Orthodontic skeletal anchorage using a palatal external plate.
Kobayashi, Masaru; Fushima, Kenji
2014-03-01
We have developed the Anchor-Lock external plate system, which is fitted on the palate for the purpose of orthodontic skeletal anchorage. The aim of this study was to introduce the Anchor-Lock and assess its success rate. The Anchor-Lock is composed of titanium screws of 2·0-mm diameter and a titanium plate of 1·0-mm thickness. The external plate is rigidly interlocked with the heads of the screws, which are implanted trans-mucosally into palatal bone. Three types of Anchor-Lock are available. These were applied to 137 orthodontic patients (104 females and 33 males) aged 10-54 years. Two types of plate were used, a straight-shaped plate applied to the hard palate and to the anterior palate and a double-Y-shaped plate applied after tooth-borne rapid maxillary expansion. Success rate of the Anchor-Lock was 92·0% overall. No significant difference in success rate was found by age or sex of patients. Type or screw length of the Anchor-Lock did not affect success rate significantly. Success rate was significantly increased by the use of the surgical stent. The Anchor-Lock was effectively applied to distalize and/or intrude the upper molars. The Anchor-Lock system appears suitable for clinical use as an alternative to conventional screw- and plate-type orthodontic implants.
Euler Strut: A Mechanical Analogy for Dynamics in the Vicinity of a Critical Point
ERIC Educational Resources Information Center
Bobnar, Jaka; Susman, Katarina; Parsegian, V. Adrian; Rand, Peter R.; Cepic, Mojca; Podgornik, Rudolf
2011-01-01
An anchored elastic filament (Euler strut) under an external point load applied to its free end is a simple model for a second-order phase transition. In the static case, a load greater than the critical load causes a Euler buckling instability, leading to a change in the filament's shape. The analysis of filament dynamics with an external point…
Physiologically Relevant Prosthetic Limb Movement Feedback for Upper and Lower Extremity Amputees
2016-10-01
upper arm (elbow movement), Upper leg (knee movement) and lower leg ( ankle movement) to provide a physiologically relevant sense of limb movement...Additionally a BOA cable tensioning system is passed through these plates and anchored to the external surface of the socket. When tension is applied the
Ono, Y.; Woodmass, J. M.; Nelson, A. A.; Boorman, R. S.; Thornton, G. M.
2016-01-01
Objectives This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Methods Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’. Results In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed ‘suture cutting through bone’ as the predominant source of suture displacement in cadaveric bone (qualitative) and greater ‘suture cutting through bone’ comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Conclusions Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone. Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269–275. DOI: 10.1302/2046-3758.56.2000535. PMID:27357383
Ono, Y; Woodmass, J M; Nelson, A A; Boorman, R S; Thornton, G M; Lo, I K Y
2016-06-01
This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of 'suture cutting through bone'. In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed 'suture cutting through bone' as the predominant source of suture displacement in cadaveric bone (qualitative) and greater 'suture cutting through bone' comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone.Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269-275. DOI: 10.1302/2046-3758.56.2000535. © 2016 Lo et al.
Further Study of the Choice of Anchor Tests in Equating
ERIC Educational Resources Information Center
Trierweiler, Tammy J.; Lewis, Charles; Smith, Robert L.
2016-01-01
In this study, we describe what factors influence the observed score correlation between an (external) anchor test and a total test. We show that the anchor to full-test observed score correlation is based on two components: the true score correlation between the anchor and total test, and the reliability of the anchor test. Findings using an…
Modified method for external attachment of transmitters to birds using two subcutaneous anchors
Lewis, T.L.; Flint, Paul L.
2008-01-01
Of the transmitter attachment techniques for birds, the subcutaneous anchor provides a secure attachment that yields relatively few secondary effects. However, the use of subcutaneous anchors has been limited by transmitter size and retention time. Using a modified method of attachment that utilized two subcutaneous anchors, we deployed 69 GPS transmitters, plus 13 VHF transmitters that were similar in size and weight to GPS models, on Pacific Black Brant (Branta bernicla nigricans). Prior to our study, only harnesses were used for attaching GPS transmitters on birds, mainly because GPS transmitters are too large for other external attachment techniques and implantation in the body cavity attenuates the GPS signal. Thus, to increase the size capacity of anchor attachment and to avoid the well-documented negative effects of harnesses on behavior and survival, we added a second anchor at the transmitter's posterior end. The double-anchor attachment technique was quickly and easily accomplished in the field, requiring bird handling times of <10 min. Incidental recoveries of tagged Brant indicate a high degree of transmitter retention. Five recaptured birds (4-6 weeks after deployment) and eight killed by hunters (3-6 mo after deployment) retained their GPS transmitters. For studies involving the use of relatively large transmitters, the double-anchor method appears to provide a viable alternative for external attachment. ?? 2008 Association of Field Ornithologists.
Follow Your Heart: How Is Willingness to Pay Formed under Multiple Anchors?
Lin, Chien-Huang; Chen, Ming
2017-01-01
In sales, a common promotional tactic is to supplement a required purchase (i.e., a focal product) by offering a free or discounted product (i.e., a supplementary product). The present research examines the contextual factors driving consumer evaluations of the supplementary product after the promotion has been terminated. Two experiments are used to demonstrate that consumers use multiple anchors to determine the value of a supplementary product. Consumers use other types of price information, such as the internal reference price (IRP), promotional price, and original price of the supplementary product, as anchors to adjust their willingness to pay. Among the multiple anchors, the consumer’s IRP is not only the crucial anchor to estimate the willingness to pay but also the criterion to determine whether other price information can serve as anchors. Price information, such as the promotional and original price of the supplementary product, which is higher (lower) than the IRP, will increase (decrease) the willingness to pay. However, these anchors are only employed when the price information is considered to be plausible. Assimilation and contrast effects occur when the IRP is used by consumers as a criterion to judge the reasonableness of other anchors. When the external price information belongs (does not belong) to consumers’ distribution of IRP, assimilation (contrast) effects occur, and consumers will regard the external reference price (ERP) to be a plausible (implausible) price. Limitations and future avenues for research are also discussed. PMID:29312098
Follow Your Heart: How Is Willingness to Pay Formed under Multiple Anchors?
Lin, Chien-Huang; Chen, Ming
2017-01-01
In sales, a common promotional tactic is to supplement a required purchase (i.e., a focal product) by offering a free or discounted product (i.e., a supplementary product). The present research examines the contextual factors driving consumer evaluations of the supplementary product after the promotion has been terminated. Two experiments are used to demonstrate that consumers use multiple anchors to determine the value of a supplementary product. Consumers use other types of price information, such as the internal reference price (IRP), promotional price, and original price of the supplementary product, as anchors to adjust their willingness to pay. Among the multiple anchors, the consumer's IRP is not only the crucial anchor to estimate the willingness to pay but also the criterion to determine whether other price information can serve as anchors. Price information, such as the promotional and original price of the supplementary product, which is higher (lower) than the IRP, will increase (decrease) the willingness to pay. However, these anchors are only employed when the price information is considered to be plausible. Assimilation and contrast effects occur when the IRP is used by consumers as a criterion to judge the reasonableness of other anchors. When the external price information belongs (does not belong) to consumers' distribution of IRP, assimilation (contrast) effects occur, and consumers will regard the external reference price (ERP) to be a plausible (implausible) price. Limitations and future avenues for research are also discussed.
ERIC Educational Resources Information Center
Puhan, Gautam; vonDavier, Alina; Gupta, Shaloo
2008-01-01
Equating under the external anchor design is frequently conducted using scaled scores on the anchor test. However, scaled scores often lead to the unique problem of creating zero frequencies in the score distribution because there may not always be a one-to-one correspondence between raw and scaled scores. For example, raw scores of 17 and 18 may…
Two-stage removal of an impacted foreign body with an epoxied anchor.
Isaacson, Glenn
2003-09-01
A stone impacted in a child's external auditory canal had defied all conventional means of removal. It was extracted successfully after attachment of a specially formed metal anchor with epoxy glue. The technique of and rationale for this approach are discussed.
Thermographic inspection of external thermal insulation systems with mechanical fixing
NASA Astrophysics Data System (ADS)
Simões, Nuno; Simões, Inês; Serra, Catarina; Tadeu, António
2015-05-01
An External Thermal Insulation Composite System (ETICS) kit may include anchors to mechanically fix the insulation product onto the wall. Using this option increases safety when compared to a simple bonded solution, however, it is more expensive and needs higher labor resources. The insulation product is then coated with rendering, which applied to the insulation material without any air gap. The rendering comprises one or more layers of coats with an embedded reinforcement. The most common multi-coat rendering system presents a base coat applied directly to the insulation product with a glass fiber mesh as reinforcement, followed by a second base coat, before a very thin coat (key coat) that prepares the surface to receive the finishing and decorative coat. The thickness of the rendering system may vary between around 5 to 10 mm. The higher thicknesses may be associated with a reinforcement composed by two layers of glass fiber mesh. The main purpose of this work is to apply infrared thermography (IRT) techniques to 2 ETICS solution (single or double layer of glass fiber mesh) and evaluate its capability in the detection of anchors. The reliability of IRT was tested using an ETICS configuration of expanded cork boards and a rendering system with one or two layers of glass fiber mesh. An active thermography approach was performed in laboratory conditions, in transmission and reflection mode. In the reflection mode halogen lamps and air heater were employed as the thermal stimulus. Air heater was also the source used in the transmission mode tests. The resulting data was processed in both time and frequency domains. In this last approach, phase contrast images were generated and studied.
The Effect of Differential Motivation on IRT Linking
ERIC Educational Resources Information Center
Mittelhaëuser, Marie-Anne; Béguin, Anton A.; Sijtsma, Klaas
2015-01-01
The purpose of this study was to investigate whether simulated differential motivation between the stakes for operational tests and anchor items produces an invalid linking result if the Rasch model is used to link the operational tests. This was done for an external anchor design and a variation of a pretest design. The study also investigated…
Yesil, Fatma; Suwa, Masayori; Tsukahara, Satoshi
2018-01-09
We constructed the apparatus to observe the Fréedericksz transition of liquid crystal in contact with water. The Fréedericksz transition is a distortion of nematic liquid crystals (LCs) induced by external fields. In the present system, sweeping homogeneous magnetic field was applied to the sample, and the distortion of the LC was visualized with a polarized light microscope with the crossed Nichols configuration. The anchoring energy (W AQ/LC ) at the aqueous phase/LC interface was measured in the presence of surfactant from the threshold magnetic field of the Fréedericksz transition. We studied two cationic surfactants: dodecyltrimethylammonium bromide and tetradecyltrimethylammonium bromide. A nematic LC, 4-cyano-4'-pentylbiphenyl (5CB), was examined, which was confined in a copper grid on an octadecyltrichlorosilane-treated microscope glass plate. Measured W AQ/LC were reproducible and showed consistence with the reported region for the water/LC interface. Interfacial excess of surfactants was also measured by the pendant drop method, and the relationship between the obtained W AQ/LC and the interfacial excess was investigated. Experiments showed that an increase in the anchoring energy depends on the surfactant and its interfacial excess. The region of the interfacial coverage, at which W AQ/LC increases, varied with the chain length of the surfactant. The measurement of the anchoring energy will provide new fundamental information on aqueous phase/LC interface.
Schuller, Wouter; Ostelo, Raymond W J G; Janssen, Richard; de Vet, Henrica C W
2014-04-15
Reported values of the minimal important change (MIC) and the smallest detectable change (SDC) for the neck disability index (NDI) differ strongly, raising questions about the generalizability of these parameters. The SDC and the MIC are possibly influenced by the study design or by the study population. We studied the influence of the type of anchor, the definition of improvement and population characteristics on the SDC and the MIC of the NDI. A cohort study including 101 patients with non-specific, chronic neck pain. SDC and MIC were calculated using two types of external anchors. For each anchor we applied two different definitions to dichotomize the population into improved and unimproved patients. The influence of patient characteristics was assessed in relevant subgroups: patients with or without radiating pain and patients with different baseline scores. The influence of different anchors and different definitions of improvement on estimates of the SDC and the MIC was only minimal. The SDC and the MIC were similar for subgroups of patients with or without radiation, but differed strongly for subgroups of patients with higher or lower baseline scores. Our study shows that estimates of the SDC and the MIC of the NDI can be influenced by population characteristics. It is concluded that we cannot adopt a single change score to define relevant change by combining the result of previous studies.
Unlocking Hospitality Managers Career Transitions through Applying Schein's Career Anchors Theory
ERIC Educational Resources Information Center
McGuire, David; Polla, Giovana; Heidl, Britta
2017-01-01
Purpose: This paper seeks to unlock the career transitions of hospitality managers through applying Schein's career anchors theory. It seeks to understand how Schein's Career Anchors help explain the career transitions of managers in the Scottish hospitality industry. Design/methodology/approach: The paper adopts a non-sequential multi-method…
A Brief Report on How Impossible Scores Affect Smoothing and Equating
ERIC Educational Resources Information Center
Puhan, Gautam; von Davier, Alina A.; Gupta, Shaloo
2010-01-01
Equating under the external anchor design is frequently conducted using scaled scores on the anchor test. However, scaled scores often lead to the unique problem of creating zero frequencies in the score distribution because there may not always be a one-to-one correspondence between raw and scaled scores. For example, raw scores of 17 and 18 may…
Electro-responsive polyelectrolyte-coated surfaces.
Sénéchal, V; Saadaoui, H; Rodriguez-Hernandez, J; Drummond, C
2017-07-01
The anchoring of polymer chains at solid surfaces is an efficient way to modify interfacial properties like the stability and rheology of colloidal dispersions, lubrication and biocompatibility. Polyelectrolytes are good candidates for the building of smart materials, as the polyion chain conformation can often be tuned by manipulation of different physico-chemical variables. However, achieving efficient and reversible control of this process represents an important technological challenge. In this regard, the application of an external electrical stimulus on polyelectrolytes seems to be a convenient control strategy, for several reasons. First, it is relatively easy to apply an electric field to the material with adequate spatiotemporal control. In addition, in contrast to chemically induced changes, the molecular response to a changing electric field occurs relatively quickly. If the system is properly designed, this response can then be used to control the magnitude of surface properties. In this work we discuss the effect of an external electric field on the adhesion and lubrication properties of several polyelectrolyte-coated surfaces. The influence of the applied field is investigated at different pH and salt conditions, as the polyelectrolyte conformation is sensitive to these variables. We show that it is possible to fine tune friction and adhesion using relatively low applied fields.
Shearing-induced asymmetry in entorhinal grid cells.
Stensola, Tor; Stensola, Hanne; Moser, May-Britt; Moser, Edvard I
2015-02-12
Grid cells are neurons with periodic spatial receptive fields (grids) that tile two-dimensional space in a hexagonal pattern. To provide useful information about location, grids must be stably anchored to an external reference frame. The mechanisms underlying this anchoring process have remained elusive. Here we show in differently sized familiar square enclosures that the axes of the grids are offset from the walls by an angle that minimizes symmetry with the borders of the environment. This rotational offset is invariably accompanied by an elliptic distortion of the grid pattern. Reversing the ellipticity analytically by a shearing transformation removes the angular offset. This, together with the near-absence of rotation in novel environments, suggests that the rotation emerges through non-coaxial strain as a function of experience. The systematic relationship between rotation and distortion of the grid pattern points to shear forces arising from anchoring to specific geometric reference points as key elements of the mechanism for alignment of grid patterns to the external world.
ERIC Educational Resources Information Center
Lu, Ru; Haberman, Shelby; Guo, Hongwen; Liu, Jinghua
2015-01-01
In this study, we apply jackknifing to anchor items to evaluate the impact of anchor selection on equating stability. In an ideal world, the choice of anchor items should have little impact on equating results. When this ideal does not correspond to reality, selection of anchor items can strongly influence equating results. This influence does not…
Career Paths, Images and Anchors: A Study with Brazilian Professionals
ERIC Educational Resources Information Center
Kilimnik, Zelia Miranda; de Oliveira, Luiz Claudio Vieira; Sant'anna, Anderson De Souza; Barros, Delba Teixeira Rodrigues
2011-01-01
This article analyses career anchors changes associated to images and professionals trajectories. Its main question: Do anchors careers change through time? We conducted twelve interviews involving professionals from the Administration Area, applying Schein's Career Anchors Inventory (1993). We did the same two years later. In both of them, the…
Retention of internal anchor tags by juvenile striped bass
Van Den Avyle, M.J.; Wallin, J.E.
2001-01-01
We marked hatchery-reared striped bass Morone saxatilis (145-265 mm total length) with internal anchor tags and monitored retention for 28 months after stocking in the Savannah River, Georgia and South Carolina. Anchor tags (with an 18-mm, T-shaped anchor and 42-mm streamer) were surgically implanted ventrally, and coded wire tags (1 mm long and 0.25 mm in diameter) were placed into the cheek muscle to help identify subsequent recaptures. The estimated probability of retention (SD) of anchor tags was 0.94 (0.05) at 4 months, 0.64 (0.13) at 16 months, and 0.33 (0.19) at 28 months. Of 10 fish recaptured with only coded wire tags, 5 showed an externally visible wound or scar near the point of anchor tag insertion. The incidence of wounds or scars, which we interpreted as evidence of tag shedding, increased to 50% in recaptures taken at 28 months (three of six fish). Our estimates for retention of anchor tags were generally lower than those in other studies of striped bass, possibly because of differences in the style of anchor or sizes of fish used. Because of its low rate of retention, the type of anchor tag we used may not be suitable for long-term assessments of stock enhancement programs that use striped bass of the sizes we evaluated.
New force replica exchange method and protein folding pathways probed by force-clamp technique.
Kouza, Maksim; Hu, Chin-Kun; Li, Mai Suan
2008-01-28
We have developed a new extended replica exchange method to study thermodynamics of a system in the presence of external force. Our idea is based on the exchange between different force replicas to accelerate the equilibrium process. This new approach was applied to obtain the force-temperature phase diagram and other thermodynamical quantities of the three-domain ubiquitin. Using the C(alpha)-Go model and the Langevin dynamics, we have shown that the refolding pathways of single ubiquitin depend on which terminus is fixed. If the N end is fixed then the folding pathways are different compared to the case when both termini are free, but fixing the C terminal does not change them. Surprisingly, we have found that the anchoring terminal does not affect the pathways of individual secondary structures of three-domain ubiquitin, indicating the important role of the multidomain construction. Therefore, force-clamp experiments, in which one end of a protein is kept fixed, can probe the refolding pathways of a single free-end ubiquitin if one uses either the polyubiquitin or a single domain with the C terminus anchored. However, it is shown that anchoring one end does not affect refolding pathways of the titin domain I27, and the force-clamp spectroscopy is always capable to predict folding sequencing of this protein. We have obtained the reasonable estimate for unfolding barrier of ubiquitin, using the microscopic theory for the dependence of unfolding time on the external force. The linkage between residue Lys48 and the C terminal of ubiquitin is found to have the dramatic effect on the location of the transition state along the end-to-end distance reaction coordinate, but the multidomain construction leaves the transition state almost unchanged. We have found that the maximum force in the force-extension profile from constant velocity force pulling simulations depends on temperature nonlinearly. However, for some narrow temperature interval this dependence becomes linear, as have been observed in recent experiments.
Hearing rehabilitation in Treacher Collins Syndrome with bone anchored hearing aid
Polanski, José Fernando; Plawiak, Anna Clara; Ribas, Angela
2015-01-01
Objective: To describe a case of hearing rehabilitation with bone anchored hearing aid in a patient with Treacher Collins syndrome. Case description: 3 years old patient, male, with Treacher Collins syndrome and severe complications due to the syndrome, mostly related to the upper airway and hearing. He had bilateral atresia of external auditory canals, and malformation of the pinna. The initial hearing rehabilitation was with bone vibration arch, but there was poor acceptance due the discomfort caused by skull compression. It was prescribed a model of bone-anchored hearing aid, in soft band format. The results were evaluated through behavioral hearing tests and questionnaires Meaningful Use of Speech Scale (MUSS) and Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS). Comments: The patient had a higher acceptance of the bone-anchored hearing aid compared to the traditional bone vibration arch. Audiological tests and the speech and auditory skills assessments also showed better communication and hearing outcomes. The bone-anchored hearing aid is a good option in hearing rehabilitation in this syndrome. PMID:26298651
Luckino, Frank A; Hardy, Mark A
2015-01-01
Supination external rotation ankle fractures are the most common ankle fracture subtype. Deltoid ligament injuries have often been associated with this type of injury pattern. A missed injury can lead to post-traumatic arthritis and persistent pain. The current data do not support acute deltoid rupture repair. This has been based primarily on level III and IV studies in which less than satisfactory results were reported. We believe that acute deltoid rupture repair could be indicated in select cases. We have outlined a new deltoid repair technique for use with bimalleolar, equivalent supination external rotation ankle fractures using a flexible implant and bioabsorbable anchor. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Postl, L K; Ahrens, P; Beirer, M; Crönlein, M; Imhoff, A B; Foehr, P; Burgkart, R; Braun, C; Kirchhoff, Chlodwig
2016-08-01
Osteoporosis is a highly focused issue in current scientific research and clinical treatment. Especially in rotator cuff repair, the low bone quality of patients suffering from osteoporosis is an important issue. In this context, non-biological solutions using PMMA for anchor augmentation have been developed in the recent past. The aim of this study was to evaluate whether augmentation of suture anchors using bio-absorbable osteoconductive fiber-reinforced calcium phosphate results in improved failure load of suture anchors as well. Altogether 24 suture anchors (Corkscrew FT 1 Suture Anchors, Arthrex, Naples, FL, USA) were evaluated by applying traction until pullout in 12 paired fresh frozen human cadaver humeri using a servo-hydraulic testing machine. Inclusion criteria were an age of more than 64 years, a macroscopically intact RC and an intact bone. The anchors were evaluated at the anterolateral and posteromedial aspect of the greater tuberosity. 12 suture anchors were augmented and 12 suture anchors were conventionally inserted. The failure load was significantly enhanced by 66.8 % by the augmentation method. The fiber-reinforced calcium phosphate could be easily injected and applied. The bio-absorbable cement in this study could be a promising augmentation material for RC reconstructions, but further research is necessary-the material has to be evaluated in vivo.
External post-tensioning anchorage.
DOT National Transportation Integrated Search
2011-05-01
Post-tensioning tendons in segmental bridge construction are often only anchored within the deviator and pier segments. The effectiveness of the post-tensioning (PT) system is therefore dependent on proper functioning of the anchorages. On August 28,...
[Consensus paper on the terminological differentiation of various aspect of body experience].
Röhricht, Frank; Seidler, Klaus-Peter; Joraschky, Peter; Borkenhagen, Ada; Lausberg, Hedda; Lemche, Erwin; Loew, Thomas; Porsch, Udo; Schreiber-Willnow, Karin; Tritt, Karin
2005-01-01
In the past, phenomenological research on subjective body experience was characterised by vaguely defined terminology and methodological shortcomings. The term "body image" has been applied heterogeneously in literature in order to describe a variety of bodily phenomena. In this paper, the German terminology applied to the phenomenology of body experiences is described systematically. In developing a systematic terminology the authors refer to scientific evidence as well as recent reviews, and closely adhere to definitions commonly used in English literature. Different perspectives are utilised, particularly anthropological concepts and theories from developmental and self-psychology. Distinct aspects of body experience are described within the context of a network of external determinants and along a continuum between somatic and mental anchor points. Applying the term "body experience" as umbrella term, different aspects are defined: perceptive (body schema/-perceive), affective (body-cathexis), cognitive-evaluative (body-image, body-ego) and body-consciousness. It is emphasized, that the distinct description of functional levels has to be taken as an approximation of the reality of integrated body experience.
Direct numerical simulation of the effect of an electric field on flame stability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belhi, Memdouh; Domingo, Pascale; Vervisch, Pierre
2010-12-15
The role of electric fields in stabilising combustion is a well-known phenomenon. Among the possible mechanisms favouring the anchorage of the flame base, the ion-driven wind acting directly on flow momentum ahead of the flame base could be the leading one. Direct numerical simulation has been used to verify this hypothesis and lead to a better understanding of diffusion flame base anchoring in the presence of an externally applied voltage. In this context, a simplified modelling approach is proposed to describe combustion in the presence of electric body forces. The model reproduces the tendencies of experimental observations found in themore » literature. The sensitivity of the flame lift-off height to the applied voltage is studied and the modification of the velocity field ahead of the flame base induced by the electric volume forces is highlighted. (author)« less
3D Printed Anchoring Sutures for Permanent Shaping of Tissues.
Wei, Wei; Li, Yuxiao; Yang, Huazhe; Nassab, Reza; Shahriyari, Fatemeh; Akpek, Ali; Guan, Xiaofei; Liu, Yanhui; Taranejoo, Shahrouz; Tamayol, Ali; Zhang, Yu Shrike; Khademhosseini, Ali; Jang, Hae Lin
2017-12-01
Sutures are one of the most widely used devices for adhering separated tissues after injury or surgery. However, most sutures require knotting, which can create a risk of inflammation, and can act as mechanically weak points that often result in breakage and slipping. Here, an anchoring suture is presented with a design that facilitates its propagation parallel to the suturing direction, while maximizing its resistive force against the opposite direction of external force to lock its position in tissues. Different microstructures of suture anchors are systematically designed using orthogonal arrays, and selected based on shape factors associated with mechanical strength. 3D printing is used to fabricate different types of hollow microstructured suture anchors, and optimize their structure for the effective shaping of tissues. To define the structural design for fixing tissues, the maximum force required to pull 3D printed anchors in different directions is examined with tissues. The tissue reshaping function of suture anchors is further simulated ex vivo by using swine ear, nose, and skin, and bovine muscle tendon. This study provides advantages for building functional sutures that can be used for permanently reshaping tissues with enhanced mechanical strength, eliminating the need for knotting to improve surgical efficiency. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Effects of anchoring and adjustment in the evaluation of product pricing.
Elaad, Eitan; Sayag, Neta; Ezer, Aliya
2010-08-01
Anchoring and adjustment comprise a heuristic that creates expectations. Two types of anchors were applied on participants' evaluation of products: the price reference of the product (maximum, minimum, or no price reference) and the context in which the products were evaluated (the prestige of the shopping center). Results showed that both factors anchored evaluations of products' value. Context effects were explained by the different expectations of visitors in prestigious (looking for quality) and less prestigious (seeking a bargain) centers.
NASA Astrophysics Data System (ADS)
Ames, D. P.; Osorio-Murillo, C.; Over, M. W.; Rubin, Y.
2012-12-01
The Method of Anchored Distributions (MAD) is an inverse modeling technique that is well-suited for estimation of spatially varying parameter fields using limited observations and Bayesian methods. This presentation will discuss the design, development, and testing of a free software implementation of the MAD technique using the open source DotSpatial geographic information system (GIS) framework, R statistical software, and the MODFLOW groundwater model. This new tool, dubbed MAD-GIS, is built using a modular architecture that supports the integration of external analytical tools and models for key computational processes including a forward model (e.g. MODFLOW, HYDRUS) and geostatistical analysis (e.g. R, GSLIB). The GIS-based graphical user interface provides a relatively simple way for new users of the technique to prepare the spatial domain, to identify observation and anchor points, to perform the MAD analysis using a selected forward model, and to view results. MAD-GIS uses the Managed Extensibility Framework (MEF) provided by the Microsoft .NET programming platform to support integration of different modeling and analytical tools at run-time through a custom "driver." Each driver establishes a connection with external programs through a programming interface, which provides the elements for communicating with core MAD software. This presentation gives an example of adapting the MODFLOW to serve as the external forward model in MAD-GIS for inferring the distribution functions of key MODFLOW parameters. Additional drivers for other models are being developed and it is expected that the open source nature of the project will engender the development of additional model drivers by 3rd party scientists.
ERIC Educational Resources Information Center
Bottge, Brian A.; Heinrichs, Mary; Chan, Shih-Yi; Mehta, Zara Dee; Watson, Elizabeth
2003-01-01
This study examined effects of video-based, anchored instruction and applied problems on the ability of 11 low-achieving (LA) and 26 average-achieving (AA) eighth graders to solve computation and word problems. Performance for both groups was higher during anchored instruction than during baseline, but no differences were found between instruction…
Cutolo, Maurizio; Vanhaecke, Amber; Ruaro, Barbara; Deschepper, Ellen; Ickinger, Claudia; Melsens, Karin; Piette, Yves; Trombetta, Amelia Chiara; De Keyser, Filip; Smith, Vanessa
2018-06-06
A reliable tool to evaluate flow is paramount in systemic sclerosis (SSc). We describe herein on the one hand a systematic literature review on the reliability of laser speckle contrast analysis (LASCA) to measure the peripheral blood perfusion (PBP) in SSc and perform an additional pilot study, investigating the intra- and inter-rater reliability of LASCA. A systematic search was performed in 3 electronic databases, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. In the pilot study, 30 SSc patients and 30 healthy subjects (HS) underwent LASCA assessment. Intra-rater reliability was assessed by having a first anchor rater performing the measurements at 2 time-points and inter-rater reliability by having the anchor rater and a team of second raters performing the measurements in 15 SSc and 30 HS. The measurements were repeated with a second anchor rater in the other 15 SSc patients, as external validation. Only 1 of the 14 records of interest identified through the systematic search was included in the final analysis. In the additional pilot study: intra-class correlation coefficient (ICC) for intra-rater reliability of the first anchor rater was 0.95 in SSc and 0.93 in HS, the ICC for inter-rater reliability was 0.97 in SSc and 0.93 in HS. Intra- and inter-rater reliability of the second anchor rater was 0.78 and 0.87. The identified literature regarding the reliability of LASCA measurements reports good to excellent inter-rater agreement. This very pilot study could confirm the reliability of LASCA measurements with good to excellent inter-rater agreement and found additionally good to excellent intra-rater reliability. Furthermore, similar results were found in the external validation. Copyright © 2018. Published by Elsevier B.V.
Buch, Martin Sandberg; Edwards, Adrian; Eriksson, Tina
2009-01-01
The Maturity Matrix is a group-based formative self-evaluation tool aimed at assessing the degree of organisational development in general practice and providing a starting point for local quality improvement. Earlier studies of the Maturity Matrix have shown that participants find the method a useful way of assessing their practice's organisational development. However, little is known about participants' views on the resulting efforts to implement intended changes. To explore users' perspectives on the Maturity Matrix method, the facilitation process, and drivers and barriers for implementation of intended changes. Observation of two facilitated practice meetings, 17 semi-structured interviews with participating general practitioners (GPs) or their staff, and mapping of reasons for continuing or quitting the project. General practices in Denmark Main outcomes: Successful change was associated with: a clearly identified anchor person within the practice, a shared and regular meeting structure, and an external facilitator who provides support and counselling during the implementation process. Failure to implement change was associated with: a high patient-related workload, staff or GP turnover (that seemed to affect small practices more), no clearly identified anchor person or anchor persons who did not do anything, no continuous support from an external facilitator, and no formal commitment to working with agreed changes. Future attempts to improve the impact of the Maturity Matrix, and similar tools for quality improvement, could include: (a) attention to matters of variation caused by practice size, (b) systematic counselling on barriers to implementation and support to structure the change processes, (c) a commitment from participants that goes beyond participation in two-yearly assessments, and (d) an anchor person for each identified goal who takes on the responsibility for improvement in practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rofouie, P.; Rey, A. D., E-mail: alejandro.rey@mail.mcgill.ca; Pasini, D.
Periodic surface nano-wrinkling is found throughout biological liquid crystalline materials, such as collagen films, spider silk gland ducts, exoskeleton of beetles, and flower petals. These surface ultrastructures are responsible for structural colors observed in some beetles and plants that can dynamically respond to external conditions, such as humidity and temperature. In this paper, the formation of the surface undulations is investigated through the interaction of anisotropic interfacial tension, swelling through hydration, and capillarity at free surfaces. Focusing on the cellulosic cholesteric liquid crystal (CCLC) material model, the generalized shape equation for anisotropic interfaces using the Cahn-Hoffman capillarity vector and themore » Rapini-Papoular anchoring energy are applied to analyze periodic nano-wrinkling in plant-based plywood free surfaces with water-induced cholesteric pitch gradients. Scaling is used to derive the explicit relations between the undulations’ amplitude expressed as a function of the anchoring strength and the spatially varying pitch. The optical responses of the periodic nano-structured surfaces are studied through finite difference time domain simulations indicating that CCLC surfaces with spatially varying pitch reflect light in a wavelength higher than that of a CCLC’s surface with constant pitch. This structural color change is controlled by the pitch gradient through hydration. All these findings provide a foundation to understand structural color phenomena in nature and for the design of optical sensor devices.« less
Lawrence, Daniel; Davies, Tracey-Lee; Bagshaw, Ruth; Hewlett, Paul; Taylor, Pamela; Watt, Andrew
2018-02-01
Aims and method Structured clinical judgement tools provide scope for the standardisation of forensic service gatekeeping and also allow identification of heuristics in this decision process. The DUNDRUM-1 triage tool was completed retrospectively for 121 first-time referrals to forensic services in South Wales. Fifty were admitted to medium security, 49 to low security and 22 remained in open conditions. DUNDRUM-1 total scores differed appropriately between different levels of security. However, regression revealed heuristic anchoring on the 'legal process' and 'immediacy of risk due to mental disorder' items. Clinical implications Patient placement was broadly aligned with DUNDRUM-1 recommendations. However, not all triage items informed gatekeeping decisions. It remains to be seen whether decisions anchored in this way are effective. Declaration of interest Dr Mark Freestone gave permission for AUC values from Freestone et al. (2015) to be presented here for comparison.
Weiss, William M; Saucedo, Ramon P; Robinson, John D; Lo, Chung-Chieh Jason; Morris, Randal P; Panchbhavi, Vinod K
2017-10-01
Refractory cases of Achilles tendinopathy amenable to surgery may include reattachment of the tendon using suture anchors. However, there is paucity of information describing the optimal insertion angle to maximize the tendon footprint and anchor stability in the calcaneus. The purpose of this investigation is to compare the fixation strength of suture anchors inserted at 90° and 45° (the Deadman's angle) relative to the primary compressive trabeculae of the calcaneus. A total of 12 matched pairs of adult cadaveric calcanei were excised and potted to approximate their alignment in vivo. Each pair was implanted with 5.5-mm bioabsorbable suture anchors placed either perpendicular (90°) or oblique (45°) to the primary compressive trabeculae. A tensile load was applied until failure of anchor fixation. Differences in failure load and stiffness between anchor fixation angles were determined by paired t-tests. No significant differences were detected between perpendicular and oblique suture anchor insertion relative to primary compressive trabeculae in terms of load to failure or stiffness. This investigation suggests that the fixation strength of suture anchors inserted perpendicular to the primary compression trabeculae and at the Deadman's angle are possibly comparable. Biomechanical comparison study.
Treatment of photoaged skin with topical tretinoin increases epidermal-dermal anchoring fibrils
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodley, D.T.; Briggaman, R.A.; Zelickson, A.S.
Topical 0.1% tretinoin or vehicle control was applied daily to the forearm skin of six caucasian adults for 4 months. Two-millimeter punch biopsy specimens were obtained from treatment sites at the beginning and end of the study period for electron microscopy. Anchoring fibrils within the epidermal-dermal junction of skin treatment sites were quantitated by blinded, standardized, computer-assisted morphometry. After 4 months of continual daily treatment, skin sites that received topical tretinoin showed double the anchoring fibril density compared with vehicle control sites. The possible mechanism by which topical tretinoin increases anchoring fibrils in skin include the drug's property of inhibitingmore » collagenase, a dermal enzyme that degrades anchoring fibril collagen. The authors speculate that increased numbers of collagenous anchoring fibrils within the papillary dermis of human skin is one of the connective-tissue correlates of the clinical improvement observed in photoaged skin after treatment with topical tretinoin.« less
Approaches for estimating minimal clinically important differences in systemic lupus erythematosus.
Rai, Sharan K; Yazdany, Jinoos; Fortin, Paul R; Aviña-Zubieta, J Antonio
2015-06-03
A minimal clinically important difference (MCID) is an important concept used to determine whether a medical intervention improves perceived outcomes in patients. Prior to the introduction of the concept in 1989, studies focused primarily on statistical significance. As most recent clinical trials in systemic lupus erythematosus (SLE) have failed to show significant effects, determining a clinically relevant threshold for outcome scores (that is, the MCID) of existing instruments may be critical for conducting and interpreting meaningful clinical trials as well as for facilitating the establishment of treatment recommendations for patients. To that effect, methods to determine the MCID can be divided into two well-defined categories: distribution-based and anchor-based approaches. Distribution-based approaches are based on statistical characteristics of the obtained samples. There are various methods within the distribution-based approach, including the standard error of measurement, the standard deviation, the effect size, the minimal detectable change, the reliable change index, and the standardized response mean. Anchor-based approaches compare the change in a patient-reported outcome to a second, external measure of change (that is, one that is more clearly understood, such as a global assessment), which serves as the anchor. Finally, the Delphi technique can be applied as an adjunct to defining a clinically important difference. Despite an abundance of methods reported in the literature, little work in MCID estimation has been done in the context of SLE. As the MCID can help determine the effect of a given therapy on a patient and add meaning to statistical inferences made in clinical research, we believe there ought to be renewed focus on this area. Here, we provide an update on the use of MCIDs in clinical research, review some of the work done in this area in SLE, and propose an agenda for future research.
ERIC Educational Resources Information Center
Moller, V.; Theuns, P.
2013-01-01
Bernheim's ACSA, a less conventional measure of subjective well-being originally developed for use in a clinical setting, was applied to a sample of black South African township dwellers (n = 1,020) in the Eastern Cape Province. The Anamnestic Comparative Self Assessment is an experiential self-anchoring scale with concrete anchors (Bernheim in…
2018-01-01
Yeast wall protein 1 (Ywp1) is an abundant glycoprotein of the cell wall of the yeast form of Candida albicans, the most prevalent fungal pathogen of humans. Antibodies that bind to the polypeptide backbone of isolated Ywp1 show little binding to intact yeast cells, presumably because the Ywp1 epitopes are masked by the polysaccharides of the mannoproteins that form the outer layer of the cell wall. Rare cells do exhibit much greater anti-Ywp1 binding, however, and one of these was isolated and characterized. No differences were seen in its Ywp1, but it exhibited greater adhesiveness, sensitivity to wall perturbing agents, and exposure of its underlying β-1,3-glucan layer to external antibodies. The molecular basis for this greater epitope accessibility has not been determined, but has facilitated exploration of how these properties change as a function of cell growth and morphology. In addition, previously engineered strains with reduced quantities of Ywp1 in their cell walls were also found to have greater β-1,3-glucan exposure, indicating that Ywp1 itself contributes to the masking of wall epitopes, which may be important for understanding the anti-adhesive effect of Ywp1. Ectopic production of Ywp1 by hyphae, which reduces the adhesivity of these filamentous forms of C. albicans, was similarly found to reduce exposure of the β-1,3-glucan in their walls. To monitor Ywp1 in the cell wall irrespective of its accessibility, green fluorescent protein (Gfp) was genetically inserted into wall-anchored Ywp1 using a bifunctional cassette that also allowed production from a single transfection of a soluble, anchor-free version. The wall-anchored Ywp1-Gfp-Ywp1 accumulated in the wall of the yeast forms but not hyphae, and appeared to have properties similar to native Ywp1, including its adhesion-inhibiting effect. Some pseudohyphal walls also detectably accumulated this probe. Strains of C. albicans with tandem hemagglutinin (HA) epitopes inserted into wall-anchored Ywp1 were previously created by others, and were further explored here. As above, rare cells with much greater accessibility of the HA epitopes were isolated, and also found to exhibit greater exposure of Ywp1 and β-1,3-glucan. The placement of the HA cassette inhibited the normal N-glycosylation and propeptide cleavage of Ywp1, but the wall-anchored Ywp1-HA-Ywp1 still accumulated in the cell wall of yeast forms. Bifunctional transformation cassettes were used to additionally tag these molecules with Gfp, generating soluble Ywp1-HA-Gfp and wall-anchored Ywp1-HA-Gfp-Ywp1 molecules. The former revealed unexpected electrophoretic properties caused by the HA insertion, while the latter further highlighted differences between the presence of a tagged Ywp1 molecule (as revealed by Gfp fluorescence) and its accessibility in the cell wall to externally applied antibodies specific for HA, Gfp and Ywp1, with accessibility being greatest in the rapidly expanding walls of budding daughter cells. These strains and results increase our understanding of cell wall properties and how C. albicans masks itself from recognition by the human immune system. PMID:29329339
Granger, Bruce L
2018-01-01
Yeast wall protein 1 (Ywp1) is an abundant glycoprotein of the cell wall of the yeast form of Candida albicans, the most prevalent fungal pathogen of humans. Antibodies that bind to the polypeptide backbone of isolated Ywp1 show little binding to intact yeast cells, presumably because the Ywp1 epitopes are masked by the polysaccharides of the mannoproteins that form the outer layer of the cell wall. Rare cells do exhibit much greater anti-Ywp1 binding, however, and one of these was isolated and characterized. No differences were seen in its Ywp1, but it exhibited greater adhesiveness, sensitivity to wall perturbing agents, and exposure of its underlying β-1,3-glucan layer to external antibodies. The molecular basis for this greater epitope accessibility has not been determined, but has facilitated exploration of how these properties change as a function of cell growth and morphology. In addition, previously engineered strains with reduced quantities of Ywp1 in their cell walls were also found to have greater β-1,3-glucan exposure, indicating that Ywp1 itself contributes to the masking of wall epitopes, which may be important for understanding the anti-adhesive effect of Ywp1. Ectopic production of Ywp1 by hyphae, which reduces the adhesivity of these filamentous forms of C. albicans, was similarly found to reduce exposure of the β-1,3-glucan in their walls. To monitor Ywp1 in the cell wall irrespective of its accessibility, green fluorescent protein (Gfp) was genetically inserted into wall-anchored Ywp1 using a bifunctional cassette that also allowed production from a single transfection of a soluble, anchor-free version. The wall-anchored Ywp1-Gfp-Ywp1 accumulated in the wall of the yeast forms but not hyphae, and appeared to have properties similar to native Ywp1, including its adhesion-inhibiting effect. Some pseudohyphal walls also detectably accumulated this probe. Strains of C. albicans with tandem hemagglutinin (HA) epitopes inserted into wall-anchored Ywp1 were previously created by others, and were further explored here. As above, rare cells with much greater accessibility of the HA epitopes were isolated, and also found to exhibit greater exposure of Ywp1 and β-1,3-glucan. The placement of the HA cassette inhibited the normal N-glycosylation and propeptide cleavage of Ywp1, but the wall-anchored Ywp1-HA-Ywp1 still accumulated in the cell wall of yeast forms. Bifunctional transformation cassettes were used to additionally tag these molecules with Gfp, generating soluble Ywp1-HA-Gfp and wall-anchored Ywp1-HA-Gfp-Ywp1 molecules. The former revealed unexpected electrophoretic properties caused by the HA insertion, while the latter further highlighted differences between the presence of a tagged Ywp1 molecule (as revealed by Gfp fluorescence) and its accessibility in the cell wall to externally applied antibodies specific for HA, Gfp and Ywp1, with accessibility being greatest in the rapidly expanding walls of budding daughter cells. These strains and results increase our understanding of cell wall properties and how C. albicans masks itself from recognition by the human immune system.
End-anchored polymers in good solvents from the single chain limit to high anchoring densities.
Whitmore, Mark D; Grest, Gary S; Douglas, Jack F; Kent, Michael S; Suo, Tongchuan
2016-11-07
An increasing number of applications utilize grafted polymer layers to alter the interfacial properties of solid substrates, motivating refinement in our theoretical understanding of such layers. To assess existing theoretical models of them, we have investigated end-anchored polymer layers over a wide range of grafting densities, σ, ranging from a single chain to high anchoring density limits, chain lengths ranging over two orders of magnitude, for very good and marginally good solvent conditions. We compare Monte Carlo and molecular dynamics simulations, numerical self-consistent field calculations, and experimental measurements of the average layer thickness, h, with renormalization group theory, the Alexander-de Gennes mushroom theory, and the classical brush theory. Our simulations clearly indicate that appreciable inter-chain interactions exist at all simulated areal anchoring densities so that there is no mushroom regime in which the layer thickness is independent of σ. Moreover, we find that there is no high coverage regime in which h follows the predicted scaling, h ∼ Nσ 1/3 , for classical polymer brushes either. Given that no completely adequate analytic theory seems to exist that spans wide ranges of N and σ, we applied scaling arguments for h as a function of a suitably defined reduced anchoring density, defined in terms of the solution radius of gyration of the polymer chains and N. We find that such a scaling approach enables a smooth, unified description of h in very good solvents over the full range of anchoring density and chain lengths, although this type of data reduction does not apply to marginal solvent quality conditions.
A biomechanical analysis of a single-row suture anchor fixation of a large bony bankart lesion.
Dyskin, Evgeny; Marzo, John M; Howard, Craig; Ehrensberger, Mark
2014-12-01
This study was conducted to assess whether a single-row suture anchor repair of a bony Bankart lesion comprising 19% of the glenoid length restores peak translational force and glenoid depth compared with the intact shoulder. Nine thawed adult cadaveric shoulders were dissected and mounted in 45° of abduction and 30° of external rotation. A bony Bankart lesion was simulated with an anterior longitudinal osteotomy, parallel to the superoinferior axis of the glenoid, equivalent to 19% of the glenoid length. The humeral head was displaced 10 mm anteriorly at a speed of 2 mm/s with a 50-N compressive load applied. Testing was performed with the glenoid intact, a simulated lesion, and the lesion repaired with 3 single-row suture anchors. Median (interquartile range [IQR]) peak translational force and glenoid depth were reported. The Friedman test and post hoc comparisons with the Wilcoxon signed rank test were used for between-group analyses. Peak translational force decreased after osteotomy (13.7 N; IQR, 9.6 to 15.5 N; P = .01) and increased after the repair (18.3 N; IQR, 18.3 to 20.6 N; P = .01) compared with the intact shoulder (23.7 N; IQR, 16.4 to 29.9 N). Glenoid depth significantly decreased after the osteotomy (0.2 mm; IQR, -0.6 to 0.7 mm) compared with baseline (1.7 mm; IQR, 1.3 to 2.0 mm; P = .01) and increased after repair (0.8 mm; IQR, 0.1 to 1.0 mm; P = .03) compared with the osteotomized shoulder. The glenoid depth of the repair was less than the baseline value (P = .01). Repair of an anterior bony Bankart lesion equivalent to 19% of the glenoid length with 3 suture anchors restored the peak translational force needed to anteriorly displace the humerus relative to the glenoid; however, this technique failed to restore the natural glenoid depth in a laboratory setting. Our findings describe the inability of a single-row suture anchor repair to provide anatomic fixation of the bony Bankart lesion equivalent to 19% of the glenoid length. Published by Elsevier Inc.
Localized Ignition And Subsequent Flame Spread Over Solid Fuels In Microgravity
NASA Technical Reports Server (NTRS)
Kashiwagi, T.; Nakamura, Y.; Prasad, K.; Baum, H.; Olson, S.; Fujita, O.; Nishizawa, K.; Ito, K.
2003-01-01
Localized ignition is initiated by an external radiant source at the middle of a thin solid sheet under external slow flow, simulating fire initiation in a spacecraft with a slow ventilation flow. Ignition behavior, subsequent transition simultaneously to upstream and downstream flame spread, and flame growth behavior are studied theoretically and experimentally. There are two transition stages in this study; one is the first transition from the onset of the ignition to form an initial anchored flame close to the sample surface, near the ignited area. The second transition is the flame growth stage from the anchored flame to a steady fire spread state (i.e. no change in flame size or in heat release rate) or a quasi-steady state, if either exists. Observations of experimental spot ignition characteristics and of the second transition over a thermally thin paper were made to determine the effects of external flow velocity. Both transitions have been studied theoretically to determine the effects of the confinement by a relatively small test chamber, of the ignition configuration (ignition across the sample width vs spot ignition), and of the external flow velocity on the two transitions over a thermally thin paper. This study is currently extending to two new areas; one is to include a thermoplastic sample such poly(methymethacrylate), PMMA, and the other is to determine the effects of sample thickness on the transitions. The recent results of these new studies on the first transition are briefly reported.
Implantation reduces the negative effects of bio-logging devices on birds.
White, Craig R; Cassey, Phillip; Schimpf, Natalie G; Halsey, Lewis G; Green, Jonathan A; Portugal, Steven J
2013-02-15
Animal-borne logging or telemetry devices are widely used for measurements of physiological and movement data from free-living animals. For such measurements to be relevant, however, it is essential that the devices themselves do not affect the data of interest. A recent meta-analysis reported an overall negative effect of these devices on the birds that bear them, i.e. on nesting productivity, clutch size, nest initiation date, offspring quality, body condition, flying ability, foraging behaviours, energy expenditure and survival rate. Method of attachment (harness, collar, glue, anchor, implant, breast-mounted or tailmount) had no influence on the strength of these effects but anchored and implanted transmitters had the highest reported rates of device-induced mortality. Furthermore, external devices, but not internal devices, caused an increase in 'device-induced behaviour' (comfort behaviours such as preening, fluffing and stretching, and unrest activities including unquantifiable 'active' behaviours). These findings suggest that, with the exception of device-induced behaviour, external attachment is preferable to implantation. In the present study we undertake a meta-analysis of 183 estimates of device impact from 39 studies of 36 species of bird designed to explicitly compare the effects of externally attached and surgically implanted devices on a range of traits, including condition, energy expenditure and reproduction. In contrast to a previous study, we demonstrate that externally attached devices have a consistent detrimental effect (i.e. negative influences on body condition, reproduction, metabolism and survival), whereas implanted devices have no consistent effect. We also show that the magnitude of the negative effect of externally attached devices decreases with time. We therefore conclude that device implantation is preferable to external attachment, providing that the risk of mortality associated with the anaesthesia and surgery required for implantation can be mitigated. We recommend that studies employing external devices use devices that can be borne for long periods, and, wherever possible, deploy devices in advance of the time period of interest.
Immobilization of mesoporous silica particles on stainless steel plates
NASA Astrophysics Data System (ADS)
Pasqua, Luigi; Morra, Marco
2017-03-01
A preliminary study aimed to the nano-engineering of stainless steel surface is presented. Aminopropyl-functionalized mesoporous silica is covalently and electrostatically anchored on the surface of stainless steel plates. The anchoring is carried out through the use of a nanometric spacer, and two different spacers are proposed (both below 2 nm in size). The first sample is obtained by anchoring to the stainless steel amino functionalized, a glutaryl dichloride spacer. This specie forms an amide linkage with the amino group while the unreacted acyl groups undergo hydrolysis giving a free carboxylic group. The so-obtained functionalized stainless steel plate is used as substrate for anchoring derivatized mesoporous silica particles. The second sample is prepared using 2-bromo-methyl propionic acid as spacer (BMPA). Successively, the carboxylic group of propionic acid is condensed to the aminopropyl derivatization on the external surface of the mesoporous silica particle through covalent bond. In both cases, a continuous deposition (coating thickness is around 10 μm) is obtained, in fact, XPS data do not reveal the metal elements constituting the plate. The nano-engineering of metal surfaces can represent an intriguing opportunity for producing long-term drug release or biomimetic surface.
Chen, Shi-yi; Malcarney, Hilary L; Murrell, George A C
2009-02-01
To evaluate results of margin convergence versus suture anchors in rotator cuff repair, and to determine which method is mechanically superior. Eighteen kangaroo shoulders were randomly divided into three groups (n = 6). A full thickness tendon defect 1.0 cm × 1.5 cm in size was created in the supraspinatus tendon at humeral insertion, simulating a massive rotator cuff tear. Three different techniques were employed for rotator cuff repair: (i) Mitek GII suture anchor alone (Group 1); (ii) margin convergence alone (Group 2); and (iii) margin convergence plus Mitek GII suture anchor (Group 3). Combined loads were applied to each specimen. After completion of cyclic loading, the construct was loaded to failure. ANOVA and LSD (Least Significant Difference) multiple comparisons of the means were applied to results. Cyclic load testing showed progressive gap formation in each repaired specimen with increasing cycles. Group 1 reached 50% failure at an average of 34 cycles, Group 2 at 75 cycles and Group 3 at 73 cycles. There were significant difference between Groups 1 and 2, and Groups 1 and 3 (P ≤ 0.001). After 100 loading cycles, the average gap size was 6.8 mm, 6.1 mm and 4.7 mm in Groups 1, 2 and 3, respectively. There was a significant difference between Groups 1 and 3 (P ≤ 0.015). All specimens eventually reached failure. Rotator cuff repairs with margin convergence +/- suture anchor were far stronger than suture anchor alone, both in gap formation and ultimate failure load. However, progressive gap formation with cyclic loading seems inevitable after cuff repair, which may facilitate clinical understanding of the phenomena of re-tear or residual defect. © 2009 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.
Cheng, Yanping; Yi, Geng-Hua; Annest, Lon S; Van Bladel, Kevin; Brown, Ryan; Wechsler, Andrew; Shibuya, Masahiko; Conditt, Gerard B; Peppas, Athanasios; Kaluza, Greg L; Granada, Juan F
2015-04-01
To test the feasibility of a thoracoscopically assisted, off-pump, transcatheter ventricular reconstruction (TCVR) approach in an ovine model of left ventricular (LV) anteroapical aneurysm. Myocardial infarction (MI) was induced by coil occlusion of the middle left anterior descending artery and diagonals. Two months after MI creation, TCVR was performed via a minimal thoracotomy in eight sheep. Under endoscopic and fluoroscopic guidance, trans-interventricular septal puncture was performed from the LV epicardial scar. A guidewire was externalised via a snare placed in the right ventricle from the external jugular vein. An internal anchor was inserted over the wire and positioned on the right ventricular septum and an external anchor was deployed on the LV anterior epicardium. Serial pairs of anchors were placed and plicated together to exclude the scar completely. Immediately after TCVR, echocardiography showed LV end-systolic volume decreased from pre-procedure 58.8±16.6 ml to 25.1±7.6 ml (p<0.01) and the ejection fraction increased from 32.0±7.3% to 52.0±7.5% (p<0.01). LV twist significantly improved (3.83±2.21 vs. pre-procedure -0.41±0.94, p=0.01) and the global peak-systolic longitudinal strain increased from -5.64% to -10.77% (p<0.05). TCVR using minimally invasive access techniques on the off-pump beating heart is feasible and resulted in significant improvement in LV performance.
Electro-osmosis of nematic liquid crystals under weak anchoring and second-order surface effects
NASA Astrophysics Data System (ADS)
Poddar, Antarip; Dhar, Jayabrata; Chakraborty, Suman
2017-07-01
Advent of nematic liquid crystal flows has attracted renewed attention in view of microfluidic transport phenomena. Among various transport processes, electro-osmosis stands as one of the efficient flow actuation mechanisms through narrow confinements. In the present study, we explore the electrically actuated flow of an ordered nematic fluid with ionic inclusions, taking into account the influences from surface-induced elasticity and electrical double layer (EDL) phenomena. Toward this, we devise the coupled flow governing equations from fundamental free-energy analysis, considering the contributions from first- and second-order elastic, dielectric, flexoelectric, charged surface polarization, ionic and entropic energies. The present study focuses on the influence of surface charge and elasticity effects in the resulting linear electro-osmosis through a slit-type microchannel whose surfaces are chemically treated to display a homeotropic-type weak anchoring state. An optical periodic stripe configuration of the nematic director has been observed, especially for higher electric fields, wherein the Ericksen number for the dynamic study is restricted to the order of unity. Contrary to the isotropic electrolytes, the EDL potential in this case was found to be dependent on the external field strength. Through a systematic investigation, we brought out the fact that the wavelength of the oscillating patterns is dictated mainly by the external field, while the amplitude depends on most of the physical variables ranging from the anchoring strength and the flexoelectric coefficients to the surface charge density and electrical double layer thickness.
49 CFR 178.338-13 - Supporting and anchoring.
Code of Federal Regulations, 2010 CFR
2010-10-01
... whole or in part the structural member used in place of a motor vehicle frame, the cargo tank or the... vehicle frame, the tank or jacket must be supported by external cradles, load rings, or longitudinal... subchapter), multiplied by the following factors. The effects of fatigue must also be considered in the...
Spherical Particle in Nematic Liquid Crystal Under an External Field: The Saturn Ring Regime
NASA Astrophysics Data System (ADS)
Alama, Stan; Bronsard, Lia; Lamy, Xavier
2018-03-01
We consider a nematic liquid crystal occupying the exterior region in R^3 outside of a spherical particle, with radial strong anchoring. Within the context of the Landau-de Gennes theory, we study minimizers subject to an external field, modeled by an additional term which favors nematic alignment parallel to the field. When the external field is high enough, we obtain a scaling law for the energy. The energy scale corresponds to minimizers concentrating their energy in a boundary layer around the particle, with quadrupolar symmetry. This suggests the presence of a Saturn ring defect around the particle, rather than a dipolar director field typical of a point defect.
Magneto-optic dynamics in a ferromagnetic nematic liquid crystal
NASA Astrophysics Data System (ADS)
Potisk, Tilen; Mertelj, Alenka; Sebastián, Nerea; Osterman, Natan; Lisjak, Darja; Brand, Helmut R.; Pleiner, Harald; Svenšek, Daniel
2018-01-01
We investigate dynamic magneto-optic effects in a ferromagnetic nematic liquid crystal experimentally and theoretically. Experimentally we measure the magnetization and the phase difference of the transmitted light when an external magnetic field is applied. As a model we study the coupled dynamics of the magnetization, M , and the director field, n , associated with the liquid crystalline orientational order. We demonstrate that the experimentally studied macroscopic dynamic behavior reveals the importance of a dynamic cross-coupling between M and n . The experimental data are used to extract the value of the dissipative cross-coupling coefficient. We also make concrete predictions about how reversible cross-coupling terms between the magnetization and the director could be detected experimentally by measurements of the transmitted light intensity as well as by analyzing the azimuthal angle of the magnetization and the director out of the plane spanned by the anchoring axis and the external magnetic field. We derive the eigenmodes of the coupled system and study their relaxation rates. We show that in the usual experimental setup used for measuring the relaxation rates of the splay-bend or twist-bend eigenmodes of a nematic liquid crystal one expects for a ferromagnetic nematic liquid crystal a mixture of at least two eigenmodes.
Tunable nano-wrinkling of chiral surfaces: Structure and diffraction optics
NASA Astrophysics Data System (ADS)
Rofouie, P.; Pasini, D.; Rey, A. D.
2015-09-01
Periodic surface nano-wrinkling is found throughout biological liquid crystalline materials, such as collagen films, spider silk gland ducts, exoskeleton of beetles, and flower petals. These surface ultrastructures are responsible for structural colors observed in some beetles and plants that can dynamically respond to external conditions, such as humidity and temperature. In this paper, the formation of the surface undulations is investigated through the interaction of anisotropic interfacial tension, swelling through hydration, and capillarity at free surfaces. Focusing on the cellulosic cholesteric liquid crystal (CCLC) material model, the generalized shape equation for anisotropic interfaces using the Cahn-Hoffman capillarity vector and the Rapini-Papoular anchoring energy are applied to analyze periodic nano-wrinkling in plant-based plywood free surfaces with water-induced cholesteric pitch gradients. Scaling is used to derive the explicit relations between the undulations' amplitude expressed as a function of the anchoring strength and the spatially varying pitch. The optical responses of the periodic nano-structured surfaces are studied through finite difference time domain simulations indicating that CCLC surfaces with spatially varying pitch reflect light in a wavelength higher than that of a CCLC's surface with constant pitch. This structural color change is controlled by the pitch gradient through hydration. All these findings provide a foundation to understand structural color phenomena in nature and for the design of optical sensor devices.
The anchoring bias reflects rational use of cognitive resources.
Lieder, Falk; Griffiths, Thomas L; M Huys, Quentin J; Goodman, Noah D
2018-02-01
Cognitive biases, such as the anchoring bias, pose a serious challenge to rational accounts of human cognition. We investigate whether rational theories can meet this challenge by taking into account the mind's bounded cognitive resources. We asked what reasoning under uncertainty would look like if people made rational use of their finite time and limited cognitive resources. To answer this question, we applied a mathematical theory of bounded rationality to the problem of numerical estimation. Our analysis led to a rational process model that can be interpreted in terms of anchoring-and-adjustment. This model provided a unifying explanation for ten anchoring phenomena including the differential effect of accuracy motivation on the bias towards provided versus self-generated anchors. Our results illustrate the potential of resource-rational analysis to provide formal theories that can unify a wide range of empirical results and reconcile the impressive capacities of the human mind with its apparently irrational cognitive biases.
Comparison of Suture-Based Anchors and Traditional Bioabsorbable Anchors in Foot and Ankle Surgery.
Hembree, W Chad; Tsai, Michael A; Parks, Brent G; Miller, Stuart D
We compared the pullout strength of a suture-based anchor versus a bioabsorbable anchor in the distal fibula and calcaneus and evaluated the relationship between bone mineral density and peak load to failure. Eight paired cadaveric specimens underwent a modified Broström procedure and Achilles tendon reattachment. The fibula and calcaneus in the paired specimens received either a suture-based anchor or a bioabsorbable suture anchor. The fibular and calcaneal specimens were loaded to failure, defined as a substantial decrease in the applied load or pullout from the bone. In the fibula, the peak load to failure was significantly greater with the suture-based versus the bioabsorbable anchors (133.3 ± 41.8 N versus 76.8 ± 35.3 N; p = .002). No significant difference in load with 5 mm of displacement was found between the 2 groups. In the calcaneus, no difference in the peak load to failure was found between the 2 groups, and the peak load to failure with 5 mm of displacement was significantly lower with the suture-based than with the bioabsorbable anchors (52.2 ± 9.8 N versus 75.9 ± 12.4 N; p = .003). Bone mineral density and peak load to failure were significantly correlated in the fibula with the suture-based anchor. An innovative suture-based anchor had a greater peak load to failure compared with a bioabsorbable anchor in the fibula. In the calcaneus, the load at 5 mm of displacement was significantly lower in the suture-based than in the bioabsorbable group. The correlation findings might indicate the need for a cortical bone shelf with the suture-based anchor. Suture-based anchors could be a viable alternative to bioabsorbable anchors for certain foot and ankle procedures. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Design and Application of a Field Sensing System for Ground Anchors in Slopes
Choi, Se Woon; Lee, Jihoon; Kim, Jong Moon; Park, Hyo Seon
2013-01-01
In a ground anchor system, cables or tendons connected to a bearing plate are used for stabilization of slopes. Then, the stability of a slope is dependent on maintaining the tension levels in the cables. So far, no research on a strain-based field sensing system for ground anchors has been reported. Therefore, in this study, a practical monitoring system for long-term sensing of tension levels in tendons for anchor-reinforced slopes is proposed. The system for anchor-reinforced slopes is composed of: (1) load cells based on vibrating wire strain gauges (VWSGs), (2) wireless sensor nodes which receive and process the signals from load cells and then transmit the result to a master node through local area communication, (3) master nodes which transmit the data sent from sensor nodes to the server through mobile communication, and (4) a server located at the base station. The system was applied to field sensing of ground anchors in the 62 m-long and 26 m-high slope at the side of the highway. Based on the long-term monitoring, the safety of the anchor-reinforced slope can be secured by the timely applications of re-tensioning processes in tendons. PMID:23507820
Use of Continuous Exponential Families to Link Forms via Anchor Tests. Research Report. ETS RR-11-11
ERIC Educational Resources Information Center
Haberman, Shelby J.; Yan, Duanli
2011-01-01
Continuous exponential families are applied to linking test forms via an internal anchor. This application combines work on continuous exponential families for single-group designs and work on continuous exponential families for equivalent-group designs. Results are compared to those for kernel and equipercentile equating in the case of chained…
Initial experience with the Sophono Alpha 1 osseointegrated implant.
Escorihuela-García, Vicente; Llópez-Carratalá, Ignacio; Pitarch-Ribas, Ignacia; Latorre-Monteagudo, Emilia; Marco-Algarra, Jaime
2014-01-01
In the last several years, bone anchored hearing aids have proven to be useful in treating conductive and mixed unilateral or bilateral hearing loss, as well as for sensorineural unilateral hearing loss. The Sophono Alpha 1 model has the advantage of not requiring an abutment, with it being coupled by magnetism instead. We report the cases of 3 infants with congenital malformations of external and middle ear. Audiometry showed conductive hearing loss. All 3 patients were implanted with Alpha 1 model (Sophono). Patients evolved satisfactorily. After 30 days we applied the processor and the control audiometry showed a marked improvement of hearing thresholds, although without a complete closure of the gap. With minimal care, the skin over the implant remained in excellent condition, with a very satisfactory cosmetic outcome. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.
Gely, P; Drouin, G; Thiry, P S; Tremblay, G R
1984-11-01
A new composite prosthesis was recently proposed for the anterior cruciate ligament. It is implanted in the femur and the tibia through two anchoring channels. Its intra-articular portion, composed of a fiber mesh sheath wrapped around a silicone rubber cylindrical core, reproduces satisfactorily the ligament response in tension. However, the prosthesis does not only undergo elongation. In addition, it is submitted to torsion in its intra-articular portion and bending at its ends. This paper presents a new method to evaluate these two types of deformations throughout a knee flexion by means of a geometric model of the implanted prosthesis. Input data originate from two sources: (i) a three-dimensional anatomic topology of the knee joint in full extension, providing the localization of the prosthesis anchoring channels, and ii) a kinematic model of the knee describing the motion of these anchoring channels during a physiological flexion of the knee joint. The evaluation method is independent of the way input data are obtained. This method, applied to a right cadaveric knee, shows that the orientation of the anchoring channels has a large effect on the extent of torsion and bending applied to the implanted prosthesis throughout a knee flexion, especially on the femoral side. The study suggests also the best choice for the anchoring channel axes orientation.
Ikeuchi, Takuro; Agrawal, Saurabh; Ezoe, Masayuki; Mori, Shogo; Kimura, Mutsumi
2015-11-01
A series of zinc phthalocyanine sensitizers (PcS22-24) having a pyridine anchoring group are designed and synthesized to investigate the structural dependence on performance in dye-sensitized solar cells. The pyridine-anchor zinc phthalocyanine sensitizer PcS23 shows 79 % incident-photon to current-conversion efficiency (IPCE) and 6.1 % energy conversion efficiency, which are comparable with similar phthalocyanine dyes having a carboxylic acid anchoring group. Based on DFT calculations, the high IPCE is attributed with the mixture of an excited-state molecular orbital of the sensitizer and the orbitals of TiO2 . Between pyridine and carboxylic acid anchor dyes, opposite trends are observed in the linker-length dependence of the IPCE. The red-absorbing PcS23 is applied for co-sensitization with a carboxyl-anchor organic dye D131 that has a complementary spectral response. The site-selective adsorption of PcS23 and D131 on the TiO2 surface results in a panchromatic photocurrent response for the whole visible-light region of sun light. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Simulations of a Membrane-Anchored Peptide: Structure, Dynamics, and Influence on Bilayer Properties
Jensen, Morten Ø.; Mouritsen, Ole G.; Peters, Günther H.
2004-01-01
A three-dimensional structure of a model decapeptide is obtained by performing molecular dynamics simulations of the peptide in explicit water. Interactions between an N-myristoylated form of the folded peptide anchored to dipalmitoylphosphatidylcholine fluid phase lipid membranes are studied at different applied surface tensions by molecular dynamics simulations. The lipid membrane environment influences the conformational space explored by the peptide. The overall secondary structure of the anchored peptide is found to deviate at times from its structure in aqueous solution through reversible conformational transitions. The peptide is, despite the anchor, highly mobile at the membrane surface with the peptide motion along the bilayer normal being integrated into the collective modes of the membrane. Peptide anchoring moderately alters the lateral compressibility of the bilayer by changing the equilibrium area of the membrane. Although membrane anchoring moderately affects the elastic properties of the bilayer, the model peptide studied here exhibits conformational flexibility and our results therefore suggest that peptide acylation is a feasible way to reinforce peptide-membrane interactions whereby, e.g., the lifetime of receptor-ligand interactions can be prolonged. PMID:15189854
Physical Analysis Work for Slope Stability at Shah Alam, Selangor
NASA Astrophysics Data System (ADS)
Ishak, M. F.; Zaini, M. S. I.
2018-04-01
Slope stability analysis is performed to assess the equilibrium conditions and the safe design of a human-made or natural slope to find the endangered areas. Investigation of potential failure and determination of the slope sensitivity with regard to safety, reliability and economics were parts of this study. Ground anchor is designed to support a structure in this study. Ground anchor were implemented at the Mechanically Stabilized Earth (MSE) wall along Anak Persiaran Jubli Perak to overcome the further cracking of pavement parking, concrete deck and building of the Apartments. A result from the laboratory testing of soil sample such as index test and shear strength test were applied to the Slope/W software with regard to the ground anchors that were implemented. The ground anchors were implemented to increase the value of the factor of safety (FOS) of the MSE Wall. The value of the factor of safety (FOS) before implementing the ground anchor was 0.800 and after the ground anchor was implemented the value increase to 1.555. The increase percentage of factor of safety by implementing on stability of slope was 94.38%.
COMPLICATIONS RESULTING FROM THE USE OF METAL ANCHORS IN SHOULDER ARTHROSCOPY
Godinho, Glaydson Gomes; França, Flavio Oliveira; Alves Freitas, José Marcio; Aguiar, Paulo Nascimento; de Carvalho Leite, Marcelo
2015-01-01
To identify the complications concerning the use of metal anchors in shoulder arthroscopic procedures. Methods: 28 shoulders of 28 patients (23 male and 5 female) have been re-operated in the period between December 1997 and August 2007, at Hospital Ortopédico, Belo Horizonte Hospital and Military Police Hospital in Belo Horizonte, MG, as a result of complications such as loose anchors and prominent anchors. The primary surgeries intended to treat 20 anterior traumatic instabilities (71.5%), one posterior instability (3.5%), one slap injury (3.5%), six procedures for treating injuries on the rotator cuff (21.5%). We used the X-ray classification suggested by Samilson and Prieto and Outerbridge arthroscopic classification for assessing patients' degree of arthrosis. All patients were evaluated by the UCLA (University of California at Los Angeles) index criteria. Results: In all patients, arthroscopic reviews were made. In two cases, after anchors removal, clinical signs of instability were seen, leading to the decision of providing open stabilization by Latarjet-Patte technique. Conclusion: the complications with metallic-suture anchors result from inappropriate surgical techniques applied in arthroscopy. PMID:26998465
Rodríguez-González, Abril; Sarabeev, Volodimir; Balbuena, Juan Antonio
2017-01-01
The search for phylogenetic signal in morphological traits using geometric morphometrics represents a powerful approach to estimate the relative weights of convergence and shared evolutionary history in shaping organismal form. We assessed phylogenetic signal in the form of ventral and dorsal haptoral anchors of 14 species of Ligophorus occurring on grey mullets (Osteichthyes: Mugilidae) from the Mediterranean, the Black Sea and the Sea of Azov. The phylogenetic relationships among these species were mapped onto the morphospaces of shape and size of dorsal and ventral anchors and two different tests were applied to establish whether the spatial positions in the morphospace were dictated by chance. Overall significant phylogenetic signal was found in the data. Allometric effects on anchor shape were moderate or non-significant in the case of evolutionary allometry. Relatively phylogenetically distant species occurring on the same host differed markedly in anchor morphology indicating little influence of host species on anchor form. Our results suggest that common descent and shared evolutionary history play a major role in determining the shape and, to a lesser degree in the size of haptoral anchors in Ligophorus spp. The present approach allowed tracing paths of morphological evolution in anchor shape. Species with narrow anchors and long shafts were associated predominately with Liza saliens. This morphology was considered to be ancestral relative to anchors of species occurring on Liza haematocheila and M. cephalus possessing shorter shafts and longer roots. Evidence for phylogenetic signal was more compelling for the ventral anchors, than for the dorsal ones, which could reflect different functional roles in attachment to the gills. Although phylogeny and homoplasy may act differently in other monogeneans, the present study delivers a common framework to address effectively the relationships among morphology, phylogeny and other traits, such as host specificity or niche occupancy.
Design of SC walls and slabs for impulsive loading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varma, Amit H.
2015-11-11
Reinforced concrete (RC) structures have historically been the preferred choice for blast resistant structures because of their mass and the ductility provided by steel reinforcement. Steel-plate composite (SC) walls are a viable alternative to RC for protecting the infrastructure against explosive threats. SC structures consist of two steel faceplates with a plain concrete core between them. The steel faceplates are anchored to the concrete using stud anchors and connected to each other using tie bars. SC structures provide mass from the concrete infill and ductility from the continuous external steel faceplates. This dissertation presents findings and recommendations from experimental andmore » analytical investigations of the performance of SC walls subjected to far-field blast loads.« less
Cho, Jong Ho; Kim, HoJoong; Kim, Jhingook
2012-10-01
Here, we describe an external tracheal stabilization technique used in a patient with tracheomalacia. A 56-year-old man presented with tracheomalacia due to prolonged mechanical ventilation. The malacic tracheal segment was approximately 2 cm in length. The malacic segment was covered with a silicone tube sutured in place using Prolene sutures (Ethicon, Somerville, NJ). Several anchoring sutures were placed between the tracheal mucosa and the silicone tube without violating the mucosal continuity. The patient was discharged on postoperative day 5 without complication. This method of external tracheal stabilization is a less invasive alternative for the management of this particular patient. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Anchorage performance of a high-pressure pre-tightening resin anchor with a compressed grouting body
Tian, Jiansheng; Hu, Li
2017-01-01
Supports for deep mine roadways located in soft surrounding rock face several problems: difficulty in applying pre-tightening force, low bearing capacity, and poor initial support. To solve these problems, this study proposes a high-pressure pre-tightening resin anchor with a compressed grouting body for use in soft and fractured rock surrounding a deep roadway. Using model experiments, we analyzed the anchorage performance of the proposed anchor and a conventional tensile-type anchor for three different values of the elastic modulus of the surrounding rock. The results showed that regardless of the surrounding rock type, the peak micro-strain (642–541) and displacement (6.09–6.5 mm) at the pull-out end of the proposed anchor were always smaller than the peak micro-strain (1433–1105) and displacement (8.77–9.2 mm) at the pull-out end of the conventional anchor. Furthermore, as the anchor’s pre-tightening force increased from 20 kN to 120 kN, the anchor’s strain remained concentrated over a length of 0.4 m from the bearing end. Compared with conventional tensile-type anchors, the proposed high-pressure pre-tightening resin anchor with a compressed grouting body has a higher ultimate bearing capacity, allows the grouting length to be decreased to 0.4 m, and provides initial support resistance. PMID:28196084
The Effect of Anchor Test Construction on Scale Drift
ERIC Educational Resources Information Center
Antal, Judit; Melican, Gerald; Proctor, Thomas; Wiley, Andrew
2010-01-01
Presented at the Annual Meeting of National Council on Measurement in Education (NCME) in 2010. The focus of the research is to investigate the effect of applying the Sinharay & Holland (2007) midi-test idea for building anchor tests to an on-going testing program with a series of versions of the test and comparing these results to the more…
Analysis of suture anchor eyelet position on suture failure load.
Aktay, Sevima A; Kowaleski, Michael P
2011-06-01
To compare mechanical performance of 2 orientations of the 5 mm Corkscrew® suture anchor with #5 Fiberwire® . In vitro biomechanical study. Suture anchor-suture constructs (n=40). Acute and cyclic tensile loads were applied to suture threaded through eyelets of 40 anchors perpendicular to the long axis of the anchor. Eyelets were positioned so that the suture pull was in line with (anchor rotation angle of 0° [ARA 0]) or 90° (ARA 90) to the eyelet plane. Load at failure, stiffness, and cycles to failure were determined. All constructs failed by suture breakage at the eyelet. Mean load at failure was significantly higher in the ARA 90 group (634 ± 93 N) compared with the ARA 0 group (495 ± 52 N; P=.0015). No significant difference was found between groups for mean number of cycles to failure (270 ± 177 versus 178 ± 109; P=.2166) and stiffness (50 ± 4 versus 48 ± 5 N/mm; P=.3141). The Corkscrew® 5 mm suture anchor with Fiberwire® suture fails via suture breakage at the eyelet under higher acute loads if the suture is loaded at an angle of 90° compared with 0° with respect to the plane of the eyelet. © Copyright 2011 by The American College of Veterinary Surgeons.
Sherman, Seth L; Copeland, Marilyn E; Milles, Jeffrey L; Flood, David A; Pfeiffer, Ferris M
2016-06-01
To evaluate the biomechanical fixation strength of suture anchor and transosseous tunnel repair of the quadriceps tendon in a standardized cadaveric repair model. Twelve "patella-only" specimens were used. Dual-energy X-ray absorptiometry measurement was performed to ensure equal bone quality amongst groups. Specimens were randomly assigned to either a suture anchor repair of quadriceps tendon group (n = 6) or a transosseous tunnel repair group (n = 6). Suture type and repair configuration were equivalent. After the respective procedures were performed, each patella was mounted into a gripping jig. Tensile load was applied at a rate of 0.1 mm/s up to 100 N after which cyclic loading was applied at a rate of 1 Hz between magnitudes of 50 to 150 N, 50 to 200 N, 50 to 250 N, and tensile load at a rate of 0.1 mm/s until failure. Outcome measures included load to failure, displacement at 1st 100 N load, and displacement after each 10th cycle of loading. The measured cyclic displacement to the first 100 N, 50 to 150 N, 50 to 200 N, and 50 to 250 N was significantly less for suture anchors than transosseous tunnels. There was no statistically significant difference in ultimate load to failure between the 2 groups (P = .40). Failure mode for all suture anchors except one was through the soft tissue. Failure mode for all transosseous specimens but one was pulling the repair through the transosseous tunnel. Suture anchor quadriceps tendon repairs had significantly decreased gapping during cyclic loading, but no statistically significant difference in ultimate load to failure when compared with transosseous tunnel repairs. Although suture anchor quadriceps tendon repair appears to be a biomechanically superior construct, a clinical study is needed to confirm this technique as a viable alternative to gold standard transosseous techniques. Although in vivo studies are needed, these results support the suture anchor technique as a viable alternative to transosseous repair of the quadriceps tendon. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Ito, Mikako; Ohno, Kinji
2018-02-20
Endplate acetylcholinesterase (AChE) deficiency is a form of congenital myasthenic syndrome (CMS) caused by mutations in COLQ, which encodes collagen Q (ColQ). ColQ is an extracellular matrix (ECM) protein that anchors AChE to the synaptic basal lamina. Biglycan, encoded by BGN, is another ECM protein that binds to the dystrophin-associated protein complex (DAPC) on skeletal muscle, which links the actin cytoskeleton and ECM proteins to stabilize the sarcolemma during repeated muscle contractions. Upregulation of biglycan stabilizes the DPAC. Gene therapy can potentially ameliorate any disease that can be recapitulated in cultured cells. However, the difficulty of tissue-specific and developmental stage-specific regulated expression of transgenes, as well as the difficulty of introducing a transgene into all cells in a specific tissue, prevents us from successfully applying gene therapy to many human diseases. In contrast to intracellular proteins, an ECM protein is anchored to the target tissue via its specific binding affinity for protein(s) expressed on the cell surface within the target tissue. Exploiting this unique feature of ECM proteins, we developed protein-anchoring therapy in which a transgene product expressed even in remote tissues can be delivered and anchored to a target tissue using specific binding signals. We demonstrate the application of protein-anchoring therapy to two disease models. First, intravenous administration of adeno-associated virus (AAV) serotype 8-COLQ to Colq-deficient mice, resulting in specific anchoring of ectopically expressed ColQ-AChE at the NMJ, markedly improved motor functions, synaptic transmission, and the ultrastructure of the neuromuscular junction (NMJ). In the second example, Mdx mice, a model for Duchenne muscular dystrophy, were intravenously injected with AAV8-BGN. The treatment ameliorated motor deficits, mitigated muscle histopathologies, decreased plasma creatine kinase activities, and upregulated expression of utrophin and DAPC component proteins. We propose that protein-anchoring therapy could be applied to hereditary/acquired defects in ECM and secreted proteins, as well as therapeutic overexpression of such factors. Copyright © 2017 International Society of Matrix Biology. Published by Elsevier B.V. All rights reserved.
Protein-Anchoring Therapy of Biglycan for Mdx Mouse Model of Duchenne Muscular Dystrophy.
Ito, Mikako; Ehara, Yuka; Li, Jin; Inada, Kosuke; Ohno, Kinji
2017-05-01
Duchenne muscular dystrophy (DMD) is a devastating muscle disease caused by loss-of-function mutations in DMD encoding dystrophin. No rational therapy is currently available. Utrophin is a paralog of dystrophin and is highly expressed at the neuromuscular junction. In mdx mice, utrophin is naturally upregulated throughout the muscle fibers, which mitigates muscular dystrophy. Protein-anchoring therapy was previously reported, in which a recombinant extracellular matrix (ECM) protein is delivered to and anchored to a specific target using its proprietary binding domains. Being prompted by a report that intramuscular and intraperitoneal injection of an ECM protein, biglycan, upregulates expression of utrophin and ameliorates muscle pathology in mdx mice, protein-anchoring therapy was applied to mdx mice. Recombinant adeno-associated virus serotype 8 (rAAV8) carrying hBGN encoding human biglycan was intravenously injected into 5-week-old mdx mice. The rAAV8-hBGN treatment improved motor deficits and decreased plasma creatine kinase activities. In muscle sections of treated mice, the number of central myonuclei and the distribution of myofiber sizes were improved. The treated mice increased gene expressions of utrophin and β1-syntrophin, as well as protein expressions of biglycan, utrophin, γ-sarcoglycan, dystrobrevin, and α1-syntrophin. The expression of hBGN in the skeletal muscle of the treated mice was 1.34-fold higher than that of the native mouse Bgn (mBgn). The low transduction efficiency and improved motor functions suggest that biglycan expressed in a small number of muscle fibers was likely to have been secreted and anchored to the cell surface throughout the whole muscular fibers. It is proposed that the protein-anchoring strategy can be applied not only to deficiency of an ECM protein as previously reported, but also to augmentation of a naturally induced ECM protein.
The effect of the remplissage procedure on shoulder range of motion: a cadaveric study.
Omi, Rei; Hooke, Alexander W; Zhao, Kristin D; Matsuhashi, Tomoya; Goto, Akira; Yamamoto, Nobuyuki; Sperling, John W; Steinmann, Scott P; Itoi, Eiji; An, Kai-Nan
2014-02-01
The purpose of this in vitro biomechanical study was to assess the effects of the remplissage procedure for small- and large-sized Hill-Sachs lesions (HSLs) on shoulder range of motion (ROM) with a special interest in the apprehension position. HSLs of 50% and 100% of the glenoid width were simulated in 7 cadaveric shoulders as small and large lesions, respectively, and the postoperative condition was reproduced by placing suture anchors on the articular surface and tying down the infraspinatus at the medial edge of the would-be lesion site. ROMs were measured in abduction, internal rotation, and external rotation with the humerus in the adducted and abducted position. In addition, the ROM was measured in the anterior apprehension position, in which 2 torques of external rotation and extension were applied simultaneously, and external rotation and horizontal extension ROMs were measured with the humerus in different abduction angles (20°, 40°, and 60°). For standard ROMs, the procedure for the 50% HSL maintained complete ROMs, whereas the procedure for the 100% HSL significantly decreased external rotation ROM with the humerus in both the adducted and abducted positions, as well as abduction ROM. In the apprehension position, remplissage for the 50% HSL decreased extension ROM with the humerus abducted to 40° and 60°. Remplissage for the 100% HSL significantly decreased both external and extension ROMs regardless of the humeral abduction angle. In the cadaveric model with an intact humeral head and the simulated postoperative condition, the remplissage procedure for a large HSL caused significant restrictions in ROM of abduction in the scapular plane and external rotation with the humerus in both adduction and abduction. It also caused significant restrictions in both external rotation and extension ROMs in the apprehension position. The indication for the remplissage procedure for the larger HSL should be considered carefully, especially for the competitive throwing athlete who needs exceptional external rotation ROM for optimal overhead throwing performance. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
On-patient see-through augmented reality based on visual SLAM.
Mahmoud, Nader; Grasa, Óscar G; Nicolau, Stéphane A; Doignon, Christophe; Soler, Luc; Marescaux, Jacques; Montiel, J M M
2017-01-01
An augmented reality system to visualize a 3D preoperative anatomical model on intra-operative patient is proposed. The hardware requirement is commercial tablet-PC equipped with a camera. Thus, no external tracking device nor artificial landmarks on the patient are required. We resort to visual SLAM to provide markerless real-time tablet-PC camera location with respect to the patient. The preoperative model is registered with respect to the patient through 4-6 anchor points. The anchors correspond to anatomical references selected on the tablet-PC screen at the beginning of the procedure. Accurate and real-time preoperative model alignment (approximately 5-mm mean FRE and TRE) was achieved, even when anchors were not visible in the current field of view. The system has been experimentally validated on human volunteers, in vivo pigs and a phantom. The proposed system can be smoothly integrated into the surgical workflow because it: (1) operates in real time, (2) requires minimal additional hardware only a tablet-PC with camera, (3) is robust to occlusion, (4) requires minimal interaction from the medical staff.
ERIC Educational Resources Information Center
Powers, Donald; Schedl, Mary; Papageorgiou, Spiros
2017-01-01
The aim of this study was to develop, for the benefit of both test takers and test score users, enhanced "TOEFL ITP"® test score reports that go beyond the simple numerical scores that are currently reported. To do so, we applied traditional scale anchoring (proficiency scaling) to item difficulty data in order to develop performance…
Laboratory research of hydraulic fracturing with tangential loading of borehole wall
NASA Astrophysics Data System (ADS)
Kurlenya, MV; Patutin, AV; Rybalkin, LA; Serdyukov, SV; Shilova, TV
2017-02-01
Under study is transverse fracturing of an organic glass block through secondary shearing stress applied to the borehole wall. To this effect, a system composed of a press sealer and a collet anchor manufactured in two options has been designed. It is shown than an anchor with a circular groove allows reducing breakdown pressure and enables effective transverse fracture at the borehole bottom.
Rodríguez-González, Abril; Sarabeev, Volodimir; Balbuena, Juan Antonio
2017-01-01
The search for phylogenetic signal in morphological traits using geometric morphometrics represents a powerful approach to estimate the relative weights of convergence and shared evolutionary history in shaping organismal form. We assessed phylogenetic signal in the form of ventral and dorsal haptoral anchors of 14 species of Ligophorus occurring on grey mullets (Osteichthyes: Mugilidae) from the Mediterranean, the Black Sea and the Sea of Azov. The phylogenetic relationships among these species were mapped onto the morphospaces of shape and size of dorsal and ventral anchors and two different tests were applied to establish whether the spatial positions in the morphospace were dictated by chance. Overall significant phylogenetic signal was found in the data. Allometric effects on anchor shape were moderate or non-significant in the case of evolutionary allometry. Relatively phylogenetically distant species occurring on the same host differed markedly in anchor morphology indicating little influence of host species on anchor form. Our results suggest that common descent and shared evolutionary history play a major role in determining the shape and, to a lesser degree in the size of haptoral anchors in Ligophorus spp. The present approach allowed tracing paths of morphological evolution in anchor shape. Species with narrow anchors and long shafts were associated predominately with Liza saliens. This morphology was considered to be ancestral relative to anchors of species occurring on Liza haematocheila and M. cephalus possessing shorter shafts and longer roots. Evidence for phylogenetic signal was more compelling for the ventral anchors, than for the dorsal ones, which could reflect different functional roles in attachment to the gills. Although phylogeny and homoplasy may act differently in other monogeneans, the present study delivers a common framework to address effectively the relationships among morphology, phylogeny and other traits, such as host specificity or niche occupancy. PMID:28542570
Er, Mehmet Serhan; Altinel, Levent; Eroglu, Mehmet; Verim, Ozgur; Demir, Teyfik; Atmaca, Halil
2014-08-22
The purpose of the present study was to compare the results of various types of anchor applications with or without augmentation in both osteopenic and severely osteoporotic bone models. Two different types of suture anchors were tested in severely osteoporotic (SOP) and osteopenic polyurethane (PU) foam blocks using an established protocol. An Instron machine applied static loading parallel to the axis of insertion until failure, and the mean anchor failure strengths were calculated. The mode of failure (anchor pullout, suture tear) was recorded. The anchors tested included the Corkscrew (CS) (Arthrex Inc., Naples, FL, USA) (without augmentation, polymethylmethacrylate (PMMA)-augmented, and bioabsorbable tricalcium phosphate (TCP) cement-augmented) and Corkscrew FT II (CS FT II) 5.5 mm (without augmentation as used routinely). The mean failure loads for both SOP and osteopenic PU foam blocks, respectively, were as follows: CS, 16.2 and 212.4 N; CS with TCP, 75.2 and 396 N; CS with PMMA, 101.2 and 528.8 N; CS FT II, 13.8 and 339.8 N. Augmentation of CS with TCP or PMMA would be essential to SOP bones. In the osteopenic bone model, although anchor fixation augmented with PMMA is the best fixation method, CS augmented with TCP cement or CS FT II without any need for augmentation may also be used as an alternative.
Control of aqueous droplets using magnetic and electrostatic forces.
Ohashi, Tetsuo; Kuyama, Hiroki; Suzuki, Koichi; Nakamura, Shin
2008-04-07
Basic control operations were successfully performed on an aqueous droplet using both magnetic and electrostatic forces. In our droplet-based microfluidics, magnetic beads were incorporated in an aqueous droplet as a force mediator. This report describes droplet anchoring and separation of the beads from the droplet using a combination of magnetic and electrostatic forces. When an aqueous droplet is placed in an oil-filled reservoir, the droplet sinks to the bottom, under which an electrode had been placed. The droplet was adsorbed (or anchored) to the bottom surface on the electrode when a DC voltage was applied to the electrode. The magnetic beads were removed with magnetic force after the droplet had been anchored. Surfactant addition into droplet solution was very effective for the elimination of electric charge, which resulted in the stable adsorption of a droplet to hydrophobic substrate under an applied voltage of DC 0.5-3 kV. In a sequential process, small volume of aqueous liquid was successfully transferred using both magnetic and electrostatic forces.
Anchoring effect on first passage process in Taiwan financial market
NASA Astrophysics Data System (ADS)
Liu, Hsing; Liao, Chi-Yo; Ko, Jing-Yuan; Lih, Jiann-Shing
2017-07-01
Empirical analysis of the price fluctuations of financial markets has received extensive attention because a substantial amount of financial market data has been collected and because of advances in data-mining techniques. Price fluctuation trends can help investors to make informed trading decisions, but such decisions may also be affected by a psychological factors-the anchoring effect. This study explores the intraday price time series of Taiwan futures, and applies diffusion model and quantitative methods to analyze the relationship between the anchoring effect and price fluctuations during first passage process. Our results indicate that power-law scaling and anomalous diffusion for stock price fluctuations are related to the anchoring effect. Moreover, microscopic price fluctuations before switching point in first passage process correspond with long-term price fluctuations of Taiwan's stock market. We find that microscopic trends could provide useful information for understanding macroscopic trends in stock markets.
Positioning, Splinting, and Contracture Management
2011-01-01
IP) joints in extension, thumb in palmar abduction, hip extension and abducted 20 (no external rotation), knee extension, and neutral ankle ...to skin breakdown are the heels,55 sacrum, ankles , wrists, elbows, and occipital area.8 Some options for splinting and positioning devices can be...children.70 In addition, moveable parts are difficult to anchor to small levers and the cognition and responsibilities needed for proper fit of dynamic
ERIC Educational Resources Information Center
Moller, Valerie; Theuns, Peter; Erstad, Ida; Bernheim, Jan
2008-01-01
The Anamnestic Comparative Self Assessment (ACSA) measure of subjective well-being (SWB) aims to reduce the problems of cultural bias and relativity to external standards by allowing people to define the endpoints or "anchors" of the measurement scale. In medical terminology anamnestic denotes "based on memory". The ACSA uses…
Using Anchoring Vignettes to Adjust Self-Reported Personality: A Comparison Between Countries
Weiss, Selina; Roberts, Richard D.
2018-01-01
Data from self-report tools cannot be readily compared between cultures due to culturally specific ways of using a response scale. As such, anchoring vignettes have been proposed as a suitable methodology for correcting against this difference. We developed anchoring vignettes for the Big Five Inventory-44 (BFI-44) to supplement its Likert-type response options. Based on two samples (Rwanda: n = 423; Philippines: n = 143), we evaluated the psychometric properties of the measure both before and after applying the anchoring vignette adjustment. Results show that adjusted scores had better measurement properties, including improved reliability and a more orthogonal correlational structure, relative to scores based on the original Likert scale. Correlations of the Big Five Personality Factors with life satisfaction were essentially unchanged after the vignette-adjustment while correlations with counterproductive were noticeably lower. Overall, these changed findings suggest that the use of anchoring vignette methodology improves the cross-cultural comparability of self-reported personality, a finding of potential interest to the field of global workforce research and development as well as educational policymakers. PMID:29593621
Fingerprinting and quantification of GMOs in the agro-food sector.
Taverniers, I; Van Bockstaele, E; De Loose, M
2003-01-01
Most strategies for analyzing GMOs in plants and derived food and feed products, are based on the polymerase chain reaction (PCR) technique. In conventional PCR methods, a 'known' sequence between two specific primers is amplified. To the contrary, with the 'anchor PCR' technique, unknown sequences adjacent to a known sequence, can be amplified. Because T-DNA/plant border sequences are being amplified, anchor PCR is the perfect tool for unique identification of transgenes, including non-authorized GMOs. In this work, anchor PCR was applied to characterize the 'transgene locus' and to clarify the complete molecular structure of at least six different commercial transgenic plants. Based on sequences of T-DNA/plant border junctions, obtained by anchor PCR, event specific primers were developed. The junction fragments, together with endogeneous reference gene targets, were cloned in plasmids. The latter were then used as event specific calibrators in real-time PCR, a new technique for the accurate relative quantification of GMOs. We demonstrate here the importance of anchor PCR for identification and the usefulness of plasmid DNA calibrators in quantification strategies for GMOs, throughout the agro-food sector.
Kitt, Alexander L; Qi, Zenan; Rémi, Sebastian; Park, Harold S; Swan, Anna K; Goldberg, Bennett B
2013-06-12
Strain, bending rigidity, and adhesion are interwoven in determining how graphene responds when pulled across a substrate. Using Raman spectroscopy of circular, graphene-sealed microchambers under variable external pressure, we demonstrate that graphene is not firmly anchored to the substrate when pulled. Instead, as the suspended graphene is pushed into the chamber under pressure, the supported graphene outside the microchamber is stretched and slides, pulling in an annulus. Analyzing Raman G band line scans with a continuum model extended to include sliding, we extract the pressure dependent sliding friction between the SiO2 substrate and mono-, bi-, and trilayer graphene. The sliding friction for trilayer graphene is directly proportional to the applied load, but the friction for monolayer and bilayer graphene is inversely proportional to the strain in the graphene, which is in violation of Amontons' law. We attribute this behavior to the high surface conformation enabled by the low bending rigidity and strong adhesion of few layer graphene.
2014-01-01
Background The purpose of the present study was to compare the results of various types of anchor applications with or without augmentation in both osteopenic and severely osteoporotic bone models. Methods Two different types of suture anchors were tested in severely osteoporotic (SOP) and osteopenic polyurethane (PU) foam blocks using an established protocol. An Instron machine applied static loading parallel to the axis of insertion until failure, and the mean anchor failure strengths were calculated. The mode of failure (anchor pullout, suture tear) was recorded. The anchors tested included the Corkscrew® (CS) (Arthrex Inc., Naples, FL, USA) (without augmentation, polymethylmethacrylate (PMMA)-augmented, and bioabsorbable tricalcium phosphate (TCP) cement-augmented) and Corkscrew® FT II (CS FT II) 5.5 mm (without augmentation as used routinely). Results The mean failure loads for both SOP and osteopenic PU foam blocks, respectively, were as follows: CS, 16.2 and 212.4 N; CS with TCP, 75.2 and 396 N; CS with PMMA, 101.2 and 528.8 N; CS FT II, 13.8 and 339.8 N. Conclusions Augmentation of CS with TCP or PMMA would be essential to SOP bones. In the osteopenic bone model, although anchor fixation augmented with PMMA is the best fixation method, CS augmented with TCP cement or CS FT II without any need for augmentation may also be used as an alternative. PMID:25148925
Effects of surface anchoring on the electric Frederiks transition in ferronematic systems
NASA Astrophysics Data System (ADS)
Farrokhbin, Mojtaba; Kadivar, Erfan
2016-11-01
The effects of anchoring phenomenon on the electric Frederiks transition threshold field in a nematic liquid crystal doped with ferroelectric nanoparticles are discussed. The polarizability of these nanoparticles in combination with confinement effects cause the drastic effects on the ferronematic systems. This study is based on Frank free energy and Rapini-Papoular surface energy for ferronematic liquid crystal having finite anchoring condition. In the case of different anchoring boundary conditions, the Euler-Lagrange equation of the total free energy is numerically solved by using the finite difference method together with the relaxation method and Maxwell construction to select the physical solutions and therefore investigate the effects of different anchoring strengths on the Frederiks transition threshold field. Maxwell construction method is employed to select three periodic solutions for nematic liquid crystal director at the interfaces of a slab. In the interval from zero to half- π, there is only one solution for the director orientation. In this way, NLC director rotates toward the normal to the surface as the applied electric field increases at the walls. Our numerical results illustrate that above Frederiks transition and in the intermediate anchoring strength, nematic molecules illustrate the different orientation at slab boundaries. We also study the effects of different anchoring strengths, nanoparticle volume fractions and polarizations on the Frederiks transition threshold field. We report that decreasing in the nanoparticle polarization results in the saturation Frederiks threshold. However, this situation does not happen for the nanoparticles volume fraction.
Microgravity Drill and Anchor System
NASA Technical Reports Server (NTRS)
Parness, Aaron; Frost, Matthew A.; King, Jonathan P.
2013-01-01
This work is a method to drill into a rock surface regardless of the gravitational field or orientation. The required weight-on-bit (WOB) is supplied by a self-contained anchoring mechanism. The system includes a rotary percussive coring drill, forming a complete sampling instrument usable by robot or human. This method of in situ sample acquisition using micro - spine anchoring technology enables several NASA mission concepts not currently possible with existing technology, including sampling from consolidated rock on asteroids, providing a bolt network for astronauts visiting a near-Earth asteroid, and sampling from the ceilings or vertical walls of lava tubes and cliff faces on Mars. One of the most fundamental parameters of drilling is the WOB; essentially, the load applied to the bit that allows it to cut, creating a reaction force normal to the surface. In every drilling application, there is a minimum WOB that must be maintained for the system to function properly. In microgravity (asteroids and comets), even a small WOB could not be supported conventionally by the weight of the robot or astronaut. An anchoring mechanism would be needed to resist the reactions, or the robot or astronaut would push themselves off the surface and into space. The ability of the system to anchor itself to a surface creates potential applications that reach beyond use in low gravity. The use of these anchoring mechanisms as end effectors on climbing robots has the potential of vastly expanding the scope of what is considered accessible terrain. Further, because the drill is supported by its own anchor rather than by a robotic arm, the workspace is not constrained by the reach of such an arm. Yet, if the drill is on a robotic arm, it has the benefit of not reflecting the forces of drilling back to the arm s joints. Combining the drill with the anchoring feet will create a highly mobile, highly stable, and highly reliable system. The drilling system s anchor uses hundreds of microspine toes that independently find holes and ledges on a rock to create an anchor. Once the system is anchored, a linear translation mechanism moves the drill axially into the surface while maintaining the proper WOB. The linear translation mechanism is composed of a ball screw and stepper motor that can translate a carriage with high precision and applied load. The carriage slides along rails using self-aligning linear bearings that correct any axial misalignment caused by bending and torsion. The carriage then compresses a series of springs that simultaneously transmit the load to the drill along the bit axis and act as a suspension that compensates for the vibration caused by percussive drilling. The drill is a compacted, modified version of an off-the-shelf rotary percussive drill, which uses a custom carbide-tipped coring bit. By using rotary percussive drilling, the drill time is greatly reduced. The percussive action fractures the rock debris, which is removed during rotation. The final result is a 0.75-in. (.1.9- cm) diameter hole and a preserved 0.5- in. (.1.3-cm) diameter rock core. This work extends microspine technology, making it applicable to astronaut missions to asteroids and a host of robotic sampling concepts. At the time of this reporting, it is the first instrument to be demonstrated using microspine anchors, and is the first self-contained drill/anchor system to be demonstrated that is capable of drilling in inverted configurations and would be capable of drilling in microgravity.
Mulas, Marcello; Waniek, Nicolai; Conradt, Jörg
2016-01-01
After the discovery of grid cells, which are an essential component to understand how the mammalian brain encodes spatial information, three main classes of computational models were proposed in order to explain their working principles. Amongst them, the one based on continuous attractor networks (CAN), is promising in terms of biological plausibility and suitable for robotic applications. However, in its current formulation, it is unable to reproduce important electrophysiological findings and cannot be used to perform path integration for long periods of time. In fact, in absence of an appropriate resetting mechanism, the accumulation of errors over time due to the noise intrinsic in velocity estimation and neural computation prevents CAN models to reproduce stable spatial grid patterns. In this paper, we propose an extension of the CAN model using Hebbian plasticity to anchor grid cell activity to environmental landmarks. To validate our approach we used as input to the neural simulations both artificial data and real data recorded from a robotic setup. The additional neural mechanism can not only anchor grid patterns to external sensory cues but also recall grid patterns generated in previously explored environments. These results might be instrumental for next generation bio-inspired robotic navigation algorithms that take advantage of neural computation in order to cope with complex and dynamic environments. PMID:26924979
NASA's International Lunar Network Anchor Nodes and Robotic Lunar Lander Project Update
NASA Technical Reports Server (NTRS)
Morse, Brian J.; Reed, Cheryl L. B.; Kirby, Karen W.; Cohen, Barbara A.; Bassler, Julie A.; Harris, Danny W.; Chavers, D. Gregory
2010-01-01
In early 2008, NASA established the Lunar Quest Program, a new lunar science research program within NASA s Science Mission Directorate. The program included the establishment of the anchor nodes of the International Lunar Network (ILN), a network of lunar science stations envisioned to be emplaced by multiple nations. This paper describes the current status of the ILN Anchor Nodes mission development and the lander risk-reduction design and test activities implemented jointly by NASA s Marshall Space Flight Center and The Johns Hopkins University Applied Physics Laboratory. The lunar lander concepts developed by this team are applicable to multiple science missions, and this paper will describe a mission combining the functionality of an ILN node with an investigation of lunar polar volatiles.
NASA Astrophysics Data System (ADS)
Lorke, A.; Bodmer, P.; Noss, C.; Alshboul, Z.; Koschorreck, M.; Somlai-Haase, C.; Bastviken, D.; Flury, S.; McGinnis, D. F.; Maeck, A.; Müller, D.; Premke, K.
2015-12-01
Stream networks have recently been discovered to be major but poorly constrained natural greenhouse gas (GHG) sources. A fundamental problem is that several measurement approaches have been used without cross-comparisons. Flux chambers represent a potentially powerful methodological approach if robust and reliable ways to use chambers on running water can be defined. Here we compare the use of anchored and freely drifting chambers on various streams with different flow velocities. The study clearly shows that (1) anchored chambers enhance turbulence under the chambers and thus elevate fluxes, (2) drifting chambers have a very small impact on the water turbulence under the chamber and thus generate more reliable fluxes, (3) the bias of the anchored chambers greatly depends on chamber design and sampling conditions, and (4) there is a promising method to reduce the bias from anchored chambers by using a flexible plastic foil collar to seal the chambers to the water surface, rather than having rigid chamber walls penetrating into the water. Altogether, these results provide novel guidance on how to apply flux chambers in running water, which will have important consequences for measurements to constrain the global GHG balances.
NASA Astrophysics Data System (ADS)
Lorke, A.; Bodmer, P.; Noss, C.; Alshboul, Z.; Koschorreck, M.; Somlai, C.; Bastviken, D.; Flury, S.; McGinnis, D. F.; Maeck, A.; Müller, D.; Premke, K.
2015-09-01
Stream networks were recently discovered as major but poorly constrained natural greenhouse gas (GHG) sources. A fundamental problem is that several measurement approaches have been used without cross comparisons. Flux chambers represent a potentially powerful methodological approach if robust and reliable ways to use chambers on running water can be defined. Here we compare the use of anchored and freely drifting chambers on various streams having different flow velocities. The study clearly shows that (1) drifting chambers have a very small impact on the water turbulence under the chamber and thus generate more reliable fluxes, (2) anchored chambers enhance turbulence under the chambers and thus elevate fluxes, (3) the bias of the anchored chambers greatly depends on chamber design and sampling conditions, and (4) there is a promising method to reduce the bias from anchored chambers by using a flexible plastic foil seal to the water surface rather than having rigid chamber walls penetrating into the water. Altogether, these results provide novel guidance on how to apply flux chambers in running water, which will have important consequences for measurements to constrain the global GHG balances.
PrPC Undergoes Basal to Apical Transcytosis in Polarized Epithelial MDCK Cells
Arkhipenko, Alexander; Syan, Sylvie; Victoria, Guiliana Soraya
2016-01-01
The Prion Protein (PrP) is an ubiquitously expressed glycosylated membrane protein attached to the external leaflet of the plasma membrane via a glycosylphosphatidylinositol anchor (GPI). While the misfolded PrPSc scrapie isoform is the infectious agent of prion disease, the cellular isoform (PrPC) is an enigmatic protein with unclear function. Of interest, PrP localization in polarized MDCK cells is controversial and its mechanism of trafficking is not clear. Here we investigated PrP traffic in MDCK cells polarized on filters and in three-dimensional MDCK cysts, a more physiological model of polarized epithelia. We found that, unlike other GPI-anchored proteins (GPI-APs), PrP undergoes basolateral-to-apical transcytosis in fully polarized MDCK cells. Following this event full-length PrP and its cleavage fragments are segregated in different domains of the plasma membrane in polarized cells in both 2D and 3D cultures. PMID:27389581
DOE Office of Scientific and Technical Information (OSTI.GOV)
Souza, R.F. de; Yang, D.-Ke; Lenzi, E.K.
2014-07-15
An analytical expression for the relaxation time of a nematic liquid crystal is obtained for the first time by considering the influence of surface viscosity, anchoring energy strength and cell gap, validated numerically by using the so-called relaxation method. This general equation for the molecular response time (τ{sub 0}) was derived for a vertical aligned cell and by solving an eigenvalue equation coming from the usual balance of torque equation in the Derzhanskii and Petrov formulation, recovering the usual equations in the appropriate limit. The results show that τ∼d{sup b}, where b=2 is observed only for strongly anchored cells, whilemore » for moderate to weak anchored cells, the exponent lies between 1 and 2, depending on both, surface viscosity and anchoring strength. We found that the surface viscosity is important when calculating the response time, specially for thin cells, critical for liquid crystal devices. The surface viscosity’s effect on the optical response time with pretilt is also explored. Our results bring new insights about the role of surface viscosity and its effects in applied physics. - Highlights: • The relaxation of nematic liquid crystals is calculated by taking the surface viscosity into account. • An analytical expression for the relaxation time depending on surface viscosity, anchoring strength and cell gap is obtained. • The results are numerically verified. • Surface viscosity is crucial for thin and weak anchored cells. • The effect on optical time and pretilt angle is also studied.« less
Anchoring bias in online voting
NASA Astrophysics Data System (ADS)
Yang, Zimo; Zhang, Zi-Ke; Zhou, Tao
2012-12-01
Voting online with explicit ratings could largely reflect people's preferences and objects' qualities, but ratings are always irrational, because they may be affected by many unpredictable factors like mood, weather and other people's votes. By analyzing two real systems, this paper reveals a systematic bias embedding in the individual decision-making processes, namely people tend to give a low rating after a low rating, as well as a high rating following a high rating. This so-called anchoring bias is validated via extensive comparisons with null models, and numerically speaking, the extent of bias decays with voting interval in a logarithmic form. Our findings could be applied in the design of recommender systems and considered as important complementary materials to previous knowledge about anchoring effects on financial trades, performance judgments, auctions, and so on.
Frassanito, Paolo; Massimi, Luca; Tamburrini, Gianpiero; Pittiruti, Mauro; Doglietto, Francesco; Nucci, Carlotta Ginevra; Caldarelli, Massimo
2016-09-01
Accidental dislocation or removal is a well-known complication of external cerebrospinal fluid (CSF) drainage in daily clinical practice. At present, no data about the incidence of such complications are available in the scientific literature. SecurAcath (Interrad Medical, Plymouth, Minnesota, USA) is a subcutaneously anchored device recently adopted for securement of central venous catheters, known to be highly effective (and cost-effective) in reducing the risk of catheter dislodgement and/or accidental removal. We report our preliminary experience with the use of SecurAcath to secure CSF drainage, either ventricular or spinal, to the skin. SecurAcath was used in 29 consecutive patients (age range: 3 weeks-16 years, median age 6.3 years). In particular, the device was used for 25 ventricular catheters (a patient received 2 catheters in the same procedure for bilateral brain abscess) and 5 spinal drainages. Period in place ranged from 1-4 weeks (median 22 days). No complication related to the use of the device was observed, in particular there was no case of dislocation or accidental removal of the catheter. The removal procedure was extremely easy. The device has proven its utility also in 3 cases requiring an adjustment of the length of the catheter. In our experience, SecurAcath is a safe and effective device to secure CSF external catheters to the skin, with several relevant advantages: its placement and maintenance are easy; it may stay in place for the entire duration of the catheter; it allows a more complete antisepsis of the exit site, thus reducing local skin complications; it eliminates the risk of suture-related needlestick injuries. Copyright © 2016 Elsevier Inc. All rights reserved.
Tovkach, O M; Chernyshuk, S B; Lev, B I
2012-12-01
We develop the method proposed by Chernyshuk and Lev [Phys. Rev. E 81, 041701 (2010)] for theoretical investigation of elastic interactions between colloidal particles of arbitrary shape and chirality (polar as well as azimuthal anchoring) in the confined nematic liquid crystal (NLC). General expressions for six different types of multipole elastic interactions are obtained in the confined NLC: monopole-monopole (Coulomb type), monopole-dipole, monopole-quadrupole, dipole-dipole, dipole-quadrupole, and quadrupole-quadrupole interactions. The obtained formulas remain valid in the presence of the external electric or magnetic fields. The exact equations are found for all multipole coefficients for the weak anchoring case. For the strong anchoring coupling, the connection between the symmetry of the shape or director and multipole coefficients is obtained, which enables us to predict which multipole coefficients vanish and which remain nonzero. The particles with azimuthal helicoid anchoring are considered as an example. Dipole-dipole interactions between helicoid cylinders and cones are found in the confined NLC. In addition, the banana-shaped particles in homeotropic and planar nematic cells are considered. It is found that the dipole-dipole interaction between banana-shaped particles differs greatly from the dipole-dipole interaction between the axially symmetrical particles in the nematic cell. There is a crossover from attraction to repulsion between banana particles along some directions in nematic cells. It is shown that monopoles do not "feel" the type of nematic cell: monopole-monopole interaction turns out to be the same in homeotropic and planar nematic cells and converges to the Coulomb law as thickness increases, L→∞.
Fischer, Andreas; Bausch, Dirk; Richter-Schrag, Hans-Juergen
2013-02-01
The use of self-expandable stents to treat postoperative leaks and fistula in the upper gastrointestinal (GI) tract is an established treatment for leaks of the upper GI tract. However, lumen-to-stent size discrepancies (i.e., after sleeve gastrectomy or esophageal resection) may lead to insufficient sealing of the leaks requiring further surgical intervention. This is mainly due to the relatively small diameter (≤30 mm) of commonly used commercial stents. To overcome this problem, we developed a novel partially covered stent with a shaft diameter of 36 mm and a flare diameter of 40 mm. From September 2008 to September 2010, 11 consecutive patients with postoperative leaks were treated with the novel large diameter stent (gastrectomy, n = 5; sleeve gastrectomy, n = 2; fundoplication after esophageal perforation, n = 2; Roux-en-Y gastric bypass, n = 1; esophageal resection, n = 1). Treatment with commercially available stents (shaft/flare: 23/28 mm and 24/30 mm) had been unsuccessful in three patients before treatment with the large diameter stent. Due to dislocation, the large diameter stent was anchored in four patients (2× intraoperatively with transmural sutures, 2× endoscopically with transnasally externalized threads). Treatment was successful in 11 of 11 patients. Stent placement and removal was easy and safe. The median residence time of the stent was 24 (range, 18-41) days. Stent dislocation occurred in four cases (36 %). It was treated by anchoring the stent. Mean follow-up was 25 (range, 14-40) months. No severe complication occurred during or after intervention and no patient was dysphagic. Using the novel large diameter, partially covered stent to seal leaks in the upper GI tract is safe and effective. The large diameter of the stent does not seem to injure the wall of the upper GI tract. However, stent dislocation sometimes requires anchoring of the stent with sutures or transnasally externalized threads.
Uruc, Vedat; Ozden, Raif; Dogramacı, Yunus; Kalacı, Aydıner; Hallaceli, Hasan; Küçükdurmaz, Fatih
2014-01-01
The aim of this study was to test a simple technique to augment the pullout resistance of an anchor in an over-drilled sheep humerus model. Sixty-four paired sheep humeri were harvested from 32 male sheep aged 18 months. Specimens were divided into an augmented group and non-augmented group. FASTIN RC 5-mm titanium screw anchors (DePuy Mitek, Raynham, MA) double loaded with suture material (braided polyester, nonabsorbable USP No. 2) were used in both groups. Osteoporosis was simulated by over-drilling with a 4.5-mm drill. Augmentation was performed by fixing 1 of the sutures 1.5 cm inferior to the anchor insertion site with a washer screw. This was followed by a pull-to-failure test at 50 mm/min. The ultimate load (the highest value of strength before anchor pullout) was recorded. A paired t test was used to compare the biomechanical properties of the augmented and non-augmented groups. In all specimens the failure mode was pullout of the anchor. The ultimate failure loads were statistically significantly higher in the augmented group (P < .0001). The mean pullout strength was 121.1 ± 10.17 N in the non-augmented group and 176.1 ± 10.34 N in the augmented group. The described augmentation technique, which is achieved by inferior-lateral fixation of 1 of the sutures of the double-loaded anchor to a fully threaded 6.5-mm cancellous screw with a washer, significantly increases the ultimate failure loads in the over-drilled sheep humerus model. Our technique is simple, safe, and inexpensive. It can be easily used in all osteoporotic patients and will contribute to the reduction of anchor failure. This technique might be difficult to apply arthroscopically. Cannulated smaller screws would probably be more practical for arthroscopic use. Further clinical studies are needed. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Bone anchors or interference screws? A biomechanical evaluation for autograft ankle stabilization.
Jeys, Lee; Korrosis, Sotiris; Stewart, Todd; Harris, Nicholas J
2004-01-01
Autograft stabilization uses free semitendinosus tendon grafts to anatomically reconstruct the anterior talofibular ligament. Study aims were to evaluate the biomechanical properties of Mitek GII anchors compared with the Arthrex Bio-Tenodesis Screw for free tendon reconstruction of the anterior talofibular ligament. There are no differences in load to failure and percentage specimen elongation at failure between the 2 methods. Controlled laboratory study using porcine models. Sixty porcine tendon constructs were failure tested. Re-creating the pull of the anterior talofibular ligament, loads were applied at 70 degrees to the bones. Thirty-six tendons were fixed to porcine tali and tested using a single pull to failure; 10 were secured with anchors and No. 2 Ethibond, 10 with anchors and FiberWire, 10 with screws and Fiberwire, and 6 with partially gripped screws. Cyclic preloading was conducted on 6 tendons fixed by anchors and on 6 tendons fixed by screws before failure testing. Two groups of 6 components fixed to the fibula were also tested. The talus single-pull anchor group produced a mean load of 114 N and elongation of 37% at failure. The talus single-pull screw group produced a mean load of 227 N and elongation of 22% at failure (P <.05). Cyclic preloading at 65% failure load before failure testing produced increases in load and decreases in elongation at failure. Partially gripped screws produced a load of 133 N and elongation of 30% at failure. The fibula model produced significant increases in load to failure for both. The human anterior talofibular ligament has loads of 139 N at failure with instability occurring at 20% elongation. Interference screw fixation produced significantly greater failure strength and less elongation at failure than bone anchors. The improved biomechanics of interference screws suggests that these may be more suited to in vivo reconstruction of the anterior talofibular ligament than are bone anchors.
Francàs, Laia; Richmond, Craig; Garrido-Barros, Pablo; Planas, Nora; Roeser, Stephan; Benet-Buchholz, Jordi; Escriche, Lluís; Sala, Xavier; Llobet, Antoni
2016-04-04
Three distinct functionalisation strategies have been applied to the in,in-[{Ru(II)(trpy)}2(μ-bpp)(H2O)2](3+) (trpy=2,2':6',2''-terpyridine, bpp=bis(pyridine)pyrazolate) water-oxidation catalyst framework to form new derivatives that can adsorb onto titania substrates. Modifications included the addition of sulfonate, carboxylate, and phosphonate anchoring groups to the terpyridine and bis(pyridyl)pyrazolate ligands. The complexes were characterised in solution by using 1D NMR, 2D NMR, and UV/Vis spectroscopic analysis and electrochemical techniques. The complexes were then anchored on TiO2-coated fluorinated tin oxide (FTO) films, and the reactivity of these new materials as water-oxidation catalysts was tested electrochemically through controlled-potential electrolysis (CPE) with oxygen evolution detected by headspace analysis with a Clark electrode. The results obtained highlight the importance of the catalyst orientation with respect to the titania surface in regard to its capacity to catalytically oxidize water to dioxygen. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, Hong-Yun; Hua, Ying-Hui; Wu, Zi-Ying; Chen, Bo; Chen, Shi-Yi
2013-11-01
The purpose of this study was to compare the biomechanical characteristics of fixation with 2-suture anchors versus transosseous tunnel fixation in anatomic reconstruction of the ankle lateral ligaments. Six matched pairs of human cadaveric ankles underwent anatomic lateral ankle reconstruction, and fixation of the graft on the talus was achieved with 2 suture anchors or a transosseous tunnel. Ankles for the transosseous tunnel group were chosen at random, with the paired contralateral ankles used for the 2-suture anchor group. Half of the peroneus brevis tendon was harvested as a graft. For each technique, one end of the tendon was secured to the original insertion point of the anterior talofibular ligament (ATFL) at the talus, whereas the other end was armed with 2 No. 5 nonabsorbable sutures (Ethicon, Somerville, NJ) and passed through the bone tunnel in the fibula. Biomechanical testing was performed by applying the force in line with the graft. Load to failure was determined at a displacement rate of 50 mm/min. The load-displacement curve, maximum load at failure (N), and stiffness (N/mm) were recorded and compared between the 2 techniques. There was no difference between constructs in the 2-suture anchor group and the transosseous tunnel group in terms of the ultimate load and stiffness (161.8 ± 47.6 N v 171.9 ± 76.0 N; P = .92; 4.59 ± 1.85 N/mm v 5.77 ± 1.98 N/mm; P = .35). Most constructs failed because of anchor pullout in the 2-suture anchor group (5 of 6) and fracture of the bony bridge in the transosseous tunnel group (6 of 6). The strength of fixation with suture anchors in anatomic reconstruction of the ankle lateral ligaments was equivalent to transosseous tunnel fixation as determined with biomechanical testing. However, this study did not prove that one is advantageous over the other. Both techniques showed excellent biomechanical results. Therefore, the 2-suture anchor fixation approach can be safely used in anatomic reconstruction of the ankle lateral ligaments. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
1982-05-01
mineral wool insulation had delaminated in several areas, causing blockages to the cooling jacket fan. The incinerator walls were now exposed as shown...walls, respec- tively. The insulation is a pressed mineral wool , 2 in. thick. The wire ties, connected to the anchors, were used to support an external...covered with a mineral wool blanket, that was tightly fitted into the 12-in. duct. The seams were covered with a high- temperature silicone rubber to
A light- and calcium-gated transcription factor for imaging and manipulating activated neurons
Wang, W.; Wildes, C. P.; Pattarabanjird, T.; Sanchez, M. I.; Glober, G.F.; Matthews, G. A.; Tye, K. M.; Ting, A. Y
2017-01-01
Activity remodels neurons, altering their molecular, structural, and electrical characteristics. To enable the selective characterization and manipulation of these neurons, we present FLARE, an engineered transcription factor that drives expression of fluorescent proteins, opsins, and other genetically-encoded tools only in the subset of neurons that experienced activity during a user-defined time window. FLARE senses the coincidence of elevated cytosolic calcium and externally-applied blue light, which together produce translocation of a membrane-anchored transcription factor to the nucleus to drive expression of any transgene. In cultured rat neurons, FLARE gives a light-to-dark signal ratio of 120 and a high-to-low calcium signal ratio of 10 after 10 minutes of stimulation. Channelrhodopsin expression permitted functional manipulation of FLARE-marked neurons. In adult mice, FLARE also gave light- and motor activity-dependent transcription in the cortex. Due to its modular design, minute-scale temporal resolution, and minimal dark-state leak, FLARE should be useful for the study of activity-dependent processes in neurons and other cells that signal with calcium. PMID:28650461
A light- and calcium-gated transcription factor for imaging and manipulating activated neurons.
Wang, Wenjing; Wildes, Craig P; Pattarabanjird, Tanyaporn; Sanchez, Mateo I; Glober, Gordon F; Matthews, Gillian A; Tye, Kay M; Ting, Alice Y
2017-09-01
Activity remodels neurons, altering their molecular, structural, and electrical characteristics. To enable the selective characterization and manipulation of these neurons, we present FLARE, an engineered transcription factor that drives expression of fluorescent proteins, opsins, and other genetically encoded tools only in the subset of neurons that experienced activity during a user-defined time window. FLARE senses the coincidence of elevated cytosolic calcium and externally applied blue light, which together produce translocation of a membrane-anchored transcription factor to the nucleus to drive expression of any transgene. In cultured rat neurons, FLARE gives a light-to-dark signal ratio of 120 and a high- to low-calcium signal ratio of 10 after 10 min of stimulation. Opsin expression permitted functional manipulation of FLARE-marked neurons. In adult mice, FLARE also gave light- and motor-activity-dependent transcription in the cortex. Due to its modular design, minute-scale temporal resolution, and minimal dark-state leak, FLARE should be useful for the study of activity-dependent processes in neurons and other cells that signal with calcium.
Nordman, Nina; Barrios-Lopez, Brianda; Laurén, Susanna; Suvanto, Pia; Kotiaho, Tapio; Franssila, Sami; Kostiainen, Risto; Sikanen, Tiina
2015-02-01
We report a simple protocol for fabrication of shape-anchored porous polymer monoliths (PPMs) for on-chip SPE prior to online microchip electrophoresis (ME) separation and on-chip (ESI/MS). The chip design comprises a standard ME separation channel with simple cross injector and a fully integrated ESI emitter featuring coaxial sheath liquid channel. The monolith zone was prepared in situ at the injection cross by laser-initiated photopolymerization through the microchip cover layer. The use of high-power laser allowed not only maskless patterning of a precisely defined monolith zone, but also faster exposure time (here, 7 min) compared with flood exposure UV lamps. The size of the monolith pattern was defined by the diameter of the laser output (∅500 μm) and the porosity was geared toward high through-flow to allow electrokinetic actuation and thus avoid coupling to external pumps. Placing the monolith at the injection cross enabled firm anchoring based on its cross-shape so that no surface premodification with anchoring linkers was needed. In addition, sample loading and subsequent injection (elution) to the separation channel could be performed similar to standard ME setup. As a result, 15- to 23-fold enrichment factors were obtained already at loading (preconcentration) times as short as 25 s without sacrificing the throughput of ME analysis. The performance of the SPE-ME-ESI/MS chip was repeatable within 3.1% and 11.5% RSD (n = 3) in terms of migration time and peak height, respectively, and linear correlation was observed between the loading time and peak area. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Ammar Khodja, L'Hady
The rehabilitation and strengthening concrete structures in shear using composite materials such as externally bonded (EB) or near surface mounted rebar (NSMR) are well established techniques. However, debonding of these strengthening materials is still present and constitute the principal cause of shear failure of beams strengthened with composite materials. A new method called ETS (Embedded Through Section) was recently developed in order to avoid premature failures due to debonding of composite materials. The objective of this study is to highlight the importance and influence of important parameters on the behavior of CFRP bars anchorages subjected to pullout forces. These parameters are: concrete strength, anchorage length of CFRP bars, hole diameter in concrete, diameter of the bar and CFRP surface type (smooth versus sanded). Understanding the influence of these parameters on the relationship between the pullout force and the slip is paramount. This allows an accurate description of the behavior of all elements that contribute to the resistance of the CFRP bars pullout. A series of 25 specimens were subjected to pullout tests. The impact of these parameters on the pullout performance of CFRP rods is summarized in terms of failure mode, ultimate tensile strength and loading force slip relationship. The results of these investigations show that using the ETS method, failure of the anchors can be avoided by providing adequate anchorage length and concrete strength. The method provides greater confinement and thus leads to a substantial improvement in the performance of anchors. As a result, designers will be able to avoid failures that are due to debonding of anchors using thereby the full capabilities of reinforced beams strengthened in shear with EB FRP. Keywords: ETS method, shear, strengthening, anchor, slip, FRP, NSM.
Repair of type-2 SLAP lesions using Corkscrew anchors. A preliminary report of the clinical results.
Kartus, Jüri; Kartus, Catarina; Brownlow, Harry; Burrow, Greggory; Perko, Mark
2004-05-01
The aim of the study was to perform a clinical assessment of patients who had undergone arthroscopic repair of a type-2 SLAP lesion using one double-looped Corkscrew anchor. Fifteen consecutive patients who agreed to fill in a pre- and post-operative questionnaire were included in the study. The aetiology was traumatic in 10/15 patients and non-traumatic in 5/15. At the index operation four patients underwent a concomitant acromioplasty, while four patients underwent supplementary anterior labrum fixation using suture anchors. Thirteen/15 (87%) of the patients were physically re-examined by independent observers after a follow-up period of 25 months (11-32). The questionnaire involved a patient-administered assessment of ten common activities of daily living. At follow-up, the Rowe score was 84 points (51-98) and the Constant score was 83 points (35-100). The external rotation in abduction was 85 degrees (60-110) on the operated side and 90 degrees (80-110) on the non-operated side ( p<0.05). The isometric strength in abduction was 8.3 kg (0.8-14.4) on the operated side and 8.9 kg (2.7-15.5) on the non-operated side ( p=0.006). Significant improvements ( p<0.05) compared with the pre-operative assessments were found in 2/10 activities of daily living. Another 4/10 activities seemed to improve but did not reach statistical significance ( p<0.08). Eleven of 15 patients returned to their pre-injury activity level. In conclusion, the majority of patients returned to their pre-injury activity level and the subjective patient-administered evaluations appeared to improve after arthroscopic repair of type-2 SLAP lesions using one double-looped Corkscrew anchor. We feel encouraged to continue using this technique.
Jackson, Rebecca D; Best, Thomas M; Borlawsky, Tara B; Lai, Albert M; James, Stephen; Gurcan, Metin N
2012-01-01
The conduct of clinical and translational research regularly involves the use of a variety of heterogeneous and large-scale data resources. Scalable methods for the integrative analysis of such resources, particularly when attempting to leverage computable domain knowledge in order to generate actionable hypotheses in a high-throughput manner, remain an open area of research. In this report, we describe both a generalizable design pattern for such integrative knowledge-anchored hypothesis discovery operations and our experience in applying that design pattern in the experimental context of a set of driving research questions related to the publicly available Osteoarthritis Initiative data repository. We believe that this ‘test bed’ project and the lessons learned during its execution are both generalizable and representative of common clinical and translational research paradigms. PMID:22647689
Dermal Aged and Fetal Fibroblasts Realign in Response to Mechanical Strain
NASA Technical Reports Server (NTRS)
Sawyer, Christine; Grymes, Rose; Alvarez, Teresa (Technical Monitor)
1994-01-01
Integrins specifically recognize and bind extracellular matrix components, providing physical anchor points and functional setpoints. Focal adhesion complexes, containing integrin and cytoskeletal proteins, are potential mechanoreceptors, poised to distribute applied forces through the cytoskeleton. Pursuing the hypothesis that cells both perceive and respond to external force, we applied a stretch/relaxation regimen to normal human fetal and aged dermal fibroblast monolayers cultured on flexible membranes. The frequency and magnitude of the applied force is precisely controlled by the Flexercell Unit(Trademark). A protocol of stretch (20% elongation of the monolayer) at a frequency of 6 cycles/min caused a progressive change from a randomly distributed pattern of cells to a symmetric, radial distribution with cells aligned parallel to the applied force. We have coined the term 'orienteering' as the process of active alignment of cells in response to applied force. Cytochalasin D was added in graded doses to investigate the role of the actin cytoskeleton in force perception and transmission. A clear dose response was found; at high concentrations orienteering was abolished; and the drug's impact was reversible. The two cell strains used were similar in their alignment behavior and in their responses to cytochalasin D. Orienteering was influenced by cell density, and the cell strains studied differed in this respect. Fetal cells, unlike their aged counterparts, failed to orient at high cell density. In both cell strains, mid-density cultures aligned rapidly and sparse cultures lagged. These results indicate that both cell-cell adhesion and cytoskeleton integrity are critical in mediating the orienteering response. Differences between these two cell strains may relate to their expression of extracellular matrix molecules (fibronectin, collagen type 1) integrins and their relative binding affinities.
Elastic and hydrodynamic torques on a colloidal disk within a nematic liquid crystal.
Rovner, Joel B; Borgnia, Dan S; Reich, Daniel H; Leheny, Robert L
2012-10-01
The orientationally dependent elastic energy and hydrodynamic behavior of colloidal disks with homeotropic surface anchoring suspended in the nematic liquid crystal 4-cyano-4'-pentylbiphenyl (5CB) have been investigated. In the absence of external torques, the disks align with the normal of the disk face â parallel to the nematic director n[over ^]. When a magnetic field is applied, the disks rotate â by an angle θ so that the magnetic torque and the elastic torque caused by distortion of the nematic director field are balanced. Over a broad range of angles, the elastic torque increases linearly with θ in quantitative agreement with a theoretical prediction based on an electrostatic analogy. When the disks are rotated to angles θ>π/2, the resulting large elastic distortion makes the disk orientation unstable, and the director undergoes a topological transition in which θ→π-θ. In the transition, a defect loop is shed from the disk surface, and the disks spin so that â sweeps through π radians as the loop collapses back onto the disk. Additional measurements of the angular relaxation of disks to θ=0 following removal of the external torque show a quasi-exponential time dependence from which an effective drag viscosity for the nematic can be extracted. The scaling of the angular time dependence with disk radius and observations of disks rotating about â indicate that the disk motion affects the director field at surprisingly modest Ericksen numbers.
α-Actinin/titin interaction: A dynamic and mechanically stable cluster of bonds in the muscle Z-disk
Grison, Marco; Merkel, Ulrich; Kostan, Julius; Djinović-Carugo, Kristina; Rief, Matthias
2017-01-01
Stable anchoring of titin within the muscle Z-disk is essential for preserving muscle integrity during passive stretching. One of the main candidates for anchoring titin in the Z-disk is the actin cross-linker α-actinin. The calmodulin-like domain of α-actinin binds to the Z-repeats of titin. However, the mechanical and kinetic properties of this important interaction are still unknown. Here, we use a dual-beam optical tweezers assay to study the mechanics of this interaction at the single-molecule level. A single interaction of α-actinin and titin turns out to be surprisingly weak if force is applied. Depending on the direction of force application, the unbinding forces can more than triple. Our results suggest a model where multiple α-actinin/Z-repeat interactions cooperate to ensure long-term stable titin anchoring while allowing the individual components to exchange dynamically. PMID:28096424
Grison, Marco; Merkel, Ulrich; Kostan, Julius; Djinović-Carugo, Kristina; Rief, Matthias
2017-01-31
Stable anchoring of titin within the muscle Z-disk is essential for preserving muscle integrity during passive stretching. One of the main candidates for anchoring titin in the Z-disk is the actin cross-linker α-actinin. The calmodulin-like domain of α-actinin binds to the Z-repeats of titin. However, the mechanical and kinetic properties of this important interaction are still unknown. Here, we use a dual-beam optical tweezers assay to study the mechanics of this interaction at the single-molecule level. A single interaction of α-actinin and titin turns out to be surprisingly weak if force is applied. Depending on the direction of force application, the unbinding forces can more than triple. Our results suggest a model where multiple α-actinin/Z-repeat interactions cooperate to ensure long-term stable titin anchoring while allowing the individual components to exchange dynamically.
Current Status of the International Lunar Network (ILN) Anchor Nodes Mission
NASA Astrophysics Data System (ADS)
Cohen, Barbara; Bassler, J.; Harris, D.; Morse, B.; Reed, C.; Kirby, K.; Eng, D.
2009-09-01
NASA's Science Mission Directorate's (SMD) International Lunar Network Anchor Nodes Mission continues its concept development and is scheduled to complete the first formal milestone gate of a Mission Concept Review (MCR) in late 2009. The mission will establish two-four nodes of the International Lunar Network (ILN), a network of lunar geophysical stations envisioned to be emplaced by the many nations collaborating on this joint endeavor. This mission will operate over six years or more and make significant progress in satisfying many of the National Research Council's lunar science objectives, while strategically contributing to the U.S. Vision for Space Exploration Policy's objective for a robust robotic lunar program. This paper will provide a status report on the ILN Anchor Nodes mission and overview of the concept to date, which is being implemented jointly by NASA's Marshall Space Flight Center and The Johns Hopkins University Applied Physics Laboratory.
Gonzales, Matthew J.; Vincent, Kevin P.; Rappel, Wouter-Jan; Narayan, Sanjiv M.; McCulloch, Andrew D.
2014-01-01
Aims The aim of this study was to investigate structural contributions to the maintenance of rotors in human atrial fibrillation (AF) and possible mechanisms of termination. Methods and results A three-dimensional human biatrial finite element model based on patient-derived computed tomography and arrhythmia observed at electrophysiology study was used to study AF. With normal physiological electrical conductivity and effective refractory periods (ERPs), wave break failed to sustain reentrant activity or electrical rotors. With depressed excitability, decreased conduction anisotropy, and shorter ERP characteristic of AF, reentrant rotors were readily maintained. Rotors were transiently or permanently trapped by fibre discontinuities on the lateral wall of the right atrium near the tricuspid valve orifice and adjacent to the crista terminalis, both known sites of right atrial arrhythmias. Modelling inexcitable regions near the rotor tip to simulate fibrosis anchored the rotors, converting the arrhythmia to macro-reentry. Accordingly, increasing the spatial core of inexcitable tissue decreased the frequency of rotation, widened the excitable gap, and enabled an external wave to impinge on the rotor core and displace the source. Conclusion These model findings highlight the importance of structural features in rotor dynamics and suggest that regions of fibrosis may anchor fibrillatory rotors. Increasing extent of fibrosis and scar may eventually convert fibrillation to excitable gap reentry. Such macro-reentry can then be eliminated by extending the obstacle or by external stimuli that penetrate the excitable gap. PMID:25362167
Optimization of robotic welding procedures for maintenance repair of hydraulic turbines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lamarche, L.; Galopin, M.; Simoneau, R.
1996-12-31
A six axes super-compact robot is used for field repair of cavitation damages found on the discharge ring of hydraulic turbines. Optimization of overlay welding procedures to minimize surface distortion and reduce tearing forces on anchors in concrete, were studied through experimentation and FEM modelling. Planned experimentation has been used to develop optimum pulsed GMAW schedules of stainless steel overlays in 2G position. Best welding sequence was resolved through over lay welding of free plates. Each overlay consisted in one or two layers which were welded in the longitudinal and/or transverse direction of the rectangular plate. A bidirectional welding mode,more » a longitudinal layer followed by a transverse layer position and no cooling between the two layers, were found to be most effective in reducing distortion. The optimized 2G welding procedure was applied to a simulated field repair. Plate was anchored on a massive iron bracket with a set of instrumented bolts, to understand how normal tearing forces in anchors evolve. Preliminary results on FEM modelling of lateral force on anchors indicate good correlation with experiments, for an elementary design.« less
Rosa, M; Lucchi, P; Mariani, L; Caprioglio, A
2012-09-01
The purpose of this study was to evaluate the effectiveness of Haas RPE anchored on deciduous teeth in the early mixed dentition, for inducing the spontaneous correction of permanent incisor's crossbite, without compliance, without post bite-plane and no involvement of the permanent teeth. The sample group comprised 50 consecutive patients (mean age 8y 5m, SD 2y 1m), 31 males, 19 females. They showed a cross-bite affecting one or more permanent incisors, for a total of 70 teeth. The patients were treated with Haas RPE appliance anchored on second deciduous molars and bonded on deciduous canines. No direct forces were applied on the permanent teeth. Anterior crossbite self-corrected 'spontaneously' in 84% of the cases. Lateral incisors had a higher rate of self-correction than central incisors. All hyper-divergent subjects showed a spontaneous crossbite self-correction. The early maxillary expansion by Haas RPE anchored on deciduous teeth is an efficient and effective procedure to induce the anterior crossbite self-correction in the early mixed dentition without the need of a bite-plane, no involvement of the permanent teeth and without compliance.
NASA Astrophysics Data System (ADS)
Ji, Xiao-Li; Xie, Zhen; Zuo, Xi; Zhang, Guang-Ping; Li, Zong-Liang; Wang, Chuan-Kui
2016-09-01
By applying density functional theory based nonequilibrium Green's function method, we theoretically investigate the electron transport properties of a zigzag-edged trigonal graphene nanoflake (ZTGNF) sandwiched between two asymmetric zigzag graphene nanoribbon (zGNR) and armchair graphene nanoribbon (aGNR) electrodes with carbon atomic chains (CACs) as the anchoring groups. Significant rectifying effects have been observed for these molecular devices in low bias voltage regions. Interestingly, the rectifying performance of molecular devices can be optimized by changing the width of the aGNR electrode and the number of anchoring CACs. Especially, the molecular device displays giant rectification ratios up to the order of 104 when two CACs are used as the anchoring group between the ZTGNF and the right aGNR electrode. Further analysis indicates that the asymmetric shift of the perturbed molecular energy levels and the spatial parity of the electron wavefunctions in the electrodes around the Fermi level play key roles in determining the rectification performance. And the spatial distributions of tunneling electron wavefunctions under negative bias voltages can be modified to be very localized by changing the number of anchoring CACs, which is found to be the origin of the giant rectification ratios.
Is the Oswestry Disability Index a valid measure of response to sacroiliac joint treatment?
Copay, Anne G; Cher, Daniel J
2016-02-01
Disease-specific measures of the impact of sacroiliac (SI) joint pain on back/pelvis function are not available. The Oswestry Disability Index (ODI) is a validated functional measure for lower back pain, but its responsiveness to SI joint treatment has yet to be established. We sought to assess the validity of ODI to capture disability caused by SI joint pain and the minimum clinically important difference (MCID) after SI joint treatment. Patients (n = 155) participating in a prospective clinical trial of minimally invasive SI joint fusion underwent baseline and follow-up assessments using ODI, visual analog scale (VAS) pain assessment, Short Form 36 (SF-36), EuroQoL-5D, and questions (at follow-up only) regarding satisfaction with the SI joint fusion and whether the patient would have the fusion surgery again. All outcomes were compared from baseline to 12 months postsurgery. The health transition item of the SF-36 and the satisfaction scale were used as external anchors to calculate MCID. MCID was estimated for ODI using four calculation methods: (1) minimum detectable change, (2) average ODI change of patients' subsets, (3) change difference between patients' subsets, and (4) receiver operating characteristic (ROC) curve. After SI fusion, patients improved significantly (p < .0001) on all measures: SI joint pain (48.8 points), ODI (23.8 points), EQ-5D (0.29 points), EQ-5D VAS (11.7 points), PCS (8.9 points), and MCS (9.2 points). The improvement in ODI was significantly correlated (p < .0001) with SI joint pain improvement (r = .48) and with the two external anchors: SF-36 health transition item (r = .49) and satisfaction level (r = .34). The MCID values calculated for ODI using the various methods ranged from 3.5 to 19.5 points. The ODI minimum detectable change was 15.5 with the health transition item as the anchor and 13.5 with the satisfaction scale as the anchor. ODI is a valid measure of change in SI joint health. Hence, researchers and clinicians may rely on ODI scores to measure disability caused by SI pain. We estimated the MCID for ODI to be 13-15 points, which falls within the range of that previously reported for lumbar back pain and indicates that an improvement in disability should be at least 15 % to be beyond random variation.
Zhang, Tao; Wan, Chun-you; Ma, Bao-tong; Xu, Wei-guo; Mei, Xiao-long; Jia, Peng; Liu, Lei
2016-05-01
To compare clinical outcomes between two suturing methods using non absorbable materials through drilling the bone and suturing anchors for the treatment of complete rupture of the deltoid ligament. From January 2009 to January 2013, 58 hospitalized patients with ankle fracture combined with complete rupture of the deltoid ligament were treated with suturing using non absorbable materials through drilling the bone or suturing anchors. There were 29 patients who received suturing treatments using non absorbable materials through drilling the bone (Group A), including 18 males and 11 females, with an average age of (39.76 +/- 11.81) years old. According to the Lauge-Hansen classification, 12 patients had supination external rotation (SER) injuries with IV degree, 5 patients had pronation external rotation (PER) injuries with III degree, 10 patients had PER injuries with IV degrss, and 2 patients had pronation abduction injuries with III degree. There were 29 patients who received treatments with suturing using anchors (Group B), including 14 males and 15 females, with an average age of (41.79 +/- 13.28) years old. According to the Lauge-Hansen classification,9 patients had SER injuries with IV degree, 6 patients had PER injuries with III degree,13 patients had PER injuries with IV degree, and 1 patient had pronation abduction injuries with III degree. All the patients were treated with open reduction and internal fixation, as well as reconstruction of deltoid ligaments to restore the stability of the medial ankle structures. The clinical examination, imaging evaluation, American society for ankle surgery (AOFAS) ankle-hindfoot score and visual analogue scale (VAS) were used to evaluate the clinical results after operation, and the results of the two groups were compared and analyzed statistically. The follow-up duration of the 58 patients ranged from 23 to 40 months,with an average of 27.3 months. All the patients had fracture union, and the mean healing time was 12.3 weeks (ranged, 10 to 17 weeks). There were no incision complications and ankle instability. There were no significant differences between two groups in AOFAS (P=0.666) and the VAS (P=0.905). Treatments of complete rupture of the deltiod ligaments with the two suturing methods get similar good clinical effects, but the suturing using non absorbable materials through drilling the bone has several advantages such as reducing the financial burden of patients, saving social medical resources and avoiding the shortcoming in difficult removal of anchor suture.
Luo, Yuan; Szolovits, Peter
2016-01-01
In natural language processing, stand-off annotation uses the starting and ending positions of an annotation to anchor it to the text and stores the annotation content separately from the text. We address the fundamental problem of efficiently storing stand-off annotations when applying natural language processing on narrative clinical notes in electronic medical records (EMRs) and efficiently retrieving such annotations that satisfy position constraints. Efficient storage and retrieval of stand-off annotations can facilitate tasks such as mapping unstructured text to electronic medical record ontologies. We first formulate this problem into the interval query problem, for which optimal query/update time is in general logarithm. We next perform a tight time complexity analysis on the basic interval tree query algorithm and show its nonoptimality when being applied to a collection of 13 query types from Allen's interval algebra. We then study two closely related state-of-the-art interval query algorithms, proposed query reformulations, and augmentations to the second algorithm. Our proposed algorithm achieves logarithmic time stabbing-max query time complexity and solves the stabbing-interval query tasks on all of Allen's relations in logarithmic time, attaining the theoretic lower bound. Updating time is kept logarithmic and the space requirement is kept linear at the same time. We also discuss interval management in external memory models and higher dimensions.
NASA Astrophysics Data System (ADS)
Ptak, Arkadiusz; Takeda, Seiji; Nakamura, Chikashi; Miyake, Jun; Kageshima, Masami; Jarvis, Suzanne P.; Tokumoto, Hiroshi
2001-09-01
A modified atomic force microscopy (AFM) system, based on a force modulation technique, has been used to find an approximate value for the elastic modulus of a single peptide molecule directly from a mechanical test. For this purpose a self-assembled monolayer built from two kinds of peptides, reactive (able to anchor to the AFM tip) and nonreactive, was synthesized. In a typical experiment a single C3K30C (C=cysteine, K=lysine) peptide molecule was stretched between a Au(111) substrate and the gold-coated tip of an AFM cantilever to which it was attached via gold-sulfur bonds. The amplitude of the cantilever oscillations, due to an external force applied via a magnetic particle to the cantilever, was recorded by a lock-in amplifier and recalculated into stiffness of the stretched molecule. A longitudinal Young's modulus for the α-helix of a single peptide molecule and for the elongated state of this molecule has been estimated. The obtained values; 1.2±0.3 and 50±15 GPa, for the peptide α-helix and elongated peptide backbone, respectively, seem to be reasonable comparing them to the Young's modulus of protein crystals and linear organic polymers. We believe this research opens up a means by which scientists can perform quantitative studies of the elastic properties of single molecule, especially of biologically important polymers like peptides or DNA.
Luo, Yuan; Szolovits, Peter
2016-01-01
In natural language processing, stand-off annotation uses the starting and ending positions of an annotation to anchor it to the text and stores the annotation content separately from the text. We address the fundamental problem of efficiently storing stand-off annotations when applying natural language processing on narrative clinical notes in electronic medical records (EMRs) and efficiently retrieving such annotations that satisfy position constraints. Efficient storage and retrieval of stand-off annotations can facilitate tasks such as mapping unstructured text to electronic medical record ontologies. We first formulate this problem into the interval query problem, for which optimal query/update time is in general logarithm. We next perform a tight time complexity analysis on the basic interval tree query algorithm and show its nonoptimality when being applied to a collection of 13 query types from Allen’s interval algebra. We then study two closely related state-of-the-art interval query algorithms, proposed query reformulations, and augmentations to the second algorithm. Our proposed algorithm achieves logarithmic time stabbing-max query time complexity and solves the stabbing-interval query tasks on all of Allen’s relations in logarithmic time, attaining the theoretic lower bound. Updating time is kept logarithmic and the space requirement is kept linear at the same time. We also discuss interval management in external memory models and higher dimensions. PMID:27478379
Reinforcement mechanism of multi-anchor wall with double wall facing
NASA Astrophysics Data System (ADS)
Suzuki, Kouta; Kobayashi, Makoto; Miura, Kinya; Konami, Takeharu; Hayashi, Taketo
2017-10-01
The reinforced soil wall has high seismic performance as generally known. However, the seismic behavior has not been clarified accurately yet, especially on multi-anchor wall with double wall facing. Indefinite behavior of reinforced soil wall during earthquake make us complicated in case with adopting to the abutment, because of arrangement of anchor plate as reinforcement often different according to the width of roads. In this study, a series of centrifuge model tests were carried out to investigate the reinforcement mechanism of multi anchor wall with double wall facing from the perspective of the vertical earth pressure. Several types of reinforce arrangement and rigid wall were applied in order to verify the arch function in the reinforced regions. The test results show unique behavior of vertical earth pressure, which was affected by arch action. All the vertical earth pressure placed behind facing panel, are larger than that of middle part between facing panel despite of friction between backfill and facing panel. Similar results were obtained in case using rigid wall. On the other hands, the vertical earth pressure, which were measured at the 3cm high from bottom of model container, shows larger than that of bottom. This results show the existence of arch action between double walls. In addition, it implies that the wall facing of such soil structure confined the backfill as pseudo wall, which is very reason that the multi anchor wall with double wall facing has high seismic performance.
The information-anchoring model of first offers: When moving first helps versus hurts negotiators.
Loschelder, David D; Trötschel, Roman; Swaab, Roderick I; Friese, Malte; Galinsky, Adam D
2016-07-01
Does making the first offer increase or impair a negotiator's outcomes? Past research has found evidence supporting both claims. To reconcile these contradictory findings, we developed and tested an integrative model-the Information-Anchoring Model of First Offers. The model predicts when and why making the first offer helps versus hurts. We suggest that first offers have 2 effects. First, they serve as anchors that pull final settlements toward the initial first-offer value; this anchor function often produces a first-mover advantage. Second, first offers can convey information on the senders' priorities, which makes the sender vulnerable to exploitation and increases the risk of a first-mover disadvantage. To test this model, 3 experiments manipulated the information that senders communicated in their first offer. When senders did not reveal their priorities, the first-mover advantage was replicated. However, when first offers revealed senders' priorities explicitly, implicitly, or both, a first-mover disadvantage emerged. Negotiators' social value orientation moderated this effect: A first-mover disadvantage occurred when senders faced proself recipients who exploited priority information, but not with prosocial recipients. Moderated mediation analyses supported the model assumptions: Proself recipients used their integrative insight to feign priorities in their low-priority issues and thereby claimed more individual value than senders. The final discussion reviews theoretical and applied implications of the Information-Anchoring Model of First Offers. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Treatment of acute achilles tendon rupture with the panda rope bridge technique.
Yin, Liangjun; Wu, Yahong; Ren, Changsong; Wang, Yizhong; Fu, Ting; Cheng, Xiangjun; Li, Ruidong; Nie, Mao; Mu, Yuan
2018-03-01
Although nonsurgical methods and many surgical techniques have been developed for repairing a ruptured Achilles tendon, there is no consensus on its best treatment. In this article, a novel minimally invasive technique called the Panda Rope Bridge Technique (PRBT) is described. Patient with acute Achilles tendon rupture was operated on in the prone position. The PRBT begin with making the proximal bridge anchor (Krackow sutures in the myotendinous junction), the distal bridge anchor (two suture anchors in the calcaneus bone) and the ropes (threads of the suture anchors) stretched between the anchor sites. Then a small incision was made to debride and reattach the stumps of ruptured tendon. After the surgery, no cast or splint fixation was applied. All patients performed enhanced recovery after surgery (ERAS), which included immediate ankle mobilisation from day 1, full weight-bearing walking from day 5 to 7, and gradually take part in athletic exercises from 8 weeks postoperatively. PBRT was performed in 11patients with acute Achilles tendon rupture between June 2012 and June 2015. No wound infection, fistula, skin necrosis, sural nerve damage, deep venous thrombosis or tendon re-rupture was found. One year after the surgery, all patients reported 100 AOFAS ankle-hindfoot score points and the mean ATRS was 96.6. The PRBT is a simple, effective and minimally invasive technique, with no need for immobilisation of the ankle, making possible immediate and aggressive postoperative rehabilitation. Copyright © 2018 Elsevier Ltd. All rights reserved.
Maximizing coupling strength of magnetically anchored surgical instruments: how thick can we go?
Best, Sara L; Bergs, Richard; Gedeon, Makram; Paramo, Juan; Fernandez, Raul; Cadeddu, Jeffrey A; Scott, Daniel J
2011-01-01
The Magnetic Anchoring and Guidance System (MAGS) includes an external magnet that controls intra-abdominal surgical instruments via magnetic attraction forces. We have performed NOTES (Natural Orifice Transluminal Endoscopic Surgery) and LESS (Laparoendoscopic Single Site) procedures using MAGS instruments in porcine models with up to 2.5-cm-thick abdominal walls, but this distance may not be sufficient in some humans. The purpose of this study was to determine the maximal abdominal wall thickness for which the current MAGS platform is suitable. Successive iterations of prototype instruments were developed; those evaluated in this study include external (134-583 g, 38-61 mm diameter) and internal (8-39 g, 10-22 mm diameter) components using various grades, diameters, thicknesses, and stacking/shielding/focusing configurations of permanent Neodymium-iron-boron (NdFeB) magnets. Nine configurations were tested for coupling strength across distances of 0.1-10 cm. The force-distance tests across an air medium were conducted at 0.5-mm increments using a robotic arm fitted with a force sensor. A minimum theoretical instrument drop-off (decoupling) threshold was defined as the separation distance at which force decreased below the weight of the heaviest internal component (39 g). Magnetic attraction forces decreased exponentially over distance. For the nine configurations tested, the average forces were 3,334 ± 1,239 gf at 0.1 cm, 158 ± 98 gf at 2.5 cm, and 8.7 ± 12 gf at 5 cm; the drop-off threshold was 3.64 ± 0.8 cm. The larger stacking configurations and magnets yielded up to a 592% increase in attraction force at 2.5 cm and extended the drop-off threshold distance by up to 107% over single-stack anchors. For the strongest configuration, coupling force ranged from 5,337 gf at 0.1 cm to 0 gf at 6.95 cm and yielded a drop-off threshold distance of 4.78 cm. This study suggests that the strongest configuration of currently available MAGS instruments is suitable for clinically relevant abdominal wall thicknesses. Further platform development and optimization are warranted.
Bioengineered anterior cruciate ligament
NASA Technical Reports Server (NTRS)
Martin, Ivan (Inventor); Altman, Gregory (Inventor); Kaplan, David (Inventor); Vunjak-Novakovic, Gordana (Inventor)
2001-01-01
The present invention provides a method for producing an anterior cruciate ligament ex vivo. The method comprises seeding pluripotent stem cells in a three dimensional matrix, anchoring the seeded matrix by attachment to two anchors, and culturing the cells within the matrix under conditions appropriate for cell growth and regeneration, while subjecting the matrix to one or more mechanical forces via movement of one or both of the attached anchors. Bone marrow stromal cells are preferably used as the pluripotent cells in the method. Suitable matrix materials are materials to which cells can adhere, such as a gel made from collagen type I. Suitable anchor materials are materials to which the matrix can attach, such as Goinopra coral and also demineralized bone. Optimally, the mechanical forces to which the matrix is subjected mimic mechanical stimuli experienced by an anterior cruciate ligament in vivo. This is accomplished by delivering the appropriate combination of tension, compression, torsion, and shear, to the matrix. The bioengineered ligament which is produced by this method is characterized by a cellular orientation and/or matrix crimp pattern in the direction of the applied mechanical forces, and also by the production of collagen type I, collagen type III, and fibronectin proteins along the axis of mechanical load produced by the mechanical forces. Optimally, the ligament produced has fiber bundles which are arranged into a helical organization. The method for producing an anterior cruciate ligament can be adapted to produce a wide range of tissue types ex vivo by adapting the anchor size and attachment sites to reflect the size of the specific type of tissue to be produced, and also adapting the specific combination of forces applied, to mimic the mechanical stimuli experienced in vivo by the specific type of tissue to be produced. The methods of the present invention can be further modified to incorporate other stimuli experienced in vivo by the particular developing tissue, some examples of the stimuli being chemical stimuli, and electro-magnetic stimuli. Some examples of tissue which can be produced include other ligaments in the body (hand, wrist, elbow, knee), tendon, cartilage, bone, muscle, and blood vessels.
NASA Astrophysics Data System (ADS)
Baek, Sang-In; Kim, Sung-Jo; Kim, Jong-Hyun
2015-09-01
Although the homeotropic alignment of liquid crystals is widely used in LCD TVs, no easy method exists to measure its anchoring coefficient. In this study, we propose an easy and convenient measurement technique in which a polarizing optical microscope is used in the reflective mode with an objective lens having a low depth of focus. All measurements focus on the reflection of light near the interface between the liquid crystal and alignment layer. The change in the reflected light is measured by applying an electric field. We model the response of the director of the liquid crystal to the electric field and, thus, the change in reflectance. By adjusting the extrapolation length in the calculation, we match the experimental and calculated results and obtain the anchoring coefficient. In our experiment, the extrapolation lengths were 0.31 ± 0.04 μm, 0.32 ± 0.08 μm, and 0.23 ± 0.05 μm for lecithin, AL-64168, and SE-5662, respectively.
Abuillan, Wasim; Vorobiev, Alexei; Hartel, Andreas; Jones, Nicola G; Engstler, Markus; Tanaka, Motomu
2012-11-28
As a physical model of the surface of cells coated with densely packed, non-crystalline proteins coupled to lipid anchors, we functionalized the surface of phospholipid membranes by coupling of neutravidin to biotinylated lipid anchors. After the characterization of fine structures perpendicular to the plane of membrane using specular X-ray reflectivity, the same membrane was characterized by grazing incidence small angle X-ray scattering (GISAXS). Within the framework of distorted wave Born approximation and two-dimensional Percus-Yevick function, we can analyze the form and structure factors of the non-crystalline, membrane-anchored proteins for the first time. As a new experimental technique to quantify the surface density of proteins on the membrane surface, we utilized grazing incidence X-ray fluorescence (GIXF). Here, the mean intermolecular distance between proteins from the sulfur peak intensities can be calculated by applying Abelé's matrix formalism. The characteristic correlation distance between non-crystalline neutravidin obtained by the GISAXS analysis agrees well with the intermolecular distance calculated by GIXF, suggesting a large potential of the combination of GISAXS and GIXF in probing the lateral density and correlation of non-crystalline proteins displayed on the membrane surface.
Novel cancer vaccines prepared by anchoring cytokines to tumor cells avoiding gene transfection
NASA Astrophysics Data System (ADS)
Nizard, Philippe; Gross, David-Alexandre; Chenal, Alexandre; Beaumelle, Bruno; Kosmatopoulos, Konstadinos; Gillet, Daniel
2002-06-01
Cytokines have a strong potential for triggering anticancer immunity if released in the tumor microenvironment. Successful vaccines have been engineered using tumor cells genetically modified to secrete the cytokines. Unfortunately, this approach remains difficult and hazardous to perform in the clinic. We describe a new way of combining cytokines with tumor cells to prepare anticancer vaccines. This consists in anchoring recombinant cytokines to the membrane of killed tumor cells. Attachment is mediated by a fragment of diphtheria toxin (T) genetically connected to the cytokine. It is triggered by an acid pH pulse. The method was applied to IL-2, a potent anti-tumor cytokine. IL-2 anchored to the surface of tumor cells by the T anchor retained its IL-2 activity and remained exposed several days. Interestingly, vaccination of mice with these modified tumor cells induced a protective anti-tumor immunity mediated by tumor-specific cytotoxic T lymphocytes. This procedure presents several advantages as compared to the conventional approaches based on the transfection of tumor cells with cytokine genes. It does not require the culture of tumor cells from the patients and eliminates the safety problems connected with viral vectors while allowing the control of the amount of cytokines delivered with the vaccine.
Gonzales, Matthew J; Vincent, Kevin P; Rappel, Wouter-Jan; Narayan, Sanjiv M; McCulloch, Andrew D
2014-11-01
The aim of this study was to investigate structural contributions to the maintenance of rotors in human atrial fibrillation (AF) and possible mechanisms of termination. A three-dimensional human biatrial finite element model based on patient-derived computed tomography and arrhythmia observed at electrophysiology study was used to study AF. With normal physiological electrical conductivity and effective refractory periods (ERPs), wave break failed to sustain reentrant activity or electrical rotors. With depressed excitability, decreased conduction anisotropy, and shorter ERP characteristic of AF, reentrant rotors were readily maintained. Rotors were transiently or permanently trapped by fibre discontinuities on the lateral wall of the right atrium near the tricuspid valve orifice and adjacent to the crista terminalis, both known sites of right atrial arrhythmias. Modelling inexcitable regions near the rotor tip to simulate fibrosis anchored the rotors, converting the arrhythmia to macro-reentry. Accordingly, increasing the spatial core of inexcitable tissue decreased the frequency of rotation, widened the excitable gap, and enabled an external wave to impinge on the rotor core and displace the source. These model findings highlight the importance of structural features in rotor dynamics and suggest that regions of fibrosis may anchor fibrillatory rotors. Increasing extent of fibrosis and scar may eventually convert fibrillation to excitable gap reentry. Such macro-reentry can then be eliminated by extending the obstacle or by external stimuli that penetrate the excitable gap. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
CRYogenic Orbital TEstbed Ground Test Article Thermal Analysis
NASA Technical Reports Server (NTRS)
Piryk, David; Schallhorn, Paul; Walls, Laurie; Stopnitzky, Benny; Rhys, Noah; Wollen, Mark
2012-01-01
The purpose of this study was to anchor thermal and fluid system models to CRYOTE ground test data. The CRYOTE ground test artide was jointly developed by Innovative Engineering Solutions, United Launch Alliance and NASA KSC. The test article was constructed out of a titanium alloy tank, Sapphire 77 composite skin (similar to G10), an external secondary payload adapter ring, thermal vent system, multi layer insulation and various data acquisition instrumentation. In efforts to understand heat loads throughout this system, the GTA (filled with liquid nitrogen for safety purposes) was subjected to a series of tests in a vacuum chamber at Marshall Space Flight Center. By anchoring analytical models against test data, higher fidelity thermal environment predictions can be made for future flight articles which would eventually demonstrate critical cryogenic fluid management technologies such as system chilldown, transfer, pressure control and long term storage. Significant factors that influenced heat loads included radiative environments, multi-layer insulation performance, tank fill levels and pressures and even contact conductance coefficients. This report demonstrates how analytical thermal/fluid networks were established and includes supporting rationale for specific thermal responses.
Rosa, Francisco; Coutinho, Miguel Bebiano; Ferreira, João Pinto; Sousa, Cecilia Almeida
2016-01-01
The aim of this study was to assess the main ear malformations, hearing loss and auditory rehabilitation in children with Treacher Collins syndrome. We performed a retrospective study of 9 children with Treacher Collins syndrome treated in a central hospital between January 2003 and January 2013. This study showed a high incidence of malformations of the outer and middle ear, such as microtia, atresia or stenosis of the external auditory canal, hypoplastic middle ear cavity, dysmorphic or missing ossicular chain. Most patients had bilateral hearing loss of moderate or high degree. In the individuals studied, there was functional improvement in patients with bone-anchored hearing aids in relation to conventional hearing aids by bone conduction. Treacher Collins syndrome is characterized by bilateral malformations of the outer and middle ear. Hearing rehabilitation in these children is of utmost importance, and bone-anchored hearing aids is the method of choice. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Lin, Xiaoxiao; Ye, Min; Li, Yuping
2018-01-01
Upper tracheal stenosis is considered as a potentially life-threatening condition. Silicone stenting is an attractive treatment option for patients with upper tracheal stenosis. However, its use has been compromised by a major complication, stent migration. In the report, we introduced a novel external fixation of silicone stent which only needed one puncture site and involved a silicon chip as an anchoring device. All equipment and materials including the silicon chip were available in routine bronchoscopy suite. The method had been successfully performed in three patients with upper tracheal stenosis at our institution. And the patients were monitored for over 20 months after the intervention, and no spontaneous stent migration occurred. Therefore, we believe this is a simple and reliable approach for improving the outcome of silicone stenting in patients with upper tracheal stenosis and should be introduced in clinical practice.
Constructive and problem-based learning using blended learning anchored instruction approaches
NASA Astrophysics Data System (ADS)
Mayer, M.
2012-04-01
Based on an anchored instruction approach, an enriched blended learning lecture course ("Introduction into GNSS positioning") was established in order to enable constructive and problem-based learning. The lecture course "Introduction into GNSS positioning" is a compulsory part of the Bachelor study course "Geodesy and Geoinformatics" and also a supplementary module of the Bachelor study course "Geophysics". Within the lecture course, basic knowledge and basic principles of Global Navigation Satellite Systems, like GPS, are imparted. The presented higher education technique "anchored instruction" uses a real and up-to-date and therefore authentic scientific paper dealing with a recent large-scale geodetic project (Fehmarn Belt Fixed Link) in order to introduce the topic of GNSS-based positioning to the students. In the beginning of the semester, the students have to read the paper individually and carefully. This enables them to realize a lot of not-known GNSS-related facts. Therefore, questions can be formulated focusing on new, unclear or not-understood aspects of the paper. The lecture course deals with these questions, in order to answer them throughout the semester. During the lecture course this paper is referred, e.g., in the middle of the semester, the paper has to be read again in order to check which questions have been answered; in addition, new question arise. At the end of the lecture course, the author of the scientific paper gave a concluding lecture. The framing anchor technique enables the students to anchor their GNSS knowledge. The presented case study uses a teaching resp. learning setting consisting of classroom lectures (given by teachers and learners), practical trainings (e.g., field exercises, students select topics individually), and online lectures (learning management system ILIAS is used as data, result, and asynchronous communication platform). The implementation and the elements of the anchoring technique, which enables student-centered, cooperative, and individual learning, are going to be discussed in detail. A special focus of the presentation is on work assignments, time schedule, and work load. The anchor technique is applied within a blended learning teaching concept, therefore the role of the learning management system ILIAS will be treated as well.
Comparison of the effects and performance of four types of radiotransmitters for use with scoters
Iverson, S.A.; Boyd, W.S.; Esler, Daniel N.; Mulcahy, D.M.; Bowman, Timothy D.
2006-01-01
Radiotransmitters are widely used in wildlife ecology, often providing data that cannot be collected using other methods. However, negative effects have been associated with the use of transmitters for some species. We evaluated the effects and performance of 4 radiotransmitter types for use with surf and white-winged scoters (Melanitta perspicillata and M. fusca): COEXT-coelomically implanted transmitters with external antennas, COINT-coelomically implanted transmitters with internal antennas, SUBCU-subcutaneous implants with external antennas, and PRONG-external mounts, attached by a subcutaneous anchor and glue, with external antennas. Survival was not related to radiotransmitter type during the immediate (14-d) post-release period when most deaths (8 of 12) occurred. Rates of signal disappearance (transmitters ceased to be detected in the study area) and transmitter shedding (transmitters recovered without sign of predation) were similar among types over 30- and 60-day intervals; however, higher proportions of dorsally mounted radiotransmitters (SUBCU, PRONG) disappeared or were shed over course of the full 100-day monitoring period used in this study. All 4 radiotransmitter types allowed for relatively accurate location estimates, with linear error estimates (distance between actual and estimated location) averaging 2 months in duration and for satellite telemetry studies of scoters. However, SUBCU and PRONG are recommended as cost-effective alternatives in shorter-duration radiotelemetry studies.
Effects of accuracy motivation and anchoring on metacomprehension judgment and accuracy.
Zhao, Qin
2012-01-01
The current research investigates how accuracy motivation impacts anchoring and adjustment in metacomprehension judgment and how accuracy motivation and anchoring affect metacomprehension accuracy. Participants were randomly assigned to one of six conditions produced by the between-subjects factorial design involving accuracy motivation (incentive or no) and peer performance anchor (95%, 55%, or no). Two studies showed that accuracy motivation did not impact anchoring bias, but the adjustment-from-anchor process occurred. Accuracy incentive increased anchor-judgment gap for the 95% anchor but not for the 55% anchor, which induced less certainty about the direction of adjustment. The findings offer support to the integrative theory of anchoring. Additionally, the two studies revealed a "power struggle" between accuracy motivation and anchoring in influencing metacomprehension accuracy. Accuracy motivation could improve metacomprehension accuracy in spite of anchoring effect, but if anchoring effect is too strong, it could overpower the motivation effect. The implications of the findings were discussed.
On the Theory of Ground Anchors
1975-01-01
Reinart 46 American Electric Power Service anchor tests 47 Expandable land anchor 51 Anchorages in frozen ground 52 Foundation anchoring in thawed ground...Idealized configuration of Malone anchor 48 54. Standard grillage anchor and pyramid grillage anchor tested by the American Electric Power Service...Corporation 49 55. Configuration of bell anchors tested by the American Electric Power Service Corporation 50 56. Configuration of steel grillage - screw
Tensegrity and mechanoregulation: from skeleton to cytoskeleton
NASA Technical Reports Server (NTRS)
Chen, C. S.; Ingber, D. E.
1999-01-01
OBJECTIVE: To elucidate how mechanical stresses that are applied to the whole organism are transmitted to individual cells and transduced into a biochemical response. DESIGN: In this article, we describe fundamental design principles that are used to stabilize the musculoskeletal system at many different size scales and show that these design features are embodied in one particular form of architecture that is known as tensegrity. RESULTS: Tensegrity structures are characterized by use of continuous tension and local compression; architecture, prestress (internal stress prior to application of external force), and triangulation play the most critical roles in terms of determining their mechanical stability. In living organisms, use of a hierarchy of tensegrity networks both optimizes structural efficiency and provides a mechanism to mechanically couple the parts with the whole: mechanical stresses applied at the macroscale result in structural rearrangements at the cell and molecular level. CONCLUSION: Due to use of tensegrity architecture, mechanical stress is concentrated and focused on signal transducing molecules that physically associate with cell surface molecules that anchor cells to extracellular matrix, such as integrins, and with load-bearing elements within the internal cytoskeleton and nucleus. Mechanochemical transduction may then proceed through local stress-dependent changes in molecular mechanics, thermodynamics, and kinetics within the cell. In this manner, the entire cellular response to stress may be orchestrated and tuned by altering the prestress in the cell, just as changing muscular tone can alter mechanical stability and structural coordination throughout the whole musculoskeletal system.
Ground anchors and anchored systems
DOT National Transportation Integrated Search
1999-06-01
This document presents state-of-the-practice information on the design and installation of cement-grouted ground anchors and anchored systems for highway applications. The anchored systems discussed include flexible anchored walls, slopes supported u...
Anchoring Revisited: The Role of the Comparative Question
Grau, Ina; Bohner, Gerd
2014-01-01
When people estimate a numeric value after judging whether it is larger or smaller than a high or low anchor value (comparative question), estimates are biased in the direction of the anchor. One explanation for this anchoring effect is that people selectively access knowledge consistent with the anchor value as part of a positive test strategy. Two studies (total N = 184) supported the alternative explanation that people access knowledge consistent with their own answer to the comparative question. Specifically, anchoring effects emerged when the answer to the comparative question was unexpected (lower than the low anchor or higher than the high anchor). For expected answers (lower than the high anchor or higher than the low anchor), however, anchoring effects were attenuated or reversed. The anchor value itself was almost never reported as an absolute estimate. PMID:24454953
Phosphonate-anchored monolayers for antibody binding to magnetic nanoparticles.
Benbenishty-Shamir, Helly; Gilert, Roni; Gotman, Irena; Gutmanas, Elazar Y; Sukenik, Chaim N
2011-10-04
Targeted delivery of magnetic iron oxide nanoparticles (IONPs) to a specific tissue can be achieved by conjugation with particular biological ligands on an appropriately functionalized IONP surface. To take best advantage of the unique magnetic properties of IONPs and to maximize their blood half-life, thin, strongly bonded, functionalized coatings are required. The work reported herein demonstrates the successful application of phosphonate-anchored self-assembled monolayers (SAMs) as ultrathin coatings for such particles. It also describes a new chemical approach to the anchoring of antibodies on the surface of SAM-coated IONPs (using nucleophilic aromatic substitution). This anchoring strategy results in stable, nonhydrolyzable, covalent attachment and allows the reactivity of the particles toward antibody binding to be activated in situ, such that prior to the activation the modified surface is stable for long-term storage. While the SAMs do not have the well-packed crystallinity of other such monolayers, their structure was studied using smooth model substrates based on an iron oxide layer on a double-side polished silicon wafer. In this way, atomic force microscopy, ellipsometry, and contact angle goniometry (tools that could not be applied to the nanoparticles' surfaces) could contribute to the determination of their monomolecular thickness and uniformity. Finally, the successful conjugation of IgG antibodies to the SAM-coated IONPs such that the antibodies retain their biological activity is verified by their complexation to a secondary fluorescent antibody. © 2011 American Chemical Society
Marketing Strategies for Visibility
ERIC Educational Resources Information Center
Ashcroft, Linda
2010-01-01
Any organization must build a good reputation and image in order to "anchor" its relevance and indispensability in the minds of a wide variety of audiences. Many commercial organizations maximize opportunities to raise favourable awareness about what they do--and their techniques and approaches can be applied to libraries. Examples from…
Stretching of a polymer chain anchored to a surface: the massive field theory approach
NASA Astrophysics Data System (ADS)
Usatenko, Zoryana
2014-09-01
Taking into account the well-known correspondence between the field theoretical φ4 O(n)-vector model in the limit n → 0 and the behaviour of long-flexible polymer chains, the investigation of stretching of an ideal and a real polymer chain with excluded volume interactions in a good solvent anchored to repulsive and inert surfaces is performed. The calculations of the average stretching force which arises when the free end of a polymer chain moves away from a repulsive or inert surface are performed up to one-loop order of the massive field theory approach in fixed space dimensions d = 3. The analysis of the obtained results indicates that the average stretching force for a real polymer chain anchored to a repulsive surface demonstrates different behaviour for the cases \\tilde{z}\\ll1 and \\tilde{z}\\gg1 , where \\tilde{z}=z^\\prime/Rz . Besides, the results obtained in the framework of the massive field theory approach are in good agreement with previous theoretical results for an ideal polymer chain and results of a density functional theory approach for the region of small applied forces when deformation of a polymer chain in the direction of the applied force is not bigger than the linear extension of a polymer chain in this direction. The better agreement between these two methods is observed in the case where the number of monomers increases and the polymer chain becomes longer.
Waterhammer Transient Simulation and Model Anchoring for the Robotic Lunar Lander Propulsion System
NASA Technical Reports Server (NTRS)
Stein, William B.; Trinh, Huu P.; Reynolds, Michael E.; Sharp, David J.
2011-01-01
Waterhammer transients have the potential to adversely impact propulsion system design if not properly addressed. Waterhammer can potentially lead to system plumbing, and component damage. Multi-thruster propulsion systems also develop constructive/destructive wave interference which becomes difficult to predict without detailed models. Therefore, it is important to sufficiently characterize propulsion system waterhammer in order to develop a robust design with minimal impact to other systems. A risk reduction activity was performed at Marshall Space Flight Center to develop a tool for estimating waterhammer through the use of anchored simulation for the Robotic Lunar Lander (RLL) propulsion system design. Testing was performed to simulate waterhammer surges due to rapid valve closure and consisted of twenty-two series of waterhammer tests, resulting in more than 300 valve actuations. These tests were performed using different valve actuation schemes and three system pressures. Data from the valve characterization tests were used to anchor the models that employed MSCSoftware.EASY5 v.2010 to model transient fluid phenomena by using transient forms of mass and energy conservation. The anchoring process was performed by comparing initial model results to experimental data and then iterating the model input to match the simulation results with the experimental data. The models provide good correlation with experimental results, supporting the use of EASY5 as a tool to model fluid transients and provide a baseline for future RLL system modeling. This paper addresses tasks performed during the waterhammer risk reduction activity for the RLL propulsion system. The problem of waterhammer simulation anchoring as applied to the RLL system is discussed with results from the corresponding experimental valve tests. Important factors for waterhammer mitigation are discussed along with potential design impacts to the RLL propulsion system.
Stress Transfer and Structural Failure of Bilayered Material Systems
NASA Astrophysics Data System (ADS)
Prieto-Munoz, Pablo Arthur
Bilayered material systems are common in naturally formed or artificially engineered structures. Understanding how loads transfer within these structural systems is necessary to predict failure and develop effective designs. Existing methods for evaluating the stress transfer in bilayered materials are limited to overly simplified models or require experimental calibration. As a result, these methods have failed to accurately account for such structural failures as the creep induced roofing panel collapse of Boston's I-90 connector tunnel, which was supported by adhesive anchors. The one-dimensional stress analyses currently used for adhesive anchor design cannot account for viscoelastic creep failure, and consequently results in dangerously under-designed structural systems. In this dissertation, a method for determining the two-dimensional stress and displacement fields for a generalized bilayered material system is developed, and proposes a closed-form analytical solution. A general linear-elastic solution is first proposed by decoupling the elastic governing equations from one another through the so-called plane assumption. Based on this general solution, an axisymmetric problem and a plane strain problem are formulated. These are applied to common bilayered material systems such as: (1) concrete adhesive anchors, (2) material coatings, (3) asphalt pavements, and (4) layered sedimentary rocks. The stress and displacement fields determined by this analytical analysis are validated through the use of finite element models. Through the correspondence principle, the linear-elastic solution is extended to consider time-dependent viscoelastic material properties, thus facilitating the analysis of adhesive anchors and asphalt pavements while incorporating their viscoelastic material behavior. Furthermore, the elastic stress analysis can explain the fracturing phenomenon of material coatings, pavements, and layered rocks, successfully predicting their fracture saturation ratio---which is the ratio of fracture spacing to the thickness of the weak layer where an increase in load will not cause any new fractures to form. Moreover, these specific material systems are looked at in the context of existing and novel experimental results, further demonstrating the advantage of the stress transfer analysis proposed. This research provides a closed-form stress solution for various structural systems that is applied to different failure analyses. The versatility of this method is in the flexibility and the ease upon which the stress and displacement field results can be applied to existing stress- or displacement-based structural failure criteria. As presented, this analysis can be directly used to: (1) design adhesive anchoring systems for long-term creep loading, (2) evaluate the fracture mechanics behind bilayered material coatings and pavement overlay systems, and (3) determine the fracture spacing to layer thickness ratio of layered sedimentary rocks. As is shown in the four material systems presented, this general solution has far reaching applications in facilitating design and analysis of typical bilayered structural systems.
Motivated Use of Numerical Anchors for Judgments Relevant to the Self.
Joel, Samantha; Spielmann, Stephanie S; MacDonald, Geoff
2017-07-01
The anchoring effect has been replicated so extensively that it is generally thought to be ubiquitous. However, anchoring has primarily been tested in domains in which people are motivated to reach accurate conclusions rather than biased conclusions. Is the anchoring effect robust even when the anchors are threatening? In three studies, participants made a series of probability judgments about their own futures paired with either optimistic anchors (e.g., "Do you think that the chances that your current relationship will last a lifetime are more or less than 95%?"), pessimistic anchors (e.g., "more or less than 10%?"), or no anchors. A fourth study experimentally manipulated motivation to ignore the anchor with financial incentives. Across studies, anchors that implied high probabilities of unwanted events occurring were ineffective. Together, these studies suggest that anchoring has an important boundary condition: Personally threatening anchors are ignored as a result of motivated reasoning processes.
The Monterey Ocean Observing System Development Program
NASA Astrophysics Data System (ADS)
Chaffey, M.; Graybeal, J. B.; O'Reilly, T.; Ryan, J.
2004-12-01
The Monterey Bay Aquarium Research Institute (MBARI) has a major development program underway to design, build, test and apply technology suitable to deep ocean observatories. The Monterey Ocean Observing System (MOOS) program is designed to form a large-scale instrument network that provides generic interfaces, intelligent instrument support, data archiving and near-real-time interaction for observatory experiments. The MOOS mooring system is designed as a portable surface mooring based seafloor observatory that provides data and power connections to both seafloor and ocean surface instruments through a specialty anchor cable. The surface mooring collects solar and wind energy for powering instruments and transmits data to shore-side researchers using a satellite communications modem. The use of a high modulus anchor cable to reach seafloor instrument networks is a high-risk development effort that is critical for the overall success of the portable observatory concept. An aggressive field test program off the California coast is underway to improve anchor cable constructions as well as end-to-end test overall system design. The overall MOOS observatory systems view is presented and the results of our field tests completed to date are summarized.
Lattice Boltzmann simulation of asymmetric flow in nematic liquid crystals with finite anchoring
NASA Astrophysics Data System (ADS)
Zhang, Rui; Roberts, Tyler; Aranson, Igor S.; de Pablo, Juan J.
2016-02-01
Liquid crystals (LCs) display many of the flow characteristics of liquids but exhibit long range orientational order. In the nematic phase, the coupling of structure and flow leads to complex hydrodynamic effects that remain to be fully elucidated. Here, we consider the hydrodynamics of a nematic LC in a hybrid cell, where opposite walls have conflicting anchoring boundary conditions, and we employ a 3D lattice Boltzmann method to simulate the time-dependent flow patterns that can arise. Due to the symmetry breaking of the director field within the hybrid cell, we observe that at low to moderate shear rates, the volumetric flow rate under Couette and Poiseuille flows is different for opposite flow directions. At high shear rates, the director field may undergo a topological transition which leads to symmetric flows. By applying an oscillatory pressure gradient to the channel, a net volumetric flow rate is found to depend on the magnitude and frequency of the oscillation, as well as the anchoring strength. Taken together, our findings suggest several intriguing new applications for LCs in microfluidic devices.
Meyer, Georg F.; Shao, Fei; White, Mark D.; Hopkins, Carl; Robotham, Antony J.
2013-01-01
Externally generated visual motion signals can cause the illusion of self-motion in space (vection) and corresponding visually evoked postural responses (VEPR). These VEPRs are not simple responses to optokinetic stimulation, but are modulated by the configuration of the environment. The aim of this paper is to explore what factors modulate VEPRs in a high quality virtual reality (VR) environment where real and virtual foreground objects served as static visual, auditory and haptic reference points. Data from four experiments on visually evoked postural responses show that: 1) visually evoked postural sway in the lateral direction is modulated by the presence of static anchor points that can be haptic, visual and auditory reference signals; 2) real objects and their matching virtual reality representations as visual anchors have different effects on postural sway; 3) visual motion in the anterior-posterior plane induces robust postural responses that are not modulated by the presence of reference signals or the reality of objects that can serve as visual anchors in the scene. We conclude that automatic postural responses for laterally moving visual stimuli are strongly influenced by the configuration and interpretation of the environment and draw on multisensory representations. Different postural responses were observed for real and virtual visual reference objects. On the basis that automatic visually evoked postural responses in high fidelity virtual environments should mimic those seen in real situations we propose to use the observed effect as a robust objective test for presence and fidelity in VR. PMID:23840760
Minimally important difference for the Expanded Prostate Cancer Index Composite Short Form.
Skolarus, Ted A; Dunn, Rodney L; Sanda, Martin G; Chang, Peter; Greenfield, Thomas K; Litwin, Mark S; Wei, John T
2015-01-01
To establish a score threshold that constitutes a clinically relevant change for each domain of the Expanded Prostate Cancer Index Composite (EPIC) Short Form (EPIC-26). Although its use in clinical practice and clinical trials has increased worldwide, the clinical interpretation of this 26-item disease-specific patient-reported quality of life questionnaire for men with localized prostate cancer would be facilitated by characterization of score thresholds for clinically relevant change (the minimally important differences [MIDs]). We used distribution- and anchor-based approaches to establish the MID range for each EPIC-26 domain (urinary, sexual, bowel, and vitality/hormonal) based on a prospective multi-institutional cohort of 1201 men treated for prostate cancer between 2003 and 2006 and followed up for 3 years after treatment. For the anchor-based approach, we compared within-subject and between-subject score changes for each domain to an external "anchor" measure of overall cancer treatment satisfaction. We found the bowel and vitality/hormonal domains to have the lowest MID range (a 4-6 point change should be considered clinically relevant), whereas the sexual domain had the greatest MID values (10-12). Urinary incontinence appeared to have a greater MID range (6-9) than the urinary irritation/obstruction domain (5-7). Using 2 independent approaches, we established the MIDs for each EPIC-26 domain. A definition of these MID values is essential for the researcher or clinician to understand when changes in symptom burden among prostate cancer survivors are clinically relevant. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deschenes, Austin; Muneer, Sadid; Akbulut, Mustafa
Thermal assistance has been shown to significantly reduce the required operation power for spin torque transfer magnetic random access memory (STT-MRAM). Proposed heating methods include modified material stack compositions that result in increased self-heating or external heat sources. Here, we analyze the self-heating process of a standard perpendicular magnetic anisotropy STT-MRAM device through numerical simulations in order to understand the relative contributions of Joule, thermoelectric Peltier and Thomson, and tunneling junction heating. A 2D rotationally symmetric numerical model is used to solve the coupled electro-thermal equations including thermoelectric effects and heat absorbed or released at the tunneling junction. We comparemore » self-heating for different common passivation materials, positive and negative electrical current polarity, and different device thermal anchoring and boundaries resistance configurations. The variations considered are found to result in significant differences in maximum temperatures reached. Average increases of 3 K, 10 K, and 100 K for different passivation materials, positive and negative polarity, and different thermal anchoring configurations, respectively, are observed. Furthermore, the highest temperatures, up to 424 K, are obtained for silicon dioxide as the passivation material, positive polarity, and low thermal anchoring with thermal boundary resistance configurations. Interestingly it is also found that due to the tunneling heat, Peltier effect, device geometry, and numerous interfacial layers around the magnetic tunnel junction (MTJ), most of the heat is dissipated on the lower potential side of the magnetic junction. We have observed this asymmetry in heating and is important as thermally assisted switching requires heating of the free layer specifically and this will be significantly different for the two polarity operations, set and reset.« less
Analysis of ship maneuvering data from simulators
NASA Astrophysics Data System (ADS)
Frette, V.; Kleppe, G.; Christensen, K.
2011-03-01
We analyze complex manuevering histories of ships obtained from training sessions on bridge simulators. Advanced ships are used in fields like offshore oil exploration: dive support vessels, supply vessels, anchor handling vessels, tugs, cable layers, and multi-purpose vessels. Due to high demands from the operations carried out, these ships need to have very high maneuverability. This is achieved through a propulsion system with several thrusters, water jets, and rudders in addition to standard propellers. For some operations, like subsea maintenance, it is crucial that the ship accurately keeps a fixed position. Therefore, bridge systems usually incorporate equipment for Dynamic Positioning (DP). DP is a method to keep ships and semi submersible rigs in a fixed position using the propulsion systems instead of anchors. It may also be used for sailing a vessel from one position to another along a predefined route. Like an autopilot on an airplane, DP may operate without human involvement. The method relies on accurate determination of position from external reference systems like GPS, as well as a continuously adjusted mathematical model of the ship and external forces from wind, waves and currents. In a specific simulator exercise for offshore crews, a ship is to be taken up to an installation consisting of three nearby oil platforms connected by bridges (Frigg field, North Sea), where a subsea inspection is to be carried out. Due to the many degrees of freedom during maneuvering, including partly or full use of DP, the chosen routes vary significantly. In this poster we report preliminary results on representations of the complex maneuvering histories; representations that allow comparison between crew groups, and, possibly, sorting of the different strategic choices behind.
Controlling Two-dimensional Tethered Vesicle Motion Using an Electric Field
Yoshina-Ishii, Chiaki; Boxer, Steven G.
2008-01-01
We recently introduced methods to tether phospholipid vesicles or proteoliposomes onto a fluid supported lipid bilayer using DNA hybridization. These intact tethered vesicles diffuse in two dimensions parallel to the supporting membrane surface. In this paper, we report the dynamic response of individual tethered vesicles to an electric field applied parallel to the bilayer surface. Vesicles respond to the field by moving in the direction of electro-osmotic flow, and this can be used to reversibly concentrate tethered vesicles against a barrier. By adding increasing amounts of negatively charged phosphatidylserine to the supporting bilayer to increase electro-osmosis, the electrophoretic mobility of the tethered vesicles can be increased. The electro-osmotic contribution can be modeled well by a sphere connected to a cylindrical anchor in a viscous membrane with charged head groups. The electrophoretic force on the negatively charged tethered vesicles opposes the electro-osmotic force. By increasing the amount of negative charge on the tethered vesicle, drift in the direction of electro-osmotic flow can be slowed; at high negative charge on the tethered vesicle, motion can be forced in the direction of electrophoresis. The balance between these forces can be visualized on a patterned supporting bilayer containing negatively charged lipids which themselves reorganize in an externally applied electric field to create a gradient of charge within a corralled region. The charge gradient at the surface creates a gradient of electro-osmotic flow, and vesicles carrying similar amounts of negative charge can be focused to a region perpendicular to the applied field where electrophoresis is balanced by electro-osmosis, away from the corral boundary. Electric fields are effective tools to direct tethered vesicles, concentrate them and to measure the tethered vesicle’s electrostatic properties. PMID:16489833
The design and analysis of mooring system
NASA Astrophysics Data System (ADS)
Li, Yixuan
2017-05-01
In this paper, the force status and a design method of single chain mooring system for shallow sea observation network are studied. With treating the link of a chain, steel drum and steel pipe as a rigid body, the recurrence model is established by using Newton's first law and the law of Moment equilibrium theorem. Via the simplified calculation of dichotomy searching, we determine the design parameters of mooring system, such as anchor model, anchor chain length, heavy ball quality under different water flow and wind conditions. We apply MATLAB to simulate the internal steady state of the system in the fixed scheme, water depth of buoy and swimming area to meet the decision-making needs, providing an idea for the actual scheme design of mooring system.
[Dual process in large number estimation under uncertainty].
Matsumuro, Miki; Miwa, Kazuhisa; Terai, Hitoshi; Yamada, Kento
2016-08-01
According to dual process theory, there are two systems in the mind: an intuitive and automatic System 1 and a logical and effortful System 2. While many previous studies about number estimation have focused on simple heuristics and automatic processes, the deliberative System 2 process has not been sufficiently studied. This study focused on the System 2 process for large number estimation. First, we described an estimation process based on participants’ verbal reports. The task, corresponding to the problem-solving process, consisted of creating subgoals, retrieving values, and applying operations. Second, we investigated the influence of such deliberative process by System 2 on intuitive estimation by System 1, using anchoring effects. The results of the experiment showed that the System 2 process could mitigate anchoring effects.
NASA Astrophysics Data System (ADS)
He, Lijie; Langlet, Michel; Stambouli, Valerie
2017-03-01
The conformation and topological properties of DNA single strand probe molecules attached on solid surfaces are important, notably for the performances of devices such as biosensors. Commonly, the DNA probes are tethered to the surface using external linkers such as NH2. In this study, the role and influence of this amino-linker on the immobilization way and conformation of DNA probes on Ag nanoparticle surface is emphasized using Surface Enhanced Raman Spectroscopy (SERS). We compare the SERS spectra and their reproducibility in the case of two groups of DNA polybase probes which are polyA, polyC, polyT, and polyG. In the first group, the polybases exhibit an external NH2 functional linker while in the second group the polybases are NH2-free. The results show that the reproducibility of SERS spectra is enhanced in the case of the first group. It leads us to propose two models of polybase conformation on Ag surface according to the presence or the absence of the external NH2 linker. In the presence of the NH2 external linker, the latter would act as a major anchoring point. As a result, the polybases are much ordered with a less random orientation than in the case of NH2-free polybases. Consequently, in view of further in situ hybridization for biosensing applications, it is strongly recommended to use NH2 linker functionalized DNA probes.
Test Score Equating Using a Mini-Version Anchor and a Midi Anchor: A Case Study Using SAT[R] Data
ERIC Educational Resources Information Center
Liu, Jinghua; Sinharay, Sandip; Holland, Paul W.; Curley, Edward; Feigenbaum, Miriam
2011-01-01
This study explores an anchor that is different from the traditional miniature anchor in test score equating. In contrast to a traditional "mini" anchor that has the same spread of item difficulties as the tests to be equated, the studied anchor, referred to as a "midi" anchor (Sinharay & Holland), has a smaller spread of…
Use of the ROC anchor in foot and ankle surgery. A retrospective study.
Kuwada, G T
1999-05-01
A retrospective study was conducted on the use of the ROC (Radial Osteo Compression) soft-tissue anchor in foot and ankle surgery. This article describes how the anchor is deployed, problematic aspects of using the anchor, and complications and success rates associated with the anchor in ankle stabilizations, posterior tibial tendon reconstruction, peroneus brevis tendon reconstruction after fracture of the base of the fifth metatarsal, and detachment and reattachment of the Achilles tendon. The ROC anchor consists of the anchor with nonabsorbable suture attached to the shaft, the deployment handle, and drill bits. The anchor and shaft are snapped into the deployment handle and inserted into the drill hole. Compression of the trigger deploys the anchor into the hole. The ROC anchor was found to be reliable, useful, and relatively easy to deploy, with outcomes similar to those of other soft-tissue anchors.
Monogenean anchor morphometry: systematic value, phylogenetic signal, and evolution
Soo, Oi Yoon Michelle; Tan, Wooi Boon; Lim, Lee Hong Susan
2016-01-01
Background. Anchors are one of the important attachment appendages for monogenean parasites. Common descent and evolutionary processes have left their mark on anchor morphometry, in the form of patterns of shape and size variation useful for systematic and evolutionary studies. When combined with morphological and molecular data, analysis of anchor morphometry can potentially answer a wide range of biological questions. Materials and Methods. We used data from anchor morphometry, body size and morphology of 13 Ligophorus (Monogenea: Ancyrocephalidae) species infecting two marine mugilid (Teleostei: Mugilidae) fish hosts: Moolgarda buchanani (Bleeker) and Liza subviridis (Valenciennes) from Malaysia. Anchor shape and size data (n = 530) were generated using methods of geometric morphometrics. We used 28S rRNA, 18S rRNA, and ITS1 sequence data to infer a maximum likelihood phylogeny. We discriminated species using principal component and cluster analysis of shape data. Adams’s Kmult was used to detect phylogenetic signal in anchor shape. Phylogeny-correlated size and shape changes were investigated using continuous character mapping and directional statistics, respectively. We assessed morphological constraints in anchor morphometry using phylogenetic regression of anchor shape against body size and anchor size. Anchor morphological integration was studied using partial least squares method. The association between copulatory organ morphology and anchor shape and size in phylomorphospace was used to test the Rohde-Hobbs hypothesis. We created monogeneaGM, a new R package that integrates analyses of monogenean anchor geometric morphometric data with morphological and phylogenetic data. Results. We discriminated 12 of the 13 Ligophorus species using anchor shape data. Significant phylogenetic signal was detected in anchor shape. Thus, we discovered new morphological characters based on anchor shaft shape, the length between the inner root point and the outer root point, and the length between the inner root point and the dent point. The species on M. buchanani evolved larger, more robust anchors; those on L. subviridis evolved smaller, more delicate anchors. Anchor shape and size were significantly correlated, suggesting constraints in anchor evolution. Tight integration between the root and the point compartments within anchors confirms the anchor as a single, fully integrated module. The correlation between male copulatory organ morphology and size with anchor shape was consistent with predictions from the Rohde-Hobbs hypothesis. Conclusions. Monogenean anchors are tightly integrated structures, and their shape variation correlates strongly with phylogeny, thus underscoring their value for systematic and evolutionary biology studies. Our MonogeneaGM R package provides tools for researchers to mine biological insights from geometric morphometric data of speciose monogenean genera. PMID:26966649
Self-organization and stability of magnetosome chains—A simulation study
Faivre, Damien; Klumpp, Stefan
2018-01-01
Magnetotactic bacteria orient in magnetic fields with the help of their magnetosome chain, a linear structure of membrane enclosed magnetic nanoparticles (magnetosomes) anchored to a cytoskeletal filament. Here, we use simulations to study the assembly and the stability of magnetosome chains. We introduce a computational model describing the attachment of the magnetosomes to the filament and their magnetic interactions. We show that the filamentous backbone is crucial for the robust assembly of the magnetic particles into a linear chain, which in turn is key for the functionality of the chain in cellular orientation and magnetically directed swimming. In addition, we simulate the response to an external magnetic field that is rotated away from the axis of the filament, an experimental method used to probe the mechanical stability of the chain. The competition between alignment along the filament and alignment with the external fields leads to the rupture of a chain if the applied field exceeeds a threshold value. These observations are in agreement with previous experiments at the population level. Beyond that, our simulations provide a detailed picture of chain rupture at the single cell level, which is found to happen through two abrupt events, which both depend on the field strength and orientation. The re-formation of the chain structure after such rupture is found to be strongly sped up in the presence of a magnetic field parallel to the filament, an observation that may also be of interest for the design of self-healing materials. Our simulations underline the dynamic nature of the magnetosome chain. More generally, they show the rich complexity of self-assembly in systems with competing driving forces for alignment. PMID:29315342
Precision of the anchor influences the amount of adjustment.
Janiszewski, Chris; Uy, Dan
2008-02-01
The anchoring-and-adjustment heuristic has been used to account for a wide variety of numerical judgments. Five studies show that adjustment away from a numerical anchor is smaller if the anchor is precise than if it is rounded. Evidence suggests that precise anchors, compared with rounded anchors, are represented on a subjective scale with a finer resolution. If adjustment consists of a series of iterative mental movements along a subjective scale, then an adjustment from a precise anchor should result in a smaller overall correction than an adjustment from a rounded anchor.
Aquarium Portal Technique for PASTA Lesion Repair.
Meyer, Dominik C; Gerber, Christian; Familiari, Filippo
2017-10-01
The simultaneous arthroscopic exposure of the subacromial and intra-articular space of the shoulder is challenging in the presence of only partial-thickness rotator cuff tears. We present our experience and method of entering the joint through the opened rotator cuff interval from an anterosuperior portal between the coracoid process and anterior acromion. With moderate (approximately 30°) abduction and external rotation, the rotator interval opens readily, offering a view with the camera toward the anterior edge of the supraspinatus tendon. An anterior view on the anterior leading edge of the supraspinatus tendon is obtained, showing the subacromial space above and the glenohumeral space below the tendon, similar to the view in an aquarium. The rotator cuff can be elevated using a rod inserted intra-articularly from posterior, whereas anchors and other instruments may be inserted from lateral. This approach offers the advantages of full exposure of the posterior undersurface of the rotator cuff insertion; a convenient approximately 90° angle between the camera and instruments; and no need to change portals for anchor placement, tendon stitching, or suture handling. The objective of this Technical Note is to describe our arthroscopic repair approach (aquarium technique) to PASTA (partial articular supraspinatus tendon avulsion) lesions.
NASA Astrophysics Data System (ADS)
Zachary, Wayne; Eggleston, Robert; Donmoyer, Jason; Schremmer, Serge
2003-09-01
Decision-making is strongly shaped and influenced by the work context in which decisions are embedded. This suggests that decision support needs to be anchored by a model (implicit or explicit) of the work process, in contrast to traditional approaches that anchor decision support to either context free decision models (e.g., utility theory) or to detailed models of the external (e.g., battlespace) environment. An architecture for cognitively-based, work centered decision support called the Work-centered Informediary Layer (WIL) is presented. WIL separates decision support into three overall processes that build and dynamically maintain an explicit context model, use the context model to identify opportunities for decision support and tailor generic decision-support strategies to the current context and offer them to the system-user/decision-maker. The generic decision support strategies include such things as activity/attention aiding, decision process structuring, work performance support (selective, contextual automation), explanation/ elaboration, infosphere data retrieval, and what if/action-projection and visualization. A WIL-based application is a work-centered decision support layer that provides active support without intent inferencing, and that is cognitively based without requiring classical cognitive task analyses. Example WIL applications are detailed and discussed.
Frequency sensitive mechanism in low-intensity ultrasound enhanced bioeffects
Chama, Abdoulkadri; Subramanian, Anuradha; Viljoen, Hendrik J.
2017-01-01
This study presents two novel theoretical models to elucidate frequency sensitive nuclear mechanisms in low-intensity ultrasound enhanced bioeffects. In contrast to the typical 1.5 MHz pulsed ultrasound regime, our group previously experimentally confirmed that ultrasound stimulation of anchored chondrocytes at resonant frequency maximized gene expression of load inducible genes which are regulatory markers for cellular response to external stimuli. However, ERK phosphorylation displayed no frequency dependency, suggesting that the biochemical mechanisms involved in enhanced gene expression is downstream of ERK phosphorylation. To elucidate such underlying mechanisms, this study presents a theoretical model of an anchored cell, representing an in vitro chondrocyte, in an ultrasound field. The model results showed that the mechanical energy storage is maximized at the chondrocyte’s resonant frequency and the energy density in the nucleus is almost twice as high as in the cytoplasm. Next, a mechanochemical model was developed to link the mechanical stimulation of ultrasound and the increased mechanical energy density in the nucleus to the downstream targets of the ERK pathway. This study showed for the first time that ultrasound stimulation induces frequency dependent gene expression as a result of altered rates of transcription factors binding to chromatin. PMID:28763448
ERIC Educational Resources Information Center
Liu, Jinghua; Sinharay, Sandip; Holland, Paul; Feigenbaum, Miriam; Curley, Edward
2011-01-01
Two different types of anchors are investigated in this study: a mini-version anchor and an anchor that has a less spread of difficulty than the tests to be equated. The latter is referred to as a midi anchor. The impact of these two different types of anchors on observed score equating are evaluated and compared with respect to systematic error…
Anchoring in Numeric Judgments of Visual Stimuli
Langeborg, Linda; Eriksson, Mårten
2016-01-01
This article investigates effects of anchoring in age estimation and estimation of quantities, two tasks which to different extents are based on visual stimuli. The results are compared to anchoring in answers to classic general knowledge questions that rely on semantic knowledge. Cognitive load was manipulated to explore possible differences between domains. Effects of source credibility, manipulated by differing instructions regarding the selection of anchor values (no information regarding anchor selection, information that the anchors are randomly generated or information that the anchors are answers from an expert) on anchoring were also investigated. Effects of anchoring were large for all types of judgments but were not affected by cognitive load or by source credibility in either one of the researched domains. A main effect of cognitive load on quantity estimations and main effects of source credibility in the two visually based domains indicate that the manipulations were efficient. Implications for theoretical explanations of anchoring are discussed. In particular, because anchoring did not interact with cognitive load, the results imply that the process behind anchoring in visual tasks is predominantly automatic and unconscious. PMID:26941684
Method and apparatus for production of subsea hydrocarbon formations
Blandford, Joseph W.
1995-01-01
A system for controlling, separating, processing and exporting well fluids produced from subsea hydrocarbon formations is disclosed. The subsea well tender system includes a surface buoy supporting one or more decks above the water surface for accommodating equipment to process oil, gas and water recovered from the subsea hydrocarbon formation. The surface buoy includes a surface-piercing central flotation column connected to one or more external floatation tanks located below the water surface. The surface buoy is secured to the seabed by one or more tendons which are anchored to a foundation with piles imbedded in the seabed. The system accommodates multiple versions on the surface buoy configuration.
Curvature by design and on demand in liquid crystal elastomers
NASA Astrophysics Data System (ADS)
Kowalski, B. A.; Mostajeran, C.; Godman, N. P.; Warner, M.; White, T. J.
2018-01-01
The shape of liquid crystalline elastomers (LCEs) with spatial variation in the director orientation can be transformed by exposure to a stimulus. Here, informed by previously reported analytical treatments, we prepare complex spiral patterns imprinted into LCEs and quantify the resulting shape transformation. Quantification of the stimuli-induced shapes reveals good agreement between predicted and experimentally observed curvatures. We conclude this communication by reporting a design strategy to allow LCE films to be anchored at their external boundaries onto rigid substrates without incurring internal, mechanical-mismatch stresses upon actuation, a critical advance to the realization of shape transformation of LCEs in practical device applications.
Jacobson, J I; Yamanashi, W S
1995-04-01
The recent clinical studies describing the treatment of some neurological disorders with an externally applied pico Tesla (10(-12) Tesla, or 10(-8) gauss) magnetic field are considered from a physical view point. An equation relating the intrinsic (or rest) energy of a charged particle of mass m with its energy of interaction in an externally applied magnetic field B is presented. The equation represents an initial basic physical interaction as a part of a more complex biological mechanism to explain the therapeutic effects of externally applied magnetic fields in these and other neurologic disorders.
Jacobson, J I; Yamanashi, W S
1995-06-01
The clinical studies describing the treatment of some neurological disorders with an externally applied pico Tesla (10R Tesla, or 10(-8) gauss) magnetic field are considered from a physical view point. An equation relating the intrinsic or "rest" energy of a charged particle of mass with its energy of interaction in an externally applied magnetic field B is presented. The equation is proposed to represent an initial basic physical interaction as a part of a more complex biological mechanism to explain the therapeutic effects of externally applied magnetic fields in these and other neurologic disorders.
Blind-Anchor-Nut-Installation Fixture (BANIF)
NASA Technical Reports Server (NTRS)
Willey, Norman F., Jr.; Linker, James F.
1994-01-01
Blind-anchor-nut-installation fixture, BANIF, developed for replacing or installing anchor nuts in blind holes or other inaccessible places. Attachment of anchor nut to BANIF enables placement of anchor nut on blind side of component.
Maiwald, Christian; Arndt, Anton; Nester, Chris; Jones, Richard; Lundberg, Arne; Wolf, Peter
2017-02-01
Bone anchored markers using intracortical bone pins are one of the few available methods for analyzing skeletal motion during human gait in-vivo without errors induced by soft tissue artifacts. However, bone anchored markers require local anesthesia and may alter the motor control and motor output during gait. The purpose of this study was to examine the effect of local anesthesia and the use of bone anchored markers on typical gait analysis variables. Five subjects were analyzed in two different gait analysis sessions. In the first session, a protocol with skin markers was used. In the second session, bone anchored markers were added after local anesthesia was applied. For both sessions, three dimensional infrared kinematics of the calcaneus and tibia segments, ground reaction forces, and plantar pressure data were collected. 95% confidence intervals and boxplots were used to compare protocols and assess the data distribution and data variability for each subject. Although considerable variation was found between subjects, within-subject comparison of the two protocols revealed non-systematic effects on the target variables. Two of the five subjects walked at reduced gait speed during the bone pin session, which explained the between-session differences found in kinetic and kinematic variables. The remaining three subjects did not systematically alter their gait pattern between the two sessions. Results support the hypothesis that local anesthesia and the presence of bone pins still allow a valid gait pattern to be analyzed. Copyright © 2016 Elsevier B.V. All rights reserved.
Constrained Active Learning for Anchor Link Prediction Across Multiple Heterogeneous Social Networks
Zhu, Junxing; Zhang, Jiawei; Wu, Quanyuan; Jia, Yan; Zhou, Bin; Wei, Xiaokai; Yu, Philip S.
2017-01-01
Nowadays, people are usually involved in multiple heterogeneous social networks simultaneously. Discovering the anchor links between the accounts owned by the same users across different social networks is crucial for many important inter-network applications, e.g., cross-network link transfer and cross-network recommendation. Many different supervised models have been proposed to predict anchor links so far, but they are effective only when the labeled anchor links are abundant. However, in real scenarios, such a requirement can hardly be met and most anchor links are unlabeled, since manually labeling the inter-network anchor links is quite costly and tedious. To overcome such a problem and utilize the numerous unlabeled anchor links in model building, in this paper, we introduce the active learning based anchor link prediction problem. Different from the traditional active learning problems, due to the one-to-one constraint on anchor links, if an unlabeled anchor link a=(u,v) is identified as positive (i.e., existing), all the other unlabeled anchor links incident to account u or account v will be negative (i.e., non-existing) automatically. Viewed in such a perspective, asking for the labels of potential positive anchor links in the unlabeled set will be rewarding in the active anchor link prediction problem. Various novel anchor link information gain measures are defined in this paper, based on which several constraint active anchor link prediction methods are introduced. Extensive experiments have been done on real-world social network datasets to compare the performance of these methods with state-of-art anchor link prediction methods. The experimental results show that the proposed Mean-entropy-based Constrained Active Learning (MC) method can outperform other methods with significant advantages. PMID:28771201
Zhu, Junxing; Zhang, Jiawei; Wu, Quanyuan; Jia, Yan; Zhou, Bin; Wei, Xiaokai; Yu, Philip S
2017-08-03
Nowadays, people are usually involved in multiple heterogeneous social networks simultaneously. Discovering the anchor links between the accounts owned by the same users across different social networks is crucial for many important inter-network applications, e.g., cross-network link transfer and cross-network recommendation. Many different supervised models have been proposed to predict anchor links so far, but they are effective only when the labeled anchor links are abundant. However, in real scenarios, such a requirement can hardly be met and most anchor links are unlabeled, since manually labeling the inter-network anchor links is quite costly and tedious. To overcome such a problem and utilize the numerous unlabeled anchor links in model building, in this paper, we introduce the active learning based anchor link prediction problem. Different from the traditional active learning problems, due to the one-to-one constraint on anchor links, if an unlabeled anchor link a = ( u , v ) is identified as positive (i.e., existing), all the other unlabeled anchor links incident to account u or account v will be negative (i.e., non-existing) automatically. Viewed in such a perspective, asking for the labels of potential positive anchor links in the unlabeled set will be rewarding in the active anchor link prediction problem. Various novel anchor link information gain measures are defined in this paper, based on which several constraint active anchor link prediction methods are introduced. Extensive experiments have been done on real-world social network datasets to compare the performance of these methods with state-of-art anchor link prediction methods. The experimental results show that the proposed Mean-entropy-based Constrained Active Learning (MC) method can outperform other methods with significant advantages.
ERIC Educational Resources Information Center
Schwartz, Seth J.; Montgomery, Marilyn J.; Briones, Ervin
2006-01-01
The present paper advances theoretical propositions regarding the relationship between acculturation and identity. The most central thesis argued is that acculturation represents changes in cultural identity and that personal identity has the potential to "anchor" immigrant people during their transition to a new society. The article emphasizes…
A Rapid Auto-Indexing Technology for Designing Readable E-Learning Content
ERIC Educational Resources Information Center
Yu, Pao-Ta; Liao, Yuan-Hsun; Su, Ming-Hsiang; Cheng, Po-Jen; Pai, Chun-Hsuan
2012-01-01
A rapid scene indexing method is proposed to improve retrieval performance for students accessing instructional videos. This indexing method is applied to anchor suitable indices to the instructional video so that students can obtain several small lesson units to gain learning mastery. The method also regulates online course progress. These…
ERIC Educational Resources Information Center
Thomas, Cathy Newman; Rieth, Herbert J.
2011-01-01
More than 20 years have passed since the Cognition and Technology Group at Vanderbilt University first conceptualized and began to explore how to effectively operationalize cognitive learning theory in applied instructional settings, innovatively infusing their model with emerging technologies. Yet, to date a comprehensive review of findings on…
Community identities as visions for landscape change
William P. Stewart; Derek Liebert; Kevin W. Larkin
2004-01-01
Residents' felt senses of their community can play substantial roles in determining visions for landscape change. Community identities are often anchored in tangible environments and events of a community, and have the potential to serve as visions for landscape planning processes. Photo-elicitation is applied in this study to connect community-based meanings to...
33 CFR 100.920 - Tug Across the River, Detroit, MI.
Code of Federal Regulations, 2010 CFR
2010-07-01
... desiring to enter or operate within the regulated area shall contact the Coast Guard Patrol Commander to.... (a) Regulated Area. A regulated area is established to include all waters of the Detroit River... of § 100.901 apply. No vessel may enter, transit through, or anchor within the regulated area without...
Evaluating Equating Results: Percent Relative Error for Chained Kernel Equating
ERIC Educational Resources Information Center
Jiang, Yanlin; von Davier, Alina A.; Chen, Haiwen
2012-01-01
This article presents a method for evaluating equating results. Within the kernel equating framework, the percent relative error (PRE) for chained equipercentile equating was computed under the nonequivalent groups with anchor test (NEAT) design. The method was applied to two data sets to obtain the PRE, which can be used to measure equating…
Comparison of holding strength of suture anchors for hepatic and renal parenchyma.
Ames, Caroline D; Perrone, Juan M; Frisella, Alison J; Morrissey, Kevin; Landman, Jaime
2005-12-01
Various laparoscopic devices have been described for suture anchoring during solidorgan parenchymal closure. Application of these devices expedites the closure of parenchymal defects and minimizes ischemia time. We compared different technologies as suture anchors for parenchymal closure. A tensometer was used to determine the amount of tension necessary to dislodge each of five different clips from Vicryl suture alone or against two different substrates (fresh pig kidney and liver) with and without an intervening pledget. The clips investigated were the Lapra-Ty (Ethicon), Endoclip II (US Surgical), small Horizon Ligating Clips (Weck), Hem-o-lok Medium Polymer Clips (Week), and a novel Suture-clip (Applied Medical). ANOVA and two-sided Fisher's exact test provided statistical analysis. The force required to dislodge the Lapra-Ty clip from bare suture for both 0 and 1 Vicryl (7.0 N) was approximately fourfold the force required to dislodge the Endoclips or the 5-mm or 10-mm Hem-o-lok clips (p<0.01). When clips were applied to suture running through renal or liver parenchyma, the novel Suture-clip required the greatest tension to dislodge (P<0.01), followed by the Horizon and Lapra-Ty clips. There were no statistically significant differences in the tension required to dislodge a given clip from the two parenchymal substrates or in the presence or absence of a pledget. In our experimental model, the Suture-clip, Lapra-Ty, and Horizon clips required significantly greater tension to dislodge than the Hem-o-lok and Endoclip clips. The addition of a pledget did not improve tension resistance.
NASA Technical Reports Server (NTRS)
Flachbart, R. H.; Hedayat, A.; Holt, K. A.; Sims, J.; Johnson, E. F.; Hastings, L. J.; Lak, T.
2013-01-01
Cryogenic upper stages in the Space Shuttle program were prohibited primarily due to a safety risk of a 'return to launch site' abort. An upper stage concept addressed this concern by proposing that the stage be launched empty and filled using shuttle external tank residuals after the atmospheric pressure could no longer sustain an explosion. However, only about 5 minutes was allowed for tank fill. Liquid hydrogen testing was conducted within a near-ambient environment using the multipurpose hydrogen test bed 638.5 ft3 (18m3) cylindrical tank with a spray bar mounted longitudinally inside. Although the tank was filled within 5 minutes, chilldown of the tank structure was incomplete, and excessive tank pressures occurred upon vent valve closure. Elevated tank wall temperatures below the liquid level were clearly characteristic of film boiling. The test results have substantial implications for on-orbit cryogen transfer since the formation of a vapor film would be much less inhibited due to the reduced gravity. However, the heavy tank walls could become an asset in normal gravity testing for on-orbit transfer, i.e., if film boiling in a nonflight weight tank can be inhibited in normal gravity, then analytical modeling anchored with the data could be applied to reduced gravity environments with increased confidence.
Coons, David A; Barber, F Alan; Herbert, Morley A
2006-11-01
This study evaluated the strength and suture-tendon interface security of different suture configurations from triple-suture-loaded anchors. A juvenile bovine infraspinatus tendon was detached and repaired by use of 4 different suture combinations from 2 suture anchors: 3 simple sutures in each anchor (ThreeVo anchor; Linvatec, Largo, FL); 2 peripheral simple stitches and 1 central horizontal mattress suture passed deeper into the tendon, creating a larger footprint (bigfoot-print anchor); 2 peripheral simple stitches with 1 central horizontal mattress stitch passed through the same holes as the simple sutures (stitch-of-Burns); and 2 simple stitches (TwoVo anchor; Linvatec). The constructs were cyclically loaded between 10 N and 180 N for 3,500 cycles and then destructively tested. The number of cycles required to create a 5-mm gap and a 10-mm gap and the ultimate load to failure and failure mode were recorded. The ThreeVo anchor was strongest and most resistant to cyclic loading (P < .01). The TwoVo anchor was least resistant to cyclic loading. The stitch-of-Burns anchor was more resistant to cyclic loading than both the bigfoot-print anchor and the TwoVo anchor (P < .03). The ThreeVo, stitch-of-Burns, and TwoVo anchors were stronger than the bigfoot-print anchor (P < .05). Three simple sutures in an anchor hold better than two simple sutures. Three simple sutures provide superior suture-tendon security than combinations of one mattress and two simple stitches subjected to cyclic loading. A central mattress stitch placed more medially than two peripheral simple stitches (bigfoot-print anchor) configured to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as three simple stitches (ThreeVo anchor). Placing a central mattress stitch more medially than 2 peripheral simple stitches to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as 3 simple stitches.
Guide for Inspection of Coatings Applied to Hydraulic Structures.
1986-04-01
observed, many specifiers provide that the surfaces must be sweep blasted to provide a " tooth " before topcoating, or wiped with some strong solvent. CW...termed anchor pattern, profile, or " tooth ," and is essentially a pattern of peaks and valleys on the steel surface. This pattern is obtained by abrasive...situation, a sealer must be applied. Blushing Blushing is the hazing or whitening of the finish as a result of the absorption and "" retention of
Barber, F Alan; Bava, Eric D; Spenciner, David B; Piccirillo, Justin
2013-06-01
The purpose of this study was to assess the mechanical performance of biocomposite knotless lateral row anchors based on both anchor design and the direction of pull. Two lateral row greater tuberosity insertion sites (anterior and posterior) were identified in matched pairs of fresh-frozen human cadaveric shoulders DEXA (dual energy X-ray absorptiometry) scanned to verify comparability. The humeri were stripped of all soft tissue and 3 different biocomposite knotless lateral row anchors: HEALIX Knotless BR (DePuy Mitek, Raynham MA), BioComposite PushLock (Arthrex, Naples, FL), and Bio-SwiveLock (Arthrex). Fifty-two anchors were distributed among the insertion locations and tested them with either an anatomic or axial pull. A fixed-gauge loop (15 mm) of 2 high-strength sutures from each anchor was created. After a 10-Nm preload, anchors were cycled from 10 to 45 Nm at 0.5 Hz for 200 cycles and tested to failure at 4.23 mm/second. The load to reach 3 mm and 5 mm displacement, ultimate failure load, displacement at ultimate failure, and failure mode were recorded. Threaded anchors (Bio-SwiveLock, P = .03; HEALIX Knotless, P = .014) showed less displacement with anatomic testing than did the nonthreaded anchor (BioComposite PushLock), and the HEALIX Knotless showed less overall displacement than did the other 2 anchors. The Bio-SwiveLock exhibited greater failure loads than did the other 2 anchors (P < .05). Comparison of axial and anatomic loading showed no maximum load differences for all anchors as a whole (P = .1084). Yet, anatomic pulling produced higher failure loads than did axial pulling for the Bio-SwiveLock but not for the BioComposite PushLock or the HEALIX Knotless. The nonthreaded anchor (BioComposite PushLock) displayed lower failure loads than did both threaded anchors with axial pulling. Threaded biocomposite anchors (HEALIX Knotless BR and Bio-SwiveLock) show less anatomic loading displacement and higher axial failure loads than do the nonthreaded (BioComposite PushLock) anchor. The HEALIX Knotless BR anchor showed less displacement than did the BioComposite PushLock and Bio-SwiveLock anchors. Neither axial nor anatomic loading had an effect on overall anchor displacement. Because of the strength profiles exhibited, this study supports the use of biocomposite anchors, which have definite advantages over polyetheretherketone (PEEK) and metal products. However, the nonthreaded BioComposite PushLock anchor cannot be recommended. Copyright © 2013 Arthroscopy Association of North America. All rights reserved.
Understanding the low uptake of bone-anchored hearing aids: a review.
Powell, R; Wearden, A; Pardesi, S M; Green, K
2017-03-01
Bone-anchored hearing aids improve hearing for patients for whom conventional behind-the-ear aids are problematic. However, uptake of bone-anchored hearing aids is low and it is important to understand why this is the case. A narrative review was conducted. Studies examining why people accept or decline bone-anchored hearing aids and satisfaction levels of people with bone-anchored hearing aids were reviewed. Reasons for declining bone-anchored hearing aids included limited perceived benefits, concerns about surgery, aesthetic concerns and treatment cost. No studies providing in-depth analysis of the reasons for declining or accepting bone-anchored hearing aids were identified. Studies of patient satisfaction showed that most participants reported benefits with bone-anchored hearing aids. However, most studies used cross-sectional and/or retrospective designs and only included people with bone-anchored hearing aids. Important avenues for further research are in-depth qualitative research designed to fully understand the decision-making process for bone-anchored hearing aids and rigorous quantitative research comparing satisfaction of people who receive bone-anchored hearing aids with those who receive alternative (or no) treatments.
Simmons, Joseph P; LeBoeuf, Robyn A; Nelson, Leif D
2010-12-01
Increasing accuracy motivation (e.g., by providing monetary incentives for accuracy) often fails to increase adjustment away from provided anchors, a result that has led researchers to conclude that people do not effortfully adjust away from such anchors. We challenge this conclusion. First, we show that people are typically uncertain about which way to adjust from provided anchors and that this uncertainty often causes people to believe that they have initially adjusted too far away from such anchors (Studies 1a and 1b). Then, we show that although accuracy motivation fails to increase the gap between anchors and final estimates when people are uncertain about the direction of adjustment, accuracy motivation does increase anchor-estimate gaps when people are certain about the direction of adjustment, and that this is true regardless of whether the anchors are provided or self-generated (Studies 2, 3a, 3b, and 5). These results suggest that people do effortfully adjust away from provided anchors but that uncertainty about the direction of adjustment makes that adjustment harder to detect than previously assumed. This conclusion has important theoretical implications, suggesting that currently emphasized distinctions between anchor types (self-generated vs. provided) are not fundamental and that ostensibly competing theories of anchoring (selective accessibility and anchoring-and-adjustment) are complementary. PsycINFO Database Record (c) 2010 APA, all rights reserved.
Seismic explosive charge loader and anchor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mcreynolds, O.B.
1981-07-14
An improved seismic explosive charge loader and anchor for loading and anchoring explosives in cylindrical containers in bore holes is disclosed, which includes a snap in spring band shaped anchor which effectively anchors the loader in the well bore against upward movement, one aspect of the invention includes a snap lock threaded connection for securing an explosive container having interrupted threads to the loader and anchor, and the loader and anchor is constructed and arranged to maintain a detonator in place in the explosive container thereby assuring detonation of the explosive.
Analysis of self-heating of thermally assisted spin-transfer torque magnetic random access memory
Deschenes, Austin; Muneer, Sadid; Akbulut, Mustafa; ...
2016-11-11
Thermal assistance has been shown to significantly reduce the required operation power for spin torque transfer magnetic random access memory (STT-MRAM). Proposed heating methods include modified material stack compositions that result in increased self-heating or external heat sources. Here, we analyze the self-heating process of a standard perpendicular magnetic anisotropy STT-MRAM device through numerical simulations in order to understand the relative contributions of Joule, thermoelectric Peltier and Thomson, and tunneling junction heating. A 2D rotationally symmetric numerical model is used to solve the coupled electro-thermal equations including thermoelectric effects and heat absorbed or released at the tunneling junction. We comparemore » self-heating for different common passivation materials, positive and negative electrical current polarity, and different device thermal anchoring and boundaries resistance configurations. The variations considered are found to result in significant differences in maximum temperatures reached. Average increases of 3 K, 10 K, and 100 K for different passivation materials, positive and negative polarity, and different thermal anchoring configurations, respectively, are observed. Furthermore, the highest temperatures, up to 424 K, are obtained for silicon dioxide as the passivation material, positive polarity, and low thermal anchoring with thermal boundary resistance configurations. Interestingly it is also found that due to the tunneling heat, Peltier effect, device geometry, and numerous interfacial layers around the magnetic tunnel junction (MTJ), most of the heat is dissipated on the lower potential side of the magnetic junction. We have observed this asymmetry in heating and is important as thermally assisted switching requires heating of the free layer specifically and this will be significantly different for the two polarity operations, set and reset.« less
Weiner, Richard L; Yeung, Anthony; Montes Garcia, Carlos; Tyler Perryman, Laura; Speck, Benjamin
2016-10-01
Test a miniaturized neurostimulator transforaminally placed at the dorsal root ganglion (DRG) and evaluate the device's safety and efficacy in treating failed back surgery syndrome (FBSS) low back pain. Pilot, two-phase study. Eleven subjects with chronic intractable neuropathic trunk and/or lower limbs pain were included. The system consisted of an implantable, miniaturized stimulator, provided by Stimwave Technologies (Freedom-4) and an external transmitter. Only one stimulator per subject was implanted unilaterally and transforaminally at L1 to L5 levels. During Phase 1 of the study, the stimulators were not anchored. In Phase 2, the stimulators were anchored. Subjects were treated during 45 days after which the stimulator was removed. Pain reduction, implant duration, and stimulator migration were registered. Overall pain reduction was 59.9%, with only one device placed at one location, covering only a portion of the painful areas in the majority of the subjects. In Phase 1, the non-anchored stimulators migrated a mean of 8.80 mm and in Phase 2 a mean of 1.83 mm. Stimulator migration did not correlate with changes in pain relief. Mean time-to-implant duration was 10 minutes and no adverse events were reported during implant, follow-up period, or after explant. The pain reduction results indicate that the Freedom-4 spinal cord stimulation (SCS) Wireless System is a viable treatment of low back pain through stimulation of the DRG, and better overall pain reduction may be achieved by implanting multiple devices. With short percutaneous implant times and excellent safety profile, this new system may offer health cost savings. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Kirov, Ilya; Van Laere, Katrijn; De Riek, Jan; De Keyser, Ellen; Van Roy, Nadine; Khrustaleva, Ludmila
2014-01-01
In order to anchor Rosa linkage groups to physical chromosomes, a combination of the Tyramide-FISH technology and the modern molecular marker system based on High Resolution Melting (HRM) is an efficient approach. Although, Tyramide-FISH is a very promising technique for the visualization of short DNA probes, it is very challenging for plant species with small chromosomes such as Rosa. In this study, we successfully applied the Tyramide-FISH technique for Rosa and compared different detection systems. An indirect detection system exploiting biotinylated tyramides was shown to be the most suitable technique for reliable signal detection. Three gene fragments with a size of 1100 pb–1700 bp (Phenylalanine Ammonia Lyase, Pyrroline-5-Carboxylate Synthase and Orcinol O-Methyl Transferase) have been physically mapped on chromosomes 7, 4 and 1, respectively, of Rosa wichurana. The signal frequency was between 25% and 40%. HRM markers of these 3 gene fragments were used to include the gene fragments on the existing genetic linkage map of Rosa wichurana. As a result, three linkage groups could be anchored to their physical chromosomes. The information was used to check for synteny between the Rosa chromosomes and Fragaria. PMID:24755945
ERIC Educational Resources Information Center
Liu, Jinghua; Zu, Jiyun; Curley, Edward; Carey, Jill
2014-01-01
The purpose of this study is to investigate the impact of discrete anchor items versus passage-based anchor items on observed score equating using empirical data.This study compares an "SAT"® critical reading anchor that contains more discrete items proportionally, compared to the total tests to be equated, to another anchor that…
Heinen, Silke; Weinhart, Marie
2017-03-07
For a meaningful correlation of surface coatings with their respective biological response reproducible coating procedures, well-defined surface coatings, and thorough surface characterization with respect to layer thickness and grafting density are indispensable. The same applies to polymeric monolayer coatings which are intended to be used for, e.g., fundamental studies on the volume phase transition of surface end-tethered thermoresponsive polymer chains. Planar gold surfaces are frequently used as model substrates, since they allow a variety of straightforward surface characterization methods. Herein we present reproducible grafting-to procedures performed with thermoresponsive poly(glycidyl ether) copolymers composed of glycidyl methyl ether (GME) and ethyl glycidyl ether (EGE). The copolymers feature different molecular weights (2 kDa, 9 kDa, 24 kDa) and are equipped with varying sulfur-containing anchor groups in order to achieve adjustable grafting densities on gold surfaces and hence control the tethered polymers' chain conformation. We determined "wet" and "dry" thicknesses of these coatings by QCM-D and ellipsometry measurements and deduced anchor distances and degrees of chain overlap of the polymer chains assembled on gold. Grafting under cloud point conditions allowed for higher degrees of chain overlap compared to grafting from a good solvent like ethanol, independent of the used sulfur-containing anchor group for polymers with low (2 kDa) and medium (9 kDa) molecular weights. By contrast, the achieved grafting densities and thus chain overlaps of surface-tethered polymers with high (24 kDa) molecular weights were identical for both grafting methods. Monolayers prepared from an ethanolic solution of poly(glycidyl ether)s equipped with sterically demanding disulfide-containing anchors revealed the lowest degrees of chain overlap. The ratio of the radius of gyration to the anchor distance (2 R g /l) of the latter coating was found to be lower than 1.4, indicating that the assembly was rather in the mushroom-like than in the brush regime. Polymer chains with thiol-containing anchors of different alkyl chain lengths (C 11 SH vs C 4 SH) formed assemblies with comparable degrees of chain overlap with 2 R g /l values above 1.4 and are thus in the brush regime. Molecular weights influenced the achievable degree of chain overlap on the surface. Coatings prepared with the medium molecular weight polymer (9 kDa) resulted in the highest chain packing density. Control of grafting density and thus chain overlap in different regimes (brush vs mushroom) on planar gold substrates are attainable for monolayer coatings with poly(GME-ran-EGE) by adjusting the polymer's molecular weight and anchor group as well as the conditions for the grafting-to procedure.
78 FR 45104 - Model Manufactured Home Installation Standards: Ground Anchor Installations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-26
... test methods for establishing working load design values of ground anchor assemblies used for new... anchor installations and establish standardized test methods to determine ground anchor performance and... currently no national test method for rating and certifying ground anchor assemblies in different soil...
A classification of growth friendly spine implants.
Skaggs, David L; Akbarnia, Behrooz A; Flynn, John M; Myung, Karen S; Sponseller, Paul D; Vitale, Michael G
2014-01-01
Various types of spinal implants have been used with the objective of minimizing spinal deformities while maximizing the spine and thoracic growth in a growing child with a spinal deformity. The aim of this study was to describe a classification system of growth friendly spinal implants to allow researchers and clinicians to have a common language and facilitate comparative studies. Growth friendly spinal implant systems fall into 3 categories based upon the forces of correction the implants exert on the spine, which are as follows: Distraction-based systems correct spinal deformities by mechanically applying a distractive force across a deformed segment with anchors at the top and bottom of the implants, which commonly attach to the spine, rib, and/or the pelvis. The present examples of distraction-based implants are spine-based or rib-based growing rods, vertical expandable titanium rib prosthesis, and remotely expandable devices. Compression-based systems correct spinal deformities with a compressive force applied to the convexity of the curve causing convex growth inhibition. This compressive force may be generated both mechanically at the time of implantation, as well as over time resulting from longitudinal growth of vertebral endplates hindered by the spinal implants. Examples of compression-based systems are vertebral staples and tethers. Guided growth systems correct spinal deformity by anchoring multiple vertebrae (usually including the apical vertebrae) to rods with mechanical forces including translation at the time of the initial implant. The majority of the anchors are not rigidly attached to the rods, thus permitting longitudinal growth over time as the anchors slide over the rods. Examples of guided growth systems include the Luque trolley and Shilla. Each system has its benefits and shortcomings. Knowledge of the fundamental principles upon which these systems are based may aid the clinician to choose an appropriate treatment for patients. Having a common language for these systems may aid in comparative research. Vertical expandable titanium rib prosthesis is used with humanitarian exemption. The other devices mentioned in this manuscript are not approved for growing constructs by the Food and Drug Administration and are used off-label.
Editorial Commentary: All-Suture Anchors, Foam Blocks, and Biomechanical Testing.
Brand, Jefferson C
2017-06-01
Barber's biomechanical work is well known to Arthroscopy's readers as thorough, comprehensive, and inclusive of new designs as they become available. In "All-Suture Anchors: Biomechanical Analysis of Pullout Strength, Displacement, and Failure Mode," the latest iteration, Barber and Herbert test all-suture anchors in both porcine femurs and biphasic foam. While we await in vivo clinical trials that compare all-suture anchors to currently used anchors, Barber and Herbert have provided data to inform anchor choice, and using their biomechanical data at time zero from all-suture anchor trials in an animal model, we can determine the anchors' feasibility for human clinical investigations. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Influence of Anchoring on Burial Depth of Submarine Pipelines
Zhuang, Yuan; Li, Yang; Su, Wei
2016-01-01
Since the beginning of the twenty-first century, there has been widespread construction of submarine oil-gas transmission pipelines due to an increase in offshore oil exploration. Vessel anchoring operations are causing more damage to submarine pipelines due to shipping transportation also increasing. Therefore, it is essential that the influence of anchoring on the required burial depth of submarine pipelines is determined. In this paper, mathematical models for ordinary anchoring and emergency anchoring have been established to derive an anchor impact energy equation for each condition. The required effective burial depth for submarine pipelines has then been calculated via an energy absorption equation for the protection layer covering the submarine pipelines. Finally, the results of the model calculation have been verified by accident case analysis, and the impact of the anchoring height, anchoring water depth and the anchor weight on the required burial depth of submarine pipelines has been further analyzed. PMID:27166952
NASA Astrophysics Data System (ADS)
Zhou, Zhi; Zhang, Zhichun; Wang, Chuan; Ou, Jinping
2006-03-01
FRP ( Fiber Reinforced Polymer ) has become the popular material to alternate steel in civil engineering under harsh corrosion environment. But due to its low shear strength ability, the anchor for FRP is most important for its practical application. However, the strain state of the surface between FRP and anchor is not fully understood due to that there is no proper sensor to monitor the inner strain in the anchor by traditional method. In this paper, a new smart FBG-based FRP anchor is brought forward, and the inner strain distribution of FRP anchor has been monitored using FRP-OFBG sensors, a smart FBG-embedded FRP rebar, which is pre-embedded in the FRP rod and cast in the anchor. Based on the strain distribution information the bonding shear stress on the surface of FRP rod along the anchor can also be obtained. This method can supply important information for FRP anchor design and can also monitor the anchorage system, which is useful for the application of FRP in civil engineering. The experimental results also show that the smart FBG-based FRP anchor can give direct information of the load and damage of the FRP anchor.
Paek, Hye-Jin; Yoon, Hye Jin; Hove, Thomas
2011-03-01
Despite the increased use of health claims in food advertising, few studies have investigated how specific nutrition claims have differential effects depending on how they are presented. In this context, the current study tests the anchoring hypothesis. Anchoring refers to a common human tendency to evaluate information differently depending on the presence or absence of a numerical "anchor" or reference point. Two (pilot and main) experimental studies explore anchoring effects on audience response to food advertising both directly and moderated by cognitive, motivational, and message factors. The pilot study finds that food product ads employing nutrition claims with an anchor rather than without an anchor generate two results: First, participants perceive the product to have lower fat/lower calorie contents (anchoring hypothesis); second, they prefer the messages with an anchor over those without an anchor. The main study reports that when anchoring is successfully evoked, it produces favorable attitudes toward the ad, favorable attitudes toward the brand, and purchase intention-but only when moderated by health orientation, claim believability, and nutrition knowledge. Practical implications are provided with respect to regulatory guidelines and effective communication strategies for promoting low-fat and low-calorie products in food advertising.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-09
... External Review Draft of the Guidance for Applying Quantitative Data To Develop Data-Derived Extrapolation... Applying Quantitative Data to Develop Data-Derived Extrapolation Factors for Interspecies and Intraspecies... Applying Quantitative Data to Develop Data-Derived Extrapolation Factors for Interspecies and Intraspecies...
Comparability of Health Care Responsiveness in Europe
ERIC Educational Resources Information Center
Sirven, Nicolas; Santos-Eggimann, Brigitte; Spagnoli, Jacques
2012-01-01
The aim of this paper is to measure and to correct for the potential incomparability of responses to the SHARE survey on health care responsiveness. A parametric approach based on the use of anchoring vignettes is applied to cross-sectional data (2006-2007) in eleven European countries. More than 7,000 respondents aged 50 years old and over were…
From Positivism to Critical Theory: School-Community Relations toward Community Equity Literacy
ERIC Educational Resources Information Center
Green, Terrance L.
2017-01-01
In recent years, research on urban school-community relations has emerged with renewed vigor and a myriad of suggestions for how to best approach the topic. While most of these suggestions are anchored in positivist and interpretive epistemologies, a growing number of scholars are applying more critical approaches to school-community relations…
NASA Astrophysics Data System (ADS)
Wu, Tao
We describe two new methodologies leading to the formation of novel surface-anchored polymer assemblies on solid substrates. While the main goal is to understand the fundamentals pertaining to the preparation and properties of the surface-bound polymer assemblies (including neutral and chargeable polymers), several examples also are mentioned throughout the Thesis that point out to practical applications of such structures. The first method is based on generating assemblies comprising anchored polymers with a gradual variation of grafting densities on solid substrates. These structures are prepared by first covering the substrate with a molecular gradient of the polymerization initiator, followed by polymerization from these substrate-bound initiator centers ("grafting from"). We apply this technique to prepare grafting density gradients of poly(acryl amide) (PAAm) and poly(acrylic acid) (PAA) on silica-covered substrates. We show that using the grafting density gradient geometry, the characteristics of surface-anchored polymers in both the low grafting density ("mushroom") regime as well as the high grafting density ("brush") regime can be accessed conveniently on a single sample. We use a battery of experimental methods, including Fourier transform infrared spectroscopy (FTIR), Near-edge absorption fine structure spectroscopy (NEXAFS), contact angle, ellipsometry, to study the characteristics of the surface-bound polymer layers. We also probe the scaling laws of neutral polymer as a function of grafting density, and for weak polyelectrolyte, in addition to the grafting density, we study the affect of solution ionic strength and pH values. In the second novel method, which we coined as "mechanically assisted polymer assembly" (MAPA), we form surface anchored polymers by "grafting from" polymerization initiators deposited on elastic surfaces that have been previously extended uniaxially by a certain length increment, Deltax. Upon releasing the strain in the substrate after completion of polymerization, we show the grafting density of the polymers grafted to flexible substrates can be tuned as a function of Deltax.
Zhang, Chuan-Kai; Liu, Chen; Han, Bing; Feng, Hui; Chen, Qi-Zhong; Sunx, Sun Yi-Yan
2017-04-25
To study feasibility and reliability of reconstruction of the acromioclavicular ligament with double-row suture anchor for the treatment of acromioclavicular joint dislocation through coracoid coronal CT measurement, and to provide a new operation method for treating acromioclavicular joint dislocation. Total 60 healthy people received CT examination of shoulder joint, including 30 males and 30 females, ranging in age from 18 to 50 years old. The coronal width, thickness and 20 degree camber angle in the medial part of the toot of coronal were measured using CT scan. The results were applied to clinical treatment for 12 patients with acromioclavicular joint dislocation of Tossy III type. The width in the medial part of the root of the coracoid was(17.65±1.82) mm(left side) and (17.67±1.80) mm(right side) in males; (16.55±1.78) mm(left side) and (16.52±1.74) mm (right side) in females. The vertical thickness of the roots of the coracoid: (13.11±2.11) mm(left side) and (13.16±2.09) mm(right side) in males;(12.79±2.21) mm(left side) and (12.76±2.19) mm (right side) in females. The thickness of 20 degrees camber angle of the coracoid roots: (16.32±1.74) mm (left side) and (16.30±1.69) mm(right side) in males; (15.68±1.44) mm(left side) and (15.67±1.43) mm(right side) in females. Total 12 patients were treated with anchor nail with extraversion 20 degrees. The postoperative X-ray films showed bone anchors were located in the coracoid process, no bone splitting. Double-row suture anchor of 5 mm diameter nails can be placed into coracoid with extraversion 20 degrees, which is safety.
Van der Bracht, Hans; Van den Langenbergh, Tom; Pouillon, Marc; Verhasselt, Skrallan; Verniers, Philippe; Stoffelen, Danny
2018-05-22
This study investigated the feasibility and safety of all-suture anchors in arthroscopic rotator cuff repair. All patients were diagnosed with a rotator cuff tear by ultrasound or magnetic resonance imaging (MRI). Patients with partial tears, massive tears, subscapularis tears, or previous shoulder surgery, were excluded. MRI and clinical outcome were investigated in all patients at 1.58 years (range, 1.0-2.0 years) after rotator cuff repair with all-suture anchors (prospective case series). Integrity of the cuff repair, cyst formation (encapsulated fluid signal around the anchor), ingrowth of the bone into the anchor, and integrity of the bone tunnel border were evaluated for 47 anchors. Clinical results were evaluated using the Constant-Murley score. An MRI evaluation was performed in 20 patients at 1.58 years (range, 1.0-2.0 years) after rotator cuff repair with all-suture anchors. MRI evaluation showed a very small rim of fluid around 10% of the anchors. None of the anchors showed cyst formation with fluid diameter more than twice the anchor diameter. In approximately 90% of the anchors, no fluid could be detected between the anchors and the edge of the bony tunnel. Full rotator cuff integrity was seen in 19 patients. Only 1 patient sustained a retear. Clinical results comparable with an arthroscopic rotator cuff repair using classic anchors were seen. This prospective clinical cohort study shows promising early radiographic and clinical results after arthroscopic rotator cuff repair using all-suture anchors. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Pietschmann, Matthias F; Froehlich, Valerie; Ficklscherer, Andreas; Wegener, Bernd; Jansson, Volkmar; Müller, Peter E
2008-01-01
Various suture anchors are available for rotator cuff repair. For arthroscopic application, a knotless anchor was developed to simplify the intra-operative handling. We compared the new knotless anchor (BIOKNOTLESStrade mark RC; DePuy Mitek, Raynham, MA) with established absorbable and titanium suture anchors (UltraSorbtrade mark and Super Revo 5mmtrade mark; ConMed Linvatec, Utica, NY). Each anchor was tested on 6 human cadaveric shoulders. The anchors were inserted into the greater tuberosity. An incremental cyclic loading was performed. Ultimate failure loads, anchor displacement, and mode of failure were recorded. The anchor displacement of the BIOKNOTLESStrade mark RC (15.3 +/- 5.3 mm) after the first cycle with 75 N was significantly higher than with the two other anchors (Super Revo 2.1 +/- 1.6 mm, UltraSorb: 2.7 +/- 1.1 mm). There was no significant difference in the ultimate failure loads of the 3 anchors. Although the Bioknotlesstrade mark RC indicated comparable maximal pullout strength, it bares the risk of losing contact between the tendon-bone-interface due to a significantly higher system displacement. Therefore, gap formation between the bone and the soft tissue fixation jeopardizes the repair. Bioknotlesstrade mark RC should be used in the lateral row only when a double row technique for rotator cuff repair is performed, and is not appropriate for rotator cuff repair if used on its own.
Zhang, Qing-Song; Liu, Sen; Zhang, Qiuyang; Xue, Yun; Ge, Dongxia; O'Brien, Michael J.; Savoie, Felix H.; You, Zongbing
2012-01-01
Objectives. The objective of this study was to compare the damage to the rotator cuff tendons caused by four different anchor systems. Methods. 20 cadaveric human shoulder joints were used for transtendon insertion of four anchor systems. The Healix Peek, Fastin RC, Bio-Corkscrew Suture, and Healix Transtend anchors were inserted through the tendons using standard transtendon procedures. The areas of tendon damage were measured. Results. The areas of tendon damage (mean ± standard deviation, n = 7) were 29.1 ± 4.3 mm2 for the Healix Peek anchor, 20.4 ± 2.3 mm2 for the Fastin RC anchor, 23.4 ± 1.2 mm2 for the Bio-Corkscrew Suture anchor, 13.7 ± 3.2 mm2 for the Healix Transtend anchor inserted directly, and 9.1 ± 2.1 mm2 for the Healix Transtend anchor inserted through the Percannula system (P < 0.001 or P < 0.001, compared to other anchors). Conclusions. In a cadaver transtendon rotator cuff repair model, smaller anchors caused less damage to the tendon tissues. The Healix Transtend implant system caused the least damage to the tendon tissues. Our findings suggest that smaller anchors should be considered when performing transtendon procedures to repair partial rotator cuff tears. PMID:22811923
The Use of Comics-Based Cases in Anchored Instruction
ERIC Educational Resources Information Center
Kneller, Matthew F.
2009-01-01
The primary purpose of this research was to understand how comics fulfill the role of anchor in an anchored instruction learning environment. Anchored instruction addresses the inert knowledge problem through the use of realistic multimedia stories, or "anchors," that embed a problem and the necessary data to solve it within the narrative. In the…
Anchoring the Deficit of the Anchor Deficit: Dyslexia or Attention?
ERIC Educational Resources Information Center
Willburger, Edith; Landerl, Karin
2010-01-01
In the anchoring deficit hypothesis of dyslexia ("Trends Cogn. Sci.", 2007; 11: 458-465), it is proposed that perceptual problems arise from the lack of forming a perceptual anchor for repeatedly presented stimuli. A study designed to explicitly test the specificity of the anchoring deficit for dyslexia is presented. Four groups, representing all…
Reinforcing mechanism of anchors in slopes: a numerical comparison of results of LEM and FEM
NASA Astrophysics Data System (ADS)
Cai, Fei; Ugai, Keizo
2003-06-01
This paper reports the limitation of the conventional Bishop's simplified method to calculate the safety factor of slopes stabilized with anchors, and proposes a new approach to considering the reinforcing effect of anchors on the safety factor. The reinforcing effect of anchors can be explained using an additional shearing resistance on the slip surface. A three-dimensional shear strength reduction finite element method (SSRFEM), where soil-anchor interactions were simulated by three-dimensional zero-thickness elasto-plastic interface elements, was used to calculate the safety factor of slopes stabilized with anchors to verify the reinforcing mechanism of anchors. The results of SSRFEM were compared with those of the conventional and proposed approaches for Bishop's simplified method for various orientations, positions, and spacings of anchors, and shear strengths of soil-grouted body interfaces. For the safety factor, the proposed approach compared better with SSRFEM than the conventional approach. The additional shearing resistance can explain the influence of the orientation, position, and spacing of anchors, and the shear strength of soil-grouted body interfaces on the safety factor of slopes stabilized with anchors.
Efird, Chad; Traub, Shaun; Baldini, Todd; Rioux-Forker, Dana; Spalazzi, Jeffrey P; Davisson, Twana; Hawkins, Monica; McCarty, Eric
2013-08-01
The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity. Single-row repairs were performed with either type I (Opus Magnum PI; ArthroCare, Austin, Texas) or type II (ReelX STT; Stryker, Mahwah, New Jersey) knotless suture anchors. The repaired tendon was cycled from 10 to 90 N for 500 cycles, followed by load to failure. Gap formation was measured at 5, 100, 200, 300, 400, and 500 cycles with a video digitizing system. Anchor type or location (anterior or posterior) had no effect on gap formation during cyclic loading regardless of position (anterior, P=.385; posterior, P=.389). Maximum load to failure was significantly greater (P=.018) for repairs performed with type II anchors (288±62 N) compared with type I anchors (179±39 N). Primary failure modes were anchor pullout and tendon tearing for type II anchors and suture slippage through the anchor for type I anchors. The internal ratcheting suture-retention mechanism of type II anchors may have helped this anchor outperform the suture-cinching mechanism of type I anchors by supporting significantly higher loads before failure and minimizing suture slippage, potentially leading to stronger repairs clinically. Copyright 2013, SLACK Incorporated.
Installation and use of epoxy-grouted rock anchors for skyline logging in southeast Alaska.
W.L. Schroeder; D.N. Swanston
1992-01-01
Field tests of the load-carrying capacity of epoxy-grouted rock anchors in poor quality bedrock on Wrangel Island in southeast Alaska demonstrated the effectiveness of rock anchors as substitutes for stump anchors for logging system guylines. Ultimate capacity depends mainly on rock hardness or strength and length of the imbedded anchor.
An earth anchor system: installation and design guide.
R.L. Copstead; D.D. Studier
1990-01-01
A system for anchoring the guylines and skylines of cable yarding equipment is presented. A description of three types of tipping plate anchors is given. Descriptions of the installation equipment and methods specific to each type are given. Procedures for determining the correct number of anchors to install are included, as are guidelines for installing the anchors so...
46 CFR 28.235 - Anchors and radar reflectors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Anchors and radar reflectors. 28.235 Section 28.235....235 Anchors and radar reflectors. (a) Each vessel must be fitted with an anchor(s) and chain(s), cable... rigged with gear that provides a radar signature from a distance of 6 miles, each nonmetallic hull vessel...
46 CFR 28.235 - Anchors and radar reflectors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Anchors and radar reflectors. 28.235 Section 28.235....235 Anchors and radar reflectors. (a) Each vessel must be fitted with an anchor(s) and chain(s), cable... rigged with gear that provides a radar signature from a distance of 6 miles, each nonmetallic hull vessel...
46 CFR 28.235 - Anchors and radar reflectors.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Anchors and radar reflectors. 28.235 Section 28.235....235 Anchors and radar reflectors. (a) Each vessel must be fitted with an anchor(s) and chain(s), cable... rigged with gear that provides a radar signature from a distance of 6 miles, each nonmetallic hull vessel...
46 CFR 28.235 - Anchors and radar reflectors.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Anchors and radar reflectors. 28.235 Section 28.235....235 Anchors and radar reflectors. (a) Each vessel must be fitted with an anchor(s) and chain(s), cable... rigged with gear that provides a radar signature from a distance of 6 miles, each nonmetallic hull vessel...
46 CFR 28.235 - Anchors and radar reflectors.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Anchors and radar reflectors. 28.235 Section 28.235....235 Anchors and radar reflectors. (a) Each vessel must be fitted with an anchor(s) and chain(s), cable... rigged with gear that provides a radar signature from a distance of 6 miles, each nonmetallic hull vessel...
Knudson, W E; Cerniglia, M W; Carro, A
1998-06-01
Many procedures performed by podiatric surgeons today require the use of a soft-tissue anchoring device. In recent years, many new anchoring devices have become available for use in the foot and ankle. The authors introduce a new soft-tissue anchoring device that has yet to be described in the podiatric literature and present two cases in which the new anchor was used.
Research-IQ: Development and Evaluation of an Ontology-anchored Integrative Query Tool
Borlawsky, Tara B.; Lele, Omkar; Payne, Philip R. O.
2011-01-01
Investigators in the translational research and systems medicine domains require highly usable, efficient and integrative tools and methods that allow for the navigation of and reasoning over emerging large-scale data sets. Such resources must cover a spectrum of granularity from bio-molecules to population phenotypes. Given such information needs, we report upon the initial design and evaluation of an ontology-anchored integrative query tool, Research-IQ, which employs a combination of conceptual knowledge engineering and information retrieval techniques to enable the intuitive and rapid construction of queries, in terms of semi-structured textual propositions, that can subsequently be applied to integrative data sets. Our initial results, based upon both quantitative and qualitative evaluations of the efficacy and usability of Research-IQ, demonstrate its potential to increase clinical and translational research throughput. PMID:21821150
Toward the Structure of Dynamic Membrane-Anchored Actin Networks
Weber, Igor
2007-01-01
In the cortex of a motile cell, membrane-anchored actin filaments assemble into structures of varying shape and function. Filopodia are distinguished by a core of bundled actin filaments within finger-like extensions of the membrane. In a recent paper by Medalia et al1 cryo-electron tomography has been used to reconstruct, from filopodia of Dictyostelium cells, the 3-dimensional organization of actin filaments in connection with the plasma membrane. A special arrangement of short filaments converging toward the filopod's tip has been called a “terminal cone”. In this region force is applied for protrusion of the membrane. Here we discuss actin organization in the filopodia of Dictyostelium in the light of current views on forces that are generated by polymerizing actin filaments, and on the resistance of membranes against deformation that counteracts these forces. PMID:19262130
Pectoralis Major Repair With Unicortical Button Fixation And Suture Tape.
Sanchez, Anthony; Ferrari, Marcio B; Frangiamore, Salvatore J; Sanchez, George; Kruckeberg, Bradley M; Provencher, Matthew T
2017-06-01
Although injuries of the pectoralis major muscle are generally uncommon, ruptures of the pectoralis major are occasionally seen in younger, more active patients who participate in weightlifting activities. These injuries usually occur during maximal contraction of the muscle, while in extension and external rotation. In the case of a rupture, operative treatment is advocated especially in young, active patients regardless of the chronicity of the injury. Various surgical techniques for reattachment of the avulsed tendon have been described, but bone tunnel and suture anchor repair techniques are most widely used. In this Technical Note, we present our preferred technique for acute pectoralis major rupture repair involving use of cortical buttons for tendon stump-to-bone fixation.
Sato, Shunsuke; Arai, Takeo; Morikawa, Takeshi; Uemura, Keiko; Suzuki, Tomiko M; Tanaka, Hiromitsu; Kajino, Tsutomu
2011-10-05
Photoelectrochemical reduction of CO(2) to HCOO(-) (formate) over p-type InP/Ru complex polymer hybrid photocatalyst was highly enhanced by introducing an anchoring complex into the polymer. By functionally combining the hybrid photocatalyst with TiO(2) for water oxidation, selective photoreduction of CO(2) to HCOO(-) was achieved in aqueous media, in which H(2)O was used as both an electron donor and a proton source. The so-called Z-scheme (or two-step photoexcitation) system operated with no external electrical bias. The selectivity for HCOO(-) production was >70%, and the conversion efficiency of solar energy to chemical energy was 0.03-0.04%.
Method and apparatus for production of subsea hydrocarbon formations
Blandford, J.W.
1995-01-17
A system for controlling, separating, processing and exporting well fluids produced from subsea hydrocarbon formations is disclosed. The subsea well tender system includes a surface buoy supporting one or more decks above the water surface for accommodating equipment to process oil, gas and water recovered from the subsea hydrocarbon formation. The surface buoy includes a surface-piercing central flotation column connected to one or more external flotation tanks located below the water surface. The surface buoy is secured to the sea bed by one or more tendons which are anchored to a foundation with piles imbedded in the sea bed. The system accommodates multiple versions on the surface buoy configuration. 20 figures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Nana; Cheng, Lu; Wang, Jianpu, E-mail: iamjpwang@njtech.edu.cn
Amino acid self-assembled monolayers are used in the fabrication of light-emitting diodes based on organic-inorganic halide perovskites. The monolayers of amino acids provide modified interfaces by anchoring to the surfaces of ZnO charge-transporting layers using carboxyl groups, leaving the amino groups to facilitate the nucleation of MAPbBr{sub 3} perovskite films. This surface-modification strategy, together with chlorobenzene-assisted fast crystallization method, results in good surface coverage and reduced defect density of the perovskite films. These efforts lead to green perovskite light emitting diodes with a low turn-on voltage of 2 V and an external quantum efficiency of 0.43% at a brightness of ∼5000 cdmore » m{sup −2}.« less
Virus-like particles as universal influenza vaccines
Kang, Sang-Moo; Kim, Min-Chul; Compans, Richard W
2012-01-01
Current influenza vaccines are primarily targeted to induce immunity to the influenza virus strain-specific hemagglutinin antigen and are not effective in controlling outbreaks of new pandemic viruses. An approach for developing universal vaccines is to present highly conserved antigenic epitopes in an immunogenic conformation such as virus-like particles (VLPs) together with an adjuvant to enhance the vaccine immunogenicity. In this review, the authors focus on conserved antigenic targets and molecular adjuvants that were presented in VLPs. Conserved antigenic targets that include the hemagglutinin stalk domain, the external domain of influenza M2 and neuraminidase are discussed in addition to molecular adjuvants that are engineered to be incorporated into VLPs in a membrane-anchored form. PMID:23002980
Pullout strength of standard vs. cement-augmented rotator cuff repair anchors in cadaveric bone.
Aziz, Keith T; Shi, Brendan Y; Okafor, Louis C; Smalley, Jeremy; Belkoff, Stephen M; Srikumaran, Uma
2018-05-01
We evaluate a novel method of rotator cuff repair that uses arthroscopic equipment to inject bone cement into placed suture anchors. A cadaver model was used to assess the pullout strength of this technique versus anchors without augmentation. Six fresh-frozen matched pairs of upper extremities were screened to exclude those with prior operative procedures, fractures, or neoplasms. One side from each pair was randomized to undergo standard anchor fixation with the contralateral side to undergo anchor fixation augmented with bone cement. After anchor fixation, specimens were mounted on a servohydraulic testing system and suture anchors were pulled at 90° to the insertion to simulate the anatomic pull of the rotator cuff. Sutures were pulled at 1 mm/s until failure. The mean pullout strength was 540 N (95% confidence interval, 389 to 690 N) for augmented anchors and 202 N (95% confidence interval, 100 to 305 N) for standard anchors. The difference in pullout strength was statistically significant (P < 0.05). This study shows superior pullout strength of a novel augmented rotator cuff anchor technique. The described technique, which is achieved by extruding polymethylmethacrylate cement through a cannulated in situ suture anchor with fenestrations, significantly increased the ultimate failure load in cadaveric human humeri. This novel augmented fixation technique was simple and can be implemented with existing instrumentation. In osteoporotic bone, it may substantially reduce the rate of anchor failure. Copyright © 2018 Elsevier Ltd. All rights reserved.
Cho, Byung-Ki; Kim, Yong-Min; Kim, Dong-Soo; Choi, Eui-Sung; Shon, Hyun-Chul; Park, Kyoung-Jin
2013-01-01
The present prospective, randomized study was conducted to compare the clinical outcomes of the modified Brostrom procedure using single and double suture anchors for chronic lateral ankle instability. A total of 50 patients were followed up for more than 2 years after undergoing the modified Brostrom procedure. Of the 50 procedures, 25 each were performed using single and double suture anchors by 1 surgeon. The Karlsson scale had improved significantly to 89.8 points and 90.6 points in the single and double anchor groups, respectively. Using the Sefton grading system, 23 cases (92%) in the single anchor group and 22 (88%) in the double anchor group achieved satisfactory results. The talar tilt angle and anterior talar translation on stress radiographs using the Telos device had improved significantly to an average of 5.7° and 4.6 mm in the single anchor group and 4.5° and 4.3 mm in the double anchor group, respectively. The double anchor technique was superior with respect to the postoperative talar tilt. The single and double suture anchor techniques produced similar clinical and functional outcomes, with the exception of talar tilt as a reference of mechanical stability. The modified Brostrom procedure using both single and double suture anchors appears to be an effective treatment method for chronic lateral ankle instability. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
The Effect of Mini and Midi Anchor Tests on Test Equating
ERIC Educational Resources Information Center
Arikan, Çigdem Akin
2018-01-01
The main purpose of this study is to compare the test forms to the midi anchor test and the mini anchor test performance based on item response theory. The research was conducted with using simulated data which were generated based on Rasch model. In order to equate two test forms the anchor item nonequivalent groups (internal anchor test) was…
The Dynamics of Scaling: A Memory-Based Anchor Model of Category Rating and Absolute Identification
ERIC Educational Resources Information Center
Petrov, Alexander A.; Anderson, John R.
2005-01-01
A memory-based scaling model--ANCHOR--is proposed and tested. The perceived magnitude of the target stimulus is compared with a set of anchors in memory. Anchor selection is probabilistic and sensitive to similarity, base-level strength, and recency. The winning anchor provides a reference point near the target and thereby converts the global…
NASA Technical Reports Server (NTRS)
1989-01-01
"Peen Plating," a NASA developed process for applying molybdenum disulfide, is the key element of Techniblast Co.'s SURFGUARD process for applying high strength solid lubricants. The process requires two machines -- one for cleaning and one for coating. The cleaning step allows the coating to be bonded directly to the substrate to provide a better "anchor." The coating machine applies a half a micron thick coating. Then, a blast gun, using various pressures to vary peening intensities for different applications, fires high velocity "media" -- peening hammers -- ranging from plastic pellets to steel shot. Techniblast was assisted by Rural Enterprises, Inc. Coating service can be performed at either Techniblast's or a customer's facility.
Park, Jong Kyu; Moon, Jong Ho; Choi, Hyun Jong; Min, Seul Ki; Lee, Tae Hoon; Cheon, Gab Jin; Cheon, Young Koog; Cho, Young Deok; Park, Sang-Heum; Kim, Sun-Joo
2011-10-01
Fully covered self-expandable metal stents (FCSEMSs) can be effectively placed in patients with benign biliary stricture (BBS). However, stent migration is an inherent problem of FCSEMSs. We evaluated the efficacy of anchoring with a 5F double-pigtail plastic stent (anchoring stent) to prevent migration of an FCSEMS in patients with BBS. Between January 2007 and December 2009, 33 of 37 consecutive patients with BBS who had experienced treatment failure of at least one plastic stent placement were prospectively enrolled in this study. The patients with BBS were randomly assigned to undergo FCSEMS placement with or without an anchoring stent (anchoring group: 16 patients; non-anchoring group: 17 patients). The main outcome measures were the stent migration rate and success rates. The technical success rate was 100% in both groups. Significantly less stent migration occurred in the anchoring group (6.3%, 1/16) than in the non-anchoring group (41.2%, 7/17; P=0.024). The median indwelling time was significantly longer in the anchoring group (154 days; range, 86-176 days) than in the non-anchoring group (114 days; range, 19-162 days; P=0.010). Improvement or resolution of the BBS was confirmed in 15 of 16 patients (93.8%) in the anchoring group, and in 12 of 17 patients (70.6%) in the non-anchoring group (P=0.101). The placement of an anchoring stent appears to be a simple and effective method of preventing premature migration of FCSEMSs in patients with BBS. Appropriately powered studies are needed to confirm this finding.
A lunar/Martian anchor emplacement system
NASA Astrophysics Data System (ADS)
Clinton, Dustin; Holt, Andrew; Jantz, Erik; Kaufman, Teresa; Martin, James; Weber, Reed
On the Moon or Mars, it is necessary to have an anchor, or a stable, fixed point able to support the forces necessary to rescue a stuck vehicle, act as a stake for a tent in a Martian gale, act as a fulcrum in the erection of general construction poles, or support tent-like regolith shields. The anchor emplacement system must be highly autonomous. It must supply the energy and stability for anchor deployment. The goal of the anchor emplacement system project is to design and build a prototype anchor and to design a conceptual anchor emplacement system. Various anchors were tested in a 1.3 cubic meter test bed containing decomposed granite. A simulated lunar soil was created by adjusting the moisture and compaction characteristics of the soil. We conducted tests on emplacement torque, amount of force the anchor could withstand before failure, anchor pull out force at various angles, and soil disturbances caused by placing the anchor. A single helix auger anchor performed best in this test bed based on energy to emplace, and the ultimate holding capacity. The anchor was optimized for ultimate holding capacity, minimum emplacement torque, and minimum soil disturbance in sandy soils yielding the following dimensions: helix diameter (4.45 cm), pitch (1.27 cm), blade thickness (0.15 cm), total length (35.56 cm), shaft diameter (0.78 cm), and a weight of 212.62 g. The experimental results showed that smaller diameter, single-helix augers held more force than larger diameter augers for a given depth. The emplacement system consists of a flywheel and a motor for power, sealed in a protective box supported by four legs. The flywheel system was chosen over a gear system based on its increased reliability in the lunar environment.
Self-tapping ability of carbon fibre reinforced polyetheretherketone suture anchors.
Feerick, Emer M; Wilson, Joanne; Jarman-Smith, Marcus; Ó'Brádaigh, Conchur M; McGarry, J Patrick
2014-10-01
An experimental and computational investigation of the self-tapping ability of carbon fibre reinforced polyetheretherketone (CFR-PEEK) has been conducted. Six CFR-PEEK suture anchor designs were investigated using PEEK-OPTIMA® Reinforced, a medical grade of CFR-PEEK. Experimental tests were conducted to investigate the maximum axial force and torque required for self-taping insertion of each anchor design. Additional experimental tests were conducted for some anchor designs using pilot holes. Computational simulations were conducted to determine the maximum stress in each anchor design at various stages of insertion. Simulations also were performed to investigate the effect of wall thickness in the anchor head. The maximum axial force required to insert a self-tapping CFR-PEEK suture anchor did not exceed 150 N for any anchor design. The maximum torque required to insert a self-tapping CFR-PEEK suture anchor did not exceed 0.8 Nm. Computational simulations reveal significant stress concentrations in the region of the anchor tip, demonstrating that a re-design of the tip geometry should be performed to avoid fracture during self-tapping, as observed in the experimental component of this study. This study demonstrates the ability of PEEK-OPTIMA Reinforced suture anchors to self-tap polyurethane foam bone analogue. This provides motivation to further investigate the self-tapping ability of CFR-PEEK suture anchors in animal/cadaveric bone. An optimised design for CFR-PEEK suture anchors offers the advantages of radiolucency, and mechanical properties similar to bone with the ability to self-tap. This may have positive implications for reducing surgery times and the associated costs with the procedure. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Scranton, Pierce E; Lawhon, S Michael; McDermott, John E
2005-07-01
Suture anchors have been developed for the fixation of ligaments, capsules, or tendons to bone. These devices have led to improved fixation, smaller incisions, earlier limb mobility, and improved outcomes. They were originally developed for use in shoulder reconstructions but are now used in almost all extremities. In the lower leg they are used in the tibia, the talus, the calcaneus, tarsal bones, and phalanges. Nevertheless, techniques for insertion and mechanisms of failure are not well described. Five suture anchors were studied to determine the pullout strength in four distal cadaver femurs and four proximal cadaver tibias from 55- and 62-year-old males. Eight hundred ninety Newton line was used, testing the anchors to failure with an Instron testing device (Instron, Norwood, MA). The anchor devices were inserted randomly and tested blindly (12 tests per anchor device, 60 tests in all). Two anchors in each group tested failed at low loads. Both types of plastic anchors had failures at the eyelet. Average pullout strength varied from 85.4 to 185.6 N. Insertion techniques are specific for each device, and they must be followed for optimal fixation. In this study, in all five groups of anchors tested two of the 12 anchors in each group failed with minimal force. On the basis of this finding we recommend that, if suture anchor fixation is necessary, at least two anchors should be used. Since there appears to be a percentage of failure in all devices, the second anchor can serve as a backup. It is imperative that surgeons be familiar with the insertion techniques of each device before use.
A lunar/Martian anchor emplacement system
NASA Technical Reports Server (NTRS)
Clinton, Dustin; Holt, Andrew; Jantz, Erik; Kaufman, Teresa; Martin, James; Weber, Reed
1993-01-01
On the Moon or Mars, it is necessary to have an anchor, or a stable, fixed point able to support the forces necessary to rescue a stuck vehicle, act as a stake for a tent in a Martian gale, act as a fulcrum in the erection of general construction poles, or support tent-like regolith shields. The anchor emplacement system must be highly autonomous. It must supply the energy and stability for anchor deployment. The goal of the anchor emplacement system project is to design and build a prototype anchor and to design a conceptual anchor emplacement system. Various anchors were tested in a 1.3 cubic meter test bed containing decomposed granite. A simulated lunar soil was created by adjusting the moisture and compaction characteristics of the soil. We conducted tests on emplacement torque, amount of force the anchor could withstand before failure, anchor pull out force at various angles, and soil disturbances caused by placing the anchor. A single helix auger anchor performed best in this test bed based on energy to emplace, and the ultimate holding capacity. The anchor was optimized for ultimate holding capacity, minimum emplacement torque, and minimum soil disturbance in sandy soils yielding the following dimensions: helix diameter (4.45 cm), pitch (1.27 cm), blade thickness (0.15 cm), total length (35.56 cm), shaft diameter (0.78 cm), and a weight of 212.62 g. The experimental results showed that smaller diameter, single-helix augers held more force than larger diameter augers for a given depth. The emplacement system consists of a flywheel and a motor for power, sealed in a protective box supported by four legs. The flywheel system was chosen over a gear system based on its increased reliability in the lunar environment.
Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures.
Barber, F Alan; Coons, David A; Ruiz-Suarez, Michell
2007-04-01
The purpose of this study was to test 4 different biodegradable suture anchors threaded with 2 high-strength sutures under cyclic loading conditions in humeral cadaveric specimens divided into 2 different age groups. Thirty-two paired human cadaveric humeri were stripped of all soft tissue. Two groups were studied: group 1, in which the mean age was 54 years, and group 2, in which the mean age was 70 years. We placed 1 suture anchor at 3 humeral sites per bone (anterior, middle, and posterior greater tuberosity). We tested 24 specimens using each of 4 anchors: TwinFix AB (Smith & Nephew Endoscopy, Andover, MA), BioZip (Stryker Endoscopy, San Jose, CA), Bio-Corkscrew FT (Arthrex, Naples, FL), and SpiraLok (DePuy Mitek, Raynham, MA). The anchor's sutures were grasped with an Instron clamp (Instron, Canton, MA), preloaded, and cycled from 10 to 60 N 500 times, followed by destructive testing. The mean displacement at 500 cycles, yield loads, failure modes, and ultimate loads were recorded. Most cyclic motion occurred during the first 100 cycles. More motion occurred in older bones than in younger bones (P < .05). The mean yield loads were greater for the young group for the SpiraLok anchors than for Bio-Corkscrew FT anchors in the young and old groups (P < .001), TwinFix anchors in the old group (P < .05), and BioZip anchors in the old group (P < .05). The ultimate failure loads for SpiraLok anchors in the young group were greater than for Bio-Corkscrew FT anchors in the young and old groups and BioZip anchors in the old group (P < .05). In group 1 TwinFix AB (P = .01) and BioZip (P = .02) ultimate loads were statistically greater than that for Bio-Corkscrew FT. The TwinFix AB failed by anchor pullout. The Bio-Corkscrew FT failed by eyelet pullout. The BioZip and SpiraLok pulled out in older bone and experienced eyelet breakage in younger bone. None of the 4 anchors reached 5 mm of displacement even after 500 loading cycles. Most of the displacement occurred in the first 100 cycles. Of all anchors tested, the Bio-Corkscrew FT recorded the lowest displacement after 500 cycles (P < .05). The SpiraLok had the highest ultimate load of all anchors tested (P < .01). Rotator cuff anchors perform differently in younger humeral bone than in older humeral bone. Most displacement with cyclic loading occurring between the anchor and bone takes place in the first 100 cycles. Anchors in older bones can be expected to fail at lower loads.
Lenart, Brett A.; Ticker, Jonathan B.
2017-01-01
Tears of the subscapularis tendon have been under-recognised until recently. Therefore, a high index of suspicion is essential for diagnosis. A directed physical examination, including the lift-off, belly-press and increased passive external rotation can help identify tears of the subscapularis. All planes on MR imaging should be carefully evaluated to identify tears of the subscapularis, retraction, atrophy and biceps pathology. Due to the tendency of the tendon to retract medially, acute and traumatic full-thickness tears should be repaired. Chronic tears without significant degeneration should be considered for repair if no contraindication exists. Arthroscopic repair can be performed using a 30-degree arthroscope and a laterally-based single row repair; one anchor for full thickness tears ⩽ 50% of tendon length and two anchors for those ⩾ 50% of tendon length. Biceps pathology, which is invariably present, should be addressed by tenotomy or tenodesis. Timing of post-operative rehabilitation is dictated by the size of the repair and the security of the repair construct. The stages of rehabilitation typically involve a period of immobilisation followed by range of movement exercises, with a delay in active internal rotation (IR) and strengthening in IR. Cite this article: EFORT Open Rev 2017;2:484–495. DOI: 10.1302/2058-5241.2.170015 PMID:29387471
Marenduzzo, D; Orlandini, E; Cates, M E; Yeomans, J M
2007-09-01
We report hybrid lattice Boltzmann (HLB) simulations of the hydrodynamics of an active nematic liquid crystal sandwiched between confining walls with various anchoring conditions. We confirm the existence of a transition between a passive phase and an active phase, in which there is spontaneous flow in the steady state. This transition is attained for sufficiently "extensile" rods, in the case of flow-aligning liquid crystals, and for sufficiently "contractile" ones for flow-tumbling materials. In a quasi-one-dimensional geometry, deep in the active phase of flow-aligning materials, our simulations give evidence of hysteresis and history-dependent steady states, as well as of spontaneous banded flow. Flow-tumbling materials, in contrast, rearrange themselves so that only the two boundary layers flow in steady state. Two-dimensional simulations, with periodic boundary conditions, show additional instabilities, with the spontaneous flow appearing as patterns made up of "convection rolls." These results demonstrate a remarkable richness (including dependence on anchoring conditions) in the steady-state phase behavior of active materials, even in the absence of external forcing; they have no counterpart for passive nematics. Our HLB methodology, which combines lattice Boltzmann for momentum transport with a finite difference scheme for the order parameter dynamics, offers a robust and efficient method for probing the complex hydrodynamic behavior of active nematics.
Comparative Study on Different Slot Forms of Prestressed Anchor Blocks
NASA Astrophysics Data System (ADS)
Fan, Rong; Si, Jianhui; Jian, Zheng
2018-03-01
In this paper, two models of prestressed pier, rectangular cavity anchor block and arch hollow anchor block are established. The ABAQUS software was used to calculate the stress of the surface of the neck of the pier and the cavity of the anchor block, through comparative analysis. The results show that compared with the rectangular cavity anchor block, the stress of the pier and the cavity can be effectively reduced when the arch hole is used, and the amount of prestressed anchor can be reduced, so as to obtain obvious economic benefits.
Dwyer, Tim; Willett, Thomas L; Dold, Andrew P; Petrera, Massimo; Wasserstein, David; Whelan, Danny B; Theodoropoulos, John S
2016-02-01
The purpose of this study was to evaluate the biomechanical behavior of an all-suture glenoid anchor in comparison with a more conventional screw-in glenoid anchor, with regard to maximum load to failure and tensile displacement. All mechanical testing was performed using an Instron ElectroPuls E1000 mechanical machine, with a 10 N pre-load and displacement rate of 10 mm/min. Force-displacement curves were generated, with calculation of maximum load, maximum displacement, displacement at 50 N and stiffness. Pretesting of handset Y-Knots in bone analog models revealed low force displacement below 60 N of force. Subsequently, three groups of anchors were tested for pull out strength in bovine bone and cadaver glenoid bone: a bioabsorbable screw-in anchor (Bio Mini-Revo, ConMed Linvatec), a handset all-suture anchor (Y-Knot, ConMed Linvatec) and a 60 N pre-tensioned all-suture anchor (Y-Knot). A total of 8 anchors from each group was tested in proximal tibia of bovine bone and human glenoids (age range 50-90). In bovine bone, the Bio Mini-Revo displayed greater maximum load to failure (206 ± 77 N) than both the handset (140 ± 51 N; P = 0.01) and the pre-tensioned Y-Knot (135 ± 46 N; P = 0.001); no significant difference was seen between the three anchor groups in glenoid bone. Compared to the screw-in anchors, the handset all-suture anchor displayed inferior fixation, early displacement and greater laxity in the bovine bone and cadaveric bone (P < 0.05). Pre-tensioning the all-suture anchor to 60 N eliminated this behavior in all bone models. Handset Y-Knots display low force anchor displacement, which is likely due to slippage in the pilot hole. Pre-tensioning the Y-Knot to 60 N eliminates this behavior. I.
Madhavan, Poornima; Wiegmann, Douglas A
2005-01-01
Automation users often disagree with diagnostic aids that are imperfectly reliable. The extent to which users' agreements with an aid are anchored to their personal, self-generated diagnoses was explored. Participants (N = 75) performed 200 trials in which they diagnosed pump failures using an imperfectly reliable automated aid. One group (nonforced anchor, n = 50) provided diagnoses only after consulting the aid. Another group (forced anchor, n = 25) provided diagnoses both before and after receiving feedback from the aid. Within the nonforced anchor group, participants' self-reported tendency to prediagnose system failures significantly predicted their tendency to disagree with the aid, revealing a cognitive anchoring effect. Agreement rates of participants in the forced anchor group indicated that public commitment to a diagnosis did not strengthen this effect. Potential applications include the development of methods for reducing cognitive anchoring effects and improving automation utilization in high-risk domains.
Thrust bolting: roof bolt support apparatus
Tadolini, Stephen C.; Dolinar, Dennis R.
1992-01-01
A method of installing a tensioned roof bolt in a borehole of a rock formation without the aid of a mechanical anchoring device or threaded tensioning threads by applying thrust to the bolt (19) as the bonding material (7') is curing to compress the strata (3) surrounding the borehole (1), and then relieving the thrust when the bonding material (7') has cured.
ERIC Educational Resources Information Center
Chen, Haiwen; Holland, Paul
2010-01-01
In this paper, we develop a new curvilinear equating for the nonequivalent groups with anchor test (NEAT) design under the assumption of the classical test theory model, that we name curvilinear Levine observed score equating. In fact, by applying both the kernel equating framework and the mean preserving linear transformation of…
The ACS Exams Institute Undergraduate Chemistry Anchoring Concepts Content Map I: General Chemistry
ERIC Educational Resources Information Center
Holme, Thomas; Murphy, Kristen
2012-01-01
To provide tools for programmatic assessment related to the use of ACS Exams in undergraduate chemistry courses, the ACS Exams Institute has built a content map that applies to the entire undergraduate curriculum. At the top two levels, the grain size of the content classification is large and spans the entire undergraduate curriculum. At the…
Code of Federal Regulations, 2014 CFR
2014-07-01
... CFR 165.10, 165.11, and 165.13 apply within the RNA. (2) In accordance with the general regulations, entry into, anchoring, or movement within the RNA, during periods of enforcement, is prohibited unless... operators of this regulation. (3) During periods of enforcement, entry and movement within the RNA is...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-05
... shares of Anchor Commercial Bank, Juno Beach, Florida. Board of Governors of the Federal Reserve System... FEDERAL RESERVE SYSTEM Change in Bank Control Notices; Acquisitions of Shares of a Bank or Bank Holding Company The notificants listed below have applied under the Change in Bank Control Act (12 U.S.C...
ERIC Educational Resources Information Center
Liu, Jinghua; Sinharay, Sandip; Holland, Paul W.; Feigenbaum, Miriam; Curley, Edward
2009-01-01
This study explores the use of a different type of anchor, a "midi anchor", that has a smaller spread of item difficulties than the tests to be equated, and then contrasts its use with the use of a "mini anchor". The impact of different anchors on observed score equating were evaluated and compared with respect to systematic…
Kang, Yun Gyeong; Kim, Jung-Han; Shin, Jung-Woog; Baik, Jong-Min; Choo, Hye-Jung
2013-11-01
The bioabsorbable suture anchor is probably one of the most commonly used tools in arthroscopic shoulder operations. However, there is controversy about whether the bioabsorbable anchor is replaced by bone. The object of this study is to evaluate bone ingrowth into the micropore bioabsorbable suture anchor and the differences in the biomechanical properties of a micropore anchor and a nonpore anchor. A total of 16 microsized holes (diameter, 250 ± 50 μm; depth, 0.2 mm) were made on the bioabsorbable anchors with a microdrill. Twelve adult New Zealand White rabbits were randomly divided into two groups: group A (n = 6), the nonpore bioabsorbable suture anchor group, and group pA (n = 6), the micropore bioabsorbable suture anchor group. Microcomputed tomography was used at 4 and 8 weeks postoperatively to evaluate ingrowth by bone volume fraction (BVF), which was measured by calculating the ratio of the total volume of bone ingrowth to that of the region of interest. For pullout strength testing, 3 additional rabbits (6 limbs) were used for mechanical testing. The mean BVF was higher in group pA (0.288 ± 0.054) than in group A (0.097 ± 0.006). The micropore anchor had a higher pullout strength (0.520 ± 0.294 N) than the nonpore anchor (0.275 ± 0.064 N). Micropore bioabsorbable suture anchors induced bone ingrowth and showed higher pullout strength, despite processing. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Vashista, Vineet; Khan, Moiz; Agrawal, Sunil K.
2017-01-01
In this paper, we develop an intervention to apply external gait synchronized forces on the pelvis to reduce the user’s effort during walking. A cable-driven robot was used to apply the external forces and an adaptive frequency oscillator scheme was developed to adapt the timing of force actuation to the gait frequency during walking. The external forces were directed in the sagittal plane to assist the trailing leg during the forward propulsion and vertical deceleration of the pelvis during the gait cycle. A pilot experiment with five healthy subjects was conducted. The results showed that the subjects applied lower ground reaction forces in the vertical and anterior-posterior directions during the late stance phase. In summary, the current work provides a novel approach to study the role of external pelvic forces in altering the walking effort. These studies can provide better understanding for designing exoskeletons and prosthetic devices to reduce the overall walking effort. PMID:29623294
Bowman, Shaun M; Piwowar, Amy; Al Dabbous, Mash'el; Vierula, John; Free, Stephen J
2006-03-01
Using mutational and proteomic approaches, we have demonstrated the importance of the glycosylphosphatidylinositol (GPI) anchor pathway for cell wall synthesis and integrity and for the overall morphology of the filamentous fungus Neurospora crassa. Mutants affected in the gpig-1, gpip-1, gpip-2, gpip-3, and gpit-1 genes, which encode components of the N. crassa GPI anchor biosynthetic pathway, have been characterized. GPI anchor mutants exhibit colonial morphologies, significantly reduced rates of growth, altered hyphal growth patterns, considerable cellular lysis, and an abnormal "cell-within-a-cell" phenotype. The mutants are deficient in the production of GPI-anchored proteins, verifying the requirement of each altered gene for the process of GPI-anchoring. The mutant cell walls are abnormally weak, contain reduced amounts of protein, and have an altered carbohydrate composition. The mutant cell walls lack a number of GPI-anchored proteins, putatively involved in cell wall biogenesis and remodeling. From these studies, we conclude that the GPI anchor pathway is critical for proper cell wall structure and function in N. crassa.
Barber, F Alan; Herbert, Morley A; Schroeder, F Alexander; Aziz-Jacobo, Jorge; Mays, Matthew M; Rapley, Jay H
2010-03-01
To evaluate the strength and suture-tendon interface security of various suture anchors triply and doubly loaded with ultrahigh-molecular weight polyethylene-containing sutures and to evaluate the relative effectiveness of placing these anchors in a single-row or double-row arrangement by cyclic loading and then destructive testing. The infraspinatus muscle was reattached to the original humeral footprint by use of 1 of 5 different repair patterns in 40 bovine shoulders. Two single-row repairs and three double-row repairs were tested. High-strength sutures were used for all repairs. Five groups were studied: group 1, 2 triple-loaded screw suture anchors in a single row with simple stitches; group 2, 2 triple-loaded screw anchors in a single row with simple stitches over a fourth suture passed perpendicularly ("rip-stop" stitch); group 3, 2 medial and 2 lateral screw anchors with a single vertical mattress stitch passed from the medial anchors and 2 simple stitches passed from the lateral anchors; group 4, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors capturing the medial sutures in a "crisscross" spanning stitch; and group 5, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors creating a "suture-bridge" stitch. The specimens were cycled between 10 and 180 N at 1.0 Hz for 3,500 cycles or until failure. Endpoints were cyclic loading displacement (5 and 10 mm), total displacement, and ultimate failure load. A single row of triply loaded anchors was more resistant to stretching to a 5- and 10-mm gap than the double-row repairs with or without the addition of a rip-stop suture (P < .05). The addition of a rip-stop stitch made the repair more resistant to gap formation than a double row repair (P < .05). The crisscross double row created by 2 medial double-loaded suture anchors and 2 lateral push-in anchors stretched more than any other group (P < .05). Double-row repairs with either crossing sutures or 4 separate anchor points were more likely to fail (5- or 10-mm gap) than a single-row repair loaded with 3 simple sutures. The triple-loaded anchors with ultrahigh-molecular weight polyethylene-containing sutures placed in a single row were more resistant to stretching than the double-row groups. Copyright 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Lorbach, Olaf; Trennheuser, Christian; Kohn, Dieter; Anagnostakos, Konstantinos
2016-07-01
Biomechanical comparison of three different fixation techniques for a proximal biceps tenodesis. Eighteen human cadaver specimens were used for the testing. A tenodesis of the proximal biceps tendon was performed using a double-loaded suture anchor (5.5-mm Corkscrew, Arthrex), a knotless anchor (5.5-mm SwiveLock, Arthrex) or a forked knotless anchor (8-mm SwiveLock, Arthrex). Reconstructions were cyclically loaded for 50 cycles from 10-60 to 10-100 N. Cyclic displacement and ultimate failure loads were determined, and mode of failure was evaluated. Cyclic displacement at 60 N revealed a mean of 3.3 ± 1.1 mm for the Corkscrew, 5.4 ± 1.4 mm for the 5.5-mm SwiveLock and 2.9 ± 1.6 mm for the 8-mm forked SwiveLock. At 100 N, 5.1 ± 2.2 mm were seen for the Corkscrew anchor, 8.7 ± 2.5 mm for the 5.5-mm SwiveLock and 4.8 ± 3.3 mm for the 8-mm forked SwiveLock anchor. Significant lower cyclic displacement was seen for the Corkscrew anchor (p < 0.020) as well as the 8-mm SwiveLock anchor (p < 0.023) compared to the 5.5-mm SwiveLock anchor at 60 N. An ultimate load to failure of 109 ± 27 N was found for the Corkscrew anchor, 125 ± 25 N were measured for the 5.5-mm SwiveLock anchor, and 175 ± 42 N were found for the 8-mm forked SwiveLock anchor. Significant differences were seen between the 8-mm SwiveLock compared to the 5.5-mm SwiveLock (p < 0.044) as well as the Corkscrew anchor (p < 0.009). No significant differences were seen between the Corkscrew and the 5.5-mm SwiveLock anchor. The new 8-mm forked SwiveLock anchor significantly enhances construct stability compared to a 5.5-mm double-loaded Corkscrew anchor as well as the 5.5-mm SwiveLock suture anchor. However, a restrictive postoperative rehabilitation seems to be important in all tested reconstructions in order to avoid early failure of the construct.
24 CFR 3280.302 - Definitions.
Code of Federal Regulations, 2010 CFR
2010-04-01
... any device or other means designed to transfer home anchoring loads to the ground. Anchoring equipment... means a specific anchoring assembly device designed to transfer home anchoring loads to the ground... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Body and Frame Construction Requirements...
Measures for the Safe Operation of Anchoring in a Storm
NASA Astrophysics Data System (ADS)
Han, Tianding; Ai, Wanzheng
2018-01-01
The collision and stranding of ship other shipwreck accidents are mainly caused by the ship dragging. As the water is less in coastal areas, anchoring has less influence on cementing ship, so strong wind is the most important factor for ship anchoring. Therefore, it is very important to study the safety evaluation of mooring in strong wind. In this paper, the measures taken after the ship anchoring is come up with from the analysis on the typical accidents and causes of anchoring security. The safety measures at the time of anchoring are also studied.
MOEMS Fabry-Pérot interferometer with point-anchored Si-air mirrors for middle infrared
NASA Astrophysics Data System (ADS)
Tuohiniemi, Mikko; Näsilä, Antti; Akujärvi, Altti; Blomberg, Martti
2014-09-01
We studied how a micromachined Fabry-Pérot interferometer, realized with wide point-anchored Si/air-gap reflectors, performs at the middle-infrared. A computational analysis of the anchor mechanical behavior is also presented. Compared with solid-film reflectors, this technology features better index contrast, which enables a wider stop band and potentially higher resolution. In this work, we investigate whether the performance is improved according to the index-contrast benefit, or whether the mechanical differences play a role. For comparison, we manufactured and characterized another design that applies solid-film reflectors of Si/SiO2 structure. This data is exploited as a reference for a middle-infrared interferometer and as a template for mapping the performance from the simulation results to the measured data. The novel Si/air-gap device was realized as a non-tunable proof-of-concept version. The measured data is mapped into an estimate of the achievable performance of a tunable version. We present the measured transmission and resolution data and compare the simulation models that reproduce the data. The prediction for the tunable middle-infrared Si/air-gap device is then presented. The results indicate that the interferometer’s resolution is expected to have improved twofold and have a much wider stop band compared with the prior art.
Noël, Jean-Marc; Sjöberg, Béatrice; Marsac, Rémi; Zigah, Dodzi; Bergamini, Jean-François; Wang, Aifang; Rigaut, Stéphane; Hapiot, Philippe; Lagrost, Corinne
2009-11-03
A versatile two-step method is developed to covalently immobilize redox-active molecules onto carbon surfaces. First, a robust anchoring platform is grafted onto surfaces by electrochemical reduction of aryl diazonium salts in situ generated. Depending on the nature of the layer termini, -COOH or -NH(2), a further chemical coupling involving ferrocenemethylamine or ferrocene carboxylic acid derivatives leads to the covalent binding of ferrocene centers. The chemical strategy using acyl chloride activation is efficient and flexible, since it can be applied either to surface-reactive end groups or to reactive species in solution. Cyclic voltammetry analyses point to the covalent binding of ferrocene units restricted to the upper layers of the underlying aryl films, while AFM measurements show a lost of compactness of the layers after the chemical attachment of ferrocene centers. The preparation conditions of the anchoring layers were found to determine the interfacial properties of the resulted ferrocenyl-modified electrodes. The ferrocene units promoted effective redox mediation providing that the free redox probes are adequately chosen (i.e., vs size/formal potential) and the underlying layers exhibit strong blocking properties. For anchoring films with weaker blocking effect, the coexistence of two distinct phenomena, redox mediation and ET at pinholes could be evidenced.
Zhan, Yu; Yan, Xiaoyu; Xia, Ronggang; Cheng, Tao; Luo, Congfeng
2016-07-01
Syndesmosis injury is common in external-rotation type ankle fractures (ERAF). Trans-syndesmosis screw fixation, the gold-standard treatment, is currently controversial for its complications and biomechanical disadvantages. The purpose of this study was to introduce a new method of anatomically repairing the anterior-inferior tibiofibular ligament (AITFL) and augmentation with anchor rope system to treat the syndesmotic instability in ERAF with posterior malleolus involvement and to compare its clinical outcomes with that of trans-syndesmosis screw fixation. 53 ERAFs with posterior malleolus involvement received surgery, and the syndesmosis was still unstable after fracture fixation. They were randomised into screw fixation group and AITFL anatomical repair with augmentation group. Reduction quality, syndesmosis diastasis recurrence, pain (VAS score), time back to work, Olerud-Molander ankle score and range of motion (ROM) of ankle were investigated. Olerud-Molander score in AITFL repair group and screw group was 90.4 and 85.8 at 12-month follow-up (P>0.05). Plantar flexion was 31.2° and 34.3° in repair and screw groups (P=0.04). Mal-reduction happened in 5 cases (19.2%) in screw group while 2 cases (7.4%) in repair group. Postoperative syndesmosis re-diastasis occurred in 3 cases in screw group while zero in repair group (P>0.05). Pain score was similar between the two groups (P>0.05). Overall complication rate and back to work time were 26.9% and 3.7% (P=0.04), 7.15 months and 5.26 months (P=0.02) in screw group and repair group, respectively. For syndesmotic instability in ERAF with posterior malleolus involvement, the method of AITFL anatomical repair and augmentation with anchor rope system had an equivalent functional outcome and reduction, earlier rehabilitation and less complication compared with screw fixation. It can be selected as an alternative. Copyright © 2016 Elsevier Ltd. All rights reserved.
MASH test 3-37 of the TxDOT 31-inch W-beam downstream anchor terminal.
DOT National Transportation Integrated Search
2011-12-01
The objective of this study was to develop a suitable replacement for the downstream turndown : guardrail anchor system. The turndown guardrail anchor system does not meet mandated test requirements : under MASH for upstream anchor applic...
Application and research of recyclable cables in foundation pit support engineering
NASA Astrophysics Data System (ADS)
Zheng, Suping
2018-05-01
Anchoring cables are widely used in the construction of foundation pit as a temporary support structure. After the construction is completed, the anchor cables left in the ground will not only cause environmental pollution but also cause a great waste of resources. The emergence of recyclable cable technology, to avoid such problems, to achieve the secondary use of the anchor cable, excavation in the excavation project is more and more widely used. Combined with the design and construction of recoverable anchor cable in engineering practice, the application effect of recoverable anchor cable in foundation pit support is analyzed, and the conclusion that the support effect of recoverable anchor cable is stable and safe can be obtained Recyclable anchor cable in the future support projects to provide a reference.
Goschka, Andrew M; Hafer, Jason S; Reynolds, Kirk A; Aberle, Nicholas S; Baldini, Todd H; Hawkins, Monica J; McCarty, Eric C
2015-10-01
To further reduce the invasiveness of arthroscopic rotator cuff repair surgery the all-suture anchor has been developed. The all-suture anchor requires less bone removal and reduces the potential of loose body complications. The all-suture anchor must also have adequate biomechanical strength for the repair to heal. The hypothesis is there is no significant difference in the biomechanical performance of supraspinatus repairs using an all-suture anchor when compared to traditional solid-body suture anchors. Using nine shoulders per group, the supraspinatus tendon was dissected from the greater tuberosity. The four different double row repairs tested were (medial row/lateral row): A: ICONIX2/ICONIX2; B: ICONIX2/Stryker ReelX 3.9mm; C: ICONIX2/Stryker ReelX 4.5mm; D: Arthrex BioComposite CorkScrew FT 4.5mm/Arthrex BioComposite SwiveLock 4.75mm. The ICONIX2 was the only all-suture anchor tested. Tendons underwent cyclic loading from 10 to 100N for 500 cycles, followed by load-to-failure. Data was collected at cycles 5, 100, 200, 300, 400, and 500. One-way ANOVA analysis was used to assess significance (P≤0.05). The anchor combinations tested did not differ significantly in anterior (P>0.4) or posterior (P>0.3) gap formation, construct stiffness (P>0.7), ultimate load (P=0.06), or load to 5mm gap formation (P=0.84). The all-suture anchor demonstrated comparable biomechanical performance in multiple double-row anchor combinations to a combination of traditional solid-body anchors. Thus it may be an attractive option to further reduce the invasiveness of rotator cuff repairs. Copyright © 2015 Elsevier Ltd. All rights reserved.
Corroded Anchor Structure Stability/Reliability (CAS_Stab-R) Software for Hydraulic Structures
2017-12-01
This report describes software that provides a probabilistic estimate of time -to-failure for a corroding anchor strand system. These anchor...stability to the structure. A series of unique pull-test experiments conducted by Ebeling et al. (2016) at the U.S. Army Engineer Research and...Reliability (CAS_Stab-R) produces probabilistic Remaining Anchor Life time estimates for anchor cables based upon the direct corrosion rate for the
Lenis, Vasileios Panagiotis E; Swain, Martin; Larkin, Denis M
2018-05-01
Cross-species whole-genome sequence alignment is a critical first step for genome comparative analyses, ranging from the detection of sequence variants to studies of chromosome evolution. Animal genomes are large and complex, and whole-genome alignment is a computationally intense process, requiring expensive high-performance computing systems due to the need to explore extensive local alignments. With hundreds of sequenced animal genomes available from multiple projects, there is an increasing demand for genome comparative analyses. Here, we introduce G-Anchor, a new, fast, and efficient pipeline that uses a strictly limited but highly effective set of local sequence alignments to anchor (or map) an animal genome to another species' reference genome. G-Anchor makes novel use of a databank of highly conserved DNA sequence elements. We demonstrate how these elements may be aligned to a pair of genomes, creating anchors. These anchors enable the rapid mapping of scaffolds from a de novo assembled genome to chromosome assemblies of a reference species. Our results demonstrate that G-Anchor can successfully anchor a vertebrate genome onto a phylogenetically related reference species genome using a desktop or laptop computer within a few hours and with comparable accuracy to that achieved by a highly accurate whole-genome alignment tool such as LASTZ. G-Anchor thus makes whole-genome comparisons accessible to researchers with limited computational resources. G-Anchor is a ready-to-use tool for anchoring a pair of vertebrate genomes. It may be used with large genomes that contain a significant fraction of evolutionally conserved DNA sequences and that are not highly repetitive, polypoid, or excessively fragmented. G-Anchor is not a substitute for whole-genome aligning software but can be used for fast and accurate initial genome comparisons. G-Anchor is freely available and a ready-to-use tool for the pairwise comparison of two genomes.
AnchorDock: Blind and Flexible Anchor-Driven Peptide Docking.
Ben-Shimon, Avraham; Niv, Masha Y
2015-05-05
The huge conformational space stemming from the inherent flexibility of peptides is among the main obstacles to successful and efficient computational modeling of protein-peptide interactions. Current peptide docking methods typically overcome this challenge using prior knowledge from the structure of the complex. Here we introduce AnchorDock, a peptide docking approach, which automatically targets the docking search to the most relevant parts of the conformational space. This is done by precomputing the free peptide's structure and by computationally identifying anchoring spots on the protein surface. Next, a free peptide conformation undergoes anchor-driven simulated annealing molecular dynamics simulations around the predicted anchoring spots. In the challenging task of a completely blind docking test, AnchorDock produced exceptionally good results (backbone root-mean-square deviation ≤ 2.2Å, rank ≤15) for 10 of 13 unbound cases tested. The impressive performance of AnchorDock supports a molecular recognition pathway that is driven via pre-existing local structural elements. Copyright © 2015 Elsevier Ltd. All rights reserved.
Research on discrete element simulation of anchor frame beam reinforcement in bedding shale slope
NASA Astrophysics Data System (ADS)
Zhang, Xiao yong; Xie, Xiao ting
2017-11-01
The anchor frame beam is a new type of composite support method, which is a kind of slope protection structure considering the interaction between the anchors and the slope. Based on the reinforcement project of a bedding shale slope in Chengzhang highway, the reinforced effect of anchor frame beam is studied by discrete element method. Firstly, the mesoscopic parameters of the rock mass are obtained by calibration while that of anchor frame beam are obtained by calculation. Then the slope model with the reinforcement of anchor frame beam is established by particle flow software PFC2D. Afterwards, the statement of slope can be analyzed and the reinforcement effect of anchor frame beam can be predicted. Results show that: there is no instability in the slope after reinforcement, and the sliding of slope can be effectively prevented by anchor frame beam. The simulation results can provide reference for the design and construction of the project.
NASA Astrophysics Data System (ADS)
Basu, Rajratan
2017-07-01
A small quantity of monolayer graphene flakes is doped in a nematic liquid crystal (LC), and the effective polar anchoring strength coefficient between the LC and the alignment substrate is found to increase by an order of magnitude. The hexagonal pattern of graphene can interact with the LC's benzene rings via π -π electron stacking, enabling the LC to anchor to the graphene surface homogeneously (i.e., planar anchoring). When the LC cell is filled with the graphene-doped LC, some graphene flakes are preferentially attached to the alignment layer and modify the substrate's anchoring property. These spontaneously deposited graphene flakes promote planar anchoring at the substrate and the polar anchoring energy at alignment layer is enhanced significantly. The enhanced anchoring energy is found to impact favorably on the electro-optic response of the LC. Additional studies reveal that the nematic electro-optic switching is significantly faster in the LC-graphene hybrid than that of the pure LC.
Anchor-Free Localization Method for Mobile Targets in Coal Mine Wireless Sensor Networks
Pei, Zhongmin; Deng, Zhidong; Xu, Shuo; Xu, Xiao
2009-01-01
Severe natural conditions and complex terrain make it difficult to apply precise localization in underground mines. In this paper, an anchor-free localization method for mobile targets is proposed based on non-metric multi-dimensional scaling (Multi-dimensional Scaling: MDS) and rank sequence. Firstly, a coal mine wireless sensor network is constructed in underground mines based on the ZigBee technology. Then a non-metric MDS algorithm is imported to estimate the reference nodes’ location. Finally, an improved sequence-based localization algorithm is presented to complete precise localization for mobile targets. The proposed method is tested through simulations with 100 nodes, outdoor experiments with 15 ZigBee physical nodes, and the experiments in the mine gas explosion laboratory with 12 ZigBee nodes. Experimental results show that our method has better localization accuracy and is more robust in underground mines. PMID:22574048
Anchor-free localization method for mobile targets in coal mine wireless sensor networks.
Pei, Zhongmin; Deng, Zhidong; Xu, Shuo; Xu, Xiao
2009-01-01
Severe natural conditions and complex terrain make it difficult to apply precise localization in underground mines. In this paper, an anchor-free localization method for mobile targets is proposed based on non-metric multi-dimensional scaling (Multi-dimensional Scaling: MDS) and rank sequence. Firstly, a coal mine wireless sensor network is constructed in underground mines based on the ZigBee technology. Then a non-metric MDS algorithm is imported to estimate the reference nodes' location. Finally, an improved sequence-based localization algorithm is presented to complete precise localization for mobile targets. The proposed method is tested through simulations with 100 nodes, outdoor experiments with 15 ZigBee physical nodes, and the experiments in the mine gas explosion laboratory with 12 ZigBee nodes. Experimental results show that our method has better localization accuracy and is more robust in underground mines.
NASA Astrophysics Data System (ADS)
Kardanpour, Reihaneh; Tangestaninejad, Shahram; Mirkhani, Valiollah; Moghadam, Majid; Mohammadpoor-Baltork, Iraj; Zadehahmadi, Farnaz
2016-03-01
Efficient synthesis of various benzimidazoles and benzothiazoles under mild conditions catalyzed by Cu(II) anchored onto UiO-66-NH2 metal organic framework is reported. In this manner, first, the aminated UiO-66 was modified with thiophene-2-carbaldehyde and then the prepared Schiff base was reacted with CuCl2. The prepared catalyst was characterized by FT-IR, UV-vis, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), N2 adsorption, inductively coupled plasma atomic emission spectroscopy (ICP-AES) and field emission scanning electron microscopy (FE-SEM). The UiO-66-NH2-TC-Cu was applied as a highly efficient catalyst for synthesis of benzimidazole and benzothiazole derivatives by the reaction of aldehydes with 1,2-diaminobenzene or 2-aminothiophenol. The Cu(II)-containing MOF was reused several times without any appreciable loss of its efficiency.
NASA Astrophysics Data System (ADS)
Carette, Noëlle; Engelkamp, Hans; Akpa, Eric; Pierre, Sebastien J.; Cameron, Neil R.; Christianen, Peter C. M.; Maan, Jan C.; Thies, Jens C.; Weberskirch, Ralf; Rowan, Alan E.; Nolte, Roeland J. M.; Michon, Thierry; van Hest, Jan C. M.
2007-04-01
Virus particles are probably the most precisely defined nanometre-sized objects that can be formed by protein self-assembly. Although their natural function is the storage and transport of genetic material, they have more recently been applied as scaffolds for mineralization and as containers for the encapsulation of inorganic compounds. The reproductive power of viruses has been used to develop versatile analytical methods, such as phage display, for the selection and identification of (bio)active compounds. To date, the combined use of self-assembly and reproduction has not been used for the construction of catalytic systems. Here we describe a self-assembled system based on a plant virus that has its coat protein genetically modified to provide it with a lipase enzyme. Using single-object and bulk catalytic studies, we prove that the virus-anchored lipase molecules are catalytically active. This anchored biocatalyst, unlike man-made supported catalysts, has the capability to reproduce itself in vivo, generating many independent catalytically active copies.
ChromA: signal-based retention time alignment for chromatography-mass spectrometry data.
Hoffmann, Nils; Stoye, Jens
2009-08-15
We describe ChromA, a web-based alignment tool for chromatography-mass spectrometry data from the metabolomics and proteomics domains. Users can supply their data in open and standardized file formats for retention time alignment using dynamic time warping with different configurable local distance and similarity functions. Additionally, user-defined anchors can be used to constrain and speedup the alignment. A neighborhood around each anchor can be added to increase the flexibility of the constrained alignment. ChromA offers different visualizations of the alignment for easier qualitative interpretation and comparison of the data. For the multiple alignment of more than two data files, the center-star approximation is applied to select a reference among input files to align to. ChromA is available at http://bibiserv.techfak.uni-bielefeld.de/chroma. Executables and source code under the L-GPL v3 license are provided for download at the same location.
Charge transfer at organic-inorganic interfaces—Indoline layers on semiconductor substrates
NASA Astrophysics Data System (ADS)
Meyenburg, I.; Falgenhauer, J.; Rosemann, N. W.; Chatterjee, S.; Schlettwein, D.; Heimbrodt, W.
2016-12-01
We studied the electron transfer from excitons in adsorbed indoline dye layers across the organic-inorganic interface. The hybrids consist of indoline derivatives on the one hand and different inorganic substrates (TiO2, ZnO, SiO2(0001), fused silica) on the other. We reveal the electron transfer times from excitons in dye layers to the organic-inorganic interface by analyzing the photoluminescence transients of the dye layers after femtosecond excitation and applying kinetic model calculations. A correlation between the transfer times and four parameters have been found: (i) the number of anchoring groups, (ii) the distance between the dye and the organic-inorganic interface, which was varied by the alkyl-chain lengths between the carboxylate anchoring group and the dye, (iii) the thickness of the adsorbed dye layer, and (iv) the level alignment between the excited dye ( π* -level) and the conduction band minimum of the inorganic semiconductor.
Clathrin-independent pathways do not contribute significantly to endocytic flux.
Bitsikas, Vassilis; Corrêa, Ivan R; Nichols, Benjamin J
2014-09-17
Several different endocytic pathways have been proposed to function in mammalian cells. Clathrin-coated pits are well defined, but the identity, mechanism and function of alternative pathways have been controversial. Here we apply universal chemical labelling of plasma membrane proteins to define all primary endocytic vesicles, and labelling of specific proteins with a reducible SNAP-tag substrate. These approaches provide high temporal resolution and stringent discrimination between surface-connected and intracellular membranes. We find that at least 95% of the earliest detectable endocytic vesicles arise from clathrin-coated pits. GPI-anchored proteins, candidate cargoes for alternate pathways, are also found to enter the cell predominantly via coated pits. Experiments employing a mutated clathrin adaptor reveal distinct mechanisms for sorting into coated pits, and thereby explain differential effects on the uptake of transferrin and GPI-anchored proteins. These data call for a revision of models for the activity and diversity of endocytic pathways in mammalian cells.
[Functional anatomy of the male continence mechanism].
Schwalenberg, T; Neuhaus, J; Dartsch, M; Weissenfels, P; Löffler, S; Stolzenburg, J-U
2010-04-01
The basic structures and organs contributing to continence in men are far less well investigated than in women. This concerns anatomical and functional aspects as well. Especially the cooperation of single components and the dynamic anchoring in the pelvic floor require further investigation. An improved anatomical-functional interpretation is needed to generate therapeutic concepts orientated at the physiology of the bladder neck.Therefore, the focus of anatomical investigations should be on the external sphincter which is the main muscle responsible for urethral closure as well as on the connective tissue, smooth muscular and neuronal structures in the pelvis. The smooth muscular structures involved are the internal sphincter, the inner parts of the external sphincter, the urethral longitudinal musculature, and parts of the centrum perinei and of the ventral suspension apparatus which fixes the position of the bladder neck and seems to be vital for continence and initiation of micturition. These new findings imply an integral concept for men as was developed for women. A first step in this regard would be a consistent and updated anatomical nomenclature.
Kim, Mikyung; Song, Likai; Moon, James; Sun, Zhen-Yu J.; Bershteyn, Anna; Hanson, Melissa; Cain, Derek; Goka, Selasie; Kelsoe, Garnett; Wagner, Gerhard; Irvine, Darrell; Reinherz, Ellis L.
2013-01-01
Structural characterization of epitope-paratope pairs has contributed to the understanding of antigenicity. By contrast, few structural studies relate to immunogenicity, the process of antigen-induced immune responses in vivo. Using a lipid-arrayed membrane-proximal external region (MPER) of HIV-1 glycoprotein 41 as a model antigen, we investigated the influence of physicochemical properties on immunogenicity in relation to structural modifications of MPER/liposome vaccines. Anchoring the MPER to the membrane via an alkyl tail or transmembrane domain retained the MPER on liposomes in vivo, while preserving MPER secondary structure. However, structural modifications that affected MPER membrane orientation and antigenic residue accessibility strongly impacted induced antibody responses. The solvent-exposed MPER tryptophan residue (Trp-680) was immunodominant, focusing immune responses, despite sequence variability elsewhere. Nonetheless, immunogenicity could be readily manipulated using site-directed mutagenesis or structural constraints to modulate amino acid surface display. These studies provide fundamental insights for immunogen design aimed at targeting B cell antibody responses. PMID:24047898
Lewis, Tyler; Esler, Daniel N.; Uher-Koch, Brian D.; Dickson, Rian D.; Anderson, Eric M.; Evenson, Joseph R.; Hupp, Jerry W.; Flint, Paul L.
2017-01-01
A major challenge of wildlife telemetry is choosing an attachment technique that maximizes transmitter retention while minimizing negative side effects. For waterbirds, attachment of transmitters with subcutaneous anchors has been an effective and well-established technique, having been used on >40 species. This method was recently modified to include a second subcutaneous anchor, presumably increasing transmitter retention beyond that of single-anchor attachments. This putative benefit may be offset, however, by increased health risks related to additional incisions and subcutaneous protrusions. To test this potential trade-off, we attached radiotransmitters to molting and wintering surf (Melanitta perspicillata) and white-winged scoters (M. fusca) during 2008 and 2009 in Washington State and southeast Alaska, USA, using single- (121 scoters) and double-anchor (128 scoters) attachment techniques. We estimated daily probabilities of survival and radio retention for each group, this being apparent retention for wintering scoters because we could not differentiate shed transmitters from flighted emigration. For scoters during the flightless remigial molt, we found that addition of a second anchor increased cumulative retention probability (±SE) over a 49-day period from 0.69 ± 0.11 for single-anchor to 0.88 ± 0.07 for double-anchor attachments, while having no effect on survival. However, during winter, scoters with double-anchor attachments experienced no improvement in apparent retention, while having significantly lower survival during their first 14 days following transmitter attachment; of 15 mortalities during this period, 11 had 2 subcutaneous anchors. From day 15 onward, winter survival rates were nearly identical for single- versus double-anchor attachments, indicating that adverse effects of subcutaneous anchors were mainly limited to the 14-day postattachment period. Overall, given that the survival cost of adding a second subcutaneous anchor was substantial for wintering scoters—decreasing 14-day survival by 12% for adults and 23% for juveniles—we recommend that researchers opt for single-anchor attachments under most circumstances, especially during winter when birds may be energetically challenged.
Gardiner, Jack; Schroeder, Steven; Polacco, Mary L.; Sanchez-Villeda, Hector; Fang, Zhiwei; Morgante, Michele; Landewe, Tim; Fengler, Kevin; Useche, Francisco; Hanafey, Michael; Tingey, Scott; Chou, Hugh; Wing, Rod; Soderlund, Carol; Coe, Edward H.
2004-01-01
Our goal is to construct a robust physical map for maize (Zea mays) comprehensively integrated with the genetic map. We have used a two-dimensional 24 × 24 overgo pooling strategy to anchor maize expressed sequence tagged (EST) unigenes to 165,888 bacterial artificial chromosomes (BACs) on high-density filters. A set of 70,716 public maize ESTs seeded derivation of 10,723 EST unigene assemblies. From these assemblies, 10,642 overgo sequences of 40 bp were applied as hybridization probes. BAC addresses were obtained for 9,371 overgo probes, representing an 88% success rate. More than 96% of the successful overgo probes identified two or more BACs, while 5% identified more than 50 BACs. The majority of BACs identified (79%) were hybridized with one or two overgos. A small number of BACs hybridized with eight or more overgos, suggesting that these BACs must be gene rich. Approximately 5,670 overgos identified BACs assembled within one contig, indicating that these probes are highly locus specific. A total of 1,795 megabases (Mb; 87%) of the total 2,050 Mb in BAC contigs were associated with one or more overgos, which are serving as sequence-tagged sites for single nucleotide polymorphism development. Overgo density ranged from less than one overgo per megabase to greater than 20 overgos per megabase. The majority of contigs (52%) hit by overgos contained three to nine overgos per megabase. Analysis of approximately 1,022 Mb of genetically anchored BAC contigs indicates that 9,003 of the total 13,900 overgo-contig sites are genetically anchored. Our results indicate overgos are a powerful approach for generating gene-specific hybridization probes that are facilitating the assembly of an integrated genetic and physical map for maize. PMID:15020742
Ghosh, Dwaipayan; Febriansyah, Benny; Gupta, Disha; Ng, Leonard Kia-Sheun; Xi, Shibo; Du, Yonghua; Baikie, Tom; Dong, ZhiLi; Soo, Han Sen
2018-05-22
Catalyst deactivation is a persistent problem not only for the scientific community but also in industry. Isolated single-site heterogeneous catalysts have shown great promise to overcome these problems. Here, a versatile anchoring strategy for molecular complex immobilization on a broad range of semiconducting or insulating metal oxide ( e. g., titanium dioxide, mesoporous silica, cerium oxide, and tungsten oxide) nanoparticles to synthesize isolated single-site catalysts has been studied systematically. An oxidatively stable anchoring group, maleimide, is shown to form covalent linkages with surface hydroxyl functionalities of metal oxide nanoparticles by photoclick chemistry. The nanocomposites have been thoroughly characterized by techniques including UV-visible diffuse reflectance spectroscopy, high-resolution transmission electron microscopy, X-ray photoelectron spectroscopy, infrared spectroscopy, and X-ray absorption spectroscopy (XAS). The IR spectroscopic studies confirm the covalent linkages between the maleimide group and surface hydroxyl functionalities of the oxide nanoparticles. The hybrid nanomaterials function as highly efficient catalysts for essentially quantitative oxidations of terminal and internal alkenes and show molecular catalyst product selectivities even in more eco-friendly solvents. XAS studies verify the robustness of the catalysts after several catalytic cycles. We have applied the photoclick anchoring methodology to precisely control the deposition of a luminescent variant of our catalyst on the metal oxide nanoparticles. Overall, we demonstrate a general approach to use irradiation to anchor molecular complexes on oxide nanoparticles to create recyclable, hybrid, single-site catalysts that function with high selectivity in a broad range of solvents. We have achieved a facile, spatially and temporally controllable photoclick method that can potentially be extended to other ligands, catalysts, functional molecules, and surfaces.
Model test of anchoring effect on zonal disintegration in deep surrounding rock masses.
Chen, Xu-Guang; Zhang, Qiang-Yong; Wang, Yuan; Liu, De-Jun; Zhang, Ning
2013-01-01
The deep rock masses show a different mechanical behavior compared with the shallow rock masses. They are classified into alternating fractured and intact zones during the excavation, which is known as zonal disintegration. Such phenomenon is a great disaster and will induce the different excavation and anchoring methodology. In this study, a 3D geomechanics model test was conducted to research the anchoring effect of zonal disintegration. The model was constructed with anchoring in a half and nonanchoring in the other half, to compare with each other. The optical extensometer and optical sensor were adopted to measure the displacement and strain changing law in the model test. The displacement laws of the deep surrounding rocks were obtained and found to be nonmonotonic versus the distance to the periphery. Zonal disintegration occurs in the area without anchoring and did not occur in the model under anchoring condition. By contrasting the phenomenon, the anchor effect of restraining zonal disintegration was revealed. And the formation condition of zonal disintegration was decided. In the procedure of tunnel excavation, the anchor strain was found to be alternation in tension and compression. It indicates that anchor will show the nonmonotonic law during suppressing the zonal disintegration.
Model Test of Anchoring Effect on Zonal Disintegration in Deep Surrounding Rock Masses
Chen, Xu-Guang; Zhang, Qiang-Yong; Wang, Yuan; Liu, De-Jun; Zhang, Ning
2013-01-01
The deep rock masses show a different mechanical behavior compared with the shallow rock masses. They are classified into alternating fractured and intact zones during the excavation, which is known as zonal disintegration. Such phenomenon is a great disaster and will induce the different excavation and anchoring methodology. In this study, a 3D geomechanics model test was conducted to research the anchoring effect of zonal disintegration. The model was constructed with anchoring in a half and nonanchoring in the other half, to compare with each other. The optical extensometer and optical sensor were adopted to measure the displacement and strain changing law in the model test. The displacement laws of the deep surrounding rocks were obtained and found to be nonmonotonic versus the distance to the periphery. Zonal disintegration occurs in the area without anchoring and did not occur in the model under anchoring condition. By contrasting the phenomenon, the anchor effect of restraining zonal disintegration was revealed. And the formation condition of zonal disintegration was decided. In the procedure of tunnel excavation, the anchor strain was found to be alternation in tension and compression. It indicates that anchor will show the nonmonotonic law during suppressing the zonal disintegration. PMID:23997683
A comparison of lateral ankle ligament suture anchor strength.
Barber, F Alan; Herbert, Morley A; Crates, John M
2013-06-01
Lateral ankle ligament repairs increasingly use suture anchors instead of bone tunnels. Our purpose was to compare the biomechanical properties of a knotted and knotless suture anchor appropriate for a lateral ankle ligament reconstruction. In porcine distal fibulae, 10 samples of 2 different PEEK anchors were inserted. The attached sutures were cyclically loaded between 10N and 60N for 200 cycles. A destructive pull was performed and failure loads, cyclic displacement, stiffness, and failure mode recorded. PushLock 2.5 anchors failed before 200 cycles. PushLock 100 cycle displacement was less than Morphix 2.5 displacement (p<0.001). Ultimate failure load for anchors completing 200 cycles was 86.5N (PushLock) and 252.1N (Morphix) (p<0.05). The failure mode was suture breaking for all PushLocks while the Morphix failed equally by anchor breaking and suture breakage. The knotted Morphix demonstrated more displacement and greater failure strength than the knotless PushLock. The PushLock failed consistently with suture breaking. The Morphix anchor failed both by anchor breaking and by suture breaking. Copyright © 2012 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Bowman, Shaun M.; Piwowar, Amy; Al Dabbous, Mash'el; Vierula, John; Free, Stephen J.
2006-01-01
Using mutational and proteomic approaches, we have demonstrated the importance of the glycosylphosphatidylinositol (GPI) anchor pathway for cell wall synthesis and integrity and for the overall morphology of the filamentous fungus Neurospora crassa. Mutants affected in the gpig-1, gpip-1, gpip-2, gpip-3, and gpit-1 genes, which encode components of the N. crassa GPI anchor biosynthetic pathway, have been characterized. GPI anchor mutants exhibit colonial morphologies, significantly reduced rates of growth, altered hyphal growth patterns, considerable cellular lysis, and an abnormal “cell-within-a-cell” phenotype. The mutants are deficient in the production of GPI-anchored proteins, verifying the requirement of each altered gene for the process of GPI-anchoring. The mutant cell walls are abnormally weak, contain reduced amounts of protein, and have an altered carbohydrate composition. The mutant cell walls lack a number of GPI-anchored proteins, putatively involved in cell wall biogenesis and remodeling. From these studies, we conclude that the GPI anchor pathway is critical for proper cell wall structure and function in N. crassa. PMID:16524913
Moraes, Renato; Bedo, Bruno L. S.; Santos, Luciana O.; Batistela, Rosangela A.; Santiago, Paulo R. P.; Mauerberg-deCastro, Eliane
2018-01-01
This study investigated the effect of adding haptic information to the control of posture, as well as comparing the effect of both the “light touch” (LT) and “anchor system” (AS) paradigms on postural sway. Additionally, it compared the effect of location and number of points of contact to the control of posture in young adults. The location consisted of using the anchors tied to the finger and held by the hands, and, for LT, the fingertip. For the number of points of contact, participants used two hands, and then separately the dominant hand, and the non-dominant hand, for both anchor and LT paradigms. Participants stood upright with feet-together and in tandem position while performing tasks that combined the use of anchors and LT, points of contact (hand grip and finger), and number of points of contact (two hands and one hand). In this study, the anchors consist of holding in each hand a flexible cable with the other end attached to the ground. The LT consists of slightly touching a rigid surface with the tip of the index finger. The results showed, first, that the anchors improved postural control less than did the LT. Second, they revealed that holding the anchors with the hands or with them tied to the fingertip resulted in a similar reduction in postural sway only in the tandem position. For the feet-together position, the anchors tied to the fingertip were ineffective. Similarly, the use of one or two hands did not affect the contribution of the anchors. However, using two hands in the LT condition was more effective than was one hand. Third, our results showed the presence of a temporal delay between force and center-of-pressure (COP) for the anchors, only in the AP direction with feet-together. In conclusion, overall, the anchors were less effective in reducing postural sway than was the LT. The anchors attached to fingertips were as effective as the hand-held anchors in the tandem position, yet ineffective during foot-together standing. Force-COP timing explains reduced postural sway with LT but not for the anchor; hence, exploratory and supra-postural components may be involved. PMID:29922122
49 CFR 192.461 - External corrosion control: Protective coating.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false External corrosion control: Protective coating... for Corrosion Control § 192.461 External corrosion control: Protective coating. (a) Each external protective coating, whether conductive or insulating, applied for the purpose of external corrosion control...
49 CFR 192.461 - External corrosion control: Protective coating.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false External corrosion control: Protective coating... for Corrosion Control § 192.461 External corrosion control: Protective coating. (a) Each external protective coating, whether conductive or insulating, applied for the purpose of external corrosion control...
Conventional Anchor Test Results at San Diego and Indian Island
1980-07-01
operational practicality of using the Stockless anchor with welded open flukes, since tests have indicated higher capac- ities for the anchor with...Tests (Ref 1) of the Stockless anchor in mud with flukes free-swinging and with flukes welded open show significant increase.s in efficiency for the...latter condition, 4 versus 2, indicating that the anchor flukes did not open completely or at all for the free swinging (usual) condition. Towne (Ref 1
HKUST-1 Membranes Anchored on Porous Substrate by Hetero MIL-110 Nanorod Array Seeds.
Mao, Yiyin; Cao, Wei; Li, Junwei; Sun, Luwei; Peng, Xinsheng
2013-09-02
Great anchors and seeds: Hetero-seeding growth processes and anchored nanorod arrays were successfully utilized in the synthesis of HKUST-1 membranes. These arrays were firmly anchored on porous substrates by using a MIL-110 nanorod array as both the anchor and seed. The resulting HKUST-1 membranes demonstrated good separation factors for binary gases exceeding the Knudson selectivity. Copyright © 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim.
Costa, Andréia Abud da Silva; Manciopi, Priscila Abbári Rossi; Mauerberg-deCastro, Eliane; Moraes, Renato
2015-11-16
This study assessed whether the use of an "anchor system" benefited older adults who performed a tandem walking task. Additionally, we tested the effects of practice with the anchor system during walking on trunk stability, in the frontal plane, of older adults. Forty-four older adults were randomly assigned to three groups: control group, 0g anchor group, and 125g anchor group. Individuals in each group performed a tandem walking task on the GaitRite system with an accelerometer placed on the cervical region. The participants in the 125g anchor group held, in each hand, a flexible cable with a light mass attached at the end of the cable, which rested on the ground. While the participants walked, they pulled on the cables just enough to keep them taut as the masses slid over the ground. The 0g anchor group held an anchor tool without any mass attached to the end portion. The results of this study demonstrated that the use of the anchor system contributed to the reduction of trunk acceleration in the frontal plane. However, this effect did not persist after removal of the anchors, which suggests that the amount of practice with this tool was insufficient to generate any lasting effect, or that the task was not sufficiently challenging, or both. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Career anchors of dentist leaders.
Tuononen, Tiina; Lammintakanen, Johanna; Suominen, Anna Liisa
2016-08-01
The work of a health care leader is demanding; in order to cope, leaders need motivation and support. The occurrence of intrinsic factors called career anchors (combination of one's competence, motives and values) could be a contributing factor in dentist leaders' career decisions. The aim of our study was to identify dentist leaders' career anchors and their association to dentist leaders' retention or turnover of the leadership position. Materials were gathered in 2014 via an electronic questionnaire from 156 current (Leaders) or former (Leavers) Finnish dentist leaders. Career anchor evaluation was conducted by the questionnaire and scoring-table taken from Edgar Schein's Career Anchors Self-Assessment. Both the most and the least important career anchors were detected by the highest and lowest scores and their occurrence reported as percentages. Associations between career anchor scores and tendency to stay were analyzed with logistic regression. 'Technical/Functional Competence' and 'Lifestyle' were most frequently reported as the most important and 'Entrepreneurial Creativity' and 'General Managerial Competence' as the least important career anchors. However, a higher level of 'General Managerial Competence' anchor was most significantly associated with staying in a leadership position. Instead, 'Pure Challenge' and 'Lifestyle' decreased the odds to stay. The knowledge of the important and essential career anchors of dentist leaders' and individuals' could perform crucial part in career choices and also in planning education, work opportunities and human resource policies promoting retention of dentist leaders and probably also other health care leaders.
Liquid crystal dynamic flow control by bidirectional alignment surface
NASA Astrophysics Data System (ADS)
Li, Y. W.; Lee, C. Y.; Kwok, H. S.
2009-02-01
We investigate the behavior of liquid crystal dynamic flow in a cell with a bidirectional alignment (BDA) surface. Numerical simulations show that with a BDA surface having a pitch comparable to the cell gap d, the liquid crystal dynamic flow direction can be controlled by the driving voltage. Such an effect can be applied to bistable twisted nematic displays without the need for anchoring breaking.
ERIC Educational Resources Information Center
Choi, Sae Il
2009-01-01
This study used simulation (a) to compare the kernel equating method to traditional equipercentile equating methods under the equivalent-groups (EG) design and the nonequivalent-groups with anchor test (NEAT) design and (b) to apply the parametric bootstrap method for estimating standard errors of equating. A two-parameter logistic item response…
ERIC Educational Resources Information Center
Ramakrishna, Hindupur V.; Potosky, Denise
2003-01-01
Information systems professionals (n=163) completed measures of career anchors and outcomes (career/job satisfaction, job performance, perceived advancement prospects); 46% had multiple dominant anchors and these individuals did not have significantly different career outcomes than those with single dominant anchors. (Contains 26 references.) (SK)
NASA Astrophysics Data System (ADS)
Zainal, Israa G.; Al-Shammari, Ahmed Majeed; Kachi, Wjeah
2018-05-01
Surface functionalization of magnetic iron oxide nanoparticles (NPs) is a kind of functional materials, which have been widely used in the biotechnology and catalysis. In this study, Nickel-Zinc ferrite nanoparticles was functionalized with amino propyl triethoxy silane (APTES) by silanization reaction and both non coated and organosilane-coated magnetite characterized by energy-dispersive X-ray spectroscopy (EDX), X-ray diffractometry, Fourier transformed infrared spectroscopy (FTIR) and atomic force microscopy. Basic groups of amino anchored on the external surface of the coated magnetite were observed. Our study procedure nanoparticles which have surface with free - NH2 groups which can carry out ionic interaction with carboxylic groups and act as a carrier of biological molecules, drugs and metals.
The place of white in a world of grays: a double-anchoring theory of lightness perception.
Bressan, Paola
2006-07-01
The specific gray shades in a visual scene can be derived from relative luminance values only when an anchoring rule is followed. The double-anchoring theory I propose in this article, as a development of the anchoring theory of Gilchrist et al. (1999), assumes that any given region (a) belongs to one or more frameworks, created by Gestalt grouping principles, and (b) is independently anchored, within each framework, to both the highest luminance and the surround luminance. The region's final lightness is a weighted average of the values computed, relative to both anchors, in all frameworks. The new model accounts not only for all lightness illusions that are qualitatively explained by the anchoring theory but also for a number of additional effects, and it does so quantitatively, with the support of mathematical simulations. ((c) 2006 APA, all rights reserved).
Students' Anchoring Predisposition: An Illustration from Spring Training Baseball
ERIC Educational Resources Information Center
Mohrweis, Lawrence C.
2014-01-01
The anchoring tendency results when decision makers anchor on initial values and then make final assessments that are adjusted insufficiently away from the initial values. The professional literature recognizes that auditors often risk falling into the judgment trap of anchoring and adjusting (Ranzilla et al., 2011). Students may also be unaware…
46 CFR 108.705 - Anchors, chains, wire rope, and hawsers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Anchors, chains, wire rope, and hawsers. 108.705 Section... UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.705 Anchors, chains, wire rope, and hawsers. (a) Each unit must be fitted with anchors, chains, wire rope, and hawsers in agreement with the standards...
46 CFR 108.705 - Anchors, chains, wire rope, and hawsers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Anchors, chains, wire rope, and hawsers. 108.705 Section... UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.705 Anchors, chains, wire rope, and hawsers. (a) Each unit must be fitted with anchors, chains, wire rope, and hawsers in agreement with the standards...
Anchoring effects in the judgment of confidence: semantic or numeric priming?
Carroll, Steven R; Petrusic, William M; Leth-Steensen, Craig
2009-02-01
Over the last decade, researchers have debated whether anchoring effects are the result of semantic or numeric priming. The present study tested both hypotheses. In four experiments involving a sensory detection task, participants first made a relative confidence judgment by deciding whether they were more or less confident than an anchor value in the correctness of their decision. Subsequently, they expressed an absolute level of confidence. In two of these experiments, the relative confidence anchor values represented the midpoints between the absolute confidence scale values, which were either explicitly numeric or semantic, nonnumeric representations of magnitude. In two other experiments, the anchor values were drawn from a scale modally different from that used to express the absolute confidence (i.e., nonnumeric and numeric, respectively, or vice versa). Regardless of the nature of the anchors, the mean confidence ratings revealed anchoring effects only when the relative and absolute confidence values were drawn from identical scales. Together, the results of these four experiments limit the conditions under which both numeric and semantic priming would be expected to lead to anchoring effects.
Supramolecular engineering of carbon nanostructures
NASA Astrophysics Data System (ADS)
Jian, Kengqing
This thesis identifies a new and flexible route to control graphene layer structure in carbons, which is the key to carbon properties and applications, and focuses on the synthesis, structure-property relationships, and potential applications of new "supramolecular" carbon nanomaterials. This new approach begins with the studies of surface anchoring and assembly mechanisms among planar discotic liquid crystals. The results show that disk-like polyaromatics exhibit weak noncovalent interactions with most surfaces and prefer edge-on anchoring at these surfaces; only on a few surfaces such as graphite and platinum, they prefer face-on anchoring. A theory of pi-pi bond preservation has been proposed to explain the wetting, anchoring, and assembly phenomena. Based on the assembly study, a supramolecular approach was developed, which uses surfaces, flows, and confinement to create well-defined order in discotic liquid crystals, which can then be covalently captured by cross-linking and converted into a carbon material whose structure is an accurate replica of the molecular order in the precursor. This technique has been successfully applied to create innovative nanocarbons with controllable nanostructures. The new nanomaterials synthesized by supramolecular route include organic and carbon films with precise crystal structure control using surface anchoring and flow. Lithographic techniques were employed to make micro-patterned surfaces with preprogrammed molecular orientations. Fully dense and ordered carbon thin films were prepared from lytropic liquid crystals. These films exhibit surfaces rich in edge-sites and are either anisotropic unidirectional or multi-domain. In addition, four different types of high-aspect-ratio nanocarbons were synthesized and analyzed: (1) "orthogonal" carbon nanofibers with perpendicular graphene layers, (2) "concentric" C/C-composite nanofibers with graphene layers parallel to the fiber axis, (3) "inverted" nanotubes exhibiting graphene edge planes at both inner and outer surfaces, and (4) nanoribbons. Finally, a set of mesoporous carbons were synthesized with both porous structure and interfacial structure systematically controlled by liquid crystal templating. A quantitative model was developed for carbon surface area prediction. In addition to synthesis, this thesis includes extensive structural analysis and some surface characterization of these nanomaterials, and offers ideas to exploit their unique properties for applications in composites, displays, nanomedicine, and the environment.
Vabbilisetty, Pratima; Boron, Mallorie; Nie, Huan; Ozhegov, Evgeny; Sun, Xue-Long
2018-02-28
Introduction of selectively chemical reactive groups at the cell surface enables site-specific cell surface labeling and modification opportunity, thus facilitating the capability to study the cell surface molecular structure and function and the molecular mechanism it underlies. Further, it offers the opportunity to change or improve a cell's functionality for interest of choice. In this study, two chemical reactive anchor lipids, phosphatidylethanolamine-poly(ethylene glycol)-dibenzocyclooctyne (DSPE-PEG 2000 -DBCO) and cholesterol-PEG-dibenzocyclooctyne (CHOL-PEG 2000 -DBCO) were synthesized and their potential application for cell surface re-engineering via lipid fusion were assessed with RAW 264.7 cells as a model cell. Briefly, RAW 264.7 cells were incubated with anchor lipids under various concentrations and at different incubation times. The successful incorporation of the chemical reactive anchor lipids was confirmed by biotinylation via copper-free click chemistry, followed by streptavidin-fluorescein isothiocyanate binding. In comparison, the cholesterol-based anchor lipid afforded a higher cell membrane incorporation efficiency with less internalization than the phospholipid-based anchor lipid. Low cytotoxicity of both anchor lipids upon incorporation into the RAW 264.7 cells was observed. Further, the cell membrane residence time of the cholesterol-based anchor lipid was evaluated with confocal microscopy. This study suggests the potential cell surface re-engineering applications of the chemical reactive anchor lipids.
Lee, Shang-Hsuan; Sato, Yusuke; Hyodo, Mamoru; Harashima, Hideyoshi
2016-01-01
The surface topology of ligands on liposomes is an important factor in active targeting in drug delivery systems. Accurately evaluating the density of anchors and bioactive functional ligands on a liposomal surface is critical for ensuring the efficient delivery of liposomes. For evaluating surface ligand density, it is necessary to clarify that on the ligand-modified liposomal surfaces, some anchors are attached to ligands but some are not. To distinguish between these situations, a key parameter, surface anchor density, was introduced to specify amount of total anchors on the liposomal surface. Second, the parameter reaction yield was introduced to identify the amount of ligand-attached anchors among total anchors, since the conjugation efficiency is not always the same nor 100%. Combining these independent parameters, we derived: incorporation ratio=surface anchor density×reaction yield. The term incorporation ratio defines the surface ligand density. Since the surface anchor density represents the density of polyethylene glycol (PEG) on the surfaces in most cases, it also determines liposomal function. It is possible to accurately characterize various PEG and ligand densities and to define the surface topologies. In conclusion, this quantitative methodology can standardize the liposome preparation process and qualify the modified liposomal surfaces.
Intermittent use of an "anchor system" improves postural control in healthy older adults.
Freitas, Milena de Bem Zavanella; Mauerberg-deCastro, Eliane; Moraes, Renato
2013-07-01
Haptic information, provided by a non-rigid tool (i.e., an "anchor system"), can reduce body sway in individuals who perform a standing postural task. However, it was not known whether or not continuous use of the anchor system would improve postural control after its removal. Additionally, it was unclear as to whether or not frequency of use of the anchor system is related to improved control in older adults. The present study evaluated the effect of the prolonged use of the anchor system on postural control in healthy older individuals, at different frequencies of use, while they performed a postural control task (semi-tandem position). Participants were divided into three groups according to the frequency of the anchor system's use (0%, 50%, and 100%). Pre-practice phase (without anchor) was followed by a practice phase (they used the anchor system at the predefined frequency), and a post-practice phase (immediate and late-without anchor). All three groups showed a persistent effect 15min after the end of the practice phase (immediate post-practice phase). However, only the 50% group showed a persistent effect in the late post-practice phase (24h after finishing the practice phase). Older adults can improve their postural control by practicing the standing postural task, and use of the anchor system limited to half of their practice time can provide additional improvement in their postural control. Copyright © 2013 Elsevier B.V. All rights reserved.
The application of zero-profile anchored spacer in anterior cervical discectomy and fusion.
Wang, Zhiwen; Jiang, Weimin; Li, Xuefeng; Wang, Heng; Shi, Jinhui; Chen, Jie; Meng, Bin; Yang, Huilin
2015-01-01
We aimed to analyze the clinical efficacy of the zero-profile anchored spacers in the treatment of one-level or two-level cervical degenerative disc disease. From April 2011 to April 2013, a total of 63 consecutive patients with cervical degenerative disc disease who underwent one- or two-level ACDF using either the zero-profile anchored spacer or the stand-alone cages and a titanium plate fixation were reviewed for the radiological and clinical outcomes and complications. The zero-profile anchored spacers were used in 30 patients (anchored group) and stand-alone cages with an anterior cervical plate were implanted in 33 cases (non-anchored group). Operative time, intraoperative blood loss, clinical and radiological results were compared between the anchored group and the non-anchored group. All patients were followed up for at least 12 months. There were not bolt loosening or rupture of anchoring clips, screws or titanium plates observed in two groups during follow-up period. There were no significant difference in neck disability index scores, Japanese Orthopedic Association scores, fusion rate, and cervical lordosis during follow-up between two groups (P > 0.05), but significant difference in the operation time, blood loss and the presence of dysphagia were found (P < 0.05). There were no adjacent disc degeneration and instability observed in two groups. The zero-profile anchored spacer achieved similar clinical outcomes compared to ACDF with anterior plating for the treatment of the cervical degenerative disc disease. However, zero-profile anchored spacer was associated with a lower risk of postoperative dysphagia, shorter operation time, less blood loss, and relatively greater simplicity than the stand-alone cage with a titanium plate.
Orthodontic mechanics using mini-implant measured by FBG
NASA Astrophysics Data System (ADS)
Trannin, Pamela G.; Milczewski, Maura S.; de Oliveira, Walmir; Guariza Filho, Odilon; Lopes, Stephani C. P. S.; Kalinowski, Hypolito J.
2015-07-01
The magnitude of the force generated during orthodontic mechanics anchored in mini-implant in a maxilla model was analyzed. Data was collected during the insertion of the mini-implant and at the moment of applying forces to the structure of the maxilla and dentition. To obtain quantitative results, the Fibre Bragg Gratings (FBG) were inserted in an elastomeric material reproducing a maxilla model. It was observed levels of forces of approximately 3,78N next to the root of first premolar by the insertion of the mini-implant and different levels of the force to different orthodontic mechanics applied on the dental system.
ERIC Educational Resources Information Center
Marshall, Verena; Bonner, Dede
2003-01-01
The relationships among career anchors, age, culture, gender, employment experience, and the impact of career planning on downsizing were examined with data from 423 management students (49% had been downsized). Lifestyle was the most valued anchor across age groups, stability/security the least; compared with Schein's earlier anchors research,…
Effect of externally applied periodic force on ion acoustic waves in superthermal plasmas
NASA Astrophysics Data System (ADS)
Chowdhury, Snigdha; Mandi, Laxmikanta; Chatterjee, Prasanta
2018-04-01
Ion acoustic solitary waves in superthermal plasmas are investigated in the presence of trapped electrons. The reductive perturbation technique is employed to obtain a forced Korteweg-de Vries-like Schamel equation. An analytical solution is obtained in the presence of externally applied force. The effect of the external applied periodic force is also observed. The effect of the spectral index (κ), the strength ( f 0 ) , and the frequency ( ω ) on the amplitude and width of the solitary wave is obtained. The result may be useful in laboratory plasma as well as space environments.
Yan, H W; Li, L; Wang, R C; Yang, Y; Xie, Y; Tang, J; Shi, Z Y
2017-12-01
Comparison of clinical efficacies between coracoclavicular ligament reconstruction using autologous gracilis tendon with suture anchor and clavicular hook plate for the treatment of acute Neer type II distal clavicle fracture. Both coracoclavicular reconstruction with autologous gracilis tendon and clavicular hook plate could achieve satisfactory results for treating acute Neer type II distal clavicle fracture. Acute Neer type II distal clavicle fracture patients enrolled in this prospective randomized study were divided into the coracoclavicular ligament reconstruction group (using autologous gracilis tendon and suture anchor) and the hook plate group. Clinical outcomes were evaluated by shoulder X-ray, forward flexion, abduction and external rotation angle, Constant-Murley shoulder score and pain Visual Analogue Scale (VAS) at each follow-up for up to 24 months. The current study enrolled a total of 42 acute Neer type II distal clavicle fracture patients attended our hospital from March 2010 to December 2013. All patients had achieved complete healing and followed up for an average of 26 months (range, 24-38 months). At 3-month and 6-month follow-ups, Constant-Murley score in the ligament reconstruction group was significantly higher (93.8±2.6 vs. 88.7±8.7; 95.9±2.7 vs. 93.0±7.0, P<0.05), while VAS score was poorer than those in the hook plate group (1.6±0.8 vs. 2.5±1.9; 1.1±1.0 vs. 1.6±1.7, P<0.05). Reconstruction with autologous gracilis tendon improved VAS pain score in early postoperation follow-up; while Constant-Murley score and VAS score were significantly improved in the hook plate group after the implant was removed. These suggested that both coracoclavicular reconstruction with autologous gracilis tendon and clavicular hook plate could achieve satisfactory results. Level II, low-powered prospective randomized trial. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Congenital blindness limits allocentric to egocentric switching ability.
Ruggiero, Gennaro; Ruotolo, Francesco; Iachini, Tina
2018-03-01
Many everyday spatial activities require the cooperation or switching between egocentric (subject-to-object) and allocentric (object-to-object) spatial representations. The literature on blind people has reported that the lack of vision (congenital blindness) may limit the capacity to represent allocentric spatial information. However, research has mainly focused on the selective involvement of egocentric or allocentric representations, not the switching between them. Here we investigated the effect of visual deprivation on the ability to switch between spatial frames of reference. To this aim, congenitally blind (long-term visual deprivation), blindfolded sighted (temporary visual deprivation) and sighted (full visual availability) participants were compared on the Ego-Allo switching task. This task assessed the capacity to verbally judge the relative distances between memorized stimuli in switching (from egocentric-to-allocentric: Ego-Allo; from allocentric-to-egocentric: Allo-Ego) and non-switching (only-egocentric: Ego-Ego; only-allocentric: Allo-Allo) conditions. Results showed a difficulty in congenitally blind participants when switching from allocentric to egocentric representations, not when the first anchor point was egocentric. In line with previous results, a deficit in processing allocentric representations in non-switching conditions also emerged. These findings suggest that the allocentric deficit in congenital blindness may determine a difficulty in simultaneously maintaining and combining different spatial representations. This deficit alters the capacity to switch between reference frames specifically when the first anchor point is external and not body-centered.
Complete phase diagram of DNA unzipping: eye, Y fork, and triple point.
Kapri, Rajeev; Bhattacharjee, Somendra M; Seno, Flavio
2004-12-10
We study the unzipping of double stranded DNA by applying a pulling force at a fraction s (0< or =s < or =1) from the anchored end. From exact analytical and numerical results, the complete phase diagram is presented. The phase diagram shows a strong ensemble dependence for various values of s. In addition, we show the existence of an eye phase and a triple point.
Calculation and analysis on bolts on the slope of Xigeda soil
NASA Astrophysics Data System (ADS)
Wang, Wei; Chen, Wei; Long, Wei; Die, Jian
2018-03-01
In this paper, the commonly-used full-length bonded bolt in Xigeda soil and its slope support engineering is taken as the research object, applying the mechanical property indicator of Xigeda soil and two existing bolt load transmission mechanism and calculation theory, so that two calculation formulas of anchoring forces can be deduced, and verified by the experimental data. This paper has certain practical significance.
An Innovation Framework Applied to a Military Cyber Professionals Association
2013-09-01
of innovation generation described in the book , The Innovator’s Way, (IW) was selected as the framework for the skill sets required to establish the...fees nonexistent for service members. 38 Fritjof Capra, The Web of Life (New York: Anchor Books , 1996...distilled in the IW framework. The wisdom found in the pages of the IW book is a product of years of thoughtful contemplation of experiences and
Müller, Günter
2011-04-01
Glycosylphosphatidylinositol (GPI)-anchored proteins have been regarded as typical cell surface proteins found in most eukaryotic cells from yeast to man. They are embedded in the outer plasma membrane leaflet via a carboxy-terminally linked complex glycolipid GPI structure. The amphiphilic nature of the GPI anchor, its compatibility with the function of the attached protein moiety and the capability of GPI-anchored proteins for spontaneous insertion into and transfer between artificial and cellular membranes initially suggested their potential for biotechnological applications. However, these expectations have been hardly fulfilled so far. Recent developments fuel novel hopes with regard to: (i) Automated online expression, extraction and purification of therapeutic proteins as GPI-anchored proteins based on their preferred accumulation in plasma membrane lipid rafts, (ii) multiplex custom-made protein chips based on GPI-anchored cell wall proteins in yeast, (iii) biomaterials and biosensors with films consisting of sets of distinct GPI-anchored binding-proteins or enzymes for sequential or combinatorial catalysis, and (iv) transport of therapeutic proteins across or into relevant tissue cells, e.g., enterocytes or adipocytes. Latter expectations are based on the demonstrated translocation of GPI-anchored proteins from plasma membrane lipid rafts to cytoplasmic lipid droplets and eventually further into microvesicles which upon release from donor cells transfer their GPI-anchored proteins to acceptor cells. The value of these technologies, which are all based on the interaction of GPI-anchored proteins with membranes and surfaces, for the engineering, production and targeted delivery of biomolecules for a huge variety of therapeutic and biotechnological purposes should become apparent in the near future.
2018-01-01
Introduction of selectively chemical reactive groups at the cell surface enables site-specific cell surface labeling and modification opportunity, thus facilitating the capability to study the cell surface molecular structure and function and the molecular mechanism it underlies. Further, it offers the opportunity to change or improve a cell’s functionality for interest of choice. In this study, two chemical reactive anchor lipids, phosphatidylethanolamine–poly(ethylene glycol)–dibenzocyclooctyne (DSPE–PEG2000–DBCO) and cholesterol–PEG–dibenzocyclooctyne (CHOL–PEG2000–DBCO) were synthesized and their potential application for cell surface re-engineering via lipid fusion were assessed with RAW 264.7 cells as a model cell. Briefly, RAW 264.7 cells were incubated with anchor lipids under various concentrations and at different incubation times. The successful incorporation of the chemical reactive anchor lipids was confirmed by biotinylation via copper-free click chemistry, followed by streptavidin-fluorescein isothiocyanate binding. In comparison, the cholesterol-based anchor lipid afforded a higher cell membrane incorporation efficiency with less internalization than the phospholipid-based anchor lipid. Low cytotoxicity of both anchor lipids upon incorporation into the RAW 264.7 cells was observed. Further, the cell membrane residence time of the cholesterol-based anchor lipid was evaluated with confocal microscopy. This study suggests the potential cell surface re-engineering applications of the chemical reactive anchor lipids. PMID:29503972
Parametric Study on Responses of a Self-Anchored Suspension Bridge to Sudden Breakage of a Hanger
Jiang, Meng; Huang, Cailiang
2014-01-01
The girder of self-anchored suspension bridge is subjected to large compression force applied by main cables. So, serious damage of the girder due to breakage of hangers may cause the collapse of the whole bridge. With the time increasing, the hangers may break suddenly for their resistance capacities decrease due to corrosion. Using nonlinear static and dynamic analysis methods and adopting 3D finite element model, the responses of an actual self-anchored suspension bridge to sudden breakage of hangers are studied in this paper. The results show that the sudden breakage of a hanger causes violent vibration and large changes in internal forces of the bridge. In the process of the vibration, the maximum tension of hanger produced by breakage of a hanger exceeds 2.22 times its initial value, and the reaction forces of the bearings increase by more than 1.86 times the tension of the broken hanger. Based on the actual bridge, the influences of some factors including flexural stiffness of girder, torsion stiffness of girder, flexural stiffness of main cable, weight of girder, weight of main cable, span to sag ratio of main cable, distance of hangers, span length, and breakage time of hanger on the dynamic responses are studied in detail, and the influencing extent of the factors is presented. PMID:25045734
Parametric study on responses of a self-anchored suspension bridge to sudden breakage of a hanger.
Qiu, Wenliang; Jiang, Meng; Huang, Cailiang
2014-01-01
The girder of self-anchored suspension bridge is subjected to large compression force applied by main cables. So, serious damage of the girder due to breakage of hangers may cause the collapse of the whole bridge. With the time increasing, the hangers may break suddenly for their resistance capacities decrease due to corrosion. Using nonlinear static and dynamic analysis methods and adopting 3D finite element model, the responses of an actual self-anchored suspension bridge to sudden breakage of hangers are studied in this paper. The results show that the sudden breakage of a hanger causes violent vibration and large changes in internal forces of the bridge. In the process of the vibration, the maximum tension of hanger produced by breakage of a hanger exceeds 2.22 times its initial value, and the reaction forces of the bearings increase by more than 1.86 times the tension of the broken hanger. Based on the actual bridge, the influences of some factors including flexural stiffness of girder, torsion stiffness of girder, flexural stiffness of main cable, weight of girder, weight of main cable, span to sag ratio of main cable, distance of hangers, span length, and breakage time of hanger on the dynamic responses are studied in detail, and the influencing extent of the factors is presented.
Croxford, Adam E; Rogers, Tom; Caligari, Peter D S; Wilkinson, Michael J
2008-01-01
* The provision of sequence-tagged site (STS) anchor points allows meaningful comparisons between mapping studies but can be a time-consuming process for nonmodel species or orphan crops. * Here, the first use of high-resolution melt analysis (HRM) to generate STS markers for use in linkage mapping is described. This strategy is rapid and low-cost, and circumvents the need for labelled primers or amplicon fractionation. * Using white lupin (Lupinus albus, x = 25) as a case study, HRM analysis was applied to identify 91 polymorphic markers from expressed sequence tag (EST)-derived and genomic libraries. Of these, 77 generated STS anchor points in the first fully resolved linkage map of the species. The map also included 230 amplified fragment length polymorphisms (AFLP) loci, spanned 1916 cM (84.2% coverage) and divided into the expected 25 linkage groups. * Quantitative trait loci (QTL) analyses performed on the population revealed genomic regions associated with several traits, including the agronomically important time to flowering (tf), alkaloid synthesis and stem height (Ph). Use of HRM-STS markers also allowed us to make direct comparisons between our map and that of the related crop, Lupinus angustifolius, based on the conversion of RFLP, microsatellite and single nucleotide polymorphism (SNP) markers into HRM markers.
33 CFR 150.905 - Why are safety zones, no anchoring areas, and areas to be avoided established?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Why are safety zones, no...: OPERATIONS Safety Zones, No Anchoring Areas, and Areas To Be Avoided § 150.905 Why are safety zones, no anchoring areas, and areas to be avoided established? (a) Safety zones, no anchoring areas (NAAs) and areas...
ERIC Educational Resources Information Center
Wang, Wen-Chung
2004-01-01
Scale indeterminacy in analysis of differential item functioning (DIF) within the framework of item response theory can be resolved by imposing 3 anchor item methods: the equal-mean-difficulty method, the all-other anchor item method, and the constant anchor item method. In this article, applicability and limitations of these 3 methods are…
Engineered photosynthetic bacteria, method of manufacture of biofuels
Laible, Philip D.; Snyder, Seth W.
2016-09-13
The invention provides for a novel type of biofuel; a method for cleaving anchors from photosynthetic organisms; and a method for producing biofuels using photosynthetic organisms, the method comprising identifying photosynthesis co-factors and their anchors in the organisms; modifying the organisms to increase production of the anchors; accumulating biomass of the organisms in growth media; and harvesting the anchors.
Plant glycosylphosphatidylinositol (GPI) anchored proteins at the plasma membrane-cell wall nexus.
Yeats, Trevor H; Bacic, Antony; Johnson, Kim L
2018-04-18
Approximately 1% of plant proteins are predicted to be post-translationally modified with a glycosylphosphatidylinositol (GPI) anchor that tethers the polypeptide to the outer leaflet of the plasma membrane. While the synthesis and structure of GPI anchors is largely conserved across eukaryotes, the repertoire of functional domains present in the GPI-anchored proteome has diverged substantially. In plants, this includes a large fraction of the GPI-anchored proteome being further modified with plant-specific arabinogalactan (AG) O-glycans. The importance of the GPI-anchored proteome to plant development is underscored by the fact that GPI biosynthetic null mutants exhibit embryo lethality. Mutations in genes encoding specific GPI-anchored proteins (GAPs) further supports their contribution to diverse biological processes occurring at the interface of the plasma membrane and cell wall, including signaling, cell wall metabolism, cell wall polymer cross-linking, and plasmodesmatal transport. Here, we review the literature concerning plant GPI-anchored proteins in the context of their potential to act as molecular hubs that mediate interactions between the plasma membrane and the cell wall and their potential to transduce the signal into the protoplast and thereby activate signal transduction pathways. This article is protected by copyright. All rights reserved.
Suzuki, Yasutomo; Saito, Yuka; Ogushi, Satoko; Kimura, Go; Kondo, Yukihiro
2012-10-01
Herein we describe our experience with a bone-anchored sling using a suture anchor and polypropylene mesh for the treatment of post-radical prostatectomy urinary incontinence. Eight patients with urinary incontinence as a result of intrinsic sphincter deficiency after radical prostatectomy were included in the analysis. The procedure involved piercing the pubic bone with a bone drill, inserting the suture anchor and fixing a soft or rigid polypropylene mesh to press firmly on the bulbar urethra. Urinary incontinence was significantly improved according to changes in the daily number of pads used at 1, 3 and 6 months postoperatively in comparison with preoperatively. However, no meaningful improvement at 6 months postoperatively was seen with the soft mesh. Complications included perineal pain in four cases, but pain control was achieved using non-steroidal anti-inflammatory drugs. The bone-anchored sling with a suture anchor and polypropylene mesh appears to be safe and effective for the treatment of post-radical prostatectomy urinary incontinence. Soft mesh appears inappropriate as material for the bone-anchored sling because of the progressive likelihood of worsened urinary incontinence. © 2012 The Japanese Urological Association.
Hu, Jinglei; Lipowsky, Reinhard; Weikl, Thomas R
2013-09-17
Cell adhesion and the adhesion of vesicles to the membranes of cells or organelles are pivotal for immune responses, tissue formation, and cell signaling. The adhesion processes depend sensitively on the binding constant of the membrane-anchored receptor and ligand proteins that mediate adhesion, but this constant is difficult to measure in experiments. We have investigated the binding of membrane-anchored receptor and ligand proteins with molecular dynamics simulations. We find that the binding constant of the anchored proteins strongly decreases with the membrane roughness caused by thermally excited membrane shape fluctuations on nanoscales. We present a theory that explains the roughness dependence of the binding constant for the anchored proteins from membrane confinement and that relates this constant to the binding constant of soluble proteins without membrane anchors. Because the binding constant of soluble proteins is readily accessible in experiments, our results provide a useful route to compute the binding constant of membrane-anchored receptor and ligand proteins.
Improving performance by anchoring movement and "nerves".
Iso-Ahola, Seppo E; Dotson, Charles O; Jagodinsky, Adam E; Clark, Lily C; Smallwood, Lorraine L; Wilburn, Christopher; Weimar, Wendi H; Miller, Matthew W
2016-10-01
Golf's governing bodies' recent decision to ban all putting styles "anchoring one end of the club against the body" bridges an important practical problem with psychological theory. We report the first experiment testing whether anchoring provides technical and/or psychological advantage in competitive performance. Many "greats" of professional golf from Arnold Palmer and Jack Nicklaus to Tiger Woods have argued against anchoring, believing that it takes "nerves" out of competitive performance and therefore artificially levels the playing field. To shed more light on the issue, we tested participants' performance with anchored and unanchored putters under low and high pressure when controlling for the putter length. We found no statistically significant evidence for a technical advantage due to anchoring but a clear psychological advantage: participants who anchored their putters significantly outperformed unanchored counterparts under high, but not low, pressure. Results provide tentative evidence for the ban's justification from a competitive standpoint. However, before any definite conclusions can be made, more research is needed when using high-level golfers. Copyright © 2016 Elsevier B.V. All rights reserved.
Pattern-induced anchoring transitions in nematic liquid crystals
NASA Astrophysics Data System (ADS)
Rojas-Gómez, Óscar A.; Romero-Enrique, José M.; Silvestre, Nuno M.; Telo da Gama, Margarida M.
2017-02-01
In this paper we revisit the problem of a nematic liquid crystal in contact with patterned substrates. The substrate is modelled as a periodic array of parallel infinite grooves of well-defined cross-section sculpted on a chemically homogeneous substrate which favours local homeotropic anchoring of the nematic. We consider three cases: a sawtooth, a crenellated and a sinusoidal substrate. We analyse this problem within the modified Frank-Oseen formalism. We argue that, for substrate periodicities much larger than the extrapolation length, the existence of different nematic textures with distinct far-field orientations, as well as the anchoring transitions between them, are associated with the presence of topological defects either on or close to the substrate. For the sawtooth and sinusoidal cases, we observe a homeotropic to planar anchoring transition as the substrate roughness increases. On the other hand, a homeotropic to oblique anchoring transition is observed for crenellated substrates. In this case, the anchoring phase diagram shows a complex dependence on the substrate roughness and substrate anchoring strength.
Zúñiga-Navarrete, Fernando; Gómez, Isabel; Peña, Guadalupe; Bravo, Alejandra; Soberón, Mario
2013-03-01
Bacillus thuringiensis Cry toxins recognizes their target cells in part by the binding to glycosyl-phosphatidyl-inositol (GPI) anchored proteins such as aminopeptidase-N (APN) or alkaline phosphatases (ALP). Treatment of Tenebrio molitor brush border membrane vesicles (BBMV) with phospholipase C that cleaves out GPI-anchored proteins from the membranes, showed that GPI-anchored proteins are involved in binding of Cry3Aa toxin to BBMV. A 68 kDa GPI-anchored ALP was shown to bind Cry3Aa by toxin overlay assays. The 68 kDa GPI-anchored ALP was preferentially expressed in early instar larvae in comparison to late instar larvae. Our work shows for the first time that GPI-anchored ALP is important for Cry3Aa binding to T. molitor BBMV suggesting that the mode of action of Cry toxins is conserved in different insect orders. Copyright © 2012 Elsevier Inc. All rights reserved.
Metz, C N; Thomas, P; Davitz, M A
1992-06-01
A large number of eukaryotic proteins have been shown to be anchored to the cell membrane by glycosylphosphatidylinositol (GPI). This glycolipid anchor can serve as a substrate for anchor-specific phospholipases that convert the GPI-anchored membrane proteins into soluble forms. Soluble forms of many GPI anchored proteins have been identified in vivo in connective tissue, plasma, and urine. The authors have discovered that mammalian plasma contains a GPI-specific phospholipase D (GPI-PLD). Because it recognizes a portion of the conserved glycan core structure, all GPI-anchored proteins are potential substrates. The authors report the development of a murine monoclonal antibody specific for one form of the human GPI-PLD and the immunohistochemical localization of this enzyme to mast cells.
Goudeketting, Seline R; van Noort, Kim; Ouriel, Kenneth; Jordan, William D; Panneton, Jean M; Slump, Cornelis H; de Vries, Jean-Paul P M
2018-04-21
This study sought to quantify EndoAnchor (Medtronic Vascular, Santa Rosa, Calif) penetration into the aortic wall in patients undergoing endovascular abdominal aortic aneurysm repair and to assess predictors of successful penetration and its relationship to postprocedural type IA endoleak. A subset of patients from the Aneurysm Treatment Using the Heli-FX Aortic Securement System Global Registry (ANCHOR) were included if they met the following criteria: the indication for EndoAnchor use was to treat a type IA endoleak, and postprocedure contrast-enhanced computed tomography (CT) scans of sufficient quality were available for core laboratory review. Patients undergoing implantation of cuffs or stents during the EndoAnchor implantation procedure were excluded. Baseline anatomic characteristics were recorded. The cohort was divided into patients with and without persistent type IA endoleaks at the first postoperative CT scan. Penetration of each EndoAnchor measured on this CT scan was defined as good penetration when the EndoAnchor penetrated ≥2 mm into the aortic wall, borderline penetration when EndoAnchor penetration was <2 mm or a gap remained between the endograft and aortic wall, or no penetration when the EndoAnchor did not penetrate into the aortic wall. Differences between the groups were analyzed with the Mann-Whitney U test or Fisher exact test. Multivariate analyses were performed to identify independent predictors of EndoAnchor penetration, and procedural success was defined by absence of type IA endoleak. Eighty-six patients of the primary (n = 61 [71%]) and revision (n = 25 [29%]) arms of the ANCHOR registry were included. There were 53 (62%) without and 33 (38%) with persistent type IA endoleaks on the first postprocedural CT scan. The median number of EndoAnchors with good penetration was significantly greater in the cohort without endoleaks, 4 (interquartile range, 3-5) vs 3 (interquartile range, 1.5-4), respectively (P = .002). A multivariate model for EndoAnchor penetration identified use of a Medtronic Endurant endograft as a factor associated with good penetration (P = .001), whereas poor penetration was associated with a larger aortic neck diameter 10 mm distal to the lowest renal artery (P < .001) and greater proximal neck calcium thickness (P = .004). EndoAnchor penetration was the only variable that attained significance (P < .001) in the multivariate model for successful treatment of a type IA endoleak. Adequate EndoAnchor penetration into the aortic wall is less likely when the aortic neck diameter is large or when the neck contains significant mural calcium. No penetration of the EndoAnchor was the only factor predictive of postprocedural type IA endoleak. This study stresses the importance of careful selection of patients based on preoperative assessment of the infrarenal neck on CT angiography and emphasizes careful deployment of EndoAnchors into the aortic wall to improve successful treatment of type IA endoleaks. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Sequestration of GPI-anchored proteins in caveolae triggered by cross-linking.
Mayor, S; Rothberg, K G; Maxfield, F R
1994-06-24
Glycosyl-phosphatidylinositol (GPI)-anchored proteins have been reported to reside in clusters collected over small membrane invaginations called caveolae. The detection of different GPI-anchored proteins with fluorescently labeled monoclonal antibodies showed that these proteins are not constitutively concentrated in caveolae; they enter these structures independently after cross-linking with polyclonal secondary antibodies. Analysis of the cell surface distribution of the GPI-anchored folate receptor by electron microscopy confirms these observations. Thus, multimerization of GPI-anchored proteins regulates their sequestration in caveolae, but in the absence of agents that promote clustering they are diffusely distributed over the plasma membrane.
Eun, Sang Soo; Lee, Sang Ho; Sabal, Luigi Andrew
2016-08-01
There are numerous methods for repairing posterior root tears of the medial meniscus (PRTMM). Repair techniques using suture anchors through a high posteromedial portal have been reported. The present study found that using a knotless suture anchor instead of suture anchor seemed easier and faster because it avoided passing the sutures through the meniscus and tying a knot in a small space. This study describes a knotless suture anchor technique through a high posteromedial portal, and its clinical results. Copyright © 2016 Elsevier B.V. All rights reserved.
49 CFR 195.588 - What standards apply to direct assessment?
Code of Federal Regulations, 2011 CFR
2011-10-01
... TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Corrosion Control § 195.588 What standards apply to direct... corrosion, you must follow the requirements of this section for performing external corrosion direct... direct assessment process. (b) The requirements for performing external corrosion direct assessment are...
49 CFR 195.588 - What standards apply to direct assessment?
Code of Federal Regulations, 2014 CFR
2014-10-01
... TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Corrosion Control § 195.588 What standards apply to direct... corrosion, you must follow the requirements of this section for performing external corrosion direct... direct assessment process. (b) The requirements for performing external corrosion direct assessment are...
49 CFR 195.588 - What standards apply to direct assessment?
Code of Federal Regulations, 2012 CFR
2012-10-01
... TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Corrosion Control § 195.588 What standards apply to direct... corrosion, you must follow the requirements of this section for performing external corrosion direct... direct assessment process. (b) The requirements for performing external corrosion direct assessment are...
49 CFR 195.588 - What standards apply to direct assessment?
Code of Federal Regulations, 2013 CFR
2013-10-01
... TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Corrosion Control § 195.588 What standards apply to direct... corrosion, you must follow the requirements of this section for performing external corrosion direct... direct assessment process. (b) The requirements for performing external corrosion direct assessment are...
Nonlinear modeling of forced magnetic reconnection in slab geometry with NIMROD
NASA Astrophysics Data System (ADS)
Beidler, M. T.; Callen, J. D.; Hegna, C. C.; Sovinec, C. R.
2017-05-01
The nonlinear, extended-magnetohydrodynamic (MHD) code NIMROD is benchmarked with the theory of time-dependent forced magnetic reconnection induced by small resonant fields in slab geometry in the context of visco-resistive MHD modeling. Linear computations agree with time-asymptotic, linear theory of flow screening of externally applied fields. The inclusion of flow in nonlinear computations can result in mode penetration due to the balance between electromagnetic and viscous forces in the time-asymptotic state, which produces bifurcations from a high-slip state to a low-slip state as the external field is slowly increased. We reproduce mode penetration and unlocking transitions by employing time-dependent externally applied magnetic fields. Mode penetration and unlocking exhibit hysteresis and occur at different magnitudes of applied field. We also establish how nonlinearly determined flow screening of the resonant field is affected by the square of the magnitude of the externally applied field. These results emphasize that the inclusion of nonlinear physics is essential for accurate prediction of the reconnected field in a flowing plasma.
ERIC Educational Resources Information Center
Moses, Tim; Deng, Weiling; Zhang, Yu-Li
2010-01-01
In the equating literature, a recurring concern is that equating functions that utilize a single anchor to account for examinee groups' nonequivalence are biased when the groups are extremely different and/or when the anchor only weakly measures what the tests measure. Several proposals have been made to address this equating bias by incorporating…
The Place of White in a World of Grays: A Double-Anchoring Theory of Lightness Perception
ERIC Educational Resources Information Center
Bressan, Paola
2006-01-01
The specific gray shades in a visual scene can be derived from relative luminance values only when an anchoring rule is followed. The double-anchoring theory I propose in this article, as a development of the anchoring theory of Gilchrist et al. (1999), assumes that any given region (a) belongs to one or more frameworks, created by Gestalt…
ERIC Educational Resources Information Center
Wiberg, Marie; von Davier, Alina A.
2017-01-01
We propose a comprehensive procedure for the implementation of a quality control process of anchor tests for a college admissions test with multiple consecutive administrations. We propose to examine the anchor tests and their items in connection with covariates to investigate if there was any unusual behavior in the anchor test results over time…
An anchoring system for fish habitat structures: field technique, evaluation, and application.
Barbara L. Fontaine; Thomas D. Merritt
1988-01-01
Steel cable can be used to bind rocks and logs together to construct fish habitat structures in streams. Cables must be securely anchored if structures are to withstand floods. This paper describes a way to anchor cables into bedrock or ballast boulders. Anchor tensile strength ranged from 7,500 to 36,500 pounds and was related to type of resin and embedment depth....
Archaeometallurgical investigation of the iron anchor from the Tantura F shipwreck
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aronson, A.; Ashkenazi, D., E-mail: dana@eng.tau.ac.il; Barkai, O.
2013-04-15
The Tantura F shipwreck was a coaster or a fishing vessel about 15.7 m long, discovered in the Dor/Tantura lagoon, Israel in 1995. It was dated to between the mid-7th and the end of the 8th centuries CE. Among the finds excavated were two T-shaped type iron anchors. Of the two anchors, one (anchor A) was thoroughly studied by archaeometallurgical methods in order to identify forge-welding lines, to determine the welding quality and to understand the manufacturing technology. The examinations included X-ray radiography, XRF analysis, optical microscopy, SEM/EDS observation and analysis, OES analysis and microhardness tests. The investigation included characterizationmore » of the composition, microstructure, thermal treatments, forge-welding junctions and slag analysis. The results revealed a heterogeneous microstructure, rich in glassy, fayalite and wüstite slag. Iron based phases included ferrite, pearlite, cementite and Widmanstätten plates, all typical to wrought iron. The forge-welds of Anchor A were located. Each arm was made of one piece, weighing about 2.5–3 kg and the shank was made of a few 1.5–2 kg pieces. The second anchor (anchor B) was only briefly examined visually and with a few radiographs, which support the results from anchor A. The research results revealed significant information about T-shaped anchors and their manufacturing process, including hot-working processes without any additional heat treatments, and folding techniques. The microstructure was similar to other ancient simple tools such as saws, sickles, axes and mortise chisels, and though the technology to make complicated structures and objects, such as swords, existed at that time, the anchors did not require this sophistication; thus simpler techniques were used, presumably because they were more cost-effective. - Highlights: ► Tantura F was a coaster dated to mid-7th–end-8th centuries. ► Two iron anchors were discovered at the Tantura F shipwreck-site. ► Anchor A was manufactured from heterogeneous wrought iron blooms. ► Forge-welding lines were detected using archaeometallurgical methods.« less
NASA Astrophysics Data System (ADS)
Jasiczak, Józef; Girus, Krzysztof
2017-10-01
The issue of usability and durability of large-panel building constructed several decades ago is a subject of an in-depth analysis of many domestic and foreign investments. When considering the durability of specific large-panel system, one should consider, among others, the process of making external walls. The long-term and direct impact of weather conditions on the external layer of curtain walls is significant for the durability of large-panel buildings. For the needs of the presented paper, in 2016, the survey of cracks and a series of other tests of large-panel façade, residential building constructed in 1986, in Poland, in the PLP process system - Rataje was executed. Several hundred large-size, triple-layer curtain-wall slab with a 6-cm, concrete exterior cladding layer anchored using pins and hangers with the load-bearing layer, a 9-cm insulation layer made of mineral wool, and a 21-cm structural layer were surveyed. Significant deviations in thicknesses of particular wall layers were proven. Other significant damages and defects of external layers were found. At the second stage, many tests, both nondestructive and destructive, were conducted. They involved determining mechanical properties of an external layer. The concrete thickness was measured using with a type N Schmidt sclerometer and core samples were taken from this layer in order to mark concrete’s compressive strength. The range of carbonation (by phenolphthalein method) and the actual location and condition of reinforcement were estimated using a ferromagnetic device to determine the condition of the external layer. The diagnosis conducted in such a manner was the verification of necessary repair of the walls and their thermal efficiency improvement while ensuring safe conditions of their operation and modern functional and utility requirements. It should be also emphasized that the method of diagnosing the external walls presented in this paper may be popularized when evaluating such facilities both in Poland and other countries of the Central Europe (Germany, Czechia, Slovakia, Lithuania, Bulgaria, and Ukraine).
Fukushima, Keiko; Ikehara, Yukio; Kanai, Michiko; Kochibe, Naohisa; Kuroki, Masahide; Yamashita, Katsuko
2003-09-19
Glycosylphosphatidylinositol (GPI)-anchored proteins are ubiquitous in eukaryotes. The minimum conserved GPI core structure of all GPI-anchored glycans has been determined as EtN-PO4-6Manalpha1-2Manalpha1-6Manalpha1-4GlcN-myo-inositol-PO3H. Human placental alkaline phosphatase (AP) has been reported to be a GPI-anchored membrane protein. AP carries one N-glycan, (NeuAcalpha2-->3)2Gal2GlcNAc2Man3GlcNAc(+/-Fuc)GlcNAc, and a GPI anchor, which contains an ethanolamine phosphate diester group, as a side chain. However, we found that both sialidase-treated soluble AP (sAP) and its GPI-anchored glycan bound to a Psathyrella velutina lectin (PVL)-Sepharose column, which binds beta-GlcNAc residues. PVL binding of asialo-sAP and its GPI-anchored glycan was diminished by digestion with diplococcal beta-N-acetylhexosaminidase or by mild acid treatment. After sequential digestion of asialo-sAP with beta-N-acetylhexosaminidase and acid phosphatase, the elution patterns on chromatofocusing gels were changed in accordance with the negative charges of phosphate residues. Trypsin-digested sAP was analyzed by liquid chromatography/electrospray ionization mass spectrometry, and the structures of two glycopeptides with GPI-anchored glycans were confirmed as peptide-EtN-PO4-6Manalpha1-->2(GlcNAcbeta1-PO4-->6)Manalpha1-6(+/-EtN-PO4-->)Manalpha1-->4GlcN, which may be produced by endo-alpha-glucosaminidase. In addition to AP, GPI-anchored carcinoembryonic antigen, cholinesterase, and Tamm-Horsfall glycoprotein also bound to a PVL-Sepharose column, suggesting that the beta-N-acetylglucosaminyl phosphate diester residue is widely distributed in human GPI-anchored glycans. Furthermore, we found that the beta-N-acetylglucosaminyl phosphate diester residue is important for GPI anchor recognition of aerolysin, a channel-forming toxin derived from Aeromonas hydrophila.
Noyes, Matthew P; Lederman, Evan; Adams, Christopher R; Denard, Patrick J
2018-05-01
To compare the biomechanical properties of single-row repair with triple-loaded (TL) anchor repair versus a knotless rip stop (KRS) repair in a rotator cuff repair model. Rotator cuff tears were created in 8 cadaveric matched-pair specimens and repaired with a TL anchor or KRS construct. In the TL construct, anchors were placed in the greater tuberosity and then all suture limbs were passed through the rotator cuff as simple sutures and tied. In the KRS construct, a 2-mm suture tape was passed through the tendon in an inverted mattress fashion, and a free suture was passed medial to the suture tape to create a rip-stop. Then, the suture tape and free suture were secured with knotless anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 438 ± 59 N in TL anchor repairs compared with 457 ± 110 N in KRS repairs (P = .582). The mean displacement with cyclic loading was 3.8 ± 1.6 mm in TL anchor repairs versus 4.3 ± 1.8 mm in the KRS group (P = .297). Mode of failure was consistent in both groups, with 6 of 8 failures in the TL anchor group and 7 of 8 failures in KRS group occurring from anchor pullout. There is no statistical difference in load to failure and cyclic loading between TL anchor and KRS single-row repair techniques. KRS repair technique may be an alternative method of repairing full-thickness supraspinatus tendon tears with a single-row construct. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Strain engineering of graphene nanoribbons: pseudomagnetic versus external magnetic fields
NASA Astrophysics Data System (ADS)
Prabhakar, Sanjay; Melnik, Roderick; Bonilla, Luis
2017-05-01
Bandgap opening due to strain engineering is a key architect for making graphene's optoelectronic, straintronic, and spintronic devices. We study the bandgap opening due to strain induced ripple waves and investigate the interplay between pseudomagnetic fields and externally applied magnetic fields on the band structures and spin relaxation in graphene nanoribbons (GNRs). We show that electron-hole bands of GNRs are highly influenced (i.e. level crossing of the bands are possible) by coupling two combined effects: pseudomagnetic fields (PMF) originating from strain tensor and external magnetic fields. In particular, we show that the tuning of the spin-splitting band extends to large externally applied magnetic fields with increasing values of pseudomagnetic fields. Level crossings of the bands in strained GNRs can also be observed due to the interplay between pseudomagnetic fields and externally applied magnetic fields. We also investigate the influence of this interplay on the electromagnetic field mediated spin relaxation mechanism in GNRs. In particular, we show that the spin hot spot can be observed at approximately B = 65 T (the externally applied magnetic field) and B0 = 53 T (the magnitude of induced pseudomagnetic field due to ripple waves) which may not be considered as an ideal location for the design of straintronic devices. Our analysis might be used for tuning the bandgaps in strained GNRs and utilized to design the optoelectronic devices for straintronic applications.
Synergistic anti-tumor effect of glycosylphosphatidylinositol-anchored IL-2 and IL-12.
Ji, Jianfei; Li, Jinhua; Holmes, Lillia M; Burgin, Kelly E; Yu, Xianzhong; Wagner, Thomas E; Wei, Yanzhang
2004-07-01
Preclinical and clinical studies have demonstrated that interleukin 2 (IL-2), interleukin 12 (IL-12), and some other cytokines, play important roles in activating host immune responses against tumor growth. However, severe side effects caused by systemic high-dose administration of these cytokines limit their clinical application. In our previous study, local high doses of IL-2 were achieved by a GPI-anchoring technology; therefore, it will be interesting to know if this technology works for other cytokines. A fusion gene containing murine IL-12 and the glycosylphosphatidylinositol (GPI) anchor signal sequence was generated and transfected into the murine melanoma tumor cell line B16F0 either alone or together with a vector encoding GPI-anchored IL-2. The GPI-anchored cytokine expression of the selected stable clones was assayed in vitro by ELISA and their anti-tumor effects were analyzed in vivo by tumor lymphocyte infiltration and tumor growth studies. GPI-anchored IL-12 was successfully expressed on the cell surface as indicated by FACS analysis and IL-12 ELISA assay. The GPI-anchored IL-12 enhanced lymphocyte infiltration and significantly inhibited tumor growth. More importantly, when GPI-anchored IL-12 and GPI-anchored IL-2 were co-delivered, a synergistic anti-tumor effect was observed in both subcutaneous and intravenous tumor models. GPI anchorage of cytokines represents a new approach to locally deliver high doses of cytokines without the severe adverse effects normally accompanied with systematic high-dose administration of these cytokines. Copyright 2004 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
English, Niall J.; Garate, José-A.
2016-08-01
An extensive suite of non-equilibrium molecular-dynamics simulation has been performed for ˜0.85-0.9 μs of human aquaporin 4 in the absence and presence of externally applied static and alternating electric fields applied along the channels (in both axial directions in the static case, taken as the laboratory z-axis). These external fields were of 0.0065 V/Å (r.m.s.) intensity (of the same order as physiological electrical potentials); alternating fields ranged in frequency from 2.45 to 500 GHz. In-pore gating dynamics was studied, particularly of the relative propensities for "open" and "closed" states of the conserved arginines in the arginine/aromatic area (itself governed in no small part by external-field response of the dipolar alignment of the histidine-201 residue in the selectivity filter). In such a manner, the intimate connection of field-response governing "two-state" histidine states was established statistically and mechanistically. Given the appreciable size of the energy barriers for histidine-201 alignment, we have also performed non-equilibrium metadynamics/local-elevation of static fields applied along both directions to construct the free-energy landscape thereof in terms of external-field direction, elucidating the importance of field direction on energetics. We conclude from direct measurement of deterministic molecular dynamics in conjunction with applied-field metadynamics that the intrinsic electric field within the channel points along the +z-axis, such that externally applied static fields in this direction serve to "open" the channel in the selectivity-filter and the asparagine-proline-alanine region.
English, Niall J; Garate, José-A
2016-08-28
An extensive suite of non-equilibrium molecular-dynamics simulation has been performed for ∼0.85-0.9 μs of human aquaporin 4 in the absence and presence of externally applied static and alternating electric fields applied along the channels (in both axial directions in the static case, taken as the laboratory z-axis). These external fields were of 0.0065 V/Å (r.m.s.) intensity (of the same order as physiological electrical potentials); alternating fields ranged in frequency from 2.45 to 500 GHz. In-pore gating dynamics was studied, particularly of the relative propensities for "open" and "closed" states of the conserved arginines in the arginine/aromatic area (itself governed in no small part by external-field response of the dipolar alignment of the histidine-201 residue in the selectivity filter). In such a manner, the intimate connection of field-response governing "two-state" histidine states was established statistically and mechanistically. Given the appreciable size of the energy barriers for histidine-201 alignment, we have also performed non-equilibrium metadynamics/local-elevation of static fields applied along both directions to construct the free-energy landscape thereof in terms of external-field direction, elucidating the importance of field direction on energetics. We conclude from direct measurement of deterministic molecular dynamics in conjunction with applied-field metadynamics that the intrinsic electric field within the channel points along the +z-axis, such that externally applied static fields in this direction serve to "open" the channel in the selectivity-filter and the asparagine-proline-alanine region.
Code of Federal Regulations, 2010 CFR
2010-04-01
... PROVISIONALLY LISTED COLORS AND SPECIFICATIONS Externally Applied Drugs and Cosmetics § 82.2050 General. A batch of a straight color listed in this subpart may be certified, in accordance with the provisions of this part, for use in externally applied drugs and cosmetics, if such batch conforms to the...
ERIC Educational Resources Information Center
Lin, Peng; Dorans, Neil; Weeks, Jonathan
2016-01-01
The nonequivalent groups with anchor test (NEAT) design is frequently used in test score equating or linking. One important assumption of the NEAT design is that the anchor test is a miniversion of the 2 tests to be equated/linked. When the content of the 2 tests is different, it is not possible for the anchor test to be adequately representative…
Schiebener, Johannes; Wegmann, Elisa; Pawlikowski, Mirko; Brand, Matthias
2012-11-01
Models of decision making postulate that interactions between contextual conditions and characteristics of the decision maker determine decision-making performance. We tested this assumption by using a possible positive contextual influence (goals) and a possible negative contextual influence (anchor) in a risky decision-making task (Game of Dice Task, GDT). In this task, making advantageous choices is well known to be closely related to a specific decision maker variable: the individual level of executive functions. One hundred subjects played the GDT in one of four conditions: with self-set goal for final balance (n = 25), with presentation of an anchor (a fictitious Top 10 list, showing high gains of other participants; n = 25), with anchor and goal definition (n = 25), and with neither anchor nor goal setting (n = 25). Subjects in the conditions with anchor made more risky decisions irrespective of the negative feedback, but this anchor effect was influenced by goal monitoring and moderated by the level of the subjects' executive functions. The findings imply that impacts of situational influences on decision making as they frequently occur in real life depend upon the individual's cognitive abilities. Anchor effects can be overcome by subjects with good cognitive abilities.
Stability Calculation Method of Slope Reinforced by Prestressed Anchor in Process of Excavation
Li, Zhong; Wei, Jia; Yang, Jun
2014-01-01
This paper takes the effect of supporting structure and anchor on the slope stability of the excavation process into consideration; the stability calculation model is presented for the slope reinforced by prestressed anchor and grillage beam, and the dynamic search model of the critical slip surface also is put forward. The calculation model of the optimal stability solution of each anchor tension of the whole process is also given out, through which the real-time analysis and checking of slope stability in the process of excavation can be realized. The calculation examples indicate that the slope stability is changed with the dynamic change of the design parameters of anchor and grillage beam. So it is relatively more accurate and reasonable by using dynamic search model to determine the critical slip surface of the slope reinforced by prestressed anchor and grillage beam. Through the relationships of each anchor layout and the slope height of various stages of excavation, and the optimal stability solution of prestressed bolt tension design value in various excavation stages can be obtained. The arrangement of its prestressed anchor force reflects that the layout of the lower part of bolt and the calculation of slope reinforcement is in line with the actual. These indicate that the method is reasonable and practical. PMID:24683319
Stability calculation method of slope reinforced by prestressed anchor in process of excavation.
Li, Zhong; Wei, Jia; Yang, Jun
2014-01-01
This paper takes the effect of supporting structure and anchor on the slope stability of the excavation process into consideration; the stability calculation model is presented for the slope reinforced by prestressed anchor and grillage beam, and the dynamic search model of the critical slip surface also is put forward. The calculation model of the optimal stability solution of each anchor tension of the whole process is also given out, through which the real-time analysis and checking of slope stability in the process of excavation can be realized. The calculation examples indicate that the slope stability is changed with the dynamic change of the design parameters of anchor and grillage beam. So it is relatively more accurate and reasonable by using dynamic search model to determine the critical slip surface of the slope reinforced by prestressed anchor and grillage beam. Through the relationships of each anchor layout and the slope height of various stages of excavation, and the optimal stability solution of prestressed bolt tension design value in various excavation stages can be obtained. The arrangement of its prestressed anchor force reflects that the layout of the lower part of bolt and the calculation of slope reinforcement is in line with the actual. These indicate that the method is reasonable and practical.
Granular Simulation of NEO Anchoring
NASA Technical Reports Server (NTRS)
Mazhar, Hammad
2011-01-01
NASA is interested in designing a spacecraft capable of visiting a Near Earth Object (NEO), performing experiments, and then returning safely. Certain periods of this mission will require the spacecraft to remain stationary relative to the NEO. Such situations require an anchoring mechanism that is compact, easy to deploy and upon mission completion, easily removed. The design philosophy used in the project relies on the simulation capability of a multibody dynamics physics engine. On Earth it is difficult to create low gravity conditions and testing in low gravity environments, whether artificial or in space is costly and therefore not feasible. Through simulation, gravity can be controlled with great accuracy, making it ideally suited to analyze the problem at hand. Using Chrono::Engine [1], a simulation package capable of utilizing massively parallel GPU hardware, several validation experiments will be performed. Once there is sufficient confidence, modeling of the NEO regolith interaction will begin after which the anchor tests will be performed and analyzed. The outcome of this task is a study with an analysis of several different anchor designs, along with a recommendation on which anchor is better suited to the task of anchoring. With the anchors tested against a range of parameters relating to soil, environment and anchor penetration angles/velocities on a NEO.
Development and Assessment of a New CFRP Rod Anchor System for Prestressed Concrete
NASA Astrophysics Data System (ADS)
Al-Mayah, A.; Soudki, K.; Plumtree, A.
2006-09-01
Design concepts and experimental assessment of a new wedge anchor system for prestressing CFRP rods are presented. This compact and reusable anchor consists of an outer cylinder (barrel), a number of wedges, and a soft metal sleeve. The contacting surfaces of the wedges and barrel have a circular profile along the length of the anchor. Tensile testing using different presetting loads, geometric configurations, and rod sizes was carried out. The relationship of the tensile load and displacement of the rod was established. Presetting was found unnecessary since the anchor system was found to be capable of carrying the full design strength of the rods.
What do you do when you have a loose screw?
Brady, Paul C; Arrigoni, Paolo; Burkhart, Stephen S
2006-09-01
This study seeks to compare the pullout strength of various anchor configurations in an osteoporotic bone model. We have tested and present here a technique designed to augment the pullout resistance of an anchor in poor-quality bone with the use of a second anchor as an interference fit; this report describes our in vivo results with this procedure. Four groups of suture anchor constructs were tested. These included a single 5.0-mm Bio-Corkscrew (Arthrex, Naples, FL) (group I), a single 5.5-mm Bio-Corkscrew FT (fully threaded; Arthrex, Naples, FL) (group II), a single 6.5-mm Bio-Corkscrew (Arthrex, Naples, FL) (group III), and an interference fit of two 5.0-mm Bio-Corkscrew suture anchors (group IV). Anchors were secured in a 10-lb/ft3 polyurethane foam block to simulate osteoporotic bone. Each construct was cycled, then was pulled to failure with an Instron testing device (Instron, Canton, MA); measurements regarding cyclic displacement, yield load, and extension at yield load were recorded. During the in vivo portion of the study, the interference fit technique was performed in 18 shoulder arthroscopy cases in which a loose screw was a matter of concern. After the technique was performed, both anchors were pulled so their security could be assessed; cuff repair then proceeded normally. Biomechanical study: In terms of yield load, every anchor construct was significantly different from every other construct. Specifically, pullout strength increased significantly as follows: group I was the weakest against pullout (176 +/- 13 N), group III (223 +/- 17 N) was significantly stronger than group I, group II (247 +/- 12 N) was significantly stronger than group III, and, finally, group IV (305 +/- 16 N) was significantly stronger than group II. The only statistically significant difference in terms of cyclic displacement was that group IV (1.4 mm +/- 0.2) had significantly less displacement than group III (1.9 mm +/- 0.3). No significant differences in extension at yield load were observed among any of the groups. In vivo study: The interference anchor technique was used in 18 of 24 loose screw situations over a 6-month period. In all 18 of these cases (100%), a stable dual-anchor construct was achieved. All anchors were stable to the tug test, and none failed during knot tying or at any time during the procedure. From the perspective of strength against pullout, the strongest suture construct of those tested in the osteoporotic bone model was the dual-anchor-against-an-anchor interference fit construct. The next strongest anchor tested was the 5.5-mm Bio-Corkscrew FT, followed by the 6.5-mm Bio-Corkscrew, and, finally, the 5.0-mm Bio-Corkscrew. Each group was statistically different from every other group in terms of pullout strength. The interference fit construct was not only the strongest in vitro, but it performed well in the in vivo setting, offering the added benefit of additional sutures to be used for securing a cuff defect. This study gives the arthroscopic surgeon important data for use in planning what to do when a loose screw is encountered. Data from this study may be useful for the arthroscopic surgeon in choosing the proper anchor construct for osteoporotic bone. This study also lends support to the technique of press-fitting an anchor against an anchor in the loose screw situation.
Design procedures of retrofitted bridge rail.
DOT National Transportation Integrated Search
2016-08-01
The use of shallow embedment anchors in concrete is essential for retrofit applications; however, the combination of steel anchors, chemical adhesive, and concrete acting as a single tensile mechanism creates uncertainties in anchor strength and fail...
Permanent Ground Anchors : Nicholson Design Criteria
DOT National Transportation Integrated Search
1982-09-01
This study discusses the methods used by Nicholson Construction Company in the design of permanent ground anchors specifically as related to retaining walls. Basic soil parameters, design concepts, drilling and grouting methods for ground anchors are...
Bhagatji, Pinkesh; Leventis, Rania; Comeau, Jonathan; Refaei, Mohammad
2009-01-01
Diverse glycosylphosphatidylinositol (GPI)-anchored proteins enter mammalian cells via the clathrin- and dynamin-independent, Arf1-regulated GPI-enriched early endosomal compartment/clathrin-independent carrier endocytic pathway. To characterize the determinants of GPI protein targeting to this pathway, we have used fluorescence microscopic analyses to compare the internalization of artificial lipid-anchored proteins, endogenous membrane proteins, and membrane lipid markers in Chinese hamster ovary cells. Soluble proteins, anchored to cell-inserted saturated or unsaturated phosphatidylethanolamine (PE)-polyethyleneglycols (PEGs), closely resemble the GPI-anchored folate receptor but differ markedly from the transferrin receptor, membrane lipid markers, and even protein-free PE-PEGs, both in their distribution in peripheral endocytic vesicles and in the manner in which their endocytic uptake responds to manipulations of cellular Arf1 or dynamin activity. These findings suggest that the distinctive endocytic targeting of GPI proteins requires neither biospecific recognition of their GPI anchors nor affinity for ordered-lipid microdomains but is determined by a more fundamental property, the steric bulk of the lipid-anchored protein. PMID:19687251
Sun, Shanshan; Xue, Yejian; Wang, Qin; Li, Shihua; Huang, Heran; Miao, He; Liu, Zhaoping
2017-07-11
Nanosheet-constructing porous CeO 2 microspheres with silver nanoparticles anchored on the surface were developed as a highly efficient oxygen reduction reaction (ORR) catalyst. The aluminum-air batteries applying Ag-CeO 2 as the ORR catalyst exhibit a high output power density and low degradation rate of 345 mW cm -2 and 2.6% per 100 h, respectively.
Variations on a theme of Lander and Waterman
DOE Office of Scientific and Technical Information (OSTI.GOV)
Speed, T.
1997-12-01
The original Lander and Waterman mathematical analysis was for fingerprinting random clones. Since that time, a number of variants of their theory have appeared, including ones which apply to mapping by anchoring random clones, and to non-random or directed clone mapping. The same theory is now widely used to devise random sequencing strategies. In this talk I will review these developments, and go on the discuss the theory required for directed sequencing strategies.
ERIC Educational Resources Information Center
Chen, Haiwen; Holland, Paul
2009-01-01
In this paper, we develop a new chained equipercentile equating procedure for the nonequivalent groups with anchor test (NEAT) design under the assumptions of the classical test theory model. This new equating is named chained true score equipercentile equating. We also apply the kernel equating framework to this equating design, resulting in a…
Unifying physical concepts of reality
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilbert, T.L.
1983-08-01
Physics may be characterized as the science of matter and energy. It anchors the two ends of the frontiers of science: the frontier of the very small and the frontier of the very large. All of the phenomena that we observe and study at the frontiers of science - all external experiences - are manifestations of matter and energy. One may, therefore, use physics to exemplify both the diversity and unity of science. This theme will be developed in two separate examples: first by sketching, very briefly, the historical origins of frontiers of the very small and very large andmore » the converging unity of these two frontiers; and then by describing certain unifying concepts that play a central role in physics and provide a framework for relating developments in different sciences.« less
NASA Astrophysics Data System (ADS)
Živić, I.; Elezović-Hadžić, S.; Milošević, S.
2018-01-01
We have studied the adsorption problem of self-attracting linear polymers, modeled by self-avoiding walks (SAWs), situated on three-dimensional fractal structures, exemplified by 3d Sierpinski gasket (SG) family of fractals as containers of a poor solvent. Members of SG family are enumerated by an integer b (b ≥ 2), and it is assumed that one side of each SG fractal is an impenetrable adsorbing surface. We calculate the critical exponents γ1 ,γ11, and γs, which are related to the numbers of all possible SAWs with one, both, and no ends anchored to the adsorbing boundary, respectively. By applying the exact renormalization group (RG) method (for the first three members of the SG fractal family, b = 2 , 3, and 4), we have obtained specific values of these exponents, for θ-chain and globular polymer phase. We discuss their mutual relations and relations with corresponding values pertinent to extended polymer chain phase.
Ma, Chunrong; Zhang, Weimin; He, Yu-Shi; Gong, Qiang; Che, Haiying; Ma, Zi-Feng
2016-02-21
Hierarchically structured carbon coated SnO2 nanoparticles well-anchored on the surface of a CNT (C-SnO2/CNT) material were synthesized by a facile hydrothermal process and subsequent carbonization. The as-obtained C-SnO2/CNT hybrid, when applied as an anode material for lithium ion batteries (LIBs), showed a high reversible capacity up to 1572 mA h g(-1) at 200 mA g(-1) with a superior rate capability (685 mA h g(-1) at 4000 mA g(-1)). Even after 100 charge/discharge cycles at 1000 mA g(-1), a specific capacity of 1100 mA h g(-1) can still be maintained. Such impressive electrochemical performance can be mainly attributed to the hierarchical sandwiched structure and strong synergistic effects of the ultrafine SnO2 nanoparticles and the carbon coating, and thus presents this material a promising anode material for LIBs.
Cilia-like structures anchor the amphioxus notochord to its sheath.
Bočina, Ivana; Ljubešić, Nikola; Saraga-Babić, Mirna
2011-01-01
Body stiffness is important during undulatory locomotion in fish. In amphioxus, the myosepta play an important role in transmission of muscular forces to the notochord. In order to define the specific supporting role of the notochord in amphioxus during locomotion, the ultrastructure of 10 adult amphioxus specimens was analyzed using transmission electron microscopy. Numerous cilia-like structures were found on the surface of each notochordal cell at the sites of their attachment to the notochordal sheath. Ultrastructurally, these structures consisted of the characteristic arrangement of peripheral and central microtubular doublets and were anchored to the inner layer of the notochordal sheath. Immunohistochemically, a positive reaction to applied dynein and β-tubulin antibodies characterized the area of the cilia-like structures. We propose that reduced back-and-forth movements of the cilia-like structures might contribute to the flow of the fluid content inside the notochord, thus modulating the stiffness of the amphioxus body during its undulatory locomotion. Copyright © 2009 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Parashar, Sweta
2018-05-01
We present density functional theory-nonequilibrium Green’s function method for electron transport of dipyridazine and dipyridimine molecular junctions with gold, copper and nickel electrodes. Our investigation reveals that the junctions formed with gold and copper electrodes bridging dipyridazine molecule through thiol anchoring group enhance current as compared to the junctions in which the molecule and electrode were coupled directly. Further, nickel electrode displays weak decrease of current with increase of voltage at about 1.2 V. The result is fully rationalized by means of the distribution of molecular orbitals as well as shift in molecular energy levels and HOMO-LUMO gap with applied bias voltage. Our findings are compared with theoretical and experimental results available for other molecular junctions. Present results predict potential avenues for changing the transport behavior by not only changing the electrodes, but also the position of nitrogen atom and type of anchoring-atom that connect molecule and electrodes, thus extending applications of dipyridazine and dipyridimine molecule in future integrated circuits.
ChromA: signal-based retention time alignment for chromatography–mass spectrometry data
Hoffmann, Nils; Stoye, Jens
2009-01-01
Summary: We describe ChromA, a web-based alignment tool for chromatography–mass spectrometry data from the metabolomics and proteomics domains. Users can supply their data in open and standardized file formats for retention time alignment using dynamic time warping with different configurable local distance and similarity functions. Additionally, user-defined anchors can be used to constrain and speedup the alignment. A neighborhood around each anchor can be added to increase the flexibility of the constrained alignment. ChromA offers different visualizations of the alignment for easier qualitative interpretation and comparison of the data. For the multiple alignment of more than two data files, the center-star approximation is applied to select a reference among input files to align to. Availability: ChromA is available at http://bibiserv.techfak.uni-bielefeld.de/chroma. Executables and source code under the L-GPL v3 license are provided for download at the same location. Contact: stoye@techfak.uni-bielefeld.de Supplementary information: Supplementary data are available at Bioinformatics online. PMID:19505941
Harada, Ichiro; Kim, Sung-Gon; Cho, Chong Su; Kurosawa, Hisashi; Akaike, Toshihiro
2007-01-01
In this study, a simple combined method consisting of floating and anchored collagen gel in a ligament or tendon equivalent culture system was used to produce the oriented fibrils in fibroblast-populated collagen matrices (FPCMs) during the remodeling and contraction of the collagen gel. Orientation of the collagen fibrils along single axis occurred over the whole area of the floating section and most of the fibroblasts were elongated and aligned along the oriented collagen fibrils, whereas no significant orientation of fibrils was observed in normally contracted FPCMs by the floating method. Higher elasticity and enhanced mechanical strength were obtained using our simple method compared with normally contracted floating FPCMs. The Young's modulus and the breaking point of the FPCMs were dependent on the initial cell densities. This simple method will be applied as a convenient bioreactor to study cellular processes of the fibroblasts in the tissues with highly oriented fibrils such as ligaments or tendons. (c) 2006 Wiley Periodicals, Inc.
Clathrin-independent pathways do not contribute significantly to endocytic flux
Bitsikas, Vassilis; Corrêa, Ivan R; Nichols, Benjamin J
2014-01-01
Several different endocytic pathways have been proposed to function in mammalian cells. Clathrin-coated pits are well defined, but the identity, mechanism and function of alternative pathways have been controversial. Here we apply universal chemical labelling of plasma membrane proteins to define all primary endocytic vesicles, and labelling of specific proteins with a reducible SNAP-tag substrate. These approaches provide high temporal resolution and stringent discrimination between surface-connected and intracellular membranes. We find that at least 95% of the earliest detectable endocytic vesicles arise from clathrin-coated pits. GPI-anchored proteins, candidate cargoes for alternate pathways, are also found to enter the cell predominantly via coated pits. Experiments employing a mutated clathrin adaptor reveal distinct mechanisms for sorting into coated pits, and thereby explain differential effects on the uptake of transferrin and GPI-anchored proteins. These data call for a revision of models for the activity and diversity of endocytic pathways in mammalian cells. DOI: http://dx.doi.org/10.7554/eLife.03970.001 PMID:25232658
ERIC Educational Resources Information Center
Li, Yanmei
2012-01-01
In a common-item (anchor) equating design, the common items should be evaluated for item parameter drift. Drifted items are often removed. For a test that contains mostly dichotomous items and only a small number of polytomous items, removing some drifted polytomous anchor items may result in anchor sets that no longer resemble mini-versions of…
ERIC Educational Resources Information Center
Kim, Sooyeon; Walker, Michael E.
2011-01-01
This study examines the use of subpopulation invariance indices to evaluate the appropriateness of using a multiple-choice (MC) item anchor in mixed-format tests, which include both MC and constructed-response (CR) items. Linking functions were derived in the nonequivalent groups with anchor test (NEAT) design using an MC-only anchor set for 4…
Not all Anchors Weigh Equally.
Greenstein, Michael; Velazquez, Alexandra
2017-11-01
The anchoring bias is a reliable effect wherein a person's judgments are affected by initially presented information, but it is unknown specifically why this effect occurs. Research examining this bias suggests that elements of both numeric and semantic priming may be involved. To examine this, the present research used a phenomenon wherein people treat numeric information presented differently in Arabic numeral or verbal formats. We presented participants with one of many forms of an anchor that represented the same value (e.g., twelve hundred or 1,200). Thus, we could examine how a concept's meaning and its absolute numeric value affect anchoring. Experiments 1 and 2 showed that people respond to Arabic and verbal anchors differently. Experiment 3 showed that these differences occurred largely because people tend to think of numbers in digit format. This suggests that one's conceptual understanding of the anchored information matters more than its strict numeric value.
Can anchor models explain inverted-U effects in facial judgments?
Mignault, Alain; Bhaumik, Arijit; Chaudhuri, Avi
2009-06-01
Researchers in a variety of disciplines have found that participants take less time and generate less diversity of responses when judging stimuli towards the ends of a scale than when judging those near the center. Three types of models, connectionist, exemplar, and anchor models, can account for these inverted-U effects. Anchor models assume that stimuli near the ends of the scale are used as anchors to compare with the other stimuli, implying that anchor representations are activated for each judgment. Therefore, participants should learn the anchors better than the other stimuli. Participants were 40 students from the Department of Psychology at McGill University (5 men; M age = 20.5 yr.; SD = 1.7). The experiment involved two tasks: first participants judged facial gender and then performed a recognition task. The results showed no correlation between the position on the gender scale and recognition accuracy. Several hypotheses were offered to explain these results.
Anchoring submersible ultrasonic receivers in river channels with stable substrate
Bettoli, Phillip William; Scholten, G.D.; Hubbs, D.
2010-01-01
We developed an anchoring system for submersible ultrasonic receivers (SURs) that we placed on the bottom of the riverine reaches of three main-stem reservoirs in the upper Tennessee River. Each anchor consisted of a steel tube (8.9 x 35.6 cm) welded vertically to a round plate of steel (5.1 x 40.6 cm). All seven SURs and their 57-kg anchors were successfully deployed and retrieved three times over 547 d by a dive team employing surface air-breathing equipment and a davit-equipped boat. All of the anchors and their SURs remained stationary over two consecutive winters on the hard-bottom, thalweg sites where they were deployed. The SUR and its anchor at the most downriver site experienced flows that exceeded 2,100 m(3)/s and mean water column velocities of about 0.9 m/s.
Stadler, J; Keenan, T W; Bauer, G; Gerisch, G
1989-01-01
The contact site A glycoprotein, a cell adhesion protein of aggregating Dictyostelium cells, was labeled with fatty acid, myo-inositol, phosphate and ethanolamine in vivo, indicating that the protein is anchored in the membrane by a lipid. This lipid was not susceptible to phosphatidyl inositol specific phospholipase C. When cleaved with nitrous acid or when subjected to acetolysis, the anchor released lipids which were different from those released from Trypanosoma variant cell surface glycoprotein, a protein with a known phosphatidyl inositol-glycan anchor. Resistance to weak and sensitivity to strong alkali indicated that the fatty acid in the contact site A glycolipid anchor was in an amide bond. On incubation with sphingomyelinase, a lipid with the chromatographic behavior of ceramide was released. These results suggest that the contact site A glycoprotein is anchored by a ceramide based lipid glycan. Images PMID:2721485
Muhs, Bart E; Jordan, William; Ouriel, Kenneth; Rajaee, Sareh; de Vries, Jean-Paul
2018-06-01
The objective of this study was to examine whether prophylactic use of EndoAnchors (Medtronic, Santa Rosa, Calif) contributes to improved outcomes after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms through 2 years. The Aneurysm Treatment Using the Heli-FX Aortic Securement System Global Registry (ANCHOR) subjects who received prophylactic EndoAnchors during EVAR were considered for this analysis. Imaging data of retrospective subjects who underwent EVAR at ANCHOR enrolling institutions were obtained to create a control sample. Nineteen baseline anatomic measurements were used to perform propensity score matching, yielding 99 matched pairs. Follow-up imaging of the ANCHOR and control cohorts was then compared to examine outcomes through 2 years, using Kaplan-Meier survival analysis. Freedom from type Ia endoleak was 97.0% ± 2.1% in the ANCHOR cohort and 94.1% ± 2.5% in the control cohort through 2 years (P = .34). The 2-year freedom from neck dilation in the ANCHOR and control cohorts was 90.4% ± 5.6% and 87.3% ± 4.3%, respectively (P = .46); 2-year freedom from sac enlargement was 97.0% ± 2.1% and 94.0% ± 3.0%, respectively (P = .67). No device migration was observed. Aneurysm sac regression was observed in 81.1% ± 9.5% of ANCHOR subjects through 2 years compared with 48.7% ± 5.9% of control subjects (P = .01). Cox regression analysis found an inverse correlation between number of hostile neck criteria met and later sac regression (P = .05). Preoperative neck thrombus circumference and infrarenal diameter were also variables associated with later sac regression, although not to a significant degree (P = .10 and P = .06, respectively). Control subjects with thrombus were significantly less likely to experience later sac regression than those without thrombus (6% and 43%, respectively; P = .001). In ANCHOR subjects, rate of regression was not significantly different in subjects with or without thrombus (33% and 36%, respectively; P = .82). Control subjects with wide aortic necks (>28 mm) were observed to experience sac regression at a lower rate than subjects with smaller diameter necks (10% and 44%, respectively; P = .004). Wide neck and normal neck subjects implanted with EndoAnchors experienced later sac regression at roughly equivalent rates (44% and 33%, respectively; P = .50). In propensity-matched cohorts of subjects undergoing EVAR, the rate of sac regression in subjects treated with EndoAnchors was significantly higher. EndoAnchors may mitigate the adverse effect of wide infrarenal necks and neck thrombus on sac regression, although further studies are needed to evaluate the long-term effect of EndoAnchors. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
ANTS-anchored Zn-Al-CO3-LDH particles as fluorescent probe for sensing of folic acid
NASA Astrophysics Data System (ADS)
Liu, Pengfei; Liu, Dan; Liu, Yanhuan; Li, Lei
2016-09-01
A novel fluorescent nanosensor for detecting folic acid (FA) in aqueous media has been developed based on 8-aminonaphthalene-1,3,6-trisulfonate (ANTS) anchored to the surface of Zn-Al-CO3-layered double hydroxides (LDH) particles. The nanosensor showed high fluorescence intensity and good photostability due to a strong coordination interaction between surface Zn2+ ions of Zn-Al-CO3-LDH and N atoms of ANTS, which were verified by result of X-ray photoelectron spectroscopy (XPS). ANTS-anchored on the surface of Zn-Al-CO3-LDH restricted the intra-molecular rotation leading to ANTS-anchored J-type aggregation emission enhancement. ANTS-anchored Zn-Al-CO3-LDH particles exhibited highly sensitive and selective response to FA over other common metal ions and saccharides present in biological fluids. The proposed mechanism was that oxygen atoms of -SO3 groups in ANTS-anchored on the surface of Zn-Al-CO3-LDH were easily collided by FA molecules to form potential hydrogen bonds between ANTS-anchored and FA molecules, which could effectively quench the ANTS-anchored fluorescence. Under the simulated physiological conditions (pH of 7.4), the fluorescence quenching was fitted to Stern-Volmer equation with a linear response in the concentration range of 1 μM to 200 μM with a limit of detection of 0.1 μM. The results indicate that ANTS-anchored Zn-Al-CO3-LDH particles can afford a very sensitive system for the sensing FA in aqueous solution.
Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors.
Tompkins, Marc; Monchik, Keith O; Plante, Matthew J; Fleming, Braden C; Fadale, Paul D
2011-10-01
To evaluate whether the use of knotless lateral anchors in a suture bridge construct produces better contact area and pressure parameters than a suture bridge construct with standard lateral anchors that require knots or a double-row repair. The hypothesis was that knotless lateral anchors would produce better contact area and pressure parameters than the other two constructs. A total of fifteen matched pairs of cadaveric shoulders were divided into three groups. In Group 1, a suture bridge using knotless anchors for the lateral row was performed on five shoulders. A suture bridge using standard lateral row anchors that require knots was performed on the contralateral shoulders. In Group 2, suture bridge with knotless lateral row anchors was compared with double-row repair. In Group 3, suture bridge using standard lateral row anchors was compared with double-row repair. The contact conditions of the rotator cuff footprint were measured using pressure-sensitive film. There were no statistically significant differences between any of the techniques regarding contact area F(2, 15.7) = 3.09, P = 0.07 or mean contact pressure F(2, 15.1) = 2.35, P = 0.12. A post hoc power analysis suggests differences between techniques are likely less than 91-113 mm(2) for area and 0.071-0.089 N for pressure. The use of knotless anchors in the lateral row of a suture bridge repair did not increase the footprint contact area or contact pressure when compared to a suture bridge repair requiring knots laterally or to a double-row repair.
Anchor enhanced capsulorraphy in bunionectomies using an L-shaped capsulotomy.
Gould, John S; Ali, Sheriff; Fowler, Rachel; Fleisig, Glenn S
2003-01-01
The objective of this study was to investigate potential benefit of a suture anchor-enhanced capsulorraphy in the early maintenance of correction in bunionectomies. We compared, retrospectively, in successive series, the loss of correction of the Hallux Valgus (HV) and intermetatarsal (IM) angle, in those repaired with an L-shaped capsulorraphy enhanced with anchors to those without. Intraoperative and second week postoperative simulated weightbearing anterior posterior (AP) X-rays were used to evaluate results. By using only intraoperative and early postoperative X-rays, we should have effectively eliminated extraneous factors that might have influenced our results. A Total of 106 cases were investigated, 65 of which were repaired using anchors, the remaining 41 without. In the anchor group, 38 underwent a proximal metatarsal concentric shelf osteotomy (CSO)/modified McBride procedure, while the remaining 27 had a distal Chevron correction. In the without-anchor group, 21 had a CSO/modified McBride procedure while 20 underwent the Chevron procedure. In the without-anchor group, the average HV and IM loss of correction was 4.60 degrees (range, -2 to 21 degrees) and 0.6 degrees (range, -1 to 9 degrees) respectively. In the anchor group, the corresponding loss was 2.8 degrees (range, -3 to 17 degrees) and 0.6 degrees (range, -2 to 14 degrees) respectively. These results, when statistically analyzed, demonstrated that while the IM angle change was not statistically significant, the HV angle change was statistically significant, implying that the anchor plays a significant role in maintaining the surgical correction in both the distal Chevron and CSO/ modified McBride bunionectomies.
Barz, W P; Walter, P
1999-04-01
Many eukaryotic cell surface proteins are anchored in the lipid bilayer through glycosylphosphatidylinositol (GPI). GPI anchors are covalently attached in the endoplasmic reticulum (ER). The modified proteins are then transported through the secretory pathway to the cell surface. We have identified two genes in Saccharomyces cerevisiae, LAG1 and a novel gene termed DGT1 (for "delayed GPI-anchored protein transport"), encoding structurally related proteins with multiple membrane-spanning domains. Both proteins are localized to the ER, as demonstrated by immunofluorescence microscopy. Deletion of either gene caused no detectable phenotype, whereas lag1Delta dgt1Delta cells displayed growth defects and a significant delay in ER-to-Golgi transport of GPI-anchored proteins, suggesting that LAG1 and DGT1 encode functionally redundant or overlapping proteins. The rate of GPI anchor attachment was not affected, nor was the transport rate of several non-GPI-anchored proteins. Consistent with a role of Lag1p and Dgt1p in GPI-anchored protein transport, lag1Delta dgt1Delta cells deposit abnormal, multilayered cell walls. Both proteins have significant sequence similarity to TRAM, a mammalian membrane protein thought to be involved in protein translocation across the ER membrane. In vivo translocation studies, however, did not detect any defects in protein translocation in lag1Delta dgt1Delta cells, suggesting that neither yeast gene plays a role in this process. Instead, we propose that Lag1p and Dgt1p facilitate efficient ER-to-Golgi transport of GPI-anchored proteins.
Barz, Wolfgang P.; Walter, Peter
1999-01-01
Many eukaryotic cell surface proteins are anchored in the lipid bilayer through glycosylphosphatidylinositol (GPI). GPI anchors are covalently attached in the endoplasmic reticulum (ER). The modified proteins are then transported through the secretory pathway to the cell surface. We have identified two genes in Saccharomyces cerevisiae, LAG1 and a novel gene termed DGT1 (for “delayed GPI-anchored protein transport”), encoding structurally related proteins with multiple membrane-spanning domains. Both proteins are localized to the ER, as demonstrated by immunofluorescence microscopy. Deletion of either gene caused no detectable phenotype, whereas lag1Δ dgt1Δ cells displayed growth defects and a significant delay in ER-to-Golgi transport of GPI-anchored proteins, suggesting that LAG1 and DGT1 encode functionally redundant or overlapping proteins. The rate of GPI anchor attachment was not affected, nor was the transport rate of several non–GPI-anchored proteins. Consistent with a role of Lag1p and Dgt1p in GPI-anchored protein transport, lag1Δ dgt1Δ cells deposit abnormal, multilayered cell walls. Both proteins have significant sequence similarity to TRAM, a mammalian membrane protein thought to be involved in protein translocation across the ER membrane. In vivo translocation studies, however, did not detect any defects in protein translocation in lag1Δ dgt1Δ cells, suggesting that neither yeast gene plays a role in this process. Instead, we propose that Lag1p and Dgt1p facilitate efficient ER-to-Golgi transport of GPI-anchored proteins. PMID:10198056
Lamar, Melissa; Ajilore, Olusola; Leow, Alex; Charlton, Rebecca; Cohen, Jamie; GadElkarim, Johnson; Yang, Shaolin; Zhang, Aifeng; Davis, Randall; Penney, Dana; Libon, David J; Kumar, Anand
2016-05-01
We investigated whether graphomotor organization during a digitized Clock Drawing Test (dCDT) would be associated with cognitive and/or brain structural differences detected with a tractography-derived structural connectome of the brain. 72 non-demented/non-depressed adults were categorized based on whether or not they used 'anchor' digits (i.e., 12, 3, 6, 9) before any other digits while completing dCDT instructions to "draw the face of a clock with all the numbers and set the hands to 10 after 11". 'Anchorers' were compared to 'non-anchorers' across dCDT, additional cognitive measures and connectome-based metrics. In the context of grossly intact clock drawings, anchorers required fewer strokes to complete the dCDT and outperformed non-anchorers on executive functioning and learning/memory/recognition tasks. Anchorers had higher local efficiency for the left medial orbitofrontal and transverse temporal cortices as well as the right rostral anterior cingulate and superior frontal gyrus versus non-anchorers suggesting better regional integration within local networks involving these regions; select aspects of which correlated with cognition. Results also revealed that anchorers' exhibited a higher degree of modular integration among heteromodal regions of the ventral visual processing stream versus non-anchorers. Thus, an easily observable graphomotor distinction was associated with 1) better performance in specific cognitive domains, 2) higher local efficiency suggesting better regional integration, and 3) more sophisticated modular integration involving the ventral ('what') visuospatial processing stream. Taken together, these results enhance our knowledge of the brain-behavior relationships underlying unprompted graphomotor organization during dCDT. Copyright © 2016 Elsevier Ltd. All rights reserved.
345. Caltrans, Photographer September 20, 1935 "WEST ANCHOR ARM"; DETAIL ...
345. Caltrans, Photographer September 20, 1935 "WEST ANCHOR ARM"; DETAIL VIEW OF CANTILEVER TRUSS WEST ANCHOR ARM UNDER CONSTRUCTION. 7-1023 - San Francisco Oakland Bay Bridge, Spanning San Francisco Bay, San Francisco, San Francisco County, CA
Poly-L/D-lactic acid anchors are associated with reoperation and failure of SLAP repairs.
Park, Min Jung; Hsu, Jason E; Harper, Carl; Sennett, Brian J; Huffman, G Russell
2011-10-01
This study investigates factors associated with failure and reoperation after glenoid labrum repair. We studied a nonconcurrent cohort of consecutive patients undergoing arthroscopic superior labrum repair at a single institution by 2 fellowship-trained surgeons over a 10-year period. There were 348 patients included in this study with a mean age of 33.4 years (95% confidence interval [CI], 32.1 to 35.9) and a mean clinical follow-up of 12.3 months (95% CI, 10.9 to 13.8). The overall reoperation rate was 6.3%, with a revision labrum repair rate of 4.3%. Subsequent surgery and failure after arthroscopic labrum repair were significantly correlated with Workers' Compensation claims (odds ratio [OR], 4.6; P < .001; 95% CI, 1.8 to 11.7), the use of tobacco (OR, 12.0; P = .03; 95% CI, 1.2 to 114.9), and the use of absorbable poly-L/D-lactic acid (PLDLA) anchors (100% correlation, P < .001). The OR for having repeat surgery was 12.7 (95% CI, 4.9 to 32.9; P < .001) with poly-96L/4D-lactic acid (Mini-Revo; Linvatec, Largo, FL) and also increased with the use of poly-70L/30D-lactic acid (Bio-Fastak and Bio-Suturetak; Arthrex, Naples, FL) anchor material (P = .04) after removal of the patients exposed to poly-96L/4D-lactic acid anchors. The rates of repeat surgery with PLDLA anchors from Linvatec and PLDLA anchors from Arthrex were 24% and 4%, respectively. None of the patients treated with nonabsorbable suture anchors (polyether ether ketone or metallic) returned to the operating room (P < .001). After we controlled for associated factors in a multivariate analysis, the use of absorbable anchors, in particular poly-96L/4D-lactic acid anchors (OR, 14.7; P < .001), and having a work-related injury (OR, 8.1; P < .001) remained independent factors associated with both repeat surgery and revision superior labrum repair. Bioabsorbable PLDLA anchor material led to significantly more SLAP repair failures and reoperations compared with nonabsorbable suture anchors. Our recommendation is that glenoid labrum repairs be performed with nondegradable material and, specifically, that the use of anchors composed of PLDLA material should be avoided. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Dierckman, Brian D; Goldstein, Jordan L; Hammond, Kyle E; Karas, Spero G
2012-01-01
The purpose of this study was to determine the maximum load and point of failure of the construct during tensioning of the lateral row of a transosseous-equivalent (TOE) rotator cuff repair. In 6 fresh-frozen human shoulders, a TOE rotator cuff repair was performed, with 1 suture from each medial anchor passed through the tendon and tied in a horizontal mattress pattern. One of 2 limbs from each of 2 medial anchors was pulled laterally over the tendon. After preparation of the lateral bone for anchor placement, the 2 limbs were passed through the polyether ether ketone (PEEK) eyelet of a knotless anchor and tied to a tensiometer. The lateral anchor was placed into the prepared bone tunnel but not fully seated. Tensioning of the lateral-row repair was simulated by pulling the tensiometer to tighten the suture limbs as they passed through the eyelet of the knotless anchor. The mode of failure and maximum tension were recorded. The procedure was then repeated for the second lateral-row anchor. The mean load to failure during lateral-row placement in the TOE model was 80.8 ± 21.0 N (median, 83 N; range, 27.2 to 115.8 N). There was no statistically significant difference between load to failure during lateral-row tensioning for the anterior and posterior anchors (P = .84). Each of the 12 constructs failed at the eyelet of the lateral anchor. Retrieval analysis showed no failure of the medial anchors, no medial suture cutout through the rotator cuff tendon, and no signs of gapping at the repair site. Our results suggest that the medial-row repair does not appear vulnerable during tensioning of the lateral row of a TOE rotator cuff repair with the implants tested. However, surgeons should exercise caution when tensioning the lateral row, especially when lateral-row anchors with PEEK eyelets are implemented. For this repair construct, the findings suggest that although the medial row is not vulnerable during lateral-row tensioning of a TOE rotator cuff repair, lateral-row anchors with PEEK eyelets appear vulnerable to early failure. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Suture anchor repair of quadriceps tendon rupture after total knee arthroplasty.
Kim, Tae Won B; Kamath, Atul F; Israelite, Craig L
2011-08-01
Disruption of the extensor mechanism after total knee arthroplasty (TKA) is a devastating complication, usually requiring surgical repair. Although suture anchor fixation is well described for repair of the ruptured native knee quadriceps tendon, no study has discussed the use of suture anchors in quadriceps repair after TKA. We present an illustrative case of successful suture anchor fixation of the quadriceps mechanism after TKA. The procedure has been performed in a total of 3 patients. A surgical technique and brief review of the literature follows. Suture anchor fixation of the quadriceps tendon is a viable option in the setting of rupture after TKA. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Demin, V. F.; Fofanov, O. B.; Demina, T. V.; Yavorskiy, V. V.
2017-02-01
Regularities of the change of the stress-strain state of coal containing rock masses, depending on mining-geological factors, were revealed. These factors allow establishing rational parameters of anchoring of wall rocks to enhance the stability of development workings. Specific conditions of the deflected mode, displays of rock pressure, terms of maintenance depending on technological parameters are investigated. Researches allowed determining the degree of their development influence on the efficiency of application of the anchoring of the hollow making and will allow a reasonable application of anchoring certificates, provide stability of the rocks mining and reduce expenses on its realization and maintenance.
Strauss, Eric J; Ishak, Charbel; Inzerillo, Christopher; Walsh, Michael; Yildirim, Gokce; Walker, Peter; Jazrawi, Laith; Rosen, Jeffrey
2007-08-01
To determine whether positioning of the tibia affects the degree of tibial external rotation seen during a dial test in the posterior cruciate ligament (PCL)-posterolateral corner (PLC)-deficient knee. Laboratory investigation. Biomechanics laboratory. An anterior force applied to the tibia in the combined PCL-PLC-deficient knee will yield increased tibial external rotation during a dial test. The degree of tibial external rotation was measured with 5 Nm of external rotation torque applied to the tibia at both 30 degrees and 90 degrees of knee flexion. Before the torque was applied, an anterior force, a posterior force, or neutral (normal, reduced control) force was applied to the tibia. External rotation measurements were repeated after sequential sectioning of the PCL, the posterolateral structures and the fibular collateral ligament (FCL). Baseline testing of the intact specimens demonstrated a mean external rotation of 18.6 degrees with the knee flexed to 30 degrees (range 16.1-21.0 degrees ), and a mean external rotation of 17.3 degrees with the knee flexed to 90 degrees (range 13.8-20.0 degrees ). Sequential sectioning of the PCL, popliteus and popliteofibular ligament, and the FCL led to a significant increase in tibial external rotation compared with the intact knee for all testing scenarios. After sectioning of the popliteus and popliteofibular ligament, the application of an anterior force during testing led to a mean tibial external rotation that was 5 degrees greater than during testing in the neutral position and 7.5 degrees greater than during testing with a posterior force. In the PCL, popliteus/popliteofibular ligament and FCL-deficient knee, external rotation was 9 degrees and 12 degrees greater with the application of an anterior force during testing compared with neutral positioning and the application of a posterior force, respectively. An anterior force applied to the tibia during the dial test in a combined PCL-PLC-injured knee increased the overall amount of observed tibial external rotation during the dial test. The anterior force reduced the posterior tibial subluxation associated with PCL injury, which is analogous to what is observed when the dial test is performed with the patient in the prone position. Reducing the tibia with either an anterior force when the patient is supine or performing the dial test with the patient in the prone position increases the ability of an examiner to detect a concomitant PLC injury in the setting of a PCL-deficient knee.
NASA Technical Reports Server (NTRS)
1983-01-01
These supertankers, riding at anchor off the coast of the United Arab Emirates, Gulf of Oman (25.5N, 56.5E) cast long shadows and eddy currents in the late afternoon sun. The ships are anchored just outside the Persian Gulf. Because of a surplus of supertankers in the world, many of them are simply moored in the Gulf of Oman where they can be safely anchored and yet be close to the oil ports when activated.
Anchorage Behaviors of Frictional Tieback Anchors in Silty Sand
NASA Astrophysics Data System (ADS)
Hsu, Shih-Tsung; Hsiao, Wen-Ta; Chen, Ke-Ting; Hu, Wen-Chi; Wu, Ssu-Yi
2017-06-01
Soil anchors are extensively used in geotechnical applications, most commonly serve as tieback walls in deep excavations. To investigate the anchorage mechanisms of this tieback anchor, a constitutive model that considers both strain hardening and softening and volume dilatancy entitled SHASOVOD model, and FLAC3D software are used to perform 3-D numerical analyses. The results from field anchor tests are compared with those calculated by numerical analyses to enhance the applicability of the numerical method. After the calibration, this research carried out the parameter studies by numerical analyses. The numerical results reveal that whether the yield of soil around an anchor develops to ground surface and/or touches the diaphragm wall depending on the overburden depth H and the embedded depth Z of an anchor, this study suggests the minimum overburden and embedded depths to avoid the yield of soils develop to ground surface and/or touch the diaphragm wall. When the embedded depth, overburden depth or fixed length of an anchor increases, the anchorage capacity also increases. Increasing fixed length should be the optimum method to increase the anchorage capacity for fixed length less than 20m. However, when the fixed length of an anchor exceeds 30 m, the increasing rate of anchorage capacity per fixed length decreases, and progressive yield occurs obviously between the fixed length and surrounding soil.
Cell Activation Mediated by Glycosylphosphatidylinositol-Anchored or Transmembrane Forms of CD14†
Pugin, J.; Kravchenko, V. V.; Lee, J.-D.; Kline, L.; Ulevitch, R. J.; Tobias, P. S.
1998-01-01
CD14 is a glycosylphosphatidylinositol (GPI)-anchored membrane glycoprotein which functions as a receptor on myeloid cells for ligands derived from microbial pathogens such as lipopolysaccharide (LPS). We have studied the importance of the GPI tail of CD14 in signalling with the promonocytic cell line THP-1 expressing recombinant CD14 in a GPI-anchored form (THP1-wtCD14 cells) or in a transmembrane form (THP1-tmCD14). We found that, like other GPI-anchored molecules, GPI-anchored CD14 was recovered mainly from a Triton X-100-insoluble fraction, whereas transmembrane CD14 was fully soluble in Triton X-100. LPS induced cell activation of THP1-wtCD14 and of THP1-tmCD14 (protein tyrosine kinase phosphorylation, NF-κB activation, and cytokine production) in a very similar manner. However, anti-CD14 antibody-induced cross-linking caused a rapid calcium mobilization signal only in GPI-anchored CD14 cells. Studies with pharmacologic inhibitors of intracellular signalling events implicate phospholipase C and protein tyrosine kinases in the genesis of this antibody-induced calcium signal. Our results suggest that GPI anchoring and CD14 targeting to glycolipid-rich membrane microdomains are not required for LPS-mediated myeloid cell activation. GPI anchoring may however be important for other signalling functions, such as those events reflected by antibody cross-linking. PMID:9488411
Cholesterol-dependent retention of GPI-anchored proteins in endosomes.
Mayor, S; Sabharanjak, S; Maxfield, F R
1998-01-01
Several cell surface eukaryotic proteins have a glycosylphosphatidylinositol (GPI) modification at the Cterminal end that serves as their sole means of membrane anchoring. Using fluorescently labeled ligands and digital fluorescence microscopy, we show that contrary to the potocytosis model, GPI-anchored proteins are internalized into endosomes that contain markers for both receptor-mediated uptake (e.g. transferrin) and fluid phase endocytosis (e.g. dextrans). This was confirmed by immunogold electron microscopy and the observation that a fluorescent folate derivative bound to the GPI-anchored folate receptor is internalized into the same compartment as co-internalized horseradish peroxidase-transferrin; the folate fluorescence was quenched when cells subsequently were incubated with diaminobenzidine and H2O2. Most of the GPI-anchored proteins are recycled back to the plasma membrane but at a rate that is at least 3-fold slower than C6-NBD-sphingomyelin or recycling receptors. This endocytic retention is regulated by the level of cholesterol in cell membranes; GPI-anchored proteins are recycled back to the cell surface at the same rate as recycling transferrin receptors and C6-NBD-sphingomyelin in cholesterol-depleted cells. Cholesterol-dependent endocytic sorting of GPI-anchored proteins is consistent with the involvement of specialized lipid domains or 'rafts' in endocytic sorting. These results provide an alternative explanation for GPI-requiring functions of some GPI-anchored proteins. PMID:9707422
Turner, Lauren Senty; Kanamoto, Taisei; Unoki, Takeshi; Munro, Cindy L.; Wu, Hui; Kitten, Todd
2009-01-01
Streptococcus sanguinis is a member of the viridans group of streptococci and a leading cause of the life-threatening endovascular disease infective endocarditis. Initial contact with the cardiac infection site is likely mediated by S. sanguinis surface proteins. In an attempt to identify the proteins required for this crucial step in pathogenesis, we searched for surface-exposed, cell wall-anchored proteins encoded by S. sanguinis and then used a targeted signature-tagged mutagenesis (STM) approach to evaluate their contributions to virulence. Thirty-three predicted cell wall-anchored proteins were identified—a number much larger than those found in related species. The requirement of each cell wall-anchored protein for infective endocarditis was assessed in the rabbit model. It was found that no single cell wall-anchored protein was essential for the development of early infective endocarditis. STM screening was also employed for the evaluation of three predicted sortase transpeptidase enzymes, which mediate the cell surface presentation of cell wall-anchored proteins. The sortase A mutant exhibited a modest (∼2-fold) reduction in competitiveness, while the other two sortase mutants were indistinguishable from the parental strain. The combined results suggest that while cell wall-anchored proteins may play a role in S. sanguinis infective endocarditis, strategies designed to interfere with individual cell wall-anchored proteins or sortases would not be effective for disease prevention. PMID:19703977
Turner, Lauren Senty; Kanamoto, Taisei; Unoki, Takeshi; Munro, Cindy L; Wu, Hui; Kitten, Todd
2009-11-01
Streptococcus sanguinis is a member of the viridans group of streptococci and a leading cause of the life-threatening endovascular disease infective endocarditis. Initial contact with the cardiac infection site is likely mediated by S. sanguinis surface proteins. In an attempt to identify the proteins required for this crucial step in pathogenesis, we searched for surface-exposed, cell wall-anchored proteins encoded by S. sanguinis and then used a targeted signature-tagged mutagenesis (STM) approach to evaluate their contributions to virulence. Thirty-three predicted cell wall-anchored proteins were identified-a number much larger than those found in related species. The requirement of each cell wall-anchored protein for infective endocarditis was assessed in the rabbit model. It was found that no single cell wall-anchored protein was essential for the development of early infective endocarditis. STM screening was also employed for the evaluation of three predicted sortase transpeptidase enzymes, which mediate the cell surface presentation of cell wall-anchored proteins. The sortase A mutant exhibited a modest (approximately 2-fold) reduction in competitiveness, while the other two sortase mutants were indistinguishable from the parental strain. The combined results suggest that while cell wall-anchored proteins may play a role in S. sanguinis infective endocarditis, strategies designed to interfere with individual cell wall-anchored proteins or sortases would not be effective for disease prevention.
Sustained load performance of adhesive anchor systems in concrete
NASA Astrophysics Data System (ADS)
Davis, Todd Marshall
Stemming from a tragic failure of an adhesive anchor system, this research project investigated the sustained load performance of adhesive anchors in concrete under different installation and in-service conditions. The literature review investigated the current state of art of adhesive anchors. Extensive discussion was devoted to the behavior of adhesive anchors in concrete as well as the many factors that can affect their short-term and sustained load strength. Existing standards and specifications for the testing, design, construction, and inspection of adhesive anchors were covered. Based on the results of the literature review and the experience of the research group, a triage was conducted on many parameters identified as possibly affecting the sustained load performance of adhesive anchors and the highest priority parameters were investigated in this project. A stress versus time-to-failure approach was used to evaluate sensitivity of three ICC-ES AC 308 approved adhesive anchor systems. Of the various parameters investigated, only elevated in-service temperature and manufacturer's cure time was shown to exhibit adverse effects on sustained loads more than that predicted by short-term tests of fully cured adhesive over a reasonable structure lifetime of 75 years. In a related study, various tests were conducted on the adhesive alone (time-temperature superposition, time-stress superposition, and dogbone tensile tests). The results of that study were used to investigate the existence of a correlation with long-term anchor pullout testing in concrete. No consistent correlations were detected for the adhesives in the study. Tests were also conducted on the effect of early-age concrete on adhesive anchor bond strength. On the basis of confined test bond-strength alone, adhesive A (vinyl ester) did not show any significant increase after 14 days (102% of 28 day strength at 14 days), and adhesive B and C (epoxies) did not show any significant increase after 7 days (104% and 93% of 28 days strength at 7 days respectively). The results of this research were used to draft recommended standards and specifications for AASHTO pertaining to testing, design, construction, and inspection of adhesive anchors in concrete for transportation structures. These draft standards were not included in this dissertation.
Brown, Christopher A; Hurwit, Daniel; Behn, Anthony; Hunt, Kenneth J
2014-02-01
Anatomic repair is indicated for patients who have recurrent lateral ankle instability despite nonoperative measures. There is no difference in repair stiffness, failure torque, or failure angle between specimens repaired with all-soft suture anchors versus the modified Broström-Gould technique with sutures only. Controlled laboratory study. In 10 matched pairs of human cadaveric ankles, the anterior talofibular ligament (ATFL) was incised from its origin on the fibula. After randomization, 1 ankle was repaired to its anatomic insertion using two 1.4-mm JuggerKnot all-soft suture anchors; the other ankle was repaired with a modified Broström-Gould technique using 2-0 FiberWire. All were augmented using the inferior extensor retinaculum. All ankles were mounted to the testing machine in 20° of plantar flexion and 15° of internal rotation and loaded to failure after the repair. Stiffness, failure torque, and failure angle were recorded and compared using a paired Student t test with a significance level set at P < .05. There was no significant difference in failure torque, failure angle, or stiffness. No anchors pulled out of bone. The primary mode of failure was pulling through the ATFL tissue. There was no statistical difference in strength or stiffness between a 1.4-mm all-soft suture anchor and a modified Broström-Gould repair with 2-0 FiberWire. The primary mode of failure was at the tissue level rather than knot failure or anchor pullout. The particular implant choice (suture only, tunnel, anchor) in repairing the lateral ligament complex may not be as important as the time to biological healing. The suture-only construct as described in the Broström-Gould repair was as strong as all-soft suture anchors, and the majority of the ankles failed at the tissue level. For those surgeons whose preference is to use anchor repair, this novel all-soft suture anchor may be an alternative to other larger anchors, as none failed by pullout.
Königshausen, M; Jettkant, B; Sverdlova, N; Ehlert, C; Gessmann, J; Schildhauer, T A; Seybold, D
2015-01-01
There is no biomechanical basis to determine the influence of different length of the central peg of the baseplate anchored within the native scapula in glenoid defect reconstruction in cases of degenerative or posttraumatic glenoid bone loss in reversed shoulder arthroplasty. The purpose of this study was to analyse the stability of different peg lengths used in glenoid bone loss in reversed shoulder arthroplasty. Different lengths of metaglene pegs with different depths of peg anchorage performed with or without metaglene screws in sawbone foam blocks were loaded in vertical and horizontal directions for differentiating load capacities. Simulated physiological loadings were then applied to the peg implants to determine the limits of loading in each depth of anchorage. The loading capacity of the implant was reduced as less of the peg was anchored. The vertically loaded implants showed a significantly higher stability, in contrast to those loaded horizontally at a corresponding peg length and depth of anchorage (p < 0.05). The tests revealed that the metaglene screws are more essential for primary stability than is the peg particularly in the vertically directed loadings (2/3 anchored: peg contributed to 28% of the stability, 1/3 anchorage: peg contributed to 12%). Under the second test conditions, the lowest depth of peg anchorage (1/3) resulted in 322 Newtons [N] in the long peg with a vertical loading direction, and in 130 N in the long peg with a horizontal loading direction (p < 0.05). The pegs should be anchored as deeply as possible into the native scapula bone stock. The metaglene screws play a major role in the initial stability, in contrast to the peg, and they become more important when the depth of the peg anchorage is reduced. If possible, four metaglene screws should be used in cases of uncontained bone loss to guarantee the highest stability.
Rudershausen, Paul J.; Buckel, Jeffrey A.; Hightower, Joseph E.
2013-01-01
We estimated survival rates of discarded black sea bass (Centropristis striata) in various release conditions using tag–recapture data. Fish were captured with traps and hook and line from waters 29–34 m deep off coastal North Carolina, USA, marked with internal anchor tags, and observed for release condition. Fish tagged on the bottom using SCUBA served as a control group. Relative return rates for trap-caught fish released at the surface versus bottom provided an estimated survival rate of 0.87 (95% credible interval 0.67–1.18) for surface-released fish. Adjusted for results from the underwater tagging experiment, fish with evidence of external barotrauma had a median survival rate of 0.91 (0.69–1.26) compared with 0.36 (0.17–0.67) for fish with hook trauma and 0.16 (0.08–0.30) for floating or presumably dead fish. Applying these condition-specific estimates of survival to non-tagging fishery data, we estimated a discard survival rate of 0.81 (0.62–1.11) for 11 hook and line data sets from waters 20–35 m deep and 0.86 (0.67–1.17) for 10 trap data sets from waters 11–29 m deep. The tag-return approach using a control group with no fishery-associated trauma represents a method to accurately estimate absolute discard survival of physoclistous reef species.
Biodegradable airway stents in infants - Potential life-threatening pitfalls.
Sztanó, B; Kiss, G; Márai, K; Rácz, G; Szegesdi, I; Rácz, K; Katona, G; Rovó, L
2016-12-01
The solution of severe tracheobronchial obstructions in early childhood means a great challenge. Biodegradable stents were intended to be a minimally invasive temporary solution which may decrease the number of interventions and limit the possible complications of stenting procedures. However, our first experiences have brought out a new, - especially in childhood - potentially life-threatening complication of this concept. Five SX-ELLA biodegradable polydioxanone stents was applied in three patients because of severe tracheobronchial obstruction: congenital tracheomalacia (7 day-old), acquired tracheomalacia (10 month-old), and congenital trachea-bronchomalacia (10 month-old). The breathing of all children improved right after the procedure. We observed degradation of the stent from the 5th postoperative week which resulted in large intraluminar fragments causing significant airway obstruction: one patient died of severe pneumonia, the other baby required urgent bronchoscopy to remove the obstructing 'foreign body' from the trachea. In the third case repeated stent placements successfully maintained the tracheal lumen. Polydioxanone stents may offer an alternative to metallic or silastic stents for collapse or external compression of the trachea in children; however, large decaying fragments mean a potential risk especially in the small size pediatric airway. The fragmentation of the stent, which generally starts in the 4-6 postoperative weeks, may create large sharp pieces. These may be anchored to the mucosa and covered by crust leading to obstruction. As repeated interventions are required, we do not consider the application of biodegradable stents unambiguously advantageous. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Steel shear strength of anchors with stand-off base plates.
DOT National Transportation Integrated Search
2013-09-01
Sign and signal structures are often connected to concrete foundations through a stand-off annular base plate with a double-nut anchor bolt connection, which leaves exposed anchor bolt lengths below leveling nuts used in these connections. Cantilever...
Determination of the space-charge field amplitude in polymeric photorefractive polymers.
Hwang, Ui-Jung; Choi, Chil-Sung; Vuong, Nguyen Quoc; Kim, Nakjoong
2005-12-22
The space-charge field built in a polymeric photorefractive polymer was calculated by a simple method based on the oriented gas model. When anisotropic chromophores in a photorefractive polymer were exposed to an external field, they oriented preferentially to exhibit a birefringence. Then, under illumination of two coherent beams and an external field, they reoriented to form a photorefractive grating. During the formation of the grating, the chromophores were reoriented by the space-charge field as well as by the external applied field. The birefringence induced in the material by an external electric field was determined by measuring the transmittance of the sample which is placed between crossed polarizers, where birefringence depicts the orientation of the chromophores. By measuring the diffraction efficiency with a modified degenerate four-wave mixing setup, the index amplitude of the grating was determined. Finally, the space-charge field was determined by comparing the diffraction efficiency with the birefringence with respect to the applied electric field. In our study, the space-charge field was about 20% of the external applied field, which coincided with previous results obtained from our laboratory.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-22
... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-ORD-2009-0694; FRL-9442-8] Notice of Availability of the External Review Draft of the Guidance for Applying Quantitative Data to Develop Data-Derived Extrapolation... Quantitative Data to Develop Data-Derived Extrapolation Factors for Interspecies and Intraspecies Extrapolation...
Modified Kidner procedure utilizing a Mitek bone anchor.
Dawson, D M; Julsrud, M E; Erdmann, B B; Jacobs, P M; Ringstrom, J B
1998-01-01
The recent development of small bone suture anchors has created several potential applications in reconstructive surgery of the foot. Mitek bone anchors are simple to insert, require less aggressive dissection and surgical time than reefing of the redundant posterior tibial tendon, and are a reliable method of tendon-to-bone fixation. Mitek bone anchors are an excellent technique for the treatment of redundant tibialis posterior tendon following a modified Kidner procedure. In modified Kidner procedures involving an excessively large os tibiale externum, Mitek anchoring of the redundant tibialis posterior tendon to the navicular bone is an excellent means for secure plication of the posterior tibial tendon in cases involving intraoperative tendon laxity. A description of the Mitek Anchor System and technique of application in a modified Kinder procedure is presented. The purpose of this study was to describe patient satisfaction and long-term clinical outcomes of the modified Kinder procedure with and without the Mitek bone anchoring system. A retrospective study of the modified Kinder procedure was performed with 13 patients being evaluated, seven with Mitek anchoring and six without. The University of Maryland 100-point Painful Foot Center Scoring System was modified to be more specific to the modified Kinder procedure for assessment of subjective long-term results. Patient overall satisfaction was rated good to excellent by 85.6% of patients in the Mitek group and by 100% of patients in the non-Mitek group. Use of the Mitek anchor allowed for quicker postoperative recovery to resumption of ambulation without assistive devices (average of 3 weeks vs. 4.42 weeks) and a quicker return to pain-free ambulation in normal shoegear (average of 4 weeks vs. 6 weeks). Mitek anchoring of the tibialis posterior tendon, theoretically, increases medial arch support as evidenced by 14% of the Mitek group and 67% of the non-Mitek group requiring postoperative orthotics.
Evaluation of mitral valve replacement anchoring in a phantom
NASA Astrophysics Data System (ADS)
McLeod, A. Jonathan; Moore, John; Lang, Pencilla; Bainbridge, Dan; Campbell, Gordon; Jones, Doug L.; Guiraudon, Gerard M.; Peters, Terry M.
2012-02-01
Conventional mitral valve replacement requires a median sternotomy and cardio-pulmonary bypass with aortic crossclamping and is associated with significant mortality and morbidity which could be reduced by performing the procedure off-pump. Replacing the mitral valve in the closed, off-pump, beating heart requires extensive development and validation of surgical and imaging techniques. Image guidance systems and surgical access for off-pump mitral valve replacement have been previously developed, allowing the prosthetic valve to be safely introduced into the left atrium and inserted into the mitral annulus. The major remaining challenge is to design a method of securely anchoring the prosthetic valve inside the beating heart. The development of anchoring techniques has been hampered by the expense and difficulty in conducting large animal studies. In this paper, we demonstrate how prosthetic valve anchoring may be evaluated in a dynamic phantom. The phantom provides a consistent testing environment where pressure measurements and Doppler ultrasound can be used to monitor and assess the valve anchoring procedures, detecting pararvalvular leak when valve anchoring is inadequate. Minimally invasive anchoring techniques may be directly compared to the current gold standard of valves sutured under direct vision, providing a useful tool for the validation of new surgical instruments.
An Accessory Protein Required for Anchoring and Assembly of Amyloid Fibers in B. subtilis Biofilms
Romero, Diego; Vlamakis, Hera; Losick, Richard; Kolter, Roberto
2011-01-01
Cells within Bacillus subtilis biofilms are held in place by an extracellular matrix that contains cell-anchored amyloid fibers, composed of the amyloidogenic protein TasA. As biofilms age they disassemble because the cells release the amyloid fibers. This release appears to be the consequence of incorporation of D-tyrosine, D-leucine, D-tryptophan and D-methionine into the cell wall. Here, we characterize the in vivo roles of an accessory protein TapA (TasA anchoring/assembly protein; previously YqxM) that serves both to anchor the fibers to the cell wall and to assemble TasA into fibers. TapA is found in discrete foci in the cell envelope and these foci disappear when cells are treated with a mixture of D-amino acids. Purified cell wall sacculi retain a functional form of this anchoring protein such that purified fibers can be anchored to the sacculi in vitro. In addition, we show that TapA is essential for the proper assembly of the fibers. Its absence results in a dramatic reduction in TasA levels and what little TasA is left produces only thin fibers that are not anchored to the cell. PMID:21477127
An accessory protein required for anchoring and assembly of amyloid fibres in B. subtilis biofilms.
Romero, Diego; Vlamakis, Hera; Losick, Richard; Kolter, Roberto
2011-06-01
Cells within Bacillus subtilis biofilms are held in place by an extracellular matrix that contains cell-anchored amyloid fibres, composed of the amyloidogenic protein TasA. As biofilms age they disassemble because the cells release the amyloid fibres. This release appears to be the consequence of incorporation of D-tyrosine, D-leucine, D-tryptophan and D-methionine into the cell wall. Here, we characterize the in vivo roles of an accessory protein TapA (TasA anchoring/assembly protein; previously YqxM) that serves both to anchor the fibres to the cell wall and to assemble TasA into fibres. TapA is found in discrete foci in the cell envelope and these foci disappear when cells are treated with a mixture of D-amino acids. Purified cell wall sacculi retain a functional form of this anchoring protein such that purified fibres can be anchored to the sacculi in vitro. In addition, we show that TapA is essential for the proper assembly of the fibres. Its absence results in a dramatic reduction in TasA levels and what little TasA is left produces only thin fibres that are not anchored to the cell. © 2011 Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Vabbilisetty, Pratima
For decades, lipid vesicular bodies such as liposomes have been widely used and explored as biomimetic models of cell membranes and as drug/gene delivery carrier systems. Similarly, micellar iron oxide nanoparticles have also been investigated as potential MRI agents as well as drug delivery carrier systems. Cell surface carbohydrate-protein interactions allow them to serve as markers for recognition of many molecular and cellular activities thereby, are exploited as attractive molecules for surface modification of nanocarrier systems with purpose for tissues specific targeting and biocompatibility. In addition, the cell lipid membrane serves as an important platform for occurrence of many biological processes that are governed and guided by cell surface receptors. Introduction of chemoselective functional groups, via bio-orthogonal conjugation strategies, at the cell surface facilitates many cellular modifications and paves path for novel and potential biomedical applications. Anchoring lipids are needed for liposome surface functionalization with ligands of interest and play important roles in ligand grafting density, liposomes stability and biological activity. On the other hand, anchoring lipids are also needed for cell surface re-engineering by lipid fusion approach and have high impact for ligand insertion efficiency and biological activity. Overall, in this dissertation study, functional anchoring lipids for glyco-functionalized carrier systems and for efficient cell surface re-engineering applications were systematically investigated, respectively. Firstly, investigation of the synthesis of glyco-functionalized liposome systems based on phosphatidylethonalamine (PE) and cholesterol (Chol) anchoring lipids, prepared by post chemically selective functionalization via Staudinger ligation were carried out. The effect of anchor lipids on the stability, encapsulation and releasing capacity of the glycosylated liposomes were investigated by dynamic light scattering (DLS) technique and by entrapping 5, 6-carboxyfluorescein (CF) dye and monitoring the fluorescence leakage, respectively. Overall, the Chol-anchored liposomes showed faster releasing rate than DSPE-anchored liposomes. This could be due to the increase in rigidity of the lipid membrane upon inclusion of Chol, thereby, leading to fast leakage of liposomes. Second, the potential effects of phospholipid (PE) and cholesterol (Chol)-based anchor lipids on cell surface re-engineering via copper free click chemistry were assessed with RAW 264.7 cells as model. The confocal microscopy and flow cytometry results indicated the successful incorporation of biotinylated Chol-based anchor lipids after specific streptavidin-FITC binding onto the cell surface. Higher fluorescence intensities from the cell membrane were observed for Chol-based anchor lipids when compared to DSPE as anchoring lipid. Furthermore, cytotoxicity of the synthesized biotinylated anchor lipids on the RAW 264.7 cells was assessed by MTT assay. The MTT assay results further confirmed that cell surface re-engineering via lipid anchoring approach strategy has very little or negligible amount of cytotoxicity on the cell viability. Thus, this study suggests the possible use of these lipids for potential cell surface re-engineering applications. In addition, synthesis of lipid coated iron oxide nanoparticles via dual solvent exchange approach and their glyco-functionalization via Staudinger ligation were investigated and characterized by FT-IR and TEM techniques. The stability of iron oxide nanoparticles with varying compositions of lipid anchors was evaluated by dynamic light scattering technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kardanpour, Reihaneh; Tangestaninejad, Shahram, E-mail: stanges@sci.ui.ac.ir; Mirkhani, Valiollah, E-mail: mirkhani@sci.ui.ac.ir
2016-03-15
Efficient synthesis of various benzimidazoles and benzothiazoles under mild conditions catalyzed by Cu(II) anchored onto UiO-66–NH{sub 2} metal organic framework is reported. In this manner, first, the aminated UiO-66 was modified with thiophene-2-carbaldehyde and then the prepared Schiff base was reacted with CuCl{sub 2}. The prepared catalyst was characterized by FT-IR, UV–vis, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), N{sub 2} adsorption, inductively coupled plasma atomic emission spectroscopy (ICP-AES) and field emission scanning electron microscopy (FE-SEM). The UiO-66–NH{sub 2}–TC–Cu was applied as a highly efficient catalyst for synthesis of benzimidazole and benzothiazole derivatives by the reaction of aldehydes with 1,2-diaminobenzenemore » or 2-aminothiophenol. The Cu(II)-containing MOF was reused several times without any appreciable loss of its efficiency. - Graphical abstract: Efficient synthesis of benzimidazoles and benzothiazoles catalyzed by Cu(II) anchored onto UiO-66–NH{sub 2} metal organic framework is reported. - Highlights: • A copper Schiff base was immobilized on UiO-66 via postsynthetic modification. • The modified MOFs were fully characterized by a variety of methods. • The catalyst was used for the preparation of benzimidazoles and benzothiazoles. • In comparison of other catalysts, our catalyst was more efficient and forceful.« less
Poly(vinyl alcohol) hydrogel coatings with tunable surface exposure of hydroxyapatite
Moreau, David; Villain, Arthur; Ku, David N; Corté, Laurent
2014-01-01
Insufficient bone anchoring is a major limitation of artificial substitutes for connective osteoarticular tissues. The use of coatings containing osseoconductive ceramic particles is one of the actively explored strategies to improve osseointegration and strengthen the bone-implant interface for general tissue engineering. Our hypothesis is that hydroxyapatite (HA) particles can be coated robustly on specific assemblies of PVA hydrogel fibers for the potential anchoring of ligament replacements. A simple dip-coating method is described to produce composite coatings made of microscopic hydroxyapatite (HA) particles dispersed in a poly(vinyl alcohol) (PVA) matrix. The materials are compatible with the requirements for implant Good Manufacturing Practices. They are applied to coat bundles of PVA hydrogel fibers used for the development of ligament implants. By means of optical and electronic microscopy, we show that the coating thickness and surface state can be adjusted by varying the composition of the dipping solution. Quantitative analysis based on backscattered electron microscopy show that the exposure of HA at the coating surface can be tuned from 0 to over 55% by decreasing the weight ratio of PVA over HA from 0.4 to 0.1. Abrasion experiments simulating bone-implant contact illustrate how the coating cohesion and wear resistance increase by increasing the content of PVA relative to HA. Using pullout experiments, we find that these coatings adhere well to the fiber bundles and detach by propagation of a crack inside the coating. These results provide a guide to select coated implants for anchoring artificial ligaments. PMID:25482413
Mining Tasks from the Web Anchor Text Graph: MSR Notebook Paper for the TREC 2015 Tasks Track
2015-11-20
Mining Tasks from the Web Anchor Text Graph: MSR Notebook Paper for the TREC 2015 Tasks Track Paul N. Bennett Microsoft Research Redmond, USA pauben...anchor text graph has proven useful in the general realm of query reformulation [2], we sought to quantify the value of extracting key phrases from...anchor text in the broader setting of the task understanding track. Given a query, our approach considers a simple method for identifying a relevant
Engineered liquid crystal anchoring energies with nanopatterned surfaces.
Gear, Christopher; Diest, Kenneth; Liberman, Vladimir; Rothschild, Mordechai
2015-01-26
The anchoring energy of liquid crystals was shown to be tunable by surface nanopatterning of periodic lines and spaces. Both the pitch and height were varied using hydrogen silsesquioxane negative tone electron beam resist, providing for flexibility in magnitude and spatial distribution of the anchoring energy. Using twisted nematic liquid crystal cells, it was shown that this energy is tunable over an order of magnitude. These results agree with a literature model which predicts the anchoring energy of sinusoidal grooves.
The effect of social marketing communication on safe driving.
Yang, Dong-Jenn; Lin, Wan-Chen; Lo, Jyue-Yu
2011-12-01
Processing of cognition, affect, and intention was investigated in viewers of advertisements to prevent speeding while driving. Results indicated that anchoring-point messages had greater effects on viewers' cognition, attitude, and behavioral intention than did messages without anchoring points. Further, the changes in message anchoring points altered participants' perceptions of acceptable and unacceptable judgments: a higher anchoring point in the form of speeding mortality was more persuasive in promoting the idea of reducing driving speed. Implications for creation of effective safe driving communications are discussed.
Normalization of relative and incomplete temporal expressions in clinical narratives.
Sun, Weiyi; Rumshisky, Anna; Uzuner, Ozlem
2015-09-01
To improve the normalization of relative and incomplete temporal expressions (RI-TIMEXes) in clinical narratives. We analyzed the RI-TIMEXes in temporally annotated corpora and propose two hypotheses regarding the normalization of RI-TIMEXes in the clinical narrative domain: the anchor point hypothesis and the anchor relation hypothesis. We annotated the RI-TIMEXes in three corpora to study the characteristics of RI-TMEXes in different domains. This informed the design of our RI-TIMEX normalization system for the clinical domain, which consists of an anchor point classifier, an anchor relation classifier, and a rule-based RI-TIMEX text span parser. We experimented with different feature sets and performed an error analysis for each system component. The annotation confirmed the hypotheses that we can simplify the RI-TIMEXes normalization task using two multi-label classifiers. Our system achieves anchor point classification, anchor relation classification, and rule-based parsing accuracy of 74.68%, 87.71%, and 57.2% (82.09% under relaxed matching criteria), respectively, on the held-out test set of the 2012 i2b2 temporal relation challenge. Experiments with feature sets reveal some interesting findings, such as: the verbal tense feature does not inform the anchor relation classification in clinical narratives as much as the tokens near the RI-TIMEX. Error analysis showed that underrepresented anchor point and anchor relation classes are difficult to detect. We formulate the RI-TIMEX normalization problem as a pair of multi-label classification problems. Considering only RI-TIMEX extraction and normalization, the system achieves statistically significant improvement over the RI-TIMEX results of the best systems in the 2012 i2b2 challenge. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Grant, John A; Bissell, Benjamin; Hake, Mark E; Miller, Bruce S; Hughes, Richard E; Carpenter, James E
2012-11-01
The suture anchor and transosseous drill hole techniques for reattachment of the distal biceps tendon to the radius have been found to have similar clinical and biomechanical outcomes. However, a comparison of the cost effectiveness of these techniques is lacking. The purpose of this study was to determine whether the use of suture anchors decreases operative time enough to offset the additional cost of the implants. The records of all patients undergoing a distal biceps tendon reattachment were reviewed to determine the method of fixation, operative time, and associated surgical costs. Two surgeons used a technique of fixing the tendon directly to the bone (transosseous group), whereas 3 surgeons used suture anchors. Given the standard nature of the surgical procedure (other than the fixation technique), only the costs that differed between the 2 groups were included. Surgical center costs were obtained from the local outpatient surgical center in 2011 US dollars. Five surgeons treated 70 men (mean age, 45.9±9.2 years). Mean time from injury to surgery was 14 days. Mean operative times for the transosseous and suture anchor groups were 97.6±14.9 and 95.8±25.8 minutes, respectively (P=.74). Two anchors were used in 79% of the anchor cases. The use of anchors cost $474.33 more per patient. However, this value is sensitive to the cost of the individual anchors, intersurgeon variation in operative time, and per-minute value of saved operative time. No operative time was saved with the use of suture anchors. This cost comparison framework can be used to evaluate the balance in surgical resource use due to implant cost vs savings in operative time. Copyright 2012, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Niroumand, Hamed; Kassim, Khairul Anuar
2014-03-01
Uplift response of symmetrical anchor plates with and without grid fixed reinforced (GFR) reinforcement was evaluated in model tests and numerical simulations by Plaxis. Many variations of reinforcement layers were used to reinforce the sandy soil over symmetrical anchor plates. In the current research, different factors such as relative density of sand, embedment ratios, and various GFR parameters including size, number of layers, and the proximity of the layer to the symmetrical anchor plate were investigated in a scale model. The failure mechanism and the associated rupture surface were observed and evaluated. GFR, a tied up system made of fiber reinforcement polymer (FRP) strips and end balls, was connected to the geosynthetic material and anchored into the soil. Test results showed that using GFR reinforcement significantly improved the uplift capacity of anchor plates. It was found that the inclusion of one layer of GFR, which rested directly on the top of the anchor plate, was more effective in enhancing the anchor capacity itself than other methods. It was found that by including GFR the uplift response was improved by 29%. Multi layers of GFR proved more effective in enhancing the uplift capacity than a single GFR reinforcement. This is due to the additional anchorage provided by the GFR at each level of reinforcement. In general, the results show that the uplift capacity of symmetrical anchor plates in loose and dense sand can be significantly increased by the inclusion of GFR. It was also observed that the inclusion of GFR reduced the requirement for a large L/D ratio to achieve the required uplift capacity. The laboratory and numerical analysis results are found to be in agreement in terms of breakout factor and failure mechanism pattern.
2015-08-01
crimping alone is insufficient. Hydro-mulch shall be applied using a color dye and the manufacturer’s recommended rate of an organic tackifier. D...drainage areas where erosion is probable. All erosion control blanket shall be 100% biodegradable , net- free, wood fiber (excelsior) or coconut...Manufactured biodegradable stakes (6-inch minimum) or wooden stakes (8-inch minimum) shall be used to anchor any erosion materials; metal staples
Traction Aid for Wheeled Vehicles
1975-07-01
driver’s position in the load vehicle to assist him in applying constant braking loads, 4) a drum and line fifth wheel sys- tem attached to the load...in Alaskan snow, and the results were so encouraging that further testing of the device was requested. In comparison to tire chains, the Tyr-Trac...vehicle with the end of the line anchored and the speed of the line played off the drum measuring the actual vehicle speed. An eight channel
NASA's International Lunar Network Anchor Nodes and Robotic Lunar Lander Project Update
NASA Technical Reports Server (NTRS)
Cohen, Barbara A.; Bassler, Julie A.; Ballard, Benjamin; Chavers, Greg; Eng, Doug S.; Hammond, Monica S.; Hill, Larry A.; Harris, Danny W.; Hollaway, Todd A.; Kubota, Sanae;
2010-01-01
NASA Marshall Space Flight Center and The Johns Hopkins University Applied Physics Laboratory have been conducting mission studies and performing risk reduction activities for NASA's robotic lunar lander flight projects. Additional mission studies have been conducted to support other objectives of the lunar science and exploration community and extensive risk reduction design and testing has been performed to advance the design of the lander system and reduce development risk for flight projects.
Seppel, Gernot; Saier, Tim; Martetschläger, Frank; Plath, Johannes E; Guevara-Alvarez, Alberto; Henschel, Julia; Winkler, Martin; Augat, Peter; Imhoff, Andreas B; Buchmann, Stefan
2017-12-01
Fractures of the humeral greater tuberosity (GT) are a frequent injury progressively treated with arthroscopic suture anchor repair. Yet, no biomechanical study has been performed comparing fixation strength of arthroscopic single- (SR) vs. double row (DR) fixation. Standardized fractures of the greater tuberosity were created in 12 fresh frozen proximal humeri. After random assignation to the SR or DR group the fixed humeri were tested applying cyclic loading to the supraspinatus and infraspinatus tendon. Load to failure and fragment displacement were assessed by means of an electrodynamic material testing machine using an optical tracking system. Load to failure values were higher in the DR group (649 N; ±176) than in the SR group (490 N; ±145) however without statistical significance (p = .12). In greater tuberosity displacement of 3-5 mm surgical treatment is recommended. The fixing constructs in this study did not reach displacement landmarks of 3 or 5 mm before construct failure as shown in previous studies. Thus the applied traction force (N) at 1 mm displacement was analyzed. In the SR group the load at 1 mm displacement was 277 N; ±46 compared to 260 N; ±62 in the DR group (p = .65). The results suggest that both techniques are viable options for refixation of greater tuberosity fractures. Laboratory study.
Treatment of Class II malocclusion with mandibular skeletal anchorage.
Cakir, Ezgi; Malkoç, Siddik; Kirtay, Mustafa
2017-06-01
The aim of this case report was to present the dentofacial changes obtained with bone anchorage in a Class II patient with moderate to severe crowding. A boy, aged 14.5 years, with a dolichofacial type, convex profile, and skeletal and dental Class II relationships was examined. After evaluation, functional treatment with bone anchorage and 4 first premolar extractions was decided as the treatment approach. Miniplates were placed on the buccal shelves of the mandibular third molars. The hook of the anchor was revealed from the first molar level. After surgery, the 4 first premolars were extracted to retract the protrusive mandibular incisors. The maxillary and mandibular first molars were banded, and a lip bumper was inserted to apply elastics and to help distalize the maxillary first molars. Orthodontic forces of 300 to 500 g were applied immediately after placement, originating from the miniscrews to the hooks of the appliance to advance the mandible. After 20 months of treatment, the patient had a dental and skeletal Class I relationship, the mandible was advanced, the maxilla was restrained, and overjet was decreased. The combination of a bone anchor, Class II elastics, and an inner bow is a promising alternative to functional treatment, along with extractions, in Class II patients. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.
Hayeri, Mohammad Reza; Keefe, Daniel T; Chang, Eric Y
2016-05-01
Rotator cuff repair using a suture bridge and knotless suture anchors is a relatively new, but increasingly used technique. The suture bridge technique creates an anatomically similar and more secure rotator cuff repair compared with conventional arthroscopic techniques and the use of knotless anchors eliminates the challenges associated with knot tying during arthroscopic surgery. However, previous in vitro biomechanical tests have shown that the hold of the suture in a knotless suture anchor is far lower than the pullout strength of the anchor from bone. Up until now slippage has been a theoretical concern. We present a prospectively diagnosed case of in vivo suture loosening after rotator cuff repair using a knotless bridge technique resulting in subacromial-subdeltoid bursitis.
Career Anchors: Results of an Organisational Study in the UK.
ERIC Educational Resources Information Center
Yarnall, Jane
1998-01-01
Career anchors of 374 British employees were identified using Schein's questionnaire. Age, gender, and length of service had no significant effect on distribution of anchors. Job level had some relationship. The information could be used to determine appropriate career-development strategies. (SK)
Schaerer, Michael; Swaab, Roderick I; Galinsky, Adam D
2015-02-01
The current research shows that having no power can be better than having a little power. Negotiators prefer having some power (weak negotiation alternatives) to having no power (no alternatives). We challenge this belief that having any alternative is beneficial by demonstrating that weak alternatives create low anchors that reduce the value of first offers. In contrast, having no alternatives is liberating because there is no anchor to weigh down first offers. In our experiments, negotiators with no alternatives felt less powerful but made higher first offers and secured superior outcomes compared with negotiators who had weak alternatives. We established the role of anchoring through mediation by first offers and through moderation by showing that weak alternatives no longer led to worse outcomes when negotiators focused on a countervailing anchor or when negotiators faced an opponent with a strong alternative. These results demonstrate that anchors can have larger effects than feelings of power. Absolute powerlessness can be psychologically liberating. © The Author(s) 2014.
Harrison, Noel; Field, John R; Quondamatteo, Fabio; Curtin, William; McHugh, Peter E; Mc Donnell, Pat
2014-09-01
A new surface architecture for cementless orthopaedic implants (OsteoAnchor), which incorporates a multitude of tiny anchor features for enhancing primary fixation, was tested in an ovine hemi-arthroplasty pilot study. Test animals were implanted with a hip stem component incorporating the OsteoAnchor surface architecture produced using additive layer manufacturing and control animals were implanted with stems containing a standard plasma sprayed titanium coating. Intra-operative surgeon feedback indicated that superior primary fixation was achieved for the OsteoAnchor stems and rapid return to normal gait and load bearing was observed post-operation. Following a 16-week recovery time, histological evaluation of the excised femurs revealed in-growth of healthy bone into the porous structure of the OsteoAnchor stems. Bone in-growth was not achieved for the plasma sprayed stems. These results indicate the potential for the OsteoAnchor surface architecture to enhance both the initial stability and long term lifetime of cementless orthopaedic implants. Copyright © 2014 Elsevier Ltd. All rights reserved.
Hydroxamate anchors for improved photoconversion in dye-sensitized solar cells.
Brewster, Timothy P; Konezny, Steven J; Sheehan, Stafford W; Martini, Lauren A; Schmuttenmaer, Charles A; Batista, Victor S; Crabtree, Robert H
2013-06-03
We present the first analysis of performance of hydroxamate linkers as compared to carboxylate and phosphonate groups when anchoring ruthenium-polypyridyl dyes to TiO2 surfaces in dye-sensitized solar cells (DSSCs). The study provides fundamental insight into structure/function relationships that are critical for cell performance. Our DSSCs have been produced by using newly synthesized dye molecules and characterized by combining measurements and simulations of experimental current density-voltage (J-V) characteristic curves. We show that the choice of anchoring group has a direct effect on the overall sunlight-to-electricity conversion efficiency (η), with hydroxamate anchors showing the best performance. Solar cells based on the pyridyl-hydroxamate complex exhibit higher efficiency since they suppress electron transfer from the photoanode to the electrolyte and have superior photoinjection characteristics. These findings suggest that hydroxamate anchoring groups should be particularly valuable in DSSCs and photocatalytic applications based on molecular adsorbates covalently bound to semiconductor surfaces. In contrast, analogous acetylacetonate anchors might undergo decomposition under similar conditions suggesting limited potential in future applications.
La Manna, G; Donno, Y; Sarà, G; Ceccherelli, G
2015-01-15
Posidonia oceanica (L.) Delile meadows are recognized as priority habitat for conservation by the EU Habitats Directive. The La Maddalena Archipelago National Park (Mediterranean Sea) P. oceanica meadow, the dominant coastal habitat of the area, is mostly threatened by boat anchoring. 12 years after the establishment of mooring fields and anchoring restrictions, a study was conducted to measure their effectiveness on the conservation of seagrass and the mitigation of anchoring damage. We found that: (i) the condition of P. oceanica was disturbed, both in the mooring fields and in control locations; (ii) mooring fields and anchoring restrictions did not show to be an efficient system for the protection of seagrass, in fact anchor scars increased after the tourist season; (iii) the mooring systems had an impact on the surrounding area of the meadow, probably due to their misuse. On the basis of these results, management recommendations for marine parks are proposed. Copyright © 2014 Elsevier Ltd. All rights reserved.
Placement of temperature probe in bovine vagina for continuous measurement of core-body temperature.
Lee, C N; Gebremedhin, K G; Parkhurst, A; Hillman, P E
2015-09-01
There has been increasing interest to measure core-body temperature in cattle using internal probes. This study examined the placement of HOBO water temperature probe with an anchor, referred to as the "sensor pack" (Hillman et al. Appl Eng Agric ASAE 25(2):291-296, 2009) in the vagina of multiparous Holstein cows under grazing conditions. Two types of anchors were used: (a) long "fingers" (4.5-6 cm), and (b) short "fingers" (3.5 cm). The long-finger anchors stayed in one position while the short-finger anchors were not stable in one position (rotate) within the vagina canal and in some cases came out. Vaginal temperatures were recorded every minute and the data collected were then analyzed using exponential mixed model regression for non-linear data. The results showed that the core-body temperatures for the short-finger anchors were lower than the long-finger anchors. This implied that the placement of the temperature sensor within the vagina cavity may affect the data collected.
Placement of temperature probe in bovine vagina for continuous measurement of core-body temperature
NASA Astrophysics Data System (ADS)
Lee, C. N.; Gebremedhin, K. G.; Parkhurst, A.; Hillman, P. E.
2015-09-01
There has been increasing interest to measure core-body temperature in cattle using internal probes. This study examined the placement of HOBO water temperature probe with an anchor, referred to as the "sensor pack" (Hillman et al. Appl Eng Agric ASAE 25(2):291-296, 2009) in the vagina of multiparous Holstein cows under grazing conditions. Two types of anchors were used: (a) long "fingers" (4.5-6 cm), and (b) short "fingers" (3.5 cm). The long-finger anchors stayed in one position while the short-finger anchors were not stable in one position (rotate) within the vagina canal and in some cases came out. Vaginal temperatures were recorded every minute and the data collected were then analyzed using exponential mixed model regression for non-linear data. The results showed that the core-body temperatures for the short-finger anchors were lower than the long-finger anchors. This implied that the placement of the temperature sensor within the vagina cavity may affect the data collected.
Purcell, Amanda; Fleming, Jennifer; Bennett, Sally; Burmeister, Bryan; Haines, Terry
2010-03-01
The Multidimensional Fatigue Inventory (MFI) is a commonly used cancer-related fatigue assessment tool. Unlike other fatigue assessments, there are no published minimal clinically important difference (MCID) criteria for the MFI in cancer populations. MCID criteria determine the smallest change in scores that can be regarded as important, allowing clinicians and researchers to interpret the meaning of changes in patient's fatigue scores. This research aims to improve the clinical utility of the MFI by establishing MCID criteria for the MFI sub-scales in a radiotherapy population. Two hundred ten patients undergoing radiotherapy were recruited to a single-centre prospective cohort study. Patients were assessed at three time points, at the start of radiotherapy, the end of radiotherapy and 6 weeks after radiotherapy completion. Assessment consisted of four clinically relevant constructs: (1) treatment impact on fatigue, (2) health-related quality of life, (3) performance status and (4) occupational productivity. These constructs were used as external or anchor-based measures to determine MCIDs for each sub-scale of the MFI. Multiple MCIDs were identified, each from a different perspective based on the constructs cited. Researchers seeking to use a generic MCID may wish to use a two-point reference for each MFI sub-scale as it was consistent across the pre- and post-radiotherapy comparison and occupational productivity anchors. MCIDs validated in this study allow better interpretation of changes in MFI sub-scale scores and allow effect size calculations for determining sample size in future studies.
Basic Values, Career Orientations, and Career Anchors: Empirical Investigation of Relationships
Abessolo, Marc; Rossier, Jérôme; Hirschi, Andreas
2017-01-01
In today's dynamic and uncertain career context, values play an important role for career choice and lifelong career self-management. Values are desirable goals that are sought by individuals to satisfy their needs and are important for understanding career orientations in terms of protean and boundaryless career orientations and career anchors. However, how career orientations or career anchors fit into a well-established and supported model and into the structure of basic human values remains an important and under-investigated question. The aim of this study was to use Schwartz's model of structural values to empirically explore the relationships and structural correspondences among basic values, career orientations, and career anchors. A heterogeneous sample of 238 employees from French-speaking Switzerland (Mage = 35.60, SD = 13.03) completed the Portrait Values Questionnaire (PVQ5X), the Protean and Boundaryless Career Attitudes Scales (PCAS, BCAS), and the Career Orientation Inventory (COI) via an anonymous and confidential survey questionnaire. The results showed that it was possible to meaningfully position both career orientations and career anchors in Schwartz's values structure. The protean and boundaryless career orientations were positively related to Schwartz's basic values that emphasized openness to change and career anchors meaningfully followed the motivational continuum of these basic values. Overall, the overlap among the basic values, career orientations, and career anchors appeared relatively important, suggesting that these basic values, orientations, and anchors should be considered simultaneously to understand and address the factors and processes underlying individuals' career choices and paths. PMID:28955275
Mayor, S; Maxfield, F R
1995-01-01
A diverse set of cell surface eukaryotic proteins including receptors, enzymes, and adhesion molecules have a glycosylphosphoinositol-lipid (GPI) modification at the carboxy-terminal end that serves as their sole means of membrane anchoring. These GPI-anchored proteins are poorly solubilized in nonionic detergent such as Triton X-100. In addition these detergent-insoluble complexes from plasma membranes are significantly enriched in several cytoplasmic proteins including nonreceptor-type tyrosine kinases and caveolin/VIP-21, a component of the striated coat of caveolae. These observations have suggested that the detergent-insoluble complexes represent purified caveolar membrane preparations. However, we have recently shown by immunofluorescence and electron microscopy that GPI-anchored proteins are diffusely distributed at the cell surface but may be enriched in caveolae only after cross-linking. Although caveolae occupy only a small fraction of the cell surface (< 4%), almost all of the GPI-anchored protein at the cell surface becomes incorporated into detergent-insoluble low-density complexes. In this paper we show that upon detergent treatment the GPI-anchored proteins are redistributed into a significantly more clustered distribution in the remaining membranous structures. These results show that GPI-anchored proteins are intrinsically detergent-insoluble in the milieu of the plasma membrane, and their co-purification with caveolin is not reflective of their native distribution. These results also indicate that the association of caveolae, GPI-anchored proteins, and signalling proteins must be critically re-examined. Images PMID:7579703
Task difficulty has no effect on haptic anchoring during tandem walking in young and older adults.
Costa, Andréia Abud da Silva; Santos, Luciana Oliveira Dos; Mauerberg-deCastro, Eliane; Moraes, Renato
2018-02-14
This study assessed the contribution of the "anchor system's" haptic information to balance control during walking at two levels of difficulty. Seventeen young adults and seventeen older adults performed 20 randomized trials of tandem walking in a straight line, on level ground and on a slightly-raised balance beam, both with and without the use of the anchors. The anchor consists of two flexible cables, whose ends participants hold in each hand, to which weights (125 g) are attached at the opposing ends, and which rest on the ground. As the participants walk, they pull on the cables, dragging the anchors. Spatiotemporal gait variables (step speed and single- and double-support duration) were processed using retro-reflective markers on anatomical sites. An accelerometer positioned in the cervical region registered trunk acceleration. Walking on the balance beam increased single- and double-support duration and reduced step speed in older adults, which suggests that this condition was more difficult than walking on the level ground. The anchors reduced trunk acceleration in the frontal plane, but the level of difficulty of the walking task showed no effect. Thus, varying the difficulty of the task had no influence on the way in which participants used the anchor system while tandem walking. The older adults exhibited more difficulty in walking on the balance beam as compared to the younger adults; however, the effect of the anchor system was similar in both groups. Copyright © 2017 Elsevier B.V. All rights reserved.
Basic Values, Career Orientations, and Career Anchors: Empirical Investigation of Relationships.
Abessolo, Marc; Rossier, Jérôme; Hirschi, Andreas
2017-01-01
In today's dynamic and uncertain career context, values play an important role for career choice and lifelong career self-management. Values are desirable goals that are sought by individuals to satisfy their needs and are important for understanding career orientations in terms of protean and boundaryless career orientations and career anchors. However, how career orientations or career anchors fit into a well-established and supported model and into the structure of basic human values remains an important and under-investigated question. The aim of this study was to use Schwartz's model of structural values to empirically explore the relationships and structural correspondences among basic values, career orientations, and career anchors. A heterogeneous sample of 238 employees from French-speaking Switzerland (Mage = 35.60, SD = 13.03) completed the Portrait Values Questionnaire (PVQ5X), the Protean and Boundaryless Career Attitudes Scales (PCAS, BCAS), and the Career Orientation Inventory (COI) via an anonymous and confidential survey questionnaire. The results showed that it was possible to meaningfully position both career orientations and career anchors in Schwartz's values structure. The protean and boundaryless career orientations were positively related to Schwartz's basic values that emphasized openness to change and career anchors meaningfully followed the motivational continuum of these basic values. Overall, the overlap among the basic values, career orientations, and career anchors appeared relatively important, suggesting that these basic values, orientations, and anchors should be considered simultaneously to understand and address the factors and processes underlying individuals' career choices and paths.
The Importance of Content Representation for Common-Item Equating with Nonrandom Groups.
ERIC Educational Resources Information Center
Klein, Lawrence W.; Jarjoura, David
1985-01-01
The test equating accuracy of content-representative anchors (subsets of items in common) versus nonrepresentative, but substantially longer, anchors was compared for a professional certification examination. Through a chain of equatings, it was found that content representation in anchors was critical. (Author/GDC)
NASA Technical Reports Server (NTRS)
Mashburn, D.; Wald, J. E.; Helmsin, F. K.
1982-01-01
Tiedown bracket secured to concrete slab with lag anchor and lag bolt. A trailer or other heavy equipment can be anchored by tethering it to strapping bolt. When bracket is no longer needed, it can be removed, leaving behind only lag anchor. Bracket is easily installed and removed without damage to concrete slab.
Anchors of Religious Commitment in Adolescents
ERIC Educational Resources Information Center
Layton, Emily; Dollahite, David C.; Hardy, Sam A.
2011-01-01
This study explores adolescent religious commitment using qualitative data from a religiously diverse (Jewish, Christian, Muslim) sample of 80 adolescents. A new construct, "anchors of religious commitment," grounded in interview data, is proposed to describe what adolescents commit to as a part of their religious identity. Seven anchors of…
How to Anchor Machinery in Your School Shop
ERIC Educational Resources Information Center
Walker, John R.
1978-01-01
An industrial arts teacher explains the need to mount school shop machinery securely and describes methods of mounting permanently or temporarily. Reasons for anchoring machine tools are safety, accuracy of operation, and the prevention of damage to the machine. Five figures illustrate anchoring and leveling. (MF)
Cytoplasmic motion induced by cytoskeleton stretching and its effect on cell mechanics.
Zhang, T
2011-09-01
Cytoplasmic motion assumed as a steady state laminar flow induced by cytoskeleton stretching in a cell is determined and its effect on the mechanical behavior of the cell under externally applied forces is demonstrated. Non-Newtonian fluid is assumed for the multiphase cytoplasmic fluid and the analytical velocity field around the macromolecular chain is obtained by solving the reduced nonlinear momentum equation using homotopy technique. The entropy generation by the fluid internal friction is calculated and incorporated into the entropic elasticity based 8-chain constitutive relations. Numerical examples showed strengthening behavior of cells in response to externally applied mechanical stimuli. The spatial distribution of the stresses within a cell under externally applied fluid flow forces were also studied.
Markolf, Keith L; Jackson, Steven; McAllister, David R
2012-09-01
Syndesmosis (high ankle) sprains produce disruption of the distal tibiofibular ligaments. Forces on the distal fibula that produce these injuries are unknown. Twenty-seven fresh-frozen lower extremities were used for this study. A load cell recorded forces acting on the distal fibula from forced ankle dorsiflexion and applied external foot torque; medial-lateral and anterior-posterior displacements of the distal fibula were recorded. Fibular forces and axial displacements were also recorded with applied axial force. During forced ankle dorsiflexion and external foot torque tests, the distal fibula always displaced posteriorly with respect to the tibia with no measurable medial-lateral displacement. With 10 Nm dorsiflexion moment, cutting the tibiofibular ligaments approximately doubled fibular force and displacement values. Cutting the tibiofibular ligaments significantly increased fibular displacement from applied external foot torque. Fibular forces and axial displacements from applied axial weight-bearing force were highest with the foot dorsiflexed. The highest mean fibular force in the study (271.9 N) occurred with 10 Nm external foot torque applied to a dorsiflexed foot under 1000 N axial force. Two important modes of loading that could produce high ankle sprains were identified: forced ankle dorsiflexion and external foot torque applied to a dorsiflexed ankle loaded with axial force. The distal tibiofibular ligaments restrained fibular displacement during these tests. Residual mortise widening observed at surgery may be the result of tibiofibular ligament injuries caused by posterior displacement of the fibula. Therefore, a syndesmosis screw used to fix the fibula would be subjected to posterior bending forces from these loading modes. Ankle bracing to prevent extreme ankle dorsiflexion during rehabilitation may be advisable to prevent excessive fibular motions that could affect syndesmosis healing.
Advancing the vesosome, a multifunctional drug delivery platform, toward applied in vivo testing
NASA Astrophysics Data System (ADS)
Wong, Benjamin J.
An optimal drug delivery vehicle should circulate long enough to reach the site of illness or disease, possess a large drug loading capacity, retain its contents over the course of treatment, and be able deliver its contents at a rate appropriate for maximum therapeutic benefit at the site of interest. The vesosome, a large lipid bilayer enclosing multiple, smaller liposomes, is our solution to addressing these needs. The external lipid bilayer offers a second barrier of protection for interior components and can also serve as the anchor for active targeting components. Furthermore, internal compartmentalization permits customization of separate environments for multiple therapeutics and release triggers. Previous work established the ability of the vesosome to retain its contents in vitro an order of magnitude longer than liposomes. To be viable in vivo, the vesosome must be functionalized for biocompatibility and tracking, and its synthetic procedure must be repeatable, reliable and result in a purified product. The vesosome was functionalized by introducing biocompatible polymers, such as poly(ethylene glycol) (PEG), and fluorescent dyes in their lipid-bound forms into the external membrane of the vesosome. The external vesosomal membrane is formed from large, flat lipid sheets in the interdigitated (L betaI) phase which, when heated, are used to encapsulate smaller drug-containing vesicles. Through X-Ray diffraction (XRD) and freeze-fracture transmission electron microscopy (FF-TEM), we established that the molar amounts of functionalized lipid required to label the vesosome for tracking and biocompatibility (˜5--7mol% total) did not prevent the formation of the interdigitated phase. Thus, functionalization of the external vesosome membrane can be achieved through functionalization of interdigitated sheets. For in vivo testing, functionalized vesosomes must be separated from unencapsulated vesicles and purification was performed using size exclusion chromatography (SEC) and centrifugation. Having functionalized vesosomes for biocompatibility, PEGylated vesosomes were examined in vitro and in vivo. The presence of surface-grafted PEG was shown to reduce vesosome-vesosome aggregation when exposed to human blood and the circulation half-life was determined to be approximately 2 hours. The evolution of biodistribution was examined by functionalizing the vesosome with a near-infrared dye for in vivo fluorescence imaging and preliminary active targeting experiments show increased vesosome presence at the targeted sites. Ex vivo organ analysis showed the ability of the vesosome to maintain structural integrity for at least 24 hours post-injection. By functionalizing the vesosome for biocompatibility and tracking through a repeatable and reliable synthesis, we have obtained a biocompatible vesosome. Through proof-of-concept live animal testing, we have demonstrated the feasibility of the vesosome as a single site, single dose, multi-therapeutic drug delivery vehicle.
1976-12-01
ik’sigi. of undcruater cattle arrays wt’uld opertioal onsraitsbe the primari goali Arr. consitruction technolog% deseclopmcnt %%A% a %ccont!aro goal...weight of 12,500 pounds. struction mooring anchor was pulled out while load The anchor is composed of a 7-foot by 8-foot by and displacement were...out of the bottom. In contrast, anchor AI pulled out to 27,000 pounds for the construction moor anchor. at a load of 3,500 pounds although a 10,000
2014-05-21
UTC REQUIRES PERSONNEL FROM STANDARD PRIME BEEF OR RED 4F9K4 PROVIDES FOLDED FIBERGLASS MATTING ( FFM ) FOR AIRFIELD DAMAGE REPAIR (ADR). PACKAGE...CONSISTS OF THREE FFM SETS (54’ X 60’), ONE FFM SUPPORT TOOL KIT, UPPER BUSHINGS, ANCHOR BUSHINGS, ANCHOR BOLTS, AND TWO EA MC-7 AIR COMPRESSORS. EACH...PACKAGE CONSISTS OF 7 FOLDED FIBERGLASS MAT SETS (54 FT X 60 FT), 2 FFM SUPPORT TOOL KIT, UPPER BUSHINGS, ANCHOR BUSHINGS, ANCHOR BOLTS AND 4 X
Autonomous Landing and Smart Anchoring for In-Situ Exploration of Small Bodies
NASA Technical Reports Server (NTRS)
Ghavimi, Ali R.; Serricchio, Frederick; Hadaegh, Fred Y.; Dolgin, Ben
2000-01-01
Future NASA missions include in-situ scientific explorations of small interplanetary objects like comets and asteroids. Sample acquisition systems are envisioned to operate directly from the landers that are anchored to the surface. Landing and anchoring proves to be challenging in the absence of an attitude control system and in the presence of nearly zero-gravity environments with uncertain surface terrain and unknown mechanical properties. This paper presents recent advancements in developing a novel landing and anchoring control system for the exploration of small bodies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, MooHyun
2014-08-01
This report presents the development of offshore anchor data sets which are intended to be used to develop a database that allows preliminary selection and sizing of anchors for the conceptual design of floating offshore wind turbines (FOWTs). The study is part of a project entitled “Development of Mooring-Anchor Program in Public Domain for Coupling with Floater Program for FOWTs (Floating Offshore Wind Turbines)”, under the direction of Dr. Moo-Hyun Kim at the Texas A&M University and with the sponsorship from the US Department of Energy (Contract No. DE-EE0005479, CFDA # 81.087 for DE-FOA-0000415, Topic Area 1.3: Subsurface Mooring andmore » Anchoring Dynamics Models).« less
Two novel self-assemblies of supramolecular solar cells using N-heterocyclic-anchoring porphyrins.
Zhang, Qian; Wu, Fang-Yuan; Liu, Jia-Cheng; Li, Ren-Zhi; Jin, Neng-Zhi
2018-02-15
Two novel N-substituted anchoring porphyrins (ZnPAtz and ZnPAim) have been devised and synthesized. Moreover, these two anchoring porphyrins were linked to the TiO 2 semiconductor through carboxyl groups and then a zinc porphyrin ZnP was bound to the anchoring porphyrin using a zinc-to-ligand axial coordination approach. The different performances of these assemblies were compared with single anchoring porphyrin devices ZnPAtz and ZnPAim. The photoelectric conversion efficiency of the new supramolecular solar cells sensitized by ZnP-ZnPAx (x=tz, im) has been improved. The ZnP-ZnPAtz-based DSSCs provided the highest photovoltaic efficiency (1.86%). Fundamental studies showed that incorporation of these assemblies promote light-harvesting efficiency. Copyright © 2017. Published by Elsevier B.V.
Poor anchoring limits dyslexics' perceptual, memory, and reading skills.
Oganian, Yulia; Ahissar, Merav
2012-07-01
The basic deficits underlying the severe and persistent reading difficulties in dyslexia are still highly debated. One of the major topics of debate is whether these deficits are language specific, or affect both verbal and non-verbal stimuli. Recently, Ahissar and colleagues proposed the "anchoring-deficit hypothesis" (Ahissar, Lubin, Putter-Katz, & Banai, 2006), which suggests that dyslexics have a general difficulty in automatic extraction of stimulus regularities from auditory inputs. This hypothesis explained a broad range of dyslexics' verbal and non-verbal difficulties. However, it was not directly tested in the context of reading and verbal memory, which poses the main stumbling blocks to dyslexics. Here we assessed the abilities of adult dyslexics to efficiently benefit from ("anchor to") regularities embedded in repeated tones, orally presented syllables, and written words. We also compared dyslexics' performance to that of individuals with attention disorder (ADHD), but no reading disability. We found an anchoring effect in all groups: all gained from stimulus repetition. However, in line with the anchoring-deficit hypothesis, controls and ADHD participants showed a significantly larger anchoring effect in all tasks. This study is the first that directly shows that the same domain-general deficit, poor anchoring, characterizes dyslexics' performance in perceptual, working memory and reading tasks. Copyright © 2012 Elsevier Ltd. All rights reserved.
Comparison between suture anchor and transosseous suture for the modified-Broström procedure.
Cho, Byung-Ki; Kim, Yong-Min; Kim, Dong-Soo; Choi, Eui-Sung; Shon, Hyun-Chul; Park, Kyoung-Jin
2012-06-01
This prospective, randomized study was conducted to compare clinical outcomes of the modified Broström procedure using suture anchor or transosseous suture technique for chronic ankle instability. Forty patients were followed for more than 2 years after modified Broström procedure. Twenty procedures using a suture anchor and 20 procedures using a transosseous suture were performed by one surgeon. The clinical evaluation consisted of the Karlsson scale and the Sefton grading system. Talar tilt and anterior talar translation were measured on anterior and varus stress radiographs. The Karlsson scale had improved significantly to 90.8 points in the suture anchor group, and to 89.2 points in the transosseous suture group. According to Sefton grading system, 18 patients (90%) in suture anchor group and 17 patients (85%) in transosseous suture group achieved satisfactory results. The talar tilt angle and anterior talar translation improved significantly to 5.9 degrees and 4.2 mm in suture anchor group, and to 5.4 degrees and 4.1 mm in transosseous suture group, respectively. No significant differences existed in clinical and functional outcomes between the two techniques for ligament reattachment. Both modified Broström procedures using the suture anchor and transosseous suture seem to be effective treatment methods for chronic lateral ankle instability.
Role of space charges on light-induced effects in nematic liquid crystals doped by methyl red.
Lucchetti, L; Simoni, F
2014-03-01
We show that both the extraordinarily large nonlinear response and the light-induced permanent reorientation in liquid crystals doped by the azo dye methyl red originates from the same phenomenon of modification of the charge density on the irradiated surface. The demonstration is done by applying ac voltage to the samples, showing that in this case no permanent anchoring is possible. The measurements confirm the role of photoisomerization that gives a transient contribution to the actual reorientation process only in the high dose regime. This result allows us to draw a picture for light-induced effects that might be applied to a large class of compounds.
Osseous adaptation to continuous loading of rigid endosseous implants
NASA Technical Reports Server (NTRS)
Roberts, W. E.; Smith, R. K.; Mozsary, P. G.; Zilberman, Y.; Smith, R. S.
1984-01-01
The effect of loading on etched Ti implants in the femurs of young (3 mo) and adult (6 mo) rabbits is investigated experimentally. The results are presented in photographs, fluorescence and polarization micrographs, radiographs, and drawings and discussed. Implantation is followed by formation of coarse woven bone within 3 d and mature lamellar bone by 6 wks, with nonspecific subperiosteal bony hypertrophy in the young rabbits only. Spring loading at 100 g produces spontaneous spiral-type fractures when applied immediately, but the implants remain rigid when loads are applied after 6-12 wks of healing. The mechanisms of bone formation involved are examined, and the potential of endosseous implants as anchors in orthodontics or dentofacial-orthopedics is confirmed.
Immersed Boundary Simulations of Active Fluid Droplets
Hawkins, Rhoda J.
2016-01-01
We present numerical simulations of active fluid droplets immersed in an external fluid in 2-dimensions using an Immersed Boundary method to simulate the fluid droplet interface as a Lagrangian mesh. We present results from two example systems, firstly an active isotropic fluid boundary consisting of particles that can bind and unbind from the interface and generate surface tension gradients through active contractility. Secondly, a droplet filled with an active polar fluid with homeotropic anchoring at the droplet interface. These two systems demonstrate spontaneous symmetry breaking and steady state dynamics resembling cell motility and division and show complex feedback mechanisms with minimal degrees of freedom. The simulations outlined here will be useful for quantifying the wide range of dynamics observable in these active systems and modelling the effects of confinement in a consistent and adaptable way. PMID:27606609
Lehmann, D M
1998-05-01
The performance of an organization is paced by its use of resources, including its ability to acquire, access, and use knowledge. A high-performance organization, more than likely, has structured its resources around process linkages and is characterized by a horizontal organization chart, teams and teamwork, empowerment, and operational excellence. Organizational researchers hypothesize that performance improves with fuzzy internal boundaries, cross-functional participation, and goals anchored in the interests of customers and other external stakeholders. This article looks at the competitive need for more integration of resources and greater sharing of knowledge, the integrated nature of work within emerging types of organizations, how expanded views can improve the marketplace centering of processes and individuals, and how combining a model of integration and individual work challenges thinking and actions in the new environment.
Fiske, Alan Page
2002-01-01
Analyzing national and ethnic differences in individualism and collectivism, D. Oyserman, H. M. Coon, and M. Kemmelmeier (2002) showed that small differences in scales or samples produce markedly divergent results, challenging the validity of these constructs. The author examines the following limitations of research on individualism and collectivism: It treats nations as cultures and culture as a continuous quantitative variable; conflates all kinds of social relations and distinct types of autonomy; ignores contextual specificity in norms and values; measures culture as the personal preferences and behavior reports of individuals; rarely establishes the external validity of the measures used; assumes cultural invariance in the meaning of self-reports and anchoring and interpretation of scales; and reduces culture to explicit, abstract verbal knowledge.
Assessing tether anchor labeling and usability in pickup trucks.
Klinich, Kathleen D; Manary, Miriam A; Malik, Laura A; Flannagan, Carol A; Jermakian, Jessica S
2018-04-03
The objective of this study was to investigate vehicle factors associated with child restraint tether use and misuse in pickup trucks and evaluate 4 labeling interventions designed to educate consumers on proper tether use. Volunteer testing was performed with 24 subjects and 4 different pickup trucks. Each subject performed 8 child restraint installations among the 4 pickups using 2 forward-facing restraints: a Britax Marathon G4.1 and an Evenflo Triumph. Vehicles were selected to represent 4 different implementations of tether anchors among pickups: plastic loop routers (Chevrolet Silverado), webbing routers (Ram), back wall anchors (Nissan Frontier), and webbing routers plus metal anchors (Toyota Tundra). Interventions included a diagram label, Quick Response (QR) Code linked to video instruction, coordinating text label, and contrasting text tag. Subjects used the child restraint tether in 93% of trials. However, tether use was completely correct in only 9% of trials. An installation was considered functional if the subject attached the tether to a tether anchor and had a tight installation (ignoring routing and head restraint position); 28% of subjects achieved a functional installation. The most common installation error was attaching the tether hook to the anchor/router directly behind the child restraint (near the top of the seatback) rather than placing the tether through the router and attaching it to the anchor in the adjacent seating position. The Nissan Frontier, with the anchor located on the back wall of the cab, had the highest rate of correct installations but also had the highest rate of attaching the tether to components other than the tether anchor (seat adjustor, child restraint storage hook, around head restraint). None of the labeling interventions had a significant effect on correct installation; not a single subject scanned the QR Code to access the video instruction. Subjects with the most successful installations spent extensive time reviewing the vehicle manuals. Current implementations of tether anchors among pickup trucks are not intuitive for child restraint installations, and alternate designs should be explored. Several different labeling interventions were ineffective at achieving correct tether use in pickup trucks.
Rodríguez-González, Abril; Míguez-Lozano, Raúl; Llopis-Belenguer, Cristina; Balbuena, Juan Antonio
2015-04-01
Evaluating phenotypic plasticity in attachment organs of parasites can provide information on the capacity to colonise new hosts and illuminate evolutionary processes driving host specificity. We analysed the variability in shape and size of the dorsal and ventral anchors of Ligophorus cephali from Mugil cephalus by means of geometric morphometrics and multivariate statistics. We also assessed the morphological integration between anchors and between the roots and points in order to gain insight into their functional morphology. Dorsal and ventral anchors showed a similar gradient of overall shape variation, but the amount of localised changes was much higher in the former. Statistical models describing variations in shape and size revealed clear differences between anchors. The dorsal anchor/bar complex seems more mobile than the ventral one in Ligophorus, and these differences may reflect different functional roles in attachment to the gills. The lower residual variation associated with the ventral anchor models suggests a tighter control of their shape and size, perhaps because these anchors seem to be responsible for firmer attachment and their size and shape would allow more effective responses to characteristics of the microenvironment within the individual host. Despite these putative functional differences, the high level of morphological integration indicates a concerted action between anchors. In addition, we found a slight, although significant, morphological integration between roots and points in both anchors, which suggests that a large fraction of the observed phenotypic variation does not compromise the functional role of anchors as levers. Given the low level of genetic variation in our sample, it is likely that much of the morphological variation reflects host-driven plastic responses. This supports the hypothesis of monogenean specificity through host-switching and rapid speciation. The present study demonstrates the potential of geometric morphometrics to provide new and previously unexplored insights into the functional morphology of attachment and evolutionary processes of host-parasite coevolution. Copyright © 2015 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.
Mattei, Tobias A; Teles, Alisson R; Dinh, Dzung H
2016-01-05
Zero-profile (also called self-locking, anchored or stand-alone cages) have been recently proposed as an interesting alternative for anterior cervical discectomy and fusion (ACDF), as they are supposed to reduce the rates of post-operative cage extrusion without necessarily incurring in the additional surgical time and increased rates of dysphagia associated with plating. Nevertheless, the exact indications of zero-profile anchored cages have not yet been established in the literature. To report the first case of a vertebral body fracture between the blades of zero-profile anchored cages after ACDFs in adjacent levels and to review the available literature on hardware-related complications after multi-level ACDFs with zero-profile anchored cages. Case report and systematic literature review. The authors report the first case of a vertebral body fracture between the blades of zero-profile anchored cages after ACDFs in adjacent levels. The patient presented with refractory mechanical neck pain at the 1-month post-operative follow-up, ultimately requiring a posterior instrumented fusion. A comprehensive systematic literature review on the available data regarding the safety, complications as well as radiological and clinical outcomes of zero-profile anchored cages is also performed. In the reported case, the use of zero-profile anchored cages in adjacent levels on the cervical spine led to a fracture of the vertebral body between the cages at the 1-month follow-up, with anterior avulsion of the part of the vertebral body where the blades from the two cages converged. According to the systematic literature review which included 409 patients from 10 different clinical series (with a total cumulative follow-up of approximately 535 patients-year), there were only two reported hardware-related complications after ACDF with zero-profile anchored cages, none of them involving fracture at the level of convergence of blades or screws. Although hardware-related complications after the use of zero-profile anchored cages seem to be rare events, future biomechanical and clinical studies are warranted in order to evaluate the safety of employing such devices for the treatment of multilevel degenerative disc disease in the cervical spine.
21 CFR 868.5935 - External negative pressure ventilator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ventilator. (a) Identification. An external negative pressure ventilator (e.g., iron lung, cuirass) is a device chamber that is intended to support a patient's ventilation by alternately applying and releasing external negative pressure over the diaphragm and upper trunk of the patient. (b) Classification. Class II...
Bhardwaj, Ankur; Grobler, Anne; Rath, Goutam; Goyal, Amit Kumar; Jain, Amit Kumar; Mehta, Abhinav
2016-01-01
Mycobacterium tuberculosis (M. TB) remains the prime cause of bacterial mortality and morbidity world-wide. Therefore, effective delivery and targeting of drug to the cellular tropics is essentially required to generate significant results for tuberculosis treatment. The aim of the present study was to develop and characterize ligand anchored pH sensitive liposomes (TPSL) as dry powder inhaler for the targeted delivery of drugs in the target site i.e. lungs. Ligand anchored PSL (TPSL) was prepared by thin film hydration for the combined delivery of Isoniazid (INH) and Ciprofloxacin HCl (CIP HCl) using 4-aminophenyl-α-D mannopyranoside (Man) as surface functionalized ligand and characterized using different parameters. It was observed that size of the ligand anchored liposomes (TPSL) was slightly more than the non-ligand anchored liposomes (PSL). Drug release was studied at different pH for 24 hrs and it was observed that liposomes exhibited slow release at alkaline pH (58-64%) as compared to macrophage pH (81-87%) where it increased dramatically due to the destabilization of pH sensitive liposome (PSL). In vitro cellular uptake study showed that much higher concentration was achieved in the alveolar macrophage using ligand anchored liposomes as compared to its counterpart. In vivo study showed that maximum drug accumulation was achieved in the lung by delivering drug using ligand anchored PSL as compared to conventional PSL. It was concluded that ligand anchored pH sensitive liposome is one of the promising systems for the targeted drug therapy in pulmonary tuberculosis.
Pantoja, Joe Luis; Ge, Liang; Zhang, Zhihong; Morrel, William G; Guccione, Julius M; Grossi, Eugene A; Ratcliffe, Mark B
2014-10-01
The role of posterior papillary muscle anchoring (PPMA) in the management of chronic ischemic mitral regurgitation (CIMR) is controversial. We studied the effect of anchoring point direction and relocation displacement on left ventricular (LV) regional myofiber stress and pump function. Previously described finite element models of sheep 16 weeks after posterolateral myocardial infarction (MI) were used. True-sized mitral annuloplasty (MA) ring insertion plus different PPM anchoring techniques were simulated. Anchoring points tested included both commissures and the central anterior mitral annulus; relocation displacement varied from 10% to 40% of baseline diastolic distance from the PPM to the anchor points on the annulus. For each reconstruction scenario, myofiber stress in the MI, border zone, and remote myocardium as well as pump function were calculated. PPMA caused reductions in myofiber stress at end-diastole and end-systole in all regions of the left ventricle that were proportional to the relocation displacement. Although stress reduction was greatest in the MI region, it also occurred in the remote region. The maximum 40% displacement caused a slight reduction in LV pump function. However, with the correction of regurgitation by MA plus PPMA, there was an overall increase in forward stroke volume. Finally, anchoring point direction had no effect on myofiber stress or pump function. PPMA reduces remote myofiber stress, which is proportional to the absolute distance of relocation and independent of anchoring point. Aggressive use of PPMA techniques to reduce remote myofiber stress may accelerate reverse LV remodeling without impairing LV function. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Bruneau, J M; Magnin, T; Tagat, E; Legrand, R; Bernard, M; Diaquin, M; Fudali, C; Latgé, J P
2001-08-01
Previous studies in Aspergillus fumigatus (Mouyna I., Fontaine T., Vai M., Monod M., Fonzi W. A., Diaquin M., Popolo L., Hartland R. P., Latgé J.-P, J. Biol. Chem. 2000, 275, 14882-14889) have shown that a glucanosyltransferase playing an important role in fungal cell wall biosynthesis is glycosylphosphatidylinositol (GPI) anchored to the membrane. To identify other GPI-anchored proteins putatively involved in cell wall biogenesis, a proteomic analysis has been undertaken in A. fumigatus and the protein data were matched with the yeast genomic data. GPI-anchored proteins of A. fumigatus were released from membrane preparation by an endogenous GPI-phospholipase C, purified by liquid chromatography and separated by two-dimensional electrophoresis. They were characterized by their peptide mass fingerprint through matrix-assisted laser desorption/ionization-time of flight-(MALDI-TOF)-mass spectrometry and by internal amino acid sequencing. Nine GPI-anchored proteins were identified in A. fumigatus. Five of them were homologs of putatively GPI-anchored yeast proteins (Csa1p, Crh1p, Crh2p, Ecm33p, Gas1p) of unknown function but shown by gene disruption analysis to play a role in cell wall morphogenesis. In addition, a comparative study performed with chitin synthase and glucanosyl transferase mutants of A. fumigatus showed that a modification of the growth phenotype seen in these mutants was associated to an alteration of the pattern of GPI-anchored proteins. These results suggest that GPI-anchored proteins identified in this study are involved in A. fumigatus cell wall organization.
Engineering report for simulated riser installation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brevick, C.H., Westinghouse Hanford
1996-05-09
The simulated riser installation field tests demonstrated that new access ports (risers) can be installed safely, quickly, and economically in the concrete domes of existing underground single- shell waste storage tanks by utilizing proven rotary drilling equipment and vacuum excavation techniques. The new riser installation will seal against water intrusion, provide as table riser anchored to the tank dome, and be installed in accordance with ALARA principles. The information contained in the report will apply to actual riser installation activity in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, Rishi, E-mail: kkraina@gmail.com; Sood, Srishti, E-mail: kkraina@gmail.com; Raina, K. K., E-mail: kkraina@gmail.com
2014-04-24
We have developed azo dye doped nematic liquid crystal complex for advanced photonic liquid crystal display technology aspects. Disperse orange azo dye self introduced planer alignment in the nematic liquid crystal without any surface anchoring treatment. Planer alignment was characterized by optical polarizing microscopy. The electro-optical switching response of dye disperse planer aligned nematic cell was investigated as a function of applied voltage with the help of photoluminescence spectrophotometer for the tuning of photoluminescence contrast.
Ponterotto, Joseph G; Ruckdeschel, Daniel E
2007-12-01
The present article addresses issues in reliability assessment that are often neglected in psychological research such as acceptable levels of internal consistency for research purposes, factors affecting the magnitude of coefficient alpha (alpha), and considerations for interpreting alpha within the research context. A new reliability matrix anchored in classical test theory is introduced to help researchers judge adequacy of internal consistency coefficients with research measures. Guidelines and cautions in applying the matrix are provided.
NASA Astrophysics Data System (ADS)
Kikuchi, Yusuke; Yoshikawa, Tatsuya; Nishioka, Tsutomu; Hashimoto, Shotaro; Fukumoto, Naoyuki; Nagata, Masayoshi
Application of an externally applied rotating magnetic field (RMF) for control of MHD relaxation phenomena driven by a coaxial helicity injection has been proposed in the HIST spherical torus device. In this letter, the plasma responses to the RMF evaluated by magnetic fields inside the plasma in HIST are shown.
DOT National Transportation Integrated Search
2017-03-01
The objective of the study was to demonstrate the feasibility of using bi-directional layouts of CFRP for shear : strengthening of bridge girders. In a previous project (0-6306), it was demonstrated that uni-directional CFRP : strips and CFRP anchors...
ERIC Educational Resources Information Center
Lin, Shu-Yuan; Xie, Ying
2017-01-01
Group discussions are critical for students constructing new understanding and knowledge in both classroom and distance education. Tagclouds can provide an intuitive overview about the group's collective knowledge and could potentially be used as an anchor for group discussions. The effect of using tagclouds as anchors for group discussions was…
Approaches to Interactive Video Anchors in Problem-Based Science Learning
ERIC Educational Resources Information Center
Kumar, David Devraj
2010-01-01
This paper is an invited adaptation of the IEEE Education Society Distinguished Lecture Approaches to Interactive Video Anchors in Problem-Based Science Learning. Interactive video anchors have a cognitive theory base, and they help to enlarge the context of learning with information-rich real-world situations. Carefully selected movie clips and…
107. View showing open caisson Pier 4 with anchor bolts ...
107. View showing open caisson Pier 4 with anchor bolts placed ready for last pour of concrete. Also pile driver driving falsework piles for south anchor arm. Located at end of the old ferry landing slip at Crockett side of straits. - Carquinez Bridge, Spanning Carquinez Strait at Interstate 80, Vallejo, Solano County, CA
Choice of Anchor Test in Equating. Research Report. ETS RR-06-35
ERIC Educational Resources Information Center
Sinharay, Sandip; Holland, Paul
2006-01-01
It is a widely held belief that anchor tests should be miniature versions (i.e., minitests), with respect to content and statistical characteristics of the tests being equated. This paper examines the foundations for this belief. It examines the requirement of statistical representativeness of anchor tests that are content representative. The…
75 FR 37876 - Buy America Waiver Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-30
... hollow core threaded share anchor rods in construction of Federal-aid project X-STP-1525 (004) in Oregon... is appropriate for the use of non- domestic 1'' diameter hollow core threaded share anchor rods for... to issue a waiver for the 1'' diameter hollow core threaded share anchor rods ( http://www.fhwa.dot...
Understanding Rasch Measurement: Partial Credit Model and Pivot Anchoring.
ERIC Educational Resources Information Center
Bode, Rita K.
2001-01-01
Describes the Rasch measurement partial credit model, what it is, how it differs from other Rasch models, and when and how to use it. Also describes the calibration of instruments with increasingly complex items. Explains pivot anchoring and illustrates its use and describes the effect of pivot anchoring on step calibrations, item hierarchy, and…
Cholesteric pitch transitions induced by mechanical strain.
Lelidis, I; Barbero, G; Alexe-Ionescu, A L
2013-02-01
We investigate thickness and surface anchoring strength influence on pitch transitions in a planar cholesteric liquid crystal layer. The cholesteric-nematic transition is also investigated. We assume planar boundary conditions, with strong anchoring strength at one interface and weak anchoring strength at the other. The surface anchoring energy we consider to describe the deviation of the surface twist angle from the easy axis induced by a bulk deformation is a parabolic potential or Rapini and Papoular periodic potential, respectively. We show that under strain, all pitch transitions take place at a critical thickness that is equal to the quarter of the natural cholesteric pitch. The latter result does not depend on the anchoring strength, the particular surface potential, or material properties. The twist angle on the limiting surface characterized by weak anchoring varies with strain either by slipping and or in a discontinuous manner according to the thickness of the sample. The position of the bifurcation point depends only on the ratio of the extrapolation length over the layer thickness, but its value is model dependent. Multistability and multiplicity of the transition are discussed.
NASA Astrophysics Data System (ADS)
Chen, Wenzhao; Cui, Wenping
2018-03-01
The SMW method has many advantages, such as little influence on the surrounding environment, good watertight performance, wide range of application, short construction period, low cost and so on. In this paper, we chose the SMW engineering method combined with anchor cable to support structure in the second phase deep foundation pit of Jinan LuJinDongCheng as the research object, monitored and analysed the horizontal displacement of the pile top, Peripheral surface subsidence and internal force of the anchor cable in the foundation pit. We also discussed the displacement, internal force of anchor cable and the settlement of surrounding environment in the excavation of foundation pit and in different stages of construction. Conclusion:(1)The maximum horizontal displacement of the retaining structure is closely related to the depth and time of excavation, the construction of anchor cable can well limit the deformation of pile body; (2)Groundwater seepage caused by foundation pit dewatering will change the effective stress of soil. The change of groundwater level has an important influence on the working behavior of smw anchor cable supporting structure.
TWO-LAYER MODEL FOR PULL-OUT BEHAVIOR OF POST-INSTALLED ANCHOR
NASA Astrophysics Data System (ADS)
Saleem, Muhammad; Tsubaki, Tatsuya
A new two-layer anchor-infill assembly structure for the post-installed anchor is introduced with the analytical model to simulate its pull-out deformational response. The post-installed anchor is such that used in strengthening techniques for reinforced concrete structures. The properties of the infill material used for post-installed anchor are characterized by nonlinear interfaces. Because of the mechanical properties of the infill layer the existing pull-out model of deformed bars is not applicable in this case. Interfacial de-bonding is examined using energy criterion and strength criterion. The effect of the interface properties such as stiffness and strength on the pull-out behavior of a post-installed anchor is investigated. Using sensitivity analysis, the effect of these parameters on load-displacement curve, shear stress distribution, de-bonded length and damage to the surrounding concrete is clarified. Then, the optimum combination of these parameters is presented. It is confirmed that the elastic modulus of infill should be large to reduce the pull-out displacement and the increase of the shear strength of infill makes the pull-out load larger.
Forrester, Graham E; Flynn, Rebecca L; Forrester, Linda M; Jarecki, Lianna L
2015-01-01
Isolating the relative effects of episodic disturbances and chronic stressors on long-term community change is challenging. We assessed the impact of an episodic disturbance associated with human visitation (boat anchoring) relative to other drivers of long-term change on coral reefs. A one-time anchoring event at Crab Cove, British Virgin Islands, in 2004 caused rapid losses of coral and reef structural complexity that were equal to the cumulative decline over 23 years observed at an adjacent site. The abundance of small site-attached reef fishes dropped by approximately one quarter after the anchoring event, but this drop was not immediate and only fully apparent two years after the anchoring event. There was no obvious recovery from the impact, and no evidence that this episodic impact accelerated or retarded subsequent declines from other causes. This apparent lack of synergism between the effect of this episodic human impact and other chronic stressors is consistent with the few other long-term studies of episodic impacts, and suggests that action to mitigate anchor damage should yield predictable benefits.
Swigris, Jeffrey J.; Han, Meilan; Vij, Rekha; Noth, Imre; Eisenstein, Eric L.; Anstrom, Kevin J.; Brown, Kevin K.; Fairclough, Diane
2012-01-01
Background Idiopathic pulmonary fibrosis (IPF) is a progressive interstitial lung disease that often causes disabling dyspnea. In IPF and other lung diseases, patient-reported outcomes (PROs)—questionnaires designed to gather information from the patient's perspective—can determine whether therapies affect dyspnea or other outcomes meaningful to patients. Before a PRO can be used confidently as an outcome measure in a longitudinal trial, studies must demonstrate the PRO's ability to capture change over time in the target population. Our goal in this study was to examine whether the UCSD Shortness of Breath Questionnaire does so in patients with IPF. Methods We used data from the Sildenafil Trial of Exercise Performance in Idiopathic Pulmonary Fibrosis (STEP-IPF) to perform analyses that examined associations between UCSD scores and five external measures (anchors) at baseline and over time. Anchors included the Activity domain from St. George's Respiratory Questionnaire (SGRQ-A), the Physical Functioning domain from the SF-36 (SF36-PF), forced vital capacity (FVC), diffusing capacity of the lung for carbon monoxide (DLCO), and distance walked during a timed walk test (6MWD). Linear regression models were used to examine relationships between UCSD scores and anchors over time. Results At baseline, UCSD scores were weakly correlated with percent predicted FVC (−0.21, p=0.005) and percent predicted DLCO (−0.20, p=0.008), moderately correlated with 6MWD (−0.39, p<0.0001) and strongly correlated with SGRQ-A (0.79, p<0.0001) and SF36-PF (−0.72, p<0.0001). Change over time in UCSD scores was associated with change in FVC (estimate=2.54, standard error [SE]=1.23, p=0.04), SGRQ-A (estimate=7.94, SE=1.11, p<0.0001), SF36-PF (estimate=6.00, SE=1.13, p<0.0001), and 6MWD (estimate=4.23, SE=1.18, p=0.0004) but not DLCO (estimate=0.33, SE=1.33, p=0.80). Conclusions These results support the validity of the UCSD to assess change in dyspnea over time in patients with IPF. PMID:22801586
Sadness and susceptibility to judgmental bias: the case of anchoring.
Bodenhausen, G V; Gabriel, S; Lineberger, M
2000-07-01
In a wide range of empirical paradigms, sadness has been associated with more extensive and detail-oriented thinking than happiness, resulting in reductions in judgmental bias that arise from reliance on stereotypes and other simple decision heuristics. It was hypothesized that anchoring would constitute a significant exception to this general pattern. Recent research on anchoring indicates that an active thought process underlies the emergence of this bias. If sad people are likely to think more actively about the judgmental anchor than their neutral-mood counterparts, their subsequent judgments should be more likely to be assimilated toward this reference point. This prediction was confirmed in two experiments demonstrating that sad people are indeed more susceptible to anchoring bias than are people in a neutral mood. Moreover, this effect generalized over judgments in positive, neutral, and negative content domains.
Martin, Charles E; Fontaine, Lucien; Gardner, William H
2014-01-21
An electrochemical cell includes components that are welded from an external source after the components are assembled in a cell canister. The cell canister houses electrode tabs and a core insert. An end cap insert is disposed opposite the core insert. An external weld source, such as a laser beam, is applied to the end cap insert, such that the end cap insert, the electrode tabs, and the core insert are electrically coupled by a weld which extends from the end cap insert to the core insert.
Cachia, Victor V; Culbert, Brad; Warren, Chris; Oka, Richard; Mahar, Andrew
2003-01-01
The purpose of this study was to evaluate the structural and mechanical characteristics of a new and unique titanium cortical-cancellous helical compression anchor with BONE-LOK (Triage Medical, Inc., Irvine, CA) technology for compressive internal fixation of fractures and osteotomies. This device provides fixation through the use of a distal helical anchor and a proximal retentive collar that are united by an axially movable pin (U.S. and international patents issued and pending). The helical compression anchor (2.7-mm diameter) was compared with 3.0-mm diameter titanium cancellous screws (Synthes, Paoli, PA) for pullout strength and compression in 7# and 12# synthetic rigid polyurethane foam (simulated bone matrix), and for 3-point bending stiffness. The following results (mean +/- standard deviation) were obtained: foam block pullout strength in 12# foam: 2.7-mm helical compression anchor 70 +/- 2.0 N and 3.0-mm titanium cancellous screws 37 +/- 11 N; in 7# foam: 2.7-mm helical compression anchor 33 +/- 3 N and 3.0-mm titanium cancellous screws 31 +/- 12 N. Three-point bending stiffness, 2.7-mm helical compression anchor 988 +/- 68 N/mm and 3.0-mm titanium cancellous screws 845 +/- 88 N/mm. Compression strength testing in 12# foam: 2.7-mm helical compression anchor 70.8 +/- 4.8 N and 3.0-mm titanium cancellous screws 23.0 +/- 3.1 N, in 7# foam: 2.7-mm helical compression anchor 42.6 +/- 3.2 N and 3.0-mm titanium cancellous screws 10.4 +/- 0.9 N. Results showed greater pullout strength, 3-point bending stiffness, and compression strength for the 2.7-mm helical compression anchor as compared with the 3.0-mm titanium cancellous screws in these testing models. This difference represents a distinct advantage in the new device that warrants further in vivo testing.
Maynard, Jeffrey A; Anthony, Kenneth R N; Afatta, Siham; Dahl-Tacconi, Nancy; Hoegh-Guldberg, Ove
2010-10-01
Most of the world's coral reefs line the coasts of developing nations, where impacts from intense and destructive fishing practices form critical conservation issues for managers. Overfishing of herbivorous fishes can cause phase shifts to macroalgal dominance, and fishers' use of rocks as anchors lowers coral cover, giving further competitive advantage to macroalgae. Overfishing and anchoring have been studied extensively, but the role of their interaction in lowering coral reef resilience has not been quantified formally. We analyzed the combined effects of overfishing and rock anchoring on a range of reef habitat types--varying from high coral and low macroalgae cover to low coral and high macroalgae cover--in a marine park in Indonesia. We parameterized a model of coral and algal dynamics with three intensities of anchoring and fishing pressure. Results of the model indicated that damage caused by rock anchoring was equal to or possibly more devastating to coral reefs in the area than the impact of overfishing. This is an important outcome for local managers, who usually have the funds to distribute less-damaging anchors, but normally are unable to patrol regularly and effectively enough to reduce the impact of overfishing. We translated model results into an interactive visual tool that allows managers to explore the benefits of reducing anchoring frequency and fishing pressure. The potential consequences of inaction were made clear: the likelihood that any of the reef habitats will be dominated in the future by macroalgae rather than corals depends on reducing anchoring frequency, fishing pressure, or both. The tool provides a platform for strengthened relationships between managers and conservationists and can facilitate the uptake of recommendations regarding resource allocation and management actions. Conservation efforts for coral reefs in developing nations are likely to benefit from transforming model projections of habitat condition into tools local managers can understand and interact with. © 2010 Society for Conservation Biology.
ANTS-anchored Zn-Al-CO{sub 3}-LDH particles as fluorescent probe for sensing of folic acid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Pengfei; Liu, Dan; Liu, Yanhuan
2016-09-15
A novel fluorescent nanosensor for detecting folic acid (FA) in aqueous media has been developed based on 8-aminonaphthalene-1,3,6-trisulfonate (ANTS) anchored to the surface of Zn-Al-CO{sub 3}-layered double hydroxides (LDH) particles. The nanosensor showed high fluorescence intensity and good photostability due to a strong coordination interaction between surface Zn{sup 2+} ions of Zn-Al-CO{sub 3}-LDH and N atoms of ANTS, which were verified by result of X-ray photoelectron spectroscopy (XPS). ANTS-anchored on the surface of Zn-Al-CO{sub 3}-LDH restricted the intra-molecular rotation leading to ANTS-anchored J-type aggregation emission enhancement. ANTS-anchored Zn-Al-CO{sub 3}-LDH particles exhibited highly sensitive and selective response to FA over othermore » common metal ions and saccharides present in biological fluids. The proposed mechanism was that oxygen atoms of -SO{sub 3} groups in ANTS-anchored on the surface of Zn-Al-CO{sub 3}-LDH were easily collided by FA molecules to form potential hydrogen bonds between ANTS-anchored and FA molecules, which could effectively quench the ANTS-anchored fluorescence. Under the simulated physiological conditions (pH of 7.4), the fluorescence quenching was fitted to Stern-Volmer equation with a linear response in the concentration range of 1 μM to 200 μM with a limit of detection of 0.1 μM. The results indicate that ANTS-anchored Zn-Al-CO{sub 3}-LDH particles can afford a very sensitive system for the sensing FA in aqueous solution. - Highlights: • A novel fluorescent nanosensor has been developed. • The sensor exhibited highly sensitive and selective response to FA. • The fluorescence quenching was fitted to Stern–Volmer equation. • The linear response range was 1–200 μM with a limit of detection of 0.1 μM.« less
On the stiffness analysis of a cable driven leg exoskeleton.
Sanjeevi, N S S; Vashista, Vineet
2017-07-01
Robotic systems are being used for gait rehabilitation of patients with neurological disorder. These devices are externally powered to apply external forces on human limbs to assist the leg motion. Patients while walking with these devices adapt their walking pattern in response to the applied forces. The efficacy of a rehabilitation paradigm thus depends on the human-robot interaction. A cable driven leg exoskeleton (CDLE) use actuated cables to apply external joint torques on human leg. Cables are lightweight and flexible but can only be pulled, thus a CDLE requires redundant cables. Redundancy in CDLE can be utilized to appropriately tune a robot's performance. In this work, we present the stiffness analysis of CDLE. Different stiffness performance indices are established to study the role of system parameters in improving the human-robot interaction.
Anchored nanostructure materials and method of fabrication
Seals, Roland D; Menchhofer, Paul A; Howe, Jane Y; Wang, Wei
2012-11-27
Anchored nanostructure materials and methods for their fabrication are described. The anchored nanostructure materials may utilize nano-catalysts that include powder-based or solid-based support materials. The support material may comprise metal, such as NiAl, ceramic, a cermet, or silicon or other metalloid. Typically, nanoparticles are disposed adjacent a surface of the support material. Nanostructures may be formed as anchored to nanoparticles that are adjacent the surface of the support material by heating the nano-catalysts and then exposing the nano-catalysts to an organic vapor. The nanostructures are typically single wall or multi-wall carbon nanotubes.
Suture anchor repair of patellar tendon rupture after total knee arthroplasty.
Kamath, Atul F; Shah, Roshan P; Summers, Nathan; Israelite, Craig L
2013-12-01
Extensor mechanism disruption after total knee arthroplasty (TKA) is a complex problem that often requires surgical repair for functional deficits. We present a brief technical note on suture anchor fixation of a patellar tendon rupture after TKA. A surgical technique and literature review follows. Although suture anchor fixation is well described for tendinous repairs in other areas of orthopedic surgery, no study has discussed the use of suture anchors in patellar tendon repair after TKA. The technique must be evaluated in more patients with longer follow-up before adoption. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Studies on the wintertime current structure and T-S fine-structure in the Taiwan Strait
NASA Astrophysics Data System (ADS)
Hu, Jianyu; Fu, Zilang; Wu, Lianxing
1990-12-01
A cruise through the western sea area of the Taiwan Strait was carried out by the R/V Dong Fang Hong in December, 1987. Eight anchored and 10 not anchored stations were set up. Over 25 time-series current observations were made at each station and CTD (Conductivity-temperature-depth) measurements were made at 5 anchored and 10 not anchored stations. Based on the measured data. fine-structures and step-like vertical structures of temperature and salinity were analysed and a tentative wintertime current structure in the Taiwan Strait was described.
Anchoring energy of photo-sensitive polyimide alignment film containing methoxy cinnamate
NASA Astrophysics Data System (ADS)
Kim, Suyoung; Shin, Sung Eui; Shin, DongMyung
2010-02-01
Photosensitive polyimide containing 2-methoxy cinnamate was synthesized for photo-alignment layer of liquid crystals (LCs). 2-Methoxy cinnamic acid was confirmed photo-sensitive material by linearly polarized UV light. We studied that effect of polarized UV light on rubbed polyimide film. Anchoring energy of liquid crystal with aligning surface was measured. Irradiation of depolarized UV light on rubbed Polyimide film suppressed effective anchoring energy. Linearly polarized UV light on rubbed polyimide film controlled anchoring energy effectively. Polyimide film containing 2-methoxy cinnamate can control the photo-alignment layer easily due to its photo-sensitivity.
2014-05-21
PERSONNEL FROM STANDARD PRIME BEEF OR RED 4F9K4 PROVIDES FOLDED FIBERGLASS MATTING ( FFM ) FOR AIRFIELD DAMAGE REPAIR (ADR). PACKAGE CONSISTS OF THREE FFM ...SETS (54’ X 60’), ONE FFM SUPPORT TOOL KIT, UPPER BUSHINGS, ANCHOR BUSHINGS, ANCHOR BOLTS, AND TWO EA MC-7 AIR COMPRESSORS. EACH UTC WILL BE TASKED TO...OF 7 FOLDED FIBERGLASS MAT SETS (54 FT X 60 FT), 2 FFM SUPPORT TOOL KIT, UPPER BUSHINGS, ANCHOR BUSHINGS, ANCHOR BOLTS AND 4 X MC-7 AIR COMPRESSORS
Waldrop, Norman E; Wijdicks, Coen A; Jansson, Kyle S; LaPrade, Robert F; Clanton, Thomas O
2012-11-01
Despite the popularity of the Broström procedure for secondary repair of chronic lateral ankle instability, there have been no biomechanical studies reporting on the strength of this secondary repair method, whether using suture fixation or suture anchors. The purpose of our study was to perform a biomechanical comparison of the ultimate load to failure and stiffness of the traditional Broström technique using only a suture repair compared with a suture anchor repair of the anterior talofibular ligament (ATFL) at time zero. We believed that fixation strength of the suture anchor repair would be closer to the strength of the native ligament and allow more aggressive rehabilitation. Controlled laboratory study. Twenty-four fresh-frozen cadaveric ankles were randomly divided into 4 groups of 6 specimens. One group was an intact control group, and the other groups consisted of the traditional Broström and 2 suture anchor modifications (suture anchors in talus or fibula) of the Broström procedure. The specimens were loaded to failure to determine the strength and stiffness of each construct. In load-to-failure testing, ultimate failure loads of the Broström (68.2 ± 27.8 N; P = .013), suture anchor fibula (79.2 ± 34.3 N; P = .037), and suture anchor talus (75.3 ± 45.6 N; P = .027) repairs were significantly lower than that of the intact (160.9 ± 72.2 N) ATFL group. Stiffness of the Broström (6.0 ± 2.5 N/mm; P = .02), suture anchor fibula (6.8 N/mm ± 2.7; P = .05), and suture anchor talus (6.6 N/mm ± 4.0; P = .04) repairs were significantly lower than that of the intact (12.4 N/mm ± 4.1 N/mm) ATFL group. The 3 repair groups were not significantly different from each other, but all 3 were substantially lower in strength and stiffness when compared to the intact ATFL. The use of suture anchors to repair the ATFL produces a repair that can withstand loads to failure similar to the suture-only Broström repair. However, all 3 repair groups were much weaker than the intact, uninjured ATFL. Biomechanically, the results show that both suture anchor and direct suture repair of the ATFL provide similar strength and stiffness. Unfortunately, these methods provide less than half the strength and stiffness of the native ATFL at time zero. As a result, regardless of the repair method, it is necessary to sufficiently protect the repair to avoid premature failure.
Powis, Katie; Schrul, Bianca; Tienson, Heather; Gostimskaya, Irina; Breker, Michal; High, Stephen; Schuldiner, Maya; Jakob, Ursula; Schwappach, Blanche
2013-01-01
Summary The endomembrane system of yeast contains different tail-anchored proteins that are post-translationally targeted to membranes via their C-terminal transmembrane domain. This hydrophobic segment could be hazardous in the cytosol if membrane insertion fails, resulting in the need for energy-dependent chaperoning and the degradation of aggregated tail-anchored proteins. A cascade of GET proteins cooperates in a conserved pathway to accept newly synthesized tail-anchored proteins from ribosomes and guide them to a receptor at the endoplasmic reticulum, where membrane integration takes place. It is, however, unclear how the GET system reacts to conditions of energy depletion that might prevent membrane insertion and hence lead to the accumulation of hydrophobic proteins in the cytosol. Here we show that the ATPase Get3, which accommodates the hydrophobic tail anchor of clients, has a dual function: promoting tail-anchored protein insertion when glucose is abundant and serving as an ATP-independent holdase chaperone during energy depletion. Like the generic chaperones Hsp42, Ssa2, Sis1 and Hsp104, we found that Get3 moves reversibly to deposition sites for protein aggregates, hence supporting the sequestration of tail-anchored proteins under conditions that prevent tail-anchored protein insertion. Our findings support a ubiquitous role for the cytosolic GET complex as a triaging platform involved in cellular proteostasis. PMID:23203805
Experimental research on anchoring force in intestine for the motion of capsule robot.
Chen, Wenwen; Ke, Quan; He, Shu; Luo, Weijie; Ji, Xing Chun; Yan, Guozheng
2013-07-01
Multiple research groups are currently attempting to develop less-invasive robotic capsule endoscopes (RCEs) with better outcomes for enteroscopic procedures. Understanding the biomechanical response of the bowel to RCE is crucial for optimizing the design of these devices. For this reason, this study aims to develop an analytical model to predict the anchoring force of the model when travelling through the intestine. Previous work has developed, characterized and tested the frictional characteristics of the intestine with microgroove structures that had different surface contours. This work tested basic anchoring force characteristics with custom-built testers and clamping mechanism dummies to analyse the robot clamping movement (which is vital to improving movement efficiency). Balloon-shaped and leg-based clamping mechanisms were developed, which were found to have variable anchoring forces from 0.01 N to 1.2 N. After analysing the experimental results it was found that: (a) robot weight does not play a major role in anchoring force; (b) an increase in anchoring force corresponded to an increase in diameter of the clamping mechanism; and (c) textured contact surfaces effectively increased friction. These results could be explained by the biomechanical response of the intestine, friction and mucoadhesion characteristics of the small intestine material. With these factors considered, a model was developed for determining anchoring force in the small intestine.
Hazratwala, Kaushik; Best, Alistair; Kopplin, Matthew; Giza, Eric; Sullivan, Martin
2005-03-01
The modified Broström ligament reconstruction using anchor sutures has been performed in adults with clinical success; however, the safety parameters for the use of suture anchors in adolescent lateral ankle ligament reconstruction have not been established. To perform a radiographic analysis comparing the depth of penetration of suture anchors in adult ankle ligament reconstruction with the average distance of the physis from the tip of the fibula in adolescents. Cross-sectional study, Level of evidence, 4. Forty postoperative ankle radiographs of adult patients who had a modified Broström procedure were compared with 40 normal adolescent ankle radiographs. In the adult group, the distance of the suture anchor penetration from the distal tip of the fibula was measured; in the adolescent group, the distance of the physis from the distal tip of the fibula was measured. The mean depth of the suture anchors was 17 mm (range, 14-21 mm) from the tip of the fibula in the adult group, and the mean distance of the growth plate was 23 mm (range, 18-29 mm) in the adolescent group. Eight radiographs from the adolescent group (20%) had a physis measurement of <22 mm on the anteroposterior or mortise view. Using careful preoperative planning and intraoperative technique, it is possible to safely perform lateral ankle ligament repair in the skeletally immature patient using suture anchors.
NASA Astrophysics Data System (ADS)
Wang, Gang; Zhang, Yongzheng; Jiang, Yujing; Liu, Peixun; Guo, Yanshuang; Liu, Jiankang; Ma, Ming; Wang, Ke; Wang, Shugang
2018-06-01
To study shear failure, acoustic emission counts and characteristics of bolted jointed rock-like specimens are evaluated under compressive shear loading. Model joint surfaces with different roughnesses are made of rock-like material (i.e. cement). The jointed rock masses are anchored with bolts with different elongation rates. The characteristics of the shear mechanical properties, the failure mechanism, and the acoustic emission parameters of the anchored joints are studied under different surface roughnesses and anchorage conditions. The shear strength and residual strength increase with the roughness of the anchored joint surface. With an increase in bolt elongation, the shear strength of the anchored joint surface gradually decreases. When the anchored structural plane is sheared, the ideal cumulative impact curve can be divided into four stages: initial emission, critical instability, cumulative energy, and failure. With an increase in the roughness of the anchored joint surface, the peak energy rate and the cumulative number of events will also increase during macro-scale shear failure. With an increase in the bolt elongation, the energy rate and the event number increase during the shearing process. Furthermore, the peak energy rate, peak number of events and cumulative energy will all increase with the bolt elongation. The results of this study can provide guidance for the use of the acoustic emission technique in monitoring and predicting the static shear failure of anchored rock masses.
Schaaf, Marcel J M; Koopmans, Wiepke J A; Meckel, Tobias; van Noort, John; Snaar-Jagalska, B Ewa; Schmidt, Thomas S; Spaink, Herman P
2009-08-19
It has been possible for several years to study the dynamics of fluorescently labeled proteins by single-molecule microscopy, but until now this technology has been applied only to individual cells in culture. In this study, it was extended to stem cells and living vertebrate organisms. As a molecule of interest we used yellow fluorescent protein fused to the human H-Ras membrane anchor, which has been shown to serve as a model for proteins anchored in the plasma membrane. We used a wide-field fluorescence microscopy setup to visualize individual molecules in a zebrafish cell line (ZF4) and in primary embryonic stem cells. A total-internal-reflection microscopy setup was used for imaging in living organisms, in particular in epidermal cells in the skin of 2-day-old zebrafish embryos. Our results demonstrate the occurrence of membrane microdomains in which the diffusion of membrane proteins in a living organism is confined. This membrane organization differed significantly from that observed in cultured cells, illustrating the relevance of performing single-molecule microscopy in living organisms.
48 CFR 252.225-7019 - Restriction on acquisition of anchor and mooring chain.
Code of Federal Regulations, 2012 CFR
2012-10-01
... of anchor and mooring chain. 252.225-7019 Section 252.225-7019 Federal Acquisition Regulations System... and mooring chain. As prescribed in 225.7007-3, use the following clause: Restriction on Acquisition of Anchor and Mooring Chain (DEC 2009)) (a) Definition. “Component,” as used in this clause, means an...
48 CFR 252.225-7019 - Restriction on acquisition of anchor and mooring chain.
Code of Federal Regulations, 2013 CFR
2013-10-01
... of anchor and mooring chain. 252.225-7019 Section 252.225-7019 Federal Acquisition Regulations System... and mooring chain. As prescribed in 225.7007-3, use the following clause: Restriction on Acquisition of Anchor and Mooring Chain (DEC 2009)) (a) Definition. “Component,” as used in this clause, means an...
48 CFR 252.225-7019 - Restriction on acquisition of anchor and mooring chain.
Code of Federal Regulations, 2014 CFR
2014-10-01
... of anchor and mooring chain. 252.225-7019 Section 252.225-7019 Federal Acquisition Regulations System... and mooring chain. As prescribed in 225.7007-3, use the following clause: Restriction on Acquisition of Anchor and Mooring Chain (DEC 2009)) (a) Definition. “Component,” as used in this clause, means an...
The Empirical Selection of Anchor Items Using a Multistage Approach
ERIC Educational Resources Information Center
Craig, Brandon
2017-01-01
The purpose of this study was to determine if using a multistage approach for the empirical selection of anchor items would lead to more accurate DIF detection rates than the anchor selection methods proposed by Kopf, Zeileis, & Strobl (2015b). A simulation study was conducted in which the sample size, percentage of DIF, and balance of DIF…
The Double-Anchoring Theory of Lightness Perception: A Comment on Bressan (2006)
ERIC Educational Resources Information Center
Howe, Piers D. L.; Sagreiya, Hersh; Curtis, Dwight L.; Zheng, Chengjie; Livingstone, Margaret S.
2007-01-01
Comments on an article by Bressan. Recently, a double-anchoring theory (DAT) of lightness perception was proposed (P. Bressan, 2006), which offers explanations for all the data explained by the original anchoring theory (A. Gilchrist et al., 1999), as well as a number of additional lightness phenomena. Consequently, DAT can account for an…