Sample records for external fixator removal

  1. [Domestic external fixator application in the treatment of limb deformities: 7 289 cases application report].

    PubMed

    Qin, S H; Guo, B F; Zheng, X J; Jiao, S F; Xia, H T; Peng, A M; Pan, Q; Zang, J C; Wang, Z J

    2017-09-01

    Objective: To discuss the clinical application and effects of domestic external fixator in the treatment of patients with malformations of limbs. Methods: A total of 7 289 patients with malformation of limbs who had been operated in Qin Sihe orthopedic surgery team from January 1989 to June 2016 were retrospective analyzed. The patients were treated with domestic external fixator, including 4 033 males and 3 256 females, aging from 2 to 82 years with a mean age of 23.4 years. There were 2 732 patients using Ilizarov external fixator, 4 713 patients using hybrid external fixator, 57 patients using monobrachial external fixator, 232 patients using Ilizarov external fixator and hybrid external fixator. The Ilizarov, hybrid and monobrachial external fixator were used in 67, 65 and 0 patients on the upper limbs and in 2 665, 4 616 and 57 patients on the lower limbs. There were 3 028 patients operated on the left limbs, 3 260 patients operated on the right limbs and 1 001 patients operated on the bilateral limbs. The top three types of diseases were sequelae of poliomyelitis, cerebral palsy and post-traumatic stress disorder peromely. Deformity types inclued talipes equinovarus, knee flexion deformity, cavus foot and so on. Results: All the patients were followed up for a period of 2.5 months to 22.4 years, with an average follow-up time of 5.4 years. All of the external fixators were used for single once, and there was no substitute for external fixator quality problem. All the patients were completed surgery goal until removing external fixation except 1 patient gave up treatment and 1 removed the fixator because of metal allergy. The common complications included wire or pin infection and joint movement limitation and so on. Conclusions: The domestic external fixator developed and produced based on the characteristics of Chinese limb deformity disability. The domestic external fixator can be used to treat kinds of limb deformities with the advantages of practical, economical, adjustable, universal and portable. The domestic external fixator could meet the clinical demand for fixation of the osteotomy end of the limbs, the correction of the deformity, the repair of the defects and the limb lengthening.

  2. [Effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation].

    PubMed

    Ge, Qihang; Wan, Chunyou; Liu, Yabei; Ji, Xu; Ma, Jihai; Cao, Haikun; Yong, Wei; Liu, Zhao; Zhang, Ningning

    2017-08-01

    To investigate the effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation. The data of 45 cases with tibial and fibular open fractures treated by Taylor space stent fixation who meet the selection criteria between January 2015 and June 2016 were retrospectively analysed. The patients were divided into trial group (23 cases) and control group (22 cases) according to whether the axial stress stimulation was performed after operation. There was no significant difference in gender, age, affected side, cause of injury, type of fracture, and interval time from injury to operation between 2 groups ( P >0.05). The axial stress stimulation was performed in trial group after operation. The axial load sharing ratio was tested, and when the value was less than 10%, the external fixator was removed. The fracture healing time, full weight-bearing time, and external fixator removal time were recorded and compared. After 6 months of external fixator removal, the function of the limb was assessed by Johner-Wruhs criteria for evaluation of final effectiveness of treatment of tibial shaft fractures. There were 2 and 3 cases of needle foreign body reaction in trial group and control group, respectively, and healed after symptomatic anti allergic treatment. All the patients were followed up 8-12 months with an average of 10 months. All the fractures reached clinical healing, no complication such as delayed union, nonunion, or osteomyelitis occurred. The fracture healing time, full weight-bearing time, and external fixator removal time in trial group were significantly shorter than those in control group ( P <0.05). After 6 months of external fixator removal, the function of the limb was excellent in 13 cases, good in 6 cases, fair in 3 cases, and poor in 1 case in trial group, with an excellent and good rate of 82.6%; and was excellent in 5 cases, good in 10 cases, fair in 4 cases, and poor in 3 cases in control group, with an excellent and good rate of 68.2%, showing significant difference between 2 groups ( Z =-2.146, P =0.032). The axial stress stimulation of Taylor space stent fixation can promote the healing of tibial and fibular open fractures and promote local bone formation at fracture site.

  3. Objective guidelines for removing an external fixator after tibial lengthening using pixel value ratio: a pilot study.

    PubMed

    Zhao, Li; Fan, Qing; Venkatesh, K P; Park, Man S; Song, Hae Ryong

    2009-12-01

    During limb lengthening over an intramedullary nail, decisions regarding external fixator removal and weightbearing depend on the amount of callus seen at the lengthening area on radiographs. However, this method is subjective and objective evaluation of the amount of callus likely would minimize nail or interlocking screw breakage and refracture after fixator removal. We asked how many cortices with full corticalization of the newly formed bone at the lengthening area are needed to allow fixator removal and full weightbearing and how to radiographically determine the stage of corticalization. We retrospectively reviewed 17 patients (34 lengthenings) who underwent bilateral tibial lengthenings over an intramedullary nail. The average gain in length was 7.2 +/- 3.4 cm. We determined the pixel value ratio (ratio of pixel value of regenerate versus the mean pixel value of adjacent bone) of the lengthened area on radiographs. There were no nail or screw breakage and refracture. Partial weightbearing with crutches was permitted when the pixel value ratio was 1 in two cortices and full weightbearing without crutches was permitted when the pixel value ratio was 1 in three cortices. The pixel value ratio on radiographs can be an objective parameter for callus measurement and may provide guidelines for the timing of external fixator removal. We cannot determine from our limited data the minimum pixel value in how many cortices would suggest safe removal, but we can say our criteria were not associated with subsequent refracture.

  4. Treatment of femoral shaft fractures with monoaxial external fixation in polytrauma patients

    PubMed Central

    Testa, Gianluca; Aloj, Domenico; Ghirri, Alessandro; Petruccelli, Eraclite; Pavone, Vito; Massé, Alessandro

    2017-01-01

    Background: Femoral shaft fractures, typical in younger people, are often associated with polytrauma followed by traumatic shock. In these situations, despite intramedullary nailing being the treatment of choice, external fixation could be used as the definitive treatment. The aim of this study is to report evidence regarding definitive treatment of femoral shaft fractures with monoaxial external fixation. Methods: Between January 2006 and December 2015, 83 patients with 87 fractures were treated at the Department of Orthopaedics and Traumatology CTO of Turin, with a monoaxial external fixation device. Mean age at surgery, type of fracture, mean follow-up, time and modalities of treatment, non-weight bearing period, average healing, external fixation removal time, and complications were reported. Results: The average patient age was 31.43±15.19 years. In 37 cases (42.53%) the right femur was involved. 73 (83.91%) fractures were closed, and 14 (16.09%) were open. The average follow-up time was 61.07±21.86 weeks.  In 68 (78.16%) fractures the fixation was carried out in the first 24 hours, using a monoaxial external fixator. In the remaining 19 cases, the average delay was 6.80±4.54 days. Mean non-weight bearing time was 25.82±27.66 days (ranging from 0 to 120). The 87 fractures united at an average of 23.60±11.37 weeks (ranging from 13 to 102). The external fixator was removed after an average of 33.99±14.33 weeks (ranging from 20 to 120). Reported complications included 9.19% of delayed union, 1.15% of septic non-union, 5.75% of malunion, and 8.05% cases of loss of reduction. Conclusions: External fixation of femoral shaft fractures in polytrauma is an ideal method for definitive fracture stabilization, with minimal additional operative trauma and an acceptable complication rate. PMID:28928953

  5. [Results of femoral lengthening over an intramedullary nail and external fixator].

    PubMed

    Jasiewicz, Barbara; Kacki, Wojciech; Tesiorowski, Maciej; Potaczek, Tomasz

    2008-01-01

    Current techniques of operative limb lengthening usually are based on distraction osteogenesis. One of the techniques is limb lengthening over an intramedullary nail. The goal of this study is to evaluate the results of femoral lengthening over an intramedullary nail. Between 1999 and 200619 femoral "over nail" lengthenings were performed. There were 7 males and 12 females. Mean patients' age at surgery was 15.8 years, and mean initial femoral shortening was 5.1 cm. Operative technique consisted of one-stage implantation of intramedullary nail and external fixator. Ilizarov apparatus was used in 9 patients, monolateral fixator in 10 cases--ORTHOFIX in 9 patients, Wagner fixator--in 1 patient. Intramedullary nail was locked proximally with screws or Schanz pins from external fixator. After distraction phase, external fixator was removed and distal locking screws were applied. Evaluation criteria: obtained lengthening, time of external fixator, treatment time, healing index, external fixation index, range of motion in hip and knee joints and complications according to Paley. The mean lengthening was 4.6 cm, and mean distraction time was 66.6 days. Mean time of external fixation was 115.5 days, and external fixation index was 26.2 days for centimeter. Healing index was 36.9 days for centimeter. In cases with monolateral fixator, healing index did not differ with the whole group. During treatment 18 complications occurred, for a rate of 0.9 complication per segment. Lengthening over an intramedullary nail reduces the time of external fixator. Over nail femoral lengthening can prevent axis deviation following regenerate bending. Complication rate is similar to lengthenings with the classic Ilizarov technique. There are no differences in the treatment time in relation to the type of external fixator.

  6. An Efficient and Reproducible Protocol for Distraction Osteogenesis in a Rat Model Leading to a Functional Regenerated Femur.

    PubMed

    Pithioux, Martine; Roseren, Flavy; Jalain, Christian; Launay, Franck; Charpiot, Philippe; Chabrand, Patrick; Roffino, Sandrine; Lamy, Edouard

    2017-10-23

    This protocol describes the use of a newly developed external fixator for distraction osteogenesis in a rat femoral model. Distraction osteogenesis (DO) is a surgical technique leading to bone regeneration after an osteotomy. The osteotomized extremities are moved away from each other by gradual distraction to reach the desired elongation. This procedure is widely used in humans for lower and upper limb lengthening, treatment after a bone nonunion, or the regeneration of a bone defect following surgery for bone tumor excision, as well as in maxillofacial reconstruction. Only a few studies clearly demonstrate the efficiency of their protocol in obtaining a functional regenerated bone, i.e., bone that will support physiological weight-bearing without fracture after removal of the external fixator. Moreover, protocols for DO vary and reproducibility is limited by lack of information, making comparison between studies difficult. The aim of this study was to develop a reproducible protocol comprising an appropriate external fixator design for rat limb lengthening, with a detailed surgical technique that permits physiological weight-bearing by the animal after removal of the external fixator.

  7. Correction of complex equino cavo varus foot deformity in skeletally mature patients by Ilizarov external fixation versus staged external-internal fixation.

    PubMed

    Emara, Khaled; El Moatasem, El Hussein; El Shazly, Ossama

    2011-12-01

    Complex foot deformity is a multi-planar foot deformity with many etiologic factors. Different corrective procedures using Ilizarov external fixation have been described which include, soft tissue release, V-osteotomy, multiple osteotomies and triple fusion. In this study we compare the results of two groups of skeletally mature patients with complex foot deformity who were treated by two different protocols. The first group (27 patients, 29 feet) was treated by triple fusion fixed by Ilizarov external fixator until union. The second group (29 patients, 30 feet), was treated by triple fusion with initial fixation by Ilizarov external fixation until correction of the deformity was achieved clinically, and then the Ilizarov fixation was replaced by internal fixation using percutaneous screws. Both groups were compared as regard the surgical outcome and the incidence of complications. There was statistically significant difference between the two groups regarding duration of external fixation and duration of casting with shorter duration in the group 2. Also there was statistically significant difference between both groups regarding pin tract infection with less incidence in group 2. Early removal of Ilizarov external fixation after correction of the deformity and percutaneous internal fixation using 6.5 cannulated screws can shorten the duration of treatment and be more comfortable for the patient with a low risk of recurrence or infection. Copyright © 2010 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  8. Arthrodesis for failed knee arthroplasty. A report of 20 cases.

    PubMed

    Knutson, K; Lindstrand, A; Lidgren, L

    1985-01-01

    Twenty consecutive patients treated by arthrodesis for failed knee arthroplasty are reviewed. Eight hinged, five stabilised and seven compartmental prostheses were removed, for infection (15 cases), loosening (4) and instability (1). One patient refused a second-stage operation but the remainder gained sound fusion. Infected knees had a two-stage procedure with temporary insertion of gentamicin-loaded beads after removal of the prosthesis; all infections healed. Six arthrodeses using a Hoffmann-Vidal external fixator resulted in two temporary failures. One Ace-Fischer external fixation was successful. Of 10 primary attempts at arthrodesis with an intramedullary Küntscher nail, nine were successful; the tenth fused after two more attempts by the same method. The two failures of external fixation and two failures after Charnley single-frame compression done elsewhere were successfully fused with intramedullary nails. Delayed union in three cases fused after prolonged fixation and repeated bone grafts. The indications for and methods of arthrodesis after failed knee arthroplasty are discussed.

  9. Limb Lengthening and Then Insertion of an Intramedullary Nail: A Case-matched Comparison

    PubMed Central

    Kleinman, Dawn; Fragomen, Austin T.; Ilizarov, Svetlana

    2008-01-01

    Distraction osteogenesis is an effective method for lengthening, deformity correction, and treatment of nonunions and bone defects. The classic method uses an external fixator for both distraction and consolidation leading to lengthy times in frames and there is a risk of refracture after frame removal. We suggest a new technique: lengthening and then nailing (LATN) technique in which the frame is used for gradual distraction and then a reamed intramedullary nail inserted to support the bone during the consolidation phase, allowing early removal of the external fixator. We performed a retrospective case-matched comparison of patients lengthened with LATN (39 limbs in 27 patients) technique versus the classic (34 limbs in 27 patients). The LATN group wore the external fixator for less time than the classic group (12 versus 29 weeks). The LATN group had a lower external fixation index (0.5 versus 1.9) and a lower bone healing index (0.8 versus 1.9) than the classic group. LATN confers advantages over the classic method including shorter times needed in external fixation, quicker bone healing, and protection against refracture. There are also advantages over the lengthening over a nail and internal lengthening nail techniques. Level of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18800209

  10. Advantages of the Ilizarov external fixation in the management of intra-articular fractures of the distal tibia

    PubMed Central

    Vasiliadis, Elias S; Grivas, Theodoros B; Psarakis, Spyridon A; Papavasileiou, Evangelos; Kaspiris, Angelos; Triantafyllopoulos, Georgios

    2009-01-01

    Background Treatment of distal tibial intra-articular fractures is challenging due to the difficulties in achieving anatomical reduction of the articular surface and the instability which may occur due to ligamentous and soft tissue injury. The purpose of this study is to present an algorithm in the application of external fixation in the management of intra-articular fractures of the distal tibia either from axial compression or from torsional forces. Materials and methods Thirty two patients with intra-articular fractures of the distal tibia have been studied. Based on the mechanism of injury they were divided into two groups. Group I includes 17 fractures due to axial compression and group II 15 fractures due to torsional force. An Ilizarov external fixation was used in 15 patients (11 of group I and 4 of group II). In 17 cases (6 of group I and 11 of group II) a unilateral hinged external fixator was used. In 7 out of 17 fractures of group I an additional fixation of the fibula was performed. Results All fractures were healed. The mean time of removal of the external fixator was 11 weeks for group I and 10 weeks for group II. In group I, 5 patients had radiological osteoarthritic lesions (grade III and IV) but only 2 were symptomatic. Delayed union occurred in 3 patients of group I with fixed fibula. Other complications included one patient of group II with subluxation of the ankle joint after removal of the hinged external fixator, in 2 patients reduction found to be insufficient during the postoperative follow up and were revised and 6 patients had a residual pain. The range of ankle joint motion was larger in group II. Conclusion Intra-articular fractures of the distal tibia due to axial compression are usually complicated with cartilaginous problems and are requiring anatomical reduction of the articular surface. Fractures due to torsional forces are complicated with ankle instability and reduction should be augmented with ligament repair, in order to restore normal movement of talus against the mortise. Both Ilizarov and hinged external fixators are unable to restore ligamentous stability. External fixation is recommended only for fractures of the ankle joint caused by axial compression because it is biomechanically superior and has a lower complication rate. PMID:19754962

  11. Suture Button Fixation Versus Syndesmotic Screws in Supination-External Rotation Type 4 Injuries: A Cost-Effectiveness Analysis.

    PubMed

    Neary, Kaitlin C; Mormino, Matthew A; Wang, Hongmei

    2017-01-01

    In stress-positive, unstable supination-external rotation type 4 (SER IV) ankle fractures, implant selection for syndesmotic fixation is a debated topic. Among the available syndesmotic fixation methods, the metallic screw and the suture button have been routinely compared in the literature. In addition to strength of fixation and ability to anatomically restore the syndesmosis, costs associated with implant use have recently been called into question. This study aimed to examine the cost-effectiveness of the suture button and determine whether suture button fixation is more cost-effective than two 3.5-mm syndesmotic screws not removed on a routine postoperative basis. Economic and decision analysis; Level of evidence, 2. Studies with the highest evidence levels in the available literature were used to estimate the hardware removal and failure rates for syndesmotic screws and suture button fixation. Costs were determined by examining the average costs for patients who underwent surgery for unstable SER IV ankle fractures at a single level-1 trauma institution. A decision analysis model that allowed comparison of the 2 fixation methods was developed. Using a 20% screw hardware removal rate and a 4% suture button hardware removal rate, the total cost for 2 syndesmotic screws was US$20,836 and the total effectiveness was 5.846. This yielded a total cost of $3564 per quality-adjusted life-year (QALY) over an 8-year time period. The total cost for suture button fixation was $19,354 and the total effectiveness was 5.904, resulting in a total cost of $3294 per QALY over the same time period. A sensitivity analysis was then conducted to assess suture button fixation costs as well as screw and suture button hardware removal rates. Other possible treatment scenarios were also examined, including 1 screw and 2 suture buttons for operative fixation of the syndesmosis. To become more cost-effective, the screw hardware removal rate would have to be reduced to less than 10%. Furthermore, fixation with a single suture button continued to be the dominant treatment strategy compared with 2 suture buttons, 1 screw, and 2 screws for syndesmotic fixation. This cost-effectiveness analysis suggests that for unstable SER IV ankle fractures, suture button fixation is more cost-effective than syndesmotic screws not removed on a routine basis. Suture button fixation was a dominant treatment strategy, because patients spent on average $1482 less and had a higher quality of life by 0.058 QALYs compared with patients who received fixation with 2 syndesmotic screws. Assuming that functional outcomes and failure rates were equivalent, screw fixation only became more cost-effective when the screw hardware removal rate was reduced to less than 10% or when the suture button cost exceeded $2000. In addition, fixation with a single suture button device proved more cost-effective than fixation with either 1 or 2 syndesmotic screws.

  12. The computer-aided parallel external fixator for complex lower limb deformity correction.

    PubMed

    Wei, Mengting; Chen, Jianwen; Guo, Yue; Sun, Hao

    2017-12-01

    Since parameters of the parallel external fixator are difficult to measure and calculate in real applications, this study developed computer software that can help the doctor measure parameters using digital technology and generate an electronic prescription for deformity correction. According to Paley's deformity measurement method, we provided digital measurement techniques. In addition, we proposed an deformity correction algorithm to calculate the elongations of the six struts and developed a electronic prescription software. At the same time, a three-dimensional simulation of the parallel external fixator and deformed fragment was made using virtual reality modeling language technology. From 2013 to 2015, fifteen patients with complex lower limb deformity were treated with parallel external fixators and the self-developed computer software. All of the cases had unilateral limb deformity. The deformities were caused by old osteomyelitis in nine cases and traumatic sequelae in six cases. A doctor measured the related angulation, displacement and rotation on postoperative radiographs using the digital measurement techniques. Measurement data were input into the electronic prescription software to calculate the daily adjustment elongations of the struts. Daily strut adjustments were conducted according to the data calculated. The frame was removed when expected results were achieved. Patients lived independently during the adjustment. The mean follow-up was 15 months (range 10-22 months). The duration of frame fixation from the time of application to the time of removal averaged 8.4 months (range 2.5-13.1 months). All patients were satisfied with the corrected limb alignment. No cases of wound infections or complications occurred. Using the computer-aided parallel external fixator for the correction of lower limb deformities can achieve satisfactory outcomes. The correction process can be simplified and is precise and digitized, which will greatly improve the treatment in a clinical application.

  13. Ilizarov bone transport versus fibular graft for reconstruction of tibial bone defects in children.

    PubMed

    Abdelkhalek, Mostafa; El-Alfy, Barakat; Ali, Ayman M

    2016-11-01

    The aim of this study was to compare the results of treatment of segmental tibial defects in the pediatric age group using an Ilizarov external fixator versus a nonvascularized fibular bone graft. This study included 24 patients (age range from 5.5 to 15 years) with tibial bone defects: 13 patients were treated with bone transport (BT) and 11 patients were treated with a nonvascularized fibular graft (FG). The outcome parameters were bone results (union, deformity, infection, leg-length discrepancy) and functional results: external fixation index and external fixation time. In group A (BT), one patient developed refracture at the regenerate site, whereas, in group B (FG), after removal of the external fixator, one of the FGs developed a stress fracture. The external fixator time in group A was 10.7 months (range 8-14.5) versus 7.8 months (range 4-11.5 months) in group B (FG). In group A (BT), one patient had a limb-length discrepancy (LLD), whereas, in group B (FG), three patients had LLD. The functional and bone results of the Ilizarov BT technique were excellent in 23.1 and 30.8%, good in 38.5 and 46.2, fair in 30.8 and 15.4, and poor in 7.6 and 7.6%, respectively. The poor functional result was related to the poor bone result because of prolonged external fixator time resulting in significant pain, limited ankle motion, whereas the functional and bone results of fibular grafting were excellent in 9.1 and 18.2%, good in 63.6 and 45.5%, fair in 18.2 and 27.2%, and poor in 9.1 and 9.1%, respectively. Segmental tibial defects can be effectively treated with both methods. The FG method provides satisfactory results, with early removal of the external fixator. However, it had a limitation in patients with severe infection and those with LLD. Also, it requires a long duration of limb bracing until adequate hypertrophy of the graft. The Ilizarov method has the advantages of early weight bearing, treatment of postinfection bone defect in a one-stage surgery, and the possibility to treat the associated LLD. However, it has a long external fixation time.

  14. A theoretical analysis and finite element simulation of fixator-bone system stiffness on healing progression.

    PubMed

    Li, Jianfeng; Zhao, Xia; Hu, Xiaojie; Tao, Chunjing; Ji, Run

    2018-03-01

    The unilateral external fixator has become a quick and easy application for fracture stabilization of the extremities; the main value for evaluation of mechanical stability of the external fixator is stiffness. The stiffness property of the external fixator affects the local biomechanical environment of fractured bone. In this study, a theoretical model with changing Young's modulus of the callus is established by using the Castigliano's theory, investigating compression stiffness, torsional stiffness and bending stiffness of the fixator-bone system during the healing process. The effects of pin deviation angle on three stiffness methods are also investigated. In addition, finite element simulation is discussed regarding the stress distribution between the fixator and bone. The results reveal the three stiffness evaluation methods are similar for the fixator-bone system. Finite element simulation shows that with increased healing time, the transmission of the load between the fixator and bone are different. In addition, the finite element analyses verify the conclusions obtained from the theoretical model. This work helps orthopedic doctors to monitor the progression of fracture healing and determine the appropriate time for removal of a fixation device and provide important theoretical methodology.

  15. Evaluation of functional outcome of pilon fractures managed with limited internal fixation and external fixation: A prospective clinical study.

    PubMed

    Meena, Umesh Kumar; Bansal, Mahesh Chand; Behera, Prateek; Upadhyay, Rahul; Gothwal, Gyan Chand

    2017-11-01

    The management of pilon fractures is controversial primarily due to the high rate of complications irrespective of the mode of treatment. Limited internal fixation with external fixation is associated with minimal soft tissue handling. This may reduce the chances of wound dehiscence and infection. This study was designed to evaluate the functional and clinical outcomes in patients treated with limited internal fixation combined with external fixation in pilon fractures. This study was conducted as a prospective clinical study on 56 skeletally mature patients with closed fractures with poor skin condition, and with open grade 1 and grade 2 distal tibial intra-articular fractures. All patients were treated with combined limited internal fixation and ankle spanning external fixation. All fractures in this series united with an average time period of union of 18.3weeks (ranging from 13 weeks to 30 weeks). There was no non-union in any case. There was malunion in 4 cases, varus malunion (>5 degree) in 2 cases and recurvatum in another 2 cases). Excellent to good functional results were observed in 88% cases based on the modified Ovadia and Beals score. The mean ankle dorsiflexion and planter flexion movements were 10.2±5.3 degrees and 27.4±7.2 degrees respectively. infections occurred in 6 patients which included 4 pin tract infections and 2 superficial wound infection, all 6 healed after removal of pin tract and with oral antibiotics. The technique of combined external fixation with internal fixation is safe and effective management option for intra-articular distal tibial fractures.

  16. Bacteria on External Fixators: Which Prep is Best?

    DTIC Science & Technology

    2012-01-01

    aureus (lux). After 12 hours in the broth, a sufficient time to allow biofilm formation ,11 the constructs were individually removed and baseline imaging...difference when cleansing components consisting of stainless steel and alumi- num.15–17 We also found that a simulated external fixator adjustment exposed...Albert E, et al. Direct continuous method for monitoring biofilm infection in a mouse model. Infect Immun. 2003;71: 882–890. 11. Charles CA, Ricotti CA

  17. Management of Complete Talocrural Luxations by Selective Talocrural Arthrodesis using Hybrid Transarticular External Skeletal Fixation in Dogs.

    PubMed

    Yardımcı, Cenk; Önyay, Taylan; İnal, Kamil S; Özbakır, Deniz B; Özak, Ahmet

    2018-06-16

     This article presents a novel surgical technique in the management of open complete talocrural luxations and evaluates the results, and clinical benefits with its routine clinical utilization.  Retrospective study.  Seventeen medium- or large-breed client-owned dogs of different breed, age and sex with complete talocrural luxations and radiographic follow-up of at least 24 weeks duration.  Selective talocrural arthrodesis was performed by using a hybrid transarticular external skeletal fixator frame. Clinical and radiographical evaluation was performed regarding the lesion, concomitant injury, duration of the surgery, time to first use of the limb, fixator removal time, complications and clinical outcomes.  Dogs started to use the injured limb between postoperative days 1 to 11. Pin or wire tract related complications were observed in all dogs. Time to fixator removal ranged from 57 to 90 days with a median of 73 days. All of the operated joints with an exception of one dog resulted in talocrural fusion. Mid-term clinical outcomes score was regarded as excellent in 13/17 dogs, good in 3/17 dogs and poor in 1/17 dogs subject to authors' evaluation.  A transarticular hybrid external fixator may allow early use of postoperative limb with an excellent patient compliance and is well tolerated as well. The technique showed a promising opportunity of providing favourable limb use. Schattauer GmbH Stuttgart.

  18. Regenerate bone fracture rate following femoral lengthening in paediatric patients

    PubMed Central

    Burke, N. G.; Cassar-Gheiti, A. J.; Tan, J.; McHugh, G.; O’Neil, B. J.; Noonan, M.; Moore, D.

    2017-01-01

    Abstract Purpose Femoral lengthening using a circular or mono-lateral frame is a commonly used technique. Fracture at the site of the regenerate bone is a major concern especially following removal of the external fixator. This aim of this study was to assess the rate of fracture of the regenerate bone in this single surgeon series of paediatric patients and determine potential risk factors. Methods Retrospective review of all the femoral lengthening performed by the senior author was performed. The medical and physiotherapy notes were reviewed. The gender, age at time of surgery, disease aetiology, total days in the external fixator and length of the new regenerate bone were recorded. Patients who sustained a regenerate fracture were identified. Results A total of 176 femoral lengthening procedures were performed on 108 patients. Eight regenerate fractures occurred in seven patients (4.5%). The mechanism of injury was a fall in five cases and during physiotherapy in three cases. The regenerate fracture occurred a median number of nine days following removal of frame. There was no significant difference between gender, age at time of surgery, total time in external fixator between those who sustained a regenerate fracture and those patients who did not. A significant difference was noted between the amount of lengthening between the ‘regenerate fracture group’ and the ‘no fracture group’ (50 mm vs 38 mm, respectively; p = 0.029). There was no association between disease aetiology and risk of regenerate fracture. Conclusions Femoral lengthening of more than 50 mm increases the risk of a fracture at the regenerate site regardless of the disease aetiology. We recommend avoidance of aggressive physiotherapy for the initial four weeks following external fixator removal. PMID:28828065

  19. [Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures].

    PubMed

    Zhang, Jian; Lin, Xu; Zhong, Zeli; Wu, Chao; Tan, Lun

    2017-07-01

    To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups ( P >0.05). There was no significant difference in operation time and hospitalization stay between 2 groups ( P >0.05). But the intraoperative blood loss in group A was significantly less than that in group B ( P <0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B ( P <0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference ( χ 2 =0.055, P =0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups ( χ 2 =0.056, P =0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups ( t =-0.028, P =0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B ( P <0.05). The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

  20. Rapid maxillary distraction protocol utilizing the halo distraction system and rigid internal fixation.

    PubMed

    Baker, Stephen B; Reid, Russell R; Burkey, Brooke; Bartlett, Scott P

    2007-09-01

    To shorten head frame wear time associated with external halo distraction (HD), we have adapted a protocol for maxillary distraction with the halo system that integrates plate fixation. All patients had a history of cleft lip and/or palate and maxillary retrusion > or = 8 mm. Five patients treated with this protocol and followed for at least 1 year were included in this study. The protocol included a 3-day latency period, variable maxillary distraction, and removal of the halo device with simultaneous rigid internal fixation. Two patients had a variable period of maxillomandibular fixation (MMF), which maintained the maxillary advancement and idealized intercuspal position while permitting further callus maturation. Cephalographs were obtained preoperatively, immediately following distractor removal, and 1 year after rigid internal fixation. The mean age at time of surgery was 18.7 years. The maxillary deficiency ranged from 8 to 15 mm (mean = 10.6 mm). All five patients demonstrated excellent occlusion. Cephalometric analysis 1-year post rigid internal fixation revealed minimal (<1 mm) skeletal relapse. Rapid maxillary distraction followed by MMF to maintain maxillary advancement may reduce halo device wear to 1 to 2 weeks. MMF optimizes occlusion by forcing the maxillary teeth into maximal intercuspal position. Rigid fixation is not only associated with less long-term relapse compared to nonrigid forms of fixation, but also minimizes the incidence of nonunion. This treatment protocol provides the advancement possible with distraction osteogenesis and the accuracy of orthognathic surgery, thereby minimizing external head frame wear.

  1. Removable splint with locking attachments for maxillary distraction osteogenesis with the RED system.

    PubMed

    Suzuki, E Y; Suzuki, B

    2007-12-01

    The external traction hooks of the intraoral splint used to control traction forces applied to the maxilla with the rigid external distraction system represent a major barrier to surgical procedures. The purpose of this article is to introduce a removable intraoral splint with locking attachments that can be placed post-surgically immediately before distraction, facilitating surgery and consequently reducing the operative time. Fifteen cleft lip and palate patients underwent maxillary distraction osteogenesis using a rigid external distraction device in combination with the proposed removable splint that was fixed onto the maxillary teeth to provide anchorage. Initial records showed severe maxillary hypoplasia and negative overjet. The removable splint was fabricated using 1.5-mm diameter stainless-steel rigid orthodontic wires soldered to the locking attachments (Y&B Products LP, Chiang Mai, Thailand), making possible its placement post-surgically. Stable splint fixation was achieved prior to the distraction procedure and the desired treatment goals were reached. No complications inserting or removing the splint post-surgically, including pain or discomfort, were observed. The use of the removable splint with locking attachments has proved to be a highly effective fixation approach to manage the severely hypoplastic maxilla, eliminating lip constraints resulting from scarring, and allowing for easier, more deliberate and careful dissection.

  2. [Tensile strength of bone fixation of hydroxyapatite coated Schanz screws of the Heidelberg External Fixation System (HEFS)--comparative torque measurements in clinical use and in cadaver tibia].

    PubMed

    Placzek, R; Deuretzbacher, G; Meiss, A L

    2002-12-01

    It is claimed in the literature that hydroxyapatite(HA)-coated screws of external fixators have superior fixation strength in bone, which is postulated to lead to a substantial decrease in loosening and infection rates. We report on a study of the maximum torque values developed while inserting and removing 30 HA-coated Schanz screws of 8 Heidelberg external fixation systems applied to the tibia to correct leg length differences and axial deformities. The infection rate was determined in accordance with defined criteria, and was found to be about 20% for the HA-coated screws. Screws without infection showed an extraction torque above insertion torque, screws with infection an extraction torque below. A significant correlation (p = 0.05) was seen between infection and decrease in fixation strength (quotient: loosening torque/tightening torque). To exclude the impact of such biological processes as osteointegration and bone remodelling, the clinical results were compared with the torques measured for coated and uncoated Schanz screws in a human cadaveric tibia. A significantly higher fixation strength in bone was found for HA-coated screws in comparison with uncoated screws (p = 0.002). These data warrant a clinical study directly comparing HA-coated and uncoated Schanz screws.

  3. Limb lengthening over plate

    PubMed Central

    Kulkarni, Ruta; Singh, Nishant; Kulkarni, Govind S; Kulkarni, Milind; Kulkarni, Sunil; Kulkarni, Vidisha

    2012-01-01

    Background: The limb lengthening over plate eliminates the associated risk of infection with limb lengthening over intramedullary nail. We present our experience of limb lengthening in 15 patients with a plate fixed on the proximal segment, followed by corticotomy and application of external fixator. Materials and Methods: 15 patients (7 females, 8 males) were included in this consecutive series. The average age was 18.1 years (range 8–35 years). Fifteen tibiae and one femur were lengthened in 15 patients. Lengthening was achieved at 1 mm/day followed by distal segment fixation with three or four screws on reaching the target length. Results: The preoperative target length was successfully achieved in all patients at a mean of 4.1 cm (range 1.8–6.5 cm). The mean duration of external fixation was 75.3 days (range 33–116 days) with the mean external fixation index at 19.2 days/cm (range 10.0–38.3 days/cm). One patient suffered deep infection up to the plate, three patients had mild procurvatum deformities, and one patient developed mild tendo achilles contracture. Conclusion: Lengthening over a plate allows early removal of external fixator and eliminates the risk of creating deep intramedullary infection as with lengthening over nail. Lengthening over plate is also applicable to children with open physis. PMID:22719123

  4. Rostral mandibular fracture repair in a pet bearded dragon (Pogona vitticeps).

    PubMed

    Nau, Melissa R; Eshar, David

    2018-04-15

    CASE DESCRIPTION A 2-year-old male bearded dragon (Pogona vitticeps) was evaluated because of a traumatic mandibular fracture. CLINICAL FINDINGS An open comminuted fracture of the rostral aspect of the right mandible was evident, with a fragment of bone exposed and dorsally displaced. Whole-body radiography revealed no evidence of additional injury. Other findings were unremarkable, except for moderate anemia (PCV, 19%). TREATMENT AND OUTCOME The fracture fragments were stabilized with 2 crossed 36-gauge interfragmentary wire loops. An external fixator device was fashioned from four 25-gauge needles inserted at alternating angles through the fracture fragments; plastic IV fluid line tubing filled with dental acrylic was used as a connecting bar. One day after surgery, the lizard had regained its typical activity level and appetite. Body weight was measured and the external fixator was inspected 1 week after surgery and monthly thereafter. Three months after initial injury, the fracture was stable, radiography revealed bony callus formation at the fracture site, and the external fixator was removed. Recheck radiography performed 5.5 months after initial injury revealed complete osseous union of the fracture fragments, and the interfragmentary wires were removed. CLINICAL RELEVANCE Surgical management of the traumatic comminuted mandibular fracture in this bearded dragon by means of a combination of internal and external fixation resulted in complete healing of the mandible and restoration of function. Management of this complicated fracture was achieved with the aid of readily available and inexpensive supplies in a clinical setting, which may be useful to other clinicians in the management of similar cases.

  5. Subtalar distraction osteogenesis for posttraumatic arthritis following intra-articular calcaneal fractures.

    PubMed

    Fan, Wei-Li; Sun, Hong-Zhen; Wu, Si-Yu; Wang, Ai-Min

    2013-03-01

    The most common treatment for old calcaneal fractures accompanied by subtalar joint injury is the use of subtalar in situ arthrodesis and subtalar distraction bone-block arthrodesis or osteotomy. This article describes the introduction of a novel surgical treatment, gradual subtalar distraction with external fixation and restoration of the calcaneal height, and presents an assessment of its efficacy. The protruding lateral calcaneus and the articular surfaces and subchondral bone of the posterior facet of the subtalar joint were surgically removed. An external fixator, attached with 2 pins in the subcutaneous tibia and 2 pins in the posterolateral calcaneus, was used to fix the subtalar joint for 7 to 10 days followed by gradual subtalar distraction at 1 mm/d. The lengthening procedure was stopped when the calcaneal height was restored according to radiography. The external fixator was removed after bone fusion. Seven cases of old calcaneal fractures accompanied by severe subtalar joint injury (8 feet) were treated using this method. Average follow-up was 14.3 months (range, 7-36 months). In all 7 cases (1 case of both feet), the postoperative wound healed primarily. The calcaneal heights of all 8 feet were partially restored. Subtalar joint bone fusion was completed within 4 to 6 months after the operation. The average preoperative American Orthopedic Foot & Ankle Society (AOFAS) hindfoot score was 25.3, and the average postoperative AOFAS score was 76.3. Subtalar distraction osteogenesis with external fixation was a novel and effective method for the treatment of old calcaneal fractures accompanied by severe subtalar joint injury in this small group of patients. Level IV, retrospective case series.

  6. Biomechanical monitoring of healing bone based on acoustic emission technology.

    PubMed

    Hirasawa, Yasusuke; Takai, Shinro; Kim, Wook-Cheol; Takenaka, Nobuyuki; Yoshino, Nobuyuki; Watanabe, Yoshinobu

    2002-09-01

    Acoustic emission testing is a well-established method for assessment of the mechanical integrity of general construction projects. The purpose of the current study was to investigate the usefulness of acoustic emission technology in monitoring the yield strength of healing callus during external fixation. Thirty-five patients with 39 long bones treated with external fixation were evaluated for fracture healing by monitoring load for the initiation of acoustic emission signal (yield strength) under axial loading. The major criteria for functional bone union based on acoustic emission testing were (1) no acoustic emission signal on full weightbearing, and (2) a higher estimated strength than body weight. The yield strength monitored by acoustic emission testing increased with the time of healing. The external fixator could be removed safely and successfully in 97% of the patients. Thus, the acoustic emission method has good potential as a reliable method for monitoring the mechanical status of healing bone.

  7. Treatment of open tibial shaft fracture with soft tissue and bone defect caused by aircraft bomb--case report.

    PubMed

    Golubović, Zoran; Vidić, Goran; Trenkić, Srbobran; Vukasinović, Zoran; Lesić, Aleksandar; Stojiljković, Predrag; Stevanović, Goran; Golubović, Ivan; Visnjić, Aleksandar; Najman, Stevo

    2010-01-01

    Aircraft bombs can cause severe orthopaedic injuries. Tibia shaft fractures caused by aircraft bombs are mostly comminuted and followed by bone defects, which makes the healing process extremely difficult and prone to numerous complications. The goal of this paper is to present the method of treatment and the end results of treatment of a serious open tibial fracture with soft and bone tissue defects resulting from aircraft bomb shrapnel wounds. A 26-year-old patient presented with a tibial fracture as the result of a cluster bomb shrapnel wound. He was treated applying the method of external bone fixation done two days after wounding, as well as of early coverage of the lower leg soft tissue defects done on the tenth day after the external fixation of the fracture. The external fixator was removed after five months, whereas the treatment was continued by means of functional plaster cast for another two months. The final functional result was good. Radical wound debridement, external bone fixation of the fracture, and early reconstruction of any soft tissue and bone defects are the main elements of the treatment of serious fractures.

  8. Stress Fractures of Tibia Treated with Ilizarov External Fixator.

    PubMed

    Górski, Radosław; Żarek, Sławomir; Modzelewski, Piotr; Górski, Ryszard; Małdyk, Paweł

    2016-08-30

    Stress fractures are the result of cyclic loading of the bone, which gradually becomes damaged. Most often they are treated by rest or plaster cast and, in rare cases, by internal fixation. There is little published data on initial reposition followed by stabilization with the Ilizarov apparatus in such fractures. Six patients were treated with an external fixator according to the Ilizarov method for a stress fracture of the tibia between 2007 and 2015. Three patients were initially treated conservatively. Due to increasing tibial deformation, they were qualified for surgical treatment with external stabilization. In the other patients, surgery was the first-line treatment. All patients demonstrated risk factors for a stress fracture. After the surgery, they fully loaded the operated limb. No patient developed malunion, nonunion, infection or venous thrombosis. The average time from the first operation to the removal of the external fixator was 19 weeks. Radiographic and clinical outcomes were satisfactory in all patients. 1. The Ilizarov method allows for successful stabilization of stress fractures of the tibia. 2. It may be a good alternative to internal stabilization, especially in patients with multiple comorbidities which affect bone quality and may impair soft tissue healing.

  9. External wire-frame fixation of digital skin grafts: a non-invasive alternative to the K-wire insertion method.

    PubMed

    Huang, Chenyu; Ogawa, Rei; Hyakusoku, Hiko

    2014-08-01

    The current skin graft fixation methods for digits, including the Kirschner wire insertion technique, can be limited by inadequate or excessive fixation and complications such as infection or secondary injuries. Therefore, the external wire-frame fixation method was invented and used for skin grafting of digits. This study aimed to investigate external wire-frame fixation of digital skin grafts as a non-invasive alternative to the K-wire insertion method. In 2005-2012, 15 patients with burn scar contractures on the hand digits received a skin graft that was then fixed with an external wire frame. The intra-operative time needed to make the wire frame, the postoperative time to frame and suture removal, the graft survival rate, the effect of contracture release and the complications were recorded. In all cases, the contracture release was 100%. The complete graft survival rate was 98.6%. Four patients had epithelial necrosis in <5% of the total area. There were no other complications such as pressure ulcer or hypoxia of fingers. External wire-frame fixation is simple, minimally invasive and a custom-made technique for skin grafting of the fingers. It was designed for its potential benefits and the decreased risk it poses to patients with scar contractures on their fingers. It can be implemented in three phases of grafting, does not affect the epiphyseal line or subsequent finger growth and is suitable for children with multi-digit involvement. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  10. [Effectiveness comparison of flexible fixation and rigid fixation in treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis].

    PubMed

    Li, Yuewei; Zhang, Minghui; Li, Xiaorong; Chen, Xiaoyong; Deng, Jianlong

    2017-07-01

    To compare the effectiveness of flexible fixation and rigid fixation in the treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis. A retrospective analysis was made on the clinical data of 50 patients with ankle pronation-external rotation fractures and distal tibiofibular syndesmosis treated between January 2013 and December 2015. Suture-button fixation was used in 23 patients (flexible fixation group) and cortical screw fixation in 27 patients (rigid fixation group). There was no significant difference in age, gender, weight, side, fracture type, and time from trauma to surgery between 2 groups ( P >0.05). The operation time, medial clear space (MCS), tibiofibular clear space (TFCS), tibiofibular overlap (TFO), American Orthopaedic Foot and Ankle Society (AOFAS) score, and Foot and Ankle Disability Index (FADI) score were compared between 2 groups. The operation time was (83.0±9.1) minutes in the flexible fixation group and was (79.6±13.1) minutes in the rigid fixation group, showing no significant difference ( t =1.052, P =0.265). All patients achieved healing of incision by first intention. The patients were followed up 12-20 months (mean, 14 months). The X-ray films showed good healing of fracture in 2 groups. There was no screw fracture, delayed union or nounion. The fracture healing time was (12.1±2.5) months in the flexible fixation group and was (11.3±3.2) months in the rigid fixation group, showing no significant difference between 2 groups ( t =1.024, P =0.192). Reduction loss occurred after removal of screw in 2 cases of the rigid fixation group. At last follow-up, there was no significant difference in MCS, TFCS, TFO, AOFAS score and FADI score between 2 groups ( P >0.05). Suture-button fixation has similar effectiveness to screw fixation in ankle function and imaging findings, and flexible fixation has lower risk of reduction loss of distal tibiofibular syndesmosis than rigid fixation.

  11. A new animal model for bone atrophic nonunion: fixation by external fixator.

    PubMed

    Kaspar, Katharina; Matziolis, Georg; Strube, Patrick; Sentürk, Ufuk; Dormann, Svenja; Bail, Hermann J; Duda, Georg N

    2008-12-01

    A new small animal model of bone atrophic nonunion was established for investigating the process of bone regeneration by performing cauterization of the periosteum, removal of the local bone marrow, and stabilization with external fixation. The model allows the creation of an atrophic nonunion without the need for a critical size defect. Furthermore, it provides reproducible, well-defined mechanical conditions and minimized physical interference of the implant with the biological processes in the healing zone. Eighty adult Sprague-Dawley rats received an osteotomy of the left femur, stabilized with an external fixator. In half of the animals, the periosteum proximal and distal to the osteotomy was destroyed by cauterization and the adjacent bone marrow was removed (nonunion group). At 2 and 8 weeks after surgery, radiological, biomechanical, histological, and histomorphometrical analyses showed a typical physiological healing in the control group, while the nonunion group was characterized by resorption of the bone ends with some callus formation distant to the osteotomy. At both time points, the callus was composed of significantly less bone and significantly more connective tissue (p < 0.001). In addition, the torsional strength of the osteotomized femur was significantly less in the nonunion group than in the control group, which was comparable to that of the intact femur (p < 0.001). In conclusion, the present model allows the induction of an atrophic nonunion without the need of a critical size defect. It is reproducible, provides standardized biomechanical conditions, and allows minimized interaction of the implant with the healing zone.

  12. Radial and tibial fracture repair with external skeletal fixation. Effects of fracture type, reduction, and complications on healing.

    PubMed

    Johnson, A L; Kneller, S K; Weigel, R M

    1989-01-01

    Twenty-eight consecutive fractures of the canine radius and tibia were treated with external skeletal fixation as the primary method of stabilization. The time of fixation removal (T1) and the time to unsupported weight-bearing (T2) were correlated with: (1) bone involved; (2) communication of the fracture with the external environment; (3) severity of the fracture; (4) proximity of the fracture to the nutrient artery; (5) method of reduction; (6) diaphyseal displacement after reduction; and (7) gap between cortical fragments after reduction. The Kruskal-Wallis one-way analysis of variance was used to test the correlation with p less than .05 set as the criterion for significance. The median T1 was 10 weeks and the median T2 was 11 weeks. None of the variables correlated significantly with either of the healing times; however, there was a strong trend toward longer healing times associated with open fractures and shorter healing times associated with closed reduction. Periosteal and endosteal callus uniting the fragments were observed radiographically in comminuted fractures, with primary bone union observed in six fractures in which anatomic reduction was achieved. Complications observed in the treatment of these fractures included: bone lysis around pins (27 fractures), pin track drainage (27 fractures), pin track hemorrhage (1 fracture), periosteal reaction around pins (27 fractures), radiographic signs consistent with osteomyelitis (12 fractures), degenerative joint disease (2 dogs), and nonunion (1 fracture). Valgus or rotational malalignment resulted in 16 malunions of fractures. One external fixation device was replaced and four loose pins were removed before the fractures healed. One dog was treated with antibiotics during the postoperative period because clinical signs of osteomyelitis appeared.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Virtual stress testing of fracture stability in soldiers with severely comminuted tibial fractures.

    PubMed

    Petfield, Joseph L; Hayeck, Garry T; Kopperdahl, David L; Nesti, Leon J; Keaveny, Tony M; Hsu, Joseph R

    2017-04-01

    Virtual stress testing (VST) provides a non-invasive estimate of the strength of a healing bone through a biomechanical analysis of a patient's computed tomography (CT) scan. We asked whether VST could improve management of patients who had a tibia fracture treated with external fixation. In a retrospective case-control study of 65 soldier-patients who had tibia fractures treated with an external fixator, we performed VST utilizing CT scans acquired prior to fixator removal. The strength of the healing bone and the amount of tissue damage after application of an overload were computed for various virtual loading cases. Logistic regression identified computed outcomes with the strongest association to clinical events related to nonunion within 2 months after fixator removal. Clinical events (n = 9) were associated with a low tibial strength for compression loading (p < 0.05, AUC = 0.74) or a low proportion of failed cortical bone tissue for torsional loading (p < 0.005, AUC = 0.84). Using post-hoc thresholds of a compressive strength of four times body-weight and a proportional of failed cortical bone tissue of 5%, the test identified all nine patients who failed clinically (100% sensitivity; 40.9% positive predictive value) and over three fourths of those (43 of 56) who progressed to successful healing (76.8% specificity; 100% negative predictive value). In this study, VST identified all patients who progressed to full, uneventful union after fixator removal; thus, we conclude that this new test has the potential to provide a quantitative, objective means of identifying tibia-fracture patients who can safely resume weight bearing. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:805-811, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  14. Reconstruction of large diaphyseal bone defect by simplified bone transport over nail technique: A 7-case series.

    PubMed

    Ferchaud, F; Rony, L; Ducellier, F; Cronier, P; Steiger, V; Hubert, L

    2017-11-01

    Reconstruction of large diaphyseal bone defect is complex and the complications rate is high. This study aimed to assess a simplified technique of segmental bone transport by monorail external fixator over an intramedullary nail.A prospective study included 7 patients: 2 femoral and 5 tibial defects. Mean age was 31years (range: 16-61years). Mean follow-up was 62 months (range: 46-84months). Defects were post-traumatic, with a mean length of 7.2cm (range: 4 to 9.5cm). For 3 patients, reconstruction followed primary failure. In 4 cases, a covering flap was necessary. Transport used an external fixator guided by an intramedullary nail, at a rate of 1mm per day. One pin was implanted on either side of the distraction zone. The external fixator was removed 1 month after bone contact at the docking site. Mean bone transport time was 11 weeks (range: 7-15 weeks). Mean external fixation time was 5.1months (range: 3.5 to 8months). Full weight-bearing was allowed 5.7months (range: 3.5-13months) after initiation of transport. In one patient, a pin had to be repositioned. In 3 patients, the transported segment re-ascended after external fixatorablation, requiring repeat external fixation and resumption of transport. There was just 1 case of superficial pin infection. Reconstruction quality was considered "excellent" on the Paley-Marr criteria in 6 cases. The present technique provided excellent reconstruction quality in 6 of the 7 cases. External fixation time was shorter and resumption of weight-bearing earlier than with other reconstruction techniques, notably including bone autograft, vascularized bone graft or the induced membrane technique. Nailing facilitated control of limb axis and length. The complications rate was 50%, comparable to other techniques. This study raises the question of systematic internal fixation of the docking site, to avoid any mobilization of the transported segment. The bone quality, axial control and rapidity shown by the present technique make it well-adapted to reconstruction of diaphyseal bone defect. Four-case series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Treatment of open tibial fracture with bone defect caused by high velocity missiles: a case report.

    PubMed

    Golubović, Zoran; Vukajinović, Zoran; Stojiljković, Predrag; Golubović, Ivan; Visnjić, Aleksandar; Radovanović, Zoran; Najman, Stevo

    2013-01-01

    Tibia fracture caused by high velocity missiles is mostly comminuted and followed by bone defect which makes their healing process extremely difficult and prone to numerous complications. A 34-year-old male was wounded at close range by a semi-automatic gun missile. He was wounded in the distal area of the left tibia and suffered a massive defect of the bone and soft tissue. After the primary treatment of the wound, the fracture was stabilized with an external fixator type Mitkovic, with convergent orientation of the pins. The wound in the medial region of the tibia was closed with the secondary stitch, whereas the wound in the lateral area was closed with the skin transplant after Thiersch. Due to massive bone defect in the area of the rifle-missile wound six months after injury, a medical team placed a reconstructive external skeletal fixator type Mitkovic and performed corticotomy in the proximal metaphyseal area of the tibia. By the method of bone transport (distractive osteogenesis), the bone defect of the tibia was replaced. After the fracture healing seven months from the secondary surgery, the fixator was removed and the patient was referred to physical therapy. Surgical treatment of wounds, external fixation, performing necessary debridement, adequate antibiotic treatment and soft and bone tissue reconstruction are essential in achieving good results in patients with the open tibial fracture with bone defect caused by high velocity missiles. Reconstruction of bone defect can be successfully treated by reconstructive external fixator Mitkovic.

  16. Analysis of usage and associated cost of external fixators at an urban level 1 trauma centre.

    PubMed

    Chaus, George W; Dukes, Chase; Hak, David J; Mauffrey, Cyril; Mark Hammerberg, E

    2014-10-01

    To determine the usage, indication, duration, and cost associated with external fixation usage. Additionally, to show the significant cost associated with external fixator use and reinvigorate discussions on external fixator reuse. A retrospective review of a prospectively gathered trauma database was undertaken to identify all patients treated with external fixation frames for pelvic and lower extremity injuries between September 2007 and July 2010. We noted the indications for frame use, and we determined the average duration of external fixation for each indication. The cost of each frame was calculated from implant records. 341 lower extremity and pelvic fractures were treated with external fixation frames during the study period. Of these, 92% were used as temporary external fixation. The average duration of temporary external fixation was 10.5 days. The cost of external fixation frame components was $670,805 per year. The average cost per external fixation frame was $5900. The majority of external fixators are intended as temporary frames, in place for a limited period of time prior to definitive fixation of skeletal injuries. As such, most frames are not intended to withstand physiologic loads, nor are they expected provide a precise maintenance of reduction. Given the considerable expense associated with external fixation frame components, the practice of purchasing external fixation frame components as disposable "single-use" items appears to be somewhat wasteful. Level II. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Novel Use of Active Leptospermum Honey for Ringed Fixator Pin Site Care in Diabetic Charcot Deformity Patients.

    PubMed

    Lazarides, Alexander L; Hamid, Kamran S; Kerzner, Michael S

    2018-04-01

    Open reduction with external fixation (OREF) utilizing fine wire ringed fixators for correction of Charcot deformity has gained popularity over the past decade. Pin site infections are a well-documented complication of external fixation as well as a driver of escalating health care costs. We aimed to demonstrate the safety and efficacy of a novel method of pin site care utilizing active Leptospermum honey-impregnated dressings (MediHoney) in diabetic patients undergoing deformity correction with OREF. Twenty-one diabetic patients with Charcot deformities of the lower extremity were prospectively enrolled and followed for pin site complications following OREF for deformity correction. Active Leptospermum honey dressings were applied at metal-cutaneous interfaces at the end of the OREF procedure and replaced weekly for a total of 8 weeks. Patients were monitored for pin site infections from the time of surgery until external fixator removal. Sixteen consecutive patients receiving standard OREF for Charcot deformities were evaluated retrospectively to serve as a control group. Of the 21 enrolled patients, 19 underwent OREF and followed up throughout the study period. Treated patients had a mean age of 58.5 years and mean body mass index measuring 33.3 kg/m 2 as documented prior to surgery. The 15 patients with hemoglobin A1c labs drawn in the 3 months preceding surgery averaged 7.5. Fixators were removed at an average of 12.1 weeks after adequate bony healing. Of the 244 pin sites in 19 patients, 3 pin sites (1.2% of pins) in 2 patients (10.5% of patients) showed evidence of superficial infection. All infections resolved with oral antibiotics. Infection rates were significantly reduced when compared to the standard care control group. Pilot data in a prospectively collected case series demonstrate safety and efficacy of active Leptospermum honey-impregnated dressings when used for fine wire ringed fixator pin site care in diabetic Charcot deformity patients. Further investigation in the form of a prospective randomized controlled study is warranted to demonstrate the potential value of this novel intervention. Level IV.

  18. The impact of zoledronic acid on regenerate and native bone after consolidation and removal of the external fixator: an animal model study.

    PubMed

    Saghieh, Said; Khoury, Nabil J; Tawil, Ayman; Masrouha, Karim Z; Musallam, Khaled M; Khalaf, Kinda; Dosh, Laura; Jaouhari, Rosemarie Reich; Birjawi, Ghina; El-Hajj-Fuleihan, Ghada

    2010-02-01

    We investigated the role of zoledronic acid on the regenerate and native bone after consolidation and removal of the external fixator in a rabbit model of distraction osteogenesis using 28 New Zealand white rabbits. The rabbits were randomly distributed into two groups. The first group received three doses of zoledronic acid (ZA) 0.1 mg/kg subcutaneously at weekly intervals while the second group received injections of sterile saline. Distraction started on day 7 at a rate of 0.8 mm/day for 12 days. At week 3 the average lengthening, regenerate density, and regenerate continuity were comparable between the two groups. At week 11 the regenerate in the treated group had a significant increase in Bone Mineral Density (BMD) and Bone Mineral Content (BMC) compared to the placebo group. On axial compression, the regenerate showed an increase in the peak load and a higher modulus of elasticity in the treated group. At 6 months, radiographs demonstrated signs of osteopenia of the proximal metaphysis in the control group, and failure of new bone formation around the pin sites in the treated group. BMC and BMD value differences between the two groups were not statistically significant. Histologically, there was persistence of more bone trabeculae in the medullary canal of the regenerate with the persistence of the pin-holes in the treated group. Mechanically, the regenerates in the treated group remain stronger in resisting the axial compression. The proximal fragment in the treated group exhibited a statistically significant decrease in the peak load, toughness and efail %. In conclusion, bisphosphonate-treated rabbits have a stronger regenerate during distraction, and directly after removal of the fixator. They do not develop disuse osteopenia in their lengthened tibia. This treatment may shorten the time in the external fixator and prevent fragility fractures in the treated extremity. However, its long-term safety has not yet been established. (c) 2009 Elsevier Inc. All rights reserved.

  19. Use of hinged transarticular external fixation for adjunctive joint stabilization in dogs and cats: 14 cases (1999-2003).

    PubMed

    Jaeger, Gayle H; Wosar, Marc A; Marcellin-Little, Denis J; Lascelles, B Duncan X

    2005-08-15

    To describe placement of hinged transarticular external fixation (HTEF) frames and evaluate their ability to protect the primary repair of unstable joints while allowing joint mobility in dogs and cats. Retrospective study. 8 cats and 6 dogs. HTEF frames were composed of metal or epoxy connecting rods and a hinge. Measurements of range of motion of affected and contralateral joints and radiographs were made after fixator application and removal. 9 animals (4 cats and 5 dogs) had tarsal and 5 (4 cats and 1 dog) had stifle joint injuries. Treatment duration ranged from 45 to 100 days (median, 57 days). Ranges of motion in affected stifle and tarsal joints were 57% and 72% of control while HTEF was in place and 79% and 84% of control after frame removal. Complications were encountered in 3 cats and 2 dogs and included breakage of pins and connecting rods, hinge loosening, and failure at the hinge-epoxy interface. HTEF in animals with traumatic joint instability provided adjunctive joint stabilization during healing and protection of the primary repair and maintained joint motion during healing, resulting in early weight bearing of the affected limb.

  20. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    PubMed

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  1. An original knee arthrodesis technique combining external fixator with Steinman pins direct fixation.

    PubMed

    Riouallon, G; Molina, V; Mansour, C; Court, C; Nordin, J-Y

    2009-06-01

    Knee arthrodesis may be the last possible option for infected total knee arthroplasty (TKA) patients and in revision cases involving severe bone loss and/or extensor mechanism damages. Success in these situations depends on achieving good fixation assembly stability. We report bone fusion results using a fixation technique combining cross-pinning by two Steinman pins with a single-frame external fixator. Remission of infection at long-term follow-up was an additional criteria assessed for those cases initially treated for sepsis. This fixation modality improves fusion rates. In six of this series of eight patients (mean age: 59 years), surgery was performed in a context of infection: five cases of infected TKA, and one case of septic arthritis. In the other two cases, arthrodesis was respectively indicated for a severe post-traumatic stiffness compounded by extensor system rupture and for a fracture combined to a complete mechanical implant loosening. In three of the six infection cases, arthrodesis was performed as a single-stage procedure. All patients were operated on using the same technique: primary arthrodesis site stabilization by frontal cross-pinning with two Steinman pins, followed by installation of a sagittal external fixator frame. Results were assessed at a mean 8 year follow-up. All the arthrodeses showed fusion at a mean 3.5 months (range: 2.5 to 6 months) postoperative delay without reintervention. Weight-bearing was resumed at 2 to 3 months. The external fixator was removed at a mean 5.2 months. No recurrence of infection was observed over a mean follow-up of 8.2 years (range: 1 to 15 years). Three complications occurred: one hematoma, managed surgically; one supracondylar fracture treated orthopedically; and one osteitis, managed by surgical curettage. This knee arthrodesis technique proved effective, with no failures in this short series, especially in cases of primary infection. It is a reproducible means of osteosynthesis, with little subsequent morbidity. Fixation in two orthogonal planes seemed to provide the stability required to achieve bone fusion. This assembly avoids internal fixation, which is never risk-free in a context of primary sepsis. Level IV. Retrospective study. 2009 Elsevier Masson SAS. All rights reserved.

  2. Management of tibial fractures using a circular external fixator in two calves.

    PubMed

    Aithal, Hari Prasad; Kinjavdekar, Prakash; Amarpal; Pawde, Abhijit Motiram; Singh, Gaj Raj; Setia, Harish Chandra

    2010-07-01

    To report the repair of tibial diaphyseal fractures in 2 calves using a circular external skeletal fixator (CEF). Clinical report. Crossbred calves (n=2; age: 6 months; weight: 55 and 60 kg). Mid-diaphyseal tibial fractures were repaired by the use of a 4-ring CEF (made of aluminum rings with 2 mm K-wires) alone in 1 calf and in combination with hemicerclage wiring in 1 calf. Both calves had good weight bearing with moderate lameness postoperatively. Fracture healing occurred by day 60 in 1 calf and by day 30 in calf 2. The CEF was well maintained and tolerated by both calves through fracture healing. Joint mobility and limb usage improved gradually after CEF removal. CEF provided a stable fixation of tibial fractures and healing within 60 days and functional recovery within 90 days. CEF can be safely and successfully used for the management of selected tibial fractures in calves.

  3. Hybrid Fixation for Ankle Fusion in Diabetic Charcot Arthropathy.

    PubMed

    El-Mowafi, Hani; Abulsaad, Mazen; Kandil, Yasser; El-Hawary, Ahmed; Ali, Samer

    2018-01-01

    Ankle fusion is difficult to achieve in the diabetic Charcot ankle Brodsky type 3a because of the poor quality of the bone and the inability to achieve a stable biomechanical construct. The aim of this study was to report the outcome of ankle fusion using a combination of an intramedullary nail and a circular external fixator in patients with diabetic Charcot arthropathy. We prospectively studied 24 patients with diabetic Charcot arthropathy of the ankle who were treated by fusion of the tibiotalar joint using a combined retrograde intramedullary nail and Ilizarov external fixator. Their mean age was 50.7 ± 6.9 (range, 43-62) years. The mean follow-up after surgery was 36.4 ± 5.8 (range, 24-98) months. Twenty-two patients (92%) achieved clinical and radiographic solid bony fusion. No patients in this series needed amputation. All the patients were pain free, and the mean American Orthopaedic Foot & Ankle Society Score (AOFAS) improved significantly from 34.6 ± 6.8 to 66.4 ± 4.5 at the last follow-up. Two patients developed an ulcer over the heel due to a prominent nail. The ulcer healed after nail removal. Eight patients developed pin tract infection. We report a successful outcomes of ankle fusions using combined intramedullary nail locked only proximally and ring external fixator (hybrid fixation) in patients with diabetic Charcot arthropathy. Level IV, case series.

  4. Blount Disease

    MedlinePlus

    ... involve cutting the tibia, realigning it, and holding it in place with a plate and screws (this is called an osteotomy ); some involve removing the damaged growth plate; and some use a device called an external fixator to hold ... is necessary, it will be done under general anesthesia (you will ...

  5. Trichophyton rubrum osteomyelitis after calcaneus external fixation pin stabilization of a pilon fracture.

    PubMed

    Waryasz, Gregory R; Bariteau, Jason T

    2014-01-01

    Fungal organisms are an uncommon cause of osteomyelitis, and no dermatophyte osteomyelitis infections have been reported in published studies. We present the case of Trichophyton rubrum osteomyelitis of the calcaneus. Our patient initially presented with a pilon fracture requiring temporary external fixation while awaiting definitive fixation. From our review of the published data, the present case is the first of this type of fungal osteomyelitis to be reported. The patient was evaluated for a left neck mass during his hospitalization that was later found to be consistent with salivary duct carcinoma of the tail of the parotid gland. A left neck dissection and superficial excision of the parotid gland was performed after fixation of his pilon fracture. Subsequently, he developed an increasing lucency in the calcaneus and symptoms of pain and erythema months after the calcaneus pin had been removed. The osteomyelitis was treated with surgical debridement and 3 months of itraconazole once cultures had definitively grown T. rubrum. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Distal femoral derotational osteotomy with external fixation for correction of excessive femoral anteversion in patients with cerebral palsy.

    PubMed

    Skiak, Eyad; Karakasli, Ahmet; Basci, Onur; Satoglu, Ismail S; Ertem, Fatih; Havitcioglu, Hasan

    2015-09-01

    Patients with cerebral palsy (CP) disorder often develop rotational hip deformity. Increasing deformities impair already diminished walking abilities; femoral osteotomies are often performed to maintain and improve walking abilities. Fixation of osteotomies with condylar plates has been used successfully, but does not often enable immediate postoperative full weight-bearing. To avoid considerable postoperative rehabilitation deficit and additional bone loss because of inactivity, a postoperative treatment with full weight-bearing, is therefore, desirable. Self-tapping Schanz screws with a unilateral external fixator crossing the knee joint providing stronger anchoring in osteopenic bone might fulfill these demands. A retrospective study was carried out on 27 ambulatory CP patients, mean age 17.5 years (range 9-22 years); 11 patients with bilateral severe intoeing deformities underwent a supracondylar femoral osteotomy between September 2008 and April 2012. All patients were allowed to bear their full weight postoperatively. The aim of this study was to describe the technique, the results of this technique, to evaluate the time required for bone healing, and the type of complications associated with a distal derotational femoral osteotomy fixed with a uniaxial external fixator crossing the knee joint. A total of 27 patients were studied [mean weight 48.8 kg (range 29.8-75 kg)]. The mean preoperative rotation included internal rotation of 69° and external rotation of 17°. All patients were evaluated clinically and radiographically for a minimum of 1 year after surgery. There was a significant decrease in the mean medial rotation from 69° to 32° (P=0.00034). The lateral rotation increased significantly from preoperative 17° to postoperative 45° (P=0.0011). The femoral anteversion decreased significantly from a mean of 55° preoperatively to a mean 17° postoperatively (P=0.030). All patients, except one, achieved solid fusion uneventfully. One patient was a 16-year-old female who had sustained a knee flexion contracture of 30° because of a delay in the physiotherapy program. One 13-year-old female patient with a bilateral osteotomy had a nondisplaced fracture in her right femur after a direct trauma 2 weeks after removal of an external fixator, and was treated by a cast. Another 17-year-old male patient developed a nonunion because of loosening of two pins and achieved solid union after revision by dynamic compression plate plating. Besides four cases with superficial pin-tract infection, no other complications were documented. Minimally invasive supracondylar femoral derotational osteotomy fixed with a unilateral external fixators crossing the knee joint is a reliable procedure in CP patients. Most patients can be treated with early postoperative full weight-bearing. However, removal of the knee joint crossing fixator should be performed as early as possible to achieve a full range of motion.

  7. Clinical results of resection arthrodesis by triangular external fixation for posttraumatic arthrosis of the ankle joint in 89 cases.

    PubMed

    Kiene, J; Schulz, Arndt P; Hillbricht, S; Jürgens, Ch; Paech, A

    2009-01-28

    The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations.

  8. Clinical results of resection arthrodesis by triangular external fixation for posttraumatic arthrosis of the ankle joint in 89 cases

    PubMed Central

    2009-01-01

    The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. Patients and Methods From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Results: Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Conclusion Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations. PMID:19258207

  9. Free flap reconstructions of tibial fractures complicated after internal fixation.

    PubMed

    Nieminen, H; Kuokkanen, H; Tukiainen, E; Asko-Seljavaara, S

    1995-04-01

    The cases of 15 patients are presented where microvascular soft-tissue reconstructions became necessary after internal fixation of tibial fractures. Primarily, seven of the fractures were closed. Eleven fractures had originally been treated by open reduction and internal fixation using plates and screws, and four by intramedullary nailing. All of the patients suffered from postoperative complications leading to exposure of the bone or fixation material. The internal fixation material was removed and radical revision of dead and infected tissue was carried out in all cases. Soft tissue reconstruction was performed using a free microvascular muscle flap (11 latissimus dorsi, three rectus abdominis, and one gracilis). In eight cases the nonunion of the fracture indicated external fixation. The microvascular reconstruction was successful in all 15 patients. In one case the recurrence of deep infection finally indicated a below-knee amputation. In another case, chronic infection with fistulation recurred postoperatively. After a mean follow-up of 26 months the soft tissue coverage was good in all the remaining 13 cases. All the fractures united. Microvascular free muscle flap reconstruction of the leg is regarded as a reliable method for salvaging legs with large soft-tissue defects or defects in the distal leg. If after internal fixation of the tibial fracture the osteosynthesis material or fracture is exposed, reconstruction of the soft-tissue can successfully be performed by free flap transfer. By radical revision, external fixation, bone grafting, and a free flap the healing of the fracture can be achieved.

  10. [Comparison of external fixation with or without limited internal fixation for open knee fractures].

    PubMed

    Li, K N; Lan, H; He, Z Y; Wang, X J; Yuan, J; Zhao, P; Mu, J S

    2018-03-01

    Objective: To explore the characteristics and methods of different fixation methods and prevention of open knee joint fracture. Methods: The data of 86 cases of open knee joint fracture admitted from January 2002 to December 2015 in Department of Orthopaedics, Affiliated Hospital of Chengdu University were analyzed retrospectively.There were 65 males and 21 females aged of 38.6 years. There were 38 cases treated with trans articular external fixation alone, 48 cases were in the trans articular external fixation plus auxiliary limited internal fixation group. All the patients were treated according to the same three stages except for different fixation methods. Observation of external fixation and fracture fixation, fracture healing, wound healing and treatment, treatment and related factors of infection control and knee function recovery. χ(2) test was used to analyze data. Results: Eleven patients had primary wound healing, accounting for 12.8%. Seventy-five patients had two wounds healed, accounting for 87.2%. Only 38 cases of trans articular external fixator group had 31 cases of articular surface reduction, accounting for 81.6%; Five cases of trans articular external fixator assisted limited internal fixation group had 5 cases of poor reduction, accounting for 10.4%; There was significant difference between the two groups (χ(2)=44.132, P <0.05). Take a single cross joint external fixation group, a total of 23 cases of patients with infection, accounted for 60.5% of external fixation group; trans articular external fixation assisted limited internal fixation group there were 30 cases of patients with infection, accounting for the assistance of external fixator and limited internal fixation group 62.5%; There was significant difference between the two groups(χ(2)=0.035, P >0.05). Five cases of fracture nonunion cases of serious infection, patients voluntarily underwent amputation. The Lysholm Knee Scale: In the external fixation group, 23 cases were less than 50 points, accounting for 60.5%, 15 cases were more than 50 points, accounting for 39.5%, external fixation and limited internal fixation group 20 cases were less than 50 points, accounting for 41.7%, 28 cases were more than 50 points, accounting for 58.3%; There was significant difference between the two groups(χ(2)=1.279, P >0.05). Conclusions: Prevention and control of infection is a central link in the treatment of open fracture of the knee. Trans articular external fixator plus limited internal fixation is an important measure to treat open fracture of the knee-joint.

  11. New fixation method for maxillary distraction osteogenesis using locking attachments.

    PubMed

    Suzuki, Eduardo Yugo; Buranastidporn, Boonsiva; Ishii, Masatoshi

    2006-10-01

    The external traction hooks of the intraoral splint used in the rigid external distraction (RED) system for maxillary distraction osteogenesis interfere with the surgical procedures. The purpose of this study is to introduce an innovative splint fixation method for maxillary distraction osteogenesis with Locking Attachments and evaluate their advantages, such as reduction of operating time compared with the traditional intraoral splint method. Retrospective comparison of operative times of maxillary Le Fort I osteotomy procedures was carried out with the traditional protocol using the intraoral splint cemented to the maxillary dentition (n = 14), and a removable intraoral splint that is inserted postsurgically (n = 14). Operative procedure times were compared and analyzed statistically using the data extracted from the surgical records. There were no complications inserting the removable splint postsurgically, including pain, discomfort, or time-consuming procedure. Stable and secure splint fixation was obtained before the distraction procedure and the desired treatment goals were obtained in all patients. The total operative procedure times were significantly reduced in the Locking Attachments group by 24% to 41% (approximately 65 minutes) compared with earlier operations involving the conventional splints (P < .05). Maxillary distraction osteogenesis with the Locking Attachments is a highly effective fixation approach to manage severe hypoplastic maxilla, eliminating lip constraints resulting from scarring and allowing for easier, more deliberate and careful dissection. The use of the Locking Attachments is reliable in craniofacial surgery and has proved to be advantageous in the reduction of the operating time and surgical risks.

  12. Ball-joint versus single monolateral external fixators for definitive treatment of tibial shaft fractures.

    PubMed

    Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J

    2014-07-01

    To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.

  13. Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures

    PubMed Central

    Kopylov, Philippe; Geijer, Mats; Tägil, Magnus

    2009-01-01

    Background and purpose In unstable distal radial fractures that are impossible to reduce or to maintain in reduced position, the treatment of choice is operation. The type of operation and the choice of implant, however, is a matter of discussion. Our aim was to investigate whether open reduction and internal fixation would produce a better result than traditional external fixation. Methods 50 patients with an unstable or comminute distal radius fracture were randomized to either closed reduction and bridging external fixation, or open reduction and internal fixation using the TriMed system. The primary outcome parameter was grip strength, but the patients were followed for 1 year with objective clinical assessment, subjective outcome using DASH, and radiographic examination. Results At 1 year postoperatively, grip strength was 90% (SD 16) of the uninjured side in the internal fixation group and 78% (17) in the external fixation group. Pronation/supination was 150° (15) in the internal fixation group and 136° (20) in the external fixation group at 1 year. There were no differences in DASH scores or in radiographic parameters. 5 patients in the external fixation group were reoperated due to malunion, as compared to 1 in the internal fixation group. 7 other cases were classified as radiographic malunion: 5 in the external fixation group and 2 in the internal fixation group. Interpretation Internal fixation gave better grip strength and a better range of motion at 1 year, and tended to have less malunions than external fixation. No difference could be found regarding subjective outcome. PMID:19857180

  14. Biomechanical Comparison of External Fixation and Compression Screws for Transverse Tarsal Joint Arthrodesis.

    PubMed

    Latt, L Daniel; Glisson, Richard R; Adams, Samuel B; Schuh, Reinhard; Narron, John A; Easley, Mark E

    2015-10-01

    Transverse tarsal joint arthrodesis is commonly performed in the operative treatment of hindfoot arthritis and acquired flatfoot deformity. While fixation is typically achieved using screws, failure to obtain and maintain joint compression sometimes occurs, potentially leading to nonunion. External fixation is an alternate method of achieving arthrodesis site compression and has the advantage of allowing postoperative compression adjustment when necessary. However, its performance relative to standard screw fixation has not been quantified in this application. We hypothesized that external fixation could provide transverse tarsal joint compression exceeding that possible with screw fixation. Transverse tarsal joint fixation was performed sequentially, first with a circular external fixator and then with compression screws, on 9 fresh-frozen cadaveric legs. The external fixator was attached in abutting rings fixed to the tibia and the hindfoot and a third anterior ring parallel to the hindfoot ring using transverse wires and half-pins in the tibial diaphysis, calcaneus, and metatarsals. Screw fixation comprised two 4.3 mm headless compression screws traversing the talonavicular joint and 1 across the calcaneocuboid joint. Compressive forces generated during incremental fixator foot ring displacement to 20 mm and incremental screw tightening were measured using a custom-fabricated instrumented miniature external fixator spanning the transverse tarsal joint. The maximum compressive force generated by the external fixator averaged 186% of that produced by the screws (range, 104%-391%). Fixator compression surpassed that obtainable with screws at 12 mm of ring displacement and decreased when the tibial ring was detached. No correlation was found between bone density and the compressive force achievable by either fusion method. The compression across the transverse tarsal joint that can be obtained with a circular external fixator including a tibial ring exceeds that which can be obtained with 3 headless compression screws. Screw and external fixator performance did not correlate with bone mineral density. This study supports the use of external fixation as an alternative method of generating compression to help stimulate fusion across the transverse tarsal joints. The findings provide biomechanical evidence to support the use of external fixation as a viable option in transverse tarsal joint fusion cases in which screw fixation has failed or is anticipated to be inadequate due to suboptimal bone quality. © The Author(s) 2015.

  15. Medial submuscular plating of the femur in a series of paediatric patients: a useful alternative to standard lateral techniques.

    PubMed

    Nayagam, S; Davis, B; Thevendran, G; Roche, A J

    2014-01-01

    We describe the technique and results of medial submuscular plating of the femur in paediatric patients and discuss its indications and limitations. Specifically, the technique is used as part of a plate-after-lengthening strategy, where the period of external fixation is reduced and the plate introduced by avoiding direct contact with the lateral entry wounds of the external fixator pins. The technique emphasises that vastus medialis is interposed between the plate and the vascular structures. A total of 16 patients (11 male and five female, mean age 9.6 years (5 to 17)), had medial submuscular plating of the femur. All underwent distraction osteogenesis of the femur with a mean lengthening of 4.99 cm (3.2 to 12) prior to plating. All patients achieved consolidation of the regenerate without deformity. The mean follow-up was 10.5 months (7 to 15) after plating for those with plates still in situ, and 16.3 months (1 to 39) for those who subsequently had their plates removed. None developed a deep infection. In two patients a proximal screw fractured without loss of alignment; one patient sustained a traumatic fracture six months after removal of the plate. Placing the plate on the medial side is advantageous when the external fixator is present on the lateral side, and is biomechanically optimal in the presence of a femoral defect. We conclude that medial femoral submuscular plating is a useful technique for specific indications and can be performed safely with a prior understanding of the regional anatomy.

  16. Comparison of effects of seven treatment methods for distal radius fracture on minimizing complex regional pain syndrome

    PubMed Central

    Sun, Tao

    2016-01-01

    Introduction Using network meta-analysis, we evaluated the adverse effects of the seven most common treatment methods, i.e., bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating, by their associated risk of developing complex regional pain syndrome (CRPS) in distal radius fracture (DRF) patients. Material and methods Following an exhaustive search of scientific literature databases for high quality studies, randomized controlled trials (RCTs) related to our study topic were screened and selected based on stringent predefined inclusion and exclusion criteria. Data extracted from the selected studies were used for statistical analyses using Stata 12.0 software. Results A total of 17 RCTs, including 1658 DRF patients, were enrolled in this network meta-analysis. Among the 1658 DRF patients, 452 received bridging external fixation, 525 received non-bridging external fixation, 154 received K-wire fixation, 84 received plaster fixation, 132 received dorsal plating, 123 received volar plating, and 188 received dorsal and volar plating. When compared to bridging external fixation patients, there was no marked difference in the CRPS risk in DRF patients receiving different treatments (all p > 0.05). However, the surface under the cumulative ranking curves (SUCRA) for plaster fixation (77.0%) and non-bridging external fixation (71.3%) were significantly higher compared with the other five methods. Conclusions Our findings suggest that compared with bridging external fixation, K-wire fixation, dorsal plating, volar plating, dorsal and volar plating, plaster fixation and non-bridging external fixation might be the better treatment methods to reduce the risk of CRPS in DRF patients. PMID:28144268

  17. [Treatment of bacterial infection in the interphalangeal joints of the hand].

    PubMed

    Vorderwinkler, K-P; Mühldorfer, M; Pillukat, T; van Schoonhoven, J

    2011-07-01

    Radical debridement of joint infection, prevention of further infection-related tissue destruction. Septic arthritis of interphalangeal joints in the thumb and fingers. Extensive soft tissue defects. Severe impairment of blood circulation, finger gangrene. Noncompliance for immobilization or for treatment with external fixator. Arthrotomy and irrigation with isotonic solution. Radical tissue debridement. Joint preservation possible only in the absence of infection-related macroscopic cartilage damage. Otherwise, resection of the articular surfaces and secondary arthrodesis. Insertion of antibiotic-coated devices. Temporary immobilization with external fixator. Inpatient postoperative treatment with 5-day intravenous administration of a second-generation cephalosporine (e.g., Cefuroxim®) followed by 7-10 days oral application. Adaptation of antibiotics according to antibiogram results. In joint-preserving procedures, radiographs and fixator removal after 4 weeks, active joint mobilization. If joint surfaces were resected, removal of fixator after 6 weeks; arthrodesis under 3-day intravenous broad-band antibiotic prophylaxis. Splint immobilization until consolidation (6-8 weeks). In 10 of 40 patients, the infected joint could be preserved. All infections healed. After an average duration of therapy of 6 (3-11) weeks, 4 individuals were free of complaints, and 6 patients had minor symptoms. Overall range of motion in the affected finger was reduced by 25-50° in 5 patients. All patients could return to work after 6.6 (4-11) weeks. A total of 30 patients were treated with joint resection and external fixator. After 5.6 (4-8) weeks, arthrodesis was performed, leading to consolidation in 29 patients. One patient underwent amputation after 4 months due to delayed gangrene. Treatment duration was 15.7 (7-25) weeks. Eight patients reported no complaints, 14 suffered mild symptoms, 5 had moderate, and 3 had severe symptoms in daily life. In 15 cases, range of motion was diminished by 10-80° in the remaining joints of the affected finger. Patients could return to work after 16.2 (6-28) weeks.

  18. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    PubMed

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P <0.05). There were no statistically significant differences observed between two approaches with respect to nounion, re-operation, complex regional pain syndrome, carpal tunnel syndrome, neurapraxia, tendonitis, painful hardware, scar( P >0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  19. [Analysis of the results of bone healing in femurs lengthened by the gradual distraction method in children and adolescents].

    PubMed

    Jochymek, J; Skvaril, J; Ondrus, S

    2009-10-01

    Treatment of leg length inequality via lengthening of the shorter extremity is an infrequent orthopedic procedure due to the requirement of special distraction devices and possible serious complications. Essential qualitative changes in operative technique development are associated with the name of G. A. Ilizarov, who paved the way for the autoregenerate gradual distraction method in the 1950s. In the years 1990 through 2007 a total of 67 patients underwent femur lengthening via gradual distraction using various types of external fixators at the Department of Pediatric Surgery, Orthopedics, and Traumatology, Faculty Hospital in Brno. The quality of bone healing was monitored and a number of parameters followed and statistically evaluated using regularly scheduled X-ray examinations. In 13 cases we had to remove the external fixator following the distraction phase, perform an osteosynthesis via a splint and fill the distraction gap via spongioplasty. The bone healing was satisfactory in the remaining 54 patients and the lengthened bone required no other fixation method. The analysis showed statistically significant deceleration in bone healing following distraction in female patients over 12 years of age, and in boys over 14 years of age. Lack of periosteal callus five weeks after surgery always signified serious problems in further healing. Severe complications were recorded in 11 cases during the distraction phase, and in 12 cases after the removal of the distraction apparatus. Our results fully correspond with the data and experience of others cited authors. In addition our study showed deceleration in bone healing in girls over 12 years and in boys over 14 years of age and serious problem in healing when is lack of periostal callus five weeks after surgery. The aim of this report was to present the results of our study of distraction gap bone healing using the gradual lengthening approach. Key words: leg lengthening, gradual distraction, external fixation, leg discrepancy, complication.

  20. Comparison of Monolateral External Fixation and Internal Fixation for Skeletal Stabilisation in the Management of Small Tibial Bone Defects following Successful Treatment of Chronic Osteomyelitis.

    PubMed

    Wang, Yicun; Jiang, Hui; Deng, Zhantao; Jin, Jiewen; Meng, Jia; Wang, Jun; Zhao, Jianning; Sun, Guojing; Qian, Hongbo

    2017-01-01

    To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled.

  1. Comparison of Monolateral External Fixation and Internal Fixation for Skeletal Stabilisation in the Management of Small Tibial Bone Defects following Successful Treatment of Chronic Osteomyelitis

    PubMed Central

    Wang, Yicun; Jiang, Hui; Deng, Zhantao; Meng, Jia; Wang, Jun

    2017-01-01

    Background To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. Methods 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Results Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. Conclusions It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled. PMID:29333448

  2. Distal tibial pilon fractures (AO/OTA type B, and C) treated with the external skeletal and minimal internal fixation method.

    PubMed

    Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan

    2013-09-01

    Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In fractures types B and C dynamic external skeletal fixation allows early mobility in the ankle joint.

  3. A Prospective Randomized Trial to Assess Fixation Strategies for Severe Open Tibia Fractures: Modern Ring External Fixators Versus Internal Fixation (FIXIT Study).

    PubMed

    OʼToole, Robert V; Gary, Joshua L; Reider, Lisa; Bosse, Michael J; Gordon, Wade T; Hutson, James; Quinnan, Stephen M; Castillo, Renan C; Scharfstein, Daniel O; MacKenzie, Ellen J

    2017-04-01

    The treatment of high-energy open tibia fractures is challenging in both the military and civilian environments. Treatment with modern ring external fixation may reduce complications common in these patients. However, no study has rigorously compared outcomes of modern ring external fixation with commonly used internal fixation approaches. The FIXIT study is a prospective, multicenter randomized trial comparing 1-year outcomes after treatment of severe open tibial shaft fractures with modern external ring fixation versus internal fixation among men and women of ages 18-64. The primary outcome is rehospitalization for major limb complications. Secondary outcomes include infection, fracture healing, limb function, and patient-reported outcomes including physical function and pain. One-year treatment costs and patient satisfaction will be compared between the 2 groups, and the percentage of Gustilo IIIB fractures that can be salvaged without soft tissue flap among patients receiving external fixation will be estimated.

  4. Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.

    PubMed

    Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F

    2015-03-31

    This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P < 0.05); however, there were no significant differences in radial-ulnar deviation, wrist range of motion, or wrist function score between groups (P > 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.

  5. An in Vivo Experimental Comparison of Stainless Steel and Titanium Schanz Screws for External Fixation.

    PubMed

    Ganser, Antonia; Thompson, Rosemary E; Tami, Ivan; Neuhoff, Dirk; Steiner, Adrian; Ito, Keita

    2007-02-01

    To compare the clinical benefits of stainless steel (SS) to titanium (Ti) on reducing pin track irritation/infection and pin loosening during external fracture fixation. A tibial gap osteotomy was created in 17 sheep and stabilized with four Schanz screws of either SS or Ti and an external fixation frame. Over the 12 week observation period, pin loosening was assessed by grading the radiolucency around the pins and measuring the extraction torque on pin removal at sacrifice. Irritation/infection was assessed with weekly clinical pin track grading. A histological analysis of the tissue adjacent to the pin site was made to assess biocompatibility. A statistically non-significant trend for less bone resorption around Ti pins was found during the early observation period. However, at sacrifice, there was no difference between the two materials. Also, there was no difference in the extraction torque, and there was similar remodeling and apposition of the bone around the pins. A statistically non-significant trend for more infection about SS pins at sacrifice was found. Histology showed a slightly higher prevalence of reactionary cells in SS samples, but was otherwise not much different than around Ti pins. There is no clinically relevant substantial advantage in using either SS or Ti pins on reducing pin loosening or pin track irritation/infection.

  6. Hybrid External Fixation for Arbeitsgemeinschaft für Osteosynthesefragen (AO) 43-C Tibial Plafond Fractures.

    PubMed

    Abd-Almageed, Emad; Marwan, Yousef; Esmaeel, Ali; Mallur, Amarnath; El-Alfy, Barakat

    2015-01-01

    Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 43-C tibial plafond/pilon fractures represent a challenge for the treating orthopedic surgeon. We assessed the outcomes of using hybrid external fixation for this fracture type. The present prospective cohort study was started in August 2009 and ended by July 2012. Thirty consecutive patients (mean age 37.4 ± 10.7 years) with a type C tibial plafond fracture who had presented to our tertiary care orthopedic hospital were included. Motor vehicle accidents and fall from height were the cause of the fracture in 14 (46.7%) and 13 (43.3%) patients, respectively. A type C3 fracture was present in 25 patients (83.3%), and type C1 and C2 fractures were present in 2 (6.7%) and 3 (10.0%) patients, respectively. Nine fractures (30.0%) were open. Hybrid external fixation was used for all fractures. All fractures were united; clinical healing was achieved by a mean of 18.1 ± 2.2 weeks postoperatively and radiologic healing at a mean of 18.9 ± 1.9 weeks. The fixator was removed at a mean of 20.4 ± 2.0 weeks postoperatively. At a mean follow-up point of 13.4 ± 2.6 months, the mean modified Mazur ankle score was 84.6 ± 10.4. It was not associated with wound classification (p = .256). The most commonly seen complication was ankle osteoarthritis (17 patients; 56.7%); however, it was mild in >50.0% of the affected patients. In conclusion, using hybrid external fixation for type C tibial plafond fractures resulted in good outcomes. However, this should be investigated further in studies with a higher level of evidence. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Correction of a Hyperextension Deformity at the Metacarpophalangeal Joint by Arthroplasty for Osteoarthritis of the Thumb Carpometacarpal Joint Followed by External Fixator: A Case Series: Modified Ilizarov Method for Correction of a Collapsed Thumb Deformity Due to Carpometacarpal Osteoarthritis.

    PubMed

    Hamada, Yoshitaka; Kobayashi, Anna; Sairyo, Koichi; Sato, Ryosuke; Hibino, Naohito

    2015-06-01

    A hyperextension deformity in the advanced stages of carpometacarpal (CMC) arthritis of the thumb could affect the outcomes of thumb CMC joint arthroplasty. We introduce the interesting approach for treating severely collapsed thumb deformities with gradual distraction and coordinated correction of the MCP and CMC joints by means of external fixators. We divided 8 cases into 3 groups according to the angle of passive flexion of the hyperextended MCP joint: group 1, 10-20°, group 2a, 20-40°, and group 2b, >40°, retrospectively. We first performed CMC arthroplasty with trapezium excision. In group 1, we corrected the MCP hyperextension deformity by manual passive flexion and fixed the joint with an extension block Kirshner wire (K-wire) for 2 months. However, deformities recurred in 2 of 5 cases after removing the K-wire. These patients received corrective percutaneous osteotomy with external fixators at the metacarpal neck. In groups 2a and 2b, we performed CMC arthroplasty and set external fixators at the same time. All cases in groups 1 and 2a have been without recurrence for more than 2 years, while a deformity recurred in group 2b. The results of this small case series encouraged us to propose an interesting approach for collapsed zigzag thumb deformity. Good outcomes with excellent maintenance of active MCP movement and no recurrence are highly anticipated if the hyperextended thumb has no obvious degenerative changes and can be corrected by <40° of passive flexion. Our results also indicate a risk of recurrence associated with extension block by K-wire.

  8. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation

    PubMed Central

    Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750

  9. Minimally invasive surgical technique: Percutaneous external fixation combined with titanium elastic nails for selective treatment of tibial fractures.

    PubMed

    Tu, Kai-Kai; Zhou, Xian-Ting; Tao, Zhou-Shan; Chen, Wei-Kai; Huang, Zheng-Liang; Sun, Tao; Zhou, Qiang; Yang, Lei

    2015-12-01

    Several techniques have been described to treat tibial fractures, which respectively remains defects. This article presents a novel intra- and extramedullary fixation technique: percutaneous external fixator combined with titanium elastic nails (EF-TENs system). The purpose of this study is to introduce this new minimally invasive surgical technique and selective treatment of tibial fractures, particularly in segmental fractures, diaphysis fractures accompanied with distal or proximal bone subfissure, or fractures with poor soft-tissue problems. Following ethical approval, thirty-two patients with tibial fractures were treated by the EF-TENs system between January 2010 and December 2012. The follow-up studies included clinical and radiographic examinations. All relevant outcomes were recorded during follow-up. All thirty-two patients were achieved follow-ups. According to the AO classification, 3 Type A, 9 Type B and 20 Type C fractures were included respectively. According to the Anderson-Gustilo classification, there were 5 Type Grade II, 3 Type Grade IIIA and 2 Type Grade IIIB. Among 32 patients, 8 of them were segmental fractures. 12 fractures accompanied with bone subfissure. Results showed no nonunion case, with an average time of 23.7 weeks (range, 14-32 weeks). Among them, there were 3/32 delayed union patients and 0/32 malunion case. 4/32 patients developed a pin track infection and no patient suffered deep infection. The external fixator was removed with a mean time of 16.7 weeks (range, 10-26 weeks). Moreover, only 1/32 patient suffered with the restricted ROM of ankle, none with the restricted ROM of knee. This preliminary study indicated that the EF-TENs system, as a novel intra- and extramedullary fixation technique, had substantial effects on selective treatment of tibial fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. In vivo impact testing on a lengthened femur with external fixation: a future option for the non-invasive monitoring of fracture healing?

    PubMed

    Mattei, Lorenza; Di Puccio, Francesca; Marchetti, Stefano

    2018-05-01

    Non-invasive methods for assessing fracture healing are crucial for biomedical engineers. An approach based on mechanical vibrations was tried out in the 1990s, but was soon abandoned due to insufficiently advanced technologies. The same approach is re-proposed in the present study in order to monitor the healing process of a lengthened femur with an external fixator. The pins screwed into the bone were exploited for the impact testing (IT) to excite the bone and capture its response. Transmission through the soft tissues was thus prevented, and the quality of the signals was improved. Impact tests were performed every three to four weeks for five months. Unfortunately, after seven weeks, some pins were removed due to infection, and thus, the system was modified. Two different configurations were considered: before and after pin removal. An additional configuration was examined in the last two sessions, when the fixator body was removed, while four pins were left in the femur. The evolution of the frequency response function and of the resonant frequencies of the system were analysed for the duration of the monitoring period. The IT results were compared to the indications provided by X-ray images. During the evolution of the callus from the soft phase to the woven bone, the resonant frequencies of the system were found to increase by approximately 2-3% per week. The largest increase (approx. 22%) was observed for the first resonant frequency. After formation of the woven bone, the vibratory response remained almost the same, suggesting that the healing assessment could be related to the relative variation in the resonant frequencies. The results presented support the application of the IT approach for fracture healing assessment. © 2018 The Author(s).

  11. The comparative risk of developing postoperative complications in patients with distal radius fractures following different treatment modalities

    PubMed Central

    Qiu, Wen-Jun; Li, Yi-Fan; Ji, Yun-Han; Xu, Wei; Zhu, Xiao-Dong; Tang, Xian-Zhong; Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei

    2015-01-01

    In this study, we performed a network meta-analysis to compare the outcomes of seven most common surgical procedures to fix DRF, including bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating. Published studies were retrieved through PubMed, Embase and Cochrane Library databases. The database search terms used were the following keywords and MeSH terms: DRF, bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating. The network meta-analysis was performed to rank the probabilities of postoperative complication risks for the seven surgical modalities in DRF patients. This network meta-analysis included data obtained from a total of 19 RCTs. Our results revealed that compared to DRF patients treated with bridging external fixation, marked differences in pin-track infection (PTI) rate were found in patients treated with plaster fixation, volar plating, and dorsal and volar plating. Cluster analysis showed that plaster fixation is associated with the lowest probability of postoperative complication in DRF patients. Plaster fixation is associated with the lowest risk for postoperative complications in DRF patients, when compared to six other common DRF surgical methods examined. PMID:26549312

  12. Intramedullary nailing in the treatment of aseptic tibial nonunion.

    PubMed

    Megas, P; Panagiotopoulos, E; Skriviliotakis, S; Lambiris, E

    2001-04-01

    Fifty patients suffering from aseptic tibial nonunion underwent reamed intramedullary nailing (I.N.) and were retrospectively reviewed. Thirty-six patients were initially treated with external fixation, six with plate and screws, one with a static I.N., and seven with plaster of Paris. Eighteen of the fractures were initially open (A: 5, B: 6, and C: 7 according to the Gustilo classification). In 34 cases a closed procedure was performed, whereas in sixteen, an opening at the nonunion site was unavoidable either to remove metalwork or realign the fragments. Following failed external fixation, secondary I.N. was performed at least 10 days after removal of the device. Bone grafts from the iliac crest were used in three cases, and a fibular osteotomy was performed in 33. Patients were followed up for an average of 2.5 years after nailing, ranging from 10 months to 7 years. A solid union was achieved in all patients within a period of 6 months. One patient developed late infection, which settled after nail removal and one patient developed impending compartment syndrome which was detected on the first post-operative day and was treated with a fasciotomy. Transient peroneal nerve palsy occurred in one patient and this recovered in 3 months, whereas in nine patients a clinically acceptable deformity was noticed. In conclusion, we believe that reamed intramedullary nailing is a highly effective treatment for aseptic tibial nonunions. Early and late complications are rare and bone graft is rarely needed. The method allows early weight bearing even before solid union occurs, short hospitalisation time and early return to work without external support.

  13. In vitro evaluation of the torsional strength reduction of neonate calf metatarsal bones with Bicortical defects resulting from the removal of external fixation implants.

    PubMed

    Brianza, Stefano; Vogel, Susan; Rothstock, Stephan; Desrochers, Andrè; Boure, Ludovic

    2013-01-01

    To compare the torsional strength of calf metatarsal bones with defects produced by removal of 2 different implants. In vitro mechanical comparison of paired bones with bicortical defects resulting from the implantation of 2 different external fixation systems: the transfixation pin (TP) and the pin sleeve system (PS). Neonatal calf metatarsal bones (n = 6 pairs). From each pair, 1 bone was surgically instrumented with 2 PS implants and the contralateral bone with 2 TP implants. Implants were removed immediately leaving bicortical defects at identical locations between paired metatarsi. Each bone was tested in torque until failure. The mechanical variables statistically compared were the torsional stiffness, the torque and angle at failure, and work to failure. For TP and PS constructs, respectively, there were no significant differences between construct types for any of the variables tested. Mean ± SD torsional stiffness: 5.50 ± 2.68 and 5.35 ± 1.79 (Nm/°), P = .75; torque: 57.42 ± 14.84 and 53.43 ± 10.16 (Nm); P = .34; angle at failure: 14.76 ± 4.33 and 15.45 ± 4.84 (°), P = .69; and work to failure 7.45 ± 3.19 and 8.89 ± 3.79 (J), P = .17). Bicortical defects resulting from the removal of PS and TP implants equally affect the investigated mechanical properties of neonate calf metatarsal bones. © Copyright 2012 by The American College of Veterinary Surgeons.

  14. Circular External Fixation as a Primary or Adjunctive Therapy for the Podoplastic Approach of the Diabetic Charcot Foot.

    PubMed

    Short, Daniel J; Zgonis, Thomas

    2017-01-01

    Numerous techniques have been described for surgical management of the diabetic Charcot foot. External fixation has become a main surgical tool for the reconstructive foot and ankle surgeon when dealing with the ulcerated diabetic Charcot foot. In the presence of an open wound and/or osteomyelitis, staged reconstruction with circular external fixation becomes ideal for salvage of the diabetic lower extremity. Also, circular external fixation can provide simultaneous compression and stabilization, correct the underlying osseous or soft tissue deformities, and surgically offload the diabetic Charcot foot. This article describes a variety of circular external fixation applications for the diabetic Charcot foot. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Ankle Distraction Arthroplasty: Indications, Technique, and Outcomes.

    PubMed

    Bernstein, Mitchell; Reidler, Jay; Fragomen, Austin; Rozbruch, S Robert

    2017-02-01

    Ankle distraction is an alternative to ankle arthrodesis or total ankle arthroplasty in younger patients with arthritis. Ankle distraction involves the use of external fixation to mechanically unload the ankle joint, which allows for stable, congruent range of motion in the setting of decreased mechanical loading, potentially promoting cartilage repair. Adjunct surgical procedures are frequently done to address lower-extremity malalignment, ankle equinus contractures, and impinging tibiotalar osteophytes. Patients can bear full weight during the treatment course. The distraction frame frequently uses a hinge, and patients are encouraged to do daily range-of-motion exercises. Although the initial goal of the procedure is to delay arthrodesis, many patients achieve lasting clinical benefits, obviating the need for total ankle arthroplasty or fusion. Complications associated with external fixation are common, and patients should be counseled that clinical improvements occur slowly and often are not achieved until at least 1 year after frame removal.

  16. Evaluation of bone healing in femurs lengthened via the gradual distraction method.

    PubMed

    Jochymek, Jiri; Gal, Petr

    2007-06-01

    Treatment of leg length inequality via lengthening of the shorter extremity is an infrequent orthopedic procedure due to the requirement of special distraction devices and possible serious complications. Essential qualitative changes in operative technique development are associated with the name of G. A. Ilizarov, who paved the way for the autoregenerate gradual distraction method in the 1950s. In the years 1990 through 2006 a total of 57 patients underwent femur lengthening via gradual distraction using various types of external fixators at the Department of Pediatric Surgery, Orthopedics, and Traumatology, Faculty Hospital in Brno. The quality of bone healing was monitored and a number of parameters followed and statistically evaluated using regularly scheduled X-ray examinations. In 11 cases we had to remove the external fixator following the distraction phase, perform an osteosynthesis via a splint and fill the distraction gap via spongioplasty. The bone healing was satisfactory in the remaining 46 patients and the lengthened bone required no other fixation method. The analysis showed statistically significant deceleration in bone healing following distraction in female patients over 12 years of age, and in boys over 14 years of age. Lack of periosteal callus five weeks after surgery always signified serious problems in further healing. Severe complications were recorded in 11 cases during the distraction phase, and in 9 cases after the removal of the distraction apparatus. The aim of this report was to present the results of our study of distraction gap bone healing using the gradual lengthening approach.

  17. Avascular Necrosis of Acetabulum: The Hidden Culprit of Resistant Deep Wound Infection and Failed Fixation of Fracture Acetabulum - A Case Report.

    PubMed

    K, Kandhari V; M, Desai M; S, Bava S; N, Wade R

    2015-01-01

    Chances of avascular necrosis of acetabulum are rare as it enjoys a rich blood supply. But cases of post - traumatic avascular necrosis of acetabulum following fracture of posterior column have been well documented. Importance of identifying and suspecting the avascular necrosis of acetabulum is essential in cases of failed fixation of fracture acetabulum, previously operated using extensile approach to acetabulum; either extended anterior ilio - femoral or tri - radiate approach. Such patients usually present with repeated deep bone infection or with early failure of fixation with aseptic loosening and migration of its components. We present a similar case. 40 years female presented with inadequately managed transverse fracture of left acetabulum done by anterior extended ilio-inguinal approach. The fixation failed. She presented 6 months later with painful hip. Cemented total hip replacement was performed with reconstruction of acetabulum by posterior column plating. Six months postoperatively patient presented with dislodgement of cup, pelvic discontinuity and sinus in the thigh. Two stage revision surgery was planned. First implant, removal; debridement and antibiotic spacer surgery was performed. At second stage of revision total hip replacement, patient had Paprosky grade IIIb defect in acetabulum. Spacer was removed through the posterior approach. Anterior approach was taken for anterior plating. Intra-operatively external iliac pulsations were found to be absent so procedure was abandoned after expert opinion. Postoperatively digital subtraction angiography demonstrated a chronic block in the external iliac artery and corona mortis was the only patent vascular channel providing vascular to the left lower limb. Thus, peripheral limb was stealing blood supply from the acetabulum to maintain perfusion. Patient was ultimately left with pelvic discontinuity, excision arthroplasty and pseudoarthrosis of the left hip. Avascular necrosis of acetabulum is a rare entity & often not recognized. One should be suspicious about diagnosis of avascular necrosis of acetabulum in select cases of failed acetabular fixation, previously operated via extensile anterior ilio - inguinal approach. Angiographic evaluation is essential in revision cases of failed acetabular fixation. Corona mortis (crown or circle of death) can sometimes act as a savior of limb.

  18. Comparison of stability of different types of external fixation.

    PubMed

    Grubor, Predrag; Grubor, Milan; Asotic, Mithat

    2011-01-01

    Stabilization of fractures by external fixator is based on the mechanical connecting of the pins, screwed into the proximal and distal bone fragment. Site of fracture is left without any foreign materials, which is essential for prevention of infections. Aim of this work is to compare stability of constructs bone model-external fixators of different types (Ortofix, Mitković, Charneley and Ilizarov). Stability is estimated under compression and bending (vertical and horizontal forces of 100 kg magnitudes, with distances between pins of4 cm). The mathematical-computer software (Tower, Planet and Planet Pro) was used in the laboratory for accurate measurements of MDP "Jelsingrad" company, Banjaluka. Interfragmental motions in millimeters at the appliance of vertical and horizontal forces were 2.80/2.56 at Ortofix (uniplanar fixator), 1.57/1.56 and fixator by Mitković-M20 (uniplanar fixator with convergent oriented pins), 0.16/0.28 at Charnely's external fixator (biplanar fixator), and 4.49/0.114 mm at Ilizarov's external fixator (fixator with two proximal and two distal rings, each attached on the 6 Kirschner wires). It has confirmed that uniplanar fixation is easier and provides sufficient biomechanics circumstances in the site of fracture for bone healing, especially if the pins are oriented convergently. Ilizarov's fixator is multiplanar fixator, but its stability is dependent of tightness of wires, and provides adequate stability only in transversal plane. By other words, each fixator has its indications; selection of the fixator should be based on theirs mechanic characteristics, fracture geometry, and potential of bone healing, with permanent simplification of treatment, which has to be safe and acceptable for the patient. The main advantage of this study is Sits nature-the comparison of four most used external fixators, by the only one possible way-on the bone model. Each other way of comparison would result with much more questions than answers, due to unacceptable high bias of other parameters, which significantly influences on the results of the study.

  19. Antimicrobial efficacy of external fixator pins coated with a lipid stabilized hydroxyapatite/chlorhexidine complex to prevent pin tract infection in a goat model.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dejong, E. Schuyler; Deberardino, T. M.; Brooks, D. E.

    Background: Pin tract infection is a common complication of external fixation. An antiinfective external fixator pin might help to reduce the incidence of pin tract infection and improve pin fixation. Methods: Stainless steel and titanium external fixator pins, with and without a lipid stabilized hydroxyapatite/chlorhexidine coating, were evaluated in a goat model. Two pins contaminated with an identifiable Staphylococcus aureus strain were inserted into each tibia of 12 goats. The pin sites were examined daily. On day 14, the animals were killed, and the pin tips cultured. Insertion and extraction torques were measured. Results: Infection developed in 100% of uncoatedmore » pins, whereas coated pins demonstrated 4.2% infected, 12.5% colonized, and the remainder, 83.3%, had no growth (p < 0.01). Pin coating decreased the percent loss of fixation torque over uncoated pins (p = 0.04). Conclusion: These results demonstrate that the lipid stabilized hydroxyapatite/chlorhexidine coating was successful in decreasing infection and improving fixation of external fixator pins.« less

  20. Computational modelling of ovine critical-sized tibial defects with implanted scaffolds and prediction of the safety of fixator removal.

    PubMed

    Doyle, Heather; Lohfeld, Stefan; Dürselen, Lutz; McHugh, Peter

    2015-04-01

    Computational model geometries of tibial defects with two types of implanted tissue engineering scaffolds, β-tricalcium phosphate (β-TCP) and poly-ε-caprolactone (PCL)/β-TCP, are constructed from µ-CT scan images of the real in vivo defects. Simulations of each defect under four-point bending and under simulated in vivo axial compressive loading are performed. The mechanical stability of each defect is analysed using stress distribution analysis. The results of this analysis highlights the influence of callus volume, and both scaffold volume and stiffness, on the load-bearing abilities of these defects. Clinically-used image-based methods to predict the safety of removing external fixation are evaluated for each defect. Comparison of these measures with the results of computational analyses indicates that care must be taken in the interpretation of these measures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator

    PubMed Central

    Kim, Hayoung; Kim, Kap Jung; Ahn, Jae Hoon; Choy, Won Sik; Kim, Yong In; Koo, Jea Yun

    2008-01-01

    The aim of this study was to evaluate the efficacy of tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator for the treatment of leg length discrepancy or short stature. This retrospective study was performed on 18 tibiae (13 patients) in which attempts were made to reduce complications. We used an Ilizarov external fixator and a nail (10 mm diameter in 17 tibiae and 11 mm in one tibia) in combination. Average limb lengthening was 4.19 cm (range, 2.5–5.5). The mean duration of external fixation was 12.58 days per centimetre gain in length, and the mean consolidation index was 40.53 (range, 35.45–51.85). All distracted segments healed spontaneously without refracture or malalignment. Gradual limb lengthening using a reamed type intramedullary nail and circular external fixation in combination was found to be reliable and effective and reduced external fixation time with fewer complications. PMID:18415098

  2. Limb lengthening over a nail can safely reduce the duration of external fixation

    PubMed Central

    Chaudhary, Milind

    2008-01-01

    Background: Limb lengthening using Ilizarov external fixation is safe, but the consolidation phase tends to take too long. A method that can safely reduce the time spent in external fixation would help increase patient tolerance and comfort. We report our results of lengthening over nails (LON) method in which an interlocking nail was used along with an Ilizarov external fixator to reduce external fixation duration in limb lengthening. This is a retrospective study. Materials and Methods: Twenty-seven lengthening surgeries were done with the LON method in 23 patients with 22 tibiae and five femora during the last 12 years. Length gain ranged from 1.5 cm to a maximum of 9.8 cm with a mean of 4.6 cm. The mean modified Paley difficulty score was 7.6 points. Fourteen associated procedures were performed in these patients, including equinus contracture releases, supracondylar osteotomies, ilizarov hip reonstruction and ankle fusion. We had a 29% rate of complications which included one problem, three obstacles and four complications with no serious deep intramedullary infections. Our rate of complications compares favorably with series reported in the literature. External fixation duration was reduced significantly to a mean of 17.8 days per cm. Conclusions: A combination of intramedullary nailing along with external fixation significantly reduces external fixation time while maintaining low rate of complications. Great care needs to be taken to prevent pin track infection and deep intramedullary sepsis. PMID:19753160

  3. [Case-control study on effects of external fixation combined with limited internal fixation for the treatment of Pilon fractures of Rüedi-Allgower type III].

    PubMed

    Duan, Da-Peng; You, Wu-Lin; Ji, Le; Zhang, Yong-Tao; Dang, Xiao-Qian; Wang, Kun-Zheng

    2014-01-01

    To analyze the effects of three surgical operations in the treatment of Pilon fracture of Rüedi-Allgower type III, and put forward the best therapeutic method. The clinical data of 33 patients with Pilon fracture who received surgical operations (plaster immobilization group, 10 cases; distal tibia anatomical plate group, 11 cases; external fixation with limited internal fixation group, 12 cases) from October 2009 to January 2012 were analyzed. There were 5 males and 5 females, ranging in age from 24 to 61 years in the plaster immobilization group. There were 7 males and 4 females, ranging in age from 21 to 64 years in the distal tibia anatomical plate group. There were 7 males and 5 females, ranging in age from 23 to 67 years in the external fixation with limited internal fixation group. The Ankle X-ray of Pilon fracture after operation, ankle score, early and late complications were collected. Bourne system was used to evaluate ankle joint function. After 8 months to 3 years follow-up, it was found that three kinds of treatment had significant differences in the outcomes and complications (P < 0.05): the external fixation with limited internal fixation group got the best results. The number of anatomic reduction cases in the external fixation with limited internal fixation group (7 cases) and the distal tibia anatomical plate group (8 cases) was more than the plaster immobilization group (2 cases). According to the ankle score, 8 patients got an excellent result, 3 good and 1 poor in the limited internal fixation group ,which was better than those of distal tibia anatomical plate group (5 excellent, 4 good and 2 poor) and the plaster immobilization group (3 excellent, 4 good and 3 poor). The number of early and late complications in the external fixation with limited internal fixation group was more than those in the plaster immobilization group and the distal tibia anatomical plate group (P< 0.05). Treatment of external fixation with limited internal fixation in the treatment of Pilon fracture of Rüedi-Allgower type III is effective and safe.

  4. Long-term results of various therapy concepts in severe pilon fractures.

    PubMed

    Koulouvaris, Panagiotis; Stafylas, Kosmas; Mitsionis, Gregory; Vekris, Marios; Mavrodontidis, Alexandros; Xenakis, Theodore

    2007-07-01

    Intra-articular fractures of the tibia plafond are among the most challenging of orthopaedic problems. This is a retrospective case-control study of surgically treated pilon fractures which was undertaken to compare the internal fixation with the two external fixation methods. This is a case-control study of 55 patients with 55 pilon fractures. There were 36 type C and 19 type B. Of these fractures, 24 were open and 31 closed. Three surgical protocols were used. In 20 patients, Group A, a half pin external fixator with ankle spanning was performed. The mean age of patients was 42.0 years (22.0-74.0), SD 14.1 and the mean follow-up was 77.7 months (38.0-132.0), SD 25.4. In 22 patients, Group B, a single ankle sparring ring hybrid external fixator under a small arthrotomy was performed. The mean age of patients was 48.4 years (28.0-76.0), SD 12.4 and mean follow-up was 67.9 months (36.0-132.0), SD 27.8. In 13 patients, Group C, a two-staged internal fixation was performed. The mean age was 45.6 years (30.0-66.0), SD 9.7 and the mean follow-up was 78.6 months (55.0-132.0), SD 25.4. We addressed the dissimilarity of the type of fracture in each group performing supplementary stratified analyses within each fracture type group. Group A had union in 6.9 months, group B in 5.6 months and group C in 5.1 months; P = 0.009. Six patients (Group A), two (Group B), and one (Group C) had limitation of ankle motion; P = 0.47. One patient from group C developed infection and the plate was removed. Four patients (Group A), one (Group B), and one (Group C) have developed posttraumatic arthritis (loss of joint space and pain); P = 0.25. Seven patients from Group A have reduced their activities; P = 0.004. In stratified statistical analysis by type of fracture, the associations noted for both fracture groups combined were also noted separately within each fracture group. In this long term follow-up study, the two-staged internal fixation and the hybrid fixation with small arthrotomy were equally efficacious in achieving bone union. Patients in external fixation with the ankle spanning had a significantly higher rate of delayed union. Also more patients in this group have reduced their activities.

  5. Role of Joshi's external stabilization system with percutaneous screw fixation in high-energy tibial condylar fractures associated with severe soft tissue injuries.

    PubMed

    Gupta, Ashish-Kumar; Sapra, Rahul; Kumar, Rakesh; Gupta, Som-Prakash; Kaushik, Devwart; Gaba, Sahil; Bansal, Mahesh Chand; Dayma, Ratan Lal

    2015-01-01

    The treatment of high-energy tibial condylar fractures which are associated with severe soft tissue injuries remains contentious and challenging. In this study, we assessed the results of Joshi's external stabilization system (JESS) by using the principle of ligamentotaxis and percutaneous screw fixation for managing high-energy tibial condylar fractures associated with severe soft tissue injuries. Between June 2008 and June 2010, 25 consecutive patients who were 17e71 years (mean, 39.7), underwent the JESS fixation for high-energy tibial condylar fractures associated with severe soft tissue injuries. Out of 25 patients, 2 were lost during follow-up and in 1 case early removal of frame was done, leaving 22 cases for final follow-up. Among them, 11 had poor skin condition with abrasions and blisters and 2 were open injuries (Gustilo-Anderson grade I&II). The injury mechanisms were motor vehicle accidents (n=19), fall from a height (n=2) and assault (n=1). The fractures were classified according to Schatzker classification system. There were 7 type-V, 14 type-VI and 1 type-lV Schatzker's tibial plateau fractures. The average interval between the injury and surgery was 6.8 days (range 2-13). The average hospital stay was 13 days (range, 7-22). The average interval between the surgery and full weight bearing was 13.6 weeks (range 11-20). The average range of knee flexion was 121°(range 105°-135°). The normal extension of the knee was observed in 20 patients, and an extensor lag of 5°-8° was noted in 2 patients. The complications included superficial pin tract infections (n=4) with no knee stiffness. JESS with lag screw fixation combines the benefit of traction, external fixation, and limited internal fixation, at the same time as allowing the ease of access to the soft tissue for wound checks, pin care, dressing changes, measurement of compartment pressure, and the monitoring of the neurovascular status. In a nutshell, JESS along with screw fixation offers a promising alternative treatment for high- energy tibial condylar fractures associated with severe soft tissue injuries.

  6. Bilateral tibial lengthening over the nail: our experience of 143 cases.

    PubMed

    Motallebi Zadeh, Nader; Mortazavi, Seyedeh Hamideh; Khaki, Siavash; Heidari, Kazem; Karbasi, Ashraf; Ostad Rahimi, Sedigheh

    2014-09-01

    Using lengthening over an intramedullary nail as a technique for cosmetic purposes improves the individuals' quality of life and provides more satisfactory results due to less external fixator period. This study reports a case series of 143 individuals who underwent bilateral tibial lengthening over an intramedullary nail for cosmetic purposes together with the review of parameters related to the surgery and complications. Level of satisfaction was measured with the standard visual analog scale at least 1 year after removal of external fixator. In this study, mean (SD) age of patients was 26.6 (7.26) years. 85 (59.4%) participants were male and 58 (40.6%) were female. Mean end lengthening of all individuals was 6.65 cm. The mean external fixator period was 93.7 days. Complication rate was 0.74 per segment but it decreased to 0.45 when pin-tract infection was excluded. Complications were categorized based on Paley et al.'s classification as 129 problems, 85 obstacles and no sequelae. Interestingly, 44 (30.8%) individuals had no problem and obstacle. Lengthening over an intramedullary nail provides bone formation in equal quality to that obtained by the conventional Ilizarov method, along with lower rate of complications. The large number of individuals involved in our study is a remarkable benefit which could be used as an appropriate sample to compare results for outcomes and complications.

  7. Use of external fixators for damage-control orthopaedics in natural disasters like the 2005 Pakistan earthquake.

    PubMed

    Awais, Syed; Saeed, Ayesha; Ch, Asad

    2014-08-01

    In the 2005 Pakistan earthquake, the great many injured with multiple fractures and open wounds provided a unique opportunity to practice damage-control orthopaedics. External fixators remain a time-tested tools for operating surgeons on such occasions. The locally manufactured, readily available Naseer-Awais (NA) external fixator filled such needs of this disaster with good outcome. This is a retrospective descriptive study of 19,700 patients that presented over seven months to the two centres established by the lead author (SMA) in Muzaffarabad and Mansehra just one night after the 2005 earthquake. A series of local and foreign orthopaedic surgeon teams operated in succession. The computerised patient data collection of 1,145 operations was retrospectively analysed. Of the 19,700 patients presenting to the SMA centres, 50% had limb injuries. Total fracture fixations were 1,145, of which 295 were external fixations: 185 were applied on the lower limb and 90 on upper limb, the majority were applied on tibia. External fixators are valuable damage-control tools in natural disasters and warfare injuries. The locally manufactured NA external fixator served the needs of the many limb injuries during the 2005 Pakistan earthquake.

  8. Hybrid external fixation in the treatment of tibial pilon fractures: A retrospective analysis of 162 fractures.

    PubMed

    Galante, Vito N; Vicenti, Giovanni; Corina, Gianfranco; Mori, Claudio; Abate, Antonella; Picca, Girolamo; Conserva, Vito; Speciale, Domenico; Scialpi, Lorenzo; Tartaglia, Nicola; Caiaffa, Vincenzo; Moretti, Biagio

    2016-10-01

    To determine the efficacy of hybrid external fixation in the treatment of tibial pilon fractures. Retrospective, multicentre study. Adult patients with tibial pilon fractures treated with hybrid external fixation. Fracture reduction with ligamentotaxis and fixation with XCaliber hybrid external fixator. Fracture union, complications, functional outcome (Mazur Ankle Score). Union was obtained in 159 fractures at an average of 125days; there were three delayed unions and three non-unions. The most frequent complication was superficial pin-track infections (48), all of which responded to local wound care and antibiotics. There were no deep infections and no DVT. Only one fracture had loss of reduction that required frame revision. The overall functional scores were 91 (excellent) for AO/OTA type A fractures, 89 (good) for type B fractures, and 75 (satisfactory) for type C fractures. Hybrid external fixation is an effective method of stabilising tibial pilon fractures, particularly those with marked comminution. The minimally-invasive technique and stable fixation enable early mobilisation, with good functional results and minimal complications. Level IV Case series. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Segmental transport after unreamed intramedullary nailing. Preliminary report of a "Monorail" system.

    PubMed

    Raschke, M J; Mann, J W; Oedekoven, G; Claudi, B F

    1992-09-01

    The Ilizarov method of segmental bone transport has been shown to be an alternative to more conventional treatments of posttraumatic bony defects. After extensive clinical experience with the unreamed tibial nail in open fractures up to Grade IIIb, a new monorail fixation system for callus distraction and segmental bone transport was devised. This Monorail system is composed of an unreamed intramedullary (IM) nail and a unilateral AO distraction device. The new fixation method and the preliminary clinical experience are reported here. Four patients who previously sustained Grades II-IIIb open tibial fractures had an average bony defect of 9 cm. Two patients had previous bony infections. All patients had had serial debridements and myocutaneous flaps were required in three patients. An unreamed IM nail was inserted, and the transport device was applied. After an osteotomy, segmental transport was carried out until docking was achieved. The external fixator was removed after interlocking of the transported segment. The mean duration of external fixation was 17.9 days/cm and the mean period until roentgenographic consolidation of the distraction and nonunion site was 41.2 days/cm. There were two pin-tract infections but no IM infections. One nail broke after osseous consolidation of the regenerate at the distal interlocking site and required exchange. The goal of transport was achieved in all cases without angular or rotational deformity or length discrepancy. There were no neurovascular injuries.

  10. Mechanics of external fixation device of spine: reducing the mounting stress

    NASA Astrophysics Data System (ADS)

    Piven, V. V.; Lyulin, S. V.; Kovalenko, P. I.; Mushtaeva, Yu A.

    2018-03-01

    During the installation of the external fixation device on the spine, there is an occurrence of mounting stress due to misalignment of the rod-screws. To determine the magnitude of the mounting stresses, mathematical dependencies are sometimes used. The proposed technical solution is to reduce stress in the external fixation device.

  11. External fixators in the treatment of midshaft clavicle non-unions: a systematic review.

    PubMed

    Barlow, Tim; Upadhyay, Piyush; Barlow, David

    2014-02-01

    Non- or mal-union of the clavicle is reported to occur in up to 15 % of conservatively treated fractures: the purpose of this systematic review is to examine the evidence for the use of external fixation in the treatment of clavicular non-union. We performed a search of MEDLINE and Embase, including all papers using external fixators for the treatment of clavicular non-union. Four papers satisfied our eligibility criteria: three case series and one case-control study. Level of evidence and quality assessment scoring were performed using published methods. Due to the heterogeneity of the study populations and interventions, no attempt at meta-analysis was made. External fixation in hypertrophic non-union of the clavicle, but not atrophic non-union, appears to be a reasonable treatment option. A pragmatic, multicentre, randomised controlled trial comparing external fixation and open reduction internal fixation in the treatment of hypertrophic non-union of the clavicle would be valuable.

  12. Clinical application of locked plating system in children. An orthopaedic view

    PubMed Central

    Zafra-Jimenez, Jose Alberto; Rodriguez Martin, Juan

    2010-01-01

    In recent years, the locked plating system has gained favour in the treatment of certain fractures in adults; however, there is not much information regarding its use in children. We think there could be some advantages and applications such as: an alternative to external fixation, the bridge plating technique, unicortical screws, removal of hardware, metadiaphyseal fractures, periarticular fractures, poor quality bone, and allograft fixation. However, there are some disadvantages to keep in mind and the final decision for using it should be based on the osteosynthesis method principle the surgeon would like to apply. In this review article we discuss the up-to-date possible clinical applications and issues of this system. PMID:20162415

  13. Endochondral fracture healing with external fixation in the Sost knockout mouse results in earlier fibrocartilage callus removal and increased bone volume fraction and strength.

    PubMed

    Morse, A; Yu, N Y C; Peacock, L; Mikulec, K; Kramer, I; Kneissel, M; McDonald, M M; Little, D G

    2015-02-01

    Sclerostin deficiency, via genetic knockout or anti-Sclerostin antibody treatment, has been shown to cause increased bone volume, density and strength of calluses following endochondral bone healing. However, there is limited data on the effect of Sclerostin deficiency on the formative early stage of fibrocartilage (non-bony tissue) formation and removal. In this study we extensively investigate the early fibrocartilage callus. Closed tibial fractures were performed on Sost(-/-) mice and age-matched wild type (C57Bl/6J) controls and assessed at multiple early time points (7, 10 and 14days), as well as at 28days post-fracture after bony union. External fixation was utilized, avoiding internal pinning and minimizing differences in stability stiffness, a variable that has confounded previous research in this area. Normal endochondral ossification progressed in wild type and Sost(-/-) mice with equivalent volumes of fibrocartilage formed at early day 7 and day 10 time points, and bony union in both genotypes by day 28. There were no significant differences in rate of bony union; however there were significant increases in fibrocartilage removal from the Sost(-/-) fracture calluses at day 14 suggesting earlier progression of endochondral healing. Earlier bone formation was seen in Sost(-/-) calluses over wild type with greater bone volume at day 10 (221%, p<0.01). The resultant Sost(-/-) united bony calluses at day 28 had increased bone volume fraction compared to wild type calluses (24%, p<0.05), and the strength of the fractured Sost(-/-) tibiae was greater than that that of wild type fractured tibiae. In summary, bony union was not altered by Sclerostin deficiency in externally-fixed closed tibial fractures, but fibrocartilage removal was enhanced and the resultant united bony calluses had increased bone fraction and increased strength. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  14. External fixation of tibial pilon fractures and fracture healing.

    PubMed

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  15. [Treatment of posttraumatic cubitus varus in children and adolescents. Supracondylar humeral osteotomy using radial external fixation].

    PubMed

    Slongo, T

    2015-06-01

    Precise adaptable fixation of a supracondylar humerus osteotomy with a radial/lateral external fixator to correct posttraumatic cubitus varus. Acquired, posttraumatic cubitus varus as a result of a malhealed and unsatisfactorily treated supracondylar humerus fracture. Idiopathic, congenital cubitus varus (very seldom) if the child (independent of age and after complete healing) is cosmetically impaired; stability of the elbow is reduced due to malalignment (hyperextension); secondary problems and pain (e. g., irritation of the ulnar nerve) are expected or already exist; or there is an explicit wish of the child/parents (relative indication). In principle there are no contraindications provided that the indication criteria are filled. The common argument of age does not represent a contraindication in our opinion, since angular remodeling at the distal end of the humerus is practically nonexistent. Basically, the surgical technique of the radial external fixator is used as previously described for stabilization of complex supracondylar humeral fractures. With the patient in supine position, the arm is placed freely on an arm table. Using a 4-5 cm long skin incision along the radial, supracondylar, the extracapsular part of the distal humerus is prepared, whereby great caution regarding the radial nerve is advised. In contrast to the procedure used in radial external fixation for supracondylar humeral fracture treatment, two Schanz screws are always fixed in each fragment at a distance of 1.5-2 cm. The osteotomy must allow the fragment to freely move in all directions. The proximal and distal two Schanz screws are then connected with short 4 mm carbon or stainless steel rods. These two rods are connected with each other over another rod using the tub-to-tub technique. Now the preliminary correction according the clinical situation can be performed and the clamps are tightened. Anatomical axis and function are checked. If these are radiologically and clinically perfect, all clamps are definitively tightened; if the alignment or the function is not perfect, then further adjustments can be made. Due to the excellent stability, further immobilization not necessary. Immediate functional follow-up treatment performed according to pain. Adequate healing is usually expected within 6 weeks. At this time the external fixator can be removed in the fracture clinic. Because the whole operation is performed in an extraarticular manner and the mobility of the elbow is not affected, deterioration of function has never been observed. Also regarding the cosmetic/anatomical situation, good results are expected because they were already achieved intraoperatively.

  16. Biomechanical consequences of callus development in Hoffmann, Wagner, Orthofix and Ilizarov external fixators.

    PubMed

    Juan, J A; Prat, J; Vera, P; Hoyos, J V; Sánchez-Lacuesta, J; Peris, J L; Dejoz, R; Alepuz, R

    1992-09-01

    A theoretical analysis by a finite elements model (FEM) of some external fixators (Hoffmann, Wagner, Orthofix and Ilizarov) was carried out. This study considered a logarithmic progress of callus elastic characteristics. A standard configuration of each fixator was defined where design and application characteristics were modified. A comparison among standard configurations and influence of every variation was made with regard to displacement and load transmission at the fracture site. An experimental evaluation of standard configurations was performed with a testing machine. After experimental validation of the theoretical model was achieved, an application of physiological loads which act on a fractured limb during normal gait was analysed. A minimal contribution from an external fixator to the total rigidity of the bone-callus-fixator system was assessed when a callus showing minimum elastic characteristics had just been established. Insufficient rigidity from the fixation devices to assure an adequate immobilization during the early stages of fracture healing was verified. However, regardless of the external fixator, callus development was the overriding element for the rigidity of the fixator-bone system.

  17. Temporary and definitive external fixation of war injuries: use of a French dedicated fixator.

    PubMed

    Mathieu, Laurent; Ouattara, Naklan; Poichotte, Antoine; Saint-Macari, Erwan; Barbier, Olivier; Rongiéras, Fréderic; Rigal, Sylvain

    2014-08-01

    External fixation is the recommended stabilization method for both open and closed fractures of long bones in forward surgical hospitals. Specific combat surgical tactics are best performed using dedicated external fixators. The Percy Fx (Biomet) fixator was developed for this reason by the French Army Medical Service, and has been used in various theatres of operations for more than ten years. The tactics of Percy Fx (Biomet) fixator use were analysed in two different situations: for the treatment of French soldiers wounded on several battlefields and then evacuated to France and for the management of local nationals in forward medical treatment facilities in Afghanistan and Chad. Overall 48 externals fixators were implanted on 37 French casualties; 28 frames were temporary and converted to definitive rigid frames or internal fixation after medical evacuation. The 77 Afghan patients totalled 85 external fixators, including 13 temporary frames applied in Forward Surgical Teams (FSTs) prior to their arrival at the Kabul combat support hospital. All of the 47 Chadian patients were treated in a FST with primary definitive frames because of delayed surgical management and absence of higher level of care in Chad. Temporary frames were mostly used for French soldiers to facilitate strategic air medical evacuation following trauma damage control orthopaedic principles. Definitive rigid frames permitted achieving treatment of all types of war extremity injuries, even in poor conditions.

  18. Salvage of infected total knee fusion: the last option.

    PubMed

    Wiedel, Jerome D

    2002-11-01

    Currently the most common indication for an arthrodesis of the knee is a failed infected total knee prosthesis. Other causes of a failed total knee replacement that might necessitate a knee fusion include aseptic loosening, deficient extensor mechanism, poor soft tissues, and Charcot joint. Techniques available for achieving a knee fusion are external fixation and internal fixation methods. The external fixation compression devices have been the most widely used for knee fusion and have been successful until the indications for fusion changed to mostly failed prosthetic knee replacement. With failed total knee replacement, the problem of severe bone loss became an issue, and the external fixation compression devices, even including the biplane external fixators, have been the least successful method reported for gaining fusion. The Ilizarov technique has been shown to achieve rigid fixation despite this bone loss, and a review of reports are showing high fusion rates using this method. Internal fixation methods including plate fixation and intramedullary nails have had the best success in gaining fusion in the face of this bone loss and have replaced external fixation methods as the technique of choice for knee fusion when severe bone loss is present. A review of the literature and a discussion of different fusion techniques are presented including a discussion of the influence that infection has on the success of fusion.

  19. Use of a Multivector Mandibular Distractor for Treatment of Pediatric Proximal Interphalangeal Joint Pilon Fractures: A Case-Based Review.

    PubMed

    Pedreira, Rachel; Cho, Brian H; Geer, Angela; DeJesus, Ramon A

    2018-04-01

    The difficulties in surgical treatment of pilon fractures of the finger include fragment reconstitution and posthealing stiffness. In adults, external fixation with traction and early active range of motion (AROM)/passive range of motion (PROM) during healing is considered necessary for avoiding joint stiffness and attaining realignment. The authors present a unique approach to pediatric pilon fractures that uses open reduction and multivector external fixation with delayed AROM/PROM. Initial immobilization and significant traction allowed for joint realignment and prevented noncompliance with staged distraction. The authors believe this immobilization leads to a superior outcome because, unlike adults, children tend to avoid stiffness and a larger distraction force allowed for sufficient joint realignment to regain range of motion (ROM). A right-handed 13-year-old boy sustained a right ring finger fracture and presented 12 days later. Radiographs revealed a comminuted Salter-Harris 4 fracture of the middle phalanx. The patient underwent open reduction and placement of multivector external fixation using a pediatric mandibular distractor/fixator. Significant traction was applied to distract the finger to length. Hardware was removed 6 weeks postoperatively and AROM was initiated after splinting. The patient started PROM 8 weeks postoperatively. Strengthening was initiated 2 weeks later. ROM improved and rehabilitation was continued. The patient exhibited nearly equal grip strength 12 weeks postoperatively. At 14 months follow-up, radiographs showed complete healing and joint realignment. There was no deformity or pain and finger length was restored. Management of pediatric pilon fractures is rarely described and presents unique considerations. Early-stage traction and immobilization using a multivector mandibular fixator/distractor is suitable in a child because noncompliance is avoided and there is a decreased risk for stiffness. Combining early immobilization with subsequent-staged AROM, PROM, and strengthening resulted in no loss of ROM and maintained articular symmetry.

  20. [Distraction Osteogenesis is an Effective Method to Lengthen Digits in Congenital Malformations].

    PubMed

    Mann, M; Hülsemann, W; Winkler, F; Habenicht, R

    2016-02-01

    The aim of this study was to investigate the feasible amount of lengthening by distraction osteogenesis in congenital hand deficiencies. A total of 60 patients (1.6-17.8 years) underwent lengthening of 71 bones between 1994 and 2014. Bone lengthening was performed on 46 metacarpals and 25 phalanges. Mostly the first (n=30) and the fifth (n=21) rays were lengthened. Bone lengthening was performed to treat primarily symbrachydactyly (b=32) and amniotic band syndrome (n=10). To analyze the amount of lengthening preoperative radiographs and radiographs taken while removing the external fixator were compared. The charts were reviewed regarding age at surgery, duration of lengthening, duration of bony consolidation, complication, etc. The average of metacarpal distraction was 18.4 mm=73% lengthening with respect to the preoperative length; the average of phalange distraction was 14.0 mm=77% of the preoperative length. In both, metacarpals and phalanges, a lengthening of > 100% of the preoperative bone length was possible. In target length was reached in 89% of the procedures. The average time for consolidation was 6.1 (1-20) days/mm lengthening. The external fixator was in use on average for 140 (50-346) days. After removing of the external fixator an axial K-wire was used to stabilize the callus in 9 procedure, and an iliac bone craft plus axial K-wire in 11 procedures. The rate of complications was 30% (early consolidation, deviation, joint dislocation, pin infection, tendon dislocation). All complications could be treated without with acceptable results. Metacarpal and phalangeal distraction lengthening is an effective but demanding technique for ray reconstruction in congenital malformations of the hand. It is possible to lengthen a bone by more than 100%. Complications are common, but in most cases easy to handle. © Georg Thieme Verlag KG Stuttgart · New York.

  1. [Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    PubMed

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2017-11-07

    Objective: To make a systematic assessment of the Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Methods: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed. The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected. The included trials were screened out strictly based on the criterion of inclusion and exclusion. The quality of included trials was evaluated. RevMan 5.0 was used for data analysis. Results: Sixteen studies involving 1 268 patients were included. There were 618 patients with open reduction and internal fixation and 650 with external fixation. The results of meta-analysis indicated that there were statistically significant differences with regard to the complications postoperatively (infection( I (2)=0%, RR =0.27, 95% CI 0.16-0.45, Z =4.92, P <0.000 01) and total complications( I (2)=0%, RR =0.71, 95% CI 0.59-0.85, Z =3.65, P =0.000 3) ), DASH scores( I (2)=37%, MD =-5.67, 95% CI -8.31--3.04, Z =4.22, P <0.000 1) and volar tilt( I (2)=78%, MD =2.29, 95% CI 0.33-4.24, Z =2.30, P =0.02)( P <0.05) at the end of follow-up period were noted. There were no statistically significant differences observed between two approaches with respect to the clinical outcomes (grip strength, flexion, extension, pronation, supination, radial deviation and ulnar deviation) and radiographic outcome(radial length) at the end of follow-up period( P <0.05). Conclusion: Both open reduction and internal fixation and external fixation are effective treatment for unstable distal radius fractures. Compared with external fixation, open reduction and internal fixation provides reduced complications postoperatively, lower DASH scores and better restoration of volar tilt for treatment of distal radius fractures.

  2. Application of 3D printed customized external fixator in fracture reduction.

    PubMed

    Qiao, Feng; Li, Dichen; Jin, Zhongmin; Gao, Yongchang; Zhou, Tao; He, Jinlong; Cheng, Li

    2015-01-01

    Long bone fracture is common in traumatic osteopathic patients. Good reduction is beneficial for bone healing, preventing the complications such as delayed union, nonunion, malunion, but is hard to achieve. Repeated attempts during the surgery would increase the operation time, cause new damage to the fracture site and excessive exposure to radiation. Robotic and navigation techniques can help improve the reduction accuracy, however, the high cost and complexity of operation have limited their clinical application. We combined 3D printing with computer-assisted reduction technique to develop a customised external fixator with the function of fracture reduction. The original CT data obtained by scanning the fracture was imported to computer for reconstructing and reducing the 3D image of the fracture, based on which the external fixator (named as Q-Fixator) was designed and then fabricated by 3D printing techniques. The fracture reduction and fixation was achieved by connecting the pins inserted in the bones with the customised Q-Fixator. Experiments were conducted on three fracture models to demonstrate the reduction results. Good reduction results were obtained on all three fractured bone models, with an average rotation of 1.21°(± 0.24), angulation of 1.84°(± 0.28), and lateral displacement of 2.22 mm(± 0.62). A novel customised external fixator for long bone fracture reduction was readily developed using 3D printing technique. The customised external fixator had the advantages of easy manipulation, accurate reduction, minimally invasion and experience-independence. Future application of the customised external fixator can be extended to include the fixation function with stress adjustment and potentially optimise the fracture healing process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Hinged external fixation of the elbow.

    PubMed

    Chen, Neal C; Julka, Abhishek

    2010-08-01

    Hinged external fixation of the elbow provides the advantages of static fixation with the benefits of continued motion through the joint. Indications for the use of this method of fixation include traumatic instability, distraction interposition arthroplasty, instability after contracture release, and instability after excision of heterotopic ossification. Orthopedic surgeons should be familiar with hinged fixators and their application when faced with an unstable ulnohumeral joint. 2010 Elsevier Inc. All rights reserved.

  4. Internal Versus External Fixation of Charcot Midfoot Deformity Realignment.

    PubMed

    Lee, Daniel J; Schaffer, Joseph; Chen, Tien; Oh, Irvin

    2016-07-01

    Internal and external fixation techniques have been described for realignment and arthrodesis of Charcot midfoot deformity. There currently is no consensus on the optimal method of surgical reconstruction. This systematic review compared the clinical results of surgical realignment with internal and external fixation, specifically in regard to return to functional ambulation, ulcer occurrence, nonunion, extremity amputation, unplanned further surgery, deep infection, wound healing problems, peri- or intraoperative fractures, and total cases with any complication. A search of multiple databases for all relevant articles published from January 1, 1990, to March 22, 2014, was performed. A logistic regression model evaluated each of the outcomes and its association with the type of fixation method. The odds of returning to functional ambulation were 25% higher for internal fixation (odds ratio [OR], 1.259). Internal fixation had a 42% reduced rate of ulcer occurrence (OR, 0.578). External fixation was 8 times more likely to develop radiographic nonunion than internal fixation (OR, 8.2). Internal fixation resulted in a 1.5-fold increase in extremity amputation (OR, 1.488), a 2-fold increase in deep infection (OR, 2.068), a 3.4-fold increase in wound healing complications (OR, 3.405), and a 1.5-fold increase in the total number of cases experiencing any complication (OR, 1.525). This was associated with a 20% increase in the need for unplanned further surgery with internal fixation (OR, 1.221). Although internal fixation may decrease the risk of nonunion and increase return to functional ambulation, it had a higher rate of overall complications than external fixation for realignment and arthrodesis of Charcot midfoot deformity. [Orthopedics. 2016; 39(4):e595-e601.]. Copyright 2016, SLACK Incorporated.

  5. Prevention of Thumb Web Space Contracture With Multiplanar External Fixation.

    PubMed

    Harper, Carl M; Iorio, Matthew L

    2016-09-01

    Thumb web space contracture following hand trauma can be disabling with numerous reconstructive procedures existing to correct the resultant deformity. Following marked soft tissue injury to the hand we utilized the Stryker Hoffmann II Micro External Fixator System to link the first and second metacarpals by a multiplanar system using 1.6 or 2.0 mm self-drilling half-pins and 3 mm carbon fiber connecting rods. This facilitated placement of the thumb in maximal palmar abduction as well as allowed adjustment of thumb position throughout the postoperative period. This technique was performed on 5 patients. Two patients were treated with a first web space external fixator for table saw injuries to the radial aspect of the hand. An additional 2 patients were treated with a first web space external fixator following metacarpophalangeal joint capsular release in the setting of thermal burns. A fifth patient underwent second ray amputation, trapeziectomy and trapezoidectomy for squamous cell carcinoma with subsequent stabilization with the external fixator. The external fixator was left in place until soft tissues were healed (average 5.5 wk). The patients were allowed to mobilize their hand in as much as the external fixator allowed, and no device-associated complications were noted. Thumb web space was preserved with passive and supple thumb circumduction and web space abduction/adduction in all patients at an average follow-up of 5 months. The average Quick Dash Score was 35±5 and the average Modern Activity Subjective Survey of 2007 was 30±8.

  6. Influence of fixation point of latissimus dorsi tendon transfer for irreparable rotator cuff tear on glenohumeral external rotation: A cadaver study.

    PubMed

    Bargoin, K; Boissard, M; Kany, J; Grimberg, J

    2016-12-01

    Latissimus dorsi tendon transfer is a surgical option for treating irreparable posterosuperior rotator cuff tears, notably when attempting to reconstruct active external rotation. We hypothesized that the positioning of the transfer's point of fixation would differ depending on the desired elbow-to-body external rotation or external rotation with the elbow abducted. Seven shoulders from four whole frozen cadavers were used. We created two systems to install the subject in a semi-seated position to allow external rotation elbow to body and the arm abducted 90°. Traction sutures were positioned on the latissimus dorsi muscle and a massive tear of the rotator cuff was created. We tested six different transfer positions. Muscle contraction of the latissimus dorsi was stimulated using 10-N and 20-N suspended weights. The point of fixation of the latissimus dorsi on the humeral head had an influence on the elbow-to-body external rotation and with 90° abduction (P<0.001). The fixation point for a maximum external rotation with the elbow to the body was the anterolateral position (P<0.016). The fixation point for a maximum external rotation at 90° abduction was the position centered on the infraspinatus footprint (P<0.078). The optimal point of fixation differs depending on whether external rotation is restored at 0° or 90° abduction. Fundamental study, anatomic study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Minimally invasive treatment of tibial pilon fractures through arthroscopy and external fixator-assisted reduction.

    PubMed

    Luo, Huasong; Chen, Liaobin; Liu, Kebin; Peng, Songming; Zhang, Jien; Yi, Yang

    2016-01-01

    The aim of this study was to evaluate the clinical outcome of tibial pilon fractures treated with arthroscopy and assisted reduction with an external fixator. Thirteen patients with tibial pilon fractures underwent assisted reduction for limited lower internal fixation with an external fixator under arthroscopic guidance. The weight-bearing time was decided on the basis of repeat radiography of the tibia 3 months after surgery. Postoperative ankle function was evaluated according to the Mazur scoring system. Healing of fractures was achieved in all cases, with no complications such as severe infection, skin necrosis, or an exposed plate. There were 9 excellent, 2 good, and 2 poor outcomes, scored according to the Mazur system. The acceptance rate was 85%. Arthroscopy and external fixator-assisted reduction for the minimally invasive treatment of tibial pilon fractures not only produced less trauma but also protected the soft tissues and blood supply surrounding the fractures. External fixation could indirectly provide reduction and effective operative space for arthroscopic implantation, especially for AO type B fractures and partial AO type C1 fractures.

  8. Preventing Seal Leak During Negative Pressure Wound Therapy Near External Fixators: A Technical Tip.

    PubMed

    Mannino, Brian J; Pullen, Michael W; Gaines, Robert

    2017-03-01

    Negative pressure wound therapy is an effective tool for the treatment of open wounds. Occasionally these wounds are associated with injuries or procedures that require treatment with an external fixator. This article shows how a simple, inexpensive, and commercially available product can be used to prevent loss of suction around external fixator pins within the negative pressure wound treatment area.

  9. Comparison of 39 post-traumatic tibia bone transports performed with and without the use of an intramedullary rod: the long-term outcomes.

    PubMed

    Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian; Wiebking, Ulrich; Hankemeier, Stefan

    2011-09-01

    Bone transport can be performed with an external fixator alone or with the monorail technique which entails the combination of a fixator and an intramedullary nail. The purpose of this study was to compare the complication rates and long-term outcomes of these methods. Two groups of patients, the external fixator (n = 21) and the monorail group (n = 18), were compared. The average follow-up period was 7.9 ± 5.6 years and the mean defect length 8.3 ± 3.1 cm. Healing was achieved in 19 (90%) and 13 (72%) of the fixator and monorail patients, respectively. Six patients underwent amputations because of persistent infections (two in the fixator and four in the monorail group). The rate of deformities was significantly higher in the fixator group (p = 0.049). No statistically significant difference was found when comparing categories of the SF-36 test or the ability to work or do sports. The main advantages of the monorail method are reduction of the external fixation time and the lower rate of deformities. However, the authors recommend segmental transport with external fixator in patients with chronic infections.

  10. External fixation techniques for distal radius fractures.

    PubMed

    Capo, John T; Swan, Kenneth G; Tan, Virak

    2006-04-01

    Fractures of the distal radius are common injuries. Low-energy or high-energy mechanisms may be involved. Unstable distal radius fractures present a challenge to the treating orthopaedic surgeon. External fixation is a valuable instrument for fracture reduction and stabilization. Limited open incisions, early range of motion, and treatment of complex wounds are a few of the benefits of external fixation. Fixators may be spanning or nonbridging and may be used alone or in combination with other stabilization methods to obtain and maintain distal radius fracture reduction. Augmentation with percutaneous wires allows for optimal fracture stabilization with physiologic alignment of the wrist. Moderate distraction at the carpus does not induce postoperative stiffness. The distal radioulnar joint must be assessed and may need to be stabilized. Complications of external fixation are usually minor, but must be anticipated and treated early. Level V (expert opinion).

  11. Operative treatment of early infection after internal fixation of limb fractures (exclusive of severe open fractures).

    PubMed

    Bonnevialle, P

    2017-02-01

    Early infection after open reduction and internal fixation (ORIF) of a limb bone is defined as bacteriologically documented, deep and/or superficial surgical-site infection (SSI) diagnosed within 6months after the surgical procedure. This interval is arbitrarily considered sufficient to obtain fracture healing. The treatment of early infection after ORIF should be decided by a multidisciplinary team. The principles are the same as for revision arthroplasty. Superficial SSIs should be differentiated from deep SSIs, based on the results of bacteriological specimens collected using flawless technique. A turning point in the local microbial ecology occurs around the third or fourth week, when a biofilm develops around metallic implants. This biofilm protects the bacteria. The treatment relies on both non-operative and operative measures, which are selected based on the time to occurrence of the infection, condition of the soft tissues, and stage of bone healing. Both the surgical strategy and the antibiotic regimen should be determined during a multidisciplinary discussion. When treating superficial SSIs after ORIF, soft-tissue management is the main challenge. The treatment differs according to whether the hardware is covered or exposed. Defects in the skin and/or fascia can be managed using reliable reconstructive surgery techniques, either immediately or after a brief period of vacuum-assisted closure. In deep SSIs, deciding whether to leave or to remove the hardware is difficult. If the hardware is removed, the fracture site can be stabilised provisionally using either external fixation or a cement rod. Once infection control is achieved, several measures can be taken to stimulate bone healing before the end of the classical 6-month interval. If the hardware was removed, then internal fixation must be performed once the infection is eradicated. Copyright © 2016. Published by Elsevier Masson SAS.

  12. Tibial plafond fractures: limited incision reduction with percutaneous fixation.

    PubMed

    Salton, Heather L; Rush, Shannon; Schuberth, John

    2007-01-01

    This study was a retrospective review of 18 patients with 19 pilon fractures treated with limited incision reduction and percutaneous plate fixation of the tibia. Patients were treated with either a 1- or 2-stage protocol. The latter consisted of placement of an external fixator followed by definitive reduction. The emphasis of analysis was placed on the identification of complications to the soft tissue envelope or bone-healing problems within the first 6 months after surgery. A major complication was defined as an unplanned operation within the first 6 months. Minor complications were any superficial wound defects that did not require operative intervention to resolve or any malunion or delayed union. With this protocol, no major complications were encountered. Minor complications were identified in 4 patients (4 fractures) of which 2 were minor wound problems. One patient developed a malunion, and the other had a delayed union. Four patients requested removal of prominent hardware. These results indicate that limited incision reduction and percutaneous plate fixation lead to safe methods of stabilization. The authors also provide guidance and strategies for the consistent execution of this technique.

  13. External versus internal fixation for bicondylar tibial plateau fractures: systematic review and meta-analysis.

    PubMed

    Metcalfe, David; Hickson, Craig J; McKee, Lesley; Griffin, Xavier L

    2015-12-01

    It is uncertain whether external fixation or open reduction internal fixation (ORIF) is optimal for patients with bicondylar tibial plateau fractures. A systematic review using Ovid MEDLINE, Embase Classic, Embase, AMED, the Cochrane Library, Open Grey, Orthopaedic Proceedings, WHO International Clinical Trials Registry Platform, Current Controlled Trials, US National Institute for Health Trials Registry, and the Cochrane Central Register of Controlled Trials. The search was conducted on 3rd October 2014 and no language limits were applied. Inclusion criteria were all clinical study designs comparing external fixation with open reduction internal fixation of bicondylar tibial plateau fractures. Studies of only one treatment modality were excluded, as were those that included unicondylar tibial plateau fractures. Treatment effects from studies reporting dichotomous outcomes were summarised using odds ratios. Continuous outcomes were converted to standardized mean differences to assess the treatment effect, and inverse variance methods used to combine data. A fixed effect model was used for meta-analyses. Patients undergoing external fixation were more likely to have returned to preinjury activities by six and twelve months (P = 0.030) but not at 24 months follow-up. However, external fixation was complicated by a greater number of infections (OR 2.59, 95 % CI 1.25-5.36, P = 0.01). There were no statistically significant differences in the rates of deep infection, venous thromboembolism, compartment syndrome, or need for re-operation between the two groups. Although external fixation and ORIF are associated with different complication profiles, both are acceptable strategies for managing bicondylar tibial plateau fractures.

  14. Treatment of unstable distal radius fractures: non-invasive dynamic external fixator versus volar locking plate – functional and radiological outcome in a prospective case-controlled series

    PubMed Central

    Bajwa, Ali S.; Rammappa, Manju; Lee, Ling; Nanda, Rajesh

    2015-01-01

    Introduction: Distal radius fracture (DRF) is a common injury and various treatment modalities including open reduction and internal fixation (ORIF) with volar locking plate are available. More recently, a non-invasive external fixator has been used. Aims: To prospectively compare the use of a non-invasive external fixator with early dynamisation for DRF against ORIF with volar locking plate control group. Methods: Consecutive patients with closed DRF were included in a prospective case-controlled study. Patients were assigned to non-invasive external fixator or ORIF. Minimum follow-up was two years. Follow-up was at weeks 2, 4, 6, 8, 12, 26 and at one and two-year post-operatively. The outcome measures included demographic details, injury mechanism, AO fracture type, risk factors, body mass index (BMI), ulnar styloid fracture and dorsal comminution, radiographs, grip strength and DASH score. Results: Consecutive 50 patients were treated either with non-invasive external fixator (25/50) or with ORIF (25/50) and the mean age of the two groups was 53 years (SD 17.1) and 49 years (SD 19.5), respectively. Demographics were matched in two groups. In the non-invasive external fixator group, there were 10 AO Type-A, 5 Type-B and 10 Type-C fractures. The ORIF group included 8 Type-A, 6 Type-B and 11 Type-C fractures. The mean DASH score at three-months and one-year post-injury in non-invasive fixator group was 12.2 (SD 3.1) and 3.5 (SD 0.7), respectively, significantly greater than those of ORIF group 14.5 (SD 5.6) and 11.2 (SD 4.4), respectively (p < 0.05). Conclusion: DRF treated with non-invasive external fixator can give functional results superior to ORIF at three-months and the trend is maintained at one and two-year post-operatively. PMID:27163089

  15. Diluted povidone-iodine versus saline for dressing metal-skin interfaces in external fixation.

    PubMed

    Chan, C K; Saw, A; Kwan, M K; Karina, R

    2009-04-01

    To compare infection rates associated with 2 dressing solutions for metal-skin interfaces. 60 patients who underwent distraction osteogenesis with external fixators were equally randomised into 2 dressing solution groups (diluted povidone-iodine vs. saline). Fixations were attained using either rigid stainless steel 5-mm diameter half pins or smooth stainless steel 1.8-mm diameter wires. Half-pin fixation had one metal-skin interface, whereas wire fixation had 2 interfaces. Patients were followed up every 2 weeks for 6 months. Of all 788 metal-skin interfaces, 143 (18%) were infected: 72 (19%) of 371 in the diluted povidone-iodine group and 71 (17%) of 417 in the saline group. Dressing solution and patient age did not significantly affect infection rates. Half-pin fixation was more likely to become infected than wire fixation (25% vs 15%). Saline is as effective as diluted povidone-iodine as a dressing solution for metal-skin interfaces of external fixators. Saline is recommended in view of its easy availability and lower costs.

  16. Femoral Reconstruction Using External Fixation

    PubMed Central

    Palatnik, Yevgeniy; Rozbruch, S. Robert

    2011-01-01

    Background. The use of an external fixator for the purpose of distraction osteogenesis has been applied to a wide range of orthopedic problems caused by such diverse etiologies as congenital disease, metabolic conditions, infections, traumatic injuries, and congenital short stature. The purpose of this study was to analyze our experience of utilizing this method in patients undergoing a variety of orthopedic procedures of the femur. Methods. We retrospectively reviewed our experience of using external fixation for femoral reconstruction. Three subgroups were defined based on the primary reconstruction goal lengthening, deformity correction, and repair of nonunion/bone defect. Factors such as leg length discrepancy (LLD), limb alignment, and external fixation time and complications were evaluated for the entire group and the 3 subgroups. Results. There was substantial improvement in the overall LLD, femoral length discrepancy, and limb alignment as measured by mechanical axis deviation (MAD) and lateral distal femoral angle (LDFA) for the entire group as well as the subgroups. Conclusions. The Ilizarov external fixator allows for decreased surgical exposure and preservation of blood supply to bone, avoidance of bone grafting and internal fixation, and simultaneous lengthening and deformity correction, making it a very useful technique for femoral reconstruction. PMID:21991425

  17. External fixation for severe open fractures of the humerus caused by missiles.

    PubMed

    Zinman, C; Norman, D; Hamoud, K; Reis, N D

    1997-10-01

    To evaluate the use of external fixation of the humerus after missile injuries. Retrospective. University medical center. Twenty-six soldiers with twenty-six open Gustilo type III fractures. Immediate external fixation. Clinical, functional, social, and rehabilitation criteria were evaluated. Excellent in fourteen patients (61%), good in four (17%), fair in three (13%), and poor in two (9%). All fractures eventually healed. External fixation is the preferred initial treatment for stabilizing severe open missile fractures of the humerus. Its use, together with radical debridement of dead bone, has reduced the incidence of chronic infection and improved the prognosis of vascular repairs. As a result, the rate of morbidity and upper limb amputation has been reduced significantly, compared with our previous experience.

  18. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.

    PubMed

    Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M

    2015-12-01

    This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.

  19. [High tibial osteotomy--fixation by means of external fixation--indication, technique, complications (author's transl)].

    PubMed

    Klems, H

    1976-02-01

    High tibial osteotomy has proved its value in the treatment of gonarthrosis with or without axis deformity. The thrust of weight-bearing and other stresses is lessened on the degenerated tibial condyle and transferred to the more normal condyle. The stable fixation by means of external fixation allows early movement of the knee joint.-R-ferences to operative technique, indication, complications and after-treatment.

  20. Influence of removal of invisible fixation on the saccadic and manual gap effect.

    PubMed

    Ueda, Hiroshi; Takahashi, Kohske; Watanabe, Katsumi

    2014-01-01

    Saccadic and manual reactions to a peripherally presented target are facilitated by removing a central fixation stimulus shortly before a target onset (the gap effect). The present study examined the effects of removal of a visible and invisible fixation point on the saccadic gap effect and the manual gap effect. Participants were required to fixate a central fixation point and respond to a peripherally presented target as quickly and accurately as possible by making a saccade (Experiment 1) or pressing a corresponding key (Experiment 2). The fixation point was dichoptically presented, and visibility was manipulated by using binocular rivalry and continuous flash suppression technique. In both saccade and key-press tasks, removing the visible fixation strongly quickened the responses. Furthermore, the invisible fixation, which remained on the display but suppressed, significantly delayed the saccadic response. Contrarily, the invisible fixation had no effect on the manual task. These results indicate that partially different processes mediate the saccadic gap effect and the manual gap effect. In particular, unconscious processes might modulate an oculomotor-specific component of the saccadic gap effect, presumably via subcortical mechanisms.

  1. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    PubMed

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  2. Bacteria on external fixators: which prep is best?

    PubMed

    Stinner, Daniel J; Beltran, Michael J; Masini, Brendan D; Wenke, Joseph C; Hsu, Joseph R

    2012-03-01

    There are no established guidelines for the surgical prep of an external fixator in the operative field. This study investigates the effectiveness of different prep solutions and methods of application. Forty external fixator constructs, consisting of a rod, pin, and pin to rod coupling device, were immersed in a broth of Staphylococcus aureus (lux) for 12 hours. Constructs were then randomized into four treatment groups: chlorhexidine-gluconate (CHG) (4%) scrub, CHG (4%) spray, povidone-iodine (PI) (10%) scrub, and PI (10%) spray. Each construct was imaged with a specialized photon capturing camera system yielding the quantitative and spatial distribution of bacteria both before and after the prep. Each pin to bar clamp was loosened and moved 2 cm down the construct, simulating an external fixator adjustment, and reimaged. Spatial distribution of bacteria and total bacteria counts were compared. There was a similar reduction in bacteria after surgical prep when comparing all four groups independently (p = 0.19), method of application (spray vs. scrub, p = 0.27), and different solutions (CHG vs. PI, p = 0.41). Although bacteria were evident in newly exposed areas after external fixator adjustment, most notably within the loosened pin to bar clamp, it did not result in an increase in bacteria counts (all four groups, p = 0.11; spray vs. scrub, p = 0.18; CHG vs. PI, p = 0.99). Although there was no increase in bacteria counts after the simulated external fixator adjustment, it did expose additional bacteria previously unseen. Although there was no difference in surgical prep solution or method of application, consideration must be given to performing an additional surgical prep of the newly exposed surface after loosening of each individual external fixator component as this may further minimize potential bacteria exposure.

  3. A comparison of two techniques for knee arthrodesis: the custom made intramedullary Mayday nail versus a monoaxial external fixator.

    PubMed

    Yeoh, David; Goddard, Richard; Macnamara, Paul; Bowman, Nicholas; Miles, Kim; East, Debra; Butler-Manuel, Adrian

    2008-08-01

    The most common indication for knee arthrodesis is pain and instability in an unreconstructable knee following an infected knee arthroplasty. In this study, we compare the use of the Mayday arthrodesis nail (Orthodynamics, Christchurch, UK) versus external fixation, Orthofix (Berkshire UK) and Stryker Hoffman II (County Cork, Ireland). All patients in this study underwent arthrodesis between 1995 and 2006 at Conquest Hospital, Hastings. In group A, 11 patients underwent arthrodesis with a Mayday nail. In all cases, the indications were infected total knee replacements (TKR). Three of these patients previously had failed attempts at arthrodesis with external fixation devices. In group B, seven patients underwent arthrodesis using external fixation. In six patients, the indication was infected TKRs. Results were reviewed retrospectively, with union assessed both clinically and radiologically. The mean inpatient stay for the Mayday nail group was 23 days (range 8-45 days) compared with 76 days (range 34-122) for the external fixation group (p<0.01, CI 95). Ten patients in group A went on to confirmed primary arthrodesis. One patient underwent revision arthrodesis with a Mayday nail and subsequently united. In group B only two patients achieved union. The rate of union was significantly greater in the Mayday nail group than the external fixation group (91% vs 29%, p<0.01). Of those patients that achieved union, there was no difference in the time to fusion between groups. Our study supported the existing literature and found that the Mayday nail appeared more effective than monoaxial external fixators for arthrodesis in the management of infected total knee replacements.

  4. [Surgical treatment of tibial nonunion after wounding by high velocity missile and external fixators: a case report].

    PubMed

    Golubović, Ivan; Vukašinović, Zoran; Stojiljković, Predrag; Golubović, Zoran; Stojiljković, Danilo; Radovanović, Zoran; Ilić, Nenad; Najman, Stevo; Višnjić, Aleksandar; Arsić, Stojanka

    2012-01-01

    The missiles of modern firearms can cause severe fractures of the extremity. High velocity missile fractures of the tibia are characterized by massive tissue destruction and primary contamination with polymorphic bacteria. Treatment of these fractures is often complicated by delayed healing, poor position healing, nonhealing and bone tissue infection. We present the management of tibial nonunion after wounding by high velocity missile and primary treatment by external fixation in a 25-year-old patient. The patient was primarily treated with external fixation and reconstructive operations of the soft tissue without union of the fracture. Seven months after injury we placed a compression-distraction external fixator type Mitkovic and started with compression and distraction in the fracture focus after osteotomy of the fibula and autospongioplasty. We recorded satisfactory fracture healing and good functional outcome. Contamination and devitalization of the soft-tissue envelope increase the risk of infection and nonunion in fractures after wounding by high velocity missile. The use of the compression-distraction external fixator type Mitkovic may be an effective method in nonunions of the tibia after this kind of injury.

  5. Long-bone fractures in llamas and alpacas: 28 cases (1998–2008)

    PubMed Central

    Knafo, S. Emmanuelle; Getman, Liberty M.; Richardson, Dean W.; Fecteau, Marie-Eve

    2012-01-01

    Treatment and outcome of camelids with long-bone fractures are described. Medical records (1998–2008) of camelids (n = 28) with long-bone fractures were reviewed for signalment, time to presentation, fracture type, method of repair, duration of hospitalization, and post-operative complications. Follow-up information was obtained via telephone interviews with owners. Mean age and weight at presentation were 3.4 years and 56.3 kg, respectively. Twenty-six fractures were treated with internal fixation (n = 11), external fixation (n = 10), combination of internal and external fixation (n = 3), amputation (n = 1), and external fixation followed by amputation (n = 1). Long-term follow-up information was obtained for 19 of the 26 animals. The post-operative complication rate was 23% and owner satisfaction was high. Animals with open fractures were more likely to experience complications. Internal fixation was associated with superior alignment and outcome. Internal fixation techniques should be recommended for camelids. PMID:23277645

  6. Long-bone fractures in llamas and alpacas: 28 cases (1998-2008).

    PubMed

    Knafo, S Emmanuelle; Getman, Liberty M; Richardson, Dean W; Fecteau, Marie-Eve

    2012-07-01

    Treatment and outcome of camelids with long-bone fractures are described. Medical records (1998-2008) of camelids (n = 28) with long-bone fractures were reviewed for signalment, time to presentation, fracture type, method of repair, duration of hospitalization, and post-operative complications. Follow-up information was obtained via telephone interviews with owners. Mean age and weight at presentation were 3.4 years and 56.3 kg, respectively. Twenty-six fractures were treated with internal fixation (n = 11), external fixation (n = 10), combination of internal and external fixation (n = 3), amputation (n = 1), and external fixation followed by amputation (n = 1). Long-term follow-up information was obtained for 19 of the 26 animals. The post-operative complication rate was 23% and owner satisfaction was high. Animals with open fractures were more likely to experience complications. Internal fixation was associated with superior alignment and outcome. Internal fixation techniques should be recommended for camelids.

  7. Does pediatric body mass index affect surgical outcomes of lower-extremity external fixation?

    PubMed

    Fedorak, Graham T; Cuomo, Anna V; Otsuka, Norman Y

    2015-06-01

    Obese patients are highly prevalent in the pediatric orthopaedic surgeon's practice and obesity is an increasing issue in the United States. Increased body mass index (BMI) has been associated with increased complications in pediatric orthopaedic patients, but no study has looked specifically at external fixation. The purpose of this study was to determine whether obesity is a risk factor for increased complications in lower-extremity procedures requiring external fixation. A retrospective chart review was conducted of pediatric patients who underwent external fixation as definitive operative treatment for any condition at a tertiary care hospital over a 15-year period. Patients were grouped into normal weight, overweight, and obese based on Centers for Disease Control definitions. All orthopaedic complications were recorded. A total of 208 patients with a mean age of 11.2 years were identified. Ninety-four children were obese at the 95th percentile BMI or higher, 22 were overweight and 93 were normal weight. External fixation was applied to the tibia in 82 cases, to the femur in 77 and to both in 49. Mean duration of fixation was 160 days (range, 31 to 570 d) and patients were followed for a mean of 3.9 years (range, 1.0 to 12.0 y). There was no statistically significant difference in the rate of complications between the 3 groups (P=0.61). In the obese group complications occurred in 68.1% versus 66.7% in the overweight group and 61.3% in normal weight. In the setting of external fixator use for lower-extremity pathology in pediatric patients, there is no association between an increase in complications and obesity as defined by BMI. Complication rates are high when external fixation is utilized for the lower extremity, however, patients and families should not be counseled that increased BMI will add to the burden of orthopaedic complications in this situation. Level II-prognostic.

  8. An Overview of Internal and External Fixation Methods for the Diabetic Charcot Foot and Ankle.

    PubMed

    Ramanujam, Crystal L; Zgonis, Thomas

    2017-01-01

    Diabetic Charcot neuroarthropathy (DCN) of the foot and ankle is a challenging disease with regard to clinical presentation, pathogenesis, and prognosis. Its surgical management is equally difficult to interpret based on the wide array of options available. In the presence of an ulceration or concomitant osteomyelitis, internal fixation by means of screws, plates, or intramedullary nailing needs to be avoided when feasible. External fixation becomes a great surgical tool when managing DCN with concomitant osteomyelitis. This article describes internal and external fixation methods along with available literature to enlighten surgeons faced with treating this complex condition. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Ankle fracture syndesmosis fixation and management: the current practice of orthopedic surgeons.

    PubMed

    Bava, Eric; Charlton, Timothy; Thordarson, David

    2010-05-01

    There is a wide variety of treatments for disruption of the syndesmosis. There is also controversy as to which device should be used for fixation of the syndesmosis, how many devices should be used, how many cortices the screws should engage, and whether, when, and where the screws should be removed. We conducted a study to determine how orthopedic surgeons manage these injuries. In a survey, we asked orthopedic trauma and foot and ankle fellowship directors and members of the Orthopaedic Trauma Association and the American Orthopaedic Foot and Ankle Society how they routinely treated the syndesmotic injury component of Danis-Weber type C or Lauge-Hansen pronation-external rotation type IV ankle fractures. The overall response rate was 50% (77/153). Fifty-one percent of respondents routinely used 3.5-mm cortical screws, 24% routinely used 4.5-mm cortical screws, and 14% routinely used a suture fixation device. Forty-four percent of respondents routinely used 1 screw, 44% routinely used 2 screws, and the rest were undecided between 1 and 2 screws. Twenty-nine percent of respondents engaged 3 cortices with syndesmotic screws, and 67% engaged 4 cortices. Syndesmotic screws were routinely removed 65% of the time and left in place 35% of the time. Routine removal of syndesmotic screws was done in the operating room in 95% of cases; it was done at 3 months in 49% of cases, at 4 months in 37%, and at 6 months in 12%. The most common method for treating syndesmotic injuries was through use of 3.5-mm screws engaging 4 cortices routinely removed in the operating room at 3 months. Number of screws used to fix the syndesmosis, either 1 or 2, was evenly split.

  10. External fixation is more suitable for intra-articular fractures of the distal radius in elderly patients

    PubMed Central

    Ma, Chuang; Deng, Qiang; Pu, Hongwei; Cheng, Xinchun; Kan, Yuhua; Yang, Jing; Yusufu, Aihemaitijiang; Cao, Li

    2016-01-01

    The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after 1 week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P=0.001), supination, (P=0.047) and extension (P=0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at 1 year. The plating group had a greater occurrence of wound infection (P=0.043), tendonitis, (P=0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the “gross motor” category (walking upstairs, bending over, walking 500 yards; P=0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after 1 year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries. PMID:27408765

  11. Minimal internal fixation augmented by small wire transfixion frames for high-energy tibial plateau fractures.

    PubMed

    Katsenis, Dimitris; Athanasiou, Vasilis; Vasilis, Athanasiou; Megas, Panayiotis; Panayiotis, Megas; Tyllianakis, Minos; Minos, Tillianakis; Lambiris, Elias

    2005-04-01

    To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.

  12. Stress corrosion cracking of an aluminum alloy used in external fixation devices.

    PubMed

    Cartner, Jacob L; Haggard, Warren O; Ong, Joo L; Bumgardner, Joel D

    2008-08-01

    Treatment for compound and/or comminuted fractures is frequently accomplished via external fixation. To achieve stability, the compositions of external fixators generally include aluminum alloy components due to their high strength-to-weight ratios. These alloys are particularly susceptible to corrosion in chloride environments. There have been several clinical cases of fixator failure in which corrosion was cited as a potential mechanism. The aim of this study was to evaluate the effects of physiological environments on the corrosion susceptibility of aluminum 7075-T6, since it is used in orthopedic external fixation devices. Electrochemical corrosion curves and alternate immersion stress corrosion cracking tests indicated aluminum 7075-T6 is susceptible to corrosive attack when placed in physiological environments. Pit initiated stress corrosion cracking was the primary form of alloy corrosion, and subsequent fracture, in this study. Anodization of the alloy provided a protective layer, but also caused a decrease in passivity ranges. These data suggest that once the anodization layer is disrupted, accelerated corrosion processes occur. (c) 2007 Wiley Periodicals, Inc.

  13. Limb salvage in Charcot foot and ankle osteomyelitis: combined use single stage/double stage of arthrodesis and external fixation.

    PubMed

    Dalla Paola, Luca; Brocco, Enrico; Ceccacci, Tanja; Ninkovic, Sasa; Sorgentone, Sara; Marinescu, Maria Grazia; Volpe, Antonio

    2009-11-01

    Charcot neuroarthropathy of the foot/ankle is a devastating complication of diabetes. Along with neuroarthropathy, osteomyelitis can occur which can result in amputation. This prospective study evaluated a limb salvage procedure as an alternative to amputation through surgical treatment of osteomyelitis of the midfoot or the ankle and stabilization with external fixation. Forty-five patients with Charcot arthropathy and osteomyelitis underwent debridement and attempted fusion with an external fixator. Chart and radiograph review was performed to assess the success of the fusion and eradication of infection. Out of 45 patients, 39 patients healed using emergent surgery to drain an acute manifestation of the infection while maintaining the fixation for an average of 25.7 weeks. Two patients were treated with intramedullary nail in a subsequent surgical procedure. In four patients, the infection could not be controlled, therefore a major amputation was carried out. For select patients, external fixation proved to be a reasonable alternative to below-knee amputation.

  14. [Curative effect analysis on closed reduction and external fixator under local anesthesia for the treatment of intertrochanteric fracture in elderly patients with high-risk].

    PubMed

    Wang, Zeng-ping; Liu, Lin; Xue, Wen; Zhou, Hui-ru; Song, Yu-xin; Cai, Li-yang; Cheng, Xian-tang; Qian, Yao-wen

    2016-06-01

    To explore clinical efficacy of closed reduction and external fixation under local anesthesia for the treatment of high-risk elderly patients with intertrochanteric fracture. From March 2013 to March 2015, 10 patients with intertrochanteric fractures treated with closing reduction and external fixator under local anesthesia were analyszed, including 4 males and 6 females, aged from 69 to 88 years old with an average of 75.2 years old. All fractures were caused by injury and classified to type I (5 cases), II (3 cases), and V (2 cases) according to Evans classification. According to American Society of Anesthesiologists (ASA), 6 cases were type III and 4 cases were type IV. Blood loss,operative time,hospital stays, postoperative complications, ambulation time and fracture healing time were observed, and Harris scoring were used to evaluate hip joint function. All patients were followed up from 3 to 23 months with an average of 13.1 months. One patient with chronic obstructive pulmonary disease died for non-operation reason at 4 months after operation, the other fractures were healed at stage I, the mean fracture healing time was 5.6 months. There were no coxa vara, lower limb venous thrombosis, loosen and remove of needle passage. The average operative time was 46 min, blood loss was (35.00 ± 8.46) ml without blood transfusion. One patient was occurred pulmonary infection and stent-tract infection on the 2 nd and 3 rd day after operation, and improved with active anti-infection and dressing change; the other patients gone to ground activity at 4.2 d after operation. The patients stayed hospital for 10.6 d on average. According to Harris scoring at final following-up, the total score was 83.42 ± 3.27, 3 cases obtained excellent results, 5 cases good and 1 case poor. Closed reduction and external fixation under local anesthesia in treating high-risk elderly patients with intertrochanteric fracture,which has advantages of shorter operative time, less blood loss, good recovery of postoperative function, is a safe, stable and economic method.

  15. [Treatment of pediatric distal femur fractures by external fixator combined with limited internal fixation].

    PubMed

    Wei, Sheng-wang; Shi, Zhan-ying; Hu, Ju-zheng; Wu, Hao

    2016-03-01

    To discuss the clinical effects of external fixator combined with limited internal fixation in the treatment of pediatric distal femur fractures. From January 2008 to June 2014, 17 children of distal femur fractures were treated by external fixator combined with limited internal fixation. There were 12 males and 5 females, aged from 6 to 13 years old with an average of 10.2 years, ranged in the course of disease from 1 h to 2 d. Preoperative diagnoses were confirmed by X-ray films in all children. There were 11 patients with supracondylar fracture , and 6 patients with intercondylar comminuted fracture. According to AO/ASIF classification, 9 fractures were type A1, 5 cases were type A2,and 3 cases were type C1. The intraoperative and postoperative complications, postoperative radiological examination, lower limbs length and motion of knee joints were observed. Knee joint function was assessed by KSS score. All the patients were followed up from 6 to 38 months with an average of 24.4 months. No nerve or blood vessel injury was found. One case complicated with the external fixation loosening, 2 cases with the infection of pin hole and 3 cases with the leg length discrepancy. Knee joint mobility and length measurement (compared with the contralateral), the average limited inflexion was 10 degrees (0 degrees to 20 degrees), the average limited straight was 4 degrees (0 degrees to 10), the average varus or valgus angle was 3 degrees (0 degrees to 5 degrees). KSS of the injured side was (96.4 +/- 5.0) points at final follow-up, 16 cases got excellent results and 1 good. All fractures obtained healing and no epiphyseal closed early was found. External fixator combined with limited internal fixation has advantages of simple operation, reliable fixation, early functional exercise in treating pediatric distal femurs fractures.

  16. Treatment of inherently unstable open or infected fractures by open wound management and external skeletal fixation.

    PubMed

    Ness, M G

    2006-02-01

    To assess the use of external skeletal fixation with open wound management for the treatment of inherently unstable open or infected fractures in dogs. A retrospective review of 10 cases. Fracture stabilisation and wound management required only a single anaesthetic, and despite the challenging nature of these injuries, the final outcome was acceptable or good in every case. However, minor complications associated with the fixator pins were quite common, and two dogs developed complications which required additional surgery. Open management of wounds, even when bone was exposed, proved to be an effective technique, and external skeletal fixators were usually effective at maintaining stability throughout an inevitably extended fracture healing period.

  17. Treatment of war injuries of the shoulder with external fixators.

    PubMed

    Davila, Slavko; Mikulić, Danko; Davila, Neda Jarza; Popović, Ljiljana; Zupancić, Bozidar

    2005-05-01

    In this retrospective study, 18 patients with war injuries of the shoulder were reviewed to evaluate the technical problems associated with external fixation and to analyze the incidence of infection and late functional results. The average patient age was 28.5 years. All patients were male. Thirteen patients had explosive wounds, whereas five wounds were caused by gunshot missiles. All injuries were extensive in terms of bone and soft tissue defects. Six patients presented with complex injuries involving neurovascular structures. Sixteen patients were treated with external fixation. Application of the proximal pins of the external fixator through the humeral head was possible in eight patients, the scapula served as the site of proximal fixation in four patients, only the clavicle was available for placement of pins in two patients, and both the scapula and the clavicle had to be pinned to achieve proximal stabilization in two patients. In two patients, fixation was not possible and early amputation was performed. Infection was eventually eradicated in all patients, allowing for adequate soft tissue coverage of the wounds. Analysis of functional results at an average of 6 years after the injury showed a considerable degree of functional deficit in most patients.

  18. A simple and inexpensive external fixator.

    PubMed

    Noor, M A

    1988-11-01

    A simple and inexpensive external fixator has been designed. It is constructed of galvanized iron pipe and mild steel bolts and nuts. It can easily be manufactured in a hospital workshop with a minimum of tools.

  19. Biomechanics of Two External Fixator Devices Used in Rat Femoral Fractures.

    PubMed

    Osagie-Clouard, Liza; Kaufmann, Joshua; Blunn, Gordon; Coathup, Melanie; Pendegrass, Catherine; Meeson, Richard; Briggs, Timothy; Moazen, Mehran

    2018-05-04

    The use of external fixators allows for the direct investigation of newly formed interfragmentary bone, and the radiographic evaluation of the fracture. We validated the results of a finite element model with the in vitro stiffness' of two widely used external fixator devices used for in vivo analysis of fracture healing in rat femoral fractures with differing construction (Ti alloy ExFix1 and PEEK ExFix2). Rat femoral fracture fixation was modelled using two external fixators. For both constructs an osteotomy of 2.75 mm was used, and offset maintained at 5 mm. Tufnol, served as standardized substitutes for rat femora. Constructs were loaded under axial compression and torsion. Overall axial and torsional stiffness were compared between the in vitro models and FE results. FE models were also used to compare the fracture movement and overall pattern of von Mises stress across the external fixators. In vitro axial stiffness of ExFix1 was 29.26 N/mm ± 3.83 compared to ExFix2 6.31 N/mm ± 0.67 (p* < 0.05). Torsional stiffness of ExFix1 was 47.5 Nmm/° ± 2.71 compared to ExFix2 at 19.1 Nmm/° ± 1.18 (p* < 0.05). FE results predicted similar comparative ratios between the ExFix1 and 2 as the in vitro studies. FE results predicted considerably larger interfragmentary motion in the ExFix2 comparing to ExFix1. We demonstrated significant differences in the stiffness' of the two external fixators as one would expect from such variable designs; yet, importantly we validated the utility of an FE model for the analysis and prediction of changes in fracture mechanics dependent on fixator choice. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Radial nerve injury following elbow external fixator: report of three cases and literature review.

    PubMed

    Trigo, Luis; Sarasquete, Juan; Noguera, Laura; Proubasta, Ignacio; Lamas, Claudia

    2017-07-01

    Radial nerve palsy is a rare but serious complication following elbow external fixation. Only 11 cases have been reported in the literature to date, but the incidence may be underreported. We present three new cases of this complication. We analyzed the three cases of radial palsy seen in our center following the application of an external fixator as treatment for complex elbow injuries. Mean patient age at surgery was 50 years. Two patients were female and one was male. In the three cases, the initial lesion was a posterior elbow dislocation, associated with a fracture of the radial shaft in one and a radial head fracture and coronoid fracture, respectively, in the other two. Due to persistent elbow instability, an external fixator was applied in all three cases. The fixator pins were introduced percutaneously in two cases and under direct vision in an open manner in the third case. Radial palsy was noted immediately postoperatively in all cases. It was permanent in two cases and temporary in the third. Radial nerve palsy after placement of an external elbow fixator was resolved in only 1 of our 3 cases and in 6 of the 11 cases in the literature to date. Although the event is rare, these alarming results highlight the need for recommendations to avoid this complication.

  1. Dynamic Distraction External Fixation for Contracture of the Metacarpophalangeal Joint.

    PubMed

    Seigerman, Daniel A; Tan, Virak

    2015-12-01

    Metacarpophalangeal (MP) joint contractures are common after traumatic injury, and can be difficult to manage. After surgical capsulectomy, it remains challenging to maintain motion that was obtained at the time of surgery. Our group uses a novel, prefabricated digital external fixator to provide both distraction, and motion therapy across the MP joint after surgical treatment of MP contracture. The purpose of this technique is to demonstrate the effectiveness of an adjunctive dynamic distraction external fixator for the maintenance of joint motion after surgical treatment of MP contractures of the border digits.

  2. Radiological evaluation of ankle arthrodesis with Ilizarov fixation compared to internal fixation.

    PubMed

    Morasiewicz, Piotr; Dejnek, Maciej; Urbański, Wiktor; Dragan, Szymon Łukasz; Kulej, Mirosław; Dragan, Szymon Feliks

    2017-07-01

    We asked whether the type of ankle joint arthrodesis stabilization will affect: (1) rate of union, (2) rate of adjacted-joint arthritis, (3) malalignment of the ankle joint. We retrospectively radiological studied 62 patients who underwent ankle arthrodesis with Ilizarov external fixator stabilization (group 1,n=29) or internal stabilization (group 2,n=33) from 2006 to 2015. Radiologic outcomes were mesure by: (1) rate of union, (2) rate of adjacent-joint arthritis, (3) malalignment of the ankle joint. The Levene's test,Mann-Whitney U test and Students t-test were used to the statistical analyses. Ankle fusion was achieved in 100% of patients treated with external fixation and in 88% with internal stabilization. Desired frontal plane alignment was achieved in 100% of patients with external fixation and 76% with internal stabilization. Desired sagittal plane alignment was achieved in 100% of external fixation and 85% of internal stabilization. A total of 14 (48.3%) patients from group 1 showed a radiographic evidence of pre-existing adjacent-joint OA. The radiographic evidence of pre-existing adjacent-joint OA was also found in 27(81.8%) subjects from group 2. Alterations of adjacent joints were also found on postoperative radiograms of 19 (65.5%) patients subjected to Ilizarov fixation and in all 33 patients from group 2. Ilizarov fixation of ankle arthrodesis is associated with lower prevalence of adjacent-joint OA and ankle joint misalignment,and with higher fusion rates than after internal fixation.Although achieving a complex ankle fusion is generally challenging,radiological outcomes after fixation with the Ilizarov apparatus are better than after internal stabilization. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Operative Cost Comparison: Plating Versus Intramedullary Fixation for Clavicle Fractures.

    PubMed

    Hanselman, Andrew E; Murphy, Timothy R; Bal, George K; McDonough, E Barry

    2016-09-01

    Although clavicle fractures often heal well with nonoperative management, current literature has shown improved outcomes with operative intervention for specific fracture patterns in specific patient types. The 2 most common methods of midshaft clavicle fracture fixation are intramedullary and plate devices. Through retrospective analysis, this study performed a direct cost comparison of these 2 types of fixation at a single institution over a 5-year period. Outcome measures included operative costs for initial surgery and any hardware removal surgeries. This study reviewed 154 patients (157 fractures), and of these, 99 had intramedullary fixation and 58 had plate fixation. A total of 80% (79 of 99) of intramedullary devices and 3% (2 of 58) of plates were removed. Average cost for initial intramedullary placement was $2955 (US dollars) less than that for initial plate placement (P<.001); average cost for removal was $1874 less than that for plate removal surgery (P=.2). Average total cost for all intramedullary surgeries was $1392 less than the average cost for all plating surgeries (P<.001). Average cost for all intramedullary surgeries requiring plate placement and removal was $653 less than the average cost for all plating surgeries that involved only placement (P=.04). Intramedullary fixation of clavicle fractures resulted in a statistically significant cost reduction compared with plate fixation, despite the incidence of more frequent removal surgeries. [Orthopedics.2016; 39(5):e877-e882.]. Copyright 2016, SLACK Incorporated.

  4. [Comparison study on locking compress plate external fixator and standard external fixator for treatment of tibial open fractures].

    PubMed

    Wu, Gang; Luo, Xiaozhong; Tan, Lun; Lin, Xu; Wu, Chao; Guo, Yong; Zhong, Zewei

    2013-11-01

    To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P > 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P > 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (Chi(2)=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 versus 13.0% and 0 versus 8.7%, P > 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (Chi(2)=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P < 0.05). The LCP external fixator can obtain reliable fixation in treating tibial open fracture, and has good patients' compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.

  5. [Pedicle flap transfer combined with external fixator to treat leg open fracture with soft tissue defect].

    PubMed

    Luo, Zhongchun; Lou, Hua; Jiang, Junwei; Song, Chunlin; Gong, Min; Wang, Yongcai

    2008-08-01

    To investigate the clinical results of treating leg open fracture with soft tissue defect by pedicle flap transfer in combination with external fixator. From May 2004 to June 2007, 12 cases of leg open fracture with soft tissue defect, 9 males and 3 females aged 18-75 years, were treated. Among them, 8 cases were caused by traffic accidents, 2 crush, 1 falling and 1 mechanical accident. According to the Gustilo Classification, there were 2 cases of type II, 5 of type IIIA and 5 of type IIIB. There were 2 cases of upper-tibia fracture, 3 of middle-tibia and 7 of middle-lower. The sizes of soft tissue defect ranged from 5 cm x 3 cm to 22 cm x 10 cm.The sizes of exposed bone ranged from 3 cm x 2 cm to 6 cm x 3 cm. The course of the disease was 1-12 hours. Fracture fixation was reached by external fixators or external fixators and limited internal fixation with Kirschner wire. The wounds with exposed tendons and bones were repaired by ipsilateral local rotation flap, sural neurocutaneous flap and saphenous nerve flap. The size of selected flap ranged from 5 cm x 4 cm to 18 cm x 12 cm. Granulation wounds were repaired by skin grafting or direct suture. All patients were followed up for 6 months to 2 years. All patients survived, among whom 2 with the wound edge infection and 1 with the distal necrosis were cured by changing the dressing, 8 with pin hole infection were treated by taking out the external fixator, 1 with nonunion received fracture healing after bone graft in comminuted fracture of lower tibia, 2 suffered delayed union in middle-lower tibia fracture. The ROM of ankle in 3 cases was mildly poor with surpass-joint fixation, with plantar extension of 0-10 degrees and plantar flexion of 10-30 degrees, while the others had plantar extension of 10-20 degrees and plantar flexion of 30-50 degrees. The method of pedicle flap transfer combined with external fixator is safe and effective for the leg open fracture with soft tissue defect.

  6. External fixation versus open reduction with locked volar plating for geriatric distal radius fractures.

    PubMed

    Lee, Daniel J; Elfar, John C

    2014-09-01

    The optimal management of displaced dorsal radius fractures (DRFs) in older patients remains an issue of debate. Bridging external fixation is a well-accepted treatment modality for severely comminuted DRFs, while open reduction and internal fixation with locked volar plating has emerged as a promising alternative in recent years. The current body of randomized trials supports the trend toward locked volar plating, as it allows for quicker improvement in subjective and functional outcomes. There is no clear evidence to suggest that one technique carries significantly less complications than the other. Locked volar plating should be considered in patients for whom an accelerated functional recovery would be advantageous. Otherwise, both external fixation and locked volar plating provide good long-term clinical outcomes.

  7. [Clinical application of percutaneous iliosacral screws combined with pubic ramus screws in Tile B pelvic fracture].

    PubMed

    Xu, Qi-Fei; Lin, Kui-Ran; Zhao, Dai-Jie; Zhang, Song-Qin; Feng, Sheng-Kai; Li, Chen

    2017-03-25

    To investigate the application and effect of minimally invasive percutaneous anterior pelvic pubic ramus screw fixation in Tile B fractures. A retrospective review was conducted on 56 patients with posterior pelvic ring injury combined with fractures of anterior pubic and ischiadic ramus treated between May 2010 and August 2015, including 31 males and 25 females with an average age of 36.8 years old ranging from 35 to 65 years old. Based on the Tile classification, there were 13 cases of Tile B1 type, 28 cases of Tile B2 type and 15 cases of Tile B3 type. Among them, 26 patients were treated with sacroiliac screws combined with external fixation (external fixator group) and the other 30 patients underwent sacroiliac screw fixation combined with anterior screw fixation (pubic ramus screw group). Postoperative complications, postoperative ambulation time, fracture healing, blood loss, Majeed pelvic function score and visual analogue scale(VAS) were compared between two groups. Fifty-four patients were followed up from 3 to 24 months with a mean of 12 months. There were no significant difference in the peri-operative bleeding and operation time between two groups( P >0.05). The postoperative activity time and fracture healing time of pubic ramus screw group were shorter than those of the external fixator group, the differences were statistically significant( P <0.05). The Majeed score, VAS score of pubic ramus screw group were higher than those of the external fixator group, the differences were statistically significant( P <0.05). The incidence of postoperative complications of pubic ramus screw was lower than that of the external fixator group, the difference was statistically significant ( P <0.05). Percutaneous iliosacral screws fixation combined with the pubic ramus screw is an effective and safty treatment method to the Tile B pelvic fracture. It has advantages of early ambulation, relief of the pain and few complications.

  8. The Cost-Effectiveness of Surgical Fixation of Distal Radial Fractures: A Computer Model-Based Evaluation of Three Operative Modalities.

    PubMed

    Rajan, Prashant V; Qudsi, Rameez A; Dyer, George S M; Losina, Elena

    2018-02-07

    There is no consensus on the optimal fixation method for patients who require a surgical procedure for distal radial fractures. We used cost-effectiveness analyses to determine which of 3 modalities offers the best value: closed reduction and percutaneous pinning, open reduction and internal fixation, or external fixation. We developed a Markov model that projected short-term and long-term health benefits and costs in patients undergoing a surgical procedure for a distal radial fracture. Simulations began at the patient age of 50 years and were run over the patient's lifetime. The analysis was conducted from health-care payer and societal perspectives. We estimated transition probabilities and quality-of-life values from the literature and determined costs from Medicare reimbursement schedules in 2016 U.S. dollars. Suboptimal postoperative outcomes were determined by rates of reduction loss (4% for closed reduction and percutaneous pinning, 1% for open reduction and internal fixation, and 11% for external fixation) and rates of orthopaedic complications. Procedural costs were $7,638 for closed reduction and percutaneous pinning, $10,170 for open reduction and internal fixation, and $9,886 for external fixation. Outputs were total costs and quality-adjusted life-years (QALYs), discounted at 3% per year. We considered willingness-to-pay thresholds of $50,000 and $100,000. We conducted deterministic and probabilistic sensitivity analyses to evaluate the impact of data uncertainty. From the health-care payer perspective, closed reduction and percutaneous pinning dominated (i.e., produced greater QALYs at lower costs than) open reduction and internal fixation and dominated external fixation. From the societal perspective, the incremental cost-effectiveness ratio for closed reduction and percutaneous pinning compared with open reduction and internal fixation was $21,058 per QALY and external fixation was dominated. In probabilistic sensitivity analysis, open reduction and internal fixation was cost-effective roughly 50% of the time compared with roughly 45% for closed reduction and percutaneous pinning. When considering data uncertainty, there is only a 5% to 10% difference in the frequency of probability combinations that find open reduction and internal fixation to be more cost-effective. The current degree of uncertainty in the data produces difficulty in distinguishing either strategy as being more cost-effective overall and thus it may be left to surgeon and patient shared decision-making. Economic Level III. See Instructions for Authors for a complete description of levels of evidence.

  9. Arthrodesis of the knee following failed arthroplasty.

    PubMed

    Van Rensch, P J H; Van de Pol, G J; Goosen, J H M; Wymenga, A B; De Man, F H R

    2014-08-01

    Primary stability in arthrodesis of the knee can be achieved by external fixation, intramedullary nailing or plate fixation. Each method has different features and results. We present a practical algorithm for arthrodesis of the knee following a failed (infected) arthroplasty, based on our own results and a literature review. Between 2004 and 2010, patients were included with an indication for arthrodesis after failed (revision) arthroplasty of the knee. Patients were analyzed with respect to indication, fusion method and bone contact. End-point was solid fusion. Twenty-six arthrodeses were performed. Eighteen patients were treated because of an infected arthroplasty. In total, ten external fixators, ten intramedullary nails and six plate fixations were applied; solid fusion was achieved in 3/10, 8/10 and 3/6, respectively. There is no definite answer as to which method is superior in performing an arthrodesis of the knee. Intramedullary nailing achieved the best fusion rates, but was used most in cases without--or cured--infection. Our data and the contemporary literature suggest that external fixation can be abandoned as standard fusion method, but can be of use following persisting infection. The Ilizarov circular external fixator, however, seems to render high fusion rates. Good patient selection and appropriate individual treatment are the key to a successful arthrodesis. Based upon these findings, a practical algorithm was developed.

  10. External fixation of "intertrochanteric" fractures.

    PubMed

    Gani, Naseem Ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool

    2009-10-10

    In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with "intertrochanteric" fractures remain unsuita ble for open reduction and internal fixation.The aim of this study was to analyze the results of external fixation of "intertrochanteric" fractures in high-risk geriatric patients in a developing country.The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58-90 years) with "intertrochanteric" fractures, in whom external fixation was performed, are reported.Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients.This study demonstrated that external fixation of "intertrochantric" fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country.

  11. Evidence of cartilage repair by joint distraction in a canine model of osteoarthritis.

    PubMed

    Wiegant, Karen; Intema, Femke; van Roermund, Peter M; Barten-van Rijbroek, Angelique D; Doornebal, Arie; Hazewinkel, Herman A W; Lafeber, Floris P J G; Mastbergen, Simon C

    2015-02-01

    Knee osteoarthritis (OA) is a degenerative joint disorder characterized by cartilage, bone, and synovial tissue changes that lead to pain and functional impairment. Joint distraction is a treatment that provides long-term improvement in pain and function accompanied by cartilage repair, as evaluated indirectly by imaging studies and measurement of biochemical markers. The purpose of this study was to evaluate cartilage tissue repair directly by histologic and biochemical assessments after joint distraction treatment. In 27 dogs, OA was induced in the right knee joint (groove model; surgical damage to the femoral cartilage). After 10 weeks of OA development, the animals were randomized to 1 of 3 groups. Two groups were fitted with an external fixator, which they wore for a subsequent 10 weeks (one group with and one without joint distraction), and the third group had no external fixation (OA control group). Pain/function was studied by force plate analysis. Cartilage integrity and chondrocyte activity of the surgically untouched tibial plateaus were analyzed 25 weeks after removal of the fixator. Changes in force plate analysis values between the different treatment groups were not conclusive. Features of OA were present in the OA control group, in contrast to the generally less severe damage after joint distraction. Those treated with joint distraction had lower macroscopic and histologic damage scores, higher proteoglycan content, better retention of newly formed proteoglycans, and less collagen damage. In the fixator group without distraction, similarly diminished joint damage was found, although it was less pronounced. Joint distraction as a treatment of experimentally induced OA results in cartilage repair activity, which corroborates the structural observations of cartilage repair indicated by surrogate markers in humans. Copyright © 2015 by the American College of Rheumatology.

  12. A Meta-Analysis for Postoperative Complications in Tibial Plafond Fracture: Open Reduction and Internal Fixation Versus Limited Internal Fixation Combined With External Fixator.

    PubMed

    Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang

    2015-01-01

    The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. [Indications for arthrodesis of the knee joint in modern orthopedics].

    PubMed

    Hart, R; Janecek, M; Bucek, P; Procházka, V; Visna, P

    2003-04-01

    Indication for arthrodesis of the knee joint is nowadays most frequently failure of a total endoprosthesis, usually septic. A less frequent indication is purulent gonitis, frequently after corticoid administration, the condition after a complicated intraarticular fracture with subsequent arthritis or oncological disease of the bones in the area of the knee joint. In the course of 2000 to 2002 at the authors' department 15 arthrodeses were implanted. In three cases the indication for arthrodesis was purulent gonitis, in three cases the condition after an open articular injury associated with infectious complications and in the remaining nine cases failure of an endoprosthesis of the knee, incl. seven caused by infection. The patients were three men and 12 women, mean age 64 years (30-75 years). For stabilization of the arthrodesis 9x external fixation was used, 5x plates and 1x intramedullary osteosynthesis. In all cases consolidation of the arthrodesis was achieved. In one case the external fixation had to be replaced by a system of two fixation devices and in one case correction of the axial position of the extremity was made. The presence of external fixation was perceived negatively in particular by female patients. Plate osteosynthesis and the use of external fixation devices are relatively quick, cheap and considerate methods of arthrodesis. External fixation must be used in acute virulent infections while plate osteosynthesis can be indicated in its absence. The characteristic of intramedullary fixation is similar, however special nails used for arthrodesis of the knee are several times more expensive than the previous types of stabilization. The advantage is the possibility to use a massive bone graft to fill the defect.

  14. Comparing fixation used for calcaneal displacement osteotomies: a look at removal rates and cost.

    PubMed

    Lucas, Douglas E; Simpson, G Alex; Philbin, Terrence M

    2015-02-01

    The calcaneal displacement osteotomy is a procedure frequently used by foot and ankle surgeons for hindfoot angular deformity. Traditional techniques use compression screw fixation that can result in prominent hardware. While the results of the procedure are generally good, a common concern is the development of plantar heel pain related to prominent hardware. The primary purpose of this study is to retrospectively compare clinical outcomes of 2 fixation methods for the osteotomy. Secondarily a cost analysis will compare implant costs to hardware removal costs. Records were reviewed for patients who had undergone a calcaneal displacement osteotomy fixated with either lag screw or a locked lateral compression plate (LLCP). Neuropathy, previous ipsilateral calcaneus surgery, heel pad trauma, or incomplete radiographic follow-up were exclusionary. Thirty-two patients (19.4%) required hardware removal from the screw fixation group compared to 1 (1.6%) of the LLCP group, which is significant (P < .05). Time to radiographic healing was not significantly different (P = .87). The screw fixation group required more follow-up visits over a longer period of time (P < .05). Implant cost was remarkably different with screw fixation costing on average $247.12, compared to the LLCP costing $1175.59. Although the LLCP cost was significantly higher, cost savings were identified when the cost of removal and removal rates were included. This study demonstrates that this device provides adequate stabilization for healing in equivalent time to screw fixation. The LLCP required decreased rates of hardware removal with fewer postoperative visits over a shorter period of time. Significant savings were demonstrated in the LLCP group despite the higher implant cost. Therapeutic, Level III, Retrospective Comparative Study. © 2014 The Author(s).

  15. Surgical correction of severe spinal deformities using a staged protocol of external and internal techniques.

    PubMed

    Prudnikova, Oksana G; Shchurova, Elena N

    2018-02-01

    There is high risk of neurologic complications in one-stage management of severe rigid spinal deformities in adolescents. Therefore, gradual spine stretching variants are applied. One of them is the use of external transpedicular fixation. Our aim was to retrospectively study the outcomes of gradual correction with an apparatus for external transpedicular fixation followed by internal fixation used for high-grade kyphoscoliosis in adolescents. Twenty five patients were reviewed (mean age, 15.1 ± 0.4 years). Correction was performed in two stages: 1) gradual controlled correction with the apparatus for external transpedicular fixation; and 2) internal posterior transpedicular fixation. Rigid deformities in eight patients required discapophysectomy. Clinical and radiographic study of the outcomes was conducted immediately after treatment and at a mean long-term period of 3.8 ± 0.4 years. Pain was evaluated using the visual analogue scale (VAS, 10 points). The Oswestry questionnaire (ODI scale) was used for functional assessment. Deformity correction with the external apparatus was 64.2 ± 4.6% in the main curve and 60.7 ± 3.7% in the compensatory one. It was 72.8 ± 4.1% and 66.2 ± 5.3% immediately after treatment and 70.8 ± 4.6% and 64.3 ± 4.2% at long term, respectively. Pain relieved by 33.2 ± 4.2% (p < 0.05) immediately after treatment and by 55.6 ± 2.8% (p < 0.05) at long term. ODI reduced by 30.2 ± 1.7% (p < 0.05) immediately after treatment and by 37.2 ± 1.6% (p < 0.05) at long term. The apparatus for external transpedicular fixation provides gradual controlled correction for high-grade kyphoscoliosis in adolescents. Transition to internal fixation preserves the correction achieved, and correction is maintained at long term.

  16. Reconstruction with distraction osteogenesis for juxta-articular nonunions with bone loss.

    PubMed

    Kabata, Tamon; Tsuchiya, Hiroyuki; Sakurakichi, Keisuke; Yamashiro, Teruhisa; Watanabe, Koji; Tomita, Kasuro

    2005-06-01

    Nonunions of a juxta-articular lesion with bone loss, which represent a challenging therapeutic problem, were treated using external fixation and distraction osteogenesis. Seven juxta-articular nonunions (five septic and two aseptic) were treated. The location of the nonunion was the distal femur in four patients, the proximal tibia in one patient, and the distal tibia in two patients. All of them were located within 5 cm from the affected joints. Preoperative limb shortening was present in six cases, averaging 2.9 cm (range, 1-7 cm). The reconstructive procedure consisted of refreshment of the nonunion site, deformity correction, stabilization by external fixation, and lengthening to eliminate leg length discrepancy or to fill the defect. Shortening-distraction was applied to six patients and bone transport to one patient for reconstruction. Intramedullary nailing to reduce the duration of external fixation was simultaneously performed in two cases. All the patients had at least 1 year of follow-up evaluation. Osseous union without angular deformity or leg length discrepancy greater than 1 cm was achieved in all patients. The mean amount of lengthening was 5.8 cm (range, 2.2-10.0 cm). The mean external fixation period was 219 days (range, 98-317 days), and the mean external fixation index was 34.4 days/cm (range, 24.5-47.6 days/cm). All patients reported excellent pain reduction. There were no recurrences of infection in five patients with prior history of osteomyelitis. The functional results were categorized as excellent in two, good in three, and fair in two. Despite the length of postoperative external fixation, distraction osteogenesis can be a valuable alternative for the treatment of juxta-articular nonunions.

  17. Method for fusing bone

    DOEpatents

    Mourant, J.R.; Anderson, G.D.; Bigio, I.J.; Johnson, T.M.

    1996-03-12

    The present invention is a method for joining hard tissue which includes chemically removing the mineral matrix from a thin layer of the surfaces to be joined, placing the two bones together, and heating the joint using electromagnetic radiation. The goal of the method is not to produce a full-strength weld of, for example, a cortical bone of the tibia, but rather to produce a weld of sufficient strength to hold the bone halves in registration while either external fixative devices are applied to stabilize the bone segments, or normal healing processes restore full strength to the tibia.

  18. Treatment with rhBMP-2 of extreme radial bone atrophy secondary to fracture management in an Italian Greyhound.

    PubMed

    Bernard, F; Furneaux, R; Adrega Da Silva, C; Bardet, J-F

    2008-01-01

    rhBMP-2 solution on a collagen sponge was placed along the diaphysis of an atrophicradius, which had a history of recurring fractures. Two months after rhBMP-2 treatment, new mineralized bone was present, which significantly increased the diameter of the radius and allowed the removal of the external skeletal fixator (ESF). Due to carpo-metacarpal joint compromise, a pancarpal arthrodesis was performed seven months later. At follow-up evaluation two years later the dog was only very mildly lame.

  19. Tibial lengthening using a humeral intramedullary nail combined with a single-plane external fixator for leg discrepancy in sequelae of poliomyelitis.

    PubMed

    Chen, Daoyun; Chen, Jianmin; Liu, Fanggang; Jiang, Yao

    2011-03-01

    The sequelae of poliomyelitis are the common causes of leg discrepancy. Tibial lengthening is an effective way to solve this problem but it is associated with a high rate of complications. In this study, we combined the use of humeral nail and external fixator in tibial lengthening with the purpose of reducing lengthening complications. Compared with the cases lengthened by a single-plane external fixator alone, this combined strategy was found to be beneficial in maintaining the tibial alignment. Therefore, it can be recommended as a good technique for tibial lengthening in patients with sequelae of poliomyelitis.

  20. Open fractures caused by high velocity missiles: the outcome of treatment of 39 fractures followed for 1-3 years.

    PubMed

    Khan, M A; Hussain, R; Khan, S H; Umar, M

    1997-11-01

    Between 1993 and 1995, thirty-three patients having 39 fractures caused by missiles fired from a high velocity rifle were reviewed retrospectively between 1 and 3 years after injury and the outcome of treatment assessed. Majority (33 out of 39) were Grade III. Union was achieved in 35 out of 39 fractures, there was deep infection and delayed union in one case each. Non-union occurred in three fractures. The fractures were stabilized using different techniques, but highest complication rate was seen with the use of the static external fixator. This was related to the severe nature of the injury as well as the inherent limitations of the external fixator. Revision of the external fixator with internal fixation after healing of the soft tissues seems to be the direction of the future.

  1. Quick-release medical tape

    PubMed Central

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M.

    2012-01-01

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive–skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes. PMID:23112196

  2. External fixation of “intertrochanteric” fractures

    PubMed Central

    Gani, Naseem ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool

    2009-01-01

    In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with “intertrochanteric” fractures remain unsuita ble for open reduction and internal fixation. The aim of this study was to analyze the results of external fixation of “intertrochanteric” fractures in high-risk geriatric patients in a developing country. The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58–90 years) with “intertrochanteric” fractures, in whom external fixation was performed, are reported. Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients. This study demonstrated that external fixation of “intertrochantric” fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country. PMID:21808680

  3. Advantages of external hybrid fixators for treating Schatzker V-VI tibial plateau fractures: A retrospective study of 40 cases.

    PubMed

    Gross, J-B; Gavanier, B; Belleville, R; Coudane, H; Mainard, D

    2017-10-01

    Proximal tibia fractures make up 1% of all fractures in adults. The fractures classified as Schatzker V and VI fractures can compromise knee structure and function. They are challenging to treat and often have complications. While plate fixation is the gold standard, the resulting infection rate has led us to favor external hybrid fixation. The aims of this study were to assess the radiographic and functional outcomes along with the complication rate when using this method and to compare them to historical plate fixation data. This was a retrospective study of 40 patients. The complications, quality of reduction, IKS, Lysholm and Rasmussen functional scores at the latest follow-up and factors affecting the functional outcome were evaluated. These parameters were compared to published results from plate fixation studies. The deep infection rate was 2.5%. The union rate was 80%. Satisfactory reduction was obtained in 70% of cases; however, 52% of patients had malunion. The mean IKS score was 73.74, the mean Rasmussen score was 22.85 and the mean Lysholm score was 75.53. Age, reduction at latest follow-up, mechanical axis and anteroposterior laxity had a significant effect on the functional outcome. Despite the malunion rate being higher than other studies, the functional outcomes were nearly identical based on the variables measured. There are several advantages associated with using a hybrid external fixator: shorter operative time, less bleeding, shorter hospital stays and lower infection rate. Hybrid external fixation is a reliable fracture fixation method that leads to satisfactory functional outcomes, while reducing the infection rate and allowing arthroplasty to be performed in the future if needed. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. PreFix™ external fixator used to treat a floating shoulder injury caused by gunshot wound.

    PubMed

    Vogels, J; Pommier, N; Cursolle, J-C; Belin, C; Tournier, C; Durandeau, A

    2014-10-01

    Open fractures of the shoulder are extremely rare, and their treatment is a major challenge for surgeons. Only cases encountered in military settings have been reported thus far. Such fractures are often the result of ballistic trauma, which causes extensive damage to both bony and soft tissues. Since these injuries are associated with a high risk of infection and the presence of comminuted fractures, external fixation is necessary for repair. Use of external fixators and revascularization techniques has reduced the number of cases requiring shoulder amputation or disarticulation. Injury to the proximal extremity of the humerus, acromion, and clavicle further complicates the treatment. No published studies have described the assembly of external fixators for fractures in the scapular region with significant bone loss. In addition, no cases have been described in civilian settings. However, with an increase in urban violence and the traffic of illegal arms, civilian surgeons are now encountering an increasing number of patients with these injuries. In this report, we not only present a rare case of floating shoulder injury in a civilian setting but also provide an overview of the existing treatment strategies for this type of trauma, with special focus on the use of external fixators in elective shoulder arthrodesis and on military cases. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  5. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  6. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  7. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  8. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  9. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  10. Internal versus external fixation of the anterior component in unstable fractures of the pelvic ring: pooled results from a systematic review.

    PubMed

    Wardle, B; Eslick, G D; Sunner, P

    2016-10-01

    Improving reduction of the pelvic ring improves long-term functional outcomes for patients. It has been demonstrated that posterior internal fixation is necessary to adequately control fractures to the posterior ring and there is evidence that supplementing this with fixation of the anterior ring improves stability. It is accepted that internal fixation provides greater stability than external fixation of the anterior ring but long-term differences in radiographic and functional outcomes have not yet been quantified. A search of electronic databases, reference lists and review articles from 1989 to 2015 yielded 18 studies (n = 884) that met our inclusion criteria. We included studies that discussed pelvic ring injuries in adults, reported functional or radiological outcomes or complications by anterior ring intervention and exceeded 14 patients. We excluded biomechanical and cadaver studies. Internal fixation of the anterior pelvic ring had better functional and radiographic outcomes. Residual displacement of >10 mm was less common with internal fixation (ER 0.12, 95 % CI 0.06-0.24) than external fixation (ER 0.31, 95 % CI 0.11-0.62). Unsatisfactory outcomes also occurred at a lower rate (ER 0.09, 95 % CI 0.03-0.22) compared to external fixation (ER 0.32, 95 % CI 0.18-0.50). Losses of reduction (ER 0.02, 95 % CI 0.01-0.04 versus ER 0.07, 95 % CI 0.02-0.21), malunions (ER 0.03, 95 % CI 0.01-0.08 versus ER 0.07, 95 % CI 0.02-0.21) and delayed/non-unions (ER 0.02, 95 % CI 0.01-0.05 versus ER 0.04, 95 % CI 0.02-0.07). Internal fixation of the anterior pelvic ring as supplementary fixation for unstable injuries to the pelvic ring appears to result in better radiographic and functional outcomes as well as fewer complications. However, data that separated outcomes and complications in relation to interventions of the anterior pelvic ring were limited. More studies looking specifically at outcomes in relation to the type of anterior ring intervention are needed.

  11. Operative Fixation Options for Elective and Diabetic Ankle Arthrodesis.

    PubMed

    Ramanujam, Crystal L; Stapleton, John J; Zgonis, Thomas

    2017-07-01

    Ankle arthrodesis remains one of the most definitive treatment options for end-stage arthritis, paralysis, posttraumatic and postinfectious conditions, failed total ankle arthroplasty, and severe deformities. The general aims of ankle arthrodesis are to decrease pain and instability, correct the accompanying deformity, and create a stable plantigrade foot. Several surgical approaches have been reported for ankle arthrodesis with internal fixation options. External fixation has also evolved for ankle arthrodesis in certain clinical scenarios. This article provides a comprehensive analysis of midterm to long-term outcomes for ankle arthrodesis using internal and/or external fixation each for elective and diabetic conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Improved Healing of Large, Osseous, Segmental Defects by Reverse Dynamization: Evaluation in a Sheep Model

    DTIC Science & Technology

    2014-10-01

    initiated. One such fixator has been tested on a cadaveric sheep tibia. In the unlocked, loose position, the axial stiffness of the tibia and fixator...suggested by our previous studies using rats. This aspect of the project is the present focus of attention, and additional cadaver legs will be tested...characterize external fixators). A 3 mm tibial defect was created in the leg of a cadaveric sheep, and stabilized with an experimental external

  13. Increased risk for complications following removal of hardware in patients with liver disease, pilon or pelvic fractures: A regression analysis.

    PubMed

    Brown, Bryan D; Steinert, Justin N; Stelzer, John W; Yoon, Richard S; Langford, Joshua R; Koval, Kenneth J

    2017-12-01

    Indications for removing orthopedic hardware on an elective basis varies widely. Although viewed as a relatively benign procedure, there is a lack of data regarding overall complication rates after fracture fixation. The purpose of this study is to determine the overall short-term complication rate for elective removal of orthopedic hardware after fracture fixation and to identify associated risk factors. Adult patients indicated for elective hardware removal after fracture fixation between July 2012 and July 2016 were screened for inclusion. Inclusion criteria included patients with hardware related pain and/or impaired cosmesis with complete medical and radiographic records and at least 3-month follow-up. Exclusion criteria were those patients indicated for hardware removal for a diagnosis of malunion, non-union, and/or infection. Data collected included patient age, gender, anatomic location of hardware removed, body mass index, ASA score, and comorbidities. Overall complications, as well as complications requiring revision surgery were recorded. Statistical analysis was performed with SPSS 20.0, and included univariate and multivariate regression analysis. 391 patients (418 procedures) were included for analysis. Overall complication rates were 8.4%, with a 3.6% revision surgery rate. Univariate regression analysis revealed that patients who had liver disease were at significant risk for complication (p=0.001) and revision surgery (p=0.036). Multivariate regression analysis showed that: 1) patients who had liver disease were at significant risk of overall complication (p=0.001) and revision surgery (p=0.039); 2) Removal of hardware following fixation for a pilon had significantly increased risk for complication (p=0.012), but not revision surgery (p=0.43); and 3) Removal of hardware for pelvic fixation had a significantly increased risk for revision surgery (p=0.017). Removal of hardware following fracture fixation is not a risk-free procedure. Patients with liver disease are at increased risk for complications, including increased risk for needing revision surgery following hardware removal. Patients having hardware removed following fixation for pilon fractures also are at increased risk for complication, although they may not require a return trip to the operating room. Finally, removal of pelvic hardware is associated with a higher return to the operating room. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Treatment of displaced intra-articular calcaneal fractures with triangular tube-to-bar external fixation: long-term clinical follow-up and radiographic analysis.

    PubMed

    Roukis, Thomas S; Wünschel, Markus; Lutz, Hans-Peter; Kirschner, Peter; Zgonis, Thomas

    2008-04-01

    Sixty-six feet (62 patients) with displaced intra-articular calcaneal fractures underwent manual reduction and distraction with the use of a triangular tube-to-bar external fixation device and were retrospectively reviewed at a minimum of 1-year post-operative. Final radiographic follow-up revealed complete consolidation in all fractures, maintenance of reduction, and limited degenerative osteoarthrosis about the subtalar joint. Our results indicate that with proper application and attention to detail, restoration of calcaneal morphology using triangular tube-to-bar external fixation should be considered a viable alternative in the treatment of displaced intra-articular fractures of the calcaneus.

  15. Temporary Stabilization with External Fixator in 'Tripolar' Configuration in Two Steps Treatment of Tibial Pilon Fractures.

    PubMed

    Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè

    2016-01-01

    The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation. Temporary stabilization with external fixator in 'tripolar' configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases.

  16. The benefits of hardware removal in patients with pain or discomfort after fracture healing of the ankle: a systematic review protocol.

    PubMed

    Thune, Alexandra; Hagelberg, Mårten; Nåsell, Hans; Sköldenberg, Olof

    2017-08-11

    For any orthopaedic surgeon working with trauma; ankle fractures are one of the most common injuries treated. The treatment of ankle fractures can be conservative, using external fixation, but more commonly the fractures are treated with open reduction and internal fixation. Residual pain and discomfort are common in patients after surgical treatment of fractures of the ankle. Sometimes it is difficult to determine whether the pain or discomfort is due to the implants left in situ or the primary injury itself. In many cases, the decision is made to remove the implants. Extraction of internal fixation material from the ankle is a common procedure in many orthopaedic clinics. There are no evidence-based guidelines or consensus regarding the effect of hardware removal from the ankle. The aim of this protocol is to describe the method that will be used to collect, describe and analyse the current evidence regarding hardware removal after fracture healing of the ankle. We will conduct a systematic review of studies that were published after 1967 regarding the benefits of hardware removal in patients with pain or discomfort after fracture healing of the ankle. Study selection will follow the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. We will make a predefined search strategy and use it in several databases. We will include both randomised controlled trials (RCTs) and non-RCT studies. We will use descriptive statistics to summarise the studies collected. If more than one RCT is collected then a meta-analysis will be conducted. The quality of evidence will be assessed using Grading of Recommendations Assessment, Development and Evaluation guidelines. No ethics approval is required as no primary data will be collected. Once complete, the results will be made available by peer-reviewed publication. PROSPERO registration number CRD42016039186. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Adjustable stiffness, external fixator for the rat femur osteotomy and segmental bone defect models.

    PubMed

    Glatt, Vaida; Matthys, Romano

    2014-10-09

    The mechanical environment around the healing of broken bone is very important as it determines the way the fracture will heal. Over the past decade there has been great clinical interest in improving bone healing by altering the mechanical environment through the fixation stability around the lesion. One constraint of preclinical animal research in this area is the lack of experimental control over the local mechanical environment within a large segmental defect as well as osteotomies as they heal. In this paper we report on the design and use of an external fixator to study the healing of large segmental bone defects or osteotomies. This device not only allows for controlled axial stiffness on the bone lesion as it heals, but it also enables the change of stiffness during the healing process in vivo. The conducted experiments have shown that the fixators were able to maintain a 5 mm femoral defect gap in rats in vivo during unrestricted cage activity for at least 8 weeks. Likewise, we observed no distortion or infections, including pin infections during the entire healing period. These results demonstrate that our newly developed external fixator was able to achieve reproducible and standardized stabilization, and the alteration of the mechanical environment of in vivo rat large bone defects and various size osteotomies. This confirms that the external fixation device is well suited for preclinical research investigations using a rat model in the field of bone regeneration and repair.

  18. Early Conversion of External Fixation to Interlocked Nailing in Open Fractures of Both Bone Leg Assisted with Vacuum Closure (VAC) - Final Outcome

    PubMed Central

    Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash

    2016-01-01

    Introduction Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. Aim To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. Materials and Methods In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Results Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian’s criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Conclusion Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA/B fractures without increasing the risk of infection. It gives better stability to fracture site and lessen the risk of implant failure. PMID:27042541

  19. Tibiotalar joint arthrodesis for the treatment of severe ankle joint degeneration secondary to rheumatoid arthritis.

    PubMed

    Caron, M; Kron, E; Saltrick, K R

    1999-04-01

    The technical aspects of fusion of the rheumatoid ankle do not deviate from those in the post-traumatic or osteoarthritic ankle. Screw fixation can usually be achieved, and rarely is fixation failure a problem in rheumatoid ankle arthrodesis. If fixation is difficult because of deformity or bone quality, external fixation or locking intramedullary nails should be used. The placement of cannulated screws and adequacy of screw fixation has not been a problem (Fig. 13). Screw fixation provides compression and prevents rotation. The surgeon, however, needs to be assured that no screws invade the subtalar joint and that all threads are beyond the arthrodesis site. A washer may be necessary for further stability if this screw is not inserted at too great an angle. The authors have found that troughing out of the cortical surface of the tibia with a power bur aids in screw insertion. Not only does the trough act as a countersink, but it also provides a path for screw insertion and prevents palpable screw irritation. Malalignment is unforgiving. The foot must be placed neutral to dorsiflexion and plantarflexion. Equinus positioning places added stress on the tibia and a back-knee gait occurs. Approximately 5 degrees of valgus is recommended, and varus positioning is unforgiving. Internal and external rotation is determined by the position of the contralateral extremity. Nonunion does not seem to be a problem with rigid internal fixation to any greater degree in patients with RA. Despite this, patients may continue to have pain despite solid fusion, which can be caused by incomplete correction of deformity, painful internal fixation, or adjacent joint pathology. Additionally, patients may experience supramalleolar pain above the fusion site consistent with tibial stress fracture, which is more common if the subtalar or midtarsal joint is rigid or if the patient is obese. A rocker sole shoe with impact-absorbing soles used after brief periods of guarded mobilization in a removable walking cast alleviates this stress on the tibia. Neurovascular insult can be avoided with careful dissection direct to bone, incisions placed in nerve-free zones, and avoidance of plunging deep posteriorly-medially and anteriorly when dissecting and resecting surfaces. Arthrodesis of the tibiotalar joint in the patient with RA should be performed to relieve severe pain caused by advanced arthrosis. Achieving a solid arthrodesis does not seem to be a problem and provides the patient with pain relief; however, marked improvement in patient function and level of activity remains limited by the nature of RA and adjacent joint involvement.

  20. Perioperative management of external fixation in staged protocols: an international survey.

    PubMed

    Hodel, Sandro; Link, Björn-Christian; Babst, Reto; Mallee, W H; Posso, Philippe; Beeres, Frank J P

    2018-05-01

    Despite the frequent use of external fixation, various regimes of antibiotic prophylaxis, surgical technique and postoperative pin care exist and underline the lack of current evidence. The aim of the study was to assess the variability or consensus in perioperative protocols to prevent implant-associated infections for temporary external fixation in closed fractures of the extremities. A 26-question survey was sent to 170 members of the Traumaplatform. The survey included questions concerning demographics, level of training, type of training and perioperative protocols as: antibiotic prophylaxis, intraoperative management, disinfection and postoperative pin site care. All responses were statistically analysed, and intraoperative measures rated on a 5-point Likert scale. The responses of fifty orthopaedic trauma and general surgeons (response rate, 29.4%) were analysed. The level of experience was more than 5 years in 92% (n = 46) with up to 50 closed fractures of the extremities annually treated with external fixation in 80% (n = 40). Highest consensus could be identified in the following perioperative measures: preoperative antibiotic prophylaxis with a second-generation cephalosporin (86%, n = 43), changing gloves if manipulation of the external fixator is necessary during surgery (86%, n = 43; 4.12 points on the Likert scale), avoid overlapping of the pin sites with the definitive implant site (94%, n = 47; 4.12 points on the Likert scale) and soft tissue protection with a drill sleeve (83.6%, n = 41). Our survey could identify some general principles, which were rated as important by a majority of the respondents. Futures studies' focus should elucidate the role of perioperative antibiotics and different disinfection protocols on implant-associated infections after temporary external fixation in staged protocols. This study provides Level IV evidence according to Oxford centre for evidence-based medicine.

  1. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation

    PubMed Central

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-01-01

    Abstract The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation. Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups. The mean follow-up time was 18.6 months (range: 5–24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5–9 months) and 6.0 months (range: 5–8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°–150°) and 135° (range: 100°–160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05). External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation. PMID:29019890

  2. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation.

    PubMed

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-10-01

    The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5-9 months) and 6.0 months (range: 5-8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°-150°) and 135° (range: 100°-160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.

  3. Method for fusing bone

    DOEpatents

    Mourant, Judith R.; Anderson, Gerhard D.; Bigio, Irving J.; Johnson, Tamara M.

    1996-01-01

    Method for fusing bone. The present invention is a method for joining hard tissue which includes chemically removing the mineral matrix from a thin layer of the surfaces to be joined, placing the two bones together, and heating the joint using electromagnetic radiation. The goal of the method is not to produce a full-strength weld of, for example, a cortical bone of the tibia, but rather to produce a weld of sufficient strength to hold the bone halves in registration while either external fixative devices are applied to stabilize the bone segments, or normal healing processes restore full strength to the tibia.

  4. Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction.

    PubMed

    Huish, Eric G; Coury, John G; Ibrahim, Mohamed A; Trzeciak, Marc A

    2017-04-01

    The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of -0.3 mm (-2.1 to 3.1 mm), and volar tilt of 7.9° (-3° to 15°). One patient had intra-articular step-off greater than 2 mm. Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.

  5. Fixator-assisted medial tibial plateau elevation to treat severe Blount's disease: outcomes at maturity.

    PubMed

    Fitoussi, F; Ilharreborde, B; Lefevre, Y; Souchet, P; Presedo, A; Mazda, K; Penneçot, G F

    2011-04-01

    Severe forms of Blount's disease may be associated with medial tibial plateau (MTP) depression. Management should then take account of joint congruence, laxity, limb axis, torsional abnomality, leg length discrepancy (LLD) and eventual recurrence history. Eight knees (six patients) were managed in a single step comprising MTP elevation osteotomy, lateral epiphysiodesis and proximal tibia osteotomy to correct varus and rotational deformity. Fixation was achieved using an Ilizarov external fixator. Mean age was 10.5 years. Mean hip-knee-ankle (HKA) angle was 151°; distal femoral varus, 94°; metaphyseal-diaphyseal angle (MDA), 27°; and angle of depression of the medial tibial plateau (ADMTP), 42°. Predicted residual proximal tibial growth was 2.6 cm. At a mean 48 months' follow-up, results were good in six cases, medium in one and poor (due to incomplete lateral epiphysiodesis) in one. Mean lateral tibial torsion was 9° and final LLD 11 mm. Weight-bearing was resumed at 2 months, and the fixator was removed at 5.5 months postoperatively. At end of follow-up, mean HKA angle was 179.6°, MDA 7.3° and ADMTP 5.4°. This technically demanding procedure gave satisfactory results in terms of axes and congruence; longer term assessment remains needed. Level IV. Retrospective study. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  6. No Higher Risk of CRPS After External Fixation of Distal Radial Fractures - Subgroup Analysis Under Randomised Vitamin C Prophylaxis.

    PubMed

    Zollinger, Paul E; Kreis, Robert W; van der Meulen, Hub G; van der Elst, Maarten; Breederveld, Roelf S; Tuinebreijer, Wim E

    2010-02-17

    Operative and conservative treatment of wrist fractures might lead to complex regional pain syndrome (CRPS) type I.In our multicenter dose response study in which patients with distal radial fractures were randomly allocated to placebo or vitamin C in a daily dose of 200mg, 500mg or 1500mg during 50 days, an operated subgroup was analyzed.48 (of 427) fractures) were operated (11.2%). Twenty-nine patients (60%) were treated with external fixation, 14 patients (29%) with K-wiring according to Kapandji and five patients (10%) with internal plate fixation. The 379 remaining patients were treated with a plaster.In the operated group of patients who received vitamin C no CRPS (0/37) was seen in comparison with one case of CRPS (Kapandji technique) in the operated group who received placebo (1/11 = 9%, p=.23). There was no CRPS after external fixation.In the conservatively treated group 17 cases of CRPS (17/379 = 4.5%) occurred in comparison with one in case of CRPS in the operated group (1/48 = 2.1%, p=.71).External fixation doesn't necessarily lead to a higher incidence of CRPS in distal radial fractures. Vitamin C may also play a role in this. This subgroup analysis in operated distal radial fractures showed no CRPS occurrence with vitamin C prophylaxis.

  7. Temporary Stabilization with External Fixator in ‘Tripolar’ Configuration in Two Steps Treatment of Tibial Pilon Fractures

    PubMed Central

    Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè

    2016-01-01

    Background: The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. Methods: We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. Results: We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation Conclusion: Temporary stabilization with external fixator in ‘tripolar’ configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases. PMID:27123151

  8. Monoaxial external fixation of the calcaneus: An anatomical study assessing the safety of monoaxial pin insertion.

    PubMed

    Thomson, Callum M; Esparon, Tom; Rea, Paul M; Jamal, Bilal

    2016-10-01

    The use of external fixation for intra-articular calcaneal fractures is increasing in popularity. Studies have shown fine wire and monoaxial external fixation to be a viable surgical alternative to more invasive methods of open reduction and internal fixation of the calcaneus. However, there is an absence of literature that quantifies the risk of pin insertion for monoaxial fixation. This study aimed to determine the safety of inserting monoaxial pins within the calcaneus to house the Orthofix Calcaneal Mini-Fixator. Five formalin embalmed cadaveric ankle and lower leg specimens were inserted with six monoaxial pins. Careful dissection then revealed the presence of the tendons of peroneus longus and brevis, the sural nerve and the small saphenous vein in relation to these pins. Measurements from each pin to each of these structures were made as the structures transected lines drawn from each pin to two palpable bony landmarks: the inferior tip of the lateral malleolus and the posterosuperior calcaneus. In doing this, the risk posed by each pin could be evaluated. We found that two particular pins, those used to hold the articular surface of the subtalar joint in a reduced position, posed a larger risk of injury to surrounding structures than the remaining pins. These findings therefore suggest that monoaxial fixation of the calcaneus using a six pin approach is a relatively safe method of rectifying calcaneal fractures and thus may serve as a welcome alternative to other methods of calcaneal fixation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Salter-Harris type II metacarpal and metatarsal fracture in three foals. Treatment by minimally-invasive lag screw osteosynthesis combined with external coaptation.

    PubMed

    Klopfenstein Bregger, Micaël D; Fürst, Anton E; Kircher, Patrick R; Kluge, Katharina; Kummer, Martin

    2016-05-18

    To describe minimally-invasive lag screw osteosynthesis combined with external coaptation for the treatment of Salter-Harris type II third metacarpal and third metatarsal bone fractures. Three foals aged two weeks to four months with a Salter-Harris type II third metacarpal or third metatarsal fracture. Surgery was carried out under general anaesthesia in lateral recumbency. After fracture reduction, the metaphyseal fragment was stabilized with two cortical screws placed in lag fashion under fluoroscopic control. A cast was applied for at least two weeks. All foals had a good outcome with complete fracture healing and return to complete soundness without any angular limb deformity. All foals had moderate transient digital hyperextension after cast removal. Internal fixation of Salter-Harris type II third metacarpal or third metatarsal fractures with two cortical screws in lag fashion, combined with external coaptation provided good stabilization and preserved the longitudinal growth potential of the injured physis.

  10. Comparison of Risk of Carpal Tunnel Syndrome in Patients with Distal Radius Fractures After 7 Treatments

    PubMed Central

    Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei

    2015-01-01

    Background To compare risk of carpal tunnel syndrome (CTS) in distal radius fracture (DRF) patients after 7 treatments using bridging external fixation (BrEF), non-bridging external fixation (non-BrEF), plaster fixation, K-wire fixation, dorsal plating fixation, volar plating fixation, and dorsal and volar plating by performing a network meta-analysis. Material/Methods An exhaustive search of electronic databases identified randomized controlled trails (RCTs) closely related to our study topic. The published articles were screened, based on predefined inclusion and exclusion criteria, to select high-quality studies for the present network meta-analysis. Data extracted from the selected studies were analyzed using STATA version 12.0 software. Results The literature search and selection process identified 12 eligible RCTs that contained a total of 1370 DRF patients (394 patients with BrEF, 377 patients with non-BrEF, 89 patients with K-wire fixation, 192 patients with plaster fixation, 42 patients with dorsal plating fixation, 152 patients with volar plating fixation, and 124 patients with dorsal and volar plating fixation). Our network meta-analysis results demonstrated no significant differences in CTS risk among the 7 treatments (P>0.05). The value of surface under the cumulative ranking curve (SUCRA), however, suggested that dorsal plating fixation is the optimal treatment, with the lowest risk of CTS in DRF patients (dorsal plating fixation: 89.2%; dorsal and volar plating: 57.8%; plaster fixation: 50.9%; non-BrEF: 50.6%; volar plating fixation: 39.6%; BrEF: 38.4%; K-wire fixation: 23.6%). Conclusions Our network meta-analysis provides evidence that dorsal plating fixation significantly decreases the risk of CTS and could be the method of choice in DRF patients. PMID:26391617

  11. Syndesmotic fixation in supination-external rotation ankle fractures: a prospective randomized study.

    PubMed

    Pakarinen, Harri J; Flinkkilä, Tapio E; Ohtonen, Pasi P; Hyvönen, Pekka H; Lakovaara, Martti T; Leppilahti, Juhana I; Ristiniemi, Jukka Y

    2011-12-01

    This study was designed to assess whether transfixion of an unstable syndesmosis is necessary in supination-external rotation (Lauge-Hansen SE/Weber B)-type ankle fractures. A prospective study of 140 patients with unilateral Lauge-Hansen supination-external rotation type 4 ankle fractures was done. After bony fixation, the 7.5-Nm standardized external rotation (ER) stress test for both ankles was performed under fluoroscopy. A positive stress examination was defined as a difference of more than 2 mm side-to-side in the tibiotalar or tibiofibular clear spaces on mortise radiographs. If the stress test was positive, the patient was randomized to either syndesmotic transfixion with 3.5-mm tricortical screws or no syndesmotic fixation. Clinical outcome was assessed using the Olerud-Molander scoring system, RAND 36-Item Health Survey, and Visual Analogue Scale (VAS) to measure pain and function after a minimum 1-year of followup. Twenty four (17%) of 140 patients had positive standardized 7.5-Nm ER stress tests after malleolar fixation. The stress view was positive three times on tibiotalar clear space, seven on tibiofibular clear space, and 14 times on both tibiotalar and tibiofibular clear spaces. There was no significant difference between the two randomization groups with regards to Olerud-Molander functional score, VAS scale measuring pain and function, or RAND 36-Item Health Survey pain or physical function at 1 year. Relevant syndesmotic injuries are rare in supination-external rotation ankle fractures, and syndesmotic transfixion with a screw did not influence the functional outcome or pain after the 1-year followup compared with no fixation.

  12. Pearls and pitfalls of deformity correction and limb lengthening via monolateral external fixation.

    PubMed Central

    Noonan, K. J.; Price, C. T.

    1996-01-01

    In conclusion, monolateral external fixation can be effectively utilized in the management of limb length discrepancy and angular deformity. This manuscript outlines the pertinent theory, application and problems important in these cases. When faced with specific congenital conditions the surgeon is encouraged to reference relevant literature that is more focused than the current paper. PMID:9129275

  13. Coupled external fixator and skin flap transposition for treatment of exposed and nonunion bone.

    PubMed

    Zhao, Yong-gang; Ding, Jing; Wang, Neng

    2011-02-01

    To discuss the effect of coupled external fixator and skin flap transposition on exposed and nonunion bones. The data of 12 cases of infected nonunion and exposed bone following open fracture treated in our hospital during the period of March 1998 to June 2008 were analysed. There were 10 male patients, 2 female patients, whose age were between 19-52 years and averaged 28 years. There were 10 tibial fractures and 2 femoral fractures. The course of diseases lasted for 12-39 months with the mean period of 19 months. All the cases were treated by the coupled external fixator and skin flap transposition. Primary healing were achieved in 10 cases and delayed healing in 2 cases in whom the tibia was exposed due to soft tissue defect and hence local flap transposition was performed. All the 12 cases had bony union within 6-12 months after operation with the average time of 8 months. They were followed up for 1-3 years and all fractures healed up with good function and no infection recurrence. The coupled external fixator and skin flap transposition therapy have shown optimal effects on treating infected, exposed and nonunion bones.

  14. Knee arthrodesis with circular external fixation.

    PubMed

    Garberina, M J; Fitch, R D; Hoffmann, E D; Hardaker, W T; Vail, T P; Scully, S P

    2001-01-01

    Knee arthrodesis can enable limb salvage in patients with disability secondary to trauma, infected total knee arthroplasty, pyarthrosis, and other complications. Historically, intramedullary nailing has resulted in the highest overall knee fusion rates. However, intramedullary nailing is relatively contraindicated in the presence of active infection. Nineteen patients who underwent knee arthrodesis with circular external fixation were studied retrospectively. Postoperative radiographs were evaluated for evidence of bony fusion, which was defined as trabecular bridging between the femur and tibia. Patients were interviewed and graded using the functional assessment portion of the Knee Society clinical rating system. Fusion was successful in 13 of 19 (68%) patients. Overall, patients spent an average of 4 months 8 days wearing the circular external fixator. Average time to radiographic and clinical evidence of arthrodesis (defined as lack of motion across the fusion site) was 4 months 18 days. No patient with successful fusion considered himself or herself housebound. All but one of these patients require some form of assistive device for ambulation. Complications occurred in 16 of 19 (84%) patients overall. Superficial pin tract infection (55%) and nonunion (32%) were the most common. Circular external fixation is an effective method for obtaining knee arthrodesis in patients who are not good candidates for intramedullary nailing.

  15. Acute Pelvic Fractures: II. Principles of Management.

    PubMed

    Tile

    1996-05-01

    The past two decades have seen many advances in pelvic-trauma surgery. Provisional fixation of unstable pelvic-ring disruptions and open-book fractures with a pelvic clamp or an external frame with a supracondylar pin has proved markedly beneficial in the resuscitative phase of management. In the completely unstable pelvis, external clamps and frames can act only as provisional fixation and should be combined with skeletal traction. The traction pin is usually used only until a definitive form of stabilization can be applied to keep the pelvic ring in a reduced position. If the patient is too ill to allow operative intervention, the traction pin can remain in place with the external frame as definitive treatment. Symphyseal disruptions and medial ramus fractures should be plated at the time of laparotomy. Lateral ramus fractures can usually be controlled with external frames. A role has been suggested for percutaneous retrograde fixation of the superior pubic ramus; however, the benefits to be gained may not be enough to outweigh the serious risks of penetrating the hip, and this technique should therefore be used only by surgeons trained in its performance. The techniques for posterior fixation are becoming more standardized, but all still carry significant risks, especially to neurologic structures.

  16. Comparison of intramedullary nailing and external fixation knee arthrodesis for the infected knee replacement.

    PubMed

    Mabry, Tad M; Jacofsky, David J; Haidukewych, George J; Hanssen, Arlen D

    2007-11-01

    We analyzed knee arthrodesis for the infected total knee replacement (TKR) using two different fixation techniques. Patients undergoing knee arthrodesis for infected TKR were identified and rates of successful fusion and recurrence of infection were compared using Cox proportional hazard models. Eighty-five consecutive patients who underwent knee arthrodesis were followed until union, nonunion, amputation, or death. External fixation achieved successful fusion in 41 of 61 patients and was associated with a 4.9% rate of deep infection. Fusion was successful in 23 of 24 patients with intramedullary (IM) nailing and was associated with an 8.3% rate of deep infection. We observed similar fusion and infection rates with the two techniques. Thirty-four patients (40%) had complications. Knee arthrodesis remains a reasonable salvage alternative for the difficult infected TKR. Complication rates are high irrespective of the technique, and one must consider the risks of both nonunion and infection when choosing the fixation method in this setting. IM nailing appears to have a higher rate of successful union but a higher risk of recurrent infection when compared with external fixation knee arthrodesis. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  17. Changes in the syndesmotic reduction after syndesmotic screw fixation for ankle malleolar fractures: One-year longitudinal evaluations using computer tomography.

    PubMed

    Endo, Jun; Yamaguchi, Satoshi; Saito, Masahiko; Morikawa, Tsuguo; Akagi, Ryuichiro; Sasho, Takahisa

    2016-10-01

    To evaluate time-dependent changes in the syndesmotic reduction after syndesmotic screw fixation and one year after screw removal for ankle malleolar fractures, and to assess whether the incidence of syndesmotic malreduction changes depending on the measurement method. We assessed twenty patients who underwent syndesmotic screw fixation for ankle fractures. The syndesmotic screws were removed after six weeks of the fracture surgery. Syndesmotic reduction was assessed within two weeks of the fracture surgery and one year after the screw removal using the axial computer tomographic images. Side-to-side differences in the anterior and posterior tibiofibular distances, anteroposterior fibular translation, and fibular rotation were measured. The mean anterior tibiofibular distance was 0.7mm after syndesmotic fixation. It increased to 1.9mm at one year after screw removal (p=0.002). After syndesmotic fixation, four ankles had malreduction of the anterior tibiofibular distance, including three ankles with widening and one with overtightening. At one year, eight ankles had malreduction, all of whom had widening. The other measurement values did not change over time (0.1mm vs. 0.6mm for the posterior tibiofibular distance, 0.2mm vs. 0.3mm for the anteroposterior fibular translation, and 0.7° vs. 0° for the fibular rotation). The incidences of malreduction were significantly different depending on the definition of malreduction, ranging from 10% to 50% after syndesmotic fixation (p=0.01) and from 20% to 60% at one year after screw removal (p=0.02). The anterior tibiofibular distance widened after one year of syndesmotic screw removal. The incidence of malreduction varied depending on the measurement method. Copyright © 2016. Published by Elsevier Ltd.

  18. Biomechanical characteristics of fixation methods for floating pubic symphysis.

    PubMed

    Song, Wenhao; Zhou, Dongsheng; He, Yu

    2017-03-07

    Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.

  19. Chronic elbow dislocation: a rare complication of tennis elbow surgery. Successful treatment by open reduction and external fixator.

    PubMed

    Degreef, I; De Smet, L

    2007-06-01

    A case is presented of chronic dislocation of the elbow after tennis elbow surgery combined with posterior interosseous nerve (PIN) release. An open reduction with repair of the collateral ligaments was performed. Postoperative rehabilitation involved the use of an articulated external fixator and there was a successful outcome. Possible causes of the dislocation are discussed.

  20. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.

    PubMed

    Kim, Joon-Woo; Oh, Chang-Wug; Oh, Jong-Keon; Kyung, Hee-Soo; Park, Kyeong-Hyeon; Kim, Hee-June; Jung, Jae-Wook; Jung, Young-Soo

    2017-06-01

    High-energy proximal tibial fractures often accompany compartment syndrome and are usually treated by fasciotomy with external fixation followed by secondary plating. However, the initial soft tissue injury may affect bony union, the fasciotomy incision or external fixator pin sites may lead to postoperative wound infections, and the staged procedure itself may adversely affect lower limb function. We assess the results of staged minimally invasive plate osteosynthesis (MIPO) for proximal tibial fractures with acute compartment syndrome. Twenty-eight patients with proximal tibial fractures accompanied by acute compartment syndrome who underwent staged MIPO and had a minimum of 12 months follow-up were enrolled. According to the AO/OTA classification, 6 were 41-A, 15 were 41-C, 2 were 42-A and 5 were 42-C fractures; this included 6 cases of open fractures. Immediate fasciotomy was performed once compartment syndrome was diagnosed and stabilization of the fracture followed using external fixation. After the soft tissue condition normalized, internal conversion with MIPO was done on an average of 37 days (range, 9-158) after index trauma. At the time of internal conversion, the external fixator pin site grades were 0 in 3 cases, 1 in 12 cases, 2 in 10 cases and 3 in 3 cases, as described by Dahl. Radiographic assessment of bony union and alignment and a functional assessment using the Knee Society Score and American Orthopedic Foot and Ankle Society (AOFAS) score were carried out. Twenty-six cases achieved primary bony union at an average of 18.5 weeks. Two cases of nonunion healed after autogenous bone grafting. The mean Knee Society Score and the AOFAS score were 95 and 95.3 respectively, at last follow-up. Complications included 1 case of osteomyelitis in a patient with a grade IIIC open fracture and 1 case of malunion caused by delayed MIPO due to poor wound conditions. Duration of external fixation and the external fixator pin site grade were not related to the occurrence of infection. Staged MIPO for proximal tibial fractures with acute compartment syndrome may achieve satisfactory bony union and functional results, while decreasing deep infections and soft tissue complications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. [Manipulative reduction and plaster external fixation for the treatment of the scaphoid fracture and perilunate dislocation].

    PubMed

    Zhang, Xin; Wei, Qiang; Ji, Fang; Tong, Da-Ke; Tang, Hao; Zhang, Hao; Yu, Jin-Guo; Yang, Ji-Dong; Cui, Rui; Huo, Ning-Ning

    2018-05-25

    To investigate the efficacy and complications of manual reduction and external fixation for the treatment of scaphoid fractures and perilunate dislocations. From January 2009 to January 2013, 43 patients suffered from scaphoid fractures and perilunate dislocations were retrospective analyzed. Among them, 17 cases were treated with manipulative reduction and plaster external fixation as conservation group including 10 males and 7 females, the other 26 cases were treated with application of surgical as operation group including 15 males and 11 females. The clinical effects were assessed by Cooney function score, radiological analysis and observation of complications. All patients were followed up for(45.00±8.72) months ranging from 36 to 60 months. At the final follow-up, the Cooney score of wrist function was 88.53±4.24 in conservation group and 89.58±4.59in operation group( t= 0.455, P >0.05). During the follow-up, 4 patients were found scaphoid avascular necrosis in the imaging performance in the conservation group(χ²=4.32, P <0.05). The difference of other complications between two groups was not statistically significant( P >0.05). For patients suffered from the scaphoid fractures and perilunate dislocation, the early manipulative reduction and plaster external fixation after injury as soon as possible is necessary. Maintaining a satisfactory reduction and reliable fixation at the same time can lead to good treatment effect and there's no weakness compared to surgical treatment. But there was an increase in danger of complications. The key of conservative treatment lies in early diagnosis and maintenance of reduction, reliable fixation, and timely and appropriate functional exercise. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  2. Bladder incarceration following anterior pelvic infix of a traumatic pubic symphysis diastasis treated with immediate open reduction and internal fixation.

    PubMed

    Jain, Mantu; Nanda, Saurav Narayan; Mohapatra, Soumya Shrikanta; Samal, Barada Prasanna

    2017-08-01

    Stabilization after a pelvic fracture can be accomplished using multiple techniques. The anterior external fixator has been traditionally used in variety of unstable pelvis either singly or in combination of posterior screws. These devices are cumbersome and restrict side turning and sitting particularly in obese patients. An alternative, anterior subcutaneous pelvic internal fixation technique (ASPIF) was developed which is well tolerated by patients for mobility and comfort and biomechanically more stable construct Complications of this construct included irritation of the lateral femoral cutaneous nerve, femoral nerve palsy &heterotypic ossification with reduced rates of infections and aseptic loosening as compared to external fixator. Bladder incarceration following treatment has never been reported and we encountered such a problem during management which we want to highlight.

  3. Acute Management of the Traumatically Injured Pelvis.

    PubMed

    Skitch, Steven; Engels, Paul T

    2018-02-01

    Severe pelvic trauma is a challenging condition. The pelvis can create multifocal hemorrhage that is not easily compressible nor managed by traditional surgical methods such as tying off a blood vessel or removing an organ. Its treatment often requires reapproximation of bony structures, damage control resuscitation, assessment for associated injuries, and triage of investigations, as well as multimodality hemorrhage control (external fixation, preperitoneal packing, angioembolization, REBOA [resuscitative endovascular balloon occlusion of the aorta]) by multidisciplinary trauma specialists (general surgeons, orthopedic surgeons, endovascular surgeons/interventional radiologists). This article explores this complex clinical problem and provides a practical approach to its management. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Impaired joint motion and contractures in callus distraction and segment transport: a retrospective data analysis.

    PubMed

    Zak, Lukas; Wozasek, Gerald E

    2013-11-01

    The temporary loss of motion of adjacent joints is a common complication after distraction osteogenesis of the lower limb. The aim of this study was to investigate the incidence of tendon contracture and impaired joint motion of the knee and/or ankle joint during and after callus distraction with a ring fixator. Twenty patients (2 female, 18 male, average age: 36 years) were surgically treated for callus distraction and segment transport with an external ring fixator after traumatic bone loss in 21 lower limbs. The impaired joint motion of the adjacent joints during and after treatment was evaluated. During treatment, we observed the free range of motion (ROM) of the ankle joint in 4 cases (19 %), restricted motion in 11 cases (52 %), and complete loss of motion in 6 cases (33 %). After treatment,free ROM was observed in 12 cases (57 %), impaired motion in 3 cases (14 %), and fixed joint position in 6 cases (29 %, 2 arthrodesis). This represents an improvement of motion in eight cases (38 %) and an impairment in two cases (10 %). In 11 cases, the ROM remained unchanged. During treatment, six restrictions in extension (24 %) and five (33 %) restrictions in flexion occurred in the knee joint, ultimately resulting in one loss of extension and three losses of flexion after frame removal. The impairment of joint motion during bone lengthening with an external ring fixator in the lower extremity occurs in most cases at the ankle joint. Various treatment options are available to address tendon shortening, but accompanying physiotherapy may prevent or moderate its onset.

  5. Treatment of segmental tibial fractures with supercutaneous plating.

    PubMed

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-08-01

    Segmental tibial fractures usually follow a high-energy trauma and are often associated with many complications. The purpose of this report is to describe the authors' results in the treatment of segmental tibial fractures with supercutaneous locking plates used as external fixators. Between January 2009 and March 2012, a total of 20 patients underwent external plating (supercutaneous plating) of the segmental tibial fractures using a less-invasive stabilization system locking plate (Synthes, Paoli, Pennsylvania). Six fractures were closed and 14 were open (6 grade IIIa, 2 grade IIIb, 4 grade II, and 2 grade I, according to the Gustilo classification). When imaging studies confirmed bone union, the plates and screws were removed in the outpatient clinic. Average time of follow-up was 23 months (range, 12-47 months). All fractures achieved union. Median time to union was 19 weeks (range, 12-40 weeks) for the proximal fractures and 22 weeks (range, 12-42 weeks) for the distal fractures. Functional results were excellent in 17 patients and good in 3. Delayed union of the fracture occurred in 2 patients. All patients' radiographs showed normal alignment. No rotational deformities and leg shortening were seen. No incidences of deep infection or implant failures occurred. Minor screw tract infection occurred in 2 patients. A new 1-stage protocol using supercutaneous plating as a definitive fixator for segmental tibial fractures is less invasive, has a lower cost, and has a shorter hospitalization time. Surgeons can achieve good reduction, soft tissue reconstruction, stable fixation, and high union rates using supercutaneous plating. The current patients obtained excellent knee and ankle joint motion and good functional outcomes and had a comfortable clinical course. Copyright 2014, SLACK Incorporated.

  6. Fracture following lower limb lengthening in children: a series of 58 patients.

    PubMed

    Launay, F; Younsi, R; Pithioux, M; Chabrand, P; Bollini, G; Jouve, J-L

    2013-02-01

    Fracture is one of the main complications following external fixator removal used in cases of progressive lower limb lengthening; rates as high as 50% are found in the literature. The aim of this study was to determine the factors influencing this complication. One hundred and eleven cases of lower limb lengthening were performed in 58 patients (40 femurs and 71 tibias). The mean age at surgery was 10.1years old. Lengthening was performed in all cases with an external fixator alone, associated in 39.6% of cases with intramedullary nailing. The patients were divided into three groups according to disease etiology (congenital, achondroplasia and other). The fractures were classified according to the Simpson classification. Twenty fractures were recorded (18%). Sixteen fractures were found in patients with congenital disease, four with achondroplasia and none in the group of other etiologies. The fracture was more often in the femur (27.5%) than in the tibia (12.7%). The rate of fracture is influenced by different factors depending on the etiology of disease. In congenital diseases, the fracture rate is higher when there is lengthening of more than 15% of the initial length and a delay between surgery and the beginning of lengthening of less than 7days. In patients with achondroplasia, the influence of a relative percentage of lengthening is less important than in those with congenital disease. However, to avoid fractures, lengthening should not be started in children under the age of nine. Moreover, lengthening should begin at least 7days after the fixator has been placed. Retrospective. Level IV. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  7. Source of the slippage in the universal joints of the Hoffmann external fixator.

    PubMed

    Drijber, F L; Finlay, J B; Moroz, T K; Rorabeck, C H

    1990-01-01

    An investigation was conducted to determine what improvements in the resistance to slippage could be obtained in selected interfaces (rod/clip torsional, cheek/bowl and cheek/clip) of the Hoffmann external fixator. The modification involved changing the standard wing-nut clamp for a bolt with a thread of 7 mm and a 1 mm pitch and placing an FAG 28-303 thrust-bearing (needle roller and cage assembly) between the bolt and the cheek. The results showed a significant improvement in the slippage values of all interfaces; increases of approximately six times were obtained at all torque values of the wing-nut clamp or fastener tested. Such improvements would markedly increase the reliability of external fixation systems and thus reduce the incidence of loss-of-reduction of fracture due to slippage of the universal joint.

  8. Advantages and disadvantages of pinless external fixation.

    PubMed

    Thomas, S R; Giele, H; Simpson, A H

    2000-12-01

    The AO pinless external fixator (PEF) uses trocar tipped clamps to grip the outer tibial cortex rather than pins to transfix it. Its main advantage is to avoid further contamination of the medullary canal in open tibial fractures where a nail may subsequently be used. We tested the anatomical safety of this device and its effect on plastic surgical procedures compared with a standard unilateral external fixator (UEF).The PEF and UEF were placed on two amputated limbs which were then dissected. Structures at risk were traced on ten cadaver limbs. We found that important anatomical structures were endangered by the PEF and that safe zones could not always be defined. The UEF avoided these structures. Plastic surgical approaches were made more difficult by the PEF which imposed limitations on local flap design and endangered the arterial perforators which supply them. We conclude that safety is compromised by the PEF because margins for error are small. It poses additional problems in soft tissue reconstruction and highlights the need for co-operation between plastic surgical and orthopaedic teams in choice of fixation device.

  9. Vacuum sealing drainage therapy in the presence of an external fixation device

    PubMed Central

    Sun, Dahui; Ju, Weina; Wang, Tiejun; Yu, Tiecheng; Qi, Baochang

    2016-01-01

    Abstract Rationale: Vacuum sealing drainage (VSD) is widely utilized for treating traumatic wounds. Patient concerns: It is particularly difficult and time consuming to use in combination with an external fixator. Diagnoses: This is because the hardware or pins used for fixation interfere with maintaining a seal, resulting in poor adhesion and subsequent air leakage. Interventions: To resolve this problem, we have devised a new method for sealing the wound dressing, while maintaining the required vacuum.When using this technique, a rubber strip is wrapped around each pin in 3 circles outside the plastic drape, and then tightly tied. Outcomes: After completing this procedure, a vacuum is obtained, and any air leakage stops. We employed this technique to treat a cohort of patients in our department over a period of two years, and obtained good healing of soft tissue without air leakage, as well as good clinical outcomes. Lessons: We have observed that patients treated with this method experienced good clinical outcomes without air leakage, and we recommend its use in treating cases where an external fixation device is present. PMID:27861393

  10. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome.

    PubMed

    Pan, M; Chai, L; Xue, F; Ding, L; Tang, G; Lv, B

    2017-07-01

    The aim of this study was to compare the biomechanical stability and clinical outcome of external fixator combined with limited internal fixation (EFLIF) and open reduction and internal fixation (ORIF) in treating Sanders type 2 calcaneal fractures. Two types of fixation systems were selected for finite element analysis and a dual cohort study. Two fixation systems were simulated to fix the fracture in a finite element model. The relative displacement and stress distribution were analysed and compared. A total of 71 consecutive patients with closed Sanders type 2 calcaneal fractures were enrolled and divided into two groups according to the treatment to which they chose: the EFLIF group and the ORIF group. The radiological and clinical outcomes were evaluated and compared. The relative displacement of the EFLIF was less than that of the plate (0.1363 mm to 0.1808 mm). The highest von Mises stress value on the plate was 33% higher than that on the EFLIF. A normal restoration of the Böhler angle was achieved in both groups. No significant difference was found in the clinical outcome on the American Orthopedic Foot and Ankle Society Ankle Hindfoot Scale, or on the Visual Analogue Scale between the two groups (p > 0.05). Wound complications were more common in those who were treated with ORIF (p = 0.028). Both EFLIF and ORIF systems were tested to 160 N without failure, showing the new construct to be mechanically safe to use. Both EFLIF and ORIF could be effective in treating Sanders type 2 calcaneal fractures. The EFLIF may be superior to ORIF in achieving biomechanical stability and less blood loss, shorter surgical time and hospital stay, and fewer wound complications. Cite this article : M. Pan, L. Chai, F. Xue, L. Ding, G. Tang, B. Lv. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome. Bone Joint Res 2017;6:433-438. DOI: 10.1302/2046-3758.67.2000640. © 2017 Xue et al.

  11. Fracture healing in mice under controlled rigid and flexible conditions using an adjustable external fixator.

    PubMed

    Röntgen, Viktoria; Blakytny, Robert; Matthys, Romano; Landauer, Mario; Wehner, Tim; Göckelmann, Melanie; Jermendy, Philipp; Amling, Michael; Schinke, Thorsten; Claes, Lutz; Ignatius, Anita

    2010-11-01

    Mice are increasingly used to investigate mechanobiology in fracture healing. The need exists for standardized models allowing for adjustment of the mechanical conditions in the fracture gap. We introduced such a model using rigid and flexible external fixators with considerably different stiffness (axial stiffnesses of 18.1 and 0.82 N/mm, respectively). Both fixators were used to stabilize a 0.5 mm osteotomy gap in the femur of C57BL/6 mice (each n = 8). Three-point bending tests, µCT, and histomorphometry demonstrated a different healing pattern after 21 days. Both fixations induced callus formation with a mixture of intramembranous and enchondral ossification. Under flexible conditions, the bending stiffness of the callus was significantly reduced, and a larger but qualitatively inferior callus with a significantly lower fraction of bone but a higher fraction of cartilage and soft tissue was formed. Monitoring of the animal movement and the ground reaction forces demonstrated physiological loading with no significant differences between the groups, suggesting that the differences in healing were not based on a different loading behavior. In summary, flexible external fracture fixation of the mouse femur led to delayed fracture healing in comparison to a more rigid situation. © 2010 Orthopaedic Research Society.

  12. [Safety evaluation of secondary conversion from external fixation to internal fixation for open tibia fractures].

    PubMed

    Liu, Xi; Cen, Shiqiang; Xiang, Zhou; Zhong, Gang; Yi, Min; Fang, Yue; Liu, Lei; Huang, Fuguo

    2017-06-01

    To evaluate the safety of conversion from external fixation to internal fixation for open tibia fractures. Between January 2010 and December 2014, 94 patients (98 limbs) with open tibia fractures were initially treated with external fixators at the first stage, and the clinical data were retrospectively analyzed. In 29 cases (31 limbs), the external fixators were changed to internal fixation for discomfort, pin tract response, Schantz pin loosening, delayed union or non-union after complete wound healing and normal or close to normal levels of erythrocyte sedimentation rate (ESR), C reactive protein (CRP), and the leucocyte count as well as the neutrophil ratio (trial group); in 65 cases (67 limbs), the external fixators were used as the ultimate treatment in the control group. There was no significant difference in gender, age, side of the limbs, interval from injury to the first debridement, initial pathogenic bacteria, the limbs that skin grafting or flap transferring for skin and soft tissue defect between the two groups ( P >0.05). The incidence of Gustilo type III fractures in the control group was significantly higher than that in the trial group ( P =0.000). The overall incidence of infection was calculated respectively in the two groups. The incidence of infection according to different fracture types and whether skin grafting or flap transferring was compared between the two groups. The information of the pathogenic bacteria was recorded in the infected patients, and it was compared with the results of the initial culture. The incidence of infection in the patients of the trial group using different internal fixation instruments was recorded. The overall incidences of infection for the trial and control groups were 9.7% (3/31) and 9.0% (6/67) respectively, showing no significant difference ( χ 2 =0.013, P =0.909). No infection occurred in Gustilo type I and type II patients. The incidence of infection for Gustilo type IIIA patients in the trial group and the control group were 14.3% (1/7) and 6.3% (2/32) respectively, showing no significant difference ( χ 2 =0.509, P =0.476); the incidence of infection for type IIIB patients in the two groups were 50.0% (2/4) and 14.3% (2/14) respectively, showing no significant difference ( χ 2 =2.168, P =0.141); and the incidence of infection for type IIIC patients in the two groups were 0 and 16.7% (2/12) respectively, showing no significant difference ( χ 2 =0.361, P =0.548). Of all the infected limbs, only 1 limb in the trial group had the same Staphylococcus Aureus as the result of the initial culture. In the patients who underwent skin grafting or flap transferring, the incidence of infection in the trial and control groups were 33.3% (2/6) and 13.3% (2/15) respectively, showing no significant difference ( χ 2 =1.059, P =0.303). After conversion to internal fixation, no infection occurred in the cases that fixed with nails (11 limbs), and infection occurred in 4 of 20 limbs that fixed with plates, with an incidence of infection of 20%. Conversion from external fixation to internal fixation for open tibia fractures is safe in most cases. However, for open tibia fractures with extensive and severe soft tissue injury, especially Gustilo type III patients who achieved wound heal after flap transfer or skin grafting, the choice of secondary conversion to internal fixation should carried out cautiously. Careful pre-operative evaluation of soft tissue status, cautious choice of fixation instrument and meticulous intra-operative soft tissue protection are essential for its safety.

  13. Implant Removal After Internal Fixation of a Femoral Neck Fracture: Effects on Physical Functioning.

    PubMed

    Zielinski, Stephanie M; Heetveld, Martin J; Bhandari, Mohit; Patka, Peter; Van Lieshout, Esther M M

    2015-09-01

    The effect of implant removal after internal fixation of a femoral neck fracture on physical functioning was analyzed. Characteristics of patients who had their implant removed were studied, as it is currently unknown from which type of patients implants are removed and what effect removal has on function. Secondary cohort study alongside a randomized controlled trial. Multicenter study in 14 hospitals. Patients who had their implant removed after internal fixation of a femoral neck fracture are compared with patients who did not. Patient characteristics and quality of life (Short Form 12, Western Ontario McMaster Osteoarthritis Index) were compared. Matched pairs were selected based on patient/fracture characteristics and prefracture physical functioning. Of 162 patients, 37 (23%) had their implant removed. These patients were younger (median age: 67 vs. 72 years, P = 0.024) and more often independently ambulatory prefracture (100% vs. 84%, P = 0.008) than patients who did not. They more often had evident implant back-out on x-rays (54% vs. 34%, P = 0.035), possibly related to a higher rate of Pauwels 3 fractures (41% vs. 22%, P = 0.032). In time, quality of life improved more in implant removal patients [+2 vs. -4 points, Short Form 12 (physical component), P = 0.024; +9 vs. 0 points, Western Ontario McMaster Osteoarthritis Index, P = 0.019]. Implant removal after internal fixation of a femoral neck fracture positively influenced quality of life. Implant removal patients were younger and more often independently ambulatory prefracture, more often had a Pauwels 3 fracture, and an evident implant back-out. Implant removal should be considered liberally for these patients if pain persists or functional recovery is unsatisfactory. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  14. Foot and ankle function after tibial overlengthening.

    PubMed

    Emara, Khaled M; Diab, Ramy Ahmed; El Ghazali, Sherif; Farouk, Amr; El Kersh, Mohamed Ahmed

    2014-01-01

    Lengthening the tibia more than 25% of its original length can be indicated for proximal femoral deficiency, poliomyelitis, or femoral infected nonunion. Such lengthening of the tibia can adversely affect the ankle or foot shape and function. The present study aimed to assess the effect of tibial lengthening of more than 25% of its original length on the foot and ankle shape and function compared with the preoperative condition. This was a retrospective study of 13 children with severe proximal focal femoral deficiency, Aitken classification type D, who had undergone limb lengthening from June 2000 to June 2008 using Ilizarov external fixators. The techniques used in tibial lengthening included lengthening without intramedullary rodding and lengthening over a nail. The foot assessment was done preoperatively, at fixator removal, and then annually for 3 years, documenting the range of motion and deformity of the ankle and subtalar joints and big toe and the navicular height, calcaneal pitch angle, and talo-first metatarsal angle. At fixator removal, all cases showed equinocavovarus deformity, with decreased ankle, subtalar, and big toe motion. The mean American Orthopedic Foot and Ankle Society score was significantly reduced. During follow-up, the range of motion, foot deformity, and American Orthopedic Foot and Ankle Society score improved, reaching nearly to the preoperative condition by 2 years of follow-up. The results of our study have shown that tibial overlengthening has an adverse effect on foot and ankle function. This effect was reversible in the patients included in the present study. Lengthening of more than 25% can be safely done after careful discussion with the patients and their families about the probable effects of lengthening on foot and ankle function. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Accuracy of a hexapod parallel robot kinematics based external fixator.

    PubMed

    Faschingbauer, Maximilian; Heuer, Hinrich J D; Seide, Klaus; Wendlandt, Robert; Münch, Matthias; Jürgens, Christian; Kirchner, Rainer

    2015-12-01

    Different hexapod-based external fixators are increasingly used to treat bone deformities and fractures. Accuracy has not been measured sufficiently for all models. An infrared tracking system was applied to measure positioning maneuvers with a motorized Precision Hexapod® fixator, detecting three-dimensional positions of reflective balls mounted in an L-arrangement on the fixator, simulating bone directions. By omitting one dimension of the coordinates, projections were simulated as if measured on standard radiographs. Accuracy was calculated as the absolute difference between targeted and measured positioning values. In 149 positioning maneuvers, the median values for positioning accuracy of translations and rotations (torsions/angulations) were below 0.3 mm and 0.2° with quartiles ranging from -0.5 mm to 0.5 mm and -1.0° to 0.9°, respectively. The experimental setup was found to be precise and reliable. It can be applied to compare different hexapod-based fixators. Accuracy of the investigated hexapod system was high. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Mechanical rigidity of the Ortho-SUV frame compared to the Ilizarov frame in the correction of femoral deformity.

    PubMed

    Skomoroshko, Petr V; Vilensky, Victor A; Hammouda, Ahmed I; Fletcher, Matt D A; Solomin, Leonid N

    2015-04-01

    The Ortho-SUV frame (OSF) is a novel hexapod circular external fixator which draws upon the innovation of the Ilizarov method and the advantages of hexapod construction in the three-dimensional control of bone segments. Stability of fixation is critical to the success or failure of an external circular fixator for fracture or osteotomy healing. In vitro biomechanical modelling study was performed comparing the stability of the OSF under load in both original form and after dynamisation to the Ilizarov fixator in all zones of the femur utilising optimal frame configuration. A superior performance of the OSF in terms of resistance to deforming forces in both original and dynamised forms over that of the original Ilizarov fixator was found. The OSF shows higher rigidity than the Ilizarov in the control of forces acting upon the femur. This suggests better stabilisation of femoral fractures and osteotomies and thus improved healing with a reduced incidence of instability-related bone segment deformity, non-union and delayed union.

  17. Posterior cervical fixation for fracture and degenerative disc disease.

    PubMed

    An, H S; Coppes, M A

    1997-02-01

    There are numerous newer techniques that have been developed for the internal fixation of the cervical spine in recent years. Wiring techniques are still appropriate for posterior stabilization of the cervical spine. The halo vest is still widely used for the conservative management of cervical fractures and for postoperative external immobilization. The authors stress that the surgical indications for more modern rigid implants should be adhered to strictly. These implants also should be selected by weighing their advantages versus potential risks. In the upper cervical spine, the surgeon may choose traditional wiring methods and newer C1-C2 screw fixation, occipitocervical plate fixation. For the lower cervical spine, triple wiring technique or lateral mass plating may be used. The surgeon must choose an appropriate device based on the mechanism of injury, pathoanatomy of the lesion, and familiarity with the device, keeping in mind that the goals of internal fixation are stabilization, reduction and maintenance of alignment, early rehabilitation and perhaps enhancement of fusion rates, and avoidance of use of an external halo vest.

  18. Successful correction of tibial bone deformity through multiple surgical procedures, liquid nitrogen-pretreated bone tumor autograft, three-dimensional external fixation, and internal fixation in a patient with primary osteosarcoma: a case report.

    PubMed

    Takeuchi, Akihiko; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Watanabe, Koji; Miwa, Shinji; Tsuchiya, Hiroyuki

    2015-12-07

    In a previous report, we described a method of reconstruction using tumor-bearing autograft treated by liquid nitrogen for malignant bone tumor. Here we present the first case of bone deformity correction following a tumor-bearing frozen autograft via three-dimensional computerized reconstruction after multiple surgeries. A 16-year-old female student presented with pain in the left lower leg and was diagnosed with a low-grade central tibial osteosarcoma. Surgical bone reconstruction was performed using a tumor-bearing frozen autograft. Bone union was achieved at 7 months after the first surgical procedure. However, local tumor recurrence and lung metastases occurred 2 years later, at which time a second surgical procedure was performed. Five years later, the patient developed a 19° varus deformity and underwent a third surgical procedure, during which an osteotomy was performed using the Taylor Spatial Frame three-dimensional external fixation technique. A fourth corrective surgical procedure was performed in which internal fixation was achieved with a locking plate. Two years later, and 10 years after the initial diagnosis of tibial osteosarcoma, the bone deformity was completely corrected, and the patient's limb function was good. We present the first report in which a bone deformity due to a primary osteosarcoma was corrected using a tumor-bearing frozen autograft, followed by multiple corrective surgical procedures that included osteotomy, three-dimensional external fixation, and internal fixation.

  19. Treatment of unstable distal radius fractures with Ilizarov circular, nonbridging external fixator.

    PubMed

    Tyllianakis, Minos; Mylonas, Spyros; Saridis, Alkis; Kallivokas, Alkiviadis; Kouzelis, Antonis; Megas, Panagiotis

    2010-03-01

    Unstable distal radius fractures remain a challenge for the treating orthopaedic surgeon. We present a retrospective follow-up study (mean follow-up 12.5 months) of 20 patients with 21 unstable distal radius fractures that were reduced in a closed manner and stabilized with a nonbridging Ilizarov external fixator. Subsequent insertion of olive wires for interfragmentary compression was performed in cases with intra-articular fractures. According to the overall evaluation proposed by Gartland and Werley scoring system 12 wrists were classified as excellent, 6 as good, 2 as fair and 1 as poor. Grade II pin-tract infection in distal fracture fragment was detected in 3 wires from a total of 78 (3.8%) and in 4 half pins out of a total of 9 (44.4%). Pronation was the most frequently impaired movement. This was restricted in 4 patients (19%) in whom a radioulnar transfixing wire was applied. Symptoms of irritation of superficial sensory branch of the radial nerve occurred in 3 patients with an olive wire applied in a closed manner in the distal fragment. Ilizarov method yields functional results comparable to that of other methods whilst it avoids wrist immobilization, open reduction and reoperation for implant removal. The method is associated with a low rate of major complication and satisfactory functional outcome. Copyright 2009 Elsevier Ltd. All rights reserved.

  20. [Arthrodesis of the infected ankle joint: results with the Ilizarov external fixator].

    PubMed

    Gessmann, J; Ozokyay, L; Fehmer, T; Muhr, G; Seybold, D

    2011-04-01

    The treatment of severe bacterial infections of the ankle joint is difficult and complex. In the case of a chronic infection with destruction of the ankle joint, a tibiotalar arthrodesis with external fixation is the treatment of choice. In this study the results of ankle arthrodesis due to bacterial infection using the Ilizarov external fixator are presented. Between 2001 and 2004 37 patients (10 female, 27 male, mean age 58 years) were treated with a tibiotalar arthrodesis using the Ilizarov fixator. All patients had a confirmed infection in the course of their disease. Active infection was present in 20 patients at the time of the operation. Most secondary ankle arthritides (81 %) were caused post-traumatically after various internal fixation procedures. Previous ankle arthrodeses were tried in 14 cases (12 cases with internal fixation, two cases with external monolateral fixation). Patients were treated with a four-ring Ilizarov frame (in two cases with a five-ring frame) and stainless steel wires. All patients could be included at a mean follow-up of 46 (12-49) months. A modified AOFAS score was used for the functional outcome. The operation took 141 minutes at an average ranging from 90 to 252 minutes. The inpatient treatment lasted between 10 and 63 days (mean 26 days). The time spent in the fixator was 116.7 (69-245) days. All patients were mobilised under full weight bearing with the external fixator. Surgical revision was necessary in 13 patients: four patients needed wound revisions due to ongoing infection, six patients needed wire exchange due to deep infection in three cases and wire breakage in three cases, one patient needed additional wires because of an initially instable frame configuration and two patients needed secondary skin grafting. Bony consolidation was achieved in 32 patients (86.5 %). With a re-arthrodesis performed in four patients using the Ilizarov fixator, the overall fusion rate was 94.6 %. Infection was persistent in two cases with one solid ankle fusion and one ankle pseudarthrosis. At the time of follow-up 35 patients were able to walk under full weight loading with orthopaedic shoe modifications, four patients needed support of a cane and three patients wore an ankle-foot orthesis. The two patients with persistent pseudarthrosis were mobilised in a lower-leg orthesis after declining another surgical revision. The positioning of the hindfoot showed in seven cases an equinus of 10°, in one case a varus of 10° and in two cases a valgus positioning of 10°. A plantigrade foot positioning or with minimal degrees of deviation could be achieved in all other cases. The modified AOFAS score at the time of the follow-up examination ranged from 19 to 86 with an average score of 67.9 points. All patients except three were satisfied or rather satisfied with the treatment procedure and its results. The Ilizarov external fixator is a safe method for ankle fusion in cases of infection. The advances are a possible application at acute infection and immediate mobilisation at full weight bearing. However, it remains a time-consuming and stressful procedure for the patient. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Use of an elastic transarticular external fixator construct for immobilization of the elbow joint.

    PubMed

    Vedrine, Bertrand

    2017-04-01

    Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation.

  2. Use of an elastic transarticular external fixator construct for immobilization of the elbow joint

    PubMed Central

    Vedrine, Bertrand

    2017-01-01

    Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation. PMID:28373726

  3. Operative stabilization of open long bone fractures: A tropical tertiary hospital experience

    PubMed Central

    Ifesanya, Adeleke O.; Alonge, Temitope O.

    2012-01-01

    Background: Operative treatment of open fractures in our environment is fraught with problems of availability of theater space, appropriate hardware, and instrumentation such that high complication rates may be expected. Materials and Methods: We evaluated all open long bone fractures operatively stabilized at our center to determine the outcome of the various treatment modalities as well as the determinant factors. Result: A total of 160 patients with 171 fractures treated between December 1995 and December 2008 were studied. There were twice as many males; mean age was 35.0 years. About half were open tibia fractures. Gustilo IIIa and IIIb fractures each accounted for 56 cases (45.2%). Fifty-three percent were stabilized within the first week of injury. Interval between injury and operative fixation averaged 11.1 days. Anderson-Hutchin's technique was employed in 27 cases (21.8%), external fixation in 21 (16.9%), plate osteosynthesis in 50 (40.3%), and intramedullary nail 15 cases (12.1%). Mean time to union was 24.7 weeks. Fifty-two complications occurred in 50 fractures (40.3%) with joint stiffness and chronic osteomyelitis each accounting for a quarter of the complications. Union was delayed in grade IIIb open fractures and those fractures treated with external fixation. Conclusion: A significant proportion of open long bone fractures we operatively treated were severe. Severe open fractures (type IIIb) with concomitant stabilization using external fixation delayed fracture union. While we recommend intramedullary devices for open fractures, in our setting where locking nails are not readily available, external fixation remains the safest choice of skeletal stabilization particularly when contamination is high. PMID:23271839

  4. Analysis of strategies to increase external fixator stiffness: is double stacking worth the cost?

    PubMed

    Strebe, Sara; Kim, Hyunchul; Russell, Joseph P; Hsieh, Adam H; Nascone, Jason; O'Toole, Robert V

    2014-07-01

    We compared the mechanical benefits and costs of 3 strategies that are commonly used to increase knee-spanning external fixator stiffness (resistance to deformation): double stacking, cross-linking, and use of an oblique pin. At our academic trauma centre and biomechanical testing laboratory, we used ultra-high-molecular-weight polyethylene bone models and commercially available external fixator components to simulate knee-spanning external fixation. The models were tested in anterior-posterior bending, medial-lateral bending, axial compression, and torsion. We recorded the construct stiffness for each strategy in all loading modes and assessed a secondary outcome of cost per 10% increase in stiffness. Double stacking significantly increased construct stiffness under anterior-posterior bending (109%), medial-lateral bending (22%), axial compression (150%), and torsion (41%) (p<0.05). Use of an oblique pin significantly increased stiffness under torsion (25%) (p<0.006). Cross-linking significantly increased stiffness only under torsion (29%) (p<0.002). Double stacking increased costs by 84%, cross-linking by 28%, and use of an oblique pin by 15% relative to a standard fixator. All 3 strategies increased stiffness under torsion to varying degrees, but only double stacking increased stiffness in all 4 testing modalities (p<0.05). Double stacking is most effective in increasing resistance to bending, particularly under anterior-posterior bending and axial compression, but requires a relatively high cost increase. Clinicians can use these data to help guide the most cost-effective strategy to increase construct stiffness based on the plane in which stiffness is needed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Comparing Different Surgical Techniques for Addressing the Posterior Malleolus in Supination External Rotation Ankle Fractures and the Need for Syndesmotic Screw Fixation.

    PubMed

    Li, Mengnai; Collier, Rachel C; Hill, Brian W; Slinkard, Nathaniel; Ly, Thuan V

    Trimalleolar ankle fractures are unstable injuries with possible syndesmotic disruption. Recent data have described inherent morbidity associated with screw fixation of the syndesmosis, including the potential for malreduction, hardware irritation, and post-traumatic arthritis. The posterior malleolus is an important soft tissue attachment for the posterior inferior syndesmosis ligament. We hypothesized that fixation of a sizable posterior malleolar (PM) fracture in supination external rotation type IV (SER IV) ankle fractures would act to stabilize the syndesmosis and minimize or eliminate the need for trans-syndesmotic fixation. A retrospective review of trimalleolar ankle fractures surgically treated from October 2006 to April of 2011 was performed. A total of 143 trimalleolar ankle fractures were identified, and 97 were classified as SER IV. Of the 97 patients, 74 (76.3%) had a sizable PM fragment. Syndesmotic fixation was required in 7 of 34 (20%) and 27 of 40 (68%), respectively, when the PM was fixed versus not fixed (p = .0002). When the PM was indirectly reduced using an anterior to posterior screw, 7 of 15 patients (46.7%) required syndesmotic fixation compared with none of 19 patients when the PM fragment was fixated with direct posterior lateral plate fixation (p = .0012). Fixation of the PM fracture in SER IV ankle fractures can restore syndesmotic stability and, thus, lower the rate of syndesmotic fixation. We found that fixation of a sizable PM fragment in SER IV or equivalent injuries through posterolateral plating can eliminate the need for syndesmotic screw fixation. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. The management of tibial pilon fractures with the Ilizarov fixator: The role of ankle arthroscopy.

    PubMed

    El-Mowafi, Hani; El-Hawary, Ahmed; Kandil, Yasser

    2015-12-01

    Pilon fractures usually result from high energy trauma, and are commonly associated with extensive soft tissue damage which prevents the use of open reduction and internal fixation. This study was designed to evaluate the use of the Ilizarov external fixator in the treatment of pilon fractures of the ankle, and to determine whether arthroscopy of the ankle could improve the outcome. From February 2011 to May 2013 a total of 23 patients with unilateral closed pilon fractures were divided into two groups treated with and without arthroscopy during fixation with the Ilizarov external fixator. The fractures were classified according to the AO Rüdi and Allgőwer classification. Follow up ranged from 10 to 37 months with a mean of 18 months. All cases were evaluated at follow up by the AOFAS and the Bone et al. grading system. According to Bone et al. there were 3 cases excellent, 4 cases good, 2 cases fair, and 2 cases poor in Group A (without arthroscopy), whereas there were 4 cases excellent, 6 cases good, 2 cases fair in Group B (with arthroscopy). The AOFAS score for Group A was 77.8±5.8, and for Group B was 78.4±6.9. We concluded that the Ilizarov external fixator is an excellent method in treating pilon fractures as it minimizes the need for extensive surgery. We also conclude that the use of arthroscopy during pilon fracture fixation did not add statistically significant improvement to our results and it needs longer term investigation to assess its advantage - if any - to the final outcome. level 2. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Treatment Approach for Infection of Healed Fractures After Internal Fixation.

    PubMed

    Lawrenz, Joshua M; Frangiamore, Salvatore J; Rane, Ajinkya A; Cantrell, William Alex; Vallier, Heather A

    2017-11-01

    To review the efficacy of a treatment approach for patients with infection and colonized implants after open reduction and internal fixation of fractures. Retrospective case series. Level one trauma center. Twenty patients were treated for wound infection with colonized implants after open reduction and internal fixation. Surgical debridement, removal of implants, and a short postoperative oral antibiotic course. The course of patients after surgical debridement and removal of implants, including culture results, antibiotic administration, and presence of recurrent clinical infection and radiographic union. Twenty patients had clinical presentations, including skin breakdown, serous drainage, purulent drainage and/or exposed implants, most commonly of the tibia (15 of 20). Mean time from index procedure to debridement with implant removal was 19.7 months. At the time of debridement and implant removal, 18 of 20 (90%) patients had a positive intraoperative culture (16 routine cultures and 2 broth cultures). The most common bacteria were Enterobacter cloacae (5/17) and methicillin-sensitive Staphylococcus aureus (4/17). All patients had soft tissue healing without signs of recurrent infection after mean follow up of 40 months after implant removal. Surgical debridement with implant removal plus a short oral antibiotic course is effective to resolve wound infection with a colonized implant in the setting of healed fracture after internal fixation. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  8. Plate fixation or intramedullary fixation for midshaft clavicle fractures: a systematic review and meta-analysis of randomized controlled trials and observational studies.

    PubMed

    Houwert, Roderick M; Smeeing, Diederik P J; Ahmed Ali, Usama; Hietbrink, Falco; Kruyt, Moyo C; van der Meijden, Olivier A

    2016-07-01

    The last decade has shown a shift toward operative treatment of a subset of midshaft clavicle fractures. However, it is unclear whether there are differences between plate fixation and intramedullary fixation regarding complications and functional outcome. The aim of this systematic review and meta-analysis was to compare plate fixation and intramedullary fixation for midshaft clavicle fractures. The Medline, Embase, and Cochrane databases were searched for both randomized controlled trials and observational studies. The methodologic quality of all included studies was assessed using the Methodological Index for Non-Randomized Studies. Twenty studies were included. Ten of the 20 included studies used a fracture classification. Seven of these studies reported exclusion of patients with comminuted fractures. No difference in the total re-intervention rate was found (odds ratio [OR], 1.21; 95% confidence interval [CI], 0.71 to 2.04). Major re-interventions occurred more often after plate fixation (OR, 1.88; 95% CI, 1.02 to 3.46). The mean implant removal rates were 38% after plate fixation and 73% after intramedullary fixation. Re-fracture after implant removal occurred more often after plate fixation (OR, 3.42; 95% CI, 1.12 to 10.42). The Constant-Murley scores showed no differences at both short term (mean difference, -1.18; 95% CI, -13.41 to 11.05) and long term (mean difference, 0.15; 95% CI, -1.57 to 1.87). No differences were observed regarding nonunion (OR, 1.50; 95% CI, 0.82 to 2.75). The rate of infections showed no differences when outlier studies were excluded (OR, 1.54; 95% CI, 0.88 to 2.69). Major re-intervention and re-fracture after implant removal occurred more frequently after plate fixation of non-comminuted, displaced midshaft clavicle fractures. No differences in terms of function and nonunion between plate fixation and intramedullary fixation were observed. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. Biomechanical comparison of supraacetabular external fixation and anterior pelvic bridge plating.

    PubMed

    Çavuşoğlu, Ali Turgay; Erbay, Fatma Kübra; Özsoy, Mehmet Hakan; Demir, Teyfik

    2017-10-01

    Unstable pelvic ring injuries are complex and risky injuries due to high morbidity and mortality. Although anterior pelvic external fixator is a suitable method for rapid stabilization of an injured pelvic ring, due to some disadvantages such as high complication rate, nerve damage, and difficulties of patient's mobility and comfort, there has recently been increased searching for alternative methods for stabilization of the pelvic ring. Pubic symphysis zone freely moves in pelvic models. This study aims to evaluate the biomechanical stability of anterior pelvic bridge plating and compare it with supraacetabular external fixators in an untreated unstable pelvic fracture model. Samples were loaded statically with 2-mm/min loading rate in single leg standing position. Maximum load was 2.3 kN. When loading the samples, photographs were taken continuously. Stiffness values were calculated from the load displacement curves. Some reference parameters were described and were measured from unloaded and 2.3-kN-loaded photographs of the test. The mean stiffness values were 491.14 ± 52.22, 478.55 ± 41.44, and 470.25 ± 44.51 N/mm for anterior pelvic bridge plating group, supraacetabular external fixator group, and Control group, respectively. According to the measured parameters from photographs, the mean displacement at the pubic symphysis was 4.7 ± 0.32, 15.8 ± 2.01, and 18.2 ± 0.47 mm for anterior pelvic bridge plating, supraacetabular external fixator, and Control group, respectively. The highest displacement in the pubic symphysis was found in Control group, and minimum displacement was observed in anterior pelvic bridge plating group. When the perpendicular distance between the right and left lower end of ischium was examined, it was observed that displacement was minimum in anterior pelvic bridge plating group compared to other two groups, regarding to the high stability of pubic symphysis. In conclusion, this study revealed superiority of anterior subcutaneous plate fixation with biomechanical results.

  10. Complex tibial fractures are associated with lower social classes and predict early exit from employment and worse patient-reported QOL: a prospective observational study of 46 complex tibial fractures treated with a ring fixator.

    PubMed

    Elsoe, Rasmus; Larsen, Peter; Petruskevicius, Juozas; Kold, Søren

    2018-04-01

    The long-term outcomes following complex fractures of the tibia are reported to carry a risk of knee pain, malalignment, articular injury and post-traumatic osteoarthritis. The main objective of this study was to account for the patient-reported quality of life (QOL) 12 months after ring fixator removal in patients with a complex tibial fracture. Secondary objectives included a review of the socio-economic characteristics of the patient group and the rate of return to work in the study period. A prospective follow-up study was conducted of 60 patients with complex fractures of the tibia treated with ring external fixation. Patient-reported outcomes, radiological outcomes and socio-economic status including employment status of the patients were obtained 12 months after frame removal. Forty-six patients completed the assessment 12 months after frame removal (77%). The mean age of the patient at the time of fracture was 54.6 years (range 31-86). There were 19 males and 27 females. At 12 months after frame removal, the mean EQ5D-5L index was 0.66 (CI 0.60-0.72). The mean EQ5D-5L VAS was 69 (CI 61-76). When this was compared to the established reference population from Denmark, the study population showed a significantly worse EQ5D-5L index. The majority of patients (87%) were in the lower social classes suggesting a higher degree of social deprivation in the study population. Twenty-seven per cent of patients who were employed prior to injury had returned to employment at approximately 19 months following fracture. The onset of post-traumatic osteoarthritis was present in the knee joint in 29% of patients following a proximal intra-articular fracture, whereas osteoarthritis was present at the ankle joint in 35% of patients following a distal intra-articular fracture 12 months after frame removal. This study indicates that at 12 months after frame removal there are poorer patient-reported QOL as when compared to reference populations. Furthermore, this study suggests that complex tibial fractures are associated with lower social classes and that only 27% of patients in this sample, who prior to injury were employed, had returned to employment at approximately 19 months after the injury.

  11. Releasing the circumferential fixation of the medial meniscus does not affect its kinematics.

    PubMed

    Vrancken, A C T; van Tienen, T G; Hannink, G; Janssen, D; Verdonschot, N; Buma, P

    2014-12-01

    Meniscal functioning depends on the fixation between the meniscal horns and the surrounding tissues. It is unknown, however, whether the integration between the outer circumference of the medial meniscus and the knee capsule/medial collateral ligament also influences the biomechanical behavior of the meniscus. Therefore, we aimed to determine whether detaching and resuturing the circumferential fixation of the medial meniscus influence its kinematic pattern. Human cadaveric knee joints were flexed (0°-30°-60°-90°) in a knee loading rig, in neutral orientation and under internal and external tibial torques. Roentgen stereophotogrammetric analysis was used to determine the motion of the meniscus in anteroposterior (AP) and mediolateral (ML) directions. Three fixation conditions were evaluated: (I) intact, (II) detached and (III) resutured. Detaching and resuturing the circumferential fixation did not alter the meniscal motion pattern in either the AP or ML direction. Applying an additional internal tibial torque caused the medial meniscus to move slightly anteriorly, and an external torque caused a little posterior translation with respect to the neutral situation. These patterns did not change when the circumferential fixation condition was altered. This study demonstrated that the motion pattern of the medial meniscus is independent of its fixation to the knee capsule and medial collateral ligament. The outcomes of this study can be deployed to design the fixation strategy of a permanent meniscus prosthesis. As peripheral fixation is a complicated step during meniscal replacement, the surgical procedure is considerably simplified when non-resorbable implants do not require circumferential fixation. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Treatment of unstable intraarticular fracture of distal radius: POP casting with external fixation.

    PubMed

    ur Rahman, Obaid; Khan, Mohammad Qadeem; Rasheed, Haroon; Ahmad, Saleem

    2012-04-01

    To compare radiological and functional outcome of external fixation and distraction with conservative Plaster of Paris (POP) cast for unstable intra-articular fractures of the distal radius. The study was conducted on 60 patients with unstable intra-articular fracture of distal radius who reported to emergency or outpatient Orthopaedic Surgery department of Benazir Bhutto Hospital, Rawalpindi, between March and August 2007. They were divided into two equal groups: Group A and Group B, treated by Plaster of Paris cast, and external fixation with distraction respectively. The functional outcome in terms of freedom from pain, range of movement, grip power and deformity, and the radiological outcome of radial length, incongruity and radio-ulnar joint position were analysed at three months follow-up using a 3-point scoring scale. In Group A, 1 (3%) patient showed excellent result, 8 (27%) patients good results, 19 (63%) patients fair results and 2 (7%) patients poor result. In Group B, 14 (47%) patients showed excellent results, 11 (37%) patients good results, 4 (13%) patients fair results and 1 (3%) patient poor result. The outcome score of the Group B patients was significantly better compared to the Group A patients (p value < 0.05). External fixation has definite advantages over conventional Plaster of Paris cast in the treatment of unstable intra-articular fractures of distal radius.

  13. [Manipulative reduction and percutaneous Kirschner wire internal fixation for grade IV supination-external rotation ankle fractures].

    PubMed

    Li, Jia; Sun, Jin-Ke; Wang, Chen-Lin

    2017-06-25

    To investigate surgical skills and clinical effects of manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures. From May 2013 to October 2016, 35 patients with grade IV supination-external rotation ankle fractures were treated with percutaneous Kirschner wire internal fixation, involving 22 males and 13 females with an average age of 38.2 years ranged from 18 to 65 years old. The time from injury to operation ranged from 2 h to 10 d with an average of 5 d. Reduction quality was assessed by Burwell-Charnley radiological criteria. Baird-Jackson ankle scoring system was used to assess clinical effects. Thirty-three patients were followed up from 10 to 28 months with an average of 14 months. Fracture healing time ranged from 10 to 18 weeks with an average of 12 weeks. According to Burwell-Charnley radiological criteria, 30 cases were obtained anatomic reduction, 3 cases moderate. According to Baird-Jackson ankle scoring system, total score was 93.8±5.4, 17 cases got excellent result, 12 good, 2 fair and 2 poor. Manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures has advantages of reliable efficacy, less complications. But higher require techniques were required for closed reduction. It is not suitable for severe crushed fracture and compressive articular surface fracture.

  14. Surgical correction of bilateral metacarpophalangeal valgus with curved osteotomies and type II external skeletal fixation in a seven-month-old alpaca.

    PubMed

    Schoonover, Mike J; Whitfield, Chase T; Rochat, Mark C; Streeter, Robert N; Sippel, Kate

    2016-09-20

    To report the successful surgical correction of severe bilateral metacarpophalangeal valgus angular limb deformities in a seven-month-old intact male alpaca cria using curved osteotomies stabilized with type II external skeletal fixation. Using a 21 mm crescentic shaped oscillating saw blade, bilateral osteotomies were performed in the distal metaphyses of the fused third and fourth metacarpal bones to correct valgus angular limb deformity of the metacarpophalangeal joints. Axial alignment of each limb was achieved by medially rotating the distal metacarpus in the frontal plane along the curved osteotomies. The osteotomies were stabilized using type II external skeletal fixators. The alpaca was immediately weight-bearing following the surgical procedure and no to minimal lameness was observed during healing of the osteotomies. Evaluation at five and 10 months following the surgery demonstrated acceptable axial alignment in the left forelimb while moderate to severe varus deformity (overcorrection) was observed in the right. Curved osteotomy of the distal metacarpus stabilized with type II external skeletal fixation can provide a favourable outcome in older alpaca crias affected with metacarpophalangeal angular limb deformities. Placement of the distal transfixation pins relative to the metacarpal physes should be carefully evaluated as overcorrection is possible, especially if growthpotential remains in only one physis of the fused third and fourth metacarpal bones.

  15. Implant Removal after Percutaneous Short Segment Fixation for Thoracolumbar Burst Fracture : Does It Preserve Motion?

    PubMed Central

    Kim, Hyeun Sung; Ju, Chang Il; Wang, Hui Sun; Lee, Sung Myung; Kim, Dong Min

    2014-01-01

    Objective The purpose of this study was to evaluate the efficacy of implant removal of percutaneous short segment fixation after vertebral fracture consolidation in terms of motion preservation. Methods Between May 2007 and January 2011, 44 patients underwent percutaneous short segment screw fixation due to a thoracolumbar burst fracture. Sixteen of these patients, who underwent implant removal 12 months after screw fixation, were enrolled in this study. Motor power was intact in all patients, despite significant vertebral height loss and canal compromise. The patients were divided into two groups by degree of osteoporosis : Group A (n=8), the non-osteoporotic group, and Group B (n=8), the osteoporotic group. Imaging and clinical findings including vertebral height loss, kyphotic angle, range of motion (ROM), and complications were analyzed. Results Significant pain relief was achieved in both groups at final follow-up versus preoperative values. In terms of vertebral height loss, both groups showed significant improvement at 12 months after screw fixation and restored vertebral height was maintained to final follow-up in spite of some correction loss. ROM (measured using Cobb's method) in flexion and extension in Group A was 10.5° (19.5/9.0°) at last follow-up, and in Group B was 10.2° (18.8/8.6°) at last follow-up. Both groups showed marked improvement in ROM as compared with the screw fixation state, which was considered motionless. Conclusion Removal of percutaneous implants after vertebral fracture consolidation can be an effective treatment to preserve motion regardless of osteoporosis for thoracolumbar burst fractures. PMID:24653799

  16. Nonunion of the humerus following intramedullary nailing treated by Ilizarov hybrid fixation.

    PubMed

    Raschke, M; Khodadadyan, C; Maitino, P D; Hoffmann, R; Südkamp, N P

    1998-02-01

    A case of a posttraumatic humeral shaft nonunion, after intramedullary stabilization with a Seidel nail, is presented. Severe osteoporosis, an oligotrophic nonunion, subclinical infection, and adhesive capsulitis of the glenohumeral joint were present. Due to the subclinical infection and severe osteoporosis, other major invasive therapeutic options such as intramedullary nailing or compression plating and bone grafting were not applicable. Nonoperative treatment was also not indicated secondary to the pain and disability present. External fixation with the Ilizarov hybrid fixator seemed to offer a minimally invasive treatment modality without the need of additional bone grafting. After fourteen weeks of "callus massage," consisting of closed alternating compression and distraction with an Ilizarov hybrid fixator, osseous consolidation was achieved. Eight months after Ilizarov treatment the patient had returned to work as a mechanic. At the one-year follow-up examination, the patient presented pain free and with near normal shoulder and elbow motion, with stable osseous consolidation of the humerus. In some cases of nonunion of the humerus shaft, when standard treatment options are not recommended, external fixation with an Ilizarov hybrid fixator may offer a salvage procedure with a successful clinical outcome.

  17. Two-stage open reduction and internal fixation versus limited internal fixation combined with external fixation: a meta-analysis of postoperative complications in patients with severe Pilon fractures.

    PubMed

    Cui, Xueliang; Chen, Hui; Rui, Yunfeng; Niu, Yang; Li, He

    2018-01-01

    Objectives Two-stage open reduction and internal fixation (ORIF) and limited internal fixation combined with external fixation (LIFEF) are two widely used methods to treat Pilon injury. However, which method is superior to the other remains controversial. This meta-analysis was performed to quantitatively compare two-stage ORIF and LIFEF and clarify which method is better with respect to postoperative complications in the treatment of tibial Pilon fractures. Methods We conducted a meta-analysis to quantitatively compare the postoperative complications between two-stage ORIF and LIFEF. Eight studies involving 360 fractures in 359 patients were included in the meta-analysis. Results The two-stage ORIF group had a significantly lower risk of superficial infection, nonunion, and bone healing problems than the LIFEF group. However, no significant differences in deep infection, delayed union, malunion, arthritis symptoms, or chronic osteomyelitis were found between the two groups. Conclusion Two-stage ORIF was associated with a lower risk of postoperative complications with respect to superficial infection, nonunion, and bone healing problems than LIFEF for tibial Pilon fractures. Level of evidence 2.

  18. Hybrid external fixation in high-energy elbow fractures: a modular system with a promising future.

    PubMed

    Lerner, A; Stahl, S; Stein, H

    2000-12-01

    Severe, high-energy, periarticular elbow injuries producing a "floating joint" are a major surgical challenge. Their reconstruction and rehabilitation are not well documented. Therefore, the following reports our experience with treating such injuries caused by war wounds. Seven adults with compound open peri- and intra-articular elbow fractures were treated in hybrid ring tubular fixation frames. After debridement, bone stabilization, and neurovascular reconstructions, early controlled daily movements were started in the affected joint. These seven patients had together seven humeral, five radial, and six ulnar fractures. All fractures united at a median time of 180 days. No deep infection developed. The functional end results assessed by the Khalfayan functional score were excellent in two, good in one, and fair in four of these severely mangled upper extremities. None was amputated. The Mangled Extremity Severity Score has been shown to be unable to provide a reliable assessment for severe high-energy limb injuries surgically managed with the modular hybrid thin wire tubular external fixation system. This hybrid system is a very useful addition to the surgical armamentarium of orthopedic trauma surgeons. It both allows complex surgical reconstructions and reduces the incidence of deep infections in these heavily contaminated injuries. The hybrid circular (thin wire) external fixation system is very modular and may provide secure skeletal stabilization even in cases of severely comminuted juxta-articular fractures on both sides of the elbow joint (floating elbow) with severe damage to soft tissues. This fixation system allows individual fixation of forearm bone fractures, thus allowing the preservation of pronation-supination movements.

  19. Nature and results of treatment of war wounds caused by cluster bombs.

    PubMed

    Mitković, Milorad; Bumbasirević, Marko; Grubor, Predrag; Milenković, Sasa; Micić, Ivan; Stojiljković, Predrag; Kostić, Igor; Karaleić, Sasa; Stamenić, Sonja; Pavlović, Predrag; Stanojlović, Milos; Jovanović, Vladimir; Radovanović, Zoran; Cirić, Tamara; Kutlesić-Stojanović, Katarina; Mitković, Milan

    2013-01-01

    The aim of this study is to describe the nature of war wounds with fracture caused by cluster bombs and to suggest treatment options for such injuries. The nature of wounds caused by cluster bombs differs from those caused by conventional arms (they are more severe). The sides of the wounds are represented by conquasated soft tissues (such as fat and muscle) with thick dead tissues, ordinarily with a thickness of 0.5-4.5 cm. Another main characteristic of such injuries is the high percentage of amputations needed due to the high rate of neurovascular damage. This paper investigates the cases of 81 patients who sustained a total of 99 war wounds with fractures. The average age of the patients was 32.7 years while the youngest was 20 and the oldest, 77. According to The International Committee of the Red Cross (ICRC) classification of war wounds, 14 patients had grade I injuries, 48 patients grade II, and 29 patients, grade III. Mitkovic external fixation system, known also as the "War Fixator" was used for all fractures fixation. One protocol, which was a modification of the ICRC's protocol adapted to our specific conditions, was used throughout the study. For solving soft tissue defects, a rotator fasciocutan flap was the most frequently used. For solving of bones defect Mitkovic reconstructive external fixation device was used. All fractures we treated healed. We concluded that shortening the procedural time and being a very simple, immediate using of Mitkovic versatile external fixator ("War Fixator") is, leads to desirable results.

  20. Fixation of silicone stents in the subglottic trachea: preventing stent migration using a fixation apparatus.

    PubMed

    Miwa, Keisuke; Takamori, Shinzo; Hayashi, Akihiro; Fukunaga, Mari; Shirouzu, Kazuo

    2004-12-01

    Silicone stents are widely used to treat benign or malignant airway stenosis. However, since straight silicone stents placed into the subglottic trachea to treat stenosis display a high risk of migration, novel approaches are required. The present report outlines our method of external fixation for silicone stents in the subglottic trachea. This technique utilizes a fixation apparatus, is readily performed, and may help to overcome the hesitation seen in placing silicone stents for subglottic tracheal stenosis.

  1. Treatment of high-energy pilon fractures using the ILIZAROV treatment.

    PubMed

    Osman, Walid; Alaya, Zeineb; Kaziz, Hamdi; Hassini, Lassad; Braiki, Meriem; Naouar, Nader; Ben Ayeche, Mohamed Laaziz

    2017-01-01

    The management of high-energy pilon fractures is still controversial. Open reduction and internal fixation are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. The aim of this retrospective study was to analyze the clinical and radiographic outcome of the ILIZAROV technique in patients with high-energy pilon fractures. Thirty cases of distal tibia epiphysis fractures (pilon fractures) were managed from 1999 to 2012. The study group included 5 cases of open fractures. The mean age was 47 years. According to Rüedi and Algower classification; 11 fractures were type II, and 19 type III. All fractures were a consequence of high-energy trauma. Fractures of the lower fibula were present in 28 of the patients. An external Fixator was applied for open fractures. Closed injuries were operated on 3 to 13 days after injury, with an average of 8 days. The mean follow-up was 48 months. All fractures united. The external fixator was removed after a mean of 22 weeks (10 - 28 weeks). Two patients with a type III fracture had a delayed union and were treated with corticotomy and dynamisation of the ILIZAROV fixator. Only one secondary displacement of a type III fracture was noted after two months and was treated by adjuction of 2 olive wires. There were no cases of osteomyelitis or deep infections. Pin-tract infections occurred in ten patients. We had not any case of nervous injury due to introduction of the pins. Using radiological criteria for assessement of reduction of the articular fragments, there was excellent and good restoration of articular structure in 24 cases. The average American Orthopeadic Foot and Ankle Society ankle-hind foot score was excellent in 16, good in 6, fair in 6 and poor in 2. Soft tissue healing occurred without need for plastic surgery in all cases. The movements of the ankle ranged from 0 to 20° of dorsiflexion and 5° to 40° of plantar flexion. Twenty patients had gone back to their preinjury profession. The ILIZAROV technique is a safe and a very effective treatment for severe pilon fractures with minimum complications and good healing results.

  2. Treatment of high-energy pilon fractures using the ILIZAROV treatment

    PubMed Central

    Osman, Walid; Alaya, Zeineb; Kaziz, Hamdi; Hassini, Lassad; Braiki, Meriem; Naouar, Nader; Ben Ayeche, Mohamed Laaziz

    2017-01-01

    The management of high-energy pilon fractures is still controversial. Open reduction and internal fixation are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. The aim of this retrospective study was to analyze the clinical and radiographic outcome of the ILIZAROV technique in patients with high-energy pilon fractures. Thirty cases of distal tibia epiphysis fractures (pilon fractures) were managed from 1999 to 2012. The study group included 5 cases of open fractures. The mean age was 47 years. According to Rüedi and Algower classification; 11 fractures were type II, and 19 type III. All fractures were a consequence of high-energy trauma. Fractures of the lower fibula were present in 28 of the patients. An external Fixator was applied for open fractures. Closed injuries were operated on 3 to 13 days after injury, with an average of 8 days. The mean follow-up was 48 months. All fractures united. The external fixator was removed after a mean of 22 weeks (10 - 28 weeks). Two patients with a type III fracture had a delayed union and were treated with corticotomy and dynamisation of the ILIZAROV fixator. Only one secondary displacement of a type III fracture was noted after two months and was treated by adjuction of 2 olive wires. There were no cases of osteomyelitis or deep infections. Pin-tract infections occurred in ten patients. We had not any case of nervous injury due to introduction of the pins. Using radiological criteria for assessement of reduction of the articular fragments, there was excellent and good restoration of articular structure in 24 cases. The average American Orthopeadic Foot and Ankle Society ankle-hind foot score was excellent in 16, good in 6, fair in 6 and poor in 2. Soft tissue healing occurred without need for plastic surgery in all cases. The movements of the ankle ranged from 0 to 20° of dorsiflexion and 5° to 40° of plantar flexion. Twenty patients had gone back to their preinjury profession. The ILIZAROV technique is a safe and a very effective treatment for severe pilon fractures with minimum complications and good healing results. PMID:28904724

  3. Arthroscopically assisted elbow interposition arthroplasty without hinged external fixation: surgical technique and patient outcomes.

    PubMed

    Chauhan, Aakash; Palmer, Bradley A; Baratz, Mark E

    2015-06-01

    Total elbow arthroplasty is successful in older, lower demand patients but not in the younger, more active individual with severe elbow arthritis. Interposition arthroplasty is an alternative for younger patients who hope to minimize the degree to which arm use is restricted. Interposition arthroplasty traditionally involves release of all ligaments and capsule. As a result, the postoperative care included the use of a hinged external fixator of the elbow to apply distraction and to permit motion during the early phases of healing. We describe a novel surgical technique without a hinged external fixator that allows secure fixation of the interposition graft through arthroscopic assistance and maintains the integrity of the medial collateral ligament with only a takedown and repair of the lateral collateral ligament complex. A retrospective chart review was performed to analyze 4 patients with an average age of 57 years who underwent surgery between 2007 and 2011. The patients were also contacted to assess elbow-specific American Shoulder and Elbow Surgeons and Disabilities of the Arm, Shoulder, and Hand scores. The average follow-up was 3.6 years (range, 2.5-6 years), and 1 patient was converted to a total elbow arthroplasty after 2.5 years because of persistent pain. The remaining 3 patients have done well with regard to pain control, stability, and functional use of the operative extremity. There were no postoperative complications. On the basis of our small series of patients, an arthroscopically assisted elbow interposition arthroplasty without hinged external fixation can provide satisfactory medium-term outcomes as a salvage procedure for a difficult condition with limited options. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Management of complex femoral nonunion with monorail external fixator: A prospective study.

    PubMed

    Agrawal, Hemendra Kumar; Garg, Mohit; Singh, Balvinder; Jaiman, Ashish; Khatkar, Vipin; Khare, Shailender; Batra, Sumit; Sharma, Vinod Kumar

    2016-01-01

    To evaluate 30 patients who underwent distraction osteogenesis with monorail external fixator for complex femoral nonunion. Complex femoral nonunion includes infective non-union, gap nonunion, and limb-length discrepancy secondary to traumatic bone loss, which needs specialized treatment to ensure the functional integrity of femoral bone. 30 patients, including 28 male and 2 female (aged 22-62 years) patients, underwent surgical debridement followed by bone transport with monorail fixator. The lengthening index, radiographic consolidation index, functional status, bone healing, and various problems, obstacles, and complications encountered during the treatment were assessed. Patients underwent a mean of 2.2 (range 1-4) surgeries before presentation. The mean bone defect after surgical debridement was 5.83 cm (range 2-16 cm). The mean treatment duration was 204.7 days (range 113-543 days). The mean lengthening index was 13.06 days/cm with range from 12 to 16 days/cm. Mean maturation index was 23.51 days/cm with range from 17 to 45.5 days/cm. In our study, bone result was excellent in 17, good in 9, fair in 3, and poor in 1 patient. In our study functional outcome is excellent in 9 [30%], good in 14 [46.67%], fair in 5, and poor in 2 patients. In our study, we encountered 34 problems, 17 obstacles, and 8 complications. We concluded that monorail external fixator is an effective treatment option for complex nonunion femoral shaft fracture and its functional outcome is comparable with any other treatment options. Lack of complications and its effectiveness makes monorail external fixator the treatment of choice for complex nonunion femoral shaft.

  5. The results of bone deformity correction using a spider frame with web-based software for lower extremity long bone deformities.

    PubMed

    Tekin, Ali Çağrı; Çabuk, Haluk; Dedeoğlu, Süleyman Semih; Saygılı, Mehmet Selçuk; Adaş, Müjdat; Esenyel, Cem Zeki; Büyükkurt, Cem Dinçay; Tonbul, Murat

    2016-03-22

    To present the functional and radiological results and evaluate the effectiveness of a computer-assisted external fixator (spider frame) in patients with lower extremity shortness and deformity. The study comprised 17 patients (14 male, 3 female) who were treated for lower extremity long bone deformity and shortness between 2012 and 2015 using a spider frame. The procedure's level of difficulty was determined preoperatively using the Paley Scale. Postoperatively, the results for the patients who underwent tibial operations were evaluated using the Paley criteria modified by ASAMI, and the results for the patients who underwent femoral operations were evaluated according to the Paley scoring system. The evaluations were made by calculating the External Fixator and Distraction indexes. The mean age of the patients was 24.58 years (range, 5-51 years). The spider frame was applied to the femur in 10 patients and to the tibia in seven. The mean follow-up period was 15 months (range, 6-31 months) from the operation day, and the mean amount of lengthening was 3.0 cm (range, 1-6 cm). The mean duration of fixator application was 202.7 days (range, 104-300 days). The mean External Fixator Index was 98 days/cm (range, 42-265 days/cm). The mean Distraction Index was 10.49 days/cm (range, 10-14 days/cm). The computer-assisted external fixator system (spider frame) achieves single-stage correction in cases of both deformity and shortness. The system can be applied easily, and because of its high-tech software, it offers the possibility of postoperative treatment of the deformity.

  6. A Surgical Procedure for Resecting the Mouse Rib: A Model for Large-Scale Long Bone Repair

    PubMed Central

    Funnell, John W.; Thein, Thu Zan Tun; Mariani, Francesca V.

    2015-01-01

    This protocol introduces researchers to a new model for large-scale bone repair utilizing the mouse rib. The procedure details the following: preparation of the animal for surgery, opening the thoracic body wall, exposing the desired rib from the surrounding intercostal muscles, excising the desired section of rib without inducing a pneumothorax, and closing the incisions. Compared to the bones of the appendicular skeleton, the ribs are highly accessible. In addition, no internal or external fixator is necessary since the adjacent ribs provide a natural fixation. The surgery uses commercially available supplies, is straightforward to learn, and well-tolerated by the animal. The procedure can be carried out with or without removing the surrounding periosteum, and therefore the contribution of the periosteum to repair can be assessed. Results indicate that if the periosteum is retained, robust repair occurs in 1 - 2 months. We expect that use of this protocol will stimulate research into rib repair and that the findings will facilitate the development of new ways to stimulate bone repair in other locations around the body. PMID:25651082

  7. Arthrodesis after failed knee arthroplasty. A nationwide multicenter investigation of 91 cases.

    PubMed

    Knutson, K; Hovelius, L; Lindstrand, A; Lidgren, L

    1984-12-01

    Ninety-one patients with attempted arthrodesis after failed knee arthroplasty were identified in a prospective nationwide study of knee arthroplasties performed from October 1975 through January 1982 in Sweden. The study included 43 hinged or stabilized, 34 bi- or tricompartment, and 14 unicompartment endoprostheses. Three-fourths of the failures were caused by infections. At follow-up evaluation, two patients had expired from infection and four patients had amputations. Fusion was achieved in only 50% of 108 attempts in 91 knees. Patients with unstable joints had limited function. The fusion rate was relatively high after unicompartment endoprostheses, in cases with sustained rigid fixation, or in cases where infection was brought under control at arthrodesis. Rigid fixation was best achieved with an external double frame or an intramedullary nail. Repeated attempts were worthwhile. Removal of all foreign material, eradication of the infectious lesion, and an arthrodesis performed in a one- or two-stage procedure with insertion of gentamicin beads seemed to be the best way to combat infection. The treatment of prosthetic failures should be referred to centers with special interest in knee arthroplasty.

  8. Screw-Wire Osteo-Traction: An Adjunctive or Alternative Method of Anatomical Reduction of Multisegment Midfacial Fractures? A Description of Technique and Prospective Study of 40 Patients

    PubMed Central

    O'Regan, Barry; Devine, Maria; Bhopal, Sats

    2013-01-01

    Stable anatomical fracture reduction and segment control before miniplate fixation can be difficult to achieve in comminuted midfacial fractures. Fracture mobilization and reduction methods include Gillies elevation, malar hook, and Dingman elevators. No single method is used universally. Disadvantages include imprecise segment alignment and poor segment stability/control. We have employed screw-wire osteo-traction (SWOT) to address this problem. A literature review revealed two published reports. The aims were to evaluate the SWOT technique effectiveness as a fracture reduction method and to examine rates of revision fixation and plate removal. We recruited 40 consecutive patients requiring open reduction and internal fixation of multisegment midfacial fractures (2009–2012) and employed miniplate osteosynthesis in all patients. SWOT was used as a default reduction method in all patients. The rates of successful fracture reduction achieved by SWOT alone or in combination and of revision fixation and plate removal, were used as outcome indices of the reduction method effectiveness. The SWOT technique achieved satisfactory anatomical reduction in 27/40 patients when used alone. Other reduction methods were also used in 13/40 patients. No patient required revision fixation and three patients required late plate removal. SWOT can be used across the midface fracture pattern in conjunction with other methods or as a sole reduction method before miniplate fixation. PMID:24436763

  9. Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury.

    PubMed

    Mohammed, R; Syed, S; Metikala, S; Ali, Sa

    2011-09-01

    With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures.

  10. Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury

    PubMed Central

    Mohammed, R; Syed, S; Metikala, S; Ali, SA

    2011-01-01

    Background: With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. Materials and Methods: 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. Results: At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. Conclusion: We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures. PMID:21886929

  11. Biomechanics of far cortical locking.

    PubMed

    Bottlang, Michael; Feist, Florian

    2011-02-01

    The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.

  12. Biomechanics of Far Cortical Locking

    PubMed Central

    Bottlang, Michael; Feist, Florian

    2011-01-01

    The development of FCL was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biological fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have shown to enhance fixation and fracture healing: Flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80–88% to actively promote callus proliferation similar to an external fixator. Load distribution is evenly shared between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by s-shaped flexion of FCL screws has shown to induce symmetric callus formation. In combination, these features of FCL constructs have shown to induce more callus and to yield significantly stronger and more consistent healing compared to standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biological healing response of external fixators. PMID:21248556

  13. A Novel Vesicoscopic Bladder Wall Suture Fixation Technique to Aid Endoscopic Vesicostomy Button Insertion

    PubMed Central

    Adam, Ahmed; Sookram, Jayveer

    2018-01-01

    Background To describe a novel bladder fixation technique for use during endoscopic vesicostomy button insertion. Methods After standard cystoscopic visualization of the bladder, a standard 18 G intravenous cannula was inserted into the bladder. A non-absorbable suture thread was placed through this intravenous cannula under cystoscopic vision. The proximal end of the suture was then removed using standard ureteroscopic grasping forceps (3 Fr) through another needle (15 G) inserted next to the initial puncture site (following a path at 30 degrees from the initial puncture tract) into the bladder. The suture ends were brought out of the bladder and tied at the skin level, 2 cm from the intended vesicostomy site. Sutures were removed on the second postoperative day. Results This fixation technique allows for adequate fixation of the bladder dome to the anterior abdominal wall. These sutures also have less potential for cutaneous scarring and pain. No complications were reported. Conclusion This simple fixation technique is easily performed using materials found in every urology suite. It also avoids the skills required with other previously reported fixation suture techniques, and can also be utilized for bladder fixation in cases of vesicoscopic laparoscopic or robotic assisted laparoscopic procedures. PMID:29692696

  14. Functional outcome of knee arthrodesis with a monorail external fixator.

    PubMed

    Roy, Alfred Cyril; Albert, Sandeep; Gouse, Mohamad; Inja, Dan Barnabas

    2016-04-01

    Several methods for obtaining knee arthrodesis have been described in the literature and world; over, the commonest cause for arthrodesis is a failed arthroplasty. Less commonly, as in this series, post-infective or traumatic causes may also require a knee fusion wherein arthroplasty may not be indicated. We present salient advantages along with the radiological and functional outcome of twenty four patients treated with a single monorail external fixator. All patients went on develop fusion at an average of 5.4 months with an average limb length discrepancy of 3 cm (1.5-6 cm). Improvements in functional outcome as assessed by the lower extremity functional score (LEFS), and the SF-36 was significant (p = 0.000). Knee arthrodesis with a single monorail external fixator is a reasonable single-staged salvage option in patients wherein arthroplasty may not be the ideal choice. The outcome, though far from ideal, is definitely positive and predictable.

  15. Evaluation and management of injuries of the tibiofibular syndesmosis.

    PubMed

    Magan, Ahmed; Golano, Pau; Maffulli, Nicola; Khanduja, Vikas

    2014-09-01

    Injury to the tibiofibular syndesmosis often arises from external rotation force acting on the foot leading to eversion of the talus within the ankle mortise and increased dorsiflexion or plantar flexion. Such injuries can present in the absence of a fracture. Therefore, diagnosis of these injuries can be challenging, and often stress radiographs are helpful. Magnetic resonance imaging scans can be a useful adjunct in doubtful cases. The management of syndesmotic injuries remains controversial, and there is no consensus on how to optimally fix syndesmosis. This article reviews the mechanism of injury, clinical features and investigations performed for syndesmotic injuries and brings the reader up-to-date with the current evidence in terms of the controversies surrounding the management of these injuries. Embase, Pubmed Medline, Cochrane Library, Elsevier and Google Scholar (January 1950-2014). The management of syndesmotic injuries remains controversial, and there is no consensus on: (i) which ankle fractures require syndesmotic fixation, (ii) the number or the size and the type of screws that should be used for fixation, (iii) how many cortices to engage for fixation, (iv) the level of screw placement above the ankle plafond, (v) the duration for which the screw needs to remain in situ to allow the tibiofibular syndesmosis to heal and (vi) when should patients weight bear. (i) A high proportion of syndesmotic fixations demonstrates malreduction of the syndesmosis, (ii) no need to remove screws routinely, (iii) two screws appear to better one alone and (iv) if syndesmosis injury is not detected or not treated long term, it leads to pain and arthritis. (i) How to assess the adequacy of syndesmotic reduction using imaging in the peri-operative period, (ii) the use of bio-absorbable materials and Tightrope and (iii) evidence is emerging not to remove syndesmotic screws unless symptomatic. (i) A bio-absorbable material that can be used to fix the syndesmosis and allow early weight bearing, and (ii) there is a need for developing a surgical technique for adequately reducing the syndesmosis without the exposure to radiation. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Humeral lengthening and proximal deformity correction with monorail external fixator in young adults.

    PubMed

    Ruan, Hongjiang; Zhu, Yi; Liu, Shen; Kang, Qinglin

    2018-05-01

    Several humeral lengthening or simultaneous deformity corrections through one osteotomy using various external fixators were reported, while literature regarding correction of shortening and proximal varus deformity is scarce. This retrospective clinical study evaluated the results of preforming an acute correction and delayed lengthening in young adults through two osteotomies using monorail external fixator. We report seven patients with various pathologies who underwent humeral proximal deformity correction and lengthening between 2009 and 2015. Pre-operative and post-operative clinical and radiographic data were collected. The mean follow-up time was 33.4 months (25-46 months). The humeral neck-shaft angle improved from 97.9° (85-110°) to 138.6° (135-145°). The magnitude of lengthening achieved was average 7.6 cm (range, 6-10 cm) at an average healing index of lengthening of 30.2 days/cm (range, 27.7-35.4 days/cm). There was a significant increase in range of shoulder abduction, and active abduction improved from pre-operative 136.4° (range, 95-160°) to post-operative 166.4° (range, 150-180°). The DASH score improved significance from 23.29 ± 8.36 to 6.57 ± 3.65 (t = 4.848; p < 0.001). Acute deformity correction and gradual lengthening with the monorail external fixator can be used for humeral shortening and proximal varus angular deformity. Functional improvement is expected after surgery and post-operative therapy.

  17. Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis

    PubMed Central

    Vaidya, Rahul; Onwudiwe, Ndidi; Roth, Matthew; Sethi, Anil

    2013-01-01

    Purpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic range, 2 to torsional failure and 3 in distraction until failure. Results. The pedicle screw systems showed higher stiffness (4.008 ± 0.113 Nmm monoaxial, 3.638 ± 0.108 Nmm Click-x; 3.634 ± 0.147 Nmm Pangea) than the exfix system (2.882 ± 0.054 Nmm) in distraction. In failure testing, monoaxial pedicle screw system was stronger (360 N) than exfixes (160 N) and polyaxial devices which failed if distracted greater than 4 cm (157 N Click-x or 138 N Pangea). The exfix had higher peak torque and torsional stiffness than all pedicle systems. In torsion, the yield strengths were the same for all constructs. Conclusion. The infix device constructed with polyaxial or monoaxial pedicle screws is stiffer than the 2 pin external fixator in distraction testing. In extreme cases, the use of reinforcement or monoaxial systems which do not fail even at 360 N is a better option. In torsional testing, the 2 pin external fixator is stiffer than the pedicle screw systems. PMID:24368943

  18. Monoaxial pedicle screws are superior to polyaxial pedicle screws and the two pin external fixator for subcutaneous anterior pelvic fixation in a biomechanical analysis.

    PubMed

    Vaidya, Rahul; Onwudiwe, Ndidi; Roth, Matthew; Sethi, Anil

    2013-01-01

    Purpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic range, 2 to torsional failure and 3 in distraction until failure. Results. The pedicle screw systems showed higher stiffness (4.008 ± 0.113 Nmm monoaxial, 3.638 ± 0.108 Nmm Click-x; 3.634 ± 0.147 Nmm Pangea) than the exfix system (2.882 ± 0.054 Nmm) in distraction. In failure testing, monoaxial pedicle screw system was stronger (360 N) than exfixes (160 N) and polyaxial devices which failed if distracted greater than 4 cm (157 N Click-x or 138 N Pangea). The exfix had higher peak torque and torsional stiffness than all pedicle systems. In torsion, the yield strengths were the same for all constructs. Conclusion. The infix device constructed with polyaxial or monoaxial pedicle screws is stiffer than the 2 pin external fixator in distraction testing. In extreme cases, the use of reinforcement or monoaxial systems which do not fail even at 360 N is a better option. In torsional testing, the 2 pin external fixator is stiffer than the pedicle screw systems.

  19. Mechanical evaluation of external skeletal fixator-intramedullary pin tie-in configurations applied to cadaveral humeri from red-tailed hawks (Buteo jamaicensis).

    PubMed

    Van Wettere, Arnaud J; Redig, Patrick T; Wallace, Larry J; Bourgeault, Craig A; Bechtold, Joan E

    2009-12-01

    Use of external skeletal fixator-intramedullary pin (ESF-IM) tie-in fixators is an adjustable and effective method of fracture fixation in birds. The objective of this study was to determine the contribution of each of the following parameters to the compressive and torsional rigidity of an ESF-IM pin tie-in applied to avian bones with an osteotomy gap: (1) varying the fixation pin position in the proximal bone segment and (2) increasing the number of fixation pins in one or both bone segments. ESF-IM pin tie-in constructs were applied to humeri harvested from red-tailed hawks (Buteo jamaicensis) (n=24) that had been euthanatized for clinical reasons. Constructs with a variation in the placement of the proximal fixation pin and with 2, 3, or 4 fixation pins applied to avian bone with an osteotomy gap were loaded to a defined displacement in torque and axial compression. Response variables were determined from resulting load-displacement curves (construct stiffness, load at 1-mm displacement). Increasing the number of fixation pins from 1 to 2 per bone segment significantly increased the stiffness in torque (110%) and compression (60%), and the safe load in torque (107%) and compression (50%). Adding a fixation pin to the distal bone segment to form a 3-pin fixator significantly increased the stiffness (27%) and safe load (20%) in torque but not in axial compression. In the configuration with 2 fixation pins, placing the proximal pin distally in the proximal bone segment significantly increased the stiffness in torque (28%), and the safe load in torque (23%) and in axial compression (32%). Results quantified the relative importance of specific parameters affecting the rigidity of ESF-IM pin tie-in constructs as applied to unstable bone fracture models in birds.

  20. Characterization of interfragmentary motion associated with common osteosynthesis devices for rat fracture healing studies.

    PubMed

    Meyers, Nicholaus; Sukopp, Matthias; Jäger, Rudolf; Steiner, Malte; Matthys, Romano; Lapatki, Bernd; Ignatius, Anita; Claes, Lutz

    2017-01-01

    Rat models are widely used in preclinical studies investigating fracture healing. The interfragmentary movement at a fracture site is critical to the course of healing and therefore demands definition in order to aptly interpret the experimental results. Estimation of this movement requires knowledge of the fixation stiffness and loading. The characteristic loading for the rat femur has been estimated, but the stiffness of fixation used in rat studies has yet to be fully described. This study aimed to determine the 6 degree of freedom stiffness of four commonly used implants, two external fixators (RatExFix and UlmExFix), a locking plate, and a locking intramedullary nail, in all degrees of freedom and estimate the interfragmentary movement under specific physiological loads. The external fixator systems allow the greatest movement. Mounted 45° anterolateral on the femur, the RatExFix allows an average of 0.88 mm of motion in each anatomic direction while the stiffer UlmExFix allows about 0.6 mm of motion. The nail is far stiffer than the other implants investigated while the plate allows movement of an intermediate magnitude. Both the nail and plate demonstrate higher axial than shear stiffness. The relatively large standard deviations in external fixator shear motion imply strong dependence on bone axis alignment across the gap and the precise orientation of the specimen relative to the loading. The smaller standard deviation associated with the nail and plate results from improved alignment and minimization of the influence of rotational positioning of the specimen due to the reduced implant eccentricity relative to the specimen axis. These results show that the interfragmentary movement is complex and varies significantly between fixation devices but establishes a baseline for the evaluation of the results of different studies.

  1. Characterization of interfragmentary motion associated with common osteosynthesis devices for rat fracture healing studies

    PubMed Central

    Steiner, Malte; Matthys, Romano; Lapatki, Bernd; Ignatius, Anita; Claes, Lutz

    2017-01-01

    Rat models are widely used in preclinical studies investigating fracture healing. The interfragmentary movement at a fracture site is critical to the course of healing and therefore demands definition in order to aptly interpret the experimental results. Estimation of this movement requires knowledge of the fixation stiffness and loading. The characteristic loading for the rat femur has been estimated, but the stiffness of fixation used in rat studies has yet to be fully described. This study aimed to determine the 6 degree of freedom stiffness of four commonly used implants, two external fixators (RatExFix and UlmExFix), a locking plate, and a locking intramedullary nail, in all degrees of freedom and estimate the interfragmentary movement under specific physiological loads. The external fixator systems allow the greatest movement. Mounted 45° anterolateral on the femur, the RatExFix allows an average of 0.88 mm of motion in each anatomic direction while the stiffer UlmExFix allows about 0.6 mm of motion. The nail is far stiffer than the other implants investigated while the plate allows movement of an intermediate magnitude. Both the nail and plate demonstrate higher axial than shear stiffness. The relatively large standard deviations in external fixator shear motion imply strong dependence on bone axis alignment across the gap and the precise orientation of the specimen relative to the loading. The smaller standard deviation associated with the nail and plate results from improved alignment and minimization of the influence of rotational positioning of the specimen due to the reduced implant eccentricity relative to the specimen axis. These results show that the interfragmentary movement is complex and varies significantly between fixation devices but establishes a baseline for the evaluation of the results of different studies. PMID:28453556

  2. Numerical investigations of MRI RF field induced heating for external fixation devices

    PubMed Central

    2013-01-01

    Background The magnetic resonance imaging (MRI) radio frequency (RF) field induced heating on external fixation devices can be very high in the vicinity of device screws. Such induced RF heating is related to device constructs, device placements, as well as the device insertion depth into human subjects. In this study, computational modeling is performed to determine factors associated with such induced heating. Methods Numerical modeling, based on the finite-difference time-domain (FDTD) method, is used to evaluate the temperature rises near external device screw tips inside the ASTM phantom for both 1.5-T and 3-T MRI systems. The modeling approach consists of 1) the development of RF coils for 1.5-T and 3-T, 2) the electromagnetic simulations of energy deposition near the screw tips of external fixation devices, and 3) the thermal simulations of temperature rises near the tips of these devices. Results It is found that changing insertion depth and screw spacing could largely affect the heating of these devices. In 1.5-T MRI system, smaller insertion depth and larger pin spacing will lead to higher temperature rise. However, for 3-T MRI system, the relation is not very clear when insertion depth is larger than 5 cm or when pin spacing became larger than 20 cm. The effect of connection bar material on device heating is also studied and the heating mechanism of the device is analysed. Conclusions Numerical simulation is used to study RF heating for external fixation devices in both 1.5-T and 3-T MRI coils. Typically, shallower insertion depth and larger pin spacing with conductive bar lead to higher RF heating. The heating mechanism is explained using induced current along the device and power decay inside ASTM phantom. PMID:23394173

  3. Asymmetry in gait pattern following bicondylar tibial plateau fractures-A prospective one-year cohort study.

    PubMed

    Elsoe, Rasmus; Larsen, Peter

    2017-07-01

    Despite the high number of studies evaluating outcomes following tibial plateau fractures, the literature lacks studies including the objective assessment of gait pattern. The purpose of the present study was to evaluate asymmetry in gait patterns at 12 months after frame removal following ring fixation of a tibial plateau fracture. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns 12 months after frame removal measured with a pressure-sensitive mat. The mat registers footprints and present gait speed, cadence, as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. Twenty-three patients were included with a mean age of 54.4 years (32-78 years). Patients presented with a shorter step-length of the injured leg compared to the non-injured leg (asymmetry of 11.3%). Analysis of single-support showed shorter support time of the injured leg compared to the non-injured leg (asymmetry of 8.7%). Moreover, analysis of swing-time showed increased swing-time of the injured leg (asymmetry of 8.9%). Compared to a healthy reference population, increased asymmetry in all gait patterns was observed. The association between asymmetry and health-related quality of life (HRQOL) showed moderate associations (single-support: R=0.50, P=0.03; step-length: R=0.43, P=0.07; swing-time: R=0.46, P=0.05). Compared to a healthy reference population, gait asymmetry is common 12 months after frame removal in patients treated with external ring fixation following a tibial plateau fracture of the tibia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing.

    PubMed

    Gessmann, Jan; Königshausen, Matthias; Coulibaly, Marlon Osman; Schildhauer, Thomas Armin; Seybold, Dominik

    2016-05-01

    Humeral shaft nonunion after intramedullary nailing is a rare but serious complication. Treatment options include implant removal, open plating, exchange nailing and external fixation. The objective of this retrospective study was to determine whether augmentation plating without nail removal is feasible for treating a humeral shaft nonunion. Between 2002 and 2014, 37 patients (mean age 51, range 20-84 years) with aseptic humeral shaft nonunions prior to intramedullary nailing were treated with augmentation plating. The initial fractures had been fixed with retrograde nails (10 cases) or anterograde nails (27 cases). There were 34 atrophic nonunions and 3 hypertrophic nonunions. Nonunion treatment of all patients consisted of local debridement through an anterior approach to the humerus and anterior placement of the augmentation plates. Supplemental bone grafting was performed in all atrophic nonunion cases. All patients were followed until union was radiologically confirmed. Union was achieved in 36 patients (97 %) after a mean of 6 months (range 3-24 months). There was one case of iatrogenic median nerve palsy that showed complete spontaneous recovery 6 weeks postoperatively. One patient sustained a peri-implant stress fracture that was treated successfully by exchanging the augmentation plate to bridge the nonunion and the fracture. No infections or wound healing complications developed. At a mean follow-up of 14 months, all patients showed free shoulder and elbow motion and no restrictions in daily or working life. The results indicate that augmentation plating using an anterior approach is a safe and reliable option for humeral shaft nonunions after failed nailing, and the treatment has no substantial complications. Because the healing rates are similar to the standard technique of nail removal and fixation by compression or locking plates, we consider this technique to be an alternative choice for treatment.

  5. Efficacy of Retrievable Metallic Stent with Fixation String for Benign Stricture after Upper Gastrointestinal Surgery.

    PubMed

    Kim, Jeong-Eun; Kim, Hyo-Cheol; Lee, Myungsu; Hur, Saebeom; Kim, Minuk; Lee, Sang Hwan; Cho, Soo Buem; Kim, Chan Sun; Han, Joon Koo

    2016-01-01

    To determine the efficacy of retrievable metallic stent with fixation string for benign anastomotic stricture after upper gastrointestinal (UGI) surgery. From June 2009 to May 2015, a total of 56 retrievable metallic stents with fixation string were placed under fluoroscopy guidance in 42 patients who were diagnosed with benign anastomotic stricture after UGI surgery. Clinical success was defined as achieving normal regular diet (NRD). The clinical success rate after the first stent placement was 57.1% (24/42). After repeated stent placement and/or balloon dilation, the clinical success rate was increased to 83.3% (35/42). Six (14.3%) patients required surgical revision to achieve NRD. One (2.4%) patient failed to achieve NRD. Stent migration occurred in 60.7% (34/56) of patients. Successful rate of removing the stent using fixation string and angiocatheter was 94.6% (53/56). Distal migration occurred in 12 stents. Of the 12 stents, 10 (83.3%) were successfully removed whereas 2 could not be removed. No complication occurred regarding distal migration. Using retrievable metallic stent with a fixation string is a feasible option for managing early benign anastomotic stricture after UGI surgery. It can reduce complications caused by distal migration of the stent.

  6. Efficacy of Retrievable Metallic Stent with Fixation String for Benign Stricture after Upper Gastrointestinal Surgery

    PubMed Central

    Kim, Jeong-Eun; Lee, Myungsu; Hur, Saebeom; Kim, Minuk; Lee, Sang Hwan; Cho, Soo Buem; Kim, Chan Sun; Han, Joon Koo

    2016-01-01

    Objective To determine the efficacy of retrievable metallic stent with fixation string for benign anastomotic stricture after upper gastrointestinal (UGI) surgery. Materials and Methods From June 2009 to May 2015, a total of 56 retrievable metallic stents with fixation string were placed under fluoroscopy guidance in 42 patients who were diagnosed with benign anastomotic stricture after UGI surgery. Clinical success was defined as achieving normal regular diet (NRD). Results The clinical success rate after the first stent placement was 57.1% (24/42). After repeated stent placement and/or balloon dilation, the clinical success rate was increased to 83.3% (35/42). Six (14.3%) patients required surgical revision to achieve NRD. One (2.4%) patient failed to achieve NRD. Stent migration occurred in 60.7% (34/56) of patients. Successful rate of removing the stent using fixation string and angiocatheter was 94.6% (53/56). Distal migration occurred in 12 stents. Of the 12 stents, 10 (83.3%) were successfully removed whereas 2 could not be removed. No complication occurred regarding distal migration. Conclusion Using retrievable metallic stent with a fixation string is a feasible option for managing early benign anastomotic stricture after UGI surgery. It can reduce complications caused by distal migration of the stent. PMID:27833405

  7. RELATIONSHIP BETWEEN RIGIDITY OF EXTERNAL FIXATOR AND NUMBER OF PINS: COMPUTER ANALYSIS USING FINITE ELEMENTS

    PubMed Central

    Sternick, Marcelo Back; Dallacosta, Darlan; Bento, Daniela Águida; do Reis, Marcelo Lemos

    2015-01-01

    Objective: To analyze the rigidity of a platform-type external fixator assembly, according to different numbers of pins on each clamp. Methods: Computer simulation on a large-sized Cromus dynamic external fixator (Baumer SA) was performed using a finite element method, in accordance with the standard ASTM F1541. The models were generated with approximately 450,000 quadratic tetrahedral elements. Assemblies with two, three and four Schanz pins of 5.5 mm in diameter in each clamp were compared. Every model was subjected to a maximum force of 200 N, divided into 10 sub-steps. For the components, the behavior of the material was assumed to be linear, elastic, isotropic and homogeneous. For each model, the rigidity of the assembly and the Von Mises stress distribution were evaluated. Results: The rigidity of the system was 307.6 N/mm for two pins, 369.0 N/mm for three and 437.9 N/mm for four. Conclusion: The results showed that four Schanz pins in each clamp promoted rigidity that was 19% greater than in the configuration with three pins and 42% greater than with two pins. Higher tension occurred in configurations with fewer pins. In the models analyzed, the maximum tension occurred on the surface of the pin, close to the fixation area. PMID:27047879

  8. Knee arthrodesis with the Sheffield external ring fixator: fusion in 6 of 10 consecutive patients.

    PubMed

    Ulstrup, Anton K; Folkmar, Klaus; Broeng, Leif

    2007-06-01

    Knee arthrodesis with external fixation (XF) is a possible salvage procedure for infected total knee arthroplasties (TKA). We report the outcome in 10 patients who underwent arthrodesis with the Sheffield Ring Fixator. The patients had primary arthrosis in 8 cases; 2 cases were due to rheumatoid arthritis and sclerodermia. The mean time between the primary TKA and arthrodesis was 6 (0.5-14) years. The average age at arthrodesis was 69 years. The average follow-up period was 10 months. Stable fusion was obtained in 6 patients after a mean XF time of 3.6 (2-4) months. 1 patient was referred to another hospital because of nonunion. This patient showed fusion with intramedullary nailing after 7 months. 3 nonunion patients required permanent bracing. 7 patients had pin tract infections. Infections healed in all patients. The Sheffield Ring Fixator gives an acceptable fusion rate for arthrodesis in the infected TKA, with limited complications.

  9. Determination of ankle external fixation stiffness by expedited interactive finite element analysis.

    PubMed

    Nielsen, Jonathan K; Saltzman, Charles L; Brown, Thomas D

    2005-11-01

    Interactive finite element analysis holds the potential to quickly and accurately determine the mechanical stiffness of alternative external fixator frame configurations. Using as an example Ilizarov distraction of the ankle, a finite element model and graphical user interface were developed that provided rapid, construct-specific information on fixation rigidity. After input of specific construct variables, the finite element software determined the resulting tibial displacement for a given configuration in typically 15s. The formulation was employed to investigate constructs used to treat end-stage arthritis, both in a parametric series and for five specific clinical distraction cases. Parametric testing of 15 individual variables revealed that tibial half-pins were much more effective than transfixion wires in limiting axial tibial displacement. Factors most strongly contributing to stiffening the construct included placing the tibia closer to the fixator rings, and mounting the pins to the rings at the nearest circumferential location to the bone. Benchtop mechanical validation results differed inappreciably from the finite element computations.

  10. [Arthroscopic knee arthrodesis: 4 cases].

    PubMed

    Acquitter, Y; Hulet, C; Souquet, D; Pierre, A; Locker, B; Vielpeau, C

    2004-02-01

    Arthroscopic arthrodesis of the knee joint is an alternative to classical surgery, which retains a few exceptional indications. We report the first four cases of our experience, describing the technical modalities and indications. The four patients had undergone multiple operations for severe trauma. All four had persistent severe pain with a very limited walking distance. Before the procedure, the IKS score ranged from 11 to 44 and the mean function score was 20 to 45 points. Arthroscopic arthrodesis was proposed after several consultations and took into account the young age of the patient and a positive brace test. The successive arthroscopic times were: exploration and adherence release, complete extramural meniscectomy, joint surface avivement. Traction was not necessary. Careful avivement spared the anatomic curvatures of the condyles and slightly scraped out the plateaus. Finally, the arthrodesis was fixed in correct position under fluoroscopy using a single tube external fixator. The fixation was maintained until fusion (satisfactory x-ray and no pain). A drain was inserted only for the first patient. There were no cutaneous complications. Patients were discharged after 3 days on the average with immediate simulated weight bearing using two crutches. The external fixator was dynamized at two months (mean) and removed at five months. The functional gain was considerable in four patients, assessed at two years, with a mean IKS score of 75 and a mean function score of 80. The four patients walked without crutches and without pain. Single leg stance was stable. Final leg shortening was 1 to 2 cm. The arthroscopic approach provides several benefits: uneventful postoperative period, little bleeding, no cutaneous complications, shorter hospital stay. The time to fusion appears to be shorter than with classical techniques, but cannot be demonstrated clearly because of the diversity of the series reported in the literature. Arthroscopic arthrodesis does not require any special instruments, but does require surgical skill and a lengthy procedure. When arthrodesis is required the arthroscopic procedure is indicated for minimally deformed knees without major loss of bone stock.

  11. Fracture healing using degradable magnesium fixation plates and screws.

    PubMed

    Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Noorani, Sabrina; Costello, Bernard J; Sfeir, Charles

    2015-02-01

    Internal bone fixation devices made with permanent metals are associated with numerous long-term complications and may require removal. We hypothesized that fixation devices made with degradable magnesium alloys could provide an ideal combination of strength and degradation, facilitating fracture fixation and healing while eliminating the need for implant removal surgery. Fixation plates and screws were machined from 99.9% pure magnesium and compared with titanium devices in a rabbit ulnar fracture model. Magnesium device degradation and the effect on fracture healing and bone formation were assessed after 4 weeks. Fracture healing with magnesium device fixation was compared with that of titanium devices using qualitative histologic analysis and quantitative histomorphometry. Micro-computed tomography showed device degradation after 4 weeks in vivo. In addition, 2-dimensional micro-computed tomography slices and histologic staining showed that magnesium degradation did not inhibit fracture healing or bone formation. Histomorphology showed no difference in bone-bridging fractures fixed with magnesium and titanium devices. Interestingly, abundant new bone was formed around magnesium devices, suggesting a connection between magnesium degradation and bone formation. Our results show potential for magnesium fixation devices in a loaded fracture environment. Furthermore, these results suggest that magnesium fixation devices may enhance fracture healing by encouraging localized new bone formation. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Outcome of limb fracture repair in rabbits: 139 cases (2007-2015).

    PubMed

    Sasai, Hiroshi; Fujita, Daisuke; Seto, Eiko; Denda, Yuki; Imai, Yutaro; Okamoto, Kanako; Okamura, Kensaku; Furuya, Masaru; Tani, Hiroyuki; Sasai, Kazumi

    2018-02-15

    OBJECTIVE To evaluate outcome of limb fracture repair in rabbits. DESIGN Retrospective case series. ANIMALS 139 client-owned rabbits with limb fractures treated between 2007 and 2015. PROCEDURES Medical records were reviewed for information on fracture location, fracture treatment, and time to fracture healing. RESULTS 25 rabbits had fractures involving the distal aspects of the limbs (ie, metacarpal or metatarsal bones, phalanges, and calcaneus or talus). Fractures were treated in 23 of these 25 rabbits (external coaptation, n = 17; external skeletal fixation, 4; and intramedullary pinning, 2) and healed in all 23, with a median healing time of 28 days (range, 20 to 45 days). One hundred ten rabbits had long bone fractures, and fractures were treated in 100 of the 110 (external skeletal fixation, n = 89; bone plating, 1; intramedullary pinning, 3; and external coaptation, 7). The percentage of fractures that healed was significantly lower for open (14/18) than for closed (26/26) tibial fractures and was significantly lower for femoral (19/26) and treated humeral (4/6) fractures than for radial (23/24) or closed tibial (26/26) fractures. Micro-CT was used to assess fracture realignment during external skeletal fixator application and to evaluate fracture healing. CONCLUSIONS AND CLINICAL RELEVANCE The prognosis for rabbits with limb fractures was good, with fractures healing in most rabbits following fracture repair (109/123). Micro-CT was useful in assessing fracture realignment and evaluating fracture healing.

  13. Evolutionary games on cycles with strong selection

    NASA Astrophysics Data System (ADS)

    Altrock, P. M.; Traulsen, A.; Nowak, M. A.

    2017-02-01

    Evolutionary games on graphs describe how strategic interactions and population structure determine evolutionary success, quantified by the probability that a single mutant takes over a population. Graph structures, compared to the well-mixed case, can act as amplifiers or suppressors of selection by increasing or decreasing the fixation probability of a beneficial mutant. Properties of the associated mean fixation times can be more intricate, especially when selection is strong. The intuition is that fixation of a beneficial mutant happens fast in a dominance game, that fixation takes very long in a coexistence game, and that strong selection eliminates demographic noise. Here we show that these intuitions can be misleading in structured populations. We analyze mean fixation times on the cycle graph under strong frequency-dependent selection for two different microscopic evolutionary update rules (death-birth and birth-death). We establish exact analytical results for fixation times under strong selection and show that there are coexistence games in which fixation occurs in time polynomial in population size. Depending on the underlying game, we observe inherence of demographic noise even under strong selection if the process is driven by random death before selection for birth of an offspring (death-birth update). In contrast, if selection for an offspring occurs before random removal (birth-death update), then strong selection can remove demographic noise almost entirely.

  14. Biomechanical evaluation of the impact of various facet joint lesions on the primary stability of anterior plate fixation in cervical dislocation injuries: a cadaver study: Laboratory investigation.

    PubMed

    Oberkircher, Ludwig; Born, Sebastian; Struewer, Johannes; Bliemel, Christopher; Buecking, Benjamin; Wack, Christina; Bergmann, Martin; Ruchholtz, Steffen; Krüger, Antonio

    2014-10-01

    Injuries of the subaxial cervical spine including facet joints and posterior ligaments are common. Potential surgical treatments consist of anterior, posterior, or anterior-posterior fixation. Because each approach has its advantages and disadvantages, the best treatment is debated. This biomechanical cadaver study compared the effect of different facet joint injuries on primary stability following anterior plate fixation. Fractures and plate fixation were performed on 15 fresh-frozen intact cervical spines (C3-T1). To simulate a translation-rotation injury in all groups, complete ligament rupture and facet dislocation were simulated by dissecting the entire posterior and anterior ligament complex between C-4 and C-5. In the first group, the facet joints were left intact. In the second group, one facet joint between C-4 and C-5 was removed and the other side was left intact. In the third group, both facet joints between C-4 and C-5 were removed. The authors next performed single-level anterior discectomy and interbody grafting using bone material from the respective thoracic vertebral bodies. An anterior cervical locking plate was used for fixation. Continuous loading was performed using a servohydraulic test bench at 2 N/sec. The mean load failure was measured when the implant failed. In the group in which both facet joints were intact, the mean load failure was 174.6 ± 46.93 N. The mean load failure in the second group where only one facet joint was removed was 127.8 ± 22.83 N. In the group in which both facet joints were removed, the mean load failure was 73.42 ± 32.51 N. There was a significant difference between the first group (both facet joints intact) and the third group (both facet joints removed) (p < 0.05, Kruskal-Wallis test). In this cadaver study, primary stability of anterior plate fixation for dislocation injuries of the subaxial cervical spine was dependent on the presence of the facet joints. If the bone in one or both facet joints is damaged in the clinical setting, anterior plate fixation in combination with bone grafting might not provide sufficient stabilization; additional posterior stabilization may be needed.

  15. [Case-control study on T-shaped locking internal fixation and external fixation for the treatment of dorsal Barton's fracture].

    PubMed

    Chen, Huan-qing; Wen, Xi-le; Li, Yang-ming; Wen, Cong-you

    2015-06-01

    To compare clinical effect of T-shaped locking internal fixation and external fixation in treating dorsal Barton's fracture,and investigate selective strategy of internal fixation. From January 2008 to January 2013, 100 patients with dorsal Barton's fracture were randomly divided into two groups. In treatment group, there were 30 males and 20 females with an average age of (33.8±3.6) years old;30 cases were type B, 20 cases were type C;and treated with T-shaped locking internal fixation. In control group, there were 32 male and 18 females with an average age of (32.9±3.4) years old; 29 cases were type B, 21 cases were type C; and treated with external fixation. Volar tilt, ulnar deviation and radial height at 3 months after operation were detected and compared between two groups. Mechara functional evaluation were used to evaluate postoperative clinical effects. Clinical cure time, postoperative complications,joint mobility and function score were recorded and compared between two groups. In treatment group,volar tilt was (11.9±2.7)°, ulnar deviation was (20.8+ 2.9)°,and radial height was (10.9±1.8) mm; while volar tilt was (9.1±1.6)°, ulnar deviation was (17.1±2.9)°, and radial height was (8.1±1.5) mm in control group. Treatment group was better than control group in volar tilt, ulnar deviation and radial height. Clinical cure time in treatment group was(12.0±2.3) weeks, shorter than control group (18.0±4.1) weeks. The incidence of complications in treatment group was lower than control group. According to Mehara functional evaluation,20 cases got excellent results, 25 good, 3 moderate and 2 poor in treatment group; 16 cases got excellent results, 14 good, 10 moderate and 10 poor in control group. Treatment group was better than control group in clinical effects. T-shaped locking internal fixation with postoperative functional exercise for the treatment of dorsal Barton's fracture fits for biomechanics demands,and has advantages of stable fixation,rapid recovery, less complications and good functional recovery, it has better clinical effects.

  16. Surface fixation of dried blood by glutaraldehyde and peracetic acid.

    PubMed

    Kampf, G; Bloss, R; Martiny, H

    2004-06-01

    The difficulties of successful prion inactivation by chemical agents has led to changes in recommendations regarding the reprocessing of instruments including flexible endoscopes. One of the changes is the preference for peracetic acid instead of glutaraldehyde in order to avoid fixation of organic material, but the surface fixation by various active agents has not been fully investigated. We used a standardized amount of dried blood soil on metal carriers (on average 22 mg). One part of the carriers was exposed to different disinfectants (four based on peracetic acid, three based on glutaraldehyde, two based on quaternary ammonium compounds (QAC), one based on QAC and amines, one based on phenols and one cleaning agent) and air dried. The difference compared with the non-exposed soiled carrier was taken as the measure of blood removal by exposure to the disinfectants. In addition the other part of the carriers was exposed to a cleaning agent and air dried. The cleaning agent itself was capable of removing more than 99% of the dried blood and served as a control for non-fixation. The rate of fixation of dried blood was calculated as the ratio of the weight of residual soil on 'soiled, disinfected and cleaned' carriers and on 'soiled and disinfected' carriers. All experiments were repeated eight times. Blood removal varied between 90.3% +/- 1.5% (phenol-based disinfectant) and < 10% (glutaraldehyde-based preparations). Fixation of the remainder was between 76.9 +/- 8.4% and 102.5 +/- 1.1% with glutaraldehyde and between 19.2% +/- 3.3% and 78.1% +/- 2.4% with peracetic acid. No other preparations showed a potential for blood fixation (< 1.3%). Our findings underline the potential for blood fixation, not only by glutaraldehyde, but also by peracetic acid, and support the evidence that effective cleaning should precede the chemical disinfection. Copyright 2004 The Hospital Infection Society

  17. Graft-supplemented, augmented external fixation in the treatment of intra-articular distal radial fractures.

    PubMed

    Tyllianakis, Minos E; Panagopoulos, Andreas; Giannikas, Dimitrios; Megas, Panagiotis; Lambiris, Elias

    2006-02-01

    This article compares the functional and radiographic outcomes of intraarticular distal radial fractures treated with augmented external fixation in which autologous cancellous bone grafting or Norian SRS (Norian Corp, Cupertino, Calif) was used for filling the metaphyseal void. Thirty non-randomized patients, 15 in each group, with AO type C distal radius fractures (20 men and 10 women; average age: 48 years) were operatively treated between 1998-2000 and retrospectively evaluated. Radial inclination, radial length, volar tilt, and Modified Mayo Wrist Score were assessed at the most recent follow-up evaluation (average: 33.3 months). Overall, 12 (80%) patients in the Norian group had an excellent or good result, 2 had fair, and 1 had poor. In the autologous iliac bone graft group, the results were excellent or good in 11 (73.3%) patients, fair in 1, and poor in 2. No statistical difference between the two types of grafting was noted. Norian SRS is equally effective to cancellous bone as supplementary graft in comminuted distal radial fractures treated by external and Kirschner-wire fixation.

  18. Conversion of external fixation to open reduction and internal fixation for complex distal radius fractures.

    PubMed

    Natoli, R M; Baer, M R; Bednar, M S

    2016-05-01

    Distal radius fractures are common injuries treated in a multitude of ways. One treatment paradigm not extensively studied is initial treatment by external fixation (EF) followed by conversion to open reduction internal fixation (ORIF). Such a paradigm may be beneficial in damage control situations, when there is extensive soft tissue injury, or when appropriate personnel/hospital resources are not available for immediate internal fixation. There is no increased risk of infection when converting EF to ORIF in the treatment of complex distal radius fractures when conversion occurs early or if EF pin sites are overlapped by the definitive fixation. Using an IRB approved protocol, medical records over nine years were queried to identify patients with distal radius fractures that had undergone initial EF and were later converted to ORIF. Charts were reviewed for demographic data, injury characteristics, operative details, time to conversion from EF to ORIF, assessment of whether the EF pin sites overlapped the definitive fixation, presence of infection after ORIF, complications, and occupational therapy measurements of range of motion and strength. In total, 16 patients were identified, only one of which developed an infection following conversion to ORIF. Fisher's exact testing showed that infection did not depend on open fracture, time to conversion of one week or less, presence of EF pin sites overlapping definitive fixation, fracture classification, high energy mechanism of injury, or concomitant injury to the DRUJ. Planned staged conversion from EF to ORIF for complex distal radius fractures does not appear to result in an increased rate of infection if conversion occurs early or if the EF pin sites are overlapped by definitive fixation. This treatment paradigm may be reasonable for treating complex distal radius fractures in damage control situations, when there is extensive soft tissue injury, or when appropriate personnel/hospital resources are not available for immediate internal fixation. IV, retrospective case series. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Negative pressure wound therapy and external fixation device: a simple way to seal the dressing.

    PubMed

    Bulla, Antonio; Farace, Francesco; Uzel, André-Pierre; Casoli, Vincent

    2014-07-01

    Negative pressure therapy is widely applied to treat lower limb trauma. However, sealing a negative pressure dressing in the presence of an external fixation device may be difficult and time consuming. Therefore, screws, pins, wires, etc, may preclude the vacuum, preventing the plastic drape to perfectly adhere to the foam. To maintain the vacuum, we tried to prevent air leaking around the screws putting bone wax at the junction between the pins and the plastic drape. This solution, in our hands, avoids air leakage and helps maintain vacuum in a fast and inexpensive way.

  20. [Fat embolism syndrome following lower limb fracture despite rapid external fixation. Two case reports and review of the literature].

    PubMed

    Kleinert, K; Marug, D; Soklic, P; Simmen, H-P

    2009-09-01

    Fat embolism syndrome (FES) is a rare complication occurring in 0.9-2.2% of patients following long bone fractures. Patients present with a classical triad of respiratory manifestations, cerebral effects and petechiae. The incidence of FES is reduced by early immobilization of fractures and by minimally invasive operative management. Nevertheless, two healthy young men suffered from FES after immediate (within 3 h after trauma) external fixation of lower leg fractures. This postoperative complication should always be considered even after conservative or minimally invasive therapy.

  1. Gradual digital lengthening with autologous bone graft and external fixation for correction of flail toe in a patient with Raynaud's disease.

    PubMed

    Lamm, Bradley M; Ades, Joe K

    2009-01-01

    Iatrogenic flail toe is a complication of hammertoe surgery that occurs when an overaggressive resection of the proximal phalanx occurs. This can cause both functional and cosmetic concerns for the patient. We present a case report of the correction of a flail second toe in a patient with Raynaud's disease. The correction was achieved by means of gradual soft tissue lengthening with external fixation and an interposition autologous bone graft digital arthrodesis. After 5 months, this 2-stage procedure lengthened, stabilized, and restored the function of the toe. 4.

  2. All Internal Segmental Bone Transport and Optional Lengthening With a Newly Developed Universal Cylinder-Kombi-Tube Module for Motorized Nails-Description of a Surgical Technique.

    PubMed

    Krettek, Christian; El Naga, Ashraf

    2017-10-01

    Segmental transport is an effective method of treatment for segmental defects, but the need for external fixation during the transport phase is a disadvantage. To avoid external fixation, we have developed a Cylinder-Kombi-Tube Segmental Transport (CKTST) module for combination with a commercially available motorized lengthening nail. This CKTST module allows for an all-internal segmental bone transport and also allows for optional lengthening if needed. The concept and surgical technique of CKTST are described and illustrated with a clinical case.

  3. Correction of axial deformity during lengthening in fibular hypoplasia: Hexapodal versus monorail external fixation.

    PubMed

    Chalopin, A; Geffroy, L; Pesenti, S; Hamel, A; Launay, F

    2017-09-01

    Childhood fibular hypoplasia is a rare pathology which may or may not involve limb-length discrepancy and axial deformity in one or more dimensions. The objective of the present study was to compare the quality of the axial correction achieved in lengthening procedures by hexapodal versus monorail external fixators. The hypothesis was that the hexapodal fixator provides more precise correction. A retrospective multicenter study included 52 children with fibular hypoplasia. Seventy-two tibias were analyzed, in 2 groups: 52 using a hexapodal fixator, and 20 using a monorail fixator. Mean age was 10.2 years. Mean lengthening was 5.7cm. Deformities were analyzed and measured in 3 dimensions and classified in 4 preoperative types and 4 post-lengthening types according to residual deformity. Complete correction was achieved in 26 tibias in the hexapodal group (50%) and 2 tibias in the monorail group (10%). Mean post-correction mechanical axis deviation was smaller in the hexapodal group: 12.83mm, versus 14.29mm in the monorail group. Mean post-correction mechanical lateral distal femoral angle was 87.5° in the hexapodal group, versus 84.3° in the monorail group (P=0.002), and mean mechanical medial proximal tibial angle 86.9° versus 89.5°, respectively (P=0.015). No previous studies focused on this congenital pathology in lengthening and axial correction programs for childhood lower-limb deformity. The present study found the hexapodal fixator to be more effective in conserving or restoring mechanical axes during progressive bone lengthening for fibular hypoplasia. The hexapodal fixator met the requirements of limb-length equalization in childhood congenital lower-limb hypoplasia, providing better axial correction than the monorail fixator. IV. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. Improved vacuum sealing drainage for treatment of surgical site infection following posterior spinal internal fixation

    PubMed Central

    Zhang, Hengyan; Li, Qiyi

    2018-01-01

    Abstract Rationale: Surgical site infection (SSI) following spine surgeries involving internal fixation often require removing the instrument; however, this can cause spinal instability. Previous reports have demonstrated the usefulness of vacuum sealing drainage (VSD) therapy, but the cases require wound opening, aseptic condition to replace the VSD device, and a secondary operation to close the wound. Thus, to improve the VSD treatment and develop a maneuverable procedure, make sense in spine surgery. Patients concerns: A 59-year-old male patient with a T12 vertebral fracture was affected by SSIs after spinal osteotomy with internal fixation. Diagnoses: The patient complained of wound exudation and had a fever 3 weeks after posterior spinal surgery. Initial serum investigations showed elevated white blood cell count and bacterial cultures of wound exudate were positive for Enterococcus faecalis. Therefore, SSI is confirmed. Interventions: The infection was not controlled after 2 debridements, so the patient was treated with VSD treatment. The VSD foam dressings containing a drainage tube were placed into the wound from the exudation site of the wound until they contacted the internal fixation devices. After covering external fixation devices, continuous drainage was performed for 24 h. The VSD device was replaced every 4 to 5 days until the wound effusion stopped. All of the operations were performed at the bedside without complex manipulation or secondary closure under harsh aseptic condition. Outcomes: Wound exudation decreased remarkably and the infection was controlled 2 weeks after the application of VSD treatment. After 5 weeks, inflammatory indicators all decreased to normal levels and the exudate of the wound had stopped. The VSD treatment was then terminated and the drainage site of the wound was sutured. After 7 weeks, complete wound healing was achieved and no infection recurred during the 6-month follow-up. Lessons: VSD could be a reliable treatment for SSIs that require preservation of internal fixation. Complete opening of the wound during the VSD treatment and secondary wound closure surgery were avoided. PMID:29443786

  5. Increased wound complication with intramedullary screw fixation of clavicle fractures: Is it thermal necrosis?

    PubMed

    Domos, Peter; Tytherleigh-Strong, Graham; Van Rensburg, Lee

    2017-01-01

    Adult mid-shaft clavicle fractures are common injuries. For displaced fractures, open reduction with plate or intramedullary (IM) fixation is the widely used techniques. All methods have their own potential drawbacks, especially related to local soft tissue complications. There is little information about outcome and management of local wound complications after clavicle fracture fixations. Ninety-seven patients underwent open reduction and internal fixation, 17 were treated with IM screw fixation and 80 with plate fixation. Wound complication occurred in eight patients (8.2%) and rates differed significantly between IM and plate fixations (29.4% vs. 3.8%). Patients were assessed on average 58.3 months with visual analogue pain scores (VASs), Oxford Shoulder Score (OSS), and QuickDash (QD) score. Five patients had wound breakdown and three patients had wound erythema. In seven patients with stable fixation, it was possible to "dress and suppress" with average 3 weeks of oral antibiotics. One patient had unstable fixation and required longer antibiotic treatment with early screw removal. One patient developed a chronic discharging wound, requiring debridement and later plate removal. At final follow-up, all wounds remained healed, bony union was achieved in all. The average scores were: VAS 1, OSS 46, and QD 4.5. Good function with dry healed wound and united clavicle can be achieved. Further studies are required to investigate the difference in soft tissue complication rates, which may be due to the IM technique of retrograde drilling with a guide wire and due to aseptic thermal bone necrosis, rather than true infection.

  6. Early prophylactic autogenous bone grafting in type III open tibial fractures.

    PubMed

    Kesemenli, Cumhur C; Kapukaya, Ahmet; Subaşi, Mehmet; Arslan, Huseyin; Necmioğlu, Serdar; Kayikçi, Cuma

    2004-08-01

    The authors report the results achieved in patients with type III open tibial fractures who underwent primary autogenous bone grafting at the time of debridement and skeletal stabilisation. Twenty patients with a mean age of 35.8 years (range, 24-55) were treated between 1996 and 1999. Eight fractures were type IIIA, 11 were type IIIB, and 1 was type IIIC. At the index procedure, wound debridement, external fixation and autogenous bone grafting with bone coverage were achieved. The mean follow-up period was 46 months (range, 34-55). The mean time to fixator removal was 21 weeks (range, 14-35), and the mean time to union was 28 weeks (range, 19-45). Skin coverage was achieved by a myocutaneous flap in 2 patients, late primary closure in 4, and split skin grafting in 14. One (5%) of the patients experienced delayed union, and 1 (5%) developed infection. In tibial type III open fractures, skin coverage may be delayed, using the surrounding soft tissue to cover any exposed bone after thorough débridement and wound cleansing. Primary prophylactic bone grafting performed at the same time reduces the rate of delayed union, shortens the time to union, and does not increase the infection rate.

  7. Limb lengthening in Turner syndrome.

    PubMed Central

    Noonan, K. J.; Leyes, M.; Forriol, F.

    1997-01-01

    We report the results and complications of eight consecutive patients who underwent bilateral tibial lengthenings for dwarfism associated with Turner syndrome. Lengthening was performed via distraction osteogenesis with monolateral external fixation. Tibias were lengthened an average distance of 9.2 centimeters or 33 percent of the original tibial length. The average total treatment time was 268 days. The overall complication rate was 169 percent for each tibia lengthened and each segment required an average of 1.7 additional procedures. Seven cases (44 percent) required Achilles tendon lengthening and nine cases (56 percent) developed angulation before or after fixator removal; six of these segments required corrective osteotomy for axial malalignment. Two cases (12.5 percent) developed distraction site nonunion and required plating and bone grafting. From this series we conclude that tibial lengthening via distraction osteogenesis can be used to treat disproportionate short stature in patients with Turner syndrome. However, the benefit of a cosmetic increase in height may not compensate for the high complication rate. Efforts to determine the psychosocial and functional benefits of limb lengthening in patients with short stature is necessary to determine the true cost-benefit ratio of this procedure. Images Figure 1a Figure 1b Figure 1c PMID:9234980

  8. Management of civilian ballistic fractures.

    PubMed

    Seng, V S; Masquelet, A C

    2013-12-01

    The management of ballistic fractures, which are open fractures, has often been studied in wartime and has benefited from the principles of military surgery with debridement and lavage, and the use of external fixation for bone stabilization. In civilian practice, bone stabilization of these fractures is different and is not performed by external fixation. Fifteen civilian ballistic fractures, Gustilo II or IIIa, two associated with nerve damage and none with vascular damage, were reviewed. After debridement and lavage, ten internal fixations and five conservative treatments were used. No superficial or deep surgical site infection was noted. Fourteen of the 15 fractures (93%) healed without reoperation. Eleven of the 15 patients (73%) regained normal function. Ballistic fractures have a bad reputation due to their many complications, including infections. In civilian practice, the use of internal fixation is not responsible for excessive morbidity, provided debridement and lavage are performed. Civilian ballistic fractures, when they are caused by low-velocity firearms, differ from military ballistic fractures. Although the principle of surgical debridement and lavage remains the same, bone stabilization is different and is similar to conventional open fractures. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  9. Cosmetic arm lengthening with monorail fixator.

    PubMed

    Agrawal, Hemendra Kumar; Singh, Balvinder; Garg, Mohit; Khatkar, Vipin; Batra, Sumit; Sharma, Vinod Kumar

    2015-01-01

    Upper limb length discrepancy is a rare occurrence. Humerus shortening may need specialized treatment to restore the functional and cosmetic status of upper limb. We report a case of humerus lengthening of 9 cm with a monorail external fixator and the result was observed during a 2-year follow-up. Humerus lengthening needs specialized focus as it is not only a cosmetic issue but also a functional demand. The monorail unilateral fixator is more functional and cosmetically acceptable, and thus becomes an effective treatment option.

  10. Comparison of a modified mid-coronal sectioning technique and Wilson's technique when conducting eye and brain examinations in rabbit teratology studies.

    PubMed

    Ziejewski, Mary K; Solomon, Howard M; Rendemonti, Joyce; Stanislaus, Dinesh

    2015-02-01

    There are two methods used when examining fetal rabbit eyes and brain in teratology studies. One method employs prior fixation before serial sectioning (Wilson's technique) and the other uses fresh tissue (mid-coronal sectioning). We modified the mid-coronal sectioning technique to include removal of eyes and brain for closer examination and to increase the number of structures that can be evaluated and compared it to the Wilson's technique. We found that external examination of the head, in conjunction with either sectioning method, is equally sensitive in identifying developmental defects. We evaluated 40,401 New Zealand White (NZW) and Dutch-Belted (DB) rabbit fetuses for external head alterations, of which 28,538 fetuses were further examined for eye and brain alterations using the modified mid-coronal sectioning method (16,675 fetuses) or Wilson's technique (11,863 fetuses). The fetuses were from vehicle control or drug-treated pregnant rabbits in embryo-fetal development studies conducted to meet international regulatory requirements for the development of new drugs. Both methods detected the more common alterations (microphthalmia and dilated lateral cerebral ventricles) and other less common findings (changes in size and/or shape of eye and brain structures). While both methods are equally sensitive at detecting common and rare developmental defects, the modified mid-coronal sectioning technique eliminates the use of chemicals and concomitant fixation artifacts that occur with the Wilson's technique and allows for examination of 100% intact fetuses thereby increasing potential for detecting eye and brain alterations as these findings occur infrequently in rabbits. © 2015 Wiley Periodicals, Inc.

  11. Vibration Testing Procedures for Bone Stiffness Assessment in Fractures Treated with External Fixation.

    PubMed

    Mattei, Lorenza; Longo, Antonia; Di Puccio, Francesca; Ciulli, Enrico; Marchetti, Stefano

    2017-04-01

    A bone healing assessment is crucial for the successful treatment of fractures, particularly in terms of the timing of support devices. However, in clinical practice, this assessment is only made qualitatively through bone manipulation and X-rays, and hence cannot be repeated as often as might be required. The present study reconsiders the quantitative method of frequency response analysis for healing assessments, and specifically for fractures treated with an external fixator. The novelty consists in the fact that bone excitation and response are achieved through fixator pins, thus overcoming the problem of transmission through soft-tissues and their damping effect. The main objective was to develop and validate a test procedure in order to characterize the treated bone. More than 80 tests were performed on a tibia phantom alone, a phantom with pins, and a phantom with a complete fixator. Different excitation techniques and input-output combinations were compared. The results demonstrated the effectiveness of a procedure based on impact tests using a micro-hammer. Pins and fixator were demonstrated to influence the frequency response of the phantom by increasing the number of resonant frequencies. This procedure will be applied in future studies to monitor healing both in in vitro and in vivo conditions.

  12. The effect of HIV on early wound healing in open fractures treated with internal and external fixation.

    PubMed

    Aird, J; Noor, S; Lavy, C; Rollinson, P

    2011-05-01

    There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to internal or external fixation of open fractures in this population, as HIV is not a significant risk factor for acute wound/implant infection. However, subgroup analysis of grade I open fractures in patients with advanced HIV and a low CD4 count (< 350) showed an increased risk of infection; we suggest that grade I open fractures in patients with advanced HIV should be treated by early debridement followed by fixation at an appropriate time.

  13. Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications.

    PubMed

    Vidović, Dinko; Matejčić, Aljoša; Ivica, Mihovil; Jurišić, Darko; Elabjer, Esmat; Bakota, Bore

    2015-11-01

    Distal tibial or pilon fractures are usually the result of combined compressive and shear forces, and may result in instability of the metaphysis, with or without articular depression, and injury to the soft tissue. The complexity of injury, lack of muscle cover and poor vascularity make these fractures difficult to treat. Surgical treatment of distal tibial fractures includes several options: external fixation, IM nailing, ORIF and minimally-invasive plate osteosynthesis (MIPO). Management of distal tibial fractures with MIPO enables preservation of soft tissue and remaining blood supply. This is a report of a series of prospectively studied closed distal tibial and pilon fractures treated with MIPO. A total of 21 patients with closed distal tibial or pilon fractures were enrolled in the study between March 2008 and November 2013 and completed follow-up. Demographic characteristics, mechanism of injury, time required for union, ankle range of motion and complications were recorded. Fractures were classified according to the AO/OTA classification. Nineteen patients were initially managed with an ankle-spanning external fixator. When the status of the soft tissue had improved and swelling had subsided enough, a definitive internal fixation with MIPO was performed. Patients were invited for follow-up examinations at 3 and 6 weeks and then at intervals of 6 to 8 weeks until 12 months. Mean age of the patients was 40.1 years (range 19-67 years). Eighteen cases were the result of high-energy trauma and three were the result of low-energy trauma. According to the AO/OTA classification there were extraarticular and intraarticular fractures, but only simple articular patterns without depression or comminution. The average time for fracture union was 19.7 weeks (range 12-38 weeks). Mean range of motion was 10° of dorsiflexion (range 5-15°) and 28.3° of plantar flexion (range 20-35°). Three cases were metalwork-related complications. Two patients underwent plate removal at 24 weeks because of plate impingement. There was one case of wound breakdown at 11 weeks. One patient had fracture union with tibial recurvatum of approximately 10°, without functional impairment. Two patients had delayed union. MIPO is a reliable method of treatment for distal tibial fractures; it provides a high union rate and good functional outcome with minimal soft tissue complications. Skin impingement remains a common complication with MIPO, but this can be solved by timely plate removal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Syndesmotic fixation in supination-external rotation ankle fractures: a prospective randomized study.

    PubMed

    Kortekangas, Tero H J; Pakarinen, Harri J; Savola, Olli; Niinimäki, Jaakko; Lepojärvi, Sannamari; Ohtonen, Pasi; Flinkkilä, Tapio; Ristiniemi, Jukka

    2014-10-01

    This study compared mid-term functional and radiologic results of syndesmotic transfixation with no fixation in supination external rotation (SER) ankle fractures with intraoperatively confirmed syndesmosis disruption. Our hypothesis was that early-stage good functional results would remain and unfixed syndesmosis disruption in SER IV ankle fractures would not lead to an increased incidence of osteoarthritis. A prospective study of 140 operatively treated patients with Lauge-Hansen SER IV (Weber B) ankle fractures was performed. After bony fixation, the 7.5-Nm standardized external rotation stress test for both ankles was performed under fluoroscopy. A positive stress examination was defined as a difference of more than 2 mm side-to-side in the tibiotalar or tibiofibular clear spaces on mortise radiographs. The patients were randomized to either syndesmotic screw fixation (13 patients) or no syndesmotic fixation (11 patients). After a minimum of 4 years of follow-up (mean, 58 months), ankle function and pain (Olerud-Molander, a 100-mm visual analogue scale [VAS] for ankle function and pain) and quality of life (RAND-36) of all 24 patients were assessed. Ankle joint congruity and osteoarthritis were assessed using mortise and lateral projection plain weight-bearing radiographs and magnetic resonance imaging (MRI; 3T) scans. Improvement in Olerud-Molander score, VAS, and RAND-36 showed no significant difference between groups during the follow-up. In the syndesmotic transfixation group, improvements in all functional parameters and pain measurements were not significant, whereas in the group without syndesmotic fixation, the Olerud-Molander score improved from 84 to 93 (P = .007) and the pain (VAS) score improved from 11 to 4 (P = .038) from 1 year to last follow-up. X-ray or MRI imaging showed no difference between groups at the last follow-up visit. With the numbers available, no significant difference in functional outcome or radiologic findings could be detected between syndesmosis transfixation and no-fixation patients with SER IV ankle fracture after a minimum of 4 years of follow-up. Level II, prospective comparative study. © The Author(s) 2014.

  15. Biological approach to treatment of intra-articular proximal tibial fractures with double osteosynthesis.

    PubMed

    Singh, Saurabh; Patel, Pankaj R; Joshi, Anil Kumar; Naik, Rajnikant N; Nagaraj, Chethan; Kumar, Sudeep

    2009-02-01

    The treatment of intra-articular proximal tibial fractures is associated with complications, and much conflicting literature exists concerning the treatment of choice. In our study, an attempt has been made to develop an ideal and adequate treatment protocol for these intra-articular fractures. The principle of double osteosynthesis, i.e., lateral minimally invasive plate osteosynthesis (MIPO), was combined with a medial external fixator to treat 22 intra-articular proximal tibial fractures with soft tissue injury with a mean follow-up of 25 months. Superficial pin track infection was observed in one case, and no soft tissue breakdown was noted. Loss of articular reconstruction was reported in one case. Bridging callus was seen at 12 weeks (8 weeks-7 months). The principle of substitution or double osteosynthesis, i.e., lateral MIPO, was combined with a medial external fixator and proved to be a fairly good method of fixation in terms of results and complications.

  16. Safety evaluation of large external fixation clamps and frames in a magnetic resonance environment.

    PubMed

    Luechinger, Roger; Boesiger, Peter; Disegi, John A

    2007-07-01

    Large orthopedic external fixation clamps and related components were evaluated for force, torque, and heating response when subjected to the strong electromagnetic fields of magnetic-resonance (MR) imaging devices. Forces induced by a 3-Tesla (T) MR scanner were compiled for newly designed nonmagnetic clamps and older clamps that contained ferromagnetic components. Heating trials were performed in a 1.5 and in a 3 T MR scanner with two assembled external fixation frames. Forces of the newly designed clamps were more than a factor 2 lower as the gravitational force on the device whereas, magnetic forces on the older devices showed over 10 times the force induced by earth acceleration of gravity. No torque effects could be found for the newly designed clamps. Temperature measurements at the tips of Schanz screws in the 1.5 T MR scanner showed a rise of 0.7 degrees C for a pelvic frame and of 2.1 degrees C for a diamond knee bridge frame when normalized to a specific absorption rate (SAR) of 2 W/kg. The normalized temperature increases in the 3 T MR scanner were 0.9 degrees C for the pelvic frame and 1.1 degrees C for the knee bridge frame. Large external fixation frames assembled with the newly designed clamps (390 Series Clamps), carbon fiber reinforced rods, and implant quality 316L stainless steel Schanz screws met prevailing force and torque limits when tested in a 3-T field, and demonstrated temperature increase that met IEC-60601 guidelines for extremities. The influence of frame-induced eddy currents on the risk of peripheral nerve stimulation was not investigated. Copyright 2006 Wiley Periodicals, Inc.

  17. Percutaneous external fixator pins with bactericidal micron-thin sol-gel films for the prevention of pin tract infection.

    PubMed

    Qu, Haibo; Knabe, Christine; Radin, Shula; Garino, Jonathan; Ducheyne, Paul

    2015-09-01

    Risk of infection is considerable in open fractures, especially when fracture fixation devices are used to stabilize the fractured bones. Overall deep infection rates of 16.2% have been reported. The infection rate is even greater, up to 32.2%, with external fixation of femoral fractures. The use of percutaneous implants for certain clinical applications, such as percutaneous implants for external fracture fixation, still represents a challenge today. Currently, bone infections are very difficult to treat. Very potent antibiotics are needed, which creates the risk of irreversible damage to other organs, when the antibiotics are administered systemically. As such, controlled, local release is being pursued, but no such treatments are in clinical use. Herein, the use of bactericidal micron-thin sol-gel films on metallic fracture fixation pins is reported. The data demonstrates that triclosan (2,4,4'-trichloro-2'-hydroxydiphenylether), an antimicrobial agent, can be successfully incorporated into micron-thin sol-gel films deposited on percutaneous pins. The sol-gel films continuously release triclosan in vitro for durations exceeding 8 weeks (longest measured time point). The bactericidal effect of the micron-thin sol-gel films follows from both in vitro and in vivo studies. Inserting percutaneous pins in distal rabbit tibiae, there were no signs of infection around implants coated with a micron-thin sol-gel/triclosan film. Healing had progressed normally, bone tissue growth was normal and there was no epithelial downgrowth. This result was in contrast with the results in rabbits that received control, uncoated percutaneous pins, in which abundant signs of infection and epithelial downgrowth were observed. Thus, well-adherent, micron-thin sol-gel films laden with a bactericidal molecule successfully prevented pin tract infection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. A biomechanical evaluation to optimize the configuration of a hinged external fixator for the primary treatment of severely displaced intraarticular calcaneus fractures with soft tissue damage.

    PubMed

    Besch, Lutz; Schmidt, Ina; Mueller, Michael; Daniels-Wredenhagen, Mark; Hilgert, Ralf-Eric; Varoga, Deike; Seekamp, Andreas

    2008-01-01

    The purpose of this investigation was to develop an optimized hinged external fixator for the primary treatment of dislocated, intra-articular calcaneus fractures with associated soft tissue damage. To this end, a calcaneus model was made out of a polyurethane block, and a steel cylinder served as the ankle joint and was connected to a synthetic model of the tibia via a metal clamp. A saw cut served as the fracture in the model. A Steinmann nail and Schanz screw were placed in defined positions in the model and connected medially and laterally with longitudinal support rods. The fixator allowed a total of 20 degrees of plantar- and dorsiflexion, with rotation in the virtual axis of the upper ankle joint. Changes in the model fracture were measured during cyclical strain, and at different screw positions in the model tibia and calcaneus. Miniature force sensors located on the longitudinal support rods, and a plantar tension spring, were used to measure pressure and tension. Reproducible values were determined and, with the optimal configuration, shifting within the osteotomy was minimal. In the experimental configuration, optimal tibial screw placement was 70 mm proximal to the rotation axis of the upper ankle joint, and optimal placement of the Steinmann nail was in the posterior surface of the calcaneus. These findings indicated that the hinged fixator allows 20 degrees of ankle movement without alteration of the rotation axis, and suggest that this type of external fixator can be used in all types of calcaneal fracture regardless of the soft tissue damage. ACFAS Level of Clinical Evidence: 5c.

  19. A clinical evaluation of alternative fixation techniques for medial malleolus fractures.

    PubMed

    Barnes, Hayley; Cannada, Lisa K; Watson, J Tracy

    2014-09-01

    Medial malleolus fractures have traditionally been managed using partially threaded screws and/or Kirschner wire fixation. Using these conventional techniques, a non-union rate of as high as 20% has been reported. In addition too many patients complaining of prominent hardware as a source of pain post-fixation. This study was designed to assess the outcomes of medial malleolar fixation using a headless compression screw in terms of union rate, the need for hardware removal, and pain over the hardware site. Saint Louis University and Mercy Medical Center, Level 1 Trauma Centers, St. Louis, MO. After IRB approval, we used billing records to identify all patients with ankle fractures involving the medial malleolus. Medical records and radiographs were reviewed to identify patients with medial malleolar fractures treated with headless compression screw fixation. Our inclusion criteria included follow-up until full weight bearing and a healed fracture. Follow-up clinical records and radiographs were reviewed to determine union, complication rate and perception of pain over the site of medial malleolus fixation. Sixty-four ankles were fixed via headless compression screws and 44 had adequate follow-up for additional evaluation. Seven patients had isolated medial malleolar fractures, 23 patients had bimalleolar fractures, and 14 patients had trimalleolar fractures. One patient (2%) required hardware removal due to cellulitis. One patient (2%) had a delayed union, which healed without additional intervention. Ten patients (23%) reported mild discomfort to palpation over the medial malleolus. The median follow-up was 35 weeks (range: 12-208 weeks). There were no screw removals for painful hardware and no cases of non-union. Headless compression screws provide effective compression of medial malleolus fractures and result in good clinical outcomes. The headless compression screw is a beneficial alternative to the conventional methods of medial malleolus fixation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Clinical and radiological results on the fixation of Neer type 2 distal clavicle fractures with a hook plate.

    PubMed

    Şükür, Erhan; Öztürkmen, Yusuf; Akman, Yunus Emre; Güngör, Mustafa

    2016-10-01

    The aim of this study was to analyze the clinical and functional results of hook plate fixation in Neer type 2 distal clavicle fractures. We retrospectively analyzed 16 patients (11 males, 5 females) who were diagnosed with Neer type 2 distal clavicle fractures and treated with hook plate fixation between 2013 and 2014. Mean age was 38 (range: 27-61), and mean follow-up time was 14.3 (range: 12-18) months. Complications seen on radiographs were implant failure and subacromial osteolysis. The clinical results were evaluated with modified UCLA (University of California Los Angeles) scoring system. Bone union was achieved in all patients at the end of the first 4 months. Mean modified UCLA score was 32.75 (range 31-35). In 12 patients (68%), the implants had to be removed due to complications. After removal, the complaints regressed and shoulders' range of motion increased. Clinical and radiological results on the fixation of Neer type 2 distal clavicle fractures with a hook plate are good in terms of fracture union and function. The major disadvantage of the method was the requirement of early implant removal due to the hardware related complications and good results can be achieved only after plate removal. Optimizing the length of hook plate may lower the rate of complications. Level IV, Therapeutic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  1. Intraoperative assessment of the stability of the distal tibiofibular joint in supination-external rotation injuries of the ankle: sensitivity, specificity, and reliability of two clinical tests.

    PubMed

    Pakarinen, Harri; Flinkkilä, Tapio; Ohtonen, Pasi; Hyvönen, Pekka; Lakovaara, Martti; Leppilahti, Juhana; Ristiniemi, Jukka

    2011-11-16

    This study was designed to assess the sensitivity, specificity, and interobserver reliability of the hook test and the stress test for the intraoperative diagnosis of instability of the distal tibiofibular joint following fixation of ankle fractures resulting from supination-external rotation forces. We conducted a prospective study of 140 patients with an unstable unilateral ankle fracture resulting from a supination-external rotation mechanism (Lauge-Hansen SE). After internal fixation of the malleolar fracture, a hook test and an external rotation stress test under fluoroscopy were performed independently by the lead surgeon and assisting surgeon, followed by a standardized 7.5-Nm external rotation stress test of each ankle under fluoroscopy. A positive stress test result was defined as a side-to-side difference of >2 mm in the tibiotalar or the tibiofibular clear space on mortise radiographs. The sensitivity and specificity of each test were calculated with use of the standardized 7.5-Nm external rotation stress test as a reference. Twenty-four (17%) of the 140 patients had a positive standardized 7.5-Nm external rotation stress test after internal fixation of the malleolar fracture. The hook test had a sensitivity of 0.25 (95% confidence interval, 0.12 to 0.45) and a specificity of 0.98 (95% confidence interval, 0.94 to 1.0) for the detection of the same instabilities. The external rotation stress test had a sensitivity of 0.58 (95% confidence interval, 0.39 to 0.76) and a specificity of 0.96 (95% confidence interval, 0.90 to 0.98). Both tests had excellent interobserver reliability, with 99% agreement for the hook test and 98% for the stress test. Interobserver agreement for the hook test and the clinical stress test was excellent, but the sensitivity of these tests was insufficient to adequately detect instability of the syndesmosis intraoperatively.

  2. Photoactive TiO2 antibacterial coating on surgical external fixation pins for clinical application

    PubMed Central

    Villatte, Guillaume; Massard, Christophe; Descamps, Stéphane; Sibaud, Yves; Forestier, Christiane; Awitor, Komla-Oscar

    2015-01-01

    External fixation is a method of osteosynthesis currently used in traumatology and orthopedic surgery. Pin tract infection is a common problem in clinical practice. Infection occurs after bacterial colonization of the pin due to its contact with skin and the local environment. One way to prevent such local contamination is to create a specific coating that could be applied in the medical field. In this work, we developed a surface coating for external fixator pins based on the photocatalytic properties of titanium dioxide, producing a bactericidal effect with sufficient mechanical strength to be compatible with surgical use. The morphology and structure of the sol-gel coating layers were characterized using, respectively, scanning electron microscopy and X-ray diffraction. The resistance properties of the coating were investigated by mechanical testing. Photodegradation of acid orange 7 in aqueous solution was used as a probe to assess the photocatalytic activity of the titanium dioxide layers under ultraviolet irradiation. The bactericidal effect induced by the process was evaluated against two strains, ie, Staphylococcus aureus and multiresistant Staphylococcus epidermidis. The coated pins showed good mechanical strength and an efficient antibacterial effect after 1 hour of ultraviolet irradiation. PMID:26005347

  3. Combination of Open Subtotal Calcanectomy and Stabilization With External Fixation as Limb Salvage Procedure in Hindfoot-Infected Diabetic Foot Ulcers.

    PubMed

    Dalla Paola, Luca; Carone, Anna; Boscarino, Giulio; Scavone, Giuseppe; Vasilache, Lucian

    2016-12-01

    Diabetic hindfoot ulcers, complicated by osteomyelitis, are associated with a high risk of major amputation. Partial calcanectomy, preceded by an effective management of the infection and of the eventual peripheral artery disease, can be considered as valid therapeutic option. We have evaluated a therapeutic protocol for diabetic hindfoot ulcers complicated by osteomyelitis, which, besides an adequate surgical debridement, considers a reconstructive pathway assisted by the positioning of a circular external fixator. We made a prospective study of a cohort of diabetic patients affected by heel ulcer complicated by osteomyelitis. All patients underwent open partial calcanectomy associated with the positioning of a circular external frame specifically designed for hindfoot stabilization and offloading. A reconstructive procedure was implemented starting with the application of negative pressure wound therapy and coverage with dermal substitute and split thickness skin grafting. From November 2014 to November 2015, 18 consecutive patients were enrolled. Mean follow-up period was 212.3 ± 64.0 days. Healing was achieved in 18 (100%) patients. The mean healing time was 69.0 ± 64.0 days. No major amputation had to be performed during the follow-up. Open partial calcanectomy associated with external fixation and skin reconstruction was as efficient as limb salvage in patients with infected lesions of the hindfoot complicated by calcaneal osteomyelitis.

  4. Early sensitivity for eyes within faces: a new neuronal account of holistic and featural processing

    PubMed Central

    Nemrodov, Dan; Anderson, Thomas; Preston, Frank F.; Itier, Roxane J.

    2017-01-01

    Eyes are central to face processing however their role in early face encoding as reflected by the N170 ERP component is unclear. Using eye tracking to enforce fixation on specific facial features, we found that the N170 was larger for fixation on the eyes compared to fixation on the forehead, nasion, nose or mouth, which all yielded similar amplitudes. This eye sensitivity was seen in both upright and inverted faces and was lost in eyeless faces, demonstrating it was due to the presence of eyes at fovea. Upright eyeless faces elicited largest N170 at nose fixation. Importantly, the N170 face inversion effect (FIE) was strongly attenuated in eyeless faces when fixation was on the eyes but was less attenuated for nose fixation and was normal when fixation was on the mouth. These results suggest the impact of eye removal on the N170 FIE is a function of the angular distance between the fixated feature and the eye location. We propose the Lateral Inhibition, Face Template and Eye Detector based (LIFTED) model which accounts for all the present N170 results including the FIE and its interaction with eye removal. Although eyes elicit the largest N170 response, reflecting the activity of an eye detector, the processing of upright faces is holistic and entails an inhibitory mechanism from neurons coding parafoveal information onto neurons coding foveal information. The LIFTED model provides a neuronal account of holistic and featural processing involved in upright and inverted faces and offers precise predictions for further testing. PMID:24768932

  5. Comparison of screw fixation with elastic fixation methods in the treatment of syndesmosis injuries in ankle fractures.

    PubMed

    Seyhan, Mustafa; Donmez, Ferdi; Mahirogullari, Mahir; Cakmak, Selami; Mutlu, Serhat; Guler, Olcay

    2015-07-01

    17 patients with ankle syndesmosic injury were treated with a 4.5mm single cortical screw fixation (passage of screw 4 cortices) and 15 patients were treated with single-level elastic fixation material. All patients were evaluated according to the AOFAS ankle and posterior foot scale at the third, sixth and twelfth months after the fixation. The ankle range of movement was recorded together with the healthy side. The Student's t test was used for statistical comparisons. No statistical significant difference was observed between the AOFAS scores (p>0.05). The range of dorsiflexion and plantar flexion motion of the elastic fixation group at the 6th and 12th months were significantly better compared to the screw fixation group (p<0.01). Elastic fixation is as functional as screw fixation in the treatment of ankle syndesmosis injuries. The unnecessary need of a second surgical intervention for removal of the fixation material is another advantageous aspect of this method of fixation. Copyright © 2015. Published by Elsevier Ltd.

  6. Glycogen in the Nervous System. I; Methods for Light and Electron Microscopy

    NASA Technical Reports Server (NTRS)

    Estable, Rosita F. De; Estable-Puig, J. F.; Miquel, J.

    1964-01-01

    'l'he relative value of different methods for combined light and electron microscopical studies of glycogen in the nervous tissue was investigated. Picroalcoholic fixatives preserve glycogen in a considerable amount but give an inadequate morphological image of glycogen distribution and are unsuitable for ultrastructural studies. Fixation by perfusion, with Dalton's chromeosmic fluid seems adequate for ultrastructural cytochemistry of glycogen. Furthermore it permits routine paraffin embedding of brain slices adjacent to those used for electron microscopy. Dimedone blocking is a necessary step for a selective staining of glycogen with PAS after osmic fixation. Enzymatic removal of glycogen in osmic fixed nervous tissue can be done In paraffin-embedded tissue. It can also be performed in glycolmethacrylate-embedded tissue without removal of the embedding medium. Paraphenylenediamine stains glycogen following periodic acid oxidation.

  7. Incidence of infection after early intramedullary nailing of open tibial shaft fractures stabilized with pinless external fixators

    PubMed Central

    Kulshrestha, Vikas

    2008-01-01

    Background: A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This disadvantage is overcome by the AO pinless fixator, in which the trocar points are clamped onto the outer cortex without penetrating it. This study was designed to evaluate the role of AO pinless fixators in primary stabilization of open diaphyseal tibial fractures that received staged treatment because of delayed presentation or poor general condition. We also analyzed the rate of infection on early conversion to intramedullary nail. Materials and Methods: This study is a retrospective review of 30 open diaphyseal fractures of tibia, which were managed with primary stabilization with pinless fixator and early exchange nailing. Outcome was evaluated in terms of fracture union and rate of residual infection. The data were compared with that available in the literature. Results: All the cases were followed up for a period of 2 years. The study includes Gustilo type 1 (n=10), 14 Gustilo type 2 (n=14), and type3 (n=6) cases. 6 cases (20%) had clamp site infection, 2 cases (6.7%) had deep infection, and in 28 cases (93%) the fracture healed and consolidated well. Conclusion: This study has highlighted the valuable role of pinless external fixator in the management of open tibial fractures in terms of safety and ease of application as well as the advantage of early conversion to intramedullary implant without the risk of deep infection. PMID:19753227

  8. Operative fixation of chest wall fractures: an underused procedure?

    PubMed

    Richardson, J David; Franklin, Glen A; Heffley, Susan; Seligson, David

    2007-06-01

    Chest wall fractures, including injuries to the ribs and sternum, usually heal spontaneously without specific treatment. However, a small subset of patients have fractures that produce overlying bone fragments that may produce severe pain, respiratory compromise, and, if untreated mechanically, result in nonunion. We performed open reduction and internal fixation on seven patients with multiple rib fractures-five in the initial hospitalization and two delayed--as well as 35 sternal fractures (19 immediate fixation and 16 delayed). Operative fixation was accomplished using titanium plates and screws in both groups of patients. All patients with rib fractures did well; there were no major complications or infections, and no plates required removal. Clinical results were excellent. There was one death in the sternal fracture group in a patient who was ventilator-dependent preoperatively and extubated himself in the early postoperative period. Otherwise, the results were excellent, with no complications occurring in this group. Three patients had their plates removed after boney union was achieved. No evidence of infection or nonunion occurred. The excellent results achieved in the subset of patients with severe chest wall deformities treated initially at our institution and those referred from outside suggest that operative fixation is a useful modality that is likely underused.

  9. Absent pedicles in campomelic dysplasia.

    PubMed

    McDowell, Michael M; Dede, Ozgur; Bosch, Patrick; Tyler-Kabara, Elizabeth C

    2017-06-01

    The objective of the present study is to report a case of campomelic dysplasia illustrating the absence of cervical and thoracic pedicles. This report reiterates the importance of this clinical peculiarity in the setting of spine instrumentation. A 10-year-old female patient with campomelic dysplasia presented with progressive kyphoscoliosis and signs of neural compromise. Imaging studies confirmed thoracic level stenosis and demonstrated absence of multiple pedicles in cervical and thoracic spine. The patient underwent decompression and instrumentation/fusion for her spinal deformity. The patient was instrumented between C2 and L4 with pedicle screws and sublaminar cables. However, pedicle fixation was not possible for the lower cervical and upper-mid thoracic spine. Also, floating posterior elements precluded the use of laminar fixation in the lower cervical spine. Cervicothoracic lumbosacral orthosis (CTLSO) was used for external immobilization to supplement the tenuous fixation in the cervicothoracic area. The patient improved neurologically with no signs of implant failure at the 2-year follow-up. Absence of pedicles and floating posterior elements present a challenge during spine surgery in campomelic dysplasia. Surgeons should prepare for alternative fixation methods and external immobilization when planning on spinal instrumentation in affected patients. Level IV Case Report.

  10. Comparison of two-staged ORIF and limited internal fixation with external fixator for closed tibial plafond fractures.

    PubMed

    Wang, Cheng; Li, Ying; Huang, Lei; Wang, Manyi

    2010-10-01

    To compare the results of two-staged open reduction and internal fixation (ORIF) and limited internal fixation with external fixator (LIFEF) for closed tibial plafond fractures. From January 2005 to June 2007, 56 patients with closed type B3 or C Pilon fractures were randomly allocated into groups I and II. Two-staged ORIF was performed in group I and LIFEF in group II. The outcome measures included bone union, nonunion, malunion, pin-tract infection, wound infection, osteomyelitis, ankle joint function, etc. These postoperative data were analyzed with Statistical Package for Social Sciences (SPSS) 13.0. Incidence of superficial soft tissue infection (involved in wound infection or pin-tract infection) in group I was lower than that in group II (P < 0.05), with significant difference. Group I has significantly less radiation exposure (P < 0.001). Group II had higher rates of malunion, delayed union, and arthritis symptoms, with no statistical significance. Both groups resulted similar ankle joint function. Logistic regression analysis indicated that smoking and fracture pattern were the two factors significantly influencing the final outcomes. In the treatment of closed tibial plafond fractures, both two-staged ORIF and LIFEF offer similar results. Patients undergo LIFEF carry significantly greater radiation exposure and higher superficial soft tissue infection rate (usually occurs on pin tract and does not affect the final outcomes).

  11. Treatment of Medial Malleolus or Pure Deltoid Ligament Injury in Patients with Supination-External Rotation Type IV Ankle Fractures.

    PubMed

    Wang, Xu; Zhang, Chao; Yin, Jian-Wen; Wang, Chen; Huang, Jia-Zhang; Ma, Xin; Wang, Cheng-Wei; Wang, Xue

    2017-02-01

    To investigate the effect of internal fixation on postoperative ankle function in patients with supination-external rotation type IV ankle fractures, including medial malleolus fractures and deltoid ligament injury. Between January 2012 and June 2014, patients with medial structure injuries were enrolled in this study and assigned to the medial malleolus fracture group or the deltoid ligament group. The surgical procedures for the two groups were documented. The follow-up endpoint was the time point when the steel plate or screw was removed from the lateral ankle. The Olerud-Molander ankle scoring system was used to assess ankle function. A total of 84 patients with supination-external rotation type IV ankle fractures had complete medical records and were included in this study. The average age of the patients was 44.16 years (range, 15-75). The patient sample included 39 males and 45 females. Overall, 49 patients (19 males and 30 females) suffered a medial malleolus fracture. The average age of these patients was 40.20 years (range, 15-75). Patients with a posterior malleolar fracture fragment >25% of the articular surface accounted for 81.6% (40 patients) of these patients. Overall, 35 patients (20 males and 15 females) experienced a deltoid ligament injury. The average age of these patients was 44.21 years (range, 17-73). Patients with a posterior malleolar fracture fragment >25% of the articular surface accounted for 11.5% (four patients) of these patients. Open reduction was performed in patients with medial malleolus fractures, and two 4.0-mm cannulated screws were used to fixate the posterior malleolus and the medial malleolus. The suture-anchor technique was used to repair the ligaments in patients with deltoid ligament injuries. The follow-up endpoint was the time point when the steel plate and screws were removed from the lateral ankle in patients. The average follow-up period was 13.4 months (range, 11-17). The Olerud-Molander ankle scoring system was used to assess postoperative ankle function. The average score for the patients in the medial malleolus fracture group was 90.3 points (range, 85-95). The average score for the patients in the deltoid ligament injury group was 87.7 points (range, 80-95). No significant differences were found in the scores between the two groups. Medial malleolus fracture and deltoid ligament injury are two different presentations of supination-external rotation type IV ankle fractures. Anatomic reduction of the articular surface concurrent with restoration of ankle stability can achieve favorable results for these two injuries. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  12. Transarticular fixation by hook plate versus coracoclavicular stabilization by single multistrand titanium cable for acute Rockwood grade-V acromioclavicular joint dislocation: a case-control study.

    PubMed

    Gao, You-Shui; Zhang, Yue-Lei; Ai, Zi-Sheng; Sun, Yu-Qiang; Zhang, Chang-Qing; Zhang, Wei

    2015-11-19

    Hook plate (HP) is popularly used for acute and severely displaced acromioclavicular (AC) dislocations. However, subacromial impingement and acromion osteolysis induced by transarticular fixation are notorious. The current case-control study was to compare transarticular fixation by HP to coracoclavicular (CC) stabilization by single multistrand titanium cable (MSTC). Between January 2006 and August 2009, 24 patients with acute AC dislocations were surgically treated by open reduction and transarticular fixation with HP. These patients were matched to a series of 24 patients, who were managed by CC stabilization with MSTC in the same period. All AC dislocations were graded as Rockwood type V. Implant was removed 8-12 months after the primary operation in all patients, and 12 months at least were needed to assess the maintenance of AC joint. Functional results were evaluated before implant removal as well as in the last follow-up based on Constant-Murley criteria. There were no differences of demographic data including age, dominant gender and side, injury-to-surgery interval, operation time and follow-up period. In terms of functionality, Constant score was 95.8 ± 4.1 in MSTC group, while 76.7 ± 8.0 in HP group before implant removal (P < 0.001). In detail, MSTC was superior to HP in pain, ROM and activities. Constant score was significantly improved to 86.1 ± 5.7 after hardware removal for patients in HP (P < 0.001). Degenerative change of acromioclavicular joint presented in 16 patients (66.7%) in patients treated by HP, while it was found in only 3 patients (12.5%) treated by MSTC (P < 0.001). MSTC is superior to HP for the treatment of Rockwood type-V acromioclavicular dislocation both before and after removal of the implant. Hardware removal is of great benefits for functional improvement in patients treated by HP.

  13. Correction of complex foot deformities using the Ilizarov external fixator.

    PubMed

    Kocaoğlu, Mehmet; Eralp, Levent; Atalar, Ata Can; Bilen, F Erkal

    2002-01-01

    There are many drawbacks to using conventional approaches to the treatment of complex foot deformities, like the increased risk of neurovascular injury, soft-tissue injury, and the shortening of the foot. An alternative approach that can eliminate these problems is the Ilizarov method. In the current study, a total of 23 deformed feet in 22 patients were treated using the Ilizarov method. The etiologic factors were burn contracture, poliomyelitis, neglected and relapsed clubfoot, trauma, gun shot injury, meningitis, and leg-length discrepancy (LLD). The average age of the patients was 18.2 (5-50) years. The mean duration of fixator application was 5.1 (2-14) months. We performed corrections without an osteotomy in nine feet and with an osteotomy in 14 feet. Additional bony corrective procedures included three tibial and one femoral osteotomies for lengthening and deformity correction, and one tibiotalar arthrodesis in five separate extremities. At the time of fixator removal, a plantigrade foot was achieved in 21 of the 23 feet by pressure mat analysis. Compared to preoperative status, gait was subjectively improved in all patients. Follow-up time from surgery averaged 25 months (13-38). Pin-tract problems were observed in all cases. Other complications were toe contractures in two feet, metatarsophalangeal subluxation from flexor tendon contractures in one foot, incomplete osteotomy in one foot, residual deformity in two feet, and recurrence of deformity in one foot. Our results indicate that the Ilizarov method is an effective alternative means of correcting complex foot deformities, especially in feet that previously have undergone surgery.

  14. Acromioclavicular joint reconstruction by coracoid process transfer augmented with hook plate.

    PubMed

    Wang, Yeming; Zhang, Jianguo

    2014-06-01

    Various techniques have been reported for the treatment of chronic acromioclavicular (AC) joint separation. The purpose of this study was to evaluate the results of surgical construction of coracoclavicular ligament using coracoid process transfer augmented with a hook plate fixation. Twenty-one patients treated with coracoid process transfer augmented with a hook plate fixation for chronic type III and V AC injuries were retrospectively analysed in 2003-2009. The age of the patients ranged from 23 to 58 years with an average age of 41.6 years. The patients were followed up clinically and radiographically, with an average of 33.0 months. Functional status and the ability to return to work were recorded during follow-up. Constant score and visual analogue scale (VAS) for pain were measured. The mean Constant score has increased from 70.9 points preoperatively to 90.7 points at follow-up. The mean VAS score has decreased from 4.7 preoperatively to 1.2 at follow-up. The average abduction was 172°, forward flexion was 170° and external rotation was 56°. There were 10 excellent results, 10 good results and one fair result. All patients had resumed their job or returned to original sport activity at mean 3.7 months postoperatively. No reduction loss was observed after plate removal and the final follow-up. Despite retrospective nature of the study, the outcomes of surgical construction with process transfer augmented with hook plate fixation are promising for chronic type III and V AC injuries. Therapeutic level IV. Retrospective case series, treatment study. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Implantable Subcutaneous Venous Access Devices: Is Port Fixation Necessary? A Review of 534 Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McNulty, Nancy J., E-mail: nancy.mcnulty@hitchcock.org; Perrich, Kiley D.; Silas, Anne M.

    2010-08-15

    Conventional surgical technique of subcutaneous venous port placement describes dissection of the port pocket to the pectoralis fascia and suture fixation of the port to the fascia to prevent inversion of the device within the pocket. This investigation addresses the necessity of that step. Between October 8, 2004 and October 19, 2007, 558 subcutaneous chest ports were placed at our institution; 24 cases were excluded from this study. We performed a retrospective review of the remaining 534 ports, which were placed using standard surgical technique with the exception that none were sutured into the pocket. Mean duration of port use,more » total number of port days, indications for removal, and complications were recorded and compared with the literature. Mean duration of port use was 341 days (182,235 total port days, range 1-1279). One port inversion/flip occurred, which resulted in malfunction and necessitated port revision (0.2%). Other complications necessitating port removal included infection 26 (5%), thrombosis n = 2 (<1%), catheter fracture/pinch n = 1 (<1%), pain n = 2 (<1%), and skin erosion n = 3 (1%). There were two arrhythmias at the time of placement; neither required port removal. The overall complication rate was 7%. The 0.2% incidence of port inversion we report is concordant with that previously published, although many previous reports do not specify if suture fixation of the port was performed. Suture fixation of the port, in our experience, is not routinely necessary and may negatively impact port removal.« less

  16. Prevention of arthrofibrosis after arthroscopic screw fixation of tibial spine fracture in children and adolescents.

    PubMed

    Parikh, Shital N; Myer, David; Eismann, Emily A

    2014-01-01

    Arthrofibrosis is a major complication of tibial spine fracture treatment in children, potentially resulting in knee pain, quadriceps weakness, altered gait, decreased function, inability to return to sports, and long-term osteoarthritis. Thus, prevention rather than treatment of arthrofibrosis is desirable. The purpose of this study was to evaluate an aggressive postoperative rehabilitation and early intervention approach to prevent permanent arthrofibrosis after tibial spine fracture treatment and to compare epiphyseal and transphyseal screws for fixation. A consecutive series of 24 patients younger than age 18 with displaced type II and III tibial spine fractures who underwent arthroscopic reduction and screw fixation between 2006 and 2011 were retrospectively reviewed. Final range of motion was compared between patients with epiphyseal (n=12) and transphyseal (n=9) screws. One-third (4 of 12) of patients with epiphyseal screws underwent arthroscopic debridement and screw removal approximately 3 months postoperatively; 3 patients lacked 5° to 15° of extension, 1 experienced pain with extension, and 1 had radiographic evidence of screw pullout, loss of reduction, and resultant malunion. In the transphyseal screw group, 3 patients had 10° loss of extension, and all corrected after arthroscopic debridement and screw removal. The two groups did not significantly differ in time to hardware removal or return to sports or final range of motion. No growth disturbances were identified in patients after transphyseal screw removal. An aggressive approach of postoperative rehabilitation and early intervention after arthroscopic reduction and screw fixation of tibial spine fractures in children was successful in preventing permanent arthrofibrosis.

  17. Proximal femoral resection and articulated hip distraction with an external fixator for the treatment of painful spastic hip dislocations in pediatric patients with spastic quadriplegia.

    PubMed

    Lampropulos, Mario; Puigdevall, Miguel H; Zapozko, Daniel; Malvárez, Héctor R

    2008-01-01

    We describe the results obtained with an alternative method of treatment for spastic painful hip dislocations in nonambulatory patients, which consists of a proximal femoral resection with capsular interposition arthroplasty, and the addition of a hinged external fixator for postoperative articulated hip distraction to allow for an immediate upright position and the ability to sit in a wheelchair. We performed this technique in three patients (four hips) with a mean age at the time of surgery of 15 years. Postoperatively, clinical improvement was observed in all four hips, with respect to pain relief, sitting tolerance, perineal care and functional range of motion.

  18. Management of maxillofacial injuries in Iraq.

    PubMed

    Kummoona, Raja

    2011-09-01

    These clinical studies reflect the experience of the author in managing 673 patients treated during the last 8 years. All patients were treated in the Maxillofacial Unit, Surgical Specialties Hospital, Medical City, Baghdad, and in the author's private clinic. Included patients were 530 males and 143 females; patients' age ranged between 1 year and 75 years (mean, 38 y). Distribution of injuries was as follows: fracture of the mandible, 287 (42.64%); middle third injuries, 39 (5.79%); orbital injuries, 236 (35.07%; including 12 cases with cranioorbital injuries); injuries in children, 27 (4.0%); fracture of the zygoma, 52 (7.73%); and fracture of the nose, 40 (5.94%).Maxillofacial injuries in this study were classified as follows: (1) craniomaxillofacial with head injuries and cerebrospinal fluid leak; (2) fracture of the middle third including Le Fort I, II, and III and midline split in the face; (3) fracture of the mandible as an isolated injury or as part of a facial skeleton injury; and (4) isolated complex injuries of the zygoma, the orbital skeleton, and the nasoethmoidal region.The technique used for treating middle third injuries was external fixation either by halo frame (with vertical rods and cheek wires) or by box frame (using 4 external pins connected by rods) or internal fixation by suspending the middle third with internal wires (0.5 mm stainless steel) from the zygomatic process of the frontal bone beneath the zygomatic arch down the lower arch bar. Fractures of the mandible were treated by gunning splint with intermaxillary fixation (IMF) or with open reduction and fixation by stainless steel wire with IMF or by IMF screw or by an arch bar and IMF. Other fractures such as fracture of the orbit were treated by bone graft, sialastic, or lyophilized dura with open reduction. Fractures of the zygoma were treated by open reduction and fixation with stainless steel wire and bone graft or by reduction without fixation. Fractures of the nose were treated by reduction with straightening of the septum with a splint (lead splint or polythene) or by external splint with plaster of Paris. With the techniques used, results from managing these cases were satisfactory.

  19. The Search for the Ideal Fixation of Palatal Fractures: Innovative Experience with a Mini-Locking Plate

    PubMed Central

    Pollock, Richard A.

    2008-01-01

    Fractures of the palate have defied conventional management, such that malrotation and disinclination of the palatal shelves occur in a significant number of patients after repair. The fractured palatal shelves of eight patients were first prealigned. To do so, one or more 205-mm ratchet clamps and two intermaxillary fixation (IMF) posts were used. Rigid fixation was then achieved by applying a 2.0-mm mini-locking titanium plate (across the palatal vault) and by applying an adaptation miniplate across the fracture line as it exited the anterior surface of the maxilla. Screws were passed directly through the mucoperiosteum, to engage the palatal shelves and to lock the locking plate into position. Lacerations in the mucoperiosteum were neither used to aid fixation nor used as portals for dissection; incisions and mucoperiosteal flaps in the palatal vault were avoided. Adjuncts, such as intraoral splints, have not been used in cases to date, and early mobilization was allowed. Reconstitution of the craniomaxillofacial buttresses was added in patients with more extensive maxillary injury. The palatal appliance and screws remained rigidly in position in the roof of the mouth, much like an external fixator, until their removal 8 to 12 weeks after the repair. No patient suffered erosion of the mucoperiosteum or other major morbidity, other than a transient fistula of the soft palate. The palatoalveolar segments remained in proper realignment and inclination, and pretraumatic occlusal patterns and the width and depth of the lower face appear to have been restored with one exception. The latter suffered a subtle posterolateral open bite that was corrected orthodontically. Prealignment of fractured palatal shelves with one or more large ratchet clamps and two IMF posts provides several points of forced reduction of the palatal shelves, along the dental arch. In addition, stabilization with mini-locking plate(s) in the palatal vault and an adaptation plate across the fracture line, as it exits the maxilla, appear to have merit, based on this preliminary report (n = 8). Outcomes seen on computed tomography and clinical examination during this 3-year experience have been favorable. PMID:22110785

  20. Minimally invasive treatment of pilon fractures with a low profile plate: preliminary results in 17 cases.

    PubMed

    Borens, Olivier; Kloen, Peter; Richmond, Jeffrey; Roederer, Goetz; Levine, David S; Helfet, David L

    2009-05-01

    To determine the results of "biologic fixation" with a minimally invasive plating technique using a newly designed low profile "Scallop" plate in the treatment of pilon fractures. Retrospective case series. A tertiary referral center. Seventeen patients were treated between 1999 and 2001 for a tibial plafond fracture at the Hospital for Special Surgery with a newly designed low-profile plate. Eleven of the fractures (65%) were high-energy injuries. Two fractures were open. Staged surgical treatment with open reduction and fixation of the fibular fracture and application of an external fixator was performed in 12 cases. As soon as the soft tissues and swelling allowed, i.e. skin wrinkling, the articular surface was reconstructed and simply reduced, if necessary through an small incision, and the articular block was fixed to the diaphysis using a medially placed, percutaneously introduced flat scallop plate. In the remaining five cases the operation was performed in one session. Time to healing and complications including delayed union, non-union, instrument failure, loss of fixation, infection, quality of reduction and number of reoperations were evaluated. Quality of results and outcome were graded using the ankle-hindfoot-scale and a modified rating system. All patients went on to bony union at an average time of 14 weeks. There were no plate failures or loss of fixation/reduction. Two superficial wound-healing problems resolved with local wound care. At an average follow up of 17 months (range 6-29 months) eight patients (47%) had an excellent result; seven (41%) had a fair result whereas two (12%) had a poor result. The average ankle-hindfoot-score was 86.1 (range 61-100). Four patients have had the hardware removed and one of them is awaiting an ankle arthrodesis. Based on these initial results, it appears that a minimally invasive surgical technique including new low profile plate can decrease soft tissue problems while leading to fracture healing and obtaining results comparable with other more recent series. We believe that this new "Scallop Plate" is effective for the treatment of pilon fractures and should be used in conjunction with a staged procedure in the acute trauma setting.

  1. A new method for selecting auricle positions in skull base reconstruction for temporal bone cancer.

    PubMed

    Tanaka, Kentaro; Yano, Tomoyuki; Homma, Tsutomu; Tsunoda, Atsunobu; Aoyagi, Masaru; Kishimoto, Seiji; Okazaki, Mutsumi

    2018-03-25

    In advanced temporal bone carcinoma cases, we attempted to preserve as much of the auricle as possible from a cosmetic and functional perspective. Difficulties are associated with selecting an adequate position for reconstructed auricles intraoperatively. We improved the surgical procedure to achieve a good postoperative auricle position. Nine patients were included in this study. All patients underwent subtotal removal of the temporal bone and resection of the external auditory canal while preserving most of the external ear, and lateral skull base reconstruction was performed with anterolateral thigh flaps. We invented a new device, the auricle localizer, to select the correct position for the replaced external ear. The head skin incision line and two points of three-point pin fixation were used as criteria, and a Kirschner wire was shaped as a basic line to match these criteria. Another Kirschner wire was shaped by wrapping it around the inferior edge of the external ear as the positioning line, and these two lines were then combined. To evaluate the postoperative auricle position, the auricle inclination angle was measured using head frontal cephalogram imaging. The external ear on the affected side clearly drooped postoperatively in nonlocalizer cases, whereas this was not obvious in localizer cases. Auricle inclination angles 1 year after surgery significantly differed between these two cases (P = 0.018). The surgical device, the auricle localizer, is useful for selecting intraoperative accurate auricle positions. The assessment index, the auricle inclination angle, is useful for quantitatively evaluating postoperative results. 4 Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Prevention of pin tract infection in external stainless steel fixator frames using electric current in a goat model.

    PubMed

    van der Borden, Arnout J; Maathuis, Patrick G M; Engels, Eefje; Rakhorst, Gerhard; van der Mei, Henny C; Busscher, Henk J; Sharma, Prashant Kumar

    2007-04-01

    Pin tract infections of external fixators used in orthopaedic reconstructive bone surgery are serious complications that can eventually lead to periostitis and osteomyelitis. In vitro experiments have demonstrated that bacteria adhering to stainless steel in a biofilm mode of growth detach under the influence of small electric currents, while remaining bacteria become less viable upon current application. Therefore, we have investigated whether a 100microA electric current can prevent signs of clinical infection around percutaneous pins, implanted in the tibia of goats. Three pins were inserted into the lateral right tibia of nine goats, of which one served for additional frame support. Two pins were infected with a Staphylococcus epidermidis strain of which one pin was subjected to electric current, while the other pin was used as control. Pin sites were examined daily. The wound electrical resistance decreased with worsening of the infection from a dry condition to a purulent stage. After 21 days, animals were sacrificed and the pins taken out. Infection developed in 89% of the control pin sites, whereas only 11% of the pin sites in the current group showed infection. These results show that infection of percutaneous pin sites of external fixators in reconstructive bone surgery can be prevented by the application of a small DC electric current.

  3. Enhanced bone screw fixation with biodegradable bone cement in osteoporotic bone model.

    PubMed

    Juvonen, Tiina; Koistinen, Arto; Kröger, Heikki; Lappalainen, Reijo

    2012-09-27

    The purpose of this study was to study the potential of novel biodegradable PCL bone cement to improve bone screw fixation strength in osteoporotic bone. The biomechanical properties of bone cement (ε-polycaprolactone, PCL) and fixation strength were studied using biomechanical tests and bone screws fixed in an osteoporotic bone model. Removal torques and pullout strengths were assessed for cortical, self-tapping, and cancellous screws inserted in the osteoporotic bone model (polyurethane foam blocks with polycarbonate plate) with and without PCL bone cement. Open cell and cellular rigid foam blocks with a density of 0.12 g/cm3 were used in this model. Removal torques were significantly (more than six-fold) improved with bone cement for cancellous screws. Furthermore, the bone cement improved pullout strengths three to 12 times over depending on the screw and model material. Biodegradable bone cement turned out to be a very potential material to stabilize screw fixation in osteoporotic bone. The results warrant further research before safe clinical use, especially to clarify clinically relevant factors using real osteoporotic bone under human body conditions and dynamic fatigue testing for long-term performance.

  4. [Application of polyguanidine solution for fixation of biological and anatomical specimens].

    PubMed

    Anichkov, N M; Danilova, I A; Riabinin, I A; Kipenko, A V

    2010-01-01

    A new method for fixation of biological material is described, and its effectiveness is compared to that one of formalin fixation. As an embalming agent, polyhexamethylenguanidine (PHMG) hydrochloride was used. Using the proposed method of fixation, the anatomical and histological preparations of human organs and of chick embryos at developmental 12 days, were produced. The anatomical preparations obtained show the appearance, similar to that of the recently removed organs. Histological preparations were free from significant distortions of the microscopic characteristics of the specimens, which are typical to the material fixed with formalin. The results of the study suggest the possibility of PHMG application in the morphological studies.

  5. Complications associated with operative fixation of acute midshaft clavicle fractures.

    PubMed

    Asadollahi, Saeed; Hau, Raphael C; Page, Richard S; Richardson, Martin; Edwards, Elton R

    2016-06-01

    The aim of this study was to review the complication rate and profile associated with surgical fixation of acute midshaft clavicle fracture in a large cohort of patients treated in a level I trauma centre. We identified all patients who underwent surgical treatment of acute midshaft clavicle fracture between 2002 and 2010. The study group consisted of 138 fractures (134 patients) and included 107 men (78%) and 31 women (22%); the median age of 35 years (interquartile range (IQR) 24-45). The most common mechanism of injury was a road traffic accident (78%). Sixty percent (n=83) had an injury severity score of ≥15 indicating major trauma. The most common fracture type (75%) was simple or wedge comminuted (2B1) according to the Edinburgh classification. The median interval between the injury and operation was 3 days (IQR 1-6). Plate fixation was performed in 110 fractures (80%) and intramedullary fixation was performed in 28 fractures (20%). There were 85 men and 25 women in the plate fixation group with median age of 35 years (IQR 25-45) There were 22 men and six women in the intramedullary fixation group with median age of 31 years (IQR 24-42 years). Statistical analysis was performed using independent sample t test, Mann Whitney test, and Chi square test. Significant P-value was <0.05. The overall incidence of complication was 14.5% (n=20). The overall nonunion rate was 6%. Postoperative wound infection occurred in 3.6% of cases. The incidence of complication associated with plate fixation was 10% (11 of 110 cases) compared to 32% associated with intramedullary fixation (nine of 28 cases; P=0.003). Thirty-five percent of complications were related to inadequate surgical technique and were potentially avoidable. Symptomatic hardware requiring removal occurred in 23% (n=31) of patients. Symptomatic metalware was more frequent after plate fixation compared to intramedullary fixation (26% vs 7%, P=0.03). Intramedullary fixation of midshaft clavicle fracture is associated with a higher incidence of complications. Plate fixation is associated with a higher rate of symptomatic metalware requiring removal compared to intramedullary fixation. Approximately one in three complications may be avoided by attention to adequate surgical technique. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. An alternative graft fixation technique for scaphoid nonunions treated with vascular bone grafting.

    PubMed

    Korompilias, Anastasios V; Lykissas, Marios G; Kostas-Agnantis, Ioannis P; Gkiatas, Ioannis; Beris, Alexandros E

    2014-07-01

    To present our experience with vascularized bone grafting based on the 1,2-intercompartmental supraretinacular artery for the management of established scaphoid nonunion and to investigate the efficacy of graft immobilization with a combination of Kirschner wires and transarticular external fixation. A retrospective chart and radiographic review was conducted for patients with the diagnosis of scaphoid nonunion of the proximal pole or the waist treated with the 1,2-intercompartmental supraretinacular artery-based vascularized graft and fixed with a combination of Kirschner wires and transarticular external fixation between 2007 and 2011. We observed 23 consecutive patients for a mean of 34 ± 4 months. All patients were males with mean age of 25 ± 5 years. All patients had scaphoid nonunion and associated humpback deformity. The mean duration of nonunion was 7 ± 1 months. All scaphoid nonunions united after the index procedure at a mean of 10 ± 1 weeks. Two patients had avascular necrosis of the proximal pole based on the preoperative magnetic resonance imaging findings. After surgery, deformity correction was achieved in all patients, as recorded by the decrease in the lateral intrascaphoid angle and the increase in the dorsal scaphoid angle. At the last follow-up, no patients reported wrist pain. The mean Disabilities of the Arm, Shoulder, and Hand score improved significantly from 32 ± 12 before the operation to 5 ± 3 at the last postoperative visit. All patients showed statistically significant improvement in the range of motion and the grip strength of the involved wrist. The results of this study support the combined use of Kirschner wires and transarticular external fixation for fixation of a 1,2-intercompartmental supraretinacular artery-based vascular bone graft in the treatment of scaphoid nonunions. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  7. Reverse Dynamization: Influence of Fixator Stiffness on the Mode and Efficiency of Large-Bone-Defect Healing at Different Doses of rhBMP-2.

    PubMed

    Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher

    2016-04-20

    Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  8. Improving tribological and anti-bacterial properties of titanium external fixation pins through surface ceramic conversion.

    PubMed

    Dong, Huan; Mukinay, Tatiana; Li, Maojun; Hood, Richard; Soo, Sein Leung; Cockshott, Simon; Sammons, Rachel; Li, Xiaoying

    2017-01-01

    In this study, an advanced ceramic conversion surface engineering technology has been applied for the first time to self-drilling Ti6Al4V external fixation pins to improve their performance in terms of biomechanical, bio-tribological and antibacterial properties. Systematic characterisation of the ceramic conversion treated Ti pins was carried out using Scanning electron microscope, X-ray diffraction, Glow-discharge optical emission spectroscopy, nano- and micro-indentation and scratching; the biomechanical and bio-tribological properties of the surface engineered Ti pins were evaluated by insertion into high density bone simulation material; and the antibacterial behaviour was assessed with Staphylococcus aureus NCTC 6571. The experimental results have demonstrated that the surfaces of Ti6Al4V external fixation pins were successfully converted into a TiO 2 rutile layer (~2 μm in thickness) supported by an oxygen hardened case (~15 μm in thickness) with very good bonding due to the in-situ conversion nature. The maximum insertion force and temperature were reduced from 192N and 31.2 °C when using the untreated pins to 182N and 26.1 °C when the ceramic conversion treated pins were tested. This is mainly due to the significantly increased hardness (more than three times) and the effectively enhanced wear resistance of the cutting edge of the self-drilling Ti pins following the ceramic conversion treatment. The antibacterial tests also revealed that there was a significantly reduced number of bacteria isolated from the ceramic conversion treated pins compared to the untreated pins of around 50 % after 20 h incubation, P < 0.01 (0.0024). The results reported are encouraging and could pave the way towards high-performance anti-bacterial titanium external fixation pins with reduced pin-track infection and pin loosing.

  9. The effect of laparotomy and external fixator stabilization on pelvic volume in an unstable pelvic injury.

    PubMed

    Ghanayem, A J; Wilber, J H; Lieberman, J M; Motta, A O

    1995-03-01

    Determine if laparotomy further destabilizes an unstable pelvic injury and increases pelvic volume, and if reduction and stabilization restores pelvic volume and prevents volume changes secondary to laparotomy. Cadaveric pelvic fracture model. Unilateral open-book pelvic ring injuries were created in five fresh cadaveric specimens by directly disrupting the pubic symphysis, left sacroliac joint, and sacrospinous and sacrotuberous ligaments. Pelvic volume was determined using computerized axial tomography for the intact pelvis, disrupted pelvis with both a laparotomy incision opened and closed, and disrupted pelvis stabilized and reduced using an external fixator with the laparotomy incision opened. The average volume increase in the entire pelvis (from the top of the iliac crests to the bottom of the ischial tuberosities) between a nonstabilized injury with the abdomen closed and then subsequently opened was 15 +/- 5% (423 cc). The average increase in entire pelvic volume between a stabilized and reduced pelvis and nonstabilized pelvis, both with the abdomen open, was 26 +/- 5% (692 cc). The public diastasis increased from 3.9 to 9.3 cm in a nonstabilized pelvis with the abdomen closed and then subsequently opened. Application of a single-pin anterior-frame external fixator reduced the pubic diastasis anatomically and reduced the average entire and true (from the pelvic brim to the ischeal tuberosities) pelvic volumes to within 3 +/- 4 and 8 +/- 6% of the initial volume, respectively. We believe that the abdominal wall provides stability to an unstable pelvic ring injury via a tension band effect on the iliac wings. Our results demonstrate that a laparotomy further destabilized an open-book pelvic injury and subsequently increased pelvic volume and pubic diastasis. This could potentially increase blood loss from the pelvic injury and delay the tamponade effect of reduction and stabilization. A single-pin external fixator prevents the destabilizing effect of the laparotomy and effectively reduces pelvic volume. These data support reduction and temporary stabilization of unstable pelvic injuries before or concomitantly with laparotomy.

  10. Endoscopic stent suture fixation for prevention of esophageal stent migration during prolonged dilatation for achalasia treatment.

    PubMed

    Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F

    2017-04-01

    The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Techniques of Celloidin Removal From Temporal Bone Sections

    PubMed Central

    O’Malley, Jennifer T.; Burgess, Barbara J.; Jones, Diane D.; Adams, Joe C.; Merchant, Saumil N.

    2009-01-01

    Objectives We sought to determine whether the technique of celloidin removal influences the results of immunostaining in celloidin-embedded cochleae. Methods We compared four protocols of celloidin removal, including those using clove oil, acetone, ether-alcohol, and methanol saturated with sodium hydroxide. By optimally fixing our tissue (perfused mice), and keeping constant the fixative type (formalin plus acetic acid), fixation time (25 hours), and decalcification time (ethylenediaminetetraacetic acid for 7 days), we determined whether the technique of celloidin removal influenced the immunostaining results. Six antibodies were used with each removal method: prostaglandin D synthase, sodium, potassium adenosine triphosphatase (Na+,K+-ATPase), aquaporin 1, connective tissue growth factor, tubulin, and 200 kd neurofilament. Results Clove oil, acetone, and ether-alcohol resulted in incomplete removal of the celloidin, thereby negatively affecting the results of immunostaining. The methanol–sodium hydroxide method was effective in completely removing the celloidin; it produced the cleanest and most reproducible immunostaining for all six antibodies. Conclusions Freshly prepared methanol saturated with sodium hydroxide and diluted 1:2 with methanol was the best solvent for removing celloidin from mouse temporal bone sections, resulting in consistent and reproducible immunostaining with the six antibodies tested. PMID:19663375

  12. Initial Experience of US Marine Corps Forward Resuscitative Surgical System during Operation Iraqi Freedom

    DTIC Science & Technology

    2005-01-01

    lavage, and splinting. Exter- nal fixation was used when there was concurrent vascular pro- cedures or if fractures were extremely unstable...foot open fracture Completion lower extremity amputation; completion right upper amputation; external fixation right ankle 8/Iraqi child Class 3 shock...infection Comminuted mandible fracture with loss of airway (casualty 1 in Table 2) Airway control Infection of mandibular plate at echelon 5 facility

  13. Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture

    PubMed Central

    Facaros, Zacharia; Ramanujam, Crystal L.; Stapleton, John J.

    2010-01-01

    The surgical management of ankle fractures among the diabetic population is associated with higher complication rates compared to the general population. Efforts toward development of better methods in prevention and treatment are continuously evolving for these injuries. The presence of peripheral neuropathy and the possible development of Charcot neuroarthropathy in this high risk patient population have stimulated much surgical interest to create more stable osseous constructs when open reduction of an ankle fracture/dislocation is required. The utilization of multiple syndesmotic screws (pro-syndesmotic screws) to further stabilize the ankle mortise has been reported by many foot and ankle surgeons. In addition, transarticular Steinmann pins have been described as an adjunct to traditional open reduction with internal fixation (ORIF) of the ankle to better stabilize the talus, thus minimizing risk of further displacement, malunion, and Charcot neuroarthropathy. The authors present a unique technique of ORIF with pro-syndesmotic screws and the application of a multi-plane circular external fixator for management of a neglected diabetic ankle fracture that prevented further deformity while allowing a weight-bearing status. This techniqu may be utilized for the management of complex diabetic ankle fractures that are prone to future complications and possible limb loss. PMID:22396812

  14. [Tibiotalocalcaneal arthrodesis using a retrograde nail locked in the sagittal plane].

    PubMed

    Veselý, R; Procházka, V; Visna, P; Valentová, J; Savolt, J

    2008-04-01

    To evaluate our experience with the use of a retrograde nail locked in the sagittal plane for tibiotalocalcaneal arthrodesis indicated in severe post-traumatic arthritis of the ankle. Twenty patients, 16 men and four women at an average age of 58.7 years (range, 23 to 72) were evaluated. All patients had severe post-traumatic changes in the talocrural and talocalcaneal joints. Five patients also had an equinus deformity. In two patients arthrodesis followed the treatment of purulent arthritis of the talocrural joint. A local fasciocutaneous flap was used for soft tissue reconstruction in three patients. All patients were operated on using the standard surgical technique. METHODS With the patient in a supine position, reamed by hand with the use of a driving rod, a straight retrograde AAN Orthofix nail was inserted through the heel bone and talus into the distal tibia and locked in these bones in the sagittal plane. No complications such as injury to the neurovascular plexus or pseudoarthrosis were recorded. Four patients showed a reaction to the proximal locking screw on the proximal tibial surface, which was treated by earlier screw removal under topical anaesthesia. Due to infectious complications, the nail had to be removed prematurely in one patient. The average Foot Function Index was 12 points (range, 10 to 15) and the average ankle-hindfoot score was 67.6 points (range, 59 to 84). Thirteen patients (65 %) were not limited in their daily activities or recreational sports, six (30 %) experienced pain in sports but not daily activities and one patient (5 %) reported pain even when walking. All fusions healed in the correct position within 18 weeks. Tibiotalocalcaneal arthrodesis is not a frequent surgical procedure in either trauma surgery or orthopaedics. For this complicated procedure, rather than intramedullary nails, internal fixation with screws or plates or external fixation are preferred. The high rate of bony healing can be explained by maintenance of exact nail locking in the sagittal plane. The antero- posterior approach provides a more secure locking in the bone and assists in neutralizing sagittal forces at the site of arthrodesis. The use of reamed interlocking nails can therefore be accepted not only for treatment of long-bone fractures, but also for treating pseudoarthrosis and in complicated or failed arthrodesis. Patients' satisfaction is the primary goal we strive to achieve in severe post-traumatic conditions of the talus and foot. Repeat surgery, spongioplasty, external fixation revision for pin-tract infection, persistent pain, activity restriction and poor clinical results reduce patients' satisfaction. In our group, the rate of healed arthrodesis was high and the number of complications was low, therefore our patients' satisfaction was high.

  15. Impact of bracket displacement or rotation during bonding and time of removal of excess adhesive on the bracket-enamel bond strength.

    PubMed

    Oliveira, Adauê S; Barwaldt, Caroline K; Bublitz, Luana S; Moraes, Rafael R

    2014-06-01

    This study investigated the the influence of bracket displacement or rotation during fixation and the time of excess adhesive removal from around the bracket on bond strength to enamel. Stainless steel brackets were bonded to the buccal faces of bovine incisors using Transbond XT® adhesive resin. The teeth were divided into five groups (n = 20). In the control group, no displacement or rotation of the bracket was carried out. In the Displac-A group, excess adhesive was removed after the bracket was displaced 2 mm incisally. In the B-Displac group, excess adhesive was removed before the bracket was displaced incisally. In the Rotat-A group, excess adhesive was removed after the bracket was rotated 45°. In the B-Rotat group, excess adhesive was removed before the bracket was rotated. Photoactivation was carried out on the lateral sides of the bracket. A shear test was conducted 10 min after fixation using a knife-edged chisel. Bond strength data were analysed using ANOVA and Fisher's test (5%). The adhesive remnant index (ARI) was scored under magnification. ARI data were analysed using the Kruskal-Wallis test (5%). No significant differences were detected among the Control, Displac-A, Rotat-A and B-Rotat groups. The B-Displac group showed lower bond strength than all of the other groups, except Displac-A. No significant differences were observed in ARI scores across groups. Displacements of the brackets during fixation did not seem to affect the enamel bond strength when excess adhesive is removed after the final positioning of the bracket. © 2014 British Orthodontic Society.

  16. Factors affecting the use of increment cores to assess fixation

    Treesearch

    Stan T. Lebow

    2001-01-01

    As part of an effort to ensure that treated wood products have minimal environmental and handling concerns, an American Wood Preservers Association task force is considering the development of a test to assess the degree of fixation of Waterborne wood preservatives. The proposed test involves removal and leaching of increment cores. This paper describes a laboratory...

  17. The efficiency of Amberjet 4200 resin in removing nitrate in the presence of competitive anions from Shiraz drinking water.

    PubMed

    Dehghani, M; Haghighi, A Binaee; Zamanian, Z

    2010-06-01

    The aim of this research is to study the feasibility of removing nitrates from water by means of anion exchange. In the purposed work an attempt was made to utilize strong basic anion resin to remove nitrate in the presence of competitive anion. Amberjet Cl- 4200 ion exchange resin was used in a batch scale. The fixation rate of nitrate without the presences of any competitive anion was almost constant (94.60-96.43) when the nitrate concentrations are in the range of 100-150 mg L(-1). The fixation rate of nitrate in the presences of two competitive anions (sulphate and chloride) was reduced to 82% when the concentration of nitrate was 100 mg L(-1).

  18. The structure and functioning of Dynastab DK - K fixator (knee joint) and its usefullness in clinical use.

    PubMed

    Deszczyński, J; Karpiński, J; Deszczyńska, H

    1999-12-30

    The autor describes following stages of research on external fixator Dynastab DK - K (knee joint) with in - built artificial joint enabling physiological range of movement of the knee and the use of the device in functional treatment of articular fractures of the knee. The final clinical prototype of the device was developed according to the results of the experiments with anatomical preparations of knee joints in which the trajectory of the physiological movement of the knee was stated. These observations were used to construct mechanical joint with the range of movement adequate to this of the healthy knee. The positive and negative aspects in DK - K fixator are also described. The fixator was appled in 6 difficult cases of articular fractures of knee with good results.

  19. SURGICAL OUTCOME OF SIMULTANEOUS INTRAOCULAR LENS RESCUE AND SUTURELESS INTRASCLERAL TUNNEL FIXATION OF DISLOCATED INTRAOCULAR LENSES.

    PubMed

    Kim, Min; Lee, Dong H; Koh, Hyoung J; Lee, Sung C; Kim, Sung S

    2015-07-01

    To report short-term surgical outcomes of single-stage simultaneous rescue and sutureless intrascleral fixation of dislocated intraocular lens (IOLs). Sixteen eyes of 16 patients who underwent simultaneous rescue and intrascleral fixation of dislocated 3-piece IOLs were retrospectively evaluated. Partial thickness limbal-based scleral flaps (2.0 × 2.0 mm) were created, and a 22-gauge round needle was used to create a sclerotomy at 1.5 mm from the limbus under the previously created scleral flap, and a 23-gauge trans pars plana vitrectomy was performed. Bimanual maneuvers using two 23-gauge end-grasping forceps under chandelier illumination and a wide-angle viewing system enabled 1 step rescue of IOLs from the posterior vitreous cavity with 1 hand and simultaneous haptic externalization through sclerotomy with the other hand. An externalized haptic was placed into the 3-mm intrascleral tunnel created using a bent 26-gauge needle. Fibrin glue was used to fixate haptics and close the scleral flaps. Intraocular lenses were successfully rescued and sclera-fixated through intrascleral tunnels in all 16 eyes (mean age, 56.56 ± 19.89 years). The mean preoperative logarithm of the minimum angle of resolution best-corrected visual acuity was 0.92 ± 0.68, and this significantly improved at 6 months to 0.289 ± 0.36 (P = 0.003). During the follow-up period (10.1 ± 3.21 months), no significant change of endothelial cell count or central foveal thickness was noted postoperatively (P = 0.203 and P = 0.979, respectively). There were no significant postoperative complications such as IOL dislocation, IOL decentration, retinal detachment, endophthalmitis, or postoperative hypotony. Simultaneous rescue and sutureless intrascleral haptic fixation of dislocated 3-piece IOLs using bimanual maneuvers is an effective, safe, and minimally invasive surgical method to rescue and fixate the dislocated IOL without further explant.

  20. Hook plate fixation for acute acromioclavicular dislocations without coracoclavicular ligament reconstruction: a functional outcome study in military personnel.

    PubMed

    Kumar, Narinder; Sharma, Vyom

    2015-08-01

    The aim of our study was to evaluate the shoulder function after clavicular hook plate fixation of acute acromioclavicular dislocations (Rockwood type III) in a population group consisting exclusively of high-demand military personnel. This prospective study was carried out at a tertiary care military orthopaedic centre during 2012-2013 using clavicular hook plate for management of acromioclavicular injuries without coracoclavicular ligament reconstruction in 33 patients. All patients underwent routine implant removal after 16 weeks. The functional outcome was assessed at 3, 6 and 12 months after hook plate removal and 2 years from the initial surgery using the Constant Murley and UCLA Scores. All the patients were male serving soldiers and had sustained acromioclavicular joint dislocation (Rockwood type III). Mean age of the patient group was 34.24 years (21-55 years). The mean follow-up period in this study was 23.5 months (20-26 months) after hook plate fixation and an average of 19.9 months (17-22 months) after hook plate removal. The average Constant Score at 3 months after hook plate removal was 60.3 as compared to 83.7 and 90.3 at 6 months and 1 year, respectively, and an average of 91.8 at the last follow-up that was approximately 2 years after initial surgery which was statistically significant (p value <0.05). The UCLA Score was an average of 15.27, 25.9 and 30.1 at 3, 6 months and 1 year, respectively, after removal of hook plate which improved further an average of 32.3 at the last follow-up, which was also statistically significant (p value <0.05). Clavicular hook plate fixation without coracoclavicular ligament reconstruction is a good option for acute acromioclavicular dislocations producing excellent medium-term functional results in high-demand soldiers.

  1. Which Surgical Treatment for Open Tibial Shaft Fractures Results in the Fewest Reoperations? A Network Meta-analysis.

    PubMed

    Foote, Clary J; Guyatt, Gordon H; Vignesh, K Nithin; Mundi, Raman; Chaudhry, Harman; Heels-Ansdell, Diane; Thabane, Lehana; Tornetta, Paul; Bhandari, Mohit

    2015-07-01

    Open tibial shaft fractures are one of the most devastating orthopaedic injuries. Surgical treatment options include reamed or unreamed nailing, plating, Ender nails, Ilizarov fixation, and external fixation. Using a network meta-analysis allows comparison and facilitates pooling of a diverse population of randomized trials across these approaches in ways that a traditional meta-analysis does not. Our aim was to perform a network meta-analysis using evidence from randomized trials on the relative effect of alternative approaches on the risk of unplanned reoperation after open fractures of the tibial diaphysis. Our secondary study endpoints included malunion, deep infection, and superficial infection. A network meta-analysis allows for simultaneous consideration of the relative effectiveness of multiple treatment alternatives. To do this on the subject of surgical treatments for open tibial fractures, we began with systematic searches of databases (including EMBASE and MEDLINE) and performed hand searches of orthopaedic journals, bibliographies, abstracts from orthopaedic conferences, and orthopaedic textbooks, for all relevant material published between 1980 and 2013. Two authors independently screened abstracts and manuscripts and extracted the data, three evaluated the risk of bias in individual studies, and two applied Grading of Recommendation Assessment, Development and Evaluation (GRADE) criteria to bodies of evidence. We included all randomized and quasirandomized trials comparing two (or more) surgical treatment options for open tibial shaft fractures in predominantly (ie, > 80%) adult patients. We calculated pooled estimates for all direct comparisons and conducted a network meta-analysis combining direct and indirect evidence for all 15 comparisons between six stabilization strategies. Fourteen trials published between 1989 and November 2011 met our inclusion criteria; the trials comprised a total of 1279 patients surgically treated for open tibial shaft fractures. Moderate confidence evidence showed that unreamed nailing may reduce the likelihood of reoperation compared with external fixation (network odds ratio [OR], 0.38; 95% CI, 0.23-0.62; p < 0.05), although not necessarily compared with reamed nailing (direct OR, 0.74; 95% CI, 0.45-1.24; p = 0.25). Only low- or very low-quality evidence informed the primary outcome for other treatment comparisons, such as those involving internal plate fixation, Ilizarov external fixation, and Ender nailing. Method ranking based on reoperation data showed that unreamed nailing had the highest probability of being the best treatment, followed by reamed nailing, external fixation, and plate fixation. CIs around pooled estimates of malunion and infection risk were very wide, and therefore no conclusive results could be made based on these data. Current evidence suggests that intramedullary nailing may be superior to other fixation strategies for open tibial shaft fractures. Use of unreamed nails over reamed nails also may be advantageous in the setting of open fractures, but this remains to be confirmed. Unfortunately, these conclusions are based on trials that have had high risk of bias and poor precision. Larger and higher-quality head-to-head randomized controlled trials are required to confirm these conclusions and better inform clinical decision-making. Level I, therapeutic study.

  2. Pelvic ring injuries: Surgical management and long-term outcomes

    PubMed Central

    Halawi, Mohamad J.

    2016-01-01

    Pelvic ring injuries present a therapeutic challenge to the orthopedic surgeon. Management is based on the patient's physiological status, fracture classification, and associated injuries. Surgical stabilization is indicated in unstable injury patterns and those that fail nonsurgical management. The optimal timing for definitive fixation is not clearly defined, but early stabilization is recommended. Surgical techniques include external fixation, open reduction and internal fixation, and minimally invasive percutaneous osteosynthesis. Special considerations are required for concomitant acetabular fractures, sacral fractures, and those occurring in skeletally immature patients. Long-term outcomes are limited by lack of pelvis-specific outcome measures and burden of associated injuries. PMID:26908968

  3. Reverse Dynamization

    PubMed Central

    Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher

    2016-01-01

    Background: Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Methods: Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. Results: In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. Conclusions: These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Clinical Relevance: Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. PMID:27098327

  4. Insulation Failure of the Linox Defibrillator Lead: A Case Report and Retrospective Review of a Single Center Experience.

    PubMed

    Howe, Andrew J; McKeag, Nicholas A; Wilson, Carol M; Ashfield, Kyle P; Roberts, Michael J

    2015-06-01

    Implantable cardioverter defibrillator (ICD) lead insulation failure and conductor externalization have been increasingly reported. The 7.8F silicon-insulated Linox SD and Linox S ICD leads (Biotronik, Berlin, Germany) were released in 2006 and 2007, respectively, with an estimated 85,000 implantations worldwide. A 39-year-old female suffered an out-of-hospital ventricular fibrillation (VF) arrest with successful resuscitation. An ICD was implanted utilizing a single coil active fixation Linox(Smart) S lead (Biotronik, Berlin, Germany). A device-triggered alert approximately 3 years after implantation confirmed nonphysiological high rate sensing leading to VF detection. A chest X-ray showed an abnormality of the ICD lead and fluoroscopic screening confirmed conductor externalization proximal to the defibrillator coil. In view of the combined electrical and fluoroscopic abnormalities, urgent lead extraction and replacement were performed. A review of Linox (Biotronik) and Vigila (Sorin Group, Milan, Italy) lead implantations within our center (n = 98) identified 3 additional patients presenting with premature lead failure, 2 associated with nonphysiological sensed events and one associated with a significant decrease in lead impedance. All leads were subsequently removed and replaced. This case provides a striking example of insulation failure affecting the Linox ICD lead and, we believe, is the first to demonstrate conductor externalization manifesting both electrical and fluoroscopic abnormalities. © 2015 Wiley Periodicals, Inc.

  5. [TREATMENT OF PRONATION EXTERNAL ROTATION ANKLE FRACTURE COMBINED WITH SEPARATION OF DISTAL TIBIOFIBULAR SYNDESMOSIS].

    PubMed

    Wu, Benwen; Ding, Zhenqi; Huang, Guofeng; Liu, Guojun; Cai, Zhemin; Ding, Luobin; Li, Xiang

    2016-09-08

    To evaluate the difference between using and not using syndesmotic screw to treat pronation external rotation (PER) ankle fracture combined with separation of distal tibiofibular syndesmosis. Between April 2011 and October 2014, 46 cases of PER ankle fracture combined with separation of distal tibiofibular syndesmosis were treated, and syndesmotic screw was used in 24 cases (fixation group) and syndesmotic screw was not used in 22 cases (non-fixation group). There was no significant difference in gender, age, weight, cause of injury, side, injury to operation time, and fracture type between 2 groups ( P >0.05). The time for full weight-bearing, fracture healing time, and complications were recorded after operation. Anteroposterior and lateral X-ray films were taken to measure the tibiofibular overlap (TBOL) and tibiofibular clear space (TBCS). Baird-Jackson score was used to evaluate functional recovery of the ankle. All incision healed by first intention without complications. The cases were followed up 13-18 months (mean, 15.2 months) in 2 groups. The time for full weight-bearing was 8-12 weeks (median, 11 weeks) in fixation group, which was significantly later than that in non-fixation group (range, 6-10 weeks; median, 8 weeks) ( Z =-5.049, P =0.000). X-ray examination showed reduction of separation of distal tibiofibular syndesmosis. All fractures healed. The fracture healing time was (13.83±1.37) weeks in fixation group, and was (13.91±1.31) weeks in non-fixation group, showing no significant difference ( t =-0.191, P =0.945). No separation of distal tibiofibular syndesmosis, delayed union, nonunion, loosening, or breakage of fixation devices was observed in 2 groups. There was no significant difference in TBOL, TBCS, Baird-Jackson score and the excellent and good rate between 2 groups ( P >0.05). If the medial, lateral, and posterior structures of the ankle could be repaired according to injury, no significant influence on functional outcome of ankle or radiologic findings could be detected whether syndesmotic fixation is given or not in treating PER ankle fracture (exclude Maisonneuve fracture) combined with separation of distal tibiofibular syndesmosis.

  6. The role of external features in face recognition with central vision loss: A pilot study

    PubMed Central

    Bernard, Jean-Baptiste; Chung, Susana T.L.

    2016-01-01

    Purpose We evaluated how the performance for recognizing familiar face images depends on the internal (eyebrows, eyes, nose, mouth) and external face features (chin, outline of face, hairline) in individuals with central vision loss. Methods In Experiment 1, we measured eye movements for four observers with central vision loss to determine whether they fixated more often on the internal or the external features of face images while attempting to recognize the images. We then measured the accuracy for recognizing face images that contained only the internal, only the external, or both internal and external features (Experiment 2), and for hybrid images where the internal and external features came from two different source images (Experiment 3), for five observers with central vision loss and four age-matched control observers. Results When recognizing familiar face images, approximately 40% of the fixations of observers with central vision loss were centered on the external features of faces. The recognition accuracy was higher for images containing only external features (66.8±3.3% correct) than for images containing only internal features (35.8±15.0%), a finding contradicting that of control observers. For hybrid face images, observers with central vision loss responded more accurately to the external features (50.4±17.8%) than to the internal features (9.3±4.9%), while control observers did not show the same bias toward responding to the external features. Conclusions Contrary to people with normal vision who rely more on the internal features of face images for recognizing familiar faces, individuals with central vision loss show a higher dependence on using external features of face images. PMID:26829260

  7. The Role of External Features in Face Recognition with Central Vision Loss.

    PubMed

    Bernard, Jean-Baptiste; Chung, Susana T L

    2016-05-01

    We evaluated how the performance of recognizing familiar face images depends on the internal (eyebrows, eyes, nose, mouth) and external face features (chin, outline of face, hairline) in individuals with central vision loss. In experiment 1, we measured eye movements for four observers with central vision loss to determine whether they fixated more often on the internal or the external features of face images while attempting to recognize the images. We then measured the accuracy for recognizing face images that contained only the internal, only the external, or both internal and external features (experiment 2) and for hybrid images where the internal and external features came from two different source images (experiment 3) for five observers with central vision loss and four age-matched control observers. When recognizing familiar face images, approximately 40% of the fixations of observers with central vision loss was centered on the external features of faces. The recognition accuracy was higher for images containing only external features (66.8 ± 3.3% correct) than for images containing only internal features (35.8 ± 15.0%), a finding contradicting that of control observers. For hybrid face images, observers with central vision loss responded more accurately to the external features (50.4 ± 17.8%) than to the internal features (9.3 ± 4.9%), whereas control observers did not show the same bias toward responding to the external features. Contrary to people with normal vision who rely more on the internal features of face images for recognizing familiar faces, individuals with central vision loss show a higher dependence on using external features of face images.

  8. Ascorbate-apatite composite and ascorbate-FGF-2-apatite composite layers formed on external fixation rods and their effects on cell activity in vitro.

    PubMed

    Wang, Xiupeng; Ito, Atsuo; Sogo, Yu; Li, Xia; Tsurushima, Hideo; Oyane, Ayako

    2009-09-01

    Ascorbate-apatite and ascorbate-fibroblast growth factor-2 (FGF-2)-apatite composite layers were successfully formed on anodically oxidized Ti rods clinically used for external fixation by a one-step procedure at 25 degrees C, using a metastable supersaturated calcium phosphate solution supplemented with l-ascorbic acid phosphate magnesium salt n-hydrate (AsMg) and FGF-2. The AsMg-apatite and AsMg-FGF-2-apatite composite layers were evaluated in vitro using fibroblastic NIH3T3 and osteoblastic MC3T3-E1 cells. The AsMg-FGF-2-apatite composite layer markedly enhanced the NIH3T3 cell proliferation and procollagen type capital I, Ukrainian gene expression. Without FGF-2, the AsMg-apatite composite layer whose ascorbate content was 3.64+/-1.27microgcm(-2) obviously enhanced osteoblastic proliferation and differentiation. However, the AsMg-FGF-2-apatite composite layers whose FGF-2 contents were from 0.15+/-0.03 to 0.31+/-0.04microgcm(-2) inhibited osteoblastic differentiation in vitro. Thus, the AsMg-FGF-2-apatite composite layer should be precipitated on the surface of external fixators attached to skin and soft tissue. On the other hand, the AsMg-apatite composite layer should be precipitated at the part attached to bone tissue.

  9. Influence of meditation on anti-correlated networks in the brain.

    PubMed

    Josipovic, Zoran; Dinstein, Ilan; Weber, Jochen; Heeger, David J

    2011-01-01

    Human experiences can be broadly divided into those that are external and related to interaction with the environment, and experiences that are internal and self-related. The cerebral cortex appears to be divided into two corresponding systems: an "extrinsic" system composed of brain areas that respond more to external stimuli and tasks and an "intrinsic" system composed of brain areas that respond less to external stimuli and tasks. These two broad brain systems seem to compete with each other, such that their activity levels over time is usually anti-correlated, even when subjects are "at rest" and not performing any task. This study used meditation as an experimental manipulation to test whether this competition (anti-correlation) can be modulated by cognitive strategy. Participants either fixated without meditation (fixation), or engaged in non-dual awareness (NDA) or focused attention (FA) meditations. We computed inter-area correlations ("functional connectivity") between pairs of brain regions within each system, and between the entire extrinsic and intrinsic systems. Anti-correlation between extrinsic vs. intrinsic systems was stronger during FA meditation and weaker during NDA meditation in comparison to fixation (without mediation). However, correlation between areas within each system did not change across conditions. These results suggest that the anti-correlation found between extrinsic and intrinsic systems is not an immutable property of brain organization and that practicing different forms of meditation can modulate this gross functional organization in profoundly different ways.

  10. Management of simple (types A and B) closed tibial shaft fractures using percutaneous lag-screw fixation and Ilizarov external fixation in adults.

    PubMed

    El-Sayed, Mohamed; Atef, Ashraf

    2012-10-01

    Although intramedullary fixation of closed simple (type A or B) diaphyseal tibial fractures in adults is well tolerated by patients, providing lower morbidity rates and better mobility, it is associated with some complications. This study evaluated the results of managing these fractures using percutaneous minimal internal fixation using one or more lag screws, and Ilizarov external fixation. This method was tested to evaluate its efficacy in immediate weight bearing, fracture healing and prevention of any post-immobilisation stiffness of the ankle and knee joints. This randomised blinded study was performed at a referral, academically supervised, level III trauma centre. Three hundred and twenty-four of the initial 351 patients completed this study and were followed up for a minimum of 12 (12-88) months. Patient ages ranged from 20 to 51 years, with a mean of 39 years. Ankle and knee movements and full weight bearing were encouraged immediately postoperatively. Solid union was assessed clinically and radiographically. Active and passive ankle and knee ranges of motion were measured and compared with the normal side using the Wilcoxon signed rank test for matched pairs. Subjective Olerud and Molander Ankle Score was used to detect any ankle joint symptoms at the final follow-up. No patient showed delayed or nonunion. All fractures healed within 95-129 days. Based on final clinical and radiographic outcomes, this technique proves to be adequate for managing simple diaphyseal tibial fractures. On the other hand, it is relatively expensive, technically demanding, necessitates exposure to radiation and patients are expected to be frame friendly.

  11. Medial malleolar fractures: a biomechanical study of fixation techniques.

    PubMed

    Fowler, T Ty; Pugh, Kevin J; Litsky, Alan S; Taylor, Benjamin C; French, Bruce G

    2011-08-08

    Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO group recommends tension-band fixation of small avulsion type fractures of the medial malleolus that are unacceptable for screw fixation. A well-documented complication of this technique is prominent symptomatic implants and secondary surgery for implant removal. Replacing stainless steel 18-gauge wire with FiberWire suture could theoretically decrease symptomatic implants. Therefore, a second goal was to biomechanically compare these 2 tension-band constructs. Using a tibial Sawbones model, 2 bicortical screws were compared with 2 unicortical cancellous screws on a servohydraulic test frame in offset axial, transverse, and tension loading. Second, tension-band fixation using stainless steel wire was compared with FiberWire under tensile loads. Bicortical screw fixation was statistically the stiffest construct under tension loading conditions compared to unicortical screw fixation and tension-band techniques with FiberWire or stainless steel wire. In fact, unicortical screw fixation had only 10% of the stiffness as demonstrated in the bicortical technique. In a direct comparison, tension-band fixation using stainless steel wire was statistically stiffer than the FiberWire construct. Copyright 2011, SLACK Incorporated.

  12. Longitudinal bracketed epiphysis of proximal phalanx of the great toe with congenital hallux varus managed simultaneously with monorail external fixator: a case report.

    PubMed

    Verma, Vineet; Batra, Amit; Singla, Rohit; Gogna, Paritosh; Magu, Narender; Gupta, Rakesh

    2014-02-01

    Longitudinal bracketed epiphysis (delta phalanx) is a rare congenital anomaly that affects phalanges in the hand more commonly than toes. We present a rare case of congenital hallux varus with longitudinal bracketed epiphysis of proximal phalanx with bifid distal phalanx of the great toe, which was managed with monorail type of external fixator. To the best of our knowledge, this is the first report of its successful implementation in simultaneous treatment of longitudinal bracketed epiphysis of the proximal phalanx of the great toe and hallux varus. Apart from adding to the literature a case of rare subtype of delta phalanx with hallux varus, the present study highlights the role of a reliable alternative in its management.

  13. Pediatric distal femur fixation by proximal humeral plate.

    PubMed

    Abdelgawad, Amr Atef; Kanlic, Enes M

    2013-12-01

    Distal femoral metaphyseal fractures are common injuries in children. Multiple treatment options have been described for this type of injury. For older children with distal metaphyseal fracture, there is still no optimal method of fixation. We propose that the commonly used proximal humeral plate can provide good method of fixation for this fracture in adolescents. Two children (12 and 14 years old) with distal metaphyseal femoral fracture were treated with proximal humeral plate. We describe the surgical technique and postoperative management. The two children healed with good alignment and full range of motion of the knee. No external immobilization (other than knee immobilizer for the first 2 weeks) was used. We concluded that proximal humeral plate can provide adequate fixation for teenagers with distal femoral metaphyseal fracture. It is readily available; provide multiple options for screw fixation in the distal part of the fracture and fits easily on the distal part of the femur proximal to the physis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Reduction and temporary stabilization of Tile C pelvic ring injuries using a posteriorly based external fixation system.

    PubMed

    Martin, Murphy P; Rojas, David; Mauffrey, Cyril

    2018-07-01

    Tile C pelvic ring injuries are challenging to manage even in the most experienced hands. The majority of such injuries can be managed using percutaneous reduction techniques, and the posterior ring can be stabilized using percutaneous transiliac-transsacral screw fixation. However, a subgroup of patients present with inadequate bony corridors, significant sacral zone 2 comminution or significant lateral/vertical displacement of the hemipelvis through a complete sacral fracture. Percutaneous strategies in such circumstances can be dangerous. Those patients may benefit from prone positioning and open reduction of the sacral fracture with fixation through tension band plating or lumbo-pelvic fixation. Soft tissue handling is critical, and direct reduction techniques around the sacrum can be difficult due to the complex anatomy and the fragile nature of the sacrum making clamp placement and tightening a challenge. In this paper, we propose a mini-invasive technique of indirect reduction and temporary stabilization, which is soft tissue friendly and permits maintenance of reduction during definitive fixation surgical.

  15. Joint Distraction Treatments of Intra-Articular Fracture-Induced Posttraumatic Osteoarthritis in a Large Animal Model

    DTIC Science & Technology

    2017-10-01

    that was developed this Year for use in the upcoming Aim 2 studies. 15. SUBJECT TERMS External Fixator, Fracture Fixation Delay, Yucatan Minipig 16... Yucatan minipig model of PTOA after IAF that was developed during our previous work (W81XWH-10-1-0864) to investigate the use of joint distraction to...proactive treatment for PTOA. 2. KEYWORDS Post-traumatic Osteoarthritis Intra-articular Fracture Yucatan Miniature Pig Impact Ankle Cartilage

  16. External fixation for displaced intra-articular fractures of the calcaneum.

    PubMed

    Magnan, B; Bortolazzi, R; Marangon, A; Marino, M; Dall'Oca, C; Bartolozzi, P

    2006-11-01

    A minimally-invasive procedure using percutaneous reduction and external fixation can be carried out for Sanders' type II, III and IV fractures of the os calcis. We have treated 54 consecutive closed displaced fractures of the calcaneum involving the articular surface in 52 patients with the Orthofix Calcaneal Mini-Fixator. Patients were followed up for a mean of 49 months (27 to 94) and assessed clinically with the Maryland Foot Score and radiologically with radiographs and CT scans, evaluated according to the Score Analysis of Verona. The clinical results at follow-up were excellent or good in 49 cases (90.7%), fair in two (3.7%) and poor in three (5.6%). The mean pre-operative Böhler's angle was 6.98 degrees (5.95 degrees to 19.86 degrees), whereas after surgery the mean value was 21.94 degrees (12.58 degrees to 31.30 degrees) (p < 0.01). Excellent results on CT scanning were demonstrated in 24 cases (44.4%), good in 25 (46.3%), fair in three (5.6%) and poor in two (3.7%). Transient local osteoporosis was observed in ten patients (18.5%), superficial pin track infection in three (5.6%), and three patients (5.6%) showed thalamic displacement following unadvised early weight-bearing. The clinical results appear to be comparable with those obtainable with open reduction and internal fixation, with the advantages of reduced risk using a minimally-invasive technique.

  17. Management of Open Tibial Shaft Fractures: Does the Timing of Surgery Affect Outcomes?

    PubMed

    Duyos, Oscar A; Beaton-Comulada, David; Davila-Parrilla, Ariel; Perez-Lopez, Jose Carlos; Ortiz, Krystal; Foy-Parrilla, Christian; Lopez-Gonzalez, Francisco

    2017-03-01

    Open tibial shaft fractures require emergent care. Treatment with intravenous antibiotics and fracture débridement within 6 to 24 hours is recommended. Few studies have examined outcomes when surgical treatment is performed >24 hours after occurrence of the fracture. This retrospective study included 227 patients aged ≥18 years with isolated open tibial shaft fractures in whom the time to initial débridement was >24 hours. The statistical analysis was based on time from injury to surgical débridement, Gustilo-Anderson classification, method of fixation, union status, and infection status. Fractures débrided within 24 to 48 hours and 48 to 96 hours after injury did not show a statistically significant difference in terms of infection rates (P = 0.984). External fixation showed significantly greater infection rates (P = 0.044) and nonunion rates (P = 0.001) compared with intramedullary nailing. Open tibial shaft fractures should be débrided within 24 hours after injury. Our data indicate that after the 24-hour period and up to 4 days, the risk of infection remains relatively constant independent of the time to débridement. Patients treated with external fixation had more complications than did patients treated with other methods of fixation. Primary reamed intramedullary nailing appears to be a reasonable option for the management of Gustilo-Anderson types 1 and 2 open tibial shaft fractures. Level III retrospective study.

  18. Computer-aided surgical planner for a new bone deformity correction device using axis-angle representation.

    PubMed

    Wu, Ying Ying; Plakseychuk, Anton; Shimada, Kenji

    2014-11-01

    Current external fixators for distraction osteogenesis (DO) are unable to correct all types of deformities in the lower limb and are difficult to use because of the lack of a pre-surgical planning system. We propose a DO system that consists of a surgical planner and a new, easy-to-setup unilateral fixator that not only corrects all lower limb deformity, but also generates the contralateral/predefined bone shape. Conventionally, bulky constructs with six or more joints (six degrees of freedom, 6DOF) are needed to correct a 3D deformity. By applying the axis-angle representation, we can achieve that with a compact construct with only two joints (2DOF). The proposed system makes use of computer-aided design software and computational methods to plan and simulate the planned procedure. Results of our stress analysis suggest that the stiffness of our proposed fixator is comparable to that of the Orthofix unilateral external fixator. We tested the surgical system on a model of an adult deformed tibia and the resulting bone trajectory deviates from the target bone trajectory by 1.8mm, which is below our defined threshold error of 2mm. We also extracted the transformation matrix that defines the deformity from the bone model and simulated the planned procedure. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Surgical Removal of Neglected Soft Tissue Foreign Bodies by Needle-Guided Technique

    PubMed Central

    Ebrahimi, Ali; Radmanesh, Mohammad; Rabiei, Sohrab; kavoussi, Hossein

    2013-01-01

    Introduction: The phenomenon of neglected foreign bodies is a significant cause of morbidity in soft tissue injuries and may present to dermatologists as delayed wound healing, localized cellulitis and inflammation, abscess formation, or foreign body sensation. Localization and removal of neglected soft tissue foreign bodies (STFBs) is complex due to possible inflammation, indurations, granulated tissue, and fibrotic scar. This paper describes a simple method for the quick localization and (surgical) removal of neglected STFBs using two 23-gauge needles without ultrasonographic or fluoroscopic guidance. Materials and Methods: A technique based on the use of two 23-gauge needles was used in 41 neglected STFBs in order to achieve proper localization and fixation of foreign bodies during surgery. Results: Surgical removal was successful in 38 of 41 neglected STFBs (ranging from 2–13mm in diameter). Conclusion: The cross-needle-guided technique is an office-based procedure that allows the successful surgical removal of STFBs using minimal soft tissue exploration and dissection via proper localization, fixation, and propulsion of the foreign body toward the surface of the skin. PMID:24303416

  20. The Use of a Multiplanar, Multi-Axis External Fixator to Achieve Knee Arthrodesis in a Worst Case Scenario: A Case Series

    PubMed Central

    Raskolnikov, Dima; Slover, James D.; Egol, Kenneth A.

    2013-01-01

    Background One of the most catastrophic outcomes following total knee arthroplasty (TKA) is a chronic periprosthetic infection with concomitant failure of the knee extensor mechanism. This study retrospectively reviewed the clinical records of 7 patients who were treated with a 6 axis circular external fixation frame (Taylor Spatial Frame (TSF)) for this condition. Fusion was achieved in 5 of 7 patients (71%) at an average of 8.4 months after surgery. Complications occurred in the treatment of 5 of 7 patients (71%). Infection was controlled in all cases. The TSF presents another valuable tool, which the orthopaedic surgeon should consider when treating these difficult cases. Purpose To evaluate the use of the Taylor Spatial Frame (TSF) to achieve knee arthrodesis in patients with chronically infected total knee arthroplasties (TKAs) with concomitant failure of the knee extensor mechanism. Methods We retrospectively evaluated the clinical records of 7 patients who were referred to our tertiary care orthopaedic medical center with multiple failed knee arthroplasties, chronic draining infection and complete loss of the extensor mechanism. All patients were treated with a similar protocol including, debridement and bony stabilization with an adjustable, 6 axis circular external fixation frame (TSF). Hospital charts were reviewed for sociodemographic information, surgical details, hospital course and complications. Radiographs were reviewed for healing and alignment. Follow up included clinical examination and radiographs. Results The mean age of the patients was 70.9 years (range, 59 – 83 years) at the time of application of the TSF. There were 3 men and 4 women. The average time between TKA and diagnosis of infection was 30.7 months (range, 2.6 – 67.0 months). The 7 patients had undergone an average of 3.3 prior surgical procedures (range, 2-4 procedures) on the ipsilateral extremity. Fusion was achieved in 5 of 7 patients (71%) at an average of 8.4 months after surgery (range, 6 – 10.5 months). Complications occurred in the treatment of 5 of 7 patients (71%) and included infection at the site of the pin tracks (5 patients), antibiotic- induced acute renal failure (1 patient), wound breakdown requiring flap closure (1 patient), and femur fracture secondary to a fall after placement of the antibiotic spacer but before application of the TSF (1 patient). The 2 patients in whom failure of fusion occurred returned to ambulation with an assistive device. Infection was controlled in all cases. Conclusion Fusion and complication rates in this cohort are comparable to those reported in previous studies using other techniques to achieve external fixation. The TSF is a versatile external fixator that offers another tool, which the orthopaedic surgeon should consider when treating these difficult cases. PMID:24027456

  1. Bovine xenograft application for treatment of a metatarsal nonunion fracture in an alpaca (Vicugna pacos).

    PubMed

    Longo, F; Finotti, L; Bellini, L; Zavan, B; Busetto, R; Isola, M

    2016-05-01

    A 15-year-old female huacaya alpaca (Vicugna pacos) was referred because of a non-weight-bearing lameness (4/4) in the left pelvic limb caused by a grade three open metatarsal fracture. The referring veterinarian treated the fracture with conservative management using bandages, but it progressively evolved to a non-union. Clinical examination revealed external wounds on the medial and lateral surfaces of the metatarsus. Radiographs confirmed an open, nonarticular, displaced, diaphyseal fracture of the left metatarsus. Cancellous bone was sourced from bovine proximal and distal femur epiphyses, followed by a thermal shock procedure to achieve decellularisation, to produce a xenograft. Open reduction and internal fixation of the fracture using locking plates was performed. Alignment of the fracture fragments was corrected and the xenograft was placed at the debrided fracture site to stimulate and harness osteogenesis in situ. Clinical and radiographic follow-up was performed up to 40 weeks postoperatively. Clinical evaluations revealed that the alpaca gradually increased weight bearing following bandage removal 10 days after surgery. Serial radiographs showed correct alignment of the left metatarsus, progressive bone modelling and, complete bone union at 12 weeks. Ten months postoperatively the alpaca showed no signs of lameness and resumed normal activity. For management of a metatarsal non-union, a combination of bovine xenograft application and angular stable internal fixation progressed toward an excellent long-term recovery.

  2. Acceleration and holographic studies on different types of dynamization of external fixators of the bones

    NASA Astrophysics Data System (ADS)

    Podbielska, Halina; Kasprzak, Henryk T.; Voloshin, Arkady S.; Pennig, Dietmar; von Bally, Gert

    1992-08-01

    The unilateral axially dynamic fixator (Orthofix) was mounted on a sheep tibial shaft. Three fixation modes: static, dynamic controlled, and dynamic free were examined by means of double exposure holographic interferometry. Simultaneously, the acceleration was measured by an accelerometer and displayed on the monitor together with loading characteristics. The first exposure was made before the acting force was applied to the tibia plateau. The second one after the moment when the acceleration wave started to propagate through the specimen. We stated that in the case of dynamization less torsion occurs at the fracture site. So far, we have not been able to determine any correlation between results of holographic and accelerometric measurements.

  3. Contributions of retinal input and phenomenal representation of a fixation object to the saccadic gap effect.

    PubMed

    Ueda, Hiroshi; Takahashi, Kohske; Watanabe, Katsumi

    2013-04-19

    The saccadic "gap effect" refers to a phenomenon whereby saccadic reaction times (SRTs) are shortened by the removal of a visual fixation stimulus prior to target presentation. In the current study, we investigated whether the gap effect was influenced by retinal input of a fixation stimulus, as well as phenomenal permanence and/or expectation of the re-emergence of a fixation stimulus. In Experiment 1, we used an occluded fixation stimulus that was gradually hidden by a moving plate prior to the target presentation, which produced the impression that the fixation stimulus still remained and would reappear from behind the plate. We found that the gap effect was significantly weakened with the occluded fixation stimulus. However, the SRT with the occluded fixation stimulus was still shorter in comparison to when the fixation stimulus physically remained on the screen. In Experiment 2, we investigated whether this effect was due to phenomenal maintenance or expectation of the reappearance of the fixation stimulus; this was achieved by using occluding plates that were an identical color to the background screen, giving the impression of reappearance of the fixation stimulus but not of its maintenance. The result showed that the gap effect was still weakened by the same degree even without phenomenal maintenance of the fixation stimulus. These results suggest that the saccadic gap effect is modulated by both retinal input and subjective expectation of re-emergence of the fixation stimulus. In addition to oculomotor mechanisms, other components, such as attentional mechanisms, likely contribute to facilitation of the subsequent action. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. [Missed diagnosis of hiding posterior marginal fracture of ankle with pronation-external rotation type and its treatment].

    PubMed

    Wang, Jia; Zhang, Yun-Tong; Zhang, Chun-Cai; Tang, Yang

    2014-01-01

    To analyze causes of missed diagnosis of hiding post-malleolar fractures in treating ankle joint fractures of pronation-external rotation type according to Lauge-Hansen classification and assess its medium-term outcomes. Among 103 patients with ankle joint fracture of pronation-external rotation type treated from March 2002 to June 2010,9 patients were missed diagnosis,including 6 males and 3 females,with a mean age of 35.2 years old (ranged, 18 to 55 years old) . Four patients were diagnosed during operation, 2 patients were diagnosed 2 or 3 days after first surgery and 3 patients came from other hospital. All the patients were treated remedially with lag screws and lock plates internal fixation. After operation,ankle joint function was evaluated according to American Orthopaedic Foot and Ankle Society (AOFAS). All the 9 patients were followed up, and the duration ranged from 14 to 30 months (averaged, 17 months). No incision infection was found, and all incision healed at the first stage. At the latest follow-up, AOFAS was 83.0 +/- 4.4, the score of 4 patients diagnosed during operation was 85.0 +/- 2.9, and the score of 5 patients treated by secondary operation was 81.0 +/- 5.3. All the patients got fracture union observed by X-ray at a mean time of 2.2 months after operation. There were no complications such as internal fixation loosing, broken and vascular or nerve injuries. Ankle joint fracture of pronation-external rotation type may be combined with hiding post-malleolar fractures. So to patients with ankle joint fracture of pronation-external rotation type, lateral X-ray should be read carefully, and if necessary, CT or MRI examination should be performed. If adding lateral X-ray examination after reduction of exterior and interior ankle joint fixation, the missed diagnosis may be avoided.

  5. A technique for correction of equinus contracture using a wire fixator and elastic tension.

    PubMed

    Melvin, J Stuart; Dahners, Laurence E

    2006-02-01

    Equinus contracture often is a complication of trauma, burns, or neurologic deficit. Many patients with contractures secondary to trauma or burns have poor soft tissue, which makes invasive correction a less appealing option. The Ilizarov external fixator has been used as a less invasive attempt to correct equinus contracture. We describe our "dynamic" technique and present a clinical patient series using a variation of the unconstrained Ilizarov technique, which uses elastic bands rather than threaded rods to supply the corrective force.

  6. An alternative technique for transosseous calcaneal pinning in external fixation.

    PubMed

    DiDomenico, Lawrence A; Giagnacova, Albert; Cross, Davina J; Ziran, Bruce H

    2012-01-01

    The authors describe a technique in which two 5.5-mm pins are inserted from the posterior aspect of the calcaneus and advanced anteriorly on a slightly convergent vector. The 2 points of fixation, with a 5/8 ring, provide a "steering wheel" effect allowing for leverage and control of the hindfoot and ankle. The construct also allows for offloading of the posterior calcaneus. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Factors Associated With Revision Surgery After Internal Fixation of Hip Fractures.

    PubMed

    Sprague, Sheila; Schemitsch, Emil H; Swiontkowski, Marc; Della Rocca, Gregory J; Jeray, Kyle J; Liew, Susan; Slobogean, Gerard P; Bzovsky, Sofia; Heels-Ansdell, Diane; Zhou, Qi; Bhandari, Mohit

    2018-05-01

    Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (for every 5-point increase) (HR 1.19, 95% CI 1.02-1.39; P = 0.027), displaced fracture (HR 2.16, 95% CI 1.44-3.23; P < 0.001), unacceptable quality of implant placement (HR 2.70, 95% CI 1.59-4.55; P < 0.001), and smokers treated with cancellous screws versus smokers treated with a sliding hip screw (HR 2.94, 95% CI 1.35-6.25; P = 0.006). Additionally, for every 10-year decrease in age, participants experienced an average increased risk of 39% for hardware removal. Results of this study may inform future research by identifying high-risk patients who may be better treated with arthroplasty and may benefit from adjuncts to care (HR 1.39, 95% CI 1.05-1.85; P = 0.020). Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

  8. Displaced Neer Type IIB distal-third clavicle fractures-Long-term clinical outcome after plate fixation and additional screw augmentation for coracoclavicular instability.

    PubMed

    Tiefenboeck, Thomas M; Boesmueller, Sandra; Binder, Harald; Bukaty, Adam; Tiefenboeck, Michael M; Joestl, Julian; Hofbauer, Marcus; Ostermann, Roman C

    2017-01-23

    Unstable Neer Type IIB fractures require meticulous surgical treatment. Thus, the aim of this study was to present long-term outcomes after plate fixation and minimally invasive coracoclavicular (CC) stabilization using screw fixation. A consecutive series of patients with unstable Neer Type IIB displaced clavicle fractures, treated by open reduction and internal fixation (ORIF) with a plate and additional screw fixation for coracoclavicular ligament instability, was reviewed in order to determine long-term clinical and radiological outcome. Seven patients, six males and one female, with a mean age of 37 ± 8 years (median: 36 years; range, 28-51 years), were evaluated. At latest follow-up, after a mean of 67 months (range, 11-117 months), patients presented with the following mean scores: DASH: 0.57, ASES: 98.81, UCLA: 34.29, VAS: 0.43, Simple Shoulder Test: 11.57. However, two complications were observed: one case of implant loosening and one non-union. There were no differences observed between the CC distances comparing postoperative X-rays to those in final follow-up. In 25% of our patients early postoperative complications occurred. In all patients reoperation was necessary to remove the implanted screw. The results of the present study indicate that the treatment of Neer Type IIB lateral clavicle fractures with ORIF using a plate and additional CC screw fixation, leads to satisfying clinical and radiological outcomes in the long-term. However, considering an early postoperative complication rate of 25% and a 100% rate of secondary surgery due to removal of the CC screw does not seem to justify this technique anymore.

  9. Anterior-inferior tibiofibular ligament anatomical repair and augmentation versus trans-syndesmosis screw fixation for the syndesmotic instability in external-rotation type ankle fracture with posterior malleolus involvement: A prospective and comparative study.

    PubMed

    Zhan, Yu; Yan, Xiaoyu; Xia, Ronggang; Cheng, Tao; Luo, Congfeng

    2016-07-01

    Syndesmosis injury is common in external-rotation type ankle fractures (ERAF). Trans-syndesmosis screw fixation, the gold-standard treatment, is currently controversial for its complications and biomechanical disadvantages. The purpose of this study was to introduce a new method of anatomically repairing the anterior-inferior tibiofibular ligament (AITFL) and augmentation with anchor rope system to treat the syndesmotic instability in ERAF with posterior malleolus involvement and to compare its clinical outcomes with that of trans-syndesmosis screw fixation. 53 ERAFs with posterior malleolus involvement received surgery, and the syndesmosis was still unstable after fracture fixation. They were randomised into screw fixation group and AITFL anatomical repair with augmentation group. Reduction quality, syndesmosis diastasis recurrence, pain (VAS score), time back to work, Olerud-Molander ankle score and range of motion (ROM) of ankle were investigated. Olerud-Molander score in AITFL repair group and screw group was 90.4 and 85.8 at 12-month follow-up (P>0.05). Plantar flexion was 31.2° and 34.3° in repair and screw groups (P=0.04). Mal-reduction happened in 5 cases (19.2%) in screw group while 2 cases (7.4%) in repair group. Postoperative syndesmosis re-diastasis occurred in 3 cases in screw group while zero in repair group (P>0.05). Pain score was similar between the two groups (P>0.05). Overall complication rate and back to work time were 26.9% and 3.7% (P=0.04), 7.15 months and 5.26 months (P=0.02) in screw group and repair group, respectively. For syndesmotic instability in ERAF with posterior malleolus involvement, the method of AITFL anatomical repair and augmentation with anchor rope system had an equivalent functional outcome and reduction, earlier rehabilitation and less complication compared with screw fixation. It can be selected as an alternative. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Torsional stiffness after subtalar arthrodesis using second generation headless compression screws: Biomechanical comparison of 2-screw and 3-screw fixation.

    PubMed

    Riedl, Markus; Glisson, Richard R; Matsumoto, Takumi; Hofstaetter, Stefan G; Easley, Mark E

    2017-06-01

    Subtalar joint arthrodesis is a common operative treatment for symptomatic subtalar arthrosis. Because excessive relative motion between the talus and calcaneus can delay or prohibit fusion, fixation should be optimized, particularly in patients at risk for subtalar arthrodesis nonunion. Tapered, fully-threaded, variable pitch screws are gaining popularity for this application, but the mechanical properties of joints fixed with these screws have not been characterized completely. We quantified the torsion resistance of 2-screw and 3-screw subtalar joint fixation using this type of screw. Ten pairs of cadaveric subtalar joints were prepared for arthrodesis and fixed using Acutrak 2-7.5 screws. One specimen from each pair was fixed with two diverging posterior screws, and the contralateral joint was fixed using two posterior screws and a third screw directed through the anterior calcaneus into the talar neck. Internal and external torsional loads were applied and joint rotation and torsional stiffness were measured at two torque levels. Internal rotation was significantly less in specimens fixed with three screws. No difference was detectable between 2-screw and 3-screw fixation in external rotation or torsional stiffness in either rotation direction. Both 2-screw and 3-screw fixation exhibited torsion resistance surpassing that reported previously for subtalar joints fixed with two diverging conventional lag screws. Performance of the tapered, fully threaded, variable pitch screws exceeded that of conventional lag screws regardless of whether two or three screws were used. Additional resistance to internal rotation afforded by a third screw placed anteriorly may offer some advantage in patients at risk for nonunion. Copyright © 2017. Published by Elsevier Ltd.

  11. Clinical efficacy and safety of limited internal fixation combined with external fixation for Pilon fracture: A systematic review and meta-analysis.

    PubMed

    Zhang, Shao-Bo; Zhang, Yi-Bao; Wang, Sheng-Hong; Zhang, Hua; Liu, Peng; Zhang, Wei; Ma, Jing-Lin; Wang, Jing

    2017-04-01

    To compare the clinical efficacy and complications of limited internal fixation combined with external fixation (LIFEF) and open reduction and internal fixation (ORIF) in the treatment of Pilon fracture. We searched databases including Pubmed, Embase, Web of science, Cochrane Library and China Biology Medicine disc for the studies comparing clinical efficacy and complications of LIFEF and ORIF in the treatment of Pilon fracture. The clinical efficacy was evaluated by the rate of nonunion, malunion/delayed union and the excellent/good rate assessed by Mazur ankle score. The complications including infections and arthritis symptoms after surgery were also investigated. Nine trials including 498 pilon fractures of 494 patients were identified. The meta-analysis found no significant differences in nonunion rate (RR = 1.60, 95% CI: 0.66 to 3.86, p = 0.30), and the excellent/good rate (RR = 0.95, 95% CI: 0.86 to 1.04, p = 0.28) between LIFEF group and ORIF group. For assessment of infections, there were significant differences in the rate of deep infection (RR = 2.18, 95% CI: 1.34 to 3.55, p = 0.002), and the rate of arthritis (RR = 1.26, 95% CI: 1.03 to 1.53, p = 0.02) between LIFEF group and ORIF group. LIFEF has similar effect as ORIF in the treatment of pilon fractures, however, LIFEF group has significantly higher risk of complications than ORIF group does. So LIFEF is not recommended in the treatment of pilon fracture. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  12. One lesson from arthroplasty to osseointegration in search for better fixation of in-bone implanted prosthesis

    PubMed Central

    Pitkin, Mark

    2011-01-01

    Direct transcutaneous prosthetic attachment (osseointegration) consists of implanting directly into the residuum bone a metal pylon whose external fraction connects the residuum to the external prosthesis. Since the introduction of osseointegration about 20 years ago, the obvious challenge associated with this technology has been the skin-pylon interface as a source of infections. In comparison, the bone-device interface was considered less problematic because of the knowledge and experience inherited from dental implantology and total joint replacement (arthroplasty). Current methods of pylon fixation in osseointegration follow arthroplasty’s paradigm of positioning the pylon’s shaft inside the bone’s medullary canal. However, adopting the medullary canal as a holding compartment for the pylon’s shaft creates the problem of shaft loosening, which has not yet been solved in arthroplasty. PMID:18712634

  13. The Effect of Insertion Technique on Temperatures for Standard and Self-Drilling External Fixation Pins.

    PubMed

    Manoogian, Sarah; Lee, Adam K; Widmaier, James C

    2017-08-01

    No studies have assessed the effects of parameters associated with insertion temperature in modern self-drilling external fixation pins. The current study assessed how varying the presence of irrigation, insertion speed, and force impacted the insertion temperatures of 2 types of standard and self-drilling external fixation half pins. Seventy tests were conducted with 10 trials for 4 conditions on self-drilling pins, and 3 conditions for standard pins. Each test used a thermocouple inside the pin to measure temperature rise during insertion. Adding irrigation to the standard pin insertion significantly lowered the maximum temperature (P <0.001). Lowering the applied force for the standard pin did not have a significant change in temperature rise. Applying irrigation during the self-drilling pin tests dropped average rise in temperature from 151.3 ± 21.6°C to 124.1 ± 15.3°C (P = 0.005). When the self-drilling pin insertion was decreased considerably from 360 to 60 rpm, the temperature decreased significantly from 151.3 ± 21.6°C to 109.6 ± 14.0°C (P <0.001). When the force applied increased significantly, the corresponding self-drilling pin temperature increase was not significant. The standard pin had lower peak temperatures than the self-drilling pin for all conditions. Moreover, slowing down the insertion speed and adding irrigation helped mitigate the temperature increase of both pin types during insertion.

  14. Influence of meditation on anti-correlated networks in the brain

    PubMed Central

    Josipovic, Zoran; Dinstein, Ilan; Weber, Jochen; Heeger, David J.

    2012-01-01

    Human experiences can be broadly divided into those that are external and related to interaction with the environment, and experiences that are internal and self-related. The cerebral cortex appears to be divided into two corresponding systems: an “extrinsic” system composed of brain areas that respond more to external stimuli and tasks and an “intrinsic” system composed of brain areas that respond less to external stimuli and tasks. These two broad brain systems seem to compete with each other, such that their activity levels over time is usually anti-correlated, even when subjects are “at rest” and not performing any task. This study used meditation as an experimental manipulation to test whether this competition (anti-correlation) can be modulated by cognitive strategy. Participants either fixated without meditation (fixation), or engaged in non-dual awareness (NDA) or focused attention (FA) meditations. We computed inter-area correlations (“functional connectivity”) between pairs of brain regions within each system, and between the entire extrinsic and intrinsic systems. Anti-correlation between extrinsic vs. intrinsic systems was stronger during FA meditation and weaker during NDA meditation in comparison to fixation (without mediation). However, correlation between areas within each system did not change across conditions. These results suggest that the anti-correlation found between extrinsic and intrinsic systems is not an immutable property of brain organization and that practicing different forms of meditation can modulate this gross functional organization in profoundly different ways. PMID:22287947

  15. Distraction for proximal interphalangeal joint contractures: long-term results.

    PubMed

    Houshian, Shirzad; Jing, Shan Shan; Kazemian, Gholam Hussein; Emami-Moghaddam-Tehrani, Mohammad

    2013-10-01

    To report the medium- to long-term outcomes of joint distraction using a unilateral external fixator in the treatment of chronic post-traumatic proximal interphalangaeal (PIP) joint contractures. Between September 2001 and October 2011, 94 consecutive patients (98 PIP joints) with a mean age of 43 years (range, 17-69 y) were treated with external fixation for chronic flexion deformity of the PIP joint from trauma. The average time from injury to surgery was 48 months (range, 6-84 mo), and the duration of joint distraction was 10 days (range, 7-22 d). Patients were followed for a mean period of 54 months (range, 12-72 mo). The average gain in joint flexion was 25° and in joint extension was 40°. The mean improvement in the active range of movement was 67° (range. 30°-90°). There was no loss of motion on the latest follow-up. Patients younger than 40 years fared slightly better than those older than 40 years. Two patients developed swelling, pain, and erythema during treatment, which resolved upon temporarily stopping the distraction process. There were 12 cases of superficial pin-site infections, which were managed conservatively without serious complications or adverse outcome. External fixation is a simple and effective treatment modality for chronic traumatic PIP joint contractures with good predictable medium- to long-term results. Careful patient selection and monitoring are required. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  16. Limb saving surgery for Ewing's sarcoma of the distal tibia: a case report.

    PubMed

    Mizoshiri, Naoki; Shirai, Toshiharu; Terauchi, Ryu; Tsuchida, Shinji; Mori, Yuki; Katsuyama, Yusei; Hayashi, Daichi; Oka, Yoshinobu; Kubo, Toshikazu

    2018-05-02

    Ewing's sarcoma is a primary malignant tumor of bone occurring mostly in childhood. Few effective reconstruction techniques are available after wide resection of Ewing's sarcoma at the distal end of the tibia. Reconstruction after wide resection is especially difficult in children, as it is necessary to consider the growth and activity of the lower limbs. A 12-year-old Japanese boy had presented with right lower leg pain at age 8 years. Imaging examination showed a bone tumor accompanied by a large extra-skeletal mass in the distal part of his tibia. The tumor was histologically diagnosed as Ewing's sarcoma. The patient received chemotherapy, followed by wide resection. Reconstruction consisted of a bone transport method involving external fixation of Taylor Spatial Frame. To prevent infection after surgery, the external fixation pin was coated with iodine. One year after surgery, the patient showed poor consolidation of bone, so iliac bone transplantation was performed on the extended bones and docking site of the distal tibia. After 20 months, tibia formation was good. Three years after surgery, there was no evidence of tumor recurrence or metastases; bone fusion was good, and he was able to run. The bone transport method is an effective surgical method of reconstruction after wide resection of a bone tumor at the distal end of the tibia, if a pin can be inserted into the distal bone fragment. Coating external fixation pins with iodine may prevent postoperative infection.

  17. Semi-automated intra-operative fluoroscopy guidance for osteotomy and external-fixator.

    PubMed

    Lin, Hong; Samchukov, Mikhail L; Birch, John G; Cherkashin, Alexander

    2006-01-01

    This paper outlines a semi-automated intra-operative fluoroscopy guidance and monitoring approach for osteotomy and external-fixator application in orthopedic surgery. Intra-operative Guidance module is one component of the "LegPerfect Suite" developed for assisting the surgical correction of lower extremity angular deformity. The Intra-operative Guidance module utilizes information from the preoperative surgical planning module as a guideline to overlay (register) its bone outline semi-automatically with the bone edge from the real-time fluoroscopic C-Arm X-Ray image in the operating room. In the registration process, scaling factor is obtained automatically through matching a fiducial template in the fluoroscopic image and a marker in the module. A triangle metal plate, placed on the operating table is used as fiducial template. The area of template image within the viewing area of the fluoroscopy machine is obtained by the image processing techniques such as edge detection and Hough transformation to extract the template from other objects in the fluoroscopy image. The area of fiducial template from fluoroscopic image is then compared with the area of the marker from the planning so as to obtain the scaling factor. After the scaling factor is obtained, the user can use simple operations by mouse to shift and rotate the preoperative planning to overlay the bone outline from planning with the bone edge from fluoroscopy image. In this way osteotomy levels and external fixator positioning on the limb can guided by the computerized preoperative plan.

  18. The Muslim Headscarf and Face Perception: “They All Look the Same, Don't They?”

    PubMed Central

    Toseeb, Umar; Bryant, Eleanor J.; Keeble, David R. T.

    2014-01-01

    The headscarf conceals hair and other external features of a head (such as the ears). It therefore may have implications for the way in which such faces are perceived. Images of faces with hair (H) or alternatively, covered by a headscarf (HS) were used in three experiments. In Experiment 1 participants saw both H and HS faces in a yes/no recognition task in which the external features either remained the same between learning and test (Same) or switched (Switch). Performance was similar for H and HS faces in both the Same and Switch condition, but in the Switch condition it dropped substantially compared to the Same condition. This implies that the mere presence of the headscarf does not reduce performance, rather, the change between the type of external feature (hair or headscarf) causes the drop in performance. In Experiment 2, which used eye-tracking methodology, it was found that almost all fixations were to internal regions, and that there was no difference in the proportion of fixations to external features between the Same and Switch conditions, implying that the headscarf influenced processing by virtue of extrafoveal viewing. In Experiment 3, similarity ratings of the internal features of pairs of HS faces were higher than pairs of H faces, confirming that the internal and external features of a face are perceived as a whole rather than as separate components. PMID:24520313

  19. Projections of Biofuel Growth Patterns Reveal the Potential Importance of Nitrogen Fixation for Miscanthus Productivity

    NASA Astrophysics Data System (ADS)

    Davis, S. C.; Parton, W. J.; Dohleman, F. G.; Gottel, N. R.; Smith, C. M.; Kent, A. D.; Delucia, E. H.

    2008-12-01

    Demand for liquid biofuels is increasing because of the disparity between fuel demand and supply. Relative to grain crops, the more intensive harvest required for second generation liquid biofuel production leads to the removal of significantly more carbon and nitrogen from the soil. These elements are conventionally litter products of crops that are returned to the soil and can accumulate over time. This loss of organic matter represents a management challenge because the energy cost associated with fertilizers or external sources of organic matter reduce the net energy value of the biofuel crops. Plants that have exceptional strategies for exploiting nutrients may be the most viable options for sustainable biofuel yields because of low management and energy cost. Miscanthus x giganteus has high N retranslocation rates, maintains high photosynthetic rates over a large temperature range, exploits a longer-than-average growing season, and yields at least twice the biomass of other candidate biofuel grass crops (i.e. switchgrass). We employed the DAYCENT model to project potential productivity of Miscanthus, corn, switchgrass, and mixed prairie communities based on our current knowledge of these species. Ecosystem process descriptions that have been validated for many crop species did not accurately predict Miscanthus yields and lead to new hypotheses about unknown N cycling mechanisms for this species. We tested the hypothesis that Miscanthus hosts N-fixing bacteria in several ways. First, we used enrichment culture and molecular methods to detect N-fixing bacteria in Miscanthus. Then, we demonstrated the plant-growth promoting effect of diazotrophs isolated from Miscanthus rhizomes on a model grass. And finally, we applied 15N2 to the soil and rooting zone of field grown Miscanthus plants to determine if atmospheric N2 was incorporated into plant tissue, a process that requires N-fixation. These experiments are the first tests of N-fixation in Miscanthus x giganteus, and the ecosystem model allowed us to project how much nitrogen may be obtained from N-fixation to support sustainable high biomass yields.

  20. Knee arthrodesis using a short locked intramedullary nail. A new technique.

    PubMed

    Cheng, S L; Gross, A E

    1995-01-01

    This article reports on the use of a new intramedullary nail designed specifically for fixation of knee fusions. The nail is a short locked stainless steel nail that is inserted through a single anterior knee incision and uses an outrigger targeting rod to guide the insertion of the locking screws. The successful use of this technique is illustrated in two cases. The advantages of this nail compared with previously reported techniques of fixation for knee fusions are that the short locked nail avoids the second incision required for the insertion of long knee fusion nails, the bulkiness of the double plating technique in the relatively subcutaneous anterior knee area, and the difficulties inherent with the prolonged use of pins for external fixation.

  1. Knee arthrodesis.

    PubMed

    MacDonald, James H; Agarwal, Sanjeev; Lorei, Matthew P; Johanson, Norman A; Freiberg, Andrew A

    2006-03-01

    Arthrodesis is one of the last options available to obtain a stable, painless knee in a patient with a damaged knee joint that is not amenable to reconstructive measures. Common indications for knee arthrodesis include failed total knee arthroplasty, periarticular tumor, posttraumatic arthritis, and chronic sepsis. The primary contraindications to knee fusion are bilateral involvement or an ipsilateral hip arthrodesis. A variety of techniques has been described, including external fixation, internal fixation by compression plates, intramedullary fixation through the knee with a modular nail, and antegrade nailing through the piriformis fossa. Allograft or autograft may be necessary to restore lost bone stock or to augment fusion. For the carefully selected patient with realistic expectations, knee arthrodesis may relieve pain and obviate the need for additional surgery or extensive postoperative rehabilitation.

  2. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: a series of 10 cases and surgical guidelines.

    PubMed

    Joshi, Samir; Kshirsagar, Rajesh; Mishra, Akshay; Shah, Rahul

    2015-01-01

    To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. All cases showed satisfactory bone healing without any growth disturbance. Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  3. Management of Late Onset Perthes: Evaluation of Distraction by External Fixator—5-Year Follow-Up

    PubMed Central

    Srivastava, Rajeshwar N.; Shukla, Prashant; Pushkar, Amit; Ali, Sabir

    2014-01-01

    Background. Hip distraction in Perthes' disease unloads the joint, which negates the harmful effect of the stresses on the articular surfaces, which may promote the sound healing of the area of necrosis. We have examined the effect of arthrodiastasis on the preservation of the femoral head in older children with Perthes' disease. Methods and Materials. Twelve children with age more than 8 years with Perthes' disease of less than one year were treated with hip distraction by a hinged monolateral external fixator. Observation and Results. Mean duration of distraction was 13.9 days. These children were evaluated by clinicoradiological parameters for a mean period of 32.4 months. There was a significant improvement in the range of movements and mean epiphyseal index, but the change in the percentage of uncovered head femur was insignificant. There was significant improvement in Harris Hip score. Conclusions. Hip distraction by hinged monolateral external fixator seems to be a valid treatment option in cases with Perthes' disease in the selected group of patients, where poor results are expected from conventional treatment. PMID:25580302

  4. Treatment outcomes of open pelvic fractures associated with extensive perineal injuries.

    PubMed

    Hasankhani, Ebrahim Ghayem; Omidi-Kashani, Farzad

    2013-12-01

    The main causes of death in patients with open pelviperineal injuries are uncontrollable bleeding and pelvic sepsis. The aim of this study was to evaluate the management outcomes of open pelvic fractures associated with extensive perineal injuries. We retrospectively studied 15 cases with open pelvic fractures associated with extensive perineal injuries (urethral and anal canal laceration) admitted between August 2006 and September 2010. Mechanism of injury, Injury Severity Score, associated injuries, hemodynamic status on arrival, resuscitation and transfusion requirements, operative techniques, intra- and postoperative complications, length of intensive care unit and hospital stay, and mortality were recorded in a computerised database for further evaluation and analysis. The male to female ratio was 12:3 with an average age of 38.6 years (ranged, 11 to 65 years). The average packed red blood cell units used were 8 units (ranged, 4 to 21 units). All patients were initially transferred to the operating room for colostomy, radical debridement and fixation of the pelvic fracture by an external fixator. One patient had acute renal failure, which improved with medical treatment and 2 patients (13.3%) died, one with type III anteroposterior compression fracture due to hemorrhagic shock and the other due to septicemia. Open pelvic fractures with extensive perineal injuries are associated with high mortality rates. Early diagnosis and appropriate treatment, including reanimation, colostomy, cystostomy, vigorous and repeated irrigation and debridement, and fixation by an external fixator can improve the outcomes and reduce the mortality rate.

  5. Combined Internal and External Fixation for Diabetic Charcot Reconstruction: A Retrospective Case Series.

    PubMed

    Hegewald, Kenneth W; Wilder, Megan L; Chappell, Todd M; Hutchinson, Byron L

    2016-01-01

    Diabetic Charcot neuroarthropathy is a complex, limb-threatening disease process with major lifestyle-altering repercussions for patients. When Charcot neuroarthropathy leads to unstable deformity, ulceration, and potential infection despite conservative therapies, foot and ankle surgeons often consider reconstructive limb salvage procedures to restore function. The purpose of the present study was to evaluate the clinical and radiographic outcomes of diabetic Charcot reconstruction using combined internal and external fixation. A total of 22 patients were reviewed; 16 (72.73%) midfoot and 6 (27.27%) tibiotalocalcaneal arthrodesis procedures were consecutively performed from March 2009 to May 2013. All surgical procedures were performed in nonacute phases of the Charcot process in patients with diagnosed diabetes mellitus and documented peripheral neuropathy. Patients were excluded from the study if they were not diabetic despite having undergone Charcot reconstruction, regardless of the fixation method, or if they did not complete radiographic imaging. During a mean follow-up period of 58.60 ± 42.37 (range 16 to 164) weeks, limb salvage was achieved in 20 patients (90.91%), and 2 (9.09%) required below-the-knee amputation at a mean of 42 ± 14.14 weeks. Wound dehiscence occurred in 8 (36.36%), pin tract infection in 10 (45.45%), and superficial wound infection in 9 (40.91%) and peaked in bimodal fashion at 4 and 8 weeks postoperatively. Radiographic analysis of the pre- versus postoperative alignment showed statistically significant changes in the lateral talo-first metatarsal angle (p = .02) and lateral talar declination angle (p = .01). The limb salvage rates with diabetic Charcot reconstruction are improving in part because of the continued development of increasingly superior modalities for both internal and external fixation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Comprehensive Review of Adipose Stem Cells and Their Implication in Distraction Osteogenesis and Bone Regeneration

    PubMed Central

    Morcos, Mina W.; Al-Jallad, Hadil; Hamdy, Reggie

    2015-01-01

    Bone is one of the most dynamic tissues in the human body that can heal following injury without leaving a scar. However, in instances of extensive bone loss, this intrinsic capacity of bone to heal may not be sufficient and external intervention becomes necessary. Several techniques are available to address this problem, including autogenous bone grafts and allografts. However, all these techniques have their own limitations. An alternative method is the technique of distraction osteogenesis, where gradual and controlled distraction of two bony segments after osteotomy leads to induction of new bone formation. Although distraction osteogenesis usually gives satisfactory results, its major limitation is the prolonged duration of time required before the external fixator is removed, which may lead to numerous complications. Numerous methods to accelerate bone formation in the context of distraction osteogenesis have been reported. A viable alternative to autogenous bone grafts for a source of osteogenic cells is mesenchymal stem cells from bone marrow. However, there are certain problems with bone marrow aspirate. Hence, scientists have investigated other sources for mesenchymal stem cells, specifically adipose tissue, which has been shown to be an excellent source of mesenchymal stem cells. In this paper, the potential use of adipose stem cells to stimulate bone formation is discussed. PMID:26448947

  7. Treatment of type II odontoid fracture with a novel technique

    PubMed Central

    Zhu, Ce; Wang, Lei; Liu, Hao; Song, Yueming; Liu, Limin; Li, Tao; Gong, Quan

    2017-01-01

    Abstract Surgical methods for type II odontoid fracture can be classified into 2 main groups: anterior or posterior approach. A more effective way to achieve bone fusion with the lowest possible surgical risk is needed. Therefore, the aim of our study was to describe and evaluate a novel technique, cable-dragged reduction/cantilever beam internal fixation for the treatment of type II odontoid fracture. This was a retrospective study enrolled 34 patients underwent posterior cable-dragged reduction/cantilever-beam internal fixation surgery. Medical records, rates of reduction, the location of the instrumentation and fracture healing during follow-up were analyzed. Once fracture healing was obtained, instrumentation was removed. Neck pain (scored using a visual analog scale [VAS]), neck stiffness, patient satisfaction, and neck disability index (NDI) were recorded before and after removing the instrumentation during follow-up. The mean duration of follow up was 22.8 ± 5.3 months. There was no iatrogenic damage to nerves or blood vessels. Radiographic evaluation showed complete reduction in the 20 patients with fracture displacement and satisfactory fracture healing in all 34 cases. Titanium cable breakage was observed in 4 patients after fracture healing. After removal of instrumentation, significant improvements were seen in neck-pain VAS score, neck stiffness, patient satisfaction, and NDI (all P < .01). Posterior cable-dragged reduction/cantilever-beam internal fixation was an optimal salvage maneuver to conventional surgical methods such as anterior screw fixation and C1–C2 screw-rod system. The operative difficulty and incidence of nerve and vascular injury were reduced. Its major disadvantage is the exposure and screw-setting at C3, which is left intact in traditional surgery, and it is suitable only for patients with intact C1 posterior arches. PMID:29095313

  8. Functional outcomes following syndesmotic fixation: A comparison of screws retained in situ versus routine removal - Is it really necessary?

    PubMed

    Tucker, Adam; Street, Julia; Kealey, David; McDonald, Sinead; Stevenson, Mike

    2013-12-01

    Syndesmotic disruption can occur in up to 20% of ankle fractures and is more common in Weber Type C injuries. Syndesmotic repair aims to restore ankle stability. Routine removal of syndesmosis screws is advocated to avoid implant breakage and adverse functional outcome such as pain and stiffness, but conflicting evidence exists to support this. The aim of the current study is to determine whether functional outcome differs in patients who had syndesmosis screws routinely removed, compared to those who did not, and whether a cost benefit exists if removal of screws is not routinely necessary. A retrospective review of consecutive syndesmosis repairs was performed from 1 January 2008 to 31 December 2010 in a single regional trauma centre. We identified 91 patients who had undergone open reduction internal fixation of an ankle fracture with placement of a syndesmosis screw at index procedure. As many as 69 patients were eligible for the study as defined by the inclusion criteria and they completed a validated functional outcome questionnaire. The functional outcomes of patients with 'retained screws' and 'removed screws' were analysed and compared using the Olerud Molander Ankle Score (OMAS). A total of 63 patients responded with a mean follow-up period of 31 months (range 10-43 months). Of those patients, 43 underwent routine screw removal whilst 20 had screws left in situ. The groups were comparable considering age, gender and follow-up time. The 'retained' group scored higher mean OMAS scores, 81.5±19.3 compared to 75±12.9 in the 'removed' group (p=0.107). The retained group achieved higher functional scores in each of the OMAS domains as well as experiencing less pain. When adjusted for gender, the findings were found to be statistically significant (p=0.046). Our study has shown that retained-screw fixation does not significantly impair functional capacity, with additional cost-effectiveness. We therefore advocate that syndesmosis screws be left in situ and should only be removed in case of symptomatic implants beyond 6 months postoperatively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Rigid fixation of facial fractures in children.

    PubMed

    Koltai, P J; Rabkin, D; Hoehn, J

    1995-01-01

    This article presents a retrospective analysis of a selective use of rigid fixation among 62 children with facial fractures, treated at a Level I trauma center over a 5-year period (1986-1991). There were 21 mandible fractures, 11 orbital fractures, 11 zygomaticomalar complex fractures, 7 nasal fractures, 5 maxillary fractures, 3 pan-facial fractures, 2 nasal-orbital-ethmoidal complex fractures, and 2 frontal sinus fractures. Only 18 children had rigid fixation of their injuries. Complications of Le Fort upper facial fractures repaired with rigid fixation involved perioperative sinusitis; one case required oral antibiotics, the other ethmoidectomy and maxillary antrostomy. One child with a Le Fort fracture had delayed exposure of a zygomaticomalar buttress plate, which required surgical removal. Permanent enophthalmos occurred in two children with Le Fort fractures. The authors conclude that traditional conservative management is appropriate in most cases. However, in children aged 13 and older with mandible fractures and children with complex mid- and upper facial fractures, a judicious use of rigid fixation has advantages over the traditional techniques.

  10. Arthroscopic Management of Tibial Spine Avulsion Fractures: Principles and Techniques.

    PubMed

    Strauss, Eric J; Kaplan, Daniel James; Weinberg, Maxwell E; Egol, Jonathan; Jazrawi, Laith M

    2018-05-15

    Tibial spine fractures are uncommon injuries affecting the insertion of the anterior cruciate ligament on the tibia. They typically occur in skeletally immature patients aged 8 to 14 years and result from hyperextension of the knee with a valgus or rotational force. Diagnosis is based on history, physical examination, and standard radiographs. The use of MRI can identify entrapped soft tissue that may prevent reduction. Open or arthroscopic repair is indicated in patients with partially displaced fractures (>5 mm) with one third to one half of the avulsed fragment elevated, in patients who have undergone unsuccessful nonsurgical reduction and long leg casting or bracing, and in patients with completely displaced fractures. Arthroscopy offers reduced invasiveness and decreased morbidity. Suture fixation and screw fixation have produced successful results. Suture fixation can eliminate the risk of fracture fragment comminution during screw insertion, the risk of neurovascular injury, and the need for hardware removal. Suture fixation is ideal in cases in which existing comminution prevents screw fixation.

  11. Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients.

    PubMed

    Anderson, Richard C E; Ragel, Brian T; Mocco, J; Bohman, Leif-Erik; Brockmeyer, Douglas L

    2007-07-01

    Atlantoaxial and occipitocervical instability in children have traditionally been treated with posterior bone and wire fusion and external halo orthoses. Recently, successful outcomes have been achieved using rigid internal fixation, particularly C1-2 transarticular screws. The authors describe flow diagrams created to help clinicians determine which method of internal fixation to use in complex anatomical circumstances when bilateral transarticular screw placement is not possible. The records of children who underwent either atlantoaxial or occipitocervical fixation with rigid internal fixation over an 11-year period were retrospectively reviewed to define flow diagrams used to determine treatment protocols. Among the 95 patients identified who underwent atlantoaxial or occipitocervical fixation, the craniocervical anatomy in 25 patients (six atlantoaxial and 19 occipitocervical fixations [26%]) required alternative methods of internal fixation. Types of screw fixation included loop or rod constructs anchored by combinations of C1-2 transarticular screws (15 constructs), C-1 lateral mass screws (11), C-2 pars screws (24), C-2 translaminar screws (one), and subaxial lateral mass screws (six). The mean age of the patients (15 boys and 10 girls) was 9.8 years (range 1.3-17 years). All 22 patients with greater than 3-month follow-up duration achieved solid bone fusion and maintained stable constructs on radiographic studies. Clinical improvement was seen in all patients who had preoperative symptoms. Novel flow diagrams are suggested to help guide selection of rigid internal fixation constructs when performing pediatric C1-2 and occipitocervical stabilizations. Use of these flow diagrams has led to successful fusion in 25 pediatric patients with difficult anatomy requiring less common constructs.

  12. Repair of Tibiotarsal Rotation in 7 Chukar Partridges (Alectoris chukar) and 12 Domestic Pigeons (Columba livia domestica) with Type-2 External Skeletal Fixator Intramedullary Pin Tie-in.

    PubMed

    Kaya, Didar Aydin; Özsoy, Serhat

    2017-09-01

    Rotational deformities of the long bones affect various avian species. Tibiotarsal rotation may cause the leg to deviate up to 180° from the dorsoplantar axis in a matter of days, thus preventing the birds from walking freely and leading to the inability to stand. In this study, tibiotarsal rotation observed in pigeons and partridges was managed by creating a closed fracture in the tibiotarsus and then, following reduction, stabilizing it with an intramedullary tie-in Type 2 external skeletal fixation system. Functional healing was achieved in 12 pigeons (Columba livia domestica; mean healing time, 38 days) and 7 partridges (Alectoris chukar; mean healing time, 40 days). This treatment was successful. In small bird species (<1 kg), this simple and inexpensive surgical intervention may provide a highly effective method for the treatment of rotational deformities.

  13. Bilateral humeral lengthening in achondroplasia with unilateral external fixators: is it safe and does it improve daily life?

    PubMed

    Balci, H I; Kocaoglu, M; Sen, C; Eralp, L; Batibay, S G; Bilsel, K

    2015-11-01

    A retrospective study was performed in 18 patients with achondroplasia, who underwent bilateral humeral lengthening between 2001 and 2013, using monorail external fixators. The mean age was ten years (six to 15) and the mean follow-up was 40 months (12 to 104). The mean disabilities of the arm, shoulder and hand (DASH) score fell from 32.3 (20 to 40) pre-operatively to 9.4 (6 to 14) post-operatively (p = 0.037). A mean lengthening of 60% (40% to 95%) was required to reach the goal of independent perineal hygiene. One patient developed early consolidation, and fractures occurred in the regenerate bone of four humeri in three patients. There were three transient radial nerve palsies. Humeral lengthening increases the independence of people with achondroplasia and is not just a cosmetic procedure. ©2015 The British Editorial Society of Bone & Joint Surgery.

  14. Pediatric and adolescent applications of the Taylor Spatial Frame.

    PubMed

    Paloski, Michael; Taylor, Benjamin C; Iobst, Christopher; Pugh, Kevin J

    2012-06-01

    Limb deformity can occur in the pediatric and adolescent populations from multiple etiologies: congenital, traumatic, posttraumatic sequelae, oncologic, and infection. Correcting these deformities is important for many reasons. Ilizarov popularized external fixation to accomplish this task. Taylor expanded on this by designing an external fixator in 1994 with 6 telescoping struts that can be sequentially manipulated to achieve multiaxial correction of deformity without the need for hinges or operative frame alterations. This frame can be used to correct deformities in children and has shown good anatomic correction with minimal morbidity. The nature of the construct and length of treatment affects psychosocial factors that the surgeon and family must be aware of prior to treatment. An understanding of applications of the Taylor Spatial Frame gives orthopedic surgeons an extra tool to correct simple and complex deformities in pediatric and adolescent patients. Copyright 2012, SLACK Incorporated.

  15. A novel simple external fixation for securing silicone stent in patients with upper tracheal stenosis

    PubMed Central

    Lin, Xiaoxiao; Ye, Min; Li, Yuping

    2018-01-01

    Upper tracheal stenosis is considered as a potentially life-threatening condition. Silicone stenting is an attractive treatment option for patients with upper tracheal stenosis. However, its use has been compromised by a major complication, stent migration. In the report, we introduced a novel external fixation of silicone stent which only needed one puncture site and involved a silicon chip as an anchoring device. All equipment and materials including the silicon chip were available in routine bronchoscopy suite. The method had been successfully performed in three patients with upper tracheal stenosis at our institution. And the patients were monitored for over 20 months after the intervention, and no spontaneous stent migration occurred. Therefore, we believe this is a simple and reliable approach for improving the outcome of silicone stenting in patients with upper tracheal stenosis and should be introduced in clinical practice.

  16. Management of severe open ankle-foot trauma by a simple external fixation technique: an alternative during war and in resource-poor and low-technology environments.

    PubMed

    Pedrini, Gianpaolo; Cardi, Maurizio; Landini, Alberto; Strada, Gino

    2011-03-01

    Severe open foot and ankle injuries are still a challenge for the orthopaedic surgeon. Their treatment is even more difficult in third world countries and in war settings where high-energy trauma with severe soft tissue damage is more frequent. Lack of equipment, poor resources and hygiene, and different cultural systems make most of the standard proposed treatments difficult to apply. The authors describe an inexpensive, rapid, minimally invasive, and easy-to-apply external fixation technique for the treatment of severe open ankle-foot fractures. With the main goal of soft tissue management rather than definitive treatment of any bony injuries, this technique was developed over time during many consecutive missions in Sierra Leone and Afghanistan as an alternative to more appropriate treatments with surprisingly satisfactory short- and long-term results.

  17. Open tibial fractures grade IIIC treated successfully with external fixation, negative-pressure wound therapy and recombinant human bone morphogenetic protein 7.

    PubMed

    Babiak, Ireneusz

    2014-10-01

    The aim of the therapy in open tibial fractures grade III was to cover the bone with soft tissue and achieve healed fracture without persistent infection. Open tibial fractures grade IIIC with massive soft tissue damage require combined orthopaedic, vascular and plastic-reconstructive procedures. Negative-pressure wound therapy (NPWT), used in two consecutive cases with open fracture grade IIIC of the tibia diaphysis, healed extensive soft tissue defect with exposure of the bone. NPWT eventually allowed for wound closure by split skin graft within 21-25 days. Ilizarov external fixator combined with application of recombinant human bone morphogenetic protein-7 at the site of delayed union enhanced definitive bone healing within 16-18 months. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  18. Temporary Segmental Distraction in a Dog with Degenerative Lumbosacral Stenosis.

    PubMed

    Willems, Nicole; Kersten, Roel F M R; van Gaalen, Steven M; Öner, F Cumhur; Strijkers, Gustav J; Veraa, Stefanie; Beukers, Martijn; Tryfonidou, Marianna A; Meij, Björn P

    2018-06-02

     Degenerative lumbosacral stenosis (DLSS) is characterized by intervertebral disc degeneration and causes lower back pain in dogs. Temporary distraction in rabbit models with induced intervertebral disc degeneration showed signs of intervertebral disc repair. In the present study, we assessed safety and efficacy of temporary segmental distraction in a dog with clinical signs of DLSS.  Distraction of the lumbosacral junction by pedicle screw-rod fixation was applied in a 5-year-old Greyhound with DLSS and evaluated by radiography, magnetic resonance imaging, and force plate analysis before and after distraction.  Safe distraction of the lumbosacral junction was demonstrated, with improvement of clinical signs after removal of the distraction device. Signal intensity of the intervertebral disc showed no changes over time. T2 value was highest directly after removal of the distraction device but decreased by 10% of the preoperative value at 9 months of follow-up. Disc height decreased (8%) immediately after removal of the distraction device, but recovered to the initial value. A decrease in the pelvic/thoracic propulsive force during pedicle screw-rod fixation and distraction was demonstrated, which slowly increased by 4% compared with the initial value.  Temporary pedicle screw-rod fixation in combination with distraction in a dog with DLSS was safe, improved clinical signs and retained disc height at 9 months of follow-up. Schattauer GmbH Stuttgart.

  19. The Use of 3D Printing Technology in the Ilizarov Method Treatment: Pilot Study.

    PubMed

    Burzyńska, Karolina; Morasiewicz, Piotr; Filipiak, Jarosław

    2016-01-01

    Significant developments in additive manufacturing technology have occurred in recent years. 3D printing techniques can also be helpful in the Ilizarov method treatment. The aim of this study was to evaluate the usefulness of 3D printing technology in the Ilizarov method treatment. Physical models of bones used to plan the spatial design of Ilizarov external fixator were manufactured by FDM (Fused Deposition Modeling) spatial printing technology. Bone models were made of poly(L-lactide) (PLA). Printed 3D models of both lower leg bones allow doctors to prepare in advance for the Ilizarov method treatment: detailed consideration of the spatial configuration of the external fixation, experimental assembly of the Ilizarov external fixator onto the physical models of bones prior to surgery, planning individual osteotomy level and Kirschner wires introduction sites. Printed 3D bone models allow for accurate preparation of the Ilizarov apparatus spatially matched to the size of the bones and prospective bone distortion. Employment of the printed 3D models of bone will enable a more precise design of the apparatus, which is especially useful in multiplanar distortion and in the treatment of axis distortion and limb length discrepancy in young children. In the course of planning the use of physical models manufactured with additive technology, attention should be paid to certain technical aspects of model printing that have an impact on the accuracy of mapping of the geometry and physical properties of the model. 3D printing technique is very useful in 3D planning of the Ilizarov method treatment.

  20. Outcomes following femoral lengthening: An initial comparison of the Precice intramedullary lengthening nail and the LRS external fixator monorail system.

    PubMed

    Laubscher, M; Mitchell, C; Timms, A; Goodier, D; Calder, P

    2016-10-01

    Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages. We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared. In 20 cases (15 patients) the Precice lengthening nail was used and in 13 cases (seven patients) the LRS external fixator system. The desired length was achieved in all cases in the Precice group and in 12 of 13 cases in the LRS group. The mean healing index was 31.3 days/cm in the Precice and 47.1 days/cm in the LRS group (p < 0.001). This was associated with an earlier ability to bear full weight without aids in the Precice group. There were more complications with LRS lengthening, including pin site infections and regenerate deformity. Implant tolerance and the patients' perception of the cosmetic result were better with the Precice treatment. Femoral lengthening with the Precice femoral nail achieved excellent functional results with fewer complications and greater patient satisfaction when compared with the LRS system in our patients. Cite this article: Bone Joint J 2016;98-B:1382-8. ©2016 The British Editorial Society of Bone & Joint Surgery.

  1. Fixation of the stressed state of glass plates by coating them with thin films using a plasma focus installation

    NASA Astrophysics Data System (ADS)

    Kolokoltsev, V. N.; Degtiarev, V. F.; Borovitskaya, I. V.; Nikulin, V. Ya.; Peregudova, E. N.; Silin, P. V.; Eriskin, A. A.

    2018-01-01

    Elastic deformation in transparent mediums is usually studied by the photoelasticity method. For opaque mediums the method of film coating and strain gauge method are used. After the external load was removed, the interference pattern corresponding to elastic deformation of the material disappears. It is found that the elastic deformation state of the thin glass plate under the action of concentrated load can be fixed during the deposition of a thin metal film. Deposition of thin copper films was carried out by passing of plasma through the copper tube installed inside the Plasma Focus installation. After removing of the load, interference pattern on the glass plates was observed in the form of Newton’s rings and isogers in non-monochromatic light on the CCD scanners which uses uorescent lamps with cold cathode. It is supposed that the copper film fixes the relief of the surface of the glass plate at the time of deformation and saves it when the load is removed. In the case of a concentrated load, this relief has the shape of a thin lens of large radius. For this reason, the interference of coherent light rays in a thin air gap between the glass of the scanners atbed and the lens surface has the shape of Newton's rings. In this case, when scanning the back side of the plate, isogyres are observed. The presented method can be used in the analysis of the mechanical stress in a various optical elements.

  2. Temporary short-segment pedicle screw fixation for thoracolumbar burst fractures: comparative study with or without vertebroplasty.

    PubMed

    Aono, Hiroyuki; Ishii, Keisuke; Tobimatsu, Hidekazu; Nagamoto, Yukitaka; Takenaka, Shota; Furuya, Masayuki; Chiaki, Horii; Iwasaki, Motoki

    2017-08-01

    Short-segment posterior spinal instrumentation for thoracolumbar burst fracture provides superior correction of kyphosis by an indirect reduction technique, but it has a high failure rate. The purpose of the study we report here was to compare outcomes for temporary short-segment pedicle screw fixation with vertebroplasty and for such fixation without vertebroplasty. This is a prospective multicenter comparative study. We studied 62 consecutive patients with thoracolumbar burst fracture who underwent short-segment posterior instrumentation using ligamentotaxis with Schanz screws with or without vertebroplasty. Radiological parameters (Cobb angle on standing lateral radiographs) were used. Implants were removed approximately 1 year after surgery. Neurologic function, kyphotic deformity, canal compromise, and fracture severity were evaluated prospectively. After surgery, all patients with neurologic deficit had improvement equivalent to at least one grade on the American Spinal Injury Association impairment scale and had fracture union. Kyphotic deformity was reduced significantly, and reduction of the vertebrae was maintained with and without vertebroplasty, regardless of load-sharing classification. Although no patient required additional anterior reconstruction, kyphotic change was observed at disc level mainly after implant removal with or without vertebroplasty. Temporary short-segment fixation yielded satisfactory results in the reduction and maintenance of fractured vertebrae with or without vertebroplasty. Kyphosis recurrence may be inevitable because adjacent discs can be injured during the original trauma. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Joint distraction and movement for repair of articular cartilage in a rabbit model with subsequent weight-bearing.

    PubMed

    Nishino, T; Chang, F; Ishii, T; Yanai, T; Mishima, H; Ochiai, N

    2010-07-01

    We have previously shown that joint distraction and movement with a hinged external fixation device for 12 weeks was useful for repairing a large articular cartilage defect in a rabbit model. We have now investigated the results after six months and one year. The device was applied to 16 rabbits who underwent resection of the articular cartilage and subchondral bone from the entire tibial plateau. In group A (nine rabbits) the device was applied for six months. In group B (seven rabbits) it was in place for six months, after which it was removed and the animals were allowed to move freely for an additional six months. The cartilage remained sound in all rabbits. The areas of type II collagen-positive staining and repaired soft tissue were larger in group B than in group A. These findings provide evidence of long-term persistence of repaired cartilage with this technique and that weight-bearing has a positive effect on the quality of the cartilage.

  4. PECTUS CARINATUM: A NOVEL METHOD OF STERNAL FIXATION.

    PubMed

    Taha, Assad; Sfeir, Pierre; Al-Taki, Muhyeddine

    2016-01-01

    The traditional method for fixing the sternum during surgical repair of pectus carinatum is through the use of a stainless steel bar (Adkin’s strut). In this article we describe a new method of sternal fixation using nonabsorbable sutures which are placed in a transverse and crossed fashion anterior to the sternum. This method provides stable sternal fixation and spares the patient a second operation to remove the steel bar. The absence of metallic implants allows clearer view of the thoracic structures in future X-rays, CT scans and MRI, and is likely to be more acceptable to patients than the implantation of a metallic strut in their chest. In addition, it is less costly.

  5. A prospective study of external stenting of saphenous vein grafts to the right coronary artery: the VEST II study.

    PubMed

    Taggart, David P; Amin, Sanaz; Djordjevic, Jasmina; Oikonomou, Evangelos K; Thomas, Sheena; Kampoli, Anna-Maria; Sabharwal, Nikant; Antoniades, Charalambos; Krasopoulos, George

    2017-05-01

    External stents significantly reduce intimal hyperplasia and improve lumen uniformity and flow pattern in saphenous vein grafts (SVG) 1 year after coronary artery bypass grafting. However, recent studies have shown that at 1 year there is a lower patency of externally stented SVG to the right coronary artery (RCA) (55-60%) when compared to the left sided coronary arteries (85-90%). In the current study, we investigated whether avoidance of both fixation of the external stent to the anastomoses and the use of metal clips to ligate SVG side branches would improve the early patency of externally stented SVG to the RCA. Thirty patients received a SVG to the right territory supported with an external stent. Graft patency was confirmed at the end of surgery in all patients. The primary endpoint was SVG patency assessed by computed tomography angiography (CTA) at 3-6 months. Graft failure was defined as > 50% stenosis. Twenty-nine patients (96.6%) completed the follow up period and CT angiography data was available for a total of 43 SVGs, (29 supported and 14 unsupported SVGs) and 47 arterial grafts. Patency of stented SVGs was 86.2% (25/29 on CTA). All non-stented SVGs to the left territory were patent. Patency rates of the left internal mammary arteries and right internal mammary arteries grafts were 96.6% and 83.3%, respectively. Avoidance of both metallic clips to ligate side branches and of fixation of venous external support trial (VEST) stents to the anastomoses mark a significant improvement in patency of stented SVG to the right coronary territory. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Distribution and rates of nitrogen fixation in the western tropical South Pacific Ocean constrained by nitrogen isotope budgets

    NASA Astrophysics Data System (ADS)

    Knapp, Angela N.; McCabe, Kelly M.; Grosso, Olivier; Leblond, Nathalie; Moutin, Thierry; Bonnet, Sophie

    2018-05-01

    Constraining the rates and spatial distribution of dinitrogen (N2) fixation fluxes to the ocean informs our understanding of the environmental sensitivities of N2 fixation as well as the timescale over which the fluxes of nitrogen (N) to and from the ocean may respond to each other. Here we quantify rates of N2 fixation as well as its contribution to export production along a zonal transect in the western tropical South Pacific (WTSP) Ocean using N isotope (δ15N) budgets. Comparing measurements of water column nitrate + nitrite δ15N with the δ15N of sinking particulate N at a western, central, and eastern station, these δ15N budgets indicate high, modest, and low rates of N2 fixation at the respective stations. The results also imply that N2 fixation supports exceptionally high, i.e. ≥ 50 %, of export production at the western and central stations, which are also proximal to the largest iron sources. These geochemically based rates of N2 fixation are equal to or greater than those previously reported in the tropical North Atlantic, indicating that the WTSP Ocean has the capacity to support globally significant rates of N2 fixation, which may compensate for N removal in the oxygen-deficient zones of the eastern tropical Pacific.

  7. Dorsal or Volar Plate Fixation of the Distal Radius: Does the Complication Rate Help Us to Choose?

    PubMed

    Disseldorp, D J G; Hannemann, P F W; Poeze, M; Brink, P R G

    2016-08-01

    Internal fixation with plates is a reliable fixation technique for the treatment of distal radius fractures. An ongoing discussion exists whether volar or dorsal plating is the appropriate technique. In clinical practice, volar plate fixation is usually preferred because of the assumed lower complication frequency. However, recent studies with the newer generation low-profile dorsal plates reported lower complication rates. The aim of our study was to evaluate the differences in complication rates between volar and dorsal plate for the treatment of distal radius fractures in adult patients. A total of 214 patients with acute distal radius fractures were included in this retrospective study with a minimum 2 years of follow-up. In total, 123 patients were treated with dorsal plate fixation and 91 patients with volar plate fixation. Our primary study outcome was complication rate. The overall risk for complications was 15.4% in the dorsal group and 14.3% in the volar group (p = 0.81). A total of 19 patients had implant removal due to complications: 11 patients in the dorsal group and 8 patients in the volar group (p = 0.97). There is no preferred plate fixation technique based on these study results. In our opinion, decision for type of plate fixation should be based on fracture type and surgeon's experience with the specific approach and plate types. Therapeutic level III.

  8. Nitrogen fixation on early Mars and other terrestrial planets: experimental demonstration of abiotic fixation reactions to nitrite and nitrate.

    PubMed

    Summers, David P; Khare, Bishun

    2007-04-01

    Understanding the abiotic fixation of nitrogen is critical to understanding planetary evolution and the potential origin of life on terrestrial planets. Nitrogen, an essential biochemical element, is certainly necessary for life as we know it to arise. The loss of atmospheric nitrogen can result in an incapacity to sustain liquid water and impact planetary habitability and hydrological processes that shape the surface. However, our current understanding of how such fixation may occur is almost entirely theoretical. This work experimentally examines the chemistry, in both gas and aqueous phases, that would occur from the formation of NO and CO by the shock heating of a model carbon dioxide/nitrogen atmosphere such as is currently thought to exist on early terrestrial planets. The results show that two pathways exist for the abiotic fixation of nitrogen from the atmosphere into the crust: one via HNO and another via NO(2). Fixation via HNO, which requires liquid water, could represent fixation on a planet with liquid water (and hence would also be a source of nitrogen for the origin of life). The pathway via NO(2) does not require liquid water and shows that fixation could occur even when liquid water has been lost from a planet's surface (for example, continuing to remove nitrogen through NO(2) reaction with ice, adsorbed water, etc.).

  9. Fixation of osteochondral fractures in rabbit knees. A comparison of Kirschner wires, fibrin sealant, and polydioxanone pins.

    PubMed

    Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M

    1992-03-01

    We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.

  10. Intra-articular fractures of the distal tibia

    PubMed Central

    Sitnik, Alexandre; Beletsky, Aleksander; Schelkun, Steven

    2017-01-01

    Results of the treatment of intra-articular fractures of the distal tibia have improved significantly during the last two decades. Recognition of the role of soft tissues has led to the development of a staged treatment strategy. At the first stage, joint-bridging external fixation and fibular fixation are performed. This leads to partial reduction of the distal tibial fracture and allows time for the healing of soft tissues and detailed surgical planning. Definitive open reduction and internal fixation of the tibial fracture is performed at a second stage, when the condition of the soft tissues is safe. The preferred surgical approach(es) is chosen based on the fracture morphology as determined from standard radiographic views and computed tomography. Meticulous atraumatic soft-tissue handling and the use of modern fixation techniques for the metaphyseal component such as minimally invasive plate osteosynthesis further facilitate healing. Cite this article: EFORT Open Rev 2017;2:352-361. DOI: 10.1302/2058-5241.2.150047 PMID:28932487

  11. Management of recent unstable fractures of the pelvic ring. An update conference supported by the Club Bassin Cotyle. (Pelvis-Acetabulum Club).

    PubMed

    Tonetti, J

    2013-02-01

    Traumatic injury to the pelvic ring is a result of high energy trauma in young patients. These osteo-ligamentous injuries are associated with numerous lesions including retroperitoneal hematoma, urogenital, cutaneous and neurological (lumbosacral plexus). The goal of initial management is to restore vital indicators, urinary excretion function and protect the patient from infectious complications. An emergency decisional algorithm helps manage haemodynamic instability. Initial bone and ligament procedures should reduce displacement and make it possible for the patient the wait until his condition is stable enough for definitive surgical fixation. The goal of surgical treatment is to avoid nonunion and malunion. Stable fixation of the posterior arch after reduction favors union. Different techniques can be used by the posterior, anterior ilio-inguinal or lateral percutaneous approaches. Anterior fixation is discussed to improve reduction and increase the stability obtained with a posterior procedure. Anterior external fixation is useful to temporarily reinforce posterior stabilization. Copyright © 2013. Published by Elsevier Masson SAS.

  12. Short-term outcomes of arthroscopic TightRope® fixation are better than hook plate fixation in acute unstable acromioclavicular joint dislocations.

    PubMed

    Bin Abd Razak, Hamid Rahmatullah; Yeo, Eng-Meng Nicholas; Yeo, William; Lie, Tijauw-Tjoen Denny

    2018-07-01

    The aim of this study was to compare the short-term outcomes of arthroscopic TightRope ® fixation with that of hook plate fixation in patients with acute unstable acromioclavicular joint dislocations. We conducted a prospective case-control study of twenty-six patients with an acute ACJ dislocation who underwent surgical repair with either an arthroscopic TightRope ® fixation or a hook plate from 2013 to 2016. Clinical and radiological data were collected prospectively. Clinical outcomes were evaluated using the Constant Score, the University of California at Los Angeles (UCLA) Shoulder Score, Oxford Shoulder Score as well as the visual analogue scale. Radiological outcomes were assessed with the coracoclavicular distance (CCD). Sixteen patients underwent arthroscopic TightRope ® fixation, while 10 patients underwent hook plate fixation. There were no significant differences in the preoperative variables except for the mean UCLA 4b infraspinatus score (TightRope ® 2.8 vs. hook plate 3.8; p = 0.030). Duration of surgery was significantly longer in the TightRope ® group. At 1 year post-operatively, the TightRope ® group had a significantly better Constant Score and CCD with no complications. All patients with hook plate fixation had to undergo a second procedure for removal of implant, and 3 patients had complications. Arthroscopic TightRope ® fixation is a good option for the treatment of acute unstable ACJ dislocations. It has better short-term clinical and radiological outcomes as well as lesser complications when compared to hook plate fixation. Therapeutic, Level III.

  13. Maxillomandibular Fixation by Plastic Surgeons: Cost Analysis and Utilization of Resources.

    PubMed

    Farber, Scott J; Snyder-Warwick, Alison K; Skolnick, Gary B; Woo, Albert S; Patel, Kamlesh B

    2016-09-01

    Maxillomandibular fixation (MMF) can be performed using various techniques. Two common approaches used are arch bars and bone screws. Arch bars are the gold standard and inexpensive, but often require increased procedure time. Bone screws with wire fixation is a popular alternative, but more expensive than arch bars. The differences in costs of care, complications, and operative times between these 2 techniques are analyzed. A chart review was conducted on patients treated over the last 12 years at our institution. Forty-four patients with CPT code 21453 (closed reduction of mandible fracture with interdental fixation) with an isolated mandible fracture were used in our data collection. The operating room (OR) costs, procedure duration, and complications for these patients were analyzed. Operative times were significantly shorter for patients treated with bone screws (P < 0.002). The costs for one trip to the OR for either method of fixation did not show any significant differences (P < 0.840). More patients with arch bar fixation (62%) required a second trip to the OR for removal in comparison to those with screw fixation (31%) (P < 0.068). This additional trip to the OR added significant cost. There were no differences in patient complications between these 2 fixation techniques. The MMF with bone screws represents an attractive alternative to fixation with arch bars in appropriate scenarios. Screw fixation offers reduced costs, fewer trips to the OR, and decreased operative duration without a difference in complications. Cost savings were noted most significantly in a decreased need for secondary procedures in patients who were treated with MMF screws. Screw fixation offers potential for reducing the costs of care in treating patients with minimally displaced or favorable mandible fractures.

  14. Global metabolic rewiring for improved CO2 fixation and chemical production in cyanobacteria.

    PubMed

    Kanno, Masahiro; Carroll, Austin L; Atsumi, Shota

    2017-03-13

    Cyanobacteria have attracted much attention as hosts to recycle CO 2 into valuable chemicals. Although cyanobacteria have been engineered to produce various compounds, production efficiencies are too low for commercialization. Here we engineer the carbon metabolism of Synechococcus elongatus PCC 7942 to improve glucose utilization, enhance CO 2 fixation and increase chemical production. We introduce modifications in glycolytic pathways and the Calvin Benson cycle to increase carbon flux and redirect it towards carbon fixation. The engineered strain efficiently uses both CO 2 and glucose, and produces 12.6 g l -1 of 2,3-butanediol with a rate of 1.1 g l -1  d -1 under continuous light conditions. Removal of native regulation enables carbon fixation and 2,3-butanediol production in the absence of light. This represents a significant step towards industrial viability and an excellent example of carbon metabolism plasticity.

  15. Global metabolic rewiring for improved CO2 fixation and chemical production in cyanobacteria

    NASA Astrophysics Data System (ADS)

    Kanno, Masahiro; Carroll, Austin L.; Atsumi, Shota

    2017-03-01

    Cyanobacteria have attracted much attention as hosts to recycle CO2 into valuable chemicals. Although cyanobacteria have been engineered to produce various compounds, production efficiencies are too low for commercialization. Here we engineer the carbon metabolism of Synechococcus elongatus PCC 7942 to improve glucose utilization, enhance CO2 fixation and increase chemical production. We introduce modifications in glycolytic pathways and the Calvin Benson cycle to increase carbon flux and redirect it towards carbon fixation. The engineered strain efficiently uses both CO2 and glucose, and produces 12.6 g l-1 of 2,3-butanediol with a rate of 1.1 g l-1 d-1 under continuous light conditions. Removal of native regulation enables carbon fixation and 2,3-butanediol production in the absence of light. This represents a significant step towards industrial viability and an excellent example of carbon metabolism plasticity.

  16. Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures.

    PubMed

    Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed

    2015-09-01

    This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3-12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and 12 months postoperatively. Radiographs were done at 1 week, 3 months, and 12 months postoperatively to observe any displacement and fracture healing. All fractures healed both clinically and radiologically. No serious complications were reported in the patients. Normal occlusion was achieved in all cases. Biodegradable osteofixation of mandibular fractures offers a valuable clinical solution for pediatric patients getting the benefit of avoiding secondary surgery to remove plates, decreasing the hospital stay, further painful procedures, and psychological impact.

  17. Extraocular surgery for implantation of an active subretinal visual prosthesis with external connections: feasibility and outcome in seven patients.

    PubMed

    Besch, D; Sachs, H; Szurman, P; Gülicher, D; Wilke, R; Reinert, S; Zrenner, E; Bartz-Schmidt, K U; Gekeler, F

    2008-10-01

    Due to low energy levels in microphotodiode-based subretinal visual prostheses, an external power supply is mandatory. We report on the surgical feasibility and the functional outcome of the extraocular part of an approach to connect a subretinal prosthesis to an extracorporeal connector in the retro-auricular space via a trans-scleral, transchoroidal cable. Seven volunteers with retinitis pigmentosa received an active subretinal implant; energy was supplied by gold wires on a trans-sclerally, transchoroidally implanted polyimide foil leading to the lateral orbital rim where it was fixated and connected to a silicone cable. The cable was implanted subperiostally beneath the temporal muscle using a trocar to the retro-auricular space where it penetrated the skin for connection to a stimulator. To avoid subretinal movement of the implant, three tension relief points have been introduced. All implantations were performed as planned without complications, and no serious adverse events occurred in the postoperative period. Fixation of the implants was stable throughout the entire study duration of 4 weeks; permanent skin penetration proved to be uncomplicated. Motility was minimally restricted in downgaze and ab-/adduction. Explantation was uneventful. The above-described procedure provides a method for stable fixation of a subretinal device with a trans-scleral, transchoroidal cable connection to an extracorporeal connector.

  18. Deliberate real-time mood regulation in adulthood: the importance of age, fixation and attentional functioning.

    PubMed

    Noh, Soo Rim; Lohani, Monika; Isaacowitz, Derek M

    2011-09-01

    While previous research has linked executive attention to emotion regulation, the current study investigated the role of attentional alerting (i.e., efficient use of external warning cues) on younger (N=39) and older (N=44) adults' use of gaze to regulate their mood in real time. Participants viewed highly arousing unpleasant images while reporting their mood and were instructed to deliberately manage how they felt and to minimise the effect of those stimuli on their mood. Fixations toward the most negative areas of the images were recorded with eye tracking. We examined whether looking less at the most negative regions, compared to each individual's own tendency, was a beneficial mood regulatory strategy and how it interacted with age and alerting ability. High alerting older adults, who rely more on external cues to guide their attention, experienced a smaller decline in mood over time by activating a less-negative-looking approach (compared to their own average tendency), effectively looking away from the most negative areas of the images. More negative gaze patterns predicted better mood for younger adults, though this effect decreased over time. Alerting did not moderate gaze-mood links in younger adults. Successful mood regulation may thus depend on particular combinations of age, fixation, and attention.

  19. Deliberate Real-time Mood Regulation in Adulthood: The Importance of Age, Fixation and Attentional Functioning

    PubMed Central

    Noh, Soo Rim; Lohani, Monika; Isaacowitz, Derek M.

    2011-01-01

    While previous research has linked executive attention to emotion regulation, the current study investigated the role of attentional alerting (i.e., efficient use of external warning cues) on younger (N = 39) and older (N = 44) adults’ use of gaze to regulate their mood in real time. Participants viewed highly arousing unpleasant images while reporting their mood and were instructed to deliberately manage how they felt and to minimize the effect of those stimuli on their mood. Fixations toward the most negative areas of the images were recorded with eye tracking. We examined whether looking less at the most negative regions, compared to each individual’s own tendency, was a beneficial mood regulatory strategy and how it interacted with age and alerting ability. High alerting older adults, who rely more on external cues to guide their attention, experienced a smaller decline in mood over time by activating a less-negative-looking approach (compared to their own average tendency), effectively looking away from the most negative areas of the images. More negative gaze patterns predicted better mood for younger adults, though this effect decreased over time. Alerting did not moderate gaze-mood links in younger adults. Successful mood regulation may thus depend on particular combinations of age, fixation, and attention. PMID:21432641

  20. Open unstable metaphyseo-diaphyseal fractures of the tibia in adolescents: treatment by flexible intramedullary nails augmented by external fixator.

    PubMed

    Atef, Ashraf; El Tantawy, Ahmad

    2015-05-01

    The treatment of open and unstable metaphyseo-diaphyseal fractures of the tibia in adolescents is challenging. It is important to choose a fixation method that can maintain alignment, allow wound care and not violate the growth plate. The aim of this work was to evaluate the efficacy of using flexible intramedullary nails (FIN) augmented by external fixator (EF) in the management of such fractures. A total of 26 males, with a mean age of 14.08 years and average body weight of 49.8 kg, presented with open metaphyseo-diaphyseal tibial fractures. All cases were treated using FIN augmented by mono-lateral EF. The fractures were located at the upper third in 17 cases and at the lower third in nine cases. The fracture pattern was spiral in eight cases, oblique in seven and multi-fragmentary in 11. The results were evaluated according to the scoring system for femoral TENs. All fractures united primarily after an average eight to 12 weeks with no evident angular deformity or limb-length discrepancy. None of the cases required cast immobilization or revision procedure. Twenty patients had excellent results, six patients showed good results and none had poor results. Fracture characteristics as well as patients' characteristics had no statistically significant effect (p > 0.005) on the final end results. The use of FIN augmented by EF is a good alternative in the management of open metaphyseo-diaphyseal tibial fractures in adolescents. This fixation provides more stability, allows easy access to the wound and early patients' ambulation.

  1. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

    PubMed

    Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien

    2011-09-01

    The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

  2. The use of circular external fixators in the management of lower limb trauma in Dublin: a single surgeon's 20-year experience.

    PubMed

    O'Neill, B J; Fox, C M; Molloy, A P; O'hEireamhoin, S; Moore, D P

    2016-02-01

    It has been estimated that approximately 520,000 injury presentations are made to Irish accident and emergency departments each year. Fractures account for 20 % of these injuries. Circular external fixators (frames) have been shown to be a safe and effective method of treatment for long bone fractures where internal fixation is impossible or in-advisable. We present the outcomes of all frames applied at our institution for stabilisation of acute fractures over a 20-year period. We retrospectively reviewed a prospectively compiled database of all frames applied in our institution and identified all frames which were applied for acute lower limb trauma. We identified 68 fractures in 63 patients. There were 11 femoral fractures and 57 tibial fractures. All fractures were classified using the AO Classification system, and most fractures were Type C fractures. We used an Ilizarov frame for 53 fractures and a Taylor Spatial Frame for 15 fractures. The mean time in frame was 365 days for a femoral fracture and 230 days for a tibial fracture. There were five tibial non-unions giving an overall union rate of 93 %. Factors associated with non-union included high-energy trauma and cigarette smoking. The vast majority of lower limb fractures can be treated using 'conventional' methods. Complex fractures which are not amenable to open reduction and internal fixation or cast immobilisation can be treated in a frame with excellent results. The paucity of published reports regarding the use of frames for complex trauma reflects the under-utilisation of the technique.

  3. Arthroscopic anterior cruciate ligament reconstruction using the double press- fit technique: an alternative to interference screw fixation.

    PubMed

    Halder, Andreas M; Ludwig, Silke; Neumann, Wolfram

    2002-01-01

    Patellar tendon autograft fixation in arthroscopic anterior cruciate ligament reconstruction is commonly accomplished using interference screws. However, improper insertion of the screws may reduce primary stability, injure the posterior femoral cortex, or displace hardware into the joint. Even if placed properly, metallic screws interfere with postoperative magnetic resonance imaging. In case of revision surgery, removing screws may be difficult and leaves bone defects. Retrospective study. An arthroscopic technique was developed that achieves patellar tendon autograft fixation by press-fit without any supplemental internal fixation. Forty patients were examined clinically and by KT-1000 arthrometer 28.7 months (range, 22 to 40 months) postoperatively. The mean difference in side-to-side laxity was 1.3 mm (SD 2.2) and the results according to the IKDC score were as follows: 7 A, 28 B, 5 C, and 0 D. The double press-fit technique we present avoids all complications related to the use of interference screws and creates an ideal environment for osseous integration of the bone-patellar tendon-bone autograft. Concurrently, it achieves a stable fixation of the autograft and allows early functional rehabilitation. However, fixation strength depends on bone quality and the arthroscopic procedure is demanding.

  4. Treatment of hardware infection after osteosynthesis of lower leg using negative pressure wound therapy and transforming powder dressing.

    PubMed

    Marinović, Marin; Ivandcić, Aldo; Spanjol, Josip; Pina, Maja; Bakota, Bore; Bandalović, Ante; Cukeljs, Fabijan

    2014-12-01

    Fractures of the distal part of the lower leg are more common in everyday practice and traumatology. In young and active patients these injuries are mainly caused by high energy trauma. They are treated with external fixator in first step, and in second step, after sanation of the soft tissue, with open reduction and internal fixation (ORIF). It is very safe and effective method of treatment. Treatment of the infections that occur in the early postoperative period after open reduction and internal fixation represents a great problem and challenge for surgeons. It is widely accepted that the presence of deep infection can't be cured in the presence of hardware. However, removal of hardware in the presence of unhealed fractures significantly complicates sanation of infection and fracture itself We have decided to present a 35-years-old patient with a hardware infection with present chronic wound with hardware exposed eight months after the first operation and six months after second operation. The wound measured one centimeter in diameter with cell detritus and bad granulations tissue inside the wound. Hardwre was exposed in the depth of the wound.The secretion was minimal. Negative Pressure Wound Therapy (NPWT) was applicated after debridemet and lavage performed in ambulatory conditions. The starting therapy was continuously -125 mm Hg of vacuum. After five days of NPWT the defect was partially filled with granula- tion tissue. For another five days we continue with NPWT with the same values of-125 mm Hg pressure but in the inter- mitent mode. After that period we used transforming powder dressing for covering and protection of the wound with was filled with granulation tissue. Five days later, wound was completely healed with epithelisation. After four months of patient follow-up, we found the wound is completely repaired. The patient denies pain and has continued orderly flow of fracture healing, with no signs of infection.

  5. The use of small (2.7 mm) screws for arthroscopically guided repair of carpal chip fractures.

    PubMed

    Wright, I M; Smith, M R W

    2011-05-01

    Removal of large chip fractures of the carpal bones and the osteochondral deficits that result, have been associated with a worse prognosis than removal of small fragments in similar locations. Reducing the articular defects by repair of large osteochondral fragments may have advantages over removal. Horses with osteochondral chip fractures that were of sufficient size and infrastructure to be repaired with small (2.7 mm diameter) AO/ASIF cortex screws were identified and repair effected by arthroscopically guided internal fixation. Thirty-three horses underwent surgery to repair 35 fractures of the dorsodistal radial carpal bone (n = 25), the dorsal margin of the radial facet of the third carpal bone (n = 9) and the intermediate facet of the distal radius (n = 1). There were no surgical complications and fractures healed satisfactorily in 26 of 28 horses and 23 horses returned to racing performance. Arthroscopically guided repair of carpal chip fractures with small diameter cortex screws is technically feasible and experiences with 33 cases suggest that this may have advantages over fragment removal in managing such cases. Surgeons treating horses with large chip fractures of the carpal bones should consider arthroscopically guided internal fixation as an alternative to removal. © 2010 EVJ Ltd.

  6. Interrami intraoral fixation technique for severe mandibular rifle fragmented bullet injury management.

    PubMed

    Shuker, Sabri T

    2013-07-01

    Interrami intraoral Kirschner wire fixation technique is presented for the reduction, stabilization, and immobilization of a pulverized and avulsed lower jaw caused by rifle fragmented bullet injuries. This indirect mandibular war injury fixation technique was tolerated by the patients and tissue more than any indirect external fixation. In addition, it is easier than open reduction using large bone plates for disrupted ballistics mandibular injury defects. An interrami intraoral fixation is appropriate for severely disrupted mandibular hard and soft tissues, and has been adapted in cases of mass casualties and limited resources. Benefits of use include limited hospital beds and fewer follow-up visits. Rifle fragmented bullet injuries need more attention for several reasons: not only because of the higher mortality and devastating nature of the injuries, but also because these injuries are responsible for an unreported type of bullet biomechanism wounding in the craniofacial region. In turn, this necessitates specialized victim management. The survival rates depend on immediate proper execution of airway, breathing, and circulation, which become more complicated as it relates to airway compromise and oropharyngeal hemorrhage resuscitation. Survival is predicated on the implementation of feasible, sensible, life-saving techniques that are applied at the appropriate time.

  7. Novel fabrication method of the peritoneal dialysis filter using silk fibroin with urease fixation system.

    PubMed

    Moon, Bo Mi; Choi, Myung-Jin; Sultan, Md Tipu; Yang, Jae Won; Ju, Hyung Woo; Lee, Jung Min; Park, Hyun Jung; Park, Ye Ri; Kim, Soo Hyeon; Kim, Dong Wook; Lee, Min Chae; Jeong, Ju Yeon; Lee, Ok Joo; Sung, Gun Yong; Park, Chan Hum

    2017-10-01

    During the last decade, there has been a great advance in the kidney dialysis system by wearable artificial kidney (WAK) system for end-stage renal disease patients. Uremic solute removal and water regeneration system are the most prerequisite for WAK to work properly. In this study, we designed a filtering membrane system by using immobilized urease silk fibroin filter and evaluated its comparative effectiveness with a PVDF filtering system in peritoneal dialysate regeneration system by urea removal efficacy. We evaluated this membrane's characteristic and performances by conducting SEM-EDX analyze, water-binding abilities and porosity test, removal abilities of urea, cytotoxicity assay and enzyme activity assay. Under the condition for optimization of urease, the percentage removal of urea was about 40% and 60% in 50 mg/dL urea solution by urease immobilized PVDF and silk fibroin scaffolds, respectively. The batch experimental result showed that immobilized filter removed more than 50% of urea in 50 mg/dL urea solution. In addition silk fibroin with urease filter removed 90 percent of urea in the peritoneal dialysate after 24 h filtration. We suggest that silk fibroin with urease fixation filter can be used more effectively for peritoneal dialysate regeneration system, which have hydrophilic property and prolonged enzyme activity. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2136-2144, 2017. © 2016 Wiley Periodicals, Inc.

  8. Biological Hydrogen Production: Simultaneous Saccharification and Fermentation with Nitrogen and Phosphorus Removal from Wastewater Effluent

    DTIC Science & Technology

    2012-03-01

    the Haber - Bosch process, in which hydrogen is first produced from methane (eq. 1), then ammonia is produced from nitrogen and hydrogen: N2 (g...3H2 (g) - 2NH3 (g) (5) Agronomists have calculated that well over one-third of the world’s present population is fed by virtue of the Haber - Bosch ...fixation of nitrogen through the Haber - Bosch process, leading to a potential confluence of energy and fertilizer crises. Biological nitrogen fixation

  9. Scapulothoracic dissociation with acromioclavicular separation: a case report of a novel fixation method.

    PubMed

    Merk, Bradley R; Minihane, Keith P; Shah, Nirav A

    2008-09-01

    We present a case of 39-year-old female with a scapulothoracic dissociation and acromioclavicular (AC) separation and who had fixation of the AC joint with a locking plate, coracoclavicular screw, and transarticular AC screw. The coracoclavicular and AC relationships were maintained during postoperative rehabilitation and after hardware removal. Use of a locking plate can lead to good functional outcome without the complications associated with the use of pin and wire constructs or without violating the subacromial space.

  10. Treatment of cervical spine fractures with halo vest method in children and young people.

    PubMed

    Tomaszewski, Ryszard; Pyzińska, Marta

    2014-01-01

    The Halo Vest method is a non-invasive treatment of cervical spine fractures. It is successfully applied in adults, which is supported by numerous studies, but has rarely been used among children and young people. There is little published research in this field. The aim of the paper is to present the effectiveness of Halo Vest external fixation in children and to evaluate the complication rate of this method. A retrospective study of 6 patients with cervical spine fractures with an average age of 13.3 years (range: 10 to 17 years) treated with Halo Vest external fixation between 2004 and 2013. The type and cause of fracture, treatment outcome and complications were evaluated. The average duration of follow-up was 55 months. In 5 cases, the treatment result was satisfactory. In one case, there were complications in the form of an external infection around the cranial pins. 1. The Halo Vest system can be applied as a non-operative method of treating cervical spine fractures in children and young people. 2. The criteria of eligibility for specific types of cervical spine fracture treatment in children and young people require further investigation, especially with regard to eliminating complications.

  11. A dual-center review of compressive osseointegration for fixation of massive endoprosthetics: 2- to 9-year followup.

    PubMed

    Calvert, George T; Cummings, Judd E; Bowles, Austin J; Jones, Kevin B; Wurtz, L Daniel; Randall, R Lor

    2014-03-01

    Aseptic failure of massive endoprostheses used in the reconstruction of major skeletal defects remains a major clinical problem. Fixation using compressive osseointegration was developed as an alternative to cemented and traditional press-fit fixation in an effort to decrease aseptic failure rates. The purpose of this study was to answer the following questions: (1) What is the survivorship of this technique at minimum 2-year followup? (2) Were patient demographic variables (age, sex) or anatomic location associated with implant failure? (3) Were there any prosthesis-related variables (eg, spindle size) associated with failure? (4) Was there a discernible learning curve associated with the use of the new device as defined by a difference in failure rate early in the series versus later on? The first 50 cases using compressive osseointegration fixation from two tertiary referral centers were retrospectively studied. Rates of component removal for any reason and for aseptic failure were calculated. Demographic, surgical, and oncologic factors were analyzed using regression analysis to assess for association with implant failure. Minimum followup was 2 years with a mean of 66 months. Median age at the time of surgery was 14.5 years. A total of 15 (30%) implants were removed for any reason. Of these revisions, seven (14%) were the result of aseptic failure. Five of the seven aseptic failures occurred at less than 1 year (average, 8.3 months), and none occurred beyond 17 months. With the limited numbers available, no demographic, surgical, or prosthesis-related factors correlated with failure. Most aseptic failures of compressive osseointegration occurred early. Longer followup is needed to determine if this technique is superior to other forms of fixation.

  12. Application and Removal of Strippable Coatings via Remote Platform - 13133

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shoffner, P.; Lagos, L.; Maggio, S.

    2013-07-01

    Florida International University's (FIU's) Applied Research Center is currently supporting the Department of Energy (DOE) Environmental Management Office of D and D and Facility Engineering program. FIU is supporting DOE's initiative to improve safety, reduce technical risks, and limit uncertainty within D and D operations by identifying technologies suitable to meet specific facility D and D requirements, assessing the readiness of those technologies for field deployment, and conducting feasibility studies and technology demonstrations of selected technologies and working with technology vendors to optimize the design of their current technologies to accomplish dangerous and demanding tasks during D and D operations.more » To meet one identified technology gap challenge for a technology to remotely apply strippable coatings, fixatives and decontamination gels, FIU identified and performed an initial demonstration of an innovative remote fixative sprayer platform from International Climbing Machines (ICM). The selected technology was demonstrated spraying fixative products at the hot cell mockup facility at the Applied Research Center at FIU in November 2008 under cold (non-radioactive) conditions. The remotely controlled platform was remotely operated and entered the facility and sprayed a fixative onto horizontal and vertical surfaces. Based on the initial FIU demonstration and the specific technical requirements identified at the DOE facilities, a follow-up demonstration was expanded to include strippable coatings and a decontamination gel, which was demonstrated in June 2010 at the ICM facility in Ithaca, NY. This second technology evaluation documented the ability of the remote system to spray the selected products on vertical stainless steel and concrete surfaces to a height of 3 meters (10 feet) and to achieve sufficient coverage and product thickness to promote the ability to peel/remove the strippable coatings and decontamination gel. The next challenge was to determine if a remote platform could be used to remove the strippable coatings and decontamination gels. In 2012, FIU worked with the technology provider, ICM, to conduct feasibility and trade studies to identify the requirements for the remote removal of strippable coatings or decontamination gels using the existing remote controlled platform. (authors)« less

  13. First metatarsal-phalangeal joint arthrodesis: a biomechanical assessment of stability.

    PubMed

    Politi, Joel; John, Hayes; Njus, Glen; Bennett, Gordon L; Kay, David B

    2003-04-01

    First metatarsal phalangeal joint (MTP) arthrodesis is a commonly performed procedure for the treatment of hallux rigidus, severe and recurrent bunion deformities, rheumatoid arthritis and other less common disorders of the joint. There are different techniques of fixation of the joint to promote arthrodesis including oblique lag screw fixation, lag screw and dorsal plate fixation, crossed Kirschner wires, dorsal plate fixation alone and various types of external fixation. Ideally the fixation method should be reproducible, lead to a high rate of fusion, and have a low incidence of complications. In the present study, we compared the strength of fixation of five commonly utilized techniques of first MTP joint arthrodesis. These were: 1. Surface excision with machined conical reaming and fixation with a 3.5 mm cortical interfragmentary lag screw. 2. Surface excision with machined conical reaming and fixation with crossed 0.062 Kirschner wires. 3. Surface excision with machined conical reaming and fixation with a 3.5 mm cortical lag screw and a four hole dorsal miniplate secured with 3.5 mm cortical screws. 4. Surface excision with machined conical reaming and fixation with a four hole dorsal miniplate secured with 3.5 mm cortical screws and no lag screw. 5. Planar surface excision and fixation with a single oblique 3.5 mm interfragmentary cortical lag screw. Testing was done on an Instron materials testing device loading the first MTP joint in dorsiflexion. Liquid metal strain gauges were placed over the joint and micromotion was detected with varying loads and cycles. The most stable technique was the combination of machined conical reaming and an oblique interfragmentary lag screw and dorsal plate. This was greater than two times stronger than an oblique lag screw alone. Dorsal plate alone and Kirschner wire fixation were the weakest techniques. First MTP fusion is a commonly performed procedure for the treatment of a variety of disorders of the first MTP joint. The most stable technique for obtaining fusion in this study was the combination of an oblique lag screw and a dorsal plate. This should lead to higher rates of arthrodesis.

  14. [Treatment of sternoclavicular joint dislocation with sternoclavicular hook plate fixation].

    PubMed

    Liu, Pan; Yuan, Jia-bin; Liu, Zhong-qian; Lu, Bing; Wang, Yue

    2015-08-01

    To evaluate the technique and therapeutic effect of sternoclavicular hook plate fixation in treating sternoclavicular joint (SCJ) dislocation. From January 2010 to March 2014,6 patients with SCJ dislocation were treated with sternoclavicular hook plate fixation in our hospital. Among the 6 patients, 5 patients were male and 1 patient was female, and the average age was 34 years, ranging from 26 to 48 years. The course of the disease ranged from 3 to 20 days. All the SCJ dislocations were caused by external injury and accompanied with the symptoms of swelling pain and obvious shoulder joint activity restricted in affected side. All SCJ dislocations were anterior dislocation by the diagnosis of X-ray and CT scan. The postoperative curative effect was evaluated according to Rockwood score. All the patients' operative incision were healed well and in good appearance. X-ray showed that the dislocated SCJ was well reduced and the plate was on right position. All the 6 patients were followed up for 4 to 18 months, with an average of 12 months. The results were evaluated according to Rockwood score, 4 got excellent results, 1 good and 1 fair. No fixation loosening, redislocation or side injury such as vessel, nerve or pleura injury were found. With sternoclavicular hook plate fixation, SCJ dislocation could be reduced while keeping its amphiarthrodial function and the completeness of the cartilage surface. Sternoclavicular hook plate fixation has advantages of safety and stabilization in fixation, and patients can begin function exercises earlier.

  15. Anterior subcutaneous internal fixation for treatment of unstable pelvic fractures

    PubMed Central

    2014-01-01

    Background Fractures of the pelvic ring including disruption of the posterior elements in high-energy trauma have both high morbidity and mortality rates. For some injury pattern part of the initial resuscitation includes either external fixation or plate fixation to close the pelvic ring and decrease blood loss. In certain situations – especially when associated with abdominal trauma and the need to perform laparotomies – both techniques may put the patient at risk of either pintract or deep plate infections. We describe an operative approach to percutaneously close and stabilize the pelvic ring using spinal implants as an internal fixator and report the results in a small series of patients treated with this technique during the resuscitation phase. Findings Four patients were treated by subcutaneous placement of an internal fixator. Screw fixation was carried out by minimally invasive placement of two supra-acetabular iliac screws. Afterwards, a subcutaneous transfixation rod was inserted and attached to the screws after reduction of the pelvic ring. All patients were allowed to fully weight-bear. No losses of reduction or deep infections occurred. Fracture healing was uneventful in all cases. Conclusion Minimally invasive fixation is an alternative technique to stabilize the pelvic ring. The clinical results illustrate that this technique is able to achieve good results in terms of maintenance of reduction the pelvic ring. Also, abdominal surgeries no longer put the patient at risk of infected pins or plates. PMID:24606833

  16. Comparative study of safety and efficacy of synthetic surgical glue for mesh fixation in ventral rectopexy.

    PubMed

    Silveira, Raquel Kelner; Domingie, Sophie; Kirzin, Sylvain; de Melo Filho, Djalma Agripino; Portier, Guillaume

    2017-10-01

    Ventral mesh rectopexy (VMR) is a surgical option to treat rectal prolapse with pelvic floor dysfunction (PFD). Using synthetic surgical glue to fix the mesh to the anterior rectal wall after ventral dissection could be advantageous in comparison with sutured or stapled fixation. This study aimed to evaluate the safety and efficacy of synthetic surgical glue for mesh fixation compared with suture mesh fixation in VMR. This observational cohort study is a retrospective analysis conducted in a University Hospital Pelvic Surgery Center. All consecutive female patients (n = 176) who underwent laparoscopic or laparotomic VMR between January 2009 and December 2014 were included. Two groups were defined based on mesh fixation technique of the rectal wall: VMR with synthetic glue (n = 66) and VMR with suture (n = 110). The recurrence-free survival after VMR was determined by Kaplan-Meier method and multivariate analysis by Cox regression. Short-term postoperative complications, postoperative symptom improvement, the need for complementary treatment postoperatively, and procedure length were evaluated. A total of 176 females patients (mean age, 58.6 ± 13.7 years) underwent VMR with synthetic mesh. Mean recurrence-free survivals after VMR were 17.16 (CI 95% 16.54-17.80) and 17.33 (CI 95% 16.89-17.77) months in the glue group and the suture group, respectively (p > 0.05). Cox regression identified an independent effect on the recurrence risk of the external rectal prolapse, alone, or in combination with other anatomical abnormalities (HR = 0.37; CI 95% 0.14-0.93; p = 0.03). There was no significant difference of short-term postoperative morbidity, procedure length, postoperative symptom improvement, or need for complementary treatment postoperatively between suture versus glue groups (all p > 0.05). Use of glue to fix the mesh in VMR was safe and had no impact on outcomes. External prolapse was the unique significant predictive factor for recurrence.

  17. Posterior Vertebral Column Resection for Severe and Rigid Spinal Deformity Associated With Neurological Deficit After Implant Removal Following Posterior Instrumented Fusion: A Case Report and Literature Review.

    PubMed

    Tao, Youping; Wu, Jigong; Ma, Huasong; Zhang, Lele; Shao, Shuilin; Si, Zebing; Gao, Bo; Ji, Yong; Li, Haixia; Tao, Feifei

    2015-07-01

    Case report. To investigate the safety and efficacy of posterior vertebral column resection for severe and rigid spinal deformity associated with neurological deficit after implant removal following posterior instrumented fusion. Loss of correction after implant removal in patients with posterior instrumented fusion has been previously reported. However, to our knowledge, posterior vertebral column resection (PVCR) for severe and rigid spinal deformity associated with neurological deficit after implant removal following posterior instrumented fusion has not been reported. An 18-year-old female with severe and rigid spinal deformity associated with neurological deficit was classified as Frankel C, according to the Frankel grading system. She underwent posterior spinal fusion with pedicle screw fixation at 16 years, and her implants were removed after 1 year due to back pain. Seven months after removal of the implants, she began to experience weakness in her lower limbs but did not seek any treatment. She was unable to stand and had to use a wheelchair. The patient successfully underwent PVCR and posterior reinstrumentation. Within 3 months, her neurological status improved to Frankel E. The patient had no neurological deterioration and infections. There was no instrumentation failure and loosening correction at the 32 months follow-up. Our results suggest that PVCR and pedicle screw fixation is a safe and efficacious option for severe and rigid spinal deformity associated with neurological deficit after implant removal following posterior instrumented fusion. N/A.

  18. External fixation of proximal tracheal airway stents: a modified technique.

    PubMed

    Majid, Adnan; Fernandez-Bussy, Sebastian; Kent, Michael; Folch, Erik; Fernandez, Liliana; Cheng, George; Gangadharan, Sidhu P

    2012-06-01

    Treatment of subglottic and proximal tracheal stenosis for nonsurgical candidates includes tracheostomy, Montgomery T tubes, and silicone stents. When used in lesions with concomitant malacia, silicone stents have a high incidence of migration. We describe a simple and effective technique of securing endoluminal stents using an Endo Close suturing device (Coviden, Boston, MA) and an external silicone button in 9 consecutive patients. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Further Studies on the Lyo and Desmo Components of Several Hydrolytic Enzymes and Their Histochemical Significance

    PubMed Central

    Hannibal, Mark J.; Nachlas, Marvin M.

    1959-01-01

    This report describes additional studies of the lyo and desmo components of esterase, alkaline phosphatase, acid phosphatase, leucine aminopeptidase, and β-glucuronidase. The techniques used have already been reported (7). Enzyme diffusion occurs to different degrees in different fixatives, and varies somewhat with each enzyme. Loss of enzymatic activity during fixation occurs as a result of both inactivation due to the chemical reaction of the fixative with the enzymic protein, and diffusion of the lyo component into the fixative. The amount of diffusion into formalin can be reduced by the addition of salts, sucrose, or methocel. The pH of the aqueous medium significantly influences the removal of the lyo fraction from the tissue section. A striking similarity can be noted in the proportions of each fraction of enzyme present in the kidney of the rat, dog, and man. The procedure of fixation and paraffin embedding of tissue blocks does not wholly prevent the diffusion of the lyo component from the tissue sections when they are subsequently immersed in the aqueous incubation medium. PMID:13654449

  20. Antigen Masking During Fixation and Embedding, Dissected

    PubMed Central

    Scalia, Carla Rossana; Boi, Giovanna; Bolognesi, Maddalena Maria; Riva, Lorella; Manzoni, Marco; DeSmedt, Linde; Bosisio, Francesca Maria; Ronchi, Susanna; Leone, Biagio Eugenio; Cattoretti, Giorgio

    2016-01-01

    Antigen masking in routinely processed tissue is a poorly understood process caused by multiple factors. We sought to dissect the effect on antigenicity of each step of processing by using frozen sections as proxies of the whole tissue. An equivalent extent of antigen masking occurs across variable fixation times at room temperature. Most antigens benefit from longer fixation times (>24 hr) for optimal detection after antigen retrieval (AR; for example, Ki-67, bcl-2, ER). The transfer to a graded alcohol series results in an enhanced staining effect, reproduced by treating the sections with detergents, possibly because of a better access of the polymeric immunohistochemical detection system to tissue structures. A second round of masking occurs upon entering the clearing agent, mostly at the paraffin embedding step. This may depend on the non-freezable water removal. AR fully reverses the masking due both to the fixation time and the paraffin embedding. AR itself destroys some epitopes which do not survive routine processing. Processed frozen sections are a tool to investigate fixation and processing requirements for antigens in routine specimens. PMID:27798289

  1. Induction of uncoiled chromosomes by vibration.

    PubMed

    Delinassios, J G

    1979-02-15

    Chromatin condensation during metaphase can be removed by simple vibration of metaphase cells prior to fixation. Uncoiled chromosome arms consist of long threads with dense regions at irregular distances each from the other.

  2. An efficient copper-based magnetic nanocatalyst for the fixation of carbon dioxide at atmospheric pressure.

    PubMed

    Sharma, Rakesh Kumar; Gaur, Rashmi; Yadav, Manavi; Goswami, Anandarup; Zbořil, Radek; Gawande, Manoj B

    2018-01-30

    In the last few decades, the emission of carbon dioxide (CO 2 ) in the environment has caused havoc across the globe. One of the most promising strategies for fixation of CO 2 is the cycloaddition reaction between epoxides and CO 2 to produce cyclic carbonates. For the first time, we have fabricated copper-based magnetic nanocatalyst and have applied for the CO 2 fixation. The prepared catalyst was thoroughly characterized using various techniques including XRD, FT-IR, TEM, FE-SEM, XPS, VSM, ICP-OES and elemental mapping. The reactions proceeded at atmospheric pressure, relatively lower temperature, short reaction time, solvent- less and organic halide free reaction conditions. Additionally, the ease of recovery through an external magnet, reusability of the catalyst and excellent yields of the obtained cyclic carbonates make the present protocol practical and sustainable.

  3. Plate versus intramedullary fixation of two-part and multifragmentary displaced midshaft clavicle fractures - a long-term analysis.

    PubMed

    Chan, Gareth; Korac, Zelimir; Miletic, Matija; Vidovic, Dinko; Phadnis, Joideep; Bakota, Bore

    2017-11-01

    Surgical fixation of displaced midshaft clavicle fractures is predominantly achieved with intramedullary (IM) or plate fixation. Both techniques have potential pitfalls: plate fixation involves greater periosteal stripping and protuberance of the implant, whereas IM fixation may be associated with implant-related complications, such as migration or skin irritation, which may lead to further surgery for implant removal. The aim of this study was to compare these two methods in simple (Robinson 2b.1) and multifragmentary (Robinson 2b.2) displaced midshaft clavicle fractures. A total of 133 consecutive patients who underwent surgical fixation for a displaced midshaft clavicle fracture with either IM fixation using a 2.5-mm Kirschner wire or plate fixation using an 8-hole Dynamic Compression Plate (DCP) were retrospectively reviewed. Follow-up was a minimum of 1 year. The patients were allocated into two injury groups: displaced simple 2-part fractures (64 IM vs. 16 DCP) and displaced multifragmentary fractures (27 IM vs. 26 DCP). The major observed outcome measures were: infection rate, non-union rate, reoperation rate and postoperative range of motion (ROM). Rates of non-union for displaced 2-part fractures were 2/64 (3.13%) with IM fixation and 0/16 (0.00%) with plate fixation (p = 0.477). For displaced multifragmentary fractures, rates of non-union were 2/27 (7.41%) with IM fixation and 0/26 (0.00%) with plate fixation (p = 0.161). No significant difference was observed between the two fixation modalities in patient-reported time to regain ROM on the injured side for displaced 2-part fractures (p = 0.129) and displaced multifragmentary fractures (p = 0.070). Deep infection rate was zero (p = 1.000) overall in the study, and reoperation rate for IM and plate fixation, respectively, was 3.13% and 6.25% in the Robinson 2b.1 group (p = 0.559) and 7.41% and 7.69% in the Robinson 2b.2 group (p = 0.969). IM fixation of displaced midshaft clavicle fractures (Robinson 2b.1) has an equivalent non-union rate to plate fixation and similarly low complication and reoperation rates. For displaced midshaft multifragmentary clavicle fractures (Robinson 2b.2), the higher non-union rates observed with IM fixation leads us to recommend consideration of plate fixation for Robinson 2b.2 fractures. © 2017 Elsevier Ltd. All rights reserved.

  4. Tibial lengthening over intramedullary nails

    PubMed Central

    Burghardt, R. D.; Manzotti, A.; Bhave, A.; Paley, D.

    2016-01-01

    Objectives The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method. Methods In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group. Results The mean external fixation time for the LON group was 2.6 months and for the matched case group was 7.6 months. The mean lengthening amounts for the LON and the matched case groups were 5.2 cm and 4.9 cm, respectively. The radiographic consolidation time in the LON group was 6.6 months and in the matched case group 7.6 months. Using a clinical and radiographic outcome score that was designed for this study, the outcome was determined to be excellent in 17 and good in two patients for the LON group. The outcome was excellent in 14 and good in five patients in the matched case group. The LON group had increased blood loss and increased cost. The LON group had four deep infections; the matched case group did not have any deep infections. Conclusions The outcomes in the LON group were comparable with the outcomes in the matched case group. The LON group had a shorter external fixation time but experienced increased blood loss, increased cost, and four cases of deep infection. The advantage of reducing external fixation treatment time may outweigh these disadvantages in patients who have a healthy soft-tissue envelope. Cite this article: J. E. Herzenberg. Tibial lengthening over intramedullary nails: A matched case comparison with Ilizarov tibial lengthening. Bone Joint Res 2016;5:1–10. doi: 10.1302/2046-3758.51.2000577 PMID:26764351

  5. Effects of Carbon Dioxide and Oxygen on the Regulation of Photosynthetic Carbon Metabolism by Ammonia in Spinach Mesophyll Cells 1

    PubMed Central

    Lawyer, Arthur L.; Cornwell, Karen L.; Larsen, Peder O.; Bassham, James A.

    1981-01-01

    Photosynthetic carbon metabolism of isolated spinach mesophyll cells was characterized under conditions favoring photorespiratory (PR; 0.04% CO2 and 20% O2) and nonphotorespiratory (NPR; 0.2% CO2 and 2% O2) metabolism, as well as intermediate conditions. Comparisons were made between the metabolic effects of extracellularly supplied NH4+ and intracellular NH4+, produced primarily via PR metabolism. The metabolic effects of 14CO2 fixation under PR conditions were similar to perturbations of photosynthetic metabolism brought about by externally supplied NH4+; both increased labeling and intracellular concentrations of glutamine at the expense of glutamate and increased anaplerotic synthesis through α-ketoglutarate. The metabolic effects of added NH4+ during NPR fixation were greater than those during PR fixation, presumably due to lower initial NH4+ levels during NPR fixation. During PR fixation, addition of ammonia caused decreased pools and labeling of glutamate and serine and increased glycolate, glyoxylate, and glycine labeling. The glycolate pathway was thus affected by increased rates of carbon flow and decreased glutamate availability for glyoxylate transamination, resulting in increased usage of serine for transamination. Sucrose labeling decreased with NH4+ addition only during PR fixation, suggesting that higher photosynthetic rates under NPR conditions can accommodate the increased drain of carbon toward amino acid synthesis while maintaining sucrose synthesis. PMID:16662084

  6. [Miniplate internal fixation and autogenous iliac bone graft in surgical treatment of old metatarsal fractures].

    PubMed

    Pan, Hao; Yu, Guangrong; Xiong, Wen; Zhao, Zhiming; Ding, Fan; Zheng, Qiong; Kan, Wushen

    2011-07-01

    To summarize the experience of treating old metatarsal fractures with surgery methods of miniplate internal fixation and autogenous iliac bone. Between May 2009 and July 2010, 7 patients with old metatarsal fractures were treated surgically, including 5 multi-metatarsal fractures and 2 single metatarsal fractures. There were 5 males and 2 females aged from 25 to 43 years (mean, 33 years). The time from fracture to operation was 4-12 weeks. The X-ray films showed that a small amount of callus formed at both broken ends with shortening, angulation, or rotation displacement. The surgical treatments included open reduction, internal fixation by miniplate, and autogenous iliac bone graft (1.5-2.5 cm(3)). The external plaster fixation was used in all patients for 4 to 6 weeks postoperatively (mean, 5 weeks). All incisions healed by first intention. The 7 patients were followed up 8-18 months (mean, 13.5 months). The clinical fracture healing time was 6 to 12 weeks postoperatively (mean, 8.4 weeks). No pain of planta pedis occurred while standing and walking. The American Orthopaedic Foot and Ankle Society (AOFAS) mesopedes and propodium score was 75-96 (mean, 86.4). It has the advantages of reliable internal fixation, high fracture healing rate, less complications to treat old metatarsal fractures with surgery methods of miniplate internal fixation and autogenous iliac bone graft, so it is an effective treatment method.

  7. Fixation method does not affect restoration of rotation center in hip replacements: A single-site retrospective study

    PubMed Central

    2012-01-01

    Background Aseptic loosening is one of the greatest problems in hip replacement surgery. The rotation center of the hip is believed to influence the longevity of fixation. The aim of this study was to compare the influence of cemented and cementless cup fixation techniques on the position of the center of rotation because cemented cup fixation requires the removal of more bone for solid fixation than the cementless technique. Methods We retrospectively compared pre- and post-operative positions of the hip rotation center in 25 and 68 patients who underwent artificial hip replacements in our department in 2007 using cemented or cementless cup fixation, respectively, with digital radiographic image analysis. Results The mean horizontal and vertical distances between the rotation center and the acetabular teardrop were compared in radiographic images taken pre- and post-operatively. The mean horizontal difference was −2.63 mm (range: -11.00 mm to 10.46 mm, standard deviation 4.23 mm) for patients who underwent cementless fixation, and −2.84 mm (range: -10.87 to 5.30 mm, standard deviation 4.59 mm) for patients who underwent cemented fixation. The mean vertical difference was 0.60 mm (range: -20.15 mm to 10.00 mm, standard deviation 3.93 mm) and 0.41 mm (range: -9.26 mm to 6.54 mm, standard deviation 3.58 mm) for the cementless and cemented fixation groups, respectively. The two fixation techniques had no significant difference on the position of the hip rotation center in the 93 patients in this study. Conclusions The hip rotation center was similarly restored using either the cemented or cementless fixation techniques in this patient cohort, indicating that the fixation technique itself does not interfere with the position of the center of rotation. To completely answer this question further studies with more patients are needed. PMID:22686355

  8. Rigid removable cover for dorsal wound protection and tube fixation in pigs.

    PubMed

    Stynes, G D; Kiroff, G K; Morrison, W A; Edwards, G A; Page, R S; Kirkland, M A

    2016-04-01

    To report the design and benefits of a rigid polyethylene cover 'shell' for the protection of dorsal torso wounds and tube fixation in pigs. Open C-shaped polyethylene shells were designed to protect wounds and dressings on the dorsum of pigs used in research into negative pressure dressing-assisted wound healing. The shells were designed to resist trauma and contamination, to be comfortable and expansible, and to facilitate tube fixation and management. Strap fixation was optimised during experimentation. Efficacy was assessed by direct observation of dressing and wound protection, tube integrity and by macroscopic and microscopic assessments of wound healing. The shells effectively protected the wounds against blunt and sharp trauma, were simple to remove and reapply, were well tolerated and allowed for growth of the pigs. Circumferential neck straps attached by lateral straps to the shells proved critical. There was no wound infection or inflammation underlying the shells. Porting tubing via mid-dorsal holes in the shells and affixing the tubing just cranial to these holes prevented tube damage and traction, permitted tube management from outside the cages and allowed the pigs to move freely without becoming entangled. These shells effectively protected dorsal skin wounds and dressings, prevented tube damage and facilitated tube management in pigs. Similar systems may be useful for other production animals for wound management and for tube management with negative pressure wound healing, drain tubes or the delivery of nutrition, fluids or medications. © 2016 Australian Veterinary Association.

  9. Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

    PubMed

    Kampf, Günter; Fliss, Patricia M; Martiny, Heike

    2014-09-16

    The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes.

  10. Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

    PubMed Central

    Kampf, Günter; Fliss, Patricia M; Martiny, Heike

    2014-01-01

    The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes. PMID:25228941

  11. Fractures of the proximal fifth metatarsal: percutaneous bicortical fixation.

    PubMed

    Mahajan, Vivek; Chung, Hyun Wook; Suh, Jin Soo

    2011-06-01

    Displaced intraarticular zone I and displaced zone II fractures of the proximal fifth metatarsal bone are frequently complicated by delayed nonunion due to a vascular watershed. Many complications have been reported with the commonly used intramedullary screw fixation for these fractures. The optimal surgical procedure for these fractures has not been determined. All these observations led us to evaluate the effectiveness of percutaneous bicortical screw fixation for treating these fractures. Twenty-three fractures were operatively treated by bicortical screw fixation. All the fractures were evaluated both clinically and radiologically for the healing. All the patients were followed at 2 or 3 week intervals till fracture union. The patients were followed for an average of 22.5 months. Twenty-three fractures healed uneventfully following bicortical fixation, with a mean healing time of 6.3 weeks (range, 4 to 10 weeks). The average American Orthopaedic Foot & Ankle Society (AOFAS) score was 94 (range, 90 to 99). All the patients reported no pain at rest or during athletic activity. We removed the implant in all cases at a mean of 23.2 weeks (range, 18 to 32 weeks). There was no refracture in any of our cases. The current study shows the effectiveness of bicortical screw fixation for displaced intraarticular zone I fractures and displaced zone II fractures. We recommend it as one of the useful techniques for fixation of displaced zone I and II fractures.

  12. Aphotic N2 fixation along an oligotrophic to ultraoligotrophic transect in the western tropical South Pacific Ocean

    NASA Astrophysics Data System (ADS)

    Benavides, Mar; Shoemaker, Katyanne M.; Moisander, Pia H.; Niggemann, Jutta; Dittmar, Thorsten; Duhamel, Solange; Grosso, Olivier; Pujo-Pay, Mireille; Hélias-Nunige, Sandra; Fumenia, Alain; Bonnet, Sophie

    2018-05-01

    The western tropical South Pacific (WTSP) Ocean has been recognized as a global hot spot of dinitrogen (N2) fixation. Here, as in other marine environments across the oceans, N2 fixation studies have focused on the sunlit layer. However, studies have confirmed the importance of aphotic N2 fixation activity, although until now only one had been performed in the WTSP. In order to increase our knowledge of aphotic N2 fixation in the WTSP, we measured N2 fixation rates and identified diazotrophic phylotypes in the mesopelagic layer along a transect spanning from New Caledonia to French Polynesia. Because non-cyanobacterial diazotrophs presumably need external dissolved organic matter (DOM) sources for their nutrition, we also identified DOM compounds using Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) with the aim of searching for relationships between the composition of DOM and non-cyanobacterial N2 fixation in the aphotic ocean. N2 fixation rates were low (average 0.63 ± 0.07 nmol N L-1 d-1) but consistently detected across all depths and stations, representing ˜ 6-88 % of photic N2 fixation. N2 fixation rates were not significantly correlated with DOM compounds. The analysis of nifH gene amplicons revealed a wide diversity of non-cyanobacterial diazotrophs, mostly matching clusters 1 and 3. Interestingly, a distinct phylotype from the major nifH subcluster 1G dominated at 650 dbar, coinciding with the oxygenated Subantarctic Mode Water (SAMW). This consistent pattern suggests that the distribution of aphotic diazotroph communities is to some extent controlled by water mass structure. While the data available are still too scarce to elucidate the distribution and controls of mesopelagic non-cyanobacterial diazotrophs in the WTSP, their prevalence in the mesopelagic layer and the consistent detection of active N2 fixation activity at all depths sampled during our study suggest that aphotic N2 fixation may contribute significantly to fixed nitrogen inputs in this area and/or areas downstream of water mass circulation.

  13. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable.

    PubMed

    Thorborg, Kristian; Bandholm, Thomas; Hölmich, Per

    2013-03-01

    In football, ice-hockey, and track and field, injuries have been predicted, and hip- and knee-strength deficits quantified using hand-held dynamometry (HHD). However, systematic bias exists when testers of different sex and strength perform the measurements. Belt-fixation of the dynamometer may resolve this. The aim of the present study was therefore to examine the inter-tester reliability concerning strength assessments of isometric hip abduction, adduction, flexion, extension and knee-flexion strength, using HHD with external belt-fixation. Twenty-one healthy athletes (6 women), 30 (8.6) (mean (SD)) years of age, were included. Two physiotherapy students (1 female and 1 male) performed all the measurements after careful instruction and procedure training. Isometric hip abduction, adduction, flexion, extension, and knee-flexion strength were tested. The tester-order and hip-action order were randomised. No systematic between-tester differences (bias) were observed for any of the hip or knee actions. The intra-class correlation coefficients (ICC 2.1) ranged from 0.76 to 0.95. Furthermore, standard errors of measurement in per cent (SEM %) ranged from 5 to 11 %, and minimal detectable change in per cent (MDC %) from 14 to 29 % for the different hip and knee actions. The present study shows that isometric hip- and knee-strength measurements have acceptable inter-tester reliability at the group level, when testing strong individuals, using HHD with belt-fixation. This procedure is therefore perfectly suited for the evaluation and monitoring of strong athletes with hip, groin and hamstring injuries, some of the most common and troublesome injuries in sports. Diagnostic, Level III.

  14. [Comparison of the treatment of slipped capital femoral epiphysis with K-wires and cannulated titanium screws].

    PubMed

    Maus, U; Ihme, N; Niedhart, C; Abeler, E; Kochs, A; Gravius, S; Ohnsorge, J A K; Andereya, S

    2008-01-01

    The treatment of slipped capital femoral epiphysis (SCFE) is usually treated operatively, but there is still no consensus about the method to be used. Up to a 30 degrees degree of slipping, the epiphysis is normally fixed in situ. The aim of our study was to compare the intermediate results after fixation in situ by K-wires versus cannulated titanium screws (Königsee-Implantate, Königsee-Aschau, Germany). In this study 46 patients with SCFE grade I and II and mostly chronic slipping of the epiphysis were included. After fixation in situ and, if necessary, careful, closed reposition, the patients were clinically and radiologically followed-up for one year. The clinical results were documented by the score adapted from Heyman and Herndon. Furthermore, MRI scans were done to evaluate the vitality of the epiphysis pre- and postoperatively, when titanium screws were used. Clinical follow-up showed comparable results in the clinical scores after fixation by K-wires or cannulated titanium screws (3.13 +/- 1.02 vs. 3.10 +/- 1.01). After the treatment with titanium screws we saw a higher rate of abnormal gait (33.3 % vs. 19 %), a decreased rate of the positive Drehmann sign (10 % vs. 38 %) and a lower rate of revisions (16 % vs. 50 %) in comparison to K-wire fixation. After displacement of the K-wires we saw chondrolysis and prearthrosis in one case. Removal of the K-wires was done without any complications, while the removal of the cannulated titanium screws failed in 4 of 10 cases. The treatment of SCFE with K-wires and cannulated titanium screws showed comparable results in the clinical follow-up. The treatment with cannulated titanium screws reduces the number of necessary revisions, but the removal of the material is hindered. Because of the lower rate of complications we prefer in the meantime the use of cannulated steel screws.

  15. Injectable suture device for intraocular lens fixation.

    PubMed

    Smith, Jesse M; Erlanger, Michael; Olson, Jeffrey L

    2015-12-01

    We describe a surgical technique for scleral fixation of a posterior chamber intraocular lens (PC IOL) using a 24-gauge injectable polypropylene suture delivery system. A 3-piece PC IOL is inserted into the anterior chamber of the eye. Two sclerotomies are made 1.5 mm posterior to the limbus using a microvitreoretinal blade. The 24-gauge injector delivers a preformed suture loop into the eye with the double-armed needles still external to the eye. Each polypropylene IOL haptic is directed through the loop using microforceps. The suture loop is tightened around the haptic, and the attached needles are used to fixate the IOL to the sclera and close the sclerotomies simultaneously. This technique has been used in an ex vivo porcine eye and in an aphakic patient. In the latter, the IOL was quickly fixated to the sclera and maintained a stable position postoperatively. Dr. Olson has a patent pending for the device described in this article. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Malleolar fractures and their ligamentous injury equivalents have similar outcomes in supination-external rotation type IV fractures of the ankle treated by anatomical internal fixation.

    PubMed

    Berkes, M B; Little, M T M; Lazaro, L E; Sculco, P K; Cymerman, R M; Daigl, M; Helfet, D L; Lorich, D G

    2012-11-01

    It has previously been suggested that among unstable ankle fractures, the presence of a malleolar fracture is associated with a worse outcome than a corresponding ligamentous injury. However, previous studies have included heterogeneous groups of injury. The purpose of this study was to determine whether any specific pattern of bony and/or ligamentous injury among a series of supination-external rotation type IV (SER IV) ankle fractures treated with anatomical fixation was associated with a worse outcome. We analysed a prospective cohort of 108 SER IV ankle fractures with a follow-up of one year. Pre-operative radiographs and MRIs were undertaken to characterise precisely the pattern of injury. Operative treatment included fixation of all malleolar fractures. Post-operative CT was used to assess reduction. The primary and secondary outcome measures were the Foot and Ankle Outcome Score (FAOS) and the range of movement of the ankle. There were no clinically relevant differences between the four possible SER IV fracture pattern groups with regard to the FAOS or range of movement. In this population of strictly defined SER IV ankle injuries, the presence of a malleolar fracture was not associated with a significantly worse clinical outcome than its ligamentous injury counterpart. Other factors inherent to the injury and treatment may play a more important role in predicting outcome.

  17. Postoperative complications associated with external skeletal fixators in cats.

    PubMed

    Beever, Lee; Giles, Kirsty; Meeson, Richard

    2017-07-01

    The objective of this study was to quantify complications associated with external skeletal fixators (ESFs) in cats and to identify potential risk factors. A retrospective review of medical records and radiographs following ESF placement was performed. Case records of 140 cats were reviewed; fixator-associated complications (FACs) occurred in 19% of cats. The region of ESF placement was significantly associated with complication development. Complications developed most frequently in the femur (50%), tarsus (35%) and radius/ulna (33%). Superficial pin tract infection (SPTI) and implant failure accounted for 45% and 41% of all FACs, respectively. SPTI occurred more frequently in the femur, humerus and tibia, with implant failure more frequent in the tarsus. No association between breed, age, sex, weight, fracture type (open vs closed), ESF classification, number of pins per bone segment, degree of fracture load sharing, and the incidence or type of FAC was identified. No association between region of placement, breed, age, sex, weight, fracture type (open vs closed), ESF classification, number of pins per bone segment, fracture load sharing and the time to complication development was identified. Complication development is not uncommon in cats following ESF placement. The higher complication rate in the femur, tarsus and radius/ulna should be considered when reviewing options for fracture management. However, cats appear to have a lower rate of pin tract infections than dogs.

  18. Limb lengthening in short-stature patients using monolateral and circular external fixators.

    PubMed

    Lie, Chester W H; Chow, W

    2009-08-01

    To review the results of distraction osteogenesis in short-stature patients in our centre and analyse outcomes including complications. Retrospective study. University teaching hospital, Hong Kong. Eight patients with short stature (three had achondroplasia, three constitutional short stature, and two hypochondroplasia) operated on for limb lengthening using monolateral or circular external fixators between 1995 and 2006 were reviewed. The mean age at the time of surgery was 20 years (range, 9-39 years). The fixators used were either Ilizarov or Orthofix. The average gain in length per bone segment was 5.2 cm (range, 3.2-8.0 cm), and the average percentage lengthening was 21% (range, 7.9-40%). The mean time in frame was 8 months (range, 4-14 months), and the average healing index was 48 days per cm of lengthening (18-110 days per cm). Minor complications (pin tract infection and transient joint stiffness) were common, and after excluding the latter the overall complication rate was 0.6 per bone segment. In our series, limb lengthening of up to 40% of the initial length of the bone segment can be achieved without significant long-term sequelae. However, the procedures were complex and prolonged, and required a special psychological approach directed at both parents and the patients. Complications are quite common, for which patients have to be well prepared before starting the procedures.

  19. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desai, Shamit S., E-mail: shamit.desai@northwestern.edu; Konanur, Meghana; Foltz, Gretchen

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared andmore » externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.« less

  20. Outcome of 28 open pilon fractures with injury severity-based fixation.

    PubMed

    Danoff, Jonathan R; Saifi, Comron; Goodspeed, David C; Reid, J Spence

    2015-04-01

    Open pilon fracture management and treatment poses a significant challenge to orthopedic surgeons. The purpose of this study was to determine patient outcomes for open pilon fractures based on wound complication and infection rates, as well as subjective outcome instruments. This was a retrospective consecutive case series of 28 fractures with Orthopaedic Trauma Association (OTA)-type 43-B and 43-C open pilon fractures. Mean length of follow-up was 36 months and minimum of 1 year. Ten fractures were Gustilo and Anderson grade IIIB, and the remaining fractures were grades I-IIIA. Patients were initially treated with spanning external fixation and staged wound debridement followed by osteosynthesis of the articular surface. Metaphyseal fixation was by either plate fixation or Ilizarov frame. The primary outcome was the incidence of deep tissue infection requiring surgery. Secondary outcomes included the incidence of other complications (nonunion, malunion, amputation) and functional outcomes (Short Musculoskeletal Functional Assessment Questionnaire and AAOS Foot and Ankle Questionnaire). Four patients developed deep tissue infections, three in the internal fixation group and one in the Ilizarov group, and all were treated successfully with staged debridement. There were two delayed unions required bone grafting, and infection-free union was ultimately achieved in all fractures. Two patients underwent arthrodesis secondary to post-traumatic arthritis, while no patients experienced malunions or amputations. The use of staged wound debridement in conjunction with either plate fixation or Ilizarov frame achieves low rates of wound infection and stable fixation after anatomic joint reconstruction for OTA-type 43-B and 43-C open pilon fractures.

  1. Scapular thickness--implications for fracture fixation.

    PubMed

    Burke, Charity S; Roberts, Craig S; Nyland, John A; Radmacher, Paula G; Acland, Robert D; Voor, Michael J

    2006-01-01

    The purpose of this study was to measure and map scapula osseous thickness to identify the optimal areas for internal fixation. Eighteen (9 pairs) scapulae from 2 female and 7 male cadavers were used. After harvest and removal of all soft tissues, standardized measurement lines were made based on anatomic landmarks. For consistency among scapulae, measurements were taken at standard percentage intervals along each line approximating the distance between two consecutive reconstruction plate screw holes. Two-mm-diameter drill holes were made at each point, and a standard depth gauge was used to measure thickness. The glenoid fossa (25 mm) displayed the greatest mean osseous thickness, followed by the lateral scapular border (9.7 mm), the scapula spine (8.3 mm), and the central portion of the body of the scapula (3.0 mm). To optimize screw purchase and internal fixation strength, the lateral border, the lateral aspect of the base of the scapula spine, and the scapula spine itself should be used for anatomic sites of internal fixation of scapula fractures.

  2. Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures

    PubMed Central

    Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed

    2014-01-01

    This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3–12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and 12 months postoperatively. Radiographs were done at 1 week, 3 months, and 12 months postoperatively to observe any displacement and fracture healing. All fractures healed both clinically and radiologically. No serious complications were reported in the patients. Normal occlusion was achieved in all cases. Biodegradable osteofixation of mandibular fractures offers a valuable clinical solution for pediatric patients getting the benefit of avoiding secondary surgery to remove plates, decreasing the hospital stay, further painful procedures, and psychological impact. PMID:26269728

  3. Endoscopic suture fixation is associated with reduced migration of esophageal fully covered self-expandable metal stents (FCSEMS).

    PubMed

    Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan

    2017-09-01

    Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.

  4. [Unstable thorax fixation with bioabsorbable plates and screws. Presentation of some cases].

    PubMed

    Nolasco-de la Rosa, Ana Lilia; Mosiñoz-Montes, Roberto; Matehuala-García, Jesús; Román-Guzmán, Edgardo; Quero-Sandoval, Fidel; Reyes-Miranda, Alma Lorena

    2015-01-01

    Flail chest is managed with mechanical ventilation or inhalation therapy, and analgesia. Mechanical ventilations carry risks by themselves and disengage with the external fixators so they must be operated to improve lung ventilatory mechanics and cleaning. Little has been published on the use of bioabsorbable material and its evolution in the setting of flail chest. A material that did had to be retired, that presented the malleability of titanium and its inflammatory reaction was minimal and could be handled in both adults and children was investigated. Here is shown a descriptive study of patients with flail chest under rib fixation with plates and bioabsorbable screws. 18 cases are presented, aged 33-74 years, three with bilateral flail chest; fixation was performed between days 1-21 of the accident. In cases that showed no fractures pelvic limbs, gait next day restarted fi ng in all cases improved mechanical ventilation, pain decreased, none has so far presented reaction material. Flail chest has a high (16.3%) mortality when no management provides the pathophysiology of the condition (pain, poor mechanical ventilation, alveolar edema-pulmonary contusion). The use of bioabsorbable material has no side effects attributable to material which is another option for rib fixation. Copyright © 2015. Published by Masson Doyma México S.A.

  5. [Clinical randomized controlled trial on ultrashort wave and magnetic therapy for the treatment of early stage distal radius fractures].

    PubMed

    Wang, Guan-Jie; Liu, Jia

    2012-07-01

    To explore the effect of application of ultrashort wave and magnetic therapy instrument on the swelling regression in distal radius fractures treated by splint external fixation in initial stage. From March 2007 to May 2010,90 patients with distal radial fracture were treated by manual reduction and splint external fixation. After manual reduction and small splints external fixation, these patients were randomly divided into electrical physical therapy group, western medicine group and the control group by the order of calling number, with 30 cases each group. In control group, there were 9 males and 21 females with an average age of (61.29 +/- 1.97) years, the patients raised and exercise the limb and fingers only. The other two groups also carried out this treatment. In electrical physical therapy group, there were 9 males and 21 females with an average age of (62.37 +/- 2.48) years, the patients were treated with ultrashort wave and magnetic therapy instrument for early intervention, once a day, 5 days for a course of treatment and three cycle were operated. In western medicine group,there were 8 males and 22 females with an average age of (60.12 +/- 2.87) years, the patients were injected with beta-aescin (20 mg, intravenous injection,once a day) for 5 days, followed by Danshen injection (20 ml, intravenous injection, once a day) for 10 days. The limb swelling of patients were assessed every day for 20 days after manual reduction and small splints external fixation. The time of swelling regression in electrical physical therapy group, western medicine group and the control group were respectively (9.62 +/- 3.32), (10.05 +/- 3.05) and (14.57 +/- 2.93) days. Both of that in electrical physical therapy group and western medicine group were shorter than that in the control group (P<0.05), then there were not statistical difference between electrical physical therapy group and western medicine group (P>0.05). The effective rate of swelling regression in electrical physical therapy group, western medicine group and the control group were 86.67%, 80.00%, 46.66% respectively. There was no significant differences between electrical physical therapy group and western medicine group in the curative effect, but both of them had advantage over the control group. Application of ultrashort wave and magnetic therapy instrument for treatment of distal radial fractures in initial stage can promote the regression of limb swelling evidently, which is similar to the intravenous infusion of beta-aescin injection and Danshen injection in curative effect.

  6. [Early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect].

    PubMed

    Xiao, Jian; Mao, Zhao-Guang; Zhu, Hui-Hua; Guo, Liang

    2017-03-25

    To discuss the curative effect of the early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect. From December 2013 to January 2015, 36 cases of lower limb open comminuted fractures complicated with bone defects were treated by the vancomycin ALBC combined with the external fixation support, including 26 males and 10 females with an average age of 38.0 years old ranging from 19 to 65 years old. The included cases were all open fractures of lower limbs complicated with bone defects with different degree of soft tissue injuries. Among them, 25 cases were tibial fractures, 11 cases were femoral fractures. The radiographs indicated a presence of bone defects, which ranged from 3.0 to 6.1 cm with an average of 4.0 cm. The Gustilo classification of open fractures:24 cases were type IIIA, 12 cases were typr IIIB. The percentage of wound infection, bone grafting time, fracture healing time and postoperative joint function of lower limb were observed. The function of injured limbs was evaluated at 1 month after the clinical healing of fracture based on Paley evaluation criterion. All cases were followed up for 3 to 24 months with an average of (6.0±3.0) months. The wound surface was healed well, neither bone infections nor unhealed bone defects were presented. The reoperation of bone grafting was done at 6 weeks after the patients received an early treatment with ALBC, some of them were postponed to 8 weeks till the approximate healing of fractures, the treatment course lasted for 4 to 8 months with an average of(5.5±1.5) months. According to Paley and other grading evaluations of bone and function, there were 27 cases as excellent, 5 cases as good, 3 cases as ordinary. The ALBC combined with external fixation support was an effective method for early treatment to treat the traumatic lower limb open fractures complicated with bone defects. This method was typified with the advantages such as easy operation, short operation time, overwhelming superiority in controlling infection and provision of good bone grafting bed, a good bone healing can be realized by the use of membrane induction technology for bone grafting.

  7. Effects of fixation and demineralization on bone collagen D-spacing as analyzed by atomic force microscopy.

    PubMed

    Wallace, Joseph M

    2015-04-01

    Collagen's role in bone is often considered secondary. As increased attention is paid to collagen, understanding the impact of tissue preservation is important in interpreting experimental results. The goal of this study was to test the hypothesis that bone fixation prior to demineralization would maintain its collagen ultrastructure in an undisturbed state when analyzed using Atomic Force Microscopy (AFM). The anterior diaphysis of a pig femur was cut into 6 mm pieces along its length. Samples were mounted, polished and randomly assigned to control or fixation groups (n = 5/group). Fixation samples were fixed for 24 h prior to demineralization. All samples were briefly demineralized to expose collagen, and imaged using AFM. Mouse tail tendons were also analyzed to explore effects of dehydration and fixation. Measurements from each bone sample were averaged and compared using a Mann-Whitney U-test. Tendon sample means were compared using RMANOVA. To investigate differences in D-spacing distributions, Kolmogorov-Smirnov tests were used. Fixation decreased D-spacing variability within and between bone samples and induced or maintained a higher average D-spacing versus control by shifting the D-spacing population upward. Tendon data indicate that fixing and drying samples leaves collagen near its undisturbed and hydrated native state. Fixation in bone prior to demineralization decreased D-spacing variability. D-spacing was shifted upward in fixed samples, indicating that collagen is stretched with mineral present and relaxes upon its removal. The ability to decrease variability in bone suggests that fixation might increase the power to detect changes in collagen due to disease or other pressures.

  8. Nitrogen Fixation by Anaerobes is Stimulated by Low Oxygen and Insensitive to Combined Nitrogen in Coastal Sediments

    NASA Astrophysics Data System (ADS)

    Jenkins, B. D.; Spinette, R.; Jones, A.; Puggioni, G.; Ehrlich, A.; Brown, S. M.

    2016-02-01

    Coastal sediments are typically zones of nitrogen removal via coupled nitrification-denitrification pathways. Increasingly, there are reports of nitrogen fixation in anthropogenically impacted sediments containing ample combined nitrogen. In previous work in the estuarine sediments of Narragansett Bay, we found that anaerobes related to Desulfovibrio spp. and in the Desulfuromonadales express genes for nitrogen fixation (nifH). We also determined that nitrogen fixation rates and gene expression are elevated during periods of seasonal hypoxia. Statistical modeling shows that a combination of elevated phytoplankton biomass as with a duration of hypoxia for a week or longer lead to conditions that promote nitrogen fixation as measured by acetylene reduction. Interestingly, diazotrophs closely related to those identified in Narragansett Bay are present and active in other low oxygen systems, suggesting that expansion of hypoxic events may lead to unanticipated consequences for the benthic nitrogen cycle in many ecosystems. To determine controls on diazotrophy on the organismal level, we isolated and sequenced the genomes of two Narragansett Bay members of the Desulfovibrio. We found that these organisms are insensitive to nitrate and urea, as they are missing the genes to assimilate these nitrogen sources. However, their nitrogen fixation is suppressed by increasing concentrations of ammonium, indicating that they may be sensitive to this nitrogen source in the environment. The paradox of detectable nitrogen fixation in the background of measurable ammonium in estuarine systems is a newly emergent theme and suggests that there are complex microbial interactions and/or structure to the nutrient regimes allowing for fixation.

  9. Black bone disease in a healing fracture.

    PubMed

    Thiam, Desmond; Teo, Tse Yean; Malhotra, Rishi; Tan, Kong Bing; Chee, Yu Han

    2016-01-28

    Black bone disease refers to the hyperpigmentation of bone secondary to prolonged usage of minocycline. We present a report of a 34-year-old man who underwent femoral shaft fracture fixation complicated by deep infection requiring debridement. The implants were removed 10 months later after long-term treatment with minocycline and fracture union. A refracture of the femoral shaft occurred 2 days after implant removal and repeat fixation was required. Intraoperatively, abundant heavily pigmented and dark brown bone callus was noted over the old fracture site. There was no evidence of other bony pathology and the appearance was consistent with minocycline-associated pigmentation. As far as we are aware, this is the first case of black bone disease affecting callus within the interval period of bone healing. We also discuss the relevant literature on black bone disease to bring light on this rare entity that is an unwelcomed surprise to operating orthopaedic surgeons. 2016 BMJ Publishing Group Ltd.

  10. Surgical treatment of intra-articular calcaneal fractures.

    PubMed

    Stapleton, John J; Zgonis, Thomas

    2014-10-01

    Most intra-articular calcaneal fractures are a result of high-energy trauma. The operative management of calcaneal fractures has been based on achieving anatomic reduction and minimizing complications of the compromised soft tissue envelope. The traditional extensile lateral approach offers advantages of achieving adequate fracture reduction with the risk of wound-healing complications and infection. Limited open reduction and internal fixation techniques with or without using external fixation focuses on achieving fracture reduction with less risk of wound complications but higher risk of malunion. This article discusses key points of operative management for various intra-articular calcaneal fracture patterns and clinical presentations. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Is fibular fracture displacement consistent with tibiotalar displacement?

    PubMed

    van den Bekerom, Michel P J; van Dijk, C Niek

    2010-04-01

    We believed open reduction with internal fixation is required for supination-external rotation ankle fractures located at the level of the distal tibiofibular syndesmosis (Lauge-Hanssen SER II and Weber B) with 2 mm or more fibular fracture displacement. The rationale for surgery for these ankle fractures is based on the notion of elevated intraarticular contact pressures with lateral displacement. To diagnose these injuries, we presumed that in patients with a fibular fracture with at least 2 mm fracture displacement, the lateral malleolus and talus have moved at least 2 mm in a lateral direction without medial displacement of the proximal fibula. We reviewed 55 adult patients treated operatively for a supination-external rotation II ankle fracture (2 mm or more fibular fracture displacement) between 1990 and 1998. On standard radiographs, distance from the tibia to the proximal fibula, distance from the tibia to the distal fibula, and displacement at the level of the fibular fracture were measured. These distances were compared preoperatively and postoperatively. We concluded tibiotalar displacement cannot be reliably assessed at the level of the fracture. Based on this and other studies, we believe there is little evidence to perform open reduction and internal fixation of supination-external rotation II ankle fractures. Level IV, case series. See Guidelines for Authors for a complete description of levels of evidence.

  12. Infected nonunion of tibia

    PubMed Central

    Chaudhary, Milind Madhav

    2017-01-01

    Infected nonunions of tibia pose many challenges to the treating surgeon and the patient. Challenges include recalcitrant infection, complex deformities, sclerotic bone ends, large bone gaps, shortening, and joint stiffness. They are easy to diagnose and difficult to treat. The ASAMI classification helps decide treatment. The nonunion severity score proposed by Calori measures many parameters to give a prognosis. The infection severity score uses simple clinical signs to grade severity of infection. This determines number of surgeries and allows choice of hardware, either external or internal for definitive treatment. Co-morbid factors such as smoking, diabetes, nonsteroidal anti-inflammatory drug use, and hypovitaminosis D influence the choice and duration of treatment. Thorough debridement is the mainstay of treatment. Removal of all necrotic bone and soft tissue is needed. Care is exercised in shaping bone ends. Internal fixation can help achieve union if infection was mild. Severe infections need external fixation use in a second stage. Compression at nonunion site achieves union. It can be combined with a corticotomy lengthening at a distant site for equalization. Soft tissue deficit has to be covered by flaps, either local or microvascular. Bone gaps are best filled with the reliable technique of bone transport. Regenerate bone may be formed proximally, distally, or at both sites. Acute compression can fill bone gaps and may need a fibular resection. Gradual reduction of bone gap happens with bone transport, without need for fibulectomy. When bone ends dock, union may be achieved by vertical or horizontal compression. Biological stimulus from iliac crest bone grafts, bone marrow aspirate injections, and platelet concentrates hasten union. Bone graft substitutes add volume to graft and help fill defects. Addition of rh-BMP-7 may help in healing albeit at a much higher cost. Regeneration may need stimulation and augmentation. Induced membrane technique is an alternative to bone transport to fill gaps. It needs large amounts of bone graft from iliac crest or femoral canal. This is an expensive method physiologically and economically. Infection can resorb the graft and cause failure of treatment. It can be done in select cases after thorough eradication of infection. Patience and perseverance are needed for successful resolution of infection and achieving union. PMID:28566776

  13. Knee arthrodesis using a customised modular intramedullary nail in failed infected total knee arthroplasty.

    PubMed

    Putman, S; Kern, G; Senneville, E; Beltrand, E; Migaud, H

    2013-06-01

    Knee arthrodesis is used to treat patients with failed infected total knee arthroplasty (TKA). Among fixation methods, intramedullary nailing increases the chances of bone union but may carry a risk of infection around the nail. This risk is not well understood, because available case-series studies were not confined to patients with knee infection. Infection recurrence rates after knee arthrodesis with intramedullary nailing used to treat failed infected TKA are similar to those seen with other fixation methods. We retrospectively reviewed 31 cases of knee arthrodesis with fixation by a modular intramedullary nail performed at a subspecialized center treating complex osteoarticular infections (CRIOAC). The antibiotic regimen was determined based on multidisciplinary discussions and microbiological studies of preoperative and intraoperative specimens. Mean follow-up was 50 ± 22 months (range, 28-90 months). Arthrodesis was performed in one stage (n=6) or two stages (n=25). Success was defined as presence, after a postoperative follow-up of at least 24 months, based on the following criteria: normal erythrocyte sedimentation rate and/or C-reactive protein, no wound inflammation or sinus tract, no revision surgery, and no antibiotic treatment. Bone union was not a criterion for a successful arthrodesis procedure. Removal of the fixation material was required in three patients and long-term palliative antibiotic therapy in three patients (fixation material in place with repeated positive specimens) for a total of six failures due to infection (6/31, 19.4%). None of the patients experienced mechanical failure (no breakage of the material and no fixation failure of the nails designed to allow osteointegration). The mean leg length discrepancy was 10 ± 10 mm (range, 5-34 mm) and the mean Oxford score was 41 ± 11 (range, 23-58). The 50-month rate of arthrodesis survival to revision surgery for nail removal was 77.8 ± 4% and the 50-month rate of arthrodesis survival without revision surgery for persistent infection was 74.6 ± 4.2%. The infection recurrence rate was higher than with other fixation methods but remained acceptable (19.4%). Use of a modular intramedullary nail prevented major leg-length discrepancies, which are often poorly accepted by the patients, and allowed immediate weight bearing despite the often severe bone loss. Level IV, retrospective cohort study. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  14. Modified preauricular approach and rigid internal fixation for intracapsular condyle fracture of the mandible.

    PubMed

    He, Dongmei; Yang, Chi; Chen, Minjie; Bin, Jiang; Zhang, Xiaohu; Qiu, Yating

    2010-07-01

    This article reports a modified preauricular approach for intracapsular condyle fracture (ICF) of the mandible and evaluates the stability of various internal fixation methods in the temporomandibular joint (TMJ) division of the Shanghai Ninth People's Hospital. One hundred fifty-one patients with 208 ICFs diagnosed by panoramic radiograph and computed tomographic (CT) scan received open treatment in the TMJ division from 1999 to 2008. Their charts were reviewed. Classification of the fracture was based on coronal CT scan. Forty-three patients also underwent magnetic resonance imaging before the operation to check displacement of the disc. A modified preauricular approach was used for all patients. Various internal fixation methods from wire, to screw, to plate were evaluated for stability. There were 110 ICFs of type A fracture, 60 of type B fracture, 9 of type C fracture, 25 of type M fracture, and 4 fractures without displacement. A modified preauricular approach was used for open treatment, which can better expose and protect the TMJ and superficial temporal vessels. Wire and plate is the commonly used stable fixation method for type A, B, and M fractures, which accounted for 56.7% (101/178). Small fracture fragments were removed with disc repositioning for all type C fractures (n = 9) and some type B (n = 9) and M fractures (n = 5). Three type M fracture and 3 nondisplaced ICFs were treated closed. Eighty-nine patients with 115 ICFs had postoperative CT scan, which showed anatomic and nearly anatomic fracture reduction rates of 95.6%. Thirty-five patients with 44 ICFs had long-term follow-ups from 3 months to 5 years. Among them, 63.2% (n = 12/19) pediatric ICFs had continuous condyle growth after open reduction and rigid fixation; 92% adults had ICFs that healed well (n = 23/25). Postoperative complications were facial nerve injury (n = 3), TMJ clicking (n = 1), and condyle resorption that required plate removal (n = 4). A modified preauricular approach provides better exposure and protection of the TMJ and superficial temporal vessels. Wire and plate provides stable fixation for type A and some type B and M fractures. Open reduction and rigid fixation produce good results for adult patients. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Evaluating the Long-Term Stability of Metals Precipitated In-Situ

    EPA Science Inventory

    Because metals (including metals and metalloids) cannot be destroyed, unlike organic contaminants, in-situ approaches for their removal from groundwater necessarily involves fixation/immobilization in the solid aquifer matrix. Consequently, the success of precipitation based in...

  16. A 5-year experience with a minimally invasive technique for pectus carinatum repair.

    PubMed

    Abramson, Horacio; D'Agostino, José; Wuscovi, Sebastián

    2009-01-01

    This report describes a 5-year experience with a novel, minimally invasive surgical technique for treatment of pectus carinatum. From June 2002 to August 2007, 40 patients underwent operation to correct pectus carinatum by pressure applied through a curved steel bar that was placed subcutaneously anterior to the sternum, via lateral thoracic incisions. The bar is inserted through a polyvinyl chloride tube with the convexity facing posteriorly. The polyvinyl chloride tube is positioned presternally by trocar. Subperiosteal wires attach small fixation plates to the ribs laterally, and the convex bar is secured to the small fixation plates with screws applying manual pressure to the anterior chest wall until the desired configuration is achieved. The compressive elongated bar is attached to the fixation plate with screws. The average age was 14.3 years (range, 10-21 years), and 90% were male. Both symmetric and asymmetric protrusions were treated. Patients whose chest was not malleable, and whose sternum could not be brought to a desirable position with pressure from the operator's hand, were treated by the open or "Ravitch" technique. After 2 or more years, the bar, wires stitches, screws, and fixation plates were removed. Of 40 patients treated with this procedure, 20 have undergone bar removal with the following results: 10 excellent, 4 good, 4 fair, and 2 poor. Average blood loss was 15 mL. Average length of hospital stay was as follows: implant, 3.8 days; removal, 1.4 days. Patients returned to routine activity 14 days after repair. Average follow-up since primary repair is 2.49 years. In those who have had bar removal, it is 1.53 years. Complications were pneumothorax in 1 patient, treated with chest tub e suction; skin adherence in 8 cases; seroma in 6; wire breakage in 3; persistence of pain in 1; and infection in 1. Technical modifications (selecting younger patients, excluding patients with a stiff thoracic wall, submuscular insertion of the bar, stronger pericostal wire) have been associated with no complications in the last 16 cases. This experience with a new, minimally invasive technique for the treatment of pectus carinatum shows it to be safe and effective. The correction obtained was highly satisfactory with minimal complications. It should be considered in appropriate cases as an alternative to more invasive techniques.

  17. CO2 Fixation, Lipid Production, and Power Generation by a Novel Air-Lift-Type Microbial Carbon Capture Cell System.

    PubMed

    Hu, Xia; Liu, Baojun; Zhou, Jiti; Jin, Ruofei; Qiao, Sen; Liu, Guangfei

    2015-09-01

    An air-lift-type microbial carbon capture cell (ALMCC) was constructed for the first time by using an air-lift-type photobioreactor as the cathode chamber. The performance of ALMCC in fixing high concentration of CO2, producing energy (power and biodiesel), and removing COD together with nutrients was investigated and compared with the traditional microbial carbon capture cell (MCC) and air-lift-type photobioreactor (ALP). The ALMCC system produced a maximum power density of 972.5 mW·m(-3) and removed 86.69% of COD, 70.52% of ammonium nitrogen, and 69.24% of phosphorus, which indicate that ALMCC performed better than MCC in terms of power generation and wastewater treatment efficiency. Besides, ALMCC demonstrated 9.98- and 1.88-fold increases over ALP and MCC in the CO2 fixation rate, respectively. Similarly, the ALMCC significantly presented a higher lipid productivity compared to those control reactors. More importantly, the preliminary analysis of energy balance suggested that the net energy of the ALMCC system was significantly superior to other systems and could theoretically produce enough energy to cover its consumption. In this work, the established ALMCC system simultaneously achieved the high level of CO2 fixation, energy recycle, and municipal wastewater treatment effectively and efficiently.

  18. Luteinizing hormone-releasing hormone (LHRH) in rat olfactory systems.

    PubMed

    Witkin, J W; Silverman, A J

    1983-08-20

    The luteinizing hormone-releasing hormone (LHRH) systems of rat olfactory bulbs and nasal areas were studied in neonatal and adult rats. Animals were perfused with Zamboni's fixative and olfactory bulbs with nasal olfactory areas intact were removed, postfixed, and decalcified. LHRH was immunohistochemically demonstrated in unembedded frozen or vibratome sections. Luteinizing hormone-releasing hormone immunoreactive elements were found along the course of the nervus terminalis (NT) and within both the main and accessory olfactory bulbs (MOB and AOB, respectively). Both LHRH neurons and fibers were present in the AOB, but only fibers were detected in the MOB. The fibers of the AOB were not confined to any particular lamina while fibers in the MOB were found mainly in the external plexiform layer. LHRH fibers were found in the mucosa of the olfactory epithelium of the vomeronasal organ in both neonatal and adult rats. The NT probably serves as a source of LHRH fibers for both the AOB and the MOB and for fibers observed in the olfactory epithelium of the vomeronasal organ. Other likely sources of LHRH fibers in the olfactory bulb are discussed.

  19. Intramedullary stabilization and over-nail lengthening as two-stage treatment of femoral nonunion with shortening. Case study.

    PubMed

    Kącki, Wojciech; Jasiewicz, Barbara; Radło, Paweł

    2014-01-01

    Nonunion is one of the most serious complications of long bone fractures. It may be accompanied by a shortening of the segment. The authors describe the case of a 21-year-old woman with a post-traumatic nonunion with shortening of the femur. Treatment was divided into two stages: first, a previously placed nail was removed and new intramedullary stabilization was carried out while bone defects were filled with a bone graft substitute and platelet rich plasma was administered. After the nonunion had healed, the femur was lengthened over an external fixator and an intramedullary nail, resulting in equality of limb length. After eight years of follow-up, the lower limbs remain equal with a properly aligned long axis of the lower limb operated on and a full range of motion in the joints. The treatment strategy described in our article may be an alternative to one-stage surgery if the patient does not consent to it or in the presence of contraindications, but it is associated with a longer treatment time and necessity of additional surgeries.

  20. [Analysis of reason and strategy for the failure of posterior pedicle screw short-segment internal fixation on thoracolumbar fractures].

    PubMed

    Xing, Jin-Ming; Peng, Wen-Ming; Shi, Chu-Yun; Xu, Lei; Pan, Qi-Huao

    2013-03-01

    To analyze the reason and strategy for failure of posterior pedicle screw short-segment internal fixation on thoracolumbar fractures. From March 2008 to December 2010,the clinical data of 18 patients with thoracolumbar fracture failed in posterior pedicle screw short-segment internal fixation were retrospectively analyzed. There were 11 males and 7 females with an average age of 37.2 years (ranged, 19 to 63). The time from the first operation to complication occurrence was from 6 to 44 months with an average of 14.3 months. Of them,fusion failure was in 7 cases (combined with screw breakage in 4 cases), the progressive neuro-dysfunction was in 5 cases,the progressive lumbodorsal pain was in 6 cases. All 18 patients with kyphosis were treated with anterior internal fixation remaining posterior fixation (9 cases) and anterior internal fixation after posterior fixation removal (9 cases). All the patients were followed up from 18 to 50 months with an average of 30.5 months. No intetnal fixation loosening and breakage were found, moreover, X-ray and lamellar CT showed bone healing well. Preoperative, postoperative at 3 months and at final follow-up, ODI score was respectively 31.6+/-5.1, 8.6+/-5.7, 8.3+/-3.2; VAS score was respectively 7.2+/-2.3, 2.3+/-0.7, 2.1+/-1.1; kyphosis angle was respectively (-21.2/-+7.8 degreeso, (-5.3+/-6.8 degrees ), (-5.8+/-7.8 )degrees. Compared with preoperative data ,above-listed items had obviously ameliorated(P<0.05). Treatment of thoracolumbar fracture with posterior pedicle screw short-segment internal fixation may result in the complications such as bone nonunion ,internal fixation breakage and progressive kyphosis. Anterior reconstruction may be a good strategy for the failure of posterior operation.

  1. Design and Optimization of Resorbable Silk Internal Fixation Devices

    NASA Astrophysics Data System (ADS)

    Haas, Dylan S.

    Limitations of current material options for internal fracture fixation devices have resulted in a large gap between user needs and hardware function. Metal systems offer robust mechanical strength and ease of implantation but require secondary surgery for removal and/or result in long-term complications (infection, palpability, sensitivity, etc.). Current resorbable devices eliminate the need for second surgery and long-term complications but are still associated with negative host response as well as limited functionality and more difficult implantation. There is a definitive need for orthopedic hardware that is mechanically capable of immediate fracture stabilization and fracture fixation during healing, can safely biodegrade while allowing complete bone remodeling, can be resterilized for reuse, and is easily implantable (self-tapping). Previous work investigated the use of silk protein to produce resorbable orthopedic hardware for non- load bearing fracture fixation. In this study, silk orthopedic hardware was further investigated and optimized in order to better understand the ability of silk as a fracture fixation system and more closely meet the unfulfilled market needs. Solvent-based and aqueous-based silk processing formulations were cross-linked with methanol to induce beta sheet structure, dried, autoclaved and then machined to the desired device/geometry. Silk hardware was evaluated for dry, hydrated and fatigued (cyclic) mechanical properties, in vitro degradation, resterilization, functionalization with osteoinductive molecules and implantation technique for fracture fixation. Mechanical strength showed minor improvements from previous results, but remains comparable to current resorbable fixation systems with the advantages of self-tapping ability for ease of implantation, full degradation in 10 months, ability to be resterilized and reused, and ability to release molecules for osteoinudction. In vivo assessment confirmed biocompatibility, showed improved bone deposition and remodeling with functionalization and showed promising feasibility of fracture fixations with minor adjustments to geometry. The proposed silk orthopedic hardware exhibits high potential as a resorbable fixation system that can bridge the gap between the current materials for internal fixation devices.

  2. [Surgical treatment of pronation and supination external rotation trimalleolar fractures].

    PubMed

    Xu, Ye-qing; Zhan, Bei-lei; He, Fei-xiong; Wei, Hong-da

    2008-04-01

    To explore the operative method and its clinical effects of pronation and supination external rotation trimalleolar fractures. From March 2000 to July 2006,42 patients of the pronation and supination external rotation trimalleolar fractures treated with open reduction and internal fixation. Thirty-one were males and 11 were females,with an average age of 40.5 years (from 19 to 76 years). Four cases were open fractures and 38 cases close fractures. The fractures were classified as pronation-external rotation (grade IV) injury in 18 cases and supination-external rotation (grade IV)in 24 cases according to the system of Lauge-Hansen. The time of injury to operation was 2 hours to 27 days. The medial, lateral and posterior malleolus were exposed by standard anteromedial and Gatellier-Chastang approaches. The reduction and internal fixation started with the posterior,then the medial and the lateral malleolus and distal tibiofibular syndesmosis in sequence. The anteroposterior, lateral and mostise X-ray films were taken after operation. All the patients were followed up for an average time of 13.5 months(from 6 to 24 months). The time of union was from 12 to 16 weeks. The results were excellent in 20,good in 16, fair in 4 and poor in 2 cases according to Baird-Jackson ankle scoring system based on pain, stability, walking ability,range of motion and radiological manifestations. The excellent and good rate was 85.7%. There were no infection,malunion and nonunion of the fractures except that the inserted screw to distal tibiofibular syndesmosis was broken in 1 case. The key of operative treatment is to restore the anatomy of ankle and to regain the ankle function maximally.

  3. Fixation of supraglenoid tubercle fractures using distal femoral locking plates in three Warmblood horses.

    PubMed

    Frei, Sina; Fürst, Anton E; Sacks, Murielle; Bischofberger, Andrea S

    2016-05-18

    Three horses that were presented with supraglenoid tubercle fractures were treated with open reduction and internal fixation using distal femoral locking plates (DFLP). Placing the DFLP caudal to the scapular spine in order to preserve the suprascapular nerve led to a stable fixation, however, it resulted in infraspinatus muscle atrophy and mild scapulohumeral joint instability (case 1). Placing the DFLP cranial to the scapular spine and under the suprascapular nerve resulted in a stable fixation, however, it resulted in severe atrophy of the supraspinatus and infraspinatus muscles and scapulohumeral joint instability (case 2). Placing the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage site resulted in the best outcome (case 3). Only a mild degree of supraspinatus and infraspinatus muscle atrophy was apparent, which resolved quickly and with no effect on scapulohumeral joint stability. In all cases, fixation of supraglenoid tubercle fractures using DFLP in slightly different techniques led to stable fixations with good long-term outcome. One case suffered from a mild incisional infection and plates were removed in two horses. Placement of the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage prevented major nerve damage. Further cases investigating the degree of muscle atrophy following the use of the DFLP placed in the above-described technique are justified to improve patient outcome.

  4. Corridors and some ecological and evolutionary consequences of connectivity.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orrock, John L

    2004-07-01

    Abstract - By connecting disjunct patches, corridors may offset the effects of fragmentation by promoting gene flow and population persistence. However, the ultimate effect of corridors on a focal species may hinge upon two considerations: how corridors may affect ecological interactions that impinge upon that species, and how corridors might affect the fixation of novel alleles that ultimately determine fitness and persistence. Using an experimental landscape, I show that corridor-mediated changes in patch shape change seed predation in connected and unconnected patches, and shift the behavior, abundance, and distribution of seed predators. Rodent seed predators removed more seeds in connectedmore » patches, arthropod seed predators removed more seeds in rectangular patches, and avian seed predation did not differ due to patch type. Rodent foraging was greater in the interior of connected patches because changes in patch shape influenced risk perceived by rodents while foraging. Ant communities were also affected by changes in patch shape caused by corridors, rather than corridor effects per se. The distribution and abundance of ants differed among edge-rich areas (corridors and wings), edges, and the patch interior. In rectangular patches, fire ants (Solenopsis spp.) had negative impacts on other ant species. By changing the activity of rodents, and the composition of ant communities, corridors may have important impacts on seeds. Bird-dispersed seeds may benefit from increased dispersal among connected patches, but connected patches also have greater predation risk. Using a simulation model, I demonstrate that gene flow between a stable population and a population that experiences local extinction or a reduction in size (e.g. due to natural or anthropogenic disturbance) can dramatically affect fixation of alleles in the stable population. Alone or in concert, frequent disturbance, high rates of movement, and low habitat quality make it more likely that connectivity-mediated fixation will promote fixation of harmful alleles and reduce fixation of beneficial alleles.« less

  5. The Effects of Different External Carbon Sources on Nitrous Oxide Emissions during Denitrification in Biological Nutrient Removal Processes

    NASA Astrophysics Data System (ADS)

    Hu, Xiang; Zhang, Jing; Hou, Hongxun

    2018-01-01

    The aim of this study was to investigate the effects of two different external carbon sources (acetate and ethanol) on the nitrous oxide (N2O) emissions during denitrification in biological nutrient removal processes. Results showed that external carbon source significantly influenced N2O emissions during the denitrification process. When acetate served as the external carbon source, 0.49 mg N/L and 0.85 mg N/L of N2O was produced during the denitrificaiton processes in anoxic and anaerobic/anoxic experiments, giving a ratio of N2O-N production to TN removal of 2.37% and 4.96%, respectively. Compared with acetate, the amount of N2O production is negligible when ethanol used as external carbon addition. This suggested that ethanol is a potential alternative external carbon source for acetate from the point of view of N2O emissions.

  6. Fracture reduction and primary ankle arthrodesis: a reliable approach for severely comminuted tibial pilon fracture.

    PubMed

    Beaman, Douglas N; Gellman, Richard

    2014-12-01

    Posttraumatic arthritis and prolonged recovery are typical after a severely comminuted tibial pilon fracture, and ankle arthrodesis is a common salvage procedure. However, few reports discuss the option of immediate arthrodesis, which may be a potentially viable approach to accelerate overall recovery in patients with severe fracture patterns. (1) How long does it take the fracture to heal and the arthrodesis to fuse when primary ankle arthrodesis is a component of initial fracture management? (2) How do these patients fare clinically in terms of modified American Orthopaedic Foot and Ankle Society (AOFAS) scores and activity levels after this treatment? (3) Does primary ankle arthrodesis heal in an acceptable position when anterior ankle arthrodesis plates are used? During a 2-year period, we performed open fracture reduction and internal fixation in 63 patients. Eleven patients (12 ankles) with severely comminuted high-energy tibial pilon fractures were retrospectively reviewed after surgical treatment with primary ankle arthrodesis and fracture reduction. Average patient age was 58 years, and minimum followup was 6 months (average, 14 months; range, 6-22 months). Anatomically designed anterior ankle arthrodesis plates were used in 10 ankles. Ring external fixation was used in nine ankles with concomitant tibia fracture or in instances requiring additional fixation. Clinical evaluation included chart review, interview, the AOFAS ankle-hindfoot score, and radiographic evaluation. All of the ankle arthrodeses healed at an average of 4.4 months (range, 3-5 months). One patient had a nonunion at the metaphyseal fracture, which healed with revision surgery. The average AOFAS ankle-hindfoot score was 83 with 88% having an excellent or good result. Radiographic and clinical analysis confirmed a plantigrade foot without malalignment. No patients required revision surgery for malunion. Primary ankle arthrodesis combined with fracture reduction for the severely comminuted tibial pilon fracture reliably healed and restored acceptable function in this highly selective patient group. Ring external fixation may be a useful adjunct to internal fixation, and this concept should be further studied. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  7. Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol.

    PubMed

    Raduan Neto, Jorge; de Moraes, Vinicius Ynoe; Gomes Dos Santos, João B; Faloppa, Flávio; Belloti, João Carlos

    2014-03-05

    Various treatments are available for reducible unstable fractures of the distal radius, such as closed reduction combined with fixation by external fixator (EF), and rigid internal fixation using a locked volar plate (VP). Although there are studies comparing these methods, there is no conclusive evidence indicating which treatment is best. The hypothesis of this study is that surgical treatment with a VP is more effective than EF from the standpoint of functional outcome (patient-reported). The study is randomized clinical trial with parallel groups and a blinded evaluator and involves the surgical interventions EF and VP. Patients will be randomly assigned (assignment ratio 1:1) using sealed opaque envelopes. This trial will include consecutive adult patients with an acute (up to 15 days) displaced, unstable fracture of the distal end of the radius of type A2, A3, C1, C2 or C3 by the Arbeitsgemeinschaft für Osteosynthesefragen-Association for the Study of Internal Fixation classification and type II or type III by the IDEAL32 classification, without previous surgical treatments of the wrist. The surgical intervention assigned will be performed by three surgical specialists familiar with the techniques described. Evaluations will be performed at 2, and 8 weeks, 3, 6 and 12 months, with the primary outcomes being measured by the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and measurement of pain (Visual Analog Pain Scale and digital algometer). Secondary outcomes will include radiographic parameters, objective functional evaluation (goniometry and dynamometry), and the rate of complications and method failure according to the intention-to-treat principle. Final postoperative evaluations (6 and 12 months) will be performed by independent blinded evaluators. For the Student's t-test, a difference of 10 points in the DASH score, with a 95% confidence interval, a statistical power of 80%, and 20% sampling error results in 36 patients per group. Results from this study protocol will improve the current evidence regarding to the surgical treatment these fractures. ISCRTN09599740.

  8. Incidence and risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture: A systematic review and meta-analysis.

    PubMed

    Shao, Jiashen; Chang, Hengrui; Zhu, Yanbin; Chen, Wei; Zheng, Zhanle; Zhang, Huixin; Zhang, Yingze

    2017-05-01

    This study aimed to quantitatively summarize the risk factors associated with surgical site infection after open reduction and internal fixation of tibial plateau fracture. Medline, Embase, CNKI, Wanfang database and Cochrane central database were searched for relevant original studies from database inception to October 2016. Eligible studies had to meet quality assessment criteria according to the Newcastle-Ottawa Scale, and had to evaluate the risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture. Stata 11.0 software was used for this meta-analysis. Eight studies involving 2214 cases of tibial plateau fracture treated by open reduction and internal fixation and 219 cases of surgical site infection were included in this meta-analysis. The following parameters were identified as significant risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture (p < 0.05): open fracture (OR 3.78; 95% CI 2.71-5.27), compartment syndrome (OR 3.53; 95% CI 2.13-5.86), operative time (OR 2.15; 95% CI 1.53-3.02), tobacco use (OR 2.13; 95% CI 1.13-3.99), and external fixation (OR 2.07; 95% CI 1.05-4.09). Other factors, including male sex, were not identified as risk factors for surgical site infection. Patients with the abovementioned medical conditions are at risk of surgical site infection after open reduction and internal fixation of tibial plateau fracture. Surgeons should be cognizant of these risks and give relevant preoperative advice. Copyright © 2017. Published by Elsevier Ltd.

  9. Bacterial N2-fixation in mangrove ecosystems: insights from a diazotroph-mangrove interaction.

    PubMed

    Alfaro-Espinoza, Gabriela; Ullrich, Matthias S

    2015-01-01

    Mangrove forests are highly productive ecosystems but represent low nutrient environments. Nitrogen availability is one of the main factors limiting mangrove growth. Diazotrophs have been identified as key organisms that provide nitrogen to these environments. N2-fixation by such organisms was found to be higher in the mangrove roots than in surrounding rhizosphere. Moreover, previous studies showed that mangroves grew better in the presence of N2-fixers indicating a potentially mutualistic relationship. However, the molecular signals and mechanisms that govern these interactions are still poorly understood. Here we present novel insights in the interaction of a diazotroph with a mangrove species to improve our understanding of the molecular and ecophysiological relationship between these two organisms under controlled conditions. Our results showed that Marinobacterium mangrovicola is a versatile organism capable of competing with other organisms to survive for long periods in mangrove soils. N2-fixation by this bacterium was up-regulated in the presence of mangrove roots, indicating a possible beneficial interaction. The increase in N2-fixation was limited to cells of the exponential growth phase suggesting that N2-fixation differs over the bacterial growth cycle. Bacterial transformants harboring a transcriptional nifH::gusA fusion showed that M. mangrovicola successfully colonized mangrove roots and simultaneously conducted N2-fixation. The colonization process was stimulated by the lack of an external carbon source suggesting a possible mutualistic relationship. M. mangrovicola represents an interesting genetically accessible diazotroph, which colonize mangrove roots and exhibit higher N2-fixation in the presence of mangrove roots. Consequently, we propose this microorganism as a tool to study molecular interactions between N2-fixers and mangrove plants and to better understand how changes in the environment could impact these important and relatively unknown interactions.

  10. Optimal Treatment of Malignant Long Bone Fracture: Influence of Method of Repair and External Beam Irradiation on the Pathway and Efficacy of Fracture Healing

    DTIC Science & Technology

    2015-10-01

    stiffness, or a partial snap with lower yield force and stiffness (Figure 4). Three dimensional micro CT analysis around fracture Figure 3. (a-b... fractures with plate fixation on both sides and irradiation on the left while the contralateral limb serves as a non-radiated internal control. The...AWARD NUMBER: W81XWH-13-1-0430 TITLE: Optimal Treatment of Malignant Long Bone Fracture : Influence of Method of Repair and External Beam

  11. Temporary Iliac Fixation to Salvage an Acute L4 Chance Fracture: Following Pedicle Screw Fixation for Adolescent Idiopathic Scoliosis.

    PubMed

    Kato, So; Lewis, Stephen J

    2017-03-01

    A case report. The aim of this study was to describe a technique of temporary distal fixation to the ilium to salvage an acute L4 fracture following a T3-L4 kyphoscoliosis correction. Pedicle fracture is a possible complication in pedicle screw fixation for scoliosis, which may lead to postoperative instability, resulting in loss of fixation and pseudoarthrosis. This report highlights the salvage treatment of a chance fracture that occurred in the lower instrumented vertebra following deformity correction for adolescent idiopathic scoliosis (AIS) without sacrificing further distal motion segments. A retrospective chart and radiograph review of a 13-year-old female who underwent surgical treatment for correction of AIS was performed. Following a T3-L4 correction with apical posterior column releases, an L4 Chance fracture with loss of distal fixation occurred on post-op day 3. Following an unsuccessful salvage with an infralaminar hook, a second revision was performed replacing the hook and adding bilateral temporary fixation to the ilium connected to the distal ends of the main rods through side-to-side connectors. The temporary fixation was removed 6 months later with successful healing of the fracture maintenance of the scoliosis correction at 2-year follow-up. Temporary extension of the construct to the ilium was successfully utilized in this case to salvage an acute L4 Chance fracture that occurred following a T3 to L4 construct for kyphoscoliosis. With this technique, successful reduction and healing of the fracture occurred with maintenance of the deformity correction without the need to fuse further distal segments. 4.

  12. Current Concepts in the Mandibular Condyle Fracture Management Part I: Overview of Condylar Fracture

    PubMed Central

    Yang, Jung-Dug; Chung, Ho-Yun; Cho, Byung-Chae

    2012-01-01

    The incidence of condylar fractures is high, but the management of fractures of the mandibular condyle continues to be controversial. Historically, maxillomandibular fixation, external fixation, and surgical splints with internal fixation systems were the techniques commonly used in the treatment of the fractured mandible. Condylar fractures can be extracapsular or intracapsular, undisplaced, deviated, displaced, or dislocated. Treatment depends on the age of the patient, the co-existence of other mandibular or maxillary fractures, whether the condylar fracture is unilateral or bilateral, the level and displacement of the fracture, the state of dentition and dental occlusion, and the surgeonnds on the age of the patient, the co-existence of othefrom which it is difficult to recover aesthetically and functionally;an appropriate treatment is required to reconstruct the shape and achieve the function ofthe uninjured status. To do this, accurate diagnosis, appropriate reduction and rigid fixation, and complication prevention are required. In particular, as mandibular condyle fracture may cause long-term complications such as malocclusion, particularly open bite, reduced posterior facial height, and facial asymmetry in addition to chronic pain and mobility limitation, great caution should be taken. Accordingly, the authors review a general overview of condyle fracture. PMID:22872830

  13. Cerclage wire and lag screw fixation of the lateral malleolus in supination and external rotation fractures of the ankle.

    PubMed

    Bajwa, Amarjit S; Gantz, D E

    2005-01-01

    Wound dehiscence and exposed lateral hardware can occur after open reduction internal fixation of lateral malleolus. The bulk of a lateral plate and the minimum soft tissue over the lateral malleolus may contribute to this situation. The objective of this study was to evaluate a series of patients with lateral malleolar fractures treated with operative reduction using minimal hardware. We wanted to observe whether there was any loss of reduction and whether there were any incidences of soft tissue disruption. Fifty-two patients with long spiral fracture of the lateral malleolus in a supination-external rotation injury were treated with two or three 3.5-mm lag screws inserted 1 cm apart and 1 or 2 circlage wires. Less rigid fixation was supplemented with a below-the-knee plaster cast. All patients were followed up until clinical and radiological evidence of fracture healing at 6, 10, and 14 weeks postoperatively. By 10 weeks, all patients were full weight bearing, although most patients still limped. At 14 weeks' follow-up, there were no infections or wound dehiscences. All patients were able to return to their activities of daily living. All the fractures had united without loss of original position. Two fractures of the posterior bone spikes seen during surgery united uneventfully. Long spiral fractures of the lateral malleolus of the ankle can be treated successfully with 2 or 3 lag screws and circlage wires without compromising the outcome of the fracture healing.

  14. Mechanical induction of critically delayed bone healing in sheep: radiological and biomechanical results.

    PubMed

    Schell, Hanna; Thompson, Mark S; Bail, Hermann J; Hoffmann, Jan-Erik; Schill, Alexander; Duda, Georg N; Lienau, Jasmin

    2008-10-20

    This study aimed to mechanically produce a standardized ovine model for a critically delayed bone union. A tibial osteotomy was stabilized with either a rigid (group I) or mechanically critical (group II) external fixator in sheep. Interfragmentary movements and ground reaction forces were monitored throughout the healing period of 9 weeks. After sacrifice at 6 weeks, 9 weeks and 6 months, radiographs were taken and the tibiae were examined mechanically. Interfragmentary movements were considerably larger in group II throughout the healing period. Unlike group I, the operated limb in group II did not return to full weight bearing during the treatment period. Radiographic and mechanical observations showed significantly inferior bone healing in group II at 6 and 9 weeks compared to group I. After 6 months, five sheep treated with the critical fixator showed radiological bridging of the osteotomy, but the biomechanical strength of the repair was still inferior to group I at 9 weeks. The remaining three animals had even developed a hypertrophic non-union. In this study, mechanical instability was employed to induce a critically delayed healing model in sheep. In some cases, this approach even led to the development of a hypertrophic non-union. The mechanical induction of critical bone healing using an external fixation device is a reasonable attempt to investigate the patho-physiological healing cascade without suffering from any biological intervention. Therefore, the presented ovine model provides the basis for a comparative evaluation of mechanisms controlling delayed and standard bone healing.

  15. [Analysis of tension-distraction state in the shin bones fractures in conditions of external fixation with application of apparatuses with different spatially oriented supports].

    PubMed

    Hutsuliak, V I

    2014-09-01

    In Autodesk Inventor 11 program, using method of end-capping elements, a three- dimensional computeric modelling of biomechanical systems of two models was conducted: I - "tibia - Ilizarov's apparatus with concentric location of supports"; II - "tibia - Ilizarov's apparatus with excentric location of supports". The loading, which was applied towards distal fragment in 6 standard degrees of freedom, was modelled for studying of the fixation rigidity of tibial fragments in these systems. Determination of the loading value in various directions, in which the fragment have had shifted by 1 mm, have constituted the main task of the investigation. In a model II a rigidity of the fragments fixation, in comparison with such in a model I, is bigger by 631.43% - while applying a compression loading, by 8.35 - 31.75% - the transversal one and by 19.72% - the rotation loading. While choosing the method of transosteal osteosynthesis of the shin bones the advantage, have the apparatuses with excentric location of supports, what secures the enhanced rigidity of the fragments fixation in comparison with such in apparatuses with concentric location of supports. Although, even in excentric location of supports in the apparatus the fixation rigidity is insufficient for early full loading of the traumatized extremity while walking. It is necessary to elaborate such apparatus, the form of which may be adopted toanatomic configuration of segment.

  16. Research on the Perforating Algorithm Based on STL Files

    NASA Astrophysics Data System (ADS)

    Yuchuan, Han; Xianfeng, Zhu; Yunrui, Bai; Zhiwen, Wu

    2018-04-01

    In the process of making medical personalized external fixation brace, the 3D data file should be perforated to increase the air permeability and reduce the weight. In this paper, a perforating algorithm for 3D STL file is proposed, which can perforate holes, hollow characters and engrave decorative patterns on STL files. The perforating process is composed of three steps. Firstly, make the imaginary space surface intersect with the STL model, and reconstruct triangles at the intersection. Secondly, delete the triangular facets inside the space surface and make a hole on the STL model. Thirdly, triangulate the inner surface of the hole, and thus realize the perforating. Choose the simple space equations such as cylindrical and rectangular prism equations as perforating equations can perforate round holes and rectangular holes. Through the combination of different holes, lettering, perforating decorative patterns and other perforated results can be accomplished. At last, an external fixation brace and an individual pen container were perforated holes using the algorithm, and the expected results were reached, which proved the algorithm is feasible.

  17. Contributing risk factors for orthopedic device related infections in sina hospital, tehran, iran.

    PubMed

    Hadadi, A; Zehtab, M J; Babagolzadeh, H; Ashraf, H

    2011-02-01

    In spite of decreasing incidence of orthopedic device-related infections to 1%, nowadays, device-related infection still remains a diagnostic, therapeutic and cost-related problem. The objective of this study is to evaluate the contributing risk factors for orthopedic device-related infections in Sina Hospital, Tehran, Iran. Three hundred and thirty patients who underwent orthopedic device implantation from 2002-2006 were enrolled; among them, 110 patients were complicated with infection. Descriptive and logistic regression analyses were performed to determine the risk factors for device related infections. Patients with infection were older compared to those without infection. The Staphylococcus aureus was the commonest organism. A correlation was observed between wound infection and external fixation, an underlying health condition, and addiction which were independent risk factors for a device related infection. Orthopedic device-related infection puts a great financial burden on patients and hospital resources and could lead to morbidity and mortality in patients. So, appropriate pre and postoperative wound care for dirty wounds, especially when external fixators are used, and in patients with poor conditions or addiction should be done with more caution.

  18. Novel Antibacterial Coating on Orthopedic Wires To Eliminate Pin Tract Infections

    PubMed Central

    Gil, Dmitry; Shuvaev, Sergey; Frank-Kamenetskii, Anastasia; Reukov, Vladimir; Gross, Christopher

    2017-01-01

    ABSTRACT Novel approaches to the prevention of microbial infections after the insertion of orthopedic external fixators are in great demand because of the extremely high incidence rates of such infections, which can reach up to 100% with longer implant residence times. Monolaurin is an antimicrobial agent with a known safety record that is broadly used in the food and cosmetic industries; however, its use in antimicrobial coatings of medical devices has not been studied in much detail. Here, we report the use of monolaurin as an antibacterial coating on external fixators for the first time. Monolaurin-coated Kirschner wires (K-wires) showed excellent antibacterial properties against three different bacterial strains, i.e., methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant Staphylococcus aureus (MRSA), and Staphylococcus epidermidis. Approximately 6.0-log reductions of both planktonic and adherent bacteria were achieved using monolaurin-coated K-wires, but monolaurin-coated K-wires did not show any observable cytotoxicity with mouse osteoblast cell cultures. Overall, monolaurin-coated K-wires could be promising as potent antimicrobial materials for orthopedic surgery. PMID:28483964

  19. [Damage control resuscitation of severe multiple trauma in the pelvic fractures].

    PubMed

    Fu, Chang-guo

    2015-05-01

    To discuss the clinical effects of damage control resuscitation (DCR) in treating severe multiple trauma in the pelvic fractures. From March 2009 to September 2013, a restrospective analysis was conducted on the clinical data of 28 patients with multiple trauma in the pelvic fractures, including 19 males and 9 females, ranging in age from 21 to 51 years old with an average of 32.5 years old. According to Tile classification of pelvic fractures, 16 cases were type B and 12 cases were type C. Injury severity score (ISS) averaged 32.0±3.4. All cases were treated with damage contral orthopaedics and DCR strategy, namely that used immediately with small capacity of balanced salt solution on admission so as to maintain the blood pressure between 80 to 90 mmHg. At the same time, emergency phase I simple debridement plus external fixator or bundled with fixed pelvic was done, and the chest or abdomen combined injury was treated at first. And limbs fracture was temporary dealing with bone traction or plaster external fixation, etc. After bleeding was controlled by operation, fluid resuscitation was done as fast as possible and the plasma was transfused early according to the proportion of plasma and red cell suspension (2 U:1 U-3 U:2 U). Dosage of balanced salt solution and blood before remedy shock was recorded, and the removal of time of lactic acid and coagulation were observed. Five cases were died after 4 to 15 hours into hospital (3 cases died for severe trauma-hemorrhagic shock and 2 cases for acute respiratory distress syndrome). Twenty-three cases were remedy shock at 1.6 to 4.3 hours after injury with an average of 2.4 hours. Period I operation duration was (78.2±10.3) minutes. Dosage of balanced salt solution was (3,798±340) ml and red cell suspension was 14 to 18 U, fresh frozen plasma (FFP) was (1,267±58) ml (1U FFP=100 ml), blood platelet was 8 to 12 U for 9 patients. The removal time of lactic acid and PT-APTT was (11.4±2.1) hours and (4.3±0.8) hours. Measures were taken to correct electrolyte and acid-base imbalance was normal. The success rat of recovery was 82.2% (23/28). Damage control resuscitation (DCR) integrates the main links such as damage control operation and allowable low blood pressure (or limited liquid resuscitation) and hemostatic control resuscitation, was early effective treatment measures for the patients with severe multiple trauma in the pelvic fractures.

  20. Pectoralis Major Repair With Unicortical Button Fixation And Suture Tape.

    PubMed

    Sanchez, Anthony; Ferrari, Marcio B; Frangiamore, Salvatore J; Sanchez, George; Kruckeberg, Bradley M; Provencher, Matthew T

    2017-06-01

    Although injuries of the pectoralis major muscle are generally uncommon, ruptures of the pectoralis major are occasionally seen in younger, more active patients who participate in weightlifting activities. These injuries usually occur during maximal contraction of the muscle, while in extension and external rotation. In the case of a rupture, operative treatment is advocated especially in young, active patients regardless of the chronicity of the injury. Various surgical techniques for reattachment of the avulsed tendon have been described, but bone tunnel and suture anchor repair techniques are most widely used. In this Technical Note, we present our preferred technique for acute pectoralis major rupture repair involving use of cortical buttons for tendon stump-to-bone fixation.

Top