Sample records for extensor tendon repair

  1. Endoscopic-assisted Repair of Neglected Rupture or Rerupture After Primary Repair of Extensor Hallucis Longus Tendon.

    PubMed

    Lui, Tun Hing; Chang, Joseph Jeremy; Maffulli, Nicola

    2016-03-01

    Rerupture of the extensor hallucis longus tendon after primary repair and neglected rupture of the tendon poses surgical challenges to orthopedic surgeons. Open exploration and repair of the tendon ends usually requires large incision and extensive dissection. This may induce scarring and adhesion around the repaired tendon. Endoscopic-assisted repair has the advantage of minimally invasive surgery including less soft tissue trauma and scar formation and better cosmetic result. The use of Krackow locking suture and preservation of the extensor retinacula allow early mobilization of the great toe.

  2. Extensor Tendon Injuries and Repairs in the Hand

    PubMed Central

    Kontor, J. A.

    1982-01-01

    Due to their superficial course, the extensor tendons are frequently lacerated over the dorsum of the hand and fingers. Excellent functional results are obtained in repairs of simple tendon lacerations. ‘Open’ mallet lacerations over the distal IP joint or involving the central extensor slip over the proximal IP joint require more precise suturing methods. More proximal extensor tendon divisions near the wrist involve dissection of the retracted finger extensors or long thumb extensor in the distal forearm and more formal tendon repairs, including a possible tendon transfer to the thumb. ‘Closed injuries’, with varying degrees of extensor tendon disruption, occur at three main sites. The mallet injury at the DIP joint and the boutonnière deformity over the PIP joint are sometimes recognized late, but respond to conservative splinting for a minimum of four weeks with guarded motion avoiding secondary stiffening of the remaining small joints of the hand. Surgery of closed injuries most frequently involves the intra-articular traction fracture type of mallet deformities in which the DIP joint has taken the brunt of the injury. PMID:21286174

  3. Optimal early active mobilisation protocol after extensor tendon repairs in zones V and VI: A systematic review of literature.

    PubMed

    Collocott, Shirley Jf; Kelly, Edel; Ellis, Richard F

    2018-03-01

    Early mobilisation protocols after repair of extensor tendons in zone V and VI provide better outcomes than immobilisation protocols. This systematic review investigated different early active mobilisation protocols used after extensor tendon repair in zone V and VI. The purpose was to determine whether any one early active mobilisation protocol provides superior results. An extensive literature search was conducted to identify articles investigating the outcomes of early active mobilisation protocols after extensor tendon repair in zone V and VI. Databases searched were AMED, Embase, Medline, Cochrane and CINAHL. Studies were included if they involved participants with extensor tendon repairs in zone V and VI in digits 2-5 and described a post-operative rehabilitation protocol which allowed early active metacarpophalangeal joint extension. Study designs included were randomised controlled trials, observational studies, cohort studies and case series. The Structured Effectiveness Quality Evaluation Scale was used to evaluate the methodological quality of the included studies. Twelve articles met the inclusion criteria. Two types of early active mobilisation protocols were identified: controlled active motion protocols and relative motion extension splinting protocols. Articles describing relative motion extension splinting protocols were more recent but of lower methodological quality than those describing controlled active motion protocols. Participants treated with controlled active motion and relative motion extension splinting protocols had similar range of motion outcomes, but those in relative motion extension splinting groups returned to work earlier. The evidence reviewed suggested that relative motion extension splinting protocols may allow an earlier return to function than controlled active motion protocols without a greater risk of complication.

  4. Rehabilitation of flexor and extensor tendon injuries in the hand: current updates.

    PubMed

    Howell, Julianne W; Peck, Fiona

    2013-03-01

    In recent years, a significant amount of research in the field of tendon injury in the hand has contributed to advances in both surgical and rehabilitation techniques. The introduction of early motion has improved tendon healing, reduced complications, and enhanced final outcomes. There is overwhelming evidence to show that carefully devised rehabilitation programs are critical to achieving favourable outcomes. Whatever the type, or level, of flexor or extensor injury, the ultimate goal of both the surgeon and therapist is to protect the repair, modify peritendinous adhesions, promote optimal tendon excursion and preserve joint motion. Early tendon motion regimens are initiated at surgery or within 5 days post repair. Intra-operative information from the surgeon to the therapist is vital to the choice of splint protected position to reduce repair rupture/gap forces, and to commencement of active, or splint controlled, motion for tendon excursion. Decisions should align with the phases of healing, the clinician's observations, frequent range of motion measurements and patient input. Clinical concepts pertinent to early motion rehabilitation decisions are presented by zone of injury for both flexor and extensor tendons during the early phases of healing. Copyright © 2013. Published by Elsevier Ltd.

  5. Tendon injuries of the hand

    PubMed Central

    Schöffl, Volker; Heid, Andreas; Küpper, Thomas

    2012-01-01

    Tendon injuries are the second most common injuries of the hand and therefore an important topic in trauma and orthopedic patients. Most injuries are open injuries to the flexor or extensor tendons, but less frequent injuries, e.g., damage to the functional system tendon sheath and pulley or dull avulsions, also need to be considered. After clinical examination, ultrasound and magnetic resonance imaging have proved to be important diagnostic tools. Tendon injuries mostly require surgical repair, dull avulsions of the distal phalanges extensor tendon can receive conservative therapy. Injuries of the flexor tendon sheath or single pulley injuries are treated conservatively and multiple pulley injuries receive surgical repair. In the postoperative course of flexor tendon injuries, the principle of early passive movement is important to trigger an “intrinsic” tendon healing to guarantee a good outcome. Many substances were evaluated to see if they improved tendon healing; however, little evidence was found. Nevertheless, hyaluronic acid may improve intrinsic tendon healing. PMID:22720265

  6. Extensor tendon injury during cesarean delivery.

    PubMed

    Rinker, Brian

    2011-01-01

    Fetal laceration is a recognized complication of cesarean delivery; however, major injuries are rare. The case of a healthy newborn who sustained an injury to the extensor pollicis longus tendon during cesarean delivery is reported. The tendon was repaired surgically on the sixth day of life with good recovery of function. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  7. Fresh-frozen Complete Extensor Mechanism Allograft versus Autograft Reconstruction in Rabbits

    PubMed Central

    Chen, Guanyin; Zhang, Hongtao; Ma, Qiong; Zhao, Jian; Zhang, Yinglong; Fan, Qingyu; Ma, Baoan

    2016-01-01

    Different clinical results have been reported in the repair of extensor mechanism disruption using fresh-frozen complete extensor mechanism (CEM) allograft, creating a need for a better understanding of fresh-frozen CME allograft reconstruction. Here, we perform histological and biomechanical analyses of fresh-frozen CEM allograft or autograft reconstruction in an in vivo rabbit model. Our histological results show complete incorporation of the quadriceps tendon into the host tissues, patellar survival and total integration of the allograft tibia, with relatively fewer osteocytes, into the host tibia. Vascularity and cellularity are reduced and delayed in the allograft but exhibit similar distributions to those in the autograft. The infrapatellar fat pad provides the main blood supply, and the lowest cellularity is observed in the patellar tendon close to the tibia in both the allograft and autograft. The biomechanical properties of the junction of quadriceps tendon and host tissues and those of the allograft patellar tendon are completely and considerably restored, respectively. Therefore, fresh-frozen CEM allograft reconstruction is viable, but the distal patellar tendon and the tibial block may be the weak links of the reconstruction. These findings provide new insight into the use of allograft in repairing disruption of the extensor mechanism. PMID:26911538

  8. Fresh-frozen Complete Extensor Mechanism Allograft versus Autograft Reconstruction in Rabbits.

    PubMed

    Chen, Guanyin; Zhang, Hongtao; Ma, Qiong; Zhao, Jian; Zhang, Yinglong; Fan, Qingyu; Ma, Baoan

    2016-02-25

    Different clinical results have been reported in the repair of extensor mechanism disruption using fresh-frozen complete extensor mechanism (CEM) allograft, creating a need for a better understanding of fresh-frozen CME allograft reconstruction. Here, we perform histological and biomechanical analyses of fresh-frozen CEM allograft or autograft reconstruction in an in vivo rabbit model. Our histological results show complete incorporation of the quadriceps tendon into the host tissues, patellar survival and total integration of the allograft tibia, with relatively fewer osteocytes, into the host tibia. Vascularity and cellularity are reduced and delayed in the allograft but exhibit similar distributions to those in the autograft. The infrapatellar fat pad provides the main blood supply, and the lowest cellularity is observed in the patellar tendon close to the tibia in both the allograft and autograft. The biomechanical properties of the junction of quadriceps tendon and host tissues and those of the allograft patellar tendon are completely and considerably restored, respectively. Therefore, fresh-frozen CEM allograft reconstruction is viable, but the distal patellar tendon and the tibial block may be the weak links of the reconstruction. These findings provide new insight into the use of allograft in repairing disruption of the extensor mechanism.

  9. Extensor Mechanism Disruption after Total Knee Arthroplasty: A Case Series and Review of Literature.

    PubMed

    Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul

    2016-02-04

    Extensor mechanism disruption following total knee arthroplasty (TKA) is a rare but devastating complication. These patients may require revision of the implants, but even then, it may not be possible to restore the normal function of the knee after the disruption. The patterns of extensor mechanism disruption can broadly be classified into three types: suprapatellar (quadriceps tendon rupture), transpatellar (patellar fracture), or infrapatellar (patellar tendon rupture). Infrapatellar tendon ruptures are the worst injuries, as they carry maximum morbidity and are challenging to manage. The disruption of the extensor mechanism may occur either intra-operatively or in the immediate postoperative period due to an injury. The treatment of extensor mechanism complications after TKA may include either nonsurgical management or surgical intervention in the form of primary repair or reconstruction with autogenous, allogeneic, or synthetic substitutes. We have provided an algorithm for the management of extensor mechanism disruption after TKA.

  10. Suture anchor repair of patellar tendon rupture after total knee arthroplasty.

    PubMed

    Kamath, Atul F; Shah, Roshan P; Summers, Nathan; Israelite, Craig L

    2013-12-01

    Extensor mechanism disruption after total knee arthroplasty (TKA) is a complex problem that often requires surgical repair for functional deficits. We present a brief technical note on suture anchor fixation of a patellar tendon rupture after TKA. A surgical technique and literature review follows. Although suture anchor fixation is well described for tendinous repairs in other areas of orthopedic surgery, no study has discussed the use of suture anchors in patellar tendon repair after TKA. The technique must be evaluated in more patients with longer follow-up before adoption. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Suture anchor repair of quadriceps tendon rupture after total knee arthroplasty.

    PubMed

    Kim, Tae Won B; Kamath, Atul F; Israelite, Craig L

    2011-08-01

    Disruption of the extensor mechanism after total knee arthroplasty (TKA) is a devastating complication, usually requiring surgical repair. Although suture anchor fixation is well described for repair of the ruptured native knee quadriceps tendon, no study has discussed the use of suture anchors in quadriceps repair after TKA. We present an illustrative case of successful suture anchor fixation of the quadriceps mechanism after TKA. The procedure has been performed in a total of 3 patients. A surgical technique and brief review of the literature follows. Suture anchor fixation of the quadriceps tendon is a viable option in the setting of rupture after TKA. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Treatment of chronic extensor tendons lesions of the fingers.

    PubMed

    Bellemère, P

    2015-09-01

    Chronic finger extensor apparatus injuries are the result of the initial acute treatment having failed or being flawed. Because of their chronic nature, these injuries present various amounts of tendon retraction, tendon callus lengthening, peritendinous scar adhesions, static and dynamic imbalances with the flexor apparatus and intrinsic muscles, and joint contractures. This article will review the anatomy of the extensor mechanism and then will outline by location, the various clinical pictures that are secondary to chronic tendon injury. The clinical presentation of these injuries can be highly variable but their symptomatology and treatment are very specific. Of the possible therapeutic strategies for chronic mallet finger with or without associated swan-neck deformity, chronic boutonniere deformity, chronic sagittal band injuries, old ruptures on the dorsum of the wrist and traumatic defects in multiple tissues, conservative treatment is often the main element. Secondary surgical repair is not free of complications, and the results are often lacking. Rehabilitation and orthotic bracing are an integral part of the management of these injuries, no matter which treatment method is being considered. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  13. Traumatic Extensor Tendon Injuries to the Hand: Clinical Anatomy, Biomechanics, and Surgical Procedure Review.

    PubMed

    Colzani, Giulia; Tos, Pierluigi; Battiston, Bruno; Merolla, Giovanni; Porcellini, Giuseppe; Artiaco, Stefano

    2016-04-01

    The extensor apparatus is a complex muscle-tendon system that requires integrity or optimal reconstruction to preserve hand function. Anatomical knowledge and the understanding of physiopathology of extensor tendons are essential for an accurate diagnosis of extensor tendon injuries (ETIs) of the hand and wrist, because these lesions are complex and commonly observed in clinical practice. A careful clinical history and assessment still remain the first step for the diagnosis, followed by US and MR to confirm the suspect of ETI or to investigate some doubtful conditions and rule out associate lesions. During last decades the evolution of surgical techniques and rehabilitative treatment protocol led to gradual improvement in clinical results of ETI treatment and surgical repair. Injury classification into anatomical zones and the evaluation of the characteristics of the lesions are considered key points to select the appropriate treatment for ETI. Both conservative and surgical management can be indicated in ETI, depending on the anatomical zone and on the characteristics of the injuries. As a general rule, an attempt of conservative treatment should be performed when the lesion is expected to have favorable result with nonoperative procedure. Many surgical techniques have been proposed over the time and with favorable results if the tendon injury is not underestimated and adequately treated. Despite recent research findings, a lack of evidence-based knowledge is still observed in surgical treatment and postoperative management of ETI. Further clinical and biomechanical investigations would be advisable to clarify this complex issue.

  14. Traumatic Extensor Tendon Injuries to the Hand: Clinical Anatomy, Biomechanics, and Surgical Procedure Review

    PubMed Central

    Colzani, Giulia; Tos, Pierluigi; Battiston, Bruno; Merolla, Giovanni; Porcellini, Giuseppe; Artiaco, Stefano

    2016-01-01

    The extensor apparatus is a complex muscle-tendon system that requires integrity or optimal reconstruction to preserve hand function. Anatomical knowledge and the understanding of physiopathology of extensor tendons are essential for an accurate diagnosis of extensor tendon injuries (ETIs) of the hand and wrist, because these lesions are complex and commonly observed in clinical practice. A careful clinical history and assessment still remain the first step for the diagnosis, followed by US and MR to confirm the suspect of ETI or to investigate some doubtful conditions and rule out associate lesions. During last decades the evolution of surgical techniques and rehabilitative treatment protocol led to gradual improvement in clinical results of ETI treatment and surgical repair. Injury classification into anatomical zones and the evaluation of the characteristics of the lesions are considered key points to select the appropriate treatment for ETI. Both conservative and surgical management can be indicated in ETI, depending on the anatomical zone and on the characteristics of the injuries. As a general rule, an attempt of conservative treatment should be performed when the lesion is expected to have favorable result with nonoperative procedure. Many surgical techniques have been proposed over the time and with favorable results if the tendon injury is not underestimated and adequately treated. Despite recent research findings, a lack of evidence-based knowledge is still observed in surgical treatment and postoperative management of ETI. Further clinical and biomechanical investigations would be advisable to clarify this complex issue. PMID:27616821

  15. Acute flexor tendon injury following midshaft radius and ulna fractures in a paediatric patient.

    PubMed

    Williams, James; Wharton, Rupert; Peev, Peter; Horwitz, Maxim

    2018-06-01

    Delayed rupture of the extensor and flexor tendons are recognised complications of distal radius fractures. However, acute flexor tendon rupture in the context of forearm fractures is rare. A twelve-year-old female sustained midshaft fractures of the radius and ulna. Intra-operatively the flexor pollicis longus (FPL) was found to be stripped from its musculotendinous junction at the level of the fracture fragment. The ruptured tendon was repaired using a modified Krackow technique at the time of fracture fixation. The repair was protected in plaster of Paris prior to referral to the paediatric hand clinic. The patient made a full recovery. Flexor tendon injury is a rare but potentially devastating consequence of acute forearm fractures. High energy trauma, significant volar angulation of the fracture fragment and clinical signs of flexor tendon injury should raise suspicion of this injury. A high index of suspicion in conjunction with repeat clinical examination of flexor tendon function should be performed before opting for closed management or intramedullary nailing in paediatric patients.

  16. Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability.

    PubMed

    Bruyn, George A W; Hanova, Petra; Iagnocco, Annamaria; d'Agostino, Maria-Antonietta; Möller, Ingrid; Terslev, Lene; Backhaus, Marina; Balint, Peter V; Filippucci, Emilio; Baudoin, Paul; van Vugt, Richard; Pineda, Carlos; Wakefield, Richard; Garrido, Jesus; Pecha, Ondrej; Naredo, Esperanza

    2014-11-01

    To develop the first ultrasound scoring system of tendon damage in rheumatoid arthritis (RA) and assess its intraobserver and interobserver reliability. We conducted a Delphi study on ultrasound-defined tendon damage and ultrasound scoring system of tendon damage in RA among 35 international rheumatologists with experience in musculoskeletal ultrasound. Twelve patients with RA were included and assessed twice by 12 rheumatologists-sonographers. Ultrasound examination for tendon damage in B mode of five wrist extensor compartments (extensor carpi radialis brevis and longus; extensor pollicis longus; extensor digitorum communis; extensor digiti minimi; extensor carpi ulnaris) and one ankle tendon (tibialis posterior) was performed blindly, independently and bilaterally in each patient. Intraobserver and interobserver reliability were calculated by κ coefficients. A three-grade semiquantitative scoring system was agreed for scoring tendon damage in B mode. The mean intraobserver reliability for tendon damage scoring was excellent (κ value 0.91). The mean interobserver reliability assessment showed good κ values (κ value 0.75). The most reliable were the extensor digiti minimi, the extensor carpi ulnaris, and the tibialis posterior tendons. An ultrasound reference image atlas of tenosynovitis and tendon damage was also developed. Ultrasound is a reproducible tool for evaluating tendon damage in RA. This study strongly supports a new reliable ultrasound scoring system for tendon damage. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Quadriceps tendon injuries in national football league players.

    PubMed

    Boublik, Martin; Schlegel, Theodore F; Koonce, Ryan C; Genuario, James W; Kinkartz, Jason D

    2013-08-01

    Distal quadriceps tendon tears are uncommon injuries that typically occur in patients older than 40 years of age, and they have a guarded prognosis. Predisposing factors, prodromal findings, mechanisms of injury, treatment guidelines, and recovery expectations are not well described in high-level athletes. Professional American football players with an isolated tear of the quadriceps tendon treated with timely surgical repair will return to their sport. Case series; Level of evidence, 4. Fourteen unilateral distal quadriceps tendon tears were identified in National Football League (NFL) players from 1994 to 2004. Team physicians retrospectively reviewed training room and clinic records, operative notes, and imaging studies for each of these players. Data on each player were analyzed to identify variables predicting return to play. A successful outcome was defined as returning to play in regular-season NFL games. Eccentric contraction of the quadriceps was the most common mechanism of injury, occurring in 10 players. Only 1 player had antecedent ipsilateral extensor mechanism symptoms. Eleven players had a complete rupture of the quadriceps tendon, and 3 had partial tears. There were no associated knee injuries. All ruptures were treated with surgical repair, 1 of which was delayed after failure of nonoperative treatment. Fifty percent of players returned to play in regular-season NFL games. There was a trend toward earlier draft status for those who returned to play compared with those who did not (draft round, 3.1 ± 2.5 vs. 6.0 ± 2.9, respectively; P = .073). For those who returned to play, the average number of games after injury was 40.9 (range, 12-92). Quadriceps tendon tears are rare in professional American football players, and they usually occur from eccentric load on the extensor mechanism. Prodromal symptoms and predisposing factors are usually absent. Even with timely surgical repair, there is a low rate of return to play in regular-season games. There is a trend toward early draft rounds for those who successfully return to play.

  18. Two case reports-Use of relative motion orthoses to manage extensor tendon zones III and IV and sagittal band injuries in adjacent fingers.

    PubMed

    Hirth, Melissa J; Howell, Julianne W; O'Brien, Lisa

    Case report. Injuries to adjacent fingers with differing extensor tendon (ET) zones and/or sagittal band pose a challenge to therapists as no treatment guidelines exist. This report highlights how the relative motion flexion/extension (RMF/RME) concepts were combined into one orthosis to manage a zone IV ET repair (RME) and a zone III central slip repair (RMF) in adjacent fingers (Case 1); and how a single RME orthosis was adapted to limit proximal interphalangeal joint motion to manage multi-level ET zone III-IV injuries and a sagittal band repair in adjacent fingers (case 2). Adapted relative motion orthoses allowed early active motion and graded exercises based on clinical reasoning and evidence. Outcomes were standard TAM% and Miller's criteria. 'Excellent' and 'good' outcomes were achieved by twelve weeks post surgery. Both cases returned to unrestricted work at 6 and 7 weeks. Neither reported functional deficits at discharge. Outcomes in 2 cases involving multiple digit injuries exceeded those previously reported for ET zone III-IV repairs. Relative motion orthoses can be adapted and applied to multi-finger injuries, eliminating the need for multiple, bulky or functionally-limiting orthoses. 4. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  19. Conservative treatment of an acute traumatic extensor carpi ulnaris tendon subluxation in a collegiate basketball player: a case report.

    PubMed

    Patterson, Steve M; Picconatto, William J; Alexander, Julie A; Johnson, Rachel L

    2011-01-01

    To present the case of an acute traumatic extensor carpi ulnaris (ECU) subluxation in a National Collegiate Athletic Association Division II female basketball player. The ECU tendon is stabilized in the ulnar groove by a subsheath located inferior to the extensor retinaculum. The subsheath can be injured with forced supination, ulnar deviation, and wrist flexion, resulting in the ECU tendon subluxing in the palmar and ulnar directions during wrist circumduction. Several methods of intervention exist, but controversy remains on how to best treat this condition. Distal ulnar fracture, ulnar collateral ligament sprain, triangular fibrocartilage complex lesion, lunotriquetral instability, distal radioulnar joint injury, pisotriquetral joint injury, ECU tendinopathy or subluxation. The wrist was placed in a short-arm cast in slight extension and radial deviation for 4 weeks. At that time, the patient was still able to actively sublux the ECU tendon, so a long-arm cast was applied with the wrist in slight extension, radial deviation, and pronation for an additional 4 weeks. The ECU tendon was then found to be stable. She wore a rigid wrist brace for 3 more weeks while she pursued rehabilitation. At the final follow-up appointment, the ECU tendon remained stable, and the wrist was asymptomatic. Subluxations of the ECU are rare. If the patient does not improve with conservative measures, surgical intervention is warranted to repair the sixth dorsal compartment. A long-arm cast with the elbow flexed to 90° and the wrist in approximately 30° of extension, radial deviation, and pronation was appropriate treatment for this type of injury.

  20. Tendon 'turnover lengthening' technique.

    PubMed

    Cerovac, S; Miranda, B H

    2013-11-01

    Tendon defect reconstruction is amongst the most technically challenging areas in hand surgery. Tendon substance deficiency reconstruction techniques include lengthening, grafting, two-stage reconstruction and tendon transfers, however each is associated with unique challenges over and above direct repair. We describe a novel 'turnover lengthening' technique for hand tendons that has successfully been applied to the repair of several cases, including a case of attritional flexor and traumatic extensor tendon rupture in two presented patients where primary tenorrhaphy was not possible. In both cases a good post-operative outcome was achieved, as the patients were happy having returned back to normal activities of daily living such that they were discharged 12 weeks post-operatively. Our technique avoids the additional morbidity and complications associated with grafting, transfers and two stage reconstructions. It is quick, simple and reproducible for defects not exceeding 3-4 cm, provides a means of immediate one stage reconstruction, no secondary donor site morbidity and does not compromise salvage by tendon transfer and/or two-stage reconstruction in cases of failure. To our knowledge no such technique has been previously been described to reconstruct such hand tendon defects. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  1. Effect of elbow and forearm position on contact pressure between the extensor origin and the lateral side of the capitellum.

    PubMed

    Tanaka, Yoshitaka; Aoki, Mitsuhiro; Izumi, Tomoki; Wada, Takuro; Fujimiya, Mineko; Yamashita, Toshihiko

    2011-01-01

    Bone-to-tendon contact in the origin of the common extensor tendons is considered to be one of the causes of lateral epicondylitis. Some factors, including elbow and forearm position, varus stress to the elbow, or contraction of the wrist extensor tendons, are considered to affect this bone-to-tendon contact. However, no studies have evaluated the effect of the elbow and forearm position on bone-tendon interface. The purpose of this study is to evaluate the effect of the position of the elbow and forearm on the contact pressure of the tendinous origin of the common wrist and finger extensors. We used 8 fresh cadaveric upper extremities. Contact pressure between the origin of the common extensor tendons and the lateral side of the capitellum was measured with a pressure sensor and was compared among various conditions, including elbow flexion angle (0°, 30°, 60°, and 90°), forearm rotation position (neutral and 81.5° pronation position), and varus stress load of the elbow (none, gravity on the forearm, and gravity on the forearm +1.96 Nm). Contact pressure was also measured during tension force of the extensor carpi radialis longus, extensor carpi radialis brevis, and extensor digitorum communis by 0, 9.8, and 19.6 N. Contact pressure was significantly increased with the elbow extension position, forearm pronation position, and varus stress to the elbow under tension of the extensor carpi radialis longus or extensor carpi radialis brevis. This study provides data about the amount of contact pressure between bone and tendon at the origin of the common extensor tendons in the elbow. This information may lead to a better understanding of, and better treatment for, lateral epicondylitis. Copyright © 2011. Published by Elsevier Inc.

  2. Effects of Postmortem Freezing on Passive Properties of Rabbit Extensor Digtorum Longus Muscle Tendon Complex

    DTIC Science & Technology

    1993-06-14

    AD-A266 429 INSTITUTE REPORT NO. 483 Effects of Postmortem Freezing on Passive Properties of Rabbit Extensor Digtorum Longus Muscle Tendon Complex D...Extensor Digtorum Longus Muscle Tendon Complex -- Paul H. Leitschuh, Tammy J. Doherty, Dean C. Taylor, Daniel E. Brooks, John B. Ryan This document has...ABSTRACT The tensile properties of the extensor digitorum longus muscle tendon unit (EDL MTU) were studied in 16 white male New Zealand rabbits in both

  3. Open extensor tendon injuries: an epidemiologic study.

    PubMed

    Patillo, Dominic; Rayan, Ghazi M

    2012-01-01

    To report the epidemiology, mechanism, anatomical location, distribution, and severity of open extensor tendon injuries in the digits, hand, and forearm as well as the frequency of associated injuries to surrounding bone and soft tissue. Retrospective chart review was conducted for patients who had operative repair of open digital extensor tendon injuries in all zones within an 11-year period. Data was grouped according to patient characteristics, zone of injury, mechanism of injury, and presence of associated injury. Statistical analysis was used to determine the presence of relevant associations. Eighty-six patients with 125 severed tendons and 105 injured digits were available for chart reviews. Patients were predominantly males (83%) with a mean age of 34.2 years and the dominant extremity was most often injured (60%). The thumb was the most commonly injured (25.7%), followed by middle finger (24.8), whereas small finger was least affected (10.5%). Sharp laceration was the most common mechanism of injury (60%), and most of these occurred at or proximal to the metacarpophalangeal joints. Most saw injuries occurred distal to the metacarpophalangeal joint. Zone V was the most commonly affected in the fingers (27%) while zone VT was the most commonly affected in the thumb (69%). Associated injuries to bone and soft tissue occurred in 46.7% of all injuries with saw and crush/avulsions being predictive of fractures and damage to the underlying joint capsule. The extensor mechanism is anatomically complex, and open injuries to the dorsum of the hand, wrist, and forearm, especially of crushing nature and those inflicted by saws, must be thoroughly evaluated. Associated injuries should be ruled out in order to customize surgical treatment and optimize outcome.

  4. Minimally invasive repair of the tibialis anterior tendon using a semitendinosus autograft.

    PubMed

    Michels, Frederick; Van Der Bauwhede, Jan; Oosterlinck, Dirk; Thomas, Sam; Guillo, Stéphane

    2014-03-01

    Ruptures of the tibialis anterior tendon are rare but can cause substantial functional deficiencies. The literature regarding the treatment of such injuries is very limited. Atraumatic ruptures often occur in the presence of an abnormal tendon structure, and retraction often makes end-to-end repair impossible. With traumatic lesions, the risk of developing both adhesions and scar tissue is high. This study assesses the results of a surgical reconstruction using the interposition of a semitendinosus tendon autograft in 12 patients. Three patients had a traumatic rupture, and 9 patients had an atraumatic rupture. In 8 patients, the procedure was carried out using a minimally invasive technique. The average postoperative American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot score was 95.7 in the atraumatic group and 94.7 in the traumatic group. Active dorsiflexion was possible after 2 to 3 weeks. We believe that the interposition of a strong, healthy tendon facilitated healing and allowed early weight bearing. All patients had good recovery of dorsiflexion and gait. Repairing a ruptured tibialis anterior tendon using a semitendinosus autograft was a reliable technique and offered a good result. With the minimally invasive approach, there was no need to divide the extensor retinaculum, which we believe allowed faster recovery and reduced the risk of adhesions and wound healing problems. Level IV, retrospective case series.

  5. Multiple variations of the tendons of the anatomical snuffbox.

    PubMed

    Thwin, San San; Fazlin, Fazlin; Than, Myo

    2014-01-01

    Multiple tendons of the abductor pollicis longus (APL) in the anatomical snuffbox of the wrist can lead to the development of de Quervain's syndrome, which is caused by stenosing tenosynovitis. A cadaveric study was performed to establish the variations present in the tendons of the anatomical snuffbox in a Malaysian population, in the hope that this knowledge would aid clinical investigation and surgical treatment of de Quervain's tenosynovitis. Routine dissection of ten upper limbs was performed to determine the variations in the tendons of the anatomical snuffbox of the wrist. In all the dissected upper limbs, the APL tendon of the first extensor compartment was found to have several (3-14) tendon slips. The insertion of the APL tendon slips in all upper limbs were at the base of the first metacarpal bone, trapezium and fascia of the opponens pollicis muscle; however, in seven specimens, they were also found to be attached to the fleshy belly of the abductor pollicis brevis muscle. In two specimens, double tendons of the extensor pollicis longus located in the third extensor compartment were inserted into the capsule of the proximal interphalangeal joints before being joined to the extensor expansion. In two other specimens, the first extensor compartment had two osseofibrous tunnels divided by a septum that separated the APL tendon from the extensor pollicis brevis tendon. Multiple variations were found in the anatomical snuffbox region of the dissected upper limbs. Knowledge of these variations would be useful in interventional radiology and orthopaedic surgery.

  6. Extensor Tendon Instability Due to Sagittal Band Injury in a Martial Arts Athlete: A Case Report.

    PubMed

    Kochevar, Andrew; Rayan, Ghazi

    2017-03-01

    A Taekwondo participant sustained a hand injury from punching an opponent that resulted in painful instability of the ring finger extensor digitorum communis tendon due to sagittal band damage. His symptoms resolved after reconstructive surgery on the sagittal band (SB) with stabilization of the extensor tendon over the metacarpophalangeal joint.

  7. Tendon rupture associated with excessive smartphone gaming.

    PubMed

    Gilman, Luke; Cage, Dori N; Horn, Adam; Bishop, Frank; Klam, Warren P; Doan, Andrew P

    2015-06-01

    Excessive use of smartphones has been associated with injuries. A 29-year-old, right hand-dominant man presented with chronic left thumb pain and loss of active motion from playing a Match-3 puzzle video game on his smartphone all day for 6 to 8 weeks. On physical examination, the left extensor pollicis longus tendon was not palpable, and no tendon motion was noted with wrist tenodesis. The thumb metacarpophalangeal range of motion was 10° to 80°, and thumb interphalangeal range of motion was 30° to 70°. The clinical diagnosis was rupture of the left extensor pollicis longus tendon. The patient subsequently underwent an extensor indicis proprius (1 of 2 tendons that extend the index finger) to extensor pollicis longus tendon transfer. During surgery, rupture of the extensor pollicis longus tendon was seen between the metacarpophalangeal and wrist joints. The potential for video games to reduce pain perception raises clinical and social considerations about excessive use, abuse, and addiction. Future research should consider whether pain reduction is a reason some individuals play video games excessively, manifest addiction, or sustain injuries associated with video gaming.

  8. Anatomic relationship of the proximal nail matrix to the extensor hallucis longus tendon insertion.

    PubMed

    Palomo López, P; Becerro de Bengoa Vallejo, R; López López, D; Prados Frutos, J C; Alfonso Murillo González, J; Losa Iglesias, M E

    2015-10-01

    The purpose of this study was to delineate the relationship of the terminal extensor hallucis longus tendon insertion to the proximal limit of the nail matrix of the great toe. Fifty fresh-frozen human cadaver great toes with no evidence of trauma (average age, 62.5 years; 29 males and 21 females) were used for this study. Under 25X magnification, the proximal limit of the nail matrix and the terminal bony insertion of the extensor hallucis longus tendons were identified. The distance from the terminal tendon insertion to the nail matrix was ascertained using precision calipers, an optical microscope, and autocad(®) software for windows. Twenty-five great toes were placed in a neutral formalin solution and further analysed by histological longitudinal-sections. The specimens were stained with haematoxylin and eosin and examined microscopically to determine the presence of the extensor hallucis longus tendon along the dorsal aspect of the distal phalanx of each great toe. The main result we found in great toes was that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx in all, 100%, specimens. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of the distal phalanx as is the case for fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. We have found that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of distal phalanx as is the case in fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. Our anatomic study demonstrates that the proximal limit of the matrix and nail bed of the human great toe are dorsal and overlapping the terminal extensor hallucis longus tendon until its distal bony insertion in all specimens. © 2015 European Academy of Dermatology and Venereology.

  9. Multiple variations of the tendons of the anatomical snuffbox

    PubMed Central

    Thwin, San San; Zaini, Fazlin; Than, Myo

    2014-01-01

    INTRODUCTION Multiple tendons of the abductor pollicis longus (APL) in the anatomical snuffbox of the wrist can lead to the development of de Quervain's syndrome, which is caused by stenosing tenosynovitis. A cadaveric study was performed to establish the variations present in the tendons of the anatomical snuffbox in a Malaysian population, in the hope that this knowledge would aid clinical investigation and surgical treatment of de Quervain's tenosynovitis. METHODS Routine dissection of ten upper limbs was performed to determine the variations in the tendons of the anatomical snuffbox of the wrist. RESULTS In all the dissected upper limbs, the APL tendon of the first extensor compartment was found to have several (3–14) tendon slips. The insertion of the APL tendon slips in all upper limbs were at the base of the first metacarpal bone, trapezium and fascia of the opponens pollicis muscle; however, in seven specimens, they were also found to be attached to the fleshy belly of the abductor pollicis brevis muscle. In two specimens, double tendons of the extensor pollicis longus located in the third extensor compartment were inserted into the capsule of the proximal interphalangeal joints before being joined to the extensor expansion. In two other specimens, the first extensor compartment had two osseofibrous tunnels divided by a septum that separated the APL tendon from the extensor pollicis brevis tendon. CONCLUSION Multiple variations were found in the anatomical snuffbox region of the dissected upper limbs. Knowledge of these variations would be useful in interventional radiology and orthopaedic surgery. PMID:24452976

  10. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

    PubMed

    Deng, Kai; Sun, Cong; Liu, Cheng; Ma, Rui

    2009-01-01

    To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT). Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies. Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly. Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

  11. Small flake, big problem: an unreported cause of extensor pollicis longus tendon rupture.

    PubMed

    Durrant, C A T; Bantick, G

    2010-01-01

    Fracture of the base of the third metacarpal with associated avulsion of the extensor carpi radialis brevis tendon is a rare injury. We report such a fracture and the unusual resulting complication of division of the extensor pollicis longus tendon by the avulsed bony fragment. Careful monitoring using lateral radiographs is needed to make the diagnosis and displacement of the avulsed fragment warrants open reduction and internal fixation.

  12. Lateral epicondylosis and calcific tendonitis in a golfer: a case report and literature review

    PubMed Central

    Yuill, Erik A.; Lum, Grant

    2011-01-01

    Objective To detail the progress of a young female amateur golfer who developed chronic left arm pain while playing golf 8 months prior to her first treatment visit. Clinical Features Findings included pain slightly distal to the lateral epicondyle of the elbow, decreased grip strength, and positive orthopedic testing. Diagnostic ultrasound showed thickening of the common extensor tendon origin indicating lateral epicondylosis. Radiographs revealed an oval shaped calcified density in the soft tissue adjacent to the lateral humeral epicondyle, indicating calcific tendonitis of the common extensor tendon origin. Intervention and Outcome Conventional care was aimed at decreasing the repetitive load on the common extensor tendon, specifically the extensor carpi radialis brevis. Soft tissue techniques, exercises and stretches, and an elbow brace helped to reduce repetitive strain. Outcome measures included subjective pain ratings, and follow up imaging 10 weeks after treatment began. Conclusion A young female amateur golfer with chronic arm pain diagnosed as lateral epicondylosis and calcific tendonitis was relieved of her pain after 7 treatments over 10 weeks of soft tissue and physical therapy focusing specifically on optimal healing and decreasing the repetitive load on the extensor carpi radialis brevis. PMID:22131570

  13. Remitting seronegative symmetrical synovitis with pitting edema (RS3PE) syndrome: ultrasonography as a diagnostic tool.

    PubMed

    Agarwal, Vikas; Dabra, Ajay Kumar; Kaur, Ravinder; Sachdev, Atul; Singh, Ram

    2005-09-01

    Remitting seronegative symmetrical synovitis with pitting edema (RS3PE) syndrome is characterized by symmetrical synovitis and swelling of both the upper and lower extremities. The anatomical determinant of RS3PE is predominantly extensor tenosynovitis as revealed by magnetic resonance imaging (MRI). Given the cost constraints, time, and expertise required in carrying out MRI and ease in diagnosing tenosynovitis by ultrasound, we utilized high-frequency ultrasonography (USG) for evidence of tenosynovitis of the distal tendons in patients with RS3PE. Diagnosis of tenosynovitis was made on the basis of anechoic or hypoechoic signals around the tendon sheaths in both transverse and longitudinal planes. Flexor and extensor tendons at the wrist and metacarpal heads and extensor digitorum longus (EDL) tendons at the ankle were evaluated with a 7.5-10-MHz linear probe. There were ten patients (seven males) with a mean age of 59.5 years (range: 52-78 years) and mean disease duration of 6.1 months (range: 1.5-12 months). Disease onset was acute in all of the cases. Pitting edema of the hands was present in all except two patients whereas four patients, in addition, had edema of the feet. Edema was symmetrical in seven patients. Inability to make a complete fist was noted in all. Tenosynovitis of extensor and flexor tendons at the wrist and the metacarpal heads was documented in all patients with edema of the hands. In seven cases extensor tendon tenosynovitis was more prominent compared to the flexor tendons. Tenosynovitis of EDL tendons was detected in six cases. Dramatic relief with low-dose prednisolone was noted in all patients within 6 weeks of therapy. At a mean follow-up of 10.1 months all patients had marked relief in edema of extremities and improvement in the grip strength. Our study confirms that tenosynovitis of both flexor and extensor tendons at the wrist and extensor tendons of the feet is the hallmark of RS3PE syndrome. USG is a reliable and cost-effective modality for evaluation of patients with suspected RS3PE.

  14. Treatment of peroneal tendon dislocation and coexisting medial and lateral ligamentous laxity in the ankle joint.

    PubMed

    Ziai, Pejman; Sabeti-Aschraf, Manuel; Fehske, Kai; Dlaska, Constantin E; Funovics, Philipp; Wenzel, Florian; Graf, Alexandra; Buchhorn, Tomas

    2011-06-01

    Acute dislocation of the peroneal tendon is caused by massive combined flexion-torsion trauma supported by preexisting ligamentous laxity of the ankle joint. This study aimed to investigate the clinical outcome of combined treatment of peroneal tendon dislocation and lateral and medial ligamentous laxity. Between 2005 and 2007, forty-two patients with peroneal tendon dislocation and coexisting ligamentous laxity were treated. The superior extensor retinaculum was reconstructed using anchor technique and periosteal flap repair, whereas the preexisting ligamentous laxity with regard to the extensor inferior retinaculum was addressed using anchor reconstruction. All patients underwent arthroscopy prior to surgery. Thirty-eight of a total of 42 patients (aged 17-31) completed the 24-month follow-up. Clinical and arthroscopic examination was accomplished consistently by always the same two surgeons. Postoperative follow-up comprised clinical evaluation after 3, 6, 12 and 24 months. Clinical results showed a significant (P<0.0001) increase in the AOFAS-Hindfoot Score as an often used but not validated outcome measure, as well as a significant decrease in the Visual Analogue Scale and in the internal and external rotation, after 3 months. The clinical outcome was confirmed at the 6-, 12- and 24-months measuring points. No dislocation of the peroneal tendon recurred within the 24-month follow-up. Subjective patient satisfaction was stated as high. Combined treatment of peroneal tendon dislocation and coexisting lateral and medial ligamentous laxity in the ankle joint following arthroscopy results in good clinical outcome and high patient satisfaction. Case series, Level IV.

  15. Extensor Tendon Injuries

    MedlinePlus

    ... the Hand. Find a hand surgeon near you. Videos Figures Figure 1 - Extensor tendons, located on the ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  16. Long-term outcomes following plate stabilization to address spontaneous luxation of the long digital extensor tendon of origin in 2 dogs.

    PubMed

    Hasiuk, Michelle M M; Drygas, Kevin A; Lewis, Daniel D

    2017-11-01

    Two dogs with spontaneous luxation of the long digital extensor tendon of origin were managed by performing a sulcoplasty and applying a plate bridging the extensor sulcus. Lameness resolved and neither dog had recurrence of lameness 59 and 15 months following surgery.

  17. Clinical Sign for Missed Decompression of a Separate Extensor Pollicis Brevis Compartment in de Quervain's Disease.

    PubMed

    Benatar, Niels

    2017-08-01

    Persistent pain despite previous surgery for de Quervain's disease might be due to an overlooked septum between the abductor pollicis longus tendon slips and the extensor pollicis brevis tendon, or an overlooked completely separate compartment for the extensor pollicis brevis tendon alone. In both of these instances, extension of the MP joint of the thumb against resistance elicits pain at the distal level of the first extensor compartment of the wrist. When this sign is positive, revisional surgery and decompression of the remaining septum or separate compartment is indicated. © Georg Thieme Verlag KG Stuttgart · New York.

  18. [Reconstruction of the extensor pollicis longus tendon by transposition of the extensor indicis tendon].

    PubMed

    Loos, A; Kalb, K; Van Schoonhoven, J; Landsleitner Dagger, B

    2003-12-01

    Rupture of the extensor pollicis longus-tendon (EPL) is a frequent complication after distal radius fractures. Other traumatic and non-traumatic reasons for this tendon lesion are known, including a theory about a disorder in the blood supply to the tendon itself. We examined 40 patients after reconstruction of the EPL-tendon in a mean follow-up time of 30 months. All patients were clinically examined and a DASH questionnaire was answered by all patients. The method to reconstruct the EPL-tendon was the transposition of the extensor indicis-tendon. After the operations the thumb was put in a splint for four weeks in a "hitch-hiker's-position". 31 ruptures of the tendon (77.5 %) were a result of trauma. In 20 of them (50 %) a distal radius fracture had occurred. Clinical examination included measurements of the movement of the thumb- and index-finger joints, the grip strength and the maximal span of the hand. Significant differences were not found. The isolated extension of the index finger was possible in all patients. But it was reduced in ten cases which represent 25 %. Our results were evaluated by the Geldmacher score to evaluate the reconstruction of the EPL-tendon. 20 % excellent, 65 % good, 12.5 % fair and 2.5 % poor results were reached. The Geldmacher score was used critically. We suggest its modification for the evaluation of thumb abduction. The DASH score reached a functional value of ten points which represents a very good result. In conclusion the extensor indicis-transposition is a safe method to reconstruct the EPL-tendon. Its substantial advantage is taking a healthy muscle as the motor, thereby avoiding the risk of using a degenerated muscle in late tendon reconstruction. A powerful extension of the index finger will be maintained by physical education. Generally, the loss of the extension of the index finger is negligible. It does not disturb the patients. But it has to be discussed with the patient before the operation.

  19. A Reconstructive Stabilization Technique for Nontraumatic or Chronic Traumatic Extensor Tendon Subluxation.

    PubMed

    Lee, Jae Hoon; Baek, Jong Hun; Lee, Jung Seok

    2017-01-01

    Subluxation of the extensor tendon results from a disruption to the sagittal band at the metacarpophalangeal joint. When conservative treatment fails to correct the subluxation, surgical treatment may be necessary. Surgical techniques for chronic cases vary in graft source and graft pathway. We present a surgical technique to recentralize and stabilize the extensor tendon using a residual ruptured sagittal band. This technique is simple and effective without donor site morbidity and seems to provide potential biomechanical advantages by restoring nearly normal anatomy. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Polypropylene mesh augmentation for complete quadriceps rupture after total knee arthroplasty.

    PubMed

    Nodzo, Scott R; Rachala, Sridhar R

    2016-01-01

    Polypropylene mesh has previously been shown to be an effective treatment for failed patellar tendon repairs after total knee arthroplasty (TKA), but there have been few reports of this synthetic mesh used in complete quadriceps rupture after TKA. We retrospectively reviewed seven consecutive cases in six patients with complete quadriceps tears after TKA who had their quadriceps tendon repaired with suture and polypropylene mesh augmentation. All but two patients had previously failed primary suture repair. Patient outcomes were evaluated using the Knee Society Score. Standardized anterior-posterior (AP), lateral and merchant radiographs were evaluated preoperatively and at final follow-up. Seven knees in six patients were evaluated with a mean follow-up of 34±10 (range 24 to 49months) months. There were only four clinical successes defined as an extensor lag less than 30°. Of the functioning knees at final follow-up (n=5) the overall extensor lag in this group did significantly improve from 50±13° to 20±15° (range 5 to 40°) (p=.01). Mean postoperative flexion at final follow-up was 115±8°. Mean Knee Society Score for function improved from 20±30 to 45±54 (p=.03) as did the mean Knee Society Score for pain (44±18 vs. 74±78, p=.02). Polypropylene mesh offered limited postoperative functional results when used as an augment to the multiply operated knee that sustains a complete quadriceps rupture after TKA, but did allow for significant improvement in postoperative pain outcomes. IV. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Anatomic factors related to the cause of tennis elbow.

    PubMed

    Bunata, Robert E; Brown, David S; Capelo, Roderick

    2007-09-01

    The pathogenesis of lateral epicondylitis remains unclear. Our purpose was to study the anatomy of the lateral aspect of the elbow under static and dynamic conditions in order to identify bone-to-tendon and tendon-to-tendon contact or rubbing that might cause abrasion of the tissues. Eighty-five cadaveric elbows were examined to determine details related to the bone structure and musculotendinous origins. We identified the relative positions of the musculotendinous units and the underlying bone when the elbow was in different degrees of flexion. We also recorded the contact between the extensor carpi radialis brevis and the lateral edge of the capitellum as elbow motion occurred, and we sought to identify the areas of the capitellum and extensor carpi radialis brevis where contact occurs. The average site of origin of the extensor carpi radialis brevis on the humerus lay slightly medial and superior to the outer edge of the capitellum. As the elbow was extended, the undersurface of the extensor carpi radialis brevis rubbed against the lateral edge of the capitellum while the extensor carpi radialis longus compressed the brevis against the underlying bone. The extensor carpi radialis brevis tendon has a unique anatomic location that makes its undersurface vulnerable to contact and abrasion against the lateral edge of the capitellum during elbow motion.

  2. Conservative management of partial extensor tendon lacerations greater than half the width of the tendon in manual workers.

    PubMed

    Al-Qattan, Mohammad M

    2015-04-01

    Conservative management (without suturing or splints) of partial extensor tendon lacerations greater than half the width of the tendon has not been previously investigated. In this prospective study, a total of 45 injured tendons (with lacerations involving 55%-90% of the width of the tendon) in 39 patients were treated conservatively. Injury zones I, III, and V of the fingers; and zones I and III of the thumb were excluded. Immediate non-resistive active mobilization was initiated and continued for 4 weeks, followed by resistive exercises. Patients were allowed to go back to work after 6 weeks. There were no cases of ruptures, triggering, infection, or complex regional pain syndrome. At final follow-up (8-9 months after injury), all patients obtained full range of motion with no extension lags. All patients were able to go back to normal duties. We conclude that early active motion without the use of splints or sutures in major extensor tendon lacerations in zones II, IV, VI-VIII of the fingers; and zones II, IV, and V of the thumb is safe.

  3. [The Omega "Omega" pulley plasty: a new technique for the surgical management of the De Quervain's disease].

    PubMed

    Bakhach, J; Sentucq-Rigal, J; Mouton, P; Boileau, R; Panconi, B; Guimberteau, J-C

    2006-02-01

    The Omega "Omega" pulley plasty: a new technique for the surgical management of the De Quervain's disease. The De Quervain tenosynovitis is an inadequacy into the first extensor compartment between the osteo-fibrous tunnel and the tendons. This mechanical conflict generates a tenosynovitis of the extensor pollicis brevis and the abductor pollicis longus tendons. This is generally expressed by a tenderness on the radial side of the wrist over the radial styloid process. The medical management consists on corticoids infiltrations of the first extensor compartment, the avoidance of repetitive and stress movements of the first ray with the use of a rest splint. The surgical approach is considered with the recurrence of the painful symptoms. This well-known pathology is reputated to require a simple section of the pulley. Our post-operative complications have been reported in the literature of this classical surgical solution. These complications concern an incomplete release of the extensor pollicis brevis and the abductor pollicis longus tendons particularly when an extensor sub-compartment exists and was overlooked, an irritation of the collateral branches of the sensitive radial nerve or the occurrence of a nevroma after a nerve injury and the most serious complication is a palmar subluxation of the extensor tendons which can occur with the thumb extended and the wrist flexed. In rare cases, this subluxation can be really painful and requires a surgical management with secondary reconstruction of the pulley. This reconstruction necessitates distal pedicle flaps from the dorsal retinaculum or the brachioradialis tendon. To prevent these complications, Codega and Kapandji described techniques of reconstruction of the pulley after its release. More recently, Le Viet reported a procedure using the anterior flap of the pulley; fixed to the dermis it will work as a barrier and maintain the tendons sliding on the radial styloid groove. These techniques require to divide the pulley and to reconstruct it suturing the different flaps. It can generate adherences between the extensor tendons, the overlying skin and the collateral branches of the radial nerve. The authors present a new and original plasty procedure of the first extensor compartment pulley, the "Omega" Omega plasty. It consists to liberate the anterior attachment of the pulley over the anterior lip of the styloïd process respecting its continuity with the periosteum flap. This conservative procedure is very interesting; it permits enough expansion of the tunnel volume decompressing the extensor tendons as a treatment of the De Quervain disease and respecting the anatomy and the continuity of the osteo-fibrous tunnel. This technique is simple, reliable and respects the first ray extensor tendons gliding physiology and biodynamic. In spite of our short clinical experience with only ten cases, all the patients retrieve a normal function of the thumb with complete disappearance of the first ray tenderness and pain without any complications. These preliminary results are encouraging and push us to consider the "Omega" plasty as a first choice for the surgical treatment of the De Quervain tenosynovitis.

  4. [Secondary tendon reconstruction on the thumb].

    PubMed

    Bickert, B; Kremer, T; Kneser, U

    2016-12-01

    Closed tendon ruptures of the thumb that require secondary reconstruction can affect the extensor pollicis longus (EPL), extensor pollicis brevis (EPB) and flexor pollicis longus (FPL) tendons. Treatment of rupture of the EPB tendon consists of refixation to the bone and temporary transfixation of the joint. In the case of preexisting or posttraumatic arthrosis, definitive arthrodesis of the thumb is the best procedure. Closed ruptures of the EPL and FPL tendons at the wrist joint cannot be treated by direct tendon suture. Rupture of the EPL tendon occurs after distal radius fractures either due to protruding screws or following conservative treatment especially in undisplaced fractures. Transfer of the extensor indicis tendon to the distal EPL stump is a good option and free interposition of the palmaris longus tendon is a possible alternative. The tension should be adjusted to slight overcorrection, which can be checked intraoperatively by performing the tenodesis test. Closed FPL ruptures at the wrist typically occur 3-6 months after osteosynthesis of distal radius fractures with palmar plates and are mostly characterized by crepitation and pain lasting for several weeks. They can be prevented by premature plate removal, synovectomy and carpal tunnel release. For treatment of a ruptured FPL tendon in adult patients the options for tendon reconstruction should be weighed up against the less complicated tenodesis or arthrodesis of the thumb interphalangeal joint.

  5. Collagen fibrils in functionally distinct tendons have differing structural responses to tendon rupture and fatigue loading.

    PubMed

    Herod, Tyler W; Chambers, Neil C; Veres, Samuel P

    2016-09-15

    In this study we investigate relationships between the nanoscale structure of collagen fibrils and the macroscale functional response of collagenous tissues. To do so, we study two functionally distinct classes of tendons, positional tendons and energy storing tendons, using a bovine forelimb model. Molecular-level assessment using differential scanning calorimetry (DSC), functional crosslink assessment using hydrothermal isometric tension (HIT) analysis, and ultrastructural assessment using scanning electron microscopy (SEM) were used to study undamaged, ruptured, and cyclically loaded samples from the two tendon types. HIT indicated differences in both crosslink type and crosslink density, with flexor tendons having more thermally stable crosslinks than the extensor tendons (higher TFmax of >90 vs. 75.1±2.7°C), and greater total crosslink density than the extensor tendons (higher t1/2 of 11.5±1.9 vs. 3.5±1.0h after NaBH4 treatment). Despite having a lower crosslink density than flexor tendons, extensor tendons were significantly stronger (37.6±8.1 vs. 23.1±7.7MPa) and tougher (14.3±3.6 vs. 6.8±3.4MJ/m(3)). SEM showed that collagen fibrils in the tougher, stronger extensor tendons were able to undergo remarkable levels of plastic deformation in the form of discrete plasticity, while those in the flexor tendons were not able to plastically deform. When cyclically loaded, collagen fibrils in extensor tendons accumulated fatigue damage rapidly in the form of kink bands, while those in flexor tendons did not accumulate significant fatigue damage. The results demonstrate that collagen fibrils in functionally distinct tendons respond differently to mechanical loading, and suggests that fibrillar collagens may be subject to a strength vs. fatigue resistance tradeoff. Collagen fibrils-nanoscale biological cables-are the fundamental load-bearing elements of all structural human tissues. While all collagen fibrils share common features, such as being composed of a precise quarter-staggered polymeric arrangement of triple-helical collagen molecules, their structure can vary significantly between tissue types, and even between different anatomical structures of the same tissue type. To understand normal function, homeostasis, and disease of collagenous tissues requires detailed knowledge of collagen fibril structure-function. Using anatomically proximate but structurally distinct tendons, we show that collagen fibrils in functionally distinct tendons have differing susceptibilities to damage under both tensile overload and cyclic fatigue loading. Our results suggest that the structure of collagen fibrils may lead to a strength versus fatigue resistance tradeoff, where high strength is gained at the expense of fatigue resistance, and vice versa. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  6. Autologous tenocyte injection for the treatment of severe, chronic resistant lateral epicondylitis: a pilot study.

    PubMed

    Wang, Allan; Breidahl, William; Mackie, Katherine E; Lin, Zhen; Qin, An; Chen, Jimin; Zheng, Ming H

    2013-12-01

    Severe chronic lateral epicondylitis (LE) is associated with degenerative tendon changes, extracellular matrix breakdown, and tendon cell loss. On the basis of positive outcomes from preclinical studies, this study is the first clinical trial of autologous tenocyte injection (ATI) on severe tendinopathy associated with chronic LE. Autologous tenocyte injection is a safe and effective procedure that enables a reduction in pain and improvement in function in resistant LE. Case series; Level of evidence, 4. Patients with severe refractory LE underwent clinical evaluation and magnetic resonance imaging (MRI) before intervention. A patellar tendon needle biopsy was performed under local anesthetic, and tendon cells were expanded by in vitro culture. Tenocytes used for the injection were characterized by flow cytometry and real-time polymerase chain reaction. Autologous tenocytes were injected into the site of tendinopathy identified at the origin of the extensor carpi radialis brevis tendon under ultrasound guidance on a single occasion. Patients underwent serial clinical evaluations and repeat MRI at 12 months after intervention. A total of 20 consecutive patients were included in the study. Three patients withdrew consent after enrollment and before ATI. No adverse event was reported at either biopsy or injection sites. Furthermore, no infection or excessive fibroblastic reaction was found in any patient at the injection site. Clinical evaluation revealed an improvement in mean visual analog scale scores, for a maximum pain score from 5.94 at the initial assessment to 0.76 at 12 months (P < .001). Mean quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) and grip strength scores also significantly improved over the 12-month follow-up (QuickDASH score, 45.88 [baseline] to 3.84; grip strength, 20.17 kg [baseline] to 37.38 kg; P < .001). With use of a validated MRI scoring system, the grade of tendinopathy at the common extensor origin improved significantly by 12 months (P < .001). One patient elected to proceed to surgery 3 months after ATI following a reinjury at work. In this study, patients with chronic LE who had previously undergone an unsuccessful full course of nonoperative treatment showed significantly improved clinical function and structural repair at the origin of the common extensor tendon after ATI. This novel treatment is encouraging for the treatment of tendinopathy and warrants further evaluation.

  7. [The external patello-tibial transfixation (EPTT). Part II: Clinical application and results].

    PubMed

    Ishaque, B; Gotzen, L; Ziring, E; Petermann, J

    1999-07-01

    In part I of the paper the biomechanical and technical background of the EPTT using the MPT fixator and the indications for this procedure have been described. In part II we report about the clinical application of the EPTT in 67 patients with a wide spectrum of repairs and reconstructions of the extensor mechanism. 48 patients had fresh injuries, 18 of them with severe concomitant knee lesions and 19 patients had neglected rsp. unsuccessfully operated injuries. There were 4 deep infections, two of them related to the MPT fixator. In the patients with uneventful healing the fixator remained in place for 7.3 weeks in average. The clinical, isokinetic and radiological results were reviewed in 17 patients with an average follow-up time of 37.3 months. There were 5 patients with partial patellectomy and tendon reattachment because of lower patella pole comminution and 12 patients with tendon reattachment ruptured at the inferior patella pole or suture repair in midsubstance rupture. The clinical results according to the IKDC score were rated in 3 patients as normal, in 10 patients as nearly normal and in 4 patients as abnormal. This rating was highly dependend on the subjective judgement by the patients who considered their operated knees not as normal as the contralateral knees. From our clinical experiences and results we can derive that the EPTT enables the surgical management of extensor mechanism disruptions with a minimum of internal fixation material and provides a safe protection of the repairs and reconstructions during the healing period. The EPTT allows immediate unrestricted functional rehabilitation and early walking without crutches. Thus the EPTT represents an effective alternative to the patello-tibial cerclage with a wire or synthetic ligaments.

  8. Intramuscular Electrical Stimulation for Muscle Activation of the Tibialis Anterior After Surgical Repair: A Case Report.

    PubMed

    Hollis, Sharon; McClure, Philip

    2017-12-01

    Background Loss of voluntary activation of musculature can result in muscle weakness. External neuromuscular stimulation can be utilized to improve voluntary activation but is often poorly tolerated because of pain associated with required stimulus level. Intramuscular electrical stimulation requires much lower voltage and may be better tolerated, and therefore more effective at restoring voluntary muscle activation. Case Description A 71-year-old man sustained a rupture of the distal attachment of the tibialis anterior tendon. Thirty-two weeks after surgical repair, there was no palpable or visible tension development in the muscle belly or tendon. Dorsiflexion was dependent on toe extensors. Electrical stimulation applied via a dry needling placement in the muscle belly was utilized to induce an isometric contraction. Outcomes Five sessions of intramuscular electrical stimulation were delivered. By day 4 (second visit), the patient was able to dorsiflex without prominent use of the extensor hallucis longus. By day 6 (third visit), active-range-of-motion dorsiflexion with toes flexed increased 20° (-10° to 10°). Eighteen days after the initial treatment, the patient walked without his previous high-step gait pattern, and the tibialis anterior muscle test improved to withstanding moderate resistance (manual muscle test score, 4/5). Discussion The rapid change in muscle function observed suggests that intramuscular electrical stimulation may facilitate voluntary muscle activation. Level of Evidence Therapy, level 5. J Orthop Sports Phys Ther 2017;47(12):965-969. Epub 15 Oct 2017. doi:10.2519/jospt.2017.7368.

  9. Technique of Dynamic Flexor Digitorum Superficialis Transfer to Lateral Bands for Proximal Interphalangeal Joint Deformity Correction in Severe Dupuytren Disease.

    PubMed

    Schreck, Michael J; Holbrook, Hayden S; Koman, L Andrew

    2018-02-01

    Pseudo-boutonniere deformity is an uncommon complication from long-standing proximal interphalangeal (PIP) joint contracture in Dupuytren disease. Prolonged flexion contracture of the PIP joint can lead to central slip attenuation and resultant imbalances in the extensor mechanism. We present a technique of flexor digitorum superficialis (FDS) tendon transfer to the lateral bands to correct pseudo-boutonniere deformity at the time of palmar fasciectomy for the treatment of Dupuytren disease. The FDS tendon is transferred from volar to dorsal through the lumbrical canal and sutured into the dorsally mobilized lateral bands. This technique presents an approach to the repair of pseudo-boutonniere deformity in Dupuytren disease. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. Proximity of arthroscopic ankle stabilization procedures to surrounding structures: an anatomic study.

    PubMed

    Drakos, Mark; Behrens, Steve B; Mulcahey, Mary K; Paller, David; Hoffman, Eve; DiGiovanni, Christopher W

    2013-06-01

    To examine the anatomy of the lateral ankle after arthroscopic repair of the lateral ligament complex (anterior talofibular ligament [ATFL] and calcaneofibular ligament [CFL]) with regard to structures at risk. Ten lower extremity cadaveric specimens were obtained and were screened for gross anatomic defects and pre-existing ankle laxity. The ATFL and CFL were sectioned from the fibula by an open technique. Standard anterolateral and anteromedial arthroscopy portals were made. An additional portal was created 2 cm distal to the anterolateral portal. The articular surface of the fibula was identified, and the ATFL and CFL were freed from the superficial and deeper tissues. Suture anchors were placed in the fibula at the ATFL and CFL origins and were used to repair the origin of the lateral collateral structures. The distance from the suture knot to several local anatomic structures was measured. Measurements were taken by 2 separate observers, and the results were averaged. Several anatomic structures lie in close proximity to the ATFL and CFL sutures. The ATFL sutures entrapped 9 of 55 structures, and no anatomic structures were inadvertently entrapped by the CFL sutures. The proximity of the peroneus tertius and the extensor tendons to the ATFL makes them at highest risk of entrapment, but the proximity of the intermediate branch of the superficial peroneal nerve (when present) is a risk with significant morbidity. Our results indicate that the peroneus tertius and extensor tendons have the highest risk for entrapment and show the smallest mean distances from the anchor knot to the identified structure. Careful attention to these structures, as well as the superficial peroneal nerve, is mandatory to prevent entrapment of tendons and nerves when one is attempting arthroscopic lateral ankle ligament reconstruction. Defining the anatomic location and proximity of the intervening structures adjacent to the lateral ligament complex of the ankle may help clarify the anatomic safe zone through which arthroscopic repair of the lateral ligament complex can be safely performed. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. Mechanical Strength of the Side-to-Side Tendon Attachment for Mismatched Tendon Sizes and Shapes

    PubMed Central

    Fridén, Jan; Tirrell, Timothy F.; Bhola, Siddharth; Lieber, Richard L.

    2015-01-01

    Summary Certain combinations are advised against in tendon transfers due to size or shape mismatches between donor and recipient tendons. In this study, ultimate load, stiffness and Young’s modulus were measured in two tendon-to-tendon attachments with intentionally mismatched donor and recipient tendons - pronator teres (PT)-to-extensor carpi radialis brevis (ECRB) and flexor carpi ulnaris (FCU)-to-extensor digitorum communis (EDC). FCU-EDC attachments failed at higher loads than PT-to-ECRB attachments but they had similar modulus and stiffness values. Ultimate tensile strength of the tendon attachments exceeded the maximum predicted contraction force of any of the affected muscles, with safety factors of 4x and 2x for the FCU-to-EDC and PT-to-ECRB constructs, respectively. This implies that size and shape mismatch should not be a contraindication to tendon attachment in transfers. Further, these safety factors strongly suggest that no postoperative immobilization of these attachments is necessary. PMID:24413573

  12. Chronic Quadriceps Tendon Rupture After Total Knee Arthroplasty Augmented With Synthetic Mesh.

    PubMed

    Ormaza, Amaia; Moreta, Jesús; Mosquera, Javier; de Ugarte, Oskar Sáez; Mozos, José Luis Martinez-de Los

    2017-01-01

    Tear of the quadriceps tendon after revision or primary total knee arthroplasty is a rare complication, but when it occurs, this injury has serious functional consequences. In complete tears, the outcome of direct repair is unpredictable, and several authors recommend that the suture should be reinforced. Several techniques have been described, including the use of autografts, allografts, and synthetic mesh. The goal of this study was to assess the outcomes of a reconstruction technique augmented with synthetic mesh. A retrospective study was performed involving 3 patients who had chronic partial quadriceps tendon tear after total knee revision. In 2 cases, proximal quadriceps release was performed. When conservative management failed, surgical reconstruction with suture reinforced with synthetic mesh was attempted. The knee was immobilized in full extension for 6 weeks after the surgical procedure. A minimum follow-up of 12 months was required to assess results. All reconstructions showed clinical success at a mean follow-up of 19 months. Mean Knee Society Score improved from 55.7 to 87.3, with average postoperative extensor lag of 3.3° (range, 0°-10°). The mean visual analog scale pain score was 2.3 (range, 0-4). No complications were reported. Synthetic mesh has previously been shown to be an effective treatment for patellar tendon repairs after total knee replacement, but there have been few articles on quadriceps rupture. Surgical reconstruction with synthetic mesh is a viable option that provides good functional outcomes in chronic quadriceps tendon rupture after total knee arthroplasty. [Orthopedics. 2017; 40(1):38-42.]. Copyright 2016, SLACK Incorporated.

  13. Repair of insertional achilles tendinosis with a bone-quadriceps tendon graft.

    PubMed

    Philippot, Rémi; Wegrzyn, Julien; Grosclaude, Sophie; Besse, Jean Luc

    2010-09-01

    While conservative treatment may be successful in most cases, partial rupture at the calcaneal insertion point is a significant concern with insertional Achilles tendinopathy. We report on the outcomes of a surgical technique for Achilles tendon augmentation using a bone-tendon graft harvested from the knee extensor system. Our retrospective case series includes 25 surgical procedures performed in 24 patients, 19 males and five females, with a mean age of 47 (range, 30 to 59) years, 18 of whom were athletes. The mean followup period was 52 (range, 12 to 156) months. All patients underwent MRI examination prior to surgery which showed partial Achilles tendon rupture. The Achilles tendon was debrided through a posterolateral approach. The bone-quadriceps tendon graft was harvested, then the bone plug of the graft was inserted into a blind tunnel drilled into the calcaneus and fixed with an interference screw. The fibers of the quadriceps tendon were sutured to the residual part of the Achilles tendon with the foot at an angle of 90 degrees. Patients were able to resume their sporting activity after an average of 6.7 months. At last followup examination, physical activity was scored 5.2 on the 10-point Tegner Scale; the mean AOFAS score was 98.4. MRI examination showed good graft integration 1 year postoperatively. The bone-quadriceps tendon grafting technique was a good alternative for the insertional Achilles lesions with partial detachment which we felt required augmentation.

  14. How are tonic and phasic cardiovascular changes related to central motor command?

    PubMed

    Jennings, J R; van der Molen, M W; Brock, K; Somsen, R J

    1993-07-01

    We examined the influence of central motor command on heart rate, respiration, and peripheral vascular activity. Central command was enhanced or reduced using tendon vibration. Muscle tension was held constant permitting the examination of variation in central command. Experiment 1 demonstrated in 13 college-aged males an enhancement of heart rate and vascular responses to an isometric, extensor contraction when vibration of the flexor tendon was added. Experiment 2 asked whether changes in central command interacted with phasic cardiovascular changes such as stimulus-linked anticipatory cardiac deceleration. Twenty college-aged males performed either an isometric flexor or extensor contraction with or without flexor tendon vibration. As expected, vibration enhanced cardiovascular change with extensor contraction more than with flexor contraction. Relative to control contractions, however, the flexor change was not an absolute decrease in cardiovascular change. More importantly, tendon vibration failed to alter phasic cardiovascular changes. Force and central commands for force induce cardiovascular change, but this change seems independent of phasic changes induced by the anticipation and processing of environmental stimuli.

  15. Reconstruction of long digital extensor tendon by cranial tibial muscle fascia graft in a dog.

    PubMed

    Sabiza, Soroush; Khajeh, Ahmad; Naddaf, Hadi

    2016-01-01

    Tendon rupture in dogs is generally the result of a direct trauma. This report described the use of adjacent muscle autogenic fascial graft for reconstruction of distal rupture of long digital extensor tendon in a dog. A two-year-old male mix breed dog, was presented with a non-weight bearing lameness of the right hind limb and a deep rupture of lateral side of right tarsus. History taking revealed that this rupture appeared without any apparent cause, when walking around the farm, three days before. Radiography was done and no fracture was observed. Hyperextension of right tarsal joint compared to left limb was observed. Under general anesthesia, after dissections of the ruptured area, complete rupture of long digital extensor tendon was revealed. Then, we attempted to locate the edge of the tendon, however, the tendon length was shortened approximately 1 cm. Hence, a strip of 1 cm length from fascia of cranial tibial muscle was harvested to fill the defect. The graft was sutured to the two ends of tendon using locking loop pattern. Subcutaneous layers and the skin were sutured routinely. Ehmer sling bandage was applied to prevent weight bearing on the surgical region. Re-examination and phone contact with the owner eight weeks and six months postoperatively revealed a poor lameness and excellent function of the dog, respectively. It could be concluded that the fascia of adjacent muscles can be used as an autogenic graft for reconstruction of some tendon ruptures.

  16. Reconstruction of long digital extensor tendon by cranial tibial muscle fascia graft in a dog

    PubMed Central

    Sabiza, Soroush; Khajeh, Ahmad; Naddaf, Hadi

    2016-01-01

    Tendon rupture in dogs is generally the result of a direct trauma. This report described the use of adjacent muscle autogenic fascial graft for reconstruction of distal rupture of long digital extensor tendon in a dog. A two-year-old male mix breed dog, was presented with a non-weight bearing lameness of the right hind limb and a deep rupture of lateral side of right tarsus. History taking revealed that this rupture appeared without any apparent cause, when walking around the farm, three days before. Radiography was done and no fracture was observed. Hyperextension of right tarsal joint compared to left limb was observed. Under general anesthesia, after dissections of the ruptured area, complete rupture of long digital extensor tendon was revealed. Then, we attempted to locate the edge of the tendon, however, the tendon length was shortened approximately 1 cm. Hence, a strip of 1 cm length from fascia of cranial tibial muscle was harvested to fill the defect. The graft was sutured to the two ends of tendon using locking loop pattern. Subcutaneous layers and the skin were sutured routinely. Ehmer sling bandage was applied to prevent weight bearing on the surgical region. Re-examination and phone contact with the owner eight weeks and six months postoperatively revealed a poor lameness and excellent function of the dog, respectively. It could be concluded that the fascia of adjacent muscles can be used as an autogenic graft for reconstruction of some tendon ruptures. PMID:27872726

  17. Multiple Giant Cell Tumor of Tendon Sheath Involving Both Flexor and Extensor Tendons in a Single Digit: A Case Report and Review of the Literatures.

    PubMed

    Min, Hak Jin; Kim, Jeong Hwan; Kim, Jae Woo; Yeom, Jae Woo

    2018-06-01

    Giant cell tumor of the tendon sheath (GCTTS) is a common neoplasm of the hand. This tumor is usually solitary. Multi focal origin of the tumor is considered unusual and very few cases of multiple GCTTS have been reported. We report a 48-year-old female patient who presented with three separate painless nodules in same index finger since three years. The two masses located on dorsal aspect, and the other one located on volar aspect. The imaging studies revealed three separated masses without any connection. We performed excisional biopsy and found multiple tumors, attached to flexor and extensor tendon. The final histopathologic diagnosis was GCTTS.

  18. Late extensor pollicis longus rupture following plate fixation in Galeazzi fracture dislocation

    PubMed Central

    Sabat, Dhananjaya; Dabas, Vineet; Dhal, Anil

    2014-01-01

    Late rupture of extensor pollicis longus (EPL) tendon after Galeazzi fracture dislocation fixation is an unknown entity though it is a well-established complication following distal radius fractures. We report the case of a 55-year old male who presented with late EPL tendon rupture 4 months following internal fixation of Galeazzi fracture dislocation with a Locking Compression Plate (LCP). He was managed with extensor indicis proprius (EIP) transfer to restore thumb extension. At 4 years followup, functional result of the transfer was good. We identify possible pitfalls with this particular patient and discuss how to avoid them in future. PMID:25143650

  19. The Incidence of Acute Traumatic Tendon Injuries in the Hand and Wrist: A 10-Year Population-based Study

    PubMed Central

    de Jong, Johanna P.; Nguyen, Jesse T.; Sonnema, Anne J. M.; Nguyen, Emily C.; Amadio, Peter C.

    2014-01-01

    Background Acute traumatic tendon injuries of the hand and wrist are commonly encountered in the emergency department. Despite the frequency, few studies have examined the true incidence of acute traumatic tendon injuries in the hand and wrist or compared the incidences of both extensor and flexor tendon injuries. Methods We performed a retrospective population-based cohort study of all acute traumatic tendon injuries of the hand and wrist in a mixed urban and rural Midwest county in the United States between 2001-2010. A regional epidemiologic database and medical codes were used to identify index cases. Epidemiologic information including occupation, year of injury, mechanism of injury and the injured tendon and zone were recorded. Results During the 10-year study period there was an incidence rate of 33.2 injuries per 100,000 person-years. There was a decreasing rate of injury during the study period. Highest incidence of injury occurred at 20-29 years of age. There was significant association between injury rate and age, and males had a higher incidence than females. The majority of cases involved a single tendon, with extensor tendon injuries occurring more frequently than flexor tendons. Typically, extensor tendon injuries involved zone three of the index finger, while flexor tendons involved zone two of the index finger. Work-related injuries accounted for 24.9% of acute traumatic tendon injuries. The occupations of work-related injuries were assigned to major groups defined by the 2010 Standard Occupational Classification structure. After assigning these patients' occupations to respective major groups, the most common groups work-related injuries occurred in construction and extraction occupations (44.2%), food preparation and serving related occupations (14.4%), and transportation and material moving occupations (12.5%). Conclusions Epidemiology data enhances our knowledge of injury patterns and may play a role in the prevention and treatment of future injuries, with an end result of reducing lost work time and economic burden. PMID:24900902

  20. Silicone infusion tubing instead of Hunter rods for two-stage zone 2 flexor tendon reconstruction in a resource-limited surgical environment.

    PubMed

    Kibadi, K; Moutet, F

    2017-10-01

    The authors describe their experience using silicone infusion tubing in place of Hunter rods for two-stage zone 2 flexor tendon reconstruction in a resource-limited surgical environment. This case report features a 47-year-old, right-handed man who had no active PIP and DIP joint flexion in four fingers of the right hand 5 months after an injury. During the first repair stage, the A2 and A4 pulleys were reconstructed using an extensor retinaculum graft. An infusion tube was inserted instead of Hunter rods. During the second stage, formation of a digital neo-canal around the infusion tubing was observed. The infusion tubing was removed and replaced with a palmaris longus tendon graft according to the conventional technique. Physiotherapy and rehabilitation followed surgery. At 6 months, very significant progress had been made with complete recovery of PIP and DIP flexion in the four fingers. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  1. [Complex trauma of the hand].

    PubMed

    Pechlaner, S; Hussl, H

    1998-01-01

    The hand is very exposed to injuries in the daily man's work. The multiple functions of the hand are based on vitality, sensibility, motor function and stability. In severe hand injuries the functional results of the repair are often very poor. In a complex injury of the hand we are faced with the damage of the soft tissue and bone and the loss of vitality and function of the hand. The cause of hand injuries are mainly a crush trauma or the rotating saw. Basically, we recommend an extended primary repair. After the radical debridement we have to reconstruct the damaged structures. We start doing the osteosynthesis and stabilization of the joints. Thereafter, suturing of extensor and flexor tendons. Then, we do the microsurgical reconstructions of vessels and nerves. In case tendons and bones are exposed we have to cover the defect with a pedicled or a free flap. In a long ischemic time we have to change our concept and do the reconstruction of the vessels first. Our results in vitality and sensibility are listed. In the result of a complex hand injury each single functional restoration is very important. Therefore, it is necessary that severe hand injuries are treated at well established centres for hand surgery.

  2. [Rupture of the tendon of the tibialis anterior muscle : Etiology, clinical symptoms and treatment].

    PubMed

    Waizy, H; Bouillon, B; Stukenborg-Colsman, C; Yao, D; Ettinger, S; Claassen, L; Plaass, C; Danniilidis, K; Arbab, D

    2017-12-01

    Ruptures of the tendon of the tibialis anterior muscle tend to occur in the context of degenerative impairments. This mainly affects the distal avascular portion of the tendon. Owing to the good compensation through the extensor hallucis longus and extensor digitorum muscles, diagnosis is often delayed. In addition to the clinical examination, magnetic resonance inaging (MRI) diagnostics are of particular importance, although damage or rupture of the tendon can also be demonstrated sonographically. Therapeutic measures include conservative or operative measures, depending on the clinical symptoms. Conservative stabilization of the ankle can be achieved by avoiding plantar flexion using a peroneal orthosis or an ankle-foot orthosis. Subsequent problems, such as metatarsalgia or overloading of the medial foot edge can be addressed by insoles or a corresponding shoe adjustment. An operative procedure is indicated when there is corresponding suffering due to pressure and functional impairment. The direct end-to-end reconstruction of the tendon is only rarely possible in cases of delayed diagnosis due to the degenerative situation and the retraction of the tendon stumps. Depending on the defect size and the tendon quality, various operative techniques, such as rotationplasty, free transplants or tendon transfer can be used.

  3. Extensor indicis proprius tendon transfer using shear wave elastography.

    PubMed

    Lamouille, J; Müller, C; Aubry, S; Bensamoun, S; Raffoul, W; Durand, S

    2017-06-01

    The means for judging optimal tension during tendon transfers are approximate and not very quantifiable. The purpose of this study was to demonstrate the feasibility of quantitatively assessing muscular mechanical properties intraoperatively using ultrasound elastography (shear wave elastography [SWE]) during extensor indicis proprius (EIP) transfer. We report two cases of EIP transfer for post-traumatic rupture of the extensor pollicis longus muscle. Ultrasound acquisitions measured the elasticity modulus of the EIP muscle at different stages: rest, active extension, active extension against resistance, EIP section, distal passive traction of the tendon, after tendon transfer at rest and then during active extension. A preliminary analysis was conducted of the distribution of values for this modulus at the various transfer steps. Different shear wave velocity and elasticity modulus values were observed at the various transfer steps. The tension applied during the transfer seemed close to the resting tension if a traditional protocol were followed. The elasticity modulus varied by a factor of 37 between the active extension against resistance step (565.1 kPa) and after the tendon section (15.3 kPa). The elasticity modulus values were distributed in the same way for each patient. The therapeutic benefit of SWE elastography was studied for the first time in tendon transfers. Quantitative data on the elasticity modulus during this test may make it an effective means of improving intraoperative adjustments. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  4. Flexor Tendon Repair With Looped Suture: 1 Versus 2 Knots.

    PubMed

    Gil, Joseph A; Skjong, Christian; Katarincic, Julia A; Got, Christopher

    2016-03-01

    To assess the strength of flexor tendon repair with looped suture. We hypothesized that, after passing the intact looped suture in the desired repair configuration, splitting the loop and tying 2 independent knots would increase the strength of flexor tendon repair. Thirty-two flexor tendons were harvested and were sharply transected in zone II. The tendons were repaired with a 4-strand core suture repair using 3-0 looped nonabsorbable nylon suture. The harvested tendons were randomly assigned and repaired with either a 1- or a 2-knot construct. The repaired flexor tendons were fixed in a servohydraulic material testing system and were loaded to failure either with uniaxial tension or cyclically. The average force at failure was 43 N for the 1-knot repair and 28 N for the 2-knot repair. The mode of failure of 15 of the flexor tendon repairs that were cyclically loaded to failure was suture pull-out. The average number of cycles and force in cyclic testing that caused failure of flexor tendon repairs was 134 cycles and 31 N for tendons repaired with looped 3-0 suture tied with 1 knot and 94 cycles and 33 N for tendons repaired with looped 3-0 suture tied with 2 knots. Our hypothesis was disproved by the results of this study. This study suggests that, when using looped suture, tying 2 independent knots instead of tying a single knot does not increase the strength of the flexor tendon repair. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. The effect of seprafilm on adhesion formation and tendon healing after flexor tendon repair in chicken.

    PubMed

    Yilmaz, Erhan; Avci, Mustafa; Bulut, Mehmet; Kelestimur, Halidun; Karakurt, Lokman; Ozercan, Ibrahim

    2010-03-01

    Adhesion of the tendon, which can occur during healing of tendon repair, is negatively affected by the outcome of surgery. In this experimental study, we sought to prevent adhesion of the tendon, and determined the mechanical stiffness of repair tissue by wrapping sodium hyaluronate and carboxymethylcellulose (Seprafilm; Genzyme, Cambridge, Massachusetts) around the repaired tendon segments. The study group comprised 2 groups of 20 chickens. In group I, the right gastrocnemius tendons of the chickens were cut smoothly, and after tendon and sheath repair, the skin was sutured. In group II, the right gastrocnemius tendons of the chickens were cut, the tendons were repaired, and before skin closure, Seprafilm was wrapped around the repaired tendon segments. Plastic splints were used for holding the chickens' ankles in a neutral position, and they were allowed weight bearing for 8 weeks. In group II, anatomic space between the tendon-sheath and tendon was clear and the tendon-sheath complex was sliding easily around the repaired tendon segment, and this complex was more functional both biomechanically and histologically. Also, the Seprafilm-applied tendons (group II) were observed to be biomechanically more resistant to the tensile forces in group I. Seprafilm is an easily applied interpositional material that can be used safely to prevent adhesion during the tendon healing process. Copyright 2010, SLACK Incorporated.

  6. Surface Modification Counteracts Adverse Effects Associated with Immobilization after Flexor Tendon Repair

    PubMed Central

    Zhao, Chunfeng; Sun, Yu-Long; Jay, Gregory D.; Moran, Steven L.; An, Kai-Nan; Amadio, Peter C.

    2012-01-01

    SUMMARY Although post-rehabilitation is routinely performed following flexor tendon repair, in some clinical scenarios post-rehabilitation must be delayed. We investigated modification of the tendon surface using carbodiimide derivatized hyaluronic acid and lubricin (cd-HA-Lub) to maintain gliding function following flexor tendon repair with postoperative immobilization in a in vivo canine model. Flexor digitorum profundus tendons from the 2nd and 5th digits of one forepaw of six dogs were transected and repaired. One tendon in each paw was treated with cd-HA-Lub; the other repaired tendon was not treated. Following tendon repair, a forearm cast was applied to fully immobilize the operated forelimb for 10 days, after which the animals were euthanized. Digit normalized work of flexion (nWOF) and tendon gliding resistance were assessed. The nWOF of the FDP tendons treated with cd-HA-Lub was significantly lower than the nWOF of the untreated tendons (p < 0.01). The gliding resistance of cd-HA-Lub treated tendons was also significantly lower than that of the untreated tendons (p < 0.05). Surface treatment with cd-HA-Lub following flexor tendon repair provides an opportunity to improve outcomes for patients in whom the post-operative therapy must be delayed after flexor tendon repair. PMID:22714687

  7. Gouty involvement of the patella and extensor mechanism of the knee mimicking aggressive neoplasm. A case series.

    PubMed

    Kester, Christopher; Wallace, Matthew T; Jelinek, James; Aboulafia, Albert

    2018-06-01

    Gout is a common inflammatory crystal deposition disease that occurs in many joints throughout the body. Active gout is most often associated with painful synovitis causing searing joint pains, but gout can also produce large masses of space-occupying deposits called tophi. Tophi are most frequently seen in juxta-articular locations with or without bony erosion and are often misdiagnosed as degenerative joint disease. Soft tissue deposits and tendon involvement are also known manifestations of gout, but can present with indeterminate and alarming findings on imaging. We present three cases of tophaceous gout mimicking aggressive neoplasms in the extensor mechanism of the knee. All cases presented as extensor tendon masses eroding into the patella, with imaging findings initially concerning for primary musculoskeletal malignancy.

  8. Patellar tendon re-rupture on the opposite end of the previous site of surgical repair

    PubMed Central

    KOH, Bryan Thean Howe; SAYAMPANATHAN, Andrew A; LEE, Keng Thiam

    2017-01-01

    We describe a rare case of a patellar tendon “re-rupture” at the opposite end of a previous proximal tendon repair. A 32-year-old male with a history of surgically repaired right proximal patellar tendon rupture presented with an acute non-traumatic right knee pain and instability during sports. Magnetic resonance imaging confirmed a complete rupture of his distal patellar tendon at the tibial tuberosity. The patellar tendon was repaired using two 5.5 mm BioCorkscrews (Arthrex) inserted into the tibial tuberosity; the tendon was stitched with the No. 2 fiberwires using Krackow technique. As the patellar tendon was degenerative, the repair was augmented with a semitendinosus tendon harvested using an open tendon stripper, leaving the distal attachment intact. At 2.6 years followup he had mild anterior knee pain, range of motion 0-130° and was able to squat. MRI scan done at followup revealed good healing of repaired patellar tendon. PMID:28566788

  9. The effect of muscle excursion on muscle recovery after tendon repair in a neglected tendon injury: a study in rabbit soleus muscles.

    PubMed

    Jeon, Suk Ha; Chung, Moon Sang; Baek, Goo Hyun; Lee, Young Ho; Gong, Hyun Sik

    2011-01-01

    We attempted to determine whether muscle excursion observed during operation can be a prognostic indicator of muscle recovery after delayed tendon repair in a rabbit soleus model. Eighteen rabbits underwent tenotomy of the soleus muscles bilaterally and were divided into three groups according to the period from tenotomy to repair. The tendons of each group were repaired 2, 4, and 6 weeks after tenotomy. The excursion of each soleus muscle was measured at the time of tenotomy (baseline), at 2, 4, 6 weeks after tenotomy, and 8 weeks after tendon repair. The amount of muscle recovery after tendon repair in terms of muscle excursion independently depended on the timing of repair and on the muscle excursion observed during repair. The regression model predicted that the muscle excursion recovered on average by 0.6% as the muscle excursion at the time of repair increased by 1% after adjusting for the timing of repair. This study suggests that measuring the muscle excursion during tendon repair may help physicians estimate the potential of muscle recovery in cases of delayed tendon repair. Copyright © 2010 Orthopaedic Research Society.

  10. Disabling hand injuries in boxing: boxer's knuckle and traumatic carpal boss.

    PubMed

    Melone, Charles P; Polatsch, Daniel B; Beldner, Steven

    2009-10-01

    This article describes the treatment of the two most debilitating hand-related boxing injuries: boxer's knuckle and traumatic carpal boss. Recognition of the normal anatomy as well as the predictable pathology facilitates an accurate diagnosis and precision surgery. For boxer's knuckle, direct repair of the disrupted extensor hood, without the need for tendon augmentation, has been consistently employed; for traumatic carpal boss, arthrodesis of the destabilized carpometacarpal joints has been the preferred method of treatment. Precisely executed operative treatment of both injuries has resulted in a favorable outcome, as in the vast majority of cases the boxers have experienced relief of pain, restoration of function, and an unrestricted return to competition.

  11. The V-Shaped Distal Triceps Tendon Repair: A Comparative Biomechanical Analysis.

    PubMed

    Scheiderer, Bastian; Imhoff, Florian B; Morikawa, Daichi; Lacheta, Lucca; Obopilwe, Elifho; Cote, Mark P; Imhoff, Andreas B; Mazzocca, Augustus D; Siebenlist, Sebastian

    2018-05-01

    Restoring footprint anatomy, minimizing gap formation, and maximizing the strength of distal triceps tendon repairs are essential factors for a successful healing process and return to sport. The novel V-shaped distal triceps tendon repair technique with unicortical button fixation closely restores footprint anatomy, provides minimal gap formation and high ultimate failure load, and minimizes iatrogenic fracture risk in acute/subacute distal triceps tendon tears. Controlled laboratory study. Twenty-four cadaveric elbows (mean ± SD age, 66 ± 5 years) were randomly assigned to 1 of 3 repair groups: the transosseous cruciate repair technique (gold standard), the knotless suture-bridge repair technique, and the V-shaped distal triceps tendon repair technique. Anatomic measurements of the central triceps tendon footprint were obtained in all specimens with a 3-dimensional digitizer before and after the repair. Cyclic loading was performed for a total of 1500 cycles at a rate of 0.25 Hz, pulling in the direction of the triceps. Displacements were measured on the medial and lateral tendon sites with 2 differential variable reluctance transducers. Load to failure and construct failure mode were recorded. The mean triceps bony insertion area was 399.05 ± 81.23 mm 2 . The transosseous cruciate repair technique restored 36.6% ± 16.8% of the native tendon insertion area, which was significantly different when compared with the knotless suture-bridge repair technique (85.2% ± 14.8%, P = .001) and the V-shaped distal triceps tendon repair technique (88.9% ± 14.8%, P = .002). Mean displacement showed no significant difference between the V-shaped distal triceps tendon repair technique (medial side, 0.75 ± 0.56 mm; lateral side, 0.99 ± 0.59 mm) and the knotless suture-bridge repair technique (1.61 ± 0.97 mm and 1.29 ± 0.8 mm) but significance between the V-shaped distal triceps tendon repair technique and the transosseous cruciate repair technique (4.91 ± 1.12 mm and 5.78 ± 0.9 mm, P < .001). Mean peak failure load of the V-shaped distal triceps tendon repair technique (732.1 ± 156.0 N) was significantly higher than that of the knotless suture-bridge repair technique (505.4 ± 173.9 N, P = .011) and the transosseous cruciate repair technique (281.1 ± 74.8 N, P < .001). Mechanism of failure differed among the 3 repairs, with the only olecranon fracture occurring in the knotless suture-bridge repair technique at the level of the lateral row suture anchors. At time zero, the V-shaped distal triceps tendon repair technique and the knotless suture-bridge repair technique both provided anatomic footprint coverage. Ultimate load to failure was highest for the V-shaped distal triceps tendon repair technique, while gap formation was different only in comparison with the transosseous cruciate repair technique. The V-shaped distal triceps tendon repair technique provides an alternative procedure to other established repairs for acute/subacute distal triceps tendon ruptures. The reduced repair site motion of the V-shaped distal triceps tendon repair technique and the knotless suture-bridge repair technique at the time of surgery may allow a more aggressive rehabilitation program in the early postoperative period.

  12. Positioning Techniques to Reduce the Occurrence of DeQuervain's Tendonitis in Nursing Mothers

    ERIC Educational Resources Information Center

    Virzi, Alison

    2010-01-01

    DeQuervain's tendonitis is an inflammation of two tendons: the extensor pollicis brevis and the abductor pollicis longus as they cross in the first dorsal compartment of the wrist. Symptoms include pain, swelling along the radial aspect of the wrist, and a decrease in thumb motion. A positive Finkelstein's test at examination is seen. Frequently…

  13. [Upright posture of man and morphologic evolution of the musculi extensores digitorum pedis with reference to evolutionary myology. III].

    PubMed

    Kaneff, A

    1986-01-01

    The following anatomical objects were studied with regard to myology during evolution: M. extensor hallucis longus (MEHL), M. extensor digitorum longus (MEDL) with M. peroneus tertius (MP III), M. peroneus brevis (MPB) with M. peroneus digiti V (MPD V), M. extensor hallucis brevis (MEHB), M. extensor digitorum brevis (MEDB), and the Retinaculum musculorum extensorum imum (RMEI). The study was carried out by the preparation of 3 different groups of material. The 1st group consists of lower extremities of humans. The number of the extremities differs for the particular objects between 151 and 358 (see page 381). The 2nd group of material consists of 122 Membra pelvina from Marsupialia, Insectivora, and Primates. Table 1 shows as well the mammalian species as the number of the studied extremities. The extremities of the 1st and 2nd group were preserved in an manner suitable for a macroscopic preparation. The 3rd group of material consists of 71 lower extremities from embryos and fetus. The lower legs and feet were stained either according to the method described by Morel and Bassal with eosin added or according to Weigert. From this material, complete series of cross sections were prepared. Table 2 shows the age of the embryos (VCL [mm]) as well as the number of the studied extremities. It is important that up to the age of 46 mm VCL the difference in the age of the embryos usually amounts from 0.5 to 1.0 mm. This small difference in the age of the embryos and fetus allows a very good follow up of the changes in construction during the organogenesis. The comparison of the 3 different groups shows the following changes for the above mentioned muscles: The M. extensor hallucis longus (MEHL) is a muscle which is not split. The same result applies for its tendon which inserts at the distal phalanx of the hallux. This primitive form of the muscle amounts actually to 51.12% in human beings. In 48.88% of the cases, additional tendons and muscles are formed by the MEHL. Most of these supplements are positioned on the medial side of the main tendon, only a few lie to the lateral side. For the supplement tendons, the medial one as well as the lateral one occasionally possess a muscle belly. The muscle of the medial tendon is split off from the proximal margin of the MEHL. The muscle of the lateral tendon is split off from the distal margin of the MEHL.(ABSTRACT TRUNCATED AT 400 WORDS)

  14. Hand Surgeon Reporting of Tendon Rupture Following Distal Radius Volar Plating

    PubMed Central

    Monaco, Nathan A.; Dwyer, C. Liam; Ferikes, Alex J.; Lubahn, John D.

    2016-01-01

    Background: Volar plate fixation with locked screws has become the preferred treatment of displaced distal radius fractures that cannot be managed nonoperatively. This treatment, however, is not without complication. The purpose of this study was to determine what percentage of hand surgeons, over a 12-month period, have experienced a tendon complication when using volar plates for the treatment of distal radius fractures. Methods: A total of 3022 hand surgeons were e-mailed a link to an online questionnaire regarding their observation and treatment of tendon injuries associated with volar plating of distal radius fractures. Responses were reported using descriptive statistics. Results: Of the 596 (20%) respondents, 199 (33%) surgeons reported encountering at least one flexor tendon injury after distal radius volar plating over the past year of practice. The flexor pollicis longus was the most commonly reported tendon injury (254, 75%). Palmaris longus grafting (118, 37%) and tendon transfer (114, 36%) were the most often reported treatments following this complication. A total of 216 respondents (36%) also encountered 324 cases of extensor tendon rupture after volar plating of distal radius fractures, with tendon transfer (88%) being the preferred treatment option. Conclusions: Both flexor and extensor tendon ruptures can be seen after volar plating of distal radius fractures. Surgeons should be aware of these complications. Critical assessment of hardware position at the time of index procedure is recommended to avoid complications. Long-term studies are needed to standardize approaches to managing tendon rupture following volar plating of distal radius fractures. PMID:27698628

  15. Hand Surgeon Reporting of Tendon Rupture Following Distal Radius Volar Plating.

    PubMed

    Monaco, Nathan A; Dwyer, C Liam; Ferikes, Alex J; Lubahn, John D

    2016-09-01

    Background: Volar plate fixation with locked screws has become the preferred treatment of displaced distal radius fractures that cannot be managed nonoperatively. This treatment, however, is not without complication. The purpose of this study was to determine what percentage of hand surgeons, over a 12-month period, have experienced a tendon complication when using volar plates for the treatment of distal radius fractures. Methods: A total of 3022 hand surgeons were e-mailed a link to an online questionnaire regarding their observation and treatment of tendon injuries associated with volar plating of distal radius fractures. Responses were reported using descriptive statistics. Results: Of the 596 (20%) respondents, 199 (33%) surgeons reported encountering at least one flexor tendon injury after distal radius volar plating over the past year of practice. The flexor pollicis longus was the most commonly reported tendon injury (254, 75%). Palmaris longus grafting (118, 37%) and tendon transfer (114, 36%) were the most often reported treatments following this complication. A total of 216 respondents (36%) also encountered 324 cases of extensor tendon rupture after volar plating of distal radius fractures, with tendon transfer (88%) being the preferred treatment option. Conclusions: Both flexor and extensor tendon ruptures can be seen after volar plating of distal radius fractures. Surgeons should be aware of these complications. Critical assessment of hardware position at the time of index procedure is recommended to avoid complications. Long-term studies are needed to standardize approaches to managing tendon rupture following volar plating of distal radius fractures.

  16. The Quadriga Effect Revisited: Designing a “Safety Incision” to Prevent Tendon Repair Rupture and Gap Formation in a Canine Model In Vitro

    PubMed Central

    Giambini, Hugo; Ikeda, Jun; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng

    2012-01-01

    Loss of experimental animals due to tendon repair failure results in the need for additional animals to complete the study. We designed a relief proximal to the flexor digitorum profundus (FDP) tendon repair site to serve as a “safety incision” to prevent repair site ruptures and maximize safety incision-to-suture strength. The FDP tendons were dissected in 24 canine forepaws. The 2nd and 5th tendons were lacerated at the proximal interphalangeal joint level and sutured using a modified Kessler technique and peripheral running suture. Tendon width was measured where the FDP tendon separates into each individual digit and a safety incision, equal to the 2nd and 5th tendon widths, was performed 3, 4, or 5 mm (Groups 1, 2, and 3) proximal to the separation. The tendons were pulled at a rate of 1 mm/s until either the “safety incision” ruptured or the repair failed. There was no gap formation at the repair site in Groups 1 and 2. However, all Group 3 tendons failed by repair site rupture with the safety incision intact. An adequate safety incision to protect repair gap and rupture and maintain tendon tension for the FDP animal model should be about 4 mm from where the FDP tendon separates. PMID:20872585

  17. An Overview of the Management of Flexor Tendon Injuries

    PubMed Central

    Griffin, M; Hindocha, S; Jordan, D; Saleh, M; Khan, W

    2012-01-01

    Flexor tendon injuries still remain a challenging condition to manage to ensure optimal outcome for the patient. Since the first flexor tendon repair was described by Kirchmayr in 1917, several approaches to flexor tendon injury have enabled successful repairs rates of 70-90%. Primary surgical repair results in better functional outcome compared to secondary repair or tendon graft surgery. Flexor tendon injury repair has been extensively researched and the literature demonstrates successful repair requires minimal gapping at the repair site or interference with tendon vascularity, secure suture knots, smooth junction of tendon end and having sufficient strength for healing. However, the exact surgical approach to achieve success being currently used among surgeons is still controversial. Therefore, this review aims to discuss the results of studies demonstrating the current knowledge regarding the optimal approach for flexor tendon repair. Post-operative rehabilitation for flexor tendon surgery is another area, which has caused extensive debate in hand surgery. The trend to more active mobilisation protocols seems to be favoured but further study in this area is needed to find the protocol, which achieves function and gliding but avoids rupture of the tendons. Lastly despite success following surgery complications commonly still occur post surgery, including adhesion formation, tendon rupture and stiffness of the joints. Therefore, this review aims to discuss the appropriate management of these difficulties post surgery. New techniques in management of flexor tendon will also be discussed including external laser devices, addition of growth factors and cytokines. PMID:22431948

  18. The intersection syndrome: Ultrasound findings and their diagnostic value

    PubMed Central

    Montechiarello, S.; Miozzi, F.; D’Ambrosio, I.; Giovagnorio, F.

    2010-01-01

    Introduction The intersection syndrome is a well-known overuse syndrome of the distal forearm. It is characterized by noninfectious, inflammatory changes involving the area of intersection of the first (abductor pollicis longus and extensor pollicis brevis) and second (extensor carpi radialis longus and extensor carpi radialis brevis) extensor compartments in the dorsoradial aspect of the distal forearm. Imaging modalities used to diagnosis this syndrome include ultrasonography (US) and magnetic resonance imaging. The purpose of this report is to describe typical US findings in the intersection syndrome and to demonstrate the diagnostic value of this approach. Materials and methods We reviewed US findings in 4 patients (mean age 40 years) referred to our staff for symptoms suggestive of the intersection syndrome (pain, swelling, erythema, and edema of the wrist). Results In all 4 cases, the US examination revealed peritendinous edema and synovial fluid within the tendon sheaths at the intersection between the first and the second dorsal extensor tendon compartments. Discussion Our experience shows that the intersection syndrome is associated with typical signs on US. This imaging modality can be considered a reliable tool for diagnosing this syndrome and may eliminate the need for other more expensive tests. PMID:23396515

  19. Distal Attachment of Flexor Tendon Allograft: A Biomechanical Study of Different Reconstruction Techniques in Human Cadaver Hands

    PubMed Central

    Wei, Zhuang; Thoreson, Andrew R.; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng

    2014-01-01

    We compared the mechanical force of tendon-to-bone repair techniques for flexor tendon reconstruction. Thirty-six flexor digitorum profundus (FDP) tendons were divided into three groups based upon the repair technique: (1) suture/button repair using FDP tendon (Pullout button group), (2) suture bony anchor using FDP tendon (Suture anchor group), and (3) suture/button repair using FDP tendon with its bony attachment preserved (Bony attachment group). The repair failure force and stiffness were measured. The mean load to failure and stiffness in the bony attachment group were significantly higher than that in the pullout button and suture anchor groups. No significant difference was found in failure force and stiffness between the pullout button and suture anchor groups. An intrasynovial flexor tendon graft with its bony attachment has significantly improved tensile properties at the distal repair site when compared with a typical tendon-to-bone attachment with a button or suture anchor. The improvement in the tensile properties at the repair site may facilitate postoperative rehabilitation and reduce the risk of graft rupture. PMID:23754507

  20. Platelet-rich plasma versus corticosteroid injection for recalcitrant lateral epicondylitis: clinical and ultrasonographic evaluation.

    PubMed

    Gautam, V K; Verma, Saurabh; Batra, Sahil; Bhatnagar, Nidhi; Arora, Sumit

    2015-04-01

    To evaluate the clinical and ultrasonographic changes in the morphology and vascularity of the common extensor tendon after injecting platelet-rich plasma (PRP) or corticosteroid (CS) for recalcitrant lateral epicondylitis (LE). 30 patients aged 18 to 60 years with recalcitrant (>6 months) LE not responsive to oral medication or non-invasive treatment were randomised to receive PRP (n=15) or CS (n=15) injection. Patients were assessed using the visual analogue scale (VAS) for pain, Disabilities of the Arm, Shoulder and Hand Scale (DASH) score, Oxford Elbow Score, modified Mayo Clinic performance index for the elbow (modified Mayo score), and hand grip strength. Ultrasonography was performed by a musculoskeletal ultrasonologist to evaluate for tear at the common extensor origin, oedema at the common extensor origin, cortical erosion, probe-induced tenderness, and thickness of the tendon. The VAS for pain, DASH score, Oxford Elbow Score, modified Mayo score, and hand grip strength all improved significantly from pre-injection to the 6-month follow-up in the PRP and CS groups. However, in the CS group, the scores generally peaked at 3 months and then deteriorated slightly at 6 months indicating recurrence of symptoms, which involved 46.7% of the CS patients. At 6 months, the number of patients positive for various ulrasonographic findings generally decreased. However, in the CS group, the number of patients with reduced thickness of the common extensor tendon increased from 2 to 12, and the number of patients with cortical erosion at the lateral epicondyle increased from 9 to 11. PRP appeared to enable biological healing of the lesion, whereas CS appeared to provide short-term, symptomatic relief but resulted in tendon degeneration.

  1. Sonographic differentiation of digital tendon rupture from adhesive scarring after primary surgical repair.

    PubMed

    Budovec, Joseph J; Sudakoff, Gary S; Dzwierzynski, William W; Matloub, Hani S; Sanger, James R

    2006-04-01

    After the surgical repair of finger tendons finger range of motion may be limited by tendon rupture or adhesive scarring. Differentiating tendon rupture from adhesive scarring may be difficult clinically. Digital tendon sonography allows the evaluation of tendon integrity in a dynamic setting. Our objective was to determine if sonography could differentiate tendon rupture from adhesive scarring in patients who have had primary tendon repair. A retrospective review was performed of the radiographic, clinical, and surgical records of patients referred for finger sonography over a 2-year period. Twenty-eight digits in 21 patients were evaluated for finger tendon disruption after primary surgical repair. The diagnosis of complete tendon rupture was made when 1 or more of the following was identified: a gap separating the proximal and distal tendon margins, visualization of only the proximal tendon margin, or visualization of only the distal tendon margin. Adhesive scarring was diagnosed if the tendon appeared intact with abnormal peritendinous soft tissue abutting or partially encasing the tendon, with synovial sheath thickening, or with restricted tendon motion during dynamic evaluation. Sonography correctly identified tendon rupture or adhesive scarring in 27 of 28 digits with 1 false-positive case (sensitivity, 100%; specificity, 93%; positive-predictive value, 93%; negative-predictive value, 100%; accuracy, 96%). Sonography is an accurate modality for differentiating tendon rupture from adhesive scarring in patients with prior surgical tendon repair. Diagnostic, Level I.

  2. Nitrous acid pretreatment of tendon xenografts cross-linked with glutaraldehyde and sterilized with gamma irradiation.

    PubMed

    Johnson, K A; Rogers, G J; Roe, S C; Howlett, C R; Clayton, M K; Milthorpe, B K; Schindhelm, K

    1999-06-01

    Collagenous xenografts made from kangaroo tail tendon cross-linked with glutaraldehyde have a potential application in the reconstruction of massive digital tendon deficits. However, a limitation to the clinical use of these xenografts has been the optimization of collagen cross-linking, and subsequent bio-incorporation and retention of mechanical properties following implantation. The purpose of this study was to evaluate the effect of nitrous acid on modulating the biologic and mechanical properties of tendon xenografts cross-linked with glutaraldehyde. Tendon xenografts were pretreated with 0.1 or 0.01 M nitrous acid solution, prior to cross-linking in 2% glutaraldehyde and sterilization by gamma irradiation. Xenografts were implanted intramuscularly in rabbits to examine biocompatability, and also used to repair ovine digital extensor tendon deficits to evaluate functional incorporation. Histologically, intramuscularly implanted nitrous acid pretreated xenografts in rabbits had a greater degree of diffuse cellular infiltration into interstitial splits in the graft than controls after 12 weeks. Xenografts implanted in an ovine extensor tendon deficit were evaluated after 26 and 52 weeks. Rate of failure of tenorrhaphies between host tendon and xenografts overall (15/21) was significantly greater (P < 0.05) than for autografts (1/21), suggesting that the holding power of sutures in xenografts was inferior to that obtained in autografts. Tensile failure stress of midsections of both nitrous acid pretreated and control xenografts was about 100 MPa prior to implantation (time zero). After 26 and 52 weeks, failure stress of both types of xenografts was significantly less than at time zero (P < 0.05). At 52 weeks, failure stress of nitrous acid pretreated xenografts (47.4 +/- 3.1 MPa) was significantly less than control xenografts (63.7 +/- 5.4 MPa); (P < 0.05). However, nitrous acid pretreated xenografts were similar to control xenografts in failure load (357 +/- 29 and 354 +/- 26 N, respectively), but they tended to have larger cross-sectional areas (7.6 +/- 0.5 versus 5.7 +/- 0.6 mm2, respectively) which were responsible for the lower calculated value for failure stress. Histologically, autografts maintained their normal tissue architecture and evoked a more limited cellular response in surrounding tissues than xenografts (P < 0.05). Both types of xenograft were surrounded by a thicker cuff of cellular response than autografts. However, compared to control xenografts, nitrous acid pretreated xenografts had more extensive fragmentation and splitting of collagen bundles, and more diffuse cellular and vascular infiltration into these interstitial splits, and these alterations were apparently contributing to the greater 'swelling' of these xenografts. It was concluded that pretreatment of tendon xenografts with nitrous acid modulated their biologic and material properties. Further studies are needed to elucidate the mechanism of these effects, and to determine if the protocol for tendon xenograft preparation could be optimized for improved clinical performance.

  3. Therapeutic Effects of Doxycycline on the Quality of Repaired and Unrepaired Achilles Tendons.

    PubMed

    Nguyen, Quynhhoa T; Norelli, Jolanta B; Graver, Adam; Ekstein, Charles; Schwartz, Johnathan; Chowdhury, Farzana; Drakos, Mark C; Grande, Daniel A; Chahine, Nadeen O

    2017-10-01

    Achilles tendon tears are devastating injuries, especially to athletes. Elevated matrix metalloproteinase (MMP) activity after a tendon injury has been associated with deterioration of the collagen network and can be inhibited with doxycycline (Doxy). Daily oral administration of Doxy will enhance the histological, molecular, and biomechanical quality of transected Achilles tendons. Additionally, suture repair will further enhance the quality of repaired tendons. Controlled laboratory study. Randomized unilateral Achilles tendon transection was performed in 288 adult male Sprague-Dawley rats. The injured tendons were either unrepaired (groups 1 and 2) or surgically repaired (groups 3 and 4). Animals from groups 2 and 4 received Doxy daily through oral gavage, and animals from groups 1 and 3 served as controls (no Doxy). Tendons were harvested at 1.5, 3, 6, and 9 weeks after the injury (n = 18 per group and time point). The quality of tendon repair was evaluated based on the histological grading score, collagen fiber orientation, gene expression, and biomechanical properties. In surgically repaired samples, Doxy enhanced the quality of tendon repair compared with no Doxy ( P = .0014). Doxy had a significant effect on collagen fiber dispersion, but not principal fiber angle. There was a significant effect of time on the gene expression of MMP-3, MMP-9 and TIMP1, and Doxy significantly decreased MMP-3 expression at 9 weeks. Doxy treatment with surgical repair increased the dynamic modulus at 6 weeks but not at 9 weeks after the injury ( P < .001). Doxy also increased the equilibrium modulus and decreased creep strain irrespective of the repair group. Doxy did not have a significant effect on the histology or biomechanics of unrepaired tendons. The findings indicate that daily oral administration of Doxy accelerated matrix remodeling and the dynamic and equilibrium biomechanics of surgically repaired Achilles tendons, although such enhancements were most evident at the 3- to 6-week time points. The inhibition of MMPs at the optimal stage of the repair process may accelerate Achilles tendon repair and improve biomechanical properties, especially when paired with surgical management.

  4. A novel remaining tendon preserving repair technique leads to improved outcomes in special rotator cuff tear patterns.

    PubMed

    Jeon, Yoon Sang; Kim, Rag Gyu; Shin, Sang-Jin

    2018-05-16

    The purpose of this study was to identify the tear pattern that could be anatomically repaired by preserving the remaining tendon on footprint and evaluate clinical outcomes of patients who underwent remaining tendon preserving cuff repair. Of 523 patients with full-thickness rotator cuff tears who underwent arthroscopic repair, 41 (7.8%) patients had repairable rotator cuff tear while preserving the remaining tendon. Among them, 31 patients were followed-up for more than 2 years, including 26 patients with posterior L-shaped tear and 5 patients with transtendinous tear patterns. Clinical outcomes were evaluated using ASES and Constant score, SANE score for patient satisfaction, and VAS for pain. MRI was taken for tendon integrity 6 months postoperatively. Of the 31 patients, 11 (35.5%) had previous injury history before rotator cuff tear, including 7 (26.9%) of the 26 patients with posterior L-shaped tear and 4 (80%) of the 5 patients with transtendinous tear. The average size of preoperative cuff tear was 17.8 ± 6.8 mm in anterior-to-posterior direction and 15.2 ± 5.1 mm in medial-to-lateral direction. ASES and Constant score, SANE score, and VAS for pain were significantly (p < 0.001) improved after remaining tendon preserving rotator cuff repair. Rotator cuff tendons of 22(84.6%) patients with posterior L-shaped tear and 4(80%) patients with transtendinous tear patterns were healed. Patients who underwent rotator cuff repair with preservation of the remaining tendon on the footprint obtained satisfactory functional outcomes. Rotator cuff tears in patients who had posterior L-shaped tear extending between supraspinatus and infraspinatus tendons or transtendinous tear pattern with substantial remaining tendon could be repaired using remaining tendon preserving repair technique. Anatomic reduction of torn cuff tendon without undue tension could be achieved using the remaining tendon preserving repair technique.

  5. Rotator Cuff Repair with a Tendon-Fibrocartilage-Bone Composite Bridging Patch

    PubMed Central

    Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R.; Qu, Jin; An, Kai-Nan; Amadio, Peter C.; Steinmann, Scott P.; Zhao, Chunfeng

    2015-01-01

    Background To compare the mechanical performance of a rotator cuff repaired with a novel tendon-fibrocartilage-bone composite bridging patch vs the traditional Mason-Allen repair in an in vitro canine model. Methods Twenty shoulders and 10 bridging patches from patellar tendon were harvested. The patches were trimmed and sliced into 2 layers. An infraspinatus tendon tear was created in each shoulder. Modified Mason-Allen sutures were used to repair the infraspinatus tendon to the greater tuberosity, with or without the bridging patch (bridging patch group and controls, respectively). Shoulders were loaded to failure under displacement control at a rate of 0.5mm/sec. Findings The ultimate tensile load was significantly higher in the bridging patch group than control (mean [SD], 365.46 [36.45] vs 272.79 [48.88] N; P<.001). Stiffness at the greater tuberosity repair site and the patch-infraspinatus tendon repair site was significantly higher than the control repair site (93.96 [27.72] vs 42.62 [17.48] N/mm P<.001; 65.94 [24.51] vs 42.62 [17.48] N/mm P=.02, respectively). Interpretation The tendon-fibrocartilage-bone composite bridging patch achieved higher ultimate tensile load and stiffness at the patch–greater tuberosity repair site compared with traditional repair in a canine model. This composite tissue transforms the traditional tendon-to-bone healing interface (with dissimilar tissues) into a pair of bone-to-bone and tendon-to-tendon interfaces, which may improve healing quality and reduce retear rate. PMID:26190097

  6. Rotator cuff repair with a tendon-fibrocartilage-bone composite bridging patch.

    PubMed

    Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R; Qu, Jin; An, Kai-Nan; Amadio, Peter C; Steinmann, Scott P; Zhao, Chunfeng

    2015-11-01

    To compare the mechanical performance of a rotator cuff repaired with a novel tendon-fibrocartilage-bone composite bridging patch vs the traditional Mason-Allen repair in an in vitro canine model. Twenty shoulders and 10 bridging patches from patellar tendon were harvested. The patches were trimmed and sliced into 2 layers. An infraspinatus tendon tear was created in each shoulder. Modified Mason-Allen sutures were used to repair the infraspinatus tendon to the greater tuberosity, with or without the bridging patch (bridging patch group and controls, respectively). Shoulders were loaded to failure under displacement control at a rate of 0.5mm/s. The ultimate tensile load was significantly higher in the bridging patch group than control (mean [SD], 365.46 [36.45] vs 272.79 [48.88] N; P<.001). Stiffness at the greater tuberosity repair site and the patch-infraspinatus tendon repair site was significantly higher than the control repair site (93.96 [27.72] vs 42.62 [17.48] N/mm P<.001; 65.94 [24.51] vs 42.62 [17.48] N/mm P=.02, respectively). The tendon-fibrocartilage-bone composite bridging patch achieved higher ultimate tensile load and stiffness at the patch-greater tuberosity repair site compared with traditional repair in a canine model. This composite tissue transforms the traditional tendon-to-bone healing interface (with dissimilar tissues) into a pair of bone-to-bone and tendon-to-tendon interfaces, which may improve healing quality and reduce retear rate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. EGR1 induces tenogenic differentiation of tendon stem cells and promotes rabbit rotator cuff repair.

    PubMed

    Tao, Xu; Liu, Junpeng; Chen, Lei; Zhou, You; Tang, Kanglai

    2015-01-01

    The rate of healing failure after surgical repair of chronic rotator cuff tears is considerably high. The aim of this study was to investigate the function of the zinc finger transcription factor early growth response 1 (EGR1) in the differentiation of tendon stem cells (TSCs) and in tendon formation, healing, and tendon tear repair using an animal model of rotator cuff repair. Tenocyte, adipocyte, osteocyte, and chondrocyte differentiation as well as the expression of related genes were determined in EGR1-overexpressing TSCs (EGR1-TSCs) using tissue-specific staining, immunofluorescence staining, quantitative PCR, and western blotting. A rabbit rotator cuff repair model was established, and TSCs and EGR1-TSCs in a fibrin glue carrier were applied onto repair sites. The rabbits were sacrificed 8 weeks after repair operation, and tissues were histologically evaluated and tenocyte-related gene expression was determined. EGR1 induced tenogenic differentiation of TSCs and inhibited non-tenocyte differentiation of TSCs. Furthermore, EGR1 promoted tendon repair in a rabbit model of rotator cuff injury. The BMP12/Smad1/5/8 signaling pathway was involved in EGR1-induced tenogenic differentiation and rotator cuff tendon repair. EGR1 plays a key role in tendon formation, healing, and repair through BMP12/Smad1/5/8 pathway. EGR1-TSCs is a promising treatment for rotator cuff tendon repair surgeries. © 2015 S. Karger AG, Basel.

  8. Unifying principles in terrestrial locomotion: do hopping Australian marsupials fit in?

    PubMed

    Bennett, M B

    2000-01-01

    Mammalian terrestrial locomotion has many unifying principles. However, the Macropodoidea are a particularly interesting group that exhibit a number of significant deviations from the principles that seem to apply to other mammals. While the properties of materials that comprise the musculoskeletal system of mammals are similar, evidence suggests that tendon properties in macropodoid marsupials may be size or function dependent, in contrast to the situation in placental mammals. Postural differences related to hopping versus running have a dramatic effect on the scaling of the pelvic limb musculoskeletal system. Ratios of muscle fibre to tendon cross-sectional areas for ankle extensors and digital flexors scale with positive allometry in all mammals, but exponents are significantly higher in macropods. Tendon safety factors decline with increasing body mass in mammals, with eutherians at risk of ankle extensor tendon rupture at a body mass of about 150 kg, whereas kangaroos encounter similar problems at a body mass of approximately 35 kg. Tendon strength appears to limit locomotor performance in these animals. Elastic strain energy storage in tendons is mass dependent in all mammals, but exponents are significantly larger in macropodid. Tibial stresses may scale with positive allometry in kangaroos, which result in lower bone safety factors in macropods compared to eutherian mammals.

  9. Etiology, Diagnosis and Treatment of Tendinous Knee Extensor Mechanism Injuries.

    PubMed

    Ibounig, T; Simons, T A

    2016-06-01

    Quadriceps and patella tendon ruptures are uncommon injuries often resulting from minor trauma typically consisting of an eccentric contraction of the quadriceps muscle. Since rupture of a healthy tendon is very rare, such injuries usually represent the end stage of a long process of chronic tendon degeneration and overuse. This review aims to give an overview of the current understanding of the pathophysiology, diagnostic principles, and recommended treatment protocols as supported by the literature and institutional experience. A non-systematic review of the current literature on the subject was conducted and reflected against the current practice in our level 1 trauma center. Risk factors for patella and quadriceps tendon rupture include increasing age, repetitive micro-trauma, genetic predisposition, and systemic diseases, as well as certain medications. Diagnosis is based on history and clinical findings, but can be complemented by ultrasound or magnetic resonance imaging. Accurate diagnosis at an early stage is of utmost importance since delay in surgical repair of over 3 weeks results in significantly poorer outcomes. Operative treatment of acute ruptures yields good clinical results with low complication rates. Use of longitudinal transpatellar drill holes is the operative method of choice in the majority of acute cases. In chronic ruptures, tendon augmentation with auto- or allograft should be considered. Postoperative treatment protocols in the literature range from early mobilization with full weight bearing to cast immobilization for up to 12 weeks. Respecting the biology of tendon healing, we advocate the use of a removable knee splint or orthotic with protected full weight bearing and limited passive mobilization for 6 weeks. © The Finnish Surgical Society 2015.

  10. The Role of Mechanical Loading in Tendon Development, Maintenance, Injury, and Repair

    PubMed Central

    Galloway, Marc T.; Lalley, Andrea L.; Shearn, Jason T.

    2013-01-01

    ➤ Tendon injuries often result from excessive or insufficient mechanical loading, impairing the ability of the local tendon cell population to maintain normal tendon function. ➤ The resident cell population composing tendon tissue is mechanosensitive, given that the cells are able to alter the extracellular matrix in response to modifications of the local loading environment. ➤ Natural tendon healing is insufficient, characterized by improper collagen fibril diameter formation, collagen fibril distribution, and overall fibril misalignment. ➤ Current tendon repair rehabilitation protocols focus on implementing early, well-controlled eccentric loading exercises to improve repair outcome. ➤ Tissue engineers look toward incorporating mechanical loading regimens to precondition cell populations for the creation of improved biological augmentations for tendon repair. PMID:24005204

  11. Tendon-Holding Capacities of Two Newly Designed Implants for Tendon Repair: An Experimental Study on the Flexor Digitorum Profundus Tendon of Sheep

    PubMed Central

    Ağır, İsmail; Aytekin, Mahmut Nedim; Başçı, Onur; Çaypınar, Barış; Erol, Bülent

    2014-01-01

    Background: Two main factors determine the strength of tendon repair; the tensile strength of material and the gripping capacity of a suture configuration. Different repair techniques and suture materials were developed to increase the strength of repairs but none of techniques and suture materials seem to provide enough tensile strength with safety margins for early active mobilization. In order to overcome this problem tendon suturing implants are being developed. We designed two different suturing implants. The aim of this study was to measure tendon-holding capacities of these implants biomechanically and to compare them with frequently used suture techniques Materials and Methods: In this study we used 64 sheep flexor digitorum profundus tendons. Four study groups were formed and each group had 16 tendons. We applied model 1 and model 2 implant to the first 2 groups and Bunnell and locking-loop techniques to the 3rd and 4th groups respectively by using 5 Ticron sutures. Results: In 13 tendons in group 1 and 15 tendons in group 2 and in all tendons in group 3 and 4, implants and sutures pulled out of the tendon in longitudinal axis at the point of maximum load. The mean tensile strengths were the largest in group 1 and smallest in group 3. Conclusion: In conclusion, the new stainless steel tendon suturing implants applied from outside the tendons using steel wires enable a biomechanically stronger repair with less tendon trauma when compared to previously developed tendon repair implants and the traditional suturing techniques. PMID:25067965

  12. Enhanced tendon-to-bone repair through adhesive films.

    PubMed

    Linderman, Stephen W; Golman, Mikhail; Gardner, Thomas R; Birman, Victor; Levine, William N; Genin, Guy M; Thomopoulos, Stavros

    2018-04-01

    Tendon-to-bone surgical repairs have unacceptably high failure rates, possibly due to their inability to recreate the load transfer mechanisms of the native enthesis. Instead of distributing load across a wide attachment footprint area, surgical repairs concentrate shear stress on a small number of suture anchor points. This motivates development of technologies that distribute shear stresses away from suture anchors and across the enthesis footprint. Here, we present predictions and proof-of-concept experiments showing that mechanically-optimized adhesive films can mimic the natural load transfer mechanisms of the healthy attachment and increase the load tolerance of a repair. Mechanical optimization, based upon a shear lag model corroborated by a finite element analysis, revealed that adhesives with relatively high strength and low stiffness can, theoretically, strengthen tendon-to-bone repairs by over 10-fold. Lap shear testing using tendon and bone planks validated the mechanical models for a range of adhesive stiffnesses and strengths. Ex vivo human supraspinatus repairs of cadaveric tissues using multipartite adhesives showed substantial increase in strength. Results suggest that adhesive-enhanced repair can improve repair strength, and motivate a search for optimal adhesives. Current surgical techniques for tendon-to-bone repair have unacceptably high failure rates, indicating that the initial repair strength is insufficient to prevent gapping or rupture. In the rotator cuff, repair techniques apply compression over the repair interface to achieve contact healing between tendon and bone, but transfer almost all force in shear across only a few points where sutures puncture the tendon. Therefore, we evaluated the ability of an adhesive film, implanted between tendon and bone, to enhance repair strength and minimize the likelihood of rupture. Mechanical models demonstrated that optimally designed adhesives would improve repair strength by over 10-fold. Experiments using idealized and clinically-relevant repairs validated these models. This work demonstrates an opportunity to dramatically improve tendon-to-bone repair strength using adhesive films with appropriate material properties. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  13. [Experimental study of tendon graft fixation in anterior cruciate ligament reconstruction with cortical press-fit bolt in rabbits].

    PubMed

    Qi, Wei; Li, Chun-bao; Wang, Jun-liang; Zhu, Juan-li; Liu, Yu-jie

    2013-05-21

    To explore the histological outcomes of tendon-bone healing in anterior cruciate ligament (ACL) reconstruction with cortical press-fit bolt (CPB). Twenty-four healthy female or male New Zealand White rabbits (2-3 months old) underwent bilateral ACL reconstruction with extensor digitorum longus tendon. A random method was used to decide one knee would receive the routine ACL reconstruction (control group) and another cortical press-fit bolt fixation (experimental group). After general anesthesia, extensor digitorum longus tendon was harvested and ACL reconstruction performed. All animals were sacrificed at 4, 8 and 12 weeks postoperation. Radiological and histological examinations were made at each timepoint. The specimens were stained with different methods to observe the pathological changes of tendon graft, bone tunnel and cortical press-fit bolt. More revascularization and massive new bone were found in tendon-bone junction of experimental group at 4, 8 and 12 weeks postoperation. The circum-graft new vessel proportion of the experimental and control groups were 0.48 ± 0.12 and 0.26 ± 0.05 respectively (P < 0.05). In the experimental group, more cartilage cells were present in tendon-bone junction at 12 weeks and the circum-graft new bone areas in two groups were 0.41 ± 0.11 and 0.21 ± 0.10 mm(2) respectively (P < 0.05). Cortical press-fit blot may improve tendon-bone healing after ACL reconstruction in rabbits. The application prospects of this procedure are promising.

  14. Transcription factor EGR1 directs tendon differentiation and promotes tendon repair

    PubMed Central

    Guerquin, Marie-Justine; Charvet, Benjamin; Nourissat, Geoffroy; Havis, Emmanuelle; Ronsin, Olivier; Bonnin, Marie-Ange; Ruggiu, Mathilde; Olivera-Martinez, Isabel; Robert, Nicolas; Lu, Yinhui; Kadler, Karl E.; Baumberger, Tristan; Doursounian, Levon; Berenbaum, Francis; Duprez, Delphine

    2013-01-01

    Tendon formation and repair rely on specific combinations of transcription factors, growth factors, and mechanical parameters that regulate the production and spatial organization of type I collagen. Here, we investigated the function of the zinc finger transcription factor EGR1 in tendon formation, healing, and repair using rodent animal models and mesenchymal stem cells (MSCs). Adult tendons of Egr1–/– mice displayed a deficiency in the expression of tendon genes, including Scx, Col1a1, and Col1a2, and were mechanically weaker compared with their WT littermates. EGR1 was recruited to the Col1a1 and Col2a1 promoters in postnatal mouse tendons in vivo. Egr1 was required for the normal gene response following tendon injury in a mouse model of Achilles tendon healing. Forced Egr1 expression programmed MSCs toward the tendon lineage and promoted the formation of in vitro–engineered tendons from MSCs. The application of EGR1-producing MSCs increased the formation of tendon-like tissues in a rat model of Achilles tendon injury. We provide evidence that the ability of EGR1 to promote tendon differentiation is partially mediated by TGF-β2. This study demonstrates EGR1 involvement in adult tendon formation, healing, and repair and identifies Egr1 as a putative target in tendon repair strategies. PMID:23863709

  15. Extensor tendinopathy of the elbow assessed with sonoelastography: histologic correlation.

    PubMed

    Klauser, Andrea S; Pamminger, Mathias; Halpern, Ethan J; Abd Ellah, Mohamed M H; Moriggl, Bernhard; Taljanovic, Mihra S; Deml, Christian; Sztankay, Judit; Klima, Guenther; Jaschke, Werner R

    2017-08-01

    To compare agreement between conventional B-mode ultrasound (US) and compression sonoelastography (SEL) of the common extensor tendons of the elbow with histological evaluation. Twenty-six common extensor tendons were evaluated in 17 cadavers (11 females, median age 85 years and 6 males, median age 80 years). B-mode US was graded into: Grade 1, homogeneous fibrillar pattern; grade 2, hypoechoic areas and/or calcifications <30%; and grade 3 > 30%. SEL was graded into: Grade 1 indicated blue (hardest) to green (hard); grade 2 yellow (soft); and grade 3 red (softest). B-mode US, SEL, and a combined grading score incorporating both were compared to histological findings in 76 biopsies. Histological alterations were detected in 55/76 biopsies. Both modalities showed similar results (sensitivity, specificity, and accuracy 84%, 81%, and 83% for B-mode US versus 85%, 86%, and 86% for SEL, respectively, P > 0.3). However, a combination of both resulted in significant improvement in sensitivity (96%, P < 0.02) without significant change in specificity (81%, P < 0.3), yielding an improved overall accuracy (92%). Combined imaging of the extensor tendons with both modalities is superior to either modality alone for predicting the presence of pathologic findings on histology. • Combination of B-mode US and SEL proved efficiency in diagnosing lateral epicondylitis. • Combination of B-mode US and SEL in lateral epicondylitis correlates to histology. • Combination of both modalities provides improved sensitivity without loss of specificity.

  16. Functional tissue engineering of tendon: Establishing biological success criteria for improving tendon repair.

    PubMed

    Breidenbach, Andrew P; Gilday, Steven D; Lalley, Andrea L; Dyment, Nathaniel A; Gooch, Cynthia; Shearn, Jason T; Butler, David L

    2014-06-27

    Improving tendon repair using Functional Tissue Engineering (FTE) principles has been the focus of our laboratory over the last decade. Although our primary goals were initially focused only on mechanical outcomes, we are now carefully assessing the biological properties of our tissue-engineered tendon repairs so as to link biological influences with mechanics. However, given the complexities of tendon development and healing, it remains challenging to determine which aspects of tendon biology are the most important to focus on in the context of tissue engineering. To address this problem, we have formalized a strategy to identify, prioritize, and evaluate potential biological success criteria for tendon repair. We have defined numerous biological properties of normal tendon relative to cellular phenotype, extracellular matrix and tissue ultra-structure that we would like to reproduce in our tissue-engineered repairs and prioritized these biological criteria by examining their relative importance during both normal development and natural tendon healing. Here, we propose three specific biological criteria which we believe are essential for normal tendon function: (1) scleraxis-expressing cells; (2) well-organized and axially-aligned collagen fibrils having bimodal diameter distribution; and (3) a specialized tendon-to-bone insertion site. Moving forward, these biological success criteria will be used in conjunction with our already established mechanical success criteria to evaluate the effectiveness of our tissue-engineered tendon repairs. © 2013 Published by Elsevier Ltd.

  17. Effect of Implanting a Soft Tissue Autograft in a Central-Third Patellar Tendon Defect: Biomechanical and Histological Comparisons

    PubMed Central

    Kinneberg, Kirsten R. C.; Galloway, Marc T.; Butler, David L.; Shearn, Jason T.

    2011-01-01

    Previous studies by our laboratory have demonstrated that implanting a stiffer tissue engineered construct at surgery is positively correlated with repair tissue stiffness at 12 weeks. The objective of this study was to test this correlation by implanting a construct that matches normal tissue biomechanical properties. To do this, we utilized a soft tissue patellar tendon autograft to repair a central-third patellar tendon defect. Patellar tendon auto-graft repairs were contrasted against an unfilled defect repaired by natural healing (NH). We hypothesized that after 12 weeks, patellar tendon autograft repairs would have biomechanical properties superior to NH. Bilateral defects were established in the central-third patellar tendon of skeletally mature (one year old), female New Zealand White rabbits (n = 10). In one limb, the excised tissue, the patellar tendon autograft, was sutured into the defect site. In the contralateral limb, the defect was left empty (natural healing). After 12 weeks of recovery, the animals were euthanized and their limbs were dedicated to bio-mechanical (n = 7) or histological (n = 3) evaluations. Only stiffness was improved by treatment with patellar tendon autograft relative to natural healing (p = 0.009). Additionally, neither the patellar tendon autograft nor natural healing repairs regenerated a normal zonal insertion site between the tendon and bone. Immunohistochemical staining for collagen type II demonstrated that fibrocartilage-like tissue was regenerated at the tendon-bone interface for both repairs. However, the tissue was disorganized. Insufficient tissue integration at the tendon-to-bone junction led to repair tissue failure at the insertion site during testing. It is important to re-establish the tendon-to-bone insertion site because it provides joint stability and enables force transmission from muscle to tendon and subsequent loading of the tendon. Without loading, tendon mechanical properties deteriorate. Future studies by our laboratory will investigate potential strategies to improve patellar tendon autograft integration into bone using this model. [DOI: 10.1115/1.4004948] PMID:22010737

  18. Gap junction protein expression and cellularity: comparison of immature and adult equine digital tendons

    PubMed Central

    Stanley, Rachael L; Fleck, Roland A; Becker, David L; Goodship, Allen E; Ralphs, Jim R; Patterson-Kane, Janet C

    2007-01-01

    Injury to the energy-storing superficial digital flexor tendon is common in equine athletes and is age-related. Tenocytes in the superficial digital flexor tendon of adult horses appear to have limited ability to respond adaptively to exercise or prevent the accumulation of strain-induced microdamage. It has been suggested that conditioning exercise should be introduced during the growth period, when tenocytes may be more responsive to increased quantities or intensities of mechanical strain. Tenocytes are linked into networks by gap junctions that allow coordination of synthetic activity and facilitate strain-induced collagen synthesis. We hypothesised that there are reductions in cellular expression of the gap junction proteins connexin (Cx) 43 and 32 during maturation and ageing of the superficial digital flexor tendon that do not occur in the non-injury-prone common digital extensor tendon. Cryosections from the superficial digital flexor tendon and common digital extensor tendon of 5 fetuses, 5 foals (1–6 months), 5 young adults (2–7 years) and 5 old horses (18–33 years) were immunofluorescently labelled and quantitative confocal laser microscopy was performed. Expression of Cx43 and Cx32 protein per tenocyte was significantly higher in the fetal group compared with all other age groups in both tendons. The density of tenocytes was found to be highest in immature tissue. Higher levels of cellularity and connexin protein expression in immature tendons are likely to relate to requirements for tissue remodelling and growth. However, if further studies demonstrate that this correlates with greater gap junctional communication efficiency and synthetic responsiveness to mechanical strain in immature compared with adult tendons, it could support the concept of early introduction of controlled exercise as a means of increasing resistance to later injury. PMID:17848160

  19. Knotted versus knotless suture bridge repair of the achilles tendon insertion: a biomechanical study.

    PubMed

    Cox, Joseph T; Shorten, Peter L; Gould, Gregory C; Markert, Ronald J; Barnett, Michael D; Laughlin, Richard T

    2014-11-01

    Surgical treatment of insertional Achilles tendinopathy often involves detachment and debridement of the Achilles tendon insertion. A recent study has shown that knotted suture bridge fixation of the Achilles to the calcaneus is biomechanically superior to single-row fixation, but there is an absence of literature on the use of different suture bridge constructs to repair the Achilles tendon. There will be no significant difference in the load to failure, mode of failure, tendon strain, tendon stiffness, repair site gapping, or footprint size when comparing knotted suture bridge repair to knotless suture bridge repair of the Achilles tendon after detachment for insertional Achilles tendinopathy. Controlled laboratory study. A single specimen from each pair of 10 cadaveric Achilles tendons was randomized to 1 of 2 Achilles insertion repair groups: knotted (n = 10) or knotless (n = 10) suture bridge repair. Repaired footprint size was measured, and then cyclic testing from 10 to 100 N for 2000 cycles was performed. This was followed by measurement of tendon strain, repair site displacement, load to failure, and tendon stiffness. The knotted suture bridge repair had a significantly higher load to failure compared with the knotless suture bridge (mean ± SD, 317.8 ± 93.6 N vs 196.1 ± 12.1 N, respectively; P = .001). All constructs failed at the tendon-suture interface. Tendon strain after cyclic testing was significantly greater in the knotless (1.20 ± 1.05) compared with the knotted (0.39 ± 0.4) suture repair groups (P = .011). There was no significant difference in footprint size between the knotted (230.3 ± 63.3 mm(2)) and knotless (248.5 ± 48.8 mm(2)) groups (P = .40). There was also no significant difference in stiffness (knotted = 76.4 ± 8.0 N/mm; knotless = 69.6 ± 10.9 N/mm; P = .17) and repair site displacement after cyclic testing (knotted = 2.8 ± 1.2 mm; knotless = 3.6 ± 1.1 mm; P = .17). During suture bridge repair of the Achilles tendon after detachment, knots at the proximal suture anchors significantly improve the biomechanical strength of the repair. This study demonstrated that the knotless suture bridge repair had a significantly lower load to failure than the knotted suture bridge. Surgeons should be aware of these biomechanical differences, as they influence the postoperative rehabilitation protocol and may lead to higher surgical complication rates. © 2014 The Author(s).

  20. Treatment of mallet finger deformity with a modified palmaris longus tendon graft through a bone tunnel.

    PubMed

    Liu, Zengbing; Ma, Kai; Huang, Dong

    2018-01-01

    To investigate the clinical effect of treating mallet finger deformity using a modified palmaris longus tendon graft through a bone tunnel. Altogether, 21 patients with mallet finger deformity (16 men, 5 women; average age 31 years, range 19-47 years) were treated with a modified palmaris longus tendon graft through a bone tunnel during 18 months (2014-2016). Four index fingers, seven middle fingers, eight ring fingers, and two little fingers were treated for four cutting injuries, eleven finger sprains, four crush injuries, and two twist injuries (7 open and 14 closed injuries). Duration from injury to surgery was 9 h to 13 weeks. Three patients underwent surgery after 6 weeks of unsuccessful conservative treatment. No tendon was attached to the extensor tendon insertion in 16 patients, and 5 had residual tendon of <0.2 cm attached. All patients had distal segment flexion deformity and dorsiflexion disorder. Surgery comprised transverse penetration and vertical drilling of the base of the distal phalanx (2.0 and 2.5 mm diameter drills). Equal shallow semitendinosus pieces of the palmaris longus tendon (4 cm) were obtained from the sagittal end and were passed through a dorsal bone hole, emerging from a transverse bone hole. The two bundles were sutured to the main tendon. Tension was adjusted, and the broken ends were sutured. The distal interphalangeal joints were fixed in hyperextension. All patients were followed for 7-16 months (average 6.0 ± 0.3 months) postoperatively. All 21 patients had grade A wound healing, with no complications (e.g., necrotic wound, recurrence, joint stiffness). The mallet finger deformity was corrected with good appearance, no obvious abnormalities, and satisfactory flexion and extension. Two patients had a superficial wound infection. Each recovered after symptomatic treatment. One patient had a mild result, with limited extension. There were no recurrences. Results were evaluated according to Patel et al.'s system, which revealed 15 excellent and 5 good results (combined 95.23% rate), with 1 mild result (limited extension). Patients were satisfied with the appearance and function of the affected fingers, and the desired surgical end result was achieved. Use of this modified surgery for treating mallet finger deformity, especially with no or little tendon attached at the extensor tendon insertion, results in nearly anatomical reconstruction of the extensor tendon insertion. Its advantages include simple surgery, reliable fixation, fewer complications, and clinical efficacy.

  1. Observation of tendon repair in animal model using second-harmonic-generation microscopy

    NASA Astrophysics Data System (ADS)

    Hase, Eiji; Minamikawa, Takeo; Sato, Katsuya; Takahashi, Mitsuhiko; Yasui, Takashi

    2016-03-01

    Tendon rupture is a trauma difficult to recover the condition before injury. In previous researches, tensile test and staining method have been widely used to elucidate the mechanism of the repair process from the viewpoints of the mechanical property and the histological findings. However, since both methods are destructive and invasive, it is difficult to obtain both of them for the same sample. If both the mechanical property and the histological findings can be obtained from the same sample, one may obtain new findings regarding mechanisms of tendon repairing process. In this paper, we used second-harmonic-generation (SHG) microscopy, showing high selectivity and good image contrast to collagen molecules as well as high spatial resolution, optical three-dimensional sectioning, deep penetration, and without additional staining. Since SHG light intensity sensitively reflects the structural maturity of collagen molecule and its aggregates, it will be a good indicator for the repairing degree of the ruptured tendon. From comparison of SHG images between the 4-weeks-repaired tendon and the sound tendon in the animal model, we confirmed that SHG light intensity of the repaired tendon was significantly lower than that of the sound tendon, indicating that the collagen structure in the repaired tendon is still immature. Furthermore, we performed both SHG imaging and the tensile test for the same sample, and confirmed a correlation between them. This result shows a potential of SHG light for an indicator of the histological and mechanical recovery of the ruptured tendon.

  2. Slab fractures of the third tarsal bone: Minimally invasive repair using a single 3.5 mm cortex screw placed in lag fashion in 17 Thoroughbred racehorses.

    PubMed

    Barker, W H J; Wright, I M

    2017-03-01

    A technique for minimally invasive repair of slab fractures of the third tarsal bone has not previously been reported. Results of third tarsal bone slab fracture repair in Thoroughbred racehorses are lacking. To report the outcomes of repair of uniplanar frontal slab factures of the third tarsal bone using a single 3.5 mm cortex screw in lag fashion. Retrospective case series. Case records of horses that had undergone this procedure were reviewed. Seventeen horses underwent surgery. Eighteen percent of cases had wedge shaped third tarsal bones. A point midway between the long and lateral digital extensor tendons and centrodistal and tarsometatarsal joints created a suitable entry site for implants. The fracture location, configuration and curvature of the third tarsal bone and associated joints requires a dorsolateral proximal-plantaromedial distal trajectory for the screw, which was determined by preplaced needles. There were no complications and fractures healed in all cases at 4-6 months post surgery. Seventy-nine percent of horses returned to racing and, at the time of reporting, 3 are in post operative rehabilitation programmes. The technique reported provides a safe, appropriate and repeatable means of repairing slab fractures of the third tarsal bone. Surgical repair is a viable alternative to conservative management. © 2016 EVJ Ltd.

  3. Evaluating adhesion reduction efficacy of type I/III collagen membrane and collagen-GAG resorbable matrix in primary flexor tendon repair in a chicken model.

    PubMed

    Turner, John B; Corazzini, Rubina L; Butler, Timothy J; Garlick, David S; Rinker, Brian D

    2015-09-01

    Reduction of peritendinous adhesions after injury and repair has been the subject of extensive prior investigation. The application of a circumferential barrier at the repair site may limit the quantity of peritendinous adhesions while preserving the tendon's innate ability to heal. The authors compare the effectiveness of a type I/III collagen membrane and a collagen-glycosaminoglycan (GAG) resorbable matrix in reducing tendon adhesions in an experimental chicken model of a "zone II" tendon laceration and repair. In Leghorn chickens, flexor tendons were sharply divided using a scalpel and underwent repair in a standard fashion (54 total repairs). The sites were treated with a type I/III collagen membrane, collagen-GAG resorbable matrix, or saline in a randomized fashion. After 3 weeks, qualitative and semiquantitative histological analysis was performed to evaluate the "extent of peritendinous adhesions" and "nature of tendon healing." The data was evaluated with chi-square analysis and unpaired Student's t test. For both collagen materials, there was a statistically significant improvement in the degree of both extent of peritendinous adhesions and nature of tendon healing relative to the control group. There was no significant difference seen between the two materials. There was one tendon rupture observed in each treatment group. Surgical handling characteristics were subjectively favored for type I/III collagen membrane over the collagen-GAG resorbable matrix. The ideal method of reducing clinically significant tendon adhesions after injury remains elusive. Both materials in this study demonstrate promise in reducing tendon adhesions after flexor tendon repair without impeding tendon healing in this model.

  4. Is the Dresden technique a mechanical design of choice suitable for the repair of middle third Achilles tendon ruptures? A biomechanical study.

    PubMed

    de la Fuente, C; Carreño-Zillmann, G; Marambio, H; Henríquez, H

    2016-01-01

    To compare the mechanical failure of the Dresden technique for Achilles tendon repair with the double modified Kessler technique controlled repair technique. The maximum resistance of the two repair techniques are also compared. A total of 30 Achilles tendon ruptures in bovine specimens were repaired with an Ethibond(®) suture to 4.5cm from the calcaneal insertion. Each rupture was randomly distributed into one of two surgical groups. After repair, each specimen was subjected to a maximum traction test. The mechanical failure (tendon, suture, or knot) rates (proportions) were compared using the exact Fisher test (α=.05), and the maximum resistances using the Student t test (α=.05). There was a difference in the proportions of mechanical failures, with the most frequent being a tendon tear in the Dresden technique, and a rupture of the suture in the Kessler technique. The repair using the Dresden technique performed in the open mode, compared to the Kessler technique, has a more suitable mechanical design for the repair of middle third Achilles tendon ruptures on developing a higher tensile resistance in 58.7%. However, its most common mechanical failure was a tendon tear, which due to inappropriate loads could lead to lengthening of the Achilles tendon. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. FUNCTIONAL PERFORMANCE AND KNEE LAXITY IN NORMAL INDIVIDUALS AND IN INDIVIDUALS SUBMITTED TO ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

    PubMed Central

    de Vasconcelos, Rodrigo Antunes; Bevilaqua-Grossi, Débora; Shimano, Antonio Carlos; Jansen Paccola, Cleber Antonio; Salvini, Tânia Fátima; Prado, Christiane Lanatovits; Mello Junior, Wilson A.

    2015-01-01

    The aim of this study was to analyze the correlation between deficits in the isokinetic peak torque of the knee extensors and flexors with hop tests, postoperative knee laxity and functional scores in normal and ACL- reconstructed subjects with patellar tendon and hamstring tendon autografts. Methods: Sixty male subjects were enrolled and subdivided into three groups: Twenty subjects without knee injuries (GC group) and two groups of 20 subjects submitted to ACL reconstruction with patellar tendon (GTP group) and hamstrings autograft (GTF group). Results: The results showed significant correlation between knee extensors peak torque and performance in the hop tests for GTF and GC groups. There are no significantly correlations between post op knee laxity and Lysholm score compared with the hop tests and peak torque deficits. Concerning the differences between groups, the GTP group showed greater peak torque deficits in knee extensors, worst Lysholm scores and higher percentage of individuals with lower limb symmetry index (ISM) < 90% in both hop tests when compared to the other two groups. Conclusion: It is not recommendable to use only one measurement instrument for the functional evaluation of ACL-reconstructed patients, because significant correlation between peak torque, subject's functional score, knee laxity and hop tests were not observed in all groups. PMID:26998464

  6. Augmented Versus Nonaugmented Repair of Acute Achilles Tendon Rupture: A Systematic Review and Meta-analysis.

    PubMed

    Zhang, Yi-Jun; Zhang, Chi; Wang, Quan; Lin, Xiang-Jin

    2018-06-01

    Although simple end-to-end repair of the Achilles tendon is common, many augmented repair protocols have been implemented for acute Achilles tendon rupture. However, whether augmented repair is better than nonaugmented repair of an acute Achilles tendon rupture is still unknown. To conduct a meta-analysis to determine whether augmented surgical repair of an acute Achilles tendon rupture improved subjective patient satisfaction without an increase in rerupture rates. Secondary outcomes assessed included infections, ankle range of motion, calf muscle strength, and minor complications. Meta-analysis. A systematic literature search of peer-reviewed articles was conducted to identify all randomized controlled trials (RCTs) comparing augmented repair and nonaugmented repair for acute Achilles tendon rupture from January 1980 to August 2016 in the electronic databases of PubMed, Web of Science (SCI-E/SSCI/A&HCI), and EMBASE. The keywords (Achilles tendon rupture) AND (surg* OR operat* OR repair* OR augment* OR non-augment* OR end-to-end OR sutur*) were combined, and results were limited to human RCTs and controlled clinical trials published in the English language. Four RCTs involving 169 participants were eligible for inclusion; 83 participants were treated with augmented repair and 86 were treated with nonaugmented repair. Augmented repair led to similar responses when compared with nonaugmented repair for acute Achilles tendon rupture (93% vs 90%, respectively; P = .53). The rerupture rates showed no significant difference for augmented versus nonaugmented repair (7.2% vs 9.3%, respectively; P = .69). No differences in superficial and deep infections occurred in augmented (7 infections) and nonaugmented (8 infections) repair groups during postoperative follow-up ( P = .89). The average incisional infection rate was 8.4% with augmented repair and 9.3% with nonaugmented repair. No significant differences in other complications were found between augmented (7.2%) and nonaugmented (8.1%) repair ( P = .80). Augmented repair, when compared with nonaugmented repair, was not found to improve patient satisfaction or reduce rerupture rate or infection rate. These conclusions are based on 4 trials with small sample sizes, and larger randomized trials are required to confirm these results.

  7. A novel biodegradable PCL film for tendon reconstruction: Achilles tendon defect model in rats.

    PubMed

    Kazimoğlu, C; Bölükbaşi, S; Kanatli, U; Senköylü, A; Altun, N S; Babaç, C; Yavuz, H; Pişkin, E

    2003-09-01

    This study aims to investigate applicability of poly(epsilon-caprolactone) (PCL) biodegradable films for repair of gaps in Achilles tendons in a rat model, also comparing surgical repair versus no repair approaches. PCL was synthesized with tailor-made properties, then, PCL films were prepared by solvent casting. Seventy-five outbred Sprague-Dawley rats were randomly allocated into five groups: (i) sham operated (skin incision only); (ii) no repair (complete division of the Achilles tendon and plantaris tendon without repair); (iii) Achilles repair (with a modified Kessler type suture); and (iv) plasty of Achilles tendon defects with the biodegradable PCL films, and (v) animals subjected to 1 cm mid-substance defect with no repair. Functional performance was determined from the measurements of hindpaw prints utilizing the Achilles functional index. The animals were killed 8 weeks after surgery and histological and biomechanical evaluations were made. All groups subjected to Achilles tendon division had a significant functional impairment that gradually improved so that by day 28 there were no functional impairments in any group whereas animals with a defect remained impaired. The magnitude of the biomechanical and morphological changes at postoperative 8 weeks were similar for no repair group (conservative), Achilles repair group and tendonplasty group (biodegradable PCL film group). The initial rate of functional recovery was significantly different for primary suture, Achilles repair group and PCL film group (p>0.01). But, at the 28th day, functional recovery was quite similar to the other groups. In summary, our results suggest that the PCL film can be an alternative biomaterial for tendon replacement.

  8. Lubricin Surface Modification Improves Tendon Gliding After Tendon Repair in a Canine Model in Vitro

    PubMed Central

    Taguchi, Manabu; Sun, Yu-Long; Zhao, Chunfeng; Zobitz, Mark E.; Cha, Chung-Ja; Jay, Gregory D.; An, Kai-Nan; Amadio, Peter C.

    2011-01-01

    This study investigated the effects of lubricin on the gliding of repaired flexor digitorum profundus (FDP) tendons in vitro. Canine FDP tendons were completely lacerated, repaired with a modified Pennington technique, and treated with one of the following solutions: saline, carbodiimide derivatized gelatin/hyaluronic acid (cd-HA-gelatin), carbodiimide derivatized gelatin to which lubricin was added in a second step (cd-gelatin + lubricin), or carbodiimide derivatized gelatin/HA + lubricin (cd-HA-gelatin + lubricin). After treatment, gliding resistance was measured up to 1,000 cycles of simulated flexion/extension motion. The increase in average and peak gliding resistance in cd-HA-gelatin, cd-gelatin + lubricin, and cd-HA-gelatin + lubricin tendons was less than the control tendons after 1,000 cycles (p < 0.05). The increase in average gliding resistance of cd-HA-gelatin + lubricin treated tendons was also less than that of the cd-HA-gelatin treated tendons (p < 0.05). The surfaces of the repaired tendons and associated pulleys were assessed qualitatively with scanning electron microscopy and appeared smooth after 1,000 cycles of tendon motion for the cd-HA-gelatin, cd-gelatin + lubricin, and cd-HA-gelatin + lubricin treated tendons, while that of the saline control appeared roughened. These results suggest that tendon surface modification can improve tendon gliding ability, with a trend suggesting that lubricin fixed on the repaired tendon may provide additional improvement over that provided by HA and gelatin alone. PMID:18683890

  9. [Isokinetic assessment with two years follow-up of anterior cruciate ligament reconstruction with patellar tendon or hamstring tendons].

    PubMed

    Condouret, J; Cohn, J; Ferret, J-M; Lemonsu, A; Vasconcelos, W; Dejour, D; Potel, J-F

    2008-12-01

    This retrospective multicentric study was designed to assess the outcome of quadriceps and hamstrings muscles two years after Anterior Cruciate Ligament (ACL) reconstruction and compare muscles recovery depending on the type of graft and individual variables like age, gender, level of sport, but also in terms of discomfort, pain and functional score. The results focused on the subjective and objective IKDC scores, SF36, the existence or not of subjective disorders and their location. The review included isokinetic muscle tests concentric and eccentric extensors/flexors but also internal rotators/external rotators with analysis of mean work and mean power. One hundred and twenty-seven patients were included with an average age 29 years (+/-10). They all had an ACL reconstruction with patellar tendon or hamstring tendon with single or double bundles. In the serie, the average muscles deficit at two years was 10% for the flexors and extensors but with a significant dispersion. Significant differences were not noted in the mean values of all parameters in term of sex or age (over 30 years or not), neither the type of sport, nor of clinical assessment (Class A and B of objective IKDC score), nor the existence of anterior knee pain. There was a relationship between the level of extensor or flexor recovery and the quality of functional results with minimal muscle deficits close to 5% if the IKDC score was over 90 and deficits falling to 15% in the group with IKDC score less than 90. The type of reconstruction (patellar tendon versus hamstrings) had an influence on the muscle deficit. For extensors, the recovery was the same in the two groups, more than 90% at two years and the distribution of these two populations by level of deficit was quite the same. For flexors, residual deficits were significantly higher in the hamstrings group on the three studied parameters whatever the speed and the type of contraction (concentric or eccentric) with an average deficit of 14 to 18%, while, in the patellar tendon group, there was a dominance over the opposite side of 2 to 3% in concentric contraction. The hamstrings deficit appears to be "harvest dependent". For internal rotators, a significantly higher deficit is observed in eccentric contraction for the hamstrings group. The residual hamstrings deficits were related to the number of tendons harvested: -7% when there was no harvest, 7% with one tendon harvested and 17% with two tendons harvested. The relationship between the level of recovery of the quadriceps muscle and hamstrings at two years and the quality of functional results incite, regarding the significantly higher deficit of flexors in ACL reconstructions with hamstrings, to change the rehabilitation programs and especially on early rehabilitation of hamstrings in eccentric mode in the early weeks postoperative considering the harvest site as an equivalent of muscle tear.

  10. Nickel-titanium wire in circumferential suture of a flexor tendon repair: a comparison to polypropylene.

    PubMed

    Karjalainen, T; He, M; Chong, A K S; Lim, A Y T; Ryhanen, J

    2010-07-01

    Nickel-titanium (NiTi) has been proposed as an alternative material for flexor tendon core suture. To our knowledge, its suitability as a circumferential suture of flexor tendon repair has not been investigated before. The purpose of this ex vivo study was to investigate the biomechanical properties of NiTi circumferential repairs and to compare them with commonly used polypropylene. Forty porcine flexor tendons were cut and repaired by simple running or interlocking mattress technique using 100 microm NiTi wire or 6-0 polypropylene. The NiTi circumferential repairs showed superior stiffness, gap resistance, and load to failure when compared to polypropylene repairs with both techniques. Nickel-titanium wire seems to be a potential material for circumferential repair of flexor tendons. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. Effect of tendon tensioning: an in vitro study in porcine extensor tendons.

    PubMed

    Figueroa, David; Calvo, Rafael; Vaisman, Alex; Meleán, Patricio; Figueroa, Francisco

    2010-06-01

    Graft tensioning is a controversial issue in anterior cruciate ligament reconstruction (ACLR) that has not achieved consensus between peers. The purpose of this study is to determine if after tensioning tendon length and resistance to maximal load changes. We performed an in vitro study with 50 porcine extensors tendons. The first group (P=25) was tensioned with 80 N (19.97 lb) for 10 min, using an ACL graft preparation board. The second group (C=25) was used as control and was not tensioned. The average initial (groups P and C) and post tensioning tendon length (group C) were measured; the average initial and post tensioning tendon diameter were measured as well. All samples were fixated in a tube-clamp system connected to a tension sensor. The samples were stressed with continuous and progressive tension until ultimate failure at maximum load (UFML) occurs. The initial mean length was: P before tensioning=13.4 mm+/-1.4 mm (range 10.5-16.5); P after tensioning=13.8 mm+/-1.4 mm (range 11.5-16.5); C=13 mm+/-1.35 mm (p=0.005). The mean diameter was: P=5.6 mm (4.5-6); C=5.5 mm (range 4.5-6) (p>0.05). The UFML was: P=189.7 N (114-336); C=229.9 N (143-365) (p=0.029). Tendon tensioning with 80 N for 10 min produced 3% average elongation. These could be beneficial in ACLR since tendon tensioning decreases elongation of the graft after fixation. Regardless, tendon tensioning is not innocuous since it diminishes their resistance when continuously stressed until complete failure occurs.

  12. Macroscopic Rotator Cuff Tendinopathy and Histopathology Do Not Predict Repair Outcomes of Rotator Cuff Tears.

    PubMed

    Sethi, Paul M; Sheth, Chirag D; Pauzenberger, Leo; McCarthy, Mary Beth R; Cote, Mark P; Soneson, Emma; Miller, Seth; Mazzocca, Augustus D

    2018-03-01

    Numerous studies have identified factors that may affect the chances of rotator cuff healing after surgery. Intraoperative tendon quality may be used to predict healing and to determine type of repair and/or consideration of augmentation. There are no data that correlate how gross tendon morphology and degree of tendinopathy affect patient outcome or postoperative tendon healing. Purpose/Hypothesis: The purposes of this study were to (1) compare the gross appearance of the tendon edge during arthroscopic rotator cuff repair with its histological degree of tendinopathy and (2) determine if gross appearance correlated with postoperative repair integrity. The hypothesis was that gross (macroscopic) tendon with normal thickness, no delamination, and elastic tissue before repair would have a correlation with low Bonar scores, higher postoperative American Shoulder and Elbow Surgeons (ASES) scores, and increased rates of postoperative tendon healing on ultrasound. Cross-sectional study; Level of evidence, 3. A total of 105 patients undergoing repair of medium-size (1-3 cm) full-thickness rotator cuff tears were enrolled in the study. Intraoperatively, the supraspinatus tendon was rated on thickness, fraying, and stiffness. Tendon tissue was recovered for histological analysis based on the Bonar scoring system. Postoperative ASES and ultrasound assessment of healing were obtained 1 year after repair. Correlation between gross appearance of the tendon and rotator cuff histology was determined. Of the 105 patients, 85 were followed the study to completion. The mean age of the patients was 61.6 years; Bonar score, 7.5; preoperative ASES score, 49; and postoperative ASES score, 86. Ninety-one percent of repairs were intact on ultrasound. Gross appearance of torn rotator cuff tendon tissue did not correlate with histological appearance. Neither histological (Bonar) score nor gross appearance correlated with multivariate analysis of ASES score, postoperative repair status, or demographic data. The degree of tendinopathy did not correlate with morphological appearance of the tendon. Neither of these parameters correlated with healing or patient outcome. This study suggests that the degree of tendinopathy, unlike muscle atrophy, may not be predictive of outcomes and that, on appearance, poor quality tendon has adequate healing capacity. Therefore, abnormal gross tendon appearance should not affect the repair effort or technique.

  13. Chronic Degeneration Leads to Poor Healing of Repaired Massive Rotator Cuff Tears in Rats.

    PubMed

    Killian, Megan L; Cavinatto, Leonardo M; Ward, Samuel R; Havlioglu, Necat; Thomopoulos, Stavros; Galatz, Leesa M

    2015-10-01

    Chronic rotator cuff tears present a clinical challenge, often with poor outcomes after surgical repair. Degenerative changes to the muscle, tendon, and bone are thought to hinder healing after surgical repair; additionally, the ability to overcome degenerative changes after surgical repair remains unclear. The purpose of this study was to evaluate healing outcomes of muscle, tendon, and bone after tendon repair in a model of chronic rotator cuff disease and to compare these outcomes to those of acute rotator cuff injuries and repair. The hypothesis was that degenerative rotator cuff changes associated with chronic multitendon tears and muscle unloading would lead to poor structural and mechanical outcomes after repair compared with acute injuries and repair. Controlled laboratory study. Chronic rotator cuff injuries, induced via detachment of the supraspinatus (SS) and infraspinatus (IS) tendons and injection of botulinum toxin A into the SS and IS muscle bellies, were created in the shoulders of rats. After 8 weeks of injury, tendons were surgically reattached to the humeral head, and an acute, dual-tendon injury and repair was performed on the contralateral side. After 8 weeks of healing, muscles were examined histologically, and tendon-to-bone samples were examined microscopically, histologically, and biomechanically and via micro-computed tomography. All repairs were intact at the time of dissection, with no evidence of gapping or ruptures. Tendon-to-bone healing after repair in our chronic injury model led to reduced bone quality and morphological disorganization at the repair site compared with acute injuries and repair. SS and IS muscles were atrophic at 8 weeks after repair of chronic injuries, indicating incomplete recovery after repair, whereas SS and IS muscles exhibited less atrophy and degeneration in the acute injury group at 8 weeks after repair. After chronic injuries and repair, humeral heads had decreased total mineral density and an altered trabecular structure, and the repair had decreased strength, stiffness, and toughness, compared with the acute injury and repair group. Chronic degenerative changes in rotator cuff muscles, tendons, and bone led to inferior healing characteristics after repair compared with acute injuries and repair. The changes were not reversible after repair in the time course studied, consistent with clinical impressions. High retear rates after rotator cuff repair are associated with tear size and chronicity. Understanding the mechanisms behind this association may allow for targeted tissue therapy for tissue degeneration that occurs in the setting of chronic tears. © 2015 The Author(s).

  14. Chronic Degeneration Leads to Poor Healing of Repaired Massive Rotator Cuff Tears in Rats

    PubMed Central

    Killian, Megan L.; Cavinatto, Leonardo M.; Ward, Samuel R.; Havlioglu, Necat; Thomopoulos, Stavros; Galatz, Leesa M.

    2016-01-01

    Background Chronic rotator cuff tears present a clinical challenge, often with poor outcomes after surgical repair. Degenerative changes to the muscle, tendon, and bone are thought to hinder healing after surgical repair; additionally, the ability to overcome degenerative changes after surgical repair remains unclear. Purpose/Hypothesis The purpose of this study was to evaluate healing outcomes of muscle, tendon, and bone after tendon repair in a model of chronic rotator cuff disease and to compare these outcomes to those of acute rotator cuff injuries and repair. The hypothesis was that degenerative rotator cuff changes associated with chronic multitendon tears and muscle unloading would lead to poor structural and mechanical outcomes after repair compared with acute injuries and repair. Study Design Controlled laboratory study. Methods Chronic rotator cuff injuries, induced via detachment of the supraspinatus (SS) and infraspinatus (IS) tendons and injection of botulinum toxin A into the SS and IS muscle bellies, were created in the shoulders of rats. After 8 weeks of injury, tendons were surgically reattached to the humeral head, and an acute, dual-tendon injury and repair was performed on the contralateral side. After 8 weeks of healing, muscles were examined histologically, and tendon-to-bone samples were examined microscopically, histologically, and biomechanically and via micro–computed tomography. Results All repairs were intact at the time of dissection, with no evidence of gapping or ruptures. Tendon-to-bone healing after repair in our chronic injury model led to reduced bone quality and morphological disorganization at the repair site compared with acute injuries and repair. SS and IS muscles were atrophic at 8 weeks after repair of chronic injuries, indicating incomplete recovery after repair, whereas SS and IS muscles exhibited less atrophy and degeneration in the acute injury group at 8 weeks after repair. After chronic injuries and repair, humeral heads had decreased total mineral density and an altered trabecular structure, and the repair had decreased strength, stiffness, and toughness, compared with the acute injury and repair group. Conclusion Chronic degenerative changes in rotator cuff muscles, tendons, and bone led to inferior healing characteristics after repair compared with acute injuries and repair. The changes were not reversible after repair in the time course studied, consistent with clinical impressions. Clinical Relevance High retear rates after rotator cuff repair are associated with tear size and chronicity. Understanding the mechanisms behind this association may allow for targeted tissue therapy for tissue degeneration that occurs in the setting of chronic tears. PMID:26297522

  15. The effects of chronic unloading and gap formation on tendon-to-bone healing in a rat model of massive rotator cuff tears

    PubMed Central

    Killian, Megan L.; Cavinatto, Leonardo; Shah, Shivam A.; Sato, Eugene J.; Ward, Samuel R.; Havlioglu, Necat; Galatz, Leesa M.; Thomopoulos, Stavros

    2014-01-01

    The objective of this study was to understand the effect of pre-repair rotator cuff chronicity on post-repair healing outcomes using a chronic and acute multi-tendon rat rotator cuff injury model. Full-thickness dual tendon injuries (supra- and infraspinatus) were created unilaterally in adult male Sprague Dawley rats, and left chronically detached for 8 or 16 weeks. After chronic detachment, tears were repaired and acute dual tendon injuries were created and immediately repaired on contralateral shoulders. Tissue level outcomes for bone, tendon, and muscle were assessed 4 or 8 weeks after repair using histology, microcomputed tomography, biomechanical testing, and biochemical assays. Substantial gap formation was seen in 35% of acute repairs and 44% of chronic repairs. Gap formation negatively correlated with mechanical and structural outcomes for both healing time points regardless of injury duration. Bone and histomorphometry, as well as biomechanics, were similar between acute and chronic injury and repair regardless of chronicity and duration of healing. This study was the first to implement a multi-tendon rotator cuff injury with surgical repair following both chronic and acute injuries. Massive tear in a rodent model resulted in gap formation regardless of injury duration which had detrimental effects on repair outcomes. PMID:24243733

  16. Effect of the Interposition of Calcium Phosphate Materials on Tendon-Bone Healing During Repair of Chronic Rotator Cuff Tear.

    PubMed

    Zhao, Song; Peng, Lingjie; Xie, Guoming; Li, Dingfeng; Zhao, Jinzhong; Ning, Congqin

    2014-08-01

    The current nature of tendon-bone healing after rotator cuff (RC) repair is still the formation of granulation tissue at the tendon-bone interface rather than the formation of fibrocartilage, which is the crucial structure in native tendon insertion and can be observed after knee ligament reconstruction. The interposition of calcium phosphate materials has been found to be able to enhance tendon-bone healing in knee ligament reconstruction. However, whether the interposition of these kinds of materials can enhance tendon-bone healing or even change the current nature of tendon-bone healing after RC repair still needs to be explored. The interposition of calcium phosphate materials during RC repair would enhance tendon-bone healing or change its current nature of granulation tissue formation into a more favorable process. Controlled laboratory study. A total of 144 male Sprague-Dawley rats underwent unilateral detachment of the supraspinatus tendon, followed by delayed repair after 3 weeks. The animals were allocated into 1 of 3 groups: (1) repair alone, (2) repair with Ca5(PO4)2SiO4 (CPS) bioceramic interposition, or (3) repair with hydroxyapatite (HA) bioceramic interposition at the tendon-bone interface. Animals were sacrificed at 2, 4, or 8 weeks postoperatively, and microcomputed tomography (micro-CT) was used to quantify the new bone formation at the repair site. New fibrocartilage formation and collagen organization at the tendon-bone interface was evaluated by histomorphometric analysis. Biomechanical testing of the supraspinatus tendon-bone complex was performed. Statistical analysis was performed using 1-way analysis of variance. Significance was set at P < .05. The micro-CT analysis demonstrated remarkable osteogenic activity and osteoconductivity to promote new bone formation and ingrowth of CPS and HA bioceramic, with CPS bioceramic showing better results than HA. Histological observations indicated that CPS bioceramic had excellent biocompatibility and biodegradability. At early time points after the RC repair, CPS bioceramic significantly increased the area of fibrocartilage at the tendon-bone interface compared with the control and HA groups. Moreover, CPS and HA bioceramics had significantly improved collagen organization. Biomechanical tests indicated that the CPS and HA groups have greater ultimate load to failure and stiffness than the control group at 4 and 8 weeks, and the CPS specimens exhibited the maximum ultimate load to failure, stiffness, and stress of the healing enthesis. Both CPS and HA bioceramics aid in cell attachment and proliferation and accelerate new bone formation, and CPS bioceramic has a more prominent effect on tendon-to-bone healing. Local application of CPS and HA bioceramic at the tendon-bone interface shows promise in improving healing after rotator cuff tear repair. © 2014 The Author(s).

  17. Mechanical Strength of the Side-to-Side Versus Pulvertaft Weave Tendon Repair

    PubMed Central

    Brown, Stephen H. M.; Hentzen, Eric R.; Kwan, Alan; Ward, Samuel R.; Fridén, Jan; Lieber, Richard L.

    2010-01-01

    Purpose The side-to-side (SS) tendon suture technique was designed to function as a repair that permits immediate post-operative activation and mobilization of a transferred muscle. This study was designed to test the strength and stiffness of the SS technique against a variation of the Pulvertaft (PT) repair technique. Methods Flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) tendons were harvested from four fresh cadavers and used as a model system. Seven SS and six PT repairs were performed using the FDS as the donor and the FDP as the recipient tendon. For SS repairs, the FDS was woven through one incision in the FDP, and was joined with four cross-stitch running sutures down both sides, and one double-loop suture at each tendon free end; for PT repairs, FDS was woven through three incisions in FDP, joined with a double-loop suture at both ends of the overlap, and four evenly spaced mattress sutures between the ends. Tendon repairs were placed in a tensile testing machine, pre-conditioned and tested to failure. Results There were no statistically significant differences in cross-sectional area (p=0.99) or initial length (p=0.93) between SS and PT repairs. Therefore, all comparisons between methods were made using measures of loads and deformations, rather than stresses and strains.. All failures occurred in the repair region, rather than at the clamps. However, failure mechanisms were different between the two techniques—PT repairs failed by the suture knots either slipping or pulling through the tendon material, followed by the FDS tendon pulling through the FDP tendon; SS repairs failed by shearing of fibers within the FDS. Load at first failure (p < 0.01), ultimate load (p < 0.001), and repair stiffness (p < 0.05) were all significantly different between SS and PT techniques; in all cases the mean value for SS was higher than for PT. Discussion The SS repair, using a cross-stitch suture technique, was significantly stronger and stiffer compared to the PT repair using a mattress suture technique. This suggests that using SS repairs could enable patients to load the repair soon after surgery. Ultimately, this should reduce the risk of developing adhesions and result in improved functional outcome and fewer complications in the acute post-operative period. Future work will address the specific mechanisms (for example, suture-throw technique, tendon-weave technique) that underlie the improved strength and stiffness of the SS repair. PMID:20223604

  18. Tendon injuries

    PubMed Central

    Wu, Fan; Nerlich, Michael; Docheva, Denitsa

    2017-01-01

    Tendons connect muscles to bones, ensuring joint movement. With advanced age, tendons become more prone to degeneration followed by injuries. Tendon repair often requires lengthy periods of rehabilitation, especially in elderly patients. Existing medical and surgical treatments often fail to regain full tendon function. The development of novel treatment methods has been hampered due to limited understanding of basic tendon biology. Recently, it was discovered that tendons, similar to other mesenchymal tissues, contain tendon stem/progenitor cells (TSPCs) which possess the common stem cell properties. The current strategies for enhancing tendon repair consist mainly of applying stem cells, growth factors, natural and artificial biomaterials alone or in combination. In this review, we summarise the basic biology of tendon tissues and provide an update on the latest repair proposals for tendon tears. Cite this article: EFORT Open Rev 2017;2:332-342. DOI: 10.1302/2058-5241.2.160075 PMID:28828182

  19. Chronic triceps insufficiency managed with extensor carpi radialis longus and palmaris longus tendon grafts.

    PubMed

    Singh, Dhanpal; Kumar, K Arun; Dinesh, Mc; Raj, Ranju

    2012-03-01

    Chronic triceps insufficiency, causing prolonged disability, occurs due to a missed diagnosis of an acute rupture. We report a 25 year old male with history of a significant fall sustaining multiple injuries. Since then, he had inability in extending his right elbow for which he sought intervention after a year. Diagnosis of triceps rupture was made clinicoradiologically and surgery was planned. Intraoperative findings revealed a deficient triceps with a fleck of avulsed bone from olecranon. Ipsilateral double tendon graft including extensor carpi radialis longus and palmaris longus were anchored to triceps and secured with the olecranon. Six-months follow revealed a complete active extension of elbow and a full function at the donor site.

  20. Chronic rotator cuff injury and repair model in sheep.

    PubMed

    Coleman, Struan H; Fealy, Stephen; Ehteshami, John R; MacGillivray, John D; Altchek, David W; Warren, Russell F; Turner, A Simon

    2003-12-01

    Most rotator cuff surgery is performed on chronic tears. As there is no animal model in which to examine the physiology of muscle and tendon injury and repair in this setting, we developed a chronic rotator cuff injury model in sheep. The infraspinatus tendon was released in thirty-six female sheep. Biopsy specimens were obtained from the muscle and were analyzed for fat content. The force generated by the muscle with supramaximal stimulation was recorded intraoperatively. A control group (twelve sheep) underwent an immediate tendon repair. In the remaining twenty-four sheep, the tendon was wrapped in a dura substitute to prevent scarring and was repaired at six weeks (eight sheep) and eighteen weeks (sixteen sheep) after release. In the immediate repair group, four animals were killed at six weeks; four, at twelve weeks; and four, at twenty weeks. In the six-week delayed repair group, four animals were killed at twelve weeks and four were killed at twenty weeks after the repair. In the eighteen-week delayed repair group, eight animals were killed at twelve weeks; four, at twenty weeks; and four, at thirty weeks after the repair. Muscle biopsies and testing were repeated prior to killing of the animals. The average force of muscle contraction decreased 3.6 lb (1.6 kg) by six weeks after the injury and 3.9 lb (1.8 kg) by eighteen weeks after the injury. After the repair, the force of contraction in the six-week group improved by 0.8 lb (0.4 kg) at twelve weeks postoperatively and by 1.3 lb (0.6 kg) at twenty weeks postoperatively. In contrast, no improvement occurred in the eighteen-week group until thirty weeks after the repair, at which time a 0.9-lb (0.4-kg) improvement was noted. There was a twelvefold increase in intramuscular fat concentration; this lipid infiltration was partially reversed after the tendon repair. Isolated tendon samples demonstrated an increase in the modulus of elasticity after chronic detachment that partially corrected after the tendon repair in the earlier (six-week) repair group. We found that earlier repair of the tendon results in a more rapid recovery of both muscle function and tendon elasticity compared with a more delayed repair. We concluded that there may be a "point of no return" in rotator cuff injury after which the elasticity of the muscle-tendon unit does not return to normal.

  1. The effect of a collagen-elastin matrix on adhesion formation after flexor tendon repair in a rabbit model.

    PubMed

    Wichelhaus, Dagmar Alice; Beyersdoerfer, Sascha Tobias; Gierer, Philip; Vollmar, Brigitte; Mittlmeier, Th

    2016-07-01

    The outcome of flexor tendon surgery is negatively affected by the formation of adhesions which can occur during the healing of the tendon repair. In this experimental study, we sought to prevent adhesion formation by wrapping a collagen-elastin scaffold around the repaired tendon segment. In 28 rabbit hind legs, the flexor tendons of the third and fourth digits were cut and then repaired using a two-strand suture technique on the fourth digit and a four-strand technique on the third digit. Rabbits were randomly assigned to study and control groups. In the control group, the operation ended by closing the tendon sheath and the skin. In the study group, a collagen-elastin scaffold was wrapped around the repaired tendon segment in both digits. After 3 and 8 weeks, the tendons were harvested and processed histologically. The range of motion of the digits and the gap formation between the repaired tendon ends were measured. The formation of adhesions, infiltration of leucocytes and extracellular inflammatory response were quantified. At the time of tendon harvesting, all joints of the operated toes showed free range of motion. Four-strand core sutures lead to significantly less diastasis between the repaired tendon ends than two-strand core suture repairs. The collagen-elastin scaffold leads to greater gapping after 3 weeks compared to the controls treated without the matrix. Within the tendons treated with the collagen-elastin matrix, a significant boost of cellular and extracellular inflammation could be stated after 3 weeks which was reflected by a higher level of CAE positive cells and more formation of myofibroblasts in the αSMA stain in the study group. The inflammatory response subsided gradually and significantly until the late stage of the study. Both the cellular and extracellular inflammatory response was emphasized with the amount of material used for the repair. The use of a collagen-elastin matrix cannot be advised for the prevention of adhesion formation in flexor tendon surgery, because it enhances both cellular and extracellular inflammation. Four-strand core sutures lead to less gapping than two-strand core sutures, but at the same time, the cellular and extracellular inflammatory response is more pronounced.

  2. [Quadriceps tendon insufficiency and rupture : Treatment options in total knee arthroplasty].

    PubMed

    Thiele, K; von Roth, P; Pfitzner, T; Preininger, B; Perka, C

    2016-05-01

    Quadriceps tendon injuries and insufficiencies in total knee arthroplasty are rare, but are followed by a devastating complication that left untreated leads to a complete loss of function of the knee. This review article summarizes the functional anatomy, risk factors, and the prevalence and diagnosis of quadriceps tendon injuries, in addition to the possible management options for partial and complete ruptures. The treatment options are adapted according to the extent of the loss of function (partial, complete) and the duration of the injury (acute vs chronic). Furthermore, the choice of treatment should take into account the quality and availability of primary tissue, the patient's general health, along with their likely functional requirements. Conservative treatment is often justified in partial ruptures with good results. Complete ruptures require surgical intervention and multiple operative techniques are described. Treatment options for acute ruptures include direct primary repair with autogenous or synthetic tissue augmentation. In the case of chronic insufficiency and a lack of soft-tissue surroundings, reconstruction with the aid of a muscle flap or allograft tissue can be considered. All surgical intervention techniques used so far have been fraught with complications and rarely lead to satisfactory results. A new surgical approach to the reconstruction and augmentation of the extensor mechanism consists of the use of a synthetic mesh. The technique is described here in detail.

  3. Fibularis tertius: revisiting the anatomy.

    PubMed

    Rourke, K; Dafydd, H; Parkin, I G

    2007-11-01

    Fibularis tertius (FT) may be used during reconstructive surgery and muscle transposition with retention of function. The muscle was examined in both lower limbs of 41 cadavers. Measurements were made of muscle belly length and width, tendon length and width, and the size of the origin on the fibula. Tendon insertion, nerve and blood supplies were also examined. FT was absent in five (6.1%) lower limbs of three (7.3%) subjects. The size of its origin demonstrated inter- and intra-individual variation. FT arose from the distal fibula and on average occupied (28.4 +/- 9.1)% (mean +/- S. D.) of the total shaft length. In all cases the tendon inserted into the dorsal surface of the shafts of both the fourth and fifth metatarsals. A small nerve branch consistently arose from the deep fibular nerve near the origin of extensor digitorum longus. The nerve ran parallel to the length of this muscle, between it and extensor hallucis longus, before piercing FT. Anatomy textbooks describe FT as inserting into the fifth metatarsal only. This study, supported by data from previous reports, suggests that the "textbook" accounts of FT should be updated to record that most commonly its tendon reaches both the fourth and fifth metatarsals.

  4. Biomechanical characteristics of the horizontal mattress stitch: implication for double-row and suture-bridge rotator cuff repair.

    PubMed

    Tamboli, Mallika; Mihata, Teruhisa; Hwang, James; McGarry, Michelle H; Kang, Yangmi; Lee, Thay Q

    2014-03-01

    We investigated the effects of bite-size horizontal mattress stitch (distance between the limbs passed through the tendon) on the biomechanical properties of the repaired tendon. We anchored 20 bovine Achilles tendons to bone using no. 2 high-strength suture and 5-mm titanium suture anchors in a mattress-suture technique. Tendons were allocated randomly into two groups of ten each to receive stitches with a 4- or 10-mm bite. Specimens underwent cyclic loading from 5 to 30 N at 1 mm/s for 30 cycles, followed by tensile testing to failure. Gap formation, tendon strain, hysteresis, stiffness, yield load, ultimate load, energy to yield load, and energy to ultimate load were compared between groups using unpaired t tests. The 4-mm group had less (p < 0.05) gap formation and less (p < 0.05) longitudinal strain than did the 10-mm group. Ultimate load (293.6 vs. 148.9 N) and energy to ultimate load (2,563 vs. 1,472 N-mm) were greater (p < 0.001) for the 10-mm group than the 4-mm group. All tendons repaired with 4-mm suturing failed at the suture-tendon interface, with sutures pulling through the tendon, whereas the suture itself failed before the tendon did in seven of the ten specimens in the 10-mm group. Whereas a 4-mm bite fixed the tendon more tightly but at the cost of decreased ultimate strength, a 10-mm bite conveyed greater ultimate strength but with increased gap and strain. These results suggest that for the conventional double-row repair, small mattress stitches provide a tighter repair, whereas large stitches are beneficial to prevent sutures from pulling through the tendon after surgery. For suture-bridge rotator cuff repair, large stitches are beneficial because the repaired tendon has a higher strength, and the slightly mobile medial knot can be tightened by lateral fixation.

  5. Augmentation of Rotator Cuff Repair With Soft Tissue Scaffolds

    PubMed Central

    Thangarajah, Tanujan; Pendegrass, Catherine J.; Shahbazi, Shirin; Lambert, Simon; Alexander, Susan; Blunn, Gordon W.

    2015-01-01

    Background Tears of the rotator cuff are one of the most common tendon disorders. Treatment often includes surgical repair, but the rate of failure to gain or maintain healing has been reported to be as high as 94%. This has been substantially attributed to the inadequate capacity of tendon to heal once damaged, particularly to bone at the enthesis. A number of strategies have been developed to improve tendon-bone healing, tendon-tendon healing, and tendon regeneration. Scaffolds have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects but may not possess situation-specific or durable mechanical and biological characteristics. Purpose To provide an overview of the biology of tendon-bone healing and the current scaffolds used to augment rotator cuff repairs. Study Design Systematic review; Level of evidence, 4. Methods A preliminary literature search of MEDLINE and Embase databases was performed using the terms rotator cuff scaffolds, rotator cuff augmentation, allografts for rotator cuff repair, xenografts for rotator cuff repair, and synthetic grafts for rotator cuff repair. Results The search identified 438 unique articles. Of these, 214 articles were irrelevant to the topic and were therefore excluded. This left a total of 224 studies that were suitable for analysis. Conclusion A number of novel biomaterials have been developed into biologically and mechanically favorable scaffolds. Few clinical trials have examined their effect on tendon-bone healing in well-designed, long-term follow-up studies with appropriate control groups. While there is still considerable work to be done before scaffolds are introduced into routine clinical practice, there does appear to be a clear indication for their use as an interpositional graft for large and massive retracted rotator cuff tears and when repairing a poor-quality degenerative tendon. PMID:26665095

  6. ArthroBroström Lateral Ankle Stabilization Technique: An Anatomic Study.

    PubMed

    Acevedo, Jorge I; Ortiz, Cristian; Golano, Pau; Nery, Caio

    2015-10-01

    Arthroscopic ankle lateral ligament repair techniques have recently been developed and biomechanically as well as clinically validated. Although there has been 1 anatomic study relating suture and anchor proximity to anatomic structures, none has evaluated the ArthroBroström procedure. To evaluate the proximity of anatomic structures for the ArthroBroström lateral ankle ligament stabilization technique and to define ideal landmarks and "safe zones" for this repair. Descriptive laboratory study. Ten human cadaveric ankle specimens (5 matched pairs) were screened for the study. All specimens underwent arthroscopic lateral ligament repair according to the previously described ArthroBroström technique with 2 suture anchors in the fibula. Three cadaveric specimens were used to test the protocol, and 7 were dissected to determine the proximity of anatomic structures. Several distances were measured, including those of different anatomic structures to the suture knots, to determine the "safe zones." Measurements were obtained by 2 separate observers, and statistical analysis was performed. None of the specimens revealed entrapment by either of the suture knots of the critical anatomic structures, including the superficial peroneal nerve (SPN), sural nerve, peroneus tertius tendon, peroneus brevis tendon, or peroneus longus tendon. The internervous safe zone between the intermediate branch of the SPN and sural nerve was a mean of 51 mm (range, 39-64 mm). The intertendinous safe zone between the peroneus tertius and peroneus brevis was a mean of 43 mm (range, 37-49 mm). On average, a 20-mm (range, 8-36 mm) safe distance was maintained from the most medial suture to the intermediate branch of the SPN. The amount of inferior extensor retinaculum (IER) grasped by either suture knot varied from 0 to 12 mm, with 86% of repairs including the retinaculum. The results indicate that there is a relatively wide internervous and intertendinous safe zone when performing the ArthroBroström technique for lateral ankle stabilization. While none of the critical anatomic structures was entrapped by the suture knots, it was evident that the IER was included in a majority of the repairs. This study further defines the proximity of adjacent anatomic structures and establishes the anatomic safe zones for the ArthroBroström lateral ankle stabilization procedure. By defining this relatively risk-free zone, surgeons who are not as experienced with arthroscopic lateral ligament repair techniques may approach arthroscopic suture passage with more confidence. © 2015 The Author(s).

  7. Peroneal perforator-based peroneus longus tendon and sural neurofasciocutaneous composite flap transfer for a large soft-tissue defect of the forearm: A case report.

    PubMed

    Hayashida, Kenji; Saijo, Hiroto; Fujioka, Masaki

    2018-01-01

    We describe the use of a composite flap composed of a sural neurofasciocutaneous flap and a vascularized peroneus longus tendon for the reconstruction of severe composite forearm tissue defects in a patient. A 43-year-old man had his left arm caught in a conveyor belt resulting in a large soft-tissue defect of 18 × 11 cm over the dorsum forearm. The extensor carpi radialis, superficial radial nerve, and radial artery were severely damaged. A free neurofasciocutaneous composite flap measuring 16 × 11 cm was outlined on the patient's left lower leg to allow simultaneous skin, tendon, nerve, and artery reconstruction. The flap, which included the peroneus longus tendon, was elevated on the subfascial plane. After the flap was transferred to the recipient site, the peroneal artery was anastomosed to the radial artery in a flow-through manner. The vascularized tendon graft with 15 cm in length was used to reconstruct the extensor carpi radialis longus tendon defect using an interlacing suture technique. As the skin paddle of the sural neurofasciocutaneous flap and the vascularized peroneus longus tendon graft were linked by the perforator and minimal fascial tissue, the skin paddle was able to rotate and slide with comparative ease. The flap survived completely without any complications. The length of follow-up was 12 months and was uneventful. Range of motion of his left wrist joint was slightly limited to 75 degrees. This novel composite flap may be useful for reconstructing long tendon defects associated with extensive forearm soft tissue defects. © 2016 Wiley Periodicals, Inc.

  8. The effects of chronic unloading and gap formation on tendon-to-bone healing in a rat model of massive rotator cuff tears.

    PubMed

    Killian, Megan L; Cavinatto, Leonardo; Shah, Shivam A; Sato, Eugene J; Ward, Samuel R; Havlioglu, Necat; Galatz, Leesa M; Thomopoulos, Stavros

    2014-03-01

    The objective of this study was to understand the effect of pre-repair rotator cuff chronicity on post-repair healing outcomes using a chronic and acute multi-tendon rat rotator cuff injury model. Full-thickness dual tendon injuries (supra- and infraspinatus) were created unilaterally in adult male Sprague Dawley rats, and left chronically detached for 8 or 16 weeks. After chronic detachment, tears were repaired and acute dual tendon injuries were created and immediately repaired on contralateral shoulders. Tissue level outcomes for bone, tendon, and muscle were assessed 4 or 8 weeks after repair using histology, microcomputed tomography, biomechanical testing, and biochemical assays. Substantial gap formation was seen in 35% of acute repairs and 44% of chronic repairs. Gap formation negatively correlated with mechanical and structural outcomes for both healing time points regardless of injury duration. Bone and histomorphometry, as well as biomechanics, were similar between acute and chronic injury and repair regardless of chronicity and duration of healing. This study was the first to implement a multi-tendon rotator cuff injury with surgical repair following both chronic and acute injuries. Massive tear in a rodent model resulted in gap formation regardless of injury duration which had detrimental effects on repair outcomes. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  9. Differential activation of motor units in the wrist extensor muscles during the tonic vibration reflex in man.

    PubMed Central

    Romaiguère, P; Vedel, J P; Azulay, J P; Pagni, S

    1991-01-01

    1. Single motor unit activity was recorded in the extensor carpi radialis longus and extensor carpi radialis brevis muscles of five healthy human subjects, using metal microelectrodes. 2. Motor units were characterized on the basis of their twitch contraction times and their force recruitment thresholds during voluntary imposed-ramp contractions. 3. The discharge patterns of forty-three motor units were studied during tonic vibration reflex elicited by prolonged (150 s) trains of vibration (30 Hz) applied to the distal tendons of the muscles. The temporal relationships between the individual small tendon taps of the vibratory stimulus and the motor unit impulses were analysed on dot raster displays and post-stimulus time histograms. 4. After tendon taps, the impulses of motor units with long twitch contraction times (mean +/- S.D., 47.2 +/- 10.7 ms) and low recruitment thresholds (0.88 +/- 0.6 N) formed a single narrow peak (P1) with a latency (22.7 +/- 1.4 ms) which was comparable to that of the tendon jerk in the extensor carpi radialis muscles. These motor units were named 'P1 units'. On the other hand, the response of motor units with shorter twitch contraction times (31.1 +/- 3.3 ms) and higher recruitment thresholds (3.21 +/- 1.3 N) showed two peaks: a short latency (23.4 +/- 1.3 ms) P1 peak similar to the previous one and a P2 peak occurring 9.4 +/- 1.2 ms later. These motor units were named 'P1-P2 units'. 5. When the reflex contraction increased slowly, the P1 peaks of 'P1-P2 units' were clearly predominant at the beginning of the contraction, during the rising phase of the motor unit discharge frequency, while the P2 peaks became predominant when the units had reached their maximal discharge frequency. 6. Increasing the tendon vibration frequency (35, 55, 75, 95 Hz) did not modify the 'P1 unit' discharge pattern. Due to interference between vibration period and peak latencies, increasing the vibration frequency caused the P1 and P2 peaks of 'P1-P2 units' to overlap. 7. Superficial cutaneous stimulation of the dorsal side of the forearm during tendon vibration noticeably decreased the P1 peaks in both types of motor units. In the P2 peaks it could result in either a decrease or an increase but the average effect was a slight increase. 8. When applied 10 s before tendon vibration, cutaneous stimulation considerably suppressed the tonic vibration reflex.(ABSTRACT TRUNCATED AT 400 WORDS) PMID:1822565

  10. What We Should Know Before Using Tissue Engineering Techniques to Repair Injured Tendons: A Developmental Biology Perspective

    PubMed Central

    Liu, Chia-Feng; Aschbacher-Smith, Lindsey; Barthelery, Nicolas J.; Dyment, Nathaniel; Butler, David

    2011-01-01

    Tendons connect muscles to bones, and serve as the transmitters of force that allow all the movements of the body. Tenocytes are the basic cellular units of tendons, and produce the collagens that form the hierarchical fiber system of the tendon. Tendon injuries are common, and difficult to repair, particularly in the case of the insertion of tendon into bone. Successful attempts at cell-based repair therapies will require an understanding of the normal development of tendon tissues, including their differentiated regions such as the fibrous mid-section and fibrocartilaginous insertion site. Many genes are known to be involved in the formation of tendon. However, their functional roles in tendon development have not been fully characterized. Tissue engineers have attempted to generate functional tendon tissue in vitro. However, a lack of knowledge of normal tendon development has hampered these efforts. Here we review studies focusing on the developmental mechanisms of tendon development, and discuss the potential applications of a molecular understanding of tendon development to the treatment of tendon injuries. PMID:21314435

  11. Rotator cuff repair augmentation in a rat model that combines a multilayer xenograft tendon scaffold with bone marrow stromal cells

    PubMed Central

    Omi, Rei; Gingery, Anne; Steinmann, Scott P.; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng

    2016-01-01

    Hypothesis A composite of multilayer tendon slices (COMTS) seeded with bone marrow stromal cells (BMSCs) may impart mechanical and biologic augmentation effects on supraspinatus tendon repair under tension, thereby improving the healing process after surgery in rats. Methods Adult female Lewis rats (n = 39) underwent transection of the supraspinatus tendon and a 2-mm tendon resection at the distal end, followed by immediate repair to its bony insertion site under tension. Animals received 1 of 3 treatments at the repair site: (1) no augmentation, (2) COMTS augmentation alone, or (3) BMSC-seeded COMTS augmentation. BMSCs were labeled with a fluorescent cell marker. Animals were euthanized 6 weeks after surgery, and the extent of healing of the repaired supraspinatus tendon was evaluated with biomechanical testing and histologic analysis. Results Histologic analysis showed gap formation between the repaired tendon and bone in all specimens, regardless of treatment. Robust fibrous tissue was observed in rats with BMSC-seeded COMTS augmentation; however, fibrous tissue was scarce within the gap in rats with no augmentation or COMTS-only augmentation. Labeled transplanted BMSCs were observed throughout the repair site. Biomechanical analysis showed that the repairs augmented with BMSC-seeded COMTS had significantly greater ultimate load to failure and stiffness compared with other treatments. However, baseline (time 0) data showed that COMTS-only augmentation did not increase mechanical strength of the repair site. Conclusion Although the COMTS scaffold did not increase the initial repair strength, the BMSC-seeded scaffold increased healing strength and stiffness 6 weeks after rotator cuff repair in a rat model. Level of evidence Basic Science Study, Animal Model. PMID:26387915

  12. Scaffolds in Tendon Tissue Engineering

    PubMed Central

    Longo, Umile Giuseppe; Lamberti, Alfredo; Petrillo, Stefano; Maffulli, Nicola; Denaro, Vincenzo

    2012-01-01

    Tissue engineering techniques using novel scaffold materials offer potential alternatives for managing tendon disorders. Tissue engineering strategies to improve tendon repair healing include the use of scaffolds, growth factors, cell seeding, or a combination of these approaches. Scaffolds have been the most common strategy investigated to date. Available scaffolds for tendon repair include both biological scaffolds, obtained from mammalian tissues, and synthetic scaffolds, manufactured from chemical compounds. Preliminary studies support the idea that scaffolds can provide an alternative for tendon augmentation with an enormous therapeutic potential. However, available data are lacking to allow definitive conclusion on the use of scaffolds for tendon augmentation. We review the current basic science and clinical understanding in the field of scaffolds and tissue engineering for tendon repair. PMID:22190961

  13. Does partial tear repair of adjacent tendons improve the outcome of supraspinatus tendonfull-thickness tear reinsertion?

    PubMed

    Nich, C; Dhiaf, N; Di Schino, M; Augereau, B

    2014-11-01

    Partial tearing of the infraspinatus and/or subscapularis tendon(s) is frequently associated with supraspinatus full-thickness tears. However, limited data regarding its influence on supraspinatus surgical repair is available. Our aim was to assess the functional and anatomical outcomes of open repair of supraspinatus full-thickness tears combined with adjacent partial tearing, comparatively to a control. We retrospectively identified 22 patients (22 shoulders) with a partial tear, most of them being a delamination tear, of the infraspinatus and/or subscapularis tendons associated with a complete detachment of the supraspinatus tendon. Twenty-seven patients (27 shoulders) treated for an isolated complete detachment of the supraspinatus tendon by open repair served as controls. The mean age was 58 years. A proximalized trans-osseous reinsertion of the supraspinatus tendon was combined with a curettage-closure of the delamination tear. Patients were evaluated with standardized MRI at last follow-up. At a mean of 75-month follow-up, the presence of a partial tear of either infraspinatus or subscapularis, or both, did not influence function and healing rates of supraspinatus tendon repair. Conversely to the control, when a retear occurred, the functional score tended to worsen. Preoperatively, fatty muscular degeneration was more pronounced when a partial tear was present. Fatty degeneration worsened regardless of repair healing. Open reinsertion of a supraspinatus full-thickness tear associated with a thorough treatment of partial tear of adjacent tendons led to optimal functional and anatomical mid term outcomes. Our results suggest the presence of a partial tear of adjacent tendons could be associated with poorer function in case of supraspinatus tendon re-rupture. Level III case-control study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  14. Sonographically guided percutaneous needle tenotomy for treatment of common extensor tendinosis in the elbow.

    PubMed

    McShane, John M; Nazarian, Levon N; Harwood, Marc I

    2006-10-01

    Chronic tendinosis of the common extensor tendon of the lateral elbow can be a difficult problem to treat. We report our experience with sonographically guided percutaneous needle tenotomy to relieve pain and improve function in patients with this condition. We performed sonographically guided percutaneous needle tenotomy on 58 consecutive patients who had persistent pain and disability resulting from common extensor tendinosis. Under a local anesthetic and sonographic guidance, a needle was advanced into the common extensor tendon, and the tip of the needle was used to repeatedly fenestrate the tendinotic tissue. Calcifications, if present, were mechanically fragmented, and the adjacent bony surface of the apex and face of the epicondyle were abraded. Finally, the fenestrated tendon was infiltrated with a solution containing corticosteroid mixed with bupivacaine. After the procedure, patients were instructed to perform passive stretches and to undergo physical therapy. During a subsequent telephone interview, patients answered questions about their experience, their functioning level, and their perceptions of procedure outcome. Fifty-five (95%) of 58 patients were contacted by telephone and agreed to participate in the study. Thirty-five (63.6%) of 55 respondents reported excellent outcomes, 16.4% good, 7.3% fair, and 12.7% poor. The average follow-up time from the date of the procedure to the date of the interview was 28 months (range, 17-44 months). No adverse events were reported; 85.5% stated that they would refer a friend or close relative for the procedure. Sonographically guided percutaneous needle tenotomy for lateral elbow tendinosis is a safe, effective, and viable alternative for patients in whom all other nonsurgical treatments failed.

  15. New Developments Are Improving Flexor Tendon Repair.

    PubMed

    Tang, Jin Bo

    2018-06-01

    New developments in primary tendon repair in recent decades include stronger core tendon repair techniques, judicious and adequate venting of critical pulleys, followed by a combination of passive and active digital flexion and extension. During repair, core sutures over the tendon should have sufficient suture purchase (no shorter than 0.7 to 1 cm) in each tendon end and must be sufficiently tensioned to resist loosening and gap formation between tendon ends. Slight or even modest bulkiness in the tendon substance at the repair site is not harmful, although marked bulkiness should always be avoided. To expose the tendon ends and reduce restriction to tendon gliding, the longest annular pulley in the fingers (i.e., the A2 pulley) can be vented partially with an incision over its distal or proximal sheath no longer than 1.5 to 2 cm; the annular pulley over the middle phalanx (i.e., the A4 pulley) can be vented entirely. Surgeons have not observed adverse effects on hand function after judicious and limited venting. The digital extension-flexion test to check the quality of the repair during surgery has become increasingly routine. A wide-awake surgical setting allows patient to actively move the digits. After surgery, surgeons and therapists protect patients with a short splint and flexible wrist positioning, and are now moving toward out-of-splint freer early active motion. Improved outcomes have been reported over the past decade with minimal or no rupture during postoperative active motion, along with lower rates of tenolysis.

  16. Atelocollagen Enhances the Healing of Rotator Cuff Tendon in Rabbit Model.

    PubMed

    Suh, Dong-Sam; Lee, Jun-Keun; Yoo, Ji-Chul; Woo, Sang-Hun; Kim, Ga-Ram; Kim, Ju-Won; Choi, Nam-Yong; Kim, Yongdeok; Song, Hyun-Seok

    2017-07-01

    Failure of rotator cuff healing is a common complication despite the rapid development of surgical repair techniques for the torn rotator cuff. To verify the effect of atelocollagen on tendon-to-bone healing in the rabbit supraspinatus tendon compared with conventional cuff repair. Controlled laboratory study. A tear of the supraspinatus tendon was created and repaired in 46 New Zealand White rabbits. They were then randomly allocated into 2 groups (23 rabbits per group; 15 for histological and 8 for biomechanical test). In the experimental group, patch-type atelocollagen was implanted between bone and tendon during repair; in the control group, the torn tendon was repaired without atelocollagen. Each opposite shoulder served as a sham (tendon was exposed only). Histological evaluation was performed at 4, 8, and 12 weeks. Biomechanical tensile strength was tested 12 weeks after surgery. Histological evaluation scores of the experimental group (4.0 ± 1.0) were significantly superior to those of the control group (7.7 ± 2.7) at 12 weeks ( P = .005). The load to failure was significantly higher in the experimental group (51.4 ± 3.9 N) than in the control group (36.4 ± 5.9 N) ( P = .001). Histological and biomechanical studies demonstrated better results in the experimental group using atelocollagen in a rabbit model of the supraspinatus tendon tear. Atelocollagen patch could be used in the cuff repair site to enhance healing.

  17. Cyclic Testing of the 6-Strand Tang and Modified Lim-Tsai Flexor Tendon Repair Techniques.

    PubMed

    Kang, Gavrielle Hui-Ying; Wong, Yoke-Rung; Lim, Rebecca Qian-Ru; Loke, Austin Mun-Kitt; Tay, Shian-Chao

    2018-03-01

    In this study, we compared the Tang repair technique with the 6-strand modified Lim-Tsai repair technique under cyclic testing conditions. Twenty fresh-frozen porcine flexor tendons were randomized into 2 groups for repair with either the modified Lim-Tsai or the Tang technique using Supramid 4-0 core sutures and Ethilon 6-0 epitendinous running suture. The repaired tendons were subjected to 2 stage cyclic loading. The survival rate and gap formation at the repair site were recorded. Tendons repaired by the Tang technique achieved an 80% survival rate. None of the modified Lim-Tsai repairs survived. The mean gap formed at the end of 1000 cycles was 1.09 mm in the Tang repairs compared with 4.15 mm in the modified Lim-Tsai repairs. The Tang repair is biomechanically stronger than the modified Lim-Tsai repair under cyclic loading. The Tang repair technique may exhibit a higher tolerance for active mobilization after surgery with less propensity for gap formation. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. [Flexor tendon repair: a short story].

    PubMed

    Moutet, F; Corcella, D; Forli, A; Mesquida, V

    2014-12-01

    This short story of flexor tendon repair aims to illustrate hesitations and wanderings of this surgery. Obviously tendon repair was very early considered, but it developed and diffused rather lately. It became a routine practice only in 20th century. This was due on the one hand, in Occident, to the Galen's dogmatic interdiction, on the other hand, to the repair difficulties of this paradoxical structure. Actually tendon is made of fibroblasts and collagen (sticky substances), and then its only goal is to move. According to this necessity, whatever the used techniques are, gliding is the final purpose. Technical evolutions are illustrated by historical contributions to flexor tendon surgery of several "giants" of hand surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. Joint capsule attachment to the extensor carpi radialis brevis origin: an anatomical study with possible implications regarding the etiology of lateral epicondylitis.

    PubMed

    Nimura, Akimoto; Fujishiro, Hitomi; Wakabayashi, Yoshiaki; Imatani, Junya; Sugaya, Hiroyuki; Akita, Keiichi

    2014-02-01

    To identify the unique anatomical characteristic of the extensor carpi radialis brevis (ECRB) origin and points of differentiation from other extensors and to clarify the specific relationship of the ECRB to the underlying structures. We studied the origin of each extensor macroscopically for its muscular and tendinous parts; to identify the relationship between the ECRB origin and the deeper structures, we also examined the attachment of the joint capsule under the ECRB origin. The ECRB simply originated as a tendon without any muscle, whereas other extensors originated as a mixture of tendon and muscle. At the anterior part of the ECRB origin, the thin attachment of the joint capsule (average width, 3.3 mm) lay deep to the ECRB and was distinct. However, at the posterodistal portion, the joint capsule, annular ligament, and supinator were intermingled and originated as a single wide sheet from the humerus (average width, 10.7 mm). The anterior part of the ECRB origin was delicate, because the ECRB origin was purely tendinous, and the attachment of the articular capsule was thin compared with that of the posterodistal attachment. This thin attachment could be an initial factor leading to the development of lateral epicondylitis. The results of the current study may enhance magnetic resonance imaging understanding and may help clarify the etiology of the lateral epicondylitis. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs

    PubMed Central

    Dorweiler, Matthew A.; Van Dyke, Rufus O.; Siska, Robert C.; Boin, Michael A.; DiPaola, Mathew J.

    2017-01-01

    Background: Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. Hypothesis: The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Study Design: Controlled laboratory study. Methods: Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. Results: The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º (P = .75) or 90º (P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference (P = .28). Conclusion: Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. Clinical Relevance: This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures. PMID:28607942

  1. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs.

    PubMed

    Dorweiler, Matthew A; Van Dyke, Rufus O; Siska, Robert C; Boin, Michael A; DiPaola, Mathew J

    2017-05-01

    Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Controlled laboratory study. Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º ( P = .75) or 90º ( P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference ( P = .28). Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures.

  2. Kinesthetic perception based on integration of motor imagery and afferent inputs from antagonistic muscles with tendon vibration.

    PubMed

    Shibata, E; Kaneko, F

    2013-04-29

    The perceptual integration of afferent inputs from two antagonistic muscles, or the perceptual integration of afferent input and motor imagery are related to the generation of a kinesthetic sensation. However, it has not been clarified how, or indeed whether, a kinesthetic perception would be generated by motor imagery if afferent inputs from two antagonistic muscles were simultaneously induced by tendon vibration. The purpose of this study was to investigate how a kinesthetic perception would be generated by motor imagery during co-vibration of the two antagonistic muscles at the same frequency. Healthy subjects participated in this experiment. Illusory movement was evoked by tendon vibration. Next, the subjects imaged wrist flexion movement simultaneously with tendon vibration. Wrist flexor and extensor muscles were vibrated according to 4 patterns such that the difference between the two vibration frequencies was zero. After each trial, the perceived movement sensations were quantified on the basis of the velocity and direction of the ipsilateral hand-tracking movements. When the difference in frequency applied to the wrist flexor and the extensor was 0Hz, no subjects perceived movements without motor imagery. However, during motor imagery, the flexion velocity of the perceived movement was higher than the flexion velocity without motor imagery. This study clarified that the afferent inputs from the muscle spindle interact with motor imagery, to evoke a kinesthetic perception, even when the difference in frequency applied to the wrist flexor and extensor was 0Hz. Furthermore, the kinesthetic perception resulting from integrations of vibration and motor imagery increased depending on the vibration frequency to the two antagonistic muscles. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Functional anatomy and muscle moment arms of the pelvic limb of an elite sprinting athlete: the racing greyhound (Canis familiaris)

    PubMed Central

    Williams, S B; Wilson, A M; Rhodes, L; Andrews, J; Payne, R C

    2008-01-01

    We provide quantitative anatomical data on the muscle–tendon architecture and geometry of the pelvic limb of an elite sprint athlete, the racing greyhound. Specifically, muscle masses, muscle lengths, fascicle lengths, pennation angles and muscle moment arms were measured. Maximum isometric force and power of muscles, the maximum muscle torque at joints and tendon stress and strain were estimated. We compare data with that published for a generalized breed of canid, and other cursorial mammals such as the horse and hare. The pelvic limb of the racing greyhound had a relatively large volume of hip extensor muscle, which is likely to be required for power production. Per unit body mass, some pelvic limb muscles were relatively larger than those in less specialized canines, and many hip extensor muscles had longer fascicle lengths. It was estimated that substantial extensor moments could be created about the tarsus and hip of the greyhound allowing high power output and potential for rapid acceleration. The racing greyhound hence possesses substantial specializations for enhanced sprint performance. PMID:18657259

  4. Functional anatomy and muscle moment arms of the pelvic limb of an elite sprinting athlete: the racing greyhound (Canis familiaris).

    PubMed

    Williams, S B; Wilson, A M; Rhodes, L; Andrews, J; Payne, R C

    2008-10-01

    We provide quantitative anatomical data on the muscle-tendon architecture and geometry of the pelvic limb of an elite sprint athlete, the racing greyhound. Specifically, muscle masses, muscle lengths, fascicle lengths, pennation angles and muscle moment arms were measured. Maximum isometric force and power of muscles, the maximum muscle torque at joints and tendon stress and strain were estimated. We compare data with that published for a generalized breed of canid, and other cursorial mammals such as the horse and hare. The pelvic limb of the racing greyhound had a relatively large volume of hip extensor muscle, which is likely to be required for power production. Per unit body mass, some pelvic limb muscles were relatively larger than those in less specialized canines, and many hip extensor muscles had longer fascicle lengths. It was estimated that substantial extensor moments could be created about the tarsus and hip of the greyhound allowing high power output and potential for rapid acceleration. The racing greyhound hence possesses substantial specializations for enhanced sprint performance.

  5. Tension Regulation at the Suture Lines for Repair of Neglected Achilles Tendon Laceration.

    PubMed

    Massoud, Elsayed Ibraheem Elsayed

    2017-03-01

    Operative intervention is the preferred option for management of the neglected laceration of the Achilles tendon. However, the commonly used techniques rarely follow the principles of the regenerative medicine for the restoration of the lost tissue. This study postulated that incorporation of the autogenous tendon graft would properly progress when the interplay between mechanical loading and healing phases was correctly applied. A prospective study included 15 patients who were treated for neglected Achilles tendon laceration using the technique of lengthening of the proximal tendon stump. An absorbable reinforcement suture was used for control of the mechanical environment at the suture lines. By an average 5 years of the prospective follow-up, all the repaired tendons had restored continuity and length. The calf circumference equalized to the uninjured side in 12 patients. However, 3 patients had calf atrophy but they improved compared to the preoperative measurements. Sonogram confirmed the restoration of the normal thickness and the gliding characteristics of the repaired tendon. The technique restored continuity and tension of the repaired tendon, preserved the calf circumference, and prevented peritendinous adhesions. The absorbable reinforcement suture spontaneously allowed for the mechanical loading of the grafted tendon. Level IV, case series.

  6. Objective assessment of surgical training in flexor tendon repair: the utility of a low-cost porcine model as demonstrated by a single-subject research design.

    PubMed

    Zetlitz, Elisabeth; Wearing, Scott Cameron; Nicol, Alexander; Hart, Andrew Mackay

    2012-01-01

    This study evaluated the utility of a porcine flexor tendon model and standard biomechanical testing procedures to quantify the acquisition of surgical skills associated with Zone II flexor tendon repair in a trainee by benchmarking task performance outcomes relative to evidence-based standards. Single-subject repeated measures research design. Bench-top set-up of apparatus undertaken in a University Research laboratory. After initial directed learning, a trainee repaired 70 fresh flexor digitorum profundus tendons within the flexor sheath using either a Pennington or ventral-locking-loop modification of a two-strand Kessler core repair. Tendon repairs were then preconditioned and distracted to failure. Key biomechanical parameters of the repair, including the ultimate tensile strength (UTS), yield strength, 3 mm gap force and stiffness, were calculated. Repairs were divided into 3 categories, early (first 10 days), intermediate (ensuing 10 days), and late repairs (final 10 days), and potential changes in repair properties over the training period were evaluated using a general linear modeling approach. There was a significant change in the mechanical characteristics of the repairs over the training period, evidencing a clear learning effect (p < 0.05). Irrespective of the repair technique employed, early and intermediate repairs were characterized by a significantly lower UTS (29% and 20%, respectively), 3 mm gap (21% and 16%, respectively), and yield force (18% and 23%, respectively), but had a higher stiffness (33% and 38%, respectively) than late repairs (p < 0.05). The UTS of late repairs (47-48 N) were comparable to those published within the literature (45-51 N), suggesting surgical competence of the trainee. This simple, low-cost porcine model appears to be useful for providing preclinical training in flexor tendon repair techniques and has the potential to provide a quantitative index to evaluate the competency of surgical trainees. Further research is now required to identify optimal training parameters for flexor tendon repair and to develop procedure-specific standards for adequate benchmarking. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  7. The Effects of Bio-Lubricating Molecules on Flexor Tendon Reconstruction in A Canine Allograft Model In Vivo

    PubMed Central

    Zhao, Chunfeng; Wei, Zhuang; Kirk, Ramona L.; Thoreson, Andrew R.; Jay, Gregory D.; Moran, Steven L.; An, Kai-Nan; Amadio, Peter C.

    2014-01-01

    Background Using allograft is an attractive alternative for flexor tendon reconstruction because of the lack of donor morbidity, and better matching to the intrasynovial environment. The purpose of this study was to use biolubricant molecules to modify the graft surface to decrease adhesions and improve digit function. Methods 28 flexor digitorum profundus (FDP) tendons from the 2nd and 5th digits of 14 dogs were first lacerated and repaired to create a model with repair failure and scar digit for tendon reconstruction. Six weeks after the initial surgery, the tendons were reconstructed with FDP allograft tendons obtained from canine cadavers. One graft tendon in each dog was treated with saline as a control and the other was treated with gelatin, carbodiimide derivatized, hyaluronic acid and lubricin (cd-HA-Lubricin). Six weeks postoperatively, digit function, graft mechanics, and biology were analyzed. Results Allograft tendons treated with cd-HA-Lubricin had decreased adhesions at the proximal tendon/graft repair and within flexor sheath, improved digit function, and increased graft gliding ability. The treatment also reduced the strength at the distal tendon to bone repair, but the distal attachment rupture rate was similar for both graft types. Histology showed that viable cells migrated to the allograft, but these were limited to the tendon surface. Conclusion cd-HA-Lubricin treatment of tendon allograft improves digit functional outcomes after flexor tendon reconstruction. However, delayed bone-tendon healing should be a caution. Furthermore, the cell infiltration into the allograft tendons substance should be a target for future studies, to shorten the allograft self-regeneration period. PMID:24445876

  8. Step Cut Lengthening: A Technique for Treatment of Flexor Pollicis Longus Tendon Rupture.

    PubMed

    Chong, Chew-Wei; Chen, Shih-Heng

    2018-04-01

    Reconstruction of a tendon defect is a challenging task in hand surgery. Delayed repair of a ruptured flexor pollicis longus (FPL) tendon is often associated with tendon defect. Primary repair of the tendon is often not possible, particularly after debridement of the unhealthy segment of the tendon. As such, various surgical treatments have been described in the literature, including single-stage tendon grafting, 2-stage tendon grafting, flexor digitorum superficialis tendon transfer from ring finger, and interphalangeal joint arthrodesis. We describe step cut lengthening of FPL tendon for the reconstruction of FPL rupture. This is a single-stage reconstruction without the need for tendon grafting or tendon transfer. To our knowledge, no such technique has been previously described.

  9. Nonsurgical treatment and early return to activity leads to improved Achilles tendon fatigue mechanics and functional outcomes during early healing in an animal model.

    PubMed

    Freedman, Benjamin R; Gordon, Joshua A; Bhatt, Pankti R; Pardes, Adam M; Thomas, Stephen J; Sarver, Joseph J; Riggin, Corinne N; Tucker, Jennica J; Williams, Alexis W; Zanes, Robert C; Hast, Michael W; Farber, Daniel C; Silbernagel, Karin G; Soslowsky, Louis J

    2016-12-01

    Achilles tendon ruptures are common and devastating injuries; however, an optimized treatment and rehabilitation protocol has yet to be defined. Therefore, the objective of this study was to investigate the effects of surgical repair and return to activity on joint function and Achilles tendon properties after 3 weeks of healing. Sprague-Dawley rats (N = 100) received unilateral blunt transection of their Achilles tendon. Animals were then randomized into repaired or non-repaired treatments, and further randomized into groups that returned to activity after 1 week (RTA1) or after 3 weeks (RTA3) of limb casting in plantarflexion. Limb function, passive joint mechanics, and tendon properties (mechanical, organizational using high frequency ultrasound, histological, and compositional) were evaluated. Results showed that both treatment and return to activity collectively affected limb function, passive joint mechanics, and tendon properties. Functionally, RTA1 animals had increased dorsiflexion ROM and weight bearing of the injured limb compared to RTA3 animals 3-weeks post-injury. Such functional improvements in RTA1 tendons were evidenced in their mechanical fatigue properties and increased cross sectional area compared to RTA3 tendons. When RTA1 was coupled with nonsurgical treatment, superior fatigue properties were achieved compared to repaired tendons. No differences in cell shape, cellularity, GAG, collagen type I, or TGF-β staining were identified between groups, but collagen type III was elevated in RTA3 repaired tendons. The larger tissue area and increased fatigue resistance created in RTA1 tendons may prove critical for optimized outcomes in early Achilles tendon healing following complete rupture. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2172-2180, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. Nonsurgical treatment and early return to activity leads to improved Achilles tendon fatigue mechanics and functional outcomes during early healing in an animal model

    PubMed Central

    Freedman, BR; Gordon, JA; Bhatt, PB; Pardes, AM; Thomas, SJ; Sarver, JJ; Riggin, CN; Tucker, JJ; Williams, AW; Zanes, RC; Hast, MW; Farber, DC; Silbernagel, KG; Soslowsky, LJ

    2016-01-01

    Achilles tendon ruptures are common and devastating injuries; however, an optimized treatment and rehabilitation protocol has yet to be defined. Therefore, the objective of this study was to investigate the effects of surgical repair and return to activity on joint function and Achilles tendon properties after 3-weeks of healing. Sprague Dawley rats (N=100) received unilateral blunt transection of their Achilles tendon. Animals were then randomized into repaired or non-repaired treatments, and further randomized into groups that returned to activity after 1-week (RTA1) or after 3-weeks (RTA3) of limb casting in plantarflexion. Limb function, passive joint mechanics, and tendon properties (mechanical, organizational using high frequency ultrasound, histological, and compositional) were evaluated. Results showed that both treatment and return to activity collectively affected limb function, passive joint mechanics, and tendon properties. Functionally, RTA1 animals had increased dorsiflexion ROM and weight bearing of the injured limb compared to RTA3 animals 3-weeks post injury. Such functional improvements in RTA1 tendons were evidenced in their mechanical fatigue properties and increased cross sectional area compared to RTA3 tendons. When RTA1 was coupled with nonsurgical treatment, superior fatigue properties were achieved compared to repaired tendons. No differences in cell shape, cellularity, GAG, collagen type I, or TGF-β staining were identified between groups, but collagen type III was elevated in RTA3 repaired tendons. The larger tissue area and increased fatigue resistance created in RTA1 tendons may prove critical for optimized outcomes in early Achilles tendon healing following complete rupture. PMID:27038306

  11. Tendon biomechanics and mechanobiology - a mini-review of basic concepts and recent advancements

    PubMed Central

    Wang, James H-C.; Guo, Qianping; Li, Bin

    2011-01-01

    Due to their unique hierarchical structure and composition, tendons possess characteristic biomechanical properties, including high mechanical strength and viscoelasticity, which enable them to carry and transmit mechanical loads (muscular forces) effectively. Tendons are also mechano-responsive by adaptively changing their structure and function in response to altered mechanical loading conditions. In general, mechanical loading at physiological levels is beneficial to tendons, but excessive loading or disuse of tendons is detrimental. This mechano-adaptability is due to the cells present in tendons. Tendon fibroblasts (tenocytes) are the dominant tendon cells responsible for tendon homeostasis and repair. Tendon stem cells (TSCs), which were recently discovered, also play a vital role in tendon maintenance and repair by virtue of their ability to self-renew and differentiate into tenocytes. TSCs may also be responsible for chronic tendon injury, or tendinopathy, by undergoing aberrant differentiation into non-tenocytes in response to excessive mechanical loading. Thus, it is necessary to devise optimal rehabilitation protocols in order to enhance tendon healing while reducing scar tissue formation and tendon adhesions. Moreover, along with scaffolds that can mimic tendon matrix environments and platelet-rich plasma (PRP), which serves as a source of growth factors, TSCs may be the optimal cell type for enhancing repair of injured tendons. PMID:21925835

  12. Tendon biomechanics and mechanobiology--a minireview of basic concepts and recent advancements.

    PubMed

    Wang, James H-C; Guo, Qianping; Li, Bin

    2012-01-01

    Due to their unique hierarchical structure and composition, tendons possess characteristic biomechanical properties, including high mechanical strength and viscoelasticity, which enable them to carry and transmit mechanical loads (muscular forces) effectively. Tendons are also mechanoresponsive by adaptively changing their structure and function in response to altered mechanical loading conditions. In general, mechanical loading at physiological levels is beneficial to tendons, but excessive loading or disuse of tendons is detrimental. This mechanoadaptability is due to the cells present in tendons. Tendon fibroblasts (tenocytes) are the dominant tendon cells responsible for tendon homeostasis and repair. Tendon stem cells (TSCs), which were recently discovered, also play a vital role in tendon maintenance and repair by virtue of their ability to self-renew and differentiate into tenocytes. TSCs may also be responsible for chronic tendon injury, or tendinopathy, by undergoing aberrant differentiation into nontenocytes in response to excessive mechanical loading. Thus, it is necessary to devise optimal rehabilitation protocols to enhance tendon healing while reducing scar tissue formation and tendon adhesions. Moreover, along with scaffolds that can mimic tendon matrix environments and platelet-rich plasma, which serves as a source of growth factors, TSCs may be the optimal cell type for enhancing repair of injured tendons. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  13. Re-rupture rate of primarily repaired distal biceps tendon injuries.

    PubMed

    Hinchey, John W; Aronowitz, Jessica G; Sanchez-Sotelo, Joaquin; Morrey, Bernard F

    2014-06-01

    Distal biceps tendon rupture is a common injury, and primary repair results in excellent return of function and strength. Complications resulting from distal biceps tendon repairs are well reported, but the incidence of re-ruptures has never been investigated. A search of the Mayo Clinic's Medical/Surgical Index was performed, and all distal biceps tendon repairs from January 1981 through May 2009 were identified. All patients who completed 12 months or more of follow-up were included. All charts were reviewed and patients contacted as necessary to identify a re-rupture. We also investigated the situation causing the re-rupture. We identified a total of 190 distal biceps tendon ruptures that underwent repair and met our inclusion and exclusion criteria. Of the 190 repairs, 172 (90.5%) were performed by the Mayo modification of the Boyd-Anderson 2-incision technique. Bilateral ruptures occurred in 13 patients (7.3%). Six primary ruptures (3.2%) occurred in women, 4 of the 6 being partial ruptures. Partial ruptures were found to be statistically more common than complete ruptures in women (P = .05). We identified 3 re-ruptures (1.5%), all occurring within 3 weeks of the index surgery. The re-rupture rate after primary repair of the distal biceps tendon is low at 1.5% and occurs within 3 weeks of index repair. This appears to be due to patient compliance and excessive force placed on repairs. We also found the incidence of women who sustain a distal biceps tendon tear to be 3.2%, with partial tears being statistically more common than complete ruptures. Level IV, case series, treatment study Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  14. Do postoperative platelet-rich plasma injections accelerate early tendon healing and functional recovery after arthroscopic supraspinatus repair? A randomized controlled trial.

    PubMed

    Wang, Allan; McCann, Philip; Colliver, Jess; Koh, Eamon; Ackland, Timothy; Joss, Brendan; Zheng, Minghao; Breidahl, Bill

    2015-06-01

    Tendon-bone healing after rotator cuff repair directly correlates with a successful outcome. Biological therapies that elevate local growth-factor concentrations may potentiate healing after surgery. To ascertain whether postoperative and repeated application of platelet-rich plasma (PRP) to the tendon repair site improves early tendon healing and enhances early functional recovery after double-row arthroscopic supraspinatus repair. Randomized controlled trial; Level of evidence, 1. A total of 60 patients underwent arthroscopic double-row supraspinatus tendon repair. After randomization, half the patients received 2 ultrasound-guided injections of PRP to the repair site at postoperative days 7 and 14. Early structural healing was assessed with MRI at 16 weeks, and cuff appearances were graded according to the Sugaya classification. Functional scores were recorded with the Oxford Shoulder Score; Quick Disability of the Arm, Shoulder and Hand; visual analog scale for pain; and Short Form-12 quality-of-life score both preoperatively and at postoperative weeks 6, 12, and 16; isokinetic strength and active range of motion were measured at 16 weeks. PRP treatment did not improve early functional recovery, range of motion, or strength or influence pain scores at any time point after arthroscopic supraspinatus repair. There was no difference in structural integrity of the supraspinatus repair on MRI between the PRP group (0% full-thickness retear; 23% partial tear; 77% intact) and the control group (7% full-thickness retear; 23% partial tear; 70% intact) at 16 weeks postoperatively (P = .35). After arthroscopic supraspinatus tendon repair, image-guided PRP treatment on 2 occasions does not improve early tendon-bone healing or functional recovery. © 2015 The Author(s).

  15. Augmentation of Distal Biceps Repair With an Acellular Dermal Graft Restores Native Biomechanical Properties in a Tendon-Deficient Model.

    PubMed

    Conroy, Christine; Sethi, Paul; Macken, Craig; Wei, David; Kowalsky, Marc; Mirzayan, Raffy; Pauzenberger, Leo; Dyrna, Felix; Obopilwe, Elifho; Mazzocca, Augustus D

    2017-07-01

    The majority of distal biceps tendon injuries can be repaired in a single procedure. In contrast, complete chronic tears with severe tendon substance deficiency and retraction often require tendon graft augmentation. In cases with extensive partial tears of the distal biceps, a human dermal allograft may be used as an alternative to restore tendon thickness and biomechanical integrity. Dermal graft augmentation will improve load to failure compared with nonaugmented repair in a tendon-deficient model. Controlled laboratory study. Thirty-six matched specimens were organized into 1 of 4 groups: native tendon, native tendon with dermal graft augmentation, tendon with an attritional defect, and tendon with an attritional defect repaired with a graft. To mimic a chronic attritional biceps lesion, a defect was created by a complete tear, leaving 30% of the tendon's width intact. The repair technique in all groups consisted of cortical button and interference screw fixation. All specimens underwent cyclical loading for 3000 cycles and were then tested to failure; gap formation and peak load at failure were documented. The mean (±SD) load to failure (320.9 ± 49.1 N vs 348.8 ± 77.6 N, respectively; P = .38) and gap formation (displacement) (1.8 ± 1.4 mm vs 1.6 ± 1.1 mm, respectively; P = .38) did not differ between the native tendon groups with and without graft augmentation. In the tendon-deficient model, the mean load to failure was significantly improved with graft augmentation compared with no graft augmentation (282.1 ± 83.8 N vs 199.7 ± 45.5 N, respectively; P = .04), while the mean gap formation was significantly reduced (1.2 ± 1.0 mm vs 2.7 ± 1.4 mm, respectively; P = .04). The mean load to failure of the deficient tendon with graft augmentation (282.1 N) compared with the native tendon (348.8 N) was not significantly different ( P = .12). This indicates that the native tendon did not perform differently from the grafted deficient tendon. In a tendon-deficient, complete distal biceps rupture model, acellular dermal allograft augmentation restored the native tendon's biomechanical properties at time zero. The grafted tissue-deficient model demonstrated no significant differences in the load to failure and gap formation compared with the native tendon. As expected, dermal augmentation of attritional tendon repair increased the load to failure and stiffness as well as decreased displacement compared with the ungrafted tissue-deficient model. Tendons with their native width showed no statistical difference or negative biomechanical consequences of dermal augmentation. Dermal augmentation of the distal biceps is a biomechanically feasible option for patients with an attritionally thinned-out tendon.

  16. Treatment of peroneal nerve injuries with simultaneous tendon transfer and nerve exploration.

    PubMed

    Ho, Bryant; Khan, Zubair; Switaj, Paul J; Ochenjele, George; Fuchs, Daniel; Dahl, William; Cederna, Paul; Kung, Theodore A; Kadakia, Anish R

    2014-08-06

    Common peroneal nerve palsy leading to foot drop is difficult to manage and has historically been treated with extended bracing with expectant waiting for return of nerve function. Peroneal nerve exploration has traditionally been avoided except in cases of known traumatic or iatrogenic injury, with tendon transfers being performed in a delayed fashion after exhausting conservative treatment. We present a new strategy for management of foot drop with nerve exploration and concomitant tendon transfer. We retrospectively reviewed a series of 12 patients with peroneal nerve palsies that were treated with tendon transfer from 2005 to 2011. Of these patients, seven were treated with simultaneous peroneal nerve exploration and repair at the time of tendon transfer. Patients with both nerve repair and tendon transfer had superior functional results with active dorsiflexion in all patients, compared to dorsiflexion in 40% of patients treated with tendon transfers alone. Additionally, 57% of patients treated with nerve repair and tendon transfer were able to achieve enough function to return to running, compared to 20% in patients with tendon transfer alone. No patient had full return of native motor function resulting in excessive dorsiflexion strength. The results of our limited case series for this rare condition indicate that simultaneous nerve repair and tendon transfer showed no detrimental results and may provide improved function over tendon transfer alone.

  17. Long digital extensor tendon mineralization and cranial cruciate ligament rupture in a dog.

    PubMed

    Kennedy, Katie C; Perry, James A; Duncan, Colleen G; Duerr, Felix M

    2014-07-01

    To report clinical and histopathologic features of long digital extensor (LDE) tendon mineralization with concurrent cranial cruciate ligament (CCL) rupture in a dog. Case report. 1.5-year-old, male castrated, English bulldog mix weighing 31.5 kg. Pre- and postoperative orthogonal radiographs, arthroscopic evaluation, arthrotomy with en bloc surgical excision, and histopathologic analysis of the excised LDE tendon. There was radiographic evidence of mineralization in the region of the proximal LDE and stifle instability suggestive of CCL rupture. Arthroscopy, and subsequent arthrotomy, showed complete tearing of the CCL and an intact but grossly thickened LDE. No evidence of avulsion or bony proliferation associated with the LDE was appreciated. Tibial plateau leveling osteotomy (TPLO) and tenectomy of the LDE returned the dog to normal weight-bearing. No evidence of ectopic mineralization in the affected limb or similar clinical signs in the contralateral limb have been observed in 12 months follow-up. LDE tenectomy followed by stabilization of the stifle by TPLO resulted in a functional outcome. Mineralization without concurrent avulsion of the LDE has not been reported in dogs; however, posterolateral tendon injury in people has been linked to knee instability and cruciate ligament rupture. © Copyright 2014 by The American College of Veterinary Surgeons.

  18. The effect of platelet-rich fibrin matrix on rotator cuff tendon healing: a prospective, randomized clinical study.

    PubMed

    Rodeo, Scott A; Delos, Demetris; Williams, Riley J; Adler, Ronald S; Pearle, Andrew; Warren, Russell F

    2012-06-01

    There is a strong need for methods to improve the biological potential of rotator cuff tendon healing. Platelet-rich fibrin matrix (PRFM) allows delivery of autologous cytokines to healing tissue, and limited evidence suggests a positive effect of platelet-rich plasma on tendon biology. To evaluate the effect of platelet-rich fibrin matrix on rotator cuff tendon healing. Randomized controlled trial; Level of evidence, 2. Seventy-nine patients undergoing arthroscopic rotator cuff tendon repair were randomized intraoperatively to either receive PRFM at the tendon-bone interface (n = 40) or standard repair with no PRFM (n = 39). Standardized repair techniques were used for all patients. The postoperative rehabilitation protocol was the same in both groups. The primary outcome was tendon healing evaluated by ultrasound (intact vs defect at repair site) at 6 and 12 weeks. Power Doppler ultrasound was also used to evaluate vascularity in the peribursal, peritendinous, and musculotendinous and insertion site areas of the tendon and bone anchor site. Secondary outcomes included standardized shoulder outcome scales (American Shoulder and Elbow Surgeons [ASES] and L'Insalata) and strength measurements using a handheld dynamometer. Patients and the evaluator were blinded to treatment group. All patients were evaluated at minimum 1-year follow-up. A logistic regression model was used to predict outcome (healed vs defect) based on tear severity, repair type, treatment type (PRFM or control), and platelet count. Overall, there were no differences in tendon-to-bone healing between the PRFM and control groups. Complete tendon-to-bone healing (intact repair) was found in 24 of 36 (67%) in the PRFM group and 25 of 31 (81%) in the control group (P = .20). There were no significant differences in healing by ultrasound between 6 and 12 weeks. There were gradual increases in ASES and L'Insalata scores over time in both groups, but there were no differences in scores between the groups. We also found no difference in vascularity in the peribursal, peritendinous, and musculotendinous areas of the tendon between groups. There were no differences in strength between groups. Platelet count had no effect on healing. Logistic regression analysis demonstrated that PRFM was a significant predictor (P = .037) for a tendon defect at 12 weeks, with an odds ratio of 5.8. Platelet-rich fibrin matrix applied to the tendon-bone interface at the time of rotator cuff repair had no demonstrable effect on tendon healing, tendon vascularity, manual muscle strength, or clinical rating scales. In fact, the regression analysis suggests that PRFM may have a negative effect on healing. Further study is required to evaluate the role of PRFM in rotator cuff repair.

  19. Management of acute Achilles tendon rupture with tendon-bundle technique

    PubMed Central

    Li, Chun-Guang; Li, Bing

    2017-01-01

    Objective *These authors contributed equally to this work.To explore tendon-bundle technique for treating Achilles tendon rupture with no defects. Methods Patients with full unilateral Achilles tendon rupture with no defects were included. The Achilles tendon medial edge surgical repair approach was used, revealing horsetail-like rupture bundles. Tendon bundles were anatomically realigned and repaired end-to-end using 5-0 sutures. Patients were followed-up for 1 year, and assessed for differences between the repaired versus healthy limb. Results Out of 24 patients (18 male, 6 female; aged 19–56 years) at 1 year following surgery, mean American Orthopaedic Foot and Ankle Society score was 92.4 ± 5.9; mean differences between the surgically repaired versus contralateral side in dorsiflexion and plantarflexion angle were 3.5 ± 2.3° and 5.6 ± 3.2°, respectively; mean difference in calf circumference between the two sides was 0.9 ± 0.5 cm; and mean increase in Achilles tendon width versus the healthy side was 0.8 ± 0.2 cm. By 1 year post-surgery, there were no significant between-side differences in dorsiflexion and plantarflexion angle, or calf circumference. Conclusions Tendon-bundle surgery resulted in good ankle function restoration and low complication rates. Tendon-bundle surgery may reduce blood supply destruction and maximally preserve Achilles tendon length, and may be effective for treating Achilles tendon rupture with no defects. PMID:28222622

  20. Advanced age diminishes tendon-to-bone healing in a rat model of rotator cuff repair.

    PubMed

    Plate, Johannes F; Brown, Philip J; Walters, Jordan; Clark, John A; Smith, Thomas L; Freehill, Michael T; Tuohy, Christopher J; Stitzel, Joel D; Mannava, Sandeep

    2014-04-01

    Advanced patient age is associated with recurrent tearing and failure of rotator cuff repairs clinically; however, basic science studies have not evaluated the influence of aging on tendon-to-bone healing after rotator cuff repair in an animal model. Hypothesis/ This study examined the effect of aging on tendon-to-bone healing in an established rat model of rotator cuff repair using the aged animal colony from the National Institute on Aging of the National Institutes of Health. The authors hypothesized that normal aging decreases biomechanical strength and histologic organization at the tendon-to-bone junction after acute repair. Controlled laboratory study. In 56 F344xBN rats, 28 old and 28 young (24 and 8 months of age, respectively), the supraspinatus tendon was transected and repaired. At 2 or 8 weeks after surgery, shoulder specimens underwent biomechanical testing to compare load-to-failure and load-relaxation response between age groups. Histologic sections of the tendon-to-bone interface were assessed with hematoxylin and eosin staining, and collagen fiber organization was assessed by semiquantitative analysis of picrosirius red birefringence under polarized light. Peak failure load was similar between young and old animals at 2 weeks after repair (31% vs 26% of age-matched uninjured controls, respectively; P > .05) but significantly higher in young animals compared with old animals 8 weeks after repair (86% vs 65% of age-matched uninjured controls, respectively; P < .01). Eight weeks after repair, fibroblasts appeared more organized and uniformly aligned in young animals on hematoxylin and eosin slides compared with old animals. Collagen birefringence analysis of the tendon-to-bone junction demonstrated that young animals had increased collagen fiber organization and similar histologic structure compared with age-matched controls (53.7 ± 2.4 gray scales; P > .05). In contrast, old animals had decreased collagen fiber organization and altered structure compared with age-matched controls (49.8 ± 3.1 gray scales; P < .01). In a rat model of aging, old animals demonstrated diminished tendon-to-bone healing after rotator cuff injury and repair. Old animals had significantly decreased failure strength and collagen fiber organization at the tendon-to-bone junction compared with young animals. This study implies that animal age may need to be considered in future studies of rotator cuff repair in animal models. With increasing age and activity level of the population, the incidence of rotator cuff tears is predicted to rise. Despite advances in rotator cuff repair technique, the retear rate remains specifically high in elderly patients. The findings of this research suggest that aging negatively influences tendon-to-bone healing after rotator cuff repair in a validated animal model.

  1. Effects of PDGF-BB delivery from heparinized collagen sutures on the healing of lacerated chicken flexor tendon in vivo.

    PubMed

    Younesi, Mousa; Knapik, Derrick M; Cumsky, Jameson; Donmez, Baris Ozgur; He, Ping; Islam, Anowarul; Learn, Greg; McClellan, Philip; Bohl, Michael; Gillespie, Robert J; Akkus, Ozan

    2017-11-01

    Flexor tendon lacerations are traditionally repaired by using non-absorbable monofilament sutures. Recent investigations have explored to improve the healing process by growth factor delivery from the sutures. However, it is difficult to conjugate growth factors to nylon or other synthetic sutures. This study explores the performance of a novel electrochemically aligned collagen suture in a flexor tendon repair model with and without platelet derived growth factor following complete tendon laceration in vivo. Collagen suture was fabricated via electrochemical alignment process. Heparin was covalently bound to electrochemically aligned collagen sutures (ELAS) to facilitate affinity bound delivery of platelet-derived growth factor-BB (PDGF-BB). Complete laceration of the flexor digitorum profundus in the third digit of the foot was performed in 36 skeletally mature White Leghorn chickens. The left foot was used as the positive control. Animals were randomly divided into three groups: control specimens treated with standard nylon suture (n=12), specimens repaired with heparinated ELAS suture without PDGF-BB (n=12) and specimens repaired with heparinated ELAS suture with affinity bound PDGF-BB (n=12). Specimens were harvested at either 4weeks or 12weeks following tendon repair. Differences between groups were evaluated by the degree of gross tendon excursion, failure load/stress, stiffness/modulus, absorbed energy at failure, elongation/strain at failure. Quantitative histological scoring was performed to assess cellularity and vascularity. Closed flexion angle measurements demonstrated no significant differences in tendon excursion between the study groups at 4 or 12weeks. Biomechanical testing showed that the group treated with PDGF-BB bound heparinated ELAS suture had significantly higher stiffness and failure load (p<0.05) at 12-weeks relative to both heparinated ELAS suture and nylon suture. Similarly, the group treated with PDGF-BB bound suture had significantly higher ultimate tensile strength and Young's modulus (p<0.05) at 12-weeks relative to both ELAS suture and nylon suture. Compared to nylon controls, heparinized ELAS with PDGF-BB improved biomechanics and vascularity during tendon healing by 12-weeks following primary repair. The ability of ELAS to deliver PDGF-BB to the lacerated area of tendon presents investigators with a functional bioinductive platform to improve repair outcomes following flexor tendon repair. A high strength aligned collagen suture was fabricated via linear electrocompaction and heparinized for prolonged delivery of PDFG-BB. When it was used to suture a complete lacerated flexor tendon in a chicken model controlled release of the PDGF-BB improved the strength of treated tendon after 12 weeks compared to tendon sutured with commercial nylon suture. Furthermore, Collagen suture with affinity bound PDGF-BB enhanced the vascularization and remodeling of lacerated tendon when it compare to synthetic nylon suture. Overall, electrocompacted collagen sutures holds potential to improve repair outcome in flexor tendon surgeries by improving repair strength and stiffness, vascularity, and remodeling via sustained delivery of the PDGF-BB. The bioinductive collagen suture introduces a platform for sustained delivery of other growth factors for a wide-array of applications. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  2. [HEALING MODEL RESEARCH OF ROTATOR CUFF INJURY IN CANINE].

    PubMed

    Ye, Wei; Bao, Nirong; Zhaq, Jianning

    2016-04-01

    To compare the difference of rotator cuff healing between different types of injury andbetween different repair methods, and to explore the animal model to accurately simulate the restorative process afterrepair of rotator cuff injury. Twelve adult male beagle dogs (weighing, 10-15 kg) were divided into 3 groups (n = 4) according to different processing methods: acute rotator cuff injury+Mason-Allen suture repair (group A), huge rotator cuff injury+Mason-Allen suture repair (group B), and huge rotator cuff injury+Mason-Allen combined with autogenous semitendinosus expansion suture repair (group C). The external fixation was used for immobilization after repair. After operation, the general situation of the animals was observed, and the infraspinatus tendon was harvested for gross observation at 6 weeks after operation. The biomechanical test of limit load and histological observation of tendon fibers were carried out. All the animals survived to the end of the experiment. All incisions healed well and no infection occurred. Gross observation showed more scar tissues at the end of infraspinatus muscle tendon than normal tendon in group A; no obvious tendon tissue was observed at the end of infraspinatus muscle tendon in group B; the infraspinatus muscle tendon was covered with some white scar tissue, but the tendon and the general direction could be observed in group C. The limit load of groups A, B, and C were (223.75 ± 24.28), (159.25 ± 34.87), and (233.25 ± 14.24) N respectively, group B was significantly lower than groups A and C (P < 0.05), and no significant differnce was found between group A and group C (P > 0.05). Histological observation showed normal arrangement of tendon fibers in group A; tendon fibers arranged disorderly in group B and tendon cells were significantly less than those of group A; tendon fibers arranged in neat in group C and tendon cells were more than those of group B. Canine autologous semitendinosus expansion repair of massive rotator cuff injury immobilization model can better simulate the clinical rotator cuff injury healing process, so it can be used as an ideal animal model for related research.

  3. Outcomes of acute Achilles tendon rupture repair with bone marrow aspirate concentrate augmentation.

    PubMed

    Stein, Benjamin E; Stroh, David Alex; Schon, Lew C

    2015-05-01

    Optimal treatment of acute Achilles tendon ruptures remains controversial. Positive results using stem-cell-bearing concentrates have been reported with other soft-tissue repairs, but no studies exist on outcomes of bone marrow aspirate concentrate (BMAC) augmentation in primary Achilles tendon repair. We reviewed patients with sport-related Achilles tendon ruptures treated via open repair augmented with BMAC injection from 2009 to 2011. Data on operative complications, strength, range of motion, rerupture, calf circumference and functional improvement through progressive return to sport and the Achilles tendon Total Rupture Score (ATRS) were analysed. A total of 27 patients (28 tendons) treated with open repair and BMAC injection were identified (mean age 38.3 ± 9.6 years). At mean follow-up of 29.7 ± 6.1 months, there were no reruptures. Walking without a boot was at 1.8 ± 0.7 months, participation in light activity was at 3.4 ± 1.8 months and 92% (25 of 27) of patients returned to their sport at 5.9 ± 1.8 months. Mean ATRS at final follow-up was 91 (range 72-100) points. One case of superficial wound dehiscence healed with local wound care. No soft-tissue masses, bone formation or tumors were observed in the operative extremity. Excellent results, including no re-ruptures and early mobilisation, were observed in this small cohort with open Achilles tendon repair augmented by BMAC. No adverse outcomes of biologic treatment were observed with this protocol. The efficacy of BMAC in the operative repair of acute Achilles tendon ruptures warrants further study. IV - Therapeutic.

  4. Patellar Tendon Repair Augmentation With a Knotless Suture Anchor Internal Brace: A Biomechanical Cadaveric Study.

    PubMed

    Rothfeld, Alex; Pawlak, Amanda; Liebler, Stephenie A H; Morris, Michael; Paci, James M

    2018-04-01

    Patellar tendon repair with braided polyethylene suture alone is subject to knot slippage and failure. Several techniques to augment the primary repair have been described. Purpose/Hypothesis: The purpose was to evaluate a novel patellar tendon repair technique augmented with a knotless suture anchor internal brace with suture tape (SAIB). The hypothesis was that this technique would be biomechanically superior to a nonaugmented repair and equivalent to a standard augmentation with an 18-gauge steel wire. Controlled laboratory study. Midsubstance patellar tendon tears were created in 32 human cadaveric knees. Two comparison groups were created. Group 1 compared #2 supersuture repair without augmentation to #2 supersuture repair with SAIB augmentation. Group 2 compared #2 supersuture repair with an 18-gauge stainless steel cerclage wire augmentation to #2 supersuture repair with SAIB augmentation. The specimens were potted and biomechanically loaded on a materials testing machine. Yield load, maximum load, mode of failure, plastic displacement, elastic displacement, and total displacement were calculated for each sample. Standard statistical analysis was performed. There was a statistically significant increase in the mean ± SD yield load and maximum load in the SAIB augmentation group compared with supersuture alone (mean yield load: 646 ± 202 N vs 229 ± 60 N; mean maximum load: 868 ± 162 N vs 365 ± 54 N; P < .001). Group 2 showed no statistically significant differences between the augmented repairs (mean yield load: 495 ± 213 N vs 566 ± 172 N; P = .476; mean maximum load: 737 ± 210 N vs 697 ± 130 N; P = .721). Patellar tendon repair augmented with SAIB is biomechanically superior to repair without augmentation and is equivalent to repair with augmentation with an 18-gauge stainless steel cerclage wire. This novel patellar tendon repair augmentation is equivalent to standard 18-gauge wire augmentation at time zero. It does not require a second surgery for removal, and it is biomechanically superior to primary repair alone.

  5. Prospective multicentre study of the clinical and functional outcomes following quadriceps tendon repair with suture anchors.

    PubMed

    Mille, F; Adam, A; Aubry, S; Leclerc, G; Ghislandi, X; Sergent, P; Garbuio, P

    2016-01-01

    Quadriceps tendon avulsions are typically treated by reattaching the tendon through bone tunnels, with or without tendon or hardware augmentation. The operated knee joint can be moved right away; however, tendon grafting or tension banding will be required to protect the repair, and the hardware must be removed later on. The goal of this study was to evaluate the clinical and functional outcomes when suture anchors are used to reattached torn quadriceps tendon, and also to assess tendon healing using MRI. Thirteen consecutive patients with avulsed quadriceps tendons were operated and then followed prospectively. The surgical technique consisted of tendon reattachment using at least three anchors, in addition to intratendinous weaving of the sutures. Weight bearing was allowed while using a splint. Rehabilitation was initiated immediately after surgery according to a set protocol. Eleven patients were followed for a mean of 14.7 months. Two retears occurred in patients who did not wear the splint. Eighty-two per cent of patients were satisfied or very satisfied with the outcome. The mean knee flexion was 124.5°. All patients were able to return to their pre-injury activity levels. The mean time for clinical and functional recovery was 3 months. MRI performed 6 months after the surgical repair revealed good tendon healing. This was the first prospective study performed on quadriceps avulsion patients undergoing suture anchor repair. Prior clinical case reports have shown that this method leads to predictable clinical and functional results. Our results were comparable to those in published cases. The procedure is simpler when only suture anchors are used. Tendon healing was observed on MRI in all cases. This simple, reproducible technique is free of the drawbacks associated with the typical repair augmentation.

  6. Quadriceps tendon autograft for arthroscopic knee ligament reconstruction: use it now, use it often.

    PubMed

    Sheean, Andrew J; Musahl, Volker; Slone, Harris S; Xerogeanes, John W; Milinkovic, Danko; Fink, Christian; Hoser, Christian

    2018-04-28

    Traditional bone-patellar tendon-bone and hamstring tendon ACL grafts are not without limitations. A growing body of anatomic, biomechanical and clinical data has demonstrated the utility of quadriceps tendon autograft in arthroscopic knee ligament reconstruction. The quadriceps tendon autograft provides a robust volume of tissue that can be reliably harvested, mitigating the likelihood of variably sized grafts and obviating the necessity of allograft augmentation. Modern, minimally invasive harvest techniques offer the advantages of low rates of donor site morbidity and residual extensor mechanism strength deficits. New data suggest that quadriceps tendon autograft may possess superior biomechanical characteristics when compared with bone-patella tendon-bone (BPTB) autograft. However, there have been very few direct, prospective comparisons between the clinical outcomes associated with quadriceps tendon autograft and other autograft options (eg, hamstring tendon and bone-patellar tendon-bone). Nevertheless, quadriceps tendon autograft should be one of the primary options in any knee surgeon's armamentarium. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Immunolocalization of Collagens (I and III) and Cartilage Oligomeric Matrix Protein in the Normal and Injured Equine Superficial Digital Flexor Tendon

    PubMed Central

    2013-01-01

    This is a descriptive study of tendon pathology with different structural appearances of repair tissue correlated to immunolocalization of cartilage oligomeric matrix protein (COMP) and type I and III collagens and expression of COMP mRNA. The material consists of nine tendons from seven horses (5–25 years old; mean age of 10 years) with clinical tendinopathy and three normal tendons from horses (3, 3, and 13 years old) euthanized for non-orthopedic reasons. The injured tendons displayed different repair-tissue appearances with organized and disorganized fibroblastic regions as well as areas of necrosis. The normal tendons presented distinct immunoreactivity for COMP and expression of COMP mRNA and type I collagen in the normal aligned fiber structures, but no immunolabeling of type III collagen. However, immunoreactivity for type III collagen was present in the endotenon surrounding the fiber bundles, where no expression of COMP could be seen. Immunostaining for type I and III collagens was present in all of the pathologic regions indicating repair tissue. Interestingly, the granulation tissues showed immunostaining for COMP and expression of COMP mRNA, indicating a role for COMP in repair and remodeling of the tendon after fiber degeneration and rupture. The present results suggest that not only type III collagen but also COMP is involved in the repair and remodeling processes of the tendon. PMID:23020676

  8. Maturational alterations in gap junction expression and associated collagen synthesis in response to tendon function.

    PubMed

    Young, N J; Becker, D L; Fleck, R A; Goodship, A E; Patterson-Kane, J C

    2009-07-01

    Energy-storing tendons including the equine superficial digital flexor tendon (SDFT) contribute to energetic efficiency of locomotion at high-speed gaits, but consequently operate close to their physiological strain limits. Significant evidence of exercise-induced microdamage has been found in the SDFT which appears not to exhibit functional adaptation; the degenerative changes have not been repaired by the tendon fibroblasts (tenocytes), and are proposed to accumulate and predispose the tendon to rupture during normal athletic activity. The anatomically opposing common digital extensor tendon (CDET) functions only to position the digit, experiencing significantly lower levels of strain and is rarely damaged by exercise. A number of studies have indicated that tenocytes in the adult SDFT are less active in collagen synthesis and turnover than those in the immature SDFT or the CDET. Gap junction intercellular communication (GJIC) is known to be necessary for strain-induced collagen synthesis by tenocytes. We postulate therefore that expression of GJ proteins connexin 43 and 32 (Cx43; Cx32), GJIC and associated collagen expression levels are high in the SDFT and CDET of immature horses, when the SDFT in particular grows significantly in cross-sectional area, but reduce significantly during maturation in the energy-storing tendon only. The hypothesis was tested using tissue from the SDFT and CDET of foetuses, foals, and young adult Thoroughbred horses. Cellularity and the total area of both Cx43 and Cx32 plaques/mm(2) of tissue reduced significantly with maturation in each tendon. However, the total Cx43 plaque area per tenocyte significantly increased in the adult CDET. Evidence of recent collagen synthesis in the form of levels of neutral salt-soluble collagen, and collagen type I mRNA was significantly less in the adult compared with the immature SDFT; procollagen type I amino-propeptide (PINP) and procollagen type III amino-propeptide (PIIINP) levels per mm(2) of tissue and PINP expression per tenocyte also decreased with maturation in the SDFT. In the CDET PINP and PIIINP expression per tenocyte increased in the adult, and exceeded those in the adult SDFT. The level of PINP per mm(2) was greater in the adult CDET than in the SDFT despite the higher cellularity of the latter tendon. In the adult SDFT, levels of PIIINP were greater than those of PINP, suggesting relatively greater synthesis of a weaker form of collagen previously associated with microdamage. Tenocytes in monolayers showed differences in Cx43 and Cx32 expression compared with those in tissue, however there were age- and tendon-specific phenotypic differences, with a longer time for 50% recovery of fluorescence after photobleaching in adult SDFT cells compared with those from the CDET and immature SDFT. As cellularity reduces following growth in the SDFT, a failure of the remaining tenocytes to show a compensatory increase in GJ expression and collagen synthesis may explain why cell populations are not able to respond to exercise and to repair microdamage in some adult athletes. Enhancing GJIC in mature energy-storing tendons could provide a strategy to increase the cellular synthetic and reparative capacity.

  9. Fixation Strength of Polyetheretherketone Sheath-and-Bullet Device for Soft Tissue Repair in the Foot and Ankle.

    PubMed

    Christensen, Jay; Fischer, Brian; Nute, Michael; Rizza, Robert

    Tendon transfers are often performed in the foot and ankle. Recently, interference screws have been a popular choice owing to their ease of use and fixation strength. Considering the benefits, one disadvantage of such devices is laceration of the soft tissues by the implant threads during placement that potentially weaken the structural integrity of the grafts. A shape memory polyetheretherketone bullet-in-sheath tenodesis device uses circumferential compression, eliminating potential damage from thread rotation and maintaining the soft tissue orientation of the graft. The aim of this study was to determine the pullout strength and failure mode for this device in both a synthetic bone analogue and porcine bone models. Thirteen mature bovine extensor tendons were secured into ten 4.0 × 4.0 × 4.0-cm cubes of 15-pound per cubic foot solid rigid polyurethane foam bone analogue models or 3 porcine femoral condyles using the 5 × 20-mm polyetheretherketone soft tissue anchor. The bullet-in-sheath device demonstrated a mean pullout of 280.84 N in the bone analog models and 419.47 N in the porcine bone models. (p = .001). The bullet-in-sheath design preserved the integrity of the tendon graft, and none of the implants dislodged from their original position. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Specialization of tendon mechanical properties results from interfascicular differences

    PubMed Central

    Thorpe, Chavaunne T.; Udeze, Chineye P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R. C.

    2012-01-01

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage. PMID:22764132

  11. Specialization of tendon mechanical properties results from interfascicular differences.

    PubMed

    Thorpe, Chavaunne T; Udeze, Chineye P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2012-11-07

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage.

  12. Biomaterials based strategies for rotator cuff repair.

    PubMed

    Zhao, Song; Su, Wei; Shah, Vishva; Hobson, Divia; Yildirimer, Lara; Yeung, Kelvin W K; Zhao, Jinzhong; Cui, Wenguo; Zhao, Xin

    2017-09-01

    Tearing of the rotator cuff commonly occurs as among one of the most frequently experienced tendon disorders. While treatment typically involves surgical repair, failure rates to achieve or sustain healing range from 20 to 90%. The insufficient capacity to recover damaged tendon to heal to the bone, especially at the enthesis, is primarily responsible for the failure rates reported. Various types of biomaterials with special structures have been developed to improve tendon-bone healing and tendon regeneration, and have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects. In this review, we first give a brief introduction of the anatomy of the rotator cuff and then discuss various design strategies to augment rotator cuff repair. Furthermore, we highlight current biomaterials used for repair and their clinical applications as well as the limitations in the literature. We conclude this article with challenges and future directions in designing more advanced biomaterials for augmentation of rotator cuff repair. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    PubMed

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  14. Comparison of a novel bone-tendon allograft with a human dermis-derived patch for repair of chronic large rotator cuff tears using a canine model.

    PubMed

    Smith, Matthew J; Cook, James L; Kuroki, Keiichi; Jayabalan, Prakash S; Cook, Cristi R; Pfeiffer, Ferris M; Waters, Nicole P

    2012-02-01

    This study tested a bone-tendon allograft versus human dermis patch for reconstructing chronic rotator cuff repair by use of a canine model. Mature research dogs (N = 15) were used. Radiopaque wire was placed in the infraspinatus tendon (IST) before its transection. Three weeks later, radiographs showed IST retraction. Each dog then underwent 1 IST treatment: debridement (D), direct repair of IST to bone with a suture bridge and human dermis patch augmentation (GJ), or bone-tendon allograft (BT) reconstruction. Outcome measures included lameness grading, radiographs, and ultrasonographic assessment. Dogs were killed 6 months after surgery and both shoulders assessed biomechanically and histologically. BT dogs were significantly (P = .01) less lame than the other groups. BT dogs had superior bone-tendon, tendon, and tendon-muscle integrity compared with D and GJ dogs. Biomechanical testing showed that the D group had significantly (P = .05) more elongation than the other groups whereas BT had stiffness and elongation characteristics that most closely matched normal controls. Radiographically, D and GJ dogs showed significantly more retraction than BT dogs (P = .003 and P = .045, respectively) Histologically, GJ dogs had lymphoplasmacytic infiltrates, tendon degeneration and hypocellularity, and poor tendon-bone integration. BT dogs showed complete incorporation of allograft bone into host bone, normal bone-tendon junctions, and well-integrated allograft tendon. The bone-tendon allograft technique re-establishes a functional IST bone-tendon-muscle unit and maintains integrity of repair in this model. Clinical trials using this bone-tendon allograft technique are warranted. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Mechanisms of tendon injury and repair

    PubMed Central

    Thomopoulos, Stavros; Parks, William C.; Rifkin, Daniel B.; Derwin, Kathleen A.

    2015-01-01

    Tendon disorders are common and lead to significant disability, pain, healthcare cost, and lost productivity. A wide range of injury mechanisms exist leading to tendinopathy or tendon rupture. Tears can occur in healthy tendons that are acutely overloaded (e.g., during a high speed or high impact event) or lacerated (e.g., a knife injury). Tendinitis or tendinosis can occur in tendons exposed to overuse conditions (e.g., an elite swimmer’s training regimen) or intrinsic tissue degeneration (e.g., age-related degeneration). The healing potential of a torn or pathologic tendon varies depending on anatomic location (e.g., Achilles vs. rotator cuff) and local environment (e.g., intrasynovial vs. extrasynovial). Although healing occurs to varying degrees, in general healing of repaired tendons follows the typical wound healing course, including an early inflammatory phase, followed by proliferative and remodeling phases. Numerous treatment approaches have been attempted to improve tendon healing, including growth factor- and cell-based therapies and rehabilitation protocols. This review will describe the current state of knowledge of injury and repair of the three most common tendinopathies-- flexor tendon lacerations, Achilles tendon rupture, and rotator cuff disorders-- with a particular focus on the use of animal models for understanding tendon healing. PMID:25641114

  16. Sonographic assisted diagnosis and treatment of bilateral gastrocnemius tendon rupture in a Labrador retriever repaired with fascia lata and polypropylene mesh.

    PubMed

    Swiderski, J; Fitch, R B; Staatz, A; Lowery, J

    2005-01-01

    This case report describes a four-year-old, eighty-five pound, male neutered Labrador retriever that was admitted with unilateral lameness and clinical findings consistent with a unilateral gostrocnemius tendon rupture. A prior history of trauma was not identified. Ultrasonagraphic evaluation revealed bilateral gastrocnemius tendon defects in which approximately 80% of the tendon was ruptured on the clinically normal side, yet mechanical function and anatomical length were not apparently altered. Bilateral surgical repair was performed utilizing primary tendon reconstruction, supported by fascia lata, autograft and polypropylene mesh. The repairs were protected with rigid costs for two weeks following surgery, and replaced with orthotics through the complete recovery period. Orthotics provided semi-rigid support and allowed removal for controlled intermittent physical therapy. This surgical repair technique, combined with orthotic support, allowed for early mobilization and good ultimate outcome for a complicated bilateral condition.

  17. Arthroscopically assisted percutaneous repair of fresh closed achilles tendon rupture by Kessler's suture.

    PubMed

    Tang, Kang-lai; Thermann, Hajo; Dai, Gang; Chen, Guang-xing; Guo, Lin; Yang, Liu

    2007-04-01

    Achilles tendon ruptures are difficult to repair, and the healing rate is low due to this structure's anatomic and physiological characteristics. It is essential to develop new techniques to increase the healing rate and decrease the rate of complications. To propose and evaluate a new percutaneous method of repairing fresh closed Achilles tendon ruptures by Kessler's suture under arthroscopy. Case series; Level of evidence, 4. Twenty patients were followed at least 12 months in this study. First, the torn ends of the Achilles tendon were debrided during arthroscopy. Then percutaneous repair of the Achilles tendon was performed using Kessler's suture by an inside-out technique. All cases were followed up for an average range of 21 months (range, 12-36 months). All patients were evaluated by clinical examination, magnetic resonance imaging, and the Lindholm scale. The torn ends were well aligned and sutured after the debridement under arthroscopy. According to the Lindholm scale, excellent results were seen in 15 cases and good in 5 cases. No patients had complications such as nerve injury, infection, or re-rupture at follow-up. Magnetic resonance imaging results showed that the ruptured Achilles tendons were repaired and remodeled very well in all patients. The present method is an effective surgical technique for repair of a closed rupture of the Achilles tendon. The short-term follow-up results were good, and recovery time was short. Few complications were found in our study cases.

  18. Tendon transfer to reconstruct wrist extension in children with obstetric brachial plexus palsy.

    PubMed

    Al-Qattan, M M

    2003-04-01

    This study reports on 20 children with obstetric brachial plexus palsy who underwent a tendon transfer to reconstruct wrist extension. The mean age at the time of tendon transfer was 8 years. There were seven patients with Erb's palsy and the remaining 13 had total palsy. The flexor carpi ulnaris was utilized 15 times and the flexor carpi radialis five times. The transferred tendon was sutured to the tendon of the extensor carpi radialis brevis. The result of the transfer was assessed according to a modified Medical Research Council (MRC) muscle grading system. A good result was obtained in 18 patients (modified MRC grade of 4) and a fair result (modified MRC grade of 3) in two. The choice of tendon transfer to reconstruct the wrist drop deformity in various conditions including adult traumatic brachial plexus injuries is discussed.

  19. Enhanced Soft Tissue Attachment and Fixation Using a Mechanically-Stimulated Cytoselective Tissue-Specific ECM Coating

    DTIC Science & Technology

    2012-08-01

    currently used for surgical reinforcement for tendon rotator cuff repair . All scaffolds in this study were seeded using this protocol. PLA fabric...extracellular matrix scaffolds for rotator cuff tendon repair . Biomechanical, biochemical, and cellular properties. J Bone Joint Surg Am 2006;88(12):2665-72...mechanical stimulation of a co-cultured biomaterial scaffold can improve/expedite healing of a tendon-to-bone interface for soft tissue repair . There

  20. The PASTA Bridge: A Technique for the Arthroscopic Repair of PASTA Lesions.

    PubMed

    Hirahara, Alan M; Andersen, Wyatt J

    2017-10-01

    PASTA (partial articular supraspinatus tendon avulsion) lesions of greater than 50% thickness are usually repaired, whereas those of less than 50% thickness receive subacromial decompression and debridement. However, tears of greater than 25% thickness of the tendon result in increased strain of the adjacent, intact tendon fibers. Re-creating the tendon footprint at the greater tuberosity is the goal of a repair. Transtendon repairs have been considered the gold standard in repair but have shown varying outcomes and are technically difficult procedures. This report details the PASTA bridge-a technique for the arthroscopic, percutaneous repair of PASTA lesions. The PASTA bridge uses a spinal needle to ensure the repair includes the leading edge of the good tissue and is at the appropriate angle and area. Most procedures use a knife or trocar blindly to access the joint to place anchors, which has the potential to damage surrounding tissues and result in poor anchor and suture placement. The PASTA bridge is a safe, reliable procedure that is easily reproducible and appropriate for surgeons of all experience levels and should be strongly considered when repairing PASTA lesions.

  1. Flexor tendon repair with a knotless, bidirectional barbed suture: an in vivo biomechanical analysis.

    PubMed

    Maddox, Grady E; Ludwig, Jonathan; Craig, Eric R; Woods, David; Joiner, Aaron; Chaudhari, Nilesh; Killingsworth, Cheryl; Siegal, Gene P; Eberhardt, Alan; Ponce, Brent

    2015-05-01

    To compare and analyze biomechanical properties and histological characteristics of flexor tendons either repaired by a 4-strand modified Kessler technique or using barbed suture with a knotless repair technique in an in vivo model. A total of 25 chickens underwent surgical transection of the flexor digitorum profundus tendon followed by either a 4-strand Kessler repair or a knotless repair with barbed suture. Chickens were randomly assigned to 1 of 3 groups with various postoperative times to death. Harvested tendons were subjected to biomechanical testing or histologic analysis. Harvested tendons revealed failures in 25% of knotless repairs (8 of 32) and 8% of 4-strand Kessler repairs (2 of 24). Biomechanical testing revealed no significant difference in tensile strength between 4-strand Kessler and barbed repairs; however, this lack of difference may be attributed to lower statistical power. We noted a trend toward a gradual decrease in strength over time for barbed repairs, whereas we noticed the opposite for the 4-strand Kessler repairs. Mode of failure during testing differed between repair types. The barbed repairs tended toward suture breakage as opposed to 4-strand Kessler repairs, which demonstrated suture pullout. Histological analysis identified no difference in the degree of inflammation or fibrosis; however, there was a vigorous foreign body reaction around the 4-strand Kessler repair and no such response around the barbed repairs. In this model, knotless barbed repairs trended toward higher in vivo failure rates and biomechanical inferiority under physiologic conditions, with each repair technique differing in mode of failure and respective histologic reaction. We are unable to recommend the use of knotless barbed repair over the 4-strand modified Kessler technique. For the repair techniques tested, surgeons should prefer standard Kessler repairs over the described knotless technique with barbed suture. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. Endoscopy-assisted percutaneous repair of acute Achilles tendon tears.

    PubMed

    Chiu, Chih-Hao; Yeh, Wen-Lin; Tsai, Min-Chien; Chang, Shih-Sheng; Hsu, Kuo-Yao; Chan, Yi-Sheng

    2013-08-01

    We developed a technique for endoscopy-assisted percutaneous repair of acute Achilles tendon tears. Nineteen patients with acute Achilles tendon tears were prospectively recruited into the study. All patients (18 male, 1 female) had sports-related injuries. Preoperative diagnosis was made from patient history, physical examination, and sonography. The average patient age was 38.7 years, and follow-up averaged 24 months. All patients received endoscopy-assisted percutaneous Achilles tendon repair with modified Bunnell sutures passed by bird beak and No. 5 Ethibond under direct visualization using 4.0-mm arthroscopy. Results were evaluated by physical examination, sonography, and magnetic resonance imaging (MRI). All 19 patients achieved tendon healing. All patients were evaluated by sonography, and the tendons of 16 patients were imaged using MRI to evaluate the extent of healing. Final dorsiflexion was 16 degrees and plantar flexion 26 degrees, and 95% of the patients (18/19) returned to their previous level of sporting activity. One patient developed a superficial infection, and 2 patients had postoperative sural nerve injury with numbness for 1 month. There were no other major complications. Endoscopy-assisted percutaneous repair of the Achilles tendon allowed good tendon healing and return to sports at 6 months. Sural nerve injury during surgery was a potential complication of this procedure. Level IV, retrospective case series.

  3. The Biomechanical and Histologic Effects of Platelet-Rich Plasma on Rat Rotator Cuff Repairs

    PubMed Central

    Beck, Jennifer; Evans, Douglas; Tonino, Pietro M.; Yong, Sherri; Callaci, John J.

    2013-01-01

    Background Rotator cuff tears are common injuries that are often treated with surgical repair. Because of the high concentration of growth factors within platelets, platelet-rich plasma (PRP) has the potential to enhance healing in rotator cuff repairs. Hypothesis Platelet-rich plasma would alter the biomechanical and histologic properties of rotator cuff repair during an acute injury response. Study Design Controlled laboratory study. Methods Platelet-rich plasma was produced from inbred donor rats. A tendon-from-bone supraspinatus tear was created surgically and an immediate transosseous repair performed. The control group underwent repair only. The PRP group underwent a repair with PRP augmentation. Rats in each group were sacrificed at 7, 14, and 21 days. The surgically repaired tendons underwent biomechanical testing, including failure load, stiffness, failure strain, and stress relaxation characteristics. Histological analysis evaluated the cellular characteristics of the repair tissue. Results At 7- and 21-day periods, augmentation with PRP showed statistically significant effects on the biomechanical properties of the repaired rat supraspinatus tear, but failure load was not increased at the 7-, 14-, or 21-day periods (P = .688, .209, and .477, respectively). The control group had significantly higher stiffness at 21 days (P = .006). The control group had higher failure strain at 7 days (P = .02), whereas the PRP group had higher failure strain at 21 days (P = .008). Histologically, the PRP group showed increased fibroblastic response and vascular proliferation at each time point. At 21 days, the collagen fibers in the PRP group were oriented in a more linear fashion toward the tendon footprint. Conclusion In this controlled, rat model study, PRP altered the tissue properties of the supraspinatus tendon without affecting the construct’s failure load. Clinical Relevance The decreased tendon tissue stiffness acutely and failure to enhance tendon-to-bone healing of repairs should be considered before augmenting rotator cuff repairs with PRP. Further studies will be necessary to determine the role of PRP in clinical practice. PMID:22822177

  4. Triple-Loaded Single-Row Versus Suture-Bridge Double-Row Rotator Cuff Tendon Repair With Platelet-Rich Plasma Fibrin Membrane: A Randomized Controlled Trial.

    PubMed

    Barber, F Alan

    2016-05-01

    To compare the structural healing and clinical outcomes of triple-loaded single-row with suture-bridging double-row repairs of full-thickness rotator cuff tendons when both repair constructs are augmented with platelet-rich plasma fibrin membrane. A prospective, randomized, consecutive series of patients diagnosed with full-thickness rotator cuff tears no greater than 3 cm in anteroposterior length were treated with a triple-loaded single-row (20) or suture-bridging double-row (20) repair augmented with platelet-rich plasma fibrin membrane. The primary outcome measure was cuff integrity by magnetic resonance imaging (MRI) at 12 months postoperatively. Secondary clinical outcome measures were American Shoulder and Elbow Surgeons, Rowe, Simple Shoulder Test, Constant, and Single Assessment Numeric Evaluation scores. The mean MRI interval was 12.6 months (range, 12-17 months). A total of 3 of 20 single-row repairs and 3 of 20 double-row repairs (15%) had tears at follow-up MRI. The single-row group had re-tears in 1 single tendon repair and 2 double tendon repairs. All 3 tears failed at the original attachment site (Cho type 1). In the double-row group, re-tears were found in 3 double tendon repairs. All 3 tears failed medial to the medial row near the musculotendinous junction (Cho type 2). All clinical outcome measures were significantly improved from the preoperative level (P < .0001), but there was no statistical difference between groups postoperatively. There is no MRI difference in rotator cuff tendon re-tear rate at 12 months postsurgery between a triple-loaded single-row repair or a suture-bridging double-row repair when both are augmented with platelet-rich plasma fibrin membrane. No difference could be demonstrated between these repairs on clinical outcome scores. I, Prospective randomized study. Copyright © 2016 Arthroscopy Association of North America. All rights reserved.

  5. Calcium-phosphate matrix with or without TGF-β3 improves tendon-bone healing after rotator cuff repair.

    PubMed

    Kovacevic, David; Fox, Alice J; Bedi, Asheesh; Ying, Liang; Deng, Xiang-Hua; Warren, Russell F; Rodeo, Scott A

    2011-04-01

    Rotator cuff tendon heals by formation of an interposed zone of fibrovascular scar tissue. Recent studies demonstrate that transforming growth factor-beta 3 (TGF-β(3)) is associated with tissue regeneration and "scarless" healing, in contrast to scar-mediated healing that occurs with TGF-β(1). Delivery of TGF-β(3) in an injectable calcium-phosphate matrix to the healing tendon-bone interface after rotator cuff repair will result in increased attachment strength secondary to improved bone formation and collagen organization and reduced scar formation of the healing enthesis. Controlled laboratory study. Ninety-six male Sprague-Dawley rats underwent unilateral detachment of the supraspinatus tendon followed by acute repair using transosseous suture fixation. Animals were allocated into 1 of 3 groups: (1) repair alone (controls, n = 32), (2) repair augmented by application of an osteoconductive calcium-phosphate (Ca-P) matrix only (n = 32), or (3) repair augmented with Ca-P matrix + TGF-β(3) (2.75 µg) at the tendon-bone interface (n = 32). Animals were euthanized at either 2 weeks or 4 weeks postoperatively. Biomechanical testing of the supraspinatus tendon-bone complex was performed at 2 and 4 weeks (n = 8 per group). Microcomputed tomography was utilized to quantitate bone microstructure at the repair site. The healing tendon-bone interface was evaluated with histomorphometry and immunohistochemical localization of collagen types I (COLI) and III (COLIII). Statistical analysis was performed using 2-way analysis of variance with significance set at P < .05. There was significantly greater load to failure of the Ca-P matrix + TGF-β(3) group compared with matrix alone or untreated controls at 4 weeks postoperatively (P = .04). At 2 weeks, microcomputed tomography revealed a larger volume of newly formed bone present at the healing enthesis in both experimental groups compared with the control group. By 4 weeks, this newly formed, woven bone had matured into calcified, lamellar bone. Histomorphometric analysis demonstrated significantly greater fibrocartilage and increased collagen organization at the healing tendon-bone insertion site in both experimental groups compared with the control group at 2 weeks (P = .04). Over time, TGF-β(3) delivery led to greater COLI expression compared with COLIII at the healing enthesis, indicating a more favorable COLI to COLIII ratio with administration of TGF-β(3). Augmentation with an osteoconductive Ca-P matrix at the tendon-bone repair site is associated with new bone formation, increased fibrocartilage, and improved collagen organization at the healing tendon-bone interface in the early postoperative period after rotator cuff repair. The addition of TGF-β(3) significantly improved strength of the repair at 4 weeks postoperatively and resulted in a more favorable COLI/COLIII ratio. The delivery of TGF-β(3) with an injectable Ca-P matrix at the supraspinatus tendon footprint has promise to improve healing after soft tissue repair.

  6. Open versus percutaneous repair in the treatment of acute Achilles tendon rupture: a randomized prospective study.

    PubMed

    Gigante, A; Moschini, A; Verdenelli, A; Del Torto, M; Ulisse, S; de Palma, L

    2008-02-01

    There is no agreement on the ideal type of surgical management for Achilles tendon rupture. The present randomized prospective study was performed to compare outcome data of open and percutaneous repair in the treatment of Achilles tendon rupture. Forty consecutive patients with acute rupture of Achilles tendon were recruited. Patients were randomized to receive open (group A) or percutaneous repair with Tenolig (group B). All patients followed the same rehabilitation protocol except for slight differences in the duration of immobilization. Follow-up included objective evaluation (at 4 and 12 months), subjective evaluation using the SF-12 questionnaire (at 24 months), and bilateral ultrasound scanning and isokinetic testing (at 12 months). The differences in the parameters evaluated clinically were not significant except for ankle circumference, which was significantly greater in group B. There were two minor complications in the open repair group and one case of failed repair in the percutaneous group. SF-12 questionnaire, ultrasound and isokinetic test data did not show significant differences between the groups. The present study demonstrates that the open and the percutaneous technique are both safe and effective in repairing the ruptured Achilles tendon and that both afford the same degree of restoration of clinical, ultrasound and isokinetic patterns. Medium-term results were substantially comparable. Percutaneous repair is performed on a day-surgery basis, it reduces cutaneous complications and operation times, and enables faster recovery, enhancing overall patient compliance. To us, these characteristics make it preferable to open repair in managing subcutaneous ruptures of Achilles tendon in non-professional sports practicing adults.

  7. A single dose of platelet-rich plasma improves the organization and strength of a surgically repaired rotator cuff tendon in rats.

    PubMed

    Dolkart, Oleg; Chechik, Ofir; Zarfati, Yaron; Brosh, Tamar; Alhajajra, Fadi; Maman, Eran

    2014-09-01

    Rotator cuff tear (RCT) is a common cause of pain and disability among adults. Platelet-rich plasma (PRP) is a fraction of whole blood containing concentrated growth factors and proteins important for tissue healing. This study aimed at investigating the effects of local autologous PRP injection on repaired rotator cuff (RC) tendon repair in rats. Following experimental RCT and suturing, 44 Wistar rats were randomly allocated into two groups: (1) RC repair only (controls); (2) RC repair + PRP administration-shoulders were treated with intra-articular PRP immediately after the repair. Animals were killed after 3 weeks and tendon, were tested biomechanically in tension (12 rats/group). The remaining tendons (10 rats/group) were stained using hematoxylin and eosin and Picro-sirius Red. Histological analysis evaluated the cellular aspects of the repair tissue. PRP administration following experimental RC tear and suture resulted in a significantly higher maximal load (p < 0.001) and stiffness (p < 0.005) as compared to non-treated animals. Bonar score of PRP-treated tendons was significantly better (p = 0.018) than the control group. Collagen birefringence was significantly higher in PRP shoulders (p = 0.002), indicating improved organization. Vascularity scores were similar in both groups. Application of a single dose autologous PRP in adjunct to surgical repair resultes in improved tendon-to-bone healing, assessed by histological and biomechanical testing in a rat model of acute RCT, when tested at 3 weeks compared to controls. Further studies will be essential to determine the role of PRP in clinical practice.

  8. 4-corner arthrodesis and proximal row carpectomy: a biomechanical comparison of wrist motion and tendon forces.

    PubMed

    Debottis, Daniel P; Werner, Frederick W; Sutton, Levi G; Harley, Brian J

    2013-05-01

    Controversy exists as to whether a proximal row carpectomy (PRC) is a better procedure than scaphoid excision with 4-corner arthrodesis for preserving motion in the painful posttraumatic arthritic wrist. The purpose of this study was to determine how the kinematics and tendon forces of the wrist are altered after PRC and 4-corner arthrodesis. We tested 6 fresh cadaver forearms for the extremes of wrist motion and then used a wrist simulator to move them through 4 cyclic dynamic wrist motions, during which time we continuously recorded the tendon forces. We repeated the extremes of wrist motion measurements and the dynamic motions after scaphoid excision with 4-corner arthrodesis, and then again after PRC. We analyzed extremes of wrist motion and the peak tendon forces required for each dynamic motion using a repeated measures analysis of variance. Wrist extremes of motion significantly decreased after both the PRC and 4-corner arthrodesis compared with the intact wrist. Wrist flexion decreased on average 13° after 4-corner arthrodesis and 12° after PRC. Extension decreased 20° after 4-corner arthrodesis and 12° after PRC. Four-corner arthrodesis significantly decreased wrist ulnar deviation from the intact wrist. Four-corner arthrodesis allowed more radial deviation but less ulnar deviation than the PRC. The average peak tendon force was significantly greater after 4-corner arthrodesis than after PRC for the extensor carpi ulnaris during wrist flexion-extension, circumduction, and dart throw motions. The peak forces were significantly greater after 4-corner arthrodesis than in the intact wrist for the extensor carpi ulnaris during the dart throw motion and for the flexor carpi ulnaris during the circumduction motion. The peak extensor carpi radialis brevis force after PRC was significantly less than in the intact wrist. The measured wrist extremes of motion decreased after both 4-corner arthrodesis and PRC. Larger peak tendon forces were required to achieve identical wrist motions with the 4-corner arthrodesis compared with the intact wrist. We observed smaller forces for the PRC. These results may help explain why PRC shows early clinical improvement, yet may lead to degenerative arthritis. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Single-row versus double-row repair of the distal Achilles tendon: a biomechanical comparison.

    PubMed

    Pilson, Holly; Brown, Philip; Stitzel, Joel; Scott, Aaron

    2012-01-01

    Surgery for recalcitrant insertional Achilles tendinopathy often consists of partial or total release of the insertion site, debridement of the diseased portion of the tendon, calcaneal ostectomy, and reattachment of the Achilles to the calcaneus. Although single-row and double-row techniques exist for repair of the detached Achilles tendon, biomechanical data are lacking to support one technique over the other. Based on data extrapolated from the study of rotator cuff repairs, we hypothesized that a double-row construct would provide superior fixation strength over a single-row repair. Eighteen human cadaveric Achilles tendons (9 matched pairs) with attached calcanei were repaired with single-row or double-row techniques. Specimens were mounted in a servohydraulic materials testing machine, subjected to a preconditioning cycle, and loaded to failure. Failure was defined as suture breakage or pullout, midsubstance tendon rupture, or anchor pullout. Among the failures were 12 suture failures, 5 proximal-row anchor failures, and 1 distal-row anchor failure. No midsubstance tendon ruptures or testing apparatus failures were observed. There were no statistically significant differences in the peak load to failure between the single-row and double-row repairs (p = .46). Similarly, no significant differences were observed with regards to mean energy expenditure to failure (p = .069). The present study demonstrated no biomechanical advantages of the double-row repair over a single-row repair. Despite the lack of a clear biomechanical advantage, there may exist clinical advantages of a double-row repair, such as reduction in knot prominence and restoration of the Achilles footprint. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Recent evolutions in flexor tendon repairs and rehabilitation.

    PubMed

    Tang, Jin Bo

    2018-06-01

    This article reviews some recent advancements in repair and rehabilitation of the flexor tendons. These include placing sparse or no peripheral suture when the core suture is strong and sufficiently tensioned, allowing the repair site to be slightly bulky, aggressively releasing the pulleys (including the entire A2 pulley or both the A3 and A4 pulleys when necessary), placing a shorter splint with less restricted wrist positioning, and allowing out-of-splint active motion. The reported outcomes have been favourable with few or no repair ruptures and no function-disturbing tendon bowstringing. These changes favour easier surgeries. The recent reports have cause to re-evaluate long-held guidelines of a non-bulky repair site and the necessity of a standard peripheral suture. Emerging understanding posits that minor clinically noticeable tendon bowstringing does not affect hand function, and that free wrist positioning and out-of-splint motion are safe when strong surgical repairs are used and the pulleys are properly released.

  11. An electrospun polydioxanone patch for the localisation of biological therapies during tendon repair.

    PubMed

    Hakimi, O; Murphy, R; Stachewicz, U; Hislop, S; Carr, A J

    2012-10-23

    Rotator cuff tendon pathology is thought to account for 30-70 % of all shoulder pain. For cases that have failed conservative treatment, surgical re-attachment of the tendon to the bone with a non-absorbable suture is a common option. However, the failure rate of these repairs is high, estimated at up to 75 %. Studies have shown that in late disease stages the tendon itself is extremely degenerate, with reduced cell numbers and poor matrix organisation. Thus, it has been suggested that adding biological factors such as platelet rich plasma (PRP) and mesenchymal stem cells could improve healing. However, the articular capsule of the glenohumeral joint and the subacromial bursa are large spaces, and injecting beneficial factors into these sites does not ensure localisation to the area of tendon damage. Thus, the aim of this study was to develop a biocompatible patch for improving the healing rates of rotator cuff repairs. The patch will create a confinement around the repair area and will be used to guide injections to the vicinity of the surgical repair. Here, we characterised and tested a preliminary prototype of the patch utilising in vitro tools and primary tendon-derived cells, showing exceptional biocompatibility despite rapid degradation, improved cell attachment and that cells could migrate across the patch towards a chemo-attractant. Finally, we showed the feasibility of detecting the patch using ultrasound and injecting liquid into the confinement ex vivo. There is a potential for using this scaffold in the surgical repair of interfaces such as the tendon insertion in the rotator cuff, in conjunction with beneficial factors.

  12. [Application of silk-based tissue engineering scaffold for tendon / ligament regeneration].

    PubMed

    Hu, Yejun; Le, Huihui; Jin, Zhangchu; Chen, Xiao; Yin, Zi; Shen, Weiliang; Ouyang, Hongwei

    2016-03-01

    Tendon/ligament injury is one of the most common impairments in sports medicine. The traditional treatments of damaged tissue repair are unsatisfactory, especially for athletes, due to lack of donor and immune rejection. The strategy of tissue engineering may break through these limitations, and bring new hopes to tendon/ligament repair, even regeneration. Silk is a kind of natural biomaterials, which has good biocompatibility, wide range of mechanical properties and tunable physical structures; so it could be applied as tendon/ligament tissue engineering scaffolds. The silk-based scaffold has robust mechanical properties; combined with other biological ingredients, it could increase the surface area, promote more cell adhesion and improve the biocompatibility. The potential clinical application of silk-based scaffold has been confirmed by in vivo studies on tendon/ligament repairing, such as anterior cruciate ligament, medial collateral ligament, achilles tendon and rotator cuff. To develop novel biomechanically stable and host integrated tissue engineered tendon/ligament needs more further micro and macro studies, combined with product development and clinical application, which will give new hope to patients with tendon/ligament injury.

  13. Repair of Double Head Pectoralis Major Tendon Avulsion into its Native Footprint Using Bi-cortical EndoButtons and Tendon Sliding Technique.

    PubMed

    Prabhu, Jagadish; Faqi, Mohammed Khalid; Alkhalifa, Fahad; Tayara, Bader Kamal; Awad, Rashad Khamis

    2017-01-01

    Injuries to the pectoralis major muscle are relatively infrequent. The mechanism of injury is usually an eccentric shortening of the pectoralis major under heavy load, such as when performing a bench press exercise. We report a case that presented to us with a history of sudden pain in the left pectoral region while doing heavy bench press exercise. The patient sustained a type III D pectoralis muscle -tendon avulsion. Surgical repair was done through a bi-cortical tendon sliding technique using two cortical buttons. In this article we describe our modifications to the previously described surgical technique for the pectoralis major tendon repair using the EndoButton and tension - slide technique, aiming to overcome the possible complications.

  14. Effect of exercise on age-related changes in collagen fibril diameter distributions in the common digital extensor tendons of young horses.

    PubMed

    Edwards, Lindsey J; Goodship, Allen E; Birch, Helen L; Patterson-Kane, Janet C

    2005-04-01

    To determine whether specific treadmill exercise regimens would accelerate age-related changes in collagen fibril diameter distributions in the common digital extensor tendon (CDET) of the forelimbs of young Thoroughbreds. 24 female Thoroughbreds. Horses were trained for 18 weeks (6 horses; short term) or 18 months (5 horses; long term) on a high-speed treadmill; 2 age-matched control groups (6 horses/group) performed walking exercise only. Horses were (mean +/- SD) 24 +/- 1 months and 39 +/- 1 months old at termination of the short-term and long-term regimens, respectively. Midmetacarpal CDET specimens were obtained and processed for transmission electron microscopy. Diameter and area of at least 1,000 collagen fibrils/specimen were measured by use of computerized image analysis. Mass-average diameter (MAD) of collagen fibrils and collagen fibril index were calculated for each horse. Collagen fibril MAD for the older horses was significantly less than that for the younger horses. Exercise did not significantly affect fibril diameter or distributions in either age group, and collagen fibril index did not differ significantly between groups. Age-related reduction in collagen fibril MAD agreed with findings for other tendons and species. Training did not accelerate age-related change in the CDET in contrast to a reported decrease in collagen fibril MAD in the superficial digital flexor tendon of horses trained long term. Our results support the concept that the functionally distinct nature of the CDET and superficial digital flexor tendon in horses results in fundamentally different responses to high-speed exercise regimens.

  15. Biomechanical effects of a 2 suture-pass medial inter-implant mattress on transosseous-equivalent rotator cuff repair and considerations for a "technical efficiency ratio".

    PubMed

    Park, Maxwell C; Peterson, Alexander; Patton, John; McGarry, Michelle H; Park, Chong J; Lee, Thay Q

    2014-03-01

    Rotator cuff repair involving fewer tendon suture passes without compromising biomechanical performance would represent a technical advancement. An inter-implant "medial pulley-mattress" transosseous-equivalent (MP-TOE) repair requiring fewer tendon suture-passes was hypothesized to provide equivalent biomechanical characteristics compared to the control. In 6 human cadaveric shoulders, a transosseous-equivalent (TOE) repair (control) was performed utilizing 2 separate medial mattresses resulting in 4 tendon-bridging sutures. In 6 matched-pairs, 2 single-loaded anchors were used to create a medial inter-implant mattress construct (all sutures shuttled in 1 tendon pass per anchor)-after knot-tying, the same tendon-bridging pattern as the control was created. A materials testing machine cyclically loaded each repair from 10-180 N for 30 cycles; each repair subsequently underwent failure testing. Gap and strain were measured with a video digitizing system. A "technical efficiency ratio" (TER) was defined as: (#knots + #suture passes + #suture limbs)/#fixation points. Cyclic and failure testing demonstrated no significant differences between constructs. Gap formation at cycle 30 was 5.3 ± 0.8 mm (TOE) and 5.0 ± 0.3 mm (MP-TOE) (P = .62). Cycle 30 anterior strain values were -16.0 ± 7.3% (TOE) and -15.8 ± 6.6% (MP-TOE) (P = .99). Yield loads were 208.7 ± 2.7 N (TOE) and 204.0 ± 1.3 N (MP-TOE) (P = .17). Mode of failure demonstrated less tendon cut-out with the MP-TOE repair. The MP-TOE repair has a TER of 2.0 vs 2.5 for the control. The MP-TOE repair requiring fewer tendon suture passes, yet creating an additional inter-implant mattress configuration, is biomechanically equivalent to the original TOE technique, and may limit failure with improved medial load-sharing capacity. A TER may help quantify technical ease and help standardize comparisons between repair techniques. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  16. Comparison of Clinical and Structural Outcomes by Subscapularis Tendon Status in Massive Rotator Cuff Tear.

    PubMed

    Lee, Sung Hyun; Nam, Dae Jin; Kim, Se Jin; Kim, Jeong Woo

    2017-09-01

    The subscapularis tendon is essential in maintaining normal glenohumeral biomechanics. However, few studies have addressed the outcomes of tears extending to the subscapularis tendon in massive rotator cuff tears. To assess the clinical and structural outcomes of arthroscopic repair of massive rotator cuff tears involving the subscapularis. Cohort study; Level of evidence, 3. Between January 2010 and January 2014, 122 consecutive patients with massive rotator cuff tear underwent arthroscopic rotator cuff repair. Overall, 122 patients were enrolled (mean age, 66 years; mean follow-up period, 39.5 months). Patients were categorized into 3 groups based on subscapularis tendon status: intact subscapularis tendon (I group; n = 45), tear involving less than the superior one-third (P group; n = 35), and tear involving more than one-third of the subscapularis tendon (C group; n = 42). All rotator cuff tears were repaired; however, subscapularis tendon tears involving less than the superior one-third in P group were only debrided. Pain visual analog scale, Constant, and American Shoulder and Elbow Surgeons scores and passive range of motion were measured preoperatively and at the final follow-up. Rotator cuff integrity, global fatty degeneration index, and occupation ratio were determined via magnetic resonance imaging preoperatively and 6 months postoperatively. We identified 37 retears (31.1%) based on postoperative magnetic resonance imaging evaluation. Retear rate in patients in the C group (47.6%) was higher than that in the I group (22.9%) or P group (20.0%) ( P = .011). Retear subclassification based on the involved tendons showed that subsequent subscapularis tendon retears were noted in only the C group. The improvement in clinical scores after repair was statistically significant in all groups but not different among the groups. Between-group comparison showed significant differences in preoperative external rotation ( P = .021). However, no statistically significant difference was found in any shoulder range of motion measurements after surgery. Arthroscopic repair of massive tears results in substantial improvements in shoulder function, despite the presence of combined subscapularis tears. However, this study showed a high failure rate of massive posterosuperior rotator cuff tear repair extending more than one-third of the subscapularis tendon. When combined subscapularis tendon tear was less than the superior one-third of the subscapularis tendon, arthroscopic debridement was a reasonable treatment method where comparable clinical and anatomic outcomes could be expected.

  17. IFSSH Flexor Tendon Committee report 2014: from the IFSSH Flexor Tendon Committee (Chairman: Jin Bo Tang).

    PubMed

    Tang, Jin Bo; Chang, James; Elliot, David; Lalonde, Donald H; Sandow, Michael; Vögelin, Esther

    2014-01-01

    Hand surgeons continue to search for the best surgical flexor tendon repair and treatment of the tendon sheaths and pulleys, and they are attempting to establish postoperative regimens that fit diverse clinical needs. It is the purpose of this report to present the current views, methods, and suggestions of six senior hand surgeons from six different countries - all experienced in tendon repair and reconstruction. Although certainly there is common ground, the report presents provocative views and approaches. The report reflects an update in the views of the committee. We hope that it is helpful to surgeons and therapists in treating flexor tendon injuries.

  18. Medial versus lateral supraspinatus tendon properties: implications for double-row rotator cuff repair.

    PubMed

    Wang, Vincent M; Wang, Fan Chia; McNickle, Allison G; Friel, Nicole A; Yanke, Adam B; Chubinskaya, Susan; Romeo, Anthony A; Verma, Nikhil N; Cole, Brian J

    2010-12-01

    Rotator cuff repair retear rates range from 25% to 90%, necessitating methods to improve repair strength. Although numerous laboratory studies have compared single-row with double-row fixation properties, little is known regarding regional (ie, medial vs lateral) suture retention properties in intact and torn tendons. A torn supraspinatus tendon will have reduced suture retention properties on the lateral aspect of the tendon compared with the more medial musculotendinous junction. Controlled laboratory study. Human supraspinatus tendons (torn and intact) were randomly assigned for suture retention mechanical testing, ultrastructural collagen fibril analysis, or histologic testing after suture pullout testing. For biomechanical evaluation, sutures were placed either at the musculotendinous junction (medial) or 10 mm from the free margin (lateral), and tendons were elongated to failure. Collagen fibril assessments were performed using transmission electron microscopy. Intact tendons showed no regional differences with respect to suture retention properties. In contrast, among torn tendons, the medial region exhibited significantly higher stiffness and work values relative to the lateral region. For the lateral region, work to 10-mm displacement (1592 ± 261 N-mm) and maximum load (265 ± 44 N) for intact tendons were significantly higher (P < .05) than that of torn tendons (1086 ± 388 N-mm and 177 ± 71 N, respectively). For medial suture placement, maximum load, stiffness, and work of intact and torn tendons were similar (P > .05). Regression analyses for the intact and torn groups revealed generally low correlations between donor age and the 3 biomechanical indices. For both intact and torn tendons, the mean fibril diameter and area density were greater in the medial region relative to the lateral (P ≤ .05). In the lateral tendon, but not the medial region, torn specimens showed a significantly lower fibril area fraction (48.3% ± 3.8%) than intact specimens (56.7% ± 3.6%, P < .05). Superior pullout resistance of medially placed sutures may provide a strain shielding effect for the lateral row after double-row repair. Larger diameter collagen fibrils as well as greater fibril area fraction in the medial supraspinatus tendon may provide greater resistance to suture migration. While clinical factors such as musculotendinous integrity warrant strong consideration for surgical decision making, the present ultrastructural and biomechanical results appear to provide a scientific rationale for double-row rotator cuff repair where sutures are placed more medially at the muscle-tendon junction.

  19. Omega "Ω" Pulley Plasty for Surgical Management of DeQuervain's Disease.

    PubMed

    Bakhach, Joseph; Chaya, Bachar; Papazian, Nazareth

    2018-06-01

    DeQuervain tenosynovitis, refractory to medical conservative treatment, has been traditionally treated by a simple division of the pulley, a procedure associated with several complications. Many authors attempted to prevent these complications by describing techniques of pulley reconstruction after its release necessitating suturing the different flaps and subsequently promoting extensor tendons adhesions. The authors present an alternative procedure for the first extensor compartment pulley decompression: "Omegaplasty". 25 Patients with 29 DeQuervain tenosynovitis cases were enrolled in a prospective, nonrandomized clinical trial from 2012 to 2016. At enrollment they were offered the option of Omegaplasty as a surgical treatment modality for their cases. The procedure is based on liberating the anterior attachment of the pulley from the anterior lip of the styloïd process while respecting its continuity with the periosteal flap as well as promoting expansion of the tunnel volume. All operated patients were evaluated using the "Opposition Kapandji Score". The authors present the results of 29 different "Omegaplasty" procedures. Based on the Kapandji opposition score, twenty cases scored 10/10 while the remaining nine cases yielded an 8/10 score each. The described technique is simple, reliable and respects the extensor tendons gliding physiology and biodynamics. By preserving the anatomical continuity of the first extensor compartment pulley at the wrist, the risk of adhesion formation is reduced. The preliminary results are encouraging and provide the "Ω" plasty the potential to be considered as a surgical option for treatment of De Quervain Tenosynovitis.

  20. Clinical Results of Flexor Tendon Repair in Zone II Using a six Strand Double Loop Technique.

    PubMed

    Savvidou, Christiana; Tsai, Tsu-Min

    2015-06-01

    The purpose of this study is to report the clinical results after repair of flexor tendon zone II injuries utilizing a 6-strand double-loop technique and early post-operative active rehabilitation. We retrospectively reviewed 22 patients involving 51 cases with zone II flexor tendon repair using a six strand double loop technique from September 1996 to December 2012. Most common mechanism of injuries was sharp lacerations (86.5 %). Tendon injuries occurred equally in manual and non-manual workers and were work-related in 33 % of the cases. The Strickland score for active range of motion (ROM) postoperatively was excellent and good in the majority of the cases (81 %). The rupture rate was 1.9 %. The six strand double loop technique for Zone II flexor tendon repair leads to good and excellent motion in the majority of patients and low re- rupture rate. It is clinically effective and allows for early postoperative active rehabilitation.

  1. Primary repair of retracted distal biceps tendon ruptures in extreme flexion.

    PubMed

    Morrey, Mark E; Abdel, Matthew P; Sanchez-Sotelo, Joaquin; Morrey, Bernard F

    2014-05-01

    Distal biceps tendon ruptures may have tendinous retraction, making primary repair difficult and calling into question the need for graft reconstruction. The decision for when to primarily fix or augment high-flexion repairs has not been addressed. We hypothesized high-flexion repairs would have good outcomes without graft augmentation. The purpose of this study was to examine allograft use and outcomes of distal biceps tendon ruptures requiring repair in greater than 60° of flexion. This was a retrospective case-control study 188 distal biceps tendon repairs; of these, 19 chronic and 4 acute cases were identified with repairs of >60° of flexion using a 2-incision technique. Graft need, complications, and Mayo Elbow Performance Score to assess function, were examined with a record review. Patients were surveyed regarding return to work and subjective satisfaction. A control group matched for surgeon, chronicity, and age, but without a high-flexion repair, was compared with cases by using the Student paired t test. Graft augmentation was used in 1 patient with poor tendon quality. The Mayo Elbow Performance Score was 100 for all 23 patients, with extension/flexion range of motion from 3° to 138°. All were subjectively "very satisfied/satisfied," with full work return, yet 3 reported mild fatigability. There were 4 complications: 3 transient lateral antebrachial cutaneous neurapraxias and 1 rerupture at the myotendinous junction after retrauma. Differences between cases and controls were not statistically significant. Contracted distal biceps tendons may be reliably reattached to their anatomic insertion with up to 90° of elbow flexion. This lessens the need for reconstruction in such circumstances. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  2. The Effects of Platelet-Rich Plasma on Bone Marrow Stromal Cell Transplants for Tendon Healing In Vitro

    PubMed Central

    Morizaki, Yutaka; Zhao, Chunfeng; An, Kai-Nan; Amadio, Peter C.

    2010-01-01

    Purpose In this study we investigated the effect of platelet-rich plasma (PRP) and bone-marrow derived stromal cell (BMSC)-seeded interposition in an in vitro canine tendon repair model. Methods Bone marrow, peripheral blood, and tendons were harvested from mixed breed dogs. BMSC were cultured and passaged from adherent cells of bone marrow suspension. PRP was purified from peripheral blood using a commercial kit. 192 flexor digitorum profundus tendons were used for the study. Tendons repaired with a simple suture were used as a control group. In treatment groups, a collagen gel patch was interposed at the tendon repair site prior to suture. There were three treatment groups according to the type of collagen patch; a patch with PRP, a patch with BMSC, and a patch with PRP and BMSC. The repaired tendons were evaluated by biomechanical testing and by histological survey after 2 and 4 weeks in tissue culture. To evaluate viability, cells were labeled with PKH26 and surveyed under confocal microscopy after culture. Results The maximum breaking strength and stiffness of the healing tendons with the BMSC-seeded PRP patch was significantly higher than the healing tendons without a patch or with a cell-seeded patch (p<0.02). Viable BMSC were present at both 2 and 4 weeks. Conclusions PRP enhanced the effect of BMSC-seeded collagen gel interposition in this in vitro model. Based on these results we now plan to investigate this effect in vivo. PMID:20951509

  3. Cell phenotypic variation in normal and damaged tendons

    PubMed Central

    Clegg, Peter D; Strassburg, Sandra; Smith, Roger K

    2007-01-01

    Injuries to tendons are common in both human athletes as well as in animals, such as the horse, which are used for competitive purposes. Furthermore, such injuries are also increasing in prevalence in the ageing, sedentary population. Tendon diseases often respond poorly to treatment and require lengthy periods of rehabilitation. The tendon has a unique extracellular matrix, which has developed to withstand the mechanical demands of such tensile-load bearing structures. Following injury, any repair process is inadequate and results in tissue that is distinct from original tendon tissue. There is growing evidence for the key role of the tendon cell (tenocyte) in both the normal physiological homeostasis and regulation of the tendon matrix and the pathological derangements that occur in disease. In particular, the tenocyte is considered to have a major role in effecting the subclinical matrix degeneration that is thought to occur prior to clinical disease, as well as in the severe degradative events that occur in the tendon at the onset of clinical disease. Furthermore, the tenocyte is likely to have a central role in the production of the biologically inadequate fibrocartilaginous repair tissue that develops subsequent to tendinopathy. Understanding the biology of the tenocyte is central to the development of appropriate interventions and drug therapies that will either prevent the onset of disease, or lead to more rapid and appropriate repair of injured tendon. Central to this is a full understanding of the proteolytic response in the tendon in disease by such enzymes as metalloproteinases, as well as the control of the inappropriate fibrocartilaginous differentiation. Finally, it is important that we understand the role of both intrinsic and extrinsic cellular elements in the repair process in the tendon subsequent to injury. PMID:17696903

  4. Does strand configuration and number of purchase points affect the biomechanical behavior of a tendon repair? A biomechanical evaluation using different kessler methods of flexor tendon repair.

    PubMed

    Dogramaci, Yunus; Kalaci, Aydiner; Sevinç, Teoman Toni; Esen, Erdinc; Komurcu, Mahmut; Yanat, Ahmet Nedim

    2008-09-01

    This study compares the mechanical properties of modified Kessler and double-modified Kessler flexor tendon repair techniques and evaluates simple modifications on both methods. Forty fresh sheep flexor tendons were divided equally into four groups. A transverse sharp cut was done in the middle of each tendon and then repaired with modified Kessler technique, modified Kessler with additional purchase point in the midpoint of each longitudinal strand, double-modified Kessler technique, or a combination of outer Kessler and inner cruciate configuration based on double-modified Kessler technique. The tendons were tested in a tensile testing machine to assess the mechanical performance of the repairs. Outcome measures included gap formation and ultimate forces. The gap strengths of the double-modified Kessler technique (30.85 N, SD 1.90) and double-modified Kessler technique with inner cruciate configuration (33.60 N, SD 4.64) were statistically significantly greater than that of the two-strand modified Kessler (22.56 N, SD 3.44) and modified Kessler with additional purchase configuration (21.75 N, SD 4.03; Tukey honestly significant difference test, P < 0.000). There were statistically significant differences in failure strengths of the all groups (analysis of variance, P < 0.000). With an identical number of strands, the gap formation and ultimate forces of the repairs were not changed by additional locking purchase point in modified Kessler repair or changing the inner strand configuration in double-modified Kessler repair. The results of this study show that the number of strands across the repair site together with the number of locking loops clearly affects the strength of the repair; meanwhile, the longitudinal strand orientation and number of purchase points in a single loop did not affect its strength.

  5. Does Additional Biceps Augmentation Improve Rotator Cuff Healing and Clinical Outcomes in Anterior L-Shaped Rotator Cuff Tears? Clinical Comparisons With Arthroscopic Partial Repair.

    PubMed

    Jeon, Yoon Sang; Lee, Juyeob; Kim, Rag Gyu; Ko, Young-Won; Shin, Sang-Jin

    2017-11-01

    The repair of anterior L-shaped tears is usually difficult because of the lack of anterior rotator cuff tendon to cover the footprint. The biceps tendon is usually exposed from the retracted anterolateral corner of the torn tendon and can be easily used to augment rotator cuff repair. Hypothesis/Purpose: This study compared the clinical outcomes of the biceps augmentation technique with those of partial tendon repair for the arthroscopic treatment of large anterior L-shaped rotator cuff tears to evaluate the role of additional biceps augmentation in tendon healing. We hypothesized that the biceps augmentation technique would lead to a lower rotator cuff tendon retear rate and provide satisfactory functional outcomes. Cohort study; Level of evidence, 3. This study included 64 patients with anterior L-shaped rotator cuff tears who underwent arthroscopic repair. Patients were divided into 2 groups: group A (31 patients) underwent repair of an anterior L-shaped tear combined with biceps augmentation, and group B (33 patients) had a partially repaired tendon whose footprint was exposed after repair without undue tension on the retracted tendon. Clinical evaluations were performed using the American Shoulder and Elbow Surgeons (ASES) score, Constant score, muscle strength, visual analog scale for pain, and patient satisfaction. Magnetic resonance imaging (MRI) was performed for tendon integrity at 6 months postoperatively. The mean period of follow-up was 29.1 ± 3.5 months (range, 24-40 months). The mean ASES and Constant scores significantly improved from 52.8 ± 10.6 and 43.2 ± 9.9 preoperatively to 88.2 ± 6.9 and 86.8 ± 6.2 at final follow-up in group A ( P < .001) and from 53.0 ± 11.8 and 44.3 ± 11.3 preoperatively to 87.4 ± 7.2 and 87.9 ± 7.3 at final follow-up in group B ( P < .001). Overall muscle strength (given as % of the other side's strength) significantly increased from preoperatively to final follow-up in group A (forward flexion [FF]: 62.0 ± 8.2 to 89.0 ± 8.6; external rotation [ER]: 57.5 ± 9.9 to 86.8 ± 9.3; internal rotation [IR]: 68.1 ± 10.8 to 88.1 ± 8.4; P < .001) and group B (FF: 59.9 ± 9.6 to 87.7 ± 9.0; ER: 58.6 ± 9.3 to 86.2 ± 7.5; IR: 70.0 ± 9.3 to 87.0 ± 8.4; P < .001). Twenty-one patients (67.7%) in group A and 20 patients (60.6%) in group B showed a healed rotator cuff tendon on postoperative MRI. The retear rate between the 2 groups showed no significant difference ( P = .552). Regarding clinical outcomes, both groups had no significant difference in the ASES score ( P = .901), Constant score ( P = .742), and muscle strength. There was no significant difference in the clinical outcomes and retear rate of anterior L-shaped tears between biceps augmentation and partial tendon repair. Additional biceps augmentation proved to have no enhancement in tendon healing. A precise method such as only partial tendon repair for reducing the footprint exposure without undue tension may be considered as one of the treatment options for large anterior L-shaped rotator cuff tears.

  6. A dynamic traction splint for the management of extrinsic tendon tightness.

    PubMed

    Dovelle, S; Heeter, P K; Phillips, P D

    1987-02-01

    The dynamic traction splint designed by therapists at Walter Reed Army Medical Center is used for the management of extrinsic extensor tendon tightness commonly seen in brachial plexus injuries and traumatic soft tissue injuries of the upper extremity. The two components of the splint allow for simultaneous maximum flexion of the MCP and IP joints. This simple and economical splint provides an additional modality to any occupational therapy service involved in the management of upper extremity disorders.

  7. Subscapularis tendon tears

    PubMed Central

    Lenart, Brett A.; Ticker, Jonathan B.

    2017-01-01

    Tears of the subscapularis tendon have been under-recognised until recently. Therefore, a high index of suspicion is essential for diagnosis. A directed physical examination, including the lift-off, belly-press and increased passive external rotation can help identify tears of the subscapularis. All planes on MR imaging should be carefully evaluated to identify tears of the subscapularis, retraction, atrophy and biceps pathology. Due to the tendency of the tendon to retract medially, acute and traumatic full-thickness tears should be repaired. Chronic tears without significant degeneration should be considered for repair if no contraindication exists. Arthroscopic repair can be performed using a 30-degree arthroscope and a laterally-based single row repair; one anchor for full thickness tears ⩽ 50% of tendon length and two anchors for those ⩾ 50% of tendon length. Biceps pathology, which is invariably present, should be addressed by tenotomy or tenodesis. Timing of post-operative rehabilitation is dictated by the size of the repair and the security of the repair construct. The stages of rehabilitation typically involve a period of immobilisation followed by range of movement exercises, with a delay in active internal rotation (IR) and strengthening in IR. Cite this article: EFORT Open Rev 2017;2:484–495. DOI: 10.1302/2058-5241.2.170015 PMID:29387471

  8. Enhanced Tendon-to-Bone Healing of Chronic Rotator Cuff Tears by Bone Marrow Aspirate Concentrate in a Rabbit Model

    PubMed Central

    Liu, Xiao Ning; Yang, Cheol-Jung; Kim, Ji Eui; Du, Zhen Wu; Ren, Ming; Zhang, Wei; Zhao, Hong Yu; Kim, Kyung Ok

    2018-01-01

    Background To evaluate the influence of bone marrow aspirate concentrate (BMAC) on tendon-to-bone healing in a rabbit rotator cuff model and to characterize the composition of growth factors in BMAC. Methods In this in vivo study, 40 rabbits were allocated into five groups: control (C), repair + saline (RS), repair + platelet-rich plasma (PRP; RP), repair + BMAC (RB) and repair + PRP + BMAC (RPB). A tear model was created by supraspinatus tendon transection at the footprint. Six weeks after transection, the torn tendon was repaired along with BMAC or PRP administration. Six weeks after repair, shoulder samples were harvested for biomechanical and histological testing. Ten rabbits were used for processing PRP and BMAC, followed by analysis of blood cell composition and the levels of growth factors in vitro. Results The ultimate load-to-failure was significantly higher in RPB group compared to RS group (p = 0.025). BMAC-treated groups showed higher values of biomechanical properties than RS group. The histology of BMAC-treated samples showed better collagen fiber continuity and orientation than RS group. BMAC contained significantly higher levels of the several growth factors than PRP. Conclusions Locally administered BMAC enhanced tendon-to-bone healing and has potential for clinical applications. PMID:29564054

  9. Using the zebrafish to understand tendon development and repair

    PubMed Central

    Chen, Jessica W.; Galloway, Jenna L.

    2017-01-01

    Tendons are important components of our musculoskeletal system. Injuries to these tissues are very common, resulting from occupational-related injuries, sports-related trauma, and age-related degeneration. Unfortunately, there are few treatment options, and current therapies rarely restore injured tendons to their original function. An improved understanding of the pathways regulating their development and repair would have significant impact in stimulating the formulation of regenerative-based approaches for tendon injury. The zebrafish provides an ideal system in which to perform genetic and chemical screens to identify new pathways involved in tendon biology. Until recently, there had been few descriptions of tendons and ligaments in the zebrafish and their similarity to mammalian tendon tissues. In this chapter, we describe the development of the zebrafish tendon and ligament tissues in the context of their gene expression, structure, and interactions with neighboring musculoskeletal tissues. We highlight the similarities with tendon development in higher vertebrates, showing that the craniofacial tendons and ligaments in zebrafish morphologically, molecularly, and structurally resemble mammalian tendons and ligaments from embryonic to adult stages. We detail methods for fluorescent in situ hybridization and immunohistochemistry as an assay to examine morphological changes in the zebrafish musculoskeleton. Staining assays such as these could provide the foundation for screen-based approaches to identify new regulators of tendon development, morphogenesis, and repair. These discoveries would provide new targets and pathways to study in the context of regenerative medicine-based approaches to improve tendon healing. PMID:28129848

  10. Achilles Tendon Rupture: Avoiding Tendon Lengthening during Surgical Repair and Rehabilitation

    PubMed Central

    Maquirriain, Javier

    2011-01-01

    Achilles tendon rupture is a serious injury for which the best treatment is still controversial. Its primary goal should be to restore normal length and tension, thus obtaining an optimal function. Tendon elongation correlates significantly with clinical outcome; lengthening is an important cause of morbidity and may produce permanent functional impairment. In this article, we review all factors that may influence the repair, including the type of surgical technique, suture material, and rehabilitation program, among many others. PMID:21966048

  11. Effect of Footprint Preparation on Tendon-to-Bone Healing: A Histologic and Biomechanical Study in a Rat Rotator Cuff Repair Model.

    PubMed

    Nakagawa, Haruhiko; Morihara, Toru; Fujiwara, Hiroyoshi; Kabuto, Yukichi; Sukenari, Tsuyoshi; Kida, Yoshikazu; Furukawa, Ryuhei; Arai, Yuji; Matsuda, Ken-Ichi; Kawata, Mitsuhiro; Tanaka, Masaki; Kubo, Toshikazu

    2017-08-01

    To compare the histologic and biomechanical effects of 3 different footprint preparations for repair of tendon-to-bone insertions and to assess the behavior of bone marrow-derived cells in each method of insertion repair. We randomized 81 male Sprague-Dawley rats and green fluorescent protein-bone marrow chimeric rats into 3 groups. In group A, we performed rotator cuff repair after separating the supraspinatus tendon from the greater tuberosity and removing the residual tendon tissue. In group B, we also drilled 3 holes into the footprint. The native fibrocartilage was preserved in groups A and B. In group C, we excavated the footprint until the cancellous bone was exposed. Histologic repair of the tendon-to-bone insertion, behavior of the bone marrow-derived cells, and ultimate force to failure were examined postoperatively. The areas of metachromasia in groups A, B, and C were 0.033 ± 0.019, 0.089 ± 0.022, and 0.002 ± 0.001 mm 2 /mm 2 , respectively, at 4 weeks and 0.029 ± 0.022, 0.090 ± 0.039, and 0.003 ± 0.001 mm 2 /mm 2 , respectively, at 8 weeks. At 4 and 8 weeks postoperatively, significantly higher cartilage matrix production was observed in group B than in group C (4 weeks, P = .002; 8 weeks, P < .001). In green fluorescent protein-bone marrow chimeric rats in group B, bone marrow-derived chondrogenic cells infiltrated the fibrocartilage layer. Ultimate force to failure was significantly higher in group B (19.7 ± 3.4 N) than in group C (16.7 ± 2.0 N) at 8 weeks (P = .031). Drilling into the footprint and preserving the fibrocartilage improved the quality of repair tissue and biomechanical strength at the tendon-to-bone insertion after rotator cuff repair in an animal model. Drilling into the footprint and preserving the fibrocartilage can enhance repair of tendon-to-bone insertions. This method may be clinically useful in rotator cuff repair. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Articular Cartilage Increases Transition Zone Regeneration in Bone-tendon Junction Healing

    PubMed Central

    Qin, Ling; Lee, Kwong Man; Leung, Kwok Sui

    2008-01-01

    The fibrocartilage transition zone in the direct bone-tendon junction reduces stress concentration and protects the junction from failure. Unfortunately, bone-tendon junctions often heal without fibrocartilage transition zone regeneration. We hypothesized articular cartilage grafts could increase fibrocartilage transition zone regeneration. Using a goat partial patellectomy repair model, autologous articular cartilage was harvested from the excised distal third patella and interposed between the residual proximal two-thirds bone fragment and tendon during repair in 36 knees. We evaluated fibrocartilage transition zone regeneration, bone formation, and mechanical strength after repair at 6, 12, and 24 weeks and compared them with direct repair. Autologous articular cartilage interposition resulted in more fibrocartilage transition zone regeneration (69.10% ± 14.11% [mean ± standard deviation] versus 8.67% ± 7.01% at 24 weeks) than direct repair at all times. There was no difference in the amount of bone formation and mechanical strength achieved. Autologous articular cartilage interposition increases fibrocartilage transition zone regeneration in bone-tendon junction healing, but additional research is required to ascertain the mechanism of stimulation and to establish the clinical applicability. PMID:18987921

  13. Efficacy of Low Level Laser Therapy After Hand Flexor Tendon Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayad, K. E.; Abd El Mejeed, S. F.; El Gohary, H. M.

    Flexor tendon injury is a common problem requiring suturing repair followed by early postoperative mobilization. Muscle atrophy, joint stiffness, osteoarthritis, infection, skin necrosis, ulceration of joint cartilage and tendocutaneous adhesion are familiar complications produced by prolonged immobilization of surgically repaired tendon ruptures. The purpose of this study was to clarify the importance of low level laser therapy after hand flexor tendon repair in zone II. Thirty patients aging between 20 and 40 years were divided into two groups. Patients in group A (n = 15) received a conventional therapeutic exercise program while patients in group B (n = 15) receivedmore » low level laser therapy combined with the same therapeutic exercise program. The results showed a statistically significant increase in total active motion of the proximal and distal interphalangeal joints as well as maximum hand grip strength at three weeks and three months postoperative, but improvement was more significant in group B. It was concluded that the combination of low level laser therapy and early therapeutic exercises was more effective than therapeutic exercises alone in improving total active motion of proximal and distal interphalangeal joints and hand grip strength after hand flexor tendon repair.« less

  14. Influence of different length of core suture purchase among suture row on the strength of 6-strand tendon repairs.

    PubMed

    Okubo, Hirotaka; Kusano, Nozomu; Kinjo, Masaki; Kanaya, Fuminori

    2015-01-01

    In multi-strand suture methods consisting of several suture rows, the different length of core suture purchase between each suture row may affect the strength of repairs. We evaluated the influence of the different length of core suture purchase between each suture row on the strength of 6-strand tendon repairs. Rabbit flexor tendons were repaired by using a triple-looped suture technique in which the suture purchase length in each suture row was modified. Group 1, all lengths are 8-mm. Group 2, all lengths are 10-mm. Group 3, two are 10-mm and one is 8-mm. Group 4, one is 10-mm and two are 8-mm. The repaired tendons were subjected to load-to-failure test. The gap strength was significantly greater in Group 1 and Group 2 than in Group 3 and Group 4. This study demonstrates that maintaining equal core suture purchase lengths of each suture row increases the gap resistance.

  15. Bridging suture makes consistent and secure fixation in double-row rotator cuff repair.

    PubMed

    Fukuhara, Tetsutaro; Mihata, Teruhisa; Jun, Bong Jae; Neo, Masashi

    2017-09-01

    Inconsistent tension distribution may decrease the biomechanical properties of the rotator cuff tendon after double-row repair, resulting in repair failure. The purpose of this study was to compare the tension distribution along the repaired rotator cuff tendon among three double-row repair techniques. In each of 42 fresh-frozen porcine shoulders, a simulated infraspinatus tendon tear was repaired by using 1 of 3 double-row techniques: (1) conventional double-row repair (no bridging suture); (2) transosseous-equivalent repair (bridging suture alone); and (3) compression double-row repair (which combined conventional double-row and bridging sutures). Each specimen underwent cyclic testing at a simulated shoulder abduction angle of 0° or 40° on a material-testing machine. Gap formation and tendon strain were measured during the 1st and 30th cycles. To evaluate tension distribution after cuff repair, difference in gap and tendon strain between the superior and inferior fixations was compared among three double-row techniques. At an abduction angle of 0°, gap formation after either transosseous-equivalent or compression double-row repair was significantly less than that after conventional double-row repair (p < 0.01). During the 30th cycle, both transosseous-equivalent repair (p = 0.02) and compression double-row repair (p = 0.01) at 0° abduction had significantly less difference in gap formation between the superior and inferior fixations than did conventional double-row repair. After the 30th cycle, the difference in longitudinal strain between the superior and inferior fixations at 0° abduction was significantly less with compression double-row repair (2.7% ± 2.4%) than with conventional double-row repair (8.6% ± 5.5%, p = 0.03). Bridging sutures facilitate consistent and secure fixation in double-row rotator cuff repairs, suggesting that bridging sutures may be beneficial for distributing tension equally among all sutures during double-row repair of rotator cuff tears. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  16. The role of animal models in tendon research

    PubMed Central

    Hast, M. W.; Zuskov, A.; Soslowsky, L. J.

    2014-01-01

    Tendinopathy is a debilitating musculoskeletal condition which can cause significant pain and lead to complete rupture of the tendon, which often requires surgical repair. Due in part to the large spectrum of tendon pathologies, these disorders continue to be a clinical challenge. Animal models are often used in this field of research as they offer an attractive framework to examine the cascade of processes that occur throughout both tendon pathology and repair. This review discusses the structural, mechanical, and biological changes that occur throughout tendon pathology in animal models, as well as strategies for the improvement of tendon healing. Cite this article: Bone Joint Res 2014;3:193–202. PMID:24958818

  17. Nickel-titanium wire as a flexor tendon suture material: an ex vivo study.

    PubMed

    Karjalainen, T; Göransson, H; Viinikainen, A; Jämsä, T; Ryhänen, J

    2010-07-01

    Nickel-titanium shape memory alloy (NiTi) is a new suture material that is easy to handle, is strong, and biocompatible. The purpose of this study was to evaluate the material properties and biomechanical behaviour of 150 microm and 200 microm NiTi wires in flexor tendon repair. Braided polyester (4-0 Ethibond) was used as control. Fifty fresh-frozen porcine flexor tendons were repaired using the Pennington modification of the Kessler repair or a double Kessler technique. NiTi wires were stiffer and reached higher tensile strength compared to braided polyester suture. Repairs with 200 microm NiTi wire had a higher yield force, ultimate force and better resistance to gapping than 4-0 braided polyester repairs. Repairs made with 200 microm NiTi wire achieved higher stiffness and ultimate force than repairs made with 150 microm NiTi wire.

  18. Fixation of the Achilles tendon insertion using suture button technology.

    PubMed

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  19. Percutaneous Repair Technique for Acute Achilles Tendon Rupture with Assistance of Kirschner Wire.

    PubMed

    He, Ze-yang; Chai, Ming-xiang; Liu, Yue-ju; Zhang, Xiao-ran; Zhang, Tao; Song, Lian-xin; Ren, Zhi-xin; Wu, Xi-rui

    2015-11-01

    The aim of this study is to introduce a self-designed, minimally invasive technique for repairing an acute Achilles tendon rupture percutaneously. Comparing with the traditional open repair, the new technique provides obvious advantages of minimized operation-related lesions, fewer wound complications as well as a higher healing rate. However, a percutaneous technique without direct vision may be criticized by its insufficient anastomosis of Achilles tendon and may also lead to the lengthening of the Achilles tendon and a reduction in the strength of the gastrocnemius. To address the potential problems, we have improved our technique using a percutaneous Kirschner wire leverage process before suturing, which can effectively recover the length of the Achilles tendon and ensure the broken ends are in tight contact. With this improvement in technique, we have great confidence that it will become the treatment of choice for acute Achilles tendon ruptures. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  20. [Homeostasis and Disorder of Musculoskeletal System.Enthesis formation and repair:Current understanding and perspectives for the future regenerative therapy.

    PubMed

    Tokunaga, Takuya; Arimura, Hitoshi; Mizuta, Hiroshi; Hiraki, Yuji; Shukunami, Chisa

    Tendons and ligaments are dense fibrous connective tissues mainly composed of type I collagen, aligned in highly ordered arrays along the axis of the tendon and ligament. The enthesis is defined as the attachment site of a tendon, ligament, joint capsule, or fascia to bone. During morphogenesis, the cell population co-expressing Scleraxis(Scx)and the SRY-box containing gene 9(Sox9)contributes to the formation of fibrocartilaginous entheses. Scx regulates tendon and ligament maturation, while Sox9 is a key regulatory factor for cartilage formation. The considerable mechanical forces transmitted through the enthesis and avascular properties of the tissue make it more prone to injuries and degenerative changes. Thus, integration of tendons or ligaments with bone following surgical repair remains a clinical challenge. In this review, we summarize the current knowledge regarding the formation, maintenance, damage, and repair of fibrocartilaginous entheses, focusing on the rotator cuff tendon-to-bone attachment sites.

  1. Isolated Subscapularis Repair in Irreparable Posterosuperior Massive Rotator Cuff Tears Involving the Subscapularis Tendon.

    PubMed

    Kim, Sung-Jae; Choi, Yun-Rak; Jung, Min; Lee, Won-Yong; Chun, Yong-Min

    2017-05-01

    No previous study has examined whether isolated subscapularis tendon repair in irreparable posterosuperior massive rotator tears involving the subscapularis tendon in relatively young patients without arthritis can yield satisfactory outcomes. We hypothesized that this procedure would produce favorable outcomes in patients who might otherwise be candidates for reverse arthroplasty. Case series; Level of evidence, 4. This retrospective study included 24 patients in their 50s and 60s, without shoulder arthritis, who underwent arthroscopic isolated subscapularis repair for an irreparable massive rotator cuff tear involving the subscapularis tendon. Preoperative and postoperative visual analog scale (VAS) pain scores, subjective shoulder values (SSVs), University of California at Los Angeles (UCLA) shoulder scores, American Shoulder and Elbow Surgeons (ASES) scores, subscapularis strength (modified bell-press test; maximum of 5), and shoulder active range of motion (ROM) were assessed. Postoperative magnetic resonance arthrography (MRA) was performed 6 months postoperatively to assess structural integrity of the repaired subscapularis. At a mean 34.8 months (range, 24-49 months) of follow-up, VAS pain scores (improved from 7.1 to 2.5), SSVs (33.3 to 75.2), ASES scores (35.9 to 76.0), UCLA shoulder scores (11.6 to 24.8), subscapularis strength, and ROM were significantly improved compared with preoperative measurements ( P < .001). Subscapularis muscle strength improved from 3.7 to 4.2 ( P < .001). For active ROM, forward flexion and internal rotation improved significantly ( P < .001); however, external rotation exhibited no significant improvement. Follow-up MRA was performed in 22 patients (92%) and showed retear of the repaired subscapularis in 6 (27% of the 22). Isolated repair of the subscapularis tendon in irreparable massive rotator cuff tears involving the subscapularis tendon yielded satisfactory short-term outcomes and structural integrity in patients in their 50s and 60s without arthritis. If patients with irreparable massive rotator cuff tears involving the subscapularis tendon are relatively young or have minimal concomitant arthritis, this repair can be worthwhile.

  2. Longitudinal Long-term Magnetic Resonance Imaging and Clinical Follow-up After Single-Row Arthroscopic Rotator Cuff Repair: Clinical Superiority of Structural Tendon Integrity.

    PubMed

    Heuberer, Philipp R; Smolen, Daniel; Pauzenberger, Leo; Plachel, Fabian; Salem, Sylvia; Laky, Brenda; Kriegleder, Bernhard; Anderl, Werner

    2017-05-01

    The number of arthroscopic rotator cuff surgeries is consistently increasing. Although generally considered successful, the reported number of retears after rotator cuff repair is substantial. Short-term clinical outcomes are reported to be rarely impaired by tendon retears, whereas to our knowledge, there is no study documenting long-term clinical outcomes and tendon integrity after arthroscopic rotator cuff repair. To investigate longitudinal long-term repair integrity and clinical outcomes after arthroscopic rotator cuff reconstruction. Case series; Level of evidence, 4. Thirty patients who underwent arthroscopic rotator cuff repair with suture anchors for a full-tendon full-thickness tear of the supraspinatus or a partial-tendon full-thickness tear of the infraspinatus were included. Two and 10 years after initial arthroscopic surgery, tendon integrity was analyzed using magnetic resonance imaging (MRI). The University of California, Los Angeles (UCLA) score and Constant score as well as subjective questions regarding satisfaction with the procedure and return to normal activity were used to evaluate short- and long-term outcomes. At the early MRI follow-up, 42% of patients showed a full-thickness rerupture, while 25% had a partial rerupture, and 33% of tendons remained intact. The 10-year MRI follow-up (129 ± 11 months) showed 50% with a total rerupture, while the other half of the tendons were partially reruptured (25%) or intact (25%). The UCLA and Constant scores significantly improved from preoperatively (UCLA total: 50.6% ± 20.2%; Constant total: 44.7 ± 10.5 points) to 2 years (UCLA total: 91.4% ± 16.0% [ P < .001]; Constant total: 87.8 ± 15.3 points [ P < .001]) and remained significantly higher after 10 years (UCLA total: 89.7% ± 15.9% [ P < .001]; Constant total: 77.5 ± 15.6 points [ P < .001]). The Constant total score and Constant strength subscore, but not the UCLA score, were also significantly better at 10 years postoperatively in patients with intact tendons compared with patients with retorn tendons (Constant total: 89.0 ± 7.8 points vs 75.7 ± 14.1 points, respectively [ P = .034]; Constant strength: 18.0 ± 4.9 points vs 9.2 ± 5.2 points, respectively [ P = .006]). The majority of patients rated their satisfaction with the procedure as "excellent" (83.3%), and 87.5% returned to their normal daily activities. Arthroscopic rotator cuff repair showed good clinical long-term results despite a high rate of retears. Nonetheless, intact tendons provided significantly superior clinical long-term outcomes, making the improvement of tendon healing and repair integrity important goals of future research efforts.

  3. A rare knee extensor mechanism injury: Vastus intermedius tendon rupture.

    PubMed

    Cetinkaya, Engin; Aydin, Canan Gonen; Akman, Yunus Emre; Gul, Murat; Arikan, Yavuz; Aycan, Osman Emre; Kabukcuoglu, Yavuz Selim

    2015-01-01

    Quadriceps tendon injuries are rare. There is a limited number of studies in the literature, reporting partial quadriceps tendon ruptures. We did not find any study reporting an isolated vastus intermedius tendon injury in the literature. A 22 years old professional rugby player with the complaints of pain in the right lower limb, decreased range of motion in right knee and a mass in the mid-anterior of the right thigh applied following an overloading on his hyperflexed knee during a rugby match. T2 sequence magnetic resonance images revealed discontinuity in the vastus intermedius tendon and intramuscular hematoma. The patient has been conservatively treated. Quadriceps tendon ruptures generally occur after the 4th decade in the presence of degenerative changes. Our case is a young professional rugby player. Isolated vastus intermedius tendon rupture is unusual. Conservative treatment is performed as the intermedius tendon is in the deepest layer of the quadriceps muscle. We report the first case of isolated rupture of the vastus intermedius tendon in the literature and we claim that disorder may be succesfully treated with conservative treatment and adequate physiotheraphy. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. A rare knee extensor mechanism injury: Vastus intermedius tendon rupture

    PubMed Central

    Cetinkaya, Engin; Aydin, Canan Gonen; Akman, Yunus Emre; Gul, Murat; Arikan, Yavuz; Aycan, Osman Emre; Kabukcuoglu, Yavuz Selim

    2015-01-01

    Introduction Quadriceps tendon injuries are rare. There is a limited number of studies in the literature, reporting partial quadriceps tendon ruptures. We did not find any study reporting an isolated vastus intermedius tendon injury in the literature. Presentation of case A 22 years old professional rugby player with the complaints of pain in the right lower limb, decreased range of motion in right knee and a mass in the mid-anterior of the right thigh applied following an overloading on his hyperflexed knee during a rugby match. T2 sequence magnetic resonance images revealed discontinuity in the vastus intermedius tendon and intramuscular hematoma. The patient has been conservatively treated. Discussion Quadriceps tendon ruptures generally occur after the 4th decade in the presence of degenerative changes. Our case is a young professional rugby player. Isolated vastus intermedius tendon rupture is unusual. Conservative treatment is performed as the intermedius tendon is in the deepest layer of the quadriceps muscle. Conclusion We report the first case of isolated rupture of the vastus intermedius tendon in the literature and we claim that disorder may be succesfully treated with conservative treatment and adequate physiotheraphy. PMID:26298093

  5. Biologics for tendon repair☆

    PubMed Central

    Docheva, Denitsa; Müller, Sebastian A.; Majewski, Martin; Evans, Christopher H.

    2015-01-01

    Tendon injuries are common and present a clinical challenge to orthopedic surgery mainly because these injuries often respond poorly to treatment and require prolonged rehabilitation. Therapeutic options used to repair ruptured tendons have consisted of suture, autografts, allografts, and synthetic prostheses. To date, none of these alternatives has provided a successful long-term solution, and often the restored tendons do not recover their complete strength and functionality. Unfortunately, our understanding of tendon biology lags far behind that of other musculoskeletal tissues, thus impeding the development of new treatment options for tendon conditions. Hence, in this review, after introducing the clinical significance of tendon diseases and the present understanding of tendon biology, we describe and critically assess the current strategies for enhancing tendon repair by biological means. These consist mainly of applying growth factors, stem cells, natural biomaterials and genes, alone or in combination, to the site of tendon damage. A deeper understanding of how tendon tissue and cells operate, combined with practical applications of modern molecular and cellular tools could provide the long awaited breakthrough in designing effective tendon-specific therapeutics and overall improvement of tendon disease management. PMID:25446135

  6. Surgical Treatment for Failure of Repair of Patellar and Quadriceps Tendon Rupture With Ipsilateral Hamstring Tendon Graft.

    PubMed

    Maffulli, Nicola; Papalia, Rocco; Torre, Guglielmo; Denaro, Vincenzo

    2017-03-01

    Tears of the patellar and quadriceps tendon are common in the active population, especially in athletes. At present, several techniques for surgical repair and reconstruction are available. When reruptures occur, a reconstruction is mandatory. In the present paper, we describe a surgical technique for patellar and quadriceps tendon reconstruction using ipsilateral hamstring autograft. After routine hamstring tendon harvesting, the tendon ends are prepared using a whip stitch. A transverse tunnel is drilled in the midportion of the patella, the hamstring graft is passed through the patella, and firmly secured to the patellar tunnel openings with sutures. The details of the technique are fully described. Autologous ipsilateral hamstring tendon grafts provide a secure sound means to manage these challenging injuries.

  7. Biomechanical Evaluation of Suture Anchor Versus Transosseous Tunnel Quadriceps Tendon Repair Techniques.

    PubMed

    Sherman, Seth L; Copeland, Marilyn E; Milles, Jeffrey L; Flood, David A; Pfeiffer, Ferris M

    2016-06-01

    To evaluate the biomechanical fixation strength of suture anchor and transosseous tunnel repair of the quadriceps tendon in a standardized cadaveric repair model. Twelve "patella-only" specimens were used. Dual-energy X-ray absorptiometry measurement was performed to ensure equal bone quality amongst groups. Specimens were randomly assigned to either a suture anchor repair of quadriceps tendon group (n = 6) or a transosseous tunnel repair group (n = 6). Suture type and repair configuration were equivalent. After the respective procedures were performed, each patella was mounted into a gripping jig. Tensile load was applied at a rate of 0.1 mm/s up to 100 N after which cyclic loading was applied at a rate of 1 Hz between magnitudes of 50 to 150 N, 50 to 200 N, 50 to 250 N, and tensile load at a rate of 0.1 mm/s until failure. Outcome measures included load to failure, displacement at 1st 100 N load, and displacement after each 10th cycle of loading. The measured cyclic displacement to the first 100 N, 50 to 150 N, 50 to 200 N, and 50 to 250 N was significantly less for suture anchors than transosseous tunnels. There was no statistically significant difference in ultimate load to failure between the 2 groups (P = .40). Failure mode for all suture anchors except one was through the soft tissue. Failure mode for all transosseous specimens but one was pulling the repair through the transosseous tunnel. Suture anchor quadriceps tendon repairs had significantly decreased gapping during cyclic loading, but no statistically significant difference in ultimate load to failure when compared with transosseous tunnel repairs. Although suture anchor quadriceps tendon repair appears to be a biomechanically superior construct, a clinical study is needed to confirm this technique as a viable alternative to gold standard transosseous techniques. Although in vivo studies are needed, these results support the suture anchor technique as a viable alternative to transosseous repair of the quadriceps tendon. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Restoration of shoulder biomechanics according to degree of repair completion in a cadaveric model of massive rotator cuff tear: importance of margin convergence and posterior cuff fixation.

    PubMed

    Oh, Joo Han; McGarry, Michelle H; Jun, Bong Jae; Gupta, Akash; Chung, Kyung Chil; Hwang, James; Lee, Thay Q

    2012-11-01

    Complete repair in massive rotator cuff tear may not be possible, allowing for only partial repair. However, the effect of partial repair on glenohumeral biomechanics has not been evaluated. Therefore, the purpose of this study was to compare the rotational range of motion (ROM), glenohumeral kinematics, and gap formation at the repaired tendon edge following massive cuff tear and repair according to the degree of repair completion. Posterior fixation will restore the altered biomechanics of massive rotator cuff tear. Controlled laboratory study. Eight cadaveric shoulders were tested at 0°, 30°, and 60° of abduction in the scapular plane. Muscle loading was applied based on physiological muscle cross-sectional area ratios. Maximum internal (MaxIR) and external rotations (MaxER) were measured. Humeral head apex (HHA) position and gap formation at the repaired tendon edge were measured using a MicroScribe from MaxIR to MaxER in 30° increments. Testing was performed for intact, massive cuff tear, complete repair, and 4 types of partial repair. A repeated-measures analysis of variance was used to determine significant differences. Massive tear significantly increased ROM and shifted HHA superiorly in MaxIR at all abduction angles (P < .05). The complete repair restored ROM to intact (P < .05), while all partial repairs did not. Abnormal HHA elevation due to massive tear was restored by all repairs (P < .05). Release of the anterior single row alone and release of the marginal convergence significantly increased gap formation at the anterior tendon edge (P < .05). This study emphasizes the importance of anterior fixation in massive cuff tear to restore rotational range of motion and decrease gap formation at the repaired tendon edge and of posterior fixation to restore abnormal glenohumeral kinematics due to massive cuff tear. If complete repair of massive cuff tear is not possible, posterior cuff (infraspinatus) repair is necessary to restore abnormal glenohumeral kinematics, and margin convergence anteriorly is recommended to decrease gap formation of the repaired tendon edge, which may provide a better biomechanical environment for healing.

  9. A Load-Sharing Rip-Stop Fixation Construct for Arthroscopic Rotator Cuff Repair

    PubMed Central

    Denard, Patrick J.; Burkhart, Stephen S.

    2012-01-01

    Despite advancements in arthroscopic rotator cuff repair techniques, achieving tendon-to-bone healing can be difficult in the setting of poor-quality tendon. Moreover, medial tendon tears or tears with lateral tendon loss may preclude standard techniques. Rip-stop suture configurations have been shown to improve load to failure compared with simple or mattress stitch patterns and may be particularly valuable in these settings. The purpose of this report is to describe a technical modification of a rip-stop rotator cuff repair that combines the advantages of a rip-stop suture (by providing resistance to tissue cutout) and a double row of load-sharing suture anchors (minimizing the load per anchor and therefore the load per suture within each anchor). PMID:23766972

  10. Muscular responses appear to be associated with existence of kinesthetic perception during combination of tendon co-vibration and motor imagery.

    PubMed

    Shibata, Eriko; Kaneko, Fuminari; Katayose, Masaki

    2017-11-01

    The afferent inputs from peripheral sensory receptors and efferent signals from the central nervous system that underlie intentional movement can contribute to kinesthetic perception. Previous studies have revealed that tendon vibration to wrist muscles elicits an excitatory response-known as the antagonist vibratory response-in muscles antagonistic to the vibrated muscles. Therefore, the present study aimed to further investigate the effect of tendon vibration combined with motor imagery on kinesthetic perception and muscular activation. Two vibrators were applied to the tendons of the left flexor carpi radialis and extensor carpi radialis. When the vibration frequency was the same between flexors and extensors, no participant perceived movement and no muscle activity was induced. When participants imagined flexing their wrists during tendon vibration, the velocity of perceptual flexion movement increased. Furthermore, muscle activity of the flexor increased only during motor imagery. These results demonstrate that kinesthetic perception can be induced during the combination of motor imagery and co-vibration, even with no experience of kinesthetic perception from an afferent input with co-vibration at the same frequency. Although motor responses were observed during combined co-vibration and motor imagery, no such motor responses were recorded during either co-vibration alone or motor imagery alone, suggesting that muscular responses during the combined condition are associated with kinesthetic perception. Thus, the present findings indicate that kinesthetic perception is influenced by the interaction between afferent input from muscle spindles and the efferent signals that underlie intentional movement. We propose that the physiological behavior resulting from kinesthetic perception affects the process of modifying agonist muscle activity, which will be investigated in a future study.

  11. Ultrasonography of the distal limbs in Nellore and Girolando calves 8 to 12 months of age

    PubMed Central

    2014-01-01

    Background Ultrasonography can be used anywhere and allows rapid, noninvasive differentiation of soft tissue structures of the musculoskeletal system. The objectives of this study were to describe the ultrasonographic appearance of the structures of the metacarpo-/metatarsophalangeal and the interphalangeal joints, the appearance of the growth plates of the distal metacarpus/metatarsus and of the proximal phalanx and to measure the cross-sectional dimensions of the DDFT and SDFT in Nellore and Girolando calves eight to 12 months of age. Results In the longitudinal dorsal view the common digital extensor tendon and the digital extensor tendon were depicted as echogenic parallel fiber bundles located directly under the skin. The joint spaces appeared as anechoic interruptions of the hyperechogenic bone surfaces. The normal amount of synovial fluid could not be depicted. The growth plates were seen as anechoic interruptions of the bone surface proximal and distal to the fetlock joint space. In transverse sonograms of the distal palmar/plantar regions, the flexor tendons and branchs of the suspensory ligament were imaged as echogenic structures. The lumen of the digital flexor tendon sheath could not be imaged in these normal cattle. The thin digital distal annular ligament and the reversal of positions of the DDFT and SDFT could be appreciated. No significant differences were found between the cross-sectional measurements of the DDFT and the SDFT from Nellore and Girolando in any age, thoracic/pelvic limbs, right/left sides and lateral/medial digits. Conclusions The results of this study establish important ultrasonographic reference data of the normal structures of the distal limbs and the normal dimensions of the flexor tendons in Nellore and Girolando calves for use in clinical practice. PMID:24774582

  12. Efficacy of bone marrow-stimulating technique in rotator cuff repair.

    PubMed

    Bilsel, Kerem; Yildiz, Fatih; Kapicioglu, Mehmet; Uzer, Gokcer; Elmadag, Mehmet; Pulatkan, Anil; Esrefoglu, Mukaddes; Bozdag, Ergun; Milano, Giuseppe

    2017-08-01

    This study used a chronic rotator cuff (RC) tear model to investigate the effect of microfracture as a bone marrow-stimulating (BMS) technique for RC healing. A chronic retracted RC tendon tear model was created bilaterally in the subscapularis tendons of 20 New Zealand rabbits. The tendons were repaired after 8 weeks using a single-row configuration. Tendons in the right shoulder were repaired in standard fashion (control group). Microfractures were performed in the left shoulders before repair (microfracture group). The animals were euthanized 8 and 16 weeks after repair. The repaired tendons were tested biomechanically for their ultimate failure load, linear stiffness, and elongation at failure. Gross and histologic evaluations of the tendon-to-bone healing were evaluated. Macroscopically, subscapularis tendons were attached on the lesser tuberosity. In the microfracture group, collagen fibers were organized in relatively thicker bundles. The mean ultimate failure load of the microfracture group was significantly greater at 8 weeks (148.4 ± 31 N vs. 101.4 ± 26 N, respectively; P = .011) and 16 weeks (155 ± 30 N vs. 114.9 ± 25 N, respectively; P = .017) after repair. There were no significant differences between the groups for linear stiffness at 8 weeks (15.9 ± 2.7 N/mm vs. 15.8 ± 1.3 N/mm, respectively; P = .798) and 16 weeks (16.9 ± 4.3 N/mm vs. 17.1 ± 3.6 N/mm, respectively, P = .848) and elongation at failure at 8 weeks (4.7 ± 1.1 mm vs. 4.7 ± 1.3 mm, respectively; P = .848) and 16 weels (4.8 ± 1.5 mm vs. 4.9 ± 0.9 mm, respectively; P = .749). The microfracture on the tuberosity of the repaired chronic rotator cuff tear promoted dynamic tendon healing with significantly increased ultimate force to failure and with thicker collagen bundles and more fibrocartilage histologically at 8 weeks. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. The Gift Box Open Achilles Tendon Repair Method: A Retrospective Clinical Series.

    PubMed

    Labib, Sameh A; Hoffler, C Edward; Shah, Jay N; Rolf, Robert H; Tingan, Alexis

    2016-01-01

    Previous biomechanical studies have shown that the gift box technique for open Achilles tendon repair is twice as strong as a Krackow repair. The technique incorporates a paramedian skin incision with a midline paratenon incision, and a modification of the Krackow stitch is used to reinforce the repair. The wound is closed in layers such that the paratenon repair is offset from paramedian skin incision, further protecting the repair. The present study retrospectively reviews the clinical results for a series of patients who underwent the gift box technique for treatment of acute Achilles tendon ruptures from March 2002 to April 2007. The patients completed the Foot Function Index and the American Orthopaedic Foot and Ankle Society ankle-hindfoot scale. The tendon width and calf circumference were measured bilaterally and compared using paired t tests with a 5% α level. A total of 44 subjects, mean age 37.5 ± 8.6 years, underwent surgery approximately 10.8 ± 6.5 days after injury. The response rate was 35 (79.54%) patients for the questionnaire and 20 (45.45%) for the examination. The mean follow-up period was 35.7 ± 20.1 months. The complications included one stitch abscess, persistent pain, and keloid formation. One (2.86%) respondent reported significant weakness. Five (14.29%) respondents indicated persistent peri-incisional numbness. The range of motion was full or adequate. The mean American Orthopaedic Foot and Ankle Society ankle-hindfoot scale score was 93.2 ± 6.8) and the mean Foot Function Index score was 7.0 ± 10.5. The calf girth and tendon width differences were statistically significantly between the limbs. The patients reported no repeat ruptures, sural nerve injuries, dehiscence, or infections. We present the outcomes data from patients who had undergone this alternative technique for Achilles tendon repair. The technique is reproducible, with good patient satisfaction and return to activity. The results compared well with the historical repeat rupture rates and incidence of nerve injury and dehiscence for open and percutaneous Achilles tendon repairs. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Triceps Ruptures After Fluoroquinolone Antibiotics: A Report of 2 Cases.

    PubMed

    Shybut, Theodore B; Puckett, Ernest R

    Rupture of the triceps brachii tendon is exceedingly rare, and surgical repair is generally indicated. Fluoroquinolone antibiotics have been implicated in tendon pathology, including tendon ruptures. Triceps rupture has not been previously reported in the setting of fluoroquinolone antibiotic therapy. We present 2 cases of triceps tendon rupture after treatment with fluoroquinolones. In both cases, triceps repair was performed with good outcomes. These cases highlight a risk of fluoroquinolone-induced tendinopathy to athletes. The sports medicine team should be aware of this risk and consider it when choosing antibiotics to treat athletes.

  15. Successful conservative treatment outcomes and clinical characteristics of congenital hypoplasia of the extensor tendon central slip.

    PubMed

    Hidaka, N; Uemura, T; Nakamura, H

    2017-03-01

    Congenital hypoplasia of the extensor tendon central slip is a rare entity. This article describes the clinical characteristics in a series of 22 fingers in 16 patients (mean age: 10 months), and the outcomes of conservative treatment. Nine of 22 fingers were classified as slender or hypoplastic. Treatment with bracing was successful in 21 digits, resulting in full active extension of the proximal interphalangeal joint at a mean of 8.5 months after treatment. Bracing was unsuccessful in one digit, in which operative treatment resulted in a successful outcome. Some residual deformity was observed in ten fingers after a mean follow-up period of 2 years and 1 month. Congenital hypoplasia of the central slip can be treated successfully by the conservative hand bracing when worn with full compliance. Treatment time is extended by the infrequent application of the hand brace or in the case of hypoplastic slender fingers. IV.

  16. Healing of rotator cuff tendons using botulinum toxin A and immobilization in a rat model.

    PubMed

    Gilotra, Mohit N; Shorofsky, Michael J; Stein, Jason A; Murthi, Anand M

    2016-03-15

    We evaluated effects of botulinum toxin A (Botox) and cast immobilization on tendon healing in a rat model. Injection of Botox into rat supraspinatus was hypothesized to reduce muscle active force and improved healing. Eighty-four supraspinatus tendons were surgically transected and repaired in 42 Sprague-Dawley rats (transosseous technique). After repair, supraspinatus muscle was injected with saline or Botox (3 or 6 U/kg). Half the shoulders were cast-immobilized for the entire postoperative period; half were allowed free cage activity. Histology was examined at 2, 4, 8, and 12 weeks. A healing zone cross-sectional area was measured, and biomechanical testing of repair strength and tendon viscoelastic properties was conducted at 4 and 12 weeks. Botox alone and cast immobilization alone exhibited increased ultimate load compared with controls (saline injection, no immobilization) at 4 weeks. No difference in ultimate load occurred between Botox-only and cast-only groups. At 12 weeks, the Botox (6 U/kg) plus cast immobilization group was significantly weakest (p < 0.05). A trend was shown toward decreased healing zone cross-sectional areas in casted groups. Supraspinatus Botox injection after rotator cuff repair might help protect the repair. However, cast immobilization plus Botox administration is harmful to rotator cuff healing in a rat tendon model.

  17. Effect of Poloxamer 407 as a carrier vehicle on rotator cuff healing in a rat model

    PubMed Central

    2014-01-01

    Background In vivo studies showing the effects of biologic healing-promoting factors on tendon-to-bone healing after rotator cuff repair have focused only on biologic healing-promoting factors and have not taken into consideration the effect of the carrier vehicle. Moreover, most studies have evaluated the healing process using different carrier vehicles, each of which may have specific effects on tendon healing. This may explain the large variability seen in outcomes in research studies. In this study, we investigated the effects of Poloxamer 407 as a carrier vehicle on rotator cuff healing at the repair site and compared it with those of a collagen sponge, which is a commonly used carrier vehicle. Methods Fifty-seven adult male Sprague–Dawley rats underwent detachment and immediate repair of the bilateral supraspinatus tendons. Rats were randomly assigned to three groups: repair only, repair with collagen sponge, and repair with Poloxamer 407. The repairs were evaluated at 1, 2, 4, and 8 weeks after surgery with histological analysis and biomechanical testing. Results At 4 weeks, more cellular organization, a greater number of collagen fibers, and increased maturity of collagen fibers were observed in the repair with Poloxamer 407 group than in the other groups. The repair with collagen sponge group had delayed development and collagen fiber maturation. Significant differences in the biomechanical properties were found between groups at 4 weeks. Stiffness in the case of the repair with Poloxamer 407 group was significantly higher than that in the repair with collagen sponge group. The modulus was significantly lower in the repair with collagen sponge group than in the repair only group. However, the use of Poloxamer 407 versus the collagen sponge did not significantly affect the biomechanical properties of the repaired tendons at 8 weeks. Conclusions Carrier vehicles may have differing effects at the early stages of rotator cuff healing. The use of Poloxamer 407 as a carrier vehicle may be useful for promoting the early stages of healing and for maintaining the initial biomechanical properties of the repaired rotator cuff tendon. PMID:24580752

  18. Effect of Poloxamer 407 as a carrier vehicle on rotator cuff healing in a rat model.

    PubMed

    Kim, Soung-Yon; Chae, Soo-Won; Lee, Juneyoung

    2014-03-01

    In vivo studies showing the effects of biologic healing-promoting factors on tendon-to-bone healing after rotator cuff repair have focused only on biologic healing-promoting factors and have not taken into consideration the effect of the carrier vehicle. Moreover, most studies have evaluated the healing process using different carrier vehicles, each of which may have specific effects on tendon healing. This may explain the large variability seen in outcomes in research studies. In this study, we investigated the effects of Poloxamer 407 as a carrier vehicle on rotator cuff healing at the repair site and compared it with those of a collagen sponge, which is a commonly used carrier vehicle. Fifty-seven adult male Sprague-Dawley rats underwent detachment and immediate repair of the bilateral supraspinatus tendons. Rats were randomly assigned to three groups: repair only, repair with collagen sponge, and repair with Poloxamer 407. The repairs were evaluated at 1, 2, 4, and 8 weeks after surgery with histological analysis and biomechanical testing. At 4 weeks, more cellular organization, a greater number of collagen fibers, and increased maturity of collagen fibers were observed in the repair with Poloxamer 407 group than in the other groups. The repair with collagen sponge group had delayed development and collagen fiber maturation. Significant differences in the biomechanical properties were found between groups at 4 weeks. Stiffness in the case of the repair with Poloxamer 407 group was significantly higher than that in the repair with collagen sponge group. The modulus was significantly lower in the repair with collagen sponge group than in the repair only group. However, the use of Poloxamer 407 versus the collagen sponge did not significantly affect the biomechanical properties of the repaired tendons at 8 weeks. Carrier vehicles may have differing effects at the early stages of rotator cuff healing. The use of Poloxamer 407 as a carrier vehicle may be useful for promoting the early stages of healing and for maintaining the initial biomechanical properties of the repaired rotator cuff tendon.

  19. Large Critical Shoulder Angle Has Higher Risk of Tendon Retear After Arthroscopic Rotator Cuff Repair.

    PubMed

    Li, Hong; Chen, Yuzhou; Chen, Jiwu; Hua, Yinghui; Chen, Shiyi

    2018-05-01

    The critical shoulder angle (CSA) is the angle created between the superior and inferior bone margins of the glenoid and the most lateral border of the acromion. A few studies recently investigated the relation between CSA and functional outcomes after rotator cuff repair. However, there is a lack of research investigating the effect of CSA on postoperative tendon integrity after rotator cuff repair. To assess the effects of the CSA on postoperative tendon integrity after rotator cuff repair. Cohort study; Level of evidence, 3. All patients who underwent rotator cuff repair for full-thickness supraspinatus tears by 1 senior surgeon between January 2010 and January 2014 were included in this study. All patients had standardized anteroposterior shoulder radiographs the day before surgery. CSA and acromial index (AI) were measured. AI was derived by measuring the distance from the glenoid plane to the lateral border of the acromion and dividing it by the distance from the glenoid plane to the lateral aspect of the humeral head. Functional scores-including American Shoulder and Elbow Surgeons shoulder evaluation form, modified University of California at Los Angeles score, Constant-Murley score, and visual analog scale for pain-were used to evaluate shoulder function at a minimum follow-up of 2 years. Meanwhile, magnetic resonance imaging examinations were performed to evaluate rotator cuff integrity according to the Sugaya method and the signal/noise quotient (SNQ) of the rotator cuff tendon. A total of 90 patients were included in this study: 42 patients with a single-row repair and 48 with a double-row repair. There was a significant positive correlation between CSA or AI and tendon SNQ. On the basis of CSA, the patients were divided into 2 groups: large CSA (>38°) and control (CSA ≤38°). At final follow-up, the large CSA group and the control CSA group demonstrated no significant differences in American Shoulder and Elbow Surgeons, University of California at Los Angeles, Constant, and visual analog scale scores. Postoperative magnetic resonance imaging revealed that the large CSA group had 9 cases of retear, with a significantly higher retear rate than the control group (15% vs 0%, P = .03). Furthermore, the tendon SNQ of the large CSA group was significantly greater than that of the control group. CSA did not appear to influence postoperative functional outcomes, while those in the large CSA group had poor tendon integrity after rotator cuff repair. These findings indicate that a large CSA is associated with an increased risk of rotator cuff tendon retear after repair.

  20. Ultrasound-guided minimally invasive surgery for achilles tendon rupture: preliminary results.

    PubMed

    Wang, Chen-Chie; Chen, Pei-Yu; Wang, Ting-Ming; Wang, Chung-Li

    2012-07-01

    Many surgeons prefer surgical repair for Achilles tendon ruptures in an attempt to reduce the risk of rerupture. To minimize wound complications, the use of minimally invasive surgery has become more popular recently. In line with this, the use of ultrasound to guide Achilles tendon repair is reported in this study. From March 2005 to January 2008, 23 patients with Achilles tendon rupture were repaired by the same surgeon. The ages of the patients ranged from 19 to 67 years old, with an average of 43 years old. The repair of the Achilles tendon was achieved through a stab wound under the guidance of ultrasonography. A control group consisted of 25 patients who received traditional open Achilles tendon repair. The average operation time was 52 minutes, and the average wound size was 1.1 cm. The short leg cast was removed 4 weeks after the surgery, and serial casting was used for another 3 to 4 weeks. The postoperative AOFAS ankle-hindfoot scores were 98.7 in the experimental group, 96.5 in the control group with no significant difference. The rates of local infection, stiffness of the ankle, pain of the scar and sural nerve injury were better in the experimental group than in the control group with significant difference. Ultrasound-guided surgery was a good choice due to its availability and real-time soft tissue visualization. It can further minimize the size of the surgical wound. Our method has the potential to achieve reliable results.

  1. Primary achilles tendon repair with mini-dorsolateral incision technique and accelerated rehabilitation.

    PubMed

    Hrnack, Scott A; Crates, John M; Barber, F Alan

    2012-10-01

    No consensus exists for the best primary repair of acute Achilles tendon ruptures. Problems with wound healing and nerve damage can occur. Prolonged immobilization leads to stiffness and calf atrophy. This study assesses the clinical outcome of acute Achilles tendon repairs using a mini-dorsolateral incision followed by a rapid rehabilitation program. A consecutive series of acute Achilles tendon ruptures repaired using a mini-dorsolateral incision were reviewed with a minimum 12 months follow up. Fifteen patients with an average age of 44 (range, 32 to 60) years were followed an average of 45 (range, 14 to 72) months. Two modified, buried core high strength sutures were placed in each torn end of the Achilles tendon reinforced with a running circumferential whip-stitch. Ankle Hindfoot scores, single toe raises, calf circumference, and adverse events were recorded. An accelerated postoperative rehabilitation protocol was followed. Postoperative AOFAS Ankle Hindfoot scores averaged 98.3 [39 pain; 49.6 function; 9.3 alignment]. All patients could single heel raise. Eight of 15 demonstrated atrophy with an average calf circumference loss of 1.0 cm. The only postoperative complication was one case of superficial cellulitis successfully treated with oral antibiotics. There were no sural nerve injuries, wound break down, or re-ruptures at final followup. The repair of acute Achilles tendon ruptures through a minimal lateral incision provided excellent functional outcomes, avoided complications including sural nerve injury, and allowed a return to sports between 4 to 6 months.

  2. P2 porous titanium implants improve tendon healing in an acute rat supraspinatus repair model.

    PubMed

    Tucker, Jennica J; Gordon, Joshua A; Zanes, Robert C; Zuskov, Andrey; Vinciguerra, John D; Bloebaum, Roy D; Soslowsky, Louis J

    2017-03-01

    Current techniques in rotator cuff repair often lack structural integrity. P 2 porous titanium-coated constructs (DJO Surgical, Austin, TX, USA) promote osseointegration and soft tissue ingrowth. This study examined the ability of this material to improve the structural integrity of supraspinatus tendon repair in a rat model. We hypothesized that P 2 implants placed at the tendon-to-bone interface would improve mechanical and histologic measures of supraspinatus healing. Forty rats underwent supraspinatus repairs with P 2 implants in 1 shoulder and standard repair in the other. Rats were humanely killed at time 0 (n = 3), 2 weeks (n = 8), 4 weeks (n = 15), and 12 weeks (n = 14). Tendon-to-bone composite specimens were harvested and evaluated mechanically and histologically. Tendon cross-sectional area was decreased in the P 2 implant group at 4 weeks, percentage of relaxation was increased at 2 weeks, elastic modulus was increased at 4 weeks, and maximum load and maximum stress were both increased at 2 and 4 weeks. Histologic analysis revealed no foreign body reactions within or around the P 2 implant, and healthy viable bone was visible within the P 2 implant. The results support our hypothesis, specifically in early healing, in this randomized controlled animal study. These data support the use of P 2 porous titanium implants to improve tendon-to-bone healing. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Augmented Repair of an Achilles Tendon Rupture Using the Flexor Digitorum Lateralis Tendon in a Toy Poodle.

    PubMed

    Katayama, Masaaki

    2016-11-01

    To report appositional augmentation of Achilles tendon rupture in a toy breed dog with an intact flexor digitorum lateralis (FDL) muscle tendon. Clinical case report. Two-year-old spayed female Toy Poodle with Achilles tendon rupture. The Achilles tendon was accidentally ruptured by hair clippers during grooming. The dog demonstrated a plantigrade stance without digital flexion of the right hind limb. The ruptured gastrocnemius and superficial digital flexor tendons were sutured to their respective cut ends using a simple locking loop pattern under a surgical microscope. The repair site was appositionally augmented by the caudally retracted intact FDL. An aluminum splint was applied on the plantar aspect to immobilize the tarsal joint for the first 2 weeks, after which a soft bandage was applied for another 2 weeks. At the 7 month follow-up no lameness was detected during walking and no complications associated with decreased FDL function such as digital contracture were observed. The range of motion of the tarsal joint had improved and could be flexed to ∼60° and extended fully. Use of the FDL is feasible for augmenting Achilles tendon repair in toy breed dogs. © Copyright 2016 by The American College of Veterinary Surgeons.

  4. Platelet-rich plasma for rotator cuff repair.

    PubMed

    Barber, F Alan

    2013-12-01

    Rotator cuff tears are a common cause of shoulder pain and disability. Because they combine both traumatic and degenerative elements, the surgical repair can be challenging. Even after surgical intervention, tendon residual defects or "retears" often develop. Risk factors for tendon "retears" include patient age, number of tendons involved, tear size, and smoking. Platelet-rich plasma (PRP) is a supraphysiological concentration of platelets, which may be able to positively augment rotator cuff tendon healing. Not all PRPs are the same and those containing higher leukocyte levels may be detrimental to tendon healing. Thrombin activation triggers an immediate release of growth factors from the PRP and may actually inhibit some parts of the healing response. As yet, the clinical data does not conclusively prove a benefit from PRP, but discernment is required in evaluating the published results. As different PRPs may act differently and the results may be dose dependent requiring more PRP to achieve a beneficial threshold. How success is measured (clinical outcomes vs. intact cuff tendons) and how long the patients are followed are also critical items. Currently, the PRP fibrin matrix version holds the greatest promise for improving clinical success after rotator cuff tendon repair.

  5. Tendon Tissue Engineering: Progress, Challenges, and Translation to the Clinic

    PubMed Central

    Shearn, Jason T.; Kinneberg, Kirsten R.C.; Dyment, Nathaniel A.; Galloway, Marc T.; Kenter, Keith; Wylie, Christopher; Butler, David L.

    2013-01-01

    The tissue engineering field has made great strides in understanding how different aspects of tissue engineered constructs (TECs) and the culture process affect final tendon repair. However, there remain significant challenges in developing strategies that will lead to a clinically effective and commercially successful product. In an effort to increase repair quality, a better understanding of normal development, and how it differs from adult tendon healing, may provide strategies to improve tissue engineering. As tendon tissue engineering continues to improve, the field needs to employ more clinically relevant models of tendon injury such as degenerative tendons. We need to translate successes to larger animal models to begin exploring the clinical implications of our treatments. By advancing the models used to validate our TECs, we can help convince our toughest customer, the surgeon, that our products will be clinically efficacious. As we address these challenges in musculoskeletal tissue engineering, the field still needs to address the commercialization of products developed in the laboratory. TEC commercialization faces numerous challenges because each injury and patient is unique. This review aims to provide tissue engineers with a summary of important issues related to engineering tendon repairs and potential strategies for producing clinically successful products. PMID:21625053

  6. Stem cell technology for tendon regeneration: current status, challenges, and future research directions

    PubMed Central

    Lui, Pauline Po Yee

    2015-01-01

    Tendon injuries are a common cause of physical disability. They present a clinical challenge to orthopedic surgeons because injured tendons respond poorly to current treatments without tissue regeneration and the time required for rehabilitation is long. New treatment options are required. Stem cell-based therapies offer great potential to promote tendon regeneration due to their high proliferative, synthetic, and immunomodulatory activities as well as their potential to differentiate to the target cell types and undergo genetic modification. In this review, I first recapped the challenges of tendon repair by reviewing the anatomy of tendon. Next, I discussed the advantages and limitations of using different types of stem cells compared to terminally differentiated cells for tendon tissue engineering. The safety and efficacy of application of stem cells and their modified counterparts for tendon tissue engineering were then summarized after a systematic literature search in PubMed. The challenges and future research directions to enhance, optimize, and standardize stem cell-based therapies for augmenting tendon repair were then discussed. PMID:26715856

  7. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model.

    PubMed

    Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul

    2015-11-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.

  8. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model

    PubMed Central

    Park, Gi-Young; Lee, Sang Chul

    2015-01-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340

  9. Shoulder abduction diminishes self-reinforcement in transosseous-equivalent rotator cuff repair in both knotted and knotless techniques.

    PubMed

    Smith, Geoffrey C S; Lam, Patrick H

    2018-06-20

    The self-reinforcement mechanism after double row suturebridge rotator cuff repair generates increasing compressive forces at the tendon footprint with increasing tendon load. Passive range of motion is usually allowed after rotator cuff repair. The mechanism of self-reinforcement could be adversely affected by shoulder abduction. Rotator cuff tears were created ex vivo in nine pairs of ovine shoulders. Two different repair techniques were used. One group was repaired using a double row 'suturebridge' construct with tied horizontal medial row mattress sutures (Knotted repair group). The other group was repaired identically except that medial row knots were not tied (Knotless repair group). Footprint compression was measured at varying amounts of abduction and under tendon loads of 0, 10, 20, 30, 40, 50 and 60N. The rate of increase of contact pressure (degree of self-reinforcement) was calculated for each abduction angle. Abduction diminishes footprint contact pressure in both knotted and knotless double row suturebridge constructs. Progressive abduction from 0 to 40 abduction in the knotless group and 0-30 in the knotted group results in a decrease in self-reinforcement. Abduction beyond this does not cause a further decrease in self-reinforcement. There was no difference in the rate of increase of footprint contact pressure at each angle of abduction when comparing the knotted and knotless groups. In the post-operative period, high tendon load combined with minimal abduction would be expected to generate the greatest amount of footprint compression which may improve tendon healing. Therefore, to maximize footprint compression the use of abduction pillows should be avoided while early isometric strengthening should be used.

  10. Biomechanical evaluation of a novel suturing scheme for grafting load-bearing collagen scaffolds for rotator cuff repair

    PubMed Central

    Islam, Anowarul; Bohl, Michael S.; Tsai, Andrew G; Younesi, Mousa; Gillespie, Robert; Akkus, Ozan

    2015-01-01

    Background Currently, there are no well-established suture protocols to attach fully load-bearing scaffolds which span tendon defects between bone and muscle for repair of critical sized tendon tears. Methods to attach load-bearing tissue repair scaffolds could enable functional repair of tendon injuries. Methods Sixteen rabbit shoulders were dissected (New Zealand white rabbits, 1 yr. old, female) to isolate the humeral-infraspinatus muscle complex. A unique suture technique was developed to allow for a 5 mm segmental defect in infraspinatus tendon to be replaced with a mechanically strong bioscaffold woven from pure collagen threads. The suturing pattern resulted in a fully load-bearing scaffold. The tensile stiffness and strength of scaffold repair was compared with intact infraspinatus and regular direct repair. Findings The failure load and displacement at failure of the scaffold repair group were 59.9 N (Standard Deviation, SD = 10.7) and 10.3 mm (SD = 2.9), respectively and matched those obtained by direct repair group which were 57.5 N (SD = 15.3) and 8.6 mm (SD = 1.5), (p > 0.05). Failure load, displacement at failure and stiffness of both of the repair groups were half of the intact infraspinatus shoulder group. Interpretation With the developed suture technique, scaffolds repair showed similar failure load, displacement at failure and stiffness to the direct repair. This novel suturing pattern and the mechanical robustness of the scaffold at time zero indicates that the proposed model is mechanically viable for future in vivo studies which has a higher potential to translate into clinical uses. PMID:26009492

  11. Does immobilization after arthroscopic rotator cuff repair increase tendon healing? A systematic review and meta-analysis.

    PubMed

    Shen, Chong; Tang, Zhi-Hong; Hu, Jun-Zu; Zou, Guo-Yao; Xiao, Rong-Chi; Yan, Dong-Xue

    2014-09-01

    To determine whether immobilization after arthroscopic rotator cuff repair improved tendon healing compared with early passive motion. A systematic electronic literature search was conducted to identify randomized controlled trials (RCTs) comparing early passive motion with immobilization after arthroscopic rotator cuff repair. The primary outcome assessed was tendon healing in the repaired cuff. Secondary outcome measures were range of motion (ROM) and American Shoulder and Elbow Surgeons (ASES) shoulder scale, Simple Shoulder Test (SST), Constant, and visual analog scale (VAS) for pain scores. Pooled analyses were performed using a random effects model to obtain summary estimates of treatment effect with 95% confidence intervals. Heterogeneity among included studies was quantified. Three RCTs examining 265 patients were included. Meta-analysis revealed no significant difference in tendon healing in the repaired cuff between the early-motion and immobilization groups. A significant difference in external rotation at 6 months postoperatively favored early motion over immobilization, but no significant difference was observed at 1 year postoperatively. In one study, Constant scores were slightly higher in the early-motion group than in the immobilization group. Two studies found no significant difference in ASES, SST, or VAS score between groups. We found no evidence that immobilization after arthroscopic rotator cuff repair was superior to early-motion rehabilitation in terms of tendon healing or clinical outcome. Patients in the early-motion group may recover ROM more rapidly. Level II; systematic review of levels I and II studies.

  12. The use of a cognitive task analysis-based multimedia program to teach surgical decision making in flexor tendon repair.

    PubMed

    Luker, Kali R; Sullivan, Maura E; Peyre, Sarah E; Sherman, Randy; Grunwald, Tiffany

    2008-01-01

    The aim of this study was to compare the surgical knowledge of residents before and after receiving a cognitive task analysis-based multimedia teaching module. Ten plastic surgery residents were evaluated performing flexor tendon repair on 3 occasions. Traditional learning occurred between the first and second trial and served as the control. A teaching module was introduced as an intervention between the second and third trial using cognitive task analysis to illustrate decision-making skills. All residents showed improvement in their decision-making ability when performing flexor tendon repair after each surgical procedure. The group improved through traditional methods as well as exposure to our talk-aloud protocol (P > .01). After being trained using the cognitive task analysis curriculum the group displayed a statistically significant knowledge expansion (P < .01). Residents receiving cognitive task analysis-based multimedia surgical curriculum instruction achieved greater command of problem solving and are better equipped to make correct decisions in flexor tendon repair.

  13. A novel method for reducing gap formation in tendon repair.

    PubMed

    Dean, Ryan; Sethi, Paul

    2018-03-01

    This study investigates gap formation in tendon repair using a novel tensioning method. The novel stitch will demonstrate less gap formation than the other suture configurations tested. Porcine tendons stitched with classic Krackow stitch configurations were compared to a Krackow stitch modified with a proximal Tension-Assist Loop. Each group was cyclically loaded followed by analysis of the tendon-suture construct for gap formation. The Tension-Assist Loop group produced significantly less gap formation than each of the other stitch groups. Decreasing early gap formation may be beneficial in allowing early rehabilitation and range of motion.

  14. The improved oval forceps suture-guiding method for minimally invasive Achilles tendon repair.

    PubMed

    Liu, Yang; Lin, Lixiang; Lin, Chuanlu; Weng, Qihao; Hong, Jianjun

    2018-06-01

    To discuss the effect and advantage of the improved oval forceps suture-guiding method combined with anchor nail in the treatment of acute Achilles tendon rupture. A retrospective research was performed on 35 cases of acute Achilles tendon rupture treated with the improved oval forceps suture-guiding method from January 2013 to October 2016. Instead of the Achillon device, we perform the Achillon technique with the use of simple oval forceps, combined with absorbable anchor nail, percutaneously to repair the acute Achilles tendon rupture. All patients were followed up for at least 12 months (range, 12-19 months), and all the patients underwent successful repair of their acute Achilles tendon rupture using the improved oval forceps suture-guiding method without any major intra- or postoperative complications. All the patients returned to work with pre-injury levels of activity at a mean of 12.51 ± 0.76 weeks. Mean AOFAS ankle-hindfoot scores improved from 63.95 (range, 51-78) preoperatively to 98.59 (range, 91-100) at last follow-up. This was statistically significant difference (P < 0.001). Mean Achilles Tendon Total Rupture Score (ATRS) at final follow-up was 94.87 (range, 90-100). The improved oval forceps suture-guiding method could make the advantage of minimally invasive repair with less complications, reduced surgical time and similar functional outcomes compared with the traditional open surgery. In addition, our new technique could save the cost of surgery with the compare of the Achillon device. At the same time for the cases which the remote broken tendon ends were within 2 cm from the calcaneal nodules, because of the less tendon tissue was left in the remote side, traditional percutaneous methods are incapable to ensure the reconstruction strength. By using the anchor nail, the improved technique has better repair capacity and expands the operation indication of oval forceps method. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Conservative, minimally invasive and open surgical repair for management of acute ruptures of the Achilles tendon: a clinical and functional retrospective study.

    PubMed

    Maffulli, Gayle; Buono, Angelo Del; Richards, Paula; Oliva, Francesco; Maffulli, Nicola

    2017-01-01

    At present, it is unclear which is the best management for Achilles tendon rupture. We assess the clinical, functional and imaging outcomes of active patients undergoing 3 different types of management for acute subcutaneous rupture of the Achilles tendon, including conservative cast immobilization, traditional open surgery and percutaneous repair. 26 active patients were managed for a rupture of the Achilles Tendon from January 2007 to March 2008. Anthropometric measurements, Functional assessment, Isometric strength, Ultrasonographic assessment, Patient satisfaction, Working life, Physical activity, Functional score and Complications were recorded retrospectively. All 23 (21 men, 2 women) patients were reviewed at a minimum follow-up of 24 months (average 25.7, range 24 to 32 months, SD: 6.3) from the index injury. Thermann scores and patient satisfaction were significantly higher following surgery than conservative management with no significance between open and minimally invasive operated patients. Sensitive disturbances occur in up to 12% of open repairs and 1.8% of patients managed nonsurgically. Clinical and functional outcomes following surgical repair, percutaneous and open, of the Achilles tendon are significantly improved than following conservative management. Level III.

  16. Reconstruction of the extensor mechanism with fresh-frozen tendon allograft in total knee arthroplasty.

    PubMed

    Llombart Blanco, Rafael; Valentí, Andrés; Díaz de Rada, Pablo; Mora, Gonzalo; Valentí, Juan R

    2014-11-01

    Patellar tendon rupture after total knee replacement is a rare and highly limiting injury with multifactorial aetiology. Many reconstruction techniques have been described with not very predictable results. The use of allografts has been accepted as a suitable solution. A series of seven patients with patellar tendon rupture treated with fresh-frozen tendon allograft reconstruction after knee arthroplasty is presented. Median follow-up is 25 months (20-31). Functional assessment improved, and the knee society score and knee functional score improved from 26 and 16 to 82 and 55, respectively. Median extension lag was 5° (0°-20°), with a median range of motion of 95° (70-100). Radiological study showed a rise of the patella of 22.26 mm. The use of fresh-frozen allografts as a solution to patellar tendon ruptures after knee arthroplasty seems to provide acceptable results. Increased patellar height does not seem to affect functionality. Case series, Level IV.

  17. Vibration-evoked reciprocal inhibition between human wrist muscles.

    PubMed

    Cody, F W; Plant, T

    1989-01-01

    Reciprocal inhibition of the voluntarily contracting wrist extensor (extensor carpi radialis, ECR) evoked by proprioceptive afferent input from the flexor (flexor carpi radialis, FCR), was studied in healthy human subjects. Vibration of the FCR tendon was used to elicit Ia-dominated afferent discharge whilst inhibition of ECR was assessed as the reduction in asynchronous, on-going EMG. A small early phase of inhibition (I1) was evident in 25% of trials. The latency (ca. 25 ms) of this component suggested that it was mediated by an Ia oligosynaptic. possibly 'classical' disynaptic, inhibitory pathway. A later and apparently separate phase of reduced activity (I2, ca. 40 ms) was, however, far more consistently observed (96% of trials) and of greater magnitude. The I2 component was usually followed, some 20 ms later, by a phase of elevated activity (E1, 72% trials). Reductions in simultaneously recorded net extensor torque commenced at about 60 ms following the onset of flexor tendon vibration, i.e. some 20 ms after the main I2 EMG component. These mechanical responses must have almost exclusively resulted from reciprocal inhibition of extensor EMG since vibration of the relaxed FCR evoked minimal excitatory flexor activity. The reflex pattern, in any individual subject, was relatively unaffected by altering the duration of the vibration train between one and nineteen cycles (125 Hz). This suggests that the entire response complex resulted largely from the initial afferent volley. The sizes of both the I1 and I2 reductions in ECR activity increased with increasing voluntary extensor contraction so that their depths remained constant proportions of background EMG. Very similar results were obtained when reciprocal inhibition of FCR was produced by vibration of the belly of ECR. Thus, reciprocal inhibition between wrist muscles is mainly expressed as a rather stereotyped, short duration reduction in EMG whose depth is determined by the pre-existing level of motor activity. Some functional implications of this form of reflex behaviour are discussed.

  18. Effects of plasma rich in growth factors (PRGF) on biomechanical properties of Achilles tendon repair.

    PubMed

    López-Nájera, Diego; Rubio-Zaragoza, Mónica; Sopena-Juncosa, Joaquín J; Alentorn-Geli, Eduard; Cugat-Bertomeu, Ramón; Fernández-Sarmiento, J Andrés; Domínguez-Pérez, Juan M; García-Balletbó, Montserrat; Primo-Capella, Víctor J; Carrillo-Poveda, José M

    2016-12-01

    To assess the biomechanical effects of intra-tendinous injections of PRGF on the healing Achilles tendon after repair in a sheep model. Thirty sheep were randomly assigned into one of the six groups depending on the type of treatment received (PRGF or placebo) and survival time (2, 4 and 8 weeks). The Achilles tendon injury was repaired by suturing the tendinous edges employing a three-loop pulley pattern. A trans-articular external fixation system was then used for immobilization. The PRGF or placebo was administered on a weekly basis completing a maximum of three infiltrations. The force, section and tension values were compared between the operated and healthy Achilles tendons across all groups. The PRGF-treated tendons had higher force at 8 weeks compared with the placebo group (p = 0.007). Between 2 and 4 weeks, a significant increase in force in both the PRGF-treated tendon (p = 0.0027) and placebo group (p = 0.0095) occurred. No significant differences were found for section ratio between PRGF-treated tendons and the placebo group for any of the time periods evaluated. At 2 weeks, PRGF-treated tendons had higher tension ratio compared with placebo group tendons (p = 0.0143). Both PRGF and placebo treatments significantly improved the force (p < 0.001 and p = 0.0095, respectively) and tension (p = 0.009 and p = 0.0039, respectively) ratios at 8 weeks compared with 2 weeks. The application of PRGF increases Achilles tendon repair strength at 8 weeks compared with the use of placebo. The use of PRGF does not modify section and tension ratios compared with placebo at 8 weeks. The tension ratio progressively increases between 2 and 8 weeks compared with the placebo.

  19. PT-12, a putative ras-activated proliferation-dependent gene, is expressed in patellar tendon and not in anterior cruciate ligament.

    PubMed

    Goomer, R S; Maris, T; Ostrander, R; Amiel, D

    1999-09-01

    We describe a gene (PT-12) that is expressed in the patellar tendon and not in the anterior cruciate ligament. We used a recently developed polymerase chain reaction-based subtractive cDNA analysis to discover genes that are overexpressed in the patellar tendon but not expressed in the anterior cruciate ligament; the long-term objective was to find genes that are central to the self-repair of the patellar tendon, in contrast with the inability of the anterior cruciate ligament to launch a repair response following injury. PT-12 is a homologue of human S2 or mouse LLRep3 ribosomal genes, which are known to be overexpressed in highly proliferating cells. This study opens a new vista to the development of techniques and reagents to study the differences between two periarticular tissues (i.e., the patellar tendon and anterior cruciate ligament) that differ primarily in their ability to self-repair.

  20. Scaffolds for Tendon and Ligament Repair and Regeneration

    PubMed Central

    Ratcliffe, Anthony; Butler, David L; Dyment, Nathaniel A; Cagle, Paul J; Proctor, Christopher S; Ratcliffe, Seena S; Flatow, Evan L

    2015-01-01

    Enhanced tendon and ligament repair would have a major impact on orthopaedic surgery outcomes, resulting in reduced repair failures and repeat surgeries, more rapid return to function, and reduced health care costs. Scaffolds have been used for mechanical and biologic reinforcement of repair and regeneration with mixed results. This review summarizes efforts made using biologic and synthetic scaffolds using rotator cuff and ACL as examples of clinical applications, discusses recent advances that have shown promising clinical outcomes, and provides insight into future therapy. PMID:25650098

  1. Glucocorticoids induce specific ion-channel-mediated toxicity in human rotator cuff tendon: a mechanism underpinning the ultimately deleterious effect of steroid injection in tendinopathy?

    PubMed

    Dean, Benjamin John Floyd; Franklin, Sarah Louise; Murphy, Richard J; Javaid, Muhammad K; Carr, Andrew Jonathan

    2014-12-01

    Glucocorticoid injection (GCI) and surgical rotator cuff repair are two widely used treatments for rotator cuff tendinopathy. Little is known about the way in which medical and surgical treatments affect the human rotator cuff tendon in vivo. We assessed the histological and immunohistochemical effects of these common treatments on the rotator cuff tendon. Controlled laboratory study. Supraspinatus tendon biopsies were taken before and after treatment from 12 patients undergoing GCI and 8 patients undergoing surgical rotator cuff repair. All patients were symptomatic and none of the patients undergoing local GCI had full thickness tears of the rotator cuff. The tendon tissue was then analysed using histological techniques and immunohistochemistry. There was a significant increase in nuclei count and vascularity after rotator cuff repair and not after GCI (both p=0.008). Hypoxia inducible factor 1α (HIF-1α) and cell proliferation were only increased after rotator cuff repair (both p=0.03) and not GCI. The ionotropic N-methyl-d-aspartate receptor 1 (NMDAR1) glutamate receptor was only increased after GCI and not rotator cuff repair (p=0.016). An increase in glutamate was seen in both groups following treatment (both p=0.04), while an increase in the receptor metabotropic glutamate receptor 7 (mGluR7) was only seen after rotator cuff repair (p=0.016). The increases in cell proliferation, vascularity and HIF-1α after surgical rotator cuff repair appear consistent with a proliferative healing response, and these features are not seen after GCI. The increase in the glutamate receptor NMDAR1 after GCI raises concerns about the potential excitotoxic tendon damage that may result from this common treatment. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. The use of a magnesium-based bone adhesive for flexor tendon-to-bone healing

    PubMed Central

    Stavros, Thomopoulos; Emmanouil, Zampiakis; Rosalina, Das; Hyun-Min, Kim; J., Silva, Matthew; Necat, Havlioglu; H., Gelberman, Richard

    2010-01-01

    Purpose Our previous studies in a canine animal model demonstrated that the flexor tendon-to-bone insertion site has a poor capacity to heal. Magnesium based adhesives have the potential to improve tendon-to-bone healing. Therefore, we hypothesized that magnesium based bone adhesive (MBA) will improve the tendon-to-bone biomechanical properties initially and in the early period after repair. Methods Flexor digitorum profundus tendons were injured and repaired into bone tunnels in the distal phalanges of dogs. The bone tunnels were either filled with MBA prior to completing the repair or left empty (CTL). Histologic appearance, tensile properties, range of motion, and bone density were examined at time zero and 21 days after the repair. Results There was no histologic evidence of acute inflammation. There appeared to be more mast cells in the MBA group than in the CTL group. Chronic inflammatory infiltrate and fibrosis was slightly higher in the MBA group compared to the CTL group. Tensile properties at time zero were significantly higher in the MBA group compared to the CTL group. However, tensile properties were significantly lower in the MBA group compared to the CTL group at 21 days. Range of motion and bone density were significantly lower in the MBA and CTL groups compared to normal (i.e., uninjured) at 21 days; no differences were seen when comparing MBA to CTL. Conclusions We found that the initial biomechanical properties of flexor tendon-to-bone repairs can be improved with MBA. However, MBA use in vivo led to a decrease in the biomechanical properties of the repair. There was no effect of MBA on bone density or range of motion in the early period after repair. Our histologic analysis suggests that the poor healing in the MBA group may have been due to an allergic response or to increased chronic inflammation due to the foreign material. PMID:19643291

  3. Outcomes and complications of triceps tendon repair following acute rupture in American military personnel.

    PubMed

    Balazs, George C; Brelin, Alaina M; Dworak, Theodora C; Brooks, Daniel I; Mauntel, Timothy C; Tintle, Scott M; Dickens, Jonathan F

    2016-10-01

    Triceps tendon ruptures are uncommon injuries primarily occurring in young, active males or elderly individuals with various systemic diseases. Relatively little is known about the epidemiology of this injury, or the results of surgical management in high-demand populations. The purpose of this study was to define the incidence and outcomes of surgical treatment in active duty American military personnel. The Military Data Repository (MDR) was queried for all active duty military personnel undergoing surgical repair or reconstruction of a triceps tendon rupture between January 2012 and December 2014. The electronic health records of all patients with at least 12 months clinical follow-up were searched for demographic information, injury details, preoperative imaging findings, post-operative complications, and ability to return to duty following surgical repair. Incidence was calculated based on total active duty population in the MDR over the study period. Risk factors for postoperative complication and inability to return to duty following surgical repair were assessed using univariate analyses. A total of 54 acute triceps tendon ruptures were identified in the search, of which 48 had at least 12 months follow-up and complete post-operative records. The incidence of acute triceps tendon rupture was 1.1 per 100,000 person-years. Twelve patients experienced post-operative complications, six of which were traumatic re-ruptures within four months of the index surgery. No patient had a post-operative infection or atraumatic repair failure. 94% of patients were able to return to active military service following surgical repair. Enlisted rank was a significant risk factor for a post-operative complication, but no factor predicted inability to return to active duty service. Surgical repair of acute triceps tendon ruptures reliably restores strength and function even in high-demand individuals. In our population, traumatic rerupture was the most common complication. Published by Elsevier Ltd.

  4. Histological study of the influence of plasma rich in growth factors (PRGF) on the healing of divided Achilles tendons in sheep.

    PubMed

    Fernández-Sarmiento, J Andrés; Domínguez, Juan M; Granados, María M; Morgaz, Juan; Navarrete, Rocío; Carrillo, José M; Gómez-Villamandos, Rafael J; Muñoz-Rascón, Pilar; Martín de Las Mulas, Juana; Millán, Yolanda; García-Balletbó, Montserrat; Cugat, Ramón

    2013-02-06

    The use of plasma rich in growth factors (PRGF) has been proposed to improve the healing of Achilles tendon injuries, but there is debate about the effectiveness of this therapy. The objective of the present study was to evaluate the histological effects of PRGF, which is a type of leukocyte-poor platelet-rich plasma, on tendon healing. The Achilles tendons of twenty-eight sheep were divided surgically. The animals were randomly divided into four groups of seven animals each. The repaired tendons in two groups received an infiltration of PRGF intraoperatively and every week for the following three weeks under ultrasound guidance. The tendons in the other two groups received injections with saline solution. The animals in one PRGF group and one saline solution group were killed at four weeks, and the animals in the remaining two groups were killed at eight weeks. The Achilles tendons were examined histologically, and the morphometry of fibroblast nuclei was calculated. The fibroblast nuclei of the PRGF-treated tendons were more elongated and more parallel to the tendon axis than the fibroblast nuclei of the tendons in the saline solution group at eight weeks. PRGF-treated tendons showed more packed and better oriented collagen bundles at both four and eight weeks. In addition to increased maturation of the collagen structure, fibroblast density was significantly lower in PRGF-infiltrated tendons. PRGF-treated tendons exhibited faster vascular regression than tendons in the control groups, as demonstrated by a lower vascular density at eight weeks. PRGF was associated with histological changes consistent with an accelerated early healing process in repaired Achilles tendons in sheep after experimental surgical disruption. PRGF-treated tendons showed improvements in the morphometric features of fibroblast nuclei, suggesting a more advanced stage of healing. At eight weeks, histological examination revealed more mature organization of collagen bundles, lower vascular densities, and decreased fibroblast densities in PRGF-treated tendons than in tendons infiltrated with saline solution. These findings were consistent with a more advanced stage of the healing process. Based on the findings in this animal model, PRGF infiltration may improve the early healing process of surgically repaired Achilles tendons.

  5. Management of an unusual extreme extension contracture of the wrist: role of a custom-designed exercise program in achieving a good range of movement and prevention of recontraction.

    PubMed

    Saraiya, Hemant

    2003-01-01

    An extreme extension contracture of wrist with dorsal contracture of fingers 15 years after burn injury is described. Shortening of extensor tendons, secondary lengthening of flexor tendons, contracted wrist joint capsule, unusual dislocation of carpals, dorsal dislocation of metacarpophalangeal joints of fingers, and provision of sufficient amount of good-quality skin were some of the issues that had to be addressed in treatment. The contracture was released, the carpals and metacarpophalangeal joint dislocations were corrected and fixed with K wires, and the resulting defect was covered with a sheet split-thickness skin graft. An exercise program was designed that consisted of isotonic, isokinetic, and isometric resistance exercises and passive, active, and active-assistive range of motion exercises. These exercises were pursued with the intention of increasing dynamic strength, endurance, and overall functional recovery of the flexor muscles by exploiting the immature nature of early scar tissue. The resultant enhanced flexor muscle power from exercises along with the dynamic splint helped in lengthening of extensor tendons, wrist joint capsule, and split-thickness skin graft. It also helped in resisting the recontracting tendency, with further recovery of good range of wrist and fingers movements, obviating the need of tendon-lengthening surgery and flap coverage. One and half years of follow up didn't show any sign of recontracture, and the patient was able to perform his routine activities. Postburn wrist contractures of such magnitude have been seldom described. Emphasis is put on simple contracture release and a postoperative exercise program.

  6. Disruption of quadriceps tendon after total knee arthroplasty: Case report of four cases.

    PubMed

    Soong, J W; Silva, A N; Andrew, Tan Hc

    2017-01-01

    Quadriceps tendon rupture after total knee arthroplasty (TKA) is a rare but dire complication. It is associated with adverse outcomes and morbidities. Studies on such complications are scarce in the literature. In this study, we share our experience in the management of four patients who sustained quadriceps tendon rupture in the early postoperative period. Efforts should be focused on prevention. Meticulous surgical techniques during the medial parapatellar approach to preserve the integrity of quadriceps can reduce the risk of rupture. The importance of prompt diagnosis is emphasized as delayed treatment may lead to poor outcomes. However, making a diagnosis can be challenging, as worsening of the quadriceps strength after TKA is expected because of the surgical approach that violates the quadriceps muscle. In an event of postoperative trauma with resultant extensor weakness, an ultrasound evaluation to exclude a quadriceps tendon rupture should be promptly performed after a fracture is excluded.

  7. The prevalence of the extensor digiti minimi tendon of the hand and its variants in humans: a systematic review and meta-analysis.

    PubMed

    Yammine, Kaissar

    2015-01-01

    The extensor digiti minimi (EDM) is frequently used in the case of an abduction deformity of the little finger. It is also considered as a main resource for tendon transfer. However, it shows many variations in the human hand, which include splitting into two or more slips and sending a slip to the fourth finger, named the extensor digiti minimi et quarti (EDMQ). The aim of this systematic review is to perform an evidence synthesis on the prevalence of the EDM and its variants. Twenty-six cadaveric studies met the inclusion criteria with a total of 2247 hands. Meta-analysis results yielded an overall pooled prevalence estimate (PPE) of the EDM of 99.7% and PPEs of 11.5, 77.6, 7 and 0.6% for the single-, double-, triple- and quadruple-slip EDM, respectively. For the single-slip EDM, the frequencies were such that Indians > Middle Eastern > Europeans > Japanese > North Americans. For the double-slip EDM, the frequencies were such that Japanese > North Americans = Europeans > Middle Eastern > Indians. No significance was found with regard to hand side. The true EDMQ prevalence was found to be at 7.3%, whereas its crude prevalence was 8%. This artilce offers reference values on the prevalence of the EDM and its variants, which are thought to be highly relevant to both anatomists and clinicians.

  8. Reconstruction of a ruptured patellar tendon using ipsilateral semitendinosus and gracilis tendons with preserved distal insertions: two case reports

    PubMed Central

    2013-01-01

    Background Acute patellar tendon ruptures with poor tissue quality. Ruptures that have been neglected are difficult to repair. Several surgical techniques for the repair of the patellar tendon have been reported, however, these techniques remain difficult because of contractures, adhesions, and atrophy of the quadriceps muscle after surgery. Case presentation We report the cases of 2 Japanese patients (Case 1: a 16-year-old male and Case 2: a 43-year-old male) with patellar tendon ruptures who were treated by reconstruction using semitendinosus-gracilis (STG) tendons with preserved distal insertions. Retaining the original insertion of the STG appears to preserve its viability and provide the revascularization necessary to accelerate healing. Both tendons were placed in front of the patella, in a figure-of-eight fashion, providing stability to the patella. Conclusion Both patients recovered near normal strength and stability of the patellar tendon as well as restoration of function after the operation. PMID:24010848

  9. Current Biomechanical Concepts for Rotator Cuff Repair

    PubMed Central

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  10. The biomechanical effects of polytetrafluoroethylene suture augmentations in lateral-row rotator cuff repairs in an ovine model.

    PubMed

    Beimers, Lijkele; Lam, Patrick H; Murrell, George A C

    2014-10-01

    This study investigated the biomechanical effects of expanded polytetrafluoroethylene (ePTFE) suture augmentation patches in rotator cuff repair constructs. The infraspinatus tendon in 24 cadaveric ovine shoulders was repaired using an inverted horizontal mattress suture with 2 knotless bone anchors (ArthroCare, Austin, TX, USA) in a lateral-row configuration. Four different repair groups (6 per group) were created: (1) standard repair using inverted horizontal mattress sutures, (2) repair with ePTFE suture augmentations on the bursal side of the tendon, (3) repair with ePTFE suture augmentations on the articular side, and, (4) repair with ePTFE suture augmentations on both sides of the tendon. Footprint contact pressure, stiffness, and the load to failure of the repair constructs were measured. Repairs with ePTFE suture augmentations on the bursal side exerted significantly more footprint contact pressure (0.40 ± 0.01 MPa) than those on the articular side (0.34 ± 0.02 MPa, P = .04) and those on both sides (0.33 ± 0.02 MPa, P = .01). At 15 degrees of abduction, ePTFE-augmented repairs on the bursal side had higher footprint contact pressure (0.26 ± 0.03 MPa) compared with standard repairs (0.15 ± 0.02 MPa, P = .01) and with ePTFE-augmented repairs on the articular side (0.18 ± 0.02 MPa, P = .03). The ePTFE-augmented repairs on the bursal side demonstrated significantly higher failure loads (178 ± 18 N) than standard repairs (120 ± 17 N, P = .04). Inverted horizontal mattress sutures augmented with ePTFE patches on the bursal side of the tendon enhanced footprint contact pressures and the ultimate load to failure of lateral-row rotator cuff repairs in an ovine model. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Delayed Exercise Promotes Remodeling in Sub-Rupture Fatigue Damaged Tendons

    PubMed Central

    Bell, R.; Boniello, M.R.; Gendron, N.R.; Flatow, E.L.; Andarawis-Puri, N.

    2015-01-01

    Tendinopathy is a common musculoskeletal injury whose treatment is limited by ineffective therapeutic interventions. Previously we have shown that tendons ineffectively repair early sub-rupture fatigue damage. In contrast, physiological exercise has been shown to promote remodeling of healthy tendons but its utility as a therapeutic to promote repair of fatigue damaged tendons remains unknown. Therefore, the objective of this study was to assess the utility of exercise initiated 1 and 14 days after onset of fatigue damage to promote structural repair in fatigue damaged tendons. We hypothesized that exercise initiated 14 days after fatigue loading would promote remodeling as indicated by a decrease in area of collagen matrix damage, increased procollagen I and decorin, while decreasing proteins indicative of tendinopathy. Rats engaged in 6-week exercise for 30 min/day or 60 min/day starting 1 or 14 days after fatigue loading. Initiating exercise 1-day after onset of fatigue injury led to exacerbation of matrix damage, particularly at the tendon insertion. Initiating exercise 14 days after onset of fatigue injury led to remodeling of damaged regions in the midsubstance and collagen synthesis at the insertion. Physiological exercise applied after the initial biological response to injury has dampened can potentially promote remodeling of damaged tendons. PMID:25732052

  12. Suture anchor tenodesis in repair of distal Achilles tendon injuries.

    PubMed

    Kiliçoğlu, Onder; Türker, Mehmet; Yildız, Fatih; Akalan, Ekin; Temelli, Yener

    2014-01-01

    Distal Achilles tendon avulsions are in the form of either bony and nonbony avulsion of Achilles tendon from its calcaneal insertion. Four patients with distal Achilles tendon avulsions or ruptures which were treated with tendon to bone repair using suture anchors are presented here. Operated leg was immobilized in above-knee cast for 4 weeks while the patient walked non-weight-bearing. Then, cast was changed to below knee, and full weight-bearing was allowed. Patients underwent gait analysis minimum at first postoperative year. Mean American Orthopedics Foot Ankle Society ankle/hindfoot score of patients at last visit was 88.75 (range 85-100), and Achilles tendon total rupture score was 77.75 (range 58-87). Mean passive dorsiflexion of injured ankles (14° ± 5°) was lower than uninjured ankles (23° ± 9°). All the kinematic parameters of gait analysis were comparable to the uninjured side. Maximum plantar flexion power of injured ankle was 1.40 W/kg, and this was significantly lower than the contralateral side value 2.38 W/kg; (P = 0.0143). There were no visually altered gait or problems in daily life. Suture anchor tenodesis technique of distal Achilles tendon avulsions was successful in achieving durable osteotendinous repairs.

  13. Aging Does Not Alter Tendon Mechanical Properties During Homeostasis, but does Impair Flexor Tendon Healing

    PubMed Central

    Ackerman, Jessica E.; Bah, Ibrahima; Jonason, Jennifer H.; Buckley, Mark R.; Loiselle, Alayna E.

    2017-01-01

    Aging is an important factor in disrupted homeostasis of many tissues. While an increased incidence of tendinopathy and tendon rupture are observed with aging, it is unclear whether this is due to progressive changes in tendon cell function and mechanics over time, or an impaired repair reaction from aged tendons in response to insult or injury. In the present study we examined changes in the mechanical properties of Flexor Digitorum Longus (FDL), Flexor Carpi Ulnaris (FCU), and tail fascicles in both male and female C57Bl/6 mice between 3-27 months of age to better understand the effects of sex and age on tendon homeostasis. No change in max load at failure was observed in any group over the course of aging, although there were significant decreases in toe and linear stiffness in female mice from 3-months to 15, and to 22-27-months. No changes in cell proliferation were observed with aging, although an observable decrease in cellularity occurred in 31-month old tendons. Given that aging did not dramatically alter tendon mechanical homeostasis we hypothesized that a disruption in tendon homeostasis, via acute injury would result in an impaired healing response. Significant decreases in max load, stiffness, and yield load were observed in repairs of 22-month old mice, relative to 4-month old mice. No changes in cell proliferation were observed between young and aged, however a dramatic loss of bridging collagen extracellular matrix was observed in aged repairs suggest that matrix production, but not cell proliferation leads to impaired tendon healing with aging. PMID:28419543

  14. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors.

    PubMed

    Barber, F Alan; Drew, Otis R

    2012-09-01

    To compare tendon-bone interface motion and cyclic loading in a single-row, triple-loaded anchor repair with a suture-tape, rip-stop, double-row rotator cuff repair. Using 18 human shoulders from 9 matched cadaveric pairs, we created 2 groups of rotator cuff repairs. Group 1 was a double-row, rip-stop, suture-tape construct. Group 2 was a single-row, triple-loaded construct. Before mechanical testing, the supraspinatus footprint was measured with calipers. A superiorly positioned digital camera optically measured the tendon footprint motion during 60° of humeral internal and external rotation. Specimens were secured at a fixed angle not exceeding 45° in reference to the load. After preloading, each sample was cycled between 10 N and 100 N for 200 cycles at 1 Hz, followed by destructive testing at 33 mm/s. A digital camera with tracking software measured the repair displacement at 100 and 200 cycles. Ultimate load and failure mode for each sample were recorded. The exposed anterior footprint border (6.5% ± 6%) and posterior footprint border (0.9% ± 1.7%) in group 1 were statistically less than the exposed anterior footprint border (30.3% ± 17%) and posterior footprint border (29.8% ± 14%) in group 2 (P = .003 and P < .001, respectively). The maximal internal rotation and external rotation tendon footprint displacements in group 1 (1.6 mm and 1.4 mm, respectively) were less than those in group 2 (both 3.6 mm) (P = .007 and P = .004, respectively). Mean displacement after 100 cycles for group 1 and group 2 was 2.0 mm and 3.2 mm, respectively, and at 200 cycles, mean displacement was 2.5 mm and 4.2 mm, respectively (P = .02). The mean ultimate failure load in group 1 (586 N) was greater than that in group 2 (393 N) (P = .02). The suture-tendon interface was the site of most construct failures. The suture-tape, rip-stop, double-row rotator cuff repair had greater footprint coverage, less rotational footprint displacement, and a greater mean ultimate failure load than the triple-loaded, single-row repair on mechanical testing. No double-row or single-row constructs showed 5 mm of displacement after the first 100 cycles. The most common failure mode for both constructs was suture tearing through the tendon. Differences in cuff fixation influence rotational tendon movement and may influence postoperative healing. Stronger repair constructs still fail at the suture-tendon interface. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Investigating tendon mineralisation in the avian hindlimb: a model for tendon ageing, injury and disease

    PubMed Central

    Agabalyan, Natacha A; Evans, Darrell J R; Stanley, Rachael L

    2013-01-01

    Mineralisation of the tendon tissue has been described in various models of injury, ageing and disease. Often resulting in painful and debilitating conditions, the processes underlying this mechanism are poorly understood. To elucidate the progression from healthy tendon to mineralised tendon, an appropriate model is required. In this study, we describe the spontaneous and non-pathological ossification and calcification of tendons of the hindlimb of the domestic chicken (Gallus gallus domesticus). The appearance of the ossified avian tendon has been described previously, although there have been no studies investigating the developmental processes and underlying mechanisms leading to the ossified avian tendon. The tissue and cells from three tendons – the ossifying extensor and flexor digitorum longus tendons and the non-ossifying Achilles tendon – were analysed for markers of ageing and mineralisation using histology, immunohistochemistry, cytochemistry and molecular analysis. Histologically, the adult tissue showed a loss of healthy tendon crimp morphology as well as markers of calcium deposits and mineralisation. The tissue showed a lowered expression of collagens inherent to the tendon extracellular matrix and presented proteins expressed by bone. The cells from the ossified tendons showed a chondrogenic and osteogenic phenotype as well as tenogenic phenotype and expressed the same markers of ossification and calcification as the tissue. A molecular analysis of the gene expression of the cells confirmed these results. Tendon ossification within the ossified avian tendon seems to be the result of an endochondral process driven by its cells, although the roles of the different cell populations have yet to be elucidated. Understanding the role of the tenocyte within this tissue and the process behind tendon ossification may help us prevent or treat ossification that occurs in injured, ageing or diseased tendon. PMID:23826786

  16. Evaluation of a New Knotless Suture Anchor Repair in Acute Achilles Tendon Ruptures: A Biomechanical Comparison of Three Techniques.

    PubMed

    Cottom, James M; Baker, Joseph S; Richardson, Phillip E; Maker, Jared M

    Acute ruptures of the Achilles tendon are a common injury, and debate has continued in published studies on how best to treat these injuries. Specifically, controversy exists regarding the surgical approaches for Achilles tendon repair when one considers percutaneous versus open repair. The present study investigated the biomechanical strength of 3 different techniques for Achilles tendon repair in a cadaveric model. A total of 36 specimens were divided into 3 groups, each of which received a different construct. The first group received a traditional Krackow suture repair, the second group was repaired using a jig-assisted percutaneous suture, and the third group received a repair using a jig-assisted percutaneous repair modified with suture anchors placed into the calcaneus. The specimens were tested with cyclical loading and to ultimate failure. Cyclical loading showed a trend toward a stronger repair with the use of suture anchors after 10 cycles (p = .295), 500 cycles (p = .120), and 1000 cycles (p = .040). The ultimate load to failure was greatest in the group repaired with the modified knotless technique using the suture anchors (p = .098). The results of the present study show a clear trend toward a stronger construct in Achilles repair using a knotless suture anchor technique, which might translate to a faster return to activity and be more resistant to an early and aggressive rehabilitation protocol. Further clinical studies are warranted to evaluate this technique in a patient population. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Stem Cell Applications in Tendon Disorders: A Clinical Perspective

    PubMed Central

    Young, Mark

    2012-01-01

    Tendon injuries are a common cause of morbidity and a significant health burden on society. Tendons are structural tissues connecting muscle to bone and are prone to tearing and tendinopathy, an overuse or degenerative condition that is characterized by failed healing and cellular depletion. Current treatments, for tendon tear are conservative, surgical repair or surgical scaffold reconstruction. Tendinopathy is treated by exercises, injection therapies, shock wave treatments or surgical tendon debridement. However, tendons usually heal with fibrosis and scar tissue, which has suboptimal tensile strength and is prone to reinjury, resulting in lifestyle changes with activity restriction. Preclinical studies show that cell therapies have the potential to regenerate rather than repair tendon tissue, a process termed tenogenesis. A number of different cell lines, with varying degrees of differentiation, have being evaluated including stem cells, tendon derived cells and dermal fibroblasts. Even though cellular therapies offer some potential in treating tendon disorders, there have been few published clinical trials to determine the ideal cell source, the number of cells to administer, or the optimal bioscaffold for clinical use. PMID:22448174

  18. Extracorporeal shock waves promote healing of collagenase-induced Achilles tendinitis and increase TGF-beta1 and IGF-I expression.

    PubMed

    Chen, Yeung-Jen; Wang, Ching-Jen; Yang, Kuender D; Kuo, Yur-Ren; Huang, Hui-Chen; Huang, Yu-Ting; Sun, Yi-Chih; Wang, Feng-Sheng

    2004-07-01

    Extracorporeal shock waves (ESW) have recently been used in resolving tendinitis. However, mechanisms by which ESW promote tendon repair is not fully understood. In this study, we reported that an optimal ESW treatment promoted healing of Achilles tendintis by inducing TGF-beta1 and IGF-I. Rats with the collagenease-induced Achilles tendinitis were given a single ESW treatment (0.16 mJ/mm(2) energy flux density) with 0, 200, 500 and 1000 impulses. Achilles tendons were subjected to biomechanical (load to failure and stiffness), biochemical properties (DNA, glycosaminoglycan and hydroxyproline content) and histological assessment. ESW with 200 impulses restored biomechanical and biochemical characteristics of healing tendons 12 weeks after treatment. However, ESW treatments with 500 and 1000 impulses elicited inhibitory effects on tendinitis repair. Histological observation demonstrated that ESW treatment resolved edema, swelling, and inflammatory cell infiltration in injured tendons. Lesion site underwent intensive tenocyte proliferation, neovascularization and progressive tendon tissue regeneration. Tenocytes at the hypertrophied cellular tissue and newly developed tendon tissue expressed strong proliferating cell nuclear antigen (PCNA) after ESW treatment, suggesting that physical ESW could increase the mitogenic responses of tendons. Moreover, the proliferation of tenocytes adjunct to hypertrophied cell aggregate and newly formed tendon tissue coincided with intensive TGF-beta1 and IGF-I expression. Increasing TGF-beta1 expression was noted in the early stage of tendon repair, and elevated IGF-I expression was persisted throughout the healing period. Together, low-energy shock wave effectively promoted tendon healing. TGF-beta1 and IGF-I played important roles in mediating ESW-stimulated cell proliferation and tissue regeneration of tendon.

  19. Rotator cuff healing after continuous subacromial bupivacaine infusion: an in vivo rabbit study

    PubMed Central

    FRIEL, NICOLE A.; WANG, VINCENT M.; SLABAUGH, MARK A.; WANG, FANCHIA; CHUBINSKAYA, SUSAN; COLE, BRIAN J.

    2013-01-01

    Background The objective of this study was to evaluate the effects of continuous subacromial bupivacaine infusion on supraspinatus muscle and rotator cuff tendon healing via gross, biomechanical, and histologic analyses. Methods Thirty-three New Zealand White rabbits underwent unilateral supraspinatus transection and rotator cuff repair (RCR). Rabbits were assigned to 1 of 3 groups: (1)RCR only, (2)RCR with continuous saline infusion for 48 hours, or (3)RCR with continuous 0.25% bupivacaine with epinephrine (1:200,000) infusion for 48 hours. Rabbits were sacrificed at either 2 (for histologic assessment) or 8 weeks post-operatively (for biomechanical and histologic assessment). Results Tensile testing showed significantly higher load to failure in intact tendons compared to repaired tendons (p<0.01); however, no statistical differences were detected among RCR only, RCR Saline, and RCR Bupivacaine groups. Histologically, the enthesis of repaired tendons showed increased cellularity and disorganized collagen fibers compared to intact tendons, with no differences between treatment groups. Muscle histology demonstrated scattered degenerative muscle fibers at 2 weeks in both RCR Saline and RCR Bupivacaine, but no degeneration was noted at 8 weeks. Conclusions The healing supraspinatus tendons exposed to bupivacaine infusion showed similar histologic and biomechanical characteristics compared to untreated and saline infused RCR groups. Muscle histology showed fiber damage at 2 weeks for both the saline and bupivacaine treated groups, with no apparent disruption at 8 weeks, suggesting a recovery process. Therefore, subacromial bupivacaine infusion in this rabbit rotator cuff model does not appear to impair muscle or tendon following acute injury and repair. Level Of Evidence Basic science study PMID:22818894

  20. Effect of platelet-rich plasma on tendon-to-bone healing after rotator cuff repair in rats: an in vivo experimental study.

    PubMed

    Hapa, Onur; Cakıcı, Hüsamettin; Kükner, Aysel; Aygün, Hayati; Sarkalan, Nazlı; Baysal, Gökhan

    2012-01-01

    The purpose of this experimental study was to analyze the effects of local autologous platelet-rich plasma (PRP) injection on tendon-to-bone healing in a rotator cuff repair model in rats. Rotator cuff injury was created in 68 left shoulders of rats. PRP was obtained from the blood of an additional 15 rats. The 68 rats were divided into 4 groups with 17 rats in each group; PRP group (Week 2), control group (Week 2), PRP group (Week 4), and control group (Week 4). Platelet-rich plasma or saline was injected to the repair area intraoperatively. Rats were sacrificed 2 and 4 weeks after the surgery. Histological analysis using a semiquantitative scoring was performed on 7 rats per group. Tendon integrity and increases in vascularity and inflammatory cells and the degree of new bone formation were evaluated and compared between the groups. The remaining tendons (n=10) were mechanically tested. Degree of inflammation and vascularity were less in the study group at both time intervals (p<0.05). Tendon continuity was better in the study group at 2 weeks (p<0.05). Obvious new bone formation was detected in the control group at 4 weeks (p<0.05). Biomechanically, platelet-rich plasma-treated specimens were stronger at 2 weeks (p<0.05). Local autologous PRP injection may have beneficial effects on initial rotator cuff tendon-to-bone healing and enhance initial tendon-to-bone healing remodeling. This may represent a clinically important improvement in rotator cuff repair.

  1. Patient-Reported Outcomes and Return to Activity After Peroneus Brevis Repair.

    PubMed

    Steginsky, Brian; Riley, Aimee; Lucas, Douglas E; Philbin, Terrence M; Berlet, Gregory C

    2016-02-01

    There is limited data on functional outcomes after primary repair of partial peroneal tendon tears. Previous reports have been limited by small cohorts, duration of follow-up, and often included both tenodesis and primary repair. The purpose of this study was to report the functional outcomes and return to activity in the largest cohort to date with partial peroneal tendon tears treated with primary repair. A chart review identified all patients who underwent primary repair of the peroneus brevis tendon from 2008 to 2012. Demographic data, magnetic resonance imaging findings, and postoperative complications were reviewed. Patients were asked to complete a follow-up questionnaire, Foot and Ankle Ability Measure (FAAM), and Foot Function Index (FFI). There were 201 patients who underwent primary repair of the peroneus brevis tendon. The average age at time of operation was 44.3 years. Seventy-one patients returned the follow-up questionnaires with an average follow-up of 4.6 years. Fifty-two patients completed the FFI questionnaire preoperatively and postoperatively. Fifty-nine patients (83.1%) reported a return to regular exercise and sports at final follow-up. At 1 year postoperatively, 76.5% of patients returned to the same preinjury activities, and 62.3% returned to the same level of preinjury activity. Furthermore, 85.9% of patients were satisfied with their outcome, and 91.4% of patients reported they would choose to undergo the same procedure again. The mean FAAM score was 85.2 at follow-up. The mean preoperative and postoperative FFI score was 41.1 and 12.2, respectively. There was a significant improvement in the FFI score of 28.9 after primary peroneus brevis tendon repair (P < .001). Primary repair of peroneus brevis tendon provided consistent improvement in functional outcomes in the majority of patients, as measured by a validated scoring system, the FFI. FAAM scores demonstrated good function compared to historical controls. The majority of patients were able to return to preinjury activity. Level IV, retrospective case series. © The Author(s) 2015.

  2. A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair.

    PubMed

    Smith, Christopher D; Alexander, Susan; Hill, Adam M; Huijsmans, Pol E; Bull, Anthony M J; Amis, Andrew A; De Beer, Joe F; Wallace, Andrew L

    2006-11-01

    The optimal method for arthroscopic rotator cuff repair is not yet known. The hypothesis of the present study was that a double-row repair would demonstrate superior static and cyclic mechanical behavior when compared with a single-row repair. The specific aims were to measure gap formation at the bone-tendon interface under static creep loading and the ultimate strength and mode of failure of both methods of repair under cyclic loading. A standardized tear of the supraspinatus tendon was created in sixteen fresh cadaveric shoulders. Arthroscopic rotator cuff repairs were performed with use of either a double-row technique (eight specimens) or a single-row technique (eight specimens) with nonabsorbable sutures that were double-loaded on a titanium suture anchor. The repairs were loaded statically for one hour, and the gap formation was measured. Cyclic loading to failure was then performed. Gap formation during static loading was significantly greater in the single-row group than in the double-row group (mean and standard deviation, 5.0 +/- 1.2 mm compared with 3.8 +/- 1.4 mm; p < 0.05). Under cyclic loading, the double-row repairs failed at a mean of 320 +/- 96.9 N whereas the single-row repairs failed at a mean of 224 +/- 147.9 N (p = 0.058). Three single-row repairs and three double-row repairs failed as a result of suture cut-through. Four single-row repairs and one double-row repair failed as a result of anchor or suture failure. The remaining five repairs did not fail, and a midsubstance tear of the tendon occurred. Although more technically demanding, the double-row technique demonstrates superior resistance to gap formation under static loading as compared with the single-row technique. A double-row reconstruction of the supraspinatus tendon insertion may provide a more reliable construct than a single-row repair and could be used as an alternative to open reconstruction for the treatment of isolated tears.

  3. Functional anatomy of the gibbon forelimb: adaptations to a brachiating lifestyle

    PubMed Central

    Michilsens, Fana; Vereecke, Evie E; D'Août, Kristiaan; Aerts, Peter

    2009-01-01

    It has been shown that gibbons are able to brachiate with very low mechanical costs. The conversion of muscle activity into smooth, purposeful movement of the limb depends on the morphometry of muscles and their mechanical action on the skeleton. Despite the gibbon's reputation for excellence in brachiation, little information is available regarding either its gross musculoskeletal anatomy or its more detailed muscle–tendon architecture. We provide quantitative anatomical data on the muscle–tendon architecture (muscle mass, physiological cross-sectional area, fascicle length and tendon length) of the forelimb of four gibbon species, collected by detailed dissections of unfixed cadavers. Data are compared between different gibbon species and with similar published data of non-brachiating primates such as macaques, chimpanzees and humans. No quantitative differences are found between the studied gibbon species. Both their forelimb anatomy and muscle dimensions are comparable when normalized to the same body mass. Gibbons have shoulder flexors, extensors, rotator muscles and elbow flexors with a high power or work-generating capacity and their wrist flexors have a high force-generating capacity. Compared with other primates, the elbow flexors of gibbons are particularly powerful, suggesting that these muscles are particularly important for a brachiating lifestyle. Based on this anatomical study, the shoulder flexors, extensors, rotator muscles, elbow flexors and wrist flexors are expected to contribute the most to brachiation. PMID:19519640

  4. MR imaging of patients with lateral epicondylitis of the elbow: is the common extensor tendon an isolated lesion?

    PubMed

    Qi, Liang; Zhu, Zheng-Feng; Li, Feng; Wang, Ren-Fa

    2013-01-01

    To investigate whether an injury of the common extensor tendon (CET) is associated with other abnormalities in the elbow joint and find the potential relationships between these imaging features by using a high-resolution magnetic resonance imaging (MRI). Twenty-three patients were examined with 3.0 T MR. Two reviewers were recruited for MR images evaluation. Image features were recorded in terms of (1) the injury degree of CET; (2) associated injuries in the elbow joint. Spearman's rank correlation analysis was performed to analyze the relationships between the injury degree of CET and associated abnormalities of the elbow joint, correlations were considered significant at p<0.05. Total 24 elbows in 23 patients were included. Various degrees of injuries were found in total 24 CETs (10 mild, 7 moderate and 7 severe). Associated abnormalities were detected in accompaniments of the elbow joints including ligaments, tendons, saccussynovialis and muscles. A significantly positive correlation (r = 0.877,p<0.01) was found in injuries of CET and lateral ulnar collateral ligament (LUCL). Injury of the CET is not an isolated lesion for lateral picondylitis, which is mostly accompanied with other abnormalities, of which the LUCL injury is the most commonly seen in lateral epicondylitis, and there is a positive correlation between the injury degree in CET and LUCL.

  5. Acute distal biceps tendon rupture--a new surgical technique using a de-tensioning suture to brachialis.

    PubMed

    Taylor, C J; Bansal, R; Pimpalnerkar, A

    2006-09-01

    Acute distal biceps rupture is a devastating injury in the young athlete and surgical repair offers the only chance of a full recovery. We report a new surgical technique used in 14 cases of acute distal tendon rupture in which the 'suture anchor technique' and a de-tensioning suture was employed. In this procedure the distal end of the biceps is re-attached to the radial tuberosity using a sliding whip stitch suture and the proximal part of the distal tendon repair attached to the underlying brachialis muscle with absorbable sutures. This restores correct anatomical alignment and isometric pull on the distal tendon and de-tensions the repair in the early post-operative period, allowing early rehabilitation and an early return to activity. In all cases patients regained a full pre-injury level of sporting activity at a mean period of 6.2 months (2-9 months).

  6. A review of surgical repair methods and patient outcomes for gluteal tendon tears.

    PubMed

    Ebert, Jay R; Bucher, Thomas A; Ball, Simon V; Janes, Gregory C

    2015-01-01

    Advanced hip imaging and surgical findings have demonstrated that a common cause of greater trochanteric pain syndrome (GTPS) is gluteal tendon tears. Conservative measures are initially employed to treat GTPS and manage gluteal tears, though patients frequently undergo multiple courses of non-operative treatment with only temporary pain relief. Therefore, a number of surgical treatment options for recalcitrant GTPS associated with gluteal tears have been reported. These have included open trans-osseous or bone anchored suture techniques, endoscopic methods and the use of tendon augmentation for repair reinforcement. This review describes the anatomy, pathophysiology and clinical presentation of gluteal tendon tears. Surgical techniques and patient reported outcomes are presented. This review demonstrates that surgical repair can result in improved patient outcomes, irrespective of tear aetiology, and suggests that the patient with "trochanteric bursitis" should be carefully assessed as newer surgical techniques show promise for a condition that historically has been managed conservatively.

  7. Experimental rotator cuff repair. A preliminary study.

    PubMed

    Gerber, C; Schneeberger, A G; Perren, S M; Nyffeler, R W

    1999-09-01

    The repair of chronic, massive rotator cuff tears is associated with a high rate of failure. Prospective studies comparing different repair techniques are difficult to design and carry out because of the many factors that influence structural and clinical outcomes. The objective of this study was to develop a suitable animal model for evaluation of the efficacy of different repair techniques for massive rotator cuff tears and to use this model to compare a new repair technique, tested in vitro, with the conventional technique. We compared two techniques of rotator cuff repair in vivo using the left shoulders of forty-seven sheep. With the conventional technique, simple stitches were used and both suture ends were passed transosseously and tied over the greater tuberosity of the humerus. With the other technique, the modified Mason-Allen stitch was used and both suture ends were passed transosseously and tied over a cortical-bone-augmentation device. This device consisted of a poly(L/D-lactide) plate that was fifteen millimeters long, ten millimeters wide, and two millimeters thick. Number-3 braided polyester suture material was used in all of the experiments. In pilot studies (without prevention of full weight-bearing), most repairs failed regardless of the technique that was used. The simple stitch always failed by the suture pulling through the tendon or the bone; the suture material did not break or tear. The modified Mason-Allen stitch failed in only two of seventeen shoulders. In ten shoulders, the suture material failed even though the stitches were intact. Thus, we concluded that the modified Mason-Allen stitch is a more secure method of achieving suture purchase in the tendon. In eight of sixteen shoulders, the nonaugmented double transosseous bone-fixation technique failed by the suture pulling through the bone. The cortical-bone-augmentation technique never failed. In definite studies, prevention of full weight-bearing was achieved by fixation of a ten-centimeter-diameter ball under the hoof of the sheep. This led to healing in eight of ten shoulders repaired with the modified Mason-Allen stitch and cortical-bone augmentation. On histological analysis, both the simple-stitch and the modified Mason-Allen technique caused similar degrees of transient localized tissue damage. Mechanical pullout tests of repairs with the new technique showed a failure strength that was approximately 30 percent of that of an intact infraspinatus tendon at six weeks, 52 percent of that of an intact tendon at three months, and 81 percent of that of an intact tendon at six months. The repair technique with a modified Mason-Allen stitch with number-3 braided polyester suture material and cortical-bone augmentation was superior to the conventional repair technique. Use of the modified Mason-Allen stitch and the cortical-bone-augmentation device transferred the weakest point of the repair to the suture material rather than to the bone or the tendon. Failure to protect the rotator cuff post-operatively was associated with an exceedingly high rate of failure, even if optimum repair technique was used. Different techniques for rotator cuff repair substantially influence the rate of failure. A modified Mason-Allen stitch does not cause tendon necrosis, and use of this stitch with cortical-bone augmentation yields a repair that is biologically well tolerated and stronger in vivo than a repair with the conventional technique. Unprotected repairs, however, have an exceedingly high rate of failure even if optimum repair technique is used. Postoperative protection from tension overload, such as with an abduction splint, may be necessary for successful healing of massive rotator cuff tears.

  8. A systematic review of tibialis anterior tendon rupture treatments and outcomes.

    PubMed

    Christman-Skieller, Claudia; Merz, Michael K; Tansey, Joseph P

    2015-04-01

    Tibialis anterior (TA) tendon rupture is a relatively rare injury that has been documented primarily in case reports. This article is the first large systematic review of the literature on treatment techniques for subcutaneous rupture of TA tendons. Studies for review were identified through a PubMed search. Eligible studies involved cases of closed tendon rupture. Of the 87 cases in the study, 72 were treated with surgery, 15 with conservative measures. Mean age was 63.9 years (surgery group) and 72.4 years (conservative treatment group). Primary repair was used most often for newer injuries, autograft most often for older injuries. Operative repair of subcutaneous TA tendon rupture leads to successful outcomes in many patients. A surgeon who is deciding which operative technique to use for a patient should consider the age of the injury and the findings of intraoperative assessment for tendon necrosis.

  9. Augmentation with an ovine forestomach matrix scaffold improves histological outcomes of rotator cuff repair in a rat model.

    PubMed

    Street, Matthew; Thambyah, Ashvin; Dray, Michael; Amirapu, Satya; Tuari, Donna; Callon, Karen E; McIntosh, Julie D; Burkert, Kristina; Dunbar, P Rod; Coleman, Brendan; Cornish, Jillian; Musson, David S

    2015-10-20

    Rotator cuff tears can cause significant pain and functional impairment. Without surgical repair, the rotator cuff has little healing potential, and following surgical repair, they are highly prone to re-rupture. Augmenting such repairs with a biomaterial scaffold has been suggested as a potential solution. Extracellular matrix (ECM)-based scaffolds are the most commonly used rotator cuff augments, although to date, reports on their success are variable. Here, we utilize pre-clinical in vitro and in vivo assays to assess the efficacy of a novel biomaterial scaffold, ovine forestomach extracellular matrix (OFM), in augmenting rotator cuff repair. OFM was assessed in vitro for primary tenocyte growth and adherence, and for immunogenicity using an assay of primary human dendritic cell activation. In vivo, using a murine model, supraspinatus tendon repairs were carried out in 34 animals. Augmentation with OFM was compared to sham surgery and unaugmented control. At 6- and 12-week time points, the repairs were analysed biomechanically for strength of repair and histologically for quality of healing. OFM supported tenocyte growth in vitro and did not cause an immunogenic response. Augmentation with OFM improved the quality of healing of the repaired tendon, with no evidence of excessive inflammatory response. However, there was no biomechanical advantage of augmentation. The ideal rotator cuff tendon augment has not yet been identified or clinically implemented. ECM scaffolds offer a promising solution to a difficult clinical problem. Here, we have shown improved histological healing with OFM augmentation. Identifying materials that offset the poorer mechanical properties of the rotator cuff post-injury/repair and enhance organised tendon healing will be paramount to incorporating augmentation into surgical treatment of the rotator cuff.

  10. Biomechanical comparison of four double-row speed-bridging rotator cuff repair techniques with or without medial or lateral row enhancement.

    PubMed

    Pauly, Stephan; Fiebig, David; Kieser, Bettina; Albrecht, Bjoern; Schill, Alexander; Scheibel, Markus

    2011-12-01

    Biomechanical comparison of four different Speed-Bridge configurations with or without medial or lateral row reinforcement. Reinforcement of the knotless Speed-Bridge double-row repair technique with additional medial mattress- or lateral single-stitches was hypothesized to improve biomechanical repair stability at time zero. Controlled laboratory study: In 36 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected and shoulders were randomized to four groups: (1) Speed-Bridge technique with single tendon perforation per anchor (STP); (2) Speed-Bridge technique with double tendon perforation per anchor (DTP); (3) Speed-Bridge technique with medial mattress-stitch reinforcement (MMS); (4) Speed-Bridge technique with lateral single-stitch reinforcement (LSS). All repairs were cyclically loaded from 10-60 N up to 10-200 N (20 N stepwise increase) using a material testing device. Forces at 3 and 5 mm gap formation, mode of failure and maximum load to failure were recorded. The MMS-technique with double tendon perforation showed significantly higher ultimate tensile strength (338.9 ± 90.0 N) than DTP (228.3 ± 99.9 N), LSS (188.9 ± 62.5 N) and STP-technique (122.2 ± 33.8 N). Furthermore, the MMS-technique provided increased maximal force resistance until 3 and 5 mm gap formation (3 mm: 77.8 ± 18.6 N; 5 mm: 113.3 ± 36.1 N) compared with LSS, DTP and STP (P < 0.05 for each 3 and 5 mm gap formation). Failure mode was medial row defect by tendon sawing first, then laterally. No anchor pullout occurred. Double tendon perforation per anchor and additional medial mattress stitches significantly enhance biomechanical construct stability at time zero in this ex vivo model when compared with the all-knotless Speed-Bridge rotator cuff repair.

  11. Arthroscopic repair of traumatic isolated subscapularis tendon lesions (Lafosse Type III or IV): a prospective magnetic resonance imaging-controlled case series with 1 year of follow-up.

    PubMed

    Grueninger, Patrick; Nikolic, Nikola; Schneider, Joerg; Lattmann, Thomas; Platz, Andreas; Chmiel, Corinne; Meier, Christoph

    2014-06-01

    The purpose of this study was to prospectively assess the efficacy of arthroscopic repair of isolated high-grade subscapularis (SSC) tendon lesions by means of clinical follow-up combined with magnetic resonance imaging investigations. Between January 2008 and September 2010, 11 patients (9 men and 2 women; mean age, 45 ± 10 years) with Lafosse type III or IV traumatic isolated SSC tendon lesions underwent arthroscopic repair including tenodesis of the long head of the biceps tendon. All patients were preoperatively assessed by clinical examination (Constant-Murley score [CMS]) and contrast-enhanced magnetic resonance arthrography. At 1 year of follow-up, specific clinical SSC tests, the CMS, and the loss of external rotation were evaluated. A native magnetic resonance investigation was performed to assess the structural integrity of the repair. The SSC muscle was compared with its preoperative condition regarding fatty infiltration and size (cross-sectional area). Patient satisfaction was graded from 1 (poor) to 4 (excellent). The mean time interval from trauma to surgery was 3.7 months. A concomitant lesion of the biceps tendon was observed in 10 patients (91%). The mean CMS improved from 44 to 89 points (P < .001). The functional tests showed a significant increase in strength (P < .05) (belly-press test, 4.8 v 2.9; lift-off test, 4.8 v 2.9). The mean loss of external rotation at 0° of abduction was 10° compared with the contralateral side (P < .05). Patient satisfaction was high. Magnetic resonance imaging evaluation showed complete structural integrity of the tendon repair in all studies. The SSC showed a significant decrease in fatty infiltration and increase in the cross-sectional area. Arthroscopic repair of higher-grade isolated SSC lesions provides reliable tendon healing accompanied by excellent functional results 1 year after surgery. Level IV, prospective therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Endoscopic repair of tears of the superficial layer of the distal triceps tendon.

    PubMed

    Heikenfeld, Roderich; Listringhaus, Rico; Godolias, Georgios

    2014-07-01

    The purpose of this study was to evaluate the results after endoscopic repair of partial superficial layer triceps tendon tears. Fourteen patients treated surgically between July 2005 and December 2012 were studied prospectively for 12 months. Indication for surgery was a partial detachment of the triceps tendon from the olecranon that was proved by magnetic resonance imaging (MRI) in all cases. Ten of these patients had chronic olecranon bursitis. All patients were treated with endoscopic surgery including bursectomy and repair of the distal triceps tendon with double-loaded suture anchors. Clinical examination of the patients as well as functional and subjective scores (Mayo Elbow Performance Index [MEPI], Disabilities of the Arm, Shoulder and Hand Score [Quick DASH]) were obtained preoperatively and postoperatively at 6 and 12 months. An isokinetic strength measurement and MRI were performed preoperatively and 12 months after surgery. All 14 patients were completely evaluated. The MEPI and Quick DASH Score improved significantly after the repair at all postoperative examinations. The MEPI gained 29 points, up to 96 points at last follow-up (P < .05), and the Quick DASH Score went down 15.6 points after 12 months to 4.5 points (P < .05). Maximum extension power improved 55.8%, up to 94.7% at last follow-up compared with the contralateral side. Using MRI, we found one reruptured partial tear of the triceps tendon that did not require revision surgery. Although triceps tendon ruptures are generally uncommon, partial superficial tears might be more common than previously described. Once the diagnosis is made, endoscopic repair is a method leading to good clinical results with improved function of the affected elbow. Endoscopic repair of superficial tears of the triceps tendon is able to restore function and strength and leads to excellent clinical results after 1 year. Strength recovers to nearly that of the contralateral side, and serious complications appear to be infrequent. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Failed healing of rotator cuff repair correlates with altered collagenase and gelatinase in supraspinatus and subscapularis tendons.

    PubMed

    Robertson, Catherine M; Chen, Christopher T; Shindle, Michael K; Cordasco, Frank A; Rodeo, Scott A; Warren, Russell F

    2012-09-01

    Despite improvements in arthroscopic rotator cuff repair technique and technology, a significant rate of failed tendon healing persists. Improving the biology of rotator cuff repairs may be an important focus to decrease this failure rate. The objective of this study was to determine the mRNA biomarkers and histological characteristics of repaired rotator cuffs that healed or developed persistent defects as determined by postoperative ultrasound. Increased synovial inflammation and tendon degeneration at the time of surgery are correlated with the failed healing of rotator cuff tendons. Case-control study; Level of evidence, 3. Biopsy specimens from the subscapularis tendon, supraspinatus tendon, glenohumeral synovium, and subacromial bursa of 35 patients undergoing arthroscopic rotator cuff repair were taken at the time of surgery. Expression of proinflammatory cytokines, tissue remodeling genes, and angiogenesis factors was evaluated by quantitative real-time polymerase chain reaction. Histological characteristics of the affected tissue were also assessed. Postoperative (>6 months) ultrasound was used to evaluate the healing of the rotator cuff. General linear modeling with selected mRNA biomarkers was used to predict rotator cuff healing. Thirty patients completed all analyses, of which 7 patients (23%) had failed healing of the rotator cuff. No differences in demographic data were found between the defect and healed groups. American Shoulder and Elbow Surgeons shoulder scores collected at baseline and follow-up showed improvement in both groups, but there was no significant difference between groups. Increased expression of matrix metalloproteinase 1 (MMP-1) and MMP-9 was found in the supraspinatus tendon in the defect group versus the healed group (P = .006 and .02, respectively). Similar upregulation of MMP-9 was also found in the subscapularis tendon of the defect group (P = .001), which was consistent with the loss of collagen organization as determined by histological examination. From a general linear model, the upregulation of MMP-1 and MMP-9 was highly correlated with failed healing of the rotator cuff (R(2) = .656). The upregulation of tissue remodeling genes in the torn rotator cuff at the time of surgery provides a snapshot of the biological environment surrounding the torn rotator cuff that is closely related to the healing of repaired rotator cuffs.

  14. Repair of distal biceps tendon rupture with the Biotenodesis screw.

    PubMed

    Khan, W; Agarwal, M; Funk, L

    2004-04-01

    Distal biceps tendon ruptures are uncommon injuries with only around 300 cases reported in the literature. Current management tends to favour anatomical reinsertion of the tendon into the radial tuberosity, especially in young and active individuals. These injuries are commonly repaired using either a single anterior incision with suture anchors or the Boyd-Anderson dual incision technique. We report the use of a bioabsorbable interference screw for the repair of distal biceps tendon rupture using a minimal incision technique. In this technique the avulsed tendon and a bioabsorbable screw are secured in a drill hole on the radial tuberosity using whip stitch and fibre wire sutures according to Biotenodesis system guidelines. The technique described requires minimal volar dissection that is associated with a reduced number of synostosis and posterior interosseous nerve injuries. The bioabsorbable interference screw has all the advantages of being biodegradable and has been shown to have greater pullout strength than suture anchors. It is also a reasonable alternative to titanium screws in terms of primary fixation strength. The strong fixation provided allows early active motion and return to previous activities as seen in our case.

  15. Inhibition of 5-LOX, COX-1, and COX-2 increases tendon healing and reduces muscle fibrosis and lipid accumulation after rotator cuff repair.

    PubMed

    Oak, Nikhil R; Gumucio, Jonathan P; Flood, Michael D; Saripalli, Anjali L; Davis, Max E; Harning, Julie A; Lynch, Evan B; Roche, Stuart M; Bedi, Asheesh; Mendias, Christopher L

    2014-12-01

    The repair and restoration of function after chronic rotator cuff tears are often complicated by muscle atrophy, fibrosis, and fatty degeneration of the diseased muscle. The inflammatory response has been implicated in the development of fatty degeneration after cuff injuries. Licofelone is a novel anti-inflammatory drug that inhibits 5-lipoxygenase (5-LOX), as well as cyclooxygenase (COX)-1 and COX-2 enzymes, which play important roles in inducing inflammation after injuries. While previous studies have demonstrated that nonsteroidal anti-inflammatory drugs and selective inhibitors of COX-2 (coxibs) may prevent the proper healing of muscles and tendons, studies about bone and cartilage have demonstrated that drugs that inhibit 5-LOX concurrently with COX-1 and COX-2 may enhance tissue regeneration. After the repair of a chronic rotator cuff tear in rats, licofelone would increase the load to failure of repaired tendons and increase the force production of muscle fibers. Controlled laboratory study. Rats underwent supraspinatus release followed by repair 28 days later. After repair, rats began a treatment regimen of either licofelone or a vehicle for 14 days, at which time animals were euthanized. Supraspinatus muscles and tendons were then subjected to contractile, mechanical, histological, and biochemical analyses. Compared with controls, licofelone-treated rats had a grossly apparent decrease in inflammation and increased fibrocartilage formation at the enthesis, along with a 62% increase in the maximum load to failure and a 51% increase in peak stress to failure. Licofelone resulted in a marked reduction in fibrosis and lipid content in supraspinatus muscles as well as reduced expression of several genes involved in fatty infiltration. Despite the decline in fibrosis and fat accumulation, muscle fiber specific force production was reduced by 23%. The postoperative treatment of cuff repair with licofelone may reduce fatty degeneration and enhance the development of a stable bone-tendon interface, although decreases in muscle fiber specific force production were observed, and force production in fact declined. This study demonstrates that the inhibition of 5-LOX, COX-1, and COX-2 modulates the healing process of repaired rotator cuff tendons. Although further studies are necessary, the treatment of patients with licofelone after cuff repair may improve the development of a stable enthesis and enhance postoperative outcomes. © 2014 The Author(s).

  16. rhPDGF-BB promotes early healing in a rat rotator cuff repair model.

    PubMed

    Kovacevic, David; Gulotta, Lawrence V; Ying, Liang; Ehteshami, John R; Deng, Xiang-Hua; Rodeo, Scott A

    2015-05-01

    Tendon-bone healing after rotator cuff repair occurs by fibrovascular scar tissue formation, which is weaker than a normal tendon-bone insertion site. Growth factors play a role in tissue formation and have the potential to augment soft tissue healing in the perioperative period. Our study aim was to determine if rhPDGF-BB delivery on a collagen scaffold can improve tendon-to-bone healing after supraspinatus tendon repair compared with no growth factor in rats as measured by (1) gross observations; (2) histologic analysis; and (3) biomechanical testing. Ninety-five male Sprague-Dawley rats underwent acute repair of the supraspinatus tendon. Rats were randomized into one of five groups: control (ie, repair only), scaffold only, and three different platelet-derived growth factor (PDGF) doses on the collagen scaffold. Animals were euthanized 5 days after surgery to assess cellular proliferation and angiogenesis. The remaining animals were analyzed at 4 weeks to assess repair site integrity by gross visualization, fibrocartilage formation with safranin-O staining, and collagen fiber organization with picrosirius red staining, and to determine the biomechanical properties (ie, load-to-failure testing) of the supraspinatus tendon-bone construct. The repaired supraspinatus tendon was in continuity with the bone in all animals. At 5 days, rhPDGF-BB delivery on a scaffold demonstrated a dose-dependent response in cellular proliferation and angiogenesis compared with the control and scaffold groups. At 28 days, with the numbers available, rhPDGF-BB had no effect on increasing fibrocartilage formation or improving collagen fiber maturity at the tendon-bone insertion site compared with controls. The control group had higher tensile loads to failure and stiffness (35.5 ± 8.8 N and 20.3 ± 4.5 N/mm) than all the groups receiving the scaffold, including the PDGF groups (scaffold: 27 ± 6.4 N, p = 0.021 and 13 ± 5.7 N/mm, p = 0.01; 30 µg/mL PDGF: 26.5 ± 7.5 N, p = 0.014 and 13.3 ± 3.2 N/mm, p = 0.01; 100 µg/mL PDGF: 25.7 ± 6.1 N, p = 0.005 and 11.6 ± 3.3 N/mm, p = 0.01; 300 µg/mL PDGF: 27 ± 6.9 N, p = 0.014 and 12.7 ± 4.1 N/mm, p = 0.01). rhPDGF-BB delivery on a collagen scaffold enhanced cellular proliferation and angiogenesis during the early phase of healing, but this did not result in either a more structurally organized or stronger attachment site at later stages of healing. The collagen scaffold had a detrimental effect on healing strength at 28 days, and its relatively larger size compared with the rat tendon may have caused mechanical impingement and extrinsic compression of the healing tendon. Future studies should be performed in larger animal models where healing occurs more slowly. Augmenting the healing environment to improve the structural integrity and to reduce the retear rate after rotator cuff repair may be realized with continued understanding and optimization of growth factor delivery systems.

  17. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    PubMed

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  18. Cell-laden composite suture threads for repairing damaged tendons.

    PubMed

    Costa-Almeida, Raquel; Domingues, Rui M A; Fallahi, Afsoon; Avci, Huseyin; Yazdi, Iman K; Akbari, Mohsen; Reis, Rui L; Tamayol, Ali; Gomes, Manuela E; Khademhosseini, Ali

    2018-04-01

    Tendons have limited regenerative capacity due to their low cellularity and hypovascular nature, which results in poor clinical outcomes of presently used therapies. As tendon injuries are often observed in active adults, it poses an increasing socio-economic burden on healthcare systems. Currently, suture threads are used during surgical repair to anchor the tissue graft or to connect injured ends. Here, we created composite suture threads coated with a layer of cell-laden hydrogel that can be used for bridging the injured tissue aiming at tendon regeneration. In addition, the fibres can be used to engineer 3-dimensional constructs through textile processes mimicking the architecture and mechanical properties of soft tissues, including tendons and ligaments. Encapsulated human tendon-derived cells migrated within the hydrogel and aligned at the surface of the core thread. An up-regulation of tendon-related genes (scleraxis and tenascin C) and genes involved in matrix remodelling (matrix metalloproteinases 1, matrix metalloproteinases 2) was observed. Cells were able to produce a collagen-rich matrix, remodelling their micro-environment, which is structurally comparable to native tendon tissue. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Patellar tendon vibration reduces the increased facilitation from quadriceps to soleus in post-stroke hemiparetic individuals.

    PubMed

    Maupas, Eric; Dyer, Joseph-Omer; Melo, Sibele de Andrade; Forget, Robert

    2017-09-01

    Stimulation of the femoral nerve in healthy people can facilitate soleus H-reflex and electromyography (EMG) activity. In stroke patients, such facilitation of transmission in spinal pathways linking the quadriceps and soleus muscles is enhanced and related to co-activation of knee and ankle extensors while sitting and walking. Soleus H-reflex facilitation can be depressed by vibration of the quadriceps in healthy people, but the effects of such vibration have never been studied on the abnormal soleus facilitation observed in people after stroke. To determine whether vibration of the quadriceps can modify the enhanced heteronymous facilitation of the soleus muscle observed in people with spastic stroke after femoral nerve stimulation and compare post-vibration effects on soleus facilitation in control and stroke individuals. Modulation of voluntary soleus EMG activity induced by femoral nerve stimulation (2×motor threshold) was assessed before, during and after vibration of the patellar tendon in 10 healthy controls and 17 stroke participants. Voluntary soleus EMG activity was facilitated by femoral nerve stimulation in 4/10 (40%) controls and 11/17 (65%) stroke participants. The level of facilitation was greater in the stroke than control group. Vibration significantly reduced early heteronymous facilitation in both groups (50% of pre-vibration values). However, the delay in recovery of soleus facilitation after vibration was shorter for the stroke than control group. The control condition with the vibrator turned off had no effect on the modulation. Patellar tendon vibration can reduce the facilitation between knee and ankle extensors, which suggests effective presynaptic inhibition but decreased post-activation depression in the lower limb of people after chronic hemiparetic stroke. Further studies are warranted to determine whether such vibration could be used to reduce the abnormal extension synergy of knee and ankle extensors in people after hemiparetic stroke. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Proprioceptive guidance of human voluntary wrist movements studied using muscle vibration.

    PubMed Central

    Cody, F W; Schwartz, M P; Smit, G P

    1990-01-01

    1. The alterations in voluntary wrist extension and flexion movement trajectories induced by application of vibration to the tendon of flexor carpi radialis throughout the course of the movement, together with the associated EMG patterns, have been studied in normal human subjects. Both extension and flexion movements were routinely of a target amplitude of 30 deg and made against a torque load of 0.32 N m. Flexor tendon vibration consistently produced undershooting of voluntary extension movements. In contrast, voluntary flexion movements were relatively unaffected. 2. The degree of vibration-induced undershooting of 1 s voluntary extension movements was graded according to the amplitude (0.75, 1.0 and 1.5 mm) of flexor tendon vibration. 3. As flexor vibration was initiated progressively later (at greater angular thresholds) during the course of 1 s voluntary extension movements, and the period of vibration was proportionately reduced, so the degree of vibration-induced undershooting showed a corresponding decline. 4. Varying the torque loads (0.32, 0.65 and 0.97 N m) against which 1 s extension movements were made, and thereby the strength of voluntary extensor contraction, produced no systematic changes in the degree of flexor vibration-induced undershooting. 5. Analysis of EMG patterns recorded from wrist flexor and extensor muscles indicated that vibration-induced undershooting of extension movements resulted largely from a reduction in activity in the prime-mover rather than increased antagonist activity. The earliest reductions in extensor EMG commenced some 40 ms after the onset of vibration, i.e. well before voluntary reaction time; these initial responses were considered to be 'automatic' in nature. 6. These results support the view that the central nervous system utilizes proprioceptive information in the continuous regulation of moderately slow voluntary wrist movements. Proprioceptive sensory input from the passively lengthening antagonist muscle, presumably arising mainly from muscle spindle I a afferents, appears to be particularly important and to act mainly in the reciprocal control of the prime-mover. PMID:2213604

  1. Comparison of the Tendon Damage Caused by Four Different Anchor Systems Used in Transtendon Rotator Cuff Repair

    PubMed Central

    Zhang, Qing-Song; Liu, Sen; Zhang, Qiuyang; Xue, Yun; Ge, Dongxia; O'Brien, Michael J.; Savoie, Felix H.; You, Zongbing

    2012-01-01

    Objectives. The objective of this study was to compare the damage to the rotator cuff tendons caused by four different anchor systems. Methods. 20 cadaveric human shoulder joints were used for transtendon insertion of four anchor systems. The Healix Peek, Fastin RC, Bio-Corkscrew Suture, and Healix Transtend anchors were inserted through the tendons using standard transtendon procedures. The areas of tendon damage were measured. Results. The areas of tendon damage (mean ± standard deviation, n = 7) were 29.1 ± 4.3 mm2 for the Healix Peek anchor, 20.4 ± 2.3 mm2 for the Fastin RC anchor, 23.4 ± 1.2 mm2 for the Bio-Corkscrew Suture anchor, 13.7 ± 3.2 mm2 for the Healix Transtend anchor inserted directly, and 9.1 ± 2.1 mm2 for the Healix Transtend anchor inserted through the Percannula system (P < 0.001 or P < 0.001, compared to other anchors). Conclusions. In a cadaver transtendon rotator cuff repair model, smaller anchors caused less damage to the tendon tissues. The Healix Transtend implant system caused the least damage to the tendon tissues. Our findings suggest that smaller anchors should be considered when performing transtendon procedures to repair partial rotator cuff tears. PMID:22811923

  2. Delayed repair of distal biceps tendon ruptures is successful: a case-control study.

    PubMed

    Haverstock, John; Grewal, Ruby; King, Graham J W; Athwal, George S

    2017-06-01

    The literature has shown an increased complication rate with a delay to surgical repair of acute distal biceps tendon ruptures; however, little has been documented regarding the outcome of delayed repairs. This case-control study compared a study cohort of delayed (>21 days) distal biceps tendon repairs with a control cohort repaired acutely (<21 days). Sixteen delayed repair cases were reviewed and matched with acute controls (1:3) based on repair technique, age, and workers' compensation status. The delayed cohort was reviewed and completed isometric strength testing and the Disabilities of the Arm, Shoulder and Hand questionnaire; Patient-Rated Elbow Evaluation; and American Shoulder and Elbow Surgeons elbow questionnaire. The time to surgery averaged 37 ± 12 days in the delayed cohort versus 10 ± 6 days in the acute cohort. Complications occurred in 63% of patients in the delayed cohort versus 29% in the acute cohort (P = .04); however, 90% of the delayed cohort's complications consisted of transient paresthesias. Follow-up scores on the Patient-Rated Elbow Evaluation, Disabilities of the Arm, Shoulder and Hand questionnaire, and American Shoulder and Elbow Surgeons elbow questionnaire were not statistically different between cohorts (P > .37, P > .22, and P > .46, respectively). Despite a high rate of initial complications, patients treated with distal biceps tendon repair after a delay (>21 days) can expect similar functional outcomes to those treated acutely. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Biomechanical evaluation of a single-row versus double-row repair for complete subscapularis tears.

    PubMed

    Wellmann, Mathias; Wiebringhaus, Philipp; Lodde, Ina; Waizy, Hazibullah; Becher, Christoph; Raschke, Michael J; Petersen, Wolf

    2009-12-01

    The purpose of the study was to compare a single-row repair and a double-row repair technique for the specific characteristics of a complete subscapularis lesion. Ten pairs of human cadaveric shoulder human shoulder specimens were tested for stiffness and ultimate tensile strength of the intact tendons in a load to failure protocol. After a complete subscapularis tear was provoked, the specimens were assigned to two treatment groups: single-row repair (1) and a double-row repair using a "suture bridge" technique (2). After repair cyclic loading a subsequent load to failure protocol was performed to determine the ultimate tensile load, the stiffness and the elongation behaviour of the reconstructions. The intact subscapularis tendons had a mean stiffness of 115 N/mm and a mean ultimate load of 720 N. The predominant failure mode of the intact tendons was a tear at the humeral insertion site (65%). The double-row technique restored 48% of the ultimate load of the intact tendons (332 N), while the single-row technique revealed a significantly lower ultimate load of 244 N (P = 0.001). In terms of the stiffness, the double-row technique showed a mean stiffness of 81 N/mm which is significantly higher compared to the stiffness of the single-row repairs of 55 N/mm (P = 0.001). The double-row technique has been shown to be stronger and stiffer when compared to a conventional single-row repair. Therefore, this technique is recommended from a biomechanical point of view irrespectively if performed by an open or arthroscopic approach.

  4. Effect of Adipose-Derived Stromal Cells and BMP12 on Intrasynovial Tendon Repair: A Biomechanical, Biochemical, and Proteomics Study

    PubMed Central

    Gelberman, Richard H.; Shen, Hua; Kormpakis, Ioannis; Rothrauff, Benjamin; Yang, Guang; Tuan, Rocky S.; Xia, Younan; Sakiyama-Elbert, Shelly; Silva, Matthew J.; Thomopoulos, Stavros

    2016-01-01

    The outcomes of flexor tendon repair are highly variable. As recent efforts to improve healing have demonstrated promise for growth factor- and cell-based therapies, the objective of the current study was to enhance repair via application of autologous adipose derived stromal cells (ASCs) and the tenogenic growth factor bone morphogenetic protein (BMP) 12. Controlled delivery of cells and growth factor was achieved in a clinically relevant canine model using a nanofiber/fibrin-based scaffold. Control groups consisted of repair-only (no scaffold) and acellular scaffold. Repairs were evaluated after 28 days of healing using biomechanical, biochemical, and proteomics analyses. Range of motion was reduced in the groups that received scaffolds compared to normal. There was no effect of ASC+BMP12 treatment for range of motion or tensile properties outcomes versus repair-only. Biochemical assays demonstrated increased DNA, glycosaminoglycans, and crosslink concentration in all repair groups compared to normal, but no effect of ASC+BMP12. Total collagen was significantly decreased in the acellular scaffold group compared to normal and significantly increased in the ASC+BMP12 group compared to the acellular scaffold group. Proteomics analysis comparing healing tendons to uninjured tendons revealed significant increases in proteins associated with inflammation, stress response, and matrix degradation. Treatment with ASC+BMP12 amplified these unfavorable changes. In summary, the treatment approach used in this study induced a negative inflammatory reaction at the repair site leading to poor healing. Future approaches should consider cell and growth factor delivery methods that do not incite negative local reactions. PMID:26445383

  5. Influence of preoperative musculotendinous junction position on rotator cuff healing using single-row technique.

    PubMed

    Tashjian, Robert Z; Hung, Man; Burks, Robert T; Greis, Patrick E

    2013-11-01

    The purpose of this study was to evaluate the correlation of rotator cuff musculotendinous junction (MTJ) retraction with healing after rotator cuff repair and with preoperative sagittal tear size. We reviewed preoperative and postoperative magnetic resonance imaging (MRI) studies of 51 patients undergoing arthroscopic single-row rotator cuff repair between March 1, 2005, and February 20, 2010. Preoperative MRI studies were evaluated for anteroposterior tear size, tendon retraction, tendon length, muscle quality, and MTJ position with respect to the glenoid. The position of the MTJ was referenced off the glenoid face as either lateral or medial. Postoperative MRI studies obtained at a minimum of 1 year postoperatively (mean, 25 ± 13.9 months) were evaluated for healing, tendon length, and MTJ position. We found that 39 of 51 tears (76%) healed, with 26 of 30 small/medium tears (87%) and 13 of 21 large/massive tears (62%) healing. Greater tendon retraction, worse preoperative muscle quality, and a more medialized MTJ were all associated with worse tendon healing (P < .05). Of tears that had a preoperative MTJ lateral to the face of the glenoid, 93% healed, whereas only 55% of tears that had a preoperative MTJ medial to the face of the glenoid healed (P < .05). Healed repairs that had limited tendon lengthening (<1 cm) and limited MTJ position change (<1 cm) from preoperative were found to be smaller, had less preoperative tendon retraction, had less preoperative MTJ medialization, and had less preoperative rotator cuff fatty infiltration (P < .05). Preoperative MTJ medialization, tendon retraction, and muscle quality are all predictive of tendon healing postoperatively when using a single-row rotator cuff repair technique. The position of the MTJ with respect to the glenoid face can be predictive of healing, with over 90% healing if lateral and 50% if medial to the face. Lengthening of the tendon accounts for a significant percentage of the musculotendinous unit lengthening that occurs in healed tears as opposed to muscle elongation. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. The effects of platelet lysate patches on the activity of tendon-derived cells.

    PubMed

    Costa-Almeida, Raquel; Franco, Albina R; Pesqueira, Tamagno; Oliveira, Mariana B; Babo, Pedro S; Leonor, Isabel B; Mano, João F; Reis, Rui L; Gomes, Manuela E

    2018-03-01

    Platelet-derived biomaterials are widely explored as cost-effective sources of therapeutic factors, holding a strong potential for endogenous regenerative medicine. Particularly for tendon repair, treatment approaches that shift the injury environment are explored to accelerate tendon regeneration. Herein, genipin-crosslinked platelet lysate (PL) patches are proposed for the delivery of human-derived therapeutic factors in patch augmentation strategies aiming at tendon repair. Developed PL patches exhibited a controlled release profile of PL proteins, including bFGF and PDGF-BB. Additionally, PL patches exhibited an antibacterial effect by preventing the adhesion, proliferation and biofilm formation by S. aureus, a common pathogen in orthopaedic surgical site infections. Furthermore, these patches supported the activity of human tendon-derived cells (hTDCs). Cells were able to proliferate over time and an up-regulation of tenogenic genes (SCX, COL1A1 and TNC) was observed, suggesting that PL patches may modify the behavior of hTDCs. Accordingly, hTDCs deposited tendon-related extracellular matrix proteins, namely collagen type I and tenascin C. In summary, PL patches can act as a reservoir of biomolecules derived from PL and support the activity of native tendon cells, being proposed as bioinstructive patches for tendon regeneration. Platelet-derived biomaterials hold great interest for the delivery of therapeutic factors for applications in endogenous regenerative medicine. In the particular case of tendon repair, patch augmentation strategies aiming at shifting the injury environment are explored to improve tendon regeneration. In this study, PL patches were developed with remarkable features, including the controlled release of growth factors and antibacterial efficacy. Remarkably, PL patches supported the activity of native tendon cells by up-regulating tenogenic genes and enabling the deposition of ECM proteins. This patch holds great potential towards simultaneously reducing post-implantation surgical site infections and promoting tendon regeneration for prospective in vivo applications. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  7. Nerve transfers in tetraplegia I: Background and technique

    PubMed Central

    Brown, Justin M.

    2011-01-01

    Background: The recovery of hand function is consistently rated as the highest priority for persons with tetraplegia. Recovering even partial arm and hand function can have an enormous impact on independence and quality of life of an individual. Currently, tendon transfers are the accepted modality for improving hand function. In this procedure, the distal end of a functional muscle is cut and reattached at the insertion site of a nonfunctional muscle. The tendon transfer sacrifices the function at a lesser location to provide function at a more important location. Nerve transfers are conceptually similar to tendon transfers and involve cutting and connecting a healthy but less critical nerve to a more important but paralyzed nerve to restore its function. Methods: We present a case of a 28-year-old patient with a C5-level ASIA B (international classification level 1) injury who underwent nerve transfers to restore arm and hand function. Intact peripheral innervation was confirmed in the paralyzed muscle groups corresponding to finger flexors and extensors, wrist flexors and extensors, and triceps bilaterally. Volitional control and good strength were present in the biceps and brachialis muscles, the deltoid, and the trapezius. The patient underwent nerve transfers to restore finger flexion and extension, wrist flexion and extension, and elbow extension. Intraoperative motor-evoked potentials and direct nerve stimulation were used to identify donor and recipient nerve branches. Results: The patient tolerated the procedure well, with a preserved function in both elbow flexion and shoulder abduction. Conclusions: Nerve transfers are a technically feasible means of restoring the upper extremity function in tetraplegia in cases that may not be amenable to tendon transfers. PMID:21918736

  8. Ia Afferent input alters the recruitment thresholds and firing rates of single human motor units.

    PubMed

    Grande, G; Cafarelli, E

    2003-06-01

    Vibration of the patellar tendon recruits motor units in the knee extensors via excitation of muscle spindles and subsequent Ia afferent input to the alpha-motoneuron pool. Our first purpose was to determine if the recruitment threshold and firing rate of the same motor unit differed when recruited involuntarily via reflex or voluntarily via descending spinal pathways. Although Ia input is excitatory to the alpha-motoneuron pool, it has also been shown paradoxically to inhibit itself. Our second purpose was to determine if vibration of the patellar tendon during a voluntary knee extension causes a change in the firing rate of already recruited motor units. In the first protocol, 10 subjects voluntarily reproduced the same isometric force profile of the knee extensors that was elicited by vibration of the patellar tendon. Single motor unit recordings from the vastus lateralis (VL) were obtained with tungsten microelectrodes and unitary behaviour was examined during both reflex and voluntary knee extensions. Recordings from 135 single motor units showed that both recruitment thresholds and firing rates were lower during reflex contractions. In the second protocol, 7 subjects maintained a voluntary knee extension at 30 N for approximately 40-45 s. Three bursts of patellar tendon vibration were superimposed at regular intervals throughout the contraction and changes in the firing rate of already recruited motor units were examined. A total of 35 motor units were recorded and each burst of superimposed vibration caused a momentary reduction in the firing rates and recruitment of additional units. Our data provide evidence that Ia input modulates the recruitment thresholds and firing rates of motor units providing more flexibility within the neuromuscular system to grade force at low levels of force production.

  9. FUNCTIONAL OUTCOMES AFTER DISTAL BICEPS BRACHII REPAIR: A CASE SERIES

    PubMed Central

    Morris, Tim; Otto, Charissa; Zerella, Tanisha; Semmler, John G; Human, Taaibos; Phadnis, Joideep; Bain, Gregory I

    2016-01-01

    Objectives To investigate outcomes after surgical repair of distal biceps tendon rupture and the influence of arm dominance on isokinetic flexion and supination results. Background/Purpose While relatively uncommon, rupture of the distal biceps tendon can result in significant strength deficits, for which surgical repair is recommended. The purpose of this study was to assess patient reported functional outcomes and muscle performance following surgery. Methods A sample of 23 participants (22 males, 1 female), who had previously undergone surgical repair of the distal biceps tendon, were re-examined at a minimum of one year after surgery. Biodex isokinetic elbow flexion and supination testing was performed to assess strength (as measured by peak torque) and endurance (as measured by total work and work fatigue). The Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) and Mayo Elbow Performance Scale (MEPS) were used to assess participants' subjectively reported functional recovery. Results At a mean of 7.6 years after surgical repair, there were no differences between the repaired and uninvolved elbows in peak torque (p = 0.47) or total work (p = 0.60) for flexion or supination. There was also no difference in elbow flexion work fatigue (p = 0.22). However, there was significantly less work fatigue in supination, which was likely influenced by arm dominance, as most repairs were to the dominant arm, F(1,22)=5.67, p = 0.03. Conclusion The long-term strength of the repaired elbow was similar to the uninvolved elbow after surgery to the distal biceps tendon. Endurance of the repaired elbow was similar in flexion but greater in supination, probably influenced by arm dominance. Study design Retrospective case series Level of Evidence Level 4 PMID:27904798

  10. FUNCTIONAL OUTCOMES AFTER DISTAL BICEPS BRACHII REPAIR: A CASE SERIES.

    PubMed

    Redmond, Christine L; Morris, Tim; Otto, Charissa; Zerella, Tanisha; Semmler, John G; Human, Taaibos; Phadnis, Joideep; Bain, Gregory I

    2016-12-01

    To investigate outcomes after surgical repair of distal biceps tendon rupture and the influence of arm dominance on isokinetic flexion and supination results. While relatively uncommon, rupture of the distal biceps tendon can result in significant strength deficits, for which surgical repair is recommended. The purpose of this study was to assess patient reported functional outcomes and muscle performance following surgery. A sample of 23 participants (22 males, 1 female), who had previously undergone surgical repair of the distal biceps tendon, were re-examined at a minimum of one year after surgery. Biodex isokinetic elbow flexion and supination testing was performed to assess strength (as measured by peak torque) and endurance (as measured by total work and work fatigue). The Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) and Mayo Elbow Performance Scale (MEPS) were used to assess participants' subjectively reported functional recovery. At a mean of 7.6 years after surgical repair, there were no differences between the repaired and uninvolved elbows in peak torque ( p  = 0.47) or total work ( p  = 0.60) for flexion or supination. There was also no difference in elbow flexion work fatigue ( p  = 0.22). However, there was significantly less work fatigue in supination, which was likely influenced by arm dominance, as most repairs were to the dominant arm, F (1,22)=5.67, p  = 0.03. The long-term strength of the repaired elbow was similar to the uninvolved elbow after surgery to the distal biceps tendon. Endurance of the repaired elbow was similar in flexion but greater in supination, probably influenced by arm dominance. Retrospective case series. Level 4.

  11. Isolated avulsion of the vastus lateralis tendon insertion in a weightlifter: a case report.

    PubMed

    Phadnis, Joideep; Trikha, Paul S; Wood, David G

    2009-08-25

    We report a case of isolated, unilateral avulsion of the vastus lateralis tendon from its insertion at the patella. This was diagnosed by magnetic resonance imaging, and underwent successful surgical repair. A healthy 32-year-old national level power lifter presented with an isolated avulsion of the vastus lateralis tendon. After a failed course of conservative therapy he underwent surgical repair and a graded physical therapy programme. One year later he returned to full training with no evidence of re-rupture. This is the first reported case of an isolated vastus lateralis avulsion. Our experience suggests that magnetic resonance imaging is invaluable in the diagnosis of this condition and that surgical repair provides a good outcome in high demand patients.

  12. Matrix metabolism rate differs in functionally distinct tendons.

    PubMed

    Birch, Helen L; Worboys, Sarah; Eissa, Sabry; Jackson, Brendan; Strassburg, Sandra; Clegg, Peter D

    2008-04-01

    Tendon matrix integrity is vital to ensure adequate mechanical properties for efficient function. Although historically tendon was considered to be relatively inert, recent studies have shown that tendon matrix turnover is active. During normal physiological activities some tendons are subjected to stress and strains much closer to their failure properties than others. Tendons with low safety margins are those which function as energy stores such as the equine superficial digital flexor tendon (SDFT) and human Achilles tendon (AT). We postulate therefore that energy storing tendons suffer a higher degree of micro-damage and thus have a higher rate of matrix turnover than positional tendons. The hypothesis was tested using tissue from the equine SDFT and common digital extensor tendon (CDET). Matrix turnover was assessed indirectly by a combination of measurements for matrix age, markers of degradation, potential for degradation and protein expression. Results show that despite higher cellularity, the SDFT has lower relative levels of mRNA for collagen types I and III. Non-collagenous proteins, although expressed at different levels per cell, do not appear to differ between tendon types. Relative levels of mRNA for MMP1, MMP13 and both pro-MMP3 and MMP13 protein activity were significantly higher in the CDET. Correspondingly levels of cross-linked carboxyterminal telopeptide of type I collagen (ICTP) were higher in the CDET and tissue fluorescence lower suggesting more rapid turnover of the collagenous component. Reduced or inhibited collagen turnover in the SDFT may account for the high level of degeneration and subsequent injury compared to the CDET.

  13. Biomechanical Cadaveric Evaluation of Partial Acute Peroneal Tendon Tears.

    PubMed

    Wagner, Emilio; Wagner, Pablo; Ortiz, Cristian; Radkievich, Ruben; Palma, Felipe; Guzmán-Venegas, Rodrigo

    2018-06-01

    No clear guideline or solid evidence exists for peroneal tendon tears to determine when to repair, resect, or perform a tenodesis on the damaged tendon. The objective of this study was to analyze the mechanical behavior of cadaveric peroneal tendons artificially damaged and tested in a cyclic and failure mode. The hypothesis was that no failure would be observed in the cyclic phase. Eight cadaveric long leg specimens were tested on a specially designed frame. A longitudinal full thickness tendon defect was created, 3 cm in length, behind the tip of the fibula, compromising 66% of the visible width of the peroneal tendons. Cyclic testing was initially performed between 50 and 200 N, followed by a load-to-failure test. Tendon elongation and load to rupture were measured. No tendon failed or lengthened during cyclic testing. The mean load to failure for peroneus brevis was 416 N (95% confidence interval, 351-481 N) and for the peroneus longus was 723 N (95% confidence interval, 578-868 N). All failures were at the level of the defect created. In a cadaveric model of peroneal tendon tears, 33% of remaining peroneal tendon could resist high tensile forces, above the physiologic threshold. Some peroneal tendon tears can be treated conservatively without risking spontaneous ruptures. When surgically treating a symptomatic peroneal tendon tear, increased efforts may be undertaken to repair tears previously considered irreparable.

  14. Proximity of the Triangular Fibrocartilage Complex to Key Surrounding Structures and Safety Assessment of an Arthroscopic Repair Technique: A Cadaveric Study.

    PubMed

    Kuremsky, Marshall A; Habet, Nahir; Peindl, Richard D; Gaston, R Glenn

    2016-12-01

    To quantify the distance of the dorsal ulnar sensory branch, floor of the extensor carpi ulnaris (ECU) subsheath, and ulnar neurovascular bundles from the triangular fibrocartilage complex (TFCC), and secondarily to assess the safety of an all-inside arthroscopic repair of the TFCC with a commonly used meniscal repair device with respect to the aforementioned structures. A custom K-wire with 1-mm gradation was used to determine the distance of at-risk structures from the periphery of the TFCC in 13 above-elbow human cadaver specimens. An all-inside repair of the TFCC at the location of a Palmer 1B tear was then performed using a commonly employed meniscal repair device. The distance from the deployed devices to the structure in closest proximity was then measured using digital calipers. The mean distance from the deployed device to the nearest structure of concern for iatrogenic injury was 9.4 mm (range, 5-15 mm). The closest structure to iatrogenic injury was usually, but not always, the dorsal ulnar sensory nerve in 9 of 13 wrists (69.2%) at 9.3 mm (range, 5-15 mm); on 3 occasions it was instead the ulnar nerve (23.1%) at 9.5 mm (range, 9-10 mm), and on 1 occasion 6 mm from the flexor digitorum profundus to the little finger (7.7%). Forearm rotation had no significant effect on measured distances (ulnar nerve: P = .98; dorsal sensory: P = .89; ECU: P = .90). The largest influence of forearm rotation was a 0.4-mm difference between pronation and supination with respect to the distance of the TFCC periphery on the ECU subsheath. An all-inside arthroscopic TFCC repair using a commonly used meniscal repair device appears safe with respect to nearby neurovascular structures and tendons under typical arthroscopic conditions. An all-inside arthroscopic TFCC repair using a commonly employed meniscal repair device appears safe in terms of proximity to important structures although further clinical investigation is warranted. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Does immediate elbow mobilization after distal biceps tendon repair carry the risk of wound breakdown, failure of repair, or patient dissatisfaction?

    PubMed

    Smith, James R A; Amirfeyz, Rouin

    2016-05-01

    Rehabilitation protocols after distal biceps repair are highly variable, with many surgeons favoring at least 2 weeks of immobilization. Is this conservative approach necessary to protect the repair? This was a consecutive series of 22 distal biceps tendon repairs in which a cortical button system was used. Patients were encouraged to mobilize their elbow actively from the day of surgery. Physiotherapy commenced at 3 weeks, with strengthening exercises when full range of movement (ROM) was achieved. The primary outcome measured was the clinical integrity of the repaired tendon. Secondary outcomes comprised wound or nerve complication, elbow ROM, and patient-reported outcome measures (the 11-item version of the Disabilities of Arm, Shoulder and Hand, Mayo Elbow Performance Index, and Oxford Elbow Score). All patients were male, and the dominant arm was repaired in 60%. Mean age was 40.6 years (range, 27-62 years), and mean time to surgery was 17 days (range, 5-99 days). Mean follow-up was 16.6 months (range, 3.8-29 months). All tendons were clinically intact at time of review. No wound breakdown occurred. Mean extension was -6° (range, -10° to 10°), and flexion was 144° (range, 135°-150°). All patients achieved full pronosupination. ROM was equivalent to the uninjured arm (P = .7). The mean 11-item version of the Disabilities of Arm, Shoulder and Hand score was 2.7 (range, 0-15.9), the Mayo Elbow Performance Index was 97.8 (range, 70-100), and the Oxford Elbow Score was 46.9 (range, 43-48) at the latest follow-up. One-third of patients experienced a transient sensory neurapraxia. Immediate mobilization after biceps tendon repair with a cortical button is possible, and in this series was not associated with failure of the repair, wound breakdown, or patient dissatisfaction. However, this series emphasizes the high incidence of nerve complication that can be associated with the single transverse incision technique. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Motion-plane dependency of the range of dart throw motion and the effects of tendon action due to finger extrinsic muscles during the motion.

    PubMed

    Mitsukane, Masahiro; Sekiya, Noboru; Kamono, Arinori; Nakabo, Tohru

    2018-03-01

    [Purpose] To clarify the motion-plane dependency of the range of dart throw motion and the effects of tendon action due to long finger flexors and extensors during the motion. [Subjects and Methods] Forty healthy subjects attended the experiment, and the active range of wrist motion in seven motion planes was measured with an originally designed apparatus. [Results] The reliability of the measurement was acceptable. The range of dart throw motion depended on the motion planes, with a maximum at around the motion plane of 45° from the sagittal plane (45° of pronation). The tendon action of long finger muscles was shown in dart throw motion except in 45° of pronation. [Conclusion] Motion-plane dependency of the range of dart throw motion exists in healthy subjects. The absence of tendon action due to finger extrinsic muscles in dart throw motion at 45° might be one of the causes of the advantage of dart throw motion.

  17. Genomic and lipidomic actions of nandrolone on detached rotator cuff muscle in sheep.

    PubMed

    Flück, Martin; Ruoss, Severin; Möhl, Christoph B; Valdivieso, Paola; Benn, Mario C; von Rechenberg, Brigitte; Laczko, Endre; Hu, Junmin; Wieser, Karl; Meyer, Dominik C; Gerber, Christian

    2017-01-01

    Reversal of fatty infiltration of pennate rotator cuff muscle after tendon release is hitherto impossible. The administration of nandrolone starting at the time of tendon release prevents the increase in fat content, but does not revert established fatty infiltration. We hypothesised that tendon release and myotendinous retraction cause alterations in lipid related gene expression leading to fatty muscle infiltration, which can be suppressed by nandrolone through its genomic actions if applied immediately after tendon release. The effects of infraspinatus tendon release and subsequent tendon repair at 16 weeks were studied in six Swiss Alpine sheep. In the interventional groups, 150mg nandrolone was administered weekly after tendon release until sacrifice (N22W, n=6) or starting at the time of repair (N6W, n=6). Infraspinatus volume, composition, expressed transcripts, lipids, and selected proteins were analyzed at baseline, 16 and 22 weeks. Tendon release reduced infraspinatus volume by 22% and increased fat content from 11% to 38%. These changes were not affected by repair. Fatty infiltration was associated with up-regulation of 227 lipid species, and increased levels of the adipocyte differentiation marker PPARG2 (peroxisome proliferator-activated receptor gamma 2). Nandrolone abrogated lipid accumulation, halved the loss in fiber area percentage, and up-regulated androgen receptor levels and transcript expression in the N22W but not the N6W group. The results document that nandrolone mitigates muscle-to-fat transformation after tendon release via a general down-regulation of lipid accumulation concomitantly with up-regulated expression of its nuclear receptor and downstream transcripts in skeletal muscle. Reduced responsiveness of retracted muscle to nandrolone as observed in the N6W group is reflected by a down-regulated transcript response. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Fos Promotes Early Stage Teno-Lineage Differentiation of Tendon Stem/Progenitor Cells in Tendon.

    PubMed

    Chen, Jialin; Zhang, Erchen; Zhang, Wei; Liu, Zeyu; Lu, Ping; Zhu, Ting; Yin, Zi; Backman, Ludvig J; Liu, Huanhuan; Chen, Xiao; Ouyang, Hongwei

    2017-11-01

    Stem cells have been widely used in tendon tissue engineering. The lack of refined and controlled differentiation strategy hampers the tendon repair and regeneration. This study aimed to find new effective differentiation factors for stepwise tenogenic differentiation. By microarray screening, the transcript factor Fos was found to be expressed in significantly higher amounts in postnatal Achilles tendon tissue derived from 1 day as compared with 7-days-old rats. It was further confirmed that expression of Fos decreased with time in postnatal rat Achilles tendon, which was accompanied with the decreased expression of multiply tendon markers. The expression of Fos also declined during regular in vitro cell culture, which corresponded to the loss of tendon phenotype. In a cell-sheet and a three-dimensional cell culture model, the expression of Fos was upregulated as compared with in regular cell culture, together with the recovery of tendon phenotype. In addition, significant higher expression of tendon markers was found in Fos-overexpressed tendon stem/progenitor cells (TSPCs), and Fos knock-down gave opposite results. In situ rat tendon repair experiments found more normal tendon-like tissue formed and higher tendon markers expression at 4 weeks postimplantation of Fos-overexpressed TSPCs derived nonscaffold engineering tendon (cell-sheet), as compared with the control group. This study identifies Fos as a new marker and functional driver in the early stage teno-lineage differentiation of tendon, which paves the way for effective stepwise tendon differentiation and future tendon regeneration. Stem Cells Translational Medicine 2017;6:2009-2019. © 2017 The Authors Stem Cells Translational Medicine published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.

  19. Arthroscopic Removal and Rotator Cuff Repair Without Acromioplasty for the Treatment of Symptomatic Calcifying Tendinitis of the Supraspinatus Tendon.

    PubMed

    Ranalletta, Maximiliano; Rossi, Luciano Andrés; Bongiovanni, Santiago Luis; Tanoira, Ignacio; Piuzzi, Nicolas; Maignon, Gastón

    2015-04-01

    Calcified rotator cuff tendinitis is a common cause of chronic shoulder pain that leads to significant pain and functional limitations. Although most patients respond well to conservative treatment, some eventually require surgical treatment. To evaluate the clinical outcome with arthroscopic removal of calcific deposit and rotator cuff repair without acromioplasty for the treatment of calcific tendinitis of the supraspinatus tendon. Case series; Level of evidence, 4. This study retrospectively evaluated 30 consecutive patients with a mean age of 49.2 years. The mean follow-up was 35 months (range, 24-88 months). Pre- and postoperative functional assessment was performed using the Constant score, University of California Los Angeles (UCLA) score, and Quick Disabilities of the Arm, Shoulder, and Hand (DASH). Pain was assessed by visual analog scale (VAS). Radiographs and magnetic resonance imaging (MRI) were performed to evaluate the recurrence of calcifications and the indemnity of the supraspinatus tendon repair. Significant improvement was obtained for pain (mean VAS, 8.7 before surgery to 0.8 after; P < .001). The mean Constant score increased from 23.9 preoperatively to 85.3 postoperatively (P < .001), the mean Quick DASH score decreased from 47.3 preoperatively to 8.97 postoperatively (P < .001), and the UCLA score increased from 15.8 preoperatively to 32.2 postoperatively (P < .001). MRI examination at last follow-up (70% of patients) showed no tendon tears, and 96.2% of patients were satisfied with their results. Arthroscopic removal and rotator cuff repair without acromioplasty can lead to good results in patients with symptomatic calcifying tendonitis of the supraspinatus tendon.

  20. 70° frontal visualization of lateral compartment of the elbow allows extensor carpi radialis brevis tendon release with preservation of the radial lateral collateral ligament.

    PubMed

    Arrigoni, Paolo; Fossati, Chiara; Zottarelli, Leonardo; Brady, Paul C; Cabitza, Paolo; Randelli, Pietro

    2014-01-01

    To determine whether the radial component of the lateral collateral ligament (R-LCL) and extensor carpi radialis brevis (ECRB) are consistently visible, using a 70° arthroscope, as parallel structures in the extra-articular space of the elbow, and to evaluate the clinical outcomes of these techniques in a series of patients. An arthroscopic ECRB tendon release was performed between 2008 and 2010. Eighteen patients were retrospectively evaluated at a minimum of 24 months' follow-up. The surgeon performed the ECRB release while protecting the R-LCL and viewing the structures extra-articularly with a 70° arthroscope through the anteromedial portal. Patients underwent surgery if they presented with localized tenderness and pain not responding to conservative treatment for 12 months and had magnetic resonance imaging scans indicating tendinopathy or degeneration. Arthritis, posterolateral rotatory instability, trauma, and previous surgeries were exclusion criteria. Intraoperative videos were reviewed and a clinical examination was performed by an independent reviewer at 24 months postoperatively. Patients were also evaluated with the Mayo Elbow Performance Score; Andrews-Carson score; and shortened Disabilities of the Arm, Shoulder and Hand questionnaire. Direct varus stress was applied in extension and flexion (40°), and the posterolateral pivot-shift and chair tests were performed. Visualization with the 70° arthroscope through the anteromedial portal was successful in all of the cases (100%). Visualization of the residual ECRB tendon stump, as well as the posterior common extensor tendon, was also achieved 94% of the time. The final mean Mayo Elbow Performance Score and Andrews-Carson score were 82.5 (range, 60 to 100) and 185.3 (range, 125 to 200), respectively. The mean postoperative score on the shortened Disabilities of the Arm, Shoulder and Hand questionnaire was 20.14 (range, 5 to 57.5). Clinical tests showed stability in all the cases. The 70° arthroscope allows visualization of the ECRB insertion and R-LCL frontally and in parallel. A surgical plane could be created between the structures. The clinical outcome was good or excellent in 78% of the cases. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Factors affecting healing rates after arthroscopic double-row rotator cuff repair.

    PubMed

    Tashjian, Robert Z; Hollins, Anthony M; Kim, Hyun-Min; Teefey, Sharlene A; Middleton, William D; Steger-May, Karen; Galatz, Leesa M; Yamaguchi, Ken

    2010-12-01

    Double-row arthroscopic rotator cuff repairs were developed to improve initial biomechanical strength of repairs to improve healing rates. Despite biomechanical improvements, failure of healing remains a clinical problem. To evaluate the anatomical results after double-row arthroscopic rotator cuff repair with ultrasound to determine postoperative repair integrity and the effect of various factors on tendon healing. Case series; Level of evidence, 4. Forty-eight patients (49 shoulders) who had a complete arthroscopic rotator cuff repair (double-row technique) were evaluated with ultrasound at a minimum of 6 months after surgery. Outcome was evaluated at a minimum of 1-year follow-up with standardized history and physical examination, visual analog scale for pain, active forward elevation, and preoperative and postoperative shoulder scores according to the system of the American Shoulder and Elbow Surgeons and the Simple Shoulder Test. Quantitative strength was measured postoperatively. Ultrasound and physical examinations were performed at a minimum of 6 months after surgery (mean, 16 months; range, 6 to 36 months) and outcome questionnaire evaluations at a minimum of 12 months after surgery (mean, 29 months; range, 12 to 55 months). Of 49 repairs, 25 (51%) were healed. Healing rates were 67% in single-tendon tears (16 of 24 shoulders) and 36% in multitendon tears (9 of 25 shoulders). Older age and longer duration of follow-up were correlated with poorer tendon healing (P < .03). Visual analog scale for pain, active forward elevation, American Shoulder and Elbow Surgeons scores, and Simple Shoulder Test scores all had significant improvement from baseline after repair (P < .0001). Increased age and longer duration of follow-up were associated with lower healing rates after double-row rotator cuff repair. The biological limitation at the repair site, as reflected by the effects of age on healing, appears to be the most important factor influencing tendon healing, even after maximizing repair biomechanical strength with a double-row construct.

  2. [Clinical application of peroneal muscles tendon transposition in repair of Achilles tendon rupture].

    PubMed

    Jin, Rihao; Jin, Yu; Fang, Xiulin

    2006-07-01

    To discuss applied anatomy, biomechanics and surgical procedures of long peroneal muscles tendon transposition in repair of occlusive achilles tendon rupture. The blood supply and the morphology of long peroneal muscles tendon were observed in the lower extremity of 50 sides adult specimens and the mechanical tests which stretch load on the tendon were carried out. The methods were designed on the basis of the anatomical characteristics and morphology. Ten patients suffering occlusive Achilles tendon rupture were treated by using long peroneal muscles tendon transposition from March 2001 to July 2004. Among 10 patients, there were 7 males and 3 females, aging 32 to 54 years including 6 cases of jump injury, 2 cases of bruise, 1 case of step vacancy and 1 case of spontaneity injury. The interval between injury and surgery was 6 hours to 7 days in 7 fresh rupture and 21 days to 3 months in 3 old rupture. All cases belonged to occlusive Achilles tendon rupture (8 cases of complete rupture and 2 cases of incomplete rupture). The origin of long peroneal muscles was proximal tibia and fibular head, the end of them was base of first metatarsal bones and medial cuboid. The length of tendon was 13.5 +/- 2.5 cm. The width of origin tendon was 0.9 +/- 0.2 cm and the thickness was 0.3 +/- 0.1 cm; the width on apex of lateral malleolus was 0.7 +/- 0.1 cm and the thickness was 0.4 +/- 0.1 cm, the width on head of cuboid was 0.7 +/- 0.1 cm and the thickness was 0.3 +/- 0.1 cm. The long peroneal muscles tendon had abundant blood supply. The results of mechanical test showed that the biggest load was 2,292.4 +/- 617.3 N on tendon calcaneus, 1,020.4 +/- 175.4 N on long peroneal muscles tendon, 752.0 +/- 165.4 N on peroneus brevis tendon and 938.2 +/- 216.7 N on tibialis posterior tendon. Ten cases of occlusive Achilles tendon rupture achieved healing by first intention and were followed up 18-24 months. No Achilles tendon re-rupture, necrosis of skin or other complications occurred. According to Amerind-holm criterion for curative results, the results were excellent in 7 cases and good in 3 cases and the excellent and good rate was 100%. The long peroneal muscles tendon transposition is a perfect and simple way to repair occlusive Achilles tendon rupture.

  3. [Musculature of the pelvic limb of the American weasel (Mustela nigripes, Audubon and Bachman)].

    PubMed

    Bisaillon, A

    1976-01-01

    The origins and insertions of the muscles of the pelvic limb of the black-footed ferret (Mustela nigripes) are illustrated and described. The results based on the dissection of two adult specimens are compared with those of other investigations on the myology of the Mustelids. The musculature of the pelvic limb of Mustela nigripes is substantially similar to that of other Mustelids investigated except for slight differences of individual muscles. The most obvious differences involve the tendons of the mm. fibularis longus, fibularis brevis and extensor digitalis lateralis. The tendon of the m. fibularis longus contains a small sesamoid bone.

  4. Rupture of the extensor hood of the fifth toe: a rare injury.

    PubMed

    Venturini, Sara; Gaba, Suchi; Mangwani, Jitendra

    2017-02-27

    Closed injuries of the extensor hood of the lesser toes are rare and seldom reported in the literature. We present the case of a woman aged 25 years who presented to the orthopaedic fracture clinic with a 2-week history of pain in the left fifth toe and inability to extend following a ballet dancing session. Investigations showed no fracture on plain radiographs, but an ultrasound scan demonstrated rupture to the extensor hood of the little toe. Successful surgical repair of the extensor hood was performed, and the patient made a good recovery with return to dancing activities. 2017 BMJ Publishing Group Ltd.

  5. The "Parachute" Technique: A Simple and Effective Single-Row Procedure to Achieve an Increased Contact Area Between the Cuff-Tendon and Its Footprint.

    PubMed

    Natera, Luis; Consigliere, Paolo; Witney-Lagen, Caroline; Brugera, Juan; Sforza, Giuseppe; Atoun, Ehud; Levy, Ofer

    2017-10-01

    Many techniques of arthroscopic rotator cuff repair have been described. No significant differences in clinical outcomes or rerupture rates have been observed when comparing single-row with double-row methods. Not all single- and double-row repairs are the same. The details of the technique used are crucial. It has been shown that the suture-tendon interface is the weakest point of the reconstruction. Therefore, the biomechanical properties of rotator cuff repairs might be influenced more by the suture configuration than by the number of anchors or by the number of rows involved. Techniques that secure less amount of tendon over a smaller area of the healing zone might be expected to have higher failure rates. The way the sutures of the "parachute technique" are configured represents a quadruple mattress that increases the contact and pressure between the tendon and its footprint and increases the primary load to failure of the repair. We present a simple and effective single-row technique that involves the biomechanical and biological advantages related to the increased contact area and pressure between the cuff and its footprint.

  6. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons

    PubMed Central

    Thorpe, Chavaunne T.; Godinho, Marta S.C.; Riley, Graham P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R.C.

    2015-01-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. PMID:25958330

  7. Load response and gap formation in a single-row cruciate suture rotator cuff repair.

    PubMed

    Huntington, Lachlan; Richardson, Martin; Sobol, Tony; Caldow, Jonathon; Ackland, David C

    2017-06-01

    Double-row rotator cuff tendon repair techniques may provide superior contact area and strength compared with single-row repairs, but are associated with higher material expenses and prolonged operating time. The purpose of this study was to evaluate gap formation, ultimate tensile strength and stiffness of a single-row cruciate suture rotator cuff repair construct, and to compare these results with those of the Mason-Allen and SutureBridge repair constructs. Infraspinatus tendons from 24 spring lamb shoulders were harvested and allocated to cruciate suture, Mason-Allen and SutureBridge repair groups. Specimens were loaded cyclically between 10 and 62 N for 200 cycles, and gap formation simultaneously measured using a high-speed digital camera. Specimens were then loaded in uniaxial tension to failure, and construct stiffness and repair strength were evaluated. Gap formation in the cruciate suture repair was significantly lower than that of the Mason-Allen repair (mean difference = 0.6 mm, P = 0.009) and no different from that of the SutureBridge repair (P > 0.05). Both the cruciate suture repair (mean difference = 15.7 N/mm, P = 0.002) and SutureBridge repair (mean difference = 15.8 N/mm, P = 0.034) were significantly stiffer than that of the Mason-Allen repair; however, no significant differences in ultimate tensile strength between repair groups were discerned (P > 0.05). The cruciate suture repair construct, which may represent a simple and cost-effective alternative to double-row and double-row equivalent rotator cuff repairs, has comparable biomechanical strength and integrity with that of the SutureBridge repair, and may result in improved construct longevity and tendon healing compared with the Mason-Allen repair. © 2017 Royal Australasian College of Surgeons.

  8. Cellular response of healing tissue to DegraPol tube implantation in rabbit Achilles tendon rupture repair: an in vivo histomorphometric study.

    PubMed

    Buschmann, Johanna; Meier-Bürgisser, Gabriella; Bonavoglia, Eliana; Neuenschwander, Peter; Milleret, Vincent; Giovanoli, Pietro; Calcagni, Maurizio

    2013-05-01

    In tendon rupture repair, improvements such as higher primary repair strength, anti-adhesion and accelerated healing are needed. We developed a potential carrier system of an electrospun DegraPol tube, which was tightly implanted around a transected and conventionally sutured rabbit Achilles tendon. Histomorphometric analysis of the tendon tissue 12 weeks postoperation showed that the tenocyte density, tenocyte morphology and number of inflammation zones were statistically equivalent, whether or not DegraPol tube was implanted; only the collagen fibres were slightly less parallelly orientated in the tube-treated case. Comparison of rabbits that were operated on both hind legs with ones that were operated on only one hind leg showed that there were significantly more inflammation zones in the two-leg cases compared to the one-leg cases, while the implantation of a DegraPol tube had no such adverse effects. These findings are a prerequisite for using DegraPol tube as a carrier system for growth factors, cytokines or stem cells in order to accelerate the healing process of tendon tissue. Copyright © 2012 John Wiley & Sons, Ltd.

  9. Acute traumatic rupture of the patellar tendon in pediatric population: Case series and review of the literature.

    PubMed

    Ali Yousef, Mohamed Abdelhamid; Rosenfeld, Scott

    2017-11-01

    Intact knee extensor mechanism is required for the normal function of the lower extremity. Patellar tendon rupture is a relatively rare injury with peak age incidence around 40 years and usually occurs midsubstance. The occurrence of pure patellar tendon rupture without bony avulsion is an extremely rare injury in the pediatric population with few cases reported in the literature with limited information regarding frequency, complications, and outcomes in children. However, due to increased participation in sports and high-energy recreational activities during childhood, the frequency of such injuries has progressively increased. To evaluate the frequency of pediatric patellar tendon rupture injuries and describe the radiological findings, treatment modalities, and outcome of such injuries. Demographic and clinical data on a series of patients who sustained patellar tendon rupture were reviewed. These data included age at time of injury, sex, laterality, mechanism of injury, associated injuries, complications, presence or absence of Osgood-Schlatter disease, diagnostic imaging such as plain radiographs and magnetic resonance images (MRI), surgical technique, method of fixation, period of postoperative immobilization, total duration of physiotherapy, time to return to sports activities and follow-up duration. Insall-Salvati ratio was calculated on the preoperative lateral x-ray. The functional outcome was evaluated with regard to final knee active range of motion (AROM), manual quadriceps muscle testing, and presence or the absence of terminal extension lag. Clinical outcome rating using knee society score (KSS) was performed and functional outcome was further classified according to the calculated score. Five male patients with patellar tendon rupture (7%) were identified among 71 pediatric patients who sustained acute traumatic injury of the knee extensor mechanism. The mean age at the time of injury was 13.6 years (range: 12-15 years). The injury occurred in relation to sports activities in 4 patients. Osteogenesis imperfecta and Osgood-Schlatter disease were identified in 2 patients. High riding patella is the hallmark diagnostic sign detected in plain x-ray with preoperative Insall-Salvati ratio ranged from 1.7 to 2.5. Three patients had pure soft tissue avulsion distally from the proximal tibia, 1 patient had pure soft tissue avulsion proximally from the inferior patellar pole, and 1 patient with midsubstance tendinous disruption. No associated intra-articular lesions were identified. Suture bridge double row technique, transpatellar suturing, and transosseous suturing through the proximal tibia were used for patellar tendon reinsertion. After a mean follow-up period of 18. 4 weeks (range: 10-30 weeks), patients achieved AROM ranging from 0 to 120° to 0-137° without terminal extension lag. The mean time to return to sports activity was 22 weeks (range: 13-30 weeks). Quadriceps muscle strength was 5/5 at the final follow-up visit in all patients; however, relative muscle atrophy was noted in comparison to the other side in one patient. The mean KSS was 91.8 points (range: 79-100 points) with excellent outcome in 4 patients and good outcome in 1 patient. Patellar tendon rupture is rare in the pediatric population and represents 7% of pediatric patients who sustained acute traumatic injury of the knee extensor mechanism. Ruptures may occur midsubstance, or from proximal or distal insertions. High riding patella is the hallmark diagnostic sign for such injury. Although rare, it is considered a serious injury that necessitates early diagnosis and surgical intervention. Functional range of motion was obtained in all patients with different modalities of treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Effect of Micro-RNA on Tenocytes and Tendon-Related Gene Expression: A Systematic Review.

    PubMed

    Dubin, Jeremy A; Greenberg, Daniel R; Iglinski-Benjamin, Kag C; Abrams, Geoffrey D

    2018-06-06

    The purpose of the review was to synthesize the current literature regarding the effect of miRNA on biological processes known to be involved in tendon and tenocyte development and homeostasis. Using multiple databases, a systematic review was performed with a customized search term crafted to identify any study examining micro-RNA in relation to tendon and/or tenocytes. Results were classified based on the following categories: gene expression, tenocyte development and differentiation, tendon tissue repair, and tenocyte senescence. A total of 3,112 potentially relevant studies were reviewed, and after exclusion criteria was applied, 15 investigations were included in the final analysis. There were 14 specific miRNA included in this review, with 11 studies reporting on tendon-related gene expression, five reporting on tendon development and/or tenocyte differentiation, six reporting on tendon tissue repair, and five reporting on tenocyte senescence. The miR-29 family was the most commonly reported micro-RNA in the investigation. We also report on a number of micro-RNA which are associated with both positive and negative effects on tendon homeostasis. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. Isolated avulsion of the vastus lateralis tendon insertion in a weightlifter: a case report

    PubMed Central

    Trikha, Paul S; Wood, David G

    2009-01-01

    Introduction We report a case of isolated, unilateral avulsion of the vastus lateralis tendon from its insertion at the patella. This was diagnosed by magnetic resonance imaging, and underwent successful surgical repair. Case presentation A healthy 32-year-old national level power lifter presented with an isolated avulsion of the vastus lateralis tendon. After a failed course of conservative therapy he underwent surgical repair and a graded physical therapy programme. One year later he returned to full training with no evidence of re-rupture. Conclusion This is the first reported case of an isolated vastus lateralis avulsion. Our experience suggests that magnetic resonance imaging is invaluable in the diagnosis of this condition and that surgical repair provides a good outcome in high demand patients. PMID:19918436

  12. Surgical treatment of partial biceps tendon ruptures at the elbow.

    PubMed

    Dellaero, David T; Mallon, William J

    2006-01-01

    We present the treatment and results of a consecutive series of 7 patients (mean age, 42.7 years) with partial ruptures of the distal biceps tendon. All injuries occurred as the result of either heavy labor or weightlifting. Diagnosis in all cases was made with magnetic resonance imaging. After failure of conservative therapy, the patients were treated with repair of the distal biceps tendon. Mean follow-up was 30.6 months (range, 25-39 months). Results were uniformly good, with all patients satisfied with the outcome. All patients maintained their preoperative range of motion, with none reporting significant postoperative pain. The only complication was transient neurapraxias of the lateral antebrachial cutaneous nerve in 2 cases. We conclude that patients presenting with chronic pain in the cubital fossa should be evaluated for possible partial biceps tendon tear. If the diagnosis of partial tendon tear is made, surgical repair is a safe and effective method of treatment.

  13. Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

    PubMed

    Pauly, Stephan; Gerhardt, Christian; Chen, Jianhai; Scheibel, Markus

    2010-12-01

    Several techniques for arthroscopic repair of rotator cuff defects have been introduced over the past years. Besides established techniques such as single-row repairs, new techniques such as double-row reconstructions have gained increasing interest. The present article therefore provides an overview of the currently available literature on both repair techniques with respect to several anatomical, biomechanical, clinical and structural endpoints. Systematic literature review of biomechanical, clinical and radiographic studies investigating or comparing single- and double-row techniques. These results were evaluated and compared to provide an overview on benefits and drawbacks of the respective repair type. Reconstructions of the tendon-to-bone unit for full-thickness tears in either single- or double-row technique differ with respect to several endpoints. Double-row repair techniques provide more anatomical reconstructions of the footprint and superior initial biomechanical characteristics when compared to single-row repair. With regard to clinical results, no significant differences were found while radiological data suggest a better structural tendon integrity following double-row fixation. Presently published clinical studies cannot emphasize a clearly superior technique at this time. Available biomechanical studies are in favour of double-row repair. Radiographic studies suggest a beneficial effect of double-row reconstruction on structural integrity of the reattached tendon or reduced recurrent defect rates, respectively.

  14. Biomechanical validation of load-sharing rip-stop fixation for the repair of tissue-deficient rotator cuff tears.

    PubMed

    Burkhart, Stephen S; Denard, Patrick J; Konicek, John; Hanypsiak, Bryan T

    2014-02-01

    Poor-quality tendon is one of the most difficult problems the surgeon must overcome in achieving secure fixation during rotator cuff repair. A load-sharing rip-stop construct (LSRS) has recently been proposed as a method for improving fixation strength, but the biomechanical properties of this construct have not yet been examined. To compare the strength of the LSRS construct to that of single-row fixation for rotator cuff repair. Controlled laboratory study. Rotator cuff tears were created in 6 cadaveric matched-pair specimens and repaired with a single row or an LSRS. In the LSRS repair, a 2-mm suture tape was placed as an inverted mattress stitch in the rotator cuff, and sutures from 2 anchors were placed as simple stitches that passed medial to the suture tape. The suture tape limbs were secured with knotless anchors laterally before sutures were tied from the medial anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 371 ± 102 N in single-row repairs compared with 616 ± 185 N in LSRS repairs (P = .031). There was no difference in displacement with cyclic loading between the groups (3.3 ± 0.8 mm vs. 3.5 ± 1.1 mm; P = .561). In the single-row group, 4 of 6 failures occurred at the suture-tendon interface. In the LSRS group, only 1 failure occurred at the suture-tendon interface. The ultimate failure load of the LSRS construct for rotator cuff repair was 1.7 times that of a single-row construct in a cadaveric model. The LSRS rotator cuff repair construct may be useful in the repair of difficult tears such as massive tears, medial tears, and tears with tendon loss.

  15. Arthroscopic Repair of Massive Cuff Tears With Large Subscapularis Tendon Ruptures (Lafosse III/IV): A Prospective Magnetic Resonance Imaging-Controlled Case Series of 26 Cases With a Minimum Follow-up of 1 Year.

    PubMed

    Grueninger, Patrick; Nikolic, Nikola; Schneider, Joerg; Lattmann, Thomas; Platz, Andreas; Chmiel, Corinne; Meier, Christoph

    2015-11-01

    To prospectively assess arthroscopic repair of massive cuff tears (MCT) in a highly selective patient group with large subscapularis (SSC) tendon tears by means of clinical results and magnetic resonance imaging (MRI) studies. Between April 2009 and December 2010, 26 patients with MCT were treated with arthroscopic rotator cuff repair. Only lesions involving a large tear of the SSC tendon (Lafosse III or IV) in combination with a complete tear of the supraspinatus (SSP) tendon and a tear of at least the anterior third of the infraspinatus (ISP) tendon were included. Minimum follow-up was 1 year. Pre- and postoperative assessment included a standardized clinical examination, subjective patient outcome, and MRI (structural integrity, fatty muscle infiltration, and muscular mass). Mean follow-up was 17 months (range, 12 to 34 months). MRI was performed in 25 patients. In 21 (84%) the cuff repair was intact. A partial retear of the SSC was found in 2 patients (8%). In 2 patients (8%) a full-thickness retear of the posterosuperior cuff was observed (1 SSP, 1 SSP/ISP). A significant increase of the muscle mass and decrease of fatty infiltration was observed for the SSC and SSP but not for the ISP. The mean Constant-Murley score improved from 36 to 86 points (P < .001) with all its subscores as well (P < .001). Muscular strength improved for the SSC (4.9 v 3.0, P < .001), SSP (4.6 v 2.9, P < .001), and ISP (4.8 v 3.4, P < .001). Overall patient satisfaction was high (3.6 ± 0.8). Arthroscopic repair of MCT involving the ISP, SSP, and large tears of the SSC provides a reliable tendon healing, in particular for the SSC tendon, combined with good functional results. Level IV, therapeutic case series. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. In situ repair of partial articular surface lesions of the supraspinatus tendon.

    PubMed

    Paim, Arildo Eustáquio

    2017-01-01

    To demonstrate the in situ repair technique of high-degree partial-thickness articular surface lesions of the supraspinatus tendon (SS). The procedure consists of the arthroscopic surgical repair of these lesions, without the need to complete the lesion, as occurs in traditional classical technique. A small incision is made in the longitudinal direction of the intact bursal fibers and where bone fixation anchors are introduced, which makes the procedure easier. These anchors are transferred to the tendon and thus enable the repair of the lesion. 48 shoulders were operated in the period 2010-2015. The minimum follow-up was 12 months and maximum 60 months. Ages ranged from 38 years to 75 years (mean 54 years). They were indicated for the repair of high-degree symptomatic lesions and at least 30% intact superior bursal fibers of good quality. Patients were evaluated according to the UCLA criteria, the results were: 69% excellent, 17% good, 7% fair, and 7% poor. Fair results occurred in three patients with associated symptoms of polyarthralgia who remained with residual pain. Three patients developed postoperative joint stiffness (7%). The procedure under study is safe and easy to reproduce. It shows high rates of positive results (86%). The opening made in the bursal side of the SS tendon allowed the arthroscope to remain in the subacromial space, making it easier to perform surgery.

  17. Current Status of Tissue-Engineered Scaffolds for Rotator Cuff Repair.

    PubMed

    Chainani, Abby; Little, Dianne

    2016-06-01

    Rotator cuff tears continue to be at significant risk for re-tear or for failure to heal after surgical repair despite the use of a variety of surgical techniques and augmentation devices. Therefore, there is a need for functionalized scaffold strategies to provide sustained mechanical augmentation during the critical first 12-weeks following repair, and to enhance the healing potential of the repaired tendon and tendon-bone interface. Tissue engineered approaches that combine the use of scaffolds, cells, and bioactive molecules towards promising new solutions for rotator cuff repair are reviewed. The ideal scaffold should have adequate initial mechanical properties, be slowly degrading or non-degradable, have non-toxic degradation products, enhance cell growth, infiltration and differentiation, promote regeneration of the tendon-bone interface, be biocompatible and have excellent suture retention and handling properties. Scaffolds that closely match the inhomogeneity and non-linearity of the native rotator cuff may significantly advance the field. While substantial pre-clinical work remains to be done, continued progress in overcoming current tissue engineering challenges should allow for successful clinical translation.

  18. Current Status of Tissue-Engineered Scaffolds for Rotator Cuff Repair

    PubMed Central

    Chainani, Abby; Little, Dianne

    2015-01-01

    Rotator cuff tears continue to be at significant risk for re-tear or for failure to heal after surgical repair despite the use of a variety of surgical techniques and augmentation devices. Therefore, there is a need for functionalized scaffold strategies to provide sustained mechanical augmentation during the critical first 12-weeks following repair, and to enhance the healing potential of the repaired tendon and tendon-bone interface. Tissue engineered approaches that combine the use of scaffolds, cells, and bioactive molecules towards promising new solutions for rotator cuff repair are reviewed. The ideal scaffold should have adequate initial mechanical properties, be slowly degrading or non-degradable, have non-toxic degradation products, enhance cell growth, infiltration and differentiation, promote regeneration of the tendon-bone interface, be biocompatible and have excellent suture retention and handling properties. Scaffolds that closely match the inhomogeneity and non-linearity of the native rotator cuff may significantly advance the field. While substantial pre-clinical work remains to be done, continued progress in overcoming current tissue engineering challenges should allow for successful clinical translation. PMID:27346922

  19. Efficacy of supraspinatus tendon repair using mesenchymal stem cells along with a collagen I scaffold.

    PubMed

    Tornero-Esteban, Pilar; Hoyas, José Antonio; Villafuertes, Esther; Rodríguez-Bobada, Cruz; López-Gordillo, Yamila; Rojo, Francisco J; Guinea, Gustavo V; Paleczny, Anna; Lópiz-Morales, Yaiza; Rodriguez-Rodriguez, Luis; Marco, Fernando; Fernández-Gutiérrez, Benjamín

    2015-08-14

    Our main objective was to biologically improve rotator cuff healing in an elderly rat model using mesenchymal stem cells (MSCs) in combination with a collagen membrane and compared against other current techniques. A chronic rotator cuff tear injury model was developed by unilaterally detaching the supraspinatus (SP) tendons of Sprague-Dawley rats. At 1 month postinjury, the tears were repaired using one of the following techniques: (a) classical surgery using sutures (n = 12), (b) type I collagen membranes (n = 15), and (c) type I collagen membranes + 1 × 106 allogeneic MSCs (n = 14). Lesion restoration was evaluated at 1, 2, and 3 months postinjury based on biomechanical criteria. Continuous variables were described using mean and standard deviation (SD). To analyse the effect of the different surgical treatments in the repaired tendons' biomechanical capabilities (maximum load, stiffness, and deformity), a two-way ANOVA model was used, introducing an interaction between such factor and time (1, 2, and 3 months postinjury). With regard to maximum load, we observed an almost significant interaction between treatment and time (F = 2.62, df = 4, p = 0.053). When we analysed how this biomechanical capability changed with time for each treatment, we observed that repair with OrthADAPT and MSCs was associated with a significant increase in maximum load (p = 0.04) between months 1 and 3. On the other hand, when we compared the different treatments among themselves at different time points, we observed that the repair with OrthADAPT and MSCs has associated with a significant higher maximum load, when compared with the use of suture, but only at 3 months (p = 0.014). With regard to stiffness and deformity, no significant interaction was observed (F = 1.68, df = 4, p = 0.18; F = 0.40, df = 4, p = 0.81; respectively). The implantation of MSCs along with a collagen I scaffold into surgically created tendon defects is safe and effective. MSCs improved the tendon's maximum load over time, indicating that MSCs could help facilitate the dynamic process of tendon repair.

  20. A study of the anatomy and injection techniques of the ovine stifle by positive contrast arthrography, computed tomography arthrography and gross anatomical dissection.

    PubMed

    Vandeweerd, Jean-Michel; Kirschvink, Nathalie; Muylkens, Benoit; Depiereux, Eric; Clegg, Peter; Herteman, Nicolas; Lamberts, Matthieu; Bonnet, Pierre; Nisolle, Jean-Francois

    2012-08-01

    Although ovine stifle models are commonly used to study osteoarthritis, meniscal pathology and cruciate ligament injuries and repair, there is little information about the anatomy of the joint or techniques for synovial injections. The objectives of this study were to improve anatomical knowledge of the synovial cavities of the ovine knee and to compare intra-articular injection techniques. Synovial cavities of 24 cadaver hind limbs from 12 adult sheep were investigated by intra-articular resin, positive-contrast arthrography, computed tomography (CT) arthrography and gross anatomical dissection. Communication between femoro-patellar, medial femoro-tibial and lateral femoro-tibial compartments occurred in all cases. The knee joint should be considered as one synovial structure with three communicating compartments. Several unreported features were observed, including a communication between the medial femoro-tibial and lateral femoro-tibial compartments and a latero-caudal recess of the lateral femoro-tibial compartment. No intermeniscal ligament was identified. CT was able to define many anatomical features of the stifle, including the anatomy of the tendinous synovial recess on the lateral aspect of the proximal tibia under the combined tendon of the peroneus tertius, extensor longus digitorum and extensor digiti III proprius. An approach for intra-articular injection into this recess (the subtendinous technique) was assessed and compared with the retropatellar and paraligamentous techniques. All three injection procedures were equally successful, but the subtendinous technique appeared to be most appropriate for synoviocentesis and for injections in therapeutic research protocols with less risk of damaging the articular cartilage. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. The punctal apposition syndrome: a new surgical approach.

    PubMed

    Francis, I C; Wan, M K

    2002-11-01

    To assess the punctal apposition syndrome (PAS) and its response to lateral canthal tendon (LCT) repair. In this retrospective, interventional case series, five patients (seven symptomatic eyes) with PAS were managed. Lateral canthal tendon repair was performed in all seven eyes. The main outcome measure was correction of watery eye symptomatology. All five patients achieved symptomatic resolution. Conjunctivochalasis and functional nasolacrimal duct obstruction were associated with the PAS. This new surgical approach to the PAS, using a LCT repair, was successful in all patients. Two patients (three eyes) required conjunctivochalasis excision.

  2. Fetal derived embryonic-like stem cells improve healing in a large animal flexor tendonitis model

    PubMed Central

    2011-01-01

    Introduction Tendon injury is a common problem in athletes, with poor tissue regeneration and a high rate of re-injury. Stem cell therapy is an attractive treatment modality as it may induce tissue regeneration rather than tissue repair. Currently, there are no reports on the use of pluripotent cells in a large animal tendon model in vivo. We report the use of intra-lesional injection of male, fetal derived embryonic-like stem cells (fdESC) that express Oct-4, Nanog, SSEA4, Tra 1-60, Tra 1-81 and telomerase. Methods Tendon injury was induced using a collagenase gel-physical defect model in the mid-metacarpal region of the superficial digital flexor tendon (SDFT) of eight female adult Thoroughbred or Thoroughbred cross horses. Tendon lesions were treated one week later with intra-lesional injection of male derived fdESCs in media or media alone. Therapy was blinded and randomized. Serial ultrasound examinations were performed and final analysis at eight weeks included magnetic resonance imaging (MRI), biochemical assays (total DNA, glycosaminoglycan, collagen), gene expression (TNC, TNMD, SCX, COL1A1, COL3A1, COMP, DCN, MMP1, MMP3, MMP13, 18S) and histology. Differences between groups were assessed with Wilcoxon's rank sum test. Results Cell survival was demonstrated via the presence of the SRY gene in fdESC treated, but not control treated, female SDFT at the end of the trial. There were no differences in tendon matrix specific gene expression or total proteoglycan, collagen or DNA of tendon lesions between groups. Tissue architecture, tendon size, tendon lesion size, and tendon linear fiber pattern were significantly improved on histologic sections and ultrasound in the fdESC treated tendons. Conclusions Such profound structural effects lend further support to the notion that pluripotent stem cells can effect musculoskeletal regeneration, rather than repair, even without in vitro lineage specific differentiation. Further investigation into the safety of pluripotent cellular therapy as well as the mechanisms by which repair was improved seem warranted. PMID:21272343

  3. Musculoskeletal injuries in the ultramarathon: the 1990 Westfield Sydney to Melbourne run.

    PubMed Central

    Fallon, K E

    1996-01-01

    OBJECTIVE: To document the injuries sustained by participants in a 1005 km ultramarathon. METHODS: Clinical notes were reviewed on entrants in the 1005 km Sydney to Melbourne ultramarathon. An injury was recorded following self referral by a participant or if the history obtained from the runner or his support crew indicated the likelihood of a significant injury which could have an impact upon performance. RESULTS: 64 injuries were found in 32 runners. The knee (31.3%) and ankle (28.1%) regions were most commonly injured. The most common single diagnosis was retropatellar pain syndrome, and Achilles tendinitis and medial tibial stress syndrome were the next most common injuries. Peritendinitis/tendinitis of the tendons passing under the extensor retinaculum at the ankle, an injury infrequently reported in other sports, was common (19% of all injuries). CONCLUSIONS: The injuries were typically associated with running but 12 (19% of the total) involved the tendons of the muscles of the anterior compartment of the lower leg, and in almost every case the major site of inflammation was at the extensor retinaculum at the anterior aspect of the ankle. This injury appears to be relatively specific to the ultramarathon-"ultramarathoner's ankle". Images p321-a PMID:9015594

  4. Reconstruction of chronic achilles tendon rupture with the use of interposed tissue between the stumps.

    PubMed

    Yasuda, Toshito; Kinoshita, Mitsuo; Okuda, Ryuzo

    2007-04-01

    The gap between the tendon stumps in chronic Achilles tendon rupture has reportedly been filled with interposed scar tissue. In the authors' clinical experience, this interposed tissue is often thick and resists tension, so they considered it was possible to use the interposed tissue for reconstruction of Achilles tendon rupture. Scar tissue interposed between the tendon stumps has the capacity to form tendon-like repair tissue in patients with chronic Achilles tendon rupture. Case series; Level of evidence, 4. Six patients with chronic rupture of the Achilles tendon underwent tendon reconstruction with the use of interposed tissue between the stumps. The average time from the primary injury to surgery was 22 weeks (range, 9 to 30 weeks). Preoperative magnetic resonance imaging (MRI), histology of the interposed tissue, and clinical results were evaluated. The average postoperative follow-up period was 31 months (range, 24 to 43 months). Preoperative T2-weighted MRI in all cases revealed that chronically ruptured Achilles tendons were thickened and fusiform-shaped with diffuse intratendinous high-signal alterations throughout. Longitudinal high-signal bands were seen throughout the tendon, except at the musculotendinous junction and insertion on the calcaneus. Histologically, scar tissue interposed between the tendon stumps consisted of dense collagen fibers, and degenerative changes were not seen. After surgery, no patient had difficulty in walking or stair climbing, and all were able to perform a single-limb toe raise. The mean preoperative and postoperative American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scores were 88.2 and 98.3 points, respectively; the difference was statistically significant (P = .0277). Interposed tissue between the tendon stumps is suitable for repair of chronic Achilles tendon rupture if preoperative MRI shows a thickened fusiform-shaped Achilles tendon with diffuse intratendinous high-signal alterations throughout.

  5. Arthroscopic transtendinous repair of articular-sided pasta (partial articular supraspinatus tendon avulsion) injury.

    PubMed

    Wang, Yi; Lu, Liangyu; Lu, Zhe; Xiao, Lei; Kang, Yifan; Wang, Zimin

    2015-01-01

    To evaluate clinical efficacy of arthroscopic transtendinous repair of partial articular-sided PASTA (partial articular supraspinatus tendon avulsion) injury. From February 2011 to July 2014, 12 cases of PASTA, aged 29 to 72 years with an average of 52.9 ± 13.3 years, were treated arthoscopically. To repair PASTA, articular-sided rotator cuff tear was explored, injury site was punctured and labeled with PDS absorbable monofilament suture (Ethicon, Somerville, NJ, USA) suture, subacromial bursa was cleaned up with acromioplasty, and integrity of bursa-side rotator cuff was assessed. Then with arthroscope in glenohumeral joint, footprint of the bursa-side supraspinatus tendon was preserved, rivets were introduced into the joint through supraspinatus tendon, joint-side partial tear was sutured, and anatomical reconstruction of the rotator cuff footprint was established. The patients were followed up post-operatively for 12-36 months, average 22 ± 7.3 months. The clinical outcomes were emulated with ASES (American Shoulder and Elbow Surgeons) Shoulder Score system and UCLA (University of California at Los Angeles) Shoulder rating scale. The post-operative ASES score was 89.7 ± 5.6, higher than the pre-operative one 49.8 ± 9.8 (t = 12.25, P <0.0001). While UCLA scale increased from the pre-operative 17.3, ± 3.3 to the post-operative 30.4 ± 3.2 points (t = 9.87, P <0.0001), with a satisfaction rate of 11/12 (91.7%). Trans-tendon repair is ideal for PASTA with advantage of maximal preservation of the normal rotator cuff tissue, anatomical reconstruction of the rotator cuff footprint and stable fixation of tendon-bone interface.

  6. Isokinetic strength and endurance after percutaneous and open surgical repair of Achilles tendon ruptures.

    PubMed

    Goren, David; Ayalon, Moshe; Nyska, Meir

    2005-04-01

    Reports on complete spontaneous Achilles tendon ruptures and associated treatment have become more frequent in the literature in the past two decades, as has the request for treatments that enable the finest possible functional recovery. The best available treatment is a matter of considerable controversy in the literature. The purpose of this study was to compare the isokinetic strength and endurance of the plantarflexor muscle-tendon unit in subjects who sustained rupture of the Achilles tendon and underwent either open surgery or closed percutaneous repair of the Achilles tendon. Twenty patients (18 males, 2 females) with spontaneous ruptures of the Achilles tendon were included in this study. Ten patients were treated by open surgery, and 10 patients were treated percutaneously. All patients had ruptured their Achilles tendon more than 6 months before the study, and all of the ruptures occurred 3.5 years or less before the day of the testing. All patients underwent an oriented physical examination. An isokinetic Biodex dynamometer (Biodex Medical System, Shirley, NY) was used to measure ankle joint angle, and in plantarflexion to calculate the torque at the ankle joint (Newton/meter), and the average work (jouls) for both maximal power and endurance. Each measurement was compared to the normal ankle. Biodex dynamometer evaluations at 90 deg/sec demonstrated a significant difference of maximal voluntary plantarflexor torque, endurance performance and range of motion at the ankle joint between the involved and uninvolved sides in patients treated by either mode of treatment. Yet, no statistically significant differences were revealed for the parameters mentioned above between the subjects that were treated either percutaneously or by an open surgery. In functional terms, the biomechanical outcomes of open surgery and percutaneous repair for acute ruptures of the Achilles tendon are both effective.

  7. Arthroscopic trans-osseous rotator cuff repair

    PubMed Central

    Chillemi, Claudio; Mantovani, Matteo

    2017-01-01

    Summary Background: Mechanical factors are at the basis of any tendon healing process, being pressure an aspect able to positively influence it. For this reason transosseous rotator cuff repair represents the gold standard procedure for patients affected by a cuff tear, maximizing the tendon footprint contact area and reducing motion at the tendon to bone interface. Methods: The Authors present an all arthroscopic suture bridge-like transosseous repair with the preparation of a single transosseous tunnel perfor med thanks to a precise dedicated instrument (Compasso®) and one implant (Elite-SPK®) with the use of only 3 suture wires. In addition this technique permits to accurately prepare the bony side of the lesion without any risk or complication, such as anchor pull-out and greater tuberosity bone osteolysis. Conclusions: However, even if this technique seems less demanding, the arthroscopic transosseous repair is still an advanced procedure, and should be performed only by well prepared arthroscopic shoulder surgeons. Level of evidence: V. PMID:28717607

  8. Measuring tendon properties in mdx mice: cell viability and viscoelastic characteristics.

    PubMed

    Rizzuto, E; Musarò, A; Catizone, A; Del Prete, Z

    2009-10-16

    Muscular dystrophy is a genetic disorder of skeletal muscle characterized by progressive muscle weakness. Here we assessed whether muscle wasting affects cell viability and mechanical properties of extensor digitorum longus (EDL) and of tibialis anterior (TA) tendons from mdx dystrophic mice compared to wild type (WT) mice. mdx mice represent the classical animal model for human Duchenne muscular dystrophy, and show several signs of the pathology, including a decrease in specific force and an increase of fibrotic index. Cell viability of tendons was evaluated by histological analysis, and viscoelastic properties have been assessed by a rapid measurement protocol that allowed us to compute, at the same time, tissue complex compliance for all the frequencies of interest. Confocal microscopy and mechanical properties measurements revealed that mdx tendons, compared to WT ones, have an increase in the number of dead cells and a significant reduction in tissue elasticity for all the frequencies that were tested. These findings indicate a reduced quality of the tissue. Moreover, mdx tendons have an increase in the viscous response, indicating that during dynamic loading, they dissipate more energy compared to WT. Our results demonstrate that muscular dystrophy involves not only muscle wasting, but also alteration in the viscoelastic properties of tendons, suggesting a paracrine effect of altered skeletal muscle on tendinous tissue.

  9. Incidence and clinical outcomes of tendon rupture following distal radius fracture.

    PubMed

    White, Brian D; Nydick, Jason A; Karsky, Dawnne; Williams, Bailee D; Hess, Alfred V; Stone, Jeffrey D

    2012-10-01

    To evaluate the incidence of tendon rupture after nonoperative and operative management of distal radius fractures, report clinical outcomes after tendon repair or transfer, and examine volar plate and dorsal screw prominence as a predictor of tendon rupture. We performed a retrospective chart review on patients treated for tendon rupture after distal radius fracture. We evaluated active range of motion, Disabilities of Arm, Shoulder, and Hand score, grip strength, and pain score, and performed radiographic evaluation of volar plate and dorsal screw prominence in both the study group and a matched control group. There were 6 tendon ruptures in 1,359 patients (0.4%) treated nonoperatively and 8 tendon ruptures in 999 patients (0.8%) treated with volar plate fixation. At the time of final follow-up, regardless of treatment, we noted that patients had minimal pain and excellent motion and grip strength. Mean Disabilities of the Shoulder, Arm, and Hand scores were 6 for patients treated nonoperatively and 4 for those treated with volar plating. We were unable to verify volar plate or dorsal screw prominence as independent risk factors for tendon rupture after distal radius fractures. However, we recommend continued follow-up and plate removal for symptomatic patients who have volar plate prominence or dorsal screw prominence. In the event of tendon rupture, we report excellent clinical outcomes after tendon repair or tendon transfer. Therapeutic IV. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. Effect of single- and double-row rotator cuff repair at the tendon-to-bone interface: preliminary results using an in vivo sheep model.

    PubMed

    Baums, M H; Schminke, B; Posmyk, A; Miosge, N; Klinger, H-M; Lakemeier, S

    2015-01-01

    The clinical superiority of the double-row technique is still a subject of controversial debate in rotator cuff repair. We hypothesised that the expression of different collagen types will differ between double-row and single-row rotator cuff repair indicating a faster healing response by the double-row technique. Twenty-four mature female sheep were randomly assembled to two different groups in which a surgically created acute infraspinatus tendon tear was fixed using either a modified single- or double-row repair technique. Shoulder joints from female sheep cadavers of identical age, bone maturity, and weight served as untreated control cluster. Expression of type I, II, and III collagen was observed in the tendon-to-bone junction along with recovering changes in the fibrocartilage zone after immunohistological tissue staining at 1, 2, 3, 6, 12, and 26 weeks postoperatively. Expression of type III collagen remained positive until 6 weeks after surgery in the double-row group, whereas it was detectable for 12 weeks in the single-row group. In both groups, type I collagen expression increased after 12 weeks. Type II collagen expression was increased after 12 weeks in the double-row versus single-row group. Clusters of chondrocytes were only visible between week 6 and 12 in the double-row group. The study demonstrates differences regarding the expression of type I and type III collagen in the tendon-to-bone junction following double-row rotator cuff repair compared to single-row repair. The healing response in this acute repair model is faster in the double-row group during the investigated healing period.

  11. Dorsal Arthroscopic Approach and Intra-Articular Anatomy of the Bovine Antebrachiocarpal and Middle Carpal Joints.

    PubMed

    Lardé, Hélène; Nichols, Sylvain; Babkine, Marie; Desrochers, André

    2016-07-01

    To determine arthroscopic approaches to the dorsal synovial compartments of the antebrachiocarpal and middle carpal joints in adult cattle, and to describe the arthroscopic intra-articular anatomy from each approach. Ex vivo study. Six fresh adult bovine cadavers. Two carpi were injected with latex and dissected to determine the ideal location for arthroscopic portals. Arthroscopy of the antebrachiocarpal and middle carpal joints of 10 carpi was then performed. The dorsolateral approach was made between the extensor carpi radialis and common digital extensor tendons. The dorsomedial approach was made medial to the extensor carpi radialis tendon, midway between the distal radius and proximal row of carpal bones (antebrachiocarpal joint) and midway between the two rows of carpal bones (middle carpal joint), with the joint in flexion. Arthroscopy of the antebrachiocarpal joint allowed visualization of the distal radius, proximal aspect of the radial, intermediate and ulnar carpal bones, and a palmar ligament located between the radius and the intermediate carpal bone. The approach to the middle carpal joint allowed visualization of the distal aspect of the radial, intermediate, and ulnar carpal bones, the proximal aspect of the fourth and fused second and third carpal bones and an interosseous ligament. The most lateral articular structures (lateral glenoid cavity of the distal radius, ulnar carpal and fourth carpal bones) were difficult to assess. Dorsal approaches to the antebrachiocarpal and middle carpal joints allowed visualization of most intra-articular dorsal structures in adult cattle. © Copyright 2016 by The American College of Veterinary Surgeons.

  12. Outcome of arthroscopic subscapularis tendon repair: Are the results improving with improved techniques and equipment?: A retrospective case series

    PubMed Central

    Arun, G R; Kumar, Pradeep; Patnaik, Sarthak; Selvaraj, Karthik; Rajan, David; Singh, Anant; Kumaraswamy, Vinay

    2016-01-01

    Background: Rotator cuff tears are a common cause of shoulder pain and dysfunction. More recently, there has been a renewed interest in understanding the subscapularis tears. There are multiple articles in the literature showing the short term results of isolated subscapularis tendon repair. However, the midterm and long term outcome studies for arthroscopic subscapularis repair are few. This study evaluates the functional outcome after arthroscopic subscapularis repair. Materials and Methods: The records of 35 patients who underwent an arthroscopic subscapularis repair between May 2008 and June 2012 were included in this retrospective study. The records of all patients were reviewed. There were 22 males and 13 female patients with mean age of 58.2 years (range 41-72 years). All patients had a complete history, physical examination, and radiographs of their shoulders. Visual analogue scale (VAS), range of movements, power of cuff muscles, and modified University of California at Los Angeles (UCLA) score were assessed. Results: The mean followup was 2.8 years (range 2-4 year). Functional outcome after arthroscopic subscapularis repair has an excellent outcome as analysed by clinical outcome, VAS score and UCLA score. Results were analyzed and had statistically significant values. The VAS for pain improved significantly (P < 0.001), and the mean modified UCLA score improved significantly (P < 0.001) from 14.24 ± 4.72 preoperatively to 33.15 ± 2.29 at 2 years postoperative. According to the UCLA system, there were 22 excellent, 11 good, and 2 fair results. Around 95% of patients returned to their usual work after surgery. Conclusion: At a median followup of 2 years, 95% of patients had a good to excellent result after an arthroscopic subscapularis tendon repair. We conclude that the midterm results show that arthroscopic subscapularis repair remains a good option for the treatment of patients with subscapularis tendon repair. PMID:27293291

  13. Should massive rotator cuff tears be reconstructed even when only partially repairable?

    PubMed

    Godenèche, Arnaud; Freychet, Benjamin; Lanzetti, Riccardo Maria; Clechet, Julien; Carrillon, Yannick; Saffarini, Mo

    2017-07-01

    (1) To evaluate midterm functional outcomes of arthroscopic repair of massive rotator cuff tears and (2) to determine the prognostic factors that could influence outcome. The hypothesis was that both partial and complete repairs would result in equivalent improvement of clinical score. From a prospective series of 525 rotator cuff repairs, we analysed records of the 73 patients who were treated for massive tears. The median follow-up was 41 months (range 29-55), and functional outcome was evaluated using the Constant score, shoulder strength, and subjective shoulder value. The median CS improved from 34 points to 81 points (p < 0.001). The scores were better for both types of two-tendon tears, posterosuperior (83, n = 33) and anterosuperior (85, n = 13) (n.s.), than for three-tendon tears (74, n = 27) (p < 0.001). The scores were also better when fatty infiltration was of stage I (84, n = 28) than of stage II (78, n = 34) (p < 0.001) or stage III (74, n = 11) (p = 0.04). The scores were only slightly higher for completely reparable tears (81.5, n = 50) than for partially reparable tears (79, n = 23) (n.s.). Ultrasonic examination revealed incomplete healing, in 10 of the 50 completely repaired tears, and in 11 of the 23 partially repaired tears. The results of the present study compare favourably with those in recent literature and confirm the hypothesis that both partial and complete repairs of massive rotator cuff tears produce equivalent improvements of Constant scores. The clinical relevance of these observations is that even if repairs of two-tendon tears result in superior functional outcomes, repairs of three-tendon tears produce equivalent 'relative' improvement that grants sufficient patient satisfaction and autonomy. Comparative case series, Level IV.

  14. Knee isokinetic performance following anterior cruciate ligament reconstruction: patellar tendon versus hamstrings graft.

    PubMed

    Machado, Felipe; Debieux, Pedro; Kaleka, Camila Cohen; Astur, Diego; Peccin, Maria Stella; Cohen, Moisés

    2018-02-01

    To compare knee isokinetic performance six months after reconstruction of the anterior cruciate ligament using grafts from either the patellar tendon or the hamstrings among patients who underwent the same rehabilitation protocol. Thirty-four patients were evaluated (17 with grafts from the patellar tendon and 17 with grafts from the hamstrings). Operated and non-operated knees were compared with regards to the variables of peak torque, work and the hamstring/quadriceps relationship at velocities of 60º/s and 180º/s and power of 180º/s after six months of surgery. The patients with ACL reconstruction using the patellar tendon (BPTB) showed quadriceps deficits for all variables, but the flexor musculature was balanced. In the hamstring group, both the extensors and the flexors showed deficits for the variables analyzed, except for hamstring power at 180º/s. Patients in the patellar tendon group had a greater quadriceps deficit compared with those in the hamstrings group. Patients in the hamstrings group had a greater muscular deficit in the flexor mechanism compared with the contralateral knee. An unbalanced H/Q ratio was observed regardless of graft type, but this was more evident in the BPTB group.

  15. Sclerostin Antibody Treatment Enhances Rotator Cuff Tendon-to-Bone Healing in an Animal Model.

    PubMed

    Shah, Shivam A; Kormpakis, Ioannis; Havlioglu, Necat; Ominsky, Michael S; Galatz, Leesa M; Thomopoulos, Stavros

    2017-05-17

    Rotator cuff tears are a common source of pain and disability, and poor healing after repair leads to high retear rates. Bone loss in the humeral head before and after repair has been associated with poor healing. The purpose of the current study was to mitigate bone loss near the repaired cuff and improve healing outcomes. Sclerostin antibody (Scl-Ab) treatment, previously shown to increase bone formation and strength in the setting of osteoporosis, was used in the current study to address bone loss and enhance rotator cuff healing in an animal model. Scl-Ab was administered subcutaneously at the time of rotator cuff repair and every 2 weeks until the animals were sacrificed. The effect of Scl-Ab treatment was evaluated after 2, 4, and 8 weeks of healing, using bone morphometric analysis, biomechanical evaluation, histological analysis, and gene expression outcomes. Injury and repair led to a reduction in bone mineral density after 2 and 4 weeks of healing in the control and Scl-Ab treatment groups. After 8 weeks of healing, animals receiving Scl-Ab treatment had 30% greater bone mineral density than the controls. A decrease in biomechanical properties was observed in both groups after 4 weeks of healing compared with healthy tendon-to-bone attachments. After 8 weeks of healing, Scl-Ab-treated animals had improved strength (38%) and stiffness (43%) compared with control animals. Histological assessment showed that Scl-Ab promoted better integration of tendon and bone by 8 weeks of healing. Scl-Ab had significant effects on gene expression in bone, indicative of enhanced bone formation, and no effect on the expression of genes in tendon. This study provides evidence that Scl-Ab treatment improves tendon-to-bone healing at the rotator cuff by increasing attachment-site bone mineral density, leading to improved biomechanical properties. Scl-Ab treatment may improve outcomes after rotator cuff repair.

  16. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons.

    PubMed

    Thorpe, Chavaunne T; Godinho, Marta S C; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2015-12-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Treatment of osteoarthritis of the first carpometacarpal joint by resection-suspension-interposition arthoplasty using the split abductor pollicis longus tendon.

    PubMed

    Harenberg, P S; Jakubietz, M G; Jakubietz, R G; Schmidt, K; Meffert, R H

    2013-02-01

    Reduction of pain and gain of functionality in symptomatic osteoarthritis of the first carpometacarpal joint. Idiopathic, rheumatic, or posttraumatic osteoarthritis of the first carpometacarpal joint. RELATIVE CONTRAINDICATIONS: Poor general condition, poor condition of the hand's soft tissue/skin, chronic regional pain syndrome, current or recent infections of the hand, heavy manual labor (decision on a by-case basis). Supine position, hand pronated or slightly tilted. Upper arm tourniquet (Esmarch's method). Loupe magnification. Incision over the first extensor compartment. Exposure and incision of the thumb's basal joint. Resection of the trapezium. Exposure of the abductor pollicis longus (APL) tendon. Longitudinal split of the tendon harvesting the distally based ulnar part of the tendon. The split APL tendon is wrapped around the flexor carpi radialis (FCR) muscle tendon, suturing it to the tendon and back to itself. The rest of the split APL tendon is placed into the gap between the scaphoid and the first metacarpal bone, which is followed by wound closure. Plaster cast (thumb abduction splint) for 4 weeks. Stable commercially available wrist brace for at least 2 more weeks. There were no significant differences between the FCR arthroplasty (Epping's method) and the APL arthroplasty (Wulle's technique) regarding pain (visual analog scale), disability/usability (DASH score), or range of motion. Patients who had undergone APL arthroplasty showed significantly better grip and pinch strength. Furthermore, the operating time was significantly shorter and scars were significantly smaller in APL arthroplasty.

  18. In vitro structural properties of braided tendon grafts.

    PubMed

    Nicklin, S; Waller, C; Walker, P; Chung, W K; Walsh, W R

    2000-01-01

    In an effort to increase strength in hamstring tendon grafts for anterior cruciate ligament reconstruction, braiding or weaving of the tendons has been suggested. The purpose of this study was to examine the biomechanical properties of two braiding techniques compared with a four-stranded tendon graft using a sheep model. Digital extensor tendons from 5 adult sheep were harvested in 28 matched pairs and randomly allocated to French plait or four-stranded weave. The grafts were tested in a hydraulic testing machine with the tendons secured in brass grips frozen with liquid carbon dioxide. The tendons were preconditioned to a distraction of 1 mm for 10 cycles followed by testing to failure at 50 mm/sec, with a data acquisition rate of 1,000 Hz. The stiffness, ultimate load to failure, and the mode of failure were recorded. All braided samples failed at the midsubstance, while the four-stranded controls failed at the grip interface. There was a significant reduction in strength and stiffness of the braided samples compared with the controls. This study demonstrated that braiding decreases the strength and stiffness of a four-stranded tendon graft by up to 54% and 85%, respectively. This finding is supported by the work of Hearle et al. (1969), who demonstrated that the decrease in strength of fiber bundles is equal to the square of the cosine of the twist angle. The twist angle in our samples was approximately 45 degrees, which equates to a decrease in strength of 50%.

  19. Tissue Engineering Strategies for the Tendon/ligament-to-bone insertion

    PubMed Central

    Smith, Lester; Xia, Younan; Galatz, Leesa M.; Genin, Guy M.; Thomopoulos, Stavros

    2012-01-01

    Injuries to connective tissues are painful and disabling and result in costly medical expenses. These injuries often require re-attachment of an unmineralized connective tissue to bone. The uninjured tendon/ligament-to-bone insertion (enthesis) is a functionally graded material that exhibits a gradual transition from soft tissue (i.e., tendon or ligament) to hard tissue (i.e., mineralized bone) through a fibrocartilaginous transition region. This transition is believed to facilitate force transmission between the two dissimilar tissues by ameliorating potentially damaging interfacial stress concentrations. The transition region is impaired or lost upon tendon/ligament injury and is not regenerated following surgical repair or natural healing, exposing the tissue to risk of re-injury. The need to regenerate a robust tendon-to-bone insertion has led a number of tissue engineering repair strategies. This review treats the tendon-to-bone insertion site as a tissue structure whose primary role is mechanical and discusses current and emerging strategies for engineering the tendon/ligament-to-bone insertion in this context. The focus lies on strategies for producing mechanical structures that can guide and subsequently sustain a graded tissue structure and the associated cell populations. PMID:22185608

  20. Tissue-engineering strategies for the tendon/ligament-to-bone insertion.

    PubMed

    Smith, Lester; Xia, Younan; Galatz, Leesa M; Genin, Guy M; Thomopoulos, Stavros

    2012-01-01

    Injuries to connective tissues are painful and disabling and result in costly medical expenses. These injuries often require reattachment of an unmineralized connective tissue to bone. The uninjured tendon/ligament-to-bone insertion (enthesis) is a functionally graded material that exhibits a gradual transition from soft tissue (i.e., tendon or ligament) to hard tissue (i.e., mineralized bone) through a fibrocartilaginous transition region. This transition is believed to facilitate force transmission between the two dissimilar tissues by ameliorating potentially damaging interfacial stress concentrations. The transition region is impaired or lost upon tendon/ligament injury and is not regenerated following surgical repair or natural healing, exposing the tissue to risk of reinjury. The need to regenerate a robust tendon-to-bone insertion has led a number of tissue engineering repair strategies. This review treats the tendon-to-bone insertion site as a tissue structure whose primary role is mechanical and discusses current and emerging strategies for engineering the tendon/ligament-to-bone insertion in this context. The focus lies on strategies for producing mechanical structures that can guide and subsequently sustain a graded tissue structure and the associated cell populations.

  1. BIOMECHANICS AND HISTOLOGICAL ANALYSIS IN RABBIT FLEXOR TENDONS REPAIRED USING THREE SUTURE TECHNIQUES (FOUR AND SIX STRANDS) WITH EARLY ACTIVE MOBILIZATION

    PubMed Central

    Severo, Antônio Lourenço; Arenhart, Rodrigo; Silveira, Daniela; Ávila, Aluísio Otávio Vargas; Berral, Francisco José; Lemos, Marcelo Barreto; Piluski, Paulo César Faiad; Lech, Osvandré Luís Canfield; Fukushima, Walter Yoshinori

    2015-01-01

    Objective: Analyzing suture time, biomechanics (deformity between the stumps) and the histology of three groups of tendinous surgical repair: Brazil-2 (4-strands) which the end knot (core) is located outside the tendon, Indiana (4-strands) and Tsai (6-strands) with sutures technique which the end knot (core) is inner of the tendon, associated with early active mobilization. Methods: The right calcaneal tendons (plantar flexor of the hind paw) of 36 rabbits of the New Zealand breed (Oryctolagus cuniculus) were used in the analysis. This sample presents similar size to human flexor tendon that has approximately 4.5 mm (varying from 2mm). The selected sample showed the same mass (2.5 to 3kg) and were male or female adults (from 8 ½ months). For the flexor tendons of the hind paws, sterile and driven techniques were used in accordance to the Committee on Animal Research and Ethics (CETEA) of the University of the State of Santa Catarina (UDESC), municipality of Lages, in Brazil (protocol # 1.33.09). Results: In the biomechanical analysis (deformity) carried out between tendinous stumps, there was no statistically significant difference (p>0.01). There was no statistical difference in relation to surgical time in all three suture techniques with a mean of 6.0 minutes for Tsai (6- strands), 5.7 minutes for Indiana (4-strands) and 5.6 minutes for Brazil (4-strands) (p>0.01). With the early active mobility, there was qualitative and quantitative evidence of thickening of collagen in 38.9% on the 15th day and in 66.7% on the 30th day, making the biological tissue stronger and more resistant (p=0.095). Conclusion: This study demonstrated that there was no histological difference between the results achieved with an inside or outside end knot with respect to the repaired tendon and the number of strands did not affect healing, vascularization or sliding of the tendon in the osteofibrous tunnel, which are associated with early active mobility, with the repair techniques applied. PMID:27027087

  2. The popliteus tendon provides a safe and reliable location for all-inside meniscal repair device placement.

    PubMed

    Ouanezar, Hervé; Blakeney, William G; Latrobe, Charles; Saithna, Adnan; Fernandes, Levi Reina; Delaloye, Jean Romain; Thaunat, Mathieu; Sonnery-Cottet, Bertrand

    2018-03-03

    Repairs of the posterior horn of the lateral meniscus can be technically challenging. In contrast to medial meniscus repairs, the capsule around the posterior segment attachment of the lateral meniscus is quite thin. This study evaluates the clinical results of an arthroscopic all-inside repair technique for unstable, vertical, lateral meniscus tears, using a suture repair placed directly into the popliteus tendon. A retrospective analysis of prospectively collected data from the SANTI database was performed. All patients who had undergone combined ACL reconstruction with lateral meniscus all-inside repair, using sutures placed in the popliteus tendon, between 2011 and 2015, were included. Patients were reviewed clinically at 1 and 2 years' follow-up. At final follow-up, all patients were contacted to identify if they underwent further surgery or had knee pain, locking or effusion. Symptomatic patients were recalled for clinical evaluation by a physician and Magnetic Resonance Imaging of the knee. Operative notes for those undergoing further surgery were reviewed and rates and type of re-operation, including for failed lateral meniscal repair were recorded. Two hundred patients (mean age 28.6 ± 10.2 years) with a mean follow-up of 45.5 ± 12.8 months (range 24.7-75.2) were included. The mean Subjective International Knee Documentation Committee (IKDC) at final follow-up was 85.0 ± 11.3. The post-operative mean side-to-side laxity measured at 1 year was 0.6 ± 1.0 mm. Twenty-six patients underwent re-operation (13%) at a mean follow-up of 14.8 ± 7.8 months. The ACL graft rupture rate was 5.0%. Other causes for re-operation included medial meniscus tear (2.5%), cyclops lesion (1.5%) and septic arthritis (0.5%). The lateral meniscus repair failure rate was 3.5%. No specific complications relating to placement of sutures in the popliteus tendon were identified. Arthroscopic all-inside repair of unstable, vertical, lateral meniscus tears using a suture placed in the popliteus tendon is a safe technique. It is associated with a very low failure rate with no specific complications. Level IV.

  3. [Repair of Achilles tendon rupture and early rehabilitation].

    PubMed

    Delgado-Brambila, H A; Cristiani, D G; Tinajero, E C; Burgos-Elías, V

    2012-01-01

    The frequency of Achilles tendon tear has increased worldwide. Several factors have been described that help explain the mechanism of injury. The treatment of choice continues to be surgery; conservative treatment is reserved for patients with a high morbidity and mortality. Surgical treatment consists of an open or percutaneous technique. In both modalities we try to achieve prompt mobilization of the operated tendon to obtain better and quicker healing. This prospective study describes our experience with 35 patients enrolled from February 2004 to August 2010. They were treated with open repair, physical rehabilitation and active ankle mobilization before the second postoperative week, and with colchicine. We obtained satisfactory results. Patients recovered complete mobility approximately at postoperative week 6, and from weeks 8 to 10 they could resume their daily work activities and participate in sports and recreational activities. Patients were assessed according to the ATRS classification to measure their clinical results. We had no infections or other major complications. We conclude that the open surgical repair of Achilles tendon tear, prompt mobility, and colchicine provide good results.

  4. Tendon basic science: Development, repair, regeneration, and healing.

    PubMed

    Andarawis-Puri, Nelly; Flatow, Evan L; Soslowsky, Louis J

    2015-06-01

    Tendinopathy and tendon rupture are common and disabling musculoskeletal conditions. Despite the prevalence of these injuries, a limited number of investigators are conducting fundamental, basic science studies focused on understanding processes governing tendinopathies and tendon healing. Development of effective therapeutics is hindered by the lack of fundamental guiding data on the biology of tendon development, signal transduction, mechanotransduction, and basic mechanisms underlying tendon pathogenesis and healing. To propel much needed progress, the New Frontiers in Tendon Research Conference, co-sponsored by NIAMS/NIH, the Orthopaedic Research Society, and the Icahn School of Medicine at Mount Sinai, was held to promote exchange of ideas between tendon researchers and basic science experts from outside the tendon field. Discussed research areas that are underdeveloped and represent major hurdles to the progress of the field will be presented in this review. To address some of these outstanding questions, conference discussions and breakout sessions focused on six topic areas (Cell Biology and Mechanics, Functional Extracellular Matrix, Development, Mechano-biology, Scarless Healing, and Mechanisms of Injury and Repair), which are reviewed in this special issue and briefly presented in this review. Review articles in this special issue summarize the progress in the field and identify essential new research directions. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Comparison of Autograft and Allograft with Surface Modification for Flexor Tendon Reconstruction: A Canine in Vivo Model.

    PubMed

    Wei, Zhuang; Reisdorf, Ramona L; Thoreson, Andrew R; Jay, Gregory D; Moran, Steven L; An, Kai-Nan; Amadio, Peter C; Zhao, Chunfeng

    2018-04-04

    Flexor tendon injury is common, and tendon reconstruction is indicated clinically if the primary repair fails or cannot be performed immediately after tendon injury. The purpose of the current study was to compare clinically standard extrasynovial autologous graft (EAG) tendon and intrasynovial allogeneic graft (IAG) that had both undergone biolubricant surface modification in a canine in vivo model. Twenty-four flexor digitorum profundus (FDP) tendons from the second and fifth digits of 12 dogs were used for this study. In the first phase, a model of failed FDP tendon repair was created. After 6 weeks, the ruptured FDP tendons with a scarred digit were reconstructed with the use of either EAG or IAG tendons treated with carbodiimide-derivatized hyaluronic acid and lubricin. At 12 weeks after tendon reconstruction, the digits were harvested for functional, biomechanical, and histologic evaluations. The tendon failure model was a clinically relevant and reproducible model for tendon reconstruction. The IAG group demonstrated improved digit function with decreased adhesion formation, lower digit work of flexion, and improved graft gliding ability compared with the EAG group. However, the IAG group had decreased healing at the distal tendon-bone junction. Our histologic findings verified the biomechanical evaluations and, further, showed that cellular repopulation of allograft at 12 weeks after reconstruction is still challenging. FDP tendon reconstruction using IAG with surface modification has some beneficial effects for reducing adhesions but demonstrated inferior healing at the distal tendon-bone junction compared with EAG. These mixed results indicate that vitalization and turnover acceleration are crucial to reducing failure of reconstruction with allograft. Flexor tendon reconstruction is a common surgical procedure. However, postoperative adhesion formation may lead to unsatisfactory clinical outcomes. In this study, we developed a potential flexor tendon allograft using chemical and tissue-engineering approaches. This technology could improve function following tendon reconstruction.

  6. LATERAL EPICONDYLITIS OF THE ELBOW

    PubMed Central

    Cohen, Marcio; da Rocha Motta Filho, Geraldo

    2015-01-01

    Lateral epicondylitis, also known as tennis elbow, is a common condition that is estimated to affect 1% to 3% of the population. The word epicondylitis suggests inflammation, although histological analysis on the tissue fails to show any inflammatory process. The structure most commonly affected is the origin of the tendon of the extensor carpi radialis brevis and the mechanism of injury is associated with overloading. Nonsurgical treatment is the preferred method, and this includes rest, physiotherapy, cortisone infiltration, platelet-rich plasma injections and use of specific immobilization. Surgical treatment is recommended when functional disability and pain persist. Both the open and the arthroscopic surgical technique with resection of the degenerated tendon tissue present good results in the literature. PMID:27047843

  7. Rupture of the subscapularis tendon after shoulder arthroplasty: diagnosis, treatment, and outcome.

    PubMed

    Miller, Bruce S; Joseph, Thomas A; Noonan, Thomas J; Horan, Marilee P; Hawkins, Richard J

    2005-01-01

    The purpose of this study was to document the diagnosis, surgical treatment, and functional outcome in patients with subscapularis ruptures after shoulder arthroplasty. Prospective objective and subjective data were collected on 7 patients with symptomatic rupture of the subscapularis tendon after shoulder arthroplasty. Presenting signs and symptoms included pain, weakness in internal rotation, increased external rotation, and anterior instability. All patients were treated with surgical repair of the ruptured tendon. Four required repair augmentation with a transfer of the pectoralis major tendon. After subscapularis repair and pectoralis transfer, 2 patients continued to have anterior instability and required an additional operation to address the instability. At a mean follow-up of 2.3 years (range, 18-55 months), the mean American Shoulder and Elbow Surgeons shoulder score in this study group was 63.2. The mean patient satisfaction rating, on a 10-point scale, was 6.2. Factors associated with post-arthroplasty subscapularis ruptures included subscapularis lengthening techniques used to address internal rotation contracture and previous surgery that violated the subscapularis tendon. Symptomatic subscapularis rupture after shoulder arthroplasty introduces the need for additional surgery and a period of protected or delayed rehabilitation after arthroplasty. Although symptoms were adequately addressed with appropriate surgical treatment, decreased functional outcomes were observed.

  8. Muscle atrophy and fatty infiltration after an acute rotator cuff repair in a sheep model

    PubMed Central

    Luan, Tammy; Liu, Xuhui; Easley, Jeremiah T.; Ravishankar, Bharat; Puttlitz, Christian; Feeley, Brian T.

    2015-01-01

    Summary Introduction rotator cuff tears (RCTs) are the most common tendon injury seen in orthopedic patients. Muscle atrophy and fatty infiltration of the muscle are crucial factors that dictate the outcome following rotator cuff surgery. Though less studied in humans, rotator cuff muscle fibrosis has been seen in animal models as well and may influence outcomes as well. The purpose of this study was to determine if the rotator cuff would develop muscle changes even in the setting of an acute repair in a sheep model. We hypothesized that fatty infiltration and fibrosis would be present even after an acute repair six months after initial surgery. Methods twelve female adult sheep underwent an acute rotator cuff tear and immediate repair on the right shoulder. The left shoulder served as a control and did not undergo a tear or a repair. Six months following acute rotator cuff repairs, sheep muscles were harvested to study atrophy, fatty infiltration, and fibrosis by histological analysis, western blotting, and reverse transcription polymerase chain reaction (RT-PCR). Results the repair group demonstrated an increase expression of muscle atrophy, fatty infiltration, and fibrosis related genes. Significantly increased adipocytes, muscle fatty infiltration, and collagen deposition was observed in rotator cuff muscles in the tendon repair group compared to the control group. Conclusions rotator cuff muscle undergoes degradation changes including fatty infiltration and fibrosis even after the tendons are repair immediately after rupture. Level of Evidence Basic Science Study. PMID:26261789

  9. Analysis of achilles tendon vascularity with second-generation contrast-enhanced ultrasound.

    PubMed

    Genovese, Eugenio; Ronga, Mario; Recaldini, Chiara; Fontana, Federico; Callegari, Leonardo; Maffulli, Nicola; Fugazzola, Carlo

    2011-01-01

    To compare morphological, power Doppler, and contrast-enhanced ultrasound (CEUS) features of the Achilles tendon between asymptomatic athletes and athletes who had undergone surgical repair of a previous rupture. Twenty-four athletes were divided in two groups (A and B). Group A included 14 patients with a median age of 32 years (range 27 to 47 years) who had undergone surgical repair for unilateral Achilles tendon rupture. Group B (control group) included 10 subjects with a median age of 34 years (range 27 to 40 years) with no previous or present history of tendinopathy. All patients were evaluated with ultrasound, power Doppler, and CEUS with second-generation contrast agent. We studied the uninjured Achilles tendon in athletes of group A and either the left or the right Achilles tendon of the athletes in group B. CEUS showed a significantly greater ability to detect a greater number of vascular spots within the uninjured tendon of group A compared to group B (<0.05). In athletes who had suffered a tear of an Achilles tendon, CEUS detected small vessels that were not identified by power Doppler ultrasound in the uninjured contralateral Achilles tendon. CEUS is useful to evaluate vascularity not detected by other imaging techniques. Vascularity in the uninjured tendon seems to be increased in patients who had a previous rupture. Copyright © 2011 Wiley Periodicals, Inc.

  10. Lateral epicondylitis of the elbow.

    PubMed

    Tosti, Rick; Jennings, John; Sewards, J Milo

    2013-04-01

    Lateral epicondylitis, or "tennis elbow," is a common musculotendinous degenerative disorder of the extensor origin at the lateral humeral epicondyle. Repetitive occupational or athletic activities involving wrist extension and supination are thought to be causative. The typical symptoms include lateral elbow pain, pain with wrist extension, and weakened grip strength. The diagnosis is made clinically through history and physical examination; however, a thorough understanding of the differential diagnosis is imperative to prevent unnecessary testing and therapies. Most patients improve with nonoperative measures, such as activity modification, physical therapy, and injections. A small percentage of patients will require surgical release of the extensor carpi radialis brevis tendon. Common methods of release may be performed via percutaneous, arthroscopic, or open approaches. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Cross cultural adaptation of the Achilles tendon Total Rupture Score with reliability, validity and responsiveness evaluation.

    PubMed

    Carmont, Michael R; Silbernagel, Karin Grävare; Nilsson-Helander, Katarina; Mei-Dan, Omer; Karlsson, Jon; Maffulli, Nicola

    2013-06-01

    The Achilles tendon Total Rupture Score (ATRS) was developed because of the need for a reliable, valid and sensitive instrument to evaluate symptoms and their effects on physical activity in patients following either conservative or surgical management of an Achilles tendon rupture. Prior to using the score in larger randomized trial in an English-speaking population, we decided to perform reliability, validity and responsiveness evaluations of the English version of the ATRS. Even though the score was published in English, the actual English version has not be validated and compared to the results of the Swedish version. From 2009 to 2010, all patients who received treatment for Achilles tendon rupture were followed up using the English version of the ATRS. Patients were asked to complete the score at 3, 6 and 12 months following treatment for Achilles tendon rupture. The ATRS was completed on arrival in the outpatient clinic and again following consultation. The outcomes of 49 (13 female and 36 male) patients were assessed. The mean (SD) age was 49 (12) years, and 27 patients had treatment for a left-sided rupture, 22 the right. All patients received treatment for ruptured Achilles tendons: 38 acute percutaneous repair, 1 open repair, 5 an Achilles tendon reconstruction using a Peroneus Brevis tendon transfer for delayed presentation, 1 gracilis augmented repair for re-rupture and 4 non-operative treatment for mid-portion rupture. The English version of ATRS was shown to have overall excellent reliability (ICC = 0.986). There was no significant difference between the results with the English version and the Swedish version when compared at the 6-month- or 12-month (n.s.) follow-up appointments. The effect size was 0.93. The minimal detectable change was 6.75 points. The ATRS was culturally adapted to English and shown to be a reliable, valid and responsive method of testing functional outcome following an Achilles tendon rupture.

  12. Patellar tendon rupture repair using Dall-Miles cable.

    PubMed

    Shelbourne, K D; Darmelio, M P; Klootwyk, T E

    2001-01-01

    Ten patients underwent patellar tendon repair with end-to-end suture technique and medial and lateral retinacular repair, as well as reinforcement with a Dall-Miles cable through the patella and tibial tubercle. The cable was tensioned at 60 degrees of flexion to allow immediate range of motion to at least 100 degrees of flexion and to protect the repair from undue tension while healing. Accurate tendon length was obtained from a lateral radiograph of the noninvolved knee in 60 degrees of flexion. Patients were allowed to bear full weight as tolerated postoperatively. A knee immobilizer was worn for approximately 2 weeks when adequate muscular control of the leg was attained. The cable was removed 6-8 weeks postoperatively, at which time range of motion equal to the opposite extremity was sought. Full extension was obtained by 1 week postoperatively. Average postoperative knee flexion was 88 degrees at 2 weeks, 112 degrees at 1 month, 133 at 3 months, and 138 degrees at 6 months compared to flexion of 141 degrees in the noninvolved knee. Mean quadriceps muscle strength 1 year postoperatively was 72%+/-11% of the noninvolved leg. No patient had patella infera or rerupture after surgery. Repair of a patellar tendon rupture with end-to-end techniques reinforced with a Dall-Miles cable allows immediate rehabilitation without the need for prolonged immobilization. This technique allows restoration of full range of motion early postoperatively and enables patients to regain adequate quadriceps strength.

  13. Influence of the initial rupture size and tendon subregion on three-dimensional biomechanical properties of single-row and double-row rotator cuff reconstructions.

    PubMed

    Lorbach, O; Pape, D; Raber, F; Busch, L C; Kohn, D; Kieb, M

    2012-11-01

    Influence of the initial rotator cuff tear size and of different subregions of the SSP tendon on the cyclic loading behavior of a modified single-row reconstruction compared to a suture-bridging double-row repair. Artificial tears (25 and 35 mm) were created in the rotator cuff of 24 human cadaver shoulders. The reconstructions were performed as a single-row repair (SR) using a modified suture configuration or a suture-bridge double-row repair (DR). Radiostereometric analysis was used under cyclic loading (50 cycles, 10–180 N, 10–250 N) to calculate cyclic displacement in three different planes (anteroposterior (x), craniocaudal (y) and mediolateral (z) level). Cyclic displacement was recorded, and differences in cyclic displacement of the anterior compared to the posterior subregions of the tendon were calculated. In small-to-medium tears (25 mm) and medium-to-large tears (35 mm), significant lower cyclic displacement was seen for the SR-reconstruction compared to the DR-repair at 180 N (p ≤ 0.0001; p = 0.001) and 250 N (p = 0.001; p = 0.007) in the x-level. These results were confirmed in the y-level at 180 N (p = 0.001; p = 0.0022) and 250 N (p = 0.005; p = 0.0018). Comparison of the initial tear sizes demonstrated significant differences in cyclic displacement for the DR technique in the x-level at 180 N (p = 0.002) and 250 N (p = 0.004). Comparison of the anterior versus the posterior subregion of the tendon revealed significant lower gap formation in the posterior compared to the anterior subregions in the x-level for both tested rotator cuff repairs (p ≤ 0.05). The tested single-row repair using a modified suture configuration achieved superior results in three-dimensional measurements of cyclic displacement compared to the tested double-row suture-bridge repair. The results were dependent on the initial rupture size of the rotator cuff tear. Furthermore, significant differences were found between tendon subregions of the rotator cuff with significantly higher gap formation for the anterior compared to the posterior subregions.

  14. Lacertus Fibrosus Versus Achilles Allograft Reconstruction for Distal Biceps Tears: A Biomechanical Study.

    PubMed

    Murthi, Anand M; Ramirez, Miguel A; Parks, Brent G; Carpenter, Shannon R

    2017-12-01

    The bicipital aponeurosis, or lacertus fibrosus, can potentially be used as a reconstruction graft in chronic distal biceps tendon tears. To evaluate construct stiffness, load to failure, and failure mechanism with lacertus fibrosus versus Achilles allograft for distal biceps tendon reconstruction. Controlled laboratory study. Ten fresh-frozen matched cadaveric pairs of elbows were used. Three centimeters of the distal biceps tendon was resected. Specimens were randomized to the lacertus fibrosus or Achilles tendon group. In one group, the lacertus fibrosus was released from its distal attachment and then tubularized and repaired intraosseously to the radius. In the other group, an Achilles tendon graft was sutured to the biceps muscle and repaired to the ulna. The prepared radii were rigidly mounted at a 45° angle on a load frame. The proximal biceps muscle was secured in a custom-fabricated cryogenic grip. Displacement was measured using a differential variable reluctance transducer mounted at the radius-soft tissue junction and in the muscle- or muscle allograft-tissue junction proximal to the repair. Specimens were loaded at 20 mm/min until failure, defined as a 3-mm displacement at the radius-soft tissue junction. No significant difference was found in mean load to failure between the lacertus fibrosus and Achilles tendon group (mean ± SD, 20.2 ± 5.5 N vs 16.89 ± 4.54 N; P = .18). Stiffness also did not differ significantly between the lacertus fibrosus and Achilles tendon group (12.3 ± 7.1 kPa vs 10.5 ± 5.7 kPa; P = .34). The primary mode of failure in the lacertus fibrosus group was suture pullout from the tissue at the musculotendinous junction (7 of 10). In the Achilles group, failures were observed at the muscle-allograft interface (3) and the allograft-bone (radial tuberosity) interface (3), and 3 suture failures were observed. The button fixation did not fail in any specimens. The mean stiffness and load-to-failure values were not significantly different between a lacertus fibrosus construct and Achilles tendon allograft. Use of the lacertus fibrosus may be a potential alternative to Achilles tendon allograft reconstruction of chronic distal biceps tears when primary repair is not possible.

  15. Preinjury and postinjury running analysis along with measurements of strength and tendon length in a patient with a surgically repaired Achilles tendon rupture.

    PubMed

    Silbernagel, Karin Grävare; Willy, Richard; Davis, Irene

    2012-06-01

    Case report. The Achilles tendon is the most frequently ruptured tendon, and the incidence of Achilles tendon rupture has increased in the last decade. The rupture generally occurs without any preceding warning signs, and therefore preinjury data are seldom available. This case represents a unique opportunity to compare preinjury running mechanics with postinjury evaluation in a patient with an Achilles tendon rupture. A 23-year-old female sustained a right complete Achilles tendon rupture while playing soccer. Running mechanics data were collected preinjury, as she was a healthy participant in a study on running analysis. In addition, patient-reported symptoms, physical activity level, strength, ankle range of motion, heel-rise ability, Achilles tendon length, and running kinetics were evaluated 1 year after surgical repair. During running, greater ankle dorsiflexion and eversion and rearfoot abduction were noted on the involved side postinjury when compared to preinjury data. In addition, postinjury, the magnitude of all kinetics data was lower on the involved limb when compared to the uninvolved limb. The involved side displayed differences in strength, ankle range of motion, heel rise, and tendon length when compared to the uninvolved side 1 year after injury. Despite a return to normal running routine and reports of only minor limitations with running, considerable changes were noted in running biomechanics 1 year after injury. Calf muscle weakness and Achilles tendon elongation were also found when comparing the involved and uninvolved sides.

  16. Rupture of the anterior tibial tendon: three clinical cases, anatomical study, and literature review.

    PubMed

    Anagnostakos, Konstantinos; Bachelier, Felix; Fürst, Oliver Alexander; Kelm, Jens

    2006-05-01

    We report three cases of anterior tibial tendon ruptures and the results of an anatomical study in regard to the tendon's insertion site and a literature review. Three patients were referred to our hospital with anterior tibial tendon ruptures. In the anatomical study, 53 feet were dissected, looking in particular for variants of the bony insertion of the tendon. Two patients had surgical treatment (one primary repair and one semimembranosus tendon graft) and one conservative treatment. After a mean followup of 14 weeks all patients had satisfactory outcomes. In the anatomical study, we noted three different insertion sites: in 36 feet the tendon inserted into the medial side of the cuneiform and the base of the first metatarsal bone and in 13 feet only into the medial side of the cuneiform bone. In the remaining four feet the tendon inserted into the cuneiform and the first metatarsal bone, but an additional tendon was noted taking its origin from the anterior tibial tendon near its insertion into the medial cuneiform and attaching to the proximal part of the first metatarsal. According to literature, surgical repair is the treatment of choice for acute ruptures and for patients with high activity levels. For chronic ruptures and patients with low demands, conservative management may lead to an equally good outcome. Knowledge of the anatomy in this region may be helpful for diagnosis and for the interpretation of intraoperative findings and choosing the most appropriate surgical procedure.

  17. Structural and biomechanical characteristics after early mobilization in an Achilles tendon rupture model: operative versus nonoperative treatment.

    PubMed

    Krapf, Daniel; Kaipel, Martin; Majewski, Martin

    2012-09-01

    Acute Achilles tendon ruptures are common sports injuries; however, treatment remains a clinical challenge. Studies show a superior effect of early mobilization and full weight bearing on tendon healing and clinical outcome; however, few data exist on structural and biomechanical characteristics in the early healing phase. This study investigated the histological and biomechanical characteristics of early mobilization and full weight bearing in an Achilles tendon rupture model. Eighty rats underwent dissection of a hindpaw Achilles tendon; 40 rats were treated conservatively and 40 underwent open repair of the transected Achilles tendon by suturing. Early mobilization and full weight bearing were allowed in both groups. At 1, 2, 4, and 8 weeks after tenotomy, tensile strength, stiffness, thickness, tissue characteristics (histological analysis), and length were determined. Dissected Achilles tendons healed in all animals during full weight-bearing early mobilization. One and 2 weeks after tenotomy, rats in the operative group showed increased tensile strength and stiffness compared with the nonoperative group. Repair-site diameters were increased at 1, 2, and 8 weeks after tenotomy. Tendon length was decreased in the operative group throughout observation, whereas the nonoperative group showed increased structural characteristics on the cellular level and a more homogeneous collagen distribution. Surgical treatment of dissected rat Achilles tendons showed superior biomechanical characteristics within the first 2 weeks. Conservative treatment resulted in superior histological findings but significant lengthening of the tendon in the early healing phase (weeks 1-8). Copyright 2012, SLACK Incorporated.

  18. MMP inhibition as a potential method to augment the healing of skeletal muscle and tendon extracellular matrix

    PubMed Central

    Davis, Max E.; Gumucio, Jonathan P.; Sugg, Kristoffer B.; Bedi, Asheesh

    2013-01-01

    The extracellular matrix (ECM) of skeletal muscle and tendon is composed of different types of collagen molecules that play important roles in the transmission of forces throughout the body, and in the repair and regeneration of injured tissues. Fibroblasts are the primary cells in muscle and tendon that maintain, repair, and modify the ECM in response to mechanical loading, injury, and inactivity. Matrix metalloproteinases (MMPs) are enzymes that digest collagen and other structural molecules, which are synthesized and excreted by fibroblasts. MMPs are required for baseline ECM homeostasis, but disruption of MMP regulation due to injury or disease can alter the normal ECM architecture and prevent proper force transmission. Chronic injuries and diseases of muscles and tendons can be severely debilitating, and current therapeutic modalities to enhance healing are quite limited. This review will discuss the mechanobiology of MMPs, and the potential use of MMP inhibitors to improve the treatment of injured and diseased skeletal muscle and tendon tissue. PMID:23640595

  19. Sources of adult mesenchymal stem cells for ligament and tendon tissue engineering.

    PubMed

    Dhinsa, Baljinder S; Mahapatra, Anant N; Khan, Wasim S

    2015-01-01

    Tendon and ligament injuries are common, and repair slowly with reduced biomechanical properties. With increasing financial demands on the health service and patients to recover from tendon and ligament injuries faster, and with less morbidity, health professionals are exploring new treatment options. Tissue engineering may provide the answer, with its unlimited source of natural cells that in the correct environment may improve repair and regeneration of tendon and ligament tissue. Mesenchymal stem cells have demonstrated the ability to self renew and have multilineage differentiation potential. The use of bone marrow-derived mesenchymal stem cells has been reported, however significant in vitro culture expansion is required due to the low yield of cells, which has financial implications. Harvesting of bone marrow cells also has associated morbidity. Several studies have looked at alternative sources for mesenchymal stem cells. Reports in literature from animal studies have been encouraging, however further work is required. This review assesses the potential sources of mesenchymal stem cells for tissue engineering in tendons and ligaments.

  20. Extensor Pollicis Longus Injury in Addition to De Quervain’s with Text Messaging on Mobile Phones

    PubMed Central

    Kumar, Bhaskaranand; Bhat, Anil K; Venugopal, Anand

    2014-01-01

    Objective: To do a clinical and ultrasonic evaluation of subjects with thumb pain with text messaging. Background: Thumbs are commonly used for text messaging, which are not as well designed for fine manipulative or dexterous work. Repetitive use as in text messaging can lead to the injury to the tendons of the thumb. Materials and Methods: Ninety eight students with symptoms of Repetitive Strain Type of injuries of the thumb were selected from a survey and evaluated both clinically and by ultrasound analysis of the musculotendinous unit of the thumb to note changes due to excessive use of the mobile phone. Age and sex matched controls were also subjected to ultrasound evaluation. Results: Clinical examination showed positive Finkelstein test in 40% of the cases, significant reduction in the lateral and tip pinch strengths in the cases. Ultrasound detected changes in the first and the third compartments in 19% of the cases. Conclusion: Isolated cases of pain in the thumb have been reported but this study noted changes both clinically and by ultrasound in the tendons of the thumb. These changes should be taken as warning signs of possible subclinical changes taking place in the soft tissues of the thumb in these subjects due to repetitive use of mobile phones and thus, making them prone for developing painful Musculoskeletal Disorders. Application: Repetitive use of mobile phones for text messaging can lead to the damage of Extensor pollicis longus of the thumb in addition to the tendons of the first compartment of the wrist. PMID:25584249

  1. Arthroscopic approach and intra-articular anatomy of the dorsal and plantar synovial compartments of the bovine tarsocrural joint.

    PubMed

    Lardé, Hélène; Nichols, Sylvain; Babkine, Marie; Desrochers, André

    2017-01-01

    To determine arthroscopic approaches to the dorsal and plantar synovial compartments of the tarsocrural joint in adult cattle, and to describe the arthroscopic intra-articular anatomy from each approach. Ex vivo study. Fresh adult bovine cadavers (n = 7). Two tarsocrural joint were injected with latex to determine arthroscopic portal locations and arthroscopy of the tarsocrural joint of 12 tarsi was performed. The dorsolateral approach was made through the large pouch located between the long digital extensor and peroneus longus tendons. The dorsomedial approach was made just medial to the common synovial sheath of the tibialis cranialis, peroneus tertius, and long digital extensor tendons. The plantarolateral and plantaromedial approaches were made lateral and medial to the tarsal tendon sheath, respectively. Each approach allowed visualization of the distal tibia articulating with the proximal trochlea of the talus. Consistently observed structures included the distal intermediate ridge of the tibia, and the medial and lateral trochlear ridges and trochlear groove of the talus. Lateral and medial malleoli were best assessed from dorsal approaches. From the lateral approaches evaluation of the abaxial surface of the lateral trochlear ridge allowed visualization of the fibulocalcaneal joint. From the plantar approaches additional observed structures included the coracoid process of the calcaneus, plantar trochlea of the talus, and plantar talotibial and talofibular ligaments. In cattle, the dorsolateral and plantarolateral approaches allowed for the best evaluation of the dorsal and plantar aspects of the tarsocrural joint, respectively. © 2017 The American College of Veterinary Surgeons.

  2. Architectural properties of the neuromuscular compartments in selected forearm skeletal muscles

    PubMed Central

    Liu, An-Tang; Liu, Ben-Li; Lu, Li-Xuan; Chen, Gang; Yu, Da-Zhi; Zhu, Lie; Guo, Rong; Dang, Rui-Shan; Jiang, Hua

    2014-01-01

    The purposes f this study were to (i) explore the possibility of splitting the selected forearm muscles into separate compartments in human subjects; (ii) quantify the architectural properties of each neuromuscular compartment; and (iii) discuss the implication of these properties in split tendon transfer procedures. Twenty upper limbs from 10 fresh human cadavers were used in this study. Ten limbs of five cadavers were used for intramuscular nerve study by modified Sihler's staining technique, which confirmed the neuromuscular compartments. The other 10 limbs were included for architectural analysis of neuromuscular compartments. The architectural features of the compartments including muscle weight, muscle length, fiber length, pennation angle, and sarcomere length were determined. Physiological cross-sectional area and fiber length/muscle length ratio were calculated. Five of the selected forearm muscles were ideal candidates for splitting, including flexor carpi ulnaris, flexor carpi radials, extensor carpi radialis brevis, extensor carpi ulnaris and pronator teres. The humeral head of pronator teres contained the longest fiber length (6.23 ± 0.31 cm), and the radial compartment of extensor carpi ulnaris contained the shortest (2.90 ± 0.28 cm). The ulnar compartment of flexor carpi ulnaris had the largest physiological cross-sectional area (5.17 ± 0.59 cm2), and the ulnar head of pronator teres had the smallest (0.67 ± 0.06 cm2). Fiber length/muscle length ratios of the neuromuscular compartments were relatively low (average 0.27 ± 0.09, range 0.18–0.39) except for the ulnar head of pronator teres, which had the highest one (0.72 ± 0.05). Using modified Sihler's technique, this research demonstrated that each compartment of these selected forearm muscles has its own neurovascular supply after being split along its central tendon. Data of the architectural properties of each neuromuscular compartment provide insight into the ‘design’ of their functional capability. In addition to improving our understanding of muscle anatomy and function, elucidation of forearm neuromuscular compartments architecture may ultimately provide information useful for selection of muscle subdivisions used in tendon transfer. PMID:24836406

  3. Ultrasonographic diagnostics of pain in the lateral cubital compartment and proximal forearm

    PubMed Central

    Nowicki, Paweł

    2012-01-01

    Pain in the lateral compartment of the elbow joint and decreased strength of the extensor muscle constitute a fairly common clinical problem. These symptoms, occurring in such movements as inverting and converting the forearm, pushing, lifting and pulling, mostly affect people who carry out daily activities with an intense use of wrist, e.g. work on computer. Strains in this area often result from persistent overload and degeneration processes of the common extensor tendon and the radial collateral ligament. Similar symptoms resulting from the compression of deep branch of the radial nerve in radial nerve tunnel should be remembered as well. It happens that both conditions occur simultaneously. A proper diagnosis is essential in undertaking an effective treatment. Ultrasonography is a non-invasive method and the application of high-end apparatus with heads of frequencies exceeding 12 MHz allows for a precise evaluation of joint structures, tendons and nerves. In case of the so-called tennis elbow, the examination allows for evaluation of the degree and extent of injury to the radial collateral ligament and common extensor tendon, in addition to the presence of blood vessels in inflicted area. Administration of autologous blood platelets concentrate containing growth factors, used in treatment of tennis elbow, is performed under ultrasound image control conditions. This allows for a precise incision of scar whilst keeping a healthy (unaffected) tissue margin to form fine channels enabling the penetration of growth factors. Post-surgery medical check-up allows for the evaluation of treatment effectiveness. In radial nerve tunnel syndrome, the ultrasound examination can reveal abnormalities in the deep branch of the radial nerve and within the anatomical structures adjacent to the nerve in the radial nerve tunnel. Furthermore, the ultrasound examination allows for detection of other articular and extraarticular pathologies, which affect the compression of the deep branch of radial nerve, such as skeletal deformations, post-traumatic changes, arthritis, and the presence of tumors. The ultrasonography is also helpful in differentiation of symptoms arising from cervical radiculopathy or brachial plexus injury. PMID:26674710

  4. Extremity salvage with a free musculocutaneous latissimus dorsi flap and free tendon transfer after resection of a large congenital fibro sarcoma in a 15-week-old infant. A case report.

    PubMed

    Germann, G; Waag, K-L; Selle, B; Jester, A

    2006-01-01

    A case of complex microsurgical reconstruction of the dorsum of the foot, including tendon transfer following tumor resection, in a 15-week-old male infant is presented. After birth, a 5.5 x 4 cm large tumor was observed on the dorsum of the right foot. Biopsy showed a congenital malignant fibro sarcoma. After initial chemotherapy a radical excision of the tumor at the age of 14 weeks was followed. To cover the defect a musculocutaneous latissimus dorsi flap was taken, the cutaneous part being large enough to cover the defect. Extensor tendons were reconstructed with free tendon transplants. Amputation is usually indicated in these cases. To the best of our knowledge, microsurgical reconstruction in infants at this age with congenital malignant tumors has not yet been reported. The case shows that Plastic surgery can play an important role in pediatric oncology and should routinely be integrated into the multi-modal treatment concepts. (c) 2006 Wiley-Liss, Inc. Microsurgery, 2006.

  5. [Pattern of paralysis and reconstructive operations after traumatic brachial plexus lesions].

    PubMed

    Rühmann, O; Schmolke, S; Carls, J; Wirth, C J

    2002-12-01

    The aim of this study was to evaluate persistent patterns of paralysis after traumatic brachial plexus lesions. As a result, consecutive reconstructive operations according to our differential therapy concept are presented. Between 04/1994 and 12/2000 in 104 patients with brachial plexus palsy, the grade of muscle power of the affected upper extremities was evaluated prospectively. The neuromuscular patterns of defect showed, in most cases, insufficient muscle power grades of 0-2 for the deltoid muscle (90%), supraspinatus muscle (82%), infraspinatus muscle (93%), elbow flexors (67% to 77%), hand and finger extensors (69% to 71%), and the abductor and extensors of the thumb (67% to 70%). In corresponding frequency, the following operations were performed between 04/1994 and 06/2002: shoulder arthrodesis (n 26), trapezius transfer (n 80), rotation osteotomy of humerus (n 10), triceps to biceps transposition (n 11), transposition of forearm flexors or extensors/Steindler operation (n 12), latissimus transfer (n 7), pectoralis transfer (n 1), teres major transfer (n 1), transposition of forearm flexors to the tendons of extensor digitorum (n 19) and of the extensor pollicis longus (n 9), and wrist arthrodesis (n 5). On malfunction of muscles following brachial plexus lesions, taking into account the individual neuromuscular defect, passive joint function, and bony deformities, different procedures such as muscle transposition, arthrodesis, and corrective osteotomy can be performed to improve function of the upper extremity.

  6. Tendon length and joint flexibility are related to running economy.

    PubMed

    Hunter, Gary R; Katsoulis, Konstantina; McCarthy, John P; Ogard, William K; Bamman, Marcas M; Wood, David S; Den Hollander, Jan A; Blaudeau, Tamilane E; Newcomer, Bradley R

    2011-08-01

    The purpose of study was to determine whether quadriceps/patella and Achilles tendon length and flexibility of the knee extensors and plantar flexors are related to walking and running economy. Twenty-one male distance runners were subjects. Quadriceps/patella and Achilles tendon length were measured by magnetic resonance imaging; body composition was measured DXA; oxygen uptake at rest while seated, walking (3 mph), and running (6 and 7 mph) were measured by indirect calorimetry; knee and ankle joint flexibility were measured by goniometry; and leg lengths were measured by anthropometry while seated. Correlations were used to identify relationships between variables of interest. Net VO2 (exercise VO2 - rest VO2) for walking (NVOWK) and running at 6 and 7 mph (NVO6 and NVO7, respectively) was significantly related to Achilles tendon length (r varying from -0.40 to -0.51, P all < 0.04). Achilles tendon cross section was not related to walking or running economy. Quadriceps/patella tendon length was significantly related to NVO7 (r = -0.43, P = 0.03) and approached significance for NVO6 (r = -0.36, P = 0.06). Flexibility of the plantar flexors was related to NVO7 (+0.38, P = 0.05). Multiple regression showed that Achilles tendon length was independently related to NVO6 and NVO7 (partial r varying from -0.53 to -0.64, all P < 0.02) independent of lower leg length, upper leg length, quadriceps/patella tendon length, knee extension flexibility, or plantarflexion flexibility. These data support the premise that longer lower limb tendons (especially Achilles tendon) and less flexible lower limb joints are associated with improved running economy.

  7. Medialized repair for retracted rotator cuff tears.

    PubMed

    Kim, Young-Kyu; Jung, Kyu-Hak; Won, Jun-Sung; Cho, Seung-Hyun

    2017-08-01

    The purpose of this study was to evaluate the functional outcomes of medialized rotator cuff repair and the continuity of repaired tendon in chronic retracted rotator cuff tears. Thirty-five consecutive patients were selected from 153 cases that underwent arthroscopic rotator cuff repair for more than medium-sized posterosuperior rotator cuff tears between July 2009 and July 2012 performed with the medialized repair. All cases were available for at least 2 years of postoperative follow-up. The visual analog scale of pain, muscle strength, Constant score, American Shoulder and Elbow Surgeons (ASES) score, and University of California-Los Angeles score were evaluated. At the final follow-up, all clinical outcomes were significantly improved. The visual analog scale score for pain improved from 6 ± 1 preoperatively to 2 ± 1 postoperatively. The range of motion increased from preoperatively to postoperatively: active forward elevation, from 134° ± 49° to 150° ± 16°; active external rotation at the side, from 47° ± 15° to 55° ± 10°; and active internal rotation, from L3 to L1. The shoulder score also improved: Constant score, from 53.5 ± 16.7 to 79 ± 10; American Shoulder and Elbow Surgeons score, from 51 ± 15 to 82 ± 8; and University of California-Los Angeles score, from 14 ± 4 to 28 ± 4. The retear cases at the final follow-up were 6 (17%). Medialized repair may be useful in cases in which anatomic bone-to-tendon repair would be difficult because of the excessive tension of the repaired tendon and a torn tendon that does not reach the anatomic insertion. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. The interaction between the vastus medialis and vastus intermedius and its influence on the extensor apparatus of the knee joint.

    PubMed

    Grob, Karl; Manestar, Mirjana; Filgueira, Luis; Kuster, Markus S; Gilbey, Helen; Ackland, Timothy

    2018-03-01

    Although the vastus medialis (VM) is closely associated with the vastus intermedius (VI), there is a lack of data regarding their functional relationship. The purpose of this study was to investigate the anatomical interaction between the VM and VI with regard to their origins, insertions, innervation and function within the extensor apparatus of the knee joint. Eighteen human cadaveric lower limbs were investigated using macro-dissection techniques. Six limbs were cut transversely in the middle third of the thigh. The mode of origin, insertion and nerve supply of the extensor apparatus of the knee joint were studied. The architecture of the VM and VI was examined in detail, as was their anatomical interaction and connective tissue linkage to the adjacent anatomical structures. The VM originated medially from a broad hammock-like structure. The attachment site of the VM always spanned over a long distance between: (1) patella, (2) rectus femoris tendon and (3) aponeurosis of the VI, with the insertion into the VI being the largest. VM units were inserted twice-once on the anterior and once on the posterior side of the VI. The VI consists of a complex multi-layered structure. The layers of the medial VI aponeurosis fused with the aponeuroses of the tensor vastus intermedius and vastus lateralis. Together, they form the two-layered intermediate layer of the quadriceps tendon. The VM and medial parts of the VI were innervated by the same medial division of the femoral nerve. The VM consists of multiple muscle units inserting into the entire VI. Together, they build a potential functional muscular complex. Therefore, the VM acts as an indirect extensor of the knee joint regulating and adjusting the length of the extensor apparatus throughout the entire range of motion. It is of clinical importance that, besides the VM, substantial parts of the VI directly contribute to the medial pull on the patella and help to maintain medial tracking of the patella during knee extension. The interaction between the VM and VI, with responsibility for the extension of the knee joint and influence on the patellofemoral function, leads readily to an understanding of common clinical problems found at the knee joint as it attempts to meet contradictory demands for both mobility and stability. Surgery or trauma in the anteromedial aspect of the quadriceps muscle group might alter a delicate interplay between the VM and VI. This would affect the extensor apparatus as a whole.

  9. Repair of a deep digital tendon deficit in a horse using a polypropylene implant.

    PubMed Central

    Crawford, W H; Ingle, J E

    1997-01-01

    A yearling horse was treated for a chronic wound with a 4 cm deficit in the deep digital tendon. The gap in the tendon was bridged with paired polypropylene braided implants designed for use as a ligament augmentation device. Uncomplicated healing and return to function occurred. Images Figure 1. PMID:9167878

  10. Effect of Exercise-Induced Enhancement of the Leg-Extensor Muscle-Tendon Unit Capacities on Ambulatory Mechanics and Knee Osteoarthritis Markers in the Elderly

    PubMed Central

    Karamanidis, Kiros; Oberländer, Kai Daniel; Niehoff, Anja; Epro, Gaspar; Brüggemann, Gert-Peter

    2014-01-01

    Objective Leg-extensor muscle weakness could be a key component in knee joint degeneration in the elderly because it may result in altered muscular control during locomotion influencing the mechanical environment within the joint. This work aimed to examine whether an exercise-induced enhancement of the triceps surae (TS) and quadriceps femoris (QF) muscle-tendon unit (MTU) capacities would affect mechanical and biological markers for knee osteoarthritis in the elderly. Methods Twelve older women completed a 14-week TS and QF MTU exercise intervention, which had already been established as increasing muscle strength and tendon stiffness. Locomotion mechanics and serum cartilage oligomeric matrix protein (COMP) levels were examined during incline walking. MTU mechanical properties were assessed using simultaneously ultrasonography and dynamometry. Results Post exercise intervention, the elderly had higher TS and QF contractile strength and tendon-aponeurosis stiffness. Regarding the incline gait task, the subjects demonstrated a lower external knee adduction moment and lower knee adduction angular impulse during the stance phase post-intervention. Furthermore, post-intervention compared to pre-intervention, the elderly showed lower external hip adduction moment, but revealed higher plantarflexion pushoff moment. The changes in the external knee adduction moment were significantly correlated with the improvement in ankle pushoff function. Serum COMP concentration increased in response to the 0.5-h incline walking exercise with no differences in the magnitude of increment between pre- and post-intervention. Conclusions This work emphasizes the important role played by the ankle pushoff function in knee joint mechanical loading during locomotion, and may justify the inclusion of the TS MTU in prevention programs aiming to positively influence specific mechanical markers for knee osteoarthritis in the elderly. However, the study was unable to show that COMP is amenable to change in the elderly following a 14-week exercise intervention and, therefore, the physiological benefit of improved muscle function for knee cartilage requires further investigation. PMID:24905024

  11. Effect of exercise-induced enhancement of the leg-extensor muscle-tendon unit capacities on ambulatory mechanics and knee osteoarthritis markers in the elderly.

    PubMed

    Karamanidis, Kiros; Oberländer, Kai Daniel; Niehoff, Anja; Epro, Gaspar; Brüggemann, Gert-Peter

    2014-01-01

    Leg-extensor muscle weakness could be a key component in knee joint degeneration in the elderly because it may result in altered muscular control during locomotion influencing the mechanical environment within the joint. This work aimed to examine whether an exercise-induced enhancement of the triceps surae (TS) and quadriceps femoris (QF) muscle-tendon unit (MTU) capacities would affect mechanical and biological markers for knee osteoarthritis in the elderly. Twelve older women completed a 14-week TS and QF MTU exercise intervention, which had already been established as increasing muscle strength and tendon stiffness. Locomotion mechanics and serum cartilage oligomeric matrix protein (COMP) levels were examined during incline walking. MTU mechanical properties were assessed using simultaneously ultrasonography and dynamometry. Post exercise intervention, the elderly had higher TS and QF contractile strength and tendon-aponeurosis stiffness. Regarding the incline gait task, the subjects demonstrated a lower external knee adduction moment and lower knee adduction angular impulse during the stance phase post-intervention. Furthermore, post-intervention compared to pre-intervention, the elderly showed lower external hip adduction moment, but revealed higher plantarflexion pushoff moment. The changes in the external knee adduction moment were significantly correlated with the improvement in ankle pushoff function. Serum COMP concentration increased in response to the 0.5-h incline walking exercise with no differences in the magnitude of increment between pre- and post-intervention. This work emphasizes the important role played by the ankle pushoff function in knee joint mechanical loading during locomotion, and may justify the inclusion of the TS MTU in prevention programs aiming to positively influence specific mechanical markers for knee osteoarthritis in the elderly. However, the study was unable to show that COMP is amenable to change in the elderly following a 14-week exercise intervention and, therefore, the physiological benefit of improved muscle function for knee cartilage requires further investigation.

  12. Anatomic findings and complications after surgical treatment of chronic, partial distal biceps tendon tears: a case cohort comparison study.

    PubMed

    Ruch, David S; Watters, Tyler Steven; Wartinbee, Daniel A; Richard, Marc J; Leversedge, Fraser J; Mithani, Suhail K

    2014-08-01

    To describe pertinent anatomic findings during repair of chronic, partial distal biceps tendon tears and to compare the complications of surgery with a similar cohort of acute, complete tears. Group 1 included 14 patients (15 elbows) with partial tears managed operatively an average of 10 months from onset of injury or symptoms. Group 2 included a matched cohort of 16 patients (17 elbows) treated for complete, acute tears an average of 19 days from injury. A retrospective review of all 30 patients focused on demographic data, intraoperative findings, and postoperative complications. A single, anterior incision was used in all cases with multiple suture anchors or a bicortical toggling button for fixation of the repair. We evaluated 27 men and 3 women with an average age of 55 years (group 1) and 48 years (group 2). Intratendinous ganglion formation at the site of rupture of the degenerative tendon was observed in 5 cases of partial tears and none of the complete tears. Partial tears involved the lateral aspect or short head of the biceps tendon insertion in all cases. Postoperative complications included lateral antebrachial cutaneous nerve neuritis in 8 group 1 patients and 6 group 2 patients and transient posterior interosseus nerve palsy in 3 group 1 patients. Partial distal biceps tendon ruptures showed a consistent pattern of pathology involving disruption of the lateral side of the tendon insertion involving the small head of the biceps. Degenerative intratendinous ganglion formation was present in one third of cases. Repair of chronic, partial distal biceps tendon injuries may have a higher incidence of posterior interosseous and lateral antebrachial cutaneous nerve palsies. Therapeutic III. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. Novel approach to repair of acute achilles tendon rupture: early recovery without postoperative fixation or orthosis.

    PubMed

    Yotsumoto, Tadahiko; Miyamoto, Wataru; Uchio, Yuji

    2010-02-01

    Immobilization or orthosis is required after conventional Achilles tendon surgery. Hypothesis This new Achilles tendon repair approach enables early rehabilitation without any postoperative immobilization or orthosis. Case series; Level of evidence, 4. Twenty consecutive patients (14 men and 6 women; mean age, 43.4 years; range, 16-70 years) who had acute subcutaneous Achilles tendon rupture were treated by the new method, with an average follow-up of 2.9 years (range, 2-4.8 years). Among them, 15 injuries were sports-related and 5 were work-related. The authors applied a side-locking loop technique of their own design for the core suture, using braided polyblend suture thread, with peripheral cross-stitches added. The patients started active and passive ankle mobilization from the next day, partial weightbearing walking from 1 week, full-load walking from 4 weeks, and double-legged heel raises from 6 weeks after surgery. The range of motion recovery equal to the intact side averaged 3.2 weeks. Double-legged heel raises and 20 continuous single-legged heel raise exercises were possible at an average of 6.3 weeks and 9.9 weeks, respectively. T2-weighted magnetic resonance signal intensity recovered to equal that of the intact portion of the same tendon at 12 weeks. The patients resumed sports activities or heavy labor at an average of 14.4 weeks. The Achilles tendon rupture score averaged 98.3 at 24 weeks. There were no complications. This new Achilles tendon repair approach enables early mobilization exercise without costly specialized orthosis or immobilization and allows an early return to normal life and sports activities, reducing the physical and economic burden on patients.

  14. Return to Function, Complication, and Reoperation Rates Following Primary Pectoralis Major Tendon Repair in Military Service Members.

    PubMed

    Nute, Drew W; Kusnezov, Nicholas; Dunn, John C; Waterman, Brian R

    2017-01-04

    Pectoralis major tendon ruptures have become increasingly common injuries among young, active individuals over the past 30 years; however, there is presently a paucity of reported outcome data. We investigated the ability to return to full preoperative level of function, complications, reoperation rates, and risk factors for failure following surgical repair of the pectoralis major tendon in a cohort of young, highly active individuals. All U.S. active-duty military patients undergoing pectoralis major tendon repair between 2008 and 2013 were identified from the Military Health System using the Management Analysis and Reporting Tool (M2). Demographic characteristics, injury characteristics, and trends in preoperative and postoperative self-reported pain scale (0 to 10) and strength were extracted. The ability to return to the full preoperative level of function and rates of rerupture and reoperation were the primary outcome measures. Univariate analysis followed by multivariate analysis identified significant variables. A total of 257 patients with pectoralis major tendon repair were identified with a mean follow-up (and standard deviation) of 47.8 ± 17 months (range, 24 to 90 months). At the time of the latest follow-up, 242 patients (94%) were able to return to the full preoperative level of military function. Fifteen patients (5.8%) were unable to return to duty because of persistent upper-extremity disability. A total of 15 reruptures occurred in 14 patients (5.4%). Increasing body mass index and active psychiatric conditions were significant predictors of inability to return to function (odds ratio, 1.56 [p = 0.0001] for increasing body mass index; and odds ratio, 6.59 [p = 0.00165] for active psychiatric conditions) and total failure (odds ratio, 1.26 [p = 0.0012] for increasing body mass index; and odds ratio, 2.73 [p = 0.0486] for active psychiatric conditions). We demonstrate that 94% of patients were able to return to the full preoperative level of function within active military duty following surgical repair of pectoralis major tendon rupture and 5.4% of patients experienced rerupture after primary repair. Increasing body mass index and active psychiatric diagnoses are significant risk factors for an inability to return to function and postoperative failures. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  15. Characteristics of Intratendinous Microcirculation Shortly After an Achilles Rupture and Subsequent Treatment Outcomes.

    PubMed

    Chang, Yi-Ping; Shih, Kao-Shang; Chiang, Hongsen; Ma, Hsiao-Li; Lin, Leou-Chyr; Peng, Wei-Chen; Wen, Che-Sheng; Wang, Hsing-Kuo

    2017-01-01

    Early microcirculatory responses after experimental tenotomy are critical to the healing of tendons and their ultimate tensile strength. The effects of changes in microcirculation on the outcomes of tendon healing, however, have not been determined. To assess microcirculation values in injured Achilles tendons in the first 3 months after surgical repair and to correlate the inter-limb microcirculatory changes with functional outcomes at 3 and 6 months after surgery. Case-control study. A university sports physiotherapy laboratory. Thirteen subjects (median age: 45 years; range: 34.8-51.9 years) with a repaired Achilles tendon were recruited. Surgical repair. Measurements were obtained at 1, 2, 3, and 6 months after surgery. Bilateral measurements of tendon microcirculation (total hemoglobin [THb] and oxygen saturation [StO 2 ]) were recorded at the first 3 time points, whereas outcome measures of a Taiwan Chinese version of the Victorian Institute of Sport Assessment Scale-Achilles questionnaire, one-leg hopping distance, the star excursion balance test, and the heel raise index were conducted at the third and fourth time points. Correlations between the inter-limb microcirculatory changes, eg, between the measurements at 2 months and 1 month (2-1) after surgery, at 3 months and 2 months (3-2) after surgery, and at 3 months and 1 month (3-1) after surgery, and the outcome measures were investigated. Compared with the noninjured tendons, the repaired Achilles demonstrated greater THb (at 1, 2, and 3 months; P = .017, .008, and .012 respectively) and StO 2 (at 3 months; P = .017). Furthermore, the THb2-1 and THb3-2, StO 2 2-1, and StO 2 3-2 showed correlations with the heel raise index, differences in the star excursion balance test and one-leg hopping distance between the noninjured leg and injured leg, and Taiwan Chinese version of the Victorian Institute of Sport Assessment Scale-Achilles questionnaire scores (rho -0.921 to 0.855). Changes in the inter-limb microcirculation shortly after Achilles repair were correlated with subsequent symptoms and functional symmetry. III. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  16. Effect of shoulder abduction angle on biomechanical properties of the repaired rotator cuff tendons with 3 types of double-row technique.

    PubMed

    Mihata, Teruhisa; Fukuhara, Tetsutaro; Jun, Bong Jae; Watanabe, Chisato; Kinoshita, Mitsuo

    2011-03-01

    After rotator cuff repair, the shoulder is immobilized in various abduction positions. However, there is no consensus on the proper abduction angle. To assess the effect of shoulder abduction angle on the biomechanical properties of the repaired rotator cuff tendons among 3 types of double-row techniques. Controlled laboratory study. Thirty-two fresh-frozen porcine shoulders were used. A simulated rotator cuff tear was repaired by 1 of 3 double-row techniques: conventional double-row repair, transosseous-equivalent repair, and a combination of conventional double-row and bridging sutures (compression double-row repair). Each specimen underwent cyclic testing followed by tensile testing to failure at a simulated shoulder abduction angle of 0° or 40° on a material testing machine. Gap formation and failure loads were measured. Gap formation in conventional double-row repair at 0° (1.2 ± 0.5 mm) was significantly greater than that at 40° (0.5 ± 0.3mm, P = .01). The yield and ultimate failure loads for conventional double-row repair at 40° were significantly larger than those at 0° (P < .01), whereas those for transosseous-equivalent repair (P < .01) and compression double-row repair (P < .0001) at 0° were significantly larger than those at 40°. The failure load for compression double-row repair was the greatest among the 3 double-row techniques at both 0° and 40° of abduction. Bridging sutures have a greater effect on the biomechanical properties of the repaired rotator cuff tendon at a low abduction angle, and the conventional double-row technique has a greater effect at a high abduction angle. Proper abduction position after rotator cuff repair differs between conventional double-row repair and transosseous-equivalent repair. The authors recommend the use of the combined technique of conventional double-row and bridging sutures to obtain better biomechanical properties at both low and high abduction angles.

  17. Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique.

    PubMed

    Park, Maxwell C; Tibone, James E; ElAttrache, Neal S; Ahmad, Christopher S; Jun, Bong-Jae; Lee, Thay Q

    2007-01-01

    We hypothesized that a transosseous-equivalent repair would demonstrate improved tensile strength and gap formation between the tendon and tuberosity when compared with a double-row technique. In 6 fresh-frozen human shoulders, a transosseous-equivalent rotator cuff repair was performed: a suture limb from each of two medial anchors was bridged over the tendon and fixed laterally with an interference screw. In 6 contralateral matched-pair specimens, a double-row repair was performed. For all repairs, a materials testing machine was used to load each repair cyclically from 10 N to 180 N for 30 cycles; each repair underwent tensile testing to measure failure loads at a deformation rate of 1 mm/sec. Gap formation between the tendon edge and insertion was measured with a video digitizing system. The mean ultimate load to failure was significantly greater for the transosseous-equivalent technique (443.0 +/- 87.8 N) compared with the double-row technique (299.2 +/- 52.5 N) (P = .043). Gap formation during cyclic loading was not significantly different between the transosseous-equivalent and double-row techniques, with mean values of 3.74 +/- 1.51 mm and 3.79 +/- 0.68 mm, respectively (P = .95). Stiffness for all cycles was not statistically different between the two constructs (P > .40). The transosseous-equivalent rotator cuff repair technique improves ultimate failure loads when compared with a double-row technique. Gap formation is similar for both techniques. A transosseous-equivalent repair helps restore footprint dimensions and provides a stronger repair than the double-row technique, which may help optimize healing biology.

  18. Immediate effects of whole body vibration on patellar tendon properties and knee extension torque.

    PubMed

    Rieder, F; Wiesinger, H-P; Kösters, A; Müller, E; Seynnes, O R

    2016-03-01

    Reports about the immediate effects of whole body vibration (WBV) exposure upon torque production capacity are inconsistent. However, the changes in the torque-angle relationship observed by some authors after WBV may hinder the measurement of torque changes at a given angle. Acute changes in tendon mechanical properties do occur after certain types of exercise but this hypothesis has never been tested after a bout of WBV. The purpose of the present study was to investigate whether tendon compliance is altered immediately after WBV, effectively shifting the optimal angle of peak torque towards longer muscle length. Twenty-eight subjects were randomly assigned to either a WBV (n = 14) or a squatting control group (n = 14). Patellar tendon CSA, stiffness and Young's modulus and knee extension torque-angle relationship were measured using ultrasonography and dynamometry 1 day before and directly after the intervention. Tendon CSA was additionally measured 24 h after the intervention to check for possible delayed onset of swelling. The vibration intervention had no effects on patellar tendon CSA, stiffness and Young's modulus or the torque-angle relationship. Peak torque was produced at ~70° knee angle in both groups at pre- and post-test. Additionally, the knee extension torque globally remained unaffected with the exception of a small (-6%) reduction in isometric torque at a joint angle of 60°. The present results indicate that a single bout of vibration exposure does not substantially alter patellar tendon properties or the torque-angle relationship of knee extensors.

  19. Prevalence of triceps tendon tears on MRI of the elbow and clinical correlation.

    PubMed

    Koplas, Monica C; Schneider, Erika; Sundaram, Murali

    2011-05-01

    Triceps tendon injuries are reported to be very rare. To our knowledge, there have been no studies describing its prevalence or injury patterns on MR imaging. The purpose of this retrospective study was to determine the prevalence and patterns of triceps injuries based on a large series of consecutive MR examinations. Clinical correlation was obtained. From 801 consecutive elbow MR examinations over a 15-year period, 28 patients with 30 triceps tendon injuries were identified and graded as partial tendon tear and complete tendon tear. The patients' medical records were reviewed to determine age, gender, cause of tears, and management. The prevalence of triceps tendon injuries was 3.8%. There were 5 women and 23 men with partial or complete tears (mean age: 46.6 years; range: 2.7 to 75.1 years). The most common injury was partial tear, found in 18 patients. There were 10 patients with 12 complete tears (2 had re-torn following surgical repair). A tear was suspected in 12 out 28 (43%) patients prior to the MRI. The most common presenting symptom was pain. The most common cause was athletic injury (8 patients [29%], including weightlifting [2 patients]). Tendon tear was found to be a complication of infection in 6 patients, and in 3 patients the tears were a complication of steroid use. Thirteen tendon tears were surgically repaired (8 of these were complete tears). Triceps tendon injury is not as rare as commonly reported and may often be clinically underdiagnosed.

  20. Ultrasound measures of tendon thickness: Intra-rater, Inter-rater and Inter-machine reliability.

    PubMed

    Del Baño-Aledo, María Elena; Martínez-Payá, Jacinto Javier; Ríos-Díaz, José; Mejías-Suárez, Silvia; Serrano-Carmona, Sergio; de Groot-Ferrando, Ana

    2017-01-01

    Ultrasound imaging is often used by physiotherapists and other healthcare professionals but the reliability of image acquisition with different ultrasound machines is unknown. The objective was to compare the intra-rater, inter-rater and intermachine reliability of thickness measurements of the plantar fascia (PF), Achilles tendon (AT), patellar tendon (PT) and elbow common extensor tendon (ECET) with musculoskeletal ultrasound imaging (MSUS). Tendon thickness was measured in four anatomical structures (14 participants, 28 images per tendon) by two sonographers and with two different ultrasound machines. Intraclass Correlation Coefficients (ICCs) and Bland-Altman plots were calculated. The standard error of measurement (SEM) and minimum detectable difference (MDD) were calculated. Inter-rater reliability was excellent for AT (ICC=0.98; 95% CI= 0.96-0.99) and very good for PT (ICC=0.85; 95% CI = 0.67-0.93) and ECET (ICC=0.81; 95% CI= 0.72-0.94). Reliability for PF was moderate, with an ICC of 0.63 (CI 95%= 0.20-0.83). Bland-Altman plot for inter-machine reliability showed a mean difference of 1 m for PF measurements and a mean difference of 4 m and 20 m for AT and PT. The relative SEMs were below 7% and the MDCs were below 0.7 mm. The MSUS reliability in measuring thickness of the four tendons is confirmed by the homogeneous readings intra sonographers, between operators and between different machines. Level of evidence: Tendon thickness can be measured reliably on different ultrasound devices, which is an important step forward in the use of this technique in daily clinical practice and research. III.

  1. Intraoperative extracorporeal autogenous irradiated tendon grafts for functional limb salvage surgery of soft tissue sarcomas of the wrist and hand.

    PubMed

    Omori, Shinsuke; Hamada, Kenichiro; Outani, Hidetatsu; Oshima, Kazuya; Joyama, Susumu; Tomita, Yasuhiko; Naka, Norifumi; Araki, Nobuhito; Yoshikawa, Hideki

    2015-05-12

    In patients with soft tissue sarcoma of the wrist and hand, limb salvage operation is extremely challenging for surgeons in attempting a complete tumor resection with negative surgical margins. In this study, we report four patients with soft tissue sarcoma of the wrist and hand treated by limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts. The patients were all male, and the mean age at the time of surgery was 45 years. Histological diagnoses included clear cell sarcoma in two patients, synovial sarcoma in one, and angiosarcoma in one. All four patients had high grade tumors, wherein three had American Joint Committee on Cancer (AJCC) stage III disease and one with AJCC stage IV disease. The tumors were resected en bloc with involved tendons. The tendons were isolated from the resected tissues, irradiated ex vivo, and re-implanted into the host tendons. In one patient, the bone was resected additionally because of tumor invasion to the bone. Hand function was evaluated using Musculoskeletal Tumor Society (MSTS) rating system. Of the four patients, three died of distant metastatic disease. The remaining patient lives and remains disease-free. The mean follow-up period was 33 months. One patient had local recurrence outside the irradiated graft at 20 months after surgery. The functional rating was 22. Lower scores were seen in patients with reconstruction of flexor tendons than extensor tendons. Limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts is an acceptable method in selected patients with soft tissue sarcoma of the wrist and hand.

  2. [Histomorphological analyse of accelerating the fibrocartilage layer repair of patella-patellar tendon junction in rabbits by low intensity pulsed ultrasound stimulation].

    PubMed

    Zhang, Baoliang; Lü, Hongbin; Hu, Jianzhong; Xu, Daqi; Zhou, Jingyong; Wang, Ye

    2013-08-01

    To analyse the effect of low intensity pulsed ultrasound stimulation (LIPUS) on accelerating the fibrocartilage layer repair of patella-patellar tendon junction. A total of 60 mature female New Zealand white rabbits undergoing standard partial patellectomy were divided into 2 groups randomly. The control group was given comfort treatment and the treatment group was given LIPUS treatment starting from day 3 to the end of week 6 postoperatively. The scheduled time points of animal euthanization would be at week 6, week 12 and week 18 postoperatively. The patella-patellar tendon (PPT) complex would be harvested and cut into sections after decalcification for H&E staining, Safranine o/fast green staining. The thickness and gray value of fibrocartilage layer were analyzed by SANO Microscope Partner image analyzer. At week 6, week 12 and week 18 postoperatively, the fibrocartilage layer in the treatment group was significantly thicker than that in the control group (P<0.01), and the gray value of fibrocartilage layer was significantly smaller than that in the control group (P<0.01). LIPUS helps to accelerate the fibrocartilage layer repair of patella-patellar tendon junction in rabbit models.

  3. Knotless Repair of Achilles Tendon Rupture in an Elite Athlete: Return to Competition in 18 Weeks.

    PubMed

    Byrne, Paul A; Hopper, Graeme P; Wilson, William T; Mackay, Gordon M

    Rupture of the Achilles tendon is an increasingly common injury, particularly in physically active males, and current evidence favors minimally invasive surgical repair. We describe the case of a 36-year-old male elite bobsled athlete with complete rupture of the Achilles tendon. He was treated with surgical repair of the ruptured tendon using an innovative, minimally invasive procedure based on an internal bracing concept and was able to undergo early mobilization and aggressive physiotherapy rehabilitation. His recovery was such that he returned to training at 13 weeks postoperatively and participated in an international competition at 18 weeks, winning a World Cup silver medal. He subsequently raced at the 2014 Winter Olympic Games at 29 weeks after surgery. At >2 years since his injury, he has experienced no complications or reinjury. This represents an exceptional recovery that far exceeds the standard expected for such injuries. The use of this technique for athletes could enable accelerated return to sporting activity and attainment of their preinjury activity levels. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Imaging of the rabbit supraspinatus enthesis at 7 Tesla: a 4-week time course after repair surgery and effect of channeling.

    PubMed

    Trudel, Guy; Melkus, Gerd; Cron, Greg O; Louati, Hakim; Sheikh, Adnan; Larson, Peder E Z; Schweitzer, Mark; Lapner, Peter; Uhthoff, Hans K; Laneuville, Odette

    2017-08-01

    To image the supraspinatus enthesis reformation of rabbit shoulders by magnetic resonance at 7 Tesla (T) using T2 mapping after surgical repair and to assess the effects of channeling aimed at enhancing enthesis reformation. In 112 rabbits, the distal supraspinatus (SSP) tendon was unilaterally detached and reattached after 1 week. At the first surgery, channeling was performed at the footprint in 64 rabbits. At the second surgery, the SSP tendon of all rabbits was re-attached to the greater tuberosity. The shoulders were harvested at 0, 1, 2, or 4 weeks after the repair surgery and were imaged at 7T. Quantitative T2 mapping was performed using multi slice two-dimensional multi-echo spin-echo sequence with fat saturation. Enthesis regions of interests were drawn on three slices at the footprint to measure T2 relaxation times. Tendon repair (F (2, 218)  = 44; P < 2.2e-16) and postoperative duration (F (3, 218)  = 4.8; P = 0.006) both affected significantly the T2 values while channeling had no significant effect. For the time effect, the only pair with a statistical difference was the 0-week and 4-week for the channeling groups (P = 0.023). Enthesis reformation early after surgical repair of the SSP distal tendon was characterized by increasing T2 values. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:461-467. © 2017 International Society for Magnetic Resonance in Medicine.

  5. Randomized controlled trial of accelerated rehabilitation versus standard protocol following surgical repair of ruptured Achilles tendon.

    PubMed

    Porter, Mark D; Shadbolt, Bruce

    2015-05-01

    There is no consensus regarding the optimal management of the acutely ruptured Achilles tendon (TA). Functional bracing alone achieves outcomes similar to those of surgical repair. Surgical repair combined with immediate mobilization may improve the clinical outcome further. The purpose of our study was to determine if an accelerated rehabilitation programme following surgical repair of the ruptured TA could improve clinical outcome, relative to the standard protocol. Patients with an acutely ruptured TA were randomly allocated to undergo an accelerated programme (AP) or standard programme (SP), following surgery. Outcome was assessed at 12 months post-surgery using the Achilles tendon Total Rupture Score (ATRS), the heel-raise height and the time taken to return to running. Fifty-one patients completed the study, 25 in the AP group and 26 in the SP group. At 12 months post-surgery, the ATRS results were similar in the two treatment groups (87.46 in AP with standard error (SE) of 0.735 versus 87.12 in SP with SE of 0.75) while the AP group had less lengthening of the TA (0.385 cm, SE 0.166 versus 1.00 cm, SE 0.169) and a more rapid return to running (17.231 weeks, SE 0.401 versus 21.08 weeks, SE 0.409), than the SP group. The accelerated rehabilitation programme resulted in less tendon lengthening, more rapid return to running, but similar ATRS relative to the standard rehabilitation. Immobilization following TA repair may prolong recovery. © 2014 Royal Australasian College of Surgeons.

  6. Biomechanical Analysis of All-Inside, Arthroscopic Suture Repair Versus Extensor Retinaculum Capsulorrhaphy for Triangular Fibrocartilage Complex Tears With Instability.

    PubMed

    Patel, Amar A; Alhandi, Ali A; Milne, Edward; Dy, Christopher J; Latta, Loren L; Ouellette, E Anne

    2016-03-01

    To assess ulnocarpal joint stability after treatment of a peripheral triangular fibrocartilage complex (TFCC) injury with all-inside arthroscopic suture repair (SR), extensor retinaculum capsulorrhaphy with the Herbert sling (HS), and a combination of both (SR+HS). Twelve fresh-frozen, age-matched, upper-extremity specimens intact from the distal humerus were prepared. Nondestructive mechanical testing was performed to assess native ulnocarpal joint stability and load-displacement curves were recorded. A peripheral, ulnar-sided TFCC injury was created with arthroscopic assistance, and mechanical testing was performed. Each specimen was treated with SR or HS and testing was repeated. The 6 specimens treated with SR were then treated with HS (SR+HS), and testing was repeated. We used paired Student t tests for statistical analysis within cohorts. For all cohorts, there was an average increase in ulnar translation after the creation of a peripheral TFCC injury and an average decrease after repair. Herbert sling decreased translation by 21%, SR decreased translation by 12%, and SR+HS decreased translation by 26%. Suture repair plus HS and HS reduce ulnar translation the most after a peripheral TFCC injury, followed by SR alone. Ulnocarpal joint stability should be assessed clinically in patients with peripheral TFCC injury, and consideration should be made for using extensor capsulorrhaphy in isolation or as an adjunct to SR as a treatment option. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  7. Prospective randomized clinical trial of aggressive rehabilitation after acute Achilles tendon ruptures repaired with Dresden technique.

    PubMed

    De la Fuente, Carlos; Peña y Lillo, Roberto; Carreño, Gabriel; Marambio, Hugo

    2016-03-01

    Rupture of the Achilles tendon is a common injury during working years. Aggressive rehabilitation may provide better outcomes, but also a greater chance of re-rupture. To determine if aggressive rehabilitation has better clinical outcomes for Achilles tendon function, Triceps surae function, one-leg heel rise capacity and lower complication rate during twelve weeks after percutaneous Achilles tendon repair compared to conventional rehabilitation. Randomized controlled trial. Thirty-nine patients were prospectively randomized. The aggressive group (n=20, 41.4 ± 8.3 years) received rehabilitation from the first day after surgery. The conventional group (n=19, 41.7 ± 10.7 years) rested for 28 days, before rehabilitation started. The statistical parameters were the Achilles tendon rupture score (ATRS), verbal pain scale, time to return to work, pain medication consumption, Achilles tendon strength, dorsiflexion range of motion (RoM), injured-leg calf circumference, calf circumference difference, one-leg heel rise repetition and difference, re-rupture rate, strength deficit rate, and other complication rates. Mixed-ANOVA and Bonferroni's post hoc test were performed for multiple comparisons. Student's t-test was performed for parameters measured on the 12th week. The aggressive group with respect to the conventional group had a higher ATRS; lower verbal pain score; lower pain medication consumption; early return to work; higher Achilles tendon strength; higher one-leg heel rise repetitions; and lower one-leg heel rise difference. The re-rupture rate was 5% and 5%, the strength deficit rate was 42% and 5%, and other complications rate was 11% and 15% in the conventional and aggressive group, respectively. Patients with Dresden repair and aggressive rehabilitation have better clinical outcomes, Achilles tendon function and one-leg heel rise capacity without increasing the postoperative complications rate after 12 weeks compared to rehabilitation with immobilization and non-weight-bearing during the first 28 days after surgery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Simultaneous bilateral distal biceps tendon ruptures repaired using an endobutton technique: a case report.

    PubMed

    Dacambra, Mark P; Walker, Richard Ea; Hildebrand, Kevin A

    2013-08-23

    The simultaneous rupture of both distal biceps tendons is a rare clinical entity that is difficult to treat and can have poor outcomes. A variety of treatment and rehabilitation options exist and have been reported for single sided and staged bilateral repairs, but none have described an approach for acute bilateral ruptures. Repairing distal biceps tendon ruptures using a single anterior incision and a cortical suspensory button technique has become increasingly popular in recent years. We present a report of our surgical approach using an endobutton technique and rehabilitation algorithm for this unusual injury pattern. A 43-year-old Caucasian man presented with acute onset bilateral elbow pain while lifting a large sheet of drywall off the ground. He initially felt a 'pop' on the right and almost immediately felt another on the left after having to quickly shift the weight. He was unable to continue working and sought medical attention. His pain was predominantly in his bilateral antecubital fossae and he had significant swelling and ecchymoses. His clinical examination demonstrated no palpable tendon, a retracted biceps muscle belly, and clear supination weakness. Magnetic resonance imaging was performed and showed bilateral distal biceps tendon ruptures with retraction on both sides. After discussion with our patient, we decided that both sides would be repaired using a single anterior incision with endobutton fixation, first his right followed by his left six weeks later. Overall, our patient did very well and had returned to full manual work by our last follow-up at 30 months. Although he was never able to return to competitive recreational hockey and was left with mild lateral antebrachial cutaneous nerve dysesthesias on his right, he felt he was at 85% of his premorbid level of function. We describe what we believe to be, to the best of our knowledge, the first case of simultaneous bilateral distal biceps tendon ruptures successfully treated with a single-incision endobutton technique, which represents a valid option in managing this difficult problem.

  9. Biomechanical properties of double- and single-row suture anchor repair for surgical treatment of insertional Achilles tendinopathy.

    PubMed

    Beitzel, Knut; Mazzocca, Augustus D; Obopilwe, Elifho; Boyle, James W; McWilliam, James; Rincon, Lina; Dhar, Yasmin; Arciero, Robert A; Amendola, Annunziato

    2013-07-01

    Because of intratendinous ossifications, retrocalcaneal bursitis, or intratendinous necrosis commonly found in insertional tendinosis, it is often necessary to detach the tendon partially or entirely from its tendon-to-bone junction. Double-row repair for insertional Achilles tendinopathy will generate an increased contact area and demonstrate higher biomechanical stability. Controlled laboratory study. Eighteen cadaver Achilles tendons were split longitudinally and detached, exposing the calcaneus; an ostectomy was performed and the tendon was reattached to the calcaneus in 1 of 2 ways: 2 suture anchors (single row) or a 4-anchor (double row) construct. Footprint area measurements over time, displacement after cyclic loading (2000 cycles), and final load to failure were measured. The double-row refixation technique was statistically superior to the single-row technique in footprint area measurement initially and 5 minutes after repair (P = .009 and P = .01, respectively) but not after 24 hours (P = .713). The double-row construct demonstrated significantly improved measures for peak load (433.9 ± 84.3 N vs 212.0 ± 49.7 N; P = .042), load at yield (354.7 ± 106.2 N vs 198.7 ± 39.5 N; P = .01), and slope (51.8 ± 9.9 N/mm vs 66.7 ± 16.2 N/mm; P = .021). Cyclic loading did not demonstrate significant differences between the 2 constructs. Double-row construct for reinsertion of a completely detached Achilles tendon using proximal and distal rows resulted in significantly larger contact area initially and 5 minutes after repair and led to significantly higher peak load to failure on destructive testing. In treatment for insertional Achilles tendinosis, the tendon often has to be detached and anatomically reattached to its insertion at the calcaneus. To our knowledge there is a lack of biomechanical studies supporting either a number or a pattern of suture anchor fixation. Because the stresses going across the insertion site of the Achilles tendon are significant during rehabilitation and weightbearing activities, it is imperative to have a strong construct that allows satisfactory healing during the early postoperative process.

  10. Characterization and Surgical Management of Achilles Tendon Sleeve Avulsions.

    PubMed

    Huh, Jeannie; Easley, Mark E; Nunley, James A

    2016-06-01

    An Achilles sleeve avulsion occurs when the tendon ruptures distally from its calcaneal insertion as a continuous "sleeve." This relatively rare injury pattern may not be appreciated until the time of surgery and can be challenging to treat because, unlike a midsubstance rupture, insufficient tendon remains on the calcaneus to allow for end-to-end repair, and unlike a tuberosity avulsion fracture, any bony element avulsed with the tendon is inadequate for internal fixation. This study aimed to highlight the characteristics of Achilles sleeve avulsions and present the outcomes of operative repair using suture anchor fixation. A retrospective analysis was conducted on 11 consecutive Achilles tendon sleeve avulsions (10 males, 1 female; mean age 44 years) that underwent operative repair between 2008 and 2014. Patient demographics, injury presentation, and operative details were reviewed. Postoperative outcomes were collected at a mean follow-up of 38.4 (range, 12-83.5) months, including the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot score, visual analog scale (VAS) for pain, plantarflexion strength, patient satisfaction, and complications. Eight patients (72.7%) had preexisting symptoms of insertional Achilles disease. Ten of 11 (90.9%) injuries were sustained during recreational athletic activity. An Achilles sleeve avulsion was recognized preoperatively in 7 of 11 (64%) cases, where lateral ankle radiographs demonstrated a small radiodensity several centimeters proximal to the calcaneal insertion. Intraoperatively, 90.9% of sleeve avulsions had a concomitant Haglund deformity and macroscopic evidence of insertional tendinopathy. All patients healed after suture anchor repair. The average AOFAS score was 92.8 and VAS score was 0.9. Ten patients (90.9%) were completely satisfied. One complication occurred, consisting of delayed wound healing. Achilles tendon sleeve avulsions predominantly occurred in middle-aged men with preexisting insertional disease, while engaged in athletic activity. Suture anchor fixation, combined with addressing concomitant insertional pathology, was a reliable and safe technique for the operative management of Achilles tendon sleeve avulsions. The majority of patients returned to their preinjury levels of work and recreational activity. Level IV, retrospective case series. © The Author(s) 2016.

  11. Effect of platelet-rich plasma and porcine dermal collagen graft augmentation for rotator cuff healing in a rabbit model.

    PubMed

    Chung, Seok Won; Song, Byung Wook; Kim, Yeun Ho; Park, Kyoung Un; Oh, Joo Han

    2013-12-01

    The rate of healing failure after surgical repair of chronic rotator cuff tears is considerably high. To verify the effect of platelet-rich plasma (PRP) with and without porcine dermal collagen graft augmentation on tendon-to-bone healing, using the rabbit supraspinatus tendon. Controlled laboratory study. A total of 80 rabbits were randomly allocated into 4 groups (20 rabbits per group: 12 for histological and 8 for mechanical testing): repair (R), repair + patch augmentation (RPa), repair + PRP (RPr), and repair + patch + PRP (RPaPr). The right shoulder was used for experimental interventions, and the left served as a control. Six weeks after the detachment of the supraspinatus, the torn tendon was repaired in a transosseous manner, simulating double-row repair in all groups. Platelet-rich plasma was prepared and applied onto the repair site in the RPr and RPaPr groups, and the patch was used to augment the repair in the RPa and RPaPr groups. The mechanical tensile strength test was performed at 8 weeks after repair and the histological evaluation at 4 and 8 weeks. At 4 weeks, the collagen fibers were poorly organized, and fiber continuity was not established in all groups. However, vascularity and cellularity were higher with granulation tissue formation in the PRP-treated groups (RPr and RPaPr) than the nontreated groups (R and RPa). At 8 weeks, tendon-to-bone integration was much improved with more collagen fibers, and longitudinally oriented collagen fibers were visible in all groups. The PRP-treated groups showed better collagen fiber continuity and orientation than the nontreated groups; however, no distinctive difference was found between the patch-augmented groups (RPa and RPaPr) and nonaugmented groups (R and RPr). The mean load-to-failure results were 61.57 ± 29.99 N, 76.84 ± 16.08 N, 105.35 ± 33.82 N, and 117.93 ± 12.60 N for the R, RPa, RPr, and RPaPr groups, respectively, and they were significantly different between the R and RPr (P = .018), R and RPaPr (P = .002), and RPa and RPaPr (P = .029) groups. This animal study showed the enhancement of tendon-to-bone healing after local administration of autologous PRP assessed by histological and biomechanical testing in a rabbit model of chronic rotator cuff tears. However, there was little additive effect of the patch graft. The use of PRP might be a biological supplement to increase the rotator cuff healing rate, which still remains low even after successful cuff repair, but this result should be interpreted with caution regarding clinical applications.

  12. SECEC Research Grant 2008 II: Use of platelet- and leucocyte-rich fibrin (L-PRF) does not affect late rotator cuff tendon healing: a prospective randomized controlled study.

    PubMed

    Zumstein, Matthias A; Rumian, Adam; Thélu, Charles Édouard; Lesbats, Virginie; O'Shea, Kieran; Schaer, Michael; Boileau, Pascal

    2016-01-01

    Because the retear rate after rotator cuff repairs remains high, methods to improve healing are very much needed. Platelet-rich concentrates have been shown to enhance tenocyte proliferation and promote extracellular matrix synthesis in vitro; however, their clinical benefit remains unclear. We hypothesized that arthroscopic rotator cuff repair with leucocyte- and platelet-rich fibrin (L-PRF) results in better clinical and radiographic outcome at 12 months of follow-up than without L-PRF. Thirty-five patients were randomized to receive arthroscopic rotator cuff repair with L-PRF locally applied to the repair site (L-PRF+ group, n = 17) or without L-PRF (L-PRF- group, n = 18). Preoperative and postoperative clinical evaluation included the Subjective Shoulder Value, visual analog score for pain, Simple Shoulder Test, and Constant-Murley score. The anatomic watertight healing, tendon thickness, and tendon quality was evaluated using magnetic resonance arthrography at 12 months of follow-up. No complications were reported in either group. The mean Subjective Shoulder Value, Simple Shoulder Test, and Constant-Murley scores increased from preoperatively to postoperatively, showing no significant differences between the groups. Complete anatomic watertight healing was found in 11 of 17 in the L-PRF+ group and in 11 of 18 in the L-PRP- group (P = .73). The mean postoperative defect size (214 ± 130 mm(2) in the L-PRF+ group vs 161 ± 149 mm(2) in the L-PRF- group; P = .391) and the mean postoperative tendon quality according to Sugaya (L-PRF+ group: 3.0 ± 1.4, L-PRF- group: 3.0 ± 0.9) were similar in both groups at 12 months of follow-up. Arthroscopic rotator cuff repair with application of L-PRF yields no beneficial effect in clinical outcome, anatomic healing rate, mean postoperative defect size, and tendon quality at 12 months of follow-up. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  13. Factors affecting healing after arthroscopic rotator cuff repair

    PubMed Central

    Abtahi, Amir M; Granger, Erin K; Tashjian, Robert Z

    2015-01-01

    Rotator cuff repair has been shown to have good long-term results. Unfortunately, a significant proportion of repairs still fail to heal. Many factors, both patient and surgeon related, can influence healing after repair. Older age, larger tear size, worse muscle quality, greater muscle-tendon unit retraction, smoking, osteoporosis, diabetes and hypercholesterolemia have all shown to negatively influence tendon healing. Surgeon related factors that can influence healing include repair construct-single vs double row, rehabilitation, and biologics including platelet rich plasma and mesenchymal stem cells. Double-row repairs are biomechanically stronger and have better healing rates compared with single-row repairs although clinical outcomes are equivalent between both constructs. Slower, less aggressive rehabilitation programs have demonstrated improved healing with no negative effect on final range of motion and are therefore recommended after repair of most full thickness tears. Additionally no definitive evidence supports the use of platelet rich plasma or mesenchymal stem cells regarding improvement of healing rates and clinical outcomes. Further research is needed to identify effective biologically directed augmentations that will improve healing rates and clinical outcomes after rotator cuff repair. PMID:25793161

  14. Deep and shallow forms of the sulcus for extensor carpi ulnaris.

    PubMed

    Nakashima, T; Hojo, T; Furukawa, H

    1993-12-01

    Anatomical variations in the sulcus for the tendon of extensor carpi ulnaris were studied in 240 upper limbs. The sulcus lies between the head and the styloid process on the dorsal surface of the distal end of the ulna. This groove has deep and shallow forms and, rarely, a flat form. The sulcus was classified into 4 grades according to its depth. Grade I, a deep sulcus, was found in 51.3%. Grades II and III are shallow, but the styloid process in grade II is more prominent than in grade III. The former was found in 28.8%, the latter in 14.2%. Grade IV is a flat form. This was rare and found only in 1.3%. This variation was not age-related, but was a congenital feature.

  15. Influence of Preoperative Musculotendinous Junction Position on Rotator Cuff Healing After Double-Row Repair.

    PubMed

    Tashjian, Robert Z; Erickson, Gregory A; Robins, Richard J; Zhang, Yue; Burks, Robert T; Greis, Patrick E

    2017-06-01

    The primary purpose of this study was to determine the effect of the preoperative position of the musculotendinous junction (MTJ) on rotator cuff healing after double-row arthroscopic rotator cuff repair. A secondary purpose was to evaluate how tendon length and MTJ position change when the rotator cuff heals. Preoperative and postoperative magnetic resonance imaging (MRI) scans of 42 patients undergoing arthroscopic double-row rotator cuff repair were reviewed. Patients undergoing repairs with other constructs or receiving augmented repairs (platelet-rich fibrin matrix) who had postoperative MRI scans were excluded. Preoperative MRI scans were evaluated for anteroposterior tear size, tendon retraction, tendon length, muscle quality, and MTJ position with respect to the glenoid in the coronal plane. The position of the MTJ was referenced off the glenoid face as either lateral or medial. Postoperative MRI scans were evaluated for healing, tendon length, and MTJ position. Of 42 tears, 36 (86%) healed, with 27 of 31 small to medium tears (87%) and 9 of 11 large to massive tears (82%) healing. Healing occurred in 94% of tears that had a preoperative MTJ lateral to the face of the glenoid but only 56% of tears that had a preoperative MTJ medial to the glenoid face (P = .0135). The measured tendon length increased an average of 14.4 mm in patients whose tears healed compared with shortening by 6.4 mm in patients with tears that did not heal (P < .001). The MTJ lateralized an average of 6.1 mm in patients whose tears healed compared with medializing 1.9 mm in patients whose tears did not heal (P = .026). The overall follow-up period of the study was from April 2005 to September 2014 (113 months). The preoperative MTJ position is predictive of postoperative healing after double-row rotator cuff repair. The position of the MTJ with respect to the glenoid face is a reliable, identifiable marker on MRI scans that can be predictive of healing. Level IV, retrospective review of case series; therapeutic study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. Novel engineered tendon-fibrocartilage-bone composite with cyclic tension for rotator cuff repair.

    PubMed

    Liu, Qian; Hatta, Taku; Qi, Jun; Liu, Haoyu; Thoreson, Andrew R; Amadio, Peter C; Moran, Steven L; Steinmann, Scott P; Gingery, Anne; Zhao, Chunfeng

    2018-05-15

    Surgical repair of rotator cuff tears presents a significant clinical challenge with high failure rates and inferior functional outcomes. Graft augmentation improves repair outcomes, however currently available grafting materials have limitations. While cell-seeded decellularized tendon slices may facilitate cell infiltration, promote tendon incorporation and preserve original mechanical strength, the unique fibrocartilage zone is yet to be successfully reestablished. In this study, we investigated the biological and mechanical properties of an engineered tendon-fibrocartilage-bone composite (TFBC) with cyclic tension (3% strain, 0.2 Hz). Decellularized TFBCs seeded with bone marrow-derived mesenchymal stem cell (BMSCs) sheets and subjected to mechanical stimulation for up to 7 days, were characterized by histology, immunohistochemistry, scanning electron microscopy, mechanical testing, and transcriptional regulation. The decellularized TFBC maintained native enthesis structure and properties. Mechanically stimulated TFBC-BMSC constructs displayed increased cell migration after 7 days of culture compared to static groups. The seeded cell sheet not only integrated well with tendon scaffold but also distributed homogeneously and aligned to the direction of stretch under dynamic culture. Developmental genes were regulated including, scleraxis which was significantly upregulated with mechanical stimulation. The Young's modulus of the cell-seeded constructs was significantly higher compared to the non-cell-seeded controls. In conclusion, the results of this study reveal that the TFBC-BMSC composite provides an ideal multilayer construct for cell seeding and growth, with mechanical preconditioning further enhances cell penetration and differentiation. The BMSC cell sheet revitalized TFBC in conjunction with mechanical stimulation could serve as a novel and primed biological patch to improve rotator cuff repair. This article is protected by copyright. All rights reserved.

  17. Mechanical risk of rotator cuff repair failure during passive movements: A simulation-based study.

    PubMed

    Haering, Diane; Blache, Yoann; Raison, Maxime; Begon, Mickael

    2015-12-01

    Despite improvements in rotator cuff surgery techniques, re-tear rate remains above 20% and increases with tear severity. Mechanical stresses to failure of repaired tendons have been reported. While optimal immobilization postures were proposed to minimize this stress, post-operative rehabilitation protocols have never been assessed with respect to these values. Purpose was to use musculoskeletal simulation to predict when the stress in repaired tendons exceeds safety limits during passive movements. Hence, guidelines could be provided towards safer post-operative exercises. Sixteen healthy participants volunteered in passive three-dimensional shoulder range-of-motion and passive rehabilitation exercises assessment. Stress in all rotator cuff tendons was predicted during each movement by means of a musculoskeletal model using simulations with different type and size of tears. Safety stress thresholds were defined based on repaired tendon loads to failure reported in the literature and used to discriminate safe from unsafe ranges-of-motion. Increased tear size and multiple tendons tear decreased safe range-of-motion. Mostly, glenohumeral elevations below 38°, above 65°, or performed with the arm held in internal rotation cause excessive stresses in most types and sizes of injury during abduction, scaption or flexion. Larger safe amplitudes of elevation are found in scapular plane for supraspinatus alone, supraspinatus plus infraspinatus, and supraspinatus plus subscapularis tears. This study reinforces that passive early rehabilitation exercises could contribute to re-tear due to excessive stresses. Recommendations arising from this study, for instance to keep the arm externally rotated during elevation in case of supraspinatus or supraspinatus plus infraspinatus tear, could help prevent re-tear. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  18. Neglected rupture of the quadriceps tendon in a patient with chronic renal failure (case report and review of the literature).

    PubMed

    Hassani, Zouhir Ameziane; Boufettal, Moncef; Mahfoud, Moustapha; Elyaacoubi, Moradh

    2014-01-01

    Spontaneous ruptures of the quadriceps tendon are infrequent injuries, it is seen primarily in patients with predisposing diseases such as gout, rheumatoid arthritis and chronic renal failure. A 32-year-old man had a history of end stage renal disease and received regular hemodialysis treatment for more than 5 years. He was admitted in our service for total functional impotence of the right lower limb with knee pain after a common fall two months ago. The radiogram showed a ''patella baja" with suprapatellar calcifications. The ultrasound and MRI showed an aspect of rupture of the quadriceps tendon in its proximal end with retraction of 3 cm. Quadriceps tendon repair was performed with a lengthening plasty, and the result was satisfactory after a serial rehabilitation program. The diagnosis of quadriceps tendon ruptures needs more attention in patients with predisposing diseases. They should not be unknown because the treatment of neglected lesions is more difficult. We insist on the early surgical repair associated with early rehabilitation that can guarantee recovery of good active extension.

  19. Repair of full-thickness tendon injury using connective tissue progenitors efficiently derived from human embryonic stem cells and fetal tissues.

    PubMed

    Cohen, Shahar; Leshansky, Lucy; Zussman, Eyal; Burman, Michael; Srouji, Samer; Livne, Erella; Abramov, Natalie; Itskovitz-Eldor, Joseph

    2010-10-01

    The use of stem cells for tissue engineering (TE) encourages scientists to design new platforms in the field of regenerative and reconstructive medicine. Human embryonic stem cells (hESC) have been proposed to be an important cell source for cell-based TE applications as well as an exciting tool for investigating the fundamentals of human development. Here, we describe the efficient derivation of connective tissue progenitors (CTPs) from hESC lines and fetal tissues. The CTPs were significantly expanded and induced to generate tendon tissues in vitro, with ultrastructural characteristics and biomechanical properties typical of mature tendons. We describe a simple method for engineering tendon grafts that can successfully repair injured Achilles tendons and restore the ankle joint extension movement in mice. We also show the CTP's ability to differentiate into bone, cartilage, and fat both in vitro and in vivo. This study offers evidence for the possibility of using stem cell-derived engineered grafts to replace missing tissues, and sets a basic platform for future cell-based TE applications in the fields of orthopedics and reconstructive surgery.

  20. The flexor digitorum profundus "demi-tendon"--a new technique for passage of the flexor profundus tendon through the A4 pulley.

    PubMed

    Elliot, D; Khandwala, A R; Ragoowansi, R

    2001-10-01

    The flexor digitorum profundus (FDP) tendon may retract after avulsion or division in Zone 1. When treatment has been delayed, the oedematous tendon can be too swollen to pass freely through the A4 pulley. We present a new technique for dealing with this situation which depends on the "double-barrelled" nature of the distal part of the FDP tendon. One half of the tendon is excised longitudinally and the remaining "demi-tendon" is passed through the intact A4 pulley to allow tendon repair or re-attachment. This technique has been used in six cases in which passage of the FDP tendon through the A4 pulley would otherwise have been impossible. Copyright 2001 The British Society for Surgery of the Hand.

  1. Application of a novel Kalman filter based block matching method to ultrasound images for hand tendon displacement estimation.

    PubMed

    Lai, Ting-Yu; Chen, Hsiao-I; Shih, Cho-Chiang; Kuo, Li-Chieh; Hsu, Hsiu-Yun; Huang, Chih-Chung

    2016-01-01

    Information about tendon displacement is important for allowing clinicians to not only quantify preoperative tendon injuries but also to identify any adhesive scaring between tendon and adjacent tissue. The Fisher-Tippett (FT) similarity measure has recently been shown to be more accurate than the Laplacian sum of absolute differences (SAD) and Gaussian sum of squared differences (SSD) similarity measures for tracking tendon displacement in ultrasound B-mode images. However, all of these similarity measures can easily be influenced by the quality of the ultrasound image, particularly its signal-to-noise ratio. Ultrasound images of injured hands are unfortunately often of poor quality due to the presence of adhesive scars. The present study investigated a novel Kalman-filter scheme for overcoming this problem. Three state-of-the-art tracking methods (FT, SAD, and SSD) were used to track the displacements of phantom and cadaver tendons, while FT was used to track human tendons. These three tracking methods were combined individually with the proposed Kalman-filter (K1) scheme and another Kalman-filter scheme used in a previous study to optimize the displacement trajectories of the phantom and cadaver tendons. The motion of the human extensor digitorum communis tendon was measured in the present study using the FT-K1 scheme. The experimental results indicated that SSD exhibited better accuracy in the phantom experiments, whereas FT exhibited better performance for tracking real tendon motion in the cadaver experiments. All three tracking methods were influenced by the signal-to-noise ratio of the images. On the other hand, the K1 scheme was able to optimize the tracking trajectory of displacement in all experiments, even from a location with a poor image quality. The human experimental data indicated that the normal tendons were displaced more than the injured tendons, and that the motion ability of the injured tendon was restored after appropriate rehabilitation sessions. The obtained results show the potential for applying the proposed FT-K1 method in clinical applications for evaluating the tendon injury level after metacarpal fractures and assessing the recovery of an injured tendon during rehabilitation.

  2. Richly innervated soft tissues covering the superficial aspect of the extensor origin in patients with chronic painful tennis elbow - Implication for treatment?

    PubMed

    Spang, C; Alfredson, H

    2017-06-01

    Tennis elbow is difficult to treat. The results of surgical treatments are not convincing. Treatment studies on Achilles and patellar tendinopathy targeting the richly innervated and vascularized soft tissues outside the tendon have shown promising outcomes. The innervation patterns in the fibrous/fatty tissues superficially to the elbow extensor origin have not been clarified. Nine tissue specimens from the fibrous/fatty tissue covering the extensor origin was taken from seven patients (mean age: 45 years) undergoing surgical treatment for chronic painful tennis elbow. The specimens were stained for morphology (haematoxylin and eosin, H and E) and immunohistochemically for general nerve marker protein gene product 9.5 (PGP 9.5) and markers for sympathetic (tyrosine hydroxylase, TH) and sensory nerve fibres (calcitonin gene-related peptide, CGRP). All specimens contained multiple blood vessels and nerve structures indicated by morphology and immunoreactions. There was a frequent occurrence of TH reactions, especially peri-vascularly, but also in nerve fascicles. Immunoreactions for CGRP were seen in nerve fascicles and isolated nerve fibres. The results provide new information on the innervation patterns of the superficial tissues of the extensor origin and their potential as source of tennis elbow pain. IV.

  3. Richly innervated soft tissues covering the superficial aspect of the extensor origin in patients with chronic painful tennis elbow – Implication for treatment?

    PubMed Central

    Spang, C.; Alfredson, H.

    2017-01-01

    Background: Tennis elbow is difficult to treat. The results of surgical treatments are not convincing. Treatment studies on Achilles and patellar tendinopathy targeting the richly innervated and vascularized soft tissues outside the tendon have shown promising outcomes. The innervation patterns in the fibrous/fatty tissues superficially to the elbow extensor origin have not been clarified. Methods: Nine tissue specimens from the fibrous/fatty tissue covering the extensor origin was taken from seven patients (mean age: 45 years) undergoing surgical treatment for chronic painful tennis elbow. The specimens were stained for morphology (haematoxylin & eosin, H&E) and immunohistochemically for general nerve marker protein gene product 9.5 (PGP 9.5) and markers for sympathetic (tyrosine hydroxylase, TH) and sensory nerve fibres (calcitonin gene-related peptide, CGRP). Results: All specimens contained multiple blood vessels and nerve structures indicated by morphology and immunoreactions. There was a frequent occurrence of TH reactions, especially peri-vascularly, but also in nerve fascicles. Immunoreactions for CGRP were seen in nerve fascicles and isolated nerve fibres. Conclusion: The results provide new information on the innervation patterns of the superficial tissues of the extensor origin and their potential as source of tennis elbow pain. Level of Evidence: IV. PMID:28574416

  4. Fluoroquinolones impair tendon healing in a rat rotator cuff repair model: a preliminary study.

    PubMed

    Fox, Alice J S; Schär, Michael O; Wanivenhaus, Florian; Chen, Tony; Attia, Erik; Binder, Nikolaus B; Otero, Miguel; Gilbert, Susannah L; Nguyen, Joseph T; Chaudhury, Salma; Warren, Russell F; Rodeo, Scott A

    2014-12-01

    Recent studies suggest that fluoroquinolone antibiotics predispose tendons to tendinopathy and/or rupture. However, no investigations on the reparative capacity of tendons exposed to fluoroquinolones have been conducted. Fluoroquinolone-treated animals will have inferior biochemical, histological, and biomechanical properties at the healing tendon-bone enthesis compared with controls. Controlled laboratory study. Ninety-two rats underwent rotator cuff repair and were randomly assigned to 1 of 4 groups: (1) preoperative (Preop), whereby animals received fleroxacin for 1 week preoperatively; (2) pre- and postoperative (Pre/Postop), whereby animals received fleroxacin for 1 week preoperatively and for 2 weeks postoperatively; (3) postoperative (Postop), whereby animals received fleroxacin for 2 weeks postoperatively; and (4) control, whereby animals received vehicle for 1 week preoperatively and for 2 weeks postoperatively. Rats were euthanized at 2 weeks postoperatively for biochemical, histological, and biomechanical analysis. All data were expressed as mean ± standard error of the mean (SEM). Statistical comparisons were performed using either 1-way or 2-way ANOVA, with P < .05 considered significant. Reverse transcriptase quantitative polymerase chain reaction (RTqPCR) analysis revealed a 30-fold increase in expression of matrix metalloproteinase (MMP)-3, a 7-fold increase in MMP-13, and a 4-fold increase in tissue inhibitor of metalloproteinases (TIMP)-1 in the Pre/Postop group compared with the other groups. The appearance of the healing enthesis in all treated animals was qualitatively different than that in controls. The tendons were friable and atrophic. All 3 treated groups showed significantly less fibrocartilage and poorly organized collagen at the healing enthesis compared with control animals. There was a significant difference in the mode of failure, with treated animals demonstrating an intrasubstance failure of the supraspinatus tendon during testing. In contrast, only 1 of 10 control samples failed within the tendon substance. The healing enthesis of the Pre/Postop group displayed significantly reduced ultimate load to failure compared with the Preop, Postop, and control groups. There was no significant difference in load to failure in the Preop group compared with the Postop group. Pre/Postop animals demonstrated significantly reduced cross-sectional area compared with the Postop and control groups. There was also a significant reduction in area between the Preop and control groups. In this preliminary study, fluoroquinolone treatment negatively influenced tendon healing. These findings indicate that there was an active but inadequate repair response that has potential clinical implications for patients who are exposed to fluoroquinolones before tendon repair surgery. © 2014 The Author(s).

  5. Transtendon, Double-Row, Transosseous-Equivalent Arthroscopic Repair of Partial-Thickness, Articular-Surface Rotator Cuff Tears

    PubMed Central

    Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.

    2014-01-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness. PMID:25473606

  6. Transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears.

    PubMed

    Dilisio, Matthew F; Miller, Lindsay R; Higgins, Laurence D

    2014-10-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness.

  7. Vitamin D and the immunomodulation of rotator cuff injury

    PubMed Central

    Dougherty, Kaitlin A; Dilisio, Matthew F; Agrawal, Devendra K

    2016-01-01

    Tendon-to-bone healing after rotator cuff repair surgery has a failure rate of 20%–94%. There has been a recent interest to determine the factors that act as determinants between successful and unsuccessful rotator cuff repair. Vitamin D level in patients is one of the factors that have been linked to bone and muscle proliferation and healing, and it may have an effect on tendon-to-bone healing. The purpose of this article is to critically review relevant published research that relates to the effect of vitamin D on rotator cuff tears and subsequent healing. A review of the literature was conducted to identify all studies that investigate the relationship between vitamin D and tendon healing, in addition to its mechanism of action. The data were then analyzed in order to summarize what is currently known about vitamin D, rotator cuff pathology, and tendon-to-bone healing. The activated metabolite of vitamin D, 1α,25-dihydroxyvitamin D3, affects osteoblast proliferation and differentiation. Likewise, vitamin D plays a significant role in the tendon-to-bone healing process by increasing the bone mineral density and strengthening the skeletal muscles. The 1α,25-dihydroxyvitamin D3 binds to vitamin D receptors on myocytes to stimulate growth and proliferation. The form of vitamin D produced by the liver, calcifediol, is a key initiator of the myocyte healing process by moving phosphate into myocytes, which improves function and metabolism. Investigation into the effect of vitamin D on tendons has been sparse, but limited studies have been promising. Matrix metalloproteinases play an active role in remodeling the extracellular matrix (ECM) of tendons, particularly deleterious remodeling of the collagen fibers. Also, the levels of transforming growth factor-β3 positively influence the success of the surgery for rotator cuff repair. In the tendon-to-bone healing process, vitamin D has been shown to successfully influence bone and muscle healing, but more research is needed to delve into the mechanisms of vitamin D as a factor in skeletal tendon health and healing. PMID:27366101

  8. Incidence and treatment of postoperative stiffness following arthroscopic rotator cuff repair.

    PubMed

    Huberty, David P; Schoolfield, John D; Brady, Paul C; Vadala, Antonio P; Arrigoni, Paolo; Burkhart, Stephen S

    2009-08-01

    The purpose of this study was to determine the incidence of clinically significant postoperative stiffness following arthroscopic rotator cuff repair. This study also sought to determine the clinical and surgical factors that were associated with higher rates of postoperative stiffness. Finally, we analyzed the result of arthroscopic lysis of adhesions and capsular release for treatment of patients who developed refractory postoperative stiffness 4 to 19 months (median, 8 months) following arthroscopic rotator cuff repair. A retrospective review of a consecutive series of arthroscopic rotator cuff repairs was conducted. During a 3-year time period, the senior author (S.S.B.) performed 489 arthroscopic rotator cuff repairs. The operative indications, technique of the rotator cuff repair, and the rehabilitation protocol were essentially unchanged during this time period. Demographic data, comorbid medical conditions, rotator cuff tear description, technique of repair, and concomitant surgical procedures were evaluated for their effect on stiffness. All office evaluations were reviewed to determine the pre- and postoperative motion, pain scores, functional strength, and patient satisfaction. Patients who were dissatisfied because of the development of postoperative stiffness underwent secondary arthroscopic lysis of adhesions. The final result of the secondary lysis of adhesions and capsular release were analyzed. In total, 24 patients (4.9%) were dissatisfied with the result of their procedure because of the development of postoperative stiffness, which was more likely (P < .05) to develop in patients with Workers' Compensation insurance (8.6%), patients younger than 50 years of age (8.6%), those with a coexisting diagnosis of calcific tendonitis (16.7%) or adhesive capsulitis (15.0%) requiring additional postoperative therapy, partial articular-sided tendon avulsion (PASTA) type rotator cuff tear (13.5%), or concomitant labral repair (11.0%). Patients with concomitant coracoplasty (2.3%) or tears larger in size and/or involving more tendons were less likely (P < .05) to develop postoperative stiffness. Among 90 patients positive for selected risk factors (adhesive capsulitis, excision of calcific deposits, single-tendon repair, PASTA repair, or any labral repair without a concomitant coracoplasty), 12 (13.3%) developed postoperative stiffness (P < .001). This overall clinical risk factor combined with Workers' Compensation insurance identified 16 of the 24 cases resulting in a sensitivity of 66.7% and a specificity of 64.5%. All 24 patients who experienced postoperative stiffness elected to undergo arthroscopic lysis of adhesions and capsular release, which was performed from 4 to 19 months (median, 8 months) after the rotator cuff repair. During second-look arthroscopy, 23 patients (95.8%) were noted to have complete healing of the original pathology. Following capsular release, all 24 patients were satisfied with the overall result of their treatment. In a series of 489 consecutive arthroscopic rotator cuff repairs, we found that 24 patients (4.9%) developed postoperative stiffness. Risk factors for postoperative stiffness were calcific tendinitis, adhesive capsulitis, single-tendon cuff repair, PASTA repair, being under 50 years of age, and having Workers' Compensation insurance. Twenty-three of 24 patients (95.8%) showed complete healing of the rotator cuff. Arthroscopic release resulted in normal motion in all cases. Level IV, therapeutic case series.

  9. Positive force feedback in human walking

    PubMed Central

    Grey, Michael J; Nielsen, Jens Bo; Mazzaro, Nazarena; Sinkjær, Thomas

    2007-01-01

    The objective of this study was to determine if load receptors contribute to the afferent-mediated enhancement of ankle extensor muscle activity during the late stance phase of the step cycle. Plantar flexion perturbations were presented in late stance while able-bodied human subjects walked on a treadmill that was declined by 4%, inclined by 4% or held level. The plantar flexion perturbation produced a transient, but marked, presumably spinally mediated decrease in soleus EMG that varied directly with the treadmill inclination. Similarly, the magnitude of the control step soleus EMG and Achilles' tendon force also varied directly with the treadmill inclination. In contrast, the ankle angular displacement and velocity were inversely related to the treadmill inclination. These results suggest that Golgi tendon organ feedback, via the group Ib pathway, is reduced when the muscle–tendon complex is unloaded by a rapid plantar flexion perturbation in late stance phase. The changes in the unload response with treadmill inclination suggest that the late stance phase soleus activity may be enhanced by force feedback. PMID:17331984

  10. Age-related degeneration in leg-extensor muscle-tendon units decreases recovery performance after a forward fall: compensation with running experience.

    PubMed

    Karamanidis, Kiros; Arampatzis, Adamantios

    2007-01-01

    The goals of this study were to investigate whether the lower muscle-tendon units (MTUs) capacities in older affect their ability to recover balance with a single-step after a fall, and to examine whether running experience enhances and protects this motor skill in young and old adults. The investigation was conducted on 30 older and 19 younger divided into two subgroups: runners versus non-active. In previous studies we documented that the older had lower leg extensor muscle strength and tendon stiffness while running had no effect on MTUs capacities. The current study examined recovery mechanics of the same individuals after an induced forward fall. Younger were better able to recover balance with a single-step compared to older (P < 0.001); this ability was associated with a more effective body configuration at touchdown (more posterior COM position relative to the recovery foot, P <0.001). MTUs capacities classified 88.6% of the subjects into single- or multiple-steppers. Runners showed a superior ability to recover balance with a single-step (P < 0.001) compared to non-active subjects due to a more effective mechanical response during the stance phase (greater knee joint flexion, P <0.05). We concluded that the age-related degeneration of the MTUs significantly diminished the older adults' ability to restore balance with a single-step. Running seems to enhance and protect this motor skill. We suggested that runners, due to their running experience, could update the internal representation of mechanisms responsible for the control of dynamic stability during a forward fall and, thus, were able to restore balance more often with a single-step compared to the non-active subjects.

  11. Single-Versus Double-Row Arthroscopic Rotator Cuff Repair in Massive Tears

    PubMed Central

    Wang, EnZhi; Wang, Liang; Gao, Peng; Li, ZhongJi; Zhou, Xiao; Wang, SongGang

    2015-01-01

    Background It is a challenge for orthopaedic surgeons to treat massive rotator cuff tears. The optimal management of massive rotator cuff tears remains controversial. Therefore, the goal of this study was to compare arthroscopic single- versus double-row rotator cuff repair with a larger sample size. Material/Methods Of the subjects with massive rotator cuff tears, 146 were treated using single-row repair, and 102 were treated using double-row repair. Pre- and postoperative functional outcomes and radiographic images were collected. The clinical outcomes were evaluated for a minimum of 2 years. Results No significant differences were shown between the groups in terms of functional outcomes. Regarding the integrity of the tendon, a lower rate of post-treatment retear was observed in patients who underwent double-row repair compared with single-row repair. Conclusions The results suggest that double-row repair is relatively superior in shoulder ROM and the strength of tendon compared with single-row repair. Future studies involving more patients in better-designed randomized controlled trials will be required. PMID:26017641

  12. Sensitivity of physical examination versus arthroscopy in diagnosing subscapularis tendon injury.

    PubMed

    Faruqui, Sami; Wijdicks, Coen; Foad, Abdullah

    2014-01-01

    The purpose of this study was to examine the accuracy of physical examination in the detection of subscapularis tendon tears and compare it with the gold standard of arthroscopy to determine whether clinical examination can reliably predict the presence of subscapularis tendon tears. This was a retrospective analysis of 52 patients (52 shoulders) who underwent arthroscopic subscapularis tendon repairs between September 2008 and April 2012. Positive findings on any combination of the belly press, lift-off, and bear hug tests constituted a positive physical examination result. There was a positive finding on physical examination in 42 of 52 patients. The sensitivity of the physical examination as a whole was 81%. The literature has shown that the belly press, bear hug, and lift-off tests are specific to the subscapularis tendon. To the authors’ knowledge, this is the first study to evaluate the sensitivity of these 3 separate clinical tests as a composite. Knowledge regarding the sensitivity of the subscapularis-specific physical examination as a composite can lead practitioners to implement all 3 components, even when 1 test has a negative finding, thus promoting a more thorough physical examination. Because unrepaired subscapularis tendon tears can result in poor outcomes in the repair of other rotator cuff tendons, a complete physical examination would be beneficial to patients with shoulder pathology. The authors conclude that physical examination, when performed consistently by an experienced practitioner, can reliably predict the presence of subscapularis tendon tears.

  13. Clinical Outcomes of Modified Mason-Allen Single-Row Repair for Bursal-Sided Partial-Thickness Rotator Cuff Tears: Comparison With the Double-Row Suture-Bridge Technique.

    PubMed

    Shin, Sang-Jin; Kook, Seung-Hwan; Rao, Nandan; Seo, Myeong-Jae

    2015-08-01

    Various repair techniques have been reported for the operative treatment of bursal-sided partial-thickness rotator cuff tears. Recently, arthroscopic single-row repair using a modified Mason-Allen technique has been introduced. The arthroscopic, modified Mason-Allen single-row technique with preservation of the articular-sided tendon provides satisfactory clinical outcomes and similar results to the double-row suture-bridge technique after conversion of a partial-thickness tear to a full-thickness tear. Cohort study; Level of evidence, 3. A retrospective study was conducted on 84 consecutive patients with symptomatic, bursal-sided partial-thickness rotator cuff tears involving more than 50% thickness of the tendon. A total of 47 patients were treated by the modified Mason-Allen single-row repair technique, preserving the articular-sided tendon, and 37 patients were treated by the double-row suture-bridge repair technique after conversion to a full-thickness tear. The clinical and functional outcomes were evaluated using the American Shoulder and Elbow Surgeons (ASES) and Constant scores and a visual analog scale (VAS) for pain and satisfaction of patients. Magnetic resonance imaging (MRI) was used to analyze the integrity of tendons at 6-month follow-up. Patients were followed up for a mean of 32.5 months. In the 47 patients treated with the modified Mason-Allen suture technique, the VAS score decreased from a preoperative mean of 5.3 ± 0.3 to 0.9 ± 0.5 at the time of final follow-up. There was a statistically significant increase in the mean ASES score (from 45.4 ± 2.9 to 88.6 ± 4.5) and mean Constant score (from 66.9 ± 2.6 to 88.1 ± 2.4) (P < .001). Four of 47 patients (8.5%) demonstrated retears at 6-month postoperative MRI. There was no statistical difference in terms of functional outcomes and the retear rate compared with those of patients with the suture-bridge repair technique (3 patients, 8.1%). However, the mean number of suture anchors used in the patients with modified Mason-Allen suture repair (1.2 ± 0.4) was significantly fewer than that in the patients with suture-bridge repair (3.2 ± 0.4) (P < .01). The modified Mason-Allen single-row repair technique that preserved the articular-sided tendon provided satisfactory clinical outcomes in patients with symptomatic, bursal-sided partial-thickness rotator cuff tears. Despite a fewer number of suture anchors, the shoulder functional outcomes and retear rate in patients after modified Mason-Allen repair were comparable with those of patients who underwent double-row suture-bridge repair. Therefore, the modified Mason-Allen single-row repair technique using a triple-loaded suture anchor can be considered as an effective treatment in patients with bursal-sided partial-thickness rotator cuff tears. © 2015 The Author(s).

  14. The Fate of the Iliopsoas Muscle in Long-term Follow-up After Open Reduction With a Medial Approach in Developmental Dysplasia of the Hip. Part 2: Isokinetic Muscle Strength Evaluation.

    PubMed

    Yilmaz, Serdar; Aksahin, Ertugrul; Ersoz, Murat; Bicimoglu, Ali

    2017-09-01

    The impact on long-term weakness of hip flexion of complete iliopsoas tenotomy during open reduction of developmental hip dysplasia with a medial approach has not yet been fully clarified. The purpose of this study was to investigate the isokinetic muscle strength (IMS) of hip flexor and extensor muscles in these patients and also to analyze the effect of spontaneous reattachment of the iliopsoas muscle on IMS measurements. The study included 20 patients. Earlier magnetic resonance imaging examination of all the patients revealed spontaneous reattachment of the iliopsoas in 18 (90%) patients. IMS measurements were performed at 60 and 150 degrees/s. The peak torque, total work (TW), average power (AP), work fatigue, and agonist to antagonist muscle ratio of the operated and nonoperated hips were recorded separately for flexors and extensors. The effect of iliopsoas reattachment on IMS was also evaluated. The mean follow-up period was 16.65±2.16 (13 to 20) years. Total work (P=0.013) and average power (P=0.009) of the flexor muscles and work fatigue of the extensor muscles (P=0.030) of the operated hip were significantly decreased when compared with the nonoperated hips at 150 degrees/s. There was no significant difference between the flexor muscles of the operated and nonoperated hips (P<0.05) at 60 degrees/s and extensor muscles (P<0.05) at 150 degrees/s. In addition, patients without reattachment had lower IMS in the operated hips. Flexor muscle strength was decreased in the operated hip against low resistance in long-term follow-up after iliopsoas tenotomy. This may reflect that hip muscle strength was decreased after prolonged activities such as sports. However, in forceful activities flexor muscle strength was retained due to iliopsoas reattachment. On the basis of this study we thought that spontaneous reattachment of the iliopsoas tendon substantially preserves muscle strength. Nonetheless possible efforts should be made to surgically reattach the psoas tendon to preserve strength of the muscle. Therapeutic level IV.

  15. A Clinical, Biological, and Biomaterials Perspective into Tendon Injuries and Regeneration

    PubMed Central

    Walden, Grace; Liao, Xin; Donell, Simon; Raxworthy, Mike J.; Riley, Graham P.

    2017-01-01

    Tendon injury is common and debilitating, and it is associated with long-term pain and ineffective healing. It is estimated to afflict 25% of the adult population and is often a career-ending disease in athletes and racehorses. Tendon injury is associated with high morbidity, pain, and long-term suffering for the patient. Due to the low cellularity and vascularity of tendon tissue, once damage has occurred, the repair process is slow and inefficient, resulting in mechanically, structurally, and functionally inferior tissue. Current treatment options focus on pain management, often being palliative and temporary and ending in reduced function. Most treatments available do not address the underlying cause of the disease and, as such, are often ineffective with variable results. The need for an advanced therapeutic that addresses the underlying pathology is evident. Tissue engineering and regenerative medicine is an emerging field that is aimed at stimulating the body's own repair system to produce de novo tissue through the use of factors such as cells, proteins, and genes that are delivered by a biomaterial scaffold. Successful tissue engineering strategies for tendon regeneration should be built on a foundation of understanding of the molecular and cellular composition of healthy compared with damaged tendon, and the inherent differences seen in the tissue after disease. This article presents a comprehensive clinical, biological, and biomaterials insight into tendon tissue engineering and regeneration toward more advanced therapeutics. PMID:27596929

  16. Pectoralis Major Repair With Unicortical Button Fixation And Suture Tape.

    PubMed

    Sanchez, Anthony; Ferrari, Marcio B; Frangiamore, Salvatore J; Sanchez, George; Kruckeberg, Bradley M; Provencher, Matthew T

    2017-06-01

    Although injuries of the pectoralis major muscle are generally uncommon, ruptures of the pectoralis major are occasionally seen in younger, more active patients who participate in weightlifting activities. These injuries usually occur during maximal contraction of the muscle, while in extension and external rotation. In the case of a rupture, operative treatment is advocated especially in young, active patients regardless of the chronicity of the injury. Various surgical techniques for reattachment of the avulsed tendon have been described, but bone tunnel and suture anchor repair techniques are most widely used. In this Technical Note, we present our preferred technique for acute pectoralis major rupture repair involving use of cortical buttons for tendon stump-to-bone fixation.

  17. Does Early Versus Delayed Active Range of Motion Affect Rotator Cuff Healing After Surgical Repair? A Systematic Review and Meta-analysis.

    PubMed

    Kluczynski, Melissa A; Isenburg, Maureen M; Marzo, John M; Bisson, Leslie J

    2016-03-01

    The timing of passive range of motion (ROM) after surgical repair of the rotator cuff (RC) has been shown to affect healing. However, it is unknown if early or delayed active ROM affects healing. To determine whether early versus delayed active ROM affects structural results of RC repair surgery. Systematic review and meta-analysis. A systematic review of articles published between January 2004 and April 2014 was conducted. Structural results were compared for early (<6 weeks after surgery) versus delayed (≥6 weeks after surgery) active ROM using chi-square and Fisher exact tests, as well as relative risks (RRs) and 95% CIs. The analyses were stratified by tear size and repair method. A total of 37 studies (2251 repairs) were included in the analysis, with 10 (649 repairs) in the early group and 27 (1602 repairs) in the delayed group. For tears ≤3 cm, the risk of a structural tendon defect was higher in the early versus delayed group for transosseous plus single-row suture anchor repairs (39.7% vs 24.3%; RR, 1.63 [95% CI, 1.28-2.08]). For tears >3 cm, the risk of a structural tendon defect was higher in the early versus delayed group for suture bridge repairs (48% vs 17.5%; RR, 2.74 [95% CI, 1.59-4.73]) and all repair methods combined (40.5% vs 26.7%; RR, 1.52 [95% CI, 1.17-1.97]). For tears >5 cm, the risk of structural tendon defect was higher in the early versus delayed group for suture bridge repairs (100% vs 16.7%; RR, 6.00 [95% CI, 1.69-21.26]). There were no statistically significant associations for tears measuring ≤1, 1-3, or 3-5 cm. Early active ROM was associated with increased risk of a structural defect for small and large RC tears, and thus might not be advisable after RC repair. © 2015 The Author(s).

  18. Does microvascularization of the footprint play a role in rotator cuff healing of the shoulder?

    PubMed

    Bonnevialle, Nicolas; Bayle, Xavier; Faruch, Marie; Wargny, Matthieu; Gomez-Brouchet, Anne; Mansat, Pierre

    2015-08-01

    The aim of the study was to evaluate the relationship between bone microvascularization of the footprint and tendon integrity after rotator cuff repair of the shoulder. Forty-eight patients (mean age, 59 years; ±7.9) with a chronic rotator cuff tear underwent a tendon repair with a single-row technique and were studied prospectively. A core obtained from the footprint during the procedure allowed determination of the bone's microvascularization with an immunohistochemistry technique using anti-CD34 antibodies. Clinical evaluation was performed at a minimum of 12-month follow-up, and rotator cuff integrity was assessed with ultrasound according to Sugaya's classification. At a mean follow-up of 13 months, the Constant score improved from 40 to 75 points; American Shoulder and Elbow Surgeons score, from 59 to 89 points; and subjective shoulder value, from 38% to 83% (P < .001). Ultrasound identified 18 patients with Sugaya type I healing, 27 patients with type II, and 3 patients with type IV. No patients showed Sugaya type III or V repairs. The rate of microvascularization of the footprint was 15.6%, 13.9%, and 4.2% for type I, II, and IV tendon integrity, respectively (I vs. II, P = .22; II vs. IV, P = .02; I vs. IV, P = .0022). Patients with a history of corticosteroid injection had a lower rate of microvascularization than the others (10.3% vs. 16.2%; P = .03). Even if overall satisfactory clinical outcomes are achieved after a rotator cuff repair, bone microvascularization of the footprint plays a role in rotator cuff healing. A lower rate of microvessels decreases the tendon integrity and healing potential after repair. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. Stability of double-row rotator cuff repair is not adversely affected by scaffold interposition between tendon and bone.

    PubMed

    Beitzel, Knut; Chowaniec, David M; McCarthy, Mary Beth; Cote, Mark P; Russell, Ryan P; Obopilwe, Elifho; Imhoff, Andreas B; Arciero, Robert A; Mazzocca, Augustus D

    2012-05-01

    Rotator cuff reconstructions may be improved by adding growth factors, cells, or other biologic factors into the repair zone. This usually requires a biological carrier (scaffold) to be integrated into the construct and placed in the area of tendon-to-bone healing. This needs to be done without affecting the constructs mechanics. Hypothesis/ The hypothesis was that scaffold placement, as an interposition, has no adverse effects on biomechanical properties of double-row rotator cuff repair. The purpose of this study was to examine the effect of scaffold interposition on the initial strength of rotator cuff repairs. Controlled laboratory study. Twenty-five fresh-frozen shoulders (mean age: 65.5 ± 8.9 years) were randomly assigned to 5 groups. Groups were chosen to represent a broad spectrum of commonly used scaffold types: (1) double-row repair without augmentation, (2) double-row repair with interposition of a fibrin clot (Viscogel), (3) double-row repair with interposition of a collagen scaffold (Mucograft) between tendon and bone, (4) double-row repair with interposition of human dermis patch (ArthroFlex) between tendon and bone, and (5) double-row repair with human dermis patch (ArthroFlex) placed on top of the repair. Cyclic loading to measure displacement was performed to 3000 cycles at 1 Hz with an applied 10- to 100-N load. The ultimate load to failure was determined at a rate of 31 mm/min. There were no significant differences in mean displacement under cyclic loading, slope, or energy absorbed to failure between all groups (P = .128, P = .981, P = .105). Ultimate load to failure of repairs that used the collagen patch as an interposition (573.3 ± 75.6 N) and a dermis patch on top of the reconstruction (575.8 ± 22.6 N) was higher compared with the repair without a scaffold (348.9 ± 98.8 N; P = .018 and P = .025). No significant differences were found for repairs with the fibrin clot as an interposition (426.9 ± 103.6 N) and the decellularized dermis patch as an interposition (469.9 ± 148.6 N; P = .73 and P = .35). Scaffold augmentation did not adversely affect the zero time strength of the tested standard double-row rotator cuff repairs. An increased ultimate load to failure was observed for 2 of the augmentation methods (collagen patch as an interposition and decellularized dermis patch on top of the reconstruction) compared with the nonaugmented repairs. Scaffolds intended for application of growth factors or cellular components in a repair situation did not adversely jeopardize the stability of the operative construct.

  20. Beneficial Effects of Autologous Bone Marrow-Derived Mesenchymal Stem Cells in Naturally Occurring Tendinopathy

    PubMed Central

    Smith, Roger Kenneth Whealands; Werling, Natalie Jayne; Dakin, Stephanie Georgina; Alam, Rafiqul; Goodship, Allen E.; Dudhia, Jayesh

    2013-01-01

    Tendon injuries are a common age-related degenerative condition where current treatment strategies fail to restore functionality and normal quality of life. This disease also occurs naturally in horses, with many similarities to human tendinopathy making it an ideal large animal model for human disease. Regenerative approaches are increasingly used to improve outcome involving mesenchymal stem cells (MSCs), supported by clinical data where injection of autologous bone marrow derived MSCs (BM-MSCs) suspended in marrow supernatant into injured tendons has halved the re-injury rate in racehorses. We hypothesized that stem cell therapy induces a matrix more closely resembling normal tendon than the fibrous scar tissue formed by natural repair. Twelve horses with career-ending naturally-occurring superficial digital flexor tendon injury were allocated randomly to treatment and control groups. 1X107 autologous BM-MSCs suspended in 2 ml of marrow supernatant were implanted into the damaged tendon of the treated group. The control group received the same volume of saline. Following a 6 month exercise programme horses were euthanized and tendons assessed for structural stiffness by non-destructive mechanical testing and for morphological and molecular composition. BM-MSC treated tendons exhibited statistically significant improvements in key parameters compared to saline-injected control tendons towards that of normal tendons and those in the contralateral limbs. Specifically, treated tendons had lower structural stiffness (p<0.05) although no significant difference in calculated modulus of elasticity, lower (improved) histological scoring of organisation (p<0.003) and crimp pattern (p<0.05), lower cellularity (p<0.007), DNA content (p<0.05), vascularity (p<0.03), water content (p<0.05), GAG content (p<0.05), and MMP-13 activity (p<0.02). Treatment with autologous MSCs in marrow supernatant therefore provides significant benefits compared to untreated tendon repair in enhancing normalisation of biomechanical, morphological, and compositional parameters. These data in natural disease, with no adverse findings, support the use of this treatment for human tendon injuries. PMID:24086616

  1. Optimizing pressurized contact area in rotator cuff repair: the diamondback repair.

    PubMed

    Burkhart, Stephen S; Denard, Patrick J; Obopilwe, Elifho; Mazzocca, Augustus D

    2012-02-01

    The purpose of this study was to compare tendon-bone footprint contact area over time under physiologic loads for 4 different rotator cuff repair techniques: single row (SR), triangle double row (DR), chain-link double row (CL), and diamondback double row (DBK). A supraspinatus tear was created in 28 human cadavers. Tears were fixed with 1 of 4 constructs: SR, DR, CL, or DBK. Immediate post-repair measurements of pressurized contact area were taken in neutral rotation and 0° of abduction. After a static tensile load, pressurized contact area was observed over a 160-minute period after repair. Cyclic loading was then performed. The DBK repair had the highest pressurized contact area initially, as well as the highest pressurized contact area and lowest percentage decrease in pressurized contact area after 160 minutes of testing. The DBK repair had significantly larger initial pressurized contact than CL (P = .003) and SR (P = .004) but not DR (P = .06). The DBK technique was the only technique that produced a pressurized contact area that exceeded the native footprint both at initial repair (P = .01) and after 160 minutes of testing (P = .01). DBK had a significantly larger mean pressurized contact area than all the repairs after 160 minutes of testing (P = .01). DBK had a significantly larger post-cyclic loading pressurized contact area than CL (P = .01) and SR (P = .004) but not DR (P = .07). This study showed that a diamondback repair (a modification of the transosseous repair) can significantly increase the rotator cuff pressurized contact area in comparison with other standard rotator cuff repair constructs when there is sufficient tendon mobility to perform a double-row repair without excessive tension on the repair site. The persistent pressurized contact area of a DBK repair may be desirable to enhance healing potential when there is sufficient tendon mobility to perform a double-row repair, particularly for large or massive rotator cuff tears where it is important to optimize footprint area and contact to encourage biologic healing. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. Experiences with sheep as an animal model for shoulder surgery: strengths and shortcomings.

    PubMed

    Turner, A Simon

    2007-01-01

    Sheep (and goats) are a convenient large-animal model for rotator cuff repair because of availability, ease of handling and housing, animal cost, and acceptance to society as a research animal. Tenotomy of the infraspinatus tendon and subsequent reattachment to the proximal humerus is useful to address the biomechanical, histologic, and biochemical processes of rotator cuff repair. Detaching this tendon and immediately reattaching it does not represent the clinical picture but serves as a relatively rapid way to screen different suture anchors, suture patterns, scaffolds, growth factors, and other biologics or a combination of these treatments to enhance the healing process. To minimize spontaneous reattachment and reproduce a chronic rotator cuff injury, the end of the tendon can be covered and then reattached 4 weeks later if bone-to-tendon healing is to be evaluated. This chronic model is useful to understand the biology (degree of muscle atrophy and fatty infiltration) of rotator cuff muscles as well as innovative methods of repair. Close-stall confinement is required during the convalescence in acute and chronic studies. Ultrasound in the awake animal can be used to monitor gap formation and tissue organization. Sheep have also been used to determine whether capsular healing after plication is equivalent to open capsular shift.

  3. Results of operative treatment for recalcitrant retrocalcaneal bursitis and midportion Achilles tendinopathy in athletes.

    PubMed

    Lohrer, Heinz; Nauck, Tanja

    2014-08-01

    The results of operative treatment for recalcitrant midportion Achilles tendinopathy and recalcitrant retrocalcaneal bursitis were evaluated using the patient administered, disease specific, and validated VISA-A-G questionnaire. A cohort of 89 patients was prospectively followed. These patients underwent operations for sport induced midportion Achilles tendinopathy (39 procedures) or retrocalcaneal bursitis (55 procedures). Depending on the individual intraoperative findings the patients of either disease were treated with two respective operative modifications (tendon repair or no tendon repair). Preoperative and follow-up status (3, 6, and 12 months) were investigated using the VISA-A-G questionnaire. Preoperatively, the four groups scored from 37.0 ± 17.6 to 45.9 ± 15.2 (p = 0.376-0.993) on the VISA-A-G questionnaire. Six and 12 months postoperatively, the VISA-A-G scores improved significantly (p < 0.001). Twelve months postoperatively, the groups' scores were not different (p = 0.100-0.952) and ranged from 80.8 ± 17.9 to 90.3 ± 10.6. Retrocalcaneal bursitis and midportion Achilles tendinopathy responded equally well to operative treatment. When repaired, additional tendon lesions did not influence this result. We demand to differentiate not only between midportion Achilles tendinopathy and retrocalcaneal bursitis but also to identify additional Achilles tendon lesions to specifically address these lesions during operative procedures.

  4. Tendon Functional Extracellular Matrix

    PubMed Central

    Screen, H.R.C.; Birk, D.E.; Kadler, K.E.; Ramirez, F; Young, M.F.

    2015-01-01

    This article is one of a series, summarising views expressed at the Orthopaedic Research Society New Frontiers in Tendon Research Conference. This particular article reviews the three workshops held under the “Functional Extracellular Matrix” stream. The workshops focused on the roles of the tendon extracellular matrix, such as performing the mechanical functions of tendon, creating the local cell environment and providing cellular cues. Tendon is a complex network of matrix and cells, and its biological functions are influenced by widely-varying extrinsic and intrinsic factors such as age, nutrition, exercise levels and biomechanics. Consequently, tendon adapts dynamically during development, ageing and injury. The workshop discussions identified research directions associated with understanding cell-matrix interactions to be of prime importance for developing novel strategies to target tendon healing or repair. PMID:25640030

  5. Heterotopic mineralization (ossification or calcification) in tendinopathy or following surgical tendon trauma

    PubMed Central

    O'Brien, Etienne J O; Frank, Cyril B; Shrive, Nigel G; Hallgrímsson, Benedikt; Hart, David A

    2012-01-01

    Heterotopic tendon mineralization (ossification or calcification), which may be a feature of tendinopathy or which may develop following surgical trauma (repair or graft harvest), has not received much attention. The purpose of this article is to review the prevalence, mechanisms and consequences of heterotopic tendon mineralization and to identify the gaps in our current understanding. We focus on endochondral heterotopic ossification and draw on knowledge of the mechanisms of this process in other tissues and conditions. Finally, we introduce a novel murine Achilles tendon needle injury model, which will enable us to further study the mechanisms and biomechanical consequences of tendon mineralization. PMID:22974213

  6. Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on muscle force production in people with spinal cord injury (SCI).

    PubMed

    Bochkezanian, Vanesa; Newton, Robert U; Trajano, Gabriel S; Vieira, Amilton; Pulverenti, Timothy S; Blazevich, Anthony J

    2018-02-13

    Neuromuscular electrical stimulation (NMES) is commonly used in skeletal muscles in people with spinal cord injury (SCI) with the aim of increasing muscle recruitment and thus muscle force production. NMES has been conventionally used in clinical practice as functional electrical stimulation (FES), using low levels of evoked force that cannot optimally stimulate muscular strength and mass improvements, and thus trigger musculoskeletal changes in paralysed muscles. The use of high intensity intermittent NMES training using wide-pulse width and moderate-intensity as a strength training tool could be a promising method to increase muscle force production in people with SCI. However, this type of protocol has not been clinically adopted because it may generate rapid muscle fatigue and thus prevent the performance of repeated high-intensity muscular contractions in paralysed muscles. Moreover, superimposing patellar tendon vibration onto the wide-pulse width NMES has been shown to elicit further increases in impulse or, at least, reduce the rate of fatigue in repeated contractions in able-bodied populations, but there is a lack of evidence to support this argument in people with SCI. Nine people with SCI received two NMES protocols with and without superimposing patellar tendon vibration on different days (i.e. STIM and STIM+vib), which consisted of repeated 30 Hz trains of 58 wide-pulse width (1000 μs) symmetric biphasic pulses (0.033-s inter-pulse interval; 2 s stimulation train; 2-s inter-train interval) being delivered to the dominant quadriceps femoris. Starting torque was 20% of maximal doublet-twitch torque and stimulations continued until torque declined to 50% of the starting torque. Total knee extensor impulse was calculated as the primary outcome variable. Total knee extensor impulse increased in four subjects when patellar tendon vibration was imposed (59.2 ± 15.8%) but decreased in five subjects (- 31.3 ± 25.7%). However, there were no statistically significant differences between these sub-groups or between conditions when the data were pooled. Based on the present results there is insufficient evidence to conclude that patellar tendon vibration provides a clear benefit to muscle force production or delays muscle fatigue during wide-pulse width, moderate-intensity NMES in people with SCI. ACTRN12618000022268 . Date: 11/01/2018. Retrospectively registered.

  7. Biomechanical and magnetic resonance imaging evaluation of a single- and double-row rotator cuff repair in an in vivo sheep model.

    PubMed

    Baums, Mike H; Spahn, Gunter; Buchhorn, Gottfried H; Schultz, Wolfgang; Hofmann, Lars; Klinger, Hans-Michael

    2012-06-01

    To investigate the biomechanical and magnetic resonance imaging (MRI)-derived morphologic changes between single- and double-row rotator cuff repair at different time points after fixation. Eighteen mature female sheep were randomly assigned to either a single-row treatment group using arthroscopic Mason-Allen stitches or a double-row treatment group using a combination of arthroscopic Mason-Allen and mattress stitches. Each group was analyzed at 1 of 3 survival points (6 weeks, 12 weeks, and 26 weeks). We evaluated the integrity of the cuff repair using MRI and biomechanical properties using a mechanical testing machine. The mean load to failure was significantly higher in the double-row group compared with the single-row group at 6 and 12 weeks (P = .018 and P = .002, respectively). At 26 weeks, the differences were not statistically significant (P = .080). However, the double-row group achieved a mean load to failure similar to that of a healthy infraspinatus tendon, whereas the single-row group reached only 70% of the load of a healthy infraspinatus tendon. No significant morphologic differences were observed based on the MRI results. This study confirms that in an acute repair model, double-row repair may enhance the speed of mechanical recovery of the tendon-bone complex when compared with single-row repair in the early postoperative period. Double-row rotator cuff repair enables higher mechanical strength that is especially sustained during the early recovery period and may therefore improve clinical outcome. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  8. Knotless single-row rotator cuff repair: a comparative biomechanical study of 2 knotless suture anchors.

    PubMed

    Efird, Chad; Traub, Shaun; Baldini, Todd; Rioux-Forker, Dana; Spalazzi, Jeffrey P; Davisson, Twana; Hawkins, Monica; McCarty, Eric

    2013-08-01

    The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity. Single-row repairs were performed with either type I (Opus Magnum PI; ArthroCare, Austin, Texas) or type II (ReelX STT; Stryker, Mahwah, New Jersey) knotless suture anchors. The repaired tendon was cycled from 10 to 90 N for 500 cycles, followed by load to failure. Gap formation was measured at 5, 100, 200, 300, 400, and 500 cycles with a video digitizing system. Anchor type or location (anterior or posterior) had no effect on gap formation during cyclic loading regardless of position (anterior, P=.385; posterior, P=.389). Maximum load to failure was significantly greater (P=.018) for repairs performed with type II anchors (288±62 N) compared with type I anchors (179±39 N). Primary failure modes were anchor pullout and tendon tearing for type II anchors and suture slippage through the anchor for type I anchors. The internal ratcheting suture-retention mechanism of type II anchors may have helped this anchor outperform the suture-cinching mechanism of type I anchors by supporting significantly higher loads before failure and minimizing suture slippage, potentially leading to stronger repairs clinically. Copyright 2013, SLACK Incorporated.

  9. Preservation of bursal-sided tendon in partial-thickness articular-sided rotator cuff tears: a novel arthroscopic transtendon anatomic repair technique.

    PubMed

    Shin, Sang-Jin; Jeong, Jae-Hoon; Jeon, Yoon Sang; Kim, Rag Gyu

    2016-12-01

    The purpose of this study was to introduce a novel arthroscopic transtendon anatomic repair technique that spares the intact bursal-sided tendon in articular-sided partial-thickness rotator cuff tears (PTRCT) and to present shoulder functional outcomes in patients with symptomatic articular-sided PCRCT that involves more than 50 % of its thickness after arthroscopic repair using a novel technique. Eighteen patients with symptomatic articular-sided PCRCT involving more than 50 % of the tendon's thickness underwent arthroscopic repair using a devised technique. The devised technique restores only the torn articular portion of the rotator cuff at the anatomical footprint using a suture anchor, and preserves the integrity of the corresponding bursal-sided tendon by tying knots at the most lateral bursal side on the subacromial space. Clinical and functional outcome using ASES and Constant scores were evaluated. The structural integrity of the rotator cuff was evaluated by MRI at 6 months postoperatively. Pain relief and shoulder functional outcomes were encouraging during the recovery phase after operation. ASES (preoperative 54.0 ± 10.3 to postoperative 92.6 ± 8.0), Constant score (61.2 ± 8.5-88.0 ± 5.3), VAS for pain (4.9 ± 2.6-0.6 ± 0.7) improved significantly after arthroscopic transtendon anatomic repair (p < 0.001). No patients had rotator cuff retears on 6-month MRI. No complications related to surgical procedures had occurred. The devised technique of arthroscopic transtendon repair provided satisfactory functional outcomes without postoperative discomforts. This technique minimizes over-tightening of the articular layer and reduces tension mismatches between the articular and bursal layers, which are considered as important factors for improvement of postoperative shoulder motion.

  10. Advances in biologic augmentation for rotator cuff repair

    PubMed Central

    Patel, Sahishnu; Gualtieri, Anthony P.; Lu, Helen H.; Levine, William N.

    2016-01-01

    Rotator cuff tear is a very common shoulder injury that often necessitates surgical intervention for repair. Despite advances in surgical techniques for rotator cuff repair, there is a high incidence of failure after surgery because of poor healing capacity attributed to many factors. The complexity of tendon-to-bone integration inherently presents a challenge for repair because of a large biomechanical mismatch between the tendon and bone and insufficient regeneration of native tissue, leading to the formation of fibrovascular scar tissue. Therefore, various biological augmentation approaches have been investigated to improve rotator cuff repair healing. This review highlights recent advances in three fundamental approaches for biological augmentation for functional and integrative tendon–bone repair. First, the exploration, application, and delivery of growth factors to improve regeneration of native tissue is discussed. Second, applications of stem cell and other cell-based therapies to replenish damaged tissue for better healing is covered. Finally, this review will highlight the development and applications of compatible biomaterials to both better recapitulate the tendon–bone interface and improve delivery of biological factors for enhanced integrative repair. PMID:27750374

  11. Transfer of supinator motor branches to the posterior interosseous nerve in C7-T1 brachial plexus palsy.

    PubMed

    Bertelli, Jayme Augusto; Ghizoni, Marcos Flavio

    2010-07-01

    In C7-T1 palsies of the brachial plexus, shoulder and elbow function are preserved, but finger motion is absent. Finger flexion has been reconstructed by tendon or nerve transfers. Finger extension has been restored ineffectively by attaching the extensor tendons to the distal aspect of the dorsal radius (termed tenodesis) or by tendon transfers. In these palsies, supinator muscle function is preserved, because innervation stems from the C-6 root. The feasibility of transferring supinator branches to the posterior interosseous nerve has been documented in a previous anatomical study. In this paper, the authors report the clinical results of supinator motor nerve transfer to the posterior interosseous nerve in 4 patients with a C7-T1 root lesion. Four adult patients with C7-T1 root lesions underwent surgery between 5 and 7 months postinjury. The patients had preserved motion of the shoulder, elbow, and wrist, but they had complete palsy of finger motion. They underwent finger flexion reconstruction via transfer of the brachialis muscle, and finger and thumb extension were restored by transferring the supinator motor branches to the posterior interosseous nerve. This nerve transfer was performed through an incision over the proximal third of the radius. Dissection was carried out between the extensor carpi radialis brevis and the extensor digitorum communis. The patients were followed up as per regular protocol and underwent a final evaluation 12 months after surgery. To document the extent of recovery, the authors assessed the degree of active metacarpophalangeal joint extension of the long fingers. The thumb span was evaluated by measuring the distance between the thumb pulp and the lateral aspect of the index finger. Surgery to transfer the supinator motor branches to the posterior interosseous nerve was straightforward. Twelve months after surgery, all patients were capable of opening their hand and could fully extend their metacarpophalangeal joints. The distance of thumb abduction improved from 0 to 5 cm from the lateral aspect of the index finger. Transferring supinator motor nerves directly to the posterior interosseous nerve is effective in at least partially restoring thumb and finger extension in patients with lower-type injuries of the brachial plexus.

  12. Effects of spaceflight on rhesus quadrupedal locomotion after return to 1G

    NASA Technical Reports Server (NTRS)

    Recktenwald, M. R.; Hodgson, J. A.; Roy, R. R.; Riazanski, S.; McCall, G. E.; Kozlovskaya, I.; Washburn, D. A.; Fanton, J. W.; Edgerton, V. R.; Rumbaugh, D. M. (Principal Investigator)

    1999-01-01

    Effects of spaceflight on Rhesus quadrupedal locomotion after return to 1G. Locomotor performance, activation patterns of the soleus (Sol), medial gastrocnemius (MG), vastus lateralis (VL), and tibialis anterior (TA) and MG tendon force during quadrupedal stepping were studied in adult Rhesus before and after 14 days of either spaceflight (n = 2) or flight simulation at 1G (n = 3). Flight simulation involved duplication of the spaceflight conditions and experimental protocol in a 1G environment. Postflight, but not postsimulation, electromyographic (EMG) recordings revealed clonus-like activity in all muscles. Compared with preflight, the cycle period and burst durations of the primary extensors (Sol, MG, and VL) tended to decrease postflight. These decreases were associated with shorter steps. The flexor (TA) EMG burst duration postflight was similar to preflight, whereas the burst amplitude was elevated. Consequently, the Sol:TA and MG:TA EMG amplitude ratios were lower following flight, reflecting a "flexor bias." Together, these alterations in mean EMG amplitudes reflect differential adaptations in motor-unit recruitment patterns of flexors and extensors as well as fast and slow motor pools. Shorter cycle period and burst durations persisted throughout the 20-day postflight testing period, whereas mean EMG returned to preflight levels by 17 days postflight. Compared with presimulation, the simulation group showed slight increases in the cycle period and burst durations of all muscles. Mean EMG amplitude decreased in the Sol, increased in the MG and VL, and was unchanged in the TA. Thus adaptations observed postsimulation were different from those observed postflight, indicating that there was a response unique to the microgravity environment, i.e., the modulations in the nervous system controlling locomotion cannot merely be attributed to restriction of movement but appear to be the result of changes in the interpretation of load-related proprioceptive feedback to the nervous system. Peak MG tendon force amplitudes were approximately two times greater post- compared with preflight or presimulation. Adaptations in tendon force and EMG amplitude ratios indicate that the nervous system undergoes a reorganization of the recruitment patterns biased toward an increased recruitment of fast versus slow motor units and flexor versus extensor muscles. Combined, these data indicate that some details of the control of motor pools during locomotion are dependent on the persistence of Earth's gravitational environment.

  13. [PART-KESSLER TECHNIQUE WITH SUTURE ANCHOR IN REPAIR OF SPONTANEOUS Achilles TENDON RUPTURE].

    PubMed

    Qi, Jie; Duan, Liang; Li, Weiwei; Wei, Wenbo

    2016-02-01

    To summarize the application and experience of repairing spontaneous Achilles tendon rupture by part-Kessler technique with suture anchor. Between January 2011 and December 2013, 31 patients with spontaneous Achilles tendon rupture were treated by part-Kessler technique with suture anchor. Of 31 cases, 23 were male and 8 were female, aged 16-53 years (mean, 38 years). The left side was involved in 15 cases and the right side in 16 cases. The causes of injury included sudden heel pain and walking weakness during sports in 22 cases; no surefooted down-stairs, slip, and carrying heavy loads in 9 cases. The distance from broken site to the calcaneus adhension of Achilles tendon was 3-6 cm (mean, 4.2 cm). The time from injury to operation was 7 hours to 4 days (mean, 36.8 hours). All incisions healed by first intention without nerve injury or adhering with skin. The patients were followed up 6-24 months (mean, 15 months). All patients could complete 25 times heel raising without difficulty at 6 months after operation. No Achilles tendon rupture occurred again during follow-up. At 6 months after operation, the range of motion of the ankle joint in dorsiflexion and plantar flexion showed no significant difference between normal and affected sides (t=0.648, P=0.525; t=0.524, P=0.605). The circumference of the affected leg was significantly smaller than that of normal leg at 6 months after operation (t=2.074, P=0.041), but no significant difference was found between affected and normal sides at 12 months after operation (t=0.905, P=0.426). The American Orthopedic Foot and Ankle Society (AOFAS) scores at 6, 12, 18, and 24 months after operation were significantly higher than preoperative score (P<0.05); the score at 6 months after operation was significantly lower than that at other time points (P<0.05), but no significant difference was shown between the other time points (P>0.05). Repairing spontaneous Achilles tendon rupture by part-Kessler technique with suture anchor can supply strong strain and decrease the shear forces of suture. So part-Kessler technique with suture anchor is successful in repairing spontaneous Achilles tendon rupture.

  14. Photochemical tissue bonding

    DOEpatents

    Redmond, Robert W [Brookline, MA; Kochevar, Irene E [Charlestown, MA

    2012-01-10

    Photochemical tissue bonding methods include the application of a photosensitizer to a tissue and/or tissue graft, followed by irradiation with electromagnetic energy to produce a tissue seal. The methods are useful for tissue adhesion, such as in wound closure, tissue grafting, skin grafting, musculoskeletal tissue repair, ligament or tendon repair and corneal repair.

  15. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment.

    PubMed

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-02-01

    As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Case series; Level of evidence, 4. Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures.

  16. [Tendinosis and ruptures of the Achilles tendon].

    PubMed

    Amlang, M H; Zwipp, H

    2012-02-01

    Tendinosis of the Achilles tendon is a degenerative-reparative structural change of the tendon with microdefects, increases in cross-section due to cicatricial tendon regeneration, neoangiogenesis and reduction of elasticity. The previously used term tendinitis is only rarely used for the chronic form since signs of inflammation such as redness and hyperthermia or elevated levels of inflammatory parameters on laboratory testing are generally absent. Duplex sonography with visualization of the neovascularization has become a valuable supplement not only for diagnostics but also for therapy planning. The classic, conservative therapy for painful tendinosis consists of oral anti-inflammatory drugs, pain-adapted load reduction, raising the heel, stretching the calf musculature, and various physiotherapeutic interventions. When conservative treatment over a period of 4 - 6 months fails to produce any or non-adequate pain relief, an indication for surgical treatment should be considered. In the therapy for fresh ruptures of the Achilles tendon further developments in minimally invasive techniques have led to a worldwide paradigm change over the past 10 years. The decisive advantage of minimally invasive surgical techniques is the lower risk of wound infection as compared to the sutures of the open technique. When compared with conservative functional therapy the minimally invasive repair has the advantage of being less dependent on the compliance of the patient since, in the early phase of tendon healing the suture prevents a separation of the tendon ends upon controlled movements. However, not every patient with a ruptured Achilles tendon should be treated with a minimally invasive repair. Open tendon reconstruction and functional conservative therapy are still justified when the correct indication is given. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Aquarium Portal Technique for PASTA Lesion Repair.

    PubMed

    Meyer, Dominik C; Gerber, Christian; Familiari, Filippo

    2017-10-01

    The simultaneous arthroscopic exposure of the subacromial and intra-articular space of the shoulder is challenging in the presence of only partial-thickness rotator cuff tears. We present our experience and method of entering the joint through the opened rotator cuff interval from an anterosuperior portal between the coracoid process and anterior acromion. With moderate (approximately 30°) abduction and external rotation, the rotator interval opens readily, offering a view with the camera toward the anterior edge of the supraspinatus tendon. An anterior view on the anterior leading edge of the supraspinatus tendon is obtained, showing the subacromial space above and the glenohumeral space below the tendon, similar to the view in an aquarium. The rotator cuff can be elevated using a rod inserted intra-articularly from posterior, whereas anchors and other instruments may be inserted from lateral. This approach offers the advantages of full exposure of the posterior undersurface of the rotator cuff insertion; a convenient approximately 90° angle between the camera and instruments; and no need to change portals for anchor placement, tendon stitching, or suture handling. The objective of this Technical Note is to describe our arthroscopic repair approach (aquarium technique) to PASTA (partial articular supraspinatus tendon avulsion) lesions.

  18. Efficacy of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for the quantitative evaluation of the structural integrity of superficial digital flexor tendons in horses.

    PubMed

    van Schie, H T; Bakker, E M; Jonker, A M; van Weeren, P R

    2001-07-01

    To evaluate effectiveness of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for quantitative evaluation of tendon structural integrity in horses. 4 superficial digital flexor tendons (2 damaged tendons, 2 normal tendons). Transverse ultrasonographic images that precisely matched histologic sections were obtained in fixed steps along the long axis of each tendon. Distribution, intensity, and delineation of structure-related echoes, quantitatively expressed as the correlation ratio and steadiness ratio , were compared with histologic findings in tissue that was normal or had necrosis, early granulation, late granulation, early fibrosis, or inferior repair. In normal tendon, the even distribution of structure-related echoes with high intensity and sharp delineation yielded high correlation ratio and steadiness ratio. In areas of necrosis, collapsed endotendon septa yielded solid but blurred structure-related echoes (high correlation ration and low steadiness ratio). In early granulation tissue, complete lack of organization caused zero values for both ratios. In late granulation tissue, reorganization and swollen endotendon septa yielded poorly delineated structure-related echoes (high correlation ratio, low steadiness ratio). In early fibrosis, rearrangement of bundles resulted in normal correlation ration and slightly low steadiness ratio. In inferior repair, the almost complete lack of structural reorganization resulted in heterogeneous poorly delineated low-intensity echoes (low correlation ratio and steadiness ratio). The combination of correlation ratio and steadiness ratio accurately reflects histopathologic findings, making computerized correlation of ultrasonographic images an efficient tool for quantitative evaluation of tendon structural integrity.

  19. Simultaneous bilateral distal biceps tendon ruptures repaired using an endobutton technique: a case report

    PubMed Central

    2013-01-01

    Introduction The simultaneous rupture of both distal biceps tendons is a rare clinical entity that is difficult to treat and can have poor outcomes. A variety of treatment and rehabilitation options exist and have been reported for single sided and staged bilateral repairs, but none have described an approach for acute bilateral ruptures. Repairing distal biceps tendon ruptures using a single anterior incision and a cortical suspensory button technique has become increasingly popular in recent years. We present a report of our surgical approach using an endobutton technique and rehabilitation algorithm for this unusual injury pattern. Case presentation A 43-year-old Caucasian man presented with acute onset bilateral elbow pain while lifting a large sheet of drywall off the ground. He initially felt a ‘pop’ on the right and almost immediately felt another on the left after having to quickly shift the weight. He was unable to continue working and sought medical attention. His pain was predominantly in his bilateral antecubital fossae and he had significant swelling and ecchymoses. His clinical examination demonstrated no palpable tendon, a retracted biceps muscle belly, and clear supination weakness. Magnetic resonance imaging was performed and showed bilateral distal biceps tendon ruptures with retraction on both sides. After discussion with our patient, we decided that both sides would be repaired using a single anterior incision with endobutton fixation, first his right followed by his left six weeks later. Conclusion Overall, our patient did very well and had returned to full manual work by our last follow-up at 30 months. Although he was never able to return to competitive recreational hockey and was left with mild lateral antebrachial cutaneous nerve dysesthesias on his right, he felt he was at 85% of his premorbid level of function. We describe what we believe to be, to the best of our knowledge, the first case of simultaneous bilateral distal biceps tendon ruptures successfully treated with a single-incision endobutton technique, which represents a valid option in managing this difficult problem. PMID:23972255

  20. Customizing Extensor Reconstruction in Vascularized Toe Joint Transfers to Finger Proximal Interphalangeal Joints: A Strategic Approach for Correcting Extensor Lag.

    PubMed

    Loh, Charles Yuen Yung; Hsu, Chung-Chen; Lin, Cheng-Hung; Chen, Shih-Heng; Lien, Shwu-Huei; Lin, Chih-Hung; Wei, Fu-Chan; Lin, Yu-Te

    2017-04-01

    Vascularized toe proximal interphalangeal joint transfer allows the restoration of damaged joints. However, extensor lag and poor arc of motion have been reported. The authors present their outcomes of treatment according to a novel reconstructive algorithm that addresses extensor lag and allows for consistent results postoperatively. Vascularized toe joint transfers were performed in a consecutive series of 26 digits in 25 patients. The average age was 30.5 years, with 14 right and 12 left hands. Reconstructed digits included eight index, 10 middle, and eight ring fingers. Simultaneous extensor reconstructions were performed and eight were centralization of lateral bands, five were direct extensor digitorum longus-to-extensor digitorum communis repairs, and 13 were central slip reconstructions. The average length of follow-up was 16.7 months. The average extension lag was 17.9 degrees. The arc of motion was 57.7 degrees (81.7 percent functional use of pretransfer toe proximal interphalangeal joint arc of motion). There was no significant difference in the reconstructed proximal interphalangeal joint arc of motion for the handedness (p = 0.23), recipient digits (p = 0.37), or surgical experience in vascularized toe joint transfer (p = 0.25). The outcomes of different techniques of extensor mechanism reconstruction were similar in terms of extensor lag, arc of motion, and reconstructed finger arc of motion compared with the pretransfer toe proximal interphalangeal joint arc of motion. With this treatment algorithm, consistent outcomes can be produced with minimal extensor lag and maximum use of potential toe proximal interphalangeal joint arc of motion. Therapeutic, IV.

  1. Saw injuries causing phalangeal neck fractures in adults.

    PubMed

    Al-Qattan, Mohammad M

    2012-07-01

    The outcome of adult phalangeal neck fractures caused by saws has not been previously investigated. Over a 15-year period, a total of 36 cases of saw-related injuries resulting in phalangeal neck fractures of the middle phalanx of the finger or the proximal phalanx of the thumb were treated. All injuries were industrial and covered by insurance. They were all adult males with type II fractures. The fracture were managed by K-wire fixation, immobilizing the distal joint only. The proximal joints were mobilized immediately after surgery and the K-wire was removed after 5 weeks. The following 2 patterns of saw injuries were observed: dorsal impact injuries resulting in a phalangeal neck fracture and concurrent extensor tendon injury (group I, n = 20 patients), and dorsolateral impact injuries resulting in concurrent extensor (± partial flexor) tendon and nerve injury (group II, n = 16 patients). The outcome with respect to range of motion and return to work was significantly better in the former group. Major complications such as nonunion, malunion, avascular necrosis of the phalangeal head, osteomyelitis, or contractures of the proximal interphalangeal joints were not observed. Two patients (1 in each group) had superficial pin-site infection. It was concluded that adult phalangeal neck fractures caused by saws is a separate entity from the previously reported series of closed phalangeal neck fractures in adults.

  2. The First Experience of Triple Nerve Transfer in Proximal Radial Nerve Palsy.

    PubMed

    Emamhadi, Mohammadreza; Andalib, Sasan

    2018-01-01

    Injury to distal portion of posterior cord of brachial plexus leads to palsy of radial and axillary nerves. Symptoms are usually motor deficits of the deltoid muscle; triceps brachii muscle; and extensor muscles of the wrist, thumb, and fingers. Tendon transfers, nerve grafts, and nerve transfers are options for surgical treatment of proximal radial nerve palsy to restore some motor functions. Tendon transfer is painful, requires a long immobilization, and decreases donor muscle strength; nevertheless, nerve transfer produces promising outcomes. We present a patient with proximal radial nerve palsy following a blunt injury undergoing triple nerve transfer. The patient was involved in a motorcycle accident with complete palsy of the radial and axillary nerves. After 6 months, on admission, he showed spontaneous recovery of axillary nerve palsy, but radial nerve palsy remained. We performed triple nerve transfer, fascicle of ulnar nerve to long head of the triceps branch of radial nerve, flexor digitorum superficialis branch of median nerve to extensor carpi radialis brevis branch of radial nerve, and flexor carpi radialis branch of median nerve to posterior interosseous nerve, for restoration of elbow, wrist, and finger extensions, respectively. Our experience confirmed functional elbow, wrist, and finger extensions in the patient. Triple nerve transfer restores functions of the upper limb in patients with debilitating radial nerve palsy after blunt injuries. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Novel Augmentation Technique for Patellar Tendon Repair Improves Strength and Decreases Gap Formation: A Cadaveric Study.

    PubMed

    Black, James C; Ricci, William M; Gardner, Michael J; McAndrew, Christopher M; Agarwalla, Avinesh; Wojahn, Robert D; Abar, Orchid; Tang, Simon Y

    2016-12-01

    Patellar tendon ruptures commonly are repaired using transosseous patellar drill tunnels with modified-Krackow sutures in the patellar tendon. This simple suture technique has been associated with failure rates and poor clinical outcomes in a modest proportion of patients. Failure of this repair technique can result from gap formation during loading or a single catastrophic event. Several augmentation techniques have been described to improve the integrity of the repair, but standardized biomechanical evaluation of repair strength among different techniques is lacking. The purpose of this study was to describe a novel figure-of-eight suture technique to augment traditional fixation and evaluate its biomechanical performance. We hypothesized that the augmentation technique would (1) reduce gap formation during cyclic loading and (2) increase the maximum load to failure. Ten pairs (two male, eight female) of fresh-frozen cadaveric knees free of overt disorders or patellar tendon damage were used (average donor age, 76 years; range, 65-87 years). For each pair, one specimen underwent the standard transosseous tunnel suture repair with a modified-Krackow suture technique and the second underwent the standard repair with our experimental augmentation method. Nine pairs were suitable for testing. Each specimen underwent cyclic loading while continuously measuring gap formation across the repair. At the completion of cyclic loading, load to failure testing was performed. A difference in gap formation and mean load to failure was seen in favor of the augmentation technique. At 250 cycles, a 68% increase in gap formation was seen for the control group (control: 5.96 ± 0.86 mm [95% CI, 5.30-6.62 mm]; augmentation: 3.55 ± 0.56 mm [95% CI, 3.12-3.98 mm]; p = 0.02). The mean load to failure was 13% greater in the augmentation group (control: 899.57 ± 96.94 N [95% CI, 825.06-974.09 N]; augmentation: 1030.70 ± 122.41 N [95% CI, 936.61-1124.79 N]; p = 0.01). This biomechanical study showed improved performance of a novel augmentation technique compared with the standard repair, in terms of reduced gap formation during cyclic loading and increased maximum load to failure. Decreased gap formation and higher load to failure may improve healing potential and minimize failure risk. This study shows a potential biomechanical advantage of the augmentation technique, providing support for future clinical investigations comparing this technique with other repair methods that are in common use such as transosseous suture repair.

  4. Simultaneous acute rotator cuff tear and distal biceps rupture in a strongman competitor.

    PubMed

    George, Michael S

    2010-04-01

    Acute rotator cuff tear is commonly associated with tearing of the proximal biceps tendon, but has never been reported to occur simultaneously with a distal biceps tendon rupture. A 38-year-old right-hand-dominant strongman competitor attempted a 300-pound overhead axle press and experienced immediate pain in the right shoulder and elbow. He had no known systemic risk factors for tendon ruptures including hyperparathyroidism, hemodialysis, alcoholism, rheumatoid arthritis, statin medications, fluoroquinolones, and steroid use.Right shoulder magnetic resonance imaging (MRI) showed a full-thickness supraspinatus tear with 3 cm of retraction. There was minimal fatty infiltration of the supraspinatus on the sagittal cuts consistent with acute rupture. The subscapularis was intact. The long head of the biceps tendon had mild medial subluxation but was completely within the bicipital groove. Right elbow MRI showed a complete distal biceps tendon rupture. Thirteen days after his injury, the patient underwent arthroscopic supraspinatus repair and proximal biceps tenodesis. Distal biceps tendon repair was performed using the modified 2-incision muscle-splitting technique. At 24-month follow-up, the patient was pain free and had returned to full activity including weightlifting but had not returned to strongman competition.This is the first report of simultaneous acute full thickness ruptures of the rotator cuff and distal biceps tendon. This case report underscores the importance of a complete physical examination and a high index of suspicion for additional concomitant injuries, particularly in athletes with unusually high stresses to the body. Copyright 2010, SLACK Incorporated.

  5. [Patella fractures in knee arthroplasty].

    PubMed

    Roth, A; Ghanem, M; Fakler, J

    2016-05-01

    Periprosthetic patella fractures occur both with and without retropatellar joint replacement. A non-operative treatment yields satisfactory results with low morbidity. It can be applied in minimally displaced fractures that have an intact retropatellar component and an intact extensor mechanism, combined with an initial immobilization. The surgical treatment is associated with relatively poor results and with high complication rates. There was only minor improvement of functional results, no matter which surgical technique was used. Surgical intervention is still required in fractures with a loosening of the patellar component, considerable dislocations of fragments, and damage to or rupture of the extensor mechanism. In particular, type II fractures require repair of the extensor mechanism and the fracture or patellectomy. Type III fractures require a revision or resection of the patella, a patelloplasty or total patellectomy. In addition, early or late reconstruction using allograft to restore the extensor mechanism can be taken in consideration.

  6. The effect of corticosteroid versus platelet-rich plasma injection therapies for the management of lateral epicondylitis: A systematic review

    PubMed Central

    Ben-Nafa, Walid; Munro, Wendy

    2018-01-01

    Introduction: Lateral epicondylitis is a common musculoskeletal disorder of the upper limb. Corticosteroid injection has been widely used as a major mode of treatment. However, better understanding of the pathophysiology of the disease led to a major change in treating the disease, with new options including platelet-rich plasma (PRP) are currently used. Objectives/research aim: To systematically evaluate the effect of corticosteroid versus PRP injections for the treatment of LE. Hypothesis: PRP injections provide longer-term therapeutic effect and less rate of complications compared to corticosteroid injection. Level of evidence: Level 2 evidence (4 included studies are of level 1 evidence, 1 study of level 2 evidence). Design: Systematic Review (according to PRISMA guidelines). Methods: Eleven databases used to search for relevant primary studies comparing the effects of corticosteroid and PRP injections for the treatment of LE. Quality appraisal of studies performed using Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0, CASP Randomised Controlled Trial Checklist, and SIGN Methodology Checklist 2. Results: 732 papers were identified. Five randomised controlled trials (250 Patients) met the inclusion criteria. Clinical findings: Corticosteroid injections provided rapid symptomatic improvement with maximum effect at 6/8/8 weeks before symptoms recurrence, whereas PRP showed slower ongoing improvements up to 24/52/104 weeks(3 studies). Corticosteroid showed more rapid symptomatic improvement of symptoms compared to PRP up to the study end-point of 3 months(1 study). Comparable therapeutic effects of corticosteroid and PRP were observed at 6 weeks(1 study). Ultrasonographic Findings: (1) Doppler activity decreased more significantly in patients who received corticosteroid compared to PRP. (2) Reduced tendon thickness and more patients with cortical erosion noted in corticosteroid group whereas increased tendon thickness and less number of patients with common extensor tendon tears noted in PRP group. (3) Fewer patients reported Probe-induced tenderness and oedema in the common extensor tendon in both corticosteroid and PRP groups (2 studies). Conclusion: Corticosteroid injections provide rapid therapeutic effect in the short-term with recurrence of symptoms afterwards, compared to the relatively slower but longer-term effect of platelet-rich plasma. PMID:29561260

  7. Performance outcomes after repair of complete achilles tendon ruptures in national basketball association players.

    PubMed

    Amin, Nirav H; Old, Andrew B; Tabb, Loni P; Garg, Rohit; Toossi, Nader; Cerynik, Douglas L

    2013-08-01

    A complete rupture of the Achilles tendon is a devastating injury. Variables affecting return to competition and performance changes for National Basketball Association (NBA) players are not readily evident. Players in the NBA who ruptured their Achilles tendons and who underwent surgical repair would have more experience in the league, and the performance of those who were able to return to competition would be decreased when compared with their performance before injury and with their control-matched peers. Cohort study; Level of evidence, 3. Data for 18 basketball players with Achilles tendon repair over a 23-year period (1988-2011) were obtained from injury reports, press releases, and player profiles. Variables included age, body mass index (BMI), player position, and number of years playing in the league. Individual season statistics were obtained, and the NBA player efficiency rating (PER) was calculated for 2 seasons before and after injury. Controls were matched by playing position, number of seasons played, and performance statistics. Univariate and multivariate analyses were performed to assess the effect of each factor. At the time of injury, the average age was 29.7 years, average BMI was 25.6, and average playing experience was 7.6 years. Seven players never returned to play an NBA game, whereas 11 players returned to play 1 season, with 8 of those players returning for ≥2 seasons. Players who returned missed an average of 55.9 games. The PER was reduced by 4.57 (P = .003) in the first season and by 4.38 (P = .010) in the second season. When compared with controls, players demonstrated a significant decline in the PER the first season (P = .038) and second season (P = .081) after their return. The NBA players who returned to play after repair of complete Achilles tendon ruptures showed a significant decrease in playing time and performance. Thirty-nine percent of players never returned to play.

  8. REHABILITATION OF A SURGICALLY REPAIRED RUPTURE OF THE DISTAL BICEPS TENDON IN AN ACTIVE MIDDLE AGED MALE: A CASE REPORT

    PubMed Central

    Sayers, Stephen P.; LaFontaine, Tom; Scheussler, Scott

    2012-01-01

    Background: Complete rupture of the distal tendon of the biceps brachii is relatively rare and there is little information to guide therapists in rehabilitation after this injury. The purposes of this case report are to review the rehabilitation concepts used for treating such an injury, and discuss how to modify exercises during rehabilitation based on patient progression while adhering to physician recommended guidelines and standard treatment protocols. Case Presentation: The patient was an active 38‐year old male experienced in weight‐training. He presented with a surgically repaired right distal biceps tendon following an accident on a trampoline adapted with a bungee suspension harness. The intervention focused on restoring range of motion and strengthening of the supporting muscles of the upper extremity without placing undue stress on the biceps brachii. Outcomes: The patient was able to progress from a moderate restriction in ROM to full AROM two weeks ahead of the physician's post‐operative orders and initiate a re‐strengthening protocol by the eighth week of rehabilitation. At the eighth post‐operative week the patient reported no deficits in functional abilities throughout his normal daily activities with his affected upper extremity. Discussion: The results of this case report strengthen current knowledge regarding physical therapy treatment for a distal biceps tendon repair while at the same time providing new insights for future protocol considerations in active individuals. Most current protocols do not advocate aggressive stretching, AROM, or strengthening of a surgically repaired biceps tendon early in the rehabilitation process due to the fear of a re‐rupture. In the opinion of the authors, if full AROM can be achieved before the 6th week of rehabilitation, initiating a slow transition into light strengthening of the biceps brachii may be possible. Level of evidence: 4‐Single Case report PMID:23316429

  9. Simultaneous Bilateral Quadriceps Tendon Rupture in Patient with Chronic Renal Failure

    PubMed Central

    Lee, Yunseok; Kim, Byounggook; Chung, Ju-Hwan

    2011-01-01

    Simultaneous bilateral spontaneous rupture of the quadriceps tendon is a very rare condition and only a few cases have been reported in the literature. The etiology is not clear yet. But it occurs infrequently in patients with chronic metabolic disorders. A 30-year-old female patient with simultaneous bilateral spontaneous quadriceps tendon rupture visited our hospital. She had chronic renal failure and her parathyroid hormone level was elevated due to parathyroid adenoma. We report a surgical repair of both quadriceps tendons of a patient with chronic renal failure as well as management of hyperparathyroidism. PMID:22570843

  10. Genipin crosslinker releasing sutures for improving the mechanical/repair strength of damaged connective tissue.

    PubMed

    Sundararaj, Sharath; Slusarewicz, Paul; Brown, Matt; Hedman, Thomas

    2017-11-01

    The most common mode of surgical repair of ruptured tendons and ligaments involves the use of sutures for reattachment. However, there is a high incidence of rerupture and repair failure due to pulling out of the suture material from the damaged connective tissue. The main goal of this research was to achieve a localized delivery of crosslinking agent genipin (GP) from rapid-release biodegradable coatings on sutures, for strengthening the repair of ruptured connective tissue. Our hypothesis is that GP released from the suture coating will lead to exogenous crosslinking of native connective tissue resulting in beneficial effects on clinically relevant mechanical parameters such as tear resistance, tissue strength, and energy required to rupture the tissue (toughness). Sutures were successfully coated with a biodegradable polymer layer loaded with the crosslinking agent genipin, without compromising the mechanical properties of the suture. The rapid-release of genipin was achieved under both in vitro and ex vivo conditions. Exogenous crosslinking using these genipin releasing sutures was demonstrated using equine tendons. The tendons treated with genipin releasing sutures showed significant improvement in failure load, energy required for pull-out failure, and stiffness. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2199-2205, 2017. © 2016 Wiley Periodicals, Inc.

  11. Phenytoin accelerates tendon healing in a rat model of Achilles tendon rupture.

    PubMed

    Hajipour, B; Navali, A M; Mohammad, S Ali; Mousavi, G; Akbari, M Gahvechi; Miyandoab, T Maleki; Roshangar, L; Saleh, B Mohammadi; Kermani, T Asvadi; Laleh, F Moutab; Ghabili, M

    2016-01-01

    Tendons are vulnerable to various types of acute or chronic injures. Different methods have been investigated to achieve better healing. Phenytoin is a drug which could stimulate fibroblasts to produce collagen. This experimental study was performed to assess the effect of phenytoin on tendon healing in a rat model of tendon rupture. Thirty healthy rats were divided into 3 groups, 1) Sham group; 2) Tendon rupture; 3) Tendon rupture+phenytoin (100 mg/kg intraperitoneally) for 21 days. On 21st day after tendon injury, the rats were anesthetized and tendon tissue was sampled for studying by light and electron microscopy. Qualitative and quantitative microscopic comparisons of the repair tissues of both groups were made on the 21st day. The results obtained from light and electron microscopy studies showed that tendon tissue healing was significantly better in phenytoin group compared to the control group (p < 0.05). Systemic administration of phenytoin may have a positive effect on tendon healing by increasing fibroblast quantity, fibrillar collagen synthesis, vascularity, and suppressing inflammation (Tab. 2, Ref. 25).

  12. Tendinous tissue properties after short- and long-term functional overload: Differences between controls, 12 weeks and 4 years of resistance training.

    PubMed

    Massey, G J; Balshaw, T G; Maden-Wilkinson, T M; Folland, J P

    2018-04-01

    The potential for tendinous tissues to adapt to functional overload, especially after several years of exposure to heavy-resistance training, is largely unexplored. This study compared the morphological and mechanical characteristics of the patellar tendon and knee extensor tendon-aponeurosis complex between young men exposed to long-term (4 years; n = 16), short-term (12 weeks; n = 15) and no (untrained controls; n = 39) functional overload in the form of heavy-resistance training. Patellar tendon cross-sectional area, vastus lateralis aponeurosis area and quadriceps femoris volume, plus patellar tendon stiffness and Young's modulus, and tendon-aponeurosis complex stiffness, were quantified with MRI, dynamometry and ultrasonography. As expected, long-term trained had greater muscle strength and volume (+58% and +56% vs untrained, both P < .001), as well as a greater aponeurosis area (+17% vs untrained, P < .01), but tendon cross-sectional area (mean and regional) was not different between groups. Only long-term trained had reduced patellar tendon elongation/strain over the whole force/stress range, whilst both short-term and long-term overload groups had similarly greater stiffness/Young's modulus at high force/stress (short-term +25/22%, and long-term +17/23% vs untrained; all P < .05). Tendon-aponeurosis complex stiffness was not different between groups (ANOVA, P = .149). Despite large differences in muscle strength and size, years of resistance training did not induce tendon hypertrophy. Both short-term and long-term overload demonstrated similar increases in high-force mechanical and material stiffness, but reduced elongation/strain over the whole force/stress range occurred only after years of overload, indicating a force/strain specific time-course to these adaptations. © 2017 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  13. Simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft.

    PubMed

    Shin, Sang-Jin; Campbell, Sean; Scott, Jonathan; McGarry, Michelle H; Lee, Thay Q

    2014-09-01

    The purpose of this study was to introduce a novel surgical technique for simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft and to compare its biomechanical characteristics to those of a coracoid cerclage reconstruction of the coracoclavicular ligaments. Six matched pairs of human acromioclavicular joints with an average age of 54.8 ± 7.8 years were used. One shoulder from each pair received the single tendon acromioclavicular-coracoclavicular reconstruction; the contralateral shoulder received the coracoid cerclage reconstruction. Bovine extensor tendon was used for both techniques. The single tendon acromioclavicular-coracoclavicular reconstruction technique provided anatomic restoration of the two coracoclavicular ligaments and the superior and inferior acromioclavicular ligaments simultaneously using one coracoid hole, one acromion hole, and two clavicular holes with interference screws. Anterior-posterior and superior-inferior translations were quantified for all specimens before and after reconstruction, followed by load to failure testing. Following coracoid cerclage reconstruction, total anterior-posterior translation was significantly greater than intact (10.0 ± 5.7 mm; p = 0.008). Following single tendon acromioclavicular-coracoclavicular reconstruction, there was no significant difference in anterior-posterior translation compared to intact (-1.6 ± 2.2 mm; n.s.). The coracoid cerclage technique demonstrated significantly greater anterior-posterior translation than the single tendon acromioclavicular-coracoclavicular technique (p = 0.007). Both techniques restored superior-inferior translation to the intact condition (n.s.). Ultimate load, deformation at ultimate load, and energy absorbed at ultimate load were significantly greater after acromioclavicular-coracoclavicular reconstruction than after coracoid cerclage reconstruction (p < 0.05). This novel single tendon anatomic acromioclavicular-coracoclavicular reconstruction provided greater stability and stronger load to failure characteristics than the isolated coracoid cerclage reconstruction. A simultaneous acromioclavicular-coracoclavicular reconstruction technique using a single free tendon graft provided anatomic reconstruction of the conoid, trapezoid, and superior and inferior acromioclavicular ligaments and may reduce postoperative subluxation.

  14. Cadaver study of anatomic landmark identification for placing ankle arthroscopy portals.

    PubMed

    Scheibling, B; Koch, G; Clavert, P

    2017-05-01

    Arthroscopy-assisted surgery is now widely used at the ankle for osteochondral lesions of the talus, anterior and posterior impingement syndromes, talocrural or subtalar fusion, foreign body removal, and ankle instability. Injuries to the vessels and nerves may occur during these procedures. To determine whether ultrasound topographic identification of vulnerable structures decreased the risk of iatrogenic injuries to vessels, nerves, and tendons and influenced the distance separating vulnerable structures from the arthroscope introduced through four different portals. Ultrasonography to identify vulnerable structures before or during arthroscopic surgery on the ankle may be useful. Twenty fresh cadaver ankles from body donations to the anatomy institute in Strasbourg, France, were divided into two equal groups. Preoperative ultrasonography to mark the trajectories of vessels, nerves, and tendons was performed in one group but not in the other. The portals were created using a 4-mm trocar. Each portal was then dissected. The primary evaluation criterion was the presence or absence of injuries to vessels, nerves, and tendons. The secondary evaluation criterion was the distance between these structures and the arthroscope. No tendon injuries occurred with ultrasonography. Without ultrasonography, there were two full-thickness tendon lesions, one to the extensor hallucis longus and the other to the Achilles tendon. Furthermore, with the anterolateral, anteromedial, and posteromedial portals, the distance separating the vessels and nerves from the arthroscope was greater with than without ultrasonography (P=0.041, P=0.005, and P=0.002), respectively; no significant difference was found with the anterior portal. Preoperative ultrasound topographic identification decreases the risk of iatrogenic injury to the vessels, nerves, and tendons during ankle arthroscopy and places these structures at a safer distance from the arthroscope. Our hypothesis was confirmed. IV, cadaver study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. No prosthetic management of massive and irreparable rotator cuff tears

    PubMed Central

    Garofalo, Raffaele; Cesari, Eugenio

    2014-01-01

    A massive rotator cuff tear is not necessarily irreparable. Number of tendons involved, muscle-tendon unit quality, and decreased acromionhumeral distance (AHD) are as important as tear size in determining reparability of lesion. Massive and irreparable rotator cuff tears cannot be anatomically repaired to the bone and are a common source of pain and disability even in middle-aged patients. In these patients when conservative management has failed, it is possible to perform different surgical techniques. A functional repair can help to restore the horizontal force couple of the cuff on the humeral head and to increase the AHD. Debridement of irreparable tears and biceps tenotomy or tenodesis can have a role in low functional demand patients but results deteriorate over time. Recently, several commercially available tissue-engineered biological and synthetic scaffolds have been developed to augment rotator cuff repairs. The aim is to provide a mechanical improvement in case of poor quality tissue at time zero and give a support to have a better cuff healing. In selected cases, the scaffold can be used also to bridge tendon defect. Patients who not have pseudoparalysis, cuff tear arthropathy and with intact deltoid function can benefit from tendon transfers with satisfactory outcomes. These different procedures should be chosen for each patient with selected criteria and after a satisfactory explanation about the really possible expectation after surgery. PMID:27582930

  16. Arthroscopic Medial Meniscus Posterior Root Reconstruction Using Auto-Gracilis Tendon.

    PubMed

    Lee, Dhong Won; Haque, Russel; Chung, Kyu Sung; Kim, Jin Goo

    2017-08-01

    There have been several techniques to repair the medial meniscus posterior root tears (MMPRTs) with the goal of restoring the anatomic and firm fixation of the meniscal root to bone. Many anatomic studies about the menisci also have been developed, so a better understanding of the anatomy could help surgeons perform correct fixation of the MMPRTs. The meniscal roots have ligament-like structures that firmly attach the menisci to the tibial plateau, and this structural concept is important to restore normal biomechanics after anatomic root repair. We present arthroscopic transtibial medial meniscus posterior root reconstruction using auto-gracilis tendon.

  17. Clinical Outcomes and Complications of Percutaneous Achilles Repair System Versus Open Technique for Acute Achilles Tendon Ruptures.

    PubMed

    Hsu, Andrew R; Jones, Carroll P; Cohen, Bruce E; Davis, W Hodges; Ellington, J Kent; Anderson, Robert B

    2015-11-01

    Limited incision techniques for acute Achilles tendon ruptures have been developed in recent years to improve recovery and reduce postoperative complications compared with traditional open repair. The purpose of this retrospective cohort study was to analyze the clinical outcomes and postoperative complications between acute Achilles tendon ruptures treated using a percutaneous Achilles repair system (PARS [Arthrex, Inc, Naples, FL]) versus open repair and evaluate the overall outcomes for operatively treated Achilles ruptures. Between 2005 and 2014, 270 consecutive cases of operatively treated acute Achilles tendon ruptures were reviewed (101 PARS, 169 open). Patients with Achilles tendinopathy, insertional ruptures, chronic tears, or less than 3-month follow-up were excluded. Operative treatment consisted of a percutaneous technique (PARS) using a 2-cm transverse incision with FiberWire (Arthrex, Inc, Naples, FL) sutures or open repair using a 5- to 8-cm posteromedial incision with FiberWire in a Krackow fashion reinforced with absorbable sutures. Patient demographics were recorded along with medical comorbidities, activity at injury, time from injury to surgery, length of follow-up, return to baseline activities by 5 months, and postoperative complications. The most common activity during injury for both groups was basketball (PARS: 39%, open: 47%). A greater number of patients treated with PARS were able to return to baseline physical activities by 5 months compared with the open group (PARS: 98%, open: 82%; P = .0001). There were no significant differences (P > .05) between groups in rates of rerupture (P = 1.0), sural neuritis (P = .16), wound dehiscence (P = .74), superficial (P = .29) and/or deep infection (P = .29), or reoperation (P = .13). There were no deep vein thromboses (DVTs) or reruptures in either group. In the PARS group, there were no cases of sural neuritis, 3 cases (3%) of superficial wound dehiscence, and 2 reoperations (2%) for superficial foreign-body reaction to FiberWire. In the open group, there were 5 cases (3%) of sural neuritis, 7 cases (4%) of superficial wound dehiscence, 3 cases (2%) of superficial infection, and 3 reoperations (2%) for deep infection. The present study reports the largest single-center series of acute Achilles tendon ruptures in the literature with lower complication rates for operatively treated Achilles ruptures compared with previous reports. The overall complication rate for all operatively treated Achilles ruptures was 8.5% with no reruptures, and most patients (88%) were able to return to baseline activities by 5 months after surgery. There were no significant differences in rates of postoperative complications between PARS and open repair for acute Achilles tendon ruptures. Level III, retrospective cohort study. © The Author(s) 2015.

  18. Anterolateral Ligament Reconstruction Protects the Repaired Medial Meniscus: A Comparative Study of 383 Anterior Cruciate Ligament Reconstructions From the SANTI Study Group With a Minimum Follow-up of 2 Years.

    PubMed

    Sonnery-Cottet, Bertrand; Saithna, Adnan; Blakeney, William G; Ouanezar, Herve; Borade, Amrut; Daggett, Matt; Thaunat, Mathieu; Fayard, Jean-Marie; Romain Delaloye, Jean

    2018-05-01

    The prevalence of osteoarthritis after successful meniscal repair is significantly less than that after failed meniscal repair. To determine whether the addition of anterolateral ligament reconstruction (ALLR) confers a protective effect on medial meniscal repair performed at the time of anterior cruciate ligament reconstruction (ACLR). Cohort study; Level of evidence, 3. Retrospective analysis of prospectively collected data was performed to include all patients who had undergone primary ACLR with concomitant posterior horn medial meniscal repair through a posteromedial portal between January 2013 and August 2015. ACLR autograft choice was bone-patellar tendon-bone, hamstring tendons (or quadrupled hamstring tendons), or quadrupled semitendinosus tendon graft with or without ALLR. At the end of the study period, all patients were contacted to determine if they had undergone reoperation. A Kaplan-Meier survival curve was plotted, and a Cox proportional hazards regression model was used to perform multivariate analysis. A total of 383 patients (mean ± SD age, 27.4 ± 9.2 years) were included with a mean follow-up of 37.4 months (range, 24-54.9 months): 194 patients underwent an isolated ACLR, and 189 underwent a combined ACLR + ALLR. At final follow-up, there was no significant difference between groups in postoperative side-to-side laxity (isolated ACLR group, 0.9 ± 0.9 mm [min to max, -1 to 3]; ACLR + ALLR group, 0.8 ± 1.0 mm [min to max, -2 to 3]; P = .2120) or Lysholm score (isolated ACLR group, 93.0 [95% CI, 91.3-94.7]; ACLR + ALLR group, 93.7 [95% CI, 92.3-95.1]; P = .556). Forty-three patients (11.2%) underwent reoperation for failure of the medial meniscal repair or a new tear. The survival rates of meniscal repair at 36 months were 91.2% (95% CI, 85.4%-94.8) in the ACLR + ALLR group and 83.8% (95% CI, 77.1%-88.7%; P = .033) in the ACLR group. The probability of failure of medial meniscal repair was >2 times lower in patients with ACLR + ALLR as compared with patients with isolated ACLR (hazard ratio, 0.443; 95% CI, 0.218-0.866). No other prognosticators of meniscal repair failure were identified. Combined ACLR and ALLR is associated with a significantly lower rate of failure of medial meniscal repairs when compared with those performed at the time of isolated ACLR.

  19. Can Grafts Provide Superior Tendon Healing and Clinical Outcomes After Rotator Cuff Repairs?

    PubMed Central

    Ono, Yohei; Dávalos Herrera, Diego Alejandro; Woodmass, Jarret M.; Boorman, Richard S.; Thornton, Gail M.; Lo, Ian K. Y.

    2016-01-01

    Background: Arthroscopic repair of large to massive rotator cuff tears commonly retear. To improve healing rates, a number of different approaches have been utilized, including the use of grafts, which may enhance the biomechanical and biologic aspects of the repair construct. However, the outcomes after the use of grafts are diverse. Purpose: To systematically review the literature for large to massive rotator cuff tears to determine whether the use of grafts generally provides superior tendon healing and clinical outcomes to the repairs without grafts. Study Design: Systematic review; Level of evidence, 3. Methods: A systematic review of the literature was performed. Clinical studies comparing the repairs with (graft group) and without grafts (control group) were included and analyzed. The primary outcome was tendon healing on either magnetic resonance imaging or ultrasound. The secondary outcome measures included visual analog scale for pain, University of California at Los Angles (UCLA) score, and forward elevation range. Differences between groups in all outcome measures were statistically analyzed. Results: Six comparative studies (level of evidence 2 or 3) with 13 study groups were included. A total of 242 repairs in the graft group (mean age, 62.5 ± 4.6 years) and 185 repairs in the control group (mean age, 62.5 ± 5.0 years) were analyzed. The graft types utilized included autograft (fascia lata) in 1 study, allograft (human dermis) in 2 studies, xenograft (bovine pericardium, porcine small intestine submucosa) in 2 studies, synthetic graft (polypropylene) in 1 study, and a combination of autograft (the long head of biceps) and synthetic graft (polypropylene) in 1 study. The overall mean follow-up time was 28.4 ± 9.0 months. When 1 or 2 studies/study groups were excluded due to practical or statistical reasons, the graft group demonstrated significantly improved healing (odds ratio, 2.48; 95% CI, 1.58-3.90; P < .0001) and all clinical outcome measures at final follow-up (P ≤ .02). Conclusion: The use of grafts generally provides superior tendon healing and clinical outcomes compared to repairs without grafts, except for some specific graft types (eg, porcine small intestine submucosa, bovine pericardium). Further investigations are required to determine the benefits of the use of grafts. PMID:28203585

  20. Differences in Pedaling Technique in Cycling: A Cluster Analysis.

    PubMed

    Lanferdini, Fábio J; Bini, Rodrigo R; Figueiredo, Pedro; Diefenthaeler, Fernando; Mota, Carlos B; Arndt, Anton; Vaz, Marco A

    2016-10-01

    To employ cluster analysis to assess if cyclists would opt for different strategies in terms of neuromuscular patterns when pedaling at the power output of their second ventilatory threshold (PO VT2 ) compared with cycling at their maximal power output (PO MAX ). Twenty athletes performed an incremental cycling test to determine their power output (PO MAX and PO VT2 ; first session), and pedal forces, muscle activation, muscle-tendon unit length, and vastus lateralis architecture (fascicle length, pennation angle, and muscle thickness) were recorded (second session) in PO MAX and PO VT2 . Athletes were assigned to 2 clusters based on the behavior of outcome variables at PO VT2 and PO MAX using cluster analysis. Clusters 1 (n = 14) and 2 (n = 6) showed similar power output and oxygen uptake. Cluster 1 presented larger increases in pedal force and knee power than cluster 2, without differences for the index of effectiveness. Cluster 1 presented less variation in knee angle, muscle-tendon unit length, pennation angle, and tendon length than cluster 2. However, clusters 1 and 2 showed similar muscle thickness, fascicle length, and muscle activation. When cycling at PO VT2 vs PO MAX , cyclists could opt for keeping a constant knee power and pedal-force production, associated with an increase in tendon excursion and a constant fascicle length. Increases in power output lead to greater variations in knee angle, muscle-tendon unit length, tendon length, and pennation angle of vastus lateralis for a similar knee-extensor activation and smaller pedal-force changes in cyclists from cluster 2 than in cluster 1.

  1. Extended healing validation of an artificial tendon to connect the quadriceps muscle to the Tibia: 180-day study.

    PubMed

    Melvin, Alan J; Litsky, Alan S; Mayerson, Joel L; Stringer, Keith; Juncosa-Melvin, Natalia

    2012-07-01

    Whenever a tendon or its bone insertion is disrupted or removed, existing surgical techniques provide a temporary connection or scaffolding to promote healing, but the interface of living to non-living materials soon breaks down under the stress of these applications, if it must bear the load more than acutely. Patients are thus disabled whose prostheses, defect size, or mere anatomy limit the availability or outcomes of such treatments. Our group developed the OrthoCoupler™ device to join skeletal muscle to prosthetic or natural structures without this interface breakdown. In this study, the goat knee extensor mechanism (quadriceps tendon, patella, and patellar tendon) was removed from the right hind limb in 16 goats. The device connected the quadriceps muscle to a stainless steel bone plate on the tibia. Mechanical testing and histology specimens were collected from each operated leg and contralateral unoperated control legs at 180 days. Maximum forces in the operated leg (vs. unoperated) were 1,400 ± 93 N (vs. 1,179 ± 61 N), linear stiffnesses were 33 ± 3 N/mm (vs. 37 ± 4 N/mm), and elongations at failure were 92.1 ± 5.3 mm (vs. 68.4 ± 3.8 mm; mean ± SEM). Higher maximum forces (p = 0.02) and elongations at failure (p=0.008) of legs with the device versus unoperated controls were significant; linear stiffnesses were not (p=0.3). We believe this technology will yield improved procedures for clinical challenges in orthopedic oncology, revision arthroplasty, tendon transfer, and tendon injury reconstruction. Copyright © 2011 Orthopaedic Research Society.

  2. Proteomic differences between native and tissue‐engineered tendon and ligament

    PubMed Central

    Tew, Simon R.; Peffers, Mandy; Canty‐Laird, Elizabeth G.; Comerford, Eithne

    2016-01-01

    Tendons and ligaments (T/Ls) play key roles in the musculoskeletal system, but they are susceptible to traumatic or age‐related rupture, leading to severe morbidity as well as increased susceptibility to degenerative joint diseases such as osteoarthritis. Tissue engineering represents an attractive therapeutic approach to treating T/L injury but it is hampered by our poor understanding of the defining characteristics of the two tissues. The present study aimed to determine differences in the proteomic profile between native T/Ls and tissue engineered (TE) T/L constructs. The canine long digital extensor tendon and anterior cruciate ligament were analyzed along with 3D TE fibrin‐based constructs created from their cells. Native tendon and ligament differed in their content of key structural proteins, with the ligament being more abundant in fibrocartilaginous proteins. 3D T/L TE constructs contained less extracellular matrix (ECM) proteins and had a greater proportion of cellular‐associated proteins than native tissue, corresponding to their low collagen and high DNA content. Constructs were able to recapitulate native T/L tissue characteristics particularly with regard to ECM proteins. However, 3D T/L TE constructs had similar ECM and cellular protein compositions indicating that cell source may not be an important factor for T/L tissue engineering. PMID:27080496

  3. Tendon tissue engineering: adipose-derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems.

    PubMed

    James, R; Kumbar, S G; Laurencin, C T; Balian, G; Chhabra, A B

    2011-04-01

    Tendon tissue engineering with a biomaterial scaffold that mimics the tendon extracellular matrix (ECM) and is biomechanically suitable, and when combined with readily available autologous cells, may provide successful regeneration of defects in tendon. Current repair strategies using suitable autografts and freeze-dried allografts lead to a slow repair process that is sub-optimal and fails to restore function, particularly in difficult clinical situations such as zone II flexor tendon injuries of the hand. We have investigated the effect of GDF-5 on cell proliferation and gene expression by primary rat adipose-derived stem cells (ADSCs) that were cultured on a poly(DL-lactide-co-glycolide) PLAGA fiber scaffold and compared to a PLAGA 2D film scaffold. The electrospun scaffold mimics the collagen fiber bundles present in native tendon tissue, and supports the adhesion and proliferation of multipotent ADSCs. Gene expression of scleraxis, the neotendon marker, was upregulated seven- to eightfold at 1 week with GDF-5 treatment when cultured on a 3D electrospun scaffold, and was significantly higher at 2 weeks compared to 2D films with or without GDF-5 treatment. Expression of the genes that encode the major tendon ECM protein, collagen type I, was increased by fourfold starting at 1 week on treatment with 100 ng mL(-1) GDF-5, and at all time points the expression was significantly higher compared to 2D films irrespective of GDF-5 treatment. Thus stimulation with GDF-5 can modulate primary ADSCs on a PLAGA fiber scaffold to produce a soft, collagenous musculoskeletal tissue that fulfills the need for tendon regeneration.

  4. Tendon tissue engineering: Adipose 1 derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems

    PubMed Central

    James, R; Kumbar, S G; Laurencin, C T; Balian, G; Chhabra, A B

    2011-01-01

    Tendon tissue engineering with a biomaterial scaffold that mimics the tendon extracellular matrix (ECM) and is biomechanically suitable when combined with readily available autologous cells may provide successful regeneration of defects in tendon. Current repair strategies using suitable autografts and freeze-dried allografts lead to a slow repair process that is sub-optimal and fails to restore function, particularly in difficult clinical situations such as zone II flexor tendon injuries of the hand. We have investigated the effect of GDF-5 on cell proliferation and gene expression by primary rat adipose-derived stromal cells (ADSCs) that were cultured on poly(DL-lactide-co-glycolide) PLAGA fiber scaffold and compared to PLAGA 2D film scaffold. The electrospun scaffold mimics the collagen fiber bundles present in native tendon tissue, and supports the adhesion and proliferation of multipotent ADSCs. Gene expression of scleraxis, the neotendon marker was upregulated 7 – 8 fold at 1 week with GDF-5 treatment when cultured on 3D electrospun scaffold, and was significantly higher at 2 weeks compared to 2D films with or without GDF-5 treatment. Expression of the genes that encode the major tendon ECM protein, collagen type I, was increased by 4 fold starting at 1 week on treatment with 100ng/mL GDF-5, and at all time points the expression was significantly higher compared to 2D films irrespective of GDF-5 treatment. Thus stimulation with GDF-5 can modulate primary ADSCs on PLAGA fiber scaffold to produce a soft, collagenous musculoskeletal tissue that fulfills the need for tendon regeneration. PMID:21436509

  5. Gait perturbation response in chronic anterior cruciate ligament deficiency and repair.

    PubMed

    Ferber, Reed; Osternig, Louis R; Woollacott, Marjorie H; Wasielewski, Noah J; Lee, Ji Hang

    2003-02-01

    To determine how chronic anterior cruciate ligament deficient and surgically repaired subjects react to unexpected forward perturbations during gait as compared to healthy controls. Gait testing of 10 chronic anterior cruciate ligament deficient subjects prior to and three months following reconstructive surgery, and 10 uninjured controls. The ability of an anterior cruciate ligament injured individual to react and maintain equilibrium during gait perturbations is critical for the prevention of reinjury. No studies have investigated how these individuals respond to unexpected perturbations during normal gait. An unexpected forward perturbation was induced upon heel strike using a force plate capable of translational movement. Prior to surgery, the anterior cruciate ligament subjects exhibited a greater knee extensor moment in response to the perturbation compared to healthy controls. Following surgery, the anterior cruciate ligament injured subjects exhibited a static knee position and a sustained knee extensor moment throughout stance in response to the perturbation as compared to controls. These data suggest that chronic anterior cruciate ligament deficient subjects rely heavily on knee extensor musculature to prevent collapse in response to an unexpected perturbation. This same reactive response was more pronounced 3 months following surgery. The results suggest that, prior to and following surgery, chronic anterior cruciate ligament injured subjects respond differently than healthy controls to an unexpected perturbation during gait. Anterior cruciate ligament injured or repaired subjects do not reduce or avoid vigorous contraction of the quadriceps muscles when responding to gait perturbations.

  6. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment

    PubMed Central

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-01-01

    Background: As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. Purpose: To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Study Design: Case series; Level of evidence, 4. Methods: Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Results: Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Conclusion: Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures. PMID:29479545

  7. Surface Modification with Chemically Modified Synovial Fluid for Flexor Tendon Reconstruction in a Canine Model in Vivo

    PubMed Central

    Ji, Xiaoxi; Reisdorf, Ramona L.; Thoreson, Andrew R.; Berglund, Lawrence R.; Moran, Steven L.; Jay, Gregory D.; An, Kai-Nan; Amadio, Peter C.; Zhao, Chunfeng

    2015-01-01

    Background: Functional restoration is the major concern after flexor tendon reconstruction in the hand. The purpose of the present study was to investigate the effects of modifying the surface of extrasynovial tendon autografts with carbodiimide-derivatized synovial fluid with gelatin (cd-SF-G) on functional outcomes of flexor tendon reconstruction using a canine model. Methods: The second and fifth flexor digitorum profundus tendons from eleven dogs were transected and repaired in zone II. The dogs then had six weeks of free activity leading to tendon rupture and scar formation (the repair-failure phase). In the reconstruction phase, two autologous peroneus longus tendons from each dog were harvested; one tendon was coated with cd-SF-G and the other, with saline solution, as a control. A non-weight-bearing rehabilitation protocol was followed for six weeks after reconstruction. The digits were then harvested and evaluations of function, adhesion status, gliding resistance, attachment strength, cell viability, and histology were performed. Results: The tendons coated with cd-SF-G demonstrated significantly lower values (mean and standard deviation) compared with the saline-solution group for work of flexion (0.63 ± 0.24 versus 1.34 ± 0.42 N-mm/deg), adhesion score (3.5 ± 1.6 versus 6.1 ± 1.3), proximal adhesion breaking force (8.6 ± 3.2 versus 20.2 ± 10.2 N), and gliding resistance (0.26 ± 0.08 versus 0.46 ± 0.22 N) (p < 0.05). There was no significant difference between the cd-SF-G and saline-solution groups (p > 0.05) in distal attachment-site strength (56.9 ± 28.4 versus 77.2 ± 36.2 N), stiffness (19 ± 7.5 versus 24.5 ± 14.5 N/mm), and compressive modulus from indentation testing (4.37 ± 1.26 versus 3.98 ± 1.24 N/mm). Histological analysis showed that tendons coated with cd-SF-G had smoother surfaces and demonstrated tendon-to-bone and tendon-to-tendon incorporation. No significant difference in viable cell count between the two groups was observed on tendon culture. Conclusions: Modification of the flexor tendon surface with cd-SF-G significantly improved digital function and reduced adhesion formation without affecting graft healing and stiffness. Clinical Relevance: This study used native synovial fluid as a basic lubricating reagent to treat a tendon graft in vivo, a novel avenue for improving clinical outcomes of flexor tendon reconstruction. This methodology may also apply to other surgical procedures where postoperative adhesions impair function. PMID:26085530

  8. A review on the use of cell therapy in the treatment of tendon disease and injuries

    PubMed Central

    Sawadkar, Prasad; Mudera, Vivek

    2014-01-01

    Tendon disease and injuries carry significant morbidity worldwide in both athletic and non-athletic populations. It is estimated that tendon injuries account for 30%−50% of all musculoskeletal injuries globally. Current treatments have been inadequate in providing an accelerated process of repair resulting in high relapse rates. Modern concepts in tissue engineering and regenerative medicine have led to increasing interest in the application of cell therapy for the treatment of tendon disease. This review will explore the use of cell therapy, by bringing together up-to-date evidence from in vivo human and animal studies, and discuss the issues surrounding the safety and efficacy of its use in the treatment of tendon disease. PMID:25383170

  9. [Neglected ipsilateral simultaneous ruptures of patellar and quadriceps tendon].

    PubMed

    Karahasanoğlu, İlker; Yoloğlu, Osman; Kerimoğlu, Servet; Turhan, Ahmet Uğur

    2015-01-01

    Neglected patellar and quadriceps tendon rupture is a rare injury, but ipsilateral simultaneous patellar and quadriceps tendon rupture was not described in the literature to our knowledge. In this article, we report a 40-year-old healthy male patient with neglected ipsilateral patellar and quadriceps tendon ruptures treated by peroneus longus tendon autograft. Patient had received some conservative and surgical treatments for patellar fracture before applying to our clinic. After our treatment using peroneus longus autograft and interference nails, patient was immobilized for six weeks in cylindrical cast. Flexion exercises and full weight bearing were started after cast removal. Patient had no complaint at postoperative second year. Patient was a neglected case. Surgical repair and early rehabilitation enabled us to achieve a satisfactory outcome.

  10. Surgical and nonsurgical treatment of total rupture of the pectoralis major muscle in athletes: update and critical appraisal.

    PubMed

    Kircher, Jörn; Ziskoven, Christoph; Patzer, Thilo; Zaps, Daniela; Bittersohl, Bernd; Krauspe, Rüdiger

    2010-10-11

    The complete rupture of the pectoralis major tendon is an uncommon injury but has become increasingly common among athletes in recent years. This may be due to a higher number of individuals taking part in high-impact sports and weightlifting as well as the use of anabolic substances, which can make muscles and tendons vulnerable to injury. In recent literature, there are only few recommendations to rely on conservative treatment alone, but there are a number of reports and case series recommending early surgical intervention. Comparing the results of the two treatment regimens, there is clear evidence for a superior outcome after surgical repair with better cosmesis, better functional results, regaining of muscle power, and return to sports compared with the conservative treatment. In summary, anatomic surgical repair is the treatment of choice for complete acute ruptures of the pectoralis major tendon or muscle in athletes.

  11. Acute distal biceps rupture in an adolescent weightlifter on chronic steroid suppression: a case report.

    PubMed

    Ding, David Y; LaMartina, Joey A; Zhang, Alan L; Pandya, Nirav K

    2016-09-01

    Distal biceps tendon ruptures are uncommon events in the adult population and exceedingly rare in the adolescent population. To the best of our knowledge, this is the first and only report of a distal biceps tendon rupture in an adolescent with a history of chronic corticosteroid suppression. We present a case of a 17-year-old male on chronic corticosteroid suppression who underwent a successful distal biceps tendon repair after an acute rupture following weightlifting. At the 1-year follow-up, the patient reports full range of motion and strength, and is able to return to his preinjury activity level with sports and weightlifting. Acute distal biceps ruptures are uncommon injuries in the pediatric population, but may occur in conjunction with chronic corticosteroid use. Anatomic repair, when possible, can restore function and strength. level IV, case report.

  12. IN VIVO MEASURES OF SHEAR WAVE SPEED AS A PREDICTOR OF TENDON ELASTICITY AND STRENGTH

    PubMed Central

    Martin, Jack A.; Biedrzycki, Adam H.; Lee, Kenneth S.; DeWall, Ryan J.; Brounts, Sabrina H.; Murphy, William L.; Markel, Mark D.; Thelen, Darryl G.

    2015-01-01

    The purpose of this study was to assess the potential for ultrasound shear wave elastography (SWE) to assess tissue elasticity and ultimate stress in both intact and healing tendons. The lateral gastrocnemius (Achilles) tendons of 41 New Zealand white rabbits were surgically severed and repaired with growth factor coated sutures. SWE imaging was used to measure shear wave speed (SWS) in both the medial and lateral tendons pre-surgery, and at 2 and 4 weeks post-surgery. Rabbits were euthanized at 4 weeks, and both medial and lateral tendons underwent mechanical testing to failure. SWS significantly (p<0.001) decreased an average of 17% between the intact and post-surgical state across all tendons. SWS was significantly (p<0.001) correlated with both the tendon elastic modulus (r = 0.52) and ultimate stress (r = 0.58). Thus, ultrasound SWE is a potentially promising noninvasive technology for quantitatively assessing the mechanical integrity of pre-operative and post-operative tendons. PMID:26215492

  13. An overview of structure, mechanical properties, and treatment for age-related tendinopathy.

    PubMed

    Zhou, B; Zhou, Y; Tang, K

    2014-04-01

    Tendons transfer tensile loads from muscle to bone, which enable joint motions and stabilize joints. Tendons sustain large mechanical loads in vivo and as a result, tendons were frequently injured. Aging has been confirmed as a predisposing factor of tendinopathy and bad recovery quality following tendon repair. Current treatment methods are generally not effective and involve either symptomatic relief with non-steroidal antiinflammatory drugs and physical therapy or surgery when conservative treatments failed. The limitation in treatment options is due to our incomplete knowledge of age-related tendinopathy. Studies over the past decades have uncovered a number of important mechanical and cellular changes of aging tendon. However, the basis of aging as a major risk factor for tendon injury and impaired tendon healing remained poorly understood. The objectives of this review are to provide an overview of the current knowledge about the aging-associated changes of structure, mechanical properties and treatment in tendon and highlight causes and therapies for age-related tendinopathy.

  14. Characterizing the macro and micro mechanical properties of scaffolds for rotator cuff repair.

    PubMed

    Smith, Richard D J; Zargar, Nasim; Brown, Cameron P; Nagra, Navraj S; Dakin, Stephanie G; Snelling, Sarah J B; Hakimi, Osnat; Carr, Andrew

    2017-11-01

    Retearing after rotator cuff surgery is a major clinical problem. Numerous scaffolds are being used to try to reduce retear rates. However, few have demonstrated clinical efficacy. We hypothesize that this lack of efficacy is due to insufficient mechanical properties. Therefore, we compared the macro and nano/micro mechanical properties of 7 commercially available scaffolds to those of the human supraspinatus tendons, whose function they seek to restore. The clinically approved scaffolds tested were X-Repair, LARS ligament, Poly-Tape, BioFiber, GraftJacket, Permacol, and Conexa. Fresh frozen cadaveric human supraspinatus tendon samples were used. Macro mechanical properties were determined through tensile testing and rheometry. Scanning probe microscopy and scanning electron microscopy were performed to assess properties of materials at the nano/microscale (morphology, Young modulus, loss tangent). None of the scaffolds tested adequately approximated both the macro and micro mechanical properties of human supraspinatus tendon. Macroscale mechanical properties were insufficient to restore load-bearing function. The best-performing scaffolds on the macroscale (X-Repair, LARS ligament) had poor nano/microscale properties. Scaffolds approximating tendon properties on the nano/microscale (BioFiber, biologic scaffolds) had poor macroscale properties. Existing scaffolds failed to adequately approximate the mechanical properties of human supraspinatus tendons. Combining the macroscopic mechanical properties of a synthetic scaffold with the micro mechanical properties of biologic scaffold could better achieve this goal. Future work should focus on advancing techniques to create new scaffolds with more desirable mechanical properties. This may help improve outcomes for rotator cuff surgery patients. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. Rotator cuff repair using cell sheets derived from human rotator cuff in a rat model.

    PubMed

    Harada, Yoshifumi; Mifune, Yutaka; Inui, Atsuyuki; Sakata, Ryosuke; Muto, Tomoyuki; Takase, Fumiaki; Ueda, Yasuhiro; Kataoka, Takeshi; Kokubu, Takeshi; Kuroda, Ryosuke; Kurosaka, Masahiro

    2017-02-01

    To achieve biological regeneration of tendon-bone junctions, cell sheets of human rotator-cuff derived cells were used in a rat rotator cuff injury model. Human rotator-cuff derived cells were isolated, and cell sheets were made using temperature-responsive culture plates. Infraspinatus tendons in immunodeficient rats were resected bilaterally at the enthesis. In right shoulders, infraspinatus tendons were repaired by the transosseous method and covered with the cell sheet (sheet group), whereas the left infraspinatus tendons were repaired in the same way without the cell sheet (control group). Histological examinations (safranin-O and fast green staining, isolectin B4, type II collagen, and human-specific CD31) and mRNA expression (vascular endothelial growth factor; VEGF, type II collagen; Col2, and tenomodulin; TeM) were analyzed 4 weeks after surgery. Biomechanical tests were performed at 8 weeks. In the sheet group, proteoglycan at the enthesis with more type II collagen and isolectin B4 positive cells were seen compared with in the control group. Human specific CD31-positive cells were detected only in the sheet group. VEGF and Col2 gene expressions were higher and TeM gene expression was lower in the sheet group than in the control group. In mechanical testing, the sheet group showed a significantly higher ultimate failure load than the control group at 8 weeks. Our results indicated that the rotator-cuff derived cell sheet could promote cartilage regeneration and angiogenesis at the enthesis, with superior mechanical strength compared with the control. Treatment for rotator cuff injury using cell sheets could be a promising strategy for enthesis of tendon tissue engineering. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:289-296, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. Ten-year clinical and anatomic follow-up after repair of anterosuperior rotator cuff tears: influence of the subscapularis.

    PubMed

    Nové-Josserand, Laurent; Collin, Philippe; Godenèche, Arnaud; Walch, Gilles; Meyer, Nicolas; Kempf, Jean-Francois

    2017-10-01

    Anterosuperior rotator cuff tears are more frequent than expected. We report the results of a 10-year follow-up study after repair. Our hypothesis was that the extent of the subscapularis tear influenced the prognosis. The study population consisted of all 138 patients who underwent surgery in 14 participating centers in 2003 for full-thickness tears of the rotator cuff with lesions in the subscapularis and supraspinatus tendons. The patients were divided into 2 groups, depending on whether the subscapularis lesion affected only the superior half of the tendon (group A) or extended into the lower half (group B). Ninety-two patients (56 ± 7 years; 71 in group A and 21 in group B) were available for follow-up after 10 years (127 ± 16 months) with magnetic resonance imaging to evaluate tendon healing and muscle condition. The mean Constant scores were 59 ± 16 before surgery and 77 ± 14 at follow-up (P = 1.7 × 10 -12 ). The retear rates were 25% for the supraspinatus and 13.5% for the subscapularis tendon. The clinical results for group A patients were better than those for group B. Severe fatty infiltration was observed more frequently in the subscapularis than in the supraspinatus muscle (27% vs. 12% of cases). Supraspinatus healing influenced subscapularis healing and fatty infiltration. Repair of anterosuperior rotator cuff tears is satisfactory at 10 years, particularly if the subscapularis tear is not extensive. An extensive subscapularis tear is a negative prognosis factor. Postoperatively, fatty infiltration of the subscapularis muscle was frequently observed despite tendon healing. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Arthroscopic Rotator Cuff Repair With Graft Augmentation of 3-Dimensional Biological Collagen for Moderate to Large Tears: A Randomized Controlled Study.

    PubMed

    Cai, You-Zhi; Zhang, Chi; Jin, Ri-Long; Shen, Tong; Gu, Peng-Cheng; Lin, Xiang-Jin; Chen, Jian-De

    2018-05-01

    Due to the highly organized tissue and avascular nature of the rotator cuff, rotator cuff tears have limited ability to heal after the tendon is reinserted directly on the greater tubercle of the humerus. Consequently, retears are among the most common complications after rotator cuff repair. Augmentation of rotator cuff repairs with patches has been an active area of research in recent years to reduce retear rate. Graft augmentation with 3D collagen could prevent retears of the repaired tendon and improve tendon-bone healing in moderate to large rotator cuff tears. Randomized controlled study; Level of evidence, 2. A prospective, randomized controlled study was performed in a consecutive series of 112 patients age 50 to 85 years who underwent rotator cuff repair with the suture-bridge technique (58 patients, control group) or the suture-bridge technique augmented with 3-dimensional (3D) collagen (54 patients, study group). All patients were followed for 28.2 months (range, 24-36 months). Visual analog scale score for pain, University of California Los Angeles (UCLA) shoulder score, and Constant score were determined. Magnetic resonance imaging was performed pre- and postoperatively (at a minimum of 24 months) to evaluate the integrity of the rotator cuff and the retear rate of the repaired tendon. Three patients in each group had biopsies at nearly 24 months after surgery with histological assessment and transmission electron microscopy. A total of 104 patients completed the final follow-up. At the 12-month follow-up, the UCLA shoulder score was 28.1 ± 1.9 in the study group, which was significantly better than that in the control group (26.9 ± 2.1, P = .002). The Constant score was also significantly better in the study group (87.1 ± 3.2) than in the control group (84.9 ± 4.2, P = .003). However, at the final follow-up, no significant differences were found in the UCLA shoulder scores (29.4 ± 1.9 in the control group and 30.0 ± 1.6 in the study group, P = .052) or Constant scores (89.9 ± 3.2 in the control group and 90.8 ± 3.5 in the study group, P = .18). In terms of structural integrity, more patients in the study group had a favorable type I retear grade (18/51) than in the control group (10/53) ( P = .06). The postoperative retear rate was 34.0% in the control group and 13.7% in the study group, thus indicating a significantly lower retear rate in the study group ( P = .02). Biopsy specimens of the tendon-bone interface in 6 patients revealed more bone formation and more aligned fibers with larger diameters in the study group than in the control group. No intraoperative or postoperative complications were noted in either group. 3D collagen augmentation could provide effective treatment of moderate to large rotator cuff tears, providing substantial functional improvement, and could reduce the retear rate. This technique could also promote new tendon-bone formation, thus exerting a prominent effect on tendon-bone healing.

  18. A comparative clinical evaluation of arthroscopic single-row versus double-row supraspinatus tendon repair.

    PubMed

    Buess, Eduard; Waibl, Bernhard; Vogel, Roger; Seidner, Robert

    2009-10-01

    Cadaveric studies and commercial pressure have initiated a strong trend towards double-row repair in arthroscopic cuff surgery. The objective of this study was to evaluate if the biomechanical advantages of a double-row supraspinatus tendon repair would result in superior clinical outcome and higher abduction strength. A retrospective study of two groups of 32 single-row and 33 double-row repairs of small to medium cuff tears was performed. The Simple Shoulder Test (SST) and a visual analog scale for pain were used to evaluate the outcome. The participation rate was 100%. A subset of patients was further investigated with the Constant Score (CS) including electronic strength measurement. The double-row repair patients had significantly more (p = 0.01) yes answers in the SST than the single-row group, and pain reduction was slightly better (p = 0.03). No difference was found for the relative CS (p = 0.86) and abduction strength (p = 0.74). Patient satisfaction was 100% for double-row and 97% for single-row repair. Single- and double-row repairs both achieved excellent clinical results. Evidence of superiority of double-row repair is still scarce and has to be balanced against the added complexity of the procedure and higher costs.

  19. Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model.

    PubMed

    Quigley, Ryan J; Gupta, Akash; Oh, Joo-Han; Chung, Kyung-Chil; McGarry, Michelle H; Gupta, Ranjan; Tibone, James E; Lee, Thay Q

    2013-08-01

    The transosseous-equivalent (TOE) rotator cuff repair technique increases failure loads and contact pressure and area between tendon and bone compared to single-row (SR) and double-row (DR) repairs, but no study has investigated if this translates into improved healing in vivo. We hypothesized that a TOE repair in a rabbit chronic rotator cuff tear model would demonstrate a better biomechanical profile than SR and DR repairs after 12 weeks of healing. A two-stage surgical procedure was performed on 21 New Zealand White Rabbits. The right subscapularis tendon was transected and allowed to retract for 6 weeks to simulate a chronic tear. Repair was done with the SR, DR, or TOE technique and allowed to heal for 12 weeks. Cyclic loading and load to failure biomechanical testing was then performed. The TOE repair showed greater biomechanical characteristics than DR, which in turn were greater than SR. These included yield load (p < 0.05), energy absorbed to yield (p < 0.05), and ultimate load (p < 0.05). For repair of a chronic, retracted rotator cuff tear, the TOE technique was the strongest biomechanical construct after healing followed by DR with SR being the weakest. Copyright © 2013 Orthopaedic Research Society.

  20. The effect of postoperative passive motion on rotator cuff healing in a rat model.

    PubMed

    Peltz, Cathryn D; Dourte, Leann M; Kuntz, Andrew F; Sarver, Joseph J; Kim, Soung-Yon; Williams, Gerald R; Soslowsky, Louis J

    2009-10-01

    Surgical repairs of torn rotator cuff tendons frequently fail. Immobilization has been shown to improve tissue mechanical properties in an animal model of rotator cuff repair, and passive motion has been shown to improve joint mechanics in animal models of flexor tendon repair. Our objective was to determine if daily passive motion would improve joint mechanics in comparison with continuous immobilization in a rat rotator cuff repair model. We hypothesized that daily passive motion would result in improved passive shoulder joint mechanics in comparison with continuous immobilization initially and that there would be no differences in passive joint mechanics or insertion site mechanical properties after four weeks of remobilization. A supraspinatus injury was created and was surgically repaired in sixty-five Sprague-Dawley rats. Rats were separated into three postoperative groups (continuous immobilization, passive motion protocol 1, and passive motion protocol 2) for two weeks before all underwent a remobilization protocol for four weeks. Serial measurements of passive shoulder mechanics (internal and external range of motion and joint stiffness) were made before surgery and at two and six weeks after surgery. After the animals were killed, collagen organization and mechanical properties of the tendon-to-bone insertion site were determined. Total range of motion for both passive motion groups (49% and 45% of the pre-injury values) was less than that for the continuous immobilization group (59% of the pre-injury value) at two weeks and remained significantly less following four weeks of remobilization exercise. Joint stiffness at two weeks was increased for both passive motion groups in comparison with the continuous immobilization group. At both two and six weeks after repair, internal range of motion was significantly decreased whereas external range of motion was not. There were no differences between the groups in terms of collagen organization or mechanical properties. In this model, immediate postoperative passive motion was found to be detrimental to passive shoulder mechanics. We speculate that passive motion results in increased scar formation in the subacromial space, thereby resulting in decreased range of motion and increased joint stiffness. Passive motion had no effect on collagen organization or tendon mechanical properties measured six weeks after surgery.

Top