Sample records for external fixator constructs

  1. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    PubMed

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  2. Bacteria on external fixators: which prep is best?

    PubMed

    Stinner, Daniel J; Beltran, Michael J; Masini, Brendan D; Wenke, Joseph C; Hsu, Joseph R

    2012-03-01

    There are no established guidelines for the surgical prep of an external fixator in the operative field. This study investigates the effectiveness of different prep solutions and methods of application. Forty external fixator constructs, consisting of a rod, pin, and pin to rod coupling device, were immersed in a broth of Staphylococcus aureus (lux) for 12 hours. Constructs were then randomized into four treatment groups: chlorhexidine-gluconate (CHG) (4%) scrub, CHG (4%) spray, povidone-iodine (PI) (10%) scrub, and PI (10%) spray. Each construct was imaged with a specialized photon capturing camera system yielding the quantitative and spatial distribution of bacteria both before and after the prep. Each pin to bar clamp was loosened and moved 2 cm down the construct, simulating an external fixator adjustment, and reimaged. Spatial distribution of bacteria and total bacteria counts were compared. There was a similar reduction in bacteria after surgical prep when comparing all four groups independently (p = 0.19), method of application (spray vs. scrub, p = 0.27), and different solutions (CHG vs. PI, p = 0.41). Although bacteria were evident in newly exposed areas after external fixator adjustment, most notably within the loosened pin to bar clamp, it did not result in an increase in bacteria counts (all four groups, p = 0.11; spray vs. scrub, p = 0.18; CHG vs. PI, p = 0.99). Although there was no increase in bacteria counts after the simulated external fixator adjustment, it did expose additional bacteria previously unseen. Although there was no difference in surgical prep solution or method of application, consideration must be given to performing an additional surgical prep of the newly exposed surface after loosening of each individual external fixator component as this may further minimize potential bacteria exposure.

  3. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    PubMed

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  4. A simple and inexpensive external fixator.

    PubMed

    Noor, M A

    1988-11-01

    A simple and inexpensive external fixator has been designed. It is constructed of galvanized iron pipe and mild steel bolts and nuts. It can easily be manufactured in a hospital workshop with a minimum of tools.

  5. Ball-joint versus single monolateral external fixators for definitive treatment of tibial shaft fractures.

    PubMed

    Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J

    2014-07-01

    To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.

  6. Biomechanics of far cortical locking.

    PubMed

    Bottlang, Michael; Feist, Florian

    2011-02-01

    The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.

  7. Biomechanics of Far Cortical Locking

    PubMed Central

    Bottlang, Michael; Feist, Florian

    2011-01-01

    The development of FCL was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biological fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have shown to enhance fixation and fracture healing: Flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80–88% to actively promote callus proliferation similar to an external fixator. Load distribution is evenly shared between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by s-shaped flexion of FCL screws has shown to induce symmetric callus formation. In combination, these features of FCL constructs have shown to induce more callus and to yield significantly stronger and more consistent healing compared to standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biological healing response of external fixators. PMID:21248556

  8. Biomechanics of Two External Fixator Devices Used in Rat Femoral Fractures.

    PubMed

    Osagie-Clouard, Liza; Kaufmann, Joshua; Blunn, Gordon; Coathup, Melanie; Pendegrass, Catherine; Meeson, Richard; Briggs, Timothy; Moazen, Mehran

    2018-05-04

    The use of external fixators allows for the direct investigation of newly formed interfragmentary bone, and the radiographic evaluation of the fracture. We validated the results of a finite element model with the in vitro stiffness' of two widely used external fixator devices used for in vivo analysis of fracture healing in rat femoral fractures with differing construction (Ti alloy ExFix1 and PEEK ExFix2). Rat femoral fracture fixation was modelled using two external fixators. For both constructs an osteotomy of 2.75 mm was used, and offset maintained at 5 mm. Tufnol, served as standardized substitutes for rat femora. Constructs were loaded under axial compression and torsion. Overall axial and torsional stiffness were compared between the in vitro models and FE results. FE models were also used to compare the fracture movement and overall pattern of von Mises stress across the external fixators. In vitro axial stiffness of ExFix1 was 29.26 N/mm ± 3.83 compared to ExFix2 6.31 N/mm ± 0.67 (p* < 0.05). Torsional stiffness of ExFix1 was 47.5 Nmm/° ± 2.71 compared to ExFix2 at 19.1 Nmm/° ± 1.18 (p* < 0.05). FE results predicted similar comparative ratios between the ExFix1 and 2 as the in vitro studies. FE results predicted considerably larger interfragmentary motion in the ExFix2 comparing to ExFix1. We demonstrated significant differences in the stiffness' of the two external fixators as one would expect from such variable designs; yet, importantly we validated the utility of an FE model for the analysis and prediction of changes in fracture mechanics dependent on fixator choice. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Determination of ankle external fixation stiffness by expedited interactive finite element analysis.

    PubMed

    Nielsen, Jonathan K; Saltzman, Charles L; Brown, Thomas D

    2005-11-01

    Interactive finite element analysis holds the potential to quickly and accurately determine the mechanical stiffness of alternative external fixator frame configurations. Using as an example Ilizarov distraction of the ankle, a finite element model and graphical user interface were developed that provided rapid, construct-specific information on fixation rigidity. After input of specific construct variables, the finite element software determined the resulting tibial displacement for a given configuration in typically 15s. The formulation was employed to investigate constructs used to treat end-stage arthritis, both in a parametric series and for five specific clinical distraction cases. Parametric testing of 15 individual variables revealed that tibial half-pins were much more effective than transfixion wires in limiting axial tibial displacement. Factors most strongly contributing to stiffening the construct included placing the tibia closer to the fixator rings, and mounting the pins to the rings at the nearest circumferential location to the bone. Benchtop mechanical validation results differed inappreciably from the finite element computations.

  10. Bladder incarceration following anterior pelvic infix of a traumatic pubic symphysis diastasis treated with immediate open reduction and internal fixation.

    PubMed

    Jain, Mantu; Nanda, Saurav Narayan; Mohapatra, Soumya Shrikanta; Samal, Barada Prasanna

    2017-08-01

    Stabilization after a pelvic fracture can be accomplished using multiple techniques. The anterior external fixator has been traditionally used in variety of unstable pelvis either singly or in combination of posterior screws. These devices are cumbersome and restrict side turning and sitting particularly in obese patients. An alternative, anterior subcutaneous pelvic internal fixation technique (ASPIF) was developed which is well tolerated by patients for mobility and comfort and biomechanically more stable construct Complications of this construct included irritation of the lateral femoral cutaneous nerve, femoral nerve palsy &heterotypic ossification with reduced rates of infections and aseptic loosening as compared to external fixator. Bladder incarceration following treatment has never been reported and we encountered such a problem during management which we want to highlight.

  11. Comparison of stability of different types of external fixation.

    PubMed

    Grubor, Predrag; Grubor, Milan; Asotic, Mithat

    2011-01-01

    Stabilization of fractures by external fixator is based on the mechanical connecting of the pins, screwed into the proximal and distal bone fragment. Site of fracture is left without any foreign materials, which is essential for prevention of infections. Aim of this work is to compare stability of constructs bone model-external fixators of different types (Ortofix, Mitković, Charneley and Ilizarov). Stability is estimated under compression and bending (vertical and horizontal forces of 100 kg magnitudes, with distances between pins of4 cm). The mathematical-computer software (Tower, Planet and Planet Pro) was used in the laboratory for accurate measurements of MDP "Jelsingrad" company, Banjaluka. Interfragmental motions in millimeters at the appliance of vertical and horizontal forces were 2.80/2.56 at Ortofix (uniplanar fixator), 1.57/1.56 and fixator by Mitković-M20 (uniplanar fixator with convergent oriented pins), 0.16/0.28 at Charnely's external fixator (biplanar fixator), and 4.49/0.114 mm at Ilizarov's external fixator (fixator with two proximal and two distal rings, each attached on the 6 Kirschner wires). It has confirmed that uniplanar fixation is easier and provides sufficient biomechanics circumstances in the site of fracture for bone healing, especially if the pins are oriented convergently. Ilizarov's fixator is multiplanar fixator, but its stability is dependent of tightness of wires, and provides adequate stability only in transversal plane. By other words, each fixator has its indications; selection of the fixator should be based on theirs mechanic characteristics, fracture geometry, and potential of bone healing, with permanent simplification of treatment, which has to be safe and acceptable for the patient. The main advantage of this study is Sits nature-the comparison of four most used external fixators, by the only one possible way-on the bone model. Each other way of comparison would result with much more questions than answers, due to unacceptable high bias of other parameters, which significantly influences on the results of the study.

  12. Analysis of strategies to increase external fixator stiffness: is double stacking worth the cost?

    PubMed

    Strebe, Sara; Kim, Hyunchul; Russell, Joseph P; Hsieh, Adam H; Nascone, Jason; O'Toole, Robert V

    2014-07-01

    We compared the mechanical benefits and costs of 3 strategies that are commonly used to increase knee-spanning external fixator stiffness (resistance to deformation): double stacking, cross-linking, and use of an oblique pin. At our academic trauma centre and biomechanical testing laboratory, we used ultra-high-molecular-weight polyethylene bone models and commercially available external fixator components to simulate knee-spanning external fixation. The models were tested in anterior-posterior bending, medial-lateral bending, axial compression, and torsion. We recorded the construct stiffness for each strategy in all loading modes and assessed a secondary outcome of cost per 10% increase in stiffness. Double stacking significantly increased construct stiffness under anterior-posterior bending (109%), medial-lateral bending (22%), axial compression (150%), and torsion (41%) (p<0.05). Use of an oblique pin significantly increased stiffness under torsion (25%) (p<0.006). Cross-linking significantly increased stiffness only under torsion (29%) (p<0.002). Double stacking increased costs by 84%, cross-linking by 28%, and use of an oblique pin by 15% relative to a standard fixator. All 3 strategies increased stiffness under torsion to varying degrees, but only double stacking increased stiffness in all 4 testing modalities (p<0.05). Double stacking is most effective in increasing resistance to bending, particularly under anterior-posterior bending and axial compression, but requires a relatively high cost increase. Clinicians can use these data to help guide the most cost-effective strategy to increase construct stiffness based on the plane in which stiffness is needed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Mechanical evaluation of external skeletal fixator-intramedullary pin tie-in configurations applied to cadaveral humeri from red-tailed hawks (Buteo jamaicensis).

    PubMed

    Van Wettere, Arnaud J; Redig, Patrick T; Wallace, Larry J; Bourgeault, Craig A; Bechtold, Joan E

    2009-12-01

    Use of external skeletal fixator-intramedullary pin (ESF-IM) tie-in fixators is an adjustable and effective method of fracture fixation in birds. The objective of this study was to determine the contribution of each of the following parameters to the compressive and torsional rigidity of an ESF-IM pin tie-in applied to avian bones with an osteotomy gap: (1) varying the fixation pin position in the proximal bone segment and (2) increasing the number of fixation pins in one or both bone segments. ESF-IM pin tie-in constructs were applied to humeri harvested from red-tailed hawks (Buteo jamaicensis) (n=24) that had been euthanatized for clinical reasons. Constructs with a variation in the placement of the proximal fixation pin and with 2, 3, or 4 fixation pins applied to avian bone with an osteotomy gap were loaded to a defined displacement in torque and axial compression. Response variables were determined from resulting load-displacement curves (construct stiffness, load at 1-mm displacement). Increasing the number of fixation pins from 1 to 2 per bone segment significantly increased the stiffness in torque (110%) and compression (60%), and the safe load in torque (107%) and compression (50%). Adding a fixation pin to the distal bone segment to form a 3-pin fixator significantly increased the stiffness (27%) and safe load (20%) in torque but not in axial compression. In the configuration with 2 fixation pins, placing the proximal pin distally in the proximal bone segment significantly increased the stiffness in torque (28%), and the safe load in torque (23%) and in axial compression (32%). Results quantified the relative importance of specific parameters affecting the rigidity of ESF-IM pin tie-in constructs as applied to unstable bone fracture models in birds.

  14. Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis

    PubMed Central

    Vaidya, Rahul; Onwudiwe, Ndidi; Roth, Matthew; Sethi, Anil

    2013-01-01

    Purpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic range, 2 to torsional failure and 3 in distraction until failure. Results. The pedicle screw systems showed higher stiffness (4.008 ± 0.113 Nmm monoaxial, 3.638 ± 0.108 Nmm Click-x; 3.634 ± 0.147 Nmm Pangea) than the exfix system (2.882 ± 0.054 Nmm) in distraction. In failure testing, monoaxial pedicle screw system was stronger (360 N) than exfixes (160 N) and polyaxial devices which failed if distracted greater than 4 cm (157 N Click-x or 138 N Pangea). The exfix had higher peak torque and torsional stiffness than all pedicle systems. In torsion, the yield strengths were the same for all constructs. Conclusion. The infix device constructed with polyaxial or monoaxial pedicle screws is stiffer than the 2 pin external fixator in distraction testing. In extreme cases, the use of reinforcement or monoaxial systems which do not fail even at 360 N is a better option. In torsional testing, the 2 pin external fixator is stiffer than the pedicle screw systems. PMID:24368943

  15. Monoaxial pedicle screws are superior to polyaxial pedicle screws and the two pin external fixator for subcutaneous anterior pelvic fixation in a biomechanical analysis.

    PubMed

    Vaidya, Rahul; Onwudiwe, Ndidi; Roth, Matthew; Sethi, Anil

    2013-01-01

    Purpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic range, 2 to torsional failure and 3 in distraction until failure. Results. The pedicle screw systems showed higher stiffness (4.008 ± 0.113 Nmm monoaxial, 3.638 ± 0.108 Nmm Click-x; 3.634 ± 0.147 Nmm Pangea) than the exfix system (2.882 ± 0.054 Nmm) in distraction. In failure testing, monoaxial pedicle screw system was stronger (360 N) than exfixes (160 N) and polyaxial devices which failed if distracted greater than 4 cm (157 N Click-x or 138 N Pangea). The exfix had higher peak torque and torsional stiffness than all pedicle systems. In torsion, the yield strengths were the same for all constructs. Conclusion. The infix device constructed with polyaxial or monoaxial pedicle screws is stiffer than the 2 pin external fixator in distraction testing. In extreme cases, the use of reinforcement or monoaxial systems which do not fail even at 360 N is a better option. In torsional testing, the 2 pin external fixator is stiffer than the pedicle screw systems.

  16. Bacteria on External Fixators: Which Prep is Best?

    DTIC Science & Technology

    2012-01-01

    aureus (lux). After 12 hours in the broth, a sufficient time to allow biofilm formation ,11 the constructs were individually removed and baseline imaging...difference when cleansing components consisting of stainless steel and alumi- num.15–17 We also found that a simulated external fixator adjustment exposed...Albert E, et al. Direct continuous method for monitoring biofilm infection in a mouse model. Infect Immun. 2003;71: 882–890. 11. Charles CA, Ricotti CA

  17. Biomechanical characteristics of fixation methods for floating pubic symphysis.

    PubMed

    Song, Wenhao; Zhou, Dongsheng; He, Yu

    2017-03-07

    Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.

  18. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.

    PubMed

    Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M

    2015-12-01

    This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.

  19. Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients.

    PubMed

    Anderson, Richard C E; Ragel, Brian T; Mocco, J; Bohman, Leif-Erik; Brockmeyer, Douglas L

    2007-07-01

    Atlantoaxial and occipitocervical instability in children have traditionally been treated with posterior bone and wire fusion and external halo orthoses. Recently, successful outcomes have been achieved using rigid internal fixation, particularly C1-2 transarticular screws. The authors describe flow diagrams created to help clinicians determine which method of internal fixation to use in complex anatomical circumstances when bilateral transarticular screw placement is not possible. The records of children who underwent either atlantoaxial or occipitocervical fixation with rigid internal fixation over an 11-year period were retrospectively reviewed to define flow diagrams used to determine treatment protocols. Among the 95 patients identified who underwent atlantoaxial or occipitocervical fixation, the craniocervical anatomy in 25 patients (six atlantoaxial and 19 occipitocervical fixations [26%]) required alternative methods of internal fixation. Types of screw fixation included loop or rod constructs anchored by combinations of C1-2 transarticular screws (15 constructs), C-1 lateral mass screws (11), C-2 pars screws (24), C-2 translaminar screws (one), and subaxial lateral mass screws (six). The mean age of the patients (15 boys and 10 girls) was 9.8 years (range 1.3-17 years). All 22 patients with greater than 3-month follow-up duration achieved solid bone fusion and maintained stable constructs on radiographic studies. Clinical improvement was seen in all patients who had preoperative symptoms. Novel flow diagrams are suggested to help guide selection of rigid internal fixation constructs when performing pediatric C1-2 and occipitocervical stabilizations. Use of these flow diagrams has led to successful fusion in 25 pediatric patients with difficult anatomy requiring less common constructs.

  20. Biomechanical monitoring of healing bone based on acoustic emission technology.

    PubMed

    Hirasawa, Yasusuke; Takai, Shinro; Kim, Wook-Cheol; Takenaka, Nobuyuki; Yoshino, Nobuyuki; Watanabe, Yoshinobu

    2002-09-01

    Acoustic emission testing is a well-established method for assessment of the mechanical integrity of general construction projects. The purpose of the current study was to investigate the usefulness of acoustic emission technology in monitoring the yield strength of healing callus during external fixation. Thirty-five patients with 39 long bones treated with external fixation were evaluated for fracture healing by monitoring load for the initiation of acoustic emission signal (yield strength) under axial loading. The major criteria for functional bone union based on acoustic emission testing were (1) no acoustic emission signal on full weightbearing, and (2) a higher estimated strength than body weight. The yield strength monitored by acoustic emission testing increased with the time of healing. The external fixator could be removed safely and successfully in 97% of the patients. Thus, the acoustic emission method has good potential as a reliable method for monitoring the mechanical status of healing bone.

  1. Use of an elastic transarticular external fixator construct for immobilization of the elbow joint.

    PubMed

    Vedrine, Bertrand

    2017-04-01

    Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation.

  2. Use of an elastic transarticular external fixator construct for immobilization of the elbow joint

    PubMed Central

    Vedrine, Bertrand

    2017-01-01

    Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation. PMID:28373726

  3. Mechanical rigidity of the Ortho-SUV frame compared to the Ilizarov frame in the correction of femoral deformity.

    PubMed

    Skomoroshko, Petr V; Vilensky, Victor A; Hammouda, Ahmed I; Fletcher, Matt D A; Solomin, Leonid N

    2015-04-01

    The Ortho-SUV frame (OSF) is a novel hexapod circular external fixator which draws upon the innovation of the Ilizarov method and the advantages of hexapod construction in the three-dimensional control of bone segments. Stability of fixation is critical to the success or failure of an external circular fixator for fracture or osteotomy healing. In vitro biomechanical modelling study was performed comparing the stability of the OSF under load in both original form and after dynamisation to the Ilizarov fixator in all zones of the femur utilising optimal frame configuration. A superior performance of the OSF in terms of resistance to deforming forces in both original and dynamised forms over that of the original Ilizarov fixator was found. The OSF shows higher rigidity than the Ilizarov in the control of forces acting upon the femur. This suggests better stabilisation of femoral fractures and osteotomies and thus improved healing with a reduced incidence of instability-related bone segment deformity, non-union and delayed union.

  4. Analysis of usage and associated cost of external fixators at an urban level 1 trauma centre.

    PubMed

    Chaus, George W; Dukes, Chase; Hak, David J; Mauffrey, Cyril; Mark Hammerberg, E

    2014-10-01

    To determine the usage, indication, duration, and cost associated with external fixation usage. Additionally, to show the significant cost associated with external fixator use and reinvigorate discussions on external fixator reuse. A retrospective review of a prospectively gathered trauma database was undertaken to identify all patients treated with external fixation frames for pelvic and lower extremity injuries between September 2007 and July 2010. We noted the indications for frame use, and we determined the average duration of external fixation for each indication. The cost of each frame was calculated from implant records. 341 lower extremity and pelvic fractures were treated with external fixation frames during the study period. Of these, 92% were used as temporary external fixation. The average duration of temporary external fixation was 10.5 days. The cost of external fixation frame components was $670,805 per year. The average cost per external fixation frame was $5900. The majority of external fixators are intended as temporary frames, in place for a limited period of time prior to definitive fixation of skeletal injuries. As such, most frames are not intended to withstand physiologic loads, nor are they expected provide a precise maintenance of reduction. Given the considerable expense associated with external fixation frame components, the practice of purchasing external fixation frame components as disposable "single-use" items appears to be somewhat wasteful. Level II. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Biomechanical and Cost Comparisons of Near-Far and Pin-Bar Constructs.

    PubMed

    Whitney Kluk, Augusta; Zhang, Tina; Russell, Joseph P; Kim, Hyunchul; Hsieh, Adam H; O'Toole, Robert V

    2017-03-01

    Orthopedic dogma states that external fixator stiffness is improved by placing 1 pin close to the fracture and 1 as distant as possible ("near-far"). This fixator construct is thought to be less expensive than placing pins a shorter distance apart and using "pin-bar" clamps that attach pins to outriggers. The authors therefore hypothesized that the near-far construct is stiffer and less expensive. They compared mechanical stiffness and costs of near-far and pin-bar constructs commonly used for temporary external fixation of femoral shaft fractures. Their testing model simulated femoral shaft fractures in damage control situations. Fourth-generation synthetic femora (n=18) were used. The near-far construct had 2 pins that were 106 mm apart, placed 25 mm from the gap on each side of the fracture. The pin-bar construct pins were 55 mm apart, placed 40 mm from the gap. Mechanical testing was performed on a material test system machine. Stiffness was determined in the linear portion of the load-displacement curve for both constructs in 4 modes: axial compression, torsional loading, frontal plane 3-point bending, and sagittal plane 3-point bending. Costs were determined from a 2012 price guide. Compared with the near-far construct, the pin-bar construct had stiffness increased by 58% in axial compression (P<.05) and by 52% in torsional loading (P<.05). The pin-bar construct increased cost by 11%. In contrast to the authors' hypothesis and existing orthopedic dogma, the near-far construct was less stiff than the pin-bar construct and was similarly priced. Use of the pin-bar construct is mechanically and economically reasonable. [Orthopedics. 2017; 40(2):e238-e241.]. Copyright 2016, SLACK Incorporated.

  6. [Comparison of external fixation with or without limited internal fixation for open knee fractures].

    PubMed

    Li, K N; Lan, H; He, Z Y; Wang, X J; Yuan, J; Zhao, P; Mu, J S

    2018-03-01

    Objective: To explore the characteristics and methods of different fixation methods and prevention of open knee joint fracture. Methods: The data of 86 cases of open knee joint fracture admitted from January 2002 to December 2015 in Department of Orthopaedics, Affiliated Hospital of Chengdu University were analyzed retrospectively.There were 65 males and 21 females aged of 38.6 years. There were 38 cases treated with trans articular external fixation alone, 48 cases were in the trans articular external fixation plus auxiliary limited internal fixation group. All the patients were treated according to the same three stages except for different fixation methods. Observation of external fixation and fracture fixation, fracture healing, wound healing and treatment, treatment and related factors of infection control and knee function recovery. χ(2) test was used to analyze data. Results: Eleven patients had primary wound healing, accounting for 12.8%. Seventy-five patients had two wounds healed, accounting for 87.2%. Only 38 cases of trans articular external fixator group had 31 cases of articular surface reduction, accounting for 81.6%; Five cases of trans articular external fixator assisted limited internal fixation group had 5 cases of poor reduction, accounting for 10.4%; There was significant difference between the two groups (χ(2)=44.132, P <0.05). Take a single cross joint external fixation group, a total of 23 cases of patients with infection, accounted for 60.5% of external fixation group; trans articular external fixation assisted limited internal fixation group there were 30 cases of patients with infection, accounting for the assistance of external fixator and limited internal fixation group 62.5%; There was significant difference between the two groups(χ(2)=0.035, P >0.05). Five cases of fracture nonunion cases of serious infection, patients voluntarily underwent amputation. The Lysholm Knee Scale: In the external fixation group, 23 cases were less than 50 points, accounting for 60.5%, 15 cases were more than 50 points, accounting for 39.5%, external fixation and limited internal fixation group 20 cases were less than 50 points, accounting for 41.7%, 28 cases were more than 50 points, accounting for 58.3%; There was significant difference between the two groups(χ(2)=1.279, P >0.05). Conclusions: Prevention and control of infection is a central link in the treatment of open fracture of the knee. Trans articular external fixator plus limited internal fixation is an important measure to treat open fracture of the knee-joint.

  7. [Domestic external fixator application in the treatment of limb deformities: 7 289 cases application report].

    PubMed

    Qin, S H; Guo, B F; Zheng, X J; Jiao, S F; Xia, H T; Peng, A M; Pan, Q; Zang, J C; Wang, Z J

    2017-09-01

    Objective: To discuss the clinical application and effects of domestic external fixator in the treatment of patients with malformations of limbs. Methods: A total of 7 289 patients with malformation of limbs who had been operated in Qin Sihe orthopedic surgery team from January 1989 to June 2016 were retrospective analyzed. The patients were treated with domestic external fixator, including 4 033 males and 3 256 females, aging from 2 to 82 years with a mean age of 23.4 years. There were 2 732 patients using Ilizarov external fixator, 4 713 patients using hybrid external fixator, 57 patients using monobrachial external fixator, 232 patients using Ilizarov external fixator and hybrid external fixator. The Ilizarov, hybrid and monobrachial external fixator were used in 67, 65 and 0 patients on the upper limbs and in 2 665, 4 616 and 57 patients on the lower limbs. There were 3 028 patients operated on the left limbs, 3 260 patients operated on the right limbs and 1 001 patients operated on the bilateral limbs. The top three types of diseases were sequelae of poliomyelitis, cerebral palsy and post-traumatic stress disorder peromely. Deformity types inclued talipes equinovarus, knee flexion deformity, cavus foot and so on. Results: All the patients were followed up for a period of 2.5 months to 22.4 years, with an average follow-up time of 5.4 years. All of the external fixators were used for single once, and there was no substitute for external fixator quality problem. All the patients were completed surgery goal until removing external fixation except 1 patient gave up treatment and 1 removed the fixator because of metal allergy. The common complications included wire or pin infection and joint movement limitation and so on. Conclusions: The domestic external fixator developed and produced based on the characteristics of Chinese limb deformity disability. The domestic external fixator can be used to treat kinds of limb deformities with the advantages of practical, economical, adjustable, universal and portable. The domestic external fixator could meet the clinical demand for fixation of the osteotomy end of the limbs, the correction of the deformity, the repair of the defects and the limb lengthening.

  8. Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures

    PubMed Central

    Kopylov, Philippe; Geijer, Mats; Tägil, Magnus

    2009-01-01

    Background and purpose In unstable distal radial fractures that are impossible to reduce or to maintain in reduced position, the treatment of choice is operation. The type of operation and the choice of implant, however, is a matter of discussion. Our aim was to investigate whether open reduction and internal fixation would produce a better result than traditional external fixation. Methods 50 patients with an unstable or comminute distal radius fracture were randomized to either closed reduction and bridging external fixation, or open reduction and internal fixation using the TriMed system. The primary outcome parameter was grip strength, but the patients were followed for 1 year with objective clinical assessment, subjective outcome using DASH, and radiographic examination. Results At 1 year postoperatively, grip strength was 90% (SD 16) of the uninjured side in the internal fixation group and 78% (17) in the external fixation group. Pronation/supination was 150° (15) in the internal fixation group and 136° (20) in the external fixation group at 1 year. There were no differences in DASH scores or in radiographic parameters. 5 patients in the external fixation group were reoperated due to malunion, as compared to 1 in the internal fixation group. 7 other cases were classified as radiographic malunion: 5 in the external fixation group and 2 in the internal fixation group. Interpretation Internal fixation gave better grip strength and a better range of motion at 1 year, and tended to have less malunions than external fixation. No difference could be found regarding subjective outcome. PMID:19857180

  9. Hybrid Fixation for Ankle Fusion in Diabetic Charcot Arthropathy.

    PubMed

    El-Mowafi, Hani; Abulsaad, Mazen; Kandil, Yasser; El-Hawary, Ahmed; Ali, Samer

    2018-01-01

    Ankle fusion is difficult to achieve in the diabetic Charcot ankle Brodsky type 3a because of the poor quality of the bone and the inability to achieve a stable biomechanical construct. The aim of this study was to report the outcome of ankle fusion using a combination of an intramedullary nail and a circular external fixator in patients with diabetic Charcot arthropathy. We prospectively studied 24 patients with diabetic Charcot arthropathy of the ankle who were treated by fusion of the tibiotalar joint using a combined retrograde intramedullary nail and Ilizarov external fixator. Their mean age was 50.7 ± 6.9 (range, 43-62) years. The mean follow-up after surgery was 36.4 ± 5.8 (range, 24-98) months. Twenty-two patients (92%) achieved clinical and radiographic solid bony fusion. No patients in this series needed amputation. All the patients were pain free, and the mean American Orthopaedic Foot & Ankle Society Score (AOFAS) improved significantly from 34.6 ± 6.8 to 66.4 ± 4.5 at the last follow-up. Two patients developed an ulcer over the heel due to a prominent nail. The ulcer healed after nail removal. Eight patients developed pin tract infection. We report a successful outcomes of ankle fusions using combined intramedullary nail locked only proximally and ring external fixator (hybrid fixation) in patients with diabetic Charcot arthropathy. Level IV, case series.

  10. [Results of femoral lengthening over an intramedullary nail and external fixator].

    PubMed

    Jasiewicz, Barbara; Kacki, Wojciech; Tesiorowski, Maciej; Potaczek, Tomasz

    2008-01-01

    Current techniques of operative limb lengthening usually are based on distraction osteogenesis. One of the techniques is limb lengthening over an intramedullary nail. The goal of this study is to evaluate the results of femoral lengthening over an intramedullary nail. Between 1999 and 200619 femoral "over nail" lengthenings were performed. There were 7 males and 12 females. Mean patients' age at surgery was 15.8 years, and mean initial femoral shortening was 5.1 cm. Operative technique consisted of one-stage implantation of intramedullary nail and external fixator. Ilizarov apparatus was used in 9 patients, monolateral fixator in 10 cases--ORTHOFIX in 9 patients, Wagner fixator--in 1 patient. Intramedullary nail was locked proximally with screws or Schanz pins from external fixator. After distraction phase, external fixator was removed and distal locking screws were applied. Evaluation criteria: obtained lengthening, time of external fixator, treatment time, healing index, external fixation index, range of motion in hip and knee joints and complications according to Paley. The mean lengthening was 4.6 cm, and mean distraction time was 66.6 days. Mean time of external fixation was 115.5 days, and external fixation index was 26.2 days for centimeter. Healing index was 36.9 days for centimeter. In cases with monolateral fixator, healing index did not differ with the whole group. During treatment 18 complications occurred, for a rate of 0.9 complication per segment. Lengthening over an intramedullary nail reduces the time of external fixator. Over nail femoral lengthening can prevent axis deviation following regenerate bending. Complication rate is similar to lengthenings with the classic Ilizarov technique. There are no differences in the treatment time in relation to the type of external fixator.

  11. Biomechanical Comparison of External Fixation and Compression Screws for Transverse Tarsal Joint Arthrodesis.

    PubMed

    Latt, L Daniel; Glisson, Richard R; Adams, Samuel B; Schuh, Reinhard; Narron, John A; Easley, Mark E

    2015-10-01

    Transverse tarsal joint arthrodesis is commonly performed in the operative treatment of hindfoot arthritis and acquired flatfoot deformity. While fixation is typically achieved using screws, failure to obtain and maintain joint compression sometimes occurs, potentially leading to nonunion. External fixation is an alternate method of achieving arthrodesis site compression and has the advantage of allowing postoperative compression adjustment when necessary. However, its performance relative to standard screw fixation has not been quantified in this application. We hypothesized that external fixation could provide transverse tarsal joint compression exceeding that possible with screw fixation. Transverse tarsal joint fixation was performed sequentially, first with a circular external fixator and then with compression screws, on 9 fresh-frozen cadaveric legs. The external fixator was attached in abutting rings fixed to the tibia and the hindfoot and a third anterior ring parallel to the hindfoot ring using transverse wires and half-pins in the tibial diaphysis, calcaneus, and metatarsals. Screw fixation comprised two 4.3 mm headless compression screws traversing the talonavicular joint and 1 across the calcaneocuboid joint. Compressive forces generated during incremental fixator foot ring displacement to 20 mm and incremental screw tightening were measured using a custom-fabricated instrumented miniature external fixator spanning the transverse tarsal joint. The maximum compressive force generated by the external fixator averaged 186% of that produced by the screws (range, 104%-391%). Fixator compression surpassed that obtainable with screws at 12 mm of ring displacement and decreased when the tibial ring was detached. No correlation was found between bone density and the compressive force achievable by either fusion method. The compression across the transverse tarsal joint that can be obtained with a circular external fixator including a tibial ring exceeds that which can be obtained with 3 headless compression screws. Screw and external fixator performance did not correlate with bone mineral density. This study supports the use of external fixation as an alternative method of generating compression to help stimulate fusion across the transverse tarsal joints. The findings provide biomechanical evidence to support the use of external fixation as a viable option in transverse tarsal joint fusion cases in which screw fixation has failed or is anticipated to be inadequate due to suboptimal bone quality. © The Author(s) 2015.

  12. Computer-aided surgical planner for a new bone deformity correction device using axis-angle representation.

    PubMed

    Wu, Ying Ying; Plakseychuk, Anton; Shimada, Kenji

    2014-11-01

    Current external fixators for distraction osteogenesis (DO) are unable to correct all types of deformities in the lower limb and are difficult to use because of the lack of a pre-surgical planning system. We propose a DO system that consists of a surgical planner and a new, easy-to-setup unilateral fixator that not only corrects all lower limb deformity, but also generates the contralateral/predefined bone shape. Conventionally, bulky constructs with six or more joints (six degrees of freedom, 6DOF) are needed to correct a 3D deformity. By applying the axis-angle representation, we can achieve that with a compact construct with only two joints (2DOF). The proposed system makes use of computer-aided design software and computational methods to plan and simulate the planned procedure. Results of our stress analysis suggest that the stiffness of our proposed fixator is comparable to that of the Orthofix unilateral external fixator. We tested the surgical system on a model of an adult deformed tibia and the resulting bone trajectory deviates from the target bone trajectory by 1.8mm, which is below our defined threshold error of 2mm. We also extracted the transformation matrix that defines the deformity from the bone model and simulated the planned procedure. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Comparison of effects of seven treatment methods for distal radius fracture on minimizing complex regional pain syndrome

    PubMed Central

    Sun, Tao

    2016-01-01

    Introduction Using network meta-analysis, we evaluated the adverse effects of the seven most common treatment methods, i.e., bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating, by their associated risk of developing complex regional pain syndrome (CRPS) in distal radius fracture (DRF) patients. Material and methods Following an exhaustive search of scientific literature databases for high quality studies, randomized controlled trials (RCTs) related to our study topic were screened and selected based on stringent predefined inclusion and exclusion criteria. Data extracted from the selected studies were used for statistical analyses using Stata 12.0 software. Results A total of 17 RCTs, including 1658 DRF patients, were enrolled in this network meta-analysis. Among the 1658 DRF patients, 452 received bridging external fixation, 525 received non-bridging external fixation, 154 received K-wire fixation, 84 received plaster fixation, 132 received dorsal plating, 123 received volar plating, and 188 received dorsal and volar plating. When compared to bridging external fixation patients, there was no marked difference in the CRPS risk in DRF patients receiving different treatments (all p > 0.05). However, the surface under the cumulative ranking curves (SUCRA) for plaster fixation (77.0%) and non-bridging external fixation (71.3%) were significantly higher compared with the other five methods. Conclusions Our findings suggest that compared with bridging external fixation, K-wire fixation, dorsal plating, volar plating, dorsal and volar plating, plaster fixation and non-bridging external fixation might be the better treatment methods to reduce the risk of CRPS in DRF patients. PMID:28144268

  14. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    PubMed

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P <0.05). There were no statistically significant differences observed between two approaches with respect to nounion, re-operation, complex regional pain syndrome, carpal tunnel syndrome, neurapraxia, tendonitis, painful hardware, scar( P >0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  15. An alternative technique for transosseous calcaneal pinning in external fixation.

    PubMed

    DiDomenico, Lawrence A; Giagnacova, Albert; Cross, Davina J; Ziran, Bruce H

    2012-01-01

    The authors describe a technique in which two 5.5-mm pins are inserted from the posterior aspect of the calcaneus and advanced anteriorly on a slightly convergent vector. The 2 points of fixation, with a 5/8 ring, provide a "steering wheel" effect allowing for leverage and control of the hindfoot and ankle. The construct also allows for offloading of the posterior calcaneus. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome.

    PubMed

    Pan, M; Chai, L; Xue, F; Ding, L; Tang, G; Lv, B

    2017-07-01

    The aim of this study was to compare the biomechanical stability and clinical outcome of external fixator combined with limited internal fixation (EFLIF) and open reduction and internal fixation (ORIF) in treating Sanders type 2 calcaneal fractures. Two types of fixation systems were selected for finite element analysis and a dual cohort study. Two fixation systems were simulated to fix the fracture in a finite element model. The relative displacement and stress distribution were analysed and compared. A total of 71 consecutive patients with closed Sanders type 2 calcaneal fractures were enrolled and divided into two groups according to the treatment to which they chose: the EFLIF group and the ORIF group. The radiological and clinical outcomes were evaluated and compared. The relative displacement of the EFLIF was less than that of the plate (0.1363 mm to 0.1808 mm). The highest von Mises stress value on the plate was 33% higher than that on the EFLIF. A normal restoration of the Böhler angle was achieved in both groups. No significant difference was found in the clinical outcome on the American Orthopedic Foot and Ankle Society Ankle Hindfoot Scale, or on the Visual Analogue Scale between the two groups (p > 0.05). Wound complications were more common in those who were treated with ORIF (p = 0.028). Both EFLIF and ORIF systems were tested to 160 N without failure, showing the new construct to be mechanically safe to use. Both EFLIF and ORIF could be effective in treating Sanders type 2 calcaneal fractures. The EFLIF may be superior to ORIF in achieving biomechanical stability and less blood loss, shorter surgical time and hospital stay, and fewer wound complications. Cite this article : M. Pan, L. Chai, F. Xue, L. Ding, G. Tang, B. Lv. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome. Bone Joint Res 2017;6:433-438. DOI: 10.1302/2046-3758.67.2000640. © 2017 Xue et al.

  17. Comparison of Monolateral External Fixation and Internal Fixation for Skeletal Stabilisation in the Management of Small Tibial Bone Defects following Successful Treatment of Chronic Osteomyelitis.

    PubMed

    Wang, Yicun; Jiang, Hui; Deng, Zhantao; Jin, Jiewen; Meng, Jia; Wang, Jun; Zhao, Jianning; Sun, Guojing; Qian, Hongbo

    2017-01-01

    To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled.

  18. Comparison of Monolateral External Fixation and Internal Fixation for Skeletal Stabilisation in the Management of Small Tibial Bone Defects following Successful Treatment of Chronic Osteomyelitis

    PubMed Central

    Wang, Yicun; Jiang, Hui; Deng, Zhantao; Meng, Jia; Wang, Jun

    2017-01-01

    Background To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. Methods 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Results Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. Conclusions It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled. PMID:29333448

  19. Distal tibial pilon fractures (AO/OTA type B, and C) treated with the external skeletal and minimal internal fixation method.

    PubMed

    Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan

    2013-09-01

    Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In fractures types B and C dynamic external skeletal fixation allows early mobility in the ankle joint.

  20. A Prospective Randomized Trial to Assess Fixation Strategies for Severe Open Tibia Fractures: Modern Ring External Fixators Versus Internal Fixation (FIXIT Study).

    PubMed

    OʼToole, Robert V; Gary, Joshua L; Reider, Lisa; Bosse, Michael J; Gordon, Wade T; Hutson, James; Quinnan, Stephen M; Castillo, Renan C; Scharfstein, Daniel O; MacKenzie, Ellen J

    2017-04-01

    The treatment of high-energy open tibia fractures is challenging in both the military and civilian environments. Treatment with modern ring external fixation may reduce complications common in these patients. However, no study has rigorously compared outcomes of modern ring external fixation with commonly used internal fixation approaches. The FIXIT study is a prospective, multicenter randomized trial comparing 1-year outcomes after treatment of severe open tibial shaft fractures with modern external ring fixation versus internal fixation among men and women of ages 18-64. The primary outcome is rehospitalization for major limb complications. Secondary outcomes include infection, fracture healing, limb function, and patient-reported outcomes including physical function and pain. One-year treatment costs and patient satisfaction will be compared between the 2 groups, and the percentage of Gustilo IIIB fractures that can be salvaged without soft tissue flap among patients receiving external fixation will be estimated.

  1. The structure and functioning of Dynastab DK - K fixator (knee joint) and its usefullness in clinical use.

    PubMed

    Deszczyński, J; Karpiński, J; Deszczyńska, H

    1999-12-30

    The autor describes following stages of research on external fixator Dynastab DK - K (knee joint) with in - built artificial joint enabling physiological range of movement of the knee and the use of the device in functional treatment of articular fractures of the knee. The final clinical prototype of the device was developed according to the results of the experiments with anatomical preparations of knee joints in which the trajectory of the physiological movement of the knee was stated. These observations were used to construct mechanical joint with the range of movement adequate to this of the healthy knee. The positive and negative aspects in DK - K fixator are also described. The fixator was appled in 6 difficult cases of articular fractures of knee with good results.

  2. Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.

    PubMed

    Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F

    2015-03-31

    This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P < 0.05); however, there were no significant differences in radial-ulnar deviation, wrist range of motion, or wrist function score between groups (P > 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.

  3. Correction of complex equino cavo varus foot deformity in skeletally mature patients by Ilizarov external fixation versus staged external-internal fixation.

    PubMed

    Emara, Khaled; El Moatasem, El Hussein; El Shazly, Ossama

    2011-12-01

    Complex foot deformity is a multi-planar foot deformity with many etiologic factors. Different corrective procedures using Ilizarov external fixation have been described which include, soft tissue release, V-osteotomy, multiple osteotomies and triple fusion. In this study we compare the results of two groups of skeletally mature patients with complex foot deformity who were treated by two different protocols. The first group (27 patients, 29 feet) was treated by triple fusion fixed by Ilizarov external fixator until union. The second group (29 patients, 30 feet), was treated by triple fusion with initial fixation by Ilizarov external fixation until correction of the deformity was achieved clinically, and then the Ilizarov fixation was replaced by internal fixation using percutaneous screws. Both groups were compared as regard the surgical outcome and the incidence of complications. There was statistically significant difference between the two groups regarding duration of external fixation and duration of casting with shorter duration in the group 2. Also there was statistically significant difference between both groups regarding pin tract infection with less incidence in group 2. Early removal of Ilizarov external fixation after correction of the deformity and percutaneous internal fixation using 6.5 cannulated screws can shorten the duration of treatment and be more comfortable for the patient with a low risk of recurrence or infection. Copyright © 2010 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  4. Numerical investigations of MRI RF field induced heating for external fixation devices

    PubMed Central

    2013-01-01

    Background The magnetic resonance imaging (MRI) radio frequency (RF) field induced heating on external fixation devices can be very high in the vicinity of device screws. Such induced RF heating is related to device constructs, device placements, as well as the device insertion depth into human subjects. In this study, computational modeling is performed to determine factors associated with such induced heating. Methods Numerical modeling, based on the finite-difference time-domain (FDTD) method, is used to evaluate the temperature rises near external device screw tips inside the ASTM phantom for both 1.5-T and 3-T MRI systems. The modeling approach consists of 1) the development of RF coils for 1.5-T and 3-T, 2) the electromagnetic simulations of energy deposition near the screw tips of external fixation devices, and 3) the thermal simulations of temperature rises near the tips of these devices. Results It is found that changing insertion depth and screw spacing could largely affect the heating of these devices. In 1.5-T MRI system, smaller insertion depth and larger pin spacing will lead to higher temperature rise. However, for 3-T MRI system, the relation is not very clear when insertion depth is larger than 5 cm or when pin spacing became larger than 20 cm. The effect of connection bar material on device heating is also studied and the heating mechanism of the device is analysed. Conclusions Numerical simulation is used to study RF heating for external fixation devices in both 1.5-T and 3-T MRI coils. Typically, shallower insertion depth and larger pin spacing with conductive bar lead to higher RF heating. The heating mechanism is explained using induced current along the device and power decay inside ASTM phantom. PMID:23394173

  5. The comparative risk of developing postoperative complications in patients with distal radius fractures following different treatment modalities

    PubMed Central

    Qiu, Wen-Jun; Li, Yi-Fan; Ji, Yun-Han; Xu, Wei; Zhu, Xiao-Dong; Tang, Xian-Zhong; Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei

    2015-01-01

    In this study, we performed a network meta-analysis to compare the outcomes of seven most common surgical procedures to fix DRF, including bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating. Published studies were retrieved through PubMed, Embase and Cochrane Library databases. The database search terms used were the following keywords and MeSH terms: DRF, bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating. The network meta-analysis was performed to rank the probabilities of postoperative complication risks for the seven surgical modalities in DRF patients. This network meta-analysis included data obtained from a total of 19 RCTs. Our results revealed that compared to DRF patients treated with bridging external fixation, marked differences in pin-track infection (PTI) rate were found in patients treated with plaster fixation, volar plating, and dorsal and volar plating. Cluster analysis showed that plaster fixation is associated with the lowest probability of postoperative complication in DRF patients. Plaster fixation is associated with the lowest risk for postoperative complications in DRF patients, when compared to six other common DRF surgical methods examined. PMID:26549312

  6. Circular External Fixation as a Primary or Adjunctive Therapy for the Podoplastic Approach of the Diabetic Charcot Foot.

    PubMed

    Short, Daniel J; Zgonis, Thomas

    2017-01-01

    Numerous techniques have been described for surgical management of the diabetic Charcot foot. External fixation has become a main surgical tool for the reconstructive foot and ankle surgeon when dealing with the ulcerated diabetic Charcot foot. In the presence of an open wound and/or osteomyelitis, staged reconstruction with circular external fixation becomes ideal for salvage of the diabetic lower extremity. Also, circular external fixation can provide simultaneous compression and stabilization, correct the underlying osseous or soft tissue deformities, and surgically offload the diabetic Charcot foot. This article describes a variety of circular external fixation applications for the diabetic Charcot foot. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Antimicrobial efficacy of external fixator pins coated with a lipid stabilized hydroxyapatite/chlorhexidine complex to prevent pin tract infection in a goat model.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dejong, E. Schuyler; Deberardino, T. M.; Brooks, D. E.

    Background: Pin tract infection is a common complication of external fixation. An antiinfective external fixator pin might help to reduce the incidence of pin tract infection and improve pin fixation. Methods: Stainless steel and titanium external fixator pins, with and without a lipid stabilized hydroxyapatite/chlorhexidine coating, were evaluated in a goat model. Two pins contaminated with an identifiable Staphylococcus aureus strain were inserted into each tibia of 12 goats. The pin sites were examined daily. On day 14, the animals were killed, and the pin tips cultured. Insertion and extraction torques were measured. Results: Infection developed in 100% of uncoatedmore » pins, whereas coated pins demonstrated 4.2% infected, 12.5% colonized, and the remainder, 83.3%, had no growth (p < 0.01). Pin coating decreased the percent loss of fixation torque over uncoated pins (p = 0.04). Conclusion: These results demonstrate that the lipid stabilized hydroxyapatite/chlorhexidine coating was successful in decreasing infection and improving fixation of external fixator pins.« less

  8. Tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator

    PubMed Central

    Kim, Hayoung; Kim, Kap Jung; Ahn, Jae Hoon; Choy, Won Sik; Kim, Yong In; Koo, Jea Yun

    2008-01-01

    The aim of this study was to evaluate the efficacy of tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator for the treatment of leg length discrepancy or short stature. This retrospective study was performed on 18 tibiae (13 patients) in which attempts were made to reduce complications. We used an Ilizarov external fixator and a nail (10 mm diameter in 17 tibiae and 11 mm in one tibia) in combination. Average limb lengthening was 4.19 cm (range, 2.5–5.5). The mean duration of external fixation was 12.58 days per centimetre gain in length, and the mean consolidation index was 40.53 (range, 35.45–51.85). All distracted segments healed spontaneously without refracture or malalignment. Gradual limb lengthening using a reamed type intramedullary nail and circular external fixation in combination was found to be reliable and effective and reduced external fixation time with fewer complications. PMID:18415098

  9. Limb lengthening over a nail can safely reduce the duration of external fixation

    PubMed Central

    Chaudhary, Milind

    2008-01-01

    Background: Limb lengthening using Ilizarov external fixation is safe, but the consolidation phase tends to take too long. A method that can safely reduce the time spent in external fixation would help increase patient tolerance and comfort. We report our results of lengthening over nails (LON) method in which an interlocking nail was used along with an Ilizarov external fixator to reduce external fixation duration in limb lengthening. This is a retrospective study. Materials and Methods: Twenty-seven lengthening surgeries were done with the LON method in 23 patients with 22 tibiae and five femora during the last 12 years. Length gain ranged from 1.5 cm to a maximum of 9.8 cm with a mean of 4.6 cm. The mean modified Paley difficulty score was 7.6 points. Fourteen associated procedures were performed in these patients, including equinus contracture releases, supracondylar osteotomies, ilizarov hip reonstruction and ankle fusion. We had a 29% rate of complications which included one problem, three obstacles and four complications with no serious deep intramedullary infections. Our rate of complications compares favorably with series reported in the literature. External fixation duration was reduced significantly to a mean of 17.8 days per cm. Conclusions: A combination of intramedullary nailing along with external fixation significantly reduces external fixation time while maintaining low rate of complications. Great care needs to be taken to prevent pin track infection and deep intramedullary sepsis. PMID:19753160

  10. [Case-control study on effects of external fixation combined with limited internal fixation for the treatment of Pilon fractures of Rüedi-Allgower type III].

    PubMed

    Duan, Da-Peng; You, Wu-Lin; Ji, Le; Zhang, Yong-Tao; Dang, Xiao-Qian; Wang, Kun-Zheng

    2014-01-01

    To analyze the effects of three surgical operations in the treatment of Pilon fracture of Rüedi-Allgower type III, and put forward the best therapeutic method. The clinical data of 33 patients with Pilon fracture who received surgical operations (plaster immobilization group, 10 cases; distal tibia anatomical plate group, 11 cases; external fixation with limited internal fixation group, 12 cases) from October 2009 to January 2012 were analyzed. There were 5 males and 5 females, ranging in age from 24 to 61 years in the plaster immobilization group. There were 7 males and 4 females, ranging in age from 21 to 64 years in the distal tibia anatomical plate group. There were 7 males and 5 females, ranging in age from 23 to 67 years in the external fixation with limited internal fixation group. The Ankle X-ray of Pilon fracture after operation, ankle score, early and late complications were collected. Bourne system was used to evaluate ankle joint function. After 8 months to 3 years follow-up, it was found that three kinds of treatment had significant differences in the outcomes and complications (P < 0.05): the external fixation with limited internal fixation group got the best results. The number of anatomic reduction cases in the external fixation with limited internal fixation group (7 cases) and the distal tibia anatomical plate group (8 cases) was more than the plaster immobilization group (2 cases). According to the ankle score, 8 patients got an excellent result, 3 good and 1 poor in the limited internal fixation group ,which was better than those of distal tibia anatomical plate group (5 excellent, 4 good and 2 poor) and the plaster immobilization group (3 excellent, 4 good and 3 poor). The number of early and late complications in the external fixation with limited internal fixation group was more than those in the plaster immobilization group and the distal tibia anatomical plate group (P< 0.05). Treatment of external fixation with limited internal fixation in the treatment of Pilon fracture of Rüedi-Allgower type III is effective and safe.

  11. Use of external fixators for damage-control orthopaedics in natural disasters like the 2005 Pakistan earthquake.

    PubMed

    Awais, Syed; Saeed, Ayesha; Ch, Asad

    2014-08-01

    In the 2005 Pakistan earthquake, the great many injured with multiple fractures and open wounds provided a unique opportunity to practice damage-control orthopaedics. External fixators remain a time-tested tools for operating surgeons on such occasions. The locally manufactured, readily available Naseer-Awais (NA) external fixator filled such needs of this disaster with good outcome. This is a retrospective descriptive study of 19,700 patients that presented over seven months to the two centres established by the lead author (SMA) in Muzaffarabad and Mansehra just one night after the 2005 earthquake. A series of local and foreign orthopaedic surgeon teams operated in succession. The computerised patient data collection of 1,145 operations was retrospectively analysed. Of the 19,700 patients presenting to the SMA centres, 50% had limb injuries. Total fracture fixations were 1,145, of which 295 were external fixations: 185 were applied on the lower limb and 90 on upper limb, the majority were applied on tibia. External fixators are valuable damage-control tools in natural disasters and warfare injuries. The locally manufactured NA external fixator served the needs of the many limb injuries during the 2005 Pakistan earthquake.

  12. Hybrid external fixation in the treatment of tibial pilon fractures: A retrospective analysis of 162 fractures.

    PubMed

    Galante, Vito N; Vicenti, Giovanni; Corina, Gianfranco; Mori, Claudio; Abate, Antonella; Picca, Girolamo; Conserva, Vito; Speciale, Domenico; Scialpi, Lorenzo; Tartaglia, Nicola; Caiaffa, Vincenzo; Moretti, Biagio

    2016-10-01

    To determine the efficacy of hybrid external fixation in the treatment of tibial pilon fractures. Retrospective, multicentre study. Adult patients with tibial pilon fractures treated with hybrid external fixation. Fracture reduction with ligamentotaxis and fixation with XCaliber hybrid external fixator. Fracture union, complications, functional outcome (Mazur Ankle Score). Union was obtained in 159 fractures at an average of 125days; there were three delayed unions and three non-unions. The most frequent complication was superficial pin-track infections (48), all of which responded to local wound care and antibiotics. There were no deep infections and no DVT. Only one fracture had loss of reduction that required frame revision. The overall functional scores were 91 (excellent) for AO/OTA type A fractures, 89 (good) for type B fractures, and 75 (satisfactory) for type C fractures. Hybrid external fixation is an effective method of stabilising tibial pilon fractures, particularly those with marked comminution. The minimally-invasive technique and stable fixation enable early mobilisation, with good functional results and minimal complications. Level IV Case series. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Mechanics of external fixation device of spine: reducing the mounting stress

    NASA Astrophysics Data System (ADS)

    Piven, V. V.; Lyulin, S. V.; Kovalenko, P. I.; Mushtaeva, Yu A.

    2018-03-01

    During the installation of the external fixation device on the spine, there is an occurrence of mounting stress due to misalignment of the rod-screws. To determine the magnitude of the mounting stresses, mathematical dependencies are sometimes used. The proposed technical solution is to reduce stress in the external fixation device.

  14. External fixators in the treatment of midshaft clavicle non-unions: a systematic review.

    PubMed

    Barlow, Tim; Upadhyay, Piyush; Barlow, David

    2014-02-01

    Non- or mal-union of the clavicle is reported to occur in up to 15 % of conservatively treated fractures: the purpose of this systematic review is to examine the evidence for the use of external fixation in the treatment of clavicular non-union. We performed a search of MEDLINE and Embase, including all papers using external fixators for the treatment of clavicular non-union. Four papers satisfied our eligibility criteria: three case series and one case-control study. Level of evidence and quality assessment scoring were performed using published methods. Due to the heterogeneity of the study populations and interventions, no attempt at meta-analysis was made. External fixation in hypertrophic non-union of the clavicle, but not atrophic non-union, appears to be a reasonable treatment option. A pragmatic, multicentre, randomised controlled trial comparing external fixation and open reduction internal fixation in the treatment of hypertrophic non-union of the clavicle would be valuable.

  15. Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture

    PubMed Central

    Facaros, Zacharia; Ramanujam, Crystal L.; Stapleton, John J.

    2010-01-01

    The surgical management of ankle fractures among the diabetic population is associated with higher complication rates compared to the general population. Efforts toward development of better methods in prevention and treatment are continuously evolving for these injuries. The presence of peripheral neuropathy and the possible development of Charcot neuroarthropathy in this high risk patient population have stimulated much surgical interest to create more stable osseous constructs when open reduction of an ankle fracture/dislocation is required. The utilization of multiple syndesmotic screws (pro-syndesmotic screws) to further stabilize the ankle mortise has been reported by many foot and ankle surgeons. In addition, transarticular Steinmann pins have been described as an adjunct to traditional open reduction with internal fixation (ORIF) of the ankle to better stabilize the talus, thus minimizing risk of further displacement, malunion, and Charcot neuroarthropathy. The authors present a unique technique of ORIF with pro-syndesmotic screws and the application of a multi-plane circular external fixator for management of a neglected diabetic ankle fracture that prevented further deformity while allowing a weight-bearing status. This techniqu may be utilized for the management of complex diabetic ankle fractures that are prone to future complications and possible limb loss. PMID:22396812

  16. External fixation of tibial pilon fractures and fracture healing.

    PubMed

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  17. Biomechanical consequences of callus development in Hoffmann, Wagner, Orthofix and Ilizarov external fixators.

    PubMed

    Juan, J A; Prat, J; Vera, P; Hoyos, J V; Sánchez-Lacuesta, J; Peris, J L; Dejoz, R; Alepuz, R

    1992-09-01

    A theoretical analysis by a finite elements model (FEM) of some external fixators (Hoffmann, Wagner, Orthofix and Ilizarov) was carried out. This study considered a logarithmic progress of callus elastic characteristics. A standard configuration of each fixator was defined where design and application characteristics were modified. A comparison among standard configurations and influence of every variation was made with regard to displacement and load transmission at the fracture site. An experimental evaluation of standard configurations was performed with a testing machine. After experimental validation of the theoretical model was achieved, an application of physiological loads which act on a fractured limb during normal gait was analysed. A minimal contribution from an external fixator to the total rigidity of the bone-callus-fixator system was assessed when a callus showing minimum elastic characteristics had just been established. Insufficient rigidity from the fixation devices to assure an adequate immobilization during the early stages of fracture healing was verified. However, regardless of the external fixator, callus development was the overriding element for the rigidity of the fixator-bone system.

  18. Temporary and definitive external fixation of war injuries: use of a French dedicated fixator.

    PubMed

    Mathieu, Laurent; Ouattara, Naklan; Poichotte, Antoine; Saint-Macari, Erwan; Barbier, Olivier; Rongiéras, Fréderic; Rigal, Sylvain

    2014-08-01

    External fixation is the recommended stabilization method for both open and closed fractures of long bones in forward surgical hospitals. Specific combat surgical tactics are best performed using dedicated external fixators. The Percy Fx (Biomet) fixator was developed for this reason by the French Army Medical Service, and has been used in various theatres of operations for more than ten years. The tactics of Percy Fx (Biomet) fixator use were analysed in two different situations: for the treatment of French soldiers wounded on several battlefields and then evacuated to France and for the management of local nationals in forward medical treatment facilities in Afghanistan and Chad. Overall 48 externals fixators were implanted on 37 French casualties; 28 frames were temporary and converted to definitive rigid frames or internal fixation after medical evacuation. The 77 Afghan patients totalled 85 external fixators, including 13 temporary frames applied in Forward Surgical Teams (FSTs) prior to their arrival at the Kabul combat support hospital. All of the 47 Chadian patients were treated in a FST with primary definitive frames because of delayed surgical management and absence of higher level of care in Chad. Temporary frames were mostly used for French soldiers to facilitate strategic air medical evacuation following trauma damage control orthopaedic principles. Definitive rigid frames permitted achieving treatment of all types of war extremity injuries, even in poor conditions.

  19. Salvage of infected total knee fusion: the last option.

    PubMed

    Wiedel, Jerome D

    2002-11-01

    Currently the most common indication for an arthrodesis of the knee is a failed infected total knee prosthesis. Other causes of a failed total knee replacement that might necessitate a knee fusion include aseptic loosening, deficient extensor mechanism, poor soft tissues, and Charcot joint. Techniques available for achieving a knee fusion are external fixation and internal fixation methods. The external fixation compression devices have been the most widely used for knee fusion and have been successful until the indications for fusion changed to mostly failed prosthetic knee replacement. With failed total knee replacement, the problem of severe bone loss became an issue, and the external fixation compression devices, even including the biplane external fixators, have been the least successful method reported for gaining fusion. The Ilizarov technique has been shown to achieve rigid fixation despite this bone loss, and a review of reports are showing high fusion rates using this method. Internal fixation methods including plate fixation and intramedullary nails have had the best success in gaining fusion in the face of this bone loss and have replaced external fixation methods as the technique of choice for knee fusion when severe bone loss is present. A review of the literature and a discussion of different fusion techniques are presented including a discussion of the influence that infection has on the success of fusion.

  20. [Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    PubMed

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2017-11-07

    Objective: To make a systematic assessment of the Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Methods: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed. The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected. The included trials were screened out strictly based on the criterion of inclusion and exclusion. The quality of included trials was evaluated. RevMan 5.0 was used for data analysis. Results: Sixteen studies involving 1 268 patients were included. There were 618 patients with open reduction and internal fixation and 650 with external fixation. The results of meta-analysis indicated that there were statistically significant differences with regard to the complications postoperatively (infection( I (2)=0%, RR =0.27, 95% CI 0.16-0.45, Z =4.92, P <0.000 01) and total complications( I (2)=0%, RR =0.71, 95% CI 0.59-0.85, Z =3.65, P =0.000 3) ), DASH scores( I (2)=37%, MD =-5.67, 95% CI -8.31--3.04, Z =4.22, P <0.000 1) and volar tilt( I (2)=78%, MD =2.29, 95% CI 0.33-4.24, Z =2.30, P =0.02)( P <0.05) at the end of follow-up period were noted. There were no statistically significant differences observed between two approaches with respect to the clinical outcomes (grip strength, flexion, extension, pronation, supination, radial deviation and ulnar deviation) and radiographic outcome(radial length) at the end of follow-up period( P <0.05). Conclusion: Both open reduction and internal fixation and external fixation are effective treatment for unstable distal radius fractures. Compared with external fixation, open reduction and internal fixation provides reduced complications postoperatively, lower DASH scores and better restoration of volar tilt for treatment of distal radius fractures.

  1. Application of 3D printed customized external fixator in fracture reduction.

    PubMed

    Qiao, Feng; Li, Dichen; Jin, Zhongmin; Gao, Yongchang; Zhou, Tao; He, Jinlong; Cheng, Li

    2015-01-01

    Long bone fracture is common in traumatic osteopathic patients. Good reduction is beneficial for bone healing, preventing the complications such as delayed union, nonunion, malunion, but is hard to achieve. Repeated attempts during the surgery would increase the operation time, cause new damage to the fracture site and excessive exposure to radiation. Robotic and navigation techniques can help improve the reduction accuracy, however, the high cost and complexity of operation have limited their clinical application. We combined 3D printing with computer-assisted reduction technique to develop a customised external fixator with the function of fracture reduction. The original CT data obtained by scanning the fracture was imported to computer for reconstructing and reducing the 3D image of the fracture, based on which the external fixator (named as Q-Fixator) was designed and then fabricated by 3D printing techniques. The fracture reduction and fixation was achieved by connecting the pins inserted in the bones with the customised Q-Fixator. Experiments were conducted on three fracture models to demonstrate the reduction results. Good reduction results were obtained on all three fractured bone models, with an average rotation of 1.21°(± 0.24), angulation of 1.84°(± 0.28), and lateral displacement of 2.22 mm(± 0.62). A novel customised external fixator for long bone fracture reduction was readily developed using 3D printing technique. The customised external fixator had the advantages of easy manipulation, accurate reduction, minimally invasion and experience-independence. Future application of the customised external fixator can be extended to include the fixation function with stress adjustment and potentially optimise the fracture healing process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Hinged external fixation of the elbow.

    PubMed

    Chen, Neal C; Julka, Abhishek

    2010-08-01

    Hinged external fixation of the elbow provides the advantages of static fixation with the benefits of continued motion through the joint. Indications for the use of this method of fixation include traumatic instability, distraction interposition arthroplasty, instability after contracture release, and instability after excision of heterotopic ossification. Orthopedic surgeons should be familiar with hinged fixators and their application when faced with an unstable ulnohumeral joint. 2010 Elsevier Inc. All rights reserved.

  3. Internal Versus External Fixation of Charcot Midfoot Deformity Realignment.

    PubMed

    Lee, Daniel J; Schaffer, Joseph; Chen, Tien; Oh, Irvin

    2016-07-01

    Internal and external fixation techniques have been described for realignment and arthrodesis of Charcot midfoot deformity. There currently is no consensus on the optimal method of surgical reconstruction. This systematic review compared the clinical results of surgical realignment with internal and external fixation, specifically in regard to return to functional ambulation, ulcer occurrence, nonunion, extremity amputation, unplanned further surgery, deep infection, wound healing problems, peri- or intraoperative fractures, and total cases with any complication. A search of multiple databases for all relevant articles published from January 1, 1990, to March 22, 2014, was performed. A logistic regression model evaluated each of the outcomes and its association with the type of fixation method. The odds of returning to functional ambulation were 25% higher for internal fixation (odds ratio [OR], 1.259). Internal fixation had a 42% reduced rate of ulcer occurrence (OR, 0.578). External fixation was 8 times more likely to develop radiographic nonunion than internal fixation (OR, 8.2). Internal fixation resulted in a 1.5-fold increase in extremity amputation (OR, 1.488), a 2-fold increase in deep infection (OR, 2.068), a 3.4-fold increase in wound healing complications (OR, 3.405), and a 1.5-fold increase in the total number of cases experiencing any complication (OR, 1.525). This was associated with a 20% increase in the need for unplanned further surgery with internal fixation (OR, 1.221). Although internal fixation may decrease the risk of nonunion and increase return to functional ambulation, it had a higher rate of overall complications than external fixation for realignment and arthrodesis of Charcot midfoot deformity. [Orthopedics. 2016; 39(4):e595-e601.]. Copyright 2016, SLACK Incorporated.

  4. Pediatric and adolescent applications of the Taylor Spatial Frame.

    PubMed

    Paloski, Michael; Taylor, Benjamin C; Iobst, Christopher; Pugh, Kevin J

    2012-06-01

    Limb deformity can occur in the pediatric and adolescent populations from multiple etiologies: congenital, traumatic, posttraumatic sequelae, oncologic, and infection. Correcting these deformities is important for many reasons. Ilizarov popularized external fixation to accomplish this task. Taylor expanded on this by designing an external fixator in 1994 with 6 telescoping struts that can be sequentially manipulated to achieve multiaxial correction of deformity without the need for hinges or operative frame alterations. This frame can be used to correct deformities in children and has shown good anatomic correction with minimal morbidity. The nature of the construct and length of treatment affects psychosocial factors that the surgeon and family must be aware of prior to treatment. An understanding of applications of the Taylor Spatial Frame gives orthopedic surgeons an extra tool to correct simple and complex deformities in pediatric and adolescent patients. Copyright 2012, SLACK Incorporated.

  5. Treatment of femoral shaft fractures with monoaxial external fixation in polytrauma patients

    PubMed Central

    Testa, Gianluca; Aloj, Domenico; Ghirri, Alessandro; Petruccelli, Eraclite; Pavone, Vito; Massé, Alessandro

    2017-01-01

    Background: Femoral shaft fractures, typical in younger people, are often associated with polytrauma followed by traumatic shock. In these situations, despite intramedullary nailing being the treatment of choice, external fixation could be used as the definitive treatment. The aim of this study is to report evidence regarding definitive treatment of femoral shaft fractures with monoaxial external fixation. Methods: Between January 2006 and December 2015, 83 patients with 87 fractures were treated at the Department of Orthopaedics and Traumatology CTO of Turin, with a monoaxial external fixation device. Mean age at surgery, type of fracture, mean follow-up, time and modalities of treatment, non-weight bearing period, average healing, external fixation removal time, and complications were reported. Results: The average patient age was 31.43±15.19 years. In 37 cases (42.53%) the right femur was involved. 73 (83.91%) fractures were closed, and 14 (16.09%) were open. The average follow-up time was 61.07±21.86 weeks.  In 68 (78.16%) fractures the fixation was carried out in the first 24 hours, using a monoaxial external fixator. In the remaining 19 cases, the average delay was 6.80±4.54 days. Mean non-weight bearing time was 25.82±27.66 days (ranging from 0 to 120). The 87 fractures united at an average of 23.60±11.37 weeks (ranging from 13 to 102). The external fixator was removed after an average of 33.99±14.33 weeks (ranging from 20 to 120). Reported complications included 9.19% of delayed union, 1.15% of septic non-union, 5.75% of malunion, and 8.05% cases of loss of reduction. Conclusions: External fixation of femoral shaft fractures in polytrauma is an ideal method for definitive fracture stabilization, with minimal additional operative trauma and an acceptable complication rate. PMID:28928953

  6. Prevention of Thumb Web Space Contracture With Multiplanar External Fixation.

    PubMed

    Harper, Carl M; Iorio, Matthew L

    2016-09-01

    Thumb web space contracture following hand trauma can be disabling with numerous reconstructive procedures existing to correct the resultant deformity. Following marked soft tissue injury to the hand we utilized the Stryker Hoffmann II Micro External Fixator System to link the first and second metacarpals by a multiplanar system using 1.6 or 2.0 mm self-drilling half-pins and 3 mm carbon fiber connecting rods. This facilitated placement of the thumb in maximal palmar abduction as well as allowed adjustment of thumb position throughout the postoperative period. This technique was performed on 5 patients. Two patients were treated with a first web space external fixator for table saw injuries to the radial aspect of the hand. An additional 2 patients were treated with a first web space external fixator following metacarpophalangeal joint capsular release in the setting of thermal burns. A fifth patient underwent second ray amputation, trapeziectomy and trapezoidectomy for squamous cell carcinoma with subsequent stabilization with the external fixator. The external fixator was left in place until soft tissues were healed (average 5.5 wk). The patients were allowed to mobilize their hand in as much as the external fixator allowed, and no device-associated complications were noted. Thumb web space was preserved with passive and supple thumb circumduction and web space abduction/adduction in all patients at an average follow-up of 5 months. The average Quick Dash Score was 35±5 and the average Modern Activity Subjective Survey of 2007 was 30±8.

  7. Influence of fixation point of latissimus dorsi tendon transfer for irreparable rotator cuff tear on glenohumeral external rotation: A cadaver study.

    PubMed

    Bargoin, K; Boissard, M; Kany, J; Grimberg, J

    2016-12-01

    Latissimus dorsi tendon transfer is a surgical option for treating irreparable posterosuperior rotator cuff tears, notably when attempting to reconstruct active external rotation. We hypothesized that the positioning of the transfer's point of fixation would differ depending on the desired elbow-to-body external rotation or external rotation with the elbow abducted. Seven shoulders from four whole frozen cadavers were used. We created two systems to install the subject in a semi-seated position to allow external rotation elbow to body and the arm abducted 90°. Traction sutures were positioned on the latissimus dorsi muscle and a massive tear of the rotator cuff was created. We tested six different transfer positions. Muscle contraction of the latissimus dorsi was stimulated using 10-N and 20-N suspended weights. The point of fixation of the latissimus dorsi on the humeral head had an influence on the elbow-to-body external rotation and with 90° abduction (P<0.001). The fixation point for a maximum external rotation with the elbow to the body was the anterolateral position (P<0.016). The fixation point for a maximum external rotation at 90° abduction was the position centered on the infraspinatus footprint (P<0.078). The optimal point of fixation differs depending on whether external rotation is restored at 0° or 90° abduction. Fundamental study, anatomic study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  8. Minimally invasive treatment of tibial pilon fractures through arthroscopy and external fixator-assisted reduction.

    PubMed

    Luo, Huasong; Chen, Liaobin; Liu, Kebin; Peng, Songming; Zhang, Jien; Yi, Yang

    2016-01-01

    The aim of this study was to evaluate the clinical outcome of tibial pilon fractures treated with arthroscopy and assisted reduction with an external fixator. Thirteen patients with tibial pilon fractures underwent assisted reduction for limited lower internal fixation with an external fixator under arthroscopic guidance. The weight-bearing time was decided on the basis of repeat radiography of the tibia 3 months after surgery. Postoperative ankle function was evaluated according to the Mazur scoring system. Healing of fractures was achieved in all cases, with no complications such as severe infection, skin necrosis, or an exposed plate. There were 9 excellent, 2 good, and 2 poor outcomes, scored according to the Mazur system. The acceptance rate was 85%. Arthroscopy and external fixator-assisted reduction for the minimally invasive treatment of tibial pilon fractures not only produced less trauma but also protected the soft tissues and blood supply surrounding the fractures. External fixation could indirectly provide reduction and effective operative space for arthroscopic implantation, especially for AO type B fractures and partial AO type C1 fractures.

  9. Preventing Seal Leak During Negative Pressure Wound Therapy Near External Fixators: A Technical Tip.

    PubMed

    Mannino, Brian J; Pullen, Michael W; Gaines, Robert

    2017-03-01

    Negative pressure wound therapy is an effective tool for the treatment of open wounds. Occasionally these wounds are associated with injuries or procedures that require treatment with an external fixator. This article shows how a simple, inexpensive, and commercially available product can be used to prevent loss of suction around external fixator pins within the negative pressure wound treatment area.

  10. Evaluation of functional outcome of pilon fractures managed with limited internal fixation and external fixation: A prospective clinical study.

    PubMed

    Meena, Umesh Kumar; Bansal, Mahesh Chand; Behera, Prateek; Upadhyay, Rahul; Gothwal, Gyan Chand

    2017-11-01

    The management of pilon fractures is controversial primarily due to the high rate of complications irrespective of the mode of treatment. Limited internal fixation with external fixation is associated with minimal soft tissue handling. This may reduce the chances of wound dehiscence and infection. This study was designed to evaluate the functional and clinical outcomes in patients treated with limited internal fixation combined with external fixation in pilon fractures. This study was conducted as a prospective clinical study on 56 skeletally mature patients with closed fractures with poor skin condition, and with open grade 1 and grade 2 distal tibial intra-articular fractures. All patients were treated with combined limited internal fixation and ankle spanning external fixation. All fractures in this series united with an average time period of union of 18.3weeks (ranging from 13 weeks to 30 weeks). There was no non-union in any case. There was malunion in 4 cases, varus malunion (>5 degree) in 2 cases and recurvatum in another 2 cases). Excellent to good functional results were observed in 88% cases based on the modified Ovadia and Beals score. The mean ankle dorsiflexion and planter flexion movements were 10.2±5.3 degrees and 27.4±7.2 degrees respectively. infections occurred in 6 patients which included 4 pin tract infections and 2 superficial wound infection, all 6 healed after removal of pin tract and with oral antibiotics. The technique of combined external fixation with internal fixation is safe and effective management option for intra-articular distal tibial fractures.

  11. Comparison of 39 post-traumatic tibia bone transports performed with and without the use of an intramedullary rod: the long-term outcomes.

    PubMed

    Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian; Wiebking, Ulrich; Hankemeier, Stefan

    2011-09-01

    Bone transport can be performed with an external fixator alone or with the monorail technique which entails the combination of a fixator and an intramedullary nail. The purpose of this study was to compare the complication rates and long-term outcomes of these methods. Two groups of patients, the external fixator (n = 21) and the monorail group (n = 18), were compared. The average follow-up period was 7.9 ± 5.6 years and the mean defect length 8.3 ± 3.1 cm. Healing was achieved in 19 (90%) and 13 (72%) of the fixator and monorail patients, respectively. Six patients underwent amputations because of persistent infections (two in the fixator and four in the monorail group). The rate of deformities was significantly higher in the fixator group (p = 0.049). No statistically significant difference was found when comparing categories of the SF-36 test or the ability to work or do sports. The main advantages of the monorail method are reduction of the external fixation time and the lower rate of deformities. However, the authors recommend segmental transport with external fixator in patients with chronic infections.

  12. External fixation techniques for distal radius fractures.

    PubMed

    Capo, John T; Swan, Kenneth G; Tan, Virak

    2006-04-01

    Fractures of the distal radius are common injuries. Low-energy or high-energy mechanisms may be involved. Unstable distal radius fractures present a challenge to the treating orthopaedic surgeon. External fixation is a valuable instrument for fracture reduction and stabilization. Limited open incisions, early range of motion, and treatment of complex wounds are a few of the benefits of external fixation. Fixators may be spanning or nonbridging and may be used alone or in combination with other stabilization methods to obtain and maintain distal radius fracture reduction. Augmentation with percutaneous wires allows for optimal fracture stabilization with physiologic alignment of the wrist. Moderate distraction at the carpus does not induce postoperative stiffness. The distal radioulnar joint must be assessed and may need to be stabilized. Complications of external fixation are usually minor, but must be anticipated and treated early. Level V (expert opinion).

  13. External versus internal fixation for bicondylar tibial plateau fractures: systematic review and meta-analysis.

    PubMed

    Metcalfe, David; Hickson, Craig J; McKee, Lesley; Griffin, Xavier L

    2015-12-01

    It is uncertain whether external fixation or open reduction internal fixation (ORIF) is optimal for patients with bicondylar tibial plateau fractures. A systematic review using Ovid MEDLINE, Embase Classic, Embase, AMED, the Cochrane Library, Open Grey, Orthopaedic Proceedings, WHO International Clinical Trials Registry Platform, Current Controlled Trials, US National Institute for Health Trials Registry, and the Cochrane Central Register of Controlled Trials. The search was conducted on 3rd October 2014 and no language limits were applied. Inclusion criteria were all clinical study designs comparing external fixation with open reduction internal fixation of bicondylar tibial plateau fractures. Studies of only one treatment modality were excluded, as were those that included unicondylar tibial plateau fractures. Treatment effects from studies reporting dichotomous outcomes were summarised using odds ratios. Continuous outcomes were converted to standardized mean differences to assess the treatment effect, and inverse variance methods used to combine data. A fixed effect model was used for meta-analyses. Patients undergoing external fixation were more likely to have returned to preinjury activities by six and twelve months (P = 0.030) but not at 24 months follow-up. However, external fixation was complicated by a greater number of infections (OR 2.59, 95 % CI 1.25-5.36, P = 0.01). There were no statistically significant differences in the rates of deep infection, venous thromboembolism, compartment syndrome, or need for re-operation between the two groups. Although external fixation and ORIF are associated with different complication profiles, both are acceptable strategies for managing bicondylar tibial plateau fractures.

  14. Treatment of unstable distal radius fractures: non-invasive dynamic external fixator versus volar locking plate – functional and radiological outcome in a prospective case-controlled series

    PubMed Central

    Bajwa, Ali S.; Rammappa, Manju; Lee, Ling; Nanda, Rajesh

    2015-01-01

    Introduction: Distal radius fracture (DRF) is a common injury and various treatment modalities including open reduction and internal fixation (ORIF) with volar locking plate are available. More recently, a non-invasive external fixator has been used. Aims: To prospectively compare the use of a non-invasive external fixator with early dynamisation for DRF against ORIF with volar locking plate control group. Methods: Consecutive patients with closed DRF were included in a prospective case-controlled study. Patients were assigned to non-invasive external fixator or ORIF. Minimum follow-up was two years. Follow-up was at weeks 2, 4, 6, 8, 12, 26 and at one and two-year post-operatively. The outcome measures included demographic details, injury mechanism, AO fracture type, risk factors, body mass index (BMI), ulnar styloid fracture and dorsal comminution, radiographs, grip strength and DASH score. Results: Consecutive 50 patients were treated either with non-invasive external fixator (25/50) or with ORIF (25/50) and the mean age of the two groups was 53 years (SD 17.1) and 49 years (SD 19.5), respectively. Demographics were matched in two groups. In the non-invasive external fixator group, there were 10 AO Type-A, 5 Type-B and 10 Type-C fractures. The ORIF group included 8 Type-A, 6 Type-B and 11 Type-C fractures. The mean DASH score at three-months and one-year post-injury in non-invasive fixator group was 12.2 (SD 3.1) and 3.5 (SD 0.7), respectively, significantly greater than those of ORIF group 14.5 (SD 5.6) and 11.2 (SD 4.4), respectively (p < 0.05). Conclusion: DRF treated with non-invasive external fixator can give functional results superior to ORIF at three-months and the trend is maintained at one and two-year post-operatively. PMID:27163089

  15. Diluted povidone-iodine versus saline for dressing metal-skin interfaces in external fixation.

    PubMed

    Chan, C K; Saw, A; Kwan, M K; Karina, R

    2009-04-01

    To compare infection rates associated with 2 dressing solutions for metal-skin interfaces. 60 patients who underwent distraction osteogenesis with external fixators were equally randomised into 2 dressing solution groups (diluted povidone-iodine vs. saline). Fixations were attained using either rigid stainless steel 5-mm diameter half pins or smooth stainless steel 1.8-mm diameter wires. Half-pin fixation had one metal-skin interface, whereas wire fixation had 2 interfaces. Patients were followed up every 2 weeks for 6 months. Of all 788 metal-skin interfaces, 143 (18%) were infected: 72 (19%) of 371 in the diluted povidone-iodine group and 71 (17%) of 417 in the saline group. Dressing solution and patient age did not significantly affect infection rates. Half-pin fixation was more likely to become infected than wire fixation (25% vs 15%). Saline is as effective as diluted povidone-iodine as a dressing solution for metal-skin interfaces of external fixators. Saline is recommended in view of its easy availability and lower costs.

  16. Femoral Reconstruction Using External Fixation

    PubMed Central

    Palatnik, Yevgeniy; Rozbruch, S. Robert

    2011-01-01

    Background. The use of an external fixator for the purpose of distraction osteogenesis has been applied to a wide range of orthopedic problems caused by such diverse etiologies as congenital disease, metabolic conditions, infections, traumatic injuries, and congenital short stature. The purpose of this study was to analyze our experience of utilizing this method in patients undergoing a variety of orthopedic procedures of the femur. Methods. We retrospectively reviewed our experience of using external fixation for femoral reconstruction. Three subgroups were defined based on the primary reconstruction goal lengthening, deformity correction, and repair of nonunion/bone defect. Factors such as leg length discrepancy (LLD), limb alignment, and external fixation time and complications were evaluated for the entire group and the 3 subgroups. Results. There was substantial improvement in the overall LLD, femoral length discrepancy, and limb alignment as measured by mechanical axis deviation (MAD) and lateral distal femoral angle (LDFA) for the entire group as well as the subgroups. Conclusions. The Ilizarov external fixator allows for decreased surgical exposure and preservation of blood supply to bone, avoidance of bone grafting and internal fixation, and simultaneous lengthening and deformity correction, making it a very useful technique for femoral reconstruction. PMID:21991425

  17. External fixation for severe open fractures of the humerus caused by missiles.

    PubMed

    Zinman, C; Norman, D; Hamoud, K; Reis, N D

    1997-10-01

    To evaluate the use of external fixation of the humerus after missile injuries. Retrospective. University medical center. Twenty-six soldiers with twenty-six open Gustilo type III fractures. Immediate external fixation. Clinical, functional, social, and rehabilitation criteria were evaluated. Excellent in fourteen patients (61%), good in four (17%), fair in three (13%), and poor in two (9%). All fractures eventually healed. External fixation is the preferred initial treatment for stabilizing severe open missile fractures of the humerus. Its use, together with radical debridement of dead bone, has reduced the incidence of chronic infection and improved the prognosis of vascular repairs. As a result, the rate of morbidity and upper limb amputation has been reduced significantly, compared with our previous experience.

  18. [High tibial osteotomy--fixation by means of external fixation--indication, technique, complications (author's transl)].

    PubMed

    Klems, H

    1976-02-01

    High tibial osteotomy has proved its value in the treatment of gonarthrosis with or without axis deformity. The thrust of weight-bearing and other stresses is lessened on the degenerated tibial condyle and transferred to the more normal condyle. The stable fixation by means of external fixation allows early movement of the knee joint.-R-ferences to operative technique, indication, complications and after-treatment.

  19. A comparison of two techniques for knee arthrodesis: the custom made intramedullary Mayday nail versus a monoaxial external fixator.

    PubMed

    Yeoh, David; Goddard, Richard; Macnamara, Paul; Bowman, Nicholas; Miles, Kim; East, Debra; Butler-Manuel, Adrian

    2008-08-01

    The most common indication for knee arthrodesis is pain and instability in an unreconstructable knee following an infected knee arthroplasty. In this study, we compare the use of the Mayday arthrodesis nail (Orthodynamics, Christchurch, UK) versus external fixation, Orthofix (Berkshire UK) and Stryker Hoffman II (County Cork, Ireland). All patients in this study underwent arthrodesis between 1995 and 2006 at Conquest Hospital, Hastings. In group A, 11 patients underwent arthrodesis with a Mayday nail. In all cases, the indications were infected total knee replacements (TKR). Three of these patients previously had failed attempts at arthrodesis with external fixation devices. In group B, seven patients underwent arthrodesis using external fixation. In six patients, the indication was infected TKRs. Results were reviewed retrospectively, with union assessed both clinically and radiologically. The mean inpatient stay for the Mayday nail group was 23 days (range 8-45 days) compared with 76 days (range 34-122) for the external fixation group (p<0.01, CI 95). Ten patients in group A went on to confirmed primary arthrodesis. One patient underwent revision arthrodesis with a Mayday nail and subsequently united. In group B only two patients achieved union. The rate of union was significantly greater in the Mayday nail group than the external fixation group (91% vs 29%, p<0.01). Of those patients that achieved union, there was no difference in the time to fusion between groups. Our study supported the existing literature and found that the Mayday nail appeared more effective than monoaxial external fixators for arthrodesis in the management of infected total knee replacements.

  20. [Surgical treatment of tibial nonunion after wounding by high velocity missile and external fixators: a case report].

    PubMed

    Golubović, Ivan; Vukašinović, Zoran; Stojiljković, Predrag; Golubović, Zoran; Stojiljković, Danilo; Radovanović, Zoran; Ilić, Nenad; Najman, Stevo; Višnjić, Aleksandar; Arsić, Stojanka

    2012-01-01

    The missiles of modern firearms can cause severe fractures of the extremity. High velocity missile fractures of the tibia are characterized by massive tissue destruction and primary contamination with polymorphic bacteria. Treatment of these fractures is often complicated by delayed healing, poor position healing, nonhealing and bone tissue infection. We present the management of tibial nonunion after wounding by high velocity missile and primary treatment by external fixation in a 25-year-old patient. The patient was primarily treated with external fixation and reconstructive operations of the soft tissue without union of the fracture. Seven months after injury we placed a compression-distraction external fixator type Mitkovic and started with compression and distraction in the fracture focus after osteotomy of the fibula and autospongioplasty. We recorded satisfactory fracture healing and good functional outcome. Contamination and devitalization of the soft-tissue envelope increase the risk of infection and nonunion in fractures after wounding by high velocity missile. The use of the compression-distraction external fixator type Mitkovic may be an effective method in nonunions of the tibia after this kind of injury.

  1. Long-bone fractures in llamas and alpacas: 28 cases (1998–2008)

    PubMed Central

    Knafo, S. Emmanuelle; Getman, Liberty M.; Richardson, Dean W.; Fecteau, Marie-Eve

    2012-01-01

    Treatment and outcome of camelids with long-bone fractures are described. Medical records (1998–2008) of camelids (n = 28) with long-bone fractures were reviewed for signalment, time to presentation, fracture type, method of repair, duration of hospitalization, and post-operative complications. Follow-up information was obtained via telephone interviews with owners. Mean age and weight at presentation were 3.4 years and 56.3 kg, respectively. Twenty-six fractures were treated with internal fixation (n = 11), external fixation (n = 10), combination of internal and external fixation (n = 3), amputation (n = 1), and external fixation followed by amputation (n = 1). Long-term follow-up information was obtained for 19 of the 26 animals. The post-operative complication rate was 23% and owner satisfaction was high. Animals with open fractures were more likely to experience complications. Internal fixation was associated with superior alignment and outcome. Internal fixation techniques should be recommended for camelids. PMID:23277645

  2. Long-bone fractures in llamas and alpacas: 28 cases (1998-2008).

    PubMed

    Knafo, S Emmanuelle; Getman, Liberty M; Richardson, Dean W; Fecteau, Marie-Eve

    2012-07-01

    Treatment and outcome of camelids with long-bone fractures are described. Medical records (1998-2008) of camelids (n = 28) with long-bone fractures were reviewed for signalment, time to presentation, fracture type, method of repair, duration of hospitalization, and post-operative complications. Follow-up information was obtained via telephone interviews with owners. Mean age and weight at presentation were 3.4 years and 56.3 kg, respectively. Twenty-six fractures were treated with internal fixation (n = 11), external fixation (n = 10), combination of internal and external fixation (n = 3), amputation (n = 1), and external fixation followed by amputation (n = 1). Long-term follow-up information was obtained for 19 of the 26 animals. The post-operative complication rate was 23% and owner satisfaction was high. Animals with open fractures were more likely to experience complications. Internal fixation was associated with superior alignment and outcome. Internal fixation techniques should be recommended for camelids.

  3. Does pediatric body mass index affect surgical outcomes of lower-extremity external fixation?

    PubMed

    Fedorak, Graham T; Cuomo, Anna V; Otsuka, Norman Y

    2015-06-01

    Obese patients are highly prevalent in the pediatric orthopaedic surgeon's practice and obesity is an increasing issue in the United States. Increased body mass index (BMI) has been associated with increased complications in pediatric orthopaedic patients, but no study has looked specifically at external fixation. The purpose of this study was to determine whether obesity is a risk factor for increased complications in lower-extremity procedures requiring external fixation. A retrospective chart review was conducted of pediatric patients who underwent external fixation as definitive operative treatment for any condition at a tertiary care hospital over a 15-year period. Patients were grouped into normal weight, overweight, and obese based on Centers for Disease Control definitions. All orthopaedic complications were recorded. A total of 208 patients with a mean age of 11.2 years were identified. Ninety-four children were obese at the 95th percentile BMI or higher, 22 were overweight and 93 were normal weight. External fixation was applied to the tibia in 82 cases, to the femur in 77 and to both in 49. Mean duration of fixation was 160 days (range, 31 to 570 d) and patients were followed for a mean of 3.9 years (range, 1.0 to 12.0 y). There was no statistically significant difference in the rate of complications between the 3 groups (P=0.61). In the obese group complications occurred in 68.1% versus 66.7% in the overweight group and 61.3% in normal weight. In the setting of external fixator use for lower-extremity pathology in pediatric patients, there is no association between an increase in complications and obesity as defined by BMI. Complication rates are high when external fixation is utilized for the lower extremity, however, patients and families should not be counseled that increased BMI will add to the burden of orthopaedic complications in this situation. Level II-prognostic.

  4. An Overview of Internal and External Fixation Methods for the Diabetic Charcot Foot and Ankle.

    PubMed

    Ramanujam, Crystal L; Zgonis, Thomas

    2017-01-01

    Diabetic Charcot neuroarthropathy (DCN) of the foot and ankle is a challenging disease with regard to clinical presentation, pathogenesis, and prognosis. Its surgical management is equally difficult to interpret based on the wide array of options available. In the presence of an ulceration or concomitant osteomyelitis, internal fixation by means of screws, plates, or intramedullary nailing needs to be avoided when feasible. External fixation becomes a great surgical tool when managing DCN with concomitant osteomyelitis. This article describes internal and external fixation methods along with available literature to enlighten surgeons faced with treating this complex condition. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. External fixation is more suitable for intra-articular fractures of the distal radius in elderly patients

    PubMed Central

    Ma, Chuang; Deng, Qiang; Pu, Hongwei; Cheng, Xinchun; Kan, Yuhua; Yang, Jing; Yusufu, Aihemaitijiang; Cao, Li

    2016-01-01

    The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after 1 week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P=0.001), supination, (P=0.047) and extension (P=0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at 1 year. The plating group had a greater occurrence of wound infection (P=0.043), tendonitis, (P=0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the “gross motor” category (walking upstairs, bending over, walking 500 yards; P=0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after 1 year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries. PMID:27408765

  6. A theoretical analysis and finite element simulation of fixator-bone system stiffness on healing progression.

    PubMed

    Li, Jianfeng; Zhao, Xia; Hu, Xiaojie; Tao, Chunjing; Ji, Run

    2018-03-01

    The unilateral external fixator has become a quick and easy application for fracture stabilization of the extremities; the main value for evaluation of mechanical stability of the external fixator is stiffness. The stiffness property of the external fixator affects the local biomechanical environment of fractured bone. In this study, a theoretical model with changing Young's modulus of the callus is established by using the Castigliano's theory, investigating compression stiffness, torsional stiffness and bending stiffness of the fixator-bone system during the healing process. The effects of pin deviation angle on three stiffness methods are also investigated. In addition, finite element simulation is discussed regarding the stress distribution between the fixator and bone. The results reveal the three stiffness evaluation methods are similar for the fixator-bone system. Finite element simulation shows that with increased healing time, the transmission of the load between the fixator and bone are different. In addition, the finite element analyses verify the conclusions obtained from the theoretical model. This work helps orthopedic doctors to monitor the progression of fracture healing and determine the appropriate time for removal of a fixation device and provide important theoretical methodology.

  7. Minimal internal fixation augmented by small wire transfixion frames for high-energy tibial plateau fractures.

    PubMed

    Katsenis, Dimitris; Athanasiou, Vasilis; Vasilis, Athanasiou; Megas, Panayiotis; Panayiotis, Megas; Tyllianakis, Minos; Minos, Tillianakis; Lambiris, Elias

    2005-04-01

    To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.

  8. Stress corrosion cracking of an aluminum alloy used in external fixation devices.

    PubMed

    Cartner, Jacob L; Haggard, Warren O; Ong, Joo L; Bumgardner, Joel D

    2008-08-01

    Treatment for compound and/or comminuted fractures is frequently accomplished via external fixation. To achieve stability, the compositions of external fixators generally include aluminum alloy components due to their high strength-to-weight ratios. These alloys are particularly susceptible to corrosion in chloride environments. There have been several clinical cases of fixator failure in which corrosion was cited as a potential mechanism. The aim of this study was to evaluate the effects of physiological environments on the corrosion susceptibility of aluminum 7075-T6, since it is used in orthopedic external fixation devices. Electrochemical corrosion curves and alternate immersion stress corrosion cracking tests indicated aluminum 7075-T6 is susceptible to corrosive attack when placed in physiological environments. Pit initiated stress corrosion cracking was the primary form of alloy corrosion, and subsequent fracture, in this study. Anodization of the alloy provided a protective layer, but also caused a decrease in passivity ranges. These data suggest that once the anodization layer is disrupted, accelerated corrosion processes occur. (c) 2007 Wiley Periodicals, Inc.

  9. Limb salvage in Charcot foot and ankle osteomyelitis: combined use single stage/double stage of arthrodesis and external fixation.

    PubMed

    Dalla Paola, Luca; Brocco, Enrico; Ceccacci, Tanja; Ninkovic, Sasa; Sorgentone, Sara; Marinescu, Maria Grazia; Volpe, Antonio

    2009-11-01

    Charcot neuroarthropathy of the foot/ankle is a devastating complication of diabetes. Along with neuroarthropathy, osteomyelitis can occur which can result in amputation. This prospective study evaluated a limb salvage procedure as an alternative to amputation through surgical treatment of osteomyelitis of the midfoot or the ankle and stabilization with external fixation. Forty-five patients with Charcot arthropathy and osteomyelitis underwent debridement and attempted fusion with an external fixator. Chart and radiograph review was performed to assess the success of the fusion and eradication of infection. Out of 45 patients, 39 patients healed using emergent surgery to drain an acute manifestation of the infection while maintaining the fixation for an average of 25.7 weeks. Two patients were treated with intramedullary nail in a subsequent surgical procedure. In four patients, the infection could not be controlled, therefore a major amputation was carried out. For select patients, external fixation proved to be a reasonable alternative to below-knee amputation.

  10. Advantages of the Ilizarov external fixation in the management of intra-articular fractures of the distal tibia

    PubMed Central

    Vasiliadis, Elias S; Grivas, Theodoros B; Psarakis, Spyridon A; Papavasileiou, Evangelos; Kaspiris, Angelos; Triantafyllopoulos, Georgios

    2009-01-01

    Background Treatment of distal tibial intra-articular fractures is challenging due to the difficulties in achieving anatomical reduction of the articular surface and the instability which may occur due to ligamentous and soft tissue injury. The purpose of this study is to present an algorithm in the application of external fixation in the management of intra-articular fractures of the distal tibia either from axial compression or from torsional forces. Materials and methods Thirty two patients with intra-articular fractures of the distal tibia have been studied. Based on the mechanism of injury they were divided into two groups. Group I includes 17 fractures due to axial compression and group II 15 fractures due to torsional force. An Ilizarov external fixation was used in 15 patients (11 of group I and 4 of group II). In 17 cases (6 of group I and 11 of group II) a unilateral hinged external fixator was used. In 7 out of 17 fractures of group I an additional fixation of the fibula was performed. Results All fractures were healed. The mean time of removal of the external fixator was 11 weeks for group I and 10 weeks for group II. In group I, 5 patients had radiological osteoarthritic lesions (grade III and IV) but only 2 were symptomatic. Delayed union occurred in 3 patients of group I with fixed fibula. Other complications included one patient of group II with subluxation of the ankle joint after removal of the hinged external fixator, in 2 patients reduction found to be insufficient during the postoperative follow up and were revised and 6 patients had a residual pain. The range of ankle joint motion was larger in group II. Conclusion Intra-articular fractures of the distal tibia due to axial compression are usually complicated with cartilaginous problems and are requiring anatomical reduction of the articular surface. Fractures due to torsional forces are complicated with ankle instability and reduction should be augmented with ligament repair, in order to restore normal movement of talus against the mortise. Both Ilizarov and hinged external fixators are unable to restore ligamentous stability. External fixation is recommended only for fractures of the ankle joint caused by axial compression because it is biomechanically superior and has a lower complication rate. PMID:19754962

  11. [Treatment of pediatric distal femur fractures by external fixator combined with limited internal fixation].

    PubMed

    Wei, Sheng-wang; Shi, Zhan-ying; Hu, Ju-zheng; Wu, Hao

    2016-03-01

    To discuss the clinical effects of external fixator combined with limited internal fixation in the treatment of pediatric distal femur fractures. From January 2008 to June 2014, 17 children of distal femur fractures were treated by external fixator combined with limited internal fixation. There were 12 males and 5 females, aged from 6 to 13 years old with an average of 10.2 years, ranged in the course of disease from 1 h to 2 d. Preoperative diagnoses were confirmed by X-ray films in all children. There were 11 patients with supracondylar fracture , and 6 patients with intercondylar comminuted fracture. According to AO/ASIF classification, 9 fractures were type A1, 5 cases were type A2,and 3 cases were type C1. The intraoperative and postoperative complications, postoperative radiological examination, lower limbs length and motion of knee joints were observed. Knee joint function was assessed by KSS score. All the patients were followed up from 6 to 38 months with an average of 24.4 months. No nerve or blood vessel injury was found. One case complicated with the external fixation loosening, 2 cases with the infection of pin hole and 3 cases with the leg length discrepancy. Knee joint mobility and length measurement (compared with the contralateral), the average limited inflexion was 10 degrees (0 degrees to 20 degrees), the average limited straight was 4 degrees (0 degrees to 10), the average varus or valgus angle was 3 degrees (0 degrees to 5 degrees). KSS of the injured side was (96.4 +/- 5.0) points at final follow-up, 16 cases got excellent results and 1 good. All fractures obtained healing and no epiphyseal closed early was found. External fixator combined with limited internal fixation has advantages of simple operation, reliable fixation, early functional exercise in treating pediatric distal femurs fractures.

  12. Treatment of inherently unstable open or infected fractures by open wound management and external skeletal fixation.

    PubMed

    Ness, M G

    2006-02-01

    To assess the use of external skeletal fixation with open wound management for the treatment of inherently unstable open or infected fractures in dogs. A retrospective review of 10 cases. Fracture stabilisation and wound management required only a single anaesthetic, and despite the challenging nature of these injuries, the final outcome was acceptable or good in every case. However, minor complications associated with the fixator pins were quite common, and two dogs developed complications which required additional surgery. Open management of wounds, even when bone was exposed, proved to be an effective technique, and external skeletal fixators were usually effective at maintaining stability throughout an inevitably extended fracture healing period.

  13. Treatment of war injuries of the shoulder with external fixators.

    PubMed

    Davila, Slavko; Mikulić, Danko; Davila, Neda Jarza; Popović, Ljiljana; Zupancić, Bozidar

    2005-05-01

    In this retrospective study, 18 patients with war injuries of the shoulder were reviewed to evaluate the technical problems associated with external fixation and to analyze the incidence of infection and late functional results. The average patient age was 28.5 years. All patients were male. Thirteen patients had explosive wounds, whereas five wounds were caused by gunshot missiles. All injuries were extensive in terms of bone and soft tissue defects. Six patients presented with complex injuries involving neurovascular structures. Sixteen patients were treated with external fixation. Application of the proximal pins of the external fixator through the humeral head was possible in eight patients, the scapula served as the site of proximal fixation in four patients, only the clavicle was available for placement of pins in two patients, and both the scapula and the clavicle had to be pinned to achieve proximal stabilization in two patients. In two patients, fixation was not possible and early amputation was performed. Infection was eventually eradicated in all patients, allowing for adequate soft tissue coverage of the wounds. Analysis of functional results at an average of 6 years after the injury showed a considerable degree of functional deficit in most patients.

  14. Radial nerve injury following elbow external fixator: report of three cases and literature review.

    PubMed

    Trigo, Luis; Sarasquete, Juan; Noguera, Laura; Proubasta, Ignacio; Lamas, Claudia

    2017-07-01

    Radial nerve palsy is a rare but serious complication following elbow external fixation. Only 11 cases have been reported in the literature to date, but the incidence may be underreported. We present three new cases of this complication. We analyzed the three cases of radial palsy seen in our center following the application of an external fixator as treatment for complex elbow injuries. Mean patient age at surgery was 50 years. Two patients were female and one was male. In the three cases, the initial lesion was a posterior elbow dislocation, associated with a fracture of the radial shaft in one and a radial head fracture and coronoid fracture, respectively, in the other two. Due to persistent elbow instability, an external fixator was applied in all three cases. The fixator pins were introduced percutaneously in two cases and under direct vision in an open manner in the third case. Radial palsy was noted immediately postoperatively in all cases. It was permanent in two cases and temporary in the third. Radial nerve palsy after placement of an external elbow fixator was resolved in only 1 of our 3 cases and in 6 of the 11 cases in the literature to date. Although the event is rare, these alarming results highlight the need for recommendations to avoid this complication.

  15. Dynamic Distraction External Fixation for Contracture of the Metacarpophalangeal Joint.

    PubMed

    Seigerman, Daniel A; Tan, Virak

    2015-12-01

    Metacarpophalangeal (MP) joint contractures are common after traumatic injury, and can be difficult to manage. After surgical capsulectomy, it remains challenging to maintain motion that was obtained at the time of surgery. Our group uses a novel, prefabricated digital external fixator to provide both distraction, and motion therapy across the MP joint after surgical treatment of MP contracture. The purpose of this technique is to demonstrate the effectiveness of an adjunctive dynamic distraction external fixator for the maintenance of joint motion after surgical treatment of MP contractures of the border digits.

  16. Radiological evaluation of ankle arthrodesis with Ilizarov fixation compared to internal fixation.

    PubMed

    Morasiewicz, Piotr; Dejnek, Maciej; Urbański, Wiktor; Dragan, Szymon Łukasz; Kulej, Mirosław; Dragan, Szymon Feliks

    2017-07-01

    We asked whether the type of ankle joint arthrodesis stabilization will affect: (1) rate of union, (2) rate of adjacted-joint arthritis, (3) malalignment of the ankle joint. We retrospectively radiological studied 62 patients who underwent ankle arthrodesis with Ilizarov external fixator stabilization (group 1,n=29) or internal stabilization (group 2,n=33) from 2006 to 2015. Radiologic outcomes were mesure by: (1) rate of union, (2) rate of adjacent-joint arthritis, (3) malalignment of the ankle joint. The Levene's test,Mann-Whitney U test and Students t-test were used to the statistical analyses. Ankle fusion was achieved in 100% of patients treated with external fixation and in 88% with internal stabilization. Desired frontal plane alignment was achieved in 100% of patients with external fixation and 76% with internal stabilization. Desired sagittal plane alignment was achieved in 100% of external fixation and 85% of internal stabilization. A total of 14 (48.3%) patients from group 1 showed a radiographic evidence of pre-existing adjacent-joint OA. The radiographic evidence of pre-existing adjacent-joint OA was also found in 27(81.8%) subjects from group 2. Alterations of adjacent joints were also found on postoperative radiograms of 19 (65.5%) patients subjected to Ilizarov fixation and in all 33 patients from group 2. Ilizarov fixation of ankle arthrodesis is associated with lower prevalence of adjacent-joint OA and ankle joint misalignment,and with higher fusion rates than after internal fixation.Although achieving a complex ankle fusion is generally challenging,radiological outcomes after fixation with the Ilizarov apparatus are better than after internal stabilization. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. [Comparison study on locking compress plate external fixator and standard external fixator for treatment of tibial open fractures].

    PubMed

    Wu, Gang; Luo, Xiaozhong; Tan, Lun; Lin, Xu; Wu, Chao; Guo, Yong; Zhong, Zewei

    2013-11-01

    To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P > 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P > 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (Chi(2)=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 versus 13.0% and 0 versus 8.7%, P > 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (Chi(2)=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P < 0.05). The LCP external fixator can obtain reliable fixation in treating tibial open fracture, and has good patients' compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.

  18. [Pedicle flap transfer combined with external fixator to treat leg open fracture with soft tissue defect].

    PubMed

    Luo, Zhongchun; Lou, Hua; Jiang, Junwei; Song, Chunlin; Gong, Min; Wang, Yongcai

    2008-08-01

    To investigate the clinical results of treating leg open fracture with soft tissue defect by pedicle flap transfer in combination with external fixator. From May 2004 to June 2007, 12 cases of leg open fracture with soft tissue defect, 9 males and 3 females aged 18-75 years, were treated. Among them, 8 cases were caused by traffic accidents, 2 crush, 1 falling and 1 mechanical accident. According to the Gustilo Classification, there were 2 cases of type II, 5 of type IIIA and 5 of type IIIB. There were 2 cases of upper-tibia fracture, 3 of middle-tibia and 7 of middle-lower. The sizes of soft tissue defect ranged from 5 cm x 3 cm to 22 cm x 10 cm.The sizes of exposed bone ranged from 3 cm x 2 cm to 6 cm x 3 cm. The course of the disease was 1-12 hours. Fracture fixation was reached by external fixators or external fixators and limited internal fixation with Kirschner wire. The wounds with exposed tendons and bones were repaired by ipsilateral local rotation flap, sural neurocutaneous flap and saphenous nerve flap. The size of selected flap ranged from 5 cm x 4 cm to 18 cm x 12 cm. Granulation wounds were repaired by skin grafting or direct suture. All patients were followed up for 6 months to 2 years. All patients survived, among whom 2 with the wound edge infection and 1 with the distal necrosis were cured by changing the dressing, 8 with pin hole infection were treated by taking out the external fixator, 1 with nonunion received fracture healing after bone graft in comminuted fracture of lower tibia, 2 suffered delayed union in middle-lower tibia fracture. The ROM of ankle in 3 cases was mildly poor with surpass-joint fixation, with plantar extension of 0-10 degrees and plantar flexion of 10-30 degrees, while the others had plantar extension of 10-20 degrees and plantar flexion of 30-50 degrees. The method of pedicle flap transfer combined with external fixator is safe and effective for the leg open fracture with soft tissue defect.

  19. External fixation versus open reduction with locked volar plating for geriatric distal radius fractures.

    PubMed

    Lee, Daniel J; Elfar, John C

    2014-09-01

    The optimal management of displaced dorsal radius fractures (DRFs) in older patients remains an issue of debate. Bridging external fixation is a well-accepted treatment modality for severely comminuted DRFs, while open reduction and internal fixation with locked volar plating has emerged as a promising alternative in recent years. The current body of randomized trials supports the trend toward locked volar plating, as it allows for quicker improvement in subjective and functional outcomes. There is no clear evidence to suggest that one technique carries significantly less complications than the other. Locked volar plating should be considered in patients for whom an accelerated functional recovery would be advantageous. Otherwise, both external fixation and locked volar plating provide good long-term clinical outcomes.

  20. [Clinical application of percutaneous iliosacral screws combined with pubic ramus screws in Tile B pelvic fracture].

    PubMed

    Xu, Qi-Fei; Lin, Kui-Ran; Zhao, Dai-Jie; Zhang, Song-Qin; Feng, Sheng-Kai; Li, Chen

    2017-03-25

    To investigate the application and effect of minimally invasive percutaneous anterior pelvic pubic ramus screw fixation in Tile B fractures. A retrospective review was conducted on 56 patients with posterior pelvic ring injury combined with fractures of anterior pubic and ischiadic ramus treated between May 2010 and August 2015, including 31 males and 25 females with an average age of 36.8 years old ranging from 35 to 65 years old. Based on the Tile classification, there were 13 cases of Tile B1 type, 28 cases of Tile B2 type and 15 cases of Tile B3 type. Among them, 26 patients were treated with sacroiliac screws combined with external fixation (external fixator group) and the other 30 patients underwent sacroiliac screw fixation combined with anterior screw fixation (pubic ramus screw group). Postoperative complications, postoperative ambulation time, fracture healing, blood loss, Majeed pelvic function score and visual analogue scale(VAS) were compared between two groups. Fifty-four patients were followed up from 3 to 24 months with a mean of 12 months. There were no significant difference in the peri-operative bleeding and operation time between two groups( P >0.05). The postoperative activity time and fracture healing time of pubic ramus screw group were shorter than those of the external fixator group, the differences were statistically significant( P <0.05). The Majeed score, VAS score of pubic ramus screw group were higher than those of the external fixator group, the differences were statistically significant( P <0.05). The incidence of postoperative complications of pubic ramus screw was lower than that of the external fixator group, the difference was statistically significant ( P <0.05). Percutaneous iliosacral screws fixation combined with the pubic ramus screw is an effective and safty treatment method to the Tile B pelvic fracture. It has advantages of early ambulation, relief of the pain and few complications.

  1. Ilizarov bone transport versus fibular graft for reconstruction of tibial bone defects in children.

    PubMed

    Abdelkhalek, Mostafa; El-Alfy, Barakat; Ali, Ayman M

    2016-11-01

    The aim of this study was to compare the results of treatment of segmental tibial defects in the pediatric age group using an Ilizarov external fixator versus a nonvascularized fibular bone graft. This study included 24 patients (age range from 5.5 to 15 years) with tibial bone defects: 13 patients were treated with bone transport (BT) and 11 patients were treated with a nonvascularized fibular graft (FG). The outcome parameters were bone results (union, deformity, infection, leg-length discrepancy) and functional results: external fixation index and external fixation time. In group A (BT), one patient developed refracture at the regenerate site, whereas, in group B (FG), after removal of the external fixator, one of the FGs developed a stress fracture. The external fixator time in group A was 10.7 months (range 8-14.5) versus 7.8 months (range 4-11.5 months) in group B (FG). In group A (BT), one patient had a limb-length discrepancy (LLD), whereas, in group B (FG), three patients had LLD. The functional and bone results of the Ilizarov BT technique were excellent in 23.1 and 30.8%, good in 38.5 and 46.2, fair in 30.8 and 15.4, and poor in 7.6 and 7.6%, respectively. The poor functional result was related to the poor bone result because of prolonged external fixator time resulting in significant pain, limited ankle motion, whereas the functional and bone results of fibular grafting were excellent in 9.1 and 18.2%, good in 63.6 and 45.5%, fair in 18.2 and 27.2%, and poor in 9.1 and 9.1%, respectively. Segmental tibial defects can be effectively treated with both methods. The FG method provides satisfactory results, with early removal of the external fixator. However, it had a limitation in patients with severe infection and those with LLD. Also, it requires a long duration of limb bracing until adequate hypertrophy of the graft. The Ilizarov method has the advantages of early weight bearing, treatment of postinfection bone defect in a one-stage surgery, and the possibility to treat the associated LLD. However, it has a long external fixation time.

  2. The Cost-Effectiveness of Surgical Fixation of Distal Radial Fractures: A Computer Model-Based Evaluation of Three Operative Modalities.

    PubMed

    Rajan, Prashant V; Qudsi, Rameez A; Dyer, George S M; Losina, Elena

    2018-02-07

    There is no consensus on the optimal fixation method for patients who require a surgical procedure for distal radial fractures. We used cost-effectiveness analyses to determine which of 3 modalities offers the best value: closed reduction and percutaneous pinning, open reduction and internal fixation, or external fixation. We developed a Markov model that projected short-term and long-term health benefits and costs in patients undergoing a surgical procedure for a distal radial fracture. Simulations began at the patient age of 50 years and were run over the patient's lifetime. The analysis was conducted from health-care payer and societal perspectives. We estimated transition probabilities and quality-of-life values from the literature and determined costs from Medicare reimbursement schedules in 2016 U.S. dollars. Suboptimal postoperative outcomes were determined by rates of reduction loss (4% for closed reduction and percutaneous pinning, 1% for open reduction and internal fixation, and 11% for external fixation) and rates of orthopaedic complications. Procedural costs were $7,638 for closed reduction and percutaneous pinning, $10,170 for open reduction and internal fixation, and $9,886 for external fixation. Outputs were total costs and quality-adjusted life-years (QALYs), discounted at 3% per year. We considered willingness-to-pay thresholds of $50,000 and $100,000. We conducted deterministic and probabilistic sensitivity analyses to evaluate the impact of data uncertainty. From the health-care payer perspective, closed reduction and percutaneous pinning dominated (i.e., produced greater QALYs at lower costs than) open reduction and internal fixation and dominated external fixation. From the societal perspective, the incremental cost-effectiveness ratio for closed reduction and percutaneous pinning compared with open reduction and internal fixation was $21,058 per QALY and external fixation was dominated. In probabilistic sensitivity analysis, open reduction and internal fixation was cost-effective roughly 50% of the time compared with roughly 45% for closed reduction and percutaneous pinning. When considering data uncertainty, there is only a 5% to 10% difference in the frequency of probability combinations that find open reduction and internal fixation to be more cost-effective. The current degree of uncertainty in the data produces difficulty in distinguishing either strategy as being more cost-effective overall and thus it may be left to surgeon and patient shared decision-making. Economic Level III. See Instructions for Authors for a complete description of levels of evidence.

  3. Arthrodesis of the knee following failed arthroplasty.

    PubMed

    Van Rensch, P J H; Van de Pol, G J; Goosen, J H M; Wymenga, A B; De Man, F H R

    2014-08-01

    Primary stability in arthrodesis of the knee can be achieved by external fixation, intramedullary nailing or plate fixation. Each method has different features and results. We present a practical algorithm for arthrodesis of the knee following a failed (infected) arthroplasty, based on our own results and a literature review. Between 2004 and 2010, patients were included with an indication for arthrodesis after failed (revision) arthroplasty of the knee. Patients were analyzed with respect to indication, fusion method and bone contact. End-point was solid fusion. Twenty-six arthrodeses were performed. Eighteen patients were treated because of an infected arthroplasty. In total, ten external fixators, ten intramedullary nails and six plate fixations were applied; solid fusion was achieved in 3/10, 8/10 and 3/6, respectively. There is no definite answer as to which method is superior in performing an arthrodesis of the knee. Intramedullary nailing achieved the best fusion rates, but was used most in cases without--or cured--infection. Our data and the contemporary literature suggest that external fixation can be abandoned as standard fusion method, but can be of use following persisting infection. The Ilizarov circular external fixator, however, seems to render high fusion rates. Good patient selection and appropriate individual treatment are the key to a successful arthrodesis. Based upon these findings, a practical algorithm was developed.

  4. External fixation of "intertrochanteric" fractures.

    PubMed

    Gani, Naseem Ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool

    2009-10-10

    In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with "intertrochanteric" fractures remain unsuita ble for open reduction and internal fixation.The aim of this study was to analyze the results of external fixation of "intertrochanteric" fractures in high-risk geriatric patients in a developing country.The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58-90 years) with "intertrochanteric" fractures, in whom external fixation was performed, are reported.Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients.This study demonstrated that external fixation of "intertrochantric" fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country.

  5. [Effectiveness comparison of flexible fixation and rigid fixation in treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis].

    PubMed

    Li, Yuewei; Zhang, Minghui; Li, Xiaorong; Chen, Xiaoyong; Deng, Jianlong

    2017-07-01

    To compare the effectiveness of flexible fixation and rigid fixation in the treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis. A retrospective analysis was made on the clinical data of 50 patients with ankle pronation-external rotation fractures and distal tibiofibular syndesmosis treated between January 2013 and December 2015. Suture-button fixation was used in 23 patients (flexible fixation group) and cortical screw fixation in 27 patients (rigid fixation group). There was no significant difference in age, gender, weight, side, fracture type, and time from trauma to surgery between 2 groups ( P >0.05). The operation time, medial clear space (MCS), tibiofibular clear space (TFCS), tibiofibular overlap (TFO), American Orthopaedic Foot and Ankle Society (AOFAS) score, and Foot and Ankle Disability Index (FADI) score were compared between 2 groups. The operation time was (83.0±9.1) minutes in the flexible fixation group and was (79.6±13.1) minutes in the rigid fixation group, showing no significant difference ( t =1.052, P =0.265). All patients achieved healing of incision by first intention. The patients were followed up 12-20 months (mean, 14 months). The X-ray films showed good healing of fracture in 2 groups. There was no screw fracture, delayed union or nounion. The fracture healing time was (12.1±2.5) months in the flexible fixation group and was (11.3±3.2) months in the rigid fixation group, showing no significant difference between 2 groups ( t =1.024, P =0.192). Reduction loss occurred after removal of screw in 2 cases of the rigid fixation group. At last follow-up, there was no significant difference in MCS, TFCS, TFO, AOFAS score and FADI score between 2 groups ( P >0.05). Suture-button fixation has similar effectiveness to screw fixation in ankle function and imaging findings, and flexible fixation has lower risk of reduction loss of distal tibiofibular syndesmosis than rigid fixation.

  6. A Meta-Analysis for Postoperative Complications in Tibial Plafond Fracture: Open Reduction and Internal Fixation Versus Limited Internal Fixation Combined With External Fixator.

    PubMed

    Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang

    2015-01-01

    The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. [Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures].

    PubMed

    Zhang, Jian; Lin, Xu; Zhong, Zeli; Wu, Chao; Tan, Lun

    2017-07-01

    To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups ( P >0.05). There was no significant difference in operation time and hospitalization stay between 2 groups ( P >0.05). But the intraoperative blood loss in group A was significantly less than that in group B ( P <0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B ( P <0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference ( χ 2 =0.055, P =0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups ( χ 2 =0.056, P =0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups ( t =-0.028, P =0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B ( P <0.05). The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

  8. [Indications for arthrodesis of the knee joint in modern orthopedics].

    PubMed

    Hart, R; Janecek, M; Bucek, P; Procházka, V; Visna, P

    2003-04-01

    Indication for arthrodesis of the knee joint is nowadays most frequently failure of a total endoprosthesis, usually septic. A less frequent indication is purulent gonitis, frequently after corticoid administration, the condition after a complicated intraarticular fracture with subsequent arthritis or oncological disease of the bones in the area of the knee joint. In the course of 2000 to 2002 at the authors' department 15 arthrodeses were implanted. In three cases the indication for arthrodesis was purulent gonitis, in three cases the condition after an open articular injury associated with infectious complications and in the remaining nine cases failure of an endoprosthesis of the knee, incl. seven caused by infection. The patients were three men and 12 women, mean age 64 years (30-75 years). For stabilization of the arthrodesis 9x external fixation was used, 5x plates and 1x intramedullary osteosynthesis. In all cases consolidation of the arthrodesis was achieved. In one case the external fixation had to be replaced by a system of two fixation devices and in one case correction of the axial position of the extremity was made. The presence of external fixation was perceived negatively in particular by female patients. Plate osteosynthesis and the use of external fixation devices are relatively quick, cheap and considerate methods of arthrodesis. External fixation must be used in acute virulent infections while plate osteosynthesis can be indicated in its absence. The characteristic of intramedullary fixation is similar, however special nails used for arthrodesis of the knee are several times more expensive than the previous types of stabilization. The advantage is the possibility to use a massive bone graft to fill the defect.

  9. Surgical correction of severe spinal deformities using a staged protocol of external and internal techniques.

    PubMed

    Prudnikova, Oksana G; Shchurova, Elena N

    2018-02-01

    There is high risk of neurologic complications in one-stage management of severe rigid spinal deformities in adolescents. Therefore, gradual spine stretching variants are applied. One of them is the use of external transpedicular fixation. Our aim was to retrospectively study the outcomes of gradual correction with an apparatus for external transpedicular fixation followed by internal fixation used for high-grade kyphoscoliosis in adolescents. Twenty five patients were reviewed (mean age, 15.1 ± 0.4 years). Correction was performed in two stages: 1) gradual controlled correction with the apparatus for external transpedicular fixation; and 2) internal posterior transpedicular fixation. Rigid deformities in eight patients required discapophysectomy. Clinical and radiographic study of the outcomes was conducted immediately after treatment and at a mean long-term period of 3.8 ± 0.4 years. Pain was evaluated using the visual analogue scale (VAS, 10 points). The Oswestry questionnaire (ODI scale) was used for functional assessment. Deformity correction with the external apparatus was 64.2 ± 4.6% in the main curve and 60.7 ± 3.7% in the compensatory one. It was 72.8 ± 4.1% and 66.2 ± 5.3% immediately after treatment and 70.8 ± 4.6% and 64.3 ± 4.2% at long term, respectively. Pain relieved by 33.2 ± 4.2% (p < 0.05) immediately after treatment and by 55.6 ± 2.8% (p < 0.05) at long term. ODI reduced by 30.2 ± 1.7% (p < 0.05) immediately after treatment and by 37.2 ± 1.6% (p < 0.05) at long term. The apparatus for external transpedicular fixation provides gradual controlled correction for high-grade kyphoscoliosis in adolescents. Transition to internal fixation preserves the correction achieved, and correction is maintained at long term.

  10. Reconstruction with distraction osteogenesis for juxta-articular nonunions with bone loss.

    PubMed

    Kabata, Tamon; Tsuchiya, Hiroyuki; Sakurakichi, Keisuke; Yamashiro, Teruhisa; Watanabe, Koji; Tomita, Kasuro

    2005-06-01

    Nonunions of a juxta-articular lesion with bone loss, which represent a challenging therapeutic problem, were treated using external fixation and distraction osteogenesis. Seven juxta-articular nonunions (five septic and two aseptic) were treated. The location of the nonunion was the distal femur in four patients, the proximal tibia in one patient, and the distal tibia in two patients. All of them were located within 5 cm from the affected joints. Preoperative limb shortening was present in six cases, averaging 2.9 cm (range, 1-7 cm). The reconstructive procedure consisted of refreshment of the nonunion site, deformity correction, stabilization by external fixation, and lengthening to eliminate leg length discrepancy or to fill the defect. Shortening-distraction was applied to six patients and bone transport to one patient for reconstruction. Intramedullary nailing to reduce the duration of external fixation was simultaneously performed in two cases. All the patients had at least 1 year of follow-up evaluation. Osseous union without angular deformity or leg length discrepancy greater than 1 cm was achieved in all patients. The mean amount of lengthening was 5.8 cm (range, 2.2-10.0 cm). The mean external fixation period was 219 days (range, 98-317 days), and the mean external fixation index was 34.4 days/cm (range, 24.5-47.6 days/cm). All patients reported excellent pain reduction. There were no recurrences of infection in five patients with prior history of osteomyelitis. The functional results were categorized as excellent in two, good in three, and fair in two. Despite the length of postoperative external fixation, distraction osteogenesis can be a valuable alternative for the treatment of juxta-articular nonunions.

  11. Reconstruction of large diaphyseal bone defect by simplified bone transport over nail technique: A 7-case series.

    PubMed

    Ferchaud, F; Rony, L; Ducellier, F; Cronier, P; Steiger, V; Hubert, L

    2017-11-01

    Reconstruction of large diaphyseal bone defect is complex and the complications rate is high. This study aimed to assess a simplified technique of segmental bone transport by monorail external fixator over an intramedullary nail.A prospective study included 7 patients: 2 femoral and 5 tibial defects. Mean age was 31years (range: 16-61years). Mean follow-up was 62 months (range: 46-84months). Defects were post-traumatic, with a mean length of 7.2cm (range: 4 to 9.5cm). For 3 patients, reconstruction followed primary failure. In 4 cases, a covering flap was necessary. Transport used an external fixator guided by an intramedullary nail, at a rate of 1mm per day. One pin was implanted on either side of the distraction zone. The external fixator was removed 1 month after bone contact at the docking site. Mean bone transport time was 11 weeks (range: 7-15 weeks). Mean external fixation time was 5.1months (range: 3.5 to 8months). Full weight-bearing was allowed 5.7months (range: 3.5-13months) after initiation of transport. In one patient, a pin had to be repositioned. In 3 patients, the transported segment re-ascended after external fixatorablation, requiring repeat external fixation and resumption of transport. There was just 1 case of superficial pin infection. Reconstruction quality was considered "excellent" on the Paley-Marr criteria in 6 cases. The present technique provided excellent reconstruction quality in 6 of the 7 cases. External fixation time was shorter and resumption of weight-bearing earlier than with other reconstruction techniques, notably including bone autograft, vascularized bone graft or the induced membrane technique. Nailing facilitated control of limb axis and length. The complications rate was 50%, comparable to other techniques. This study raises the question of systematic internal fixation of the docking site, to avoid any mobilization of the transported segment. The bone quality, axial control and rapidity shown by the present technique make it well-adapted to reconstruction of diaphyseal bone defect. Four-case series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Tibial lengthening using a humeral intramedullary nail combined with a single-plane external fixator for leg discrepancy in sequelae of poliomyelitis.

    PubMed

    Chen, Daoyun; Chen, Jianmin; Liu, Fanggang; Jiang, Yao

    2011-03-01

    The sequelae of poliomyelitis are the common causes of leg discrepancy. Tibial lengthening is an effective way to solve this problem but it is associated with a high rate of complications. In this study, we combined the use of humeral nail and external fixator in tibial lengthening with the purpose of reducing lengthening complications. Compared with the cases lengthened by a single-plane external fixator alone, this combined strategy was found to be beneficial in maintaining the tibial alignment. Therefore, it can be recommended as a good technique for tibial lengthening in patients with sequelae of poliomyelitis.

  13. Open fractures caused by high velocity missiles: the outcome of treatment of 39 fractures followed for 1-3 years.

    PubMed

    Khan, M A; Hussain, R; Khan, S H; Umar, M

    1997-11-01

    Between 1993 and 1995, thirty-three patients having 39 fractures caused by missiles fired from a high velocity rifle were reviewed retrospectively between 1 and 3 years after injury and the outcome of treatment assessed. Majority (33 out of 39) were Grade III. Union was achieved in 35 out of 39 fractures, there was deep infection and delayed union in one case each. Non-union occurred in three fractures. The fractures were stabilized using different techniques, but highest complication rate was seen with the use of the static external fixator. This was related to the severe nature of the injury as well as the inherent limitations of the external fixator. Revision of the external fixator with internal fixation after healing of the soft tissues seems to be the direction of the future.

  14. External fixation of “intertrochanteric” fractures

    PubMed Central

    Gani, Naseem ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool

    2009-01-01

    In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with “intertrochanteric” fractures remain unsuita ble for open reduction and internal fixation. The aim of this study was to analyze the results of external fixation of “intertrochanteric” fractures in high-risk geriatric patients in a developing country. The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58–90 years) with “intertrochanteric” fractures, in whom external fixation was performed, are reported. Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients. This study demonstrated that external fixation of “intertrochantric” fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country. PMID:21808680

  15. External wire-frame fixation of digital skin grafts: a non-invasive alternative to the K-wire insertion method.

    PubMed

    Huang, Chenyu; Ogawa, Rei; Hyakusoku, Hiko

    2014-08-01

    The current skin graft fixation methods for digits, including the Kirschner wire insertion technique, can be limited by inadequate or excessive fixation and complications such as infection or secondary injuries. Therefore, the external wire-frame fixation method was invented and used for skin grafting of digits. This study aimed to investigate external wire-frame fixation of digital skin grafts as a non-invasive alternative to the K-wire insertion method. In 2005-2012, 15 patients with burn scar contractures on the hand digits received a skin graft that was then fixed with an external wire frame. The intra-operative time needed to make the wire frame, the postoperative time to frame and suture removal, the graft survival rate, the effect of contracture release and the complications were recorded. In all cases, the contracture release was 100%. The complete graft survival rate was 98.6%. Four patients had epithelial necrosis in <5% of the total area. There were no other complications such as pressure ulcer or hypoxia of fingers. External wire-frame fixation is simple, minimally invasive and a custom-made technique for skin grafting of the fingers. It was designed for its potential benefits and the decreased risk it poses to patients with scar contractures on their fingers. It can be implemented in three phases of grafting, does not affect the epiphyseal line or subsequent finger growth and is suitable for children with multi-digit involvement. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  16. Advantages of external hybrid fixators for treating Schatzker V-VI tibial plateau fractures: A retrospective study of 40 cases.

    PubMed

    Gross, J-B; Gavanier, B; Belleville, R; Coudane, H; Mainard, D

    2017-10-01

    Proximal tibia fractures make up 1% of all fractures in adults. The fractures classified as Schatzker V and VI fractures can compromise knee structure and function. They are challenging to treat and often have complications. While plate fixation is the gold standard, the resulting infection rate has led us to favor external hybrid fixation. The aims of this study were to assess the radiographic and functional outcomes along with the complication rate when using this method and to compare them to historical plate fixation data. This was a retrospective study of 40 patients. The complications, quality of reduction, IKS, Lysholm and Rasmussen functional scores at the latest follow-up and factors affecting the functional outcome were evaluated. These parameters were compared to published results from plate fixation studies. The deep infection rate was 2.5%. The union rate was 80%. Satisfactory reduction was obtained in 70% of cases; however, 52% of patients had malunion. The mean IKS score was 73.74, the mean Rasmussen score was 22.85 and the mean Lysholm score was 75.53. Age, reduction at latest follow-up, mechanical axis and anteroposterior laxity had a significant effect on the functional outcome. Despite the malunion rate being higher than other studies, the functional outcomes were nearly identical based on the variables measured. There are several advantages associated with using a hybrid external fixator: shorter operative time, less bleeding, shorter hospital stays and lower infection rate. Hybrid external fixation is a reliable fracture fixation method that leads to satisfactory functional outcomes, while reducing the infection rate and allowing arthroplasty to be performed in the future if needed. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Limb Lengthening and Then Insertion of an Intramedullary Nail: A Case-matched Comparison

    PubMed Central

    Kleinman, Dawn; Fragomen, Austin T.; Ilizarov, Svetlana

    2008-01-01

    Distraction osteogenesis is an effective method for lengthening, deformity correction, and treatment of nonunions and bone defects. The classic method uses an external fixator for both distraction and consolidation leading to lengthy times in frames and there is a risk of refracture after frame removal. We suggest a new technique: lengthening and then nailing (LATN) technique in which the frame is used for gradual distraction and then a reamed intramedullary nail inserted to support the bone during the consolidation phase, allowing early removal of the external fixator. We performed a retrospective case-matched comparison of patients lengthened with LATN (39 limbs in 27 patients) technique versus the classic (34 limbs in 27 patients). The LATN group wore the external fixator for less time than the classic group (12 versus 29 weeks). The LATN group had a lower external fixation index (0.5 versus 1.9) and a lower bone healing index (0.8 versus 1.9) than the classic group. LATN confers advantages over the classic method including shorter times needed in external fixation, quicker bone healing, and protection against refracture. There are also advantages over the lengthening over a nail and internal lengthening nail techniques. Level of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18800209

  18. PreFix™ external fixator used to treat a floating shoulder injury caused by gunshot wound.

    PubMed

    Vogels, J; Pommier, N; Cursolle, J-C; Belin, C; Tournier, C; Durandeau, A

    2014-10-01

    Open fractures of the shoulder are extremely rare, and their treatment is a major challenge for surgeons. Only cases encountered in military settings have been reported thus far. Such fractures are often the result of ballistic trauma, which causes extensive damage to both bony and soft tissues. Since these injuries are associated with a high risk of infection and the presence of comminuted fractures, external fixation is necessary for repair. Use of external fixators and revascularization techniques has reduced the number of cases requiring shoulder amputation or disarticulation. Injury to the proximal extremity of the humerus, acromion, and clavicle further complicates the treatment. No published studies have described the assembly of external fixators for fractures in the scapular region with significant bone loss. In addition, no cases have been described in civilian settings. However, with an increase in urban violence and the traffic of illegal arms, civilian surgeons are now encountering an increasing number of patients with these injuries. In this report, we not only present a rare case of floating shoulder injury in a civilian setting but also provide an overview of the existing treatment strategies for this type of trauma, with special focus on the use of external fixators in elective shoulder arthrodesis and on military cases. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. [Tensile strength of bone fixation of hydroxyapatite coated Schanz screws of the Heidelberg External Fixation System (HEFS)--comparative torque measurements in clinical use and in cadaver tibia].

    PubMed

    Placzek, R; Deuretzbacher, G; Meiss, A L

    2002-12-01

    It is claimed in the literature that hydroxyapatite(HA)-coated screws of external fixators have superior fixation strength in bone, which is postulated to lead to a substantial decrease in loosening and infection rates. We report on a study of the maximum torque values developed while inserting and removing 30 HA-coated Schanz screws of 8 Heidelberg external fixation systems applied to the tibia to correct leg length differences and axial deformities. The infection rate was determined in accordance with defined criteria, and was found to be about 20% for the HA-coated screws. Screws without infection showed an extraction torque above insertion torque, screws with infection an extraction torque below. A significant correlation (p = 0.05) was seen between infection and decrease in fixation strength (quotient: loosening torque/tightening torque). To exclude the impact of such biological processes as osteointegration and bone remodelling, the clinical results were compared with the torques measured for coated and uncoated Schanz screws in a human cadaveric tibia. A significantly higher fixation strength in bone was found for HA-coated screws in comparison with uncoated screws (p = 0.002). These data warrant a clinical study directly comparing HA-coated and uncoated Schanz screws.

  20. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  1. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  2. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  3. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  4. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  5. Internal versus external fixation of the anterior component in unstable fractures of the pelvic ring: pooled results from a systematic review.

    PubMed

    Wardle, B; Eslick, G D; Sunner, P

    2016-10-01

    Improving reduction of the pelvic ring improves long-term functional outcomes for patients. It has been demonstrated that posterior internal fixation is necessary to adequately control fractures to the posterior ring and there is evidence that supplementing this with fixation of the anterior ring improves stability. It is accepted that internal fixation provides greater stability than external fixation of the anterior ring but long-term differences in radiographic and functional outcomes have not yet been quantified. A search of electronic databases, reference lists and review articles from 1989 to 2015 yielded 18 studies (n = 884) that met our inclusion criteria. We included studies that discussed pelvic ring injuries in adults, reported functional or radiological outcomes or complications by anterior ring intervention and exceeded 14 patients. We excluded biomechanical and cadaver studies. Internal fixation of the anterior pelvic ring had better functional and radiographic outcomes. Residual displacement of >10 mm was less common with internal fixation (ER 0.12, 95 % CI 0.06-0.24) than external fixation (ER 0.31, 95 % CI 0.11-0.62). Unsatisfactory outcomes also occurred at a lower rate (ER 0.09, 95 % CI 0.03-0.22) compared to external fixation (ER 0.32, 95 % CI 0.18-0.50). Losses of reduction (ER 0.02, 95 % CI 0.01-0.04 versus ER 0.07, 95 % CI 0.02-0.21), malunions (ER 0.03, 95 % CI 0.01-0.08 versus ER 0.07, 95 % CI 0.02-0.21) and delayed/non-unions (ER 0.02, 95 % CI 0.01-0.05 versus ER 0.04, 95 % CI 0.02-0.07). Internal fixation of the anterior pelvic ring as supplementary fixation for unstable injuries to the pelvic ring appears to result in better radiographic and functional outcomes as well as fewer complications. However, data that separated outcomes and complications in relation to interventions of the anterior pelvic ring were limited. More studies looking specifically at outcomes in relation to the type of anterior ring intervention are needed.

  6. Operative Fixation Options for Elective and Diabetic Ankle Arthrodesis.

    PubMed

    Ramanujam, Crystal L; Stapleton, John J; Zgonis, Thomas

    2017-07-01

    Ankle arthrodesis remains one of the most definitive treatment options for end-stage arthritis, paralysis, posttraumatic and postinfectious conditions, failed total ankle arthroplasty, and severe deformities. The general aims of ankle arthrodesis are to decrease pain and instability, correct the accompanying deformity, and create a stable plantigrade foot. Several surgical approaches have been reported for ankle arthrodesis with internal fixation options. External fixation has also evolved for ankle arthrodesis in certain clinical scenarios. This article provides a comprehensive analysis of midterm to long-term outcomes for ankle arthrodesis using internal and/or external fixation each for elective and diabetic conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Improved Healing of Large, Osseous, Segmental Defects by Reverse Dynamization: Evaluation in a Sheep Model

    DTIC Science & Technology

    2014-10-01

    initiated. One such fixator has been tested on a cadaveric sheep tibia. In the unlocked, loose position, the axial stiffness of the tibia and fixator...suggested by our previous studies using rats. This aspect of the project is the present focus of attention, and additional cadaver legs will be tested...characterize external fixators). A 3 mm tibial defect was created in the leg of a cadaveric sheep, and stabilized with an experimental external

  8. Treatment of displaced intra-articular calcaneal fractures with triangular tube-to-bar external fixation: long-term clinical follow-up and radiographic analysis.

    PubMed

    Roukis, Thomas S; Wünschel, Markus; Lutz, Hans-Peter; Kirschner, Peter; Zgonis, Thomas

    2008-04-01

    Sixty-six feet (62 patients) with displaced intra-articular calcaneal fractures underwent manual reduction and distraction with the use of a triangular tube-to-bar external fixation device and were retrospectively reviewed at a minimum of 1-year post-operative. Final radiographic follow-up revealed complete consolidation in all fractures, maintenance of reduction, and limited degenerative osteoarthrosis about the subtalar joint. Our results indicate that with proper application and attention to detail, restoration of calcaneal morphology using triangular tube-to-bar external fixation should be considered a viable alternative in the treatment of displaced intra-articular fractures of the calcaneus.

  9. Temporary Stabilization with External Fixator in 'Tripolar' Configuration in Two Steps Treatment of Tibial Pilon Fractures.

    PubMed

    Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè

    2016-01-01

    The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation. Temporary stabilization with external fixator in 'tripolar' configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases.

  10. Limb lengthening over plate

    PubMed Central

    Kulkarni, Ruta; Singh, Nishant; Kulkarni, Govind S; Kulkarni, Milind; Kulkarni, Sunil; Kulkarni, Vidisha

    2012-01-01

    Background: The limb lengthening over plate eliminates the associated risk of infection with limb lengthening over intramedullary nail. We present our experience of limb lengthening in 15 patients with a plate fixed on the proximal segment, followed by corticotomy and application of external fixator. Materials and Methods: 15 patients (7 females, 8 males) were included in this consecutive series. The average age was 18.1 years (range 8–35 years). Fifteen tibiae and one femur were lengthened in 15 patients. Lengthening was achieved at 1 mm/day followed by distal segment fixation with three or four screws on reaching the target length. Results: The preoperative target length was successfully achieved in all patients at a mean of 4.1 cm (range 1.8–6.5 cm). The mean duration of external fixation was 75.3 days (range 33–116 days) with the mean external fixation index at 19.2 days/cm (range 10.0–38.3 days/cm). One patient suffered deep infection up to the plate, three patients had mild procurvatum deformities, and one patient developed mild tendo achilles contracture. Conclusion: Lengthening over a plate allows early removal of external fixator and eliminates the risk of creating deep intramedullary infection as with lengthening over nail. Lengthening over plate is also applicable to children with open physis. PMID:22719123

  11. Better Axial Stiffness of a Bicortical Screw Construct Compared to a Cable Construct for Comminuted Vancouver B1 Proximal Femoral Fractures.

    PubMed

    Griffiths, Jamie T; Taheri, Arash; Day, Robert E; Yates, Piers J

    2015-12-01

    The aim of this study was to biomechanically evaluate the Locking attachment plate (LAP) construct in comparison to a Cable plate construct, for the fixation of periprosthetic femoral fractures after cemented total hip arthroplasty. Each construct incorporated a locking compression plate with bi-cortical locking screws for distal fixation. In the Cable construct, 2 cables and 2 uni-cortical locking screws were used for proximal fixation. In the LAP construct, the cables were replaced by a LAP with 4 bi-cortical locking screws. The LAP construct was significantly stiffer than the cable construct under axial load with a bone gap (P=0.01). The LAP construct offers better axial stiffness compared to the cable construct in the fixation of comminuted Vancouver B1 proximal femoral fractures. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  12. The computer-aided parallel external fixator for complex lower limb deformity correction.

    PubMed

    Wei, Mengting; Chen, Jianwen; Guo, Yue; Sun, Hao

    2017-12-01

    Since parameters of the parallel external fixator are difficult to measure and calculate in real applications, this study developed computer software that can help the doctor measure parameters using digital technology and generate an electronic prescription for deformity correction. According to Paley's deformity measurement method, we provided digital measurement techniques. In addition, we proposed an deformity correction algorithm to calculate the elongations of the six struts and developed a electronic prescription software. At the same time, a three-dimensional simulation of the parallel external fixator and deformed fragment was made using virtual reality modeling language technology. From 2013 to 2015, fifteen patients with complex lower limb deformity were treated with parallel external fixators and the self-developed computer software. All of the cases had unilateral limb deformity. The deformities were caused by old osteomyelitis in nine cases and traumatic sequelae in six cases. A doctor measured the related angulation, displacement and rotation on postoperative radiographs using the digital measurement techniques. Measurement data were input into the electronic prescription software to calculate the daily adjustment elongations of the struts. Daily strut adjustments were conducted according to the data calculated. The frame was removed when expected results were achieved. Patients lived independently during the adjustment. The mean follow-up was 15 months (range 10-22 months). The duration of frame fixation from the time of application to the time of removal averaged 8.4 months (range 2.5-13.1 months). All patients were satisfied with the corrected limb alignment. No cases of wound infections or complications occurred. Using the computer-aided parallel external fixator for the correction of lower limb deformities can achieve satisfactory outcomes. The correction process can be simplified and is precise and digitized, which will greatly improve the treatment in a clinical application.

  13. An Efficient and Reproducible Protocol for Distraction Osteogenesis in a Rat Model Leading to a Functional Regenerated Femur.

    PubMed

    Pithioux, Martine; Roseren, Flavy; Jalain, Christian; Launay, Franck; Charpiot, Philippe; Chabrand, Patrick; Roffino, Sandrine; Lamy, Edouard

    2017-10-23

    This protocol describes the use of a newly developed external fixator for distraction osteogenesis in a rat femoral model. Distraction osteogenesis (DO) is a surgical technique leading to bone regeneration after an osteotomy. The osteotomized extremities are moved away from each other by gradual distraction to reach the desired elongation. This procedure is widely used in humans for lower and upper limb lengthening, treatment after a bone nonunion, or the regeneration of a bone defect following surgery for bone tumor excision, as well as in maxillofacial reconstruction. Only a few studies clearly demonstrate the efficiency of their protocol in obtaining a functional regenerated bone, i.e., bone that will support physiological weight-bearing without fracture after removal of the external fixator. Moreover, protocols for DO vary and reproducibility is limited by lack of information, making comparison between studies difficult. The aim of this study was to develop a reproducible protocol comprising an appropriate external fixator design for rat limb lengthening, with a detailed surgical technique that permits physiological weight-bearing by the animal after removal of the external fixator.

  14. Adjustable stiffness, external fixator for the rat femur osteotomy and segmental bone defect models.

    PubMed

    Glatt, Vaida; Matthys, Romano

    2014-10-09

    The mechanical environment around the healing of broken bone is very important as it determines the way the fracture will heal. Over the past decade there has been great clinical interest in improving bone healing by altering the mechanical environment through the fixation stability around the lesion. One constraint of preclinical animal research in this area is the lack of experimental control over the local mechanical environment within a large segmental defect as well as osteotomies as they heal. In this paper we report on the design and use of an external fixator to study the healing of large segmental bone defects or osteotomies. This device not only allows for controlled axial stiffness on the bone lesion as it heals, but it also enables the change of stiffness during the healing process in vivo. The conducted experiments have shown that the fixators were able to maintain a 5 mm femoral defect gap in rats in vivo during unrestricted cage activity for at least 8 weeks. Likewise, we observed no distortion or infections, including pin infections during the entire healing period. These results demonstrate that our newly developed external fixator was able to achieve reproducible and standardized stabilization, and the alteration of the mechanical environment of in vivo rat large bone defects and various size osteotomies. This confirms that the external fixation device is well suited for preclinical research investigations using a rat model in the field of bone regeneration and repair.

  15. Early Conversion of External Fixation to Interlocked Nailing in Open Fractures of Both Bone Leg Assisted with Vacuum Closure (VAC) - Final Outcome

    PubMed Central

    Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash

    2016-01-01

    Introduction Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. Aim To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. Materials and Methods In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Results Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian’s criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Conclusion Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA/B fractures without increasing the risk of infection. It gives better stability to fracture site and lessen the risk of implant failure. PMID:27042541

  16. Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws.

    PubMed

    Lapsiwala, Samir B; Anderson, Paul A; Oza, Ashish; Resnick, Daniel K

    2006-03-01

    We performed a biomechanical comparison of several C1 to C2 fixation techniques including crossed laminar (intralaminar) screw fixation, anterior C1 to C2 transarticular screw fixation, C1 to 2 pedicle screw fixation, and posterior C1 to C2 transarticular screw fixation. Eight cadaveric cervical spines were tested intact and after dens fracture. Four different C1 to C2 screw fixation techniques were tested. Posterior transarticular and pedicle screw constructs were tested twice, once with supplemental sublaminar cables and once without cables. The specimens were tested in three modes of loading: flexion-extension, lateral bending, and axial rotation. All tests were performed in load and torque control. Pure bending moments of 2 nm were applied in flexion-extension and lateral bending, whereas a 1 nm moment was applied in axial rotation. Linear displacements were recorded from extensometers rigidly affixed to the C1 and C2 vertebrae. Linear displacements were reduced to angular displacements using trigonometry. Adding cable fixation results in a stiffer construct for posterior transarticular screws. The addition of cables did not affect the stiffness of C1 to C2 pedicle screw constructs. There were no significant differences in stiffness between anterior and posterior transarticular screw techniques, unless cable fixation was added to the posterior construct. All three posterior screw constructs with supplemental cable fixation provide equal stiffness with regard to flexion-extension and axial rotation. C1 lateral mass-C2 intralaminar screw fixation restored resistance to lateral bending but not to the same degree as the other screw fixation techniques. All four screw fixation techniques limit motion at the C1 to 2 articulation. The addition of cable fixation improves resistance to flexion and extension for posterior transarticular screw fixation.

  17. Perioperative management of external fixation in staged protocols: an international survey.

    PubMed

    Hodel, Sandro; Link, Björn-Christian; Babst, Reto; Mallee, W H; Posso, Philippe; Beeres, Frank J P

    2018-05-01

    Despite the frequent use of external fixation, various regimes of antibiotic prophylaxis, surgical technique and postoperative pin care exist and underline the lack of current evidence. The aim of the study was to assess the variability or consensus in perioperative protocols to prevent implant-associated infections for temporary external fixation in closed fractures of the extremities. A 26-question survey was sent to 170 members of the Traumaplatform. The survey included questions concerning demographics, level of training, type of training and perioperative protocols as: antibiotic prophylaxis, intraoperative management, disinfection and postoperative pin site care. All responses were statistically analysed, and intraoperative measures rated on a 5-point Likert scale. The responses of fifty orthopaedic trauma and general surgeons (response rate, 29.4%) were analysed. The level of experience was more than 5 years in 92% (n = 46) with up to 50 closed fractures of the extremities annually treated with external fixation in 80% (n = 40). Highest consensus could be identified in the following perioperative measures: preoperative antibiotic prophylaxis with a second-generation cephalosporin (86%, n = 43), changing gloves if manipulation of the external fixator is necessary during surgery (86%, n = 43; 4.12 points on the Likert scale), avoid overlapping of the pin sites with the definitive implant site (94%, n = 47; 4.12 points on the Likert scale) and soft tissue protection with a drill sleeve (83.6%, n = 41). Our survey could identify some general principles, which were rated as important by a majority of the respondents. Futures studies' focus should elucidate the role of perioperative antibiotics and different disinfection protocols on implant-associated infections after temporary external fixation in staged protocols. This study provides Level IV evidence according to Oxford centre for evidence-based medicine.

  18. Less-invasive stabilization of rib fractures by intramedullary fixation: a biomechanical evaluation.

    PubMed

    Bottlang, Michael; Helzel, Inga; Long, William; Fitzpatrick, Daniel; Madey, Steven

    2010-05-01

    This study evaluated intramedullary fixation of rib fractures with Kirschner wires and novel ribs splints. We hypothesized that rib splints can provide equivalent fixation strength while avoiding complications associated with Kirschner wires, namely wire migration and cutout. The durability, strength, and failure modes of rib fracture fixation with Kirschner wires and rib splints were evaluated in 22 paired human ribs. First, intact ribs were loaded to failure to determine their strength. After fracture fixation with Kirschner wires and rib splints, fixation constructs were dynamically loaded to 360,000 cycles at five times the respiratory load to determine their durability. Finally, constructs were loaded to failure to determine residual strength and failure modes. All constructs sustained dynamic loading without failure. Dynamic loading caused three times more subsidence in Kirschner wire constructs (1.2 mm +/- 1.4 mm) than in rib splint constructs (0.4 mm +/- 0.2 mm, p = 0.09). After dynamic loading, rib splint constructs remained 48% stronger than Kirschner wire constructs (p = 0.001). Five of 11 Kirschner wire constructs failed catastrophically by cutting through the medial cortex, leading to complete loss of stability and wire migration through the lateral cortex. The remaining six constructs failed by wire bending. Rib splint constructs failed by development of fracture lines along the superior and interior cortices. No splint construct failed catastrophically, and all splint constructs retained functional reduction and fixation. Because of their superior strength and absence of catastrophic failure mode, rib splints can serve as an attractive alternative to Kirschner wires for intramedullary stabilization of rib fractures, especially in the case of posterior rib fractures where access for plating is limited.

  19. An original knee arthrodesis technique combining external fixator with Steinman pins direct fixation.

    PubMed

    Riouallon, G; Molina, V; Mansour, C; Court, C; Nordin, J-Y

    2009-06-01

    Knee arthrodesis may be the last possible option for infected total knee arthroplasty (TKA) patients and in revision cases involving severe bone loss and/or extensor mechanism damages. Success in these situations depends on achieving good fixation assembly stability. We report bone fusion results using a fixation technique combining cross-pinning by two Steinman pins with a single-frame external fixator. Remission of infection at long-term follow-up was an additional criteria assessed for those cases initially treated for sepsis. This fixation modality improves fusion rates. In six of this series of eight patients (mean age: 59 years), surgery was performed in a context of infection: five cases of infected TKA, and one case of septic arthritis. In the other two cases, arthrodesis was respectively indicated for a severe post-traumatic stiffness compounded by extensor system rupture and for a fracture combined to a complete mechanical implant loosening. In three of the six infection cases, arthrodesis was performed as a single-stage procedure. All patients were operated on using the same technique: primary arthrodesis site stabilization by frontal cross-pinning with two Steinman pins, followed by installation of a sagittal external fixator frame. Results were assessed at a mean 8 year follow-up. All the arthrodeses showed fusion at a mean 3.5 months (range: 2.5 to 6 months) postoperative delay without reintervention. Weight-bearing was resumed at 2 to 3 months. The external fixator was removed at a mean 5.2 months. No recurrence of infection was observed over a mean follow-up of 8.2 years (range: 1 to 15 years). Three complications occurred: one hematoma, managed surgically; one supracondylar fracture treated orthopedically; and one osteitis, managed by surgical curettage. This knee arthrodesis technique proved effective, with no failures in this short series, especially in cases of primary infection. It is a reproducible means of osteosynthesis, with little subsequent morbidity. Fixation in two orthogonal planes seemed to provide the stability required to achieve bone fusion. This assembly avoids internal fixation, which is never risk-free in a context of primary sepsis. Level IV. Retrospective study. 2009 Elsevier Masson SAS. All rights reserved.

  20. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation

    PubMed Central

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-01-01

    Abstract The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation. Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups. The mean follow-up time was 18.6 months (range: 5–24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5–9 months) and 6.0 months (range: 5–8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°–150°) and 135° (range: 100°–160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05). External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation. PMID:29019890

  1. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation.

    PubMed

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-10-01

    The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5-9 months) and 6.0 months (range: 5-8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°-150°) and 135° (range: 100°-160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.

  2. Biomechanical Concepts for Fracture Fixation

    PubMed Central

    Bottlang, Michael; Schemitsch, Christine E.; Nauth, Aaron; Routt, Milton; Egol, Kenneth; Cook, Gillian E.; Schemitsch, Emil H.

    2015-01-01

    Application of the correct fixation construct is critical for fracture healing and long-term stability; however, it is a complex issue with numerous significant factors. This review describes a number of common fracture types, and evaluates their currently available fracture fixation constructs. In the setting of complex elbow instability, stable fixation or radial head replacement with an appropriately sized implant in conjunction with ligamentous repair is required to restore stability. For unstable sacral fractures, “standard” iliosacral screw fixation is not sufficient for fractures with vertical or multiplanar instabilities. Periprosthetic femur fractures, in particular Vancouver B1 fractures, have increased stability when using 90/90 fixation versus a single locking plate. Far Cortical Locking combines the concept of dynamization with locked plating in order to achieve superior healing of a distal femur fracture. Finally, there is no ideal construct for syndesmotic fracture stabilization; however, these fractures should be fixed using a device that allows for sufficient motion in the syndesmosis. In general, orthopaedic surgeons should select a fracture fixation construct that restores stability and promotes healing at the fracture site, while reducing the potential for fixation failure. PMID:26584263

  3. Functional pedal construct achieved by combined operative treatment in peritalar complex Charcot arthropathy: A prospective study of 38 feet.

    PubMed

    El-Mowafi, Hani; El-Hawary, Ahmed; Kandil, Yasser

    2017-03-06

    Charcot arthropathy of the peritalar complex carries a high risk of amputation if not properly managed. Our aim is to assess the functional outcome of severe Charcot arthropathy of the peritalar complex following enblock resection of the ulcer, massive debridement and stabilizing all the elements of the peritalar complex. We prospectively studied 38 feet in 35 patients with peritalar complex Charcot arthropathy. All Feet underwent intense debridement and fusion using a combination of (Ilizarov) external fixation, and (plate and locked nail) internal fixation. Thirty two feet were graded as Eichenholtz 2, and six feet were graded as Eichenholtz 3. The mean follow up was 35.9months. The mean AOFAS score was significantly elevated from 25.4±9.1 preoperatively to 67.6±5.7 at the most recent follow-up (p<0.001). Complete bony fusion was achieved in 28 feet. Unsound bony fusion occurred in 8 feet. Two feet required below knee amputation. Peritalar complex Charcot arthropathy is not uncommon variety. Such cases carry high risk of complications and amputation is not excluded. The proper timing of surgery is crucial. Massive debridement and rigid fixation with strict follow up is mandatory to achieve the ultimate goal of obtaining a plantigrade, stable, mechanically sound, painless and infection free pedal construct. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  4. In vitro evaluation of the torsional strength reduction of neonate calf metatarsal bones with Bicortical defects resulting from the removal of external fixation implants.

    PubMed

    Brianza, Stefano; Vogel, Susan; Rothstock, Stephan; Desrochers, Andrè; Boure, Ludovic

    2013-01-01

    To compare the torsional strength of calf metatarsal bones with defects produced by removal of 2 different implants. In vitro mechanical comparison of paired bones with bicortical defects resulting from the implantation of 2 different external fixation systems: the transfixation pin (TP) and the pin sleeve system (PS). Neonatal calf metatarsal bones (n = 6 pairs). From each pair, 1 bone was surgically instrumented with 2 PS implants and the contralateral bone with 2 TP implants. Implants were removed immediately leaving bicortical defects at identical locations between paired metatarsi. Each bone was tested in torque until failure. The mechanical variables statistically compared were the torsional stiffness, the torque and angle at failure, and work to failure. For TP and PS constructs, respectively, there were no significant differences between construct types for any of the variables tested. Mean ± SD torsional stiffness: 5.50 ± 2.68 and 5.35 ± 1.79 (Nm/°), P = .75; torque: 57.42 ± 14.84 and 53.43 ± 10.16 (Nm); P = .34; angle at failure: 14.76 ± 4.33 and 15.45 ± 4.84 (°), P = .69; and work to failure 7.45 ± 3.19 and 8.89 ± 3.79 (J), P = .17). Bicortical defects resulting from the removal of PS and TP implants equally affect the investigated mechanical properties of neonate calf metatarsal bones. © Copyright 2012 by The American College of Veterinary Surgeons.

  5. [Effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation].

    PubMed

    Ge, Qihang; Wan, Chunyou; Liu, Yabei; Ji, Xu; Ma, Jihai; Cao, Haikun; Yong, Wei; Liu, Zhao; Zhang, Ningning

    2017-08-01

    To investigate the effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation. The data of 45 cases with tibial and fibular open fractures treated by Taylor space stent fixation who meet the selection criteria between January 2015 and June 2016 were retrospectively analysed. The patients were divided into trial group (23 cases) and control group (22 cases) according to whether the axial stress stimulation was performed after operation. There was no significant difference in gender, age, affected side, cause of injury, type of fracture, and interval time from injury to operation between 2 groups ( P >0.05). The axial stress stimulation was performed in trial group after operation. The axial load sharing ratio was tested, and when the value was less than 10%, the external fixator was removed. The fracture healing time, full weight-bearing time, and external fixator removal time were recorded and compared. After 6 months of external fixator removal, the function of the limb was assessed by Johner-Wruhs criteria for evaluation of final effectiveness of treatment of tibial shaft fractures. There were 2 and 3 cases of needle foreign body reaction in trial group and control group, respectively, and healed after symptomatic anti allergic treatment. All the patients were followed up 8-12 months with an average of 10 months. All the fractures reached clinical healing, no complication such as delayed union, nonunion, or osteomyelitis occurred. The fracture healing time, full weight-bearing time, and external fixator removal time in trial group were significantly shorter than those in control group ( P <0.05). After 6 months of external fixator removal, the function of the limb was excellent in 13 cases, good in 6 cases, fair in 3 cases, and poor in 1 case in trial group, with an excellent and good rate of 82.6%; and was excellent in 5 cases, good in 10 cases, fair in 4 cases, and poor in 3 cases in control group, with an excellent and good rate of 68.2%, showing significant difference between 2 groups ( Z =-2.146, P =0.032). The axial stress stimulation of Taylor space stent fixation can promote the healing of tibial and fibular open fractures and promote local bone formation at fracture site.

  6. A comparison of bicortical and intramedullary screw fixations of Jones' fractures.

    PubMed

    Husain, Zeeshan S; DeFronzo, Donna J

    2002-01-01

    Two different fixations for treatment of Jones' fracture were tested in bone models and cadaveric specimens to determine the differences in the stability of the constructs. A bicortical 3.5-mm cannulated cortical screw and an intramedullary 4.0-mm partially threaded cancellous screw were tested using physiologic loads with an Instron 8500 servohydraulic tensiometer (Instron Corporation, Canton, MA). In bone models, the bicortical construct (n = 5, 87+/-23 N) showed superior fixation strength (p = .0009) when compared to the intramedullary screw fixation (n = 5, 25+/-13 N). Cadaveric testing showed similar statistical significance (p = .0124) with the bicortical construct (n = 5, 152+/-71 N) having greater load resistance than the intramedullary screw fixation (n = 4, 29+/-20 N). In bone models, the bicortical constructs (23+/-9 N/mm) showed over twice the elastic modulus than the intramedullary screw fixations (9+/-4 N/mm) with statistical significance (p = .0115). The elastic modulus in the cadaveric group showed a similar pattern between the bicortical (19+/-17 N/mm) and intramedullary (9+/-6 N/mm) screw constructs. Analysis of the bicortical screw failure patterns revealed that screw orientation had a critical impact on fixation stability. The more distal the exit site of the bicortical screw was from the fracture site, the greater the load needed to displace the fixation.

  7. No Higher Risk of CRPS After External Fixation of Distal Radial Fractures - Subgroup Analysis Under Randomised Vitamin C Prophylaxis.

    PubMed

    Zollinger, Paul E; Kreis, Robert W; van der Meulen, Hub G; van der Elst, Maarten; Breederveld, Roelf S; Tuinebreijer, Wim E

    2010-02-17

    Operative and conservative treatment of wrist fractures might lead to complex regional pain syndrome (CRPS) type I.In our multicenter dose response study in which patients with distal radial fractures were randomly allocated to placebo or vitamin C in a daily dose of 200mg, 500mg or 1500mg during 50 days, an operated subgroup was analyzed.48 (of 427) fractures) were operated (11.2%). Twenty-nine patients (60%) were treated with external fixation, 14 patients (29%) with K-wiring according to Kapandji and five patients (10%) with internal plate fixation. The 379 remaining patients were treated with a plaster.In the operated group of patients who received vitamin C no CRPS (0/37) was seen in comparison with one case of CRPS (Kapandji technique) in the operated group who received placebo (1/11 = 9%, p=.23). There was no CRPS after external fixation.In the conservatively treated group 17 cases of CRPS (17/379 = 4.5%) occurred in comparison with one in case of CRPS in the operated group (1/48 = 2.1%, p=.71).External fixation doesn't necessarily lead to a higher incidence of CRPS in distal radial fractures. Vitamin C may also play a role in this. This subgroup analysis in operated distal radial fractures showed no CRPS occurrence with vitamin C prophylaxis.

  8. Temporary Stabilization with External Fixator in ‘Tripolar’ Configuration in Two Steps Treatment of Tibial Pilon Fractures

    PubMed Central

    Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè

    2016-01-01

    Background: The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. Methods: We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. Results: We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation Conclusion: Temporary stabilization with external fixator in ‘tripolar’ configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases. PMID:27123151

  9. Monoaxial external fixation of the calcaneus: An anatomical study assessing the safety of monoaxial pin insertion.

    PubMed

    Thomson, Callum M; Esparon, Tom; Rea, Paul M; Jamal, Bilal

    2016-10-01

    The use of external fixation for intra-articular calcaneal fractures is increasing in popularity. Studies have shown fine wire and monoaxial external fixation to be a viable surgical alternative to more invasive methods of open reduction and internal fixation of the calcaneus. However, there is an absence of literature that quantifies the risk of pin insertion for monoaxial fixation. This study aimed to determine the safety of inserting monoaxial pins within the calcaneus to house the Orthofix Calcaneal Mini-Fixator. Five formalin embalmed cadaveric ankle and lower leg specimens were inserted with six monoaxial pins. Careful dissection then revealed the presence of the tendons of peroneus longus and brevis, the sural nerve and the small saphenous vein in relation to these pins. Measurements from each pin to each of these structures were made as the structures transected lines drawn from each pin to two palpable bony landmarks: the inferior tip of the lateral malleolus and the posterosuperior calcaneus. In doing this, the risk posed by each pin could be evaluated. We found that two particular pins, those used to hold the articular surface of the subtalar joint in a reduced position, posed a larger risk of injury to surrounding structures than the remaining pins. These findings therefore suggest that monoaxial fixation of the calcaneus using a six pin approach is a relatively safe method of rectifying calcaneal fractures and thus may serve as a welcome alternative to other methods of calcaneal fixation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Comparison of Risk of Carpal Tunnel Syndrome in Patients with Distal Radius Fractures After 7 Treatments

    PubMed Central

    Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei

    2015-01-01

    Background To compare risk of carpal tunnel syndrome (CTS) in distal radius fracture (DRF) patients after 7 treatments using bridging external fixation (BrEF), non-bridging external fixation (non-BrEF), plaster fixation, K-wire fixation, dorsal plating fixation, volar plating fixation, and dorsal and volar plating by performing a network meta-analysis. Material/Methods An exhaustive search of electronic databases identified randomized controlled trails (RCTs) closely related to our study topic. The published articles were screened, based on predefined inclusion and exclusion criteria, to select high-quality studies for the present network meta-analysis. Data extracted from the selected studies were analyzed using STATA version 12.0 software. Results The literature search and selection process identified 12 eligible RCTs that contained a total of 1370 DRF patients (394 patients with BrEF, 377 patients with non-BrEF, 89 patients with K-wire fixation, 192 patients with plaster fixation, 42 patients with dorsal plating fixation, 152 patients with volar plating fixation, and 124 patients with dorsal and volar plating fixation). Our network meta-analysis results demonstrated no significant differences in CTS risk among the 7 treatments (P>0.05). The value of surface under the cumulative ranking curve (SUCRA), however, suggested that dorsal plating fixation is the optimal treatment, with the lowest risk of CTS in DRF patients (dorsal plating fixation: 89.2%; dorsal and volar plating: 57.8%; plaster fixation: 50.9%; non-BrEF: 50.6%; volar plating fixation: 39.6%; BrEF: 38.4%; K-wire fixation: 23.6%). Conclusions Our network meta-analysis provides evidence that dorsal plating fixation significantly decreases the risk of CTS and could be the method of choice in DRF patients. PMID:26391617

  11. Syndesmotic fixation in supination-external rotation ankle fractures: a prospective randomized study.

    PubMed

    Pakarinen, Harri J; Flinkkilä, Tapio E; Ohtonen, Pasi P; Hyvönen, Pekka H; Lakovaara, Martti T; Leppilahti, Juhana I; Ristiniemi, Jukka Y

    2011-12-01

    This study was designed to assess whether transfixion of an unstable syndesmosis is necessary in supination-external rotation (Lauge-Hansen SE/Weber B)-type ankle fractures. A prospective study of 140 patients with unilateral Lauge-Hansen supination-external rotation type 4 ankle fractures was done. After bony fixation, the 7.5-Nm standardized external rotation (ER) stress test for both ankles was performed under fluoroscopy. A positive stress examination was defined as a difference of more than 2 mm side-to-side in the tibiotalar or tibiofibular clear spaces on mortise radiographs. If the stress test was positive, the patient was randomized to either syndesmotic transfixion with 3.5-mm tricortical screws or no syndesmotic fixation. Clinical outcome was assessed using the Olerud-Molander scoring system, RAND 36-Item Health Survey, and Visual Analogue Scale (VAS) to measure pain and function after a minimum 1-year of followup. Twenty four (17%) of 140 patients had positive standardized 7.5-Nm ER stress tests after malleolar fixation. The stress view was positive three times on tibiotalar clear space, seven on tibiofibular clear space, and 14 times on both tibiotalar and tibiofibular clear spaces. There was no significant difference between the two randomization groups with regards to Olerud-Molander functional score, VAS scale measuring pain and function, or RAND 36-Item Health Survey pain or physical function at 1 year. Relevant syndesmotic injuries are rare in supination-external rotation ankle fractures, and syndesmotic transfixion with a screw did not influence the functional outcome or pain after the 1-year followup compared with no fixation.

  12. Arthrodesis for failed knee arthroplasty. A report of 20 cases.

    PubMed

    Knutson, K; Lindstrand, A; Lidgren, L

    1985-01-01

    Twenty consecutive patients treated by arthrodesis for failed knee arthroplasty are reviewed. Eight hinged, five stabilised and seven compartmental prostheses were removed, for infection (15 cases), loosening (4) and instability (1). One patient refused a second-stage operation but the remainder gained sound fusion. Infected knees had a two-stage procedure with temporary insertion of gentamicin-loaded beads after removal of the prosthesis; all infections healed. Six arthrodeses using a Hoffmann-Vidal external fixator resulted in two temporary failures. One Ace-Fischer external fixation was successful. Of 10 primary attempts at arthrodesis with an intramedullary Küntscher nail, nine were successful; the tenth fused after two more attempts by the same method. The two failures of external fixation and two failures after Charnley single-frame compression done elsewhere were successfully fused with intramedullary nails. Delayed union in three cases fused after prolonged fixation and repeated bone grafts. The indications for and methods of arthrodesis after failed knee arthroplasty are discussed.

  13. Pearls and pitfalls of deformity correction and limb lengthening via monolateral external fixation.

    PubMed Central

    Noonan, K. J.; Price, C. T.

    1996-01-01

    In conclusion, monolateral external fixation can be effectively utilized in the management of limb length discrepancy and angular deformity. This manuscript outlines the pertinent theory, application and problems important in these cases. When faced with specific congenital conditions the surgeon is encouraged to reference relevant literature that is more focused than the current paper. PMID:9129275

  14. Coupled external fixator and skin flap transposition for treatment of exposed and nonunion bone.

    PubMed

    Zhao, Yong-gang; Ding, Jing; Wang, Neng

    2011-02-01

    To discuss the effect of coupled external fixator and skin flap transposition on exposed and nonunion bones. The data of 12 cases of infected nonunion and exposed bone following open fracture treated in our hospital during the period of March 1998 to June 2008 were analysed. There were 10 male patients, 2 female patients, whose age were between 19-52 years and averaged 28 years. There were 10 tibial fractures and 2 femoral fractures. The course of diseases lasted for 12-39 months with the mean period of 19 months. All the cases were treated by the coupled external fixator and skin flap transposition. Primary healing were achieved in 10 cases and delayed healing in 2 cases in whom the tibia was exposed due to soft tissue defect and hence local flap transposition was performed. All the 12 cases had bony union within 6-12 months after operation with the average time of 8 months. They were followed up for 1-3 years and all fractures healed up with good function and no infection recurrence. The coupled external fixator and skin flap transposition therapy have shown optimal effects on treating infected, exposed and nonunion bones.

  15. Knee arthrodesis with circular external fixation.

    PubMed

    Garberina, M J; Fitch, R D; Hoffmann, E D; Hardaker, W T; Vail, T P; Scully, S P

    2001-01-01

    Knee arthrodesis can enable limb salvage in patients with disability secondary to trauma, infected total knee arthroplasty, pyarthrosis, and other complications. Historically, intramedullary nailing has resulted in the highest overall knee fusion rates. However, intramedullary nailing is relatively contraindicated in the presence of active infection. Nineteen patients who underwent knee arthrodesis with circular external fixation were studied retrospectively. Postoperative radiographs were evaluated for evidence of bony fusion, which was defined as trabecular bridging between the femur and tibia. Patients were interviewed and graded using the functional assessment portion of the Knee Society clinical rating system. Fusion was successful in 13 of 19 (68%) patients. Overall, patients spent an average of 4 months 8 days wearing the circular external fixator. Average time to radiographic and clinical evidence of arthrodesis (defined as lack of motion across the fusion site) was 4 months 18 days. No patient with successful fusion considered himself or herself housebound. All but one of these patients require some form of assistive device for ambulation. Complications occurred in 16 of 19 (84%) patients overall. Superficial pin tract infection (55%) and nonunion (32%) were the most common. Circular external fixation is an effective method for obtaining knee arthrodesis in patients who are not good candidates for intramedullary nailing.

  16. Treatment of open tibial shaft fracture with soft tissue and bone defect caused by aircraft bomb--case report.

    PubMed

    Golubović, Zoran; Vidić, Goran; Trenkić, Srbobran; Vukasinović, Zoran; Lesić, Aleksandar; Stojiljković, Predrag; Stevanović, Goran; Golubović, Ivan; Visnjić, Aleksandar; Najman, Stevo

    2010-01-01

    Aircraft bombs can cause severe orthopaedic injuries. Tibia shaft fractures caused by aircraft bombs are mostly comminuted and followed by bone defects, which makes the healing process extremely difficult and prone to numerous complications. The goal of this paper is to present the method of treatment and the end results of treatment of a serious open tibial fracture with soft and bone tissue defects resulting from aircraft bomb shrapnel wounds. A 26-year-old patient presented with a tibial fracture as the result of a cluster bomb shrapnel wound. He was treated applying the method of external bone fixation done two days after wounding, as well as of early coverage of the lower leg soft tissue defects done on the tenth day after the external fixation of the fracture. The external fixator was removed after five months, whereas the treatment was continued by means of functional plaster cast for another two months. The final functional result was good. Radical wound debridement, external bone fixation of the fracture, and early reconstruction of any soft tissue and bone defects are the main elements of the treatment of serious fractures.

  17. Stress Fractures of Tibia Treated with Ilizarov External Fixator.

    PubMed

    Górski, Radosław; Żarek, Sławomir; Modzelewski, Piotr; Górski, Ryszard; Małdyk, Paweł

    2016-08-30

    Stress fractures are the result of cyclic loading of the bone, which gradually becomes damaged. Most often they are treated by rest or plaster cast and, in rare cases, by internal fixation. There is little published data on initial reposition followed by stabilization with the Ilizarov apparatus in such fractures. Six patients were treated with an external fixator according to the Ilizarov method for a stress fracture of the tibia between 2007 and 2015. Three patients were initially treated conservatively. Due to increasing tibial deformation, they were qualified for surgical treatment with external stabilization. In the other patients, surgery was the first-line treatment. All patients demonstrated risk factors for a stress fracture. After the surgery, they fully loaded the operated limb. No patient developed malunion, nonunion, infection or venous thrombosis. The average time from the first operation to the removal of the external fixator was 19 weeks. Radiographic and clinical outcomes were satisfactory in all patients. 1. The Ilizarov method allows for successful stabilization of stress fractures of the tibia. 2. It may be a good alternative to internal stabilization, especially in patients with multiple comorbidities which affect bone quality and may impair soft tissue healing.

  18. Acute Pelvic Fractures: II. Principles of Management.

    PubMed

    Tile

    1996-05-01

    The past two decades have seen many advances in pelvic-trauma surgery. Provisional fixation of unstable pelvic-ring disruptions and open-book fractures with a pelvic clamp or an external frame with a supracondylar pin has proved markedly beneficial in the resuscitative phase of management. In the completely unstable pelvis, external clamps and frames can act only as provisional fixation and should be combined with skeletal traction. The traction pin is usually used only until a definitive form of stabilization can be applied to keep the pelvic ring in a reduced position. If the patient is too ill to allow operative intervention, the traction pin can remain in place with the external frame as definitive treatment. Symphyseal disruptions and medial ramus fractures should be plated at the time of laparotomy. Lateral ramus fractures can usually be controlled with external frames. A role has been suggested for percutaneous retrograde fixation of the superior pubic ramus; however, the benefits to be gained may not be enough to outweigh the serious risks of penetrating the hip, and this technique should therefore be used only by surgeons trained in its performance. The techniques for posterior fixation are becoming more standardized, but all still carry significant risks, especially to neurologic structures.

  19. Comparison of intramedullary nailing and external fixation knee arthrodesis for the infected knee replacement.

    PubMed

    Mabry, Tad M; Jacofsky, David J; Haidukewych, George J; Hanssen, Arlen D

    2007-11-01

    We analyzed knee arthrodesis for the infected total knee replacement (TKR) using two different fixation techniques. Patients undergoing knee arthrodesis for infected TKR were identified and rates of successful fusion and recurrence of infection were compared using Cox proportional hazard models. Eighty-five consecutive patients who underwent knee arthrodesis were followed until union, nonunion, amputation, or death. External fixation achieved successful fusion in 41 of 61 patients and was associated with a 4.9% rate of deep infection. Fusion was successful in 23 of 24 patients with intramedullary (IM) nailing and was associated with an 8.3% rate of deep infection. We observed similar fusion and infection rates with the two techniques. Thirty-four patients (40%) had complications. Knee arthrodesis remains a reasonable salvage alternative for the difficult infected TKR. Complication rates are high irrespective of the technique, and one must consider the risks of both nonunion and infection when choosing the fixation method in this setting. IM nailing appears to have a higher rate of successful union but a higher risk of recurrent infection when compared with external fixation knee arthrodesis. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  20. Periarticular locking plate vs intramedullary nail for tibiotalocalcaneal arthrodesis: a biomechanical investigation.

    PubMed

    Ohlson, Blake L; Shatby, Meena W; Parks, Brent G; White, Kacey L; Schon, Lew C

    2011-02-01

    Augmented retrograde intramedullary (IM) nail fixation was compared with augmented periarticular locking- plate fixation for tibiotalocalcaneal arthrodesis. Specimens in 10 matched pairs were randomly assigned to a fixation construct and loaded cyclically in dorsiflexion. The groups did not differ in initial or final stiffness, load to failure, or construct deformation. No correlation was found between bone mineral density and construct deformation for either group. A humeral locking plate may be a viable alternative to an IM nail for tibiotalocalcaneal fixation in cases not amenable to IM nailing.

  1. Computational modelling of ovine critical-sized tibial defects with implanted scaffolds and prediction of the safety of fixator removal.

    PubMed

    Doyle, Heather; Lohfeld, Stefan; Dürselen, Lutz; McHugh, Peter

    2015-04-01

    Computational model geometries of tibial defects with two types of implanted tissue engineering scaffolds, β-tricalcium phosphate (β-TCP) and poly-ε-caprolactone (PCL)/β-TCP, are constructed from µ-CT scan images of the real in vivo defects. Simulations of each defect under four-point bending and under simulated in vivo axial compressive loading are performed. The mechanical stability of each defect is analysed using stress distribution analysis. The results of this analysis highlights the influence of callus volume, and both scaffold volume and stiffness, on the load-bearing abilities of these defects. Clinically-used image-based methods to predict the safety of removing external fixation are evaluated for each defect. Comparison of these measures with the results of computational analyses indicates that care must be taken in the interpretation of these measures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Chronic elbow dislocation: a rare complication of tennis elbow surgery. Successful treatment by open reduction and external fixator.

    PubMed

    Degreef, I; De Smet, L

    2007-06-01

    A case is presented of chronic dislocation of the elbow after tennis elbow surgery combined with posterior interosseous nerve (PIN) release. An open reduction with repair of the collateral ligaments was performed. Postoperative rehabilitation involved the use of an articulated external fixator and there was a successful outcome. Possible causes of the dislocation are discussed.

  3. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.

    PubMed

    Kim, Joon-Woo; Oh, Chang-Wug; Oh, Jong-Keon; Kyung, Hee-Soo; Park, Kyeong-Hyeon; Kim, Hee-June; Jung, Jae-Wook; Jung, Young-Soo

    2017-06-01

    High-energy proximal tibial fractures often accompany compartment syndrome and are usually treated by fasciotomy with external fixation followed by secondary plating. However, the initial soft tissue injury may affect bony union, the fasciotomy incision or external fixator pin sites may lead to postoperative wound infections, and the staged procedure itself may adversely affect lower limb function. We assess the results of staged minimally invasive plate osteosynthesis (MIPO) for proximal tibial fractures with acute compartment syndrome. Twenty-eight patients with proximal tibial fractures accompanied by acute compartment syndrome who underwent staged MIPO and had a minimum of 12 months follow-up were enrolled. According to the AO/OTA classification, 6 were 41-A, 15 were 41-C, 2 were 42-A and 5 were 42-C fractures; this included 6 cases of open fractures. Immediate fasciotomy was performed once compartment syndrome was diagnosed and stabilization of the fracture followed using external fixation. After the soft tissue condition normalized, internal conversion with MIPO was done on an average of 37 days (range, 9-158) after index trauma. At the time of internal conversion, the external fixator pin site grades were 0 in 3 cases, 1 in 12 cases, 2 in 10 cases and 3 in 3 cases, as described by Dahl. Radiographic assessment of bony union and alignment and a functional assessment using the Knee Society Score and American Orthopedic Foot and Ankle Society (AOFAS) score were carried out. Twenty-six cases achieved primary bony union at an average of 18.5 weeks. Two cases of nonunion healed after autogenous bone grafting. The mean Knee Society Score and the AOFAS score were 95 and 95.3 respectively, at last follow-up. Complications included 1 case of osteomyelitis in a patient with a grade IIIC open fracture and 1 case of malunion caused by delayed MIPO due to poor wound conditions. Duration of external fixation and the external fixator pin site grade were not related to the occurrence of infection. Staged MIPO for proximal tibial fractures with acute compartment syndrome may achieve satisfactory bony union and functional results, while decreasing deep infections and soft tissue complications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. A comprehensive update on current fixation options for two-part proximal humerus fractures: a biomechanical investigation.

    PubMed

    Yoon, Richard S; Dziadosz, Daniel; Porter, David A; Frank, Matthew A; Smith, Wade R; Liporace, Frank A

    2014-03-01

    Recent advancements in implant technology offer updated options for surgical management that have been rapidly adopted into clinical practice. The objective of this study is to biomechanically test and compare the current fixation options available for surgical fixation of two-part proximal humerus fractures and establish load to failure and stiffness values. Sixteen match-paired (32 total) fresh-frozen, cadaveric specimens were randomized to receive 1 of 4 fixation constructs following creation of an AO/OTA Type 11A3 (two-part) proximal humerus fractures. Fixation constructs tested consisted of 3.5 mm fixed angle plate (3.5-FAP), 4.5 mm fixed angle plate (4.5-FAP), humeral intramedullary nail (IMN), and a humeral intramedullary nail with a fixed angle blade (IMN-FAB). Specimen bone density was measured to ensure no adequate, non-osteoporotic bone. Constructs were tested for stiffness and ultimate load to failure and compared via one-way ANOVA analysis with subsequent post hoc Tukey HSD multiple group comparison statistical analysis. The IMN-FAB construct was significantly stiffer than the 3.5-FAP construct (123.8 vs. 23.9, p<0.0001), the 4.5-FAP construct (123.8 vs. 33.3, p<0.0001) and the IMN construct (123.8 vs. 60.1, p=0.005). The IMN-FAB construct reported a significantly higher load to failure than the 3.5-FAB construct (4667.3 N vs. 1756.9 N, p<0.0001), and the 4.5-FAP construct (4667.3 N vs. 2829.4 N, p=0.019, Table 2). The IMN construct had a significantly higher load to failure than the 3.5-FAP construct (3946.8 vs. 1756.9, p=0.001, Table 2). Biomechanical testing of modern fixation options for two-part proximal humerus fracture exhibited that the stiffest and highest load to failure construct was the IMN-FAB followed by the IMN, 3.5-FAP and then the 4.5-FAP constructs. However, prospective clinical trials with longer-term follow-up are required for definitive assessment of the ideal fixation construct for surgical management of two-part proximal humerus fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Self-designed posterior atlas polyaxial lateral mass screw-plate fixation for unstable atlas fracture.

    PubMed

    He, Baorong; Yan, Liang; Zhao, Qinpeng; Chang, Zhen; Hao, Dingjun

    2014-12-01

    Most atlas fractures can be effectively treated nonoperatively with external immobilization unless there is an injury to the transverse atlantal ligament. Surgical stabilization is most commonly achieved using a posterior approach with fixation of C1-C2 or C0-C2, but these treatments usually result in loss of the normal motion of the C1-C2 and C0-C1 joints. To clinically validate feasibility, safety, and value of open reduction and fixation using an atlas polyaxial lateral mass screw-plate construct in unstable atlas fractures. Retrospective review of patients who sustained unstable atlas fractures treated with polyaxial lateral mass screw-plate construct. Twenty-two patients with unstable atlas fractures who underwent posterior atlas polyaxial lateral mass screw-plate fixation were analyzed. Visual analog scale, neurologic status, and radiographs for fusion. From January 2011 to September 2012, 22 patients with unstable atlas fractures were treated with this technique. Patients' charts and radiographs were reviewed. Bone fusion, internal fixation placement, and integrity of spinal cord and vertebral arteries were assessed via intraoperative and follow-up imaging. Neurologic function, range of motion, and pain levels were assessed clinically on follow-up. All patients were followed up from 12 to 32 months, with an average of 22.5±18.0 months. A total of 22 plates were placed, and all 44 screws were inserted into the atlas lateral masses. The mean duration of the procedure was 86 minutes, and the average estimated blood loss was 120 mL. Computed tomography scans 9 months after surgery confirmed that fusion was achieved in all cases. There was no screw or plate loosening or breakage in any patient. All patients had well-preserved range of motion. No vascular or neurologic complication was noted, and all patients had a good clinical outcome. An open reduction and posterior internal fixation with atlas polyaxial lateral mass screw-plate is a safe and effective surgical option in the treatment of unstable atlas fractures. This technique can provide immediate reduction and preserve C1-C2 motion. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. [Manipulative reduction and plaster external fixation for the treatment of the scaphoid fracture and perilunate dislocation].

    PubMed

    Zhang, Xin; Wei, Qiang; Ji, Fang; Tong, Da-Ke; Tang, Hao; Zhang, Hao; Yu, Jin-Guo; Yang, Ji-Dong; Cui, Rui; Huo, Ning-Ning

    2018-05-25

    To investigate the efficacy and complications of manual reduction and external fixation for the treatment of scaphoid fractures and perilunate dislocations. From January 2009 to January 2013, 43 patients suffered from scaphoid fractures and perilunate dislocations were retrospective analyzed. Among them, 17 cases were treated with manipulative reduction and plaster external fixation as conservation group including 10 males and 7 females, the other 26 cases were treated with application of surgical as operation group including 15 males and 11 females. The clinical effects were assessed by Cooney function score, radiological analysis and observation of complications. All patients were followed up for(45.00±8.72) months ranging from 36 to 60 months. At the final follow-up, the Cooney score of wrist function was 88.53±4.24 in conservation group and 89.58±4.59in operation group( t= 0.455, P >0.05). During the follow-up, 4 patients were found scaphoid avascular necrosis in the imaging performance in the conservation group(χ²=4.32, P <0.05). The difference of other complications between two groups was not statistically significant( P >0.05). For patients suffered from the scaphoid fractures and perilunate dislocation, the early manipulative reduction and plaster external fixation after injury as soon as possible is necessary. Maintaining a satisfactory reduction and reliable fixation at the same time can lead to good treatment effect and there's no weakness compared to surgical treatment. But there was an increase in danger of complications. The key of conservative treatment lies in early diagnosis and maintenance of reduction, reliable fixation, and timely and appropriate functional exercise. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  7. Treatment of open tibial fracture with bone defect caused by high velocity missiles: a case report.

    PubMed

    Golubović, Zoran; Vukajinović, Zoran; Stojiljković, Predrag; Golubović, Ivan; Visnjić, Aleksandar; Radovanović, Zoran; Najman, Stevo

    2013-01-01

    Tibia fracture caused by high velocity missiles is mostly comminuted and followed by bone defect which makes their healing process extremely difficult and prone to numerous complications. A 34-year-old male was wounded at close range by a semi-automatic gun missile. He was wounded in the distal area of the left tibia and suffered a massive defect of the bone and soft tissue. After the primary treatment of the wound, the fracture was stabilized with an external fixator type Mitkovic, with convergent orientation of the pins. The wound in the medial region of the tibia was closed with the secondary stitch, whereas the wound in the lateral area was closed with the skin transplant after Thiersch. Due to massive bone defect in the area of the rifle-missile wound six months after injury, a medical team placed a reconstructive external skeletal fixator type Mitkovic and performed corticotomy in the proximal metaphyseal area of the tibia. By the method of bone transport (distractive osteogenesis), the bone defect of the tibia was replaced. After the fracture healing seven months from the secondary surgery, the fixator was removed and the patient was referred to physical therapy. Surgical treatment of wounds, external fixation, performing necessary debridement, adequate antibiotic treatment and soft and bone tissue reconstruction are essential in achieving good results in patients with the open tibial fracture with bone defect caused by high velocity missiles. Reconstruction of bone defect can be successfully treated by reconstructive external fixator Mitkovic.

  8. Source of the slippage in the universal joints of the Hoffmann external fixator.

    PubMed

    Drijber, F L; Finlay, J B; Moroz, T K; Rorabeck, C H

    1990-01-01

    An investigation was conducted to determine what improvements in the resistance to slippage could be obtained in selected interfaces (rod/clip torsional, cheek/bowl and cheek/clip) of the Hoffmann external fixator. The modification involved changing the standard wing-nut clamp for a bolt with a thread of 7 mm and a 1 mm pitch and placing an FAG 28-303 thrust-bearing (needle roller and cage assembly) between the bolt and the cheek. The results showed a significant improvement in the slippage values of all interfaces; increases of approximately six times were obtained at all torque values of the wing-nut clamp or fastener tested. Such improvements would markedly increase the reliability of external fixation systems and thus reduce the incidence of loss-of-reduction of fracture due to slippage of the universal joint.

  9. Advantages and disadvantages of pinless external fixation.

    PubMed

    Thomas, S R; Giele, H; Simpson, A H

    2000-12-01

    The AO pinless external fixator (PEF) uses trocar tipped clamps to grip the outer tibial cortex rather than pins to transfix it. Its main advantage is to avoid further contamination of the medullary canal in open tibial fractures where a nail may subsequently be used. We tested the anatomical safety of this device and its effect on plastic surgical procedures compared with a standard unilateral external fixator (UEF).The PEF and UEF were placed on two amputated limbs which were then dissected. Structures at risk were traced on ten cadaver limbs. We found that important anatomical structures were endangered by the PEF and that safe zones could not always be defined. The UEF avoided these structures. Plastic surgical approaches were made more difficult by the PEF which imposed limitations on local flap design and endangered the arterial perforators which supply them. We conclude that safety is compromised by the PEF because margins for error are small. It poses additional problems in soft tissue reconstruction and highlights the need for co-operation between plastic surgical and orthopaedic teams in choice of fixation device.

  10. Vacuum sealing drainage therapy in the presence of an external fixation device

    PubMed Central

    Sun, Dahui; Ju, Weina; Wang, Tiejun; Yu, Tiecheng; Qi, Baochang

    2016-01-01

    Abstract Rationale: Vacuum sealing drainage (VSD) is widely utilized for treating traumatic wounds. Patient concerns: It is particularly difficult and time consuming to use in combination with an external fixator. Diagnoses: This is because the hardware or pins used for fixation interfere with maintaining a seal, resulting in poor adhesion and subsequent air leakage. Interventions: To resolve this problem, we have devised a new method for sealing the wound dressing, while maintaining the required vacuum.When using this technique, a rubber strip is wrapped around each pin in 3 circles outside the plastic drape, and then tightly tied. Outcomes: After completing this procedure, a vacuum is obtained, and any air leakage stops. We employed this technique to treat a cohort of patients in our department over a period of two years, and obtained good healing of soft tissue without air leakage, as well as good clinical outcomes. Lessons: We have observed that patients treated with this method experienced good clinical outcomes without air leakage, and we recommend its use in treating cases where an external fixation device is present. PMID:27861393

  11. Fracture healing in mice under controlled rigid and flexible conditions using an adjustable external fixator.

    PubMed

    Röntgen, Viktoria; Blakytny, Robert; Matthys, Romano; Landauer, Mario; Wehner, Tim; Göckelmann, Melanie; Jermendy, Philipp; Amling, Michael; Schinke, Thorsten; Claes, Lutz; Ignatius, Anita

    2010-11-01

    Mice are increasingly used to investigate mechanobiology in fracture healing. The need exists for standardized models allowing for adjustment of the mechanical conditions in the fracture gap. We introduced such a model using rigid and flexible external fixators with considerably different stiffness (axial stiffnesses of 18.1 and 0.82 N/mm, respectively). Both fixators were used to stabilize a 0.5 mm osteotomy gap in the femur of C57BL/6 mice (each n = 8). Three-point bending tests, µCT, and histomorphometry demonstrated a different healing pattern after 21 days. Both fixations induced callus formation with a mixture of intramembranous and enchondral ossification. Under flexible conditions, the bending stiffness of the callus was significantly reduced, and a larger but qualitatively inferior callus with a significantly lower fraction of bone but a higher fraction of cartilage and soft tissue was formed. Monitoring of the animal movement and the ground reaction forces demonstrated physiological loading with no significant differences between the groups, suggesting that the differences in healing were not based on a different loading behavior. In summary, flexible external fracture fixation of the mouse femur led to delayed fracture healing in comparison to a more rigid situation. © 2010 Orthopaedic Research Society.

  12. [Safety evaluation of secondary conversion from external fixation to internal fixation for open tibia fractures].

    PubMed

    Liu, Xi; Cen, Shiqiang; Xiang, Zhou; Zhong, Gang; Yi, Min; Fang, Yue; Liu, Lei; Huang, Fuguo

    2017-06-01

    To evaluate the safety of conversion from external fixation to internal fixation for open tibia fractures. Between January 2010 and December 2014, 94 patients (98 limbs) with open tibia fractures were initially treated with external fixators at the first stage, and the clinical data were retrospectively analyzed. In 29 cases (31 limbs), the external fixators were changed to internal fixation for discomfort, pin tract response, Schantz pin loosening, delayed union or non-union after complete wound healing and normal or close to normal levels of erythrocyte sedimentation rate (ESR), C reactive protein (CRP), and the leucocyte count as well as the neutrophil ratio (trial group); in 65 cases (67 limbs), the external fixators were used as the ultimate treatment in the control group. There was no significant difference in gender, age, side of the limbs, interval from injury to the first debridement, initial pathogenic bacteria, the limbs that skin grafting or flap transferring for skin and soft tissue defect between the two groups ( P >0.05). The incidence of Gustilo type III fractures in the control group was significantly higher than that in the trial group ( P =0.000). The overall incidence of infection was calculated respectively in the two groups. The incidence of infection according to different fracture types and whether skin grafting or flap transferring was compared between the two groups. The information of the pathogenic bacteria was recorded in the infected patients, and it was compared with the results of the initial culture. The incidence of infection in the patients of the trial group using different internal fixation instruments was recorded. The overall incidences of infection for the trial and control groups were 9.7% (3/31) and 9.0% (6/67) respectively, showing no significant difference ( χ 2 =0.013, P =0.909). No infection occurred in Gustilo type I and type II patients. The incidence of infection for Gustilo type IIIA patients in the trial group and the control group were 14.3% (1/7) and 6.3% (2/32) respectively, showing no significant difference ( χ 2 =0.509, P =0.476); the incidence of infection for type IIIB patients in the two groups were 50.0% (2/4) and 14.3% (2/14) respectively, showing no significant difference ( χ 2 =2.168, P =0.141); and the incidence of infection for type IIIC patients in the two groups were 0 and 16.7% (2/12) respectively, showing no significant difference ( χ 2 =0.361, P =0.548). Of all the infected limbs, only 1 limb in the trial group had the same Staphylococcus Aureus as the result of the initial culture. In the patients who underwent skin grafting or flap transferring, the incidence of infection in the trial and control groups were 33.3% (2/6) and 13.3% (2/15) respectively, showing no significant difference ( χ 2 =1.059, P =0.303). After conversion to internal fixation, no infection occurred in the cases that fixed with nails (11 limbs), and infection occurred in 4 of 20 limbs that fixed with plates, with an incidence of infection of 20%. Conversion from external fixation to internal fixation for open tibia fractures is safe in most cases. However, for open tibia fractures with extensive and severe soft tissue injury, especially Gustilo type III patients who achieved wound heal after flap transfer or skin grafting, the choice of secondary conversion to internal fixation should carried out cautiously. Careful pre-operative evaluation of soft tissue status, cautious choice of fixation instrument and meticulous intra-operative soft tissue protection are essential for its safety.

  13. Mini-Fragment Fixation Is Equivalent to Bicortical Screw Fixation for Horizontal Medial Malleolus Fractures.

    PubMed

    Wegner, Adam M; Wolinsky, Philip R; Robbins, Michael A; Garcia, Tanya C; Amanatullah, Derek F

    2018-05-01

    Horizontal fractures of the medial malleolus occur through application of valgus or abduction force through the ankle that creates a tension failure of the medial malleolus. The authors hypothesize that mini-fragment T-plates may offer improved fixation, but the optimal fixation construct for these fractures remains unclear. Forty synthetic distal tibiae with identical osteotomies were randomized into 4 fixation constructs: (1) two parallel unicortical cancellous screws; (2) two parallel bicortical cortical screws; (3) a contoured mini-fragment T-plate with 2 unicortical screws in the fragment and 2 bicortical screws in the shaft; and (4) a contoured mini-fragment T-plate with 2 bicortical screws in the fragment and 2 unicortical screws in the shaft. Specimens were subjected to offset axial tension loading on a servohydraulic testing system and tracked using high-resolution video. Failure was defined as 2 mm of articular displacement. Analysis of variance followed by a Tukey-Kramer post hoc test was used to assess for differences between groups, with significance defined as P<.05. The mean stiffness (±SD) values of both mini-fragment T-plate constructs (239±83 N/mm and 190±37 N/mm) and the bicortical screw construct (240±17 N/mm) were not statistically different. The mean stiffness values of both mini-fragment T-plate constructs and the bicortical screw construct were higher than that of a parallel unicortical screw construct (102±20 N/mm). Contoured T-plate constructs provide stiffer initial fixation than a unicortical cancellous screw construct. The T-plate is biomechanically equivalent to a bicortical screw construct, but may be superior in capturing small fragments of bone. [Orthopedics. 2018; 41(3):e395-e399.]. Copyright 2018, SLACK Incorporated.

  14. Medial malleolar fractures: a biomechanical study of fixation techniques.

    PubMed

    Fowler, T Ty; Pugh, Kevin J; Litsky, Alan S; Taylor, Benjamin C; French, Bruce G

    2011-08-08

    Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO group recommends tension-band fixation of small avulsion type fractures of the medial malleolus that are unacceptable for screw fixation. A well-documented complication of this technique is prominent symptomatic implants and secondary surgery for implant removal. Replacing stainless steel 18-gauge wire with FiberWire suture could theoretically decrease symptomatic implants. Therefore, a second goal was to biomechanically compare these 2 tension-band constructs. Using a tibial Sawbones model, 2 bicortical screws were compared with 2 unicortical cancellous screws on a servohydraulic test frame in offset axial, transverse, and tension loading. Second, tension-band fixation using stainless steel wire was compared with FiberWire under tensile loads. Bicortical screw fixation was statistically the stiffest construct under tension loading conditions compared to unicortical screw fixation and tension-band techniques with FiberWire or stainless steel wire. In fact, unicortical screw fixation had only 10% of the stiffness as demonstrated in the bicortical technique. In a direct comparison, tension-band fixation using stainless steel wire was statistically stiffer than the FiberWire construct. Copyright 2011, SLACK Incorporated.

  15. The Colorado Humanitarian Surgical Skills Workshop: A Cadaver-Based Workshop to Prepare Residents for Surgery in Austere Settings.

    PubMed

    Lin, Yihan; Mukhopadhyay, Swagoto; Meguid, Robert A; Kuwayama, David P

    Interest in humanitarian surgery is high among surgical and obstetric residents. The Colorado Humanitarian Surgical Skills Workshop is an annual 2-day course exposing senior residents to surgical techniques essential in low- and middle-income countries but not traditionally taught in US residencies. We evaluated the course's ability to foster resident comfort, knowledge, and competence in these skills. The cohort of course participants was studied prospectively. Participants attended didactic sessions followed by skills sessions using cadavers. Sample areas of focus included general surgery (mesh-free hernia repair), orthopedics (powerless external fixation), and neurosurgery (powerless craniotomy). Before and after the course, participants answered a questionnaire assessing confidence with taught skills; took a knowledge-based test composed of multiple choice and open-ended questions; and participated in a manual skills test of tibial external fixation. The Center for Surgical Innovation, University of Colorado School of Medicine. A total of 12 residents (11 general surgical and 1 obstetric) from ten US institutions. After the course, participants perceived increased confidence in performing all 27 taught procedures and ability to practice in low- and middle-income countries. In knowledge-based testing, 10 of 12 residents demonstrated improvement on multiple choice questioning and 9 of 12 residents demonstrated improvement on open-ended questioning with structured scoring. In manual skills testing, all external fixator constructs demonstrated objective improvement on structured scoring and subjective improvement on stability assessment. For senior residents interested in humanitarian surgery, a combination of skills-focused teaching and manual practice led to self-perceived and objective improvement in relevant surgical knowledge and skills. The Colorado Humanitarian Surgical Skills Workshop represents an effective model for transmitting essential surgical principles and techniques of value in low-resource settings. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  16. Accuracy of a hexapod parallel robot kinematics based external fixator.

    PubMed

    Faschingbauer, Maximilian; Heuer, Hinrich J D; Seide, Klaus; Wendlandt, Robert; Münch, Matthias; Jürgens, Christian; Kirchner, Rainer

    2015-12-01

    Different hexapod-based external fixators are increasingly used to treat bone deformities and fractures. Accuracy has not been measured sufficiently for all models. An infrared tracking system was applied to measure positioning maneuvers with a motorized Precision Hexapod® fixator, detecting three-dimensional positions of reflective balls mounted in an L-arrangement on the fixator, simulating bone directions. By omitting one dimension of the coordinates, projections were simulated as if measured on standard radiographs. Accuracy was calculated as the absolute difference between targeted and measured positioning values. In 149 positioning maneuvers, the median values for positioning accuracy of translations and rotations (torsions/angulations) were below 0.3 mm and 0.2° with quartiles ranging from -0.5 mm to 0.5 mm and -1.0° to 0.9°, respectively. The experimental setup was found to be precise and reliable. It can be applied to compare different hexapod-based fixators. Accuracy of the investigated hexapod system was high. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Posterior cervical fixation for fracture and degenerative disc disease.

    PubMed

    An, H S; Coppes, M A

    1997-02-01

    There are numerous newer techniques that have been developed for the internal fixation of the cervical spine in recent years. Wiring techniques are still appropriate for posterior stabilization of the cervical spine. The halo vest is still widely used for the conservative management of cervical fractures and for postoperative external immobilization. The authors stress that the surgical indications for more modern rigid implants should be adhered to strictly. These implants also should be selected by weighing their advantages versus potential risks. In the upper cervical spine, the surgeon may choose traditional wiring methods and newer C1-C2 screw fixation, occipitocervical plate fixation. For the lower cervical spine, triple wiring technique or lateral mass plating may be used. The surgeon must choose an appropriate device based on the mechanism of injury, pathoanatomy of the lesion, and familiarity with the device, keeping in mind that the goals of internal fixation are stabilization, reduction and maintenance of alignment, early rehabilitation and perhaps enhancement of fusion rates, and avoidance of use of an external halo vest.

  18. Successful correction of tibial bone deformity through multiple surgical procedures, liquid nitrogen-pretreated bone tumor autograft, three-dimensional external fixation, and internal fixation in a patient with primary osteosarcoma: a case report.

    PubMed

    Takeuchi, Akihiko; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Watanabe, Koji; Miwa, Shinji; Tsuchiya, Hiroyuki

    2015-12-07

    In a previous report, we described a method of reconstruction using tumor-bearing autograft treated by liquid nitrogen for malignant bone tumor. Here we present the first case of bone deformity correction following a tumor-bearing frozen autograft via three-dimensional computerized reconstruction after multiple surgeries. A 16-year-old female student presented with pain in the left lower leg and was diagnosed with a low-grade central tibial osteosarcoma. Surgical bone reconstruction was performed using a tumor-bearing frozen autograft. Bone union was achieved at 7 months after the first surgical procedure. However, local tumor recurrence and lung metastases occurred 2 years later, at which time a second surgical procedure was performed. Five years later, the patient developed a 19° varus deformity and underwent a third surgical procedure, during which an osteotomy was performed using the Taylor Spatial Frame three-dimensional external fixation technique. A fourth corrective surgical procedure was performed in which internal fixation was achieved with a locking plate. Two years later, and 10 years after the initial diagnosis of tibial osteosarcoma, the bone deformity was completely corrected, and the patient's limb function was good. We present the first report in which a bone deformity due to a primary osteosarcoma was corrected using a tumor-bearing frozen autograft, followed by multiple corrective surgical procedures that included osteotomy, three-dimensional external fixation, and internal fixation.

  19. [Arthrodesis of the infected ankle joint: results with the Ilizarov external fixator].

    PubMed

    Gessmann, J; Ozokyay, L; Fehmer, T; Muhr, G; Seybold, D

    2011-04-01

    The treatment of severe bacterial infections of the ankle joint is difficult and complex. In the case of a chronic infection with destruction of the ankle joint, a tibiotalar arthrodesis with external fixation is the treatment of choice. In this study the results of ankle arthrodesis due to bacterial infection using the Ilizarov external fixator are presented. Between 2001 and 2004 37 patients (10 female, 27 male, mean age 58 years) were treated with a tibiotalar arthrodesis using the Ilizarov fixator. All patients had a confirmed infection in the course of their disease. Active infection was present in 20 patients at the time of the operation. Most secondary ankle arthritides (81 %) were caused post-traumatically after various internal fixation procedures. Previous ankle arthrodeses were tried in 14 cases (12 cases with internal fixation, two cases with external monolateral fixation). Patients were treated with a four-ring Ilizarov frame (in two cases with a five-ring frame) and stainless steel wires. All patients could be included at a mean follow-up of 46 (12-49) months. A modified AOFAS score was used for the functional outcome. The operation took 141 minutes at an average ranging from 90 to 252 minutes. The inpatient treatment lasted between 10 and 63 days (mean 26 days). The time spent in the fixator was 116.7 (69-245) days. All patients were mobilised under full weight bearing with the external fixator. Surgical revision was necessary in 13 patients: four patients needed wound revisions due to ongoing infection, six patients needed wire exchange due to deep infection in three cases and wire breakage in three cases, one patient needed additional wires because of an initially instable frame configuration and two patients needed secondary skin grafting. Bony consolidation was achieved in 32 patients (86.5 %). With a re-arthrodesis performed in four patients using the Ilizarov fixator, the overall fusion rate was 94.6 %. Infection was persistent in two cases with one solid ankle fusion and one ankle pseudarthrosis. At the time of follow-up 35 patients were able to walk under full weight loading with orthopaedic shoe modifications, four patients needed support of a cane and three patients wore an ankle-foot orthesis. The two patients with persistent pseudarthrosis were mobilised in a lower-leg orthesis after declining another surgical revision. The positioning of the hindfoot showed in seven cases an equinus of 10°, in one case a varus of 10° and in two cases a valgus positioning of 10°. A plantigrade foot positioning or with minimal degrees of deviation could be achieved in all other cases. The modified AOFAS score at the time of the follow-up examination ranged from 19 to 86 with an average score of 67.9 points. All patients except three were satisfied or rather satisfied with the treatment procedure and its results. The Ilizarov external fixator is a safe method for ankle fusion in cases of infection. The advances are a possible application at acute infection and immediate mobilisation at full weight bearing. However, it remains a time-consuming and stressful procedure for the patient. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Mechanical testing of a steel-reinforced epoxy resin bar and clamp for external skeletal fixation of long-bone fractures in cats.

    PubMed

    Leitch, B J; Worth, A J

    2018-05-01

    To provide veterinarians with confidence when using a commercially available epoxy resin in external skeletal fixators (ESF), testing was conducted to determine exothermia during curing of the epoxy resin compared to polymethylmethacrylate (PMMA), the hardness of the epoxy resin as a bar over 16 weeks, and the strength of the epoxy resin bar compared with metal clamps in similarly constructed Type 1a ESF constructs simulating the repair of feline long bone fractures. Exothermia of the epoxy resin during curing was tested against PMMA with surface temperatures recorded over the first 15 minutes of curing, using four samples of each product. The hardness of 90 identical epoxy resin bars was tested by subjecting them to cyclic loads (1,000 cycles of 20.5 N, every 7 days) over a 16-week period and impact testing 10 bars every 2 weeks. Ten bars that were not subjected to cyclic loads were impact tested at 0 weeks and another 10 at 16 weeks. Strength of the epoxy resin product, as a bar and clamp composite, was tested against metal SK and Kirschner-Ehmer (KE) clamps and bars in Type 1a, tied-in intramedullary pin, ESF constructs with either 90° or 75° pin placement, subjected to compressive and bending loads to 75 N. The maximum temperature during curing of the epoxy resin (min 39.8, max 43.0)°C was less than the PMMA (min 85.2, max 98.5)°C (p<0.001). There was no change in hardness of the epoxy resin bars over the 16 weeks of cyclic loading (p=0.58). There were no differences between the median strength of the epoxy resin, SK or KE ESF constructs in compression or bending when tested to 75 N (p>0.05). Stiffness of constructs with 75° pin placement was greater for SK than epoxy resin constructs in compression (p=0.046), and was greater for KE than epoxy resin constructs in bending (p=0.033). The epoxy resin tested was found to be less exothermic than PMMA; bars made from the epoxy resin showed durability over an expected fracture healing timeframe and had mechanical strength characteristics comparable to metal bar and clamp ESF constructs. The epoxy resin ESF construct tested in this study can be considered a suitable replacement for SK or KE ESF constructs in the treatment of feline long-bone fractures, in terms of mechanical strength.

  1. Operative stabilization of open long bone fractures: A tropical tertiary hospital experience

    PubMed Central

    Ifesanya, Adeleke O.; Alonge, Temitope O.

    2012-01-01

    Background: Operative treatment of open fractures in our environment is fraught with problems of availability of theater space, appropriate hardware, and instrumentation such that high complication rates may be expected. Materials and Methods: We evaluated all open long bone fractures operatively stabilized at our center to determine the outcome of the various treatment modalities as well as the determinant factors. Result: A total of 160 patients with 171 fractures treated between December 1995 and December 2008 were studied. There were twice as many males; mean age was 35.0 years. About half were open tibia fractures. Gustilo IIIa and IIIb fractures each accounted for 56 cases (45.2%). Fifty-three percent were stabilized within the first week of injury. Interval between injury and operative fixation averaged 11.1 days. Anderson-Hutchin's technique was employed in 27 cases (21.8%), external fixation in 21 (16.9%), plate osteosynthesis in 50 (40.3%), and intramedullary nail 15 cases (12.1%). Mean time to union was 24.7 weeks. Fifty-two complications occurred in 50 fractures (40.3%) with joint stiffness and chronic osteomyelitis each accounting for a quarter of the complications. Union was delayed in grade IIIb open fractures and those fractures treated with external fixation. Conclusion: A significant proportion of open long bone fractures we operatively treated were severe. Severe open fractures (type IIIb) with concomitant stabilization using external fixation delayed fracture union. While we recommend intramedullary devices for open fractures, in our setting where locking nails are not readily available, external fixation remains the safest choice of skeletal stabilization particularly when contamination is high. PMID:23271839

  2. Comparing Different Surgical Techniques for Addressing the Posterior Malleolus in Supination External Rotation Ankle Fractures and the Need for Syndesmotic Screw Fixation.

    PubMed

    Li, Mengnai; Collier, Rachel C; Hill, Brian W; Slinkard, Nathaniel; Ly, Thuan V

    Trimalleolar ankle fractures are unstable injuries with possible syndesmotic disruption. Recent data have described inherent morbidity associated with screw fixation of the syndesmosis, including the potential for malreduction, hardware irritation, and post-traumatic arthritis. The posterior malleolus is an important soft tissue attachment for the posterior inferior syndesmosis ligament. We hypothesized that fixation of a sizable posterior malleolar (PM) fracture in supination external rotation type IV (SER IV) ankle fractures would act to stabilize the syndesmosis and minimize or eliminate the need for trans-syndesmotic fixation. A retrospective review of trimalleolar ankle fractures surgically treated from October 2006 to April of 2011 was performed. A total of 143 trimalleolar ankle fractures were identified, and 97 were classified as SER IV. Of the 97 patients, 74 (76.3%) had a sizable PM fragment. Syndesmotic fixation was required in 7 of 34 (20%) and 27 of 40 (68%), respectively, when the PM was fixed versus not fixed (p = .0002). When the PM was indirectly reduced using an anterior to posterior screw, 7 of 15 patients (46.7%) required syndesmotic fixation compared with none of 19 patients when the PM fragment was fixated with direct posterior lateral plate fixation (p = .0012). Fixation of the PM fracture in SER IV ankle fractures can restore syndesmotic stability and, thus, lower the rate of syndesmotic fixation. We found that fixation of a sizable PM fragment in SER IV or equivalent injuries through posterolateral plating can eliminate the need for syndesmotic screw fixation. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Tibial Plateau Fractures in Elderly Patients

    PubMed Central

    Vemulapalli, Krishna C.; Gary, Joshua L.; Donegan, Derek J.

    2016-01-01

    Tibial plateau fractures are common in the elderly population following a low-energy mechanism. Initial evaluation includes an assessment of the soft tissues and surrounding ligaments. Most fractures involve articular depression leading to joint incongruity. Treatment of these fractures may be complicated by osteoporosis, osteoarthritis, and medical comorbidities. Optimal reconstruction should restore the mechanical axis, provide a stable construct for mobilization, and reestablish articular congruity. This is accomplished through a variety of internal or external fixation techniques or with acute arthroplasty. Regardless of the treatment modality, particular focus on preservation and maintenance of the soft tissue envelope is paramount. PMID:27551570

  4. The management of tibial pilon fractures with the Ilizarov fixator: The role of ankle arthroscopy.

    PubMed

    El-Mowafi, Hani; El-Hawary, Ahmed; Kandil, Yasser

    2015-12-01

    Pilon fractures usually result from high energy trauma, and are commonly associated with extensive soft tissue damage which prevents the use of open reduction and internal fixation. This study was designed to evaluate the use of the Ilizarov external fixator in the treatment of pilon fractures of the ankle, and to determine whether arthroscopy of the ankle could improve the outcome. From February 2011 to May 2013 a total of 23 patients with unilateral closed pilon fractures were divided into two groups treated with and without arthroscopy during fixation with the Ilizarov external fixator. The fractures were classified according to the AO Rüdi and Allgőwer classification. Follow up ranged from 10 to 37 months with a mean of 18 months. All cases were evaluated at follow up by the AOFAS and the Bone et al. grading system. According to Bone et al. there were 3 cases excellent, 4 cases good, 2 cases fair, and 2 cases poor in Group A (without arthroscopy), whereas there were 4 cases excellent, 6 cases good, 2 cases fair in Group B (with arthroscopy). The AOFAS score for Group A was 77.8±5.8, and for Group B was 78.4±6.9. We concluded that the Ilizarov external fixator is an excellent method in treating pilon fractures as it minimizes the need for extensive surgery. We also conclude that the use of arthroscopy during pilon fracture fixation did not add statistically significant improvement to our results and it needs longer term investigation to assess its advantage - if any - to the final outcome. level 2. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Clinical results of resection arthrodesis by triangular external fixation for posttraumatic arthrosis of the ankle joint in 89 cases.

    PubMed

    Kiene, J; Schulz, Arndt P; Hillbricht, S; Jürgens, Ch; Paech, A

    2009-01-28

    The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations.

  6. Clinical results of resection arthrodesis by triangular external fixation for posttraumatic arthrosis of the ankle joint in 89 cases

    PubMed Central

    2009-01-01

    The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. Patients and Methods From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Results: Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Conclusion Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations. PMID:19258207

  7. Biomechanical comparison of supraacetabular external fixation and anterior pelvic bridge plating.

    PubMed

    Çavuşoğlu, Ali Turgay; Erbay, Fatma Kübra; Özsoy, Mehmet Hakan; Demir, Teyfik

    2017-10-01

    Unstable pelvic ring injuries are complex and risky injuries due to high morbidity and mortality. Although anterior pelvic external fixator is a suitable method for rapid stabilization of an injured pelvic ring, due to some disadvantages such as high complication rate, nerve damage, and difficulties of patient's mobility and comfort, there has recently been increased searching for alternative methods for stabilization of the pelvic ring. Pubic symphysis zone freely moves in pelvic models. This study aims to evaluate the biomechanical stability of anterior pelvic bridge plating and compare it with supraacetabular external fixators in an untreated unstable pelvic fracture model. Samples were loaded statically with 2-mm/min loading rate in single leg standing position. Maximum load was 2.3 kN. When loading the samples, photographs were taken continuously. Stiffness values were calculated from the load displacement curves. Some reference parameters were described and were measured from unloaded and 2.3-kN-loaded photographs of the test. The mean stiffness values were 491.14 ± 52.22, 478.55 ± 41.44, and 470.25 ± 44.51 N/mm for anterior pelvic bridge plating group, supraacetabular external fixator group, and Control group, respectively. According to the measured parameters from photographs, the mean displacement at the pubic symphysis was 4.7 ± 0.32, 15.8 ± 2.01, and 18.2 ± 0.47 mm for anterior pelvic bridge plating, supraacetabular external fixator, and Control group, respectively. The highest displacement in the pubic symphysis was found in Control group, and minimum displacement was observed in anterior pelvic bridge plating group. When the perpendicular distance between the right and left lower end of ischium was examined, it was observed that displacement was minimum in anterior pelvic bridge plating group compared to other two groups, regarding to the high stability of pubic symphysis. In conclusion, this study revealed superiority of anterior subcutaneous plate fixation with biomechanical results.

  8. Releasing the circumferential fixation of the medial meniscus does not affect its kinematics.

    PubMed

    Vrancken, A C T; van Tienen, T G; Hannink, G; Janssen, D; Verdonschot, N; Buma, P

    2014-12-01

    Meniscal functioning depends on the fixation between the meniscal horns and the surrounding tissues. It is unknown, however, whether the integration between the outer circumference of the medial meniscus and the knee capsule/medial collateral ligament also influences the biomechanical behavior of the meniscus. Therefore, we aimed to determine whether detaching and resuturing the circumferential fixation of the medial meniscus influence its kinematic pattern. Human cadaveric knee joints were flexed (0°-30°-60°-90°) in a knee loading rig, in neutral orientation and under internal and external tibial torques. Roentgen stereophotogrammetric analysis was used to determine the motion of the meniscus in anteroposterior (AP) and mediolateral (ML) directions. Three fixation conditions were evaluated: (I) intact, (II) detached and (III) resutured. Detaching and resuturing the circumferential fixation did not alter the meniscal motion pattern in either the AP or ML direction. Applying an additional internal tibial torque caused the medial meniscus to move slightly anteriorly, and an external torque caused a little posterior translation with respect to the neutral situation. These patterns did not change when the circumferential fixation condition was altered. This study demonstrated that the motion pattern of the medial meniscus is independent of its fixation to the knee capsule and medial collateral ligament. The outcomes of this study can be deployed to design the fixation strategy of a permanent meniscus prosthesis. As peripheral fixation is a complicated step during meniscal replacement, the surgical procedure is considerably simplified when non-resorbable implants do not require circumferential fixation. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Treatment of unstable intraarticular fracture of distal radius: POP casting with external fixation.

    PubMed

    ur Rahman, Obaid; Khan, Mohammad Qadeem; Rasheed, Haroon; Ahmad, Saleem

    2012-04-01

    To compare radiological and functional outcome of external fixation and distraction with conservative Plaster of Paris (POP) cast for unstable intra-articular fractures of the distal radius. The study was conducted on 60 patients with unstable intra-articular fracture of distal radius who reported to emergency or outpatient Orthopaedic Surgery department of Benazir Bhutto Hospital, Rawalpindi, between March and August 2007. They were divided into two equal groups: Group A and Group B, treated by Plaster of Paris cast, and external fixation with distraction respectively. The functional outcome in terms of freedom from pain, range of movement, grip power and deformity, and the radiological outcome of radial length, incongruity and radio-ulnar joint position were analysed at three months follow-up using a 3-point scoring scale. In Group A, 1 (3%) patient showed excellent result, 8 (27%) patients good results, 19 (63%) patients fair results and 2 (7%) patients poor result. In Group B, 14 (47%) patients showed excellent results, 11 (37%) patients good results, 4 (13%) patients fair results and 1 (3%) patient poor result. The outcome score of the Group B patients was significantly better compared to the Group A patients (p value < 0.05). External fixation has definite advantages over conventional Plaster of Paris cast in the treatment of unstable intra-articular fractures of distal radius.

  10. [Manipulative reduction and percutaneous Kirschner wire internal fixation for grade IV supination-external rotation ankle fractures].

    PubMed

    Li, Jia; Sun, Jin-Ke; Wang, Chen-Lin

    2017-06-25

    To investigate surgical skills and clinical effects of manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures. From May 2013 to October 2016, 35 patients with grade IV supination-external rotation ankle fractures were treated with percutaneous Kirschner wire internal fixation, involving 22 males and 13 females with an average age of 38.2 years ranged from 18 to 65 years old. The time from injury to operation ranged from 2 h to 10 d with an average of 5 d. Reduction quality was assessed by Burwell-Charnley radiological criteria. Baird-Jackson ankle scoring system was used to assess clinical effects. Thirty-three patients were followed up from 10 to 28 months with an average of 14 months. Fracture healing time ranged from 10 to 18 weeks with an average of 12 weeks. According to Burwell-Charnley radiological criteria, 30 cases were obtained anatomic reduction, 3 cases moderate. According to Baird-Jackson ankle scoring system, total score was 93.8±5.4, 17 cases got excellent result, 12 good, 2 fair and 2 poor. Manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures has advantages of reliable efficacy, less complications. But higher require techniques were required for closed reduction. It is not suitable for severe crushed fracture and compressive articular surface fracture.

  11. Surgical correction of bilateral metacarpophalangeal valgus with curved osteotomies and type II external skeletal fixation in a seven-month-old alpaca.

    PubMed

    Schoonover, Mike J; Whitfield, Chase T; Rochat, Mark C; Streeter, Robert N; Sippel, Kate

    2016-09-20

    To report the successful surgical correction of severe bilateral metacarpophalangeal valgus angular limb deformities in a seven-month-old intact male alpaca cria using curved osteotomies stabilized with type II external skeletal fixation. Using a 21 mm crescentic shaped oscillating saw blade, bilateral osteotomies were performed in the distal metaphyses of the fused third and fourth metacarpal bones to correct valgus angular limb deformity of the metacarpophalangeal joints. Axial alignment of each limb was achieved by medially rotating the distal metacarpus in the frontal plane along the curved osteotomies. The osteotomies were stabilized using type II external skeletal fixators. The alpaca was immediately weight-bearing following the surgical procedure and no to minimal lameness was observed during healing of the osteotomies. Evaluation at five and 10 months following the surgery demonstrated acceptable axial alignment in the left forelimb while moderate to severe varus deformity (overcorrection) was observed in the right. Curved osteotomy of the distal metacarpus stabilized with type II external skeletal fixation can provide a favourable outcome in older alpaca crias affected with metacarpophalangeal angular limb deformities. Placement of the distal transfixation pins relative to the metacarpal physes should be carefully evaluated as overcorrection is possible, especially if growthpotential remains in only one physis of the fused third and fourth metacarpal bones.

  12. Nonunion of the humerus following intramedullary nailing treated by Ilizarov hybrid fixation.

    PubMed

    Raschke, M; Khodadadyan, C; Maitino, P D; Hoffmann, R; Südkamp, N P

    1998-02-01

    A case of a posttraumatic humeral shaft nonunion, after intramedullary stabilization with a Seidel nail, is presented. Severe osteoporosis, an oligotrophic nonunion, subclinical infection, and adhesive capsulitis of the glenohumeral joint were present. Due to the subclinical infection and severe osteoporosis, other major invasive therapeutic options such as intramedullary nailing or compression plating and bone grafting were not applicable. Nonoperative treatment was also not indicated secondary to the pain and disability present. External fixation with the Ilizarov hybrid fixator seemed to offer a minimally invasive treatment modality without the need of additional bone grafting. After fourteen weeks of "callus massage," consisting of closed alternating compression and distraction with an Ilizarov hybrid fixator, osseous consolidation was achieved. Eight months after Ilizarov treatment the patient had returned to work as a mechanic. At the one-year follow-up examination, the patient presented pain free and with near normal shoulder and elbow motion, with stable osseous consolidation of the humerus. In some cases of nonunion of the humerus shaft, when standard treatment options are not recommended, external fixation with an Ilizarov hybrid fixator may offer a salvage procedure with a successful clinical outcome.

  13. Two-stage open reduction and internal fixation versus limited internal fixation combined with external fixation: a meta-analysis of postoperative complications in patients with severe Pilon fractures.

    PubMed

    Cui, Xueliang; Chen, Hui; Rui, Yunfeng; Niu, Yang; Li, He

    2018-01-01

    Objectives Two-stage open reduction and internal fixation (ORIF) and limited internal fixation combined with external fixation (LIFEF) are two widely used methods to treat Pilon injury. However, which method is superior to the other remains controversial. This meta-analysis was performed to quantitatively compare two-stage ORIF and LIFEF and clarify which method is better with respect to postoperative complications in the treatment of tibial Pilon fractures. Methods We conducted a meta-analysis to quantitatively compare the postoperative complications between two-stage ORIF and LIFEF. Eight studies involving 360 fractures in 359 patients were included in the meta-analysis. Results The two-stage ORIF group had a significantly lower risk of superficial infection, nonunion, and bone healing problems than the LIFEF group. However, no significant differences in deep infection, delayed union, malunion, arthritis symptoms, or chronic osteomyelitis were found between the two groups. Conclusion Two-stage ORIF was associated with a lower risk of postoperative complications with respect to superficial infection, nonunion, and bone healing problems than LIFEF for tibial Pilon fractures. Level of evidence 2.

  14. Management of Complete Talocrural Luxations by Selective Talocrural Arthrodesis using Hybrid Transarticular External Skeletal Fixation in Dogs.

    PubMed

    Yardımcı, Cenk; Önyay, Taylan; İnal, Kamil S; Özbakır, Deniz B; Özak, Ahmet

    2018-06-16

     This article presents a novel surgical technique in the management of open complete talocrural luxations and evaluates the results, and clinical benefits with its routine clinical utilization.  Retrospective study.  Seventeen medium- or large-breed client-owned dogs of different breed, age and sex with complete talocrural luxations and radiographic follow-up of at least 24 weeks duration.  Selective talocrural arthrodesis was performed by using a hybrid transarticular external skeletal fixator frame. Clinical and radiographical evaluation was performed regarding the lesion, concomitant injury, duration of the surgery, time to first use of the limb, fixator removal time, complications and clinical outcomes.  Dogs started to use the injured limb between postoperative days 1 to 11. Pin or wire tract related complications were observed in all dogs. Time to fixator removal ranged from 57 to 90 days with a median of 73 days. All of the operated joints with an exception of one dog resulted in talocrural fusion. Mid-term clinical outcomes score was regarded as excellent in 13/17 dogs, good in 3/17 dogs and poor in 1/17 dogs subject to authors' evaluation.  A transarticular hybrid external fixator may allow early use of postoperative limb with an excellent patient compliance and is well tolerated as well. The technique showed a promising opportunity of providing favourable limb use. Schattauer GmbH Stuttgart.

  15. Novel Anterior Plating Technique for Patella Fracture Fixation.

    PubMed

    Siljander, Matthew P; Vara, Alexander D; Koueiter, Denise M; Wiater, Brett P; Wiater, Patrick J

    2017-07-01

    Patella fracture fixation remains a significant challenge for orthopedic surgeons. Although tension band fixation allows for reliable osseous union, especially in simple fracture patterns, it still presents several problems. Plate fixation of patella fractures is a method that allows for more rigid stabilization and earlier mobilization. At the authors' level 1 trauma center, one fellowship-trained trauma surgeon has transitioned to using a novel anterior, low-profile mesh plate construct for all types of patella fractures. This construct allows for stable fixation, osseous union, and neutralization of the inferior pole for even the most comminuted of patella fractures. [Orthopedics. 2017; 40(4):e739-e743.]. Copyright 2017, SLACK Incorporated.

  16. Hybrid external fixation in high-energy elbow fractures: a modular system with a promising future.

    PubMed

    Lerner, A; Stahl, S; Stein, H

    2000-12-01

    Severe, high-energy, periarticular elbow injuries producing a "floating joint" are a major surgical challenge. Their reconstruction and rehabilitation are not well documented. Therefore, the following reports our experience with treating such injuries caused by war wounds. Seven adults with compound open peri- and intra-articular elbow fractures were treated in hybrid ring tubular fixation frames. After debridement, bone stabilization, and neurovascular reconstructions, early controlled daily movements were started in the affected joint. These seven patients had together seven humeral, five radial, and six ulnar fractures. All fractures united at a median time of 180 days. No deep infection developed. The functional end results assessed by the Khalfayan functional score were excellent in two, good in one, and fair in four of these severely mangled upper extremities. None was amputated. The Mangled Extremity Severity Score has been shown to be unable to provide a reliable assessment for severe high-energy limb injuries surgically managed with the modular hybrid thin wire tubular external fixation system. This hybrid system is a very useful addition to the surgical armamentarium of orthopedic trauma surgeons. It both allows complex surgical reconstructions and reduces the incidence of deep infections in these heavily contaminated injuries. The hybrid circular (thin wire) external fixation system is very modular and may provide secure skeletal stabilization even in cases of severely comminuted juxta-articular fractures on both sides of the elbow joint (floating elbow) with severe damage to soft tissues. This fixation system allows individual fixation of forearm bone fractures, thus allowing the preservation of pronation-supination movements.

  17. Nature and results of treatment of war wounds caused by cluster bombs.

    PubMed

    Mitković, Milorad; Bumbasirević, Marko; Grubor, Predrag; Milenković, Sasa; Micić, Ivan; Stojiljković, Predrag; Kostić, Igor; Karaleić, Sasa; Stamenić, Sonja; Pavlović, Predrag; Stanojlović, Milos; Jovanović, Vladimir; Radovanović, Zoran; Cirić, Tamara; Kutlesić-Stojanović, Katarina; Mitković, Milan

    2013-01-01

    The aim of this study is to describe the nature of war wounds with fracture caused by cluster bombs and to suggest treatment options for such injuries. The nature of wounds caused by cluster bombs differs from those caused by conventional arms (they are more severe). The sides of the wounds are represented by conquasated soft tissues (such as fat and muscle) with thick dead tissues, ordinarily with a thickness of 0.5-4.5 cm. Another main characteristic of such injuries is the high percentage of amputations needed due to the high rate of neurovascular damage. This paper investigates the cases of 81 patients who sustained a total of 99 war wounds with fractures. The average age of the patients was 32.7 years while the youngest was 20 and the oldest, 77. According to The International Committee of the Red Cross (ICRC) classification of war wounds, 14 patients had grade I injuries, 48 patients grade II, and 29 patients, grade III. Mitkovic external fixation system, known also as the "War Fixator" was used for all fractures fixation. One protocol, which was a modification of the ICRC's protocol adapted to our specific conditions, was used throughout the study. For solving soft tissue defects, a rotator fasciocutan flap was the most frequently used. For solving of bones defect Mitkovic reconstructive external fixation device was used. All fractures we treated healed. We concluded that shortening the procedural time and being a very simple, immediate using of Mitkovic versatile external fixator ("War Fixator") is, leads to desirable results.

  18. Fixation of silicone stents in the subglottic trachea: preventing stent migration using a fixation apparatus.

    PubMed

    Miwa, Keisuke; Takamori, Shinzo; Hayashi, Akihiro; Fukunaga, Mari; Shirouzu, Kazuo

    2004-12-01

    Silicone stents are widely used to treat benign or malignant airway stenosis. However, since straight silicone stents placed into the subglottic trachea to treat stenosis display a high risk of migration, novel approaches are required. The present report outlines our method of external fixation for silicone stents in the subglottic trachea. This technique utilizes a fixation apparatus, is readily performed, and may help to overcome the hesitation seen in placing silicone stents for subglottic tracheal stenosis.

  19. Acromioclavicular joint reconstruction by coracoid process transfer augmented with hook plate.

    PubMed

    Wang, Yeming; Zhang, Jianguo

    2014-06-01

    Various techniques have been reported for the treatment of chronic acromioclavicular (AC) joint separation. The purpose of this study was to evaluate the results of surgical construction of coracoclavicular ligament using coracoid process transfer augmented with a hook plate fixation. Twenty-one patients treated with coracoid process transfer augmented with a hook plate fixation for chronic type III and V AC injuries were retrospectively analysed in 2003-2009. The age of the patients ranged from 23 to 58 years with an average age of 41.6 years. The patients were followed up clinically and radiographically, with an average of 33.0 months. Functional status and the ability to return to work were recorded during follow-up. Constant score and visual analogue scale (VAS) for pain were measured. The mean Constant score has increased from 70.9 points preoperatively to 90.7 points at follow-up. The mean VAS score has decreased from 4.7 preoperatively to 1.2 at follow-up. The average abduction was 172°, forward flexion was 170° and external rotation was 56°. There were 10 excellent results, 10 good results and one fair result. All patients had resumed their job or returned to original sport activity at mean 3.7 months postoperatively. No reduction loss was observed after plate removal and the final follow-up. Despite retrospective nature of the study, the outcomes of surgical construction with process transfer augmented with hook plate fixation are promising for chronic type III and V AC injuries. Therapeutic level IV. Retrospective case series, treatment study. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Arthroscopically assisted elbow interposition arthroplasty without hinged external fixation: surgical technique and patient outcomes.

    PubMed

    Chauhan, Aakash; Palmer, Bradley A; Baratz, Mark E

    2015-06-01

    Total elbow arthroplasty is successful in older, lower demand patients but not in the younger, more active individual with severe elbow arthritis. Interposition arthroplasty is an alternative for younger patients who hope to minimize the degree to which arm use is restricted. Interposition arthroplasty traditionally involves release of all ligaments and capsule. As a result, the postoperative care included the use of a hinged external fixator of the elbow to apply distraction and to permit motion during the early phases of healing. We describe a novel surgical technique without a hinged external fixator that allows secure fixation of the interposition graft through arthroscopic assistance and maintains the integrity of the medial collateral ligament with only a takedown and repair of the lateral collateral ligament complex. A retrospective chart review was performed to analyze 4 patients with an average age of 57 years who underwent surgery between 2007 and 2011. The patients were also contacted to assess elbow-specific American Shoulder and Elbow Surgeons and Disabilities of the Arm, Shoulder, and Hand scores. The average follow-up was 3.6 years (range, 2.5-6 years), and 1 patient was converted to a total elbow arthroplasty after 2.5 years because of persistent pain. The remaining 3 patients have done well with regard to pain control, stability, and functional use of the operative extremity. There were no postoperative complications. On the basis of our small series of patients, an arthroscopically assisted elbow interposition arthroplasty without hinged external fixation can provide satisfactory medium-term outcomes as a salvage procedure for a difficult condition with limited options. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Management of complex femoral nonunion with monorail external fixator: A prospective study.

    PubMed

    Agrawal, Hemendra Kumar; Garg, Mohit; Singh, Balvinder; Jaiman, Ashish; Khatkar, Vipin; Khare, Shailender; Batra, Sumit; Sharma, Vinod Kumar

    2016-01-01

    To evaluate 30 patients who underwent distraction osteogenesis with monorail external fixator for complex femoral nonunion. Complex femoral nonunion includes infective non-union, gap nonunion, and limb-length discrepancy secondary to traumatic bone loss, which needs specialized treatment to ensure the functional integrity of femoral bone. 30 patients, including 28 male and 2 female (aged 22-62 years) patients, underwent surgical debridement followed by bone transport with monorail fixator. The lengthening index, radiographic consolidation index, functional status, bone healing, and various problems, obstacles, and complications encountered during the treatment were assessed. Patients underwent a mean of 2.2 (range 1-4) surgeries before presentation. The mean bone defect after surgical debridement was 5.83 cm (range 2-16 cm). The mean treatment duration was 204.7 days (range 113-543 days). The mean lengthening index was 13.06 days/cm with range from 12 to 16 days/cm. Mean maturation index was 23.51 days/cm with range from 17 to 45.5 days/cm. In our study, bone result was excellent in 17, good in 9, fair in 3, and poor in 1 patient. In our study functional outcome is excellent in 9 [30%], good in 14 [46.67%], fair in 5, and poor in 2 patients. In our study, we encountered 34 problems, 17 obstacles, and 8 complications. We concluded that monorail external fixator is an effective treatment option for complex nonunion femoral shaft fracture and its functional outcome is comparable with any other treatment options. Lack of complications and its effectiveness makes monorail external fixator the treatment of choice for complex nonunion femoral shaft.

  2. The results of bone deformity correction using a spider frame with web-based software for lower extremity long bone deformities.

    PubMed

    Tekin, Ali Çağrı; Çabuk, Haluk; Dedeoğlu, Süleyman Semih; Saygılı, Mehmet Selçuk; Adaş, Müjdat; Esenyel, Cem Zeki; Büyükkurt, Cem Dinçay; Tonbul, Murat

    2016-03-22

    To present the functional and radiological results and evaluate the effectiveness of a computer-assisted external fixator (spider frame) in patients with lower extremity shortness and deformity. The study comprised 17 patients (14 male, 3 female) who were treated for lower extremity long bone deformity and shortness between 2012 and 2015 using a spider frame. The procedure's level of difficulty was determined preoperatively using the Paley Scale. Postoperatively, the results for the patients who underwent tibial operations were evaluated using the Paley criteria modified by ASAMI, and the results for the patients who underwent femoral operations were evaluated according to the Paley scoring system. The evaluations were made by calculating the External Fixator and Distraction indexes. The mean age of the patients was 24.58 years (range, 5-51 years). The spider frame was applied to the femur in 10 patients and to the tibia in seven. The mean follow-up period was 15 months (range, 6-31 months) from the operation day, and the mean amount of lengthening was 3.0 cm (range, 1-6 cm). The mean duration of fixator application was 202.7 days (range, 104-300 days). The mean External Fixator Index was 98 days/cm (range, 42-265 days/cm). The mean Distraction Index was 10.49 days/cm (range, 10-14 days/cm). The computer-assisted external fixator system (spider frame) achieves single-stage correction in cases of both deformity and shortness. The system can be applied easily, and because of its high-tech software, it offers the possibility of postoperative treatment of the deformity.

  3. Biomechanical analysis of two fixation methods for proximal chevron osteotomy of the first metatarsal.

    PubMed

    Schuh, Reinhard; Hofstaetter, Jochen Gerhard; Benca, Emir; Willegger, Madeleine; von Skrbensky, Gobert; Zandieh, Shahin; Wanivenhaus, Axel; Holinka, Johannes; Windhager, Reinhard

    2014-05-01

    The proximal chevron osteotomy provides high correctional power. However, relatively high rates of dorsiflexion malunion of up to 17 % are reported for this procedure. This leads to insufficient weight bearing of the first ray and therefore to metatarsalgia. Recent biomechanical and clinical studies pointed out the importance of rigid fixation of proximal metatarsal osteotomies. Therefore, the aim of the present study was to compare biomechanical properties of fixation of proximal chevron osteotomies with variable locking plate and cancellous screw respectively. Ten matched pairs of human fresh frozen cadaveric first metatarsals underwent proximal chevron osteotomy with either variable locking plate or cancellous screw fixation after obtaining bone mineral density. Biomechanical testing included repetitive plantar to dorsal loading from 0 to 31 N with the 858 Mini Bionix(®) (MTS(®) Systems Corporation, Eden Prairie, MN, USA). Dorsal angulation of the distal fragment was recorded. The variable locking plate construct reveals statistically superior results in terms of bending stiffness and dorsal angulation compared to the cancellous screw construct. There was a statistically significant correlation between bone mineral density and maximum tolerated load until construct failure occurred for the screw construct (r = 0.640, p = 0.406). The results of the present study indicate that variable locking plate fixation shows superior biomechanical results to cancellous screw fixation for proximal chevron osteotomy. Additionally, screw construct failure was related to levels of low bone mineral density. Based on the results of the present study we recommend variable locking plate fixation for proximal chevron osteotomy, especially in osteoporotic bone.

  4. S1 screw bending moment with posterior spinal instrumentation across the lumbosacral junction after unilateral iliac crest harvest.

    PubMed

    Alegre, G M; Gupta, M C; Bay, B K; Smith, T S; Laubach, J E

    2001-09-15

    A biomechanical study comparing fixation across the lumbosacral junction. To determine which long posterior construct across the lumbosacral junction produces the least bending moment on the S1 screw when only one ilium is available for fixation. Recent in vitro studies have demonstrated the benefit of anterior support and fixation into the ilium when instrumenting a long posterior construct across the lumbosacral junction. Four L2-sacrum constructs were tested on six synthetic models of the lumbar spine and pelvis simulating that the right ilium had been harvested. Construct 1: L2-S1 bilateral screws. Construct 2: L2-S1 + left iliac bolt. Construct 3: L2-S1 + left iliac bolt + right S2 screw. Construct 4: L2-S1 + bilateral S2 screws. The four constructs were then retested with an anterior L5-S1 strut. A flexion-extension moment was applied across each construct, and the moment at the left and right S1 pedicle screw was measured with internal strain gauges. Iliac bolt fixation was found to significantly decrease the flexion-extension moment on the ipsilateral S1 screw by 70% and the contralateral screw by 26%. An anterior L5-S1 strut significantly decreased the S1 screw flexion-extension moment by 33%. Anterior support at L5-S1 provided no statistical decrease in the flexion-extension moment when bilateral posterior fixation beyond S1 was present with either a unilateral iliac bolt and contralateral S2 screw, or bilateral S2 screws. There is a significant decrease in the flexion-extension moment on the S1 screw when extending long posterior constructs to either the ilium or S2 sacral screw. There is no biomechanical advantage of the iliac bolt over the S2 screw in decreasing the moment on the S1 screw in flexion and extension. Adding anterior support to long posterior constructs significantly decreases the moment on the S1 screw. Adding distal posterior fixation to either the ilium or S2 decreases the moment on S1 screws more than adding anterior support. Further, adding anterior support when bilateral distal fixation past S1 is already present does not significantly decrease the moment on the S1 screws in flexion and extension.

  5. Free flap reconstructions of tibial fractures complicated after internal fixation.

    PubMed

    Nieminen, H; Kuokkanen, H; Tukiainen, E; Asko-Seljavaara, S

    1995-04-01

    The cases of 15 patients are presented where microvascular soft-tissue reconstructions became necessary after internal fixation of tibial fractures. Primarily, seven of the fractures were closed. Eleven fractures had originally been treated by open reduction and internal fixation using plates and screws, and four by intramedullary nailing. All of the patients suffered from postoperative complications leading to exposure of the bone or fixation material. The internal fixation material was removed and radical revision of dead and infected tissue was carried out in all cases. Soft tissue reconstruction was performed using a free microvascular muscle flap (11 latissimus dorsi, three rectus abdominis, and one gracilis). In eight cases the nonunion of the fracture indicated external fixation. The microvascular reconstruction was successful in all 15 patients. In one case the recurrence of deep infection finally indicated a below-knee amputation. In another case, chronic infection with fistulation recurred postoperatively. After a mean follow-up of 26 months the soft tissue coverage was good in all the remaining 13 cases. All the fractures united. Microvascular free muscle flap reconstruction of the leg is regarded as a reliable method for salvaging legs with large soft-tissue defects or defects in the distal leg. If after internal fixation of the tibial fracture the osteosynthesis material or fracture is exposed, reconstruction of the soft-tissue can successfully be performed by free flap transfer. By radical revision, external fixation, bone grafting, and a free flap the healing of the fracture can be achieved.

  6. Rapid maxillary distraction protocol utilizing the halo distraction system and rigid internal fixation.

    PubMed

    Baker, Stephen B; Reid, Russell R; Burkey, Brooke; Bartlett, Scott P

    2007-09-01

    To shorten head frame wear time associated with external halo distraction (HD), we have adapted a protocol for maxillary distraction with the halo system that integrates plate fixation. All patients had a history of cleft lip and/or palate and maxillary retrusion > or = 8 mm. Five patients treated with this protocol and followed for at least 1 year were included in this study. The protocol included a 3-day latency period, variable maxillary distraction, and removal of the halo device with simultaneous rigid internal fixation. Two patients had a variable period of maxillomandibular fixation (MMF), which maintained the maxillary advancement and idealized intercuspal position while permitting further callus maturation. Cephalographs were obtained preoperatively, immediately following distractor removal, and 1 year after rigid internal fixation. The mean age at time of surgery was 18.7 years. The maxillary deficiency ranged from 8 to 15 mm (mean = 10.6 mm). All five patients demonstrated excellent occlusion. Cephalometric analysis 1-year post rigid internal fixation revealed minimal (<1 mm) skeletal relapse. Rapid maxillary distraction followed by MMF to maintain maxillary advancement may reduce halo device wear to 1 to 2 weeks. MMF optimizes occlusion by forcing the maxillary teeth into maximal intercuspal position. Rigid fixation is not only associated with less long-term relapse compared to nonrigid forms of fixation, but also minimizes the incidence of nonunion. This treatment protocol provides the advancement possible with distraction osteogenesis and the accuracy of orthognathic surgery, thereby minimizing external head frame wear.

  7. Functional outcome of knee arthrodesis with a monorail external fixator.

    PubMed

    Roy, Alfred Cyril; Albert, Sandeep; Gouse, Mohamad; Inja, Dan Barnabas

    2016-04-01

    Several methods for obtaining knee arthrodesis have been described in the literature and world; over, the commonest cause for arthrodesis is a failed arthroplasty. Less commonly, as in this series, post-infective or traumatic causes may also require a knee fusion wherein arthroplasty may not be indicated. We present salient advantages along with the radiological and functional outcome of twenty four patients treated with a single monorail external fixator. All patients went on develop fusion at an average of 5.4 months with an average limb length discrepancy of 3 cm (1.5-6 cm). Improvements in functional outcome as assessed by the lower extremity functional score (LEFS), and the SF-36 was significant (p = 0.000). Knee arthrodesis with a single monorail external fixator is a reasonable single-staged salvage option in patients wherein arthroplasty may not be the ideal choice. The outcome, though far from ideal, is definitely positive and predictable.

  8. Humeral lengthening and proximal deformity correction with monorail external fixator in young adults.

    PubMed

    Ruan, Hongjiang; Zhu, Yi; Liu, Shen; Kang, Qinglin

    2018-05-01

    Several humeral lengthening or simultaneous deformity corrections through one osteotomy using various external fixators were reported, while literature regarding correction of shortening and proximal varus deformity is scarce. This retrospective clinical study evaluated the results of preforming an acute correction and delayed lengthening in young adults through two osteotomies using monorail external fixator. We report seven patients with various pathologies who underwent humeral proximal deformity correction and lengthening between 2009 and 2015. Pre-operative and post-operative clinical and radiographic data were collected. The mean follow-up time was 33.4 months (25-46 months). The humeral neck-shaft angle improved from 97.9° (85-110°) to 138.6° (135-145°). The magnitude of lengthening achieved was average 7.6 cm (range, 6-10 cm) at an average healing index of lengthening of 30.2 days/cm (range, 27.7-35.4 days/cm). There was a significant increase in range of shoulder abduction, and active abduction improved from pre-operative 136.4° (range, 95-160°) to post-operative 166.4° (range, 150-180°). The DASH score improved significance from 23.29 ± 8.36 to 6.57 ± 3.65 (t = 4.848; p < 0.001). Acute deformity correction and gradual lengthening with the monorail external fixator can be used for humeral shortening and proximal varus angular deformity. Functional improvement is expected after surgery and post-operative therapy.

  9. Objective guidelines for removing an external fixator after tibial lengthening using pixel value ratio: a pilot study.

    PubMed

    Zhao, Li; Fan, Qing; Venkatesh, K P; Park, Man S; Song, Hae Ryong

    2009-12-01

    During limb lengthening over an intramedullary nail, decisions regarding external fixator removal and weightbearing depend on the amount of callus seen at the lengthening area on radiographs. However, this method is subjective and objective evaluation of the amount of callus likely would minimize nail or interlocking screw breakage and refracture after fixator removal. We asked how many cortices with full corticalization of the newly formed bone at the lengthening area are needed to allow fixator removal and full weightbearing and how to radiographically determine the stage of corticalization. We retrospectively reviewed 17 patients (34 lengthenings) who underwent bilateral tibial lengthenings over an intramedullary nail. The average gain in length was 7.2 +/- 3.4 cm. We determined the pixel value ratio (ratio of pixel value of regenerate versus the mean pixel value of adjacent bone) of the lengthened area on radiographs. There were no nail or screw breakage and refracture. Partial weightbearing with crutches was permitted when the pixel value ratio was 1 in two cortices and full weightbearing without crutches was permitted when the pixel value ratio was 1 in three cortices. The pixel value ratio on radiographs can be an objective parameter for callus measurement and may provide guidelines for the timing of external fixator removal. We cannot determine from our limited data the minimum pixel value in how many cortices would suggest safe removal, but we can say our criteria were not associated with subsequent refracture.

  10. Biomechanical analysis of acromioclavicular joint dislocation treated with clavicle hook plates in different lengths.

    PubMed

    Shih, Cheng-Min; Huang, Kui-Chou; Pan, Chien-Chou; Lee, Cheng-Hung; Su, Kuo-Chih

    2015-11-01

    Clavicle hook plates are frequently used in clinical orthopaedics to treat acromioclavicular joint dislocation. However, patients often exhibit acromion osteolysis and per-implant fracture after undergoing hook plate fixation. With the intent of avoiding future complications or fixation failure after clavicle hook plate fixation, we used finite element analysis (FEA) to investigate the biomechanics of clavicle hook plates of different materials and sizes when used in treating acromioclavicular joint dislocation. Using finite element analysis, this study constructed a model comprising four parts: clavicle, acromion, clavicle hook plate and screws, and used the model to simulate implanting different types of clavicle hook plates in patients with acromioclavicular joint dislocation. Then, the biomechanics of stainless steel and titanium alloy clavicle hook plates containing either six or eight screw holes were investigated. The results indicated that using a longer clavicle hook plate decreased the stress value in the clavicle, and mitigated the force that clavicle hook plates exert on the acromion. Using a clavicle hook plate material characterized by a smaller Young's modulus caused a slight increase in the stress on the clavicle. However, the external force the material imposed on the acromion was less than the force exerted on the clavicle. The findings of this study can serve as a reference to help orthopaedic surgeons select clavicle hook plates.

  11. Characterization of interfragmentary motion associated with common osteosynthesis devices for rat fracture healing studies.

    PubMed

    Meyers, Nicholaus; Sukopp, Matthias; Jäger, Rudolf; Steiner, Malte; Matthys, Romano; Lapatki, Bernd; Ignatius, Anita; Claes, Lutz

    2017-01-01

    Rat models are widely used in preclinical studies investigating fracture healing. The interfragmentary movement at a fracture site is critical to the course of healing and therefore demands definition in order to aptly interpret the experimental results. Estimation of this movement requires knowledge of the fixation stiffness and loading. The characteristic loading for the rat femur has been estimated, but the stiffness of fixation used in rat studies has yet to be fully described. This study aimed to determine the 6 degree of freedom stiffness of four commonly used implants, two external fixators (RatExFix and UlmExFix), a locking plate, and a locking intramedullary nail, in all degrees of freedom and estimate the interfragmentary movement under specific physiological loads. The external fixator systems allow the greatest movement. Mounted 45° anterolateral on the femur, the RatExFix allows an average of 0.88 mm of motion in each anatomic direction while the stiffer UlmExFix allows about 0.6 mm of motion. The nail is far stiffer than the other implants investigated while the plate allows movement of an intermediate magnitude. Both the nail and plate demonstrate higher axial than shear stiffness. The relatively large standard deviations in external fixator shear motion imply strong dependence on bone axis alignment across the gap and the precise orientation of the specimen relative to the loading. The smaller standard deviation associated with the nail and plate results from improved alignment and minimization of the influence of rotational positioning of the specimen due to the reduced implant eccentricity relative to the specimen axis. These results show that the interfragmentary movement is complex and varies significantly between fixation devices but establishes a baseline for the evaluation of the results of different studies.

  12. Characterization of interfragmentary motion associated with common osteosynthesis devices for rat fracture healing studies

    PubMed Central

    Steiner, Malte; Matthys, Romano; Lapatki, Bernd; Ignatius, Anita; Claes, Lutz

    2017-01-01

    Rat models are widely used in preclinical studies investigating fracture healing. The interfragmentary movement at a fracture site is critical to the course of healing and therefore demands definition in order to aptly interpret the experimental results. Estimation of this movement requires knowledge of the fixation stiffness and loading. The characteristic loading for the rat femur has been estimated, but the stiffness of fixation used in rat studies has yet to be fully described. This study aimed to determine the 6 degree of freedom stiffness of four commonly used implants, two external fixators (RatExFix and UlmExFix), a locking plate, and a locking intramedullary nail, in all degrees of freedom and estimate the interfragmentary movement under specific physiological loads. The external fixator systems allow the greatest movement. Mounted 45° anterolateral on the femur, the RatExFix allows an average of 0.88 mm of motion in each anatomic direction while the stiffer UlmExFix allows about 0.6 mm of motion. The nail is far stiffer than the other implants investigated while the plate allows movement of an intermediate magnitude. Both the nail and plate demonstrate higher axial than shear stiffness. The relatively large standard deviations in external fixator shear motion imply strong dependence on bone axis alignment across the gap and the precise orientation of the specimen relative to the loading. The smaller standard deviation associated with the nail and plate results from improved alignment and minimization of the influence of rotational positioning of the specimen due to the reduced implant eccentricity relative to the specimen axis. These results show that the interfragmentary movement is complex and varies significantly between fixation devices but establishes a baseline for the evaluation of the results of different studies. PMID:28453556

  13. Evaluation of a nontoxic rigid polymer as connecting bar in external skeletal fixators.

    PubMed

    Störk, Christoph K; Canivet, Philippe; Baidak, Alexandre A; Balligand, Marc H

    2003-01-01

    To investigate the mechanical characteristics of a nontoxic, low-cost, rigid polymer (RP) and to compare the structural and mechanical properties of a full-frame external skeletal fixator (ESF) with either RP connecting bars, polymethylmethacrylate (PMMA) connecting bars, or stainless-steel (SS) clamps and connecting bars. In vitro mechanical evaluation. Mechanical properties were assessed using an in vitro bone fracture model with a bilateral uniplanar ESF (type II). Identical ESF were built with connecting bars using RP (n = 8), PMMA (n = 8), and SS connecting bars and clamps (System Meynard; n = 3). Nondestructive mechanical tests were performed in uniaxial compression (AC) and craniocaudal (CC) 4-point bending, as well as fatigue AC. Composite stiffness for each specimen and for each loading mode was calculated from 6 replicate measures using the slope of the load displacement curve at small displacements. RP, PMMA, and SS ESF constructs yielded mean +/- SD composite stiffness values of 227 +/- 15, 381 +/- 30, and 394 +/- 9 N/mm in AC and of 35 +/- 2, 24 +/- 2, and 15 +/- 0 N/mm in CC, respectively. Structural and mechanical properties of RP are satisfactorily rigid and fatigue resistant for its use as a connecting bar in ESF. RP connecting bars in an ESF are a reliable, versatile, nontoxic and inexpensive option for the veterinary surgeon. Copyright 2003 by The American College of Veterinary Surgeons

  14. RELATIONSHIP BETWEEN RIGIDITY OF EXTERNAL FIXATOR AND NUMBER OF PINS: COMPUTER ANALYSIS USING FINITE ELEMENTS

    PubMed Central

    Sternick, Marcelo Back; Dallacosta, Darlan; Bento, Daniela Águida; do Reis, Marcelo Lemos

    2015-01-01

    Objective: To analyze the rigidity of a platform-type external fixator assembly, according to different numbers of pins on each clamp. Methods: Computer simulation on a large-sized Cromus dynamic external fixator (Baumer SA) was performed using a finite element method, in accordance with the standard ASTM F1541. The models were generated with approximately 450,000 quadratic tetrahedral elements. Assemblies with two, three and four Schanz pins of 5.5 mm in diameter in each clamp were compared. Every model was subjected to a maximum force of 200 N, divided into 10 sub-steps. For the components, the behavior of the material was assumed to be linear, elastic, isotropic and homogeneous. For each model, the rigidity of the assembly and the Von Mises stress distribution were evaluated. Results: The rigidity of the system was 307.6 N/mm for two pins, 369.0 N/mm for three and 437.9 N/mm for four. Conclusion: The results showed that four Schanz pins in each clamp promoted rigidity that was 19% greater than in the configuration with three pins and 42% greater than with two pins. Higher tension occurred in configurations with fewer pins. In the models analyzed, the maximum tension occurred on the surface of the pin, close to the fixation area. PMID:27047879

  15. Knee arthrodesis with the Sheffield external ring fixator: fusion in 6 of 10 consecutive patients.

    PubMed

    Ulstrup, Anton K; Folkmar, Klaus; Broeng, Leif

    2007-06-01

    Knee arthrodesis with external fixation (XF) is a possible salvage procedure for infected total knee arthroplasties (TKA). We report the outcome in 10 patients who underwent arthrodesis with the Sheffield Ring Fixator. The patients had primary arthrosis in 8 cases; 2 cases were due to rheumatoid arthritis and sclerodermia. The mean time between the primary TKA and arthrodesis was 6 (0.5-14) years. The average age at arthrodesis was 69 years. The average follow-up period was 10 months. Stable fusion was obtained in 6 patients after a mean XF time of 3.6 (2-4) months. 1 patient was referred to another hospital because of nonunion. This patient showed fusion with intramedullary nailing after 7 months. 3 nonunion patients required permanent bracing. 7 patients had pin tract infections. Infections healed in all patients. The Sheffield Ring Fixator gives an acceptable fusion rate for arthrodesis in the infected TKA, with limited complications.

  16. Biomechanical stability of intramedullary technique for fixation of joint depressed calcaneus fracture.

    PubMed

    Nelson, Joshua D; McIff, Terence E; Moodie, Patrick G; Iverson, Jamey L; Horton, Greg A

    2010-03-01

    Internal fixation of the os calcis is often complicated by prolonged soft tissue management and posterior facet disruption. An ideal calcaneal construct would include minimal hardware prominence, sturdy posterior facet fixation and nominal soft tissue disruption. The purpose of this study was to develop such a construct and provide a biomechanical analysis comparing our technique to a standard internal fixation technique. Twenty fresh-frozen cadaver calcanei were used to create a reproducible Sanders type-IIB calcaneal fracture pattern. One calcaneus of each pair was randomly selected to be fixed using our compressive headless screw technique. The contralateral matched calcaneus was fixed with a nonlocking calcaneal plate in a traditional fashion. Each calcaneus was cyclically loaded at a frequency of 1 Hz for 4000 cycles using an increasing force from 250 N to 1000 N. An Optotrak motion capturing system was used to detect relative motion of the three fracture fragments at eight different points along the fracture lines. Horizontal separation and vertical displacement at the fracture lines was recorded, as well as relative rotation at the primary fracture line. When the data were averaged, there was more horizontal displacement at the primary fracture line of the plate and screw construct compared to the headless screw construct. The headless screw construct also had less vertical displacement at the primary fracture line at every load. On average those fractures fixed with the headless screw technique had less rotation than those fixed with the side plate technique. A new headless screw technique for calcaneus fracture fixation was shown to provide stability as good as, or better than, a standard side plating technique under the axial loading conditions of our model. Although further testing is needed, the stability of the proposed technique is similar to that typically provided by intramedullary fixation. This fixation technique provides a biomechanically stable construct with the potential for a minimally invasive approach and improved post-operative soft tissue healing.

  17. Long-term results of various therapy concepts in severe pilon fractures.

    PubMed

    Koulouvaris, Panagiotis; Stafylas, Kosmas; Mitsionis, Gregory; Vekris, Marios; Mavrodontidis, Alexandros; Xenakis, Theodore

    2007-07-01

    Intra-articular fractures of the tibia plafond are among the most challenging of orthopaedic problems. This is a retrospective case-control study of surgically treated pilon fractures which was undertaken to compare the internal fixation with the two external fixation methods. This is a case-control study of 55 patients with 55 pilon fractures. There were 36 type C and 19 type B. Of these fractures, 24 were open and 31 closed. Three surgical protocols were used. In 20 patients, Group A, a half pin external fixator with ankle spanning was performed. The mean age of patients was 42.0 years (22.0-74.0), SD 14.1 and the mean follow-up was 77.7 months (38.0-132.0), SD 25.4. In 22 patients, Group B, a single ankle sparring ring hybrid external fixator under a small arthrotomy was performed. The mean age of patients was 48.4 years (28.0-76.0), SD 12.4 and mean follow-up was 67.9 months (36.0-132.0), SD 27.8. In 13 patients, Group C, a two-staged internal fixation was performed. The mean age was 45.6 years (30.0-66.0), SD 9.7 and the mean follow-up was 78.6 months (55.0-132.0), SD 25.4. We addressed the dissimilarity of the type of fracture in each group performing supplementary stratified analyses within each fracture type group. Group A had union in 6.9 months, group B in 5.6 months and group C in 5.1 months; P = 0.009. Six patients (Group A), two (Group B), and one (Group C) had limitation of ankle motion; P = 0.47. One patient from group C developed infection and the plate was removed. Four patients (Group A), one (Group B), and one (Group C) have developed posttraumatic arthritis (loss of joint space and pain); P = 0.25. Seven patients from Group A have reduced their activities; P = 0.004. In stratified statistical analysis by type of fracture, the associations noted for both fracture groups combined were also noted separately within each fracture group. In this long term follow-up study, the two-staged internal fixation and the hybrid fixation with small arthrotomy were equally efficacious in achieving bone union. Patients in external fixation with the ankle spanning had a significantly higher rate of delayed union. Also more patients in this group have reduced their activities.

  18. Outcome of limb fracture repair in rabbits: 139 cases (2007-2015).

    PubMed

    Sasai, Hiroshi; Fujita, Daisuke; Seto, Eiko; Denda, Yuki; Imai, Yutaro; Okamoto, Kanako; Okamura, Kensaku; Furuya, Masaru; Tani, Hiroyuki; Sasai, Kazumi

    2018-02-15

    OBJECTIVE To evaluate outcome of limb fracture repair in rabbits. DESIGN Retrospective case series. ANIMALS 139 client-owned rabbits with limb fractures treated between 2007 and 2015. PROCEDURES Medical records were reviewed for information on fracture location, fracture treatment, and time to fracture healing. RESULTS 25 rabbits had fractures involving the distal aspects of the limbs (ie, metacarpal or metatarsal bones, phalanges, and calcaneus or talus). Fractures were treated in 23 of these 25 rabbits (external coaptation, n = 17; external skeletal fixation, 4; and intramedullary pinning, 2) and healed in all 23, with a median healing time of 28 days (range, 20 to 45 days). One hundred ten rabbits had long bone fractures, and fractures were treated in 100 of the 110 (external skeletal fixation, n = 89; bone plating, 1; intramedullary pinning, 3; and external coaptation, 7). The percentage of fractures that healed was significantly lower for open (14/18) than for closed (26/26) tibial fractures and was significantly lower for femoral (19/26) and treated humeral (4/6) fractures than for radial (23/24) or closed tibial (26/26) fractures. Micro-CT was used to assess fracture realignment during external skeletal fixator application and to evaluate fracture healing. CONCLUSIONS AND CLINICAL RELEVANCE The prognosis for rabbits with limb fractures was good, with fractures healing in most rabbits following fracture repair (109/123). Micro-CT was useful in assessing fracture realignment and evaluating fracture healing.

  19. Reverse shoulder arthroplasty glenoid fixation: is there a benefit in using four instead of two screws?

    PubMed

    James, Jaison; Allison, Mari A; Werner, Frederick W; McBride, Devin E; Basu, Niladri N; Sutton, Levi G; Nanavati, Vipul N

    2013-08-01

    To allow osseous integration to occur and thus provide long-term stability, initial glenoid baseplate fixation must be sufficiently rigid. A major contributing factor to initial rigid fixation is baseplate screw fixation. Current baseplate designs use a 4-screw fixation construct. However, recent literature suggests adequate fixation can be achieved with fewer than 4 screws. The purpose of the present study was to determine whether a 4-screw construct provides more baseplate stability than a 2-screw construct. A flat-backed glenoid baseplate with 4 screw hole options was implanted into 6 matched pairs of cadaver scapulas using standard surgical technique. Within each pair, 2 screws or 4 screws were implanted in a randomized fashion. A glenosphere was attached allowing cyclic loading in an inferior-to-superior direction and in an anterior-to-posterior direction. Baseplate motion was measured using 4 linear voltage displacement transducers evenly spaced around the glenosphere. There was no statistical difference in the average peak central displacements between fixation with 2 or 4 screws (P = .338). Statistical increases in average peak central displacement with increasing load (P < .001) and with repetitive loading (P < .002) were found. This study demonstrates no statistical difference in baseplate motion between 2-screw and 4-screw constructs. Therefore, using fewer screws could potentially lead to a reduction in operative time, cost, and risk, with no significant negative effect on overall implant baseplate motion. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  20. Distal femoral derotational osteotomy with external fixation for correction of excessive femoral anteversion in patients with cerebral palsy.

    PubMed

    Skiak, Eyad; Karakasli, Ahmet; Basci, Onur; Satoglu, Ismail S; Ertem, Fatih; Havitcioglu, Hasan

    2015-09-01

    Patients with cerebral palsy (CP) disorder often develop rotational hip deformity. Increasing deformities impair already diminished walking abilities; femoral osteotomies are often performed to maintain and improve walking abilities. Fixation of osteotomies with condylar plates has been used successfully, but does not often enable immediate postoperative full weight-bearing. To avoid considerable postoperative rehabilitation deficit and additional bone loss because of inactivity, a postoperative treatment with full weight-bearing, is therefore, desirable. Self-tapping Schanz screws with a unilateral external fixator crossing the knee joint providing stronger anchoring in osteopenic bone might fulfill these demands. A retrospective study was carried out on 27 ambulatory CP patients, mean age 17.5 years (range 9-22 years); 11 patients with bilateral severe intoeing deformities underwent a supracondylar femoral osteotomy between September 2008 and April 2012. All patients were allowed to bear their full weight postoperatively. The aim of this study was to describe the technique, the results of this technique, to evaluate the time required for bone healing, and the type of complications associated with a distal derotational femoral osteotomy fixed with a uniaxial external fixator crossing the knee joint. A total of 27 patients were studied [mean weight 48.8 kg (range 29.8-75 kg)]. The mean preoperative rotation included internal rotation of 69° and external rotation of 17°. All patients were evaluated clinically and radiographically for a minimum of 1 year after surgery. There was a significant decrease in the mean medial rotation from 69° to 32° (P=0.00034). The lateral rotation increased significantly from preoperative 17° to postoperative 45° (P=0.0011). The femoral anteversion decreased significantly from a mean of 55° preoperatively to a mean 17° postoperatively (P=0.030). All patients, except one, achieved solid fusion uneventfully. One patient was a 16-year-old female who had sustained a knee flexion contracture of 30° because of a delay in the physiotherapy program. One 13-year-old female patient with a bilateral osteotomy had a nondisplaced fracture in her right femur after a direct trauma 2 weeks after removal of an external fixator, and was treated by a cast. Another 17-year-old male patient developed a nonunion because of loosening of two pins and achieved solid union after revision by dynamic compression plate plating. Besides four cases with superficial pin-tract infection, no other complications were documented. Minimally invasive supracondylar femoral derotational osteotomy fixed with a unilateral external fixators crossing the knee joint is a reliable procedure in CP patients. Most patients can be treated with early postoperative full weight-bearing. However, removal of the knee joint crossing fixator should be performed as early as possible to achieve a full range of motion.

  1. [Case-control study on T-shaped locking internal fixation and external fixation for the treatment of dorsal Barton's fracture].

    PubMed

    Chen, Huan-qing; Wen, Xi-le; Li, Yang-ming; Wen, Cong-you

    2015-06-01

    To compare clinical effect of T-shaped locking internal fixation and external fixation in treating dorsal Barton's fracture,and investigate selective strategy of internal fixation. From January 2008 to January 2013, 100 patients with dorsal Barton's fracture were randomly divided into two groups. In treatment group, there were 30 males and 20 females with an average age of (33.8±3.6) years old;30 cases were type B, 20 cases were type C;and treated with T-shaped locking internal fixation. In control group, there were 32 male and 18 females with an average age of (32.9±3.4) years old; 29 cases were type B, 21 cases were type C; and treated with external fixation. Volar tilt, ulnar deviation and radial height at 3 months after operation were detected and compared between two groups. Mechara functional evaluation were used to evaluate postoperative clinical effects. Clinical cure time, postoperative complications,joint mobility and function score were recorded and compared between two groups. In treatment group,volar tilt was (11.9±2.7)°, ulnar deviation was (20.8+ 2.9)°,and radial height was (10.9±1.8) mm; while volar tilt was (9.1±1.6)°, ulnar deviation was (17.1±2.9)°, and radial height was (8.1±1.5) mm in control group. Treatment group was better than control group in volar tilt, ulnar deviation and radial height. Clinical cure time in treatment group was(12.0±2.3) weeks, shorter than control group (18.0±4.1) weeks. The incidence of complications in treatment group was lower than control group. According to Mehara functional evaluation,20 cases got excellent results, 25 good, 3 moderate and 2 poor in treatment group; 16 cases got excellent results, 14 good, 10 moderate and 10 poor in control group. Treatment group was better than control group in clinical effects. T-shaped locking internal fixation with postoperative functional exercise for the treatment of dorsal Barton's fracture fits for biomechanics demands,and has advantages of stable fixation,rapid recovery, less complications and good functional recovery, it has better clinical effects.

  2. Rostral mandibular fracture repair in a pet bearded dragon (Pogona vitticeps).

    PubMed

    Nau, Melissa R; Eshar, David

    2018-04-15

    CASE DESCRIPTION A 2-year-old male bearded dragon (Pogona vitticeps) was evaluated because of a traumatic mandibular fracture. CLINICAL FINDINGS An open comminuted fracture of the rostral aspect of the right mandible was evident, with a fragment of bone exposed and dorsally displaced. Whole-body radiography revealed no evidence of additional injury. Other findings were unremarkable, except for moderate anemia (PCV, 19%). TREATMENT AND OUTCOME The fracture fragments were stabilized with 2 crossed 36-gauge interfragmentary wire loops. An external fixator device was fashioned from four 25-gauge needles inserted at alternating angles through the fracture fragments; plastic IV fluid line tubing filled with dental acrylic was used as a connecting bar. One day after surgery, the lizard had regained its typical activity level and appetite. Body weight was measured and the external fixator was inspected 1 week after surgery and monthly thereafter. Three months after initial injury, the fracture was stable, radiography revealed bony callus formation at the fracture site, and the external fixator was removed. Recheck radiography performed 5.5 months after initial injury revealed complete osseous union of the fracture fragments, and the interfragmentary wires were removed. CLINICAL RELEVANCE Surgical management of the traumatic comminuted mandibular fracture in this bearded dragon by means of a combination of internal and external fixation resulted in complete healing of the mandible and restoration of function. Management of this complicated fracture was achieved with the aid of readily available and inexpensive supplies in a clinical setting, which may be useful to other clinicians in the management of similar cases.

  3. Subtalar distraction osteogenesis for posttraumatic arthritis following intra-articular calcaneal fractures.

    PubMed

    Fan, Wei-Li; Sun, Hong-Zhen; Wu, Si-Yu; Wang, Ai-Min

    2013-03-01

    The most common treatment for old calcaneal fractures accompanied by subtalar joint injury is the use of subtalar in situ arthrodesis and subtalar distraction bone-block arthrodesis or osteotomy. This article describes the introduction of a novel surgical treatment, gradual subtalar distraction with external fixation and restoration of the calcaneal height, and presents an assessment of its efficacy. The protruding lateral calcaneus and the articular surfaces and subchondral bone of the posterior facet of the subtalar joint were surgically removed. An external fixator, attached with 2 pins in the subcutaneous tibia and 2 pins in the posterolateral calcaneus, was used to fix the subtalar joint for 7 to 10 days followed by gradual subtalar distraction at 1 mm/d. The lengthening procedure was stopped when the calcaneal height was restored according to radiography. The external fixator was removed after bone fusion. Seven cases of old calcaneal fractures accompanied by severe subtalar joint injury (8 feet) were treated using this method. Average follow-up was 14.3 months (range, 7-36 months). In all 7 cases (1 case of both feet), the postoperative wound healed primarily. The calcaneal heights of all 8 feet were partially restored. Subtalar joint bone fusion was completed within 4 to 6 months after the operation. The average preoperative American Orthopedic Foot & Ankle Society (AOFAS) hindfoot score was 25.3, and the average postoperative AOFAS score was 76.3. Subtalar distraction osteogenesis with external fixation was a novel and effective method for the treatment of old calcaneal fractures accompanied by severe subtalar joint injury in this small group of patients. Level IV, retrospective case series.

  4. An ex vivo mechanical evaluation of single versus double semitubular plate fixation of a transverse distal-third scapular osteotomy in the dog.

    PubMed

    Mair, Jacqueline J; Belkoff, Stephen M; Boudrieau, Randy J

    2003-01-01

    To compare single versus double semitubular plate fixation for scapular body fractures. Ex vivo mechanical study. Eighteen paired cadaveric canine scapulae. Transverse scapular body osteotomies were created in the distal third of 18 pairs of scapulae. One scapula of each pair was repaired with a single plate, whereas the contralateral scapula was repaired with 2 plates. Initial strength and stiffness of the constructs were measured in 10 pairs of scapulae. Eight pairs of scapulae underwent cyclic loading and then were subjected to failure testing. Double-plate fixation was significantly stronger (3,899 +/- 632 N) but not stiffer (614 +/- 130 N/mm) than the single-plate fixation (3,238 +/- 935 N and 537 +/- 202 N/mm, respectively). Cyclic loading variables were not significantly different between the 2 methods of fixation. After cyclic loading, double-plate fixation was significantly stronger (2,916 +/- 618 N) than single-plate fixation (2,347 +/- 495 N). There was no significant difference (P =.11) in stiffness between double- versus single-plate fixations: 734 +/- 247 N/mm and 595 +/- 139 N/mm, respectively. Double-plate fixation was generally stronger and stiffer than single-plate fixation. Because all constructs failed at loads that greatly exceeded those estimated to occur clinically, any difference between the 2 methods of fixation probably is not clinically relevant. Single-plate fixation may be of sufficient strength for fixation of scapular body fractures. Copyright 2003 by The American College of Veterinary Surgeons

  5. Graft-supplemented, augmented external fixation in the treatment of intra-articular distal radial fractures.

    PubMed

    Tyllianakis, Minos E; Panagopoulos, Andreas; Giannikas, Dimitrios; Megas, Panagiotis; Lambiris, Elias

    2006-02-01

    This article compares the functional and radiographic outcomes of intraarticular distal radial fractures treated with augmented external fixation in which autologous cancellous bone grafting or Norian SRS (Norian Corp, Cupertino, Calif) was used for filling the metaphyseal void. Thirty non-randomized patients, 15 in each group, with AO type C distal radius fractures (20 men and 10 women; average age: 48 years) were operatively treated between 1998-2000 and retrospectively evaluated. Radial inclination, radial length, volar tilt, and Modified Mayo Wrist Score were assessed at the most recent follow-up evaluation (average: 33.3 months). Overall, 12 (80%) patients in the Norian group had an excellent or good result, 2 had fair, and 1 had poor. In the autologous iliac bone graft group, the results were excellent or good in 11 (73.3%) patients, fair in 1, and poor in 2. No statistical difference between the two types of grafting was noted. Norian SRS is equally effective to cancellous bone as supplementary graft in comminuted distal radial fractures treated by external and Kirschner-wire fixation.

  6. Hybrid External Fixation for Arbeitsgemeinschaft für Osteosynthesefragen (AO) 43-C Tibial Plafond Fractures.

    PubMed

    Abd-Almageed, Emad; Marwan, Yousef; Esmaeel, Ali; Mallur, Amarnath; El-Alfy, Barakat

    2015-01-01

    Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 43-C tibial plafond/pilon fractures represent a challenge for the treating orthopedic surgeon. We assessed the outcomes of using hybrid external fixation for this fracture type. The present prospective cohort study was started in August 2009 and ended by July 2012. Thirty consecutive patients (mean age 37.4 ± 10.7 years) with a type C tibial plafond fracture who had presented to our tertiary care orthopedic hospital were included. Motor vehicle accidents and fall from height were the cause of the fracture in 14 (46.7%) and 13 (43.3%) patients, respectively. A type C3 fracture was present in 25 patients (83.3%), and type C1 and C2 fractures were present in 2 (6.7%) and 3 (10.0%) patients, respectively. Nine fractures (30.0%) were open. Hybrid external fixation was used for all fractures. All fractures were united; clinical healing was achieved by a mean of 18.1 ± 2.2 weeks postoperatively and radiologic healing at a mean of 18.9 ± 1.9 weeks. The fixator was removed at a mean of 20.4 ± 2.0 weeks postoperatively. At a mean follow-up point of 13.4 ± 2.6 months, the mean modified Mazur ankle score was 84.6 ± 10.4. It was not associated with wound classification (p = .256). The most commonly seen complication was ankle osteoarthritis (17 patients; 56.7%); however, it was mild in >50.0% of the affected patients. In conclusion, using hybrid external fixation for type C tibial plafond fractures resulted in good outcomes. However, this should be investigated further in studies with a higher level of evidence. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Conversion of external fixation to open reduction and internal fixation for complex distal radius fractures.

    PubMed

    Natoli, R M; Baer, M R; Bednar, M S

    2016-05-01

    Distal radius fractures are common injuries treated in a multitude of ways. One treatment paradigm not extensively studied is initial treatment by external fixation (EF) followed by conversion to open reduction internal fixation (ORIF). Such a paradigm may be beneficial in damage control situations, when there is extensive soft tissue injury, or when appropriate personnel/hospital resources are not available for immediate internal fixation. There is no increased risk of infection when converting EF to ORIF in the treatment of complex distal radius fractures when conversion occurs early or if EF pin sites are overlapped by the definitive fixation. Using an IRB approved protocol, medical records over nine years were queried to identify patients with distal radius fractures that had undergone initial EF and were later converted to ORIF. Charts were reviewed for demographic data, injury characteristics, operative details, time to conversion from EF to ORIF, assessment of whether the EF pin sites overlapped the definitive fixation, presence of infection after ORIF, complications, and occupational therapy measurements of range of motion and strength. In total, 16 patients were identified, only one of which developed an infection following conversion to ORIF. Fisher's exact testing showed that infection did not depend on open fracture, time to conversion of one week or less, presence of EF pin sites overlapping definitive fixation, fracture classification, high energy mechanism of injury, or concomitant injury to the DRUJ. Planned staged conversion from EF to ORIF for complex distal radius fractures does not appear to result in an increased rate of infection if conversion occurs early or if the EF pin sites are overlapped by definitive fixation. This treatment paradigm may be reasonable for treating complex distal radius fractures in damage control situations, when there is extensive soft tissue injury, or when appropriate personnel/hospital resources are not available for immediate internal fixation. IV, retrospective case series. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  8. Examination of Skill Acquisition and Grader Bias in a Distal Radius Fracture Fixation Model.

    PubMed

    Putnam, Matthew D; Adams, Julie E; Lender, Paul; Van Heest, Ann E; Shanedling, Janet R; Nuckley, David J; Bechtold, Joan E

    2018-03-01

    Primary: Assess the ability of faculty graders to predict the objectively measured strength of distal radius fracture fixation. Secondary: Compare resident skill variation and retention related to other knowable training data. Residents were allowed 60 minutes to stabilize a standardized distal radius fracture using an assigned fixed-angle volar plate. Faculty observed and subjectively graded the residents without providing real-time feedback. Objective biomechanical evaluation (construct strength and stiffness) was compared to subjective grades. Resident-specific characteristics (sex, PGY, and ACGME case log) were also used to compare the objective data. A simulated operating room in our laboratory. Post-graduate year 2, 3, 4, and 5 orthopedic residents. Primary: Faculty were not successful at predicting objectively measured fixation, and their subjective scoring suggests confirmation bias as PGY increased. Secondary: Resident year-in-training alone did not predict objective measures (p = 0.53), but was predictive of subjective scores (p < 0.001). Skills learned were not always retained, as 29% of residents objectively failed subsequent to passing. Notably, resident-reported case-specific experience alone was inversely correlated with objective fixation strength. This testing model enabled the collection of objective and subjective resident skill scores. Faculty graders did not routinely predict objective measures, and their subjective assessment appears biased related to PGY. Also, in vivo case volume alone does not predict objective results. Familiar faculty teaching consistency, and resident grading by external faculty unfamiliar with tested residents, might alter these results. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  9. Negative pressure wound therapy and external fixation device: a simple way to seal the dressing.

    PubMed

    Bulla, Antonio; Farace, Francesco; Uzel, André-Pierre; Casoli, Vincent

    2014-07-01

    Negative pressure therapy is widely applied to treat lower limb trauma. However, sealing a negative pressure dressing in the presence of an external fixation device may be difficult and time consuming. Therefore, screws, pins, wires, etc, may preclude the vacuum, preventing the plastic drape to perfectly adhere to the foam. To maintain the vacuum, we tried to prevent air leaking around the screws putting bone wax at the junction between the pins and the plastic drape. This solution, in our hands, avoids air leakage and helps maintain vacuum in a fast and inexpensive way.

  10. [Fat embolism syndrome following lower limb fracture despite rapid external fixation. Two case reports and review of the literature].

    PubMed

    Kleinert, K; Marug, D; Soklic, P; Simmen, H-P

    2009-09-01

    Fat embolism syndrome (FES) is a rare complication occurring in 0.9-2.2% of patients following long bone fractures. Patients present with a classical triad of respiratory manifestations, cerebral effects and petechiae. The incidence of FES is reduced by early immobilization of fractures and by minimally invasive operative management. Nevertheless, two healthy young men suffered from FES after immediate (within 3 h after trauma) external fixation of lower leg fractures. This postoperative complication should always be considered even after conservative or minimally invasive therapy.

  11. Gradual digital lengthening with autologous bone graft and external fixation for correction of flail toe in a patient with Raynaud's disease.

    PubMed

    Lamm, Bradley M; Ades, Joe K

    2009-01-01

    Iatrogenic flail toe is a complication of hammertoe surgery that occurs when an overaggressive resection of the proximal phalanx occurs. This can cause both functional and cosmetic concerns for the patient. We present a case report of the correction of a flail second toe in a patient with Raynaud's disease. The correction was achieved by means of gradual soft tissue lengthening with external fixation and an interposition autologous bone graft digital arthrodesis. After 5 months, this 2-stage procedure lengthened, stabilized, and restored the function of the toe. 4.

  12. All Internal Segmental Bone Transport and Optional Lengthening With a Newly Developed Universal Cylinder-Kombi-Tube Module for Motorized Nails-Description of a Surgical Technique.

    PubMed

    Krettek, Christian; El Naga, Ashraf

    2017-10-01

    Segmental transport is an effective method of treatment for segmental defects, but the need for external fixation during the transport phase is a disadvantage. To avoid external fixation, we have developed a Cylinder-Kombi-Tube Segmental Transport (CKTST) module for combination with a commercially available motorized lengthening nail. This CKTST module allows for an all-internal segmental bone transport and also allows for optional lengthening if needed. The concept and surgical technique of CKTST are described and illustrated with a clinical case.

  13. Correction of axial deformity during lengthening in fibular hypoplasia: Hexapodal versus monorail external fixation.

    PubMed

    Chalopin, A; Geffroy, L; Pesenti, S; Hamel, A; Launay, F

    2017-09-01

    Childhood fibular hypoplasia is a rare pathology which may or may not involve limb-length discrepancy and axial deformity in one or more dimensions. The objective of the present study was to compare the quality of the axial correction achieved in lengthening procedures by hexapodal versus monorail external fixators. The hypothesis was that the hexapodal fixator provides more precise correction. A retrospective multicenter study included 52 children with fibular hypoplasia. Seventy-two tibias were analyzed, in 2 groups: 52 using a hexapodal fixator, and 20 using a monorail fixator. Mean age was 10.2 years. Mean lengthening was 5.7cm. Deformities were analyzed and measured in 3 dimensions and classified in 4 preoperative types and 4 post-lengthening types according to residual deformity. Complete correction was achieved in 26 tibias in the hexapodal group (50%) and 2 tibias in the monorail group (10%). Mean post-correction mechanical axis deviation was smaller in the hexapodal group: 12.83mm, versus 14.29mm in the monorail group. Mean post-correction mechanical lateral distal femoral angle was 87.5° in the hexapodal group, versus 84.3° in the monorail group (P=0.002), and mean mechanical medial proximal tibial angle 86.9° versus 89.5°, respectively (P=0.015). No previous studies focused on this congenital pathology in lengthening and axial correction programs for childhood lower-limb deformity. The present study found the hexapodal fixator to be more effective in conserving or restoring mechanical axes during progressive bone lengthening for fibular hypoplasia. The hexapodal fixator met the requirements of limb-length equalization in childhood congenital lower-limb hypoplasia, providing better axial correction than the monorail fixator. IV. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Biomechanical effect of interspinous process distraction height after lumbar fixation surgery: An in vitro model.

    PubMed

    Fu, Lin; Ma, Jianxiong; Lu, Bin; Jia, Haobo; Zhao, Jie; Kuang, Mingjie; Feng, Rui; Xu, Liyan; Bai, Haohao; Sun, Lei; Wang, Ying; Ma, Xinlong

    2017-07-01

    Pedicle screw fixation may induce abnormal activity at adjacent segment and accelerate the degeneration of lumbar vertebrae. Dynamic stabilizers could provide an intermediate solution between conservative treatment and fusion surgery. Lumbar vertebral segment cephalad to instrumented fixation was the most common localization of adjacent segment degeneration. The aim of this study is to explore the use of interspinous process devices in the lumbar vertebral segment cephalad to fixation segment in changing the mechanical distribution and limiting abnormal activity of the spine. Eight specimens were tested in the following groups: intact group, instability group (bilateral facetectomy at L3-L4), fixation group (bilateral facetectomy and pedicle screw fixation at L3-L4), and hybrid fixation group (fixation at L3-L4 and simulating interspinous device implantation of 6, 8, 10, 12, 14, 16, and 18 mm at L2-L3). Range of motion, motion of vertebral body, and strain distribution change were recorded. The range of motion in extension with 16- and 18-mm hybrid constructs was significantly lower than intact, instability, and fixation groups. In flexion and lateral bending, the strain values of L4 inferior articular process with 18-mm hybrid construct have a significant difference compared with other groups. In axial rotation, under the condition of a contralateral state, the strain values of L2 superior articular process with 18-mm hybrid construct have a significant difference compared with intact and fixation groups. The strain value of the L4 inferior articular process had negative correlation with height distraction in three dimensions, except extension. A negative correlation between the strain value of the L2 superior articular process and distraction height was found in contralateral bending and contralateral axial rotation. Interspinous process devices above the fixation segment can change the mechanical distribution of the spine and limit activity in some of the segments of the spine, which may delay the degeneration of the adjacent segment.

  15. Management of civilian ballistic fractures.

    PubMed

    Seng, V S; Masquelet, A C

    2013-12-01

    The management of ballistic fractures, which are open fractures, has often been studied in wartime and has benefited from the principles of military surgery with debridement and lavage, and the use of external fixation for bone stabilization. In civilian practice, bone stabilization of these fractures is different and is not performed by external fixation. Fifteen civilian ballistic fractures, Gustilo II or IIIa, two associated with nerve damage and none with vascular damage, were reviewed. After debridement and lavage, ten internal fixations and five conservative treatments were used. No superficial or deep surgical site infection was noted. Fourteen of the 15 fractures (93%) healed without reoperation. Eleven of the 15 patients (73%) regained normal function. Ballistic fractures have a bad reputation due to their many complications, including infections. In civilian practice, the use of internal fixation is not responsible for excessive morbidity, provided debridement and lavage are performed. Civilian ballistic fractures, when they are caused by low-velocity firearms, differ from military ballistic fractures. Although the principle of surgical debridement and lavage remains the same, bone stabilization is different and is similar to conventional open fractures. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  16. Trichophyton rubrum osteomyelitis after calcaneus external fixation pin stabilization of a pilon fracture.

    PubMed

    Waryasz, Gregory R; Bariteau, Jason T

    2014-01-01

    Fungal organisms are an uncommon cause of osteomyelitis, and no dermatophyte osteomyelitis infections have been reported in published studies. We present the case of Trichophyton rubrum osteomyelitis of the calcaneus. Our patient initially presented with a pilon fracture requiring temporary external fixation while awaiting definitive fixation. From our review of the published data, the present case is the first of this type of fungal osteomyelitis to be reported. The patient was evaluated for a left neck mass during his hospitalization that was later found to be consistent with salivary duct carcinoma of the tail of the parotid gland. A left neck dissection and superficial excision of the parotid gland was performed after fixation of his pilon fracture. Subsequently, he developed an increasing lucency in the calcaneus and symptoms of pain and erythema months after the calcaneus pin had been removed. The osteomyelitis was treated with surgical debridement and 3 months of itraconazole once cultures had definitively grown T. rubrum. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Cosmetic arm lengthening with monorail fixator.

    PubMed

    Agrawal, Hemendra Kumar; Singh, Balvinder; Garg, Mohit; Khatkar, Vipin; Batra, Sumit; Sharma, Vinod Kumar

    2015-01-01

    Upper limb length discrepancy is a rare occurrence. Humerus shortening may need specialized treatment to restore the functional and cosmetic status of upper limb. We report a case of humerus lengthening of 9 cm with a monorail external fixator and the result was observed during a 2-year follow-up. Humerus lengthening needs specialized focus as it is not only a cosmetic issue but also a functional demand. The monorail unilateral fixator is more functional and cosmetically acceptable, and thus becomes an effective treatment option.

  18. [Treatment of posttraumatic cubitus varus in children and adolescents. Supracondylar humeral osteotomy using radial external fixation].

    PubMed

    Slongo, T

    2015-06-01

    Precise adaptable fixation of a supracondylar humerus osteotomy with a radial/lateral external fixator to correct posttraumatic cubitus varus. Acquired, posttraumatic cubitus varus as a result of a malhealed and unsatisfactorily treated supracondylar humerus fracture. Idiopathic, congenital cubitus varus (very seldom) if the child (independent of age and after complete healing) is cosmetically impaired; stability of the elbow is reduced due to malalignment (hyperextension); secondary problems and pain (e. g., irritation of the ulnar nerve) are expected or already exist; or there is an explicit wish of the child/parents (relative indication). In principle there are no contraindications provided that the indication criteria are filled. The common argument of age does not represent a contraindication in our opinion, since angular remodeling at the distal end of the humerus is practically nonexistent. Basically, the surgical technique of the radial external fixator is used as previously described for stabilization of complex supracondylar humeral fractures. With the patient in supine position, the arm is placed freely on an arm table. Using a 4-5 cm long skin incision along the radial, supracondylar, the extracapsular part of the distal humerus is prepared, whereby great caution regarding the radial nerve is advised. In contrast to the procedure used in radial external fixation for supracondylar humeral fracture treatment, two Schanz screws are always fixed in each fragment at a distance of 1.5-2 cm. The osteotomy must allow the fragment to freely move in all directions. The proximal and distal two Schanz screws are then connected with short 4 mm carbon or stainless steel rods. These two rods are connected with each other over another rod using the tub-to-tub technique. Now the preliminary correction according the clinical situation can be performed and the clamps are tightened. Anatomical axis and function are checked. If these are radiologically and clinically perfect, all clamps are definitively tightened; if the alignment or the function is not perfect, then further adjustments can be made. Due to the excellent stability, further immobilization not necessary. Immediate functional follow-up treatment performed according to pain. Adequate healing is usually expected within 6 weeks. At this time the external fixator can be removed in the fracture clinic. Because the whole operation is performed in an extraarticular manner and the mobility of the elbow is not affected, deterioration of function has never been observed. Also regarding the cosmetic/anatomical situation, good results are expected because they were already achieved intraoperatively.

  19. Finite element analysis and cadaveric cinematic analysis of fixation options for anteriorly implanted trabecular metal interbody cages.

    PubMed

    Berjano, Pedro; Blanco, Juan Francisco; Rendon, Diego; Villafañe, Jorge Hugo; Pescador, David; Atienza, Carlos Manuel

    2015-11-01

    To assess, with finite element analysis and an in vitro biomechanical study in cadaver, whether the implementation of an anterior interbody cage made of hedrocel with nitinol shape memory staples in compression increases the stiffness of the stand-alone interbody cage and to compare these constructs' stiffness to other constructs common in clinical practice. A biomechanical study with a finite element analysis and cadaveric testing assessed the stiffness of different fixation modes for the L4-L5 functional spinal unit: intact spine, destabilized spine with discectomy, posterior pedicle-screw fixation, anterior stand-alone interbody cage, anterior interbody cage with bilateral pedicle screws and anterior interbody cage with two shape memory staples in compression. These modalities of vertebral fixation were compared in four loading modes (flexion, extension, lateral bending, and axial rotation). The L4-L5 spinal unit with an anterior interbody cage and two staples was stiffer than the stand-alone cage. The construct stiffness was similar to that of a model of posterior pedicular stabilization. The stiffness was lower than that of the anterior cage plus bilateral pedicle-screw fixation. The use of an anterior interbody implant with shape memory staples in compression may be an alternative to isolated posterior fixation and to anterior isolated implants, with increased stiffness.

  20. Vibration Testing Procedures for Bone Stiffness Assessment in Fractures Treated with External Fixation.

    PubMed

    Mattei, Lorenza; Longo, Antonia; Di Puccio, Francesca; Ciulli, Enrico; Marchetti, Stefano

    2017-04-01

    A bone healing assessment is crucial for the successful treatment of fractures, particularly in terms of the timing of support devices. However, in clinical practice, this assessment is only made qualitatively through bone manipulation and X-rays, and hence cannot be repeated as often as might be required. The present study reconsiders the quantitative method of frequency response analysis for healing assessments, and specifically for fractures treated with an external fixator. The novelty consists in the fact that bone excitation and response are achieved through fixator pins, thus overcoming the problem of transmission through soft-tissues and their damping effect. The main objective was to develop and validate a test procedure in order to characterize the treated bone. More than 80 tests were performed on a tibia phantom alone, a phantom with pins, and a phantom with a complete fixator. Different excitation techniques and input-output combinations were compared. The results demonstrated the effectiveness of a procedure based on impact tests using a micro-hammer. Pins and fixator were demonstrated to influence the frequency response of the phantom by increasing the number of resonant frequencies. This procedure will be applied in future studies to monitor healing both in in vitro and in vivo conditions.

  1. The effect of HIV on early wound healing in open fractures treated with internal and external fixation.

    PubMed

    Aird, J; Noor, S; Lavy, C; Rollinson, P

    2011-05-01

    There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to internal or external fixation of open fractures in this population, as HIV is not a significant risk factor for acute wound/implant infection. However, subgroup analysis of grade I open fractures in patients with advanced HIV and a low CD4 count (< 350) showed an increased risk of infection; we suggest that grade I open fractures in patients with advanced HIV should be treated by early debridement followed by fixation at an appropriate time.

  2. Syndesmotic fixation in supination-external rotation ankle fractures: a prospective randomized study.

    PubMed

    Kortekangas, Tero H J; Pakarinen, Harri J; Savola, Olli; Niinimäki, Jaakko; Lepojärvi, Sannamari; Ohtonen, Pasi; Flinkkilä, Tapio; Ristiniemi, Jukka

    2014-10-01

    This study compared mid-term functional and radiologic results of syndesmotic transfixation with no fixation in supination external rotation (SER) ankle fractures with intraoperatively confirmed syndesmosis disruption. Our hypothesis was that early-stage good functional results would remain and unfixed syndesmosis disruption in SER IV ankle fractures would not lead to an increased incidence of osteoarthritis. A prospective study of 140 operatively treated patients with Lauge-Hansen SER IV (Weber B) ankle fractures was performed. After bony fixation, the 7.5-Nm standardized external rotation stress test for both ankles was performed under fluoroscopy. A positive stress examination was defined as a difference of more than 2 mm side-to-side in the tibiotalar or tibiofibular clear spaces on mortise radiographs. The patients were randomized to either syndesmotic screw fixation (13 patients) or no syndesmotic fixation (11 patients). After a minimum of 4 years of follow-up (mean, 58 months), ankle function and pain (Olerud-Molander, a 100-mm visual analogue scale [VAS] for ankle function and pain) and quality of life (RAND-36) of all 24 patients were assessed. Ankle joint congruity and osteoarthritis were assessed using mortise and lateral projection plain weight-bearing radiographs and magnetic resonance imaging (MRI; 3T) scans. Improvement in Olerud-Molander score, VAS, and RAND-36 showed no significant difference between groups during the follow-up. In the syndesmotic transfixation group, improvements in all functional parameters and pain measurements were not significant, whereas in the group without syndesmotic fixation, the Olerud-Molander score improved from 84 to 93 (P = .007) and the pain (VAS) score improved from 11 to 4 (P = .038) from 1 year to last follow-up. X-ray or MRI imaging showed no difference between groups at the last follow-up visit. With the numbers available, no significant difference in functional outcome or radiologic findings could be detected between syndesmosis transfixation and no-fixation patients with SER IV ankle fracture after a minimum of 4 years of follow-up. Level II, prospective comparative study. © The Author(s) 2014.

  3. Novel Use of Active Leptospermum Honey for Ringed Fixator Pin Site Care in Diabetic Charcot Deformity Patients.

    PubMed

    Lazarides, Alexander L; Hamid, Kamran S; Kerzner, Michael S

    2018-04-01

    Open reduction with external fixation (OREF) utilizing fine wire ringed fixators for correction of Charcot deformity has gained popularity over the past decade. Pin site infections are a well-documented complication of external fixation as well as a driver of escalating health care costs. We aimed to demonstrate the safety and efficacy of a novel method of pin site care utilizing active Leptospermum honey-impregnated dressings (MediHoney) in diabetic patients undergoing deformity correction with OREF. Twenty-one diabetic patients with Charcot deformities of the lower extremity were prospectively enrolled and followed for pin site complications following OREF for deformity correction. Active Leptospermum honey dressings were applied at metal-cutaneous interfaces at the end of the OREF procedure and replaced weekly for a total of 8 weeks. Patients were monitored for pin site infections from the time of surgery until external fixator removal. Sixteen consecutive patients receiving standard OREF for Charcot deformities were evaluated retrospectively to serve as a control group. Of the 21 enrolled patients, 19 underwent OREF and followed up throughout the study period. Treated patients had a mean age of 58.5 years and mean body mass index measuring 33.3 kg/m 2 as documented prior to surgery. The 15 patients with hemoglobin A1c labs drawn in the 3 months preceding surgery averaged 7.5. Fixators were removed at an average of 12.1 weeks after adequate bony healing. Of the 244 pin sites in 19 patients, 3 pin sites (1.2% of pins) in 2 patients (10.5% of patients) showed evidence of superficial infection. All infections resolved with oral antibiotics. Infection rates were significantly reduced when compared to the standard care control group. Pilot data in a prospectively collected case series demonstrate safety and efficacy of active Leptospermum honey-impregnated dressings when used for fine wire ringed fixator pin site care in diabetic Charcot deformity patients. Further investigation in the form of a prospective randomized controlled study is warranted to demonstrate the potential value of this novel intervention. Level IV.

  4. Role of Joshi's external stabilization system with percutaneous screw fixation in high-energy tibial condylar fractures associated with severe soft tissue injuries.

    PubMed

    Gupta, Ashish-Kumar; Sapra, Rahul; Kumar, Rakesh; Gupta, Som-Prakash; Kaushik, Devwart; Gaba, Sahil; Bansal, Mahesh Chand; Dayma, Ratan Lal

    2015-01-01

    The treatment of high-energy tibial condylar fractures which are associated with severe soft tissue injuries remains contentious and challenging. In this study, we assessed the results of Joshi's external stabilization system (JESS) by using the principle of ligamentotaxis and percutaneous screw fixation for managing high-energy tibial condylar fractures associated with severe soft tissue injuries. Between June 2008 and June 2010, 25 consecutive patients who were 17e71 years (mean, 39.7), underwent the JESS fixation for high-energy tibial condylar fractures associated with severe soft tissue injuries. Out of 25 patients, 2 were lost during follow-up and in 1 case early removal of frame was done, leaving 22 cases for final follow-up. Among them, 11 had poor skin condition with abrasions and blisters and 2 were open injuries (Gustilo-Anderson grade I&II). The injury mechanisms were motor vehicle accidents (n=19), fall from a height (n=2) and assault (n=1). The fractures were classified according to Schatzker classification system. There were 7 type-V, 14 type-VI and 1 type-lV Schatzker's tibial plateau fractures. The average interval between the injury and surgery was 6.8 days (range 2-13). The average hospital stay was 13 days (range, 7-22). The average interval between the surgery and full weight bearing was 13.6 weeks (range 11-20). The average range of knee flexion was 121°(range 105°-135°). The normal extension of the knee was observed in 20 patients, and an extensor lag of 5°-8° was noted in 2 patients. The complications included superficial pin tract infections (n=4) with no knee stiffness. JESS with lag screw fixation combines the benefit of traction, external fixation, and limited internal fixation, at the same time as allowing the ease of access to the soft tissue for wound checks, pin care, dressing changes, measurement of compartment pressure, and the monitoring of the neurovascular status. In a nutshell, JESS along with screw fixation offers a promising alternative treatment for high- energy tibial condylar fractures associated with severe soft tissue injuries.

  5. Management of tibial fractures using a circular external fixator in two calves.

    PubMed

    Aithal, Hari Prasad; Kinjavdekar, Prakash; Amarpal; Pawde, Abhijit Motiram; Singh, Gaj Raj; Setia, Harish Chandra

    2010-07-01

    To report the repair of tibial diaphyseal fractures in 2 calves using a circular external skeletal fixator (CEF). Clinical report. Crossbred calves (n=2; age: 6 months; weight: 55 and 60 kg). Mid-diaphyseal tibial fractures were repaired by the use of a 4-ring CEF (made of aluminum rings with 2 mm K-wires) alone in 1 calf and in combination with hemicerclage wiring in 1 calf. Both calves had good weight bearing with moderate lameness postoperatively. Fracture healing occurred by day 60 in 1 calf and by day 30 in calf 2. The CEF was well maintained and tolerated by both calves through fracture healing. Joint mobility and limb usage improved gradually after CEF removal. CEF provided a stable fixation of tibial fractures and healing within 60 days and functional recovery within 90 days. CEF can be safely and successfully used for the management of selected tibial fractures in calves.

  6. Biological approach to treatment of intra-articular proximal tibial fractures with double osteosynthesis.

    PubMed

    Singh, Saurabh; Patel, Pankaj R; Joshi, Anil Kumar; Naik, Rajnikant N; Nagaraj, Chethan; Kumar, Sudeep

    2009-02-01

    The treatment of intra-articular proximal tibial fractures is associated with complications, and much conflicting literature exists concerning the treatment of choice. In our study, an attempt has been made to develop an ideal and adequate treatment protocol for these intra-articular fractures. The principle of double osteosynthesis, i.e., lateral minimally invasive plate osteosynthesis (MIPO), was combined with a medial external fixator to treat 22 intra-articular proximal tibial fractures with soft tissue injury with a mean follow-up of 25 months. Superficial pin track infection was observed in one case, and no soft tissue breakdown was noted. Loss of articular reconstruction was reported in one case. Bridging callus was seen at 12 weeks (8 weeks-7 months). The principle of substitution or double osteosynthesis, i.e., lateral MIPO, was combined with a medial external fixator and proved to be a fairly good method of fixation in terms of results and complications.

  7. Correction of a Hyperextension Deformity at the Metacarpophalangeal Joint by Arthroplasty for Osteoarthritis of the Thumb Carpometacarpal Joint Followed by External Fixator: A Case Series: Modified Ilizarov Method for Correction of a Collapsed Thumb Deformity Due to Carpometacarpal Osteoarthritis.

    PubMed

    Hamada, Yoshitaka; Kobayashi, Anna; Sairyo, Koichi; Sato, Ryosuke; Hibino, Naohito

    2015-06-01

    A hyperextension deformity in the advanced stages of carpometacarpal (CMC) arthritis of the thumb could affect the outcomes of thumb CMC joint arthroplasty. We introduce the interesting approach for treating severely collapsed thumb deformities with gradual distraction and coordinated correction of the MCP and CMC joints by means of external fixators. We divided 8 cases into 3 groups according to the angle of passive flexion of the hyperextended MCP joint: group 1, 10-20°, group 2a, 20-40°, and group 2b, >40°, retrospectively. We first performed CMC arthroplasty with trapezium excision. In group 1, we corrected the MCP hyperextension deformity by manual passive flexion and fixed the joint with an extension block Kirshner wire (K-wire) for 2 months. However, deformities recurred in 2 of 5 cases after removing the K-wire. These patients received corrective percutaneous osteotomy with external fixators at the metacarpal neck. In groups 2a and 2b, we performed CMC arthroplasty and set external fixators at the same time. All cases in groups 1 and 2a have been without recurrence for more than 2 years, while a deformity recurred in group 2b. The results of this small case series encouraged us to propose an interesting approach for collapsed zigzag thumb deformity. Good outcomes with excellent maintenance of active MCP movement and no recurrence are highly anticipated if the hyperextended thumb has no obvious degenerative changes and can be corrected by <40° of passive flexion. Our results also indicate a risk of recurrence associated with extension block by K-wire.

  8. Regenerate bone fracture rate following femoral lengthening in paediatric patients

    PubMed Central

    Burke, N. G.; Cassar-Gheiti, A. J.; Tan, J.; McHugh, G.; O’Neil, B. J.; Noonan, M.; Moore, D.

    2017-01-01

    Abstract Purpose Femoral lengthening using a circular or mono-lateral frame is a commonly used technique. Fracture at the site of the regenerate bone is a major concern especially following removal of the external fixator. This aim of this study was to assess the rate of fracture of the regenerate bone in this single surgeon series of paediatric patients and determine potential risk factors. Methods Retrospective review of all the femoral lengthening performed by the senior author was performed. The medical and physiotherapy notes were reviewed. The gender, age at time of surgery, disease aetiology, total days in the external fixator and length of the new regenerate bone were recorded. Patients who sustained a regenerate fracture were identified. Results A total of 176 femoral lengthening procedures were performed on 108 patients. Eight regenerate fractures occurred in seven patients (4.5%). The mechanism of injury was a fall in five cases and during physiotherapy in three cases. The regenerate fracture occurred a median number of nine days following removal of frame. There was no significant difference between gender, age at time of surgery, total time in external fixator between those who sustained a regenerate fracture and those patients who did not. A significant difference was noted between the amount of lengthening between the ‘regenerate fracture group’ and the ‘no fracture group’ (50 mm vs 38 mm, respectively; p = 0.029). There was no association between disease aetiology and risk of regenerate fracture. Conclusions Femoral lengthening of more than 50 mm increases the risk of a fracture at the regenerate site regardless of the disease aetiology. We recommend avoidance of aggressive physiotherapy for the initial four weeks following external fixator removal. PMID:28828065

  9. Safety evaluation of large external fixation clamps and frames in a magnetic resonance environment.

    PubMed

    Luechinger, Roger; Boesiger, Peter; Disegi, John A

    2007-07-01

    Large orthopedic external fixation clamps and related components were evaluated for force, torque, and heating response when subjected to the strong electromagnetic fields of magnetic-resonance (MR) imaging devices. Forces induced by a 3-Tesla (T) MR scanner were compiled for newly designed nonmagnetic clamps and older clamps that contained ferromagnetic components. Heating trials were performed in a 1.5 and in a 3 T MR scanner with two assembled external fixation frames. Forces of the newly designed clamps were more than a factor 2 lower as the gravitational force on the device whereas, magnetic forces on the older devices showed over 10 times the force induced by earth acceleration of gravity. No torque effects could be found for the newly designed clamps. Temperature measurements at the tips of Schanz screws in the 1.5 T MR scanner showed a rise of 0.7 degrees C for a pelvic frame and of 2.1 degrees C for a diamond knee bridge frame when normalized to a specific absorption rate (SAR) of 2 W/kg. The normalized temperature increases in the 3 T MR scanner were 0.9 degrees C for the pelvic frame and 1.1 degrees C for the knee bridge frame. Large external fixation frames assembled with the newly designed clamps (390 Series Clamps), carbon fiber reinforced rods, and implant quality 316L stainless steel Schanz screws met prevailing force and torque limits when tested in a 3-T field, and demonstrated temperature increase that met IEC-60601 guidelines for extremities. The influence of frame-induced eddy currents on the risk of peripheral nerve stimulation was not investigated. Copyright 2006 Wiley Periodicals, Inc.

  10. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation

    PubMed Central

    Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750

  11. Radial and tibial fracture repair with external skeletal fixation. Effects of fracture type, reduction, and complications on healing.

    PubMed

    Johnson, A L; Kneller, S K; Weigel, R M

    1989-01-01

    Twenty-eight consecutive fractures of the canine radius and tibia were treated with external skeletal fixation as the primary method of stabilization. The time of fixation removal (T1) and the time to unsupported weight-bearing (T2) were correlated with: (1) bone involved; (2) communication of the fracture with the external environment; (3) severity of the fracture; (4) proximity of the fracture to the nutrient artery; (5) method of reduction; (6) diaphyseal displacement after reduction; and (7) gap between cortical fragments after reduction. The Kruskal-Wallis one-way analysis of variance was used to test the correlation with p less than .05 set as the criterion for significance. The median T1 was 10 weeks and the median T2 was 11 weeks. None of the variables correlated significantly with either of the healing times; however, there was a strong trend toward longer healing times associated with open fractures and shorter healing times associated with closed reduction. Periosteal and endosteal callus uniting the fragments were observed radiographically in comminuted fractures, with primary bone union observed in six fractures in which anatomic reduction was achieved. Complications observed in the treatment of these fractures included: bone lysis around pins (27 fractures), pin track drainage (27 fractures), pin track hemorrhage (1 fracture), periosteal reaction around pins (27 fractures), radiographic signs consistent with osteomyelitis (12 fractures), degenerative joint disease (2 dogs), and nonunion (1 fracture). Valgus or rotational malalignment resulted in 16 malunions of fractures. One external fixation device was replaced and four loose pins were removed before the fractures healed. One dog was treated with antibiotics during the postoperative period because clinical signs of osteomyelitis appeared.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Percutaneous external fixator pins with bactericidal micron-thin sol-gel films for the prevention of pin tract infection.

    PubMed

    Qu, Haibo; Knabe, Christine; Radin, Shula; Garino, Jonathan; Ducheyne, Paul

    2015-09-01

    Risk of infection is considerable in open fractures, especially when fracture fixation devices are used to stabilize the fractured bones. Overall deep infection rates of 16.2% have been reported. The infection rate is even greater, up to 32.2%, with external fixation of femoral fractures. The use of percutaneous implants for certain clinical applications, such as percutaneous implants for external fracture fixation, still represents a challenge today. Currently, bone infections are very difficult to treat. Very potent antibiotics are needed, which creates the risk of irreversible damage to other organs, when the antibiotics are administered systemically. As such, controlled, local release is being pursued, but no such treatments are in clinical use. Herein, the use of bactericidal micron-thin sol-gel films on metallic fracture fixation pins is reported. The data demonstrates that triclosan (2,4,4'-trichloro-2'-hydroxydiphenylether), an antimicrobial agent, can be successfully incorporated into micron-thin sol-gel films deposited on percutaneous pins. The sol-gel films continuously release triclosan in vitro for durations exceeding 8 weeks (longest measured time point). The bactericidal effect of the micron-thin sol-gel films follows from both in vitro and in vivo studies. Inserting percutaneous pins in distal rabbit tibiae, there were no signs of infection around implants coated with a micron-thin sol-gel/triclosan film. Healing had progressed normally, bone tissue growth was normal and there was no epithelial downgrowth. This result was in contrast with the results in rabbits that received control, uncoated percutaneous pins, in which abundant signs of infection and epithelial downgrowth were observed. Thus, well-adherent, micron-thin sol-gel films laden with a bactericidal molecule successfully prevented pin tract infection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. A biomechanical evaluation to optimize the configuration of a hinged external fixator for the primary treatment of severely displaced intraarticular calcaneus fractures with soft tissue damage.

    PubMed

    Besch, Lutz; Schmidt, Ina; Mueller, Michael; Daniels-Wredenhagen, Mark; Hilgert, Ralf-Eric; Varoga, Deike; Seekamp, Andreas

    2008-01-01

    The purpose of this investigation was to develop an optimized hinged external fixator for the primary treatment of dislocated, intra-articular calcaneus fractures with associated soft tissue damage. To this end, a calcaneus model was made out of a polyurethane block, and a steel cylinder served as the ankle joint and was connected to a synthetic model of the tibia via a metal clamp. A saw cut served as the fracture in the model. A Steinmann nail and Schanz screw were placed in defined positions in the model and connected medially and laterally with longitudinal support rods. The fixator allowed a total of 20 degrees of plantar- and dorsiflexion, with rotation in the virtual axis of the upper ankle joint. Changes in the model fracture were measured during cyclical strain, and at different screw positions in the model tibia and calcaneus. Miniature force sensors located on the longitudinal support rods, and a plantar tension spring, were used to measure pressure and tension. Reproducible values were determined and, with the optimal configuration, shifting within the osteotomy was minimal. In the experimental configuration, optimal tibial screw placement was 70 mm proximal to the rotation axis of the upper ankle joint, and optimal placement of the Steinmann nail was in the posterior surface of the calcaneus. These findings indicated that the hinged fixator allows 20 degrees of ankle movement without alteration of the rotation axis, and suggest that this type of external fixator can be used in all types of calcaneal fracture regardless of the soft tissue damage. ACFAS Level of Clinical Evidence: 5c.

  14. Minimally invasive surgical technique: Percutaneous external fixation combined with titanium elastic nails for selective treatment of tibial fractures.

    PubMed

    Tu, Kai-Kai; Zhou, Xian-Ting; Tao, Zhou-Shan; Chen, Wei-Kai; Huang, Zheng-Liang; Sun, Tao; Zhou, Qiang; Yang, Lei

    2015-12-01

    Several techniques have been described to treat tibial fractures, which respectively remains defects. This article presents a novel intra- and extramedullary fixation technique: percutaneous external fixator combined with titanium elastic nails (EF-TENs system). The purpose of this study is to introduce this new minimally invasive surgical technique and selective treatment of tibial fractures, particularly in segmental fractures, diaphysis fractures accompanied with distal or proximal bone subfissure, or fractures with poor soft-tissue problems. Following ethical approval, thirty-two patients with tibial fractures were treated by the EF-TENs system between January 2010 and December 2012. The follow-up studies included clinical and radiographic examinations. All relevant outcomes were recorded during follow-up. All thirty-two patients were achieved follow-ups. According to the AO classification, 3 Type A, 9 Type B and 20 Type C fractures were included respectively. According to the Anderson-Gustilo classification, there were 5 Type Grade II, 3 Type Grade IIIA and 2 Type Grade IIIB. Among 32 patients, 8 of them were segmental fractures. 12 fractures accompanied with bone subfissure. Results showed no nonunion case, with an average time of 23.7 weeks (range, 14-32 weeks). Among them, there were 3/32 delayed union patients and 0/32 malunion case. 4/32 patients developed a pin track infection and no patient suffered deep infection. The external fixator was removed with a mean time of 16.7 weeks (range, 10-26 weeks). Moreover, only 1/32 patient suffered with the restricted ROM of ankle, none with the restricted ROM of knee. This preliminary study indicated that the EF-TENs system, as a novel intra- and extramedullary fixation technique, had substantial effects on selective treatment of tibial fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. More visual mind wandering occurrence during visual task performance: Modality of the concurrent task affects how the mind wanders.

    PubMed

    Choi, HeeSun; Geden, Michael; Feng, Jing

    2017-01-01

    Mind wandering has been considered as a mental process that is either independent from the concurrent task or regulated like a secondary task. These accounts predict that the form of mind wandering (i.e., images or words) should be either unaffected by or different from the modality form (i.e., visual or auditory) of the concurrent task. Findings from this study challenge these accounts. We measured the rate and the form of mind wandering in three task conditions: fixation, visual 2-back, and auditory 2-back. Contrary to the general expectation, we found that mind wandering was more likely in the same form as the task. This result can be interpreted in light of recent findings on overlapping brain activations during internally- and externally-oriented processes. Our result highlights the importance to consider the unique interplay between the internal and external mental processes and to measure mind wandering as a multifaceted rather than a unitary construct.

  16. More visual mind wandering occurrence during visual task performance: Modality of the concurrent task affects how the mind wanders

    PubMed Central

    Choi, HeeSun; Geden, Michael

    2017-01-01

    Mind wandering has been considered as a mental process that is either independent from the concurrent task or regulated like a secondary task. These accounts predict that the form of mind wandering (i.e., images or words) should be either unaffected by or different from the modality form (i.e., visual or auditory) of the concurrent task. Findings from this study challenge these accounts. We measured the rate and the form of mind wandering in three task conditions: fixation, visual 2-back, and auditory 2-back. Contrary to the general expectation, we found that mind wandering was more likely in the same form as the task. This result can be interpreted in light of recent findings on overlapping brain activations during internally- and externally-oriented processes. Our result highlights the importance to consider the unique interplay between the internal and external mental processes and to measure mind wandering as a multifaceted rather than a unitary construct. PMID:29240817

  17. Unilateral fixation for treatment of occipitocervical instability in children with congenital vertebral anomalies of the craniocervical junction.

    PubMed

    Mazur, Marcus D; Ravindra, Vijay M; Brockmeyer, Douglas L

    2015-04-01

    OBJECT Patients with occipitocervical (OC) instability from congenital vertebral anomalies (CVAs) of the craniocervical junction (CCJ) often have bony abnormalities that make instrumentation placement difficult. Within this patient population, some bilateral instrumentation constructs either fail or are not feasible, and a unilateral construct must be used. The authors describe the surgical management and outcomes of this disorder in patients in whom unilateral fixation constructs were used to treat OC instability. METHODS From a database of OC fusion procedures, the authors identified patients who underwent unilateral fixation for the management of OC instability. Patient characteristics, surgical details, and radiographic outcomes were reviewed. In each patient, CT scans were performed at least 4 months after surgery to evaluate for fusion. RESULTS Eight patients with CVAs of the CCJ underwent unilateral fixation for the treatment of OC instability. For 4 patients, the procedure occurred after a bilateral OC construct failed or infection forced hardware removal. For the remainder, it was the primary procedure. Two patients required reoperation for hardware revision and 1 developed nonunion requiring revision of the bone graft. Ultimately, 7 patients demonstrated osseous fusion on CT scans and 1 had a stable fibrous union. CONCLUSIONS These findings demonstrate that a unilateral OC fixation is effective for the treatment of OC instability in children with CVAs of the CCJ in whom bilateral screw placement fails or is not feasible.

  18. A biomechanical comparison of 2 technical variations of double-row rotator cuff fixation: the importance of medial row knots.

    PubMed

    Busfield, Benjamin T; Glousman, Ronald E; McGarry, Michelle H; Tibone, James E; Lee, Thay Q

    2008-05-01

    Previous studies have shown comparable biomechanical properties of double-row fixation versus double-row fixation with a knotless lateral row. SutureBridge is a construct that secures the cuff with medial row mattress suture anchors and knotless lateral row fixation of the medial suture ends. Recent completely knotless constructs may lead to lesser clinical outcomes if the construct properties are compromised from lack of suture knots. A completely knotless construct without medial row knots will compromise the biomechanical properties in both cyclic and failure-testing parameters. Controlled laboratory study. Six matched pairs of cadaveric shoulders were randomized to 2 groups of double row fixation with SutureBridge: group 1 with medial row knots, and group 2 without medial row knots. The specimens were placed in a materials test system at 30 degrees of abduction. Cyclic testing to 180 N at 1 mm/sec for 30 cycles was performed, followed by tensile testing to failure at 1 mm/sec. Data included cyclic and failure data from the materials test system and gap data using a video digitizing system. All data from paired specimens were compared using paired Student t tests. Group 1 had a statistically significant difference (P < .05) for gap formation for the 1st (3.47 vs 5.05 mm) and 30th cycle (4.22 vs 8.10 mm) and at yield load (5.2 vs 9.1 mm). In addition, there was a greater energy absorbed (2805 vs 1648 N-mm), yield load (233 vs 183.1 N), and ultimate load (352.9 vs 253.9 N) for group 1. The mode of failure for the majority (4/6) of group 2 was lateral row failure, whereas all group 1 specimens failed at the clamp. Although lateral row knotless fixation has been shown not to sacrifice structural integrity of this construct, the addition of a knotless medial row compromises the construct leading to greater gapping and failure at lower loads. This may raise concerns regarding recently marketed completely knotless double row constructs.

  19. Is lateral stabilization enough in thoracolumbar burst fracture reconstruction? A biomechanical investigation.

    PubMed

    Panchal, Ripul R; Matheis, Erika A; Gudipally, Manasa; Hussain, Mir M; Kim, Kee D; Bucklen, Brandon S

    2015-10-01

    Traditional reconstruction for burst fractures involves columnar support with posterior fixation at one or two levels cephalad/caudad; however, some surgeons choose to only stabilize the vertebral column. The aim was to distinguish biomechanical differences in stability between a burst fracture stabilized through a lateral approach using corpectomy spacers of different end plate sizes with and without integrated screws and with and without posterior fixation. This was an in vitro biomechanical study assessing thoracolumbar burst fracture stabilization. Six human spines (T11-L3) were tested on a six-degrees-of-freedom simulator enabling unconstrained range of motion (ROM) at ±6 N·m in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) after a simulated burst fracture at L1. Expandable corpectomy spacers with/without integrated screws (Fi/F; FORTIFY Integrated/FORTIFY; Globus Medical, Inc., Audubon, PA, USA) were tested with different end plate sizes (21×23 mm, 22×40-50 mm). Posterior instrumentation (PI) via bilateral pedicle screws and rods was used one level above and one level below the burst fracture. Lateral plate (LP) fixation was tested. Devices were tested in the following order: intact; Fi21×23; Fi21×23+PI; F21×23+PI+LP; F21×23+LP; F22×40-50+LP; F22×40-50+PI+LP; Fi22×40-50+PI; Fi22×40-50. In FE and AR, constructs without PI showed no significant difference (p<.05) in stability compared with intact. In LB, F22×40-50+LP showed a significant increase in stability relative to intact, but no other construct without PI reached significance. In FE and LB, circumferential constructs were significantly more stable than intact. In AR, no construct showed significant differences in motion when compared with the intact condition. Constructs without posterior fixation were the least stable of all tested constructs. Circumferential fixation provided greater stability in FE and LB than lateral fixation and intact. Axial rotation showed no significant differences in any construct compared with the intact state. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Intraoperative assessment of the stability of the distal tibiofibular joint in supination-external rotation injuries of the ankle: sensitivity, specificity, and reliability of two clinical tests.

    PubMed

    Pakarinen, Harri; Flinkkilä, Tapio; Ohtonen, Pasi; Hyvönen, Pekka; Lakovaara, Martti; Leppilahti, Juhana; Ristiniemi, Jukka

    2011-11-16

    This study was designed to assess the sensitivity, specificity, and interobserver reliability of the hook test and the stress test for the intraoperative diagnosis of instability of the distal tibiofibular joint following fixation of ankle fractures resulting from supination-external rotation forces. We conducted a prospective study of 140 patients with an unstable unilateral ankle fracture resulting from a supination-external rotation mechanism (Lauge-Hansen SE). After internal fixation of the malleolar fracture, a hook test and an external rotation stress test under fluoroscopy were performed independently by the lead surgeon and assisting surgeon, followed by a standardized 7.5-Nm external rotation stress test of each ankle under fluoroscopy. A positive stress test result was defined as a side-to-side difference of >2 mm in the tibiotalar or the tibiofibular clear space on mortise radiographs. The sensitivity and specificity of each test were calculated with use of the standardized 7.5-Nm external rotation stress test as a reference. Twenty-four (17%) of the 140 patients had a positive standardized 7.5-Nm external rotation stress test after internal fixation of the malleolar fracture. The hook test had a sensitivity of 0.25 (95% confidence interval, 0.12 to 0.45) and a specificity of 0.98 (95% confidence interval, 0.94 to 1.0) for the detection of the same instabilities. The external rotation stress test had a sensitivity of 0.58 (95% confidence interval, 0.39 to 0.76) and a specificity of 0.96 (95% confidence interval, 0.90 to 0.98). Both tests had excellent interobserver reliability, with 99% agreement for the hook test and 98% for the stress test. Interobserver agreement for the hook test and the clinical stress test was excellent, but the sensitivity of these tests was insufficient to adequately detect instability of the syndesmosis intraoperatively.

  1. Photoactive TiO2 antibacterial coating on surgical external fixation pins for clinical application

    PubMed Central

    Villatte, Guillaume; Massard, Christophe; Descamps, Stéphane; Sibaud, Yves; Forestier, Christiane; Awitor, Komla-Oscar

    2015-01-01

    External fixation is a method of osteosynthesis currently used in traumatology and orthopedic surgery. Pin tract infection is a common problem in clinical practice. Infection occurs after bacterial colonization of the pin due to its contact with skin and the local environment. One way to prevent such local contamination is to create a specific coating that could be applied in the medical field. In this work, we developed a surface coating for external fixator pins based on the photocatalytic properties of titanium dioxide, producing a bactericidal effect with sufficient mechanical strength to be compatible with surgical use. The morphology and structure of the sol-gel coating layers were characterized using, respectively, scanning electron microscopy and X-ray diffraction. The resistance properties of the coating were investigated by mechanical testing. Photodegradation of acid orange 7 in aqueous solution was used as a probe to assess the photocatalytic activity of the titanium dioxide layers under ultraviolet irradiation. The bactericidal effect induced by the process was evaluated against two strains, ie, Staphylococcus aureus and multiresistant Staphylococcus epidermidis. The coated pins showed good mechanical strength and an efficient antibacterial effect after 1 hour of ultraviolet irradiation. PMID:26005347

  2. Combination of Open Subtotal Calcanectomy and Stabilization With External Fixation as Limb Salvage Procedure in Hindfoot-Infected Diabetic Foot Ulcers.

    PubMed

    Dalla Paola, Luca; Carone, Anna; Boscarino, Giulio; Scavone, Giuseppe; Vasilache, Lucian

    2016-12-01

    Diabetic hindfoot ulcers, complicated by osteomyelitis, are associated with a high risk of major amputation. Partial calcanectomy, preceded by an effective management of the infection and of the eventual peripheral artery disease, can be considered as valid therapeutic option. We have evaluated a therapeutic protocol for diabetic hindfoot ulcers complicated by osteomyelitis, which, besides an adequate surgical debridement, considers a reconstructive pathway assisted by the positioning of a circular external fixator. We made a prospective study of a cohort of diabetic patients affected by heel ulcer complicated by osteomyelitis. All patients underwent open partial calcanectomy associated with the positioning of a circular external frame specifically designed for hindfoot stabilization and offloading. A reconstructive procedure was implemented starting with the application of negative pressure wound therapy and coverage with dermal substitute and split thickness skin grafting. From November 2014 to November 2015, 18 consecutive patients were enrolled. Mean follow-up period was 212.3 ± 64.0 days. Healing was achieved in 18 (100%) patients. The mean healing time was 69.0 ± 64.0 days. No major amputation had to be performed during the follow-up. Open partial calcanectomy associated with external fixation and skin reconstruction was as efficient as limb salvage in patients with infected lesions of the hindfoot complicated by calcaneal osteomyelitis.

  3. A new animal model for bone atrophic nonunion: fixation by external fixator.

    PubMed

    Kaspar, Katharina; Matziolis, Georg; Strube, Patrick; Sentürk, Ufuk; Dormann, Svenja; Bail, Hermann J; Duda, Georg N

    2008-12-01

    A new small animal model of bone atrophic nonunion was established for investigating the process of bone regeneration by performing cauterization of the periosteum, removal of the local bone marrow, and stabilization with external fixation. The model allows the creation of an atrophic nonunion without the need for a critical size defect. Furthermore, it provides reproducible, well-defined mechanical conditions and minimized physical interference of the implant with the biological processes in the healing zone. Eighty adult Sprague-Dawley rats received an osteotomy of the left femur, stabilized with an external fixator. In half of the animals, the periosteum proximal and distal to the osteotomy was destroyed by cauterization and the adjacent bone marrow was removed (nonunion group). At 2 and 8 weeks after surgery, radiological, biomechanical, histological, and histomorphometrical analyses showed a typical physiological healing in the control group, while the nonunion group was characterized by resorption of the bone ends with some callus formation distant to the osteotomy. At both time points, the callus was composed of significantly less bone and significantly more connective tissue (p < 0.001). In addition, the torsional strength of the osteotomized femur was significantly less in the nonunion group than in the control group, which was comparable to that of the intact femur (p < 0.001). In conclusion, the present model allows the induction of an atrophic nonunion without the need of a critical size defect. It is reproducible, provides standardized biomechanical conditions, and allows minimized interaction of the implant with the healing zone.

  4. A scoping review of applications and outcomes of traction orthoses and constructs for the management of intra-articular fractures and fracture dislocations in the hand.

    PubMed

    Packham, Tara L; Ball, Pamela D; MacDermid, Joy C; Bain, James R; DalCin, Arianna

    2016-01-01

    Intra-articular hand fractures can have devastating consequences for movement and function. The unique nature of the injury and diverse management strategies are a challenge for conducting trials. To conduct a scoping review of traction constructs for the management of intra-articular hand fractures. We conducted a systematic search of the literature, extracting data on the scope and nature of the evidence for traction constructs. Our search yielded 87 articles addressing 3 traction constructs: (1) static traction (n = 17), (2) dynamic external fixation (n = 53), and (3) dynamic orthoses (n = 17). Active range of motion of the target joint was the most frequently reported outcome. Study designs included 36 cohorts, 21 case series, and 9 case studies: 24% contained only technical information. The current literature addressing traction constructs consists primarily of small and low-quality studies. Evidence synthesis could improve the estimation of range of motion outcomes but would not be able to identify the best treatment. Consensus on classification of fracture patterns, routine use of outcome measures, and randomized trials are needed to compare different traction constructs and inform evidence-based care. Scoping review. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  5. Incidence of infection after early intramedullary nailing of open tibial shaft fractures stabilized with pinless external fixators

    PubMed Central

    Kulshrestha, Vikas

    2008-01-01

    Background: A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This disadvantage is overcome by the AO pinless fixator, in which the trocar points are clamped onto the outer cortex without penetrating it. This study was designed to evaluate the role of AO pinless fixators in primary stabilization of open diaphyseal tibial fractures that received staged treatment because of delayed presentation or poor general condition. We also analyzed the rate of infection on early conversion to intramedullary nail. Materials and Methods: This study is a retrospective review of 30 open diaphyseal fractures of tibia, which were managed with primary stabilization with pinless fixator and early exchange nailing. Outcome was evaluated in terms of fracture union and rate of residual infection. The data were compared with that available in the literature. Results: All the cases were followed up for a period of 2 years. The study includes Gustilo type 1 (n=10), 14 Gustilo type 2 (n=14), and type3 (n=6) cases. 6 cases (20%) had clamp site infection, 2 cases (6.7%) had deep infection, and in 28 cases (93%) the fracture healed and consolidated well. Conclusion: This study has highlighted the valuable role of pinless external fixator in the management of open tibial fractures in terms of safety and ease of application as well as the advantage of early conversion to intramedullary implant without the risk of deep infection. PMID:19753227

  6. Biomechanical characterization of double-bundle femoral press-fit fixation techniques.

    PubMed

    Ettinger, M; Haasper, C; Hankemeier, S; Hurschler, C; Breitmeier, D; Krettek, C; Jagodzinski, M

    2011-03-01

    Press-fit fixation of patellar tendon bone anterior cruciate ligament autografts is an interesting technique because no hardware is necessary. To date, no biomechanical data exist describing an implant-free double-bundle press-fit procedure. The purpose of this study was to characterize the biomechanical properties of three double-bundle press-fit fixations. In a controlled laboratory study, the patellar-, quadriceps- and hamstring tendons of 10 human cadavers (age: 49.2 ± 18.5 years) were used. An inside out press-fit fixation with a knot in the semitendinosus and gracilis tendons (SG) combined with an additional bone block, with two quadriceps tendon bone block grafts (QU) was compared with press-fit fixation of two bone patellar tendon bone block (PT) grafts in 30 porcine femora. Constructs were cyclically stretched and then loaded until failure. Maximum load to failure, stiffness and elongation during failure testing and cyclical loading were investigated. The maximum load to failure was 703 ± 136 N for SG fixation, 632 ± 130 N for QU and 656 ± 127 N for PT fixation. Stiffness of the constructs averaged 138 ± 26 N/mm for SG, 159 ± 74 N/mm for QU, and 154 ± 50 N/mm for PT fixation. Elongation during initial cyclical loading was 1.2 ± 1.4 mm for SG, 2.0 ± 1.4 mm for QU, and 1.0 ± 0.6 mm for PT (significantly larger for PT and QU between the first 5 cycles compared with cycles 15-20th, P < 0.01). All investigated double-bundle fixation techniques were equal in terms of maximum load to failure, stiffness, and elongation. Unlike with single-bundle press-fit fixation techniques that have been published, no difference was observed between pure tendon combined with an additional bone block and tendon bone grafts. All techniques exhibited larger elongation during initial cyclical loading. All three press-fit fixation techniques that were investigated exhibit comparable biomechanical properties. Preconditioning of the constructs is critical.

  7. Absent pedicles in campomelic dysplasia.

    PubMed

    McDowell, Michael M; Dede, Ozgur; Bosch, Patrick; Tyler-Kabara, Elizabeth C

    2017-06-01

    The objective of the present study is to report a case of campomelic dysplasia illustrating the absence of cervical and thoracic pedicles. This report reiterates the importance of this clinical peculiarity in the setting of spine instrumentation. A 10-year-old female patient with campomelic dysplasia presented with progressive kyphoscoliosis and signs of neural compromise. Imaging studies confirmed thoracic level stenosis and demonstrated absence of multiple pedicles in cervical and thoracic spine. The patient underwent decompression and instrumentation/fusion for her spinal deformity. The patient was instrumented between C2 and L4 with pedicle screws and sublaminar cables. However, pedicle fixation was not possible for the lower cervical and upper-mid thoracic spine. Also, floating posterior elements precluded the use of laminar fixation in the lower cervical spine. Cervicothoracic lumbosacral orthosis (CTLSO) was used for external immobilization to supplement the tenuous fixation in the cervicothoracic area. The patient improved neurologically with no signs of implant failure at the 2-year follow-up. Absence of pedicles and floating posterior elements present a challenge during spine surgery in campomelic dysplasia. Surgeons should prepare for alternative fixation methods and external immobilization when planning on spinal instrumentation in affected patients. Level IV Case Report.

  8. Comparison of two-staged ORIF and limited internal fixation with external fixator for closed tibial plafond fractures.

    PubMed

    Wang, Cheng; Li, Ying; Huang, Lei; Wang, Manyi

    2010-10-01

    To compare the results of two-staged open reduction and internal fixation (ORIF) and limited internal fixation with external fixator (LIFEF) for closed tibial plafond fractures. From January 2005 to June 2007, 56 patients with closed type B3 or C Pilon fractures were randomly allocated into groups I and II. Two-staged ORIF was performed in group I and LIFEF in group II. The outcome measures included bone union, nonunion, malunion, pin-tract infection, wound infection, osteomyelitis, ankle joint function, etc. These postoperative data were analyzed with Statistical Package for Social Sciences (SPSS) 13.0. Incidence of superficial soft tissue infection (involved in wound infection or pin-tract infection) in group I was lower than that in group II (P < 0.05), with significant difference. Group I has significantly less radiation exposure (P < 0.001). Group II had higher rates of malunion, delayed union, and arthritis symptoms, with no statistical significance. Both groups resulted similar ankle joint function. Logistic regression analysis indicated that smoking and fracture pattern were the two factors significantly influencing the final outcomes. In the treatment of closed tibial plafond fractures, both two-staged ORIF and LIFEF offer similar results. Patients undergo LIFEF carry significantly greater radiation exposure and higher superficial soft tissue infection rate (usually occurs on pin tract and does not affect the final outcomes).

  9. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    PubMed

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate constructs and the unlocked IM nail were significantly less with a 50% saw cut depth. Plate fixation was superior to IM nail fixation in limiting the opening of a simulated midtibial stress fracture, and anterior-posterior placement of the plate was an important variable for this construct. Results from these tests can help guide the selection of fixation hardware for patients requiring surgical treatment for a midtibial stress fracture. © 2016 The Author(s).

  10. Biomechanical evaluation of an integrated fixation cage during fatigue loading: a human cadaver study.

    PubMed

    Palepu, Vivek; Peck, Jonathan H; Simon, David D; Helgeson, Melvin D; Nagaraja, Srinidhi

    2017-04-01

    OBJECTIVE Lumbar cages with integrated fixation screws offer a low-profile alternative to a standard cage with anterior supplemental fixation. However, the mechanical stability of integrated fixation cages (IFCs) compared with a cage with anterior plate fixation under fatigue loading has not been investigated. The purpose of this study was to compare the biomechanical stability of a screw-based IFC with a standard cage coupled with that of an anterior plate under fatigue loading. METHODS Eighteen functional spinal units were implanted with either a 4-screw IFC or an anterior plate and cage (AP+C) without integrated fixation. Flexibility testing was conducted in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) on intact spines, immediately after device implantation, and post-fatigue up to 20,000 cycles of FE loading. Stability parameters such as range of motion (ROM) and lax zone (LZ) for each loading mode were compared between the 2 constructs at multiple stages of testing. In addition, construct loosening was quantified by subtracting post-instrumentation ROM from post-fatigue ROM. RESULTS IFC and AP+C configurations exhibited similar stability (ROM and LZ) at every stage of testing in FE (p ≥ 0.33) and LB (p ≥ 0.23) motions. In AR, however, IFCs had decreased ROM compared with AP+C constructs at pre-fatigue (p = 0.07) and at all post-fatigue time points (p ≤ 0.05). LZ followed a trend similar to that of ROM in AR. ROM increased toward intact motion during fatigue cycling for AP+C and IFC implants. IFC specimens remained significantly (p < 0.01) more rigid than specimens in the intact condition during fatigue for each loading mode, whereas AP+C construct motion did not differ significantly (p ≥ 0.37) in FE and LB and was significantly greater (p < 0.01) in AR motion compared with intact specimens after fatigue. Weak to moderate correlations (R 2 ≤ 56%) were observed between T-scores and construct loosening, with lower T-scores leading to decreased stability after fatigue testing. CONCLUSIONS These data indicate that a 4-screw IFC design provides fixation similar to that provided by an AP+C construct in FE and LB during fatigue testing and better stability in AR motion.

  11. Determination of muscle effort at the proximal femur rotation osteotomy

    NASA Astrophysics Data System (ADS)

    Sachenkov, O.; Hasanov, R.; Andreev, P.; Konoplev, Yu

    2016-11-01

    The paper formulates the problem of biomechanics of a new method for treatment of Legg-Calve-Perthes disease. Numerical calculations of the rotational flexion osteotomy have been carried out for a constructed mathematical model of the hip joint, taking into account the main set of muscles. The work presents the results of the calculations and their analysis. The results have been compared with the clinical data. The calculations of the reactive forces arising in the acetabulum and the proximal part of the femur allowed us to reveal that this reactive force changes both in value and direction. These data may be useful for assessing the stiffness of an external fixation device used in orthopedic intervention and for evaluating the compression in the joint.

  12. A biomechanical analysis of the self-retaining pedicle hook device in posterior spinal fixation

    PubMed Central

    van Laar, Wilbert; Meester, Rinse J.; Smit, Theo H.

    2007-01-01

    Regular hooks lack initial fixation to the spine during spinal deformity surgery. This runs the risk of posterior hook dislodgement during manipulation and correction of the spinal deformity, that may lead to loss of correction, hook migration, and post-operative junctional kyphosis. To prevent hook dislodgement during surgery, a self-retaining pedicle hook device (SPHD) is available that is made up of two counter-positioned hooks forming a monoblock posterior claw device. The initial segmental posterior fixation strength of a SPHD, however, is unknown. A biomechanical pull-out study of posterior segmental spinal fixation in a cadaver vertebral model was designed to investigate the axial pull-out strength for a SPHD, and compared to the pull-out strength of a pedicle screw. Ten porcine lumbar vertebral bodies were instrumented in pairs with two different instrumentation constructs after measuring the bone mineral density of each individual vertebra. The instrumentation constructs were extracted employing a material testing system using axial forces. The maximum pull-out forces were recorded at the time of the construct failure. Failure of the SPHD appeared in rotation and lateral displacement, without fracturing of the posterior structures. The average pull-out strength of the SPHD was 236 N versus 1,047 N in the pedicle screws (P < 0.001). The pull-out strength of the pedicle screws showed greater correlation with the BMC compared to the SPHD (P < 0.005). The SPHD showed to provide a significant inferior segmental fixation to the posterior spine in comparison to pedicle screw fixation. Despite the beneficial characteristics of the monoblock claw construct in a SPHD, that decreases the risk of posterior hook dislodgement during surgery compared to regular hooks, the SPHD does not improve the pull-out strength in such a way that it may provide a biomechanically solid alternative to pedicle screw fixation in the posterior spine. PMID:17203270

  13. Hybrid fixation with sublaminar polyester bands in the treatment of neuromuscular scoliosis: a comparative analysis.

    PubMed

    Albert, Michael C; LaFleur, Brett C

    2015-03-01

    Segmental spinal instrumentation with Luque wire fixation has been the standard treatment of neuromuscular scoliosis for >30 years. More recently, pedicle screw constructs have become the most widely utilized method of posterior spinal fixation; however, they are associated with complications such as implant malposition. We report the use of polyester bands and clamps utilized with pedicle screws in a hybrid fixation construct in the treatment of neuromuscular scoliosis. A retrospective review was conducted of 115 pediatric spinal deformity cases between 2008 and 2010 at a single center performed by a single surgeon. Intraoperative and postoperative complications were recorded. Radiographs were reviewed preoperatively and at the latest follow-up. A systematic review of the literature was conducted. Data from case series reporting outcomes of sublaminar wires and all-pedicle screw constructs in the treatment of neuromuscular scoliosis were compared with outcomes of the present study. Twenty-nine patients with neuromuscular scoliosis who underwent segmental spinal instrumentation with a hybrid construct including sublaminar bands and pedicle screws were included. There was an average follow-up of 29 months (range, 12 to 40 mo). The average postoperative correction of coronal balance was 69% (range, 24 to 71 degrees). Sagittal balance was corrected to within 2 cm of the C7 plumbline in 97% of patients. The loss of coronal and sagittal correction at latest follow-up was 0% and 2%, respectively. There were 2 intraoperative clamp failures of the 398 implants (0.5%). There were 2 major (6.9%) and 7 minor (24%) complications in 7 patients (24% overall). These results compared favorably to previous case series of sublaminar wire and all-pedicle screw fixation techniques. The polyester band technique is an excellent adjunct in the correction of spinal deformity in patients with neuromuscular scoliosis. Sublaminar bands utilized in a hybrid construct appear to be safe, can achieve corrections equivalent to all-pedicle screw constructs, and may decrease the potential complications associated with every level transpedicular fixation in the patient with a highly dysmorphic and osteoporotic spine. Level IV: cohort study.

  14. Proximal femoral resection and articulated hip distraction with an external fixator for the treatment of painful spastic hip dislocations in pediatric patients with spastic quadriplegia.

    PubMed

    Lampropulos, Mario; Puigdevall, Miguel H; Zapozko, Daniel; Malvárez, Héctor R

    2008-01-01

    We describe the results obtained with an alternative method of treatment for spastic painful hip dislocations in nonambulatory patients, which consists of a proximal femoral resection with capsular interposition arthroplasty, and the addition of a hinged external fixator for postoperative articulated hip distraction to allow for an immediate upright position and the ability to sit in a wheelchair. We performed this technique in three patients (four hips) with a mean age at the time of surgery of 15 years. Postoperatively, clinical improvement was observed in all four hips, with respect to pain relief, sitting tolerance, perineal care and functional range of motion.

  15. Suture Button Fixation Versus Syndesmotic Screws in Supination-External Rotation Type 4 Injuries: A Cost-Effectiveness Analysis.

    PubMed

    Neary, Kaitlin C; Mormino, Matthew A; Wang, Hongmei

    2017-01-01

    In stress-positive, unstable supination-external rotation type 4 (SER IV) ankle fractures, implant selection for syndesmotic fixation is a debated topic. Among the available syndesmotic fixation methods, the metallic screw and the suture button have been routinely compared in the literature. In addition to strength of fixation and ability to anatomically restore the syndesmosis, costs associated with implant use have recently been called into question. This study aimed to examine the cost-effectiveness of the suture button and determine whether suture button fixation is more cost-effective than two 3.5-mm syndesmotic screws not removed on a routine postoperative basis. Economic and decision analysis; Level of evidence, 2. Studies with the highest evidence levels in the available literature were used to estimate the hardware removal and failure rates for syndesmotic screws and suture button fixation. Costs were determined by examining the average costs for patients who underwent surgery for unstable SER IV ankle fractures at a single level-1 trauma institution. A decision analysis model that allowed comparison of the 2 fixation methods was developed. Using a 20% screw hardware removal rate and a 4% suture button hardware removal rate, the total cost for 2 syndesmotic screws was US$20,836 and the total effectiveness was 5.846. This yielded a total cost of $3564 per quality-adjusted life-year (QALY) over an 8-year time period. The total cost for suture button fixation was $19,354 and the total effectiveness was 5.904, resulting in a total cost of $3294 per QALY over the same time period. A sensitivity analysis was then conducted to assess suture button fixation costs as well as screw and suture button hardware removal rates. Other possible treatment scenarios were also examined, including 1 screw and 2 suture buttons for operative fixation of the syndesmosis. To become more cost-effective, the screw hardware removal rate would have to be reduced to less than 10%. Furthermore, fixation with a single suture button continued to be the dominant treatment strategy compared with 2 suture buttons, 1 screw, and 2 screws for syndesmotic fixation. This cost-effectiveness analysis suggests that for unstable SER IV ankle fractures, suture button fixation is more cost-effective than syndesmotic screws not removed on a routine basis. Suture button fixation was a dominant treatment strategy, because patients spent on average $1482 less and had a higher quality of life by 0.058 QALYs compared with patients who received fixation with 2 syndesmotic screws. Assuming that functional outcomes and failure rates were equivalent, screw fixation only became more cost-effective when the screw hardware removal rate was reduced to less than 10% or when the suture button cost exceeded $2000. In addition, fixation with a single suture button device proved more cost-effective than fixation with either 1 or 2 syndesmotic screws.

  16. Management of maxillofacial injuries in Iraq.

    PubMed

    Kummoona, Raja

    2011-09-01

    These clinical studies reflect the experience of the author in managing 673 patients treated during the last 8 years. All patients were treated in the Maxillofacial Unit, Surgical Specialties Hospital, Medical City, Baghdad, and in the author's private clinic. Included patients were 530 males and 143 females; patients' age ranged between 1 year and 75 years (mean, 38 y). Distribution of injuries was as follows: fracture of the mandible, 287 (42.64%); middle third injuries, 39 (5.79%); orbital injuries, 236 (35.07%; including 12 cases with cranioorbital injuries); injuries in children, 27 (4.0%); fracture of the zygoma, 52 (7.73%); and fracture of the nose, 40 (5.94%).Maxillofacial injuries in this study were classified as follows: (1) craniomaxillofacial with head injuries and cerebrospinal fluid leak; (2) fracture of the middle third including Le Fort I, II, and III and midline split in the face; (3) fracture of the mandible as an isolated injury or as part of a facial skeleton injury; and (4) isolated complex injuries of the zygoma, the orbital skeleton, and the nasoethmoidal region.The technique used for treating middle third injuries was external fixation either by halo frame (with vertical rods and cheek wires) or by box frame (using 4 external pins connected by rods) or internal fixation by suspending the middle third with internal wires (0.5 mm stainless steel) from the zygomatic process of the frontal bone beneath the zygomatic arch down the lower arch bar. Fractures of the mandible were treated by gunning splint with intermaxillary fixation (IMF) or with open reduction and fixation by stainless steel wire with IMF or by IMF screw or by an arch bar and IMF. Other fractures such as fracture of the orbit were treated by bone graft, sialastic, or lyophilized dura with open reduction. Fractures of the zygoma were treated by open reduction and fixation with stainless steel wire and bone graft or by reduction without fixation. Fractures of the nose were treated by reduction with straightening of the septum with a splint (lead splint or polythene) or by external splint with plaster of Paris. With the techniques used, results from managing these cases were satisfactory.

  17. Early results of a simple distraction dynamic external fixator in management of comminuted intra-articular fractures of base of middle phalanx.

    PubMed

    Mansha, Muhammad; Miranda, Sanjay

    2013-12-01

    Treatment for comminuted fracture dislocations of the proximal interphalangeal joint (pilon injuries) remains a challenge. We present our short term results of twelve pilon fracture dislocations treated by closed reduction and application of a distraction dynamic external fixator. The aim of the study was to assess the clinical outcomes and compare them to the original description by Hynes and Giddins. A cohort of 12 consecutive patients with pilon fracture of the proximal interphalangeal joint (comminuted fracture of the base of middle phalanx, longitudinally unstable with joint subluxation), were treated with this method over the study period. Data was collected by an independent observer at last follow-up appointment in the clinic. The outcome measures recorded were; level of residual pain, arc of motion, X-ray appearance, return to work and satisfaction with the procedure. The study group comprises of 7 male and 5 female patients at a mean age of 38.1 years (range 21-70 years). The average range of movement achieved was 13-87° at a mean follow-up of 16.4 weeks (Range 12-42 weeks). Early return to work, good pain relief and high level of patient satisfaction were achieved. No serious complication was noted during this period. We used the construct with slight modification of the original description and we feel this modification may help to reduce the pin site infection. We found the results reproducible and based on our experience we recommend this technique to treat these complex intra-articular fractures of base of middle phalanx.

  18. An in Vivo Experimental Comparison of Stainless Steel and Titanium Schanz Screws for External Fixation.

    PubMed

    Ganser, Antonia; Thompson, Rosemary E; Tami, Ivan; Neuhoff, Dirk; Steiner, Adrian; Ito, Keita

    2007-02-01

    To compare the clinical benefits of stainless steel (SS) to titanium (Ti) on reducing pin track irritation/infection and pin loosening during external fracture fixation. A tibial gap osteotomy was created in 17 sheep and stabilized with four Schanz screws of either SS or Ti and an external fixation frame. Over the 12 week observation period, pin loosening was assessed by grading the radiolucency around the pins and measuring the extraction torque on pin removal at sacrifice. Irritation/infection was assessed with weekly clinical pin track grading. A histological analysis of the tissue adjacent to the pin site was made to assess biocompatibility. A statistically non-significant trend for less bone resorption around Ti pins was found during the early observation period. However, at sacrifice, there was no difference between the two materials. Also, there was no difference in the extraction torque, and there was similar remodeling and apposition of the bone around the pins. A statistically non-significant trend for more infection about SS pins at sacrifice was found. Histology showed a slightly higher prevalence of reactionary cells in SS samples, but was otherwise not much different than around Ti pins. There is no clinically relevant substantial advantage in using either SS or Ti pins on reducing pin loosening or pin track irritation/infection.

  19. Prevention of pin tract infection in external stainless steel fixator frames using electric current in a goat model.

    PubMed

    van der Borden, Arnout J; Maathuis, Patrick G M; Engels, Eefje; Rakhorst, Gerhard; van der Mei, Henny C; Busscher, Henk J; Sharma, Prashant Kumar

    2007-04-01

    Pin tract infections of external fixators used in orthopaedic reconstructive bone surgery are serious complications that can eventually lead to periostitis and osteomyelitis. In vitro experiments have demonstrated that bacteria adhering to stainless steel in a biofilm mode of growth detach under the influence of small electric currents, while remaining bacteria become less viable upon current application. Therefore, we have investigated whether a 100microA electric current can prevent signs of clinical infection around percutaneous pins, implanted in the tibia of goats. Three pins were inserted into the lateral right tibia of nine goats, of which one served for additional frame support. Two pins were infected with a Staphylococcus epidermidis strain of which one pin was subjected to electric current, while the other pin was used as control. Pin sites were examined daily. The wound electrical resistance decreased with worsening of the infection from a dry condition to a purulent stage. After 21 days, animals were sacrificed and the pins taken out. Infection developed in 89% of the control pin sites, whereas only 11% of the pin sites in the current group showed infection. These results show that infection of percutaneous pin sites of external fixators in reconstructive bone surgery can be prevented by the application of a small DC electric current.

  20. Symphyseal internal rod fixation versus standard plate fixation for open book pelvic ring injuries: a biomechanical study.

    PubMed

    Osterhoff, G; Tiziani, S; Hafner, C; Ferguson, S J; Simmen, H-P; Werner, C M L

    2016-04-01

    This study investigates the biomechanical stability of a novel technique for symphyseal internal rod fixation (SYMFIX) using a multiaxial spinal screw-rod implant that allows for direct reduction and can be performed percutaneously and compares it to standard internal plate fixation of the symphysis. Standard plate fixation (PLATE, n = 6) and the SYMFIX (n = 6) were tested on pelvic composite models with a simulated open book injury using a universal testing machine. On a previously described testing setup, 500 consecutive cyclic loadings were applied with sinusoidal resulting forces of 200 N. Displacement under loading was measured using an optoelectronic camera system and construct rigidity was calculated as a function of load and displacement. The rigidity of the PLATE construct was 122.8 N/mm (95 % CI: 110.7-134.8), rigidity of the SYMFIX construct 119.3 N/mm (95 % CI: 105.8-132.7). Displacement in the symphyseal area was mean 0.007 mm (95 % CI: 0.003-0.012) in the PLATE group and 0.021 mm (95 % CI: 0.011-0.031) in the SYMFIX group. Displacement in the sacroiliac joint area was mean 0.156 mm (95 % CI: 0.051-0.261) in the PLATE group and 0.120 mm (95 % CI: 0.039-0.201) in the SYMFIX group. In comparison to standard internal plate fixation for the stabilization of open book pelvic ring injuries, symphyseal internal rod fixation using a multiaxial spinal screw-rod implant in vitro shows a similar rigidity and comparable low degrees of displacement.

  1. Proceedings : Direct Fixation Fastener Workshop

    DOT National Transportation Integrated Search

    1985-06-01

    This report is a collection of papers and discussion transcripts from a workshop on direct fixation fastener systems (DFFS) that are increasingly being used in the construction of modern rail transit systems and system extensions. Preservice testing,...

  2. An alternative graft fixation technique for scaphoid nonunions treated with vascular bone grafting.

    PubMed

    Korompilias, Anastasios V; Lykissas, Marios G; Kostas-Agnantis, Ioannis P; Gkiatas, Ioannis; Beris, Alexandros E

    2014-07-01

    To present our experience with vascularized bone grafting based on the 1,2-intercompartmental supraretinacular artery for the management of established scaphoid nonunion and to investigate the efficacy of graft immobilization with a combination of Kirschner wires and transarticular external fixation. A retrospective chart and radiographic review was conducted for patients with the diagnosis of scaphoid nonunion of the proximal pole or the waist treated with the 1,2-intercompartmental supraretinacular artery-based vascularized graft and fixed with a combination of Kirschner wires and transarticular external fixation between 2007 and 2011. We observed 23 consecutive patients for a mean of 34 ± 4 months. All patients were males with mean age of 25 ± 5 years. All patients had scaphoid nonunion and associated humpback deformity. The mean duration of nonunion was 7 ± 1 months. All scaphoid nonunions united after the index procedure at a mean of 10 ± 1 weeks. Two patients had avascular necrosis of the proximal pole based on the preoperative magnetic resonance imaging findings. After surgery, deformity correction was achieved in all patients, as recorded by the decrease in the lateral intrascaphoid angle and the increase in the dorsal scaphoid angle. At the last follow-up, no patients reported wrist pain. The mean Disabilities of the Arm, Shoulder, and Hand score improved significantly from 32 ± 12 before the operation to 5 ± 3 at the last postoperative visit. All patients showed statistically significant improvement in the range of motion and the grip strength of the involved wrist. The results of this study support the combined use of Kirschner wires and transarticular external fixation for fixation of a 1,2-intercompartmental supraretinacular artery-based vascular bone graft in the treatment of scaphoid nonunions. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Reverse Dynamization: Influence of Fixator Stiffness on the Mode and Efficiency of Large-Bone-Defect Healing at Different Doses of rhBMP-2.

    PubMed

    Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher

    2016-04-20

    Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  4. Use of a Multivector Mandibular Distractor for Treatment of Pediatric Proximal Interphalangeal Joint Pilon Fractures: A Case-Based Review.

    PubMed

    Pedreira, Rachel; Cho, Brian H; Geer, Angela; DeJesus, Ramon A

    2018-04-01

    The difficulties in surgical treatment of pilon fractures of the finger include fragment reconstitution and posthealing stiffness. In adults, external fixation with traction and early active range of motion (AROM)/passive range of motion (PROM) during healing is considered necessary for avoiding joint stiffness and attaining realignment. The authors present a unique approach to pediatric pilon fractures that uses open reduction and multivector external fixation with delayed AROM/PROM. Initial immobilization and significant traction allowed for joint realignment and prevented noncompliance with staged distraction. The authors believe this immobilization leads to a superior outcome because, unlike adults, children tend to avoid stiffness and a larger distraction force allowed for sufficient joint realignment to regain range of motion (ROM). A right-handed 13-year-old boy sustained a right ring finger fracture and presented 12 days later. Radiographs revealed a comminuted Salter-Harris 4 fracture of the middle phalanx. The patient underwent open reduction and placement of multivector external fixation using a pediatric mandibular distractor/fixator. Significant traction was applied to distract the finger to length. Hardware was removed 6 weeks postoperatively and AROM was initiated after splinting. The patient started PROM 8 weeks postoperatively. Strengthening was initiated 2 weeks later. ROM improved and rehabilitation was continued. The patient exhibited nearly equal grip strength 12 weeks postoperatively. At 14 months follow-up, radiographs showed complete healing and joint realignment. There was no deformity or pain and finger length was restored. Management of pediatric pilon fractures is rarely described and presents unique considerations. Early-stage traction and immobilization using a multivector mandibular fixator/distractor is suitable in a child because noncompliance is avoided and there is a decreased risk for stiffness. Combining early immobilization with subsequent-staged AROM, PROM, and strengthening resulted in no loss of ROM and maintained articular symmetry.

  5. Improving tribological and anti-bacterial properties of titanium external fixation pins through surface ceramic conversion.

    PubMed

    Dong, Huan; Mukinay, Tatiana; Li, Maojun; Hood, Richard; Soo, Sein Leung; Cockshott, Simon; Sammons, Rachel; Li, Xiaoying

    2017-01-01

    In this study, an advanced ceramic conversion surface engineering technology has been applied for the first time to self-drilling Ti6Al4V external fixation pins to improve their performance in terms of biomechanical, bio-tribological and antibacterial properties. Systematic characterisation of the ceramic conversion treated Ti pins was carried out using Scanning electron microscope, X-ray diffraction, Glow-discharge optical emission spectroscopy, nano- and micro-indentation and scratching; the biomechanical and bio-tribological properties of the surface engineered Ti pins were evaluated by insertion into high density bone simulation material; and the antibacterial behaviour was assessed with Staphylococcus aureus NCTC 6571. The experimental results have demonstrated that the surfaces of Ti6Al4V external fixation pins were successfully converted into a TiO 2 rutile layer (~2 μm in thickness) supported by an oxygen hardened case (~15 μm in thickness) with very good bonding due to the in-situ conversion nature. The maximum insertion force and temperature were reduced from 192N and 31.2 °C when using the untreated pins to 182N and 26.1 °C when the ceramic conversion treated pins were tested. This is mainly due to the significantly increased hardness (more than three times) and the effectively enhanced wear resistance of the cutting edge of the self-drilling Ti pins following the ceramic conversion treatment. The antibacterial tests also revealed that there was a significantly reduced number of bacteria isolated from the ceramic conversion treated pins compared to the untreated pins of around 50 % after 20 h incubation, P < 0.01 (0.0024). The results reported are encouraging and could pave the way towards high-performance anti-bacterial titanium external fixation pins with reduced pin-track infection and pin loosing.

  6. The effect of laparotomy and external fixator stabilization on pelvic volume in an unstable pelvic injury.

    PubMed

    Ghanayem, A J; Wilber, J H; Lieberman, J M; Motta, A O

    1995-03-01

    Determine if laparotomy further destabilizes an unstable pelvic injury and increases pelvic volume, and if reduction and stabilization restores pelvic volume and prevents volume changes secondary to laparotomy. Cadaveric pelvic fracture model. Unilateral open-book pelvic ring injuries were created in five fresh cadaveric specimens by directly disrupting the pubic symphysis, left sacroliac joint, and sacrospinous and sacrotuberous ligaments. Pelvic volume was determined using computerized axial tomography for the intact pelvis, disrupted pelvis with both a laparotomy incision opened and closed, and disrupted pelvis stabilized and reduced using an external fixator with the laparotomy incision opened. The average volume increase in the entire pelvis (from the top of the iliac crests to the bottom of the ischial tuberosities) between a nonstabilized injury with the abdomen closed and then subsequently opened was 15 +/- 5% (423 cc). The average increase in entire pelvic volume between a stabilized and reduced pelvis and nonstabilized pelvis, both with the abdomen open, was 26 +/- 5% (692 cc). The public diastasis increased from 3.9 to 9.3 cm in a nonstabilized pelvis with the abdomen closed and then subsequently opened. Application of a single-pin anterior-frame external fixator reduced the pubic diastasis anatomically and reduced the average entire and true (from the pelvic brim to the ischeal tuberosities) pelvic volumes to within 3 +/- 4 and 8 +/- 6% of the initial volume, respectively. We believe that the abdominal wall provides stability to an unstable pelvic ring injury via a tension band effect on the iliac wings. Our results demonstrate that a laparotomy further destabilized an open-book pelvic injury and subsequently increased pelvic volume and pubic diastasis. This could potentially increase blood loss from the pelvic injury and delay the tamponade effect of reduction and stabilization. A single-pin external fixator prevents the destabilizing effect of the laparotomy and effectively reduces pelvic volume. These data support reduction and temporary stabilization of unstable pelvic injuries before or concomitantly with laparotomy.

  7. Initial Experience of US Marine Corps Forward Resuscitative Surgical System during Operation Iraqi Freedom

    DTIC Science & Technology

    2005-01-01

    lavage, and splinting. Exter- nal fixation was used when there was concurrent vascular pro- cedures or if fractures were extremely unstable...foot open fracture Completion lower extremity amputation; completion right upper amputation; external fixation right ankle 8/Iraqi child Class 3 shock...infection Comminuted mandible fracture with loss of airway (casualty 1 in Table 2) Airway control Infection of mandibular plate at echelon 5 facility

  8. SPIRE spinous process stabilization plate: biomechanical evaluation of a novel technology. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005.

    PubMed

    Wang, Jeremy C; Spenciner, David; Robinson, James C

    2006-02-01

    The authors studied the biomechanical properties of a novel spinous process stabilization plate (CD HORIZON SPIRE Spinal System) and present the results in comparison with those of other posterior fixation methods. Ten functional cadaveric lumbar segments were subjected to nondestructive quasistatic loading forces in 10 different conditions: intact, destabilized (discectomy), fitted with spinous process plate (SPP) alone, with anterior-column support (ACS) alone, ACS with SPP, ACS with posterior translaminar facet screw (PTFS) fixation, ACS with unilateral pedicle screw and rod (UPSR) fixation, ACS with bilateral pedicle screw and rod (BPSR) fixation, UPSR alone, or BPSR alone. Stiffness and range of motion (ROM) data were compared using a repeated-measures, one-way analysis of variance. The construct with greatest mean limitation of flexion-extension ROM was ACS/SPP at 4.14 degrees whereas it was 5.75 degrees for ACS/UPSR fixation, 5.03 degrees for ACS/BPSR fixation, and 10.13 degrees for the intact spine. The SPIRE plate alone also provided greater flexion and extension stiffness, with less ROM than other posterior stabilization options. Fixation with BPSR with or without ACS resulted in the stiffest construct in lateral bending and axial rotation. The SPP and UPSR fixation groups were equivalent in resisting lateral bending and axial rotation forces with or without ACS. The SPIRE plate effectively stabilized the spine, and the test results compare favorably with other fixation techniques that are more time consuming to perform and have greater inherent risks.

  9. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion.

    PubMed

    Sod, Gary A; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S; Gill, Marjorie S

    2007-12-01

    To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws (DCP-TLS) inserted in lag fashion for equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=18 pairs). For each forelimb pair, 1 PIP joint was stabilized with an ESP (8 hole, 4.5 mm) and 1 with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression with load applied under displacement control at a constant rate of 5 cm/s. Six construct pairs were tested for cyclic fatigue under axial compression with cyclic load (0-7.5 kN) applied at 6 Hz; cycles to failure were recorded. Six construct pairs were tested in single cycle to failure under torsional loading applied at a constant displacement rate (0.17 radians/s) until rotation of 0.87 radians occurred. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load for ESP fixation were significantly greater (for axial compression and torsion) than for DCP-TLS fixation. Mean (+/- SD) values for the ESP and DCP-TLS fixation techniques, respectively, in single cycle to failure under axial compression were: yield load 123.9 +/- 8.96 and 28.5 +/- 3.32 kN; stiffness, 13.11 +/- 0.242 and 2.60 +/- 0.17 kN/cm; and failure load, 144.4 +/- 13.6 and 31.4 +/- 3.8 kN. In single cycle to failure under torsion, mean (+/- SD) values for ESP and DCP-TLS, respectively, were: stiffness 2,022 +/- 26.2 and 107.9 +/- 11.1 N m/rad; and failure load: 256.4 +/- 39.2 and 87.1 +/- 11.5 N m. Mean cycles to failure in axial compression of ESP fixation (622,529 +/- 65,468) was significantly greater than DCP-TLS (95,418 +/- 11,037). ESP was superior to an axial 3-hole narrow DCP with 2 abaxial transarticular screws inserted in lag fashion in resisting static overload forces and cyclic fatigue. In vitro results support further evaluation of ESP for PIP joint arthrodesis in horses. Its specific design may provide increased stability without need for external coaptation support.

  10. Strength of fixation constructs for basilar osteotomies of the first metatarsal.

    PubMed

    Lian, G J; Markolf, K; Cracchiolo, A

    1992-01-01

    Twenty-four pairs of fresh-frozen human feet had a proximal osteotomy of the first metatarsal that was fixed using either screws, staples, or K wires. Each metatarsal was excised and the specimen was loaded to failure in a cantilever beam configuration by applying a superiorly directed force to the metatarsal head using an MTS servohydraulic test machine. Specimens with a crescentic osteotomy that were fixed using a single screw demonstrated higher mean failure moments than pairs that were fixed with four staples or two K wires; staples were the weakest construct. All specimens fixed with staples failed by bending of the staples without bony fracture; all K wire constructs but one failed by wire bending. Chevron and crescentic osteotomies fixed with a single screw demonstrated equal bending strengths; the bending strength of an oblique osteotomy fixed with two screws was 82% greater than for a crescentic osteotomy fixed with a single screw. Basilar osteotomies of the first metatarsal are useful in correcting metatarsus primus varus often associated with hallux valgus pathology. Fixation strength is an important consideration since weightbearing forces on the head of the first metatarsal acting at a distance from the osteotomy site subject the construct to a dorsiflexion bending moment, as simulated in our tests. Our results show that screw fixation is the strongest method for stabilizing a basilar osteotomy. Based upon the relatively low bending strengths of the staple and K wire constructs, we would not recommend these forms of fixation.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study.

    PubMed

    Kosmopoulos, Victor; Luedke, Colten; Nana, Arvind D

    2015-01-01

    A smaller humerus in some patients makes the use of a large fragment fixation plate difficult. Dual small fragment plate constructs have been suggested as an alternative. This study compares the biomechanical performance of three single and one dual plate construct for mid-diaphyseal humeral fracture fixation. Five humeral shaft finite element models (1 intact and 4 fixation) were loaded in torsion, compression, posterior-anterior (PA) bending, and lateral-medial (LM) bending. A comminuted fracture was simulated by a 1-cm gap. Fracture fixation was modelled by: (A) 4.5-mm 9-hole large fragment plate (wide), (B) 4.5-mm 9-hole large fragment plate (narrow), (C) 3.5-mm 9-hole small fragment plate, and (D) one 3.5-mm 9-hole small fragment plate and one 3.5-mm 7-hole small fragment plate. Model A showed the best outcomes in torsion and PA bending, whereas Model D outperformed the others in compression and LM bending. Stress concentrations were located near and around the unused screw holes for each of the single plate models and at the neck of the screws just below the plates for all the models studied. Other than in PA bending, Model D showed the best overall screw-to-screw load sharing characteristics. The results support using a dual small fragment locking plate construct as an alternative in cases where crutch weight-bearing (compression) tolerance may be important and where anatomy limits the size of the humerus bone segment available for large fragment plate fixation.

  12. SURGICAL OUTCOME OF SIMULTANEOUS INTRAOCULAR LENS RESCUE AND SUTURELESS INTRASCLERAL TUNNEL FIXATION OF DISLOCATED INTRAOCULAR LENSES.

    PubMed

    Kim, Min; Lee, Dong H; Koh, Hyoung J; Lee, Sung C; Kim, Sung S

    2015-07-01

    To report short-term surgical outcomes of single-stage simultaneous rescue and sutureless intrascleral fixation of dislocated intraocular lens (IOLs). Sixteen eyes of 16 patients who underwent simultaneous rescue and intrascleral fixation of dislocated 3-piece IOLs were retrospectively evaluated. Partial thickness limbal-based scleral flaps (2.0 × 2.0 mm) were created, and a 22-gauge round needle was used to create a sclerotomy at 1.5 mm from the limbus under the previously created scleral flap, and a 23-gauge trans pars plana vitrectomy was performed. Bimanual maneuvers using two 23-gauge end-grasping forceps under chandelier illumination and a wide-angle viewing system enabled 1 step rescue of IOLs from the posterior vitreous cavity with 1 hand and simultaneous haptic externalization through sclerotomy with the other hand. An externalized haptic was placed into the 3-mm intrascleral tunnel created using a bent 26-gauge needle. Fibrin glue was used to fixate haptics and close the scleral flaps. Intraocular lenses were successfully rescued and sclera-fixated through intrascleral tunnels in all 16 eyes (mean age, 56.56 ± 19.89 years). The mean preoperative logarithm of the minimum angle of resolution best-corrected visual acuity was 0.92 ± 0.68, and this significantly improved at 6 months to 0.289 ± 0.36 (P = 0.003). During the follow-up period (10.1 ± 3.21 months), no significant change of endothelial cell count or central foveal thickness was noted postoperatively (P = 0.203 and P = 0.979, respectively). There were no significant postoperative complications such as IOL dislocation, IOL decentration, retinal detachment, endophthalmitis, or postoperative hypotony. Simultaneous rescue and sutureless intrascleral haptic fixation of dislocated 3-piece IOLs using bimanual maneuvers is an effective, safe, and minimally invasive surgical method to rescue and fixate the dislocated IOL without further explant.

  13. Which Surgical Treatment for Open Tibial Shaft Fractures Results in the Fewest Reoperations? A Network Meta-analysis.

    PubMed

    Foote, Clary J; Guyatt, Gordon H; Vignesh, K Nithin; Mundi, Raman; Chaudhry, Harman; Heels-Ansdell, Diane; Thabane, Lehana; Tornetta, Paul; Bhandari, Mohit

    2015-07-01

    Open tibial shaft fractures are one of the most devastating orthopaedic injuries. Surgical treatment options include reamed or unreamed nailing, plating, Ender nails, Ilizarov fixation, and external fixation. Using a network meta-analysis allows comparison and facilitates pooling of a diverse population of randomized trials across these approaches in ways that a traditional meta-analysis does not. Our aim was to perform a network meta-analysis using evidence from randomized trials on the relative effect of alternative approaches on the risk of unplanned reoperation after open fractures of the tibial diaphysis. Our secondary study endpoints included malunion, deep infection, and superficial infection. A network meta-analysis allows for simultaneous consideration of the relative effectiveness of multiple treatment alternatives. To do this on the subject of surgical treatments for open tibial fractures, we began with systematic searches of databases (including EMBASE and MEDLINE) and performed hand searches of orthopaedic journals, bibliographies, abstracts from orthopaedic conferences, and orthopaedic textbooks, for all relevant material published between 1980 and 2013. Two authors independently screened abstracts and manuscripts and extracted the data, three evaluated the risk of bias in individual studies, and two applied Grading of Recommendation Assessment, Development and Evaluation (GRADE) criteria to bodies of evidence. We included all randomized and quasirandomized trials comparing two (or more) surgical treatment options for open tibial shaft fractures in predominantly (ie, > 80%) adult patients. We calculated pooled estimates for all direct comparisons and conducted a network meta-analysis combining direct and indirect evidence for all 15 comparisons between six stabilization strategies. Fourteen trials published between 1989 and November 2011 met our inclusion criteria; the trials comprised a total of 1279 patients surgically treated for open tibial shaft fractures. Moderate confidence evidence showed that unreamed nailing may reduce the likelihood of reoperation compared with external fixation (network odds ratio [OR], 0.38; 95% CI, 0.23-0.62; p < 0.05), although not necessarily compared with reamed nailing (direct OR, 0.74; 95% CI, 0.45-1.24; p = 0.25). Only low- or very low-quality evidence informed the primary outcome for other treatment comparisons, such as those involving internal plate fixation, Ilizarov external fixation, and Ender nailing. Method ranking based on reoperation data showed that unreamed nailing had the highest probability of being the best treatment, followed by reamed nailing, external fixation, and plate fixation. CIs around pooled estimates of malunion and infection risk were very wide, and therefore no conclusive results could be made based on these data. Current evidence suggests that intramedullary nailing may be superior to other fixation strategies for open tibial shaft fractures. Use of unreamed nails over reamed nails also may be advantageous in the setting of open fractures, but this remains to be confirmed. Unfortunately, these conclusions are based on trials that have had high risk of bias and poor precision. Larger and higher-quality head-to-head randomized controlled trials are required to confirm these conclusions and better inform clinical decision-making. Level I, therapeutic study.

  14. Pelvic ring injuries: Surgical management and long-term outcomes

    PubMed Central

    Halawi, Mohamad J.

    2016-01-01

    Pelvic ring injuries present a therapeutic challenge to the orthopedic surgeon. Management is based on the patient's physiological status, fracture classification, and associated injuries. Surgical stabilization is indicated in unstable injury patterns and those that fail nonsurgical management. The optimal timing for definitive fixation is not clearly defined, but early stabilization is recommended. Surgical techniques include external fixation, open reduction and internal fixation, and minimally invasive percutaneous osteosynthesis. Special considerations are required for concomitant acetabular fractures, sacral fractures, and those occurring in skeletally immature patients. Long-term outcomes are limited by lack of pelvis-specific outcome measures and burden of associated injuries. PMID:26908968

  15. Reverse Dynamization

    PubMed Central

    Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher

    2016-01-01

    Background: Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Methods: Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. Results: In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. Conclusions: These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Clinical Relevance: Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. PMID:27098327

  16. Biomechanical principles and mechanobiologic aspects of flexible and locked plating.

    PubMed

    Claes, Lutz

    2011-02-01

    The goal of minimally invasive surgery in extramedullary internal fixation has led to the development of flexible plates, bridging plates, and locked internal fixators. The change from conventional compression plates to these new implants, however, resulted in different biomechanics of fixation and different mechanobiologic processes for fracture healing. The aim of a flexible fixation is the stimulation of fracture healing by callus formation. Fracture healing follows mechanobiologic rules based mainly on interfragmentary strain, which is dependent on the stability of the fixation construct and the type of fracture. Knowledge of the mechanobiologic processes and the factors influencing the stability of fracture fixation are necessary for the surgeon to choose the correct technique for fracture fixation. Problems in the selection of the correct technique and limitations with the available implants as well as possible future developments are discussed.

  17. [TREATMENT OF PRONATION EXTERNAL ROTATION ANKLE FRACTURE COMBINED WITH SEPARATION OF DISTAL TIBIOFIBULAR SYNDESMOSIS].

    PubMed

    Wu, Benwen; Ding, Zhenqi; Huang, Guofeng; Liu, Guojun; Cai, Zhemin; Ding, Luobin; Li, Xiang

    2016-09-08

    To evaluate the difference between using and not using syndesmotic screw to treat pronation external rotation (PER) ankle fracture combined with separation of distal tibiofibular syndesmosis. Between April 2011 and October 2014, 46 cases of PER ankle fracture combined with separation of distal tibiofibular syndesmosis were treated, and syndesmotic screw was used in 24 cases (fixation group) and syndesmotic screw was not used in 22 cases (non-fixation group). There was no significant difference in gender, age, weight, cause of injury, side, injury to operation time, and fracture type between 2 groups ( P >0.05). The time for full weight-bearing, fracture healing time, and complications were recorded after operation. Anteroposterior and lateral X-ray films were taken to measure the tibiofibular overlap (TBOL) and tibiofibular clear space (TBCS). Baird-Jackson score was used to evaluate functional recovery of the ankle. All incision healed by first intention without complications. The cases were followed up 13-18 months (mean, 15.2 months) in 2 groups. The time for full weight-bearing was 8-12 weeks (median, 11 weeks) in fixation group, which was significantly later than that in non-fixation group (range, 6-10 weeks; median, 8 weeks) ( Z =-5.049, P =0.000). X-ray examination showed reduction of separation of distal tibiofibular syndesmosis. All fractures healed. The fracture healing time was (13.83±1.37) weeks in fixation group, and was (13.91±1.31) weeks in non-fixation group, showing no significant difference ( t =-0.191, P =0.945). No separation of distal tibiofibular syndesmosis, delayed union, nonunion, loosening, or breakage of fixation devices was observed in 2 groups. There was no significant difference in TBOL, TBCS, Baird-Jackson score and the excellent and good rate between 2 groups ( P >0.05). If the medial, lateral, and posterior structures of the ankle could be repaired according to injury, no significant influence on functional outcome of ankle or radiologic findings could be detected whether syndesmotic fixation is given or not in treating PER ankle fracture (exclude Maisonneuve fracture) combined with separation of distal tibiofibular syndesmosis.

  18. The role of external features in face recognition with central vision loss: A pilot study

    PubMed Central

    Bernard, Jean-Baptiste; Chung, Susana T.L.

    2016-01-01

    Purpose We evaluated how the performance for recognizing familiar face images depends on the internal (eyebrows, eyes, nose, mouth) and external face features (chin, outline of face, hairline) in individuals with central vision loss. Methods In Experiment 1, we measured eye movements for four observers with central vision loss to determine whether they fixated more often on the internal or the external features of face images while attempting to recognize the images. We then measured the accuracy for recognizing face images that contained only the internal, only the external, or both internal and external features (Experiment 2), and for hybrid images where the internal and external features came from two different source images (Experiment 3), for five observers with central vision loss and four age-matched control observers. Results When recognizing familiar face images, approximately 40% of the fixations of observers with central vision loss were centered on the external features of faces. The recognition accuracy was higher for images containing only external features (66.8±3.3% correct) than for images containing only internal features (35.8±15.0%), a finding contradicting that of control observers. For hybrid face images, observers with central vision loss responded more accurately to the external features (50.4±17.8%) than to the internal features (9.3±4.9%), while control observers did not show the same bias toward responding to the external features. Conclusions Contrary to people with normal vision who rely more on the internal features of face images for recognizing familiar faces, individuals with central vision loss show a higher dependence on using external features of face images. PMID:26829260

  19. The Role of External Features in Face Recognition with Central Vision Loss.

    PubMed

    Bernard, Jean-Baptiste; Chung, Susana T L

    2016-05-01

    We evaluated how the performance of recognizing familiar face images depends on the internal (eyebrows, eyes, nose, mouth) and external face features (chin, outline of face, hairline) in individuals with central vision loss. In experiment 1, we measured eye movements for four observers with central vision loss to determine whether they fixated more often on the internal or the external features of face images while attempting to recognize the images. We then measured the accuracy for recognizing face images that contained only the internal, only the external, or both internal and external features (experiment 2) and for hybrid images where the internal and external features came from two different source images (experiment 3) for five observers with central vision loss and four age-matched control observers. When recognizing familiar face images, approximately 40% of the fixations of observers with central vision loss was centered on the external features of faces. The recognition accuracy was higher for images containing only external features (66.8 ± 3.3% correct) than for images containing only internal features (35.8 ± 15.0%), a finding contradicting that of control observers. For hybrid face images, observers with central vision loss responded more accurately to the external features (50.4 ± 17.8%) than to the internal features (9.3 ± 4.9%), whereas control observers did not show the same bias toward responding to the external features. Contrary to people with normal vision who rely more on the internal features of face images for recognizing familiar faces, individuals with central vision loss show a higher dependence on using external features of face images.

  20. Ascorbate-apatite composite and ascorbate-FGF-2-apatite composite layers formed on external fixation rods and their effects on cell activity in vitro.

    PubMed

    Wang, Xiupeng; Ito, Atsuo; Sogo, Yu; Li, Xia; Tsurushima, Hideo; Oyane, Ayako

    2009-09-01

    Ascorbate-apatite and ascorbate-fibroblast growth factor-2 (FGF-2)-apatite composite layers were successfully formed on anodically oxidized Ti rods clinically used for external fixation by a one-step procedure at 25 degrees C, using a metastable supersaturated calcium phosphate solution supplemented with l-ascorbic acid phosphate magnesium salt n-hydrate (AsMg) and FGF-2. The AsMg-apatite and AsMg-FGF-2-apatite composite layers were evaluated in vitro using fibroblastic NIH3T3 and osteoblastic MC3T3-E1 cells. The AsMg-FGF-2-apatite composite layer markedly enhanced the NIH3T3 cell proliferation and procollagen type capital I, Ukrainian gene expression. Without FGF-2, the AsMg-apatite composite layer whose ascorbate content was 3.64+/-1.27microgcm(-2) obviously enhanced osteoblastic proliferation and differentiation. However, the AsMg-FGF-2-apatite composite layers whose FGF-2 contents were from 0.15+/-0.03 to 0.31+/-0.04microgcm(-2) inhibited osteoblastic differentiation in vitro. Thus, the AsMg-FGF-2-apatite composite layer should be precipitated on the surface of external fixators attached to skin and soft tissue. On the other hand, the AsMg-apatite composite layer should be precipitated at the part attached to bone tissue.

  1. Influence of meditation on anti-correlated networks in the brain.

    PubMed

    Josipovic, Zoran; Dinstein, Ilan; Weber, Jochen; Heeger, David J

    2011-01-01

    Human experiences can be broadly divided into those that are external and related to interaction with the environment, and experiences that are internal and self-related. The cerebral cortex appears to be divided into two corresponding systems: an "extrinsic" system composed of brain areas that respond more to external stimuli and tasks and an "intrinsic" system composed of brain areas that respond less to external stimuli and tasks. These two broad brain systems seem to compete with each other, such that their activity levels over time is usually anti-correlated, even when subjects are "at rest" and not performing any task. This study used meditation as an experimental manipulation to test whether this competition (anti-correlation) can be modulated by cognitive strategy. Participants either fixated without meditation (fixation), or engaged in non-dual awareness (NDA) or focused attention (FA) meditations. We computed inter-area correlations ("functional connectivity") between pairs of brain regions within each system, and between the entire extrinsic and intrinsic systems. Anti-correlation between extrinsic vs. intrinsic systems was stronger during FA meditation and weaker during NDA meditation in comparison to fixation (without mediation). However, correlation between areas within each system did not change across conditions. These results suggest that the anti-correlation found between extrinsic and intrinsic systems is not an immutable property of brain organization and that practicing different forms of meditation can modulate this gross functional organization in profoundly different ways.

  2. Bilateral tibial lengthening over the nail: our experience of 143 cases.

    PubMed

    Motallebi Zadeh, Nader; Mortazavi, Seyedeh Hamideh; Khaki, Siavash; Heidari, Kazem; Karbasi, Ashraf; Ostad Rahimi, Sedigheh

    2014-09-01

    Using lengthening over an intramedullary nail as a technique for cosmetic purposes improves the individuals' quality of life and provides more satisfactory results due to less external fixator period. This study reports a case series of 143 individuals who underwent bilateral tibial lengthening over an intramedullary nail for cosmetic purposes together with the review of parameters related to the surgery and complications. Level of satisfaction was measured with the standard visual analog scale at least 1 year after removal of external fixator. In this study, mean (SD) age of patients was 26.6 (7.26) years. 85 (59.4%) participants were male and 58 (40.6%) were female. Mean end lengthening of all individuals was 6.65 cm. The mean external fixator period was 93.7 days. Complication rate was 0.74 per segment but it decreased to 0.45 when pin-tract infection was excluded. Complications were categorized based on Paley et al.'s classification as 129 problems, 85 obstacles and no sequelae. Interestingly, 44 (30.8%) individuals had no problem and obstacle. Lengthening over an intramedullary nail provides bone formation in equal quality to that obtained by the conventional Ilizarov method, along with lower rate of complications. The large number of individuals involved in our study is a remarkable benefit which could be used as an appropriate sample to compare results for outcomes and complications.

  3. Management of simple (types A and B) closed tibial shaft fractures using percutaneous lag-screw fixation and Ilizarov external fixation in adults.

    PubMed

    El-Sayed, Mohamed; Atef, Ashraf

    2012-10-01

    Although intramedullary fixation of closed simple (type A or B) diaphyseal tibial fractures in adults is well tolerated by patients, providing lower morbidity rates and better mobility, it is associated with some complications. This study evaluated the results of managing these fractures using percutaneous minimal internal fixation using one or more lag screws, and Ilizarov external fixation. This method was tested to evaluate its efficacy in immediate weight bearing, fracture healing and prevention of any post-immobilisation stiffness of the ankle and knee joints. This randomised blinded study was performed at a referral, academically supervised, level III trauma centre. Three hundred and twenty-four of the initial 351 patients completed this study and were followed up for a minimum of 12 (12-88) months. Patient ages ranged from 20 to 51 years, with a mean of 39 years. Ankle and knee movements and full weight bearing were encouraged immediately postoperatively. Solid union was assessed clinically and radiographically. Active and passive ankle and knee ranges of motion were measured and compared with the normal side using the Wilcoxon signed rank test for matched pairs. Subjective Olerud and Molander Ankle Score was used to detect any ankle joint symptoms at the final follow-up. No patient showed delayed or nonunion. All fractures healed within 95-129 days. Based on final clinical and radiographic outcomes, this technique proves to be adequate for managing simple diaphyseal tibial fractures. On the other hand, it is relatively expensive, technically demanding, necessitates exposure to radiation and patients are expected to be frame friendly.

  4. [Tibial press-fit fixation of flexor tendons for reconstruction of the anterior cruciate ligament].

    PubMed

    Ettinger, M; Liodakis, E; Haasper, C; Hurschler, C; Breitmeier, D; Krettek, C; Jagodzinski, M

    2012-09-01

    Press-fit fixation of hamstring tendon autografts for anterior cruciate ligament reconstruction is an interesting technique because no hardware is necessary. This study compares the biomechanical properties of press-fit fixations to an interference screw fixation. Twenty-eight human cadaveric knees were used for hamstring tendon explantation. An additional bone block was harvested from the tibia. We used 28 porcine femora for graft fixation. Constructs were cyclically stretched and then loaded until failure. Maximum load to failure, stiffness and elongation during failure testing and cyclic loading were investigated. The maximum load to failure was 970±83 N for the press-fit tape fixation (T), 572±151 N for the bone bridge fixation (TS), 544±109 N for the interference screw fixation (I), 402±77 N for the press-fit suture fixation (S) and 290±74 N for the bone block fixation technique (F). The T fixation had a significantly better maximum load to failure compared to all other techniques (p<0.001). This study demonstrates that a tibial press-fit technique which uses an additional bone block has better maximum load to failure results compared to a simple interference screw fixation.

  5. The Impact of Nitinol Staples on the Compressive Forces, Contact Area, and Mechanical Properties in Comparison to a Claw Plate and Crossed Screws for the First Tarsometatarsal Arthrodesis.

    PubMed

    Aiyer, Amiethab; Russell, Nicholas A; Pelletier, Matthew H; Myerson, Mark; Walsh, William R

    2016-06-01

    Background The optimal fixation method for the first tarsometatarsal arthrodesis remains controversial. This study aimed to develop a reproducible first tarsometatarsal testing model to evaluate the biomechanical performance of different reconstruction techniques. Methods Crossed screws or a claw plate were compared with a single or double shape memory alloy staple configuration in 20 Sawbones models. Constructs were mechanically tested in 4-point bending to 1, 2, and 3 mm of plantar displacement. The joint contact force and area were measured at time zero, and following 1 and 2 mm of bending. Peak load, stiffness, and plantar gapping were determined. Results Both staple configurations induced a significantly greater contact force and area across the arthrodesis than the crossed screw and claw plate constructs at all measurements. The staple constructs completely recovered their plantar gapping following each test. The claw plate generated the least contact force and area at the joint interface and had significantly greater plantar gapping than all other constructs. The crossed screw constructs were significantly stiffer and had significantly less plantar gapping than the other constructs, but this gapping was not recoverable. Conclusions Crossed screw fixation provides a rigid arthrodesis with limited compression and contact footprint across the joint. Shape memory alloy staples afford dynamic fixation with sustained compression across the arthrodesis. A rigid polyurethane foam model provides an anatomically relevant comparison for evaluating the interface between different fixation techniques. Clinical Relevance The dynamic nature of shape memory alloy staples offers the potential to permit early weight bearing and could be a useful adjunctive device to impart compression across an arthrodesis of the first tarsometatarsal joint. Therapeutic, Level V: Bench testing. © 2015 The Author(s).

  6. A Biomechanical Comparison of Distal Fixation for Bridge Plating in a Distal Radius Fracture Model.

    PubMed

    Alluri, Ram K; Bougioukli, Sofia; Stevanovic, Milan; Ghiassi, Alidad

    2017-09-01

    To compare the biomechanical properties of second versus third metacarpal distal fixation when using a radiocarpal spanning distraction plate in an unstable distal radius fracture model. Biomechanical evaluation of the radiocarpal spanning distraction plate comparing second versus third metacarpal distal fixation was performed using a standardized model of an unstable wrist fracture in 10 matched-pair cadaveric specimens. Each fixation construct underwent a controlled cyclic loading protocol in flexion and extension. The resultant displacement and stiffness were calculated at the fracture site. After cyclic loading, each specimen was loaded to failure. The stiffness, maximum displacement, and load to failure were compared between the 2 groups. Cyclic loading in flexion demonstrated that distal fixation to the third metacarpal resulted in greater stiffness compared with the second metacarpal. There was no significant difference between the 2 groups with regards to maximum displacement at the fracture site in flexion. Cyclic loading in extension demonstrated no significant difference in stiffness or maximum displacement between the 2 groups. The average load to failure was similar for both groups. Fixation to the third metacarpal resulted in greater stiffness in flexion. All other biomechanical parameters were similar when comparing distal fixation to the second or third metacarpal in distal radius fractures stabilized with a spanning internal distraction plate. The treating surgeon should choose distal metacarpal fixation primarily based on fracture pattern, alignment, and soft tissue integrity. If a stiffer construct is desired, placement of the radiocarpal spanning plate at the third metacarpal is preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  7. Longitudinal bracketed epiphysis of proximal phalanx of the great toe with congenital hallux varus managed simultaneously with monorail external fixator: a case report.

    PubMed

    Verma, Vineet; Batra, Amit; Singla, Rohit; Gogna, Paritosh; Magu, Narender; Gupta, Rakesh

    2014-02-01

    Longitudinal bracketed epiphysis (delta phalanx) is a rare congenital anomaly that affects phalanges in the hand more commonly than toes. We present a rare case of congenital hallux varus with longitudinal bracketed epiphysis of proximal phalanx with bifid distal phalanx of the great toe, which was managed with monorail type of external fixator. To the best of our knowledge, this is the first report of its successful implementation in simultaneous treatment of longitudinal bracketed epiphysis of the proximal phalanx of the great toe and hallux varus. Apart from adding to the literature a case of rare subtype of delta phalanx with hallux varus, the present study highlights the role of a reliable alternative in its management.

  8. Relative strength of tailor's bunion osteotomies and fixation techniques.

    PubMed

    Haddon, Todd B; LaPointe, Stephan J

    2013-01-01

    A paucity of data is available on the mechanical strength of fifth metatarsal osteotomies. The present study was designed to provide that information. Five osteotomies were mechanically tested to failure using a materials testing machine and compared with an intact fifth metatarsal using a hollow saw bone model with a sample size of 10 for each construct. The osteotomies tested were the distal reverse chevron fixated with a Kirschner wire, the long plantar reverse chevron osteotomy fixated with 2 screws, a mid-diaphyseal sagittal plane osteotomy fixated with 2 screws, the mid-diaphyseal sagittal plane osteotomy fixated with 2 screws, and an additional cerclage wire and a transverse closing wedge osteotomy fixated with a box wire technique. Analysis of variance was performed, resulting in a statistically significant difference among the data at p <.0001. The Tukey-Kramer honestly significant difference with least significant differences was performed post hoc to separate out the pairs at a minimum α of 0.05. The chevron was statistically the strongest construct at 130 N, followed by the long plantar osteotomy at 78 N. The chevron compared well with the control at 114 N, and they both fractured at the proximal model to fixture interface. The other osteotomies were statistically and significantly weaker than both the chevron and the long plantar constructs, with no statistically significant difference among them at 36, 39, and 48 N. In conclusion, the chevron osteotomy was superior in strength to the sagittal and transverse plane osteotomies and similar in strength and failure to the intact model. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Pediatric distal femur fixation by proximal humeral plate.

    PubMed

    Abdelgawad, Amr Atef; Kanlic, Enes M

    2013-12-01

    Distal femoral metaphyseal fractures are common injuries in children. Multiple treatment options have been described for this type of injury. For older children with distal metaphyseal fracture, there is still no optimal method of fixation. We propose that the commonly used proximal humeral plate can provide good method of fixation for this fracture in adolescents. Two children (12 and 14 years old) with distal metaphyseal femoral fracture were treated with proximal humeral plate. We describe the surgical technique and postoperative management. The two children healed with good alignment and full range of motion of the knee. No external immobilization (other than knee immobilizer for the first 2 weeks) was used. We concluded that proximal humeral plate can provide adequate fixation for teenagers with distal femoral metaphyseal fracture. It is readily available; provide multiple options for screw fixation in the distal part of the fracture and fits easily on the distal part of the femur proximal to the physis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Reduction and temporary stabilization of Tile C pelvic ring injuries using a posteriorly based external fixation system.

    PubMed

    Martin, Murphy P; Rojas, David; Mauffrey, Cyril

    2018-07-01

    Tile C pelvic ring injuries are challenging to manage even in the most experienced hands. The majority of such injuries can be managed using percutaneous reduction techniques, and the posterior ring can be stabilized using percutaneous transiliac-transsacral screw fixation. However, a subgroup of patients present with inadequate bony corridors, significant sacral zone 2 comminution or significant lateral/vertical displacement of the hemipelvis through a complete sacral fracture. Percutaneous strategies in such circumstances can be dangerous. Those patients may benefit from prone positioning and open reduction of the sacral fracture with fixation through tension band plating or lumbo-pelvic fixation. Soft tissue handling is critical, and direct reduction techniques around the sacrum can be difficult due to the complex anatomy and the fragile nature of the sacrum making clamp placement and tightening a challenge. In this paper, we propose a mini-invasive technique of indirect reduction and temporary stabilization, which is soft tissue friendly and permits maintenance of reduction during definitive fixation surgical.

  11. Joint Distraction Treatments of Intra-Articular Fracture-Induced Posttraumatic Osteoarthritis in a Large Animal Model

    DTIC Science & Technology

    2017-10-01

    that was developed this Year for use in the upcoming Aim 2 studies. 15. SUBJECT TERMS External Fixator, Fracture Fixation Delay, Yucatan Minipig 16... Yucatan minipig model of PTOA after IAF that was developed during our previous work (W81XWH-10-1-0864) to investigate the use of joint distraction to...proactive treatment for PTOA. 2. KEYWORDS Post-traumatic Osteoarthritis Intra-articular Fracture Yucatan Miniature Pig Impact Ankle Cartilage

  12. External fixation for displaced intra-articular fractures of the calcaneum.

    PubMed

    Magnan, B; Bortolazzi, R; Marangon, A; Marino, M; Dall'Oca, C; Bartolozzi, P

    2006-11-01

    A minimally-invasive procedure using percutaneous reduction and external fixation can be carried out for Sanders' type II, III and IV fractures of the os calcis. We have treated 54 consecutive closed displaced fractures of the calcaneum involving the articular surface in 52 patients with the Orthofix Calcaneal Mini-Fixator. Patients were followed up for a mean of 49 months (27 to 94) and assessed clinically with the Maryland Foot Score and radiologically with radiographs and CT scans, evaluated according to the Score Analysis of Verona. The clinical results at follow-up were excellent or good in 49 cases (90.7%), fair in two (3.7%) and poor in three (5.6%). The mean pre-operative Böhler's angle was 6.98 degrees (5.95 degrees to 19.86 degrees), whereas after surgery the mean value was 21.94 degrees (12.58 degrees to 31.30 degrees) (p < 0.01). Excellent results on CT scanning were demonstrated in 24 cases (44.4%), good in 25 (46.3%), fair in three (5.6%) and poor in two (3.7%). Transient local osteoporosis was observed in ten patients (18.5%), superficial pin track infection in three (5.6%), and three patients (5.6%) showed thalamic displacement following unadvised early weight-bearing. The clinical results appear to be comparable with those obtainable with open reduction and internal fixation, with the advantages of reduced risk using a minimally-invasive technique.

  13. Segmental transport after unreamed intramedullary nailing. Preliminary report of a "Monorail" system.

    PubMed

    Raschke, M J; Mann, J W; Oedekoven, G; Claudi, B F

    1992-09-01

    The Ilizarov method of segmental bone transport has been shown to be an alternative to more conventional treatments of posttraumatic bony defects. After extensive clinical experience with the unreamed tibial nail in open fractures up to Grade IIIb, a new monorail fixation system for callus distraction and segmental bone transport was devised. This Monorail system is composed of an unreamed intramedullary (IM) nail and a unilateral AO distraction device. The new fixation method and the preliminary clinical experience are reported here. Four patients who previously sustained Grades II-IIIb open tibial fractures had an average bony defect of 9 cm. Two patients had previous bony infections. All patients had had serial debridements and myocutaneous flaps were required in three patients. An unreamed IM nail was inserted, and the transport device was applied. After an osteotomy, segmental transport was carried out until docking was achieved. The external fixator was removed after interlocking of the transported segment. The mean duration of external fixation was 17.9 days/cm and the mean period until roentgenographic consolidation of the distraction and nonunion site was 41.2 days/cm. There were two pin-tract infections but no IM infections. One nail broke after osseous consolidation of the regenerate at the distal interlocking site and required exchange. The goal of transport was achieved in all cases without angular or rotational deformity or length discrepancy. There were no neurovascular injuries.

  14. Management of Open Tibial Shaft Fractures: Does the Timing of Surgery Affect Outcomes?

    PubMed

    Duyos, Oscar A; Beaton-Comulada, David; Davila-Parrilla, Ariel; Perez-Lopez, Jose Carlos; Ortiz, Krystal; Foy-Parrilla, Christian; Lopez-Gonzalez, Francisco

    2017-03-01

    Open tibial shaft fractures require emergent care. Treatment with intravenous antibiotics and fracture débridement within 6 to 24 hours is recommended. Few studies have examined outcomes when surgical treatment is performed >24 hours after occurrence of the fracture. This retrospective study included 227 patients aged ≥18 years with isolated open tibial shaft fractures in whom the time to initial débridement was >24 hours. The statistical analysis was based on time from injury to surgical débridement, Gustilo-Anderson classification, method of fixation, union status, and infection status. Fractures débrided within 24 to 48 hours and 48 to 96 hours after injury did not show a statistically significant difference in terms of infection rates (P = 0.984). External fixation showed significantly greater infection rates (P = 0.044) and nonunion rates (P = 0.001) compared with intramedullary nailing. Open tibial shaft fractures should be débrided within 24 hours after injury. Our data indicate that after the 24-hour period and up to 4 days, the risk of infection remains relatively constant independent of the time to débridement. Patients treated with external fixation had more complications than did patients treated with other methods of fixation. Primary reamed intramedullary nailing appears to be a reasonable option for the management of Gustilo-Anderson types 1 and 2 open tibial shaft fractures. Level III retrospective study.

  15. Relative stability of tension band versus two-cortex screw fixation for treating fifth metatarsal base avulsion fractures.

    PubMed

    Husain, Z S; DeFronzo, D J

    2000-01-01

    This study assesses the strength of fixating avulsion fractures of the fifth metatarsal base with a 4.0-mm partially threaded cancellous screw crossing two cortices as compared to tension banding. Our data showed statistically significant fixation strength improvement over tension banding for avulsion fractures (p < 0.02) in both polystyrene foam models and fresh, nonpreserved frozen cadaveric samples. In cadavers, the screw fixations were able to withstand more than three times the load sustained by the tension band fixations. The study utilized the Instron 8500 tensiometer to apply physiologic loads to test the constructs until failure. The displacement and load data at failure show the limitations of both fixations. By increasing the load resistance while maintaining compression, the bicortical cancellous screw fixation created greater stability at the avulsion fracture of the fifth metatarsal base as compared to tension band stabilization.

  16. Biomechanical Analysis of Lateral Lumbar Interbody Fusion Constructs with Various Fixation Options: Based on a Validated Finite Element Model.

    PubMed

    Zhang, Zhenjun; Fogel, Guy R; Liao, Zhenhua; Sun, Yitao; Liu, Weiqiang

    2018-06-01

    Lateral lumbar interbody fusion using cage supplemented with fixation has been used widely in the treatment of lumbar disease. A combined fixation (CF) of lateral plate and spinous process plate may provide multiplanar stability similar to that of bilateral pedicle screws (BPS) and may reduce morbidity. The biomechanical influence of the CF on cage subsidence and facet joint stress has not been well described. The aim of this study was to compare biomechanics of various fixation options and to verify biomechanical effects of the CF. The surgical finite element models with various fixation options were constructed based on computed tomography images. The lateral plate and posterior spinous process plate were applied (CF). The 6 motion modes were simulated. Range of motion (ROM), cage stress, endplate stress, and facet joint stress were compared. For the CF model, ROM, cage stress, and endplate stress were the minimum in almost all motion modes. Compared with BPS, the CF reduced ROM, cage stress, and endplate stress in all motion modes. The ROM was reduced by more than 10% in all motion modes except for flexion; cage stress and endplate stress were reduced more than 10% in all motion modes except for rotation-left. After interbody fusion, facet joint stress was reduced substantially compared with the intact conditions in all motion modes except for flexion. The combined plate fixation may offer an alternative to BPS fixation in lateral lumbar interbody fusion. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. The Use of a Multiplanar, Multi-Axis External Fixator to Achieve Knee Arthrodesis in a Worst Case Scenario: A Case Series

    PubMed Central

    Raskolnikov, Dima; Slover, James D.; Egol, Kenneth A.

    2013-01-01

    Background One of the most catastrophic outcomes following total knee arthroplasty (TKA) is a chronic periprosthetic infection with concomitant failure of the knee extensor mechanism. This study retrospectively reviewed the clinical records of 7 patients who were treated with a 6 axis circular external fixation frame (Taylor Spatial Frame (TSF)) for this condition. Fusion was achieved in 5 of 7 patients (71%) at an average of 8.4 months after surgery. Complications occurred in the treatment of 5 of 7 patients (71%). Infection was controlled in all cases. The TSF presents another valuable tool, which the orthopaedic surgeon should consider when treating these difficult cases. Purpose To evaluate the use of the Taylor Spatial Frame (TSF) to achieve knee arthrodesis in patients with chronically infected total knee arthroplasties (TKAs) with concomitant failure of the knee extensor mechanism. Methods We retrospectively evaluated the clinical records of 7 patients who were referred to our tertiary care orthopaedic medical center with multiple failed knee arthroplasties, chronic draining infection and complete loss of the extensor mechanism. All patients were treated with a similar protocol including, debridement and bony stabilization with an adjustable, 6 axis circular external fixation frame (TSF). Hospital charts were reviewed for sociodemographic information, surgical details, hospital course and complications. Radiographs were reviewed for healing and alignment. Follow up included clinical examination and radiographs. Results The mean age of the patients was 70.9 years (range, 59 – 83 years) at the time of application of the TSF. There were 3 men and 4 women. The average time between TKA and diagnosis of infection was 30.7 months (range, 2.6 – 67.0 months). The 7 patients had undergone an average of 3.3 prior surgical procedures (range, 2-4 procedures) on the ipsilateral extremity. Fusion was achieved in 5 of 7 patients (71%) at an average of 8.4 months after surgery (range, 6 – 10.5 months). Complications occurred in the treatment of 5 of 7 patients (71%) and included infection at the site of the pin tracks (5 patients), antibiotic- induced acute renal failure (1 patient), wound breakdown requiring flap closure (1 patient), and femur fracture secondary to a fall after placement of the antibiotic spacer but before application of the TSF (1 patient). The 2 patients in whom failure of fusion occurred returned to ambulation with an assistive device. Infection was controlled in all cases. Conclusion Fusion and complication rates in this cohort are comparable to those reported in previous studies using other techniques to achieve external fixation. The TSF is a versatile external fixator that offers another tool, which the orthopaedic surgeon should consider when treating these difficult cases. PMID:24027456

  18. Acceleration and holographic studies on different types of dynamization of external fixators of the bones

    NASA Astrophysics Data System (ADS)

    Podbielska, Halina; Kasprzak, Henryk T.; Voloshin, Arkady S.; Pennig, Dietmar; von Bally, Gert

    1992-08-01

    The unilateral axially dynamic fixator (Orthofix) was mounted on a sheep tibial shaft. Three fixation modes: static, dynamic controlled, and dynamic free were examined by means of double exposure holographic interferometry. Simultaneously, the acceleration was measured by an accelerometer and displayed on the monitor together with loading characteristics. The first exposure was made before the acting force was applied to the tibia plateau. The second one after the moment when the acceleration wave started to propagate through the specimen. We stated that in the case of dynamization less torsion occurs at the fracture site. So far, we have not been able to determine any correlation between results of holographic and accelerometric measurements.

  19. [Treatment of bacterial infection in the interphalangeal joints of the hand].

    PubMed

    Vorderwinkler, K-P; Mühldorfer, M; Pillukat, T; van Schoonhoven, J

    2011-07-01

    Radical debridement of joint infection, prevention of further infection-related tissue destruction. Septic arthritis of interphalangeal joints in the thumb and fingers. Extensive soft tissue defects. Severe impairment of blood circulation, finger gangrene. Noncompliance for immobilization or for treatment with external fixator. Arthrotomy and irrigation with isotonic solution. Radical tissue debridement. Joint preservation possible only in the absence of infection-related macroscopic cartilage damage. Otherwise, resection of the articular surfaces and secondary arthrodesis. Insertion of antibiotic-coated devices. Temporary immobilization with external fixator. Inpatient postoperative treatment with 5-day intravenous administration of a second-generation cephalosporine (e.g., Cefuroxim®) followed by 7-10 days oral application. Adaptation of antibiotics according to antibiogram results. In joint-preserving procedures, radiographs and fixator removal after 4 weeks, active joint mobilization. If joint surfaces were resected, removal of fixator after 6 weeks; arthrodesis under 3-day intravenous broad-band antibiotic prophylaxis. Splint immobilization until consolidation (6-8 weeks). In 10 of 40 patients, the infected joint could be preserved. All infections healed. After an average duration of therapy of 6 (3-11) weeks, 4 individuals were free of complaints, and 6 patients had minor symptoms. Overall range of motion in the affected finger was reduced by 25-50° in 5 patients. All patients could return to work after 6.6 (4-11) weeks. A total of 30 patients were treated with joint resection and external fixator. After 5.6 (4-8) weeks, arthrodesis was performed, leading to consolidation in 29 patients. One patient underwent amputation after 4 months due to delayed gangrene. Treatment duration was 15.7 (7-25) weeks. Eight patients reported no complaints, 14 suffered mild symptoms, 5 had moderate, and 3 had severe symptoms in daily life. In 15 cases, range of motion was diminished by 10-80° in the remaining joints of the affected finger. Patients could return to work after 16.2 (6-28) weeks.

  20. [Curative effect analysis on closed reduction and external fixator under local anesthesia for the treatment of intertrochanteric fracture in elderly patients with high-risk].

    PubMed

    Wang, Zeng-ping; Liu, Lin; Xue, Wen; Zhou, Hui-ru; Song, Yu-xin; Cai, Li-yang; Cheng, Xian-tang; Qian, Yao-wen

    2016-06-01

    To explore clinical efficacy of closed reduction and external fixation under local anesthesia for the treatment of high-risk elderly patients with intertrochanteric fracture. From March 2013 to March 2015, 10 patients with intertrochanteric fractures treated with closing reduction and external fixator under local anesthesia were analyszed, including 4 males and 6 females, aged from 69 to 88 years old with an average of 75.2 years old. All fractures were caused by injury and classified to type I (5 cases), II (3 cases), and V (2 cases) according to Evans classification. According to American Society of Anesthesiologists (ASA), 6 cases were type III and 4 cases were type IV. Blood loss,operative time,hospital stays, postoperative complications, ambulation time and fracture healing time were observed, and Harris scoring were used to evaluate hip joint function. All patients were followed up from 3 to 23 months with an average of 13.1 months. One patient with chronic obstructive pulmonary disease died for non-operation reason at 4 months after operation, the other fractures were healed at stage I, the mean fracture healing time was 5.6 months. There were no coxa vara, lower limb venous thrombosis, loosen and remove of needle passage. The average operative time was 46 min, blood loss was (35.00 ± 8.46) ml without blood transfusion. One patient was occurred pulmonary infection and stent-tract infection on the 2 nd and 3 rd day after operation, and improved with active anti-infection and dressing change; the other patients gone to ground activity at 4.2 d after operation. The patients stayed hospital for 10.6 d on average. According to Harris scoring at final following-up, the total score was 83.42 ± 3.27, 3 cases obtained excellent results, 5 cases good and 1 case poor. Closed reduction and external fixation under local anesthesia in treating high-risk elderly patients with intertrochanteric fracture,which has advantages of shorter operative time, less blood loss, good recovery of postoperative function, is a safe, stable and economic method.

  1. Acrylic Resin Molding Based Head Fixation Technique in Rodents.

    PubMed

    Roh, Mootaek; Lee, Kyungmin; Jang, Il-Sung; Suk, Kyoungho; Lee, Maan-Gee

    2016-01-12

    Head fixation is a technique of immobilizing animal's head by attaching a head-post on the skull for rigid clamping. Traditional head fixation requires surgical attachment of metallic frames on the skull. The attached frames are then clamped to a stationary platform resulting in immobilization of the head. However, metallic frames for head fixation have been technically difficult to design and implement in general laboratory environment. In this study, we provide a novel head fixation method. Using a custom-made head fixation bar, head mounter is constructed during implantation surgery. After the application of acrylic resin for affixing implants such as electrodes and cannula on the skull, additional resins applied on top of that to build a mold matching to the port of the fixation bar. The molded head mounter serves as a guide rails, investigators conveniently fixate the animal's head by inserting the head mounter into the port of the fixation bar. This method could be easily applicable if implantation surgery using dental acrylics is necessary and might be useful for laboratories that cannot easily fabricate CNC machined metal head-posts.

  2. [Missed diagnosis of hiding posterior marginal fracture of ankle with pronation-external rotation type and its treatment].

    PubMed

    Wang, Jia; Zhang, Yun-Tong; Zhang, Chun-Cai; Tang, Yang

    2014-01-01

    To analyze causes of missed diagnosis of hiding post-malleolar fractures in treating ankle joint fractures of pronation-external rotation type according to Lauge-Hansen classification and assess its medium-term outcomes. Among 103 patients with ankle joint fracture of pronation-external rotation type treated from March 2002 to June 2010,9 patients were missed diagnosis,including 6 males and 3 females,with a mean age of 35.2 years old (ranged, 18 to 55 years old) . Four patients were diagnosed during operation, 2 patients were diagnosed 2 or 3 days after first surgery and 3 patients came from other hospital. All the patients were treated remedially with lag screws and lock plates internal fixation. After operation,ankle joint function was evaluated according to American Orthopaedic Foot and Ankle Society (AOFAS). All the 9 patients were followed up, and the duration ranged from 14 to 30 months (averaged, 17 months). No incision infection was found, and all incision healed at the first stage. At the latest follow-up, AOFAS was 83.0 +/- 4.4, the score of 4 patients diagnosed during operation was 85.0 +/- 2.9, and the score of 5 patients treated by secondary operation was 81.0 +/- 5.3. All the patients got fracture union observed by X-ray at a mean time of 2.2 months after operation. There were no complications such as internal fixation loosing, broken and vascular or nerve injuries. Ankle joint fracture of pronation-external rotation type may be combined with hiding post-malleolar fractures. So to patients with ankle joint fracture of pronation-external rotation type, lateral X-ray should be read carefully, and if necessary, CT or MRI examination should be performed. If adding lateral X-ray examination after reduction of exterior and interior ankle joint fixation, the missed diagnosis may be avoided.

  3. Temporary Iliac Fixation to Salvage an Acute L4 Chance Fracture: Following Pedicle Screw Fixation for Adolescent Idiopathic Scoliosis.

    PubMed

    Kato, So; Lewis, Stephen J

    2017-03-01

    A case report. The aim of this study was to describe a technique of temporary distal fixation to the ilium to salvage an acute L4 fracture following a T3-L4 kyphoscoliosis correction. Pedicle fracture is a possible complication in pedicle screw fixation for scoliosis, which may lead to postoperative instability, resulting in loss of fixation and pseudoarthrosis. This report highlights the salvage treatment of a chance fracture that occurred in the lower instrumented vertebra following deformity correction for adolescent idiopathic scoliosis (AIS) without sacrificing further distal motion segments. A retrospective chart and radiograph review of a 13-year-old female who underwent surgical treatment for correction of AIS was performed. Following a T3-L4 correction with apical posterior column releases, an L4 Chance fracture with loss of distal fixation occurred on post-op day 3. Following an unsuccessful salvage with an infralaminar hook, a second revision was performed replacing the hook and adding bilateral temporary fixation to the ilium connected to the distal ends of the main rods through side-to-side connectors. The temporary fixation was removed 6 months later with successful healing of the fracture maintenance of the scoliosis correction at 2-year follow-up. Temporary extension of the construct to the ilium was successfully utilized in this case to salvage an acute L4 Chance fracture that occurred following a T3 to L4 construct for kyphoscoliosis. With this technique, successful reduction and healing of the fracture occurred with maintenance of the deformity correction without the need to fuse further distal segments. 4.

  4. A technique for correction of equinus contracture using a wire fixator and elastic tension.

    PubMed

    Melvin, J Stuart; Dahners, Laurence E

    2006-02-01

    Equinus contracture often is a complication of trauma, burns, or neurologic deficit. Many patients with contractures secondary to trauma or burns have poor soft tissue, which makes invasive correction a less appealing option. The Ilizarov external fixator has been used as a less invasive attempt to correct equinus contracture. We describe our "dynamic" technique and present a clinical patient series using a variation of the unconstrained Ilizarov technique, which uses elastic bands rather than threaded rods to supply the corrective force.

  5. Locked plating of comminuted distal femur fractures: does unlocked screw placement affect stability and failure?

    PubMed

    Cui, Shari; Bledsoe, J G; Israel, Heidi; Watson, J T; Cannada, Lisa K

    2014-02-01

    Locked plates provide greater stiffness, possibly at the expense of fracture healing. The purpose of this study is to evaluate construct stiffness of distal femur plates as a function of unlocked screw position in cadaveric distal femur fractures. Osteoporotic cadaveric femurs were used. Four diaphyseal bridge plate constructs were created using 13-hole distal femur locking plates, all with identical condylar fixation. Constructs included all locked (AL), all unlocked (AUL), proximal unlocked (PUL), and distally unlocked (DUL) groups. Constructs underwent cyclic axial loading with increasing force per interval. Data were gathered on axial stiffness, torsional stiffness, maximum torque required for 5-degree external rotation, and axial force to failure. Twenty-one specimens were divided into AL, AUL, PUL, and DUL groups. Axial stiffness was not significantly different between the constructs. AL and PUL demonstrated greater torsional stiffness, maximum torque, and force to failure than AUL and AL showed greater final torsional stiffness and failure force than DUL (P < 0.05). AL and PUL had similar axial, torsion, and failure measures, as did AUL and DUL constructs. All but 2 specimens fractured before medial gap closure during failure tests. Drop-offs on load-displacement curves confirmed all failures. Only the screw nearest the gap had significant effect on torsional and failure stiffness but not axial stiffness. Construct mechanics depended on the type of screw placed in this position. This screw nearest the fracture dictates working length stiffness when the working length itself is constant and in turn determines overall construct stiffness in osteoporotic bone.

  6. Anterior-inferior tibiofibular ligament anatomical repair and augmentation versus trans-syndesmosis screw fixation for the syndesmotic instability in external-rotation type ankle fracture with posterior malleolus involvement: A prospective and comparative study.

    PubMed

    Zhan, Yu; Yan, Xiaoyu; Xia, Ronggang; Cheng, Tao; Luo, Congfeng

    2016-07-01

    Syndesmosis injury is common in external-rotation type ankle fractures (ERAF). Trans-syndesmosis screw fixation, the gold-standard treatment, is currently controversial for its complications and biomechanical disadvantages. The purpose of this study was to introduce a new method of anatomically repairing the anterior-inferior tibiofibular ligament (AITFL) and augmentation with anchor rope system to treat the syndesmotic instability in ERAF with posterior malleolus involvement and to compare its clinical outcomes with that of trans-syndesmosis screw fixation. 53 ERAFs with posterior malleolus involvement received surgery, and the syndesmosis was still unstable after fracture fixation. They were randomised into screw fixation group and AITFL anatomical repair with augmentation group. Reduction quality, syndesmosis diastasis recurrence, pain (VAS score), time back to work, Olerud-Molander ankle score and range of motion (ROM) of ankle were investigated. Olerud-Molander score in AITFL repair group and screw group was 90.4 and 85.8 at 12-month follow-up (P>0.05). Plantar flexion was 31.2° and 34.3° in repair and screw groups (P=0.04). Mal-reduction happened in 5 cases (19.2%) in screw group while 2 cases (7.4%) in repair group. Postoperative syndesmosis re-diastasis occurred in 3 cases in screw group while zero in repair group (P>0.05). Pain score was similar between the two groups (P>0.05). Overall complication rate and back to work time were 26.9% and 3.7% (P=0.04), 7.15 months and 5.26 months (P=0.02) in screw group and repair group, respectively. For syndesmotic instability in ERAF with posterior malleolus involvement, the method of AITFL anatomical repair and augmentation with anchor rope system had an equivalent functional outcome and reduction, earlier rehabilitation and less complication compared with screw fixation. It can be selected as an alternative. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. The contribution of nitrogen fixation by cyanobacteria to particulate organic nitrogen in a constructed wetland

    NASA Astrophysics Data System (ADS)

    Zhang, X.; PAN, X.; MA, M.; Li, W.; Cui, L.

    2016-12-01

    N-fixing cyanobacteria can create extra nitrogen for aquatic ecosystems. Previous studies reported inconsistence patterns of the contribution of biological nitrogen fixation to the nitrogen pools in aquatic ecosystems. However, there were few studies concerning the effect of fixed nitrogen by cyanobacteria on the nitrogen removal efficiency in constructed wetlands. This study was performed at the Beijing Wildlife Rescue and Rehabilitation Centre, where a constructed lake for the habitation of waterfowls and a constructed wetland for purifying sewage from the lake are located. The composition of phytoplankton communities, the concentrations of particulate organic nitrogen (PON) and nitrogen fixation rates (Rn) in the constructed lake and the constructed wetland were compared throughout a growing season. We counted the densities of genus Anabaena and Microcystis cells, and explored their relationships with PON and Rn in water. The proportions of PON from various sources, including the ambient N2, waterfowl faeces, wetland sediments and the nitrates, were calculated by the natural abundance of 15N with the IsoSource software. The result revealed that the constructed lake was alternately dominated by Anabaena and Microcystis throughout the growing season, and the Rn was positively correlated with PON and the cell density of Anabaena (P < 0.05). This implied that the fixed nitrogen by N-fixing Anabaena might be utilized by non-N-fixing Microcystis, maintaining the fixed nitrogen with PON form. The ambient N2 composed 0.5 82% and 50.0 84.7% to the PON in the constructed lake and wetland respectively during the growing season. The proportions of PON from N2 increased to more than 80% when the Rn reached the highest in September. The result demonstrated that the nitrogen fixed by Anabaena might be utilized by non-N-fixing Microcystis which formed water blooms in summer. Therefore, the decline of the removal efficiency of PON in the constructed wetland in summer might indirectly result from the nitrogen fixation, since the proliferated algal were difficult to sediment in surface flow wetlands.

  8. Torsional stiffness after subtalar arthrodesis using second generation headless compression screws: Biomechanical comparison of 2-screw and 3-screw fixation.

    PubMed

    Riedl, Markus; Glisson, Richard R; Matsumoto, Takumi; Hofstaetter, Stefan G; Easley, Mark E

    2017-06-01

    Subtalar joint arthrodesis is a common operative treatment for symptomatic subtalar arthrosis. Because excessive relative motion between the talus and calcaneus can delay or prohibit fusion, fixation should be optimized, particularly in patients at risk for subtalar arthrodesis nonunion. Tapered, fully-threaded, variable pitch screws are gaining popularity for this application, but the mechanical properties of joints fixed with these screws have not been characterized completely. We quantified the torsion resistance of 2-screw and 3-screw subtalar joint fixation using this type of screw. Ten pairs of cadaveric subtalar joints were prepared for arthrodesis and fixed using Acutrak 2-7.5 screws. One specimen from each pair was fixed with two diverging posterior screws, and the contralateral joint was fixed using two posterior screws and a third screw directed through the anterior calcaneus into the talar neck. Internal and external torsional loads were applied and joint rotation and torsional stiffness were measured at two torque levels. Internal rotation was significantly less in specimens fixed with three screws. No difference was detectable between 2-screw and 3-screw fixation in external rotation or torsional stiffness in either rotation direction. Both 2-screw and 3-screw fixation exhibited torsion resistance surpassing that reported previously for subtalar joints fixed with two diverging conventional lag screws. Performance of the tapered, fully threaded, variable pitch screws exceeded that of conventional lag screws regardless of whether two or three screws were used. Additional resistance to internal rotation afforded by a third screw placed anteriorly may offer some advantage in patients at risk for nonunion. Copyright © 2017. Published by Elsevier Ltd.

  9. Clinical efficacy and safety of limited internal fixation combined with external fixation for Pilon fracture: A systematic review and meta-analysis.

    PubMed

    Zhang, Shao-Bo; Zhang, Yi-Bao; Wang, Sheng-Hong; Zhang, Hua; Liu, Peng; Zhang, Wei; Ma, Jing-Lin; Wang, Jing

    2017-04-01

    To compare the clinical efficacy and complications of limited internal fixation combined with external fixation (LIFEF) and open reduction and internal fixation (ORIF) in the treatment of Pilon fracture. We searched databases including Pubmed, Embase, Web of science, Cochrane Library and China Biology Medicine disc for the studies comparing clinical efficacy and complications of LIFEF and ORIF in the treatment of Pilon fracture. The clinical efficacy was evaluated by the rate of nonunion, malunion/delayed union and the excellent/good rate assessed by Mazur ankle score. The complications including infections and arthritis symptoms after surgery were also investigated. Nine trials including 498 pilon fractures of 494 patients were identified. The meta-analysis found no significant differences in nonunion rate (RR = 1.60, 95% CI: 0.66 to 3.86, p = 0.30), and the excellent/good rate (RR = 0.95, 95% CI: 0.86 to 1.04, p = 0.28) between LIFEF group and ORIF group. For assessment of infections, there were significant differences in the rate of deep infection (RR = 2.18, 95% CI: 1.34 to 3.55, p = 0.002), and the rate of arthritis (RR = 1.26, 95% CI: 1.03 to 1.53, p = 0.02) between LIFEF group and ORIF group. LIFEF has similar effect as ORIF in the treatment of pilon fractures, however, LIFEF group has significantly higher risk of complications than ORIF group does. So LIFEF is not recommended in the treatment of pilon fracture. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  10. Virtual stress testing of fracture stability in soldiers with severely comminuted tibial fractures.

    PubMed

    Petfield, Joseph L; Hayeck, Garry T; Kopperdahl, David L; Nesti, Leon J; Keaveny, Tony M; Hsu, Joseph R

    2017-04-01

    Virtual stress testing (VST) provides a non-invasive estimate of the strength of a healing bone through a biomechanical analysis of a patient's computed tomography (CT) scan. We asked whether VST could improve management of patients who had a tibia fracture treated with external fixation. In a retrospective case-control study of 65 soldier-patients who had tibia fractures treated with an external fixator, we performed VST utilizing CT scans acquired prior to fixator removal. The strength of the healing bone and the amount of tissue damage after application of an overload were computed for various virtual loading cases. Logistic regression identified computed outcomes with the strongest association to clinical events related to nonunion within 2 months after fixator removal. Clinical events (n = 9) were associated with a low tibial strength for compression loading (p < 0.05, AUC = 0.74) or a low proportion of failed cortical bone tissue for torsional loading (p < 0.005, AUC = 0.84). Using post-hoc thresholds of a compressive strength of four times body-weight and a proportional of failed cortical bone tissue of 5%, the test identified all nine patients who failed clinically (100% sensitivity; 40.9% positive predictive value) and over three fourths of those (43 of 56) who progressed to successful healing (76.8% specificity; 100% negative predictive value). In this study, VST identified all patients who progressed to full, uneventful union after fixator removal; thus, we conclude that this new test has the potential to provide a quantitative, objective means of identifying tibia-fracture patients who can safely resume weight bearing. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:805-811, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. One lesson from arthroplasty to osseointegration in search for better fixation of in-bone implanted prosthesis

    PubMed Central

    Pitkin, Mark

    2011-01-01

    Direct transcutaneous prosthetic attachment (osseointegration) consists of implanting directly into the residuum bone a metal pylon whose external fraction connects the residuum to the external prosthesis. Since the introduction of osseointegration about 20 years ago, the obvious challenge associated with this technology has been the skin-pylon interface as a source of infections. In comparison, the bone-device interface was considered less problematic because of the knowledge and experience inherited from dental implantology and total joint replacement (arthroplasty). Current methods of pylon fixation in osseointegration follow arthroplasty’s paradigm of positioning the pylon’s shaft inside the bone’s medullary canal. However, adopting the medullary canal as a holding compartment for the pylon’s shaft creates the problem of shaft loosening, which has not yet been solved in arthroplasty. PMID:18712634

  12. The Effect of Insertion Technique on Temperatures for Standard and Self-Drilling External Fixation Pins.

    PubMed

    Manoogian, Sarah; Lee, Adam K; Widmaier, James C

    2017-08-01

    No studies have assessed the effects of parameters associated with insertion temperature in modern self-drilling external fixation pins. The current study assessed how varying the presence of irrigation, insertion speed, and force impacted the insertion temperatures of 2 types of standard and self-drilling external fixation half pins. Seventy tests were conducted with 10 trials for 4 conditions on self-drilling pins, and 3 conditions for standard pins. Each test used a thermocouple inside the pin to measure temperature rise during insertion. Adding irrigation to the standard pin insertion significantly lowered the maximum temperature (P <0.001). Lowering the applied force for the standard pin did not have a significant change in temperature rise. Applying irrigation during the self-drilling pin tests dropped average rise in temperature from 151.3 ± 21.6°C to 124.1 ± 15.3°C (P = 0.005). When the self-drilling pin insertion was decreased considerably from 360 to 60 rpm, the temperature decreased significantly from 151.3 ± 21.6°C to 109.6 ± 14.0°C (P <0.001). When the force applied increased significantly, the corresponding self-drilling pin temperature increase was not significant. The standard pin had lower peak temperatures than the self-drilling pin for all conditions. Moreover, slowing down the insertion speed and adding irrigation helped mitigate the temperature increase of both pin types during insertion.

  13. Influence of meditation on anti-correlated networks in the brain

    PubMed Central

    Josipovic, Zoran; Dinstein, Ilan; Weber, Jochen; Heeger, David J.

    2012-01-01

    Human experiences can be broadly divided into those that are external and related to interaction with the environment, and experiences that are internal and self-related. The cerebral cortex appears to be divided into two corresponding systems: an “extrinsic” system composed of brain areas that respond more to external stimuli and tasks and an “intrinsic” system composed of brain areas that respond less to external stimuli and tasks. These two broad brain systems seem to compete with each other, such that their activity levels over time is usually anti-correlated, even when subjects are “at rest” and not performing any task. This study used meditation as an experimental manipulation to test whether this competition (anti-correlation) can be modulated by cognitive strategy. Participants either fixated without meditation (fixation), or engaged in non-dual awareness (NDA) or focused attention (FA) meditations. We computed inter-area correlations (“functional connectivity”) between pairs of brain regions within each system, and between the entire extrinsic and intrinsic systems. Anti-correlation between extrinsic vs. intrinsic systems was stronger during FA meditation and weaker during NDA meditation in comparison to fixation (without mediation). However, correlation between areas within each system did not change across conditions. These results suggest that the anti-correlation found between extrinsic and intrinsic systems is not an immutable property of brain organization and that practicing different forms of meditation can modulate this gross functional organization in profoundly different ways. PMID:22287947

  14. Distraction for proximal interphalangeal joint contractures: long-term results.

    PubMed

    Houshian, Shirzad; Jing, Shan Shan; Kazemian, Gholam Hussein; Emami-Moghaddam-Tehrani, Mohammad

    2013-10-01

    To report the medium- to long-term outcomes of joint distraction using a unilateral external fixator in the treatment of chronic post-traumatic proximal interphalangaeal (PIP) joint contractures. Between September 2001 and October 2011, 94 consecutive patients (98 PIP joints) with a mean age of 43 years (range, 17-69 y) were treated with external fixation for chronic flexion deformity of the PIP joint from trauma. The average time from injury to surgery was 48 months (range, 6-84 mo), and the duration of joint distraction was 10 days (range, 7-22 d). Patients were followed for a mean period of 54 months (range, 12-72 mo). The average gain in joint flexion was 25° and in joint extension was 40°. The mean improvement in the active range of movement was 67° (range. 30°-90°). There was no loss of motion on the latest follow-up. Patients younger than 40 years fared slightly better than those older than 40 years. Two patients developed swelling, pain, and erythema during treatment, which resolved upon temporarily stopping the distraction process. There were 12 cases of superficial pin-site infections, which were managed conservatively without serious complications or adverse outcome. External fixation is a simple and effective treatment modality for chronic traumatic PIP joint contractures with good predictable medium- to long-term results. Careful patient selection and monitoring are required. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Limb saving surgery for Ewing's sarcoma of the distal tibia: a case report.

    PubMed

    Mizoshiri, Naoki; Shirai, Toshiharu; Terauchi, Ryu; Tsuchida, Shinji; Mori, Yuki; Katsuyama, Yusei; Hayashi, Daichi; Oka, Yoshinobu; Kubo, Toshikazu

    2018-05-02

    Ewing's sarcoma is a primary malignant tumor of bone occurring mostly in childhood. Few effective reconstruction techniques are available after wide resection of Ewing's sarcoma at the distal end of the tibia. Reconstruction after wide resection is especially difficult in children, as it is necessary to consider the growth and activity of the lower limbs. A 12-year-old Japanese boy had presented with right lower leg pain at age 8 years. Imaging examination showed a bone tumor accompanied by a large extra-skeletal mass in the distal part of his tibia. The tumor was histologically diagnosed as Ewing's sarcoma. The patient received chemotherapy, followed by wide resection. Reconstruction consisted of a bone transport method involving external fixation of Taylor Spatial Frame. To prevent infection after surgery, the external fixation pin was coated with iodine. One year after surgery, the patient showed poor consolidation of bone, so iliac bone transplantation was performed on the extended bones and docking site of the distal tibia. After 20 months, tibia formation was good. Three years after surgery, there was no evidence of tumor recurrence or metastases; bone fusion was good, and he was able to run. The bone transport method is an effective surgical method of reconstruction after wide resection of a bone tumor at the distal end of the tibia, if a pin can be inserted into the distal bone fragment. Coating external fixation pins with iodine may prevent postoperative infection.

  16. Semi-automated intra-operative fluoroscopy guidance for osteotomy and external-fixator.

    PubMed

    Lin, Hong; Samchukov, Mikhail L; Birch, John G; Cherkashin, Alexander

    2006-01-01

    This paper outlines a semi-automated intra-operative fluoroscopy guidance and monitoring approach for osteotomy and external-fixator application in orthopedic surgery. Intra-operative Guidance module is one component of the "LegPerfect Suite" developed for assisting the surgical correction of lower extremity angular deformity. The Intra-operative Guidance module utilizes information from the preoperative surgical planning module as a guideline to overlay (register) its bone outline semi-automatically with the bone edge from the real-time fluoroscopic C-Arm X-Ray image in the operating room. In the registration process, scaling factor is obtained automatically through matching a fiducial template in the fluoroscopic image and a marker in the module. A triangle metal plate, placed on the operating table is used as fiducial template. The area of template image within the viewing area of the fluoroscopy machine is obtained by the image processing techniques such as edge detection and Hough transformation to extract the template from other objects in the fluoroscopy image. The area of fiducial template from fluoroscopic image is then compared with the area of the marker from the planning so as to obtain the scaling factor. After the scaling factor is obtained, the user can use simple operations by mouse to shift and rotate the preoperative planning to overlay the bone outline from planning with the bone edge from fluoroscopy image. In this way osteotomy levels and external fixator positioning on the limb can guided by the computerized preoperative plan.

  17. Use of hinged transarticular external fixation for adjunctive joint stabilization in dogs and cats: 14 cases (1999-2003).

    PubMed

    Jaeger, Gayle H; Wosar, Marc A; Marcellin-Little, Denis J; Lascelles, B Duncan X

    2005-08-15

    To describe placement of hinged transarticular external fixation (HTEF) frames and evaluate their ability to protect the primary repair of unstable joints while allowing joint mobility in dogs and cats. Retrospective study. 8 cats and 6 dogs. HTEF frames were composed of metal or epoxy connecting rods and a hinge. Measurements of range of motion of affected and contralateral joints and radiographs were made after fixator application and removal. 9 animals (4 cats and 5 dogs) had tarsal and 5 (4 cats and 1 dog) had stifle joint injuries. Treatment duration ranged from 45 to 100 days (median, 57 days). Ranges of motion in affected stifle and tarsal joints were 57% and 72% of control while HTEF was in place and 79% and 84% of control after frame removal. Complications were encountered in 3 cats and 2 dogs and included breakage of pins and connecting rods, hinge loosening, and failure at the hinge-epoxy interface. HTEF in animals with traumatic joint instability provided adjunctive joint stabilization during healing and protection of the primary repair and maintained joint motion during healing, resulting in early weight bearing of the affected limb.

  18. The Muslim Headscarf and Face Perception: “They All Look the Same, Don't They?”

    PubMed Central

    Toseeb, Umar; Bryant, Eleanor J.; Keeble, David R. T.

    2014-01-01

    The headscarf conceals hair and other external features of a head (such as the ears). It therefore may have implications for the way in which such faces are perceived. Images of faces with hair (H) or alternatively, covered by a headscarf (HS) were used in three experiments. In Experiment 1 participants saw both H and HS faces in a yes/no recognition task in which the external features either remained the same between learning and test (Same) or switched (Switch). Performance was similar for H and HS faces in both the Same and Switch condition, but in the Switch condition it dropped substantially compared to the Same condition. This implies that the mere presence of the headscarf does not reduce performance, rather, the change between the type of external feature (hair or headscarf) causes the drop in performance. In Experiment 2, which used eye-tracking methodology, it was found that almost all fixations were to internal regions, and that there was no difference in the proportion of fixations to external features between the Same and Switch conditions, implying that the headscarf influenced processing by virtue of extrafoveal viewing. In Experiment 3, similarity ratings of the internal features of pairs of HS faces were higher than pairs of H faces, confirming that the internal and external features of a face are perceived as a whole rather than as separate components. PMID:24520313

  19. Knee arthrodesis using a short locked intramedullary nail. A new technique.

    PubMed

    Cheng, S L; Gross, A E

    1995-01-01

    This article reports on the use of a new intramedullary nail designed specifically for fixation of knee fusions. The nail is a short locked stainless steel nail that is inserted through a single anterior knee incision and uses an outrigger targeting rod to guide the insertion of the locking screws. The successful use of this technique is illustrated in two cases. The advantages of this nail compared with previously reported techniques of fixation for knee fusions are that the short locked nail avoids the second incision required for the insertion of long knee fusion nails, the bulkiness of the double plating technique in the relatively subcutaneous anterior knee area, and the difficulties inherent with the prolonged use of pins for external fixation.

  20. Knee arthrodesis.

    PubMed

    MacDonald, James H; Agarwal, Sanjeev; Lorei, Matthew P; Johanson, Norman A; Freiberg, Andrew A

    2006-03-01

    Arthrodesis is one of the last options available to obtain a stable, painless knee in a patient with a damaged knee joint that is not amenable to reconstructive measures. Common indications for knee arthrodesis include failed total knee arthroplasty, periarticular tumor, posttraumatic arthritis, and chronic sepsis. The primary contraindications to knee fusion are bilateral involvement or an ipsilateral hip arthrodesis. A variety of techniques has been described, including external fixation, internal fixation by compression plates, intramedullary fixation through the knee with a modular nail, and antegrade nailing through the piriformis fossa. Allograft or autograft may be necessary to restore lost bone stock or to augment fusion. For the carefully selected patient with realistic expectations, knee arthrodesis may relieve pain and obviate the need for additional surgery or extensive postoperative rehabilitation.

  1. Management of Late Onset Perthes: Evaluation of Distraction by External Fixator—5-Year Follow-Up

    PubMed Central

    Srivastava, Rajeshwar N.; Shukla, Prashant; Pushkar, Amit; Ali, Sabir

    2014-01-01

    Background. Hip distraction in Perthes' disease unloads the joint, which negates the harmful effect of the stresses on the articular surfaces, which may promote the sound healing of the area of necrosis. We have examined the effect of arthrodiastasis on the preservation of the femoral head in older children with Perthes' disease. Methods and Materials. Twelve children with age more than 8 years with Perthes' disease of less than one year were treated with hip distraction by a hinged monolateral external fixator. Observation and Results. Mean duration of distraction was 13.9 days. These children were evaluated by clinicoradiological parameters for a mean period of 32.4 months. There was a significant improvement in the range of movements and mean epiphyseal index, but the change in the percentage of uncovered head femur was insignificant. There was significant improvement in Harris Hip score. Conclusions. Hip distraction by hinged monolateral external fixator seems to be a valid treatment option in cases with Perthes' disease in the selected group of patients, where poor results are expected from conventional treatment. PMID:25580302

  2. Treatment outcomes of open pelvic fractures associated with extensive perineal injuries.

    PubMed

    Hasankhani, Ebrahim Ghayem; Omidi-Kashani, Farzad

    2013-12-01

    The main causes of death in patients with open pelviperineal injuries are uncontrollable bleeding and pelvic sepsis. The aim of this study was to evaluate the management outcomes of open pelvic fractures associated with extensive perineal injuries. We retrospectively studied 15 cases with open pelvic fractures associated with extensive perineal injuries (urethral and anal canal laceration) admitted between August 2006 and September 2010. Mechanism of injury, Injury Severity Score, associated injuries, hemodynamic status on arrival, resuscitation and transfusion requirements, operative techniques, intra- and postoperative complications, length of intensive care unit and hospital stay, and mortality were recorded in a computerised database for further evaluation and analysis. The male to female ratio was 12:3 with an average age of 38.6 years (ranged, 11 to 65 years). The average packed red blood cell units used were 8 units (ranged, 4 to 21 units). All patients were initially transferred to the operating room for colostomy, radical debridement and fixation of the pelvic fracture by an external fixator. One patient had acute renal failure, which improved with medical treatment and 2 patients (13.3%) died, one with type III anteroposterior compression fracture due to hemorrhagic shock and the other due to septicemia. Open pelvic fractures with extensive perineal injuries are associated with high mortality rates. Early diagnosis and appropriate treatment, including reanimation, colostomy, cystostomy, vigorous and repeated irrigation and debridement, and fixation by an external fixator can improve the outcomes and reduce the mortality rate.

  3. New fixation method for maxillary distraction osteogenesis using locking attachments.

    PubMed

    Suzuki, Eduardo Yugo; Buranastidporn, Boonsiva; Ishii, Masatoshi

    2006-10-01

    The external traction hooks of the intraoral splint used in the rigid external distraction (RED) system for maxillary distraction osteogenesis interfere with the surgical procedures. The purpose of this study is to introduce an innovative splint fixation method for maxillary distraction osteogenesis with Locking Attachments and evaluate their advantages, such as reduction of operating time compared with the traditional intraoral splint method. Retrospective comparison of operative times of maxillary Le Fort I osteotomy procedures was carried out with the traditional protocol using the intraoral splint cemented to the maxillary dentition (n = 14), and a removable intraoral splint that is inserted postsurgically (n = 14). Operative procedure times were compared and analyzed statistically using the data extracted from the surgical records. There were no complications inserting the removable splint postsurgically, including pain, discomfort, or time-consuming procedure. Stable and secure splint fixation was obtained before the distraction procedure and the desired treatment goals were obtained in all patients. The total operative procedure times were significantly reduced in the Locking Attachments group by 24% to 41% (approximately 65 minutes) compared with earlier operations involving the conventional splints (P < .05). Maxillary distraction osteogenesis with the Locking Attachments is a highly effective fixation approach to manage severe hypoplastic maxilla, eliminating lip constraints resulting from scarring and allowing for easier, more deliberate and careful dissection. The use of the Locking Attachments is reliable in craniofacial surgery and has proved to be advantageous in the reduction of the operating time and surgical risks.

  4. Biomechanical influence of pin placement and elbow angle on joint distraction and hinge alignment for an arthrodiatasis elbow-pin-fixator construct.

    PubMed

    Lee, Wei-Shiun; Linz, Shang-Chih; Shih, Kao-Shang; Chao, Ching-Kong; Chen, Yeung-Jen; Fan, Chang-Yuan

    2012-10-01

    Stiffness and contracture of the periarticular tissues are common complications of a post-traumatic elbow. Arthrodiatasis is a surgical technique that uses an external fixator for initial immobilization and subsequent distraction. The two prerequisites for an ideal arthrodiatasis are concentric distraction (avoiding bony contact) and hinge alignment (reducing internal stress). This study used the finite element (FE) method to clarify the relationship between these two prerequisites and the initial conditions (pin placement, elbow angle, and distraction mode). A total of 12 variations of the initial conditions were symmetrically arranged to evaluate their biomechanical influence on concentric distraction and hinge alignment. The humeroulnar surface was hypothesized to be ideally distracted orthogonal to the line joining the tips of the olecranon and the coronoid. The eccentric separation of the humeroulnar surfaces is a response to the non-orthogonality of the distracting force and joining line. Pin placement significantly affects the effective moment arm of the fixing pins to distract the bridged elbow. Both elbow angle and distraction mode directly alter the direction of the distracting force at the elbow center. In general, the hinges misalignment occurs in a direction opposite to the distraction-activated site. After joint distraction, the elastic deflection of the fixing pins inevitably makes both elbow and fixator hinges to misalign. This indicates that both joint distraction and hinge alignment are the interactive mechanisms. The humeroulnar separation is more concentric in the situation of the 120 degrees humeral distraction by using stiffer pins with convergent placement. Even so, the eccentric displacement of the elbow hinge is a crucial consideration in the initial placement of the guiding pin to compensate for hinge misalignment.

  5. The impact of zoledronic acid on regenerate and native bone after consolidation and removal of the external fixator: an animal model study.

    PubMed

    Saghieh, Said; Khoury, Nabil J; Tawil, Ayman; Masrouha, Karim Z; Musallam, Khaled M; Khalaf, Kinda; Dosh, Laura; Jaouhari, Rosemarie Reich; Birjawi, Ghina; El-Hajj-Fuleihan, Ghada

    2010-02-01

    We investigated the role of zoledronic acid on the regenerate and native bone after consolidation and removal of the external fixator in a rabbit model of distraction osteogenesis using 28 New Zealand white rabbits. The rabbits were randomly distributed into two groups. The first group received three doses of zoledronic acid (ZA) 0.1 mg/kg subcutaneously at weekly intervals while the second group received injections of sterile saline. Distraction started on day 7 at a rate of 0.8 mm/day for 12 days. At week 3 the average lengthening, regenerate density, and regenerate continuity were comparable between the two groups. At week 11 the regenerate in the treated group had a significant increase in Bone Mineral Density (BMD) and Bone Mineral Content (BMC) compared to the placebo group. On axial compression, the regenerate showed an increase in the peak load and a higher modulus of elasticity in the treated group. At 6 months, radiographs demonstrated signs of osteopenia of the proximal metaphysis in the control group, and failure of new bone formation around the pin sites in the treated group. BMC and BMD value differences between the two groups were not statistically significant. Histologically, there was persistence of more bone trabeculae in the medullary canal of the regenerate with the persistence of the pin-holes in the treated group. Mechanically, the regenerates in the treated group remain stronger in resisting the axial compression. The proximal fragment in the treated group exhibited a statistically significant decrease in the peak load, toughness and efail %. In conclusion, bisphosphonate-treated rabbits have a stronger regenerate during distraction, and directly after removal of the fixator. They do not develop disuse osteopenia in their lengthened tibia. This treatment may shorten the time in the external fixator and prevent fragility fractures in the treated extremity. However, its long-term safety has not yet been established. (c) 2009 Elsevier Inc. All rights reserved.

  6. Combined Internal and External Fixation for Diabetic Charcot Reconstruction: A Retrospective Case Series.

    PubMed

    Hegewald, Kenneth W; Wilder, Megan L; Chappell, Todd M; Hutchinson, Byron L

    2016-01-01

    Diabetic Charcot neuroarthropathy is a complex, limb-threatening disease process with major lifestyle-altering repercussions for patients. When Charcot neuroarthropathy leads to unstable deformity, ulceration, and potential infection despite conservative therapies, foot and ankle surgeons often consider reconstructive limb salvage procedures to restore function. The purpose of the present study was to evaluate the clinical and radiographic outcomes of diabetic Charcot reconstruction using combined internal and external fixation. A total of 22 patients were reviewed; 16 (72.73%) midfoot and 6 (27.27%) tibiotalocalcaneal arthrodesis procedures were consecutively performed from March 2009 to May 2013. All surgical procedures were performed in nonacute phases of the Charcot process in patients with diagnosed diabetes mellitus and documented peripheral neuropathy. Patients were excluded from the study if they were not diabetic despite having undergone Charcot reconstruction, regardless of the fixation method, or if they did not complete radiographic imaging. During a mean follow-up period of 58.60 ± 42.37 (range 16 to 164) weeks, limb salvage was achieved in 20 patients (90.91%), and 2 (9.09%) required below-the-knee amputation at a mean of 42 ± 14.14 weeks. Wound dehiscence occurred in 8 (36.36%), pin tract infection in 10 (45.45%), and superficial wound infection in 9 (40.91%) and peaked in bimodal fashion at 4 and 8 weeks postoperatively. Radiographic analysis of the pre- versus postoperative alignment showed statistically significant changes in the lateral talo-first metatarsal angle (p = .02) and lateral talar declination angle (p = .01). The limb salvage rates with diabetic Charcot reconstruction are improving in part because of the continued development of increasingly superior modalities for both internal and external fixation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. [Analysis of the results of bone healing in femurs lengthened by the gradual distraction method in children and adolescents].

    PubMed

    Jochymek, J; Skvaril, J; Ondrus, S

    2009-10-01

    Treatment of leg length inequality via lengthening of the shorter extremity is an infrequent orthopedic procedure due to the requirement of special distraction devices and possible serious complications. Essential qualitative changes in operative technique development are associated with the name of G. A. Ilizarov, who paved the way for the autoregenerate gradual distraction method in the 1950s. In the years 1990 through 2007 a total of 67 patients underwent femur lengthening via gradual distraction using various types of external fixators at the Department of Pediatric Surgery, Orthopedics, and Traumatology, Faculty Hospital in Brno. The quality of bone healing was monitored and a number of parameters followed and statistically evaluated using regularly scheduled X-ray examinations. In 13 cases we had to remove the external fixator following the distraction phase, perform an osteosynthesis via a splint and fill the distraction gap via spongioplasty. The bone healing was satisfactory in the remaining 54 patients and the lengthened bone required no other fixation method. The analysis showed statistically significant deceleration in bone healing following distraction in female patients over 12 years of age, and in boys over 14 years of age. Lack of periosteal callus five weeks after surgery always signified serious problems in further healing. Severe complications were recorded in 11 cases during the distraction phase, and in 12 cases after the removal of the distraction apparatus. Our results fully correspond with the data and experience of others cited authors. In addition our study showed deceleration in bone healing in girls over 12 years and in boys over 14 years of age and serious problem in healing when is lack of periostal callus five weeks after surgery. The aim of this report was to present the results of our study of distraction gap bone healing using the gradual lengthening approach. Key words: leg lengthening, gradual distraction, external fixation, leg discrepancy, complication.

  8. A Biomechanical Comparison Of Pin Configurations Used For Percutaneous Pinning Of Distal Tibia Fractures In Children.

    PubMed

    Brantley, Justin; Majumdar, Aditi; Jobe, J Taylor; Kallur, Antony; Salas, Christina

    2016-01-01

    Percutaneous pin fixation is often used in conjunction with closed-reduction and cast immobilization to treat pediatric distal tibia fractures. The goal of this procedure is to maintain reduction and provide improved stabilization, in effort to facilitate a more anatomic union. We conducted a biomechanical study of the torsional and bending stability of three commonly used pin configurations in distal tibia fracture fixation. A transverse fracture was simulated at the metaphyseal/diaphyseal junction in 15 synthetic tibias. Each fracture was reduced and fixed with two Kirschner wires, arranged in one of three pin configurations: parallel, retrograde, medial to lateral pins entering at the medial malleolus distal to the fracture (group A); parallel, antegrade, medial to lateral pins entering at the medial diaphysis proximal to the fracture (group B); or a cross-pin configuration with one retrograde, medial to lateral pin entering the medial malleolus distal to the fracture and the second an antegrade, medial to lateral pin entering at the medial diaphysis proximal to the fracture (group C). Stability of each construct was assessed by resistance to torsion and bending. Resistance to external rotation stress was significantly higher in group A than group B (P = 0.044). Resistance to internal rotation stress was significantly higher in group C than group B (P = 0.003). There was no significant difference in torsional stiffness when comparing group A with group C. Under a medial-directed load, group B and C specimens were significantly stiffer than those in group A (28 N/mm and 24 N/mm vs. 14 N/mm for A; P = 0.001 and P = 0.009, respectively). None of the three pin configurations produced superior results with respect to all variables studied. Group A configuration provided the highest resistance to external rotation forces, which is the most clinically relevant variable under short-cast immobilization. Parallel, retrograde, medial to lateral pins entering at the medial malleolus provide the greatest resistance to external rotation of the foot while minimizing the potential for iatrogenic injury to soft tissue structures.

  9. Biomechanical evaluation of a new fixation device for the thoracic spine.

    PubMed

    Hongo, Michio; Ilharreborde, Brice; Gay, Ralph E; Zhao, Chunfeng; Zhao, Kristin D; Berglund, Lawrence J; Zobitz, Mark; An, Kai-Nan

    2009-08-01

    The technology used in surgery for spinal deformity has progressed rapidly in recent years. Commonly used fixation techniques may include monofilament wires, sublaminar wires and cables, and pedicle screws. Unfortunately, neurological complications can occur with all of these, compromising the patients' health and quality of life. Recently, an alternative fixation technique using a metal clamp and polyester belt was developed to replace hooks and sublaminar wiring in scoliosis surgery. The goal of this study was to compare the pull-out strength of this new construct with sublaminar wiring, laminar hooks and pedicle screws. Forty thoracic vertebrae from five fresh frozen human thoracic spines (T5-12) were divided into five groups (8 per group), such that BMD values, pedicle diameter, and vertebral levels were equally distributed. They were then potted in polymethylmethacrylate and anchored with metal screws and polyethylene bands. One of five fixation methods was applied to the right side of the vertebra in each group: Pedicle screw, sublaminar belt with clamp, figure-8 belt with clamp, sublaminar wire, or laminar hook. Pull-out strength was then assessed using a custom jig in a servohydraulic tester. The mean failure load of the pedicle screw group was significantly larger than that of the figure-8 clamp (P = 0.001), sublaminar belt (0.0172), and sublaminar wire groups (P = 0.04) with no significant difference in pull-out strength between the latter three constructs. The most common mode of failure was the fracture of the pedicle. BMD was significantly correlated with failure load only in the figure-8 clamp and pedicle screw constructs. Only the pedicle screw had a statistically significant higher failure load than the sublaminar clamp. The sublaminar method of applying the belt and clamp device was superior to the figure-8 method. The sublaminar belt and clamp construct compared favorably to the traditional methods of sublaminar wires and laminar hooks, and should be considered as an alternative fixation device in the thoracic spine.

  10. Biomechanical evaluation of a new fixation device for the thoracic spine

    PubMed Central

    Hongo, Michio; Ilharreborde, Brice; Zhao, Chunfeng; Zhao, Kristin D.; Berglund, Lawrence J.; Zobitz, Mark; An, Kai-Nan

    2009-01-01

    The technology used in surgery for spinal deformity has progressed rapidly in recent years. Commonly used fixation techniques may include monofilament wires, sublaminar wires and cables, and pedicle screws. Unfortunately, neurological complications can occur with all of these, compromising the patients’ health and quality of life. Recently, an alternative fixation technique using a metal clamp and polyester belt was developed to replace hooks and sublaminar wiring in scoliosis surgery. The goal of this study was to compare the pull-out strength of this new construct with sublaminar wiring, laminar hooks and pedicle screws. Forty thoracic vertebrae from five fresh frozen human thoracic spines (T5–12) were divided into five groups (8 per group), such that BMD values, pedicle diameter, and vertebral levels were equally distributed. They were then potted in polymethylmethacrylate and anchored with metal screws and polyethylene bands. One of five fixation methods was applied to the right side of the vertebra in each group: Pedicle screw, sublaminar belt with clamp, figure-8 belt with clamp, sublaminar wire, or laminar hook. Pull-out strength was then assessed using a custom jig in a servohydraulic tester. The mean failure load of the pedicle screw group was significantly larger than that of the figure-8 clamp (P = 0.001), sublaminar belt (0.0172), and sublaminar wire groups (P = 0.04) with no significant difference in pull-out strength between the latter three constructs. The most common mode of failure was the fracture of the pedicle. BMD was significantly correlated with failure load only in the figure-8 clamp and pedicle screw constructs. Only the pedicle screw had a statistically significant higher failure load than the sublaminar clamp. The sublaminar method of applying the belt and clamp device was superior to the figure-8 method. The sublaminar belt and clamp construct compared favorably to the traditional methods of sublaminar wires and laminar hooks, and should be considered as an alternative fixation device in the thoracic spine. PMID:19404687

  11. Biomechanical validation of load-sharing rip-stop fixation for the repair of tissue-deficient rotator cuff tears.

    PubMed

    Burkhart, Stephen S; Denard, Patrick J; Konicek, John; Hanypsiak, Bryan T

    2014-02-01

    Poor-quality tendon is one of the most difficult problems the surgeon must overcome in achieving secure fixation during rotator cuff repair. A load-sharing rip-stop construct (LSRS) has recently been proposed as a method for improving fixation strength, but the biomechanical properties of this construct have not yet been examined. To compare the strength of the LSRS construct to that of single-row fixation for rotator cuff repair. Controlled laboratory study. Rotator cuff tears were created in 6 cadaveric matched-pair specimens and repaired with a single row or an LSRS. In the LSRS repair, a 2-mm suture tape was placed as an inverted mattress stitch in the rotator cuff, and sutures from 2 anchors were placed as simple stitches that passed medial to the suture tape. The suture tape limbs were secured with knotless anchors laterally before sutures were tied from the medial anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 371 ± 102 N in single-row repairs compared with 616 ± 185 N in LSRS repairs (P = .031). There was no difference in displacement with cyclic loading between the groups (3.3 ± 0.8 mm vs. 3.5 ± 1.1 mm; P = .561). In the single-row group, 4 of 6 failures occurred at the suture-tendon interface. In the LSRS group, only 1 failure occurred at the suture-tendon interface. The ultimate failure load of the LSRS construct for rotator cuff repair was 1.7 times that of a single-row construct in a cadaveric model. The LSRS rotator cuff repair construct may be useful in the repair of difficult tears such as massive tears, medial tears, and tears with tendon loss.

  12. Stabilizing potential of anterior, posterior, and circumferential fixation for multilevel cervical arthrodesis: an in vitro human cadaveric study of the operative and adjacent segment kinematics.

    PubMed

    Dmitriev, Anton E; Kuklo, Timothy R; Lehman, Ronald A; Rosner, Michael K

    2007-03-15

    This is an in vitro biomechanical study. The current investigation was performed to evaluate the stabilizing potential of anterior, posterior, and circumferential cervical fixation on operative and adjacent segment motion following 2 and 3-level reconstructions. Previous studies reported increases in adjacent level range of motion (ROM) and intradiscal pressure following single-level cervical arthrodesis; however, no studies have compared adjacent level effects following multilevel anterior versus posterior reconstructions. Ten human cadaveric cervical spines were biomechanically tested using an unconstrained spine simulator under axial rotation, flexion-extension, and lateral bending loading. After intact analysis, all specimens were sequentially instrumented from C3 to C5 with: (1) lateral mass fixation, (2) anterior cervical plate with interbody cages, and (3) combined anterior and posterior fixation. Following biomechanical analysis of 2-level constructs, fixation was extended to C6 and testing repeated. Full ROM was monitored at the operative and adjacent levels, and data normalized to the intact (100%). All reconstructive methods reduced operative level ROM relative to intact specimens under all loading methods (P < 0.05). However, circumferential fixation provided the greatest segmental stability among 2 and 3-level constructs (P < 0.05). Moreover, anterior cervical plate fixation was least efficient at stabilizing operative segments following C3-C6 arthrodesis (P < 0.05). Supradjacent ROM was increased for all treatment groups compared to normal data during flexion-extension testing (P < 0.05). Similar trends were observed under axial rotation and lateral bending loading. At the distal level, flexion-extension and axial rotation testing revealed comparable intergroup differences (P < 0.05), while lateral bending loading indicated greater ROM following 2-level circumferential fixation (P < 0.05). Results from our study revealed greater adjacent level motion following all 3 fixation types. No consistent significant intergroup differences in neighboring segment kinematics were detected among reconstructions. Circumferential fixation provided the greatest level of segmental stability without additional significant increase in adjacent level ROM.

  13. Internal rib structure can be predicted using mathematical models: An anatomic study comparing the chest to a shell dome with application to understanding fractures.

    PubMed

    Casha, Aaron R; Camilleri, Liberato; Manché, Alexander; Gatt, Ruben; Attard, Daphne; Gauci, Marilyn; Camilleri-Podesta, Marie-Therese; Mcdonald, Stuart; Grima, Joseph N

    2015-11-01

    The human rib cage resembles a masonry dome in shape. Masonry domes have a particular construction that mimics stress distribution. Rib cortical thickness and bone density were analyzed to determine whether the morphology of the rib cage is sufficiently similar to a shell dome for internal rib structure to be predicted mathematically. A finite element analysis (FEA) simulation was used to measure stresses on the internal and external surfaces of a chest-shaped dome. Inner and outer rib cortical thickness and bone density were measured in the mid-axillary lines of seven cadaveric rib cages using computerized tomography scanning. Paired t tests and Pearson correlation were used to relate cortical thickness and bone density to stress. FEA modeling showed that the stress was 82% higher on the internal than the external surface, with a gradual decrease in internal and external wall stresses from the base to the apex. The inner cortex was more radio-dense, P < 0.001, and thicker, P < 0.001, than the outer cortex. Inner cortical thickness was related to internal stress, r = 0.94, P < 0.001, inner cortical bone density to internal stress, r = 0.87, P = 0.003, and outer cortical thickness to external stress, r = 0.65, P = 0.035. Mathematical models were developed relating internal and external cortical thicknesses and bone densities to rib level. The internal anatomical features of ribs, including the inner and outer cortical thicknesses and bone densities, are similar to the stress distribution in dome-shaped structures modeled using FEA computer simulations of a thick-walled dome pressure vessel. Fixation of rib fractures should include the stronger internal cortex. © 2015 Wiley Periodicals, Inc.

  14. Repair of Tibiotarsal Rotation in 7 Chukar Partridges (Alectoris chukar) and 12 Domestic Pigeons (Columba livia domestica) with Type-2 External Skeletal Fixator Intramedullary Pin Tie-in.

    PubMed

    Kaya, Didar Aydin; Özsoy, Serhat

    2017-09-01

    Rotational deformities of the long bones affect various avian species. Tibiotarsal rotation may cause the leg to deviate up to 180° from the dorsoplantar axis in a matter of days, thus preventing the birds from walking freely and leading to the inability to stand. In this study, tibiotarsal rotation observed in pigeons and partridges was managed by creating a closed fracture in the tibiotarsus and then, following reduction, stabilizing it with an intramedullary tie-in Type 2 external skeletal fixation system. Functional healing was achieved in 12 pigeons (Columba livia domestica; mean healing time, 38 days) and 7 partridges (Alectoris chukar; mean healing time, 40 days). This treatment was successful. In small bird species (<1 kg), this simple and inexpensive surgical intervention may provide a highly effective method for the treatment of rotational deformities.

  15. Bilateral humeral lengthening in achondroplasia with unilateral external fixators: is it safe and does it improve daily life?

    PubMed

    Balci, H I; Kocaoglu, M; Sen, C; Eralp, L; Batibay, S G; Bilsel, K

    2015-11-01

    A retrospective study was performed in 18 patients with achondroplasia, who underwent bilateral humeral lengthening between 2001 and 2013, using monorail external fixators. The mean age was ten years (six to 15) and the mean follow-up was 40 months (12 to 104). The mean disabilities of the arm, shoulder and hand (DASH) score fell from 32.3 (20 to 40) pre-operatively to 9.4 (6 to 14) post-operatively (p = 0.037). A mean lengthening of 60% (40% to 95%) was required to reach the goal of independent perineal hygiene. One patient developed early consolidation, and fractures occurred in the regenerate bone of four humeri in three patients. There were three transient radial nerve palsies. Humeral lengthening increases the independence of people with achondroplasia and is not just a cosmetic procedure. ©2015 The British Editorial Society of Bone & Joint Surgery.

  16. Ankle Distraction Arthroplasty: Indications, Technique, and Outcomes.

    PubMed

    Bernstein, Mitchell; Reidler, Jay; Fragomen, Austin; Rozbruch, S Robert

    2017-02-01

    Ankle distraction is an alternative to ankle arthrodesis or total ankle arthroplasty in younger patients with arthritis. Ankle distraction involves the use of external fixation to mechanically unload the ankle joint, which allows for stable, congruent range of motion in the setting of decreased mechanical loading, potentially promoting cartilage repair. Adjunct surgical procedures are frequently done to address lower-extremity malalignment, ankle equinus contractures, and impinging tibiotalar osteophytes. Patients can bear full weight during the treatment course. The distraction frame frequently uses a hinge, and patients are encouraged to do daily range-of-motion exercises. Although the initial goal of the procedure is to delay arthrodesis, many patients achieve lasting clinical benefits, obviating the need for total ankle arthroplasty or fusion. Complications associated with external fixation are common, and patients should be counseled that clinical improvements occur slowly and often are not achieved until at least 1 year after frame removal.

  17. A novel simple external fixation for securing silicone stent in patients with upper tracheal stenosis

    PubMed Central

    Lin, Xiaoxiao; Ye, Min; Li, Yuping

    2018-01-01

    Upper tracheal stenosis is considered as a potentially life-threatening condition. Silicone stenting is an attractive treatment option for patients with upper tracheal stenosis. However, its use has been compromised by a major complication, stent migration. In the report, we introduced a novel external fixation of silicone stent which only needed one puncture site and involved a silicon chip as an anchoring device. All equipment and materials including the silicon chip were available in routine bronchoscopy suite. The method had been successfully performed in three patients with upper tracheal stenosis at our institution. And the patients were monitored for over 20 months after the intervention, and no spontaneous stent migration occurred. Therefore, we believe this is a simple and reliable approach for improving the outcome of silicone stenting in patients with upper tracheal stenosis and should be introduced in clinical practice.

  18. Management of severe open ankle-foot trauma by a simple external fixation technique: an alternative during war and in resource-poor and low-technology environments.

    PubMed

    Pedrini, Gianpaolo; Cardi, Maurizio; Landini, Alberto; Strada, Gino

    2011-03-01

    Severe open foot and ankle injuries are still a challenge for the orthopaedic surgeon. Their treatment is even more difficult in third world countries and in war settings where high-energy trauma with severe soft tissue damage is more frequent. Lack of equipment, poor resources and hygiene, and different cultural systems make most of the standard proposed treatments difficult to apply. The authors describe an inexpensive, rapid, minimally invasive, and easy-to-apply external fixation technique for the treatment of severe open ankle-foot fractures. With the main goal of soft tissue management rather than definitive treatment of any bony injuries, this technique was developed over time during many consecutive missions in Sierra Leone and Afghanistan as an alternative to more appropriate treatments with surprisingly satisfactory short- and long-term results.

  19. Open tibial fractures grade IIIC treated successfully with external fixation, negative-pressure wound therapy and recombinant human bone morphogenetic protein 7.

    PubMed

    Babiak, Ireneusz

    2014-10-01

    The aim of the therapy in open tibial fractures grade III was to cover the bone with soft tissue and achieve healed fracture without persistent infection. Open tibial fractures grade IIIC with massive soft tissue damage require combined orthopaedic, vascular and plastic-reconstructive procedures. Negative-pressure wound therapy (NPWT), used in two consecutive cases with open fracture grade IIIC of the tibia diaphysis, healed extensive soft tissue defect with exposure of the bone. NPWT eventually allowed for wound closure by split skin graft within 21-25 days. Ilizarov external fixator combined with application of recombinant human bone morphogenetic protein-7 at the site of delayed union enhanced definitive bone healing within 16-18 months. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  20. Three-dimensional evaluation of cyclic displacement in single-row and double-row rotator cuff reconstructions under static external rotation.

    PubMed

    Lorbach, Olaf; Kieb, Matthias; Raber, Florian; Busch, Lüder C; Kohn, Dieter M; Pape, Dietrich

    2013-01-01

    The double-row suture bridge repair was recently introduced and has demonstrated superior biomechanical results and higher yield load compared with the traditional double-row technique. It therefore seemed reasonable to compare this second generation of double-row constructs to the modified single-row double mattress reconstruction. The repair technique, initial tear size, and tendon subregion will have a significant effect on 3-dimensional (3D) cyclic displacement under additional static external rotation of a modified single-row compared with a double-row rotator cuff repair. Controlled laboratory study. Rotator cuff tears (small to medium: 25 mm; medium to large: 35 mm) were created in 24 human cadaveric shoulders. Rotator cuff repairs were performed as modified single-row or double-row repairs, and cyclic loading (10-60 N, 10-100 N) was applied under 20° of external rotation. Radiostereometric analysis was used to calculate cyclic displacement in the anteroposterior (x), craniocaudal (y), and mediolateral (z) planes with a focus on the repair constructs and the initial tear size. Moreover, differences in cyclic displacement of the anterior compared with the posterior tendon subregions were calculated. Significantly lower cyclic displacement was seen in small to medium tears for the single-row compared with double-row repair at 60 and 100 N in the x plane (P = .001) and y plane (P = .001). The results were similar in medium to large tears at 100 N in the x plane (P = .004). Comparison of 25-mm versus 35-mm tears did not show any statistically significant differences for the single-row repairs. In the double-row repairs, lower gap formation was found for the 35-mm tears (P ≤ .05). Comparison of the anterior versus posterior tendon subregions revealed a trend toward higher anterior gap formation, although this was statistically not significant. The tested single-row reconstruction achieved superior results in 3D cyclic displacement to the tested double-row repair. Extension of the initial rupture size did not have a negative effect on the biomechanical results of the tested constructs. Single-row repairs with modified suture configurations provide comparable biomechanical strength to double-row repairs. Furthermore, as increased gap formation in the early postoperative period might lead to failure of the construct, a strong anterior fixation and restricted external rotation protocol might be considered in rotator cuff repairs to avoid this problem.

  1. Finite element analysis of the three different posterior malleolus fixation strategies in relation to different fracture sizes.

    PubMed

    Anwar, Adeel; Lv, Decheng; Zhao, Zhi; Zhang, Zhen; Lu, Ming; Nazir, Muhammad Umar; Qasim, Wasim

    2017-04-01

    Appropriate fixation method for the posterior malleolar fractures (PMF) according to the fracture size is still not clear. Aim of this study was to evaluate the outcomes of the different fixation methods used for fixation of PMF by finite element analysis (FEA) and to compare the effect of fixation constructs on the size of the fracture computationally. Three dimensional model of the tibia was reconstructed from computed tomography (CT) images. PMF of 30%, 40% and 50% fragment sizes were simulated through computational processing. Two antero-posterior (AP) lag screws, two postero-anterior (PA) lag screws and posterior buttress plate were analysed for three different fracture volumes. The simulated loads of 350N and 700N were applied to the proximal tibial end. Models were fixed distally in all degrees of freedom. In single limb standing condition, the posterior plate group produced the lowest relative displacement (RD) among all the groups (0.01, 0.03 and 0.06mm). Further nodal analysis of the highest RD fracture group showed a higher mean displacement of 4.77mm and 4.23mm in AP and PA lag screws model (p=0.000). The amounts of stress subjected to these implants, 134.36MPa and 140.75MPa were also significantly lower (p=0.000). There was a negative correlation (p=0.021) between implant stress and the displacement which signifies a less stable fixation using AP and PA lag screws. Progressively increasing fracture size demands more stable fixation construct because RD increases significantly. Posterior buttress plate produces superior stability and lowest RD in PMF models irrespective of the fragment size. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?

    PubMed

    Shah, S; Kim, S Y R; Dubov, A; Schemitsch, E H; Bougherara, H; Zdero, R

    2011-09-01

    Femoral shaft fractures after total hip arthroplasty (THA) remain a serious problem, since there is no optimal surgical repair method. Virtually all studies that examined surgical repair methods have done so clinically or experimentally. The present study assessed injury patterns computationally by developing three-dimensional (3D) finite element (FE) models that were validated experimentally. The investigation evaluated three different constructs for the fixation of Vancouver B1 periprosthetic femoral shaft fractures following THA. Experimentally, three bone plate repair methods were applied to a synthetic femur with a 5 mm fracture gap near the tip of a total hip implant. Repair methods were identical distal to the fracture gap, but used cables only (construct A), screws only (construct B), or cables plus screws (construct C) proximal to the fracture gap. Specimens were oriented in 15 degrees adduction to simulate the single-legged stance phase of walking, subjected to 1000 N of axial force, and instrumented with strain gauges. Computationally, a linearly elastic and isotropic 3D FE model was developed to mimic experiments. Results showed excellent agreement between experimental and FE strains, yielding a Pearson linearity coefficient, R2, of 0.92 and a slope for the line of best data fit of 1.06. FE-computed axial stiffnesses were 768 N/mm (construct A), 1023 N/mm (construct B), and 1102 N/mm (construct C). FE surfaces stress maps for cortical bone showed Von Mises stresses, excluding peaks, of 0-8 MPa (construct A), 0-15 MPa (construct B), and 0-20 MPa (construct C). Cables absorbed the majority of load, followed by the plates and then the screws. Construct A yielded peak stress at one of the empty holes in the plate. Constructs B and C had similar bone stress patterns, and can achieve optimal fixation.

  3. Recent Developments in Ground-Borne Noise and Vibration Control

    NASA Astrophysics Data System (ADS)

    Nelson, J. T.

    1996-05-01

    Vibration control provisions available to the transit designer include (among others) precision straightened rail, ballast mats, floating slabs and very soft direct fixation fasteners, in addition to rail grinding, wheel truing, and continuous welded rail. Recently, the Los Angeles Metro has developed specifications for a soft resilient direct fixation fastener to fit the same base dimensions as the standard direct fixation fastener. In San Francisco, low resonance frequency (8 Hz) floating slabs have been constructed to mitigate predicted ground vibration impacts at nearby residential structures. In Atlanta, low resonance frequency loading slabs have been constructed to maintain a low vibration environment in a medical building planned to be built over the subway structure. In Portland and Pasadena, ballast mats have been recommended to control light rail transit ground vibration impacts on housing located at typically 35 feet from the alignment. Each of these provisions are briefly described in view of recent applications at U.S. transit systems.

  4. Fixation systems of greater trochanteric osteotomies: biomechanical and clinical outcomes.

    PubMed

    Jarit, Gregg J; Sathappan, Sathappan S; Panchal, Anand; Strauss, Eric; Di Cesare, Paul E

    2007-10-01

    The development of cerclage systems for fixation of greater trochanteric osteotomies has progressed from monofilament wires to multifilament cables to cable grip and cable plate systems. Cerclage wires and cables have various clinical indications, including fixation for fractures and for trochanteric osteotomy in hip arthroplasty. To achieve stable fixation and eventual union of the trochanteric osteotomy, the implant must counteract the destabilizing forces associated with pull of the peritrochanteric musculature. The material properties of cables and cable grip systems are superior to those of monofilament wires; however, potential complications with the use of cables include debris generation and third-body polyethylene wear. Nevertheless, the cable grip system provides the strongest fixation and results in lower rates of nonunion and trochanteric migration. Cable plate constructs show promise but require further clinical studies to validate their efficacy and safety.

  5. The Use of 3D Printing Technology in the Ilizarov Method Treatment: Pilot Study.

    PubMed

    Burzyńska, Karolina; Morasiewicz, Piotr; Filipiak, Jarosław

    2016-01-01

    Significant developments in additive manufacturing technology have occurred in recent years. 3D printing techniques can also be helpful in the Ilizarov method treatment. The aim of this study was to evaluate the usefulness of 3D printing technology in the Ilizarov method treatment. Physical models of bones used to plan the spatial design of Ilizarov external fixator were manufactured by FDM (Fused Deposition Modeling) spatial printing technology. Bone models were made of poly(L-lactide) (PLA). Printed 3D models of both lower leg bones allow doctors to prepare in advance for the Ilizarov method treatment: detailed consideration of the spatial configuration of the external fixation, experimental assembly of the Ilizarov external fixator onto the physical models of bones prior to surgery, planning individual osteotomy level and Kirschner wires introduction sites. Printed 3D bone models allow for accurate preparation of the Ilizarov apparatus spatially matched to the size of the bones and prospective bone distortion. Employment of the printed 3D models of bone will enable a more precise design of the apparatus, which is especially useful in multiplanar distortion and in the treatment of axis distortion and limb length discrepancy in young children. In the course of planning the use of physical models manufactured with additive technology, attention should be paid to certain technical aspects of model printing that have an impact on the accuracy of mapping of the geometry and physical properties of the model. 3D printing technique is very useful in 3D planning of the Ilizarov method treatment.

  6. Outcomes following femoral lengthening: An initial comparison of the Precice intramedullary lengthening nail and the LRS external fixator monorail system.

    PubMed

    Laubscher, M; Mitchell, C; Timms, A; Goodier, D; Calder, P

    2016-10-01

    Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages. We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared. In 20 cases (15 patients) the Precice lengthening nail was used and in 13 cases (seven patients) the LRS external fixator system. The desired length was achieved in all cases in the Precice group and in 12 of 13 cases in the LRS group. The mean healing index was 31.3 days/cm in the Precice and 47.1 days/cm in the LRS group (p < 0.001). This was associated with an earlier ability to bear full weight without aids in the Precice group. There were more complications with LRS lengthening, including pin site infections and regenerate deformity. Implant tolerance and the patients' perception of the cosmetic result were better with the Precice treatment. Femoral lengthening with the Precice femoral nail achieved excellent functional results with fewer complications and greater patient satisfaction when compared with the LRS system in our patients. Cite this article: Bone Joint J 2016;98-B:1382-8. ©2016 The British Editorial Society of Bone & Joint Surgery.

  7. Medial submuscular plating of the femur in a series of paediatric patients: a useful alternative to standard lateral techniques.

    PubMed

    Nayagam, S; Davis, B; Thevendran, G; Roche, A J

    2014-01-01

    We describe the technique and results of medial submuscular plating of the femur in paediatric patients and discuss its indications and limitations. Specifically, the technique is used as part of a plate-after-lengthening strategy, where the period of external fixation is reduced and the plate introduced by avoiding direct contact with the lateral entry wounds of the external fixator pins. The technique emphasises that vastus medialis is interposed between the plate and the vascular structures. A total of 16 patients (11 male and five female, mean age 9.6 years (5 to 17)), had medial submuscular plating of the femur. All underwent distraction osteogenesis of the femur with a mean lengthening of 4.99 cm (3.2 to 12) prior to plating. All patients achieved consolidation of the regenerate without deformity. The mean follow-up was 10.5 months (7 to 15) after plating for those with plates still in situ, and 16.3 months (1 to 39) for those who subsequently had their plates removed. None developed a deep infection. In two patients a proximal screw fractured without loss of alignment; one patient sustained a traumatic fracture six months after removal of the plate. Placing the plate on the medial side is advantageous when the external fixator is present on the lateral side, and is biomechanically optimal in the presence of a femoral defect. We conclude that medial femoral submuscular plating is a useful technique for specific indications and can be performed safely with a prior understanding of the regional anatomy.

  8. A prospective study of external stenting of saphenous vein grafts to the right coronary artery: the VEST II study.

    PubMed

    Taggart, David P; Amin, Sanaz; Djordjevic, Jasmina; Oikonomou, Evangelos K; Thomas, Sheena; Kampoli, Anna-Maria; Sabharwal, Nikant; Antoniades, Charalambos; Krasopoulos, George

    2017-05-01

    External stents significantly reduce intimal hyperplasia and improve lumen uniformity and flow pattern in saphenous vein grafts (SVG) 1 year after coronary artery bypass grafting. However, recent studies have shown that at 1 year there is a lower patency of externally stented SVG to the right coronary artery (RCA) (55-60%) when compared to the left sided coronary arteries (85-90%). In the current study, we investigated whether avoidance of both fixation of the external stent to the anastomoses and the use of metal clips to ligate SVG side branches would improve the early patency of externally stented SVG to the RCA. Thirty patients received a SVG to the right territory supported with an external stent. Graft patency was confirmed at the end of surgery in all patients. The primary endpoint was SVG patency assessed by computed tomography angiography (CTA) at 3-6 months. Graft failure was defined as > 50% stenosis. Twenty-nine patients (96.6%) completed the follow up period and CT angiography data was available for a total of 43 SVGs, (29 supported and 14 unsupported SVGs) and 47 arterial grafts. Patency of stented SVGs was 86.2% (25/29 on CTA). All non-stented SVGs to the left territory were patent. Patency rates of the left internal mammary arteries and right internal mammary arteries grafts were 96.6% and 83.3%, respectively. Avoidance of both metallic clips to ligate side branches and of fixation of venous external support trial (VEST) stents to the anastomoses mark a significant improvement in patency of stented SVG to the right coronary territory. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Fixation of osteochondral fractures in rabbit knees. A comparison of Kirschner wires, fibrin sealant, and polydioxanone pins.

    PubMed

    Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M

    1992-03-01

    We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.

  10. Intra-articular fractures of the distal tibia

    PubMed Central

    Sitnik, Alexandre; Beletsky, Aleksander; Schelkun, Steven

    2017-01-01

    Results of the treatment of intra-articular fractures of the distal tibia have improved significantly during the last two decades. Recognition of the role of soft tissues has led to the development of a staged treatment strategy. At the first stage, joint-bridging external fixation and fibular fixation are performed. This leads to partial reduction of the distal tibial fracture and allows time for the healing of soft tissues and detailed surgical planning. Definitive open reduction and internal fixation of the tibial fracture is performed at a second stage, when the condition of the soft tissues is safe. The preferred surgical approach(es) is chosen based on the fracture morphology as determined from standard radiographic views and computed tomography. Meticulous atraumatic soft-tissue handling and the use of modern fixation techniques for the metaphyseal component such as minimally invasive plate osteosynthesis further facilitate healing. Cite this article: EFORT Open Rev 2017;2:352-361. DOI: 10.1302/2058-5241.2.150047 PMID:28932487

  11. Management of recent unstable fractures of the pelvic ring. An update conference supported by the Club Bassin Cotyle. (Pelvis-Acetabulum Club).

    PubMed

    Tonetti, J

    2013-02-01

    Traumatic injury to the pelvic ring is a result of high energy trauma in young patients. These osteo-ligamentous injuries are associated with numerous lesions including retroperitoneal hematoma, urogenital, cutaneous and neurological (lumbosacral plexus). The goal of initial management is to restore vital indicators, urinary excretion function and protect the patient from infectious complications. An emergency decisional algorithm helps manage haemodynamic instability. Initial bone and ligament procedures should reduce displacement and make it possible for the patient the wait until his condition is stable enough for definitive surgical fixation. The goal of surgical treatment is to avoid nonunion and malunion. Stable fixation of the posterior arch after reduction favors union. Different techniques can be used by the posterior, anterior ilio-inguinal or lateral percutaneous approaches. Anterior fixation is discussed to improve reduction and increase the stability obtained with a posterior procedure. Anterior external fixation is useful to temporarily reinforce posterior stabilization. Copyright © 2013. Published by Elsevier Masson SAS.

  12. The cervical end of an occipitocervical fusion: a biomechanical evaluation of 3 constructs. Laboratory investigation.

    PubMed

    Finn, Michael A; Fassett, Daniel R; Mccall, Todd D; Clark, Randy; Dailey, Andrew T; Brodke, Darrel S

    2008-09-01

    Stabilization with rigid screw/rod fixation is the treatment of choice for craniocervical disorders requiring operative stabilization. The authors compare the relative immediate stiffness for occipital plate fixation in concordance with transarticular screw fixation (TASF), C-1 lateral mass and C-2 pars screw (C1L-C2P), and C-1 lateral mass and C-2 laminar screw (C1L-C2L) constructs, with and without a cross-link. Ten intact human cadaveric spines (Oc-C4) were prepared and mounted in a 7-axis spine simulator. Each specimen was precycled and then tested in the intact state for flexion/extension, lateral bending, and axial rotation. Motion was tracked using the OptoTRAK 3D tracking system. The specimens were then destabilized and instrumented with an occipital plate and TASF. The spine was tested with and without the addition of a cross-link. The C1L-C2P and C1L-C2L constructs were similarly tested. All constructs demonstrated a significant increase in stiffness after instrumentation. The C1L-C2P construct was equivalent to the TASF in all moments. The C1L-C2L was significantly weaker than the C1L-C2P construct in all moments and significantly weaker than the TASF in lateral bending. The addition of a cross-link made no difference in the stiffness of any construct. All constructs provide significant immediate stability in the destabilized occipitocervical junction. Although the C1L-C2P construct performed best overall, the TASF was similar, and either one can be recommended. Decreased stiffness of the C1L-C2L construct might affect the success of clinical fusion. This construct should be reserved for cases in which anatomy precludes the use of the other two.

  13. Do stand-alone interbody spacers with integrated screws provide adequate segmental stability for multilevel cervical arthrodesis?

    PubMed

    Paik, Haines; Kang, Daniel G; Lehman, Ronald A; Cardoso, Mario J; Gaume, Rachel E; Ambati, Divya V; Dmitriev, Anton E

    2014-08-01

    Some postoperative complications after anterior cervical fusions have been attributed to anterior cervical plate (ACP) profiles and the necessary wide operative exposure for their insertion. Consequently, low-profile stand-alone interbody spacers with integrated screws (SIS) have been developed. Although SIS constructs have demonstrated similar biomechanical stability to the ACP in single-level fusions, their role as a stand-alone device in multilevel reconstructions has not been thoroughly evaluated. To evaluate the acute segmental stability afforded by an SIS device compared with the traditional ACP in the setting of a multilevel cervical arthrodesis. In vitro human cadaveric biomechanical analysis. Thirteen human cadaveric cervical spines (C2-T1) were nondestructively tested with a custom 6 df spine simulator under axial rotation, flexion-extension, and lateral bending loading. After intact analysis, eight single-levels (C4-C5/C6-C7) from four specimens were instrumented and tested with ACP and SIS. Nine specimens were tested with C5-C7 SIS, C5-C7 ACP, C4-C7 ACP, C4-C7 ACP+posterior fixation, C4-C7 SIS, and C4-C7 SIS+posterior fixation. Testing order was randomized with each additional level instrumented. Full range of motion (ROM) data were obtained and analyzed by each loading modality, using mean comparisons with repeated measures analysis of variance. Paired t tests were used for post hoc analysis with Sidak correction for multiple comparisons. No significant difference in ROM was noted between the ACP and SIS for single-level fixation (p>.05). For multisegment reconstructions (two and three levels), the ACP proved superior to SIS and intact condition, with significantly lower ROM in all planes (p<.05). When either the three-level SIS or ACP constructs were supplemented with posterior lateral mass fixation, there was a greater than 80% reduction in ROM under all testing modalities (p<.05), with no significant difference between the ACP and SIS constructs (p>.05). The SIS device may be a reasonable option as a stand-alone device for single-level fixation. However, SIS devices should be used with careful consideration in the setting of multilevel cervical fusion. However, when supplemented with posterior fixation, SIS devices are a sound biomechanical alternative to ACP for multilevel fusion constructs. Published by Elsevier Inc.

  14. [Development and current situation of reconstruction methods following total sacrectomy].

    PubMed

    Huang, Siyi; Ji, Tao; Guo, Wei

    2018-05-01

    To review the development of the reconstruction methods following total sacrectomy, and to provide reference for finding a better reconstruction method following total sacrectomy. The case reports and biomechanical and finite element studies of reconstruction following total sacrectomy at home and abroad were searched. Development and current situation were summarized. After developing for nearly 30 years, great progress has been made in the reconstruction concept and fixation techniques. The fixation methods can be summarized as the following three strategies: spinopelvic fixation (SPF), posterior pelvic ring fixation (PPRF), and anterior spinal column fixation (ASCF). SPF has undergone technical progress from intrapelvic rod and hook constructs to pedicle and iliac screw-rod systems. PPRF and ASCF could improve the stability of the reconstruction system. Reconstruction following total sacrectomy remains a challenge. Reconstruction combining SPF, PPRF, and ASCF is the developmental direction to achieve mechanical stability. How to gain biological fixation to improve the long-term stability is an urgent problem to be solved.

  15. Extraocular surgery for implantation of an active subretinal visual prosthesis with external connections: feasibility and outcome in seven patients.

    PubMed

    Besch, D; Sachs, H; Szurman, P; Gülicher, D; Wilke, R; Reinert, S; Zrenner, E; Bartz-Schmidt, K U; Gekeler, F

    2008-10-01

    Due to low energy levels in microphotodiode-based subretinal visual prostheses, an external power supply is mandatory. We report on the surgical feasibility and the functional outcome of the extraocular part of an approach to connect a subretinal prosthesis to an extracorporeal connector in the retro-auricular space via a trans-scleral, transchoroidal cable. Seven volunteers with retinitis pigmentosa received an active subretinal implant; energy was supplied by gold wires on a trans-sclerally, transchoroidally implanted polyimide foil leading to the lateral orbital rim where it was fixated and connected to a silicone cable. The cable was implanted subperiostally beneath the temporal muscle using a trocar to the retro-auricular space where it penetrated the skin for connection to a stimulator. To avoid subretinal movement of the implant, three tension relief points have been introduced. All implantations were performed as planned without complications, and no serious adverse events occurred in the postoperative period. Fixation of the implants was stable throughout the entire study duration of 4 weeks; permanent skin penetration proved to be uncomplicated. Motility was minimally restricted in downgaze and ab-/adduction. Explantation was uneventful. The above-described procedure provides a method for stable fixation of a subretinal device with a trans-scleral, transchoroidal cable connection to an extracorporeal connector.

  16. Deliberate real-time mood regulation in adulthood: the importance of age, fixation and attentional functioning.

    PubMed

    Noh, Soo Rim; Lohani, Monika; Isaacowitz, Derek M

    2011-09-01

    While previous research has linked executive attention to emotion regulation, the current study investigated the role of attentional alerting (i.e., efficient use of external warning cues) on younger (N=39) and older (N=44) adults' use of gaze to regulate their mood in real time. Participants viewed highly arousing unpleasant images while reporting their mood and were instructed to deliberately manage how they felt and to minimise the effect of those stimuli on their mood. Fixations toward the most negative areas of the images were recorded with eye tracking. We examined whether looking less at the most negative regions, compared to each individual's own tendency, was a beneficial mood regulatory strategy and how it interacted with age and alerting ability. High alerting older adults, who rely more on external cues to guide their attention, experienced a smaller decline in mood over time by activating a less-negative-looking approach (compared to their own average tendency), effectively looking away from the most negative areas of the images. More negative gaze patterns predicted better mood for younger adults, though this effect decreased over time. Alerting did not moderate gaze-mood links in younger adults. Successful mood regulation may thus depend on particular combinations of age, fixation, and attention.

  17. Deliberate Real-time Mood Regulation in Adulthood: The Importance of Age, Fixation and Attentional Functioning

    PubMed Central

    Noh, Soo Rim; Lohani, Monika; Isaacowitz, Derek M.

    2011-01-01

    While previous research has linked executive attention to emotion regulation, the current study investigated the role of attentional alerting (i.e., efficient use of external warning cues) on younger (N = 39) and older (N = 44) adults’ use of gaze to regulate their mood in real time. Participants viewed highly arousing unpleasant images while reporting their mood and were instructed to deliberately manage how they felt and to minimize the effect of those stimuli on their mood. Fixations toward the most negative areas of the images were recorded with eye tracking. We examined whether looking less at the most negative regions, compared to each individual’s own tendency, was a beneficial mood regulatory strategy and how it interacted with age and alerting ability. High alerting older adults, who rely more on external cues to guide their attention, experienced a smaller decline in mood over time by activating a less-negative-looking approach (compared to their own average tendency), effectively looking away from the most negative areas of the images. More negative gaze patterns predicted better mood for younger adults, though this effect decreased over time. Alerting did not moderate gaze-mood links in younger adults. Successful mood regulation may thus depend on particular combinations of age, fixation, and attention. PMID:21432641

  18. Open unstable metaphyseo-diaphyseal fractures of the tibia in adolescents: treatment by flexible intramedullary nails augmented by external fixator.

    PubMed

    Atef, Ashraf; El Tantawy, Ahmad

    2015-05-01

    The treatment of open and unstable metaphyseo-diaphyseal fractures of the tibia in adolescents is challenging. It is important to choose a fixation method that can maintain alignment, allow wound care and not violate the growth plate. The aim of this work was to evaluate the efficacy of using flexible intramedullary nails (FIN) augmented by external fixator (EF) in the management of such fractures. A total of 26 males, with a mean age of 14.08 years and average body weight of 49.8 kg, presented with open metaphyseo-diaphyseal tibial fractures. All cases were treated using FIN augmented by mono-lateral EF. The fractures were located at the upper third in 17 cases and at the lower third in nine cases. The fracture pattern was spiral in eight cases, oblique in seven and multi-fragmentary in 11. The results were evaluated according to the scoring system for femoral TENs. All fractures united primarily after an average eight to 12 weeks with no evident angular deformity or limb-length discrepancy. None of the cases required cast immobilization or revision procedure. Twenty patients had excellent results, six patients showed good results and none had poor results. Fracture characteristics as well as patients' characteristics had no statistically significant effect (p > 0.005) on the final end results. The use of FIN augmented by EF is a good alternative in the management of open metaphyseo-diaphyseal tibial fractures in adolescents. This fixation provides more stability, allows easy access to the wound and early patients' ambulation.

  19. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

    PubMed

    Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien

    2011-09-01

    The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

  20. The use of circular external fixators in the management of lower limb trauma in Dublin: a single surgeon's 20-year experience.

    PubMed

    O'Neill, B J; Fox, C M; Molloy, A P; O'hEireamhoin, S; Moore, D P

    2016-02-01

    It has been estimated that approximately 520,000 injury presentations are made to Irish accident and emergency departments each year. Fractures account for 20 % of these injuries. Circular external fixators (frames) have been shown to be a safe and effective method of treatment for long bone fractures where internal fixation is impossible or in-advisable. We present the outcomes of all frames applied at our institution for stabilisation of acute fractures over a 20-year period. We retrospectively reviewed a prospectively compiled database of all frames applied in our institution and identified all frames which were applied for acute lower limb trauma. We identified 68 fractures in 63 patients. There were 11 femoral fractures and 57 tibial fractures. All fractures were classified using the AO Classification system, and most fractures were Type C fractures. We used an Ilizarov frame for 53 fractures and a Taylor Spatial Frame for 15 fractures. The mean time in frame was 365 days for a femoral fracture and 230 days for a tibial fracture. There were five tibial non-unions giving an overall union rate of 93 %. Factors associated with non-union included high-energy trauma and cigarette smoking. The vast majority of lower limb fractures can be treated using 'conventional' methods. Complex fractures which are not amenable to open reduction and internal fixation or cast immobilisation can be treated in a frame with excellent results. The paucity of published reports regarding the use of frames for complex trauma reflects the under-utilisation of the technique.

  1. Biomechanical analysis of intramedullary vs. superior plate fixation of transverse midshaft clavicle fractures.

    PubMed

    Wilson, David J; Scully, William F; Min, Kyong S; Harmon, Tess A; Eichinger, Josef K; Arrington, Edward D

    2016-06-01

    Middle-third clavicle fractures represent 2% to 4% of all skeletal trauma in the United States. Treatment options include intramedullary (IM) as well as plate and screw (PS) constructs. The purpose of this study was to analyze the biomechanical stability of a specific IM system compared with nonlocking PS fixation under low-threshold physiologic load. Twenty fourth-generation Sawbones (Pacific Research Laboratories, Vashon, WA, USA) with a simulated middle-third fracture pattern were repaired with either an IM device (n = 10) or superiorly positioned nonlocking PS construct (n = 10). Loads were modeled to simulate physiologic load. Combined axial compression and torsion forces were sequentially increased until failure. Data were analyzed on the basis of loss of rotational stability using 3 criteria: early (10°), clinical (30°), and terminal (120°). No significant difference was noted between constructs in early loss of rotational stability (P > .05). The PS group was significantly more rotationally stable than the IM group on the basis of clinical and terminal criteria (P < .05 for both). All test constructs failed in rotational stability. When tested under physiologic load, fixation failure occurred from loss of rotational stability. No statistical difference was seen between groups under early physiologic loads. However, during load to failure, the PS group was statistically more rotationally stable than the IM group. Given the clavicle's function as a bony strut for the upper extremity and the biomechanical results demonstrated, rotational stability should be carefully considered during surgical planning and postoperative advancement of activity in patients undergoing operative fixation of middle-third clavicle fractures. Basic Science Study; Biomechanics. Published by Elsevier Inc.

  2. Avascular Necrosis of Acetabulum: The Hidden Culprit of Resistant Deep Wound Infection and Failed Fixation of Fracture Acetabulum - A Case Report.

    PubMed

    K, Kandhari V; M, Desai M; S, Bava S; N, Wade R

    2015-01-01

    Chances of avascular necrosis of acetabulum are rare as it enjoys a rich blood supply. But cases of post - traumatic avascular necrosis of acetabulum following fracture of posterior column have been well documented. Importance of identifying and suspecting the avascular necrosis of acetabulum is essential in cases of failed fixation of fracture acetabulum, previously operated using extensile approach to acetabulum; either extended anterior ilio - femoral or tri - radiate approach. Such patients usually present with repeated deep bone infection or with early failure of fixation with aseptic loosening and migration of its components. We present a similar case. 40 years female presented with inadequately managed transverse fracture of left acetabulum done by anterior extended ilio-inguinal approach. The fixation failed. She presented 6 months later with painful hip. Cemented total hip replacement was performed with reconstruction of acetabulum by posterior column plating. Six months postoperatively patient presented with dislodgement of cup, pelvic discontinuity and sinus in the thigh. Two stage revision surgery was planned. First implant, removal; debridement and antibiotic spacer surgery was performed. At second stage of revision total hip replacement, patient had Paprosky grade IIIb defect in acetabulum. Spacer was removed through the posterior approach. Anterior approach was taken for anterior plating. Intra-operatively external iliac pulsations were found to be absent so procedure was abandoned after expert opinion. Postoperatively digital subtraction angiography demonstrated a chronic block in the external iliac artery and corona mortis was the only patent vascular channel providing vascular to the left lower limb. Thus, peripheral limb was stealing blood supply from the acetabulum to maintain perfusion. Patient was ultimately left with pelvic discontinuity, excision arthroplasty and pseudoarthrosis of the left hip. Avascular necrosis of acetabulum is a rare entity & often not recognized. One should be suspicious about diagnosis of avascular necrosis of acetabulum in select cases of failed acetabular fixation, previously operated via extensile anterior ilio - inguinal approach. Angiographic evaluation is essential in revision cases of failed acetabular fixation. Corona mortis (crown or circle of death) can sometimes act as a savior of limb.

  3. Allograft-Prosthetic Composite Reconstruction for Massive Proximal Humeral Bone Loss in Reverse Shoulder Arthroplasty.

    PubMed

    Sanchez-Sotelo, Joaquin; Wagner, Eric R; Sim, Franklin H; Houdek, Matthew T

    2017-12-20

    Reverse total shoulder arthroplasty (RTSA) performed in the setting of massive proximal humeral bone loss often requires special reconstructive techniques. Restoration of the proximal part of the humerus with an allograft provides a number of theoretical benefits, including implant support, restoration of humeral length, deltoid tensioning, and an opportunity to repair the posterior aspect of the cuff to improve strength in external rotation and repair of the subscapularis to improve stability. However, reverse allograft-prosthesis composites (APCs) are costly, are technically demanding to use, and can be compromised by progressive allograft resorption. Between 2005 and 2012, the lead author used an APC reconstruction in 8 primary and 18 revision RTSAs (26 patients; mean age, 62 years; mean body mass index, 27.9 kg/m). The indications for the primary RTSAs included severe proximal humeral bone loss after trauma (n = 5) and tumor resection (n = 3). The indications in the revision setting were failed hemiarthroplasty (n = 11), anatomic total shoulder arthroplasty (n = 4), and reverse arthroplasty (n = 3). The most common reason for revision was instability (n = 10). A compression plate was used for graft-to-host fixation in all shoulders. Shoulders were assessed for pain, motion, American Shoulder and Elbow Surgeons (ASES) score, Simple Shoulder Test (SST) score, Neer score, revision or reoperation, radiographic evidence of graft union or resorption, and implant fixation. The mean duration of follow-up was 4 years (range, 2 to 10 years). RTSA using an APC construct resulted in substantial improvements in pain scores (p < 0.0001), elevation (p < 0.0001), and external rotation (p = 0.004). With the numbers available, there were no significant differences in clinical outcomes between primary and revision cases. No patients required revision surgery for nonunion at the host-allograft junction. The mean time to union was 7 months, with 1 patient requiring bone-grafting for delayed union. Other complications included dislocation, deep infection, graft fracture, and periprosthetic fracture distal to the previous APC construct in 1 patient each. The 2 and 5-year revision-free survival rate was 96%. Reconstruction of proximal humeral bone loss with an APC at the time of primary or revision RTSA is safe and effective, with acceptable functional outcomes and complication rates. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  4. Tibiotalar joint arthrodesis for the treatment of severe ankle joint degeneration secondary to rheumatoid arthritis.

    PubMed

    Caron, M; Kron, E; Saltrick, K R

    1999-04-01

    The technical aspects of fusion of the rheumatoid ankle do not deviate from those in the post-traumatic or osteoarthritic ankle. Screw fixation can usually be achieved, and rarely is fixation failure a problem in rheumatoid ankle arthrodesis. If fixation is difficult because of deformity or bone quality, external fixation or locking intramedullary nails should be used. The placement of cannulated screws and adequacy of screw fixation has not been a problem (Fig. 13). Screw fixation provides compression and prevents rotation. The surgeon, however, needs to be assured that no screws invade the subtalar joint and that all threads are beyond the arthrodesis site. A washer may be necessary for further stability if this screw is not inserted at too great an angle. The authors have found that troughing out of the cortical surface of the tibia with a power bur aids in screw insertion. Not only does the trough act as a countersink, but it also provides a path for screw insertion and prevents palpable screw irritation. Malalignment is unforgiving. The foot must be placed neutral to dorsiflexion and plantarflexion. Equinus positioning places added stress on the tibia and a back-knee gait occurs. Approximately 5 degrees of valgus is recommended, and varus positioning is unforgiving. Internal and external rotation is determined by the position of the contralateral extremity. Nonunion does not seem to be a problem with rigid internal fixation to any greater degree in patients with RA. Despite this, patients may continue to have pain despite solid fusion, which can be caused by incomplete correction of deformity, painful internal fixation, or adjacent joint pathology. Additionally, patients may experience supramalleolar pain above the fusion site consistent with tibial stress fracture, which is more common if the subtalar or midtarsal joint is rigid or if the patient is obese. A rocker sole shoe with impact-absorbing soles used after brief periods of guarded mobilization in a removable walking cast alleviates this stress on the tibia. Neurovascular insult can be avoided with careful dissection direct to bone, incisions placed in nerve-free zones, and avoidance of plunging deep posteriorly-medially and anteriorly when dissecting and resecting surfaces. Arthrodesis of the tibiotalar joint in the patient with RA should be performed to relieve severe pain caused by advanced arthrosis. Achieving a solid arthrodesis does not seem to be a problem and provides the patient with pain relief; however, marked improvement in patient function and level of activity remains limited by the nature of RA and adjacent joint involvement.

  5. Comparative fixation methods of cervical disc arthroplasty versus conventional methods of anterior cervical arthrodesis: serration, teeth, keels, or screws?

    PubMed

    Cunningham, Bryan W; Hu, Nianbin; Zorn, Candace M; McAfee, Paul C

    2010-02-01

    Using a synthetic vertebral model, the authors quantified the comparative fixation strengths and failure mechanisms of 6 cervical disc arthroplasty devices versus 2 conventional methods of cervical arthrodesis, highlighting biomechanical advantages of prosthetic endplate fixation properties. Eight cervical implant configurations were evaluated in the current investigation: 1) PCM Low Profile; 2) PCM V-Teeth; 3) PCM Modular Flange; 4) PCM Fixed Flange; 5) Prestige LP; 6) Kineflex/C disc; 7) anterior cervical plate + interbody cage; and 8) tricortical iliac crest. All PCM treatments contained a serrated implant surface (0.4 mm). The PCM V-Teeth and Prestige contained 2 additional rows of teeth, which were 1 mm and 2 mm high, respectively. The PCM Modular and Fixed Flanged devices and anterior cervical plate were augmented with 4 vertebral screws. Eight pullout tests were performed for each of the 8 conditions by using a synthetic fixation model consisting of solid rigid polyurethane foam blocks. Biomechanical testing was conducted using an 858 Bionix test system configured with an unconstrained testing platform. Implants were positioned between testing blocks, using a compressive preload of -267 N. Tensile load-to-failure testing was performed at 2.5 mm/second, with quantification of peak load at failure (in Newtons), implant surface area (in square millimeters), and failure mechanisms. The mean loads at failure for the 8 implants were as follows: 257.4 +/- 28.54 for the PCM Low Profile; 308.8 +/- 15.31 for PCM V-Teeth; 496.36 +/- 40.01 for PCM Modular Flange; 528.03+/- 127.8 for PCM Fixed Flange; 306.4 +/- 31.3 for Prestige LP; 286.9 +/- 18.4 for Kineflex/C disc; 635.53 +/- 112.62 for anterior cervical plate + interbody cage; and 161.61 +/- 16.58 for tricortical iliac crest. The anterior plate exhibited the highest load at failure compared with all other treatments (p < 0.05). The PCM Modular and Fixed Flange PCM constructs in which screw fixation was used exhibited higher pullout loads than all other treatments except the anterior plate (p < 0.05). The PCM VTeeth and Prestige and Kineflex/C implants exhibited higher pullout loads than the PCM Low Profile and tricortical iliac crest (p < 0.05). Tricortical iliac crest exhibited the lowest pullout strength, which was different from all other treatments (p < 0.05). The surface area of endplate contact, measuring 300 mm(2) (PCM treatments), 275 mm(2) (Prestige LP), 250 mm(2) (Kineflex/C disc), 180 mm(2) (plate + cage), and 235 mm(2) (tricortical iliac crest), did not correlate with pullout strength (p > 0.05). The PCM, Prestige, and Kineflex constructs, which did not use screw fixation, all failed by direct pullout. Screw fixation devices, including anterior plates, led to test block fracture, and tricortical iliac crest failed by direct pullout. These results demonstrate a continuum of fixation strength based on prosthetic endplate design. Disc arthroplasty constructs implanted using vertebral body screw fixation exhibited the highest pullout strength. Prosthetic endplates containing toothed ridges (>or= 1 mm) or keels placed second in fixation strength, whereas endplates containing serrated edges exhibited the lowest fixation strength. All treatments exhibited greater fixation strength than conventional tricortical iliac crest. The current study offers insights into the benefits of various prosthetic endplate designs, which may potentially improve acute fixation following cervical disc arthroplasty.

  6. Computational Evaluation of the Effects of Bone Ingrowth on Bone Resorptive Remodeling after a Cementless Total Hip Arthroplasty

    NASA Astrophysics Data System (ADS)

    Jung, Duk-Young; Kang, Yu-Bong; Tsutsumi, Sadami; Nakai, Ryusuke; Ikeuchi, Ken; Sekel, Ron

    In this study, we simulated a wide cortex separation from a cementless hip prosthesis using the bone resorption remodeling method that is based on the generation of high compressive stress around the distal cortical bone. Thereafter, we estimated the effect on late migration quantities of the hip prosthesis produced by the interface state arising from bone ingrowth. This was accomplished using cortical bone remodeling over a long period of time. Two-dimensional natural hip and implanted hip FEM models were constructed with each of the following interface statements between the bone and prosthesis: (1) non-fixation, (2) proximal 1/3, (3) proximal 2/3 and (4) full-fixation. The fixation interfaces in the fully and partially porous coated regions were rigidly fixed by bony ingrowth. The non-fixation model was constructed as a critical situation, with the fibrous or bony tissue not integrated at all into the implant surface. The daily load history was generated using the three loading cases of a one-legged stance as well as abduction and adduction motions. With the natural hip and one-legged stance, the peak compressive principal stresses were found to be under the criteria value for causing bone resorption, while no implant movement occurred. The migration magnitude of the stem of the proximal 1/3 fixation model with adduction motion was much higher, reaching 6%, 11%and 21%greater than those of the non-fixation, proximal 2/3 fixation and all-fixation models, respectively. The full-fixation model showed the lowest compressive principal stress and implant movement. Thus, we concluded that the late loosening and subsequent movement of the stem in the long term could be estimated with the cortical bone remodeling method based on a high compressive stress at the bone-implant interface. The change caused at the bone-prosthesis interface by bony or fibrous tissue ingrowth constituted the major factor in determining the extent of cortical bone resorption occurring with clinical loosening and subsequent implant movement.

  7. Biomechanical comparison of blade plate and intramedullary nail fixation for tibiocalcaneal arthrodesis.

    PubMed

    Lee, Arthur T; Sundberg, Eric B; Lindsey, Derek P; Harris, Alex H S; Chou, Loretta B

    2010-02-01

    Tibiocalcaneal arthrodesis is an uncommon salvage procedure used for complex problems of the ankle and hindfoot. A biomechanical evaluation of the fixation constructs of this procedure has not been studied previously. The purpose of this study was to compare intramedullary nail to blade plate fixation in a deformity model in fatigue endurance testing and load to failure. Nine matched pairs of fresh frozen cadaveric legs underwent talectomy followed by fixation with a blade plate and 6.5-mm fully threaded cancellous screw or an ankle arthrodesis intramedullary nail. The specimens were loaded to 270 N at a rate of 3 Hz for a total of 250,000 cycles, followed by loading to failure. Intramedullary nail fixation demonstrated greater mean stiffness throughout the fatigue endurance testing, from cycles 10 through 250,000 (blade plate versus intramedullary nail; cycle 10, 93 +/- 34 N/mm versus 117 +/- 40 N/mm (t = 2.33, p = 0.04); cycle 100, 89 +/- 34 N/mm versus 118 +/- 42 N/mm (t = 3.16, p = 0.01); cycle 1000, 86 +/- 32 N/mm versus 120 +/- 45 N/mm (t = 3.52, p = 0.01); cycle 10,000, 83 +/- 36 N/mm versus 128 +/- 50 N/mm (t = 3.80, p = 0.01); cycle 100,000, 82 +/- 34 N/mm versus 126 +/- 52 N/mm (t = 3.70, p = 0.01); cycle 250,000, 80 +/- 31 N/mm versus 125 +/- 49 N/mm (t = 4.2, p = 0.003). There was no statistically significant difference between the intramedullary nail and blade plate fixation in cycle one or in load to failure; cycle 10, blade plate 70 +/- 38 N/mm and intramedullary nail 67 +/- 20 N/mm (t = 0.60, p = 0.56); load to failure, blade plate 808 +/- 193 N, IMN 1074 +/- 290 N) (p = 0.15). Intramedullary nail fixation was biomechanically superior to blade plate and screw fixation in a tibiocalcaneal arthrodesis construct. The ankle arthrodesis intramedullary nail provides greater stiffness for fixation in tibiocalcaneal arthrodesis, which may improve healing.

  8. Interrami intraoral fixation technique for severe mandibular rifle fragmented bullet injury management.

    PubMed

    Shuker, Sabri T

    2013-07-01

    Interrami intraoral Kirschner wire fixation technique is presented for the reduction, stabilization, and immobilization of a pulverized and avulsed lower jaw caused by rifle fragmented bullet injuries. This indirect mandibular war injury fixation technique was tolerated by the patients and tissue more than any indirect external fixation. In addition, it is easier than open reduction using large bone plates for disrupted ballistics mandibular injury defects. An interrami intraoral fixation is appropriate for severely disrupted mandibular hard and soft tissues, and has been adapted in cases of mass casualties and limited resources. Benefits of use include limited hospital beds and fewer follow-up visits. Rifle fragmented bullet injuries need more attention for several reasons: not only because of the higher mortality and devastating nature of the injuries, but also because these injuries are responsible for an unreported type of bullet biomechanism wounding in the craniofacial region. In turn, this necessitates specialized victim management. The survival rates depend on immediate proper execution of airway, breathing, and circulation, which become more complicated as it relates to airway compromise and oropharyngeal hemorrhage resuscitation. Survival is predicated on the implementation of feasible, sensible, life-saving techniques that are applied at the appropriate time.

  9. Fixation, transient landscape, and diffusion dilemma in stochastic evolutionary game dynamics

    NASA Astrophysics Data System (ADS)

    Zhou, Da; Qian, Hong

    2011-09-01

    Agent-based stochastic models for finite populations have recently received much attention in the game theory of evolutionary dynamics. Both the ultimate fixation and the pre-fixation transient behavior are important to a full understanding of the dynamics. In this paper, we study the transient dynamics of the well-mixed Moran process through constructing a landscape function. It is shown that the landscape playing a central theoretical “device” that integrates several lines of inquiries: the stable behavior of the replicator dynamics, the long-time fixation, and continuous diffusion approximation associated with asymptotically large population. Several issues relating to the transient dynamics are discussed: (i) multiple time scales phenomenon associated with intra- and inter-attractoral dynamics; (ii) discontinuous transition in stochastically stationary process akin to Maxwell construction in equilibrium statistical physics; and (iii) the dilemma diffusion approximation facing as a continuous approximation of the discrete evolutionary dynamics. It is found that rare events with exponentially small probabilities, corresponding to the uphill movements and barrier crossing in the landscape with multiple wells that are made possible by strong nonlinear dynamics, plays an important role in understanding the origin of the complexity in evolutionary, nonlinear biological systems.

  10. Treatment of cervical spine fractures with halo vest method in children and young people.

    PubMed

    Tomaszewski, Ryszard; Pyzińska, Marta

    2014-01-01

    The Halo Vest method is a non-invasive treatment of cervical spine fractures. It is successfully applied in adults, which is supported by numerous studies, but has rarely been used among children and young people. There is little published research in this field. The aim of the paper is to present the effectiveness of Halo Vest external fixation in children and to evaluate the complication rate of this method. A retrospective study of 6 patients with cervical spine fractures with an average age of 13.3 years (range: 10 to 17 years) treated with Halo Vest external fixation between 2004 and 2013. The type and cause of fracture, treatment outcome and complications were evaluated. The average duration of follow-up was 55 months. In 5 cases, the treatment result was satisfactory. In one case, there were complications in the form of an external infection around the cranial pins. 1. The Halo Vest system can be applied as a non-operative method of treating cervical spine fractures in children and young people. 2. The criteria of eligibility for specific types of cervical spine fracture treatment in children and young people require further investigation, especially with regard to eliminating complications.

  11. Comparison of calcaneal fixation of a retrograde intramedullary nail with a fixed-angle spiral blade versus a fixed-angle screw.

    PubMed

    Klos, Kajetan; Gueorguiev, Boyko; Schwieger, Karsten; Fröber, Rosemarie; Brodt, Steffen; Hofmann, Gunther O; Windolf, Markus; Mückley, Thomas

    2009-12-01

    Retrograde intramedullary nailing is an established technique for tibiotalocalcaneal arthrodesis (TTCA). In poor bone stock (osteoporosis, neuroarthropathy), device fixation in the hindfoot remains a problem. Fixed-angle spiral-blade fixation of the nail in the calcaneus could be useful. In seven matched pairs of human below-knee specimens, bone mineral density (BMD) was determined, and TTCA was performed with an intramedullary nail (Synthes Hindfoot Arthrodesis Nail HAN Expert Nailing System), using a conventional screw plus a fixed-angle spiral blade versus a conventional screw plus a fixed-angle screw, in the calcaneus. The constructs were subjected to quasi-static loading (dorsiflexion/plantarflexion, varus/valgus, rotation) and to cyclic loading to failure. Parameters studied were construct neutral zone (NZ) and range of motion (ROM), and number of cycles to failure. With dorsiflexion/plantarflexion loading, the screw-plus-spiral-blade constructs had a significantly smaller ROM in the quasi-static test (p = 0.028) and early in the cyclic test (p = 0.02); differences in the other parameters were not significant. There was a significant correlation between BMD and cycles to failure for the two-screw constructs (r = 0.94; p = 0.002) and for the screw-plus-spiral-blade constructs (r = 0.86; p = 0.014). In TTCA with a HAN Expert Nailing System, the use of a calcaneal spiral blade can further reduce motion within the construct. This may be especially useful in poor bone stock. Results obtained in this study could be used to guide the operating surgeon's TTCA strategy.

  12. First metatarsal-phalangeal joint arthrodesis: a biomechanical assessment of stability.

    PubMed

    Politi, Joel; John, Hayes; Njus, Glen; Bennett, Gordon L; Kay, David B

    2003-04-01

    First metatarsal phalangeal joint (MTP) arthrodesis is a commonly performed procedure for the treatment of hallux rigidus, severe and recurrent bunion deformities, rheumatoid arthritis and other less common disorders of the joint. There are different techniques of fixation of the joint to promote arthrodesis including oblique lag screw fixation, lag screw and dorsal plate fixation, crossed Kirschner wires, dorsal plate fixation alone and various types of external fixation. Ideally the fixation method should be reproducible, lead to a high rate of fusion, and have a low incidence of complications. In the present study, we compared the strength of fixation of five commonly utilized techniques of first MTP joint arthrodesis. These were: 1. Surface excision with machined conical reaming and fixation with a 3.5 mm cortical interfragmentary lag screw. 2. Surface excision with machined conical reaming and fixation with crossed 0.062 Kirschner wires. 3. Surface excision with machined conical reaming and fixation with a 3.5 mm cortical lag screw and a four hole dorsal miniplate secured with 3.5 mm cortical screws. 4. Surface excision with machined conical reaming and fixation with a four hole dorsal miniplate secured with 3.5 mm cortical screws and no lag screw. 5. Planar surface excision and fixation with a single oblique 3.5 mm interfragmentary cortical lag screw. Testing was done on an Instron materials testing device loading the first MTP joint in dorsiflexion. Liquid metal strain gauges were placed over the joint and micromotion was detected with varying loads and cycles. The most stable technique was the combination of machined conical reaming and an oblique interfragmentary lag screw and dorsal plate. This was greater than two times stronger than an oblique lag screw alone. Dorsal plate alone and Kirschner wire fixation were the weakest techniques. First MTP fusion is a commonly performed procedure for the treatment of a variety of disorders of the first MTP joint. The most stable technique for obtaining fusion in this study was the combination of an oblique lag screw and a dorsal plate. This should lead to higher rates of arthrodesis.

  13. Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study.

    PubMed

    Lewis, Gregory S; Caroom, Cyrus T; Wee, Hwabok; Jurgensmeier, Darin; Rothermel, Shane D; Bramer, Michelle A; Reid, John Spence

    2015-10-01

    The biomechanical difficulty in fixation of a Vancouver B1 periprosthetic fracture is purchase of the proximal femoral segment in the presence of the hip stem. Several newer technologies provide the ability to place bicortical locking screws tangential to the hip stem with much longer lengths of screw purchase compared with unicortical screws. This biomechanical study compares the stability of 2 of these newer constructs to previous methods. Thirty composite synthetic femurs were prepared with cemented hip stems. The distal femur segment was osteotomized, and plates were fixed proximally with either (1) cerclage cables, (2) locked unicortical screws, (3) a composite of locked screws and cables, or tangentially directed bicortical locking screws using either (4) a stainless steel locking compression plate system with a Locking Attachment Plate (Synthes) or (5) a titanium alloy Non-Contact Bridging system (Zimmer). Specimens were tested to failure in either axial or torsional quasistatic loading modes (n = 3) after 20 moderate load preconditioning cycles. Stiffness, maximum force, and failure mechanism were determined. Bicortical constructs resisted higher (by an average of at least 27%) maximum forces than the other 3 constructs in torsional loading (P < 0.05). Cables constructs exhibited lower maximum force than all other constructs, in both axial and torsional loading. The bicortical titanium construct was stiffer than the bicortical stainless steel construct in axial loading. Proximal fixation stability is likely improved with the use of bicortical locking screws as compared with traditional unicortical screws and cable techniques. In this study with a limited sample size, we found the addition of cerclage cables to unicortical screws may not offer much improvement in biomechanical stability of unstable B1 fractures.

  14. Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study

    PubMed Central

    Lewis, Gregory S.; Caroom, Cyrus T.; Wee, Hwabok; Jurgensmeier, Darin; Rothermel, Shane D.; Bramer, Michelle A.; Reid, J. Spence

    2015-01-01

    Objectives The biomechanical difficulty in fixation of a Vancouver B1 periprosthetic fracture is purchase of the proximal femoral segment in the presence of the hip stem. Several newer technologies provide the ability to place bicortical locking screws tangential to the hip stem with much longer lengths of screw purchase compared to unicortical screws. This biomechanical study compares the stability of two of these newer constructs to previous methods. Methods Thirty composite synthetic femurs were prepared with cemented hip stems. The distal femur segment was osteotomized, and plates were fixed proximally with either: (1) cerclage cables; (2) locked unicortical screws; (3) a composite of locked screws and cables; or tangentially directed bicortical locking screws using either (4) a stainless steel LCP system with a Locking Attachment Plate (Synthes), or (5) a titanium alloy NCB system (Zimmer). Specimens were tested to failure in either axial or torsional quasi-static loading modes (n = 3) after 20 moderate load pre-conditioning cycles. Stiffness, maximum force, and failure mechanism were determined. Results Bicortical constructs resisted higher (by an average of at least 27%) maximum forces than the other three constructs in torsional loading (p<0.05). Cables constructs exhibited lower maximum force than all other constructs, in both axial and torsional loading. The bicortical titanium construct was stiffer than the bicortical stainless steel construct in axial loading. Conclusions Proximal fixation stability is likely improved with the use of bicortical locking screws as compared to traditional unicortical screws and cable techniques. In this study with a limited sample size, we found the addition of cerclage cables to unicortical screws may not offer much improvement in biomechanical stability of unstable B1 fractures. PMID:26053467

  15. [Treatment of sternoclavicular joint dislocation with sternoclavicular hook plate fixation].

    PubMed

    Liu, Pan; Yuan, Jia-bin; Liu, Zhong-qian; Lu, Bing; Wang, Yue

    2015-08-01

    To evaluate the technique and therapeutic effect of sternoclavicular hook plate fixation in treating sternoclavicular joint (SCJ) dislocation. From January 2010 to March 2014,6 patients with SCJ dislocation were treated with sternoclavicular hook plate fixation in our hospital. Among the 6 patients, 5 patients were male and 1 patient was female, and the average age was 34 years, ranging from 26 to 48 years. The course of the disease ranged from 3 to 20 days. All the SCJ dislocations were caused by external injury and accompanied with the symptoms of swelling pain and obvious shoulder joint activity restricted in affected side. All SCJ dislocations were anterior dislocation by the diagnosis of X-ray and CT scan. The postoperative curative effect was evaluated according to Rockwood score. All the patients' operative incision were healed well and in good appearance. X-ray showed that the dislocated SCJ was well reduced and the plate was on right position. All the 6 patients were followed up for 4 to 18 months, with an average of 12 months. The results were evaluated according to Rockwood score, 4 got excellent results, 1 good and 1 fair. No fixation loosening, redislocation or side injury such as vessel, nerve or pleura injury were found. With sternoclavicular hook plate fixation, SCJ dislocation could be reduced while keeping its amphiarthrodial function and the completeness of the cartilage surface. Sternoclavicular hook plate fixation has advantages of safety and stabilization in fixation, and patients can begin function exercises earlier.

  16. Anterior subcutaneous internal fixation for treatment of unstable pelvic fractures

    PubMed Central

    2014-01-01

    Background Fractures of the pelvic ring including disruption of the posterior elements in high-energy trauma have both high morbidity and mortality rates. For some injury pattern part of the initial resuscitation includes either external fixation or plate fixation to close the pelvic ring and decrease blood loss. In certain situations – especially when associated with abdominal trauma and the need to perform laparotomies – both techniques may put the patient at risk of either pintract or deep plate infections. We describe an operative approach to percutaneously close and stabilize the pelvic ring using spinal implants as an internal fixator and report the results in a small series of patients treated with this technique during the resuscitation phase. Findings Four patients were treated by subcutaneous placement of an internal fixator. Screw fixation was carried out by minimally invasive placement of two supra-acetabular iliac screws. Afterwards, a subcutaneous transfixation rod was inserted and attached to the screws after reduction of the pelvic ring. All patients were allowed to fully weight-bear. No losses of reduction or deep infections occurred. Fracture healing was uneventful in all cases. Conclusion Minimally invasive fixation is an alternative technique to stabilize the pelvic ring. The clinical results illustrate that this technique is able to achieve good results in terms of maintenance of reduction the pelvic ring. Also, abdominal surgeries no longer put the patient at risk of infected pins or plates. PMID:24606833

  17. Comparative study of safety and efficacy of synthetic surgical glue for mesh fixation in ventral rectopexy.

    PubMed

    Silveira, Raquel Kelner; Domingie, Sophie; Kirzin, Sylvain; de Melo Filho, Djalma Agripino; Portier, Guillaume

    2017-10-01

    Ventral mesh rectopexy (VMR) is a surgical option to treat rectal prolapse with pelvic floor dysfunction (PFD). Using synthetic surgical glue to fix the mesh to the anterior rectal wall after ventral dissection could be advantageous in comparison with sutured or stapled fixation. This study aimed to evaluate the safety and efficacy of synthetic surgical glue for mesh fixation compared with suture mesh fixation in VMR. This observational cohort study is a retrospective analysis conducted in a University Hospital Pelvic Surgery Center. All consecutive female patients (n = 176) who underwent laparoscopic or laparotomic VMR between January 2009 and December 2014 were included. Two groups were defined based on mesh fixation technique of the rectal wall: VMR with synthetic glue (n = 66) and VMR with suture (n = 110). The recurrence-free survival after VMR was determined by Kaplan-Meier method and multivariate analysis by Cox regression. Short-term postoperative complications, postoperative symptom improvement, the need for complementary treatment postoperatively, and procedure length were evaluated. A total of 176 females patients (mean age, 58.6 ± 13.7 years) underwent VMR with synthetic mesh. Mean recurrence-free survivals after VMR were 17.16 (CI 95% 16.54-17.80) and 17.33 (CI 95% 16.89-17.77) months in the glue group and the suture group, respectively (p > 0.05). Cox regression identified an independent effect on the recurrence risk of the external rectal prolapse, alone, or in combination with other anatomical abnormalities (HR = 0.37; CI 95% 0.14-0.93; p = 0.03). There was no significant difference of short-term postoperative morbidity, procedure length, postoperative symptom improvement, or need for complementary treatment postoperatively between suture versus glue groups (all p > 0.05). Use of glue to fix the mesh in VMR was safe and had no impact on outcomes. External prolapse was the unique significant predictive factor for recurrence.

  18. External fixation of proximal tracheal airway stents: a modified technique.

    PubMed

    Majid, Adnan; Fernandez-Bussy, Sebastian; Kent, Michael; Folch, Erik; Fernandez, Liliana; Cheng, George; Gangadharan, Sidhu P

    2012-06-01

    Treatment of subglottic and proximal tracheal stenosis for nonsurgical candidates includes tracheostomy, Montgomery T tubes, and silicone stents. When used in lesions with concomitant malacia, silicone stents have a high incidence of migration. We describe a simple and effective technique of securing endoluminal stents using an Endo Close suturing device (Coviden, Boston, MA) and an external silicone button in 9 consecutive patients. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Biomechanical comparison of 3.0 mm headless compression screw and 3.5 mm cortical bone screw in a canine humeral condylar fracture model.

    PubMed

    Gonsalves, Mishka N; Jankovits, Daniel A; Huber, Michael L; Strom, Adam M; Garcia, Tanya C; Stover, Susan M

    2016-09-20

    To compare the biomechanical properties of simulated humeral condylar fractures reduced with one of two screw fixation methods: 3.0 mm headless compression screw (HCS) or 3.5 mm cortical bone screw (CBS) placed in lag fashion. Bilateral humeri were collected from nine canine cadavers. Standardized osteotomies were stabilized with 3.0 mm HCS in one limb and 3.5 mm CBS in the contralateral limb. Condylar fragments were loaded to walk, trot, and failure loads while measuring construct properties and condylar fragment motion. The 3.5 mm CBS-stabilized constructs were 36% stiffer than 3.0 mm HCS-stabilized constructs, but differences were not apparent in quality of fracture reduction nor in yield loads, which exceeded expected physiological loads during rehabilitation. Small residual fragment displacements were not different between CBS and HCS screws. Small fragment rotation was not significantly different between screws, but was weakly correlated with moment arm length (R² = 0.25). A CBS screw placed in lag fashion provides stiffer fixation than an HCS screw, although both screws provide similar anatomical reduction and yield strength to condylar fracture fixation in adult canine humeri.

  20. The Extended Direct Anterior Approach for Column Augmentation in the Deficient Pelvis: A Novel Surgical Technique, and Case Series Report.

    PubMed

    Spanyer, Jonathon M; Beaumont, Christopher M; Yerasimides, Jonathan G

    2017-02-01

    Anterior column deficiency of the pelvis may pose a serious threat to the stability of the acetabular component after total hip arthroplasty and, thus, jeopardize the overall success of the procedure. After Institutional Review Board approval, a retrospective review was undertaken to identify all patients undergoing revision total hip arthroplasty with anterior column augmentation through an extended direct anterior approach. Demographics and surgical details were collected, and subjects were followed for a 2-year minimum period to measure patient outcomes and to evaluate for the stability of construct fixation. A novel surgical procedure description was provided and supplemented with an illustrative case example. At 2 years post augmentation, patients had favorable functional outcomes with radiologic evidence of stable fixation. Proximal extension of the direct anterior approach to the hip can facilitate anterior column access and augmentation to improve stability of the hip reconstruction. This treatment may be an alternative to spanning constructs such as cup-cage constructs and custom implants, affording the potential for long-term biologic fixation. Further investigation into this technique is warranted. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. An efficient copper-based magnetic nanocatalyst for the fixation of carbon dioxide at atmospheric pressure.

    PubMed

    Sharma, Rakesh Kumar; Gaur, Rashmi; Yadav, Manavi; Goswami, Anandarup; Zbořil, Radek; Gawande, Manoj B

    2018-01-30

    In the last few decades, the emission of carbon dioxide (CO 2 ) in the environment has caused havoc across the globe. One of the most promising strategies for fixation of CO 2 is the cycloaddition reaction between epoxides and CO 2 to produce cyclic carbonates. For the first time, we have fabricated copper-based magnetic nanocatalyst and have applied for the CO 2 fixation. The prepared catalyst was thoroughly characterized using various techniques including XRD, FT-IR, TEM, FE-SEM, XPS, VSM, ICP-OES and elemental mapping. The reactions proceeded at atmospheric pressure, relatively lower temperature, short reaction time, solvent- less and organic halide free reaction conditions. Additionally, the ease of recovery through an external magnet, reusability of the catalyst and excellent yields of the obtained cyclic carbonates make the present protocol practical and sustainable.

  2. Biomechanical evaluation of fixation of intra-articular fractures of the distal part of the radius in cadavera: Kirschner wires compared with calcium-phosphate bone cement.

    PubMed

    Yetkinler, D N; Ladd, A L; Poser, R D; Constantz, B R; Carter, D

    1999-03-01

    The purpose of this study was to compare the biomechanical efficacy of an injectable calcium-phosphate bone cement (Skeletal Repair System [SRS]) with that of Kirschner wires for the fixation of intraarticular fractures of the distal part of the radius. Colles fractures (AO pattern, C2.1) were produced in ten pairs of fresh-frozen human cadaveric radii. One radius from each pair was randomly chosen for stabilization with SRS bone cement. These ten radii were treated with open incision, impaction of loose cancellous bone with use of a Freer elevator, and placement of the SRS bone cement by injection. In the ten control specimens, the fracture was stabilized with use of two horizontal and two oblique Kirschner wires. The specimens were cyclically loaded to a peak load of 200 newtons for 2000 cycles to evaluate the amount of settling, or radial shortening, under conditions simulating postoperative loading with the limb in a cast. Each specimen then was loaded to failure to determine its ultimate strength. The amount of radial shortening was highly variable among the specimens, but it was consistently higher in the Kirschner-wire constructs than in the bone fixed with SRS bone cement within each pair of radii. The range of shortening for all twenty specimens was 0.18 to 4.51 millimeters. The average amount of shortening in the SRS constructs was 50 percent of that in the Kirschner-wire constructs (0.51+/-0.34 compared with 1.01+/-1.23 millimeters; p = 0.015). With the numbers available, no significant difference in ultimate strength was detected between the two fixation groups. This study showed that fixation of an intra-articular fracture of the distal part of a cadaveric radius with biocompatible calcium-phosphate bone cement produced results that were biomechanically comparable with those produced by fixation with Kirschner wires. However, the constructs that were fixed with calcium-phosphate bone cement demonstrated less shortening under simulated cyclic load-bearing.

  3. Tibial lengthening over intramedullary nails

    PubMed Central

    Burghardt, R. D.; Manzotti, A.; Bhave, A.; Paley, D.

    2016-01-01

    Objectives The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method. Methods In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group. Results The mean external fixation time for the LON group was 2.6 months and for the matched case group was 7.6 months. The mean lengthening amounts for the LON and the matched case groups were 5.2 cm and 4.9 cm, respectively. The radiographic consolidation time in the LON group was 6.6 months and in the matched case group 7.6 months. Using a clinical and radiographic outcome score that was designed for this study, the outcome was determined to be excellent in 17 and good in two patients for the LON group. The outcome was excellent in 14 and good in five patients in the matched case group. The LON group had increased blood loss and increased cost. The LON group had four deep infections; the matched case group did not have any deep infections. Conclusions The outcomes in the LON group were comparable with the outcomes in the matched case group. The LON group had a shorter external fixation time but experienced increased blood loss, increased cost, and four cases of deep infection. The advantage of reducing external fixation treatment time may outweigh these disadvantages in patients who have a healthy soft-tissue envelope. Cite this article: J. E. Herzenberg. Tibial lengthening over intramedullary nails: A matched case comparison with Ilizarov tibial lengthening. Bone Joint Res 2016;5:1–10. doi: 10.1302/2046-3758.51.2000577 PMID:26764351

  4. Effects of Carbon Dioxide and Oxygen on the Regulation of Photosynthetic Carbon Metabolism by Ammonia in Spinach Mesophyll Cells 1

    PubMed Central

    Lawyer, Arthur L.; Cornwell, Karen L.; Larsen, Peder O.; Bassham, James A.

    1981-01-01

    Photosynthetic carbon metabolism of isolated spinach mesophyll cells was characterized under conditions favoring photorespiratory (PR; 0.04% CO2 and 20% O2) and nonphotorespiratory (NPR; 0.2% CO2 and 2% O2) metabolism, as well as intermediate conditions. Comparisons were made between the metabolic effects of extracellularly supplied NH4+ and intracellular NH4+, produced primarily via PR metabolism. The metabolic effects of 14CO2 fixation under PR conditions were similar to perturbations of photosynthetic metabolism brought about by externally supplied NH4+; both increased labeling and intracellular concentrations of glutamine at the expense of glutamate and increased anaplerotic synthesis through α-ketoglutarate. The metabolic effects of added NH4+ during NPR fixation were greater than those during PR fixation, presumably due to lower initial NH4+ levels during NPR fixation. During PR fixation, addition of ammonia caused decreased pools and labeling of glutamate and serine and increased glycolate, glyoxylate, and glycine labeling. The glycolate pathway was thus affected by increased rates of carbon flow and decreased glutamate availability for glyoxylate transamination, resulting in increased usage of serine for transamination. Sucrose labeling decreased with NH4+ addition only during PR fixation, suggesting that higher photosynthetic rates under NPR conditions can accommodate the increased drain of carbon toward amino acid synthesis while maintaining sucrose synthesis. PMID:16662084

  5. [Miniplate internal fixation and autogenous iliac bone graft in surgical treatment of old metatarsal fractures].

    PubMed

    Pan, Hao; Yu, Guangrong; Xiong, Wen; Zhao, Zhiming; Ding, Fan; Zheng, Qiong; Kan, Wushen

    2011-07-01

    To summarize the experience of treating old metatarsal fractures with surgery methods of miniplate internal fixation and autogenous iliac bone. Between May 2009 and July 2010, 7 patients with old metatarsal fractures were treated surgically, including 5 multi-metatarsal fractures and 2 single metatarsal fractures. There were 5 males and 2 females aged from 25 to 43 years (mean, 33 years). The time from fracture to operation was 4-12 weeks. The X-ray films showed that a small amount of callus formed at both broken ends with shortening, angulation, or rotation displacement. The surgical treatments included open reduction, internal fixation by miniplate, and autogenous iliac bone graft (1.5-2.5 cm(3)). The external plaster fixation was used in all patients for 4 to 6 weeks postoperatively (mean, 5 weeks). All incisions healed by first intention. The 7 patients were followed up 8-18 months (mean, 13.5 months). The clinical fracture healing time was 6 to 12 weeks postoperatively (mean, 8.4 weeks). No pain of planta pedis occurred while standing and walking. The American Orthopaedic Foot and Ankle Society (AOFAS) mesopedes and propodium score was 75-96 (mean, 86.4). It has the advantages of reliable internal fixation, high fracture healing rate, less complications to treat old metatarsal fractures with surgery methods of miniplate internal fixation and autogenous iliac bone graft, so it is an effective treatment method.

  6. A novel fixation system for sacroiliac dislocation fracture: internal fixation system design and biomechanics analysis.

    PubMed

    Dawei, Tian; Na, Liu; Jun, Lei; Wei, Jin; Lin, Cai

    2013-02-01

    Although there were many different types of fixation techniques for sacroiliac dislocation fracture, the treat remained challenging in posterior pelvic ring injury. The purpose of this study was to evaluate the biomechanical effects of a novel fixation system we designed. 12 human cadavers (L3-pelvic-femora) were used to compare biomechanical stability after reconstruction on the same specimens in four conditions: (1) intact, (2) cable system, (3) plate-pedicle screw system, and (4) cable system and plate-pedicle screw combination system (combination system). Biomechanical testing was performed on a material testing machine for evaluating the stiffness of the pelvic fixation construct in compression and torsion. The cable system and plate-pedicle screw system alone may be insufficient to resist vertical shearing and rotational loads; however the combination system for unstable sacroiliac dislocation fractures provided significantly greater stability than single plate-pedicle or cable fixation system. The novel fixation system for unstable sacroiliac dislocation fractures produced sufficient stability in axial compression and axial rotation test in type C pelvic ring injuries. It may also offer a better solution for sacroiliac dislocation fractures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Aphotic N2 fixation along an oligotrophic to ultraoligotrophic transect in the western tropical South Pacific Ocean

    NASA Astrophysics Data System (ADS)

    Benavides, Mar; Shoemaker, Katyanne M.; Moisander, Pia H.; Niggemann, Jutta; Dittmar, Thorsten; Duhamel, Solange; Grosso, Olivier; Pujo-Pay, Mireille; Hélias-Nunige, Sandra; Fumenia, Alain; Bonnet, Sophie

    2018-05-01

    The western tropical South Pacific (WTSP) Ocean has been recognized as a global hot spot of dinitrogen (N2) fixation. Here, as in other marine environments across the oceans, N2 fixation studies have focused on the sunlit layer. However, studies have confirmed the importance of aphotic N2 fixation activity, although until now only one had been performed in the WTSP. In order to increase our knowledge of aphotic N2 fixation in the WTSP, we measured N2 fixation rates and identified diazotrophic phylotypes in the mesopelagic layer along a transect spanning from New Caledonia to French Polynesia. Because non-cyanobacterial diazotrophs presumably need external dissolved organic matter (DOM) sources for their nutrition, we also identified DOM compounds using Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) with the aim of searching for relationships between the composition of DOM and non-cyanobacterial N2 fixation in the aphotic ocean. N2 fixation rates were low (average 0.63 ± 0.07 nmol N L-1 d-1) but consistently detected across all depths and stations, representing ˜ 6-88 % of photic N2 fixation. N2 fixation rates were not significantly correlated with DOM compounds. The analysis of nifH gene amplicons revealed a wide diversity of non-cyanobacterial diazotrophs, mostly matching clusters 1 and 3. Interestingly, a distinct phylotype from the major nifH subcluster 1G dominated at 650 dbar, coinciding with the oxygenated Subantarctic Mode Water (SAMW). This consistent pattern suggests that the distribution of aphotic diazotroph communities is to some extent controlled by water mass structure. While the data available are still too scarce to elucidate the distribution and controls of mesopelagic non-cyanobacterial diazotrophs in the WTSP, their prevalence in the mesopelagic layer and the consistent detection of active N2 fixation activity at all depths sampled during our study suggest that aphotic N2 fixation may contribute significantly to fixed nitrogen inputs in this area and/or areas downstream of water mass circulation.

  8. Axial loading screw fixation for chevron type osteotomies of the distal first metatarsal: a retrospective outcomes analysis.

    PubMed

    Murphy, Ryan M; Fallat, Lawrence M; Kish, John P

    2014-01-01

    The distal chevron osteotomy is a widely accepted technique for the treatment of hallux abductovalgus deformity. Although the osteotomy is considered to be stable, displacements of the capital fragment has been described. We propose a new method for fixation of the osteotomy involving the axial loading screw (ALS) used in addition to single screw fixation. We believe this method will provide a more mechanically stable construct. We reviewed the charts of 46 patients in whom 52 feet underwent a distal chevron osteotomy that was fixated with either 1 screw or 2 screws that included the ALS. We hypothesized that the ALS group would have fewer displacements and would heal more quickly than the single screw fixation group. We found that the group with ALS fixation had healed at a mean of 6.5 weeks and that the group with single screw fixation had healed at 9.53 weeks (p = .001). Also, 8 cases occurred of displacement of the capital fragment in the single screw, control group compared with 2 cases of displacement in the ALS group. However, this finding was not statistically significant. The addition of the ALS to single screw fixation allowed the patients to heal approximately 3 weeks earlier than single screw fixation alone. The ALS is a fixation option for the surgeon to consider when osseous correction of hallux abducto valgus is performed. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Prediction in the Processing of Repair Disfluencies: Evidence from the Visual-World Paradigm

    PubMed Central

    Lowder, Matthew W.; Ferreira, Fernanda

    2016-01-01

    Two visual-world eye-tracking experiments investigated the role of prediction in the processing of repair disfluencies (e.g., The chef reached for some salt uh I mean some ketchup…). Experiment 1 showed that listeners were more likely to fixate a critical distractor item (e.g., pepper) during the processing of repair disfluencies compared to the processing of coordination structures (e.g., …some salt and also some ketchup…). Experiment 2 replicated the findings of Experiment 1 for disfluency versus coordination constructions and also showed that the pattern of fixations to the critical distractor for disfluency constructions was similar to the fixation patterns for sentences employing contrastive focus (e.g., …not some salt but rather some ketchup…). The results suggest that similar mechanisms underlie the processing of repair disfluencies and contrastive focus, with listeners generating sets of entities that stand in semantic contrast to the reparandum in the case of disfluencies or the negated entity in the case of contrastive focus. PMID:26866657

  10. Blount Disease

    MedlinePlus

    ... involve cutting the tibia, realigning it, and holding it in place with a plate and screws (this is called an osteotomy ); some involve removing the damaged growth plate; and some use a device called an external fixator to hold ... is necessary, it will be done under general anesthesia (you will ...

  11. Fixation Options for the Volar Lunate Facet Fracture: Thinking Outside the Box.

    PubMed

    Harness, Neil G

    2016-03-01

    Background Fractures of the distal radius with small volar ulnar marginal fracture fragments are difficult to stabilize with standard volar locking plates. The purpose of this study is to describe alternative techniques available to stabilize these injuries. Materials and Methods Five patients were identified retrospectively with unstable volar lunate facet fracture fragments treated with supplemental fixation techniques. The demographic data, pre- and postoperative radiographic parameters, and early outcomes data were analyzed. The AO classification, preoperative and final postoperative ulnar variance, articular step-off, volar tilt, radial inclination, and teardrop angle were measured. The lunate subsidence and length of the volar cortex available for fixation were measured from the initial injury films. Description of Technique Lunate facet fixation was based on the morphology of the fragment, and stabilization was achieved with headless compression screws in three patients, a tension band wire construct in one, and two cortical screws in another. Results Five patients with a mean age of 58 years (range: 41-82) were included. There were two AO C3.2 and three B3.3 fractures. Preoperative radiographic measurements including radial inclination, tilt, and ulnar variance all improved after surgery and were maintained within normal limits at 3-month follow-up. There was no change in the teardrop angle at final follow-up (70-64 degrees; p = 0.14). None of the patients had loss of fixation or volar carpal subluxation. The mean visual analog scale pain score at 3 months was 1 (range: 0-2). Conclusions The morphology of volar lunate facet fracture fragments is variable, and fixation must be customized to the particular pattern. Small fragments may preclude the use of plates and screws for fixation. These fractures can be managed successfully with tension band wire constructs and headless screws. These low-profile implants may decrease the risk of tendon irritation that might accompany distally placed plates.

  12. Fixation Options for the Volar Lunate Facet Fracture: Thinking Outside the Box

    PubMed Central

    Harness, Neil G.

    2016-01-01

    Background Fractures of the distal radius with small volar ulnar marginal fracture fragments are difficult to stabilize with standard volar locking plates. The purpose of this study is to describe alternative techniques available to stabilize these injuries. Materials and Methods Five patients were identified retrospectively with unstable volar lunate facet fracture fragments treated with supplemental fixation techniques. The demographic data, pre- and postoperative radiographic parameters, and early outcomes data were analyzed. The AO classification, preoperative and final postoperative ulnar variance, articular step-off, volar tilt, radial inclination, and teardrop angle were measured. The lunate subsidence and length of the volar cortex available for fixation were measured from the initial injury films. Description of Technique Lunate facet fixation was based on the morphology of the fragment, and stabilization was achieved with headless compression screws in three patients, a tension band wire construct in one, and two cortical screws in another. Results Five patients with a mean age of 58 years (range: 41–82) were included. There were two AO C3.2 and three B3.3 fractures. Preoperative radiographic measurements including radial inclination, tilt, and ulnar variance all improved after surgery and were maintained within normal limits at 3-month follow-up. There was no change in the teardrop angle at final follow-up (70–64 degrees; p = 0.14). None of the patients had loss of fixation or volar carpal subluxation. The mean visual analog scale pain score at 3 months was 1 (range: 0–2). Conclusions The morphology of volar lunate facet fracture fragments is variable, and fixation must be customized to the particular pattern. Small fragments may preclude the use of plates and screws for fixation. These fractures can be managed successfully with tension band wire constructs and headless screws. These low-profile implants may decrease the risk of tendon irritation that might accompany distally placed plates. PMID:26855830

  13. Evidence of cartilage repair by joint distraction in a canine model of osteoarthritis.

    PubMed

    Wiegant, Karen; Intema, Femke; van Roermund, Peter M; Barten-van Rijbroek, Angelique D; Doornebal, Arie; Hazewinkel, Herman A W; Lafeber, Floris P J G; Mastbergen, Simon C

    2015-02-01

    Knee osteoarthritis (OA) is a degenerative joint disorder characterized by cartilage, bone, and synovial tissue changes that lead to pain and functional impairment. Joint distraction is a treatment that provides long-term improvement in pain and function accompanied by cartilage repair, as evaluated indirectly by imaging studies and measurement of biochemical markers. The purpose of this study was to evaluate cartilage tissue repair directly by histologic and biochemical assessments after joint distraction treatment. In 27 dogs, OA was induced in the right knee joint (groove model; surgical damage to the femoral cartilage). After 10 weeks of OA development, the animals were randomized to 1 of 3 groups. Two groups were fitted with an external fixator, which they wore for a subsequent 10 weeks (one group with and one without joint distraction), and the third group had no external fixation (OA control group). Pain/function was studied by force plate analysis. Cartilage integrity and chondrocyte activity of the surgically untouched tibial plateaus were analyzed 25 weeks after removal of the fixator. Changes in force plate analysis values between the different treatment groups were not conclusive. Features of OA were present in the OA control group, in contrast to the generally less severe damage after joint distraction. Those treated with joint distraction had lower macroscopic and histologic damage scores, higher proteoglycan content, better retention of newly formed proteoglycans, and less collagen damage. In the fixator group without distraction, similarly diminished joint damage was found, although it was less pronounced. Joint distraction as a treatment of experimentally induced OA results in cartilage repair activity, which corroborates the structural observations of cartilage repair indicated by surrogate markers in humans. Copyright © 2015 by the American College of Rheumatology.

  14. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable.

    PubMed

    Thorborg, Kristian; Bandholm, Thomas; Hölmich, Per

    2013-03-01

    In football, ice-hockey, and track and field, injuries have been predicted, and hip- and knee-strength deficits quantified using hand-held dynamometry (HHD). However, systematic bias exists when testers of different sex and strength perform the measurements. Belt-fixation of the dynamometer may resolve this. The aim of the present study was therefore to examine the inter-tester reliability concerning strength assessments of isometric hip abduction, adduction, flexion, extension and knee-flexion strength, using HHD with external belt-fixation. Twenty-one healthy athletes (6 women), 30 (8.6) (mean (SD)) years of age, were included. Two physiotherapy students (1 female and 1 male) performed all the measurements after careful instruction and procedure training. Isometric hip abduction, adduction, flexion, extension, and knee-flexion strength were tested. The tester-order and hip-action order were randomised. No systematic between-tester differences (bias) were observed for any of the hip or knee actions. The intra-class correlation coefficients (ICC 2.1) ranged from 0.76 to 0.95. Furthermore, standard errors of measurement in per cent (SEM %) ranged from 5 to 11 %, and minimal detectable change in per cent (MDC %) from 14 to 29 % for the different hip and knee actions. The present study shows that isometric hip- and knee-strength measurements have acceptable inter-tester reliability at the group level, when testing strong individuals, using HHD with belt-fixation. This procedure is therefore perfectly suited for the evaluation and monitoring of strong athletes with hip, groin and hamstring injuries, some of the most common and troublesome injuries in sports. Diagnostic, Level III.

  15. Rigid Posterior Lumbopelvic Fixation without Formal Debridement for Pyogenic Vertebral Diskitis and Osteomyelitis Involving the Lumbosacral Junction: Technical Report.

    PubMed

    Mazur, Marcus D; Ravindra, Vijay M; Dailey, Andrew T; McEvoy, Sara; Schmidt, Meic H

    2015-01-01

    Pelvic fixation with S2-alar-iliac (S2AI) screws can increase the rigidity of a lumbosacral construct, which may promote bone healing, improve antibiotic delivery to infected tissues, and avoid L5-S1 pseudarthrosis. To describe the use of single-stage posterior fixation without debridement for the treatment of pyogenic vertebral diskitis and osteomyelitis (PVDO) at the lumbosacral junction. Technical report. We describe the management of PVDO at the lumbosacral junction in which the infection invaded the endplates, disk space, vertebrae, prevertebral soft tissues, and epidural space. Pedicle involvement precluded screw fixation at L5. Surgical management consisted of a single-stage posterior operation with rigid lumbopelvic fixation augmented with S2-alar-iliac screws and without formal debridement of the infected area, followed by long-term antibiotic treatment. At 2-year follow-up, successful fusion and eradication of the infection were achieved. PVDO at the lumbosacral junction may be treated successfully using rigid posterior-only fixation without formal debridement combined with antibiotic therapy.

  16. Reverse Anterior Cruciate Ligament Reconstruction Fixation: A Biomechanical Comparison Study of Tibial Cross-Pin and Femoral Interference Screw Fixation.

    PubMed

    Lawley, Richard J; Klein, Samuel E; Chudik, Steven C

    2017-03-01

    To evaluate the biomechanical performance of tibial cross-pin (TCP) fixation relative to femoral cross-pin (FCP), femoral interference screw (FIS), and tibial interference screw (TIS) fixation. We randomized 40 porcine specimens (20 tibias and 20 femurs) to TIS fixation (group 1, n = 10), FIS fixation (group 2, n = 10), TCP fixation (group 3, n = 10), or FCP fixation (group 4, n = 10) and performed biomechanical testing to compare ultimate load, stiffness, yield load, cyclic displacement, and load at 5-mm displacement. We performed cross-pin fixation of the looped end and interference screw fixation of the free ends of 9-mm-diameter bovine extensor digitorum communis tendon grafts. Graft fixation constructs were cyclically loaded and then loaded to failure in line with the tunnels. Regarding yield load, FIS was superior to TIS (704 ± 125 N vs 504 ± 118 N, P = .002), TCP was superior to TIS (1,449 ± 265 N vs 504 ± 118 N, P < .001), and TCP was superior to FCP (1,449 ± 265 N vs 792 ± 397 N, P < .001). Cyclic displacement for FCP was superior to TCP. Cyclic displacement for TIS versus FIS showed no statistically significant difference (2.5 ± 1.0 mm vs 2.2 ± 0.6 mm, P = .298). Interference screw fixation consistently failed by graft slippage, whereas TCP fixation failed by tibial bone failure. FCP fixation failed by either femoral bone failure or failure elsewhere in the testing apparatus. Regarding yield load, TCP fixation performed biomechanically superior to the clinically proven FCP at time zero. Because TIS fixation shows the lowest yield strength, it represents the weak link, and combined TCP-FIS fixation theoretically would be biomechanically superior relative to combined FCP-TIS fixation with regard to yield load. Cyclic displacement showed a small difference in favor of FCP over TCP fixation and no difference between TIS and FIS. Time-zero biomechanics of TCP fixation paired with FIS fixation show that this method of fixation can be considered a potential alternative to current practice and may pose clinical benefits in different clinical scenarios of anterior cruciate ligament reconstruction. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Tibial plafond fractures: limited incision reduction with percutaneous fixation.

    PubMed

    Salton, Heather L; Rush, Shannon; Schuberth, John

    2007-01-01

    This study was a retrospective review of 18 patients with 19 pilon fractures treated with limited incision reduction and percutaneous plate fixation of the tibia. Patients were treated with either a 1- or 2-stage protocol. The latter consisted of placement of an external fixator followed by definitive reduction. The emphasis of analysis was placed on the identification of complications to the soft tissue envelope or bone-healing problems within the first 6 months after surgery. A major complication was defined as an unplanned operation within the first 6 months. Minor complications were any superficial wound defects that did not require operative intervention to resolve or any malunion or delayed union. With this protocol, no major complications were encountered. Minor complications were identified in 4 patients (4 fractures) of which 2 were minor wound problems. One patient developed a malunion, and the other had a delayed union. Four patients requested removal of prominent hardware. These results indicate that limited incision reduction and percutaneous plate fixation lead to safe methods of stabilization. The authors also provide guidance and strategies for the consistent execution of this technique.

  18. Injectable suture device for intraocular lens fixation.

    PubMed

    Smith, Jesse M; Erlanger, Michael; Olson, Jeffrey L

    2015-12-01

    We describe a surgical technique for scleral fixation of a posterior chamber intraocular lens (PC IOL) using a 24-gauge injectable polypropylene suture delivery system. A 3-piece PC IOL is inserted into the anterior chamber of the eye. Two sclerotomies are made 1.5 mm posterior to the limbus using a microvitreoretinal blade. The 24-gauge injector delivers a preformed suture loop into the eye with the double-armed needles still external to the eye. Each polypropylene IOL haptic is directed through the loop using microforceps. The suture loop is tightened around the haptic, and the attached needles are used to fixate the IOL to the sclera and close the sclerotomies simultaneously. This technique has been used in an ex vivo porcine eye and in an aphakic patient. In the latter, the IOL was quickly fixated to the sclera and maintained a stable position postoperatively. Dr. Olson has a patent pending for the device described in this article. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Detection of orthopaedic foot and ankle implants by security screening devices.

    PubMed

    Bluman, Eric M; Tankson, Cedric; Myerson, Mark S; Jeng, Clifford L

    2006-12-01

    A common question asked by patients contemplating foot and ankle surgery is whether the implants used will set off security screening devices in airports and elsewhere. Detectability of specific implants may require the orthopaedic surgeon to provide attestation regarding their presence in patients undergoing implantation of these devices. Only two studies have been published since security measures became more stringent in the post-9/11 era. None of these studies specifically focused on the large numbers of orthopaedic foot and ankle implants in use today. This study establishes empiric data on the detectability by security screening devices of some currently used foot and ankle implants. A list of foot and ankle procedures was compiled, including procedures frequently used by general orthopaedists as well as those usually performed only by foot and ankle specialists. Implants tested included those used for open reduction and internal fixation, joint fusion, joint arthroplasty, osteotomies, arthroreisis, and internal bone stimulation. A test subject walked through a gate-type security device and was subsequently screened using a wand-type detection device while wearing each construct grouping. The screening was repeated with the implants placed within uncooked steak to simulate subcutaneous and submuscular implantation. None of the implants were detected by the gate-type security device. Specific implants that triggered the wand-type detection device regardless of coverage with the meat were total ankle prostheses, implantable bone stimulators, large metatarsophalangeal hemiarthroplasty, large arthroreisis plugs, medial distal tibial locking construct, supramalleolar osteotomy fixation, stainless steel bimalleolar ankle fracture fixation, calcaneal fracture plate and screw constructs, large fragment blade plate constructs, intramedullary tibiotalocalcaneal fusion constructs, and screw fixation for calcaneal osteotomies, ankle arthrodeses, triple arthrodeses, and stainless steel first metatarsophalangeal joint arthrodeses. The placement of implants in meat prevented the detectability of only the stainless steel Jones fracture implant (stainless steel 6.5-mm cannulated screw) and the stainless steel midfoot fusion construct (four stainless steel 4.0-mm cannulated screws). These data may help the orthopaedic surgeon in counseling patients as to the detectability of some orthopaedic foot and ankle implants in use today. Specific constructs for which documentation may need to be provided to the patient are identified. As security standards evolve and the environments in which they are practiced change, empiric testing of many of these devices may need to be repeated.

  20. Dynamic locking screw improves fixation strength in osteoporotic bone: an in vitro study on an artificial bone model.

    PubMed

    Pohlemann, Tim; Gueorguiev, Boyko; Agarwal, Yash; Wahl, Dieter; Sprecher, Christoph; Schwieger, Karsten; Lenz, Mark

    2015-04-01

    The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS). Osteoporotic surrogate bones were plated with either a DLS or a LHS construct consisting of two screws and cyclically axially loaded (8,500 cycles, amplitude 420 N, increase 2 mN/cycle). Construct stiffness, relative movement, axial screw migration, proximal (P) and distal (D) screw pullout force and loosening at the bone interface were determined and statistically evaluated. DLS constructs exhibited a higher screw pullout force of P 85 N [standard deviation (SD) 21] and D 93 N (SD 12) compared with LHS (P 62 N, SD 28, p = 0.1; D 57 N, SD 25, p < 0.01) and a significantly lower axial migration over cycles compared with LHS (p = 0.01). DLS constructs showed significantly lower axial construct stiffness (403 N/mm, SD 21, p < 0.01) and a significantly higher relative movement (1.1 mm, SD 0.05, p < 0.01) compared with LHS (529 N/mm, SD 27; 0.8 mm, SD 0.04). Based on the model data, the DLS principle might also improve in vivo plate fixation in osteoporotic bone, providing enhanced residual holding strength and reducing screw cutout. The influence of pin-sleeve abutment still needs to be investigated.

  1. Biomechanical Comparison of 3 Inferiorly Directed Versus 3 Superiorly Directed Locking Screws on Stability in a 3-Part Proximal Humerus Fracture Model.

    PubMed

    Donohue, David M; Santoni, Brandon G; Stoops, T Kyle; Tanner, Gregory; Diaz, Miguel A; Mighell, Mark

    2018-06-01

    To quantify the stability of 3 points of inferiorly directed versus 3 points of superiorly directed locking screw fixation compared with the full contingent of 6 points of locked screw fixation in the treatment of a 3-part proximal humerus fracture. A standardized 3-part fracture was created in 10 matched pairs (experimental groups) and 10 nonmatched humeri (control group). Osteosynthesis was performed using 3 locking screws in the superior hemisphere of the humeral head (suspension), 3 locking screws in the inferior hemisphere (buttress), or the full complement of 6 locking screws (control). Specimens were tested in varus cantilever bending (7.5 Nm) to 10,000 cycles or failure. Construct survival (%) and the cycles to failure were compared. Seven of 10 controls survived the 10,000-cycle runout (70%: 8193 average cycles to failure). No experimental constructs survived the 10,000-cycle runout. Suspension and buttress screw groups failed an average of 331 and 516 cycles, respectively (P = 1.00). The average number of cycles to failure and the number of humeri surviving the 10,000-cycle runout were greater in the control group than in the experimental groups (P ≤ 0.006). Data support the use of a full contingent of 6 points of locking screw fixation over 3 superior or 3 inferior points of fixation in the treatment of a 3-part proximal humerus fracture with a locking construct. No biomechanical advantage to the 3 buttress or 3 suspension screws used in isolation was observed.

  2. Addition of a suture anchor for coracoclavicular fixation to a superior locking plate improves stability of type IIB distal clavicle fractures.

    PubMed

    Madsen, Wes; Yaseen, Zaneb; LaFrance, Russell; Chen, Tony; Awad, Hani; Maloney, Michael; Voloshin, Ilya

    2013-06-01

    The purpose of this study was to determine the effect of coracoclavicular (CC) fixation on biomechanical stability in type IIB distal clavicle fractures fixed with plate and screws. Twelve fresh-frozen matched cadaveric specimens were used to create type IIB distal clavicle fractures. Dual-energy x-ray absorptiometry (DEXA) scans ensured similar bone quality. Group 1 (6 specimens) was stabilized with a superior precontoured distal clavicle locking plate and supplemental suture anchor CC fixation. Group 2 (6 specimens) followed the same construct without CC fixation. Each specimen was cyclically loaded in the coronal plane at 40 to 80 N for 17,500 cycles. Load-to-failure testing was performed on the specimens that did not fail cyclic loading. Outcome measures included mode of failure and the number of cycles or load required to create 10 mm of displacement in the construct. All specimens (12 of 12) completed cyclic testing without failure and underwent load-to-failure testing. Group 1 specimens failed at a mean of 808.5 N (range, 635.4 to 952.3 N), whereas group 2 specimens failed at a mean of 401.3 N (range, 283.6 to 656.0 N) (P = .005). Group 1 specimens failed by anchor pullout without coracoid fracture (4 of 6) and distal clavicle fracture fragment fragmentation (1 of 6); one specimen did not fail at the maximal load the materials testing machine was capable of exerting (1,000 N). Group 2 specimens failed by distal clavicle fracture fragment fragmentation (3 of 6) and acromioclavicular (AC) joint displacement (1 of 6); 2 specimens did not fail at the maximal load of the materials testing machine. During cyclic loading, type IIB distal clavicle fractures with and without CC fixation remain stable. CC fixation adds stability to type IIB distal clavicle fractures fixed with plate and screws when loaded to failure. CC fixation for distal clavicle fractures is a useful adjunct to plate-and-screw fixation to augment stability of the fracture. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Malleolar fractures and their ligamentous injury equivalents have similar outcomes in supination-external rotation type IV fractures of the ankle treated by anatomical internal fixation.

    PubMed

    Berkes, M B; Little, M T M; Lazaro, L E; Sculco, P K; Cymerman, R M; Daigl, M; Helfet, D L; Lorich, D G

    2012-11-01

    It has previously been suggested that among unstable ankle fractures, the presence of a malleolar fracture is associated with a worse outcome than a corresponding ligamentous injury. However, previous studies have included heterogeneous groups of injury. The purpose of this study was to determine whether any specific pattern of bony and/or ligamentous injury among a series of supination-external rotation type IV (SER IV) ankle fractures treated with anatomical fixation was associated with a worse outcome. We analysed a prospective cohort of 108 SER IV ankle fractures with a follow-up of one year. Pre-operative radiographs and MRIs were undertaken to characterise precisely the pattern of injury. Operative treatment included fixation of all malleolar fractures. Post-operative CT was used to assess reduction. The primary and secondary outcome measures were the Foot and Ankle Outcome Score (FAOS) and the range of movement of the ankle. There were no clinically relevant differences between the four possible SER IV fracture pattern groups with regard to the FAOS or range of movement. In this population of strictly defined SER IV ankle injuries, the presence of a malleolar fracture was not associated with a significantly worse clinical outcome than its ligamentous injury counterpart. Other factors inherent to the injury and treatment may play a more important role in predicting outcome.

  4. Postoperative complications associated with external skeletal fixators in cats.

    PubMed

    Beever, Lee; Giles, Kirsty; Meeson, Richard

    2017-07-01

    The objective of this study was to quantify complications associated with external skeletal fixators (ESFs) in cats and to identify potential risk factors. A retrospective review of medical records and radiographs following ESF placement was performed. Case records of 140 cats were reviewed; fixator-associated complications (FACs) occurred in 19% of cats. The region of ESF placement was significantly associated with complication development. Complications developed most frequently in the femur (50%), tarsus (35%) and radius/ulna (33%). Superficial pin tract infection (SPTI) and implant failure accounted for 45% and 41% of all FACs, respectively. SPTI occurred more frequently in the femur, humerus and tibia, with implant failure more frequent in the tarsus. No association between breed, age, sex, weight, fracture type (open vs closed), ESF classification, number of pins per bone segment, degree of fracture load sharing, and the incidence or type of FAC was identified. No association between region of placement, breed, age, sex, weight, fracture type (open vs closed), ESF classification, number of pins per bone segment, fracture load sharing and the time to complication development was identified. Complication development is not uncommon in cats following ESF placement. The higher complication rate in the femur, tarsus and radius/ulna should be considered when reviewing options for fracture management. However, cats appear to have a lower rate of pin tract infections than dogs.

  5. Limb lengthening in short-stature patients using monolateral and circular external fixators.

    PubMed

    Lie, Chester W H; Chow, W

    2009-08-01

    To review the results of distraction osteogenesis in short-stature patients in our centre and analyse outcomes including complications. Retrospective study. University teaching hospital, Hong Kong. Eight patients with short stature (three had achondroplasia, three constitutional short stature, and two hypochondroplasia) operated on for limb lengthening using monolateral or circular external fixators between 1995 and 2006 were reviewed. The mean age at the time of surgery was 20 years (range, 9-39 years). The fixators used were either Ilizarov or Orthofix. The average gain in length per bone segment was 5.2 cm (range, 3.2-8.0 cm), and the average percentage lengthening was 21% (range, 7.9-40%). The mean time in frame was 8 months (range, 4-14 months), and the average healing index was 48 days per cm of lengthening (18-110 days per cm). Minor complications (pin tract infection and transient joint stiffness) were common, and after excluding the latter the overall complication rate was 0.6 per bone segment. In our series, limb lengthening of up to 40% of the initial length of the bone segment can be achieved without significant long-term sequelae. However, the procedures were complex and prolonged, and required a special psychological approach directed at both parents and the patients. Complications are quite common, for which patients have to be well prepared before starting the procedures.

  6. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.

    PubMed

    Hoffmann, Martin F; Burgers, Travis A; Mason, James J; Williams, Bart O; Sietsema, Debra L; Jones, Clifford B

    2014-07-01

    In the United States there are more than 230,000 total hip replacements annually, and periprosthetic femoral fractures occur in 0.1-4.5% of those patients. The majority of these fractures occur at the tip of the stem (Vancouver type B1). The purpose of this study was to compare the biomechanically stability and strength of three fixation constructs and identify the most desirable construct. Fifteen medium adult synthetic femurs were implanted with a hip prosthesis and were osteotomized in an oblique plane at the level of the implant tip to simulate a Vancouver type B1 periprosthetic fracture. Fractures were fixed with a non-contact bridging periprosthetic proximal femur plate (Zimmer Inc., Warsaw, IN). Three proximal fixation methods were used: Group 1, bicortical screws; Group 2, unicortical screws and one cerclage cable; and Group 3, three cerclage cables. Distally, all groups had bicortical screws. Biomechanical testing was performed using an axial-torsional testing machine in three different loading modalities (axial compression, lateral bending, and torsional/sagittal bending), next in axial cyclic loading to 10,000 cycles, again in the three loading modalities, and finally to failure in torsional/sagittal bending. Group 1 had significantly greater load to failure and was significantly stiffer in torsional/sagittal bending than Groups 2 and 3. After cyclic loading, Group 2 had significantly greater axial stiffness than Groups 1 and 3. There was no difference between the three groups in lateral bending stiffness. The average energy absorbed during cyclic loading was significantly lower in Group 2 than in Groups 1 and 3. Bicortical screw placement achieved the highest load to failure and the highest torsional/sagittal bending stiffness. Additional unicortical screws improved axial stiffness when using cable fixation. Lateral bending was not influenced by differences in proximal fixation. To treat periprosthetic fractures, bicortical screw placement should be attempted to maximize load to failure and torsional/sagittal bending stiffness. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Outcome of 28 open pilon fractures with injury severity-based fixation.

    PubMed

    Danoff, Jonathan R; Saifi, Comron; Goodspeed, David C; Reid, J Spence

    2015-04-01

    Open pilon fracture management and treatment poses a significant challenge to orthopedic surgeons. The purpose of this study was to determine patient outcomes for open pilon fractures based on wound complication and infection rates, as well as subjective outcome instruments. This was a retrospective consecutive case series of 28 fractures with Orthopaedic Trauma Association (OTA)-type 43-B and 43-C open pilon fractures. Mean length of follow-up was 36 months and minimum of 1 year. Ten fractures were Gustilo and Anderson grade IIIB, and the remaining fractures were grades I-IIIA. Patients were initially treated with spanning external fixation and staged wound debridement followed by osteosynthesis of the articular surface. Metaphyseal fixation was by either plate fixation or Ilizarov frame. The primary outcome was the incidence of deep tissue infection requiring surgery. Secondary outcomes included the incidence of other complications (nonunion, malunion, amputation) and functional outcomes (Short Musculoskeletal Functional Assessment Questionnaire and AAOS Foot and Ankle Questionnaire). Four patients developed deep tissue infections, three in the internal fixation group and one in the Ilizarov group, and all were treated successfully with staged debridement. There were two delayed unions required bone grafting, and infection-free union was ultimately achieved in all fractures. Two patients underwent arthrodesis secondary to post-traumatic arthritis, while no patients experienced malunions or amputations. The use of staged wound debridement in conjunction with either plate fixation or Ilizarov frame achieves low rates of wound infection and stable fixation after anatomic joint reconstruction for OTA-type 43-B and 43-C open pilon fractures.

  8. [Unstable thorax fixation with bioabsorbable plates and screws. Presentation of some cases].

    PubMed

    Nolasco-de la Rosa, Ana Lilia; Mosiñoz-Montes, Roberto; Matehuala-García, Jesús; Román-Guzmán, Edgardo; Quero-Sandoval, Fidel; Reyes-Miranda, Alma Lorena

    2015-01-01

    Flail chest is managed with mechanical ventilation or inhalation therapy, and analgesia. Mechanical ventilations carry risks by themselves and disengage with the external fixators so they must be operated to improve lung ventilatory mechanics and cleaning. Little has been published on the use of bioabsorbable material and its evolution in the setting of flail chest. A material that did had to be retired, that presented the malleability of titanium and its inflammatory reaction was minimal and could be handled in both adults and children was investigated. Here is shown a descriptive study of patients with flail chest under rib fixation with plates and bioabsorbable screws. 18 cases are presented, aged 33-74 years, three with bilateral flail chest; fixation was performed between days 1-21 of the accident. In cases that showed no fractures pelvic limbs, gait next day restarted fi ng in all cases improved mechanical ventilation, pain decreased, none has so far presented reaction material. Flail chest has a high (16.3%) mortality when no management provides the pathophysiology of the condition (pain, poor mechanical ventilation, alveolar edema-pulmonary contusion). The use of bioabsorbable material has no side effects attributable to material which is another option for rib fixation. Copyright © 2015. Published by Masson Doyma México S.A.

  9. [Clinical randomized controlled trial on ultrashort wave and magnetic therapy for the treatment of early stage distal radius fractures].

    PubMed

    Wang, Guan-Jie; Liu, Jia

    2012-07-01

    To explore the effect of application of ultrashort wave and magnetic therapy instrument on the swelling regression in distal radius fractures treated by splint external fixation in initial stage. From March 2007 to May 2010,90 patients with distal radial fracture were treated by manual reduction and splint external fixation. After manual reduction and small splints external fixation, these patients were randomly divided into electrical physical therapy group, western medicine group and the control group by the order of calling number, with 30 cases each group. In control group, there were 9 males and 21 females with an average age of (61.29 +/- 1.97) years, the patients raised and exercise the limb and fingers only. The other two groups also carried out this treatment. In electrical physical therapy group, there were 9 males and 21 females with an average age of (62.37 +/- 2.48) years, the patients were treated with ultrashort wave and magnetic therapy instrument for early intervention, once a day, 5 days for a course of treatment and three cycle were operated. In western medicine group,there were 8 males and 22 females with an average age of (60.12 +/- 2.87) years, the patients were injected with beta-aescin (20 mg, intravenous injection,once a day) for 5 days, followed by Danshen injection (20 ml, intravenous injection, once a day) for 10 days. The limb swelling of patients were assessed every day for 20 days after manual reduction and small splints external fixation. The time of swelling regression in electrical physical therapy group, western medicine group and the control group were respectively (9.62 +/- 3.32), (10.05 +/- 3.05) and (14.57 +/- 2.93) days. Both of that in electrical physical therapy group and western medicine group were shorter than that in the control group (P<0.05), then there were not statistical difference between electrical physical therapy group and western medicine group (P>0.05). The effective rate of swelling regression in electrical physical therapy group, western medicine group and the control group were 86.67%, 80.00%, 46.66% respectively. There was no significant differences between electrical physical therapy group and western medicine group in the curative effect, but both of them had advantage over the control group. Application of ultrashort wave and magnetic therapy instrument for treatment of distal radial fractures in initial stage can promote the regression of limb swelling evidently, which is similar to the intravenous infusion of beta-aescin injection and Danshen injection in curative effect.

  10. [Early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect].

    PubMed

    Xiao, Jian; Mao, Zhao-Guang; Zhu, Hui-Hua; Guo, Liang

    2017-03-25

    To discuss the curative effect of the early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect. From December 2013 to January 2015, 36 cases of lower limb open comminuted fractures complicated with bone defects were treated by the vancomycin ALBC combined with the external fixation support, including 26 males and 10 females with an average age of 38.0 years old ranging from 19 to 65 years old. The included cases were all open fractures of lower limbs complicated with bone defects with different degree of soft tissue injuries. Among them, 25 cases were tibial fractures, 11 cases were femoral fractures. The radiographs indicated a presence of bone defects, which ranged from 3.0 to 6.1 cm with an average of 4.0 cm. The Gustilo classification of open fractures:24 cases were type IIIA, 12 cases were typr IIIB. The percentage of wound infection, bone grafting time, fracture healing time and postoperative joint function of lower limb were observed. The function of injured limbs was evaluated at 1 month after the clinical healing of fracture based on Paley evaluation criterion. All cases were followed up for 3 to 24 months with an average of (6.0±3.0) months. The wound surface was healed well, neither bone infections nor unhealed bone defects were presented. The reoperation of bone grafting was done at 6 weeks after the patients received an early treatment with ALBC, some of them were postponed to 8 weeks till the approximate healing of fractures, the treatment course lasted for 4 to 8 months with an average of(5.5±1.5) months. According to Paley and other grading evaluations of bone and function, there were 27 cases as excellent, 5 cases as good, 3 cases as ordinary. The ALBC combined with external fixation support was an effective method for early treatment to treat the traumatic lower limb open fractures complicated with bone defects. This method was typified with the advantages such as easy operation, short operation time, overwhelming superiority in controlling infection and provision of good bone grafting bed, a good bone healing can be realized by the use of membrane induction technology for bone grafting.

  11. Eye gaze during comprehension of American Sign Language by native and beginning signers.

    PubMed

    Emmorey, Karen; Thompson, Robin; Colvin, Rachael

    2009-01-01

    An eye-tracking experiment investigated where deaf native signers (N = 9) and hearing beginning signers (N = 10) look while comprehending a short narrative and a spatial description in American Sign Language produced live by a fluent signer. Both groups fixated primarily on the signer's face (more than 80% of the time) but differed with respect to fixation location. Beginning signers fixated on or near the signer's mouth, perhaps to better perceive English mouthing, whereas native signers tended to fixate on or near the eyes. Beginning signers shifted gaze away from the signer's face more frequently than native signers, but the pattern of gaze shifts was similar for both groups. When a shift in gaze occurred, the sign narrator was almost always looking at his or her hands and was most often producing a classifier construction. We conclude that joint visual attention and attention to mouthing (for beginning signers), rather than linguistic complexity or processing load, affect gaze fixation patterns during sign language comprehension.

  12. The fixation strength of tibial PCL press-fit reconstructions.

    PubMed

    Ettinger, M; Wehrhahn, T; Petri, M; Liodakis, E; Olender, G; Albrecht, U-V; Hurschler, C; Krettek, C; Jagodzinski, M

    2012-02-01

    A secure tibial press-fit technique in posterior cruciate ligament reconstructions is an interesting technique because no hardware is necessary. For anterior cruciate ligament (ACL) reconstruction, a few press-fit procedures have been published. Up to the present point, no biomechanical data exist for a tibial press-fit posterior cruciate ligament (PCL) reconstruction. The purpose of this study was to characterize a press-fit procedure for PCL reconstruction that is biomechanically equivalent to an interference screw fixation. Quadriceps and hamstring tendons of 20 human cadavers (age: 49.2 ± 18.5 years) were used. A press-fit fixation with a knot in the semitendinosus tendon (K) and a quadriceps tendon bone block graft (Q) were compared to an interference screw fixation (I) in 30 porcine femora. In each group, nine constructs were cyclically stretched and then loaded until failure. Maximum load to failure, stiffness, and elongation during failure testing and cyclical loading were investigated. The maximum load to failure was 518 ± 157 N (387-650 N) for the (K) group, 558 ± 119 N (466-650 N) for the (I) group, and 620 ± 102 N (541-699 N) for the (Q) group. The stiffness was 55 ± 27 N/mm (18-89 N/mm) for the (K) group, 117 ± 62 N/mm (69-165 N/mm) for the (I) group, and 65 ± 21 N/mm (49-82 N/mm) for the (Q) group. The stiffness of the (I) group was significantly larger (P = 0.01). The elongation during cyclical loading was significantly larger for all groups from the 1st to the 5th cycle compared to the elongation in between the 5th to the 20th cycle (P < 0.03). All techniques exhibited larger elongation during initial loading. Load to failure and stiffness was significantly different between the fixations. The Q fixation showed equal biomechanical properties compared to a pure tendon fixation (I) with an interference screw. All three fixation techniques that were investigated exhibit comparable biomechanical properties. Preconditioning of the constructs is critical. Clinical trials have to investigate the biological effectiveness of these fixation techniques.

  13. Surgical treatment of intra-articular calcaneal fractures.

    PubMed

    Stapleton, John J; Zgonis, Thomas

    2014-10-01

    Most intra-articular calcaneal fractures are a result of high-energy trauma. The operative management of calcaneal fractures has been based on achieving anatomic reduction and minimizing complications of the compromised soft tissue envelope. The traditional extensile lateral approach offers advantages of achieving adequate fracture reduction with the risk of wound-healing complications and infection. Limited open reduction and internal fixation techniques with or without using external fixation focuses on achieving fracture reduction with less risk of wound complications but higher risk of malunion. This article discusses key points of operative management for various intra-articular calcaneal fracture patterns and clinical presentations. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. A Biomechanical Analysis of 2 Constructs for Metacarpal Spiral Fracture Fixation in a Cadaver Model: 2 Large Screws Versus 3 Small Screws.

    PubMed

    Eu-Jin Cheah, Andre; Behn, Anthony W; Comer, Garet; Yao, Jeffrey

    2017-12-01

    Surgeons confronted with a long spiral metacarpal fracture may choose to fix it solely with lagged screws. A biomechanical analysis of a metacarpal spiral fracture model was performed to determine whether 3 1.5-mm screws or 2 2.0-mm screws provided more stability during bending and torsional loading. Second and third metacarpals were harvested from 12 matched pairs of fresh-frozen cadaveric hands and spiral fractures were created. One specimen from each matched pair was fixed with 2 2.0-mm lagged screws whereas the other was fixed with 3 1.5-mm lagged screws. Nine pairs underwent combined cyclic cantilever bending and axial compressive loading followed by loading to failure. Nine additional pairs were subjected to cyclic external rotation while under a constant axial compressive load and were subsequently externally rotated to failure under a constant axial compressive load. Paired t tests were used to compare cyclic creep, stiffness, displacement, rotation, and peak load levels. Average failure torque for all specimens was 7.2 ± 1.7 Nm. In cyclic torsional testing, the group with 2 screws exhibited significantly less rotational creep than the one with 3 screws. A single specimen in the group with 2 screws failed before cyclic bending tests were completed. No other significant differences were found between test groups during torsional or bending tests. Both constructs were biomechanically similar except that the construct with 2 screws displayed significantly less loosening during torsional cyclic loading, although the difference was small and may not be clinically meaningful. Because we found no obvious biomechanical advantage to using 3 1.5-mm lagged screws to fix long spiral metacarpal fractures, the time efficiency and decreased implant costs of using 2-2.0 mm lagged screws may be preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Is fibular fracture displacement consistent with tibiotalar displacement?

    PubMed

    van den Bekerom, Michel P J; van Dijk, C Niek

    2010-04-01

    We believed open reduction with internal fixation is required for supination-external rotation ankle fractures located at the level of the distal tibiofibular syndesmosis (Lauge-Hanssen SER II and Weber B) with 2 mm or more fibular fracture displacement. The rationale for surgery for these ankle fractures is based on the notion of elevated intraarticular contact pressures with lateral displacement. To diagnose these injuries, we presumed that in patients with a fibular fracture with at least 2 mm fracture displacement, the lateral malleolus and talus have moved at least 2 mm in a lateral direction without medial displacement of the proximal fibula. We reviewed 55 adult patients treated operatively for a supination-external rotation II ankle fracture (2 mm or more fibular fracture displacement) between 1990 and 1998. On standard radiographs, distance from the tibia to the proximal fibula, distance from the tibia to the distal fibula, and displacement at the level of the fibular fracture were measured. These distances were compared preoperatively and postoperatively. We concluded tibiotalar displacement cannot be reliably assessed at the level of the fracture. Based on this and other studies, we believe there is little evidence to perform open reduction and internal fixation of supination-external rotation II ankle fractures. Level IV, case series. See Guidelines for Authors for a complete description of levels of evidence.

  16. Removable splint with locking attachments for maxillary distraction osteogenesis with the RED system.

    PubMed

    Suzuki, E Y; Suzuki, B

    2007-12-01

    The external traction hooks of the intraoral splint used to control traction forces applied to the maxilla with the rigid external distraction system represent a major barrier to surgical procedures. The purpose of this article is to introduce a removable intraoral splint with locking attachments that can be placed post-surgically immediately before distraction, facilitating surgery and consequently reducing the operative time. Fifteen cleft lip and palate patients underwent maxillary distraction osteogenesis using a rigid external distraction device in combination with the proposed removable splint that was fixed onto the maxillary teeth to provide anchorage. Initial records showed severe maxillary hypoplasia and negative overjet. The removable splint was fabricated using 1.5-mm diameter stainless-steel rigid orthodontic wires soldered to the locking attachments (Y&B Products LP, Chiang Mai, Thailand), making possible its placement post-surgically. Stable splint fixation was achieved prior to the distraction procedure and the desired treatment goals were reached. No complications inserting or removing the splint post-surgically, including pain or discomfort, were observed. The use of the removable splint with locking attachments has proved to be a highly effective fixation approach to manage the severely hypoplastic maxilla, eliminating lip constraints resulting from scarring, and allowing for easier, more deliberate and careful dissection.

  17. Biomechanical analysis of posteromedial tibial plateau split fracture fixation.

    PubMed

    Zeng, Zhi-Min; Luo, Cong-Feng; Putnis, Sven; Zeng, Bing-Fang

    2011-01-01

    The purpose of this study was to compare the biomechanical strength of four different fixation methods for a posteromedial tibial plateau split fracture. Twenty-eight tibial plateau fractures were simulated using right-sided synthetic tibiae models. Each fracture model was randomly instrumented with one of the four following constructs, anteroposterior lag-screws, an anteromedial limited contact dynamic compression plate (LC-DCP), a lateral locking plate, or a posterior T-shaped buttress plate. Vertical subsidence of the posteromedial fragment was measured from 500 N to 1500 N during biomechanical testing, the maximum load to failure was also determined. It was found that the posterior T-shaped buttress plate allowed the least subsidence of the posteromedial fragment and produced the highest mean failure load than each of the other three constructs (P=0.00). There was no statistical significant difference between using lag screws or an anteromedial LC-DCP construct for the vertical subsidence at a 1500 N load and the load to failure (P>0.05). This study showed that a posterior-based buttress technique is biomechanically the most stable in-vitro fixation method for posteromedial split tibial plateau fractures, with AP screws and anteromedial-based LC-DCP are not as stable for this type of fracture. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Nitrogen limitation on land: how can it occur in Earth system models?

    PubMed

    Thomas, R Quinn; Brookshire, E N Jack; Gerber, Stefan

    2015-05-01

    The representation of the nitrogen (N) cycle in Earth system models (ESMs) is strongly motivated by the constraint N poses on the sequestration of anthropogenic carbon (C). Models typically implement a stoichiometric relationship between C and N in which external supply and assimilation by organisms are adjusted to maintain their internal stoichiometry. N limitation of primary productivity thus occurs if the N supply from uptake and fixation cannot keep up with the construction of tissues allowed by C assimilation. This basic approach, however, presents considerable challenges in how to faithfully represent N limitation. Here, we review how N limitation is currently implemented and evaluated in ESMs and highlight challenges and opportunities in their future development. At or near steady state, N limitation is governed by the magnitude of losses from the plant-unavailable pool vs. N fixation and there are considerable differences in how models treat both processes. In nonsteady-state systems, the accumulation of N in pools with slow turnover rates reduces N available for plant uptake and can be challenging to represent when initializing ESM simulations. Transactional N limitation occurs when N is incorporated into various vegetation and soil pools and becomes available to plants only after it is mineralized, the dynamics of which depends on how ESMs represent decomposition processes in soils. Other challenges for ESMs emerge when considering seasonal to interannual climatic oscillations as they create asynchronies between C and N demand, leading to transient alternations between N surplus and deficit. Proper evaluation of N dynamics in ESMs requires conceptual understanding of the main levers that trigger N limitation, and we highlight key measurements and observations that can help constrain these levers. Two of the biggest challenges are the mechanistic representation of plant controls on N availability and turnover, including N fixation and organic matter decomposition processes. © 2015 John Wiley & Sons Ltd.

  19. Techniques in the management of juxta-articular aggressive and recurrent giant cell tumors around the knee.

    PubMed

    Vidyadhara, S; Rao, S K

    2007-03-01

    Juxta-articular aggressive and recurrent giant cell tumors around the knee pose difficulties in management. This article reviews current problems and options in the management of these giant cell tumors. A systematic search was performed on juxta-articular aggressive and recurrent giant cell tumor. Additional information was retrieved from hand searching the literature and from relevant congress proceedings. We addressed the following issues: general consensus on early diagnosis and techniques in its management. In particular, we describe our results with resection arthrodesis performed combining the benefits of both interlocking intramedullary nail and Ilizarov fixator in the management of these tumors around the knee. Mean operative age of the 22 patients undergoing resection arthrodesis was 35.63 years. Seven lesions were in the tibia and fifteen in the femur. Mean length of the bone defect was 12.34 cm. The mean external fixator index was 7.44 days/cm and the distraction index was 7.88 days/cm. Mean period of follow-up for the patients was 64.5 months. The function of the affected limb was rated excellent in 10 and good and fair in six patients each as per Enneking criteria. No local recurrence of tumor was seen. Seven complications occurred in five patients. Two-ring construct, bifocal bone transport, and early definite plate osteosynthesis with additional bone grafting of the docking site at the end of distraction even before consolidation of the regenerate helps to reduce the problems of pin tract infections drastically. Thin-diameter long intramedullary nail in addition to preserving the endosteal blood supply also prevents mal-alignment of the regenerate. Thus resection arthrodesis using interlocking intramedullary nail and bone transport using Ilizarov fixator is cost effective and effective in achieving the desired goals of reconstruction with least complications in selected patients with specific indications.

  20. [Surgical treatment of pronation and supination external rotation trimalleolar fractures].

    PubMed

    Xu, Ye-qing; Zhan, Bei-lei; He, Fei-xiong; Wei, Hong-da

    2008-04-01

    To explore the operative method and its clinical effects of pronation and supination external rotation trimalleolar fractures. From March 2000 to July 2006,42 patients of the pronation and supination external rotation trimalleolar fractures treated with open reduction and internal fixation. Thirty-one were males and 11 were females,with an average age of 40.5 years (from 19 to 76 years). Four cases were open fractures and 38 cases close fractures. The fractures were classified as pronation-external rotation (grade IV) injury in 18 cases and supination-external rotation (grade IV)in 24 cases according to the system of Lauge-Hansen. The time of injury to operation was 2 hours to 27 days. The medial, lateral and posterior malleolus were exposed by standard anteromedial and Gatellier-Chastang approaches. The reduction and internal fixation started with the posterior,then the medial and the lateral malleolus and distal tibiofibular syndesmosis in sequence. The anteroposterior, lateral and mostise X-ray films were taken after operation. All the patients were followed up for an average time of 13.5 months(from 6 to 24 months). The time of union was from 12 to 16 weeks. The results were excellent in 20,good in 16, fair in 4 and poor in 2 cases according to Baird-Jackson ankle scoring system based on pain, stability, walking ability,range of motion and radiological manifestations. The excellent and good rate was 85.7%. There were no infection,malunion and nonunion of the fractures except that the inserted screw to distal tibiofibular syndesmosis was broken in 1 case. The key of operative treatment is to restore the anatomy of ankle and to regain the ankle function maximally.

  1. Reconstruction of the lateral tibia plateau fracture with a third triangular support screw: A biomechanical study.

    PubMed

    Moran, Eduardo; Zderic, Ivan; Klos, Kajetan; Simons, Paul; Triana, Miguel; Richards, R Geoff; Gueorguiev, Boyko; Lenz, Mark

    2017-10-01

    Split fractures of the lateral tibia plateau in young patients with good bone quality are commonly treated using two minimally invasive percutaneous lag screws, followed by unloading of the knee joint. Improved stability could be achieved with the use of a third screw inserted either in the jail-technique fashion or with a triangular support screw configuration. The aim of this study was to investigate under cyclic loading the compliance and endurance of the triangular support fixation in comparison with the standard two lag-screw fixation and the jail technique. Lateral split fractures of type AO/OTA 41-B1 were created on 21 synthetic tibiae and subsequently fixed with one of the following three techniques for seven specimens: standard fixation by inserting two partially threaded 6.5 mm cannulated lag screws parallel to each other and orthogonal to the fracture plane; triangular support fixation-standard fixation with one additional support screw at the distal end of the fracture at 30° proximal inclination; and jail fixation-standard fixation with one additional orthogonal support screw inserted in the medial nonfractured part of the bone. Mechanical testing was performed under progressively increasing cyclic compression loading. Fragment displacement was registered via triggered radiographic imaging. Mean construct compliance was 3.847 × 10 -3  mm/N [standard deviation (SD) 0.784] for standard fixation, 3.838 × 10 -3  mm/N (SD 0.242) for triangular fixation, and 3.563 × 10 -3  mm/N (SD 0.383) for jail fixation, with no significant differences between the groups ( p  = 0.525). The mean numbers of cycles to 2 mm fragment dislocation, defined as a failure criterion, were 12,384 (SD 2267) for standard fixation, 17,708 (SD 2193) for triangular fixation, and 14,629 (SD 5194) for jail fixation. Triangular fixation revealed significantly longer endurance than the standard one ( p  = 0.047). Triangular support fixation enhanced interfragmentary stability at the ultimate stage of dynamic loading. However, the level of improvement seems to be limited and may not legitimate the intervention with an additional third screw.

  2. Fracture reduction and primary ankle arthrodesis: a reliable approach for severely comminuted tibial pilon fracture.

    PubMed

    Beaman, Douglas N; Gellman, Richard

    2014-12-01

    Posttraumatic arthritis and prolonged recovery are typical after a severely comminuted tibial pilon fracture, and ankle arthrodesis is a common salvage procedure. However, few reports discuss the option of immediate arthrodesis, which may be a potentially viable approach to accelerate overall recovery in patients with severe fracture patterns. (1) How long does it take the fracture to heal and the arthrodesis to fuse when primary ankle arthrodesis is a component of initial fracture management? (2) How do these patients fare clinically in terms of modified American Orthopaedic Foot and Ankle Society (AOFAS) scores and activity levels after this treatment? (3) Does primary ankle arthrodesis heal in an acceptable position when anterior ankle arthrodesis plates are used? During a 2-year period, we performed open fracture reduction and internal fixation in 63 patients. Eleven patients (12 ankles) with severely comminuted high-energy tibial pilon fractures were retrospectively reviewed after surgical treatment with primary ankle arthrodesis and fracture reduction. Average patient age was 58 years, and minimum followup was 6 months (average, 14 months; range, 6-22 months). Anatomically designed anterior ankle arthrodesis plates were used in 10 ankles. Ring external fixation was used in nine ankles with concomitant tibia fracture or in instances requiring additional fixation. Clinical evaluation included chart review, interview, the AOFAS ankle-hindfoot score, and radiographic evaluation. All of the ankle arthrodeses healed at an average of 4.4 months (range, 3-5 months). One patient had a nonunion at the metaphyseal fracture, which healed with revision surgery. The average AOFAS ankle-hindfoot score was 83 with 88% having an excellent or good result. Radiographic and clinical analysis confirmed a plantigrade foot without malalignment. No patients required revision surgery for malunion. Primary ankle arthrodesis combined with fracture reduction for the severely comminuted tibial pilon fracture reliably healed and restored acceptable function in this highly selective patient group. Ring external fixation may be a useful adjunct to internal fixation, and this concept should be further studied. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  3. Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol.

    PubMed

    Raduan Neto, Jorge; de Moraes, Vinicius Ynoe; Gomes Dos Santos, João B; Faloppa, Flávio; Belloti, João Carlos

    2014-03-05

    Various treatments are available for reducible unstable fractures of the distal radius, such as closed reduction combined with fixation by external fixator (EF), and rigid internal fixation using a locked volar plate (VP). Although there are studies comparing these methods, there is no conclusive evidence indicating which treatment is best. The hypothesis of this study is that surgical treatment with a VP is more effective than EF from the standpoint of functional outcome (patient-reported). The study is randomized clinical trial with parallel groups and a blinded evaluator and involves the surgical interventions EF and VP. Patients will be randomly assigned (assignment ratio 1:1) using sealed opaque envelopes. This trial will include consecutive adult patients with an acute (up to 15 days) displaced, unstable fracture of the distal end of the radius of type A2, A3, C1, C2 or C3 by the Arbeitsgemeinschaft für Osteosynthesefragen-Association for the Study of Internal Fixation classification and type II or type III by the IDEAL32 classification, without previous surgical treatments of the wrist. The surgical intervention assigned will be performed by three surgical specialists familiar with the techniques described. Evaluations will be performed at 2, and 8 weeks, 3, 6 and 12 months, with the primary outcomes being measured by the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and measurement of pain (Visual Analog Pain Scale and digital algometer). Secondary outcomes will include radiographic parameters, objective functional evaluation (goniometry and dynamometry), and the rate of complications and method failure according to the intention-to-treat principle. Final postoperative evaluations (6 and 12 months) will be performed by independent blinded evaluators. For the Student's t-test, a difference of 10 points in the DASH score, with a 95% confidence interval, a statistical power of 80%, and 20% sampling error results in 36 patients per group. Results from this study protocol will improve the current evidence regarding to the surgical treatment these fractures. ISCRTN09599740.

  4. Incidence and risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture: A systematic review and meta-analysis.

    PubMed

    Shao, Jiashen; Chang, Hengrui; Zhu, Yanbin; Chen, Wei; Zheng, Zhanle; Zhang, Huixin; Zhang, Yingze

    2017-05-01

    This study aimed to quantitatively summarize the risk factors associated with surgical site infection after open reduction and internal fixation of tibial plateau fracture. Medline, Embase, CNKI, Wanfang database and Cochrane central database were searched for relevant original studies from database inception to October 2016. Eligible studies had to meet quality assessment criteria according to the Newcastle-Ottawa Scale, and had to evaluate the risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture. Stata 11.0 software was used for this meta-analysis. Eight studies involving 2214 cases of tibial plateau fracture treated by open reduction and internal fixation and 219 cases of surgical site infection were included in this meta-analysis. The following parameters were identified as significant risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture (p < 0.05): open fracture (OR 3.78; 95% CI 2.71-5.27), compartment syndrome (OR 3.53; 95% CI 2.13-5.86), operative time (OR 2.15; 95% CI 1.53-3.02), tobacco use (OR 2.13; 95% CI 1.13-3.99), and external fixation (OR 2.07; 95% CI 1.05-4.09). Other factors, including male sex, were not identified as risk factors for surgical site infection. Patients with the abovementioned medical conditions are at risk of surgical site infection after open reduction and internal fixation of tibial plateau fracture. Surgeons should be cognizant of these risks and give relevant preoperative advice. Copyright © 2017. Published by Elsevier Ltd.

  5. Bacterial N2-fixation in mangrove ecosystems: insights from a diazotroph-mangrove interaction.

    PubMed

    Alfaro-Espinoza, Gabriela; Ullrich, Matthias S

    2015-01-01

    Mangrove forests are highly productive ecosystems but represent low nutrient environments. Nitrogen availability is one of the main factors limiting mangrove growth. Diazotrophs have been identified as key organisms that provide nitrogen to these environments. N2-fixation by such organisms was found to be higher in the mangrove roots than in surrounding rhizosphere. Moreover, previous studies showed that mangroves grew better in the presence of N2-fixers indicating a potentially mutualistic relationship. However, the molecular signals and mechanisms that govern these interactions are still poorly understood. Here we present novel insights in the interaction of a diazotroph with a mangrove species to improve our understanding of the molecular and ecophysiological relationship between these two organisms under controlled conditions. Our results showed that Marinobacterium mangrovicola is a versatile organism capable of competing with other organisms to survive for long periods in mangrove soils. N2-fixation by this bacterium was up-regulated in the presence of mangrove roots, indicating a possible beneficial interaction. The increase in N2-fixation was limited to cells of the exponential growth phase suggesting that N2-fixation differs over the bacterial growth cycle. Bacterial transformants harboring a transcriptional nifH::gusA fusion showed that M. mangrovicola successfully colonized mangrove roots and simultaneously conducted N2-fixation. The colonization process was stimulated by the lack of an external carbon source suggesting a possible mutualistic relationship. M. mangrovicola represents an interesting genetically accessible diazotroph, which colonize mangrove roots and exhibit higher N2-fixation in the presence of mangrove roots. Consequently, we propose this microorganism as a tool to study molecular interactions between N2-fixers and mangrove plants and to better understand how changes in the environment could impact these important and relatively unknown interactions.

  6. Optimal Treatment of Malignant Long Bone Fracture: Influence of Method of Repair and External Beam Irradiation on the Pathway and Efficacy of Fracture Healing

    DTIC Science & Technology

    2015-10-01

    stiffness, or a partial snap with lower yield force and stiffness (Figure 4). Three dimensional micro CT analysis around fracture Figure 3. (a-b... fractures with plate fixation on both sides and irradiation on the left while the contralateral limb serves as a non-radiated internal control. The...AWARD NUMBER: W81XWH-13-1-0430 TITLE: Optimal Treatment of Malignant Long Bone Fracture : Influence of Method of Repair and External Beam

  7. Fixation of osteoporotic fractures in the upper limb with a locking compression plate.

    PubMed

    Neuhaus, V; King, J D; Jupiter, J B

    2012-01-01

    Locking Compression Plate (LCP) has the advantageous feature that screws can be locked in the plate leaving an angular stable construct. There is no need to have contact between the plate and the bone to achieve stability resulting from friction of the plate-bone-construct. Therefore the plate does not need to be contoured exactly to the bone and the healing bone's periosteal blood supply is not affected. The LCP is used as a bridging plate to gain relative stability in multi-fragmentary, diaphyseal or metaphyseal fractures. Depending on the fracture, the combination hole can also allow the LCP to achieve absolute stability similar to conventional fixation techniques. Osteoporotic fractures have significant impact on morbidity and mortality. Proximal humeral and distal radius fractures are typical examples. These osteoporotic and often comminuted fractures are ideal settings/indications for LCP utilization in the upper extremity. However, the data quality is due to mostly small study populations not so powerful. Unquestionably there has been a clear and fashionable trend to choose operative treatment for these fractures, because the angular stability allows stable fixation and early functional mobilization.

  8. Quantifying the competing relationship between adduction range of motion and baseplate micromotion with lateralization of reverse total shoulder arthroplasty.

    PubMed

    Elwell, Josie; Choi, Joseph; Willing, Ryan

    2017-02-08

    Lateralizing the center of rotation (COR) of reverse total shoulder arthroplasty (rTSA) could improve functional outcomes and mitigate scapular notching, a commonly occurring complication of the procedure. However, resulting increases in torque at the bone-implant interface may negatively affect initial fixation of the glenoid-side component, especially if only two fixation screws can be placed. Shoulder-specific finite element (FE) models of four fresh-frozen cadaveric shoulders were constructed. Scapular geometry and material property distributions were derived from CT data. Generic baseplates with two and four fixation screws were virtually implanted, after which superiorly-oriented shear loads, accompanied by a compressive load, were applied incrementally further from the glenoid surface to simulate lateralization of the COR. Relationships between lateralization, adduction range of motion (ROM), the number of fixation screws and micromotion of the baseplate (initial implant fixation) were characterized. Lateralization significantly increases micromotion (p=0.015) and adduction ROM (p=0.001). Using two, versus four, baseplate fixation screws significantly increases micromotion (p=0.008). The effect of lateralization and the number of screws on adduction ROM and baseplate fixation is variable on a shoulder-specific basis. Trade-offs exist between functional outcomes, namely adduction ROM, and initial implant fixation and the negative effect of lateralization on implant fixation is amplified when only two fixation screws are used. The possibility of lateralizing the COR in order to improve functional outcomes of the procedure should be considered on a patient-specific basis accounting for factors such as availability and quality of bone stock. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Tibial Fixation of Anterior Cruciate Ligament Allograft Tendons. Comparison of 1-, 2-, and 4-Stranded Constructs

    DTIC Science & Technology

    2009-01-01

    cruciate ligament reconstruction. Arthroscopy . 1998;14:278-284. 2. Anderson AF, Synder RB, Federspiel CF, Lipscomb AB. Instrumented evaluation of... Arthroscopy . 2003;19(10):14-29. 4. Brand JC Jr, Pienkowski D, Steenlage E, Hamilton D, Johnson DL, Caborn DN. Interference screw fixation strength of a...screws. Arthroscopy . 2003;19:991-996. 8. Chang HC, Nyland J, Nawab A, Burden R, Caborn DN. Biomechanical comparison of the bioabsorbable RetroScrew

  10. Current Concepts in the Mandibular Condyle Fracture Management Part I: Overview of Condylar Fracture

    PubMed Central

    Yang, Jung-Dug; Chung, Ho-Yun; Cho, Byung-Chae

    2012-01-01

    The incidence of condylar fractures is high, but the management of fractures of the mandibular condyle continues to be controversial. Historically, maxillomandibular fixation, external fixation, and surgical splints with internal fixation systems were the techniques commonly used in the treatment of the fractured mandible. Condylar fractures can be extracapsular or intracapsular, undisplaced, deviated, displaced, or dislocated. Treatment depends on the age of the patient, the co-existence of other mandibular or maxillary fractures, whether the condylar fracture is unilateral or bilateral, the level and displacement of the fracture, the state of dentition and dental occlusion, and the surgeonnds on the age of the patient, the co-existence of othefrom which it is difficult to recover aesthetically and functionally;an appropriate treatment is required to reconstruct the shape and achieve the function ofthe uninjured status. To do this, accurate diagnosis, appropriate reduction and rigid fixation, and complication prevention are required. In particular, as mandibular condyle fracture may cause long-term complications such as malocclusion, particularly open bite, reduced posterior facial height, and facial asymmetry in addition to chronic pain and mobility limitation, great caution should be taken. Accordingly, the authors review a general overview of condyle fracture. PMID:22872830

  11. Cerclage wire and lag screw fixation of the lateral malleolus in supination and external rotation fractures of the ankle.

    PubMed

    Bajwa, Amarjit S; Gantz, D E

    2005-01-01

    Wound dehiscence and exposed lateral hardware can occur after open reduction internal fixation of lateral malleolus. The bulk of a lateral plate and the minimum soft tissue over the lateral malleolus may contribute to this situation. The objective of this study was to evaluate a series of patients with lateral malleolar fractures treated with operative reduction using minimal hardware. We wanted to observe whether there was any loss of reduction and whether there were any incidences of soft tissue disruption. Fifty-two patients with long spiral fracture of the lateral malleolus in a supination-external rotation injury were treated with two or three 3.5-mm lag screws inserted 1 cm apart and 1 or 2 circlage wires. Less rigid fixation was supplemented with a below-the-knee plaster cast. All patients were followed up until clinical and radiological evidence of fracture healing at 6, 10, and 14 weeks postoperatively. By 10 weeks, all patients were full weight bearing, although most patients still limped. At 14 weeks' follow-up, there were no infections or wound dehiscences. All patients were able to return to their activities of daily living. All the fractures had united without loss of original position. Two fractures of the posterior bone spikes seen during surgery united uneventfully. Long spiral fractures of the lateral malleolus of the ankle can be treated successfully with 2 or 3 lag screws and circlage wires without compromising the outcome of the fracture healing.

  12. Mechanical induction of critically delayed bone healing in sheep: radiological and biomechanical results.

    PubMed

    Schell, Hanna; Thompson, Mark S; Bail, Hermann J; Hoffmann, Jan-Erik; Schill, Alexander; Duda, Georg N; Lienau, Jasmin

    2008-10-20

    This study aimed to mechanically produce a standardized ovine model for a critically delayed bone union. A tibial osteotomy was stabilized with either a rigid (group I) or mechanically critical (group II) external fixator in sheep. Interfragmentary movements and ground reaction forces were monitored throughout the healing period of 9 weeks. After sacrifice at 6 weeks, 9 weeks and 6 months, radiographs were taken and the tibiae were examined mechanically. Interfragmentary movements were considerably larger in group II throughout the healing period. Unlike group I, the operated limb in group II did not return to full weight bearing during the treatment period. Radiographic and mechanical observations showed significantly inferior bone healing in group II at 6 and 9 weeks compared to group I. After 6 months, five sheep treated with the critical fixator showed radiological bridging of the osteotomy, but the biomechanical strength of the repair was still inferior to group I at 9 weeks. The remaining three animals had even developed a hypertrophic non-union. In this study, mechanical instability was employed to induce a critically delayed healing model in sheep. In some cases, this approach even led to the development of a hypertrophic non-union. The mechanical induction of critical bone healing using an external fixation device is a reasonable attempt to investigate the patho-physiological healing cascade without suffering from any biological intervention. Therefore, the presented ovine model provides the basis for a comparative evaluation of mechanisms controlling delayed and standard bone healing.

  13. Evaluation of bone healing in femurs lengthened via the gradual distraction method.

    PubMed

    Jochymek, Jiri; Gal, Petr

    2007-06-01

    Treatment of leg length inequality via lengthening of the shorter extremity is an infrequent orthopedic procedure due to the requirement of special distraction devices and possible serious complications. Essential qualitative changes in operative technique development are associated with the name of G. A. Ilizarov, who paved the way for the autoregenerate gradual distraction method in the 1950s. In the years 1990 through 2006 a total of 57 patients underwent femur lengthening via gradual distraction using various types of external fixators at the Department of Pediatric Surgery, Orthopedics, and Traumatology, Faculty Hospital in Brno. The quality of bone healing was monitored and a number of parameters followed and statistically evaluated using regularly scheduled X-ray examinations. In 11 cases we had to remove the external fixator following the distraction phase, perform an osteosynthesis via a splint and fill the distraction gap via spongioplasty. The bone healing was satisfactory in the remaining 46 patients and the lengthened bone required no other fixation method. The analysis showed statistically significant deceleration in bone healing following distraction in female patients over 12 years of age, and in boys over 14 years of age. Lack of periosteal callus five weeks after surgery always signified serious problems in further healing. Severe complications were recorded in 11 cases during the distraction phase, and in 9 cases after the removal of the distraction apparatus. The aim of this report was to present the results of our study of distraction gap bone healing using the gradual lengthening approach.

  14. [Analysis of tension-distraction state in the shin bones fractures in conditions of external fixation with application of apparatuses with different spatially oriented supports].

    PubMed

    Hutsuliak, V I

    2014-09-01

    In Autodesk Inventor 11 program, using method of end-capping elements, a three- dimensional computeric modelling of biomechanical systems of two models was conducted: I - "tibia - Ilizarov's apparatus with concentric location of supports"; II - "tibia - Ilizarov's apparatus with excentric location of supports". The loading, which was applied towards distal fragment in 6 standard degrees of freedom, was modelled for studying of the fixation rigidity of tibial fragments in these systems. Determination of the loading value in various directions, in which the fragment have had shifted by 1 mm, have constituted the main task of the investigation. In a model II a rigidity of the fragments fixation, in comparison with such in a model I, is bigger by 631.43% - while applying a compression loading, by 8.35 - 31.75% - the transversal one and by 19.72% - the rotation loading. While choosing the method of transosteal osteosynthesis of the shin bones the advantage, have the apparatuses with excentric location of supports, what secures the enhanced rigidity of the fragments fixation in comparison with such in apparatuses with concentric location of supports. Although, even in excentric location of supports in the apparatus the fixation rigidity is insufficient for early full loading of the traumatized extremity while walking. It is necessary to elaborate such apparatus, the form of which may be adopted toanatomic configuration of segment.

  15. Research on the Perforating Algorithm Based on STL Files

    NASA Astrophysics Data System (ADS)

    Yuchuan, Han; Xianfeng, Zhu; Yunrui, Bai; Zhiwen, Wu

    2018-04-01

    In the process of making medical personalized external fixation brace, the 3D data file should be perforated to increase the air permeability and reduce the weight. In this paper, a perforating algorithm for 3D STL file is proposed, which can perforate holes, hollow characters and engrave decorative patterns on STL files. The perforating process is composed of three steps. Firstly, make the imaginary space surface intersect with the STL model, and reconstruct triangles at the intersection. Secondly, delete the triangular facets inside the space surface and make a hole on the STL model. Thirdly, triangulate the inner surface of the hole, and thus realize the perforating. Choose the simple space equations such as cylindrical and rectangular prism equations as perforating equations can perforate round holes and rectangular holes. Through the combination of different holes, lettering, perforating decorative patterns and other perforated results can be accomplished. At last, an external fixation brace and an individual pen container were perforated holes using the algorithm, and the expected results were reached, which proved the algorithm is feasible.

  16. Contributing risk factors for orthopedic device related infections in sina hospital, tehran, iran.

    PubMed

    Hadadi, A; Zehtab, M J; Babagolzadeh, H; Ashraf, H

    2011-02-01

    In spite of decreasing incidence of orthopedic device-related infections to 1%, nowadays, device-related infection still remains a diagnostic, therapeutic and cost-related problem. The objective of this study is to evaluate the contributing risk factors for orthopedic device-related infections in Sina Hospital, Tehran, Iran. Three hundred and thirty patients who underwent orthopedic device implantation from 2002-2006 were enrolled; among them, 110 patients were complicated with infection. Descriptive and logistic regression analyses were performed to determine the risk factors for device related infections. Patients with infection were older compared to those without infection. The Staphylococcus aureus was the commonest organism. A correlation was observed between wound infection and external fixation, an underlying health condition, and addiction which were independent risk factors for a device related infection. Orthopedic device-related infection puts a great financial burden on patients and hospital resources and could lead to morbidity and mortality in patients. So, appropriate pre and postoperative wound care for dirty wounds, especially when external fixators are used, and in patients with poor conditions or addiction should be done with more caution.

  17. Novel Antibacterial Coating on Orthopedic Wires To Eliminate Pin Tract Infections

    PubMed Central

    Gil, Dmitry; Shuvaev, Sergey; Frank-Kamenetskii, Anastasia; Reukov, Vladimir; Gross, Christopher

    2017-01-01

    ABSTRACT Novel approaches to the prevention of microbial infections after the insertion of orthopedic external fixators are in great demand because of the extremely high incidence rates of such infections, which can reach up to 100% with longer implant residence times. Monolaurin is an antimicrobial agent with a known safety record that is broadly used in the food and cosmetic industries; however, its use in antimicrobial coatings of medical devices has not been studied in much detail. Here, we report the use of monolaurin as an antibacterial coating on external fixators for the first time. Monolaurin-coated Kirschner wires (K-wires) showed excellent antibacterial properties against three different bacterial strains, i.e., methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant Staphylococcus aureus (MRSA), and Staphylococcus epidermidis. Approximately 6.0-log reductions of both planktonic and adherent bacteria were achieved using monolaurin-coated K-wires, but monolaurin-coated K-wires did not show any observable cytotoxicity with mouse osteoblast cell cultures. Overall, monolaurin-coated K-wires could be promising as potent antimicrobial materials for orthopedic surgery. PMID:28483964

  18. Pectoralis Major Repair With Unicortical Button Fixation And Suture Tape.

    PubMed

    Sanchez, Anthony; Ferrari, Marcio B; Frangiamore, Salvatore J; Sanchez, George; Kruckeberg, Bradley M; Provencher, Matthew T

    2017-06-01

    Although injuries of the pectoralis major muscle are generally uncommon, ruptures of the pectoralis major are occasionally seen in younger, more active patients who participate in weightlifting activities. These injuries usually occur during maximal contraction of the muscle, while in extension and external rotation. In the case of a rupture, operative treatment is advocated especially in young, active patients regardless of the chronicity of the injury. Various surgical techniques for reattachment of the avulsed tendon have been described, but bone tunnel and suture anchor repair techniques are most widely used. In this Technical Note, we present our preferred technique for acute pectoralis major rupture repair involving use of cortical buttons for tendon stump-to-bone fixation.

  19. The use of intramedullary nails in tibiotalocalcaneal arthrodesis.

    PubMed

    Thomas, Ruth L; Sathe, Vinayak; Habib, Syed I

    2012-01-01

    Tibiotalocalcaneal arthrodesis is a salvage procedure undertaken for hindfoot problems that affect both the ankle and subtalar joints (eg, two-joint arthritis, severe acute trauma, osteonecrosis of the talus, severe malalignment deformities, significant hindfoot bone loss). Methods of achieving fusion include Steinmann pins, screws, plates, external fixators, and retrograde intramedullary nailing. Retrograde intramedullary nailing provides a load-sharing fixation device with superior biomechanical properties and is an excellent choice for use in tibiotalocalcaneal arthrodesis. This technique can be performed through relatively small incisions. In addition, recent design modifications include the availability of dynamization and the choice of curved or straight nails. Contraindications to the technique include the presence of infection, severe vascular disease, and severe malalignment of the tibia.

  20. Clinical application of locked plating system in children. An orthopaedic view

    PubMed Central

    Zafra-Jimenez, Jose Alberto; Rodriguez Martin, Juan

    2010-01-01

    In recent years, the locked plating system has gained favour in the treatment of certain fractures in adults; however, there is not much information regarding its use in children. We think there could be some advantages and applications such as: an alternative to external fixation, the bridge plating technique, unicortical screws, removal of hardware, metadiaphyseal fractures, periarticular fractures, poor quality bone, and allograft fixation. However, there are some disadvantages to keep in mind and the final decision for using it should be based on the osteosynthesis method principle the surgeon would like to apply. In this review article we discuss the up-to-date possible clinical applications and issues of this system. PMID:20162415

  1. Concomitant Posterior Hip Dislocation, Ipsilateral Intertrochanteric- and Proximal Tibial- Fractures with Popliteal Artery Injury: A Challenging Trauma Mélange.

    PubMed

    Chotai, Pranit N; Ebraheim, Nabil A; Hart, Ryan; Wassef, Andrew

    2015-11-05

    Constellation of ipsilateral posterior hip dislocation, intertrochanteric- and proximal tibial fracture with popliteal artery injury is rare. Management of this presentation is challenging. A motor vehicle accident victim presented with these injuries, but without any initial signs of vascular compromise. Popliteal artery injury was diagnosed intra-operatively and repaired. This was followed by external fixation of tibial fracture, open reduction of dislocated hip and internal fixation of intertrochanteric fracture. Patient regained bilateral complete weight bearing and returned to pre-accident activity level. Apt surgical management including early repair of vascular injury in such a trauma mélange allows for a positive postoperative outcome.

  2. Lengthening of fourth brachymetatarsia by three different surgical techniques.

    PubMed

    Lee, W-C; Yoo, J H; Moon, J-S

    2009-11-01

    We carried out a retrospective study to assess the clinical results of lengthening the fourth metatarsal in brachymetatarsia in 153 feet of 106 patients (100 female, six males) using three different surgical techniques. In one group lengthening was performed by one-stage intercalary bone grafting secured by an intramedullary Kirschner-wire (45 feet, 35 patients). In the second group lengthening was obtained gradually using a mini-external fixator after performing an osteotomy with a saw (59 feet, 39 patients) and in the third group lengthening was achieved in a gradual manner using a mini-external fixator after undertaking an osteotomy using osteotome through pre-drilled holes (49 feet, 32 patients). The mean age of the patients was 26.3 years (13 to 48). Pre-operatively, the fourth ray of the bone-graft group was longer than that of other two groups (p < 0.000). The clinical outcome was compared in the three groups. The mean follow-up was 22 months (7 to 55). At final follow-up, the mean lengthening in the bone-graft group was 13.9 mm (3.5 to 23.0, 27.1%) which was less than that obtained in the saw group with a mean of 17.8 mm (7.0 to 33.0, 29.9%) and in the pre-drilled osteotome group with a mean of 16.8 mm (6.5 to 28.0, 29.4%, p = 0.001). However, the mean time required for retention of the fixation in the bone-graft group was the shortest of the three groups. Patients were dissatisfied with the result for five feet (11.1%) in the bone-graft group, eight (13.6%) in the saw group and none in the pre-drilled osteotomy group (p < 0.000). The saw group included eight feet with failure of bone formation after surgery. Additional operations were performed in 20 feet because of stiffness (n = 7, all groups), failure of bone formation (n = 4, saw group), skin maceration (n = 4, bone-graft group), malunion (n = 4, bone-graft and saw groups) and breakage of the external fixator (n = 1, saw group). We conclude that the gradual lengthening by distraction osteogenesis after osteotomy using an osteotome produces the most reliable results for the treatment of fourth brachymetatarsia.

  3. Minimally invasive fixation of type B and C interprosthetic femoral fractures.

    PubMed

    Ehlinger, M; Czekaj, J; Adam, P; Brinkert, D; Ducrot, G; Bonnomet, F

    2013-09-01

    Interprosthetic femoral fractures are rare and raise unresolved treatment issues such as the length of the fixation material that best prevents secondary fractures. Awareness of the advantages of locked-plate fixation via a minimally invasive approach remains limited, despite the potential of this method for improving success rates. Femur-spanning (from the trochanters to the condyles) locked-plate fixation via a minimally invasive approach provides high healing rates with no secondary fractures. From January 2004 to May 2011, all eight patients seen for interprosthetic fractures were treated with minimally invasive locked-plate fixation. Mean time since hip arthroplasty was 47.5 months and mean time since knee arthroplasty was 72.6 months. There were 12 standard primary prostheses and four revision prostheses; 11 prostheses were cemented and a single prosthesis showed femoral loosening. Classification about the hip prostheses was Vancouver B in one patient and Vancouver C in seven patients; about the knee prosthesis, the fracture was SoFCOT B in three patients and SOFCOT C in five patients, and a single fracture was SoFCOT D. Minimally invasive locking-plate fixation was performed in all eight patients, with installation on a traction table in seven patients. Healing was obtained in all eight patients, after a mean of 14 weeks (range, 12-16 weeks). One patient had malalignment with more than 5° of varus. There were no general or infectious complications. One patient died, 32 months after surgery. The mean Parker-Palmer mobility score decreased from 6.2 pre-operatively to 2.5 at last follow-up. Early construct failure after 3 weeks in one patient required surgical revision. There was no change in implant fixation at last follow-up. No secondary fractures were recorded. In patients with type B or C interprosthetic fractures, femur-spanning fixation not only avoids complications related to altered bone stock and presence of prosthetic material, but also decreases the risk of secondary fractures by eliminating stress riser zones. The minimally invasive option enhances healing by preserving the fracture haematoma. Thus, healing was obtained consistently in our patients, with no secondary fractures, although the construct failed in one patient. Level IV. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  4. Biomechanical analysis of anterior versus posterior instrumentation following a thoracolumbar corpectomy: Laboratory investigation.

    PubMed

    Viljoen, Stephanus V; DeVries Watson, Nicole A; Grosland, Nicole M; Torner, James; Dalm, Brian; Hitchon, Patrick W

    2014-10-01

    The objective of this study was to evaluate the biomechanical properties of lateral instrumentation compared with short- and long-segment pedicle screw constructs following an L-1 corpectomy and reconstruction with an expandable cage. Eight human cadaveric T10-L4 spines underwent an L-1 corpectomy followed by placement of an expandable cage. The spines then underwent placement of lateral instrumentation consisting of 4 monoaxial screws and 2 rods with 2 cross-connectors, short-segment pedicle screw fixation involving 1 level above and below the corpectomy, and long-segment pedicle screw fixation (2 levels above and below). The order of instrumentation was randomized in the 8 specimens. Testing was conducted for each fixation technique. The spines were tested with a pure moment of 6 Nm in all 6 degrees of freedom (flexion, extension, right and left lateral bending, and right and left axial rotation). In flexion, extension, and left/right lateral bending, posterior long-segment instrumentation had significantly less motion compared with the intact state. Additionally, posterior long-segment instrumentation was significantly more rigid than short-segment and lateral instrumentation in flexion, extension, and left/right lateral bending. In axial rotation, the posterior long-segment construct as well as lateral instrumentation were not significantly more rigid than the intact state. The posterior long-segment construct was the most rigid in all 6 degrees of freedom. In the setting of highly unstable fractures requiring anterior reconstruction, and involving all 3 columns, long-segment posterior pedicle screw constructs are the most rigid.

  5. [Clinical experience with various techniques integrated treat the wounded with gunshot fractures of limbs].

    PubMed

    Kozlov, V K; Akhmedov, B G; Chililov, A M

    To increase an efficiency of complex treatment of patients with diaphyseal gunshot fractures of long bones by introduction of modern minimally invasive surgical techniques of internal osteosynthesis into clinical practice of civil health care and to improve the outcomes in victims. Prospective comparative clinical trial included 104 victims from the Republic of Yemen with gunshot wounds of limbs of various severity for the period 2009-2011. There were diaphyseal fractures of long bones of limbs associated with soft tissue injuries. Men were predominant (80.7%). Age ranged from 15 to 80 years (mean 38,5 ± 5,7 years). Various surgical techniques of simultaneous and staged treatment were used for gunshot fractures of long bones of limbs. Additional immune therapy was prescribed to prevent infectious complications in the most severe cases. Victims were comprehensively treated according to different staged treatment: conventional surgical treatment with external fixation devices or early primary minimally invasive functionally stable osteosynthesis with LCP/BIOS plates were applied for low-energy fractures; in case of high-energy fractures the first stage included external fixation devices deployment followed by their subsequent replacement during delayed minimally invasive osteosynthesis. The essence of improvement is pursuit to simultaneous minimally invasive surgery by using of current plates for osteosynthesis and preventive immunotherapy of immune dysfunction to eliminate infectious complications. As a result, we obtained 2-fold decrease of surgical invasiveness (r≤0,01) and hospital-stay (r≤0,01). Repeated osteosynthesis was not made. Also 4-fold and 40-fold reduction of infectious and noninfectious complications was observed. This management was accompanied by reduced rehabilitation tine and significantly improved quality of life. Improved technique and algorithm of complex treatment of diaphyseal gunshot fractures of long bones of limbs were described. Early minimally invasive functionally stable osteosynthesis with modern implants and non-specific immune prevention of infectious complications are more effective and economically justified compared with conventional treatment including external fixation devices without immunoactive therapy.

  6. [Distraction Osteogenesis is an Effective Method to Lengthen Digits in Congenital Malformations].

    PubMed

    Mann, M; Hülsemann, W; Winkler, F; Habenicht, R

    2016-02-01

    The aim of this study was to investigate the feasible amount of lengthening by distraction osteogenesis in congenital hand deficiencies. A total of 60 patients (1.6-17.8 years) underwent lengthening of 71 bones between 1994 and 2014. Bone lengthening was performed on 46 metacarpals and 25 phalanges. Mostly the first (n=30) and the fifth (n=21) rays were lengthened. Bone lengthening was performed to treat primarily symbrachydactyly (b=32) and amniotic band syndrome (n=10). To analyze the amount of lengthening preoperative radiographs and radiographs taken while removing the external fixator were compared. The charts were reviewed regarding age at surgery, duration of lengthening, duration of bony consolidation, complication, etc. The average of metacarpal distraction was 18.4 mm=73% lengthening with respect to the preoperative length; the average of phalange distraction was 14.0 mm=77% of the preoperative length. In both, metacarpals and phalanges, a lengthening of > 100% of the preoperative bone length was possible. In target length was reached in 89% of the procedures. The average time for consolidation was 6.1 (1-20) days/mm lengthening. The external fixator was in use on average for 140 (50-346) days. After removing of the external fixator an axial K-wire was used to stabilize the callus in 9 procedure, and an iliac bone craft plus axial K-wire in 11 procedures. The rate of complications was 30% (early consolidation, deviation, joint dislocation, pin infection, tendon dislocation). All complications could be treated without with acceptable results. Metacarpal and phalangeal distraction lengthening is an effective but demanding technique for ray reconstruction in congenital malformations of the hand. It is possible to lengthen a bone by more than 100%. Complications are common, but in most cases easy to handle. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Posterior locked lateral compression injury of the pelvis in geriatric patients: an infrequent and specific variant of the fragility fracture of pelvis.

    PubMed

    Lee, Se-Won; Kim, Weon-Yoo; Koh, Sung-Jun; Kim, Young-Yul

    2017-09-01

    Posterior locked lateral compression injury (PLLCI) of the pelvic ring is an infrequent variant of lateral compression injury, a condition described in only eight reported cases since 2000. Lateral compression injury usually results from high-energy trauma and is characterized by locking between the medially translated fractured ilium and the anterior border of the sacrum, regardless of whether the fractured ilium involves the sacroiliac joint. However, in our experience, lateral compression injury can also result from low-energy trauma as a manifestation of pelvic fragility fracture. The aim of the present study was to describe this rare form of PLLCI in a case series of geriatric patients. A retrospective analysis of consecutive patients with pelvic ring injuries who were admitted to our hospital from January 2008 to April 2015 identified seven geriatric patients (1 male and 6 females; median age 81 years) with a form of PLLCI. All injuries were due to falls from a standing position onto the ground. All seven cases demonstrated characteristics of a locking fractured ilium over the anterior border of the sacrum on axial computed tomography images, but were not detected on plain radiographs. All underwent follow-up at 1 year or later with improved mean visual analogue scale scores (range 0-3). Regarding Koval walking ability scores, patients who underwent pelvic brim plating with anterior external fixation were more likely to regain their pre-injury walking ability than patients who only underwent anterior external fixation or conservative treatment. Geriatric patients can experience PLCCIs of the pelvis due to low-energy trauma. These fractures have different characteristics from those associated with severe injuries due to high-energy trauma, and they comprise an infrequent form of Rommens fragility fracture of the pelvis (type IIIa). In these cases, appropriate surgical management that includes sacroiliac plating combined with anterior external fixation can yield good outcomes.

  8. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion.

    PubMed

    Sod, Gary A; Riggs, Laura M; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S

    2010-01-01

    To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=15 pairs). For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation. The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.

  9. Systems analysis of the CO2 concentrating mechanism in cyanobacteria

    PubMed Central

    Mangan, Niall M; Brenner, Michael P

    2014-01-01

    Cyanobacteria are photosynthetic bacteria with a unique CO2 concentrating mechanism (CCM), enhancing carbon fixation. Understanding the CCM requires a systems level perspective of how molecular components work together to enhance CO2 fixation. We present a mathematical model of the cyanobacterial CCM, giving the parameter regime (expression levels, catalytic rates, permeability of carboxysome shell) for efficient carbon fixation. Efficiency requires saturating the RuBisCO reaction, staying below saturation for carbonic anhydrase, and avoiding wasteful oxygenation reactions. We find selectivity at the carboxysome shell is not necessary; there is an optimal non-specific carboxysome shell permeability. We compare the efficacy of facilitated CO2 uptake, CO2 scavenging, and HCO3− transport with varying external pH. At the optimal carboxysome permeability, contributions from CO2 scavenging at the cell membrane are small. We examine the cumulative benefits of CCM spatial organization strategies: enzyme co-localization and compartmentalization. DOI: http://dx.doi.org/10.7554/eLife.02043.001 PMID:24842993

  10. Evaluation and treatment recommendations for acute injuries to the ankle syndesmosis without associated fracture.

    PubMed

    Miller, Timothy L; Skalak, Timothy

    2014-02-01

    Ankle ligamentous injuries are commonly seen in athletes in a variety of sports. Surveys of physicians and trainers of professional sports teams have identified syndesmotic injuries as among the most difficult to treat. In particular, injuries of the ankle syndesmosis have been strongly linked with a prolonged recovery and increased time to return to play. Due to sudden external rotation with the tibiotalar joint in dorsiflexion, these structures are commonly injured in association with fractures of the distal fibula. Surgery is indicated in cases with associated fractures and ligamentous instability, but optimal treatment for syndesmosis injuries without an associated fracture is less clear. A thorough history and physical examination, as well as appropriate imaging, are necessary to effectively diagnose and classify the injury. For stable injuries, short-term immobilization and functional rehabilitation is recommended. Unstable Grade 2 and 3 injuries require surgical fixation. Debate currently exists over rigid screw fixation versus suture button techniques as the ideal fixation method.

  11. Complications of ankle fracture in patients with diabetes.

    PubMed

    Chaudhary, Saad B; Liporace, Frank A; Gandhi, Ankur; Donley, Brian G; Pinzur, Michael S; Lin, Sheldon S

    2008-03-01

    Ankle fractures in patients with diabetes mellitus have long been recognized as a challenge to practicing clinicians. Complications of impaired wound healing, infection, malunion, delayed union, nonunion, and Charcot arthropathy are prevalent in this patient population. Controversy exists as to whether diabetic ankle fractures are best treated noninvasively or by open reduction and internal fixation. Patients with diabetes are at significant risk for soft-tissue complications. In addition, diabetic ankle fractures heal, but significant delays in bone healing exist. Also, Charcot ankle arthropathy occurs more commonly in patients who were initially undiagnosed and had a delay in immobilization and in patients treated nonsurgically for displaced ankle fractures. Several techniques have been described to minimize complications associated with diabetic ankle fractures (eg, rigid external fixation, use of Kirschner wires or Steinmann pins to increase rigidity). Regardless of the specifics of treatment, adherence to the basic principles of preoperative planning, meticulous soft-tissue management, and attention to stable, rigid fixation with prolonged, protected immobilization are paramount in minimizing problems and yielding good functional outcomes.

  12. The effect of beat frequency on eye movements during free viewing.

    PubMed

    Maróti, Emese; Knakker, Balázs; Vidnyánszky, Zoltán; Weiss, Béla

    2017-02-01

    External periodic stimuli entrain brain oscillations and affect perception and attention. It has been shown that background music can change oculomotor behavior and facilitate detection of visual objects occurring on the musical beat. However, whether musical beats in different tempi modulate information sampling differently during natural viewing remains to be explored. Here we addressed this question by investigating how listening to naturalistic drum grooves in two different tempi affects eye movements of participants viewing natural scenes on a computer screen. We found that the beat frequency of the drum grooves modulated the rate of eye movements: fixation durations were increased at the lower beat frequency (1.7Hz) as compared to the higher beat frequency (2.4Hz) and no music conditions. Correspondingly, estimated visual sampling frequency decreased as fixation durations increased with lower beat frequency. These results imply that slow musical beats can retard sampling of visual information during natural viewing by increasing fixation durations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. An External Wire Frame Fixation Method of Skin Grafting for Burn Reconstruction.

    PubMed

    Yoshino, Yukiko; Ueda, Hyakuzoh; Ono, Simpei; Ogawa, Rei

    2017-06-28

    The skin graft is a prevalent reconstructive method for burn injuries. We have been applying external wire frame fixation methods in combination with skin grafts since 1986 and have experienced better outcomes in percentage of successful graft take. The overall purpose of this method was to further secure skin graft adherence to wound beds in hard to stabilize areas. There are also location-specific benefits to this technique such as eliminating the need of tarsorrhaphy in periorbital area, allowing immediate food intake after surgery in perioral area, and performing less invasive fixing methods in digits, and so on. The purpose of this study was to clarify its benefits and applicable locations. We reviewed 22 postburn patients with skin graft reconstructions using the external wire frame method at our institution from December 2012 through September 2016. Details of the surgical technique and individual reports are also discussed. Of the 22 cases, 15 (68%) were split-thickness skin grafts and 7 (32%) were full-thickness skin grafts. Five cases (23%) involved periorbital reconstruction, 5 (23%) involved perioral reconstruction, 2 (9%) involved lower limb reconstruction, and 10 (45%) involved digital reconstruction. Complete (100%) survival of the skin graft was attained in all cases. No signs of complication were observed. With 30 years of experiences all combined, we have summarized fail-proof recommendations to a successful graft survival with an emphasis on the locations of its application.

  14. Scapulothoracic dissociation with acromioclavicular separation: a case report of a novel fixation method.

    PubMed

    Merk, Bradley R; Minihane, Keith P; Shah, Nirav A

    2008-09-01

    We present a case of 39-year-old female with a scapulothoracic dissociation and acromioclavicular (AC) separation and who had fixation of the AC joint with a locking plate, coracoclavicular screw, and transarticular AC screw. The coracoclavicular and AC relationships were maintained during postoperative rehabilitation and after hardware removal. Use of a locking plate can lead to good functional outcome without the complications associated with the use of pin and wire constructs or without violating the subacromial space.

  15. Motion Predicts Clinical Callus Formation

    PubMed Central

    Elkins, Jacob; Marsh, J. Lawrence; Lujan, Trevor; Peindl, Richard; Kellam, James; Anderson, Donald D.; Lack, William

    2016-01-01

    Background: Mechanotransduction is theorized to influence fracture-healing, but optimal fracture-site motion is poorly defined. We hypothesized that three-dimensional (3-D) fracture-site motion as estimated by finite element (FE) analysis would influence callus formation for a clinical series of supracondylar femoral fractures treated with locking-plate fixation. Methods: Construct-specific FE modeling simulated 3-D fracture-site motion for sixty-six supracondylar femoral fractures (OTA/AO classification of 33A or 33C) treated at a single institution. Construct stiffness and directional motion through the fracture were investigated to assess the validity of construct stiffness as a surrogate measure of 3-D motion at the fracture site. Callus formation was assessed radiographically for all patients at six, twelve, and twenty-four weeks postoperatively. Univariate and multivariate linear regression analyses examined the effects of longitudinal motion, shear (transverse motion), open fracture, smoking, and diabetes on callus formation. Construct types were compared to determine whether their 3-D motion profile was associated with callus formation. Results: Shear disproportionately increased relative to longitudinal motion with increasing bridge span, which was not predicted by our assessment of construct stiffness alone. Callus formation was not associated with open fracture, smoking, or diabetes at six, twelve, or twenty-four weeks. However, callus formation was associated with 3-D fracture-site motion at twelve and twenty-four weeks. Longitudinal motion promoted callus formation at twelve and twenty-four weeks (p = 0.017 for both). Shear inhibited callus formation at twelve and twenty-four weeks (p = 0.017 and p = 0.022, respectively). Titanium constructs with a short bridge span demonstrated greater longitudinal motion with less shear than did the other constructs, and this was associated with greater callus formation (p < 0.001). Conclusions: In this study of supracondylar femoral fractures treated with locking-plate fixation, longitudinal motion promoted callus formation, while shear inhibited callus formation. Construct stiffness was found to be a poor surrogate of fracture-site motion. Future implant design and operative fixation strategies should seek to optimize 3-D fracture-site motion rather than rely on surrogate measures such as axial stiffness. PMID:26888675

  16. Low Profile Mesh Plating for Patella Fractures: Video of a Novel Surgical Technique.

    PubMed

    Verbeek, Diederik O; Hickerson, Lindsay E; Warner, Stephen J; Helfet, David L; Lorich, Dean G

    2016-08-01

    Patella fractures can be challenging to treat particularly in the presence of inferior pole comminution. In this video we present a novel surgical technique for the treatment of patella fractures using a small fragment low profile mesh plate. Key points are the surgical exposure with direct visualization of the articular reduction, the preparation of the mesh plate to accommodate patellar anatomy and the augmentation of the construct using Krackow sutures to address inferior pole comminution. Low profile mesh plating allows for multiplanar fixation of patella fractures while avoiding implant and fixation problems related to tension band fixation. Our early experience with this technique is encouraging and it appears that this technique is useful for the treatment of the majority of patella fractures.

  17. An improved method for cable grip fixation of the greater trochanter after trochanteric slide osteotomy.

    PubMed

    Thakur, Nikhil A; Crisco, Joseph J; Moore, Douglas C; Froehlich, John A; Limbird, Richard S; Bliss, James M

    2010-02-01

    This study proposes a novel method for reattachment of the trochanteric slide osteotomy. The strength of this new fixation system was compared to established configurations. Fifteen sawbone femurs were used. Our configuration used cables above and below the lesser trochanter with a third cable around the shaft of the femur while passing the loose ends through the inferior hole of the cable grip. Displacement of the trochanter was measured with increasing load. Force required for catastrophic failure was also measured. The 3-cable construct resulted in significantly less displacement with increasing load and required a larger force to cause failure (1 cm and 2 cm). We theorize that our configuration produces a biomechanically stronger construct than previously used methods. 2010 Elsevier Inc. All rights reserved.

  18. An Improved Method for Cable Grip Fixation of the Greater Trochanter After Trochanteric Slide Osteotomy

    PubMed Central

    Thakur, Nikhil A.; Crisco, Joseph J.; Moore, Douglas C.; Froehlich, John A.; Limbird, Richard S.; Bliss, James M.

    2017-01-01

    This study proposes a novel method for reattachment of the trochanteric slide osteotomy. The strength of this new fixation system was compared to established configurations. Fifteen sawbone femurs were used. Our configuration used cables above and below the lesser trochanter with a third cable around the shaft of the femur while passing the loose ends through the inferior hole of the cable grip. Displacement of the trochanter was measured with increasing load. Force required for catastrophic failure was also measured. The 3-cable construct resulted in significantly less displacement with increasing load and required a larger force to cause failure (1 cm and 2 cm). We theorize that our configuration produces a biomechanically stronger construct than previously used methods. PMID:19062247

  19. Posttraumatic severe infection of the ankle joint - long term results of the treatment with resection arthrodesis in 133 cases

    PubMed Central

    2010-01-01

    Although there is a clear trend toward internal fixation for ankle arthrodesis, there is general consensus that external fixation is required for cases of posttraumatic infection. We retrospectively evaluated the technique and clinical long term results of external fixation in a triangular frame for cases of posttraumatic infection of the ankle. From 1993 to 2006 a consecutive series of 155 patients with an infection of the ankle was included in our study. 133 cases of the advanced "Gächter" stage III and IV were treated with arthrodesis. We treated the patients with a two step treatment plan. After radical debridement and sequestrectomy the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted in the tibia and in the calcaneus and the gap was temporary filled with gentamicin beads as the first step. In the second step we performed an autologous bone graft after a period of four weeks. The case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues. Mean age at the index procedure was 49.7 years (18-82), 104 patients were male (67,1%). Follow up examination after mean 4.5 years included a standardised questionnaire and a clinical examination including the criteria of the AO-FAS-Score and radiographs. 92,7% of the cases lead to a stable arthrodesis. In 5 patients the arthrodesis was found partly-stable. In six patients (4,5%) the infection was not controllable during the treatment process. These patients had to be treated with a below knee amputation. The mean AOFAS score at follow up was 63,7 (53-92). Overall there is a high degree of remaining disability. The complication rate and the reduced patient comfort reserve this method mainly for infection. Joint salvage is possible in the majority of cases with an earlier stage I and II infection. PMID:20452884

  20. Posttraumatic severe infection of the ankle joint - long term results of the treatment with resection arthrodesis in 133 cases.

    PubMed

    Kienast, Benjamin; Kiene, J; Gille, J; Thietje, R; Gerlach, U; Schulz, A P

    2010-02-26

    Although there is a clear trend toward internal fixation for ankle arthrodesis, there is general consensus that external fixation is required for cases of posttraumatic infection. We retrospectively evaluated the technique and clinical long term results of external fixation in a triangular frame for cases of posttraumatic infection of the ankle. From 1993 to 2006 a consecutive series of 155 patients with an infection of the ankle was included in our study. 133 cases of the advanced "Gächter" stage III and IV were treated with arthrodesis. We treated the patients with a two step treatment plan. After radical debridement and sequestrectomy the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted in the tibia and in the calcaneus and the gap was temporary filled with gentamicin beads as the first step. In the second step we performed an autologous bone graft after a period of four weeks. The case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues. Mean age at the index procedure was 49.7 years (18-82), 104 patients were male (67.1%). Follow up examination after mean 4.5 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. 92.7% of the cases lead to a stable arthrodesis. In 5 patients the arthrodesis was found partly-stable. In six patients (4,5%) the infection was not controllable during the treatment process. These patients had to be treated with a below knee amputation. The mean AOFAS score at follow up was 63.7 (53-92). Overall there is a high degree of remaining disability. The complication rate and the reduced patient comfort reserve this method mainly for infection. Joint salvage is possible in the majority of cases with an earlier stage I and II infection.

  1. Influence of bolt tightening torque, wire size, and component reuse on wire fixation in circular external fixation.

    PubMed

    Wosar, Marc A; Marcellin-Little, Denis J; Roe, Simon C

    2002-01-01

    To evaluate the effects of bolt torque, wire size, and component reuse on the ability to maintain wire tension in 3 external skeletal fixation systems. Biomechanical study. Yield strength in tension of 1.0-, 1.2-, 1.5-, and 1.6-mm-diameter wires, and yield strength in torque of Hofmann Small Bone Fixation (SBF) cannulated and slotted bolts and IMEX regular and miniature bolts were determined on a testing machine. The minimum bolt tightening torque needed to prevent wire slippage at clinically recommended wire tensions was determined. Components were tested 10 times, and loads at slippage were recorded. The IMEX system required a mean of 8 Nm of bolt tightening torque to maintain 900 N (1.6-mm wires). The SBF system required a mean of 3 Nm bolt torque to maintain 300 N (1.0-mm wires) and 5 Nm to maintain 600 N (1.2-mm wires). The SBF cannulated bolt required 9 Nm of torque to maintain 900 N (1.5-mm wires). The SBF slotted bolts could only maintain 800 N before yield. The IMEX miniature system required a mean bolt torque of 1.1 Nm to maintain 300 N. The cannulated and slotted bolts from both manufacturers failed to maintain 70% of initial wire tension after 7 and 4 uses, respectively. The IMEX systems and the SBF system using 1.0- and 1.2-mm wires could maintain clinically recommended wire tension safely. Only the IMEX system could maintain clinically recommended wire tension safely using 1.5- or 1.6-mm wires. The SBF system using 1.0- and 1.2-mm wires and the IMEX system using all wire sizes can maintain clinically relevant wire tension. The SBF system using 1.5-mm wires could not. Cannulated and slotted bolts should not be used more than 6 and 3 times, respectively. Nuts should not be reused. Copyright 2002 by The American College of Veterinary Surgeons

  2. The Feasibility of Two Screws Anterior Fixation for Type II Odontoid Fracture Among Arabs.

    PubMed

    Marwan, Yousef; Kombar, Osama Rabie; Al-Saeed, Osama; Aleidan, Aljarrah; Samir, Ahmed; Esmaeel, Ali

    2016-06-01

    Retrospective, cross-sectional study. To evaluate the feasibility of two screws anterior fixation of the odontoid process among Arab adults. Anterior screw fixation is the treatment of choice for type II odontoid fractures. In order to perform the procedure safely, the diameter of the odontoid process should be wide enough to allow for the placement of one or two screws. A retrospective review of 156 computed tomography scans of the cervical spine was done. The included patients were Arabs, adults (at least 18 years old), and had no evidence of upper cervical spine trauma, deformity, infection, tumor, or surgery. The minimum external transverse diameter (METD), minimum internal transverse diameter (MITD), minimum external anteroposterior diameter (MEAD), and minimum internal anteroposterior diameter (MIAD) of the odontoid process were measured. A P value of ≤0.05 was considered as the cutoff level of statistical significance. Our study included 94 (60.3%) males and 62 (39.7%) females. The mean age of the subjects was 37.8 ± 16.9 years (range 18-85). The mean values of the METD, MITD, MEAD, and MIAD were 8.7 ± 1.0 mm, 6.0 ± 1.1 mm, 10.3 ± 1.0 mm, and 7.4 ± 1.1 mm, respectively. Men had larger diameters compared to women. This was statistically significant for METD (P = 0.035) and MEAD (P < 0.001). The METD was <9.0 mm in 95 (60.9%) subjects, while the MITD was <8.0 mm in 153 (98.1%) subjects. These findings were not significantly different between males and females. Two screws anterior fixation of type II odontoid fracture is not feasible among the majority of Arabs. 3.

  3. Arthrodesis of the knee after failed knee replacement.

    PubMed

    Wade, P J; Denham, R A

    1984-05-01

    Arthrodesis of the knee is sometimes needed for failed total knee replacement, but fusion can be difficult to obtain. We describe a method of arthrodesis that uses the simple, inexpensive, Portsmouth external fixator. Bony union was obtained in all six patients treated with this technique. These results are compared with those obtained by other methods of arthrodesis.

  4. A comparison of biomechanical stability and pullout strength of two C1-C2 fixation constructs.

    PubMed

    Savage, Jason W; Limthongkul, Worawat; Park, Hyung-Soon; Zhang, Li-Qun; Karaikovic, Eldin E

    2011-07-01

    Several fusion techniques are used to treat atlantoaxial instability. Recent literature suggests that intralaminar screw (LS) fixation and pedicle screw (PS) fixation offer similar stability and comparable pullout strength. No studies have compared these characteristics after cyclic loading. To compare the stability and pullout strength of intra-LSs and PSs in a C1-C2 instability model after 1,000 cycles of axial loading. In vitro biomechanical study. Stability in axial rotation and screw pullout strength after cyclic loading. Six fresh-frozen human cadaveric cervical spines (C1-C2) were used in this study. C1-C2 instability was mimicked via odontoidotomy at its base and posterior soft-tissue release, including the supraspinous ligaments and facet joint capsules. Specimens were tested to 1,000 cycles after stabilization with two fixation constructs: C1 lateral mass (LM) screws and C2 intra-LSs (C1LM-C2LS) and C1 LM screws and C2 PSs (C1LM-C2PS). Angular motion was recorded for right and left axial rotation using an Optotrak 3020 system (Northern Digital, Waterloo, Ontario, Canada). Tensile loading to failure was then performed collinear to the longitudinal axis of the screw, and the data were recorded as peak pullout strength in newtons. There was no statistically significant difference in stability (measured in degrees of rotation) between the intra-LS and PS constructs at 250, 500, 750, and 1,000 cycles of axial rotation. Furthermore, there was no significant difference in stability at 250 cycles versus 1,000 cycles for the LS (1.30 vs. 1.49, p = .80) or PS (0.84 vs. 0.85, p = .96). Pedicle screws had higher pullout strength when compared with the intra-LSs (757.5 ± 239 vs. 583.4 ± 472 N); however, high standard deviation precluded statistical significance (p = .44). Our data suggest that a C1LM and C2LS construct has similar biomechanical stability when compared with a C1LM and C2PS construct after 1,000 cycles of axial rotation. Furthermore, PSs had higher pullout strength when compared with LSs; however, this result was not statistically significant. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. A Locally Weighted Fixation Density-Based Metric for Assessing the Quality of Visual Saliency Predictions

    NASA Astrophysics Data System (ADS)

    Gide, Milind S.; Karam, Lina J.

    2016-08-01

    With the increased focus on visual attention (VA) in the last decade, a large number of computational visual saliency methods have been developed over the past few years. These models are traditionally evaluated by using performance evaluation metrics that quantify the match between predicted saliency and fixation data obtained from eye-tracking experiments on human observers. Though a considerable number of such metrics have been proposed in the literature, there are notable problems in them. In this work, we discuss shortcomings in existing metrics through illustrative examples and propose a new metric that uses local weights based on fixation density which overcomes these flaws. To compare the performance of our proposed metric at assessing the quality of saliency prediction with other existing metrics, we construct a ground-truth subjective database in which saliency maps obtained from 17 different VA models are evaluated by 16 human observers on a 5-point categorical scale in terms of their visual resemblance with corresponding ground-truth fixation density maps obtained from eye-tracking data. The metrics are evaluated by correlating metric scores with the human subjective ratings. The correlation results show that the proposed evaluation metric outperforms all other popular existing metrics. Additionally, the constructed database and corresponding subjective ratings provide an insight into which of the existing metrics and future metrics are better at estimating the quality of saliency prediction and can be used as a benchmark.

  6. Recovering faces from memory: the distracting influence of external facial features.

    PubMed

    Frowd, Charlie D; Skelton, Faye; Atherton, Chris; Pitchford, Melanie; Hepton, Gemma; Holden, Laura; McIntyre, Alex H; Hancock, Peter J B

    2012-06-01

    Recognition memory for unfamiliar faces is facilitated when contextual cues (e.g., head pose, background environment, hair and clothing) are consistent between study and test. By contrast, inconsistencies in external features, especially hair, promote errors in unfamiliar face-matching tasks. For the construction of facial composites, as carried out by witnesses and victims of crime, the role of external features (hair, ears, and neck) is less clear, although research does suggest their involvement. Here, over three experiments, we investigate the impact of external features for recovering facial memories using a modern, recognition-based composite system, EvoFIT. Participant-constructors inspected an unfamiliar target face and, one day later, repeatedly selected items from arrays of whole faces, with "breeding," to "evolve" a composite with EvoFIT; further participants (evaluators) named the resulting composites. In Experiment 1, the important internal-features (eyes, brows, nose, and mouth) were constructed more identifiably when the visual presence of external features was decreased by Gaussian blur during construction: higher blur yielded more identifiable internal-features. In Experiment 2, increasing the visible extent of external features (to match the target's) in the presented face-arrays also improved internal-features quality, although less so than when external features were masked throughout construction. Experiment 3 demonstrated that masking external-features promoted substantially more identifiable images than using the previous method of blurring external-features. Overall, the research indicates that external features are a distractive rather than a beneficial cue for face construction; the results also provide a much better method to construct composites, one that should dramatically increase identification of offenders.

  7. Implant material and design alter construct stiffness in distal femur locking plate fixation: a pilot study.

    PubMed

    Schmidt, Ulf; Penzkofer, Rainer; Bachmaier, Samuel; Augat, Peter

    2013-09-01

    Construct stiffness affects healing of bones fixed with locking plates. However, variable construct stiffness reported in the literature may be attributable to differing test configurations and direct comparisons may clarify these differences. We therefore asked whether different distal femur locking plate systems and constructs will lead to different (1) axial and rotational stiffness and (2) fatigue under cyclic loading. We investigated four plate systems for distal femur fixation (AxSOS, LCP, PERI-LOC, POLYAX) of differing designs and materials using bone substitutes in a distal femur fracture model (OTA/AO 33-A3). We created six constructs of each of the four plating systems. Stiffness under static and cyclic loading and fatigue under cyclic loading were measured. Mean construct stiffness under axial loading was highest for AxSOS (100.8 N/mm) followed by PERI-LOC (80.8 N/mm) and LCP (62.6 N/mm). POLYAX construct stiffness testing showed the lowest stiffness (51.7 N/mm) with 50% stiffness of AxSOS construct testing. Mean construct stiffness under torsional loading was similar in the group of AxSOS and PERI-LOC (3.40 Nm/degree versus 3.15 Nm/degree) and in the group of LCP and POLYAX (2.63 Nm/degree versus 2.56 Nm/degree). The fourth load level of > 75,000 cycles was reached by three of six AxSOS, three of six POLYAX, and two of six PERI-LOC constructs. All others including all LCP constructs failed earlier. Implant design and material of new-generation distal femur locking plate systems leads to a wide range of differences in construct stiffness. Assuming construct stiffness affects fracture healing, these data may influence surgical decision-making in choosing an implant system.

  8. Primary ankle arthrodesis for neglected open Weber B ankle fracture dislocation.

    PubMed

    Thomason, Katherine; Ramesh, Ashwanth; McGoldrick, Niall; Cove, Richard; Walsh, James C; Stephens, Michael M

    2014-01-01

    Primary ankle arthrodesis used to treat a neglected open ankle fracture dislocation is a unique decision. A 63-year-old man presented to the emergency department with a 5-day-old open fracture dislocation of his right ankle. After thorough soft tissue debridement, primary arthrodesis of the tibiotalar joint was performed using initial Kirschner wire fixation and an external fixator. Definitive soft tissue coverage was later achieved using a latissimus dorsi free flap. The fusion was consolidated to salvage the limb from amputation. The use of primary arthrodesis to treat a compound ankle fracture dislocation has not been previously described. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Complications encountered with circular ring fixation in persons with diabetes mellitus.

    PubMed

    Wukich, Dane K; Belczyk, Ronald J; Burns, Patrick R; Frykberg, Robert G

    2008-10-01

    The purpose of this study was to identify and report the complications associated with the use of circular ring fixation in diabetic patients, and to compare the frequency of complications in patients without diabetes. We hypothesized that complications with circular ring fixation occurred more frequently in patients with diabetes than patients without diabetes. Institutional Review Board approval was obtained and patient charts were retrospectively reviewed from June 2004 and February 2007. Fifty six consecutive patients undergoing midfoot, hindfoot and/or ankle surgery were treated with circular ring fixation which included 33 diabetic patients in the study group and 23 non-diabetic patients in the control group. Patient demographics, the duration of treatment with the external fixator, and complications were recorded. Males had a greater number of complications compared to females (p = 0.0014). The total number of complications was statistically greater in diabetic patients (study group) versus non-diabetic patients (control group) (p = 0.003). In multivariate logistic regression, diabetes and male sex were the only significant variables associated with wire complications (OR 7.35, 95% CI 1.93-28.04 and OR 0.22, 95% CI 0.05-8584111, respectively). Women are protected from wire complications with a risk reduction of 78% compared to males. Diabetics have a 7-fold risk for any wire complication compared to patients without diabetes. We found no adverse effects of BMI, obesity, age, smoking, neuropathy, or Charcot neuroarthropathy on a satisfactory recovery.

  10. How I do it: feasibility of a new ultrasound probe fixator to facilitate high quality stress echocardiography.

    PubMed

    Salden, O A E; van Everdingen, W M; Spee, R; Doevendans, P A; Cramer, M J

    2018-03-27

    Stress echocardiography (SE) has recently regained momentum as an important diagnostic tool for the assessment of both ischemic and non-ischemic heart disease. Performing SE during physical exercise is challenging due to a suboptimal patient position and vigorous movements of the patient's chest. This hampers a stable ultrasound position and reduces the diagnostic performance of SE. A stable ultrasound probe position would facilitate producing high quality images during continuous measurements. With Probefix (Usono, Eindhoven, The Netherlands), a newly developed tool to fixate the ultrasound probe to the patient's chest, stabilization of the probe during physical exercise is possible. The technique of SE with the Probefix and its' feasibility are evaluated in a small pilot study. Probefix fixates the ultrasound probe to the patient's chest, using two chest straps and a fixation device. The ultrasound probe position and angle may be altered with a relative high degree of freedom. We tested the Probefix for continuous echocardiographic imaging in 12 study subjects during supine and upright ergometer stress tests. One patient was unable to perform exercise and in two study subjects good quality images were not achieved. In the other patients (82%) a stable probe position was obtained, with subsequent good quality echocardiographic images during SE. We have demonstrated the feasibility of the Probefix support during ergometer tests in supine and upright positions and conclude that this external fixator may facilitate continuous monitoring of cardiac function in a group of patients.

  11. Managing type II and type IV Lauge-Hansen supination external rotation ankle fractures: current orthopaedic practice.

    PubMed

    Kosuge, D D; Mahadevan, D; Chandrasenan, J; Pugh, H

    2010-11-01

    Differentiating supination external rotation (SER) type II and IV ankle injuries is challenging in the absence of a medial malleolar fracture or talar shift on radiographs. The accurate differentiation between a stable SER-II from an unstable SER-IV injury would allow implementation of the appropriate management plan from diagnosis. The aim of this study was to ascertain the practice of orthopaedic surgeons in dealing with these injuries. A postal survey was undertaken on 216 orthopaedic consultants from three regions. In the presence of medial-sided clinical signs (tenderness, swelling, ecchymosis), 22% of consultants would perform surgical fixation. 53% would choose non-operative treatment and the majority would monitor these fractures through serial radiographs. The remaining 25% of consultants would perform an examination under anaesthesia (EUA; 15%), request stress radiographs (9%) or an MRI scan (1%). Without medial-sided signs, 85% would advocate non-operative treatment and, of these, 74% would perform weekly radiographs. Interestingly, 6% would perform immediate surgical fixation. Stress radiographs (6%) and EUAs (2%) were advocated in the remaining group of consultants. Foot and ankle surgeons utilised stress radiographs more frequently and were more likely to proceed to surgical fixation should talar shift be demonstrated. Clinical practice is varied amongst the orthopaedic community. This may lead to unnecessary surgery in SER-II injuries and delay in diagnosis and operative management of SER-IV injuries. We have highlighted the various investigative modalities available that may be used in conjunction with clinical signs to make a more accurate diagnosis.

  12. Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction.

    PubMed

    Huish, Eric G; Coury, John G; Ibrahim, Mohamed A; Trzeciak, Marc A

    2017-04-01

    The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of -0.3 mm (-2.1 to 3.1 mm), and volar tilt of 7.9° (-3° to 15°). One patient had intra-articular step-off greater than 2 mm. Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.

  13. Ilizarov external fixation versus plate osteosynthesis in the management of extra-articular fractures of the distal tibia.

    PubMed

    Fadel, Mohamed; Ahmed, Mohamed Ali; Al-Dars, Ahmed Mounir; Maabed, Mustafa Ahmed; Shawki, Hashem

    2015-03-01

    The purpose of this study was to evaluate the outcome of Ilizarov external fixation (IE) versus dynamic compression plate (PO) in the management of extra-articular distal tibial fractures. Between 2010 and 2011, extra-articular distal tibial fractures in 40 consecutive patients met the inclusion criteria. They were classified according to AO classification fracture type A (A1, A2, and A3). In a randomized method, two equal groups were managed using either IE or PO. PO was performed using open reduction and internal fixation (ORIF) and DCP through anterolateral approach. IE was done using Ilizarov frame. For the PO group, non-weight bearing ambulation was permitted on the second postoperative day but partial weight bearing was permitted according to the progression in union criteria clinically and radiologically. For the IE group, weight bearing started as tolerated from the first postoperative day. Physiotherapy and pin-site care was performed by the patient themselves. Modified Mazur ankle score was applied to IE (excellent 10, good 10) and in PO (excellent 2, good 8, poor 6). Data were statically analysed using (Mann-Whitney test). The rate of healing in the IE group (average 130) was higher than the PO (average 196.5); plus, there were no cases of delayed union or nonunion in the IE group (p value 0.003). It was found that IE compared with PO provides provision of immediate weight bearing as tolerated following postoperative recovery, irrespective of radiological or clinical healing with no infection, deformity or non-union.

  14. USE OF BIOCERAMICS IN FILLING BONE DEFECTS

    PubMed Central

    Garrido, Carlos Antõnio; Sampaio, Tania Clarete Fonseca Vieira Sales

    2015-01-01

    Objective: To present the results from using biological ceramics for filling bone defects resulting from post-traumatic or orthopedic injuries. Methods: Thirty-six patients with bone defects caused by trauma or orthopedic injury were evaluated. Nineteen patients were male (52.8%) and 17 were female (47.2%). Their ages ranged from 19 to 84 years, with a mean of 45.7 years and median of 37 years. Only patients with defects that required at least five grams of biological ceramic were included. Eighteen cases were classified as orthopedic: bone defects were observed in 11 cases of total hip arthroplasty; one case of primary total hip arthroplasty, due to coxarthrosis; five cases of femoral or tibial open wedge osteotomy; and one case of tarsal arthrodesis. There were 18 cases of trauma-related defects; uninfected pseudarthrosis, eight cases; recent fractures of the tibial plateau with compression of the spongy bone, three cases; and exposed fractures treated with external fixators, seven cases. The surgical technique consisted of curetting and debriding the injury until bone suitable for grafting was found. Biological ceramic was then used to fill the defect and some kind of fixation was applied. Results: Among the 36 patients evaluated, it was seen that 35 (97.2%) presented integration of the biological ceramic, while one case of open fracture treated with external fixation had poor integration of the biological ceramic. Conclusion: Treatment of bone defects of orthopedic or post-traumatic etiology using a phosphocalcium ceramic composed of hydroxyapatite was shown to be a practical, effective and safe method. PMID:27022576

  15. Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator.

    PubMed

    Tafazal, Suhayl; Madan, Sanjeev S; Ali, Farhan; Padman, Manoj; Swift, Simone; Jones, Stanley; Fernandes, James A

    2014-05-01

    The use of circular fixators for the treatment of tibial fractures is well established in the literature. The aim of this study was to compare the Ilizarov circular fixator (ICF) with the Taylor spatial frame (TSF) in terms of treatment results in consecutive patients with tibial fractures that required operative management. A retrospective analysis of patient records and radiographs was performed to obtain patient data, information on injury sustained, the operative technique used, time duration in frame, healing time and complications of treatment. The minimum follow-up was 24 months. Ten patients were treated with ICF between 2000 and 2005, while 15 patients have been treated with TSF since 2005. Two of the 10 treated with ICF and 5 of the 15 treated with TSF were open fractures. All patients went on to achieve complete union. Mean duration in the frame was 12.7 weeks for ICF and 14.8 weeks for the TSF group. Two patients in the TSF group had delayed union and required additional procedures including adjustment of fixator and bone grafting. There was one malunion in the TSF group that required osteotomy and reapplication of frame. There were seven and nine pin-site infections in the ICF and TSF groups, respectively, all of which responded to antibiotics. There were no refractures in either group. In an appropriate patient, both types of circular fixator are equally effective but have different characteristics, with TSF allowing for postoperative deformity correction. Of concern are the two cases of delayed union in the TSF group, all in patients with high-energy injuries. We feel another larger study is required to provide further clarity in this matter. Level II-comparative study.

  16. [Treatment of open tile type C pelvic fractures by open reduction and internal fixation through anterior and posterior approaches at early stage].

    PubMed

    Li, Baichuan

    2014-05-01

    To explore the effectiveness of open reduction and internal fixation through anterior and posterior approaches in treatment of open Tile type C pelvic fractures at early stage. Between January 2009 and April 2012, 12 patients with open Tile C pelvic fractures were treated. There were 7 males and 5 females, aged 6-53 years (median, 31 years). Of 12 cases, 4 were classified as Tile type C1, 6 as Tile type C2, and 2 as Tile type C3; 5 were rated as Gustilo type II and 7 as Gustilo type III. The injury severity score was 18-57 (mean, 37.2). The interval of injury and admission ranged from 15 minutes to 3 days (median, 50 minutes). The debridement and external fixation were performed at first stage; then open reduction and internal fixation were used through anterior approach (reconstruction plate) and posterior approach (cannulated lag screws). The vacuum sealing drainage was performed during treatment until the wounds healed. Delayed healing of incison was obtained in 12 cases because of wound infection. Anatomical reduction or approximate anatomical reduction was achieved in all 12 cases. The patients were followed up 3-39 months (median, 18 months). No loosening of internal fixation or fracture displacement was observed during follow-up. The fracture healing time was 7-13 weeks (mean, 9.7 weeks). At last follow-up, according to the Matta standard, the outcome was excellent in 10 cases and good in 2 cases; according to Majeed score, the results were excellent in 9 cases, good in 1, and poor in 2. Early internal fixation operation of open Tile type C pelvic fractures can effectively restore the pelvic anatomical structure and stability, reduce the complication, and achieve satisfactory effectiveness.

  17. Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation.

    PubMed

    Yu, Z; Zheng, L; Zhang, Y; Li, J; Ma, Bao'an

    2009-05-14

    This study was designed to evaluate the functional and radiological outcomes of patients with complex tibial plateau fractures treated with double-buttress plate fixation. Sixty five cases of complex (Schatzker type V and VI) tibial plateau fractures were treated with double-buttress plate fixation in our centre from September 2001 to September 2006 through two separate plate incisions. Fifty four patients were followed up for a period ranging from 12 to 48 months and evaluated for the functional and radiological outcomes by a series of standard questionnaire and measurement. Due to the good exposure without any extensive soft-tissue dissection of the double-buttress plate fixation, the fractures in all 54 patients were healed and the treatment achieved greater than 90% of satisfactory-to-excellent rates of reduction. The mean time of bone union was 15.4 weeks (range, 12-30 weeks), and the mean time of full weight-bearing was 18.7 weeks (range, 14-26 weeks). At the final follow-up visit, no patients showed knee instability; the mean range of motion was 107.6 degrees (range, 85 degrees -130 degrees ). For all patients, no statistically significant difference in the functional outcomes was observed between their 6-months and final follow-up visits; or in the radiological findings between their immediate postoperative and final follow-up examinations. Double-buttress plate fixation is a feasible treatment option for bilcondylar and complex tibial plateau fractures. Although technically demanding, it offers reliable stability without additional postoperative adjuvant external fixation, and at the same time avoids extensive soft tissue dissection, allowing the early painless range of motion.

  18. Review of techniques for monitoring the healing fracture of bones for implementation in an internally fixated pelvis.

    PubMed

    Wong, Lydia Chwang Yuh; Chiu, Wing Kong; Russ, Matthias; Liew, Susan

    2012-03-01

    Sacral fractures from high-impact trauma often cause instability in the pelvic ring structure. Treatment is by internal fixation which clamps the fractured edges together to promote healing. Healing could take up to 12 weeks whereby patients are bedridden to avoid hindrances to the fracture from movement or weight bearing activities. Immobility can lead to muscle degradation and longer periods of rehabilitation. The ability to determine the time at which the fracture is stable enough to allow partial weight-bearing is important to reduce hospitalisation time. This review looks into different techniques used for monitoring the fracture healing of bones which could lead to possible methods for in situ and non-invasive assessment of healing fracture in a fixated pelvis. Traditional techniques being used include radiology and CT scans but were found to be unreliable at times and very subjective in addition to being non in situ. Strain gauges have proven to be very effective for accurate assessment of fracture healing as well as stability for long bones with external fixators but may not be suitable for an internally fixated pelvis. Ultrasound provides in situ monitoring of stiffness recovery but only assesses local fracture sites close to the skin surface and has only been tested on long bones. Vibration analysis can detect non-uniform healing due to its assessment of the overall structure but may suffer from low signal-to-noise ratio due to damping. Impedance techniques have been used to assess properties of non-long bones but recent studies have only been conducted on non-biological materials and more research needs to be done before it can be applicable for monitoring healing in the fixated pelvis. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. The floating knee: a review on ipsilateral femoral and tibial fractures

    PubMed Central

    Muñoz Vives, Josep; Bel, Jean-Christophe; Capel Agundez, Arantxa; Chana Rodríguez, Francisco; Palomo Traver, José; Schultz-Larsen, Morten; Tosounidis, Theodoros

    2016-01-01

    In 1975, Blake and McBryde established the concept of ‘floating knee’ to describe ipsilateral fractures of the femur and tibia.1 This combination is much more than a bone lesion; the mechanism is usually a high-energy trauma in a patient with multiple injuries and a myriad of other lesions. After initial evaluation patients should be categorised, and only stable patients should undergo immediate reduction and internal fixation with the rest receiving external fixation. Definitive internal fixation of both bones yields the best results in almost all series. Nailing of both bones is the optimal fixation when both fractures (femoral and tibial) are extra-articular. Plates are the ‘standard of care’ in cases with articular fractures. A combination of implants are required by 40% of floating knees. Associated ligamentous and meniscal lesions are common, but may be irrelevant in the case of an intra-articular fracture which gives the worst prognosis for this type of lesion. Cite this article: Muñoz Vives K, Bel J-C, Capel Agundez A, Chana Rodríguez F, Palomo Traver J, Schultz-Larsen M, Tosounidis, T. The floating knee. EFORT Open Rev 2016;1:375-382. DOI: 10.1302/2058-5241.1.000042. PMID:28461916

  20. Functional significance of dinitrogen fixation in sustaining coral productivity under oligotrophic conditions

    PubMed Central

    Cardini, Ulisse; Bednarz, Vanessa N.; Naumann, Malik S.; van Hoytema, Nanne; Rix, Laura; Foster, Rachel A.; Al-Rshaidat, Mamoon M. D.; Wild, Christian

    2015-01-01

    Functional traits define species by their ecological role in the ecosystem. Animals themselves are host–microbe ecosystems (holobionts), and the application of ecophysiological approaches can help to understand their functioning. In hard coral holobionts, communities of dinitrogen (N2)-fixing prokaryotes (diazotrophs) may contribute a functional trait by providing bioavailable nitrogen (N) that could sustain coral productivity under oligotrophic conditions. This study quantified N2 fixation by diazotrophs associated with four genera of hermatypic corals on a northern Red Sea fringing reef exposed to high seasonality. We found N2 fixation activity to be 5- to 10-fold higher in summer, when inorganic nutrient concentrations were lowest and water temperature and light availability highest. Concurrently, coral gross primary productivity remained stable despite lower Symbiodinium densities and tissue chlorophyll a contents. In contrast, chlorophyll a content per Symbiodinium cell increased from spring to summer, suggesting that algal cells overcame limitation of N, an essential element for chlorophyll synthesis. In fact, N2 fixation was positively correlated with coral productivity in summer, when its contribution was estimated to meet 11% of the Symbiodinium N requirements. These results provide evidence of an important functional role of diazotrophs in sustaining coral productivity when alternative external N sources are scarce. PMID:26511052

Top