actin accumulations can be retrogradely transported along filopodia, and can extend into the central region of the growth cone. These results suggest that regulation and translocation of actin may be a significant element in growth cone steering. PMID:8227150
Reflections on the present and future of upper limb prostheses.
Farina, Dario; Amsüss, Sebastian
2016-01-01
Despite progress in research and media attention on active upper limb prostheses, presently the most common commercial upper limb prosthetic devices are not fundamentally different from solutions offered almost one century ago. Limited information transfer for both control and sensory-motor integration and challenges in socket technology have been major obstacles. By analysing the present state-of-the-art and academic achievements, we provide our opinion on the future of upper limb prostheses. We believe that surgical procedures for muscle reinnervation and osseointegration will become increasingly clinically relevant; muscle electrical signals will remain the main clinical means for prosthetic control; and chronic electrode implants, first in muscles (control), then in nerves (sensory feedback), will become viable clinical solutions. After decades of suspended clinically relevant progress, it is foreseeable that a new generation of upper limb prostheses will enter the market in the near future based on such advances, thereby offering substantial clinical benefit for patients.
Towards A Representation of Vertically Resolved Ozone Changes in Reanalyses
NASA Technical Reports Server (NTRS)
Pawson, Steven; Wargan, Krzysztof; Keller, Christoph; McCarty, Will; Coy, Larry
2017-01-01
The Solar Backscatter Ultraviolet Radiometer (SBUV) instruments on NASA and NOAA spacecraft provide a long-term record of total-column ozone and deep-layer partial columns since about 1980. These data have been carefully processed to extract long-term trends and offer a valuable resource for ozone monitoring. Studies assimilating limb-sounding observations in the Goddard Earth Observing System (GEOS) data assimilation system (DAS) demonstrate that vertical ozone gradients in the upper troposphere and lower stratosphere (UTLS) are much better represented than with the deep-layer SBUV observations. This is exemplified by the use of retrieved ozone from the EOS Microwave Limb Sounder (EOS-MLS) instrument in the MERRA-2 reanalysis, for the period after 2004. This study examines the potential for extending the use of limb-sounding observations at earlier times and into the future, so that future reanalyses may be more applicable to the study of long-term ozone changes.Historical data are available from NASA instruments: the Limb Infrared Monitor of the Stratosphere (LIMS: 1978-1979); the Upper Atmospheric Research Satellite (UARS: 1991-1995); Sounding of the Atmosphere using Broadband Emission Radiometry (SABER: 2000-onwards). For the post EOS-MLS period, the joint NASA-NOAA Ozone Monitoring and Profiling Suite Limb Profiler (OMPS-LP) instrument was launched on the Suomi-NPP platform in 201x and is planned for future platforms. This study will examine two aspects of these data pertaining to future reanalyses. First, the feasibility of merging the EOS-MLS and OMPS-LP instruments to provide a long-term record that extends beyond the potential lifetime of EOS-MLS. If feasible, this would allow for long-term monitoring of ozone recovery in a three-dimensional reanalysis context. Second, the skill of the GEOS DAS in ingesting historical data types will be investigated. Because these do not overlap with EOS-MLS, use will be made of system statistics and evaluation using independent datasets. Impacts of using a complete ozone chemistry module will also be considered.
NASA Technical Reports Server (NTRS)
2005-01-01
[figure removed for brevity, see original site] Annotated image of Tharsis Limb Cloud 7 September 2005 This composite of red and blue Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) daily global images acquired on 6 July 2005 shows an isolated water ice cloud extending more than 30 kilometers (more than 18 miles) above the martian surface. Clouds such as this are common in late spring over the terrain located southwest of the Arsia Mons volcano. Arsia Mons is the dark, oval feature near the limb, just to the left of the 'T' in the 'Tharsis Montes' label. The dark, nearly circular feature above the 'S' in 'Tharsis' is the volcano, Pavonis Mons, and the other dark circular feature, above and to the right of 's' in 'Montes,' is Ascraeus Mons. Illumination is from the left/lower left. Season: Northern Autumn/Southern SpringScattering Polarization in the Chromosphere
NASA Technical Reports Server (NTRS)
Keller, C. U.; Sheeley, N. R., Jr.
1999-01-01
Scattering polarization from the photosphere observed close to the solar limb has recently become of interest to study turbulent magnetic fields, abundances, and radiative transfer effects. We extend these studies by measuring the scattering polarization off the limb, i.e. in the chromosphere. However, instrumental effects are much more pronounced and more complicated than those affecting on-disk measurements. In particular, scattered light from the telescope mirrors leads to a new type of instrumental polarization that we describe in detail. The differences between the linearly polarized spectra on the disk and off the limb are often very substantial. Here we show the profiles of HeI D(sub 3), the OI triplet at 777 nm, and the Nal D lines. The change in the latter is in reasonable agreement with the recent modeling efforts of atomic polarization in the lower level by Landi Degl'Innocenti (1998).
Martínez-Abadías, Neus; Mateu, Roger; Niksic, Martina; Russo, Lucia; Sharpe, James
2016-01-01
How the genotype translates into the phenotype through development is critical to fully understand the evolution of phenotypes. We propose a novel approach to directly assess how changes in gene expression patterns are associated with changes in morphology using the limb as a case example. Our method combines molecular biology techniques, such as whole-mount in situ hybridization, with image and shape analysis, extending the use of Geometric Morphometrics to the analysis of nonanatomical shapes, such as gene expression domains. Elliptical Fourier and Procrustes-based semilandmark analyses were used to analyze the variation and covariation patterns of the limb bud shape with the expression patterns of two relevant genes for limb morphogenesis, Hoxa11 and Hoxa13. We devised a multiple thresholding method to semiautomatically segment gene domains at several expression levels in large samples of limb buds from C57Bl6 mouse embryos between 10 and 12 postfertilization days. Besides providing an accurate phenotyping tool to quantify the spatiotemporal dynamics of gene expression patterns within developing structures, our morphometric analyses revealed high, non-random, and gene-specific variation undergoing canalization during limb development. Our results demonstrate that Hoxa11 and Hoxa13, despite being paralogs with analogous functions in limb patterning, show clearly distinct dynamic patterns, both in shape and size, and are associated differently with the limb bud shape. The correspondence between our results and already well-established molecular processes underlying limb development confirms that this morphometric approach is a powerful tool to extract features of development regulating morphogenesis. Such multilevel analyses are promising in systems where not so much molecular information is available and will advance our understanding of the genotype–phenotype map. In systematics, this knowledge will increase our ability to infer how evolution modified a common developmental pattern to generate a wide diversity of morphologies, as in the vertebrate limb. PMID:26377442
TECHNOLOGICAL OPTIONS FOR ACID RAIN CONTROL
Discussed are acid rain control options available to the electric utility industry. They include coal switching, flue gas desulfurization, and such emerging lower cost technologies as Limestone Injection Multistage Burners (LIMB) and Advanced Silicate (ADVACATE), both developed ...
ERIC Educational Resources Information Center
Burton, Andrew M.; Liu, Hao; Battersby, Steven; Brown, David; Sherkat, Nasser; Standen, Penny; Walker, Marion
2011-01-01
Stroke is the main cause of long term disability worldwide. Of those surviving, more than half will fail to regain functional usage of their impaired upper limb. Typically stroke upper limb rehabilitation exercises consist of repeated movements, which when tracked can form the basis of inputs to games. This paper discusses two systems utilizing…
Device to monitor sock use in people using prosthetic limbs: technical report.
Sanders, Joan E; Murthy, Revathi; Cagle, John C; Allyn, Katheryn J; Phillips, Reid H; Otis, Brian P
2012-01-01
A device using radio frequency identification (RFID) technology was developed to continuously monitor sock use in people who use prosthetic limbs. RFID tags were placed on prosthetic socks worn by subjects with transtibial limb loss, and a high-frequency RFID reader and antenna were placed in a portable unit mounted to the outside of the prosthetic socket. Bench testing showed the device to have a maximum read range between 5.6 cm and 12.7 cm, depending on the RFID tag used. Testing in a laboratory setting on three participants with transtibial amputation showed that the device correctly monitored sock presence during sitting, standing, and walking activity when one or two socks were worn but was less reliable when more socks were used. Accurate detection was sensitive to orientation of the tag relative to the reader, presence of carbon fiber in the prosthetic socket, pistoning of the limb in the socket, and overlap among the tags. Use of ultra-high-frequency RFID may overcome these limitations. With improvements, the technology may prove useful to practitioners prescribing volume accommodation strategies for patients by providing information about sock use between clinical visits, including timing and consistency of daily sock-ply changes.
Technical Report: A device to monitor sock use on people using prosthetic limbs
Sanders, Joan; Murthy, Revathi; Cagle, John; Allyn, Katheryn; Phillips, Reid
2015-01-01
A device using radio frequency identification technology (RFID) was developed to continuously monitor sock use on people using prosthetic limbs. RFID tags were placed on prosthetic socks worn by subjects with transtibial limb loss, and a high-frequency (HF) RFID reader and antenna were placed in a portable unit mounted to the outside of the prosthetic socket. Bench testing showed the device to have a maximum read range between 5.6 cm and 12.7 cm, depending on the RFID tag used. Testing in a laboratory setting on three participants with transtibial amputation showed that the device correctly monitored sock presence during sitting, standing, and walking activity when one or two socks were worn but was less reliable when more socks were used. Accurate detection was sensitive to orientation of the tag relative to the reader, presence of carbon fiber in the prosthetic socket, pistoning of the limb in the socket, and overlap among the tags. Use of ultra high frequency (UHF) RFID may overcome these limitations. With improvements, the technology may prove useful to practitioners prescribing volume accommodation strategies for patients by providing information about sock use between clinical visits, including timing and consistency of daily sock ply changes. PMID:23341315
Tatla, Sandy K; Lohse, Keith R; Shirzad, Navid; Hoens, Alison M; Miller, Kimberly J; Holsti, Liisa; Virji-Babul, Naznin; Van der Loos, HF Machiel
2015-01-01
Background Digital technology is becoming an increasingly popular means of delivering meaningful therapy to individuals with neurological impairments. An understanding of clients’ technology use and their perspectives on incorporating technology into rehabilitation can provide researchers and designers with valuable information to inform development of technologies and technology-based rehabilitation programs. Objective This study was designed to establish the current use and perceptions of gaming, social media, and robotics technologies for rehabilitative purposes from the perspective of adults and children with upper limb impairments to identify barriers and enablers to their adoption and use. Methods We conducted three focus groups consisting of pediatric (n=7, mean age 11.0 years) and adult (n=8, mean age 60.8 years) participants with hemiparesis affecting their upper limb. We applied thematic analysis methods to the resulting data. Results We identified three key themes: (1) clients’ use of technology in everyday life and rehabilitation, (2) barriers to use, and (3) enablers to therapy. Participants had limited exposure to technology for therapeutic purposes, but all acknowledged the potential benefits in providing motivation and interest for the performance of repetitive task practice. Adult participants requested efficacious, simple, and easy-to-use technology for rehabilitation with programs that could be individualized for them and expressed that they wanted these programs to provide a motivating means of repeated practice of therapeutic movements. In contrast, pediatric participants emphasized a desire for technology for rehabilitation that offered opportunities for social interaction and interactive games involving their whole body and not only their affected limb. Perceived safety and privacy were concerns for both groups. Conclusions Our findings highlight that all participants were open to the integration of technology into rehabilitation. Adult participants were more pragmatically motivated by potential recovery gains, whereas pediatric participants were more intrinsically motivated by access to games. PMID:28582236
STS-107 Crew Interviews: Rick D. Husband, Commander
NASA Technical Reports Server (NTRS)
2002-01-01
STS-107 Commander Rick Husband is seen during this preflight interview, where he gives a quick overview of the mission before answering questions about his inspiration to become an astronaut and his career path. Husband outlines what his role in the mission will be, what training the crew received, what crew member responsibilities will be, particularly during launch and reentry, what day to day life will be like on an extended duration mission, and what science experiments are going to be conducted onboard. He discusses the following science experiments and instruments in detail: MEIDEX (Mediterranean Israeli Dust Experiment), SOLSE (Shuttle Ozone Limb Sounding Experiment, FREESTAR (Fast Reaction Enabling Science Technology and Research) and various student projects. Husband also touches on the importance of space research, the value of international cooperation, the reason for dual crew shifts on the mission and the role of crew members as research subjects.
Motor control and learning with lower-limb myoelectric control in amputees.
Alcaide-Aguirre, Ramses E; Morgenroth, David C; Ferris, Daniel P
2013-01-01
Advances in robotic technology have recently enabled the development of powered lower-limb prosthetic limbs. A major hurdle in developing commercially successful powered prostheses is the control interface. Myoelectric signals are one way for prosthetic users to provide feedforward volitional control of prosthesis mechanics. The goal of this study was to assess motor learning in people with lower-limb amputation using proportional myoelectric control from residual-limb muscles. We examined individuals with transtibial amputation and nondisabled controls performing tracking tasks of a virtual object. We assessed how quickly the individuals with amputation improved their performance and whether years since amputation correlated with performance. At the beginning of training, subjects with amputation performed much worse than control subjects. By the end of a short training period, tracking error did not significantly differ between subjects with amputation and nondisabled subjects. Initial but not final performance correlated significantly with time since amputation. This study demonstrates that although subjects with amputation may initially have poor volitional control of their residual lower-limb muscles, training can substantially improve their volitional control. These findings are encouraging for the future use of proportional myoelectric control of powered lower-limb prostheses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandini, Roberto; Pipitone, Vincenzo; Stefanini, Matteo
The purpose of this study was to describe the efficacy of planned combined subintimal arterial flossing with antegrade-retrograde intervention (SAFARI) to obtain the precise recanalization of the patent portion of a distal runoff vessel in critical limb ischemia (CLI) patients presenting long occlusions involving the popliteal trifurcation. Four patients at risk of limb loss due to long occlusions involving the leg vessel tree and not suitable for a surgical bypass were treated by the subintimal antegrade and retrograde (posterior tibial or anterior tibial artery) approach. The patent portion of the runoff vessel was previously assessed by magnetic resonance angiography (MRA)more » and directly punctured under Doppler ultrasound (US) guidance. A subintimal channel rendezvous was performed to allow snaring of the guidewires. Subsequently, a balloon dilatation was performed without stent deployment. All patients were successfully recanalized and had complete healing of the limb lesions. At the 12-month follow-up all patients showed clinical improvement with no major complications related to the procedure. This combined antegrade and retrograde subintimal approach is currently an excellent endovascular option in patients with long occlusions extending onto the leg vessels trifurcation and at risk of limb loss.« less
Running over rough terrain reveals limb control for intrinsic stability.
Daley, Monica A; Biewener, Andrew A
2006-10-17
Legged animals routinely negotiate rough, unpredictable terrain with agility and stability that outmatches any human-built machine. Yet, we know surprisingly little about how animals accomplish this. Current knowledge is largely limited to studies of steady movement. These studies have revealed fundamental mechanisms used by terrestrial animals for steady locomotion. However, it is unclear whether these models provide an appropriate framework for the neuromuscular and mechanical strategies used to achieve dynamic stability over rough terrain. Perturbation experiments shed light on this issue, revealing the interplay between mechanics and neuromuscular control. We measured limb mechanics of helmeted guinea fowl (Numida meleagris) running over an unexpected drop in terrain, comparing their response to predictions of the mass-spring running model. Adjustment of limb contact angle explains 80% of the variation in stance-phase limb loading following the perturbation. Surprisingly, although limb stiffness varies dramatically, it does not influence the response. This result agrees with a mass-spring model, although it differs from previous findings on humans running over surfaces of varying compliance. However, guinea fowl sometimes deviate from mass-spring dynamics through posture-dependent work performance of the limb, leading to substantial energy absorption following the perturbation. This posture-dependent actuation allows the animal to absorb energy and maintain desired velocity on a sudden substrate drop. Thus, posture-dependent work performance of the limb provides inherent velocity control over rough terrain. These findings highlight how simple mechanical models extend to unsteady conditions, providing fundamental insights into neuromuscular control of movement and the design of dynamically stable legged robots and prosthetic devices.
Alimentary Limb Ischemia During Roux-en-Y Gastric Bypass and its Management.
Mittal, Tarun; Dey, Ashish; Nali, Abhilash; Taha Mustafa, Sheikh Mohammad; Malik, Vinod K
2018-05-01
Ischemia of the tip of the alimentary limb involving the gastrojejunostomy (GJ) is an unusual complication during Roux-en-Y gastric bypass (RYGB). Revision of the GJ may be needed to manage this complication. We present a case of inadvertent perforation of the jejunum by a gastric calibration tube, which was recognized on the table and appropriate measures are then taken. Repair of this enterotomy however then led to ischemia of the tip of alimentary limb extending to a portion of the GJ anastomosis. We present its subsequent management. Our patient is a morbidly obese female patient with a BMI value of 44.6 kg/msq undergoing RYGB. We performed an antecolic, antegastric linear-stapled gastrojejunostomy of 2.5 cm. After hand-sewn closure of the common enterotomy, we tried passing a 38-F Bougie through the anastomosis into the Roux limb. During this maneuver, the Bougie inadvertently perforated the Roux limb at the mesenteric border. Following the repair of this jejunal rent, the distal part of the Roux limb became dusky and involved a portion of the gastrojejunal anastomosis. The gastrojejunostomy was therefore completely revised. Intraoperatively, methylene blue dye test was done which showed no leak. Post-operative gastrografin study revealed no leak and liquids were started on POD1. Inadvertent injury by a Bougie is a rare but known complication in laparoscopic RYGB. Intraoperative recognition of the complication is essential to prompt the necessary repair. Revision of the gastrojejunostomy is necessary if the Roux limb or the anastomosis itself is ischemic and can be accomplished with good results.
Hunt, Gene; Park, Lisa E; Labarbera, Michael
2007-02-01
Despite the diversity and ecological importance of cypridoidean ostracodes, there have been no kinematic studies of how they swim. We used regular and high-speed video of tethered ostracodes to document locomotion in the cypridoidean species Cypridopsis vidua. Swimming in this species is drag-based, with thrust provided by both antennulae and antennae. About 15 complete power and recovery strokes occur per second; maximal speeds for the limb tips were about 30 mm/s for the antennulae and 50 mm/s for the antennae. These speeds correspond to Reynolds numbers on the order of 10(-1) to 10(0) for the limb tips and 10(-2) to 10(-1) for the setae that extend outward from the swimming limbs and provide much of the surface area of the limb. The strokes of the four thrust-producing limbs are coordinated in a manner that seems to be unique among aquatic arthropods. When viewed from the anterior, power strokes are synchronized diagonally: left antennula and right antenna power strokes start at the same time and terminate just as the power strokes for the right antennula and left antenna begin. Because power strokes occur throughout the stroke cycle, swimming in this species is smoothly continuous, without the rapid accelerations and decelerations characteristic of most small aquatic arthropods.
Development of BION(TM) Technology for Functional Electrical Stimulation: Bidirectional Telemetry
2001-10-25
paralyzed limb , it is necessary to incorporate sensors and back telemetry to provide voluntary control and sensory feedback signals. We describe...requirements. Keywords - neural prostheses, electrical stimulation, implants, telemetry, sensors I. INTRODUCTION BIONs ( BIOnic Neurons) are modular...ents of a paralyzed limb will require a sophisticated control system that must be driven by two types of data from the patient: 1) command signals
Hybrid robotic systems for upper limb rehabilitation after stroke: A review.
Resquín, Francisco; Cuesta Gómez, Alicia; Gonzalez-Vargas, Jose; Brunetti, Fernando; Torricelli, Diego; Molina Rueda, Francisco; Cano de la Cuerda, Roberto; Miangolarra, Juan Carlos; Pons, José Luis
2016-11-01
In recent years the combined use of functional electrical stimulation (FES) and robotic devices, called hybrid robotic rehabilitation systems, has emerged as a promising approach for rehabilitation of lower and upper limb motor functions. This paper presents a review of the state of the art of current hybrid robotic solutions for upper limb rehabilitation after stroke. For this aim, studies have been selected through a search using web databases: IEEE-Xplore, Scopus and PubMed. A total of 10 different hybrid robotic systems were identified, and they are presented in this paper. Selected systems are critically compared considering their technological components and aspects that form part of the hybrid robotic solution, the proposed control strategies that have been implemented, as well as the current technological challenges in this topic. Additionally, we will present and discuss the corresponding evidences on the effectiveness of these hybrid robotic therapies. The review also discusses the future trends in this field. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Fallavollita, Pascal; Brand, Alexander; Wang, Lejing; Euler, Ekkehard; Thaller, Peter; Navab, Nassir; Weidert, Simon
2016-11-01
Determination of lower limb alignment is a prerequisite for successful orthopedic surgical treatment. Traditional methods include the electrocautery cord, alignment rod, or axis board which rely solely on C-arm fluoroscopy navigation and are radiation intensive. To assess a new augmented reality technology in determining lower limb alignment. A camera-augmented mobile C-arm (CamC) technology was used to create a panorama image consisting of hip, knee, and ankle X-rays. Twenty-five human cadaver legs were used for validation with random varus or valgus deformations. Five clinicians performed experiments that consisted in achieving acceptable mechanical axis deviation. The applicability of the CamC technology was assessed with direct comparison to ground-truth CT. A t test, Pearson's correlation, and ANOVA were used to determine statistical significance. The value of Pearson's correlation coefficient R was 0.979 which demonstrates a strong positive correlation between the CamC and ground-truth CT data. The analysis of variance produced a p value equal to 0.911 signifying that clinician expertise differences were not significant with regard to the type of system used to assess mechanical axis deviation. All described measurements demonstrated valid measurement of lower limb alignment. With minimal effort, clinicians required only 3 X-ray image acquisitions using the augmented reality technology to achieve reliable mechanical axis deviation.
Volcanic Plume from Mt. Unzen, Dust Cloud, cloud Vortices
1991-12-01
Stable, south flowing air over the western Pacific Ocean (26.0N, 131.0E) is disturbed by islands south of Korea, resulting in sinuous clouds known as von Karman vortices. The smoke plume from Japan's Mount Unzen Volcano on Kyushu, is visible just west of the large cloud mass and extending southward. A very large, purple tinged dust pall, originating in Mongolia, can be seen on the Earth's Limb, covering eastern China and extending into the East China Sea.
Horn, G
1997-12-01
The Frechet extender, initially proposed and successfully used in scalp reductions, can have many other indications in reconstructive surgery. This paper describes the preliminary results obtained after using this internal tissue extender in the treatment of a limb burn scar and a congenital giant naevus of the back. After a 3 month follow-up, these results are excellent. This procedure gives good results especially when there is a bony support underneath the skin to be treated.
He, Yongtian; Nathan, Kevin; Venkatakrishnan, Anusha; Rovekamp, Roger; Beck, Christopher; Ozdemir, Recep; Francisco, Gerard E; Contreras-Vidal, Jose L
2014-01-01
Stroke remains a leading cause of disability, limiting independent ambulation in survivors, and consequently affecting quality of life (QOL). Recent technological advances in neural interfacing with robotic rehabilitation devices are promising in the context of gait rehabilitation. Here, the X1, NASA's powered robotic lower limb exoskeleton, is introduced as a potential diagnostic, assistive, and therapeutic tool for stroke rehabilitation. Additionally, the feasibility of decoding lower limb joint kinematics and kinetics during walking with the X1 from scalp electroencephalographic (EEG) signals--the first step towards the development of a brain-machine interface (BMI) system to the X1 exoskeleton--is demonstrated.
Exoskeleton robots for upper-limb rehabilitation: state of the art and future prospects.
Lo, Ho Shing; Xie, Sheng Quan
2012-04-01
Current health services are struggling to provide optimal rehabilitation therapy to victims of stroke. This has motivated researchers to explore the use of robotic devices to provide rehabilitation therapy for strokepatients. This paper reviews the recent progress of upper limb exoskeleton robots for rehabilitation treatment of patients with neuromuscular disorders. Firstly, a brief introduction to rehabilitation robots will be given along with examples of existing commercial devices. The advancements in upper limb exoskeleton technology and the fundamental challenges in developing these devices are described. Potential areas for future research are discussed. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Hildred, W.
1973-01-01
The transfer of NASA technolgy to rehabilitative applications of artificial limbs is studied. Human factors engineering activities range from orthotic manipulators to tiny dc motors and transducers to detect and transmit voluntary control signals. It is found that bicarbon implant devices are suitable for medical equipment and artificial limbs because of their biological compatibility with human body fluids and tissues.
Sun, Runjie; Tian, Liang; Fang, Xiaoli; Du, Xiaozheng; Zhu, Bowen; Song, Zhongyang; Xu, Xuan; Qin, Xiaoguang
2017-04-12
To compare the difference in the clinical efficacy on post-stroke upper limb spasmodic hemiplegia between the combined therapy of jingou diaoyu needling technique and Bobath technology and simple Bobath technology. Sixty patients were randomized into an observation group and a control group, 30 cases in each one. The usual medication of neurological internal medicine was used in the two groups. In the control group, Bobath facilitation technology was applied to the rehabilitation training. In the observation group, on the basis of the treatment as the control group, jingou diaoyu needling technique was used to stimulate Zhongfu (LU 1), Tianfu (LU 3), Chize (LU 5), Quchi (LI 11), Jianshi (PC 5) and Daling (PC 7). The treatment was given once a day; 5 treatments made one session and totally 4-week treatment was required in the two groups. The modified Ashworth scale, the modified Fugle-Meyer assessment (FMA) and the Barthel index (BI) were adopted to evaluate the muscular tension, the upper limb motor function and the activities of daily living (ADL) before and after treatment in the two groups. The clinical efficacy was compared between the two groups. Compared with those before treatment, the modified Ashworth scale, Fugl-Meyer score and BI score were all improved after treatment in the two groups (all P <0.01). The results in the observation group were better than those in the control group (all P <0.01). The total clinical effective rate was 93.3% (28/30) in the observation group and was 80.0% (24/30) in the control group. The efficacy in the observation group was better than that in the control group ( P <0.05). The jingou diaoyu needling technique combined with Bobath therapy achieve the superior efficacy on post-stroke upper limb spasmodic hemiplegia as compared with the simple application Bobath therapy. This combined treatment effectively relieve spasmodic state and improve the upper limb motor function and the activities of daily living.
Progressive upper limb prosthetics.
Lake, Chris; Dodson, Robert
2006-02-01
The field of upper extremity prosthetics is a constantly changing arena as researchers and prosthetists strive to bridge the gap between prosthetic reality and upper limb physiology. With the further development of implantable neurologic sensing devices and targeted muscle innervation (discussed elsewhere in this issue), the challenge of limited input to control vast outputs promises to become a historical footnote in the future annals of upper limb prosthetics. Soon multidextrous terminal devices, such as that found in the iLimb system(Touch EMAS, Inc., Edinburgh, UK), will be a clinical reality (Fig. 22). Successful prosthetic care depends on good communication and cooperation among the surgeon, the amputee, the rehabilitation team, and the scientists harnessing the power of technology to solve real-life challenges. If the progress to date is any indication, amputees of the future will find their dreams limited only by their imagination.
Amputation rehabilitation and prosthetic restoration. From surgery to community reintegration.
Esquenazi, Alberto
The purpose of this review is to summarize the literature related to the advances that have taken place in the management and rehabilitation care of limb amputation. Prostheses for the lower and upper limb amputee have changed greatly over the past several years, with advances in components, socket fabrication and fitting techniques, suspension systems and sources of power and electronic controls. Higher levels of limb amputation can now be fitted with functional prostheses, which allow more patients to achieve independent life styles. This is of particular importance for the multi-limb amputee. The rehabilitation of more traditional lower limb levels of amputation have also greatly benefited from the technological advances including energy storing feet, electronic control hydraulic knees, ankle rotators and shock absorbers to mention a few. For the upper limb amputee, myoelectric and proportional controlled terminal devices and elbow joints are now used routinely in some rehabilitation facilities. Experimental prosthetic fitting techniques and devices such as the use of osseo-implantation for suspension of the prosthesis, tension control hands or electromagnetic fluids for knee movement control will also be briefly discussed in this paper. It is possible to conclude from this review that many advances have occurred that have greatly impacted the functional outcomes of patients with limb amputation.
How do sock ply changes affect residual-limb fluid volume in people with transtibial amputation?
Sanders, Joan E; Harrison, Daniel S; Allyn, Katheryn J; Myers, Timothy R; Ciol, Marcia A; Tsai, Elaine C
2012-01-01
The purpose of this research was to investigate the influence of sock addition and removal on residual-limb fluid volume in people using prosthetic limbs. We used bioimpedance analysis to measure residual-limb extracellular fluid volume on 28 transtibial amputee subjects during 30 min test sessions. Upon addition of a one-ply polyester sock, residual-limb fluid volume changes ranged from -4.0% to 0.8% (mean -0.9 +/- 1.3%) of the initial limb fluid volume. Changes for sock removal ranged from -1.2% to 2.8% (mean 0.5 +/- 0.8%). Subjects who reduced in fluid volume with both addition and removal of a sock and subjects with high positive ratios between the fluid-volume loss upon sock addition and gain upon sock removal (high add/remove [AR] ratios) tended to have arterial disease, were obese, and were smokers. Subjects with low positive AR ratios, subjects who increased in fluid volume both with sock addition and removal, and a single subject who increased in fluid volume with sock addition and decreased with sock removal tended to be nonsmokers and either individuals in good health without complications or individuals without arterial problems. Results are relevant for the anticipation of limb volume changes during prosthetic fitting and toward the design of adjustable-socket technologies.
On the Inclusion of Externally Controlled Actions in Action Planning
ERIC Educational Resources Information Center
Tsai, Jessica Chia-Chin; Knoblich, Gunther; Sebanz, Natalie
2011-01-01
According to ideomotor theories, perceiving action effects produced by others triggers corresponding action representations in the observer. We tested whether this principle extends to actions performed by externally controlled limbs and tools. Participants performed a go-no-go version of a spatial compatibility task in which their own actions…
Ubiquitous human upper-limb motion estimation using wearable sensors.
Zhang, Zhi-Qiang; Wong, Wai-Choong; Wu, Jian-Kang
2011-07-01
Human motion capture technologies have been widely used in a wide spectrum of applications, including interactive game and learning, animation, film special effects, health care, navigation, and so on. The existing human motion capture techniques, which use structured multiple high-resolution cameras in a dedicated studio, are complicated and expensive. With the rapid development of microsensors-on-chip, human motion capture using wearable microsensors has become an active research topic. Because of the agility in movement, upper-limb motion estimation has been regarded as the most difficult problem in human motion capture. In this paper, we take the upper limb as our research subject and propose a novel ubiquitous upper-limb motion estimation algorithm, which concentrates on modeling the relationship between upper-arm movement and forearm movement. A link structure with 5 degrees of freedom (DOF) is proposed to model the human upper-limb skeleton structure. Parameters are defined according to Denavit-Hartenberg convention, forward kinematics equations are derived, and an unscented Kalman filter is deployed to estimate the defined parameters. The experimental results have shown that the proposed upper-limb motion capture and analysis algorithm outperforms other fusion methods and provides accurate results in comparison to the BTS optical motion tracker.
Defense Advanced Research Projects Agency Strategic Plan
2007-02-01
be able to feel objects that are being grasped so that the prosthesis is experienced as an arm instead of as a tool; and (iii) development of...instrument, but also the ability to sense an artificial limb’s position without looking at it, and to actually " feel " precisely what the artificial limb...is touching by relaying sensations through residual nerves. (This program is also leveraging developments in a core technology program, Human Assisted
ATHLETE: Lunar Cargo Unloading from a High Deck
NASA Technical Reports Server (NTRS)
Wilcox, Brian H.
2010-01-01
As part of the NASA Exploration Technology Development Program, the Jet Propulsion Laboratory is developing a vehicle called ATHLETE: the All-Terrain Hex-Limbed Extra-Terrestrial Explorer. Each vehicle is based on six wheels at the ends of six multi-degree-of freedom limbs. Because each limb has enough degrees of freedom for use as a general-purpose leg, the wheels can be locked and used as feet to walk out of excessively soft or other extreme terrain. Since the vehicle has this alternative mode of traversing through or at least out of extreme terrain, the wheels and wheel actuators can be sized for nominal terrain. There are substantial mass savings in the wheel and wheel actuators associated with designing for nominal instead of extreme terrain. These mass savings are at least comparable-to or larger-than the extra mass associated with the articulated limbs. As a result, the entire mobility system, including wheels and limbs, can be lighter than a conventional all-terrain mobility chassis. A side benefit of this approach is that each limb has sufficient degrees-of freedom to be used as a general-purpose manipulator (hence the name "limb" instead of "leg"). Our prototype ATHLETE vehicles have quick-disconnect tool adapters on the limbs that allow tools to be drawn out of a "tool belt" and maneuvered by the limb. A power-take-off from the wheel actuates the tools, so that they can take advantage of the 1+ horsepower motor in each wheel to enable drilling, gripping or other power-tool functions.
ATHLETE: a Cargo and Habitat Transporter for the Moon
NASA Technical Reports Server (NTRS)
Wilcox, Brian H.
2009-01-01
As part of the NASA Exploration Technology Development Program, the Jet Propulsion Laboratory is developing a vehicle called ATHLETE: the All-Terrain Hex-Limbed Extra-Terrestrial Explorer. The vehicle concept is based on six wheels at the ends of six multi-degree-of-freedom limbs. Because each limb has enough degrees of freedom for use as a general-purpose leg, the wheels can be locked and used as feet to walk out of excessively soft or other extreme terrain. Since the vehicle has this alternative mode of traversing through (or at least out of) extreme terrain, the wheels and wheel actuators can be sized only for nominal terrain. There are substantial mass savings in the wheels and wheel actuators associated with designing for nominal instead of extreme terrain. These mass savings are comparable-to or larger-than the extra mass associated with the articulated limbs. As a result, the entire mobility system, including wheels and limbs, can be about 25 percent lighter than a conventional mobility chassis for planetary exploration. A side benefit of this approach is that each limb has sufficient degrees-of-freedom for use as a general-purpose manipulator (hence the name "limb" instead of "leg"). Our prototype ATHLETE vehicles have quick-disconnect tool adapters on the limbs that allow tools to be drawn out of a "tool belt" and maneuvered by the limb. A rotating power-take-off from the wheel actuates the tools, so that they can take advantage of the 1-plus-horsepower motor in each wheel to enable drilling, gripping or other power-tool functions.
The influence of relative body breadth on the diaphyseal morphology of the human lower limb.
Davies, Thomas G; Stock, Jay T
2014-01-01
Variation in relative body breadth between individuals is potentially a significant influence on the biomechanical loading placed upon the lower limb. This study investigates the influence of relative body breadth on the periosteal geometry of the diaphyses of the limb bones among individuals from a broad range of human populations. This study applies a 3D laser scanning approach to the extraction and analysis of periosteal cross-sectional properties throughout the diaphyses of the femur and tibia to test for influences of body shape on diaphyseal morphology throughout the lower limb. Analyses are based on data collected from seven populations, encompassing a broad range of modern human variation in body shape. Hypertrophy of the proximal end of the femur diaphysis in wider bodied individuals is observed and appears to extend at least as far as the femur midshaft, while the mid diaphyseal region of the tibia is the least influenced by body shape. However correlations with relative body breadth were also observed towards the distal end of the femur diaphysis and towards both ends of the tibial diaphysis, especially among females. Relative body breadth is correlated with the periosteal geometry of the lower limb bones, particularly towards the proximal end of the femur diaphysis, but correlations in other regions also suggest integration of the diaphyseal geometry with epiphyseal dimensions. © 2014 Wiley Periodicals, Inc.
Cortés, Camilo; de Los Reyes-Guzmán, Ana; Scorza, Davide; Bertelsen, Álvaro; Carrasco, Eduardo; Gil-Agudo, Ángel; Ruiz-Salguero, Oscar; Flórez, Julián
2016-01-01
Robot-Assisted Rehabilitation (RAR) is relevant for treating patients affected by nervous system injuries (e.g., stroke and spinal cord injury). The accurate estimation of the joint angles of the patient limbs in RAR is critical to assess the patient improvement. The economical prevalent method to estimate the patient posture in Exoskeleton-based RAR is to approximate the limb joint angles with the ones of the Exoskeleton. This approximation is rough since their kinematic structures differ. Motion capture systems (MOCAPs) can improve the estimations, at the expenses of a considerable overload of the therapy setup. Alternatively, the Extended Inverse Kinematics Posture Estimation (EIKPE) computational method models the limb and Exoskeleton as differing parallel kinematic chains. EIKPE has been tested with single DOF movements of the wrist and elbow joints. This paper presents the assessment of EIKPE with elbow-shoulder compound movements (i.e., object prehension). Ground-truth for estimation assessment is obtained from an optical MOCAP (not intended for the treatment stage). The assessment shows EIKPE rendering a good numerical approximation of the actual posture during the compound movement execution, especially for the shoulder joint angles. This work opens the horizon for clinical studies with patient groups, Exoskeleton models, and movements types.
Aversi-Ferreira, Roqueline A. G. M. F.; de Abreu, Tainá; Pfrimer, Gabriel A.; Silva, Sylla F.; Ziermann, Janine M.; Carneiro-e-Silva, Frederico O.; Tomaz, Carlos; Tavares, Maria Clotilde H.; Maior, Rafael S.; Aversi-Ferreira, Tales A.
2013-01-01
Capuchin monkeys are known to exhibit sporadic bipedalism while performing specific tasks, such as cracking nuts. The bipedal posture and locomotion cause an increase in the metabolic cost and therefore increased blood supply to lower limbs is necessary. Here, we present a detailed anatomical description of the capuchin arteries and veins of the pelvic limb of Sapajus libidinosus in comparison with other primates. The arterial pattern of the bearded capuchin hind limb is more similar to other quadrupedal Cebus species. Similarities were also found to the pattern observed in the quadruped Papio, which is probably due to a comparable pelvis and the presence of the tail. Sapajus' traits show fewer similarities when compared to great apes and modern humans. Moreover, the bearded capuchin showed unique patterns for the femoral and the short saphenous veins. Although this species switches easily from quadrupedal to bipedal postures, our results indicate that the bearded capuchin has no specific or differential features that support extended bipedal posture and locomotion. Thus, the explanation for the behavioral differences found among capuchin genera probably includes other aspects of their physiology. PMID:24396829
Aversi-Ferreira, Roqueline A G M F; de Abreu, Tainá; Pfrimer, Gabriel A; Silva, Sylla F; Ziermann, Janine M; Carneiro-E-Silva, Frederico O; Tomaz, Carlos; Tavares, Maria Clotilde H; Maior, Rafael S; Aversi-Ferreira, Tales A
2013-01-01
Capuchin monkeys are known to exhibit sporadic bipedalism while performing specific tasks, such as cracking nuts. The bipedal posture and locomotion cause an increase in the metabolic cost and therefore increased blood supply to lower limbs is necessary. Here, we present a detailed anatomical description of the capuchin arteries and veins of the pelvic limb of Sapajus libidinosus in comparison with other primates. The arterial pattern of the bearded capuchin hind limb is more similar to other quadrupedal Cebus species. Similarities were also found to the pattern observed in the quadruped Papio, which is probably due to a comparable pelvis and the presence of the tail. Sapajus' traits show fewer similarities when compared to great apes and modern humans. Moreover, the bearded capuchin showed unique patterns for the femoral and the short saphenous veins. Although this species switches easily from quadrupedal to bipedal postures, our results indicate that the bearded capuchin has no specific or differential features that support extended bipedal posture and locomotion. Thus, the explanation for the behavioral differences found among capuchin genera probably includes other aspects of their physiology.
Vascular access in critical limb ischemia.
Kang, Won Yu; Campia, Umberto; Ota, Hideaki; Didier, Romain J; Negi, Smita I; Kiramijyan, Sarkis; Koifman, Edward; Baker, Nevin C; Magalhaes, Marco A; Lipinski, Michael J; Escarcega, Ricardo O; Torguson, Rebecca; Waksman, Ron; Bernardo, Nelson L
2016-01-01
Currently, percutaneous endovascular intervention is considered a first line of therapy for treating patients with critical limb ischemia. As the result of remarkable development of techniques and technologies, percutaneous endovascular intervention has led to rates of limb salvage comparable to those achieved with bypass surgery, with fewer complications, even in the presence of lower rates of long-term patency. Currently, interventionalists have a multiplicity of access routes including smaller arteries, with both antegrade and retrograde approaches. Therefore, the choice of the optimal access site has become an integral part of the success of the percutaneous intervention. By understanding the technical aspects, as well as the advantages and limitations of each approach, the interventionalists can improve clinical outcomes in patients with severe peripheral arterial disease. This article reviews the access routes in critical limb ischemia, their advantages and disadvantages, and the clinical outcomes of each. Copyright © 2016 Elsevier Inc. All rights reserved.
Powell, Lauren; Parker, Jack; Martyn St-James, Marrissa; Mawson, Susan
2016-10-07
With advances in technology, the adoption of wearable devices has become a viable adjunct in poststroke rehabilitation. Regaining ambulation is a top priority for an increasing number of stroke survivors. However, despite an increase in research exploring these devices for lower limb rehabilitation, little is known of the effectiveness. This review aims to assess the effectiveness of lower limb wearable technology for improving activity and participation in adult stroke survivors. Randomized controlled trials (RCTs) of lower limb wearable technology for poststroke rehabilitation were included. Primary outcome measures were validated measures of activity and participation as defined by the International Classification of Functioning, Disability and Health. Databases searched were MEDLINE, Web of Science (Core collection), CINAHL, and the Cochrane Library. The Cochrane Risk of Bias Tool was used to assess the methodological quality of the RCTs. In the review, we included 11 RCTs with collectively 550 participants at baseline and 474 participants at final follow-up including control groups and participants post stroke. Participants' stroke type and severity varied. Only one study found significant between-group differences for systems functioning and activity. Across the included RCTs, the lowest number of participants was 12 and the highest was 151 with a mean of 49 participants. The lowest number of participants to drop out of an RCT was zero in two of the studies and 19 in one study. Significant between-group differences were found across three of the 11 included trials. Out of the activity and participation measures alone, P values ranged from P=.87 to P ≤.001. This review has highlighted a number of reasons for insignificant findings in this area including low sample sizes, appropriateness of the RCT methodology for complex interventions, a lack of appropriate analysis of outcome data, and participant stroke severity.
Parker, Jack; Martyn St-James, Marrissa; Mawson, Susan
2016-01-01
Background With advances in technology, the adoption of wearable devices has become a viable adjunct in poststroke rehabilitation. Regaining ambulation is a top priority for an increasing number of stroke survivors. However, despite an increase in research exploring these devices for lower limb rehabilitation, little is known of the effectiveness. Objective This review aims to assess the effectiveness of lower limb wearable technology for improving activity and participation in adult stroke survivors. Methods Randomized controlled trials (RCTs) of lower limb wearable technology for poststroke rehabilitation were included. Primary outcome measures were validated measures of activity and participation as defined by the International Classification of Functioning, Disability and Health. Databases searched were MEDLINE, Web of Science (Core collection), CINAHL, and the Cochrane Library. The Cochrane Risk of Bias Tool was used to assess the methodological quality of the RCTs. Results In the review, we included 11 RCTs with collectively 550 participants at baseline and 474 participants at final follow-up including control groups and participants post stroke. Participants' stroke type and severity varied. Only one study found significant between-group differences for systems functioning and activity. Across the included RCTs, the lowest number of participants was 12 and the highest was 151 with a mean of 49 participants. The lowest number of participants to drop out of an RCT was zero in two of the studies and 19 in one study. Significant between-group differences were found across three of the 11 included trials. Out of the activity and participation measures alone, P values ranged from P=.87 to P ≤.001. Conclusions This review has highlighted a number of reasons for insignificant findings in this area including low sample sizes, appropriateness of the RCT methodology for complex interventions, a lack of appropriate analysis of outcome data, and participant stroke severity. PMID:27717920
Design and analysis of an underactuated anthropomorphic finger for upper limb prosthetics.
Omarkulov, Nurdos; Telegenov, Kuat; Zeinullin, Maralbek; Begalinova, Ainur; Shintemirov, Almas
2015-01-01
This paper presents the design of a linkage based finger mechanism ensuring extended range of anthropomorphic gripping motions. The finger design is done using a path-point generation method based on geometrical dimensions and motion of a typical index human finger. Following the design description, and its kinematics analysis, the experimental evaluation of the finger gripping performance is presented using the finger 3D printed prototype. The finger underactuation is achieved by utilizing mechanical linkage system, consisting of two crossed four-bar linkage mechanisms. It is shown that the proposed finger design can be used to design a five-fingered anthropomorphic hand and has the potential for upper limb prostheses development.
Can an ankle-foot orthosis change hearts and minds?
Patzkowski, Jeanne C; Blanck, Ryan V; Owens, Johnny G; Wilken, Jason M; Blair, James A; Hsu, Joseph R
2011-01-01
The current military conflicts of Operation Enduring Freedom and Operation Iraqi Freedom have been characterized by high-energy explosive wounding patterns, with the majority affecting the extremities. While many injuries have resulted in amputation, surgical advances have allowed the orthopaedic surgeon to pursue limb salvage in the face of injuries once considered unsalvageable. The military limb salvage patient is frequently highly active and motivated and expresses significant frustration with the slow nature of limb salvage rehabilitation and continued functional deficits. Inspired by these patients, efforts at this institution began to provide them with a more dynamic orthosis. Utilizing techniques and technology resulting from cerebral palsy, stroke, and amputation research, the Intrepid Dynamic Exoskeletal Orthosis was created. To date, this device has significantly improved the functional capabilities of the limb salvage wounded warrior population when combined with a high-intensity rehabilitation program. Clinical and biomechanical research is currently underway at this institution in order to fully characterize the device, its effect on patients, and what can be done to modify future generations of the device to best serve the combat-wounded limb salvage population.
Brogioli, Michael; Popp, Werner L; Albisser, Urs; Brust, Anne K; Frotzler, Angela; Gassert, Roger; Curt, Armin; Starkey, Michelle L
2016-11-01
After spinal cord injury (SCI), levels of independence are commonly assessed with standardized clinical assessments. However, such tests do not provide information about the actual extent of upper limb activities or the impact on independence of bi- versus unilateral usage throughout daily life following cervical SCI. The objective of this study was to correlate activity intensity and laterality of upper extremity activity measured by body-fixed inertial measurement units (IMUs) with clinical assessment scores of independence. Limb-use intensity and laterality of activities performed by the upper extremities was measured in 12 subjects with cervical SCI using four IMUs (positioned on both wrists, on the chest, and on one wheel of the wheelchair). Algorithms capable of reliably detecting self-propulsion and arm activity in a clinical environment were applied to rate functional outcome levels, and were related to clinical independence measures during inpatient rehabilitation. Measures of intensity of upper extremity activity during self-propulsion positively correlated (p < 0.05, r = 0.643) with independence measures related to mobility. Clinical measures of laterality were positively correlated (p < 0.01, r = 0.900) with laterality as measured by IMUs during "daily life," and increased laterality was negatively correlated (p < 0.01, r = -0.739) with independence. IMU sensor technology is sensitive in assessing and quantifying upper limb-use intensity and laterality in human cervical SCI. Continuous and objective movement data of distinct daily activities (i.e., mobility and day-to-day activities) can be related to levels of independence. Therefore, IMU sensor technology is suitable not only for monitoring activity levels during rehabilitation (including during clinical trials) but could also be used to assess levels of participation after discharge.
Vertical Distribution of Aerosols and Water Vapor Using CRISM Limb Observations
NASA Astrophysics Data System (ADS)
Smith, M. D.; Wolff, M. J.; Clancy, R. T.; CRISM Science; Operations Teams
2011-12-01
Near-infrared spectra taken in a limb-viewing geometry by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) on-board the Mars Reconnaissance Orbiter (MRO) provide a useful tool for probing atmospheric structure. Specifically, the observed radiance as a function of wavelength and height above the limb allows the vertical distribution of both dust and ice aerosols to be retrieved. These data serve as an important supplement to the aerosol profiling provided by the MRO/MCS instrument allowing independent validation and giving additional information on particle physical and scattering properties through multi-wavelength studies. A total of at least ten CRISM limb observations have been taken so far covering a full Martian year. Each set of limb observations nominally contains about four dozen scans across the limb giving pole-to-pole coverage for two orbits at roughly 100 and 290 W longitude over the Tharsis and Syrtis/Hellas regions, respectively. At each longitude, limb scans are spaced roughly 10 degrees apart in latitude, with a vertical spatial resolution on the limb of roughly 800 m. Radiative transfer modeling is used to model the observations. We compute synthetic CRISM limb spectra using a discrete-ordinates radiative transfer code that accounts for multiple scattering from aerosols and accounts for spherical geometry of the limb observations by integrating the source functions along curved paths in that coordinate system. Retrieved are 14-point vertical profiles for dust and water ice aerosols with resolution of 0.4 scale heights between one and six scale heights above the surface. After the aerosol retrieval is completed, the abundances of CO2 (or surface pressure) and H2O gas are retrieved by matching the depth of absorption bands at 2000 nm for carbon dioxide and at 2600 nm for water vapor. In addition to the column abundance of water vapor, limited information on its vertical structure can also be retrieved depending on the signal available from aerosol scattering. Significant differences are seen in the retrieved vertical profiles of dust and water ice as a function of season. Dust typically extends to higher altitudes during the perihelion season. Ice aerosols are often observed to cap the dust layer during all seasons. Water vapor is observed to be deeply mixed in the perihelion season and confined near the surface in the aphelion season. The CRISM limb-geometry observations support the quantitative retrieval of aerosol and gas vertical profiles. These quantities cannot be retrieved using nadir observations, and they enable the study of important new science questions. The CRISM limbs also serve as a valuable supplement to the MRO/MCS limb profiles, enabling validation and multi-wavelength comparisons. Additional CRISM limb-geometry sets will continue to be taken approximately every two months (~30 degrees of Ls) as operations allow.
2014-01-01
Background Mechanical loads induced through muscle contraction, vibration, or compressive forces are thought to modulate tissue plasticity. With the emergence of regenerative medicine, there is a need to understand the optimal mechanical environment (vibration, load, or muscle force) that promotes cellular health. To our knowledge no mechanical system has been proposed to deliver these isolated mechanical stimuli in human tissue. We present the design, performance, and utilization of a new technology that may be used to study localized mechanical stimuli on human tissues. A servo-controlled vibration and limb loading system were developed and integrated into a single instrument to deliver vibration, compression, or muscle contractile loads to a single limb (tibia) in humans. The accuracy, repeatability, transmissibility, and safety of the mechanical delivery system were evaluated on eight individuals with spinal cord injury (SCI). Findings The limb loading system was linear, repeatable, and accurate to less than 5, 1, and 1 percent of full scale, respectively, and transmissibility was excellent. The between session tests on individuals with spinal cord injury (SCI) showed high intra-class correlations (>0.9). Conclusions All tests supported that therapeutic loads can be delivered to a lower limb (tibia) in a safe, accurate, and measureable manner. Future collaborations between engineers and cellular physiologists will be important as research programs strive to determine the optimal mechanical environment for developing cells and tissues in humans. PMID:24894666
49 CFR 572.154 - Thorax assembly and test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... R5 of this subpart, with the lower limbs extended forward, parallel to the midsagittal plane and the arms 0 to 5 degrees forward of vertical. The dummy's midsagittal plane is vertical within ±/1 degree... alignment). (4) Establish the impact point at the chest midsagittal plane so that the impact point of the...
Mahadevan, Devendra; Lines, Stephen; Hepple, Stephen; Winson, Ian; Harries, William
2016-06-01
The purpose of this RCT was to compare the extended plantar limb (modified) chevron osteotomy with the scarf osteotomy in correcting hallux valgus deformity and improving functional scores and patient satisfaction. Patients were randomly assigned and kept blind to surgical allocation. Cases requiring additional procedures including the Akin osteotomy were excluded. Outcomes were measured at 1 year following surgery. 84 patients (109 feet) were analysed (60 modified chevron; 49 Scarf). The mean age was 50.7 years (75F: 9M). Post-operative intermetatarsal angle (IMA) was significantly lower in the modified chevron group (5.8° versus 6.9°, p=0.045). Hallux valgus angle and distal metatarsal articular angle were similar. The magnitude of IMA correction with the modified chevron was also significantly greater (9.1° versus 7.1°, p=0.007). Both osteotomies produced comparable MOxFQ scores and satisfaction ratings. The modified chevron was superior to the scarf osteotomy in correcting IMA in hallux valgus deformity. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
PROTOTYPE SCALE TESTING OF LIMB TECHNOLOGY FOR A PULVERIZED-COAL-FIRED BOILER
The report summarizes results of an evaluation of furnace sorbent injection (FSI) to control sulfur dioxide (SO2) emissions from coal-fired utility boilers. (NOTE: FSI of calcium-based sorbents has shown promise as a moderate SO2 removal technology.) The Electric Power Research I...
ERIC Educational Resources Information Center
Presperin, Jessica J., Ed.
This proceedings document contains approximately 250 papers and posters presented at a conference on the advancement of rehabilitation and assistive technology. Individual sessions focused on the following topics: quantitative functional evaluation, upper limb and therapeutic stimulation, human-computer interface developments, information…
Petrucci, Emiliano; Pizzi, Barbara; Scimia, Paolo; Conti, Giuseppe; Di Carlo, Stefano; Santini, Antonella; Fusco, Pierfrancesco
2018-06-01
Trauma care in cave rescue is a unique situation that requires an advanced and organized approach with medical and technical assistance because of the extreme environmental conditions and logistical factors. In caving accidents, the most common injuries involve lower limbs. We describe an advanced medical rescue performed by the Italian Corpo Nazionale del Soccorso Alpino e Speleologico, in which extended focused assessment with sonography for trauma and an ultrasound-guided adductor canal block were performed on a patient with a knee distortion directly in the cave. The rescue team inside the cave shared data on patient monitoring and the ultrasound scanning in real time with rescuers at the entrance, using a video conference powered by the new Ermes system. The use of handheld, battery-powered, low-weight, multiparametric monitors, ultrasound machines, and digital data transmission systems could ensure complete medical assistance in harsh environmental conditions such as those found in a cave. Copyright © 2018 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
Tsekleves, Emmanuel; Paraskevopoulos, Ioannis Theoklitos; Warland, Alyson; Kilbride, Cherry
2016-01-01
This paper proposes a novel system (using the Nintendo Wii remote) that offers customised, non-immersive, virtual reality-based, upper-limb stroke rehabilitation and reports on promising preliminary findings with stroke survivors. The system novelty lies in the high accuracy of the full kinematic tracking of the upper limb movement in real-time, offering strong personal connection between the stroke survivor and a virtual character when executing therapist prescribed adjustable exercises/games. It allows the therapist to monitor patient performance and to individually calibrate the system in terms of range of movement, speed and duration. The system was tested for acceptability with three stroke survivors with differing levels of disability. Participants reported an overwhelming connection with the system and avatar. A two-week, single case study with a long-term stroke survivor showed positive changes in all four outcome measures employed, with the participant reporting better wrist control and greater functional use. Activities, which were deemed too challenging or too easy were associated with lower scores of enjoyment/motivation, highlighting the need for activities to be individually calibrated. Given the preliminary findings, it would be beneficial to extend the case study in terms of duration and participants and to conduct an acceptability and feasibility study with community dwelling survivors. Implications for Rehabilitation Low-cost, off-the-shelf game sensors, such as the Nintendo Wii remote, are acceptable by stroke survivors as an add-on to upper limb stroke rehabilitation but have to be bespoked to provide high-fidelity and real-time kinematic tracking of the arm movement. Providing therapists with real-time and remote monitoring of the quality of the movement and not just the amount of practice, is imperative and most critical for getting a better understanding of each patient and administering the right amount and type of exercise. The ability to translate therapeutic arm movement into individually calibrated exercises and games, allows accommodation of the wide range of movement difficulties seen after stroke and the ability to adjust these activities (in terms of speed, range of movement and duration) will aid motivation and adherence - key issues in rehabilitation. With increasing pressures on resources and the move to more community-based rehabilitation, the proposed system has the potential for promoting the intensity of practice necessary for recovery in both community and acute settings.
The computer-aided parallel external fixator for complex lower limb deformity correction.
Wei, Mengting; Chen, Jianwen; Guo, Yue; Sun, Hao
2017-12-01
Since parameters of the parallel external fixator are difficult to measure and calculate in real applications, this study developed computer software that can help the doctor measure parameters using digital technology and generate an electronic prescription for deformity correction. According to Paley's deformity measurement method, we provided digital measurement techniques. In addition, we proposed an deformity correction algorithm to calculate the elongations of the six struts and developed a electronic prescription software. At the same time, a three-dimensional simulation of the parallel external fixator and deformed fragment was made using virtual reality modeling language technology. From 2013 to 2015, fifteen patients with complex lower limb deformity were treated with parallel external fixators and the self-developed computer software. All of the cases had unilateral limb deformity. The deformities were caused by old osteomyelitis in nine cases and traumatic sequelae in six cases. A doctor measured the related angulation, displacement and rotation on postoperative radiographs using the digital measurement techniques. Measurement data were input into the electronic prescription software to calculate the daily adjustment elongations of the struts. Daily strut adjustments were conducted according to the data calculated. The frame was removed when expected results were achieved. Patients lived independently during the adjustment. The mean follow-up was 15 months (range 10-22 months). The duration of frame fixation from the time of application to the time of removal averaged 8.4 months (range 2.5-13.1 months). All patients were satisfied with the corrected limb alignment. No cases of wound infections or complications occurred. Using the computer-aided parallel external fixator for the correction of lower limb deformities can achieve satisfactory outcomes. The correction process can be simplified and is precise and digitized, which will greatly improve the treatment in a clinical application.
Tanabe, Shigeo; Koyama, Soichiro; Saitoh, Eiichi; Hirano, Satoshi; Yatsuya, Kanan; Tsunoda, Tetsuya; Katoh, Masaki; Gotoh, Takeshi; Furumoto, Ayako
2017-01-01
Patients with tetraplegia can achieve independent gait with lateral-type powered exoskeletons; it is unclear whether medial-type powered exoskeletons allow for this. To investigate gait training with a medial-type powered exoskeleton wearable power-assist locomotor (WPAL) in an individual with incomplete cervical (C5) and complete thoracic (T12) spinal cord injury (SCI). The 60-session program was investigated retrospectively using medical records. Upon completion, gait performance was examined using three-dimensional motion analyses and surface electromyography (EMG) of the upper limbs. The subject achieved independent gait with WPAL and a walker in 12 sessions. He continuously extended his right elbow; his left elbow periodically flexed/extended. His pelvic inclination was larger than the trunk inclination during single-leg stance. EMG activity was increased in the left deltoid muscles during ipsilateral foot-contact. The right anterior and medial deltoid muscle EMG activity increased just after foot-off for each leg, as did the right biceps activity. Continuous activity was observed in the left triceps throughout the gait cycle; activity was unclear in the right triceps. These results suggest the importance of upper limb residual motor function, and may be useful in extending the range of clinical applications for robotic gait rehabilitation in patients with SCI.
2016-01-14
This processed image is the highest-resolution color look yet at the haze layers in Pluto's atmosphere. Shown in approximate true color, the picture was constructed from a mosaic of four panchromatic images from the Long Range Reconnaissance Imager (LORRI) splashed with Ralph/Multispectral Visible Imaging Camera (MVIC) four-color filter data, all acquired by NASA's New Horizons spacecraft on July 14, 2015. The resolution is 1 kilometer (0.6 miles) per pixel; the sun illuminates the scene from the right. Scientists believe the haze is a photochemical smog resulting from the action of sunlight on methane and other molecules in Pluto's atmosphere, producing a complex mixture of hydrocarbons such as acetylene and ethylene. These hydrocarbons accumulate into small particles, a fraction of a micrometer in size, and scatter sunlight to make the bright blue haze seen in this image. As they settle down through the atmosphere, the haze particles form numerous intricate, horizontal layers, some extending for hundreds of miles around Pluto. The haze layers extend to altitudes of over 200 kilometers (120 miles). Adding to the stark beauty of this image are mountains on Pluto's limb (on the right, near the 4 o'clock position), surface features just within the limb to the right, and crepuscular rays (dark finger-like shadows to the left) extending from Pluto's topographic features. http://photojournal.jpl.nasa.gov/catalog/PIA20362
Vertical Distribution of Dust and Water Ice Aerosols from CRISM Limb-geometry Observations
NASA Technical Reports Server (NTRS)
Smith, Michael Doyle; Wolff, Michael J.; Clancy, Todd; Kleinbohl, Armin; Murchie, Scott L.
2013-01-01
[1] Near-infrared spectra taken in a limb-viewing geometry by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) on board the Mars Reconnaissance Orbiter provide a useful tool for probing atmospheric structure. Specifically, the observed radiance as a function of wavelength and height above the limb enables the vertical distribution of both dust and water ice aerosols to be retrieved. More than a dozen sets of CRISM limb observations have been taken so far providing pole-to-pole cross sections, spanning more than a full Martian year. Radiative transfer modeling is used to model the observations taking into account multiple scattering from aerosols and the spherical geometry of the limb observations. Both dust and water ice vertical profiles often show a significant vertical structure for nearly all seasons and latitudes that is not consistent with the well-mixed or Conrath-v assumptions that have often been used in the past for describing aerosol vertical profiles for retrieval and modeling purposes. Significant variations are seen in the retrieved vertical profiles of dust and water ice aerosol as a function of season. Dust typically extends to higher altitudes (approx. 40-50km) during the perihelion season than during the aphelion season (<20km), and the Hellas region consistently shows more dust mixed to higher altitudes than other locations. Detached water ice clouds are common, and water ice aerosols are observed to cap the dust layer in all seasons.
Kingston, David C; Riddell, Maureen F; McKinnon, Colin D; Gallagher, Kaitlin M; Callaghan, Jack P
2016-02-01
We evaluated the effect of work surface angle and input hardware on upper-limb posture when using a hybrid computer workstation. Offices use sit-stand and/or tablet workstations to increase worker mobility. These workstations may have negative effects on upper-limb joints by increasing time spent in non-neutral postures, but a hybrid standing workstation may improve working postures. Fourteen participants completed office tasks in four workstation configurations: a horizontal or sloped 15° working surface with computer or tablet hardware. Three-dimensional right upper-limb postures were recorded during three tasks: reading, form filling, and writing e-mails. Amplitude probability distribution functions determined the median and range of upper-limb postures. The sloped-surface tablet workstation decreased wrist ulnar deviation by 5° when compared to the horizontal-surface computer when reading. When using computer input devices (keyboard and mouse), the shoulder, elbow, and wrist were closest to neutral joint postures when working on a horizontal work surface. The elbow was 23° and 15° more extended, whereas the wrist was 6° less ulnar deviated, when reading compared to typing forms or e-mails. We recommend that the horizontal-surface computer configuration be used for typing and the sloped-surface tablet configuration be used for intermittent reading tasks in this hybrid workstation. Offices with mobile employees could use this workstation for alternating their upper-extremity postures; however, other aspects of the device need further investigation. © 2015, Human Factors and Ergonomics Society.
Fadeeva, Natalia; Mordukhovich, Vladimir; Zograf, Julia
2016-05-02
Four new Campylaimus species are described from the deep-sea sediments of the Sea of Japan at depths of about 500‒3400 m. Campylaimus orientalis sp. nov. is characterized by having a body of moderate length, clearly annulated cuticle, a small rhomboid mouth opening which is displaced on the dorsal side of body, a gap between the unequal limbs of the amphid, prominent narrow longitudinal alae and cephalated spicules. Campylaimus minutus sp. nov. is characterized by having a cylindrical body, very weak annulations, amphids with a short dorsal limb (25-44% of pharynx length) and a ventral limb completely fused with lateral alae of equal width; and lateral alae extending from the base of the amphid to the tail tip. Campylaimus amphidialis sp. nov. is characterized by having the combination of a very long amphidial fovea occupying nearly the entire length of the pharynx; and a well defined boundary between the ventral amphid limb and lateral alae. The distinctive feature of Campylaimus pulcher sp. nov. is the elongated loop-shaped amphid with nearly equal parallel limbs and prominent narrow longitudinal alae; and cephalated spicules without a gubernaculum. The diagnosis of the genus Campylaimus is emended and an identification key to species, based mainly on form and length of amphidial fovea, width of lateral alae, and copulatory apparatus is given. The genus Campylaimus now includes nineteen valid species. Two species are considered as species inquirendae, mainly because of incomplete descriptions.
Serious games for upper limb rehabilitation: a systematic review.
Proença, João Pedro; Quaresma, Cláudia; Vieira, Pedro
2018-01-01
The aim of this research is to carry out a systematic review of the use of technological gaming platforms with serious games in the upper limb rehabilitation of patients with neuromotor disorders. Through a systematic review, the first two authors defined the inclusion criteria and extracted the data, resulting in 38 studies collected from B-On, PubMed and Medline. Ninety-two per cent of the selected articles were published since 2010. This review documents 35 different gaming platforms types. Twenty-one of the 38 articles included in this review conducted a clinical trial and of those only eight report improvements in the target population following the use of the games and platforms. This review concludes that a new paradigm is emerging in the rehabilitation field, characterized by the systematic use of technological gaming platforms with serious games in/for rehabilitation. The use of this approach seems to be beneficial. However, to facilitate the full integration of these platforms, it is necessary to conduct more research in this area, explore new approaches and carry out in-depth clinical studies into the benefits of these platforms. Implications for rehabilitation This review states that the use serious games and gaming platforms for upper limb rehabilitation are starting a new paradigm in the rehabilitation. For a full integration of this technologies in the rehabilitation field more studies are needed.
FGFR3 is a target of the homeobox transcription factor SHOX in limb development.
Decker, Eva; Durand, Claudia; Bender, Sebastian; Rödelsperger, Christian; Glaser, Anne; Hecht, Jochen; Schneider, Katja U; Rappold, Gudrun
2011-04-15
The short stature homeobox gene SHOX encodes a transcription factor which is important for normal limb development. In humans, SHOX deficiency has been associated with various short stature syndromes including Leri-Weill dyschondrosteosis (LWD), Langer mesomelic dysplasia and Turner syndrome as well as non-syndromic idiopathic short stature. A common feature of these syndromes is disproportionate short stature with a particular shortening of the forearms and lower legs. In our studies employing microarray analyses and cell culture experiments, we revealed a strong positive effect of SHOX on the expression of the fibroblast growth factor receptor gene FGFR3, another well-known factor for limb development. Luciferase reporter gene assays show that SHOX activates the extended FGFR3 promoter, and results from chromatin immunoprecipitation (ChIP)-sequencing, ChIP and electrophoretic mobility shift assay experiments suggest a direct binding of SHOX to multiple upstream sequences of FGFR3. To further investigate these regulations in a cellular system for limb development, the effect of viral overexpression of Shox in limb bud derived chicken micromass cultures was tested. We found that Fgfr3 was negatively regulated by Shox, as demonstrated by quantitative real-time polymerase chain reaction and in situ hybridization. This repressive effect might explain the almost mutually exclusive expression patterns of Fgfr3 and Shox in embryonic chicken limbs. A negative regulation that occurs mainly in the mesomelic segments, a region where SHOX is known to be strongly expressed, offers a possible explanation for the phenotypes seen in patients with FGFR3 (e.g. achondroplasia) and SHOX defects (e.g. LWD). In summary, these data present a link between two frequent short stature phenotypes.
Chau, Brian; Phelan, Ivan; Ta, Phillip; Humbert, Sarah; Hata, Justin; Tran, Duc
2017-01-01
Objective: Phantom limb pain is a condition frequently experienced after amputation. One treatment for phantom limb pain is traditional mirror therapy, yet some patients do not respond to this intervention, and immersive virtual reality mirror therapy offers some potential advantages. We report the case of a patient with severe phantom limb pain following an upper limb amputation and successful treatment with therapy in a custom virtual reality environment. Methods: An interactive 3-D kitchen environment was developed based on the principles of mirror therapy to allow for control of virtual hands while wearing a motion-tracked, head-mounted virtual reality display. The patient used myoelectric control of a virtual hand as well as motion-tracking control in this setting for five therapy sessions. Pain scale measurements and subjective feedback was elicited at each session. Results: Analysis of the measured pain scales showed statistically significant decreases per session [Visual Analog Scale, Short Form McGill Pain Questionnaire, and Wong-Baker FACES pain scores decreased by 55 percent (p=0.0143), 60 percent (p=0.023), and 90 percent (p=0.0024), respectively]. Significant subjective pain relief persisting between sessions was also reported, as well as marked immersion within the virtual environments. On followup at six weeks, the patient noted continued decrease in phantom limb pain symptoms. Conclusions: Currently available immersive virtual reality technology with myolectric and motion tracking control may represent a possible therapy option for treatment-resistant phantom limb pain.
Phelan, Ivan; Ta, Phillip; Humbert, Sarah; Hata, Justin; Tran, Duc
2017-01-01
Objective: Phantom limb pain is a condition frequently experienced after amputation. One treatment for phantom limb pain is traditional mirror therapy, yet some patients do not respond to this intervention, and immersive virtual reality mirror therapy offers some potential advantages. We report the case of a patient with severe phantom limb pain following an upper limb amputation and successful treatment with therapy in a custom virtual reality environment. Methods: An interactive 3-D kitchen environment was developed based on the principles of mirror therapy to allow for control of virtual hands while wearing a motion-tracked, head-mounted virtual reality display. The patient used myoelectric control of a virtual hand as well as motion-tracking control in this setting for five therapy sessions. Pain scale measurements and subjective feedback was elicited at each session. Results: Analysis of the measured pain scales showed statistically significant decreases per session [Visual Analog Scale, Short Form McGill Pain Questionnaire, and Wong-Baker FACES pain scores decreased by 55 percent (p=0.0143), 60 percent (p=0.023), and 90 percent (p=0.0024), respectively]. Significant subjective pain relief persisting between sessions was also reported, as well as marked immersion within the virtual environments. On followup at six weeks, the patient noted continued decrease in phantom limb pain symptoms. Conclusions: Currently available immersive virtual reality technology with myolectric and motion tracking control may represent a possible therapy option for treatment-resistant phantom limb pain. PMID:29616149
The benefit of limb cloud imaging for infrared limb sounding of tropospheric trace gases
NASA Astrophysics Data System (ADS)
Adams, S.; Spang, R.; Preusse, P.; Heinemann, G.
2009-06-01
Advances in detector technology enable a new generation of infrared limb sounders to measure 2-D images of the atmosphere. A proposed limb cloud imager (LCI) mode will detect clouds with a spatial resolution unprecedented for limb sounding. For the inference of temperature and trace gas distributions, detector pixels of the LCI have to be combined into super-pixels which provide the required signal-to-noise and information content for the retrievals. This study examines the extent to which tropospheric coverage can be improved in comparison to limb sounding using a fixed field of view with the size of the super-pixels, as in conventional limb sounders. The study is based on cloud topographies derived from (a) IR brightness temperatures (BT) of geostationary weather satellites in conjunction with ECMWF temperature profiles and (b) ice and liquid water content data of the Consortium for Small-scale Modeling-Europe (COSMO-EU) of the German Weather Service. Limb cloud images are simulated by matching the cloud topography with the limb sounding line of sight (LOS). The analysis of the BT data shows that the reduction of the spatial sampling along the track has hardly any effect on the gain in information. The comparison between BT and COSMO-EU data identifies the strength of both data sets, which are the representation of the horizontal cloud extent for the BT data and the reproduction of the cloud amount for the COSMO-EU data. The results of the analysis of both data sets show the great advantage of the cloud imager. However, because both cloud data sets do not present the complete fine structure of the real cloud fields in the atmosphere it is assumed that the results tend to underestimate the increase in information. In conclusion, real measurements by such an instrument may result in an even higher benefit for tropospheric limb retrievals.
Lipoate ameliorates ischemia-reperfusion in animal models.
Freisleben, H J
2000-01-01
Ischemia and reperfusion were studied in isolated working rat hearts and in exarticulated rat hind limbs. Free radicals are known to be generated in ischemia/reperfusion and to propagate complications. To reduce reperfusion injury, conditions were ameliorated including the treatment with antioxidants, lipoate or dihydrolipoate. In isolated working rat hearts, cardiac and mitochondrial parameters are impaired during hypoxia and partially recover in reperfusion. Dihydrolipoate, if added into the perfusion buffer at 0.3 microM concentration, keeps the pH higher (7.15) during hypoxia, as compared to controls (6.98). This compound accelerates and stabilizes the recovery of the aortic flow. With dihydrolipoate, ATP synthesis is increased, ATPase activity (ATP hydrolysis) reduced, intracellular creatine kinase activity maintained and thus phosphocreatine contents are higher than in controls. For exarticulated rat hind limbs, the dihydrolipoate group contained 8.3 microM in the modified reperfusate. Recovery of the contractile function was 49% vs. 34% in controls and muscle flexibility was maintained whereas it decreased by 15% in the controls. Release of creatine kinase from cells was significantly lower with dihydrolipoate. Lipoate/dihydrolipoate effectively reduced reperfusion injury in isolated working rat hearts and in exarticulated rat hind limbs after extended ischemia. Finally, the compound was successfully applied in an in vivo pig hind limb model.
Cortés, Camilo; de los Reyes-Guzmán, Ana; Scorza, Davide; Bertelsen, Álvaro; Carrasco, Eduardo; Gil-Agudo, Ángel; Ruiz-Salguero, Oscar; Flórez, Julián
2016-01-01
Robot-Assisted Rehabilitation (RAR) is relevant for treating patients affected by nervous system injuries (e.g., stroke and spinal cord injury). The accurate estimation of the joint angles of the patient limbs in RAR is critical to assess the patient improvement. The economical prevalent method to estimate the patient posture in Exoskeleton-based RAR is to approximate the limb joint angles with the ones of the Exoskeleton. This approximation is rough since their kinematic structures differ. Motion capture systems (MOCAPs) can improve the estimations, at the expenses of a considerable overload of the therapy setup. Alternatively, the Extended Inverse Kinematics Posture Estimation (EIKPE) computational method models the limb and Exoskeleton as differing parallel kinematic chains. EIKPE has been tested with single DOF movements of the wrist and elbow joints. This paper presents the assessment of EIKPE with elbow-shoulder compound movements (i.e., object prehension). Ground-truth for estimation assessment is obtained from an optical MOCAP (not intended for the treatment stage). The assessment shows EIKPE rendering a good numerical approximation of the actual posture during the compound movement execution, especially for the shoulder joint angles. This work opens the horizon for clinical studies with patient groups, Exoskeleton models, and movements types. PMID:27403420
Non-LTE diagnositics of infrared radiation of Titan's atmosphere
NASA Astrophysics Data System (ADS)
Feofilov, Artem; Rezac, Ladislav; Kutepov, Alexander; Vinatier, Sandrine; Rey, Michael; Nikitin, Andrew; Tyuterev, Vladimir
2016-06-01
Yelle (1991) and Garcia-Comas et al, (2011) demonstrated the importance of accounting for the local thermodynamic equilibrium (LTE) breakdown in the middle and upper atmosphere of Titan for the interpretation of infrared radiances measured at these heights. In this work, we make further advance in this field by: • updating the non-LTE model of CH4 emissions in Titan's atmosphere and including a new extended database of CH4 spectroscopic parameters • studying the non-LTE CH4 vibrational level populations and the impact of non-LTE on limb infrared emissions of various CH4 ro-vibrational bands including those at 7.6 and 3.3 µm • implementing our non-LTE model into the LTE-based retrieval algorithm applied by Vinatier et al., (2015) for processing the Cassini/CIRS spectra. We demonstrate that accounting for non-LTE leads to an increase in temperatures retrieved from CIRS 7.6 µm limb emissions spectra (˜10 K at 600 km altitude) and estimate how this affects the trace gas density retrieval. Finally, we discuss the effects of including a large number of weak one-quantum and combinational bands on the calculated daytime limb 3.3 µm emissions and the impact they may have on the CH4 density retrievals from the Cassini VIMS 3.3 µm limb emission observations.
Case Studies of the Mesospheric Response to Recent Minor, Major, and Extended Stratospheric Warmings
2010-06-06
Pawson, J. N. Lee , W. H. Daffer, R. A. Fuller, and N. J. Livesey (2009b), Aura Micro- wave Limb Sounder observations of dynamics and transport during...Schoeberl, M., D. Strobel , and J. Apruzese (1983), A numerical model of gravity wave breaking and stress in the mesosphere, J. Geophys. Res., 88(C9
Total Solar Eclipse of 2008 August 01
NASA Technical Reports Server (NTRS)
Espenak, F.; Anderson, J.
2007-01-01
On 2008 August 01, a total eclipse of the Sun is visible from within a narrow corridor that traverses half the Earth. The path of the Moon's umbral shadow begins in northern Canada and extends across Greenland, the Arctic, central Russia, Mongolia, and China. A partial eclipse is seen within the much broader path of the Moon's penumbral shadow, which includes northeastern North America, most of Europe and Asia. Detailed predictions for this event are presented and include besselian elements, geographic coordinates of the path of totality, physical ephemeris of the umbra, topocentric limb profile corrections, local circumstances for 308 cities, maps of the eclipse path, weather prospects, the lunar limb profile and the sky during totality. Information on safe eclipse viewing and eclipse photography is included.
Ethical considerations in providing an upper limb exoskeleton device for stroke patients.
Bulboacă, Adriana E; Bolboacă, Sorana D; Bulboacă, Angelo C
2017-04-01
The health care system needs to face new and advanced medical technologies that can improve the patients' quality of life by replacing lost or decreased functions. In stroke patients, the disabilities that follow cerebral lesions may impair the mandatory daily activities of an independent life. These activities are dependent mostly on the patient's upper limb function so that they can carry out most of the common activities associated with a normal life. Therefore, an upper limb exoskeleton device for stroke patients can contribute a real improvement of quality of their life. The ethical problems that need to be considered are linked to the correct adjustment of the upper limb skills in order to satisfy the patient's expectations, but within physiological limits. The debate regarding the medical devices dedicated to neurorehabilitation is focused on their ability to be beneficial to the patient's life, keeping away damages, injustice, and risks. Copyright © 2017 Elsevier Ltd. All rights reserved.
Biofeedback for Gait Retraining Based on Real-Time Estimation of Tibiofemoral Joint Contact Forces.
Pizzolato, Claudio; Reggiani, Monica; Saxby, David J; Ceseracciu, Elena; Modenese, Luca; Lloyd, David G
2017-09-01
Biofeedback assisted rehabilitation and intervention technologies have the potential to modify clinically relevant biomechanics. Gait retraining has been used to reduce the knee adduction moment, a surrogate of medial tibiofemoral joint loading often used in knee osteoarthritis research. In this paper, we present an electromyogram-driven neuromusculoskeletal model of the lower-limb to estimate, in real-time, the tibiofemoral joint loads. The model included 34 musculotendon units spanning the hip, knee, and ankle joints. Full-body inverse kinematics, inverse dynamics, and musculotendon kinematics were solved in real-time from motion capture and force plate data to estimate the knee medial tibiofemoral contact force (MTFF). We analyzed five healthy subjects while they were walking on an instrumented treadmill with visual biofeedback of their MTFF. Each subject was asked to modify their gait in order to vary the magnitude of their MTFF. All subjects were able to increase their MTFF, whereas only three subjects could decrease it, and only after receiving verbal suggestions about possible gait modification strategies. Results indicate the important role of knee muscle activation patterns in modulating the MTFF. While this paper focused on the knee, the technology can be extended to examine the musculoskeletal tissue loads at different sites of the human body.
NASA Technical Reports Server (NTRS)
Edgerton, V. R.; Roy, R. R.; Hodgson, J. A.; Day, M. K.; Weiss, J.; Harkema, S. J.; Dobkin, B.; Garfinkel, A.; Konigsberg, E.; Koslovskaya, I.
2000-01-01
Space programs support experimental investigations related to the unique environment of space and to the technological developments from many disciplines of both science and engineering that contribute to space studies. Furthermore, interactions between scientists, engineers and administrators, that are necessary for the success of any science mission in space, promote interdiscipline communication, understanding and interests which extend well beyond a specific mission. NASA-catalyzed collaborations have benefited the spinal cord rehabilitation program at UCLA in fundamental science and in the application of expertise and technologies originally developed for the space program. Examples of these benefits include: (1) better understanding of the role of load in maintaining healthy muscle and motor function, resulting in a spinal cord injury (SCI) rehabilitation program based on muscle/limb loading; (2) investigation of a potentially novel growth factor affected by spaceflight which may help regulate muscle mass; (3) development of implantable sensors, electronics and software to monitor and analyze long-term muscle activity in unrestrained subjects; (4) development of hardware to assist therapies applied to SCI patients; and (5) development of computer models to simulate stepping which will be used to investigate the effects of neurological deficits (muscle weakness or inappropriate activation) and to evaluate therapies to correct these deficiencies.
Shih, Ching-Hsiang; Wang, Shu-Hui; Wang, Yun-Ting
2014-09-01
Recent studies in the field of special education have shown that in combination with software technology, high-tech commercial products can be applied as useful assistive technology devices to help people with disabilities. This study extended this concept to turn a Nintendo Wii Remote Controller into a high-performance limb action detector, in order to evaluate whether two students with Attention Deficit Hyperactivity Disorder (ADHD) could reduce their hyperactive behavior through an active reminder and stimulation in the form of the participants' preferred rewards. This study focused on one particular hyperactive behavior common to both students: standing up arbitrarily during class. The active reminder was in the form of vibration feedback provided via the built-in function of the Wii Remote Controller, which was controlled and triggered by a control system to remind participants when they were engaging in standing behavior. This study was performed according to a multiple baseline design across participants. The results showed that both participants significantly improved their control over their hyperactive behavior during the intervention phase, and retained this effective performance in the maintenance phase. The practical and developmental implications of the findings are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ajello, J. M.; West, R. A.; Malone, C. P.; Gustin, J.; Esposito, L. W.; McClintock, W. E.; Holsclaw, G. M.; Stevens, M. H.
2011-12-01
Joseph M. Ajello, Robert A. West, Rao S. Mangina Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 Charles P. Malone Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 & Department of Physics, California State University, Fullerton, CA 92834 Michael H. Stevens Space Science Division, Naval Research Laboratory, Washington, DC 20375 Jacques Gustin Laboratoire de Physique Atmosphérique et Planétaire, Université de Liège, Liège, Belgium A. Ian F. Stewart, Larry W. Esposito, William E. McClintock, Gregory M. Holsclaw Laboratory for Atmospheric and Space Physics, University of Colorado, Boulder, CO 80303 E. Todd Bradley Department of Physics, University of Central Florida, Orlando, FL 32816 The Cassini Ultraviolet Imaging Spectrograph (UVIS) observed photon emissions of Titan's day and night limb-airglow and disk-airglow on multiple occasions, including three eclipse observations from 2009 through 2010. The 77 airglow observations analyzed in this paper show EUV (600-1150 Å) and FUV (1150-1900 Å) atomic multiplet lines and band emissions (lifetimes less than ~100 μs), including the Lyman-Birge-Hopfield (LBH) band system, arising from photoelectron induced fluorescence and solar photo-fragmentation of molecular nitrogen (N2). The altitude of peak UV emission on the limb of Titan during daylight occurred inside the thermosphere/ionosphere (near 1000 km altitude). However, at night on the limb, the same emission features, but much weaker in intensity, arise in the lower atmosphere below 1000 km (lower thermosphere, mesosphere, haze layer) extending downwards to near the surface at ~300 km, possibly resulting from proton- and/or heavier ion-induced emissions as well as secondary-electron-induced emissions. The eclipse observations are unique. UV emissions were observed during only one of the three eclipse events, and no Vegard-Kaplan (VK) or LBH emissions were seen. Through regression analysis using laboratory spectra, we have analyzed the intensity and identified each spectral feature from the limb or disk emission spectrum. The strongest dipole-allowed transitions of N2 occur in the EUV. The electronic transitions proceed from the X 1Σg+ ground-state to about seven closely spaced (~12-15 eV) Rydberg-valence (RV) states, which are the source of the molecular emissions in the EUV observed by spacecraft and have recently been studied in our laboratory at medium-to-high spectral resolution (delta-λ = 0.1 Å FWHM). Three of these RV states (b 1Πu, b' 1Σu+, and c4' 1Σu+) are highly-perturbed, weakly-to-strongly predissociated, and have significant emission cross sections, which will be summarized in this paper. We will also discuss our recently published proton and electron impact emission cross sections for the LBH (a 1Πg - X 1Σg+) band system of N2, and their significance to the modeling of the day and night FUV spectra of the atmospheres of Earth and Titan.
Ma, Xuan; Ma, Chaolin; Huang, Jian; Zhang, Peng; Xu, Jiang; He, Jiping
2017-01-01
Extensive literatures have shown approaches for decoding upper limb kinematics or muscle activity using multichannel cortical spike recordings toward brain machine interface (BMI) applications. However, similar topics regarding lower limb remain relatively scarce. We previously reported a system for training monkeys to perform visually guided stand and squat tasks. The current study, as a follow-up extension, investigates whether lower limb kinematics and muscle activity characterized by electromyography (EMG) signals during monkey performing stand/squat movements can be accurately decoded from neural spike trains in primary motor cortex (M1). Two monkeys were used in this study. Subdermal intramuscular EMG electrodes were implanted to 8 right leg/thigh muscles. With ample data collected from neurons from a large brain area, we performed a spike triggered average (SpTA) analysis and got a series of density contours which revealed the spatial distributions of different muscle-innervating neurons corresponding to each given muscle. Based on the guidance of these results, we identified the locations optimal for chronic electrode implantation and subsequently carried on chronic neural data recordings. A recursive Bayesian estimation framework was proposed for decoding EMG signals together with kinematics from M1 spike trains. Two specific algorithms were implemented: a standard Kalman filter and an unscented Kalman filter. For the latter one, an artificial neural network was incorporated to deal with the nonlinearity in neural tuning. High correlation coefficient and signal to noise ratio between the predicted and the actual data were achieved for both EMG signals and kinematics on both monkeys. Higher decoding accuracy and faster convergence rate could be achieved with the unscented Kalman filter. These results demonstrate that lower limb EMG signals and kinematics during monkey stand/squat can be accurately decoded from a group of M1 neurons with the proposed algorithms. Our findings provide new insights for extending current BMI design concepts and techniques on upper limbs to lower limb circumstances. Brain controlled exoskeleton, prostheses or neuromuscular electrical stimulators for lower limbs are expected to be developed, which enables the subject to manipulate complex biomechatronic devices with mind in more harmonized manner. PMID:28223914
Portnoy, S; Yarnitzky, G; Yizhar, Z; Kristal, A; Oppenheim, U; Siev-Ner, I; Gefen, A
2007-01-01
Fitting of a prosthetic socket is a critical stage in the process of rehabilitation of a trans-tibial amputation (TTA) patient, since a misfit may cause pressure ulcers or a deep tissue injury (DTI: necrosis of the muscle flap under intact skin) in the residual limb. To date, prosthetic fitting typically depends on the subjective skills of the prosthetist, and is not supported by biomedical instrumentation that allows evaluation of the quality of fitting. Specifically, no technology is presently available to provide real-time continuous information on the internal distribution of mechanical stresses in the residual limb during fitting of the prosthesis, or while using it and this severely limits patient evaluations. In this study, a simplified yet clinically oriented patient-specific finite element (FE) model of the residual limb was developed for real-time stress analysis. For this purpose we employed a custom-made FE code that continuously calculates internal stresses in the residual limb, based on boundary conditions acquired in real-time from force sensors, located at the limb-prosthesis interface. Validation of the modeling system was accomplished by means of a synthetic phantom of the residual limb, which allowed simultaneous measurements of interface pressures and internal stresses. Human studies were conducted subsequently in five TTA patients. The dimensions of bones and soft tissues were obtained from X-rays of the residual limb of each patient. An indentation test was performed in order to obtain the effective elastic modulus of the soft tissues of the residual limb. Seven force sensors were placed between the residual limb and the prosthetic liner, and subjects walked on a treadmill during analysis. Generally, stresses under the shinbones were approximately threefold higher than stresses at the soft tissues behind the bones. Usage of a thigh corset decreased the stresses in the residual limb during gait by approximately 80%. Also, the stresses calculated during the trial of a subject who complained about pain and discomfort were the highest, confirming that his socket was not adequately fitted. We conclude that real-time patient-specific FE analysis of internal stresses in deep soft tissues of the residual limb in TTA patients is feasible. This method is promising for improving the fitting of prostheses in the clinical setting and for protecting the residual limb from pressure ulcers and DTI.
Poltawski, Leon; Allison, Rhoda; Briscoe, Simon; Freeman, Jennifer; Kilbride, Cherry; Neal, Debbie; Turton, Ailie J; Dean, Sarah
2016-01-01
Upper limb disability following stroke may have multiple effects on the individual. Existing assessment instruments tend to focus on impairment and function and may miss other changes that are personally important. This study aimed to identify personally significant impacts of upper limb disability following stroke. Accounts by stroke survivors, in the form of web-based diaries (blogs) and stories, were sought using a blog search engine and in stroke-related web-sites. Thematic analysis using the World Health Organisation's International Classification of Functioning Disability and Health (ICF) was used to identify personal impacts of upper limb disability following stroke. Ninety-nine sources from at least four countries were analysed. Many impacts were classifiable using the ICF, but a number of additional themes emerged, including emotional, cognitive and behavioural changes. Blogs and other web-based accounts were easily accessible and rich sources of data, although using them raised several methodological issues, including potential sample bias. A range of impacts was identified, some of which (such as use of information technology and alienation from the upper limb) are not addressed in current assessment instruments. They should be considered in post-stroke assessments. Blogs may help in the development of more comprehensive assessments. A comprehensive assessment of the upper limb following stroke should include the impact of upper limb problems on social participation, as well as associated emotional, cognitive and behavioural changes. Using personalised assessment instruments alongside standardised measures may help ensure that these broader domains are considered in discussions between clinicians and patients. Rehabilitation researchers should investigate whether and how these domains could be addressed and operationalised in standard upper limb assessment instruments.
Chen, Janice D; Falkmer, Torbjörn; Parsons, Richard; Buzzard, Jennifer; Ciccarelli, Marina
2014-05-01
The Rapid Upper Limb Assessment (RULA) is an observation-based screening tool that has been used to assess postural risks of children in school settings. Studies using eye-tracking technology suggest that visual search strategies are influenced by experience in the task performed. This study investigated if experience in postural risk assessments contributed to differences in outcome scores on the RULA and the visual search strategies utilized. While wearing an eye-tracker, 16 student occupational therapists and 16 experienced occupational therapists used the RULA to assess 11 video scenarios of a child using different mobile information and communication technologies (ICT) in the home environment. No significant differences in RULA outcome scores, and no conclusive differences in visual search strategies between groups were found. RULA can be used as a screening tool for postural risks following a short training session regardless of the assessor's experience in postural risk assessments. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Ricci, L; Formica, D; Tamilia, E; Taffoni, F; Sparaci, L; Capirci, O; Guglielmelli, E
2013-01-01
Motion capture based on magneto-inertial sensors is a technology enabling data collection in unstructured environments, allowing "out of the lab" motion analysis. This technology is a good candidate for motion analysis of children thanks to the reduced weight and size as well as the use of wireless communication that has improved its wearability and reduced its obtrusivity. A key issue in the application of such technology for motion analysis is its calibration, i.e. a process that allows mapping orientation information from each sensor to a physiological reference frame. To date, even if there are several calibration procedures available for adults, no specific calibration procedures have been developed for children. This work addresses this specific issue presenting a calibration procedure for motion capture of thorax and upper limbs on healthy children. Reported results suggest comparable performance with similar studies on adults and emphasize some critical issues, opening the way to further improvements.
Warland, Alyson; Paraskevopoulos, Ioannis; Tsekleves, Emmanuel; Ryan, Jennifer; Nowicky, Alexander; Griscti, Josephine; Levings, Hannah; Kilbride, Cherry
2018-04-12
To establish feasibility, acceptability, and preliminary efficacy of an adapted version of a commercially available, virtual-reality gaming system (the Personalised Stroke Therapy system) for upper-limb rehabilitation with community dwelling stroke-survivors. Twelve stroke-survivors (nine females, mean age 58 years, [standard deviation 7.1], median stroke chronicity 42 months [interquartile range 34.7], Motricity index 14-25 for shoulder and elbow) were asked to complete nine, 40-min intervention sessions using two activities on the system over 3 weeks. Feasibility and acceptability were assessed through a semi-structured interview, recording of adverse effects, adherence, enjoyment (using an 11-point Likert scale), and perceived exertion (using the BORG scale). Assessments of impairment (Fugl-Meyer Assessment Upper extremity), activity (ABILHAND, Action Research Arm Test, Motor Activity Log-28), and participation (Subjective Index of Physical and Social Outcome) were completed at baseline, following intervention, and at 4-week follow-up. Data were analysed using Thematic Analysis of interview and intervention field-notes and Wilcoxon Signed Ranks. Side-by-side displays were used to integrate findings. Participants received between 175 and 336 min of intervention. Thirteen non-serious adverse effects were reported by five participants. Participants reported a high level of enjoyment (8.1 and 6.8 out of 10) and rated exertion between 11.6 and 12.9 out of 20. Themes of improvements in impairments and increased spontaneous use in functional activities were identified and supported by improvements in all outcome measures between baseline and post-intervention (p < 0.05 for all measures). Integrated findings suggested that the system is feasible and acceptable for use with a group of community-dwelling stroke-survivors including those with moderately-severe disability. Implications for rehabilitation To ensure feasibility of use and maintenance of an appropriate level of challenge, gaming technologies for use in upper-limb stroke rehabilitation should be personalised, dependent on individual need. Through the use of hands-free systems and personalisation, stroke survivors with moderate and moderately-severe levels of upper-limb impairment following stroke are able to use gaming technologies as a means of delivering upper-limb rehabilitation. Future studies should address issues of acceptability, feasibility, and efficacy of personalised gaming technologies for delivery of upper-limb stroke rehabilitation in the home environment. Findings from this study can be used to develop future games and activities suitable for use in stroke rehabilitation.
A systematic review of propulsion from the flutter kick - What can we learn from the dolphin kick?
Andersen, Jordan T; Sanders, Ross H
2018-09-01
Propulsion, one of the most important factors in front crawl swimming performance, is generated from both the upper and lower limbs, yet little is known about the mechanisms of propulsion from the alternating movements of the lower limbs in the flutter kick (FK). The purpose of this systematic review was to review the literature relating to the mechanisms of propulsion from FK in front crawl. There was limited information about the mechanisms of propulsion in FK. Since movements of the lower limbs are similar between FK and the dolphin kick (DK), mechanisms of propulsion from DK were reviewed to better understand propulsion from FK. Recent evidence suggests that propulsion in DK is generated in conjunction with formation and shedding of vortices. Similar vortex structures have been observed in FK. Visualisation and simulation techniques, such as particle image velocimetry (PIV) and computational fluid dynamics (CFD), are non-invasive tools that can effectively model water flow without impacting swimming technique. These technologies allow researchers to estimate the acceleration of water and, consequently, the propulsive reaction forces acting on the swimmer. Future research should use these technologies to investigate propulsion from FK.
Osteology and radiology of the Maned Wolf (Chrysocyon brachyurus) pelvic limb.
Siqueira, R C; Rahal, S C; Inamassu, L R; Mamprim, M J; Felix, M; Castilho, M S; Mesquita, L R; Ribeiro, V L; Teixeira, C R; Rassy, F B
2017-12-01
This study describes the osteology and radiology of the pelvic limb in maned wolves. Ten (five live and five dead) maned wolves (Chrysocyon brachyurus), five males and five females, aged from 2 to 7 years old were used. Digital radiographs were taken and recorded for both pelvic limbs in all animals. Osteology was correlated with the radiographic images. The pelvis had a rectangular shape, and the obturator foramen (foramen obturatum) was oval. The femoral neck (collum femoris) was short and thick. The greater trochanter (trochanter major) extended proximally to near the dorsum of the femoral head (caput ossis femoris). The lateral femoral condyle (condylus lateralis) was larger than the medial condyle (condylus medialis), and the intercondylar fossa (fossa intercondylaris) had a slightly oblique orientation. The proximal tibia displayed medial and lateral condyles with the medial larger. The femur was slightly shorter than the tibia. Seven tarsal bones (ossa tarsi) were present, four long metatarsal bones (ossa metatarsalia II - V) and a short first metatarsal bone (os metatarsal I). © 2017 Blackwell Verlag GmbH.
Drift-corrected Odin-OSIRIS ozone product: algorithm and updated stratospheric ozone trends
NASA Astrophysics Data System (ADS)
Bourassa, Adam E.; Roth, Chris Z.; Zawada, Daniel J.; Rieger, Landon A.; McLinden, Chris A.; Degenstein, Douglas A.
2018-01-01
A small long-term drift in the Optical Spectrograph and Infrared Imager System (OSIRIS) stratospheric ozone product, manifested mostly since 2012, is quantified and attributed to a changing bias in the limb pointing knowledge of the instrument. A correction to this pointing drift using a predictable shape in the measured limb radiance profile is implemented and applied within the OSIRIS retrieval algorithm. This new data product, version 5.10, displays substantially better both long- and short-term agreement with Microwave Limb Sounder (MLS) ozone throughout the stratosphere due to the pointing correction. Previously reported stratospheric ozone trends over the time period 1984-2013, which were derived by merging the altitude-number density ozone profile measurements from the Stratospheric Aerosol and Gas Experiment (SAGE) II satellite instrument (1984-2005) and from OSIRIS (2002-2013), are recalculated using the new OSIRIS version 5.10 product and extended to 2017. These results still show statistically significant positive trends throughout the upper stratosphere since 1997, but at weaker levels that are more closely in line with estimates from other data records.
Trigsted, Stephanie M; Post, Eric G; Bell, David R
2017-05-01
To determine possible differences in single-hop kinematics and kinetics in females with anterior cruciate ligament reconstruction compared to healthy controls. A second purpose was to make comparisons between the healthy and reconstructed limbs. Subjects were grouped based on surgical status (33 ACLR patients and 31 healthy controls). 3D motion capture synchronized with force plates was used to capture the landing phase of three successful trials of single hop for distance during a single data collection session. Peak values during the loading phase were analysed. Subjects additionally completed three successful trials of the triple hop for distance Tegner activity scale and International Knee Document Committee 2000 (IKDC). Controls demonstrated greater peak knee flexion and greater internal knee extension moment and hip extension moment than ACLR subjects. Within the ACLR group, the healthy limb exhibited greater peak knee flexion, hip flexion, hip extension moment, single hop and triple hops for distance and normalized quadriceps strength. Patients who undergo anterior cruciate ligament reconstruction land in a more extended posture when compared to healthy controls and compared to their healthy limb. III.
The benefit of limb cloud imaging for tropospheric infrared limb sounding
NASA Astrophysics Data System (ADS)
Adams, S.; Spang, R.; Preusse, P.; Heinemann, G.
2009-03-01
Advances in detector technology enable a new generation of infrared limb sounders to measure 2-D images of the atmosphere. A proposed limb cloud imager (LCI) mode will measure clouds with very high spatial resolution. For the inference of temperature and trace gas distributions, detector pixels of the LCI have to be combined into super-pixels which provide the required signal-to-noise ratio and information content for the retrievals. This study examines the extent to which tropospheric coverage can be improved in comparison to limb sounding using a fixed field of view with the size of the super-pixels, as in conventional limb sounders. The study is based on cloud topographies derived from (a) IR brightness temperatures (BT) of geostationary weather satellites in conjunction with ECMWF temperature profiles and (b) ice and liquid water content data of the Consortium for Small-scale Modeling-Europe (COSMO-EU) of the German Weather Service. Limb cloud images are simulated by matching the cloud topography with the limb sounding line of sight (LOS). The analysis of the BT data shows that the reduction of the spatial sampling along the track has hardly any effect on the gain in information. The comparison between BT and COSMO-EU data identifies the strength of both data sets, which are the representation of the horizontal cloud extent for the BT data and the reproduction of the cloud amount for the COSMO-EU data. The results of the analysis of both data sets show the great advantage of the cloud imager. However, because both cloud data sets do not present the complete fine structure of the real cloud fields in the atmosphere it is assumed that the results tend to underestimate the increase in information. In conclusion, real measurements by such an instrument may result in an even higher benefit for tropospheric limb retrievals.
Peikon, Ian D; Fitzsimmons, Nathan A; Lebedev, Mikhail A; Nicolelis, Miguel A L
2009-06-15
Collection and analysis of limb kinematic data are essential components of the study of biological motion, including research into biomechanics, kinesiology, neurophysiology and brain-machine interfaces (BMIs). In particular, BMI research requires advanced, real-time systems capable of sampling limb kinematics with minimal contact to the subject's body. To answer this demand, we have developed an automated video tracking system for real-time tracking of multiple body parts in freely behaving primates. The system employs high-contrast markers painted on the animal's joints to continuously track the three-dimensional positions of their limbs during activity. Two-dimensional coordinates captured by each video camera are combined and converted to three-dimensional coordinates using a quadratic fitting algorithm. Real-time operation of the system is accomplished using direct memory access (DMA). The system tracks the markers at a rate of 52 frames per second (fps) in real-time and up to 100fps if video recordings are captured to be later analyzed off-line. The system has been tested in several BMI primate experiments, in which limb position was sampled simultaneously with chronic recordings of the extracellular activity of hundreds of cortical cells. During these recordings, multiple computational models were employed to extract a series of kinematic parameters from neuronal ensemble activity in real-time. The system operated reliably under these experimental conditions and was able to compensate for marker occlusions that occurred during natural movements. We propose that this system could also be extended to applications that include other classes of biological motion.
Dantzler, William H.; Pannabecker, Thomas L.
2012-01-01
We extended a region-based mathematical model of the renal medulla of the rat kidney, previously developed by us, to represent new anatomic findings on the vascular architecture in the rat inner medulla (IM). In the outer medulla (OM), tubules and vessels are organized around tightly packed vascular bundles; in the IM, the organization is centered around collecting duct clusters. In particular, the model represents the separation of descending vasa recta from the descending limbs of loops of Henle, and the model represents a papillary segment of the descending thin limb that is water impermeable and highly urea permeable. Model results suggest that, despite the compartmentalization of IM blood flow, IM interstitial fluid composition is substantially more homogeneous compared with OM. We used the model to study medullary blood flow in antidiuresis and the effects of vascular countercurrent exchange. We also hypothesize that the terminal aquaporin-1 null segment of the long descending thin limbs may express a urea-Na+ or urea-Cl− cotransporter. As urea diffuses from the urea-rich papillary interstitium into the descending thin limb luminal fluid, NaCl is secreted via the cotransporter against its concentration gradient. That NaCl is then reabsorbed near the loop bend, raising the interstitial fluid osmolality and promoting water reabsorption from the IM collecting ducts. Indeed, the model predicts that the presence of the urea-Na+ or urea- Cl− cotransporter facilitates the cycling of NaCl within the IM and yields a loop-bend fluid composition consistent with experimental data. PMID:22088433
Layton, Anita T; Dantzler, William H; Pannabecker, Thomas L
2012-03-01
We extended a region-based mathematical model of the renal medulla of the rat kidney, previously developed by us, to represent new anatomic findings on the vascular architecture in the rat inner medulla (IM). In the outer medulla (OM), tubules and vessels are organized around tightly packed vascular bundles; in the IM, the organization is centered around collecting duct clusters. In particular, the model represents the separation of descending vasa recta from the descending limbs of loops of Henle, and the model represents a papillary segment of the descending thin limb that is water impermeable and highly urea permeable. Model results suggest that, despite the compartmentalization of IM blood flow, IM interstitial fluid composition is substantially more homogeneous compared with OM. We used the model to study medullary blood flow in antidiuresis and the effects of vascular countercurrent exchange. We also hypothesize that the terminal aquaporin-1 null segment of the long descending thin limbs may express a urea-Na(+) or urea-Cl(-) cotransporter. As urea diffuses from the urea-rich papillary interstitium into the descending thin limb luminal fluid, NaCl is secreted via the cotransporter against its concentration gradient. That NaCl is then reabsorbed near the loop bend, raising the interstitial fluid osmolality and promoting water reabsorption from the IM collecting ducts. Indeed, the model predicts that the presence of the urea-Na(+) or urea- Cl(-) cotransporter facilitates the cycling of NaCl within the IM and yields a loop-bend fluid composition consistent with experimental data.
Results from the July 1981 Workshop on Passive Remote Sensing of the Troposphere
NASA Technical Reports Server (NTRS)
Keafer, L. S., Jr.; Reichle, H. G., Jr.
1982-01-01
Potential roles of passive remote sensors in the study of the chemistry and related dynamics of the lower atmosphere were defined by a Tropospheric Passive Remote Sensing Workshop, and technology advances required to implement these roles were identified. A promising role is in making global-scale, multilayer measurements of the more abundant trace tropospheric gaseous species (e.g., O3, CO, CH4, HNO3) and of aerosol thickness and size distribution. It includes both nadirand limb-viewing measurements. Technology advances focus on both scanning- and fixed-spectra, nadir-viewing techniques with resolutions of 0.1 kaysers or better. Balloon- and Shuttle-borne experiments should be performed to study the effects of instrument noise and background fluctuations on data inversion and to determine the utility of simultaneously obtained nadir- and limb-viewing data.
Bioelectric analyses of an osseointegrated intelligent implant design system for amputees.
Isaacson, Brad M; Stinstra, Jeroen G; MacLeod, Rob S; Webster, Joseph B; Beck, James P; Bloebaum, Roy D
2009-07-15
The projected number of American amputees is expected to rise to 3.6 million by 2050. Many of these individuals depend on artificial limbs to perform routine activities, but prosthetic suspensions using traditional socket technology can prove to be cumbersome and uncomfortable for a person with limb loss. Moreover, for those with high proximal amputations, limited residual limb length may prevent exoprosthesis attachment all together. Osseointegrated implant technology is a novel operative procedure which allows firm skeletal attachment between the host bone and an implant. Preliminary results in European amputees with osseointegrated implants have shown improved clinical outcomes by allowing direct transfer of loads to the bone-implant interface. Despite the apparent advantages of osseointegration over socket technology, the current rehabilitation procedures require long periods of restrictive load bearing prior which may be reduced with expedited skeletal attachment via electrical stimulation. The goal of the osseointegrated intelligent implant design (OIID) system is to make the implant part of an electrical system to accelerate skeletal attachment and help prevent periprosthetic infection. To determine optimal electrode size and placement, we initiated proof of concept with computational modeling of the electric fields and current densities that arise during electrical stimulation of amputee residual limbs. In order to provide insure patient safety, subjects with retrospective computed tomography scans were selected and three dimensional reconstructions were created using customized software programs to ensure anatomical accuracy (Seg3D and SCIRun) in an IRB and HIPAA approved study. These software packages supported the development of patient specific models and allowed for interactive manipulation of electrode position and size. Preliminary results indicate that electric fields and current densities can be generated at the implant interface to achieve the homogenous electric field distributions required to induce osteoblast migration, enhance skeletal fixation and may help prevent periprosthetic infections. Based on the electrode configurations experimented with in the model, an external two band configuration will be advocated in the future.
Emmerson, Kellie B; Harding, Katherine E; Taylor, Nicholas F
2017-08-01
To determine whether patients with stroke receiving rehabilitation for upper limb deficits using smart technology (video and reminder functions) demonstrate greater adherence to prescribed home exercise programmes and better functional outcomes when compared with traditional paper-based exercise prescription. Randomized controlled trial comparing upper limb home exercise programmes supported by video and automated reminders on smart technology, with standard paper-based home exercise programmes. A community rehabilitation programme within a large metropolitan health service. Patients with stroke with upper limb deficits, referred for outpatient rehabilitation. Participants were randomly assigned to the control (paper-based home exercise programme) or intervention group (home exercise programme filmed on an electronic tablet, with an automated reminder). Both groups completed their prescribed home exercise programme for four weeks. The primary outcome was adherence using a self-reported log book. Secondary outcomes were change in upper limb function and patient satisfaction. A total of 62 participants were allocated to the intervention ( n = 30) and control groups ( n = 32). There were no differences between the groups for measures of adherence (mean difference 2%, 95% CI -12 to 17) or change in the Wolf Motor Function Test log transformed time (mean difference 0.02 seconds, 95% CI -0.1 to 0.1). There were no between-group differences in how participants found instructions ( p = 0.452), whether they remembered to do their exercises ( p = 0.485), or whether they enjoyed doing their exercises ( p = 0.864). The use of smart technology was not superior to standard paper-based home exercise programmes for patients recovering from stroke. This trial design was registered prospectively with the Australian and New Zealand Clinical Trials Register, ID: ACTRN 12613000786796. http://www.anzctr.org.au/trialSearch.aspx.
Solar Spicules Near and at the Limb, Observed from Hinode
NASA Technical Reports Server (NTRS)
Sterling, A. C.; Moore, R. L.
2010-01-01
Solar spicules appear as narrow jets emanating from the chromosphere and extending into the corona. They have been observed for over a hundred years, mainly in chromospheric spectral lines such as H-alpha. Because they are at the limit of visibility of ground-based instruments, their nature has long been a puzzle. In recent years however, vast progress has been made in understanding them both theoretically and observationally, as spicule studies have undergone a revolution because of the superior resolution and time cadence of ground-based and space-based instruments. Even more rapid progress is currently underway, due to the Solar Optical Telescope (SOT) instrument on the Hinode spacecraft. Here we present observations of spicules from Hinode SOT, as seen near the limb with the Ca II filtergraph.
Observational Analysis of Coronal Fans
NASA Technical Reports Server (NTRS)
Talpeanu, D.-C.; Rachmeler, L; Mierla, Marilena
2017-01-01
Coronal fans (see Figure 1) are bright observational structures that extend to large distances above the solar surface and can easily be seen in EUV (174 angstrom) above the limb. They have a very long lifetime and can live up to several Carrington rotations (CR), remaining relatively stationary for many months. Note that they are not off-limb manifestation of similarly-named active region fans. The solar conditions required to create coronal fans are not well understood. The goal of this research was to find as many associations as possible of coronal fans with other solar features and to gain a better understanding of these structures. Therefore, we analyzed many fans and created an overview of their properties. We present the results of this statistical analysis and also a case study on the longest living fan.
In Vivo Hypobaric Hypoxia Performed During the Remodeling Process Accelerates Bone Healing in Mice
Durand, Marjorie; Collombet, Jean-Marc; Frasca, Sophie; Begot, Laurent; Lataillade, Jean-Jacques; Le Bousse-Kerdilès, Marie-Caroline
2014-01-01
We investigated the effects of respiratory hypobaric hypoxia on femoral bone-defect repair in mice because hypoxia is believed to influence both mesenchymal stromal cell (MSC) and hematopoietic stem cell mobilization, a process involved in the bone-healing mechanism. To mimic conditions of non-weight-bearing limb immobilization in patients suffering from bone trauma, our hypoxic mouse model was further subjected to hind-limb unloading. A hole was drilled in the right femur of adult male C57/BL6J mice. Four days after surgery, mice were subjected to hind-limb unloading for 1 week. Seven days after surgery, mice were either housed for 4 days in a hypobaric room (FiO2 at 10%) or kept under normoxic conditions. Unsuspended control mice were housed in either hypobaric or normoxic conditions. Animals were sacrificed on postsurgery day 11 to allow for collection of both contralateral and lesioned femurs, blood, and spleen. As assessed by microtomography, delayed hypoxia enhanced bone-healing efficiency by increasing the closing of the cortical defect and the newly synthesized bone volume in the cavity by +55% and +35%, respectively. Proteome analysis and histomorphometric data suggested that bone-repair improvement likely results from the acceleration of the natural bone-healing process rather than from extended mobilization of MSC-derived osteoprogenitors. Hind-limb unloading had hardly any effect beyond delayed hypoxia-enhanced bone-healing efficiency. PMID:24944208
Functional versus effector-specific organization of the human posterior parietal cortex: revisited
Leone, Frank T. M.; Medendorp, W. Pieter
2016-01-01
It has been proposed that the posterior parietal cortex (PPC) is characterized by an effector-specific organization. However, strikingly similar functional MRI (fMRI) activation patterns have been found in the PPC for hand and foot movements. Because the fMRI signal is related to average neuronal activity, similar activation levels may result either from effector-unspecific neurons or from intermingled subsets of effector-specific neurons within a voxel. We distinguished between these possibilities using fMRI repetition suppression (RS). Participants made delayed, goal-directed eye, hand, and foot movements to visual targets. In each trial, the instructed effector was identical or different to that of the previous trial. RS effects indicated an attenuation of the fMRI signal in repeat trials. The caudal PPC was active during the delay but did not show RS, suggesting that its planning activity was effector independent. Hand and foot-specific RS effects were evident in the anterior superior parietal lobule (SPL), extending to the premotor cortex, with limb overlap in the anterior SPL. Connectivity analysis suggested information flow between the caudal PPC to limb-specific anterior SPL regions and between the limb-unspecific anterior SPL toward limb-specific motor regions. These results underline that both function and effector specificity should be integrated into a concept of PPC action representation not only on a regional but also on a fine-grained, subvoxel level. PMID:27466132
Safayi, Sina; Jeffery, Nick D; Shivapour, Sara K; Zamanighomi, Mahdi; Zylstra, Tyler J; Bratsch-Prince, Joshua; Wilson, Saul; Reddy, Chandan G; Fredericks, Douglas C; Gillies, George T; Howard, Matthew A
2015-11-15
We are developing a novel intradural spinal cord (SC) stimulator designed to improve the treatment of intractable pain and the sequelae of SC injury. In-vivo ovine models of neuropathic pain and moderate SC injury are being implemented for pre-clinical evaluations of this device, to be carried out via gait analysis before and after induction of the relevant condition. We extend previous studies on other quadrupeds to extract the three-dimensional kinematics of the limbs over the gait cycle of sheep walking on a treadmill. Quantitative measures of thoracic and pelvic limb movements were obtained from 17 animals. We calculated the total-error values to define the analytical performance of our motion capture system for these kinematic variables. The post- vs. pre-injury time delay between contralateral thoracic and pelvic-limb steps for normal and SC-injured sheep increased by ~24s over 100 steps. The pelvic limb hoof velocity during swing phase decreased, while range of pelvic hoof elevation and distance between lateral pelvic hoof placements increased after SC injury. The kinematics measures in a single SC-injured sheep can be objectively defined as changed from the corresponding pre-injury values, implying utility of this method to assess new neuromodulation strategies for specific deficits exhibited by an individual. Copyright © 2015 Elsevier B.V. All rights reserved.
Weiss, Patrice L.; Keshner, Emily A.
2015-01-01
The primary focus of rehabilitation for individuals with loss of upper limb movement as a result of acquired brain injury is the relearning of specific motor skills and daily tasks. This relearning is essential because the loss of upper limb movement often results in a reduced quality of life. Although rehabilitation strives to take advantage of neuroplastic processes during recovery, results of traditional approaches to upper limb rehabilitation have not entirely met this goal. In contrast, enriched training tasks, simulated with a wide range of low- to high-end virtual reality–based simulations, can be used to provide meaningful, repetitive practice together with salient feedback, thereby maximizing neuroplastic processes via motor learning and motor recovery. Such enriched virtual environments have the potential to optimize motor learning by manipulating practice conditions that explicitly engage motivational, cognitive, motor control, and sensory feedback–based learning mechanisms. The objectives of this article are to review motor control and motor learning principles, to discuss how they can be exploited by virtual reality training environments, and to provide evidence concerning current applications for upper limb motor recovery. The limitations of the current technologies with respect to their effectiveness and transfer of learning to daily life tasks also are discussed. PMID:25212522
Recent advancements in prosthetic hand technology.
Saikia, Angana; Mazumdar, Sushmi; Sahai, Nitin; Paul, Sudip; Bhatia, Dinesh; Verma, Suresh; Rohilla, Punit Kumar
2016-07-01
Recently, significant advances over the past decade have been made in robotics, artificial intelligence and other cognitive related fields, allowing development of highly sophisticated bio-mimetic robotics systems. In addition, enormous number of robots have been designed and assembled by explicitly realising their biological oriented behaviours. To enhance skill behaviours and adequate grasping abilities in these devices, a new phase of dexterous hands has been developed recently with bio-mimetically oriented and bio-inspired functionalities. The aim in writing this review paper is to present a detailed insight towards the development of the bio-mimetic based dexterous robotic multi-fingered artificial hand. An "ideal" upper limb prosthesis should be perceived as a part of their natural body by the amputee and should replicate sensory-motor capabilities of the amputated limb. Upper-limb amputations are most often the result of sudden trauma to the body, although they also can be caused by malignancy, congenital deficiencies and vascular diseases. This paper discusses the different bio-mimetic approaches using a framework that permits for a common description of biological and technical based hand manipulation behaviour. In particular, the review focuses on a number of developments in the inspired robotic systems. In conclusion, the study found that a huge amount of research efforts in terms of kinematics, dynamics, modelling and control methodologies are being put in to improve the present hand technology, thereby providing more functionality to the prosthetic limb of the amputee. This would improve their quality-of-life and help in performing activities of daily living (ADL) tasks with comparative ease in the near future.
[Research on Control System of an Exoskeleton Upper-limb Rehabilitation Robot].
Wang, Lulu; Hu, Xin; Hu, Jie; Fang, Youfang; He, Rongrong; Yu, Hongliu
2016-12-01
In order to help the patients with upper-limb disfunction go on rehabilitation training,this paper proposed an upper-limb exoskeleton rehabilitation robot with four degrees of freedom(DOF),and realized two control schemes,i.e.,voice control and electromyography control.The hardware and software design of the voice control system was completed based on RSC-4128 chips,which realized the speech recognition technology of a specific person.Besides,this study adapted self-made surface eletromyogram(sEMG)signal extraction electrodes to collect sEMG signals and realized pattern recognition by conducting sEMG signals processing,extracting time domain features and fixed threshold algorithm.In addition,the pulse-width modulation(PWM)algorithm was used to realize the speed adjustment of the system.Voice control and electromyography control experiments were then carried out,and the results showed that the mean recognition rate of the voice control and electromyography control reached 93.1%and 90.9%,respectively.The results proved the feasibility of the control system.This study is expected to lay a theoretical foundation for the further improvement of the control system of the upper-limb rehabilitation robot.
Hale, Leigh A; Satherley, Jessica A; McMillan, Nicole J; Milosavljevic, Stephan; Hijmans, Juha M; King, Marcus J
2012-01-01
This article reports on the perceptions of 14 adults with chronic stroke who participated in a pilot study to determine the utility, acceptability, and potential efficacy of using an adapted CyWee Z handheld game controller to play a variety of computer games aimed at improving upper-limb function. Four qualitative in-depth interviews and two focus groups explored participant perceptions. Data were thematically analyzed with the general inductive approach. Participants enjoyed playing the computer games with the technology. The perceived benefits included improved upper-limb function, concentration, and balance; however, six participants reported shoulder and/or arm pain or discomfort, which presented while they were engaged in play but appeared to ease during rest. Participants suggested changes to the games and provided opinions on the use of computer games in rehabilitation. Using an adapted CyWee Z controller and computer games in upper-limb rehabilitation for people with chronic stroke is an acceptable and potentially beneficial adjunct to rehabilitation. The development of shoulder pain was a negative side effect for some participants and requires further investigation.
Hybrid Orientation Based Human Limbs Motion Tracking Method
Glonek, Grzegorz; Wojciechowski, Adam
2017-01-01
One of the key technologies that lays behind the human–machine interaction and human motion diagnosis is the limbs motion tracking. To make the limbs tracking efficient, it must be able to estimate a precise and unambiguous position of each tracked human joint and resulting body part pose. In recent years, body pose estimation became very popular and broadly available for home users because of easy access to cheap tracking devices. Their robustness can be improved by different tracking modes data fusion. The paper defines the novel approach—orientation based data fusion—instead of dominating in literature position based approach, for two classes of tracking devices: depth sensors (i.e., Microsoft Kinect) and inertial measurement units (IMU). The detailed analysis of their working characteristics allowed to elaborate a new method that let fuse more precisely limbs orientation data from both devices and compensates their imprecisions. The paper presents the series of performed experiments that verified the method’s accuracy. This novel approach allowed to outperform the precision of position-based joints tracking, the methods dominating in the literature, of up to 18%. PMID:29232832
Second-Generation Six-Limbed Experimental Robot
NASA Technical Reports Server (NTRS)
Kennedy, Brett; Okon, Avi; Aghazarian, Hrand; Robinson, Matthew; Garrett, Michael; Magnone, Lee
2004-01-01
The figure shows the LEMUR II - the second generation of the Limbed Excursion Mechanical Utility Robot (LEMUR), which was described in "Six-Legged Experimental Robot" (NPO-20897), NASA Tech Briefs, Vol. 25, No. 12 (December 2001), page 58. The LEMUR II incorporates a number of improvements, including new features, that extend its capabilities beyond those of its predecessor, which is now denoted the LEMUR I. To recapitulate: the LEMUR I was a six-limbed robot for demonstrating robotic capabilities for assembly, maintenance, and inspection. The LEMUR I was designed to be capable of walking autonomously along a truss structure toward a mechanical assembly at a prescribed location and to perform other operations. The LEMUR I was equipped with stereoscopic video cameras and image-data-processing circuitry for navigation and mechanical operations. It was also equipped with a wireless modem, through which it could be commanded remotely. Upon arrival at a mechanical assembly, the LEMUR I would perform simple mechanical operations with one or both of its front limbs. It could also transmit images to a host computer. Each of the six limbs of the LEMUR I was operated independently. Each of the four rear limbs had three degrees of freedom (DOFs), while each of the front two limbs had four DOFs. The front two limbs were designed to hold, operate, and/or be integrated with tools. The LEMUR I included an onboard computer equipped with an assortment of digital control circuits, digital input/output circuits, analog-to-digital converters for input, and digital-to-analog (D/A) converters for output. Feedback from optical encoders in the limb actuators was utilized for closed-loop microcomputer control of the positions and velocities of the actuators. The LEMUR II incorporates the following improvements over the LEMUR I: a) The drive trains for the joints of the LEMUR II are more sophisticated, providing greater torque and accuracy. b) The six limbs are arranged symmetrically about a hexagonal body platform instead of in straight lines along the sides. This symmetrical arrangement is more conducive to omnidirectional movement in a plane. c) The number of degrees of freedom of each of the rear four limbs has been increased by one. Now, every limb has four degrees of freedom: three at the hip (or shoulder, depending on one s perspective) and one at the knee (or elbow, depending on one s perspective). d) Now every limb (instead of only the two front limbs) can perform operations. For this purpose, each limb is tipped with an improved quick-release mechanism for swapping of end-effector tools. e) New end-effector tools have been developed. These include an instrumented rotary driver that accepts all tool bits that have 0.125-in. (3.175-mm)-diameter shanks, a charge-coupled-device video camera, a super bright light-emitting diode for illuminating the work area of the robot, and a generic collet tool that can be quickly and inexpensively modified to accept any cylindrical object up to 0.5 in. (12.7 mm) in diameter. f) The stereoscopic cameras are mounted on a carriage that moves along a circular track, thereby providing for omnidirectional machine vision. g) The control software has been augmented with software that implements innovations reported in two prior NASA Tech Briefs articles: the HIPS algorithm ["Hybrid Image-Plane/Stereo Manipulation" (NPO-30492), Vol. 28, No. 7 (July 2004), page 55] and the CAMPOUT architecture ["An Architecture for Controlling Multiple Robots" (NPO-30345), Vol. 28, No. 10 (October 2004), page 65].
Therapists’ Perceptions of Social Media and Video Game Technologies in Upper Limb Rehabilitation
Shirzad, Navid; Lohse, Keith R; Virji-Babul, Naznin; Hoens, Alison M; Holsti, Liisa; Li, Linda C; Miller, Kimberly J; Lam, Melanie Y; Van der Loos, HF Machiel
2015-01-01
Background The application of technologies, such as video gaming and social media for rehabilitation, is garnering interest in the medical field. However, little research has examined clinicians’ perspectives regarding technology adoption by their clients. Objective The objective of our study was to explore therapists’ perceptions of how young people and adults with hemiplegia use gaming and social media technologies in daily life and in rehabilitation, and to identify barriers to using these technologies in rehabilitation. Methods We conducted two focus groups comprised of ten occupational therapists/physiotherapists who provide neurorehabilitation to individuals with hemiplegia secondary to stroke or cerebral palsy. Data was analyzed using inductive thematic analysis. The diffusion of innovations theory provided a framework to interpret emerging themes. Results Therapists were using technology in a limited capacity. They identified barriers to using social media and gaming technology with their clients, including a lack of age appropriateness, privacy issues with social media, limited transfer of training, and a lack of accessibility of current systems. Therapists also questioned their role in the context of technology-based interventions. The opportunity for social interaction was perceived as a major benefit of integrated gaming and social media. Conclusions This study reveals the complexities associated with adopting new technologies in clinical practice, including the need to consider both client and clinician factors. Despite reporting several challenges with applying gaming and social media technology with clinical populations, therapists identified opportunities for increased social interactions and were willing to help shape the development of an upper limb training system that could more readily meet the needs of clients with hemiplegia. By considering the needs of both therapists and clients, technology developers may increase the likelihood that clinicians will adopt innovative technologies. PMID:25759148
Therapists' perceptions of social media and video game technologies in upper limb rehabilitation.
Tatla, Sandy K; Shirzad, Navid; Lohse, Keith R; Virji-Babul, Naznin; Hoens, Alison M; Holsti, Liisa; Li, Linda C; Miller, Kimberly J; Lam, Melanie Y; Van der Loos, H F Machiel
2015-03-10
The application of technologies, such as video gaming and social media for rehabilitation, is garnering interest in the medical field. However, little research has examined clinicians' perspectives regarding technology adoption by their clients. The objective of our study was to explore therapists' perceptions of how young people and adults with hemiplegia use gaming and social media technologies in daily life and in rehabilitation, and to identify barriers to using these technologies in rehabilitation. We conducted two focus groups comprised of ten occupational therapists/physiotherapists who provide neurorehabilitation to individuals with hemiplegia secondary to stroke or cerebral palsy. Data was analyzed using inductive thematic analysis. The diffusion of innovations theory provided a framework to interpret emerging themes. Therapists were using technology in a limited capacity. They identified barriers to using social media and gaming technology with their clients, including a lack of age appropriateness, privacy issues with social media, limited transfer of training, and a lack of accessibility of current systems. Therapists also questioned their role in the context of technology-based interventions. The opportunity for social interaction was perceived as a major benefit of integrated gaming and social media. This study reveals the complexities associated with adopting new technologies in clinical practice, including the need to consider both client and clinician factors. Despite reporting several challenges with applying gaming and social media technology with clinical populations, therapists identified opportunities for increased social interactions and were willing to help shape the development of an upper limb training system that could more readily meet the needs of clients with hemiplegia. By considering the needs of both therapists and clients, technology developers may increase the likelihood that clinicians will adopt innovative technologies.
Lung Metastasis Mimicking Fingertip Infection
Soylemez, Salih; Demiroglu, Murat; Yayla, Mehmet Ali; Ozkan, Korhan; Alpan, Bugra; Ozger, Harzem
2015-01-01
Metastasis fingers (acral metastasis) are finding a poor prognosis. Past medical history should be questioned and metastasis from primary tumor should be kept in mind in patients with pain, swelling, and hyperemia in fingers. Successful surgical treatment on acral metastasis does not extend the life expectancy; however, it reduces the patient's pain during his terminal period, saves the functions of the limb, and increases life comfort. PMID:26236517
NASA Astrophysics Data System (ADS)
Clancy, R. T.; Smith, M. D.; Wolff, M. J.; Toigo, A. D.; Seelos, K. D.; Murchie, S. L.
2016-12-01
Since 2009, the CRISM visible-nearIR imaging spectrometer onboard the Mars Reconnaissance Orbiter (MRO) has returned over 70 orbits of Mars limb image scans over the 0-130 km altitude range. Pole-to-pole latitudinal coverage is obtained from the near-polar, sun-synchronous (LT 3pm) MRO orbit for a limited set of surface longitudes centered on Tharsis, Valles Mariners, Meridioni, and Hellas regions. Seasonal coverage extends over the full seasonal range (Ls=0-360°), as accumulated over 2009-2016 (MY 29-33), supporting a range of aerosol and airglow studies (Smith et al., 2013; Clancy et al., 2012, 2013). The 0.4-4.0 μm wavelength range of these CRISM limb observations proves particularly suitable to characterizing aerosol composition and particle sizes, particularly for the Mars mesosphere (z=50-100 km), which has only recently been observed with any dedication by MCS (Sefton-Nash et al, 2013) and CRISM limb measurements. Dust and H2O, CO2 ice aerosols are clearly distinguished by their distinct scattering and absorption behaviors over the key 2-4 μm wavelength region, and their particle sizes are well determined by the 0.4-3 μm wavelength region. Several key attributes are determined for Mars mesospheric aerosols. Dust aerosols are largely undetected, and are apparently injected to such heights only during global dust storms (Clancy et al, 2010). Ice clouds are generally common at 55-75 km altitudes, although in separate halves of the Mars year. CO2 and H2O ice clouds are most prominent during the aphelion and perihelion portions of the Mars orbit, respectively. CO2 ice clouds, which occur at low latitudes over specific surface longitudes, present distinct particle size populations ranging from 0.5 to 1.5 μm (Reff). Mesospheric H2O ice clouds exhibit somewhat smaller particle sizes (Reff=0.3-1 μm) and extend over low to mid latitudes. This orbital dependence for mesospheric ice aerosol composition indicates extreme annual (orbital) variation in mesospheric water vapor.
NASA Astrophysics Data System (ADS)
Park, Ji Hyung; Seo, Dong-Hyun; Cho, Seungkwan; Kim, Seo-Hyun; Eom, Sinae; Kim, Han Sung
2015-09-01
Musculoskeletal disorders during and after spaceflight are considered as a serious health issue. In space, weight-bearing exercise recognized as the main countermeasure to bone loss, since many anti-resorptive medications have not yet been approved for spaceflight or have been unsuccessful in their limited application. We need to investigate a complementary or alternative way to prevent bone loss and muscle atrophy resulting from microgravity condition. Partial vibration was chosen because it is one of the most feasible ways to adopt safely and effectively. Moreover, although the influence of hind-limb suspension has been studied in both male and female rodents, only rarely are both genders evaluated in the same study. Thus, to further extend our knowledge, the present study performed comparative analysis between genders. A total of 36 12-week-old male and female Sprague-Dawley rats were used and were randomly assigned to control (CON), hind-limb suspension without vibration stimulus (HS), and hind-limb suspension with vibration stimulus (HV) groups. Hind-limb suspension has led to increasing the rate of bone loss and muscle atrophy regardless of gender. The rates of bone loss in male group obviously increased than that of female group. All structural parameters were showed significant difference between HS and HV ( p < 0.05) in male group whereas there are no significant differences in female group. In female, the muscle volume with treatment of partial vibration stimulus significantly increased which compared with that of hind-limb suspension ( p < 0.05) whereas there are no significant differences in male group. Thus partial vibration could prevent bone loss of tibia in males and muscle atrophy in females induced by hind-limb suspension. In other words, partial vibration has positive effects on damaged musculoskeletal tissues that differ based on gender.
Kato, Norio; Tanaka, Toshiaki; Sugihara, Syunichi; Shimizu, Koichi
2015-01-01
[Purpose] The purpose of this study was to develop a new telerehabilitation system based on VR technology for training of paralyzed upper and lower extremities and poor balance in patients with stroke. Moreover, the effectiveness of the system was verified by analysis of the recovery of these patients. [Subjects] Five healthy persons and five people with motor paralysis, caused by cerebrovascular disease, participated. [Methods] The features of our system are as follows: (1) Our system can train upper and lower limbs and balancing with 3D images. (2) A Kinect® is used for user posture detection. (3) A vibrator is used for feedback to a sensory receptor in order to promote the learning effect of motion. Upper limb and balance training were conducted in this study. [Results] The time necessary for the upper limb and balance training tasks was shortened for the participants with disabilities. The joint angle for the participants with disabilities tended to equate to that of the healthy participants over time. Moreover, our system had no side effects. [Conclusion] These points suggest that our system is effective and safe. The user interface and assessment of the conditions of patients from a distance should be studied in the future. PMID:26644671
Mastinu, Enzo; Doguet, Pascal; Botquin, Yohan; Hakansson, Bo; Ortiz-Catalan, Max
2017-08-01
Despite the technological progress in robotics achieved in the last decades, prosthetic limbs still lack functionality, reliability, and comfort. Recently, an implanted neuromusculoskeletal interface built upon osseointegration was developed and tested in humans, namely the Osseointegrated Human-Machine Gateway. Here, we present an embedded system to exploit the advantages of this technology. Our artificial limb controller allows for bioelectric signals acquisition, processing, decoding of motor intent, prosthetic control, and sensory feedback. It includes a neurostimulator to provide direct neural feedback based on sensory information. The system was validated using real-time tasks characterization, power consumption evaluation, and myoelectric pattern recognition performance. Functionality was proven in a first pilot patient from whom results of daily usage were obtained. The system was designed to be reliably used in activities of daily living, as well as a research platform to monitor prosthesis usage and training, machine-learning-based control algorithms, and neural stimulation paradigms.
ATHLETE as a Mobile ISRU and Regolith Construction Platform
NASA Technical Reports Server (NTRS)
Howe, A. Scott; Wilcox, Brian; Barmatz, Martin; Voecks, Gerald
2016-01-01
The All-Terrain Hex-Limbed Extra-Terrestrial Explorer (ATHLETE) robotic mobility platform can provide precision positioning and mobility for site preparation and regolith construction needs. ATHLETE is a multi-use platform designed to use swap-out tools and implements that can be applied to any number of tasks that need precision limb manipulation or mobility. Major capabilities include off-loading habitats, transporting surface assets, robotically assembling outposts from multiple mission manifests, and supporting science and technology objectives. This paper describes conceptual approaches for supporting NASA regolith construction research, such as additive construction, modular brick and panel factory, and mobile ISRU platform.
Powered lower limb orthoses for gait rehabilitation
Ferris, Daniel P.; Sawicki, Gregory S.; Domingo, Antoinette
2006-01-01
Bodyweight supported treadmill training has become a prominent gait rehabilitation method in leading rehabilitation centers. This type of locomotor training has many functional benefits but the labor costs are considerable. To reduce therapist effort, several groups have developed large robotic devices for assisting treadmill stepping. A complementary approach that has not been adequately explored is to use powered lower limb orthoses for locomotor training. Recent advances in robotic technology have made lightweight powered orthoses feasible and practical. An advantage to using powered orthoses as rehabilitation aids is they allow practice starting, turning, stopping, and avoiding obstacles during overground walking. PMID:16568153
Design features of implants for direct skeletal attachment of limb prostheses
Pitkin, M.
2013-01-01
In direct skeletal attachment (DSA) of limb prostheses, a construct is implanted into an amputee’s residuum bone and protrudes out of the residuum’s skin. This technology represents an alternative to traditional suspension of prostheses via various socket systems, with clear indications when the sockets cannot be properly fitted. Contemporary DSA was invented in the 1990s, and several implant systems have been introduced since then. The current review is intended to compare the design features of implants for DSA whose use in humans or in animal studies has been reported in the literature. PMID:23554122
NASA Technical Reports Server (NTRS)
Acton, C. H., Jr.; Ohtakay, H.
1975-01-01
Optical navigation uses spacecraft television pictures of a target body against a known star background in a process which relates the spacecraft trajectory to the target body. This technology was used in the Mariner-Venus-Mercury mission, with the optical data processed in near-real-time, simulating a mission critical environment. Optical data error sources were identified, and a star location error analysis was carried out. Several methods for selecting limb crossing coordinates were used, and a limb smear compensation was introduced. Omission of planetary aberration corrections was the source of large optical residuals.
Yasue, Akihiro; Mitsui, Silvia Naomi; Watanabe, Takahito; Sakuma, Tetsushi; Oyadomari, Seiichi; Yamamoto, Takashi; Noji, Sumihare; Mito, Taro; Tanaka, Eiji
2014-07-16
Since the establishment of embryonic stem (ES) cell lines, the combined use of gene targeting with homologous recombination has aided in elucidating the functions of various genes. However, the ES cell technique is inefficient and time-consuming. Recently, two new gene-targeting technologies have been developed: the transcription activator-like effector nuclease (TALEN) system, and the clustered regularly interspaced short palindromic repeat (CRISPR)/CRISPR-associated protein (Cas) system. In addition to aiding researchers in solving conventional problems, these technologies can be used to induce site-specific mutations in various species for which ES cells have not been established. Here, by targeting the Fgf10 gene through RNA microinjection in one-cell mouse embryos with the TALEN and CRISPR/Cas systems, we produced the known limb-defect phenotypes of Fgf10-deficient embryos at the F0 generation. Compared to the TALEN system, the CRISPR/Cas system induced the limb-defect phenotypes with a strikingly higher efficiency. Our results demonstrate that although both gene-targeting technologies are useful, the CRISPR/Cas system more effectively elicits single-step biallelic mutations in mice.
Hox gene expression in the specialized limbs of the Iberian mole (Talpa occidentalis).
Bickelmann, Constanze; van der Vos, Wessel; de Bakker, Merijn A G; Jiménez, Rafael; Maas, Saskia; Sánchez-Villagra, Marcelo R
2017-01-01
Fossorial talpid moles use their limbs predominantly for digging, which explains their highly specialized anatomy. The humerus is particularly short and dorsoventrally rotated, with broadened distal and proximal parts where muscles attach and which facilitate powerful abductive movements. The radius and ulna are exceptionally robust and short. The ulna has an expanded olecranon process. The femur is generalized, but the fused tibia-fibula complex is short and robust. To understand the developmental bases of these specializations, we studied expression patterns of four 5' Hox genes in the fossorial Iberian mole (Talpa occidentalis). These genes are known to play major roles in patterning the developing limb skeleton in the mouse, with which comparisons were made (Mus musculus, C57BL/6Jico strain). We find that HoxA9 expression is spatially expanded in the developing stylopodial area in the mole forelimb, compared to the less specialized mouse forelimb and mole hind limb. HoxD9 expression does not extend into the thoracic body wall in the mole forelimb in contrast to the mouse, and is also reduced in the presumptive zeugopodium in mole forelimb, compared to mouse. Expression of HoxD11 is upregulated in the mole in the postaxial area of the hind limb zeugopod, compared to the mouse. On the other hand, HoxD13 is downregulated in the postaxial zeugopodial area in the forelimb of the mole, compared to the mouse. The differences in the expression patterns of these 5' Hox genes between Talpa and Mus are an indication of the developmental changes going hand in hand with anatomical digging adaptations in the mole adult. © 2016 Wiley Periodicals, Inc.
Allen, Marcus; Zhong, Qiang; Kirsch, Nicholas; Dani, Ashwin; Clark, William W; Sharma, Nitin
2017-12-01
Miniature inertial measurement units (IMUs) are wearable sensors that measure limb segment or joint angles during dynamic movements. However, IMUs are generally prone to drift, external magnetic interference, and measurement noise. This paper presents a new class of nonlinear state estimation technique called state-dependent coefficient (SDC) estimation to accurately predict joint angles from IMU measurements. The SDC estimation method uses limb dynamics, instead of limb kinematics, to estimate the limb state. Importantly, the nonlinear limb dynamic model is formulated into state-dependent matrices that facilitate the estimator design without performing a Jacobian linearization. The estimation method is experimentally demonstrated to predict knee joint angle measurements during functional electrical stimulation of the quadriceps muscle. The nonlinear knee musculoskeletal model was identified through a series of experiments. The SDC estimator was then compared with an extended kalman filter (EKF), which uses a Jacobian linearization and a rotation matrix method, which uses a kinematic model instead of the dynamic model. Each estimator's performance was evaluated against the true value of the joint angle, which was measured through a rotary encoder. The experimental results showed that the SDC estimator, the rotation matrix method, and EKF had root mean square errors of 2.70°, 2.86°, and 4.42°, respectively. Our preliminary experimental results show the new estimator's advantage over the EKF method but a slight advantage over the rotation matrix method. However, the information from the dynamic model allows the SDC method to use only one IMU to measure the knee angle compared with the rotation matrix method that uses two IMUs to estimate the angle.
Initial evaluation of a canine stifle arthrotomy post-operative pain model.
Tomas, A; Bledsoe, D; Wall, S; Davidson, G; Lascelles, B D X
2015-06-01
Most models of acute post-operative orthopedic pain involve the injection of a clinically irrelevant pro-inflammatory agent. The ideal model should, however, be clinically relevant and allow full functional recovery of enrolled animals after research is completed. This study explored the validity of a model employing arthrotomy and objectively measured limb use. Six purpose-bred Beagles underwent arthrotomies on each stifle with a washout period in between. Using a randomized crossover design, each dog received placebo and an extended-release buprenorphine (ER-Bup) preparation. Static and dynamic ground reaction forces (GRFs) were measured prior to and for 72 h following surgery using a pressure sensitive walkway (PSW). GRFs for each hind limb were compared using difference (delta), and symmetry indices (SI). The effects of surgery and of treatment were analyzed using repeated measures ANCOVA. The results indicated significantly decreased limb use compared to baseline for placebo, and significantly increased limb use in the ER-Bup group over placebo at all times for % bodyweight distribution (%BWdistrib), peak vertical force (PVF) and vertical impulse (VI). There was a significant treatment by time interaction for velocity (P = 0.03) and %BWdistrib (P = 0.01, 0.003). Overall, the data show that reduced limb use was present for at least 72 h following arthrotomy. In addition, the use of the ER-Bup analgesic decreased lameness, confirming the validity of this approach as a model of post-operative pain. Subjective assessments did not detect the pain-inducing effects of arthrotomy or pain-alleviating effects of treatment, and subjective measures of procedural pain in research dogs need to be developed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Contino, E K; King, M R; Valdés-Martínez, A; McIlwraith, C W
2015-03-01
Hindlimb proximal suspensory desmopathy is a common injury of sport horses but diagnosis can be difficult because diagnostic analgesia of the region lacks specificity. Perineural analgesia of the deep branch of the lateral plantar nerve (DBLPN) has been proposed as a more specific method of isolating pain of the proximal aspect of the suspensory ligament but the technique has not been evaluated in vivo. To determine the extent of diffusion of contrast medium and mepivacaine following DBLPN analgesia using a single-needle injection technique and to determine if there is inadvertent involvement of the tarsal sheath and/or tarsometatarsal (TMT) joint using this technique. In vivo experimental study. Perineural injection of the DBLPN was performed in 16 limbs with 3 ml of either mepivacaine hydrochloride or positive contrast medium. Contrast medium-injected limbs were radiographed 5, 15, and 30 min post injection and diffusion characteristics were described. In mepivacaine-injected limbs, synovial fluid from the TMT joint was obtained 10 and 20 min post injection and mepivacaine concentrations were analysed. At 5, 15 and 30 min post injection, the contrast medium extended, on average, 19.6, 20.6 and 21.0 mm proximal and 38.0, 43.5 and 51.9 mm distal to the injection site, respectively. Three of 8 (37.5%) limbs had evidence of contrast medium in the tarsal sheath. Two of 8 (25%) limbs had mepivacaine concentrations within the TMT joint sufficient to produce analgesia (>300 mg/l) at 10 min post injection. Contrast medium diffused further in a distal direction than in a proximal direction. Analgesia of the DBLPN can result in inadvertent involvement of the tarsal sheath and/or TMT joint. © 2014 EVJ Ltd.
Miralles, Aurélien; Hipsley, Christy A.; Erens, Jesse; Gehara, Marcelo; Rakotoarison, Andolalao; Glaw, Frank; Müller, Johannes; Vences, Miguel
2015-01-01
Scincine lizards in Madagascar form an endemic clade of about 60 species exhibiting a variety of ecomorphological adaptations. Several subclades have adapted to burrowing and convergently regressed their limbs and eyes, resulting in a variety of partial and completely limbless morphologies among extant taxa. However, patterns of limb regression in these taxa have not been studied in detail. Here we fill this gap in knowledge by providing a phylogenetic analysis of DNA sequences of three mitochondrial and four nuclear gene fragments in an extended sampling of Malagasy skinks, and microtomographic analyses of osteology of various burrowing taxa adapted to sand substrate. Based on our data we propose to (i) consider Sirenoscincus Sakata & Hikida, 2003, as junior synonym of Voeltzkowia Boettger, 1893; (ii) resurrect the genus name Grandidierina Mocquard, 1894, for four species previously included in Voeltzkowia; and (iii) consider Androngo Brygoo, 1982, as junior synonym of Pygomeles Grandidier, 1867. By supporting the clade consisting of the limbless Voeltzkowia mira and the forelimb-only taxa V. mobydick and V. yamagishii, our data indicate that full regression of limbs and eyes occurred in parallel twice in the genus Voeltzkowia (as hitherto defined) that we consider as a sand-swimming ecomorph: in the Voeltzkowia clade sensu stricto the regression first affected the hindlimbs and subsequently the forelimbs, whereas the Grandidierina clade first regressed the forelimbs and subsequently the hindlimbs following the pattern prevalent in squamates. Timetree reconstructions for the Malagasy Scincidae contain a substantial amount of uncertainty due to the absence of suitable primary fossil calibrations. However, our preliminary reconstructions suggest rapid limb regression in Malagasy scincids with an estimated maximal duration of 6 MYr for a complete regression in Paracontias, and 4 and 8 MYr respectively for complete regression of forelimbs in Grandidierina and hindlimbs in Voeltzkowia. PMID:26042667
Miralles, Aurélien; Hipsley, Christy A; Erens, Jesse; Gehara, Marcelo; Rakotoarison, Andolalao; Glaw, Frank; Müller, Johannes; Vences, Miguel
2015-01-01
Scincine lizards in Madagascar form an endemic clade of about 60 species exhibiting a variety of ecomorphological adaptations. Several subclades have adapted to burrowing and convergently regressed their limbs and eyes, resulting in a variety of partial and completely limbless morphologies among extant taxa. However, patterns of limb regression in these taxa have not been studied in detail. Here we fill this gap in knowledge by providing a phylogenetic analysis of DNA sequences of three mitochondrial and four nuclear gene fragments in an extended sampling of Malagasy skinks, and microtomographic analyses of osteology of various burrowing taxa adapted to sand substrate. Based on our data we propose to (i) consider Sirenoscincus Sakata & Hikida, 2003, as junior synonym of Voeltzkowia Boettger, 1893; (ii) resurrect the genus name Grandidierina Mocquard, 1894, for four species previously included in Voeltzkowia; and (iii) consider Androngo Brygoo, 1982, as junior synonym of Pygomeles Grandidier, 1867. By supporting the clade consisting of the limbless Voeltzkowia mira and the forelimb-only taxa V. mobydick and V. yamagishii, our data indicate that full regression of limbs and eyes occurred in parallel twice in the genus Voeltzkowia (as hitherto defined) that we consider as a sand-swimming ecomorph: in the Voeltzkowia clade sensu stricto the regression first affected the hindlimbs and subsequently the forelimbs, whereas the Grandidierina clade first regressed the forelimbs and subsequently the hindlimbs following the pattern prevalent in squamates. Timetree reconstructions for the Malagasy Scincidae contain a substantial amount of uncertainty due to the absence of suitable primary fossil calibrations. However, our preliminary reconstructions suggest rapid limb regression in Malagasy scincids with an estimated maximal duration of 6 MYr for a complete regression in Paracontias, and 4 and 8 MYr respectively for complete regression of forelimbs in Grandidierina and hindlimbs in Voeltzkowia.
Invernizzi, M; Negrini, S; Carda, S; Lanzotti, L; Cisari, C; Baricich, A
2013-06-01
Upper limb paresis remains a relevant challenge in stroke rehabilitation. To evaluate if adding mirror therapy (MT) to conventional therapy (CT) can improve motor recovery of the upper limb in subacute stroke patients. Prospective, single-center, single-blind, randomised, controlled trial. Subacute stroke patients referred to a Physical and Rehabilitation Medicine Unit between October 2009 and August 2011. Twenty-six subacute stroke patients (time from stroke <4 weeks) with upper limb paresis (Motricity Index ≤ 77). Patients were randomly allocated to the MT (N.=13) or to the CT group (N.=13). Both followed a comprehensive rehabilitative treatment. In addition, MT Group had 30 minutes of MT while the CT group had 30 minutes of sham therapy. Action Research Arm Test (ARAT) was the primary outcome measures. Motricity Index (MI) and the Functional Independence Measure (FIM) were the secondary outcome measures. After one month of treatment patients of both groups showed statistically significant improvements in all the variables measured (P<0.05). Moreover patients of the MT group had greater improvements in the ARAT, MI and FIM values compared to CT group (P<0.01, Glass's Δ Effect Size: 1.18). No relevant adverse event was recorded during the study. MT is a promising and easy method to improve motor recovery of the upper limb in subacute stroke patients. While MT use has been advocated for acute patients with no or negligible motor function, it can be usefully extended to patients who show partial motor recovery. The easiness of implementation, the low cost and the acceptability makes this therapy an useful tool in stroke rehabilitation.
The use of bioimpedance analysis to evaluate lymphedema.
Warren, Anne G; Janz, Brian A; Slavin, Sumner A; Borud, Loren J
2007-05-01
Lymphedema, a chronic disfiguring condition resulting from lymphatic dysfunction or disruption, can be difficult to accurately diagnose and manage. Of particular challenge is identifying the presence of clinically significant limb swelling through simple and noninvasive methods. Many historical and currently used techniques for documenting differences in limb volume, including volume displacement and circumferential measurements, have proven difficult and unreliable. Bioimpedance spectroscopy analysis, a technology that uses resistance to electrical current in comparing the composition of fluid compartments within the body, has been considered as a cost-effective and reproducible alternative for evaluating patients with suspected lymphedema. All patients were recruited through the Beth Israel Deaconess Medical Center Lymphedema Clinic. A total of 15 patients (mean age: 55.2 years) with upper-extremity or lower-extremity lymphedema as documented by lymphoscintigraphy underwent bioimpedance spectroscopy analysis using an Impedimed SFB7 device. Seven healthy medical students and surgical residents (mean age: 26.9 years) were selected to serve as normal controls. All study participants underwent analysis of both limbs, which allowed participants to act as their own controls. The multifrequency bioimpedance device documented impedance values for each limb, with lower values correlating with higher levels of accumulated protein-rich edematous fluid. The average ratio of impedance to current flow of the affected limb to the unaffected limb in lymphedema patients was 0.9 (range: 0.67 to 1.01). In the control group, the average impedance ratio of the participant's dominant limb to their nondominant limb was 0.99 (range: 0.95 to 1.02) (P = 0.01). Bioimpedance spectroscopy can be used as a reliable and accurate tool for documenting the presence of lymphedema in patients with either upper- or lower-extremity swelling. Measurement with the device is quick and simple and results are reproducible among patients. Given significant limitations with other methods of evaluating lymphedema, the use of bioimpedance analysis may aid in the diagnosis of lymphedema and allow for tracking patients over time as they proceed with treatment of their disease.
Hellman, Randall B.; Chang, Eric; Tanner, Justin; Helms Tillery, Stephen I.; Santos, Veronica J.
2015-01-01
Many upper limb amputees experience an incessant, post-amputation “phantom limb pain” and report that their missing limbs feel paralyzed in an uncomfortable posture. One hypothesis is that efferent commands no longer generate expected afferent signals, such as proprioceptive feedback from changes in limb configuration, and that the mismatch of motor commands and visual feedback is interpreted as pain. Non-invasive therapeutic techniques for treating phantom limb pain, such as mirror visual feedback (MVF), rely on visualizations of postural changes. Advances in neural interfaces for artificial sensory feedback now make it possible to combine MVF with a high-tech “rubber hand” illusion, in which subjects develop a sense of embodiment with a fake hand when subjected to congruent visual and somatosensory feedback. We discuss clinical benefits that could arise from the confluence of known concepts such as MVF and the rubber hand illusion, and new technologies such as neural interfaces for sensory feedback and highly sensorized robot hand testbeds, such as the “BairClaw” presented here. Our multi-articulating, anthropomorphic robot testbed can be used to study proprioceptive and tactile sensory stimuli during physical finger–object interactions. Conceived for artificial grasp, manipulation, and haptic exploration, the BairClaw could also be used for future studies on the neurorehabilitation of somatosensory disorders due to upper limb impairment or loss. A remote actuation system enables the modular control of tendon-driven hands. The artificial proprioception system enables direct measurement of joint angles and tendon tensions while temperature, vibration, and skin deformation are provided by a multimodal tactile sensor. The provision of multimodal sensory feedback that is spatiotemporally consistent with commanded actions could lead to benefits such as reduced phantom limb pain, and increased prosthesis use due to improved functionality and reduced cognitive burden. PMID:25745391
Hellman, Randall B; Chang, Eric; Tanner, Justin; Helms Tillery, Stephen I; Santos, Veronica J
2015-01-01
Many upper limb amputees experience an incessant, post-amputation "phantom limb pain" and report that their missing limbs feel paralyzed in an uncomfortable posture. One hypothesis is that efferent commands no longer generate expected afferent signals, such as proprioceptive feedback from changes in limb configuration, and that the mismatch of motor commands and visual feedback is interpreted as pain. Non-invasive therapeutic techniques for treating phantom limb pain, such as mirror visual feedback (MVF), rely on visualizations of postural changes. Advances in neural interfaces for artificial sensory feedback now make it possible to combine MVF with a high-tech "rubber hand" illusion, in which subjects develop a sense of embodiment with a fake hand when subjected to congruent visual and somatosensory feedback. We discuss clinical benefits that could arise from the confluence of known concepts such as MVF and the rubber hand illusion, and new technologies such as neural interfaces for sensory feedback and highly sensorized robot hand testbeds, such as the "BairClaw" presented here. Our multi-articulating, anthropomorphic robot testbed can be used to study proprioceptive and tactile sensory stimuli during physical finger-object interactions. Conceived for artificial grasp, manipulation, and haptic exploration, the BairClaw could also be used for future studies on the neurorehabilitation of somatosensory disorders due to upper limb impairment or loss. A remote actuation system enables the modular control of tendon-driven hands. The artificial proprioception system enables direct measurement of joint angles and tendon tensions while temperature, vibration, and skin deformation are provided by a multimodal tactile sensor. The provision of multimodal sensory feedback that is spatiotemporally consistent with commanded actions could lead to benefits such as reduced phantom limb pain, and increased prosthesis use due to improved functionality and reduced cognitive burden.
Total Solar Eclipse of 2006 March 29
NASA Technical Reports Server (NTRS)
Espenak, F.; Anderson, J.
2004-01-01
On 2006 March 29, a total eclipse of the Sun will be visible from within a narrow corridor which traverses half the Earth. The path of the Moon's umbral shadow begins in Brazil and extends across the Atlantic, northern Africa, and central Asia where it ends at sunset in western Mongolia. A partial eclipse will be seen within the much broader path of the Moon's penumbral shadow, which includes the northern two thirds of Africa, Europe, and central Asia.Detailed predictions for this event are presented and include besselian elements, geographic coordinates of the path of totality, physical ephemeris of the umbra, topocentric limb profile corrections, local circumstances for approximately 350 cities, maps of the eclipse path, weather prospects, the lunar limb profile, and the sky during totality. Information on safe eclipse viewing and eclipse photography is included.
Skeletal Structural Consequences of Reduced Gravity Environments
NASA Technical Reports Server (NTRS)
Ruff, Christropher B.
1999-01-01
The overall goal of this project is to provide structurally meaningful data on bone loss after exposure to reduced gravity environments so that more precise estimates of fracture risk and the effectiveness of countermeasures in reducing fracture risk can be developed. The project has three major components: (1) measure structural changes in the limb bones of rats subjected to complete and partial nonweightbearing, with and without treatment with ibandronate and periodic full weightbearing; (2) measure structural changes in the limb bones of human bedrest subjects, with and without treatment with alendronate and resistive exercise, and Russian cosmonauts flying on the Mir Space Station; and (3) validate and extend the 2-dimensional structural analyses currently possible in the second project component (bedrest and Mir subjects) using 3-dimensional finite element modeling techniques, and determine actual fracture-producing loads on earth and in space.
Modification of a Limbed Robot to Favor Climbing
NASA Technical Reports Server (NTRS)
Okon, Avi; Kennedy, Brett; Garrett, Michael; Magnone, Lee
2006-01-01
The figure shows the LEMUR IIb, which is a modified version of the LEMUR II the second generation of the Limbed Excursion Mechanical Utility Robot (LEMUR). Except as described below, the LEMUR IIb hardware is mostly the same as that of the LEMUR II. The IIb and II versions differ in their kinematic configurations and characteristics associated with their kinematic configurations. The differences are such that relative to the LEMUR II, the LEMUR IIb is simpler and is better suited to climbing on inclined surfaces. The first-generation LEMUR, now denoted the LEMUR I, was described in Six-Legged Experimental Robot (NPO-20897), NASA Tech Briefs, Vol. 25, No. 12 (December 2001), page 58. The LEMUR II was described in Second-Generation Six-Limbed Experimental Robot (NPO-35140) NASA Tech Briefs, Vol. 28, No. 11 (November 2004), page 55. To recapitulate: the LEMUR I and LEMUR II were six-legged or sixlimbed robots for demonstrating robotic capabilities for assembly, maintenance, and inspection. They were designed to be capable of walking autonomously along a truss structure toward a mechanical assembly at a prescribed location. They were equipped with stereoscopic video cameras and image-data-processing circuitry for navigation and mechanical operations. They were also equipped with wireless modems, through which they could be commanded remotely. Upon arrival at a mechanical assembly, the LEMUR I would perform simple mechanical operations by use of one or both of its front legs (or in the case of the LEMUR II, any of its limbs could be used to perform mechanical operations). Either LEMUR could also transmit images to a host computer. The differences between the LEMUR IIb and the LEMUR II are the following: Whereas the LEMUR II had six limbs, the LEMUR IIb has four limbs. This change has reduced both the complexity and mass of the legs and of the overall robot. Whereas each limb of the LEMUR II had four degrees of freedom (DOFs), each limb of the LEMUR IIb has three DOFs. This change has also reduced both complexity and mass. Notwithstanding the decrease in the number of DOFs, the three remaining DOFs are configured to provide greater dexterity for motion along a surface. To extend reach, the limbs of the LEMUR IIb are 25 percent longer than those of the LEMUR II. Additional benefits stemming from the modifications are that the robot body supported by the limbs is now less massive and its center of gravity is now closer to the surface along which the robot is to move. These benefits have been obtained without sacrificing load-carrying capacity. Hence, overall, the LEMUR IIb is a more adept climber.
The embodiment of assistive devices-from wheelchair to exoskeleton
NASA Astrophysics Data System (ADS)
Pazzaglia, Mariella; Molinari, Marco
2016-03-01
Spinal cord injuries (SCIs) place a heavy burden on the healthcare system and have a high personal impact and marked socio-economic consequences. Clinically, no absolute cure for these conditions exists. However, in recent years, there has been an increased focus on new robotic technologies that can change the frame we think about the prognosis for recovery and for treating some functions of the body affected after SCIs. This review has two goals. The first is to assess the possibility of the embodiment of functional assistive tools after traumatic disruption of the neural pathways between the brain and the body. To this end, we will examine how altered sensorimotor information modulates the sense of the body in SCI. The second goal is to map the phenomenological experience of using external tools that typically extend the potential of the body physically impaired by SCI. More specifically, we will focus on the difference between the perception of one's physically augmented and non-augmented affected body based on observable and measurable behaviors. We discuss potential clinical benefits of enhanced embodiment of the external objects by way of multisensory interventions. This review argues that the future evolution of human robotic technologies will require adopting an embodied approach, taking advantage of brain plasticity to allow bionic limbs to be mapped within the neural circuits of physically impaired individuals.
A brain-controlled lower-limb exoskeleton for human gait training.
Liu, Dong; Chen, Weihai; Pei, Zhongcai; Wang, Jianhua
2017-10-01
Brain-computer interfaces have been a novel approach to translate human intentions into movement commands in robotic systems. This paper describes an electroencephalogram-based brain-controlled lower-limb exoskeleton for gait training, as a proof of concept towards rehabilitation with human-in-the-loop. Instead of using conventional single electroencephalography correlates, e.g., evoked P300 or spontaneous motor imagery, we propose a novel framework integrated two asynchronous signal modalities, i.e., sensorimotor rhythms (SMRs) and movement-related cortical potentials (MRCPs). We executed experiments in a biologically inspired and customized lower-limb exoskeleton where subjects (N = 6) actively controlled the robot using their brain signals. Each subject performed three consecutive sessions composed of offline training, online visual feedback testing, and online robot-control recordings. Post hoc evaluations were conducted including mental workload assessment, feature analysis, and statistics test. An average robot-control accuracy of 80.16% ± 5.44% was obtained with the SMR-based method, while estimation using the MRCP-based method yielded an average performance of 68.62% ± 8.55%. The experimental results showed the feasibility of the proposed framework with all subjects successfully controlled the exoskeleton. The current paradigm could be further extended to paraplegic patients in clinical trials.
A brain-controlled lower-limb exoskeleton for human gait training
NASA Astrophysics Data System (ADS)
Liu, Dong; Chen, Weihai; Pei, Zhongcai; Wang, Jianhua
2017-10-01
Brain-computer interfaces have been a novel approach to translate human intentions into movement commands in robotic systems. This paper describes an electroencephalogram-based brain-controlled lower-limb exoskeleton for gait training, as a proof of concept towards rehabilitation with human-in-the-loop. Instead of using conventional single electroencephalography correlates, e.g., evoked P300 or spontaneous motor imagery, we propose a novel framework integrated two asynchronous signal modalities, i.e., sensorimotor rhythms (SMRs) and movement-related cortical potentials (MRCPs). We executed experiments in a biologically inspired and customized lower-limb exoskeleton where subjects (N = 6) actively controlled the robot using their brain signals. Each subject performed three consecutive sessions composed of offline training, online visual feedback testing, and online robot-control recordings. Post hoc evaluations were conducted including mental workload assessment, feature analysis, and statistics test. An average robot-control accuracy of 80.16% ± 5.44% was obtained with the SMR-based method, while estimation using the MRCP-based method yielded an average performance of 68.62% ± 8.55%. The experimental results showed the feasibility of the proposed framework with all subjects successfully controlled the exoskeleton. The current paradigm could be further extended to paraplegic patients in clinical trials.
The comparative anatomy of the forelimb veins of primates.
Thiranagama, R; Chamberlain, A T; Wood, B A
1989-01-01
One hundred and thirteen forelimbs taken from 62 individuals belonging to 17 primate genera were dissected to reveal the entire course of the superficial venous system. The course of the deep venous system was also documented in at least one forelimb of each primate genus, and the number and location of perforating veins was recorded in 18 human and 45 non-human primate limbs. In Pan, Gorilla and in about 25% of human specimens the lateral superficial vein was confined to the forearm, while in all other primates, and in the majority of humans, this vein extended from the carpus to the clavicular region. Only Pongo and humans exhibited a second main superficial vein on the medial side of the forearm. In all primates the deep veins of the forelimb usually accompanied the arteries. Thus variation in the deep venous system reflected the different arterial patterns exhibited by these primates. The number of perforating veins in the forelimb was related to the length of the limb. Primate genera with longer forelimbs had more perforators, though not as many as would be expected if the number of perforators scaled linearly with limb length. PMID:2514175
EEG controlled neuromuscular electrical stimulation of the upper limb for stroke patients
NASA Astrophysics Data System (ADS)
Tan, Hock Guan; Shee, Cheng Yap; Kong, Keng He; Guan, Cuntai; Ang, Wei Tech
2011-03-01
This paper describes the Brain Computer Interface (BCI) system and the experiments to allow post-acute (<3 months) stroke patients to use electroencephalogram (EEG) to trigger neuromuscular electrical stimulation (NMES)-assisted extension of the wrist/fingers, which are essential pre-requisites for useful hand function. EEG was recorded while subjects performed motor imagery of their paretic limb, and then analyzed to determine the optimal frequency range within the mu-rhythm, with the greatest attenuation. Aided by visual feedback, subjects then trained to regulate their mu-rhythm EEG to operate the BCI to trigger NMES of the wrist/finger. 6 post-acute stroke patients successfully completed the training, with 4 able to learn to control and use the BCI to initiate NMES. This result is consistent with the reported BCI literacy rate of healthy subjects. Thereafter, without the loss of generality, the controller of the NMES is developed and is based on a model of the upper limb muscle (biceps/triceps) groups to determine the intensity of NMES required to flex or extend the forearm by a specific angle. The muscle model is based on a phenomenological approach, with parameters that are easily measured and conveniently implemented.
ERIC Educational Resources Information Center
Chang, Chi-Cheng; Yan, Chi-Fang; Tseng, Ju-Shih
2012-01-01
Since convenience is one of the features for mobile learning, does it affect attitude and intention of using mobile technology? The technology acceptance model (TAM), proposed by David (1989), was extended with perceived convenience in the present study. With regard to English language mobile learning, the variables in the extended TAM and its…
Maestri, Michelangelo; Fulda, Stephany; Ferini-Strambi, Luigi; Zucconi, Marco; Marelli, Sara; Staedler, Claudio; Bassetti, Claudio L; Manconi, Mauro
2014-05-01
Dopamine agonists (DAs) represent the first-line treatment in restless legs syndrome (RLS); however, in the long term, a substantial proportion of patients will develop augmentation, which is a severe drug-related exacerbation of symptoms and the main reason for late DA withdrawal. Polysomnographic features and mechanisms underlining augmentation are unknown. No practice guidelines for management of augmentation are available. A clinical case series of 24 consecutive outpatients affected by RLS with clinically significant augmentation during treatment with immediate-release DA was performed. All patients underwent a full-night polysomnographic recording during augmentation. A switchover from immediate-release DAs (l-dopa, pramipexole, ropinirole, rotigotine) to the long-acting, extended-release formula of pramipexole was performed. Fifty percent of patients presented more than 15 periodic limb movements per hour of sleep during augmentation, showing longer sleep latency and shorter total sleep time than subjects without periodic limb movements. In all patients, resolution of augmentation was observed within two to four weeks during which immediate-release dopamine agonists could be completely withdrawn. Treatment efficacy of extended-release pramipexole has persisted, thus far, over a mean follow-up interval of 13 months. Pramipexole extended release could be an easy, safe, and fast pharmacological option to treat augmentation in patients with restless legs syndrome. As such it warrants further prospective and controlled investigations. This observation supports the hypothesis that the duration of action of the drug plays a key role in the mechanism of augmentation. Copyright © 2014 Elsevier B.V. All rights reserved.
Using commercial video games for upper limb stroke rehabilitation: is this the way of the future?
Pietrzak, Eva; Cotea, Cristina; Pullman, Stephen
2014-01-01
The increasing number of people living with poststroke sequelae has stimulated the search for novel ways of providing poststroke rehabilitation without putting additional stress on overburdened health care systems. One of them is the use of commercially available technology and off-the-shelf video games for hemiparetic upper limb rehabilitation. The MEDLINE, EMBASE, and Cochrane Library databases were searched using key word synonyms for stroke, upper limb, and video games. Included studies investigated upper limb stroke rehabilitation using commercially available consoles and video games, reported outcomes that included measures of upper limb functionality, and were published in a peer-reviewed journal written in English. Thirteen studies were identified - 6 published as full articles and 7 as abstracts. Studies were generally small and only 3 were randomized. The gaming systems investigated were the Nintendo Wii (n = 10), EyeToy PlayStation (n = 2), and CyWee Z (n = 1). The Nintendo Wii appears to provide the greatest benefits to patients, with improvements seen in upper extremity function measures such as joint range of motion, hand motor function, grip strength, and dexterity. Three studies indicate that video therapy appears to be safe and that long-term improvements continue at follow-up. At present, the evidence that the use of commercial video games in rehabilitation improves upper limb functionality after stroke is very limited. However, this approach has the potential to provide easily available and affordable stroke rehabilitation therapy in settings where access to therapy is limited by geographical or financial constraints.
Nayak, Chitresh; Singh, Amit; Chaudhary, Himanshu; Unune, Deepak Rajendra
2017-10-23
Technological advances in prosthetics have attracted the curiosity of researchers in monitoring design and developments of the sockets to sustain maximum pressure without any soft tissue damage, skin breakdown, and painful sores. Numerous studies have been reported in the area of pressure measurement at the limb/socket interface, though, the relation between amputee's physiological parameters and the pressure developed at the limb/socket interface is still not studied. Therefore, the purpose of this work is to investigate the effects of patient-specific physiological parameters viz. height, weight, and stump length on the pressure development at the transtibial prosthetic limb/socket interface. Initially, the pressure values at the limb/socket interface were clinically measured during stance and walking conditions for different patients using strain gauges placed at critical locations of the stump. The measured maximum pressure data related to patient's physiological parameters was used to develop an artificial neural network (ANN) model. The effects of physiological parameters on the pressure development at the limb/socket interface were examined using the ANN model. The analyzed results indicated that the weight and stump length significantly affects the maximum pressure values. The outcomes of this work could be an important platform for the design and development of patient-specific prosthetic socket which can endure the maximum pressure conditions at stance and ambulation conditions.
Upper extremity transplantation: current concepts and challenges in an emerging field.
Elliott, River M; Tintle, Scott M; Levin, L Scott
2014-03-01
Loss of an isolated upper limb is an emotionally and physically devastating event that results in significant impairment. Patients who lose both upper extremities experience profound disability that affects nearly every aspect of their lives. While prosthetics and surgery can eventually provide the single limb amputee with a suitable assisting hand, limited utility, minimal haptic feedback, weight, and discomfort are persistent problems with these techniques that contribute to high rates of prosthetic rejection. Moreover, despite ongoing advances in prosthetic technology, bilateral amputees continue to experience high levels of dependency, disability, and distress. Hand and upper extremity transplantation holds several advantages over prosthetic rehabilitation. The missing limb is replaced with one of similar skin color and size. Sensibility, voluntary motor control, and proprioception are restored to a greater degree, and afford better dexterity and function than prosthetics. The main shortcomings of transplantation include the hazards of immunosuppression, the complications of rejection and its treatment, and high cost. Hand and upper limb transplantation represents the most commonly performed surgery in the growing field of Vascularized Composite Allotransplantation (VCA). As upper limb transplantation and VCA have become more widespread, several important challenges and controversies have emerged. These include: refining indications for transplantation, optimizing immunosuppression, establishing reliable criteria for monitoring, diagnosing, and treating rejection, and standardizing outcome measures. This article will summarize the historical background of hand transplantation and review the current literature and concepts surrounding it.
Iwamoto, Masahiro; Tamamura, Yoshihiro; Koyama, Eiki; Komori, Toshihisa; Takeshita, Nobuo; Williams, Julie A; Nakamura, Takashi; Enomoto-Iwamoto, Motomi; Pacifici, Maurizio
2007-05-01
Articular cartilage and synovial joints are critical for skeletal function, but the mechanisms regulating their development are largely unknown. In previous studies we found that the ets transcription factor ERG and its alternatively-spliced variant C-1-1 have roles in joint formation in chick. Here, we extended our studies to mouse. We found that ERG is also expressed in developing mouse limb joints. To test regulation of ERG expression, beads coated with the joint master regulator protein GDF-5 were implanted close to incipient joints in mouse limb explants; this led to rapid and strong ectopic ERG expression. We cloned and characterized several mammalian ERG variants and expressed a human C-1-1 counterpart (hERG3Delta81) throughout the cartilaginous skeleton of transgenic mice, using Col2a1 gene promoter/enhancer sequences. The skeletal phenotype was severe and neonatal lethal, and the transgenic mice were smaller than wild type littermates and their skeletons were largely cartilaginous. Limb long bone anlagen were entirely composed of chondrocytes actively expressing collagen IX and aggrecan as well as articular markers such as tenascin-C. Typical growth plates were absent and there was very low expression of maturation and hypertrophy markers, including Indian hedgehog, collagen X and MMP-13. The results suggest that ERG is part of molecular mechanisms leading chondrocytes into a permanent developmental path and become joint forming cells, and may do so by acting downstream of GDF-5.
Development of a bone-fixation prosthetic attachment. [with quick-disconnect coupling
NASA Technical Reports Server (NTRS)
Owens, L. J.
1975-01-01
An artificial limb attached directly to the bone by a quick-disconnect coupling was tested in-place at a California medical rehabilitation center. Its design concept and development, made possible by multiple spinoffs of aerospace technology, are discussed.
2012-01-01
The control of robotic prostheses based on pattern recognition algorithms is a widely studied subject that has shown promising results in acute experiments. The long-term implementation of this technology, however, has not yet been achieved due to practical issues that can be mainly attributed to the use of surface electrodes and their highly environmental dependency. This paper describes several implantable electrodes and discusses them as a solution for the natural control of artificial limbs. In this context “natural” is defined as producing control over limb movement analogous to that of an intact physiological system. This includes coordinated and simultaneous movements of different degrees of freedom. It also implies that the input signals must come from nerves or muscles that were originally meant to produce the intended movement and that feedback is perceived as originating in the missing limb without requiring burdensome levels of concentration. After scrutinizing different electrode designs and their clinical implementation, we concluded that the epimysial and cuff electrodes are currently promising candidates to achieving a long-term stable and natural control of robotic prosthetics, provided that communication from the electrodes to the outside of the body is guaranteed. PMID:22715940
Critical appraisal of surgical revascularization for critical limb ischemia.
Conte, Michael S
2013-02-01
Peripheral artery disease is growing in global prevalence and is estimated to afflict between 8 and 12 million Americans. Its most severe form, critical limb ischemia (CLI), is associated with high rates of limb loss, morbidity, and mortality. Revascularization is the cornerstone of limb preservation in CLI, and has traditionally been accomplished with open surgical bypass. Advances in catheter-based technologies, coupled with their broad dissemination among specialists, have led to major shifts in practice patterns in CLI. There is scant high-quality evidence to guide surgical decision making in this arena, and market forces have exerted profound influences. Despite this, available data suggest that the expected outcomes for both endovascular and open surgery in CLI are strongly dependent on definable patient factors such as anatomic distribution of disease, vein quality, and comorbidities. Optimal patient selection is paramount for maximizing benefit with each technique. This review summarizes some of the existing data and suggests a selective approach to revascularization in CLI, which continues to rely on vein bypass surgery as a primary option in appropriately selected patients. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Research on Safety and Compliance of a New Lower Limb Rehabilitation Robot
Feng, Yongfei; Wang, Hongbo; Yan, Hao; Wang, Xincheng; Jin, Zhennan; Vladareanu, Luige
2017-01-01
The lower limb rehabilitation robot is an application of robotic technology for stroke people with lower limb disabilities. A new applicable and effective sitting/lying lower limb rehabilitation robot (LLR-Ro) is proposed, which has the mechanical limit protection, the electrical limit protection, and the software protection to prevent the patient from the secondary damage. Meanwhile, as a new type of the rehabilitation robots, its hip joint rotation ranges are different in the patient sitting training posture and lying training posture. The mechanical leg of the robot has a variable workspace to work in both training postures. So, if the traditional mechanical limit and the electrical limit cannot be used in the hip joint mechanism design, a follow-up limit is first proposed to improve the compatibility of human-machine motion. Besides, to eliminate the accident interaction force between the patient and LLR-Ro in the process of the passive training, an amendment impedance control strategy based on the position control is proposed to improve the compliance of the LLR-Ro. A simulation experiment and an experiment with a participant show that the passive training of LLR-Ro has compliance. © 2017 Yongfei Feng et al.
Research on Safety and Compliance of a New Lower Limb Rehabilitation Robot
Yan, Hao; Wang, Xincheng; Jin, Zhennan; Vladareanu, Luige
2017-01-01
The lower limb rehabilitation robot is an application of robotic technology for stroke people with lower limb disabilities. A new applicable and effective sitting/lying lower limb rehabilitation robot (LLR-Ro) is proposed, which has the mechanical limit protection, the electrical limit protection, and the software protection to prevent the patient from the secondary damage. Meanwhile, as a new type of the rehabilitation robots, its hip joint rotation ranges are different in the patient sitting training posture and lying training posture. The mechanical leg of the robot has a variable workspace to work in both training postures. So, if the traditional mechanical limit and the electrical limit cannot be used in the hip joint mechanism design, a follow-up limit is first proposed to improve the compatibility of human-machine motion. Besides, to eliminate the accident interaction force between the patient and LLR-Ro in the process of the passive training, an amendment impedance control strategy based on the position control is proposed to improve the compliance of the LLR-Ro. A simulation experiment and an experiment with a participant show that the passive training of LLR-Ro has compliance. PMID:29065571
Comparison of mechanical energy profiles of passive and active below-knee prostheses: a case study.
Takahashi, Kota Z; Horne, John R; Stanhope, Steven J
2015-04-01
With the recent technological advancements of prosthetic lower limbs, there is currently a great desire to objectively evaluate existing prostheses. Using a novel biomechanical analysis, the purpose of this case study was to compare the mechanical energy profiles of anatomical and two disparate prostheses: a passive prosthesis and an active prosthesis. An individual with a transtibial amputation who customarily wears a passive prosthesis (Elation, Össur) and an active prosthesis (BiOM, iWalk, Inc.) and 11 healthy subjects participated in an instrumented gait analysis. The total mechanical power and work of below-knee structures during stance were quantified using a unified deformable segment power analysis. Active prosthesis generated greater peak power and total positive work than passive prosthesis and healthy anatomical limbs. The case study will enhance future efforts to objectively evaluate prosthetic functions during gait in individuals with transtibial amputations. A prosthetic limb should closely replicate the mechanical energy profiles of anatomical limbs. The unified deformable (UD) analysis may be valuable to facilitate future clinical prescription and guide fine adjustments of prosthetic componentry to optimize gait outcomes. © The International Society for Prosthetics and Orthotics 2014.
Schweitzer, Wolf; Thali, Michael J; Egger, David
2018-01-03
Prosthetic arm research predominantly focuses on "bionic" but not body-powered arms. However, any research orientation along user needs requires sufficiently precise workplace specifications and sufficiently hard testing. Forensic medicine is a demanding environment, also physically, also for non-disabled people, on several dimensions (e.g., distances, weights, size, temperature, time). As unilateral below elbow amputee user, the first author is in a unique position to provide direct comparison of a "bionic" myoelectric iLimb Revolution (Touch Bionics) and a customized body-powered arm which contains a number of new developments initiated or developed by the user: (1) quick lock steel wrist unit; (2) cable mount modification; (3) cast shape modeled shoulder anchor; (4) suspension with a soft double layer liner (Ohio Willowwood) and tube gauze (Molnlycke) combination. The iLimb is mounted on an epoxy socket; a lanyard fixed liner (Ohio Willowwood) contains magnetic electrodes (Liberating Technologies). An on the job usage of five years was supplemented with dedicated and focused intensive two-week use tests at work for both systems. The side-by-side comparison showed that the customized body-powered arm provides reliable, comfortable, effective, powerful as well as subtle service with minimal maintenance; most notably, grip reliability, grip force regulation, grip performance, center of balance, component wear down, sweat/temperature independence and skin state are good whereas the iLimb system exhibited a number of relevant serious constraints. Research and development of functional prostheses may want to focus on body-powered technology as it already performs on manually demanding and heavy jobs whereas eliminating myoelectric technology's constraints seems out of reach. Relevant testing could be developed to help expediting this. This is relevant as Swiss disability insurance specifically supports prostheses that enable actual work integration. Myoelectric and cosmetic arm improvement may benefit from a less forgiving focus on perfecting anthropomorphic appearance.
Recovery of lower limb function following 6 weeks of non-weight bearing
NASA Astrophysics Data System (ADS)
MacIntyre, Donna L.; Eng, Janice J.; Allen, Trevor J.
2005-05-01
Skeletal muscle weakness and atrophy occur following an extended period of decreased use, including space flight and limb unloading. It is also likely that affected muscles will be susceptible to a re-loading injury when they begin return to earth or weight bearing. However, there is a paucity of literature evaluating the response of human unloaded muscle to exercise and return to activity. The purpose of this pilot study was to evaluate the soreness, function and strength response of muscle to re-loading in seven patients who were non-weight bearing for 6 weeks, compared to five healthy subjects. Function improved significantly over time for the patients but was still less than the healthy subjects over 12 weeks of physiotherapy. Concentric quadriceps muscle strength increased significantly over time for the patients. There was considerable variability in the patients' reports of muscle soreness but there were no significant changes over time or between groups.
Solar Spicules Near and at the Limb, Observed from Hinode
NASA Technical Reports Server (NTRS)
Sterling, Alphonse C.; Moore, Ronald
2009-01-01
Solar spicules appear as narrow jets emanating from the chromosphere and extending into the corona. They have been observed for over a hundred years, mainly in chromospheric spectral lines such as H-alpha. Because they are at the limit of visibility of ground-based instruments, their nature has long been a puzzle (Beckers 1968, 1972; Sterling 2000). In recent years however, vast progress has been made in understanding them both theoretically and observationally, as spicule studies have undergone a revolution because of the superior resolution and time cadence of ground-based and space-based instruments (e.g., DePontieu et al. 2004). Even more rapid progress is currently underway, due to the Solar Optical Telescope (SOT) instrument on the Hinode spacecraft (e.g., De Pontieu et al. 2007a, 2007b). Here we present observations of spicules from Hinode SOT, as seen near the limb with the Ca II filtergraph.
An extended superhot solar flare X-ray source
NASA Technical Reports Server (NTRS)
Hudson, H. S.; Ohki, K. I.; Tsuneta, S.
1985-01-01
A superhot hard X-ray source in a solar flare occulted by the solar limb was identified. Its hard X-ray image was found to show great horizontal extent but little vertical extent. An H alpha brightening at the same limb position about an hour later suggests a multi-component loop prominence system, so that it appears that a superhot source can evolve in the same manner as a normal solar soft X-ray source. The assignment of plausiable values to physical parameters in the source suggests (from the simplest form of classical thermal-conduction theory) that either new physics will be required to suppress conduction, or else that gradual energy release well after the impulsive phase of the flare must occur. In this respect too, the superhot source appears to resemble ordinary soft X-ray sources, except of course that its temperature is higher.
The subtropical mesospheric jet observed by the Nimbus 7 Limb Infrared Monitor of the Stratosphere
NASA Technical Reports Server (NTRS)
Dunkerton, T. J.; Delisi, D. P.
1985-01-01
Nimbus 7 Limb Infrared Monitor of the Stratosphere observations of wave-mean flow interactions in the winter 1978-1979 middle atmosphere are surveyed, extending up to 0.05 mbar. These observations describe the evolution of the subtropical mesospheric jet and its polar mixed layer. Quasi-steady mean wind patterns are disrupted by three transitions in this winter: one primarily affecting the mesosphere (December 15, 1978), a minor warming affecting both regions (January 26-February 8, 1979), and a major warming largely confined to the stratosphere (February 22, 1979). The zonally averaged flow is barotropically unstable in the wings of the subtropical mesospheric jet. All the major decelerations of the mean flow are correlated with D(F), the body force per unit mass directly attributable to planetary Rossby waves, indicating that these waves make a significant contribution to the momentum budget in the lower half of the mesosphere.
Jain, Ankur
2014-01-01
We report a case of a 60-year-old lady who presented with bilateral lower limb swelling and a thyroid swelling with clinical features consistent with thyrotoxicosis. Investigations revealed the presence of a thrombus in bilateral external, internal iliac veins, and inferior vena cava extending up to its infrahepatic part. Hormone profile and radioiodine uptake scan confirmed the diagnosis of Graves’ disease. Further workup revealed the presence of antiphospholipid antibodies (confirmed after a repeat test at 12 weeks). The patient was treated with antithyroid drugs and anticoagulants. The patient improved with normalization of thyroid function and partial recanalization of the infrahepatic part of inferior vena cava. Hyperthyroidism has been implicated as a potential hypercoagulable state; however, the association of Graves’ disease with antiphospholipid antibody syndrome is limited to isolated case reports. This case highlights a new mechanism underlying hypercoagulability associated with Graves’ disease. PMID:24812529
Su, Hui-Yi; Wu, Yung-Tsan; Liu, Ming-Ying; Lin, Yu-Chun; Chu, Heng-Yi; Chang, Shin-Tsu
2013-01-01
We present the first case of concomitant intramedullary traumatic neuroma and spinal cord herniation. A 57-year-old woman injured her cervical spine with subluxation and cord compression at the C5-C6 level. After the operation, the patient received intensive rehabilitation for one year with well response. Unfortunately, she experienced weakness and progressive numbness extending to all the limbs later. Cervical magnetic resonance imaging revealed spinal cord herniation at the C5-C6 level and pathology proved intramedullary traumatic neuroma. After the second operation, the paresthesia over the trunk and limbs persisted, and the patient was nearly totally assisted in her activities of daily living. The intramedullary traumatic neuroma and spinal cord herniation are rare causes in patients with spinal cord dysfunction. The case presented here indicates the possibility of the coexisting conditions leading to progressive neurologic deficits in patients with old spinal cord injury.
FootFall: A Ground Based Operations Toolset Enabling Walking for the ATHLETE Rover
NASA Technical Reports Server (NTRS)
SunSpiral, Vytas; Chavez-Clemente, Daniel; Broxton, Michael; Keely, Leslie; Mihelich, Patrick; Mittman, David; Collins, Curtis
2008-01-01
The ATHLETE (All-Terrain Hex-Limbed Extra-Terrestrial Explorer) vehicle consists of six identical, six degree of freedom limbs. FootFall is a ground tool for ATHLETE intended to provide an operator with integrated situational awareness, terrain reconstruction, stability and safety analysis, motion planning, and decision support capabilities to enable the efficient generation of flight software command sequences for walking. FootFall has been under development at NASA Ames for the last year, and having accomplished the initial integration, it is being used to generate command sequences for single footfalls. In this paper, the architecture of FootFall in its current state will be presented, results from the recent Human Robotic Systems Project?s Integrated Field Test (Moses Lake, Washington, June, 2008) will be discussed, and future plans for extending the capabilities of FootFall to enable ATHLETE to walk across a boulder field in real time will be described.
Biomechanical design of escalading lower limb exoskeleton with novel linkage joints.
Zhang, Guoan; Liu, Gangfeng; Ma, Sun; Wang, Tianshuo; Zhao, Jie; Zhu, Yanhe
2017-07-20
In this paper, an obstacle-surmounting-enabled lower limb exoskeleton with novel linkage joints that perfectly mimicked human motions was proposed. Currently, most lower exoskeletons that use linear actuators have a direct connection between the wearer and the controlled part. Compared to the existing joints, the novel linkage joint not only fitted better into compact chasis, but also provided greater torque when the joint was at a large bend angle. As a result, it extended the angle range of joint peak torque output. With any given power, torque was prioritized over rotational speed, because instead of rotational speed, sufficiency of torque is the premise for most joint actions. With insufficient torque, the exoskeleton will be a burden instead of enhancement to its wearer. With optimized distribution of torque among the joints, the novel linkage method may contribute to easier exoskeleton movements.
Deer, Timothy; Pope, Jason; Hayek, Salim; Narouze, Samer; Patil, Parag; Foreman, Robert; Sharan, Ashwini; Levy, Robert
2014-10-01
The use of spinal cord stimulation (SCS) is well established in the treatment of neuropathic pain. This procedure has been approved in the United States for neuropathic pain of the trunk and limbs from various conditions. International use is variable based on governmental policy. Most studies showing efficacy have focused on pain primarily in the limbs for such conditions as complex regional pain syndrome (CRPS), sciatica, radiculitis, ischemic limb pain, and peripheral neuropathy. Data on success in neuropathic pain of the trunk and particularly of the axial back are limited. New understanding about the targets of neuromodulation and their treatment with novel neurostimulation approaches has led to a new dawn of enthusiasm for spinal cord stimulation for axial low back pain. The authors review mechanisms, current and future targets, techniques, and their outcomes for treating axial back pain with neurostimulation. The paper discusses many newer methods and targets that may substantially improve results for the treatment of this patient group. The continuing evolution of technology and new data may well change these recommendations over time and regular updates of this manuscript will be critical moving forward. Improved technology and a better understanding of the goals of stimulation have led to a new ability to stimulate the axial low back and increase the effectiveness of these therapies to reduce pain. New paddle lead constructs, percutaneous paddle lead introduction, and other new technologies have led to an increased number of potential candidates for spinal cord stimulation. Optimizing the application of neurostimulation for chronic axial back pain will depend upon answering questions relating to patient selection, implantation technique, and stimulation parameters. © 2014 International Neuromodulation Society.
Can the recovery of lower limb fractures be achieved by use of 3D printing mirror model?
Zhang, Wenxi; Ji, Yueping; Wang, Xinming; Liu, Jie; Li, Dong
2017-11-01
The mirror imaging 3D printing model can be used a as a reference for anatomical reduction in unilateral lower limb fractures. However, the premise of using mirror technology is that the bilateral lower limb bones are similar enough. Because one side had a fracture, it was impossible to compare this directly to the other side. Usually, surgeons think that the bilateral bones are symmetrical and use mirror technology without judging their symmetry. In patients with a unilateral lower limb bone fracture, we measured the long axis and short axis of the three selected transverse sections of the bilateral long bone for comparison to judge the symmetry of the bilateral long bones on CT images. Then, we printed a life-size normal mirror image of the long bone that is similar to the affected side. The model was used as a reference for the anatomical reduction of fractures and preoperative practice. Seventy-eight patients with lower limb bone fracture were included in this study. 24 groups of data were generated according to the same level and same axis. There were significant differences between the short axis of the left and right femoral condyle 5cm from the intercondylar keel (p=0.011), and the short axis of the distal tibia 15cm from the ankle dome (p=0.026). There was no significant difference between the left and right sides in the other 22 groups. Of all of the patients in our research, 3 patients decided to forego the surgical treatment and the operation was performed on the model instead, and the lengths of 2 patients showed deviation in actual operations, preventing anatomical reduction. The remaining 73 patients used the pre-bended plates and screws from preoperative practice in the actual operations, and postoperative X-ray examinations showed that the length of the deviation was within the permissible range. The "Comparison of long axis and short axis of three equidistant transverse sections" method makes it easy to judge the symmetry of the bilateral long bones, and prevents the blindness of preoperative planning using the contralateral mirror model directly. Copyright © 2017 Elsevier Ltd. All rights reserved.
Seeking: Accurate Measurement Techniques for Deep-Bone Density and Structure
NASA Technical Reports Server (NTRS)
Sibonga, Jean
2009-01-01
We are seeking a clinically-useful technology with enough sensitivity to assess the microstructure of "spongy" bone that is found in the marrow cavities of whole bones. However, this technology must be for skeletal sites surrounded by layers of soft tissues, such as the spine and the hip. Soft tissue interferes with conventional imaging and using a more accessible area -- for example, the wrist or the ankle of limbs-- as a proxy for the less accessible skeletal regions, will not be accurate. A non-radioactive technology is strongly preferred.
How the embryo makes a limb: determination, polarity and identity
Tickle, Cheryll
2015-01-01
The vertebrate limb with its complex anatomy develops from a small bud of undifferentiated mesoderm cells encased in ectoderm. The bud has its own intrinsic polarity and can develop autonomously into a limb without reference to the rest of the embryo. In this review, recent advances are integrated with classical embryology, carried out mainly in chick embryos, to present an overview of how the embryo makes a limb bud. We will focus on how mesoderm cells in precise locations in the embryo become determined to form a limb and express the key transcription factors Tbx4 (leg/hindlimb) or Tbx5 (wing/forelimb). These Tbx transcription factors have equivalent functions in the control of bud formation by initiating a signalling cascade involving Wnts and fibroblast growth factors (FGFs) and by regulating recruitment of mesenchymal cells from the coelomic epithelium into the bud. The mesoderm that will form limb buds and the polarity of the buds is determined with respect to both antero-posterior and dorso-ventral axes of the body. The position in which a bud develops along the antero-posterior axis of the body will also determine its identity – wing/forelimb or leg/hindlimb. Hox gene activity, under the influence of retinoic acid signalling, is directly linked with the initiation of Tbx5 gene expression in the region along the antero-posterior axis of the body that will form wings/forelimbs and determines antero-posterior polarity of the buds. In contrast, Tbx4 expression in the regions that will form legs/hindlimbs is regulated by the homeoprotein Pitx1 and there is no evidence that Hox genes determine antero-posterior polarity of the buds. Bone morphogenetic protein (BMP) signalling determines the region along the dorso-ventral axis of the body in which both wings/forelimbs and legs/hindlimbs develop and dorso-ventral polarity of the buds. The polarity of the buds leads to the establishment of signalling regions – the dorsal and ventral ectoderm, producing Wnts and BMPs, respectively, the apical ectodermal ridge producing fibroblast growth factors and the polarizing region, Sonic hedgehog (Shh). These signals are the same in both wings/forelimbs and legs/hindlimbs and control growth and pattern formation by providing the mesoderm cells of the limb bud as it develops with positional information. The precise anatomy of the limb depends on the mesoderm cells in the developing bud interpreting positional information according to their identity – determined by Pitx1 in hindlimbs – and genotype. The competence to form a limb extends along the entire antero-posterior axis of the trunk – with Hox gene activity inhibiting the formation of forelimbs in the interlimb region – and also along the dorso-ventral axis. PMID:26249743
How the embryo makes a limb: determination, polarity and identity.
Tickle, Cheryll
2015-10-01
The vertebrate limb with its complex anatomy develops from a small bud of undifferentiated mesoderm cells encased in ectoderm. The bud has its own intrinsic polarity and can develop autonomously into a limb without reference to the rest of the embryo. In this review, recent advances are integrated with classical embryology, carried out mainly in chick embryos, to present an overview of how the embryo makes a limb bud. We will focus on how mesoderm cells in precise locations in the embryo become determined to form a limb and express the key transcription factors Tbx4 (leg/hindlimb) or Tbx5 (wing/forelimb). These Tbx transcription factors have equivalent functions in the control of bud formation by initiating a signalling cascade involving Wnts and fibroblast growth factors (FGFs) and by regulating recruitment of mesenchymal cells from the coelomic epithelium into the bud. The mesoderm that will form limb buds and the polarity of the buds is determined with respect to both antero-posterior and dorso-ventral axes of the body. The position in which a bud develops along the antero-posterior axis of the body will also determine its identity - wing/forelimb or leg/hindlimb. Hox gene activity, under the influence of retinoic acid signalling, is directly linked with the initiation of Tbx5 gene expression in the region along the antero-posterior axis of the body that will form wings/forelimbs and determines antero-posterior polarity of the buds. In contrast, Tbx4 expression in the regions that will form legs/hindlimbs is regulated by the homeoprotein Pitx1 and there is no evidence that Hox genes determine antero-posterior polarity of the buds. Bone morphogenetic protein (BMP) signalling determines the region along the dorso-ventral axis of the body in which both wings/forelimbs and legs/hindlimbs develop and dorso-ventral polarity of the buds. The polarity of the buds leads to the establishment of signalling regions - the dorsal and ventral ectoderm, producing Wnts and BMPs, respectively, the apical ectodermal ridge producing fibroblast growth factors and the polarizing region, Sonic hedgehog (Shh). These signals are the same in both wings/forelimbs and legs/hindlimbs and control growth and pattern formation by providing the mesoderm cells of the limb bud as it develops with positional information. The precise anatomy of the limb depends on the mesoderm cells in the developing bud interpreting positional information according to their identity - determined by Pitx1 in hindlimbs - and genotype. The competence to form a limb extends along the entire antero-posterior axis of the trunk - with Hox gene activity inhibiting the formation of forelimbs in the interlimb region - and also along the dorso-ventral axis. © 2015 Anatomical Society.
[Technological advances in neurorehabilitation].
Gutiérrez-Martínez, Josefina; Núñez-Gaona, Marco Antonio; Carrillo-Mora, Paul
2014-07-01
Neurological rehabilitation arose as formal method in the 60's, for the therapeutic treatment of patients with stroke or spinal cord injury, which develop severe sequelae that affect their motor and sensory abilities. Although the Central Nervous System has plasticity mechanisms for spontaneous recovery, a high percentage of patients should receive specialized therapies to regain motor function, such as Constraint Induced Movement Therapy or Upright physical Therapy. The neurorehabilitation has undergone drastic changes over the last two decades due to the incorporation of computer and robotic electronic devices, designed to produce positive changes in cortical excitability of the cerebral hemisphere damaged and so to improve neuroplasticity. Among equipment, we can mention those for electrotherapy devices, apparatus for transcranial magnetic stimulation, the robotic lower limb orthoses, robot for upper limb training, systems for functional electrical stimulation, neuroprosthesis and brain computer interfaces. These devices have caused controversy because of its application and benefits reported in the literature. The aim of Neurorehabilitation technologies is to take advantage of the functional neuromuscular structures preserved, and they compensate or re-learn the functions that previously made the damaged areas. The purpose of this article is to mention some clinical applications and benefits that these technologies offer to patients with neuronal injury.
Design and Implementation of a Mechanical Control System for the Scanning Microwave Limb Sounder
NASA Technical Reports Server (NTRS)
Bowden, William
2011-01-01
The Scanning Microwave Limb Sounder (SMLS) will use technological improvements in low noise mixers to provide precise data on the Earth's atmospheric composition with high spatial resolution. This project focuses on the design and implementation of a real time control system needed for airborne engineering tests of the SMLS. The system must coordinate the actuation of optical components using four motors with encoder readback, while collecting synchronized telemetric data from a GPS receiver and 3-axis gyrometric system. A graphical user interface for testing the control system was also designed using Python. Although the system could have been implemented with a FPGA-based setup, we chose to use a low cost processor development kit manufactured by XMOS. The XMOS architecture allows parallel execution of multiple tasks on separate threads-making it ideal for this application and is easily programmed using XC (a subset of C). The necessary communication interfaces were implemented in software, including Ethernet, with significant cost and time reduction compared to an FPGA-based approach. For these reasons, the XMOS technology is an attractive, cost effective, alternative to FPGA-based technologies for this design and similar rapid prototyping projects.
Bradley, Nina S; Solanki, Dhara; Zhao, Dawn
2005-12-01
New imaging technologies are revealing ever-greater details of motor behavior in fetuses for clinical diagnosis and treatment. Understanding the form, mechanisms, and significance of fetal behavior will maximize imaging applications. The chick is readily available for experimentation throughout embryogenesis, making it an excellent model for this purpose. Yet in 40 yr since Hamburger and colleagues described chick embryonic behavior, we have not determined if motility belongs to a developmental continuum fundamental to posthatching behavior. This study examined kinematics and synchronized electromyography (EMG) during spontaneous limb movements in chicks at four time points between embryonic days (E) 9-18. We report that coordinated kinematic and/or EMG patterns were expressed at each time point. Variability observed in knee and ankle excursions at E15-E18 sorted into distinct in-phase and out-of-phase patterns. EMG patterns did not directly account for out-of-phase patterns, indicating study of movement biomechanics will be critical to fully understand motor control in the embryo. We also provide the first descriptions of 2- to 10-Hz limb movements emerging E15-E18 and a shift from in-phase to out-of-phase interlimb coordination E9-E18. Our findings revealed that coordinated limb movements persist across development and suggest they belong to a developmental continuum for locomotion. Limb patterns were consistent with the half center model for a locomotor pattern generator. Achievement of these patterns by E9 may thus indicate the embryo has completed a critical phase beyond which developmental progression may be less vulnerable to experimental perturbations or prenatal events.
Ortiz-Catalan, Max; Sander, Nichlas; Kristoffersen, Morten B.; Håkansson, Bo; Brånemark, Rickard
2014-01-01
A variety of treatments have been historically used to alleviate phantom limb pain (PLP) with varying efficacy. Recently, virtual reality (VR) has been employed as a more sophisticated mirror therapy. Despite the advantages of VR over a conventional mirror, this approach has retained the use of the contralateral limb and is therefore restricted to unilateral amputees. Moreover, this strategy disregards the actual effort made by the patient to produce phantom motions. In this work, we investigate a treatment in which the virtual limb responds directly to myoelectric activity at the stump, while the illusion of a restored limb is enhanced through augmented reality (AR). Further, phantom motions are facilitated and encouraged through gaming. The proposed set of technologies was administered to a chronic PLP patient who has shown resistance to a variety of treatments (including mirror therapy) for 48 years. Individual and simultaneous phantom movements were predicted using myoelectric pattern recognition and were then used as input for VR and AR environments, as well as for a racing game. The sustained level of pain reported by the patient was gradually reduced to complete pain-free periods. The phantom posture initially reported as a strongly closed fist was gradually relaxed, interestingly resembling the neutral posture displayed by the virtual limb. The patient acquired the ability to freely move his phantom limb, and a telescopic effect was observed where the position of the phantom hand was restored to the anatomically correct distance. More importantly, the effect of the interventions was positively and noticeably perceived by the patient and his relatives. Despite the limitation of a single case study, the successful results of the proposed system in a patient for whom other medical and non-medical treatments have been ineffective justifies and motivates further investigation in a wider study. PMID:24616655
Ortiz-Catalan, Max; Sander, Nichlas; Kristoffersen, Morten B; Håkansson, Bo; Brånemark, Rickard
2014-01-01
A variety of treatments have been historically used to alleviate phantom limb pain (PLP) with varying efficacy. Recently, virtual reality (VR) has been employed as a more sophisticated mirror therapy. Despite the advantages of VR over a conventional mirror, this approach has retained the use of the contralateral limb and is therefore restricted to unilateral amputees. Moreover, this strategy disregards the actual effort made by the patient to produce phantom motions. In this work, we investigate a treatment in which the virtual limb responds directly to myoelectric activity at the stump, while the illusion of a restored limb is enhanced through augmented reality (AR). Further, phantom motions are facilitated and encouraged through gaming. The proposed set of technologies was administered to a chronic PLP patient who has shown resistance to a variety of treatments (including mirror therapy) for 48 years. Individual and simultaneous phantom movements were predicted using myoelectric pattern recognition and were then used as input for VR and AR environments, as well as for a racing game. The sustained level of pain reported by the patient was gradually reduced to complete pain-free periods. The phantom posture initially reported as a strongly closed fist was gradually relaxed, interestingly resembling the neutral posture displayed by the virtual limb. The patient acquired the ability to freely move his phantom limb, and a telescopic effect was observed where the position of the phantom hand was restored to the anatomically correct distance. More importantly, the effect of the interventions was positively and noticeably perceived by the patient and his relatives. Despite the limitation of a single case study, the successful results of the proposed system in a patient for whom other medical and non-medical treatments have been ineffective justifies and motivates further investigation in a wider study.
LIGNOSULFONATE-MODIFIED CALCIUM HYDROXIDE FOR SULFUR DIOXIDE CONTROL
The article discusses the use of lignosulfonate-modified calcium hydroxide Ca(OH)2 for sulfur dioxide (SO2) control. The limestone injection multistage burner (LIMB) process is currently being developed at the U.S. EPA as a low cost retrofittable technology for controlling oxides...
O'Reilly, Martin; Caulfield, Brian; Ward, Tomas; Johnston, William; Doherty, Cailbhe
2018-05-01
Analysis of lower limb exercises is traditionally completed with four distinct methods: (1) 3D motion capture; (2) depth-camera-based systems; (3) visual analysis from a qualified exercise professional; and (4) self-assessment. Each method is associated with a number of limitations. The aim of this systematic review is to synthesise and evaluate studies which have investigated the capacity for inertial measurement unit (IMU) technologies to assess movement quality in lower limb exercises. A systematic review of studies identified through the databases of PubMed, ScienceDirect and Scopus was conducted. Articles written in English and published in the last 10 years which investigated an IMU system for the analysis of repetition-based targeted lower limb exercises were included. The quality of included studies was measured using an adapted version of the STROBE assessment criteria for cross-sectional studies. The studies were categorised into three groupings: exercise detection, movement classification or measurement validation. Each study was then qualitatively summarised. From the 2452 articles that were identified with the search strategies, 47 papers are included in this review. Twenty-six of the 47 included studies were deemed as being of high quality. Wearable inertial sensor systems for analysing lower limb exercises is a rapidly growing field of research. Research over the past 10 years has predominantly focused on validating measurements that the systems produce and classifying users' exercise quality. There have been very few user evaluation studies and no clinical trials in this field to date.
Gravity-supported exercise with computer gaming improves arm function in chronic stroke.
Jordan, Kimberlee; Sampson, Michael; King, Marcus
2014-08-01
To investigate the effect of 4 to 6 weeks of exergaming with a computer mouse embedded within an arm skate on upper limb function in survivors of chronic stroke. Intervention study with a 4-week postintervention follow-up. In home. Survivors (N=13) of chronic (≥6 mo) stroke with hemiparesis of the upper limb with stable baseline Fugl-Meyer assessment scores received the intervention. One participant withdrew, and 2 participants were not reassessed at the 4-week follow-up. No participants withdrew as a result of adverse effects. Four to 6 weeks of exergaming using the arm skate where participants received either 9 (n=5) or 16 (n=7) hours of game play. Upper limb component of the Fugl-Meyer assessment. There was an average increase in the Fugl-Meyer upper limb assessment score from the beginning to end of the intervention of 4.9 points. At the end of the 4-week period after the intervention, the increase was 4.4 points. A 4- to 6-week intervention using the arm skate significantly improved arm function in survivors of chronic stroke by an average of 4.9 Fugl-Meyer upper limb assessment points. This research shows that a larger-scale randomized trial of this device is warranted and highlights the potential value of using virtual reality technology (eg, computer games) in a rehabilitation setting. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Lower limb compartment syndrome following laparoscopic colorectal surgery: a review.
Rao, M M; Jayne, D
2011-05-01
In spite of recent advances in technology and technique, laparoscopic colorectal surgery is associated with increased operating times when compared with open surgery. This increases the risk of acute lower limb compartment syndrome. The aim of this review was to gain a better understanding of postoperative lower limb compartment syndrome following laparoscopic colorectal surgery and to suggest strategies to avoid its occurrence. A MEDLINE search was performed using the keywords 'compartment syndrome', 'laparoscopic surgery' and 'Lloyd-Davies position' between 1970 and 2008. All relevant articles were retrieved and reviewed. A total of 54 articles were retrieved. Of the 30 articles in English, five were reviews, six were original articles and 19 were case reports, of which only one was following laparoscopic colorectal surgery. The remaining 24 were non-English articles. Of these, two were reviews and 22 were case reports, of which only one was following laparoscopic colorectal surgery. The incidence of acute compartment syndrome following laparoscopic colorectal surgery is unknown. The following are believed to be risk factors for acute lower limb compartment syndrome: the Lloyd-Davies operating position with exaggerated Trendelenburg tilt, prolonged operative times and improper patient positioning. Simple strategies are suggested to reduce its occurrence. Simple preventative measures have been identified which may help to reduce the incidence of acute lower limb compartment syndrome. However, if suspected, timely surgical intervention with four-compartment fasciotomy remains the standard of care. © 2011 The Authors. Colorectal Disease © 2011 The Association of Coloproctology of Great Britain and Ireland.
Sylos-Labini, Francesca; Ivanenko, Yuri P.
2014-01-01
Reduced gravity offers unique opportunities to study motor behavior. This paper aims at providing a review on current issues of the known tools and techniques used for hypogravity simulation and their effects on human locomotion. Walking and running rely on the limb oscillatory mechanics, and one way to change its dynamic properties is to modify the level of gravity. Gravity has a strong effect on the optimal rate of limb oscillations, optimal walking speed, and muscle activity patterns, and gait transitions occur smoothly and at slower speeds at lower gravity levels. Altered center of mass movements and interplay between stance and swing leg dynamics may challenge new forms of locomotion in a heterogravity environment. Furthermore, observations in the lack of gravity effects help to reveal the intrinsic properties of locomotor pattern generators and make evident facilitation of nonvoluntary limb stepping. In view of that, space neurosciences research has participated in the development of new technologies that can be used as an effective tool for gait rehabilitation. PMID:25247179
Earth Observations taken by the Expedition 23 Crew
2010-05-25
ISS023-E-057948 (25 May 2010) --- A sunset on the Indian Ocean is featured in this image photographed by an Expedition 23 crew member on the International Space Station (ISS). The image presents an edge-on, or limb view, of Earth’s atmosphere as seen from orbit. The Earth’s curvature is visible along the horizon line, or limb, that extends across the image from center left to lower right. Above the darkened surface of Earth, a brilliant sequence of colors roughly denotes several layers of the atmosphere. Deep oranges and yellows are visible in the troposphere that extends from Earth’s surface to 6-20 kilometers high. This layer contains over 80 percent of the mass of the atmosphere and almost all of the water vapor, clouds, and precipitation – several dark cloud layers are visible within this layer. Variations in the colors are due mainly to varying concentrations of either clouds or aerosols (airborne particles or droplets). The pink to white region above the clouds appears to be the stratosphere; this atmospheric layer generally has little or no clouds and extends up to approximately 50 kilometers above Earth’s surface. Above the stratosphere blue layers mark the upper atmosphere (including the mesosphere, thermosphere, ionosphere, and exosphere) as it gradually fades into the blackness of outer space. The ISS was located over the southern Indian Ocean when this image was taken, with the observer looking towards the west. Crew members aboard the space station see 16 sunrises and sunsets per day due to their high orbital velocity (greater than 28,000 kilometers per hour). The multiple chances for photography are fortunate, as at that speed each sunrise/sunset event only lasts a few seconds.
Mohta, Medha; Agarwal, Deepti; Sethi, AK
2011-01-01
Needle-through-needle combined spinal–epidural (CSE) may cause significant delay in patient positioning resulting in settling down of spinal anaesthetic and unacceptably low block level. Bilateral hip flexion has been shown to extend the spinal block by flattening lumbar lordosis. However, patients with lower limb fractures cannot flex their injured limb. This study was conducted to find out if unilateral hip flexion could extend the level of spinal anaesthesia following a prolonged CSE technique. Fifty American Society of Anesthesiologists (ASA) I/II males with unilateral femur fracture were randomly allocated to Control or Flexion groups. Needle-through-needle CSE was performed in the sitting position at L2-3 interspace and 2.6 ml 0.5% hyperbaric bupivacaine injected intrathecally. Patients were made supine 4 min after the spinal injection or later if epidural placement took longer. The Control group patients (n=25) lay supine with legs straight, whereas the Flexion group patients (n=25) had their uninjured hip and knee flexed for 5 min. Levels of sensory and motor blocks and time to epidural drug requirement were recorded. There was no significant difference in sensory levels at different time-points; maximum sensory and motor blocks; times to achieve maximum blocks; and time to epidural drug requirement in two groups. However, four patients in the Control group in contrast to none in the Flexion group required epidural drug before start of surgery. Moreover, in the Control group four patients took longer than 30 min to achieve maximum sensory block. To conclude, unilateral hip flexion did not extend the spinal anaesthetic level; however, further studies are required to explore the potential benefits of this technique. PMID:21808396
Clinical analysis of a large kindred with the pallister ulnar-mammary syndrome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bamshad, M.; Root, S.; Carey, J.C.
1996-11-11
The ulnar-mammary syndrome (UMS) is an autosomal dominant disorder characterized by posterior limb deficiencies or duplications, apocrine/mammary gland hypoplasia and/or dysfunction, abnormal dentition, delayed puberty in males, and genital anomalies. We present the clinical descriptions of 33 members of a six generation kindred with UMS. The number of affected individuals in this family is more than the sum of all previously reported cases of UMS. The clinical expression of UMS is highly variable. While most patients have limb deficiencies, the range of abnormalities extends from hypoplasia of the terminal phalanx of the 5th digit to complete absence of the ulnamore » and 3rd, 4th, and 5th digits. Moreover, affected individuals may have posterior digital duplications with or without contralateral limb deficiencies. Apocrine gland abnormalities range from diminished axillary perspiration with normal breast development and lactation, to complete absence of the breasts and no axillary perspiration. Dental abnormalities include misplaced or absent teeth. Affected males consistently undergo delayed puberty, and both sexes have diminished to absent axillary hair. Imperforate hymen were seen in some affected women. A gene for UMS was mapped to chromosome area 12q23-q24.1. A mutation in the gene causing UMS can interfere with limb patterning in the proximal/distal, anterior/posterior, and dorsal/ventral axes. This mutation disturbs development of the posterior elements of forearm, wrist, and hand while growth and development of the anterior elements remain normal. 24 refs., 4 figs., 1 tab.« less
People's experiences of suffering a lower limb fracture and undergoing surgery.
Forsberg, Angelica; Söderberg, Siv; Engström, Åsa
2014-01-01
To describe people's experiences of suffering a lower limb fracture and undergoing surgery, from the time of injury through to the care given at the hospital and recovery following discharge. There is a lack of research on people's experiences of suffering a lower limb fracture and undergoing surgery - from injury to recovery. A qualitative approach was used. Interviews with nine participants were subjected to thematic content analysis. One theme was expressed: from realising the seriousness of the injury to regaining autonomy. Participants described feelings of frustration and helplessness when realising the seriousness of their injury. The wait prior to surgery was a strain and painful experience, and participants needed orientation for the future. They expressed feelings of vulnerability about being in the hands of staff during surgery. After surgery, in the postanaesthesia unit, participants expressed a need to have control and to feel safe in their new situation. To mobilise and regain their autonomy was a struggle, and participants stated that their recovery was extended. Participants found themselves in a new and unexpected situation and experienced pain, vulnerability and a striving for control during the process, that is, 'from realising the seriousness of the injury to regaining autonomy'. How this is managed depends on how the patient's needs are met by nurses. The nursing care received while suffering a lower limb fracture and undergoing surgery should be situation specific as well as individual specific. The safe performance of technical interventions and the nurse's comprehensive explanations of medical terms may help the patient to feel secure during the process. © 2013 John Wiley & Sons Ltd.
Electromyography of wrist and finger flexor muscles in olive baboons (Papio anubis).
Patel, Biren A; Larson, Susan G; Stern, Jack T
2012-01-01
Some non-human primates use digitigrade hand postures when walking slowly on the ground. As a component of an extended limb, a digitigrade posture can help minimize wrist joint moments thereby requiring little force production directly from wrist flexors (and/or from the assistance of finger flexors) to maintain limb posture. As a consequence, less active muscle volume would be required from these anti-gravity muscles and overall metabolic costs associated with locomotion could be reduced. To investigate whether the use of digitigrade hand postures during walking in primates entails minimal use of anti-gravity muscles, this study examined electromyography (EMG) patterns in both the wrist and finger flexor muscles in facultatively digitigrade olive baboons (Papio anubis) across a range of speeds. The results demonstrate that baboons can adopt a digitigrade hand posture when standing and moving at slow speeds without requiring substantial EMG activity from distal anti-gravity muscles. Higher speed locomotion, however, entails increasing EMG activity and is accompanied by a dynamic shift to a more palmigrade-like limb posture. Thus, the ability to adopt a digitigrade hand posture by monkeys is an adaptation for ground living, but it was never co-opted for fast locomotion. Rather, digitigrady in primates appears to be related to energetic efficiency for walking long distances.
Folding associated with extensional faulting: Sheep Range detachment, southern Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guth, P.L.
1985-01-01
The Sheep Range detachment is a major Miocene extensional fault system of the Great Basin. Its major faults have a scoop shape, with straight, N-S traces extending 15-30 km and then abruptly turning to strike E-W. Tertiary deformation involved simultaneous normal faulting, sedimentation, landsliding, and strike-slip faulting. Folds occur in two settings: landslide blocks and drag along major faults. Folds occur in landslide blocks and beneath them. Most folds within landslide blocks are tight anticlines, with limbs dipping 40-60 degrees. Brecciation of the folds and landslide blocks suggests brittle deformation. Near Quijinump Canyon in the Sheep Range, at least threemore » landslide blocks (up to 500 by 1500 m) slid into a small Tertiary basin. Tertiary limestone beneath the Paleozoic blocks was isoclinally folded. Westward dips reveal drag folds along major normal faults, as regional dips are consistently to the east. The Chowderhead anticline is the largest drag fold, along an extensional fault that offsets Ordovician units 8 km. East-dipping Ordovician and Silurian rocks in the Desert Range form the hanging wall. East-dipping Cambrian and Ordovician units in the East Desert Range form the foot wall and east limb of the anticline. Caught along the fault plane, the anticline's west-dipping west limb contains mostly Cambrian units.« less
Wezenberg, Daphne; Cutti, Andrea G; Bruno, Antonino; Houdijk, Han
2014-01-01
Decreased push-off power by the prosthetic foot and inadequate roll-over shape of the foot have been shown to increase the energy dissipated during the step-to-step transition in human walking. The aim of this study was to determine whether energy storage and return (ESAR) feet are able to reduce the mechanical energy dissipated during the step-to-step transition. Fifteen males with a unilateral lower-limb amputation walked with their prescribed ESAR foot (Vari-Flex, Ossur; Reykjavik, Iceland) and with a solid-ankle cushioned heel foot (SACH) (1D10, Ottobock; Duderstadt, Germany), while ground reaction forces and kinematics were recorded. The positive mechanical work on the center of mass performed by the trailing prosthetic limb was larger (33%, p = 0.01) and the negative work performed by the leading intact limb was lower (13%, p = 0.04) when walking with the ESAR foot compared with the SACH foot. The reduced step-to-step transition cost coincided with a higher mechanical push-off power generated by the ESAR foot and an extended forward progression of the center of pressure under the prosthetic ESAR foot. Results can explain the proposed improvement in walking economy with this kind of energy storing and return prosthetic foot.
The fascia of the limbs and back – a review
Benjamin, Mike
2009-01-01
Although fasciae have long interested clinicians in a multitude of different clinical and paramedical disciplines, there have been few attempts to unite the ensuing diverse literature into a single review. The current article gives an anatomical perspective that extends from the gross to the molecular level. For expediency, it deals only with fascia in the limbs and back. Particular focus is directed towards deep fascia and thus consideration is given to structures such as the fascia lata, thoracolumbar fascia, plantar and palmar fascia, along with regional specializations of deep fascia such as retinacula and fibrous pulleys. However, equal emphasis is placed on general aspects of fascial structure and function, including its innervation and cellular composition. Among the many functions of fascia considered in detail are its ectoskeletal role (as a soft tissue skeleton for muscle attachments), its importance for creating osteofascial compartments for muscles, encouraging venous return in the lower limb, dissipating stress concentration at entheses and acting as a protective sheet for underlying structures. Emphasis is placed on recognizing the continuity of fascia between regions and appreciating its key role in coordinating muscular activity and acting as a body-wide proprioceptive organ. Such considerations far outweigh the significance of viewing fascia in a regional context alone. PMID:19166469
Morphology and the gradient of a symmetric potential predict gait transitions of dogs.
Wilshin, Simon; Haynes, G Clark; Porteous, Jack; Koditschek, Daniel; Revzen, Shai; Spence, Andrew J
2017-08-01
Gaits and gait transitions play a central role in the movement of animals. Symmetry is thought to govern the structure of the nervous system, and constrain the limb motions of quadrupeds. We quantify the symmetry of dog gaits with respect to combinations of bilateral, fore-aft, and spatio-temporal symmetry groups. We tested the ability of symmetries to model motion capture data of dogs walking, trotting and transitioning between those gaits. Fully symmetric models performed comparably to asymmetric with only a [Formula: see text] increase in the residual sum of squares and only one-quarter of the parameters. This required adding a spatio-temporal shift representing a lag between fore and hind limbs. Without this shift, the symmetric model residual sum of squares was [Formula: see text] larger. This shift is related to (linear regression, [Formula: see text], [Formula: see text]) dog morphology. That this symmetry is respected throughout the gaits and transitions indicates that it generalizes outside a single gait. We propose that relative phasing of limb motions can be described by an interaction potential with a symmetric structure. This approach can be extended to the study of interaction of neurodynamic and kinematic variables, providing a system-level model that couples neuronal central pattern generator networks and mechanical models.
NASA Astrophysics Data System (ADS)
de la Paz, Mercedes; García-Ibáñez, Maribel I.; Steinfeldt, Reiner; Ríos, Aida F.; Pérez, Fiz F.
2017-04-01
The extent to which water mass mixing and ocean ventilation contribute to nitrous oxide (N2O) distribution at the scale of oceanic basins is poorly constrained. We used novel N2O and chlorofluorocarbon measurements along with multiparameter water mass analysis to evaluate the impact of water mass mixing and Atlantic Meridional Overturning Circulation (AMOC) on N2O distribution along the Observatoire de la variabilité interannuelle et décennale en Atlantique Nord (OVIDE) section, extending from Portugal to Greenland. The biological N2O production has a stronger impact on the observed N2O concentrations in the water masses traveling northward in the upper limb of the AMOC than those in recently ventilated cold water masses in the lower limb, where N2O concentrations reflect the colder temperatures. The high N2O tongue, with concentrations as high as 16 nmol kg-1, propagates above the isopycnal surface delimiting the upper and lower AMOC limbs, which extends from the eastern North Atlantic Basin to the Iceland Basin and coincides with the maximum N2O production rates. Water mixing and basin-scale remineralization account for 72% of variation in the observed distribution of N2O. The mixing-corrected stoichiometric ratio N2O:O2 for the North Atlantic Basin of 0.06 nmol/μmol is in agreement with ratios of N2O:O2 for local N2O anomalies, suggesting than up to 28% of N2O production occurs in the temperate and subpolar Atlantic, an overlooked region for N2O cycling. Overall, our results highlight the importance of taking into account mixing, O2 undersaturation when water masses are formed and the increasing atmospheric N2O concentrations when parameterizing N2O:O2 and biological N2O production in the global oceans.
Grasso, R; Peppe, A; Stratta, F; Angelini, D; Zago, M; Stanzione, P; Lacquaniti, F
1999-05-01
Gait coordination was analyzed (four-camera 100 Hz ELITE system) in two groups of idiopathic Parkinson disease (PD) patients. Five patients underwent continuous infusion of apomorphine and were recorded in two different sessions (APO OFF and APO ON) in the same day. Three patients with a previous chronic electrode implantation in both internal globi pallidi (GPi) were recorded in the same experimental session with the electrodes on and off (STIM ON and STIM OFF). The orientation of both the trunk and the lower-limb segments was described with respect to the vertical in the sagittal plane. Lower-limb inter-segmental coordination was evaluated by analyzing the co-variation between thigh, shank, and foot elevation angles by means of orthogonal planar regression. At least 30 gait cycles per experimental condition were processed. We found that the trunk was bent forward in STIM OFF, whereas it was better aligned with the vertical in STIM ON in both PD groups. The legs never fully extended during the gait cycle in STIM OFF, whereas they extended before heel strike in STIM ON. The multisegmental coordination of the lower limb changed almost in parallel with the changes in trunk orientation. In STIM OFF, both the shape and the spatial orientation of the planar gait loops (thigh angle vs. shank angle vs. foot angle) differed from those of physiological locomotion, whereas in STIM ON the gait loop tended to resume features closer to the control. Switching the electrodes on and off in patients with GPi electrodes resulted in quasi-parallel changes of the trunk inclination and of the planar gait loop. The bulk of the data suggest that the basal-ganglia circuitry may be relevant in locomotion by providing an appropriate spatio-temporal framework for the control of posture and movement in a gravity-based body-centered frame of reference. Pallido-thalamic and/or pallido-mesencephalic pathways may influence the timing of the inter-segmental coordination for gait.
ON THE RETRIEVAL OF MESOSPHERIC WINDS ON MARS AND VENUS FROM GROUND-BASED OBSERVATIONS AT 10 μm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopez-Valverde, M. A.; Montabone, L.; Sornig, M.
A detailed analysis is presented of ground-based observations of atmospheric emissions on Mars and Venus under non-local thermodynamic equilibrium (non-LTE) conditions at high spectral resolution. Our first goal is to comprehend the difficulties behind the derivation of wind speeds from ground-based observations. A second goal is to set a framework to permit comparisons with other observations and with atmospheric models. A forward model including non-LTE radiative transfer is used to evaluate the information content within the telescopic beam, and is later convolved with the beam function and a typical wind field to discern the major contributions to the measured radiance,more » including limb and nadir views. The emission mostly arises from the non-LTE limb around altitudes of 75 km on Mars and 110 km on Venus. We propose a parameterization of the limb emission using few geophysical parameters which can be extended to other hypothetical CO{sub 2} planetary atmospheres. The tropospheric or LTE component of the emission varies with the temperature and is important at low solar illumination but only for the emerging radiance, not for the wind determinations since these are derived from the Doppler shift at the non-LTE line cores. We evaluated the sources of uncertainty and found that the forward model errors amount to approximately 12% of the measured winds, which is normally smaller than the instrumental errors. We applied this study to revise a set of measurements extending for three Martian years and confirmed previous results suggesting winds that are too large simulated by current Martian circulation models at equatorial latitudes during solstice. We encourage new observational campaigns, particularly for the strong jet at mid–high latitudes on Mars, and propose general guidelines and recommendations for future observations.« less
Post-flare loops embedded in a hot coronal fan-like structure
NASA Technical Reports Server (NTRS)
Svestka, Z.; Farnik, F.; Hudson, H. S.; Hick, P.
1997-01-01
Limb events were demonstrated on the sun in which rising post-flare loops were embedded in hot structures looking in soft X-rays like fans of rays, formed during the flare and extending high into the corona. One of these structures is analyzed and it is suggested that these fans of rays represent temporary ministreamers, along which mass flows into interplanetary space. This suggestion is supported by maps of solar wind density constructed from scintillation measurements.
Workshop on "New Engineering Technology Transfer in Orthopaedic Surgery".
1999-04-01
anatomy is required to remain oriented to the tunnel -view of the arthroscope as is the ability to triangulate the instruments through proprioception...required. Methods: Eight limbs from fresh, whole cadavers were used. Motion data were collected with the OPTOTRAK infrared motion analysis system
Huang, Han-Wei; Ju, Ming-Shaung; Lin, Chou-Ching K
2016-05-01
The aim of this study was to evaluate the flexor and extensor muscle tone of the upper limbs in patients with spasticity or rigidity and to investigate the difference in hypertonia between spasticity and rigidity. The two experimental groups consisted of stroke patients and parkinsonian patients. The control group consisted of age and sex-matched normal subjects. Quantitative upper limb pendulum tests starting from both flexed and extended joint positions were conducted. System identification with a simple linear model was performed and model parameters were derived. The differences between the three groups and two starting positions were investigated by these model parameters and tested by two-way analysis of variance. In total, 57 subjects were recruited, including 22 controls, 14 stroke patients and 21 parkinsonian patients. While stiffness coefficient showed no difference among groups, the number of swings, relaxation index and damping coefficient showed changes suggesting significant hypertonia in the two patient groups. There was no difference between these two patient groups. The test starting from the extended position constantly manifested higher muscle tone in all three groups. In conclusion, the hypertonia of parkinsonian and stroke patients could not be differentiated by the modified pendulum test; the elbow extensors showed a higher muscle tone in both control and patient groups; and hypertonia of both parkinsonian and stroke patients is velocity dependent. Copyright © 2015 Elsevier Ltd. All rights reserved.
Earle, Rosie; Vaghadia, Himat; Shanahan, Enda; Tang, Raymond; Sawka, Andrew
2016-11-01
We report the novel application of photoplethysmographic technology with the Nexfin HD monitor for real-time measurement of blood pressure (BP) in a patient with tetraamelia. The patient was a 58-year-old man with tetraamelia secondary to thalidomide exposure in utero, who presented for surgical excision of a maxillary schwannoma. Because difficulty of cuff use on rudimentary limbs and failure to gain invasive arterial access due to abnormalities of limb vasculature, this population is known to pose some unique challenges for BP measurement. Nexfin may offer an alternative noninvasive method to detect BP in patients with phocomelia during the perioperative period. Copyright © 2016 Elsevier Inc. All rights reserved.
2011-10-01
been developed. The next step is to develop a the base technology into a grid like mapping sensor, construct the excitation and detection circuits...the project involves advancing the base technology into a grid -like mapping se nsor, constructing the excitation and detection circuits, modifying and...further. In conclusion, the screen printing and etching process allows for precise repeat able production of sensing elements for grid fabrication
Hoermann, Simon; Ferreira Dos Santos, Luara; Morkisch, Nadine; Jettkowski, Katrin; Sillis, Moran; Devan, Hemakumar; Kanagasabai, Parimala S; Schmidt, Henning; Krüger, Jörg; Dohle, Christian; Regenbrecht, Holger; Hale, Leigh; Cutfield, Nicholas J
2017-07-01
New rehabilitation strategies for post-stroke upper limb rehabilitation employing visual stimulation show promising results, however, cost-efficient and clinically feasible ways to provide these interventions are still lacking. An integral step is to translate recent technological advances, such as in virtual and augmented reality, into therapeutic practice to improve outcomes for patients. This requires research on the adaptation of the technology for clinical use as well as on the appropriate guidelines and protocols for sustainable integration into therapeutic routines. Here, we present and evaluate a novel and affordable augmented reality system (Augmented Reflection Technology, ART) in combination with a validated mirror therapy protocol for upper limb rehabilitation after stroke. We evaluated components of the therapeutic intervention, from the patients' and the therapists' points of view in a clinical feasibility study at a rehabilitation centre. We also assessed the integration of ART as an adjunct therapy for the clinical rehabilitation of subacute patients at two different hospitals. The results showed that the combination and application of the Berlin Protocol for Mirror Therapy together with ART was feasible for clinical use. This combination was integrated into the therapeutic plan of subacute stroke patients at the two clinical locations where the second part of this research was conducted. Our findings pave the way for using technology to provide mirror therapy in clinical settings and show potential for the more effective use of inpatient time and enhanced recoveries for patients. Implications for Rehabilitation Computerised Mirror Therapy is feasible for clinical use Augmented Reflection Technology can be integrated as an adjunctive therapeutic intervention for subacute stroke patients in an inpatient setting Virtual Rehabilitation devices such as Augmented Reflection Technology have considerable potential to enhance stroke rehabilitation.
Multi-limbed locomotion systems for space construction and maintenance
NASA Technical Reports Server (NTRS)
Waldron, K. J.; Klein, C. A.
1987-01-01
A well developed technology of coordination of multi-limbed locomotory systems is now available. Results from a NASA sponsored study of several years ago are presented. This was a simulation study of a three-limbed locomotion/manipulation system. Each limb had six degrees of freedom and could be used either as a locomotory grasping hand-holds, or as a manipulator. The focus of the study was kinematic coordination algorithms. The presentation will also include very recent results from the Adaptive Suspension Vehicle Project. The Adaptive Suspension Vehicle (ASV) is a legged locomotion system designed for terrestrial use which is capable of operating in completely unstructured terrain in either a teleoperated or operator-on-board mode. Future development may include autonomous operation. The ASV features a very advanced coordination and control system which could readily be adapted to operation in space. An inertial package with a vertical gyro, and rate gyros and accelerometers on three orthogonal axes provides body position information at high bandwidth. This is compared to the operator's commands, injected via a joystick to provide a commanded force system on the vehicle's body. This system is, in turn, decomposed by a coordination algorithm into force commands to those legs which are in contact with the ground.
NASA Astrophysics Data System (ADS)
Xu, Xiaorong; Zhu, Wen; Padival, Vikram; Xia, Mengna; Cheng, Xuefeng; Bush, Robin; Christenson, Linda; Chan, Tim; Doherty, Tim; Iatridis, Angelo
2003-07-01
Photonify"s tissue spectrometer uses Near-Infrared Spectroscopy for real-time, noninvasive measurement of hemoglobin concentration and oxygen saturation [SO2] of biological tissues. The technology was validated by a series of ex vivo and animal studies. In the ex vivo experiment, a close loop blood circulation system was built, precisely controlling the oxygen saturation and the hemoglobin concentration of a liquid phantom. Photonify"s tissue spectrometer was placed on the surface of the liquid phantom for real time measurement and compared with a gas analyzer, considered the gold standard to measure oxygen saturation and hemoglobin concentration. In the animal experiment, the right hind limb of each dog accepted onto the study was surgically removed. The limb was kept viable by connecting the femoral vein and artery to a blood-primed extracorporeal circuit. Different concentrations of hemoglobin were obtained by adding designated amount of saline solution into the perfusion circuit. Photonify"s tissue spectrometers measured oxygen saturation and hemoglobin concentration at various locations on the limb and compared with gas analyzer results. The test results demonstrated that Photonify"s tissue spectrometers were able to detect the relative changes in tissue oxygen saturation and hemoglobin concentration with a high linear correlation compared to the gas analyzer
Meadmore, Katie L; Cai, Zhonglun; Tong, Daisy; Hughes, Ann-Marie; Freeman, Chris T; Rogers, Eric; Burridge, Jane H
2011-01-01
A novel system has been developed which combines robotic therapy with electrical stimulation (ES) for upper limb stroke rehabilitation. This technology, termed SAIL: Stimulation Assistance through Iterative Learning, employs advanced model-based iterative learning control (ILC) algorithms to precisely assist participant's completion of 3D tracking tasks with their impaired arm. Data is reported from a preliminary study with unimpaired participants, and also from a single hemiparetic stroke participant with reduced upper limb function who has used the system in a clinical trial. All participants completed tasks which involved moving their (impaired) arm to follow an image of a slowing moving sphere along a trajectory. The participants' arm was supported by a robot and ES was applied to the triceps brachii and anterior deltoid muscles. During each task, the same tracking trajectory was repeated 6 times and ILC was used to compute the stimulation signals to be applied on the next iteration. Unimpaired participants took part in a single, one hour training session and the stroke participant undertook 18, 1 hour treatment sessions composed of tracking tasks varying in length, orientation and speed. The results reported describe changes in tracking ability and demonstrate feasibility of the SAIL system for upper limb rehabilitation. © 2011 IEEE
Mansoor, Awais; Ahmed, Wamiq M; Samarapungavan, Ala; Cirillo, John; Schwarte, David; Robinson, J Paul; Duerstock, Bradley S
2010-01-01
A web-based application was developed to remotely view slide specimens and control all functions of a research-level light microscopy workstation, called AccessScope. Students and scientists with upper limb mobility and visual impairments are often unable to use a light microscope by themselves and must depend on others in its operation. Users with upper limb mobility impairments and low vision were recruited to assist in the design process of the AccessScope personal computer (PC) user interface. Participants with these disabilities were evaluated in their ability to use AccessScope to perform microscopical tasks. AccessScope usage was compared with inspecting prescanned slide images by grading participants' identification and understanding of histological features and knowledge of microscope operation. With AccessScope subjects were able to independently perform common light microscopy functions through an Internet browser by employing different PC pointing devices or accessibility software according to individual abilities. Subjects answered more histology and microscope usage questions correctly after first participating in an AccessScope test session. AccessScope allowed users with upper limb or visual impairments to successfully perform light microscopy without assistance. This unprecedented capability is crucial for students and scientists with disabilities to perform laboratory coursework or microscope-based research and pursue science, technology, engineering, and mathematics fields.
NASA Technical Reports Server (NTRS)
Ziemke, J. R.; Kramarova, N. A.; Bhartia, P. K.; Degenstein, D. A.; Deland, M. T.
2016-01-01
Since October 2004 the Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS) onboard the Aura satellite have provided over 11 years of continuous tropospheric ozone measurements. These OMI/MLS measurements have been used in many studies to evaluate dynamical and photochemical effects caused by ENSO, the Madden-Julian Oscillation (MJO) and shorter timescales, as well as long-term trends and the effects of deep convection on tropospheric ozone. Given that the OMI and MLS instruments have now extended well beyond their expected lifetimes, our goal is to continue their long record of tropospheric ozone using recent Ozone Mapping Profiler Suite (OMPS) measurements. The OMPS onboard the Suomi National Polar-orbiting Partnership NPP satellite was launched on October 28, 2011 and is comprised of three instruments: the nadir mapper, the nadir profiler, and the limb profiler. Our study combines total column ozone from the OMPS nadir mapper with stratospheric column ozone from the OMPS limb profiler to measure tropospheric ozone residual. The time period for the OMPS measurements is March 2012 present. For the OMPS limb profiler retrievals, the OMPS v2 algorithm from Goddard is tested against the University of Saskatchewan (USask) Algorithm. The retrieved ozone profiles from each of these algorithms are evaluated with ozone profiles from both ozonesondes and the Aura Microwave Limb Sounder (MLS). Effects on derived OMPS tropospheric ozone caused by the 2015-2016 El Nino event are highlighted. This recent El Nino produced anomalies in tropospheric ozone throughout the tropical Pacific involving increases of approximately 10 DU over Indonesia and decreases approximately 5-10 DU in the eastern Pacific. These changes in ozone due to El Nino were predominantly dynamically-induced, caused by the eastward shift in sea-surface temperature and convection from the western to the eastern Pacific.
Moncada-Torres, A; Leuenberger, K; Gonzenbach, R; Luft, A; Gassert, R
2014-07-01
Miniature, wearable sensor modules are a promising technology to monitor activities of daily living (ADL) over extended periods of time. To assure both user compliance and meaningful results, the selection and placement site of sensors requires careful consideration. We investigated these aspects for the classification of 16 ADL in 6 healthy subjects under laboratory conditions using ReSense, our custom-made inertial measurement unit enhanced with a barometric pressure sensor used to capture activity-related altitude changes. Subjects wore a module on each wrist and ankle, and one on the trunk. Activities comprised whole body movements as well as gross and dextrous upper-limb activities. Wrist-module data outperformed the other locations for the three activity groups. Specifically, overall classification accuracy rates of almost 93% and more than 95% were achieved for the repeated holdout and user-specific validation methods, respectively, for all 16 activities. Including the altitude profile resulted in a considerable improvement of up to 20% in the classification accuracy for stair ascent and descent. The gyroscopes provided no useful information for activity classification under this scheme. The proposed sensor setting could allow for robust long-term activity monitoring with high compliance in different patient populations.
Practicing Rhetoric Without Speaking.
ERIC Educational Resources Information Center
Johnson, Ralph A.
Just as strong limbs do not ensure self-defense in an age of modern warfare, so strong persuasive appeals do not ensure self-defense in an age of highly technologized communication systems. The fragmentation of the audience, the inherent loss of credibility associated with the decreased status of rhetoric, and the competition among messages all…
Emergency Preparedness: Life, Limb, the Pursuit of Safety and Social Justice
ERIC Educational Resources Information Center
Russo, Marianne Robin; Bryan, Valerie C.; Penney, Gerri
2012-01-01
Since 9-11, emergency preparedness has been the focus on federal, state, tribal, and local levels. Although current research describes emergency management response, many barriers may exist that effect response systems, including the role of first responders, social vulnerability, and the way technology interfaces with these variables. Several…
ERIC Educational Resources Information Center
Roman, Harry T.
2014-01-01
Biomedical and robotic technologies are merging to present a wonderful opportunity to develop artificial limbs and prosthetic devices for humans injured on the job, in the military, or due to disease. In this challenge, students will have the opportunity to design a store or online service that specifically dedicates itself to amputees. Described…
Ricci, Luca; Formica, Domenico; Sparaci, Laura; Lasorsa, Francesca Romana; Taffoni, Fabrizio; Tamilia, Eleonora; Guglielmelli, Eugenio
2014-01-09
Recent advances in wearable sensor technologies for motion capture have produced devices, mainly based on magneto and inertial measurement units (M-IMU), that are now suitable for out-of-the-lab use with children. In fact, the reduced size, weight and the wireless connectivity meet the requirement of minimum obtrusivity and give scientists the possibility to analyze children's motion in daily life contexts. Typical use of magneto and inertial measurement units (M-IMU) motion capture systems is based on attaching a sensing unit to each body segment of interest. The correct use of this setup requires a specific calibration methodology that allows mapping measurements from the sensors' frames of reference into useful kinematic information in the human limbs' frames of reference. The present work addresses this specific issue, presenting a calibration protocol to capture the kinematics of the upper limbs and thorax in typically developing (TD) children. The proposed method allows the construction, on each body segment, of a meaningful system of coordinates that are representative of real physiological motions and that are referred to as functional frames (FFs). We will also present a novel cost function for the Levenberg-Marquardt algorithm, to retrieve the rotation matrices between each sensor frame (SF) and the corresponding FF. Reported results on a group of 40 children suggest that the method is repeatable and reliable, opening the way to the extensive use of this technology for out-of-the-lab motion capture in children.
ERIC Educational Resources Information Center
Wu, Xiaoyu; Gao, Yuan
2011-01-01
This paper applies the extended technology acceptance model (exTAM) in information systems research to the use of clickers in student learning. The technology acceptance model (TAM) posits that perceived ease of use and perceived usefulness of technology influence users' attitudes toward using and intention to use technology. Research subsequent…
Surveying the interest of individuals with upper limb loss in novel prosthetic control techniques.
Engdahl, Susannah M; Christie, Breanne P; Kelly, Brian; Davis, Alicia; Chestek, Cynthia A; Gates, Deanna H
2015-06-13
Novel techniques for the control of upper limb prostheses may allow users to operate more complex prostheses than those that are currently available. Because many of these techniques are surgically invasive, it is important to understand whether individuals with upper limb loss would accept the associated risks in order to use a prosthesis. An online survey of individuals with upper limb loss was conducted. Participants read descriptions of four prosthetic control techniques. One technique was noninvasive (myoelectric) and three were invasive (targeted muscle reinnervation, peripheral nerve interfaces, cortical interfaces). Participants rated how likely they were to try each technique if it offered each of six different functional features. They also rated their general interest in each of the six features. A two-way repeated measures analysis of variance with Greenhouse-Geisser corrections was used to examine the effect of the technique type and feature on participants' interest in each technique. Responses from 104 individuals were analyzed. Many participants were interested in trying the techniques - 83 % responded positively toward myoelectric control, 63 % toward targeted muscle reinnervation, 68 % toward peripheral nerve interfaces, and 39 % toward cortical interfaces. Common concerns about myoelectric control were weight, cost, durability, and difficulty of use, while the most common concern about the invasive techniques was surgical risk. Participants expressed greatest interest in basic prosthesis features (e.g., opening and closing the hand slowly), as opposed to advanced features like fine motor control and touch sensation. The results of these investigations may be used to inform the development of future prosthetic technologies that are appealing to individuals with upper limb loss.
GH/IGF-I Transgene Expression on Muscle Homeostasis
NASA Technical Reports Server (NTRS)
Schwartz, Robert J.
1999-01-01
We propose to test the hypothesis that the growth hormone/ insulin like growth factor-I axis through autocrine/paracrine mechanisms may provide long term muscle homeostasis under conditions of prolonged weightlessness. As a key alternative to hormone replacement therapy, ectopic production of hGH, growth hormone releasing hormone (GHRH), and IGF-I will be studied for its potential on muscle mass impact in transgenic mice under simulated microgravity. Expression of either hGH or IGF-I would provide a chronic source of a growth-promoting protein whose biosynthesis or secretion is shut down in space. Muscle expression of the IGF-I transgene has demonstrated about a 20% increase in hind limb muscle mass over control nontransgenic litter mates. These recent experiments, also establish the utility of hind-limb suspension in mice as a workable model to study atrophy in weight bearing muscles. Thus, transgenic mice will be used in hind-limb suspension models to determine the role of GH/IGF-I on maintenance of muscle mass and whether concentric exercises might act in synergy with hormone treatment. As a means to engineer and ensure long-term protein production that would be workable in humans, gene therapy technology will be used by to monitor muscle mass preservation during hind-limb suspension, after direct intramuscular injection of a genetically engineered muscle-specific vector expressing GHRH. Effects of this gene-based therapy will be assessed in both fast twitch (medial gastrocnemius) and slow twitch muscle (soleus). End-points include muscle size, ultrastructure, fiber type, and contractile function, in normal animals, hind limb suspension, and reambutation.
NASA Technical Reports Server (NTRS)
Suess, S. T.; Poletto, G.
2007-01-01
During quadrature, plasma seen on the limb of the Sun, along the radi al direction to Ulysses, by SOHO or STEREO can be sampled in situ as lt later passes Ulysses. A figure shows a coronagraph image, the rad ial towards Ulysses at 58 deg. S. and the SOHO/UVCS slit positions d uring one set of observations. A CME subsequently occurred and passed Ulysses (at 3/4 AU) 15 days later.
Expedition Seven Takes Breathtaking Photo of Earth's Atmosphere
NASA Technical Reports Server (NTRS)
2003-01-01
This Expedition Seven image, taken while aboard the International Space Station (ISS), shows the limb of the Earth at the bottom transitioning into the orange-colored stratosphere, the lowest and most dense portion of the Earth's atmosphere. The troposphere ends abruptly at the tropopause, which appears in the image as the sharp boundary between the orange- and blue-colored atmosphere. The silvery blue noctilucent clouds extend far above the Earth's troposphere. The silver of the setting moon is visible at upper right.
2012-03-30
as though uncomfortable (CNS adverse overdose reaction seen in hu- mans), with body movements such as extension of the limbs. One animal had...would account for the dra- matic results noted in the present experiments. VPA is a drug that has been accidentally or in- tentionally overdosed many...a large proportion of the VPA is free, exacerbating its effects. Normal half life is 7-15 hrs [34] but can be extended by overdose . Serum
Myxofibrosarcoma - Case report*
de Castro, Breno Augusto Campos; Piancastelli, André Costa Cruz; Meyer, Renata Leal Bregunci; Piancastelli, Patricia Mourthe; Ribeiro, Carlos Alberto; Miranda, Rubem Mateus Campos
2016-01-01
Myxofibrosarcoma is recognized as a malignant neoplasm of fibroblastic origin with increased prevalence in the elderly, presenting as nodules or tumors that may extend to the dermis and skeletal muscle, preferably in the lower limbs. Histologically it is characterized by a proliferation of spindle cells in a myxoid stroma. Myxofibrosarcoma has a high potential for local recurrence and metastasis, mainly when it presents a high or intermediate histological grade. We report the case of an eighty-four year old patient with a difficult diagnosis of a highly aggressive tumor. PMID:26982788
2010-04-01
that are now digitally enhanced and also part-task trainers (attrappe). Paper 12 – Using Advanced Prosthetics for Stress Inoculation Training and to...concept of minimum treatment called the “Just seven procedure”: just bridge the fracture , just align the limb, just stiff enough to allow evacuation...require energy, some more than others. Oxygen economizing systems like on-demand valves should be compulsory for spontaneous ventilation. Pulseoximeters
Hysteretic behavior of stage-discharge relationships in urban streams
NASA Astrophysics Data System (ADS)
Miller, A. J.; Lindner, G. A.
2009-12-01
Reliable stage-discharge relationships or rating curves are of critical importance for accurate calculation of streamflow and maintenance of long-term flow records. Urban streams offer particular challenges for the maintenance of accurate rating curves. It is often difficult or impossible to collect direct discharge measurements at high flows, many of which are generated by short-duration high-intensity summer thunderstorms, both because of dangerous conditions in the channel and also because the stream rises and falls so rapidly that field crews cannot reach sites in time and sometimes cannot make measurements rapidly enough to keep pace with changing water levels even when they are on site during a storm. Work in urban streams in the Baltimore metropolitan area has shown that projection of rating curves beyond the range of measured flows can lead to overestimation of flood peaks by as much as 100%, and these can only be corrected when adequate field data are available to support modeling efforts. Even moderate flows that are above safe wading depth and velocity may best be estimated using hydraulic models. Current research for NSF CNH project 0709659 includes the application of 2-d depth-averaged hydraulic models to match existing rating curves over a range of low to moderate flows and to extend rating curves for higher flows, based on field collection of high-water marks. Although it is generally assumed that stage-discharge relationships are single-valued, we find that modeling results in small urban streams often generate hysteretic relationships, with higher discharges on the rising limb of the hydrograph than on the falling limb. The difference between discharges for the same stage on the rising and falling limb can be on the order of 20-30% even for in-channel flows that are less than 1 m deep. As safety considerations dictate that it is preferable to make direct discharge measurements on the falling limb of the hydrograph, the higher direct measurements used in many rating curves probably have been collected on the falling limb and therefore may not capture the correct stage-discharge relationship for the rising limb. In some cases model results selected only from the falling limb are able to match the existing rating curve very closely. Although hysteresis may be explained with reference to the innate properties of the flood wave, other factors also lead to hysteretic behavior. Downstream constrictions and obstructions associated with urban infrastructure may cause substantial backwater effects, particularly during flood flows. Flood conditions at tributary confluences also can exert a controlling influence upstream. Based on our results we recommend that at some sites it is advisable to develop separate rating curves for the rising and falling limbs, and to develop a range of modeling scenarios for predicting the range of potential uncertainty.
... Treatment Window for Stroke Follow us Brain Scan Technology Extends Treatment Window for Stroke Some stroke patients ... after a stroke happens—thanks to brain imaging technology. But researchers emphasize that stroke is still an ...
Schaffalitzky, Elisabeth; NiMhurchadha, Sinead; Gallagher, Pamela; Hofkamp, Susan; MacLachlan, Malcolm; Wegener, Stephen T
2009-06-01
The matching of prosthetic devices to the needs of the individual is a challenge for providers and patients. The aims of this study are to explore the values and preferences that prosthetic users have of their prosthetic devices; to investigate users' perceptions of alternative prosthetic options and to demonstrate a novel method for exploring the values and preferences of prosthetic users. This study describes four case studies of upper limb and lower limb high tech and conventional prosthetic users. Participants were interviewed using the repertory grid technique (RGT), a qualitative technique to explore individual values and preferences regarding specific choices and events. The participants generated distinctive patterns of personal constructs and ratings regarding prosthetic use and different prosthetic options available. The RGT produced a unique profile of preferences regarding prosthetic technologies for each participant. User choice is an important factor when matching prosthetic technology to the user. The consumer's values regarding different prosthetic options are likely to be a critical factor in prosthetic acceptance and ultimate quality of life. The RGT offers a structured method of exploring these attitudes and values without imposing researcher or practitioner bias and identifies personalized dimensions for providers and users to evaluate the individuals' preferences in prosthetic technology.
Bird, M L; Cannell, J; Callisaya, M L; Moles, E; Rathjen, A; Lane, K; Tyson, A; Smith, S
2016-04-16
Stroke results in significant disability, which can be reduced by physical rehabilitation. High levels of repetition and activity are required in rehabilitation, but patients are typically sedentary. Using clinically relevant and fun computer games may be one way to achieve increased activity in rehabilitation. A single-blind randomized controlled trial will be conducted to evaluate the feasibility, efficacy and safety of novel stroke-specific rehabilitation software. This software uses controller-free client interaction and inertial motion sensors. Elements of feasibility include recruitment into the trial, ongoing participation (adherence and dropout), perceived benefit, enjoyment and ease of use of the games. Efficacy will be determined by measuring activity and using upper-limb tasks as well as measures of balance and mobility. The hypothesis that the intervention group will have increased levels of physical activity within rehabilitation and improved physical outcomes compared with the control group will be tested. Results from this study will provide a basis for discussion of feasibility of this interactive video technological solution in an inpatient situation. Differences in activity levels between groups will be the primary measure of efficacy. It will also provide data on measures of upper-limb function, balance and mobility. ACTRN12614000427673 . Prospectively registered 17 April 2014.
ERIC Educational Resources Information Center
Tarhini, Ali; Elyas, Tariq; Akour, Mohammad Ali; Al-Salti, Zahran
2016-01-01
The main aim of this paper is to develop an amalgamated conceptual model of technology acceptance that explains how individual, social, cultural and organizational factors affect the students' acceptance and usage behaviour of the Web-based learning systems. More specifically, the proposed model extends the Technology Acceptance Model (TAM) to…
ERIC Educational Resources Information Center
Gyamfi, Stephen Adu
2016-01-01
This study extends the technology acceptance model to identify factors that influence technology acceptance among pre-service teachers in Ghana. Data from 380 usable questionnaires were tested against the research model. Utilising the extended technology acceptance model (TAM) as a research framework, the study found that: pre-service teachers'…
Peripheral post-ischemic vascular repair is impaired in a murine model of Alzheimer's disease.
Merkulova-Rainon, Tatyana; Mantsounga, Chris S; Broquères-You, Dong; Pinto, Cristina; Vilar, José; Cifuentes, Diana; Bonnin, Philippe; Kubis, Nathalie; Henrion, Daniel; Silvestre, Jean-Sébastien; Lévy, Bernard I
2018-03-07
The pathophysiology of sporadic Alzheimer's disease (AD) remains uncertain. Along with brain amyloid-β (Aβ) deposits and neurofibrillary tangles, cerebrovascular dysfunction is increasingly recognized as fundamental to the pathogenesis of AD. Using an experimental model of limb ischemia in transgenic APPPS1 mice, a model of AD (AD mice), we showed that microvascular impairment also extends to the peripheral vasculature in AD. At D70 following femoral ligation, we evidenced a significant decrease in cutaneous blood flow (- 29%, P < 0.001), collateral recruitment (- 24%, P < 0.001), capillary density (- 22%; P < 0.01) and arteriole density (- 28%; P < 0.05) in hind limbs of AD mice compared to control WT littermates. The reactivity of large arteries was not affected in AD mice, as confirmed by unaltered size, and vasoactive responses to pharmacological stimuli of the femoral artery. We identified blood as the only source of Aβ in the hind limb; thus, circulating Aβ is likely responsible for the impairment of peripheral vasculature repair mechanisms. The levels of the majority of pro-angiogenic mediators were not significantly modified in AD mice compared to WT mice, except for TGF-β1 and PlGF-2, both of which are involved in vessel stabilization and decreased in AD mice (P = 0.025 and 0.019, respectively). Importantly, endothelin-1 levels were significantly increased, while those of nitric oxide were decreased in the hind limb of AD mice (P < 0.05). Our results suggest that vascular dysfunction is a systemic disorder in AD mice. Assessment of peripheral vascular function may therefore provide additional tools for early diagnosis and management of AD.
Kelly, Scott A.; Bell, Timothy A.; Selitsky, Sara R.; Buus, Ryan J.; Hua, Kunjie; Weinstock, George M.; Garland, Theodore; Pardo-Manuel de Villena, Fernando; Pomp, Daniel
2013-01-01
Replicated artificial selection for high levels of voluntary wheel running in an outbred strain of mice favored an autosomal recessive allele whose primary phenotypic effect is a 50% reduction in hind-limb muscle mass. Within the High Runner (HR) lines of mice, the numerous pleiotropic effects (e.g., larger hearts, reduced total body mass and fat mass, longer hind-limb bones) of this hypothesized adaptive allele include functional characteristics that facilitate high levels of voluntary wheel running (e.g., doubling of mass-specific muscle aerobic capacity, increased fatigue resistance of isolated muscles, longer hind-limb bones). Previously, we created a backcross population suitable for mapping the responsible locus. We phenotypically characterized the population and mapped the Minimsc locus to a 2.6-Mb interval on MMU11, a region containing ∼100 known or predicted genes. Here, we present a novel strategy to identify the genetic variant causing the mini-muscle phenotype. Using high-density genotyping and whole-genome sequencing of key backcross individuals and HR mice with and without the mini-muscle mutation, from both recent and historical generations of the HR lines, we show that a SNP representing a C-to-T transition located in a 709-bp intron between exons 11 and 12 of the Myosin heavy polypeptide 4 (Myh4) skeletal muscle gene (position 67,244,850 on MMU11; assembly, December 2011, GRCm38/mm10; ENSMUSG00000057003) is responsible for the mini-muscle phenotype, Myh4Minimsc. Using next-generation sequencing, our approach can be extended to identify causative mutations arising in mouse inbred lines and thus offers a great avenue to overcome one of the most challenging steps in quantitative genetics. PMID:24056412
Kelly, Scott A; Bell, Timothy A; Selitsky, Sara R; Buus, Ryan J; Hua, Kunjie; Weinstock, George M; Garland, Theodore; Pardo-Manuel de Villena, Fernando; Pomp, Daniel
2013-12-01
Replicated artificial selection for high levels of voluntary wheel running in an outbred strain of mice favored an autosomal recessive allele whose primary phenotypic effect is a 50% reduction in hind-limb muscle mass. Within the High Runner (HR) lines of mice, the numerous pleiotropic effects (e.g., larger hearts, reduced total body mass and fat mass, longer hind-limb bones) of this hypothesized adaptive allele include functional characteristics that facilitate high levels of voluntary wheel running (e.g., doubling of mass-specific muscle aerobic capacity, increased fatigue resistance of isolated muscles, longer hind-limb bones). Previously, we created a backcross population suitable for mapping the responsible locus. We phenotypically characterized the population and mapped the Minimsc locus to a 2.6-Mb interval on MMU11, a region containing ∼100 known or predicted genes. Here, we present a novel strategy to identify the genetic variant causing the mini-muscle phenotype. Using high-density genotyping and whole-genome sequencing of key backcross individuals and HR mice with and without the mini-muscle mutation, from both recent and historical generations of the HR lines, we show that a SNP representing a C-to-T transition located in a 709-bp intron between exons 11 and 12 of the Myosin heavy polypeptide 4 (Myh4) skeletal muscle gene (position 67,244,850 on MMU11; assembly, December 2011, GRCm38/mm10; ENSMUSG00000057003) is responsible for the mini-muscle phenotype, Myh4(Minimsc). Using next-generation sequencing, our approach can be extended to identify causative mutations arising in mouse inbred lines and thus offers a great avenue to overcome one of the most challenging steps in quantitative genetics.
Carter, Richard T.
2017-01-01
Understandably, most locomotor analyses of bats have focused on flight mechanics and behaviors. However, we investigated nonflight locomotion in an effort to glean deeper insights into the evolutionary history of bats. We used high-speed video (300 Hz) to film and compare walking and climbing mechanics and kinematics between several species of the suborders Megachiroptera (Pteropodidae) versus Microchiroptera (Vespertilionidae and Phyllostomatidae). We found fundamentally distinctive behaviors, functional abilities, and performance outcomes between groups, but nearly homogeneous outcomes within groups. Megachiropterans exhibited climbing techniques and skills not found in microchiropterans and which aligned with other fully arboreal mammals. Megachiropterans climbed readily when placed in a head-up posture on a vertical surface, showed significantly greater ability than microchiropterans to abduct and extend the reach of their limbs, and climbed at a greater pace by using a more aggressive ipsilateral gait, at times being supported by only a single contact point. In addition, megachiropterans showed little ability to employ basic walking mechanics when placed on the ground, also a pattern observed in some highly adapted arboreal mammals. Conversely, microchiropterans resisted climbing vertical surfaces in a head-up posture, showed significantly less extension of their limbs, and employed a less-aggressive, slower contralateral gait with three points of contact. When walking, microchiropterans used the same gait they did when climbing which is representative of basic tetrapod terrestrial mechanics. Curiously, megachiropterans cycled their limbs significantly faster when climbing than when attempting to walk, whereas microchiropterans cycled their limbs at significantly faster rates when walking than when climbing. We contend that nonflight locomotion mechanics give a deep evolutionary view into the ancestral es locomotor platform on which flight was built in each of these groups. PMID:28957404
Structure and dynamics of coronal plasmas
NASA Technical Reports Server (NTRS)
Golub, Leon
1995-01-01
The Normal Incidence X-ray Telescope (NIXT) obtained a unique set of high resolution full disk solar images which were exposed simultaneously by X-rays in a passband at 63.5 A and by visible light. The perfect alignment of a photospheric visible light image with a coronal X-ray image enables us to present observations of X-ray intensity vs an accurately determined height above the visible limb. The height at which the observed X-ray intensity peak varies from 4000 km in active regions to 9000 km in quiet regions of the sun. The interpretation of the observations stems from the previously established fact that, for the coronal loops, emission in the NIXT bandpass peaks sharply just above the footpoints. Because there is not a sharp peak in the observed X-ray intensity vs off limb height, we conclude that the loop footpoints, when viewed at the limb, are obscured by absorption in chromospheric material along the line of sight. We calculate the X-ray intensity vs height predicted by a number of different idealizations of the solar atmosphere, and we compare these calculations with the observed X-ray intensity vs height. The calculations use existing coronal and chromospheric models. In order for the calculations to reproduce the observed off limb X-ray intensities, we are forced to assume an atmosphere in which the footpoints of coronal loops are interspersed along the line of sight with cooler chromospheric material extending to heights well above the loop footpoints. We argue that the absorption coefficient for NIXT X-rays by chromospheric material is roughly proportional to the neutral hydrogen density, and we estimate an average neutral hydrogen density and scale height implied by the data.
Influence of atipamezole on effects of midsacral subarachnoidally administered detomidine in mares.
Skarda, R T; Muir, W W
1998-04-01
To examine effects of atipamezole on detomidine midsacral subarachnoidally-induced analgesia, cardiovascular and respiratory activity, head ptosis, and position of pelvic limbs in healthy mares. 10 healthy mares. Using a randomized, blinded, crossover study design, mares received detomidine (0.03 mg/kg of body weight, diluted in 3 ml of CSF) midsacral subarachnoidally, followed by atipamezole (0.1 mg/kg [test]) or sterile saline (0.9% NaCl) solution (control), i.v. 61 minutes later and saline solution (3 ml, midsacral subarachnoidally) on a separate occasion, at least 2 weeks later. Analgesia was determined by lack of sensory perception to electrical stimulation at the perineal dermatome and no response to needle-prick stimulation extending from the coccygeal to T15 dermatomes. Arterial acid-base (pH, standard bicarbonate, and base excess values), gas tensions (PO2, PCO2), PCV, total solids concentration, heart and respiratory rates, rectal temperature, and arterial blood pressure were determined, and mares were observed for sweating and urination. Mean scores of perineal analgesia, head ptosis, position of pelvic limbs, and cardiovascular and respiratory data were compared for the 3-hour test period. Subarachnoidally administered detomidine induced perineal analgesia (mean +/- SD onset, 9.0 +/- 4.6 minutes; duration, 130 +/- 26 minutes), marked head ptosis, moderate changes in pelvic limb position, cardiovascular and respiratory depression, sweating in analgesic zones, and diuresis. Intravenously administered atipamezole significantly reduced mean scores of detomidine-induced perineal analgesia, head ptosis, pelvic limb position, sweating and diuresis; partially antagonized detomidine-induced bradycardia; and did not effect detomidine-induced bradypnea. Most effects of midsacral subarachnoidally administered detomidine, except bradycardia and bradypnea, were reversed by atipamezole (0.1 mg/kg, i.v.), indicating that most of the actions of detomidine were mediated via activation of alpha2-adrenergic receptors.
Upper limb post-stroke sensory impairments: the survivor's experience.
Doyle, Susan D; Bennett, Sally; Dudgeon, Brian
2014-01-01
This study described stroke survivors' experiences of upper limb post-stroke sensory impairment (ULPSSI) and its rehabilitation. A qualitative descriptive study of 15 stroke survivors with ULPSSI using semi-structured interviews. A focus group of eight survivors reviewed thematic outcomes. Analysis was completed by three authors. Three themes emerged: (1) What happened to my hand?: A description of the significant impact of sensory impairments on survivors roles and participation; (2) I was only just getting started: Survivors felt sensory impairments and the upper limb were ignored in rehabilitation and described being left on their own to devise their own rehabilitation; and (3) If I work hard then maybe someday: Survivors felt sensory impairments recovered slowly and was aided by working towards recovery and maintaining hope. Sensory impairments are significant for survivors and are deserving of greater clinical and research attention. In particular, assessments and interventions need further development and testing. This study's findings revealed the need to ascertain individual survivors' preference for involvement in decision making related to their rehabilitation planning. It also found survivors view recovery as extending well beyond current rehabilitation frameworks, necessitating further description of recovery and re-evaluation of service delivery to address survivors' needs. Sensory impairments significantly impact stroke survivors' roles and participation. Remediation of sensory impairments is important to survivors, but seems to be ignored in the rehabilitation process. Individual survivors' preference for involvement in decision making related to their rehabilitation planning should be ascertained. Stroke survivors feel left on their own to address their upper limb impairments long after rehabilitation services have ended. The development of services beyond the normal rehabilitation timeframes is warranted.
Straker, L; Pollock, C; Burgess-Limerick, R; Skoss, R; Coleman, J
2008-08-01
Computer display height and desk design are believed to be important workstation features and are included in international standards and guidelines. However, the evidence base for these guidelines is lacking a comparison of neck/shoulder muscle activity during computer and paper tasks and whether forearm support can be provided by desk design. This study measured the spinal and upper limb muscle activity in 36 young adults whilst they worked in different computer display, book and desk conditions. Display height affected spinal muscle activity with paper tasks resulting in greater mean spinal and upper limb muscle activity. A curved desk resulted in increased proximal muscle activity. There was no substantial interaction between display and desk.
Development of Quasi-3DOF upper limb rehabilitation system using ER brake: PLEMO-P1
NASA Astrophysics Data System (ADS)
Kikuchi, T.; Fukushima, K.; Furusho, J.; Ozawa, T.
2009-02-01
In recent years, many researchers have studied the potential of using robotics technology to assist and quantify the motor functions for neuron-rehabilitation. Some kinds of haptic devices have been developed and evaluated its efficiency with clinical tests, for example, upper limb training for patients with spasticity after stroke. However, almost all the devices are active-type (motor-driven) haptic devices and they basically require high-cost safety system compared to passive-type (brake-based) devices. In this study, we developed a new practical haptic device 'PLEMO-P1'; this system adopted ER brakes as its force generators. In this paper, the mechanism of PLEMO-P1 and its software for a reaching rehabilitation are described.
Barredo, Jennifer; Acluche, Frantzy; Disla, Roxanne; Fantini, Christopher; Fishelis, Leah; Sasson, Nicole; Resnik, Linda
2017-08-01
To describe a participant with scapulo-thoracic amputation and cognitive impairment trained to use the DEKA Arm and discuss factors relevant to the determination that he was not an appropriate candidate for independent home use of the device. The participant underwent 40 h of in-laboratory training with the DEKA Arm Advanced Upper Limb Prosthesis. Pre-training neuropsychological measures of cognition were collected. Qualitative and quantitative data related to functional performance, quality of life and pain were collected after 10 h of training, and at the conclusion of training. Using a constant comparative approach, data were binned into major themes; elements within each theme were identified. Six themes were relevant to the determination that the participant was inappropriate for home use of the DEKA Arm: physical and mental health; learning, memory and cognition; adult role function; functional performance; user safety and judgement and capacity for independent device use. Issues contraindicating unsupervised device use included: uncontrolled health symptoms, poor knowledge application, safety concerns, absenteeism and performance degradation under stress. The findings have implications for training with and prescription of the DEKA Arm and other complex upper limb prostheses. Further research is needed to develop a model to guide prescription of technologically complex upper limb prostheses. Implications for Rehabilitation Advanced upper limb prostheses, like the DEKA Arm, promise greater functionality, but also may be cognitively demanding, raising questions of when, and if, prescription is appropriate for patients with cognitive impairment. At this time, no formal criteria exist to guide prescription of advanced upper limb prostheses. Each clinical team applies their own informal standards in decision-making. In this case report, we described six factors that were considered in determining whether or not a research participant, with scapulo-thoracic amputation and cognitive impairment was appropriate for home use of a complex upper limb prosthesis. The findings have implications for training with and prescription of the DEKA Arm, and highlights the need for further research to develop prescription guidelines for advanced assistive devices.
Johansson, Anna-Maria; Domellöf, Erik; Rönnqvist, Louise
2012-01-01
Children with cerebral palsy (CP) require individualized long-term management to maintain and improve motor functions. The objective of this study was to explore potential effects of synchronized metronome training (SMT) on movement kinematics in two children diagnosed with spastic hemiplegic CP (HCP). Both children underwent 4-weeks/12 sessions of SMT by means of the Interactive Metronome (IM). Optoelectronic registrations of goal-directed uni- and bimanual upper-limb movements were made at three occasions; pre-training, post completed training and at 6-months post completed training. Significant changes in kinematic outcomes following IM training were found for both cases. Findings included smoother and shorter movement trajectories in the bimanual condition, especially for the affected side. In the unimanual condition, Case I also showed increased smoothness of the non-affected side. The observed short- and long-term effects on the spatio-temporal organization of upper-limb movements need to be corroborated and extended by further case-control studies.
IMPACT OF GRAVITY LOADING ON POST-STROKE REACHING AND ITS RELATIONSHIP TO WEAKNESS
Beer, Randall F.; Ellis, Michael D.; Holubar, Bradley G.; Dewald, Julius P.A.
2010-01-01
The ability to extend the elbow following stroke depends on the magnitude and direction of torques acting at the shoulder. The mechanisms underlying this link remain unclear. The purpose of this study was to evaluate whether the effects of shoulder loading on elbow function were related to weakness or its distribution in the paretic limb. Ten subjects with longstanding hemiparesis performed movements with the arm either passively supported against gravity by an air bearing, or by activation of shoulder muscles. Isometric maximum voluntary torques at the elbow and shoulder were measured using a load cell. The speed and range of elbow extension movements were negatively impacted by actively supporting the paretic limb against gravity. However, the effects of gravity loading were not related to proximal weakness or abnormalities in the elbow flexor–extensor strength balance. The findings support the existence of abnormal descending motor commands that constrain the ability of stroke survivors to generate elbow extension torque in combination with abduction torque at the shoulder. PMID:17486581
NASA Astrophysics Data System (ADS)
Lu, Shan; Zhang, Hanmo
2016-01-01
To meet the requirement of autonomous orbit determination, this paper proposes a fast curve fitting method based on earth ultraviolet features to obtain accurate earth vector direction, in order to achieve the high precision autonomous navigation. Firstly, combining the stable characters of earth ultraviolet radiance and the use of transmission model software of atmospheric radiation, the paper simulates earth ultraviolet radiation model on different time and chooses the proper observation band. Then the fast improved edge extracting method combined Sobel operator and local binary pattern (LBP) is utilized, which can both eliminate noises efficiently and extract earth ultraviolet limb features accurately. And earth's centroid locations on simulated images are estimated via the least square fitting method using part of the limb edges. Taken advantage of the estimated earth vector direction and earth distance, Extended Kalman Filter (EKF) is applied to realize the autonomous navigation finally. Experiment results indicate the proposed method can achieve a sub-pixel earth centroid location estimation and extremely enhance autonomous celestial navigation precision.
Impact of gravity loading on post-stroke reaching and its relationship to weakness.
Beer, Randall F; Ellis, Michael D; Holubar, Bradley G; Dewald, Julius P A
2007-08-01
The ability to extend the elbow following stroke depends on the magnitude and direction of torques acting at the shoulder. The mechanisms underlying this link remain unclear. The purpose of this study was to evaluate whether the effects of shoulder loading on elbow function were related to weakness or its distribution in the paretic limb. Ten subjects with longstanding hemiparesis performed movements with the arm either passively supported against gravity by an air bearing, or by activation of shoulder muscles. Isometric maximum voluntary torques at the elbow and shoulder were measured using a load cell. The speed and range of elbow extension movements were negatively impacted by actively supporting the paretic limb against gravity. However, the effects of gravity loading were not related to proximal weakness or abnormalities in the elbow flexor-extensor strength balance. The findings support the existence of abnormal descending motor commands that constrain the ability of stroke survivors to generate elbow extension torque in combination with abduction torque at the shoulder.
Towards the control of individual fingers of a prosthetic hand using surface EMG signals.
Tenore, Francesco; Ramos, Ander; Fahmy, Amir; Acharya, Soumyadipta; Etienne-Cummings, Ralph; Thakor, Nitish V
2007-01-01
The fast pace of development of upper-limb prostheses requires a paradigm shift in EMG-based controls. Traditional control schemes are only capable of providing 2 degrees of freedom, which is insufficient for dexterous control of individual fingers. We present a framework where myoelectric signals from natural hand and finger movements can be decoded with a high accuracy. 32 surface-EMG electrodes were placed on the forearm of an able-bodied subject while performing individual finger movements. Using time-domain feature extraction methods as inputs to a neural network classifier, we show that 12 individuated flexion and extension movements of the fingers can be decoded with an accuracy higher than 98%. To our knowledge, this is the first instance in which such movements have been successfully decoded using surface-EMG. These preliminary findings provide a framework that will allow the results to be extended to non-invasive control of the next generation of upper-limb prostheses for amputees.
L-alpha intensity in coronal streamers
NASA Technical Reports Server (NTRS)
Noci, G.; Poletto, G.; Suess, S. T.; Wang, A.-H.; Wu, S. T.
1993-01-01
White-light images are presently the primary source of information on physical conditions in the solar corona at distances greater than a few tenths of a solar radius above the limb. As a consequence, we still only have an incomplete description of structures extending beyond the solar limb. In particular, streamers, although observed for decades, represent a poorly known phenomenon. SOHO, to be launched in 1995, will be able to make long-term observations of these features up to heights of a few solar radii, both in white light and UV. In this paper we present simulations of L-alpha intensity in coronal streamers, based on the two-dimensional (2D) model developed by Wang et at. (1992, 1993) via a time-dependent numerical relaxation approach. Because the model is 2D, we make an a priori hypothesis about the extension of streamers in the third dimension. L-alpha data, obtained from a rocket (Kohl et al., 1983), allowed us to identify a shape which fits the observations.
Epithelioid sarcoma of the spine: case report and literature review.
Chamadoira, Clara; Pereira, Paulo; Silva, Pedro S; Castro, Ligia; Vaz, Rui
2014-01-01
Epithelioid sarcomas are rare mesenchymal neoplasms mainly arising in the limbs of young adults. We report the case of a 24-year-old male presenting low back pain radiating to both lower limbs, constipation and urinary retention. The MRI scan showed an intraspinal lesion extending from L4 to S2. Surgery resulted in gross total removal of the extradural lesion and partial removal of the intradural component. The immunohistological study of the lesion was consistent with an epithelioid sarcoma. The patient was submitted to radiotherapy and chemotherapy, but a local recurrence of the lesion and dissemination along the neuraxis were observed 3 months after surgery. Despite treatment, the patient died 4 months after the surgical procedure due to multiorgan failure. Despite there being isolated reports of epithelioid sarcomas appearing in the spine, this is, to our knowledge, the first case with intradural extension. Copyright © 2013 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
ERIC Educational Resources Information Center
Science Teacher, 2005
2005-01-01
Massachusetts Institute of Technology (MIT) mathematicians have discovered how certain insects can climb what to them are steep, slippery slopes in the water's surface without moving their limbs, and do it at high speed. Welcome to the world of the tiny creatures that live on the surface of ponds, lakes, and other standing bodies of water. For the…
NASA Astrophysics Data System (ADS)
Lanzagorta, Marco; Jitrik, Oliverio; Uhlmann, Jeffrey; Venegas-Andraca, Salvador E.
2017-05-01
In previous research we designed an interferometric quantum seismograph that uses entangled photon states to enhance sensitivity in an optomechanic device. However, a spatially-distributed array of such sensors, with each sensor measuring only nm-vibrations, may not provide sufficient sensitivity for the prediction of major earthquakes because it fails to exploit potentially critical phase information. We conjecture that relative phase information can explain the anecdotal observations that animals such as lemurs exhibit sensitivity to impending earthquakes earlier than can be done confidently with traditional seismic technology. More specifically, we propose that lemurs use their limbs as ground motion sensors and that relative phase differences are fused in the brain in a manner similar to a phased-array or synthetic-aperture radar. In this paper we will describe a lemur-inspired quantum sensor network for early warning of earthquakes. The system uses 4 interferometric quantum seismographs (e.g., analogous to a lemurs limbs) and then conducts phase and data fusion of the seismic information. Although we discuss a quantum-based technology, the principles described can also be applied to classical sensor arrays
Effects of Robot-Assisted Therapy for the Upper Limb After Stroke.
Veerbeek, Janne M; Langbroek-Amersfoort, Anneli C; van Wegen, Erwin E H; Meskers, Carel G M; Kwakkel, Gert
2017-02-01
Robot technology for poststroke rehabilitation is developing rapidly. A number of new randomized controlled trials (RCTs) have investigated the effects of robot-assisted therapy for the paretic upper limb (RT-UL). To systematically review the effects of poststroke RT-UL on measures of motor control of the paretic arm, muscle strength and tone, upper limb capacity, and basic activities of daily living (ADL) in comparison with nonrobotic treatment. Relevant RCTs were identified in electronic searches. Meta-analyses were performed for measures of motor control (eg, Fugl-Meyer Assessment of the arm; FMA arm), muscle strength and tone, upper limb capacity, and basic ADL. Subgroup analyses were applied for the number of joints involved, robot type, timing poststroke, and treatment contrast. Forty-four RCTs (N = 1362) were included. No serious adverse events were reported. Meta-analyses of 38 trials (N = 1206) showed significant but small improvements in motor control (~2 points FMA arm) and muscle strength of the paretic arm and a negative effect on muscle tone. No effects were found for upper limb capacity and basic ADL. Shoulder/elbow robotics showed small but significant effects on motor control and muscle strength, while elbow/wrist robotics had small but significant effects on motor control. RT-UL allows patients to increase the number of repetitions and hence intensity of practice poststroke, and appears to be a safe therapy. Effects on motor control are small and specific to the joints targeted by RT-UL, whereas no generalization is found to improvements in upper limb capacity. The impact of RT-UL started in the first weeks poststroke remains unclear. These limited findings could mainly be related to poor understanding of robot-induced motor learning as well as inadequate designing of RT-UL trials, by not applying an appropriate selection of stroke patients with a potential to recovery at baseline as well as the lack of fixed timing of baseline assessments and using an insufficient treatment contrast early poststroke.
Samuel, Oluwarotimi Williams; Geng, Yanjuan; Li, Xiangxin; Li, Guanglin
2017-10-28
To control multiple degrees of freedom (MDoF) upper limb prostheses, pattern recognition (PR) of electromyogram (EMG) signals has been successfully applied. This technique requires amputees to provide sufficient EMG signals to decode their limb movement intentions (LMIs). However, amputees with neuromuscular disorder/high level amputation often cannot provide sufficient EMG control signals, and thus the applicability of the EMG-PR technique is limited especially to this category of amputees. As an alternative approach, electroencephalograph (EEG) signals recorded non-invasively from the brain have been utilized to decode the LMIs of humans. However, most of the existing EEG based limb movement decoding methods primarily focus on identifying limited classes of upper limb movements. In addition, investigation on EEG feature extraction methods for the decoding of multiple classes of LMIs has rarely been considered. Therefore, 32 EEG feature extraction methods (including 12 spectral domain descriptors (SDDs) and 20 time domain descriptors (TDDs)) were used to decode multiple classes of motor imagery patterns associated with different upper limb movements based on 64-channel EEG recordings. From the obtained experimental results, the best individual TDD achieved an accuracy of 67.05 ± 3.12% as against 87.03 ± 2.26% for the best SDD. By applying a linear feature combination technique, an optimal set of combined TDDs recorded an average accuracy of 90.68% while that of the SDDs achieved an accuracy of 99.55% which were significantly higher than those of the individual TDD and SDD at p < 0.05. Our findings suggest that optimal feature set combination would yield a relatively high decoding accuracy that may improve the clinical robustness of MDoF neuroprosthesis. The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.
Recent trends in assistive technology for mobility
2012-01-01
Loss of physical mobility makes maximal participation in desired activities more difficult and in the worst case fully prevents participation. This paper surveys recent work in assistive technology to improve mobility for persons with a disability, drawing on examples observed during a tour of academic and industrial research sites in Europe. The underlying theme of this recent work is a more seamless integration of the capabilities of the user and the assistive technology. This improved integration spans diverse technologies, including powered wheelchairs, prosthetic limbs, functional electrical stimulation, and wearable exoskeletons. Improved integration is being accomplished in three ways: 1) improving the assistive technology mechanics; 2) improving the user-technology physical interface; and 3) sharing of control between the user and the technology. We provide an overview of these improvements in user-technology integration and discuss whether such improvements have the potential to be transformative for people with mobility impairments. PMID:22520500
Three-dimensional computer-aided human factors engineering analysis of a grafting robot.
Chiu, Y C; Chen, S; Wu, G J; Lin, Y H
2012-07-01
The objective of this research was to conduct a human factors engineering analysis of a grafting robot design using computer-aided 3D simulation technology. A prototype tubing-type grafting robot for fruits and vegetables was the subject of a series of case studies. To facilitate the incorporation of human models into the operating environment of the grafting robot, I-DEAS graphic software was applied to establish individual models of the grafting robot in line with Jack ergonomic analysis. Six human models (95th percentile, 50th percentile, and 5th percentile by height for both males and females) were employed to simulate the operating conditions and working postures in a real operating environment. The lower back and upper limb stresses of the operators were analyzed using the lower back analysis (LBA) and rapid upper limb assessment (RULA) functions in Jack. The experimental results showed that if a leg space is introduced under the robot, the operator can sit closer to the robot, which reduces the operator's level of lower back and upper limbs stress. The proper environmental layout for Taiwanese operators for minimum levels of lower back and upper limb stress are to set the grafting operation at 23.2 cm away from the operator at a height of 85 cm and with 45 cm between the rootstock and scion units.
Teachers and Technology: Development of an Extended Theory of Planned Behavior
ERIC Educational Resources Information Center
Teo, Timothy; Zhou, Mingming; Noyes, Jan
2016-01-01
This study tests the validity of an extended theory of planned behaviour (TPB) to explain teachers' intention to use technology for teaching and learning. Five hundred and ninety two participants completed a survey questionnaire measuring their responses to eight constructs which form an extended TPB. Using structural equation modelling, the…
ARBOOK: Development and Assessment of a Tool Based on Augmented Reality for Anatomy
NASA Astrophysics Data System (ADS)
Ferrer-Torregrosa, J.; Torralba, J.; Jimenez, M. A.; García, S.; Barcia, J. M.
2015-02-01
The evolution of technologies and the development of new tools with educational purposes are growing up. This work presents the experience of a new tool based on augmented reality (AR) focusing on the anatomy of the lower limb. ARBOOK was constructed and developed based on TC and MRN images, dissections and drawings. For ARBOOK evaluation, a specific questionnaire of three blocks was performed and validated according to the Delphi method. The questionnaire included motivation and attention tasks, autonomous work and three-dimensional interpretation tasks. A total of 211 students from 7 public and private Spanish universities were divided in two groups. Control group received standard teaching sessions supported by books, and video. The ARBOOK group received the same standard sessions but additionally used the ARBOOK tool. At the end of the training, a written test on lower limb anatomy was done by students. Statistically significant better scorings for the ARBOOK group were found on attention-motivation, autonomous work and three-dimensional comprehension tasks. Additionally, significantly better scoring was obtained by the ARBOOK group in the written test. The results strongly suggest that the use of AR is suitable for anatomical purposes. Concretely, the results indicate how this technology is helpful for student motivation, autonomous work or spatial interpretation. The use of this type of technologies must be taken into account even more at the present moment, when new technologies are naturally incorporated to our current lives.
Lower limb joint kinetics and ankle joint stiffness in the sprint start push-off.
Charalambous, Laura; Irwin, Gareth; Bezodis, Ian N; Kerwin, David
2012-01-01
Sprint push-off technique is fundamental to sprint performance and joint stiffness has been identified as a performance-related variable during dynamic movements. However, joint stiffness for the push-off and its relationship with performance (times and velocities) has not been reported. The aim of this study was to quantify and explain lower limb net joint moments and mechanical powers, and ankle stiffness during the first stance phase of the push-off. One elite sprinter performed 10 maximal sprint starts. An automatic motion analysis system (CODA, 200 Hz) with synchronized force plates (Kistler, 1000 Hz) collected kinematic profiles at the hip, knee, and ankle and ground reaction forces, providing input for inverse dynamics analyses. The lower-limb joints predominately extended and revealed a proximal-to-distal sequential pattern of maximal extensor angular velocity and positive power production. Pearson correlations revealed relationships (P < 0.05) between ankle stiffness (5.93 ± 0.75 N x m x deg(-1)) and selected performance variables. Relationships between negative power phase ankle stiffness and horizontal (r = -0.79) and vertical (r = 0.74) centre of mass velocities were opposite in direction to the positive power phase ankle stiffness (horizontal: r = 0.85; vertical: r = -0.54). Thus ankle stiffness may affect the goals of the sprint push-off in different ways, depending on the phase of stance considered.
Diers, Martin; Kamping, Sandra; Kirsch, Pinar; Rance, Mariela; Bekrater-Bodmann, Robin; Foell, Jens; Trojan, Joerg; Fuchs, Xaver; Bach, Felix; Maaß, Heiko; Cakmak, Hüseyin; Flor, Herta
2015-01-12
Extended viewing of movements of one's intact limb in a mirror as well as motor imagery have been shown to decrease pain in persons with phantom limb pain or complex regional pain syndrome and to increase the movement ability in hemiparesis following stroke. In addition, mirrored movements differentially activate sensorimotor cortex in amputees with and without phantom limb pain. However, using a so-called mirror box has technical limitations, some of which can be overcome by virtual reality applications. We developed a virtual reality mirror box application and evaluated its comparability to a classical mirror box setup. We applied both paradigms to 20 healthy controls and analyzed vividness and authenticity of the illusion as well as brain activation patterns. In both conditions, subjects reported similar intensities for the sensation that movements of the virtual left hand felt as if they were executed by their own left hand. We found activation in the primary sensorimotor cortex contralateral to the actual movement, with stronger activation for the virtual reality 'mirror box' compared to the classical mirror box condition, as well as activation in the primary sensorimotor cortex contralateral to the mirrored/virtual movement. We conclude that a virtual reality application of the mirror box is viable and that it might be useful for future research. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
García Juan, David; Delattre, Bénédicte M. A.; Trombella, Sara; Lynch, Sean; Becker, Matthias; Choi, Hon Fai; Ratib, Osman
2014-03-01
Musculoskeletal disorders (MSD) are becoming a big healthcare economical burden in developed countries with aging population. Classical methods like biopsy or EMG used in clinical practice for muscle assessment are invasive and not accurately sufficient for measurement of impairments of muscular performance. Non-invasive imaging techniques can nowadays provide effective alternatives for static and dynamic assessment of muscle function. In this paper we present work aimed toward the development of a generic data structure for handling n-dimensional metabolic and anatomical data acquired from hybrid PET/MR scanners. Special static and dynamic protocols were developed for assessment of physical and functional images of individual muscles of the lower limb. In an initial stage of the project a manual segmentation of selected muscles was performed on high-resolution 3D static images and subsequently interpolated to full dynamic set of contours from selected 2D dynamic images across different levels of the leg. This results in a full set of 4D data of lower limb muscles at rest and during exercise. These data can further be extended to a 5D data by adding metabolic data obtained from PET images. Our data structure and corresponding image processing extension allows for better evaluation of large volumes of multidimensional imaging data that are acquired and processed to generate dynamic models of the moving lower limb and its muscular function.
NASA Astrophysics Data System (ADS)
Drossart, P.; Combes, M.; Encrenaz, T.; Melchiorri, R.; Fouchet, T.; Forget, F.; Moroz, V.; Ignatiev, N.; Bibring, J.-P.; Langevin, Y.; OMEGA Team
Observations of Mars by the OMEGA/Mars Express experiment provide extended maps of the martian disk at all latitudes, and with various conditions of illumination, between 0.4 to 5 micron. The atmospheric investigations so far conducted by our team are focussed on the infrared part of the spectrum (1-5 micron), and include: the development of a correction algorithm for atmospheric gaseous absorption, to give access to fine mineralogic studies, largely decorrelated from atmospheric effects the study of dust opacity effects in the near infrared, with the aim to correct also the rough spectra from dust opacity perturbation the study of minor constituents like CO, to search for regional or global variations the study of CO2 emission at 4.3 micron related to fluorescent emission This last effect is prominently detected in limb observations obtained in 3-axis stabilized mode of Mars Express, with high altitude emission in the CO2 fundamental at 4.3 micron, usually seen in absorption in nadir observations. These emissions are related to non-LTE atmospheric layers, well above the solid surface in the mesosphere. Such emissions are also present in Earth and Venus limb observations. They are present also in nadir observations, but are reinforced in limb viewing geometry due to the tangential view. A numerical model of these emission will be presented.
A biodynamic feedthrough model based on neuromuscular principles.
Venrooij, Joost; Abbink, David A; Mulder, Mark; van Paassen, Marinus M; Mulder, Max; van der Helm, Frans C T; Bulthoff, Heinrich H
2014-07-01
A biodynamic feedthrough (BDFT) model is proposed that describes how vehicle accelerations feed through the human body, causing involuntary limb motions and so involuntary control inputs. BDFT dynamics strongly depend on limb dynamics, which can vary between persons (between-subject variability), but also within one person over time, e.g., due to the control task performed (within-subject variability). The proposed BDFT model is based on physical neuromuscular principles and is derived from an established admittance model-describing limb dynamics-which was extended to include control device dynamics and account for acceleration effects. The resulting BDFT model serves primarily the purpose of increasing the understanding of the relationship between neuromuscular admittance and biodynamic feedthrough. An added advantage of the proposed model is that its parameters can be estimated using a two-stage approach, making the parameter estimation more robust, as the procedure is largely based on the well documented procedure required for the admittance model. To estimate the parameter values of the BDFT model, data are used from an experiment in which both neuromuscular admittance and biodynamic feedthrough are measured. The quality of the BDFT model is evaluated in the frequency and time domain. Results provide strong evidence that the BDFT model and the proposed method of parameter estimation put forward in this paper allows for accurate BDFT modeling across different subjects (accounting for between-subject variability) and across control tasks (accounting for within-subject variability).
Augmenting forearm crutches with wireless sensors for lower limb rehabilitation
NASA Astrophysics Data System (ADS)
Merrett, Geoff V.; Ettabib, Mohamed A.; Peters, Christian; Hallett, Georgina; White, Neil M.
2010-12-01
Forearm crutches are frequently used in the rehabilitation of an injury to the lower limb. The recovery rate is improved if the patient correctly applies a certain fraction of their body weight (specified by a clinician) through the axis of the crutch, referred to as partial weight bearing (PWB). Incorrect weight bearing has been shown to result in an extended recovery period or even cause further damage to the limb. There is currently no minimally invasive tool for long-term monitoring of a patient's PWB in a home environment. This paper describes the research and development of an instrumented forearm crutch that has been developed to wirelessly and autonomously monitor a patient's weight bearing over the full period of their recovery, including its potential use in a home environment. A pair of standard forearm crutches are augmented with low-cost off-the-shelf wireless sensor nodes and electronic components to provide indicative measurements of the applied weight, crutch tilt and hand position on the grip. Data are wirelessly transmitted between crutches and to a remote computer (where they are processed and visualized in LabVIEW), and the patient receives biofeedback by means of an audible signal when they put too much or too little weight through the crutch. The initial results obtained highlight the capability of the instrumented crutch to support physiotherapists and patients in monitoring usage.
Calcium Balance in Mature Rats Exposed to a Space Flight Model
NASA Technical Reports Server (NTRS)
Wolinsky, Ira
1996-01-01
Negative calcium balances are seen in humans during spaceflight and bed rest, an analog of space flight. Due to the infrequency and costliness of space flight and the difficulties, cost, and restraints in using invasive procedures in bed rest studies, several ground based animal models of space flight have been employed. The most useful and well developed of these models is hind limb unloading in the rat. In this model the hind limbs are non-weight bearing (unloaded) but still mobile; there is a cephalad fluid shift similar to that seen in astronauts in flight; the animals are able to feed, groom and locomote using their front limbs; the procedure is reversible; and, importantly, the model has been validated by comparison to space flight. Several laboratories have studied calcium balance using rats in hind limb unweighting. Roer and Dillaman used young male rats to study calcium balance in this model for 25 days. They found no differences in dietary calcium intake, percent calcium absorption, urinary and fecal excretion, hence indicating no differences in calcium balance between control and unloaded rats. In another study, employing 120 day old females, rats' hind limbs were unloaded for 28 days. While negative calcium balances were observed during a 25 day recovery period no balance measurements were possible during unweighting since the researchers did not employ appropriate metabolic cages. In a recent study from this laboratory, using 200 g rats in the space flight model for two weeks, we found depressed intestinal calcium absorption and increased fecal calcium excretion (indicating less positive calcium balances) and lower circulating 1,25-dihydroxyvitamin D. The above studies indicate that there remains a dearth of information on calcium balance during the hind limb unloading rat space flight model, especially in mature rats, whose use is a better model for planned manned space flight than juvenile or growing animals. With the aid of a newly designed metabolic cage developed in our laboratory it is now possible to accurately measure urinary and fecal calcium excretions in this space flight model. The purpose of this study, then, was to extend and enlarge our previous findings viz: to measure calcium balances in mature rats exposed to a space flight model.
Feng, Jun-Tao; Liu, Han-Qiu; Hua, Xu-Yun; Gu, Yu-Dong; Xu, Jian-Guang; Xu, Wen-Dong
2016-12-01
Brachial plexus injury (BPI) is a type of severe peripheral nerve trauma that leads to central remodeling in the brain, as revealed by functional MRI analysis. However, previously reported remodeling is mostly restricted to sensorimotor areas of the brain. Whether this disturbance in the sensorimotor network leads to larger-scale functional remodeling remains unknown. We sought to explore the higher-level brain functional abnormality pattern of BPI patients from a large-scale network function connectivity dimension in 15 right-handed BPI patients. Resting-state functional MRI data were collected and analyzed using independent component analysis methods. Five components of interest were recognized and compared between patients and healthy subjects. Patients showed significantly altered brain local functional activities in the bilateral fronto-parietal network (FPN), sensorimotor network (SMN), and executive-control network (ECN) compared with healthy subjects. Moreover, functional connectivity between SMN and ECN were significantly less in patients compared with healthy subjects, and connectivity strength between ECN and SMN was negatively correlated with patients' residual function of the affected limb. Functional connectivity between SMN and right FPN were also significantly less than in controls, although connectivity between ECN and default mode network (DMN) was greater than in controls. These data suggested that brain functional disturbance in BPI patients extends beyond the sensorimotor network and cascades serial remodeling in the brain, which significantly correlates with residual hand function of the paralyzed limb. Furthermore, functional remodeling in these higher-level functional networks may lead to cognitive alterations in complex tasks.
Video and Computer Technologies for Extended-Campus Programming.
ERIC Educational Resources Information Center
Sagan, Edgar L.; And Others
This paper discusses video and computer technologies for extended-campus programming (courses and programs at off-campus sites). The first section provides an overview of the distance education program at the University of Kentucky (UK), and highlights the improved access to graduate and professional programs, advances in technology, funding,…
Evaluation of Extended-Wear Hearing Technology for Children with Hearing Loss.
Wolfe, Jace; Schafer, Erin; Martella, Natalie; Morais, Mila; Mann, Misty
2015-01-01
Research shows that many older children and teenagers who have mild to moderately severe sensorineural hearing loss do not use their hearing instruments during all waking hours. A variety of reasons may contribute toward this problem, including concerns about cosmetics associated with hearing aid use and the inconvenience of daily maintenance associated with hearing instruments. Extended-wear hearing instruments are inserted into the wearer's ear canal by an audiologist and are essentially invisible to outside observers. The goal of this study was to evaluate the potential benefits and limitations associated with use of extended-wear hearing instruments in a group of children with hearing loss. A two-way repeated measures design was used to examine performance differences obtained with the participants' daily-wear hearing instruments versus that obtained with extended-wear hearing instruments. Sixteen children, ages 10-17 yr old, with sensorineural hearing loss ranging from mild to moderately severe. Probe microphone measures were completed to evaluate the aided output of device. Behavioral test measures included word recognition in quiet, sentence recognition in noise, aided warble-tone thresholds, and psychophysical loudness scaling. Questionnaires were also administered to evaluate subjective performance with each hearing technology. Data logging suggested that many participants were not using their daily-wear hearing instruments during all waking hours (mean use was less than 6 h/day). Real ear probe microphone measurements indicated that a closer fit to the Desired Sensation Level Version 5 prescriptive targets was achieved with the children's daily-wear instruments when compared to the extended-wear instruments. There was no statistically significant difference in monosyllabic word recognition at 50 or 60 dBA obtained with the two hearing technologies. Sentence recognition in noise obtained with use of the extended-wear devices was, however, significantly better than what was obtained with the daily-wear hearing aids. Aided warble-tone thresholds indicated significantly better audibility for low-level sounds with use of the daily-wear hearing technology, but loudness scaling results produced mixed results. Specifically, the participants generally reported greater loudness perception with use of their daily-wear hearing aids at 2000 Hz, but use of the extended-wear hearing technology provided greater loudness perception at 4000 Hz. Finally, the participants reported higher levels of subjective performance with use of the extended-wear hearing instruments. Although some measures suggested that daily-wear hearing instruments provided better audibility than the extended-wear hearing devices, word recognition in quiet was similar with use of the two technologies, and sentence recognition in noise was better with the extended-wear hearing technology. In addition, the participants in this study reported better subjective benefit associated with the use of extended-wear hearing technology. Collectively, the results of this study suggest that extended-wear hearing technology is a viable option for older children and teenagers with mild to moderately severe hearing loss. American Academy of Audiology.
A Novel Approach For Ankle Foot Orthosis Developed By Three Dimensional Technologies
NASA Astrophysics Data System (ADS)
Belokar, R. M.; Banga, H. K.; Kumar, R.
2017-12-01
This study presents a novel approach for testing mechanical properties of medical orthosis developed by three dimensional (3D) technologies. A hand-held type 3D laser scanner is used for generating 3D mesh geometry directly from patient’s limb. Subsequently 3D printable orthotic design is produced from crude input model by means of Computer Aided Design (CAD) software. Fused Deposition Modelling (FDM) method in Additive Manufacturing (AM) technologies is used to fabricate the 3D printable Ankle Foot Orthosis (AFO) prototype in order to test the mechanical properties on printout. According to test results, printed Acrylonitrile Butadiene Styrene (ABS) AFO prototype has sufficient elasticity modulus and durability for patient-specific medical device manufactured by the 3D technologies.
Extending Learning Communities: New Technologies, Multiple Literacies, and Culture Blind Pedagogies
ERIC Educational Resources Information Center
Knight, Michelle G.; Dixon, Iris R.; Norton, Nadjwa E. L.; Bentley, Courtney
2004-01-01
Technologies such as videoconferencing used for distance education are creating ways for high schools to extend their learning communities to connect youth with professional communities of practice in ways that approximate the face-to-face interactions in traditional classrooms. These technologies are often touted as a way to augment course…
Invariance of an Extended Technology Acceptance Model Across Gender and Age Group
ERIC Educational Resources Information Center
Ahmad, Tunku Badariah Tunku; Madarsha, Kamal Basha; Zainuddin, Ahmad Marzuki; Ismail, Nik Ahmad Hisham; Khairani, Ahmad Zamri; Nordin, Mohamad Sahari
2011-01-01
In this study, we examined the likelihood of a TAME (extended technology acceptance model), in which the interrelationships among computer self-efficacy, perceived usefulness, intention to use and self-reported use of computer-mediated technology were tested. In addition, the gender- and age-invariant of its causal structure were evaluated. The…
Evaluation of an omental pedicle extension technique in the dog.
Ross, W E; Pardo, A D
1993-01-01
A two-step omental pedicle extension technique was performed on 10 dogs. Step 1 of the pedicle extension involved release of the dorsal leaf of the omentum from its pancreatic attachment, whereas step 2 consisted of an inverse L-shaped incision to double the length of the pedicle. The pedicle dimensions were measured and the distance reached when extended toward the hind limb, forelimb, and the muzzle recorded after each stage of the procedure. The vascular patency of the pedicle was determined by intravenous injection of fluorescein dye after the second stage of omental extension. Mean pedicle lengths were 44.5 cm with the first stage of extension and 82.0 cm after full extension. The mean width at the caudal extent of the pedicles after dorsal and full extension was 30.4 cm and 17.2 cm, respectively. Eight of the 10 pedicles were patent after full extension. The fully extended omental pedicles reached and, in most cases, extended beyond the distal extremities and the muzzle. The findings in this study suggest that the canine omentum can be extended to any part of the body without being detached from its vascular supply.
Stress and Displacement Analysis of Microreactors during Thermal and Vacuum Loading
2017-09-07
and extend the available energy density well beyond state-of-the-art battery technology (140 W·h/kg for rechargeable lithium [Li]- ion technology).1...time. In the 10–100 W+ power range, battery technology is the best solution currently available, but higher-energy dense technologies are needed to...augment batteries and extend the available energy density well beyond state-of-the-art battery technology. One way to approach this is to take
["Bionic" arm prostheses. State of the art in research and development].
Pylatiuk, C; Döderlein, L
2006-11-01
A new generation of arm prostheses is being developed worldwide. These so-called bionic prostheses are intended to offer additional functions, such as sensory feedback, extended range of possible movement, intuitive movement control as far as possible, and a more natural cosmetic appearance. In recent years, prosthetic components with much enhanced performance have been developed for use at various levels of the upper limb. Artificial hands that allow for additional grips are are being tested in clinical settings. Innovative methods of signal acquisition and communication with the patient are being intensively researched. Several patients have been provided with prototypes of new arm prostheses. At the moment, the results are limited by the restricted communication between patient and prosthesis. However, we can expect the options for prosthesis control to be extended in the near future.
Robotic upper limb rehabilitation after acute stroke by NeReBot: evaluation of treatment costs.
Stefano, Masiero; Patrizia, Poli; Mario, Armani; Ferlini, Gregorio; Rizzello, Roberto; Rosati, Giulio
2014-01-01
Stroke is the first cause of disability. Several robotic devices have been developed for stroke rehabilitation. Robot therapy by NeReBot is demonstrated to be an effective tool for the treatment of poststroke paretic upper limbs, able to improve the activities of daily living of stroke survivors when used both as additional treatment and in partial substitution of conventional rehabilitation therapy in the acute and subacute phases poststroke. This study presents the evaluation of the costs related to delivering such therapy, in comparison with conventional rehabilitation treatment. By comparing several NeReBot treatment protocols, made of different combinations of robotic and nonrobotic exercises, we show that robotic technology can be a valuable and economically sustainable aid in the management of poststroke patient rehabilitation.
A Heads-Up Display for Diabetic Limb Salvage Surgery
Rankin, Timothy M.; Giovinco, Nicholas A.; Mills, Joseph L.; Matsuoka, Yoky
2014-01-01
Although the use of augmented reality has been well described over the past several years, available devices suffer from high cost, an uncomfortable form factor, suboptimal battery life, and lack an app-based developer ecosystem. This article describes the potential use of a novel, consumer-based, wearable device to assist surgeons in real time during limb preservation surgery and clinical consultation. Using routine intraoperative, clinical, and educational case examples, we describe the use of a wearable augmented reality device (Google Glass; Google, Mountain View, CA). The device facilitated hands-free, rapid communication, documentation, and consultation. An eyeglass-mounted screen form factor has the potential to improve communication, safety, and efficiency of intraoperative and clinical care. We believe this represents a natural progression toward union of medical devices with consumer technology. PMID:24876445
Contractile function and motor unit firing rates of the human hamstrings.
Kirk, Eric A; Rice, Charles L
2017-01-01
Neuromuscular properties of the lower limb in health, aging, and disease are well described for major lower limb muscles comprising the quadriceps, triceps surae, and dorsiflexors, with the notable exception of the posterior thigh (hamstrings). The purpose of this study was to further characterize major muscles of the lower limb by comprehensively exploring contractile properties in relation to spinal motor neuron output expressed as motor unit firing rates (MUFRs) in the hamstrings of 11 (26.5 ± 3.8) young men. Maximal isometric voluntary contraction (MVC), voluntary activation, stimulated contractile properties including a force-frequency relationship, and MUFRs from submaximal to maximal voluntary contractile intensities were assessed in the hamstrings. Strength and MUFRs were assessed at two presumably different muscle lengths by varying the knee joint angles (90° and 160°). Knee flexion MVCs were 60-70% greater in the extended position (160°). The frequency required to elicit 50% of maximum tetanic torque was 16-17 Hz. Mean MUFRs at 25-50% MVC were 9-31% less in the biceps femoris compared with the semimembranosus-semitendinosus group. Knee joint angle (muscle length) influenced MUFRs such that mean MUFRs were greater in the shortened (90°) position at 50% and 100% MVC. Compared with previous reports, mean maximal MUFRs in the hamstrings are greater than those in the quadriceps and triceps surae and somewhat less than those in the tibialis anterior. Mean maximal MUFRs in the hamstrings are influenced by changes in knee joint angle, with lower firing rates in the biceps femoris compared with the semimembranosus-semitendinosus muscle group. We studied motor unit firing rates (MUFRs) at various voluntary contraction intensities in the hamstrings, one of the only major lower limb muscles to have MUFRs affected by muscle length changes. Within the hamstrings muscle-specific differences have greater impact on MUFRs than length changes, with the biceps femoris having reduced neural drive compared with the semimembranosus-semimembranosus. Comparing our results to other lower limb muscles, flexors have inherently higher firing rate compared with extensors. Copyright © 2017 the American Physiological Society.
Contractile function and motor unit firing rates of the human hamstrings
Kirk, Eric A.
2016-01-01
Neuromuscular properties of the lower limb in health, aging, and disease are well described for major lower limb muscles comprising the quadriceps, triceps surae, and dorsiflexors, with the notable exception of the posterior thigh (hamstrings). The purpose of this study was to further characterize major muscles of the lower limb by comprehensively exploring contractile properties in relation to spinal motor neuron output expressed as motor unit firing rates (MUFRs) in the hamstrings of 11 (26.5 ± 3.8) young men. Maximal isometric voluntary contraction (MVC), voluntary activation, stimulated contractile properties including a force-frequency relationship, and MUFRs from submaximal to maximal voluntary contractile intensities were assessed in the hamstrings. Strength and MUFRs were assessed at two presumably different muscle lengths by varying the knee joint angles (90° and 160°). Knee flexion MVCs were 60–70% greater in the extended position (160°). The frequency required to elicit 50% of maximum tetanic torque was 16–17 Hz. Mean MUFRs at 25–50% MVC were 9–31% less in the biceps femoris compared with the semimembranosus-semitendinosus group. Knee joint angle (muscle length) influenced MUFRs such that mean MUFRs were greater in the shortened (90°) position at 50% and 100% MVC. Compared with previous reports, mean maximal MUFRs in the hamstrings are greater than those in the quadriceps and triceps surae and somewhat less than those in the tibialis anterior. Mean maximal MUFRs in the hamstrings are influenced by changes in knee joint angle, with lower firing rates in the biceps femoris compared with the semimembranosus-semitendinosus muscle group. NEW & NOTEWORTHY We studied motor unit firing rates (MUFRs) at various voluntary contraction intensities in the hamstrings, one of the only major lower limb muscles to have MUFRs affected by muscle length changes. Within the hamstrings muscle-specific differences have greater impact on MUFRs than length changes, with the biceps femoris having reduced neural drive compared with the semimembranosus-semimembranosus. Comparing our results to other lower limb muscles, flexors have inherently higher firing rate compared with extensors. PMID:27784806
ERIC Educational Resources Information Center
Akman, Ibrahim; Turhan, Cigdem
2017-01-01
This study aims to explore the users' behaviour and acceptance of social media for learning in higher educational institutions with the help of the extended Technology Acceptance Model (TAM). TAM has been extended to investigate how ethical and security awareness of users affect the actual usage of social learning applications. For this purpose, a…
Kashiwagi, Maki; Chaoui, Rabih; Stallmach, Thomas; Hürlimann, Sandra; Lauper, Urs; Hebisch, Gundula
2003-11-01
Maternal cocaine abuse in pregnancy is associated with complications such as intrauterine growth retardation, abruptio placentae, and preterm delivery. We report what is, to our knowledge, the first published observation of fetal bilateral renal agenesis associated with a vascular disruption syndrome comprising upper limb reduction defect and a single umbilical artery following maternal cocaine abuse in early pregnancy. This constellation in a fetus aborted at 18 weeks extends the spectrum of complications possibly associated with cocaine abuse in pregnancy. Copyright 2003 Wiley-Liss, Inc.
The spinal cord: a review of functional neuroanatomy.
Bican, Orhan; Minagar, Alireza; Pruitt, Amy A
2013-02-01
The spinal cord controls the voluntary muscles of the trunk and limbs and receives sensory input from these areas. It extends from the medulla oblongata to the lower border of the first lumbar vertebra. A basic knowledge of spinal cord anatomy is essential for interpretation of clinical signs and symptoms and for understanding of pathologic processes involving the spinal cord. In this article, anatomic structures are correlated with relevant clinical signs and symptoms and a step-wise approach to spinal cord diagnosis is outlined. Copyright © 2013 Elsevier Inc. All rights reserved.
1981-08-23
Range : 2.3 million km. ( 1.4 million miles ) P-24067C This Voyager 2 photograph of Titan, a satellite of Saturn, shows some detail in the cloud systems. The southern hemisphere appears lighter in contrast, a well defined band is seen near the equator, and a dark collar is evident at the north pole. All these bands are associated with the cloud circulation in titan's atmosphere. The extended haze, composed of of sub-micron size particles, is seen clearly around the satellite's limb. This image was composed from blue, green, and violet frames.
Microsurgical resection of cavernous haemangioma around the thoracic neuroforamen: a case report.
Uchida, Kenzo; Yayama, Takafumi; Nakajima, Hideaki; Hirai, Takayuki; Kobayashi, Shigeru; Chen, Kebing; Guerrero, Alexander Rodriguez; Baba, Hisatoshi
2010-12-01
Treatment for haemangioma of the spinal cord often results in extensive bony resection that necessitates fusion and/or instrumentation. We report on a 75-year-old man who presented with neuropathic pain and muscle weakness of both lower limbs, secondary to an epidural haemangioma at T11-T12, extending laterally into the neuroforamen. The tumour was resected within the neuroforamen after a partial laminectomy and limited medial foraminotomy at T11-T12, without disruption of the osseous continuity of the pars interarticularis, avoiding spinal stabilisation surgery.
Kanyi, John; Karwa, Rakhi; Pastakia, Sonak Dinesh; Manji, Imran; Manyara, Simon; Saina, Collins
2017-05-01
HIV-infected patients are at an increased risk of developing venous thromboembolism (VTE), and minimal data are available to describe the need for extended treatment. To evaluate the frequency of and determine predictive risk factors for extended anticoagulation of VTE in HIV-infected patients in rural, western Kenya. A retrospective chart review was conducted at the Anticoagulation Monitoring Service affiliated with Moi Teaching and Referral Hospital and the Academic Model Providing Access to Healthcare. Data were collected on patients who were HIV-infected and receiving anticoagulation for lower-limb deep vein thrombosis. The need for extended anticoagulation, defined as receiving ≥7 months of warfarin therapy, was established based on patient symptoms or Doppler ultrasound-confirmed diagnosis. Evaluation of the secondary outcomes utilized a univariate analysis to identify risk factors associated with extended anticoagulation. A total of 71 patients were included in the analysis; 27 patients (38%) required extended anticoagulation. The univariate analysis showed a statistically significant association between the need for extended anticoagulation and achieving a therapeutic international normalized ratio within 21 days in both the unadjusted and adjusted analysis. Patients with a history of opportunistic infections required an extended duration of anticoagulation in the adjusted analysis: odds ratio = 3.42; 95% CI = 1.04-11.32; P = 0.04. This study shows that there may be a need for increased duration of anticoagulation in HIV-infected patients, with a need to address the issue of long-term management. Guideline recommendations are needed to address the complexity of treatment issues in this population.
Preston, Nick; Weightman, Andrew; Gallagher, Justin; Holt, Raymond; Clarke, Michael; Mon-Williams, Mark; Levesley, Martin; Bhakta, Bipinchandra
2016-01-01
We investigated the feasibility of using computer-assisted arm rehabilitation (CAAR) computer games in schools. Outcomes were children's preference for single player or dual player mode, and changes in arm activity and kinematics. Nine boys and two girls with cerebral palsy (6-12 years, mean 9 years) played assistive technology computer games in single-user mode or with school friends in an AB-BA design. Preference was determined by recording the time spent playing each mode and by qualitative feedback. We used the ABILHAND-kids and Canadian Occupational Performance Measure to evaluate activity limitation, and a portable laptop-based device to capture arm kinematics. No difference was recorded between single-user and dual-user modes (median daily use 9.27 versus 11.2 min, p = 0.214). Children reported dual-user mode was preferable. There were no changes in activity limitation (ABILHAND-kids, p = 0.424; COPM, p = 0.484) but we found significant improvements in hand speed (p = 0.028), smoothness (p = 0.005) and accuracy (p = 0.007). School timetables prohibit extensive use of rehabilitation technology but there is potential for its short-term use to supplement a rehabilitation program. The restricted access to the rehabilitation games was sufficient to improve arm kinematics but not arm activity. Implications for Rehabilitation School premises and teaching staff present no obstacles to the installation of rehabilitation gaming technology. Twelve minutes per day is the average amount of time that the school time table permits children to use rehabilitation gaming equipment (without disruption to academic attendance). The use of rehabilitation gaming technology for an average of 12 minutes daily does not appear to benefit children's functional performance, but there are improvements in the kinematics of children's upper limb.
ERIC Educational Resources Information Center
Teo, Timothy
2010-01-01
This study examined pre-service teachers' self-reported behavioral intentions to use technology. Three hundred and fourteen participants completed a survey questionnaire measuring their responses to six constructs from a research model that extends the technology acceptance model (TAM) by including facilitating conditions and subjective norm.…
K, Kandhari V; M, Desai M; S, Bava S; N, Wade R
2015-01-01
Chances of avascular necrosis of acetabulum are rare as it enjoys a rich blood supply. But cases of post - traumatic avascular necrosis of acetabulum following fracture of posterior column have been well documented. Importance of identifying and suspecting the avascular necrosis of acetabulum is essential in cases of failed fixation of fracture acetabulum, previously operated using extensile approach to acetabulum; either extended anterior ilio - femoral or tri - radiate approach. Such patients usually present with repeated deep bone infection or with early failure of fixation with aseptic loosening and migration of its components. We present a similar case. 40 years female presented with inadequately managed transverse fracture of left acetabulum done by anterior extended ilio-inguinal approach. The fixation failed. She presented 6 months later with painful hip. Cemented total hip replacement was performed with reconstruction of acetabulum by posterior column plating. Six months postoperatively patient presented with dislodgement of cup, pelvic discontinuity and sinus in the thigh. Two stage revision surgery was planned. First implant, removal; debridement and antibiotic spacer surgery was performed. At second stage of revision total hip replacement, patient had Paprosky grade IIIb defect in acetabulum. Spacer was removed through the posterior approach. Anterior approach was taken for anterior plating. Intra-operatively external iliac pulsations were found to be absent so procedure was abandoned after expert opinion. Postoperatively digital subtraction angiography demonstrated a chronic block in the external iliac artery and corona mortis was the only patent vascular channel providing vascular to the left lower limb. Thus, peripheral limb was stealing blood supply from the acetabulum to maintain perfusion. Patient was ultimately left with pelvic discontinuity, excision arthroplasty and pseudoarthrosis of the left hip. Avascular necrosis of acetabulum is a rare entity & often not recognized. One should be suspicious about diagnosis of avascular necrosis of acetabulum in select cases of failed acetabular fixation, previously operated via extensile anterior ilio - inguinal approach. Angiographic evaluation is essential in revision cases of failed acetabular fixation. Corona mortis (crown or circle of death) can sometimes act as a savior of limb.
2012-01-01
Background Rehabilitation technology for upper limb training of stroke patients may play an important role as therapy tool in future, in order to meet the increasing therapy demand. Currently, implementation of this technology in the clinic remains low. This study aimed at identifying criteria and conditions that people, involved in development of such technology, should take into account to achieve a (more) successful implementation of the technology in the clinic. Methods A literature search was performed in PubMed and IEEE databases, and semi-structured interviews with therapists in stroke rehabilitation were held, to identify criteria and conditions technology should meet to facilitate (implementation of) technology-assisted arm-hand skills training in rehabilitation therapy of stroke patients. In addition, an implementation strategy frequently applied in general health care was used to compose a stepwise guidance to facilitate successful implementation of this technology in therapy of stroke patients. Implementation-related criteria mentioned by therapists during the interviews were integrated in this guidance. Results Results indicate that, related to therapy content, technology should facilitate repetition of task-related movements, tailored to the patient and patient’s goals, in a meaningful context. Variability and increasing levels of difficulty in exercises should be on offer. Regarding hardware and software design of technology, the system should facilitate quick familiarisation and be easily adjustable to individual patients during therapy by therapists (and assistants). The system should facilitate adaptation to individual patients’ needs and their progression over time, should be adjustable as to various task-related variables, should be able to provide instructions and feedback, and should be able to document patient’s progression. The implementation process of technology in the clinic is provided as a stepwise guidance that consists of five phases therapists have to go through. The guidance includes criteria and conditions that motivate therapists, and make it possible for them, to actually use technology in their daily clinical practice. Conclusions The reported requirements are important as guidance for people involved in the development of rehabilitation technology for arm-hand therapy of stroke patients. The stepwise guide provides a tool for facilitating successful implementation of technology in clinical practice, thus meeting future therapy demand. PMID:22856548
What Can Students Learn in an Extended Role-Play Simulation on Technology and Society?
ERIC Educational Resources Information Center
Loui, Michael C.
2009-01-01
In a small course on technology and society, students participated in an extended role-play simulation for two weeks. Each student played a different adult character in a fictional community, which faces technological decisions in three scenarios set in the near future. The three scenarios involved stem cell research, nanotechnology, and privacy.…
Malosio, Matteo; Molinari Tosatti, Lorenzo
2017-01-01
Background The increase of sanitary costs related to poststroke rehabilitation requires new sustainable and cost-effective strategies for promoting autonomous and dehospitalized motor training. In the Riprendo@Home and Future Home for Future Communities research projects, the promising approach of introducing low-cost technologies that promote home rehabilitation is exploited. In order to provide reliable evaluation of patients, a reference database of healthy people's performances is required and should consider variability related to healthy people performances. Methods 78 healthy subjects performed several repetitions of daily-life gestures, the reaching movement (RM) and hand-to-mouth (HtMM) movement with both the dominant and nondominant upper limbs. Movements were recorded with a Kinect V2. A synthetic biomechanical protocol based on kinematical, dynamical, and motor control parameters was used to assess motor performance of the healthy people. The investigation was conducted by clustering participants depending on their limb dominancy (right/left), gender (male/female), and age (young/middle/senior) as sources of variability. Results Results showed that limb dominancy has minor relevance in affecting RM and HtMM; gender has relevance in affecting the HtMM; age has major effect in affecting RM and HtMM. Conclusions An investigation of healthy subjects' upper limb performances during daily-life gestures was performed with the Kinect V2 sensor. Findings will be the basis for a database of normative data for neurological patients' motor evaluation. PMID:29358893
Isaacson, Brad M.; Stinstra, Jeroen G.; Bloebaum, Roy D.; Pasquina, COL Paul F.; MacLeod, Rob S.
2011-01-01
Although the survival rates of warfighters in recent conflicts are among the highest in military history, those who have sustained proximal limb amputations, may pose additional rehabilitation concerns. In some of these cases, traditional prosthetic limbs may not provide adequate function for returning to an active lifestyle. Osseointegration has emerged as a potential prosthetic alternative for those with limited residual limb length. Using this technology, direct skeletal attachment occurs between a transcutaneous osseointegrated implant (TOI) and the host bone, thereby eliminating the need for a socket. While reports from the first 100 patients with a TOI have been promising, some rehabilitation regimens require 12–18 months of restricted weight bearing to prevent overloading at the bone implant-interface. Electrically induced osseointegration has been proposed as an option for expediting periprosthetic fixation and preliminary studies have demonstrated the feasibility of adapting the TOI into a functional cathode. To assure safe and effective electrical fields that are conducive for osseoinduction and osseointegration, we have developed multiscale modeling approaches to simulate the expected electric metrics at the bone-implant interface. We have used computed tomography scans and volume segmentation tools to create anatomically accurate models that clearly distinguish tissue parameters and serve as the basis for finite element analysis. This translational computational biological process has supported biomedical electrode design, implant placement, and experiments to date have demonstrated the clinical feasibility of electrically induced osseointegration. PMID:21712151
NASA Technical Reports Server (NTRS)
2001-01-01
This thermal infrared image was acquired by Mars Odyssey's thermal emission imaging system on October 30, 2001, as the spacecraft orbited Mars on its ninth revolution around the planet. The image was taken as part of the calibration and testing process of the camera system.
This image shows the temperature of Mars in one of the 10 thermal infrared filters. The spacecraft was approximately 22,000 kilometers (about 13,600 miles) above the planet looking down toward the south pole of Mars when this image was acquired.It is late spring in the martian southern hemisphere. The extremely cold, circular feature shown in blue is the martian south polar carbon dioxide ice cap at a temperature of about -120 oC (-184 o F). The cap is more than 900 kilometers (540 miles) in diameter at this time and will continue to shrink as summer progresses. Clouds of cooler air blowing off the cap can be seen in orange extending across the image to the left of the cap. The cold region in the lower right portion of the image shows the nighttime temperatures of Mars, demonstrating the 'night-vision' capability of the camera system to observe Mars even when the surface is in darkness. The warmest regions occur near local noontime. The ring of mountains surrounding the 900-kilometer (540-mile) diameter impact basin Argyre can be seen in the early afternoon in the upper portion of the image. The thin blue crescent along the upper limb of the planet is the martian atmosphere.This image covers a length of over 6,500 kilometers (3,900 miles) spanning the planet from limb to limb, with a resolution of approximately 5.5 kilometers per pixel (3.4 miles per pixel), or picture elements, at the point directly beneath the spacecraft. The Odyssey's infrared camera is planned to have a resolution of 100 meters per pixel (about 300 feet per pixel) from its mapping orbit.JPL manages the 2001 Mars Odyssey mission for NASA's Office of Space Science, Washington, D.C. The thermal emission imaging system was developed at Arizona State University, Tempe with Raytheon Santa Barbara Remote Sensing, Santa Barbara, Calif. Lockheed Martin Astronautics, Denver, Colo., is the prime contractor for the project, and developed and built the orbiter. Mission operations are conducted jointly from Lockheed Martin and from JPL, a division of the California Institute of Technology in Pasadena.Dynamic inter-limb resistance exercise device for long-duration space flight
NASA Technical Reports Server (NTRS)
Schwandt, Douglas F.; Watenpaugh, Donald E.; Parazynski, Scott E.; Hargens, Alan R.
1991-01-01
Essential for fitness on Earth, resistive exercise is even more important for astronauts, who must maintain muscle and bone strength in the absence of gravity. To meet this need, designers and scientists at NASA Ames Research Center, Life Science Division, have worked to develop more effective exercise devices for long-duration exposure to microgravity. One of these concepts is the Inter-Limb Resistance Device which allows the subject to exercise one limb directly against another, strengthening muscle groups in the arms, legs, and back. It features a modular harness with an inelastic cable and instrumented pulley. Forces similar to other high resistance exercise equipment are generated. Sensors in the pulley measure force and velocity for performance feedback display and data acquisition. This free-floating apparatus avoids vibration of sensitive experiments on board spacecraft. Compact with low mass, this hardware is also well suited for a 'safe haven' from radiation on board Space Station Freedom, and may prove useful in confined environments on Earth, such as Antarctic stations, submarines, and other underwater habitats. Potential spin-offs of this technology include products for personal strengthening and cardiovascular conditioning, rehabilitation of hospital patients, fitness exercise for the disabled, and retraining after sports injuries.
Improvement on upper limb body-powered prostheses (1921-2016): A systematic review.
Hashim, Nur Afiqah; Abd Razak, Nasrul Anuar; Abu Osman, Noor Azuan; Gholizadeh, Hossein
2018-01-01
Body-powered prostheses are known for their advantages of cost, reliability, training period, maintenance, and proprioceptive feedback. This study primarily aims to analyze the work related to the improvement of upper limb body-powered prostheses prior to 2016. A systematic review conducted via the search of the Web of Science electronic database, Google Scholar, and Google Patents identified 155 papers from 1921 to 2016. Sackett's initial rules of evidence were used to determine the levels of evidence, and only papers categorized in the design and development category and patents were analyzed. A total of 40 papers in the sixth level of "Design and Development" of an upper limb body-powered prosthesis were found. Approximately 81% were categorized under mechanical alteration. Most papers were patent-type documents (48%), with the Journal of Rehabilitation Research and Development publishing most of the articles related to the design and development of body-powered prostheses. Papers in the scope of the study were published once every 3 years in almost a century, proving that only a few studies were conducted to improve body-powered arms compared with myoelectric technology. Further research should be carried out mainly in areas that have received less attention.
Durability of implanted electrodes and leads in an upper-limb neuroprosthesis.
Kilgore, Kevin L; Peckham, P Hunter; Keith, Michael W; Montague, Fred W; Hart, Ronald L; Gazdik, Martha M; Bryden, Anne M; Snyder, Scott A; Stage, Thomas G
2003-01-01
Implanted neuroprosthetic systems have been successfully used to provide upper-limb function for over 16 years. A critical aspect of these implanted systems is the safety, stability, and-reliability of the stimulating electrodes and leads. These components are (1) the stimulating electrode itself, (2) the electrode lead, and (3) the lead-to-device connector. A failure in any of these components causes the direct loss of the capability to activate a muscle consistently, usually resulting in a decrement in the function provided by the neuroprosthesis. Our results indicate that the electrode, lead, and connector system are extremely durable. We analyzed 238 electrodes that have been implanted as part of an upper-limb neuroprosthesis. Each electrode had been implanted at least 3 years, with a maximum implantation time of over 16 years. Only three electrode-lead failures and one electrode infection occurred, for a survival rate of almost 99 percent. Electrode threshold measurements indicate that the electrode response is stable over time, with no evidence of electrode migration or continual encapsulation in any of the electrodes studied. These results have an impact on the design of implantable neuroprosthetic systems. The electrode-lead component of these systems should no longer be considered a weak technological link.
NASA Astrophysics Data System (ADS)
Jiang, Shengqian; Liu, Peng; Fu, Danni; Xue, Yiming; Luo, Wentao; Wang, Mingjie
2017-04-01
As an effective survey method of upper limb disorder, rapid upper limb assessment (RULA) has a wide application in industry period. However, it is very difficult to rapidly evaluate operator's postures in real complex work place. In this paper, a real-time RULA method is proposed to accurately assess the potential risk of operator's postures based on the somatosensory data collected from Kinect sensor, which is a line of motion sensing input devices by Microsoft. First, the static position information of each bone point is collected to obtain the effective angles of body parts based on the calculating methods based on joints angles. Second, a whole RULA score of body is obtained to assess the risk level of current posture in real time. Third, those RULA scores are compared with the results provided by a group of ergonomic practitionerswho were asked to observe the same static postures. All the experiments were carried out in an ergonomic lab. The results show that the proposed method can detect operator's postures more accurately. What's more, this method is applied in a real-time condition which can improve the evaluating efficiency.
Monitoring elbow isometric contraction by novel wearable fabric sensing device
NASA Astrophysics Data System (ADS)
Wang, Xi; Tao, Xiaoming; So, Raymond C. H.; Shu, Lin; Yang, Bao; Li, Ying
2016-12-01
Fabric-based wearable technology is highly desirable in sports, as it is light, flexible, soft, and comfortable with little interference to normal sport activities. It can provide accurate information on the in situ deformation of muscles in a continuous and wireless manner. During elbow flexion in isometric contraction, upper arm circumference increases with the contraction of elbow flexors, and it is possible to monitor the muscles’ contraction by limb circumferential strains. This paper presents a new wireless wearable anthropometric monitoring device made from fabric strain sensors for the human upper arm. The materials, structural design and calibration of the device are presented. Using an isokinetic testing system (Biodex3®) and the fabric monitoring device simultaneously, in situ measurements were carried out on elbow flexors in isometric contraction mode with ten subjects for a set of positions. Correlations between the measured values of limb circumferential strain and normalized torque were examined, and a linear relationship was found during isometric contraction. The average correlation coefficient between them is 0.938 ± 0.050. This wearable anthropometric device thus provides a useful index, the limb circumferential strain, for upper arm muscle contraction in isometric mode.
ARBOOK: Development and Assessment of a Tool Based on Augmented Reality for Anatomy
ERIC Educational Resources Information Center
Ferrer-Torregrosa, J.; Torralba, J.; Jimenez, M. A.; García, S.; Barcia, J. M.
2015-01-01
The evolution of technologies and the development of new tools with educational purposes are growing up. This work presents the experience of a new tool based on augmented reality (AR) focusing on the anatomy of the lower limb. ARBOOK was constructed and developed based on TC and MRN images, dissections and drawings. For ARBOOK evaluation, a…
Three upper limb robotic devices for stroke rehabilitation: a review and clinical perspective.
Bishop, Lauri; Stein, Joel
2013-01-01
Stroke is a leading cause of disability worldwide. Many survivors of stroke remain with residual disabilities, even years later. Advances in technology have led to the development of a variety of robotic devices for use in rehabilitation. The integration of robotics in the delivery of neurorehabilitation is promising, but still not widely used in clinical settings. The aim of this review is to discuss the general design of three typical upper limb robotic devices, and examine the practical considerations for their use in a clinical environment. Each device is described, the available clinical literature is reviewed and a clinical perspective is given on the usefulness of these robotic devices in rehabilitation of this population. Current literature supports the use of robotics in the clinical environment. However, claims that robotic therapy is more effective than traditional treatment is not substantially supported. The majority of clinical trials reported are small, and lack the use of a control group for comparison treatment. The use of robotics in stroke rehabilitation is still a relatively new treatment platform, and still evolving. As technological advances are made, there is much potential for growth in this field.
ERIC Educational Resources Information Center
Nair, Pradeep Kumar; Ali, Faizan; Leong, Lim Chee
2015-01-01
Purpose: This study aims to explain the factors affecting students' acceptance and usage of a lecture capture system (LCS)--ReWIND--in a Malaysian university based on the extended unified theory of acceptance and use of technology (UTAUT2) model. Technological advances have become an important feature of universities' plans to improve the…
ERIC Educational Resources Information Center
Teo, Timothy
2010-01-01
The purpose of this study is to examine pre-service teachers' attitudes to computers. This study extends the technology acceptance model (TAM) framework by adding subjective norm, facilitating conditions, and technological complexity as external variables. Results show that the TAM and subjective norm, facilitating conditions, and technological…
Truncating SLC5A7 mutations underlie a spectrum of dominant hereditary motor neuropathies.
Salter, Claire G; Beijer, Danique; Hardy, Holly; Barwick, Katy E S; Bower, Matthew; Mademan, Ines; De Jonghe, Peter; Deconinck, Tine; Russell, Mark A; McEntagart, Meriel M; Chioza, Barry A; Blakely, Randy D; Chilton, John K; De Bleecker, Jan; Baets, Jonathan; Baple, Emma L; Walk, David; Crosby, Andrew H
2018-04-01
To identify the genetic cause of disease in 2 previously unreported families with forms of distal hereditary motor neuropathies (dHMNs). The first family comprises individuals affected by dHMN type V, which lacks the cardinal clinical feature of vocal cord paralysis characteristic of dHMN-VII observed in the second family. Next-generation sequencing was performed on the proband of each family. Variants were annotated and filtered, initially focusing on genes associated with neuropathy. Candidate variants were further investigated and confirmed by dideoxy sequence analysis and cosegregation studies. Thorough patient phenotyping was completed, comprising clinical history, examination, and neurologic investigation. dHMNs are a heterogeneous group of peripheral motor neuron disorders characterized by length-dependent neuropathy and progressive distal limb muscle weakness and wasting. We previously reported a dominant-negative frameshift mutation located in the concluding exon of the SLC5A7 gene encoding the choline transporter (CHT), leading to protein truncation, as the likely cause of dominantly-inherited dHMN-VII in an extended UK family. In this study, our genetic studies identified distinct heterozygous frameshift mutations located in the last coding exon of SLC5A7 , predicted to result in the truncation of the CHT C-terminus, as the likely cause of the condition in each family. This study corroborates C-terminal CHT truncation as a cause of autosomal dominant dHMN, confirming upper limb predominating over lower limb involvement, and broadening the clinical spectrum arising from CHT malfunction.
Abrahamson, Jennie A; Fisher, Karen E; Turner, Anne G; Durrance, Joan C; Turner, Tammara Combs
2008-10-01
This research studied motivations for, barriers to, and effects of online health information seeking and explored lay information mediary behavior (LIMB) characteristics in the consumer health information domain. Lay information mediaries (LIMs) seek information on behalf or because of others, without necessarily being asked to do so or engaging in follow up, and have represented more than 50% of health information seekers in prior studies. A web-based survey was posted on NC Health Info (NCHI) with 211 respondents, self-identified per the information need that brought them to NCHI as 20% LIMs (n = 43), 58% direct users (n = 122), and 22% health or information providers (n = 46). Follow-up telephone interviews were performed with 10% (n = 21). Interview analysis focused on lay participants (n = 15 LIMs and direct users combined). Interviewees were reclassified post-survey as 12 LIMs and 3 direct users when studied information behavior extended beyond NCHI search. Interview data were analyzed using grounded theory approach. Surveyed LIMs were 77% female (n = 33) and searched on behalf or because of family members (81%, n = 35) and people they felt "extremely close" to (77%, n = 33). LIMs reported various information seeking barriers "sometimes" to "often." LIMs searched mostly without prompting (51%, n = 22). Interview results triangulated survey findings regarding gender, tie strength, and prompting. LIMB may be related to gender and relationship tie strength and appears more internally than externally motivated. Further LIMB research is warranted.
Mirror therapy for an adult with central post-stroke pain: a case report.
Corbetta, Davide; Sarasso, Elisabetta; Agosta, Federica; Filippi, Massimo; Gatti, Roberto
2018-01-01
Treatment of central post-stroke pain (CPSP) after a thalamic-capsular stroke is generally based on pharmacological approach as it is low responsive to physiotherapy. In this case report, the use of mirror therapy (MT) for the reduction of CPSP in a subject after a stroke involving thalamus is presented. Five years after a right lenticular-capsular thalamic stroke, despite a good recovery of voluntary movement that guaranteed independence in daily life activities, a 50-year-old woman presented with mild weakness and spasticity, an important sensory loss and a burning pain in the left upper limb. MT for reducing arm pain was administered in 45-min sessions, five days a week, for two consecutive weeks. MT consisted in performing symmetrical movements of both forearms and hands while watching the image of the sound limb reflected by a parasagittal mirror superimposed to the affected limb. Pain severity was assessed using visual analogue scale (VAS) before and after the intervention and at one-year follow-up. After the two weeks of MT, the patient demonstrated 4.5 points reduction in VAS pain score of the hand at rest and 3.9 points during a maximal squeeze left hand contraction. At one-year follow-up, pain reduction was maintained and also extended to the shoulder. This case report shows the successful application of a motor training with a sensory confounding condition (MT) in reducing CPSP in a patient with a chronic thalamic stroke.
Gillis, J. Andrew; Rawlinson, Kate A.; Bell, Justin; Lyon, Warrick S.; Baker, Clare V. H.; Shubin, Neil H.
2011-01-01
Chondrichthyans possess endoskeletal appendages called branchial rays that extend laterally from their hyoid and gill-bearing (branchial) arches. Branchial ray outgrowth, like tetrapod limb outgrowth, is maintained by Sonic hedgehog (Shh) signaling. In limbs, distal endoskeletal elements fail to form in the absence of normal Shh signaling, whereas shortened duration of Shh expression correlates with distal endoskeletal reduction in naturally variable populations. Chondrichthyans also exhibit natural variation with respect to branchial ray distribution—elasmobranchs (sharks and batoids) possess a series of ray-supported septa on their hyoid and gill arches, whereas holocephalans (chimaeras) possess a single hyoid arch ray-supported operculum. Here we show that the elongate hyoid rays of the holocephalan Callorhinchus milii grow in association with sustained Shh expression within an opercular epithelial fold, whereas Shh is only transiently expressed in the gill arches. Coincident with this transient Shh expression, branchial ray outgrowth is initiated in C. milii but is not maintained, yielding previously unrecognized vestigial gill arch branchial rays. This is in contrast to the condition seen in sharks, where sustained Shh expression corresponds to the presence of fully formed branchial rays on the hyoid and gill arches. Considered in light of current hypotheses of chondrichthyan phylogeny, our data suggest that the holocephalan operculum evolved in concert with gill arch appendage reduction by attenuation of Shh-mediated branchial ray outgrowth, and that chondrichthyan branchial rays and tetrapod limbs exhibit parallel developmental mechanisms of evolutionary reduction. PMID:21220324
NASA Technical Reports Server (NTRS)
Lowman, Paul. D., Jr.
1996-01-01
This paper proposes a comprehensive incremental program, Lunar Limb Observatory (LLO), for a return to the Moon, beginning with robotic missions and ending with a permanent lunar settlement. Several recent technological developments make such a program both affordable and scientifically valuable: robotic telescopes, the Internet, light-weight telescopes, shared- autonomy/predictive graphics telerobotic devices, and optical interferometry systems. Reasons for focussing new NASA programs on the Moon include public interest, Moon-based astronomy, renewed lunar exploration, lunar resources (especially helium-3), technological stimulus, accessibility of the Moon (compared to any planet), and dispersal of the human species to counter predictable natural catastrophes, asteroidal or cometary impacts in particular. The proposed Lunar Limb Observatory would be located in the crater Riccioli, with auxiliary robotic telescopes in M. Smythii and at the North and South Poles. The first phase of the program, after site certification, would be a series of 5 Delta-launched telerobotic missions to Riccioli (or Grimaldi if Riccioli proves unsuitable), emplacing robotic telescopes and carrying out surface exploration. The next phase would be 7 Delta-launched telerobotic missions to M. Smythii (2 missions), the South Pole (3 missions), and the North Pole (2 missions), emplacing robotic telescopes to provide continuous all-sky coverage. Lunar base establishment would begin with two unmanned Shuttle/Fitan-Centaur missions to Riccioli, for shelter emplacement, followed by the first manned return, also using the Shuttle/Fitan-Centaur mode. The main LLO at Riccioli would then be permanently or periodically inhabited, for surface exploration, telerobotic rover and telescope operation and maintenance, and support of Earth-based student projects. The LLO would evolve into a permanent human settlement, serving, among other functions, as a test area and staging base for the exploration, settlement, and terraforming of Mars.
NASA Astrophysics Data System (ADS)
Lowman, Paul. D., Jr.
1996-10-01
This paper proposes a comprehensive incremental program, Lunar Limb Observatory (LLO), for a return to the Moon, beginning with robotic missions and ending with a permanent lunar settlement. Several recent technological developments make such a program both affordable and scientifically valuable: robotic telescopes, the Internet, light-weight telescopes, shared- autonomy/predictive graphics telerobotic devices, and optical interferometry systems. Reasons for focussing new NASA programs on the Moon include public interest, Moon-based astronomy, renewed lunar exploration, lunar resources (especially helium-3), technological stimulus, accessibility of the Moon (compared to any planet), and dispersal of the human species to counter predictable natural catastrophes, asteroidal or cometary impacts in particular. The proposed Lunar Limb Observatory would be located in the crater Riccioli, with auxiliary robotic telescopes in M. Smythii and at the North and South Poles. The first phase of the program, after site certification, would be a series of 5 Delta-launched telerobotic missions to Riccioli (or Grimaldi if Riccioli proves unsuitable), emplacing robotic telescopes and carrying out surface exploration. The next phase would be 7 Delta-launched telerobotic missions to M. Smythii (2 missions), the South Pole (3 missions), and the North Pole (2 missions), emplacing robotic telescopes to provide continuous all-sky coverage. Lunar base establishment would begin with two unmanned Shuttle/Fitan-Centaur missions to Riccioli, for shelter emplacement, followed by the first manned return, also using the Shuttle/Fitan-Centaur mode. The main LLO at Riccioli would then be permanently or periodically inhabited, for surface exploration, telerobotic rover and telescope operation and maintenance, and support of Earth-based student projects. The LLO would evolve into a permanent human settlement, serving, among other functions, as a test area and staging base for the exploration, settlement, and terraforming of Mars.
Gradual decline in mobility with the adoption of food production in Europe
Ruff, Christopher B.; Holt, Brigitte; Niskanen, Markku; Sladek, Vladimir; Berner, Margit; Garofalo, Evan; Garvin, Heather M.; Hora, Martin; Junno, Juho-Antti; Schuplerova, Eliska; Vilkama, Rosa; Whittey, Erin
2015-01-01
Increased sedentism during the Holocene has been proposed as a major cause of decreased skeletal robusticity (bone strength relative to body size) in modern humans. When and why declining mobility occurred has profound implications for reconstructing past population history and health, but it has proven difficult to characterize archaeologically. In this study we evaluate temporal trends in relative strength of the upper and lower limb bones in a sample of 1,842 individuals from across Europe extending from the Upper Paleolithic [11,000–33,000 calibrated years (Cal y) B.P.] through the 20th century. A large decline in anteroposterior bending strength of the femur and tibia occurs beginning in the Neolithic (∼4,000–7,000 Cal y B.P.) and continues through the Iron/Roman period (∼2,000 Cal y B.P.), with no subsequent directional change. Declines in mediolateral bending strength of the lower limb bones and strength of the humerus are much smaller and less consistent. Together these results strongly implicate declining mobility as the specific behavioral factor underlying these changes. Mobility levels first declined at the onset of food production, but the transition to a more sedentary lifestyle was gradual, extending through later agricultural intensification. This finding only partially supports models that tie increased sedentism to a relatively abrupt Neolithic Demographic Transition in Europe. The lack of subsequent change in relative bone strength indicates that increasing mechanization and urbanization had only relatively small effects on skeletal robusticity, suggesting that moderate changes in activity level are not sufficient stimuli for bone deposition or resorption. PMID:26060299
Dynamics of BMP signaling in limb bud mesenchyme and polydactyly.
Norrie, Jacqueline L; Lewandowski, Jordan P; Bouldin, Cortney M; Amarnath, Smita; Li, Qiang; Vokes, Martha S; Ehrlich, Lauren I R; Harfe, Brian D; Vokes, Steven A
2014-09-15
Mutations in the Bone Morphogenetic Protein (BMP) pathway are associated with a range of defects in skeletal formation. Genetic analysis of BMP signaling requirements is complicated by the presence of three partially redundant BMPs that are required for multiple stages of limb development. We generated an inducible allele of a BMP inhibitor, Gremlin, which reduces BMP signaling. We show that BMPs act in a dose and time dependent manner in which early reduction of BMPs result in digit loss, while inhibiting overall BMP signaling between E10.5 and E11.5 allows polydactylous digit formation. During this period, inhibiting BMPs extends the duration of FGF signaling. Sox9 is initially expressed in normal digit ray domains but at reduced levels that correlate with the reduction in BMP signaling. The persistence of elevated FGF signaling likely promotes cell proliferation and survival, inhibiting the activation of Sox9 and secondarily, inhibiting the differentiation of Sox9-expressing chondrocytes. Our results provide new insights into the timing and clarify the mechanisms underlying BMP signaling during digit morphogenesis. Copyright © 2014 Elsevier Inc. All rights reserved.
Sarparanta, Jaakko; Jonson, Per Harald; Golzio, Christelle; Sandell, Satu; Luque, Helena; Screen, Mark; McDonald, Kristin; Stajich, Jeffrey M.; Mahjneh, Ibrahim; Vihola, Anna; Raheem, Olayinka; Penttilä, Sini; Lehtinen, Sara; Huovinen, Sanna; Palmio, Johanna; Tasca, Giorgio; Ricci, Enzo; Hackman, Peter; Hauser, Michael; Katsanis, Nicholas; Udd, Bjarne
2012-01-01
Limb-girdle muscular dystrophy type 1D (LGMD1D) was linked to 7q36 over a decade ago1, but its genetic cause has remained elusive. We have studied nine LGMD families from Finland, the U.S., and Italy, and identified four dominant missense mutations leading to p.Phe93Leu or p.Phe89Ile changes in the ubiquitously expressed co-chaperone DNAJB6. Functional testing in vivo showed that the mutations have a dominant toxic effect mediated specifically by the cytoplasmic isoform of DNAJB6. In vitro studies demonstrated that the mutations increase the half-life of DNAJB6, extending this effect to the wild-type protein, and reduce its protective anti-aggregation effect. Further, we show that DNAJB6 interacts with members of the CASA complex, including the myofibrillar-myopathy-causing protein BAG3. Our data provide the genetic cause of LGMD1D, suggest that the pathogenesis is mediated by defective chaperone function, and highlight how mutations expressed ubiquitously can exert their effect in a tissue-, cellular compartment-, and isoform-specific manner. PMID:22366786
Light Scattering by Lunar Exospheric Dust: What could be Learned from LRO LAMP and LADEE UVS?
NASA Astrophysics Data System (ADS)
Glenar, D. A.; Stubbs, T. J.; Richard, D. T.; Stern, S. A.; Retherford, K. D.; Gladstone, R.; Feldman, P. D.; Colaprete, A.; Delory, G. T.
2011-12-01
Two complementary spectrometers, namely the Lunar Reconnaissance Orbiter, Lyman Alpha Mapping Project (LAMP) and the planned Lunar Atmosphere and Dust Environment Explorer (LADEE) Ultraviolet Explorer (UVS) will carry out sensitive searches for high altitude exospheric dust, via detection of scattered sunlight. The combined spectral coverage of these instruments extends from far-UV to near-IR wavelengths. Over this wavelength range, grain size parameter (X=2πr/λ, with r the grain radius and λ the wavelength) changes dramatically, which makes broad wavelength coverage a good diagnostic of grain size. Utilizing different pointing geometries, both LAMP and UVS are able to observe dust over a range of scattering angles, as well as measure the dust vertical profile via limb measurements at multiple tangent heights. We summarize several categories of information that can be inferred from the data sets, using broadband simulations of horizon glow as observed at the limb. Grain scattering properties used in these simulations were computed for multiple grain shapes using Discrete-Dipole theory. Some cautionary remarks are included regarding the use of Mie theory to interpret scattering measurements.
Locomotor Adaptation to an Asymmetric Force on the Human Pelvis Directed Along the Right Leg.
Vashista, Vineet; Martelli, Dario; Agrawal, Sunil
2015-09-11
In this work, we study locomotor adaptation in healthy adults when an asymmetric force vector is applied to the pelvis directed along the right leg. A cable-driven Active Tethered Pelvic Assist Device (A-TPAD) is used to apply an external force on the pelvis, specific to a subject's gait pattern. The force vector is intended to provide external weight bearing during walking and modify the durations of limb supports. The motivation is to use this paradigm to improve weight bearing and stance phase symmetry in individuals with hemiparesis. An experiment with nine healthy subjects was conducted. The results show significant changes in the gait kinematics and kinetics while the healthy subjects developed temporal and spatial asymmetry in gait pattern in response to the applied force vector. This was followed by aftereffects once the applied force vector was removed. The adaptation to the applied force resulted in asymmetry in stance phase timing and lower limb muscle activity. We believe this paradigm, when extended to individuals with hemiparesis, can show improvements in weight bearing capability with positive effects on gait symmetry and walking speed.
Shinohara, H
1996-01-01
The nature of the nerve supply to the "pocket' of pectoralis major was examined on 7 randomly selected sides of 5 embalmed cadavers. The pocket was a U-shaped muscular fold, opening cranially. The anterior limb and inner surface of the fold were supplied by nerve branches that originated from the middle segment of the pectoral nerve loop and penetrated pectoralis minor. The outer surface of the posterior limb was supplied by one or two branches that extended from the caudal segment of the pectoral nerve loop. If the muscular U-shaped fold is unfolded, it becomes obvious that the posterior wall of the pocket forms the most caudal part of pectoralis major and is supplied from both the superficial (anterior) and deep (posterior) surfaces. This dual surface supply does not suggest any aspect of the developmental origin of the pocket but may simply be due to the relative positions of the pectoralis major and its nerve. Images Fig. 1 Fig. 2 Fig. 3 PMID:8621324
Kannape, Oliver A; Herr, Hugh M
2014-01-01
Although great advances have been made in the design and control of lower extremity prostheses, walking on different terrains, such as ramps or stairs, and transitioning between these terrains remains a major challenge for the field. In order to generalize biomimetic behaviour of active lower-limb prostheses top-down volitional control is required but has until recently been deemed unfeasible due to the difficulties involved in acquiring an adequate electromyographic (EMG) signal. In this study, we hypothesize that a transtibial amputee can extend the functionality of a hybrid controller, designed for level ground walking, to stair ascent and descent by volitionally modulating powered plantar-flexion of the prosthesis. We here present data illustrating that the participant is able to reproduce ankle push-off behaviour of the intrinsic controller during stair ascent as well as prevent inadvertent push-off during stair descent. Our findings suggest that EMG signal from the residual limb muscles can be used to transition between level-ground walking and stair ascent/descent within a single step and significantly improve prosthesis performance during stair-ambulation.
Jeonghee Kim; Parnell, Claire; Wichmann, Thomas; DeWeerth, Stephen P
2016-08-01
Assessments of tremor characteristics by movement disorder physicians are usually done at single time points in clinic settings, so that the description of the tremor does not take into account the dependence of the tremor on specific behavioral situations. Moreover, treatment-induced changes in tremor or behavior cannot be quantitatively tracked for extended periods of time. We developed a wearable tremor measurement system with tremor and activity recognition algorithms for long-term upper limb behavior tracking, to characterize tremor characteristics and treatment effects in their daily lives. In this pilot study, we collected sensor data of arm movement from three healthy participants using a wrist device that included a 3-axis accelerometer and a 3-axis gyroscope, and classified tremor and activities within scenario tasks which resembled real life situations. Our results show that the system was able to classify the tremor and activities with 89.71% and 74.48% accuracies during the scenario tasks. From this results, we expect to expand our tremor and activity measurement in longer time period.
Fong, Justin; Klaic, Marlena; Nair, Siddharth; Vetere, Frank; Cofré Lizama, L. Eduardo; Galea, Mary Pauline
2016-01-01
Background Stroke is a leading cause of disability worldwide, with upper limb deficits affecting an estimated 30% to 60% of survivors. The effectiveness of upper limb rehabilitation relies on numerous factors, particularly patient compliance to home programs and exercises set by therapists. However, therapists lack objective information about their patients’ adherence to rehabilitation exercises as well as other uses of the affected arm and hand in everyday life outside the clinic. We developed a system that consists of wearable sensor technology to monitor a patient’s arm movement and a Web-based dashboard to visualize this information for therapists. Objective The aim of our study was to evaluate how therapists use upper limb movement information visualized on a dashboard to support the rehabilitation process. Methods An interactive dashboard prototype with simulated movement information was created and evaluated through a user-centered design process with therapists (N=8) at a rehabilitation clinic. Data were collected through observations of therapists interacting with an interactive dashboard prototype, think-aloud data, and interviews. Data were analyzed qualitatively through thematic analysis. Results Therapists use visualizations of upper limb information in the following ways: (1) to obtain objective data of patients’ activity levels, exercise, and neglect outside the clinic, (2) to engage patients in the rehabilitation process through education, motivation, and discussion of experiences with activities of daily living, and (3) to engage with other clinicians and researchers based on objective data. A major limitation is the lack of contextual data, which is needed by therapists to discern how movement data visualized on the dashboard relate to activities of daily living. Conclusions Upper limb information captured through wearable devices provides novel insights for therapists and helps to engage patients and other clinicians in therapy. Consideration needs to be given to the collection and visualization of contextual information to provide meaningful insights into patient engagement in activities of daily living. These findings open the door for further work to develop a fully functioning system and to trial it with patients and clinicians during therapy. PMID:28582257
LeBlanc, M
1990-01-01
Present body-powered upper-limb prostheses use a cable control system employing World War II aircraft technology to transmit force from the body to the prosthesis for operation. The cable and associated hardware are located outside the prosthesis. Because individuals with arm amputations want prostheses that are natural looking with a smooth, soft outer surface, a design and development project was undertaken to replace the cable system with hydraulics located inside the prosthesis. Three different hydraulic transmission systems were built for evaluation, and other possibilities were explored. Results indicate that a hydraulic force transmission system remains an unmet challenge as a practical replacement for the cable system. The author was unable to develop a hydraulic system that meets the necessary dynamic requirements and is acceptable in size and appearance.
Aurora Australis, Spiked and Sinuous Red and Green Airglow
1991-05-06
STS039-342-026 (28 April-6 May 1991) --- This view of the Aurora Australis, or Southern Lights, shows a band of airglow above the limb of Earth. Photo experts at NASA studying the mission photography identify the airglow as being in the 80-120 kilometer altitude region and attribute its existence to atomic oxygen (wavelength of 5,577 Angstroms), although other atoms can also contribute. The atomic oxygen airglow is usually most intense at altitudes around 65 degrees north and south latitude, and is most intense in the spring and fall of the year. The aurora phenomena is due to atmospheric oxygen and nitrogen being excited by the particles from the Van Allen Radiation belts which extend between the two geomagnetic poles. The red and green rays appear to extend upward to 200-300 kilometers, much higher than the usual upper limits of about 110 kilometers.
Immediate tool incorporation processes determine human motor planning with tools
Ganesh, G.; Yoshioka, T.; Osu, R.; Ikegami, T.
2014-01-01
Human dexterity with tools is believed to stem from our ability to incorporate and use tools as parts of our body. However tool incorporation, evident as extensions in our body representation and peri-personal space, has been observed predominantly after extended tool exposures and does not explain our immediate motor behaviours when we change tools. Here we utilize two novel experiments to elucidate the presence of additional immediate tool incorporation effects that determine motor planning with tools. Interestingly, tools were observed to immediately induce a trial-by-trial, tool length dependent shortening of the perceived limb lengths, opposite to observations of elongations after extended tool use. Our results thus exhibit that tools induce a dual effect on our body representation; an immediate shortening that critically affects motor planning with a new tool, and the slow elongation, probably a consequence of skill related changes in sensory-motor mappings with the repeated use of the tool. PMID:25077612
Evolution of the human hip. Part 1: the osseous framework
Hogervorst, Tom; Vereecke, Evie E.
2014-01-01
Extensive osseous adaptations of the lumbar spine, pelvis, hip and femur characterize the emergence of the human bipedal gait with its ‘double extension’ of the lumbar spine and hip. To accommodate lumbar lordosis, the pelvis was ‘compacted’, becoming wider and shorter, as compared with the non-human apes. The hip joint acquired a much more extended position, which can be seen in a broader evolutionary context of verticalization of limbs. When loaded in a predominantly vertical position, the femur can be built lighter and longer than when it is loaded more horizontally because bending moments are smaller. Extension of the hip joint together with elongation of the femur increases effective leg length, and hence stride length, which improves energy efficiency. At the hip joint itself, the shift of the hip’s default working range to a more extended position influences concavity at the head–neck junction and femoral neck anteversion. PMID:27011802
Evolution of the human hip. Part 1: the osseous framework.
Hogervorst, Tom; Vereecke, Evie E
2014-10-01
Extensive osseous adaptations of the lumbar spine, pelvis, hip and femur characterize the emergence of the human bipedal gait with its 'double extension' of the lumbar spine and hip. To accommodate lumbar lordosis, the pelvis was 'compacted', becoming wider and shorter, as compared with the non-human apes. The hip joint acquired a much more extended position, which can be seen in a broader evolutionary context of verticalization of limbs. When loaded in a predominantly vertical position, the femur can be built lighter and longer than when it is loaded more horizontally because bending moments are smaller. Extension of the hip joint together with elongation of the femur increases effective leg length, and hence stride length, which improves energy efficiency. At the hip joint itself, the shift of the hip's default working range to a more extended position influences concavity at the head-neck junction and femoral neck anteversion.
A framework for investigation into extended enterprise resilience
NASA Astrophysics Data System (ADS)
Erol, Ozgur; Sauser, Brian J.; Mansouri, Mo
2010-05-01
This article proposes a framework for investigation into 'extended enterprise resilience' based on the key attributes of enterprise resilience in the context of extended enterprises. Such attributes, namely agility, flexibility, adaptability and connectivity, are frequently defined as supporting attributes of enterprise resilience, but the issue is how they can be more effectively applied to extended enterprises. The role of information technology in assisting connectivity and collaboration is frequently recognised as contributing to resilience on all levels, and will likewise be employed on the level of extended enterprise systems. The proposed framework is based on the expanded application of two primary enablers of enterprise resilience: (i) the capability of an enterprise to connect systems, people, processes and information in a way that allows enterprise to become more connected and responsive to the dynamics of its environment, stakeholders and competitors; (ii) the alignment of information technology with business goals. The former requires inter- and intra-level interoperability and integration within the extended enterprises, and the latter requires modelling of the underlying technology infrastructure and creation of a consolidated view of, and access to, all available resources in the extended enterprises that can be attained by well-defined enterprise architecture.
Dash, Biraja C; Thomas, Dilip; Monaghan, Michael; Carroll, Oliver; Chen, Xizhe; Woodhouse, Kimberly; O'Brien, Timothy; Pandit, Abhay
2015-10-01
Critical limb ischemia is a major clinical problem. Despite rigorous treatment regimes, there has been only modest success in reducing the rate of amputations in affected patients. Reduced level of blood flow and enhanced inflammation are the two major pathophysiological changes that occur in the ischemic tissue. The objective of this study was to develop a controlled dual gene delivery system capable of delivering therapeutic plasmid eNOS and IL-10 in a temporal manner. In order to deliver multiple therapeutic genes, an elastin-like polypeptide (ELP) based injectable system was designed. The injectable system was comprised of hollow spheres and an in situ-forming gel scaffold of elastin-like polypeptide capable of carrying gene complexes, with an extended manner release profile. In addition, the ELP based injectable system was used to deliver human eNOS and IL-10 therapeutic genes in vivo. A subcutaneous dose response study showed enhanced blood vessel density in the treatment groups of eNOS (20 μg) and IL-10 (10 μg)/eNOS (20 μg) and reduced inflammation with IL-10 (10 μg) alone. Next, we carried out a hind-limb ischemia model comparing the efficacy of the following interventions; Saline; IL-10, eNOS and IL-10/eNOS. The selected dose of eNOS, exhibited enhanced angiogenesis. IL-10 treatment groups showed reduction in the level of inflammatory cells. Furthermore, we demonstrated that eNOS up-regulated major proangiogenic growth factors such as vascular endothelial growth factors, platelet derived growth factor B, and fibroblast growth factor 1, which may explain the mechanism of this approach. These factors help in formation of a stable vascular network. Thus, ELP injectable system mediating non-viral delivery of human IL10-eNOS is a promising therapy towards treating limb ischemia. Copyright © 2015 Elsevier Ltd. All rights reserved.
Lam, Paul; Hebert, Debbie; Boger, Jennifer; Lacheray, Hervé; Gardner, Don; Apkarian, Jacob; Mihailidis, Alex
2008-01-01
Background It has been shown that intense training can significantly improve post-stroke upper-limb functionality. However, opportunities for stroke survivors to practice rehabilitation exercises can be limited because of the finite availability of therapists and equipment. This paper presents a haptic-enabled exercise platform intended to assist therapists and moderate-level stroke survivors perform upper-limb reaching motion therapy. This work extends on existing knowledge by presenting: 1) an anthropometrically-inspired design that maximizes elbow and shoulder range of motions during exercise; 2) an unobtrusive upper body postural sensing system; and 3) a vibratory elbow stimulation device to encourage muscle movement. Methods A multi-disciplinary team of professionals were involved in identifying the rehabilitation needs of stroke survivors incorporating these into a prototype device. The prototype system consisted of an exercise device, postural sensors, and a elbow stimulation to encourage the reaching movement. Eight experienced physical and occupational therapists participated in a pilot study exploring the usability of the prototype. Each therapist attended two sessions of one hour each to test and evaluate the proposed system. Feedback about the device was obtained through an administered questionnaire and combined with quantitative data. Results Seven of the nine questions regarding the haptic exercise device scored higher than 3.0 (somewhat good) out of 4.0 (good). The postural sensors detected 93 of 96 (97%) therapist-simulated abnormal postures and correctly ignored 90 of 96 (94%) of normal postures. The elbow stimulation device had a score lower than 2.5 (neutral) for all aspects that were surveyed, however the therapists felt the rehabilitation system was sufficient for use without the elbow stimulation device. Conclusion All eight therapists felt the exercise platform could be a good tool to use in upper-limb rehabilitation as the prototype was considered to be generally well designed and capable of delivering reaching task therapy. The next stage of this project is to proceed to clinical trials with stroke patients. PMID:18498641
Sediment Transport Dynamics and Bedform Evolution During Unsteady Flows
NASA Astrophysics Data System (ADS)
Hu, H.; Parsons, D. R.; Ockelford, A.; Hardy, R. J.; Ashworth, P. J.; Best, J.
2016-12-01
Dunes are ubiquitous features in sand bed rivers and estuaries, and their formation, growth and kinematics play a dominant role in boundary flow structure, flow resistance and sediment transport processes. However, bedform evolution and dynamics during the rising/falling limb of a flood wave remain poorly understood. Herein, we report on a series of flume experiments, undertaken at the University of Hull's Total Environment Simulator flume/wave tank facility, with imposed flow variations and different hydrographs: i) a sudden (shock) change, ii) a fast flood wave and iii) a slow flood wave. Our analysis shows that, because of changes of sediment transport mechanisms with discharge, the sediment flux rather than bedform migration rate is a more appropriate parameter to relate to transport stage. This is particularly the case during bedload transport dominated periods at lower flow discharge, where a strong power law relationship was detected. In terms of varying processes across the hydrograph limbs, bedform evolution during the rising limb is dominated not only by bedform amalgamation but also by the washing out of smaller-scale bedforms. Furthermore, bedform growth is independent of the rising rate of the hydrograph limb, while evolution of bedform decay is affected by the rate of discharge decrease. This results in an anticlockwise hysteresis between transport stage and total flux was found in fast wave experiment, indicating a significant role of the change in sediment transport mechanisms on bedform evolution. Moreover, analysis on the variation of deformation fraction (F, ratio of the deformation flux to the total bed material flux) suggests that net degradation of the bed enhances bedform deformation and leads to a higher F ( 0.65). This work extends our knowledge on how dunes generate and develop under variable flows and has begun to explore how variations in transport stage can be coupled with the variation in sediment transport mechanisms, and/or sediment supply which can help improve the modelling of sediment transport processes.
Large Extremity Peripheral Nerve Repair
2015-10-01
Outcomes are unsatisfactory, affecting quality of life and return to active duty. We are investigating a sutureless, light- activated technology for...on Avance® nerve graft procedure for large animal studies in Aim 3. (All PIs, Month 22) This study shows that outcomes following light- activated ...when severe injuries, complicated with limb loss, preclude the use of autograft. The demonstrated success of light- activated sealing of isograft
Hypervelocity Technology Escape System Concepts. Volume 1. Development and Evaluation
1988-07-01
airplane escape systems. These include separation at high dynamic pressure, stability, impact attenuation , crew member accelerations, adequate...changes (TTS; 0 Shock attenuator design PTS) 0 Restraint system design * Limb flail * Non-auditory changes (gag, dec. visual acuity) * Reduced psycho-motor...detected by ultrasonic technique. The DCS symptoms may not appear until at slightly lower total pressures (8 N psia - 9 pals). Since the pressurization
Ethylene Control Technologies in Extending Postharvest Shelf Life of Climacteric Fruit.
Zhang, Junhua; Cheng, Dong; Wang, Baobin; Khan, Iqbal; Ni, Yonghao
2017-08-30
Fresh fruit is important for a healthy diet. However, because of their seasonal production, regional specific cultivation, and perishable nature, it is essential to develop preservation technologies to extend the postharvest shelf life of fresh fruits. Climacteric fruit adopt spoilage because of ethylene, a key hormone associated with the ripening process. Therefore, controlling ethylene activity by following safe and effective approaches is a key to extend the postharvest shelf life of fruit. In this review, ethylene control technologies will be discussed aiming for the need of developing more innovative and effective approaches. The biosynthesis pathway will be given first. Then, the technologies determining the postharvest shelf life of climacteric fruit will be described with special attention to the latest and significant published works in this field. Special attention is given to 1-methylcyclopropene (1-MCP), which is effective in fruit preservation technologies. Finally, the encapsulation technology to improve the stability of 1-MCP will be proposed, using a potential encapsulation agent of 1-MCP, calixarene.
Teleb, Mohamed; Wardi, Miraie; Gosavi, Sucheta; Said, Sarmad; Mukherjee, Debabrata
2015-01-01
Peripheral arterial disease (PAD), a major cause of morbidity and mortality worldwide, is characterized by intermittent claudication and is associated with chronic diseases such as diabetes and hypertension. The goal of treatment is to address the underlying cause and to modify risk factors. Although medical management is the first-line treatment of PAD, some individuals may have severe symptoms and require revascularization with percutaneous transluminal angioplasty with or without stent placement or surgery. Interventional approaches may, however, be associated with high prevalence of restenosis and subsequent complications such as critical limb ischemia and amputation. Drug-eluting balloons (DEBs) are a new interventional technology with the primary goal of preventing restenosis. We review the clinical trials and studies that assessed the efficacy and safety profile of DEB and will focus on the restenosis rate in femoropopliteal arteries including target lesion revascularization (TLR) and late lumen lesion (LLL) using different modalities of intervention such as stents and DEB. Average data collected from the trials reported included restenosis rate of 25%, 0.3 mm LLL, and 14% reduction in TLR with DEB versus uncoated balloons. Below the knee (BTK) only intervention studies were excluded from this review as endovascular approach is usually reserved for critical limb ischemia for BTK disease. Interventional approach to treat PAD with DEB appears to be a promising technology. Additional larger studies are needed to further define safety, efficacy, and longer term outcome with this novel technology. PMID:27231422
ERIC Educational Resources Information Center
Carr, Patrick L.
2017-01-01
This dissertation analyzes how North Carolina State University's (NCSU) James B. Hunt Jr. Library extends the ways in which the information architectures of academic research libraries can function as a technology, as discourse, and as rhetoric. The starting point for the analysis is the libraries of antiquity, which functioned technologically as…
Classification of different reaching movements from the same limb using EEG
NASA Astrophysics Data System (ADS)
Shiman, Farid; López-Larraz, Eduardo; Sarasola-Sanz, Andrea; Irastorza-Landa, Nerea; Spüler, Martin; Birbaumer, Niels; Ramos-Murguialday, Ander
2017-08-01
Objective. Brain-computer-interfaces (BCIs) have been proposed not only as assistive technologies but also as rehabilitation tools for lost functions. However, due to the stochastic nature, poor spatial resolution and signal to noise ratio from electroencephalography (EEG), multidimensional decoding has been the main obstacle to implement non-invasive BCIs in real-live rehabilitation scenarios. This study explores the classification of several functional reaching movements from the same limb using EEG oscillations in order to create a more versatile BCI for rehabilitation. Approach. Nine healthy participants performed four 3D center-out reaching tasks in four different sessions while wearing a passive robotic exoskeleton at their right upper limb. Kinematics data were acquired from the robotic exoskeleton. Multiclass extensions of Filter Bank Common Spatial Patterns (FBCSP) and a linear discriminant analysis (LDA) classifier were used to classify the EEG activity into four forward reaching movements (from a starting position towards four target positions), a backward movement (from any of the targets to the starting position and rest). Recalibrating the classifier using data from previous or the same session was also investigated and compared. Main results. Average EEG decoding accuracy were significantly above chance with 67%, 62.75%, and 50.3% when decoding three, four and six tasks from the same limb, respectively. Furthermore, classification accuracy could be increased when using data from the beginning of each session as training data to recalibrate the classifier. Significance. Our results demonstrate that classification from several functional movements performed by the same limb is possible with acceptable accuracy using EEG oscillations, especially if data from the same session are used to recalibrate the classifier. Therefore, an ecologically valid decoding could be used to control assistive or rehabilitation mutli-degrees of freedom (DoF) robotic devices using EEG data. These results have important implications towards assistive and rehabilitative neuroprostheses control in paralyzed patients.
Pasquina, Paul F; Evangelista, Melissa; Carvalho, A J; Lockhart, Joseph; Griffin, Sarah; Nanos, George; McKay, Patricia; Hansen, Morten; Ipsen, Derek; Vandersea, James; Butkus, Josef; Miller, Matthew; Murphy, Ian; Hankin, David
2015-04-15
Advanced motorized prosthetic devices are currently controlled by EMG signals generated by residual muscles and recorded by surface electrodes on the skin. These surface recordings are often inconsistent and unreliable, leading to high prosthetic abandonment rates for individuals with upper limb amputation. Surface electrodes are limited because of poor skin contact, socket rotation, residual limb sweating, and their ability to only record signals from superficial muscles, whose function frequently does not relate to the intended prosthetic function. More sophisticated prosthetic devices require a stable and reliable interface between the user and robotic hand to improve upper limb prosthetic function. Implantable Myoelectric Sensors (IMES(®)) are small electrodes intended to detect and wirelessly transmit EMG signals to an electromechanical prosthetic hand via an electro-magnetic coil built into the prosthetic socket. This system is designed to simultaneously capture EMG signals from multiple residual limb muscles, allowing the natural control of multiple degrees of freedom simultaneously. We report the status of the first FDA-approved clinical trial of the IMES(®) System. This study is currently in progress, limiting reporting to only preliminary results. Our first subject has reported the ability to accomplish a greater variety and complexity of tasks in his everyday life compared to what could be achieved with his previous myoelectric prosthesis. The interim results of this study indicate the feasibility of utilizing IMES(®) technology to reliably sense and wirelessly transmit EMG signals from residual muscles to intuitively control a three degree-of-freedom prosthetic arm. Copyright © 2014 Elsevier B.V. All rights reserved.
Pasquina, Paul F.; Evangelista, Melissa; Carvalho, Antonio J.; Lockhart, Joseph; Griffin, Sarah; Nanos, George; McKay, Patricia; Hansen, Morten; Ipsen, Derek; Vandersea, James; Butkus, Josef; Miller, Matthew; Murphy, Ian; Hankin, David
2014-01-01
Background Advanced motorized prosthetic devices are currently controlled by EMG signals generated by residual muscles and recorded by surface electrodes on the skin. These surface recordings are often inconsistent and unreliable, leading to high prosthetic abandonment rates for individuals with upper limb amputation. Surface electrodes are limited because of poor skin contact, socket rotation, residual limb sweating, and their ability to only record signals from superficial muscles, whose function frequently does not relate to the intended prosthetic function. More sophisticated prosthetic devices require a stable and reliable interface between the user and robotic hand to improve upper limb prosthetic function. New Method Implantable Myoelectric Sensors (IMES®) are small electrodes intended to detect and wirelessly transmit EMG signals to an electromechanical prosthetic hand via an electromagnetic coil built into the prosthetic socket. This system is designed to simultaneously capture EMG signals from multiple residual limb muscles, allowing the natural control of multiple degrees of freedom simultaneously. Results We report the status of the first FDA-approved clinical trial of the IMES® System. This study is currently in progress, limiting reporting to only preliminary results. Comparison with Existing Methods Our first subject has reported the ability to accomplish a greater variety and complexity of tasks in his everyday life compared to what could be achieved with his previous myoelectric prosthesis. Conclusion The interim results of this study indicate the feasibility of utilizing IMES® technology to reliably sense and wirelessly transmit EMG signals from residual muscles to intuitively control a three degree-of-freedom prosthetic arm. PMID:25102286
Recent origin of low trabecular bone density in modern humans
Chirchir, Habiba; Kivell, Tracy L.; Ruff, Christopher B.; Hublin, Jean-Jacques; Carlson, Kristian J.; Zipfel, Bernhard; Richmond, Brian G.
2015-01-01
Humans are unique, compared with our closest living relatives (chimpanzees) and early fossil hominins, in having an enlarged body size and lower limb joint surfaces in combination with a relatively gracile skeleton (i.e., lower bone mass for our body size). Some analyses have observed that in at least a few anatomical regions modern humans today appear to have relatively low trabecular density, but little is known about how that density varies throughout the human skeleton and across species or how and when the present trabecular patterns emerged over the course of human evolution. Here, we test the hypotheses that (i) recent modern humans have low trabecular density throughout the upper and lower limbs compared with other primate taxa and (ii) the reduction in trabecular density first occurred in early Homo erectus, consistent with the shift toward a modern human locomotor anatomy, or more recently in concert with diaphyseal gracilization in Holocene humans. We used peripheral quantitative CT and microtomography to measure trabecular bone of limb epiphyses (long bone articular ends) in modern humans and chimpanzees and in fossil hominins attributed to Australopithecus africanus, Paranthropus robustus/early Homo from Swartkrans, Homo neanderthalensis, and early Homo sapiens. Results show that only recent modern humans have low trabecular density throughout the limb joints. Extinct hominins, including pre-Holocene Homo sapiens, retain the high levels seen in nonhuman primates. Thus, the low trabecular density of the recent modern human skeleton evolved late in our evolutionary history, potentially resulting from increased sedentism and reliance on technological and cultural innovations. PMID:25535354
Upper limb prosthesis use and abandonment: a survey of the last 25 years.
Biddiss, Elaine A; Chau, Tom T
2007-09-01
This review presents an analytical and comparative survey of upper limb prosthesis acceptance and abandonment as documented over the past 25 years, detailing areas of consumer dissatisfaction and ongoing technological advancements. English-language articles were identified in a search of Ovid, PubMed, and ISI Web of Science (1980 until February 2006) for key words upper limb and prosthesis. Articles focused on upper limb prostheses and addressing: (i) Factors associated with abandonment; (ii) Rejection rates; (iii) Functional analyses and patterns of wear; and (iv) Consumer satisfaction, were extracted with the exclusion of those detailing tools for outcome measurement, case studies, and medical procedures. Approximately 200 articles were included in the review process with 40 providing rates of prosthesis rejection. Quantitative measures of population characteristics, study methodology, and prostheses in use were extracted from each article. Mean rejection rates of 45% and 35% were observed in the literature for body-powered and electric prostheses respectively in pediatric populations. Significantly lower rates of rejection for both body-powered (26%) and electric (23%) devices were observed in adult populations while the average incidence of non-wear was similar for pediatric (16%) and adult (20%) populations. Documented rates of rejection exhibit a wide range of variance, possibly due to the heterogeneous samples involved and methodological differences between studies. Future research should comprise of controlled, multifactor studies adopting standardized outcome measures in order to promote comprehensive understanding of the factors affecting prosthesis use and abandonment. An enhanced understanding of these factors is needed to optimize prescription practices, guide design efforts, and satiate demand for evidence-based measures of intervention.
Recent origin of low trabecular bone density in modern humans.
Chirchir, Habiba; Kivell, Tracy L; Ruff, Christopher B; Hublin, Jean-Jacques; Carlson, Kristian J; Zipfel, Bernhard; Richmond, Brian G
2015-01-13
Humans are unique, compared with our closest living relatives (chimpanzees) and early fossil hominins, in having an enlarged body size and lower limb joint surfaces in combination with a relatively gracile skeleton (i.e., lower bone mass for our body size). Some analyses have observed that in at least a few anatomical regions modern humans today appear to have relatively low trabecular density, but little is known about how that density varies throughout the human skeleton and across species or how and when the present trabecular patterns emerged over the course of human evolution. Here, we test the hypotheses that (i) recent modern humans have low trabecular density throughout the upper and lower limbs compared with other primate taxa and (ii) the reduction in trabecular density first occurred in early Homo erectus, consistent with the shift toward a modern human locomotor anatomy, or more recently in concert with diaphyseal gracilization in Holocene humans. We used peripheral quantitative CT and microtomography to measure trabecular bone of limb epiphyses (long bone articular ends) in modern humans and chimpanzees and in fossil hominins attributed to Australopithecus africanus, Paranthropus robustus/early Homo from Swartkrans, Homo neanderthalensis, and early Homo sapiens. Results show that only recent modern humans have low trabecular density throughout the limb joints. Extinct hominins, including pre-Holocene Homo sapiens, retain the high levels seen in nonhuman primates. Thus, the low trabecular density of the recent modern human skeleton evolved late in our evolutionary history, potentially resulting from increased sedentism and reliance on technological and cultural innovations.
Guterstam, Arvid; Brozzoli, Claudio; Ehrsson, H. Henrik
2013-01-01
The perception of our limbs in space is built upon the integration of visual, tactile, and proprioceptive signals. Accumulating evidence suggests that these signals are combined in areas of premotor, parietal, and cerebellar cortices. However, it remains to be determined whether neuronal populations in these areas integrate hand signals according to basic temporal and spatial congruence principles of multisensory integration. Here, we developed a setup based on advanced 3D video technology that allowed us to manipulate the spatiotemporal relationships of visuotactile (VT) stimuli delivered on a healthy human participant's real hand during fMRI and investigate the ensuing neural and perceptual correlates. Our experiments revealed two novel findings. First, we found responses in premotor, parietal, and cerebellar regions that were dependent upon the spatial and temporal congruence of VT stimuli. This multisensory integration effect required a simultaneous match between the seen and felt postures of the hand, which suggests that congruent visuoproprioceptive signals from the upper limb are essential for successful VT integration. Second, we observed that multisensory conflicts significantly disrupted the default feeling of ownership of the seen real limb, as indexed by complementary subjective, psychophysiological, and BOLD measures. The degree to which self-attribution was impaired could be predicted from the attenuation of neural responses in key multisensory areas. These results elucidate the neural bases of the integration of multisensory hand signals according to basic spatiotemporal principles and demonstrate that the disintegration of these signals leads to “disownership” of the seen real hand. PMID:23946393
Regenerative Engineering and Bionic Limbs.
James, Roshan; Laurencin, Cato T
2015-03-01
Amputations of the upper extremity are severely debilitating, current treatments support very basic limb movement, and patients undergo extensive physiotherapy and psychological counselling. There is no prosthesis that allows the amputees near-normal function. With increasing number of amputees due to injuries sustained in accidents, natural calamities and international conflicts, there is a growing requirement for novel strategies and new discoveries. Advances have been made in technological, material and in prosthesis integration where researchers are now exploring artificial prosthesis that integrate with the residual tissues and function based on signal impulses received from the residual nerves. Efforts are focused on challenging experts in different disciplines to integrate ideas and technologies to allow for the regeneration of injured tissues, recording on tissue signals and feed-back to facilitate responsive movements and gradations of muscle force. A fully functional replacement and regenerative or integrated prosthesis will rely on interface of biological process with robotic systems to allow individual control of movement such as at the elbow, forearm, digits and thumb in the upper extremity. Regenerative engineering focused on the regeneration of complex tissue and organ systems will be realized by the cross-fertilization of advances over the past thirty years in the fields of tissue engineering, nanotechnology, stem cell science, and developmental biology. The convergence of toolboxes crated within each discipline will allow interdisciplinary teams from engineering, science, and medicine to realize new strategies, mergers of disparate technologies, such as biophysics, smart bionics, and the healing power of the mind. Tackling the clinical challenges, interfacing the biological process with bionic technologies, engineering biological control of the electronic systems, and feed-back will be the important goals in regenerative engineering over the next two decades.
Regenerative Engineering and Bionic Limbs
James, Roshan; Laurencin, Cato T.
2015-01-01
Amputations of the upper extremity are severely debilitating, current treatments support very basic limb movement, and patients undergo extensive physiotherapy and psychological counselling. There is no prosthesis that allows the amputees near-normal function. With increasing number of amputees due to injuries sustained in accidents, natural calamities and international conflicts, there is a growing requirement for novel strategies and new discoveries. Advances have been made in technological, material and in prosthesis integration where researchers are now exploring artificial prosthesis that integrate with the residual tissues and function based on signal impulses received from the residual nerves. Efforts are focused on challenging experts in different disciplines to integrate ideas and technologies to allow for the regeneration of injured tissues, recording on tissue signals and feed-back to facilitate responsive movements and gradations of muscle force. A fully functional replacement and regenerative or integrated prosthesis will rely on interface of biological process with robotic systems to allow individual control of movement such as at the elbow, forearm, digits and thumb in the upper extremity. Regenerative engineering focused on the regeneration of complex tissue and organ systems will be realized by the cross-fertilization of advances over the past thirty years in the fields of tissue engineering, nanotechnology, stem cell science, and developmental biology. The convergence of toolboxes crated within each discipline will allow interdisciplinary teams from engineering, science, and medicine to realize new strategies, mergers of disparate technologies, such as biophysics, smart bionics, and the healing power of the mind. Tackling the clinical challenges, interfacing the biological process with bionic technologies, engineering biological control of the electronic systems, and feed-back will be the important goals in regenerative engineering over the next two decades. PMID:25983525
75 FR 74001 - Application Deadline Extended; Secretarial Business India High Technology Mission
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-30
... Extended; Secretarial Business India High Technology Mission AGENCY: Department of Commerce. ACTION: Notice... New Delhi, Mumbai and Bangalore, India, February 6-11, 2011. The overall focus of the trip will be... India[email protected] . Applications received after that date will be considered only if space and...
Low-power polling mode of the next-generation IMES2 implantable wireless EMG sensor.
DeMichele, Glenn A; Hu, Zhe; Troyk, Philip R; Chen, Hongnan; Weir, Richard F ff
2014-01-01
The IMES1 Implantable MyoElectric Sensor device is currently in human clinical trials led by the Alfred Mann Foundation. The IMES is implanted in a residual limb and is powered wirelessly using a magnetic field. EMG signals resulting from the amputee's voluntary movement are amplified and transmitted wirelessly by the IMES to an external controller which controls movement of an external motorized prosthesis. Development of the IMES technology is on-going, producing the next-generation IMES2. Among various improvements, a new feature of the IMES2 is a low-power polling mode. In this low-power mode, the IMES2 power consumption can be dramatically reduced when the limb is inactive through the use of a polled sampling. With the onset of EMG activity, the IMES2 system can switch to the normal higher sample rate to allow the acquisition of high-fidelity EMG data for prosthesis control.
Low-Power Polling Mode of the Next-Generation IMES2 Implantable Wireless EMG Sensor
DeMichele, Glenn A.; Hu, Zhe; Troyk, Philip R.; Chen, Hongnan; Weir, Richard F. ff.
2015-01-01
The IMES1 Implantable MyoElectric Sensor device is currently in human clinical trials led by the Alfred Mann Foundation. The IMES is implanted in a residual limb and is powered wirelessly using a magnetic field. EMG signals resulting from the amputee’s voluntary movement are amplified and transmitted wirelessly by the IMES to an external controller which controls movement of an external motorized prosthesis. Development of the IMES technology is on-going, producing the next-generation IMES2. Among various improvements, a new feature of the IMES2 is a lowpower polling mode. In this low-power mode, the IMES2 power consumption can be dramatically reduced when the limb is inactive through the use of a polled sampling. With the onset of EMG activity, the IMES2 system can switch to the normal higher sample rate to allow the acquisition of high-fidelity EMG data for prosthesis control. PMID:25570642
Implementation An image processing technique for video motion analysis during the gait cycle canine
NASA Astrophysics Data System (ADS)
López, G.; Hernández, J. O.
2017-01-01
Nowadays the analyses of human movement, more specifically of the gait have ceased to be a priority for our species. Technological advances and implementations engineering have joined to obtain data and information regarding the gait cycle in another animal species. The aim of this paper is to analyze the canine gait in order to get results that describe the behavior of the limbs during the gait cycle. The research was performed by: 1. Dog training, where it is developed the step of adaptation and trust; 2. Filming gait cycle; 3. Data acquisition, in order to obtain values that describe the motion cycle canine and 4. Results, obtaining the kinematics variables involved in the march. Which are essential to determine the behavior of the limbs, as well as for the development of prosthetic or orthotic. This project was carried out with conventional equipment and using computational tools easily accessible.
Computer vision-based classification of hand grip variations in neurorehabilitation.
Zariffa, José; Steeves, John D
2011-01-01
The complexity of hand function is such that most existing upper limb rehabilitation robotic devices use only simplified hand interfaces. This is in contrast to the importance of the hand in regaining function after neurological injury. Computer vision technology has been used to identify hand posture in the field of Human Computer Interaction, but this approach has not been translated to the rehabilitation context. We describe a computer vision-based classifier that can be used to discriminate rehabilitation-relevant hand postures, and could be integrated into a virtual reality-based upper limb rehabilitation system. The proposed system was tested on a set of video recordings from able-bodied individuals performing cylindrical grasps, lateral key grips, and tip-to-tip pinches. The overall classification success rate was 91.2%, and was above 98% for 6 out of the 10 subjects. © 2011 IEEE
Wijesekera, Lokesh C; Leigh, P Nigel
2009-01-01
Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease characterised by progressive muscular paralysis reflecting degeneration of motor neurones in the primary motor cortex, corticospinal tracts, brainstem and spinal cord. Incidence (average 1.89 per 100,000/year) and prevalence (average 5.2 per100,000) are relatively uniform in Western countries, although foci of higher frequency occur in the Western Pacific. The mean age of onset for sporadic ALS is about 60 years. Overall, there is a slight male prevalence (M:F ratio~1.5:1). Approximately two thirds of patients with typical ALS have a spinal form of the disease (limb onset) and present with symptoms related to focal muscle weakness and wasting, where the symptoms may start either distally or proximally in the upper and lower limbs. Gradually, spasticity may develop in the weakened atrophic limbs, affecting manual dexterity and gait. Patients with bulbar onset ALS usually present with dysarthria and dysphagia for solid or liquids, and limbs symptoms can develop almost simultaneously with bulbar symptoms, and in the vast majority of cases will occur within 1–2 years. Paralysis is progressive and leads to death due to respiratory failure within 2–3 years for bulbar onset cases and 3–5 years for limb onset ALS cases. Most ALS cases are sporadic but 5–10% of cases are familial, and of these 20% have a mutation of the SOD1 gene and about 2–5% have mutations of the TARDBP (TDP-43) gene. Two percent of apparently sporadic patients have SOD1 mutations, and TARDBP mutations also occur in sporadic cases. The diagnosis is based on clinical history, examination, electromyography, and exclusion of 'ALS-mimics' (e.g. cervical spondylotic myelopathies, multifocal motor neuropathy, Kennedy's disease) by appropriate investigations. The pathological hallmarks comprise loss of motor neurones with intraneuronal ubiquitin-immunoreactive inclusions in upper motor neurones and TDP-43 immunoreactive inclusions in degenerating lower motor neurones. Signs of upper motor neurone and lower motor neurone damage not explained by any other disease process are suggestive of ALS. The management of ALS is supportive, palliative, and multidisciplinary. Non-invasive ventilation prolongs survival and improves quality of life. Riluzole is the only drug that has been shown to extend survival. PMID:19192301
Xiao, Jian; Mao, Zhao-Guang; Zhu, Hui-Hua; Guo, Liang
2017-03-25
To discuss the curative effect of the early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect. From December 2013 to January 2015, 36 cases of lower limb open comminuted fractures complicated with bone defects were treated by the vancomycin ALBC combined with the external fixation support, including 26 males and 10 females with an average age of 38.0 years old ranging from 19 to 65 years old. The included cases were all open fractures of lower limbs complicated with bone defects with different degree of soft tissue injuries. Among them, 25 cases were tibial fractures, 11 cases were femoral fractures. The radiographs indicated a presence of bone defects, which ranged from 3.0 to 6.1 cm with an average of 4.0 cm. The Gustilo classification of open fractures:24 cases were type IIIA, 12 cases were typr IIIB. The percentage of wound infection, bone grafting time, fracture healing time and postoperative joint function of lower limb were observed. The function of injured limbs was evaluated at 1 month after the clinical healing of fracture based on Paley evaluation criterion. All cases were followed up for 3 to 24 months with an average of (6.0±3.0) months. The wound surface was healed well, neither bone infections nor unhealed bone defects were presented. The reoperation of bone grafting was done at 6 weeks after the patients received an early treatment with ALBC, some of them were postponed to 8 weeks till the approximate healing of fractures, the treatment course lasted for 4 to 8 months with an average of(5.5±1.5) months. According to Paley and other grading evaluations of bone and function, there were 27 cases as excellent, 5 cases as good, 3 cases as ordinary. The ALBC combined with external fixation support was an effective method for early treatment to treat the traumatic lower limb open fractures complicated with bone defects. This method was typified with the advantages such as easy operation, short operation time, overwhelming superiority in controlling infection and provision of good bone grafting bed, a good bone healing can be realized by the use of membrane induction technology for bone grafting.
An assistive lower limb exoskeleton for people with neurological gait disorders.
Ortlieb, A; Bouri, M; Baud, R; Bleuler, H
2017-07-01
Lower limb exoskeletons have already proven the capability to give back mobility to people suffering from spinal cord injury (SCI). Other important populations such as people with multiple sclerosis or muscular dystrophy, frail elderly and stroke victims, suffer from severe gait impairments and could benefit from similar technology. The work presented in the current paper describes a novel design of a 6-actuated degrees of freedom (DOFs) assistive lower limb exoskeleton for people with moderate mobility impairments. The electrical actuators are all remotely located on the back of the user for a more compact design with high dynamics. Cable driven solutions are used to transmit the flexion/extension of the hip and knee joints, while a powerful ballscrew carries out the hip adduction/abduction. The design of this exoskeleton, named AUTONOMYO, follows the key specifications of being highly back-drivable and able to perform dynamic motions at low energy consumption. AUTONOMYO is capable to assist the user's balance by providing complementary torques at the hip and the knee. Results show that the projected level of assistance for sit-to-stand transition varies from 50% to 100% in function of the user's bodyweight and height while higher level of assistance are reached for walking and stairs climbing activities.
A strategy for computer-assisted mental practice in stroke rehabilitation.
Gaggioli, Andrea; Meneghini, Andrea; Morganti, Francesca; Alcaniz, Mariano; Riva, Giuseppe
2006-12-01
To investigate the technical and clinical viability of using computer-facilitated mental practice in the rehabilitation of upper-limb hemiparesis following stroke. A single-case study. Academic-affiliated rehabilitation center. A 46-year-old man with stable motor deficit of the upper right limb following subcortical ischemic stroke. Three computer-enhanced mental practice sessions per week at the rehabilitation center, in addition to usual physical therapy. A custom-made virtual reality system equipped with arm-tracking sensors was used to guide mental practice. The system was designed to superimpose over the (unseen) paretic arm a virtual reconstruction of the movement registered from the nonparetic arm. The laboratory intervention was followed by a 1-month home-rehabilitation program, making use of a portable display device. Pretreatment and posttreatment clinical assessment measures were the upper-extremity scale of the Fugl-Meyer Assessment of Sensorimotor Impairment and the Action Research Arm Test. Performance of the affected arm was evaluated using the healthy arm as the control condition. The patient's paretic limb improved after the first phase of intervention, with modest increases after home rehabilitation, as indicated by functional assessment scores and sensors data. Results suggest that technology-supported mental training is a feasible and potentially effective approach for improving motor skills after stroke.
Using virtual reality environment to facilitate training with advanced upper-limb prosthesis.
Resnik, Linda; Etter, Katherine; Klinger, Shana Lieberman; Kambe, Charles
2011-01-01
Technological advances in upper-limb prosthetic design offer dramatically increased possibilities for powered movement. The DEKA Arm system allows users 10 powered degrees of movement. Learning to control these movements by utilizing a set of motions that, in most instances, differ from those used to obtain the desired action prior to amputation is a challenge for users. In the Department of Veterans Affairs "Study to Optimize the DEKA Arm," we attempted to facilitate motor learning by using a virtual reality environment (VRE) program. This VRE program allows users to practice controlling an avatar using the controls designed to operate the DEKA Arm in the real world. In this article, we provide highlights from our experiences implementing VRE in training amputees to use the full DEKA Arm. This article discusses the use of VRE in amputee rehabilitation, describes the VRE system used with the DEKA Arm, describes VRE training, provides qualitative data from a case study of a subject, and provides recommendations for future research and implementation of VRE in amputee rehabilitation. Our experience has led us to believe that training with VRE is particularly valuable for upper-limb amputees who must master a large number of controls and for those amputees who need a structured learning environment because of cognitive deficits.
Neuromodulation of lower limb motor control in restorative neurology.
Minassian, Karen; Hofstoetter, Ursula; Tansey, Keith; Mayr, Winfried
2012-06-01
One consequence of central nervous system injury or disease is the impairment of neural control of movement, resulting in spasticity and paralysis. To enhance recovery, restorative neurology procedures modify altered, yet preserved nervous system function. This review focuses on functional electrical stimulation (FES) and spinal cord stimulation (SCS) that utilize remaining capabilities of the distal apparatus of spinal cord, peripheral nerves and muscles in upper motor neuron dysfunctions. FES for the immediate generation of lower limb movement along with current rehabilitative techniques is reviewed. The potential of SCS for controlling spinal spasticity and enhancing lower limb function in multiple sclerosis and spinal cord injury is discussed. The necessity for precise electrode placement and appropriate stimulation parameter settings to achieve therapeutic specificity is elaborated. This will lead to our human work of epidural and transcutaneous stimulation targeting the lumbar spinal cord for enhancing motor functions in spinal cord injured people, supplemented by pertinent human research of other investigators. We conclude that the concept of restorative neurology recently received new appreciation by accumulated evidence for locomotor circuits residing in the human spinal cord. Technological and clinical advancements need to follow for a major impact on the functional recovery in individuals with severe damage to their motor system. Copyright © 2012 Elsevier B.V. All rights reserved.
Lu, Elaine C; Wang, Rosalie H; Hebert, Debbie; Boger, Jennifer; Galea, Mary P; Mihailidis, Alex
2011-01-01
PURPOSE. Timely and adequate rehabilitation after a stroke is crucial to maximising recovery. A way of increasing treatment access could be through robots, which would aid therapists in providing post-stroke rehabilitation. This research sought to discover the needs and preferences of therapists with respect to a robot that focuses on upper limb rehabilitation. Understanding requirements for devices could help to increase integration into clinical practice. METHODS. An international online survey was distributed through professional organisations and e-mail list services to therapists. The survey contained 85 items covering topics such as therapist background and treatment approach, rehabilitation aims and robotic rehabilitation device attributes. RESULTS. Data were analysed for 233 respondents, most of whom were physiotherapists and occupational therapists from Australia, Canada and USA. Top attributes included: facilitating a variety of arm movements, being usable while seated, giving biofeedback to clients, having virtual activities specific to daily living, being useful in-home and having resistance adjustable to client needs. In addition, the device should cost under 6000 USD. CONCLUSIONS. Findings from this survey provide guidance for technology developers regarding therapists' specifications for a robotic device for upper limb rehabilitation. In addition, findings offer a better understanding of how acceptance of such devices may be facilitated.
Neuromodulation of lower limb motor control in restorative neurology
Minassian, Karen; Hofstoetter, Ursula; Tansey, Keith; Mayr, Winfried
2012-01-01
One consequence of central nervous system injury or disease is the impairment of neural control of movement, resulting in spasticity and paralysis. To enhance recovery, restorative neurology procedures modify altered, yet preserved nervous system function. This review focuses on functional electrical stimulation (FES) and spinal cord stimulation (SCS) that utilize remaining capabilities of the distal apparatus of spinal cord, peripheral nerves and muscles in upper motor neuron dysfunctions. FES for the immediate generation of lower limb movement along with current rehabilitative techniques is reviewed. The potential of SCS for controlling spinal spasticity and enhancing lower limb function in multiple sclerosis and spinal cord injury is discussed. The necessity for precise electrode placement and appropriate stimulation parameter settings to achieve therapeutic specificity is elaborated. This will lead to our human work of epidural and transcutaneous stimulation targeting the lumbar spinal cord for enhancing motor functions in spinal cord injured people, supplemented by pertinent human research of other investigators. We conclude that the concept of restorative neurology recently received new appreciation by accumulated evidence for locomotor circuits residing in the human spinal cord. Technological and clinical advancements need to follow for a major impact on the functional recovery in individuals with severe damage to their motor system. PMID:22464657
Photometric Properties of Network and Faculae Derived from HMI Data Compensated for Scattered Light
NASA Astrophysics Data System (ADS)
Criscuoli, Serena; Norton, Aimee; Whitney, Taylor
2017-10-01
We report on the photometric properties of faculae and network, as observed in full-disk, scattered-light-corrected images from the Helioseismic Magnetic Imager. We use a Lucy-Richardson deconvolution routine that corrects an image in less than one second. Faculae are distinguished from network through proximity to active regions. This is the first report that full-disk observations, including center-to-limb variations, reproduce the photometric properties of faculae and network observed previously only in sub-arcsecond-resolution; small field-of-view studies, I.e. that network, as defined by distance from active regions, exhibit higher photometric contrasts. Specifically, for magnetic flux values larger than approximately 300 G, the network is brighter than faculae and the contrast differences increase toward the limb, where the network contrast is about twice the facular one. For lower magnetic flux values, network appear darker than faculae. Contrary to reports from previous full-disk observations, we also found that network exhibits a higher center-to-limb variation. Our results are in agreement with reports from simulations that indicate magnetic flux alone is a poor proxy of the photometric properties of magnetic features. We estimate that the contribution of faculae and network to Total Solar Irradiance variability of the current Cycle 24 is overestimated by at least 11%, due to the photometric properties of network and faculae not being recognized as different. This estimate is specific to the method employed in this study to reconstruct irradiance variations, so caution should be paid when extending it to other techniques.
Unusual hand postures but not familiar tools show motor equivalence with precision grasping.
Tang, Rixin; Whitwell, Robert L; Goodale, Melvyn A
2016-06-01
A central question in sensorimotor control is whether or not actions performed with the hands and corresponding actions performed with tools share a common underlying motor plan, even though different muscles and effectors are engaged. There is certainly evidence that tools used to extend the reach of the limb can be incorporated into the body schema after training. But even so, it is not clear whether or not actions such as grasping with tools and grasping with the fingers share the same programming network, i.e. show 'motor equivalence'. Here we first show that feedback-appropriate motor programming for grasps with atypical hand postures readily transfers to stereotypical precision grasps. In stark contrast, however, we find no evidence for an analogous transfer of the programming for grasps using tools to the same stereotypical precision grasps. These findings have important implications for our understanding of body schema. Although the extension of the limb that is afforded by tool use may be incorporated into the body schema, the programming of a grasping movement made with tools appears to resist such incorporation. It could be the case that the proprioceptive signals from the limb can be easily updated to reflect the end of a tool held in the hand, but the motor programs and sensory signals associated with grasping with the thumb and finger cannot be easily adapted to control the opening and closing of a tool. Instead, new but well-practiced motor programs are put in place for tool use that do not exhibit motor equivalence with manual grasping. Copyright © 2016 Elsevier B.V. All rights reserved.
Three-Dimensional Morphology of a Coronal Prominence Cavity
NASA Technical Reports Server (NTRS)
Gibson, S. E.; Kucera, T. A.; Rastawicki, D.; Dove, J.; deToma, G.; Hao, J.; Hill, S.; Hudson, H. S.; Marque, C.; McIntosh, P. S.;
2010-01-01
We present a three-dimensional density model of coronal prominence cavities, and a morphological fit that has been tightly constrained by a uniquely well-observed cavity. Observations were obtained as part of an International Heliophysical Year campaign by instruments from a variety of space- and ground-based observatories, spanning wavelengths from radio to soft-X-ray to integrated white light. From these data it is clear that the prominence cavity is the limb manifestation of a longitudinally-extended polar-crown filament channel, and that the cavity is a region of low density relative to the surrounding corona. As a first step towards quantifying density and temperature from campaign spectroscopic data, we establish the three-dimensional morphology of the cavity. This is critical for taking line-of-sight projection effects into account, since cavities are not localized in the plane of the sky and the corona is optically thin. We have augmented a global coronal streamer model to include a tunnel-like cavity with elliptical cross-section and a Gaussian variation of height along the tunnel length. We have developed a semi-automated routine that fits ellipses to cross-sections of the cavity as it rotates past the solar limb, and have applied it to Extreme Ultraviolet Imager (EUVI) observations from the two Solar Terrestrial Relations Observatory (STEREO) spacecraft. This defines the morphological parameters of our model, from which we reproduce forward-modeled cavity observables. We find that cavity morphology and orientation, in combination with the viewpoints of the observing spacecraft, explains the observed variation in cavity visibility for the east vs. west limbs
Limb position sense, proprioceptive drift and muscle thixotropy at the human elbow joint
Tsay, A; Savage, G; Allen, T J; Proske, U
2014-01-01
These experiments on the human forearm are based on the hypothesis that drift in the perceived position of a limb over time can be explained by receptor adaptation. Limb position sense was measured in 39 blindfolded subjects using a forearm-matching task. A property of muscle, its thixotropy, a contraction history-dependent passive stiffness, was exploited to place muscle receptors of elbow muscles in a defined state. After the arm had been held flexed and elbow flexors contracted, we observed time-dependent changes in the perceived position of the reference arm by an average of 2.8° in the direction of elbow flexion over 30 s (Experiment 1). The direction of the drift reversed after the arm had been extended and elbow extensors contracted, with a mean shift of 3.5° over 30 s in the direction of elbow extension (Experiment 2). The time-dependent changes could be abolished by conditioning elbow flexors and extensors in the reference arm at the test angle, although this led to large position errors during matching (±10°), depending on how the indicator arm had been conditioned (Experiments 3 and 4). When slack was introduced in the elbow muscles of both arms, by shortening muscles after the conditioning contraction, matching errors became small and there was no drift in position sense (Experiments 5 and 6). These experiments argue for a receptor-based mechanism for proprioceptive drift and suggest that to align the two forearms, the brain monitors the difference between the afferent signals from the two arms. PMID:24665096
Truncating SLC5A7 mutations underlie a spectrum of dominant hereditary motor neuropathies
Salter, Claire G.; Beijer, Danique; Hardy, Holly; Barwick, Katy E.S.; Bower, Matthew; Mademan, Ines; De Jonghe, Peter; Deconinck, Tine; Russell, Mark A.; McEntagart, Meriel M.; Chioza, Barry A.; Blakely, Randy D.; Chilton, John K.; De Bleecker, Jan; Baets, Jonathan; Baple, Emma L.
2018-01-01
Objective To identify the genetic cause of disease in 2 previously unreported families with forms of distal hereditary motor neuropathies (dHMNs). Methods The first family comprises individuals affected by dHMN type V, which lacks the cardinal clinical feature of vocal cord paralysis characteristic of dHMN-VII observed in the second family. Next-generation sequencing was performed on the proband of each family. Variants were annotated and filtered, initially focusing on genes associated with neuropathy. Candidate variants were further investigated and confirmed by dideoxy sequence analysis and cosegregation studies. Thorough patient phenotyping was completed, comprising clinical history, examination, and neurologic investigation. Results dHMNs are a heterogeneous group of peripheral motor neuron disorders characterized by length-dependent neuropathy and progressive distal limb muscle weakness and wasting. We previously reported a dominant-negative frameshift mutation located in the concluding exon of the SLC5A7 gene encoding the choline transporter (CHT), leading to protein truncation, as the likely cause of dominantly-inherited dHMN-VII in an extended UK family. In this study, our genetic studies identified distinct heterozygous frameshift mutations located in the last coding exon of SLC5A7, predicted to result in the truncation of the CHT C-terminus, as the likely cause of the condition in each family. Conclusions This study corroborates C-terminal CHT truncation as a cause of autosomal dominant dHMN, confirming upper limb predominating over lower limb involvement, and broadening the clinical spectrum arising from CHT malfunction. PMID:29582019
Caimmi, Marco; Chiavenna, Andrea; Scano, Alessandro; Gasperini, Giulio; Giovanzana, Chiara; Molinari Tosatti, Lorenzo; Molteni, Franco
2017-06-01
Robotic rehabilitation is promising to promote function in stroke patients. The assist as needed training paradigm has shown to stimulate neuroplasticity but often cannot be used because stroke patients are too impaired to actively control the robot against gravity. To verify whether a rehabilitation intervention based on robot fully assisted reaching against gravity (RCH) and hand-to-mouth (HTM) can promote upper-limb function in chronic stroke. Cohort study. Chronic stroke outpatients referring to the robotic rehabilitation lab of a rehabilitation centre. Ten chronic stroke patients with mild to moderate upper-limb hemiparesis. Patients underwent 12 sessions (3 per week) of robotic treatment using an end-effector robot Every session consisted of 20 minutes each of RCH and HtM; movements were fully assisted, but patients were asked to try to actively participate. The Fugl-Meyer Assessment (FMA) was the primary outcome measure; Medical Research Council and Modified Ashworth Scale were the secondary outcome measures. All patients, but one, show functional improvements (FMA section A-D, mean increment 7.2±3.9 points, P<0.008). This preliminary study shows that a robotic intervention based on functional movements, fully assisted, can be effective in promoting function in chronic stroke patients. These results are promising considering the short time of the intervention (1 month) and the time from the stroke event, which was large (27±20 months). A larger study, comprehensive of objective instrumental measures, is necessary to confirm the results. This intervention could be extended even to subacute stroke and other neurological disorders.
Photometric Properties of Network and Faculae Derived from HMI Data Compensated for Scattered Light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Criscuoli, Serena; Whitney, Taylor; Norton, Aimee
We report on the photometric properties of faculae and network, as observed in full-disk, scattered-light-corrected images from the Helioseismic Magnetic Imager. We use a Lucy–Richardson deconvolution routine that corrects an image in less than one second. Faculae are distinguished from network through proximity to active regions. This is the first report that full-disk observations, including center-to-limb variations, reproduce the photometric properties of faculae and network observed previously only in sub-arcsecond-resolution; small field-of-view studies, i.e. that network, as defined by distance from active regions, exhibit higher photometric contrasts. Specifically, for magnetic flux values larger than approximately 300 G, the network ismore » brighter than faculae and the contrast differences increase toward the limb, where the network contrast is about twice the facular one. For lower magnetic flux values, network appear darker than faculae. Contrary to reports from previous full-disk observations, we also found that network exhibits a higher center-to-limb variation. Our results are in agreement with reports from simulations that indicate magnetic flux alone is a poor proxy of the photometric properties of magnetic features. We estimate that the contribution of faculae and network to Total Solar Irradiance variability of the current Cycle 24 is overestimated by at least 11%, due to the photometric properties of network and faculae not being recognized as different. This estimate is specific to the method employed in this study to reconstruct irradiance variations, so caution should be paid when extending it to other techniques.« less
Alexander, David E.; Gong, Enpu; Martin, Larry D.; Burnham, David A.; Falk, Amanda R.
2010-01-01
Fossils of the remarkable dromaeosaurid Microraptor gui and relatives clearly show well-developed flight feathers on the hind limbs as well as the front limbs. No modern vertebrate has hind limbs functioning as independent, fully developed wings; so, lacking a living example, little agreement exists on the functional morphology or likely flight configuration of the hindwing. Using a detailed reconstruction based on the actual skeleton of one individual, cast in the round, we developed light-weight, three-dimensional physical models and performed glide tests with anatomically reasonable hindwing configurations. Models were tested with hindwings abducted and extended laterally, as well as with a previously described biplane configuration. Although the hip joint requires the hindwing to have at least 20° of negative dihedral (anhedral), all configurations were quite stable gliders. Glide angles ranged from 3° to 21° with a mean estimated equilibrium angle of 13.7°, giving a lift to drag ratio of 4.1:1 and a lift coefficient of 0.64. The abducted hindwing model’s equilibrium glide speed corresponds to a glide speed in the living animal of 10.6 m·s−1. Although the biplane model glided almost as well as the other models, it was structurally deficient and required an unlikely weight distribution (very heavy head) for stable gliding. Our model with laterally abducted hindwings represents a biologically and aerodynamically reasonable configuration for this four-winged gliding animal. M. gui’s feathered hindwings, although effective for gliding, would have seriously hampered terrestrial locomotion. PMID:20133792
Ruecker, A; Uzun, H; Karanfil, T; Tsui, M T K; Chow, A T
2017-12-01
Coastal blackwater rivers, characterized by high concentrations of natural organic matter, are source water for millions of people in the southeastern US. In October 2015, large areas of coastal South Carolina were flooded by Hurricane Joaquin. This so-called "thousand-year" rainfall mobilized and flushed large amounts of terrestrial organic matter and associated pollutants (e.g. mercury) into source water, affecting water quality and safety of municipal water supply. To understand the dynamics of water quality and water treatability during this extreme flood, water samples were collected from Waccamaw River (a typical blackwater river in the southeastern US) during rising limb, peak discharge, falling limb, and base flow. Despite decreasing water flow after peak discharge, dissolved organic carbon (DOC) levels (increased by up to 125%), and formation potentials of trihalomethanes and haloacetic acids (increased by up to 150%) remained high for an extended period of time (>eight weeks after peak discharge), while variation in the N-nitrosodimethylamine (NDMA) FP was negligible. Coagulation with alum and ferric at optimal dosage significantly reduced concentrations of DOC by 51-76%, but up to 10 mg/L of DOC still remained in treated waters. For an extended period of time, elevated levels of THMs (71-448 μg/L) and HAAs (88-406 μg/L) were quantified in laboratory chlorination experiments under uniform formation conditions (UFC), exceeding the United States Environmental Protection Agency's (USEPA) maximum contaminant level of 80 and 60 μg/L, respectively. Results demonstrated that populations in coastal cities are at high risk with disinfection by-products (DBPs) under the changing climate. Copyright © 2017 Elsevier Ltd. All rights reserved.
Costa, L; Mantha, V R; Silva, A J; Fernandes, R J; Marinho, D A; Vilas-Boas, J P; Machado, L; Rouboa, A
2015-07-16
Computational fluid dynamics (CFD) plays an important role to quantify, understand and "observe" the water movements around the human body and its effects on drag (D). We aimed to investigate the flow effects around the swimmer and to compare the drag and drag coefficient (CD) values obtained from experiments (using cable velocimetry in a swimming pool) with those of CFD simulations for the two ventral gliding positions assumed during the breaststroke underwater cycle (with shoulders flexed and upper limbs extended above the head-GP1; with shoulders in neutral position and upper limbs extended along the trunk-GP2). Six well-trained breaststroke male swimmers (with reasonable homogeneity of body characteristics) participated in the experimental tests; afterwards a 3D swimmer model was created to fit within the limits of the sample body size profile. The standard k-ε turbulent model was used to simulate the fluid flow around the swimmer model. Velocity ranged from 1.30 to 1.70 m/s for GP1 and 1.10 to 1.50 m/s for GP2. Values found for GP1 and GP2 were lower for CFD than experimental ones. Nevertheless, both CFD and experimental drag/drag coefficient values displayed a tendency to jointly increase/decrease with velocity, except for GP2 CD where CFD and experimental values display opposite tendencies. Results suggest that CFD values obtained by single model approaches should be considered with caution due to small body shape and dimension differences to real swimmers. For better accuracy of CFD studies, realistic individual 3D models of swimmers are required, and specific kinematics respected. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hurst, Dale F; Read, William G; Vömel, Holger; Selkirk, Henry B; Rosenlof, Karen H; Davis, Sean M; Hall, Emrys G; Jordan, Allen F; Oltmans, Samuel J
2016-09-08
Balloon-borne frost point hygrometers (FPs) and the Aura Microwave Limb Sounder (MLS) provide high-quality vertical profile measurements of water vapor in the upper troposphere and lower stratosphere (UTLS). A previous comparison of stratospheric water vapor measurements by FPs and MLS over three sites - Boulder, Colorado (40.0° N); Hilo, Hawaii (19.7° N); and Lauder, New Zealand (45.0° S) - from August 2004 through December 2012 not only demonstrated agreement better than 1% between 68 and 26 hPa but also exposed statistically significant biases of 2 to 10% at 83 and 100 hPa (Hurst et al., 2014). A simple linear regression analysis of the FP-MLS differences revealed no significant long-term drifts between the two instruments. Here we extend the drift comparison to mid-2015 and add two FP sites - Lindenberg, Germany (52.2° N), and San José, Costa Rica (10.0° N) - that employ FPs of different manufacture and calibration for their water vapor soundings. The extended comparison period reveals that stratospheric FP and MLS measurements over four of the five sites have diverged at rates of 0.03 to 0.07 ppmv year -1 (0.6 to 1.5% year -1 ) from ~2010 to mid-2015. These rates are similar in magnitude to the 30-year (1980-2010) average growth rate of stratospheric water vapor (~ 1% year -1 ) measured by FPs over Boulder (Hurst et al., 2011). By mid-2015, the FP-MLS differences at some sites were large enough to exceed the combined accuracy estimates of the FP and MLS measurements.
Hurst, Dale F.; Read, William G.; Vömel, Holger; Selkirk, Henry B.; Rosenlof, Karen H.; Davis, Sean M.; Hall, Emrys G.; Jordan, Allen F.; Oltmans, Samuel J.
2017-01-01
Balloon-borne frost point hygrometers (FPs) and the Aura Microwave Limb Sounder (MLS) provide high-quality vertical profile measurements of water vapor in the upper troposphere and lower stratosphere (UTLS). A previous comparison of stratospheric water vapor measurements by FPs and MLS over three sites - Boulder, Colorado (40.0° N); Hilo, Hawaii (19.7° N); and Lauder, New Zealand (45.0° S) - from August 2004 through December 2012 not only demonstrated agreement better than 1% between 68 and 26 hPa but also exposed statistically significant biases of 2 to 10% at 83 and 100 hPa (Hurst et al., 2014). A simple linear regression analysis of the FP-MLS differences revealed no significant long-term drifts between the two instruments. Here we extend the drift comparison to mid-2015 and add two FP sites - Lindenberg, Germany (52.2° N), and San José, Costa Rica (10.0° N) - that employ FPs of different manufacture and calibration for their water vapor soundings. The extended comparison period reveals that stratospheric FP and MLS measurements over four of the five sites have diverged at rates of 0.03 to 0.07 ppmv year−1 (0.6 to 1.5% year−1) from ~2010 to mid-2015. These rates are similar in magnitude to the 30-year (1980–2010) average growth rate of stratospheric water vapor (~ 1% year−1) measured by FPs over Boulder (Hurst et al., 2011). By mid-2015, the FP–MLS differences at some sites were large enough to exceed the combined accuracy estimates of the FP and MLS measurements. PMID:28966694
NASA Astrophysics Data System (ADS)
Hurst, Dale F.; Read, William G.; Vömel, Holger; Selkirk, Henry B.; Rosenlof, Karen H.; Davis, Sean M.; Hall, Emrys G.; Jordan, Allen F.; Oltmans, Samuel J.
2016-09-01
Balloon-borne frost point hygrometers (FPs) and the Aura Microwave Limb Sounder (MLS) provide high-quality vertical profile measurements of water vapor in the upper troposphere and lower stratosphere (UTLS). A previous comparison of stratospheric water vapor measurements by FPs and MLS over three sites - Boulder, Colorado (40.0° N); Hilo, Hawaii (19.7° N); and Lauder, New Zealand (45.0° S) - from August 2004 through December 2012 not only demonstrated agreement better than 1 % between 68 and 26 hPa but also exposed statistically significant biases of 2 to 10 % at 83 and 100 hPa (Hurst et al., 2014). A simple linear regression analysis of the FP-MLS differences revealed no significant long-term drifts between the two instruments. Here we extend the drift comparison to mid-2015 and add two FP sites - Lindenberg, Germany (52.2° N), and San José, Costa Rica (10.0° N) - that employ FPs of different manufacture and calibration for their water vapor soundings. The extended comparison period reveals that stratospheric FP and MLS measurements over four of the five sites have diverged at rates of 0.03 to 0.07 ppmv year-1 (0.6 to 1.5 % year-1) from ˜ 2010 to mid-2015. These rates are similar in magnitude to the 30-year (1980-2010) average growth rate of stratospheric water vapor ( ˜ 1 % year-1) measured by FPs over Boulder (Hurst et al., 2011). By mid-2015, the FP-MLS differences at some sites were large enough to exceed the combined accuracy estimates of the FP and MLS measurements.
Performance Evaluation Methods for Assistive Robotic Technology
NASA Astrophysics Data System (ADS)
Tsui, Katherine M.; Feil-Seifer, David J.; Matarić, Maja J.; Yanco, Holly A.
Robots have been developed for several assistive technology domains, including intervention for Autism Spectrum Disorders, eldercare, and post-stroke rehabilitation. Assistive robots have also been used to promote independent living through the use of devices such as intelligent wheelchairs, assistive robotic arms, and external limb prostheses. Work in the broad field of assistive robotic technology can be divided into two major research phases: technology development, in which new devices, software, and interfaces are created; and clinical, in which assistive technology is applied to a given end-user population. Moving from technology development towards clinical applications is a significant challenge. Developing performance metrics for assistive robots poses a related set of challenges. In this paper, we survey several areas of assistive robotic technology in order to derive and demonstrate domain-specific means for evaluating the performance of such systems. We also present two case studies of applied performance measures and a discussion regarding the ubiquity of functional performance measures across the sampled domains. Finally, we present guidelines for incorporating human performance metrics into end-user evaluations of assistive robotic technologies.
ERIC Educational Resources Information Center
Zhang, Chun; Du, Jianxia; Sun, Li; Ding, Yi
2018-01-01
Technology has been quickly changing human interactions, traditional practices, and almost every aspect of our lives. It is important to maintain effective face-to-face communication and interactions between teachers and families. Nonetheless, technology and its tools can also extend and enhance family-teacher relationships and partnerships. This…
Robotic Technologies and Rehabilitation: New Tools for Stroke Patients' Therapy
Poli, Patrizia; Morone, Giovanni; Rosati, Giulio; Masiero, Stefano
2013-01-01
Introduction. The role of robotics in poststroke patients' rehabilitation has been investigated intensively. This paper presents the state-of-the-art and the possible future role of robotics in poststroke rehabilitation, for both upper and lower limbs. Materials and Methods. We performed a comprehensive search of PubMed, Cochrane, and PeDRO databases using as keywords “robot AND stroke AND rehabilitation.” Results and Discussion. In upper limb robotic rehabilitation, training seems to improve arm function in activities of daily living. In addition, electromechanical gait training after stroke seems to be effective. It is still unclear whether robot-assisted arm training may improve muscle strength, and which electromechanical gait-training device may be the most effective for walking training implementation. Conclusions. In the field of robotic technologies for stroke patients' rehabilitation we identified currently relevant growing points and areas timely for developing research. Among the growing points there is the development of new easily transportable, wearable devices that could improve rehabilitation also after discharge, in an outpatient or home-based setting. For developing research, efforts are being made to establish the ideal type of treatment, the length and amount of training protocol, and the patient's characteristics to be successfully enrolled to this treatment. PMID:24350244
Advances in neuroprosthetic learning and control.
Carmena, Jose M
2013-01-01
Significant progress has occurred in the field of brain-machine interfaces (BMI) since the first demonstrations with rodents, monkeys, and humans controlling different prosthetic devices directly with neural activity. This technology holds great potential to aid large numbers of people with neurological disorders. However, despite this initial enthusiasm and the plethora of available robotic technologies, existing neural interfaces cannot as yet master the control of prosthetic, paralyzed, or otherwise disabled limbs. Here I briefly discuss recent advances from our laboratory into the neural basis of BMIs that should lead to better prosthetic control and clinically viable solutions, as well as new insights into the neurobiology of action.
Seven Capital Devices for the Future of Stroke Rehabilitation
Iosa, M.; Morone, G.; Fusco, A.; Bragoni, M.; Coiro, P.; Multari, M.; Venturiero, V.; De Angelis, D.; Pratesi, L.; Paolucci, S.
2012-01-01
Stroke is the leading cause of long-term disability for adults in industrialized societies. Rehabilitation's efforts are tended to avoid long-term impairments, but, actually, the rehabilitative outcomes are still poor. Novel tools based on new technologies have been developed to improve the motor recovery. In this paper, we have taken into account seven promising technologies that can improve rehabilitation of patients with stroke in the early future: (1) robotic devices for lower and upper limb recovery, (2) brain computer interfaces, (3) noninvasive brain stimulators, (4) neuroprostheses, (5) wearable devices for quantitative human movement analysis, (6) virtual reality, and (7) tablet-pc used for neurorehabilitation. PMID:23304640
[Legal aspects of gene manipulation (author's transl)].
Weissauer, W
1979-11-02
The objects, aims and methods of research are protected from political misappropriation. But the freedom of research is limited by the clash with the legally protected third party, especially in the law of integrity of life and limb. To protect the environment from the (hypothetical) epidemiological dangers of gene technology the legislator has limited himself to measures by which he can obtain this aim with the least infringement of freedom of research. Gene technological intervention in human idioplasm is apparently not yet serious. Nevertheless the ethical and legal problems which arise form the point of view of human dignity from experiment with human genetic material should be discussed now.
Advances in Neuroprosthetic Learning and Control
Carmena, Jose M.
2013-01-01
Significant progress has occurred in the field of brain–machine interfaces (BMI) since the first demonstrations with rodents, monkeys, and humans controlling different prosthetic devices directly with neural activity. This technology holds great potential to aid large numbers of people with neurological disorders. However, despite this initial enthusiasm and the plethora of available robotic technologies, existing neural interfaces cannot as yet master the control of prosthetic, paralyzed, or otherwise disabled limbs. Here I briefly discuss recent advances from our laboratory into the neural basis of BMIs that should lead to better prosthetic control and clinically viable solutions, as well as new insights into the neurobiology of action. PMID:23700383
Three-dimensional Printing in Developing Countries
Ibrahim, Ahmed M. S.; Jose, Rod R.; Rabie, Amr N.; Gerstle, Theodore L.; Lee, Bernard T.
2015-01-01
Summary: The advent of 3-dimensional (3D) printing technology has facilitated the creation of customized objects. The lack of regulation in developing countries renders conventional means of addressing various healthcare issues challenging. 3D printing may provide a venue for addressing many of these concerns in an inexpensive and easily accessible fashion. These may potentially include the production of basic medical supplies, vaccination beads, laboratory equipment, and prosthetic limbs. As this technology continues to improve and prices are reduced, 3D printing has the potential ability to promote initiatives across the entire developing world, resulting in improved surgical care and providing a higher quality of healthcare to its residents. PMID:26301132
Three-dimensional Printing in Developing Countries.
Ibrahim, Ahmed M S; Jose, Rod R; Rabie, Amr N; Gerstle, Theodore L; Lee, Bernard T; Lin, Samuel J
2015-07-01
The advent of 3-dimensional (3D) printing technology has facilitated the creation of customized objects. The lack of regulation in developing countries renders conventional means of addressing various healthcare issues challenging. 3D printing may provide a venue for addressing many of these concerns in an inexpensive and easily accessible fashion. These may potentially include the production of basic medical supplies, vaccination beads, laboratory equipment, and prosthetic limbs. As this technology continues to improve and prices are reduced, 3D printing has the potential ability to promote initiatives across the entire developing world, resulting in improved surgical care and providing a higher quality of healthcare to its residents.
Lannin, Natasha A; Cusick, Anne; Hills, Caroline; Kinnear, Bianca; Vogel, Karin; Matthews, Kate; Bowring, Greg
2016-12-01
Assistive technologies have the potential to increase the amount of movement practice provided during inpatient stroke rehabilitation. The primary aim of this study was to investigate the feasibility of using the Saebo-Flex ™ device in a subacute stroke setting to increase task-specific practice for people with little or no active hand movement. The secondary aim was to collect preliminary data comparing hand/upper limb function between a control group that received usual rehabilitation and an intervention group that used, in addition, the Saebo-Flex ™ device. Nine inpatients (mean three months (median six weeks) post-stroke) participated in this feasibility study conducted in an Australian rehabilitation setting, using a randomised pre-test and post-test design with concealed allocation and blinded outcome assessment. In addition to usual rehabilitation, the intervention group received eight weeks of daily motor training using the Saebo-Flex ™ device. The control group received usual rehabilitation (task-specific motor training) only. Participants were assessed at baseline (pre-randomisation) and at the end of the eight-week study period. Feasibility was assessed with respect to ease of recruitment, application of the device, compliance with the treatment programme and safety. Secondary outcome measures included the Motor Assessment Scale (upper limb items), Box and Block Test, grip strength and the Stroke Impact Scale. Recruitment to the study was very slow because of the low number of patients with little or no active hand movement. Otherwise, the study was feasible in terms of being able to apply the Saebo-Flex ™ device and compliance with the treatment programme. There were no adverse events, and a greater amount of upper limb rehabilitation was provided to the intervention group. While there were trends in favour of the intervention group, particularly for dexterity, no between-group differences were seen for any of the secondary outcomes. This pilot feasibility study showed that the use of assistive technology, specifically the Saebo-Flex ™ device, could be successfully used in a sample of stroke patients with little or no active hand movement. However, recruitment to the trial was very slow. The use of the Saebo-Flex TM device had variable results on outcomes, with some positive trends seen in hand function, particularly dexterity. © 2016 Occupational Therapy Australia.
A review of supernumerary and absent limbs and digits of the upper limb.
Klaassen, Zachary; Choi, Monica; Musselman, Ruth; Eapen, Deborah; Tubbs, R Shane; Loukas, Marios
2012-03-01
For years people have been enamored by anomalies of the human limbs, particularly supernumerary and absent limbs and digits. Historically, there are a number of examples of such anomalies, including royal families of ancient Chaldea, tribes from Arabia, and examples from across nineteenth century Europe. The development of the upper limbs in a growing embryo is still being elucidated with the recent advent of homeobox genes, but researchers agree that upper limbs develop between stages 12-23 through a complex embryological process. Maternal thalidomide intake during limb development is known to cause limb reduction and subsequent amelia or phocomelia. Additionally, a number of clinical reports have illustrated different limb anomaly cases, with each situation unique in phenotype and developmental abnormality. Supernumerary and absent limbs and digits are not unique to humans, and a number of animal cases have also been reported. This review of the literature illustrates the historical, anatomical, and clinical aspects of supernumerary and absent limbs and digits for the upper limb.
ERIC Educational Resources Information Center
Desmond, Deirdre M.; MacLachlan, Malcolm
2010-01-01
This study aims to describe the prevalence and characteristics of phantom limb pain and residual limb pain after upper limb amputation. One-hundred and forty-one participants (139 males; mean age 74.8 years; mean time since amputation 50.1 years) completed a self-report questionnaire assessing residual and phantom limb pain experience. Prevalence…
On-Command Force and Torque Impeding Devices (OC-FTID) Using ERF
NASA Technical Reports Server (NTRS)
Bar-Cohen, Yoseph; Badescu, Mircea; Sherrit, Stewart
2014-01-01
Various machines have been developed to address the need for countermeasures of bone and muscle deterioration when humans operate over extended time in space. Even though these machines are in use, each of them has many limitations that need to be addressed in an effort to prepare for human missions to distant bodies in the solar system. An exercise exoskeleton was conceived that performs on-demand resistivity by inducing force and torque impedance via ElectroRheological Fluid (ERF). The resistive elements consist of pistons that are moving inside ERF-filled cylinders or a donut-shaped cavity, and the fluid flows through the piston when the piston is moved. Tests of the operation of ERF against load showed the feasibility of this approach. ERF properties of high yield stress, low current density, and fast response (less than one millisecond) offer essential characteristics for the construction of the exoskeleton. ERFs can apply very high electrically controlled resistive forces or torque while their size (weight and geometric parameters) can be very small. Their long life and ability to function in a wide temperature range (from -40 to 200 C) allows for their use in extreme environments. ERFs are also nonabrasive, non-toxic, and nonpolluting (meet health and safety regulations). The technology is applicable as a compact exercise machine for astronauts' countermeasure of microgravity, an exercise machine for sport, or as a device for rehabilitation of patients with limb issues.
Cassini limb images of hazes in Saturn’s northern hemisphere
NASA Astrophysics Data System (ADS)
Sanchez-Lavega, Agustin M.; Garcia, Daniel; del Rio-Gaztelurrutia, Teresa; Garcia-Muñoz, Antonio; Perez-Hoyos, Santiago; Hueso, Ricardo
2017-10-01
We have used high resolution Cassini ISS images of the limb of Saturn to study the vertical distribution, altitude location, thickness and optical properties of the haze layers in the northern hemisphere (1°S to 82°N) in 2013 and 2015. The images cover an ample spectral range from the ultraviolet (UV1 filter, 264 nm) to the near infrared (CB3 filter, 938 nm) including methane absorption bands at 619 nm, 724 nm and 890 nm. Spatial resolution ranges from 1.6 to 13 km/pixel depending on wavelength and latitude. Three latitude bands were selected for the analysis according to the background zonal wind profile measured at cloud level and known dynamical activity: (a) North Polar Region encompassing the Hexagon latitude (74°N) (b) Mid-latitudes (45°N-52°N), and (3) Equator (1°N-3°S). The best defined haze structures and most extended haze layers were found at the latitude of the Hexagon. Up to 6-8 haze layers extending up to 400 km in altitude above clouds (in the pressure range from about 0.7 bar to 0.1 mbar) were detected. The vertical thickness of the layers is in the range 3-15 km compared to the scale height which is about 40 km. The spectral reflectivity is relatively uniform between the layers in the blue and red continuum wavelengths coming from the backward light scattering from the haze particles, while the brightness in the methane bands (relative to red continuum) and in the ultraviolet shows the effects of methane absorption and Rayleigh scattering by the gas, respectively. At mid-latitudes 3-4 haze layers are found spanning up to altitudes 200 km above the clouds. At the Equator 5-6 layers are found extending up to altitudes 250 km above the clouds (up to 2 mbar in pressure level) in a region of great dynamical interest because of the particular structure of the zonal winds and their known oscillations. We comment on the possible nature of the haze layers on the basis of condensing species and photochemistry.
Davies, Richard John; Parker, Jack; McCullagh, Paul; Zheng, Huiru; Nugent, Chris; Black, Norman David; Mawson, Susan
2016-11-08
In the United Kingdom, stroke is the single largest cause of adult disability and results in a cost to the economy of £8.9 billion per annum. Service needs are currently not being met; therefore, initiatives that focus on patient-centered care that promote long-term self-management for chronic conditions should be at the forefront of service redesign. The use of innovative technologies and the ability to apply these effectively to promote behavior change are paramount in meeting the current challenges. Our objective was to gain a deeper insight into the impact of innovative technologies in support of home-based, self-managed rehabilitation for stroke survivors. An intervention of daily walks can assist with improving lower limb motor function, and this can be measured by using technology. This paper focuses on assessing the usage of self-management technologies on poststroke survivors while undergoing rehabilitation at home. A realist evaluation of a personalized self-management rehabilitation system was undertaken in the homes of stroke survivors (N=5) over a period of approximately two months. Context, mechanisms, and outcomes were developed and explored using theories relating to motor recovery. Participants were encouraged to self-manage their daily walking activity; this was achieved through goal setting and motivational feedback. Gait data were collected and analyzed to produce metrics such as speed, heel strikes, and symmetry. This was achieved using a "smart insole" to facilitate measurement of walking activities in a free-living, nonrestrictive environment. Initial findings indicated that 4 out of 5 participants performed better during the second half of the evaluation. Performance increase was evident through improved heel strikes on participants' affected limb. Additionally, increase in performance in relation to speed was also evident for all 5 participants. A common strategy emerged across all but one participant as symmetry performance was sacrificed in favor of improved heel strikes. This paper evaluates compliance and intensity of use. Our findings suggested that 4 out of the 5 participants improved their ability to heel strike on their affected limb. All participants showed improvements in their speed of gait measured in steps per minute with an average increase of 9.8% during the rehabilitation program. Performance in relation to symmetry showed an 8.5% average decline across participants, although 1 participant improved by 4%. Context, mechanism, and outcomes indicated that dual motor learning and compensatory strategies were deployed by the participants. ©Richard John Davies, Jack Parker, Paul McCullagh, Huiru Zheng, Chris Nugent, Norman David Black, Susan Mawson. Originally published in JMIR Rehabilitation and Assistive Technology (http://rehab.jmir.org), 08.11.2016.
Be the Technology: Redefining Technology Integration in Classrooms.
ERIC Educational Resources Information Center
Mills, Steven C.; Tincher, Robert C.
A technology professional development initiative was launched in a school district with the goal of extending technology use in the classroom. For teachers to teach expertly, the aim was for them to "be the technology" by modeling technology use in the classroom, applying technology across the curriculum, applying technology to…
Chronic pain associated with upper-limb loss.
Hanley, Marisol A; Ehde, Dawn M; Jensen, Mark; Czerniecki, Joseph; Smith, Douglas G; Robinson, Lawrence R
2009-09-01
To describe the prevalence, intensity, and functional impact of the following types of pain associated with upper-limb loss: phantom limb, residual limb, back, neck, and nonamputated-limb pain. Cross-sectional survey; 104 respondents with upper-limb loss at least 6 months postamputation completed measures of pain intensity, interference, disability, and health-related quality-of-life. Nearly all (90%) of the respondents reported pain, with 76% reporting more than one pain type. Phantom-limb pain and residual-limb pain were the most prevalent (79% and 71%, respectively), followed by back (52%), neck (43%), and nonamputated-limb pain (33%). Although nonamputated-limb pain was least prevalent, it was reported to cause the highest levels of interference and pain-related disability days. Self-reported quality-of-life was significantly lower for individuals with each type of pain compared with those without any pain. Age, time since amputation, and cause of amputation were not associated with pain. In addition to pain in the phantom and residual limb, back, neck, and nonamputated-limb pain are also common after upper-limb loss. All of these pain types are associated with significant disability and activity interference for some individuals, suggesting that assessment of multiple pain types in persons with upper-limb amputation may be important.
Goodrich, Zachary J; Norby, Bo; Eichelberger, Bunita M; Friedeck, Wade O; Callis, Hollye N; Hulse, Don A; Kerwin, Sharon C; Fox, Derek B; Saunders, W Brian
2014-10-01
To report thoracic limb alignment values in healthy dogs; to determine if limb alignment values are significantly different when obtained from standing versus recumbent radiographic projections. Prospective cross-sectional study. Labrador Retrievers (n = 45) >15 months of age. Standing and recumbent radiographs were obtained and limb montages were randomized before analysis by a single investigator blinded to dog, limb, and limb position. Twelve limb alignment values were determined using the CORA methodology. Measurements were performed in triplicate and intra-observer variability was evaluated by intra-class correlation coefficient (ICC). Limb alignment values were reported as mean ± SD and 95% confidence intervals. Linear mixed models were used to determine if significant associations existed between limb alignment values and limb, limb position, gender, age, weight, and body condition score. There were significant differences in standing and recumbent limb alignment values for all values except elbow mechanical axis deviation (eMAD). Limb, gender, age, body weight, and body condition score had no effect. ICC values ranged from 0.522 to 0.758, indicating moderate to substantial agreement for repeated measurements by a single investigator. Limb alignment values are significantly different when determined from standing versus recumbent radiographs in healthy Labrador Retrievers. © Copyright 2014 by The American College of Veterinary Surgeons.
NASA Astrophysics Data System (ADS)
Woiwode, Wolfgang; Oelhaf, Hermann; Dörnbrack, Andreas; Bramberger, Martina; Diekmann, Christopher; Friedl-Vallon, Felix; Höpfner, Michael; Hoor, Peter; Johansson, Sören; Krause, Jens; Kunkel, Daniel; Orphal, Johannes; Preusse, Peter; Ruhnke, Roland; Schlage, Romy; Schröter, Jennifer; Sinnhuber, Björn-Martin; Ungermann, Jörn; Zahn, Andreas
2017-04-01
Tropopause folds are known of enabling efficient exchange of trace constituents between the stratosphere and troposphere. In particular, the modification of the vertical distributions of radiatively important H2O and other reactive trace gases associated with tropopause folds is relevant for accurate model simulations of the upper troposphere and lower stratosphere composition. During the POLSTRACC/GW-LCYCLE/SALSA flight on 12 January 2016, the HALO (High Altitude LOng range) aircraft crossed twice an extended tropopause fold in the vicinity of the Arctic polar vortex. At the same time, the ECMWF operational analysis shows that the meteorological scenario probed above Italy was accompanied by wide-spread gravity wave activity induced by north-westerly winds. Using high spectral resolution limb-observations by the GLORIA (Gimballed Limb Observer for Radiance Imaging of the Atmosphere) spectrometer aboard HALO and associated observations, we investigate the vertical distributions of H2O, O3, temperature, and associated parameters across the tropopause fold. In combination with a high-resolution simulation by the ICON-ART (ICOsahedral Nonhydrostatic- Aerosol and Reactive Trace gases) model, we search for indications for irreversible trace gas exchange between the stratosphere and troposphere and the potential influence of gravity waves.
Prontera, Paolo; Garelli, Emanuela; Isidori, Ilenia; Mencarelli, Amedea; Carando, Adriana; Silengo, Margherita Cirillo; Donti, Emilio
2011-11-01
Acro-dermato-ungual-lacrimal-tooth (ADULT) syndrome is a rare condition belonging to the group of ectodermal dysplasias caused by TP63 mutations. Its clinical phenotype is similar to ectrodactyly-ectodermal dysplasia-cleft lip/palate (EEC) and limb-mammary syndrome (LMS), and differs from these disorders mainly by the absence of cleft lip and/or palate. We report on a 39-year-old patient who was found to be heterozygous for a c.401G > T (p.Gly134Val) de novo mutation of TP63. This patient had the ADULT phenotype associated with cleft palate. Our findings, rather than extend the clinical spectrum of ADULT syndrome, suggest that cleft palate can no longer be considered an element for differential diagnosis for ADULT, EEC, and LMS. Our data, added to other reports on overlapping phenotypes, support the combining of these three phenotypes into a unique entity that we propose to call "ELA syndrome," which is an acronym of ectrodactyly-ectodermal dysplasia-cleft lip and palate, limb-mammary, and ADULT syndromes. Copyright © 2011 Wiley Periodicals, Inc.
Cheng, Yu-Wei; Tan, Christopher A; Minor, Agata; Arndt, Kelly; Wysinger, Latrice; Grange, Dorothy K; Kozel, Beth A; Robin, Nathaniel H; Waggoner, Darrel; Fitzpatrick, Carrie; Das, Soma; Del Gaudio, Daniela
2014-03-01
Cornelia de Lange syndrome (CdLS) is a genetically heterogeneous disorder characterized by growth retardation, intellectual disability, upper limb abnormalities, hirsutism, and characteristic facial features. In this study we explored the occurrence of intragenic NIPBL copy number variations (CNVs) in a cohort of 510 NIPBL sequence-negative patients with suspected CdLS. Copy number analysis was performed by custom exon-targeted oligonucleotide array-comparative genomic hybridization and/or MLPA. Whole-genome SNP array was used to further characterize rearrangements extending beyond the NIPBL gene. We identified NIPBL CNVs in 13 patients (2.5%) including one intragenic duplication and a deletion in mosaic state. Breakpoint sequences in two patients provided further evidence of a microhomology-mediated replicative mechanism as a potential predominant contributor to CNVs in NIPBL. Patients for whom clinical information was available share classical CdLS features including craniofacial and limb defects. Our experience in studying the frequency of NIBPL CNVs in the largest series of patients to date widens the mutational spectrum of NIPBL and emphasizes the clinical utility of performing NIPBL deletion/duplication analysis in patients with CdLS.
ERIC Educational Resources Information Center
Teo, T.; Lee, C. B.; Chai, C. S.
2008-01-01
Computers are increasingly widespread, influencing many aspects of our social and work lives. As we move into a technology-based society, it is important that classroom experiences with computers are made available for all students. The purpose of this study is to examine pre-service teachers' attitudes towards computers. This study extends the…
ERIC Educational Resources Information Center
Domingo, Myrrh
2012-01-01
In our contemporary society, digital texts circulate more readily and extend beyond page-bound formats to include interactive representations such as online newsprint with hyperlinks to audio and video files. This is to say that multimodality combined with digital technologies extends grammar to include voice, visual, and music, among other modes…
Studying Upper-Limb Kinematics Using Inertial Sensors Embedded in Mobile Phones.
Roldan-Jimenez, Cristina; Cuesta-Vargas, Antonio; Bennett, Paul
2015-05-20
In recent years, there has been a great interest in analyzing upper-limb kinematics. Inertial measurement with mobile phones is a convenient and portable analysis method for studying humerus kinematics in terms of angular mobility and linear acceleration. The aim of this analysis was to study upper-limb kinematics via mobile phones through six physical properties that correspond to angular mobility and acceleration in the three axes of space. This cross-sectional study recruited healthy young adult subjects. Humerus kinematics was studied in 10 young adults with the iPhone4. They performed flexion and abduction analytical tasks. Mobility angle and lineal acceleration in each of its axes (yaw, pitch, and roll) were obtained with the iPhone4. This device was placed on the right half of the body of each subject, in the middle third of the humerus, slightly posterior. Descriptive statistics were calculated. Descriptive graphics of analytical tasks performed were obtained. The biggest range of motion was found in pitch angle, and the biggest acceleration was found in the y-axis in both analytical tasks. Focusing on tridimensional kinematics, bigger range of motion and acceleration was found in abduction (209.69 degrees and 23.31 degrees per second respectively). Also, very strong correlation was found between angular mobility and linear acceleration in abduction (r=.845) and flexion (r=.860). The use of an iPhone for humerus tridimensional kinematics is feasible. This supports use of the mobile phone as a device to analyze upper-limb kinematics and to facilitate the evaluation of the patient. ©Cristina Roldan-Jimenez, Antonio Cuesta-Vargas, Paul Bennett. Originally published in JMIR Rehabilitation and Assistive Technology (http://rehab.jmir.org), 20.05.2015.
2018-01-01
Use of additive manufacturing is growing rapidly in the orthotics field. This technology allows orthotics to be designed directly on digital scans of limbs. However, little information is available about scanners and 3D scans. The aim of this study is to look at the agreement between manual measurements, high-level and low-cost handheld 3D scanners. We took two manual measurements and three 3D scans with each scanner from 14 lower limbs. The lower limbs were divided into 17 sections of 30mm each from 180mm above the mid-patella to 300mm below. Time to record and to process the three 3D scans for scanners methods were compared with Student t-test while Bland-Altman plots were used to study agreement between circumferences of each section from the three methods. The record time was 97s shorter with high-level scanner than with the low-cost (p = .02) while the process time was nine times quicker with the low-cost scanner (p < .01). An overestimation of 2.5mm was found in high-level scanner compared to manual measurement, but with a better repeatability between measurements. The low-cost scanner tended to overestimate the circumferences from 0.1% to 1.5%, overestimation being greater for smaller circumferences. In conclusion, 3D scanners provide more information about the shape of the lower limb, but the reliability depends on the 3D scanner and the size of the scanned segment. Low-cost scanners could be useful for clinicians because of the simple and fast process, but attention should be focused on accuracy, which depends on the scanned body segment. PMID:29320560
Macintosh, Alison A; Pinhasi, Ron; Stock, Jay T
2014-01-01
Humeral morphology has been shown to reflect, in part, habitual manipulative behaviors in humans. Among Central European agricultural populations, long-term social change, increasing task specialization, and technological innovation all had the potential to impact patterns of habitual activity and upper limb asymmetry. However, systematic temporal change in the skeletal morphology of agricultural populations in this region has not been well-characterized. This study investigates diachronic patterns in humeral biomechanical properties and lengths among 174 adult Central European agriculturalists through the first ∼ 5400 years of farming in the region. Greater asymmetry in biomechanical properties was expected to accompany the introduction of metallurgy, particularly in males, while upper limb loading patterns were expected to be more similar between the Bronze and Iron Ages. Results revealed a divergence in the lateralization of upper limb biomechanical properties by sex between the Early/Middle Neolithic and Early/Middle Bronze Age. Neolithic females had significantly more variable properties than males in both humeri, while Bronze Age female properties became homogeneous and very symmetrical relative to the right-biased lateralization of contemporaneous males. The Bronze Age to Iron Age transition was associated with morphological change among females, with a significant increase in right-biased asymmetry and a concomitant reduction in sexual dimorphism. Relative to biomechanical properties, humeral length variation and asymmetry were low though some significant sexual dimorphism and temporal change was found. It was among females that the lateralization of humeral biomechanical properties, and variation within them, changed most profoundly through time. This suggests that the introduction of the ard and plow, metallurgical innovation, task specialization, and socioeconomic change through ∼ 5400 years of agriculture impacted upper limb loading in Central European women to a greater extent than men.
2012-01-01
Background Novel stroke rehabilitation techniques that employ electrical stimulation (ES) and robotic technologies are effective in reducing upper limb impairments. ES is most effective when it is applied to support the patients’ voluntary effort; however, current systems fail to fully exploit this connection. This study builds on previous work using advanced ES controllers, and aims to investigate the feasibility of Stimulation Assistance through Iterative Learning (SAIL), a novel upper limb stroke rehabilitation system which utilises robotic support, ES, and voluntary effort. Methods Five hemiparetic, chronic stroke participants with impaired upper limb function attended 18, 1 hour intervention sessions. Participants completed virtual reality tracking tasks whereby they moved their impaired arm to follow a slowly moving sphere along a specified trajectory. To do this, the participants’ arm was supported by a robot. ES, mediated by advanced iterative learning control (ILC) algorithms, was applied to the triceps and anterior deltoid muscles. Each movement was repeated 6 times and ILC adjusted the amount of stimulation applied on each trial to improve accuracy and maximise voluntary effort. Participants completed clinical assessments (Fugl-Meyer, Action Research Arm Test) at baseline and post-intervention, as well as unassisted tracking tasks at the beginning and end of each intervention session. Data were analysed using t-tests and linear regression. Results From baseline to post-intervention, Fugl-Meyer scores improved, assisted and unassisted tracking performance improved, and the amount of ES required to assist tracking reduced. Conclusions The concept of minimising support from ES using ILC algorithms was demonstrated. The positive results are promising with respect to reducing upper limb impairments following stroke, however, a larger study is required to confirm this. PMID:22676920
Dessery, Yoann; Pallari, Jari
2018-01-01
Use of additive manufacturing is growing rapidly in the orthotics field. This technology allows orthotics to be designed directly on digital scans of limbs. However, little information is available about scanners and 3D scans. The aim of this study is to look at the agreement between manual measurements, high-level and low-cost handheld 3D scanners. We took two manual measurements and three 3D scans with each scanner from 14 lower limbs. The lower limbs were divided into 17 sections of 30mm each from 180mm above the mid-patella to 300mm below. Time to record and to process the three 3D scans for scanners methods were compared with Student t-test while Bland-Altman plots were used to study agreement between circumferences of each section from the three methods. The record time was 97s shorter with high-level scanner than with the low-cost (p = .02) while the process time was nine times quicker with the low-cost scanner (p < .01). An overestimation of 2.5mm was found in high-level scanner compared to manual measurement, but with a better repeatability between measurements. The low-cost scanner tended to overestimate the circumferences from 0.1% to 1.5%, overestimation being greater for smaller circumferences. In conclusion, 3D scanners provide more information about the shape of the lower limb, but the reliability depends on the 3D scanner and the size of the scanned segment. Low-cost scanners could be useful for clinicians because of the simple and fast process, but attention should be focused on accuracy, which depends on the scanned body segment.
Meadmore, Katie L; Hughes, Ann-Marie; Freeman, Chris T; Cai, Zhonglun; Tong, Daisy; Burridge, Jane H; Rogers, Eric
2012-06-07
Novel stroke rehabilitation techniques that employ electrical stimulation (ES) and robotic technologies are effective in reducing upper limb impairments. ES is most effective when it is applied to support the patients' voluntary effort; however, current systems fail to fully exploit this connection. This study builds on previous work using advanced ES controllers, and aims to investigate the feasibility of Stimulation Assistance through Iterative Learning (SAIL), a novel upper limb stroke rehabilitation system which utilises robotic support, ES, and voluntary effort. Five hemiparetic, chronic stroke participants with impaired upper limb function attended 18, 1 hour intervention sessions. Participants completed virtual reality tracking tasks whereby they moved their impaired arm to follow a slowly moving sphere along a specified trajectory. To do this, the participants' arm was supported by a robot. ES, mediated by advanced iterative learning control (ILC) algorithms, was applied to the triceps and anterior deltoid muscles. Each movement was repeated 6 times and ILC adjusted the amount of stimulation applied on each trial to improve accuracy and maximise voluntary effort. Participants completed clinical assessments (Fugl-Meyer, Action Research Arm Test) at baseline and post-intervention, as well as unassisted tracking tasks at the beginning and end of each intervention session. Data were analysed using t-tests and linear regression. From baseline to post-intervention, Fugl-Meyer scores improved, assisted and unassisted tracking performance improved, and the amount of ES required to assist tracking reduced. The concept of minimising support from ES using ILC algorithms was demonstrated. The positive results are promising with respect to reducing upper limb impairments following stroke, however, a larger study is required to confirm this.
Neural pathways mediating cross education of motor function
Ruddy, Kathy L.; Carson, Richard G.
2013-01-01
Cross education is the process whereby training of one limb gives rise to enhancements in the performance of the opposite, untrained limb. Despite interest in this phenomenon having been sustained for more than a century, a comprehensive explanation of the mediating neural mechanisms remains elusive. With new evidence emerging that cross education may have therapeutic utility, the need to provide a principled evidential basis upon which to design interventions becomes ever more pressing. Generally, mechanistic accounts of cross education align with one of two explanatory frameworks. Models of the “cross activation” variety encapsulate the observation that unilateral execution of a movement task gives rise to bilateral increases in corticospinal excitability. The related conjecture is that such distributed activity, when present during unilateral practice, leads to simultaneous adaptations in neural circuits that project to the muscles of the untrained limb, thus facilitating subsequent performance of the task. Alternatively, “bilateral access” models entail that motor engrams formed during unilateral practice, may subsequently be utilized bilaterally—that is, by the neural circuitry that constitutes the control centers for movements of both limbs. At present there is a paucity of direct evidence that allows the corresponding neural processes to be delineated, or their relative contributions in different task contexts to be ascertained. In the current review we seek to synthesize and assimilate the fragmentary information that is available, including consideration of knowledge that has emerged as a result of technological advances in structural and functional brain imaging. An emphasis upon task dependency is maintained throughout, the conviction being that the neural mechanisms that mediate cross education may only be understood in this context. PMID:23908616
Parker, Jack; McCullagh, Paul; Zheng, Huiru; Nugent, Chris; Black, Norman David; Mawson, Susan
2016-01-01
Background In the United Kingdom, stroke is the single largest cause of adult disability and results in a cost to the economy of £8.9 billion per annum. Service needs are currently not being met; therefore, initiatives that focus on patient-centered care that promote long-term self-management for chronic conditions should be at the forefront of service redesign. The use of innovative technologies and the ability to apply these effectively to promote behavior change are paramount in meeting the current challenges. Objective Our objective was to gain a deeper insight into the impact of innovative technologies in support of home-based, self-managed rehabilitation for stroke survivors. An intervention of daily walks can assist with improving lower limb motor function, and this can be measured by using technology. This paper focuses on assessing the usage of self-management technologies on poststroke survivors while undergoing rehabilitation at home. Methods A realist evaluation of a personalized self-management rehabilitation system was undertaken in the homes of stroke survivors (N=5) over a period of approximately two months. Context, mechanisms, and outcomes were developed and explored using theories relating to motor recovery. Participants were encouraged to self-manage their daily walking activity; this was achieved through goal setting and motivational feedback. Gait data were collected and analyzed to produce metrics such as speed, heel strikes, and symmetry. This was achieved using a “smart insole” to facilitate measurement of walking activities in a free-living, nonrestrictive environment. Results Initial findings indicated that 4 out of 5 participants performed better during the second half of the evaluation. Performance increase was evident through improved heel strikes on participants’ affected limb. Additionally, increase in performance in relation to speed was also evident for all 5 participants. A common strategy emerged across all but one participant as symmetry performance was sacrificed in favor of improved heel strikes. This paper evaluates compliance and intensity of use. Conclusion Our findings suggested that 4 out of the 5 participants improved their ability to heel strike on their affected limb. All participants showed improvements in their speed of gait measured in steps per minute with an average increase of 9.8% during the rehabilitation program. Performance in relation to symmetry showed an 8.5% average decline across participants, although 1 participant improved by 4%. Context, mechanism, and outcomes indicated that dual motor learning and compensatory strategies were deployed by the participants. PMID:28582260
1982-06-16
Technology Intergration (AFTI) Pro- gram, (2) a nonmetallic composite helicopter fuselage, and (3) a new initiative to develop Short Take-Off and...range of passive sonobuoys is being extended and the performance of a high gain extended life deployed horizontal line array is being investigated
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farrell, John T; Kelly, Kenneth J; Duran, Adam W
Range-extended electric vehicle (EV) technology can be a viable option for reducing fuel consumption from medium-duty (MD) and heavy-duty (HD) engines by approximately 50 percent or more. Such engines have wide variations in use and duty cycles, however, and identifying the vocations/duty cycles most suitable for range-extended applications is vital for maximizing the potential benefits. This presentation provides information about NREL's research on range-extended EV technologies, with a focus on NREL's real-world data collection and analysis approach to identifying the vocations/duty cycles best suited for range-extender applications and to help guide related powertrain optimization and design requirements. The presentation alsomore » details NREL's drive cycle development process as it pertains to package delivery applications.« less
Mullaji, Arun B; Shah, Siddharth; Shetty, Gautam M
2017-01-01
Background and purpose — Medial unicompartmental knee arthroplasty (UKA) is undertaken in patients with a passively correctable varus deformity. We investigated whether restoration of natural soft tissue tension would result in a lower limb alignment similar to that of the contralateral unaffected lower limb after mobile-bearing medial UKA. Patients and methods — In this retrospective study, hip-knee-ankle (HKA) angle, position of the weight-bearing axis (WBA), and knee joint line obliquity (KJLO) after mobile-bearing medial UKA was compared with that of the unaffected (clinically and radiologically) contralateral lower limb in 123 patients. Results — Postoperatively, HKA angle was restored to within ±3° of the contralateral lower limb in 87% of the patients and the WBA passed within ±1 Kennedy and White’s tibial zone of the unaffected contralateral lower limb in 95% of the patients. The mean KJLO in the operated limbs was not significantly different from that in the unaffected lower limbs (p = 0.07) and the KJLO in the operated limb was restored to within ±3° of that in the contralateral lower limb in 96% of the patients. Interpretation — Lower limb alignment and knee joint line obliquity after mobile-bearing medial UKA were comparable to that of the unaffected contralateral limb in most patients. Comparison with the contralateral unaffected lower limb is a reliable method for evaluation and validation of limb mechanical alignment after mobile-bearing medial UKA. PMID:27794622
Agency over Phantom Limb Enhanced by Short-Term Mirror Therapy
Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi
2017-01-01
Most amputees experience phantom limb, whereby they feel that the amputated limb is still present. In some cases, these experiences include pain that can be alleviated by “mirror therapy.” Mirror therapy consists of superimposing a mirrored image of the moving intact limb onto the phantom limb. This therapy provides a closed loop between the motor command to the amputated limb and its predicted visual feedback. This loop is also involved in the sense of agency, a feeling of controlling one’s own body. However, it is unclear how mirror therapy is related to the sense of agency over a phantom limb. Using mirror therapy, we investigated phantom limb pain and the senses of agency and ownership (i.e., a feeling of having one’s own body) of the phantom limb. Nine upper-limb amputees, five of whom reported recent phantom limb pain, underwent a single 15-min trial of mirror therapy. Before and after the trial, the participants completed a questionnaire regarding agency, ownership, and pain related to their phantom limb. They reported that the sense of agency over the phantom limb increased following the mirror therapy trial, while the ownership slightly increased but not as much as did the agency. The reported pain did not change; that is, it was comparably mild before and after the trial. These results suggest that short-term mirror therapy can, at least transiently, selectively enhance the sense of agency over a phantom limb, but may not alleviate phantom limb pain. PMID:29046630
Agency over Phantom Limb Enhanced by Short-Term Mirror Therapy.
Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi
2017-01-01
Most amputees experience phantom limb, whereby they feel that the amputated limb is still present. In some cases, these experiences include pain that can be alleviated by "mirror therapy." Mirror therapy consists of superimposing a mirrored image of the moving intact limb onto the phantom limb. This therapy provides a closed loop between the motor command to the amputated limb and its predicted visual feedback. This loop is also involved in the sense of agency, a feeling of controlling one's own body. However, it is unclear how mirror therapy is related to the sense of agency over a phantom limb. Using mirror therapy, we investigated phantom limb pain and the senses of agency and ownership (i.e., a feeling of having one's own body) of the phantom limb. Nine upper-limb amputees, five of whom reported recent phantom limb pain, underwent a single 15-min trial of mirror therapy. Before and after the trial, the participants completed a questionnaire regarding agency, ownership, and pain related to their phantom limb. They reported that the sense of agency over the phantom limb increased following the mirror therapy trial, while the ownership slightly increased but not as much as did the agency. The reported pain did not change; that is, it was comparably mild before and after the trial. These results suggest that short-term mirror therapy can, at least transiently, selectively enhance the sense of agency over a phantom limb, but may not alleviate phantom limb pain.
Lendrum, J.
1980-01-01
Alternatives to conventional skin flap cover for limb wounds extend both the number and type of defects which can now be closed with reconstruction of both form and function for patients who might otherwise come to amputation. The old adage that where a sinus leads to dead or foreign material it can only be closed after removal of that dead or foreign material is no longer true. The number of patients coming to above-knee amputation after prosthetic replacement of the knee joint could be reduced by muscle flap cover of exposed arthroplasty prostheses. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 PMID:7377695
Thermal Tides in the Martian Middle Atmosphere as Seen by the Mars Climate Sounder
Lee, C.; Lawson, W. G.; Richardson, M. I.; Heavens, N. G.; Kleinböhl, A.; Banfield, D.; McCleese, D. J.; Zurek, R.; Kass, D.; Schofield, J. T.; Leovy, C. B.; Taylor, F. W.; Toigo, A. D.
2016-01-01
The first systematic observations of the middle atmosphere of Mars (35km–80km) with the Mars Climate Sounder (MCS) show dramatic patterns of diurnal thermal variation, evident in retrievals of temperature and water ice opacity. At the time of writing, the dataset of MCS limb retrievals is sufficient for spectral analysis within a limited range of latitudes and seasons. This analysis shows that these thermal variations are almost exclusively associated with a diurnal thermal tide. Using a Martian General Circulation Model to extend our analysis we show that the diurnal thermal tide dominates these patterns for all latitudes and all seasons. PMID:27630378
NASA Astrophysics Data System (ADS)
Zabri, S. W. K. Ali; Basaruddin, K. S.; Salleh, A. F.; Rusli, W. M. R.; Daud, R.
2017-09-01
Leg length discrepancy (LLD) is caused either due to functional disorder or shortening of bone structure. This disorder could contribute to the significant effects on body weight distribution and lumbar scoliosis at the certain extend. Ground reaction force and joint reaction force are the parameters that can be used to analyze the responses in weight distribution and kinetics changes on the body joints, respectively. Hence, the purpose of this paper is to review the studies that focus on the clinical effects of LLD to the lower limb and spine through ground and joint reaction force responses that could lead to the orthopedics disorder.
The human power amplifier technology at the University of California, Berkeley.
Kazerooni, H
1996-01-01
A human's ability to perform physical tasks is limited by physical strength, not by intelligence. We define "extenders" as a class of robot manipulators worn by humans to augment human mechanical strength, while the wearer's intellect remains the central control system for manipulating the extender. Our research objective is to determine the ground rules for the design and control of robotic systems worn by humans through the design, construction, and control of several prototype experimental direct-drive/non-direct-drive multi-degree-of-freedom hydraulic/electric extenders. The design of extenders is different from the design of conventional robots because the extender interfaces with the human on a physical level. Two sets of force sensors measure the forces imposed on the extender by the human and by the environment (i.e., the load). The extender's compliances in response to such contact forces were designed by selecting appropriate force compensators. This paper gives a summary of some of the selected research efforts related to Extender Technology, carried out during 1980s. The references, at the end of this article, give detailed description of the research efforts.
Tsay, Anthony J; Giummarra, Melita J
2016-07-01
Awareness of limb position is derived primarily from muscle spindles and higher-order body representations. Although chronic pain appears to be associated with motor and proprioceptive disturbances, it is not clear if this is due to disturbances in position sense, muscle spindle function, or central representations of the body. This study examined position sense errors, as an indicator of spindle function, in participants with unilateral chronic limb pain. The sample included 15 individuals with upper limb pain, 15 with lower limb pain, and 15 sex- and age-matched pain-free control participants. A 2-limb forearm matching task in blindfolded participants, and a single-limb pointer task, with the reference limb hidden from view, was used to assess forearm position sense. Position sense was determined after muscle contraction or stretch, intended to induce a high or low spindle activity in the painful and nonpainful limbs, respectively. Unilateral upper and lower limb chronic pain groups produced position errors comparable with healthy control participants for position matching and pointer tasks. The results indicate that the painful and nonpainful limb are involved in limb-matching. Lateralized pain, whether in the arm or leg, does not influence forearm position sense. Painful and nonpainful limbs are involved in bilateral limb-matching. Muscle spindle function appears to be preserved in the presence of chronic pain. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Hyperinnervation improves Xenopus laevis limb regeneration.
Mitogawa, Kazumasa; Makanae, Aki; Satoh, Akira
2018-01-15
Xenopus laevis (an anuran amphibian) shows limb regeneration ability between that of urodele amphibians and that of amniotes. Xenopus frogs can initiate limb regeneration but fail to form patterned limbs. Regenerated limbs mainly consist of cone-shaped cartilage without any joints or branches. These pattern defects are thought to be caused by loss of proper expressions of patterning-related genes. This study shows that hyperinnervation surgery resulted in the induction of a branching regenerate. The hyperinnervated blastema allows the identification and functional analysis of the molecules controlling this patterning of limb regeneration. This paper focuses on the nerve affects to improve Xenopus limb patterning ability during regeneration. The nerve molecules, which regulate limb patterning, were also investigated. Blastemas grown in a hyperinnervated forelimb upregulate limb patterning-related genes (shh, lmx1b, and hoxa13). Nerves projecting their axons to limbs express some growth factors (bmp7, fgf2, fgf8, and shh). Inputs of these factors to a blastema upregulated some limb patterning-related genes and resulted in changes in the cartilage patterns in the regenerates. These results indicate that additional nerve factors enhance Xenopus limb patterning-related gene expressions and limb regeneration ability, and that bmp, fgf, and shh are candidate nerve substitute factors. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
[Development and technological transfer of functional pastas extended with legumes].
Granito, Marisela; Ascanio, Vanesa
2009-03-01
Development and technological transfer of functional pastas extended with legumes. Semolina pasta is a highly consumed foodstuff, the biological value of which is low because its protein is deficient in lysine. However, if the semolina is extended with legumes rich in this essential aminoacid, not only and aminoacid supplementation is produced, but also the dietary fibre and minerals are increased. In this work, pastas extended in 10% with a white variety of Phaseolus vulgaris and with Cajanus cajan were produced on a pilot plant scale, and this technology was transferred to a cooperative producing artisanal pastas. The cooking qualities and the physical, chemical, and nutritional characteristics of the pastas were evaluated, as well as the sensorial acceptability in institutionalized elderly people. The extension of the pastas with legume flours increased the optimum cooking time (15 to 20%), the weight (20% and 25%), and the loss of solids by cooking. Similarly, the functional value of the pastas increased by increasing the contents of minerals and dietary fibre. The protein content, as well as the protein digestibility in vitro also increased; however, the parameters of colour L, a and b, and the total starch content of the pastas decreased. At consumer level, the pastas extended with legumes had a good acceptability, for what it was concluded that the extension of the semolina with legume flours in the manufacture of pastas is technologically feasible.
Sonic hedgehog controls growth of external genitalia by regulating cell cycle kinetics
Seifert, Ashley W.; Zheng, Zhengui; Ormerod, Brandi K.; Cohn, Martin J.
2010-01-01
During embryonic development, cells are instructed which position to occupy, they interpret these cues as differentiation programmes, and expand these patterns by growth. Sonic hedgehog (Shh) specifies positional identity in many organs; however, its role in growth is not well understood. In this study, we show that inactivation of Shh in external genitalia extends the cell cycle from 8.5 to 14.4 h, and genital growth is reduced by ∼75%. Transient Shh signalling establishes pattern in the genital tubercle; however, transcriptional levels of G1 cell cycle regulators are reduced. Consequently, G1 length is extended, leading to fewer progenitor cells entering S-phase. Cell cycle genes responded similarly to Shh inactivation in genitalia and limbs, suggesting that Shh may regulate growth by similar mechanisms in different organ systems. The finding that Shh regulates cell number by controlling the length of specific cell cycle phases identifies a novel mechanism by which Shh elaborates pattern during appendage development. PMID:20975695
Hazlett, Brian A; McLay, Colin
2005-03-01
The big-handed brachyuran crab Heterozius rotundifrons extends the time spent in its anti-predator posture, limb extended posture, if exposed to chemical cues from crushed conspecifics. In this study, we tested whether crabs also respond to chemical cues from crushed heterospecific crabs, and if so, whether phylogenetic relations or ecological overlap is more important in influencing the duration of the anti-predator posture. Chemical cues from two other brachyuran crabs (Cyclograpsus lavauxi and Hemigrapsus sexdentatus), which do not overlap directly in ecological distribution with H. rotundifrons, elicited a duration of the anti-predator posture that was indistinguishable from that produced by conspecific chemical cues. In contrast, chemical cues from two anomuran crabs (Petrolisthes elongatus and Pagurus novizealandiae) that overlap in ecological distribution with H. rotundifrons, elicited durations of the antipredator posture that were significantly shorter than those of either conspecifics or more closely related crab species. Thus, phylogenetic relationship seems to be more important than ecological overlap in influencing anti-predator behavior in H. rotundifrons.
Aniołczyk, Halina; Mamrot, Paweł; Mariańska, Magda
2012-01-01
High-frequency (HF) welders are the most common devices that make use of dielectric heating. They are a source of high-intensity electromagnetic fields (EMFs). Manual operation of those welders makes that the limbs are exposed to EMFs of extremely high intensity, far in excess of the currently admissible values. The aim of this study was to update knowledge of actual exposure of HF welder operators to EMF and to optimize the procedure of exposure assessment. Measurements of the EMF intensity in the vicinity of 10 dielectric welders at work posts of 12 operators were performed. EMF measurements were made using the reference method, extended by auxiliary measurement points to measure induced currents I(L) in the limbs. Induced current measurements were performed in 20 operators tending the same HF welder. the highest values of the electric (E) and magnetic (H) fields measured at work posts were for whole body: E, up to 350 V/m, and H, up to 1.00 A/m; and for limbs: E, up to 600 V/m and H, up to 3.30 A/m. The W exposure indicator in the primary vertical measurement points was almost as high as 60. I(L) values measured at the wrist exceeded 64 mA and were individual-operator-dependent. EMF exposure of 25% of HF welder operators exceeded the national admissible values and after taking into account the operators' hands, this figure rose to 50%. The measured value of I(L), representing a measure of internal exposure to EMF, should serve as the main criterion in deciding whether working conditions are admissible.
Aerosol Correction for Improving OMPS/LP Ozone Retrieval
NASA Technical Reports Server (NTRS)
Chen, Zhong; Bhartia, Pawan K.; Loughman, Robert
2015-01-01
The Ozone Mapping and Profiler Suite Limb Profiler (OMPS-LP) on board the Suomi National Polar-orbiting Partnership (SNPP) satellite was launched on Oct. 28, 2011. Limb profilers measures the radiance scattered from the Earth's atmospheric in limb viewing mode from 290 to 1000 nm and infer ozone profiles from tropopause to 60 km. The recently released OMPS-LP Version 2 data product contains the first publicly released ozone profiles retrievals, and these are now available for the entire OMPS mission, which extends from April, 2012. The Version 2 data product retrievals incorporate several important improvements to the algorithm. One of the primary changes is to turn off the aerosol retrieval module. The aerosol profiles retrieved inside the ozone code was not helping the ozone retrieval and was adding noise and other artifacts. Aerosols including polar stratospheric cloud (PSC) and polar mesospheric clouds (PMC) have a detectable effect on OMPS-LP data. Our results show that ignoring the aerosol contribution would produce an ozone density bias of up to 10 percent in the region of maximum aerosol extinction. Therefore, aerosol correction is needed to improve the quality of the retrieved ozone concentration profile. We provide Aerosol Scattering Index (ASI) for detecting aerosols-PMC-PSC, defined as ln(Im-Ic) normalized at 45km, where Im is the measured radiance and Ic is the calculated radiance assuming no aerosols. Since ASI varies with wavelengths, latitude and altitude, we can start by assuming no aerosol profiles in calculating the ASIs and then use the aerosol profile to see if it significantly reduces the residuals. We also discuss the effect of aerosol size distribution on the ozone profile retrieval process. Finally, we present an aerosol-PMC-PSC correction scheme.
Muscle mechanical advantage of human walking and running: implications for energy cost.
Biewener, Andrew A; Farley, Claire T; Roberts, Thomas J; Temaner, Marco
2004-12-01
Muscular forces generated during locomotion depend on an animal's speed, gait, and size and underlie the energy demand to power locomotion. Changes in limb posture affect muscle forces by altering the mechanical advantage of the ground reaction force (R) and therefore the effective mechanical advantage (EMA = r/R, where r is the muscle mechanical advantage) for muscle force production. We used inverse dynamics based on force plate and kinematic recordings of humans as they walked and ran at steady speeds to examine how changes in muscle EMA affect muscle force-generating requirements at these gaits. We found a 68% decrease in knee extensor EMA when humans changed gait from a walk to a run compared with an 18% increase in hip extensor EMA and a 23% increase in ankle extensor EMA. Whereas the knee joint was extended (154-176 degrees) during much of the support phase of walking, its flexed position (134-164 degrees) during running resulted in a 5.2-fold increase in quadriceps impulse (time-integrated force during stance) needed to support body weight on the ground. This increase was associated with a 4.9-fold increase in the ground reaction force moment about the knee. In contrast, extensor impulse decreased 37% (P < 0.05) at the hip and did not change at the ankle when subjects switched from a walk to a run. We conclude that the decrease in limb mechanical advantage (mean limb extensor EMA) and increase in knee extensor impulse during running likely contribute to the higher metabolic cost of transport in running than in walking. The low mechanical advantage in running humans may also explain previous observations of a greater metabolic cost of transport for running humans compared with trotting and galloping quadrupeds of similar size.
Lower extremity finite element model for crash simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schauer, D.A.; Perfect, S.A.
1996-03-01
A lower extremity model has been developed to study occupant injury mechanisms of the major bones and ligamentous soft tissues resulting from vehicle collisions. The model is based on anatomically correct digitized bone surfaces of the pelvis, femur, patella and the tibia. Many muscles, tendons and ligaments were incrementally added to the basic bone model. We have simulated two types of occupant loading that occur in a crash environment using a non-linear large deformation finite element code. The modeling approach assumed that the leg was passive during its response to the excitation, that is, no active muscular contraction and thereforemore » no active change in limb stiffness. The approach recognized that the most important contributions of the muscles to the lower extremity response are their ability to define and modify the impedance of the limb. When nonlinear material behavior in a component of the leg model was deemed important to response, a nonlinear constitutive model was incorporated. The accuracy of these assumptions can be verified only through a review of analysis results and careful comparison with test data. As currently defined, the model meets the objective for which it was created. Much work remains to be done, both from modeling and analysis perspectives, before the model can be considered complete. The model implements a modeling philosophy that can accurately capture both kinematic and kinetic response of the lower limb. We have demonstrated that the lower extremity model is a valuable tool for understanding the injury processes and mechanisms. We are now in a position to extend the computer simulation to investigate the clinical fracture patterns observed in actual crashes. Additional experience with this model will enable us to make a statement on what measures are needed to significantly reduce lower extremity injuries in vehicle crashes. 6 refs.« less
EMG-Torque correction on Human Upper extremity using Evolutionary Computation
NASA Astrophysics Data System (ADS)
JL, Veronica; Parasuraman, S.; Khan, M. K. A. Ahamed; Jeba DSingh, Kingsly
2016-09-01
There have been many studies indicating that control system of rehabilitative robot plays an important role in determining the outcome of the therapy process. Existing works have done the prediction of feedback signal in the controller based on the kinematics parameters and EMG readings of upper limb's skeletal system. Kinematics and kinetics based control signal system is developed by reading the output of the sensors such as position sensor, orientation sensor and F/T (Force/Torque) sensor and there readings are to be compared with the preceding measurement to decide on the amount of assistive force. There are also other works that incorporated the kinematics parameters to calculate the kinetics parameters via formulation and pre-defined assumptions. Nevertheless, these types of control signals analyze the movement of the upper limb only based on the movement of the upper joints. They do not anticipate the possibility of muscle plasticity. The focus of the paper is to make use of the kinematics parameters and EMG readings of skeletal system to predict the individual torque of upper extremity's joints. The surface EMG signals are fed into different mathematical models so that these data can be trained through Genetic Algorithm (GA) to find the best correlation between EMG signals and torques acting on the upper limb's joints. The estimated torque attained from the mathematical models is called simulated output. The simulated output will then be compared with the actual individual joint which is calculated based on the real time kinematics parameters of the upper movement of the skeleton when the muscle cells are activated. The findings from this contribution are extended into the development of the active control signal based controller for rehabilitation robot.
Marín, Liliana M; Iazbik, M Cristina; Zaldivar-Lopez, Sara; Lord, Linda K; Stingle, Nicole; Vilar, Paulo; Lara-Garcia, Ana; Alvarez, Francisco; Hosoya, Kenji; Nelson, Laura; Pozzi, Antonio; Cooper, Edward; McLoughlin, Mary A; Ball, Rebecca; Kisseberth, William C; London, Cheryl A; Dudley, Robert; Dyce, Jonathan; McMahon, Melanie; Lerche, Phillip; Bednarski, Richard; Couto, C Guillermo
2012-06-01
To determine the frequency of delayed postoperative bleeding in retired racing Greyhounds with appendicular bone tumors undergoing limb amputations. To identify if administration of epsilon-aminocaproic acid (EACA) was effective on the prevention of postoperative bleeding. Retrospective study from December 2003 to December 2008. Veterinary university teaching hospital. Forty-six retired racing Greyhounds (RRGs) diagnosed with primary appendicular bone tumors that underwent limb amputation were included in the study. None. Thirteen of 46 RRGs (28%) included in the study had delayed postoperative bleeding starting 48-72 h after surgery. Bleeding episodes included cutaneous, subcutaneous, and external bleeding that extended from the area of the surgical site that became widespread within hours, and that required administration of blood components. A paired t-test suggests that there was a significant decrease in PCV postoperatively for both dogs that bled and dogs that did not bleed (P < 0.0001). Forty of 46 RRGs (86%) received either fresh frozen plasma (FFP) or EACA or both, for the prevention of postoperative bleeding. A logistic regression model determined that dogs that did not receive EACA were 5.7 times more likely to bleed than dogs that did receive EACA, when controlling for whether or not they received FFP (95% CI: 1.02-32.15, P = 0.047). This retrospective study suggests that preemptive postoperative administration of EACA appears to be efficacious in decreasing the frequency of bleeding in RRGs undergoing limb amputation; however, a prospective study is warranted to corroborate its effectiveness. © Veterinary Emergency and Critical Care Society 2012.
NASA Astrophysics Data System (ADS)
Hahn, Markus; Barrois, Björn; Krüger, Lars; Wöhler, Christian; Sagerer, Gerhard; Kummert, Franz
2010-09-01
This study introduces an approach to model-based 3D pose estimation and instantaneous motion analysis of the human hand-forearm limb in the application context of safe human-robot interaction. 3D pose estimation is performed using two approaches: The Multiocular Contracting Curve Density (MOCCD) algorithm is a top-down technique based on pixel statistics around a contour model projected into the images from several cameras. The Iterative Closest Point (ICP) algorithm is a bottom-up approach which uses a motion-attributed 3D point cloud to estimate the object pose. Due to their orthogonal properties, a fusion of these algorithms is shown to be favorable. The fusion is performed by a weighted combination of the extracted pose parameters in an iterative manner. The analysis of object motion is based on the pose estimation result and the motion-attributed 3D points belonging to the hand-forearm limb using an extended constraint-line approach which does not rely on any temporal filtering. A further refinement is obtained using the Shape Flow algorithm, a temporal extension of the MOCCD approach, which estimates the temporal pose derivative based on the current and the two preceding images, corresponding to temporal filtering with a short response time of two or at most three frames. Combining the results of the two motion estimation stages provides information about the instantaneous motion properties of the object. Experimental investigations are performed on real-world image sequences displaying several test persons performing different working actions typically occurring in an industrial production scenario. In all example scenes, the background is cluttered, and the test persons wear various kinds of clothes. For evaluation, independently obtained ground truth data are used. [Figure not available: see fulltext.
Wang, Jiajing; Hmadcha, Abdelkrim; Zakarian, Vaagn; Song, Fei; Loeb, Jeffrey A
2015-09-01
The neuregulins (NRGs) are a family of alternatively spliced factors that play important roles in nervous system development and disease. In motor neurons, NRG1 expression is regulated by activity and neurotrophic factors, however, little is known about what controls isoform-specific transcription. Here we show that NRG1 expression in the chick embryo increases in motor neurons that have extended their axons and that limb bud ablation before motor axon outgrowth prevents this induction, suggesting a trophic role from the developing limb. Consistently, NRG1 induction after limb bud ablation can be rescued by adding back the neurotrophic factors BDNF and GDNF. Mechanistically, BDNF induces a rapid and transient increase in type I and type III NRG1 mRNAs that peak at 4h in rat embryonic ventral spinal cord cultures. Blocking MAPK or PI3K signaling or blocking transcription with Actinomycin D blocks BDNF induced NRG1 gene induction. BDNF had no effect on mRNA degradation, suggesting that transcriptional activation rather than message stability is important. Furthermore, BDNF activates a reporter construct that includes 700bp upstream of the type I NRG1 start site. Protein synthesis is also required for type I NRG1 mRNA transcription as cycloheximide produced a super-induction of type I, but not type III NRG1 mRNA, possibly through a mechanism involving sustained activation of MAPK and PI3K. These results reveal the existence of highly responsive, transient transcriptional regulatory mechanisms that differentially modulate NRG1 isoform expression as a function of extracellular and intracellular signaling cascades and mediated by neurotrophic factors and axon-target interactions. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Feofilov, A. G.; Kutepov, A. A.; Rezac, L.; Smith, M. D.
2015-01-01
This paper describes a methodology for performing a temperature retrieval in the Martian atmosphere in the 50-90 km altitude range using spectrally integrated 15 micrometers C02 limb emissions measured by the Thermal Emission Spectrometer (TES), the thermal infrared spectrometer on board the Mars Global Surveyor (MGS). We demonstrate that temperature retrievals from limb observations in the 75-90 km altitude range require accounting for the non-local thermodynamic equilibrium (non-LTE) populations of the C02(v2) vibrational levels. Using the methodology described in the paper, we have retrieved approximately 1200 individual temperature profiles from MGS TES limb observations in the altitude range between 60 and 90 km. 0ur dataset of retrieved temperature profiles is available for download in supplemental materials of this paper. The temperature retrieval uncertainties are mainly caused by radiance noise, and are estimated to be about 2 K at 60 km and below, 4 K at 70 km, 7 K at 80 km, 10 K at 85 km, and 20 K at 90 km. We compare the retrieved profiles to Mars Climate Database temperature profiles and find good qualitative agreement. Quantitatively, our retrieved profiles are in general warmer and demonstrate strong variability with the following values for bias and standard deviations (in brackets) compared to the Martian Year 24 dataset of the Mars Climate Database: 6 (+/-20) K at 60 km, 7.5 (+/-25) K at 65 km, 9 (+/-27) K at 70 km, 9.5 (+/-27) K at 75 km, 10 (+/-28) K at 80 km, 11 (+/-29) K at 85 km, and 11.5 (+/-31) K at 90 km. Possible reasons for the positive temperature bias are discussed. carbon dioxide molecular vibrations
Fine-tuning the onset of myogenesis by homeobox proteins that interact with the Myf5 limb enhancer
Daubas, Philippe; Duval, Nathalie; Bajard, Lola; Langa Vives, Francina; Robert, Benoît; Mankoo, Baljinder S.; Buckingham, Margaret
2015-01-01
ABSTRACT Skeletal myogenesis in vertebrates is initiated at different sites of skeletal muscle formation during development, by activation of specific control elements of the myogenic regulatory genes. In the mouse embryo, Myf5 is the first myogenic determination gene to be expressed and its spatiotemporal regulation requires multiple enhancer sequences, extending over 120 kb upstream of the Mrf4-Myf5 locus. An enhancer, located at −57/−58 kb from Myf5, is responsible for its activation in myogenic cells derived from the hypaxial domain of the somite, that will form limb muscles. Pax3 and Six1/4 transcription factors are essential activators of this enhancer, acting on a 145-bp core element. Myogenic progenitor cells that will form the future muscle masses of the limbs express the factors necessary for Myf5 activation when they delaminate from the hypaxial dermomyotome and migrate into the forelimb bud, however they do not activate Myf5 and the myogenic programme until they have populated the prospective muscle masses. We show that Msx1 and Meox2 homeodomain-containing transcription factors bind in vitro and in vivo to specific sites in the 145-bp element, and are implicated in fine-tuning activation of Myf5 in the forelimb. Msx1, when bound between Pax and Six sites, prevents the binding of these key activators, thus inhibiting transcription of Myf5 and consequent premature myogenic differentiation. Meox2 is required for Myf5 activation at the onset of myogenesis via direct binding to other homeodomain sites in this sequence. Thus, these homeodomain factors, acting in addition to Pax3 and Six1/4, fine-tune the entry of progenitor cells into myogenesis at early stages of forelimb development. PMID:26538636
Mostafa, Ayman A; Cunningham, Devin P; Boudrieau, Randy J; Kowaleski, Michael P; Griffon, Dominique J
2018-04-01
To determine repeatability of and correlation between 2 radiographic measurements of femoral anteversion angles (FAA) and to determine their influence on a score derived from tibial plateau angle (TPA) and FAA to predict the risk of cranial cruciate ligament disease (CCLD). Prospective clinical study. Forty-eight Labrador retrievers with or without CCLD. FAA and CCLD scores were calculated for each limb from extended pelvic radiographs (t-FAA) or angled (a-FAA) projections of the femur by 3 investigators. One investigator repeated measurements twice. Data were analyzed for repeatability, correlation between t-FAA and a-FAA, and their influence on CCLD scores. FAA correlated most strongly with the distance between the femoral head and the femoral axis on mediolateral radiographs, a measurement with excellent repeatability. t-FAA and a-FAA correlated with each other (r > 0.79, P < .0001), although t-FAA were about 1° greater than a-FAA (P = .01). Intrainvestigator and interinvestigator repeatability of the CCLD score was fair when derived from t-FAA and good to excellent when derived from a-FAA. CCLD scores differed between radiographic techniques but led to different predictions in only 9 (10%) limbs, all with lower TPA and CCLD scores than the rest of the population. a-FAA correlated strongly with t-FAA and improved the repeatability of CCLD scores within and between investigators. A craniocaudal angled beam projection of the femur is a suitable alternative to a ventrodorsal pelvic radiograph when measuring FAA and may improve the repeatability and positive predictive value of CCLD scores. © 2018 The American College of Veterinary Surgeons.