Sample records for extensive testing including

  1. Criterion-Related Validity of Sit-and-Reach Tests for Estimating Hamstring and Lumbar Extensibility: a Meta-Analysis

    PubMed Central

    Mayorga-Vega, Daniel; Merino-Marban, Rafael; Viciana, Jesús

    2014-01-01

    The main purpose of the present meta-analysis was to examine the scientific literature on the criterion-related validity of sit-and-reach tests for estimating hamstring and lumbar extensibility. For this purpose relevant studies were searched from seven electronic databases dated up through December 2012. Primary outcomes of criterion-related validity were Pearson´s zero-order correlation coefficients (r) between sit-and-reach tests and hamstrings and/or lumbar extensibility criterion measures. Then, from the included studies, the Hunter- Schmidt´s psychometric meta-analysis approach was conducted to estimate population criterion- related validity of sit-and-reach tests. Firstly, the corrected correlation mean (rp), unaffected by statistical artefacts (i.e., sampling error and measurement error), was calculated separately for each sit-and-reach test. Subsequently, the three potential moderator variables (sex of participants, age of participants, and level of hamstring extensibility) were examined by a partially hierarchical analysis. Of the 34 studies included in the present meta-analysis, 99 correlations values across eight sit-and-reach tests and 51 across seven sit-and-reach tests were retrieved for hamstring and lumbar extensibility, respectively. The overall results showed that all sit-and-reach tests had a moderate mean criterion-related validity for estimating hamstring extensibility (rp = 0.46-0.67), but they had a low mean for estimating lumbar extensibility (rp = 0. 16-0.35). Generally, females, adults and participants with high levels of hamstring extensibility tended to have greater mean values of criterion-related validity for estimating hamstring extensibility. When the use of angular tests is limited such as in a school setting or in large scale studies, scientists and practitioners could use the sit-and-reach tests as a useful alternative for hamstring extensibility estimation, but not for estimating lumbar extensibility. Key Points Overall sit-and-reach tests have a moderate mean criterion-related validity for estimating hamstring extensibility, but they have a low mean validity for estimating lumbar extensibility. Among all the sit-and-reach test protocols, the Classic sit-and-reach test seems to be the best option to estimate hamstring extensibility. End scores (e.g., the Classic sit-and-reach test) are a better indicator of hamstring extensibility than the modifications that incorporate fingers-to-box distance (e.g., the Modified sit-and-reach test). When angular tests such as straight leg raise or knee extension tests cannot be used, sit-and-reach tests seem to be a useful field test alternative to estimate hamstring extensibility, but not to estimate lumbar extensibility. PMID:24570599

  2. Utility of an interferon-gamma release assay for latent tuberculosis diagnosis in a case of bullous pemphigoid.

    PubMed

    Goodfellow, Alfred; Keeling, Douglas N; Hayes, Robert C; Webster, Duncan

    2009-01-01

    With increasing use of immunosuppressive therapy, including tumor necrosis factor alpha inhibitors, there is concern about infectious complications, including reactivation of latent Mycobacterium tuberculosis infection. Routine testing prior to administration of systemic immunosuppression includes the tuberculin skin test, which lacks sensitivity and specificity and may be difficult to interpret in the presence of extensive cutaneous disease. Treatment of individuals with latent tuberculosis infection is recommended when immunosuppressive medications are to be employed. We report a case in which a diagnosis of latent tuberculosis infection in a patient with extensive bullous pemphigoid was clarified by the use of an interferon-gamma release assay after equivocal tuberculin skin test results. Interferon-gamma release assays are useful adjuncts to the tuberculin skin test in the diagnosis of latent tuberculosis infection in the setting of extensive cutaneous disease.

  3. Power Extension Package (PEP) system definition extension, orbital service module systems analysis study. Volume 9: PEP design, development and test plans

    NASA Technical Reports Server (NTRS)

    1979-01-01

    A plan for the production of two PEP flight systems is defined. The task's milestones are described. Provisions for the development and assembly of new ground support equipment required for both testing and launch operations are included.

  4. Design of a composite wing extension for a general aviation aircraft

    NASA Technical Reports Server (NTRS)

    Adney, P. S.; Horn, W. J.

    1984-01-01

    A composite wing extension was designed for a typical general aviation aircraft to improve lift curve slope, dihedral effect, and lift to drag ratio. Advanced composite materials were used in the design to evaluate their use as primary structural components in general aviation aircraft. Extensive wind tunnel tests were used to evaluate six extension shapes. The extension shape chosen as the best choice was 28 inches long with a total area of 17 square feet. Subsequent flight tests showed the wing extension's predicted aerodynamic improvements to be correct. The structural design of the wing extension consisted of a hybrid laminate carbon core with outer layers of Kevlar - layed up over a foam interior which acted as an internal support. The laminate skin of the wing extension was designed from strength requirements, and the foam core was included to prevent buckling. A joint lap was recommended to attach the wing extension to the main wing structure.

  5. Upper Stage Engine Composite Nozzle Extensions

    NASA Technical Reports Server (NTRS)

    Valentine, Peter G.; Allen, Lee R.; Gradl, Paul R.; Greene, Sandra E.; Sullivan, Brian J.; Weller, Leslie J.; Koenig, John R.; Cuneo, Jacques C.; Thompson, James; Brown, Aaron; hide

    2015-01-01

    Carbon-carbon (C-C) composite nozzle extensions are of interest for use on a variety of launch vehicle upper stage engines and in-space propulsion systems. The C-C nozzle extension technology and test capabilities being developed are intended to support National Aeronautics and Space Administration (NASA) and United States Air Force (USAF) requirements, as well as broader industry needs. Recent and on-going efforts at the Marshall Space Flight Center (MSFC) are aimed at both (a) further developing the technology and databases for nozzle extensions fabricated from specific CC materials, and (b) developing and demonstrating low-cost capabilities for testing composite nozzle extensions. At present, materials development work is concentrating on developing a database for lyocell-based C-C that can be used for upper stage engine nozzle extension design, modeling, and analysis efforts. Lyocell-based C-C behaves in a manner similar to rayon-based CC, but does not have the environmental issues associated with the use of rayon. Future work will also further investigate technology and database gaps and needs for more-established polyacrylonitrile- (PAN-) based C-C's. As a low-cost means of being able to rapidly test and screen nozzle extension materials and structures, MSFC has recently established and demonstrated a test rig at MSFC's Test Stand (TS) 115 for testing subscale nozzle extensions with 3.5-inch inside diameters at the attachment plane. Test durations of up to 120 seconds have been demonstrated using oxygen/hydrogen propellants. Other propellant combinations, including the use of hydrocarbon fuels, can be used if desired. Another test capability being developed will allow the testing of larger nozzle extensions (13.5- inch inside diameters at the attachment plane) in environments more similar to those of actual oxygen/hydrogen upper stage engines. Two C-C nozzle extensions (one lyocell-based, one PAN-based) have been fabricated for testing with the larger-scale facility.

  6. Development and Testing of Carbon-Carbon Nozzle Extensions for Upper Stage Liquid Rocket Engines

    NASA Technical Reports Server (NTRS)

    Valentine, Peter G.; Gradl, Paul R.; Greene, Sandra E.

    2017-01-01

    Carbon-carbon (C-C) composite nozzle extensions are of interest for use on a variety of launch vehicle upper stage engines and in-space propulsion systems. The C-C nozzle extension technology and test capabilities being developed are intended to support National Aeronautics and Space Administration (NASA) and Department of Defense (DOD) requirements, as well as those of the broader Commercial Space industry. For NASA, C-C nozzle extension technology development primarily supports the NASA Space Launch System (SLS) and NASA's Commercial Space partners. Marshall Space Flight Center (MSFC) efforts are aimed at both (a) further developing the technology and databases needed to enable the use of composite nozzle extensions on cryogenic upper stage engines, and (b) developing and demonstrating low-cost capabilities for testing and qualifying composite nozzle extensions. Recent, on-going, and potential future work supporting NASA, DOD, and Commercial Space needs will be discussed. Information to be presented will include (a) recent and on-going mechanical, thermal, and hot-fire testing, as well as (b) potential future efforts to further develop and qualify domestic C-C nozzle extension solutions for the various upper stage engines under development.

  7. The NASA modern technology rotors program

    NASA Technical Reports Server (NTRS)

    Watts, M. E.; Cross, J. L.

    1986-01-01

    Existing data bases regarding helicopters are based on work conducted on 'old-technology' rotor systems. The Modern Technology Rotors (MTR) Program is to provide extensive data bases on rotor systems using present and emerging technology. The MTR is concerned with modern, four-bladed, rotor systems presently being manufactured or under development. Aspects of MTR philosophy are considered along with instrumentation, the MTR test program, the BV 360 Rotor, and the UH-60 Black Hawk. The program phases include computer modelling, shake test, model-scale test, minimally instrumented flight test, extensively pressure-instrumented-blade flight test, and full-scale wind tunnel test.

  8. Interpretation and Utilization of Scores on the Air Force Officer Qualifying Test.

    ERIC Educational Resources Information Center

    Miller, Robert E.

    The report summarizes a large body of data relevant to the proper interpretation and use of aptitude scores on the Air Force Officer Qualifying Test (AFOQT). Included are descriptions of the AFOQT testing program and the test itself. Technical data include an extensive sampling of validation studies covering predictors of success in pilot…

  9. 77 FR 46750 - Agency Information Collection Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-06

    ... Questionnaire Testing, Evaluation, and Research.'' The proposed collection will utilize qualitative and quantitative methodologies to pretest questionnaires and validate EIA survey forms data quality, including..., Evaluation, and Research; (3) Type of Request: Extension, Without Change, of a Previously Approved Collection...

  10. An Extension and Test of Sutherland's Concept of Differential Social Organization: The Geographic Clustering of Japanese Suicide and Homicide Rates

    ERIC Educational Resources Information Center

    Baller, Robert D.; Shin, Dong-Joon; Richardson, Kelly K.

    2005-01-01

    In an effort to explain the spatial patterning of violence, we expanded Sutherland's (1947) concept of differential social organization to include the level of deviance exhibited by neighboring areas. To test the value of this extension, the geographic clustering of Japanese suicide and homicide rates is assessed using 1985 and 1995 data for…

  11. Clinical Effects of Dry Needling Among Asymptomatic Individuals With Hamstring Tightness: A Randomized Controlled Trial.

    PubMed

    Geist, Kathleen; Bradley, Claire; Hofman, Alan; Koester, Rob; Roche, Fenella; Shields, Annalise; Frierson, Elizabeth; Rossi, Ainsley; Johanson, Marie

    2017-11-01

    Randomized controlled trial. The aim of this study was to determine the effects of dry needling on hamstring extensibility and functional performance tests among asymptomatic individuals with hamstring muscle tightness. Dry needling has been shown to increase range of motion in the upper quarter and may have similar effects in the lower quarter. 27 subjects with hamstring extensibility deficits were randomly assigned to side of treatment (dominant or nondominant) and group (blunt needling or dry needling). The first session included measurement of hamstring extensibility and performance on 4 unilateral hop tests, instruction in home hamstring stretching exercises and needling distal to the ischial tuberosity and midbellies of the medial and lateral hamstrings. A second session, 3-5 days following the first session, included outcome measures and a second needling intervention, and a third session, 4-6 weeks following the first session, included outcome measures only. A 2 × 3 × 2 ANOVA was used to statistically analyze the data. Hamstring extensibility showed a significant side × time interaction (P < .05). The single hop for distance, timed 6-meter hop, and the crossover hop test had a significant main effect of time (P < .05). The triple hop for distance showed a significant side × time × group interaction (P < .05). It does not appear dry needling results in increased extensibility beyond that of stretching alone in asymptomatic individuals. Our study findings suggest that dry needling may improve certain dimensions of functional performance, although no clear conclusion can be made. Intervention, level 2b.

  12. Use of coal fly ash and other waste products in soil stabilization and road construction including non-destructive testing of roadways.

    DOT National Transportation Integrated Search

    2012-06-01

    An extensive laboratory testing program was performed on subgrade soils stabilized using fly ash and : lime kiln dust. The laboratory program included measurements of: compaction curves, small strain elastic moduli, : resilient modulus (Mr), Briaud C...

  13. Use of coal fly ash and other waste products in soil stabilization and road construction-including non-destructive testing of roadways.

    DOT National Transportation Integrated Search

    2012-02-01

    An extensive laboratory testing program was performed on subgrade soils stabilized using fly ash and lime kiln dust. The laboratory : program included measurements of: compaction curves, small strain elastic moduli, resilient modulus (Mr), Briaud Com...

  14. Investigation in Simulated Vertical Descent of the Characteristics of a Cargo-Dropping Device having Extensible Rotating Blades

    NASA Technical Reports Server (NTRS)

    Stone, Ralph W., Jr.; Hultz, Burton E.

    1949-01-01

    The characteristics of a cargo-dropping device having extensible rotating blades as load-carrying surfaces have been studied in simulated vertical descent in the Langley 20-foot free-spinning tunnel. The investigation included tests to determine the variation in vertical sinking speed with load. A study of the blade characteristics and of the test results indicated a method of dynamically balancing the blades to permit proper functioning of the device.

  15. Enhancing graphical literacy skills in the high school science classroom via authentic, intensive data collection and graphical representation exposure

    NASA Astrophysics Data System (ADS)

    Palmeri, Anthony

    This research project was developed to provide extensive practice and exposure to data collection and data representation in a high school science classroom. The student population engaged in this study included 40 high school sophomores enrolled in two microbiology classes. Laboratory investigations and activities were deliberately designed to include quantitative data collection that necessitated organization and graphical representation. These activities were embedded into the curriculum and conducted in conjunction with the normal and expected course content, rather than as a separate entity. It was expected that routine practice with graph construction and interpretation would result in improved competency when graphing data and proficiency in analyzing graphs. To objectively test the effectiveness in achieving this goal, a pre-test and post-test that included graph construction, interpretation, interpolation, extrapolation, and analysis was administered. Based on the results of a paired T-Test, graphical literacy was significantly enhanced by extensive practice and exposure to data representation.

  16. American grandparents providing extensive child care to their grandchildren: prevalence and profile.

    PubMed

    Fuller-Thomson, E; Minkler, M

    2001-04-01

    This study sought to determine the prevalence and profile of grandparents providing extensive care for a grandchild (grandparents who provide 30+ hours per week or 90+ nights per year of child care, yet are not the primary caregiver of the grandchild). Secondary analysis of the 3,260 grandparent respondents in the 1992-94 National Survey of Families and Households (NSFH). Extensively caregiving grandparents were compared with custodial grandparents (those with primary responsibility for raising a grandchild for 6+ months), noncaregivers, occasional caregivers (<10 hours per week), and intermediate caregivers using chi-square tests, one-way analysis of variance tests, and logistic regression analyses. Close to 7% of all grandparents provided extensive caregiving, as did 14.9% of those who had provided any grandchild care in the last month. Extensive caregivers most closely resembled custodial caregivers and had least in common with those grandparents who never provided child care. Areas for future research, policy, and practice are highlighted, including the potential impact of welfare reform legislation on extensively caregiving grandparents.

  17. Association of lower extremity range of motion and muscle strength with physical performance of community-dwelling older women.

    PubMed

    Jung, Hungu; Yamasaki, Masahiro

    2016-12-08

    Reduced lower extremity range of motion (ROM) and muscle strength are related to functional disability in older adults who cannot perform one or more activities of daily living (ADL) independently. The purpose of this study was to determine which factors of seven lower extremity ROMs and two muscle strengths play dominant roles in the physical performance of community-dwelling older women. Ninety-five community-dwelling older women (mean age ± SD, 70.7 ± 4.7 years; age range, 65-83 years) were enrolled in this study. Seven lower extremity ROMs (hip flexion, hip extension, knee flexion, internal and external hip rotation, ankle dorsiflexion, and ankle plantar flexion) and two muscle strengths (knee extension and flexion) were measured. Physical performance tests, including functional reach test (FRT), 5 m gait test, four square step test (FSST), timed up and go test (TUGT), and five times sit-to-stand test (FTSST) were performed. Stepwise regression models for each of the physical performance tests revealed that hip extension ROM and knee flexion strength were important explanatory variables for FRT, FSST, and FTSST. Furthermore, ankle plantar flexion ROM and knee extension strength were significant explanatory variables for the 5 m gait test and TUGT. However, ankle dorsiflexion ROM was a significant explanatory variable for FRT alone. The amount of variance on stepwise multiple regression for the five physical performance tests ranged from 25 (FSST) to 47% (TUGT). Hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs, as well as knee extension and flexion strengths may play primary roles in the physical performance of community-dwelling older women. Further studies should assess whether specific intervention programs targeting older women may achieve improvements in lower extremity ROM and muscle strength, and thereby play an important role in the prevention of dependence on daily activities and loss of physical function, particularly focusing on hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs as well as knee extension and flexion strength.

  18. The NASA supercritical-wing technology

    NASA Technical Reports Server (NTRS)

    Bartlett, D. W.; Patterson, J. C., Jr.

    1978-01-01

    A number of high aspect ratio supercritical wings in combination with a representative wide body type fuselage were tested in the Langley 8 foot transonic pressure tunnel. The wing parameters investigated include aspect ratio, sweep, thickness to chord ratio, and camber. Subsequent to these initial series of tests, a particular wing configuration was selected for further study and development. Tests on the selected wing involved the incorporation of a larger inboard trailing edge extension, an inboard leading edge extension, and flow through nacelles. Range factors for the various supercritical wing configurations are compared with those for a reference wide body transport configuration.

  19. Composite Overwrapped Pressure Vessels: Database Extension Task 3.0 and Impact Damage Effects Control Task 8.0

    NASA Technical Reports Server (NTRS)

    Beeson, Harold D.; Davis, Dennis D.; Ross, William L., Sr.; Tapphorn, Ralph M.

    2002-01-01

    This document represents efforts accomplished at the NASA Johnson Space Center White Sands Test Facility (WSTF) in support of the Enhanced Technology for Composite Overwrapped Pressure Vessels (COPV) Program, a joint research and technology effort among the U.S. Air Force, NASA, and the Aerospace Corporation. WSTF performed testing for several facets of the program. Testing that contributed to the Task 3.0 COPV database extension objective included baseline structural strength, failure mode and safe-life, impact damage tolerance, sustained load/impact effect, and materials compatibility. WSTF was also responsible for establishing impact protection and control requirements under Task 8.0 of the program. This included developing a methodology for establishing an impact control plan. Seven test reports detail the work done at WSTF. As such, this document contributes to the database of information regarding COPV behavior that will ensure performance benefits and safety are maintained throughout vessel service life.

  20. Apollo experience report environmental acceptance testing

    NASA Technical Reports Server (NTRS)

    Laubach, C. H. M.

    1976-01-01

    Environmental acceptance testing was used extensively to screen selected spacecraft hardware for workmanship defects and manufacturing flaws. The minimum acceptance levels and durations and methods for their establishment are described. Component selection and test monitoring, as well as test implementation requirements, are included. Apollo spacecraft environmental acceptance test results are summarized, and recommendations for future programs are presented.

  1. Psychometric Analysis of the Diagnostic Evaluation of Language Variation-Screening Test: Extension to Low-Income African American Pre-Kindergarteners

    ERIC Educational Resources Information Center

    Terry, Nicole P.; Petscher, Yaacov; Rhodes, Katherine T.

    2017-01-01

    The purpose of this study was to extend a previous investigation of the psychometrics of the "Diagnostic Evaluation of Language Variation-Screening Test" (DELV-S) to include pre-kindergarten children (primarily African American and from low-income households). The previous study (Petscher, Connor, & Al Otaiba, 2012) included a…

  2. Carbon-Carbon Nozzle Extension Development in Support of In-Space and Upper-Stage Liquid Rocket Engines

    NASA Technical Reports Server (NTRS)

    Gradl, Paul R.; Valentine, Peter G.

    2017-01-01

    Upper stage and in-space liquid rocket engines are optimized for performance through the use of high area ratio nozzles to fully expand combustion gases to low exit pressures, increasing exhaust velocities. Due to the large size of such nozzles, and the related engine performance requirements, carbon-carbon (C-C) composite nozzle extensions are being considered to reduce weight impacts. Currently, the state-of-the-art is represented by the metallic and foreign composite nozzle extensions limited to approximately 2000 degrees F. used on the Atlas V, Delta IV, Falcon 9, and Ariane 5 launch vehicles. NASA and industry partners are working towards advancing the domestic supply chain for C-C composite nozzle extensions. These development efforts are primarily being conducted through the NASA Small Business Innovation Research (SBIR) program in addition to other low level internal research efforts. This has allowed for the initial material development and characterization, subscale hardware fabrication, and completion of hot-fire testing in relevant environments. NASA and industry partners have designed, fabricated and hot-fire tested several subscale domestically produced C-C extensions to advance the material and coatings fabrication technology for use with a variety of liquid rocket and scramjet engines. Testing at NASA's Marshall Space Flight Center (MSFC) evaluated heritage and state-of-the-art C-C materials and coatings, demonstrating the initial capabilities of the high temperature materials and their fabrication methods. This paper discusses the initial material development, design and fabrication of the subscale carbon-carbon nozzle extensions, provides an overview of the test campaign, presents results of the hot fire testing, and discusses potential follow-on development work. The follow on work includes the fabrication of ultra-high temperature materials, larger C-C nozzle extensions, material characterization, sub-element testing and hot-fire testing at larger scale.

  3. Automatic Vacuum Flushing Technology for Combined Sewer Solids: Laboratory Testing and Proposed Improvements (WERF Report INFR7SG09)

    EPA Science Inventory

    This research study included an extensive literature review on existing sewer sediment flushing technologies. An innovative vacuum flush system previously developed by the U.S. EPA was tested under laboratory conditions. The tests revealed a strong correlation between the strengt...

  4. Transparent superstrate terrestrial solar cell module

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The design, development, fabrication, and testing of the transparent solar cell module were examined. Cell performance and material process characteristics were determined by extensive tests and design modifications were made prior to preproduction fabrication. These tests included three cell submodules and two full size engineering modules. Along with hardware and test activity, engineering documentation was prepared and submitted.

  5. Forced knee extension test is a manual test that correlates with the unstable feelings of patients with ACL injury before and after reconstruction.

    PubMed

    Shirasawa, Shinichi; Koga, Hideyuki; Horie, Masafumi; Nakamura, Tomomasa; Watanabe, Toshifumi; Sekiya, Ichiro; Muneta, Takeshi

    2016-12-01

    To investigate fear in patients with anterior cruciate ligament (ACL) injury before and after reconstruction, a forced knee extension (FKE) test was performed. The correlation of the test results was evaluated with the subjective function, sports performance and objective parameters. The study included 102 patients with unilateral ACL reconstruction using a semitendinosus tendon with full clinical evaluation. This study was retrospective and determined the longitudinal results of the FKE test and investigated the effects on the subjective and objective outcomes at 2years. Preoperatively, 47% of patients showed positive FKE tests. The number of positive FKE tests was 31% at six months and 15% at 24months after ACL reconstruction. At two years, there were statistically significant differences between the FKE test positives and negatives regarding both subjective knee recovery (P=0.0095) and sports performance (P=0.0006). A new manual test, called the forced knee extension test, for fear in patients with ACL injury before and after reconstruction was introduced. The apprehension remained positive in 15% of the patients two years after ACL reconstruction, which affected subjective recovery of knee function and sports performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Technology advancement of the static feed water electrolysis process

    NASA Technical Reports Server (NTRS)

    Schubert, F. H.; Wynveen, R. A.

    1977-01-01

    A program to advance the technology of oxygen- and hydrogen-generating subsystems based on water electrolysis was studied. Major emphasis was placed on static feed water electrolysis, a concept characterized by low power consumption and high intrinsic reliability. The static feed based oxygen generation subsystem consists basically of three subassemblies: (1) a combined water electrolysis and product gas dehumidifier module; (2) a product gas pressure controller and; (3) a cyclically filled water feed tank. Development activities were completed at the subsystem as well as at the component level. An extensive test program including single cell, subsystem and integrated system testing was completed with the required test support accessories designed, fabricated, and assembled. Mini-product assurance activities were included throughout all phases of program activities. An extensive number of supporting technology studies were conducted to advance the technology base of the static feed water electrolysis process and to resolve problems.

  7. NASA Data Acquisition System Software Development for Rocket Propulsion Test Facilities

    NASA Technical Reports Server (NTRS)

    Herbert, Phillip W., Sr.; Elliot, Alex C.; Graves, Andrew R.

    2015-01-01

    Current NASA propulsion test facilities include Stennis Space Center in Mississippi, Marshall Space Flight Center in Alabama, Plum Brook Station in Ohio, and White Sands Test Facility in New Mexico. Within and across these centers, a diverse set of data acquisition systems exist with different hardware and software platforms. The NASA Data Acquisition System (NDAS) is a software suite designed to operate and control many critical aspects of rocket engine testing. The software suite combines real-time data visualization, data recording to a variety formats, short-term and long-term acquisition system calibration capabilities, test stand configuration control, and a variety of data post-processing capabilities. Additionally, data stream conversion functions exist to translate test facility data streams to and from downstream systems, including engine customer systems. The primary design goals for NDAS are flexibility, extensibility, and modularity. Providing a common user interface for a variety of hardware platforms helps drive consistency and error reduction during testing. In addition, with an understanding that test facilities have different requirements and setups, the software is designed to be modular. One engine program may require real-time displays and data recording; others may require more complex data stream conversion, measurement filtering, or test stand configuration management. The NDAS suite allows test facilities to choose which components to use based on their specific needs. The NDAS code is primarily written in LabVIEW, a graphical, data-flow driven language. Although LabVIEW is a general-purpose programming language; large-scale software development in the language is relatively rare compared to more commonly used languages. The NDAS software suite also makes extensive use of a new, advanced development framework called the Actor Framework. The Actor Framework provides a level of code reuse and extensibility that has previously been difficult to achieve using LabVIEW. The

  8. The DOE ETV-1 Electric Test Vehicle. Phase 3: Performance Testing and system evaluation

    NASA Technical Reports Server (NTRS)

    Kurtz, D.

    1981-01-01

    Engineering tests were conducted in order to characterize overall system performance and component efficiencies within the system environment. A dynamometer was used in order to minimize the ambient effects and large uncertainties present in track testing. Extensive test requirements were defined and procedures were carefully controlled in order to maintain a high degree of credibility. Limited track testing was performed in order to corroborate the dynamometer results. Test results include an energy flow analysis through the major subsystems and incorporate the aerodynamic and rolling losses under cyclic and various steady speed conditions. The major output from all relevant dynamometer and track tests is also included.

  9. Space Suit Portable Life Support System (PLSS) 2.0 Unmanned Vacuum Environment Testing

    NASA Technical Reports Server (NTRS)

    Watts, Carly; Vogel, Matthew

    2016-01-01

    For the first time in more than 30 years, an advanced space suit Portable Life Support System (PLSS) design was operated inside a vacuum chamber representative of the flight operating environment. The test article, PLSS 2.0, was the second system-level integrated prototype of the advanced PLSS design, following the PLSS 1.0 Breadboard that was developed and tested throughout 2011. Whereas PLSS 1.0 included five technology development components with the balance the system simulated using commercial-off-the-shelf items, PLSS 2.0 featured first generation or later prototypes for all components less instrumentation, tubing and fittings. Developed throughout 2012, PLSS 2.0 was the first attempt to package the system into a flight-like representative volume. PLSS 2.0 testing included an extensive functional evaluation known as Pre-Installation Acceptance (PIA) testing, Human-in-the-Loop testing in which the PLSS 2.0 prototype was integrated via umbilicals to a manned prototype space suit for 19 two-hour simulated EVAs, and unmanned vacuum environment testing. Unmanned vacuum environment testing took place from 1/9/15-7/9/15 with PLSS 2.0 located inside a vacuum chamber. Test sequences included performance mapping of several components, carbon dioxide removal evaluations at simulated intravehicular activity (IVA) conditions, a regulator pressure schedule assessment, and culminated with 25 simulated extravehicular activities (EVAs). During the unmanned vacuum environment test series, PLSS 2.0 accumulated 378 hours of integrated testing including 291 hours of operation in a vacuum environment and 199 hours of simulated EVA time. The PLSS prototype performed nominally throughout the test series, with two notable exceptions including a pump failure and a Spacesuit Water Membrane Evaporator (SWME) leak, for which post-test failure investigations were performed. In addition to generating an extensive database of PLSS 2.0 performance data, achievements included requirements and operational concepts verification, as well as demonstration of vehicular interfaces, consumables sizing and recharge, and water quality control.

  10. Validation of contractor HMA testing data in the materials acceptance process - phase II : final report.

    DOT National Transportation Integrated Search

    2016-08-01

    This study conducted an analysis of the SCDOT HMA specification. A Research Steering Committee provided oversight : of the process. The research process included extensive statistical analyses of test data supplied by SCDOT. : A total of 2,789 AC tes...

  11. Elbow arthroscopy: valgus extension overload.

    PubMed

    Ahmad, Christopher S; Conway, John E

    2011-01-01

    Valgus torque combined with deceleration produces high compression and shear forces acting on the posteromedial olecranon and the posteromedial trochlea. This valgus extension overload process may cause posteromedial trochlea chondromalacia, chondral flap formation, osteochondrosis, subchondral erosion, a subchondral insufficiency fracture, and marginal exostosis formation. Olecranon pathologies include proximal stress reaction, a posteromedial tip stress fracture, a transverse proximal process stress fracture, exostosis formation, exostosis fragmentation, and intra-articular loose bodies. Symptoms include posteromedial elbow pain during the deceleration phase of the throwing motion. The extension impingement test reproduces posterior or posteromedial pain similar to that experienced while throwing. Special radiographic techniques and CT scans can show loose bodies and osteophyte fragmentation. Surgical treatment is indicated when symptoms persist despite nonsurgical management. Based on clinical and basic science research, all patients with valgus extension overload should be comprehensively evaluated for medial ulnar collateral ligament insufficiency. Surgical treatment is limited to the resection of osteophytes only; normal olecranon should not be resected.

  12. EMPTAC (Electromagnetic Pulse Test Aircraft) user's guide

    NASA Astrophysics Data System (ADS)

    Cleaveland, Dale R.; Burkhard, Avery

    1988-04-01

    This guide was established to give test managers a way to familiarize themselves with the Air Force Weapons Laboratory's electromagnetic pulse (EMP) test aircraft program located at Kirtland Air Force Base (KAFB), New Mexico. Brief descriptions of the available EMP test facilities at KAFB are also included. This guide should give prospective customers (users) adequate information to scope the magnitude of their test effort and to accomplish general planning without extensive involvement in test execution details.

  13. Experimental tests of relativistic gravitation theories

    NASA Technical Reports Server (NTRS)

    Anderson, J. D.

    1971-01-01

    Experimental tests were studied for determining the potential uses of future deep space missions in studies of relativistic gravity. The extensions to the parametrized post-Newtonian framework to take explicit account of the solar system's center of mass relative to the mean rest frame of the Universe is reported. Discoveries reported include the Machian effects of motion relative to the universal rest frame. Summaries of the JPL research are included.

  14. Locating Tests and Measurement Instruments for Assessment

    ERIC Educational Resources Information Center

    Mastel, Kristen; Morris-Knower, Jim; Marsalis, Scott

    2016-01-01

    Extension educators, staff, and specialists need to use surveys and other measurement instruments to assess their programming and conduct other research. Challenges in locating tests and measurement tools, however, include lack of time and lack of familiarity with techniques that can be used to find them. This article discusses library resources…

  15. Testing for hypothyroidism in dogs.

    PubMed

    Ferguson, Duncan C

    2007-07-01

    Hypothyroidism is the most common endocrinopathy in the dog. Rather than being a comprehensive review of all possible thyroid function tests, the focus in this article is on the logical progression of test choice, highlighting total thyroxine, free thyroxine, triiodothyronine, thyrotropin (TSH), and antithyroid antibodies. This article includes extensive discussion of the current status of the canine TSH assay and the potential for improving this assay.

  16. "I Don't Know" and Multiple Choice Analysis of Pre- and Post-Tests

    ERIC Educational Resources Information Center

    Spears, Karen; Wilson, Mary

    2010-01-01

    Evaluation is an essential component of any Extension education program. One tool, the pre- and post-test, provides measurable evaluation data. Yet often the answer "I don't know" or all possible answers to a multiple choice question are not included in the repeated measure analysis. Because more than two answers are offered, the test of marginal…

  17. 75 FR 55332 - Determination of Regulatory Review Period for Purposes of Patent Extension; ULORIC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-10

    ... extended for a period of up to 5 years so long as the patented item (human drug product, animal drug... periods of time: A testing phase and an approval phase. For human drug products, the testing phase begins... the length of a regulatory review period for a human drug product will include all of the testing...

  18. 75 FR 53315 - Determination of Regulatory Review Period for Purposes of Patent Extension; ONGLYZA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-31

    ... extended for a period of up to 5 years so long as the patented item (human drug product, animal drug... periods of time: A testing phase and an approval phase. For human drug products, the testing phase begins... the length of a regulatory review period for a human drug product will include all of the testing...

  19. 75 FR 54344 - Determination of Regulatory Review Period for Purposes of Patent Extension; EFFIENT

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-07

    ... extended for a period of up to 5 years so long as the patented item (human drug product, animal drug... periods of time: A testing phase and an approval phase. For human drug products, the testing phase begins... the length of a regulatory review period for a human drug product will include all of the testing...

  20. 75 FR 55331 - Determination of Regulatory Review Period for Purposes of Patent Extension; SAPHRIS

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-10

    ... extended for a period of up to 5 years so long as the patented item (human drug product, animal drug... periods of time: A testing phase and an approval phase. For human drug products, the testing phase begins... the length of a regulatory review period for a human drug product will include all of the testing...

  1. 75 FR 19407 - Determination of Regulatory Review Period for Purposes of Patent Extension; SAVELLA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-14

    ... extended for a period of up to 5 years so long as the patented item (human drug product, animal drug... periods of time: A testing phase and an approval phase. For human drug products, the testing phase begins... the length of a regulatory review period for a human drug product will include all of the testing...

  2. Nondestructive testing techniques

    NASA Astrophysics Data System (ADS)

    Bray, Don E.; McBride, Don

    A comprehensive reference covering a broad range of techniques in nondestructive testing is presented. Based on years of extensive research and application at NASA and other government research facilities, the book provides practical guidelines for selecting the appropriate testing methods and equipment. Topics discussed include visual inspection, penetrant and chemical testing, nuclear radiation, sonic and ultrasonic, thermal and microwave, magnetic and electromagnetic techniques, and training and human factors. (No individual items are abstracted in this volume)

  3. Structural Validity of the Movement ABC-2 Test: Factor Structure Comparisons across Three Age Groups

    ERIC Educational Resources Information Center

    Schulz, Joerg; Henderson, Sheila E.; Sugden, David A.; Barnett, Anna L.

    2011-01-01

    Background: The Movement ABC test is one of the most widely used assessments in the field of Developmental Coordination Disorder (DCD). Improvements to the 2nd edition of the test (M-ABC-2) include an extension of the age range and reduction in the number of age bands as well as revision of tasks. The total test score provides a measure of motor…

  4. Statistical Summary of Missouri Higher Education, 1996-1997.

    ERIC Educational Resources Information Center

    Missouri Coordinating Board for Higher Education, Jefferson City.

    Extensive data tables on higher education in Missouri present information on: the academic preparation of college freshmen (fall 1996), including distribution of American College Testing (ACT) scores and high school rankings; tuition, fees, and financial aid (state and federal, by aid type, including merit-based scholarships) and trends;…

  5. Missouri Higher Education: 1995-1996 Statistical Summary.

    ERIC Educational Resources Information Center

    Missouri State Coordinating Board for Higher Education, Jefferson City.

    Extensive data tables on higher education in Missouri present information on: the academic preparation of college freshmen (fall 1995), including distribution of American College Testing (ACT) scores and high school rankings; tuition, fees, and financial aid (state and federal, by aid type, including merit-based scholarships) and trends;…

  6. Selected Test Items in American History. Bulletin Number 6, Fifth Edition.

    ERIC Educational Resources Information Center

    Anderson, Howard R.; Lindquist, E. F.

    Designed for high school students, this bulletin provides an extensive file of 1,062 multiple-choice questions in American history. Taken largely from the Iowa Every-Pupil Program and the Cooperative Test Service standardized examinations, the questions are chronologically divided into 16 topic areas. They include exploration and discovery;…

  7. Electrophoretic separator for purifying biologicals, part 1

    NASA Technical Reports Server (NTRS)

    Mccreight, L. R.

    1978-01-01

    A program to develop an engineering model of an electrophoretic separator for purifying biologicals is summarized. An extensive mathematical modeling study and numerous ground based tests were included. Focus was placed on developing an actual electrophoretic separator of the continuous flow type, configured and suitable for flight testing as a space processing applications rocket payload.

  8. Fluid Structure Interaction in a Cold Flow Test and Transient CFD Analysis of Out-of-Round Nozzles

    NASA Technical Reports Server (NTRS)

    Ruf, Joseph; Brown, Andrew; McDaniels, David; Wang, Ten-See

    2010-01-01

    This viewgraph presentation describes two nozzle fluid flow interactions. They include: 1) Cold flow nozzle tests with fluid-structure interaction at nozzle separated flow; and 2) CFD analysis for nozzle flow and side loads of nozzle extensions with various out-of-round cases.

  9. Association of body flexibility and carotid atherosclerosis in Japanese middle-aged men: a cross-sectional study

    PubMed Central

    Imoto, Takayuki; Kida, Akira; Yokochi, Takashi; Iwase, Mitsunori; Kozawa, Kenji

    2018-01-01

    Objective This study examined the associations of body flexibility with carotid arterial remodelling, including intima–media thickness (IMT) and plaque formation in middle-aged men. Methods The subjects of this cross-sectional study included 1354 Japanese men aged 35–59 years without histories of stroke or cardiac diseases. The arm extensibility test, which can estimate flexibility of the upper extremity (composed of shoulder external rotation and forearm supination), and the sit-and-reach test were performed. Common carotid IMT and plaque formation (≥1.1 mm) were estimated by ultrasound. Results The proportion of subjects who fully completed the arm extensibility test was 55.0%, and who had plaques in the common carotid artery was 37.8%. IMT was associated with poor arm extensibility (β=–0.073, 95% CI –0.02224 to –0.00041, P=0.004), while plaque formation was associated with poor sit-and-reach (OR 0.98579, 95% CI 0.97257 to 0.99919, P=0.038) after adjustment by all covariates. Conclusions This study demonstrated that poor upper extremity and trunk flexibility were associated with characteristics of early onset of atherosclerosis. Furthermore, these associations were independent of covariates such as age, blood pressure, blood lipids glucose levels and abdominal fat accumulation, handgrip strength and lifestyle, including sleeping, drinking, exercise and smoking habits. Poor flexibility may reflect subclinical atherosclerosis in middle-aged men. PMID:29306892

  10. Utilization of Ancillary Studies in the Cytologic Diagnosis of Respiratory Lesions

    PubMed Central

    Layfield, Lester J.; Roy-Chowdhuri, Sinchita; Baloch, Zubair; Ehya, Hormoz; Geisinger, Kim; Hsiao, Susan J.; Lin, Oscar; Lindeman, Neal I.; Roh, Michael; Schmitt, Fernando; Sidiropoulos, Nikoletta; VanderLaan, Paul A.

    2017-01-01

    The Papanicolaou Society of Cytopathology has developed a set of guidelines for respiratory cytology including indications for sputum examination, bronchial washings and brushings, CT-guided FNA and endobronchial ultrasound guided fine needle aspiration (EBUS-FNA), as well as recommendations for classification and criteria, ancillary testing and post-cytologic diagnosis management and follow-up. All recommendation documents are based on the expertise of committee members, an extensive literature review, and feedback from presentations at national and international conferences. The guideline documents selectively present the results of these discussions. The present document summarizes recommendations for ancillary testing of cytologic samples. Ancillary testing including microbiologic, immunocytochemical, flow cytometric, and molecular testing, including next-generation sequencing are discussed. PMID:27561242

  11. Extensive testing or focused testing of patients with elevated liver enzymes.

    PubMed

    Tapper, Elliot B; Saini, Sameer D; Sengupta, Neil

    2017-02-01

    Many patients have elevated serum aminotransferases reflecting many underlying conditions, both common and rare. Clinicians generally apply one of two evaluative strategies: testing for all diseases at once (extensive) or just common diseases first (focused). We simulated the evaluation of 10,000 adult outpatients with elevated with alanine aminotransferase to compare both testing strategies. Model inputs employed population-based data from the US (National Health and Nutrition Examination Survey) and Britain (Birmingham and Lambeth Liver Evaluation Testing Strategies). Patients were followed until a diagnosis was provided or a diagnostic liver biopsy was considered. The primary outcome was US dollars per diagnosis. Secondary outcomes included doctor visits per diagnosis, false-positives per diagnosis and confirmatory liver biopsies ordered. The extensive testing strategy required the lowest monetary cost, yielding diagnoses for 54% of patients at $448/patient compared to 53% for $502 under the focused strategy. The extensive strategy also required fewer doctor visits (1.35 vs. 1.61 visits/patient). However, the focused strategy generated fewer false-positives (0.1 vs. 0.19/patient) and more biopsies (0.04 vs. 0.08/patient). Focused testing becomes the most cost-effective strategy when accounting for pre-test probabilities and prior evaluations performed. This includes when the respective prevalence of alcoholic, non-alcoholic and drug-induced liver disease exceeds 51.1%, 53.0% and 13.0%. Focused testing is also the most cost-effective strategy in the referral setting where assessments for viral hepatitis, alcoholic and non-alcoholic fatty liver disease have already been performed. Testing for elevated liver enzymes should be deliberate and focused to account for pre-test probabilities if possible. Many patients have elevated liver enzymes reflecting one of many possible liver diseases, some of which are very common and some of which are rare. Tests are widely available for most causes but it is unclear whether clinicians should order them all at once or direct testing based on how likely a given disease may be given the patient's history and physical exam. The tradeoffs of both approaches involve the money spent on testing, number of office visits needed, and false positive results generated. This study shows that if there are no clues available at the time of evaluation, testing all at once saves time and money while causing more false positives. However, if there are strong clues regarding the likelihood of a particular disease, limited testing saves time, money and prevents false positives. Copyright © 2016 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  12. MMS Observatory TV Results Contamination Summary

    NASA Technical Reports Server (NTRS)

    Rosecrans, Glenn; Brieda, Lubos; Errigo, Therese

    2014-01-01

    The Magnetospheric Multiscale (MMS) mission is a constellation of 4 observatories designed to investigate the fundamental plasma physics of reconnection in the Earth's magnetosphere. The various instrument suites measure electric and magnetic fields, energetic particles, and plasma composition. Each spacecraft has undergone extensive environmental testing to prepare it for its minimum 2 year mission. In this paper, we report on the extensive thermal vacuum testing campaign. The testing was performed at the Naval Research Laboratory utilizing the "Big Blue" vacuum chamber. A total of ten thermal vacuum tests were performed, including two chamber certifications, three dry runs, and five tests of the individual MMS observatories. During the test, the observatories were enclosed in a thermal enclosure known as the "hamster cage". The enclosure allowed for a detailed thermal control of various observatory zone, but at the same time, imposed additional contamination and system performance requirements. The environment inside the enclosure and the vacuum chamber was actively monitored by several QCMs, RGA, and up to 18 ion gauges. Each spacecraft underwent a bakeout phase, which was followed by 4 thermal cycles. Unique aspects of the TV campaign included slow pump downs with a partial represses, thruster firings, Helium identification, and monitoring pressure spikes with ion gauges. Selected data from these TV tests is presented along with lessons learned.

  13. A comparison of the views of extension agents and farmers regarding extension education courses in Dezful, Iran

    NASA Astrophysics Data System (ADS)

    Nazarzadeh Zare, Mohsen; Dorrani, Kamal; Gholamali Lavasani, Masoud

    2012-11-01

    Background and purpose : This study examines the views of farmers and extension agents participating in extension education courses in Dezful, Iran, with regard to problems with these courses. It relies upon a descriptive methodology, using a survey as its instrument. Sample : The statistical population consisted of 5060 farmers and 50 extension agents; all extension agents were studied owing to their small population and a sample of 466 farmers was selected based on the stratified ratio sampling method. For the data analysis, statistical procedures including the t-test and factor analysis were used. Results : The results of factor analysis on the views of farmers indicated that these courses have problems such as inadequate use of instructional materials by extension agents, insufficient employment of knowledgeable and experienced extension agents, bad and inconvenient timing of courses for farmers, lack of logical connection between one curriculum and prior ones, negligence in considering the opinions of farmers in arranging the courses, and lack of information about the time of courses. The findings of factor analysis on the views of extension agents indicated that these courses suffer from problems such as use of consistent methods of instruction for teaching curricula, and lack of continuity between courses and their levels and content. Conclusions : Recommendations include: listening to the views of farmers when planning extension courses; providing audiovisual aids, pamphlets and CDs; arranging courses based on convenient timing for farmers; using incentives to encourage participation; and employing extension agents with knowledge of the latest agricultural issues.

  14. CLIPS++: Embedding CLIPS into C++

    NASA Technical Reports Server (NTRS)

    Obermeyer, Lance; Miranker, Daniel P.

    1994-01-01

    This paper describes a set of C++ extensions to the CLIPS language and their embodiment in CLIPS++. These extensions and the implementation approach of CLIPS++ provide a new level of embeddability with C and C++. These extensions are a C++ include statement and a defcontainer construct; (include (c++-header-file.h)) and (defcontainer (c++-type)). The include construct allows C++ functions to be embedded in both the LHS and RHS of CLIPS rules. The header file in an include construct is the same header file the programmer uses for his/her own C++ code, independent of CLIPS. The defcontainer construct allows the inference engine to treat C++ class instances as CLIPS deftemplate facts. Consequently existing C++ class libraries may be transparently imported into CLIPS. These C++ types may use advanced features like inheritance, virtual functions, and templates. The implementation has been tested with several class libraries, including Rogue Wave Software's Tools.h++, GNU's libg++, and USL's C++ Standard Components. The execution speed of CLIPS++ has been determined to be 5 to 700 times the execution speed of CLIPS 6.0 (10 to 20X typical).

  15. Below-Ambient and Cryogenic Thermal Testing

    NASA Technical Reports Server (NTRS)

    Fesmire, James E.

    2016-01-01

    Thermal insulation systems operating in below-ambient temperature conditions are inherently susceptible to moisture intrusion and vapor drive toward the cold side. The subsequent effects may include condensation, icing, cracking, corrosion, and other problems. Methods and apparatus for real-world thermal performance testing of below-ambient systems have been developed based on cryogenic boiloff calorimetry. New ASTM International standards on cryogenic testing and their extension to future standards for below-ambient testing of pipe insulation are reviewed.

  16. Economic and microbiologic evaluation of single-dose vial extension for hazardous drugs.

    PubMed

    Rowe, Erinn C; Savage, Scott W; Rutala, William A; Weber, David J; Gergen-Teague, Maria; Eckel, Stephen F

    2012-07-01

    The update of US Pharmacopeia Chapter <797> in 2008 included guidelines stating that single-dose vials (SDVs) opened and maintained in an International Organization for Standardization Class 5 environment can be used for up to 6 hours after initial puncture. A study was conducted to evaluate the cost of discarding vials after 6 hours and to further test sterility of vials beyond this time point, subsequently defined as the beyond-use date (BUD). Financial determination of SDV waste included 2 months of retrospective review of all doses prescribed. Additionally, actual waste log data were collected. Active and control vials (prepared using sterilized trypticase soy broth) were recovered, instead of discarded, at the defined 6-hour BUD. The institution-specific waste of 19 selected SDV medications discarded at 6 hours was calculated at $766,000 annually, and tracking waste logs for these same medications was recorded at $770,000 annually. Microbiologic testing of vial extension beyond 6 hours showed that 11 (1.86%) of 592 samples had one colony-forming unit on one of two plates. Positive plates were negative at subsequent time points, and all positives were single isolates most likely introduced during the plating process. The cost of discarding vials at 6 hours was significant for hazardous medications in a large academic medical center. On the basis of microbiologic data, vial BUD extension demonstrated a contamination frequency of 1.86%, which likely represented exogenous contamination; vial BUD extension for the tested drugs showed no growth at subsequent time points and could provide an annual cost savings of more than $600,000.

  17. Prevention of distal extension cantilever fracture in mandibular overdentures.

    PubMed

    Quirynen, Thomas; Quirynen, Marc; Duyck, Joke

    2015-09-01

    Fractures of distal bar extensions, supporting a mandibular overdenture, do occur with significant functional and economic consequences for the patient. This study therefore aims to evaluate the effect of different bar cross-sectional shapes and surfaces, bar extension lengths and the placement of a support rib under the distal bar extension on fracture resistance. The 2nd moment area and static strength were calculated for 11 frequently used bar designs using finite element analysis (FEA). For two specific designs (Ackermann round Ø 1.8mm and Dolder-Y macro, the former with and without a support rib) additional physical static and fatigue strength tests were included. The FEA static strength data corresponded well to the 2nd moment area (a similar ranking when maximum allowed force was considered). The application of a rib support (Ackermann Ø 1.8mm) and limitations of the bar extension length (6mm for the Ackermann Ø 1.8mm, 8mm for the Dolder-Y macro) allowed the bars to exceed 5 × 10(6) cycles of 120 and 250N, respectively, before fracture. The region of highest stresses in FEA corresponded well with the locations of the fractures observed in static- and fatigue-testing. With some simple guidelines/modifications, the number of bar extension fractures can be reduced significantly. This study focusses on distal bar extensions which improve the positioning of an implant supported overdenture. By combining laboratory testing and finite element simulations we aim to: (1) explain why fractures occur (dependent on physical characteristics of the bar), and (2) give clinical guidelines on how to prevent such fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Advanced Turbine Technology Applications Project (ATTAP)

    NASA Technical Reports Server (NTRS)

    1989-01-01

    ATTAP activities during the past year were highlighted by an extensive materials assessment, execution of a reference powertrain design, test-bed engine design and development, ceramic component design, materials and component characterization, ceramic component process development and fabrication, component rig design and fabrication, test-bed engine fabrication, and hot gasifier rig and engine testing. Materials assessment activities entailed engine environment evaluation of domestically supplied radial gasifier turbine rotors that were available at the conclusion of the Advanced Gas Turbine (AGT) Technology Development Project as well as an extensive survey of both domestic and foreign ceramic suppliers and Government laboratories performing ceramic materials research applicable to advanced heat engines. A reference powertrain design was executed to reflect the selection of the AGT-5 as the ceramic component test-bed engine for the ATTAP. Test-bed engine development activity focused on upgrading the AGT-5 from a 1038 C (1900 F) metal engine to a durable 1371 C (2500 F) structural ceramic component test-bed engine. Ceramic component design activities included the combustor, gasifier turbine static structure, and gasifier turbine rotor. The materials and component characterization efforts have included the testing and evaluation of several candidate ceramic materials and components being developed for use in the ATTAP. Ceramic component process development and fabrication activities were initiated for the gasifier turbine rotor, gasifier turbine vanes, gasifier turbine scroll, extruded regenerator disks, and thermal insulation. Component rig development activities included combustor, hot gasifier, and regenerator rigs. Test-bed engine fabrication activities consisted of the fabrication of an all-new AGT-5 durability test-bed engine and support of all engine test activities through instrumentation/build/repair. Hot gasifier rig and test-bed engine testing activities were performed.

  19. Does extensive genotyping and nasal potential difference testing clarify the diagnosis of cystic fibrosis among patients with single-organ manifestations of cystic fibrosis?

    PubMed

    Ooi, Chee Y; Dupuis, Annie; Ellis, Lynda; Jarvi, Keith; Martin, Sheelagh; Ray, Peter N; Steele, Leslie; Kortan, Paul; Gonska, Tanja; Dorfman, Ruslan; Solomon, Melinda; Zielenski, Julian; Corey, Mary; Tullis, Elizabeth; Durie, Peter

    2014-03-01

    The phenotypic spectrum of cystic fibrosis (CF) has expanded to include patients affected by single-organ diseases. Extensive genotyping and nasal potential difference (NPD) testing have been proposed to assist in the diagnosis of CF when sweat testing is inconclusive. However, the diagnostic yield of extensive genotyping and NPD and the concordance between NPD and the sweat test have not been carefully evaluated. We evaluated the diagnostic outcomes of genotyping (with 122 mutations included as disease causing), sweat testing and NPD in a prospectively ascertained cohort of undiagnosed patients who presented with chronic sino-pulmonary disease (RESP), chronic/recurrent pancreatitis (PANC) or obstructive azoospermia (AZOOSP). 202 patients (68 RESP, 42 PANC and 92 AZOOSP) were evaluated; 17.3%, 22.8% and 59.9% had abnormal, borderline and normal sweat chloride results, respectively. Only 17 (8.4%) patients were diagnosable as having CF by genotyping. Compared to sweat testing, NPD identified more patients as having CF (33.2%) with fewer borderline results (18.8%). The level of agreement according to kappa statistics (and the observed percentage of agreement) between sweat chloride and NPD in RESP, PANC and AZOOSP subjects was 'moderate' (65% observed agreement), 'poor' (33% observed agreement) and 'fair' (28% observed agreement), respectively. The degree of agreement only improved marginally when subjects with borderline sweat chloride results were excluded from the analysis. The diagnosis of CF or its exclusion is not always straightforward and may remain elusive even with comprehensive evaluation, particularly among individuals who present at an older age with single-organ manifestations suggestive of CF.

  20. Testing the electroweak phase transition in scalar extension models at lepton colliders

    NASA Astrophysics Data System (ADS)

    Cao, Qing-Hong; Huang, Fa-Peng; Xie, Ke-Pan; Zhang, Xinmin

    2018-01-01

    We study the electroweak phase transition in three scalar extension models beyond the Standard Model. Assuming new scalars are decoupled at some heavy scale, we use the covariant derivative expansion method to derive all of the dimension-6 effective operators, whose coefficients are highly correlated in a specific model. We provide bounds to the complete set of dimension-6 operators by including the electroweak precision test and recent Higgs measurements. We find that the parameter space of strong first-order phase transitions (induced by the | H{| }6 operator) can be probed extensively in Zh production at future electron-positron colliders. QHC and KPX are supported in part by the National Science Foundation of China(11175069, 11275009, 11422545), XZ and FPH are supported by the NSFC (11121092, 11033005, 11375202) and also by the CAS Pilot-B program. FPH is also supported by the China Postdoctoral Science Foundation (2016M590133, 2017T100108)

  1. Adaptive DIT-Based Fringe Tracking and Prediction at IOTA

    NASA Technical Reports Server (NTRS)

    Wilson, Edward; Pedretti, Ettore; Bregman, Jesse; Mah, Robert W.; Traub, Wesley A.

    2004-01-01

    An automatic fringe tracking system has been developed and implemented at the Infrared Optical Telescope Array (IOTA). In testing during May 2002, the system successfully minimized the optical path differences (OPDs) for all three baselines at IOTA. Based on sliding window discrete Fourier transform (DFT) calculations that were optimized for computational efficiency and robustness to atmospheric disturbances, the algorithm has also been tested extensively on off-line data. Implemented in ANSI C on the 266 MHZ PowerPC processor running the VxWorks real-time operating system, the algorithm runs in approximately 2.0 milliseconds per scan (including all three interferograms), using the science camera and piezo scanners to measure and correct the OPDs. Preliminary analysis on an extension of this algorithm indicates a potential for predictive tracking, although at present, real-time implementation of this extension would require significantly more computational capacity.

  2. In vitro biomechanical comparison of multistrand cables with conventional cervical stabilization.

    PubMed

    Weis, J C; Cunningham, B W; Kanayama, M; Parker, L; McAfee, P C

    1996-09-15

    The biomechanical stability of six different methods of cervical spine stabilization, three using multistrand cables, were evaluated in a bovine model. To quantify and compare the in vitro biomechanical properties of multistrand cables used for posterior cervical wiring to standard cervical fixation techniques. Fixation of the posterior cervical spine with monofilament stainless steel wire is a proven technique for stabilization of the cervical spine. Recently, multistrand braided cables have been used as a substitute for monofilament stainless steel wires. These cables, made of stainless steel, titanium, or polyethylene, are reported to be stronger, more flexible, and fatigue resistant than are monofilament wire based on mechanical testing. However, no in vitro biomechanical studies have been performed testing a standard posterior cervical wiring technique using multistrand cables. Thirty-six fresh frozen cervical calf spines consistent in size and age were mounted and fixed rigidly to isolate the C4-C5 motion segment. Six different reconstruction techniques were evaluated for Rogers' posterior cervical wiring technique using: 1) 20-gauge stainless steel monofilament wire, 2) stainless steel cable, 3) titanium cable, 4) polyethylene cables, 5) anterior locking plate construct with interbody graft, and 6) posterior plate construct. Six cervical spines were included in each group (n = 6), with each specimen statically evaluated under three stability conditions: 1) intact, 2) reconstructed, and 3) postfatigue. The instability model created before the reconstruction consisted of a distractive flexion Stage 3 injury at C4-C5. Nondestructive static biomechanical testing, performed on an material testing machine (MTS 858 Bionix test system, Minneapolis, MN), included axial compression, axial rotation, flexion-extension, and lateral bending. After reconstruction and static analysis, the specimens were fatigued for 1500 cycles and then statically retested. Data analysis included normalization of the reconstructed and postfatigue data to the intact condition. The calculated static parameters included operative functional unit stiffness and range of motion. Posterior cervical reconstruction with stainless steel monofilament wire proved inadequate under fatigue testing. Two of the six specimens failed with fatigue, and this construct permitted the greatest degree of flexion-extension motion after fatigue in comparison with all other constructs (P < 0.05). There were no significant differences in flexural stiffness or range of motion between stainless steel, titanium, or polyethylene cable constructs before or after fatigue testing. The posterior cervical plate constructs were the stiffest constructs under flexion, extension, and lateral bending modes, before and after fatigue testing (P < 0.05). Multistrand cables were superior to monofilament wire with fatigue testing using an in vitro calf cervical spine model. There were no failures or detectable differences in elongation after fatigue testing between the stainless steel, titanium, and polyethylene cables, as shown by the flexion-extension range of motion. The posterior cervical plate construct offered the greatest stability compared with all other constructs.

  3. In-situ resource utilization activities at the NASA Space Engineering Research Center

    NASA Technical Reports Server (NTRS)

    Ramohalli, Kumar

    1992-01-01

    The paper describes theoretical and experimental research activities at the NASA Space Engineering Research Center aimed at realizing significant cost savings in space missions through the use of locally available resources. The fundamental strategy involves idea generation, scientific screening, feasibility demonstrations, small-scale process plant design, extensive testing, scale-up to realistic production rates, associated controls, and 'packaging', while maintaining sufficient flexibility to respond to national needs in terms of specific applications. Aside from training, the principal activities at the Center include development of a quantitative figure-of-merit to quickly assess the overall mission impact of individual components that constantly change with advancing technologies, extensive tests on a single-cell test bed to produce oxygen from carbon dioxide, and the use of this spent stream to produce methane.

  4. Partnering with School Nutrition Professionals to Promote Fruit and Vegetable Intake through Taste-Testing Activities

    ERIC Educational Resources Information Center

    Cirignano, Sherri M.; Hughes, Luanne J.; Wu-Jung, Corey J.; Morgan, Kathleen; Grenci, Alexandra; Savoca, LeeAnne

    2013-01-01

    The Healthy, Hunger-Free Kids Act (HHFKA) of 2010 sets new nutrition standards for schools, requiring them to serve a greater variety and quantity of fruits and vegetables. Extension educators in New Jersey partnered with school nutrition professionals to implement a school wellness initiative that included taste-testing activities to support…

  5. Radiation Effects on Current Field Programmable Technologies

    NASA Technical Reports Server (NTRS)

    Katz, R.; LaBel, K.; Wang, J. J.; Cronquist, B.; Koga, R.; Penzin, S.; Swift, G.

    1997-01-01

    Manufacturers of field programmable gate arrays (FPGAS) take different technological and architectural approaches that directly affect radiation performance. Similar y technological and architectural features are used in related technologies such as programmable substrates and quick-turn application specific integrated circuits (ASICs). After analyzing current technologies and architectures and their radiation-effects implications, this paper includes extensive test data quantifying various devices total dose and single event susceptibilities, including performance degradation effects and temporary or permanent re-configuration faults. Test results will concentrate on recent technologies being used in space flight electronic systems and those being developed for use in the near term. This paper will provide the first extensive study of various configuration memories used in programmable devices. Radiation performance limits and their impacts will be discussed for each design. In addition, the interplay between device scaling, process, bias voltage, design, and architecture will be explored. Lastly, areas of ongoing research will be discussed.

  6. JT9D ceramic outer air seal system refinement program

    NASA Technical Reports Server (NTRS)

    Gaffin, W. O.

    1982-01-01

    The abradability and durability characteristics of the plasma sprayed system were improved by refinement and optimization of the plasma spray process and the metal substrate design. The acceptability of the final seal system for engine testing was demonstrated by an extensive rig test program which included thermal shock tolerance, thermal gradient, thermal cycle, erosion, and abradability tests. An interim seal system design was also subjected to 2500 endurance test cycles in a JT9D-7 engine.

  7. Immediate effects of neuromuscular joint facilitation intervention after anterior cruciate ligament reconstruction.

    PubMed

    Wang, Lei

    2016-07-01

    [Purpose] The aim of this study was to examine the immediate effects of neuromuscular joint facilitation (NJF) on the functional activity level after rehabilitation of anterior cruciate ligament (ACL) reconstruction. [Subjects and Methods] Ten young subjects (8 males and 2 females) who underwent ACL reconstruction were included in the study. The subjects were divided into two groups, namely, knee joint extension muscle strength training (MST) group and knee joint extension outside rotation pattern of NJF group. Extension strength was measured in both groups before and after the experiment. Surface electromyography (sEMG) of the vastus medialis and vastus lateralis muscles and joint position error (JPE) test of the knee joint were also conducted. [Results] JPE test results and extension strength measurements in the NJF group were improved compared with those in the MST group. Moreover, the average discharge of the vastus medialis and vastus lateralis muscles on sEMG in the NJF group was significantly increased after MST and NJF treatments. [Conclusion] The obtained results suggest that NJF training in patients with ACL reconstruction can improve knee proprioception ability and muscle strength.

  8. Variance change point detection for fractional Brownian motion based on the likelihood ratio test

    NASA Astrophysics Data System (ADS)

    Kucharczyk, Daniel; Wyłomańska, Agnieszka; Sikora, Grzegorz

    2018-01-01

    Fractional Brownian motion is one of the main stochastic processes used for describing the long-range dependence phenomenon for self-similar processes. It appears that for many real time series, characteristics of the data change significantly over time. Such behaviour one can observe in many applications, including physical and biological experiments. In this paper, we present a new technique for the critical change point detection for cases where the data under consideration are driven by fractional Brownian motion with a time-changed diffusion coefficient. The proposed methodology is based on the likelihood ratio approach and represents an extension of a similar methodology used for Brownian motion, the process with independent increments. Here, we also propose a statistical test for testing the significance of the estimated critical point. In addition to that, an extensive simulation study is provided to test the performance of the proposed method.

  9. Association of body flexibility and carotid atherosclerosis in Japanese middle-aged men: a cross-sectional study.

    PubMed

    Suwa, Masataka; Imoto, Takayuki; Kida, Akira; Yokochi, Takashi; Iwase, Mitsunori; Kozawa, Kenji

    2018-01-05

    This study examined the associations of body flexibility with carotid arterial remodelling, including intima-media thickness (IMT) and plaque formation in middle-aged men. The subjects of this cross-sectional study included 1354 Japanese men aged 35-59 years without histories of stroke or cardiac diseases. The arm extensibility test, which can estimate flexibility of the upper extremity (composed of shoulder external rotation and forearm supination), and the sit-and-reach test were performed. Common carotid IMT and plaque formation (≥1.1 mm) were estimated by ultrasound. The proportion of subjects who fully completed the arm extensibility test was 55.0%, and who had plaques in the common carotid artery was 37.8%. IMT was associated with poor arm extensibility (β=-0.073, 95% CI -0.02224 to - 0.00041, P=0.004), while plaque formation was associated with poor sit-and-reach (OR 0.98579, 95% CI 0.97257 to 0.99919, P=0.038) after adjustment by all covariates. This study demonstrated that poor upper extremity and trunk flexibility were associated with characteristics of early onset of atherosclerosis. Furthermore, these associations were independent of covariates such as age, blood pressure, blood lipids glucose levels and abdominal fat accumulation, handgrip strength and lifestyle, including sleeping, drinking, exercise and smoking habits. Poor flexibility may reflect subclinical atherosclerosis in middle-aged men. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. The cross-cultural equivalence of participation instruments: a systematic review.

    PubMed

    Stevelink, S A M; van Brakel, W H

    2013-07-01

    Concepts such as health-related quality of life, disability and participation may differ across cultures. Consequently, when assessing such a concept using a measure developed elsewhere, it is important to test its cultural equivalence. Previous research suggested a lack of cultural equivalence testing in several areas of measurement. This paper reviews the process of cross-cultural equivalence testing of instruments to measure participation in society. An existing cultural equivalence framework was adapted and used to assess participation instruments on five categories of equivalence: conceptual, item, semantic, measurement and operational equivalence. For each category, several aspects were rated, resulting in an overall category rating of 'minimal/none', 'partial' or 'extensive'. The best possible overall study rating was five 'extensive' ratings. Articles were included if the instruments focussed explicitly on measuring 'participation' and were theoretically grounded in the ICIDH(-2) or ICF. Cross-validation articles were only included if it concerned an adaptation of an instrument developed in a high or middle-income country to a low-income country or vice versa. Eight cross-cultural validation studies were included in which five participation instruments were tested (Impact on Participation and Autonomy, London Handicap Scale, Perceived Impact and Problem Profile, Craig Handicap Assessment Reporting Technique, Participation Scale). Of these eight studies, only three received at least two 'extensive' ratings for the different categories of equivalence. The majority of the cultural equivalence ratings given were 'partial' and 'minimal/none'. The majority of the 'none/minimal' ratings were given for item and measurement equivalence. The cross-cultural equivalence testing of the participation instruments included leaves much to be desired. A detailed checklist is proposed for designing a cross-validation study. Once a study has been conducted, the checklist can be used to ensure comprehensive reporting of the validation (equivalence) testing process and its results. • Participation instruments are often used in a different cultural setting than initial developed for. • The conceptualization of participation may vary across cultures. Therefore, cultural equivalence – the extent to which an instrument is equally suitable for use in two or more cultures – is an important concept to address. • This review showed that the process of cultural equivalence testing of the included participation instruments was often addressed insufficiently. • Clinicians should be aware that application of participations instruments in a different culture than initially developed for needs prior testing of cultural validity in the next context.

  11. Benchmark Tests for Stirling Convertor Heater Head Life Assessment Conducted

    NASA Technical Reports Server (NTRS)

    Krause, David L.; Halford, Gary R.; Bowman, Randy R.

    2004-01-01

    A new in-house test capability has been developed at the NASA Glenn Research Center, where a critical component of the Stirling Radioisotope Generator (SRG) is undergoing extensive testing to aid the development of analytical life prediction methodology and to experimentally aid in verification of the flight-design component's life. The new facility includes two test rigs that are performing creep testing of the SRG heater head pressure vessel test articles at design temperature and with wall stresses ranging from operating level to seven times that (see the following photograph).

  12. Childhood Epilepsy and Asthma: A Test of an Extension of the Double ABCX Model.

    ERIC Educational Resources Information Center

    Austin, Joan Kessner

    The Double ABCX Model of Family Adjustment and Adaptation, a model that predicts adaptation to chronic stressors on the family, was extended by dividing it into attitudes, coping, and adaptation of parents and child separately, and by including variables relevant to child adaptation to epilepsy or asthma. The extended model was tested on 246…

  13. A second look at cable logging in the Appalachians

    Treesearch

    Harry G. Gibson; Cleveland J. Biller

    1975-01-01

    Cable logging, once used extensively in the Appalachians, is being re-examined to see if smaller, more mobile systems can help solve some of the timber-managment problems on steep slopes. A small Austrian skyline was tested in West Virginia to determine its feasibility for harvesting enstern hardwoods. The short-term test included both selection and clearcut harvesting...

  14. Capability and flight record of the versatile space shuttle OMS engine

    NASA Astrophysics Data System (ADS)

    Judd, D. Craig

    The development contract for Aerojet's Orbital Manuevering Subsystem (OMS) engine was awarded in February 1974. This paper provides a description of the OMS subcomponents along with a summary of the OMS development program and subsequent flight record. The major subcomponents include the platelet injector, regeneratively cooled chamber, radiation cooled nozzle extension, bipropellant valve, thrust mount, gimbal actuator assembly, and propellant feedlines. The OMS engine underwent an extensive development program between 1974 and 1978 that included approximately 3680 tests performed on 21 separate engines on components for a total duration of more than 19,000 seconds. This was followed with qualification testing of two engines with another 521 tests and 18,504 seconds of hot fire testing. The Space Shuttle system has completed 45 orbital flights with the OMS engines having fired a total of 356 times with a cumulative duration of 38,094 seconds. In all cases, the OMS engine has performed as required because of its maturity, simplicity, and built-in redundancy. Also described are the results of studies performed to increase the performance of the OMS engine either by using LOX/hydrocarbon propellants or by converting to a pump fed system to increase chamber pressure and area ratio.

  15. Economic and Microbiologic Evaluation of Single-Dose Vial Extension for Hazardous Drugs

    PubMed Central

    Rowe, Erinn C.; Savage, Scott W.; Rutala, William A.; Weber, David J.; Gergen-Teague, Maria; Eckel, Stephen F.

    2012-01-01

    Purpose: The update of US Pharmacopeia Chapter <797> in 2008 included guidelines stating that single-dose vials (SDVs) opened and maintained in an International Organization for Standardization Class 5 environment can be used for up to 6 hours after initial puncture. A study was conducted to evaluate the cost of discarding vials after 6 hours and to further test sterility of vials beyond this time point, subsequently defined as the beyond-use date (BUD). Methods: Financial determination of SDV waste included 2 months of retrospective review of all doses prescribed. Additionally, actual waste log data were collected. Active and control vials (prepared using sterilized trypticase soy broth) were recovered, instead of discarded, at the defined 6-hour BUD. Results: The institution-specific waste of 19 selected SDV medications discarded at 6 hours was calculated at $766,000 annually, and tracking waste logs for these same medications was recorded at $770,000 annually. Microbiologic testing of vial extension beyond 6 hours showed that 11 (1.86%) of 592 samples had one colony-forming unit on one of two plates. Positive plates were negative at subsequent time points, and all positives were single isolates most likely introduced during the plating process. Conclusion: The cost of discarding vials at 6 hours was significant for hazardous medications in a large academic medical center. On the basis of microbiologic data, vial BUD extension demonstrated a contamination frequency of 1.86%, which likely represented exogenous contamination; vial BUD extension for the tested drugs showed no growth at subsequent time points and could provide an annual cost savings of more than $600,000. PMID:23180998

  16. Isometric shoulder strength in young swimmers.

    PubMed

    McLaine, Sally J; Ginn, Karen A; Fell, James W; Bird, Marie-Louise

    2018-01-01

    The prevalence of shoulder pain in young swimmers is high. Shoulder rotation strength and the ratio of internal to external rotation strength have been reported as potential modifiable risk factors associated with shoulder pain. However, relative strength measures in elevated positions, which include flexion and extension, have not been established for the young swimmer. The aim of this study was to establish clinically useful, normative shoulder strength measures and ratios for swimmers (14-20 years) without shoulder pain. Cross-sectional, observational study. Swimmers (N=85) without a recent history of shoulder pain underwent strength testing of shoulder flexion and extension (in 140° abduction); and internal and external rotation (in 90° abduction). Strength tests were performed in supine using a hand-held dynamometer and values normalised to body weight. Descriptive statistics were calculated for strength and strength ratios (flexion:extension and internal:external rotation). Differences between groups (based on gender, history of pain, test and arm dominance) were explored using independent and paired t tests. Normative shoulder strength values and ratios were established for young swimmers. There was a significant difference (p<0.002) in relative strength between males and females for all tests with no differences in strength ratios. Relative strength of the dominant and non-dominant shoulders (except for extension); and for swimmers with and without a history of shoulder pain was not significantly different. A normal shoulder strength profile for the young swimmer has been established which provides a valuable reference for the clinician assessing shoulder strength in this population. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Airborne Measurements of Formaldehyde Employing a Tunable Diode Laser Absorption Spectrometer During TRACE-P

    NASA Technical Reports Server (NTRS)

    Fried, Alan; Drummond, James

    2003-01-01

    This final report summarizes the progress achieved over the entire 3-year proposal period including two extensions spanning 1 year. These activities include: 1) Preparation for and participation in the NASA 2001 TRACE-P campaign using our airborne tunable diode laser system to acquire measurements of formaldehyde (CH2O); 2) Comprehensive data analysis and data submittal to the NASA archive; 3) Follow up data interpretation working with NASA modelers to place our ambient CH2O measurements into a broader photochemical context; 4) Publication of numerous JGR papers using this data; 5) Extensive follow up laboratory tests on the selectivity and efficiency of our CH20 scrubbing system; and 6) An extensive follow up effort to assess and study the mechanical stability of our entire optical system, particularly the multipass absorption cell, with aircraft changes in cabin pressure.

  18. Landsat 7 Solar Array Testing Experiences

    NASA Technical Reports Server (NTRS)

    Helfrich, Daniel

    2000-01-01

    This paper covers the extensive Landsat 7 solar array flight qualification testing effort. Details of the mechanical design of the solar array and its retention/release system are presented. A testing chronology is provided beginning with the onset of problems encountered at the subsystem level and carrying through the third and final powered-spacecraft ground deployment test. Design fixes and other changes are explained in the same order as they became necessary to flight-qualify the array. Some interesting lessons learned are included along with key references.

  19. High-Melt Carbon-Carbon Coating for Nozzle Extensions

    NASA Technical Reports Server (NTRS)

    Thompson, James

    2015-01-01

    Carbon-Carbon Advanced Technologies, Inc. (C-CAT), has developed a high-melt coating for use in nozzle extensions in next-generation spacecraft. The coating is composed primarily of carbon-carbon, a carbon-fiber and carbon-matrix composite material that has gained a spaceworthy reputation due to its ability to withstand ultrahigh temperatures. C-CAT's high-melt coating embeds hafnium carbide (HfC) and zirconium diboride (ZrB2) within the outer layers of a carbon-carbon structure. The coating demonstrated enhanced high-temperature durability and suffered no erosion during a test in NASA's Arc Jet Complex. (Test parameters: stagnation heat flux=198 BTD/sq ft-sec; pressure=.265 atm; temperature=3,100 F; four cycles totaling 28 minutes) In Phase I of the project, C-CAT successfully demonstrated large-scale manufacturability with a 40-inch cylinder representing the end of a nozzle extension and a 16-inch flanged cylinder representing the attach flange of a nozzle extension. These demonstrators were manufactured without spalling or delaminations. In Phase II, C-CAT worked with engine designers to develop a nozzle extension stub skirt interfaced with an Aerojet Rocketdyne RL10 engine. All objectives for Phase II were successfully met. Additional nonengine applications for the coating include thermal protection systems (TPS) for next-generation spacecraft and hypersonic aircraft.

  20. A proposal to create an extension to the European baseline series.

    PubMed

    Wilkinson, Mark; Gallo, Rosella; Goossens, An; Johansen, Jeanne D; Rustemeyer, Thomas; Sánchez-Pérez, Javier; Schuttelaar, Marie L; Uter, Wolfgang

    2018-02-01

    The current European baseline series consists of 30 allergens, and was last updated in 2015. To use data from the European Surveillance System on Contact Allergies (ESSCA) to propose an extension to the European baseline series in response to changes in environmental exposures. Data from departmental and national extensions to the baseline series, together with some temporary additions from departments contributing to the ESSCA, were collated during 2013-2014. In total, 31689 patients were patch tested in 46 European departments. Many departments and national groups already consider the current European baseline series to be a suboptimal screen, and use their own extensions to it. The haptens tested are heterogeneous, although there are some consistent themes. Potential haptens to include in an extension to the European baseline series comprise sodium metabisulfite, formaldehyde-releasing preservatives, additional markers of fragrance allergy, propolis, Compositae mix, and 2-hydroxyethyl methacrylate. In combination with other published work from the ESSCA, changes to the current European baseline series are proposed for discussion. As well as addition of the allergens listed above, it is suggested that primin and clioquinol should be deleted from the series, owing to reduced environmental exposure. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Structural, Thermal, and Optical Performance (STOP) Modeling and Results for the James Webb Space Telescope Integrated Science Instrument Module

    NASA Technical Reports Server (NTRS)

    Gracey, Renee; Bartoszyk, Andrew; Cofie, Emmanuel; Comber, Brian; Hartig, George; Howard, Joseph; Sabatke, Derek; Wenzel, Greg; Ohl, Raymond

    2016-01-01

    The James Webb Space Telescope includes the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. We performed extensive structural, thermal, and optical performance(STOP) modeling in support of all phases of ISIM development. In this paper, we focus on modeling and results associated with test and verification. ISIMs test program is bound by ground environments, mostly notably the 1g and test chamber thermal environments. This paper describes STOP modeling used to predict ISIM system performance in 0g and at various on-orbit temperature environments. The predictions are used to project results obtained during testing to on-orbit performance.

  2. Monitoring crack extension in fracture toughness tests by ultrasonics

    NASA Technical Reports Server (NTRS)

    Klima, S. J.; Fisher, D. M.; Buzzard, R. J.

    1975-01-01

    An ultrasonic method was used to observe the onset of crack extension and to monitor continued crack growth in fracture toughness specimens during three point bend tests. A 20 MHz transducer was used with commercially available equipment to detect average crack extension less than 0.09 mm. The material tested was a 300-grade maraging steel in the annealed condition. A crack extension resistance curve was developed to demonstrate the usefulness of the ultrasonic method for minimizing the number of tests required to generate such curves.

  3. Density Deconvolution With EPI Splines

    DTIC Science & Technology

    2015-09-01

    effects of various substances on test subjects [11], [12]. Whereas in geophysics, a shot may be fired into the ground, in pharmacokinetics, a signal is...be significant, including medicine, bioinformatics, chemistry, as- tronomy, and econometrics , as well as an extensive review of kernel based methods...demonstrate the effectiveness of our model in simulations motivated by test instances in [32]. We consider an additive measurement model scenario where

  4. Extended time-interval analysis

    NASA Astrophysics Data System (ADS)

    Fynbo, H. O. U.; Riisager, K.

    2014-01-01

    Several extensions of the halflife analysis method recently suggested by Horvat and Hardy are put forward. Goodness-of-fit testing is included, and the method is extended to cases where more information is available for each decay event which allows applications also for e.g. γ decay data. The results are tested with Monte Carlo simulations and are applied to the decays of 64Cu and 56Mn.

  5. Applying the model of Goal-Directed Behavior, including descriptive norms, to physical activity intentions: A contribution to improving the Theory of Planned Behavior

    USDA-ARS?s Scientific Manuscript database

    The theory of planned behavior (TPB) has received its fair share of criticism lately, including calls for it to retire. We contributed to improving the theory by testing extensions such as the model of goal-directed behavior (MGDB, which adds desire and anticipated positive and negative emotions) ap...

  6. Collisional tests and an extension of the TEMPEST continuum gyrokinetic code

    NASA Astrophysics Data System (ADS)

    Cohen, R. H.; Dorr, M.; Hittinger, J.; Kerbel, G.; Nevins, W. M.; Rognlien, T.; Xiong, Z.; Xu, X. Q.

    2006-04-01

    An important requirement of a kinetic code for edge plasmas is the ability to accurately treat the effect of colllisions over a broad range of collisionalities. To test the interaction of collisions and parallel streaming, TEMPEST has been compared with published analytic and numerical (Monte Carlo, bounce-averaged Fokker-Planck) results for endloss of particles confined by combined electrostatic and magnetic wells. Good agreement is found over a wide range of collisionality, confining potential and mirror ratio, and the required velocity space resolution is modest. We also describe progress toward extension of (4-dimensional) TEMPEST into a ``kinetic edge transport code'' (a kinetic counterpart of UEDGE). The extension includes averaging of the gyrokinetic equations over fast timescales and approximating the averaged quadratic terms by diffusion terms which respect the boundaries of inaccessable regions in phase space. F. Najmabadi, R.W. Conn and R.H. Cohen, Nucl. Fusion 24, 75 (1984); T.D. Rognlien and T.A. Cutler, Nucl. Fusion 20, 1003 (1980).

  7. PANDA asymmetric-configuration passive decay heat removal test results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, O.; Dreier, J.; Aubert, C.

    1997-12-01

    PANDA is a large-scale, low-pressure test facility for investigating passive decay heat removal systems for the next generation of LWRs. In the first series of experiments, PANDA was used to examine the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric (GE) Simplified Boiling Water Reactor (SBWR). The test objectives include concept demonstration and extension of the database available for qualification of containment codes. Also included is the study of the effects of nonuniform distributions of steam and noncondensable gases in the Dry-well (DW) and in the Suppression Chamber (SC). 3 refs., 9 figs.

  8. Reconnaissance of the Nearby Stars

    NASA Technical Reports Server (NTRS)

    Henry, Todd

    1999-01-01

    Accomplishments by the PI during this grant period include: 1. Creating, enhancing, and testing the NStars Database website. During the spring and summer of 1999, the PI performed roughly a dozen extensive "stress tests" of the website. Each test included checking data for individual stars and conducting searches that produced lists of stars from the Database to verify that each entry was correct. In the process, errors were discovered and rectified before the website was made public in July 1999. 2. "Advertising" NStars as a Project to astronomers worldwide. 3. Providing data that has been incorporated into the NStars Database. 4. Observations in Support of the NStars Project.

  9. Advanced Capabilities for Wind Tunnel Testing in the 21st Century

    NASA Technical Reports Server (NTRS)

    Kegelman, Jerome T.; Danehy, Paul M.; Schwartz, Richard J.

    2010-01-01

    Wind tunnel testing methods and test technologies for the 21st century using advanced capabilities are presented. These capabilities are necessary to capture more accurate and high quality test results by eliminating the uncertainties in testing and to facilitate verification of computational tools for design. This paper discusses near term developments underway in ground testing capabilities, which will enhance the quality of information of both the test article and airstream flow details. Also discussed is a selection of new capability investments that have been made to accommodate such developments. Examples include advanced experimental methods for measuring the test gas itself; using efficient experiment methodologies, including quality assurance strategies within the test; and increasing test result information density by using extensive optical visualization together with computed flow field results. These points could be made for both major investments in existing tunnel capabilities or for entirely new capabilities.

  10. Experimental Characterization and Micromechanical Modeling of Woven Carbon/Copper Composites

    NASA Technical Reports Server (NTRS)

    Bednarcyk, Brett A.; Pauly, Christopher C.; Pindera, Marek-Jerzy

    1997-01-01

    The results of an extensive experimental characterization and a preliminary analytical modeling effort for the elastoplastic mechanical behavior of 8-harness satin weave carbon/copper (C/Cu) composites are presented. Previous experimental and modeling investigations of woven composites are discussed, as is the evolution of, and motivation for, the continuing research on C/Cu composites. Experimental results of monotonic and cyclic tension, compression, and Iosipescu shear tests, and combined tension-compression tests, are presented. With regard to the test results, emphasis is placed on the effect of strain gauge size and placement, the effect of alloying the copper matrix to improve fiber-matrix bonding, yield surface characterization, and failure mechanisms. The analytical methodology used in this investigation consists of an extension of the three-dimensional generalized method of cells (GMC-3D) micromechanics model, developed by Aboudi (1994), to include inhomogeneity and plasticity effects on the subcell level. The extension of the model allows prediction of the elastoplastic mechanical response of woven composites, as represented by a true repeating unit cell for the woven composite. The model is used to examine the effects of refining the representative geometry of the composite, altering the composite overall fiber volume fraction, changing the size and placement of the strain gauge with respect to the composite's reinforcement weave, and including porosity within the infiltrated fiber yarns on the in-plane elastoplastic tensile, compressive, and shear response of 8-harness satin C/Cu. The model predictions are also compared with the appropriate monotonic experimental results.

  11. The Development of a Pediatric Inpatient Experience of Care Measure: Child HCAHPS®

    PubMed Central

    Toomey, Sara L.; Zaslavsky, Alan M.; Elliott, Marc N.; Gallagher, Patricia M.; Fowler, Floyd J.; Klein, David J.; Shulman, Shanna; Ratner, Jessica; McGovern, Caitriona; LeBlanc, Jessica L.; Schuster, Mark A.

    2016-01-01

    CMS uses Adult HCAHPS® scores for public reporting and pay-for-performance for most U.S. hospitals, but no publicly available standardized survey of inpatient experience of care exists for pediatrics. To fill the gap, CMS/AHRQ commissioned the development of the Consumer Assessment of Healthcare Providers and Systems Hospital Survey – Child Version (Child HCAHPS), a survey of parents/guardians of pediatric patients (<18 years old) who were recently hospitalized. This Special Article describes the development of Child HCAHPS, which included an extensive review of the literature and quality measures, expert interviews, focus groups, cognitive testing, pilot testing of the draft survey, a national field test with 69 hospitals in 34 states, psychometric analysis, and end-user testing of the final survey. We conducted extensive validity and reliability testing to determine which items would be included in the final survey instrument and to develop composite measures. We analyzed national field test data from 17,727 surveys collected from 11/12-1/14 from parents of recently hospitalized children. The final Child HCAHPS instrument has 62 items, including 39 patient experience items, 10 screeners, 12 demographic/descriptive items, and 1 open-ended item. The 39 experience items are categorized based on testing into 18 composite and single-item measures. Our composite and single-item measures demonstrated good to excellent hospital-level reliability at 300 responses per hospital. Child HCAHPS was developed to be a publicly available standardized survey of pediatric inpatient experience of care. It can be used to benchmark pediatric inpatient experience across hospitals and assist in efforts to improve the quality of inpatient care. PMID:26195542

  12. Subscale Carbon-Carbon Nozzle Extension Development and Hot Fire Testing in Support of Upper Stage Liquid Rocket Engines

    NASA Technical Reports Server (NTRS)

    Gradl, Paul; Valentine, Peter; Crisanti, Matthew; Greene, Sandy Elam

    2016-01-01

    Upper stage and in-space liquid rocket engines are optimized for performance through the use of high area ratio nozzles to fully expand combustion gases to low exit pressures increasing exhaust velocities. Due to the large size of such nozzles and the related engine performance requirements, carbon-carbon (C/C) composite nozzle extensions are being considered for use in order to reduce weight impacts. NASA and industry partner Carbon-Carbon Advanced Technologies (C-CAT) are working towards advancing the technology readiness level of large-scale, domestically-fabricated, C/C nozzle extensions. These C/C extensions have the ability to reduce the overall costs of extensions relative to heritage metallic and composite extensions and to decrease weight by 50%. Material process and coating developments have advanced over the last several years, but hot fire testing to fully evaluate C/C nozzle extensions in relevant environments has been very limited. NASA and C-CAT have designed, fabricated and hot fire tested multiple subscale nozzle extension test articles of various C/C material systems, with the goal of assessing and advancing the manufacturability of these domestically producible materials as well as characterizing their performance when subjected to the typical environments found in a variety of liquid rocket and scramjet engines. Testing at the MSFC Test Stand 115 evaluated heritage and state-of-the-art C/C materials and coatings, demonstrating the capabilities of the high temperature materials and their fabrication methods. This paper discusses the design and fabrication of the 1.2k-lbf sized carbon-carbon nozzle extensions, provides an overview of the test campaign, presents results of the hot fire testing, and discusses potential follow-on development work.

  13. Aggregate freeze-thaw testing and d-cracking field performance : 30 years later : [summary].

    DOT National Transportation Integrated Search

    2014-09-01

    Premature deterioration of concrete pavement due to D-cracking has been a problem in : Kansas since the 1930s. The Kansas Department of Transportation (KDOT) has made : significant efforts, including five extensive studies into the phenomenon of D-Cr...

  14. Assessment of commercial optical amplifiers for potential use in space applications

    NASA Astrophysics Data System (ADS)

    Barbero, Juan; Sotom, Michel; Benazet, Benoit; Esquivias, Ignacio; López Hernández, Francisco José

    2017-11-01

    This paper describes the activities and results of an ESA-funded project concerned with the assessment of optical amplifier technologies and products for applications in fiber optic subsystems of future satellite payloads. On-board applications are briefly introduced, together with associated system-level requirements. Optical amplifier technologies, research achievements and products are reviewed. They are compared in terms of current performance, perspectives and suitability for the target space applications. Optical fibre amplifiers, not limited to Erbium-doped amplifiers, Erbium-doped waveguide amplifiers and Semiconductor Optical Amplifiers are covered. The review includes analysis and trade-off of all performance parameters including saturation output power, noise figure, polarisation maintaining capability, wall-plug efficiency, and mass and size. A selection of optical amplifier products for further evaluation and testing is presented. Results of extensive testing covering both functional performance and environmental behaviour (mechanical, thermal vacuum, radiations) aspects are reported. Most of the work has been completed, but an extension has been proposed for checking and comparing the behaviour of doped fibers under gamma radiation.

  15. Localized cervical facet joint kinematics under physiological and whiplash loading.

    PubMed

    Stemper, Brian D; Yoganandan, Narayan; Gennarelli, Thomas A; Pintar, Frank A

    2005-12-01

    Although facet joints have been implicated in the whiplash injury mechanism, no investigators have determined the degree to which joint motions in whiplash are nonphysiological. The purpose of this investigation was to quantify the correlation between facet joint and segmental motions under physiological and whiplash loading. Human cadaveric cervical spine specimens were exercise tested under physiological extension loading, and intact human head-neck complexes were exercise tested under whiplash loading to correlate the localized component motions of the C4-5 facet joint with segmental extension. Facet joint shear and distraction kinematics demonstrated a linear correlation with segmental extension under both loading modes. Facet joints responded differently to whiplash and physiological loading, with significantly increased kinematics for the same-segmental angulation. The limitations of this study include removal of superficial musculature and the limited sample size for physiological testing. The presence of increased facet joint motions indicated that synovial joint soft-tissue components (that is, synovial membrane and capsular ligament) sustain increased distortion that may subject these tissues to a greater likelihood of injury. This finding is supported by clinical investigations in which lower cervical facet joint injury resulted in similar pain patterns due to the most commonly reported whiplash symptoms.

  16. Wall Boundary Layer Measurements for the NASA Langley Transonic Dynamics Tunnel

    NASA Technical Reports Server (NTRS)

    Wieseman, Carol D.; Bennett, Robert M.

    2007-01-01

    Measurements of the boundary layer parameters in the NASA Langley Transonic Dynamics tunnel were conducted during extensive calibration activities following the facility conversion from a Freon-12 heavy-gas test medium to R-134a. Boundary-layer rakes were mounted on the wind-tunnel walls, ceiling, and floor. Measurements were made over the range of tunnel operation envelope in both heavy gas and air and without a model in the test section at three tunnel stations. Configuration variables included open and closed east sidewall wall slots, for air and R134a test media, reentry flap settings, and stagnation pressures over the full range of tunnel operation. The boundary layer thickness varied considerably for the six rakes. The thickness for the east wall was considerably larger that the other rakes and was also larger than previously reported. There generally was some reduction in thickness at supersonic Mach numbers, but the effect of stagnation pressure, and test medium were not extensive.

  17. Flight test experience and controlled impact of a large, four-engine, remotely piloted airplane

    NASA Technical Reports Server (NTRS)

    Kempel, R. W.; Horton, T. W.

    1985-01-01

    A controlled impact demonstration (CID) program using a large, four engine, remotely piloted transport airplane was conducted. Closed loop primary flight control was performed from a ground based cockpit and digital computer in conjunction with an up/down telemetry link. Uplink commands were received aboard the airplane and transferred through uplink interface systems to a highly modified Bendix PB-20D autopilot. Both proportional and discrete commands were generated by the ground pilot. Prior to flight tests, extensive simulation was conducted during the development of ground based digital control laws. The control laws included primary control, secondary control, and racetrack and final approach guidance. Extensive ground checks were performed on all remotely piloted systems. However, manned flight tests were the primary method of verification and validation of control law concepts developed from simulation. The design, development, and flight testing of control laws and the systems required to accomplish the remotely piloted mission are discussed.

  18. Data Summary Report for the Open Rotor Propulsion Rig Equipped With F31/A31 Rotor Blades

    NASA Technical Reports Server (NTRS)

    Stephens, David

    2014-01-01

    An extensive wind tunnel test campaign was undertaken to quantify the performance and acoustics of a counter-rotating open rotor system. The present document summarizes the portion of this test performed with the so-called Historical Baseline rotor blades, designated F31A31. It includes performance and acoustic data acquired at Mach numbers from take-off to cruise. It also includes the effect of propulsor angle of attack as well as an upstream pylon. This report is accompanied by an electronic data set including relevant acoustic and performance measurements for all of the F31A31 data.

  19. Data Summary Report for the Open Rotor Propulsion Rig Equipped with F31/A31 Rotor Blades

    NASA Technical Reports Server (NTRS)

    Stephens, David B.

    2014-01-01

    An extensive wind tunnel test campaign was undertaken to quantify the performance and acoustics of a counter-rotating open rotor system. The present document summarizes the portion of this test performed with the so-called "Historical Baseline" rotor blades, designated F31/A31. It includes performance and acoustic data acquired at Mach numbers from take-off to cruise. It also includes the effect of propulsor angle of attack as well as an upstream pylon. This report is accompanied by an electronic data set including relevant acoustic and performance measurements for all of the F31/A31 data.

  20. Methods of extending crop signatures from one area to another

    NASA Technical Reports Server (NTRS)

    Minter, T. C. (Principal Investigator)

    1979-01-01

    Efforts to develop a technology for signature extension during LACIE phases 1 and 2 are described. A number of haze and Sun angle correction procedures were developed and tested. These included the ROOSTER and OSCAR cluster-matching algorithms and their modifications, the MLEST and UHMLE maximum likelihood estimation procedures, and the ATCOR procedure. All these algorithms were tested on simulated data and consecutive-day LANDSAT imagery. The ATCOR, OSCAR, and MLEST algorithms were also tested for their capability to geographically extend signatures using LANDSAT imagery.

  1. F-16XL-2 Supersonic Laminar Flow Control Flight Test Experiment

    NASA Technical Reports Server (NTRS)

    Anders, Scott G.; Fischer, Michael C.

    1999-01-01

    The F-16XL-2 Supersonic Laminar Flow Control Flight Test Experiment was part of the NASA High-Speed Research Program. The goal of the experiment was to demonstrate extensive laminar flow, to validate computational fluid dynamics (CFD) codes and design methodology, and to establish laminar flow control design criteria. Topics include the flight test hardware and design, airplane modification, the pressure and suction distributions achieved, the laminar flow achieved, and the data analysis and code correlation.

  2. Kinematic analysis of lumbar and hip motion while rising from a forward, flexed position in patients with and without a history of low back pain.

    PubMed

    McClure, P W; Esola, M; Schreier, R; Siegler, S

    1997-03-01

    This study analyzed two groups of individuals during return to an upright position (extension) from a forward, bent position. Group 1 (n = 12) included individuals with no history of low back pain who were currently asymptomatic, and group 2 (n = 12) included individuals with no history of low back pain. To determine the amount and pattern of lumbar spine and hip motion that occur as an individual rises from a forward, flexed position, to determine if differences exist in this measurement between individuals with and without a history of low back pain, and to determine if hamstring length is related to the pattern of motion. Reports of interaction between lumbar spine and hip movement vary for forward bending and extension. Differences may be a result of variations in measurement methods, loading conditions, or the pathology present, such as low back pain. A three-dimensional optoelectric motion analysis system was used to measure the amount and velocity of lumbar spine and hip motion during extension. Each participant in the study performed three trials of a complete flexion-extension cycle at a self-selected speed. The data for the extension portion of the cycle were averaged and used for statistical analysis. Hamstring length also was determined using two clinical tests, the passive straight-leg raise and the active knee-extension tests. The pattern of movement was described by calculating lumbar to hip extension ratios for each 25% interval of total extension. Individuals with a history of low back pain tended to move from the lumbar spine earlier than those with no history of low back pain, especially in the initial 25% of the extension motion. For all participants, mean lumbar to hip extension ratios were 0.26 for 0-25% of extension, 0.61 for 25-50%, 0.81 for 50-75%, and 2.3 for 75-100%. The lumbar to hip ratios were different in each 25% interval, demonstrating that the hips had a greater contribution to early extension, with the lumbar spine contribution increasing in the middle intervals and becoming the primary source of motion in the final interval. When lumbar to hip extension ratios were compared with corresponding intervals of flexion, three of four were positively correlated to flexion ratios, demonstrating a reversible lumbopelvic rhythm. Although participants with a history of low back pain had significantly tighter hamstrings than participants with no history of low back pain, hamstring length was not correlated with any of the kinematic characteristics during extension. Participants who were currently asymptomatic but had a history of low back pain moved in a manner similar to that of participants with no history of low back pain except that they demonstrated greater lumbar motion and velocity during the initial phase of extension. This may have been the result of low back pain or a contributing factor in recurrent low back pain.

  3. Materials Compatibility Testing in RSRM ODC: Free Cleaner Selection

    NASA Technical Reports Server (NTRS)

    Keen, Jill M.; Sagers, Neil W.; McCool, Alex (Technical Monitor)

    2001-01-01

    Government regulations have mandated production phase-outs of a number of solvents, including 1,1,1-trichloroethane, an ozone-depleting chemical (ODC). This solvent was used extensively in the production of the Reusable Solid Rocket Motors (RSRMs) for the Space Shuttle. Many tests have been performed to identify replacement cleaners. One major area of concern in the selection of a new cleaner has been compatibility. Some specific areas considered included cleaner compatibility with non-metallic surfaces, painted surfaces, support materials such as gloves and wipers as well as corrosive properties of the cleaners on the alloys used on these motors. The intent of this paper is to summarize the test logic, methodology, and results acquired from testing the many cleaner and material combinations.

  4. Fabrication and Testing of Low Cost 2D Carbon-Carbon Nozzle Extensions at NASA/MSFC

    NASA Technical Reports Server (NTRS)

    Greene, Sandra Elam; Shigley, John K.; George, Russ; Roberts, Robert

    2015-01-01

    Subscale liquid engine tests were conducted at NASA/MSFC using a 1.2 Klbf engine with liquid oxygen (LOX) and gaseous hydrogen. Testing was performed for main-stage durations ranging from 10 to 160 seconds at a chamber pressure of 550 psia and a mixture ratio of 5.7. Operating the engine in this manner demonstrated a new and affordable test capability for evaluating subscale nozzles by exposing them to long duration tests. A series of 2D C-C nozzle extensions were manufactured, oxidation protection applied and then tested on a liquid engine test facility at NASA/MSFC. The C-C nozzle extensions had oxidation protection applied using three very distinct methods with a wide range of costs and process times: SiC via Polymer Impregnation & Pyrolysis (PIP), Air Plasma Spray (APS) and Melt Infiltration. The tested extensions were about 6" long with an exit plane ID of about 6.6". The test results, material properties and performance of the 2D C-C extensions and attachment features will be discussed.

  5. Communications for UAS Integration in the NAS Phase 2 Satellite Communications and Terrestrial Extension

    NASA Technical Reports Server (NTRS)

    Griner, Jim; Kerczewski, Bob

    2017-01-01

    In order to provide for the safe integration of unmanned aircraft systems (UAS) into the National Airspace System, the command and control communications link connecting the ground-based pilot with the unmanned aircraft must be highly reliable and robust, with national and international standards to enable interoperability and certification. Both line-of-sight (LOS) links using terrestrial-based communications and beyond-line-of-sight (BLOS) links using satellite communications, supported by national and international standards, are required for integrated UAS operations. The National Aeronautics and Space Administration (NASA) has undertaken an extensive technology development and test program in order to provide the required technical data needed to enable C2 standards development. NASAs UAS Integration in the National Airspace System (NAS), or UAS in the NAS Project, included as a major element the Command and Control Communications (C2) Subproject, based at NASAs Glenn Research Center. The successful first phase of the C2 Subproject, completed during 2012-2016, focused primarily on line-of-sight communications. Accomplishments included air-ground channel propagation characterization and modeling; CNPC prototype radio development; CNPC radio flight testing; satellite communications spectrum study and interference analysis; and development of C2 LOS communications standards development. The second phase of the C2 Subproject will focus primarily on beyond-line-of-sight communications, although a follow-on activity for terrestrial LOS communications, known as Terrestrial Extension, is also included. In addition to the terrestrial element, Phase 2 also includes technology development and testing activities for Ka-Band BLOS C2 Satellite Communications; Ku-Band BLOS C2 Satellite Communications; Ku-Band Interference and Propagation; and C-Band Satellite Communications. This paper will provide brief overviews of the C2 Subproject and its Phase I accomplishments, followed by a description of the plans for the C2 Subproject Phase 2.

  6. Communications for UAS Integration in the NAS Phase 2 - Satellite Communications and Terrestrial Extension

    NASA Technical Reports Server (NTRS)

    Griner, James H.; Kerczewski, Robert J.

    2017-01-01

    In order to provide for the safe integration of unmanned aircraft systems (UAS) into the National Airspace System, the command and control communications link connecting the ground-based pilot with the unmanned aircraft must be highly reliable and robust, with national and international standards to enable interoperability and certification. Both line-of-sight (LOS) links using terrestrial-based communications and beyond-line-of-sight (BLOS) links using satellite communications, supported by national and international standards, are required for integrated UAS operations. The National Aeronautics and Space Administration (NASA) has undertaken an extensive technology development and test program in order to provide the required technical data needed to enable C2 standards development. NASAs UAS Integration in the National Airspace System (NAS), or UAS in the NAS Project, included as a major element the Command and Control Communications (C2) Subproject, based at NASAs Glenn Research Center. The successful first phase of the C2 Subproject, completed during 2012-2016, focused primarily on line-of-sight communications. Accomplishments included air-ground channel propagation characterization and modeling; CNPC prototype radio development; CNPC radio flight testing; satellite communications spectrum study and interference analysis; and development of C2 LOS communications standards development. The second phase of the C2 Subproject will focus primarily on beyond-line-of-sight communications, although a follow-on activity for terrestrial LOS communications, known as Terrestrial Extension, is also included. In addition to the terrestrial element, Phase 2 also includes technology development and testing activities for Ka-Band BLOS C2 Satellite Communications; Ku-Band BLOS C2 Satellite Communications; Ku-Band Interference and Propagation; and C-Band Satellite Communications. This paper will provide brief overviews of the C2 Subproject and its Phase I accomplishments, followed by a description of the plans for the C2 Subproject Phase 2.

  7. A Data Repository and Visualization Toolbox for Metabolic Pathways and PBPK parameter prediction

    EPA Science Inventory

    NHANES is an extensive, well-structured collection of data about hundreds chemicals products of human metabolism and their concentration in human biomarkers, which includes parent to product mapping where known. Together, these data can be used to test the efficacy of application...

  8. Alternatives for jet engine control

    NASA Technical Reports Server (NTRS)

    Sain, M. K.

    1984-01-01

    The technical progress of researches on alternatives for jet engine control is reported. Extensive numerical testing is included. It is indicated that optimal inputs contribute significantly to the process of calculating tensor approximations for nonlinear systems, and that the resulting approximations may be order-reduced in a systematic way.

  9. Laboratory or field tests for evaluating firefighters' work capacity?

    PubMed

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = -0.81) and barbell shoulder press (rs = -0.77), for Pulling: IE shoulder extension (rs = -0.82) and bench press (rs = -0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = -0.83) and bench press (rs = -0.82), and for the Terrain work task: IE trunk flexion (rs = -0.58) and upright barbell row (rs = -0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity.

  10. Thoracic and lumbar spine responses in high-speed rear sled tests.

    PubMed

    Viano, David C; Parenteau, Chantal S; Burnett, Roger

    2018-07-04

    This study analyzed thoracic and lumbar spine responses with in-position and out-of-position (OOP) seated dummies in 40.2 km/h (25 mph) rear sled tests with conventional and all-belts-to-seat (ABTS) seats. Occupant kinematics and spinal responses were determined with modern (≥2000 MY), older (<2000 MY), and ABTS seats. The seats were fixed in a sled buck subjected to a 40.2 km/h (25 mph) rear sled test. The pulse was a 15 g double-peak acceleration with 150 ms duration. The 50th percentile Hybrid III was lap-shoulder belted in the FMVSS 208 design position or OOP, including leaning forward and leaning inboard and forward. There were 26 in-position tests with 11 <2000 MY, 8 ≥2000 MY, and 7 ABTS and 14 OOP tests with 6 conventional and 8 ABTS seats. The dummy was fully instrumented. This study addressed the thoracic and lumbar spine responses. Injury assessment reference values are not approved for the thoracic and lumbar spine. Conservative thresholds exist. The peak responses were normalized by a threshold to compare responses. High-speed video documented occupant kinematics. The extension moments were higher in the thoracic than lumbar spine in the in-position tests. For <2000 MY seats, the thoracic extension moment was 76.8 ± 14.6% of threshold and the lumbar extension moment was 50.5 ± 17.9%. For the ≥2000 MY seats, the thoracic extension moment was 54.2 ± 26.6% of threshold and the lumbar extension moment was 49.8 ± 27.7%. ABTS seats provided similar thoracic and lumbar responses. Modern seat designs lowered thoracic and lumbar responses. For example, the 1996 Taurus had -1,696 N anterior lumbar shear force and -205.2 Nm extension moment. There was -1,184 N lumbar compression force and 1,512 N tension. In contrast, the 2015 F-150 had -500 N shear force and -49.7 Nm extension moment. There was -839 N lumbar compression force and 535 N tension. On average, the 2015 F-150 had 40% lower lumbar spine responses than the 1996 Taurus. The OOP tests had similar peak lumbar responses; however, they occurred later due to the forward lean of the dummy. The design and performance of seats have significantly changed over the past 20 years. Modern seats use a perimeter frame allowing the occupant to pocket into the seatback. Higher and more forward head restraints allow a stronger frame because the head, neck, and torso are more uniformly supported with the seat more upright in severe rear impacts. The overall effect has been a reduction in thoracic and lumbar loads and risks for injury.

  11. Evaluation of fuel injection configurations to control carbon and soot formation in small GT combustors

    NASA Technical Reports Server (NTRS)

    Rosfjord, T. J.; Briehl, D.

    1982-01-01

    An experimental program to investigate hardware configurations which attempt to minimize carbon formation and soot production without sacrificing performance in small gas turbine combustors has been conducted at the United Technologies Research Center. Four fuel injectors, embodying either airblast atomization, pressure atomization, or fuel vaporization techniques, were combined with nozzle air swirlers and injector sheaths, and evaluated at test conditions which included and extended beyond standard small gas turbine combustor operation. Extensive testing was accomplished with configurations embodying either a spill return or a T-vaporizer injector. Minimal carbon deposits were observed on the spill return nozzle for tests using either Jet A or ERBS test fuel. A more extensive film of soft carbon was observed on the vaporizer after operation at standard engine conditions, with large carbonaceous growths forming on the device during off-design operation at low combustor inlet temperature. Test results indicated that smoke emission levels depended on the combustor fluid mechanics (especially the mixing rates near the injector), the atomization quality of the injector and the fuel hydrogen content.

  12. A Retrospective Performance Assessment of the Developmental Neurotoxicity Study in Support of OECD Test Guideline 426

    PubMed Central

    Makris, Susan L.; Raffaele, Kathleen; Allen, Sandra; Bowers, Wayne J.; Hass, Ulla; Alleva, Enrico; Calamandrei, Gemma; Sheets, Larry; Amcoff, Patric; Delrue, Nathalie; Crofton, Kevin M.

    2009-01-01

    Objective We conducted a review of the history and performance of developmental neurotoxicity (DNT) testing in support of the finalization and implementation of Organisation of Economic Co-operation and Development (OECD) DNT test guideline 426 (TG 426). Information sources and analysis In this review we summarize extensive scientific efforts that form the foundation for this testing paradigm, including basic neurotoxicology research, interlaboratory collaborative studies, expert workshops, and validation studies, and we address the relevance, applicability, and use of the DNT study in risk assessment. Conclusions The OECD DNT guideline represents the best available science for assessing the potential for DNT in human health risk assessment, and data generated with this protocol are relevant and reliable for the assessment of these end points. The test methods used have been subjected to an extensive history of international validation, peer review, and evaluation, which is contained in the public record. The reproducibility, reliability, and sensitivity of these methods have been demonstrated, using a wide variety of test substances, in accordance with OECD guidance on the validation and international acceptance of new or updated test methods for hazard characterization. Multiple independent, expert scientific peer reviews affirm these conclusions. PMID:19165382

  13. LOOS: an extensible platform for the structural analysis of simulations.

    PubMed

    Romo, Tod D; Grossfield, Alan

    2009-01-01

    We have developed LOOS (Lightweight Object-Oriented Structure-analysis library) as an object-oriented library designed to facilitate the rapid development of tools for the structural analysis of simulations. LOOS supports the native file formats of most common simulation packages including AMBER, CHARMM, CNS, Gromacs, NAMD, Tinker, and X-PLOR. Encapsulation and polymorphism are used to simultaneously provide a stable interface to the programmer and make LOOS easily extensible. A rich atom selection language based on the C expression syntax is included as part of the library. LOOS enables students and casual programmer-scientists to rapidly write their own analytical tools in a compact and expressive manner resembling scripting. LOOS is written in C++ and makes extensive use of the Standard Template Library and Boost, and is freely available under the GNU General Public License (version 3) LOOS has been tested on Linux and MacOS X, but is written to be portable and should work on most Unix-based platforms.

  14. WSTF Propulsion and Pyrotechnics Corrective Action Test Program Status-2000

    NASA Technical Reports Server (NTRS)

    Saulsberry, R.; Ramirez, J.; Julien, H. L.; Hart, M.; Smith, W.; Bement, L.; Meagher, N. E.

    2000-01-01

    Extensive propulsion and pyrotechnic testing has been in progress at the NASA Johnson Space Center White Sands Test Facility (WSTF) since 1995. This started with the Mars Observer Propulsion and Pyrotechnics Corrective Action Test Program (MOCATP). The MOCATP has concluded, but extensive pyrovalve testing and research and development has continued at WSTF. The capability to accurately analyze and measure pyrovalve combustion product blow-by, evaluate propellant explosions initiated by blow-by, and characterize pyrovalve operation continues to be used and improved. This paper contains an overview of testing since MOCATP inception, but focuses on accomplishments since the status was last reported at the 35th Joint Propulsion Conference, June, 1999. This new activity includes evaluation of 3/8 inch Conax pyrovalves; development and testing of advanced pyrovalve technologies; investigation of nondestructive evaluation techniques to inspect pyrotechnically induced hydrazine explosions both through testing and modeling. Data from this collection of projects are now being formatted into a pyrovalve applications and testing handbook and consensus standard to benefit pyrovalve users and spacecraft designers. The handbook is briefly described here and in more detail in a separate paper. To increase project benefit, pyrovalve manufacturers are encouraged to provide additional valves for testing and consideration, and feedback is encouraged in all aspects of the pyrotechnic projects.

  15. Extensions to the Speech Disorders Classification System (SDCS)

    PubMed Central

    Shriberg, Lawrence D.; Fourakis, Marios; Hall, Sheryl D.; Karlsson, Heather B.; Lohmeier, Heather L.; McSweeny, Jane L.; Potter, Nancy L.; Scheer-Cohen, Alison R.; Strand, Edythe A.; Tilkens, Christie M.; Wilson, David L.

    2010-01-01

    This report describes three extensions to a classification system for pediatric speech sound disorders termed the Speech Disorders Classification System (SDCS). Part I describes a classification extension to the SDCS to differentiate motor speech disorders from speech delay and to differentiate among three subtypes of motor speech disorders. Part II describes the Madison Speech Assessment Protocol (MSAP), an approximately two-hour battery of 25 measures that includes 15 speech tests and tasks. Part III describes the Competence, Precision, and Stability Analytics (CPSA) framework, a current set of approximately 90 perceptual- and acoustic-based indices of speech, prosody, and voice used to quantify and classify subtypes of Speech Sound Disorders (SSD). A companion paper, Shriberg, Fourakis, et al. (2010) provides reliability estimates for the perceptual and acoustic data reduction methods used in the SDCS. The agreement estimates in the companion paper support the reliability of SDCS methods and illustrate the complementary roles of perceptual and acoustic methods in diagnostic analyses of SSD of unknown origin. Examples of research using the extensions to the SDCS described in the present report include diagnostic findings for a sample of youth with motor speech disorders associated with galactosemia (Shriberg, Potter, & Strand, 2010) and a test of the hypothesis of apraxia of speech in a group of children with autism spectrum disorders (Shriberg, Paul, Black, & van Santen, 2010). All SDCS methods and reference databases running in the PEPPER (Programs to Examine Phonetic and Phonologic Evaluation Records; [Shriberg, Allen, McSweeny, & Wilson, 2001]) environment will be disseminated without cost when complete. PMID:20831378

  16. Compressed air demand-type firefighter's breathing system, volume 1. [design analysis and performance tests

    NASA Technical Reports Server (NTRS)

    Sullivan, J. L.

    1975-01-01

    The commercial availability of lightweight high pressure compressed air vessels has resulted in a lightweight firefighter's breathing apparatus. The improved apparatus, and details of its design and development are described. The apparatus includes a compact harness assembly, a backplate mounted pressure reducer assembly, a lightweight bubble-type facemask with a mask mounted demand breathing regulator. Incorporated in the breathing regulator is exhalation valve, a purge valve and a whistle-type low pressure warning that sounds only during inhalation. The pressure reducer assembly includes two pressure reducers, an automatic transfer valve and a signaling device for the low pressure warning. Twenty systems were fabricated, tested, refined through an alternating development and test sequence, and extensively examined in a field evaluation program. Photographs of the apparatus are included.

  17. LDEF electronic systems: Successes, failures, and lessons

    NASA Technical Reports Server (NTRS)

    Miller, Emmett; Porter, Dave; Smith, Dave; Brooks, Larry; Levorsen, Joe; Mulkey, Owen

    1991-01-01

    Following the Long Duration Exposure Facility (LDEF) retrieval, the Systems Special Investigation Group (SIG) participated in an extensive series of tests of various electronic systems, including the NASA provided data and initiate systems, and some experiment systems. Overall, these were found to have performed remarkably well, even though most were designed and tested under limited budgets and used at least some nonspace qualified components. However, several anomalies were observed, including a few which resulted in some loss of data. The postflight test program objectives, observations, and lessons learned from these examinations are discussed. All analyses are not yet complete, but observations to date will be summarized, including the Boeing experiment component studies and failure analysis results related to the Interstellar Gas Experiment. Based upon these observations, suggestions for avoiding similar problems on future programs are presented.

  18. Microleakage of stainless steel crowns placed on intact and extensively destroyed primary first molars: an in vitro study.

    PubMed

    Seraj, Bahman; Shahrabi, Mahdi; Motahari, Pouria; Ahmadi, Rahil; Ghadimi, Sara; Mosharafian, Shahram; Mohammadi, Kaveh; Javad Kharazifard, Mohammad

    2011-01-01

    The purpose of this investigation was to evaluate the effect of residual tooth structure on the microleakage of stainless steel crowns cemented with glass ionomer on primary maxillary and mandibular first molars. Thirty extracted primary molars were divided into 2 groups: group 1 included intact teeth; and group 2 included extensively carious samples. Each tooth received standard preparation, and each crown was luted with G-CEM on its specific specimen. Teeth were loaded vertically and transferred to distilled water. After thermocycling and immersing in methylene blue solution, the teeth were sectioned and examined microscopically for microleakage. Data were analyzed using Mann-Whitney U and Wilcoxon signed-rank tests. All specimens (intact and damaged teeth) had microleakage, although most of these presented only minimum microleakage. No statistically significant differences were found in the microleakage of sound and extensively carious teeth on either the buccal (P=.62) or lingual (P=.65) side. Buccal (P=.73) and lingual (P=.63) surfaces showed similar microleakage scores in primary maxillary and mandibular molars. There was no significant difference in the microleakage of sound or extensively carious teeth and primary maxillary or mandibular first molars.

  19. VETA x ray data acquisition and control system

    NASA Technical Reports Server (NTRS)

    Brissenden, Roger J. V.; Jones, Mark T.; Ljungberg, Malin; Nguyen, Dan T.; Roll, John B., Jr.

    1992-01-01

    We describe the X-ray Data Acquisition and Control System (XDACS) used together with the X-ray Detection System (XDS) to characterize the X-ray image during testing of the AXAF P1/H1 mirror pair at the MSFC X-ray Calibration Facility. A variety of X-ray data were acquired, analyzed and archived during the testing including: mirror alignment, encircled energy, effective area, point spread function, system housekeeping and proportional counter window uniformity data. The system architecture is presented with emphasis placed on key features that include a layered UNIX tool approach, dedicated subsystem controllers, real-time X-window displays, flexibility in combining tools, network connectivity and system extensibility. The VETA test data archive is also described.

  20. Increased Trunk Extension Endurance is Associated with Meaningful Improvement in Balance among Older Adults with Mobility Problems

    PubMed Central

    Suri, Pradeep; Kiely, Dan K.; Leveille, Suzanne G.; Frontera, Walter R.; Bean, Jonathan. F.

    2011-01-01

    Objective To determine if trunk extension endurance changes with training are associated with clinically meaningful improvements in balance among mobility-limited older adults. Design Longitudinal data from a randomized clinical trial. Setting Outpatient rehabilitation research center. Participants Community-dwelling older adults (N=64; mean age 75.9 y) with mobility limitations as defined by a score of 4 to 10 on the Short Physical Performance Battery. Interventions 16 weeks of progressive resistance training. Main Outcome Measures Outcomes were the Berg Balance Scale (BBS) and the Unipedal Stance Test (UST). Predictors included leg strength, leg power, trunk extension endurance and the product of heart rate and blood pressure (RPP) at the final stage of an exercise tolerance test. We performed an analysis of data from participants who completed 16 weeks of training using binary outcomes defined by a clinically meaningful change from baseline to completion of the intervention (CMC) (BBS= 4 units; UST= 5 seconds). The association of predictor variables with balance outcomes was examined separately and together in multivariate adjusted logistic regression models. Results Trunk extension endurance in seconds (1.04 [1.00– 1.09]) was independently associated with CMC on the BBS. Trunk extension endurance (1.02 [1.00– 1.03]) was independently associated with CMC on the UST. Other physical attributes were not associated with meaningful change in balance. Conclusions Improvements in trunk extension endurance were independently associated with clinically meaningful changes in balance in older adults. Leg strength, leg power, and RPP were not associated with CMC in balance. Poor trunk extension endurance may be a rehabilitative impairment worthy of further study as a modifiable factor linked to balance among older adults. PMID:21636073

  1. Pelvic movement strategies and leg extension power in patients with end-stage medial compartment knee osteoarthritis: a cross-sectional study.

    PubMed

    Kierkegaard, Signe; Jørgensen, Peter Bo; Dalgas, Ulrik; Søballe, Kjeld; Mechlenburg, Inger

    2015-09-01

    During movement tasks, patients with medial compartment knee osteoarthritis use compensatory strategies to minimise the joint load of the affected leg. Movement strategies of the knees and trunk have been investigated, but less is known about movement strategies of the pelvis during advancing functional tasks, and how these strategies are associated with leg extension power. The aim of the study was to investigate pelvic movement strategies and leg extension power in patients with end-stage medial compartment knee osteoarthritis compared with controls. 57 patients (mean age 65.6 years) scheduled for medial uni-compartmental knee arthroplasty, and 29 age and gender matched controls were included in this cross-sectional study. Leg extension power was tested with the Nottingham Leg Extension Power-Rig. Pelvic range of motion was derived from an inertia-based measurement unit placed over the sacrum bone during walking, stair climbing and stepping. Patients had lower leg extension power than controls (20-39 %, P < 0.01) and used greater pelvic range of motion during stair and step ascending and descending (P ≤ 0.03, except for pelvic range of motion in the frontal plane during ascending, P > 0.06). Furthermore, an inverse association (coefficient: -0.03 to -0.04; R (2) = 13-22 %) between leg extension power and pelvic range of motion during stair and step descending was found in the patients. Compared to controls, patients with medial compartment knee osteoarthritis use greater pelvic movements during advanced functional performance tests, particularly when these involve descending tasks. Further studies should investigate if it is possible to alter these movement strategies by an intervention aimed at increasing strength and power for the patients.

  2. Maneuver Acoustic Flight Test of the Bell 430 Helicopter

    NASA Technical Reports Server (NTRS)

    Watts, Michael E.; Snider, Royce; Greenwood, Eric; Baden, Joel

    2012-01-01

    A cooperative flight test by NASA, Bell Helicopter and the U.S. Army to characterize the steady state acoustics and measure the maneuver noise of a Bell Helicopter 430 aircraft was accomplished. The test occurred during June/July, 2011 at Eglin Air Force Base, Florida. This test gathered a total of 410 data points over 10 test days and compiled an extensive data base of dynamic maneuver measurements. Three microphone configurations with up to 31 microphones in each configuration were used to acquire acoustic data. Aircraft data included DGPS, aircraft state and rotor state information. This paper provides an overview of the test.

  3. Study made of pneumatic high pressure piping materials /10,000 psi/

    NASA Technical Reports Server (NTRS)

    Loeb, M. B.; Smith, J. C.

    1967-01-01

    Evaluations of five types of steel for use in high pressure pneumatic piping systems include tests for impact strength, tensile and yield strengths, elongation and reduction in area, field weldability, and cost. One type, AISI 4615, was selected as most advantageous for extensive use in future flight vehicles.

  4. INDUSTRIAL RADIOGRAPHY COURSE, INSTRUCTOR'S GUIDE, VOLUME 1.

    ERIC Educational Resources Information Center

    Texas A and M Univ., College Station. Engineering Extension Service.

    THE PURPOSE OF THE GUIDE IS TO GIVE MAXIMUM ASSISTANCE TO INSTRUCTORS IN PLANNING THE TRAINING OF LICENSED INDUSTRIAL RADIOGRAPHERS. IT WAS DEVELOPED BY THE ENGINEERING EXTENSION SERVICE, TEXAS AGRICULTURAL AND MECHANICAL UNIVERSITY, COLLEGE STATION, TEXAS. THE 21 UNITS INCLUDE (1) INDUSTRIAL APPLICATIONS, (2) NONDESTRUCTIVE TESTING METHODS, (3)…

  5. Content and Context: Entropy Principle Experiments in a Course for Non-Science Students

    ERIC Educational Resources Information Center

    Bell, Jerry A.

    1975-01-01

    Describes an approach which begins with observations and systems familiar to the student and proceeds to develop and test models to explain them. Experimental topics include Brownian motion, a germinating cell, phase change of p-dichlorobenzene, extension and contraction of rubber, and an enzyme system. (GS)

  6. Development of a queue warning system utilizing ATM infrastructure system development and field-testing : final report.

    DOT National Transportation Integrated Search

    2017-06-13

    MnDOT has already deployed an extensive infrastructure for Active Traffic Management (ATM) on I-35W and I-94 with plans to expand on other segments of the Twin Cities freeway network. The ATM system includes intelligent lane control signals (ILCS) sp...

  7. PACE: A Browsable Graphical Interface.

    ERIC Educational Resources Information Center

    Beheshti, Jamshid; And Others

    1996-01-01

    Describes PACE (Public Access Catalogue Extension), an alternative interface designed to enhance online catalogs by simulating images of books and library shelves to help users browse through the catalog. Results of a test in a college library against a text-based online public access catalog, including student attitudes, are described.…

  8. Determining Which Dispersants Will Be Effective In Future Deepwater Oil Spills

    EPA Science Inventory

    Deepwater spills result in oil distributed from deep in the water column to the water surface. The objective of this study was to test eight of the available dispersants (including Corexit 9500A, which was used extensively on the 2010 Deepwater Horizon Spill) on South Louisiana C...

  9. OPSAID Initial Design and Testing Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurd, Steven A.; Stamp, Jason Edwin; Chavez, Adrian R.

    2007-11-01

    Process Control System (PCS) security is critical to our national security. Yet, there are a number of technological, economic, and educational impediments to PCS owners implementing effective security on their systems. OPSAID (Open PCS Security Architecture for Interoperable Design), a project sponsored by the US Department of Energy's Office of Electricity Delivery and Reliability, aims to address this issue through developing and testing an open source architecture for PCS security. Sandia National Laboratories, along with a team of PCS vendors and owners, have developed and tested this PCS security architecture. This report describes their progress to date.2 AcknowledgementsThe authors acknowledgemore » and thank their colleagues for their assistance with the OPSAID project.Sandia National Laboratories: Alex Berry, Charles Perine, Regis Cassidy, Bryan Richardson, Laurence PhillipsTeumim Technical, LLC: Dave TeumimIn addition, the authors are greatly indebted to the invaluable help of the members of the OPSAID Core Team. Their assistance has been critical to the success and industry acceptance of the OPSAID project.Schweitzer Engineering Laboratory: Rhett Smith, Ryan Bradetich, Dennis GammelTelTone: Ori Artman Entergy: Dave Norton, Leonard Chamberlin, Mark AllenThe authors would like to acknowledge that the work that produced the results presented in this paper was funded by the U.S. Department of Energy/Office of Electricity Delivery and Energy Reliability (DOE/OE) as part of the National SCADA Test Bed (NSTB) Program. Executive SummaryProcess control systems (PCS) are very important for critical infrastructure and manufacturing operations, yet cyber security technology in PCS is generally poor. The OPSAID (Open PCS (Process Control System) Security Architecture for Interoperable Design) program is intended to address these security shortcomings by accelerating the availability and deployment of comprehensive security technology for PCS, both for existing PCS and inherently secure PCS in the future. All activities are closely linked to industry outreach and advisory efforts.Generally speaking, the OPSAID project is focused on providing comprehensive security functionality to PCS that communicate using IP. This is done through creating an interoperable PCS security architecture and developing a reference implementation, which is tested extensively for performance and reliability.This report first provides background on the PCS security problem and OPSAID, followed by goals and objectives of the project. The report also includes an overview of the results, including the OPSAID architecture and testing activities, along with results from industry outreach activities. Conclusion and recommendation sections follow. Finally, a series of appendices provide more detailed information regarding architecture and testing activities.Summarizing the project results, the OPSAID architecture was defined, which includes modular security functionality and corresponding component modules. The reference implementation, which includes the collection of component modules, was tested extensively and proved to provide more than acceptable performance in a variety of test scenarios. The primary challenge in implementation and testing was correcting initial configuration errors.OPSAID industry outreach efforts were very successful. A small group of industry partners were extensively involved in both the design and testing of OPSAID. Conference presentations resulted in creating a larger group of potential industry partners.Based upon experience implementing and testing OPSAID, as well as through collecting industry feedback, the OPSAID project has done well and is well received. Recommendations for future work include further development of advanced functionality, refinement of interoperability guidance, additional laboratory and field testing, and industry outreach that includes PCS owner education. 4 5 --This page intentionally left blank --« less

  10. Isometric abdominal wall muscle strength assessment in individuals with incisional hernia: a prospective reliability study.

    PubMed

    Jensen, K K; Kjaer, M; Jorgensen, L N

    2016-12-01

    To determine the reliability of measurements obtained by the Good Strength dynamometer, determining isometric abdominal wall and back muscle strength in patients with ventral incisional hernia (VIH) and healthy volunteers with an intact abdominal wall. Ten patients with VIH and ten healthy volunteers with an intact abdominal wall were each examined twice with a 1 week interval. Examination included the assessment of truncal flexion and extension as measured with the Good Strength dynamometer, the completion of the International Physical Activity Questionnaire (IPAQ) and the self-assessment of truncal strength on a visual analogue scale (SATS). The test-retest reliability of truncal flexion and extension was assessed by interclass correlation coefficient (ICC), and Bland and Altman graphs. Finally, correlations between truncal strength, and IPAQ and SATS were examined. Truncal flexion and extension showed excellent test-retest reliability for both patients with VIH (ICC 0.91 and 0.99) and healthy controls (ICC 0.97 and 0.96). Bland and Altman plots showed that no systematic bias was present for neither truncal flexion nor extension when assessing reliability. For patients with VIH, no significant correlations between objective measures of truncal strength and IPAQ or SATS were found. For healthy controls, both truncal flexion (τ 0.58, p = 0.025) and extension (τ 0.58, p = 0.025) correlated significantly with SATS, while no other significant correlation between truncal strength measures and IPAQ was found. The Good Strength dynamometer provided a reliable, low-cost measure of truncal flexion and extension in patients with VIH.

  11. Hybrid testing of lumbar CHARITE discs versus fusions.

    PubMed

    Panjabi, Manohar; Malcolmson, George; Teng, Edward; Tominaga, Yasuhiro; Henderson, Gweneth; Serhan, Hassan

    2007-04-20

    An in vitro human cadaveric biomechanical study. To quantify effects on operated and other levels, including adjacent levels, due to CHARITE disc implantations versus simulated fusions, using follower load and the new hybrid test method in flexion-extension and bilateral torsion. Spinal fusion has been associated with long-term accelerated degeneration at adjacent levels. As opposed to the fusion, artificial discs are designed to preserve motion and diminish the adjacent-level effects. Five fresh human cadaveric lumbar specimens (T12-S1) underwent multidirectional testing in flexion-extension and bilateral torsion with 400 N follower load. Intact specimen total ranges of motion were determined with +/-10 Nm unconstrained pure moments. The intact range of motion was used as input for the hybrid tests of 5 constructs: 1) CHARITE disc at L5-S1; 2) fusion at L5-S1; 3) CHARITE discs at L4-L5 and L5-S1; 4) CHARITE disc at L4-L5 and fusion at L5-S1; and 5) 2-level fusion at L4-L5-S1. Using repeated-measures single factor analysis of variance and Bonferroni statistical tests (P < 0.05), intervertebral motion redistribution of each construct was compared with the intact. In flexion-extension, 1-level CHARITE disc preserved motion at the operated and other levels, while 2-level CHARITE showed some amount of other-level effects. In contrast, 1- and 2-level fusions increased other-level motions (average, 21.0% and 61.9%, respectively). In torsion, both 1- and 2-level discs preserved motions at all levels. The 2-level simulated fusion increased motions at proximal levels (22.9%), while the 1-level fusion produced no significant changes. In general, CHARITE discs preserved operated- and other-level motions. Fusion simulations affected motion redistribution at other levels, including adjacent levels.

  12. Liquid propulsion turbomachinery model testing

    NASA Technical Reports Server (NTRS)

    Mcdaniels, David M.; Snellgrove, Lauren M.

    1992-01-01

    For the past few years an extensive experimental program to understand the fluid dynamics of the Space Shuttle Main Engine hot gas manifold has been in progress. This program includes models of the Phase II and II+ manifolds for each of the air and water flow facilities, as well as two different turbine flow paths and two simulated power levels for each manifold. All models are full-scale (geometric). The water models are constructed partially of acrylic to allow flow visualization. The intent of this paper is to discuss the concept, including the test objectives, facilities, and models, and to summarize the data for an example configuration, including static pressure data, flow visualization, and the solution of a specific flow problem.

  13. Development of protocols for confined extension/creep testing of geosynthetics for highway applications

    DOT National Transportation Integrated Search

    1998-03-01

    This report presents the development and verification of a testing protocol and protocol equipment for confined extension testing and confined creep testing for geosynthetic reinforcement materials. The developed data indicate that confined response ...

  14. Identification of the soluble HVP-associated antigen of the lymphoblastoid cell line established from lymphomatous baboon (Papio hamadryas).

    PubMed

    Voevodin, A F; Lapin, B A; Agrba, V Z; Timanovskaya, V V

    1978-01-01

    A new technique (indirect double immunodiffusion) for detection of EBV-associated soluble antigen and corresponding antibodies has been developed. This technique includes three steps: 1) simple double immunodiffusion with extracts of Raji cells (or other EBV-genome positive cells) and human sera containing antibodies against EBV-associated soluble antigen; 2) extensive washing and treatment with anti-human globulin; 3) extensive washing and treatment with tannic acid. Using this test it was shown that the soluble antigen indistinguishable from EBV-associated soluble antigen was present in KMPG-1 cells producing HVP.

  15. A 5-kW xenon ion thruster lifetest

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.; Verhey, Timothy R.

    1990-01-01

    The results of the first life test of a high power ring-cusp ion thruster are presented. A 30-cm laboratory model thruster was operated steady-state at a nominal beam power of 5 kW on xenon propellant for approximately 900 hours. This test was conducted to identify life-timing erosion modifications, and to demonstrate operation using simplified power processing. The results from this test are described including the conclusions derived from extensive post-test analyses of the thruster. Modifications to the thruster and ground support equipment, which were incorporated to solve problems identified by the lifetest, are also described.

  16. Real-time maritime scene simulation for ladar sensors

    NASA Astrophysics Data System (ADS)

    Christie, Chad L.; Gouthas, Efthimios; Swierkowski, Leszek; Williams, Owen M.

    2011-06-01

    Continuing interest exists in the development of cost-effective synthetic environments for testing Laser Detection and Ranging (ladar) sensors. In this paper we describe a PC-based system for real-time ladar scene simulation of ships and small boats in a dynamic maritime environment. In particular, we describe the techniques employed to generate range imagery accompanied by passive radiance imagery. Our ladar scene generation system is an evolutionary extension of the VIRSuite infrared scene simulation program and includes all previous features such as ocean wave simulation, the physically-realistic representation of boat and ship dynamics, wake generation and simulation of whitecaps, spray, wake trails and foam. A terrain simulation extension is also under development. In this paper we outline the development, capabilities and limitations of the VIRSuite extensions.

  17. Space shuttle phase B wind tunnel model and test information. Volume 3: Launch configuration

    NASA Technical Reports Server (NTRS)

    Glynn, J. L.; Poucher, D. E.

    1988-01-01

    Archived wind tunnel test data are available for flyback booster or other alternate recoverable configuration as well as reusable orbiters studied during initial development (Phase B) of the Space Shuttle, including contractor data for an extensive variety of configurations with an array of wing and body planforms. The test data have been compiled into a database and are available for application to current winged flyback or recoverable booster aerodynamic studies. The Space Shuttle Phase B Wind Tunnel Database is structured by vehicle component and configuration. Basic components include booster, orbiter, and launch vehicle. Booster configuration types include straight and delta wings, canard, cylindrical, retroglide and twin body. Orbiter configurations include straight and delta wings, lifting body, drop tanks and double delta wings. Launch configurations include booster and orbiter components in various stacked and tandem combinations. The digital database consists of 220 files containing basic tunnel data. Database structure is documented in a series of reports which include configuration sketches for the various planforms tested. This is Volume 3 -- launch configurations.

  18. Maneuver Acoustic Flight Test of the Bell 430 Helicopter Data Report

    NASA Technical Reports Server (NTRS)

    Watts, Michael E.; Greenwood, Eric; Smith, Charles D.; Snider, Royce; Conner, David A.

    2014-01-01

    A cooperative ight test by NASA, Bell Helicopter and the U.S. Army to characterize the steady state acoustics and measure the maneuver noise of a Bell Helicopter 430 aircraft was accomplished. The test occurred during June/July 2011 at Eglin Air Force Base, Florida. This test gathered a total of 410 test points over 10 test days and compiled an extensive database of dynamic maneuver measurements. Three microphone arrays with up to 31 microphon. es in each were used to acquire acoustic data. Aircraft data included Differential Global Positioning System, aircraft state and rotor state information. This paper provides an overview of the test and documents the data acquired.

  19. Manual muscle testing and hand-held dynamometry in people with inflammatory myopathy: An intra- and interrater reliability and validity study

    PubMed Central

    Baschung Pfister, Pierrette; Sterkele, Iris; Maurer, Britta; de Bie, Rob A.; Knols, Ruud H.

    2018-01-01

    Manual muscle testing (MMT) and hand-held dynamometry (HHD) are commonly used in people with inflammatory myopathy (IM), but their clinimetric properties have not yet been sufficiently studied. To evaluate the reliability and validity of MMT and HHD, maximum isometric strength was measured in eight muscle groups across three measurement events. To evaluate reliability of HHD, intra-class correlation coefficients (ICC), the standard error of measurements (SEM) and smallest detectable changes (SDC) were calculated. To measure reliability of MMT linear Cohen`s Kappa was computed for single muscle groups and ICC for total score. Additionally, correlations between MMT8 and HHD were evaluated with Spearman Correlation Coefficients. Fifty people with myositis (56±14 years, 76% female) were included in the study. Intra-and interrater reliability of HHD yielded excellent ICCs (0.75–0.97) for all muscle groups, except for interrater reliability of ankle extension (0.61). The corresponding SEMs% ranged from 8 to 28% and the SDCs% from 23 to 65%. MMT8 total score revealed excellent intra-and interrater reliability (ICC>0.9). Intrarater reliability of single muscle groups was substantial for shoulder and hip abduction, elbow and neck flexion, and hip extension (0.64–0.69); moderate for wrist (0.53) and knee extension (0.49) and fair for ankle extension (0.35). Interrater reliability was moderate for neck flexion (0.54) and hip abduction (0.44); fair for shoulder abduction, elbow flexion, wrist and ankle extension (0.20–0.33); and slight for knee extension (0.08). Correlations between the two tests were low for wrist, knee, ankle, and hip extension; moderate for elbow flexion, neck flexion and hip abduction; and good for shoulder abduction. In conclusion, the MMT8 total score is a reliable assessment to consider general muscle weakness in people with myositis but not for single muscle groups. In contrast, our results confirm that HHD can be recommended to evaluate strength of single muscle groups. PMID:29596450

  20. Extensible byssus of Pinctada fucata: Ca2+-stabilized nanocavities and a thrombospondin-1 protein

    NASA Astrophysics Data System (ADS)

    Liu, Chuang; Li, Shiguo; Huang, Jingliang; Liu, Yangjia; Jia, Ganchu; Xie, Liping; Zhang, Rongqing

    2015-10-01

    The extensible byssus is produced by the foot of bivalve animals, including the pearl oyster Pinctada fucata, and enables them to attach to hard underwater surfaces. However, the mechanism of their extensibility is not well understood. To understand this mechanism, we analyzed the ultrastructure, composition and mechanical properties of the P. fucata byssus using electron microscopy, elemental analysis, proteomics and mechanical testing. In contrast to the microstructures of Mytilus sp. byssus, the P. fucata byssus has an exterior cuticle without granules and an inner core with nanocavities. The removal of Ca2+ by ethylenediaminetetraacetic acid (EDTA) treatment expands the nanocavities and reduces the extensibility of the byssus, which is accompanied by a decrease in the β-sheet conformation of byssal proteins. Through proteomic methods, several proteins with antioxidant and anti-corrosive properties were identified as the main components of the distal byssus regions. Specifically, a protein containing thrombospondin-1 (TSP-1), which is highly expressed in the foot, is hypothesized to be responsible for byssus extensibility. Together, our findings demonstrate the importance of inorganic ions and multiple proteins for bivalve byssus extension, which could guide the future design of biomaterials for use in seawater.

  1. Extensible byssus of Pinctada fucata: Ca2+-stabilized nanocavities and a thrombospondin-1 protein

    PubMed Central

    Liu, Chuang; Li, Shiguo; Huang, Jingliang; Liu, Yangjia; Jia, Ganchu; Xie, Liping; Zhang, Rongqing

    2015-01-01

    The extensible byssus is produced by the foot of bivalve animals, including the pearl oyster Pinctada fucata, and enables them to attach to hard underwater surfaces. However, the mechanism of their extensibility is not well understood. To understand this mechanism, we analyzed the ultrastructure, composition and mechanical properties of the P. fucata byssus using electron microscopy, elemental analysis, proteomics and mechanical testing. In contrast to the microstructures of Mytilus sp. byssus, the P. fucata byssus has an exterior cuticle without granules and an inner core with nanocavities. The removal of Ca2+ by ethylenediaminetetraacetic acid (EDTA) treatment expands the nanocavities and reduces the extensibility of the byssus, which is accompanied by a decrease in the β-sheet conformation of byssal proteins. Through proteomic methods, several proteins with antioxidant and anti-corrosive properties were identified as the main components of the distal byssus regions. Specifically, a protein containing thrombospondin-1 (TSP-1), which is highly expressed in the foot, is hypothesized to be responsible for byssus extensibility. Together, our findings demonstrate the importance of inorganic ions and multiple proteins for bivalve byssus extension, which could guide the future design of biomaterials for use in seawater. PMID:26446436

  2. Liquids and homemade explosive detection

    NASA Astrophysics Data System (ADS)

    Ellenbogen, Michael; Bijjani, Richard

    2009-05-01

    Excerpt from the US Transportation Security Agency website: "The ban on liquids, aerosols and gels was implemented on August 10 after a terrorist plot was foiled. Since then, experts from around the government, including the FBI and our national labs have analyzed the information we now have and have conducted extensive explosives testing to get a better understanding of this specific threat." In order to lift the ban and ease the burden on the flying public, Reveal began an extensive effort in close collaboration with the US and several other governments to help identify these threats. This effort resulted in the successful development and testing of an automated explosive detection system capable of resolving these threats with a high probability of detection and a low false alarm rate. We will present here some of the methodology and approach we took to address this problem.

  3. Results from the Operational Testing of the Eaton Smart Grid Capable Electric Vehicle Supply Equipment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, Brion

    2014-10-01

    The Idaho National Laboratory conducted testing and analysis of the Eaton smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Eaton for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Eaton smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormalmore » conditions testing, and charging of a plug-in vehicle.« less

  4. Results from Operational Testing of the Siemens Smart Grid-Capable Electric Vehicle Supply Equipment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, Brion

    2015-05-01

    The Idaho National Laboratory conducted testing and analysis of the Siemens smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Siemens for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Siemens smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormalmore » conditions testing, and charging of a plug-in vehicle.« less

  5. Algorithm and code development for unsteady three-dimensional Navier-Stokes equations

    NASA Technical Reports Server (NTRS)

    Obayashi, Shigeru

    1991-01-01

    A streamwise upwind algorithm for solving the unsteady 3-D Navier-Stokes equations was extended to handle the moving grid system. It is noted that the finite volume concept is essential to extend the algorithm. The resulting algorithm is conservative for any motion of the coordinate system. Two extensions to an implicit method were considered and the implicit extension that makes the algorithm computationally efficient is implemented into Ames's aeroelasticity code, ENSAERO. The new flow solver has been validated through the solution of test problems. Test cases include three-dimensional problems with fixed and moving grids. The first test case shown is an unsteady viscous flow over an F-5 wing, while the second test considers the motion of the leading edge vortex as well as the motion of the shock wave for a clipped delta wing. The resulting algorithm has been implemented into ENSAERO. The upwind version leads to higher accuracy in both steady and unsteady computations than the previously used central-difference method does, while the increase in the computational time is small.

  6. Flight test experience and controlled impact of a remotely piloted jet transport aircraft

    NASA Technical Reports Server (NTRS)

    Horton, Timothy W.; Kempel, Robert W.

    1988-01-01

    The Dryden Flight Research Center Facility of NASA Ames Research Center (Ames-Dryden) and the FAA conducted the controlled impact demonstration (CID) program using a large, four-engine, remotely piloted jet transport airplane. Closed-loop primary flight was controlled through the existing onboard PB-20D autopilot which had been modified for the CID program. Uplink commands were sent from a ground-based cockpit and digital computer in conjunction with an up-down telemetry link. These uplink commands were received aboard the airplane and transferred through uplink interface systems to the modified PB-20D autopilot. Both proportional and discrete commands were produced by the ground system. Prior to flight tests, extensive simulation was conducted during the development of ground-based digital control laws. The control laws included primary control, secondary control, and racetrack and final approach guidance. Extensive ground checks were performed on all remotely piloted systems; however, piloted flight tests were the primary method and validation of control law concepts developed from simulation. The design, development, and flight testing of control laws and systems required to accomplish the remotely piloted mission are discussed.

  7. Ceramic and coating applications in the hostile environment of a high temperature hypersonic wind tunnel. [Langley 8-foot high temperature structures tunnel

    NASA Technical Reports Server (NTRS)

    Puster, R. L.; Karns, J. R.; Vasquez, P.; Kelliher, W. C.

    1981-01-01

    A Mach 7, blowdown wind tunnel was used to investigate aerothermal structural phenomena on large to full scale high speed vehicle components. The high energy test medium, which provided a true temperature simulation of hypersonic flow at 24 to 40 km altitude, was generated by the combustion of methane with air at high pressures. Since the wind tunnel, as well as the models, must be protected from thermally induced damage, ceramics and coatings were used extensively. Coatings were used both to protect various wind tunnel components and to improve the quality of the test stream. Planned modifications for the wind tunnel included more extensive use of ceramics in order to minimize the number of active cooling systems and thus minimize the inherent operational unreliability and cost that accompanies such systems. Use of nonintrusive data acquisition techniques, such as infrared radiometry, allowed more widespread use of ceramics for models to be tested in high energy wind tunnels.

  8. Competency Based Curriculum Guide for Practical Nursing Education in Virginia. Final Report.

    ERIC Educational Resources Information Center

    Old Dominion Univ., Norfolk, VA. Dept. of Industrial Arts Education.

    This final report contains a three-page narrative and extensive appendixes, including correspondence, surveys, field test evaluation and guide, and the Competency-Based Curriculum Guide for Practical Nursing Education in Virginia developed by the project. The over 200-page curriculum guide presents a suggested master curriculum for a twelve or…

  9. Children's Evaluative Categories and Inductive Inferences within the Domain of Food

    ERIC Educational Resources Information Center

    Nguyen, Simone P.

    2008-01-01

    Evaluative categories include items that share the same value-laden assessment. Given that these categories have not been examined extensively within the child concepts literature, the present research explored evaluative categorization and induction within the domain of food as a test case. Specifically, two studies examined the categories of…

  10. CMOS array design automation techniques. [metal oxide semiconductors

    NASA Technical Reports Server (NTRS)

    Ramondetta, P.; Feller, A.; Noto, R.; Lombardi, T.

    1975-01-01

    A low cost, quick turnaround technique for generating custom metal oxide semiconductor arrays using the standard cell approach was developed, implemented, tested and validated. Basic cell design topology and guidelines are defined based on an extensive analysis that includes circuit, layout, process, array topology and required performance considerations particularly high circuit speed.

  11. Performance of the S - [chi][squared] Statistic for Full-Information Bifactor Models

    ERIC Educational Resources Information Center

    Li, Ying; Rupp, Andre A.

    2011-01-01

    This study investigated the Type I error rate and power of the multivariate extension of the S - [chi][squared] statistic using unidimensional and multidimensional item response theory (UIRT and MIRT, respectively) models as well as full-information bifactor (FI-bifactor) models through simulation. Manipulated factors included test length, sample…

  12. Discovery Curriculum: For Use with Middle Grade Students in or out of the Classroom.

    ERIC Educational Resources Information Center

    Wickless, Mimi

    This teaching guide contains the Discovery Curriculum which was extensively field tested at The National Arbor Day Foundation's Discovery Camp. The Discovery Curriculum is designed to promote wise environmental stewardship through relevant, active learning opportunities. Goals for each participant include: (1) be aware of and able to cite examples…

  13. Solar Cell Efficiency Tables (Version 51)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levi, Dean H; Green, Martin A.; Hishikawa, Yoshihiro

    Consolidated tables showing an extensive listing of the highest independently confirmed efficiencies for solar cells and modules are presented. Guidelines for inclusion of results into these tables are outlined and new entries since July 2017 are reviewed, together with progress over the last 25 years. Appendices are included documenting area definitions and also listing recognised test centres.

  14. Field testing existence values for riparian ecosystems

    Treesearch

    John W. Duffield; Chris J. Neher; David A. Patterson; Patricia A. Champ

    2007-01-01

    This paper presents preliminary findings on a cash and contingent valuation (cv) experiment. The study replicates major elements of an earlier (1990) experiment, which solicited hypothetical and actual donations to benefit instream flows for Montana fisheries. Extensions of the earlier work include: repeat contacts to increase response rate, follow-up of the contingent...

  15. 76 FR 17755 - Energy Conservation Program for Consumer Products: Decision and Order Granting 180-Day Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-31

    ... standby mode and off mode energy consumption of those products. The petitioners demonstrated that meeting... energy consumption. 75 FR 64621. More specifically, this test procedure final rule included a standby... ae ) for gas or oil-fired furnaces or boilers and annual electric energy consumption (E e ) for...

  16. Decentralization and Educational Performance: Evidence from the PROHECO Community School Program in Rural Honduras

    ERIC Educational Resources Information Center

    Di Gropello, Emanuela; Marshall, Jeffery H.

    2011-01-01

    We analyze the effectiveness of the Programa Hondureno de Educacion Comunitaria (PROHECO) community school program in rural Honduras. The data include standardized tests and extensive information on school, teacher, classroom and community features for 120 rural schools drawn from 15 states. Using academic achievement decompositions we find that…

  17. PISA, Policymaking and Political Pantomime: Education Policy Referencing between England and Hong Kong

    ERIC Educational Resources Information Center

    Adamson, Bob; Forestier, Katherine; Morris, Paul; Han, Christine

    2017-01-01

    Since the mid-1980s, a number of East Asian societies have consistently performed well in international tests, and their education systems have emerged as models of "best practice", including Hong Kong, which has been extensively referenced by politicians and their advisers in England. In parallel, local dissatisfaction with the…

  18. Hydra, a model system for environmental studies.

    PubMed

    Quinn, Brian; Gagné, François; Blaise, Christian

    2012-01-01

    Hydra have been extensively used for studying the teratogenic and toxic potential of numerous toxins throughout the years and are more recently growing in popularity to assess the impacts of environmental pollutants. Hydra are an appropriate bioindicator species for use in environmental assessment owing to their easily measurable physical (morphology), biochemical (xenobiotic biotransformation; oxidative stress), behavioural (feeding) and reproductive (sexual and asexual) endpoints. Hydra also possess an unparalleled ability to regenerate, allowing the assessment of teratogenic compounds and the impact of contaminants on stem cells. Importantly, Hydra are ubiquitous throughout freshwater environments and relatively easy to culture making them appropriate for use in small scale bioassay systems. Hydra have been used to assess the environmental impacts of numerous environmental pollutants including metals, organic toxicants (including pharmaceuticals and endocrine disrupting compounds), nanomaterials and industrial and municipal effluents. They have been found to be among the most sensitive animals tested for metals and certain effluents, comparing favourably with more standardised toxicity tests. Despite their lack of use in formalised monitoring programmes, Hydra have been extensively used and are regarded as a model organism in aquatic toxicology.

  19. Photovoltaic tests and applications project

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The activities and accomplishments of the Photovoltaic Tests and Applications Project during the period April 1976 through June 1977 are summarized. Results of efforts to identify potential near-term photovoltaic applications and users are discussed, including the outcome of an extensive survey of Federal government agencies. The status of application experiments is presented. Various general engineering efforts are reported, including the design and construction of a photovoltaic Systems Test Facility. Efforts to develop a high efficiency 10 kVA self-commutated inverter and controller specifically designed for photovoltaic systems are also discussed. The results of a wide variety of activities in the area of photovoltaic measurements and standards are related. Documents generated by the Project during the reporting period are listed in an Appendix.

  20. Calculating Nozzle Side Loads using Acceleration Measurements of Test-Based Models

    NASA Technical Reports Server (NTRS)

    Brown, Andrew M.; Ruf, Joe

    2007-01-01

    As part of a NASA/MSFC research program to evaluate the effect of different nozzle contours on the well-known but poorly characterized "side load" phenomena, we attempt to back out the net force on a sub-scale nozzle during cold-flow testing using acceleration measurements. Because modeling the test facility dynamics is problematic, new techniques for creating a "pseudo-model" of the facility and nozzle directly from modal test results are applied. Extensive verification procedures were undertaken, resulting in a loading scale factor necessary for agreement between test and model based frequency response functions. Side loads are then obtained by applying a wide-band random load onto the system model, obtaining nozzle response PSD's, and iterating both the amplitude and frequency of the input until a good comparison of the response with the measured response PSD for a specific time point is obtained. The final calculated loading can be used to compare different nozzle profiles for assessment during rocket engine nozzle development and as a basis for accurate design of the nozzle and engine structure to withstand these loads. The techniques applied within this procedure have extensive applicability to timely and accurate characterization of all test fixtures used for modal test.A viewgraph presentation on a model-test based pseudo-model used to calculate side loads on rocket engine nozzles is included. The topics include: 1) Side Loads in Rocket Nozzles; 2) Present Side Loads Research at NASA/MSFC; 3) Structural Dynamic Model Generation; 4) Pseudo-Model Generation; 5) Implementation; 6) Calibration of Pseudo-Model Response; 7) Pseudo-Model Response Verification; 8) Inverse Force Determination; 9) Results; and 10) Recent Work.

  1. 75 FR 48728 - The Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-11

    ... Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the Office of... the information collection requirements contained in the Hydrostatic Testing provision of the Portable... 48729

  2. Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws.

    PubMed

    Lapsiwala, Samir B; Anderson, Paul A; Oza, Ashish; Resnick, Daniel K

    2006-03-01

    We performed a biomechanical comparison of several C1 to C2 fixation techniques including crossed laminar (intralaminar) screw fixation, anterior C1 to C2 transarticular screw fixation, C1 to 2 pedicle screw fixation, and posterior C1 to C2 transarticular screw fixation. Eight cadaveric cervical spines were tested intact and after dens fracture. Four different C1 to C2 screw fixation techniques were tested. Posterior transarticular and pedicle screw constructs were tested twice, once with supplemental sublaminar cables and once without cables. The specimens were tested in three modes of loading: flexion-extension, lateral bending, and axial rotation. All tests were performed in load and torque control. Pure bending moments of 2 nm were applied in flexion-extension and lateral bending, whereas a 1 nm moment was applied in axial rotation. Linear displacements were recorded from extensometers rigidly affixed to the C1 and C2 vertebrae. Linear displacements were reduced to angular displacements using trigonometry. Adding cable fixation results in a stiffer construct for posterior transarticular screws. The addition of cables did not affect the stiffness of C1 to C2 pedicle screw constructs. There were no significant differences in stiffness between anterior and posterior transarticular screw techniques, unless cable fixation was added to the posterior construct. All three posterior screw constructs with supplemental cable fixation provide equal stiffness with regard to flexion-extension and axial rotation. C1 lateral mass-C2 intralaminar screw fixation restored resistance to lateral bending but not to the same degree as the other screw fixation techniques. All four screw fixation techniques limit motion at the C1 to 2 articulation. The addition of cable fixation improves resistance to flexion and extension for posterior transarticular screw fixation.

  3. Reuse fo a Cold War Surveillance Drone to Flight Test a NASA Rocket Based Combined Cycle Engine

    NASA Technical Reports Server (NTRS)

    Brown, T. M.; Smith, Norm

    1999-01-01

    Plans for and early feasibility investigations into the modification of a Lockheed D21B drone to flight test the DRACO Rocket Based Combined Cycle (RBCC) engine are discussed. Modifications include the addition of oxidizer tanks, modern avionics systems, actuators, and a vehicle recovery system. Current study results indicate that the D21B is a suitable candidate for this application and will allow demonstrations of all DRACO engine operating modes at Mach numbers between 0.8 and 4.0. Higher Mach numbers may be achieved with more extensive modification. Possible project risks include low speed stability and control, and recovery techniques.

  4. Experimental study using Nearfield Acoustical Holography of sound transmission fuselage sidewall structures

    NASA Technical Reports Server (NTRS)

    Maynard, J. D.

    1983-01-01

    This project involves the development of the Nearfield Acoustic Holography (NAH) technique (in particular its extension from single frequency to wideband noise measurement) and its application in a detailed study of the noise radiation characteristics of several samples of aircraft sidewall panels. With the extensive amount of information provided by the NAH technique, the properties of the sound field radiated by the panels may be correlated with their structure, mounting, and excitation (single frequency or wideband, spatially correlated or uncorrelated, structure-borne). The work accomplished at the beginning of this grant period included: (1) Calibration of the 256 microphone array and test of its accuracy. (2) extension of the facility to permit measurements on wideband noise sources. The extensions incuded the addition of high-speed data acquisition hardware and an array processor, and the development of new software. (3) Installation of motion picture graphics for correlating panel motion with structure, mounting, radiation, etc. (4) Development of new holographic data processing techniques.

  5. Memory for Items and Relationships among Items Embedded in Realistic Scenes: Disproportionate Relational Memory Impairments in Amnesia

    PubMed Central

    Hannula, Deborah E.; Tranel, Daniel; Allen, John S.; Kirchhoff, Brenda A.; Nickel, Allison E.; Cohen, Neal J.

    2014-01-01

    Objective The objective of this study was to examine the dependence of item memory and relational memory on medial temporal lobe (MTL) structures. Patients with amnesia, who either had extensive MTL damage or damage that was relatively restricted to the hippocampus, were tested, as was a matched comparison group. Disproportionate relational memory impairments were predicted for both patient groups, and those with extensive MTL damage were also expected to have impaired item memory. Method Participants studied scenes, and were tested with interleaved two-alternative forced-choice probe trials. Probe trials were either presented immediately after the corresponding study trial (lag 1), five trials later (lag 5), or nine trials later (lag 9) and consisted of the studied scene along with a manipulated version of that scene in which one item was replaced with a different exemplar (item memory test) or was moved to a new location (relational memory test). Participants were to identify the exact match of the studied scene. Results As predicted, patients were disproportionately impaired on the test of relational memory. Item memory performance was marginally poorer among patients with extensive MTL damage, but both groups were impaired relative to matched comparison participants. Impaired performance was evident at all lags, including the shortest possible lag (lag 1). Conclusions The results are consistent with the proposed role of the hippocampus in relational memory binding and representation, even at short delays, and suggest that the hippocampus may also contribute to successful item memory when items are embedded in complex scenes. PMID:25068665

  6. Biomechanical Effects of Capsular Shift in the Treatment of Hip Microinstability: Creation and Testing of a Novel Hip Instability Model.

    PubMed

    Jackson, Timothy J; Peterson, Alexander B; Akeda, Masaki; Estess, Allyson; McGarry, Michelle H; Adamson, Gregory J; Lee, Thay Q

    2016-03-01

    A capsular shift procedure has been described for the treatment of hip instability; however, the biomechanical effects of such a shift are unknown. To create a cadaveric model of hip capsule laxity and evaluate the biomechanical effects of a capsular shift used to treat hip instability on this model. Controlled laboratory study. Eight cadaveric hips with an average age of 58.5 years were tested with a custom hip testing system in 6 conditions: intact, vented, instability, capsulotomy, side-to-side repair, and capsular shift. To create the hip model, the capsule was stretched in extension under 35 N·m of torque for 1 hour in neutral rotation. Measurements included internal and external rotation with 1.5 N·m of torque at 5 positions: 5° of extension and 0°, 15°, 30°, and 45° of flexion for each of the above conditions. The degree of maximum extension with 5 N·m of torque and the amount of femoral distraction with 40 N and 80 N of force were measured. Statistical analysis was performed by use of repeated-measures analysis of variance with Tukey post hoc analysis. The instability state significantly increased internal rotation at all flexion angles and increased distraction compared with the intact state. The capsulotomy condition resulted in significantly increased external rotation and internal rotation at all positions, increased distraction, and maximum extension compared with the intact state. The side-to-side repair condition restored internal rotation back to the instability state but not to the intact state at 5° of extension and 0° of flexion. The capsular shift state significantly decreased internal rotation compared with the instability state at 5° of extension and 0° and 15° of flexion. The capsular shift and side-to-side repair conditions had similar effects on external rotation at all flexion-extension positions. The capsular shift state decreased distraction and maximum extension compared with the instability state, but the side-to-side repair state did not. The hip capsular instability model was shown to have significantly greater total range of motion, external rotation, and extension compared with the intact condition. The greatest effects of capsular shift are seen with internal rotation, maximum extension, and distraction, with minimal effect on external rotation compared with the side-to side repair state. The biomechanical effects of the capsular shift procedure indicate that it can be used to treat hip capsular laxity by decreasing extension and distraction with minimal effect on external rotation. © 2015 The Author(s).

  7. A Study on the Effects of Sympathetic Skin Response Parameters in Diagnosis of Fibromyalgia Using Artificial Neural Networks.

    PubMed

    Ozkan, Ozhan; Yildiz, Murat; Arslan, Evren; Yildiz, Sedat; Bilgin, Suleyman; Akkus, Selami; Koyuncuoglu, Hasan R; Koklukaya, Etem

    2016-03-01

    Fibromyalgia syndrome (FMS), usually observed commonly in females over age 30, is a rheumatic disease accompanied by extensive chronic pain. In the diagnosis of the disease non-objective psychological tests and physiological tests and laboratory test results are evaluated and clinical experiences stand out. However, these tests are insufficient in differentiating FMS with similar diseases that demonstrate symptoms of extensive pain. Thus, objective tests that would help the diagnosis are needed. This study analyzes the effect of sympathetic skin response (SSR) parameters on the auxiliary tests used in FMS diagnosis, the laboratory tests and physiological tests. The study was conducted in Suleyman Demirel University, Faculty of Medicine, Physical Medicine and Rehabilitation Clinic in Turkey with 60 patients diagnosed with FMS for the first time and a control group of 30 healthy individuals. In the study all participants underwent laboratory tests (blood tests), certain physiological tests (pulsation, skin temperature, respiration) and SSR measurements. The test data and SSR parameters obtained were classified using artificial neural network (ANN). Finally, in the ANN framework, where only laboratory and physiological test results were used as input, a simulation result of 96.51 % was obtained, which demonstrated diagnostic accuracy. This data, with the addition of SSR parameter values obtained increased to 97.67 %. This result including SSR parameters - meaning a higher diagnostic accuracy - demonstrated that SSR could be a new auxillary diagnostic method that could be used in the diagnosis of FMS.

  8. Application of damage tolerance methodology in certification of the Piaggio P-180 Avanti

    NASA Technical Reports Server (NTRS)

    Johnson, Jerry

    1992-01-01

    The Piaggio P-180 Avanti, a twin pusher-prop engine nine-passenger business aircraft was certified in 1990, to the requirements of FAR Part 23 and Associated Special Conditions for Composite Structure. Certification included the application of a damage tolerant methodology to the design of the composite forward wing and empennage (vertical fin, horizontal stabilizer, tailcone, and rudder) structure. This methodology included an extensive analytical evaluation coupled with sub-component and full-scale testing of the structure. The work from the Damage Tolerance Analysis Assessment was incorporated into the full-scale testing. Damage representing hazards such as dropped tools, ground equipment, handling, and runway debris, was applied to the test articles. Additional substantiation included allowing manufacturing discrepancies to exist unrepaired on the full-scale articles and simulated bondline failures in critical elements. The importance of full-scale testing in the critical environmental conditions and the application of critical damage are addressed. The implication of damage tolerance on static and fatigue testing is discussed. Good correlation between finite element solutions and experimental test data was observed.

  9. Deployment/retraction ground testing of a large flexible solar array

    NASA Technical Reports Server (NTRS)

    Chung, D. T.

    1982-01-01

    The simulated zero-gravity ground testing of the flexible fold-up solar array consisting of eighty-four full-size panels (.368 m x .4 m each) is addressed. Automatic, hands-off extension, retraction, and lockup operations are included. Three methods of ground testing were investigated: (1) vertical testing; (2) horizontal testing, using an overhead water trough to support the panels; and (3) horizontal testing, using an overhead track in conjunction with a counterweight system to support the panels. Method 3 was selected as baseline. The wing/assembly vertical support structure, the five-tier overhead track, and the mast-element support track comprise the test structure. The flexible solar array wing assembly was successfully extended and retracted numerous times under simulated zero-gravity conditions.

  10. NASA/MSFC's Calculation for Test Case 1a of ATAC-FSDC Workshop on After-body and Nozzle Flows

    NASA Technical Reports Server (NTRS)

    Ruf, Joseph H.

    2006-01-01

    Mr. Ruf of NASA/MSFC executed the CHEM computational fluid dynamics (CFD) code to provide a prediction of the test case 1 a for the ATAC-FSDC Workshop on After-body and Nozzle Flows. CHEM is used extensively at MSFC for a wide variety of fluid dynamic problems. These problems include; injector element flows, nozzle flows, feed line flows, turbomachinery flows, solid rocket motor internal flows, plume vehicle flow interactions, etc.

  11. Development of a CCD based solar speckle imaging system

    NASA Astrophysics Data System (ADS)

    Nisenson, Peter; Stachnik, Robert V.; Noyes, Robert W.

    1986-02-01

    A program to develop software and hardware for the purpose of obtaining high angular resolution images of the solar surface is described. The program included the procurement of a Charge Coupled Devices imaging system; an extensive laboratory and remote site testing of the camera system; the development of a software package for speckle image reconstruction which was eventually installed and tested at the Sacramento Peak Observatory; and experiments of the CCD system (coupled to an image intensifier) for low light level, narrow spectral band solar imaging.

  12. Subsynchronous instability of a geared centrifugal compressor of overhung design

    NASA Technical Reports Server (NTRS)

    Hudson, J. H.; Wittman, L. J.

    1980-01-01

    The original design analysis and shop test data are presented for a three stage (poster) air compressor with impellers mounted on the extensions of a twin pinion gear, and driven by an 8000 hp synchronous motor. Also included are field test data, subsequent rotor dynamics analysis, modifications, and final rotor behavior. A subsynchronous instability existed on a geared, overhung rotor. State-of-the-art rotor dynamics analysis techniques provided a reasonable analytical model of the rotor. A bearing modification arrived at analytically eliminated the instability.

  13. Preliminary design and development of a reflectance spectrometer instrument

    NASA Technical Reports Server (NTRS)

    Mccord, T. B.

    1979-01-01

    An improved design for the reflectance spectrometer is described to be used on various terrestrial body missions. These improvements were made on the original Lunar Polar Orbiter design. These include a larger entrance mirror, rectangular aperture, multiple optical beams, spatial resolution, and a bandwidth extension to 5 microns. In addition, detailed electronic designs were produced for a charge amplifier and an amplifier/demodulator/integrator. Design of a microprocessor driven test system was begun. Laboratory tests were performed on a tuning fork chopper.

  14. Experimental Investigation of Fibre Reinforced Composite Materials Under Impact Load

    NASA Astrophysics Data System (ADS)

    Koppula, Sravani; Kaviti, Ajay kumar; Namala, Kiran kumar

    2018-03-01

    Composite materials are extensively used in various engineering applications. They have very high flexibility design which allows prescribe tailoring of material properties by lamination of composite fibres with reinforcement of resin to it. Complex failure condition prevail in the composite materials under the action of impact loads, major modes of failure in composite may include matrix cracking, fibre matrix, fibre breakage, de-bonding or de- lamination between composite plies. This paper describes the mechanical properties of glass fibre reinforced composite material under impact loading conditions through experimental setup. Experimental tests are performed according to ASTM standards using impact testing machines like Charpy test, computerized universal testing machine.

  15. A validation of LTRAN2 with high frequency extensions by comparisons with experimental measurements of unsteady transonic flows

    NASA Technical Reports Server (NTRS)

    Hessenius, K. A.; Goorjian, P. M.

    1981-01-01

    A high frequency extension of the unsteady, transonic code LTRAN2 was created and is evaluated by comparisons with experimental results. The experimental test case is a NACA 64A010 airfoil in pitching motion at a Mach number of 0.8 over a range of reduced frequencies. Comparisons indicate that the modified code is an improvement of the original LTRAN2 and provides closer agreement with experimental lift and moment coefficients. A discussion of the code modifications, which involve the addition of high frequency terms of the boundary conditions of the numerical algorithm, is included.

  16. Scan-Based Implementation of JPEG 2000 Extensions

    NASA Technical Reports Server (NTRS)

    Rountree, Janet C.; Webb, Brian N.; Flohr, Thomas J.; Marcellin, Michael W.

    2001-01-01

    JPEG 2000 Part 2 (Extensions) contains a number of technologies that are of potential interest in remote sensing applications. These include arbitrary wavelet transforms, techniques to limit boundary artifacts in tiles, multiple component transforms, and trellis-coded quantization (TCQ). We are investigating the addition of these features to the low-memory (scan-based) implementation of JPEG 2000 Part 1. A scan-based implementation of TCQ has been realized and tested, with a very small performance loss as compared with the full image (frame-based) version. A proposed amendment to JPEG 2000 Part 2 will effect the syntax changes required to make scan-based TCQ compatible with the standard.

  17. WRAP-RIB antenna technology development

    NASA Technical Reports Server (NTRS)

    Freeland, R. E.; Garcia, N. F.; Iwamoto, H.

    1985-01-01

    The wrap-rib deployable antenna concept development is based on a combination of hardware development and testing along with extensive supporting analysis. The proof-of-concept hardware models are large in size so they will address the same basic problems associated with the design fabrication, assembly and test as the full-scale systems which were selected to be 100 meters at the beginning of the program. The hardware evaluation program consists of functional performance tests, design verification tests and analytical model verification tests. Functional testing consists of kinematic deployment, mesh management and verification of mechanical packaging efficiencies. Design verification consists of rib contour precision measurement, rib cross-section variation evaluation, rib materials characterizations and manufacturing imperfections assessment. Analytical model verification and refinement include mesh stiffness measurement, rib static and dynamic testing, mass measurement, and rib cross-section characterization. This concept was considered for a number of potential applications that include mobile communications, VLBI, and aircraft surveillance. In fact, baseline system configurations were developed by JPL, using the appropriate wrap-rib antenna, for all three classes of applications.

  18. An out-of-core thermionic-converter system for nuclear space power

    NASA Technical Reports Server (NTRS)

    Breitwieser, R.

    1972-01-01

    Design of the nuclear thermionic space power system, 40 50 70 Kw(e) power range, are given. The design configuration (1) meets the constraints of readily available launch vehicles; (2) allows for off-design operation including startup, shutdown, and possible emergency conditions; (3) provides tolerance of failure by extensive use of modular, redundant elements; (4) incorporates and uses heat pipes in a fashion that reduces the need for extensive in-pile testing of system components; and (5) uses thermionic converters, nuclear fuel elements, and heat transfer devices in a geometrical form adapted from existing incore thermionic system designs. Designs and in some cases performance data for elements and groups of the elements of the system are included. Benefits of the highly modular system approach to reliability, safety, economy of development, and flexibility are discussed.

  19. Laboratory or Field Tests for Evaluating Firefighters' Work Capacity?

    PubMed Central

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = −0.81) and barbell shoulder press (rs = −0.77), for Pulling: IE shoulder extension (rs = −0.82) and bench press (rs = −0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = −0.83) and bench press (rs = −0.82), and for the Terrain work task: IE trunk flexion (rs = −0.58) and upright barbell row (rs = −0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity. PMID:24614596

  20. Assessment of Hybrid High-Order methods on curved meshes and comparison with discontinuous Galerkin methods

    NASA Astrophysics Data System (ADS)

    Botti, Lorenzo; Di Pietro, Daniele A.

    2018-10-01

    We propose and validate a novel extension of Hybrid High-Order (HHO) methods to meshes featuring curved elements. HHO methods are based on discrete unknowns that are broken polynomials on the mesh and its skeleton. We propose here the use of physical frame polynomials over mesh elements and reference frame polynomials over mesh faces. With this choice, the degree of face unknowns must be suitably selected in order to recover on curved meshes the same convergence rates as on straight meshes. We provide an estimate of the optimal face polynomial degree depending on the element polynomial degree and on the so-called effective mapping order. The estimate is numerically validated through specifically crafted numerical tests. All test cases are conducted considering two- and three-dimensional pure diffusion problems, and include comparisons with discontinuous Galerkin discretizations. The extension to agglomerated meshes with curved boundaries is also considered.

  1. Standard specification for light ladders

    NASA Astrophysics Data System (ADS)

    1980-11-01

    Requirements are given for the construction, inspection, and testing of single ladders, extension ladders, step-ladders, extending step-ladders, trestle ladders, extending trestle ladders, and special purpose ladders. The composition of the aluminum alloys, and of the steels and glass fiber reinforced polyester components coming into contact with the aluminum are included. Coatings used to provide corrosion resistance are also specified.

  2. Classroom Experiences in an Engineering Design Graphics Course with a CAD/CAM Extension.

    ERIC Educational Resources Information Center

    Barr, Ronald E.; Juricic, Davor

    1997-01-01

    Reports on the development of a new CAD/CAM laboratory experience for an Engineering Design Graphics (EDG) course. The EDG curriculum included freehand sketching, introduction to Computer-Aided Design and Drafting (CADD), and emphasized 3-D solid modeling. Reviews the project and reports on the testing of the new laboratory components which were…

  3. Results from the Operational Testing of the General Electric Smart Grid Capable Electric Vehicle Supply Equipment (EVSE)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlson, Richard Barney; Scoffield, Don; Bennett, Brion

    2013-12-01

    The Idaho National Laboratory conducted testing and analysis of the General Electric (GE) smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from GE for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the GE smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionalitymore » testing, abnormal conditions testing, and charging of a plug-in vehicle.« less

  4. First Human Testing of the Orion Atmosphere Revitalization Technology

    NASA Technical Reports Server (NTRS)

    Lin, Amy; Sweterlitsch, Jeffrey

    2009-01-01

    An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). In two previous years at this conference, reports were presented on extensive Johnson Space Center (JSC) testing of the technology in a representative environment with simulated human metabolic loads. The next step in developmental testing at JSC was to replace the simulated humans with real humans; this testing was conducted in the spring of 2008. This first instance of human testing of a new Orion ARS technology included several cases in a sealed Orion-equivalent free volume and three cases using emergency breathing masks connected directly to the ARS loop. Significant test results presented in this paper include comparisons between the standard metabolic rates for CO2 and water vapor production published in Orion requirements documents and real-world rate ranges observed with human test subjects. Also included are qualitative assessments of process flow rate and closed-loop pressure-cycling tolerability while using the emergency masks. Recommendations for modifications to the Orion ARS design and operation, based on the test results, conclude the paper.

  5. First Human Testing of the Orion Atmosphere Revitalization Technology

    NASA Technical Reports Server (NTRS)

    Lin, Amy; Sweterlitsch, Jeffrey

    2008-01-01

    An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). In two previous years at this conference, reports were presented on extensive Johnson Space Center (JSC) testing of the technology in a representative environment with simulated human metabolic loads. The next step in developmental testing at JSC was to replace the simulated humans with real humans; this testing was conducted in the spring of 2008. This first instance of human testing of a new Orion ARS technology included several cases in a sealed Orione-quivalent free volume and three cases using emergency breathing masks connected directly to the ARS loop. Significant test results presented in this paper include comparisons between the standard metabolic rates for CO2 and water vapor production published in Orion requirements documents and real-world rate ranges observed with human test subjects. Also included are qualitative assessments of process flow rate and closed-loop pressure-cycling tolerability while using the emergency masks. Recommendations for modifications to the Orion ARS design and operation, based on the test results, conclude the paper.

  6. Neurodynamic responses to the femoral slump test in patients with anterior knee pain syndrome.

    PubMed

    Lin, Pei-Ling; Shih, Yi-Fen; Chen, Wen-Yin; Ma, Hsiao-Li

    2014-05-01

    Matched-control, cross-sectional study. The purpose of this study was to compare the responses to the femoral slump test (FST), including the change in hip range of motion and level of discomfort, between subjects with and without anterior knee pain. Anterior knee pain syndrome is a common problem among adults. The FST is the neurodynamic test used to assess the mechanosensitivity of the femoral component of the nervous system. However, as of yet, there is no literature discussing the use of the FST in patients with anterior knee pain. Thirty patients with anterior knee pain and 30 control participants, matched by gender, age, and dominant leg, were recruited. The subjects received the FST, during which the hip extension angle and the location and intensity of pain/discomfort were recorded. Reproduction of symptoms that were alleviated by neck extension was interpreted as a positive test. Differences in hip extension angle and pain intensity between groups were examined using a 2-way, repeated-measures analysis of variance and a Kruskal-Wallis analysis. The level of significance was set at α = .05. Subjects with anterior knee pain had a smaller hip extension angle than that of controls (-3.6° ± 5.3° versus 0.6° ± 6.1°; mean difference, 4.2°; 95% confidence interval [CI]: 1.24°, 7.15°; P = .006). Eight patients with anterior knee pain showed a positive FST, and those with a positive FST had a smaller hip extension angle (-5.7° ± 4.5°) than that of controls (mean difference, 6.3°; 95% CI: 0.8°, 11.8°; P = .007). There was no difference in the hip extension angle between the positive and negative FST groups (mean difference, 2.9°; 95% CI: -8.5°, 2.0°) or between the negative FST and control groups (mean difference, 3.4°; 95% CI: -0.4°, 7.3°). Results of this study suggest that altered mechanosensitivity of the femoral nerve occurred in the patients with anterior knee pain who presented with a positive FST. The role of increased mechanosensitivity in the development and management of anterior knee pain should be investigated in the future.

  7. Extensions to decision curve analysis, a novel method for evaluating diagnostic tests, prediction models and molecular markers

    PubMed Central

    Vickers, Andrew J; Cronin, Angel M; Elkin, Elena B; Gonen, Mithat

    2008-01-01

    Background Decision curve analysis is a novel method for evaluating diagnostic tests, prediction models and molecular markers. It combines the mathematical simplicity of accuracy measures, such as sensitivity and specificity, with the clinical applicability of decision analytic approaches. Most critically, decision curve analysis can be applied directly to a data set, and does not require the sort of external data on costs, benefits and preferences typically required by traditional decision analytic techniques. Methods In this paper we present several extensions to decision curve analysis including correction for overfit, confidence intervals, application to censored data (including competing risk) and calculation of decision curves directly from predicted probabilities. All of these extensions are based on straightforward methods that have previously been described in the literature for application to analogous statistical techniques. Results Simulation studies showed that repeated 10-fold crossvalidation provided the best method for correcting a decision curve for overfit. The method for applying decision curves to censored data had little bias and coverage was excellent; for competing risk, decision curves were appropriately affected by the incidence of the competing risk and the association between the competing risk and the predictor of interest. Calculation of decision curves directly from predicted probabilities led to a smoothing of the decision curve. Conclusion Decision curve analysis can be easily extended to many of the applications common to performance measures for prediction models. Software to implement decision curve analysis is provided. PMID:19036144

  8. Extensions to decision curve analysis, a novel method for evaluating diagnostic tests, prediction models and molecular markers.

    PubMed

    Vickers, Andrew J; Cronin, Angel M; Elkin, Elena B; Gonen, Mithat

    2008-11-26

    Decision curve analysis is a novel method for evaluating diagnostic tests, prediction models and molecular markers. It combines the mathematical simplicity of accuracy measures, such as sensitivity and specificity, with the clinical applicability of decision analytic approaches. Most critically, decision curve analysis can be applied directly to a data set, and does not require the sort of external data on costs, benefits and preferences typically required by traditional decision analytic techniques. In this paper we present several extensions to decision curve analysis including correction for overfit, confidence intervals, application to censored data (including competing risk) and calculation of decision curves directly from predicted probabilities. All of these extensions are based on straightforward methods that have previously been described in the literature for application to analogous statistical techniques. Simulation studies showed that repeated 10-fold crossvalidation provided the best method for correcting a decision curve for overfit. The method for applying decision curves to censored data had little bias and coverage was excellent; for competing risk, decision curves were appropriately affected by the incidence of the competing risk and the association between the competing risk and the predictor of interest. Calculation of decision curves directly from predicted probabilities led to a smoothing of the decision curve. Decision curve analysis can be easily extended to many of the applications common to performance measures for prediction models. Software to implement decision curve analysis is provided.

  9. SLHAplus: A library for implementing extensions of the standard model

    NASA Astrophysics Data System (ADS)

    Bélanger, G.; Christensen, Neil D.; Pukhov, A.; Semenov, A.

    2011-03-01

    We provide a library to facilitate the implementation of new models in codes such as matrix element and event generators or codes for computing dark matter observables. The library contains an SLHA reader routine as well as diagonalisation routines. This library is available in CalcHEP and micrOMEGAs. The implementation of models based on this library is supported by LanHEP and FeynRules. Program summaryProgram title: SLHAplus_1.3 Catalogue identifier: AEHX_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEHX_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 6283 No. of bytes in distributed program, including test data, etc.: 52 119 Distribution format: tar.gz Programming language: C Computer: IBM PC, MAC Operating system: UNIX (Linux, Darwin, Cygwin) RAM: 2000 MB Classification: 11.1 Nature of problem: Implementation of extensions of the standard model in matrix element and event generators and codes for dark matter observables. Solution method: For generic extensions of the standard model we provide routines for reading files that adopt the standard format of the SUSY Les Houches Accord (SLHA) file. The procedure has been generalized to take into account an arbitrary number of blocks so that the reader can be used in generic models including non-supersymmetric ones. The library also contains routines to diagonalize real and complex mass matrices with either unitary or bi-unitary transformations as well as routines for evaluating the running strong coupling constant, running quark masses and effective quark masses. Running time: 0.001 sec

  10. Fun During Knee Rehabilitation: Feasibility and Acceptability Testing of a New Android-Based Training Device.

    PubMed

    Weber-Spickschen, Thomas Sanjay; Colcuc, Christian; Hanke, Alexander; Clausen, Jan-Dierk; James, Paul Abraham; Horstmann, Hauke

    2017-01-01

    The initial goals of rehabilitation after knee injuries and operations are to achieve full knee extension and to activate quadriceps muscle. In addition to regular physiotherapy, an android-based knee training device is designed to help patients achieve these goals and improve compliance in the early rehabilitation period. This knee training device combines fun in a computer game with muscular training or rehabilitation. Our aim was to test the feasibility and acceptability of this new device. 50 volunteered subjects enrolled to test out the computer game aided device. The first game was the high-striker game, which recorded maximum knee extension power. The second game involved controlling quadriceps muscular power to simulate flying an aeroplane in order to record accuracy of muscle activation. The subjects evaluated this game by completing a simple questionnaire. No technical problem was encountered during the usage of this device. No subjects complained of any discomfort after using this device. Measurements including maximum knee extension power, knee muscle activation and control were recorded successfully. Subjects rated their experience with the device as either excellent or very good and agreed that the device can motivate and monitor the progress of knee rehabilitation training. To the best of our knowledge, this is the first android-based tool available to fast track knee rehabilitation training. All subjects gave very positive feedback to this computer game aided knee device.

  11. Using GIS to analyze animal movements in the marine environment

    USGS Publications Warehouse

    Hooge, Philip N.; Eichenlaub, William M.; Solomon, Elizabeth K.; Kruse, Gordon H.; Bez, Nicolas; Booth, Anthony; Dorn, Martin W.; Hills, Susan; Lipcius, Romuald N.; Pelletier, Dominique; Roy, Claude; Smith, Stephen J.; Witherell, David B.

    2001-01-01

    Advanced methods for analyzing animal movements have been little used in the aquatic research environment compared to the terrestrial. In addition, despite obvious advantages of integrating geographic information systems (GIS) with spatial studies of animal movement behavior, movement analysis tools have not been integrated into GIS for either aquatic or terrestrial environments. We therefore developed software that integrates one of the most commonly used GIS programs (ArcView®) with a large collection of animal movement analysis tools. This application, the Animal Movement Analyst Extension (AMAE), can be loaded as an extension to ArcView® under multiple operating system platforms (PC, Unix, and Mac OS). It contains more than 50 functions, including parametric and nonparametric home range analyses, random walk models, habitat analyses, point and circular statistics, tests of complete spatial randomness, tests for autocorrelation and sample size, point and line manipulation tools, and animation tools. This paper describes the use of these functions in analyzing animal location data; some limited examples are drawn from a sonic-tracking study of Pacific halibut (Hippoglossus stenolepis) in Glacier Bay, Alaska. The extension is available on the Internet at www.absc.usgs.gov/glba/gistools/index.htm.

  12. Heavy-section steel technology and irradiation programs-retrospective and prospective views

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nanstad, Randy K; Bass, Bennett Richard; Rosseel, Thomas M

    In 1965, the Atomic Energy Commission (AEC), at the advice of the Advisory Committee on Reactor Safeguards (ACRS), initiated the process that resulted in the establishment of the Heavy Section Steel Technology (HSST) Program at Oak Ridge National Laboratory (ORNL). Dr. Spencer H. Bush of Battelle Northwest Laboratory, the man being honored by this symposium, representing the ACRS, was one of the Staff Advisors for the program and helped to guide its technical direction. In 1989, the Heavy-Section Steel Irradiation (HSSI) Program, formerly the HSST task on irradiation effects, was formed as a separate program, and this year the HSST/HSSImore » Programs, sponsored by the U.S. Nuclear Regulatory Commission (USNRC), celebrate 40 years of continuous research oriented toward the safety of light-water nuclear reactor pressure vessels. This paper presents a summary of results from those programs with a view to future activities. The HSST Program was established in 1967 and initially included extensive investigations of heavy-section low-alloy steel plates, forgings, and welds, including metallurgical studies, mechanical properties, fracture toughness (quasi-static and dynamic), fatigue crack-growth, and crack arrest toughness. Also included were irradiation effects studies, thermal shock analyses, testing of thick-section tensile and fracture specimens, and non-destructive testing. In the subsequent decades, the HSST Program conducted extensive large-scale experiments with intermediate-size vessels (with varying size flaws) pressurized to failure, similar experiments under conditions of thermal shock and even pressurized thermal shock (PTS), wide-plate crack arrest tests, and biaxial tests with cruciform-shaped specimens. Extensive analytical and numerical studies accompanied these experiments, including the development of computer codes such as the recent Fracture Analysis of Vessels Oak Ridge (FAVOR) code currently being used for PTS evaluations. In the absence of radiation damage to the RPV, fracture of the vessel is improbable. However, exposure to high energy neutrons can result in embrittlement of radiation-sensitive RPV materials. The HSSI Program has conducted a series of experiments to assess the effects of neutron irradiation on RPV material behavior, especially fracture toughness. These studies have included RPV plates and welds, varying chemical compositions, and fracture toughness specimens up to 4 in. thickness. The results of these investigations, in conjunction with results from commercial reactor surveillance programs, are used to develop a methodology for the prediction of radiation effects on RPV materials. Results from the HSST and HSSI Program are used by the USNRC in the evaluation of RPV integrity and regulation of overall nuclear plant safety.« less

  13. Enhancing Brain Lesions during Acute Optic Neuritis and/or Longitudinally Extensive Transverse Myelitis May Portend a Higher Relapse Rate in Neuromyelitis Optica Spectrum Disorders.

    PubMed

    Orman, G; Wang, K Y; Pekcevik, Y; Thompson, C B; Mealy, M; Levy, M; Izbudak, I

    2017-05-01

    Neuromyelitis optica spectrum disorders are inflammatory demyelinating disorders with optic neuritis and/or longitudinally extensive transverse myelitis episodes. We now know that neuromyelitis optica spectrum disorders are associated with antibodies to aquaporin-4, which are highly concentrated on astrocytic end-feet at the blood-brain barrier. Immune-mediated disruption of the blood-brain barrier may manifest as contrast enhancement on brain MR imaging. We aimed to delineate the extent and frequency of contrast enhancement on brain MR imaging within 1 month of optic neuritis and/or longitudinally extensive transverse myelitis attacks and to correlate contrast enhancement with outcome measures. Brain MRIs of patients with neuromyelitis optica spectrum disorders were evaluated for patterns of contrast enhancement (periependymal, cloudlike, leptomeningeal, and so forth). The Fisher exact test was used to evaluate differences between the proportion of contrast enhancement in patients who were seropositive and seronegative for aquaporin-4 antibodies. The Mann-Whitney test was used to compare the annualized relapse rate and disease duration between patients with and without contrast enhancement and with and without seropositivity. Brain MRIs of 77 patients were evaluated; 59 patients (10 males, 49 females) were scanned within 1 month of optic neuritis and/or longitudinally extensive transverse myelitis attacks and were included in the analysis. Forty-eight patients were seropositive, 9 were seronegative, and 2 were not tested for aquaporin-4 antibodies. Having brain contrast enhancement of any type during an acute attack was significantly associated with higher annualized relapse rates ( P = .03) and marginally associated with shorter disease duration ( P = .05). Having periependymal contrast enhancement was significantly associated with higher annualized relapse rates ( P = .03). Brain MRIs of patients with neuromyelitis optica spectrum disorders with contrast enhancement during an acute relapse of optic neuritis and/or longitudinally extensive transverse myelitis are associated with increased annual relapse rates. © 2017 by American Journal of Neuroradiology.

  14. Space shuttle phase B wind tunnel model and test information. Volume 2: Orbiter configuration

    NASA Technical Reports Server (NTRS)

    Glynn, J. L.; Poucher, D. E.

    1988-01-01

    Archived wind tunnel test data are available for flyback booster or other alternative recoverable configurations as well as reusable orbiters studied during initial development (Phase B) of the Space Shuttle. Considerable wind tunnel data was acquired by the competing contractors and the NASA centers for an extensive variety of configurations with an array of wing and body planforms. All contractor and NASA wind tunnel test data acquired in the Phase B development have been compiled into a data base and are available for applying to current winged flyback or recoverable booster aerodynamic studies. The Space Shuttle Phase B Wind Tunnel Data Base is structured by vehicle component and configuration type. Basic components include the booster, the orbiter, and the launch vehicle. Booster configuration types include straight and delta wings, canard, cylindrical, retro-glide and twin body. Orbiter configuration types include straight and delta wings, lifting body, drop tanks, and double delta wings. Launch configuration types include booster and orbiter components in various stacked and tandem combinations.

  15. Relationships of Functional Tests Following ACL Reconstruction: Exploratory Factor Analyses of the Lower Extremity Assessment Protocol.

    PubMed

    DiFabio, Melissa; Slater, Lindsay V; Norte, Grant; Goetschius, John; Hart, Joseph M; Hertel, Jay

    2018-03-01

    After ACL reconstruction (ACLR), deficits are often assessed using a variety of functional tests, which can be time consuming. It is unknown whether these tests provide redundant or unique information. To explore relationships between components of a battery of functional tests, the Lower Extremity Assessment Protocol (LEAP) was created to aid in developing the most informative, concise battery of tests for evaluating ACLR patients. Descriptive, cross-sectional. Laboratory. 76 ACLR patients (6.86±3.07 months postoperative) and 54 healthy participants. Isokinetic knee flexion and extension at 90 and 180 degrees/second, maximal voluntary isometric contraction for knee extension and flexion, single leg balance, 4 hopping tasks (single, triple, crossover, and 6-meter timed hop), and a bilateral drop vertical jump that was scored with the Landing Error Scoring System (LESS). Peak torque, average torque, average power, total work, fatigue indices, center of pressure area and velocity, hop distance and time, and LESS score. A series of factor analyses were conducted to assess grouping of functional tests on the LEAP for each limb in the ACLR and healthy groups and limb symmetry indices (LSI) for both groups. Correlations were run between measures that loaded on retained factors. Isokinetic and isometric strength tests for knee flexion and extension, hopping, balance, and fatigue index were identified as unique factors for all limbs. The LESS score loaded with various factors across the different limbs. The healthy group LSI analysis produced more factors than the ACLR LSI analysis. Individual measures within each factor had moderate to strong correlations. Isokinetic and isometric strength, hopping, balance, and fatigue index provided unique information. Within each category of measures, not all tests may need to be included for a comprehensive functional assessment of ACLR patients due to the high amount of shared variance between them.

  16. Genetic Testing in Clinical Settings.

    PubMed

    Franceschini, Nora; Frick, Amber; Kopp, Jeffrey B

    2018-04-11

    Genetic testing is used for screening, diagnosis, and prognosis of diseases consistent with a genetic cause and to guide drug therapy to improve drug efficacy and avoid adverse effects (pharmacogenomics). This In Practice review aims to inform about DNA-related genetic test availability, interpretation, and recommended clinical actions based on results using evidence from clinical guidelines, when available. We discuss challenges that limit the widespread use of genetic information in the clinical care setting, including a small number of actionable genetic variants with strong evidence of clinical validity and utility, and the need for improving the health literacy of health care providers and the public, including for direct-to-consumer tests. Ethical, legal, and social issues and incidental findings also need to be addressed. Because our understanding of genetic factors associated with disease and drug response is rapidly increasing and new genetic tests are being developed that could be adopted by clinicians in the short term, we also provide extensive resources for information and education on genetic testing. Copyright © 2018 National Kidney Foundation, Inc. All rights reserved.

  17. The use of real-time, hardware-in-the-loop simulation in the design and development of the new Hughes HS601 spacecraft attitude control system

    NASA Technical Reports Server (NTRS)

    Slafer, Loren I.

    1989-01-01

    Realtime simulation and hardware-in-the-loop testing is being used extensively in all phases of the design, development, and testing of the attitude control system (ACS) for the new Hughes HS601 satellite bus. Realtime, hardware-in-the-loop simulation, integrated with traditional analysis and pure simulation activities is shown to provide a highly efficient and productive overall development program. Implementation of high fidelity simulations of the satellite dynamics and control system algorithms, capable of real-time execution (using applied Dynamics International's System 100), provides a tool which is capable of being integrated with the critical flight microprocessor to create a mixed simulation test (MST). The MST creates a highly accurate, detailed simulated on-orbit test environment, capable of open and closed loop ACS testing, in which the ACS design can be validated. The MST is shown to provide a valuable extension of traditional test methods. A description of the MST configuration is presented, including the spacecraft dynamics simulation model, sensor and actuator emulators, and the test support system. Overall system performance parameters are presented. MST applications are discussed; supporting ACS design, developing on-orbit system performance predictions, flight software development and qualification testing (augmenting the traditional software-based testing), mission planning, and a cost-effective subsystem-level acceptance test. The MST is shown to provide an ideal tool in which the ACS designer can fly the spacecraft on the ground.

  18. Bringing the DuPont Profitability Model to Extension

    ERIC Educational Resources Information Center

    Roucan-Kane, Maud; Wolfskill, L. A.; Boehlje, Michael D.; Gray, Allan W.

    2013-01-01

    This article discusses a financial training program used by Deere and Company for almost 10 years. The objective is to describe the program and to discuss a pre-test/post-test methodology to test the effectiveness of a program for possible duplication by Extension. Results show that participants significantly improved from the pre-test to the…

  19. Polymer matrix and graphite fiber interface study

    NASA Technical Reports Server (NTRS)

    Adams, D. F.; Zimmerman, R. S.; Odom, E. M.

    1985-01-01

    Hercules AS4 graphite fiber, unsized, or with EPON 828, PVA, or polysulfone sizing, was combined with three different polymer matrices. These included Hercules 3501-6 epoxy, Hercules 4001 bismaleimide, and Hexcel F155 rubber toughened epoxy. Unidirectional composites in all twelve combinations were fabricated and tested in transverse tension and axial compression. Quasi-isotropic laminates were tested in axial tension and compression, flexure, interlaminar shear, and tensile impact. All tests were conducted at both room temperature, dry and elevated temperature, and wet conditions. Single fiber pullout testing was also performed. Extensive scanning electron microphotographs of fracture surfaces are included, along with photographs of single fiber pullout failures. Analytical/experimental correlations are presented, based on the results of a finite element micromechanics analysis. Correlations between matrix type, fiber sizing, hygrothermal environment, and loading mode are presented. Results indicate that the various composite properties were only moderately influenced by the fiber sizings utilized.

  20. Verification study of an emerging fire suppression system

    DOE PAGES

    Cournoyer, Michael E.; Waked, R. Ryan; Granzow, Howard N.; ...

    2016-01-01

    Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Moreover, plutonium gloveboxes present harsh environmental conditions for polymer materials; these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. Several studies have been conducted to determine the robustness of selfcontained fire extinguishers in plutonium gloveboxes in a nuclear facility, verification tests must be performed. These tests include activation and mass loss calorimeter tests. In addition, compatibility issues with chemical components of the self-contained fire extinguishers need to be addressed. Our study presents activation andmore » mass loss calorimeter test results. After extensive studies, no critical areas of concern have been identified for the plutonium glovebox application of Fire Foe™, except for glovebox operations that use large quantities of bulk plutonium or uranium metal such as metal casting and pyro-chemistry operations.« less

  1. Advanced air revitalization system modeling and testing

    NASA Technical Reports Server (NTRS)

    Dall-Baumann, Liese; Jeng, Frank; Christian, Steve; Edeer, Marybeth; Lin, Chin

    1990-01-01

    To support manned lunar and Martian exploration, an extensive evaluation of air revitalization subsystems (ARS) is being conducted. The major operations under study include carbon dioxide removal and reduction; oxygen and nitrogen production, storage, and distribution; humidity and temperature control; and trace contaminant control. A comprehensive analysis program based on a generalized block flow model was developed to facilitate the evaluation of various processes and their interaction. ASPEN PLUS was used in modelling carbon dioxide removal and reduction. Several life support test stands were developed to test new and existing technologies for their potential applicability in space. The goal was to identify processes which use compact, lightweight equipment and maximize the recovery of oxygen and water. The carbon dioxide removal test stands include solid amine/vacuum desorption (SAVD), regenerative silver oxide chemisorption, and electrochemical carbon dioxide concentration (EDC). Membrane-based carbon dioxide removal and humidity control, catalytic reduction of carbon dioxide, and catalytic oxidation of trace contaminants were also investigated.

  2. Verification study of an emerging fire suppression system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cournoyer, Michael E.; Waked, R. Ryan; Granzow, Howard N.

    Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Moreover, plutonium gloveboxes present harsh environmental conditions for polymer materials; these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. Several studies have been conducted to determine the robustness of selfcontained fire extinguishers in plutonium gloveboxes in a nuclear facility, verification tests must be performed. These tests include activation and mass loss calorimeter tests. In addition, compatibility issues with chemical components of the self-contained fire extinguishers need to be addressed. Our study presents activation andmore » mass loss calorimeter test results. After extensive studies, no critical areas of concern have been identified for the plutonium glovebox application of Fire Foe™, except for glovebox operations that use large quantities of bulk plutonium or uranium metal such as metal casting and pyro-chemistry operations.« less

  3. Joint Acoustic Propagation Experiment (JAPE-91) Workshop

    NASA Technical Reports Server (NTRS)

    Willshire, William L., Jr. (Compiler); Chestnutt, David (Compiler)

    1993-01-01

    The Joint Acoustic Propagation Experiment (JAPE), was conducted at the White Sands Missile Range, New Mexico, USA, during the period 11-28 Jul. 1991. JAPE consisted of various short and long range propagation experiments using various acoustic sources including speakers, propane cannons, helicopters, a 155 mm howitzer, and static high explosives. Of primary importance to the performance of theses tests was the extensive characterization of the atmosphere during these tests. This atmospheric characterization included turbulence measurements. A workshop to disseminate the results of JAPE-91 was held in Hampton, VA, on 28 Apr. 1993. This report is a compilation of the presentations made at the workshop along with a list of attendees and the agenda.

  4. A Review of Australian Investigations on Aeronautical Fatigue during the Period April 1985 to March 1987.

    DTIC Science & Technology

    1987-04-01

    to the edge, a process such as cold- expansion needs to be well proven before its adoption in service. Secondly, many Nomad aircraft operate in a...including the third front spar) has included extensive use of the FTI cold- expansion process in the fatigue-critical regions in 89 holes. Testing began...ANALYSIS AND REPAIR 9.4.1 Fatigue Life Enhancement (J.Y. Mann - ARL) Cold expansion of bolt holes was one of the techniques used to improve the

  5. Infrared thermography for examination of paper structure

    NASA Astrophysics Data System (ADS)

    Kiiskinen, Harri T.; Pakarinen, Pekka I.

    1998-03-01

    The paper industry has used IR cameras primarily for troubleshooting, where the most common examples include the examination of the condition of dryer fabrics and dryer cylinders and the analysis of moisture variations in a paper web. Another application extensively using IR thermography is non-destructive testing of composite materials. This paper presents some recently developed laboratory methods using an IR camera to examine paper structure. Specific areas include cockling, moisture content, thermal uniformity, mechanism of failure, and an analysis of the copying process.

  6. Clinical interpretation of antinuclear antibody tests in systemic rheumatic diseases

    PubMed Central

    Mercado, Monica Vázquez-Del; Chan, Edward K. L.

    2010-01-01

    Autoantibody tests have been used extensively in diagnosis and follow-up of patients in rheumatology clinics. Immunofluorescent antinuclear antibody test using HEp-2 cells is still considered the gold standard for screening of autoantibodies, and most of specific autoantibodies are currently tested by ELISA as a next step. Among the many autoantibody specificities described, some have been established as clinically useful diagnostic markers and are included in the classification criteria of diseases. Despite a long history of routine tests and attempts to standardize such assays, there are still limitations and problems that clinicians need to be aware of. Clinicians should be able to use autoantibody tests more efficiently and effectively with a basic knowledge on the significance of and potential problems in autoantibody tests. PMID:19277826

  7. The effect of pulse width and contact configuration on paresthesia coverage in spinal cord stimulation.

    PubMed

    Holsheimer, Jan; Buitenweg, Jan R; Das, John; de Sutter, Paul; Manola, Ljubomir; Nuttin, Bart

    2011-05-01

    In spinal cord stimulation for the management of chronic, intractable pain, a satisfactory analgesic effect can be obtained only when the stimulation-induced paresthesias cover all painful body areas completely or partially. To investigate the effect of stimulus pulse width (PW) and contact configuration (CC) on the area of paresthesia (PA), perception threshold (VPT), discomfort threshold (VDT), and usage range (UR) in spinal cord stimulation. Chronic pain patients were tested during a follow-up visit. They were stimulated monopolarly and with the CC giving each patient the best analgesia. VPT, VDT, and UR were determined for PWs of 90, 210, and 450 microseconds. The paresthesia contours at VDT were drawn on a body map and digitized; PA was calculated; and its anatomic composition was described. The effects of PW and CC on PA, VPT, VDT, and UR were tested statistically. Twenty-four of 31 tests with low thoracic stimulation and 8 of 9 tests with cervical stimulation gave a significant extension of PA at increasing PW. In 14 of 18 tests (low thoracic), a caudal extension was obtained (primarily in L5-S2). In cervical stimulation the extension was predominantly caudal as well. In contrast to VPT and VDT, UR is not significantly different when stimulating with any CC. PA extends caudally with increasing PW. The mechanism includes that the larger and smaller dorsal column fibers have a different mediolateral distribution and that smaller dorsal column fibers have a smaller UR and can be activated only when PW is sufficiently large. A similar effect of CC on PA is unlikely as long as electrodes with a large intercontact distance are applied.

  8. Short-term effects of oil ingestion on American kestrels (Falco sparverius).

    PubMed

    Pattee, O H; Franson, J C

    1982-04-01

    The Mexican Ixtoc oil well blowout resulted in extensive oil contamination along the Texas Gulf coast. This oil posed a potential hazard to migrating birds including the endangered peregrine falcon (Falco peregrinus). Laboratory tests with the American kestrel (Falco sparverius) indicated that the oil: water mixture gathered at the surface of the blowout site posed little acute hazard to falcons.

  9. Using Proactivity, Time Discounting, and the Theory of Planned Behavior to Identify Predictors of Retirement Planning

    ERIC Educational Resources Information Center

    Griffin, Barbara; Loe, David; Hesketh, Beryl

    2012-01-01

    This study developed and tested a model to identify the predictors of retirement planning based on an extension of the theory of planned behavior ([TPB], Ajzen, 1991) that included individual differences in proactivity and time discounting. The results showed that personal attitudes, sense of control, social influence, and stable traits have a…

  10. Can a Forest/Nonforest Change Map Improve the Precision of Forest Area, Volume, Growth, Removals, and Mortality Estimates?

    Treesearch

    Dale D. Gormanson; Mark H. Hansen; Ronald E. McRoberts

    2005-01-01

    In an extensive forest inventory, stratifications that use dual-date forest/nonforest classifications of Landsat Thematic Mapper data approximately 10 years apart are tested against similar classifications that use data from only one date. Alternative stratifications that further define edge strata as pixels adjacent to a forest/nonforest boundary are included in the...

  11. 77 FR 11367 - Defense Federal Acquisition Regulation Supplement; Extension of the Test Program for Negotiation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-24

    ... Federal Acquisition Regulation Supplement; Extension of the Test Program for Negotiation of Comprehensive... Program for Negotiation of Comprehensive Small Business Subcontracting Plans. DATES: Effective Date... Fiscal Year 2012, (Pub. L. 112-81). Section 866 amends the DoD Test Program for Negotiation of...

  12. Pre-Gas Drilling Drinking Water Testing--An Educational Opportunity for Extension

    ERIC Educational Resources Information Center

    Swistock, Brian; Clark, James

    2015-01-01

    The increase in shale gas drilling in Pennsylvania has resulted in thousands of landowners receiving predrilling testing of their drinking water. Landowners often have difficulty understanding test reports resulting in low awareness of pre-existing problems. Extension and several partners developed a program to improve understanding of…

  13. Global and Local Stress Analyses of McDonnell Douglas Stitched/RFI Composite Wing Stub Box

    NASA Technical Reports Server (NTRS)

    Wang, John T.

    1996-01-01

    This report contains results of structural analyses performed in support of the NASA structural testing of an all-composite stitched/RFI (resin film infusion) wing stub box. McDonnell Douglas Aerospace Company designed and fabricated the wing stub box. The analyses used a global/local approach. The global model contains the entire test article. It includes the all-composite stub box, a metallic load-transition box and a metallic wing-tip extension box. The two metallic boxes are connected to the inboard and outboard ends of the composite wing stub box, respectively. The load-transition box was attached to a steel and concrete vertical reaction structure and a load was applied at the tip of the extension box to bend the wing stub box upward. The local model contains an upper cover region surrounding three stringer runouts. In that region, a large nonlinear deformation was identified by the global analyses. A more detailed mesh was used for the local model to obtain more accurate analysis results near stringer runouts. Numerous analysis results such as deformed shapes, displacements at selected locations, and strains at critical locations are included in this report.

  14. Riparian rehabilitation using vegetation patches: field and laboratory investigations linking hydrology, vegetation and geomorphology

    NASA Astrophysics Data System (ADS)

    Rodriguez, J. F.; Gorrick, S.

    2010-12-01

    We present results of a riparian revegetation project on an oversized sand stream in eastern Australia. The Widden Brook in New South Wales has undergone extensive widening due to extraordinary floods in the 1950’s and is currently showing some signs of recovery. These include emergence of pool-riffle structure and stabilization of stream width, which are the result of upstream sediment control, riparian revegetation and livestock exclusion. Revegetation of a mild bend was carried out in 2004 using native plants in an arrangement that consisted of three vegetation patches. The same arrangement was tested in a reduced scale model in the laboratory, where extensive measurements of flow, sediment and bed changes provided insight into the links between hydrology, vegetation and geomorphology. Laboratory tests also included runs without vegetation and with a continuous vegetation cover. In terms of bank stability, the patches provided as much protection as the continuous vegetation. Based on the experiments, a series of analytical relationships were developed to help guide the design of vegetation patches focusing on the geomorphic stability of the whole reach instead of concentrating only on the near bank effects.

  15. Cross-border outbreak of extensively drug-resistant tuberculosis linked to a university in Romania.

    PubMed

    Popovici, O; Monk, Ph; Chemtob, D; Chiotan, D; Freidlin, P J; Groenheit, R; Haanperä, M; Homorodean, D; Mansjö, M; Robinson, E; Rorman, E; Smith, G; Soini, H; Van Der Werf, M J

    2018-05-01

    Extensively drug-resistant (XDR) tuberculosis (TB) poses a threat to public health due to its complicated, expensive and often unsuccessful treatment. A cluster of three XDR TB cases was detected among foreign medical students of a Romanian university. The contact investigations included tuberculin skin testing or interferon gamma release assay, chest X-ray, sputum smear microscopy, culture, drug susceptibility testing, genotyping and whole-genome sequencing (WGS), and were addressed to students, personnel of the university, family members or other close contacts of the cases. These investigations increased the total number of cases to seven. All confirmed cases shared a very similar WGS profile. Two more cases were epidemiologically linked, but no laboratory confirmation exists. Despite all the efforts done, the source of the outbreak was not identified, but the transmission was controlled. The investigation was conducted by a team including epidemiologists and microbiologists from five countries (Finland, Israel, Romania, Sweden and the UK) and from the European Centre for Disease Prevention and Control. Our report shows how countries can collaborate to control the spread of XDR TB by exchanging information about cases and their contacts to enable identification of additional cases and transmission and to perform the source investigation.

  16. Effects of Acute Fatigue of the Hip Flexor Muscles on Hamstring Muscle Extensibility.

    PubMed

    Muyor, José M; Arrabal-Campos, Francisco M

    2016-12-01

    The purpose of the present study was to evaluate the influence of acute fatigue of the hip flexor muscles on scores attained in tests frequently used in literature to measure hamstring muscle extensibility, namely the passive straight leg raise (PSLR), active straight leg raise (ASLR), passive knee extension (PKE), active knee extension (AKE), sit-and-reach (SR) and toe-touch (TT) tests. A total of seventy-five healthy and recreationally active adults voluntarily participated in this study. To reach fatigue, the participants actively lifted their legs alternately as many times as possible. In the passive tests, the results were 7.10 ± 5.21° and 5.68 ± 4.54° higher (p < 0.01) for PSLR and PKE tests, respectively, after acute fatigue. However, in the ASLR test, the results were lower post-fatigue than pre-fatigue (mean difference = -5.30° ± 9.51°; p < 0.01). The AKE, SR and TT tests did not show significant differences between pre- and post-fatigue (p > 0.05). Moderate (r = 0.40) to high (r = 0.97) correlation coefficients were found, which were statistically significant among all the measured flexibility tests both pre- and post-fatigue. In conclusion, the active implication of the hip flexor muscles until reaching fatigue had acute influences on the results of the PSLR, PKE and ASLR tests, but not on the results of the AKE, SR and TT tests. It is recommended to use the AKE test to assess hamstring muscle extensibility in situations where athletes show fatigue in their hip flexor muscles.

  17. Normal neurodynamic responses of the femoral slump test.

    PubMed

    Lai, Weng-Hang; Shih, Yi-Fen; Lin, Pei-Ling; Chen, Wen-Yin; Ma, Hsiao-Li

    2012-04-01

    Femoral slump test is a neurodynamic testing, which could be used to assess the mechanosensitivity of the femoral component of the nervous system. Although Trainor and Pinnington reported the diagnosis accuracy of the femoral slump test, the neurodynamic responses of the femoral slump test have never been studied. The purposes of this study were to evaluate whether maneuvers that changed the nerve tension altered the responses of the femoral slump test and if these responses were influenced by gender and leg dominance; and to identify the correlations between flexibility and measured hip extension angle. Thirty-two asymptomatic subjects (16 males, 16 females) were recruited. The femoral slump test was performed in trunk slump and neutral positions, and cervical extension was used as the structure differential technique. Hip extension angle and visual analog scale (VAS) of thigh pain was measured during the test. Our results showed the decrease of nerve tension significantly increased hip extension ROM (P < 0.001) and lowered pain intensity (P < 0.001). The hip extension ROM was similar between genders but smaller for the dominant leg, as compared to the non-dominant side (P < 0.05); and the hip ROM did not correlate with any of the flexibility indices (P > 0.05). These findings indicated that femoral slump test resulted in normal neurodynamic responses in individuals free of lower extremity problems, and these responses were independent of the influence of muscle flexibility or gender. Future research should emphasize the use of femoral slump test in patient groups such as low back and anterior knee pain. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Contact investigation after a fatal case of extensively drug-resistant tuberculosis (XDR-TB) in an aircraft, Germany, July 2013

    PubMed Central

    an der Heiden, Maria; Hauer, Barbara; Fiebig, Lena; Glaser-Paschke, Gisela; Stemmler, Markus; Simon, Claudia; Rüsch-Gerdes, Sabine; Gilsdorf, Andreas; Haas, Walter

    2017-01-01

    In July 2013, a passenger died of infectious extensively drug-resistant tuberculosis (XDR-TB) on board of an aircraft after a 3-hour flight from Turkey to Germany. Initial information indicated the patient had moved about the aircraft coughing blood. We thus aimed to contact and inform all persons exposed within the aircraft and to test them for newly acquired TB infection. Two-stage testing within 8 weeks from exposure and at least 8 weeks after exposure was suggested, using either interferon gamma release assays (IGRAs) or tuberculin skin test (TST). The TST cut-off was defined at a diameter > 10 mm; for differentiation between conversion and boosting, conversion was defined as increase of skin induration > 5 mm. Overall, 155 passengers and seven crew members were included in the investigation: the questionnaire response rate was 83%; 112 (69%) persons were tested at least once for TB infection. In one passenger, who sat next to the area where the patient died, a test conversion was registered. As of March 2017, no secondary active TB cases have been reported. We describe an unusual situation in which we applied contact tracing beyond existing European guidelines; we found one latent tuberculosis infection in a passenger, which we consider probably newly acquired. PMID:28367796

  19. Evaluation of high temperature structural adhesives for extended service, phase 4

    NASA Technical Reports Server (NTRS)

    Hendricks, C. L.; Hill, S. G.; Hale, J. N.

    1985-01-01

    The evaluation of three phenylquinoxaline polymers as high temperature structural adhesives is presented. These included an experimental crisskubjabke oiktner (X-PQ) and two experimental materials (PPQ-2501) and (PPQ-HC). Lap shear, crack extension, and climing drum peel specimens were fabricated from all three polymers, and tested after thermal, combined thermal/humidity, and stressed Skydrol exposure. All three polymers generally performed well as adhesives at initial test temperatures from 219K (-67 F) to 505K (450 F) and after humidity exposure. The 644K (700 F) cured test specimens exhibited superior Skydrol resistance and thermal stability at 505K (450 F) when compared to the 602K (625 F) cured test specimens.

  20. Minilaparotomy vs. laparoscopic cholecystectomy: results of a randomized clinical trial.

    PubMed

    Velázquez-Mendoza, José Dolores; Villagrán-Murillo, Francisco Javier; González-Ojeda, Alejandro

    2012-01-01

    Currently, laparoscopic cholecystectomy is considered the gold standard for treatment of gallstones with advantages in regard to postoperative pain, hospital stay, early return to activities of daily living and acceptable cosmetic results. Open cholecystectomy in the form of minilaparotomy may be an effective alternative for the management of symptomatic cholelithiasis. We undertook this study to compare the results of laparoscopic cholecystectomy and minilaparotomy cholecystectomy techniques. methods: We conducted a randomized clinical trial between January 2009 and December 2009. We included patients with symptomatic cholelithiasis divided into two groups: group A--minilaparotomy and group B--laparoscopic cholecystectomy. End-point variables were age, gender, pre- and postoperative diagnosis, operative time, conversion or extension, hospital stay, complications and pain. Statistical analysis included Fisher's exact test, χ(2) test and Student t test. There were 88 patients with cholelithiasis: 37 men and 51 women. Mean age was 45.65 years. There were 45 patients in Group A and 43 patients in Group B. Mean operative time was 79.02 min for minilaparotomy and 86.04 min for laparoscopic cholecystectomy (p = 0.33). Average hospital stay was 2.75 days for minilaparotomy and of 2.02 days for laparoscopy (p = 0.60). Complications of minilaparotomy were demonstrated in 6.6% of patients and for laparoscopic cholecystectomy in 16.3% of patients (p = 0.16). There were three extensions and five conversions. Minilaparotomy cholecystectomy has results similar to laparoscopic cholecystectomy.

  1. Overview of Non-nuclear Testing of the Safe, Affordable 30-kW Fission Engine, Including End-to-End Demonstrator Testing

    NASA Technical Reports Server (NTRS)

    VanDyke, M. K.; Martin, J. J.; Houts, M. G.

    2003-01-01

    Successful development of space fission systems will require an extensive program of affordable and realistic testing. In addition to tests related to design/development of the fission system, realistic testing of the actual flight unit must also be performed. At the power levels under consideration (3-300 kW electric power), almost all technical issues are thermal or stress related and will not be strongly affected by the radiation environment. These issues can be resolved more thoroughly, less expensively, and in a more timely fashing with nonnuclear testing, provided it is prototypic of the system in question. This approach was used for the safe, affordable fission engine test article development program and accomplished viz cooperative efforts with Department of Energy labs, industry, universiites, and other NASA centers. This Technical Memorandum covers the analysis, testing, and data reduction of a 30-kW simulated reactor as well as an end-to-end demonstrator, including a power conversion system and an electric propulsion engine, the first of its kind in the United States.

  2. GLSENS: A Generalized Extension of LSENS Including Global Reactions and Added Sensitivity Analysis for the Perfectly Stirred Reactor

    NASA Technical Reports Server (NTRS)

    Bittker, David A.

    1996-01-01

    A generalized version of the NASA Lewis general kinetics code, LSENS, is described. The new code allows the use of global reactions as well as molecular processes in a chemical mechanism. The code also incorporates the capability of performing sensitivity analysis calculations for a perfectly stirred reactor rapidly and conveniently at the same time that the main kinetics calculations are being done. The GLSENS code has been extensively tested and has been found to be accurate and efficient. Nine example problems are presented and complete user instructions are given for the new capabilities. This report is to be used in conjunction with the documentation for the original LSENS code.

  3. Non-Destructive Techniques Based on Eddy Current Testing

    PubMed Central

    García-Martín, Javier; Gómez-Gil, Jaime; Vázquez-Sánchez, Ernesto

    2011-01-01

    Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. This paper includes an overview of the fundamentals and main variables of eddy current testing. It also describes the state-of-the-art sensors and modern techniques such as multi-frequency and pulsed systems. Recent advances in complex models towards solving crack-sensor interaction, developments in instrumentation due to advances in electronic devices, and the evolution of data processing suggest that eddy current testing systems will be increasingly used in the future. PMID:22163754

  4. Development tests for the 2.5 megawatt Mod-2 wind turbine generator

    NASA Technical Reports Server (NTRS)

    Andrews, J. S.; Baskin, J. M.

    1982-01-01

    The 2.5 megawatt MOD-2 wind turbine generator test program is discussed. The development of the 2.5 megawatt MOD-2 wind turbine generator included an extensive program of testing which encompassed verification of analytical procedures, component development, and integrated system verification. The test program was to assure achievement of the thirty year design operational life of the wind turbine system as well as to minimize costly design modifications which would otherwise have been required during on site system testing. Computer codes were modified, fatigue life of structure and dynamic components were verified, mechanical and electrical component and subsystems were functionally checked and modified where necessary to meet system specifications, and measured dynamic responses of coupled systems confirmed analytical predictions.

  5. Non-destructive techniques based on eddy current testing.

    PubMed

    García-Martín, Javier; Gómez-Gil, Jaime; Vázquez-Sánchez, Ernesto

    2011-01-01

    Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. This paper includes an overview of the fundamentals and main variables of eddy current testing. It also describes the state-of-the-art sensors and modern techniques such as multi-frequency and pulsed systems. Recent advances in complex models towards solving crack-sensor interaction, developments in instrumentation due to advances in electronic devices, and the evolution of data processing suggest that eddy current testing systems will be increasingly used in the future.

  6. [Tuberculin test responses of tuberculosis patients].

    PubMed

    Pina, J M; Domínguez, A; Alcaide, J; Alvarez, J; Camps, N; Díez, M; Godoy, P; Jansá, J M; Minguell, S

    2002-12-01

    To determine the response of tuberculosis patients to tuberculin skin tests. The results of skin tests used for initial assessment of tuberculosis patients in Catalonia were reviewed (Multicenter Tuberculosis Research Project). Negative skin tests were those with indurations < 5 mm; positive tests were those with indurations measuring > or = 5 mm. Individuals were classed as having or not having risk factors for developing tuberculosis and those without risk factors were classified by age, location and extension of tuberculosis. Negative skin tests were seen in 1,566 patients (23%). Negative tests were more common in patients with risk factors, significantly so in those undergoing immunosuppressant therapy (50%) or with HIV infection (61%). Negative tests were less prevalent in patients with no risk factors (13%) and, among them, in children (1%), in patients between 15 and 29 years of age (10%) or in those with non-pulmonary forms (10%). Negative tests were significantly more prevalent among patients 60 to 74 years of age (27%), those over 74 (44%), and those whose disease was pulmonary and extrapulmonary (26%) or disseminated (64%). No significant differences in induration size of positive skin tests were observed for patients with and without risk factors (including HIV infection or non-infection). A normal distribution of induration size was observed in all groups. A negative tuberculin skin test for initial assessment should be interpreted in function of the presence or absence of risk factors, age, location or extension of tuberculosis. When a skin test is positive, the response will be similar whether or not an immunodepressant factor is present.

  7. Predictive value of health-related fitness tests for self-reported mobility difficulties among high-functioning elderly men and women.

    PubMed

    Hämäläinen, H Pauliina; Suni, Jaana H; Pasanen, Matti E; Malmberg, Jarmo J; Miilunpalo, Seppo I

    2006-06-01

    The functional independence of elderly populations deteriorates with age. Several tests of physical performance have been developed for screening elderly persons who are at risk of losing their functional independence. The purpose of the present study was to investigate whether several components of health-related fitness (HRF) are valid in predicting the occurrence of self-reported mobility difficulties (MD) among high-functioning older adults. Subjects were community-dwelling men and women, born 1917-1941, who participated in the assessment of HRF [6.1-m (20-ft) walk, one-leg stand, backwards walk, trunk side-bending, dynamic back extension, one-leg squat, 1-km walk] and who were free of MD in 1996 (no difficulties in walking 2- km, n=788; no difficulties in climbing stairs, n=647). Postal questionnaires were used to assess the prevalence of MD in 1996 and the occurrence of new MD in 2002. Logistic regression analysis was used as the statistical method. Both inability to perform the backwards walk and a poorer result in it were associated with risk of walking difficulties in the logistic model, with all the statistically significant single test items included. Results of 1-km walk time and one-leg squat strength test were also associated with risk, although the squat was statistically significant only in two older birth cohorts. Regarding stair-climbing difficulties, poorer results in the 1-km walk, dynamic back extension and one-leg squat tests were associated with increased risk of MD. The backwards walk, one-leg squat, dynamic back extension and 1-km walk tests were the best predictors of MD. These tests are recommended for use in screening high-functioning older people at risk of MD, as well as to target physical activity counseling to those components of HRF that are important for functional independence.

  8. Spray nozzle investigation for the Improved Helicopter Icing Spray System (IHISS)

    NASA Technical Reports Server (NTRS)

    Peterson, Andrew A.; Oldenburg, John R.

    1990-01-01

    A contract has been awarded by the U.S. Army to design, fabricate and test a replacement for the existing Helicopter Icing Spray System. Data are shown for extensive bench and icing tunnel test programs used to select and modify an improved spray nozzle. The IHISS, capable of deployment from any CH-47 helicopter, will include new icing spray nozzles and pneumatic pressure source, and a significantly larger water tank and spray boom. The resulting system will provide a significantly larger icing cloud with droplet characteristics closely matching natural icing conditions.

  9. Virtual sensor models for real-time applications

    NASA Astrophysics Data System (ADS)

    Hirsenkorn, Nils; Hanke, Timo; Rauch, Andreas; Dehlink, Bernhard; Rasshofer, Ralph; Biebl, Erwin

    2016-09-01

    Increased complexity and severity of future driver assistance systems demand extensive testing and validation. As supplement to road tests, driving simulations offer various benefits. For driver assistance functions the perception of the sensors is crucial. Therefore, sensors also have to be modeled. In this contribution, a statistical data-driven sensor-model, is described. The state-space based method is capable of modeling various types behavior. In this contribution, the modeling of the position estimation of an automotive radar system, including autocorrelations, is presented. For rendering real-time capability, an efficient implementation is presented.

  10. Experimental investigation of hypersonic aerodynamics

    NASA Technical Reports Server (NTRS)

    Heinemann, K.; Intrieri, Peter F.

    1987-01-01

    An extensive series of ballistic range tests are currently being conducted at the Ames Research Center. These tests are intended to investigate the hypersonic aerodynamic characteristics of two basic configurations, which are: the blunt-cone Galileo probe which is scheduled to be launched in late 1989 and will enter the atmosphere of Jupiter in 1994, and a generic slender cone configuration to provide experimental aerodynamic data including good flow-field definition which computational aerodynamicists could use to validate their computer codes. Some of the results obtained thus far are presented and work for the near future is discussed.

  11. The Importance of Rare Subtypes in Diagnosis and Treatment of Peripheral Neuropathy: A Review.

    PubMed

    Callaghan, Brian C; Price, Raymond S; Chen, Kevin S; Feldman, Eva L

    2015-12-01

    Peripheral neuropathy is a prevalent condition that usually warrants a thorough history and examination but has limited diagnostic evaluation. However, rare localizations of peripheral neuropathy often require more extensive diagnostic testing and different treatments. To describe rare localizations of peripheral neuropathy, including the appropriate diagnostic evaluation and available treatments. References were identified from PubMed searches conducted on May 29, 2015, with an emphasis on systematic reviews and randomized clinical trials. Articles were also identified through the use of the authors' own files. Search terms included common rare neuropathy localizations and their causes, as well as epidemiology, pathophysiology, diagnosis, and treatment. Diffuse, nonlength-dependent neuropathies, multiple mononeuropathies, polyradiculopathies, plexopathies, and radiculoplexus neuropathies are rare peripheral neuropathy localizations that often require extensive diagnostic testing. Atypical neuropathy features, such as acute/subacute onset, asymmetry, and/or motor predominant signs, are frequently present. The most common diffuse, nonlength-dependent neuropathies are Guillain-Barré syndrome, chronic inflammatory demyelinating polyneuropathy, multifocal motor neuropathy, and amyotrophic lateral sclerosis. Effective disease-modifying therapies exist for many diffuse, nonlength-dependent neuropathies including Guillain-Barré syndrome, chronic inflammatory demyelinating polyneuropathy, multifocal motor neuropathy, and some paraprotein-associated demyelinating neuropathies. Vasculitic neuropathy (multiple mononeuropathy) also has efficacious treatment options, but definitive evidence of a treatment effect for IgM anti-MAG neuropathy and diabetic amyotrophy (radiculoplexus neuropathy) is lacking. Recognition of rare localizations of peripheral neuropathy is essential given the implications for diagnostic testing and treatment. Electrodiagnostic studies are an important early step in the diagnostic evaluation and provide information on the localization and pathophysiology of nerve injury.

  12. Wind-tunnel Tests of a Cyclogiro Rotor

    NASA Technical Reports Server (NTRS)

    Wheatley, John B; Windler, Ray

    1935-01-01

    During an extensive study of all types of rotating wings, the NACA examined the cyclogiro rotor and made an aerodynamic analysis of that system (reference 1). The examination disclosed that such a machine had sufficient promise to justify an experimental investigation; a model with a diameter and span of 8 feet was therefore constructed and tested in the 20-foot wind tunnel during 1934. The experimental work included tests of the effect of the motion upon the rotor forces during the static-lift and forward-flight conditions at several rotor speeds and the determination of the relations between the forces generated by the rotor and the power required by it.

  13. Parallelization of Unsteady Adaptive Mesh Refinement for Unstructured Navier-Stokes Solvers

    NASA Technical Reports Server (NTRS)

    Schwing, Alan M.; Nompelis, Ioannis; Candler, Graham V.

    2014-01-01

    This paper explores the implementation of the MPI parallelization in a Navier-Stokes solver using adaptive mesh re nement. Viscous and inviscid test problems are considered for the purpose of benchmarking, as are implicit and explicit time advancement methods. The main test problem for comparison includes e ects from boundary layers and other viscous features and requires a large number of grid points for accurate computation. Ex- perimental validation against double cone experiments in hypersonic ow are shown. The adaptive mesh re nement shows promise for a staple test problem in the hypersonic com- munity. Extension to more advanced techniques for more complicated ows is described.

  14. 77 FR 38289 - Agency Information Collection Activities: Announcement of Board Approval Under Delegated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-27

    ... comment for 30 days to revise, without extension, Capital Assessments and Stress Testing information..., without extension, the Capital Assessments and Stress Testing information collection (FR Y-14A/Q/M). In...

  15. Modelling of LOCA Tests with the BISON Fuel Performance Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williamson, Richard L; Pastore, Giovanni; Novascone, Stephen Rhead

    2016-05-01

    BISON is a modern finite-element based, multidimensional nuclear fuel performance code that is under development at Idaho National Laboratory (USA). Recent advances of BISON include the extension of the code to the analysis of LWR fuel rod behaviour during loss-of-coolant accidents (LOCAs). In this work, BISON models for the phenomena relevant to LWR cladding behaviour during LOCAs are described, followed by presentation of code results for the simulation of LOCA tests. Analysed experiments include separate effects tests of cladding ballooning and burst, as well as the Halden IFA-650.2 fuel rod test. Two-dimensional modelling of the experiments is performed, and calculationsmore » are compared to available experimental data. Comparisons include cladding burst pressure and temperature in separate effects tests, as well as the evolution of fuel rod inner pressure during ballooning and time to cladding burst. Furthermore, BISON three-dimensional simulations of separate effects tests are performed, which demonstrate the capability to reproduce the effect of azimuthal temperature variations in the cladding. The work has been carried out in the frame of the collaboration between Idaho National Laboratory and Halden Reactor Project, and the IAEA Coordinated Research Project FUMAC.« less

  16. 76 FR 24060 - Proposed Extension of Existing Information Collection; Testing, Evaluation, and Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-29

    ... Extension of Existing Information Collection; Testing, Evaluation, and Approval of Mining Products AGENCY... Reduction Act of 1995 [44 U.S.C. 3506(c)(2)(A)]. This program helps to ensure that requested data can be..., testing, approval and certification, and quality control of mining equipment and components, materials...

  17. PHENIX Muon Piston Calorimeter (MPC) APD and Prototype MPC Extension (MPC-EX) Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lajoie, John

    2013-06-20

    This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) and the experimenters of Muon Piston Calorimeter Extension (MPC-EX) Collaboration who have committed to participate in beam tests to be carried out during the 2013- 2014 Fermilab Test Beam Facility program.

  18. Fixating picture boundaries does not eliminate boundary extension: Implications for scene representation

    PubMed Central

    Gagnier, Kristin Michod; Dickinson, Christopher A.; Intraub, Helene

    2015-01-01

    Observers frequently remember seeing more of a scene than was shown (boundary extension). Does this reflect a lack of eye fixations to the boundary region? Single-object photographs were presented for 14–15 s each. Main objects were either whole or slightly cropped by one boundary, creating a salient marker of boundary placement. All participants expected a memory test, but only half were informed that boundary memory would be tested. Participants in both conditions made multiple fixations to the boundary region and the cropped region during study. Demonstrating the importance of these regions, test-informed participants fixated them sooner, longer, and more frequently. Boundary ratings (Experiment 1) and border adjustment tasks (Experiments 2–4) revealed boundary extension in both conditions. The error was reduced, but not eliminated, in the test-informed condition. Surprisingly, test knowledge and multiple fixations to the salient cropped region, during study and at test, were insufficient to overcome boundary extension on the cropped side. Results are discussed within a traditional visual-centric framework versus a multisource model of scene perception. PMID:23547787

  19. Fixating picture boundaries does not eliminate boundary extension: implications for scene representation.

    PubMed

    Michod Gagnier, Kristin; Dickinson, Christopher A; Intraub, Helene

    2013-01-01

    Observers frequently remember seeing more of a scene than was shown (boundary extension). Does this reflect a lack of eye fixations to the boundary region? Single-object photographs were presented for 14-15 s each. Main objects were either whole or slightly cropped by one boundary, creating a salient marker of boundary placement. All participants expected a memory test, but only half were informed that boundary memory would be tested. Participants in both conditions made multiple fixations to the boundary region and the cropped region during study. Demonstrating the importance of these regions, test-informed participants fixated them sooner, longer, and more frequently. Boundary ratings (Experiment 1) and border adjustment tasks (Experiments 2-4) revealed boundary extension in both conditions. The error was reduced, but not eliminated, in the test-informed condition. Surprisingly, test knowledge and multiple fixations to the salient cropped region, during study and at test, were insufficient to overcome boundary extension on the cropped side. Results are discussed within a traditional visual-centric framework versus a multisource model of scene perception.

  20. The relationship between balance performance, lumbar extension strength, trunk extension endurance, and pain in participants with chronic low back pain, and those without.

    PubMed

    Behennah, Jessica; Conway, Rebecca; Fisher, James; Osborne, Neil; Steele, James

    2018-03-01

    Chronic low back pain is associated with lumbar extensor deconditioning. This may contribute to decreased neuromuscular control and balance. However, balance is also influenced by the hip musculature. Thus, the purpose of this study was to examine balance in both asymptomatic participants and those with chronic low back pain, and to examine the relationships among balance, lumbar extension strength, trunk extension endurance, and pain. Forty three asymptomatic participants and 21 participants with non-specific chronic low back pain underwent balance testing using the Star Excursion Balance Test, lumbar extension strength, trunk extension endurance, and pain using a visual analogue scale. Significant correlations were found between lumbar extension strength and Star Excursion Balance Test scores in the chronic low back pain group (r = 0.439-0.615) and in the asymptomatic group (r = 0.309-0.411). Correlations in the chronic low back pain group were consistently found in posterior directions. Lumbar extension strength explained ~19.3% to ~37.8% of the variance in Star Excursion Balance Test scores for the chronic low back pain group and ~9.5% to ~16.9% for the asymptomatic group. These results suggest that the lumbar extensors may be an important factor in determining the motor control dysfunctions, such as limited balance, that arise in chronic low back pain. As such, specific strengthening of this musculature may be an approach to aid in reversing these dysfunctions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Isokinetic Extension Strength Is Associated With Single-Leg Vertical Jump Height.

    PubMed

    Fischer, Felix; Blank, Cornelia; Dünnwald, Tobias; Gföller, Peter; Herbst, Elmar; Hoser, Christian; Fink, Christian

    2017-11-01

    Isokinetic strength testing is an important tool in the evaluation of the physical capacities of athletes as well as for decision making regarding return to sports after anterior cruciate ligament (ACL) reconstruction in both athletes and the lay population. However, isokinetic testing is time consuming and requires special testing equipment. A single-jump test, regardless of leg dominance, may provide information regarding knee extension strength through the use of correlation analysis of jump height and peak torque of isokinetic muscle strength. Cross-sectional study; Level of evidence, 3. A total of 169 patients who underwent ACL reconstruction were included in this study. Isokinetic testing was performed on the injured and noninjured legs. Additionally, a single-leg countermovement jump was performed to assess jump height using a jump accelerometer sensor. Extension strength values were used to assess the association between isokinetic muscle strength and jump height. The sample consisted of 60 female (mean age, 20.8 ± 8.3 years; mean weight, 61.7 ± 6.5 kg; mean height, 167.7 ± 5.3 cm) and 109 male (mean age, 23.2 ± 7.7 years; mean weight, 74.6 ± 10.2 kg; mean height, 179.9 ± 6.9 cm) patients. Bivariate correlation analysis showed an association ( r = 0.56, P < .001) between jump height and isokinetic extension strength on the noninvolved side as well as an association ( r = 0.52, P < .001) for the involved side. Regression analysis showed that in addition to jump height (beta = 0.49, P < .001), sex (beta = -0.17, P = .008) and body mass index (beta = 0.37, P < .001) affected isokinetic strength. The final model explained 51.1% of the variance in isokinetic muscle strength, with jump height having the strongest impact (beta = 0.49, P < .001) and explaining 31.5% of the variance. Initial analysis showed a strong association between isokinetic strength and jump height. The study population encompassed various backgrounds, skill levels, and activity profiles, which might have affected the outcome. Even after controlling for age and sex, isokinetic strength was still moderately associated with jump height. Therefore, the jump technique and type of sport should be considered in future research.

  2. Rehabilitation of the elbow extension with motor imagery in a patient with quadriplegia after tendon transfer.

    PubMed

    Grangeon, Murielle; Guillot, Aymeric; Sancho, Pierre-Olivier; Picot, Marion; Revol, Patrice; Rode, Gilles; Collet, Christian

    2010-07-01

    To test the effect of a postsurgical motor imagery program in the rehabilitation of a patient with quadriplegia. Crossover design with kinematic analysis. Rehabilitation Hospital of Lyon. Study approved by the local Human Research Ethics Committee. C6-level injured patient (American Spinal Injury Association Impairment Scale grade A) with no voluntary elbow extension (triceps brachialis score 1). The surgical procedure was to transfer the distal insertion of the biceps brachii onto the triceps tendon of both arms. The postsurgical intervention on the left arm included 10 sessions of physical rehabilitation followed by 10 motor imagery sessions of 30 minutes each. The patient underwent 5 sessions a week during 2 consecutive weeks. The motor imagery content included mental representations based on elbow extension involved in goal-directed movements. The rehabilitation period of the right arm was reversed, with motor imagery performed first, followed by physical therapy. The kinematics of upper-limb movements was recorded (movement time and variability) before and after each type of rehabilitation period. A long-term retention test was performed 1 month later. Motor imagery training enhanced motor recovery by reducing hand trajectory variability-that is, improving smoothness. Motor performance then remained stable over 1 month. Motor imagery improved motor recovery when associated with physical therapy, with motor performance remaining stable over the 1-month period. We concluded that motor imagery should be successfully associated with classic rehabilitation procedure after tendon transfer. Physical sessions may thus be shortened if too stressful or painful. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  3. Fun During Knee Rehabilitation: Feasibility and Acceptability Testing of a New Android-Based Training Device

    PubMed Central

    Weber-Spickschen, Thomas Sanjay; Colcuc, Christian; Hanke, Alexander; Clausen, Jan-Dierk; James, Paul Abraham; Horstmann, Hauke

    2017-01-01

    Purpose: The initial goals of rehabilitation after knee injuries and operations are to achieve full knee extension and to activate quadriceps muscle. In addition to regular physiotherapy, an android-based knee training device is designed to help patients achieve these goals and improve compliance in the early rehabilitation period. This knee training device combines fun in a computer game with muscular training or rehabilitation. Our aim was to test the feasibility and acceptability of this new device. Methods: 50 volunteered subjects enrolled to test out the computer game aided device. The first game was the high-striker game, which recorded maximum knee extension power. The second game involved controlling quadriceps muscular power to simulate flying an aeroplane in order to record accuracy of muscle activation. The subjects evaluated this game by completing a simple questionnaire. Results: No technical problem was encountered during the usage of this device. No subjects complained of any discomfort after using this device. Measurements including maximum knee extension power, knee muscle activation and control were recorded successfully. Subjects rated their experience with the device as either excellent or very good and agreed that the device can motivate and monitor the progress of knee rehabilitation training. Conclusion: To the best of our knowledge, this is the first android-based tool available to fast track knee rehabilitation training. All subjects gave very positive feedback to this computer game aided knee device. PMID:29081870

  4. Principled Design of an Augmented Reality Trainer for Medics

    DTIC Science & Technology

    2018-04-13

    retake test is scheduled. In addition, extensive simulation capstone scenarios are run with a full body manikin that includes airway management...platform so they could run with high quality graphical resolution. We updated the underlying data models to reflect the training scenario parameters...Sedeh, P., Schumann, M., & Groeben, H. (2009). Laryngoscopy via Macintosh blade versus GlideScope: Success rate and time for endotracheal intubation

  5. An influence of extremal edges on boundary extension.

    PubMed

    Hale, Ralph G; Brown, James M; McDunn, Benjamin A; Siddiqui, Aisha P

    2015-08-01

    Studies have shown that people consistently remember seeing more of a studied scene than was physically present (e.g., Intraub & Richardson Journal of Experimental Psychology: Learning, Memory, and Cognition, 15, 179-187, 1989). This scene memory error, known as boundary extension, has been suggested to occur due to an observer's failure to differentiate between the contributing sources of information, including the sensory input, amodal continuation beyond the view boundaries, and contextual associations with the main objects and depicted scene locations (Intraub, 2010). Here, "scenes" made of abstract shapes on random-dot backgrounds, previously shown to elicit boundary extension (McDunn, Siddiqui, & Brown Psychonomic Bulletin & Review, 21, 370-375, 2014), were compared with versions made with extremal edges (Palmer & Ghose Psychological Science, 19, 77-84, 2008) added to their borders, in order to examine how boundary extension is influenced when amodal continuation at the borders' view boundaries is manipulated in this way. Extremal edges were expected to reduce boundary extension as compared to the same scenes without them, because extremal edge boundaries explicitly indicate an image's end (i.e., they do not continue past the view boundary). A large and a small difference (16 % and 40 %) between the close and wide-angle views shown during the experiment were tested to examine the effects of both boundary extension and normalization with and without extremal edges. Images without extremal edges elicited typical boundary extension for the 16 % size change condition, whereas the 40 % condition showed signs of normalization. With extremal edges, a reduced amount of boundary extension occurred for the 16 % condition, and only normalization was found for the 40 % condition. Our findings support and highlight the importance of amodal continuation at the view boundaries as a component of boundary extension.

  6. Three-dimensional variations in the lower limb caused by the windlass mechanism

    PubMed Central

    Tovaruela-Carrión, Natalia; Távara-Vidalón, Priscila; Fernández-Seguín, Lourdes María

    2017-01-01

    Background The windlass mechanism was described as the effect caused by the extension of the first metatarsalphalangeal joint (1st MTPJ). Quantify the degrees of movement produced in the leg by means of the Bioval® sensor system, after performing two measurements in the 1st MTPJ, 45° extension and maximum extension. Methods Tests-post-test study with just one intervention group, performed in the Clinical Podiatry Area of the Faculty of Nursing, Physiotherapy and Podiatry of the University of Seville. Subjects were included as of age 20, with a value from 0° to 3° valgus, Helbing line, a value from 0° to +5° for the foot postural index, and a localisation axis for the normalised subtalar joint. Subjects with surgical operations of the first ray, fractures and surgical operations in the leg, pathologies in the first ray and rheumatic diseases were excluded. Measurement was performed with the Bioval® system by means of inserting four sensors in the bone structures involved in the windlass mechanism. Results With the 45° wedge we observed a direct correlation among the variables extension–plantar flexion 1st MTPJ and rotation of the femur. With maximal extension of the 1st MTPJ we obtained a direct relationship between the variable extension of the 1st MTPJ and the variables plantar flexion and prono-supination of the 1st metatarsal as well as with the variables tibia rotation and femur rotation. Conclusion Kinematic analysis suggested that the higher the degree of extension the more movement will be generated. This reduces the level of impact the more distal the structure with respect to the 1st MTPJ, which has an impact on the entire leg. Because of the kinematic system used wasn’t suitable, its impact wasn’t exactly quantified. PMID:29302385

  7. Test anxiety in Indian children: a cross-cultural perspective.

    PubMed

    Bodas, Jaee; Ollendick, Thomas H; Sovani, Anuradha V

    2008-10-01

    The present investigation examined test anxiety in Indian children from a cross-cultural perspective. Test anxiety has been studied extensively in western countries but much less so in eastern countries. Furthermore, the cross-cultural research conducted in eastern countries possesses significant limitations and continues to possess a western bias. The present research attempted to advance cross-cultural research on test anxiety by adopting Berry's imposed etic-emic-derived etic methodology. Participants included 231 schoolchildren. Qualitative data were collected to examine culture-specific variables (emic considerations) using structured focus groups and open-ended questions. Next, quantitative data were collected using translated and adapted versions of Spielberger's Test Anxiety Inventory and the FRIEDBEN Test Anxiety Scale. Qualitative data indicated culture-specific elements of test anxiety in Indian youth, including the high stakes associated with exam performance and future schooling as well as the role of somatization and social derogation in the phenomenological experience of test anxiety. Although quantitative findings failed to confirm the importance of high-stakes environments on test anxiety, the importance of somatization and social derogation was substantiated. Ongoing desensitization to test anxiety and enhanced coping responses were proposed as possible explanations for the obtained relations.

  8. The PANDA tests for SBWR certification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varadi, G.; Dreier, J.; Bandurski, Th.

    1996-03-01

    The ALPHA project is centered around the experimental and analytical investigation of the long-term decay heat removal from the containments of the next generation of {open_quotes}passive{close_quotes} ALWRs. The project includes integral system tests in the large-scale (1:25 in volume) PANDA facility as well as several other series of tests and supporting analytical work. The first series of experiments to be conducted in PANDA have become a required experimental element in the certification process for the General Electric Simplified Boiling Water Reactor (SBWR). The PANDA general experimental philosophy, facility design, scaling, and instrumentation are described. Steady-state PCCS condenser performance tests andmore » extensive facility characterization tests were already conducted. The transient system behavior tests are underway; preliminary results from the first transient test M3 are reviewed.« less

  9. Performance analysis and an assessment of operational issues of Ya-21U

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paramonov, D.V.; El-Genk, M.S.

    1996-03-01

    Extensive testing of the Soviet made TOPAZ-II space nuclear power system unit designated {open_quote}{open_quote}Ya-21U{close_quote}{close_quote} was conducted both in the USSR (1989{endash}1990) and in the US (August 1993 to March 1995). The unit underwent a total of 15 tests for a cumulative test/operation time of almost 8000 hours. These tests included steady-state operation at different power levels, fast startups and power optimizations. Leaks were detected in some of the Thermionic Fuel Elements (TFEs) after the first test in the US. These leaks that facilitated air incursion into the interelectrode gap caused operational changes in both electric power and conversion efficiency andmore » changed the optimum cesium pressure and load voltage. Additional changes in operational performance were detected following shock and vibration tests performed in August 1994. Test data was examined and analyzed to assess the performance of not only individual TFEs, and also the whole Ya-21U unit, and identify causes for measured operational performance changes; most probable causes were identified and discussed. The Ya-21U unit remained operational throughout extensive testing for 8000 hours at conditions far exceeding the design limits of the TOPAZ-II system. No single TFE was damaged during testing and measured operational performance changes were uniform among working section TFEs. In addition to providing a unique knowledge base for future development and operation of thermionic power systems, the test results testify to the reliability and ruggedness of the TOPAZ-II system design. {copyright} {ital 1996 American Institute of Physics.}« less

  10. 41 CFR 300-90.8 - What must we do to apply for a test program extension?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 41 Public Contracts and Property Management 4 2014-07-01 2014-07-01 false What must we do to apply for a test program extension? 300-90.8 Section 300-90.8 Public Contracts and Property Management Federal Travel Regulation System GENERAL AGENCY REQUIREMENTS 90-TELEWORK TRAVEL EXPENSES TEST PROGRAMS...

  11. The Clawpack Community of Codes

    NASA Astrophysics Data System (ADS)

    Mandli, K. T.; LeVeque, R. J.; Ketcheson, D.; Ahmadia, A. J.

    2014-12-01

    Clawpack, the Conservation Laws Package, has long been one of the standards for solving hyperbolic conservation laws but over the years has extended well beyond this role. Today a community of open-source codes have been developed that address a multitude of different needs including non-conservative balance laws, high-order accurate methods, and parallelism while remaining extensible and easy to use, largely by the judicious use of Python and the original Fortran codes that it wraps. This talk will present some of the recent developments in projects under the Clawpack umbrella, notably the GeoClaw and PyClaw projects. GeoClaw was originally developed as a tool for simulating tsunamis using adaptive mesh refinement but has since encompassed a large number of other geophysically relevant flows including storm surge and debris-flows. PyClaw originated as a Python version of the original Clawpack algorithms but has since been both a testing ground for new algorithmic advances in the Clawpack framework but also an easily extensible framework for solving hyperbolic balance laws. Some of these extensions include the addition of WENO high-order methods, massively parallel capabilities, and adaptive mesh refinement technologies, made possible largely by the flexibility of the Python language and community libraries such as NumPy and PETSc. Because of the tight integration with Python tecnologies, both packages have benefited also from the focus on reproducibility in the Python community, notably IPython notebooks.

  12. Extensively Drug-resistant Tuberculosis (XDR-TB): A daunting challenge to the current End TB Strategy and policy recommendations.

    PubMed

    Rahman, Md Arifur; Sarkar, Atanu

    2017-07-01

    Extensively Drug-resistant Tuberculosis (XDR-TB) has emerged as one of the most formidable challenges to the End TB Strategy that has targeted a 95% reduction in TB deaths and 90% reduction in cases by 2035. Globally, there were an estimated 55,100 new XDR-TB cases in 2015 in 117 countries. However, only one in 30 XDR-TB cases had been reported so far. Drug susceptibility test (DST) is the mainstay for diagnosing XDR-TB, but the lack of laboratory facilities in the resource-limited endemic countries limit its uses. A few new drugs including bedaquiline and delamanid, have the potential to improve the efficiency of XDR-TB treatment, but the drugs have been included in 39 countries only. The costs of XDR-TB treatment are several folds higher than that of the MDR-TB. Despite the financing from the donors, there is an urgent need to fill the current funding gap of US$ 2 billion to ensure effective treatment and robust surveillance. In the review article we have addressed current update on XDR-TB, including surveillance, diagnosis and the interventions needed to treat and limit its spread, emphasis on extensive financial support for implementing of current recommendations to meet the goals of End TB Strategy. Copyright © 2017 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  13. Application of Contact Mode AFM to Manufacturing Processes

    NASA Astrophysics Data System (ADS)

    Giordano, Michael A.; Schmid, Steven R.

    A review of the application of contact mode atomic force microscopy (AFM) to manufacturing processes is presented. A brief introduction to common experimental techniques including hardness, scratch, and wear testing is presented, with a discussion of challenges in the extension of manufacturing scale investigations to the AFM. Differences between the macro- and nanoscales tests are discussed, including indentation size effects and their importance in the simulation of processes such as grinding. The basics of lubrication theory are presented and friction force microscopy is introduced as a method of investigating metal forming lubrication on the nano- and microscales that directly simulates tooling/workpiece asperity interactions. These concepts are followed by a discussion of their application to macroscale industrial manufacturing processes and direct correlations are made.

  14. Arsenic waste management: a critical review of testing and disposal of arsenic-bearing solid wastes generated during arsenic removal from drinking water.

    PubMed

    Clancy, Tara M; Hayes, Kim F; Raskin, Lutgarde

    2013-10-01

    Water treatment technologies for arsenic removal from groundwater have been extensively studied due to widespread arsenic contamination of drinking water sources. Central to the successful application of arsenic water treatment systems is the consideration of appropriate disposal methods for arsenic-bearing wastes generated during treatment. However, specific recommendations for arsenic waste disposal are often lacking or mentioned as an area for future research and the proper disposal and stabilization of arsenic-bearing waste remains a barrier to the successful implementation of arsenic removal technologies. This review summarizes current disposal options for arsenic-bearing wastes, including landfilling, stabilization, cow dung mixing, passive aeration, pond disposal, and soil disposal. The findings from studies that simulate these disposal conditions are included and compared to results from shorter, regulatory tests. In many instances, short-term leaching tests do not adequately address the range of conditions encountered in disposal environments. Future research directions are highlighted and include establishing regulatory test conditions that align with actual disposal conditions and evaluating nonlandfill disposal options for developing countries.

  15. Conference on abuse liability and appeal of tobacco products: conclusions and recommendations.

    PubMed

    Henningfield, Jack E; Hatsukami, Dorothy K; Zeller, Mitch; Peters, Ellen

    2011-07-01

    The rate of initiation and progression to dependence and premature mortality are higher for tobacco products than for any other dependence producing substance. This is not explained simply by the addictiveness ("abuse liability") or by enticing product designs ("product appeal") alone, but rather by both of these factors in combination with marketing and social influences that also influence "product appeal". A working meeting of leading experts in abuse liability (AL) and product appeal was convened to examine how these disciplines could be more effectively applied to the evaluation of tobacco products for the purposes of regulation that would include setting standards for designs and contents intended to reduce the risk of initiation and dependence. It was concluded that abuse liability assessment (ALA) is a validated approach to testing pharmaceutical products but has not been extensively applied to tobacco products: such application has demonstrated feasibility, but special challenges include the diverse range of products, product complexity, and the absence of satisfactory placebo products. Consumer testing for product appeal is widely used by consumer product marketers as well as by researchers in their efforts to understand consumer product preferences and use but has not been extensively applied to tobacco products except by the tobacco industry. Recommendations for testing, methods development, and research were developed. A major recommendation was that tobacco products should be tested for AL and product appeal, and the results integrated and evaluated so as to more accurately predict risk of initiation, dependence, and persistence of use. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  16. Conference on Abuse Liability and Appeal of Tobacco Products: Conclusions and Recommendations*

    PubMed Central

    Hatsukami, Dorothy K.; Zeller, Mitch; Peters, Ellen

    2011-01-01

    The rate of initiation and progression to dependence and premature mortality are higher for tobacco products than for any other dependence producing substance. This is not explained simply by the addictiveness (“abuse liability”) or by enticing product designs (“product appeal”) alone, but rather by both of these factors in combination with marketing and social influences that also influence “product appeal”. A working meeting of leading experts in abuse liability (AL) and product appeal was convened to examine how these disciplines could be more effectively applied to the evaluation of tobacco products for the purposes of regulation that would include setting standards for designs and contents intended to reduce the risk of initiation and dependence. It was concluded that abuse liability assessment (ALA) is a validated approach to testing pharmaceutical products but has not been extensively applied to tobacco products: such application has demonstrated feasibility, but special challenges include the diverse range of products, product complexity, and the absence of satisfactory placebo products. Consumer testing for product appeal is widely used by consumer products marketers as well as by researchers in their efforts to understand consumer product preferences and use but has not been extensively applied to tobacco products except by the tobacco industry. Recommendations for testing, methods development, and research were developed. A major recommendation was that tobacco products should be tested for AL and product appeal, and the results integrated and evaluated so as to more accurately predict risk of initiation, dependence, and persistence of use. PMID:21376479

  17. Overview of free-piston Stirling technology at the NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Slaby, J. G.

    1985-01-01

    An overview of the National Aeronautics and Space Administration (NASA) Lewis Research Center (Lewis) free-piston Stirling engine activities is presented. These activities include: (1) a generic free-piston Stirling technology project being conducted to develop technologies synergistic to both space power and terrestrial heat pump applications in a cooperative, cost-shared effort with the Department of Energy (DOE/Oak Ridge National Laboratory (ONRL)), and (2) a free-piston Stirling space-power technology demonstration project as part of the SP-100 program being conducted in support of the Department of Defense (DOD), DOE, and NASA/Lewis. The generic technology effort includes extensive parametric testing of a 1 kw free-piston Stirling engine (RE-1000), development and validation of a free-piston Stirling performance computer code, and fabrication and initial testing of an hydraulic output modification for the RE-1000 engine. The space power technology effort, under SP-100, addresses the status of the 25 kWe Space Power Demonstrator Engine (SPDE) including early test results.

  18. Aerodynamics of an Axisymmetric Missile Concept Having Cruciform Strakes and In-Line Tail Fins From Mach 0.60 to 4.63

    NASA Technical Reports Server (NTRS)

    Allen, Jerry M.

    2005-01-01

    An experimental study has been performed to develop a large force and moment aerodynamic data set on a slender axisymmetric missile configuration having cruciform strakes and in-line control tail fins. The data include six-component balance measurements of the configuration aerodynamics and three-component measurements on all four tail fins. The test variables include angle of attack, roll angle, Mach number, model buildup, strake length, nose size, and tail fin deflection angles to provide pitch, yaw, and roll control. Test Mach numbers ranged from 0.60 to 4.63. The entire data set is presented on a CD-ROM that is attached to this paper. The CD-ROM also includes extensive plots of both the six-component configuration data and the three-component tail fin data. Selected samples of these plots are presented in this paper to illustrate the features of the data and to investigate the effects of the test variables.

  19. Aerodynamics of an Axisymmetric Missile Concept Having Cruciform Strakes and In-Line Tail Fins From Mach 0.60 to 4.63, Supplement

    NASA Technical Reports Server (NTRS)

    Allen, Jerry M.

    2005-01-01

    An experimental study has been performed to develop a large force and moment aerodynamic data set on a slender axisymmetric missile configuration having cruciform strakes and in-line control tail fins. The data include six-component balance measurements of the configuration aerodynamics and three-component measurements on all four tail fins. The test variables include angle of attack, roll angle, Mach number, model buildup, strake length, nose size, and tail fin deflection angles to provide pitch, yaw, and roll control. Test Mach numbers ranged from 0.60 to 4.63. The entire data set is presented on a CD-ROM that is attached to this paper. The CD-ROM also includes extensive plots of both the six-component configuration data and the three-component tail fin data. Selected samples of these plots are presented in this paper to illustrate the features of the data and to investigate the effects of the test variables.

  20. Is procrastination a vulnerability factor for hypertension and cardiovascular disease? Testing an extension of the procrastination-health model.

    PubMed

    Sirois, Fuschia M

    2015-06-01

    Personality is an important epidemiological factor for understanding health outcomes. This study investigated the associations of trait procrastination with hypertension and cardiovascular disease (HT/CVD) and maladaptive coping by testing an extension of the procrastination-health model among individuals with and without HT/CVD. Individuals with self-reported HT/CVD (N = 182) and healthy controls (N = 564), from a community sample, completed an online survey including measures of personality, coping, and health outcomes. Logistic regression analysis controlling for demographic and higher order personality factors found that older age, lower education level and higher procrastination scores were associated with HT/CVD. Moderated mediation analyses with bootstrapping revealed that procrastination was more strongly associated with maladaptive coping behaviours in participants with HT/CVD than the healthy controls, and the indirect effects on stress through maladaptive coping were larger for the HT/CVD sample. Results suggest procrastination is a vulnerability factor for poor adjustment to and management of HT/CVD.

  1. Hybrid Teaching in Extension: Learning at the Crossroads

    ERIC Educational Resources Information Center

    Hino, Jeff; Kahn, Cub

    2016-01-01

    Extension clients' learning preferences are changing, with many increasingly going online for educational content. In response, Oregon State University Extension pilot tested a training program for Extension educators to explore hybrid teaching--a methodology that could provide more flexible access to a wider audience. Hybrid teaching offers a…

  2. Capabilities, Design, Construction and Commissioning of New Vibration, Acoustic, and Electromagnetic Capabilities Added to the World's Largest Thermal Vacuum Chamber at NASA's Space Power Facility

    NASA Technical Reports Server (NTRS)

    Motil, Susan M.; Ludwiczak, Damian R.; Carek, Gerald A.; Sorge, Richard N.; Free, James M.; Cikanek, Harry A., III

    2011-01-01

    NASA s human space exploration plans developed under the Exploration System Architecture Studies in 2005 included a Crew Exploration Vehicle launched on an Ares I launch vehicle. The mass of the Crew Exploration Vehicle and trajectory of the Ares I coupled with the need to be able to abort across a large percentage of the trajectory generated unprecedented testing requirements. A future lunar lander added to projected test requirements. In 2006, the basic test plan for Orion was developed. It included several types of environment tests typical of spacecraft development programs. These included thermal-vacuum, electromagnetic interference, mechanical vibration, and acoustic tests. Because of the size of the vehicle and unprecedented acoustics, NASA conducted an extensive assessment of options for testing, and as result, chose to augment the Space Power Facility at NASA Plum Brook Station, of the John H. Glenn Research Center to provide the needed test capabilities. The augmentation included designing and building the World s highest mass capable vibration table, the highest power large acoustic chamber, and adaptation of the existing World s largest thermal vacuum chamber as a reverberant electromagnetic interference test chamber. These augmentations were accomplished from 2007 through early 2011. Acceptance testing began in Spring 2011 and will be completed in the Fall of 2011. This paper provides an overview of the capabilities, design, construction and acceptance of this extraordinary facility.

  3. Tests of local Lorentz invariance violation of gravity in the standard model extension with pulsars.

    PubMed

    Shao, Lijing

    2014-03-21

    The standard model extension is an effective field theory introducing all possible Lorentz-violating (LV) operators to the standard model and general relativity (GR). In the pure-gravity sector of minimal standard model extension, nine coefficients describe dominant observable deviations from GR. We systematically implemented 27 tests from 13 pulsar systems to tightly constrain eight linear combinations of these coefficients with extensive Monte Carlo simulations. It constitutes the first detailed and systematic test of the pure-gravity sector of minimal standard model extension with the state-of-the-art pulsar observations. No deviation from GR was detected. The limits of LV coefficients are expressed in the canonical Sun-centered celestial-equatorial frame for the convenience of further studies. They are all improved by significant factors of tens to hundreds with existing ones. As a consequence, Einstein's equivalence principle is verified substantially further by pulsar experiments in terms of local Lorentz invariance in gravity.

  4. Surface energy fluxes in complex terrain

    NASA Technical Reports Server (NTRS)

    Reiter, E. R.; Sheaffer, J. D.; Bossert, J. E.

    1986-01-01

    The emphasis of the 1985 NASA project activity was on field measurements of wind data and heat balance data. Initiatives included a 19 station mountaintop monitoring program, testing and refining the surface flux monitoring systems and packing and shipping equipment to the People's Republic of China in preparation for the 1986 Tibet Experiment. Other work included more extensive analyses of the 1984 Gobi Desert and Rocky Mountain observations plus some preliminary analyses of the 1985 mountaintop network data. Details of our field efforts are summarized and results of our data analyses are presented.

  5. Analysis of advanced solid rocket motor ignition phenomena

    NASA Technical Reports Server (NTRS)

    Foster, Winfred A., Jr.; Jenkins, Rhonald M.

    1995-01-01

    This report presents the results obtained from an experimental analysis of the flow field in the slots of the star grain section in the head-end of the advanced solid rocket motor during the ignition transient. This work represents an extension of the previous tests and analysis to include the effects of using a center port in conjunction with multiple canted igniter ports. The flow field measurements include oil smear data on the star slot walls, pressure and heat transfer coefficient measurements on the star slot walls and velocity measurements in the star slot.

  6. Strain Measurement System Developed for Biaxially Loaded Cruciform Specimens

    NASA Technical Reports Server (NTRS)

    Krause, David L.

    2000-01-01

    A new extensometer system developed at the NASA Glenn Research Center at Lewis Field measures test area strains along two orthogonal axes in flat cruciform specimens. This system incorporates standard axial contact extensometers to provide a cost-effective high-precision instrument. The device was validated for use by extensive testing of a stainless steel specimen, with specimen temperatures ranging from room temperature to 1100 F. In-plane loading conditions included several static biaxial load ratios, plus cyclic loadings of various waveform shapes, frequencies, magnitudes, and durations. The extensometer system measurements were compared with strain gauge data at room temperature and with calculated strain values for elevated-temperature measurements. All testing was performed in house in Glenn's Benchmark Test Facility in-plane biaxial load frame.

  7. Advanced thermoplastic resins, phase 1

    NASA Technical Reports Server (NTRS)

    Hendricks, C. L.; Hill, S. G.; Falcone, A.; Gerken, N. T.

    1991-01-01

    Eight thermoplastic polyimide resin systems were evaluated as composite matrix materials. Two resins were selected for more extensive mechanical testing and both were versions of LaRC-TPI (Langley Research Center - Thermoplastic Polyimide). One resin was made with LaRC-TPI and contained 2 weight percent of a di(amic acid) dopant as a melt flow aid. The second system was a 1:1 slurry of semicrystalline LaRC-TPI powder in a polyimidesulfone resin diglyme solution. The LaRC-TPI powder melts during processing and increases the melt flow of the resin. Testing included dynamic mechanical analysis, tension and compression testing, and compression-after-impact testing. The test results demonstrated that the LaRC-TPI resins have very good properties compared to other thermoplastics, and that they are promising matrix materials for advanced composite structures.

  8. Turbine gas temperature measurement and control system

    NASA Technical Reports Server (NTRS)

    Webb, W. L.

    1973-01-01

    A fluidic Turbine Inlet Gas Temperature (TIGIT) Measurement and Control System was developed for use on a Pratt and Whitney Aircraft J58 engine. Based on engine operating requirements, criteria for high temperature materials selection, system design, and system performance were established. To minimize development and operational risk, the TIGT control system was designed to interface with an existing Exhaust Gas Temperature (EGT) Trim System and thereby modulate steady-state fuel flow to maintain a desired TIGT level. Extensive component and system testing was conducted including heated (2300F) vibration tests for the fluidic sensor and gas sampling probe, temperature and vibration tests on the system electronics, burner rig testing of the TIGT measurement system, and in excess of 100 hours of system testing on a J58 engine. (Modified author abstract)

  9. Adjacent-Level Hypermobility and Instrumented-Level Fatigue Loosening With Titanium and PEEK Rods for a Pedicle Screw System: An In Vitro Study.

    PubMed

    Agarwal, Aakas; Ingels, Marcel; Kodigudla, Manoj; Momeni, Narjes; Goel, Vijay; Agarwal, Anand K

    2016-05-01

    Adjacent-level disease is a common iatrogenic complication seen among patients undergoing spinal fusion for low back pain. This is attributed to the postsurgical differences in stiffness between the spinal levels, which result in abnormal forces, stress shielding, and hypermobility at the adjacent levels. In addition, as most patients undergoing these surgeries are osteoporotic, screw loosening at the index level is a complication that commonly accompanies adjacent-level disease. Recent studies indicate that a rod with lower rigidity than that of titanium may help to overcome these detrimental effects at the adjacent level. The present study was conducted in vitro using 12 L1-S1 specimens divided into groups of six, with each group instrumented with either titanium rods or PEEK (polyetheretherketone) rods. The test protocol included subjecting intact specimens to pure moments of 10 Nm in extension and flexion using an FS20 Biomechanical Spine Test System (Applied Test Systems) followed by hybrid moments on the instrumented specimens to achieve the same L1-S1 motion as that of the intact specimens. During the protocol's later phase, the L4-L5 units from each specimen were segmented for cyclic loading followed by postfatigue kinematic analysis to highlight the differences in motion pre- and postfatigue. The objectives included the in vitro comparison of (1) the adjacent-level motion before and after instrumentation with PEEK and titanium rods and (2) the pre- and postfatigue motion at the instrumented level with PEEK and titanium rods. The results showed that the adjacent levels above the instrumentation caused increased flexion and extension with both PEEK and titanium rods. The postfatigue kinematic data showed that the motion at the instrumented level (L4-L5) increased significantly in both flexion and extension compared to prefatigue motion in titanium groups. However, there was no significant difference in motion between the pre- and postfatigue data in the PEEK group.

  10. Development and validation of a high density SNP genotyping array for Atlantic salmon (Salmo salar).

    PubMed

    Houston, Ross D; Taggart, John B; Cézard, Timothé; Bekaert, Michaël; Lowe, Natalie R; Downing, Alison; Talbot, Richard; Bishop, Stephen C; Archibald, Alan L; Bron, James E; Penman, David J; Davassi, Alessandro; Brew, Fiona; Tinch, Alan E; Gharbi, Karim; Hamilton, Alastair

    2014-02-06

    Dense single nucleotide polymorphism (SNP) genotyping arrays provide extensive information on polymorphic variation across the genome of species of interest. Such information can be used in studies of the genetic architecture of quantitative traits and to improve the accuracy of selection in breeding programs. In Atlantic salmon (Salmo salar), these goals are currently hampered by the lack of a high-density SNP genotyping platform. Therefore, the aim of the study was to develop and test a dense Atlantic salmon SNP array. SNP discovery was performed using extensive deep sequencing of Reduced Representation (RR-Seq), Restriction site-Associated DNA (RAD-Seq) and mRNA (RNA-Seq) libraries derived from farmed and wild Atlantic salmon samples (n = 283) resulting in the discovery of > 400 K putative SNPs. An Affymetrix Axiom® myDesign Custom Array was created and tested on samples of animals of wild and farmed origin (n = 96) revealing a total of 132,033 polymorphic SNPs with high call rate, good cluster separation on the array and stable Mendelian inheritance in our sample. At least 38% of these SNPs are from transcribed genomic regions and therefore more likely to include functional variants. Linkage analysis utilising the lack of male recombination in salmonids allowed the mapping of 40,214 SNPs distributed across all 29 pairs of chromosomes, highlighting the extensive genome-wide coverage of the SNPs. An identity-by-state clustering analysis revealed that the array can clearly distinguish between fish of different origins, within and between farmed and wild populations. Finally, Y-chromosome-specific probes included on the array provide an accurate molecular genetic test for sex. This manuscript describes the first high-density SNP genotyping array for Atlantic salmon. This array will be publicly available and is likely to be used as a platform for high-resolution genetics research into traits of evolutionary and economic importance in salmonids and in aquaculture breeding programs via genomic selection.

  11. Development and validation of a high density SNP genotyping array for Atlantic salmon (Salmo salar)

    PubMed Central

    2014-01-01

    Background Dense single nucleotide polymorphism (SNP) genotyping arrays provide extensive information on polymorphic variation across the genome of species of interest. Such information can be used in studies of the genetic architecture of quantitative traits and to improve the accuracy of selection in breeding programs. In Atlantic salmon (Salmo salar), these goals are currently hampered by the lack of a high-density SNP genotyping platform. Therefore, the aim of the study was to develop and test a dense Atlantic salmon SNP array. Results SNP discovery was performed using extensive deep sequencing of Reduced Representation (RR-Seq), Restriction site-Associated DNA (RAD-Seq) and mRNA (RNA-Seq) libraries derived from farmed and wild Atlantic salmon samples (n = 283) resulting in the discovery of > 400 K putative SNPs. An Affymetrix Axiom® myDesign Custom Array was created and tested on samples of animals of wild and farmed origin (n = 96) revealing a total of 132,033 polymorphic SNPs with high call rate, good cluster separation on the array and stable Mendelian inheritance in our sample. At least 38% of these SNPs are from transcribed genomic regions and therefore more likely to include functional variants. Linkage analysis utilising the lack of male recombination in salmonids allowed the mapping of 40,214 SNPs distributed across all 29 pairs of chromosomes, highlighting the extensive genome-wide coverage of the SNPs. An identity-by-state clustering analysis revealed that the array can clearly distinguish between fish of different origins, within and between farmed and wild populations. Finally, Y-chromosome-specific probes included on the array provide an accurate molecular genetic test for sex. Conclusions This manuscript describes the first high-density SNP genotyping array for Atlantic salmon. This array will be publicly available and is likely to be used as a platform for high-resolution genetics research into traits of evolutionary and economic importance in salmonids and in aquaculture breeding programs via genomic selection. PMID:24524230

  12. Synergistic Development, Test, and Qualification Approaches for the Ares I and V Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Cockrell, Charles E.; Taylor, James L.; Patterson, Alan; Stephens, Samuel E.; Tuma, Margaret; Bartolotta, Paul; Huetter, Uwe; Kaderback, Don; Goggin, David

    2009-01-01

    The U.S. National Aeronautics and Space Administration (NASA) initiated plans to develop the Ares I and Ares V launch vehicles in 2005 to meet the mission objectives for future human exploration of space. Ares I is designed to provide the capability to deliver the Orion crew exploration vehicle (CEV) to low-Earth orbit (LEO), either for docking to the International Space Station (ISS) or docking with an Earth departure stage (EDS) and lunar lander for transit to the Moon. Ares V provides the heavy-lift capability to deliver the EDS and lunar lander to orbit. An integrated test plan was developed for Ares I that includes un-crewed flight validation testing and ground testing to qualify structural components and propulsion systems prior to operational deployment. The overall test program also includes a single development test flight conducted prior to the Ares I critical design review (CDR). Since the Ares V concept was formulated to maximize hardware commonality between the Ares V and Ares I launch vehicles, initial test planning for Ares V has considered the extensibility of test approaches and facilities from Ares I. The Ares V test plan was part of a successful mission concept review (MCR) in 2008.

  13. Test Cases for the Benchmark Active Controls: Spoiler and Control Surface Oscillations and Flutter

    NASA Technical Reports Server (NTRS)

    Bennett, Robert M.; Scott, Robert C.; Wieseman, Carol D.

    2000-01-01

    As a portion of the Benchmark Models Program at NASA Langley, a simple generic model was developed for active controls research and was called BACT for Benchmark Active Controls Technology model. This model was based on the previously-tested Benchmark Models rectangular wing with the NACA 0012 airfoil section that was mounted on the Pitch and Plunge Apparatus (PAPA) for flutter testing. The BACT model had an upper surface spoiler, a lower surface spoiler, and a trailing edge control surface for use in flutter suppression and dynamic response excitation. Previous experience with flutter suppression indicated a need for measured control surface aerodynamics for accurate control law design. Three different types of flutter instability boundaries had also been determined for the NACA 0012/PAPA model, a classical flutter boundary, a transonic stall flutter boundary at angle of attack, and a plunge instability near M = 0.9. Therefore an extensive set of steady and control surface oscillation data was generated spanning the range of the three types of instabilities. This information was subsequently used to design control laws to suppress each flutter instability. There have been three tests of the BACT model. The objective of the first test, TDT Test 485, was to generate a data set of steady and unsteady control surface effectiveness data, and to determine the open loop dynamic characteristics of the control systems including the actuators. Unsteady pressures, loads, and transfer functions were measured. The other two tests, TDT Test 502 and TDT Test 5 18, were primarily oriented towards active controls research, but some data supplementary to the first test were obtained. Dynamic response of the flexible system to control surface excitation and open loop flutter characteristics were determined during Test 502. Loads were not measured during the last two tests. During these tests, a database of over 3000 data sets was obtained. A reasonably extensive subset of the data sets from the first two tests have been chosen for Test Cases for computational comparisons concentrating on static conditions and cases with harmonically oscillating control surfaces. Several flutter Test Cases from both tests have also been included. Some aerodynamic comparisons with the BACT data have been made using computational fluid dynamics codes at the Navier-Stokes level (and in the accompanying chapter SC). Some mechanical and active control studies have been presented. In this report several Test Cases are selected to illustrate trends for a variety of different conditions with emphasis on transonic flow effects. Cases for static angles of attack, static trailing-edge and upper-surface spoiler deflections are included for a range of conditions near those for the oscillation cases. Cases for trailing-edge control and upper-surface spoiler oscillations for a range of Mach numbers, angle of attack, and static control deflections are included. Cases for all three types of flutter instability are selected. In addition some cases are included for dynamic response measurements during forced oscillations of the controls on the flexible mount. An overview of the model and tests is given, and the standard formulary for these data is listed. Some sample data and sample results of calculations are presented. Only the static pressures and the first harmonic real and imaginary parts of the pressures are included in the data for the Test Cases, but digitized time histories have been archived. The data for the Test Cases are also available as separate electronic files.

  14. Space shuttle phase B wind tunnel model and test information. Volume 1: Booster configuration

    NASA Technical Reports Server (NTRS)

    Glynn, J. L.; Poucher, D. E.

    1988-01-01

    Archived wind tunnel test data are available for flyback booster or other alternative recoverable configurations as well as reusable orbiters studied during initial development (Phase B) of the Space Shuttle. Considerable wind tunnel data was acquired by the competing contractors and the NASA Centers for an extensive variety of configurations with an array of wing and body planforms. All contractor and NASA wind tunnel test data acquired in the Phase B development have been compiled into a database and are available for application to current winged flyback or recoverable booster aerodynamic studies. The Space Shuttle Phase B Wind Tunnel Database is structured by vehicle component and configuration type. Basic components include the booster, the orbiter, and the launch vehicle. Booster configuration types include straight and delta wings, canard, cylindrical, retroglide and twin body. Orbiter configuration types include straight and delta wings, lifting body, drop tanks and double delta wings. Launch configurations include booster and orbiter components in various stacked and tandem combinations. This is Volume 1 (Part 2) of the report -- Booster Configuration.

  15. Space shuttle phase B wind tunnel model and test information. Volume 1: Booster configuration

    NASA Technical Reports Server (NTRS)

    Glynn, J. L.; Poucher, D. E.

    1988-01-01

    Archived wind tunnel test data are available for flyback booster or other alternative recoverable configurations as well as reusable orbiters studied during initial development (Phase B) of the Space Shuttle. Considerable wind tunnel data was acquired by the competing contractors and the NASA Centers for an extensive variety of configurations with an array of wing and body planforms. All contractor and NASA wind tunnel test data acquired in the Phase B development have been compiled into a database and are available for application to current winged flyback or recoverable booster aerodynamic studies. The Space Shuttle Phase B Wind Tunnel Database is structured by vehicle component and configuration type. Basic components include the booster, the orbiter and the launch vehicle. Booster configuration types include straight and delta wings, canard, cylindrical, retroglide and twin body. Orbiter configuration types include straight and delta wings, lifting body, drop tanks, and double delta wings. Launch configurations include booster and orbiter components in various stacked and tandem combinations. This is Volume 1 (Part 1) of the report -- Booster Configuration.

  16. The next generation in aircraft protection against advanced MANPADS

    NASA Astrophysics Data System (ADS)

    Chapman, Stuart

    2014-10-01

    This paper discusses the advanced and novel technologies and underlying systems capabilities that Selex ES has applied during the development, test and evaluation of the twin head Miysis DIRCM System in order to ensure that it provides the requisite levels of protection against the latest, sophisticated all-aspect IR MANPADS. The importance of key performance parameters, including the fundamental need for "spherical" coverage, rapid time to energy-on-target, laser tracking performance and radiant intensity on seeker dome is covered. It also addresses the approach necessary to ensure that the equipment is suited to all air platforms from the smallest helicopters to large transports, while also ensuring that it achieves an inherent high reliability and an ease of manufacture and repair such that a step change in through-life cost in comparison to previous generation systems can be achieved. The benefits and issues associated with open architecture design are also considered. Finally, the need for extensive test and evaluation at every stage, including simulation, laboratory testing, platform and target dynamic testing in a System Integration Laboratory (SIL), flight trial, missile live-fire, environmental testing and reliability testing is also described.

  17. Reconfiguration of NASA GRC's Vacuum Facility 6 for Testing of Advanced Electric Propulsion System (AEPS) Hardware

    NASA Technical Reports Server (NTRS)

    Peterson, Peter; Kamhawi, Hani; Huang, Wensheng; Yim, John; Haag, Tom; Mackey, Jonathan; McVetta, Mike; Sorrelle, Luke; Tomsik, Tom; Gilligan, Ryan; hide

    2016-01-01

    The NASA Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kilowatt Hall thruster has been the subject of extensive technology maturation in preparation for development into a flight propulsion system. The HERMeS thruster is being developed and tested at NASA GRC and NASA JPL through support of the Space Technology Mission Directorate and is intended to be used as the electric propulsion system on the Power and Propulsion Element of the recently announced Deep Space Gateway. The Advanced Electric Propulsion System (AEPS) contract was awarded to Aerojet Rocketdyne to develop the HERMeS system into a flight system for use by NASA. To address the hardware test needs of the AEPS project, NASA GRC launched an effort to reconfigure Vacuum Facility 6 for high-power electric propulsion testing including upgrades and reconfigurations necessary to conduct performance, plasma plume, and system level integration testing. Results of the verification and validation testing with HERMeS Technology Demonstration Unit (TDU) 1 and TDU-3 Hall thrusters are also included.

  18. Reconfiguration of NASA GRC's Vacuum Facility 6 for Testing of Advanced Electric Propulsion System (AEPS) Hardware

    NASA Technical Reports Server (NTRS)

    Peterson, Peter Y.; Kamhawi, Hani; Huang, Wensheng; Yim, John; Haag, Tom; Mackey, Jonathan; McVetta, Mike; Sorrelle, Luke; Tomsik, Tom; Gilligan, Ryan; hide

    2017-01-01

    The NASA Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kilowatt Hall thruster has been the subject of extensive technology maturation in preparation for development into a flight propulsion system. The HERMeS thruster is being developed and tested at NASA GRC and NASA JPL through support of the Space Technology Mission Directorate and is intended to be used as the electric propulsion system on the Power and Propulsion Element of the recently announced Deep Space Gateway. The Advanced Electric Propulsion System (AEPS) contract was awarded to Aerojet Rocketdyne to develop the HERMeS system into a flight system for use by NASA. To address the hardware test needs of the AEPS project, NASA GRC launched an effort to reconfigure Vacuum Facility 6 for high-power electric propulsion testing including upgrades and reconfigurations necessary to conduct performance, plasma plume, and system level integration testing. Results of the verification and validation testing with HERMeS Technology Demonstration Unit (TDU) 1 and TDU-3 Hall thrusters are also included.

  19. Reconfiguration of NASA GRC's Vacuum Facility 6 for Testing of Advanced Electric Propulsion System (AEPS) Hardware

    NASA Technical Reports Server (NTRS)

    Peterson, Peter Y.; Kamhawi, Hani; Huang, Wensheng; Yim, John T.; Haag, Thomas W.; Mackey, Jonathan A.; McVetta, Michael S.; Sorrelle, Luke T.; Tomsik, Thomas M.; Gilligan, Ryan P.; hide

    2018-01-01

    The NASA Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Hall thruster has been the subject of extensive technology maturation in preparation for development into a flight propulsion system. The HERMeS thruster is being developed and tested at NASA GRC and NASA JPL through support of the Space Technology Mission Directorate (STMD) and is intended to be used as the electric propulsion system on the Power and Propulsion Element (PPE) of the recently announced Deep Space Gateway (DSG). The Advanced Electric Propulsion System (AEPS) contract was awarded to Aerojet-Rocketdyne to develop the HERMeS system into a flight system for use by NASA. To address the hardware test needs of the AEPS project, NASA GRC launched an effort to reconfigure Vacuum Facility 6 (VF-6) for high-power electric propulsion testing including upgrades and reconfigurations necessary to conduct performance, plasma plume, and system level integration testing. Results of the verification and validation testing with HERMeS Technology Demonstration Unit (TDU)-1 and TDU-3 Hall thrusters are also included.

  20. Gas turbine critical research and advanced technology (CRT) support project

    NASA Technical Reports Server (NTRS)

    Furman, E. R.; Anderson, D. N.; Gedwill, M. A.; Lowell, C. E.; Schultz, D. F.

    1982-01-01

    The technical progress to provide a critical technology base for utility gas turbine systems capable of burning coal-derived fuels is summarized. Project tasks include the following: (1) combustion - to investigate the combustion of coal-derived fuels and the conversion of fuel-bound nitrogen to NOx; (2) materials - to understand and prevent the hot corrosion of turbine hot section materials; and (3) system studies - to integrate and guide the technological efforts. Technical accomplishments include: an extension of flame tube combustion testing of propane - Toluene Fuel Mixtures to vary H2 content from 9 to 18 percent by weight and the comparison of results with that predicted from a NASA Lewis General Chemical Kinetics Computer Code; the design and fabrication of combustor sector test section to test current and advanced combustor concepts; Testing of Catalytic combustors with residual and coal-derived liquid fuels; testing of high strength super alloys to evaluate their resistance to potential fuel impurities using doped clean fuels and coal-derived liquids; and the testing and evaluation of thermal barrier coatings and bond coatings on conventional turbine materials.

  1. Functional Performance Testing After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Abrams, Geoffrey D.; Harris, Joshua D.; Gupta, Anil K.; McCormick, Frank M.; Bush-Joseph, Charles A.; Verma, Nikhil N.; Cole, Brian J.; Bach, Bernard R.

    2014-01-01

    Background: When to allow an athlete to return to unrestricted sporting activity after anterior cruciate ligament (ACL) reconstruction remains controversial. Purpose: To report the results of functional performance testing reported in the literature for individuals at differing time points following ACL reconstruction and to examine differences between graft types. Study Design: Systematic review; Level of evidence, 4. Methods: A systematic review of Medline, Scopus, and Cochrane Central Register of Controlled Trials was performed using PRISMA guidelines. Inclusion criteria were English-language studies that examined any functional rehabilitation test from 6 months to 2 years following ACL reconstruction. All patient-, limb-, and knee-specific demographics were extracted from included investigations. All functional rehabilitation tests were analyzed and compared when applicable. Results: The search term returned a total of 890 potential studies, with 88 meeting inclusion and exclusion criteria. A total of 4927 patients were included, of which 66% were male. The mean patient age was 26.5 ± 3.4 years. The predominant graft choices for reconstruction were bone–patellar tendon–bone (BPTB) autograft (59.8%) and hamstring autograft (37.9%). The most commonly reported functional tests were the hop tests. The results of these functional tests, as reported in the Limb Symmetry Index (LSI), improved with increasing time, with nearly all results greater than 90% at 1 year following primary ACL reconstruction. At 6 months postoperatively, a number of isokinetic strength measurements failed to reach 80% LSI, most commonly isokinetic knee extension testing in both BPTB and hamstring autograft groups. The knee flexion strength deficit was significantly less in the BPTB autograft group as compared with those having hamstring autograft at 1 year postoperatively, while no significant differences were found in isokinetic extension strength between the 2 groups. Conclusion: Hop testing was the most commonly reported functional test following ACL reconstruction. Increases in performance on functional tests were predictably seen as time increased following surgery. Those with hamstring autografts may experience increased strength deficits with knee flexion versus those having BPTB autograft. These data provide information that may assist providers in determining timing of return to unrestricted sporting activity. PMID:26535266

  2. Lateral epicondylitis of the elbow.

    PubMed

    Tosti, Rick; Jennings, John; Sewards, J Milo

    2013-04-01

    Lateral epicondylitis, or "tennis elbow," is a common musculotendinous degenerative disorder of the extensor origin at the lateral humeral epicondyle. Repetitive occupational or athletic activities involving wrist extension and supination are thought to be causative. The typical symptoms include lateral elbow pain, pain with wrist extension, and weakened grip strength. The diagnosis is made clinically through history and physical examination; however, a thorough understanding of the differential diagnosis is imperative to prevent unnecessary testing and therapies. Most patients improve with nonoperative measures, such as activity modification, physical therapy, and injections. A small percentage of patients will require surgical release of the extensor carpi radialis brevis tendon. Common methods of release may be performed via percutaneous, arthroscopic, or open approaches. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Support of Multidimensional Parallelism in the OpenMP Programming Model

    NASA Technical Reports Server (NTRS)

    Jin, Hao-Qiang; Jost, Gabriele

    2003-01-01

    OpenMP is the current standard for shared-memory programming. While providing ease of parallel programming, the OpenMP programming model also has limitations which often effect the scalability of applications. Examples for these limitations are work distribution and point-to-point synchronization among threads. We propose extensions to the OpenMP programming model which allow the user to easily distribute the work in multiple dimensions and synchronize the workflow among the threads. The proposed extensions include four new constructs and the associated runtime library. They do not require changes to the source code and can be implemented based on the existing OpenMP standard. We illustrate the concept in a prototype translator and test with benchmark codes and a cloud modeling code.

  4. Sierra Nevada, California

    NASA Image and Video Library

    1994-09-30

    STS068-267-097 (30 September-11 October 1994) --- An extensive view eastward from the irrigated San Joaquin Valley in the foreground, across the Sierra Nevada (living up to its name in early October), into the desert of eastern California and Nevada (which has no snow, despite the name). Mono Lake is just visible at the left edge of the frame; Owens Valley extends southward to Owens Lake, the next valley is Panamint Valley, and then Death Valley. Las Vegas and Lake Mead are visible at the upper right of the frame. The Space Radar Laboratory 2 (SRL-2) obtained extensive, multiple-pass data from many test sites within the region displayed, including Mammoth Mountain ski area south of Mono Lake, and in Death Valley.

  5. Solid Rocket Booster (SRB) Flight System Integration at Its Best

    NASA Technical Reports Server (NTRS)

    Wood, T. David; Kanner, Howard S.; Freeland, Donna M.; Olson, Derek T.

    2011-01-01

    The Solid Rocket Booster (SRB) element integrates all the subsystems needed for ascent flight, entry, and recovery of the combined Booster and Motor system. These include the structures, avionics, thrust vector control, pyrotechnic, range safety, deceleration, thermal protection, and retrieval systems. This represents the only human-rated, recoverable and refurbishable solid rocket ever developed and flown. Challenges included subsystem integration, thermal environments and severe loads (including water impact), sometimes resulting in hardware attrition. Several of the subsystems evolved during the program through design changes. These included the thermal protection system, range safety system, parachute/recovery system, and others. Because the system was recovered, the SRB was ideal for data and imagery acquisition, which proved essential for understanding loads, environments and system response. The three main parachutes that lower the SRBs to the ocean are the largest parachutes ever designed, and the SRBs are the largest structures ever to be lowered by parachutes. SRB recovery from the ocean was a unique process and represented a significant operational challenge; requiring personnel, facilities, transportation, and ground support equipment. The SRB element achieved reliability via extensive system testing and checkout, redundancy management, and a thorough postflight assessment process. However, the in-flight data and postflight assessment process revealed the hardware was affected much more strongly than originally anticipated. Assembly and integration of the booster subsystems required acceptance testing of reused hardware components for each build. Extensive testing was done to assure hardware functionality at each level of stage integration. Because the booster element is recoverable, subsystems were available for inspection and testing postflight, unique to the Shuttle launch vehicle. Problems were noted and corrective actions were implemented as needed. The postflight assessment process was quite detailed and a significant portion of flight operations. The SRBs provided fully redundant critical systems including thrust vector control, mission critical pyrotechnics, avionics, and parachute recovery system. The design intent was to lift off with full redundancy. On occasion, the redundancy management scheme was needed during flight operations. This paper describes some of the design challenges and technical issues, how the design evolved with time, and key areas where hardware reusability contributed to improved system level understanding.

  6. Solid Rocket Booster (SRB) - Evolution and Lessons Learned During the Shuttle Program

    NASA Technical Reports Server (NTRS)

    Kanner, Howard S.; Freeland, Donna M.; Olson, Derek T.; Wood, T. David; Vaccaro, Mark V.

    2011-01-01

    The Solid Rocket Booster (SRB) element integrates all the subsystems needed for ascent flight, entry, and recovery of the combined Booster and Motor system. These include the structures, avionics, thrust vector control, pyrotechnic, range safety, deceleration, thermal protection, and retrieval systems. This represents the only human-rated, recoverable and refurbishable solid rocket ever developed and flown. Challenges included subsystem integration, thermal environments and severe loads (including water impact), sometimes resulting in hardware attrition. Several of the subsystems evolved during the program through design changes. These included the thermal protection system, range safety system, parachute/recovery system, and others. Obsolescence issues occasionally required component recertification. Because the system was recovered, the SRB was ideal for data and imagery acquisition, which proved essential for understanding loads and system response. The three main parachutes that lower the SRBs to the ocean are the largest parachutes ever designed, and the SRBs are the largest structures ever to be lowered by parachutes. SRB recovery from the ocean was a unique process and represented a significant operational challenge; requiring personnel, facilities, transportation, and ground support equipment. The SRB element achieved reliability via extensive system testing and checkout, redundancy management, and a thorough postflight assessment process. Assembly and integration of the booster subsystems was a unique process and acceptance testing of reused hardware components was required for each build. Extensive testing was done to assure hardware functionality at each level of stage integration. Because the booster element is recoverable, subsystems were available for inspection and testing postflight, unique to the Shuttle launch vehicle. Problems were noted and corrective actions were implemented as needed. The postflight assessment process was quite detailed and a significant portion of flight operations. The SRBs provided fully redundant critical systems including thrust vector control, mission critical pyrotechnics, avionics, and parachute recovery system. The design intent was to lift off with full redundancy. On occasion, the redundancy management scheme was needed during flight operations. This paper describes some of the design challenges, how the design evolved with time, and key areas where hardware reusability contributed to improved system level understanding.

  7. Real time test bed development for power system operation, control and cyber security

    NASA Astrophysics Data System (ADS)

    Reddi, Ram Mohan

    The operation and control of the power system in an efficient way is important in order to keep the system secure, reliable and economical. With advancements in smart grid, several new algorithms have been developed for improved operation and control. These algorithms need to be extensively tested and validated in real time before applying to the real electric power grid. This work focuses on the development of a real time test bed for testing and validating power system control algorithms, hardware devices and cyber security vulnerability. The test bed developed utilizes several hardware components including relays, phasor measurement units, phasor data concentrator, programmable logic controllers and several software tools. Current work also integrates historian for power system monitoring and data archiving. Finally, two different power system test cases are simulated to demonstrate the applications of developed test bed. The developed test bed can also be used for power system education.

  8. Integration and Test of Shuttle Small Payloads

    NASA Technical Reports Server (NTRS)

    Wright, Michael R.

    2003-01-01

    Recommended approaches for space shuttle small payload integration and test (I&T) are presented. The paper is intended for consideration by developers of shuttle small payloads, including I&T managers, project managers, and system engineers. Examples and lessons learned are presented based on the extensive history of NASA's Hitchhiker project. All aspects of I&T are presented, including: (1) I&T team responsibilities, coordination, and communication; (2) Flight hardware handling practices; (3) Documentation and configuration management; (4) I&T considerations for payload development; (5) I&T at the development facility; (6) Prelaunch operations, transfer, orbiter integration and interface testing; (7) Postflight operations. This paper is of special interest to those payload projects that have small budgets and few resources: that is, the truly faster, cheaper, better projects. All shuttle small payload developers are strongly encouraged to apply these guidelines during I&T planning and ground operations to take full advantage of today's limited resources and to help ensure mission success.

  9. The utility of the in vitro micronucleus test for evaluating the genotoxicity of natural and manmade nano-scale fibres.

    PubMed

    Fowler, Paul; Homan, Andrew; Atkins, Derek; Whitwell, James; Lloyd, Melvyn; Bradford, Roberta

    2016-10-01

    A range of fibrous materials, including several types of asbestos and carbon fibres with nano scale diameters that had reported positive genotoxicity data (predominantly clastogenicity), were tested in the in vitro micronucleus test (OECD 487) in GLP-compliant studies in Chinese Hamster Ovary cells. Out of eight materials tested, only one (crocidolite, an asbestos fibre) gave a positive response either in the presence or absence of metabolic activation (S9) and at short (3h) or extended (24h) exposure times (p≤0.001). Our data suggest that the commonly used tests for clastogenicity in mammalian cells require extensive modification before fibrous materials are detected as positive, raising questions about the validity of these tests for detecting clastogenic and aneugenic fibrous materials. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Cassini's Test Methodology for Flight Software Verification and Operations

    NASA Technical Reports Server (NTRS)

    Wang, Eric; Brown, Jay

    2007-01-01

    The Cassini spacecraft was launched on 15 October 1997 on a Titan IV-B launch vehicle. The spacecraft is comprised of various subsystems, including the Attitude and Articulation Control Subsystem (AACS). The AACS Flight Software (FSW) and its development has been an ongoing effort, from the design, development and finally operations. As planned, major modifications to certain FSW functions were designed, tested, verified and uploaded during the cruise phase of the mission. Each flight software upload involved extensive verification testing. A standardized FSW testing methodology was used to verify the integrity of the flight software. This paper summarizes the flight software testing methodology used for verifying FSW from pre-launch through the prime mission, with an emphasis on flight experience testing during the first 2.5 years of the prime mission (July 2004 through January 2007).

  11. Optimizing screening for tuberculosis and hepatitis B prior to starting tumor necrosis factor-α inhibitors in Crohn's disease.

    PubMed

    van der Have, Mike; Oldenburg, Bas; Fidder, Herma H; Belderbos, Tim D G; Siersema, Peter D; van Oijen, Martijn G H

    2014-03-01

    Treatment with tumor necrosis factor-α (TNF-α) inhibitors in patients with Crohn's disease (CD) is associated with potentially serious infections, including tuberculosis (TB) and hepatitis B virus (HBV). We assessed the cost-effectiveness of extensive TB screening and HBV screening prior to initiating TNF-α inhibitors in CD. We constructed two Markov models: (1) comparing tuberculin skin test (TST) combined with chest X-ray (conventional TB screening) versus TST and chest X-ray followed by the interferon-gamma release assay (extensive TB screening) in diagnosing TB; and (2) HBV screening versus no HBV screening. Our base-case included an adult CD patient starting with infliximab treatment. Input parameters were extracted from the literature. Direct medical costs were assessed and discounted following a third-party payer perspective. The main outcome was the incremental cost-effectiveness ratio (ICER). Sensitivity and Monte Carlo analyses were performed over wide ranges of probability and cost estimates. At base-case, the ICERs of extensive screening and HBV screening were €64,340 and €75,760 respectively to gain one quality-adjusted life year. Sensitivity analyses concluded that extensive TB screening was a cost-effective strategy if the latent TB prevalence is more than 12 % or if the false positivity rate of TST is more than 20 %. HBV screening became cost-effective if HBV reactivation or HBV-related mortality is higher than 37 and 62 %, respectively. Extensive TB screening and HBV screening are not cost-effective compared with conventional TB screening and no HBV screening, respectively. However, when targeted at high-risk patient groups, these screening strategies are likely to become cost-effective.

  12. Contact investigation after a fatal case of extensively drug-resistant tuberculosis (XDR-TB) in an aircraft, Germany, July 2013.

    PubMed

    An der Heiden, Maria; Hauer, Barbara; Fiebig, Lena; Glaser-Paschke, Gisela; Stemmler, Markus; Simon, Claudia; Rüsch-Gerdes, Sabine; Gilsdorf, Andreas; Haas, Walter

    2017-03-23

    In July 2013, a passenger died of infectious extensively drug-resistant tuberculosis (XDR-TB) on board of an aircraft after a 3-hour flight from Turkey to Germany. Initial information indicated the patient had moved about the aircraft coughing blood. We thus aimed to contact and inform all persons exposed within the aircraft and to test them for newly acquired TB infection. Two-stage testing within 8 weeks from exposure and at least 8 weeks after exposure was suggested, using either interferon gamma release assays (IGRAs) or tuberculin skin test (TST). The TST cut-off was defined at a diameter > 10 mm; for differentiation between conversion and boosting, conversion was defined as increase of skin induration > 5 mm. Overall, 155 passengers and seven crew members were included in the investigation: the questionnaire response rate was 83%; 112 (69%) persons were tested at least once for TB infection. In one passenger, who sat next to the area where the patient died, a test conversion was registered. As of March 2017, no secondary active TB cases have been reported. We describe an unusual situation in which we applied contact tracing beyond existing European guidelines; we found one latent tuberculosis infection in a passenger, which we consider probably newly acquired. This article is copyright of The Authors, 2017.

  13. Design and implementation of online automatic judging system

    NASA Astrophysics Data System (ADS)

    Liang, Haohui; Chen, Chaojie; Zhong, Xiuyu; Chen, Yuefeng

    2017-06-01

    For lower efficiency and poorer reliability in programming training and competition by currently artificial judgment, design an Online Automatic Judging (referred to as OAJ) System. The OAJ system including the sandbox judging side and Web side, realizes functions of automatically compiling and running the tested codes, and generating evaluation scores and corresponding reports. To prevent malicious codes from damaging system, the OAJ system utilizes sandbox, ensuring the safety of the system. The OAJ system uses thread pools to achieve parallel test, and adopt database optimization mechanism, such as horizontal split table, to improve the system performance and resources utilization rate. The test results show that the system has high performance, high reliability, high stability and excellent extensibility.

  14. A digitally implemented preambleless demodulator for maritime and mobile data communications

    NASA Astrophysics Data System (ADS)

    Chalmers, Harvey; Shenoy, Ajit; Verahrami, Farhad B.

    The hardware design and software algorithms for a low-bit-rate, low-cost, all-digital preambleless demodulator are described. The demodulator operates under severe high-noise conditions, fast Doppler frequency shifts, large frequency offsets, and multipath fading. Sophisticated algorithms, including a fast Fourier transform (FFT)-based burst acquisition algorithm, a cycle-slip resistant carrier phase tracker, an innovative Doppler tracker, and a fast acquisition symbol synchronizer, were developed and extensively simulated for reliable burst reception. The compact digital signal processor (DSP)-based demodulator hardware uses a unique personal computer test interface for downloading test data files. The demodulator test results demonstrate a near-ideal performance within 0.2 dB of theory.

  15. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    PubMed

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  16. Intracerebral hemorrhage with intraventricular extension and no hydrocephalus may not increase mortality or severe disability.

    PubMed

    Mahta, Ali; Katz, Paul M; Kamel, Hooman; Azizi, S Ausim

    2016-08-01

    This paper aimed to test the hypothesis that intraventricular extension of spontaneous intracerebral hemorrhage (ICH) in the absence of hydrocephalus is not associated with increased mortality or severe disability. We performed a retrospective consecutive cohort study of patients with primary spontaneous ICH who were admitted to a single institution. Multivariate logistic regression analysis was used to assess the association of each variable with functional outcome as measured by the modified Rankin Scale (mRS). A total of 164 patients met our inclusion criteria and were included in the study. Only hydrocephalus (p=0.002) and hematoma volume (p=0.006) were significantly associated with mortality or poor functional outcome (mRS of 3 to 6). In contrast, the presence of intraventricular hematoma was not independently associated with poor functional outcome. The presence of intraventricular extension of ICH in the absence of hydrocephalus may not increase mortality or disability. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Range Extension Opportunities While Heating a Battery Electric Vehicle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lustbader, Jason A; Rugh, John P; Titov, Eugene V

    The Kia Soul battery electric vehicle (BEV) is available with either a positive temperature coefficient (PTC) heater or an R134a heat pump (HP) with PTC heater combination (1). The HP uses both ambient air and waste heat from the motor, inverter, and on-board-charger (OBC) for its heat source. Hanon Systems, Hyundai America Technical Center, Inc. (HATCI) and the National Renewable Energy Laboratory jointly, with financial support from the U.S. Department of Energy, developed and proved-out technologies that extend the driving range of a Kia Soul BEV while maintaining thermal comfort in cold climates. Improved system configuration concepts that use thermalmore » storage and waste heat more effectively were developed and evaluated. Range extensions of 5%-22% at ambient temperatures ranging from 5 degrees C to -18 degrees C were demonstrated. This paper reviews the three-year effort, including test data of the baseline and modified vehicles, resulting range extension, and recommendations for future actions.« less

  18. Extending MAM5 Meta-Model and JaCalIV E Framework to Integrate Smart Devices from Real Environments.

    PubMed

    Rincon, J A; Poza-Lujan, Jose-Luis; Julian, V; Posadas-Yagüe, Juan-Luis; Carrascosa, C

    2016-01-01

    This paper presents the extension of a meta-model (MAM5) and a framework based on the model (JaCalIVE) for developing intelligent virtual environments. The goal of this extension is to develop augmented mirror worlds that represent a real and virtual world coupled, so that the virtual world not only reflects the real one, but also complements it. A new component called a smart resource artifact, that enables modelling and developing devices to access the real physical world, and a human in the loop agent to place a human in the system have been included in the meta-model and framework. The proposed extension of MAM5 has been tested by simulating a light control system where agents can access both virtual and real sensor/actuators through the smart resources developed. The results show that the use of real environment interactive elements (smart resource artifacts) in agent-based simulations allows to minimize the error between simulated and real system.

  19. Three Dimensional Analysis of the Final Design of Pier Extensions and West Guide Wall to Mitigate Local Scour Risk at the BNSF Railroad Bridge Downstream of the Prado Dam Supplemental Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lottes, S. A.; Sinha, N.; Bojanowski, C.

    This report is a supplement to a previous report [ref] covering optimization of wedge shaped pier extensions to streamline large bluff body piers as a local scour countermeasure for the Burlington Northern and Santa Fe (BNSF) Railroad Bridge over the Santa Ana River downstream of Prado Dam in Riverside County, CA. The optimized design was tested in a 1/30 scale physical model at U.S. Army Engineer Research and Development Center (ERDC) in Vicksburg, MS, and the optimized design was used as the base for the construction design. Constructability issues having to do with both materials and site conditions including accessmore » underneath the BNSF bridge yielded a construction design that required making the pier extensions wider and either moving the western curve of the west guide wall upstream or changing its geometry.« less

  20. Species traits and climate velocity explain geographic range shifts in an ocean-warming hotspot.

    PubMed

    Sunday, Jennifer M; Pecl, Gretta T; Frusher, Stewart; Hobday, Alistair J; Hill, Nicole; Holbrook, Neil J; Edgar, Graham J; Stuart-Smith, Rick; Barrett, Neville; Wernberg, Thomas; Watson, Reg A; Smale, Dan A; Fulton, Elizabeth A; Slawinski, Dirk; Feng, Ming; Radford, Ben T; Thompson, Peter A; Bates, Amanda E

    2015-09-01

    Species' ranges are shifting globally in response to climate warming, with substantial variability among taxa, even within regions. Relationships between range dynamics and intrinsic species traits may be particularly apparent in the ocean, where temperature more directly shapes species' distributions. Here, we test for a role of species traits and climate velocity in driving range extensions in the ocean-warming hotspot of southeast Australia. Climate velocity explained some variation in range shifts, however, including species traits more than doubled the variation explained. Swimming ability, omnivory and latitudinal range size all had positive relationships with range extension rate, supporting hypotheses that increased dispersal capacity and ecological generalism promote extensions. We find independent support for the hypothesis that species with narrow latitudinal ranges are limited by factors other than climate. Our findings suggest that small-ranging species are in double jeopardy, with limited ability to escape warming and greater intrinsic vulnerability to stochastic disturbances. © 2015 John Wiley & Sons Ltd/CNRS.

  1. Extending MAM5 Meta-Model and JaCalIV E Framework to Integrate Smart Devices from Real Environments

    PubMed Central

    2016-01-01

    This paper presents the extension of a meta-model (MAM5) and a framework based on the model (JaCalIVE) for developing intelligent virtual environments. The goal of this extension is to develop augmented mirror worlds that represent a real and virtual world coupled, so that the virtual world not only reflects the real one, but also complements it. A new component called a smart resource artifact, that enables modelling and developing devices to access the real physical world, and a human in the loop agent to place a human in the system have been included in the meta-model and framework. The proposed extension of MAM5 has been tested by simulating a light control system where agents can access both virtual and real sensor/actuators through the smart resources developed. The results show that the use of real environment interactive elements (smart resource artifacts) in agent-based simulations allows to minimize the error between simulated and real system. PMID:26926691

  2. Regulation of the hunting season as a tool for adaptive harvest management — First results for pink-footed geese Anser brachyrhynchus

    USGS Publications Warehouse

    Madsen, Jesper; Clausen, Kevin; Christensen, Thomas K.; Johnson, Fred A.

    2016-01-01

    Adjustment of hunting season length is often used to regulate harvest of waterbirds but the effects are disputed. We describe the first results of season length extension on the harvest of the pink-footed goose, which has been selected as the first test case of adaptive harvest management of waterbirds in Europe. In Denmark, the season (previously 1 September to 31 December) was extended to include January in 2014-15 with the aim to increase the harvest and, in the longer term, reduce the population size. The total harvest in Denmark increased by 52% compared to previous years, and almost 50% of the Danish harvest was taken in the January extension. In the course of the hunting season, the proportion of adults in the bag increased. In this case, the outcomes from the first extension of season suggest that season length adjustment can be an effective tool to regulate harvest, though dependent on winter weather conditions and hunters’ motivation for shooting geese.

  3. Results of an independent evaluation of Project ALERT delivered in schools by Cooperative Extension.

    PubMed

    St Pierre, Tena L; Osgood, D Wayne; Mincemoyer, Claudia C; Kaltreider, D Lynne; Kauh, Tina J

    2005-12-01

    Reported are results of an independent effectiveness study of the Project ALERT drug prevention program implemented in eight Pennsylvania middle schools by outside program leaders employed by Cooperative Extension. In this randomized, 2-cohort longitudinal evaluation, 1,649 seventh-grade students completed a pretest and four waves of posttests over the 2-year program and 1-year follow-up. Project ALERT's effectiveness was tested through a 3-level hierarchical linear model. Analyses failed to yield any positive effects for substance use or mediators for use in the adult or teen-assisted delivery of the curriculum. An extensive set of additional analyses detected no differential program effects by student risk level, gender, school, or level of implementation quality. Potential explanations for outcomes relative to Project ALERT's original effectiveness trial are discussed, as well as implications for future research, including the need to conduct independent effectiveness studies of previously validated programs in a variety of contexts.

  4. Laterally Loaded Partially Prestressed Concrete Piles

    DTIC Science & Technology

    1989-09-01

    of an extensive test program onl laterali y ioadeu. partially pr- estressed concrete fender piles. The study Included service load range as well ats...12,000-psi design strength). Configura- tion G utilized 14 r:- estress strand, in an unsymmetric pattern. To provide a uniform concrete prestress of 540...sudden loss in load carrying capacity directly related to the loss of concrete area. The compression concrete fractured longitudinally and along the

  5. Use of the JPL Electronic Nose to detect leaks and spills in an enclosed environment

    NASA Technical Reports Server (NTRS)

    Ryan, Margaret A.; Homer, M. L.; Zhou, H.; Pelletier, C. C.; Manatt, K.; Jewell, A. D.; Kisor, A.; Shevade, A. V.; Lewis, C. R.; Taylor, C. J.; hide

    2006-01-01

    An electronic nose to be used as an air quality monitor in human habitats in space has been developed at the Jet Propulsion Laboratory. This device is capable of detecting, identifying and quantifying several organic and inorganic chemical species which might be present as contaminants in spacecraft air. The complete portable device, including sensors, electronics, and software for data analysis, has been extensively tested.

  6. HYPERDIRE-HYPERgeometric functions DIfferential REduction: Mathematica-based packages for the differential reduction of generalized hypergeometric functions: Lauricella function FC of three variables

    NASA Astrophysics Data System (ADS)

    Bytev, Vladimir V.; Kniehl, Bernd A.

    2016-09-01

    We present a further extension of the HYPERDIRE project, which is devoted to the creation of a set of Mathematica-based program packages for manipulations with Horn-type hypergeometric functions on the basis of differential equations. Specifically, we present the implementation of the differential reduction for the Lauricella function FC of three variables. Catalogue identifier: AEPP_v4_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEPP_v4_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU General Public License, version 3 No. of lines in distributed program, including test data, etc.: 243461 No. of bytes in distributed program, including test data, etc.: 61610782 Distribution format: tar.gz Programming language: Mathematica. Computer: All computers running Mathematica. Operating system: Operating systems running Mathematica. Classification: 4.4. Does the new version supersede the previous version?: No, it significantly extends the previous version. Nature of problem: Reduction of hypergeometric function FC of three variables to a set of basis functions. Solution method: Differential reduction. Reasons for new version: The extension package allows the user to handle the Lauricella function FC of three variables. Summary of revisions: The previous version goes unchanged. Running time: Depends on the complexity of the problem.

  7. Analysis of Chemical Bioactivity through In Vitro Profiling ...

    EPA Pesticide Factsheets

    Safety assessment of drugs and environmental chemicals relies extensively on animal testing. However, the quantity of chemicals needing assessment and challenges of species extrapolation drive the development of alternative approaches. The EPA’s ToxCast and the multiagency Tox21 programs address this through use of an extensive in vitro screening program to generate data on a large library of important environmental chemicals. These in vitro assays encompass both cell-free, biochemical assays targeting proteins that may be potential molecular initiating events and cellular assays that provide coverage of critical signaling pathways and toxicity phenotypes. Effects on model organisms such as the developing zebrafish, are also part of the testing strategy. A variety of computational approaches are used to analyze the resulting complex data sets to gain insight in to inherent biological activity of chemicals and possible mechanisms of toxicity. Several case studies including identification of modulators of estrogen receptor and aromatic hydrocarbon receptor pathways with effects in primary human cell systems will be described. In addition, existing in vivo data from a subset of the chemicals was used to anchor predictive models using in vitro data for a number of adverse endpoints including reproductive and developmental toxicities. The strengths and weaknesses of this approach will be described. This work does not necessarily reflect official Agency policy. Pres

  8. Sleep and vestibular adaptation: implications for function in microgravity

    NASA Technical Reports Server (NTRS)

    Hobson, J. A.; Stickgold, R.; Pace-Schott, E. F.; Leslie, K. R.

    1998-01-01

    Optimal human performance depends upon integrated sensorimotor and cognitive functions, both of which are known to be exquisitely sensitive to loss of sleep. Under the microgravity conditions of space flight, adaptation of both sensorimotor (especially vestibular) and cognitive functions (especially orientation) must occur quickly--and be maintained--despite any concurrent disruptions of sleep that may be caused by microgravity itself, or by the uncomfortable sleeping conditions of the spacecraft. It is the three-way interaction between sleep quality, general work efficiency, and sensorimotor integration that is the subject of this paper and the focus of new work in our laboratory. To record sleep under field conditions including microgravity, we utilize a novel system called the Nightcap that we have developed and extensively tested on normal and sleep-disordered subjects. To perturb the vestibular system in ground-based studies, we utilize a variety of experimental conditions including optokinetic stimulation and both minifying and reversing goggle paradigms that have been extensively studied in relation to plasticity of the vestibulo-ocular reflex. Using these techniques we will test the hypothesis that vestibular adaptation both provokes and is enhanced by REM sleep under both ground-based and space conditions. In this paper we describe preliminary results of some of our studies.

  9. Effects of sleep manipulation on cognitive functioning of adolescents: A systematic review.

    PubMed

    de Bruin, Eduard J; van Run, Chris; Staaks, Janneke; Meijer, Anne Marie

    2017-04-01

    Adolescents are considered to be at risk for deteriorated cognitive functioning due to insufficient sleep. This systematic review examined the effects of experimental sleep manipulation on adolescent cognitive functioning. Sleep manipulations consisted of total or partial sleep restriction, sleep extension, and sleep improvement. Only articles written in English, with participants' mean age between 10 and 19 y, using objective sleep measures and cognitive performance as outcomes were included. Based on these criteria 16 articles were included. The results showed that the sleep manipulations were successful. Partial sleep restriction had small or no effects on adolescent cognitive functioning. Sleep deprivation studies showed decrements in the psychomotor vigilance task as most consistent finding. Sleep extension and sleep improvement contributed to improvement of working memory. Sleep directly after learning improved memory consolidation. Due to the great diversity of tests and lack of coherent results, decisive conclusions could not be drawn about which domains in particular were influenced by sleep manipulation. Small number of participants, not accounting for the role of sleep quality, individual differences in sleep need, compensatory mechanisms in adolescent sleep and cognitive functioning, and the impurity problem of cognitive tests might explain the absence of more distinct results. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Optimal sagittal motion axis for trunk extension and flexion tests in chronic low back trouble.

    PubMed

    Rantanen, P; Nykvist, F

    2000-11-01

    To find the optimal height for sagittal motion axis for trunk strength test in chronic low back trouble. Cross-sectional study. The strength of trunk muscles of low back pain patients is decreased. The measured strength depends on the height of the sagittal motion axis but the differences between patients and controls are not known. 114 (67 female) patients with chronic low back trouble are classified according to Quebec Task Force, 50 (31 female) patients with rheumatic disorder, but without low back trouble, and 33 (22 female) healthy controls, no appreciable physical differences but clear differences in Oswestry score. Isometric trunk extension-flexion test with different heights for the pelvic fulcrum. Force decreased in extension, increased in flexion, and torque increased both in flexion and extension in every group (P<0.001) as the fulcrum was moved caudally. The male controls were stronger than patients with low back trouble (P<0.01). The female controls were stronger only if the fulcrum was set at the hip joint level (P<0.05). There were no differences between patients with rheumatic disorder and low back trouble, except in extension if the fulcrum was at the hip joint level (P<0.02). The rotation axis in trunk extension-flexion strength test should be set at the level of the hip joint. Trunk muscle weakness is a common sign of different rheumatic disorders. Proper setting of sagittal motion axis and concomitant measurement of trunk and hip extensor or flexor muscles increases the specificity of the strength test for low back trouble.

  11. Progress towards extreme attitude testing with Magnetic Suspension and Balance Systems

    NASA Technical Reports Server (NTRS)

    Britcher, Colin P.; Parker, David H.

    1988-01-01

    Progress is reported in a research effort aimed towards demonstration of the feasibility of suspension and aerodynamic testing of models at high angles of attack in wind tunnel Magnetic Suspension and Balance Systems. Extensive modifications, described in this paper, have been made to the Southampton University suspension system in order to facilitate this work. They include revision of electromagnet configuration, installation of all-new position sensors and expansion of control system programs. An angle of attack range of 0 to 90 deg is expected for axisymmetric models. To date, suspension up to 80 deg angle of attack has been achieved.

  12. Wind tunnel testing of low-drag airfoils

    NASA Technical Reports Server (NTRS)

    Harvey, W. Donald; Mcghee, R. J.; Harris, C. D.

    1986-01-01

    Results are presented for the measured performance recently obtained on several airfoil concepts designed to achieve low drag by maintaining extensive regions of laminar flow without compromising high-lift performance. The wind tunnel results extend from subsonic to transonic speeds and include boundary-layer control through shaping and suction. The research was conducted in the NASA Langley 8-Ft Transonic Pressure Tunnel (TPT) and Low Turbulence Pressure Tunnel (LTPT) which have been developed for testing such low-drag airfoils. Emphasis is placed on identifying some of the major factors influencing the anticipated performance of low-drag airfoils.

  13. Final Report: System Reliability Model for Solid-State Lighting (SSL) Luminaires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, J. Lynn

    2017-05-31

    The primary objectives of this project was to develop and validate reliability models and accelerated stress testing (AST) methodologies for predicting the lifetime of integrated SSL luminaires. This study examined the likely failure modes for SSL luminaires including abrupt failure, excessive lumen depreciation, unacceptable color shifts, and increased power consumption. Data on the relative distribution of these failure modes were acquired through extensive accelerated stress tests and combined with industry data and other source of information on LED lighting. This data was compiled and utilized to build models of the aging behavior of key luminaire optical and electrical components.

  14. The Kepler End-to-End Model: Creating High-Fidelity Simulations to Test Kepler Ground Processing

    NASA Technical Reports Server (NTRS)

    Bryson, Stephen T.; Jenkins, Jon M.; Peters, Dan J.; Tenenbaum, Peter P.; Klaus, Todd C.; Gunter, Jay P.; Cote, Miles T.; Caldwell, Douglas A.

    2010-01-01

    The Kepler mission is designed to detect the transit of Earth-like planets around Sun-like stars by observing 100,000 stellar targets. Developing and testing the Kepler ground-segment processing system, in particular the data analysis pipeline, requires high-fidelity simulated data. This simulated data is provided by the Kepler End-to-End Model (ETEM). ETEM simulates the astrophysics of planetary transits and other phenomena, properties of the Kepler spacecraft and the format of the downlinked data. Major challenges addressed by ETEM include the rapid production of large amounts of simulated data, extensibility and maintainability.

  15. Burnout among Extension Agents in the Ohio Cooperative Extension Service.

    ERIC Educational Resources Information Center

    Igodan, O. Chris; Newcomb, L. H.

    A study examined the extent and causes of burnout among extension agents in Ohio. From the 241 extension agents working in the 88 counties of Ohio, researchers selected a random sample of 101 agents. Included in the sample were 34 agriculture agents, 33 home economics agents. Included in the sample agents were asked to complete a survey…

  16. Manual muscle testing: a method of measuring extremity muscle strength applied to critically ill patients.

    PubMed

    Ciesla, Nancy; Dinglas, Victor; Fan, Eddy; Kho, Michelle; Kuramoto, Jill; Needham, Dale

    2011-04-12

    Survivors of acute respiratory distress syndrome (ARDS) and other causes of critical illness often have generalized weakness, reduced exercise tolerance, and persistent nerve and muscle impairments after hospital discharge. Using an explicit protocol with a structured approach to training and quality assurance of research staff, manual muscle testing (MMT) is a highly reliable method for assessing strength, using a standardized clinical examination, for patients following ARDS, and can be completed with mechanically ventilated patients who can tolerate sitting upright in bed and are able to follow two-step commands. (7, 8) This video demonstrates a protocol for MMT, which has been taught to ≥ 43 research staff who have performed >800 assessments on >280 ARDS survivors. Modifications for the bedridden patient are included. Each muscle is tested with specific techniques for positioning, stabilization, resistance, and palpation for each score of the 6-point ordinal Medical Research Council scale. Three upper and three lower extremity muscles are graded in this protocol: shoulder abduction, elbow flexion, wrist extension, hip flexion, knee extension, and ankle dorsiflexion. These muscles were chosen based on the standard approach for evaluating patients for ICU-acquired weakness used in prior publications. (1,2).

  17. On-road and wind-tunnel measurement of motorcycle helmet noise.

    PubMed

    Kennedy, J; Carley, M; Walker, I; Holt, N

    2013-09-01

    The noise source mechanisms involved in motorcycling include various aerodynamic sources and engine noise. The problem of noise source identification requires extensive data acquisition of a type and level that have not previously been applied. Data acquisition on track and on road are problematic due to rider safety constraints and the portability of appropriate instrumentation. One way to address this problem is the use of data from wind tunnel tests. The validity of these measurements for noise source identification must first be demonstrated. In order to achieve this extensive wind tunnel tests have been conducted and compared with the results from on-track measurements. Sound pressure levels as a function of speed were compared between on track and wind tunnel tests and were found to be comparable. Spectral conditioning techniques were applied to separate engine and wind tunnel noise from aerodynamic noise and showed that the aerodynamic components were equivalent in both cases. The spectral conditioning of on-track data showed that the contribution of engine noise to the overall noise is a function of speed and is more significant than had previously been thought. These procedures form a basis for accurate experimental measurements of motorcycle noise.

  18. Influence of hamstring muscles extensibility on spinal curvatures and pelvic tilt in highly trained cyclists.

    PubMed

    Muyor, José M; Alacid, Fernando; López-Miñarro, Pedro A

    2011-09-01

    The purpose of this study was to determine the influence of hamstring muscles extensibility in standing, maximal trunk flexion with knees extended and on the bicycle in lower handlebar-hands position of highly trained cyclists. Ninety-six cyclists were recruited for the study (mean ± SD, age: 30.36 ± 5.98 years). Sagittal spinal curvatures and pelvic tilt were measured in the standing position, maximal trunk flexion with knees extended (sit-and-reach test) and while sitting on a bicycle in lower handlebar-hand position using a Spinal Mouse system. Hamstring muscles extensibility was determined in both legs by passive straight leg raise test (PSLR). The sample was divided into three groups according to PSLR angle: (1) reduced extensibility (PSLR < 80º; n = 30), (2) moderate hamstring extensibility group (PSLR = 80º - 90º; n = 35), and (3) high hamstring extensibility (PSLR = > 90º; n = 31). ANOVA analysis showed significant differences among groups for thoracic (p < 0.001) and pelvic tilt (p < 0.001) angles in the sit-and-reach test. No differences were found between groups for standing and on the bicycle position. Post hoc analysis showed significant differences in all pairwise comparisons for thoracic angle (p < 0.01) and pelvic angle (p < 0.001) in the sit-and-reach test. No differences were found in lumbar angle in any posture. In conclusion, the hamstring muscles extensibility influence the thoracic and pelvic postures when maximal trunk flexion with knees extended is performed, but not when cyclists are seated on their bicycles.

  19. Influence of Hamstring Muscles Extensibility on Spinal Curvatures and Pelvic Tilt in Highly Trained Cyclists

    PubMed Central

    Muyor, José M.; Alacid, Fernando; López-Miñarro, Pedro A.

    2011-01-01

    The purpose of this study was to determine the influence of hamstring muscles extensibility in standing, maximal trunk flexion with knees extended and on the bicycle in lower handlebar-hands position of highly trained cyclists. Ninety-six cyclists were recruited for the study (mean ± SD, age: 30.36 ± 5.98 years). Sagittal spinal curvatures and pelvic tilt were measured in the standing position, maximal trunk flexion with knees extended (sit-and-reach test) and while sitting on a bicycle in lower handlebar-hand position using a Spinal Mouse system. Hamstring muscles extensibility was determined in both legs by passive straight leg raise test (PSLR). The sample was divided into three groups according to PSLR angle: (1) reduced extensibility (PSLR < 80º; n = 30), (2) moderate hamstring extensibility group (PSLR = 80º – 90º; n = 35), and (3) high hamstring extensibility (PSLR = > 90º; n = 31). ANOVA analysis showed significant differences among groups for thoracic (p < 0.001) and pelvic tilt (p < 0.001) angles in the sit-and-reach test. No differences were found between groups for standing and on the bicycle position. Post hoc analysis showed significant differences in all pairwise comparisons for thoracic angle (p < 0.01) and pelvic angle (p < 0.001) in the sit-and-reach test. No differences were found in lumbar angle in any posture. In conclusion, the hamstring muscles extensibility influence the thoracic and pelvic postures when maximal trunk flexion with knees extended is performed, but not when cyclists are seated on their bicycles PMID:23486997

  20. Long-term Immunogenicity of Elosulfase Alfa in the Treatment of Morquio A Syndrome: Results From MOR-005, a Phase III Extension Study.

    PubMed

    Long, Brian; Tompkins, Troy; Decker, Celeste; Jesaitis, Lynne; Khan, Shahid; Slasor, Peter; Harmatz, Paul; O'Neill, Charles A; Schweighardt, Becky

    2017-01-01

    Elosulfase alfa is an enzyme replacement therapy for the treatment of Morquio A syndrome (mucopolysaccharidosis IVA), a lysosomal storage disorder caused by a deficiency of the enzyme N-acetylgalactose-amine-6-sulfatase. We previously reported immunogenicity data from our 24-week placebo-controlled Phase III study, MOR-004. Here, we report the long-term immunogenicity profile of elosulfase alfa from MOR-005, the Phase III extension trial to assess potential correlations between antidrug antibodies and efficacy and safety profile outcomes throughout 120 weeks of treatment. The long-term immunogenicity of elosulfase alfa was evaluated in patients with Morquio A syndrome in an open-label extension study for a total of 120 weeks. All patients received 2.0 mg/kg elosulfase alfa either weekly or every other week before establishment of 2.0 mg/kg/wk as the recommended dose, at which time all patients received weekly treatment. Efficacy measures were compared with those from the MOR-004 baseline, enabling analysis of changes over 120 weeks. The primary efficacy measure was the change from baseline in 6-minute walk test. Secondary measures included changes from baseline in 3-minute stair climb test and normalized urine keratan sulfate, a pharmacodynamic metric. All patients treated with elosulfase alfa developed antidrug total antibodies (TAb) by week 24 of MOR-004. In the extension study, all patients, including those who had previously received placebo, were TAb positive by study week 36 (MOR-005 week 12). All patients remained TAb positive throughout the study, and TAb titers were similar across treatment groups at week 120. Nearly all patients tested positive for neutralizing antibodies (NAb) at least once, with incidence of NAb positivity peaking at 85.9% at study week 36, then steadily declining to 66.0% at study week 120. In all treatment groups, mean urine keratan sulfate remained below treatment-naive baseline despite the presence of antidrug antibodies. No relationship was observed between TAb titers or NAb positivity and changes in urine keratan sulfate, 6-minute walk test, or 3-minute stair climb test from baseline to week 120. No consistent associations were detected between antidrug antibodies and the occurrence of hypersensitivity adverse events or anaphylaxis over the course of the study. Immunogenicity results from this long-term study are consistent with previously reported 24-week results. Despite the sustained presence of antidrug antibodies, elosulfase alfa was well tolerated, and patients continued to benefit from treatment through week 120. No associations were detected between higher TAb titers or NAb positivity and reduced treatment effect or worsened safety profile measures. ClinicalTrials.gov identifier: NCT01415427. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Mechanical Analysis of W78/88-1 Life Extension Program Warhead Design Options

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spencer, Nathan

    2014-09-01

    Life Extension Program (LEP) is a program to repair/replace components of nuclear weapons to ensure the ability to meet military requirements. The W78/88-1 LEP encompasses the modernization of two major nuclear weapon reentry systems into an interoperable warhead. Several design concepts exist to provide different options for robust safety and security themes, maximum non-nuclear commonality, and cost. Simulation is one capability used to evaluate the mechanical performance of the designs in various operational environments, plan for system and component qualification efforts, and provide insight into the survivability of the warhead in environments that are not currently testable. The simulation effortsmore » use several Sandia-developed tools through the Advanced Simulation and Computing program, including Cubit for mesh generation, the DART Model Manager, SIERRA codes running on the HPC TLCC2 platforms, DAKOTA, and ParaView. Several programmatic objectives were met using the simulation capability including: (1) providing early environmental specification estimates that may be used by component designers to understand the severity of the loads their components will need to survive, (2) providing guidance for load levels and configurations for subassembly tests intended to represent operational environments, and (3) recommending design options including modified geometry and material properties. These objectives were accomplished through regular interactions with component, system, and test engineers while using the laboratory's computational infrastructure to effectively perform ensembles of simulations. Because NNSA has decided to defer the LEP program, simulation results are being documented and models are being archived for future reference. However, some advanced and exploratory efforts will continue to mature key technologies, using the results from these and ongoing simulations for design insights, test planning, and model validation.« less

  2. Separation of crack extension modes in orthotropic delamination models

    NASA Technical Reports Server (NTRS)

    Beuth, Jack L.

    1995-01-01

    In the analysis of an interface crack between dissimilar elastic materials, the mode of crack extension is typically not unique, due to oscillatory behavior of near-tip stresses and displacements. This behavior currently limits the applicability of interfacial fracture mechanics as a means to predict composite delamination. The Virtual Crack Closure Technique (VCCT) is a method used to extract mode 1 and mode 2 energy release rates from numerical fracture solutions. The mode of crack extension extracted from an oscillatory solution using the VCCT is not unique due to the dependence of mode on the virtual crack extension length, Delta. In this work, a method is presented for using the VCCT to extract Delta-independent crack extension modes for the case of an interface crack between two in-plane orthotropic materials. The method does not involve altering the analysis to eliminate its oscillatory behavior. Instead, it is argued that physically reasonable, Delta-independent modes of crack extension can be extracted from oscillatory solutions. Knowledge of near-tip fields is used to determine the explicit Delta dependence of energy release rate parameters. Energy release rates are then defined that are separated from the oscillatory dependence on Delta. A modified VCCT using these energy release rate definitions is applied to results from finite element analyses, showing that Delta-independent modes of crack extension result. The modified technique has potential as a consistent method for extracting crack extension modes from numerical solutions. The Delta-independent modes extracted using this technique can also serve as guides for testing the convergence of finite element models. Direct applications of this work include the analysis of planar composite delamination problems, where plies or debonded laminates are modeled as in-plane orthotropic materials.

  3. Testing in Support of Space Fission System Development and Qualification

    NASA Technical Reports Server (NTRS)

    Houts, Mike; Bragg-Sitton, Shannon; Garber, Anne; Godfrey, Tom; Martin, Jim; Pearson, Boise; Webster, Kenny

    2007-01-01

    Extensive data would be required for the qualification of a fission surface power (FSP) system. The strategy for qualifying a FSP system could have a significant programmatic impact. This paper explores potential options that could be used for qualifying FSP systems, including cost-effective means for obtaining required data. three methods for obtaining qualification data are analysis, non-nuclear testing, and nuclear testing. It has been over 40 years since the US qualified a space reactor for launch. During that time, advances have been made related to all three methods. Perhaps the greatest advancement has occurred in the area of computational tools for design and analysis. Tools that have been developed, coupled with modem computers, would have a significant impact on a FSP qualification. This would be especially true for systems with materials and fuels operating well within temperature, irradiation damage, and burnup limits. The ability to perform highly realistic non-nuclear testing has also advanced throughout the past four decades. Instrumented thermal simulators were developed during the 1970s and 1980s to assist in the development, operation, and assessment of terrestrial fission systems. Instrumented thermal simulators optimized for assisting in the development, operation, and assessment of modem FSP systems have been under development (and utilized) since 1998. These thermal simulators enable heat from fission to be closely mimicked (axial power profile, radial power profile, temperature, heat flux, etc.} and extensive data to be taken from the core region. Both steady-state and transient operation can be tested. For transient testing, reactivity feedback is calculated (or measured in cold/warm criticals) based on reactor temperature and/or dimensional changes. Pin power during a transient is then calculated based on the reactivity feedback that would occur given measured values of temperature and/or dimensional change. In this way nonnuclear testing can be used to provide very realistic information related to nuclear operation. Non-nuclear testing can be used at all levels, including component, subsystem, and integrated system testing. Realistic non-nuclear testing is most useful for systems operating within known temperature, irradiation damage, and burnup capabilities.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonzon, L. L.; Hente, D. B.; Kukreti, B. M.

    The seismic-fragility response of naturally-aged, nuclear station, safety-related batteries is of interest for two reasons: (1) to determine actual failure modes and thresholds; and (2) to determine the validity of using the electrical capacity of individual cells as an indicator of the end-of-life of a battery, given a seismic event. This report covers the first test series of an extensive program using 12-year old, lead-calcium, Gould NCX-2250 cells, from the James A. Fitzpatrick Nuclear Power Station operated by the New York Power Authority. Seismic tests with three cell configurations were performed using a triaxial shake table: single-cell tests, rigidly mounted;more » multi-cell (three) tests, mounted in a typical battery rack; and single-cell tests specifically aimed towards examining propagation of pre-existing case cracks. In general the test philosophy was to monitor the electrical properties including discharge capacity of cells through a graduated series of g-level step increases until either the shake-table limits were reached or until electrical failure of the cells occurred. Of nine electrically active cells, six failed during seismic testing over a range of imposed g-level loads in excess of a 1-g ZPA. Post-test examination revealed a common failure mode, the cracking at the abnormally brittle, positive lead bus-bar/post interface; further examination showed that the failure zone was extremely coarse grained and extensively corroded. Presently accepted accelerated-aging methods for qualifying batteries, per IEEE Std. 535-1979, are based on plate growth, but these naturally-aged 12-year old cells showed no significant plate growth.« less

  5. Hardware fault insertion and instrumentation system: Mechanization and validation

    NASA Technical Reports Server (NTRS)

    Benson, J. W.

    1987-01-01

    Automated test capability for extensive low-level hardware fault insertion testing is developed. The test capability is used to calibrate fault detection coverage and associated latency times as relevant to projecting overall system reliability. Described are modifications made to the NASA Ames Reconfigurable Flight Control System (RDFCS) Facility to fully automate the total test loop involving the Draper Laboratories' Fault Injector Unit. The automated capability provided included the application of sequences of simulated low-level hardware faults, the precise measurement of fault latency times, the identification of fault symptoms, and bulk storage of test case results. A PDP-11/60 served as a test coordinator, and a PDP-11/04 as an instrumentation device. The fault injector was controlled by applications test software in the PDP-11/60, rather than by manual commands from a terminal keyboard. The time base was especially developed for this application to use a variety of signal sources in the system simulator.

  6. Human subjects concerns in ground based ECLSS testing - Managing uncertainty in closely recycled systems

    NASA Technical Reports Server (NTRS)

    Crump, William J.; Janik, Daniel S.; Thomas, L. Dale

    1990-01-01

    U.S. space missions have to this point used water either made on board or carried from earth and discarded after use. For Space Station Freedom, long duration life support will include air and water recycling using a series of physical-chemical subsystems. The Environmental Control and Life Support System (ECLSS) designed for this application must be tested extensively at all stages of hardware maturity. Human test subjects are required to conduct some of these tests, and the risks associated with the use of development hardware must be addressed. Federal guidelines for protection of human subjects require careful consideration of risks and potential benefits by an Institutional Review Board (IRB) before and during testing. This paper reviews the ethical principles guiding this consideration, details the problems and uncertainties inherent in current hardware testing, and presents an incremental approach to risk assessment for ECLSS testing.

  7. Specialization of tendon mechanical properties results from interfascicular differences

    PubMed Central

    Thorpe, Chavaunne T.; Udeze, Chineye P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R. C.

    2012-01-01

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage. PMID:22764132

  8. Specialization of tendon mechanical properties results from interfascicular differences.

    PubMed

    Thorpe, Chavaunne T; Udeze, Chineye P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2012-11-07

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage.

  9. COMPARISON OF DIFFERENT TRUNK ENDURANCE TESTING METHODS IN COLLEGE‐AGED INDIVIDUALS

    PubMed Central

    Krier, Amber D.; Nelson, Julie A.; Rogers, Michael A.; Stuke, Zachariah O.; Smith, Barbara S.

    2012-01-01

    Objective: Determine the reliability of two different modified (MOD1 and MOD2) testing methods compared to a standard method (ST) for testing trunk flexion and extension endurance. Participants: Twenty‐eight healthy individuals (age 26.4 ± 3.2 years, height 1.75 ± m, weight 71.8 ± 10.3 kg, body mass index 23.6 ± 3.4 m/kg2). Method: Trunk endurance time was measured in seconds for flexion and extension under the three different stabilization conditions. The MOD1 testing procedure utilized a female clinician (70.3 kg) and MOD2 utilized a male clinician (90.7 kg) to provide stabilization as opposed to the ST method of belt stabilization. Results: No significant differences occurred between flexion and extension times. Intraclass correlations (ICCs3,1) for the different testing conditions ranged from .79 to .95 (p <.000) and are found in Table 3. Concurrent validity using the ST flexion times as the gold standard coefficients were .95 for MOD1 and .90 for MOD2. For ST extension, coefficients were .91 and .80, for MOD1 and MOD2 respectively (p <.01). Conclusions: These methods proved to be a reliable substitute for previously accepted ST testing methods in normal college‐aged individuals. These modified testing procedures can be implemented in athletic training rooms and weight rooms lacking appropriate tables for the ST testing. Level of Evidence: 3 PMID:23091786

  10. The nuclear present. A guide to recent books on nuclear war, weapons, the peace movement, and related issues, with a chronology of nuclear events, 1789-1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burns, G.

    The Nuclear Present brings the interested reader up-to-date on significant English-language books about nuclear weapons and related topics, identifying primarily important works of nuclear non-fiction that have come out since 1984. Each reference has a paragraph of comment about its subject and value. General organizational areas include the following: Reference Works; Nuclear weapons and Nuclear war (14 sub-headings including overviews, development, effects, tests, arms race, prospectives, legal considerations etc.); Strategy; proliferation; Stratigic Defense; Arms control and disarmament; ethical, pholosophical and religous perspectives; new paths to peace; periodic guide; the Chernobyl Disaster. An extensive Nuclear Chronology (1789-1991) written by the authormore » allows a fairly detailed sense of the historical record of nuclear weapons, including testing, manufacture, use and movements for arms control and disarmament.« less

  11. A comprehensive method for preliminary design optimization of axial gas turbine stages. II - Code verification

    NASA Technical Reports Server (NTRS)

    Jenkins, R. M.

    1983-01-01

    The present effort represents an extension of previous work wherein a calculation model for performing rapid pitchline optimization of axial gas turbine geometry, including blade profiles, is developed. The model requires no specification of geometric constraints. Output includes aerodynamic performance (adiabatic efficiency), hub-tip flow-path geometry, blade chords, and estimates of blade shape. Presented herein is a verification of the aerodynamic performance portion of the model, whereby detailed turbine test-rig data, including rig geometry, is input to the model to determine whether tested performance can be predicted. An array of seven (7) NASA single-stage axial gas turbine configurations is investigated, ranging in size from 0.6 kg/s to 63.8 kg/s mass flow and in specific work output from 153 J/g to 558 J/g at design (hot) conditions; stage loading factor ranges from 1.15 to 4.66.

  12. Effect of testing for cancer on cancer- and venous thromboembolism (VTE)-related mortality and morbidity in people with unprovoked VTE.

    PubMed

    Robertson, Lindsay; Yeoh, Su Ern; Stansby, Gerard; Agarwal, Roshan

    2017-08-23

    Venous thromboembolism (VTE) is a collective term for two conditions: deep vein thrombosis (DVT) and pulmonary embolism (PE). A proportion of people with VTE have no underlying or immediately predisposing risk factors and the VTE is referred to as unprovoked. Unprovoked VTE can often be the first clinical manifestation of an underlying malignancy. This has raised the question of whether people with an unprovoked VTE should be investigated for an underlying cancer. Treatment for VTE is different in cancer and non-cancer patients and a correct diagnosis would ensure that people received the optimal treatment for VTE to prevent recurrence and further morbidity. Furthermore, an appropriate cancer diagnosis at an earlier, potentially curative stage could avoid the risk of cancer progression and thus lead to improvements in cancer-related mortality and morbidity. This is an update of a review first published in 2015. To determine whether testing for undiagnosed cancer in people with a first episode of unprovoked VTE (DVT of the lower limb or PE) is effective in reducing cancer and VTE-related mortality and morbidity and to determine which tests for cancer are best at identifying treatable cancers early. For this update, the Cochrane Vascular Information Specialist (CIS) searched the Specialised Register (16 February 2017). In addition, the CIS searched the Cochrane Register of Studies CENTRAL (2017, Issue 1). We searched trials registries (February 2017) and checked the reference lists of relevant articles. Randomised and quasi-randomised trials in which people with an unprovoked VTE were allocated to receive specific tests for cancer or clinically indicated tests only were eligible for inclusion in this review. Primary outcomes included all-cause mortality, cancer-related mortality and VTE-related mortality. Two review authors independently selected studies, assessed quality and extracted data. We resolved any disagreements by discussion. Four studies with 1644 participants met the inclusion criteria (two studies in the original review and two in this update). Two studies assessed the effect of extensive tests versus tests at the physician's discretion) while the other two studies assessed the effect of standard testing plus positron emission tomography (PET)/computed tomography (CT) scanning versus standard testing alone. For extensive tests versus tests at the physician's discretion, the quality of the evidence was low due to risk of bias (early termination of the studies). When comparing standard testing plus PET/CT scanning versus standard testing alone, the quality of evidence was moderate due to a risk of detection bias. The quality of the evidence was downgraded further when detection bias was present in one study with a low number of events.When comparing extensive tests versus tests at the physician's discretion, pooled analysis on two studies showed that testing for cancer was consistent with either a benefit or no benefit on cancer-related mortality (odds ratio (OR) 0.49, 95% confidence interval (CI) 0.15 to 1.67; 396 participants; 2 studies; P = 0.26; low quality evidence). One study (201 participants) showed that, overall, malignancies were less advanced in extensively tested participants than in participants in the control group. In total, 9/13 participants diagnosed with cancer in the extensively tested group had a T1 or T2 stage malignancy compared to 2/10 participants diagnosed with cancer in the control group (OR 5.00, 95% CI 1.05 to 23.76; P = 0.04; low quality evidence). There was no clear difference in detection of advanced stages between extensive tests versus tests at the physician's discretion: one participant in the extensively tested group had stage T3 compared with four participants in the control group (OR 0.25, 95% CI 0.03 to 2.28; P = 0.22; low quality evidence). In addition, extensively tested participants were diagnosed earlier than control group (mean: 1 month with extensive tests versus 11.6 months with tests at physician's discretion to cancer diagnosis from the time of diagnosis of VTE). Extensive testing did not increase the frequency of an underlying cancer diagnosis (OR 1.32, 95% CI 0.59 to 2.93; 396 participants; 2 studies; P = 0.50; low quality evidence). Neither study measured all-cause mortality, VTE-related morbidity and mortality, complications of anticoagulation, adverse effects of cancer tests, participant satisfaction or quality of life.When comparing standard testing plus PET/CT screening versus standard testing alone, standard testing plus PET/CT screening was consistent with either a benefit or no benefit on all-cause mortality (OR 1.22, 95% CI 0.49 to 3.04; 1248 participants; 2 studies; P = 0.66; moderate quality evidence), cancer-related mortality (OR 0.55, 95% CI 0.20 to 1.52; 1248 participants; 2 studies; P = 0.25; moderate quality evidence) or VTE-related morbidity (OR 1.02, 95% CI 0.48 to 2.17; 854 participants; 1 study; P = 0.96; moderate quality evidence). With regards to stage of cancer, there was no clear difference for detection of early (OR 1.78, 95% 0.51 to 6.17; 394 participants; 1 study; P = 0.37; low quality evidence) or advanced (OR 1.00, 95% CI 0.14 to 7.17; 394 participants; 1 study; P = 1.00; low quality evidence) stages of cancer. There was also no clear difference in the frequency of an underlying cancer diagnosis (OR 1.71, 95% CI 0.91 to 3.20; 1248 participants; 2 studies; P = 0.09; moderate quality evidence). Time to cancer diagnosis was 4.2 months in the standard testing group and 4.0 months in the standard testing plus PET/CT group (P = 0.88). Neither study measured VTE-related mortality, complications of anticoagulation, adverse effects of cancer tests, participant satisfaction or quality of life. Testing for cancer in people with unprovoked VTE may lead to earlier diagnosis of cancer at an earlier stage of the disease. However, there is currently insufficient evidence to draw definitive conclusions concerning the effectiveness of testing for undiagnosed cancer in people with a first episode of unprovoked VTE (DVT or PE) in reducing cancer and VTE-related morbidity and mortality. The results could be consistent with either benefit or no benefit. Further good-quality large-scale randomised controlled trials are required before firm conclusions can be made.

  13. Extensive bleeding during surgical treatment for gingival overgrowth in a patient on haemodialysis--a case report and review of the literature.

    PubMed

    Nishide, N; Nishikawa, T; Kanamura, N

    2005-12-01

    Before performing renal transplantation, a most important concern is to control any infection, including oral infections before transplantation. The bleeding diathesis of patients with uraemia is a significant clinical concern, especially when surgery is required. A 44-year-old female patient on haemodialysis was referred for evaluation of gingival overgrowth. The patient was planning a renal transplantation two months later. As the lesions were not considered successfully treatable before transplantation, a gingivectomy and teeth extraction was performed. In pre-operative examinations, an abnormal bleeding time was not detected and other coagulation tests were normal. Under general anaesthesia, 19 teeth were extracted and overgrown gingiva was removed. During the operation, extensive blood loss of 1650ml occurred and four units of concentrated red blood cells were transfused. This study suggests that patients with renal failure undergoing dental surgery require careful pre-surgical evaluation including assessment of their coagulation ability.

  14. Using Audience Response Devices for Extension Programming

    ERIC Educational Resources Information Center

    de Koff, Jason P.

    2013-01-01

    Audience response devices (ARDs), or "clickers," have traditionally been used in the classroom to take attendance, provide testing of current knowledge and knowledge gain, and assist with review of course topics. The ARDs were used at a recent Extension conference, which provided an opportunity to test how well this tool worked. Though…

  15. 77 FR 35464 - Modifications to the Disability Determination Procedures; Extension of Testing of Some Disability...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-13

    ...-772-1213 or TTY 1-800-325-0778, or visit our Internet site, Social Security Online, at http://www... SOCIAL SECURITY ADMINISTRATION [Docket No. SSA-2012-0029] Modifications to the Disability Determination Procedures; Extension of Testing of Some Disability Redesign Features AGENCY: Social Security...

  16. 78 FR 45010 - Modifications to the Disability Determination Procedures; Extension of Testing of Some Disability...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-25

    ...-772-1213 or TTY 1-800-325-0778, or visit our Internet site, Social Security Online, at http://www... SOCIAL SECURITY ADMINISTRATION [Docket No. SSA-2013-0030] Modifications to the Disability Determination Procedures; Extension of Testing of Some Disability Redesign Features AGENCY: Social Security...

  17. 78 FR 4120 - Notice of Request for Extension of Approval of an Information Collection; Tuberculosis Testing of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-18

    ... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2012-0098 ] Notice of Request for Extension of Approval of an Information Collection; Tuberculosis Testing of Imported Cattle From Mexico AGENCY: Animal and Plant Health Inspection Service, USDA. [[Page 4121

  18. Performance of Partially Fluorinated Polyimide Insulation for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Hammoud, Ahmad N.; Stavnes, Mark W.; Ide, James R.; Muegge, ED

    1995-01-01

    Polyimide has been used extensively as the primary wiring insulation in commercial planes, military aircraft, and space vehicles due to its low weight, high service temperature, and good dielectric strength. New failure modes, however, have been associated with the use of polyimide because of the susceptibility of the insulation to pyrolization and arc tracking. A new wiring construction utilizing partially fluorinated polyimide insulation has been tested and compared with the standard military polyimide wire. Electrical properties which were investigated include AC corona inception and extinction voltages (sea level and 60,000 feet), time/current to smoke, and wire fusing time. The two constructions were also characterized in terms of their mechanical properties including abrasion resistance, dynamic cut through, and notch propagation. These test efforts and the results obtained are presented and discussed.

  19. Performance of partially fluorinated polyimide insulation for aerospace applications

    NASA Astrophysics Data System (ADS)

    Hammoud, Ahmad N.; Stavnes, Mark W.; Ide, James R.; Muegge, Ed

    1995-08-01

    Polyimide has been used extensively as the primary wiring insulation in commercial planes, military aircraft, and space vehicles due to its low weight, high service temperature, and good dielectric strength. New failure modes, however, have been associated with the use of polyimide because of the susceptibility of the insulation to pyrolization and arc tracking. A new wiring construction utilizing partially fluorinated polyimide insulation has been tested and compared with the standard military polyimide wire. Electrical properties which were investigated include AC corona inception and extinction voltages (sea level and 60,000 feet), time/current to smoke, and wire fusing time. The two constructions were also characterized in terms of their mechanical properties including abrasion resistance, dynamic cut through, and notch propagation. These test efforts and the results obtained are presented and discussed.

  20. Reliability and validity of clinical tests to assess the anatomical integrity of the cervical spine in adults with neck pain and its associated disorders: Part 1-A systematic review from the Cervical Assessment and Diagnosis Research Evaluation (CADRE) Collaboration.

    PubMed

    Lemeunier, Nadège; da Silva-Oolup, S; Chow, N; Southerst, D; Carroll, L; Wong, J J; Shearer, H; Mastragostino, P; Cox, J; Côté, E; Murnaghan, K; Sutton, D; Côté, P

    2017-09-01

    To determine the reliability and validity of clinical tests to assess the anatomical integrity of the cervical spine in adults with neck pain and its associated disorders. We updated the systematic review of the 2000-2010 Bone and Joint Decade Task Force on Neck Pain and its Associated Disorders. We also searched the literature to identify studies on the reliability and validity of Doppler velocimetry for the evaluation of cervical arteries. Two independent reviewers screened and critically appraised studies. We conducted a best evidence synthesis of low risk of bias studies and ranked the phases of investigations using the classification proposed by Sackett and Haynes. We screened 9022 articles and critically appraised 8 studies; all 8 studies had low risk of bias (three reliability and five validity Phase II-III studies). Preliminary evidence suggests that the extension-rotation test may be reliable and has adequate validity to rule out pain arising from facet joints. The evidence suggests variable reliability and preliminary validity for the evaluation of cervical radiculopathy including neurological examination (manual motor testing, dermatomal sensory testing, deep tendon reflexes, and pathological reflex testing), Spurling's and the upper limb neurodynamic tests. No evidence was found for doppler velocimetry. Little evidence exists to support the use of clinical tests to evaluate the anatomical integrity of the cervical spine in adults with neck pain and its associated disorders. We found preliminary evidence to support the use of the extension-rotation test, neurological examination, Spurling's and the upper limb neurodynamic tests.

  1. Modeling along-axis variations in fault architecture in the Main Ethiopian Rift: implications for Nubia-Somalia kinematics

    NASA Astrophysics Data System (ADS)

    Erbello, Asfaw; Corti, Giacomo; Sani, Federico; Kidane, Tesfaye

    2016-04-01

    The Main Ethiopian Rift (MER), at the northern termination of the East African Rift, is an ideal locale where to get insights into the long-term motion between Nubia and Somalia. The rift is indeed one of the few places along the plate boundary where the deformation is narrow: its evolution is thus strictly related to the kinematics of the two major plates, whereas south of the Turkana depression a two-plate model for the EARS is too simplistic as extension occurs both along the Western and Eastern branches and different microplates are present between the two major plates. Despite its importance, the kinematics responsible for development and evolution of the MER is still a matter of debate: indeed, whereas the Quaternary-present kinematics of rifting is rather well constrained, the plate kinematics driving the initial, Mio-Pliocene stages of extension is still not clear, and different hypothesis have been put forward, including: polyphase rifting, with a change in direction of extension from NW-SE extension to E-W extension; constant Miocene-recent NW-SE extension; constant Miocene-recent NE-SW extension; constant, post-11 Ma extension consistent with the GPS-derived kinematics (i.e., roughly E-W to ESE-WNW). To shed additional light on this controversy and to test these different hypothesis, in this contribution we use new crustal-scale analogue models to analyze the along-strike variations in fault architecture in the MER and their relations with the rift trend, plate motion and the resulting Miocene-recent kinematics of rifting. The extension direction is indeed one of the most important parameters controlling the architecture of continental rifts and the relative abundance and orientation of different fault sets that develop during oblique rifting is typically a function of the angle between the extension direction and the orthogonal to the rift trend (i.e., the obliquity angle). Since the trend of the MER varies along strike, and consequently it is characterized by a variable obliquity angle (i.e., kinematics) along its length, the analysis of fault architecture and its variations are able to provide significant insights into the plate kinematics responsible for rift development and evolution. Our models thus reproduce the overall geometry of the ~600km-long MER with its along-strike variation in orientation to test the above-described hypothesis of rift evolution. Analysis of model results in terms of statistics of fault length and orientation, and deformation architecture and its comparison with the MER suggests that rift has likely developed under a constant, post-11 Ma extension oriented roughly E-W (N97.5°E), consistent with recent plate kinematics models.

  2. Validity, Reliability, and Performance Determinants of a New Job-Specific Anaerobic Work Capacity Test for the Norwegian Navy Special Operations Command.

    PubMed

    Angeltveit, Andreas; Paulsen, Gøran; Solberg, Paul A; Raastad, Truls

    2016-02-01

    Operators in Special Operation Forces (SOF) have a particularly demanding profession where physical and psychological capacities can be challenged to the extremes. The diversity of physical capacities needed depend on the mission. Consequently, tests used to monitor SOF operators' physical fitness should cover a broad range of physical capacities. Whereas tests for strength and aerobic endurance are established, there is no test for specific anaerobic work capacity described in the literature. The purpose of this study was therefore to evaluate the reliability, validity, and to identify performance determinants of a new test developed for testing specific anaerobic work capacity in SOF operators. Nineteen active young students were included in the concurrent validity part of the study. The students performed the evacuation (EVAC) test 3 times and the results were compared for reliability and with performance in the Wingate cycle test, 300-m sprint, and a maximal accumulated oxygen deficit (MAOD) test. In part II of the study, 21 Norwegian Navy Special Operations Command operators conducted the EVAC test, anthropometric measurements, a dual x-ray absorptiometry scan, leg press, isokinetic knee extensions, maximal oxygen uptake test, and countermovement jump (CMJ) test. The EVAC test showed good reliability after 1 familiarization trial (intraclass correlation = 0.89; coefficient of variance = 3.7%). The EVAC test correlated well with the Wingate test (r = -0.68), 300-m sprint time (r = 0.51), and 300-m mean power (W) (r = -0.67). No significant correlation was found with the MAOD test. In part II of the study, height, body mass, lean body mass, isokinetic knee extension torque, maximal oxygen uptake, and maximal power in a CMJ was significantly correlated with performance in the EVAC test. The EVAC test is a reliable and valid test for anaerobic work capacity for SOF operators, and muscle mass, leg strength, and leg power seem to be the most important determinants of performance.

  3. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength.

    PubMed

    Douma, K W; Regterschot, G R H; Krijnen, W P; Slager, G E C; van der Schans, C P; Zijlstra, W

    2016-01-01

    The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for application in various clinical settings, however, its capability to detect changes in muscle force over time is limited but comparable to existing instruments.

  4. SlicerRT: radiation therapy research toolkit for 3D Slicer.

    PubMed

    Pinter, Csaba; Lasso, Andras; Wang, An; Jaffray, David; Fichtinger, Gabor

    2012-10-01

    Interest in adaptive radiation therapy research is constantly growing, but software tools available for researchers are mostly either expensive, closed proprietary applications, or free open-source packages with limited scope, extensibility, reliability, or user support. To address these limitations, we propose SlicerRT, a customizable, free, and open-source radiation therapy research toolkit. SlicerRT aspires to be an open-source toolkit for RT research, providing fast computations, convenient workflows for researchers, and a general image-guided therapy infrastructure to assist clinical translation of experimental therapeutic approaches. It is a medium into which RT researchers can integrate their methods and algorithms, and conduct comparative testing. SlicerRT was implemented as an extension for the widely used 3D Slicer medical image visualization and analysis application platform. SlicerRT provides functionality specifically designed for radiation therapy research, in addition to the powerful tools that 3D Slicer offers for visualization, registration, segmentation, and data management. The feature set of SlicerRT was defined through consensus discussions with a large pool of RT researchers, including both radiation oncologists and medical physicists. The development processes used were similar to those of 3D Slicer to ensure software quality. Standardized mechanisms of 3D Slicer were applied for documentation, distribution, and user support. The testing and validation environment was configured to automatically launch a regression test upon each software change and to perform comparison with ground truth results provided by other RT applications. Modules have been created for importing and loading DICOM-RT data, computing and displaying dose volume histograms, creating accumulated dose volumes, comparing dose volumes, and visualizing isodose lines and surfaces. The effectiveness of using 3D Slicer with the proposed SlicerRT extension for radiation therapy research was demonstrated on multiple use cases. A new open-source software toolkit has been developed for radiation therapy research. SlicerRT can import treatment plans from various sources into 3D Slicer for visualization, analysis, comparison, and processing. The provided algorithms are extensively tested and they are accessible through a convenient graphical user interface as well as a flexible application programming interface.

  5. Design and testing of an energy-absorbing crewseat for the F/FB-111 aircraft. Volume 3: Data from crew module testing

    NASA Technical Reports Server (NTRS)

    Shane, S. J.

    1985-01-01

    Over the past years, several papers and reports have documented the unacceptably high injury rate during the escape sequence (including the ejection and ground impact) of the crew module for F/FB-111 aircraft. This report documents a program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats. An energy absorbing test seat was designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions, was conducted at a sled test facility. Comparative tests with operational F-111 crewseats were also conducted. After successful dynamic testing of the seat, more testing was conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests werre conducted. The vertical drop tests were used to obtain comparative data between the energy absorbing and operational seats.

  6. Seroprevalence of Toxoplasma gondii in Iberian pig sows.

    PubMed

    Pablos-Tanarro, Alba; Ortega-Mora, Luis Miguel; Palomo, Antonio; Casasola, Francisco; Ferre, Ignacio

    2018-05-01

    The objective of the present study was to investigate the seroprevalence of Toxoplasma gondii infection in Iberian sows reared in extensive and intensive management conditions and to compare two serologic techniques used for diagnosis. In addition, some possible risk factors associated with the presence of serum antibodies to T. gondii were also studied. Serum samples were collected from 2492 Iberian sows on 14 pig farms. Three types of management systems were included, traditional extensive outdoor farms (five farms), intensive farms with outdoor access (n = 4), and conventional intensive indoor farms (n = 5). The presence of serum antibodies to T. gondii was evaluated by two commercially available tests: an indirect enzyme-linked immunosorbent assay (ELISA) and a direct agglutination test (DAT). Serum antibodies against T. gondii were detected in 237 sows (9.5%) by at least one of the techniques used. The mean seroprevalence of toxoplasmosis in Iberian sows was 5.8% by ELISA and 8.9% by DAT. An agreement kappa-value of 0.68 (95%, CI = 0.63-0.74) was found between both tests. The results from this study suggest that the prevalence of T. gondii antibodies among Iberian sows seems to be moderate-low. The presence of serum antibodies against T. gondii in Iberian sows was associated to an extensive management system and low-level facilities of the farm, sow number (> 1000 animals), presence of cats, absence of rodent control and bird-proof nets in windows, well-water source, feed sources and storage (from the same farm and not stored in silo), absence of fences, and low farm worker qualification.

  7. Translating exercise interventions to an in-home setting for seniors: preliminary impact on physical activity and function.

    PubMed

    Dondzila, Christopher J; Swartz, Ann M; Keenan, Kevin G; Harley, Amy E; Azen, Razia; Strath, Scott J

    2016-12-01

    The purpose of this study is to investigate whether an in-home, individually tailored intervention is efficacious in promoting increases in physical activity (PA) and improvements in physical functioning (PF) in low-active older adults. Participants were randomized to two groups for the 8-week intervention. The enhanced physical activity (EPA) group received individualized exercise programming, including personalized step goals and a resistance band training program, and the standard of care (SoC) group received a general activity goal. Pre- and post-intervention PF measures included choice step reaction time, knee extension/flexion strength, hand grip strength, and 8 ft up and go test completion time. Thirty-nine subjects completed this study (74.6 ± 6.4 years). Significant increases in steps/day were observed for both the EPA and SoC groups, although the improvements in the EPA group were significantly higher when including only those who adhered to weekly step goals. Both groups experienced significant PF improvements, albeit greater in the EPA group for the 8 ft up and go test and knee extension strength. A low cost, in-home intervention elicited improvements in both PA and PF. Future research is warranted to expand upon the size and scope of this study, exploring dose thresholds (and time frames) for PA to improve PF and strategies to further bolster adherence rates to maximize intervention benefits.

  8. Initial Investigation into the Psychoacoustic Properties of Small Unmanned Aerial System Noise

    NASA Technical Reports Server (NTRS)

    Christian, Andrew; Cabell, Randolph

    2017-01-01

    For the past several years, researchers at NASA Langley have been engaged in a series of projects to study the degree to which existing facilities and capabilities, originally created for work on full-scale aircraft, are extensible to smaller scales --those of the small unmanned aerial systems (sUAS, also UAVs and, colloquially, `drones') that have been showing up in the nation's airspace of late. This paper follows an e ort that has led to an initial human{subject psychoacoustic test regarding the annoyance generated by sUAS noise. This e ort spans three phases: 1. The collection of the sounds through field recordings. 2. The formulation and execution of a psychoacoustic test using those recordings. 3. The initial analysis of the data from that test. The data suggests a lack of parity between the noise of the recorded sUAS and that of a set of road vehicles that were also recorded and included in the test, as measured by a set of contemporary noise metrics. Future work, including the possibility of further human subject testing, is discussed in light of this suggestion.

  9. Functional Performance Testing and Patient Reported Outcomes following ACL Reconstruction: A Systematic Scoping Review

    PubMed Central

    Herrington, Lee

    2014-01-01

    Objective. A systematic scoping review of the literature to identify functional performance tests and patient reported outcomes for patients who undergo anterior cruciate ligament (ACL) reconstruction and rehabilitation that are used in clinical practice and research during the last decade. Methods. A literature search was conducted. Electronic databases used included Medline, PubMed, Cochrane Library, EMBASE, CINAHL, SPORTDiscus, PEDro, and AMED. The inclusion criteria were English language, publication between April 2004 and April 2014, and primary ACL reconstruction with objective and/or subjective outcomes used. Two authors screened the selected papers for title, abstract, and full-text in accordance with predefined inclusion and exclusion criteria. The methodological quality of all papers was assessed by a checklist of the Critical Appraisal Skills Programme (CASP). Results. A total of 16 papers were included with full-text. Different authors used different study designs for functional performance testing which led to different outcomes that could not be compared. All papers used a measurement for quantity of functional performance except one study which used both quantity and quality outcomes. Several functional performance tests and patient reported outcomes were identified in this review. Conclusion. No extensive research has been carried out over the past 10 years to measure the quality of functional performance testing and control stability of patients following ACL reconstruction. However this study found that the measurement of functional performance following ACL reconstruction consisting of a one-leg hop for a set distance or a combination of different hops using limb symmetry index (LSI) was a main outcome parameter of several studies. A more extensive series of tests is suggested to measure both the quantitative and qualitative aspects of functional performance after the ACL reconstruction. The KOOS and the IKDC questionnaires are both measures that are increasingly being used for ACL reconstruction throughout the last decade. PMID:27379330

  10. A simulation study of spine biofidelity in the hybrid-III 6-year-old ATD.

    PubMed

    Wu, Jun; Cao, Libo; Reed, Matthew P; Hu, Jingwen

    2013-01-01

    Because of the lack of pediatric biomechanical data, Hybrid-III (HIII) child anthropomorphic test devices (ATDs) are essentially scaled from the mid-size male ATD based on the geometric considerations. These ATDs inherit a rigid thoracic spine from the adult HIII ATDs, which has been criticized as unrealistic. Therefore, the objective of this study was to explore possible design modifications for improving the spine biofidelity of the HIII 6-year-old ATD. A previously developed and validated HIII 6-year-old MADYMO ATD model was used as the baseline model to investigate the effects of design modifications on the spine biofidelity of the current ATD. Several sets of child volunteer and cadaver test data were considered as the design targets, including child volunteer low-speed crash test data, pediatric cadaver cervical spine tensile test data, and child cadaver crash test data. ATD design modifications include adding an additional joint to the thoracic spine region and changing the joint characteristics at the cervical and lumbar spine regions. Optimization techniques were used to match simulation results to each set of test results. The results indicate that the translational characteristics of the cervical and lumbar spine in the current child ATD need to be reduced to achieve realistic spine flexibility. Adding an additional joint at the thoracic spine region with degree of freedom in both flexion/extension and tension would significantly improve the ATD biofidelity in terms of predicting the overall spine curvature and head excursion in frontal crashes. Future ATD spine modification should focus on reducing the neck and lumbar tension stiffness and adding additional flexibility both in flexion/extension and tension at the thoracic spine region. The child ATD model developed in this study can be used as an important tool to improve child ATD biofidelity and child restraint system design in motor vehicle crashes.

  11. Slow crack growth test method for polyethylene gas pipes. Volume 1. Topical report, December 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leis, B.; Ahmad, J.; Forte, T.

    1992-12-01

    In spite of the excellent performance record of polyethylene (PE) pipes used for gas distribution, a small number of leaks occur in distribution systems each year because of slow growth of cracks through pipe walls. The Slow Crack Growth Test (SCG) has been developed as a key element in a methodology for the assessment of the performance of polyethylene gas distribution systems to resist such leaks. This tropical report describes work conducted in the first part of the research directed at the initial development of the SCG test, including a critical evaluation of the applicability of the SCG test asmore » an element in PE gas pipe system performance methodology. Results of extensive experiments and analysis are reported. The results show that the SCG test should be very useful in performance assessment.« less

  12. Evaluation of coated columbium test panels having application to a secondary nozzle extension for the RL10 rocket engine system, parts 1 and 2

    NASA Technical Reports Server (NTRS)

    Murphy, Kenneth S.; Castro, Joaquin H.

    1988-01-01

    The activity performed on the screening and evaluation of various coatings for application on columbium alloy test panels representative of a radiation-cooled nozzle extension for the RL10 rocket engine is summarized. Vendors and processes of candidate coatings were evaluated. Post engine test evaluations of the two selected coatings are discussed.

  13. Orbital Express Advanced Video Guidance Sensor: Ground Testing, Flight Results and Comparisons

    NASA Technical Reports Server (NTRS)

    Pinson, Robin M.; Howard, Richard T.; Heaton, Andrew F.

    2008-01-01

    Orbital Express (OE) was a successful mission demonstrating automated rendezvous and docking. The 2007 mission consisted of two spacecraft, the Autonomous Space Transport Robotic Operations (ASTRO) and the Next Generation Serviceable Satellite (NEXTSat) that were designed to work together and test a variety of service operations in orbit. The Advanced Video Guidance Sensor, AVGS, was included as one of the primary proximity navigation sensors on board the ASTRO. The AVGS was one of four sensors that provided relative position and attitude between the two vehicles. Marshall Space Flight Center was responsible for the AVGS software and testing (especially the extensive ground testing), flight operations support, and analyzing the flight data. This paper briefly describes the historical mission, the data taken on-orbit, the ground testing that occurred, and finally comparisons between flight data and ground test data for two different flight regimes.

  14. Comprehensive Carrier Screening and Molecular Diagnostic Testing for Recessive Childhood Diseases

    PubMed Central

    Kingsmore, Stephen

    2012-01-01

    Of 7,028 disorders with suspected Mendelian inheritance, 1,139 are recessive and have an established molecular basis. Although individually uncommon, Mendelian diseases collectively account for ~20% of infant mortality and ~18% of pediatric hospitalizations. Molecular diagnostic testing is currently available for only ~300 recessive disorders. Preconception screening, together with genetic counseling of carriers, has resulted in remarkable declines in the incidence of several severe recessive diseases including Tay-Sachs disease and cystic fibrosis. However, extension of preconception screening and molecular diagnostic testing to most recessive disease genes has hitherto been impractical. Recently, we reported a preconception carrier screen / molecular diagnostic test for 448 recessive childhood diseases. The current status of this test is reviewed here. Currently, this reports analytical validity of the comprehensive carrier test. As the clinical validity and clinical utility in the contexts described is ascertained, this article will be updated. PMID:22872815

  15. Space Operations Center system analysis study extension. Volume 4, book 1: SOC system analysis report

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The Space Operations Center (SOC) orbital space station missions are analyzed. Telecommunications missions, space science, Earth sensing, and space testing missions, research and applications missions, defense missions, and satellite servicing missions are modeled and mission needs discussed. The satellite servicing missions are analyzed in detail, including construction and servicing equipment requirements, mission needs and benefits, differential drag characteristics of co-orbiting satellites, and satellite servicing transportation requirements.

  16. The electromagnetic environment in CFC structures

    NASA Technical Reports Server (NTRS)

    Hardwick, C. J.; Haigh, S. J.

    1991-01-01

    Extensive measurements of induced voltages and currents were made using a CFC (carbon fiber composites) horizontal stabilizer from the A320 as a test bed. The work was done to investigate the efficacy of various protection schemes to reduce the magnitudes of the induced voltages and validate a computer program INDCAL. Results indicate that a good understanding of the various induced voltage mechanisms including the long wave effect due to current redistribution was obtained.

  17. Arcjet thruster research and technology, phase 2

    NASA Technical Reports Server (NTRS)

    Yano, Steve E.

    1991-01-01

    The principle objective of Phase 2 was to produce an engineering model N2H4 arcjet system which met typical performance, lifetime, environmental, and interface specifications required to support a 10-year N-S stationkeeping mission for a communications spacecraft. The system includes an N2H4 arcjet thruster, power conditioning unit (PCU), and the interconnecting power cable assembly. This objective was met with the successful conclusion of an extensive system test series.

  18. The Soviet Military Leadership and the Question of Soviet Deployment Retreats

    DTIC Science & Technology

    1988-11-01

    change, within Project AIR FORCE’s National Security Strategies Program. Earlier studies published in this project include: Jeremy R. Azrael, The...of a weapon system inherited from thi past for the sake of anticipated tradeoffs, notably in disruptive effecfs on the Western alliance. Anticipation...extensively test what the market will bear in negotiation with the West. - The second largest Soviet conventional force deployments are in Siberia and the

  19. Single scattering from nonspherical Chebyshev particles: A compendium of calculations

    NASA Technical Reports Server (NTRS)

    Wiscombe, W. J.; Mugnai, A.

    1986-01-01

    A large set of exact calculations of the scattering from a class of nonspherical particles known as Chebyshev particles' has been performed. Phase function and degree of polarization in random orientation, and parallel and perpendicular intensities in fixed orientations, are plotted for a variety of particles shapes and sizes. The intention is to furnish a data base against which both experimental data, and the predictions of approximate methods, can be tested. The calculations are performed with the widely-used Extended Boundary Condition Method. An extensive discussion of this method is given, including much material that is not easily available elsewhere (especially the analysis of its convergence properties). An extensive review is also given of all extant methods for nonspherical scattering calculations, as well as of the available pool of experimental data.

  20. Aircraft scatterometer observations of soil moisture on rangeland watersheds

    NASA Technical Reports Server (NTRS)

    Jackson, T. J.; Oneill, P. E.

    1983-01-01

    Extensive studies conducted by several researchers using truck-mounted active microwave sensors have shown the sensitivity of these sensors to soil moisture variations. The logical extension of these results is the evaluation of similar systems at lower resolutions typical of operational systems. Data collected during a series of aircraft flights in 1978 and 1980 over four rangeland watersheds located near Chickasha, Oklahoma, were analyzed in this study. These data included scatterometer measurements made at 1.6 and 4.75 GHz using a NASA aircraft and ground observations of soil moisture for a wide range of moisture conditions. Data were analyzed for consistency and compared to previous truck and aircraft results. Results indicate that the sensor system is capable of providing consistent estimates of soil moisture under the conditions tested.

  1. High-Speed Cycling Intervention Improves Rate-Dependent Mobility in Older Adults

    PubMed Central

    Bellumori, Maria; Uygur, Mehmet; Knight, Christopher A.

    2016-01-01

    PURPOSE The aim was to determine the feasibility of a six-week speed-based exercise program that could be used to initiate new exercise behaviors and improve rapid movement in older adults approaching frailty. METHODS The intervention group included 14 older adults (3 males, 11 females, mean (SD) age: 70 (7.6) years, height: 1.6 (.11) m, mass: 76.8 (12.0) kg, BMI: 27.7(4.7)). The control group included 12 older adults (6 males, 6 females, mean (SD) age: 69.2 (6.9) years, height: 1.7 (.09) m, mass: 78.2 (10.9) kg, BMI: 25.3 (2.7)). Subjects included active older adults, including regular exercisers, but none were engaged in sports or exercises with an emphasis on speed (e.g. cycling spin classes or tennis). Stationary recumbent cycling was selected to minimize fall risk and low pedaling resistance reduced musculoskeletal and cardiovascular load. Two weekly 30-minute exercise sessions consisted of interval training in which subjects pedaled at preferred cadence and performed ten 20-s fast cadence intervals separated by 40-s of active recovery at preferred cadence. RESULTS Significant Group by Time interactions (p<.05) supported a 2-s improvement in the timed up and go test and a 34% improvement in rapid isometric knee extension contractions in the exercise group but not in controls. Central neural adaptations are suggested because this lower extremity exercise program also elicited significant improvements in the untrained upper extremities of the exercise group (elbow extension RFD-SF and 9-Hole Peg Test, p<.05). CONCLUSION These results demonstrate that a relatively low dose of speed-based exercise can improve neuromuscular function and tests of mobility in older adults. Such a program serves as a sensible precursor to subsequent, more vigorous training or as an adjunct to a program where a velocity emphasis is lacking. PMID:27501360

  2. LIVVkit: An extensible, python-based, land ice verification and validation toolkit for ice sheet models

    NASA Astrophysics Data System (ADS)

    Kennedy, Joseph H.; Bennett, Andrew R.; Evans, Katherine J.; Price, Stephen; Hoffman, Matthew; Lipscomb, William H.; Fyke, Jeremy; Vargo, Lauren; Boghozian, Adrianna; Norman, Matthew; Worley, Patrick H.

    2017-06-01

    To address the pressing need to better understand the behavior and complex interaction of ice sheets within the global Earth system, significant development of continental-scale, dynamical ice sheet models is underway. Concurrent to the development of the Community Ice Sheet Model (CISM), the corresponding verification and validation (V&V) process is being coordinated through a new, robust, Python-based extensible software package, the Land Ice Verification and Validation toolkit (LIVVkit). Incorporated into the typical ice sheet model development cycle, it provides robust and automated numerical verification, software verification, performance validation, and physical validation analyses on a variety of platforms, from personal laptops to the largest supercomputers. LIVVkit operates on sets of regression test and reference data sets, and provides comparisons for a suite of community prioritized tests, including configuration and parameter variations, bit-for-bit evaluation, and plots of model variables to indicate where differences occur. LIVVkit also provides an easily extensible framework to incorporate and analyze results of new intercomparison projects, new observation data, and new computing platforms. LIVVkit is designed for quick adaptation to additional ice sheet models via abstraction of model specific code, functions, and configurations into an ice sheet model description bundle outside the main LIVVkit structure. Ultimately, through shareable and accessible analysis output, LIVVkit is intended to help developers build confidence in their models and enhance the credibility of ice sheet models overall.

  3. Isokinetic Extension Strength Is Associated With Single-Leg Vertical Jump Height

    PubMed Central

    Fischer, Felix; Blank, Cornelia; Dünnwald, Tobias; Gföller, Peter; Herbst, Elmar; Hoser, Christian; Fink, Christian

    2017-01-01

    Background: Isokinetic strength testing is an important tool in the evaluation of the physical capacities of athletes as well as for decision making regarding return to sports after anterior cruciate ligament (ACL) reconstruction in both athletes and the lay population. However, isokinetic testing is time consuming and requires special testing equipment. Hypothesis: A single-jump test, regardless of leg dominance, may provide information regarding knee extension strength through the use of correlation analysis of jump height and peak torque of isokinetic muscle strength. Study Design: Cross-sectional study; Level of evidence, 3. Methods: A total of 169 patients who underwent ACL reconstruction were included in this study. Isokinetic testing was performed on the injured and noninjured legs. Additionally, a single-leg countermovement jump was performed to assess jump height using a jump accelerometer sensor. Extension strength values were used to assess the association between isokinetic muscle strength and jump height. Results: The sample consisted of 60 female (mean age, 20.8 ± 8.3 years; mean weight, 61.7 ± 6.5 kg; mean height, 167.7 ± 5.3 cm) and 109 male (mean age, 23.2 ± 7.7 years; mean weight, 74.6 ± 10.2 kg; mean height, 179.9 ± 6.9 cm) patients. Bivariate correlation analysis showed an association (r = 0.56, P < .001) between jump height and isokinetic extension strength on the noninvolved side as well as an association (r = 0.52, P < .001) for the involved side. Regression analysis showed that in addition to jump height (beta = 0.49, P < .001), sex (beta = –0.17, P = .008) and body mass index (beta = 0.37, P < .001) affected isokinetic strength. The final model explained 51.1% of the variance in isokinetic muscle strength, with jump height having the strongest impact (beta = 0.49, P < .001) and explaining 31.5% of the variance. Conclusion: Initial analysis showed a strong association between isokinetic strength and jump height. The study population encompassed various backgrounds, skill levels, and activity profiles, which might have affected the outcome. Even after controlling for age and sex, isokinetic strength was still moderately associated with jump height. Therefore, the jump technique and type of sport should be considered in future research. PMID:29147670

  4. 78 FR 52128 - Cotton Classing, Testing and Standards: Notice of Request for an Extension and Revision to a...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-22

    ... DEPARTMENT OF AGRICULTURE Agricultural Marketing Service [AMS-CN-13-0044] Cotton Classing, Testing..., for an extension and revision to the currently approved information collection entitled Cotton... proposal to: Shethir M. Riva, Chief, Research and Promotion Staff, Cotton and Tobacco Programs, AMS, USDA...

  5. 78 FR 5430 - Extension of Approval Period for Certain Tests Used in the National Reporting System for Adult...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-25

    ... DEPARTMENT OF EDUCATION Extension of Approval Period for Certain Tests Used in the National Reporting System for Adult Education AGENCY: Office of Vocational and Adult Education, Department of... National Reporting System for Adult Education (NRS regulations) (73 FR 2306). The NRS regulations...

  6. 76 FR 19902 - Energy Conservation Program for Consumer Products: Decision and Order Granting 180-Day Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-11

    ... for Residential Furnaces and Boilers Test Procedure Amendments; Correction AGENCY: Office of Energy..., 2011), a 180-day extension of the compliance date for recent amendments to the DOE test procedure for... DOE received this petition well after February 17, 2011, the Department believes a number of factors...

  7. Cockpit integration from a pilot's point of view

    NASA Technical Reports Server (NTRS)

    Green, D. L.

    1982-01-01

    Extensive experience in both operational and engineering test flight was used to suggest straightforward changes to helicopter cockpit and control system design that would improve pilot performance in marginal and instrument flight conditions. Needed control system improvements considered include: (1) separation of yaw from cyclic force trim; (2) pedal force proportional to displacement rate; and (3) integration of engine controls in collective stick. Display improvements needed include: (1) natural cuing of yaw rate in attitude indicator; (2) collective position indication and radar altimeter placed within primary scan; and (3) omnidirectional display of full range airspeed data.

  8. Heavy-section steel technology program. Semiannual progress report for period ending February 28, 1973

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1974-02-01

    The materials investigations under the HSST program are divided into studies of unirradiated materials and studies of irradiation effects. The studies of unirradiated materials, which include inspection, characterization, metallurgy, variability determinations, transition temperature investigations, fracture mechanics studies, and fatigue-crack propagation tests, are discussed. The investigations of irradiated materials include studies of radiation effects on A-533-B steel. Results of studies on thick pressure vessels and pipes of ASTM A508 steel are also reported along with results of studies on Mode III crack extension in reactor piping. (JRD)

  9. Correlation between extension-block K-wire insertion angle and postoperative extension loss in mallet finger fracture.

    PubMed

    Lee, S K; Kim, Y H; Moon, K H; Choy, W S

    2018-02-01

    Extension-block pinning represents a simple and reliable surgical technique. Although this procedure is commonly performed successfully, some patients develop postoperative extension loss. To date, the relationship between extension-block Kirschner wire (K-wire) insertion angle and postoperative extension loss in mallet finger fracture remains unclear. We aimed to clarify this relationship and further evaluate how various operative and non-operative factors affect postoperative extension loss after extension-block pinning for mallet finger fracture. A retrospective study was conducted to investigate a relationship between extension block K-wire insertion angle and postoperative extension loss. The inclusion criteria were: (1) a dorsal intra-articular fracture fragment involving 30% of the base of the distal phalanx with or without volar subluxation of the distal phalanx; and (2) <3 weeks delay from the injury without treatment. Extension-block K-wire insertion angle and fixation angle of the distal interphalangeal (DIP) joint were assessed using lateral radiograph at immediate postoperative time. Postoperative extension loss was assessed by using lateral radiograph at latest follow-up. Extension-block K-wire insertion angle was defined as the acute angle between extension block K-wire and longitudinal axis of middle phalangeal head. DIP joint fixation angle was defined as the acute angle between the distal phalanx and middle phalanx longitudinal axes. Seventy-five patients were included. The correlation analysis revealed that extension-block K-wire insertion angle had a negative correlation with postoperative extension loss, whereas fracture size and time to operation had a positive correlation (correlation coefficient for extension block K-wire angle: -0.66, facture size: +0.67, time to operation: +0.60). When stratifying patients in terms of negative and positive fixation angle of the DIP joint, the independent t-test showed that mean postoperative extension loss is -3.67° and +4.54° (DIP joint fixation angles of <0° and ≥0°, respectively, P=0.024). When stratifying patients in terms of extension-block K-wire insertion angle (30°, 30°-40°, >40°), ANOVA showed significantly less postoperative extension loss for higher insertion angles (>40°) than for medium insertion angles (30°-40°). Mean postoperative extension loss difference between higher insertion angle (>40°) and medium insertion angle (30°-40°) was 11° (P=0.002). Using an insertion angle of the extension-block K-wire of 40°-45° and a slightly hyperextended position of the DIP joint may help reducing postoperative extension loss. Therapeutic level III. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. 30 CFR 27.11 - Extension of certification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Extension of certification. 27.11 Section 27.11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS General Provisions § 27.11 Extension of...

  11. 30 CFR 27.11 - Extension of certification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Extension of certification. 27.11 Section 27.11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS General Provisions § 27.11 Extension of...

  12. Does change in isolated lumbar extensor muscle function correlate with good clinical outcome? A secondary analysis of data on change in isolated lumbar extension strength, pain, and disability in chronic low back pain.

    PubMed

    Steele, James; Fisher, James; Perrin, Craig; Conway, Rebecca; Bruce-Low, Stewart; Smith, Dave

    2018-01-12

    Secondary analysis of data from studies utilising isolated lumbar extension exercise interventions for correlations among changes in isolated lumbar extension strength, pain, and disability. Studies reporting isolated lumbar extension strength changes were examined for inclusion criteria including: (1) participants with chronic low back pain, (2) intervention ≥ four weeks including isolated lumbar extension exercise, (3) outcome measures including isolated lumbar extension strength, pain (Visual Analogue Scale), and disability (Oswestry Disability Index). Six studies encompassing 281 participants were included. Correlations among change in isolated lumbar extension strength, pain, and disability. Participants were grouped as "met" or "not met" based on minimal clinically important changes and between groups comparisons conducted. Isolated lumbar extension strength and Visual Analogue Scale pooled analysis showed significant weak to moderate correlations (r = -0.391 to -0.539, all p < 0.001). Isolated lumbar extension strength and Oswestry Disability Index pooled analysis showed significant weak correlations (r = -0.349 to -0.470, all p < 0.001). For pain and disability, isolated lumbar extension strength changes were greater for those "met" compared with those "not met" (p < 0.001-0.008). Improvements in isolated lumbar extension strength may be related to positive and meaningful clinical outcomes. As many other performance outcomes and clinical outcomes are not related, isolated lumbar extension strength change may be a mechanism of action affecting symptom improvement. Implications for Rehabilitation Chronic low back pain is often associated with deconditioning of the lumbar extensor musculature. Isolated lumbar extension exercise has been shown to condition this musculature and also reduce pain and disability. This study shows significant correlations between increases in isolated lumbar extension strength and reductions in pain and disability. Strengthening of the lumbar extensor musculature could be considered an important target for exercise interventions.

  13. Test Program for Stirling Radioisotope Generator Hardware at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Lewandowski, Edward J.; Bolotin, Gary S.; Oriti, Salvatore M.

    2015-01-01

    Stirling-based energy conversion technology has demonstrated the potential of high efficiency and low mass power systems for future space missions. This capability is beneficial, if not essential, to making certain deep space missions possible. Significant progress was made developing the Advanced Stirling Radioisotope Generator (ASRG), a 140-W radioisotope power system. A variety of flight-like hardware, including Stirling convertors, controllers, and housings, was designed and built under the ASRG flight development project. To support future Stirling-based power system development NASA has proposals that, if funded, will allow this hardware to go on test at the NASA Glenn Research Center. While future flight hardware may not be identical to the hardware developed under the ASRG flight development project, many components will likely be similar, and system architectures may have heritage to ASRG. Thus, the importance of testing the ASRG hardware to the development of future Stirling-based power systems cannot be understated. This proposed testing will include performance testing, extended operation to establish an extensive reliability database, and characterization testing to quantify subsystem and system performance and better understand system interfaces. This paper details this proposed test program for Stirling radioisotope generator hardware at NASA Glenn. It explains the rationale behind the proposed tests and how these tests will meet the stated objectives.

  14. Test Program for Stirling Radioisotope Generator Hardware at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Lewandowski, Edward J.; Bolotin, Gary S.; Oriti, Salvatore M.

    2014-01-01

    Stirling-based energy conversion technology has demonstrated the potential of high efficiency and low mass power systems for future space missions. This capability is beneficial, if not essential, to making certain deep space missions possible. Significant progress was made developing the Advanced Stirling Radioisotope Generator (ASRG), a 140-watt radioisotope power system. A variety of flight-like hardware, including Stirling convertors, controllers, and housings, was designed and built under the ASRG flight development project. To support future Stirling-based power system development NASA has proposals that, if funded, will allow this hardware to go on test at the NASA Glenn Research Center (GRC). While future flight hardware may not be identical to the hardware developed under the ASRG flight development project, many components will likely be similar, and system architectures may have heritage to ASRG. Thus the importance of testing the ASRG hardware to the development of future Stirling-based power systems cannot be understated. This proposed testing will include performance testing, extended operation to establish an extensive reliability database, and characterization testing to quantify subsystem and system performance and better understand system interfaces. This paper details this proposed test program for Stirling radioisotope generator hardware at NASA GRC. It explains the rationale behind the proposed tests and how these tests will meet the stated objectives.

  15. The calibration and flight test performance of the space shuttle orbiter air data system

    NASA Technical Reports Server (NTRS)

    Dean, A. S.; Mena, A. L.

    1983-01-01

    The Space Shuttle air data system (ADS) is used by the guidance, navigation and control system (GN&C) to guide the vehicle to a safe landing. In addition, postflight aerodynamic analysis requires a precise knowledge of flight conditions. Since the orbiter is essentially an unpowered vehicle, the conventional methods of obtaining the ADS calibration were not available; therefore, the calibration was derived using a unique and extensive wind tunnel test program. This test program included subsonic tests with a 0.36-scale orbiter model, transonic and supersonic tests with a smaller 0.2-scale model, and numerous ADS probe-alone tests. The wind tunnel calibration was further refined with subsonic results from the approach and landing test (ALT) program, thus producing the ADS calibration for the orbital flight test (OFT) program. The calibration of the Space Shuttle ADS and its performance during flight are discussed in this paper. A brief description of the system is followed by a discussion of the calibration methodology, and then by a review of the wind tunnel and flight test programs. Finally, the flight results are presented, including an evaluation of the system performance for on-board systems use and a description of the calibration refinements developed to provide the best possible air data for postflight analysis work.

  16. Lifetime Alcoholics Anonymous Attendance as a Predictor of Spiritual Gains in the Relapse Replication and Extension Project (RREP)

    PubMed Central

    Tonigan, J. Scott; McCallion, Elizabeth A.; Frohe, Tessa; Pearson, Matthew R.

    2016-01-01

    This study investigated the association between extent of lifetime attendance in Alcoholics Anonymous (AA) and spiritual gains among treatment seeking adults for alcohol use disorder (AUD). Participants included 246 individuals from two of the three sites in the Relapse Replication and Extension Project (Lowman, Allen, Stout, 1996). Baseline characteristics included 63% male, 39.9% single, and the average age was 34 years (SD=8.2). The Alcoholics Anonymous Involvement questionnaire (AAI; Tonigan, Connors, & Miller, 1996) was used to assess lifetime AA attendance. The Religious Beliefs & Behaviors Questionnaire (Connors, Tonigan, & Miller, 1996b) was used to assess spirituality. Percent days abstinent (PDA) and drinks per drinking day (DPDD) were measured using the Form 90. At baseline, adults with more extensive AA histories were more severely alcohol impaired although they were no older relative to adults with less past AA exposure. Clear patterns of AA engagement were found between the high-low AA history groups over follow-up, with adults with less AA experience reporting less AA participation across a swath of AA-specific measures. Gains in spiritual practices significantly mediated AA-related benefit as measured by PDA and DPDD. Tests for moderated-mediation indicated that the magnitude of the mediational effect of spiritual gains did not differ between high-low AA history groups. Having an extensive AA history did not advantage (or disadvantage) adults in mobilizing future spiritual practices that are prescribed in AA. Clinical assessment of client AA history is important, however, because it predicts both the nature and extent that clients may participate in AA. PMID:28080094

  17. Data-Mining-Based Intelligent Differential Relaying for Transmission Lines Including UPFC and Wind Farms.

    PubMed

    Jena, Manas Kumar; Samantaray, Subhransu Ranjan

    2016-01-01

    This paper presents a data-mining-based intelligent differential relaying scheme for transmission lines, including flexible ac transmission system device, such as unified power flow controller (UPFC) and wind farms. Initially, the current and voltage signals are processed through extended Kalman filter phasor measurement unit for phasor estimation, and 21 potential features are computed at both ends of the line. Once the features are extracted at both ends, the corresponding differential features are derived. These differential features are fed to a data-mining model known as decision tree (DT) to provide the final relaying decision. The proposed technique has been extensively tested for single-circuit transmission line, including UPFC and wind farms with in-feed, double-circuit line with UPFC on one line and wind farm as one of the substations with wide variations in operating parameters. The test results obtained from simulation as well as in real-time digital simulator testing indicate that the DT-based intelligent differential relaying scheme is highly reliable and accurate with a response time of 2.25 cycles from the fault inception.

  18. A summary of laboratory testing performed to characterize and select an elastomeric O-ring material to be used in the redesigned solid rocket motors of the space transportation system

    NASA Technical Reports Server (NTRS)

    Turner, J. E.

    1993-01-01

    An elastomeric O-ring material is used in the joints of the redesigned solid motors (RSRM's) of the National Space Transportation System (NSTS). The selection of the O-ring material used in the RSRM's was a very thorough process that included efforts by NASA's Marshall Space Flight Center and the Langley Research Center, and the Thiokol Corporation. One of the efforts performed at MSFC was an extensive in-house laboratory test regime to screen potential O-ring materials and ultimately to characterize the elastomeric material that was chosen to be used in the RSRM's. The laboratory tests performed at MSFC are summarized.

  19. Vector wind profile gust model

    NASA Technical Reports Server (NTRS)

    Adelfang, S. I.

    1981-01-01

    To enable development of a vector wind gust model suitable for orbital flight test operations and trade studies, hypotheses concerning the distributions of gust component variables were verified. Methods for verification of hypotheses that observed gust variables, including gust component magnitude, gust length, u range, and L range, are gamma distributed and presented. Observed gust modulus has been drawn from a bivariate gamma distribution that can be approximated with a Weibull distribution. Zonal and meridional gust components are bivariate gamma distributed. An analytical method for testing for bivariate gamma distributed variables is presented. Two distributions for gust modulus are described and the results of extensive hypothesis testing of one of the distributions are presented. The validity of the gamma distribution for representation of gust component variables is established.

  20. Addendum to the User Manual for NASGRO Elastic-Plastic Fracture Mechanics Software Module

    NASA Technical Reports Server (NTRS)

    Gregg, M. Wayne (Technical Monitor); Chell, Graham; Gardner, Brian

    2003-01-01

    The elastic-plastic fracture mechanics modules in NASGRO have been enhanced by the addition of of the following: new J-integral solutions based on the reference stress method and finite element solutions; the extension of the critical crack and critical load modules for cracks with two degrees of freedom that tear and failure by ductile instability; the addition of a proof test analysis module that includes safe life analysis, calculates proof loads, and determines the flaw screening 1 capability for a given proof load; the addition of a tear-fatigue module for ductile materials that simultaneously tear and extend by fatigue; and a multiple cycle proof test module for estimating service reliability following a proof test.

  1. Report on International Collaboration Involving the FE Heater and HG-A Tests at Mont Terri

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Houseworth, Jim; Rutqvist, Jonny; Asahina, Daisuke

    Nuclear waste programs outside of the US have focused on different host rock types for geological disposal of high-level radioactive waste. Several countries, including France, Switzerland, Belgium, and Japan are exploring the possibility of waste disposal in shale and other clay-rich rock that fall within the general classification of argillaceous rock. This rock type is also of interest for the US program because the US has extensive sedimentary basins containing large deposits of argillaceous rock. LBNL, as part of the DOE-NE Used Fuel Disposition Campaign, is collaborating on some of the underground research laboratory (URL) activities at the Mont Terrimore » URL near Saint-Ursanne, Switzerland. The Mont Terri project, which began in 1995, has developed a URL at a depth of about 300 m in a stiff clay formation called the Opalinus Clay. Our current collaboration efforts include two test modeling activities for the FE heater test and the HG-A leak-off test. This report documents results concerning our current modeling of these field tests. The overall objectives of these activities include an improved understanding of and advanced relevant modeling capabilities for EDZ evolution in clay repositories and the associated coupled processes, and to develop a technical basis for the maximum allowable temperature for a clay repository.« less

  2. Trunk Muscle Attributes are Associated with Balance and Mobility in Older Adults: A Pilot Study

    PubMed Central

    Suri, Pradeep; Kiely, Dan K.; Leveille, Suzanne G.; Frontera, Walter R.; Bean, Jonathan. F.

    2010-01-01

    Objective To determine if trunk muscle attributes are associated with balance and mobility performance among mobility-limited older adults. Design Cross-sectional analysis of data from a randomized clinical trial. Setting Outpatient rehabilitation research center. Participants Community-dwelling older adults (N=70; mean age 75.9 y) with mobility limitations as defined by the Short Physical Performance Battery (SPPB). Methods Independent variables included physiologic measures of trunk extension strength, trunk flexion strength, trunk extension endurance, trunk extension endurance and leg press strength. All measures were well tolerated by the study subjects without the occurrence of any associated injuries or adverse events. The association of each physiologic measure with each outcome was examined, using separate multivariate models to calculate the partial variance (R2) of each trunk and extremity measure. Main Outcome Measurements Balance measured by the Berg Balance Scale (BBS) and Unipedal Stance Test (UST), and mobility performance as measured by the SPPB. Results Trunk extension endurance (partial R2=.14, p=.02), and leg press strength (partial R2=.14, p=.003) accounted for the greatest amount of the variance in SPPB performance. Trunk extension endurance (partial R2=.17, p=.007), accounted for the greatest amount of the variance in BBS performance. Trunk extension strength (R2=.09, p=.03), accounted for the greatest amount of the variance in UST performance. The variance explained by trunk extension endurance equaled or exceeded the variance explained by limb strength across all three performance outcomes. Conclusions Trunk endurance and strength can be safely measured in mobility-limited older adults, and are associated with both balance and mobility performance. Trunk endurance and trunk strength are physiologic attributes worthy of targeting in the rehabilitative care of mobility-limited older adults. PMID:19854420

  3. Increased trunk extension endurance is associated with meaningful improvement in balance among older adults with mobility problems.

    PubMed

    Suri, Pradeep; Kiely, Dan K; Leveille, Suzanne G; Frontera, Walter R; Bean, Jonathan F

    2011-07-01

    To determine whether trunk extension endurance changes with training are associated with clinically meaningful improvements in balance among mobility-limited older adults. Longitudinal data from a randomized controlled trial. Outpatient rehabilitation research center. Community-dwelling older adults (N=64; mean age, 75.9y) with mobility limitations as defined by a score of 4 to 10 on the Short Physical Performance Battery. Sixteen weeks of progressive resistance training. Outcomes were the Berg Balance Scale (BBS) and the Unipedal Stance Time (UST). Predictors included leg strength, leg power, trunk extension endurance, and the product of heart rate and blood pressure (RPP) at the final stage of an exercise tolerance test. We performed an analysis of data from participants who completed 16 weeks of training by using binary outcomes defined by a clinically meaningful change (CMC) from baseline to completion of the intervention (BBS=4 units; UST=5s). The association of predictor variables with balance outcomes was examined separately and together in multivariate adjusted logistic regression models. Trunk extension endurance in seconds (1.04 [1.00-1.09]) was independently associated with CMC on the BBS. Trunk extension endurance (1.02 [1.00-1.03]) was independently associated with CMC on the UST. Other physical attributes were not associated with meaningful change in balance. Improvements in trunk extension endurance were independently associated with CMCs in balance in older adults. Leg strength, leg power, and RPP were not associated with CMC in balance. Poor trunk extension endurance may be a rehabilitative impairment worthy of further study as a modifiable factor linked to balance among older adults. Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. Trunk muscle attributes are associated with balance and mobility in older adults: a pilot study.

    PubMed

    Suri, Pradeep; Kiely, Dan K; Leveille, Suzanne G; Frontera, Walter R; Bean, Jonathan F

    2009-10-01

    To determine whether trunk muscle attributes are associated with balance and mobility performance among mobility-limited older adults. Cross-sectional analysis of data from a randomized clinical trial. Outpatient rehabilitation research center. Community-dwelling older adults (N = 70; mean age 75.9 years) with mobility limitations as defined by the Short Physical Performance Battery (SPPB). Independent variables included physiologic measures of trunk extension strength, trunk flexion strength, trunk extension endurance, trunk extension endurance, and leg press strength. All measures were well tolerated by the study subjects without the occurrence of any associated injuries or adverse events. The association of each physiologic measure with each outcome was examined by the use of separate multivariate models to calculate the partial variance (R(2)) of each trunk and extremity measure. Balance measured by the Berg Balance Scale and Unipedal Stance Test and mobility performance as measured by the SPPB. Trunk extension endurance (partial R(2) = .14, P = .02), and leg press strength (partial R(2) = .14, P = .003) accounted for the greatest amount of the variance in SPPB performance. Trunk extension endurance (partial R(2) = .17, P = .007), accounted for the greatest amount of the variance in BBS performance. Trunk extension strength (R(2) = .09, P = .03), accounted for the greatest amount of the variance in UST performance. The variance explained by trunk extension endurance equaled or exceeded the variance explained by limb strength across all three performance outcomes. Trunk endurance and strength can be safely measured in mobility-limited older adults and are associated with both balance and mobility performance. Trunk endurance and trunk strength are physiologic attributes worthy of targeting in the rehabilitative care of mobility-limited older adults.

  5. Advanced Stirling Convertor Durability Testing: Plans and Interim Results

    NASA Technical Reports Server (NTRS)

    Meer, David W.; Oriti, Salvatore M.

    2012-01-01

    The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. In support of this program, GRC has been involved in testing Stirling convertors, including the Advanced Stirling Convertor (ASC), for use in the ASRG. This testing includes electromagnetic interference/compatibility (EMI/EMC), structural dynamics, advanced materials, organics, and unattended extended operation. The purpose of the durability tests is to experimentally demonstrate the margins in the ASC design. Due to the high value of the hardware, previous ASC tests focused on establishing baseline performance of the convertors within the nominal operating conditions. The durability tests present the first planned extension of the operating conditions into regions beyond those intended to meet the product spec, where the possibility exists of lateral contact, overstroke, or over-temperature events. These tests are not intended to cause damage that would shorten the life of the convertors, so they can transition into extended operation at the conclusion of the tests. This paper describes the four tests included in the durability test sequence: 1) start/stop cycling, 2) exposure to constant acceleration in the lateral and axial directions, 3) random vibration at increased piston amplitude to induce contact events, and 4) overstroke testing to simulate potential failures during processing or during the mission life where contact events could occur. The paper also summarizes the analysis and simulation used to predict the results of each of these tests.

  6. Load Testing of GFRP Composite U-Shape Footbridge

    NASA Astrophysics Data System (ADS)

    Pyrzowski, Łukasz; Miśkiewicz, Mikołaj; Chróścielewski, Jacek; Wilde, Krzysztof

    2017-10-01

    The paper presents the scope of load tests carried out on an innovative shell composite footbridge. The tested footbridge was manufactured in one production cycle and has no components made from materials other than GFRP laminates and PET foam. The load tests, performed on a 14-m long structure, were the final stage of a research program in the Fobridge project carried out in cooperation with: Gdańsk University of Technology (leader), Military University of Technology in Warsaw, and ROMA Co. Ltd.; and co-financed by NCBR. The aim of the tests was to confirm whether the complex U-shape sandwich structure behaves correctly. The design and technological processes involved in constructing this innovative footbridge required the solving of many problems: absence of standards for design of composite footbridges, lack of standardized material data, lack of guidelines for calculation and evaluation of material strength, and no guidelines for infusion of large, thick sandwich elements. Obtaining answers during the design process demanded extensive experimental tests, development of material models, validation of models, updating parameters and extensive numerical parametric studies. The technological aspects of infusion were tested in numerous trials involving the selection of material parameters and control of the infusion parameters. All scientific validation tests were successfully completed and market assessment showed that the proposed product has potential applications; it can be used for overcoming obstacles in rural areas and cities, as well as in regions affected by natural disasters. Load testing included static and dynamic tests. During the former, the span was examined at 117 independent measurement points. The footbridge was loaded with concrete slabs in different configurations. Their total weight ranged from 140 kN up to 202 kN. The applied load at the most heavily loaded structural points caused an effect from 89% to 120%, compared to the load specified by standards (5 kN/m2). Dynamic tests included standard actions (walking, running, synchronous jumps) as well as aggressive tests, all designed to confirm the usability of the footbridge. The performed trials allowed the identification of the modal and damping parameters of the structure. The designated first natural frequency with a value of 7.8 Hz confirmed the correctness of the U-shape cross-section design due to its significant structural rigidity.

  7. Lorentz-symmetry test at Planck-scale suppression with nucleons in a spin-polarized 133Cs cold atom clock

    NASA Astrophysics Data System (ADS)

    Pihan-Le Bars, H.; Guerlin, C.; Lasseri, R.-D.; Ebran, J.-P.; Bailey, Q. G.; Bize, S.; Khan, E.; Wolf, P.

    2017-04-01

    We introduce an improved model that links the frequency shift of the 133Cs hyperfine Zeeman transitions |F =3 ,mF ⟩↔|F =4 ,mF ⟩ to the Lorentz-violating Standard Model extension (SME) coefficients of the proton and neutron. The new model uses Lorentz transformations developed to second order in boost and additionally takes the nuclear structure into account, beyond the simple Schmidt model used previously in Standard Model extension analyses, thereby providing access to both proton and neutron SME coefficients including the isotropic coefficient c˜T T. Using this new model in a second analysis of the data delivered by the FO2 dual Cs/Rb fountain at Paris Observatory and previously analyzed in [1], we improve by up to 13 orders of magnitude the present maximum sensitivities for laboratory tests [2] on the c˜Q, c˜T J, and c˜T T coefficients for the neutron and on the c˜Q coefficient for the proton, reaching respectively 10-20, 10-17, 10-13, and 10-15 GeV .

  8. Extensions of D-optimal Minimal Designs for Symmetric Mixture Models

    PubMed Central

    Raghavarao, Damaraju; Chervoneva, Inna

    2017-01-01

    The purpose of mixture experiments is to explore the optimum blends of mixture components, which will provide desirable response characteristics in finished products. D-optimal minimal designs have been considered for a variety of mixture models, including Scheffé's linear, quadratic, and cubic models. Usually, these D-optimal designs are minimally supported since they have just as many design points as the number of parameters. Thus, they lack the degrees of freedom to perform the Lack of Fit tests. Also, the majority of the design points in D-optimal minimal designs are on the boundary: vertices, edges, or faces of the design simplex. In This Paper, Extensions Of The D-Optimal Minimal Designs Are Developed For A General Mixture Model To Allow Additional Interior Points In The Design Space To Enable Prediction Of The Entire Response Surface Also a new strategy for adding multiple interior points for symmetric mixture models is proposed. We compare the proposed designs with Cornell (1986) two ten-point designs for the Lack of Fit test by simulations. PMID:29081574

  9. Clinical update on contact allergy.

    PubMed

    Uter, Wolfgang; Johansen, Jeanne Duus; Orton, David I; Frosch, Peter J; Schnuch, Axel

    2005-10-01

    The aim of this article is to review recent findings in contact allergy, regarding clinical research. The biocide methyldibromo glutaronitrile was identified to be an important sensitizer. Subsequently, it was banned from leave-on cosmetics in the European Union. Another group of important allergens that have been studied extensively included the fragrances oak moss absolute, isoeugenol, hydroxyisohexyl 3-cyclohexene carboxaldehyde and farnesol. A new fragrance mix II has been developed for standard testing, which includes the two latter compounds. Dose response studies have demonstrated broad individual variation of elicitation thresholds, dependent on the allergen concentration during induction, and other factors. Some unsuspected routes of exposure to allergens include oral, inhalational, connubial or airborne contact. Experimental studies provide a classification of newly introduced chemicals; increasingly, the local lymph node assay is supplementing and potentially replacing the guinea pig maximization test. Recent advances in occupational contact allergy include, for example, some attempts to improve diagnostics for epoxy resin and other plastic, glue, and cutting fluid components. Constant awareness for new allergens, confirmed by critical evaluation, standardization of patch test materials, and the identification of temporal patterns and subgroups at risk will improve both the diagnosis and prevention of allergic contact dermatitis.

  10. Performance documentation of the engineering model 30-cm diameter thruster

    NASA Technical Reports Server (NTRS)

    Bechtel, R. T.; Rawlin, V. K.

    1976-01-01

    The results of extensive testing of two 30-cm ion thrusters which are virtually identical to the 900 series Engineering Model Thruster in an ongoing 15,000-hour life test are presented. Performance data for the nominal fullpower (2650 W) operating point; performance sensitivities to discharge voltage, discharge losses, accelerator voltage, and magnetic baffle current; and several power throttling techniques (maximum Isp, maximum thrust/power ratio, and two cases in between are included). Criteria for throttling are specified in terms of the screen power supply envelope, thruster operating limits, and control stability. In addition, reduced requirements for successful high voltage recycles are presented.

  11. Development of the improved helicopter icing spray system (IHISS)

    NASA Technical Reports Server (NTRS)

    Peterson, Andrew A.; Jenks, Mark D.; Gaitskill, William H.

    1989-01-01

    Boeing Helicopters has been awarded a contract by the U.S. Army to design, fabricate and test a replacement for the existing Helicopter Icing Spray System (HISS). The Improved Hiss (IHISS), capable of deployment from any CH-47D helicopter, will include new icing spray nozzles and pneumatic pressure source, and a significantly larger water tank and spray boom. Results are presented for extensive bench and icing tunnel test programs used to select and modify an improved spray nozzle and validate spray boom aerodynamic characteristics. The resulting system will provide a significantly larger icing cloud with droplet characteristics closely matching natural icing conditions.

  12. Extension of Ostwald Ripening Theory

    NASA Technical Reports Server (NTRS)

    Baird, J.; Naumann, R.

    1985-01-01

    The objective is to develop models based on the mean field approximation of Ostwald ripening to describe the growth of second phase droplets or crystallites. The models will include time variations in nucleation rate, control of saturation through addition of solute, precipitating agents, changes in temperature, and various surface kinetic effects. Numerical integration schemes have been developed and tested against the asymptotic solution of Liftshitz, Slyozov and Wagner (LSW). A second attractor (in addition to the LSW distribution) has been found and, contrary to the LSW theory, the final distribution is dependent on the initial distribution. A series of microgravity experiments is being planned to test this and other results from this work.

  13. Extension of moment projection method to the fragmentation process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Shaohua; Yapp, Edward K.Y.; Akroyd, Jethro

    2017-04-15

    The method of moments is a simple but efficient method of solving the population balance equation which describes particle dynamics. Recently, the moment projection method (MPM) was proposed and validated for particle inception, coagulation, growth and, more importantly, shrinkage; here the method is extended to include the fragmentation process. The performance of MPM is tested for 13 different test cases for different fragmentation kernels, fragment distribution functions and initial conditions. Comparisons are made with the quadrature method of moments (QMOM), hybrid method of moments (HMOM) and a high-precision stochastic solution calculated using the established direct simulation algorithm (DSA) and advantagesmore » of MPM are drawn.« less

  14. Investigations of Air-cooled Turbine Rotors for Turbojet Engines II : Mechanical Design, Stress Analysis, and Burst Test of Modified J33 Split-disk Rotor / Richard H. Kemp and Merland L. Moseson

    NASA Technical Reports Server (NTRS)

    Kemp, Richard H; Moseson, Merland L

    1952-01-01

    A full-scale J33 air-cooled split turbine rotor was designed and spin-pit tested to destruction. Stress analysis and spin-pit results indicated that the rotor in a J33 turbojet engine, however, showed that the rear disk of the rotor operated at temperatures substantially higher than the forward disk. An extension of the stress analysis to include the temperature difference between the two disks indicated that engine modifications are required to permit operation of the two disks at more nearly the same temperature level.

  15. Evapotranspiration from nonuniform surfaces - A first approach for short-term numerical weather prediction

    NASA Technical Reports Server (NTRS)

    Wetzel, Peter J.; Chang, Jy-Tai

    1988-01-01

    Observations of surface heterogeneity of soil moisture from scales of meters to hundreds of kilometers are discussed, and a relationship between grid element size and soil moisture variability is presented. An evapotranspiration model is presented which accounts for the variability of soil moisture, standing surface water, and vegetation internal and stomatal resistance to moisture flow from the soil. The mean values and standard deviations of these parameters are required as input to the model. Tests of this model against field observations are reported, and extensive sensitivity tests are presented which explore the importance of including subgrid-scale variability in an evapotranspiration model.

  16. Test-retest reliability of cardinal plane isokinetic hip torque and EMG.

    PubMed

    Claiborne, Tina L; Timmons, Mark K; Pincivero, Danny M

    2009-10-01

    The objective of the present study was to establish test-retest reliability of isokinetic hip torque and prime mover electromyogram (EMG) through the three cardinal planes of motion. Thirteen healthy young adults participated in two experimental sessions, separated by approximately one week. During each session, isokinetic hip torque was evaluated on the Biodex Isokinetic Dynamometer at a velocity of 60 deg/s. Subjects performed three maximal-effort concentric and eccentric contractions, separately, for right and left hip abduction/adduction, flexion/extension, and internal/external rotation. Surface EMGs were sampled from the gluteus maximus, gluteus medius, adductor, medial and lateral hamstring, and rectus femoris muscles during all contractions. Intraclass correlation coefficients (ICC - 2,1) and standard errors of measurement (SEM) were calculated for peak torque for each movement direction and contraction mode, while ICCs were only computed for the EMG data. Motions that demonstrated high torque reliability included concentric hip abduction (right and left), flexion (right and left), extension (right) and internal rotation (right and left), and eccentric hip abduction (left), adduction (left), flexion (right), and extension (right and left) (ICC range=0.81-0.91). Motions with moderate torque reliability included concentric hip adduction (right), extension (left), internal rotation (left), and external rotation (right), and eccentric hip abduction and adduction (right), flexion (left), internal rotation (right and left), and external rotation (right and left) (ICC range=0.49-0.79). The majority of the EMG sampled muscles (n=12 and n=11 for concentric and eccentric contractions, respectively) demonstrated high reliability (ICC=0.81-0.95). Instances of low, or unacceptable, EMG reliability values occurred for the medial hamstring muscle of the left leg (both contraction modes) and the adductor muscle of the right leg during eccentric internal rotation. The major finding revealed high and moderate levels of between-day reliability of isokinetic hip peak torque and prime mover EMG. It is recommended that the day-to-day variability estimates concomitant with acceptable levels of reliability be considered when attempting to objectify intervention effects on hip muscle performance.

  17. The Computational Infrastructure for Geodynamics as a Community of Practice

    NASA Astrophysics Data System (ADS)

    Hwang, L.; Kellogg, L. H.

    2016-12-01

    Computational Infrastructure for Geodynamics (CIG), geodynamics.org, originated in 2005 out of community recognition that the efforts of individual or small groups of researchers to develop scientifically-sound software is impossible to sustain, duplicates effort, and makes it difficult for scientists to adopt state-of-the art computational methods that promote new discovery. As a community of practice, participants in CIG share an interest in computational modeling in geodynamics and work together on open source software to build the capacity to support complex, extensible, scalable, interoperable, reliable, and reusable software in an effort to increase the return on investment in scientific software development and increase the quality of the resulting software. The group interacts regularly to learn from each other and better their practices formally through webinar series, workshops, and tutorials and informally through listservs and hackathons. Over the past decade, we have learned that successful scientific software development requires at a minimum: collaboration between domain-expert researchers, software developers and computational scientists; clearly identified and committed lead developer(s); well-defined scientific and computational goals that are regularly evaluated and updated; well-defined benchmarks and testing throughout development; attention throughout development to usability and extensibility; understanding and evaluation of the complexity of dependent libraries; and managed user expectations through education, training, and support. CIG's code donation standards provide the basis for recently formalized best practices in software development (geodynamics.org/cig/dev/best-practices/). Best practices include use of version control; widely used, open source software libraries; extensive test suites; portable configuration and build systems; extensive documentation internal and external to the code; and structured, human readable input formats.

  18. Stochastic model of cell rearrangements in convergent extension of ascidian notochord

    NASA Astrophysics Data System (ADS)

    Lubkin, Sharon; Backes, Tracy; Latterman, Russell; Small, Stephen

    2007-03-01

    We present a discrete stochastic cell based model of convergent extension of the ascidian notochord. Our work derives from research that clarifies the coupling of invagination and convergent extension in ascidian notochord morphogenesis (Odell and Munro, 2002). We have tested the roles of cell-cell adhesion, cell-extracellular matrix adhesion, random motion, and extension of individual cells, as well as the presence or absence of various tissue types, and determined which factors are necessary and/or sufficient for convergent extension.

  19. Testing a New Generation: Implementing Clickers as an Extension Data Collection Tool

    ERIC Educational Resources Information Center

    Parmer, Sondra M.; Parmer, Greg; Struempler, Barb

    2012-01-01

    Using clickers to gauge student understanding in large classrooms is well documented. Less well known is the effectiveness of using clickers with youth for test taking in large-scale Extension programs. This article describes the benefits and challenges of collecting evaluation data using clickers with a third-grade population participating in a…

  20. 76 FR 24034 - Determination of Regulatory Review Period for Purposes of Patent Extension; CONVENIA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-29

    ... periods of time: A testing phase and an approval phase. For animal drug products, the testing phase begins... and Trademarks, Department of Commerce, for the extension of a patent which claims that animal drug... Animal Drug and Patent Term Restoration Act (Pub. L. 100-670) generally provide that a patent may be...

  1. A Meta-Analysis of Extensive Reading Research

    ERIC Educational Resources Information Center

    Nakanishi, Takayuki

    2015-01-01

    The purposes of this study were to investigate the overall effectiveness of extensive reading, whether learners' age impacts learning, and whether the length of time second language learners engage in extensive reading influences test scores. The author conducted a meta-analysis to answer research questions and to identify future research…

  2. Laboratory diagnosis of Ebola virus disease and corresponding biosafety considerations in the China Ebola Treatment Center.

    PubMed

    Huang, Qing; Fu, Wei-Ling; You, Jian-Ping; Mao, Qing

    2016-10-01

    Ebola virus disease (EVD), caused by Ebola virus (EBOV), is a potent acute infectious disease with a high case-fatality rate. Etiological and serological EBOV detection methods, including techniques that involve the detection of the viral genome, virus-specific antigens and anti-virus antibodies, are standard laboratory diagnostic tests that facilitate confirmation or exclusion of EBOV infection. In addition, routine blood tests, liver and kidney function tests, electrolytes and coagulation tests and other diagnostic examinations are important for the clinical diagnosis and treatment of EVD. Because of the viral load in body fluids and secretions from EVD patients, all body fluids are highly contagious. As a result, biosafety control measures during the collection, transport and testing of clinical specimens obtained from individuals scheduled to undergo EBOV infection testing (including suspected, probable and confirmed cases) are crucial. This report has been generated following extensive work experience in the China Ebola Treatment Center (ETC) in Liberia and incorporates important information pertaining to relevant diagnostic standards, clinical significance, operational procedures, safety controls and other issues related to laboratory testing of EVD. Relevant opinions and suggestions are presented in this report to provide contextual awareness associated with the development of standards and/or guidelines related to EVD laboratory testing.

  3. Solar thermal vacuum tests of Magellan spacecraft

    NASA Technical Reports Server (NTRS)

    Neuman, James C.

    1990-01-01

    The Magellen solar/thermal/vacuum test involved a number of unique requirements and approaches. Because of the need to operate in orbit around Venus, the solar intensity requirement ranged up to 2.3 suns or Earth equivalent solar constants. Extensive modification to the solar simulator portion of the test facility were required to achieve this solar intensity. Venus albedo and infrared emission were simulated using temperature controlled movable louver panels to allow the spacecraft to view either a selectable temperature black heat source with closed louvers, or the chamber coldwall behind open louvers. The test conditions included widely varying solar intensities, multiple sun angles, alternate hardware configurations, steady state and transient cases, and cruise and orbital power profiles. Margin testing was also performed, wherein supplemental heaters were mounted to internal thermal blankets to verify spacecraft performance at higher than expected temperatures. The test was successful, uncovering some spacecraft anomalies and verifying the thermal design. The test support equipment experienced some anomalous behavior and a significant failure during the test.

  4. Propfan test assessment propfan propulsion system static test report

    NASA Technical Reports Server (NTRS)

    Orourke, D. M.

    1987-01-01

    The propfan test assessment (PTA) propulsion system successfully completed over 50 hours of extensive static ground tests, including a 36 hour endurance test. All major systems performed as expected, verifying that the large-scale 2.74 m diameter propfan, engine, gearbox, controls, subsystems, and flight instrumentation will be satisfactory with minor modifications for the upcoming PTA flight tests on the GII aircraft in early 1987. A test envelope was established for static ground operation to maintain propfan blade stresses within limits for propfan rotational speeds up to 105 percent and power levels up to 3880 kW. Transient tests verified stable, predictable response of engine power and propfan speed controls. Installed engine TSFC was better than expected, probably due to the excellent inlet performance coupled with the supercharging effect of the propfan. Near- and far-field noise spectra contained three dominant components, which were dependent on power, tip speed, and direction. The components were propfan blade tones, propfan random noise, and compressor/propfan interaction noise. No significant turbine noise or combustion noise was evident.

  5. David Florida Laboratory: Support for mobile satellite communications

    NASA Technical Reports Server (NTRS)

    Dumoulin, Jean-Guy; Mamen, Rolf

    1995-01-01

    The comprehensive integration and environmental (including RF) test facilities of the Canadian Space Agency's David Florida Laboratory (CSA)(DFL) were used extensively for the MSAT Program. Following a description of the facilities, the paper outlines their application to the qualification of the two MSAT satellites following an overview of the test plan. Particular emphasis is given to passive intermodulation measurement (PIM) demands, which for the MSAT satellites, contributed to the need to extend the anechoic chamber. The extended chamber was also used for an EMC test and SAR signature test of the RADARSAT satellite. The DFL's facilities are being used for additional aspects of mobile satellite communications. One shielded anechoic Extra High Frequency (EHF) chamber and associated test equipment are employed predominantly for measuring the performance of the IRIDIUM satellites' Engineering Model Gateway Moveable Antennas (EM)(GMA). Other chambers are used for testing aeronautical antennas on behalf of Inmarsat. Still others combine thermal and PIM testing. The paper concludes with a review of the test requirements of evolving satcom missions such as Inmarsat Aero-1.

  6. Needle puncture in rabbit functional spinal units alters rotational biomechanics.

    PubMed

    Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D

    2015-04-01

    An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were <3% and 1%, respectively, of moment-rotation target values. Flexibility moment targets were 0.3 N m for flexion and axial rotation and 0.15 N m for extension and lateral bending. Needle puncture caused significant (P<0.05) changes only in flexion/extension range-of-motion and neutral zone stiffness and width (N m) compared with preintervention. No. 11 blade-stab significantly increased range-of-motion in all motions, decreased neutral zone stiffness and width (N m) in flexion/extension, and increased elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.

  7. Materials screening chamber for testing materials resistance to atomic oxygen

    NASA Technical Reports Server (NTRS)

    Pippin, H. G.; Carruth, Ralph

    1989-01-01

    A unique test chamber for exposing material to a known flux of oxygen atoms is described. The capabilities and operating parameters of the apparatus include production of an oxygen atom flux in excess of 5 x 10 to the 16th atoms/sq cm-sec, controlled heating of the sample specimen, RF circuitry to contain the plasma within a small volume, and long exposure times. Flux measurement capabilities include a calorimetric probe and a light titration system. Accuracy and limitations of these techniques are discussed. An extension to the main chamber to allow simultaneous ultraviolet and atomic oxygen exposure is discussed. The oxygen atoms produced are at thermal energies. Sample specimens are maintained at any selected temperature between ambient and 200 C, to within + or - 2 C. A representative example of measurements made using the chamber is presented.

  8. Semiquantitative determination of mesophilic, aerobic microorganisms in cocoa products using the Soleris NF-TVC method.

    PubMed

    Montei, Carolyn; McDougal, Susan; Mozola, Mark; Rice, Jennifer

    2014-01-01

    The Soleris Non-fermenting Total Viable Count method was previously validated for a wide variety of food products, including cocoa powder. A matrix extension study was conducted to validate the method for use with cocoa butter and cocoa liquor. Test samples included naturally contaminated cocoa liquor and cocoa butter inoculated with natural microbial flora derived from cocoa liquor. A probability of detection statistical model was used to compare Soleris results at multiple test thresholds (dilutions) with aerobic plate counts determined using the AOAC Official Method 966.23 dilution plating method. Results of the two methods were not statistically different at any dilution level in any of the three trials conducted. The Soleris method offers the advantage of results within 24 h, compared to the 48 h required by standard dilution plating methods.

  9. The virtual morphology and the main movements of the human neck simulations used for car crash studies

    NASA Astrophysics Data System (ADS)

    Ciunel, St.; Tica, B.

    2016-08-01

    The paper presents the studies made on a similar biomechanical system composed by neck, head and thorax bones. The models were defined in a CAD environment which includes Adams algorithm for dynamic simulations. The virtual models and the entire morphology were obtained starting with CT images made on a living human subject. The main movements analyzed were: axial rotation (left-right), lateral bending (left-right) and flexion- extension movement. After simulation was obtained the entire biomechanical behavior based on data tables or diagrams. That virtual model composed by neck and head can be included in complex system (as a car system) and supposed to several impact simulations (virtual crash tests). Also, our research team built main components of a testing device for dummy car crash neck-head system using anatomical data.

  10. Simulation of ion-temperature-gradient turbulence in tokamaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohen, B I; Dimits, A M; Kim, C

    Results are presented from nonlinear gyrokinetic simulations of toroidal ion temperature gradient (ITG) turbulence and transport. The gyrokinetic simulations are found to yield values of the thermal diffusivity significantly lower than gyrofluid or IFS-PPPL-model predictions. A new phenomenon of nonlinear effective critical gradients larger than the linear instability threshold gradients is observed, and is associated with undamped flux-surface-averaged shear flows. The nonlinear gyrokineic codes have passed extensive validity tests which include comparison against independent linear calculations, a series of nonlinear convergence tests, and a comparison between two independent nonlinear gyrokinetic codes. Our most realistic simulations to date have actual reconstructedmore » equilibria from experiments and a model for dilution by impurity and beam ions. These simulations highlight the need for still more physics to be included in the simulations« less

  11. The Effectiveness of PNF Versus Static Stretching on Increasing Hip-Flexion Range of Motion.

    PubMed

    Lempke, Landon; Wilkinson, Rebecca; Murray, Caitlin; Stanek, Justin

    2018-05-22

    Clinical Scenario: Stretching is applied for the purposes of injury prevention, increasing joint range of motion (ROM), and increasing muscle extensibility. Many researchers have investigated various methods and techniques to determine the most effective way to increase joint ROM and muscle extensibility. Despite the numerous studies conducted, controversy still remains within clinical practice and the literature regarding the best methods and techniques for stretching. Focused Clinical Question: Is proprioceptive neuromuscular facilitation (PNF) stretching more effective than static stretching for increasing hamstring muscle extensibility through increased hip ROM or increased knee extension angle (KEA) in a physically active population? Summary of Key Findings: Five studies met the inclusion criteria and were included. All 5 studies were randomized control trials examining mobility of the hamstring group. The studies measured hamstring ROM in a variety of ways. Three studies measured active KEA, 1 study measured passive KEA, and 1 study measured hip ROM via the single-leg raise test. Of the 5 studies, 1 study found greater improvements using PNF over static stretching for increasing hip flexion, and the remaining 4 studies found no significant difference between PNF stretching and static stretching in increasing muscle extensibility, active KEA, or hip ROM. Clinical Bottom Line: PNF stretching was not demonstrated to be more effective at increasing hamstring extensibility compared to static stretching. The literature reviewed suggests both are effective methods for increasing hip-flexion ROM. Strength of Recommendation: Using level 2 evidence and higher, the results show both static and PNF stretching effectively increase ROM; however, one does not appear to be more effective than the other.

  12. Bias extension test on a bi-axial non-crimp fabric powdered with a non-reactive binder system

    NASA Astrophysics Data System (ADS)

    Pourtier, Jean; Duchamp, Boris; Kowalski, Maxime; Legrand, Xavier; Wang, Peng; Soulat, Damien

    2018-05-01

    In this communication, we investigated the effects of a chemical non-reactive binder system (powder) on the formability of NCF. Those influences are evaluated for two different of bi-axial NCF structures tested in a range of temperature [20°C - 140°] during bias extension tests (Fig. 1). This analyze is based on the study of force in function of deformation modes (slipping effects and shear angle field).

  13. Validity and Reliability of a New Device (WIMU®) for Measuring Hamstring Muscle Extensibility.

    PubMed

    Muyor, José M

    2017-09-01

    The aims of the current study were 1) to evaluate the validity of the WIMU ® system for measuring hamstring muscle extensibility in the passive straight leg raise (PSLR) test using an inclinometer for the criterion and 2) to determine the test-retest reliability of the WIMU ® system to measure hamstring muscle extensibility during the PSLR test. 55 subjects were evaluated on 2 separate occasions. Data from a Unilever inclinometer and WIMU ® system were collected simultaneously. Intraclass correlation coefficients (ICCs) for the validity were very high (0.983-1); a very low systematic bias (-0.21°--0.42°), random error (0.05°-0.04°) and standard error of the estimate (0.43°-0.34°) were observed (left-right leg, respectively) between the 2 devices (inclinometer and the WIMU ® system). The R 2 between the devices was 0.999 (p<0.001) in both the left and right legs. The test-retest reliability of the WIMU ® system was excellent, with ICCs ranging from 0.972-0.995, low coefficients of variation (0.01%), and a low standard error of the estimate (0.19-0.31°). The WIMU ® system showed strong concurrent validity and excellent test-retest reliability for the evaluation of hamstring muscle extensibility in the PSLR test. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Development, validity and reliability of a new pressure air biofeedback device (PAB) for measuring isometric extension strength of the lumbar spine.

    PubMed

    Pienaar, Andries W; Barnard, Justhinus G

    2017-04-01

    This study describes the development of a new portable muscle testing device, using air pressure as a biofeedback and strength testing tool. For this purpose, a pressure air biofeedback device (PAB ® ) was developed to measure and record the isometric extension strength of the lumbar multifidus muscle in asymptomatic and low back pain (LBP) persons. A total of 42 subjects (age 47.58 years, ±18.58) participated in this study. The validity of PAB ® was assessed by comparing a selected measure, air pressure force in millibar (mb), to a standard criterion; calibrated weights in kilograms (kg) during day-to-day tests. Furthermore, clinical trial-to-trial and day-to-day tests of maximum voluntary isometric contraction (MVIC) of L5 lumbar multifidus were done to compare air pressure force (mb) to electromyography (EMG) in microvolt (μV) and to measure the reliability of PAB ® . A highly significant relationship were found between air pressure output (mb) and calibrated weights (kg). In addition, Pearson correlation calculations showed a significant relationship between PAB ® force (mb) and EMG activity (μV) for all subjects (n = 42) examined, as well as for the asymptomatic group (n = 24). No relationship was detected for the LBP group (n = 18). In terms of lumbar extension strength, we found that asymptomatic subjects were significantly stronger than LBP subjects. The results of the PAB ® test differentiated between LBP and asymptomatic subject's lumbar isometric extension strength without any risk to the subjects and also indicate that the lumbar isometric extension test with the new PAB ® device is reliable and valid.

  15. Practical robotic self-awareness and self-knowledge

    NASA Astrophysics Data System (ADS)

    Gage, Douglas W.

    2011-05-01

    The functional software components of an autonomous robotic system express behavior via commands to its actuators, based on processed inputs from its sensors; we propose an additional set of "cognitive" capabilities for robotic systems of all types, based on the comprehensive logging of all available data, including sensor inputs, behavioral states, and outputs sent to actuators. A robot should maintain a "sense" of its own (piecewise) continuous existence through time and space; it should in some sense "get a life," providing a level of self-awareness and self-knowledge. Self-awareness includes the ability to survive and work through unexpected power glitches while executing a task or mission. Selfknowledge includes an extensive world model including a model of self and the purpose context in which it is operating (deontics). Our system must support proactive self-test, monitoring, and calibration, and maintain a "personal" health/repair history, supporting system test and evaluation by continuously measuring performance throughout the entire product lifecycle. It will include episodic memory, and a system "lifelog," and will also participate in multiple modes of Human Robotic interaction (HRI).

  16. Levitating Trains and Kamikaze Genes: Technological Literacy for the Future

    NASA Astrophysics Data System (ADS)

    Brennan, Richard P.

    1994-08-01

    A lively survey of the horizons of modern technology. Provides easy-to-read summaries of the state of the art in space science, biotechnology, computer science, exotic energy sources and materials engineering as well as life-enhancing medical advancements and environmental, transportation and defense/weapons technologies. Each chapter explains how a current or future technology works and provides an understanding of the underlying scientific concepts. Includes an extensive self-test to review your knowledge.

  17. Extension and Validation of a Hybrid Particle-Finite Element Method for Hypervelocity Impact Simulation. Chapter 2

    NASA Technical Reports Server (NTRS)

    Fahrenthold, Eric P.; Shivarama, Ravishankar

    2004-01-01

    The hybrid particle-finite element method of Fahrenthold and Horban, developed for the simulation of hypervelocity impact problems, has been extended to include new formulations of the particle-element kinematics, additional constitutive models, and an improved numerical implementation. The extended formulation has been validated in three dimensional simulations of published impact experiments. The test cases demonstrate good agreement with experiment, good parallel speedup, and numerical convergence of the simulation results.

  18. Prediction of Acute Mountain Sickness Using a Blood Based Test

    DTIC Science & Technology

    2017-01-01

    reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching...develop acute mountain sickness (AMS) when they travel to high altitudes. OVERALL PROJECT SUMMARY: Following program reviews over the last 24 months we...research. That work is ongoing and will continue for remainder of the time we work on this grant. We completed the request for a no cost extension. And we

  19. Extended observability of linear time-invariant systems under recurrent loss of output data

    NASA Technical Reports Server (NTRS)

    Luck, Rogelio; Ray, Asok; Halevi, Yoram

    1989-01-01

    Recurrent loss of sensor data in integrated control systems of an advanced aircraft may occur under different operating conditions that include detected frame errors and queue saturation in computer networks, and bad data suppression in signal processing. This paper presents an extension of the concept of observability based on a set of randomly selected nonconsecutive outputs in finite-dimensional, linear, time-invariant systems. Conditions for testing extended observability have been established.

  20. Summary of Threatened and Endangered Bat-Related Restrictions on Military Training, Testing, and Land Management

    DTIC Science & Technology

    2005-08-01

    include Palmer’s agave ( Agave palmeri), Parry’s agave (A. parryi ), de- sert agave (A. deserti), and amole (A. schotti). Amole is considered to be an...of blooming paniculate agaves (reviewed by Cockrum 1991). Actual dates of these seasonal movements by lesser long-nosed bats are rather variable...roosting colonies require extensive stands of cacti or agave for food (USFWS 1997). Therefore, destruction of food plants many miles from roost

  1. Detection of mild inherited disorders of blood coagulation: current options and personal recommendations.

    PubMed

    Lippi, Giuseppe; Pasalic, Leonardo; Favaloro, Emmanuel J

    2015-08-01

    Although assessment of prior personal and familial bleeding history is an important aspect of the diagnosis of bleeding disorders, patients with mild inherited bleeding disorders are sometimes clinically asymptomatic until presented with a hemostatic challenge. However, bleeding may occur after incursion of trauma or surgery, so detection of these conditions reflects an important facet of clinical and laboratory practice. Mild bleeding disorders may be detected as a result of family studies or following identification of abnormal values in first-line screening tests such as activated partial thromboplastin time, prothrombin time, fibrinogen and global platelet function screen testing, such as the platelet function analyzer. Following determination of abnormal screening tests, subsequent investigation should follow a systematic approach that targets specific diagnostic tests, and including factor assays, full platelet function assays and more extensive specialized hemostasis testing. The current report provides a personal overview on inherited disorders of blood coagulation and their detection.

  2. Thermal testing techniques for space shuttle thermal protection system panels

    NASA Technical Reports Server (NTRS)

    Cox, B. G.

    1972-01-01

    An experimental system was developed for evaluation of the effects of aerodynamic heating and cooling, vacuum, and pressure loading on candidate insulation packages proposed for use on the space shuttle. The system includes a number of design features which facilitate rapid recycle times. This is necessary to efficiently conduct extensive thermal cycling tests on these insulation packages to determine their reuse capabilities. The heart of the system is a 26-inch graphite element radiant heater. A susceptor plate functions as a uniform-temperature intermediate radiating surface. The susceptor also forms the lid of an inert atmosphere enclosure which separates the heater from the oxidizing test atmosphere. In some tests the plate properly simulates the heating from an actual flight heat-shield panel. Although other materials were used at lower required test temperatures, 2500 F was routinely achieved using a coated columbium susceptor plate.

  3. Hockey-stick steam generator for LMFBR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hallinan, G.J.; Svedlund, P.E.

    1981-01-01

    This paper presents the criteria and evaluation leading to the selection of the Hockey Stick Steam Generator Concept and subsequent development of that concept for LMFBR application. The selection process and development of the Modular Steam Generator (MSG) is discussed, including the extensive test programs that culminated in the manufacture and test of a 35 MW(t) Steam Generator. The design of the CRBRP Steam Generator is described, emphasizing the current status and a review of the critical structural areas. CRBRP steam generator development tests are evaluated, with a discussion of test objectives and rating of the usefulness of test resultsmore » to the CRBRP prototype design. Manufacturing experience and status of the CRBRP prototype and plant units is covered. The scaleup of the Hockey Stick concept to large commercial plant application is presented, with an evaluation of scaleup limitations, transient effects, and system design implications.« less

  4. The value of item response theory in clinical assessment: a review.

    PubMed

    Thomas, Michael L

    2011-09-01

    Item response theory (IRT) and related latent variable models represent modern psychometric theory, the successor to classical test theory in psychological assessment. Although IRT has become prevalent in the measurement of ability and achievement, its contributions to clinical domains have been less extensive. Applications of IRT to clinical assessment are reviewed to appraise its current and potential value. Benefits of IRT include comprehensive analyses and reduction of measurement error, creation of computer adaptive tests, meaningful scaling of latent variables, objective calibration and equating, evaluation of test and item bias, greater accuracy in the assessment of change due to therapeutic intervention, and evaluation of model and person fit. The theory may soon reinvent the manner in which tests are selected, developed, and scored. Although challenges remain to the widespread implementation of IRT, its application to clinical assessment holds great promise. Recommendations for research, test development, and clinical practice are provided.

  5. Assessment of Isometric Trunk Strength - The Relevance of Body Position and Relationship between Planes of Movement.

    PubMed

    Kocjan, Andrej; Sarabon, Nejc

    2014-05-01

    The aim of the study was to assess the differences in maximal isometric trunk extension and flexion strength during standing, sitting and kneeling. Additionally, we were interested in correlations between the maximal strength in sagittal, frontal and transverse plane, measured in the sitting position. Sixty healthy subjects (24 male, 36 female; age 41.3 ± 15.1 yrs; body height 1.70 ± 0.09 m; body mass 72.7 ± 13.3 kg) performed maximal voluntary isometric contractions of the trunk flexor and extensor muscles in standing, sitting and kneeling position. The subjects also performed lateral flexions and rotations in the sitting position. Each task was repeated three times and average of maximal forces was used for data analysis. RANOVA with post-hoc testing was applied to the flexion and extension data. The level of statistical significance was set to p < 0.05. Overall, in both genders together, the highest average force for trunk extension was recorded in sitting posture (910.5 ± 271.5 N), followed by kneeling (834.3 ± 242.9 N) and standing (504.0 ± 165.4 N), compared with flexion, where we observed the opposite trend (508.5 ± 213.0 N, 450.9 ± 165.7 N and 443.4 ± 153.1 N, respectively). Post-hoc tests showed significant differences in all extension positions (p < 0.0001) and between sitting/standing (p = 0.018) and kneeling/standing (p = 0.033) flexion exertions. The extension/flexion ratio for sitting was 2.1 ± 0.4, for kneeling 1.9 ± 0.4, followed by standing, where motion forward approximately equals motion backward (1.1 ± 0.6). Trunk sagittal-transverse strength showed the strongest correlation, followed by frontal-transverse and sagittal-frontal plane correlation pairs (R(2) = 0.830, 0.712 and 0.657). The baseline trunk isometric strength data provided by this study should help further strength diagnostics, more precisely, the prevention of low back disorders. Key pointsMaximal voluntary isometric force of the trunk extensors increased with the angle at the hips (highest in sitting, medium in kneeling and lowest in upright standing).The opposite trend was true for isometric MVC force of trunk flexors (both genders together and men only).In the sitting position, the strongest correlation between MVC forces was found between sagittal (average flexion/extension) and transverse plane (average left/right rotation).IN ORDER TO INCREASE THE VALIDITY OF TRUNK STRENGTH TESTING THE LETTER SHOULD INCLUDE: specific warm-up, good pelvic fixation and visual feedback.

  6. Assessment of Isometric Trunk Strength – The Relevance of Body Position and Relationship between Planes of Movement

    PubMed Central

    Kocjan, Andrej; Sarabon, Nejc

    2014-01-01

    The aim of the study was to assess the differences in maximal isometric trunk extension and flexion strength during standing, sitting and kneeling. Additionally, we were interested in correlations between the maximal strength in sagittal, frontal and transverse plane, measured in the sitting position. Sixty healthy subjects (24 male, 36 female; age 41.3 ± 15.1 yrs; body height 1.70 ± 0.09 m; body mass 72.7 ± 13.3 kg) performed maximal voluntary isometric contractions of the trunk flexor and extensor muscles in standing, sitting and kneeling position. The subjects also performed lateral flexions and rotations in the sitting position. Each task was repeated three times and average of maximal forces was used for data analysis. RANOVA with post-hoc testing was applied to the flexion and extension data. The level of statistical significance was set to p < 0.05. Overall, in both genders together, the highest average force for trunk extension was recorded in sitting posture (910.5 ± 271.5 N), followed by kneeling (834.3 ± 242.9 N) and standing (504.0 ± 165.4 N), compared with flexion, where we observed the opposite trend (508.5 ± 213.0 N, 450.9 ± 165.7 N and 443.4 ± 153.1 N, respectively). Post-hoc tests showed significant differences in all extension positions (p < 0.0001) and between sitting/standing (p = 0.018) and kneeling/standing (p = 0.033) flexion exertions. The extension/flexion ratio for sitting was 2.1 ± 0.4, for kneeling 1.9 ± 0.4, followed by standing, where motion forward approximately equals motion backward (1.1 ± 0.6). Trunk sagittal-transverse strength showed the strongest correlation, followed by frontal-transverse and sagittal-frontal plane correlation pairs (R2 = 0.830, 0.712 and 0.657). The baseline trunk isometric strength data provided by this study should help further strength diagnostics, more precisely, the prevention of low back disorders. Key points Maximal voluntary isometric force of the trunk extensors increased with the angle at the hips (highest in sitting, medium in kneeling and lowest in upright standing). The opposite trend was true for isometric MVC force of trunk flexors (both genders together and men only). In the sitting position, the strongest correlation between MVC forces was found between sagittal (average flexion/extension) and transverse plane (average left/right rotation). In order to increase the validity of trunk strength testing the letter should include: specific warm-up, good pelvic fixation and visual feedback. PMID:24790491

  7. Hierarchical Testing with Automated Document Generation for Amanzi, ASCEM's Subsurface Flow and Reactive Transport Simulator

    NASA Astrophysics Data System (ADS)

    Moulton, J. D.; Steefel, C. I.; Yabusaki, S.; Castleton, K.; Scheibe, T. D.; Keating, E. H.; Freedman, V. L.

    2013-12-01

    The Advanced Simulation Capabililty for Environmental Management (ASCEM) program is developing an approach and open-source tool suite for standardized risk and performance assessments at legacy nuclear waste sites. These assessments use a graded and iterative approach, beginning with simplified highly abstracted models, and adding geometric and geologic complexity as understanding is gained. To build confidence in this assessment capability, extensive testing of the underlying tools is needed. Since the tools themselves, such as the subsurface flow and reactive-transport simulator, Amanzi, are under active development, testing must be both hierarchical and highly automated. In this presentation we show how we have met these requirements, by leveraging the python-based open-source documentation system called Sphinx with several other open-source tools. Sphinx builds on the reStructured text tool docutils, with important extensions that include high-quality formatting of equations, and integrated plotting through matplotlib. This allows the documentation, as well as the input files for tests, benchmark and tutorial problems, to be maintained with the source code under a version control system. In addition, it enables developers to build documentation in several different formats (e.g., html and pdf) from a single source. We will highlight these features, and discuss important benefits of this approach for Amanzi. In addition, we'll show that some of ASCEM's other tools, such as the sampling provided by the Uncertainty Quantification toolset, are naturally leveraged to enable more comprehensive testing. Finally, we will highlight the integration of this hiearchical testing and documentation framework with our build system and tools (CMake, CTest, and CDash).

  8. Extensive validation of the pain disability index in 3 groups of patients with musculoskeletal pain.

    PubMed

    Soer, Remko; Köke, Albère J A; Vroomen, Patrick C A J; Stegeman, Patrick; Smeets, Rob J E M; Coppes, Maarten H; Reneman, Michiel F

    2013-04-20

    A cross-sectional study design was performed. To validate the pain disability index (PDI) extensively in 3 groups of patients with musculoskeletal pain. The PDI is a widely used and studied instrument for disability related to various pain syndromes, although there is conflicting evidence concerning factor structure, test-retest reliability, and missing items. Additionally, an official translation of the Dutch language version has never been performed. For reliability, internal consistency, factor structure, test-retest reliability and measurement error were calculated. Validity was tested with hypothesized correlations with pain intensity, kinesiophobia, Rand-36 subscales, Depression, Roland-Morris Disability Questionnaire, Quality of Life, and Work Status. Structural validity was tested with independent backward translation and approval from the original authors. One hundred seventy-eight patients with acute back pain, 425 patients with chronic low back pain and 365 with widespread pain were included. Internal consistency of the PDI was good. One factor was identified with factor analyses. Test-retest reliability was good for the PDI (intraclass correlation coefficient, 0.76). Standard error of measurement was 6.5 points and smallest detectable change was 17.9 points. Little correlations between the PDI were observed with kinesiophobia and depression, fair correlations with pain intensity, work status, and vitality and moderate correlations with the Rand-36 subscales and the Roland-Morris Disability Questionnaire. The PDI-Dutch language version is internally consistent as a 1-factor structure, and test-retest reliable. Missing items seem high in sexual and professional items. Using the PDI as a 2-factor questionnaire has no additional value and is unreliable.

  9. Theme--Teaming Up: Agricultural Education and Cooperative Extension.

    ERIC Educational Resources Information Center

    Gamon, Julia A.; And Others

    1994-01-01

    Includes "Similarities and Differences" (Gamon); "Preparing Agriculture Teachers and Extension Agents" (Seevers); "Teaching and Extension" (Graham); "Cooperation between 4-H and FFA" (Hink); "Team Approach to Agricultural and Extension Education in Georgia" (Iverson, Rohs); "Agricultural…

  10. Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures

    NASA Technical Reports Server (NTRS)

    Groll, M.; Pittman, R. B.; Eninger, J. E.

    1975-01-01

    A recently developed, potentially high-performance nonarterial wick has been extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 K and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: (1) maximum heat pipe performance as a function of fluid inventory, (2) maximum performance as a function of operating temperature, (3) maximum performance as a function of evaporator elevation, and (4) influence of slab wick orientation on performance. The experimental data was compared with theoretical predictions obtained with the computer program GRADE.

  11. Aerodynamic/acoustic performance of YJ101/double bypass VCE with coannular plug nozzle

    NASA Technical Reports Server (NTRS)

    Vdoviak, J. W.; Knott, P. R.; Ebacker, J. J.

    1981-01-01

    Results of a forward Variable Area Bypass Injector test and a Coannular Nozzle test performed on a YJ101 Double Bypass Variable Cycle Engine are reported. These components are intended for use on a Variable Cycle Engine. The forward Variable Area Bypass Injector test demonstrated the mode shifting capability between single and double bypass operation with less than predicted aerodynamic losses in the bypass duct. The acoustic nozzle test demonstrated that coannular noise suppression was between 4 and 6 PNdB in the aft quadrant. The YJ101 VCE equipped with the forward VABI and the coannular exhaust nozzle performed as predicted with exhaust system aerodynamic losses lower than predicted both in single and double bypass modes. Extensive acoustic data were collected including far field, near field, sound separation/ internal probe measurements as Laser Velocimeter traverses.

  12. A gas flow indicator for portable life support systems

    NASA Technical Reports Server (NTRS)

    Bass, R. L., III; Schroeder, E. C.

    1975-01-01

    A three-part program was conducted to develop a gas flow indicator (GFI) to monitor ventilation flow in a portable life support system. The first program phase identified concepts which could potentially meet the GFI requirements. In the second phase, a working breadboard GFI, based on the concept of a pressure sensing diaphragm-aneroid assembly connected to a venturi, was constructed and tested. Extensive testing of the breadboard GFI indicated that the design would meet all NASA requirements including eliminating problems experienced with the ventilation flow sensor used in the Apollo program. In the third program phase, an optimized GFI was designed by utilizing test data obtained on the breadboard unit. A prototype unit was constructed using prototype materials and fabrication techniques, and performance tests indicated that the prototype GFI met or exceeded all requirements.

  13. Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures. [methane and ethane working fluids

    NASA Technical Reports Server (NTRS)

    Groll, M.; Pittman, R. B.; Eninger, J. E.

    1976-01-01

    A recently developed, potentially high-performance nonarterial wick was extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: maximum heat pipe performance as a function of fluid inventory, maximum performance as a function of operating temperature, maximum performance as a function of evaporator elevation, and influence of slab wick orientation on performance. The experimental data were compared with theoretical predictions obtained with the GRADE computer program.

  14. Verification Test for Ultra-Light Deployment Mechanism for Sectioned Deployable Antenna Reflectors

    NASA Astrophysics Data System (ADS)

    Zajac, Kai; Schmidt, Tilo; Schiller, Marko; Seifart, Klaus; Schmalbach, Matthias; Scolamiero, Lucio

    2013-09-01

    The ultra-light deployment mechanism (UDM) is based on three carbon fibre reinforced plastics (CFRP) curved tape springs made of carbon fibre / cyanate ester prepregs.In the frame of the activity its space application suitability for the deployment of solid reflector antenna sections was investigated. A projected diameter of the full reflector of 4 m to 7 m and specific mass in the order of magnitude of 2.6kg/m2 was focused for requirement derivation.Extensive verification tests including health checks, environmental and functional tests were carried out with an engineering model to enable representative characterizing of the UDM unit.This paper presents the design and a technical description of the UDM as well as a summary of achieved development status with respect to test results and possible design improvements.

  15. An Index and Test of Linear Moderated Mediation.

    PubMed

    Hayes, Andrew F

    2015-01-01

    I describe a test of linear moderated mediation in path analysis based on an interval estimate of the parameter of a function linking the indirect effect to values of a moderator-a parameter that I call the index of moderated mediation. This test can be used for models that integrate moderation and mediation in which the relationship between the indirect effect and the moderator is estimated as linear, including many of the models described by Edwards and Lambert ( 2007 ) and Preacher, Rucker, and Hayes ( 2007 ) as well as extensions of these models to processes involving multiple mediators operating in parallel or in serial. Generalization of the method to latent variable models is straightforward. Three empirical examples describe the computation of the index and the test, and its implementation is illustrated using Mplus and the PROCESS macro for SPSS and SAS.

  16. Preparation of an oakmoss absolute with reduced allergenic potential.

    PubMed

    Ehret, C; Maupetit, P; Petrzilka, M; Klecak, G

    1992-06-01

    Synopsis Oakmoss absolute, an extract of the lichen Evernia prunastri, is known to cause allergenic skin reactions due to the presence of certain aromatic aldehydes such as atranorin, chloratranorin, ethyl hematommate and ethyl chlorohematommate. In this paper it is shown that treatment of Oakmoss absolute with amino acids such as lysine and/or leucine, lowers considerably the content of these allergenic constituents including atranol and chloratranol. The resulting Oakmoss absolute, which exhibits an excellent olfactive quality, was tested extensively in comparative studies on guinea pigs and on man. The results of the Guinea Pig Maximization Test (GPMT) and Human Repeated Insult Patch Test (HRIPT) indicate that, in comparison with the commercial test sample, the allergenicity of this new quality of Oakmoss absolute was considerably reduced, and consequently better skin tolerance of this fragrance for man was achieved.

  17. Integration and Test for Small Shuttle Payloads

    NASA Technical Reports Server (NTRS)

    Wright, Michael R.; Day, John H. (Technical Monitor)

    2001-01-01

    Recommended approaches for shuttle small payload integration and test (I&T) are presented. The paper is intended for consideration by developers of small shuttle payloads, including I&T managers, project managers, and system engineers. Examples and lessons learned are presented based on the extensive history of the NASA's Hitchhiker project. All aspects of I&T are presented, including: (1) I&T team responsibilities, coordination, and communication; (2) Flight hardware handling practices; (3) Documentation and configuration management; (4) I&T considerations for payload development; (5) I&T at the development facility; (6) Prelaunch operations, transfer, orbiter integration, and interface testing; and (7) Postflight operations. This paper is of special interest to those payload projects which have small budgets and few resources: That is, the truly 'faster, cheaper, better' projects. All shuttle small payload developers are strongly encouraged to apply these guidelines during I&T planning and ground operations to take full advantage of today's limited resources and to help ensure mission success.

  18. Cladonia lichens on extensive green roofs: evapotranspiration, substrate temperature, and albedo.

    PubMed

    Heim, Amy; Lundholm, Jeremy

    2013-01-01

    Green roofs are constructed ecosystems that provide ecosystem services in urban environments. Shallow substrate green roofs subject the vegetation layer to desiccation and other environmental extremes, so researchers have evaluated a variety of stress-tolerant vegetation types for green roof applications. Lichens can be found in most terrestrial habitats.  They are able to survive extremely harsh conditions, including frequent cycles of desiccation and rehydration, nutrient-poor soil, fluctuating temperatures, and high UV intensities. Extensive green roofs (substrate depth <20cm) exhibit these harsh conditions, making lichens possible candidates for incorporation into the vegetation layer on extensive green roofs.  In a modular green roof system, we tested the effect of Cladonia lichens on substrate temperature, water loss, and albedo compared to a substrate-only control. Overall, the Cladonia modules had significantly cooler substrate temperatures during the summer and significantly warmer temperatures during the fall.  Additionally, the Cladonia modules lost significantly less water than the substrate-only control. This implies that they may be able to benefit neighboring vascular plant species by reducing water loss and maintaining favorable substrate temperatures.

  19. First results from the TUS orbital detector in the extensive air shower mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khrenov, B.A.; Klimov, P.A.; Panasyuk, M.I.

    TUS (Tracking Ultraviolet Set-up), the first orbital detector of extreme energy cosmic rays (EECRs), those with energies above 50 EeV, was launched into orbit on April 28, 2016, as a part of the Lomonosov satellite scientific payload. The main aim of the mission is to test a technique of registering fluorescent and Cherenkov radiation of extensive air showers generated by EECRs in the atmosphere with a space telescope. We present preliminary results of its operation in a mode dedicated to registering extensive air showers in the period from August 16, 2016, to November 4, 2016. No EECRs have been conclusivelymore » identified in the data yet, but the diversity of ultraviolet emission in the atmosphere was found to be unexpectedly rich. We discuss typical examples of data obtained with TUS and their possible origin. The data is important for obtaining more accurate estimates of the nocturnal ultraviolet glow of the atmosphere, necessary for successful development of more advanced orbital EECR detectors including those of the KLYPVE (K-EUSO) and JEM-EUSO missions.« less

  20. Additional extensions to the NASCAP computer code, volume 2

    NASA Technical Reports Server (NTRS)

    Stannard, P. R.; Katz, I.; Mandell, M. J.

    1982-01-01

    Particular attention is given to comparison of the actural response of the SCATHA (Spacecraft Charging AT High Altitudes) P78-2 satellite with theoretical (NASCAP) predictions. Extensive comparisons for a variety of environmental conditions confirm the validity of the NASCAP model. A summary of the capabilities and range of validity of NASCAP is presented, with extensive reference to previously published applications. It is shown that NASCAP is capable of providing quantitatively accurate results when the object and environment are adequately represented and fall within the range of conditions for which NASCAP was intended. Three dimensional electric field affects play an important role in determining the potential of dielectric surfaces and electrically isolated conducting surfaces, particularly in the presence of artificially imposed high voltages. A theory for such phenomena is presented and applied to the active control experiments carried out in SCATHA, as well as other space and laboratory experiments. Finally, some preliminary work toward modeling large spacecraft in polar Earth orbit is presented. An initial physical model is presented including charge emission. A simple code based upon the model is described along with code test results.

  1. Susceptibility Testing of Extensively Drug-Resistant and Pre-Extensively Drug-Resistant Mycobacterium tuberculosis against Levofloxacin, Linezolid, and Amoxicillin-Clavulanate

    PubMed Central

    Ahmed, Imran; Jabeen, Kauser; Inayat, Raunaq

    2013-01-01

    Pakistan is a high-burden country for tuberculosis (TB). The emergence and increasing incidence of extensively drug-resistant (XDR) TB has been reported in Pakistan. Similarly, the prevalence of multidrug-resistant TB infections with fluoroquinolone resistance (pre-XDR) is also increasing. To treat these infections, local drug susceptibility patterns of alternate antituberculosis agents, including levofloxacin (LVX), linezolid (LZD), and amoxicillin-clavulanate (AMC), is urgently needed. The aim of this study was to determine the susceptibility frequencies of drug-resistant (DR) Mycobacterium tuberculosis against LVX, LZD, and AMC. All susceptibilities were determined on Middlebrook 7H10 agar. A critical concentration was used for LVX (1 μg/ml), whereas MICs were determined for LZD and AMC. M. tuberculosis H37Rv was used as a control strain. A total of 102 M. tuberculosis isolates (XDR, n = 59; pre-XDR, n = 43) were tested. Resistance to LVX was observed in 91.2% (93/102). Using an MIC value of 0.5 μg/ml as a cutoff, resistance to LZD (MIC ≥ 1 μg/ml) was noted in 5.9% (6/102). Although the sensitivity breakpoints are not established for AMC, the MIC values were high (>16 μg/ml) in 97.1% (99/102). Our results demonstrate that LZD may be effective for the treatment of XDR and pre-XDR cases from Pakistan. High resistance rates against LVX in our study suggest the use of this drug with caution for DR-TB cases from this area. Drug susceptibility testing against LVX and AMC may be helpful in complicated and difficult-to-manage cases. PMID:23507286

  2. Susceptibility testing of extensively drug-resistant and pre-extensively drug-resistant Mycobacterium tuberculosis against levofloxacin, linezolid, and amoxicillin-clavulanate.

    PubMed

    Ahmed, Imran; Jabeen, Kauser; Inayat, Raunaq; Hasan, Rumina

    2013-06-01

    Pakistan is a high-burden country for tuberculosis (TB). The emergence and increasing incidence of extensively drug-resistant (XDR) TB has been reported in Pakistan. Similarly, the prevalence of multidrug-resistant TB infections with fluoroquinolone resistance (pre-XDR) is also increasing. To treat these infections, local drug susceptibility patterns of alternate antituberculosis agents, including levofloxacin (LVX), linezolid (LZD), and amoxicillin-clavulanate (AMC), is urgently needed. The aim of this study was to determine the susceptibility frequencies of drug-resistant (DR) Mycobacterium tuberculosis against LVX, LZD, and AMC. All susceptibilities were determined on Middlebrook 7H10 agar. A critical concentration was used for LVX (1 μg/ml), whereas MICs were determined for LZD and AMC. M. tuberculosis H37Rv was used as a control strain. A total of 102 M. tuberculosis isolates (XDR, n = 59; pre-XDR, n = 43) were tested. Resistance to LVX was observed in 91.2% (93/102). Using an MIC value of 0.5 μg/ml as a cutoff, resistance to LZD (MIC ≥ 1 μg/ml) was noted in 5.9% (6/102). Although the sensitivity breakpoints are not established for AMC, the MIC values were high (>16 μg/ml) in 97.1% (99/102). Our results demonstrate that LZD may be effective for the treatment of XDR and pre-XDR cases from Pakistan. High resistance rates against LVX in our study suggest the use of this drug with caution for DR-TB cases from this area. Drug susceptibility testing against LVX and AMC may be helpful in complicated and difficult-to-manage cases.

  3. The effect of hip abduction on the EMG activity of vastus medialis obliquus, vastus lateralis longus and vastus lateralis obliquus in healthy subjects

    PubMed Central

    Bevilaqua-Grossi, Débora; Monteiro-Pedro, Vanessa; de Vasconcelos, Rodrigo Antunes; Arakaki, Juliano Coelho; Bérzin, Fausto

    2006-01-01

    Study design Controlled laboratory study. Objectives The purposes of this paper were to investigate (d) whether vastus medialis obliquus (VMO), vastus lateralis longus (VLL) and vastus lateralis obliquus (VLO) EMG activity can be influenced by hip abduction performed by healthy subjects. Background Some clinicians contraindicate hip abduction for patellofemoral patients (with) based on the premise that hip abduction could facilitate the VLL muscle activation leading to a VLL and VMO imbalance Methods and measures Twenty-one clinically healthy subjects were involved in the study, 10 women and 11 men (aged X = 23.3 ± 2.9). The EMG signals were collected using a computerized EMG VIKING II, with 8 channels and three pairs of surface electrodes. EMG activity was obtained from MVIC knee extension at 90° of flexion in a seated position and MVIC hip abduction at 0° and 30° with patients in side-lying position with the knee in full extension. The data were normalized in the MVIC knee extension at 50° of flexion in a seated position, and were submitted to ANOVA test with subsequent application of the Bonferroni multiple comparisons analysis test. The level of significance was defined as p ≤ 0.05. Results The VLO muscle demonstrated a similar pattern to the VMO muscle showing higher EMG activity in MVIC knee extension at 90° of flexion compared with MVIC hip abduction at 0° and 30° of abduction for male (p < 0.0007) and MVIC hip abduction at 0° of abduction for female subjects (p < 0.02196). There were no statistically significant differences in the VLL EMG activity among the three sets of exercises tested. Conclusion The results showed that no selective EMG activation was observed when comparison was made between the VMO, VLL and VLO muscles while performing MVIC hip abduction at 0° and 30° of abduction and MVIC knee extension at 90° of flexion in both male and female subjects. Our findings demonstrate that hip abduction do not facilitated VLL and VLO activity in relation to the VMO, however, this study included only healthy subjects performing maximum voluntary isometric contraction contractions, therefore much remains to be discovered by future research PMID:16817971

  4. Teaching Human Digestion and pH Using Technology

    ERIC Educational Resources Information Center

    Kim, Hanna

    2008-01-01

    Testing the pH of various liquids is one of the most popular activities in 5th- through 8th-grade classrooms. The author presents an extensive pH-testing lesson based on a 5E (engagement, exploration, explanation, extension, and evaluation) teaching model. The activity provides students with the opportunity to learn about pH and how it relates to…

  5. Aerodynamic characteristics of a high-wing transport configuration with a over-the-wing nacelle-pylon arrangement

    NASA Technical Reports Server (NTRS)

    Henderson, W. P.; Abeyounis, W. K.

    1985-01-01

    An investigation has been conducted in the Langley 16-Foot Transonic Tunnel to determine the effects on the aerodynamic characteristics of a high-wing transport configuration of installing an over-the-wing nacelle-pylon arrangement. The tests are conducted at Mach numbers from 0.70 to 0.82 and at angles of attack from -2 deg to 4 deg. The configurational variables under study include symmetrical and contoured nacelles and pylons, pylon size, and wing leading-edge extensions. The symmetrical nacelles and pylons reduce the lift coefficient, increase the drag coefficient, and cause a nose-up pitching-moment coefficient. The contoured nacelles significantly reduce the interference drag, though it is still excessive. Increasing the pylon size reduces the drag, whereas adding wing leading-edge extension does not affect the aerodynamic characteristics significantly.

  6. UTCI-Fiala multi-node model of human heat transfer and temperature regulation

    NASA Astrophysics Data System (ADS)

    Fiala, Dusan; Havenith, George; Bröde, Peter; Kampmann, Bernhard; Jendritzky, Gerd

    2012-05-01

    The UTCI-Fiala mathematical model of human temperature regulation forms the basis of the new Universal Thermal Climate Index (UTC). Following extensive validation tests, adaptations and extensions, such as the inclusion of an adaptive clothing model, the model was used to predict human temperature and regulatory responses for combinations of the prevailing outdoor climate conditions. This paper provides an overview of the underlying algorithms and methods that constitute the multi-node dynamic UTCI-Fiala model of human thermal physiology and comfort. Treated topics include modelling heat and mass transfer within the body, numerical techniques, modelling environmental heat exchanges, thermoregulatory reactions of the central nervous system, and perceptual responses. Other contributions of this special issue describe the validation of the UTCI-Fiala model against measured data and the development of the adaptive clothing model for outdoor climates.

  7. Brief Report: An Independent Replication and Extension of Psychometric Evidence Supporting the Theory of Mind Inventory.

    PubMed

    Greenslade, Kathryn J; Coggins, Truman E

    2016-08-01

    This study presents an independent replication and extension of psychometric evidence supporting the Theory of Mind Inventory (ToMI). Parents of 20 children with ASD (4; 1-6; 7 years; months) and 20 with typical development (3; 1-6; 5), rated their child's theory of mind abilities in everyday situations. Other parent report and child behavioral assessments included the Social Responsiveness Scale-2, Vineland Adaptive Behavior Scales-2, Peabody Picture Vocabulary Test-4, and Clinical Evaluation of Language Fundamentals-Preschool, 2. Results revealed high internal consistency, expected developmental changes in children with typical development, expected group differences between children with and without ASD, and strong correlations with other measures of social and communication abilities. The ToMI demonstrates strong psychometrics, suggesting considerable utility in identifying theory of mind deficits in children with ASD.

  8. A comparison of manual and quantitative elbow strength testing.

    PubMed

    Shahgholi, Leili; Bengtson, Keith A; Bishop, Allen T; Shin, Alexander Y; Spinner, Robert J; Basford, Jeffrey R; Kaufman, Kenton R

    2012-10-01

    The aim of this study was to compare the clinical ratings of elbow strength obtained by skilled clinicians with objective strength measurement obtained through quantitative testing. A retrospective comparison of subject clinical records with quantitative strength testing results in a motion analysis laboratory was conducted. A total of 110 individuals between the ages of 8 and 65 yrs with traumatic brachial plexus injuries were identified. Patients underwent manual muscle strength testing as assessed on the 5-point British Medical Research Council Scale (5/5, normal; 0/5, absent) and quantitative elbow flexion and extension strength measurements. A total of 92 subjects had elbow flexion testing. Half of the subjects clinically assessed as having normal (5/5) elbow flexion strength on manual muscle testing exhibited less than 42% of their age-expected strength on quantitative testing. Eighty-four subjects had elbow extension strength testing. Similarly, half of those displaying normal elbow extension strength on manual muscle testing were found to have less than 62% of their age-expected values on quantitative testing. Significant differences between manual muscle testing and quantitative findings were not detected for the lesser (0-4) strength grades. Manual muscle testing, even when performed by experienced clinicians, may be more misleading than expected for subjects graded as having normal (5/5) strength. Manual muscle testing estimates for the lesser strength grades (1-4/5) seem reasonably accurate.

  9. A dynamic motion simulator for future European docking systems

    NASA Technical Reports Server (NTRS)

    Brondino, G.; Marchal, PH.; Grimbert, D.; Noirault, P.

    1990-01-01

    Europe's first confrontation with docking in space will require extensive testing to verify design and performance and to qualify hardware. For this purpose, a Docking Dynamics Test Facility (DDTF) was developed. It allows reproduction on the ground of the same impact loads and relative motion dynamics which would occur in space during docking. It uses a 9 degree of freedom, servo-motion system, controlled by a real time computer, which simulates the docking spacecraft in a zero-g environment. The test technique involves and active loop based on six axis force and torque detection, a mathematical simulation of individual spacecraft dynamics, and a 9 degree of freedom servomotion of which 3 DOFs allow extension of the kinematic range to 5 m. The configuration was checked out by closed loop tests involving spacecraft control models and real sensor hardware. The test facility at present has an extensive configuration that allows evaluation of both proximity control and docking systems. It provides a versatile tool to verify system design, hardware items and performance capabilities in the ongoing HERMES and COLUMBUS programs. The test system is described and its capabilities are summarized.

  10. Linking Research, Extension and Farmers: The Case of Mangrove Swamp Rice Cultivation in Sierra Leone.

    ERIC Educational Resources Information Center

    Zinnah, Moses Moroe

    1994-01-01

    Interviews with 124 rice farmers in Sierra Leone revealed that farmers and extension staff have minimal participation and input in testing of new cultivation technologies. The top-down research approach has limited contact among researchers, extension staff, and farmers and affected the utility and application of research. (SK)

  11. Power Extension Package (PEP) system definition extension, orbital service module systems analysis study. Volume 12: PEP data item descriptions

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Contractor information requirements necessary to support the power extension package project of the space shuttle program are specified for the following categories of data: project management; configuration management; systems engineering and test; manufacturing; reliability, quality assurance and safety; logistics; training; and operations.

  12. The Intelligent System of Cardiovascular Disease Diagnosis Based on Extension Data Mining

    NASA Astrophysics Data System (ADS)

    Sun, Baiqing; Li, Yange; Zhang, Lin

    This thesis gives the general definition of the concepts of extension knowledge, extension data mining and extension data mining theorem in high dimension space, and also builds the IDSS integrated system by the rough set, expert system and neural network, develops the relevant computer software. From the diagnosis tests, according to the common diseases of myocardial infarctions, angina pectoris and hypertension, and made the test result with physicians, the results shows that the sensitivity, specific and accuracy diagnosis by the IDSS are all higher than the physicians. It can improve the rate of the accuracy diagnosis of physician with the auxiliary help of this system, which have the obvious meaning in low the mortality, disability rate and high the survival rate, and has strong practical values and further social benefits.

  13. Pretest predictions for degraded shutdown heat-removal tests in THORS-SHRS Assembly 1. [LMFBR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rose, S.D.; Carbajo, J.J.

    The recent modification of the Thermal-Hydraulic Out-of-Reactor Safety (THORS) facility at ORNL will allow testing of parallel simulated fuel assemblies under natural-convection and low-flow forced-convection conditions similar to those that might occur during a partial failure of the Shutdown Heat Removal System (SHRS) of an LMFBR. An extensive test program has been prepared and testing will be started in September 1983. THORS-SHRS Assembly 1 consists of two 19-pin bundles in parallel with a third leg serving as a bypass line and containing a sodium-to-sodium intermediate heat exchanger. Testing at low powers wil help indicate the maximum amount of heat thatmore » can be removed from the reactor core during conditions of degraded shutdown heat removal. The thermal-hydraulic behavior of the test bundles will be characterized for single-phase and two-phase conditions up to dryout. The influence of interassembly flow redistribution including transients from forced- to natural-convection conditions will be investigated during testing.« less

  14. Occupant Responses in a Full-Scale Crash Test of the Sikorsky ACAP Helicopter

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Fasanella, Edwin L.; Boitnott, Richard L.; McEntire, Joseph; Lewis, Alan

    2002-01-01

    A full-scale crash test of the Sikorsky Advanced Composite Airframe Program (ACAP) helicopter was performed in 1999 to generate experimental data for correlation with a crash simulation developed using an explicit nonlinear, transient dynamic finite element code. The airframe was the residual flight test hardware from the ACAP program. For the test, the aircraft was outfitted with two crew and two troop seats, and four anthropomorphic test dummies. While the results of the impact test and crash simulation have been documented fairly extensively in the literature, the focus of this paper is to present the detailed occupant response data obtained from the crash test and to correlate the results with injury prediction models. These injury models include the Dynamic Response Index (DRI), the Head Injury Criteria (HIC), the spinal load requirement defined in FAR Part 27.562(c), and a comparison of the duration and magnitude of the occupant vertical acceleration responses with the Eiband whole-body acceleration tolerance curve.

  15. Reliability and measurement error of active knee extension range of motion in a modified slump test position: a pilot study.

    PubMed

    Tucker, Neil; Reid, Duncan; McNair, Peter

    2007-01-01

    The slump test is a tool to assess the mechanosensitivity of the neuromeningeal structures within the vertebral canal. While some studies have investigated the reliability of aspects of this test within the same day, few have assessed the reliability across days. Therefore, the purpose of this pilot study was to investigate reliability when measuring active knee extension range of motion (AROM) in a modified slump test position within trials on a single day and across days. Ten male and ten female asymptomatic subjects, ages 20-49 (mean age 30.1, SD 6.4) participated in the study. Knee extension AROM in a modified slump position with the cervical spine in a flexed position and then in an extended position was measured via three trials on two separate days. Across three trials, knee extension AROM increased significantly with a mean magnitude of 2 degrees within days for both cervical spine positions (P>0.05). The findings showed that there was no statistically significant difference in knee extension AROM measurements across days (P>0.05). The intraclass correlation coefficients for the mean of the three trials across days were 0.96 (lower limit 95% CI: 0.90) with the cervical spine flexed and 0.93 (lower limit 95% CI: 0.83) with cervical extension. Measurement error was calculated by way of the typical error and 95% limits of agreement, and visually represented in Bland and Altman plots. The typical error for the cervical flexed and extended positions averaged across trials was 2.6 degrees and 3.3 degrees , respectively. The limits of agreement were narrow, and the Bland and Altman plots also showed minimal bias in the joint angles across days with a random distribution of errors across the range of measured angles. This study demonstrated that knee extension AROM could be reliably measured across days in subjects without pathology and that the measurement error was acceptable. Implications of variability over multiple trials are discussed. The modified set-up for the test using the Kincom dynamometer and elevated thigh position may be useful to clinical researchers in determining the mechanosensitivity of the nervous system.

  16. Reliability and Measurement Error of Active Knee Extension Range of Motion in a Modified Slump Test Position: A Pilot Study

    PubMed Central

    Tucker, Neil; Reid, Duncan; McNair, Peter

    2007-01-01

    The slump test is a tool to assess the mechanosensitivity of the neuromeningeal structures within the vertebral canal. While some studies have investigated the reliability of aspects of this test within the same day, few have assessed the reliability across days. Therefore, the purpose of this pilot study was to investigate reliability when measuring active knee extension range of motion (AROM) in a modified slump test position within trials on a single day and across days. Ten male and ten female asymptomatic subjects, ages 20–49 (mean age 30.1, SD 6.4) participated in the study. Knee extension AROM in a modified slump position with the cervical spine in a flexed position and then in an extended position was measured via three trials on two separate days. Across three trials, knee extension AROM increased significantly with a mean magnitude of 2° within days for both cervical spine positions (P>0.05). The findings showed that there was no statistically significant difference in knee extension AROM measurements across days (P>0.05). The intraclass correlation coefficients for the mean of the three trials across days were 0.96 (lower limit 95% CI: 0.90) with the cervical spine flexed and 0.93 (lower limit 95% CI: 0.83) with cervical extension. Measurement error was calculated by way of the typical error and 95% limits of agreement, and visually represented in Bland and Altman plots. The typical error for the cervical flexed and extended positions averaged across trials was 2.6° and 3.3°, respectively. The limits of agreement were narrow, and the Bland and Altman plots also showed minimal bias in the joint angles across days with a random distribution of errors across the range of measured angles. This study demonstrated that knee extension AROM could be reliably measured across days in subjects without pathology and that the measurement error was acceptable. Implications of variability over multiple trials are discussed. The modified set-up for the test using the Kincom dynamometer and elevated thigh position may be useful to clinical researchers in determining the mechanosensitivity of the nervous system. PMID:19066666

  17. New Focuses on European Extension Education: The Issues. Proceedings of the European Seminar on Extension Education (10th, Vila Real, Portugal, September 1-9, 1991).

    ERIC Educational Resources Information Center

    Koehnen, Timothy, Ed.; Cristovao, Artur, Ed.

    This proceedings report is organized into four sections dealing respectively with: (1) global issues facing extension education; (2) extension strategies and methods; (3) extension planning and evaluation; and (4) training and curriculum development. The following papers are included: "Extension Science: To Broaden the Scope" (van…

  18. An Overview of Controls and Flying Qualities Technology on the F/A-18 High Alpha Research Vehicle

    NASA Technical Reports Server (NTRS)

    Pahle, Joseph W.; Wichman, Keith D.; Foster, John V.; Bundick, W. Thomas

    1996-01-01

    The NASA F/A-18 High Alpha Research Vehicle (HARV) has been the flight test bed of a focused technology effort to significantly increase maneuvering capability at high angles of attack. Development and flight test of control law design methodologies, handling qualities metrics, performance guidelines, and flight evaluation maneuvers are described. The HARV has been modified to include two research control effectors, thrust vectoring, and actuated forebody strakes in order to provide increased control power at high angles of attack. A research flight control system has been used to provide a flexible, easily modified capability for high-angle-of-attack research controls. Different control law design techniques have been implemented and flight-tested, including eigenstructure assignment, variable gain output feedback, pseudo controls, and model-following. Extensive piloted simulation has been used to develop nonlinear performance guide-lines and handling qualities criteria for high angles of attack. This paper reviews the development and evaluation of technologies useful for high-angle-of-attack control. Design, development, and flight test of the research flight control system, control laws, flying qualities specifications, and flight test maneuvers are described. Flight test results are used to illustrate some of the lessons learned during flight test and handling qualities evaluations.

  19. Algorithm optimization for multitined radiofrequency ablation: comparative study in ex vivo and in vivo bovine liver.

    PubMed

    Appelbaum, Liat; Sosna, Jacob; Pearson, Robert; Perez, Sarah; Nissenbaum, Yizhak; Mertyna, Pawel; Libson, Eugene; Goldberg, S Nahum

    2010-02-01

    To prospectively optimize multistep algorithms for largest available multitined radiofrequency (RF) electrode system in ex vivo and in vivo tissues, to determine best energy parameters to achieve large predictable target sizes of coagulation, and to compare these algorithms with manufacturer's recommended algorithms. Institutional animal care and use committee approval was obtained for the in vivo portion of this study. Ablation (n = 473) was performed in ex vivo bovine liver; final tine extension was 5-7 cm. Variables in stepped-deployment RF algorithm were interrogated and included initial current ramping to 105 degrees C (1 degrees C/0.5-5.0 sec), the number of sequential tine extensions (2-7 cm), and duration of application (4-12 minutes) for final two to three tine extensions. Optimal parameters to achieve 5-7 cm of coagulation were compared with recommended algorithms. Optimal settings for 5- and 6-cm final tine extensions were confirmed in in vivo perfused bovine liver (n = 14). Multivariate analysis of variance and/or paired t tests were used. Mean RF ablation zones of 5.1 cm +/- 0.2 (standard deviation), 6.3 cm +/- 0.4, and 7 cm +/- 0.3 were achieved with 5-, 6-, and 7-cm final tine extensions in a mean of 19.5 min +/- 0.5, 27.9 min +/- 6, and 37.1 min +/- 2.3, respectively, at optimal settings. With these algorithms, size of ablation at 6- and 7-cm tine extension significantly increased from mean of 5.4 cm +/- 0.4 and 6.1 cm +/- 0.6 (manufacturer's algorithms) (P <.05, both comparisons); two recommended tine extensions were eliminated. In vivo confirmation produced mean diameter in specified time: 5.5 cm +/- 0.4 in 18.5 min +/- 0.5 (5-cm extensions) and 5.7 cm +/- 0.2 in 21.2 min +/- 0.6 (6-cm extensions). Large zones of coagulation of 5-7 cm can be created with optimized RF algorithms that help reduce number of tine extensions compared with manufacturer's recommendations. Such algorithms are likely to facilitate the utility of these devices for RF ablation of focal tumors in clinical practice. (c) RSNA, 2010.

  20. Remote sensing and field test capabilities at U.S. Army Dugway Proving Ground

    NASA Astrophysics Data System (ADS)

    Pearson, James T.; Herron, Joshua P.; Marshall, Martin S.

    2011-11-01

    U.S. Army Dugway Proving Ground (DPG) is a Major Range and Test Facility Base (MRTFB) with the mission of testing chemical and biological defense systems and materials. DPG facilities include state-of-the-art laboratories, extensive test grids, controlled environment calibration facilities, and a variety of referee instruments for required test measurements. Among these referee instruments, DPG has built up a significant remote sensing capability for both chemical and biological detection. Technologies employed for remote sensing include FTIR spectroscopy, UV spectroscopy, Raman-shifted eye-safe lidar, and other elastic backscatter lidar systems. These systems provide referee data for bio-simulants, chemical simulants, toxic industrial chemicals (TICs), and toxic industrial materials (TIMs). In order to realize a successful large scale open-air test, each type of system requires calibration and characterization. DPG has developed specific calibration facilities to meet this need. These facilities are the Joint Ambient Breeze Tunnel (JABT), and the Active Standoff Chamber (ASC). The JABT and ASC are open ended controlled environment tunnels. Each includes validation instrumentation to characterize simulants that are disseminated. Standoff systems are positioned at typical field test distances to measure characterized simulants within the tunnel. Data from different types of systems can be easily correlated using this method, making later open air test results more meaningful. DPG has a variety of large scale test grids available for field tests. After and during testing, data from the various referee instruments is provided in a visual format to more easily draw conclusions on the results. This presentation provides an overview of DPG's standoff testing facilities and capabilities, as well as example data from different test scenarios.

  1. Remote sensing and field test capabilities at U.S. Army Dugway Proving Ground

    NASA Astrophysics Data System (ADS)

    Pearson, James T.; Herron, Joshua P.; Marshall, Martin S.

    2012-05-01

    U.S. Army Dugway Proving Ground (DPG) is a Major Range and Test Facility Base (MRTFB) with the mission of testing chemical and biological defense systems and materials. DPG facilities include state-of-the-art laboratories, extensive test grids, controlled environment calibration facilities, and a variety of referee instruments for required test measurements. Among these referee instruments, DPG has built up a significant remote sensing capability for both chemical and biological detection. Technologies employed for remote sensing include FTIR spectroscopy, UV spectroscopy, Raman-shifted eye-safe lidar, and other elastic backscatter lidar systems. These systems provide referee data for bio-simulants, chemical simulants, toxic industrial chemicals (TICs), and toxic industrial materials (TIMs). In order to realize a successful large scale open-air test, each type of system requires calibration and characterization. DPG has developed specific calibration facilities to meet this need. These facilities are the Joint Ambient Breeze Tunnel (JABT), and the Active Standoff Chamber (ASC). The JABT and ASC are open ended controlled environment tunnels. Each includes validation instrumentation to characterize simulants that are disseminated. Standoff systems are positioned at typical field test distances to measure characterized simulants within the tunnel. Data from different types of systems can be easily correlated using this method, making later open air test results more meaningful. DPG has a variety of large scale test grids available for field tests. After and during testing, data from the various referee instruments is provided in a visual format to more easily draw conclusions on the results. This presentation provides an overview of DPG's standoff testing facilities and capabilities, as well as example data from different test scenarios.

  2. Recovery from Unrecognized Sleep Loss Accumulated in Daily Life Improved Mood Regulation via Prefrontal Suppression of Amygdala Activity

    PubMed Central

    Motomura, Yuki; Kitamura, Shingo; Nakazaki, Kyoko; Oba, Kentaro; Katsunuma, Ruri; Terasawa, Yuri; Hida, Akiko; Moriguchi, Yoshiya; Mishima, Kazuo

    2017-01-01

    Many modern people suffer from sleep debt that has accumulated in everyday life but is not subjectively noticed [potential sleep debt (PSD)]. Our hypothesis for this study was that resolution of PSD through sleep extension optimizes mood regulation by altering the functional connectivity between the amygdala and prefrontal cortex. Fifteen healthy male participants underwent an experiment consisting of a baseline (BL) evaluation followed by two successive interventions, namely, a 9-day sleep extension followed by one night of total sleep deprivation (TSD). Tests performed before and after the interventions included a questionnaire on negative mood and neuroimaging with arterial spin labeling MRI for evaluating regional cerebral blood flow (rCBF) and functional connectivity. Negative mood and amygdala rCBF were significantly reduced after sleep extension compared with BL. The amygdala had a significant negative functional connectivity with the medial prefrontal cortex (FCamg–MPFC), and this negative connectivity was greater after sleep extension than at BL. After TSD, these indices reverted to the same level as at BL. An additional path analysis with structural equation modeling showed that the FCamg–MPFC significantly explained the amygdala rCBF and that the amygdala rCBF significantly explained the negative mood. These findings suggest that the use of our sleep extension protocol normalized amygdala activity via negative amygdala–MPFC functional connectivity. The resolution of unnoticed PSD may improve mood by enhancing frontal suppression of hyperactivity in the amygdala caused by PSD accumulating in everyday life. PMID:28713328

  3. The effect of non-weight bearing group-exercising on females with non-specific chronic low back pain: a randomized single blind controlled pilot study.

    PubMed

    Masharawi, Youssef; Nadaf, Nedal

    2013-01-01

    The aim of this study was to investigate the effect of active non-weight-bearing (NWB) group exercising on women with non specific chronic low back pain (NSCLBP). Forty females with NSCLBP were assigned in a randomized control longitudinal single blinded pilot study. 20 of them were assigned to a NWB bi-weekly group exercise class and 20 females were included in the control group. The exercises involved the entire lumbo-pelvic spine aimed at improving lumbar mobility/flexibility and stability. Pain intensity (VAS), back specific disability (Rolland Morris questionnaire-RMQ), and lumbar flexion and extension ranges of motion measurements were taken prior to intervention (t(0)), immediately following 4 weeks of intervention (t(1)) and 8 weeks later (t(fu)). Reliability trials were conducted on 10 females. Non-parametric tests were used for statistical significance (p < 0.05). The following significant changes in outcome measures were indicated at t(1) compared with t(0) and control group (p < 0.001): an increase in lumbar flexion and extension (mean difference = 9.26◦ (+54%) for flexion and 5.95◦ for extension(+98%)); reduction in VAS score (mean difference = 2.32 (+58%)) and RMQ score (mean difference = 4.9 (−34%)). All changes remained significant at t(fu). At t(0), lumbar flexion was correlated with extension (r = 0.547) and VAS (r = −0.581),whereas the RMQ score correlated with VAS score (r = 0.599) and negatively with lumbar extension (r = −0.665). At t(1),lumbar flexion correlated with extension (r = 0.664) and negatively with RMQ score (r = −0.54). At t(fu), changes in VAS score were negatively correlated with changes in lumbar flexion (r = −0.522), while changes in lumbar flexion correlated with extension (r = 0.58). A functional program of NWB group exercising improves functional, painful status, lumbar flexion and extension ranges of motion in women suffering from NSCLBP.

  4. Fecal /sup 13/C analysis for the detection and quantitation of intestinal malabsorption

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, P.D.; MacLean, W.C. Jr.; Watkins, J.B.

    Use of /sup 14/CO/sub 2/ breath tests and fecal analyses for the detection and quantitation of intestinal malabsorption has been extensively documented in adult subjects. The use of radioisotopes has extended the range of breath test applications to include pediatric and geriatric subjects. Here we report a fecal /sup 13/C analysis that can be used in conjunction with /sup 14/CO/sub 2/ breath tests. Twenty-four-hour fecal samples were collected before and after the administration of a labeled substrate. Simultaneous cholyglycine /sup 13/CO/sub 2/ breath tests and fecal assays were performed in five children. One child with bacterial overgrowth had an abnormalmore » breath test and a normal fecal test. Of three children with ileal dysfunction, only one had an abnormal breath test, whereas the fecal test was abnormal in all three. Both the breath test and fecal test were abnormal for a child who had undergone an ileal resection. Both tests were normal for a child with ulcerative colitis.« less

  5. Energy Absorbing Seat System for an Agricultural Aircraft

    NASA Technical Reports Server (NTRS)

    Kellas, Sotiris; Jones, Lisa E. (Technical Monitor)

    2002-01-01

    A task was initiated to improve the energy absorption capability of an existing aircraft seat through cost-effective retrofitting, while keeping seat-weight increase to a minimum. This task was undertaken as an extension of NASA ongoing safety research and commitment to general aviation customer needs. Only vertical crash scenarios have been considered in this task which required the energy absorbing system to protect the seat occupant in a range of crash speeds up to 31 ft/sec. It was anticipated that, the forward and/or side crash accelerations could be attenuated with the aid of airbags, the technology of which is currently available in automobiles and military helicopters. Steps which were followed include, preliminary crush load determination, conceptual design of cost effective energy absorbers, fabrication and testing (static and dynamic) of energy absorbers, system analysis, design and fabrication of dummy seat/rail assembly, dynamic testing of dummy seat/rail assembly, and finally, testing of actual modified seat system with a dummy occupant. A total of ten full scale tests have been performed including three of the actual aircraft seat. Results from full-scale tests indicated that occupant loads were attenuated successfully to survivable levels.

  6. A comprehensive review of the psychometric properties of the Drug Abuse Screening Test.

    PubMed

    Yudko, Errol; Lozhkina, Olga; Fouts, Adriana

    2007-03-01

    This article reviews the reliability and the validity of the (10-, 20-, and 28-item) Drug Abuse Screening Test (DAST). The reliability and the validity of the adolescent version of the DAST are also reviewed. An extensive literature review was conducted using the Medline and Psychinfo databases from the years 1982 to 2005. All articles that addressed the reliability and the validity of the DAST were examined. Publications in which the DAST was used as a screening tool but had no data on its psychometric properties were not included. Descriptive information about each version of the test, as well as discussion of the empirical literature that has explored measures of the reliability and the validity of the DAST, has been included. The DAST tended to have moderate to high levels of test-retest, interitem, and item-total reliabilities. The DAST also tended to have moderate to high levels of validity, sensitivity, and specificity. In general, all versions of the DAST yield satisfactory measures of reliability and validity for use as clinical or research tools. Furthermore, these tests are easy to administer and have been used in a variety of populations.

  7. Primary ciliary dyskinesia: improving the diagnostic approach

    PubMed Central

    Leigh, Margaret W.; Zariwala, Maimoona A.; Knowles, Michael R.

    2009-01-01

    Purpose of review The diagnosis of primary ciliary dyskinesia (PCD) has relied on analysis of ciliary motility and ultrastructure; however, these tests are not readily available and have not been standardized. Consequently, the diagnosis of PCD may be delayed or missed or made incorrectly. This review outlines the potential utility of new diagnostic tests, including measurement of nasal nitric oxide (NO) production and systematic analysis for mutations in gene encoding ciliary proteins. Recent findings Clinical manifestations of PCD have been expanded to include neonatal respiratory distress and heterotaxy. Measurement of nasal NO has emerged as a useful screening test for PCD based on the very low levels in PCD (approximately 1/10 of normal values). Genetic testing is emerging for PCD and demonstrates extensive genetic heterogeneity. Some genes and gene mutations involved in PCD have been defined. Approximately one third of PCD cases have identifiable gene mutations in one of 6 different genes. An international effort is focused on defining PCD-causing defects in other genes. Summary The incorporation of nasal NO measurement as a screening test to define probable PCD cases and gene mutation analysis to make a definitive diagnosis of PCD should enhance diagnostic evaluation of PCD. PMID:19300264

  8. Maximum acceptable weight of lift reflects peak lumbosacral extension moments in a functional capacity evaluation test using free style, stoop and squat lifting.

    PubMed

    Kuijer, P P F M; van Oostrom, S H; Duijzer, K; van Dieën, J H

    2012-01-01

    It is unclear whether the maximum acceptable weight of lift (MAWL), a common psychophysical method, reflects joint kinetics when different lifting techniques are employed. In a within-participants study (n = 12), participants performed three lifting techniques--free style, stoop and squat lifting from knee to waist level--using the same dynamic functional capacity evaluation lifting test to assess MAWL and to calculate low back and knee kinetics. We assessed which knee and back kinetic parameters increased with the load mass lifted, and whether the magnitudes of the kinetic parameters were consistent across techniques when lifting MAWL. MAWL was significantly different between techniques (p = 0.03). The peak lumbosacral extension moment met both criteria: it had the highest association with the load masses lifted (r > 0.9) and was most consistent between the three techniques when lifting MAWL (ICC = 0.87). In conclusion, MAWL reflects the lumbosacral extension moment across free style, stoop and squat lifting in healthy young males, but the relation between the load mass lifted and lumbosacral extension moment is different between techniques. Tests of maximum acceptable weight of lift (MAWL) from knee to waist height are used to assess work capacity of individuals with low-back disorders. This article shows that the MAWL reflects the lumbosacral extension moment across free style, stoop and squat lifting in healthy young males, but the relation between the load mass lifted and lumbosacral extension moment is different between techniques. This suggests that standardisation of lifting technique used in tests of the MAWL would be indicated if the aim is to assess the capacity of the low back.

  9. Characteristics, Views Held of Agricultural Extension Activities, and Communication Behavior of Hsien Extension Supervisors in Taiwan.

    ERIC Educational Resources Information Center

    Hong, Pi-Feng

    Government agencies in Taiwan have carried out agricultural extension programs since 1910, with the assistance of Farmers' Associations. Programs have been expanded since 1953, and now include both general extension (subsidy programs) and educational extension. Comparison of personal characteristics of hsien (county) Farmers' Association…

  10. Building an Agricultural Extension Services System Supported by ICTs in Tanzania: Progress Made, Challenges Remain

    ERIC Educational Resources Information Center

    Sanga, C.; Kalungwizi, V. J.; Msuya, C. P.

    2013-01-01

    The conventional agricultural extension service in Tanzania is mainly provided by extension officers visiting farmers to provide agricultural advisory service. This system of extension service provision faces a number of challenges including the few number of extension officers and limited resources. This article assesses the effectiveness of an…

  11. Structural measurements and cell line studies of the copper-PEG-Rifampicin complex against Mycobacterium tuberculosis.

    PubMed

    Manning, Thomas; Mikula, Rachel; Wylie, Greg; Phillips, Dennis; Jarvis, Jackie; Zhang, Fengli

    2015-02-01

    The bacterium responsible for tuberculosis is increasing its resistance to antibiotics resulting in new multidrug-resistant Mycobacterium tuberculosis (MDR-TB) and extensively drug-resistant tuberculosis (XDR-TB). In this study, several analytical techniques including NMR, FT-ICR, MALDI-MS, LC-MS and UV/Vis are used to study the copper-Rifampicin-Polyethylene glycol (PEG-3350) complex. The copper (II) cation is a carrier for the antibiotic Rifampicin as well as nutrients for the bacterium. The NIH-NIAID cell line containing several Tb strains (including antibiotic resistant strains) is tested against seven copper-PEG-RIF complex variations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Preserved Self-Awareness following Extensive Bilateral Brain Damage to the Insula, Anterior Cingulate, and Medial Prefrontal Cortices

    PubMed Central

    Khalsa, Sahib S.; Damasio, Antonio; Tranel, Daniel; Landini, Gregory; Williford, Kenneth

    2012-01-01

    It has been proposed that self-awareness (SA), a multifaceted phenomenon central to human consciousness, depends critically on specific brain regions, namely the insular cortex, the anterior cingulate cortex (ACC), and the medial prefrontal cortex (mPFC). Such a proposal predicts that damage to these regions should disrupt or even abolish SA. We tested this prediction in a rare neurological patient with extensive bilateral brain damage encompassing the insula, ACC, mPFC, and the medial temporal lobes. In spite of severe amnesia, which partially affected his “autobiographical self”, the patient's SA remained fundamentally intact. His Core SA, including basic self-recognition and sense of self-agency, was preserved. His Extended SA and Introspective SA were also largely intact, as he has a stable self-concept and intact higher-order metacognitive abilities. The results suggest that the insular cortex, ACC and mPFC are not required for most aspects of SA. Our findings are compatible with the hypothesis that SA is likely to emerge from more distributed interactions among brain networks including those in the brainstem, thalamus, and posteromedial cortices. PMID:22927899

  13. Folic acid and sulfasalazine for colorectal carcinoma chemoprevention in patients with ulcerative colitis: the old and new evidence.

    PubMed

    Diculescu, Mircea; Ciocîrlan, Mihai; Ciocîrlan, Mirela; Piţigoi, Dan; Becheanu, Gabriel; Croitoru, Adina; Spanache, Sandu

    2003-12-01

    The purpose of the study was to assess whether folic acid supplementation and long term therapy with sulfasalazine can reduce the risk of colorectal cancer (CRC) development in longstanding extensive ulcerative colitis. A meta-analysis was performed including the last 10 years published and Medline indexed studies on this subject. 3 studies have been included concerning the protective effect of folate supplementation in development of CRC. The association of these two factors is significant (effect size r =0.124, p = 0.025). The fail-safe number of studies with an opposite result should be 4 to revert the significance. 4 studies regarding sulfasalazine's protective effect in longstanding extensive ulcerative colitis have also been evaluated. A similar significance has been obtained, r = 0.148, p = 0.0007 and a fail-safe number of studies equal to 7. The homogeneity of these studies is validated by standard tests. Both sulfasalazine therapy and folate supplementation have a protective effect in colorectal cancer development in a population of patients with longstanding ulcerative colitis. Randomized controlled trials are needed to explore these hypotheses.

  14. Flat-plate solar array project. Volume 6: Engineering sciences and reliability

    NASA Technical Reports Server (NTRS)

    Ross, R. G., Jr.; Smokler, M. I.

    1986-01-01

    The Flat-Plate Solar Array (FSA) Project activities directed at developing the engineering technology base required to achieve modules that meet the functional, safety, and reliability requirements of large scale terrestrial photovoltaic systems applications are reported. These activities included: (1) development of functional, safety, and reliability requirements for such applications; (2) development of the engineering analytical approaches, test techniques, and design solutions required to meet the requirements; (3) synthesis and procurement of candidate designs for test and evaluation; and (4) performance of extensive testing, evaluation, and failure analysis of define design shortfalls and, thus, areas requiring additional research and development. A summary of the approach and technical outcome of these activities are provided along with a complete bibliography of the published documentation covering the detailed accomplishments and technologies developed.

  15. In vitro genotoxicity testing strategy for nanomaterials and the adaptation of current OECD guidelines

    PubMed Central

    Doak, S.H.; Manshian, B.; Jenkins, G.J.S.; Singh, N.

    2012-01-01

    There is a pressing requirement to define a hazard identification and risk management strategy for nanomaterials due to the rapid growth in the nanotechnology industry and their promise of life-style revolutions through the development of wide-ranging nano-containing consumer products. Consequently, a battery of well defined and appropriate in vitro assays to assess a number of genotoxicity endpoints is required to minimise extensive and costly in vivo testing. However, the validity of the established protocols in current OECD recognised genotoxicity assays for nanomaterials is currently being questioned. In this report, we therefore consider the in vitro OECD genotoxicity test battery including the Ames, micronucleus and HPRT forward mutation assays, and their potential role in the safety assessment of nanomaterial induced DNA damage in vitro. PMID:21971291

  16. LIVVkit: An extensible, python-based, land ice verification and validation toolkit for ice sheet models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kennedy, Joseph H.; Bennett, Andrew R.; Evans, Katherine J.

    To address the pressing need to better understand the behavior and complex interaction of ice sheets within the global Earth system, significant development of continental-scale, dynamical ice sheet models is underway. Concurrent to the development of the Community Ice Sheet Model (CISM), the corresponding verification and validation (V&V) process is being coordinated through a new, robust, Python-based extensible software package, the Land Ice Verification and Validation toolkit (LIVVkit). Incorporated into the typical ice sheet model development cycle, it provides robust and automated numerical verification, software verification, performance validation, and physical validation analyses on a variety of platforms, from personal laptopsmore » to the largest supercomputers. LIVVkit operates on sets of regression test and reference data sets, and provides comparisons for a suite of community prioritized tests, including configuration and parameter variations, bit-for-bit evaluation, and plots of model variables to indicate where differences occur. LIVVkit also provides an easily extensible framework to incorporate and analyze results of new intercomparison projects, new observation data, and new computing platforms. LIVVkit is designed for quick adaptation to additional ice sheet models via abstraction of model specific code, functions, and configurations into an ice sheet model description bundle outside the main LIVVkit structure. Furthermore, through shareable and accessible analysis output, LIVVkit is intended to help developers build confidence in their models and enhance the credibility of ice sheet models overall.« less

  17. LIVVkit: An extensible, python-based, land ice verification and validation toolkit for ice sheet models

    DOE PAGES

    Kennedy, Joseph H.; Bennett, Andrew R.; Evans, Katherine J.; ...

    2017-03-23

    To address the pressing need to better understand the behavior and complex interaction of ice sheets within the global Earth system, significant development of continental-scale, dynamical ice sheet models is underway. Concurrent to the development of the Community Ice Sheet Model (CISM), the corresponding verification and validation (V&V) process is being coordinated through a new, robust, Python-based extensible software package, the Land Ice Verification and Validation toolkit (LIVVkit). Incorporated into the typical ice sheet model development cycle, it provides robust and automated numerical verification, software verification, performance validation, and physical validation analyses on a variety of platforms, from personal laptopsmore » to the largest supercomputers. LIVVkit operates on sets of regression test and reference data sets, and provides comparisons for a suite of community prioritized tests, including configuration and parameter variations, bit-for-bit evaluation, and plots of model variables to indicate where differences occur. LIVVkit also provides an easily extensible framework to incorporate and analyze results of new intercomparison projects, new observation data, and new computing platforms. LIVVkit is designed for quick adaptation to additional ice sheet models via abstraction of model specific code, functions, and configurations into an ice sheet model description bundle outside the main LIVVkit structure. Furthermore, through shareable and accessible analysis output, LIVVkit is intended to help developers build confidence in their models and enhance the credibility of ice sheet models overall.« less

  18. Methods of extending signatures and training without ground information. [data processing, pattern recognition

    NASA Technical Reports Server (NTRS)

    Henderson, R. G.; Thomas, G. S.; Nalepka, R. F.

    1975-01-01

    Methods of performing signature extension, using LANDSAT-1 data, are explored. The emphasis is on improving the performance and cost-effectiveness of large area wheat surveys. Two methods were developed: ASC, and MASC. Two methods, Ratio, and RADIFF, previously used with aircraft data were adapted to and tested on LANDSAT-1 data. An investigation into the sources and nature of between scene data variations was included. Initial investigations into the selection of training fields without in situ ground truth were undertaken.

  19. Restoring a smooth function from its noisy integrals

    NASA Astrophysics Data System (ADS)

    Goulko, Olga; Prokof'ev, Nikolay; Svistunov, Boris

    2018-05-01

    Numerical (and experimental) data analysis often requires the restoration of a smooth function from a set of sampled integrals over finite bins. We present the bin hierarchy method that efficiently computes the maximally smooth function from the sampled integrals using essentially all the information contained in the data. We perform extensive tests with different classes of functions and levels of data quality, including Monte Carlo data suffering from a severe sign problem and physical data for the Green's function of the Fröhlich polaron.

  20. Airdata Measurement and Calibration

    NASA Technical Reports Server (NTRS)

    Haering, Edward A., Jr.

    1995-01-01

    This memorandum provides a brief introduction to airdata measurement and calibration. Readers will learn about typical test objectives, quantities to measure, and flight maneuvers and operations for calibration. The memorandum informs readers about tower-flyby, trailing cone, pacer, radar-tracking, and dynamic airdata calibration maneuvers. Readers will also begin to understand how some data analysis considerations and special airdata cases, including high-angle-of-attack flight, high-speed flight, and nonobtrusive sensors are handled. This memorandum is not intended to be all inclusive; this paper contains extensive reference and bibliography sections.

  1. Extending the Range of a BEV - Early Progress

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, John; Agathocleous, Nicos; Kang, SH

    The 2015 BEV Kia Soul is available with either a Positive Temperature Coefficient (PTC) heater only or an air-source R134a heat pump with PTC heater combination. Hanon, HATCI, and NREL are jointly, with financial support from the DoE, working towards extending the driving range of the heat pump vehicle. This presentation will focus on the early findings of the project, including test data of the baseline vehicle, early data from a modified vehicle, and range extension goals of the project.

  2. Lessons learned from the SLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phinney, N.

    The SLAC Linear Collider (SLC) is the first example of an entirely new type of lepton collider. Many years of effort were required to develop the understanding and techniques needed to approach design luminosity. This paper discusses some of the key issues and problems encountered in producing a working linear collider. These include the polarized source, techniques for emittance preservation, extensive feedback systems, and refinements in beam optimization in the final focus. The SLC experience has been invaluable for testing concepts and developing designs for a future linear collider.

  3. A decade of aeroacoustic research at NASA Ames Research Center

    NASA Technical Reports Server (NTRS)

    Schmitz, Frederic H.; Mosher, M.; Kitaplioglu, Cahit; Cross, J.; Chang, I.

    1988-01-01

    The rotorcraft aeroacoustic research accomplishments of the past decade at Ames Research Center are reviewed. These include an extensive sequence of flight, ground, and wind tunnel tests that have utilized the facilities to guide and pioneer theoretical research. Many of these experiments were of benchmark quality. The experiments were used to isolate the inadequacies of linear theory in high-speed impulsive noise research, have led to the development of theoretical approaches, and have guided the emerging discipline of computational fluid dynamics to rotorcraft aeroacoustic problems.

  4. Environmental sciences information storage and retrieval system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engstrom, D.E.; White, M.G.; Dunaway, P.B.

    Reynolds Electrical and Engineering Co., Inc. (REECo), has since 1970 accumulated information relating to the AEC's Nevada Applied Ecology Group (NAEG) programs at the Nevada Test Site (NTS). These programs, involving extensive soil, vegetation, and small-animal studies, have generated informational data concerning the collecting, processing, analyzing, and shipping of sample materials to various program participants and contractors. Future plans include incorporation of Lawrence Livermore Laboratory's resuspension study data, REECo's on-site air data, and EPA's large-animal, off-site air, and off-site soil data. (auth)

  5. Lifetime Alcoholics Anonymous attendance as a predictor of spiritual gains in the Relapse Replication and Extension Project (RREP).

    PubMed

    Tonigan, J Scott; McCallion, Elizabeth A; Frohe, Tessa; Pearson, Matthew R

    2017-02-01

    This study investigated the association between extent of lifetime attendance in Alcoholics Anonymous (AA) and spiritual gains among treatment seeking adults for alcohol use disorder. Participants included 246 individuals from 2 of the 3 sites in the Relapse Replication and Extension Project (Lowman, Allen, Stout, & The Relapse Research Group, 1996). Baseline characteristics included 63% male, 39.9% single, and the average age was 34 years (SD = 8.2). The Alcoholics Anonymous Involvement questionnaire (Tonigan, Connors, & Miller, 1996) was used to assess lifetime AA attendance. The Religious Beliefs & Behaviors Questionnaire (Connors, Tonigan, & Miller, 1996) was used to assess spirituality. Percent days abstinent (PDA) and drinks per drinking day (DPDD) were measured using the Form 90. At baseline, adults with more extensive AA histories were more severely alcohol impaired although they were no older relative to adults with less past AA exposure. Clear patterns of AA engagement were found between the high-low AA history groups over follow-up, with adults with less AA experience reporting less AA participation across a swath of AA-specific measures. Gains in spiritual practices significantly mediated AA-related benefit as measured by PDA and DPDD. Tests for moderated-mediation indicated that the magnitude of the mediational effect of spiritual gains did not differ between high-low AA history groups. Having an extensive AA history did not advantage (or disadvantage) adults in mobilizing future spiritual practices that are prescribed in AA. Clinical assessment of client AA history is important, however, because it predicts both the nature and extent that clients may participate in AA. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  6. The Role of Extensive Reading in the Development of Phonological Processing

    ERIC Educational Resources Information Center

    Nisanci, Sinan

    2017-01-01

    The present study aims to investigate the role of extensive reading in the acquisition of implicit phonological knowledge. Through extensive exposure to print, L2 learners can improve their phonological processing skills, and this could contribute to their word recognition fluency. On the basis of the Oxford Placement Test, 30 9th graders and 30…

  7. Measurement properties of the upright motor control test for adults with stroke: a systematic review.

    PubMed

    Gorgon, Edward James R; Lazaro, Rolando T

    2016-01-01

    The Upright Motor Control Test (UMCT) has been used in clinical practice and research to assess functional strength of the hemiparetic lower limb in adults with stroke. It is unclear if evidence is sufficient to warrant its use. The purpose of this systematic review was to synthesize available evidence on the measurement properties of the UMCT for stroke rehabilitation. Electronic databases that indexed biomedical literature were systematically searched from inception until October 2015 (week 4): Embase, PubMed, Web of Science, CINAHL, PEDro, Cochrane Library, Scopus, ScienceDirect, SPORTDiscus, LILACS, DOAJ, and Google Scholar. All studies that had used the UMCT in the time period covered underwent hand searching for any additional study. Observational studies involving adults with stroke that explored any measurement property of the UMCT were included. The COnsensus-based Standards for the selection of health Measurement INstruments was used to assess the methodological quality of included studies. The CanChild Outcome Measures Rating Form was used for extracting data on measurement properties and clinical utility. The search yielded three methodologic studies that addressed criterion-related validity and contruct validity. Two studies of fair methodological quality demonstrated moderate-level evidence that Knee Extension and Knee Flexion subtest scores were predictive of community-level and household-level ambulation. One study of fair methodological quality provided limited-level evidence for the correlation of Knee Extension subtest scores with a laboratory measure of ground reaction forces. No published studies formally assessed reliability, responsiveness, or clinical utility. Limited information on responsiveness and clinical utility dimensions could be inferred from the included studies. The UMCT is a practical assessment tool for voluntary control or functional strength of the hemiparetic lower limb in standing in adults with stroke. Although different levels of evidence suggest that the Knee Extension and Knee Flexion subtests may possess criterion and construct validity, the lack of published literature examining content validity, reliability, and responsiveness raises questions regarding the use of the UMCT in routine clinical practice. These key findings highlight the need to further investigate the UMCT's measurement properties toward enhancing its standardization.

  8. NASA Hydrogen Peroxide Propellant Hazards Technical Manual

    NASA Technical Reports Server (NTRS)

    Baker, David L.; Greene, Ben; Frazier, Wayne

    2005-01-01

    The Fire, Explosion, Compatibility and Safety Hazards of Hydrogen Peroxide NASA technical manual was developed at the NASA Johnson Space Center White Sands Test Facility. NASA Technical Memorandum TM-2004-213151 covers topics concerning high concentration hydrogen peroxide including fire and explosion hazards, material and fluid reactivity, materials selection information, personnel and environmental hazards, physical and chemical properties, analytical spectroscopy, specifications, analytical methods, and material compatibility data. A summary of hydrogen peroxide-related accidents, incidents, dose calls, mishaps and lessons learned is included. The manual draws from art extensive literature base and includes recent applicable regulatory compliance documentation. The manual may be obtained by United States government agencies from NASA Johnson Space Center and used as a reference source for hazards and safe handling of hydrogen peroxide.

  9. Solid Propulsion Systems, Subsystems, and Components Service Life Extension

    NASA Technical Reports Server (NTRS)

    Hundley, Nedra H.; Jones, Connor

    2011-01-01

    The service life extension of solid propulsion systems, subsystems, and components will be discussed based on the service life extension of the Space Transportation System Reusable Solid Rocket Motor (RSRM) and Booster Separation Motors (BSM). The RSRM is certified for an age life of five years. In the aftermath of the Columbia accident there were a number of motors that were approaching the end of their five year service life certification. The RSRM Project initiated an assessment to determine if the service life of these motors could be extended. With the advent of the Constellation Program, a flight test was proposed that would utilize one of the RSRMs which had been returned from the launch site due to the expiration of its five year service life certification and twelve surplus Chemical Systems Division BSMs which had exceeded their eight year service life. The RSRM age life tracking philosophy which establishes when the clock starts for age life tracking will be described. The role of the following activities in service life extension will be discussed: subscale testing, accelerated aging, dissecting full scale aged hardware, static testing full scale aged motors, data mining industry data, and using the fleet leader approach. The service life certification and extension of the BSMs will also be presented.

  10. Piezoelectric pushers for active vibration control of rotating machinery

    NASA Technical Reports Server (NTRS)

    Palazzolo, A. B.; Kascak, A. F.; Lin, R. R.; Montague, J.; Alexander, R. M.

    1989-01-01

    The active control of rotordynamic vibrations and stability by magnetic bearings and electromagnetic shakers was discussed extensively in the literature. These devices, though effective, are usually large in volume and add significant weight to the stator. The use of piezoelectric pushers may provide similar degrees of effectiveness in light, compact packages. Analyses are contained which extend quadratic regulator, pole placement and derivative feedback control methods to the prescribed displacement character of piezoelectric pushers. The structural stiffness of the pusher is also included in the theory. Tests are currently being conducted at NASA Lewis Research Center with piezoelectric pusher-based active vibration control. Results performed on the NASA test rig as preliminary verification of the related theory are presented.

  11. X-33 Integrated Test Facility Extended Range Simulation

    NASA Technical Reports Server (NTRS)

    Sharma, Ashley

    1998-01-01

    In support of the X-33 single-stage-to-orbit program, NASA Dryden Flight Research Center was selected to provide continuous range communications of the X-33 vehicle from launch at Edwards Air Force Base, California, through landing at Malmstrom Air Force Base Montana, or at Michael Army Air Field, Utah. An extensive real-time range simulation capability is being developed to ensure successful communications with the autonomous X-33 vehicle. This paper provides an overview of various levels of simulation, integration, and test being developed to support the X-33 extended range subsystems. These subsystems include the flight termination system, L-band command uplink subsystem, and S-band telemetry downlink subsystem.

  12. Evaluation of unsaturated-zone solute-transport models for studies of agricultural chemicals

    USGS Publications Warehouse

    Nolan, Bernard T.; Bayless, E. Randall; Green, Christopher T.; Garg, Sheena; Voss, Frank D.; Lampe, David C.; Barbash, Jack E.; Capel, Paul D.; Bekins, Barbara A.

    2005-01-01

    Of the models tested, RZWQM, HYDRUS2D, VS2DT, GLEAMS and PRZM had graphical user interfaces. Extensive documentation was available for RZWQM, HYDRUS2D, and VS2DT. RZWQM can explicitly simulate water and solute flux in macropores, and both HYDRUS2D and VS2DT can simulate water and solute flux in two dimensions. The version of RZWQM tested had a maximum simulation depth of 3 meters. The complex models simulate the formation, transport, and fate of degradates of up to three to five compounds including the parent, with the exception of VS2DT, which simulates the transport and fate of a single compound.

  13. A new method of real-time detection of changes in periodic data stream

    NASA Astrophysics Data System (ADS)

    Lyu, Chen; Lu, Guoliang; Cheng, Bin; Zheng, Xiangwei

    2017-07-01

    The change point detection in periodic time series is much desirable in many practical usages. We present a novel algorithm for this task, which includes two phases: 1) anomaly measure- on the basis of a typical regression model, we propose a new computation method to measure anomalies in time series which does not require any reference data from other measurement(s); 2) change detection- we introduce a new martingale test for detection which can be operated in an unsupervised and nonparametric way. We have conducted extensive experiments to systematically test our algorithm. The results make us believe that our algorithm can be directly applicable in many real-world change-point-detection applications.

  14. Preliminary flight test results of a fly-by-throttle emergency flight control system on an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Burcham, Frank W., Jr.; Maine, Trindel A.; Fullerton, C. G.; Wells, Edward A.

    1993-01-01

    A multi-engine aircraft, with some or all of the flight control system inoperative, may use engine thrust for control. NASA Dryden has conducted a study of the capability and techniques for this emergency flight control method for the F-15 airplane. With an augmented control system, engine thrust, along with appropriate feedback parameters, is used to control flightpath and bank angle. Extensive simulation studies have been followed by flight tests. This paper discusses the principles of throttles-only control, the F-15 airplane, the augmented system, and the flight results including landing approaches with throttles-only control to within 10 ft of the ground.

  15. Comparing On-Orbit and Ground Performance for an S-Band Software-Defined Radio

    NASA Technical Reports Server (NTRS)

    Chelmins, David T.; Welch, Bryan W.

    2014-01-01

    NASA's Space Communications and Navigation Testbed was installed on an external truss of the International Space Station in 2012. The testbed contains several software-defined radios (SDRs), including the Jet Propulsion Laboratory (JPL) SDR, which underwent performance testing throughout 2013 with NASAs Tracking and Data Relay Satellite System (TDRSS). On-orbit testing of the JPL SDR was conducted at S-band with the Glenn Goddard TDRSS waveform and compared against an extensive dataset collected on the ground prior to launch. This paper will focus on the development of a waveform power estimator on the ground post-launch and discuss the performance challenges associated with operating the power estimator in space.

  16. Comparing On-Orbit and Ground Performance for an S-Band Software-Defined Radio

    NASA Technical Reports Server (NTRS)

    Chelmins, David; Welch, Bryan

    2014-01-01

    NASA's Space Communications and Navigation Testbed was installed on an external truss of the International Space Station in 2012. The testbed contains several software-defined radios (SDRs), including the Jet Propulsion Laboratory (JPL) SDR, which underwent performance testing throughout 2013 with NASA's Tracking and Data Relay Satellite System (TDRSS). On-orbit testing of the JPL SDR was conducted at S-band with the Glenn Goddard TDRSS waveform and compared against an extensive dataset collected on the ground prior to launch. This paper will focus on the development of a waveform power estimator on the ground post-launch and discuss the performance challenges associated with operating the power estimator in space.

  17. Selected advanced aerodynamics and active controls technology concepts development on a derivative B-747

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The feasibility of applying wing tip extensions, winglets, and active control wing load alleviation to the Boeing 747 is investigated. Winglet aerodynamic design methods and high speed wind tunnel test results of winglets and of symmetrically deflected ailerons are presented. Structural resizing analyses to determine weight and aeroelastic twist increments for all the concepts and flutter model test results for the wing with winglets are included. Control law development, system mechanization/reliability studies, and aileron balance tab trade studies for active wing load alleviation systems are discussed. Results are presented in the form of incremental effects on L/D, structural weight, block fuel savings, stability and control, airplane price, and airline operating economics.

  18. Airborne surveys of USA urban areas at 121.5/243 MHz

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.; Hill, J. S.

    1979-01-01

    In situ, aircraft flight measurements were made in 1976 and 1977 by NASA of the radio-frequency environment over USA urban areas within the emergency distress search and rescue frequency bands at 121.5 and 243.0 MHz. This paper analyzes test results reported previously for USA East Coast and Midwest flight surveys; presented also are test results obtained in May 1977 for the USA West Coast during the NASA, ASSESS-II, Space Shuttle/Spacelab simulation aircraft flights. The USA West Coast flight include data at 121.5/243 MHz during an extensive series of aircraft passes for the Los Angeles urban area. The USA East Coast/Midwest measurements show correlation with population count.

  19. Inhibition of human papillomavirus expression using DNAzymes.

    PubMed

    Benítez-Hess, María Luisa; Reyes-Gutiérrez, Pablo; Alvarez-Salas, Luis Marat

    2011-01-01

    Deoxyribozymes (DXZs) are catalytic oligodeoxynucleotides capable of performing diverse functions including the specific cleavage of a target RNA. These molecules represent a new type of therapeutic oligonucleotides combining the efficiency of ribozymes and the intracellular endurance and simplicity of modified antisense oligonucleotides. Commonly used DXZs include the 8-17 and 10-23 motifs, which have been engineered to destroy disease-associated genes with remarkable efficiency. Targeting DXZs to disease-associated transcripts requires extensive biochemical testing to establish target RNA accessibility, catalytic efficiency, and nuclease sensibility. The usage of modified nucleotides to render nuclease-resistance DXZs must be counterweighted against deleterious consequences on catalytic activity. Further intracellular testing is required to establish the effect of microenvironmental conditions on DXZ activity and off-target issues. Application of modified DXZs to cervical cancer results in specific growth inhibition, cell death, and apoptosis. Thus, DXZs represent a highly effective antisense moiety with minimal secondary effects.

  20. New-type steel plate with ultra high crack-arrestability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishikawa, T.; Nomiyama, Y.; Hagiwara, Y.

    1995-12-31

    A new-type steel plate has been developed by controlling the microstructure of the surface layers. The surface layer consists of ultra fine grain ferrite microstructure, which provides excellent fracture toughness even at cryogenic temperature. When an unstable brittle crack propagates in the developed steel plate, shear-lips can be easily formed due to the surface layers with ultra fine grain microstructure. Since unstable running crack behavior is strongly affected by side-ligaments (shear-lips), which are associated with extensive plastic deformation, enhanced formation of the shear-lips can improve crack arrestability. This paper describes the developed steel plates of HT500MPa tensile strength class formore » shipbuilding use. Fracture mechanics investigations using large-scale fracture testings (including ultrawide duplex ESSO tests) clarified that the developed steel plates have ultra high crack-arrestability. It was also confirmed that the plates possess sufficient properties, including weldability and workability, for ship building use.« less

Top