Impact of Extended Daylight Saving Time on National Energy Consumption Report to Congress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belzer, D. B.; Hadley, S. W.; Chin, S-M.
2008-10-01
The Energy Policy Act of 2005 (Pub. L. No. 109-58; EPAct 2005) amended the Uniform Time Act of 1966 (Pub. L. No. 89-387) to increase the portion of the year that is subject to Daylight Saving Time. (15 U.S.C. 260a note) EPAct 2005 extended the duration of Daylight Saving Time in the spring by changing its start date from the first Sunday in April to the second Sunday in March, and in the fall by changing its end date from the last Sunday in October to the first Sunday in November. (15 U.S.C. 260a note) EPAct 2005 also called formore » the Department of Energy to evaluate the impact of Extended Daylight Saving Time on energy consumption in the United States and to submit a report to Congress. (15 U.S.C. 260a note) This report presents the results of impacts of Extended Daylight Saving Time on the national energy consumption in the United States. The key findings are: (1) The total electricity savings of Extended Daylight Saving Time were about 1.3 Tera Watt-hour (TWh). This corresponds to 0.5 percent per each day of Extended Daylight Saving Time, or 0.03 percent of electricity consumption over the year. In reference, the total 2007 electricity consumption in the United States was 3,900 TWh. (2) In terms of national primary energy consumption, the electricity savings translate to a reduction of 17 Trillion Btu (TBtu) over the spring and fall Extended Daylight Saving Time periods, or roughly 0.02 percent of total U.S. energy consumption during 2007 of 101,000 TBtu. (3) During Extended Daylight Saving Time, electricity savings generally occurred over a three- to five-hour period in the evening with small increases in usage during the early-morning hours. On a daily percentage basis, electricity savings were slightly greater during the March (spring) extension of Extended Daylight Saving Time than the November (fall) extension. On a regional basis, some southern portions of the United States exhibited slightly smaller impacts of Extended Daylight Saving Time on energy savings compared to the northern regions, a result possibly due to a small, offsetting increase in household air conditioning usage. (4) Changes in national traffic volume and motor gasoline consumption for passenger vehicles in 2007 were determined to be statistically insignificant and therefore, could not be attributed to Extended Daylight Saving Time.« less
47 CFR 73.99 - Presunrise service authorization (PSRA) and postsunset service authorization (PSSA).
Code of Federal Regulations, 2013 CFR
2013-10-01
... authorization. (c) Extended Daylight Saving Time Pre-Sunrise Authorizations: (1) Between the first Sunday in... presunrise operations during extended daylight saving time and shall issue conforming authorizations. These...
47 CFR 73.99 - Presunrise service authorization (PSRA) and postsunset service authorization (PSSA).
Code of Federal Regulations, 2011 CFR
2011-10-01
... authorization. (c) Extended Daylight Saving Time Pre-Sunrise Authorizations: (1) Between the first Sunday in... presunrise operations during extended daylight saving time and shall issue conforming authorizations. These...
NASA Astrophysics Data System (ADS)
Murray, Patrick L.
Government programs designed to decrease resource consumption, improve productivity and capitalize on extended daylight hours in the summer have been developed and implemented throughout the world for nearly three hundred years. In 2005, The United States government adopted an extended daylight savings program that increases the number of weeks where the country observes Daylight Saving Time (DST) from 31 to 35 weeks. The program took effect in March 2007. Arguments in support of DST programs highlight the portion of electricity consumption attributed to residential lighting in the evening hours. Adjusting clocks forward by one hour in summer months is believed to reduce electricity consumption due to lighting and therefore significantly reduce residential energy consumption during the period of DST. This paper evaluates the efficacy of the changes to DST resulting from the Energy Policy Act of 2005. The study focuses on changes to household electricity consumption during the extended four weeks of DST. Arizona, one of two states that continue to opt out of DST serves as the study's control for a comparison with neighboring states, Colorado, Nebraska, Nevada, New Mexico, Oklahoma, Texas and Utah. Results from the regression analysis of a Difference in Difference model indicate that contrary to evaluations by Congress and the Department of Energy, the four week period of Extended Daylight Saving Time does not produce a significant decrease in per capita electricity consumption in Southwestern states.
Rosenberg, Michael; Wood, Lisa
2010-02-01
To measure the impact of the introduction of daylight saving in Western Australia in December 2006 on when during the day adults engaged in physical activity. In early December 2006, 1,300 Western Australian adults were telephoned and asked about how the introduction of daylight saving would influence when during the day they typically engaged in physical activity. At the end of the daylight saving period in March 2007, 1,083 of the baseline cohort agreed to answer questions relating to how daylight saving had affected when during the day they were physically active. Almost half the cohort (45.5%) reported that daylight saving had affected when during the day they were physically active. During daylight saving fewer people exercised in the morning and more people exercised in the evening. When analysed at the individual level, 23% of the cohort ceased to exercise in the morning during daylight saving and 22% exercised in the evening only during daylight saving. In addition, to changes in when during the day people exercised, there was also an overall reduction in the average number of daily exercise sessions, with 8% not exercising at all during daylight saving. The results suggest that the introduction of daylight saving, a relatively modest compulsory change to increase daylight by one hour had an impact on patterns of when during the day people were physically active. The study results reinforce the value of focusing on policy as an effective means of supporting population behaviour change. © 2010 The Authors. Journal Compilation © 2010 Public Health Association of Australia.
DOT National Transportation Integrated Search
1975-06-01
The analyses of the effects of Year-Round Daylight Saving Time were not conslusive because they could not be reliablyseparated from other changes occuring simultaneously including fuel availability constraints, speed limit reductions, Sunday gasoline...
Project Lateday : The Level of Accidents Under the Effect of Daylight Saving All Year
DOT National Transportation Integrated Search
1975-10-01
Year-round daylight saving time (YRDST) has recently been observed in the United States. The observance of double daylight saving time (DDST) is under some consideration. One of the principal expected effects of the adoption of these time systems is ...
Effects of daylight savings time changes on stock market volatility.
Berument, M Hakan; Dogan, Nukhet; Onar, Bahar
2010-04-01
The presence of daylight savings time effects on stock returns and on stock volatility was investigated using an EGARCH specification to model the conditional variance. The evidence gathered from the major United States stock markets for the period between 1967 and 2007 did not support the existence of the daylight savings time effect on stock returns or on volatility. Returns on the first business day following daylight savings time changes were not lower nor was the volatility higher, as would be expected if there were an effect.
17 CFR 232.13 - Date of filing; adjustment of filing date.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed filed on.... Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed... Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4...
17 CFR 232.13 - Date of filing; adjustment of filing date.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed filed on.... Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed... Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4...
17 CFR 232.13 - Date of filing; adjustment of filing date.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed filed on.... Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed... Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4...
17 CFR 232.13 - Date of filing; adjustment of filing date.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed filed on.... Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed... Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4...
Does Daylight Savings Time encourage physical activity?
Zick, Cathleen D
2014-07-01
Extending Daylight Savings Time (DST) has been identified as a policy intervention that may encourage physical activity. However, there has been little research on the question of if DST encourages adults to be more physically active. Data from residents of Arizona, Colorado, New Mexico, and Utah ages 18-64 who participated in the 2003-2009 American Time Use Survey are used to assess whether DST is associated with increased time spent in moderate-to-vigorous physical activity (MVPA). The analysis capitalizes on the natural experiment created because Arizona does not observe DST. Both bivariate and multivariate analyses indicate that shifting 1 hour of daylight from morning to evening does not impact MVPA of Americans living in the southwest. While DST may affect the choices people make about the timing and location of their sports/recreational activities, the potential for DST to serve as a broad-based intervention that encourages greater sports/recreation participation is not supported by this analysis. Whether this null effect would persist in other climate situations is an open question.
Hicks, G J; Davis, J W; Hicks, R A
1998-06-01
On the hypothesis that sleepiness and alcohol interact to increase the risk of alcohol-related traffic fatalities, the percentages of alcohol-related fatal traffic crashes were assessed for the entire state of New Mexico for the years 1989-1992, for each of the seven days that preceded the changes to and from Daylight Savings Time and for each of the 14 days which followed the changes to and from Daylight Savings Time. Consistent with our hypothesis the percentage of alcohol-related fatal crashes increased significantly during the first seven days after these changes in Daylight Savings Time.
Daylight saving time transitions and hospital treatments due to accidents or manic episodes
Lahti, Tuuli A; Haukka, Jari; Lönnqvist, Jouko; Partonen, Timo
2008-01-01
Background Daylight saving time affects millions of people annually but its impacts are still widely unknown. Sleep deprivation and the change of circadian rhythm can trigger mental illness and cause higher accident rates. Transitions into and out of daylight saving time changes the circadian rhythm and may cause sleep deprivation. Thus it seems plausible that the prevalence of accidents and/or manic episodes may be higher after transition into and out of daylight saving time. The aim of this study was to explore the effects of transitions into and out of daylight saving time on the incidence of accidents and manic episodes in the Finnish population during the years of 1987 to 2003. Methods The nationwide data were derived from the Finnish Hospital Discharge Register. From the register we obtained the information about the hospital-treated accidents and manic episodes during two weeks before and two weeks after the transitions in 1987–2003. Results The results were negative, as the transitions into or out of daylight saving time had no significant effect on the incidence of accidents or manic episodes. Conclusion One-hour transitions do not increase the incidence of manic episodes or accidents which require hospital treatment. PMID:18302734
Predicting energy savings attributed to daylighting
NASA Astrophysics Data System (ADS)
Robbins, C. L.
1982-08-01
A method is described for estimating a building's energy savings attributed to daylighting by predicting the percentage of the year that the electric lighting system is not in use. This depends on the particular control strategy chosen, a standard work year, and the amount of light (as a daylight factor) reaching on daylight and sunlight availability for selected cities in the United States.
Daylight Saving Time Transitions and Road Traffic Accidents
Lahti, Tuuli; Nysten, Esa; Haukka, Jari; Sulander, Pekka; Partonen, Timo
2010-01-01
Circadian rhythm disruptions may have harmful impacts on health. Circadian rhythm disruptions caused by jet lag compromise the quality and amount of sleep and may lead to a variety of symptoms such as fatigue, headache, and loss of attention and alertness. Even a minor change in time schedule may cause considerable stress for the body. Transitions into and out of daylight saving time alter the social and environmental timing twice a year. According to earlier studies, this change in time-schedule leads to sleep disruption and fragmentation of the circadian rhythm. Since sleep deprivation decreases motivation, attention, and alertness, transitions into and out of daylight saving time may increase the amount of accidents during the following days after the transition. We studied the amount of road traffic accidents one week before and one week after transitions into and out of daylight saving time during years from 1981 to 2006. Our results demonstrated that transitions into and out of daylight saving time did not increase the number of traffic road accidents. PMID:20652036
17 CFR 240.0-2 - Business hours of the Commission.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Eastern Daylight Saving Time, whichever currently is in effect in Washington, DC, provided that hours for... 8 a.m. to 10 p.m., Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in... Saturdays, Sundays and federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight...
17 CFR 240.0-2 - Business hours of the Commission.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Eastern Daylight Saving Time, whichever currently is in effect in Washington, DC, provided that hours for... 8 a.m. to 10 p.m., Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in... Saturdays, Sundays and federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight...
Predicting energy savings attributed to daylighting
NASA Astrophysics Data System (ADS)
Robbins, C. L.
1983-11-01
A method for estimating a building's energy savings attributable to daylighting by predicting the percentage of the year that the electric lighting system is not in use is described. This method depends upon the particular control stragegy chosen, a standard work year, and the amount of light (as a daylight factor, DF) reaching any given station in the building.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-27
... Eastern Daylight Saving Time on June 20, 2011. ADDRESSES: Comments must be identified with ``RIN 1219-AB64... commenters additional time to review and comment on the proposed rule. DATES: The comment period for the... providing additional time for interested parties to submit comments. MSHA is extending the comment period...
Year-Round Daylight Saving Time Study : Volume 2. Supporting Studies
DOT National Transportation Integrated Search
1975-06-01
This volume contains detailed background material in support of findings of the Interim Report. It includes the findings of a survey of attifudes towards daylight saving conducted by the National Opinion Research Center; description of sunrise and su...
A Study on the Optimal Duration of Daylight Saving Time (DST) in Korea
NASA Astrophysics Data System (ADS)
Mihn, Byeong-Hee; Ahn, Young Sook; Kim, Dong-Bin; Yang, Hong-Jin
2009-09-01
Daylight saving time aims at spending effective daylight in summer season. Korea had enforced daylight saving time twelve times from 1948 to 1988. Since 1988, it is not executed, but it is recently discussed the resumption of DST. In this paper, we investigate the trend of DST in other countries, review the history of DST in Korea, and suggest the optimal DST duration in terms of astronomical aspects (times of sunrise and sunset). We find that the starting day of DST in Korea is apt for the second Sunday in May or the second Sunday in April according to the time of sunrise or to the difference between Korean standard meridian and observer's, respectively. We also discuss time friction that might be caused by time difference between DST and Korea Standard Time (KST).
Spectral Analysis of the Effects of Daylight Saving Time on Motor Vehicle Fatal Traffic Accidents
DOT National Transportation Integrated Search
1977-04-01
This report shows that Daylight Saving Time (DST) reduces the number of persons killed in motor vehicle fatal traffic accidents by about one percent. This estimate is based on a spectral (Fourier) analysis of these fatalities which utilizes a filteri...
Change in the Classroom Deportment of Children Following Change From Daylight Saving Time.
ERIC Educational Resources Information Center
Hicks, Robert A.; And Others
1980-01-01
The deportment of each student in a third-grade classroom was rated by the teacher before and after the fall change from daylight savings time, to see if this disruption in circadian rhythms alters behavior. The deportment of boys improved significantly while the deportment of girls was significantly disrupted. (Author/SJL)
Daylight Savings Time Transitions and the Incidence Rate of Unipolar Depressive Episodes.
Hansen, Bertel T; Sønderskov, Kim M; Hageman, Ida; Dinesen, Peter T; Østergaard, Søren D
2017-05-01
Daylight savings time transitions affect approximately 1.6 billion people worldwide. Prior studies have documented associations between daylight savings time transitions and adverse health outcomes, but it remains unknown whether they also cause an increase in the incidence rate of depressive episodes. This seems likely because daylight savings time transitions affect circadian rhythms, which are implicated in the etiology of depressive disorder. Therefore, we investigated the effects of daylight savings time transitions on the incidence rate of unipolar depressive episodes. Using time series intervention analysis of nationwide data from the Danish Psychiatric Central Research Register from 1995 to 2012, we compared the observed trend in the incidence rate of hospital contacts for unipolar depressive episodes after the transitions to and from summer time to the predicted trend in the incidence rate. The analyses were based on 185,419 hospital contacts for unipolar depression and showed that the transition from summer time to standard time were associated with an 11% increase (95% CI = 7%, 15%) in the incidence rate of unipolar depressive episodes that dissipated over approximately 10 weeks. The transition from standard time to summer time was not associated with a parallel change in the incidence rate of unipolar depressive episodes. This study shows that the transition from summer time to standard time was associated with an increase in the incidence rate of unipolar depressive episodes. Distress associated with the sudden advancement of sunset, marking the coming of a long period of short days, may explain this finding. See video abstract at, http://links.lww.com/EDE/B179.
Daylighting Strategies Promote Healthy High Performance Buildings
ERIC Educational Resources Information Center
Gille, Steve
2010-01-01
There are many reasons to incorporate daylighting into the building or renovation of K-16 learning facilities. Benefits include increased productivity for students and staff, improved health, a better connection to the outdoors, energy savings and better quality of light. Add the role daylighting can play in LEED certification and it's clear that…
None
2018-02-14
Daylightingâthe use of windows or skylights for natural lighting and temperature regulationâis one building strategy that can save money for homeowners and businesses. Highly efficient, strategically placed windows maximize the use of natural daylight in a building, lowering the need for artificial lighting without causing heating or cooling problems.
Testing simulation and structural models with applications to energy demand
NASA Astrophysics Data System (ADS)
Wolff, Hendrik
2007-12-01
This dissertation deals with energy demand and consists of two parts. Part one proposes a unified econometric framework for modeling energy demand and examples illustrate the benefits of the technique by estimating the elasticity of substitution between energy and capital. Part two assesses the energy conservation policy of Daylight Saving Time and empirically tests the performance of electricity simulation. In particular, the chapter "Imposing Monotonicity and Curvature on Flexible Functional Forms" proposes an estimator for inference using structural models derived from economic theory. This is motivated by the fact that in many areas of economic analysis theory restricts the shape as well as other characteristics of functions used to represent economic constructs. Specific contributions are (a) to increase the computational speed and tractability of imposing regularity conditions, (b) to provide regularity preserving point estimates, (c) to avoid biases existent in previous applications, and (d) to illustrate the benefits of our approach via numerical simulation results. The chapter "Can We Close the Gap between the Empirical Model and Economic Theory" discusses the more fundamental question of whether the imposition of a particular theory to a dataset is justified. I propose a hypothesis test to examine whether the estimated empirical model is consistent with the assumed economic theory. Although the proposed methodology could be applied to a wide set of economic models, this is particularly relevant for estimating policy parameters that affect energy markets. This is demonstrated by estimating the Slutsky matrix and the elasticity of substitution between energy and capital, which are crucial parameters used in computable general equilibrium models analyzing energy demand and the impacts of environmental regulations. Using the Berndt and Wood dataset, I find that capital and energy are complements and that the data are significantly consistent with duality theory. Both results would not necessarily be achieved using standard econometric methods. The final chapter "Daylight Time and Energy" uses a quasi-experiment to evaluate a popular energy conservation policy: we challenge the conventional wisdom that extending Daylight Saving Time (DST) reduces energy demand. Using detailed panel data on half-hourly electricity consumption, prices, and weather conditions from four Australian states we employ a novel 'triple-difference' technique to test the electricity-saving hypothesis. We show that the extension failed to reduce electricity demand and instead increased electricity prices. We also apply the most sophisticated electricity simulation model available in the literature to the Australian data. We find that prior simulation models significantly overstate electricity savings. Our results suggest that extending DST will fail as an instrument to save energy resources.
Teaching Science: Beats the Daylight Out of Me.
ERIC Educational Resources Information Center
Leyden, Michael B.
1995-01-01
Presents activities for observing, measuring, collecting, and graphing data about times of sunrise and sunset to teach an understanding about arrival of Daylight Savings Time in April. Also discusses seasonal affective disorder (SAD). (TM)
Optimal integration of daylighting and electric lighting systems using non-imaging optics
NASA Astrophysics Data System (ADS)
Scartezzini, J.-L.; Linhart, F.; Kaegi-Kolisnychenko, E.
2007-09-01
Electric lighting is responsible for a significant fraction of electricity consumption within non-residential buildings. Making daylight more available in office and commercial buildings can lead as a consequence to important electricity savings, as well as to the improvement of occupants' visual performance and wellbeing. Over the last decades, daylighting technologies have been developed for that purpose, some of them having proven to be highly efficient such as anidolic daylighting systems. Based on non-imaging optics these optical devices were designed to achieve an efficient collection and redistribution of daylight within deep office rooms. However in order to benefit from the substantial daylight provision obtained through these systems and convert it into effective electricity savings, novel electric lighting strategies are required. An optimal integration of high efficacy light sources and efficient luminaries based on non-imaging optics with anidolic daylighting systems can lead to such novel strategies. Starting from the experience gained through the development of an Anidolic Integrated Ceiling (AIC), this paper presents an optimal integrated daylighting and electric lighting system. Computer simulations based on ray-tracing techniques were used to achieve the integration of 36W fluorescent tubes and non-imaging reflectors with an advanced daylighting system. Lighting power densities lower than 4 W/m2 can be achieved in this way within the corresponding office room. On-site monitoring of an integrated daylighting and electric lighting system carried out on a solar experimental building confirmed the energy and visual performance of such a system: it showed that low lighting power densities can be achieved by combining an anidolic daylighting system with very efficient electric light sources and luminaries.
Designed To Maximize Learning and Minimize Costs.
ERIC Educational Resources Information Center
Dolan, Thomas G.
2002-01-01
Describes how the Durant Road Middle School in Raleigh, North Carolina sets a new standard in environmental school design. "Daylighting," bringing daylight into the building for psychological, health, and energy-saving benefits, plays a central role in the design. (EV)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thayer, B.M.
A daylight office building built for Lockheed Martin near San Francisco has saved half a million dollars on energy bills and several times more due to reduced absenteeism and improved employee productivity. The building design incorporates soft daylight throughout the interior of the building. This article discusses the following topics in relationship to the building design: design for the climate; deep daylighting; integrated electric lighting; mechanical system; energy performance; the productivity story.
Advanced Lighting Controls for Reducing Energy Use and Cost in DoD Installations
2013-03-01
of advanced lighting control strategies including occupancy sensing, light tuning, daylight harvesting and proper lighting design is an effective way...details of this project and the results obtained. 15. SUBJECT TERMS Integrated lighting controls, occupancy sensing, daylight harvesting , personalized...provide energy savings through occupancy sensing, dimming and daylight harvesting . II. Dynalite is a distributed control-based, wired networked building
NASA Astrophysics Data System (ADS)
Zastrow, Armin; Wittwer, Volker
1986-09-01
The interest in efficient daylighting systems has grown recently, due to their potential for saving a considerable amount of electrical energy used for lighting purposes. In this paper we discuss the properties of daylighting systems based on either fluorescent planar concentrators and transparent light guiding plates or light pipes coated with highly reflective silver coated plastic films. Finally we give first results from a demonstration project, daylighting systems in the students' living quarters in Stuttgart-Hohenheim, which is supported by the Commission of the European Communities.
Daylighting as a design and energy strategy: Overview of opportunities and conflicts
NASA Astrophysics Data System (ADS)
Selkowitz, S.
1981-06-01
The potentials and problems associated with using daylight both to improve visual performance and interior aesthetics and to reduce electrical lighting energy consumption and peak electric loads are reviewed. Use of daylighting as a design strategy is not always synonymous with effective use of daylighting as an energy-saving strategy unless both approaches are jointly pursued by the design team. Criteria for visual performance, disability and discomfort glare, historical perspectives on daylight utilization, building form as a limit to daylight penetration, beam sunlighting strategies, luminous efficacy of daylight versus efficient electric light sources, comparative thermal impacts, peak load and load management potential, and nonenergy benefits are reviewed. Although the energy benefits of daylighting can be oversold, it is concluded that in most cases a solid understanding of the energy and design issues should produce energy efficiency and pleasing working environments.
The shift to and from daylight savings time and motor vehicle crashes.
Lambe, M; Cummings, P
2000-07-01
The objective of the study was to examine whether the shifts to and from daylight savings time in Sweden have short-term effects on the incidence of traffic crashes. A database maintained by the Swedish National Road Administration was used to examine crashes from 1984 through 1995, that occurred on state roads the Monday preceding, the Monday immediately after (index Monday), and the Monday 1 week after the change to daylight savings time in the spring and for the corresponding three Mondays in the autumn. The Mondays 1 week before and after the time changes were taken as representing the expected incidence of crashes. Crash incidence was calculated per 1000 person-years using population estimates for each year of the study. The association between 1 h of possible sleep loss and crash incidence was estimated by the incidence rate ratio from negative binomial regression. The incidence rate ratio was 1.04 (95% CI, 0.92-1.16) for a Monday on which drivers were expected to have had 1 h less sleep, compared with other Mondays. In the spring, the incidence rate ratio for crashes was 1.11 (95% CI, 0.93-1.31) for Mondays after the time change compared to other spring Mondays. The corresponding rate ratio for the fall was 0.98 (95% CI, 0.84-1.15) It was concluded that the shift to and from daylight savings time did not have measurable important immediate effects on crash incidence in Sweden.
Circadian occurrence of variceal bleeding in patients with liver cirrhosis.
Siringo, S; Bolondi, L; Sofia, S; Hermida, R C; Gramantieri, L; Gaiani, S; Piscaglia, F; Carbone, C; Misitano, B; Corinaldesi, R
1996-12-01
Several clinical events have a rhythmicity over the 24 h period. We assessed the presence of periodic rhythm in the occurrence of haematemesis in patients with liver cirrhosis under different daylight regimens, namely during standard time and during daylight savings. Over a 48 month period there were 212 consecutive admissions of 118 cirrhotics with variceal bleeding. Complete data were available for 181 episodes of bleeding: 121 (66.9%) started with haematemesis and 60 (33.1%) started with melaena. One hundred and two (56%) episodes occurred during daylight savings and 79 (44%) occurred during standard time. The cosinor test showed a 24 h biphasic peak for the occurrence of haematemesis (09.45 and 21.45 h). Moreover, a biphasic diurnal asymmetric frequency was also found by multiple component rhythmometry. The time peaks of onset of variceal haemorrhage did not change significantly during standard time and daylight savings. Patients with more than one haematemesis episode significantly bled over the same time interval. The present study confirms that over the 24 h period variceal bleeding in cirrhotic patients occurs with a predictable rhythmicity that does not seem to be under the control of the light-dark cycle. The finding of a chronorisk for variceal haemorrhage addresses specific questions for pathophysiological studies as well as for new treatment strategies.
NASA Astrophysics Data System (ADS)
Zastrow, Armin; Wittwer, Volker
1987-02-01
Efficient daylighting systems have recently attracted increasing interest due to their potential for saving a condiderable amount of electrical energy used for lighting purposes. In this paper we discuss the properties of daylighting systems based on either fluorescent planar concentrators (FPC's) and transparent light guiding plates or light pipes coated with a highly reflective silver coated plastic film (3M Silverlux film). First results on daylighting systems in the students' living quarters in Stuttgart-Hohenheim will be presented. This is a demonstration project which is supported by the Commission of the European Communities.
Hybrid daylight/light-emitting diode illumination system for indoor lighting.
Ge, Aiming; Qiu, Peng; Cai, Jinlin; Wang, Wei; Wang, Junwei
2014-03-20
A hybrid illumination method using both daylight and light-emitting diodes (LEDs) for indoor lighting is presented in this study. The daylight can be introduced into the indoor space by a panel-integration system. The daylight part and LEDs are combined within a specific luminaire that can provide uniform illumination. The LEDs can be turned on and dimmed through closed-loop control when the daylight illuminance is inadequate. We simulated the illumination and calculated the indoor lighting efficiency of our hybrid daylight and LED lighting system, and compared this with that of LED and fluorescent lighting systems. Simulation results show that the efficiency of the hybrid daylight/LED illumination method is better than that of LED and traditional lighting systems, under the same lighting conditions and lighting time; the method has hybrid lighting average energy savings of T5 66.28%, and that of the LEDs is 41.62%.
Effects of skylight parameters on daylighting energy savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arasteh, D.; Johnson, R.; Selkowitz, S.
1985-05-01
Skylight parameters that affect lighting, cooling, heating, fan, and total energy use in office buildings are examined using the state-of-the-art building energy analysis computer code, DOE-2.1B. The lighting effects of skylight spatial distribution, skylight area, skylight visible transmission, well factor, illumination setpoint, interior partitions, ceiling height, and glazing characteristics are discussed. This study serves as the foundation for the creation of a DOE-2.1B data base and design tools for estimating daylighting energy savings from skylights. 13 refs., 9 figs., 1 tab.
Ambient air conditions and variation in urban trail use.
Holmes, Ann M; Lindsey, Greg; Qiu, Chenchen
2009-11-01
This study examines the effect of air quality and administrative policies on use of urban trails in Indianapolis, IN. Attention is focused on two policy variables: (1) issuance of air pollution advisories and (2) the adoption of Daylight Savings Time. Results suggest that while trail use varies with air quality, current public advisories regarding air pollution may be of limited effectiveness in reducing trail users' exposures to hazardous pollutants. In contrast, the adoption of Daylight Savings Time was associated with a statistically significant increase in traffic levels.
From dark to bright: novel daylighting applications in solid state lighting
NASA Astrophysics Data System (ADS)
Adler, Helmar G.
2011-10-01
The term "daylighting" is used in various ways, on one hand in a more architectural sense, i.e. using existing daylight to illuminate spaces, and on the other, more recently, for using light sources to replicate daylight. The emergence of solid state lighting (SSL) opens up a large number of new avenues for daylighting. SSL allows innovative controllability of intensity and color for artificial light sources that can be advantageously applied to daylighting. With the assistance of these new technologies the combination of natural and artificial lighting could lead to improvements in energy savings and comfort of living beings. Thus it is imperative to revisit or even improve daylighting research so that building networks of the future with their sensor, energy (e.g. HVAC) and lighting requirements can benefit from the emerging capabilities. This paper will briefly review existing daylighting concepts and technology and discuss new ideas. An example of a tunable multi-color SSL system will be shown.
Hertog, W; Llenas, A; Carreras, J
2015-11-30
This article demonstrates the benefits of complementing a daylight-lit environment with a spectrally tunable illumination system. The spectral components of daylight present in the room are measured by a low-cost miniature spectrophotometer and processed through a number of optimization algorithms, carefully trading color fidelity for energy efficiency. Spectrally-tunable luminaires provide only those wavelengths that ensure that either the final illumination spectrum inside the room is kept constant or carefully follows the dynamic spectral pattern of natural daylight. Analyzing the measured data proves that such a hybrid illumination system brings both unprecendented illumination quality and significant energy savings.
Luminescent Solar Concentrator Daylighting
NASA Astrophysics Data System (ADS)
Bornstein, Jonathan G.
1984-11-01
Various systems that offer potential solutions to the problem of interior daylighting have been discussed in the literature. Virtually all of these systems rely on some method of tracking the sun along its azimuth and elevation, i.e., direct imaging of the solar disk. A simpler approach, however, involves a nontracking nonimaging device that effectively eliminates moving parts and accepts both the diffuse and direct components of solar radiation. Such an approach is based on a system that combines in a common luminaire the light emitted by luminescent solar concentrators (LSC), of the three primary colors, with a highly efficient artificial point source (HID metal halide) that automatically compensates for fluctuations in the LSC array via a daylight sensor and dimming ballast. A preliminary analysis suggests that this system could supply 90% of the lighting requirement, over the course of an 8 hour day, strictly from the daylight component under typical insolation con-ditions in the Southwest United States. In office buildings alone, the total aggregate energy savings may approach a half a quad annually. This indicates a very good potential for the realization of substantial savings in building electric energy consumption.
Energy Savings Potential of SSL in Horticultural Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stober, Kelsey; Lee, Kyung; Yamada, Mary
Report that presents the findings for horticultural lighting applications where light-emitting diode (LED) products are now competing with traditional light sources. The three main categories of indoor horticulture were investigated: supplemented greenhouses, which use electric lighting to extend the hours of daylight, supplement low levels of sunlight on cloudy days, or disrupt periods of darkness to alter plant growth; non-stacked indoor farms, where plants are grown in a single layer on the floor under ceiling-mounted lighting; and vertical farms, where plants are stacked along vertical shelving to maximize grow space, and the lighting is typically mounted within the shelving units.
Daylighting in the workplace: Two new buildings offer a guiding light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackaway, A.; Littler, J.
1996-10-01
As environmental pressures intensify and energy efficiency remains paramount, there has been renewed interest in daylighting the workplace. Interestingly, daylighting`s resurgence is being furthered by mounting evidence of occupant dissatisfaction with predominantly electrically-lit offices, and two recent reports support growing concern that the lack of daylighting in these interiors has led not only to unhappy workers, but to potentially significant reductions in workplace productivity. Clearly pressure is mounting on designers to produce buildings responding to these concerns, and as the role of precedents in the evolution of design practice is unquestioned, demand has been increasing for publication of office-based daylightingmore » case studies. In an attempt to address this need, this paper examines two recently completed British buildings in which daylight has explicitly informed the architecture, and although data concerning the resulting energy savings is not yet available, these projects currently offer the design community two excellent examples of workplace daylighting where compelling visual environments are generating noteworthy occupant satisfaction.« less
ERIC Educational Resources Information Center
Grocoff, Paul N.
This report examines both electric lighting and daylighting, listing criteria to determine the correct equipment for a school renovation or building project. Specific topics examine use of prismatic lenses; parabolic louvers; and indirect lighting, including the cost savings of using indirect lighting. The report indicates there is no clear answer…
Daylight saving time can decrease the frequency of wildlife–vehicle collisions
Ellis, William A.; FitzGibbon, Sean I.; Barth, Benjamin J.; Niehaus, Amanda C.; David, Gwendolyn K.; Taylor, Brendan D.; Matsushige, Helena; Melzer, Alistair; Bercovitch, Fred B.; Carrick, Frank; Jones, Darryl N.; Dexter, Cathryn; Gillett, Amber; Predavec, Martin; Lunney, Dan
2016-01-01
Daylight saving time (DST) could reduce collisions with wildlife by changing the timing of commuter traffic relative to the behaviour of nocturnal animals. To test this idea, we tracked wild koalas (Phascolarctos cinereus) in southeast Queensland, where koalas have declined by 80% in the last 20 years, and compared their movements with traffic patterns along roads where they are often killed. Using a simple model, we found that DST could decrease collisions with koalas by 8% on weekdays and 11% at weekends, simply by shifting the timing of traffic relative to darkness. Wildlife conservation and road safety should become part of the debate on DST. PMID:27881767
Goodman, Anna; Page, Angie S; Cooper, Ashley R
2014-10-23
It has been proposed that introducing daylight saving measures could increase children's physical activity, but there exists little research on this issue. This study therefore examined associations between time of sunset and activity levels, including using the bi-annual 'changing of the clocks' as a natural experiment. 23,188 children aged 5-16 years from 15 studies in nine countries were brought together in the International Children's Accelerometry Database. 439 of these children were of particular interest for our analyses as they contributed data both immediately before and after the clocks changed. All children provided objectively-measured physical activity data from Actigraph accelerometers, and we used their average physical activity level (accelerometer counts per minute) as our primary outcome. Date of accelerometer data collection was matched to time of sunset, and to weather characteristics including daily precipitation, humidity, wind speed and temperature. Adjusting for child and weather covariates, we found that longer evening daylight was independently associated with a small increase in daily physical activity. Consistent with a causal interpretation, the magnitude of these associations was largest in the late afternoon and early evening and these associations were also evident when comparing the same child just before and just after the clocks changed. These associations were, however, only consistently observed in the five mainland European, four English and two Australian samples (adjusted, pooled effect sizes 0.03-0.07 standard deviations per hour of additional evening daylight). In some settings there was some evidence of larger associations between daylength and physical activity in boys. There was no evidence of interactions with weight status or maternal education, and inconsistent findings for interactions with age. In Europe and Australia, evening daylight seems to play a causal role in increasing children's activity in a relatively equitable manner. Although the average increase in activity is small in absolute terms, these increases apply across all children in a population. Moreover, these small effect sizes actually compare relatively favourably with the typical effect of intensive, individual-level interventions. We therefore conclude that, by shifting the physical activity mean of the entire population, the introduction of additional daylight saving measures could yield worthwhile public health benefits.
NASA Astrophysics Data System (ADS)
Ludman, Jacques E.; Riccobono, Juanita R.; Savant, Gajendra D.; Jannson, Joanna L.; Campbell, Eugene W.; Hall, Robyn
1995-09-01
Daylighting techniques are an effective means of reducing both lighting and cooling costs; however, many of the standard techniques have flaws which reduce their effectiveness. Daylighting holograms are an efficient and effective method for diffracting sunlight up onto the ceiling, deep in a room, without diffracting the light at eye-level. They need only cover the top half of a window to produce significant energy savings. They may be used as part of a new glazing system or as a retrofit to existing windows. These holograms are broadband and are able to passively track the movement of the sun across the sky, throughout the day and year.
Daylight saving time can decrease the frequency of wildlife-vehicle collisions.
Ellis, William A; FitzGibbon, Sean I; Barth, Benjamin J; Niehaus, Amanda C; David, Gwendolyn K; Taylor, Brendan D; Matsushige, Helena; Melzer, Alistair; Bercovitch, Fred B; Carrick, Frank; Jones, Darryl N; Dexter, Cathryn; Gillett, Amber; Predavec, Martin; Lunney, Dan; Wilson, Robbie S
2016-11-01
Daylight saving time (DST) could reduce collisions with wildlife by changing the timing of commuter traffic relative to the behaviour of nocturnal animals. To test this idea, we tracked wild koalas (Phascolarctos cinereus) in southeast Queensland, where koalas have declined by 80% in the last 20 years, and compared their movements with traffic patterns along roads where they are often killed. Using a simple model, we found that DST could decrease collisions with koalas by 8% on weekdays and 11% at weekends, simply by shifting the timing of traffic relative to darkness. Wildlife conservation and road safety should become part of the debate on DST. © 2016 The Author(s).
Solar Glazing Tips for School Construction
ERIC Educational Resources Information Center
Smith, Jonathan
2012-01-01
Glazing can be optimized to enhance passive solar heating and daylight harvesting by exceeding the prescriptive limits of the energy code. This savings can be garnered without the high cost of external overhangs or expensive glazing products. The majority of savings from solar glazing are attributable to the increase in solar heating and…
Impact of daylight savings time on spontaneous pregnancy loss in in vitro fertilization patients.
Liu, Constance; Politch, Joseph A; Cullerton, Evan; Go, Kathryn; Pang, Samuel; Kuohung, Wendy
2017-01-01
Transition into daylight savings time (DST) has studied negative impacts on health, but little is known regarding impact on fertility. This retrospective cohort study evaluates DST impact on pregnancy and pregnancy loss rates in 1,654 autologous in vitro fertilization cycles (2009 to 2012). Study groups were identified based on the relationship of DST to embryo transfer. Pregnancy rates were similar in Spring and Fall (41.4%, 42.2%). Pregnancy loss rates were also comparable between Spring and Fall (15.5%, 17.1%), but rates of loss were significantly higher in Spring when DST occurred after embryo transfer (24.3%). Loss was marked in patients with a history of prior spontaneous pregnancy loss (60.5%).
LeRoy Doggett and Daylight Saving Time: A Reminiscence
NASA Astrophysics Data System (ADS)
Bartky, I. R.
1997-12-01
Daylight Saving Time (DST) has been a concern of Congress ever since its adoption in 1918. Yet, not until 1976 did Members of Congress have astronomical, geographic and demographic information in terms of the country's Standard Time zones. This information and various impact analyses were developed by the National Bureau of Standards (NBS) at the request of the House of Representatives, which was reviewing the effects of a two-year, DST experiment on the American public. The displays in the study gave legislators a way to consider alternate observance periods in a systematic manner. The leader of the DST study team will detail LeRoy Doggett's involvement during the hectic, three-month analysis period that culminated with NBS officials testifying before Congress.
Optical characterization of fritted glass for architectural applications
NASA Astrophysics Data System (ADS)
Jonsson, Jacob C.; Rubin, Michael D.; Nilsson, Annica M.; Jonsson, Andreas; Roos, Arne
2009-04-01
Fritted glass is commonly used as a light diffusing element in modern buildings. Traditionally it has been used for aesthetic purposes but it can also be used for energy savings by incorporating it in novel daylighting systems? To answer such questions the light scattering properties must be properly characterized. This paper contains measurements of different varieties of fritted glass, ranging from the simplest direct-hemispherical measurements to angle-resolved goniometer measurements. Modeling the light scattering to obtain the full bidirectional scattering distribution function (BSDF) extends the measured data, making it useful in simulation programs such as Window 6 and Radiance. Surface profilometry results and SEM micrographs are included to demonstrate the surface properties of the samples studied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Eleanor S.; Thanachareonkit, Anothai; Touzani, Samir
The objective of this monitored field study was to identify near-term innovative façade technologies for solar control and daylighting with a goal of 20-40% energy use savings below Title 24 2013 in the 30-ft deep perimeter zone near vertical windows within cost and comfort constraints. The targeted market was new or existing commercial office buildings or buildings with similar patterns of use.
Hester, Nathan; Li, Ke; Schramski, John R; Crittenden, John
2012-04-30
Globally, residential energy consumption continues to rise due to a variety of trends such as increasing access to modern appliances, overall population growth, and the overall increase of electricity distribution. Currently, residential energy consumption accounts for approximately one-fifth of total U.S. energy consumption. This research analyzes the effectiveness of a range of energy-saving measures for residential houses in semi-arid climates. These energy-saving measures include: structural insulated panels (SIP) for exterior wall construction, daylight control, increased window area, efficient window glass suitable for the local weather, and several combinations of these. Our model determined that energy consumption is reduced by up to 6.1% when multiple energy savings technologies are combined. In addition, pre-construction technologies (structural insulated panels (SIPs), daylight control, and increased window area) provide roughly 4 times the energy savings when compared to post-construction technologies (window blinds and efficient window glass). The model also illuminated the importance variations in local climate and building configuration; highlighting the site-specific nature of this type of energy consumption quantification for policy and building code considerations. Published by Elsevier Ltd.
Energy performance and savings potentials with skylights
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arasteh, D.; Johnson, R.; Selkowitz, S.
1984-12-01
This study systematically explores the energy effects of skylight systems in a prototypical office building module and examines the savings from daylighting. For specific climates, roof/skylight characteristics are identified that minimize total energy or peak electrical demand. Simplified techniques for energy performance calculation are also presented based on a multiple regression analysis of our data base so that one may easily evaluate daylighting's effects on total and component energy loads and electrical peaks. This provides additional insights into the influence of skylight parameters on energy consumption and electrical peaks. We use the DOE-2.1B energy analysis program with newly incorporated daylightingmore » algorithms to determine hourly, monthly, and annual impacts of daylighting strategies on electrical lighting consumption, cooling, heating, fan power, peak electrical demands, and total energy use. A data base of more than 2000 parametric simulations for 14 US climates has been generated. Parameters varied include skylight-to-roof ratio, shading coefficient, visible transmittance, skylight well light loss, electric lighting power density, roof heat transfer coefficient, and electric lighting control type. 14 references, 13 figures, 4 tables.« less
The integration of daylighting with artificial lighting to enhance building energy performance
NASA Astrophysics Data System (ADS)
Al-Ashwal, Najib Taher; Hassan, Ahmad Sanusi
2017-10-01
In sustainable building designs, daylight is considered as an alternative source of light to artificial lighting. Daylight is an energy-free and efficient-cost lighting source. Natural light is the best source for light due to its good quality, which matches the visual response of the human eyes. Daylight positively affects people by providing a sense of liveliness and brightness in the living space. The positive impact of daylight on the building occupants' visual comfort, health and performance is well recognized. However, daylight is not widely utilized to supplement artificial lighting, because there is a lack of information and tools to evaluate daylighting and potentials for energy savings. The efficient utilization of natural lighting will not only affect the interior environment and the occupants' health and performance but also has a direct impact on the building energy performance. Therefore, this paper reviews and discusses the effects of daylighting on the building energy performance mainly in schools and office buildings. This includes lighting energy performance, total energy consumption, cooling load. The methods, which are used to estimate the possible reduction in total energy consumption, are also reviewed in this research paper. Previous studies revealed that a clear reduction can be obtained in the energy consumed by electric lighting, as well as in the total energy end-use when a suitable lighting control system is applied to utilize the available natural light.
Window performance and building energy use: Some technical options for increasing energy efficiency
NASA Astrophysics Data System (ADS)
Selkowitz, Stephen
1985-11-01
Window system design and operation has a major impact on energy use in buildings as well as on occupants' thermal and visual comfort. Window performance will be a function of optical and thermal properties, window management strategies, climate and orientation, and building type and occupancy. In residences, heat loss control is a primary concern, followed by sun control in more southerly climates. In commercial buildings, the daylight provided by windows may be the major energy benefits but solar gain must be controlled so that increased cooling loads do not exceed daylighting savings. Reductions in peak electrical demand and HVAC system size may also be possible in well-designed daylighted buildings.
76 FR 18467 - Pattern of Violations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-04
... Eastern Daylight Savings Time on April 18, 2011. ADDRESSES: Submit comments by any of the following... proposed rule addressing Pattern of Violations (POV). This extension gives commenters additional time to...
Wagner, David T; Barnes, Christopher M; Lim, Vivien K G; Ferris, D Lance
2012-09-01
The Internet is a powerful tool that has changed the way people work. However, the ubiquity of the Internet has led to a new workplace threat to productivity-cyberloafing. Building on the ego depletion model of self-regulation, we examine how lost and low-quality sleep influence employee cyberloafing behaviors and how individual differences in conscientiousness moderate these effects. We also demonstrate that the shift to Daylight Saving Time (DST) results in a dramatic increase in cyberloafing behavior at the national level. We first tested the DST-cyberloafing relation through a national quasi-experiment, then directly tested the relation between sleep and cyberloafing in a closely controlled laboratory setting. We discuss the implications of our findings for theory, practice, and future research.
NASA Astrophysics Data System (ADS)
Granderson, Jessica Ann
2007-12-01
The need for sustainable, efficient energy systems is the motivation that drove this research, which targeted the design of an intelligent commercial lighting system. Lighting in commercial buildings consumes approximately 13% of all the electricity generated in the US. Advanced lighting controls1 intended for use in commercial office spaces have proven to save up to 45% in electricity consumption. However, they currently comprise only a fraction of the market share, resulting in a missed opportunity to conserve energy. The research goals driving this dissertation relate directly to barriers hindering widespread adoption---increase user satisfaction, and provide increased energy savings through more sophisticated control. To satisfy these goals an influence diagram was developed to perform daylighting actuation. This algorithm was designed to balance the potentially conflicting lighting preferences of building occupants, with the efficiency desires of building facilities management. A supervisory control policy was designed to implement load shedding under a demand response tariff. Such tariffs offer incentives for customers to reduce their consumption during periods of peak demand, trough price reductions. In developing the value function occupant user testing was conducted to determine that computer and paper tasks require different illuminance levels, and that user preferences are sufficiently consistent to attain statistical significance. Approximately ten facilities managers were also interviewed and surveyed to isolate their lighting preferences with respect to measures of lighting quality and energy savings. Results from both simulation and physical implementation and user testing indicate that the intelligent controller can increase occupant satisfaction, efficiency, cost savings, and management satisfaction, with respect to existing commercial daylighting systems. Several important contributions were realized by satisfying the research goals. A general model of a daylighted environment was designed, and a practical means of user preference identification was defined. Further, a set of general procedures were identified for the design of human-centered sensor-based decision-analytic systems, and for the identification of the allowable uncertainty in nodes of interest. To confirm generality, a vehicle health monitoring problem was defined and solved using these two procedures. 1'Daylighting' systems use sensors to determine room occupancy and available sunlight, and automatically dim the lights in response.
Literature Review of the Effects of Natural Light on Building Occupants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, L.; Torcellini, P.
This paper presents summary findings from a literature search of the term ''daylighting''-using natural light in a building to offset or replace electric lighting. According to the Department of Energy's Office of Building Technology, State and Community Programs 2000 BTS Core Databook, in 1998, commercial buildings consumed 32% of the total electricity in the United States, of which more than one-third went to lighting. Using daylighting systems and turning off the lights will help reduce this energy load. Electrical lighting adds to both the electrical and cooling loads in a commercial building. Utility costs can be decreased when daylighting ismore » properly designed to replace electrical lighting. Along with the importance of energy savings, studies have demonstrated the non-energy-related benefits of daylighting. We compiled the data from books, periodicals, Internet articles, and interviews. The books, periodicals, and Internet articles provided the background information used to identify the main subjects of the paper. The interviews provided us with details related to specific buildings and companies that have integrated daylighting into their buildings.« less
34 CFR 101.33 - Filing and service.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... to 5:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only on exhibits and transcripts of testimony need be filed. For...
ERIC Educational Resources Information Center
Raloff, Janet
1978-01-01
Presented are different research program developments aimed at reducing the consumption of electrical energy for artificial lights. Explains the idea of the dimmers, where the amount of incoming daylight regulates the current needed for the lamp. (GA)
34 CFR 101.33 - Filing and service.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... to 5:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only on exhibits and transcripts of testimony need be filed. For...
34 CFR 101.33 - Filing and service.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... to 5:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only on exhibits and transcripts of testimony need be filed. For...
34 CFR 101.33 - Filing and service.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... to 5:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only on exhibits and transcripts of testimony need be filed. For...
34 CFR 101.33 - Filing and service.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... to 5:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only on exhibits and transcripts of testimony need be filed. For...
17 CFR 171.3 - Business address; hours.
Code of Federal Regulations, 2014 CFR
2014-04-01
.... until 4:45 p.m., eastern standard time or eastern daylight savings time, whichever is currently in effect in Washington, DC. [55 FR 41068, Oct. 9, 1990, as amended at 60 FR 49336, Sept. 25, 1995] ...
Development of Design Guidance for K-12 Schools from 30% to 50% Energy Savings: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pless, S.; Torcellini, P.; Long, N.
2008-07-01
This paper describes the development of energy efficiency recommendations for achieving 30% whole-building energy savings in K-12 schools over levels achieved by following the ANSI/ASHRAE/IESNA Standard 90.1. These design recommendations look at building envelope, fenestration, lighting systems (including electrical lights and daylighting), HVAC systems, building automation and controls, outside air treatment, and service water heating.
A sensor-less LED dimming system based on daylight harvesting with BIPV systems.
Yoo, Seunghwan; Kim, Jonghun; Jang, Cheol-Yong; Jeong, Hakgeun
2014-01-13
Artificial lighting in office buildings typically requires 30% of the total energy consumption of the building, providing a substantial opportunity for energy savings. To reduce the energy consumed by indoor lighting, we propose a sensor-less light-emitting diode (LED) dimming system using daylight harvesting. In this study, we used light simulation software to quantify and visualize daylight, and analyzed the correlation between photovoltaic (PV) power generation and indoor illumination in an office with an integrated PV system. In addition, we calculated the distribution of daylight illumination into the office and dimming ratios for the individual control of LED lights. Also, we were able directly to use the electric power generated by PV system. As a result, power consumption for electric lighting was reduced by 40 - 70% depending on the season and the weather conditions. Thus, the dimming system proposed in this study can be used to control electric lighting to reduce energy use cost-effectively and simply.
2009-03-26
annually ( McHugh , et al., 1998). USAF has used daylighting as an energy savings strategy in earlier studies (Holtz, 1990); and is pursuing it to meet...using renewable energy to generate electricity ( McHugh , et al., 1998). For example, traditional utility systems that are straining to meet peak...1998) found that lighting accounts for 40-50% of commercial energy consumption and McHugh , Burns, and Hittle (1998) stated that electric lighting and
A computer program for analyzing the energy consumption of automatically controlled lighting systems
NASA Astrophysics Data System (ADS)
1982-01-01
A computer code to predict the performance of controlled lighting systems with respect to their energy saving capabilities is presented. The computer program provides a mathematical model from which comparisons of control schemes can be made on an economic basis only. The program does not calculate daylighting, but uses daylighting values as input. The program can analyze any of three power input versus light output relationships, continuous dimming with a linear response, continuous dimming with a nonlinear response, or discrete stepped response. Any of these options can be used with or without daylighting, making six distinct modes of control system operation. These relationships are described in detail. The major components of the program are discussed and examples are included to explain how to run the program.
21 CFR 1316.45 - Filings; address; hours.
Code of Federal Regulations, 2014 CFR
2014-04-01
... through Friday from 8:30 a.m. to 5 p.m. eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time, except on national legal holidays. Documents shall be dated...
21 CFR 1316.45 - Filings; address; hours.
Code of Federal Regulations, 2012 CFR
2012-04-01
... through Friday from 8:30 a.m. to 5 p.m. eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time, except on national legal holidays. Documents shall be dated...
21 CFR 1316.45 - Filings; address; hours.
Code of Federal Regulations, 2011 CFR
2011-04-01
... through Friday from 8:30 a.m. to 5 p.m. eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time, except on national legal holidays. Documents shall be dated...
21 CFR 1316.45 - Filings; address; hours.
Code of Federal Regulations, 2013 CFR
2013-04-01
... through Friday from 8:30 a.m. to 5 p.m. eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time, except on national legal holidays. Documents shall be dated...
12 CFR 11.3 - Filing requirements and inspection of documents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... submitted by direct transmission on or before 10 p.m. Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4) Mandatory compliance...
12 CFR 11.3 - Filing requirements and inspection of documents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... submitted by direct transmission on or before 10 p.m. Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4) Mandatory compliance...
12 CFR 11.3 - Filing requirements and inspection of documents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... submitted by direct transmission on or before 10 p.m. Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4) Mandatory compliance...
12 CFR 11.3 - Filing requirements and inspection of documents.
Code of Federal Regulations, 2013 CFR
2013-01-01
... submitted by direct transmission on or before 10 p.m. Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4) Mandatory compliance...
36 CFR 1150.23 - Filing and service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... legal holidays excepted) from 9 a.m. to 5:30 p.m. Standard or Daylight Savings Time, whichever is effective in the city where the office of the judge is located at the time. (c) Service. Service of one copy...
38 CFR 18b.22 - Filing and service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... excepted) from 8 a.m. to 4:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only of exhibits and transcripts of testimony need be filed...
38 CFR 18b.22 - Filing and service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... excepted) from 8 a.m. to 4:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only of exhibits and transcripts of testimony need be filed...
38 CFR 18b.22 - Filing and service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... excepted) from 8 a.m. to 4:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only of exhibits and transcripts of testimony need be filed...
36 CFR 1150.23 - Filing and service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... legal holidays excepted) from 9 a.m. to 5:30 p.m. Standard or Daylight Savings Time, whichever is effective in the city where the office of the judge is located at the time. (c) Service. Service of one copy...
36 CFR 1150.23 - Filing and service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... legal holidays excepted) from 9 a.m. to 5:30 p.m. Standard or Daylight Savings Time, whichever is effective in the city where the office of the judge is located at the time. (c) Service. Service of one copy...
38 CFR 18b.22 - Filing and service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... excepted) from 8 a.m. to 4:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only of exhibits and transcripts of testimony need be filed...
38 CFR 18b.22 - Filing and service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... excepted) from 8 a.m. to 4:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only of exhibits and transcripts of testimony need be filed...
36 CFR 1150.23 - Filing and service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... legal holidays excepted) from 9 a.m. to 5:30 p.m. Standard or Daylight Savings Time, whichever is effective in the city where the office of the judge is located at the time. (c) Service. Service of one copy...
17 CFR 230.459 - Calculation of effective date.
Code of Federal Regulations, 2010 CFR
2010-04-01
... of 24 hours each from 5:30 p.m. eastern standard time or eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date of filing. [Reg. C, 12 FR 4075, June...
17 CFR 230.459 - Calculation of effective date.
Code of Federal Regulations, 2011 CFR
2011-04-01
... of 24 hours each from 5:30 p.m. eastern standard time or eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date of filing. [Reg. C, 12 FR 4075, June...
17 CFR 230.459 - Calculation of effective date.
Code of Federal Regulations, 2014 CFR
2014-04-01
... of 24 hours each from 5:30 p.m. eastern standard time or eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date of filing. [Reg. C, 12 FR 4075, June...
17 CFR 230.459 - Calculation of effective date.
Code of Federal Regulations, 2012 CFR
2012-04-01
... of 24 hours each from 5:30 p.m. eastern standard time or eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date of filing. [Reg. C, 12 FR 4075, June...
17 CFR 230.459 - Calculation of effective date.
Code of Federal Regulations, 2013 CFR
2013-04-01
... of 24 hours each from 5:30 p.m. eastern standard time or eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date of filing. [Reg. C, 12 FR 4075, June...
ERIC Educational Resources Information Center
Shimm, Jon
2001-01-01
Discusses how incorporating energy-efficient features into residence halls can save money and make students' campus experience more enjoyable. Use of heat-recovery systems, low-impact lighting, and natural daylighting are explored as are ideas to consider for future residence hall construction projects or renovations. (GR)
36 CFR § 1150.23 - Filing and service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (Federal legal holidays excepted) from 9 a.m. to 5:30 p.m. Standard or Daylight Savings Time, whichever is effective in the city where the office of the judge is located at the time. (c) Service. Service of one copy...
NASA Astrophysics Data System (ADS)
Linhart, Friedrich; Wittkopf, Stephen K.; Münch, Mirjam; Scartezzini, Jean-Louis
2009-08-01
Making daylight more available in buildings is highly desirable for reasons of energy efficiency, visual comfort, occupant well-being and health. The Anidolic Integrated Ceiling (AIC) is a highly efficient daylighting system, designed to gather and redirect daylight from the outside of a building into its interior with minimal losses. The reflective coating materials used within AICs have a major impact on the optical efficiency of such systems. The first part of our article presents a new computer model of an AIC consisting of more than 30 distinct components. We discuss on which of them the use of expensive, highly reflective coatings makes the most sense. We conclude that coating the component "Anidolic element 1" is always a good choice and that considerable financial savings can be obtained by following an appropriate optimization sequence.The second part of our article discusses chronobiological properties of Anidolic Daylighting Systems (ADS). We recorded daytime irradiance values for several weeks from March to May 2009 in an experimental office setup in our laboratory using a portable digital spectroradiometer. Our results showed to which extent different sky conditions influenced daylight exposure of office workers in an ADS-equipped office room. We conclude that for the tested ADS-equipped office room, daylight supply can be considered largely sufficient during long periods on most working days. However, complementary artificial lighting with blue-enriched polychromatic fluorescent tubes might be useful on days with predominantly overcast skies as well as before 09:00 and after 16:30 on all days.
Development of Design Guidance for K-12 Schools: From 30% to 50% Energy Savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pless, S.; Torcellini, P.; Long, N.
2008-01-01
This paper describes the development of energy efficiency recommendations for achieving 30% whole-building energy savings in K-12 Schools over levels achieved by following the ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings (1999 and 2004 versions). Exhaustive simulations were run to create packages of energy design solutions available over a wide range of K-12 schools and climates. These design recommendations look at building envelope, fenestration, lighting systems (including electrical lights and daylighting), HVAC systems, building automation and controls, outside air treatment, and service water heating. We document and discuss the energy modeling performed to demonstrate that themore » recommendations will result in at least 30% energy savings over ASHRAE 90.1-1999 and ASHRAE 90.1-2004. Recommendations are evaluated based on the availability of daylighting for the school and by the type of HVAC system. Compared to the ASHRAE 90.1-1999 baseline, the recommendations result in more than 30% savings in all climate zones for both daylit and nondaylit elementary, middle, and high schools with a range of HVAC system types. These recommendations have been included in the Advanced Energy Design Guide for K-12 School Buildings. Compared to the more stringent ASHRAE 90.1-2004 baseline, the recommendations result in more than 30% savings in all climate zones, for only the daylit elementary, middle, and high schools, with a range of HVAC system types. To inform the future development of recommendations for higher level of energy savings, we analyzed a subset of recommendations to understand which energy efficiency technologies would be needed to achieve 50% energy savings.« less
Lighting the School of the Future.
ERIC Educational Resources Information Center
Clanton, Nancy
1999-01-01
Discusses the Austin Independent School District's (Texas) school redesign efforts to allow more daylight in its schools, increase the students' comfort and productivity, and lower utility costs. Return on investment potential from savings in maintenance, replacement, and productivity of the school are highlighted. (GR)
Variation of outdoor illumination as a function of solar elevation and light pollution
NASA Astrophysics Data System (ADS)
Spitschan, Manuel; Aguirre, Geoffrey K.; Brainard, David H.; Sweeney, Alison M.
2016-06-01
The illumination of the environment undergoes both intensity and spectral changes during the 24 h cycle of a day. Daylight spectral power distributions are well described by low-dimensional models such as the CIE (Commission Internationale de l’Éclairage) daylight model, but the performance of this model in non-daylight regimes is not characterised. We measured downwelling spectral irradiance across multiple days in two locations in North America: One rural location (Cherry Springs State Park, PA) with minimal anthropogenic light sources, and one city location (Philadelphia, PA). We characterise the spectral, intensity and colour changes and extend the existing CIE model for daylight to capture twilight components and the spectrum of the night sky.
Variation of outdoor illumination as a function of solar elevation and light pollution
Spitschan, Manuel; Aguirre, Geoffrey K.; Brainard, David H.; Sweeney, Alison M.
2016-01-01
The illumination of the environment undergoes both intensity and spectral changes during the 24 h cycle of a day. Daylight spectral power distributions are well described by low-dimensional models such as the CIE (Commission Internationale de l’Éclairage) daylight model, but the performance of this model in non-daylight regimes is not characterised. We measured downwelling spectral irradiance across multiple days in two locations in North America: One rural location (Cherry Springs State Park, PA) with minimal anthropogenic light sources, and one city location (Philadelphia, PA). We characterise the spectral, intensity and colour changes and extend the existing CIE model for daylight to capture twilight components and the spectrum of the night sky. PMID:27272736
Variation of outdoor illumination as a function of solar elevation and light pollution.
Spitschan, Manuel; Aguirre, Geoffrey K; Brainard, David H; Sweeney, Alison M
2016-06-07
The illumination of the environment undergoes both intensity and spectral changes during the 24 h cycle of a day. Daylight spectral power distributions are well described by low-dimensional models such as the CIE (Commission Internationale de l'Éclairage) daylight model, but the performance of this model in non-daylight regimes is not characterised. We measured downwelling spectral irradiance across multiple days in two locations in North America: One rural location (Cherry Springs State Park, PA) with minimal anthropogenic light sources, and one city location (Philadelphia, PA). We characterise the spectral, intensity and colour changes and extend the existing CIE model for daylight to capture twilight components and the spectrum of the night sky.
Aldasouqi, Saleh A; Reed, Amy J
2014-11-01
The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients' visits, and should remind their patients to always verify these settings. © 2014 Diabetes Technology Society.
Adverse Effects of Daylight Saving Time on Adolescents' Sleep and Vigilance
Medina, Diana; Ebben, Matthew; Milrad, Sara; Atkinson, Brianna; Krieger, Ana C.
2015-01-01
Study Objectives: Daylight saving time (DST) has been established with the intent to reduce energy expenditure, however unintentional effects on sleep and vigilance have not been consistently measured. The objective of this study was to test the hypothesis that DST adversely affects high school students' sleep and vigilance on the school days following its implementation. Methods: A natural experiment design was used to assess baseline and post-DST differences in objective and subjective measures of sleep and vigilance by actigraphy, sleep diary, sleepiness scale, and psychomotor vigilance testing (PVT). Students were tested during school days immediately preceding and following DST. Results: A total of 40 high school students were enrolled in this study; 35 completed the protocol. Sleep duration declined by an average of 32 minutes on the weeknights post-DST, reflecting a cumulative sleep loss of 2 h 42 min as compared to the baseline week (p = 0.001). This finding was confirmed by sleep diary analyses, reflecting an average sleep loss of 27 min/night (p = 0.004) post-DST. Vigilance significantly deteriorated, with a decline in PVT performance post-DST, resulting in longer reaction times (p < 0.001) and increased lapses (p < 0.001). Increased daytime sleepiness was also demonstrated (p < 0.001). Conclusions: The early March DST onset adversely affected sleep and vigilance in high school students resulting in increased daytime sleepiness. Larger scale evaluations of sleep impairments related to DST are needed to further quantify this problem in the population. If confirmed, measures to attenuate sleep loss post-DST should be implemented. Citation: Medina D, Ebben M, Milrad S, Atkinson B, Krieger AC. Adverse effects of daylight saving time on adolescents' sleep and vigilance. J Clin Sleep Med 2015;11(8):879–884. PMID:25979095
Pitfalls of Insulin Pump Clocks
Reed, Amy J.
2014-01-01
The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients’ visits, and should remind their patients to always verify these settings. PMID:25355713
NASA Astrophysics Data System (ADS)
Smith, Geoffrey B.; Earp, Alan; Franklin, Jim B.; McCredie, Geoffrey
2001-11-01
Simple quantitative performance criteria are developed for translucent materials in terms of hemispherical visible transmittance, and angular spread of transmitted luminance using a half angle. Criteria are linked to applications in luminaires and skylights with emphasis on maximising visible throughput while minimising glare. These basic criteria are also extended to angle of incidence changes which are substantial. Example data is provided showing that acrylic pigmented with spherical polymer particles can have total hemispherical transmittance with weak thickness dependence, which is better than clear sheet, while the spread of transmitted light is quite thickness-sensitive and occurs over wider angles than inorganic pigments. This combination means significantly fewer lamps can achieve specified lux levels with low glare, and smaller skylights can provide higher, more uniform daylight illuminance.
Power, Politics and Purchasing.
ERIC Educational Resources Information Center
Moore, Deborah P.
2000-01-01
Explores the overlapping of energy efficiency, budget-cutting, and facility needs in K-12 schools. Utilities expenditures in schools are discussed for electricity and natural gas as are energy-saving alternatives such as daylighting, solar energy, wind production of power, and geothermal energy. Sources for further information conclude the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
This LEED Platinum home was built on the site of a 60-year-old bungalow that was demolished. It boasts views of Candlewood Lake, a great deal of daylight, and projected annual energy savings of almost $3,000. This home was awarded a 2013 Housing Innovation Award in the custom builder category.
75 FR 41239 - Sunshine Act; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-15
... LEGAL SERVICES CORPORATION Sunshine Act; Notice of Meeting TIME AND DATE: The Legal Services Corporation Board of Directors' Search Committee for LSC President (``Search Committee'' or ``Committee'') will meet on July 20, 2010. The meeting will begin at 4 p.m. (Central Daylight Savings Time) and...
77 FR 22666 - Payment System Risk Policy; Daylight Overdraft Posting Rules
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-17
... of separately-sorted savings bonds and to eliminate a reference to the contractual clearing balance... clearing balance program are effective July 12, 2012. FOR FURTHER INFORMATION CONTACT: Susan V. Foley... account balances according to a set of ``posting rules'' that determine the intraday timing of debits and...
75 FR 35801 - Meeting of the National Drinking Water Advisory Council-Notice of Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-23
... a.m. to noon, Eastern Daylight Savings Time. ADDRESSES: The meeting will be held at the Hotel... ensure adequate time for public involvement, individuals or organizations interested in presenting an... to give EPA as much time as possible to process your request. Dated: June 17, 2010. Cynthia C...
17 CFR 260.7a-4 - Calculation of time.
Code of Federal Regulations, 2010 CFR
2010-04-01
... eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Calculation of time. 260.7a-4... time. Saturdays, Sundays and holidays shall be counted in computing the effective date of applications...
49 CFR 71.2 - Annual advancement of standard time.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., requires that the standard time of each State observing Daylight Saving Time shall be advanced 1 hour... 49 Transportation 1 2012-10-01 2012-10-01 false Annual advancement of standard time. 71.2 Section 71.2 Transportation Office of the Secretary of Transportation STANDARD TIME ZONE BOUNDARIES § 71.2...
Code of Federal Regulations, 2013 CFR
2013-04-01
... means any hour between 8:15 a.m. and 4:45 p.m. Business day and business hour are Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect in Washington, DC, on all days... ENTITIES § 40.1 Definitions. As used in this part: (a) Business day means the intraday period of time...
Code of Federal Regulations, 2012 CFR
2012-04-01
... means any hour between 8:15 a.m. and 4:45 p.m. Business day and business hour are Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect in Washington, DC, on all days... ENTITIES § 40.1 Definitions. As used in this part: (a) Business day means the intraday period of time...
17 CFR 260.7a-4 - Calculation of time.
Code of Federal Regulations, 2014 CFR
2014-04-01
... eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date... 17 Commodity and Securities Exchanges 4 2014-04-01 2014-04-01 false Calculation of time. 260.7a-4... time. Saturdays, Sundays and holidays shall be counted in computing the effective date of applications...
17 CFR 260.7a-4 - Calculation of time.
Code of Federal Regulations, 2013 CFR
2013-04-01
... eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date... 17 Commodity and Securities Exchanges 3 2013-04-01 2013-04-01 false Calculation of time. 260.7a-4... time. Saturdays, Sundays and holidays shall be counted in computing the effective date of applications...
Code of Federal Regulations, 2014 CFR
2014-04-01
... means any hour between 8:15 a.m. and 4:45 p.m. Business day and business hour are Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect in Washington, DC, on all days... ENTITIES § 40.1 Definitions. As used in this part: (a) Business day means the intraday period of time...
49 CFR 71.2 - Annual advancement of standard time.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., requires that the standard time of each State observing Daylight Saving Time shall be advanced 1 hour... 49 Transportation 1 2014-10-01 2014-10-01 false Annual advancement of standard time. 71.2 Section 71.2 Transportation Office of the Secretary of Transportation STANDARD TIME ZONE BOUNDARIES § 71.2...
49 CFR 71.2 - Annual advancement of standard time.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., requires that the standard time of each State observing Daylight Saving Time shall be advanced 1 hour... 49 Transportation 1 2013-10-01 2013-10-01 false Annual advancement of standard time. 71.2 Section 71.2 Transportation Office of the Secretary of Transportation STANDARD TIME ZONE BOUNDARIES § 71.2...
49 CFR 71.2 - Annual advancement of standard time.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., requires that the standard time of each State observing Daylight Saving Time shall be advanced 1 hour... 49 Transportation 1 2011-10-01 2011-10-01 false Annual advancement of standard time. 71.2 Section 71.2 Transportation Office of the Secretary of Transportation STANDARD TIME ZONE BOUNDARIES § 71.2...
17 CFR 260.7a-4 - Calculation of time.
Code of Federal Regulations, 2011 CFR
2011-04-01
... eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date... 17 Commodity and Securities Exchanges 3 2011-04-01 2011-04-01 false Calculation of time. 260.7a-4... time. Saturdays, Sundays and holidays shall be counted in computing the effective date of applications...
17 CFR 260.7a-4 - Calculation of time.
Code of Federal Regulations, 2012 CFR
2012-04-01
... eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date... 17 Commodity and Securities Exchanges 3 2012-04-01 2012-04-01 false Calculation of time. 260.7a-4... time. Saturdays, Sundays and holidays shall be counted in computing the effective date of applications...
NASA Astrophysics Data System (ADS)
Ekasiwi, S. N. N.; Antaryama, I. G. N.; Krisdianto, J.; Ulum, M. S.
2018-03-01
Classrooms in educational buildings require certain lighting requirements to serve teaching and learning activities during daytime. The most typical design is double sided opening in order to get good daylight distribution in the classroom. Using artificial light is essential to contribute the worse daylight condition. A short observation indicates that during the lecture time the light turned on, even in the daytime. That might result in wasting electrical energy. The aim of the study is to examine the type of classroom, which perform comfortable lighting environment as well as saving energy. This paper reports preliminary results of the study obtained from field observation and measurements. The use of energy and usage pattern of artificial lighting during the lecture is recorded and then the data evaluated to see the suitability of existing energy use to building energy standards. The daylighting design aspects have to be the first consideration. However, the similarity in WWR of the classroom, the Daylight Factor (DF) may differ. It depends on the room depth. The similarity of the increase of WWR and Ratio of openings to floor area do not directly correspond to the increase of DF. The outdoor condition of larger daylight access and the room depth are the influencing factors. Despite the similarity of physical type, usage pattern of the classroom imply the use of electrical energy for lighting. The results indicate the factors influencing lighting energy performance in correlation to their typologies
ADASY (Active Daylighting System)
NASA Astrophysics Data System (ADS)
Vázquez-Moliní, Daniel; González-Montes, Mario; Fernández-Balbuena, Antonio Á.; Bernabéu, Eusebio; García-Botella, Ángel; García-Rodríguez, Lucas; Pohl, Wilfried
2009-08-01
The main objective of ADASY (Active Daylighting System) work is to design a façade static daylighting system oriented to office applications, mainly. The goal of the project is to save energy by guiding daylight into a building for lighting purpose. With this approach we can reduce the electrical load for artificial lighting, completing it with sustainable energy. The collector of the system is integrated on a vertical façade and its distribution guide is always horizontal inside of the false ceiling. ADASY is designed with a specific patent pending caption system, a modular light-guide and light extractor luminaire system. Special care has been put on the final cost of the system and its building integration purpose. The current ADASY configuration is able to illuminate 40 m2 area with a 300lx-400lx level in the mid time work hours; furthermore it has a good enough spatial uniformity distribution and a controlled glare. The data presented in this study are the result of simulation models and have been confirmed by a physical scaled prototype. ADASY's main advantages over regular illumination systems are: -Low maintenance; it has not mobile pieces and therefore it lasts for a long time and require little attention once installed. - No energy consumption; solar light continue working even if there has been a power outage. - High quality of light: the colour rendering of light is very high - Psychological benefits: People working with daylight get less stress and more comfort, increasing productivity. - Health benefits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffmann, Sabine; Lee, Eleanor
Exterior shades are highly efficient for reducing solar load in commercial buildings. Their impact on net energy use depends on the annual energy balance of heating, cooling, fan and lighting energy. This paper discusses the overall energy use intensity of various external shading systems for a prototypical large office building split into the different types of energy use and for different orientations and window sizes. Lighting energy was calculated for a constant lighting power as well as for dimmed lighting fixtures (daylighting control). In Section 3, slat angles and solar cut-off angles were varied for fixed exterior slat shading systems.more » While the most light-blocking shades performed best for the case without daylighting controls, the optimum cut-off angle with daylighting controls was found to be 30 deg for the office building prototype used in Chicago and Houston. For large window-to-wall (WWR) ratios, window related annual energy use could be reduced by at least 70 % without daylighting control and by a minimum of 86 % with daylighting control in average over all orientations. The occurrence of discomfort glare was is considered in Section 4 of the paper, which looks at the performance of commercially available exterior shading systems when an interior shade is used in addition to the exterior shade during hours when occupants would experience discomfort glare. Glare control impacts overall energy use intensity significantly for exterior shades with high transmittance, especially when daylighting controls are used. In these cases, exterior shades are only beneficial for window-to-wall areas ≥ 45% in the hot Houston climate. For smaller windows and in a heating/cooling climate like Chicago, exterior shades can increase energy consumption« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, T.
1997-12-31
As part of the ACT{sup 2} project, sponsored by a major northern California utility, two occupied single-story commercial buildings were equipped with similar yet different daylighting systems in an effort to reduce electric lighting loads and provide a better workspace. The daylighting system, at the newly constructed 15,000 sq.ft. California State Automobile Association (CSAA) office building in Antioch, California, incorporates skylights with louvers, perforated blinds on the windows, and dimming ballasts which control T8 fluorescent fixtures. At the 7,500 sq.ft. retrofitted Verifone office building in Auburn, California, the building required a different kind of skylight to provide daylighting. Die tomore » the 10 foot attic space on the single-story building, a tubular-type of skylight was installed. The tubular skylight incorporates a long cylinder with a reflective internal surface to direct available sunlight into the workspace through a white diffuser. In addition, T8 fluorescent fixtures were controlled by dimming ballasts and light level controls. Annual lighting energy consumption at the CSAA building was reduced by 32% with a favorable reaction from the occupants. While the occupant response to the lighting at Verifone was generally good, thee were some problems in calibrating the lighting controls, thereby reducing energy savings.« less
Skylight energy performance and design optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arasteh, D.; Johnson, R.; Selkowitz, S.
1984-02-01
Proper skylight utilization can significantly lower energy requirements and peak electrical loads for space conditioning and lighting in commercial buildings. In this study we systematically explore the energy effects of skylight systems in a prototypical office building and examine the savings from daylighting. The DOE-2.1B energy analysis computer program with its newly incorporated daylighting algorithms was used to generate more than 2000 parametric simulations for seven US climates. The parameters varied include skylight-to-roof ratio, shading coefficient, visible transmittance, skylight well light loss, electric lighting power density, roof heat transfer coefficient, and type of electric lighting control. For specific climates wemore » identify roof/skylight characteristics that minimize total energy or peak electrical load requirements.« less
Joining the Great Plains in Space, Place, and Time: Questioning a Time Zone Boundary
ERIC Educational Resources Information Center
Kuper, Rob
2011-01-01
Standard time zone boundaries are invisible in the landscape, yet they abruptly delineate a temporal difference of one hour between two large areas located relative to one another on Earth. In most cases, standard time zone boundaries follow political ones and define areas within which daylight saving time (DST)--the seasonal advancement of…
Code of Federal Regulations, 2013 CFR
2013-07-01
... are between 8:45 a.m. and 4:45 p.m., eastern standard or daylight saving time as appropriate during...; computation of time; representation of parties. 966.6 Section 966.6 Postal Service UNITED STATES POSTAL... time; representation of parties. (a) Filing. All documents required under this part must be filed by...
Code of Federal Regulations, 2014 CFR
2014-07-01
... are between 8:45 a.m. and 4:45 p.m., eastern standard or daylight saving time as appropriate during...; computation of time; representation of parties. 966.6 Section 966.6 Postal Service UNITED STATES POSTAL... time; representation of parties. (a) Filing. All documents required under this part must be filed by...
17 CFR 230.110 - Business hours of the Commission.
Code of Federal Regulations, 2013 CFR
2013-04-01
... open each day, except Saturdays, Sundays, and Federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... Commission each day, except Saturdays, Sundays and federal holidays, from 5:30 p.m. to 10 p.m., Eastern...
17 CFR 230.110 - Business hours of the Commission.
Code of Federal Regulations, 2014 CFR
2014-04-01
... open each day, except Saturdays, Sundays, and Federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... Commission each day, except Saturdays, Sundays and federal holidays, from 5:30 p.m. to 10 p.m., Eastern...
17 CFR 232.12 - Business hours of the Commission.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., is open each day, except Saturdays, Sundays, and federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... the filing of documents pursuant to the Acts or the rules and regulations thereunder are as set forth...
17 CFR 230.110 - Business hours of the Commission.
Code of Federal Regulations, 2012 CFR
2012-04-01
... open each day, except Saturdays, Sundays, and Federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... Commission each day, except Saturdays, Sundays and federal holidays, from 5:30 p.m. to 10 p.m., Eastern...
17 CFR 230.110 - Business hours of the Commission.
Code of Federal Regulations, 2011 CFR
2011-04-01
... open each day, except Saturdays, Sundays, and Federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... Commission each day, except Saturdays, Sundays and federal holidays, from 5:30 p.m. to 10 p.m., Eastern...
17 CFR 232.12 - Business hours of the Commission.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., is open each day, except Saturdays, Sundays, and federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... the filing of documents pursuant to the Acts or the rules and regulations thereunder are as set forth...
Sleep Time: Media Hype vs. Diary Data
ERIC Educational Resources Information Center
Michelson, William
2011-01-01
Sleep duration has figured into claims of two trends promoted recently as dysfunctional in the mass media. One is the observation that the population at large is sleeping less than before. The second is that the annual change from Standard Time to Daylight Savings (or summer) Time causes adverse effects, largely through the loss of an hour's…
Impact of daylight saving time on road traffic collision risk: a systematic review
Carey, Rachel N; Sarma, Kiran M
2017-01-01
Background Bills have been put forward in the UK and Republic of Ireland proposing a move to Central European Time (CET). Proponents argue that such a change will have benefits for road safety, with daylight being shifted from the morning, when collision risk is lower, to the evening, when risk is higher. Studies examining the impact of daylight saving time (DST) on road traffic collision risk can help inform the debate on the potential road safety benefits of a move to CET. The objective of this systematic review was to examine the impact of DST on collision risk. Methods Major electronic databases were searched, with no restrictions as to date of publication (the last search was performed in January 2017). Access to unpublished reports was requested through an international expert group. Studies that provided a quantitative analysis of the effect of DST on road safety-related outcomes were included. The primary outcomes of interest were road traffic collisions, injuries and fatalities. Findings Twenty-four studies met the inclusion criteria. Seventeen examined the short-term impact of transitions around DST and 12 examined long-term effects. Findings from the short-term studies were inconsistent. The long-term findings suggested a positive effect of DST. However, this cannot be attributed solely to DST, as a range of road collision risk factors vary over time. Interpretation The evidence from this review cannot support or refute the assertion that a permanent shift in light from morning to evening will have a road safety benefit. PMID:28674131
Code of Federal Regulations, 2010 CFR
2010-07-01
... business hours are between 8:15 a.m. and 4:45 p.m., eastern standard or daylight saving time as appropriate...; computation of time; representation of parties. 966.6 Section 966.6 Postal Service UNITED STATES POSTAL... time; representation of parties. (a) Filing. All documents required under this part must be filed by...
Adaptive chromogenic materials and devices
NASA Astrophysics Data System (ADS)
Sixou, Pierre; Guillard, H.; Labonne, L.; Gandolfo, V.
2003-03-01
Electrically controllable glasses can be used to control daylight and solar energy in buildings and in automotives in order to improve quality of life and to save energy spent on lighting, cooling and heating. The paper discusses the case of switchable glazings using liquid crystal/polymer micro-composites. A comparison with other technologies (like inorganic electrochromics, thermotropic gels and dispersed particles) is drawn.
Code of Federal Regulations, 2011 CFR
2011-07-01
... business hours are between 8:15 a.m. and 4:45 p.m., eastern standard or daylight saving time as appropriate...; computation of time; representation of parties. 966.6 Section 966.6 Postal Service UNITED STATES POSTAL... time; representation of parties. (a) Filing. All documents required under this part must be filed by...
Code of Federal Regulations, 2012 CFR
2012-07-01
... business hours are between 8:15 a.m. and 4:45 p.m., eastern standard or daylight saving time as appropriate...; computation of time; representation of parties. 966.6 Section 966.6 Postal Service UNITED STATES POSTAL... time; representation of parties. (a) Filing. All documents required under this part must be filed by...
Aftermath of World Trade Center Attack
NASA Technical Reports Server (NTRS)
2002-01-01
This true-color image was taken by the Enhanced Thematic Mapper Plus (ETM+) aboard the Landsat 7 satellite on September 12, 2001, at roughly 11:30 a.m. Eastern Daylight Savings Time. Visit the NASA home page for photos from the space station and MODIS, and GlobalSecurity.org for images from other satellites. Image courtesy USGS Landsat 7 team, at the EROS Data Center.
Accident rates and the impact of daylight saving time transitions.
Robb, David; Barnes, Thomas
2018-02-01
One-third of nations have adopted some form of Daylight Saving Time (DST). Associated costs and benefits include impacts on accident rates. Using data from 12.6 million accident claims in New Zealand during 2005-2016, we model accident rates as a function of various date-based predictors including days before/after the start and end of DST, holidays, day of week, and month of year. This is the first study to consider multiple accident categories (Road, Work, Falls and Home & Community), and the first in the southern hemisphere. The start of DST is associated with significantly higher rates of road accidents (first day +16% and second day +12%). Evidence that accident rates for Falls and Home & Community decline (increase) prior to the start (end) of DST suggest potential behavioural adaption from anticipating the change. While Work accidents show limited impact from DST changes, they exhibit a significant decline over the course of the week (Friday 13% lower than Monday), whereas Road accidents exhibit a significant increase (Friday 19% higher than Monday). Our results have implications for both DST implementation and policy. Copyright © 2017 Elsevier Ltd. All rights reserved.
Trampoline-associated injuries are more common in children in spring.
Yule, Michael S; Krishna, Sanjeev; Rahiri, Jamie-Lee; Hill, Andrew G
2016-06-10
Trampoline use is a popular pastime amongst children in New Zealand, and has many advantages for child development. However, recent reports claim that trampoline-associated injuries are still highly prevalent. In order to help prevent these injuries in the future, this study aims to provide more up-to-date epidemiological information in children, with emphasis on the time of year that injuries most commonly occur. A retrospective review was carried out utilising a prospective maintained trauma database. The database was searched electronically for injuries involving trampolines in children aged 0-15 years. Patient demographics and information regarding month of injury, injury type and management were extracted. There were 344 admissions to hospital for trampoline-related injuries between June 2000 and January 2015. Injuries were uncommon in winter, but rose in spring and summer. Fracture of the radius and/or ulna was the most common injury (34.0%), followed by humeral fracture (32.0%). The peak incidence of trampoline-related injuries occurred around the beginning of spring daylight savings time each year. This could therefore prove an opportune time to remind children and parents about trampoline safety at the same time as daylight savings reminders.
Building integrated semi-transparent photovoltaics: energy and daylighting performance
NASA Astrophysics Data System (ADS)
Kapsis, Konstantinos; Athienitis, Andreas K.
2011-08-01
This paper focuses on modeling and evaluation of semi-transparent photovoltaic technologies integrated into a coolingdominated office building façade by employing the concept of three-section façade. An energy simulation model is developed, using building simulation software, to investigate the effect of semi-transparent photovoltaic transmittance on the energy performance of an office in a typical office building in Montreal. The analysis is performed for five major façade orientations and two façade configurations. Using semi-transparent photovoltaic integrated into the office façade, electricity savings of up to 53.1% can be achieved compared to a typical office equipped with double glazing with Argon filling and a low emissivity coating, and lighting controlled based on occupancy and daylight levels.e.c
Efficiency in energy production and consumption
NASA Astrophysics Data System (ADS)
Kellogg, Ryan Mayer
This dissertation deals with economic efficiency in the energy industry and consists of three parts. The first examines how joint experience between pairs of firms working together in oil and gas drilling improves productivity. Part two asks whether oil producers time their drilling optimally by taking real options effects into consideration. Finally, I investigate the efficiency with which energy is consumed, asking whether extending Daylight Saving Time (DST) reduces electricity use. The chapter "Learning by Drilling: Inter-Firm Learning and Relationship Persistence in the Texas Oilpatch" examines how oil production companies and the drilling rigs they hire improve drilling productivity by learning through joint experience. I find that the joint productivity of a lead firm and its drilling contractor is enhanced significantly as they accumulate experience working together. Moreover, this result is robust to other relationship specificities and standard firm-specific learning-by-doing effects. The second chapter, "Drill Now or Drill Later: The Effect of Expected Volatility on Investment," investigates the extent to which firms' drilling behavior accords with a key prescription of real options theory: irreversible investments such as drilling should be deferred when the expected volatility of the investments' payoffs increases. I combine detailed data on oil drilling with expectations of future oil price volatility that I derive from the NYMEX futures options market. Conditioning on expected price levels, I find that oil production companies significantly reduce the number of wells they drill when expected price volatility is high. I conclude with "Daylight Time and Energy: Evidence from an Australian Experiment," co-authored with Hendrik Wolff. This chapter assesses DST's impact on electricity demand using a quasi-experiment in which parts of Australia extended DST in 2000 to facilitate the Sydney Olympics. We show that the extension did not reduce overall electricity consumption, but did cause a substantial intra-day shift in demand consistent with activity patterns that are tied to the clock rather than sunrise and sunset.
Hernández-Andrés, J; Lee, R L; Romero, J
1999-09-20
Natural outdoor illumination daily undergoes large changes in its correlated color temperature (CCT), yet existing equations for calculating CCT from chromaticity coordinates span only part of this range. To improve both the gamut and accuracy of these CCT calculations, we use chromaticities calculated from our measurements of nearly 7000 daylight and skylight spectra to test an equation that accurately maps CIE 1931 chromaticities x and y into CCT. We extend the work of McCamy [Color Res. Appl. 12, 285-287 (1992)] by using a chromaticity epicenter for CCT and the inverse slope of the line that connects it to x and y. With two epicenters for different CCT ranges, our simple equation is accurate across wide chromaticity and CCT ranges (3000-10(6) K) spanned by daylight and skylight.
Impact of daylight saving time on road traffic collision risk: a systematic review.
Carey, Rachel N; Sarma, Kiran M
2017-07-02
Bills have been put forward in the UK and Republic of Ireland proposing a move to Central European Time (CET). Proponents argue that such a change will have benefits for road safety, with daylight being shifted from the morning, when collision risk is lower, to the evening, when risk is higher. Studies examining the impact of daylight saving time (DST) on road traffic collision risk can help inform the debate on the potential road safety benefits of a move to CET. The objective of this systematic review was to examine the impact of DST on collision risk. Major electronic databases were searched, with no restrictions as to date of publication (the last search was performed in January 2017). Access to unpublished reports was requested through an international expert group. Studies that provided a quantitative analysis of the effect of DST on road safety-related outcomes were included. The primary outcomes of interest were road traffic collisions, injuries and fatalities. Twenty-four studies met the inclusion criteria. Seventeen examined the short-term impact of transitions around DST and 12 examined long-term effects. Findings from the short-term studies were inconsistent. The long-term findings suggested a positive effect of DST. However, this cannot be attributed solely to DST, as a range of road collision risk factors vary over time. The evidence from this review cannot support or refute the assertion that a permanent shift in light from morning to evening will have a road safety benefit. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Minimizing lighting power density in office rooms equipped with Anidolic Daylighting Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linhart, Friedrich; Scartezzini, Jean-Louis
2010-04-15
Electric lighting is responsible for up to one third of an office building's electricity needs. Making daylight more available in office buildings can not only contribute to significant energy savings but also enhance the occupants' performance and wellbeing. Anidolic Daylighting Systems (ADS) are one type of very effective facade-integrated daylighting systems. All south-facing office rooms within the LESO solar experimental building in Lausanne (Switzerland) are equipped with a given type of ADS. A recent study has shown that these offices' occupants are highly satisfied with their lighting environment. The most energy-efficient south-facing offices have a lighting power density of lessmore » than 5W/m{sup 2}. The lighting situation within these ''best practice''-offices has been assessed using the lighting simulation software RELUX Vision. Because this lighting situation is very much appreciated by the occupants, it was used as a starting point for developing even more energy-efficient office lighting designs. Two new lighting designs, leading to lighting power densities of 3.9W/m{sup 2} and 3W/m{sup 2}, respectively, have been suggested and simulated with RELUX Vision. Simulation results have shown that the expected performances of these new systems are comparable to that of the current lighting installation within the ''best practice''-offices or even better. These simulation results have been confirmed during experiments on 20 human subjects in a test office room recently set up within the LESO building. This article gives engineers, architects and light planers valuable information and ideas on how to design energy-efficient and comfortable electric lighting systems in office rooms with abundant access to daylight. (author)« less
17 CFR 260.0-5 - Business hours of the Commission.
Code of Federal Regulations, 2011 CFR
2011-04-01
...., Washington, DC 20549, is open each day, except Saturdays, Sundays and federal holidays, from 9 a.m. to 5:30 p... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time.... 18, 1993, as amended at 65 FR 24802, Apr. 27, 2000; 68 FR 25800, May 13, 2003; 73 FR 32228, June 5...
17 CFR 260.0-5 - Business hours of the Commission.
Code of Federal Regulations, 2012 CFR
2012-04-01
...., Washington, DC 20549, is open each day, except Saturdays, Sundays and federal holidays, from 9 a.m. to 5:30 p... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time.... 18, 1993, as amended at 65 FR 24802, Apr. 27, 2000; 68 FR 25800, May 13, 2003; 73 FR 32228, June 5...
17 CFR 260.0-5 - Business hours of the Commission.
Code of Federal Regulations, 2014 CFR
2014-04-01
...., Washington, DC 20549, is open each day, except Saturdays, Sundays and federal holidays, from 9 a.m. to 5:30 p... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time.... 18, 1993, as amended at 65 FR 24802, Apr. 27, 2000; 68 FR 25800, May 13, 2003; 73 FR 32228, June 5...
17 CFR 260.0-5 - Business hours of the Commission.
Code of Federal Regulations, 2013 CFR
2013-04-01
...., Washington, DC 20549, is open each day, except Saturdays, Sundays and federal holidays, from 9 a.m. to 5:30 p... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time.... 18, 1993, as amended at 65 FR 24802, Apr. 27, 2000; 68 FR 25800, May 13, 2003; 73 FR 32228, June 5...
The impact of translucent fabric shades and control strategies on energy savings and visual quality
NASA Astrophysics Data System (ADS)
Wankanapon, Pimonmart
Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric shade colors. The results clearly show the benefit of automatic shade control strategies with integrated lighting control over a condition when shades are closed all day. The main contributor to the total energy savings is from lighting energy savings, followed by cooling energy savings. Shades provide greater benefit in a hot climate and in a moderate climate than in a cold climate. Different control strategies provide savings in the range of 7-35% for annual total space energy with higher savings with light colored shades. Control strategies of shades should be selected and optimized based on climate, orientation, window area, and window/shade properties. High performance glazings, when equipped with shades, show lower energy savings when compared to standard glazings. High transmittance/reflectance shades, such as white shades, perform better than dark shades in most of the cases due to higher lighting energy savings obtained with the automatic electric lighting control and the resulting cooling energy savings from rejection of some solar energy and a reduction in the heat from lights. A South orientation showed the least benefit of automatic control of shades when compare to other orientations due to the large fraction of time shades are required to provide visual comfort. Under automatic shade control, energy savings are higher the more often the shades can be raised. The different automatic control strategies present tradeoffs between energy savings and comfort. With regard to visual quality, daylight quality assessments on view, glare, luminance ratios, and UDI can be used to assess shade control strategies. Automatic shade control can increase the number of view hours while controlling sunlight penetration. With automatic shade control, more daylight hours can be provided within the beneficial range of 100-2000 lux compared to shades that are closed all day. For a person facing the window, discomfort glare is likely to increase the more often the shades are raised. Keeping the shades down ensures an acceptable glare condition, but limits energy savings. Luminance ratios are another metric that can be used to assess shade performance. With white shades, the luminance ratios between the task and proximate surfaces are improved. Dark shades help improve the luminance ratios between the task and distant surfaces. When the shades are left open, even with no direct sunlight in the space, task to window luminance ratios will often exceed 1:10.
Highlighting High Performance: Michael E. Capuano Early Childhood Center; Somerville, Massachusetts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2006-03-01
This brochure describes the key high-performance building features of the Michael E. Capuano Early Childhood Center. The brochure was paid for by the Massachusetts Technology Collaborative as part of their Green Schools Initiative. High-performance features described are daylighting and energy-efficient lighting, indoor air quality, solar and wind energy, building envelope, heating and cooling systems, water conservation, and acoustics. Energy cost savings are also discussed.
Daylight savings time and myocardial infarction.
Sandhu, Amneet; Seth, Milan; Gurm, Hitinder S
2014-01-01
Prior research has shown a transient increase in the incidence of acute myocardial infarction (AMI) after daylight savings time (DST) in the spring as well as a decrease in AMI after returning to standard time in the fall. These findings have not been verified in a broader population and if extant, may have significant public health and policy implications. We assessed changes in admissions for AMI undergoing percutaneous coronary intervention (PCI) in the Blue Cross Blue Shield of Michigan Cardiovascular Consortium (BMC2) database for the weeks following the four spring and three fall DST changes between March 2010 and September 2013. A negative binomial regression model was used to adjust for trend and seasonal variation. There was no difference in the total weekly number of PCIs performed for AMI for either the fall or spring time changes in the time period analysed. After adjustment for trend and seasonal effects, the Monday following spring time changes was associated with a 24% increase in daily AMI counts (p=0.011), and the Tuesday following fall changes was conversely associated with a 21% reduction (p=0.044). No other weekdays in the weeks following DST changes demonstrated significant associations. In the week following the seasonal time change, DST impacts the timing of presentations for AMI but does not influence the overall incidence of this disease.
Angular selective window systems: Assessment of technical potential for energy savings
Fernandes, Luis L.; Lee, Eleanor S.; McNeil, Andrew; ...
2014-10-16
Static angular selective shading systems block direct sunlight and admit daylight within a specific range of incident solar angles. The objective of this study is to quantify their potential to reduce energy use and peak demand in commercial buildings using state-of-the art whole-building computer simulation software that allows accurate modeling of the behavior of optically-complex fenestration systems such as angular selective systems. Three commercial systems were evaluated: a micro-perforated screen, a tubular shading structure, and an expanded metal mesh. This evaluation was performed through computer simulation for multiple climates (Chicago, Illinois and Houston, Texas), window-to-wall ratios (0.15-0.60), building codes (ASHRAEmore » 90.1-2004 and 2010) and lighting control configurations (with and without). The modeling of the optical complexity of the systems took advantage of the development of state-of-the-art versions of the EnergyPlus, Radiance and Window simulation tools. Results show significant reductions in perimeter zone energy use; the best system reached 28% and 47% savings, respectively without and with daylighting controls (ASHRAE 90.1-2004, south facade, Chicago,WWR=0.45). As a result, angular selectivity and thermal conductance of the angle-selective layer, as well as spectral selectivity of low-emissivity coatings, were identified as factors with significant impact on performance.« less
An Adaptive Intelligent Integrated Lighting Control Approach for High-Performance Office Buildings
NASA Astrophysics Data System (ADS)
Karizi, Nasim
An acute and crucial societal problem is the energy consumed in existing commercial buildings. There are 1.5 million commercial buildings in the U.S. with only about 3% being built each year. Hence, existing buildings need to be properly operated and maintained for several decades. Application of integrated centralized control systems in buildings could lead to more than 50% energy savings. This research work demonstrates an innovative adaptive integrated lighting control approach which could achieve significant energy savings and increase indoor comfort in high performance office buildings. In the first phase of the study, a predictive algorithm was developed and validated through experiments in an actual test room. The objective was to regulate daylight on a specified work plane by controlling the blind slat angles. Furthermore, a sensor-based integrated adaptive lighting controller was designed in Simulink which included an innovative sensor optimization approach based on genetic algorithm to minimize the number of sensors and efficiently place them in the office. The controller was designed based on simple integral controllers. The objective of developed control algorithm was to improve the illuminance situation in the office through controlling the daylight and electrical lighting. To evaluate the performance of the system, the controller was applied on experimental office model in Lee et al.'s research study in 1998. The result of the developed control approach indicate a significantly improvement in lighting situation and 1-23% and 50-78% monthly electrical energy savings in the office model, compared to two static strategies when the blinds were left open and closed during the whole year respectively.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-09
...-2504B currently reads ``0600 to 2400 PST, daily'' and the time of designation for R-2530 currently reads...-2400 local time, daily, during both standard time and daylight saving time periods and for R-2530 is... time of designation is amended to read ``0600 to 2400 local time, daily'' for R-2504A and R-2504B and...
75 FR 14131 - Broadband Technology Opportunities Program
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-24
... DEPARTMENT OF COMMERCE National Telecommunications and Information Administration [Docket Number: 0907141137-0154-09] RIN 0660-ZA28 Broadband Technology Opportunities Program AGENCY: National... under the Broadband Technology Opportunities Program (BTOP) is extended until 10 p.m. Eastern Daylight...
Multiobjective generalized extremal optimization algorithm for simulation of daylight illuminants
NASA Astrophysics Data System (ADS)
Kumar, Srividya Ravindra; Kurian, Ciji Pearl; Gomes-Borges, Marcos Eduardo
2017-10-01
Daylight illuminants are widely used as references for color quality testing and optical vision testing applications. Presently used daylight simulators make use of fluorescent bulbs that are not tunable and occupy more space inside the quality testing chambers. By designing a spectrally tunable LED light source with an optimal number of LEDs, cost, space, and energy can be saved. This paper describes an application of the generalized extremal optimization (GEO) algorithm for selection of the appropriate quantity and quality of LEDs that compose the light source. The multiobjective approach of this algorithm tries to get the best spectral simulation with minimum fitness error toward the target spectrum, correlated color temperature (CCT) the same as the target spectrum, high color rendering index (CRI), and luminous flux as required for testing applications. GEO is a global search algorithm based on phenomena of natural evolution and is especially designed to be used in complex optimization problems. Several simulations have been conducted to validate the performance of the algorithm. The methodology applied to model the LEDs, together with the theoretical basis for CCT and CRI calculation, is presented in this paper. A comparative result analysis of M-GEO evolutionary algorithm with the Levenberg-Marquardt conventional deterministic algorithm is also presented.
Daylight savings time and myocardial infarction
Sandhu, Amneet; Seth, Milan; Gurm, Hitinder S
2014-01-01
Background Prior research has shown a transient increase in the incidence of acute myocardial infarction (AMI) after daylight savings time (DST) in the spring as well as a decrease in AMI after returning to standard time in the fall. These findings have not been verified in a broader population and if extant, may have significant public health and policy implications. Methods We assessed changes in admissions for AMI undergoing percutaneous coronary intervention (PCI) in the Blue Cross Blue Shield of Michigan Cardiovascular Consortium (BMC2) database for the weeks following the four spring and three fall DST changes between March 2010 and September 2013. A negative binomial regression model was used to adjust for trend and seasonal variation. Results There was no difference in the total weekly number of PCIs performed for AMI for either the fall or spring time changes in the time period analysed. After adjustment for trend and seasonal effects, the Monday following spring time changes was associated with a 24% increase in daily AMI counts (p=0.011), and the Tuesday following fall changes was conversely associated with a 21% reduction (p=0.044). No other weekdays in the weeks following DST changes demonstrated significant associations. Conclusions In the week following the seasonal time change, DST impacts the timing of presentations for AMI but does not influence the overall incidence of this disease. PMID:25332784
The energy performance of prototype holographic glazings
NASA Astrophysics Data System (ADS)
Papamichael, K.; Beltran, L.; Furler, R.; Lee, E. S.; Selkowitz, S.; Rubin, M.
1993-02-01
We report on the simulation of the energy performance of prototype holographic glazings in commercial office buildings in a California climate. These prototype glazings, installed above conventional side windows, are designed to diffract the transmitted solar radiation and reflect it off the ceiling, providing adequate daylight illumination for typical office tasks up to 10m from the window. In this study, we experimentally determined a comprehensive set of solar-optical properties and characterized the contribution of the prototype holographic glazings to workplane illuminance in a scale model of a typical office space. We then used the scale model measurements to simulate the energy performance of the holographic glazings over the course of an entire year for four window orientations (North, East, South and West) for the inland Los Angeles climate, using the DOE-2.lD building energy analysis computer program. The results of our experimental analyses indicate that these prototype holographic glazings diffract only a small fraction of the incident light. The results of this study indicate that these prototype holographic glazings will not save energy in commercial office buildings. Their performance is very similar to that of clear glass, which, through side windows, cannot efficiently illuminate more than a 4-6 m depth of a building's perimeter, because the cooling penalties due to solar heat gain are greater than the electric lighting savings due to daylighting.
Warrant, Eric J; Locket, N Adam
2004-08-01
The deep sea is the largest habitat on earth. Its three great faunal environments--the twilight mesopelagic zone, the dark bathypelagic zone and the vast flat expanses of the benthic habitat--are home to a rich fauna of vertebrates and invertebrates. In the mesopelagic zone (150-1000 m), the down-welling daylight creates an extended scene that becomes increasingly dimmer and bluer with depth. The available daylight also originates increasingly from vertically above, and bioluminescent point-source flashes, well contrasted against the dim background daylight, become increasingly visible. In the bathypelagic zone below 1000 m no daylight remains, and the scene becomes entirely dominated by point-like bioluminescence. This changing nature of visual scenes with depth--from extended source to point source--has had a profound effect on the designs of deep-sea eyes, both optically and neurally, a fact that until recently was not fully appreciated. Recent measurements of the sensitivity and spatial resolution of deep-sea eyes--particularly from the camera eyes of fishes and cephalopods and the compound eyes of crustaceans--reveal that ocular designs are well matched to the nature of the visual scene at any given depth. This match between eye design and visual scene is the subject of this review. The greatest variation in eye design is found in the mesopelagic zone, where dim down-welling daylight and bio-luminescent point sources may be visible simultaneously. Some mesopelagic eyes rely on spatial and temporal summation to increase sensitivity to a dim extended scene, while others sacrifice this sensitivity to localise pinpoints of bright bioluminescence. Yet other eyes have retinal regions separately specialised for each type of light. In the bathypelagic zone, eyes generally get smaller and therefore less sensitive to point sources with increasing depth. In fishes, this insensitivity, combined with surprisingly high spatial resolution, is very well adapted to the detection and localisation of point-source bioluminescence at ecologically meaningful distances. At all depths, the eyes of animals active on and over the nutrient-rich sea floor are generally larger than the eyes of pelagic species. In fishes, the retinal ganglion cells are also frequently arranged in a horizontal visual streak, an adaptation for viewing the wide flat horizon of the sea floor, and all animals living there. These and many other aspects of light and vision in the deep sea are reviewed in support of the following conclusion: it is not only the intensity of light at different depths, but also its distribution in space, which has been a major force in the evolution of deep-sea vision.
NASA Astrophysics Data System (ADS)
Markou, M. T.; Kambezidis, H. D.; Bartzokas, A.; Darula, S.; Kittler, R.
2007-12-01
In this work, daylight reference years (DRYs), based on daylight and solar radiation measurements, are designed for two European cities, Athens, Greece and Bratislava, Slovakia, by using the Danish method, the Festa-Ratto technique and the Modified Sandia National Laboratories methodology. The data basis consists of 5-minute values of global and diffuse horizontal illuminance, global and diffuse horizontal irradiance, zenith luminance and solar altitude as well as of daily values of sunshine duration for 5 years for Athens and 8 years for Bratislava. Moreover, Linke's turbidity factor, luminous turbidity factor and relative sunshine duration are calculated and utilized. Then, for each DRY, the predominant sky-luminance distributions over Athens and Bratislava are identified, by using the methodology of Kittler et al., who corresponded the main sky conditions to 15 theoretical sky standards in diagrams of the ratio of zenith luminance to diffuse horizontal illuminance against solar altitude. For both cities the three aforementioned methods do not create identical DRYs. Despite the differences, the sky types defined for each of the two places seem not to depend on the choice of DRY. The predominant sky standard, for all of them, is a cloudless, polluted sky with a broad solar corona for Athens and an overcast sky with slight brightening towards the sun as well as very clear sky with low atmospheric turbidity for Bratislava. However, the selection of the DRY, which represents best the daylight conditions, is necessary for studies in saving energy in buildings. The DRY, which is created by the Modified Sandia National Laboratories method, is chosen for most cases, while the one created by the Danish method is also useful on certain occasions.
Technical-economic feasibility of orbiting sunlight reflectors
NASA Astrophysics Data System (ADS)
Alferov, Z.; Minin, V.
1986-02-01
The use of deflectors in orbit as a means of providing artificial illumination is examined. Considerations of technical and economic feasibility are addressed. Three main areas of application are distinguished: reflecting sunlight onto the surface of the Earth; concentration of the flow of solar energy on an orbiting receiver; and retransmission of optical radiation. The advantages of the artificial Earth illumination application of the orbiting reflector scheme in terms of energy savings in lighting cities, and additional daylight time for critical periods of farming operations are discussed.
Microcomputer-controlled world time display for public area viewing
NASA Astrophysics Data System (ADS)
Yep, S.; Rashidian, M.
1982-05-01
The design, development, and implementation of a microcomputer-controlled world clock is discussed. The system, designated international Time Display System (ITDS), integrates a Geochron Calendar Map and a microcomputer-based digital display to automatically compensate for daylight savings time, leap year, and time zone differences. An in-depth technical description of the design and development of the electronic hardware, firmware, and software systems is provided. Reference material on the time zones, fabrication techniques, and electronic subsystems are also provided.
Progress Towards Highly Efficient Windows for Zero—Energy Buildings
NASA Astrophysics Data System (ADS)
Selkowitz, Stephen
2008-09-01
Energy efficient windows could save 4 quads/year, with an additional 1 quad/year gain from daylighting in commercial buildings. This corresponds to 13% of energy used by US buildings and 5% of all energy used by the US. The technical potential is thus very large and the economic potential is slowly becoming a reality. This paper describes the progress in energy efficient windows that employ low-emissivity glazing, electrochromic switchable coatings and other novel materials. Dynamic systems are being developed that use sensors and controls to modulate daylighting and shading contributions in response to occupancy, comfort and energy needs. Improving the energy performance of windows involves physics in a variety of application: optics, heat transfer, materials science and applied engineering. Technical solutions must also be compatible with national policy, codes and standards, economics, business practice and investment, real and perceived risks, comfort, health, safety, productivity, amenities, and occupant preference and values. The challenge is to optimize energy performance by understanding and reinforcing the synergetic coupling between these many issues.
Muñoz, Ricardo C
2012-06-01
Daylight saving time (DST) is a common practice in many countries, in which Official Time (OT) is abruptly shifted 1 hour with respect to solar time on two occasions every year (in fall and spring). All anthropogenic emitting processes tied to OT like job and school commuting traffic, abruptly change in this moment their timing with respect to solar time, inducing a sudden shift between emissions and the meteorological factors that control the dispersion and transport of air pollutants. Analyzing 13 years of hourly particulate matter (PM10) concentrations measured in Santiago, Chile, we demonstrate that the DST practice has observable non-trivial effects in the PM10 diurnal cycle. The clearest impact is in the morning peak of PM10 during the fall DST change, which occurs later and has on average a significant smaller magnitude in the days after the DST change as compared to the days before it. This decrease in magnitude is most remarkable because it occurs in a period of the year when overall PM10 concentrations increase due to generally worsening of the dispersion conditions. Results are shown for seven monitoring stations around the city, and for the fall and spring DST changes. They show clearly the interplay of emissions and meteorology in conditioning urban air pollution problems, highlighting the role of the morning and evening transitions of the atmospheric boundary layer in shaping the diurnal pattern of urban air pollutant concentrations.
The NIST Internet time service
NASA Astrophysics Data System (ADS)
Levine, Judah
1994-05-01
We will describe the NIST Network Time Service which provides time and frequency information over the Internet. Our first time server is located in Boulder, Colorado, a second backup server is under construction there, and we plan to install a third server on the East Coast later this year. The servers are synchronized to UTC(NIST) with an uncertainty of about 0.8 ms RMS and they will respond to time requests from any client on the Internet in several different formats including the DAYTIME, TIME and NTP protocols. The DAYTIME and TIME protocols are the easiest to use and are suitable for providing time to PC's and other small computers. In addition to UTC(NIST), the DAYTIME message provides advance notice of leap seconds and of the transitions to and from Daylight Saving Time. The Daylight Saving Time notice is based on the US transition dates of the first Sunday in April and the last one in October. The NTP is a more complex protocol that is suitable for larger machines; it is normally run as a 'daemon' process in the background and can keep the time of the client to within a few milliseconds of UTC(NIST). We will describe the operating principles of various kinds of client software ranging from a simple program that queries the server once and sets the local clock to more complex 'daemon' processes (such as NTP) that continuously correct the time of the local clock based on periodic calibrations.
Does the transition into daylight saving time really cause partial sleep deprivation?
Toth Quintilham, Manoel Carlos; Adamowicz, Taísa; Pereira, Erico Felden; Pedrazzoli, Mario; Louzada, Fernando Mazzilli
2014-01-01
To identify possible changes in the sleep patterns according to chronotype in undergraduate students during the daylight saving time (DST) transition. A total of 378 students answered the Morningness-Eveningness Questionnaire (MEQ) to determine their chronotype and kept a diary about sleep-wake schedules 1 week before and after the DST transition. Oral mucosal cell samples were collected for genetic analysis. After the DST transition, intermediate types (I-types) delayed bedtime and increased their time in bed and all groups delayed their wake-up time. All groups presented a shorter phase angle between sunset and the bedtime after the DST transition. On the other hand, only E-types showed a tendency to reduce the phase angle between sunrise and wake-up time, while I-types and M-types kept the same phase angles between sunrise and wake-up time after the DST transition. The polymorphisms in the human genes CLOCK and PER3 were not associated with individual differences in sleep patterns, nor were they associated with an adjustment to the DST transition. Under the new set of social times determined by DST, the adjustment was only partial. I-types delayed bedtime and all groups delayed their wake-up times after the beginning of DST. Consequently, the time in bed after the DST transition was not reduced; Morning (M-types) and Evening-types (E-types) kept the same time in bed and I-types showed an increase on it.
The NIST Internet time service
NASA Technical Reports Server (NTRS)
Levine, Judah
1994-01-01
We will describe the NIST Network Time Service which provides time and frequency information over the Internet. Our first time server is located in Boulder, Colorado, a second backup server is under construction there, and we plan to install a third server on the East Coast later this year. The servers are synchronized to UTC(NIST) with an uncertainty of about 0.8 ms RMS and they will respond to time requests from any client on the Internet in several different formats including the DAYTIME, TIME and NTP protocols. The DAYTIME and TIME protocols are the easiest to use and are suitable for providing time to PC's and other small computers. In addition to UTC(NIST), the DAYTIME message provides advance notice of leap seconds and of the transitions to and from Daylight Saving Time. The Daylight Saving Time notice is based on the US transition dates of the first Sunday in April and the last one in October. The NTP is a more complex protocol that is suitable for larger machines; it is normally run as a 'daemon' process in the background and can keep the time of the client to within a few milliseconds of UTC(NIST). We will describe the operating principles of various kinds of client software ranging from a simple program that queries the server once and sets the local clock to more complex 'daemon' processes (such as NTP) that continuously correct the time of the local clock based on periodic calibrations.
Daylight characterization through vision-based sensing of lighting conditions in buildings
NASA Astrophysics Data System (ADS)
di Dio, Joseph, III
A new method for describing daylight under unknown weather conditions, as captured in images of a room, is proposed. This method considers pixel brightness information to be a linear combination of diffuse and directional light components, as received by a web cam from the walls and ceiling of an occupied office. The nature of these components in each image is determined by building orientation, room geometry, neighboring structures and the position of the sun. Considering daylight in this manner also allows for an estimation of the sky conditions at a given instant to be made, and presents a means to uncover seasonal trends in the behavior of light simply by monitoring the brightness variations of points on the walls and ceiling. Significantly, this daylight characterization method also allows for an estimation of the illumination level on a target surface to be made from image data. Currently, illumination at a target surface is estimated through the use of a ceiling-mounted photosensor, as part of a lighting control system, in the hopes of achieving a suitable balance between daylight and electrical lighting in a space. Improving the ability of a sensor to estimate the illumination is of great importance to those who wish to minimize unnecessary energy consumption, as a significant percentage of all U.S. electricity is currently consumed by light fixtures. A photosensor detects light that falls on its location, which does not necessarily correspond in a fixed manner to the light level on the target areas that the photosensor is meant to monitor. Additionally, a photosensor cannot discern variations in light distribution across a room, which often occur with daylight. By considering pixel brightness information to be a linear combination of diffuse and directional light components at selected pixels in an image, information about the light reaching these pixels can be extracted from observed patterns of brightness, under different light conditions. In this manner, each pixel provides information about the light field at its corresponding point in the room, and thus each pixel can be considered to behave as if it were a remote photosensor. By using multiple pixel readings in lieu of a single photosensor reading of a given light condition, an improved assessment of the illumination level on a target surface can been achieved. It is shown that on average, the camera-based method was approximately 25% more accurate in estimating illuminance in the test room than was a simulated ceiling-mounted photosensor. It is hoped that the methodology detailed here will aid in the eventual development of a camera-based daylight characterization sensor for use in lighting control systems, so that the potential for enhanced energy savings can be realized.
Automatic target detection using binary template matching
NASA Astrophysics Data System (ADS)
Jun, Dong-San; Sun, Sun-Gu; Park, HyunWook
2005-03-01
This paper presents a new automatic target detection (ATD) algorithm to detect targets such as battle tanks and armored personal carriers in ground-to-ground scenarios. Whereas most ATD algorithms were developed for forward-looking infrared (FLIR) images, we have developed an ATD algorithm for charge-coupled device (CCD) images, which have superior quality to FLIR images in daylight. The proposed algorithm uses fast binary template matching with an adaptive binarization, which is robust to various light conditions in CCD images and saves computation time. Experimental results show that the proposed method has good detection performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This publication is one in an ongoing series of case studies for "Laboratories for the 21st Century," a joint program of the U.S. Environmental Protection Agency and the U.S. Department of Energy Federal Energy Management Program. It is intended for all those who plan, design, and construct public and private-sector laboratory buildings. This study describes how the Nidus Center, a nonprofit incubator for life sciences and plan biotechnology established by Monsanto Company, employs daylighting, an energy-efficient mechanical system featuring energy recovery, and water conservation practices, among others, to save energy and money and help conserve natural resources.
Energy-efficient building design in cold climates: Schools as a case study
NASA Astrophysics Data System (ADS)
Rangel Ruiz, Rocio
Buildings account for great amounts of greenhouse gas emissions. In terms of energy, buildings account for one third of the total amount of energy used in the country every year! Schools account for 14 percent of the energy used annually in commercial and institutional buildings. Further, schools are one of the most commonly constructed building types in Canada and spaces such as classrooms are often duplicated. This makes them preferred candidates for the research that was undertaken where energy-efficient solutions that can be transferred to different school designs were derived. Throughout the study, the Commercial Building Incentive Program (CBIP) was used as a benchmark. The objectives of the study were to demonstrate energy-efficient concepts, provide a case study to evaluate solutions, develop typological models and provide an understanding of the innovation process. The technological and societal aspects of the energy-efficient design were addressed. With respect to the technological aspects, the first step was the analysis of conventional design using a school in Calgary as a case study. The optimization of conventional design was undertaken using computer modeling to identify best practice solutions. Aspects that were included in the studies were lighting design, envelope characteristics, HVAC systems and building plant systems. The inclusion of passive design included the analysis of daylighting and natural ventilation. Computer modeling was used to assess daylighting in classrooms with unilateral and bilateral daylighting. Illuminance levels, glare and light distribution were evaluated. The study of natural ventilation was undertaken using literature review. Airflow and outdoor temperatures were the focus to identify solutions that could be incorporated into the design of classrooms. It was concluded that achieving excellence in energy efficiency in schools could be achieved using readily available technologies. Energy savings of up to 63 percent better than Canada's Model National Energy Code for Buildings (MNECB) reference case and utility cost savings of 30,000 (on a 50,000 annual cost) were achieved through conventional design optimization. Additional energy savings of three percent and utility cost savings of $7,000 were seen when passive strategies were included in the design. With respect to the societal aspects, an exploratory research study was undertaken to examine innovation. Architects and energy consultants were interviewed. All design professionals included in the study had participated in projects approved for a grant under CBIP. The purpose of the study was to identify drivers and barriers to energy efficiency. The study demonstrated that external and internal innovation pressures have a significant effect on whether or not the technology is adopted. Suggestions for reducing barriers and further promoting energy efficiency are discussed in this thesis. It is expected that the research will not only aid designers in assessing projects with regard to local priorities, but will also provide building guidelines that serve as tools for the development of the Canadian energy compliance for CO2 emissions.
NASA Astrophysics Data System (ADS)
Cárdenas, J.; Osma, G.; Caicedo, C.; Torres, A.; Sánchez, S.; Ordóñez, G.
2016-07-01
This research shows the energy analysis of the Electrical Engineering Building, located on campus of the Industrial University of Santander in Bucaramanga - Colombia. This building is a green pilot for analysing energy saving strategies such as solar pipes, green roof, daylighting, and automation, among others. Energy analysis was performed by means of DesignBuilder software from virtual model of the building. Several variables were analysed such as air temperature, relative humidity, air velocity, daylighting, and energy consumption. According to two criteria, thermal load and energy consumption, critical areas were defined. The calibration and validation process of the virtual model was done obtaining error below 5% in comparison with measured values. The simulations show that the average indoor temperature in the critical areas of the building was 27°C, whilst relative humidity reached values near to 70% per year. The most critical discomfort conditions were found in the area of the greatest concentration of people, which has an average annual temperature of 30°C. Solar pipes can increase 33% daylight levels into the areas located on the upper floors of the building. In the case of the green roofs, the simulated results show that these reduces of nearly 31% of the internal heat gains through the roof, as well as a decrease in energy consumption related to air conditioning of 5% for some areas on the fourth and fifth floor. The estimated energy consumption of the building was 69 283 kWh per year.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-29
... under USFWS's now-discontinued program, are considered non-essential experimental populations. The black... daylight hours. Additional methodological detail is available in VanBlaricom, 1993 and VanBlaricom et al..., 1987). The non-breeding distribution extends from Baja California north to Alaska for males, and...
Parametric analysis of parameters for electrical-load forecasting using artificial neural networks
NASA Astrophysics Data System (ADS)
Gerber, William J.; Gonzalez, Avelino J.; Georgiopoulos, Michael
1997-04-01
Accurate total system electrical load forecasting is a necessary part of resource management for power generation companies. The better the hourly load forecast, the more closely the power generation assets of the company can be configured to minimize the cost. Automating this process is a profitable goal and neural networks should provide an excellent means of doing the automation. However, prior to developing such a system, the optimal set of input parameters must be determined. The approach of this research was to determine what those inputs should be through a parametric study of potentially good inputs. Input parameters tested were ambient temperature, total electrical load, the day of the week, humidity, dew point temperature, daylight savings time, length of daylight, season, forecast light index and forecast wind velocity. For testing, a limited number of temperatures and total electrical loads were used as a basic reference input parameter set. Most parameters showed some forecasting improvement when added individually to the basic parameter set. Significantly, major improvements were exhibited with the day of the week, dew point temperatures, additional temperatures and loads, forecast light index and forecast wind velocity.
Transition into and out of daylight saving time and spontaneous delivery: a population-based study
László, Krisztina D; Cnattingius, Sven; Janszky, Imre
2016-01-01
Objective To investigate whether the circadian rhythm disruption following the transition into and out of daylight saving time (DST) is associated with an increased risk of spontaneous delivery. Design We compared the number of spontaneous deliveries in the Swedish Medical Birth Register during the week after the change to and the week after the change from DST (exposure periods) with the average number of spontaneous deliveries in the control period, defined as the week before and the week after each exposure period. Setting Sweden, 1993–2006. Primary and secondary outcome measures The primary outcomes were the weekly and the daily number of spontaneous deliveries in the exposure and the control periods. In secondary analyses we also compared the mean length of pregnancy of the women with spontaneous deliveries in the exposure and control periods. Results The number of deliveries during the week after the transition into or out of DST was similar to that in the comparison period (18 519 observed vs 18 434 expected in case of the spring shift and 19 073 observed vs 19 122 expected in case of the autumn shift); the corresponding incidence ratio and 95% CIs were 1.005 (0.990 to 1.019) and 0.997 (0.983 to 1.012), respectively. There were no differences in the length of gestation of the deliveries in the exposure and the control periods. Conclusions Our results do not support the hypothesis that a minor circadian rhythm disruption is associated with an increased short-term risk of spontaneous delivery. PMID:27630067
Fatal accidents following changes in daylight savings time: the American experience.
Varughese; Allen
2001-01-01
Objective: This study examines specific hypotheses that both sleep loss and behavioral changes occurring with the time shifts for Daylight Savings Time (DST) significantly effect the number of fatal traffic accidents in the United States of America.Background: It has been reported that there is a significant increase in the number of automobile accidents in the spring shift to DST due to the loss of 1 h of sleep. But the extra hour gained at night with the shift from DST in the fall has been variably reported to be associated with increases and decreases in the number of automobile accidents which may reflect either behavioral anticipation with an extended late night prior to the change or the benefit of extra sleep after the change.Methods: Data from 21 years of United States' fatal automobile accidents were gathered. The mean number of accidents on the days at the time of the shifts (Saturday, Sunday and Monday) was compared to the average of the corresponding mean number of accidents on the matching day of the weeks preceding and following the shift. This was repeated for each DST shift. The number of accidents for a particular shift was also correlated with the year of the accidents.Results: There was a significant increase in accidents for the Monday immediately following the spring shift to DST (t=1.92, P=0.034). There was also a significant increase in number of accidents on the Sunday of the fall shift from DST (P<0.002). No significant changes were observed for the other days. A significant negative correlation with the year was found between the number of accidents on the Saturdays and Sundays but not Mondays.Conclusions: The sleep deprivation on the Monday following shift to DST in the spring results in a small increase in fatal accidents. The behavioral adaptation anticipating the longer day on Sunday of the shift from DST in the fall leads to an increased number of accidents suggesting an increase in late night (early Sunday morning) driving when traffic related fatalities are high possibly related to alcohol consumption and driving while sleepy. Public health educators should probably consider issuing warnings both about the effects of sleep loss in the spring shift and possible behaviors such as staying out later, particularly when consuming alcohol in the fall shift. Sleep clinicians should be aware that health consequences from forced changes in the circadian patterns resulting from DST come not only from physiological adjustments but also from behavioral responses to forced circadian changes.
Options for reducing carbon dioxide emissions
NASA Astrophysics Data System (ADS)
Rosenfeld, Arthur H.; Price, Lynn
1992-03-01
Improvements in energy efficiency can significantly reduce the annual growth in greenhouse gas emissions. Such improvements occur when energy intensity is reduced; no reduction in energy services is required. Using the concept of ``cost of conserved energy'' to develop conservation supply curves similar to resource supply curves, researchers consistently find that electricity and natural gas savings of nearly 50% of current consumption are possible for U.S. buildings. Such reductions in energy consumption directly reduce emissions of greenhouse gases. To capture these savings, we must continue to develop energy-efficient technologies and strategies. This paper describes three recent energy-efficient technologies that benefitted from energy conservation research and development (R&D) funding: high-frequency ballasts, compact fluorescent lamps, and low-emissivity windows. Other advanced technologies and strategies of spectrally selective windows, superwindows, electrochromic windows, advanced insulation, low-flow showerheads, improved recessed lamp fixtures, whitening surfaces and planting urban trees, daylighting, and thermal energy storage are also discussed.
Energy Savings by Treating Buildings as Systems
NASA Astrophysics Data System (ADS)
Harvey, L. D. Danny
2008-09-01
This paper reviews the opportunities for dramatically reducing energy use in buildings by treating buildings as systems, rather than focusing on device efficiencies. Systems-level considerations are relevant for the operation of heat pumps (where the temperatures at which heat or coldness are distributed are particularly important); the joint or separate provision of heating, cooling, and ventilation; the joint or separate removal of sensible heat and moisture; and in the operation of fluid systems having pumps. Passive heating, cooling, and ventilation, as well as daylighting (use of sunlight for lighting purposes) also require consideration of buildings as systems. In order to achieve the significant (50-75%) energy savings that are possible through a systems approach, the design process itself has to involve a high degree of integration between the architect and various engineering disciplines (structural, mechanical, electrical), and requires the systematic examination and adjustment of alternative designs using computer simulation models.
75 FR 55739 - Cybersecurity, Innovation and the Internet Economy
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-14
...The Department of Commerce's Internet Policy Task Force announces that the closing deadline for submission of comments responsive to the July 28, 2010 notice of inquiry on the nexus between cybersecurity challenges in the commercial sector and innovation in the Internet economy has been extended until 5 p.m. Eastern Daylight Time (EDT) on September 20, 2010.
NASA Technical Reports Server (NTRS)
Klassen, Steve; Bugbee, Bruce
2005-01-01
Accurate shortwave radiation data is critical to evapotranspiration (ET) models used for developing irrigation schedules to optimize crop production while saving water, minimizing fertilizer, herbicide, and pesticide applications, reducing soil erosion, and protecting surface and ground water quality. Low cost silicon cell pyranometers have proven to be sufficiently accurate and robust for widespread use in agricultural applications under unobstructed daylight conditions. More expensive thermopile pyranometers are required for use as calibration standards and measurements under light with unique spectral properties (electric lights, under vegetation, in greenhouses and growth chambers). Routine cleaning, leveling, and annual calibration checks will help to ensure the integrity of long-term data.
ERIC Educational Resources Information Center
Heschong, Lisa
This study examines the effect of daylighting on human performance, focusing on skylighting as a way to isolate daylight as an illumination source, and separate illumination effects from other qualities associated with daylighting from windows. It establishes a statistical connection between daylighting and student performance and between…
Effect of dividing daylight in symmetric prismatic daylight collector
NASA Astrophysics Data System (ADS)
Yeh, Shih-Chuan; Lu, Ju-Lin; Cheng, Yu-Chin
2017-04-01
This paper presented a symmetric prismatic daylight collector to collect daylight for the natural light illumination system. We analyzed the characteristics of the emerging light when the parallel light beam illuminate on the horizontally placed symmetric prismatic daylight collector. The ratio of the relative intensities of collected daylight that emerging from each surface of the daylight collector shown that the ratio is varied with the incident angle during a day. The simulation of the emerging light of the daylight collector shown that the ratio of emerging light is varied with the tilted angle when sunshine illuminated on a symmetric prismatic daylight collector which was not placed horizontally. The integration of normalized intensity is also varied with the tilted angle. The symmetric prismatic daylight collector with the benefits of reducing glare and dividing intensity of incident daylight, it is applicable to using in the natural light illumination system and hybrid system for improving the efficiency of utilizing of solar energy.
Energy-saving approaches to solid state street lighting
NASA Astrophysics Data System (ADS)
Vitta, Pranciškus; Stanikūnas, Rytis; Tuzikas, Arūnas; Reklaitis, Ignas; Stonkus, Andrius; Petrulis, Andrius; Vaitkevičius, Henrikas; Žukauskas, Artūras
2011-10-01
We consider the energy-saving potential of solid-state street lighting due to improved visual performance, weather sensitive luminance control and tracking of pedestrians and vehicles. A psychophysical experiment on the measurement of reaction time with a decision making task was performed under mesopic levels of illumination provided by a highpressure sodium (HPS) lamp and different solid-state light sources, such as daylight and warm-white phosphor converted light-emitting diodes (LEDs) and red-green-blue LED clusters. The results of the experiment imply that photopic luminances of road surface provided by solid-state light sources with an optimized spectral power distribution might be up to twice as low as those provided by the HPS lamp. Dynamical correction of road luminance against road surface conditions typical of Lithuanian climate was estimated to save about 20% of energy in comparison with constant-level illumination. The estimated energy savings due to the tracking of pedestrians and vehicles amount at least 25% with the cumulative effect of intelligent control of at least 40%. A solid-state street lighting system with intelligent control was demonstrated using a 300 m long test ground consisting of 10 solid-state street luminaires, a meteorological station and microwave motion sensor network operated via power line communication.
Transition into and out of daylight saving time and spontaneous delivery: a population-based study.
László, Krisztina D; Cnattingius, Sven; Janszky, Imre
2016-09-14
To investigate whether the circadian rhythm disruption following the transition into and out of daylight saving time (DST) is associated with an increased risk of spontaneous delivery. We compared the number of spontaneous deliveries in the Swedish Medical Birth Register during the week after the change to and the week after the change from DST (exposure periods) with the average number of spontaneous deliveries in the control period, defined as the week before and the week after each exposure period. Sweden, 1993-2006. The primary outcomes were the weekly and the daily number of spontaneous deliveries in the exposure and the control periods. In secondary analyses we also compared the mean length of pregnancy of the women with spontaneous deliveries in the exposure and control periods. The number of deliveries during the week after the transition into or out of DST was similar to that in the comparison period (18 519 observed vs 18 434 expected in case of the spring shift and 19 073 observed vs 19 122 expected in case of the autumn shift); the corresponding incidence ratio and 95% CIs were 1.005 (0.990 to 1.019) and 0.997 (0.983 to 1.012), respectively. There were no differences in the length of gestation of the deliveries in the exposure and the control periods. Our results do not support the hypothesis that a minor circadian rhythm disruption is associated with an increased short-term risk of spontaneous delivery. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Incidence of myocardial infarction with shifts to and from daylight savings time.
Jiddou, Monica R; Pica, Mark; Boura, Judy; Qu, Lihua; Franklin, Barry A
2013-03-01
Modulators of normal bodily functions such as the duration and quality of sleep might transiently influence cardiovascular risk. The transition to daylight savings time (DST) has been associated with a short-term increased incidence ratio (IR) of acute myocardial infarction (AMI). The present retrospective study examined the IR of AMIs that presented to our hospitals the week after DST and after the autumn switch to standard time, October 2006 to April 2012, with specific reference to the AMI type. Our study population (n = 935 patients; 59% men, 41% women) was obtained from the electronic medical records of the Royal Oak and Troy campuses of the Beaumont Hospitals in Michigan. Overall, the frequency of AMI was similar in the spring and autumn, 463 (49.5%) and 472 (50.5%), respectively. The IR for the first week after the spring shift was 1.17 (95% confidence interval 1.00 to 1.36). After the transition from DST in the autumn, the IR for the same period was lower, but not significantly different, 0.99 (95% confidence interval 0.85 to 1.16). Nevertheless, the greatest increase in AMI occurred on the first day (Sunday) after the spring shift to DST (1.71, 95% confidence interval 1.09 to 2.02; p <0.05). Also, a significantly greater incidence was found of non-ST-segment myocardial infarction after the transition to DST in the study group compared with that in the control group (p = 0.022). In conclusion, these data suggest that shifts to and from DST might transiently affect the incidence and type of acute cardiac events, albeit modestly. Copyright © 2013 Elsevier Inc. All rights reserved.
Neittaanmäki-Perttu, Noora; Grönroos, Mari; Karppinen, Toni; Snellman, Erna; Rissanen, Pekka
2016-02-01
Daylight-mediated photodynamic therapy (DL-PDT) is considered as effective as conventional PDT using artificial light (light-emitting diode (LED)-PDT) for treatment of actinic keratoses (AK). This randomized prospective non-sponsored study assessed the cost-effectiveness of DL-PDT compared with LED-PDT. Seventy patients with 210 AKs were randomized to DL-PDT or LED-PDT groups. Effectiveness was assessed at 6 months. The costs included societal costs and private costs, including the time patients spent in treatment. Results are presented as incremental cost-effectiveness ratio (ICER). The total costs per patient were significantly lower for DL-PDT (€132) compared with LED-PDT (€170), giving a cost saving of €38 (p = 0.022). The estimated probabilities for patients' complete response were 0.429 for DL-PDT and 0.686 for LED-PDT; a difference in probability of being healed of 0.257. ICER showed a monetary gain of €147 per unit of effectiveness lost. DL-PDT is less costly and less effective than LED-PDT. In terms of cost-effectiveness analysis, DL-PDT provides lower value for money compared with LED-PDT.
ERIC Educational Resources Information Center
Gleed, Amy Keller
2009-01-01
Daylighting a space is both an art and a science. The impact of daylight can make a building's design come to life. Daylighting can be carried out skillfully, or it can be too casually considered or totally misunderstood. Bad daylighting is devastating to a space and costly to fix. Today, in this era of sustainable design, daylighting is given…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geisler-Moroder, David; Lee, Eleanor S.; Ward, Gregory J.
2016-08-29
The Five-Phase Method (5-pm) for simulating complex fenestration systems with Radiance is validated against field measurements. The capability of the method to predict workplane illuminances, vertical sensor illuminances, and glare indices derived from captured and rendered high dynamic range (HDR) images is investigated. To be able to accurately represent the direct sun part of the daylight not only in sensor point simulations, but also in renderings of interior scenes, the 5-pm calculation procedure was extended. The validation shows that the 5-pm is superior to the Three-Phase Method for predicting horizontal and vertical illuminance sensor values as well as glare indicesmore » derived from rendered images. Even with input data from global and diffuse horizontal irradiance measurements only, daylight glare probability (DGP) values can be predicted within 10% error of measured values for most situations.« less
Simulation of tree shade impacts on residential energy use for space conditioning in Sacramento
NASA Astrophysics Data System (ADS)
Simpson, J. R.; McPherson, E. G.
Tree shade reduces summer air conditioning demand and increases winter heating load by intercepting solar energy that would otherwise heat the shaded structure. We evaluate the magnitude of these effects here for 254 residential properties participating in a utility sponsored tree planting program in Sacramento, California. Tree and building characteristics and typical weather data are used to model hourly shading and energy used for space conditioning for each building for a period of one year. There were an average of 3.1 program trees per property which reduced annual and peak (8 h average from 1 to 9 p.m. Pacific Daylight Time) cooling energy use 153 kWh (7.1%) and 0.08 kW (2.3%) per tree, respectively. Annual heating load increased 0.85 GJ (0.80 MBtu, 1.9%) per tree. Changes in cooling load were smaller, but percentage changes larger, for newer buildings. Averaged over all homes, annual cooling savings of 15.25 per tree were reduced by a heating penalty of 5.25 per tree, for net savings of 10.00 per tree from shade. We estimate an annual cooling penalty of 2.80 per tree and heating savings of 6.80 per tree from reduced wind speed, for a net savings of 4.00 per tree, and total annual savings of 14.00 per tree (43.00 per property). Results are found to be consistent with previous simulations and the limited measurements available.
NASA Astrophysics Data System (ADS)
Berman, Samuel
1985-11-01
Advances in research for new types of lighting with increased efficacies (lumens/watt) are discussed in the following areas: (1) high-frequency, solid-state ballasts, (2) isotopic enhancement of mercury isotopes, (3) magnetic augmentation, (4) electrodeless, ultra-high frequency, (5) tuned phosphors, (6) two-photon phosphors, (7) heat mirrors, and (8) advanced control circuits to take advantage of daylight and occupancy. As of 1985, improvements in efficacy have been accomplished on an economic basis to save energy for (1) high frequency ballasts (25%), (2) isotopic enhancement (5%), and (8) advanced control circuits (up to 50%). Most of these advances depend on a deeper understanding of the weakly ionized plasma as a radiating and diffusing medium.
Strategies to Save 50% Site Energy in Grocery and General Merchandise Stores
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirsch, A.; Hale, E.; Leach, M.
2011-03-01
This paper summarizes the methodology and main results of two recently published Technical Support Documents. These reports explore the feasibility of designing general merchandise and grocery stores that use half the energy of a minimally code-compliant building, as measured on a whole-building basis. We used an optimization algorithm to trace out a minimum cost curve and identify designs that satisfy the 50% energy savings goal. We started from baseline building energy use and progressed to more energy-efficient designs by sequentially adding energy design measures (EDMs). Certain EDMs figured prominently in reaching the 50% energy savings goal for both building types:more » (1) reduced lighting power density; (2) optimized area fraction and construction of view glass or skylights, or both, as part of a daylighting system tuned to 46.5 fc (500 lux); (3) reduced infiltration with a main entrance vestibule or an envelope air barrier, or both; and (4) energy recovery ventilators, especially in humid and cold climates. In grocery stores, the most effective EDM, which was chosen for all climates, was replacing baseline medium-temperature refrigerated cases with high-efficiency models that have doors.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-30
... Production Act of 1993--OpenDaylight Project, Inc. Notice is hereby given that, on November 13, 2013.... 4301 et seq. (``the Act''), OpenDaylight Project, Inc. (``OpenDaylight'') has filed written.... Membership in this group research project remains open, and OpenDaylight intends to file additional written...
ERIC Educational Resources Information Center
Kosik, Kenneth S.; Heschong, Lisa
An audiotape presents study analysis of the effect of daylighting on student performance. The study includes a focus on skylighting as a way to isolate daylight as an illumination source, and separate illumination effects from other qualities associated with daylighting from windows. Results from test scores of over 21,000 student records, along…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Sallal, K.A.
1999-07-01
The study aims to explore the effect of different climates on window and skylight design in residential buildings. The study house is evaluated against climates that have design opportunities for passive systems, with emphasis on passive cooling. The study applies a variety of methods to evaluate the design. It has found that earth sheltering and night ventilation have the potential to provide 12--29% and 25--77% of the cooling requirements respectively for the study house in the selected climates. The reduction of the glazing area from 174 ft{sup 2} to 115 ft{sup 2} has different impacts on the cooling energy costmore » in the different climates. In climates such Fresno and Tucson, one should put the cooling energy savings as a priority for window design, particularly when determining the window size. In other climates such as Albuquerque, the priority of window design should be first given to heating savings requirements.« less
Stress Evaluation for the TOW Accuracy Study
1991-11-01
possibi_2 effects on performance that ware because of test site factors could not be Assased . Implications of confounding order with test site were...with extended wear. There is no health risk in wearing these devices. The system is described in detail in Appendix B. The activity monitors were used... chemical protective clothing (MOPP IV). All runs were completed during daylight hoars. Each gunner completed the state questionnaire battery about 15
Shumack, Stephen; Murrell, Dedee F; Rubel, Diana M; Fernández‐Peñas, Pablo; Salmon, Robert; Hewitt, Daniel; Foley, Peter; Spelman, Lynda
2015-01-01
Abstract Australia has the highest prevalence of actinic keratoses (AK) worldwide. Because of the risk of transformation of AK to invasive squamous cell carcinomas, consensus guidelines recommend that AK are removed using appropriate therapies to prevent progression to invasive disease. Daylight photodynamic therapy (PDT) is emerging as an efficacious treatment for AK, particularly for patients who require treatment of large areas of chronic actinic damage that can be exposed easily to daylight. Daylight PDT with methyl aminolevulinate (MAL) cream is a simple treatment for AK, almost painless, well tolerated and convenient, requiring minimal time in the clinic. Randomised controlled studies from northern Europe and Australia support the use of daylight PDT as an effective therapy for grade I and II AK on the face and scalp. There is sufficient daylight to conduct daylight PDT in Australia at any time of the year and during most weather conditions. Hence, daylight PDT with MAL can be included as an effective and well‐tolerated new treatment option for the treatment of AK in Australia. These consensus recommendations provide guidelines for Australian clinicians on the use of daylight PDT in the treatment of diagnosed AK. PMID:26033230
Wood, Simon; Quinn, Alison; Troupe, Stephen; Kingsland, Charles; Lewis-Jones, Iwan
2006-12-01
The effect of seasonality and daylight length on mammalian reproduction leading to spring births has been well established, and is known as photoperiodism. In assisted reproduction there is much greater uncertainty as to the effect of seasonality. This was a 4-year retrospective analysis of 2709 standardised cycles of IVF/ICSI. Data was analysed with regard to the 1642 cycles occurring during the months of extended daylight (Apr-Sept) and those 1067 cycles during winter months of restricted light length (Oct-Mar). The results showed that there was significant improvement in assisted conception outcomes in cycles performed in summer (lighter) months with more efficient ovarian stimulation 766iu v880iu/per oocyte retrieved (p=0.006). There was similarly a significantly improved implantation rate per embryo transferred 11.42% vs 9.35% (p=0.011) and greater clinical pregnancy rate 20% vs 15% (p=0.0033) during summer cycles. This study appears to demonstrate a significant benefit of increased daylight length on outcomes of IVF/ICSI cycles. Whilst the exact mechanism of this is unclear, it would seem probable that melatonin may have actions at multiple sites and on multiple levels of the reproductive tract, and may exert a more profound effect on outcomes of assisted conception cycles than has been previously considered.
Daylighting in Schools: Improving Student Performance and Health at a Price Schools Can Afford.
ERIC Educational Resources Information Center
Plympton, Patricia; Conway, Susan; Epstein, Kyra
This document discusses evidence regarding daylighting and student performance and development, and presents four case studies of schools that have cost effectively implemented daylighting into their buildings. Case studies reveal that design and construction strategies that incorporate daylighting do not significantly increase costs over…
ERIC Educational Resources Information Center
Kennedy, Mike
2010-01-01
When the subject of buildings and daylighting arises, most people's thoughts will turn first to windows. To the uninitiated, it seems a simple formula: more windows, more daylight; fewer windows, less daylight. But designers know that effective use of daylighting in a building design involves more than just letting in light to otherwise darkened…
Theoretical solution for light transmission of a bended hollow light guide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kocifaj, Miroslav; Darula, Stanislav; Kittler, Richard
2010-08-15
Hollow light guides with very high reflective inner surfaces are novel daylight systems that collect sunlight and skylight available on the roof of buildings transporting it into deep or windowless interiors in building cores. Thus the better utilization of daylight can result in energy savings and wellbeing in these enclosed indoor spaces. An analytical complex solution of a straight tube system was solved in the HOLIGILM method with a user-friendly tool available on the http://www.holigilm.info. An even more difficult light flow transport is to be determined in bended tubes usually placed on sloped roofs where a bend is necessary tomore » adjust the vertical pass through the ceilings. This paper presents the theoretical derivation of the model with its graphical representation and coordinate system respecting backward ray-tracing bend distortions. To imagine the resulting illuminance on the horizontal plane element in the interior, the virtual ray (i.e. luminance in an elementary solid angle) has to pass the ceiling diffuser interface, the inner mirror like tube with a bend, through a roof cupola attachment to the element of the sky and sun light source. Due to this complexity and the lengthy derivation and explanations more practical applications will be published later in a separate contribution. (author)« less
Energy efficiency buildings program
NASA Astrophysics Data System (ADS)
1981-05-01
Progress is reported in developing techniques for auditing the energy performance of buildings. The ventilation of buildings and indoor air quality is discussed from the viewpoint of (1) combustion generated pollutants; (2) organic contaminants; (3) radon emanation, measurements, and control; (4) strategies for the field monitoring of indoor air quality; and (5) mechanical ventilation systems using air-to-air heat exchanges. The development of energy efficient windows to provide optimum daylight with minimal thermal losses in cold weather and minimum thermal gain in hot weather is considered as well as the production of high frequency solid state ballasts for fluorescent lights to provide more efficient lighting at a 25% savings over conventional core ballasts. Data compilation, analysis, and demonstration activities are summarized.
EVALUATION OF A PROCEDURE FOR USING DAYLIGHT PROJECTION OF FILM LOOPS IN TEACHING SKILLS.
ERIC Educational Resources Information Center
HARBY, S.F.
EQUIPMENT USING A TRANSLUCENT SCREEN AND REAR PROJECTION HAS MADE IT POSSIBLE TO PROJECT MOTION PICTURES IN DAYLIGHT (DAYLIGHT PROJECTION). FILMS CAN BE SHOWN REPEATEDLY WHEN FORMED INTO A FILM LOOP (CONTINUOUS LOOP PROJECTION). DAYLIGHT PROJECTION AND CONTINUOUS LOOP PROJECTION WERE USED TO INVESTIGATE THE FOLLOWING QUESTIONS--(1) ARE FILM LOOP…
Could Daylight Glare Be Defined Mathematically?Results of Testing the DGIN Method in Japan
NASA Astrophysics Data System (ADS)
Nazzal, Ali; Oki, Masato
Discomfort glare from daylight is a common problem without valid prediction methods so far. A new mathematical DGIN (New Daylight Glare Index) method tries to respond the challenge. This paper reports on experiments carried out in daylit office environment in Japan to test applicability of the method. Slight positive correlation was found between the DGIN and the subjective evaluation. Additionally, a high Ladaptation value together with the small ratio of Lwindow to Ladaptation was obviously experienced sufficient to neutralize the effect of glare discomfort. However, subjective assessments are poor glare indicators and not reliable in testing glare prediction methods. DGIN is a good indicator of daylight glare, and when the DGIN value is analyzed together with the measured illuminance ratios, discomfort glare from daylight can be analyzed in a quantitative manner. The DGIN method could serve architects and lighting designers in testing daylighting systems, and also guide the action of daylight responsive lighting controls.
Lerche, Catharina M; Heerfordt, Ida M; Heydenreich, Jakob; Wulf, Hans Christian
2016-02-29
Daylight-mediated photodynamic therapy (daylight PDT) is a simple and pain free treatment of actinic keratoses. Weather conditions may not always allow daylight PDT outdoors. We compared the spectrum of five different lamp candidates for indoor "daylight PDT" and investigated their ability to photobleach protoporphyrin IX (PpIX). Furthermore, we measured the amount of PpIX activating daylight available in a glass greenhouse, which can be an alternative when it is uncomfortable for patients to be outdoors. The lamps investigated were: halogen lamps (overhead and slide projector), white light-emitting diode (LED) lamp, red LED panel and lamps used for conventional PDT. Four of the five light sources were able to photobleach PpIX completely. For halogen light and the red LED lamp, 5000 lux could photobleach PpIX whereas 12,000 lux were needed for the white LED lamp. Furthermore, the greenhouse was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation (UVB) radiation passes through the greenhouse glass, so sun protection is not needed.
Lerche, Catharina M.; Heerfordt, Ida M.; Heydenreich, Jakob; Wulf, Hans Christian
2016-01-01
Daylight-mediated photodynamic therapy (daylight PDT) is a simple and pain free treatment of actinic keratoses. Weather conditions may not always allow daylight PDT outdoors. We compared the spectrum of five different lamp candidates for indoor “daylight PDT” and investigated their ability to photobleach protoporphyrin IX (PpIX). Furthermore, we measured the amount of PpIX activating daylight available in a glass greenhouse, which can be an alternative when it is uncomfortable for patients to be outdoors. The lamps investigated were: halogen lamps (overhead and slide projector), white light-emitting diode (LED) lamp, red LED panel and lamps used for conventional PDT. Four of the five light sources were able to photobleach PpIX completely. For halogen light and the red LED lamp, 5000 lux could photobleach PpIX whereas 12,000 lux were needed for the white LED lamp. Furthermore, the greenhouse was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation (UVB) radiation passes through the greenhouse glass, so sun protection is not needed. PMID:26938525
Daylighting Makes a Difference.
ERIC Educational Resources Information Center
Heschong, Lisa; Knecht, Carey
2002-01-01
Examined the role of daylight in student achievement in three schools and found a uniformly positive and statistically significant correlation between the presence of more daylight and better student test scores. Offers guidelines on designing daylit classrooms. (EV)
NASA Astrophysics Data System (ADS)
Alzoubi, Hussain Hendi
Energy consumption in buildings has recently become a major concern for environmental designers. Within this field, daylighting and solar energy design are attractive strategies for saving energy. This study seeks the integrity and the optimality of building envelopes' performance. It focuses on the transparent parts of building facades, specifically, the windows and their shading devices. It suggests a new automated method of utilizing solar energy while keeping optimal solutions for indoor daylighting. The method utilizes a statistical approach to produce mathematical equations based on physical experimentation. A full-scale mock-up representing an actual office was built. Heat gain and lighting levels were measured empirically and correlated with blind angles. Computational methods were used to estimate the power production from photovoltaic cells. Mathematical formulas were derived from the results of the experiments; these formulas were utilized to construct curves as well as mathematical equations for the purpose of optimization. The mathematical equations resulting from the optimization process were coded using Java programming language to enable future users to deal with generic locations of buildings with a broader context of various climatic conditions. For the purpose of optimization by automation under different climatic conditions, a blind control system was developed based on the findings of this study. This system calibrates the blind angles instantaneously based upon the sun position, the indoor daylight, and the power production from the photovoltaic cells. The functions of this system guarantee full control of the projected solar energy on buildings' facades for indoor lighting and heat gain. In winter, the system automatically blows heat into the space, whereas it expels heat from the space during the summer season. The study showed that the optimality of building facades' performance is achievable for integrated thermal, energy, and lighting models in buildings. There are blind angles that produce maximum energy from the photovoltaic cells while keeping indoor light within the acceptable limits that prevent undesired heat gain in summer.
Lighting system combining daylight concentrators and an artificial source
Bornstein, Jonathan G.; Friedman, Peter S.
1985-01-01
A combined lighting system for a building interior includes a stack of luminescent solar concentrators (LSC), an optical conduit made of preferably optical fibers for transmitting daylight from the LSC stack, a collimating lens set at an angle, a fixture for receiving the daylight at one end and for distributing the daylight as illumination inside the building, an artificial light source at the other end of the fixture for directing artifical light into the fixture for distribution as illumination inside the building, an automatic dimmer/brightener for the artificial light source, and a daylight sensor positioned near to the LSC stack for controlling the automatic dimmer/brightener in response to the daylight sensed. The system also has a reflector positioned behind the artificial light source and a fan for exhausting heated air out of the fixture during summer and for forcing heated air into the fixture for passage into the building interior during winter.
2012-09-01
pier and are exposed to salt water, wind , and adverse weather conditions. Utilities include electricity, potable water, and communication. Other...the NPTU Charleston piers (NOAA 2010). Daylight-only ship traffic extends upstream as far as the Nucor Steel Plant, accessing a slip for ocean-going...produced by the reactor plant is transmitted through the ship’s main engine turbine to a water break which simulates the action of a propeller without
Daylighting performance and thermal implications of skylights vs. south-facing roof monitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenbaum, M.; Coldham, B.
1997-12-31
This paper reports the results of a comparison of skylights vs. south-facing roof monitors for daylighting the north wall zone of a 10,000 ft{sup 2} office building near Manchester, NH. A physical model was constructed and tested. Simultaneously, the building`s annual thermal performance was modeled with Energy-10 hourly simulation software, and its peak heating and cooling load performance was modeled with the Carrier Corp. Hourly Analysis Program (HAP). Apertures were built into the roof of the model, and several skylight and south-facing roof monitor configurations were tested in both clear and overcast conditions. A design goal was to have themore » building be daylit on overcast as well as clear days. This goal was based more on enhancement of the working environment than it was on electrical energy savings. Monitors with overhangs performed poorly in the overcast conditions--it was determined that 2.4 times as much monitor aperture was needed to yield equivalent light levels in overcast conditions. The thermal models showed that the annual heating and cooling energy cost for the building was the same for either strategy, but that peak cooling loads and peak heating loads were lower with the skylit version. The authors concluded that skylights were preferred over monitors in this application, due to similar annual energy costs, lower peak loads, and lower construction cost.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eilert, P.L.; Hoeschele, M.
This paper discussed a market-transformation program to reduce energy use in modular school classrooms, a large part of new construction activities in California's schools. Today's modular classrooms cost more to operate than is necessary to provide effective, comfortable learning conditions for students and teachers. Although past resource acquisition programs have created a demand for efficient products and services, modular classrooms remain poorly differentiated in this respect. The cost-effectiveness of a range of potential energy efficiency measures (EEM's) were evaluated including lighting, alternative HVAC options, and improved envelope features. Viable EEM's were combined in two separate packages. The first includes measuresmore » that can easily be implemented and are projected to reduce operating costs by 30%. The second implements a daylighting system, a two-stage evaporative cooler, and radiant heating, resulting in projected annual energy cost savings over 60%. Transforming the market for modular classrooms is accomplished using natural market forces, rather than financial incentives directed at an entire industry. Proactive efforts are focused on the manufacturing industry's change leaders to commercialize energy-efficient products. Lost market share and peer pressure do the heavy lifting of convincing market followers to upgrade their products. Demand for efficient classrooms is increased by educating schools about the new products' financial advantages, comfort enhancements, and environmental benefits. As new products become established in the marketplace, support will be gradually withdrawn. The relevance of this work extends beyond California, given other States' programs to reduce class size, and the Presidents initiative to reduce class size nationally.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beltran, L.O.; Lee, E.S.; Papmichael, K.M.
1994-03-01
We present results from the design and evaluation of three advanced daylighting systems: a light shelf, a light pipe, and a skylight. These systems use optical films and an optimized geometry to passively intercept and redirect sunlight further into the building. The objectives of these designs are to increase daylighting illuminance levels at distances of 4.6-9.1 m (15--30 ft) from the window, and to improve the uniformity of the daylight distribution and the luminance gradient across the room under variable sun and sky conditions throughout the year. The designs were developed through a series of computer-assisted ray-tracing studies, photometric measurements,more » and observations using physical scale models. Comprehensive sets of laboratory measurements in combination with analytical routines were then used to simulate daylight performance for any solar position. Results show increased daylight levels and an improved luminance gradient throughout the year -- indicating that lighting energy consumption and cooling energy due of lighting can be substantially reduced with improvements to visual comfort. Future development of the designs may further improve the daylighting performance of these systems.« less
Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Birru, Dagnachew; Wen, Yao-Jung; Rubinstein, Francis M.
2013-10-28
This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach tomore » determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.« less
NASA Astrophysics Data System (ADS)
Sokol, Natalia; Martyniuk-Peczek, Justyna
2017-10-01
This paper reports on the partial results of the research aiming to illustrate how an integration of daylight design into an architectural planning process can help designers to create the residential buildings in respect to the environmental issues, solar and illuminance gains, as well as, the residents’ needs and comfort. It describes how changing daylight recommendations affected the design of the block of flats regarding their orientation, the spacing, the forms, and the size of the windows in the four urban residential areas. The results of this study help to determine more precise characterization of daylight indicators useful in architectural planning.
Daylight strategies for architectural studio facilities: the literature review
NASA Astrophysics Data System (ADS)
Othman, Muhammad Anas Bin; Azfahani Ahmad, Nur; Ajis, Azizah Md
2017-05-01
The implementation of daylighting strategies in buildings is a common aspect in architecture. However, due to the availability of inexpensive electricity, natural lighting strategies became insignificant, and been overlooked by designers. With the current concern over rapid increment on electricity cost, many designers now try to revitalized daylighting strategies in buildings. This includes educational buildings. In Malaysian cases, it is a norm that universities; especially during lecture and studio sessions, used artificial lighting throughout the day. Definitely, this is not parallel with the “green” aim made by the Government in the Malaysian Plan. Therefore, this paper aims to explore the impact of daylight strategies for educational studios in universities, by maximising the penetration of natural daylight into the space towards creating a more green-conducive studio. The paper review literature about the types, criteria and benefits of daylight strategies. This paper also presented a pilot study that has been performed in one university in Perak, Malaysia, by selecting architectural studios as the main subject.
Røislien, Jo; Søvik, Signe; Eken, Torsten
2018-01-01
Trauma is a leading global cause of death, and predicting the burden of trauma admissions is vital for good planning of trauma care. Seasonality in trauma admissions has been found in several studies. Seasonal fluctuations in daylight hours, temperature and weather affect social and cultural practices but also individual neuroendocrine rhythms that may ultimately modify behaviour and potentially predispose to trauma. The aim of the present study was to explore to what extent the observed seasonality in daily trauma admissions could be explained by changes in daylight and weather variables throughout the year. Retrospective registry study on trauma admissions in the 10-year period 2001-2010 at Oslo University Hospital, Ullevål, Norway, where the amount of daylight varies from less than 6 hours to almost 19 hours per day throughout the year. Daily number of admissions was analysed by fitting non-linear Poisson time series regression models, simultaneously adjusting for several layers of temporal patterns, including a non-linear long-term trend and both seasonal and weekly cyclic effects. Five daylight and weather variables were explored, including hours of daylight and amount of precipitation. Models were compared using Akaike's Information Criterion (AIC). A regression model including daylight and weather variables significantly outperformed a traditional seasonality model in terms of AIC. A cyclic week effect was significant in all models. Daylight and weather variables are better predictors of seasonality in daily trauma admissions than mere information on day-of-year.
Daylighting Concepts for University Libraries and Their Influences on Users' Satisfaction
ERIC Educational Resources Information Center
Kilic, Didem Kan; Hasirci, Deniz
2011-01-01
Daylighting, a controlled architectural tool that influences users' perception and behavior, in university libraries and their influences on users' preference and satisfaction was examined in this study. The effects of daylighting in coordination with visual comfort, on university library users were measured in relation to four environmental…
Heliostat design for the daylighting system.
Chang, Chih-Hung; Hsiso, Horng-Ching; Chang, Cheng-Ming; Wang, Chen-You; Lin, Tzung-Han; Chen, Yi-Yung; Lai, Yi-Lung; Yen, Cho-Jung; Chen, Kuan-Yu; Whang, Allen Jong-Woei
2014-10-10
The daylighting system is designed to guide sunlight into buildings for illumination. It has the best illumination performance when sunlight vertically impinges on the collector of the daylighting system, while it has low performance when sunlight impinges obliquely. To overcome the problem, this paper investigates the design of a heliostat that reflects sunlight vertically onto a daylighting system. This study proposes a 3×3 mirror matrix heliostat, which is different from the traditional heliostat with one single mirror. With the heliostat, the system efficiency increases as high as 3.32 times.
Tornado Strikes Southern Maryland
NASA Technical Reports Server (NTRS)
2002-01-01
Evening light catches the tops of towering thunderheads over the Mid-Atlantic states on April 28, 2002. The powerful storms spawned several tornados, one of which was classified as an F4 tornado. The powerful tornado touched down in the southern Maryland town of La Plata, destroying most of the historic downtown. The twister-one of the strongest ever to hit the state-beat a 24-mile swath running west to east through the state and claimed at least three lives. The image above was taken by the Geostationary Operational Environmental Satellite (GOES) at 7:15 PM Eastern Daylight Savings Time. A large version of the animation shows more detail. (5.9 MB Quicktime) Image courtesy National Oceanic and Atmospheric Administration (NOAA) and the GOES Project Science Office. Animation by Robert Simmon, NASA GSFC.
Activity and observability of meteor showers throughout the year
NASA Astrophysics Data System (ADS)
Zimnikoval, Peter
2014-02-01
Diagrams on the poster present the activity periods of meteor showers as well as the rising and setting times of meteor shower radiants. Plotted are sunrises, sunsets and the period of twilight. It was constructed according to data from the IMO Meteor Shower Working List. More active showers are displayed in red and less active showers in green. The diagrams are calculated for geographic latitudes of 40° N, 0° and 40° S. The time scale is given as local time at the relevant zonal meridian and supplemented by local daylight saving time. The diagrams contain rounded values of solar longitude J2000. The star chart shows the radiant positions and drift of IMO meteor showers while the other diagrams display shower activity and date of maximum.
Light Moves: Integrating Daylight into School Design from the Start
ERIC Educational Resources Information Center
Brossy de Dios, Eric; Rogic, Tinka; Vaughn, Wendell
2010-01-01
Numerous studies have demonstrated the benefits of daylight on the learning environment. Enhanced student performance and mood, increased teacher and student attendance, reduced energy costs, as well as a positive effect on the environment are some of the improvements seen in school buildings that use well-planned daylighting concepts. Looking at…
Guestworker migration, remittances and the extended family: evidence from Pakistan.
Ilahi, N; Jafarey, S
1999-04-01
"The paper places migration in the context of the extended family. It models informal loans between migrant and extended family for financing the costs of international labor migration. To show repayments to extended family is important; we trace the effects of such loans on migrant savings and remittance to the immediate family. We employ a standard life-cycle approach, which predicts that the demand for extended family financing rises with migration costs and falls with pre-migration wealth. Remittance to the immediate family and savings retained abroad both fall with the pre-migration loan." These hypotheses are tested using data from a survey of return migrants to Pakistan carried out in 1986. excerpt
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false How are redemption values determined during any extended maturity period of Series EE savings bonds with issue dates prior to May 1, 1995? 351.21 Section 351.21 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued...
Daylight and absenteeism--evidence from Norway.
Markussen, Simen; Røed, Knut
2015-01-01
Based on administrative register data from Norway, we examine the impact of hours of daylight on sick-leave absences among workers. Our preferred estimates imply that an additional hour of daylight increases the daily entry rate to absenteeism by 0.5 percent and the corresponding recovery rate by 0.8 percent, ceteris paribus. The overall relationship between absenteeism and daylight hours is negative. Absenteeism is also sensitive to weather conditions. Heavy snowfall raises the incidence of absence during the winter, while warm weather reduces the probability of returning to work during the summer. Copyright © 2014 Elsevier B.V. All rights reserved.
Application of a digital technique in evaluating the reliability of shade guides.
Cal, E; Sonugelen, M; Guneri, P; Kesercioglu, A; Kose, T
2004-05-01
There appears to be a need for a reliable method for quantification of tooth colour and analysis of shade. Therefore, the primary objective of this study was to show the applicability of graphic software in colour analysis and secondly to investigate the reliability of commercial shade guides produced by the same manufacturer, using this digital technique. After confirming the reliability and reproducibility of the digital method by using self-assessed coloured images, three shade guides of the same manufacturer were photographed in daylight and in studio environments with a digital camera and saved in tagged image file format (TIFF) format. Colour analysis of each photograph was performed using the Adobe Photoshop 4.0 graphic program. Luminosity, and red, green, blue (L and RGB) values of each shade tab of each shade guide were measured and the data were subjected to statistical analysis using the repeated measure Anova test. The L and RGB values of the images taken in daylight differed significantly from those of the images taken in studio environment (P < 0.05). In both environments, the luminosity and red values of the shade tabs were significantly different from each other (P < 0.05). It was concluded that, when the environmental conditions were kept constant, the Adobe Photoshop 4.0 colour analysis program could be used to analyse the colour of images. On the other hand, the results revealed that the accuracy of shade tabs widely being used in colour matching should be readdressed.
Kirchberger, Inge; Wolf, Kathrin; Heier, Margit; Kuch, Bernhard; von Scheidt, Wolfgang; Peters, Annette; Meisinger, Christa
2015-08-14
Some studies suggest that transitions to and from daylight saving time (DST) have an influence on acute myocardial infarction (AMI) incidence. However, the available publications have a number of limitations e.g. regarding sample size, exclusion of fatal AMI cases, precise assessment of AMI onset, and consideration of possible confounders, and they were conducted in countries with different geographical location. The objective of this study was to examine the association of DST transitions with AMI incidence recorded in the population-based German MONICA/KORA Myocardial Infarction Registry. The study sample consisted of 25,499 coronary deaths and non-fatal AMI cases aged 25-74 years. We used Poisson regression with indicator variables for the 3 days or the week after the spring and the autumn transition and adjusted for potential confounders to model the association between DST transitions and AMI incidence. In addition, we built an excess model by calculating observed over expected events per day. Overall, no significant changes of AMI risk during the first 3 days or 1 week after the transition to and from DST were found. However, subgroup analyses on the spring transition revealed significantly increased risks for men in the first 3 days after transition (RR 1.155, 95 % CI 1.000-1.334) and for persons who took angiotensine converting enzyme (ACE) inhibitors prior to the AMI (3 days: RR 1.489, 95 % CI 1.151-1.927; 1 week: RR 1.297, 95 % CI 1.063-1.582). After the clock shift in autumn, patients with a prior infarction had an increased risk to have a re-infarction (3 days: RR 1.319, 95 % CI 1.029-1.691; 1 week: RR 1.270, 95 % CI 1.048-1.539). Specific subgroups such as men and persons with a history of AMI or prior treatment with ACE inhibitors, may have a higher risk for AMI during DST. Further studies which include data on chronotype and sleep duration are needed in order to confirm these results.
Colorimetric analysis of outdoor illumination across varieties of atmospheric conditions.
Peyvandi, Shahram; Hernández-Andrés, Javier; Olmo, F J; Nieves, Juan Luis; Romero, Javier
2016-06-01
Solar illumination at ground level is subject to a good deal of change in spectral and colorimetric properties. With an aim of understanding the influence of atmospheric components and phases of daylight on colorimetric specifications of downward radiation, more than 5,600,000 spectral irradiance functions of daylight, sunlight, and skylight were simulated by the radiative transfer code, SBDART [Bull. Am. Meteorol. Soc.79, 2101 (1998)], under the atmospheric conditions of clear sky without aerosol particles, clear sky with aerosol particles, and overcast sky. The interquartile range of the correlated color temperatures (CCT) for daylight indicated values from 5712 to 7757 K among the three atmospheric conditions. A minimum CCT of ∼3600 K was found for daylight when aerosol particles are present in the atmosphere. Our analysis indicated that hemispheric daylight with CCT less than 3600 K may be observed in rare conditions in which the level of aerosol is high in the atmosphere. In an atmosphere with aerosol particles, we also found that the chromaticity of daylight may shift along the green-purple direction of the Planckian locus, with a magnitude depending on the spectral extinction by aerosol particles and the amount of water vapor in the atmosphere. The data analysis showed that an extremely high value of CCT, in an atmosphere without aerosol particles, for daylight and skylight at low sun, is mainly due to the effect of Chappuis absorption band of ozone at ∼600 nm. In this paper, we compare our data with well-known observations from previous research, including the ones used by the CIE to define natural daylight illuminants.
NASA Technical Reports Server (NTRS)
Griffin, Brand Norman
2010-01-01
With 1 rover, 2 astronauts and 3 days, the Apollo 17 Mission covered over 30 km, setup 10 scientific experiments and returned 110 kg of samples. This is a lot of science in a short time and the inspiration for a barebones, return-to-the-Moon strategy called Daylight Exploration. The Daylight Exploration approach poses an answer to the question, What could the Apollo crew have done with more time and today s robotics? In contrast to more ambitious and expensive strategies that create outposts then rely on pressurized rovers to drive to the science sites, Daylight Exploration is a low-overhead approach conceived to land near the scientific site, conduct Apollo-like exploration then leave before the sun goes down. A key motivation behind Daylight Exploration is cost reduction, but it does not come at the expense of scientific exploration. As a goal, Daylight Exploration provides access to the top 10 science sites by using the best capabilities of human and robotic exploration. Most science sites are within an equatorial band of 26 degrees latitude and on the Moon, at the equator, the day is 14 Earth days long; even more important, the lunar night is 14 days long. Human missions are constrained to 12 days because the energy storage systems required to operate during the lunar night adds mass, complexity and cost. In addition, short missions are beneficial because they require fewer consumables, do not require an airlock, reduce radiation exposure, minimize the dwell-time for the ascent and orbiting propulsion systems and allow a low-mass, campout accommodations. Key to Daylight Exploration is the use of piloted rovers used as tele-operated science platforms. Rovers are launched before or with the crew, and continue to operate between crew visits analyzing and collecting samples during the lunar daylight
Herron, Jonathan Blair Thomas; French, Rachel; Gilliam, Andrew Douglas
2018-01-01
Current public sector austerity measures necessitate efficiency savings throughout the NHS. Performance targets have resulted in activity being performed in the private sector, waiting list initiative lists and requests for staff to work overtime. This has resulted in staff fatigue and additional agency costs. Adoption of extended operating theatre times (0800-1800 hours) may improve productivity and efficiency, with potentially significant financial savings; however, implementation may adversely affect staff morale and patient compliance. A pilot period of four months of extended operating times (4.5 hour sessions) was completed and included all theatre surgical specialties. Outcome measures included: the number of cases completed, late starts, early finishes, cancelled operations, theatre overruns, preoperative assessment and 18-week targets. The outcomes were then compared to pre-existing normal working day operating lists (0900-1700). Theatre staff, patient and surgical trainee satisfaction with the system were also considered by use of an anonymous questionnaire. The study showed that in-session utilisation time was unchanged by extended operating hours 88.7% (vs 89.2%). The service was rated as 'good' or 'excellent' by 87.5% of patients. Over £345,000 was saved by reducing premium payments. Savings of £225,000 were made by reducing privately outsourced operation and a further £63,000 by reviewing staff hours. Day case procedures increased from 2.8 to 3.2 cases/day with extended operating. There was no significant increase in late starts (5.1% vs 6.8%) or cancellation rates (0.75% vs 1.02%). Theatre over-runs reduced from 5% to 3.4%. The 18 weeks target for surgery was achieved in 93.7% of cases (vs 88.3%). The number of elective procedures increased from 4.1 to 4.89 cases/day. Only 13.33% of trainees (n = 33) surveyed felt that extended operating had a negative impact on training. The study concludes that extended operating increased productivity from 2.8 patients per session to 3.2 patients per session with potential savings of just over £2.4 million per financial year. Extrapolating this to the other 155 trusts in England could be a potential saving of £372 million per year. Staff, trainee and patient satisfaction was unaffected. An improved 18 weeks target position was achieved with a significant reduction in private sector work. However, some staff had difficulty with arranging childcare and taking public transport and this may prevent full implementation.
Artificial light sources for simulating natural daylight and skylight.
Grum, F
1968-01-01
A review of the literature reveals the need for reliable and stable artificial light sources that can be used as simulators of daylight and skylight. In quest of such simulators a first requirement is quantitative information on the average spectral distributions of natural sources such as daylight and skylight. Recent investigations of the spectral energy characteristics of natural daylight and skylight made it possible to determine such average conditions. With these conditions established, a search was undertaken for an artificial light source that would simulate these average natural distributions with a minimum of filtering. Certain fluorescent lamps and combinations of them were considered first, but, although it was possible to achieve fairly good visual matches of daylight and skylight, the spectral characteristics and the variability of such combinations are drawbacks to their use in critical scientific work. For this purpose, therefore, xenon arc lamps were found to be superior.
A Framework for Daylighting Optimization in Whole Buildings with OpenStudio
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2016-08-12
We present a toolkit and workflow for leveraging the OpenStudio (Guglielmetti et al. 2010) platform to perform daylighting analysis and optimization in a whole building energy modeling (BEM) context. We have re-implemented OpenStudio's integrated Radiance and EnergyPlus functionality as an OpenStudio Measure. The OpenStudio Radiance Measure works within the OpenStudio Application and Parametric Analysis Tool, as well as the OpenStudio Server large scale analysis framework, allowing a rigorous daylighting simulation to be performed on a single building model or potentially an entire population of programmatically generated models. The Radiance simulation results can automatically inform the broader building energy model, andmore » provide dynamic daylight metrics as a basis for decision. Through introduction and example, this paper illustrates the utility of the OpenStudio building energy modeling platform to leverage existing simulation tools for integrated building energy performance simulation, daylighting analysis, and reportage.« less
ERIC Educational Resources Information Center
Hill, Alva L.; Lawrence, Jerry
In recent years one of the most prevalent requests directed to design architects by teachers and administrative personnel is to include in the architectural program for their new school provisions for admitting more daylight into their classrooms. This guide by the American Institute of Architects National Committee on Architecture for Education…
Colour Model for Outdoor Machine Vision for Tropical Regions and its Comparison with the CIE Model
NASA Astrophysics Data System (ADS)
Sahragard, Nasrolah; Ramli, Abdul Rahman B.; Hamiruce Marhaban, Mohammad; Mansor, Shattri B.
2011-02-01
Accurate modeling of daylight and surface reflectance are very useful for most outdoor machine vision applications specifically those which are based on color recognition. Existing daylight CIE model has drawbacks that limit its ability to predict the color of incident light. These limitations include lack of considering ambient light, effects of light reflected off the ground, and context specific information. Previously developed color model is only tested for a few geographical places in North America and its accountability is under question for other places in the world. Besides, existing surface reflectance models are not easily applied to outdoor images. A reflectance model with combined diffuse and specular reflection in normalized HSV color space could be used to predict color. In this paper, a new daylight color model showing the color of daylight for a broad range of sky conditions is developed which will suit weather conditions of tropical places such as Malaysia. A comparison of this daylight color model and daylight CIE model will be discussed. The colors of matte and specular surfaces have been estimated by use of the developed color model and surface reflection function in this paper. The results are shown to be highly reliable.
Li, Qiaoxia; Huo, Qingdi; Wang, Juan; Zhao, Jing; Sun, Kun; He, Chaoying
2016-07-07
Some plants develop a breeding system that produces both chasmogamous (CH) and cleistogamous (CL) flowers. However, the underlying molecular mechanism remains elusive. In the present study, we observed that Viola philippica develops CH flowers with short daylight, whereas an extended photoperiod induces the formation of intermediate CL and CL flowers. In response to long daylight, the respective number and size of petals and stamens was lower and smaller than those of normally developed CH flowers, and a minimum of 14-h light induced complete CL flowers that had no petals but developed two stamens of reduced fertility. The floral ABC model indicates that B-class MADS-box genes largely influence the development of the affected two-whorl floral organs; therefore, we focused on characterizing these genes in V. philippica to understand this particular developmental transition. Three such genes were isolated and respectively designated as VpTM6-1, VpTM6-2, and VpPI. These were differentially expressed during floral development (particularly in petals and stamens) and the highest level of expression was observed in CH flowers; significantly low levels were detected in intermediate CL flowers, and the lowest level in CL flowers. The observed variations in the levels of expression after floral induction and organogenesis apparently occurred in response to variations in photoperiod. Therefore, inhibition of the development of petals and stamens might be due to the downregulation of B-class MADS-box gene expression by long daylight, thereby inducing the generation of CL flowers. Our work contributes to the understanding of the adaptive evolutionary formation of dimorphic flowers in plants.
Titan brighter at twilight than in daylight
NASA Astrophysics Data System (ADS)
García Muñoz, A.; Lavvas, P.; West, R. A.
2017-04-01
Investigating the overall brightness of planets (and moons) provides insights into their envelopes and energy budgets 1-4 . Phase curves (a representation of the overall brightness versus the Sun-object-observer phase angle) for Titan have been published over a limited range of phase angles and spectral passbands 5,6 . Such information has been key to the study of the stratification, microphysics and aggregate nature of Titan's atmospheric haze 7,8 and has complemented the spatially resolved observations showing that the haze scatters efficiently in the forward direction 7,9 . Here, we present Cassini Imaging Science Subsystem whole-disk brightness measurements of Titan from ultraviolet to near-infrared wavelengths. The observations show that Titan's twilight (loosely defined as the view at phase angles ≳150°) outshines its daylight at various wavelengths. From the match between measurements and models, we show that at even larger phase angles, the back-illuminated moon will appear much brighter than when fully illuminated. This behaviour is unique in our Solar System to Titan and is caused by its extended atmosphere and the efficient forward scattering of sunlight by its atmospheric haze. We infer a solar energy deposition rate (for a solar constant of 14.9 W m-2) of (2.84 ± 0.11) × 1014 W, consistent to within one to two standard deviations with Titan's time-varying thermal emission from 2007 to 2013 10,11 . We propose that a forward scattering signature may also occur at large phase angles in the brightness of exoplanets with extended hazy atmospheres and that this signature has a valuable diagnostic potential for atmospheric characterization.
The Role of Daylighting in Skilled Nursing Short-Term Rehabilitation Facilities.
Gharaveis, Arsalan; Shepley, Mardelle McCuskey; Gaines, Kristi
2016-01-01
The aim of this study is to investigate the best placement of windows in short-term rehabilitation facilities in terms of daylighting and outdoor views by exploring the impact of windows on resident perception of stress, mood, activities, and satisfaction. The physiological and psychological benefits of daylighting have made it an increasingly important topic in multidisciplinary research. Although multiple studies have been written about the impact of daylight on physiological responses, few investigations have been made into the nonvisual effects related to resident mood, satisfaction, and stress level. In addition, researchers typically propose recommendations for quantitative aspects of illuminance, rather than addressing the behavioural outcomes. A combination of qualitative and quantitative methodologies were used to address the research questions. Thirty-four participants, who were living temporarily in the inpatient rehabilitation units of two skilled nursing facilities, were subjects in semistructured interviews and a 7-question 5-scale survey. While residents expressed the need to have direct visual access to the outdoors, they indicated that daylight was of even higher benefit. Additionally, they noted that size and location of windows impacted their stress levels, moods, and activities. More than half of the facility residents reported changing their postures for either better outdoor views or less light disturbance while sleeping. The results of this study emphasize the importance of daylighting for residents in rehabilitation units. Architects should acknowledge the role of daylighting and window views in the design of rehabilitation facilities. © The Author(s) 2015.
Simulating the energy performance of holographic glazings
NASA Astrophysics Data System (ADS)
Papamichael, K.; Beltran, L.; Furler, Reto; Lee, E. S.; Selkowitz, Steven E.; Rubin, Michael
1994-09-01
The light diffraction properties of holographic diffractive structures present an opportunity to improve the daylight performance in side-lit office spaces by redirecting and reflecting sunlight off the ceiling, providing adequate daylight illumination up to 30 ft (9.14 m) from the window wall. Prior studies of prototypical holographic glazings, installed above conventional `view' windows, have shown increased daylight levels over a deeper perimeter area than clear glass, for selected sun positions. In this study, we report on the simulation of the energy performance of prototypical holographic glazings assuming a commercial office building in the inland Los Angeles climate. The simulation of the energy performance involved determination of both luminous and thermal performance. Since the optical complexity of holographic glazings prevented the use of conventional algorithms for the simulation of their luminous performance, we used a newly developed method that combines experimentally determined directional workplane illuminance coefficients with computer-based analytical routines to determine a comprehensive set of daylight factors for many sun positions. These daylight factors were then used within the DOE-2.1D energy simulation program to determine hourly daylight and energy performance over the course of an entire year for four window orientations. Since the prototypical holographic diffractive structures considered in this study were applied on single pane clear glass, we also simulated the performance of hypothetical glazings, assuming the daylight performance of the prototype holographic glazings and the thermal performance of double-pane and low-e glazings. Finally, we addressed various design and implementation issues towards potential performance improvement.
Prioritizing Sleep Health: Public Health Policy Recommendations.
Barnes, Christopher M; Drake, Christopher L
2015-11-01
The schedules that Americans live by are not consistent with healthy sleep patterns. In addition, poor access to educational and treatment aids for sleep leaves people engaging in behavior that is harmful to sleep and forgoing treatment for sleep disorders. This has created a sleep crisis that is a public health issue with broad implications for cognitive outcomes, mental health, physical health, work performance, and safety. New public policies should be formulated to address these issues. We draw from the scientific literature to recommend the following: establishing national standards for middle and high school start times that are later in the day, stronger regulation of work hours and schedules, eliminating daylight saving time, educating the public regarding the impact of electronic media on sleep, and improving access to ambulatory in-home diagnostic testing for sleep disorders. © The Author(s) 2015.
Holographic diffractive structures for daylighting, phase 1
NASA Astrophysics Data System (ADS)
1985-10-01
Advanced Environmental Research Group (AERG) has researched and developed a proprietary device which will passively track the Sun throughout a wide range of latitudes, hours of the day and seasons of the year. The Holographic Diffractive Structure (HDS), consists of novel holographic diffraction grating designs applied to a substrate suitable for mounting or incorporated into window glazings. The HDS installations will be a low cost system for the controlled management of sunlight in buildings for energy savings and an enhanced lighting environment. The HDSs act to intercept sunlight and redirect it away from the immediate window area towards the darker regions at the rear of the room, or (via light guides) to interior spaces without windows, or (used on the facade of a building) to redirect sunlight into dark urban canyons or onto the facades of other nearby buildings.
Hassebo, Yasser Y; Gross, Barry; Oo, Min; Moshary, Fred; Ahmed, Samir
2006-08-01
The impact and potential of a polarization-selection technique to reduce the sky background signal for linearly polarized monostatic elastic backscatter lidar measurements are examined. Taking advantage of naturally occurring polarization properties in scattered skylight, we devised a polarization-discrimination technique in which both the lidar transmitter and the receiver track and minimize detected sky background noise while maintaining maximum lidar signal throughput. Lidar elastic backscatter measurements, carried out continuously during daylight hours at 532 nm, show as much as a factor of square root 10 improvement in the signal-to-noise ratio (SNR) over conventional unpolarized schemes. For vertically pointing lidars, the largest improvements are limited to the early morning and late afternoon hours, while for lidars scanning azimuthally and in elevation at angles other than vertical, significant improvements are achievable over more extended time periods with the specific times and improvement factors depending on the specific angle between the lidar and the solar axes. The resulting diurnal variations in SNR improvement sometimes show an asymmetry with the solar angle that analysis indicates can be attributed to changes in observed relative humidity that modifies the underlying aerosol microphysics and observed optical depth.
NASA Astrophysics Data System (ADS)
Hassebo, Yasser Y.; Gross, Barry; Oo, Min; Moshary, Fred; Ahmed, Samir
2006-08-01
The impact and potential of a polarization-selection technique to reduce the sky background signal for linearly polarized monostatic elastic backscatter lidar measurements are examined. Taking advantage of naturally occurring polarization properties in scattered skylight, we devised a polarization-discrimination technique in which both the lidar transmitter and the receiver track and minimize detected sky background noise while maintaining maximum lidar signal throughput. Lidar elastic backscatter measurements, carried out continuously during daylight hours at 532 nm, show as much as a factor of square root 10 improvement in the signal-to-noise ratio (SNR) over conventional unpolarized schemes. For vertically pointing lidars, the largest improvements are limited to the early morning and late afternoon hours, while for lidars scanning azimuthally and in elevation at angles other than vertical, significant improvements are achievable over more extended time periods with the specific times and improvement factors depending on the specific angle between the lidar and the solar axes. The resulting diurnal variations in SNR improvement sometimes show an asymmetry with the solar angle that analysis indicates can be attributed to changes in observed relative humidity that modifies the underlying aerosol microphysics and observed optical depth.
Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office testbed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thanachareonkit, Anothai; Lee, Eleanor S.; McNeil, Andrew
2013-08-31
Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Microstructured prismatic window films can be manufactured using low-cost, roll-to-roll fabrication methods and adhered to the inside surface of existing windows as a retrofit measure or installed as a replacement insulating glass unit in the clerestory portion of the window wall. A clear film patterned with linear, 50-250 micrometer high, four-sided asymmetrical prisms was fabricated and installed in the south-facing, clerestory low-e, clear glazed windows of a full-scale testbed facility. Views through the film were distorted. The film was evaluated in amore » sunny climate over a two-year period to gauge daylighting and visual comfort performance. The daylighting aperture was small (window-towall ratio of 0.18) and the lower windows were blocked off to isolate the evaluation to the window film. Workplane illuminance measurements were made in the 4.6 m (15 ft) deep room furnished as a private office. Analysis of discomfort glare was conducted using high dynamic range imaging coupled with the evalglare software tool, which computes the daylight glare probability and other metrics used to evaluate visual discomfort. The window film was found to result in perceptible levels of discomfort glare on clear sunny days from the most conservative view point in the rear of the room looking toward the window. Daylight illuminance levels at the rear of the room were significantly increased above the reference window condition, which was defined as the same glazed clerestory window but with an interior Venetian blind (slat angle set to the cut-off angle), for the equinox to winter solstice period on clear sunny days. For partly cloudy and overcast sky conditions, daylight levels were improved slightly. To reduce glare, the daylighting film was coupled with a diffusing film in an insulating glazing unit. The diffusing film retained the directionality of the redirected light spreading it within a small range of outgoing angles. This solution was found to reduce glare to imperceptible levels while retaining for the most part the illuminance levels achieved solely by the daylighting film.« less
31 CFR 332.8 - Extended terms and yield for outstanding bonds.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Extended terms and yield for... SAVINGS BONDS, SERIES H § 332.8 Extended terms and yield for outstanding bonds. (a) Extended maturity period—(1) General. The terms extended maturity period, and second extended maturity period, when used...
31 CFR 316.8 - Extended terms and yields for outstanding bonds.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Extended terms and yields for... SAVINGS BONDS, SERIES E § 316.8 Extended terms and yields for outstanding bonds. (a) General. The terms extended maturity period, second extended maturity period, third extended maturity period and fourth...
31 CFR 342.3 - Extended terms and yields for outstanding notes.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Extended terms and yields for... SAVINGS NOTES § 342.3 Extended terms and yields for outstanding notes. (a) Extended maturity periods. The terms extended maturity period and second extended maturity period refer to the 10-year intervals after...
31 CFR 316.8 - Extended terms and yields for outstanding bonds.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Extended terms and yields for... SAVINGS BONDS, SERIES E § 316.8 Extended terms and yields for outstanding bonds. (a) General. The terms extended maturity period, second extended maturity period, third extended maturity period and fourth...
31 CFR 316.8 - Extended terms and yields for outstanding bonds.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Extended terms and yields for... SAVINGS BONDS, SERIES E § 316.8 Extended terms and yields for outstanding bonds. (a) General. The terms extended maturity period, second extended maturity period, third extended maturity period and fourth...
31 CFR 342.3 - Extended terms and yields for outstanding notes.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Extended terms and yields for... SAVINGS NOTES § 342.3 Extended terms and yields for outstanding notes. (a) Extended maturity periods. The terms extended maturity period and second extended maturity period refer to the 10-year intervals after...
31 CFR 342.3 - Extended terms and yields for outstanding notes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Extended terms and yields for... SAVINGS NOTES § 342.3 Extended terms and yields for outstanding notes. (a) Extended maturity periods. The terms extended maturity period and second extended maturity period refer to the 10-year intervals after...
31 CFR 316.8 - Extended terms and yields for outstanding bonds.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Extended terms and yields for... SAVINGS BONDS, SERIES E § 316.8 Extended terms and yields for outstanding bonds. (a) General. The terms extended maturity period, second extended maturity period, third extended maturity period and fourth...
31 CFR 332.8 - Extended terms and yield for outstanding bonds.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Extended terms and yield for... SAVINGS BONDS, SERIES H § 332.8 Extended terms and yield for outstanding bonds. (a) Extended maturity period—(1) General. The terms extended maturity period, and second extended maturity period, when used...
31 CFR 316.8 - Extended terms and yields for outstanding bonds.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Extended terms and yields for... SAVINGS BONDS, SERIES E § 316.8 Extended terms and yields for outstanding bonds. (a) General. The terms extended maturity period, second extended maturity period, third extended maturity period and fourth...
31 CFR 342.3 - Extended terms and yields for outstanding notes.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Extended terms and yields for... SAVINGS NOTES § 342.3 Extended terms and yields for outstanding notes. (a) Extended maturity periods. The terms extended maturity period and second extended maturity period refer to the 10-year intervals after...
31 CFR 332.8 - Extended terms and yield for outstanding bonds.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Extended terms and yield for... SAVINGS BONDS, SERIES H § 332.8 Extended terms and yield for outstanding bonds. (a) Extended maturity period—(1) General. The terms extended maturity period, and second extended maturity period, when used...
31 CFR 342.3 - Extended terms and yields for outstanding notes.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Extended terms and yields for... SAVINGS NOTES § 342.3 Extended terms and yields for outstanding notes. (a) Extended maturity periods. The terms extended maturity period and second extended maturity period refer to the 10-year intervals after...
31 CFR 332.8 - Extended terms and yield for outstanding bonds.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Extended terms and yield for... SAVINGS BONDS, SERIES H § 332.8 Extended terms and yield for outstanding bonds. (a) Extended maturity period—(1) General. The terms extended maturity period, and second extended maturity period, when used...
31 CFR 332.8 - Extended terms and yield for outstanding bonds.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Extended terms and yield for... SAVINGS BONDS, SERIES H § 332.8 Extended terms and yield for outstanding bonds. (a) Extended maturity period—(1) General. The terms extended maturity period, and second extended maturity period, when used...
Center for the Built Environment: Setpoint Energy Savings Calculator
. Arens, and H. Zhang, 2014. Extending air temperature setpoints: Simulated energy savings and design Near-ZNE Buildings Setpoint Energy Savings Calculator UFAD Case Studies UFAD Cooling Design Tool UFAD Cost Analysis UFAD Design Guide UFAD East End UFAD Energy Modeling UFAD Plenum Performance UFAD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuo, Wangda; McNeil, Andrew; Wetter, Michael
2013-05-23
Building designers are increasingly relying on complex fenestration systems to reduce energy consumed for lighting and HVAC in low energy buildings. Radiance, a lighting simulation program, has been used to conduct daylighting simulations for complex fenestration systems. Depending on the configurations, the simulation can take hours or even days using a personal computer. This paper describes how to accelerate the matrix multiplication portion of a Radiance three-phase daylight simulation by conducting parallel computing on heterogeneous hardware of a personal computer. The algorithm was optimized and the computational part was implemented in parallel using OpenCL. The speed of new approach wasmore » evaluated using various daylighting simulation cases on a multicore central processing unit and a graphics processing unit. Based on the measurements and analysis of the time usage for the Radiance daylighting simulation, further speedups can be achieved by using fast I/O devices and storing the data in a binary format.« less
Daylighting in the Springfield (Ohio) Museum of Art
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moore, F.
This paper describes daylighting strategies used in the addition to the Springfield Museum of Art, Springfield, Ohio. The interior daylighting illuminances and luminances have been measured and these data are presented. The original museum was built in 1958. This original portion is approximately 18,000 ft{sup 2} (1,674 m{sup 2}) floor area and was remodeled as part of the 1995 addition to house and art school, cataloging, preparation, and administrative functions. The new addition is approximately 10,000 ft{sup 2} (930 m{sup 2}) and is primarily exhibit galleries with some additional administrative offices. Glaser Associated were the architects (Michael Moose, project architect)more » and the author was the daylighting consultant on the project.« less
Performance of a novel multiple-signal luminescence sediment tracing method
NASA Astrophysics Data System (ADS)
Reimann, Tony
2014-05-01
Optically Stimulated Luminescence (OSL) is commonly used for dating sediments. Luminescence signals build up due to exposure of mineral grains to natural ionizing radiation, and are reset when these grains are exposed to (sun)light during sediment transport and deposition. Generally, luminescence signals can be read in two ways, potentially providing information on the burial history (dating) or the transport history (sediment tracing) of mineral grains. In this study we use a novel luminescence measurement procedure (Reimann et al., submitted) that simultaneously monitors six different luminescence signals from the same sub-sample (aliquot) to infer the transport history of sand grains. Daylight exposure experiments reveal that each of these six signals resets (bleaches) at a different rate, thus allowing to trace the bleaching history of the sediment in six different observation windows. To test the feasibility of luminescence sediment tracing in shallow-marine coastal settings we took eight sediment samples from the pilot mega-nourishment Zandmotor in Kijkduin (South-Holland). This site provides relatively controlled conditions as the morphological evolution of this nourishment is densely monitored (Stive et al., 2013). After sampling the original nourishment source we took samples along the seaward facing contour of the spit that was formed from August 2011 (start of nourishment) to June 2012 (sampling). It is presumed that these samples originate from the source and were transported and deposited within the first year after construction. The measured luminescence of a sediment sample was interpolated onto the daylight bleaching curve of each signal to assign the Equivalent Exposure Time (EET) to a sample. The EET is a quantitative measure of the full daylight equivalent a sample was exposed to during sediment transport, i.e. the higher the EET the longer the sample has been transported or the more efficient it has been exposed to day-light during sediment transport. The EET increases with increasing distance from the nourishment source, indicating that our method is capable to quantify sediment transport distances. We furthermore observed that the EET of an aeolian analogue is orders of magnitudes higher than those of the water-lain transported Zandmotor samples, suggesting that our approach is also able to differentiate between different modes of coastal sediment transport. This new luminescence approach offers new possibilities to decipher the sedimentation history of palaeo-environmental archives e.g. in coastal, fluvial or aeolian settings. References: Reimann, T.et al. Quantifying the degreeof bleaching during sediment transport using a polymineral multiple-signalluminescence approach. Submitted. Stive, M.J.F. et al. 2013. A New Alternative to Saving Our Beaches from Sea-Level Rise: The SandEngine. Journal of Coastal research 29, 1001-1008.
Gilaberte, Y; Aguilar, M; Almagro, M; Correia, O; Guillén, C; Harto, A; Pérez-García, B; Pérez-Pérez, L; Redondo, P; Sánchez-Carpintero, I; Serra-Guillén, C; Valladares, L M
2015-10-01
Daylight-mediated photodynamic therapy (PDT) is a new type of PDT that is as effective as conventional PDT in grade 1 and 2 actinic keratosis but with fewer adverse effects, resulting in greater efficiency. The climatic conditions in the Iberian Peninsula require an appropriately adapted consensus protocol. We describe a protocol for the treatment of grade 1 and 2 actinic keratosis with daylight-mediated PDT and methyl aminolevulinate (MAL) adapted to the epidemiological and clinical characteristics of Spanish and Portuguese patients and the climatic conditions of both countries. Twelve dermatologists from different parts of Spain and Portugal with experience in the treatment of actinic keratosis with PDT convened to draft a consensus statement for daylight-mediated PDT with MAL in these countries. Based on a literature review and their own clinical experience, the group developed a recommended protocol. According to the recommendations adopted, patients with multiple grade 1 and 2 lesions, particularly those at risk of developing cancer, are candidates for this type of therapy. Daylight-mediated PDT can be administered throughout the year, although it is not indicated at temperatures below 10°C or at excessively high temperatures. Likewise, therapy should not be administered when it is raining, snowing, or foggy. The procedure is simple, requiring application of a sunscreen with a protection factor of at least 30 based exclusively on organic filters, appropriate preparation of the lesions, application of MAL without occlusion, and activation in daylight for 2hours. This consensus statement represents a practical and detailed guideline to achieve maximum effectiveness of daylight-mediated PDT with MAL in Spain and Portugal with minimal adverse effects. Copyright © 2015 Elsevier España, S.L.U. and AEDV. All rights reserved.
Autonomous physics-based color learning under daylight
NASA Astrophysics Data System (ADS)
Berube Lauziere, Yves; Gingras, Denis J.; Ferrie, Frank P.
1999-09-01
An autonomous approach for learning the colors of specific objects assumed to have known body spectral reflectances is developed for daylight illumination conditions. The main issue is to be able to find these objects autonomously in a set of training images captured under a wide variety of daylight illumination conditions, and to extract their colors to determine color space regions that are representative of the objects' colors and their variations. The work begins by modeling color formation under daylight using the color formation equations and the semi-empirical model of Judd, MacAdam and Wyszecki (CIE daylight model) for representing the typical spectral distributions of daylight. This results in color space regions that serve as prior information in the initial phase of learning which consists in detecting small reliable clusters of pixels having the appropriate colors. These clusters are then expanded by a region growing technique using broader color space regions than those predicted by the model. This is to detect objects in a way that is able to account for color variations which the model cannot due to its limitations. Validation on the detected objects is performed to filter out those that are not of interest and to eliminate unreliable pixel color values extracted from the remaining ones. Detection results using the color space regions determined from color values obtained by this procedure are discussed.
Tomás-Velázquez, A; Redondo, P
2017-05-01
Actinic keratosis is a precursor lesion to the most common nonmelanoma skin cancer. Conventional photodynamic therapy (PDT) has been shown to be effective, but the procedure is time-consuming, can be very painful, and requires infrastructure. These shortcomings led to the emergence of daylight PDT. To obtain a global estimate of efficacy, we undertook a systematic literature review and performed a meta-analysis of the available evidence on the efficacy and safety of daylight PDT as compared to conventional PDT in the treatment of actinic keratosis and/or field cancerization. The conclusion is that the difference in efficacy is clinically negligible (global estimate of the mean response rate difference, -3.69%; 95% CI, -6.54% to -0.84%). The adverse effects of daylight PDT are mild and localized (79% of patients report no discomfort), and patients report less pain (P<.001). Daylight PDT gives good to excellent cosmetic results in more than 90% of patients, and patient satisfaction is greater (P<.001). Copyright © 2016 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.
Web survey of sleep problems associated with early-onset bipolar spectrum disorders.
Lofthouse, Nicholas; Fristad, Mary; Splaingard, Mark; Kelleher, Kelly; Hayes, John; Resko, Susan
2008-05-01
As research on sleep difficulties associated with Early-Onset Bipolar Spectrum Disorders (EBSD) is limited, a web-based survey was developed to further explore these problems. 494 parents of 4-to-12 year-olds, identified by parents as being diagnosed with EBSD, completed a web survey about past and current EBSD-related sleep problems. The survey included Children's Sleep Habits Questionnaire (CSHQ) items and sleep problems from the International Classification of Sleep Disorders 2nd edition. Nearly all parents reported some type of past or current EBSD-sleep problem. Most occurred during a worst mood period, particularly with mixed manic-depressive symptoms. Symptoms caused impairments at home, school, or with peers in 96.9% of the sample and across all three contexts in 64.0% of children. Sleep problems were also noted after three-day weekends and Spring and Fall Daylight Savings time changes. Findings, study limitations, and implications for treatment and etiology are discussed.
In Search of a Good Night's Sleep.
Leahy, Laura G
2017-10-01
A good night's sleep is essential to overall physical, cognitive, and emotional well-being. Sleep deprivation, whether general or related to time changes (e.g., daylight saving time), contributes to decreased cognition, impaired memory, poor coordination, mood fluctuations, increased risk of heart disease and diabetes, and weight gain, among others. The sleep cycle is defined by five stages and two distinct parts-rapid eye movement (REM) and non-REM sleep-that work to promote not only the quantity of sleep but also the quality of sleep, which impacts overall health. Each stage of sleep is influenced by various neurochemical actions among the brain regions. The neurochemistry and neuropath-ways related to the sleep/wake cycle as well as the mechanisms of action of sleep-inducing and wake-promoting medications are explored. [Journal of Psychosocial Nursing and Mental Health Services, 55(10), 19-26.]. Copyright 2017, SLACK Incorporated.
1999-09-20
c o i b f t c c c c w n c s p t s Calculating correlated color temperatures across the entire gamut of daylight and skylight chromaticities Javier...temperature ~CCT!, yet existing equations for calculating CCT from chromaticity coordinates span only part of this range. To improve both the gamut and accuracy...00-1999 to 00-00-1999 4. TITLE AND SUBTITLE Calculating correlated color temperatures across the entire gamut of daylight and skylight
Mountain Retail Stores Become Showcase for Solar Energy
-seam metal roof, a transpired solar collector (solar wall), daylighting, energy efficient windows and during daytime hours. The Bighorn Center's final design includes clerestory windows for daylighting and a
Designing a practical system for spectral imaging of skylight.
López-Alvarez, Miguel A; Hernández-Andrés, Javier; Romero, Javier; Lee, Raymond L
2005-09-20
In earlier work [J. Opt. Soc. Am. A 21, 13-23 (2004)], we showed that a combination of linear models and optimum Gaussian sensors obtained by an exhaustive search can recover daylight spectra reliably from broadband sensor data. Thus our algorithm and sensors could be used to design an accurate, relatively inexpensive system for spectral imaging of daylight. Here we improve our simulation of the multispectral system by (1) considering the different kinds of noise inherent in electronic devices such as change-coupled devices (CCDs) or complementary metal-oxide semiconductors (CMOS) and (2) extending our research to a different kind of natural illumination, skylight. Because exhaustive searches are expensive computationally, here we switch to a simulated annealing algorithm to define the optimum sensors for recovering skylight spectra. The annealing algorithm requires us to minimize a single cost function, and so we develop one that calculates both the spectral and colorimetric similarity of any pair of skylight spectra. We show that the simulated annealing algorithm yields results similar to the exhaustive search but with much less computational effort. Our technique lets us study the properties of optimum sensors in the presence of noise, one side effect of which is that adding more sensors may not improve the spectral recovery.
Super Blood Moon Lunar Eclipse
2017-12-08
What time will you be able to view the Super Moon Eclipse? The images below show times to view it for Eastern Daylight Time (EDT), Central Daylight Time (CDT), Mountain Daylight Time (MDT) and Pacific Daylight Time (PDT). All of South America and most of North and Central America will see the entire eclipse, while those west of roughly 120°W will see it in progress at moonrise. You won’t need special equipment to see it. Just go outside and look up! NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Obituary: Ian R. Bartky, 1934-2007
NASA Astrophysics Data System (ADS)
Dick, Steven J.
2009-01-01
Ian Robertson Bartky, a physical chemist who turned to history for his second career, died 18 December 2007 of complications from lung cancer. He was 73. In addition to his scientific career, he will be remembered for his meticulous research on the evolution of time systems, especially for his two books Selling the True Time: Nineteenth Century Timekeeping in America (Stanford University Press, 2000), and One Time Fits All: The Campaigns for Global Uniformity (Stanford University Press, 2007). Ian was born on 15 March 1934 in Chicago, Illinois. He was the son of Walter Bartky, a Professor of Astronomy at the University of Chicago, and eventually its Dean of the Division of Physical Sciences. The elder Bartky's astronomy textbook, Highlights of Astronomy, published in 1935 and reprinted as late as 1964, includes a considerable discussion of time and standard meridians, which may have influenced Ian, even though his father died in 1958 at the age of 57 when Ian would have been only in his early 20s. Imbued with the love of science from his father, Ian graduated from Illinois Institute of Technology, and went on to obtain his doctorate in physical chemistry from the University of California Berkeley. He mentor was Nobelist William F. Giauque, and Ian always spoke fondly of Giauque's influence in setting rigorous standards that Ian followed when he joined the National Bureau of Standards [NBS] in 1961. Ian spent most of his career there, and it was there that he acquired his professional interest in time, notably when the House Commerce Committee asked him in the mid-1970s to determine whether the dates of Daylight Saving Time should be extended. This resulted in an NBS report in 1976, which concluded that any energy savings would be miniscule. With his usual attention to detail, Ian researched the entire history of the problem, and thus acquired his second great love after science--history. With Elizabeth Harrison he published a well-known article on the issues involved with Daylight Saving Time in Scientific American for 1979. My first interaction with Ian was leading up to the 150th anniversary of the United States Naval Observatory [USNO] in December 1980. While working on an article for Sky and Telescope on the early history of the Naval Observatory, I ran across documents in the National Archives from England proposing that the Navy's new Depot of Charts and Instruments--forerunner of the Observatory--erect a time ball as had been done in Portsmouth England in 1829. Ian had been in the National Archives working on the history of time. When I mentioned this 1829 document, he said it was impossible, because the first time ball in the world was in 1833 at Greenwich, England. But the documents told the story, and this Eureka moment led to our article in the Journal for the History of Astronomy (volume 12, October 1981), on the world's first time ball. This was to the considerable chagrin of the staff at Greenwich, who thought they had the world's first time ball, and who still ceremonially drop one at 1 PM local time. Ian went on to write the history of time balls for the Naval Observatory's sesquicentennial symposium at the end of 1980, as published in Sky with Ocean Joined. We then collaborated on another article for JHA (volume 13, February 1982) on the history of the first North American time ball, dropped at the USNO beginning in 1845. Time balls and Daylight Saving Time were only a small part of Ian's interest in time as he began to untangle the many issues involved in the history of timekeeping and time dissemination. His book Selling the True Time is a model of scholarship, and with it Ian proved to have that rare combination--a scientist with deep technical knowledge who could also ask and answer profound historical questions. He also had a keen appreciation of the role of human nature in history, always looking for the motivations for particular historical actions. Ian was proud to have the book published by Stanford University Press. When Stanford also published his final book One Time Fits All: The Campaigns for Global Uniformity, he was very proud of the glowing endorsement from Peter Galison, one of the country's foremost historians of science. With this book Ian also became the world's expert on the International Date Line, time zones, and standard time, among other aspects of time. Ian's historical work was supported by the National Science Foundation, the Dudley Observatory, and the National Maritime Museum of the Royal Observatory at Greenwich, where his work was highly regarded. He was active in many professional organizations, including the Historical Astronomy Division of the American Astronomical Society. On 29 March 2008 almost exactly 50 years after the death of his father, a memorial service was held in the library of the U. S. Naval Observatory, which had become Ian's second home during his researches, often accompanied by his wife Betty, to whom he dedicated his last book, calling her his "steadfast partner in this endeavor." The service, entitled "The Time of His Life: A Celebration of Research in the Development of Standard Timekeeping," included remarks by numerous colleagues and friends, surrounded by the books he so loved. Ian is survived by his wife of 47 years, Elizabeth Hodgins Bartky of Bethesda, Maryland, a son David J. Bartky, and a daughter Anne B. Goldberg.
Bogers, Jan P.A.M.; Bostoen, Tijmen; Broekman, Theo G.
2016-01-01
Low vitamin D levels are associated with schizophrenia, but the possible association between vitamin D levels and illness severity or duration of exposure to daylight has barely been investigated. To compare vitamin D levels in therapy-refractory severely ill schizophrenia patients and members of staff. To investigate the influence of daylight exposure on vitamin D levels in patients. Vitamin D was measured in patients with therapy-resistant schizophrenia in April, after the winter, and in patients and staff members in June, after an exceptionally sunny spring. Vitamin D levels in April and June were compared in patients, and levels in June were compared in patients and staff. The influence of daylight was taken into account by comparing the time patients spent outdoors during the day with the recommended minimum time for adequate vitamin D synthesis, and by comparing time spent outdoors in patients and staff. Patients had high rates of vitamin D deficiency (79-90%) and lower levels of vitamin D than staff members (p < 0.001), independent of skin pigmentation. In patients, vitamin D levels did not normalize, despite the considerably longer than recommended exposure of the skin to daylight (p < 0.001) and the longer exposure in patients than in staff members (p = 0.003). The vitamin D deficiency of therapy-resistant schizophrenia patients is pronounced and cannot be explained by differences in skin pigmentation or by an inactive, indoor lifestyle on the ward. Even theoretically sufficient exposure of the patients to daylight did not ameliorate the low vitamin D levels. While vitamin D deficiency probably plays a role in somatic health problems, it may also play a role in schizophrenia. Interestingly, exposure to daylight during an unusually sunny spring was not sufficient to correct the vitamin D deficiency seen in the patients. This emphasizes the need to measure and correct vitamin D levels in these patients.
Variable area light reflecting assembly
Howard, T.C.
1986-12-23
Device is described for tracking daylight and projecting it into a building. The device tracks the sun and automatically adjusts both the orientation and area of the reflecting surface. The device may be mounted in either a wall or roof of a building. Additionally, multiple devices may be employed in a light shaft in a building, providing daylight to several different floors. The preferred embodiment employs a thin reflective film as the reflecting device. One edge of the reflective film is fixed, and the opposite end is attached to a spring-loaded take-up roller. As the sun moves across the sky, the take-up roller automatically adjusts the angle and surface area of the film. Additionally, louvers may be mounted at the light entrance to the device to reflect incoming daylight in an angle perpendicular to the device to provide maximum reflective capability when daylight enters the device at non-perpendicular angles. 9 figs.
Variable area light reflecting assembly
Howard, Thomas C.
1986-01-01
Device for tracking daylight and projecting it into a building. The device tracks the sun and automatically adjusts both the orientation and area of the reflecting surface. The device may be mounted in either a wall or roof of a building. Additionally, multiple devices may be employed in a light shaft in a building, providing daylight to several different floors. The preferred embodiment employs a thin reflective film as the reflecting device. One edge of the reflective film is fixed, and the opposite end is attached to a spring-loaded take-up roller. As the sun moves across the sky, the take-up roller automatically adjusts the angle and surface area of the film. Additionally, louvers may be mounted at the light entrance to the device to reflect incoming daylight in an angle perpendicular to the device to provide maximum reflective capability when daylight enters the device at non-perpendicular angles.
Daylight levels during the solar eclipse of 11 August 1999
NASA Astrophysics Data System (ADS)
Darula, S.; Kambezidis, H. D.; Kittler, R.
Solar eclipses are unique phenomena not only for astronomical and space observations but also for terrestrial; they create unique conditions of sunbeam blockage which cause not only the reduction of direct sunlight but also the dimming of skylight from the whole sky vault. Very favorable conditions were met during the recent August 1999 solar eclipse in Athens, Greece and Bratislava, Slovakia. General class daylight stations operate within the International Daylight Measurements Program in the two cities. One-minute data of global/diffuse illuminance and zenith luminance from those stations have been used to provide information about their levels and the daylight reduction rate during the eclipse. An approximate formula for the estimation of sunlight and skylight illuminance levels as well as zenith luminance using relative luminance sky patterns is also presented in this work. To achieve this, recently developed sky standards together with their parameterizations are utilized.
Hardware-in-the-Loop Modeling and Simulation Methods for Daylight Systems in Buildings
NASA Astrophysics Data System (ADS)
Mead, Alex Robert
This dissertation introduces hardware-in-the-loop modeling and simulation techniques to the daylighting community, with specific application to complex fenestration systems. No such application of this class of techniques, optimally combining mathematical-modeling and physical-modeling experimentation, is known to the author previously in the literature. Daylighting systems in buildings have a large impact on both the energy usage of a building as well as the occupant experience within a space. As such, a renewed interest has been placed on designing and constructing buildings with an emphasis on daylighting in recent times as part of the "green movement.''. Within daylighting systems, a specific subclass of building envelope is receiving much attention: complex fenestration systems (CFSs). CFSs are unique as compared to regular fenestration systems (e.g. glazing) in the regard that they allow for non-specular transmission of daylight into a space. This non-specular nature can be leveraged by designers to "optimize'' the times of the day and the days of the year that daylight enters a space. Examples of CFSs include: Venetian blinds, woven fabric shades, and prismatic window coatings. In order to leverage the non-specular transmission properties of CFSs, however, engineering analysis techniques capable of faithfully representing the physics of these systems are needed. Traditionally, the analysis techniques available to the daylighting community fall broadly into three classes: simplified techniques, mathematical-modeling and simulation, and physical-modeling and experimentation. Simplified techniques use "rules-of-thumb'' heuristics to provide insights for simple daylighting systems. Mathematical-modeling and simulation use complex numerical models to provide more detailed insights into system performance. Finally, physical-models can be instrumented and excited using artificial and natural light sources to provide performance insight into a daylighting system. Each class of techniques, broadly speaking however, has advantages and disadvantages with respect to the cost of execution (e.g. money, time, expertise) and the fidelity of the provided insight into the performance of the daylighting system. This varying tradeoff of cost and insight between the techniques determines which techniques are employed for which projects. Daylighting systems with CFS components, however, when considered for simulation with respect to these traditional technique classes, defy high fidelity analysis. Simplified techniques are clearly not applicable. Mathematical-models must have great complexity in order to capture the non-specular transmission accurately, which greatly limit their applicability. This leaves physical modeling, the most costly, as the preferred method for CFS. While mathematical-modeling and simulation methods do exist, they are in general costly and and still approximations of the underlying CFS behavior. Meaning in fact, measurements of CFSs are currently the only practical method to capture the behavior of CFSs. Traditional measurements of CFSs transmission and reflection properties are conducted using an instrument called a goniophotometer and produce a measurement in the form of a Bidirectional Scatter Distribution Function (BSDF) based on the Klems Basis. This measurement must be executed for each possible state of the CFS, hence only a subset of the possible behaviors can be captured for CFSs with continuously varying configurations. In the current era of rapid prototyping (e.g. 3D printing) and automated control of buildings including daylighting systems, a new analysis technique is needed which can faithfully represent these CFSs which are being designed and constructed at an increasing rate. Hardware-in-the-loop modeling and simulation is a perfect fit to the current need of analyzing daylighting systems with CFSs. In the proposed hardware-in-the-loop modeling and simulation approach of this dissertation, physical-models of real CFSs are excited using either natural or artificial light. The exiting luminance distribution from these CFSs is measured and used as inputs to a Radiance mathematical-model of the interior of the space, which is proposed to be lit by the CFS containing daylighting system. Hence, the components of the total daylighting and building system which are not mathematically-modeled well, the CFS, are physically excited and measured, while the components which are modeled properly, namely the interior building space, are mathematically-modeled. In order to excite and measure CFSs behavior, a novel parallel goniophotometer, referred to as the CUBE 2.0, is developed in this dissertation. The CUBE 2.0 measures the input illuminance distribution and the output luminance distribution with respect to a CFS under test. Further, the process is fully automated allowing for deployable experiments on proposed building sites, as well as in laboratory based experiments. In this dissertation, three CFSs, two commercially available and one novel--Twitchell's Textilene 80 Black, Twitchell's Shade View Ebony, and Translucent Concrete Panels (TCP)--are simulated on the CUBE 2.0 system for daylong deployments at one minute time steps. These CFSs are assumed to be placed in the glazing space within the Reference Office Radiance model, for which horizontal illuminance on a work plane of 0.8 m height is calculated for each time step. While Shade View Ebony and TCPs are unmeasured CFSs with respect to BSDF, Textilene 80 Black has been previously measured. As such a validation of the CUBE 2.0 using the goniophotometer measured BSDF is presented, with measurement errors of the horizontal illuminance between +3% and -10%. These error levels are considered to be valid within experimental daylighting investigations. Non-validated results are also presented in full for both Shade View Ebony as well as TCP. Concluding remarks and future directions for HWiL simulation close the dissertation.
Implementing a resident lifting system in an extended care hospital. Demonstrating cost-benefit.
Spiegel, Jerry; Yassi, Analee; Ronald, Lisa A; Tate, Robert B; Hacking, Penny; Colby, Teresa
2002-03-01
1. Implemeting mechanical resident lifting equipment in an extended care facility produced a payback from direct savings alone within 4 years. Payback occurred more quickly when the effect of indirect savings or the trend to rising compensation costs was considered. 2. Combining the observations of the occupational health nurses related to staff well being with relevant cost-benefit data is useful in influencing decision makers and in securing funding for prevention measures. 3. Clear identification of a viewpoint is an important part of an economic evaluation and cost-benefit analysis.
Modelling Complex Fenestration Systems using physical and virtual models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thanachareonkit, Anothai; Scartezzini, Jean-Louis
2010-04-15
Physical or virtual models are commonly used to visualize the conceptual ideas of architects, lighting designers and researchers; they are also employed to assess the daylighting performance of buildings, particularly in cases where Complex Fenestration Systems (CFS) are considered. Recent studies have however revealed a general tendency of physical models to over-estimate this performance, compared to those of real buildings; these discrepancies can be attributed to several reasons. In order to identify the main error sources, a series of comparisons in-between a real building (a single office room within a test module) and the corresponding physical and virtual models wasmore » undertaken. The physical model was placed in outdoor conditions, which were strictly identical to those of the real building, as well as underneath a scanning sky simulator. The virtual model simulations were carried out by way of the Radiance program using the GenSky function; an alternative evaluation method, named Partial Daylight Factor method (PDF method), was also employed with the physical model together with sky luminance distributions acquired by a digital sky scanner during the monitoring of the real building. The overall daylighting performance of physical and virtual models were assessed and compared. The causes of discrepancies between the daylighting performance of the real building and the models were analysed. The main identified sources of errors are the reproduction of building details, the CFS modelling and the mocking-up of the geometrical and photometrical properties. To study the impact of these errors on daylighting performance assessment, computer simulation models created using the Radiance program were also used to carry out a sensitivity analysis of modelling errors. The study of the models showed that large discrepancies can occur in daylighting performance assessment. In case of improper mocking-up of the glazing for instance, relative divergences of 25-40% can be found in different room locations, suggesting that more light is entering than actually monitored in the real building. All these discrepancies can however be reduced by making an effort to carefully mock up the geometry and photometry of the real building. A synthesis is presented in this article which can be used as guidelines for daylighting designers to avoid or estimate errors during CFS daylighting performance assessment. (author)« less
Energy Smart Schools--Applied Research, Field Testing, and Technology Integration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nebiat Solomon; Robin Vieira; William L. Manz
2004-12-01
The National Association of State Energy Officials (NASEO) in conjunction with the California Energy Commission, the Energy Center of Wisconsin, the Florida Solar Energy Center, the New York State Energy Research and Development Authority, and the Ohio Department of Development's Office of Energy Efficiency conducted a four-year, cost-share project with the U.S. Department of Energy (USDOE), Office of Energy Efficiency and Renewable Energy to focus on energy efficiency and high-performance technologies in our nation's schools. NASEO was the program lead for the MOU-State Schools Working group, established in conjunction with the USDOE Memorandum of Understanding process for collaboration among statemore » and federal energy research and demonstration offices and organizations. The MOU-State Schools Working Group included State Energy Offices and other state energy research organizations from all regions of the country. Through surveys and analyses, the Working Group determined the school-related energy priorities of the states and established a set of tasks to be accomplished, including the installation and evaluation of microturbines, advanced daylighting research, testing of schools and classrooms, and integrated school building technologies. The Energy Smart Schools project resulted in the adoption of advanced energy efficiency technologies in both the renovation of existing schools and building of new ones; the education of school administrators, architects, engineers, and manufacturers nationwide about the energy-saving, economic, and environmental benefits of energy efficiency technologies; and improved the learning environment for the nation's students through use of better temperature controls, improvements in air quality, and increased daylighting in classrooms. It also provided an opportunity for states to share and replicate successful projects to increase their energy efficiency while at the same time driving down their energy costs.« less
Bats on a Budget: Torpor-Assisted Migration Saves Time and Energy
McGuire, Liam P.; Jonasson, Kristin A.; Guglielmo, Christopher G.
2014-01-01
Bats and birds must balance time and energy budgets during migration. Migrating bats face similar physiological challenges to birds, but nocturnality creates special challenges for bats, such as a conflict between travelling and refueling, which many birds avoid by feeding in daylight and flying at night. As endothermic animals, bats and birds alike must expend substantial amounts of energy to maintain high body temperatures. For migratory birds refueling at stopovers, remaining euthermic during inactive periods reduces the net refuelling rate, thereby prolonging stopover duration and delaying subsequent movement. We hypothesized that bats could mitigate similar ambient-temperature dependent costs by using a torpor-assisted migration strategy. We studied silver-haired bats Lasionycteris noctivagans during autumn migration using a combination of respirometry and temperature-sensitive radiotelemetry to estimate energy costs incurred under ambient temperature conditions, and the energy that bats saved by using torpor during daytime roosting periods. All bats, regardless of sex, age, or body condition used torpor at stopover and saved up to 91% of the energy they would have expended to remain euthermic. Furthermore, bats modulated use of torpor depending on ambient temperature. By adjusting the time spent torpid, bats achieved a rate of energy expenditure independent of the ambient temperature encountered at stopover. By lowering body temperature during inactive periods, fuel stores are spared, reducing the need for refuelling. Optimal migration models consider trade-offs between time and energy. Heterothermy provides a physiological strategy that allows bats to conserve energy without paying a time penalty as they migrate. Although uncommon, some avian lineages are known to use heterothermy, and current theoretical models of migration may not be appropriate for these groups. We propose that thermoregulatory strategies should be an important consideration of future migration studies of both bats and birds. PMID:25551615
The Effects of Primary Light Sources on Worker Performance and Alertness
NASA Technical Reports Server (NTRS)
Wong, Lily; Caddick, Zachary; Kuriyagawa, Yukiyo; Flynn-Evans, Erin
2017-01-01
Traditional office buildings use a variety of primary light sources (e.g., LED/fluorescent lights). As interest in LEED certified office buildings increase and research has shown that enhanced lighting design improves human performance and alertness (Viola et al., 2008; Juslén & Tenner, 2005; Edwards & Torcellini, 2002), more office buildings are incorporating a daylighting design. We investigated the differences between employee performance and alertness in two different building types (daylight vs. artificial light). We hypothesized that employee performance and sleep duration would be improved in a building designed to increase exposure to natural daylight compared to traditional office settings.
Daylight exposure and the other predictors of burnout among nurses in a University Hospital.
Alimoglu, Mustafa Kemal; Donmez, Levent
2005-07-01
The purpose of the study was to investigate if daylight exposure in work setting could be placed among the predictors of job burnout. The sample was composed of 141 nurses who work in Akdeniz University Hospital in Antalya, Turkey. All participants were asked to complete a personal data collection form, the Maslach Burnout Inventory, the Work Related Strain Inventory and the Work Satisfaction Questionnaire to collect data about their burnout, work-related stress (WRS) and job satisfaction (JS) levels in addition to personal characteristics. Descriptive statistics, parametric and non-parametric tests and correlation analysis were used in statistical analyses. Daylight exposure showed no direct effect on burnout but it was indirectly effective via WRS and JS. Exposure to daylight at least 3h a day was found to cause less stress and higher satisfaction at work. Suffering from sleep disorders, younger age, job-related health problems and educational level were found to have total or partial direct effects on burnout. Night shifts may lead to burnout via work related strain and working in inpatient services and dissatisfaction with annual income may be effective via job dissatisfaction. This study confirmed some established predictors of burnout and provided data on an unexplored area. Daylight exposure may be effective on job burnout.
ERIC Educational Resources Information Center
Kennedy, Mike
2007-01-01
In recent years, more education administrators and designers have embraced the potential benefits of daylighting. They have been persuaded that using natural light to illuminate facilities enables schools and universities to conserve energy and provide a learning environment in which students perform better. For daylighting advocates, the…
Sanclemente, G; Mancilla, G A; Hernandez, G
2016-04-01
Daylight PDT (dPDT) is easy to use and does not require light equipment. Such therapy has been exhaustively proved to be successful in the treatment of actinic keratosis, but its use in skin photodamage remains unclear. To evaluate dPDT's efficacy in skin facial photodamage. This was a parallel-group double-blind, randomized placebo-controlled trial. Sixty participants with symmetric facial photodamage were allocated to topical methyl aminolevulinate (MAL) and daylight vs. matching placebo and daylight. Primary outcome was global photodamage improvement/failure 1 month after the third session. Secondary outcomes included: pain evaluation; specific photodamage severity scores; sun irradiance quantification and Skindex-29 scores. Adverse events were also investigated. Primary analysis included all randomized patients. All patients sun-exposed for 120min in 3 sessions. The risk of failure was lower in the MAL-dPDT group than in the placebo plus daylight group (RR: 0.18; 95% CI: 0.08-0.41). Mean solar irradiance (W/m(2)) during the first, second and third sessions was 480.82, 430.07 and 435.84, respectively. Items 5 and 14 of Skindex-29 in the MAL-dPDT group showed statistical significant differences. Two patients in the MAL-dPDT group had serious and non-serious events not directly related to the product. dPDT with MAL was un-painful, effective and safe for the treatment of facial photodamage. Herpes simplex prophylaxis should be considered before sessions. Copyright © 2015 AEDV. Published by Elsevier España, S.L.U. All rights reserved.
Zadeh, Rana Sagha; Shepley, Mardelle McCuskey; Williams, Gary; Chung, Susan Sung Eun
2014-01-01
To investigate the physiological and psychological effects of windows and daylight on registered nurses. To date, evidence has indicated that appropriate environmental lighting with characteristics similar to natural light can improve mood, alertness, and performance. The restorative effects of windows also have been documented. Hospital workspaces generally lack windows and daylight, and the impact of the lack of windows and daylight on healthcare employees' well being has not been thoroughly investigated. Data were collected using multiple methods with a quasi-experimental approach (i.e., biological measurements, behavioral mapping, and analysis of archival data) in an acute-care nursing unit with two wards that have similar environmental and organizational conditions, and similar patient populations and acuity, but different availability of windows in the nursing stations. Findings indicated that blood pressure (p < 0.0001) decreased and body temperature increased (p = 0.03). Blood oxygen saturation increased (p = 0.02), but the difference was clinically insignificant. Communication (p < 0.0001) and laughter (p = 0.03) both increased, and the subsidiary behavior indicators of sleepiness and deteriorated mood (p = 0.02) decreased. Heart rate (p = 0.07), caffeine intake (p = 0.3), self-reported sleepiness (p = 0.09), and the frequency of medication errors (p = 0.14) also decreased, but insignificantly. The findings support evidence from laboratory and field settings of the benefits of windows and daylight. A possible micro-restorative effect of windows and daylight may result in lowered blood pressure and increased oxygen saturation and a positive effect on circadian rhythms (as suggested by body temperature) and morning sleepiness. Critical care/intensive care, lighting, nursing, quality care, work environment.
Boubekri, Mohamed; Cheung, Ivy N.; Reid, Kathryn J.; Wang, Chia-Hui; Zee, Phyllis C.
2014-01-01
Study Objective: This research examined the impact of daylight exposure on the health of office workers from the perspective of subjective well-being and sleep quality as well as actigraphy measures of light exposure, activity, and sleep-wake patterns. Methods: Participants (N = 49) included 27 workers working in windowless environments and 22 comparable workers in workplaces with significantly more daylight. Windowless environment is defined as one without any windows or one where workstations were far away from windows and without any exposure to daylight. Well-being of the office workers was measured by Short Form-36 (SF-36), while sleep quality was measured by Pittsburgh Sleep Quality Index (PSQI). In addition, a subset of participants (N = 21; 10 workers in windowless environments and 11 workers in workplaces with windows) had actigraphy recordings to measure light exposure, activity, and sleep-wake patterns. Results: Workers in windowless environments reported poorer scores than their counterparts on two SF-36 dimensions—role limitation due to physical problems and vitality—as well as poorer overall sleep quality from the global PSQI score and the sleep disturbances component of the PSQI. Compared to the group without windows, workers with windows at the workplace had more light exposure during the workweek, a trend toward more physical activity, and longer sleep duration as measured by actigraphy. Conclusions: We suggest that architectural design of office environments should place more emphasis on sufficient daylight exposure of the workers in order to promote office workers' health and well-being. Citation: Boubekri M, Cheung IN, Reid KJ, Wang CH, Zee PC. Impact of windows and daylight exposure on overall health and sleep quality of office workers: a case-control pilot study. J Clin Sleep Med 2014;10(6):603-611. PMID:24932139
HORIZONTAL HYBRID SOLAR LIGHT PIPE: AN INTEGRATED SYSTEM OF DAYLIGHT AND ELECTRIC LIGHT
This project will test the feasibility of an advanced energy efficient perimeter lighting system that integrates daylighting, electric lighting, and lighting controls to reduce electricity consumption. The system is designed to provide adequate illuminance levels in deep-floor...
NASA Astrophysics Data System (ADS)
Zagury, Frederic
2012-10-01
The color of the sky in day-time and at twilight is studied by means of spectroscopy, which provides an unambiguous way to understand and quantify why a sky is blue, pink, or red. The colors a daylight sky can take primarily owe to Rayleigh extinction and ozone absorption. Spectra of the sky illuminated by the sun can generally be represented by a generic analytical expression which involves the Rayleigh function R ≈ 1/λ^4 e(?a/λ^4), ozone absorption, and, to a lesser extend, aerosol extinction. This study is based on a representative sample of spectra selected from a few hundred observations taken in different places, times, and dates, with a portable fiber spectrometer.
Reduction of lighting energy consumption in office buildings through improved daylight design
NASA Astrophysics Data System (ADS)
Papadouri, Maria Violeta Prado
This study aims to investigate the lighting energy consumption in office buildings and the options for its reduction. One way to reduce lighting energy consumption is by improving the daylight design. A better use of daylight in buildings might be an outcome from the effort made in different directions. Like the improvement of a building's fabric and layout, the materials, even the furniture in a space influences the daylight quality considerably. Also very important role in lighting energy consumption has the development of more efficient lighting technology like the electric lighting control systems, such as photo sensors and occupancy sensors. Both systems are responsible so that the electric light is not used without reason. As the focusing area of this study, is to find ways to improve the daylight use in buildings, a consequent question is which are the methods provided in order to achieve this The accuracy of the methodology used is also an important issue in order to achieve reliable results. The methodology applied in this study includes the analysis of a case study by taking field measurements and computer simulations. The first stage included gathering information about the lighting design of the building and monitoring the light levels, both from natural and from the electric lighting. The second stage involved testing with computer simulations, different parameters that were expected to improve the daylight exploitation of the specific area. The results of the field measurements showed that the main problems of the space were the low natural light levels and the poor daylight distribution. The annual electric lighting energy consumption, as it was calculated with the use of computer simulations, represented the annual energy consumption of a typical air-conditioned prestige office building (energy consumption guide 19, for energy use in offices, 2000). After several computer simulations, the results showed that initial design parameters of the building can affect the lighting energy consumption of the space significantly. On the other hand, relatively small changes, like changing the reflectance of the surfaces and the lighting control systems can make even more difference to the light quality of the space and the reduction of lighting energy consumption.
Wrist activity in a woman: daily, weekly, menstrual, lunar, annual cycles?
Binkley, S
1992-09-01
Wrist activity was monitored continuously for one year in a woman who went about her normal life. The year of data were analyzed for changes and rhythms--daily, weekly, menstrual, lunar, annual. For each day, average motions/5 minutes, activity onset, activity offset, alpha (duration of activity), and acrophase were measured. Periodograms and average daily wave forms were calculated. Well-defined, entrained, daily rest-activity cycles were observed throughout the year with periods close to 24 hours. There was weekend delay (0.7 hours) in onset, weekend decrease in alpha (1.0 hours), and weekend advance of acrophase (0.4 hours). Motions/5 minutes decreased 9%, onsets were 0.3 hours later, and alphas were 0.4 hours shorter on menstrual cycle days 8 through 18 which should have encompassed the time of ovulation. Lunar phase had no effect. Annual changes in onset (1.1 hours), offset (1.2 hours), and acrophase (1.1 hours) were attributed to the 1-hour change between standard and daylight savings time.
Wind power as an electrical energy source in Illinois
NASA Astrophysics Data System (ADS)
Wendland, W. M.
1982-03-01
A preliminary estimate of the total wind power available in Illinois was made using available historical data, and projections of cost savings due to the presence of wind-generated electricity were attempted. Wind data at 10 m height were considered from nine different sites in the state, with three years data nominally being included. Wind-speed frequency histograms were developed for day and night periods, using a power law function to extrapolate the 10 m readings to 20 m. Wind speeds over the whole state were found to average over 8 mph, the cut-in point for most wind turbines, for from 40-63% of the time. A maximum of 75% run-time was determined for daylight hours in April-May. A reference 1.8 kW windpowered generator was used in annual demand projections for a reference one family home, using the frequency histograms. The small generator was projected to fulfill from 25-53% of the annual load, and, based on various cost assumptions, exhibited paybacks taking from 14-27 yr.
Investigation of nocturnal oviposition by necrophilous flies in central Texas.
Baldridge, Robert S; Wallace, Susan G; Kirkpatrick, Ryan
2006-01-01
The need to accurately estimate the postmortem interval (PMI) has prompted research into factors affecting fly oviposition (i.e., oviposition and/or larviposition) on a corpse. Research efforts have focused on whether or not diurnally active flies oviposit during nighttime hours. This study reports that nocturnal oviposition (defined as occurring between 2100-0600 h CDST (Central Daylight Savings Time)) did not occur on freshly killed white rats or mice, on beef (fresh or aged up to 48 h), on freshly thawed pigs, nor, usually, on thawed pigs that were aged for up to 48 h. Limited oviposition did occur between 2100 and 2120 h on one bloated pig at a lighted rural site. Necrophilous flies were present and active at lighted and dark sites (urban and rural) before and immediately after sunset, but fly activity on the bait ceased within 50 min postsunset and did not resume until after 0600 h. These observations support other studies reporting that diurnally active flies do not oviposit during the nighttime.
Energy and economic efficiency alternatives for electric lighting in commercial buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robbins, C L; Hunter, K C; Carlisle, N
1985-10-01
This report investigates current efficient alternatives for replacing or supplementing electric lighting systems in commercial buildings. Criteria for establishing the economic attractiveness of various lighting alternatives are defined and the effect of future changes in building lighting on utility capacity. The report focuses on the energy savings potential, economic efficiency, and energy demand reduction of three categories of lighting alternatives: (1) use of a renewable resource (daylighting) to replace or supplement electric lighting; (2) use of task/ambient lighting in lieu of overhead task lighting; and (3) equipment changes to improve lighting energy efficiency. The results indicate that all three categoriesmore » offer opportunities to reduce lighting energy use in commercial buildings. Further, reducing lighting energy causes a reduction in cooling energy use and cooling capacity while increasing heating energy use. It does not typically increase heating capacity because the use of lighting in the building does not offset the need for peak heating at night.« less
ERIC Educational Resources Information Center
Willi, John G.
2003-01-01
Describes how one elementary school was designed to be a flexible, innovative campus that connects learning and the learning environment. The celebration of nature is carried out in many ways within the building. Students are exposed to great vistas from every interior location. Daylighting is infused throughout the school to reinforce the desire…
Field Commissioning of a Daylight-Dimming Lighting System.
ERIC Educational Resources Information Center
Floyd, David B.; Parker, Danny S.
A Florida elementary school cafeteria, retrofitted with a fluorescent lighting system that dims in response to available daylight, was evaluated through real time measurement of lighting and air conditioning power, work plane illumination, and interior/exterior site conditions. The new system produced a 27 percent reduction in lighting power due…
75 FR 36089 - Payment System Risk Policy; Daylight Overdraft Posting Rules
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-24
... and includes only Accounts Receivable Entry (ARC), Back Office Conversion Entry (BOC), Point-of... account balance and daylight overdraft balance in Account Management Information (AMI), which is a service... under the authority delegated to the Board by the Office of Management and Budget. No collections of...
78 FR 64026 - Investigative Hearing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-25
... Investigative Hearing. On Friday, May 17, 2013, at 6:01 p.m. eastern daylight time, eastbound Metro-North... $18.5 million. On Tuesday, May 28, 2013, at 11:57 a.m. eastern daylight time, Metro-North Railroad...; and Metro-North's organizational safety culture. Parties to the hearing include the Federal Railroad...
Gadler, Fredrik; Ding, Yao; Verin, Nathalie; Bergius, Martin; Miller, Jeffrey D; Lenhart, Gregory M; Russell, Mason W
2016-01-01
The objective of this study was to quantify the impact that longer battery life of cardiac resynchronization therapy defibrillator (CRT-D) devices has on reducing the number of device replacements and associated costs of these replacements from a Swedish health care system perspective. An economic model based on real-world published data was developed to estimate cost savings and avoided device replacements for CRT-Ds with longer battery life compared with devices with industry-standard battery life expectancy. Base-case comparisons were performed among CRT-Ds of three manufacturers - Boston Scientific Corporation, St. Jude Medical, and Medtronic - over a 6-year time horizon, as per the available clinical data. As a sensitivity analysis, we evaluated CRT-Ds as well as single-chamber implantable cardioverter defibrillator (ICD-VR) and dual-chamber implantable cardioverter defibrillator (ICD-DR) devices over a longer 10-year period. All costs were in 2015 Swedish Krona (SEK) discounted at 3% per annum. Base-case analysis results show that up to 603 replacements and up to SEK 60.4 million cumulative-associated costs could be avoided over 6 years by using devices with extended battery life. The pattern of savings over time suggests that savings are modest initially but increase rapidly beginning in the third year of follow-up with each year's cumulative savings two to three times the previous year. Evaluating CRT-D, ICD-VR, and ICD-DR devices together over a longer 10-year period, the sensitivity analysis showed 2,820 fewer replacement procedures and associated cost savings of SEK 249.3 million for all defibrillators with extended battery life. Extended battery life is likely to reduce device replacements and associated complications and costs, which may result in important cost savings and a more efficient use of health care resources as well as a better quality of life for heart failure patients in Sweden.
Effective Energy Simulation and Optimal Design of Side-lit Buildings with Venetian Blinds
NASA Astrophysics Data System (ADS)
Cheng, Tian
Venetian blinds are popularly used in buildings to control the amount of incoming daylight for improving visual comfort and reducing heat gains in air-conditioning systems. Studies have shown that the proper design and operation of window systems could result in significant energy savings in both lighting and cooling. However, there is no convenient computer tool that allows effective and efficient optimization of the envelope of side-lit buildings with blinds now. Three computer tools, Adeline, DOE2 and EnergyPlus widely used for the above-mentioned purpose have been experimentally examined in this study. Results indicate that the two former tools give unacceptable accuracy due to unrealistic assumptions adopted while the last one may generate large errors in certain conditions. Moreover, current computer tools have to conduct hourly energy simulations, which are not necessary for life-cycle energy analysis and optimal design, to provide annual cooling loads. This is not computationally efficient, particularly not suitable for optimal designing a building at initial stage because the impacts of many design variations and optional features have to be evaluated. A methodology is therefore developed for efficient and effective thermal and daylighting simulations and optimal design of buildings with blinds. Based on geometric optics and radiosity method, a mathematical model is developed to reasonably simulate the daylighting behaviors of venetian blinds. Indoor illuminance at any reference point can be directly and efficiently computed. They have been validated with both experiments and simulations with Radiance. Validation results show that indoor illuminances computed by the new models agree well with the measured data, and the accuracy provided by them is equivalent to that of Radiance. The computational efficiency of the new models is much higher than that of Radiance as well as EnergyPlus. Two new methods are developed for the thermal simulation of buildings. A fast Fourier transform (FFT) method is presented to avoid the root-searching process in the inverse Laplace transform of multilayered walls. Generalized explicit FFT formulae for calculating the discrete Fourier transform (DFT) are developed for the first time. They can largely facilitate the implementation of FFT. The new method also provides a basis for generating the symbolic response factors. Validation simulations show that it can generate the response factors as accurate as the analytical solutions. The second method is for direct estimation of annual or seasonal cooling loads without the need for tedious hourly energy simulations. It is validated by hourly simulation results with DOE2. Then symbolic long-term cooling load can be created by combining the two methods with thermal network analysis. The symbolic long-term cooling load can keep the design parameters of interest as symbols, which is particularly useful for the optimal design and sensitivity analysis. The methodology is applied to an office building in Hong Kong for the optimal design of building envelope. Design variables such as window-to-wall ratio, building orientation, and glazing optical and thermal properties are included in the study. Results show that the selected design values could significantly impact the energy performance of windows, and the optimal design of side-lit buildings could greatly enhance energy savings. The application example also demonstrates that the developed methodology significantly facilitates the optimal building design and sensitivity analysis, and leads to high computational efficiency.
Colour Mixing Based on Daylight
ERIC Educational Resources Information Center
Meyn, Jan-Peter
2008-01-01
Colour science is based on the sensation of monochromatic light. In contrast to that, surface colours are caused by reflection of wide sections of the daylight spectrum. Non-spectral colours like magenta and purple appear homologous to colours with spectral hue, if the approach of mixing monochromatic light is abandoned. It is shown that a large…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holder, L.M. III; Holder, L.M. IV
1999-07-01
The project was designed by the Overland Partners Architectural Firm for Riverbend Church of Austin as an Auditorium for Sunday Services and a venue for special theatrical presentations for the church and the community as well. It is an amphitheater on a hillside overlooking the Colorado River Valley. The amphitheater was selected as the building form to keep the audience closer to the speaker. A 175 ft wide by 60 ft tall arched window was installed on the north face to allow the audience to see the panorama views of the tree covered hills on the other side of themore » valley in the Texas Hill Country. Although the design is quite effective in achieving the program goals, these characteristics make it difficult to achieve effective daylighting without glare for the audience and television cameras since both face the north glazing. The design team was faced with providing quality daylighting for the audience and television cameras from the wall behind the stage. Most television studios have carefully controlled lighting systems with the major lighting component from behind the cameras. Virtually all television facilities with daylight contributing to the production lighting are in a building with high shading coefficient glass producing illumination on all areas equally or almost all glass and daylighting from skylights and clearstories above. All television networks have requirements for control of the quality of the video images to parallel those conditions for the program to be aired.« less
Pearce, Bradley; Crichton, Stuart; Mackiewicz, Michal; Finlayson, Graham D; Hurlbert, Anya
2014-01-01
The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow) and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K), all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed.
Boubekri, Mohamed; Cheung, Ivy N; Reid, Kathryn J; Wang, Chia-Hui; Zee, Phyllis C
2014-06-15
This research examined the impact of daylight exposure on the health of office workers from the perspective of subjective well-being and sleep quality as well as actigraphy measures of light exposure, activity, and sleep-wake patterns. Participants (N = 49) included 27 workers working in windowless environments and 22 comparable workers in workplaces with significantly more daylight. Windowless environment is defined as one without any windows or one where workstations were far away from windows and without any exposure to daylight. Well-being of the office workers was measured by Short Form-36 (SF-36), while sleep quality was measured by Pittsburgh Sleep Quality Index (PSQI). In addition, a subset of participants (N = 21; 10 workers in windowless environments and 11 workers in workplaces with windows) had actigraphy recordings to measure light exposure, activity, and sleep-wake patterns. Workers in windowless environments reported poorer scores than their counterparts on two SF-36 dimensions--role limitation due to physical problems and vitality--as well as poorer overall sleep quality from the global PSQI score and the sleep disturbances component of the PSQI. Compared to the group without windows, workers with windows at the workplace had more light exposure during the workweek, a trend toward more physical activity, and longer sleep duration as measured by actigraphy. We suggest that architectural design of office environments should place more emphasis on sufficient daylight exposure of the workers in order to promote office workers' health and well-being.
Thunderstorm observations from Space Shuttle
NASA Technical Reports Server (NTRS)
Vonnegut, B.; Vaughan, O. H., Jr.; Brook, M.
1983-01-01
Results of the Nighttime/Daytime Optical Survey of Lightning (NOSL) experiments done on the STS-2 and STS-4 flights are covered. During these two flights of the Space Shuttle Columbia, the astronaut teams of J. Engle and R. Truly, and K. Mattingly II and H. Hartsfield took motion pictures of thunderstorms with a 16 mm cine camera. Film taken during daylight showed interesting thunderstorm cloud formations, where individual frames taken tens of seconds apart, when viewed as stereo pairs, provided information on the three-dimensional structure of the cloud systems. Film taken at night showed clouds illuminated by lightning with discharges that propagated horizontally at speeds of up to 10 to the 5th m/sec and extended for distances on the order of 60 km or more.
The Distant Sodium Tail of Mercury
NASA Technical Reports Server (NTRS)
Potter, A. E.; Killen, R. M.; Morgan, T. H.
2001-01-01
Models of the sodium atmosphere of Mercury predict the possible existence of a cornet-like sodium tail. Detection and mapping of the predicted sodium tail would provide quantitative data on the energy of the process that produces sodium atoms from the planetary surface. Previous efforts to detect the sodium tail by means of observations done during daylight hours have been only partially successful because scattered sunlight obscured the weak sodium emissions in the tail. However, at greatest eastern elongation around the March equinox in the northern hemisphere, Mercury can be seen as an evening star in astronomical twilight. At this time, the intensity of scattered sunlight is low enough that sodium emissions as low as 500 Rayleighs can be detected. Additional information is contained in the original extended abstract.
Possibilities of Architectural Lighting to Create New Style
NASA Astrophysics Data System (ADS)
Chudinova, V. G.; Bokova, O. R.
2017-11-01
The article presents the argumentation of the provision on the style-forming potential of the lighting design the sphere of which is interpreted in a wide range of genres. The area of the intersection of form-building technological and artistic aspects lies in the field of ecology which includes not only energy saving, but also the well-being of the human and the society. The theory and practice of designing the night-time image of architectural ensembles, buildings and landscapes develops much slower than the implementation of light solutions in the advertising industry. In most cases, the possibilities of lighting design are used only in the field of decorative lighting despite their huge aesthetic potential and rapidly improving technologies. The request for innovation and uniqueness usually arises on the basis of image and political ambitions of large corporations or for the positioning of powerful brands. The success of such projects becomes a driver for both creation and promotion of innovative solutions. However, in a broader scientific sense, not only the design of artificial light systems but also the optimization of the daylight usage falls into the sphere lighting design. The need for the new methods of architectural shaping is dictated by the need to introduce in the building of resource-saving lighting technologies, ecological infrastructure including alternative energy sources. The article gives the examples of different lighting design genres supplemented with illustrations. The conclusions concern the prospective directions and tasks of scientific research in the field of lighting design.
Energy Savings Forecast of Solid-State Lighting in General Illumination Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Penning, Julie; Stober, Kelsey; Taylor, Victor
2016-09-01
The DOE report, Energy Savings Forecast of Solid-State Lighting in General Illumination Applications, is a biannual report which models the adoption of LEDs in the U.S. general-lighting market, along with associated energy savings, based on the full potential DOE has determined to be technically feasible over time. This version of the report uses an updated 2016 U.S. lighting-market model that is more finely calibrated and granular than previous models, and extends the forecast period to 2035 from the 2030 limit that was used in previous editions.
Adapting Wireless Technology to Lighting Control and Environmental Sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dana Teasdale; Francis Rubinstein; David S. Watson
Although advanced lighting control systems offer significant energy savings, the high cost of retrofitting buildings with advanced lighting control systems is a barrier to adoption of this energy-saving technology. Wireless technology, however, offers a solution to mounting installation costs since it requires no additional wiring to implement. To demonstrate the feasibility of such a system, a prototype wirelessly-controlled advanced lighting system was designed and built. The system includes the following components: a wirelessly-controllable analog circuit module (ACM), a wirelessly-controllable electronic dimmable ballast, a T8 3-lamp fixture, an environmental multi-sensor, a current transducer, and control software. The ACM, dimmable ballast, multi-sensor,more » and current transducer were all integrated with SmartMesh{trademark} wireless mesh networking nodes, called motes, enabling wireless communication, sensor monitoring, and actuator control. Each mote-enabled device has a reliable communication path to the SmartMesh Manager, a single board computer that controls network functions and connects the wireless network to a PC running lighting control software. The ACM is capable of locally driving one or more standard 0-10 Volt electronic dimmable ballasts through relay control and a 0-10 Volt controllable output, in addition to 0-24 Volt and 0-10 Volt inputs. The mote-integrated electronic dimmable ballast is designed to drive a standard 3-lamp T8 light fixture. The environmental multisensor measures occupancy, light level and temperature. The current transducer is used to measure the power consumed by the fixture. Control software was developed to implement advanced lighting algorithms, including open and closed-loop daylight ramping, occupancy control, and demand response. Engineering prototypes of each component were fabricated and tested in a bench-scale system. Based on standard industry practices, a cost analysis was conducted. It is estimated that the installation cost of a wireless advanced lighting control system for a retrofit application is at least 20% lower than a comparable wired system for a typical 16,000 square-foot office building, with a payback period of less than 3 years. At 30% market penetration saturation, a cumulative 695 Billion kWh of energy could be saved through 2025, a cost savings of $52 Billion.« less
Re-Analysis Report: Daylighting in Schools, Additional Analysis. Tasks 2.2.1 through 2.2.5.
ERIC Educational Resources Information Center
Heschong, Lisa; Elzeyadi, Ihab; Knecht, Carey
This study expands and validates previous research that found a statistical correlation between the amount of daylight in elementary school classrooms and the performance of students on standardized math and reading tests. The researchers reanalyzed the 19971998 school year student performance data from the Capistrano Unified School District…
Effects of cardiothoracic physiotherapy on intrapulmonary shunt in abdominal surgical patients.
Ntoumenopoulos, George; Greenwood, Kenneth
1996-01-01
This study investigated the provision of additional evening physiotherapy on pulmonary complications and intrapulmonary shunt (Qs/Qt) after abdominal surgery. Thirty-one elderly patients received either daylight only or daylight plus evening physiotherapy for up to 48 hours. Physiotherapy included combinations of positioning, gravity assisted drainage, breathing exercises, manual techniques, coughing and airway suctioning. Measurements included Qs/Qt and post-operative pulmonary complications. While no significant difference in atelectasis was found, the post-operative Qs/Qt data averaged into six-hour time frames demonstrated significantly lower mean Qs/Qt for the daylight plus evening physiotherapy group between 18 and 24 hours post-surgery. Additional evening physiotherapy may reduce post-operative deterioration in gas exchange after major abdominal surgery.
12 CFR 561.12 - Consumer credit.
Code of Federal Regulations, 2010 CFR
2010-01-01
...; loans in the nature of overdraft protection; and credit extended in connection with credit cards. ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Consumer credit. 561.12 Section 561.12 Banks... AFFECTING ALL SAVINGS ASSOCIATIONS § 561.12 Consumer credit. The term consumer credit means credit extended...
Zhou, Minghua; Yu, Jiaguo
2008-04-15
A simple method for preparing highly daylight-induced photoactive nanocrystalline C,N,S-tridoped TiO2 powders was developed by a solid-phase reaction. The as-prepared TiO2 powders were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), UV-vis diffuse reflectance spectra, N2 adsorption-desorption measurements and transmission electron microscopy (TEM). The photocatalytic activity was evaluated by the photocatalytic oxidation of formaldehyde under daylight irradiation in air. The results show that daylight-induced photocatalytic activities of the as-prepared TiO2 powders were improved by C,N,S-tridoping. The C,N,S-tridoped TiO2 powders exhibited stronger absorption in the near UV and visible-light region with red shift in the band-gap transition. When the molar ratio of CS(NH2)2 to xerogel TiO2 powders (prepared by hydrolysis of Ti(OC4H9)4 in distilled water) (R) was kept in 3, the daylight-induced photocatalytic activities of the as-prepared C,N,S-tridoped TiO2 powders were about more than six times greater than that of Degussa P25 and un-doped TiO2 powders. The high activities of the C,N,S-tridoped TiO2 can be attributed to the results of the synergetic effects of strong absorption in the near UV and visible-light region, red shift in adsorption edge and two phase structures of un-doped TiO2 and C,N,S-tridoped TiO2.
NASA Astrophysics Data System (ADS)
Wadsworth, Adam J.
A method for passively detecting and imaging underwater targets using ambient noise as the sole source of illumination (named acoustic daylight) was successfully implemented in the form of the Acoustic Daylight Ocean Noise Imaging System (ADONIS). In a series of imaging experiments conducted in San Diego Bay, where the dominant source of high-frequency ambient noise is snapping shrimp, a large quantity of ambient noise intensity data was collected with the ADONIS (Epifanio, 1997). In a subset of the experimental data sets, fluctuations of time-averaged ambient noise intensity exhibited a diurnal pattern consistent with the increase in frequency of shrimp snapping near dawn and dusk. The same subset of experimental data is revisited here and the correlation time is estimated and analysed for sequences of ambient noise data several minutes in length, with the aim of detecting possible periodicities or other trends in the fluctuation of the shrimp-dominated ambient noise field. Using videos formed from sequences of acoustic daylight images along with other experimental information, candidate segments of static-configuration ADONIS raw ambient noise data were isolated. For each segment, the normalized intensity auto-correlation closely resembled the delta function, the auto-correlation of white noise. No intensity fluctuation patterns at timescales smaller than a few minutes were discernible, suggesting that the shrimp do not communicate, synchronise, or exhibit any periodicities in their snapping. Also presented here is a ADONIS-specific target recognition algorithm based on principal component analysis, along with basic experimental results using a database of acoustic daylight images.
Pearce, Bradley; Crichton, Stuart; Mackiewicz, Michal; Finlayson, Graham D.; Hurlbert, Anya
2014-01-01
The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow) and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K), all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed. PMID:24586299
11 CFR 100.19 - File, filed or filing (2 U.S.C. 434(a)).
Code of Federal Regulations, 2014 CFR
2014-01-01
... Time on the filing date, except that pre-election reports must have a postmark dated no later than 11:59 p.m. Eastern Standard/Daylight Time on the fifteenth day before the date of the election. (2... Standard/Daylight Time on the filing date. (d) 48-hour and 24-hour reports of independent expenditures—(1...
ERIC Educational Resources Information Center
Amasuomo, Japo Oweikeye Morto; Alio, Abigail Ngozi
2013-01-01
The study investigated daylight illumination in the school workshop as a determinant for effective students' task performance in workshop practice. 183 NCE Technical students in 300 Level which comprised of 73 and 112 students from Federal Colleges of Education (Technical), Asaba and Omoku, Nigeria respectively during the 2008/2009 academic…
Differences in geometry of pedestrian crashes in daylight and darkness.
Sullivan, John M; Flannagan, Michael J
2011-02-01
Previous studies have shown that increased risk in darkness is particularly great for pedestrian crashes, suggesting that attempts to improve headlighting should focus on factors that likely influence those crashes. The current analysis was designed to provide information about how details of pedestrian crashes may differ between daylight and darkness. All pedestrian crashes that occurred in daylight or dark conditions in Michigan during 2004 were analyzed in terms of the variables included in the State of Michigan crash database. Additional analysis of the narratives and diagrams in police accident reports was performed for a subset of 400 of those crashes-200 sampled from daylight and 200 sampled from darkness. Several differences were found that appear to be related to the characteristic asymmetry of low-beam headlamps, which (in the United States) distributes more light on the passenger's side than the driver's side of the vehicle. These results provide preliminary quantification of the how the photometric differences between the right and left sides of typical headlamps may affect pedestrian crash risk. The results suggest that efforts to provide supplemental forward vehicle lighting in turns may have safety benefits for pedestrians. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kriszbacher, Ildikó; Bódis, József; Boncz, Imre; Koppan, Agnes; Koppan, Miklós
2010-04-01
We investigated whether the time of sunrise and the number of daylight hours have an effect on the seasonality, or the daily rhythm of heart attack mortality. We analyzed retrospectively data of patients admitted to hospitals with the diagnosis of heart attack (n=32,329) and patients who deceased of a heart attack (n=5142) between January 1, 2004 and December 31, 2005 in Hungary. Heart attack mortality was highest during winter, while lowest number of events was recorded during summer . The daily peak of diurnality was between 6:00 am and 12:00 pm (33.77%). A positive correlation was found between the time of sunrise, time of sunset and the mortality caused by myocardial infarction (p<0,01). In the analysis of the number of daylight hours and the heart attack mortality we found a negative correlation (r=-0.105, p<0.05). No significant difference was found between sexes and different age-groups in heart attack mortality. Our data suggest, that the occurrence and the mortality of heart attack may be related to the time of sunrise and the number of daylight hours. Copyright 2008 Elsevier Ireland Ltd. All rights reserved.
High-power lightweight external-cavity quantum cascade lasers
NASA Astrophysics Data System (ADS)
Day, Timothy; Takeuchi, Eric B.; Weida, Miles; Arnone, David; Pushkarsky, Michael; Boyden, David; Caffey, David
2009-05-01
Commercially available quantum cascade gain media has been integrated with advanced coating and die attach technologies, mid-IR micro-optics and telecom-style assembly and packaging to yield cutting edge performance. When combined into Daylight's external-cavity quantum cascade laser (ECqcL) platform, multi-Watt output power has been obtained. Daylight will describe their most recent results obtained from this platform, including high cw power from compact hermetically sealed packages and narrow spectral linewidth devices. Fiber-coupling and direct amplitude modulation from such multi-Watt lasers will also be described. In addition, Daylight will present the most recent results from their compact, portable, battery-operated "thermal laser pointers" that are being used for illumination and aiming applications. When combined with thermal imaging technology, such devices provide significant benefits in contrast and identification.
Microbiologic contamination during dental radiographic film processing.
Stanczyk, D A; Paunovich, E D; Broome, J C; Fatone, M A
1993-07-01
This study investigated microbiologic contamination of an automatic dental radiograph processor and daylight loader during a week of simulated clinical use. Pure cultures of Candida albicans, Streptococcus pneumoniae, Staphylococcus aureus, or Klebsiella pneumoniae were used to contaminate 320 vinyl intraoral radiograph packets. Each end of the films was deliberately contaminated during opening. These films and 24 uncontaminated control films were processed. Daylight loader ports, inlet and outlet rollers, fixer and developer samples, and 12 processed films were cultured daily. To simulate a weekend, the processor sites were cultured during 72 hours of inactivity after the contaminated runs. The results showed that contamination of the processor and daylight loader occurred and remained even after 48 hours of inactivity. Films remained contaminated after processing. In addition, cross-contamination of films occurred in the processor.
Psychological Effect of Daylighting on Behavior
NASA Astrophysics Data System (ADS)
Oyama, Yoshie
In order to facilitate use of daylighting in architectural design, we tried to measure the suitability of luminous environment for various behavior, including not only visual work but also refreshing and rest. An experiment was conducted with 7 luminous conditions including daylighting. The suitability of a luminous environment was measured by asking the subjects to select suitable activities and unsuitable behaviors from a given list of possible activities. The result showed the selection of unsuitable behaviors was more useful than the selection of suitable behaviors. Furthermore, lighting installations offering a steady luminous environments, were not suitable for many behaviors including refreshing and rest. The luminous environments which were bright but had some fluctuation and some non-uniformity of brightness, obtained by use of direct sunlight, were judged to be suitable for negotiating, refreshing, and meeting.
Demonstration of a light-redirecting skylight system at the Palm Springs Chamber of Commerce
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, E.S.; Beltran, L.O.; Selkowitz, S.E.
1996-05-01
As part of a demonstration project to provide a comprehensive energy upgrade to a 294 m{sup 2} (3168 ft{sup 2}) commercial building, an advanced skylight design was developed using optical light control materials and geometry to provide daylight to two adjoining offices. The skylight system was developed using outdoor physical model tests and simulation tools Limited on-site measurements and occupant polls were conducted. Market issues were addressed. The skylight systems were found to improve lighting quality and to control excessive daylight illuminance levels compared to a conventional diffusing bubble skylight. Daylighting principles developed in earlier work for vertical glazing systemsmore » (light shelves and light pipes) were shown to be applicable in skylight designs at full-scale.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dyson, Anna
Intelligent Facades for High Performance Green Buildings: Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, we have undertaken a high-performance building- integrated combined-heat andmore » power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring on- site solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high- quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for active and passive benefits, along with the potential savings of avoiding transmission losses through direct current (DC) transfer to all buildings systems directly from the site of solar conversion, gives the system a compounded economic viability within the commercial and institutional building markets.« less
A thesis investigating the impact of energy related environmental factors on domestic window design
NASA Astrophysics Data System (ADS)
McEvoy, Michael Edward
In recent years the extent of glazing in houses has been tightly controlled by the Building Regulations in order to save energy. In addition guidelines derived from passive solar principles prescribe the distribution of domestic windows between elevations according to their orientation. This thesis studies the impact of these energy-related environmental factors on domestic window design. The first of these investigations determined the degree to which limitations on the area and arrangement of windows are significant in terms of daylighting. The experiments measured the effect that passive solar requirements and detailed aspects of window design have on the quality of daylighting in houses. The volume of background ventilation required for domestic accommodation has recently been increased. As a result, in a well-sealed construction, heat loss due to background ventilation becomes a larger part of the total heat loss and larger air movements become a potential cause of draughts. The ventilation experiment sought to establish the impact of these more onerous requirements on comfort within rooms. The third experiment combines these factors and asks the question: Could windows be actively involved in overcoming some of these difficulties by being used to preheat ventilation air in order to diminish the extent of heat loss and to alleviate the problem of cold draughts? Also by designing the window to reclaim heat from the room might it be possible to offset the window's thermal inadequacy? Through analysis of responses to a questionnaire and the use of optimisation techniques, scenarios were suggested for the future modification of windows in relation to energy and health expectations. The conclusions form a commentary on recent and future revisions to the Building Regulations and determine whether or not the Regulations facilitate the environmental engineering of windows as an active component of a building's whole environmental system.
Power Saving Control for Battery-Powered Portable WLAN APs
NASA Astrophysics Data System (ADS)
Ogawa, Masakatsu; Hiraguri, Takefumi
This paper proposes a power saving control function for battery-powered portable wireless LAN (WLAN) access points (APs) to extend the battery life. The IEEE802.11 standard does not support power saving control for APs. To enable a sleep state for an AP, the AP forces the stations (STAs) to refrain from transmitting frames using the network allocation vector (NAV) while the AP is sleeping. Thus the sleep state for the AP can be employed without causing frame loss at the STAs. Numerical analysis and computer simulation reveal that the newly proposed control technique conserves power compared to the conventional control.
Brown, Ameldia R; Coppola, Patricia; Giacona, Marian; Petriches, Anne; Stockwell, Mary Ann
2009-01-01
Health systems seeking responsible stewardship of community benefit dollars supporting Faith Community Nursing Networks require demonstration of positive measurable health outcomes. Faith Community Nurses (FCNs) answer the call for measurable outcomes by documenting cost savings and cost avoidances to families, communities, and health systems associated with their interventions. Using a spreadsheet tool based on Medicare reimbursements and diagnostic-related groupings, 3 networks of FCNs have together shown more than 600 000 (for calendar year 2008) healthcare dollars saved by avoidance of unnecessary acute care visits and extended care placements. The cost-benefit ratio of support dollars to cost savings and cost avoidance demonstrates that support of FCNs is good stewardship of community benefit dollars.
Advanced Lighting Controls for Reducing Energy use and Cost in DoD Installations
2013-05-01
OccuSwitch Wireless is a room-based lighting control system employing dimmable light sources, occupancy and daylight sensors , wireless interconnection...combination of wireless and wired control solution for building-wide networked system that maximizes the use of daylight while improving visual...architecture of Hybrid ILDC. Architecture: The system features wireless connectivity among sensors and actuators within a zone and exploits wired
NASA Astrophysics Data System (ADS)
Elayeb, O. K.; Alghoul, M. A.; Sopian, K.; Khrita, N. G.
2017-11-01
Despite Double skin façade (DSF) buildings are widely deployed worldwide, daylighting strategy is not commonly incorporated in these buildings compare to other strategies. Therefore, further theoretical and experimental studies would lead to adopting daylighting strategy in DSF office buildings. The aim of this study is to investigate the daylighting performance of office building at different design parameters of box window DSF using different glazing types under sub interval of intermediate sky conditions (20-40) klux using the (IES VE) simulation tool from Integrated Environmental Solutions - Virtual Environment. The implemented design parameters are window wall ratio (WWR) of internal façade (10-100) %, cavity depth (CD) of DSF (1-2.5) m and different glazing types. The glazing types were selected from the list available in the (IES VE) simulation tool. After series of evaluations, bronze tinted coating (STOPSOL) is implemented for the exterior façade while clear float, clear reflective coating (STOPSOL), grey and brown tinted coating (Anti-sun float) and blue coating tinted (SUNCOOL float) are implemented for the interior façade. In this paper, several evaluation parameters are used to quantify the optimum design parameters that would balance the daylighting requirements of a box window DSF office versus sky conditions range (20-40) klux. The optimum design parameters of DSF office building obtained under different glazing types are highlighted as follows. When using bronze tinted coating (STOPSOL) for the exterior façade, the glazing types of interior façade that showed superior daylighting performance of DSF office at (CD of 1.0m with WWR of 70%), (CD of 1.5m with WWR of 70%), (CD of 2.0m with WWR of 70%) and (CD of 2.0m with WWR of 70%) are grey tinted coating (Anti-sun float), clear reflective coating (STOPSOL), brown tinted coating (Anti-sun float), and clear float glazing respectively. Blue Coating tinted (SUNCOOL float) of interior façade glazing failed to meet outstanding daylighting performance at any cavity depth.
Essence of Daylight in the Cistercian Monastic Church of S. Bento de Cástris, Évora, Portugal
NASA Astrophysics Data System (ADS)
Martins, Ana M. T.; Carlos, Jorge S.
2017-10-01
Natural light in the Cistercian churches is closely linked not only with the liturgical requirements at the “officium” but also with the canonical hours based on the "ora et labora" dictated by the Rule of St. Benedict. The Cistercian architecture, in its beginnings (12th century forward) is characterized by austerity, simplicity and the play of light and shadow that gives value to the monastic architectural space itself, making it perfect for a contemplative experience. In the Cistercian Monastery the church is the central piece of the monastic building. Nave, transept and apse are the main architectural components to which is added the choir. This paper contextualizes the importance and close connections of natural light, within the Cistercian Monasteries architecture. Thus the essence of daylight is analysed within the Church of the Monastery of S. Bento de Cástris, in Évora, Portugal. This former Monastery (13th - 19th centuries) includes the church, at the south-eastern corner which has not only a high choir, but also a low lateral choir (within the presbytery). Its unchanged exterior walls are made of solid masonry. Although the function of the walls is primarily structural, the windows allow the daylight to penetrate the space of the church. The church has two external façades facing northeast and southeast. The combined orientation effect of the church’s main axis and the sun trajectory determines how the sunlight reaches the interior of this architectural structure. This study presents the qualitative and quantitative analysis of the luminous environment in the church of S. Bento de Cástris, being the first based on the authors’ perception of the effect of the daylight within the different areas of the enclosed space. The appreciation of the spatial experiences was supported by quantitative daylight simulations that were conducted in selected areas within the space. With this paper is intended to contribute to the debate about the specificity of daylight, in the context of Cistercian architecture.
Aging influence on sensing properties of porous silica films sensitized toward ammonia
NASA Astrophysics Data System (ADS)
Tyszkiewicz, Cuma; Rogoziński, Roman
2015-12-01
The sol-gel technology allows preparation of thin silica films ranging in porosity from dense to highly porous. These films can function as a matrix binding molecules of the pH-sensitive dyes and can be utilized as the sensitive films for intensity based planar evanescent wave chemical sensors. Sensitive properties of these dyes decreases in time due to aging processes. We report characterization of weakening of sensing properties of highly porous silica films doped with the bromocresole purple (BCP). In the presence of the gaseous ammonia, the absorption band (AB) of protonated BCP centered at λ=430 nm, is shifted toward λ=591 nm due to deprotonation, resulting in the increase of sensitive films absorption in the range of wavelengths of shifted AB. Two sets of films were investigated. Films from the first one were cyclically exposed to the ammonia and stored isolated from the daylight. Films from the second set weren't exposed to the ammonia and were stored in a staining jar exposed to the daylight. A depth of the AB at λ=430 nm was measured using a spectrophotometer. A sensitivity of the films toward ammonia was measured using LED emitting at center wavelength λ=610 nm. As was shown, the sensitivity of these films exposed to the ammonia diluted in dry air, and isolated from the daylight, decreases in time exponentially. The magnitude of that decrease monotonically depends on the ammonia concentration. It was also shown that the daylight causes quick aging of films not exposed to the ammonia. A depth of the AB centered at λ=430 nm relatively quickly decreased when compared with films isolated from the daylight and exposed to the ammonia.
Hatamleh, Muhanad M; Watts, David C
2010-07-01
The purpose of this study was to test the effect of different periods of accelerated artificial daylight aging on bond strength of glass fiber bundles embedded into maxillofacial silicone elastomer and on bending strength of the glass fiber bundles. Forty specimens were fabricated by embedding resin-impregnated fiber bundles (1.5-mm diameter, 20-mm long) into maxillofacial silicone elastomer. Specimens were randomly allocated into four groups, and each group was subjected to different periods of accelerated daylight aging as follows (in hours); 0, 200, 400, and 600. The aging cycle included continuous exposure to quartz-filtered visible daylight (irradiance 760 W/m(2)) under an alternating weathering cycle (wet for 18 minutes, dry for 102 minutes). Pull-out tests were performed to evaluate bond strength between fiber bundles and silicone using a universal testing machine at 1 mm/min crosshead speed. Also a three-point bending test was performed to evaluate bending strength of the fiber bundles. One-way ANOVA and Bonferroni post hoc tests were carried out to detect statistical significance (p < 0.05). Mean (SD) values of maximum pull-out forces (in N) for groups 1 to 4 were: 13.63 (7.45), 19.67 (1.37), 13.58 (2.61), and 10.37 (2.52). Group 2 exhibited the highest pull-out force that was statistically significant when compared to the other groups. Maximum bending strengths of fiber bundles were in the range of 917.72 MPa to 1124.06 MPa. Bending strength significantly increased after 200 and 400 hours of aging only. After 200 hours of exposure to artificial daylight and moisture conditions, bond strength between glass fibers and heat-cured silicones is optimal, and the bending strength of the glass fiber bundles is enhanced.
Daylighting and shuttering: RIB system mechanical design and preliminary performance data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kinney, L.; Reynolds, D.
1983-12-01
The Reflective, Insulating Blind (RIB) system is a flexible, user-controlled daylighting device which also has direct thermal advantages: it can reject a considerable portion of summer sun while still retaining an adequate daylighting function; and it functions as moveable insulation to significantly decrease thermal losses through fenestration during evening hours. The conceptual design of the RIB system was accomplished by Barnes and Shapira at the Oak Ridge National Laboratory (ORNL). Mechanical design and prototype fabrication was accomplished by the authors and 29 systems were installed immediately inside existing south-facing windows of an energy-efficient office and dormitory at ORNL. The buildingmore » is a heavily-instrumented, passively-solar-heated structure for which reliable performance data was gathered and analyzed before the addition of RIB systems, thus facilitating the interpretation of ''after RIB'' performance data.« less
NASA Astrophysics Data System (ADS)
Komerska, Anna; Ksionek, Dariusz; Rosiński, Marian
2017-11-01
This article presents results of the energy performance of an external translucent shading component integrated with a phase change material. A proposed technology is able to accumulate considerable amounts of energy in the latent heat by absorbing solar energy. Due to selective optical properties, much of the visible light is still transmitted through the facade. Experimental measurements were carried out in a laboratory set-up - testing thermal chamber, located in the Faculty of Building Services, Hydro and Environmental Engineering at Warsaw University of Technology. The main result of the experimental study was the evaluation of the average solar transmittance in the whole measured spectrum, as well as in the infrared and visible light. Since the shift in optical properties was observed when the material was undergoing a phase transition, the average spectral transmittances were measured for different states of matter of the PCM material. The tested shutter showed abilities to reduce and modulate daylight and solar heat gains in the indoor environment, which could contribute to considerable energy savings.
Sunlight Responsive Thermochromic Window System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Millett, F,A; Byker,H, J
2006-10-27
Pleotint has embarked on a novel approach with our Sunlight Responsive Thermochromic, SRT™, windows. We are integrating dynamic sunlight control, high insulation values and low solar heat gain together in a high performance window. The Pleotint SRT window is dynamic because it reversibly changes light transmission based on thermochromics activated directly by the heating effect of sunlight. We can achieve a window package with low solar heat gain coefficient (SHGC), a low U value and high insulation. At the same time our windows provide good daylighting. Our innovative window design offers architects and building designers the opportunity to choose theirmore » desired energy performance, excellent sound reduction, external pane can be self-cleaning, or a resistance to wind load, blasts, bullets or hurricanes. SRT windows would provide energy savings that are estimated at up to 30% over traditional window systems. Glass fabricators will be able to use existing equipment to make the SRT window while adding value and flexibility to the basic design. Glazing installers will have the ability to fit the windows with traditional methods without wires, power supplies and controllers. SRT windows can be retrofit into existing buildings,« less
Human daily rhythms measured for one year.
Binkley, S; Tome, M B; Crawford, D; Mosher, K
1990-08-01
Four human subjects recorded their wake-up and to-sleep times for one year each. The data were plotted to display individual circadian rhythms and the data were analyzed statistically. First, individuals had characteristic patterns in which visible changes in the patterns were observed mainly when time zones were changed because of travel. Second, the months with the latest wake-up and latest to-sleep times concentrated around the winter solstice; the months with the earliest wake-up and earliest to-sleep times concentrated around the fall equinox. Third, new moon versus full moon days were not different. Fourth, one-hour changes between standard and daylight savings time in the USA were reflected by near one-hour changes in two subjects, but not in a third. Fifth, weekend delays in wake-up time (0.8-1.6 hours), weekend delays in to-sleep time (0.1-0.5 hours), and shorter weekend awake time (0.8-1.3 hours) were observed. Sixth, throughout the year, wake-up times were close to the time of sunrise, but to-sleep times were several hours past sunset.
Phosphor chessboard packaging for white LEDs in high efficiency and high color performance
NASA Astrophysics Data System (ADS)
Nguyen, Quang-Khoi; Chang, Yu-Yu; Lu, Chun-Yan; Yang, Tsung-Hsun; Chung, Te-Yuan; Sun, Ching-Cherng
2016-09-01
We performed the simulation of white LEDs packaging with different chessboard structures of white light converting phosphor layer covered on GaN die chip. Three different types of chessboard structures are called type 1, type 2 and type 3, respectively. The result of investigation according to the phosphor thickness show the increasing of thickness of phosphor layer are, the decreasing of output blue light power are. Meanwhile, the changes of yellow light are neglect. Type 3 shows highest packaging efficiency of 74.3 % compares with packaging efficiency of type 2 and type 1 (72.5 % and 71.3 %, respectively). Type 3 also shows the most effect of forward light. Attention that the type 3 chessboard structure gets packaging efficiency of 74.3 % at color temperature of daylight as well as high saving of phosphor amount. The color temperatures of three types of chessboard structure are higher than 5000 K, so they are suitable for lighting purpose. The angular correlate color temperature deviation (ACCTD) of type 1, type 2 and type 3 are 6500K, 11500K and 17000K, respectively.
Hurricane Isaac by Night [annotated
2017-12-08
NASA image acquired August 29, 2012 1:57 a.m EDT Hurricane Isaac lit up by moonlight as it spins over the city of New Orleans, La. at 1:57 am central daylight savings time the morning of August 29, 2012. The Suomi National Polar-orbiting Partnership (NPP) satellite captured these images with its Visible Infrared Imaging Radiometer Suite (VIIRS). The "day-night band" of VIIRS detects light in a range of wavelengths from green to near-infrared and uses light intensification to enable the detection of dim signals. Suomi NPP is the result of a partnership between NASA, the National Oceanic and Atmospheric Administration and the Department of Defense. Image Credit: NASA/NOAA, Earth Observatory NASA Earth Observatory image by Jesse Allen and Robert Simmon, using VIIRS Day Night Band data. Credit: NASA Earth Observatory NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Tips for daylighting with windows
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, Alastair; Selkowitz, Stephen
2013-10-01
These guidelines provide an integrated approach to the cost-effective design of perimeter zones in new commercial buildings and existing building retrofits. They function as a quick reference for building designers, through a set of easy steps and rules-of-thumb, emphasizing “how-to” practical details. References are given to more detailed sources of information, should the reader wish to go further. The design method used in this document emphasizes that building decisions should be made within the context of the whole building as a single functioning system rather than as an assembly of distinct parts. This integrated design approach looks at the ramificationsmore » of each individual system decision on the whole building. For example, the decision on glazing selection will have an effect on lighting, mechanical systems, and interior design. Therefore, the entire design team should participate and influence this glazing decision—which typically rests with the architect alone. The benefit of an integrated design approach is a greater chance of success towards long-term comfort and sustained energy savings in the building.« less
Cost of lifetime immunosuppression coverage for kidney transplant recipients.
Page, Timothy F; Woodward, Robert S
2008-01-01
On January 1, 2000, Medicare extended the coverage of immunosuppression medications from 3 years to life for elderly and disabled kidney transplant recipients. This research estimates the impact of extending this lifetime coverage to all kidney transplant recipients on Medicare's cash flows. The study finds that extending coverage to all kidney transplant recipients would have increased Medicare's net cash outflows if the coverage were extended for patients of all income levels. There is evidence that extending coverage to only patients in the lowest income quartile could have resulted in a net cost savings to Medicare.
Review of Radio Frequency Photonics Basics
2017-09-06
essentially from “Direct Current to Daylight,” allowing use for high frequency applications. This report covers some needs and advantages of radio...operate essentially from “Direct Current (DC) to Daylight,” allowing use for high frequency applications. The following sections of this report cover...spectrum leaving higher frequencies open for new uses. Frequency bands from 600 MHz to 5 GHz are used for commercial communications in the US. The future
A tuneable approach to uniform light distribution for artificial daylight photodynamic therapy.
O'Mahoney, Paul; Haigh, Neil; Wood, Kenny; Brown, C Tom A; Ibbotson, Sally; Eadie, Ewan
2018-06-16
Implementation of daylight photodynamic therapy (dPDT) is somewhat limited by variable weather conditions. Light sources have been employed to provide artificial dPDT indoors, with low irradiances and longer treatment times. Uniform light distribution across the target area is key to ensuring effective treatment, particularly for large areas. A novel light source is developed with tuneable direction of light emission in order to meet this challenge. Wavelength composition of the novel light source is controlled such that the protoporphyrin-IX (PpIX) weighed spectra of both the light source and daylight match. The uniformity of the light source is characterised on a flat surface, a model head and a model leg. For context, a typical conventional PDT light source is also characterised. Additionally, the wavelength uniformity across the treatment site is characterised. The PpIX-weighted spectrum of the novel light source matches with PpIX-weighted daylight spectrum, with irradiance values within the bounds for effective dPDT. By tuning the direction of light emission, improvements are seen in the uniformity across large anatomical surfaces. Wavelength uniformity is discussed. We have developed a light source that addresses the challenges in uniform, multiwavelength light distribution for large area artificial dPDT across curved anatomical surfaces. Copyright © 2018. Published by Elsevier B.V.
Energy and daylighting: A correlation between quality of light and energy consciousness
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krug, N.
1997-12-31
Energy and Daylighting, an advanced topics graduate/professional elective has been established to help the student develop a deeper understanding of Architectural Daylighting, Energy Conserving Design, and Material/Construction/Methods through direct application. After a brief survey of the principles and applications of current and developing attitudes and techniques in energy conservation and natural lighting strategies is conducted (in order to build upon previous courses), an extensive exercise follows which allows the student the opportunity for direct applications. Both computer modeling/analysis and physical modeling (light box simulation with photographic documentation) are employed to focus attention on the interrelationships between natural lighting and passivemore » energy conserving design--all within the context of establishing environmental (interior) quality and (exterior) design direction. As a result, students broaden their understanding of natural light and energy conservation as design tools; the importance of environmental responsibility, both built and natural environments; and using computer analysis as a design tool. This presentation centers around the activities and results obtained from explorations into Energy and Daylighting. Discussion will highlight the course objectives, the methodology involved in the studies, specific requirements and means of evaluation, a slide show of befores and afters (results), and a retrospective look at the course`s value, as well as future directions and implications.« less
Fathy, Ghada; Asaad, Marwa Kamal; Rasheed, Haval Mohamad
2017-07-01
Conventional photodynamic therapy is associated with inconveniently long clinic visits and discomfort during therapy. Daylight-photodynamic therapy (DL-PDT) is an effective treatment, nearly pain free and more convenient for both the clinics and patients. There are no published studies of methylene blue (MB) as a photosensitizer (PS) used in DL-PDT. Forty patients had multiple plane warts; 20 patients were subjected to DL-PDT with topical 10% methylene blue gel, and 20 patients were subjected to DL-PDT with hematoxylin (placebo). Improvement was evaluated by change of the number of warts and the dermoscope picture. A total of 20 (100%) patients in group II showed no response to placebo, 13 patients (65%) in group I showed complete clearance, 2 (10%) patients showed a good response, and 5 (25%) patients had poor response to treatment (P < 0.01). No serious side effects and patients tolerated the pain well. No relapse was detected during the follow-up period (12 months). Daylight exposure was not monitored with a dosimeter. Daylight-PDT using MB is safe, easy to carry out, economic, effective, acceptable cosmetic results with no recurrence, convenient especially for children and nearly painless treatment. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Energy performance of semi-transparent PV modules for applications in buildings
NASA Astrophysics Data System (ADS)
Fung, Yu Yan
Owing to the increasing awareness on energy conservation and environmental protection, building-integrated photovoltaic (BIPV) has been developed rapidly in the past decade. A number of research studies have been conducted on the energy performance of BIPV systems. However, most of the previous studies focused on the systems that incorporated with opaque type PV modules, little attention has been devoted to semi-transparent type PV modules, which have been commonly integrated in modern architectures. This thesis aims at evaluating the energy performance of the semi-transparent BIPV modules, including heat gains to the indoor environment, power generation from the PV modules and daylight utilization. Solar radiation intensity on PV module's surfaces is an essential parameter for assessing energy performance of the PV modules. Different slope solar radiation models are analyzed and compared. The model that best suits Hong Kong situations is selected for the further development of the energy performance of the BIPV modules. The optimum orientation and tilted angle are determined in the analysis. In addition to the solar radiation models, a detailed investigation on the heat gain through the semi-transparent BIPV modules is carried out in this study. A one-dimensional transient heat transfer model, the SPVHG model, for evaluating the thermal performance of the semi-transparent BIPV modules is developed. The SPVHG model considers in detail the energy that is transmitted, absorbed and reflected in each element of the BIPV modules such as solar cells and glass layers. A computer program of the model is written accordingly. By applying the SPVHG model, the heat gain through the semi-transparent BIPV module of any thickness can be determined for any solar irradiance level. The annual performance can also be assessed by inputting annual weather data to the model. In order to verify the SPVHG model, laboratory tests have been carried out on semi-transparent BIPV modules. A well-insulated calorimeter box and an adjustable steady-state type solar simulator which can provide up to 1600 W/m2 have been used in the tests. Energy that transmitted through the semi-transparent BIPV modules and entered the calorimeter box was evaluated. It was found that the experimental results and the simulated results support each other. The SPVHG model is validated and can be used for further studies. Other than heat transfer, power production and the daylight utilization are also the vital parts in the energy performance assessment of the semi-transparent BIPV module for applications in building facades. Power generation models of both opaque and semi-transparent BIPV modules are investigated in this study. In order to test the validity of the power generation model, measurements on a BIPV system of an existing building are carried out. The measurement results reveal a good validity of the power generation model. Only a minor modification to the model is required. The daylight utilization is evaluated by using an indoor illuminance model. The model estimates the mean internal illuminance on the working plane of a room when there is both sunlight and skylight. Consequently, the power saving due to the daylight utilization can be determined. By using the SPVHG model together with the power generation model and the indoor illuminance model, the energy performance, in terms of electricity benefit, of building facades that incorporated with semi-transparent BIPV modules is evaluated. Different scenarios are studied by changing various parameters such as the window to wall ratios, thickness and efficiency of the solar cells. The results show that the solar cells within the semi-transparent BIPV modules significantly reduce the solar heat gain and thus reduce the power consumption of air-conditioning systems. Taking into account the impacts of PV electricity generation and daylight utilization, the optimum solar cell area ratio in the PV modules varies from 0.7 to 0.9 for different window-to-wall ratios of the building facade. The largest net electricity benefit of the BIPV facade under the simulation conditions is around 120 kWh/m 2. The SPVHG model developed in this study is a precise model for calculating the amount of heat gains through the semi-transparent BIPV modules. By considering also the power generation and daylight utilization, the electricity benefit of different BIPV facade configurations can be simulated. This information should help engineers predict the cooling load due to the BIPV facade and thus review their designs for energy efficiency optimization. On the whole, the results of this study provide valuable reference to local engineers, designers and professionals for efficient BIPV facade applications.
Fabrication and characterization of Aerogel-Polydimethyl siloxane (PDMS) Insulation Film
NASA Astrophysics Data System (ADS)
Noh, Yeoung ah; Song, Sinae; Taik Kim, Hee
2018-03-01
The building has a large impact on the space heating demand and the indoor environment is affected by climate or daylight. Hence, silica aerogel has generally used as a film to reduce the coefficient of the window in the building. Silica aerogel is a suitable material to apply for insulation material with lower thermal conductivity than that of air to save interior energy. However expensive precursor and drying process were the main issue of the silica aerogel synthesis and practical usage. We attempt to fabricate aerogel insulation film for energy saving through the economic process under ambient pressure. Silica aerogel was synthesized from rice husk ash, which was an agricultural waste to be able to recycle. Taguchi design was used to optimize the parameters (amount of rice husk ash, pH, aging time) controlling the surface area of silica aerogel. The silica aerogel is prepared by sol-gel processing through acidic treatment and aging. The silica aerogel was obtained by modification of silica hydrogel surface and dry at ambient pressure. Finally, aerogel film was respectively fabricated by the different content of aerogel in polydimethylsiloxane (PDMS). Silica aerogel obtained 21 – 24nm average particle size was analyzed by SEM and silica aerogel with high surface area (832.26 m2/g), pore size ( 3.30nm ) was characterized by BET. Then silica Aerogel – PDMS insulation film with thermal conductivity (0.002 W/mK) was analyzed by thermal wave system. The study demonstrates an eco-friendly and low-cost route toward silica – PDMS insulation film with low thermal conductivity (0.002 W/mK).
NASA Technical Reports Server (NTRS)
Salomnson, Vincent V.
2003-01-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) on the Earth Observing System (EOS) Terra Mission began to produce data in February 2000. The EOS Aqua mission was launched successfully May 4,2002 with another MODIS on it and "first light" observations occurred on June 24,2002. The Terra MODIS is in a sun-synchronous orbit going north to south in the daylight portion of the orbit crossing the equator at about 1030 hours local time. The Aqua spacecraft operates in a sun-synchronous orbit going south to north in the daylight portion of the orbit crossing the equator at approximately 1330 hours local time. The spacecraft, instrument, and data systems for both MODIS instruments are performing well and are producing a wide variety of data products useful for scientific and applications studies in relatively consistent fashion extending from November 2000 to the present. Within the approximately 40 MODIS data products, several are new and represent powerful and exciting capabilities such the ability to provide observations over the globe of fire occurrences, microphysical properties of clouds and sun-stimulated fluorescence from phytoplankton in the surface waters of the ocean. The remainder of the MODIS products exceeds or, at a minimum, matches the capabilities of products from heritage sensors such as, for example, the Advanced Very High Resolution Radiometer (AVHRR). Efforts are underway to provide data sets for the greater Earth science community and to improve access to these products at the various Distributed Active Archive Centers (DAAC's) or through Direct Broadcast (DB) stations.
NASA Technical Reports Server (NTRS)
Monk, T. H.; Buysse, D. J.; Billy, B. D.; Kennedy, K. S.; Kupfer, D. J.
1997-01-01
As part of a larger bedrest study involving various life science experiments, a study was conducted on the effects of 17 days of continuous bedrest and elimination of daylight on circadian rectal temperature rhythms, mood, alertness, and sleep (objective and diary) in eight healthy middle-aged men. Sleep was timed from 2300 to 0700 hours throughout. Three 72-hour measurement blocks were compared: ambulatory prebedrest, early bedrest (days 5-7), and late bedrest (days 15-17). Temperature rhythms showed reduced amplitude and later phases resulting from the bedrest conditions. This was associated with longer nocturnal sleep onset latencies and poorer subjectively rated sleep but with no reliable changes in any of the other sleep parameters. Daily changes in posture and/or exposure to daylight appear to be important determinants of a properly entrained circadian system.
Stapanian, Martin A.; Kocovsky, Patrick M.; Adams, Jean V.
2009-01-01
1. Non-native mussels have increased water clarity in many lakes and streams in North America and Europe. Diel variation in catchability of some fish species has been linked to visibility during survey trawls (used to measure escapement). 2. Water clarity increased in nearshore areas of western Lake Erie by the early 1990s, following passage of legislation in 1972 to improve water quality (e.g. reduce phosphorus loading) and the invasion of dreissenid mussels (Dreissena spp.) beginning in 1987. 3. We hypothesised that increased water clarity in Lake Erie resulted in decreased catchability of young-of-year (age-0) yellow perch (Perca flavescens Mitchill) during daylight compared to during night. We used a two-tiered modelling approach to test this hypothesis on the ratio (R) of catch per hour (CPH) during night to CPH during daylight in bottom trawl surveys conducted during 1961-2005. 4. First, we examined seven a priori models. The first model, the 'null' model, represented no change in R over time. Three more models tested whether the timing of the change in R was associated with passage of water quality legislation only, dreissenids only (two-period models) and both legislation and dreissenids (three-period models). Three additional models included a 3-year lag before the effects of legislation, dreissenids or both occurred. Secondly, all possible two- and three-period models with a minimum of 2 years per time period were explored a posteriori. The a posteriori procedure determined the temporal transitions to higher R that were best supported by the data, without regard to a priori hypotheses. 5. Night CPH was greater than daylight CPH in 3 of 11 years during 1961-72, in 10 of 15 years during 1973-87, and in 14 of 18 years during 1988-2005. During 1991-2005 night CPH exceeded daylight CPH in all years except one, and night CPH was more than twice daylight CPH in 10 years during this period. 6. The best a priori model had two periods, with a break between 1990 and 1991, corresponding to 3 years after the dreissenid invasion. Similarly, the best two- and three-period a posteriori models both had breaks between 1990 and 1991. The results supported our hypothesis that age-0 yellow perch exhibited a transition to lower catchability during daylight compared to night, and the timing of the transition coincided with the establishment of dreissenid mussels. 7. The most plausible mechanism for our results was increased visibility of the trawl during daylight, resulting in increased avoidance of the trawl. These results have potential applications wherever non-native mussels have increased water clarity.
Use of Daylight and Aesthetic Image of Glass Facades in Contemporary Buildings
NASA Astrophysics Data System (ADS)
Roginska-Niesluchowska, Malgorzata
2017-10-01
The paper deals with the architecture of contemporary buildings in respect to their aesthetic image created by the use of natural light. Sustainability is regarded as a governing principle of contemporary architecture, where daylighting is an important factor as it affects energy consumption and environmental quality of the space inside a building. Environmental awareness of architecture, however, involves a much wider and more holistic view of design. The quality of sustainable architecture can be considered in its aesthetic and cultural context with regard to landscape, local tradition, and connection to the surrounding world. This approach is associated with the social mission of architecture, i.e. providing appropriate space for living, facilitating social relations and having positive impact on people. The purpose of the research is to study the use of daylight in creating an aesthetic image of contemporary buildings. The author focuses mainly on public buildings largely dedicated to art and culture which satisfy high functional and aesthetic requirements. The paper examines the genesis and current trends in the aesthetic image of modern buildings which use daylight as the main design strategy, focusing on the issues of glass facades. The main attention is given to the shaping of representative public areas which feature the glass facades. The research has been based on a case study, critical review of literature review, observation and synthesis. The study identifies and classifies different approaches to using daylight in these areas and highlights changes in the aesthetics of architecture made of glass, which uses daylight as the main design strategy. These changes are primarily caused by the development and spreading of new glazing materials and the use of digital method of design. The influence of light and its mode depends on glass materials but also on the local conditions of the site, and has a significant impact on the relationship between architecture and its natural and cultural environment. The subordination of architectural concept to the idea of natural lighting builds the relationship between form, function and the context of architecture, and is expressed in its structural, material and spatial properties, and in the resulting aesthetic order. Search for new architectural solutions is defined by local topographical, climatic, biological and cultural conditions. The architecture subordinate to the conception of contribution of light corresponds to the aesthetic aspirations of sustainability.
Sanders, William J.; Snyder, Marvin K.; Harter, James W.
1983-01-01
The amount of building heating, cooling and daylighting is controlled by at least one pair of solar energy passing panels, with each panel of the pair of panels being exposed to a separate direction of sun incidence. A shutter-shade combination is associated with each pair of panels and the shutter is connected to the shade so that rectilinear movement of the shutter causes pivotal movement of the shade.
Moving into the Light: The AEOS Telescope in the Daytime Operating Environment
NASA Astrophysics Data System (ADS)
Mayo, J.
Abstract for Coming into the Light: The AEOS Telescope in the Daytime Operating Environment” Interest in daylight operation for the AEOS 3.67-m Telescope first surfaced during the preparation of the AEOS specification documentation in 1991. The author and Lt Rich Elder prepared, edited and combined requirements inputs from AFRL technical staff to create the final RFP document. In this released specification, AEOS daylight performance was limited to best effort, although provisions for adding secondary mirror sky light baffling were to be provided. In 1993, during the AEOS construction phase, AFRL requested that the author prepare a report on special considerations for operating AEOS in the solar illuminated daytime environment. This report was published and briefed to AFRL and Space Command at that time. Interest in this topic at AMOS was rekindled in 2007 by Dr Joe Janni and Lt Col Scott Hunt. The author updated his 1993 report and in June 2007 presented AEOS 1993 Daylight Operation Study Revisited” at AMOS. Subsequently, Dr Stacie Williams spearheaded additional work in this critical technical area. Recent efforts at Tau Technologies LLC have focused on external AEOS telescope baffling and shielding options assessment, solar irradiation effects on optical components, especially the primary mirror, and on modeling the solar illumination on the entire telescope during daylight operation. Solid Works and Illustrator simulation models have been developed and exercised.
Chemical reactions in perfume ageing.
Blakeway, J M; Frey, M L; Lacroix, S; Salerno, M S
1987-10-01
Summary The interactions between a typical range of perfume materials, alcohol, water, air, elevated temperatures and daylight have been studied. The changes of composition, acidity, peroxide content and the formation of new molecules were followed. The stabilizing effects of UV absorbers, antioxidants and sequestering agents were examined; - the formation of acid reaction products was accelerated by air, temperature, daylight and the presence of natural products; - peroxide formation was accelerated by heat and light and the presence of air; as the acidity increased, the peroxides decomposed; - the acetalization of other aldehydes was accelerated by temperature and daylight and the presence of natural products up to 40% of certain aldehydes may be converted into acetals after 3 months at 37 degrees C; - many stereoisomerizations occur, e.g., transisoeugenol is converted up to 10% into the cis isomer after 3 months at 37 degrees C and 58% in daylight; - evaluation of antioxidants UV absorbers and sequestering agents showed a significant protection against deterioration only by EDTA dipotassium salt; - ethanol was converted into acetaldehyde and its diethylacetal by peroxides present and formed on ageing up to 0.08%. Natural products accelerated this formation; - the reaction between benzoyl peroxide and ethanol was shown to yield up to 63% of acetaldehyde+diethyl acetal whilst di-t-butyl peroxide gave only 23% under the same conditions. These results go some way to explaining odour changes in perfume ageing.
Final Technical Report: Commercial Advanced Lighting Control (ALC) Demonstration and Deployment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arnold, Gabe
This three-year demonstration and deployment project sought to address market barriers to accelerating the adoption of Advanced Lighting Controls (ALCs), an underutilized technology with low market penetration. ALCs are defined as networked, addressable lighting control systems that utilize software or intelligent controllers to combine multiple energy-saving lighting control strategies in a single space (e.g., smart-time scheduling, daylight harvesting, task tuning, occupancy control, personal control, variable load-shedding, and plug-load control). The networked intelligent aspect of these systems allows applicable lighting control strategies to be combined in a single space, layered over one another, maximizing overall energy-savings. The project included five realmore » building demonstrations of ALCs across the Northeast US region. The demonstrations provided valuable data and experience to support deployment tasks that are necessary to overcome market barriers. These deployment tasks included development of training resources for building designers, installers, and trades, as well as development of new energy efficiency rebates for the technology from Efficiency Forward’s utility partners. Educating designers, installers, and trades on ALCs is a critical task for reducing the cost of the technology that is currently inflated due to perceived complexity and unfamiliarity with how to design and install the systems. Further, utility and non-utility energy efficiency programs continue to relegate the technology to custom or ill-suited prescriptive program designs that do not effectively deploy the technology at scale. This project developed new, scalable rebate approaches for the technology. Efficiency Forward utilized their DesignLights Consortium® (DLC) brand and network of 81 DLC member utilities to develop and deploy the results of the project. The outputs of the project have included five published case studies, a six-hour ALC technology training curriculum that has already been deployed in five US states, and new rebates offered for the technology that have been deployed by a dozen utilities across the US. Widespread adoption of ALC technology in commercial buildings would provide tremendous benefits. The current market penetration of ALC systems is estimated at <0.1% in commercial buildings. If ALC systems were installed in all commercial buildings, approximately 1,051 TBtu of energy could be saved. This would translate into customer cost savings of approximately $10.7 billion annually.« less
Strategies to improve energy efficiency in sewage treatment plants
NASA Astrophysics Data System (ADS)
Au, Mau Teng; Pasupuleti, Jagadeesh; Chua, Kok Hua
2013-06-01
This paper discusses on strategies to improve energy efficiency in Sewage Treatment Plant (STP). Four types of STP; conventional activated sludge, extended aeration, oxidation ditch, and sequence batch reactor are presented and strategized to reduce energy consumption based on their influent flow. Strategies to reduce energy consumption include the use of energy saving devices, energy efficient motors, automation/control and modification of processes. It is envisaged that 20-30% of energy could be saved from these initiatives.
Portable+: A Ubiquitous And Smart Way Towards Comfortable Energy Savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, Milan; Singh, Amarjeet; Chandan, Vikas
An air conditioner (AC) consumes a significant proportion of the total household power consumption. Primarily used in developing countries, decentralised AC has an inbuilt thermostat to cool the room to a temperature, manually set by the users. However, residents are incapable of specifying their goal through these thermostats - maximise their comfort or save AC energy. State-of-the-art portable thermostats emulate AC remotes and assist occupants in remotely changing the thermostat temperature, through their smartphones. We propose extending such thermostats to portable+ by adding a Comfort-Energy Trade-off (CET) knob, realised through an optimisation framework to allow users to balance their comfortmore » and the savings without worrying about the right set temperature. Analysis based on real data, collected from a controlled experiment (across two rooms for two weeks) and an in-situ deployment (across five rooms for three months), indicates that portable+ thermostats can reduce residents’ discomfort by 23% (CET selection for maximal comfort) and save 26% energy when CET is set for maximising savings.« less
Trivedi, Amit K; Rani, Sangeeta; Kumar, Vinod
2006-01-01
Background A stable and systematic daily change in light levels at dawn and dusk provides the most reliable indicator of the phase of the day. It is likely that organisms have evolved mechanisms to use these twilight transitions as the primary zeitgeber to adjust their circadian phases. In this study, we investigated under natural illumination conditions the effects of daylight exposure restricted to twilights on the timing of testicular regression and locomotor activity of the house sparrow (Passer domesticus), which possesses a strongly self-sustaining circadian system. Methods and results Two experiments were performed on adult male house sparrows. Beginning in the third week of April, the first experiment examined whether exposure to natural daylight only during twilights influenced the timing of testicular regression and concomitant changes in testosterone-dependent beak color of reproductively mature sparrows. Interestingly, there was a significant delay in testicular regression and depigmentation of the beak in sparrows exposed to natural daylight (NDL) only during twilights as compared to those exposed to NDL all day. The second experiment examined twice in the year, around the equinoxes (March and September), the effects of exposure to twilights only on the daily activity rhythm of sparrows kept in an outdoor aviary. Five of 7 birds continued exhibiting entrained activity rhythms when exposed only to twilights (NDL minus day light from sunrise to sunset) in September, but not in March. Both in NDL and twilight conditions, March birds had significantly lower activity counts than September birds. Conclusion Exposure to natural daylight only during twilights delayed the timing of testicular regression and concomitant depigmentation of the beak but did not affect the daily activity rhythm in male sparrows. This suggests that daily twilights can serve as cues for regulation of the circadian activity rhythm but not for the photoperiodic regulation of testicular cycle in the house sparrow. PMID:16553964
How daylight influences high-order chromatic descriptors in natural images.
Ojeda, Juan; Nieves, Juan Luis; Romero, Javier
2017-07-01
Despite the global and local daylight changes naturally occurring in natural scenes, the human visual system usually adapts quite well to those changes, developing a stable color perception. Nevertheless, the influence of daylight in modeling natural image statistics is not fully understood and has received little attention. The aim of this work was to analyze the influence of daylight changes in different high-order chromatic descriptors (i.e., color volume, color gamut, and number of discernible colors) derived from 350 color images, which were rendered under 108 natural illuminants with Correlated Color Temperatures (CCT) from 2735 to 25,889 K. Results suggest that chromatic and luminance information is almost constant and does not depend on the CCT of the illuminant for values above 14,000 K. Nevertheless, differences between the red-green and blue-yellow image components were found below that CCT, with most of the statistical descriptors analyzed showing local extremes in the range 2950 K-6300 K. Uniform regions and areas of the images attracting observers' attention were also considered in this analysis and were characterized by their patchiness index and their saliency maps. Meanwhile, the results of the patchiness index do not show a clear dependence on CCT, and it is remarkable that a significant reduction in the number of discernible colors (58% on average) was found when the images were masked with their corresponding saliency maps. Our results suggest that chromatic diversity, as defined in terms of the discernible colors, can be strongly reduced when an observer scans a natural scene. These findings support the idea that a reduction in the number of discernible colors will guide visual saliency and attention. Whatever the modeling is mediating the neural representation of natural images, natural image statistics, it is clear that natural image statistics should take into account those local maxima and minima depending on the daylight illumination and the reduction of the number of discernible colors when salient regions are considered.
Effects of weather conditions, light conditions, and road lighting on vehicle speed.
Jägerbrand, Annika K; Sjöbergh, Jonas
2016-01-01
Light conditions are known to affect the number of vehicle accidents and fatalities but the relationship between light conditions and vehicle speed is not fully understood. This study examined whether vehicle speed on roads is higher in daylight and under road lighting than in darkness, and determined the combined effects of light conditions, posted speed limit and weather conditions on driving speed. The vehicle speed of passenger cars in different light conditions (daylight, twilight, darkness, artificial light) and different weather conditions (clear weather, rain, snow) was determined using traffic and weather data collected on an hourly basis for approximately 2 years (1 September 2012-31 May 2014) at 25 locations in Sweden (17 with road lighting and eight without). In total, the data included almost 60 million vehicle passes. The data were cleaned by removing June, July, and August, which have different traffic patterns than the rest of the year. Only data from the periods 10:00 A.M.-04:00 P.M. and 06:00 P.M.-10:00 P.M. were used, to remove traffic during rush hour and at night. Multivariate adaptive regression splines was used to evaluate the overall influence of independent variables on vehicle speed and nonparametric statistical testing was applied to test for speed differences between dark-daylight, dark-twilight, and twilight-daylight, on roads with and without road lighting. The results show that vehicle speed in general depends on several independent variables. Analyses of vehicle speed and speed differences between daylight, twilight and darkness, with and without road lighting, did not reveal any differences attributable to light conditions. However, vehicle speed decreased due to rain or snow and the decrease was higher on roads without road lighting than on roads with lighting. These results suggest that the strong association between traffic accidents and darkness or low light conditions could be explained by drivers failing to adjust their speed to the reduced visibility in dark conditions.
Effect of extraoral aging conditions on mechanical properties of maxillofacial silicone elastomer.
Hatamleh, Muhanad M; Polyzois, Gregory L; Silikas, Nick; Watts, David C
2011-08-01
The purpose of this study was to investigate the effect of extraoral human and environmental conditions on the mechanical properties (tensile strength and modulus, elongation, tear strength hardness) of maxillofacial silicone elastomer. Specimens were fabricated using TechSil-S25 silicone elastomer (Technovent Ltd, Leeds, UK). Eight groups were prepared (21 specimens in each group; eight tensile, eight tear, five hardness) and conditioned differently as follows (groups 1 through 8): Dry storage for 24 hours; dry storage in dark for 6 months; storage in simulated sebum solution for 6 months; storage in simulated acidic perspiration for 6 months; accelerated artificial daylight aging under controlled moisture for 360 hours; outdoor weathering for 6 months; storage in antimicrobial silicone-cleaning solution for 30 hours; and mixed conditioning of sebum storage and light aging for 360 hours. The conditioning period selected simulated a prosthesis being in service for up to 12 months. Tensile and tear test specimens were fabricated and tested according to the International Standards Organization (ISO) standards no. 37 and 34, respectively. Shore A hardness test specimens were fabricated and tested according to the American Standards for Testing and Materials (ASTM) D 2240. Data were analyzed with one-way ANOVA, Bonferroni, and Dunnett's T3 post hoc tests (p < 0.05). Weibull analysis was also used for tensile strength and tear strength. Statistically significant differences were evident among all properties tested. Mixed conditioning of simulated sebum storage under accelerated artificial daylight aging significantly degraded mechanical properties of the silicone (p < 0.05). Mechanical properties of maxillofacial elastomers are adversely affected by human and environmental factors. Mixed aging of storage in simulated sebum under accelerated daylight aging was the most degrading regime. Accelerated aging of silicone specimens in simulated sebum under artificial daylight for 12 months of simulated clinical service greatly affected functional properties of silicone elastomer; however, in real practice, the effect is modest, since sebum concentration is lower, and daylight is less concentrated. © 2011 by The American College of Prosthodontists.
Flight directions of passerine migrants in daylight and darkness: A radar and direct visual study
NASA Technical Reports Server (NTRS)
Gauthreaux, S. A., Jr.
1972-01-01
The application of radar and visual techniques to determine the migratory habits of passerine birds during daylight and darkness is discussed. The effects of wind on the direction of migration are examined. Scatter diagrams of daytime and nocturnal migration track directions correlated with wind direction are presented. It is concluded that migratory birds will fly at altitudes where wind direction and migratory direction are nearly the same. The effects of cloud cover and solar obscuration are considered negligible.
The Taranaki daylight fireball, 1999 July 7
NASA Astrophysics Data System (ADS)
McCormick, Jennie
2006-10-01
The New Zealand Taranaki Daylight Fireball was observed on 1999 July 7 from various areas across the North and South Islands of New Zealand and had an apparent magnitude brighter than -20. The event produced more than one hundred handwritten reports, drawings, and paintings from eyewitnesses; video and audio recordings, seismic trace data, and confirmation of detection by the United States Defense Department satellites. A detailed case study based on this data shows that observations by the public are invaluable when compiling a formal history of such events.
2006-01-01
Systems, Thermal Comfort 1 Credit 3 Enhanced Commissioning 1 Credit 7.1 Thermal Comfort , Compliance 1 Credit 4 Enhanced Refrigerant Management 1 Credit 7.2... Thermal Comfort , Validation ? Credit 5 Measurement & Verification 1 Credit 8.1 Daylight & Views, Daylight 75% of Spaces 1 Credit 6 Green Power N...Systems, Thermal Comfort 1 Credit 3 Enhanced Commissioning 1 Credit 7.1 Thermal Comfort , Compliance 1 Credit 4 Enhanced Refrigerant Management 1 Credit 7.2
Daylight time-resolved photographs of lightning.
Qrville, R E; Lala, G G; Idone, V P
1978-07-07
Lightning dart leaders and return strokes have been recorded in daylight with both good spatial resolution and good time resolution as part of the Thunder-storm Research International Program. The resulting time-resolved photographs are apparently equivalent to the best data obtained earlier only at night. Average two-dimensional return stroke velocities in four subsequent strokes between the ground and a height of 1400 meters were approximately 1.3 x 10(8) meters per second. The estimated systematic error is 10 to 15 percent.
Option pricing: a flexible tool to disseminate shared savings contracts.
Friedberg, Mark W; Buendia, Anthony M; Lauderdale, Katherine E; Hussey, Peter S
2013-08-01
Due to volatility in healthcare costs, shared savings contracts can create systematic financial losses for payers, especially when contracting with smaller providers. To improve the business case for shared savings, we calculated the prices of financial options that payers can "sell" to providers to offset these losses. Using 2009 to 2010 member-level total cost of care data from a large commercial health plan, we calculated option prices by applying a bootstrap simulation procedure. We repeated these simulations for providers of sizes ranging from 500 to 60,000 patients and for shared savings contracts with and without key design features (minimum savings thresholds,bonus caps, cost outlier truncation, and downside risk) and under assumptions of zero, 1%, and 2% real cost reductions due to the shared savings contracts. Assuming no real cost reduction and a 50% shared savings rate, per patient option prices ranged from $225 (3.1% of overall costs) for 500-patient providers to $23 (0.3%) for 60,000-patient providers. Introducing minimum savings thresholds, bonus caps, cost outlier truncation, and downside risk reduced these option prices. Option prices were highly sensitive to the magnitude of real cost reductions. If shared savings contracts cause 2% reductions in total costs, option prices fall to zero for all but the smallest providers. Calculating the prices of financial options that protect payers and providers from downside risk can inject flexibility into shared savings contracts, extend such contracts to smaller providers, and clarify the tradeoffs between different contract designs, potentially speeding the dissemination of shared savings.
Finkelstein, Eric A; Allaire, Benjamin T; Dibonaventura, Marco Dacosta; Burgess, Somali M
2012-01-01
The objective of this study was to estimate the time to breakeven and 5-year net costs of laparoscopic adjustable gastric banding (LAGB) taking both direct and indirect costs and cost savings into account. Estimates of direct cost savings from LAGB were available from the literature. Although longitudinal data on indirect cost savings were not available, these estimates were generated by quantifying the relationship between medical expenditures and absenteeism and between medical expenditures and presenteeism (reduced on-the-job productivity) and combining these elasticity estimates with estimates of the direct cost savings to generate total savings. These savings were then combined with the direct and indirect costs of the procedure to quantify net savings. By including indirect costs, the time to breakeven was reduced by half a year, from 16 to 14 quarters. After 5 years, net savings in medical expenditures from a gastric banding procedure were estimated to be $4970 (±$3090). Including absenteeism increased savings to $6180 (±$3550). Savings were further increased to $10,960 (±$5864) when both absenteeism and presenteeism estimates were included. This study presented a novel approach for including absenteeism and presenteeism estimates in cost-benefit analyses. Application of the approach to gastric banding among surgery-eligible obese employees revealed that the inclusion of indirect costs and cost savings improves the business case for the procedure. This approach can easily be extended to other populations and treatments. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Accelerating locomotor savings in learning: compressing four training days to one.
Day, Kevin A; Leech, Kristan A; Roemmich, Ryan T; Bastian, Amy J
2018-06-01
Acquiring new movements requires the capacity of the nervous system to remember previously experienced motor patterns. The phenomenon of faster relearning after initial learning is termed "savings." Here we studied how savings of a novel walking pattern develops over several days of practice and how this process can be accelerated. We introduced participants to a split-belt treadmill adaptation paradigm for 30 min for 5 consecutive days. By training day 5, participants were able to produce near-perfect performance when switching between split and tied-belt environments. We found that this was due to their ability to shift specific elements of their stepping pattern to account for the split treadmill speeds from day to day. We also applied a state-space model to further characterize multiday locomotor savings. We then explored methods of achieving comparable savings with less total training time. We studied people training only on day 1, with either one extended split-belt exposure or alternating four times between split-belt and tied-belt conditions rapidly in succession. Both of these single-day training groups were tested again on day 5. Experiencing four abbreviated exposures on day 1 improved the performance on day 5 compared with one extended exposure on day 1. Moreover, this abbreviated group performed similarly to the group that trained for 4 consecutive days before testing on day 5, despite only having one-quarter of the total training time. These results demonstrate that we can leverage training structure to achieve a high degree of performance while minimizing training sessions. NEW & NOTEWORTHY Learning a new movement requires repetition. Here, we demonstrate how to more efficiently train an adapted walking pattern. By compressing split-belt treadmill training delivered over 4 days to four abbreviated bouts of training delivered on the first day of training, we were able to induce equivalent savings over a 5-day span. These results suggest that we can manipulate the delivery of training to most efficiently drive multiday learning of a novel walking pattern.
Daylight photodynamic therapy with methyl-aminolevulinate for the treatment of actinic cheilitis.
Fai, Dario; Romanello, Eugenio; Brumana, Marta Benedetta; Fai, Carlotta; Vena, Gino Antonio; Cassano, Nicoletta; Piaserico, Stefano
2015-01-01
Actinic cheilitis (AC) is a common premalignant condition that requires an effective treatment to reduce the risk of malignant transformation. Photodynamic therapy (PDT) has been recently added to the armamentarium available for AC treatment. Daylight PDT (D-PDT) is a novel PDT modality in which the activation of the topical photosensitizer is induced by the exposure to natural daylight instead of artificial light sources without preliminary occlusion. This simplified procedure was found to be more tolerated as compared to conventional PDT. We report our preliminary experience on the use of D-PDT using methyl-aminolevulinate cream in 10 patients with refractory AC of the lower lip. Patients received two consecutive D-PDT sessions with an interval of 7-14 days. At 3 months after therapy, a complete response was observed in seven patients, with sustained results in five patients over an observational period of 6-12 months. Treatment was well tolerated. © 2015 Wiley Periodicals, Inc.
A new method for assessing the risk of accident associated with darkness.
Johansson, Osten; Wanvik, Per Ole; Elvik, Rune
2009-07-01
This paper presents a new method for assessing the risk of accidents associated with darkness. The method estimates the risk of accident associated with darkness in terms of an odds ratio, which is defined as follows: [(number of accidents in darkness in a given hour of the day)/(number of accidents in daylight in the same hour of the day)]/[(Number of accidents in a given comparison hour when the case hour is dark)/(Number of accidents in a given comparison hour when the case hour is in daylight)]. This estimate of the risk of accident associated with darkness does not require data on exposure, but relies on the count of accidents in the same pair of hours throughout the year. One of the hours is dark part of the year, but has daylight the rest of the year. The comparison hour, which has daylight the whole year, is used to control for seasonal variations. The aim of relying on the same pair of hours throughout the year is to minimise the influence of potentially confounding factors. Estimates of the risk of injury accidents associated with darkness are developed on the basis of accident data for Norway, Sweden and the Netherlands. It is found that the risk of an injury accident increases by nearly 30% in darkness in urban areas, by nearly 50% in rural areas, and by about 40% for urban and rural areas combined (adjusted estimate).
The effect of ambient lighting on Laser Doppler Imaging of a standardized cutaneous injury model.
Pham, Alan Chuong Q; Hei, Erik La; Harvey, John G; Holland, Andrew Ja
2017-01-01
The aim of this study was to investigate the potential confounding effects of four different types of ambient lighting on the results of Laser Doppler Imaging (LDI) of a standardized cutaneous injury model. After applying a mechanical stimulus to the anterior forearm of a healthy volunteer and inducing a wheal and arteriolar flare (the Triple response), we used a Laser Doppler Line Scanner (LDLS) to image the forearm under four different types of ambient lighting: light-emitting-diode (LED), compact fluorescent lighting (CFL), halogen, daylight, and darkness as a control. A spectrometer was used to measure the intensity of light energy at 785 nm, the wavelength used by the scanner for measurement under each type of ambient lighting. Neither the LED nor CFL bulbs emitted detectable light energy at a wavelength of 785 nm. The color-based representation of arbitrary perfusion unit (APU) values of the Triple response measured by the scanner was similar between darkness, LED, and CFL light. Daylight emitted 2 mW at 785 nm, with a slight variation tending more towards lower APU values compared to darkness. Halogen lighting emitted 6 mW of light energy at 785 nm rendering the color-based representation impossible to interpret. Halogen lighting and daylight have the potential to confound results of LDI of cutaneous injuries whereas LED and CFL lighting did not. Any potential sources of daylight should be reduced and halogen lighting completely covered or turned off prior to wound imaging.
Arnold, Sarah E J; Chittka, Lars
2012-07-01
Patchy illumination presents foraging animals with a challenge, as the targets being sought may appear to vary in colour depending on the illumination, compromising target identification. We sought to explore how the bumblebee Bombus terrestris copes with tasks involving flower colour discrimination under patchy illumination. Light patches varied between unobscured daylight and leaf-shade, as a bee might encounter in and around woodland. Using a flight arena and coloured filters, as well as one or two different colours of artificial flower, we quantified how bees chose to forage when presented with foraging tasks under patchy illumination. Bees were better at discriminating a pair of similar colours under simulated unobscured daylight illumination than when foraging under leaf-shade illumination. Accordingly, we found that bees with prior experience of simulated daylight but not leaf-shade illumination initially preferred to forage in simulated daylight when all artificial flowers contained rewards as well as when only one colour was rewarding, whereas bees with prior experience of both illuminants did not exhibit this preference. Bees also switched between illuminants less than expected by chance. This means that bees prefer illumination conditions with which they are familiar, and in which rewarding flower colours are easily distinguishable from unrewarding ones. Under patchy illumination, colour discrimination performance was substantially poorer than in homogenous light. The bees' abilities at coping with patchy light may therefore impact on foraging behaviour in the wild, particularly in woodlands, where illumination can change over short spatial scales.
Katz, Erin M; Scott, Ruth M; Thomson, Christopher B; Mesa, Eileen; Evans, Richard; Conzemius, Michael G
2017-11-01
Objective To determine if environmental variables affect the average daily activity counts (AC) of dogs with osteoarthritis (OA) and/or owners' perception of their dog's clinical signs or quality of life. Methods The AC and Canine Brief Pain Inventory (CBPI) owner questionnaires of 62 dogs with OA were compared with daily environmental variables including the following: average temperature (°C), high temperature (°C), low temperature (°C), relative humidity (%), total precipitation (mm), average barometric pressure (hPa) and total daylight hours. Results Daily AC significantly correlated with average temperature and total daylight hours, but average temperature and total daylight hours accounted for less than 1% of variation in AC. No other significant relationships were found between daily AC and daily high temperature, low temperature, relative humidity, total precipitation or average barometric pressure. No statistical relationship was found between daily AC and the CBPI, nor between environmental variables and the CBPI. Canine Brief Pain Inventory scores for pain severity and pain interference decreased significantly over the test period. Clinical Significance The relationship between daily AC and average temperature and total daylight hours was significant, but unlikely to be clinically significant. Thus, environmental variables do not appear to have a clinically relevant bias on AC or owner CBPI questionnaires. The decrease over time in CBPI pain severity and pain interference values suggests owners completing the CBPI in this study were influenced by a caregiver placebo effect. Schattauer GmbH Stuttgart.
NASA Astrophysics Data System (ADS)
Morita, Shogo; Ito, Shusei; Yamamoto, Hirotsugu
2017-02-01
Aerial display can form transparent floating screen in the mid-air and expected to provide aerial floating signage. We have proposed aerial imaging by retro-reflection (AIRR) to form a large aerial LED screen. However, luminance of aerial image is not sufficiently high so as to be used for signage under broad daylight. The purpose of this paper is to propose a novel aerial display scheme that features hybrid display of two different types of images. Under daylight, signs made of cubes are visible. At night, or under dark lighting situation, aerial LED signs become visible. Our proposed hybrid display is composed of an LED sign, a beam splitter, retro-reflectors, and transparent acrylic cubes. Aerial LED sign is formed with AIRR. Furthermore, we place transparent acrylic cubes on the beam splitter. Light from the LED sign enters transparent acrylic cubes, reflects twice in the transparent acrylic cubes, exit and converge to planesymmetrical position with light source regarding the cube array. Thus, transparent acrylic cubes also form the real image of the source LED sign. Now, we form a sign with the transparent acrylic cubes so that this cube-based sign is apparent under daylight. We have developed a proto-type display by use of 1-cm transparent cubes and retro-reflective sheeting and successfully confirmed aerial image forming with AIRR and transparent cubes as well as cube-based sign under daylight.
Measured daylighting potential of a static optical louver system under real sun and sky conditions
Konis, Kyle; Lee, Eleanor S.
2015-05-04
Side-by-side comparisons were made over solstice-to-solstice changes in sun and sky conditions between an optical louver system (OLS) and a conventional Venetian blind set at a horizontal slat angle and located inboard of a south-facing, small-area, clerestory window in a full-scale office testbed. Daylight autonomy (DA), window luminance, and ceiling luminance uniformity were used to assess performance. The performance of both systems was found to have significant seasonal variation, where performance under clear sky conditions improved as maximum solar altitude angles transitioned from solstice to equinox. Although the OLS produced fewer hours per day of DA on average than themore » Venetian blind, the OLS never exceeded the designated 2000 cd/m2 threshold for window glare. In contrast, the Venetian blind was found to exceed the visual discomfort threshold over a large fraction of the day during equinox conditions. Notably, these peak periods of visual discomfort occurred during the best periods of daylighting performance. Luminance uniformity was analyzed using calibrated high dynamic range luminance images. Under clear sky conditions, the OLS was found to increase the luminance of the ceiling as well as produce a more uniform distribution. Furthermore, compared to conventional venetian blinds, the static optical sunlight redirecting system studied has the potential to significantly reduce the annual electrical lighting energy demand of a daylit space and improve the quality from the perspective of building occupants by consistently transmitting useful daylight while eliminating window glare.« less
Way Beyond Widgets: Delivering Integrated Lighting Design in Actionable Solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myer, Michael; Richman, Eric E.; Jones, Carol C.
2008-08-17
Previously, energy-efficiency strategies for commercial spaces have focused on using efficient equipment without providing specific detailed instructions. Designs by experts in their fields are an energy-efficiency product in its own right. A new national program has developed interactive application-specific lighting designs for widespread use in four major commercial sectors. This paper will describe the technical basis for the solutions, energy efficiency and cost-savings methodology, and installations and measurement/verification to-date. Lighting designs have been developed for five types of retail stores (big box, small box, grocery, specialty market, and pharmacy) and are planned for the office, healthcare, and education sectors asmore » well. Nationally known sustainable lighting designers developed the designs using high-performance commercially available products, daylighting, and lighting controls. Input and peer review was received by stakeholders, including manufacturers, architects, utilities, energy-efficiency program sponsors (EEPS), and end-users (i.e., retailers). An interactive web tool delivers the lighting solutions and analyzes anticipated energy savings using project-specific inputs. The lighting solutions were analyzed against a reference building using the space-by-space method as allowed in the Energy Standard for Buildings Except Low-Rise Residential Buildings (ASHRAE 2004) co-sponsored by the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the Illuminating Engineering Society of North America (IESNA). The results showed that the design vignettes ranged from a 9% to 28% reduction in the allowed lighting power density. Detailed control strategies are offered to further reduce the actual kilowatt-hour power consumption. When used together, the lighting design vignettes and control strategies show a modeled decrease in energy consumption (kWh) by 33% to 50% below the baseline design.« less
Improving Quality and Reducing Cost: Designs for Effective Learning.
ERIC Educational Resources Information Center
Twigg, Carol A.
2003-01-01
Discusses 30 institutions participating in a program exploring how large-enrollment introductory courses can be redesigned using technology to extend access to a new population of students without trading quality for cost savings. (EV)
NASA Technical Reports Server (NTRS)
Salomonson, V. V.
2003-01-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) on the Earth Observing System (EOS) Terra Mission began to produce data in February 2000. The Terra MODIS is in a sun-synchronous orbit going north to south in the daylight portion of the orbit crossing the equator at about 1030 hours local time. The spacecraft, instrument, and data systems are performing well and are producing a wide variety of data products useful for scientific and applications studies in relatively consistent fashion extending from November 2000 to the present. Within the approximately 40 MODIS data products, several are new and represent powerful and exciting capabilities such the ability to provide observations over the globe of fire occurrences, microphysical properties of clouds and sun-stimulated fluorescence from phytoplankton in the surface waters of the ocean. The remainder of the MODIS products exceeds or, at a minimum, matches the capabilities of products from heritage sensors such as, for example, the Advanced Very High Resolution Radiometer (AVHRR). Efforts are underway to provide data sets for the greater Earth science community and to improve access to these products at the various Distributed Active Archive Centers (DAACs) or through Direct Broadcast (DB) stations. The EOS Aqua mission was launched successfully May 4,2002 with another MODIS on it. The Aqua spacecraft operates in a sun-synchronous orbit going south to north in the daylight portion of the orbit crossing the equator at approximately 1330 hours local time. Subsequently the Aqua MODIS observations will substantially add to the capabilities of the Terra MODIS for environmental applications and global change studies.
NASA Technical Reports Server (NTRS)
Salomonson, Vincent V.; Houser, Paul (Technical Monitor)
2002-01-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) on the Earth Observing System (EOS) Terra Mission began to produce data in February 2000. The Terra MODIS is in a sun-synchronous orbit going north to south in the daylight portion of the orbit crossing the equator at about 1030 hours local time. The spacecraft, instrument, and data systems are performing well and are producing a wide variety of data products useful for scientific and applications studies in relatively consistent fashion extending from November 2000 to the present. Within the approximately 40 MODIS data products, several are new and represent powerful and exciting capabilities such the ability to provide observations over the globe of fire occurrences, microphysical properties of clouds and sun-stimulated fluorescence from phytoplankton in the surface waters of the ocean. The remainder of the MODIS products exceed or, at a minimum, match the capabilities of products from heritage sensors such as, for example, the Advanced Very High Resolution Radiometer (AVHRR). Efforts are underway to provide data sets for the greater Earth science community and to improve access to these products at the various Distributed Active Archive Centers (DAAC's) or through Direct Broadcast (DB) stations. The MODIS instrument on the EOS Aqua mission should also be expected to be in orbit and functioning in the Spring of 2002. The Aqua spacecraft will operate in a sun-synchronous orbit going south to north in the daylight portion of the orbit crossing the equator at approximately 1330 hours local time. Subsequently the Aqua MODIS observations will substantially add to the capabilities of the Terra MODIS for environmental applications and global change studies.
Daylighting simulation: methods, algorithms, and resources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carroll, William L.
This document presents work conducted as part of Subtask C, ''Daylighting Design Tools'', Subgroup C2, ''New Daylight Algorithms'', of the IEA SHC Task 21 and the ECBCS Program Annex 29 ''Daylight in Buildings''. The search for and collection of daylighting analysis methods and algorithms led to two important observations. First, there is a wide range of needs for different types of methods to produce a complete analysis tool. These include: Geometry; Light modeling; Characterization of the natural illumination resource; Materials and components properties, representations; and Usability issues (interfaces, interoperability, representation of analysis results, etc). Second, very advantageously, there have beenmore » rapid advances in many basic methods in these areas, due to other forces. They are in part driven by: The commercial computer graphics community (commerce, entertainment); The lighting industry; Architectural rendering and visualization for projects; and Academia: Course materials, research. This has led to a very rich set of information resources that have direct applicability to the small daylighting analysis community. Furthermore, much of this information is in fact available online. Because much of the information about methods and algorithms is now online, an innovative reporting strategy was used: the core formats are electronic, and used to produce a printed form only secondarily. The electronic forms include both online WWW pages and a downloadable .PDF file with the same appearance and content. Both electronic forms include live primary and indirect links to actual information sources on the WWW. In most cases, little additional commentary is provided regarding the information links or citations that are provided. This in turn allows the report to be very concise. The links are expected speak for themselves. The report consists of only about 10+ pages, with about 100+ primary links, but with potentially thousands of indirect links. For purposes of the printed version, a list of the links is explicitly provided. This document exists in HTML form at the URL address: http://eande.lbl.gov/Task21/dlalgorithms.html. An equivalent downloadable PDF version, also with live links, at the URL address: http://eande.lbl.gov/Task21/dlalgorithms.pdf. A printed report can be derived directly from either of the electronic versions by simply printing either of them. In addition to the live links in the electronic forms, all report forms, electronic and paper, also have explicitly listed link addresses so that they can be followed up or referenced manually.« less
Inviscid Analysis of Extended Formation Flight
NASA Technical Reports Server (NTRS)
Kless, James; Aftosmis, Michael J.; Ning, Simeon Andrew; Nemec, Marian
2012-01-01
Flying airplanes in extended formations, with separation distances of tens of wingspans, significantly improves safety while maintaining most of the fuel savings achieved in close formations. The present study investigates the impact of roll trim and compressibility at fixed lift coefficient on the benefits of extended formation flight. An Euler solver with adjoint-based mesh refinement combined with a wake propagation model is used to analyze a two-body echelon formation at a separation distance of 30 spans. Two geometries are examined: a simple wing and a wing-body geometry. Energy savings, quantified by both formation drag fraction and span efficiency factor, are investigated at subsonic and transonic speeds for a matrix of vortex locations. The results show that at fixed lift and trimmed for roll, the optimal location of vortex impingement is about 10% inboard of the trailing airplane s wing-tip. Interestingly, early results show the variation in drag fraction reduction is small in the neighborhood of the optimal position. Over 90% of energy benefits can be obtained with a 5% variation in transverse and 10% variation in crossflow directions. Early results suggest control surface deflections required to achieve trim reduce the benefits of formation flight by 3-5% at subsonic speeds. The final paper will include transonic effects and trim on extended formation flight drag benefits.
Tachinardi, Patricia; Valentinuzzi, Verónica S; Oda, Gisele A; Buck, C Loren
The tuco-tuco (Ctenomys aff. knighti) is among the rodent species known to be nocturnal under standard laboratory conditions and diurnal under natural conditions. The circadian thermoenergetics (CTE) hypothesis postulates that switches in activity timing are a response to energetic challenges; daytime activity reduces thermoregulatory costs by consolidating activity to the warmest part of the day. Studying wild animals under both captive and natural conditions can increase understanding of how temporal activity patterns are shaped by the environment and could serve as a test of the CTE hypothesis. We estimated the effects of activity timing on energy expenditure for the tuco-tuco by combining laboratory measurements of metabolic rate with environmental temperature records in both winter and summer. We showed that, in winter, there would be considerable energy savings if activity is allocated at least partially during daylight, lending support to the CTE hypothesis. In summer, the impact of activity timing on energy expenditure is small, suggesting that during this season other factors, such as predation risk, water balance, and social interaction, may have more important roles than energetics in the determination of activity time.
Playback system designed for X-Band SAR
NASA Astrophysics Data System (ADS)
Yuquan, Liu; Changyong, Dou
2014-03-01
SAR(Synthetic Aperture Radar) has extensive application because it is daylight and weather independent. In particular, X-Band SAR strip map, designed by Institute of Remote Sensing and Digital Earth, Chinese Academy of Sciences, provides high ground resolution images, at the same time it has a large spatial coverage and a short acquisition time, so it is promising in multi-applications. When sudden disaster comes, the emergency situation acquires radar signal data and image as soon as possible, in order to take action to reduce loss and save lives in the first time. This paper summarizes a type of X-Band SAR playback processing system designed for disaster response and scientific needs. It describes SAR data workflow includes the payload data transmission and reception process. Playback processing system completes signal analysis on the original data, providing SAR level 0 products and quick image. Gigabit network promises radar signal transmission efficiency from recorder to calculation unit. Multi-thread parallel computing and ping pong operation can ensure computation speed. Through gigabit network, multi-thread parallel computing and ping pong operation, high speed data transmission and processing meet the SAR radar data playback real time requirement.
MODIS Measures Fraction of Sunlight Absorbed by Plants
NASA Technical Reports Server (NTRS)
2002-01-01
At the height of the solar cycle, the Sun is finally displaying some fireworks. This image from the Solar and Heliospheric Observatory (SOHO) shows a large solar flare from June 6, 2000 at 1424 Universal Time (10:24 AM Eastern Daylight Savings Time). Associated with the flare was a coronal mass ejection that sent a wave of fast moving charged particles straight towards Earth. (The image was acquired by the Extreme ultaviolet Imaging Telescope (EIT), one of 12 instruments aboard SOHO) Solar activity affects the Earth in several ways. The particles generated by flares can disrupt satellite communications and interfere with power transmission on the Earth's surface. Earth's climate is tied to the total energy emitted by the sun, cooling when the sun radiates less energy and warming when solar output increases. Solar radiation also produces ozone in the stratosphere, so total ozone levels tend to increase during the solar maximum. For more information about these solar flares and the SOHO mission, see NASA Science News or the SOHO home page. For more about the links between the sun and climate change, see Sunspots and the Solar Max. Image courtesy SOHO Extreme ultaviolet Imaging Telescope, ESA/NASA
NASA Technical Reports Server (NTRS)
2002-01-01
At the height of the solar cycle, the Sun is finally displaying some fireworks. This image from the Solar and Heliospheric Observatory (SOHO) shows a large solar flare from June 6, 2000 at 1424 Universal Time (10:24 AM Eastern Daylight Savings Time). Associated with the flare was a coronal mass ejection that sent a wave of fast moving charged particles straight towards Earth. (The image was acquired by the Extreme ultaviolet Imaging Telescope (EIT), one of 12 instruments aboard SOHO) Solar activity affects the Earth in several ways. The particles generated by flares can disrupt satellite communications and interfere with power transmission on the Earth's surface. Earth's climate is tied to the total energy emitted by the sun, cooling when the sun radiates less energy and warming when solar output increases. Solar radiation also produces ozone in the stratosphere, so total ozone levels tend to increase during the solar maximum. For more information about these solar flares and the SOHO mission, see NASA Science News or the SOHO home page. For more about the links between the sun and climate change, see Sunspots and the Solar Max. Image courtesy SOHO Extreme ultaviolet Imaging Telescope, ESA/NASA
2017-12-08
NASA image acquired August 29, 2012 1:57 a.m EDT Annotated view here: bit.ly/RsFT9Y Hurricane Isaac lit up by moonlight as it spins over the city of New Orleans, La. at 1:57 am central daylight savings time the morning of August 29, 2012. The Suomi National Polar-orbiting Partnership (NPP) satellite captured these images with its Visible Infrared Imaging Radiometer Suite (VIIRS). The "day-night band" of VIIRS detects light in a range of wavelengths from green to near-infrared and uses light intensification to enable the detection of dim signals. Suomi NPP is the result of a partnership between NASA, the National Oceanic and Atmospheric Administration and the Department of Defense. Image Credit: NASA/NOAA, Earth Observatory NASA Earth Observatory image by Jesse Allen and Robert Simmon, using VIIRS Day Night Band data. Credit: NASA Earth Observatory NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Wireless sensor and actuator networks for lighting energy efficiency and user satisfaction
NASA Astrophysics Data System (ADS)
Wen, Yao-Jung
Buildings consume more than one third of the primary energy generated in the U.S., and lighting alone accounts for approximately 30% of the energy usage in commercial buildings. As the largest electricity consumer of all building electrical systems, lighting harbors the greatest potential for energy savings in the commercial sector. Fifty percent of current energy consumption could be reduced with energy-efficient lighting management strategies. While commercial products do exist, they are poorly received due to exorbitant retrofitting cost and unsatisfactory performance. As a result, most commercial buildings, especially legacy buildings, have not taken advantage of the opportunity to generate savings from lighting. The emergence of wireless sensor and actuator network (WSAN) technologies presents an alternative that circumvents costly rewiring and promises better performance than existing commercial lighting systems. The goal of this dissertation research is to develop a framework for wireless-networked lighting systems with increased cost effectiveness, energy efficiency, and user satisfaction. This research is realized through both theoretical developments and implementations. The theoretical research aims at developing techniques for harnessing WSAN technologies to lighting hardware and control strategies. Leveraging redundancy, a sensor validation and fusion algorithm is developed for extracting pertinent lighting information from the disturbance-prone desktop-mounted photosensors. An adaptive sensing strategy optimizes the timing of data acquisition and power-hungry wireless transmission of sensory feedback in real-time lighting control. Exploiting the individual addressability of wireless-enabled luminaires, a lighting optimization algorithm is developed to create the optimal lighting that minimizes energy usage while satisfying occupants' diverse lighting preferences. The wireless-networked lighting system was implemented and tested in a number of real-life settings. A human subject study conducted in a private office concluded that the research system was competitive with the commercial lighting system with much fewer retrofitting requirements. The system implemented in a shared-space office realized a self-configuring mesh network with wireless photosensors and light actuators, and demonstrated a 50% energy savings and increased performance when harvesting daylight through windows is possible. The cost analysis revealed a reasonable payback period after the system is optimized for commercialization and confirms the marketing feasibility.
Development of new methodologies for evaluating the energy performance of new commercial buildings
NASA Astrophysics Data System (ADS)
Song, Suwon
The concept of Measurement and Verification (M&V) of a new building continues to become more important because efficient design alone is often not sufficient to deliver an efficient building. Simulation models that are calibrated to measured data can be used to evaluate the energy performance of new buildings if they are compared to energy baselines such as similar buildings, energy codes, and design standards. Unfortunately, there is a lack of detailed M&V methods and analysis methods to measure energy savings from new buildings that would have hypothetical energy baselines. Therefore, this study developed and demonstrated several new methodologies for evaluating the energy performance of new commercial buildings using a case-study building in Austin, Texas. First, three new M&V methods were developed to enhance the previous generic M&V framework for new buildings, including: (1) The development of a method to synthesize weather-normalized cooling energy use from a correlation of Motor Control Center (MCC) electricity use when chilled water use is unavailable, (2) The development of an improved method to analyze measured solar transmittance against incidence angle for sample glazing using different solar sensor types, including Eppley PSP and Li-Cor sensors, and (3) The development of an improved method to analyze chiller efficiency and operation at part-load conditions. Second, three new calibration methods were developed and analyzed, including: (1) A new percentile analysis added to the previous signature method for use with a DOE-2 calibration, (2) A new analysis to account for undocumented exhaust air in DOE-2 calibration, and (3) An analysis of the impact of synthesized direct normal solar radiation using the Erbs correlation on DOE-2 simulation. Third, an analysis of the actual energy savings compared to three different energy baselines was performed, including: (1) Energy Use Index (EUI) comparisons with sub-metered data, (2) New comparisons against Standards 90.1-1989 and 90.1-2001, and (3) A new evaluation of the performance of selected Energy Conservation Design Measures (ECDMs). Finally, potential energy savings were also simulated from selected improvements, including: minimum supply air flow, undocumented exhaust air, and daylighting.
Occupant-responsive optimal control of smart facade systems
NASA Astrophysics Data System (ADS)
Park, Cheol-Soo
Windows provide occupants with daylight, direct sunlight, visual contact with the outside and a feeling of openness. Windows enable the use of daylighting and offer occupants a outside view. Glazing may also cause a number of problems: undesired heat gain/loss in winter. An over-lit window can cause glare, which is another major complaint by occupants. Furthermore, cold or hot window surfaces induce asymmetric thermal radiation which can result in thermal discomfort. To reduce the potential problems of window systems, double skin facades and airflow window systems have been introduced in the 1970s. They typically contain interstitial louvers and ventilation openings. The current problem with double skin facades and airflow windows is that their operation requires adequate dynamic control to reach their expected performance. Many studies have recognized that only an optimal control enables these systems to truly act as active energy savers and indoor environment controllers. However, an adequate solution for this dynamic optimization problem has thus far not been developed. The primary objective of this study is to develop occupant responsive optimal control of smart facade systems. The control could be implemented as a smart controller that operates the motorized Venetian blind system and the opening ratio of ventilation openings. The objective of the control is to combine the benefits of large windows with low energy demands for heating and cooling, while keeping visual well-being and thermal comfort at an optimal level. The control uses a simulation model with an embedded optimization routine that allows occupant interaction via the Web. An occupant can access the smart controller from a standard browser and choose a pre-defined mode (energy saving mode, visual comfort mode, thermal comfort mode, default mode, nighttime mode) or set a preferred mode (user-override mode) by moving preference sliders on the screen. The most prominent feature of these systems is the capability of dynamically reacting to the environmental input data through real-time optimization. The proposed occupant responsive optimal control of smart facade systems could provide a breakthrough in this under-developed area and lead to a renewed interest in smart facade systems.
Gongruttananun, N
2011-12-01
In total, 120 Thai-native pullets (Gallus domesticus) aged 18 wk were housed in floor pens, located in a conventional open-sided shed under natural daylight (12L:12D) and randomly divided into 3 groups; Groups 1 (DF) and 2 (DR) were reared under natural daylight and supplemented with fluorescent or red light, respectively, whereas group 3 (R) was maintained in light-controlled pens and exposed only to red light. The red light was produced by light-emitting diodes. All treatments were provided with 16 h of light per day (16L:8D) during a 26-wk egg-laying period, and there were 4 replicate pens of 10 hens for each treatment. Photostimulation of these light sources was initiated at 18 wk of age and subsequent effects on reproductive performance were observed during the experimental period. Morphological characteristics of the eyes and eggshell microstructure were examined at the end of the study. Feed and water were provided ad libitum. There were no significant differences in BW, feed intake, egg weight, egg quality, or mortality rate due to the treatment. Pullets in the R and DR treatment groups commenced egg production significantly earlier than those in the DF treatment group. In early-season egg production (0-8 wk), cumulative egg number was significantly (P < 0.05) higher for the R treatment (25.9 eggs/hen) than for the DR (20.9) and DF (19.5) treatment groups. No significant differences in total egg production per hen occurred among the treatment groups. At 2 wk following photostimulation, hens in the R treatment group had significantly (P < 0.05) higher serum estradiol concentrations compared with hens in the other treatment groups. Neither eggshell structure nor eye morphology was affected by the treatments. It was concluded that the spectrum of red light did not affect live performance, egg production, egg quality, eggshell microstructure, or eye morphology of Thai-native hens, except for in accelerating sexual development. The light-emitting diode lighting system would be beneficial for energy savings and the reduction of rearing costs.
SPiRiT Scoring Through Self-Assessment Charrettes
2004-09-01
Continued) 0 Max 17 5.C5 Indoor Chemical and Pollutant Source Control 1 5.C6 Controllability of Systems 2 5.C7 Thermal Comfort 2 5.C8...Pollutant Source Control 1 5.C6 Controllability of Systems 2 5.C7 Thermal Comfort 2 5.C8 Daylight and Views 2 5.C9 Acoustic Environment...1 5.C6 Controllability of Systems 2 5.C7 Thermal Comfort 2 5.C8 Daylight and Views 2 5.C9 Acoustic Environment /Noise Control 1 5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, Gregory; Mistrick, Ph.D., Richard; Lee, Eleanor
2011-01-21
We describe two methods which rely on bidirectional scattering distribution functions (BSDFs) to model the daylighting performance of complex fenestration systems (CFS), enabling greater flexibility and accuracy in evaluating arbitrary assemblies of glazing, shading, and other optically-complex coplanar window systems. Two tools within Radiance enable a) efficient annual performance evaluations of CFS, and b) accurate renderings of CFS despite the loss of spatial resolution associated with low-resolution BSDF datasets for inhomogeneous systems. Validation, accuracy, and limitations of the methods are discussed.
Yin, Haibo; Chen, Xiaofang; Hou, Rujing; Zhu, Huijuan; Li, Shiqing; Huo, Yuning; Li, Hexing
2015-09-16
Ag/BiOBr film coated on the glass substrate was synthesized by a solvothermal method and a subsequent photoreduction process. Such a Ag/BiOBr film was then adhered to a hollow rotating disk filled with long-afterglow phosphor inside the chamber. The Ag/BiOBr film exhibited high photocatalytic activity for organic pollutant degradation owing to the improved visible-light harvesting and the separation of photoinduced charges. The long-afterglow phosphor could absorb the excessive daylight and emit light around 488 nm, activating the Ag/BiOBr film to realize round-the-clock photocatalysis. Because the Ag nanoparticles could extend the light absorbance of the Ag/BiOBr film to wavelengths of around 500 nm via a surface plasma resonance effect, they played a key role in realizing photocatalysis induced by long-afterglow phosphor.
American Society of Nuclear Cardiology
... Society of Nuclear Cardiology Career Center Search for jobs. Post a resume or job. Member Login Enter Forgot your password? Meetings & Events ... Extended! Missed ASNC2017? Save $100 -Order Meeting On Demand by Oct. 31 Wednesday, October 25, 2017 admin ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sesonske, A.
1980-08-01
Detailed core management arrangements are developed requiring four operating cycles for the transition from present three-batch loading to an extended burnup four-batch plan for Zion-1. The ARMP code EPRI-NODE-P was used for core modeling. Although this work is preliminary, uranium and economic savings during the transition cycles appear of the order of 6 percent.
Geothermal Power/Oil & Gas Coproduction Opportunity
DOE Office of Scientific and Technical Information (OSTI.GOV)
DOE
2012-02-01
Coproduced geothermal resources can deliver near-term energy savings, diminish greenhouse gas emissions, extend the economic life of oil and gas fields, and profitably utilize oil and gas field infrastructure. This two-pager provides an overview of geothermal coproduced resources.
The effect of ambient lighting on Laser Doppler Imaging of a standardized cutaneous injury model
Pham, Alan Chuong Q; Hei, Erik La; Harvey, John G; Holland, Andrew JA
2017-01-01
Objective: The aim of this study was to investigate the potential confounding effects of four different types of ambient lighting on the results of Laser Doppler Imaging (LDI) of a standardized cutaneous injury model. Methods: After applying a mechanical stimulus to the anterior forearm of a healthy volunteer and inducing a wheal and arteriolar flare (the Triple response), we used a Laser Doppler Line Scanner (LDLS) to image the forearm under four different types of ambient lighting: light-emitting-diode (LED), compact fluorescent lighting (CFL), halogen, daylight, and darkness as a control. A spectrometer was used to measure the intensity of light energy at 785 nm, the wavelength used by the scanner for measurement under each type of ambient lighting. Results: Neither the LED nor CFL bulbs emitted detectable light energy at a wavelength of 785 nm. The color-based representation of arbitrary perfusion unit (APU) values of the Triple response measured by the scanner was similar between darkness, LED, and CFL light. Daylight emitted 2 mW at 785 nm, with a slight variation tending more towards lower APU values compared to darkness. Halogen lighting emitted 6 mW of light energy at 785 nm rendering the color-based representation impossible to interpret. Conclusions: Halogen lighting and daylight have the potential to confound results of LDI of cutaneous injuries whereas LED and CFL lighting did not. Any potential sources of daylight should be reduced and halogen lighting completely covered or turned off prior to wound imaging. PMID:29348978
Hunting influences the diel patterns in habitat selection by northern pintails Anas acuta
Casazza, Michael L.; Coates, Peter S.; Miller, Michael R.; Overton, Cory T.; Yparraguirre, Daniel R.
2012-01-01
Northern pintail Anas acuta (hereafter pintail) populations wintering within Suisun Marsh, a large estuarine managed wetland near San Francisco Bay, California,USA, have declined markedly over the last four decades. The reasons for this decline are unclear. Information on how hunting and other factors influence the selection of vegetation types and sanctuaries would be beneficial to manage pintail populations in SuisunMarsh. During 1991-1993, we radio-marked and relocated female pintails (individuals: N = 203, relocations: N = 7,688) within Suisun Marsh to investigate habitat selection during the non-breeding months (winter). We calculated selection ratios for different vegetation types and for sanctuaries, and examined differences in those ratios between hunting season (i.e. hunting and non-hunting), age (hatchyear and after-hatch-year), and time of day (daylight or night hours). We found that diel patterns in selection were influenced by hunting disturbance. For example, prior to the hunting season and during daylight hours, pintails selected areas dominated by brass buttons Cotula coronopifolia, a potentially important food source, usually outside of sanctuary boundaries. However, during the hunting season, pintails did not select brass buttons during daylight hours, but instead highly selected permanent pools, mostly within sanctuaries. Also, during the hunting season, pintails showed strong selection for brass buttons at night. Sanctuaries provided more area of permanent water pools than within hunting areas and appeared to function as important refugia during daylight hours of the hunting season. Wildlife managers should encourage large protected permanent pools adjacent to hunted wetlands to increase pintail numbers within wetland environments and responsibly benefit hunting opportunities while improving pintail conservation.
A spatially augmented reality sketching interface for architectural daylighting design.
Sheng, Yu; Yapo, Theodore C; Young, Christopher; Cutler, Barbara
2011-01-01
We present an application of interactive global illumination and spatially augmented reality to architectural daylight modeling that allows designers to explore alternative designs and new technologies for improving the sustainability of their buildings. Images of a model in the real world, captured by a camera above the scene, are processed to construct a virtual 3D model. To achieve interactive rendering rates, we use a hybrid rendering technique, leveraging radiosity to simulate the interreflectance between diffuse patches and shadow volumes to generate per-pixel direct illumination. The rendered images are then projected on the real model by four calibrated projectors to help users study the daylighting illumination. The virtual heliodon is a physical design environment in which multiple designers, a designer and a client, or a teacher and students can gather to experience animated visualizations of the natural illumination within a proposed design by controlling the time of day, season, and climate. Furthermore, participants may interactively redesign the geometry and materials of the space by manipulating physical design elements and see the updated lighting simulation. © 2011 IEEE Published by the IEEE Computer Society
Sampling strategies for radio-tracking coyotes
Smith, G.J.; Cary, J.R.; Rongstad, O.J.
1981-01-01
Ten coyotes radio-tracked for 24 h periods were most active at night and moved little during daylight hours. Home-range size determined from radio-locations of 3 adult coyotes increased with the number of locations until an asymptote was reached at about 35-40 independent day locations or 3 6 nights of hourly radio-locations. Activity of the coyote did not affect the asymptotic nature of the home-range calculations, but home-range sizes determined from more than 3 nights of hourly locations were considerably larger than home-range sizes determined from daylight locations. Coyote home-range sizes were calculated from daylight locations, full-night tracking periods, and half-night tracking periods. Full- and half-lnight sampling strategies involved obtaining hourly radio-locations during 12 and 6 h periods, respectively. The half-night sampling strategy was the best compromise for our needs, as it adequately indexed the home-range size, reduced time and energy spent, and standardized the area calculation without requiring the researcher to become completely nocturnal. Sight tracking also provided information about coyote activity and sociability.
Light-scattering properties of a Venetian blind slat used for daylighting applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nilsson, Annica M.; Jonsson, Jacob C.
2010-12-15
The low cost, simplicity, and aesthetic appearance of external and internal shading devices, make them commonly used for daylighting and glare-control applications. Shading devices, such as Venetian blinds, screens, and roller shades, generally exhibit light scattering and/or light redirecting properties. This requires the bi-directional scattering distribution function (BSDF) of the material to be known in order to accurately predict the daylight distribution and energy flow through the fenestration system. Acquiring the complete BSDF is not a straightforward task, and to complete the process it is often required that a model is used to complement the measured data. In this project,more » a Venetian blind slat with a white top surface and a brushed aluminum bottom surface was optically characterized. A goniophotometer and an integrating sphere spectrophotometer were used to determine the angle resolved and hemispherical reflectance of the sample, respectively. The acquired data were fitted to a scattering model providing one Lambertian and one angle dependent description of the surface properties. These were used in combination with raytracing to obtain the complete BSDFs of the Venetian blind system. (author)« less
NASA Astrophysics Data System (ADS)
Amado, L.; Osma, G.; Villamizar, R.
2016-07-01
This paper presents the modelling of lighting behaviour of a hybrid lighting system - HLS in inner spaces for tropical climate. HLS aims to mitigate the problem of high electricity consumption used by artificial lighting in buildings. These systems integrate intelligently the daylight and artificial light through control strategies. However, selection of these strategies usually depends on expertise of designer and of available budget. In order to improve the selection process of the control strategies, this paper analyses the Electrical Engineering Building (EEB) case, initially modelling of lighting behaviour is established for the HLS of a classroom and an office. This allows estimating the illuminance level of the mixed lighting in the space, and energy consumption by artificial light according to different lighting control techniques, a control strategy based on occupancy and a combination of them. The model considers the concept of Daylight Factor (DF) for the estimating of daylight illuminance on the work plane for tropical climatic conditions. The validation of the model was carried out by comparing the measured and model-estimated indoor illuminances.
Determinants of Colour Constancy and the Blue Bias
Gegenfurtner, Karl
2017-01-01
We investigated several sensory and cognitive determinants of colour constancy across 40 illumination hues. In the first experiment, we measured colour naming for the illumination and for the colour induced by the illumination on the colorimetric grey. Results confirmed that the induced colours are approximately complementary to the colour of the illumination. In the second experiment, we measured colour constancy using achromatic adjustments. Average colour constancy was perfect under the blue daylight illumination and decreased in colour directions away from the blue daylight illumination due to undershooting and a strong blue bias. Apart from this blue bias, colour constancy was not related to illumination discrimination and to chromatic detection measured previously with the same setup and stimuli. We also observed a strong negative relationship between the degree of colour constancy and the consensus of naming the illumination colour. Constancy coincided with a low naming consensus, in particular because bluish illumination colours were sometimes seen as achromatic. Blue bias and category consensus alone explained >68%, and all determinants together explained >94% of the variance of achromatic adjustments. These findings suggest that colour constancy is optimised for blue daylight. PMID:29348910
A compact free space quantum key distribution system capable of daylight operation
NASA Astrophysics Data System (ADS)
Benton, David M.; Gorman, Phillip M.; Tapster, Paul R.; Taylor, David M.
2010-06-01
A free space quantum key distribution system has been demonstrated. Consideration has been given to factors such as field of view and spectral width, to cut down the deleterious effect from background light levels. Suitable optical sources such as lasers and RCLEDs have been investigated as well as optimal wavelength choices, always with a view to building a compact and robust system. The implementation of background reduction measures resulted in a system capable of operating in daylight conditions. An autonomous system was left running and generating shared key material continuously for over 7 days.
Will farmers save water? A theoretical analysis of groundwater conservation policies
USDA-ARS?s Scientific Manuscript database
The development of agricultural irrigation systems has generated significant increases in food production and farm income. However, unplanned and unconstrained groundwater use could also cause serious consequences. To extend the economic life of groundwater, water conservation issues have become the...
Integrating UAS Flocking Operations with Formation Drag Reduction
2014-03-01
20 Figure 8: Close vs . Extended Formation Flight (FF) Comparison (Ning 2011, 12)......... 24 Figure 9: Basic Guidance Control...and Near Misses vs . Flock Size... vs . Longitudinal Spacing............................ 52 Figure 21: Flock Cumulative Fuel Savings vs . Distance Between Turns
Hogewoning, Sander W; Douwstra, Peter; Trouwborst, Govert; van Ieperen, Wim; Harbinson, Jeremy
2010-03-01
Plant responses to the light spectrum under which plants are grown affect their developmental characteristics in a complicated manner. Lamps widely used to provide growth irradiance emit spectra which are very different from natural daylight spectra. Whereas specific responses of plants to a spectrum differing from natural daylight may sometimes be predictable, the overall plant response is generally difficult to predict due to the complicated interaction of the many different responses. So far studies on plant responses to spectra either use no daylight control or, if a natural daylight control is used, it will fluctuate in intensity and spectrum. An artificial solar (AS) spectrum which closely resembles a sunlight spectrum has been engineered, and growth, morphogenesis, and photosynthetic characteristics of cucumber plants grown for 13 d under this spectrum have been compared with their performance under fluorescent tubes (FTs) and a high pressure sodium lamp (HPS). The total dry weight of the AS-grown plants was 2.3 and 1.6 times greater than that of the FT and HPS plants, respectively, and the height of the AS plants was 4-5 times greater. This striking difference appeared to be related to a more efficient light interception by the AS plants, characterized by longer petioles, a greater leaf unfolding rate, and a lower investment in leaf mass relative to leaf area. Photosynthesis per leaf area was not greater for the AS plants. The extreme differences in plant response to the AS spectrum compared with the widely used protected cultivation light sources tested highlights the importance of a more natural spectrum, such as the AS spectrum, if the aim is to produce plants representative of field conditions.
Home-Based Primary Care: Beyond Extension of the Independence at Home Demonstration.
Rotenberg, James; Kinosian, Bruce; Boling, Peter; Taler, George
2018-04-01
The Independence at Home (IAH) Demonstration Year 2 results confirmed that the first-year savings were 10 times as great as those of the pioneer accountable care organizations during their initial 2 years. We update projected savings from nationwide conversion of the IAH demonstration, incorporating Year 2 results and improving attribution of IAH-qualified (IAH-Q) Medicare beneficiaries to home-based primary care (HBPC) practices. Applying IAH qualifying criteria to beneficiaries in the Medicare 5% claims file, the effect of expanding HBPC to the 2.4 million IAH-Q beneficiaries is projected using various growth rates. Total 10-year system-wide savings (accounting for IAH implementation but before excluding shared savings) range from $2.6 billion to $27.8 billion, depending on how many beneficiaries receive HBPC on conversion to a Medicare benefit, mix of clinical practice success, and growth rate of IAH practices. Net projected savings to the Centers for Medicare and Medicaid Services (CMS) after routine billing for IAH services and distribution of shared savings ranges from $1.8 billion to $10.9 billion. If aligning IAH with other advanced alternative payment models achieved at least 35% penetration of the eligible population in 10 years, CMS savings would exceed savings with the current IAH design and HBPC growth rate. If the demonstration were simply extended 2 years with a beneficiary cap of 50,000 instead of 15,000 (as currently proposed), CMS would save an additional $46 million. The recent extension of IAH, a promising person-centered CMS program for managing medically complex and frail elderly adults, offers the chance to evaluate modifications to promote more rapid HBPC growth. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.
Acceleration of Radiance for Lighting Simulation by Using Parallel Computing with OpenCL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuo, Wangda; McNeil, Andrew; Wetter, Michael
2011-09-06
We report on the acceleration of annual daylighting simulations for fenestration systems in the Radiance ray-tracing program. The algorithm was optimized to reduce both the redundant data input/output operations and the floating-point operations. To further accelerate the simulation speed, the calculation for matrix multiplications was implemented using parallel computing on a graphics processing unit. We used OpenCL, which is a cross-platform parallel programming language. Numerical experiments show that the combination of the above measures can speed up the annual daylighting simulations 101.7 times or 28.6 times when the sky vector has 146 or 2306 elements, respectively.
Optoelectronic aid for patients with severely restricted visual fields in daylight conditions
NASA Astrophysics Data System (ADS)
Peláez-Coca, María Dolores; Sobrado-Calvo, Paloma; Vargas-Martín, Fernando
2011-11-01
In this study we evaluated the immediate effectiveness of an optoelectronic visual field expander in a sample of subjects with retinitis pigmentosa suffering from a severe peripheral visual field restriction. The aid uses the augmented view concept and provides subjects with visual information from outside their visual field. The tests were carried out in daylight conditions. The optoelectronic aid comprises a FPGA (real-time video processor), a wide-angle mini camera and a transparent see-through head-mounted display. This optoelectronic aid is called SERBA (Sistema Electro-óptico Reconfigurable de Ayuda para Baja Visión). We previously showed that, without compromising residual vision, the SERBA system provides information about objects within an area about three times greater on average than the remaining visual field of the subjects [1]. In this paper we address the effects of the device on mobility under daylight conditions with and without SERBA. The participants were six subjects with retinitis pigmentosa. In this mobility test, better results were obtained when subjects were wearing the SERBA system; specifically, both the number of contacts with low-level obstacles and mobility errors decreased significantly. A longer training period with the device might improve its usefulness.
Diurnal trends in methylmercury concentration in a wetland adjacent to Great Salt Lake, Utah, USA
Naftz, D.L.; Cederberg, J.R.; Krabbenhoft, D.P.; Beisner, K.R.; Whitehead, J.; Gardberg, J.
2011-01-01
A 24-h field experiment was conducted during July 2008 at a wetland on the eastern shore of Great Salt Lake (GSL) to assess the diurnal cycling of methylmercury (MeHg). Dissolved (<0.45??m) MeHg showed a strong diurnal variation with consistently decreasing concentrations during daylight periods and increasing concentrations during non-daylight periods. The proportion of MeHg relative to total Hg in the water column consistently decreased with increasing sunlight duration, indicative of photodegradation. During the field experiment, measured MeHg photodegradation rates ranged from 0.02 to 0.06ngL-1h-1. Convective overturn of the water column driven by nighttime cooling of the water surface was hypothesized as the likely mechanism to replace the MeHg in the water column lost via photodegradation processes. A hydrodynamic model of the wetland successfully simulated convective overturn of the water column during the field experiment. Study results indicate that daytime monitoring of selected wetlands surrounding GSL may significantly underestimate the MeHg content in the water column. Wetland managers should consider practices that maximize the photodegradation of MeHg during daylight periods. ?? 2011.
Periodic catatonia with long-term treatment: a case report.
Chen, Ruei-An; Huang, Tiao-Lai
2017-09-29
Periodic catatonia has long been a challenging diagnosis and there are no absolute guidelines for treatment when precipitating factors are also unclear. We report a schizophrenia patient with periodic catatonia with a 15-year treatment course. A possible correlation between decreased daylight exposure and periodic attacks has been observed. We describe a 49-year-old woman with periodic catatonia associated with schizophrenia with 15 years of follow-up. The patient was treated with the antipsychotics risperidone, haloperidol, loxapine and quetiapine, but catatonia still relapsed once per year during the first few years of her disease course. The treatment was consequently been switched to clozapine due to fluctuated psychotic illness, and a longer duration of remittance was achieved. Lorazepam-diazepam protocol was used for rapid relief of catatonic symptoms, and was able to significantly shorten the duration of the symptoms. In addition, we observed a possible correlation between catatonic episodes and decreased daylight exposure during the 15-year duration. Successful treatment of acute periodic catatonia was achieved with a lorazepam-diazepam protocol, and the patient remained in remission for a longer duration under clozapine treatment. Besides, the possibility of decreased daylight exposure acting as a precipitating factor was observed during our 15 years of follow-up.
Lafer-Sousa, Rosa; Liu, Yang O; Lafer-Sousa, Luis; Wiest, Michael C; Conway, Bevil R
2012-05-01
Colors defined by the two intermediate directions in color space, "orange-cyan" and "lime-magenta," elicit the same spatiotemporal average response from the two cardinal chromatic channels in the lateral geniculate nucleus (LGN). While we found LGN functional magnetic resonance imaging (fMRI) responses to these pairs of colors were statistically indistinguishable, primary visual cortex (V1) fMRI responses were stronger to orange-cyan. Moreover, linear combinations of single-cell responses to cone-isolating stimuli of V1 cone-opponent cells also yielded stronger predicted responses to orange-cyan over lime-magenta, suggesting these neurons underlie the fMRI result. These observations are consistent with the hypothesis that V1 recombines LGN signals into "higher-order" mechanisms tuned to noncardinal color directions. In light of work showing that natural images and daylight samples are biased toward orange-cyan, our findings further suggest that V1 is adapted to daylight. V1, especially double-opponent cells, may function to extract spatial information from color boundaries correlated with scene-structure cues, such as shadows lit by ambient blue sky juxtaposed with surfaces reflecting sunshine. © 2012 Optical Society of America
Daylight coloring for monochrome infrared imagery
NASA Astrophysics Data System (ADS)
Gabura, James
2015-05-01
The effectiveness of infrared imagery in poor visibility situations is well established and the range of applications is expanding as we enter a new era of inexpensive thermal imagers for mobile phones. However there is a problem in that the counterintuitive reflectance characteristics of various common scene elements can cause slowed reaction times and impaired situational awareness-consequences that can be especially detrimental in emergency situations. While multiband infrared sensors can be used, they are inherently more costly. Here we propose a technique for adding a daylight color appearance to single band infrared images, using the normally overlooked property of local image texture. The simple method described here is illustrated with colorized images from the visible red and long wave infrared bands. Our colorizing process not only imparts a natural daylight appearance to infrared images but also enhances the contrast and visibility of otherwise obscure detail. We anticipate that this colorizing method will lead to a better user experience, faster reaction times and improved situational awareness for a growing community of infrared camera users. A natural extension of our process could expand upon its texture discerning feature by adding specialized filters for discriminating specific targets.
Student Understanding of Time in an Introductory Astronomy Laboratory
NASA Astrophysics Data System (ADS)
Traxler, A. L.; Batuski, D. J.; Comins, N. F.; Thompson, J. R.
2005-09-01
The astronomy lab at the University of Maine consists of discrete weekly lessons in which students work in small groups. Individual pretests and post-tests accompany each lesson. The lesson studied here covers the topic of time, including sidereal time, Apparent Solar Time, and time zones. The pretest consists of four multiple-choice questions, which are also administered after instruction as a post-test. In the fall 2004 semester, the pretest was rewritten to focus on some major conceptual components of the lab, while the lesson materials were not modified from previous years. Examination of class performance (n = 96) revealed no significant improvements in score from pre- to post-lesson. In the spring 2005 semester, the lesson was altered to incorporate the Starry Night software for simulating the sky instead of the celestial sphere models previously used. The goal of the change was to give students a more interactive environment for completing the laboratory exercise, which was otherwise altered as little as possible. Data from the spring semester show some gains on the pre/post-test questions covering sidereal time and Daylight Savings Time. Results to date have informed planned modifications to the lesson. A. L. T. was supported during this research by the University of Maine through a Provost Fellowship.
Performance effects of mounting a helmet-mounted display on the ANVIS mount of the HGU-56P helmet
NASA Astrophysics Data System (ADS)
Harding, Thomas H.; Martin, John S.; Rash, Clarence E.
2006-05-01
The U.S. Army, under the auspices of the Air Warrior Product Office, is developing a modular helmet-mounted display (HMD) for four aircraft series within its helicopter fleet. A design consideration is mounting the HMDs to the HGU- 56P Aviator's Night Vision Imaging System (ANVIS) mount. This particular mount is being considered, presumably due to its inherent cost savings, as the mount is already part of the helmet. Mounting the HMD in this position may have consequences for the daylight performance of these HMDs, as well as increasing the forward weight of the HMD. The latter would have consequences for helmet weight and center-of-mass biodynamic issues. Calculations were made of the increased luminance needed as a consequence of mounting the HMD in front of an HGU-56P tinted visor as opposed to mounting it behind the visor. By mounting in front of the helmet's visor, the HMD's light output will be filtered as light coming from the outside world. Special consideration then would have to be given to the HMD's light source selection process, as not to select a source that would differentially reduce luminance by a mounted visor (e.g., laser protection visors) compared to the ambient light in the aviator's field-of-view.
Recent progress in millimeter-wave sensor system capabilities for enhanced (synthetic) vision
NASA Astrophysics Data System (ADS)
Hellemann, Karlheinz; Zachai, Reinhard
1999-07-01
Weather- and daylight independent operation of modern traffic systems is strongly required for an optimized and economic availability. Mainly helicopters, small aircraft and military transport aircraft operating frequently close to the ground have a need for effective and cost-effective Enhanced Vision sensors. The technical progress in sensor technology and processing speed offer today the possibility for new concepts to be realized. Derived from this background the paper reports on the improvements which are under development within the HiVision program at DaimlerChrysler Aerospace. A sensor demonstrator based on FMCW radar technology with high information update-rate and operating in the mm-wave band, has been up-graded to improve performance and fitted to fly on an experimental base. The results achieved so far demonstrate the capability to produce a weather independent enhanced vision. In addition the demonstrator has been tested on board a high- speed ferry at the Baltic sea, because fast vessels have a similar need for weather-independent operation and anti- collision measures. In the future one sensor type may serve both 'worlds' and help ease and save traffic. The described demonstrator fills up the technology gap between optical sensors (Infrared) and standard pulse radars with its specific features such as high speed scanning and weather penetration with the additional benefit of cost-effectiveness.
Innovative design of parabolic reflector light guiding structure
NASA Astrophysics Data System (ADS)
Whang, Allen J.; Tso, Chun-Hsien; Chen, Yi-Yung
2008-02-01
Due to the idea of everlasting green architecture, it is of increasing importance to guild natural light into indoors. The advantages are multifold - to have better color rendering index, excellent energy savings from environments viewpoints and make humans more healthy, etc. Our search is to design an innovative structure, to convert outdoor sun light impinges on larger surfaces, into near linear light beam sources, later convert this light beam into near point sources which enters the indoor spaces then can be used as lighting sources indoors. We are not involved with the opto-electrical transformation, to the guild light into to the building, to perform the illumination, as well as the imaging function. Because non-imaging optics, well known for apply to the solar concentrators, that can use non-imaging structures to fulfill our needs, which can also be used as energy collectors in solar energy devices. Here, we have designed a pair of large and small parabolic reflector, which can be used to collect daylight and change area from large to small. Then we make a light-guide system that is been designed by us use of this parabolic reflector to guide the collection light, can pick up the performance for large surface source change to near linear source and a larger collection area.
Control algorithms for dynamic windows for residential buildings
Firlag, Szymon; Yazdanian, Mehrangiz; Curcija, Charlie; ...
2015-09-30
This study analyzes the influence of control algorithms for dynamic windows on energy consumption, number of hours of retracted shades during daylight and shade operations. Five different control algorithms - heating/cooling, simple rules, perfect citizen, heat flow and predictive weather were developed and compared. The performance of a typical residential building was modeled with EnergyPlus. The program Widow was used to generate a Bi-Directional Distribution Function (BSDF) for two window configurations. The BSDF was exported to EnergyPlus using the IDF file format. The EMS feature in EnergyPlus was used to develop custom control algorithms. The calculations were made for fourmore » locations with diverse climate. The results showed that: (a) use of automated shading with proposed control algorithms can reduce the site energy in the range of 11.6-13.0%; in regard to source (primary) energy in the range of 20.1-21.6%, (b) the differences between algorithms in regard to energy savings are not high, (c) the differences between algorithms in regard to number of hours of retracted shades are visible, (e) the control algorithms have a strong influence on shade operation and oscillation of shade can occur, (d) additional energy consumption caused by motor, sensors and a small microprocessor in the analyzed case is very small.« less
Advanced Cogeneration Technology Economic Optimization Study (ACTEOS)
NASA Technical Reports Server (NTRS)
Nanda, P.; Ansu, Y.; Manuel, E. H., Jr.; Price, W. G., Jr.
1980-01-01
The advanced cogeneration technology economic optimization study (ACTEOS) was undertaken to extend the results of the cogeneration technology alternatives study (CTAS). Cost comparisons were made between designs involving advanced cogeneration technologies and designs involving either conventional cogeneration technologies or not involving cogeneration. For the specific equipment cost and fuel price assumptions made, it was found that: (1) coal based cogeneration systems offered appreciable cost savings over the no cogeneration case, while systems using coal derived liquids offered no costs savings; and (2) the advanced cogeneration systems provided somewhat larger cost savings than the conventional systems. Among the issues considered in the study included: (1) temporal variations in steam and electric demands; (2) requirements for reliability/standby capacity; (3) availability of discrete equipment sizes; (4) regional variations in fuel and electricity prices; (5) off design system performance; and (6) separate demand and energy charges for purchased electricity.
Feeding ecology of long-tailed ducks Clangula hyemalis wintering on the Nantucket Shoals
White, Timothy P.; Veit, Richard R.; Perry, Matthew C.
2009-01-01
A substantial proportion, perhaps 30%, of the North American breeding population of Long-tailed Ducks (Clangula hyemalis) winter in the vicinity of Nantucket Island, Massachusetts. These birds spend the night on Nantucket Sound and commute during daylight hours to the Nantucket Shoals, which extend about 65 km offshore from the southeastern corner of Nantucket. Strip transects done from a single-engine plane in 1997 and 1998 indicated that Long-tailed Ducks foraged over the shallower (<= 20 m depth) portions of the Nantucket Shoals, up to 70 km offshore. Diet analyses of ten birds collected in February 1999 and five in December 2006 showed that they fed principally (106.6 +/- 42.0 individuals per crop) on Gammarus annulatus, a pelagic amphipod that often forms large aggregations, and is consumed by several species of fish and marine mammals. Our findings emphasize the importance of conservation of the Nantucket Shoals and the prevention of oil spills or other potentially harmful accidents.
Aurora Australis as seen from STS-62
1994-03-05
STS062-58-025 (4-18 March) --- This photo shows the aurora australis or souther lights. The multi-hued shafts of light, extending upward to 200 miles above the earth's surface, are caused by beams of energetic electrons colliding with the oxygen and nitrogen in the earth's upper atmosphere. The strong red glow occurs at the highest altitude where the air is least dense and composed mostly of oxygen. At lower altitudes, the greater density favors the green color, also produced by atomic oxygen. Sometimes at the bottom (the lowest altitude of the aurora) a pink border is produced by nitrogen. The aurora usually can be seen only in Arctic regions. However, because of the tilt of the magnetic axis of the space shuttle mission orbits. One of these regions is over eastern North American, and the second one is south of Australia. Since most shuttle launches occur in daytime, the North American region is in daylight, and the only auroras that can be seen are usually in the Southern Hemisphere.
Negative obstacle detection by thermal signature
NASA Technical Reports Server (NTRS)
Matthies, Larry; Rankin, A.
2003-01-01
Detecting negative obstacles (ditches, potholes, and other depressions) is one of the most difficult problems in perception for autonomous, off-road navigation. Past work has largely relied on range imagery, because that is based on the geometry of the obstacle, is largely insensitive to illumination variables, and because there have not been other reliable alternatives. However, the visible aspect of negative obstacles shrinks rapidly with range, making them impossible to detect in time to avoid them at high speed. To relive this problem, we show that the interiors of negative obstacles generally remain warmer than the surrounding terrain throughout the night, making thermal signature a stable property for night-time negative obstacle detection. Experimental results to date have achieved detection distances 45% greater by using thermal signature than by using range data alone. Thermal signature is the first known observable with potential to reveal a deep negative obstacle without actually seeing far into it. Modeling solar illumination has potential to extend the usefulness of thermal signature through daylight hours.
Apparent minification in an imaging display under reduced viewing conditions.
Meehan, J W
1993-01-01
When extended outdoor scenes are imaged with magnification of 1 in optical, electronic, or computer-generated displays, scene features appear smaller and farther than in direct view. This has been shown to occur in various periscopic and camera-viewfinder displays outdoors in daylight. In four experiments it was found that apparent minification of the size of a planar object at a distance of 3-9 m indoors occurs in the viewfinder display of an SLR camera both in good light and in darkness with only the luminous object visible. The effect is robust and survives changes in the relationship between object luminance in the display and in direct view and occurs in the dark when subjects have no prior knowledge of room dimensions, object size or object distance. The results of a fifth experiment suggest that the effect is an instance of reduced visual size constancy consequent on elimination of cues for size, which include those for distance.
Automatic Generation of Test Oracles - From Pilot Studies to Application
NASA Technical Reports Server (NTRS)
Feather, Martin S.; Smith, Ben
1998-01-01
There is a trend towards the increased use of automation in V&V. Automation can yield savings in time and effort. For critical systems, where thorough V&V is required, these savings can be substantial. We describe a progression from pilot studies to development and use of V&V automation. We used pilot studies to ascertain opportunities for, and suitability of, automating various analyses whose results would contribute to V&V. These studies culminated in the development of an automatic generator of automated test oracles. This was then applied and extended in the course of testing an Al planning system that is a key component of an autonomous spacecraft.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-23
... Suicide Prevention Lifeline Form. Frequency: Annually. Affected public: Non-Profit Institutions. SAMHSA is... hotline networks are preventing suicides and saving lives. SAMHSA cannot reasonably comply with the normal... emergency request is to extend data collection activities of the Monitoring of National Suicide Prevention...
Providing Demonstrable Return-on-Investment for Organisational Learning and Training
ERIC Educational Resources Information Center
Elliott, Michael; Dawson, Ray; Edwards, Janet
2009-01-01
Purpose: The aim of this paper is to present a holistic approach to training, that clearly demonstrates cost savings with improved effectiveness and efficiencies that are aligned to business objectives. Design/methodology/approach: Extending Kirkpatrick's evaluation framework with Phillips's return-on-investment (ROI) concepts, the paper conveys a…
Psychology in the Prescription Era: Building a Firewall between Marketing and Science
ERIC Educational Resources Information Center
Antonuccio, David O.; Danton, William G.; McClanahan, Terry Michael
2003-01-01
The pharmaceutical industry has contributed to many life-saving innovations in medicine and has become one of the most successful industries in the world. As a result, pharmaceutical industry financial and marketing influences extend to federal regulatory agencies, professional organizations, medical journals, continuing medical education,…
Code of Federal Regulations, 2012 CFR
2012-01-01
... with § 195.41. (d) Automated teller machine (ATM) means an automated, unstaffed banking facility owned...) Motor vehicle loan, which is a consumer loan extended for the purchase of and secured by a motor vehicle... means a savings association that offers only a narrow product line (such as credit card or motor vehicle...
Code of Federal Regulations, 2014 CFR
2014-01-01
... with § 195.41. (d) Automated teller machine (ATM) means an automated, unstaffed banking facility owned...) Motor vehicle loan, which is a consumer loan extended for the purchase of and secured by a motor vehicle... means a savings association that offers only a narrow product line (such as credit card or motor vehicle...
Code of Federal Regulations, 2013 CFR
2013-01-01
... with § 195.41. (d) Automated teller machine (ATM) means an automated, unstaffed banking facility owned...) Motor vehicle loan, which is a consumer loan extended for the purchase of and secured by a motor vehicle... means a savings association that offers only a narrow product line (such as credit card or motor vehicle...
12 CFR 561.12 - Consumer credit.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 5 2011-01-01 2011-01-01 false Consumer credit. 561.12 Section 561.12 Banks... AFFECTING ALL SAVINGS ASSOCIATIONS § 561.12 Consumer credit. The term consumer credit means credit extended... real estate and chattel liens secured by mobile homes and leases of personal property to consumers that...
Influence of pH and light on the stability of some antioxidants.
Racine, P
1981-06-01
Summary Many organic molecules can be oxidized in the presence of oxygen. Light and traces of heavy metal ions catalyse the process of oxidation. The addition of a very small quantity of antioxidant to alcoholic perfumes and cosmetic bases is often made to retard auto-oxidations. Among the parameters which could influence the efficiency of an antioxidant, its intrinsic stability should be considered in the medium to be protected. This stability might conceivably be influenced by the pH, the presence of light, heavy metal ions and microorganisms. In this study we have concentrated on the role played by the first two factors. To eliminate a possible interference by the last two, analytical grades reagents together with chelators and high proof (80% v/v) hydroalcoholic solutions have been used. The antioxidants tested were: BHT, BHA, ethyl gallate, 2, carboxy-6, hydroxy, 2, 5, 7, 8, tetramethyl chroman (Trolox C(R)) and D-L-alpha-tocopherol. Solutions of 0.5 mmol/kg of each antioxidant were prepared in 80% v/v hydroalcoholic solutions and the pH adjusted with citric acid and potassium hydroxyde or hydrochloric acid. The pH extended from 2.5 to 10 and thus largely covers the pH range of cosmetic products. Of each solution, 100ml were kept in hermetically closed 125ml white glass bottles stored at room temperature (22 +/- 2 degrees C) and kept in the dark or exposed to the diffuse daylight of the laboratory. The antioxidants concentrations were determined by linear sweep voltametry on gold or glassy carbon electrodes. Significant differences in behaviour were observed. BHA and BHT are stable regardless of light and pH except at high pH (=9). Ethyl gallate vanishes rapidly in alkaline, neutral and even weakly acid pH independently of the presence of light. Trolox C and D-L-alpha-tocopherol demonstrated a marked influence of the presence of daylight and of the pH.
Growth/reflectance model interface for wheat and corresponding model
NASA Technical Reports Server (NTRS)
Suits, G. H.; Sieron, R.; Odenweller, J.
1984-01-01
The use of modeling to explore the possibility of discovering new and useful crop condition indicators which might be available from the Thematic Mapper and to connect these symptoms to the biological causes in the crop is discussed. A crop growth model was used to predict the day to day growth features of the crop as it responds biologically to the various environmental factors. A reflectance model was used to predict the character of the interaction of daylight with the predicted growth features. An atmospheric path radiance was added to the reflected daylight to simulate the radiance appearing at the sensor. Finally, the digitized data sent to a ground station were calculated. The crop under investigation is wheat.
Improving daylight in mosques using domes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alturki, I.; Schiler, M.; Boyajian, Y.
1996-10-01
This paper studies the possibilities for improving daylight in mosques by measuring the illumination level under various domes in an old mosque ``Mosque of Guzelce Hasan Bey in Hayrabolu`` using an architectural physical model. The illumination level under the domes were tested under three different cases: a dome without openings (the original building), a dome with a central opening, and a dome with openings around the base. It was found that a dome with openings around the base brings an evenly distributed light all over the prayer hall during the critical hours of 12:00 p.m. and 3:00 p.m. In addition,more » it improves the quality and quantity of light.« less
Design of an interferometric system for piston measurements in segmented primary mirrors
NASA Astrophysics Data System (ADS)
Arasa, Josep; Laguarta, Ferran; Pizarro, Carlos; Tomas, Nuria; Pinto, Agusti
2000-10-01
Recently, telescopes with segmented primary mirrors are becoming increasingly popular due to their ability of achieving large apertures without the inconveniences caused by the fabrication and handling of monolithic surfaces with 8m (or over) in diameter. The difference in position of each pair of adjacent segments along the local normal of their interface (called piston hereafter), however, needs to be precisely measured in order to provide a diffraction- limited image. If a system yielding the nanometric accuracy required in piston measurements worked in daylight hours, the resultant saving in observation time would be an important advance on a majority of the state-of-the-art piston measurement systems. An interferometric piston measurement instrument accomplishing such objectives has been designed starting from the usual Michelson configuration at the CD6 (Terrassa, Spain), and its final test has been carried out in the test workbench of the Instituto de Astrofisica de Canarias (IAC, Canary Islands, Spain). Its optical layout relies on projecting the reference arm of the interferometer onto one of the segments of the pair considered, along the direction of the local normal to the surface while the measurement arm is projected onto the interface which divides the pair of segments considered. The field of view and its illumination are calculated to be equivalent in both segments. The lateral shift of the fringes in both interferograms determines the piston error present. A combination of monochromatic and white light is used, in order to remove the (lambda) /2 phase ambiguities present in piston measurements without losing the required resolution in the measurement. In this paper, the optical design of this interferometric piston measurement instrument will be presented. The particular configuration used in the interferometer, the implementation of an imaging system allowing to see both the interface of the segments and the interference fringes, the effect of the extension of the source and the use of both monochromatic and whit light will be discussed. A detailed study of the wavefront errors embedded in the wavefront at different stages of the interferometer is performed. The analysis shows the validity of the design of the instrument, and some experimental results obtained at the test workbench are provided to demonstrate the ability of the instrument to perform nanometric piston measurements under daylight conditions.
Fleischman, Ross J.; Lundquist, Mark; Jui, Jonathan; Newgard, Craig D.; Warden, Craig
2014-01-01
Objective To derive and validate a model that accurately predicts ambulance arrival time that could be implemented as a Google Maps web application. Methods This was a retrospective study of all scene transports in Multnomah County, Oregon, from January 1 through December 31, 2008. Scene and destination hospital addresses were converted to coordinates. ArcGIS Network Analyst was used to estimate transport times based on street network speed limits. We then created a linear regression model to improve the accuracy of these street network estimates using weather, patient characteristics, use of lights and sirens, daylight, and rush-hour intervals. The model was derived from a 50% sample and validated on the remainder. Significance of the covariates was determined by p < 0.05 for a t-test of the model coefficients. Accuracy was quantified by the proportion of estimates that were within 5 minutes of the actual transport times recorded by computer-aided dispatch. We then built a Google Maps-based web application to demonstrate application in real-world EMS operations. Results There were 48,308 included transports. Street network estimates of transport time were accurate within 5 minutes of actual transport time less than 16% of the time. Actual transport times were longer during daylight and rush-hour intervals and shorter with use of lights and sirens. Age under 18 years, gender, wet weather, and trauma system entry were not significant predictors of transport time. Our model predicted arrival time within 5 minutes 73% of the time. For lights and sirens transports, accuracy was within 5 minutes 77% of the time. Accuracy was identical in the validation dataset. Lights and sirens saved an average of 3.1 minutes for transports under 8.8 minutes, and 5.3 minutes for longer transports. Conclusions An estimate of transport time based only on a street network significantly underestimated transport times. A simple model incorporating few variables can predict ambulance time of arrival to the emergency department with good accuracy. This model could be linked to global positioning system data and an automated Google Maps web application to optimize emergency department resource use. Use of lights and sirens had a significant effect on transport times. PMID:23865736
What Is the Reference? An Examination of Alternatives to the Reference Sources Used in IES TM-30-15
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.
A study was undertaken to document the role of the reference illuminant in the IES TM-30-15 method for evaluating color rendition. TM-30-15 relies on a relative reference scheme; that is, the reference illuminant and test source always have the same correlated color temperature (CCT). The reference illuminant is a Planckian radiator, model of daylight, or combination of those two, depending on the exact CCT of the test source. Three alternative reference schemes were considered: 1) either using all Planckian radiators or all daylight models; 2) using only one of ten possible illuminants (Planckian, daylight, or equal energy), regardless of themore » CCT of the test source; 3) using an off-Planckian reference illuminant (i.e., a source with a negative Duv). No reference scheme is inherently superior to another, with differences in metric values largely a result of small differences in gamut shape of the reference alternatives. While using any of the alternative schemes is more reasonable in the TM-30-15 evaluation framework than it was with the CIE CRI framework, the differences still ultimately manifest only as changes in interpretation of the results. References are employed in color rendering measures to provide a familiar point of comparison, not to establish an ideal source.« less
Decreased retinal sensitivity in depressive disorder: a controlled study.
Berman, G; Muttuvelu, D; Berman, D; Larsen, J I; Licht, R W; Ledolter, J; Kardon, R H
2018-03-01
To compare pupil responses in depressed patients with a seasonal pattern, depressed patients without a seasonal pattern and healthy controls as a function of daylight hours on the testing day. Patients suffering from a major depressive episode were included in wintertime. The pupil light reflex was measured at inclusion and in the following summer using a binocular pupillometer. A protocol of low (1 lux) and high (400 lux) intensity red and blue lights was used to assess rod, cone and melanopsin-containing intrinsic photosensitive retinal ganglion cell input to the pupil reflex. The mean group pupil responses associated with a melanopsin-mediated sustained pupil response at 400 lux blue light were significantly reduced in the depressed subjects (N = 39) as compared to the healthy controls (N = 24) (P = 0.023). Across all groups, a reduction in number of daylight hours was significantly associated with a reduction in sustained pupil response (P = 0.007). All groups showed an equal effect of daylight hours on the melanopsin-mediated sustained pupil response. The melanopsin-mediated sustained pupil contraction to offset of high-intensity blue light is reduced in depressed patients. These results further emphasize the interaction of light exposure with depression. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Modified optical fiber daylighting system with sunlight transportation in free space.
Vu, Ngoc-Hai; Pham, Thanh-Tuan; Shin, Seoyong
2016-12-26
We present the design, optical simulation, and experiment of a modified optical fiber daylighting system (M-OFDS) for indoor lighting. The M-OFDS is comprised of three sub-systems: concentration, collimation, and distribution. The concentration part is formed by coupling a Fresnel lens with a large-core plastic optical fiber. The sunlight collected by the concentration sub-system is propagated in a plastic optical fiber and then collimated by the collimator, which is a combination of a parabolic mirror and a convex lens. The collimated beam of sunlight travels in free space and is guided to the interior by directing flat mirrors, where it is diffused uniformly by a distributor. All parameters of the system are calculated theoretically. Based on the designed system, our simulation results demonstrated a maximum optical efficiency of 71%. The simulation results also showed that sunlight could be delivered to the illumination destination at distance of 30 m. A prototype of the M-OFDS was fabricated, and preliminary experiments were performed outdoors. The simulation results and experimental results confirmed that the M-OFDS was designed effectively. A large-scale system constructed by several M-OFDSs is also proposed. The results showed that the presented optical fiber daylighting system is a strong candidate for an inexpensive and highly efficient application of solar energy in buildings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Tengfang; Piette, Mary Ann
2004-08-05
The original scope of work was to obtain and analyze existing and emerging data in four states: California, Florida, New York, and Wisconsin. The goal of this data collection was to deliver a baseline database or recommendations for such a database that could possibly contain window and daylighting features and energy performance characteristics of Kindergarten through 12th grade (K-12) school buildings (or those of classrooms when available). In particular, data analyses were performed based upon the California Commercial End-Use Survey (CEUS) databases to understand school energy use, features of window glazing, and availability of daylighting in California K-12 schools. Themore » outcomes from this baseline task can be used to assist in establishing a database of school energy performance, assessing applications of existing technologies relevant to window and daylighting design, and identifying future R&D needs. These are in line with the overall project goals as outlined in the proposal. Through the review and analysis of this data, it is clear that there are many compounding factors impacting energy use in K-12 school buildings in the U.S., and that there are various challenges in understanding the impact of K-12 classroom energy use associated with design features of window glazing and skylight. First, the energy data in the existing CEUS databases has, at most, provided the aggregated electricity and/or gas usages for the building establishments that include other school facilities on top of the classroom spaces. Although the percentage of classroom floor area in schools is often available from the databases, there is no additional information that can be used to quantitatively segregate the EUI for classroom spaces. In order to quantify the EUI for classrooms, sub-metering of energy usage by classrooms must be obtained. Second, magnitudes of energy use for electricity lighting are not attainable from the existing databases, nor are the lighting levels contributed by artificial lighting or daylight. It is impossible to reasonably estimate the lighting energy consumption for classroom areas in the sample of schools studied in this project. Third, there are many other compounding factors that may as well influence the overall classroom energy use, e.g., ventilation, insulation, system efficiency, occupancy, control, schedules, and weather. Fourth, although we have examined the school EUI grouped by various factors such as climate zones, window and daylighting design features from the California databases, no statistically significant associations can be identified from the sampled California K-12 schools in the current California CEUS. There are opportunities to expand such analyses by developing and including more powerful CEUS databases in the future. Finally, a list of parameters is recommended for future database development and for use of future investigation in K-12 classroom energy use, window and skylight design, and possible relations between them. Some of the key parameters include: (1) Energy end use data for lighting systems, classrooms, and schools; (2) Building design and operation including features for windows and daylighting; and (3) Other key parameters and information that would be available to investigate overall energy uses, building and systems design, their operation, and services provided.« less
NASA Astrophysics Data System (ADS)
Roggemann, M.; Soehnel, G.; Archer, G.
Atmospheric turbulence degrades the resolution of images of space objects far beyond that predicted by diffraction alone. Adaptive optics telescopes have been widely used for compensating these effects, but as users seek to extend the envelopes of operation of adaptive optics telescopes to more demanding conditions, such as daylight operation, and operation at low elevation angles, the level of compensation provided will degrade. We have been investigating the use of advanced wave front reconstructors and post detection image reconstruction to overcome the effects of turbulence on imaging systems in these more demanding scenarios. In this paper we show results comparing the optical performance of the exponential reconstructor, the least squares reconstructor, and two versions of a reconstructor based on the stochastic parallel gradient descent algorithm in a closed loop adaptive optics system using a conventional continuous facesheet deformable mirror and a Hartmann sensor. The performance of these reconstructors has been evaluated under a range of source visual magnitudes and zenith angles ranging up to 70 degrees. We have also simulated satellite images, and applied speckle imaging, multi-frame blind deconvolution algorithms, and deconvolution algorithms that presume the average point spread function is known to compute object estimates. Our work thus far indicates that the combination of adaptive optics and post detection image processing will extend the useful envelope of the current generation of adaptive optics telescopes.
Teaching New Keynesian Open Economy Macroeconomics at the Intermediate Level
ERIC Educational Resources Information Center
Bofinger, Peter; Mayer, Eric; Wollmershauser, Timo
2009-01-01
For the open economy, the workhorse model in intermediate textbooks still is the Mundell-Fleming model, which basically extends the investment and savings, liquidity preference and money supply (IS-LM) model to open economy problems. The authors present a simple New Keynesian model of the open economy that introduces open economy considerations…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-15
... Federal Motor Vehicle Theft Prevention Standard was extended to include all passenger cars and... Vehicle Theft Prevention Standard (Part 541), all passenger cars, and multipurpose passenger vehicles with..., 565 and 567. Part 541 The Motor Vehicle Information and Cost Savings Act was amended by the Anti-Car...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-03
... extension for three years, without revision of the following report: 1. Report title: Consolidated Bank... Banking Investments Held for an Extended Period. Agency form number: FR Y-12, FR Y12A, respectively. OMB...: Bank holding companies (BHCs), financial holding companies (FHCs) and savings and loan holding...
Building an efficient supply chain.
Scalise, Dagmara
2005-08-01
Realizing at last that supply chain management can produce efficiencies and save costs, hospitals are beginning to adopt practices from other industries, such as the concept of extended supply chains, to improve product flow. They're also investing in enterprise planning resource software, radio frequency identification and other technologies, using quality data to drive standardization and streamlining processes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
A new steel jacket design by Aker Engineering A.S. suitable for use in construction of platforms in 50m of water results in a 47% saving of steel as compared to conventional designs. Modifications of the design extends its usefulness to 150m of water with steel savings of 20 to 30%. A node design is used, and all nodes except the top and bottom ones are identical. The basic shape is a tetrahedron and all steel members are cylindrical with the same outside diameter but with different wall thickness where more or less strength is needed. Other advantages of this designmore » are ease and speed of fabrication. The tetratower is compared with the more conventional 8-legged jacket. (BLM)« less
Solar collector with altitude tracking
Barak, Amitzur Z.
1977-01-01
A device is provided for turning a solar collector about an east-west horizontal axis so that the collector is tilted toward the sun as the EWV altitude of the sun varies each day. It includes one or more heat responsive elements and a shading means aligned so that within a range of EWV altitudes of the sun during daylight hours the shading means shades the element or elements while during the rest of the daylight hours the elements or elements are heated by the sun to assume heated, stable states. Mechanical linkage between the collector and the element is responsive to the states of the element or elements to tilt the collector in accordance with variations in the EWV altitude of the sun.
[Current recommendations for deceleration of myopia progression].
Lagrèze, W A; Joachimsen, L; Schaeffel, F
2017-01-01
Epidemiologic data demonstrate a rise in myopia prevalence. Therefore interventions to reduce the risk of myopia and its progression are needed and increasingly often asked for. Systematic literature search via PubMed in MEDLINE. Myopia progression can be reduced by the following means which are listed according to their efficacy: (1) Atropine eye drops low dosed to avoid clinically relevant side effects, (2) optical means aiming at the correction of peripheral hyperopic defocus, e. g., multifocal contact lenses, and (3) increased daylight exposure. Daylight exposure reduces the risk of incident myopia. Children should be advised to spend sufficient time outdoors, especially before and in primary school. Myopia progression can be effectively attenuated by low-dose topical atropine and multifocal contact lenses.
Hurricane Celia off the Pacific Coast of Mexico
2004-07-23
Hurricane Celia as observed by NASA's spaceborne Atmospheric Infrared Sounder (AIRS). This image shows Celia on July 23 in visible light, as you would perceive it from space. Located in the eastern north Pacific Ocean off the coast of Mexico, Celia's winds have now dissipated to highs of 40 mph. Celia was the first hurricane of the eastern north Pacific season. Figure 1 is a daylight snapshot taken on July 19; Celia as tropical storm, winds at 50mph. Figure 2 is a daylight snapshot taken on July 21; Celia has a small eye with an 80-90% closed eyewall; sustained winds at 75mph with gusts reaching 92mph; Celia is upgraded to hurricane status. http://photojournal.jpl.nasa.gov/catalog/PIA00438
Development of an automated energy audit protocol for office buildings
NASA Astrophysics Data System (ADS)
Deb, Chirag
This study aims to enhance the building energy audit process, and bring about reduction in time and cost requirements in the conduction of a full physical audit. For this, a total of 5 Energy Service Companies in Singapore have collaborated and provided energy audit reports for 62 office buildings. Several statistical techniques are adopted to analyse these reports. These techniques comprise cluster analysis and development of prediction models to predict energy savings for buildings. The cluster analysis shows that there are 3 clusters of buildings experiencing different levels of energy savings. To understand the effect of building variables on the change in EUI, a robust iterative process for selecting the appropriate variables is developed. The results show that the 4 variables of GFA, non-air-conditioning energy consumption, average chiller plant efficiency and installed capacity of chillers should be taken for clustering. This analysis is extended to the development of prediction models using linear regression and artificial neural networks (ANN). An exhaustive variable selection algorithm is developed to select the input variables for the two energy saving prediction models. The results show that the ANN prediction model can predict the energy saving potential of a given building with an accuracy of +/-14.8%.
Retail clinic utilization associated with lower total cost of care.
Sussman, Andrew; Dunham, Lisette; Snower, Kristen; Hu, Min; Matlin, Olga S; Shrank, William H; Choudhry, Niteesh K; Brennan, Troyen
2013-04-01
To better understand the impact of retail clinic use on a patient's annual total cost of care. A propensity score matched-pair, cohort design was used to analyze healthcare spending patterns among CVS Caremark employees in the year following a visit to a MinuteClinic, the retail clinics inside CVS pharmacies. De-identified medical and pharmacy claims for CVS Caremark employees and their dependents who received care at a retail clinic between June 1, 2009, and May 31, 2010, were matched to those of subjects who received care elsewhere. High-dimensional propensity score and greedy matching techniques were used to create a 1-to-1 matched cohort that was analyzed using generalized linear regression models. Individuals using a retail clinic had a lower total cost of care (-$262; 95% confidence interval, -$510 to -$31; P = .025) in the year following their clinic visit than individuals who received care in other settings. This savings was primarily due to lower medical expenses at physicians' offices ($77 savings, P = .008) and hospital inpatient care ($121 savings, P = .049). The 6022 retail clinic users also had 142 (12%) fewer emergency department visits (P = .01), though this was not related to significant cost savings. This study found that retail clinic use was associated with lower overall total cost of care compared with that at alternative sites. Savings may extend beyond the retail clinic visit itself to other types of medical utilization.
Extended electrode technique. [gas metal arc welding of metal plates
NASA Technical Reports Server (NTRS)
Schaper, V. D.; Pollack, A.
1972-01-01
The extended electrode technique is a unique welding process which utilizes manual gas-metal-arc (GMAW) semi-automatic equipment and close, square butt joints to effectively produce a weld. The technique takes advantage of the resistance heating of the electode extension to effect the root pass. Weldments as large as 72-X30-X2-inch have been fabricated with this technique under normal shipyard welding conditions. Mechanical properties and explosion bulge tests indicate that satisfactory results are obtained with this process. Potential savings of approximately 50 percent can be achieved in flat welding and repair of heavy structural steel members.
Forgotten but not gone: savings for pictures and words in long-term memory.
MacLeod, C M
1988-04-01
Five experiments examined the relearning of words, simple line-drawing pictures, and complex photographic pictures after retention intervals of 1 to 10 weeks. For those items that were neither recalled nor recognized, the identical item was relearned better than an unrelated control item, as measured by a recall test following relearning. This relearning advantage in recall held for all three classes of material and extended to the cross-modality case (i.e., picture-word and word-picture) and the same-referent case (i.e., two pictures of the same object). However, recognition tests of relearning failed to detect this same relearning advantage for apparently forgotten items. Taken together, these findings conflict with the existing account of savings. Most fundamental, the classic argument that relearning serves a trace-strengthening function is undetermined by the observed recall-recognition contrast. An alternative explanation of savings is suggested wherein relearning assists retrieval of information, thereby affecting recall in particular.
Reducing power usage on demand
NASA Astrophysics Data System (ADS)
Corbett, G.; Dewhurst, A.
2016-10-01
The Science and Technology Facilities Council (STFC) datacentre provides large- scale High Performance Computing facilities for the scientific community. It currently consumes approximately 1.5MW and this has risen by 25% in the past two years. STFC has been investigating leveraging preemption in the Tier 1 batch farm to save power. HEP experiments are increasing using jobs that can be killed to take advantage of opportunistic CPU resources or novel cost models such as Amazon's spot pricing. Additionally, schemes from energy providers are available that offer financial incentives to reduce power consumption at peak times. Under normal operating conditions, 3% of the batch farm capacity is wasted due to draining machines. By using preempt-able jobs, nodes can be rapidly made available to run multicore jobs without this wasted resource. The use of preempt-able jobs has been extended so that at peak times machines can be hibernated quickly to save energy. This paper describes the implementation of the above and demonstrates that STFC could in future take advantage of such energy saving schemes.
Watkins, David A; Olson, Zachary D; Verguet, Stéphane; Nugent, Rachel A; Jamison, Dean T
2016-02-01
The South African Government recently set targets to reduce cardiovascular disease (CVD) by lowering salt consumption. We conducted an extended cost-effectiveness analysis (ECEA) to model the potential health and economic impacts of this salt policy. We used surveys and epidemiologic studies to estimate reductions in CVD resulting from lower salt intake. We calculated the average out-of-pocket (OOP) cost of CVD care, using facility fee schedules and drug prices. We estimated the reduction in OOP expenditures and government subsidies due to the policy. We estimated public and private sector costs of policy implementation. We estimated financial risk protection (FRP) from the policy as (1) cases of catastrophic health expenditure (CHE) averted or (2) cases of poverty averted. We also performed a sensitivity analysis. We found that the salt policy could reduce CVD deaths by 11%, with similar health gains across income quintiles. The policy could save households US$ 4.06 million (2012) in OOP expenditures (US$ 0.29 per capita) and save the government US$ 51.25 million in healthcare subsidies (US$ 2.52 per capita) each year. The cost to the government would be only US$ 0.01 per capita; hence, the policy would be cost saving. If the private sector food reformulation costs were passed on to consumers, food expenditures would increase by <0.2% across all income quintiles. Preventing CVD could avert 2400 cases of CHE or 2000 cases of poverty yearly. Our results were sensitive to baseline CVD mortality rates and the cost of treatment. We conclude that, in addition to health gains, population salt reduction can have positive economic impacts-substantially reducing OOP expenditures and providing FRP, particularly for the middle class. The policy could also provide large government savings on health care. © The Author 2015. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
NASA Astrophysics Data System (ADS)
Maiwald, M.; Müller, A.; Sumpf, B.
2017-02-01
In-situ shifted excitation Raman difference spectroscopy (SERDS) experiments are presented using a portable sensor system. Key elements of this system are an in-house developed handheld probe with an implemented dual-wavelength diode laser at 785 nm. An optical power of 120 mW is achieved ex probe. Raman experiments are carried out in the laboratory for qualification using polystyrene as test sample. Here, a shot-noise limited signal-to-noise ratio (SNR) of 120 is achieved. Stability tests were performed and show a stable position of the Raman line under study within 0.1 cm-1 and a stable Raman intensity better +/- 2% mainly limited by shot noise interference. SERDS experiments are carried out in an apple orchard for demonstration. Green apple leafs are used as test samples. The Raman spectra show huge background interferences by fluorescence and ambient daylight which almost obscure Raman signals from green leafs. The selected excitation power is 50 mW and the exposure time is 0.2 s to avoid detector saturation. SERDS efficiently separates the Raman signals from fluorescence and daylight contributions and generates an 11-fold improvement of the signal-to-background noise with respect to the measured Raman signals. The results demonstrate the capability of the portable SERDS system and enable rapid in-situ and undisturbed Raman investigations under daylight conditions.
Marra, Kayla; LaRochelle, Ethan P; Chapman, M Shane; Hoopes, P Jack; Lukovits, Karina; Maytin, Edward V; Hasan, Tayyaba; Pogue, Brian W
2018-04-16
Daylight-mediated photodynamic therapy (d-PDT) as a treatment for actinic keratosis (AK) is an increasingly common technique due to a significant reduction in pain, leading to better patient tolerability. While past studies have looked at different light sources and delivery methods, this study strives to provide equivalent PpIX-weighted light doses with the hypothesis that artificial light sources could be equally as effective as natural sunlight if their PpIX-weighted fluences were equalized. Normal mouse skin was used as the model to compare blue LED light, metal halide white light and natural sunlight, with minimal incubation time between topical ALA application and the onset of light delivery. A total PpIX-weighted fluence of 20 J eff cm -2 was delivered over 2 h, and the efficacy of response was quantified using three acute bioassays for PDT damage: PpIX photobleaching, Stat3 crosslinking and quantitative histopathology. These bioassays indicated blue light was slightly inferior to both sunlight and white light, but that the latter two were not significantly different. The results suggest that metal halide white light could be a reasonable alternative to daylight PDT, which should allow a more controlled treatment that is independent of weather and yet should have similar response rates with limited pain during treatment. © 2018 The American Society of Photobiology.
Performance analysis of FET microwave devices by use of extended spectral-element time-domain method
NASA Astrophysics Data System (ADS)
Sheng, Yijun; Xu, Kan; Wang, Daoxiang; Chen, Rushan
2013-05-01
The extended spectral-element time-domain (SETD) method is employed to analyse field effect transistor (FET) microwave devices. In order to impose the contribution of the FET microwave devices into the electromagnetic simulation, the SETD method is extended by introducing a lumped current term into the vector Helmholtz equation. The change of currents on each lumped component can be expressed by the change of voltage via corresponding models of equivalent circuit. The electric fields around the lumped component must be influenced by the change of voltage on each lumped component, and vice versa. So a global coupling about the EM-circuit can be built directly. The fully explicit solving scheme is maintained in this extended SETD method and the CPU time can be saved spontaneously. Three practical FET microwave devices are analysed in this article. The numerical results demonstrate the ability and accuracy of this method.
Extended duration Orbiter life support definition
NASA Technical Reports Server (NTRS)
Kleiner, G. N.; Thompson, C. D.
1978-01-01
Extending the baseline seven-day Orbiter mission to 30 days or longer and operating with a solar power module as the primary source for electrical power requires changes to the existing environmental control and life support (ECLS) system. The existing ECLS system imposes penalties on longer missions which limit the Orbiter capabilities and changes are required to enhance overall mission objectives. Some of these penalties are: large quantities of expendables, the need to dump or store large quantities of waste material, the need to schedule fuel cell operation, and a high landing weight penalty. This paper presents the study ground rules and examines the limitations of the present ECLS system against Extended Duration Orbiter mission requirements. Alternate methods of accomplishing ECLS functions for the Extended Duration Orbiter are discussed. The overall impact of integrating these options into the Orbiter are evaluated and significant Orbiter weight and volume savings with the recommended approaches are described.
Code of Federal Regulations, 2011 CFR
2011-01-01
... innovative designs, materials, and equipment such as daylighting, passive solar heating, and heat recovery... select the fuel source for the HVAC systems, service hot water, and process loads from available...
... or produced by the skin when exposed to sunlight. Lack of vitamin D production by the skin ... who: Live in climates with little exposure to sunlight Must stay indoors Work indoors during the daylight ...
New Trends in Educational Lighting Systems.
ERIC Educational Resources Information Center
Murphy, Peter
2001-01-01
Explores technological trends for improving campus lighting, including the use of direct-indirect suspended fluorescent lighting, suspended linear lighting, high-efficiency optical systems, and occupancy and daylight sensors. (GR)
Salazar, Vielka L; Stoddard, Philip K
2008-03-01
To understand the evolution of sexually dimorphic communication signals, we must quantify their costs, including their energetic costs, the regulation of these costs, and the difference between the costs for the sexes. Here, we provide the first direct measurements of the relative energy expended on electric signals and show for the focal species Brachyhypopomus pinnicaudatus that males spend a significantly greater proportion of their total energy budget on signal generation (11-22%) compared with females (3%). Both sexes significantly reduce the energy spent on electric signals during daylight hours through circadian modulation of the amplitude, duration and repetition rate of the electric signal, but this effect is more marked in males. Male body condition predicted the energy spent on electric signals (R(2)=0.75). The oxygen consumed by males for signal production closely paralleled the product of the electric signal's waveform area (R(2)=0.99) and the discharge rate (R(2)=0.59), two signal parameters that can be assessed directly by conspecifics. Thus the electric communication signal of males carries the information to reveal their body condition to prospective mates and competing males. Because the electric signal constitutes a significant fraction of the energy budget, energy savings, along with predation avoidance, provides an adaptive basis for the production of circadian rhythms in electric signals.
NASA Astrophysics Data System (ADS)
Faherty, Jacqueline; Rodriguez, D.
2013-01-01
There are rare times in astronomy when a celestial event, visible in broad daylight, can be used to measure a fundamental parameter and inspire a globe full of school age students. The June 5th/6th transit of Venus was one such event. In celebration, nine astronomy postdocs from the Chilean mainland traveled to Easter Island to lead a series of astronomy outreach activities over three days, culminating in a transit-viewing event. Our team dubbed "Equipo Hetu'u" or "Team Star" in the Rapa Nui (Easter Island native) language spent two days giving astronomy talks and doing hands-on demonstrations at the Museo Antropologico P. Sebastian Englert. In the final day-and-a-half leading up to the transit, we visited the science classes in the majority of the schools on the island, in order to spread the message about the once-in-a-lifetime transit event, highlighting how we planned on using it to measure the distance to the Sun. We estimate over 25% 1500 people) of this remote island participated in one or more of our organized activities. Our experience with this project is an excellent lesson on how to organize, lead, and fully execute a major outreach endeavor that inspires hundreds with minimal resources (save the spectacular event provided by the cosmos).
ERIC Educational Resources Information Center
Kennedy, Mike
2002-01-01
Reviews ways that schools can provide effective indoor learning environments by paying attention to the following areas: daylighting, acoustics, space allocation, technology implementation, ergonomics, maintenance, indoor air quality, safety, restrooms, and roofing. (GR)
... may use a variety of instruments, shine bright lights directly at your eyes and request that you ... exam is complete, as daylight or other bright lights may be uncomfortable or cause blurred vision. Also, ...
Hatamleh, Muhanad M; Watts, David C
2011-02-01
To evaluate the effect of three commonly used bond primers on the bending strength of glass fibers and their bond strength to maxillofacial silicone elastomer after 360 hours of accelerated daylight aging. Eighty specimens were fabricated by embedding resin-impregnated fiber bundles (1.5-mm diameter, 20-mm long) into maxillofacial silicone elastomer M511 (Cosmesil). Twenty fiber bundles served as control and did not receive surface treatment with primers, whereas the remaining 60 fibers were treated with three primers (n = 20): G611 (Principality Medical), A-304 (Factor II), and A-330-Gold (Factor II). Forty specimens were dry stored at room temperature (23 ± 1°C) for 24 hours, and the remaining specimens were aged using an environmental chamber under accelerated exposure to artificial daylight for 360 hours. The aging cycle included continuous exposure to quartz-filtered visible daylight (irradiance 760 W/m(2) ) under an alternating weathering cycle (wet for 18 minutes, dry for 102 minutes). Pull-out tests were performed to evaluate bond strength between fiber bundles and silicone using a universal testing machine at 1 mm/min crosshead speed. A 3-point bending test was performed to evaluate the bending strength of the fiber bundles. One-way Analysis of Variance (ANOVA), Bonferroni post hoc test, and an independent t-test were carried out to detect statistical significances (p < 0.05). Mean (SD) values of maximum pull-out forces (N) before aging for groups: no primer, G611, A-304, A-330-G were: 13.63 (7.45), 20.44 (2.99), 22.06 (6.69), and 57.91 (10.15), respectively. All primers increased bond strength in comparison to control specimens (p < 0.05). Primer A-330-G showed the greatest increase among all primers (p < 0.05); however, bonding degraded after aging (p < 0.05), and pull-out forces were 13.58 (2.61), 6.17 (2.89), 6.95 (2.61), and 11.72 (3.03). Maximum bending strengths of fiber bundles at baseline increased after treatment with primers and light aging in comparison with control specimens (p < 0.05), and were in the range of 917.72 to 1095.25 and 1124.06 to 1596.68 MPa at both baseline and after 360 hours aging (p < 0.05). The use of A-330-G primer in conjunction with silicone Cosmesil M511 produced the greatest bond strength for silicone-glass fiber surfaces at baseline; however, bond strength was significantly degraded after accelerated daylight aging. Treatment with primer and accelerated daylight aging increased bending strength of glass fibers. © 2011 by The American College of Prosthodontists.
ERIC Educational Resources Information Center
Filler, Martin
1979-01-01
The new energy consciousness has led to a thorough reevaluation of how artificial lighting can be used wisely, while other researchers have explored the potential of daylighting as an alternative interior light source. (Author/MLF)
2001 Mars Odyssey THEMIS: Thermophysics at a New Local Time
NASA Astrophysics Data System (ADS)
Hamilton, V. E.; Christensen, P. R.
2017-12-01
During its sixth extended mission, the 2001 Mars Odyssey transitioned to a new, rarely-seen, post-sunset (morning daylight) local time designed to reduce stress on the spacecraft. Since then, Thermal Emission Imaging System (THEMIS) observations have provided an unprecedented opportunity to investigate dynamic phenomena in the atmosphere and on the surface. In this new local time ( 6:45 am/pm) orbit, Odyssey's camera is acquiring expanded diurnal thermal imaging coverage, providing insight into surface texture, layering, and ice content, as well as dynamic, temperature-dependent surface, atmospheric, and polar processes. New THEMIS observations at dawn and dusk local times are filling major gaps in current knowledge about the diurnal variation of clouds, hazes and surface frost. In this presentation, we will highlight some of these data and discuss the unique scientific results that can be obtained from Mars Odyssey THEMIS observations, including: insights into potential past and present habitability of Mars, the processes and history of climate, the nature and evolution of geologic processes, and aspects of the environment relevant to future human exploration.
Task Analysis of Shuttle Entry and Landing Activities
NASA Technical Reports Server (NTRS)
Holland, Albert W.; Vanderark, Stephen T.
1993-01-01
The Task Analysis of Shuttle Entry and Landing (E/L) Activities documents all tasks required to land the Orbiter following an STS mission. In addition to analysis of tasks performed, task conditions are described, including estimated time for completion, altitude, relative velocity, normal and lateral acceleration, location of controls operated or monitored, and level of g's experienced. This analysis precedes further investigations into potential effects of zero g on piloting capabilities for landing the Orbiter following long-duration missions. This includes, but is not limited to, researching the effects of extended duration missions on piloting capabilities. Four primary constraints of the analysis must be clarified: (1) the analysis depicts E/L in a static manner--the actual process is dynamic; (2) the task analysis was limited to a paper analysis, since it was not feasible to conduct research in the actual setting (i.e., observing or filming duration an actual E/L); (3) the tasks included are those required for E/L during nominal, daylight conditions; and (4) certain E/L tasks will vary according to the flying style of each commander.
Development of Shanghai satellite laser ranging station
NASA Technical Reports Server (NTRS)
Yang, Fu-Min; Tan, De-Tong; Xiao, Chi-Kun; Chen, Wan-Zhen; Zhang, J.-H.; Zhang, Z.-P.; Lu, Wen-Hu; Hu, Z.-Q.; Tang, W.-F.; Chen, J.-P.
1993-01-01
The topics covered include the following: improvement of the system hardware; upgrading of the software; the observation status; preliminary daylight tracking capability; testing the new type of laser; and future plans.
Carbon and Energy Saving Financial Opportunities in the Industrial Compressed Air Sector
NASA Astrophysics Data System (ADS)
Vittorini, Diego; Cipollone, Roberto
2017-08-01
The transition towards a more sustainable energy scenario calls for both medium-to-long and short term interventions, with CO2 reduction and fossil fuel saving as main goals for all the Countries in the World. Among all others, one way to support these efforts is the setting-up of immaterial markets able to regulate, in the form of purchase and sales quotas, CO2 emissions avoided and fossil fuels not consumed. As a consequence, the upgrade of those sectors, characterized by high energy impact, is currently more than an option due to the related achievable financial advantage on the afore mentioned markets. Being responsible for about 10% electricity consumption in Industry, the compressed air sector is currently addressed as extremely appealing, when CO2 emissions and burned fossil fuels saving are in question. In the paper, once a standard is defined for compressors performances, based on data from the Compressed Air and Gas Institute and PNEUROP, the achievable energy saving is evaluated along with the effect in terms of CO2 emissions: with reference to those contexts in which mature intangible markets are established, an estimation of the financial benefit from savings sale on correspondent markets is possible, in terms of both avoided CO2 and fossil fuels not burned. The approach adopted allows to extend the analysis results to every context of interest, by applying the appropriate emission factor to the datum on compressor specific consumption.
Cyber Compendium, Professional Continuing Education Course Papers. Volume 2, Issue 1, Spring 2015
2015-01-01
250,000 mobile devices.23 Cutting just 20% of this infrastructure would translate to a potential savings of over $7 Billion per year. Air...BYOD device extends beyond the device itself. There is the supporting infrastructure such as the Mobile Application Store (MAS), which provides access...96 Prioritizing Cyber Capabilities: to Protect U.S. Critical Infrastructure
Saved by the Bell: Derrick Bell's Racial Realism as Pedagogy
ERIC Educational Resources Information Center
Curry, Tommy
2008-01-01
The recent pop culture iconography of the Critical Race Theory (CRT) label has attracted more devoted (white) fans than a 90s boy band. In philosophy, this trend is evidenced by the growing number of white feminists extending their work in gender analogically to questions of race and identity, as well as the unchecked use of the CRT label to…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christian, A T; Coleman, M A; Tucker, J D
2001-02-08
Gene Recovery Microdissection (GRM) is a unique and cost-effective process for producing chromosome region-specific libraries of expressed genes. It accelerates the pace, reduces the cost, and extends the capabilities of functional genomic research, the means by which scientists will put to life-saving, life-enhancing use their knowledge of any plant or animal genome.
Wastewater treatment process impact on energy savings and greenhouse gas emissions.
Mamais, D; Noutsopoulos, C; Dimopoulou, A; Stasinakis, A; Lekkas, T D
2015-01-01
The objective of this research was to assess the energy consumption of wastewater treatment plants (WWTPs), to apply a mathematical model to evaluate their carbon footprint, and to propose energy saving strategies that can be implemented to reduce both energy consumption and greenhouse gas (GHG) emissions in Greece. The survey was focused on 10 WWTPs in Greece with a treatment capacity ranging from 10,000 to 4,000,000 population equivalents (PE). Based on the results, annual specific energy consumption ranged from 15 to 86 kWh/PE. The highest energy consumer in all the WWTPs was aeration, accounting for 40-75% of total energy requirements. The annual GHG emissions varied significantly according to the treatment schemes employed and ranged between 61 and 161 kgCO₂e/PE. The highest values of CO₂emissions were obtained in extended aeration systems and the lowest in conventional activated sludge systems. Key strategies that the wastewater industry could adopt to mitigate GHG emissions are identified and discussed. A case study is presented to demonstrate potential strategies for energy savings and GHG emission reduction. Given the results, it is postulated that the reduction of dissolved oxygen (DO) set points and sludge retention time can provide significant energy savings and decrease GHG emissions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fagan, Mike; Schlachter, Jeremy; Yoshii, Kazutomo
Abstract—Energy and power consumption are major limitations to continued scaling of computing systems. Inexactness where the quality of the solution can be traded for energy savings has been proposed as a counterintuitive approach to overcoming those limitation. However, in the past, inexactness has been necessitated the need for highly customized or specialized hardware. In order to move away from customization, in earlier work [4], it was shown that by interpreting precision in the computation to be the parameter to trade to achieve inexactness, weather prediction and page rank could both benefit in terms of yielding energy savings through reduced precision,more » while preserving the quality of the application. However, this required representations of numbers that were not readily available on commercial off-the-shelf (COTS) processors. In this paper, we provide opportunities for extending the the notion of trading precision for energy savings into the world COTS. We provide a model and analyze the opportunities and behavior of all three IEEE compliant precision values available on COTS processors: (i) double (ii) single, and (iii) half. Through measurements, we show through a limit study energy savings in going from double to half precision can potentially exceed a factor of four, largely due to memory and cache effects.« less
The conservation nexus: valuing interdependent water and energy savings in Arizona.
Bartos, Matthew D; Chester, Mikhail V
2014-02-18
Water and energy resources are intrinsically linked, yet they are managed separately--even in the water-scarce American southwest. This study develops a spatially explicit model of water-energy interdependencies in Arizona and assesses the potential for cobeneficial conservation programs. The interdependent benefits of investments in eight conservation strategies are assessed within the context of legislated renewable energy portfolio and energy efficiency standards. The cobenefits of conservation are found to be significant. Water conservation policies have the potential to reduce statewide electricity demand by 0.82-3.1%, satisfying 4.1-16% of the state's mandated energy-efficiency standard. Adoption of energy-efficiency measures and renewable generation portfolios can reduce nonagricultural water demand by 1.9-15%. These conservation cobenefits are typically not included in conservation plans or benefit-cost analyses. Many cobenefits offer negative costs of saved water and energy, indicating that these measures provide water and energy savings at no net cost. Because ranges of costs and savings for water-energy conservation measures are somewhat uncertain, future studies should investigate the cobenefits of individual conservation strategies in detail. Although this study focuses on Arizona, the analysis can be extended elsewhere as renewable portfolio and energy efficiency standards become more common nationally and internationally.
Maciosek, Michael V; Solberg, Leif I; Coffield, Ashley B; Edwards, Nichol M; Goodman, Michael J
2006-07-01
Influenza causes approximately 36,000 deaths per year in the United States despite the presence of an effective vaccine. This assessment of the value of influenza vaccination to the U.S. population is part of an update to the 2001 ranking of clinical preventive services recommended by the U.S. Preventive Services Task Force. The forthcoming ranking will include the new recommendation of the Advisory Committee on Immunization Practices to extend influenza vaccination to adults aged 50 to 64 years. This service is evaluated on the two most important dimensions: burden of disease prevented and cost effectiveness. Study methods, described in a companion article, are designed to ensure consistency across many services. Over the lifetime of a birth cohort of 4 million, it is estimated that about 275,000 quality-adjusted life years (QALYs) would be saved if influenza vaccination were offered annually to all people after age 50. Eighty percent of the QALYs saved (220,000) would be achieved by offering the vaccine only to persons aged 65 and older. In year 2000 dollars, the cost effectiveness of influenza vaccination is $980 per QALY saved in persons aged 65 and older, and $28,000 per QALY saved in persons aged 50 to 64. When the costs of patient time and travel are excluded, the cost effectiveness ratio of vaccinating 50- to 64-year-olds decreases to $7200 per QALY saved, and vaccinating those aged 65 and older saves $17 per person vaccinated. Influenza vaccination is a high-impact, cost-effective service for persons aged 65 and older. Vaccinations are also cost effective for persons aged 50 to 64.
31 CFR 588.302 - Effective date.
Code of Federal Regulations, 2010 CFR
2010-07-01
... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY WESTERN BALKANS STABILIZATION REGULATIONS General... interests in property are blocked pursuant to § 588.201(a)(1), 12:01 a.m. eastern daylight time, June 27...
14 CFR 103.11 - Daylight operations.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Notwithstanding paragraph (a) of this section, ultralight vehicles may be operated during the twilight periods 30... civil twilight as defined in the Air Almanac, if: (1) The vehicle is equipped with an operating...
... light signal is low, the hypothalamus tells the pineal gland, a small organ situated in the brain, to ... During daylight hours, the opposite occurs, and the pineal gland produces very little melatonin. You may be able ...
NASA Technical Reports Server (NTRS)
Hirschberg, J. G.
1979-01-01
Proposed monitor that detects back-reflected infrared radiation makes in situ turbidity measurements of lakes, streams, and other bodies of water. Monitor is compact, works well in daylight as at night, and is easily operated in rough seas.
Biogeography of time partitioning in mammals.
Bennie, Jonathan J; Duffy, James P; Inger, Richard; Gaston, Kevin J
2014-09-23
Many animals regulate their activity over a 24-h sleep-wake cycle, concentrating their peak periods of activity to coincide with the hours of daylight, darkness, or twilight, or using different periods of light and darkness in more complex ways. These behavioral differences, which are in themselves functional traits, are associated with suites of physiological and morphological adaptations with implications for the ecological roles of species. The biogeography of diel time partitioning is, however, poorly understood. Here, we document basic biogeographic patterns of time partitioning by mammals and ecologically relevant large-scale patterns of natural variation in "illuminated activity time" constrained by temperature, and we determine how well the first of these are predicted by the second. Although the majority of mammals are nocturnal, the distributions of diurnal and crepuscular species richness are strongly associated with the availability of biologically useful daylight and twilight, respectively. Cathemerality is associated with relatively long hours of daylight and twilight in the northern Holarctic region, whereas the proportion of nocturnal species is highest in arid regions and lowest at extreme high altitudes. Although thermal constraints on activity have been identified as key to the distributions of organisms, constraints due to functional adaptation to the light environment are less well studied. Global patterns in diversity are constrained by the availability of the temporal niche; disruption of these constraints by the spread of artificial lighting and anthropogenic climate change, and the potential effects on time partitioning, are likely to be critical influences on species' future distributions.
Robust colour constancy in red-green dichromats
Linhares, João M. M.; Moreira, Humberto; Lillo, Julio; Nascimento, Sérgio M. C.
2017-01-01
Colour discrimination has been widely studied in red-green (R-G) dichromats but the extent to which their colour constancy is affected remains unclear. This work estimated the extent of colour constancy for four normal trichromatic observers and seven R-G dichromats when viewing natural scenes under simulated daylight illuminants. Hyperspectral imaging data from natural scenes were used to generate the stimuli on a calibrated CRT display. In experiment 1, observers viewed a reference scene illuminated by daylight with a correlated colour temperature (CCT) of 6700K; observers then viewed sequentially two versions of the same scene, one illuminated by either a higher or lower CCT (condition 1, pure CCT change with constant luminance) or a higher or lower average luminance (condition 2, pure luminance change with a constant CCT). The observers’ task was to identify the version of the scene that looked different from the reference scene. Thresholds for detecting a pure CCT change or a pure luminance change were estimated, and it was found that those for R-G dichromats were marginally higher than for normal trichromats regarding CCT. In experiment 2, observers viewed sequentially a reference scene and a comparison scene with a CCT change or a luminance change above threshold for each observer. The observers’ task was to identify whether or not the change was an intensity change. No significant differences were found between the responses of normal trichromats and dichromats. These data suggest robust colour constancy mechanisms along daylight locus in R-G dichromacy. PMID:28662218
Robust colour constancy in red-green dichromats.
Álvaro, Leticia; Linhares, João M M; Moreira, Humberto; Lillo, Julio; Nascimento, Sérgio M C
2017-01-01
Colour discrimination has been widely studied in red-green (R-G) dichromats but the extent to which their colour constancy is affected remains unclear. This work estimated the extent of colour constancy for four normal trichromatic observers and seven R-G dichromats when viewing natural scenes under simulated daylight illuminants. Hyperspectral imaging data from natural scenes were used to generate the stimuli on a calibrated CRT display. In experiment 1, observers viewed a reference scene illuminated by daylight with a correlated colour temperature (CCT) of 6700K; observers then viewed sequentially two versions of the same scene, one illuminated by either a higher or lower CCT (condition 1, pure CCT change with constant luminance) or a higher or lower average luminance (condition 2, pure luminance change with a constant CCT). The observers' task was to identify the version of the scene that looked different from the reference scene. Thresholds for detecting a pure CCT change or a pure luminance change were estimated, and it was found that those for R-G dichromats were marginally higher than for normal trichromats regarding CCT. In experiment 2, observers viewed sequentially a reference scene and a comparison scene with a CCT change or a luminance change above threshold for each observer. The observers' task was to identify whether or not the change was an intensity change. No significant differences were found between the responses of normal trichromats and dichromats. These data suggest robust colour constancy mechanisms along daylight locus in R-G dichromacy.
Gellerfors, Mikael; Svensén, Christer; Linde, Joacim; Lossius, Hans Morten; Gryth, Dan
2015-09-01
Securing the airway by endotracheal intubation (ETI) is a key issue in prehospital critical care. Night vision goggles (NVG) are used by personnel operating in low-light environments. We examined the feasibility of an anesthesiologist performed ETI using NVG in a helicopter setting. Twelve anesthesiologists performed ETI on a manikin in an emergency room (ER) setting and two helicopter settings, with randomization to either rotary wing daylight (RW-D) or rotary wing in total darkness using binocular NVG (RW-NVG). Primary endpoint was intubation time. Secondary endpoints included success rate, Cormack-Lehane (CL) score, and subjective difficulty according to the Visual Analoge Scale (VAS). The median intubation time was shorter for the RW-D compared to the RW-NVG setting (16.5 seconds vs. 30.0 seconds; p = 0,03). We found no difference in median intubation time for the ER and RW-D settings (16.8 seconds vs. 16.5 seconds; p = 0.91). For all scenarios, success rate was 100%. CL and VAS varied between the ER setting (CL 1.8, VAS 2.8), RW-D setting (CL 2.0, VAS 3.0), and RW-NVG setting (CL 3.0, VAS 6.5). This study suggests that anesthesiologists successfully and quickly can perform ETI in a helicopter setting both in daylight and in darkness using binocular NVG, but with shorter intubation times in daylight. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.
U.S. pharmacy policy: a public health perspective on safety and cost.
Rosenau, Pauline Vaillancourt; Lal, Lincy S; Glasser, Jay H
2009-01-01
A public health perspective based on social justice and a population health point of view emphasizes pharmacy policy innovations regarding safety and costs. Such policies that effectively reduce costs include controlling profits, establishing profit targets, extending prescription providers, revising prescription classification schemes, emphasizing generic medications, and establishing formularies. Public education and universal programs may reduce costs, but co-pays and "cost-sharing" do not. Switching medications to over-the-counter (OTC) status, pill splitting, and importing medication from abroad are poor substitutes for authentic public health pharmacy policy. Where policy changes yield savings, public health insists that these savings should be used to increase access and improve population health. In the future, pharmacy policies may emphasize public health accountability more than individual liberty because of potential cost savings to society. Fear of litigation, as an informal mechanism of focusing manufacturer's attention on safety, is inefficient; public health pharmacy policy regarding safety looks toward a more active regulatory role on the part of government. A case study of direct-to-consumer advertising illustrates the complexity of public health pharmacy policy.
Energy savings opportunities in the global digital television transition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Won Young; Gopal, Anand; Phadke, Amol
Globally, terrestrial television (TV) broadcasting is in the midst of a complete transition to digital signals. The last analog terrestrial broadcast is expected to be switched off in the early 2020s. This transition presents huge energy savings opportunities that have thus far been ignored. Digital TV switchovers have likely increased energy consumption as countries have completed transitions by providing digital TV converters to analog TV users, which increase energy consumption and extend the life of energy-inefficient analog TVs. We find that if analog TVs were retired at the time of a digital switchover and replaced with super-efficient flat-panel TVs, suchmore » as light-emitting diode (LED) backlit liquid crystal display (LCD) TVs, there is a combined electricity savings potential of 32 terawatt hours [TWh] per year in countries that have not yet completed their digital TV transition. In view of these findings as well as the dramatic drops of super-efficient TV prices and the unique early-retirement opportunity resulting from cessation of terrestrial analog broadcasts, TV-exchange programs would easily and substantially advance energy efficiency.« less
Energy savings opportunities in the global digital television transition
Park, Won Young; Gopal, Anand; Phadke, Amol
2016-12-20
Globally, terrestrial television (TV) broadcasting is in the midst of a complete transition to digital signals. The last analog terrestrial broadcast is expected to be switched off in the early 2020s. This transition presents huge energy savings opportunities that have thus far been ignored. Digital TV switchovers have likely increased energy consumption as countries have completed transitions by providing digital TV converters to analog TV users, which increase energy consumption and extend the life of energy-inefficient analog TVs. We find that if analog TVs were retired at the time of a digital switchover and replaced with super-efficient flat-panel TVs, suchmore » as light-emitting diode (LED) backlit liquid crystal display (LCD) TVs, there is a combined electricity savings potential of 32 terawatt hours [TWh] per year in countries that have not yet completed their digital TV transition. In view of these findings as well as the dramatic drops of super-efficient TV prices and the unique early-retirement opportunity resulting from cessation of terrestrial analog broadcasts, TV-exchange programs would easily and substantially advance energy efficiency.« less