Fayad, Hadi; Pan, Tinsu; Clément, Jean-François; Visvikis, Dimitris
2011-01-01
Purpose Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signals over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the entire patient external surface in real time. The main objective of this study was to assess the motion correlation between such an external patient surface and internal anatomical landmarks motion. Methods Four dimensional Computed Tomography (4D CT) volumes for ten patients were used in this study. Anatomical landmarks were manually selected in the thoracic region across the 4D CT datasets by two experts. The landmarks included normal structures as well as the tumour location. In addition, a distance map representing the entire external patient surface, which corresponds to surfaces acquired by a Time of Flight (ToF) camera or similar devices, was created by segmenting the skin of all 4D CT volumes using a thresholding algorithm. Finally, the correlation between the internal landmarks and external surface motion was evaluated for different regions (placement and size) throughout a patient’s surface. Results Significant variability was observed in the motion of the different parts of the external patient surface. The larger motion magnitude was consistently measured in the central regions of the abdominal and the thoracic areas for the different patient datasets considered. The highest correlation coefficients were observed between the motion of these external surface areas and internal landmarks such as the diaphragm and mediastinum structures as well as the tumour location landmarks (0.8 ± 0.18 and 0.72 ± 0.12 for the abdominal and the thoracic regions respectively). Worse correlation was observed when one considered landmarks not significantly influenced by respiratory motion such as the apex and the sternum. Discussion and conclusions There were large differences in the motion correlation observed considering different regions of interest placed over a patients’ external surface and internal anatomical landmarks. The positioning of current devices used for respiratory motion synchronization may reduce such correlation by averaging the motion over correlated and poorly correlated external regions. The potential of capturing in real-time the motion of the complete external patient surface as well as choosing the area of the surface that correlates best with the internal motion should allow reducing such variability and associated errors in both respiratory motion synchronization and subsequent motion modeling processes. PMID:21815390
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, S; Charpentier, P; Sayler, E
2015-06-15
Purpose Isocenter shifts and rotations to correct patient setup errors and organ motion cannot remedy some shape changes of large targets. We are investigating new methods in quantification of target deformation for realtime IGRT of breast and chest wall cancer. Methods Ninety-five patients of breast or chest wall cancer were accrued in an IRB-approved clinical trial of IGRT using 3D surface images acquired at daily setup and beam-on time via an in-room camera. Shifts and rotations relating to the planned reference surface were determined using iterative-closest-point alignment. Local surface displacements and target deformation are measured via a ray-surface intersection andmore » principal component analysis (PCA) of external surface, respectively. Isocenter shift, upper-abdominal displacement, and vectors of the surface projected onto the two principal components, PC1 and PC2, were evaluated for sensitivity and accuracy in detection of target deformation. Setup errors for some deformed targets were estimated by superlatively registering target volume, inner surface, or external surface in weekly CBCT or these outlines on weekly EPI. Results Setup difference according to the inner-surface, external surface, or target volume could be 1.5 cm. Video surface-guided setup agreed with EPI results to within < 0.5 cm while CBCT results were sometimes (∼20%) different from that of EPI (>0.5 cm) due to target deformation for some large breasts and some chest walls undergoing deep-breath-hold irradiation. Square root of PC1 and PC2 is very sensitive to external surface deformation and irregular breathing. Conclusion PCA of external surfaces is quick and simple way to detect target deformation in IGRT of breast and chest wall cancer. Setup corrections based on the target volume, inner surface, and external surface could be significant different. Thus, checking of target shape changes is essential for accurate image-guided patient setup and motion tracking of large deformable targets. NIH grant for the first author as cionsultant and the last author as the PI.« less
Cheshire, James; Gardner, Adrian; Berryman, Fiona; Pynsent, Paul
2017-01-01
Patient-reported outcomes are becoming increasingly recognised in the management of patients with adolescent idiopathic scoliosis (AIS). Integrated Shape Imaging System 2 (ISIS2) surface topography is a validated tool to assess AIS. Previous studies have failed to demonstrate strong correlations between AIS and patient-reported outcomes highlighting the need for additional objective surface parameters to define the deformities associated with AIS. The aim of this study was to examine whether the Scoliosis Research Society-22 (SRS-22) outcome questionnaire reflects the degree of measurable external asymmetry of the back in AIS and thus is a measure of patient outcome for external appearance. A total of 102 pre-operative AIS patients were identified retrospectively. Objective parameters were measured using ISIS2 surface topography. The associations between these parameters and the self-image and mental health domains of the SRS-22 questionnaire were investigated using correlation coefficients. All correlations between the parameters of asymmetry and SRS-22 self-image score were of weak strength. Similarly, all correlations between the parameters of asymmetry and SRS-22 mental health score were of weak strength. The SRS-22 mental health and self-image domains correlate poorly with external measures of deformity. This demonstrates that the assessment of mental health and self-image by the SRS-22 has little to do with external torso shape. Whilst the SRS-22 assesses the patient as a whole, it provides little information about objective measures of deformity over which a surgeon has control.
Jazaeri, Seyede Zohreh; Azad, Akram; Mehdizadeh, Hajar; Habibi, Seyed Amirhassan; Mandehgary Najafabadi, Mahbubeh; Saberi, Zakieh Sadat; Rahimzadegan, Hawre; Moradi, Saeed; Behzadipour, Saeed; Parnianpour, Mohamad; Khalaf, Kinda
2018-01-01
Background Although anxiety is a common non-motor outcome of Parkinson's disease (PD) affecting 40% of patients, little attention has been paid so far to its effects on balance impairment and postural control. Improvement of postural control through focusing on the environment (i.e. external focus) has been reported, but the role of anxiety, as a confounding variable, remains unclear. Objectives This study aimed to investigate the influence of anxiety and attentional focus instruction on the standing postural control of PD patients. Methods Thirty-four patients with PD (17 with high anxiety (HA-PD) and 17 with low anxiety (LA-PD)), as well as 17 gender- and age-matched healthy control subjects (HC) participated in the study. Postural control was evaluated using a combination of two levels of postural difficulty (standing on a rigid force plate surface with open eyes (RO) and standing on a foam surface with open eyes (FO)), as well as three attentional focus instructions (internal, external and no focus). Results Only the HA-PD group demonstrated significant postural control impairment as compared to the control, as indicated by significantly greater postural sway measures. Moreover, external focus significantly reduced postural sway in all participants especially during the FO condition. Conclusion The results of the current study provide evidence that anxiety influences balance control and postural stability in patients with PD, particularly those with high levels of anxiety. The results also confirmed that external focus is a potential strategy that significantly improves the postural control of these patients. Further investigation of clinical applicability is warranted towards developing effective therapeutic and rehabilitative treatment plans. PMID:29390029
Vasiliadis, Elias S; Grivas, Theodoros B; Psarakis, Spyridon A; Papavasileiou, Evangelos; Kaspiris, Angelos; Triantafyllopoulos, Georgios
2009-01-01
Background Treatment of distal tibial intra-articular fractures is challenging due to the difficulties in achieving anatomical reduction of the articular surface and the instability which may occur due to ligamentous and soft tissue injury. The purpose of this study is to present an algorithm in the application of external fixation in the management of intra-articular fractures of the distal tibia either from axial compression or from torsional forces. Materials and methods Thirty two patients with intra-articular fractures of the distal tibia have been studied. Based on the mechanism of injury they were divided into two groups. Group I includes 17 fractures due to axial compression and group II 15 fractures due to torsional force. An Ilizarov external fixation was used in 15 patients (11 of group I and 4 of group II). In 17 cases (6 of group I and 11 of group II) a unilateral hinged external fixator was used. In 7 out of 17 fractures of group I an additional fixation of the fibula was performed. Results All fractures were healed. The mean time of removal of the external fixator was 11 weeks for group I and 10 weeks for group II. In group I, 5 patients had radiological osteoarthritic lesions (grade III and IV) but only 2 were symptomatic. Delayed union occurred in 3 patients of group I with fixed fibula. Other complications included one patient of group II with subluxation of the ankle joint after removal of the hinged external fixator, in 2 patients reduction found to be insufficient during the postoperative follow up and were revised and 6 patients had a residual pain. The range of ankle joint motion was larger in group II. Conclusion Intra-articular fractures of the distal tibia due to axial compression are usually complicated with cartilaginous problems and are requiring anatomical reduction of the articular surface. Fractures due to torsional forces are complicated with ankle instability and reduction should be augmented with ligament repair, in order to restore normal movement of talus against the mortise. Both Ilizarov and hinged external fixators are unable to restore ligamentous stability. External fixation is recommended only for fractures of the ankle joint caused by axial compression because it is biomechanically superior and has a lower complication rate. PMID:19754962
The study of the dynamics of erythrocytes under the influence of an external electric field
NASA Astrophysics Data System (ADS)
Mamaeva, Sargylana N.; Maksimov, Georgy V.; Antonov, Stepan R.
2017-11-01
A mathematical model is considered for the determination of the surface charge of an erythrocyte with its shape approximated by a surface of revolution of the second order, and the investigation of the dynamics of erythrocytes under the influence of an external electric field. In the first part of this work, the electrical surface charge of the erythrocyte of the patient was calculated with the assumption that the change in the shape and size of the red blood cells leads to stabilization of the electric field, providing a normal electrostatic repulsion. In the second part of the work, the research results of dynamics of changes in the morphology of erythrocytes under the influence of an external electric field depending on the values of their surface charge and resistance of blood plasma is presented. In the course of the work, the dependence of the surface charge of red blood cells from their shape and size is presented. The determination of the relationship between the value of the charge field and the surface of erythrocytes in norm and in pathology is shown. The dependence of the velocity of the erythrocytes on the characteristics of the external electric field, surface charge of the erythrocyte and properties of the medium is obtained. The results of this study can be applied indirectly to diagnose diseases and to develop recommendations for experimental studies of hemodynamics under the influence of various external physical factors.
Yoon, Jihyung; Xie, Yibo; Zhang, Rui
2018-03-01
The purpose of this study was to evaluate a methodology to reduce scatter and leakage radiations to patients' surface and shallow depths during conventional and advanced external beam radiotherapy. Superflab boluses of different thicknesses were placed on top of a stack of solid water phantoms, and the bolus effect on surface and shallow depth doses for both open and intensity-modulated radiotherapy (IMRT) beams was evaluated using thermoluminescent dosimeters and ion chamber measurements. Contralateral breast dose reduction caused by the bolus was evaluated by delivering clinical postmastectomy radiotherapy (PMRT) plans to an anthropomorphic phantom. For the solid water phantom measurements, surface dose reduction caused by the Superflab bolus was achieved only in out-of-field area and on the incident side of the beam, and the dose reduction increased with bolus thickness. The dose reduction caused by the bolus was more significant at closer distances from the beam. Most of the dose reductions occurred in the first 2-cm depth and stopped at 4-cm depth. For clinical PMRT treatment plans, surface dose reductions using a 1-cm Superflab bolus were up to 31% and 62% for volumetric-modulated arc therapy and 4-field IMRT, respectively, but there was no dose reduction for Tomotherapy. A Superflab bolus can be used to reduce surface and shallow depth doses during external beam radiotherapy when it is placed out of the beam and on the incident side of the beam. Although we only validated this dose reduction strategy for PMRT treatments, it is applicable to any external beam radiotherapy and can potentially reduce patients' risk of developing radiation-induced side effects. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Torshabi, Ahmad Esmaili; Nankali, Saber
2016-01-01
In external beam radiotherapy, one of the most common and reliable methods for patient geometrical setup and/or predicting the tumor location is use of external markers. In this study, the main challenging issue is increasing the accuracy of patient setup by investigating external markers location. Since the location of each external marker may yield different patient setup accuracy, it is important to assess different locations of external markers using appropriate selective algorithms. To do this, two commercially available algorithms entitled a) canonical correlation analysis (CCA) and b) principal component analysis (PCA) were proposed as input selection algorithms. They work on the basis of maximum correlation coefficient and minimum variance between given datasets. The proposed input selection algorithms work in combination with an adaptive neuro‐fuzzy inference system (ANFIS) as a correlation model to give patient positioning information as output. Our proposed algorithms provide input file of ANFIS correlation model accurately. The required dataset for this study was prepared by means of a NURBS‐based 4D XCAT anthropomorphic phantom that can model the shape and structure of complex organs in human body along with motion information of dynamic organs. Moreover, a database of four real patients undergoing radiation therapy for lung cancers was utilized in this study for validation of proposed strategy. Final analyzed results demonstrate that input selection algorithms can reasonably select specific external markers from those areas of the thorax region where root mean square error (RMSE) of ANFIS model has minimum values at that given area. It is also found that the selected marker locations lie closely in those areas where surface point motion has a large amplitude and a high correlation. PACS number(s): 87.55.km, 87.55.N PMID:27929479
Sun, Tao
2016-01-01
Introduction Using network meta-analysis, we evaluated the adverse effects of the seven most common treatment methods, i.e., bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating, by their associated risk of developing complex regional pain syndrome (CRPS) in distal radius fracture (DRF) patients. Material and methods Following an exhaustive search of scientific literature databases for high quality studies, randomized controlled trials (RCTs) related to our study topic were screened and selected based on stringent predefined inclusion and exclusion criteria. Data extracted from the selected studies were used for statistical analyses using Stata 12.0 software. Results A total of 17 RCTs, including 1658 DRF patients, were enrolled in this network meta-analysis. Among the 1658 DRF patients, 452 received bridging external fixation, 525 received non-bridging external fixation, 154 received K-wire fixation, 84 received plaster fixation, 132 received dorsal plating, 123 received volar plating, and 188 received dorsal and volar plating. When compared to bridging external fixation patients, there was no marked difference in the CRPS risk in DRF patients receiving different treatments (all p > 0.05). However, the surface under the cumulative ranking curves (SUCRA) for plaster fixation (77.0%) and non-bridging external fixation (71.3%) were significantly higher compared with the other five methods. Conclusions Our findings suggest that compared with bridging external fixation, K-wire fixation, dorsal plating, volar plating, dorsal and volar plating, plaster fixation and non-bridging external fixation might be the better treatment methods to reduce the risk of CRPS in DRF patients. PMID:28144268
Collision prediction software for radiotherapy treatments.
Padilla, Laura; Pearson, Erik A; Pelizzari, Charles A
2015-11-01
This work presents a method of collision predictions for external beam radiotherapy using surface imaging. The present methodology focuses on collision prediction during treatment simulation to evaluate the clearance of a patient's treatment position and allow for its modification if necessary. A Kinect camera (Microsoft, Redmond, WA) is used to scan the patient and immobilization devices in the treatment position at the simulator. The surface is reconstructed using the skanect software (Occipital, Inc., San Francisco, CA). The treatment isocenter is marked using simulated orthogonal lasers projected on the surface scan. The point cloud of this surface is then shifted to isocenter and converted from Cartesian to cylindrical coordinates. A slab models the treatment couch. A cylinder with a radius equal to the normal distance from isocenter to the collimator plate, and a height defined by the collimator diameter is used to estimate collisions. Points within the cylinder clear through a full gantry rotation with the treatment couch at 0°, while points outside of it collide. The angles of collision are reported. This methodology was experimentally verified using a mannequin positioned in an alpha cradle with both arms up. A planning CT scan of the mannequin was performed, two isocenters were marked in pinnacle, and this information was exported to AlignRT (VisionRT, London, UK)--a surface imaging system for patient positioning. This was used to ensure accurate positioning of the mannequin in the treatment room, when available. Collision calculations were performed for the two treatment isocenters and the results compared to the collisions detected the room. The accuracy of the Kinect-Skanect surface was evaluated by comparing it to the external surface of the planning CT scan. Experimental verification results showed that the predicted angles of collision matched those recorded in the room within 0.5°, in most cases (largest deviation -1.2°). The accuracy study for the Kinect-Skanect surface showed an average discrepancy between the CT external contour and the surface scan of 2.2 mm. This methodology provides fast and reliable collision predictions using surface imaging. The use of the Kinect-Skanect system allows for a comprehensive modeling of the patient topography including all the relevant anatomy and immobilization devices that may lead to collisions. The use of this tool at the treatment simulation stage may allow therapists to evaluate the clearance of a patient's treatment position and optimize it before the planning CT scan is performed. This can allow for safer treatments for the patients due to better collision predictions and improved clinical workflow by minimizing replanning and resimulations due to unforeseen clearance issues.
Multimodal image registration of the scoliotic torso for surgical planning
2013-01-01
Background This paper presents a method that registers MRIs acquired in prone position, with surface topography (TP) and X-ray reconstructions acquired in standing position, in order to obtain a 3D representation of a human torso incorporating the external surface, bone structures, and soft tissues. Methods TP and X-ray data are registered using landmarks. Bone structures are used to register each MRI slice using an articulated model, and the soft tissue is confined to the volume delimited by the trunk and bone surfaces using a constrained thin-plate spline. Results The method is tested on 3 pre-surgical patients with scoliosis and shows a significant improvement, qualitatively and using the Dice similarity coefficient, in fitting the MRI into the standing patient model when compared to rigid and articulated model registration. The determinant of the Jacobian of the registration deformation shows higher variations in the deformation in areas closer to the surface of the torso. Conclusions The novel, resulting 3D full torso model can provide a more complete representation of patient geometry to be incorporated in surgical simulators under development that aim at predicting the effect of scoliosis surgery on the external appearance of the patient’s torso. PMID:23289431
An externally and internally deformable, programmable lung motion phantom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheung, Yam; Sawant, Amit, E-mail: amit.sawant@utsouthwestern.edu
Purpose: Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interior. Such designs do not adequately represent respiration because the thoracic anatomy deforms internally as well as externally. In order to create a closer approximation of respiratory motion, the authors describe the construction and experimental testing of an externally as well as internally deformable, programmable lung phantom. Methods: The outer shell of a commerciallymore » available lung phantom (RS-1500, RSD, Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A custom-made insert was designed using a piece of natural latex foam block. A motion platform was programmed with sinusoidal and ten patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam “diaphragm” that compressed/decompressed the phantom interior. Experimental characterization comprised of determining the reproducibility and the external–internal correlation of external and internal marker trajectories extracted from kV x-ray fluoroscopy. Experiments were conducted to illustrate three example applications of the phantom—(i) validating the geometric accuracy of the VisionRT surface photogrammetry system; (ii) validating an image registration tool, NiftyReg; and (iii) quantifying the geometric error due to irregular motion in four-dimensional computed tomography (4DCT). Results: The phantom correctly reproduced sinusoidal and patient-derived motion, as well as realistic respiratory motion-related effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.25 mm RMS error. The motion trajectories of internal and external radio-opaque markers as measured by fluoroscopy were found to be highly correlated (R > 0.95). Using the phantom, it was demonstrated that the motion trajectories of regions-of-interest on the surface as measured by VisionRT are highly consistent with corresponding fluoroscopically acquired surface marker trajectories, with RMS errors within 0.26 mm. Furthermore, it was shown that the trajectories of external and internal marker trajectories derived from NiftyReg deformation vector fields were within 1 mm root mean square errors comparing to trajectories obtained by segmenting markers from individual fluoro frames. Finally, it was shown that while 4DCT can be used to localize internal markers for sinusoidal motion with reasonable accuracy, the localization error increases significantly (by a factor of ∼2) in the presence of cycle-to-cycle variations that are observed in patient-derived respiratory motion. Conclusions: The authors have developed a realistic externally and internally deformable, programmable lung phantom that will serve as a valuable tool for clinical and investigational motion management studies in thoracic and abdominal radiation therapies.« less
The Conservative Treatment of Pediatric Mandible Fracture With External Nasal Splint.
Sharifi, Reza; Hasheminasab, Mahboube
2016-09-01
The frequency of mandible fractures is relatively less in children compared with adults, but their treatment is significantly more challenging due to the concerns regarding mandible growth and the developing dentition. The authors have introduced a new way of closed reduction by using external nasal splints. In 3 patients aged between 4 and 6-year old with parasymphyseal and body fractures of mandible, fractures were reduced under general anesthesia and thermoplastic nasal splints were directly formed and trimmed to fit the lingual surface of mandible.Splints were fixed to mandible with circummandibular wiring and were retained in place for 3 weeks. All fractures healed uneventfully and the occlusion in all patients was satisfactory. All patients gained good masticatory efficiency. There was no need to use the intermaxillary fixation in any of the patients. Using thermoplastic external nasal splint for fracture stabilization in children is an easy, rapid, nonexpensive, and conservative way to treat mandible fractures in pediatric patients.
Wang, Xu; Zhang, Chao; Yin, Jian-Wen; Wang, Chen; Huang, Jia-Zhang; Ma, Xin; Wang, Cheng-Wei; Wang, Xue
2017-02-01
To investigate the effect of internal fixation on postoperative ankle function in patients with supination-external rotation type IV ankle fractures, including medial malleolus fractures and deltoid ligament injury. Between January 2012 and June 2014, patients with medial structure injuries were enrolled in this study and assigned to the medial malleolus fracture group or the deltoid ligament group. The surgical procedures for the two groups were documented. The follow-up endpoint was the time point when the steel plate or screw was removed from the lateral ankle. The Olerud-Molander ankle scoring system was used to assess ankle function. A total of 84 patients with supination-external rotation type IV ankle fractures had complete medical records and were included in this study. The average age of the patients was 44.16 years (range, 15-75). The patient sample included 39 males and 45 females. Overall, 49 patients (19 males and 30 females) suffered a medial malleolus fracture. The average age of these patients was 40.20 years (range, 15-75). Patients with a posterior malleolar fracture fragment >25% of the articular surface accounted for 81.6% (40 patients) of these patients. Overall, 35 patients (20 males and 15 females) experienced a deltoid ligament injury. The average age of these patients was 44.21 years (range, 17-73). Patients with a posterior malleolar fracture fragment >25% of the articular surface accounted for 11.5% (four patients) of these patients. Open reduction was performed in patients with medial malleolus fractures, and two 4.0-mm cannulated screws were used to fixate the posterior malleolus and the medial malleolus. The suture-anchor technique was used to repair the ligaments in patients with deltoid ligament injuries. The follow-up endpoint was the time point when the steel plate and screws were removed from the lateral ankle in patients. The average follow-up period was 13.4 months (range, 11-17). The Olerud-Molander ankle scoring system was used to assess postoperative ankle function. The average score for the patients in the medial malleolus fracture group was 90.3 points (range, 85-95). The average score for the patients in the deltoid ligament injury group was 87.7 points (range, 80-95). No significant differences were found in the scores between the two groups. Medial malleolus fracture and deltoid ligament injury are two different presentations of supination-external rotation type IV ankle fractures. Anatomic reduction of the articular surface concurrent with restoration of ankle stability can achieve favorable results for these two injuries. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheung, Y; Sawant, A
Purpose: Most clinically-deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating, tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are rigid-exterior+rigid-interior or rigid-exterior+deformable-interior. Neither class adequately represents the human anatomy, which is deformable internally as well as externally. We describe the construction and experimental validation of a more realistic, externally- and internally-deformable, programmable lung phantom. Methods: The outer shell of a commercially-available lung phantom (RS- 1500, RSD Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cagemore » and sternum. A 3-axis platform was programmed with sinusoidal and six patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam ‘diaphragm’ that compressed/decompressed the phantom interior. Experimental characterization comprised of mapping the superior-inferior (SI) and anterior-posterior (AP) trajectories of external and internal radioopaque markers with kV x-ray fluoroscopy and correlating these with optical surface monitoring using the in-room VisionRT system. Results: The phantom correctly reproduced the programmed motion as well as realistic effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.4 mm RMS error for internal as well as external markers. The motion trajectories of internal and external markers as measured by fluoroscopy were found to be highly correlated (R=0.97). Furthermore, motion trajectories of arbitrary points on the deforming phantom surface, as recorded by the VisionRT system also showed a high correlation with respect to the fluoroscopically-measured trajectories of internal markers (R=0.92). Conclusion: We have developed a realistic externally- and internally-deformable lung phantom that will serve as a valuable tool for clinical QA and motion management research. This work was supported through funding from the NIH and VisionRT Ltd. Amit Sawant has research funding from Varian Medical Systems, VisionRT and Elekta.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hasan, Yasmin; Kim, Leonard; Martinez, Alvaro
Purpose: To compare localization of the lumpectomy cavity by using breast surface matching vs. clips for image-guided external beam accelerated partial breast irradiation. Methods and Materials: Twenty-seven patients with breast cancer with two computed tomography (CT) scans each had three CT registrations performed: (1) to bony anatomy, (2) to the center of mass (COM) of surgical clips, and (3) to the breast surface. The cavity COM was defined in both the initial and second CT scans after each type of registration, and distances between COMs ({delta}COM{sub Bone}, {delta}COM{sub Clips}, and {delta}COM{sub Surface}) were determined. Smaller {delta}COMs were interpreted as bettermore » localizations. Correlation coefficients were calculated for {delta}COM vs. several variables. Results: The {delta}COM{sub Bone} (mean, 7 {+-} 2 [SD] mm) increased with breast volume (r = 0.4; p = 0.02) and distance from the chest wall (r = 0.5; p = 0.003). Relative to bony registration, clip registration provided better localization ({delta}COM{sub Clips} < {delta}COM{sub Bone}) in 25 of 27 cases. Breast surface matching improved cavity localization ({delta}COM{sub Surface} < {delta}COM{sub Bone}) in 19 of 27 cases. Mean improvements ({delta}COM{sub Bone} - {delta}COM{sub ClipsorSurface}) were 4 {+-} 3 and 2 {+-} 4 mm, respectively. In terms of percentage of improvement ([{delta}COM{sub Bone} - {delta}COM{sub ClipsorSurface}]/{delta}COM{sub Bone}), only surface matching showed a correlation with breast volume. Clip localization outperformed surface registration for cavities located superior to the breast COM. Conclusions: Use of either breast surface or surgical clips as surrogates for the cavity results in improved localization in most patients compared with bony registration and may allow smaller planning target volume margins for external beam accelerated partial breast irradiation. Compared with surface registration, clip registration may be less sensitive to anatomic characteristics and therefore more broadly applicable.« less
Hwang, Euna; Kim, Young Soo; Chung, Seum
2014-06-01
Before visiting a plastic surgeon, some microtia patients may undergo canaloplasty for hearing improvement. In such cases, scarred tissues and the reconstructed external auditory canal in the postauricular area may cause a significant limitation in using the posterior auricular skin flap for ear reconstruction. In this article, we present a new method for auricular reconstruction in microtia patients with previous canaloplasty. By dividing a postauricular skin flap into an upper scalp extended skin flap and a lower mastoid extended skin flap at the level of a reconstructed external auditory canal, the entire anterior surface of the auricular framework can be covered with the two extended postauricular skin flaps. The reconstructed ear shows good color match and texture, with the entire anterior surface of the reconstructed ear being resurfaced with the skin flaps. Clinical question/level of evidence; therapeutic level IV. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Schmidt, Ehud J; Watkins, Ronald D; Zviman, Menekhem M; Guttman, Michael A; Wang, Wei; Halperin, Henry A
2016-10-01
Subjects undergoing cardiac arrest within a magnetic resonance imaging (MRI) scanner are currently removed from the bore and then from the MRI suite, before the delivery of cardiopulmonary resuscitation and defibrillation, potentially increasing the risk of mortality. This precludes many higher-risk (acute ischemic and acute stroke) patients from undergoing MRI and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the seconds of MRI after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by the addition of novel radiofrequency filters between the generator and commercial disposable surface pads. The radiofrequency filters reduced emission into the MRI scanner and prevented cable/surface pad heating during imaging, while preserving all the defibrillator monitoring and delivery functions. Human volunteers were imaged using high specific absorption rate sequences to validate MRI image quality and lack of heating. Swine were electrically fibrillated (n=4) and thereafter defibrillated both outside and inside the MRI bore. MRI image quality was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface pads did not create artifacts deeper than 6 mm below the skin surface. Radiofrequency heating was within US Food and Drug Administration guidelines. Defibrillation was completely successful inside and outside the MRI bore. A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading the image quality or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures. © 2016 American Heart Association, Inc.
Gating based on internal/external signals with dynamic correlation updates.
Wu, Huanmei; Zhao, Qingya; Berbeco, Ross I; Nishioka, Seiko; Shirato, Hiroki; Jiang, Steve B
2008-12-21
Precise localization of mobile tumor positions in real time is critical to the success of gated radiotherapy. Tumor positions are usually derived from either internal or external surrogates. Fluoroscopic gating based on internal surrogates, such as implanted fiducial markers, is accurate however requiring a large amount of imaging dose. Gating based on external surrogates, such as patient abdominal surface motion, is non-invasive however less accurate due to the uncertainty in the correlation between tumor location and external surrogates. To address these complications, we propose to investigate an approach based on hybrid gating with dynamic internal/external correlation updates. In this approach, the external signal is acquired at high frequency (such as 30 Hz) while the internal signal is sparsely acquired (such as 0.5 Hz or less). The internal signal is used to validate and update the internal/external correlation during treatment. Tumor positions are derived from the external signal based on the newly updated correlation. Two dynamic correlation updating algorithms are introduced. One is based on the motion amplitude and the other is based on the motion phase. Nine patients with synchronized internal/external motion signals are simulated retrospectively to evaluate the effectiveness of hybrid gating. The influences of different clinical conditions on hybrid gating, such as the size of gating windows, the optimal timing for internal signal acquisition and the acquisition frequency are investigated. The results demonstrate that dynamically updating the internal/external correlation in or around the gating window will reduce false positive with relatively diminished treatment efficiency. This improvement will benefit patients with mobile tumors, especially greater for early stage lung cancers, for which the tumors are less attached or freely floating in the lung.
[Comparison of external fixation with or without limited internal fixation for open knee fractures].
Li, K N; Lan, H; He, Z Y; Wang, X J; Yuan, J; Zhao, P; Mu, J S
2018-03-01
Objective: To explore the characteristics and methods of different fixation methods and prevention of open knee joint fracture. Methods: The data of 86 cases of open knee joint fracture admitted from January 2002 to December 2015 in Department of Orthopaedics, Affiliated Hospital of Chengdu University were analyzed retrospectively.There were 65 males and 21 females aged of 38.6 years. There were 38 cases treated with trans articular external fixation alone, 48 cases were in the trans articular external fixation plus auxiliary limited internal fixation group. All the patients were treated according to the same three stages except for different fixation methods. Observation of external fixation and fracture fixation, fracture healing, wound healing and treatment, treatment and related factors of infection control and knee function recovery. χ(2) test was used to analyze data. Results: Eleven patients had primary wound healing, accounting for 12.8%. Seventy-five patients had two wounds healed, accounting for 87.2%. Only 38 cases of trans articular external fixator group had 31 cases of articular surface reduction, accounting for 81.6%; Five cases of trans articular external fixator assisted limited internal fixation group had 5 cases of poor reduction, accounting for 10.4%; There was significant difference between the two groups (χ(2)=44.132, P <0.05). Take a single cross joint external fixation group, a total of 23 cases of patients with infection, accounted for 60.5% of external fixation group; trans articular external fixation assisted limited internal fixation group there were 30 cases of patients with infection, accounting for the assistance of external fixator and limited internal fixation group 62.5%; There was significant difference between the two groups(χ(2)=0.035, P >0.05). Five cases of fracture nonunion cases of serious infection, patients voluntarily underwent amputation. The Lysholm Knee Scale: In the external fixation group, 23 cases were less than 50 points, accounting for 60.5%, 15 cases were more than 50 points, accounting for 39.5%, external fixation and limited internal fixation group 20 cases were less than 50 points, accounting for 41.7%, 28 cases were more than 50 points, accounting for 58.3%; There was significant difference between the two groups(χ(2)=1.279, P >0.05). Conclusions: Prevention and control of infection is a central link in the treatment of open fracture of the knee. Trans articular external fixator plus limited internal fixation is an important measure to treat open fracture of the knee-joint.
Haifler, Miki; Ristau, Benjamin T; Higgins, Andrew M; Smaldone, Marc C; Kutikov, Alexander; Zisman, Amnon; Uzzo, Robert G
2017-09-20
We sought to externally validate a mathematical formula for tumor contact surface area as a predictor of postoperative renal function in patients undergoing partial nephrectomy for renal cell carcinoma. We queried a prospectively maintained kidney cancer database for patients who underwent partial nephrectomy between 2014 and 2016. Contact surface area was calculated using data obtained from preoperative cross-sectional imaging. The correlation between contact surface area and perioperative variables was examined. The correlation between postoperative renal functional outcomes, contact surface area and the R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines and tumor touches main renal artery or vein) nephrometry score was also assessed. A total of 257 patients who underwent partial nephrectomy had sufficient data to enter the study. Median contact surface area was 14.5 cm 2 (IQR 6.2-36) and the median nephrometry score was 9 (IQR 7-10). Spearman correlation analysis showed that contact surface area correlated with estimated blood loss (r s = 0.42, p <0.001), length of stay (r s = 0.18, p = 0.005), and percent and absolute change in the estimated glomerular filtration rate (r s = -0.77 and -0.78, respectively, each p <0.001). On multivariable analysis contact surface area and nephrometry score were independent predictors of the absolute change in the estimated glomerular filtration rate (each p <0.001). ROC curve analysis revealed that contact surface area was a better predictor of a greater than 20% postoperative decline in the estimated glomerular filtration rate compared with the nephrometry score (AUC 0.94 vs 0.80). Contact surface area correlated with the change in postoperative renal function after partial nephrectomy. It can be used in conjunction with the nephrometry score to counsel patients about the risk of renal functional decline after partial nephrectomy. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, H; Zhen, X; Zhou, L
Purpose: To propose and validate a novel real-time surface-mesh-based internal organ-external surface motion and deformation tracking method for lung cancer radiotherapy. Methods: Deformation vector fields (DVFs) which characterizes the internal and external motion are obtained by registering the internal organ and tumor contours and external surface meshes to a reference phase in the 4D CT images using a recent developed local topology preserved non-rigid point matching algorithm (TOP). A composite matrix is constructed by combing the estimated internal and external DVFs. Principle component analysis (PCA) is then applied on the composite matrix to extract principal motion characteristics and finally yieldmore » the respiratory motion model parameters which correlates the internal and external motion and deformation. The accuracy of the respiratory motion model is evaluated using a 4D NURBS-based cardiac-torso (NCAT) synthetic phantom and three lung cancer cases. The center of mass (COM) difference is used to measure the tumor motion tracking accuracy, and the Dice’s coefficient (DC), percent error (PE) and Housdourf’s distance (HD) are used to measure the agreement between the predicted and ground truth tumor shape. Results: The mean COM is 0.84±0.49mm and 0.50±0.47mm for the phantom and patient data respectively. The mean DC, PE and HD are 0.93±0.01, 0.13±0.03 and 1.24±0.34 voxels for the phantom, and 0.91±0.04, 0.17±0.07 and 3.93±2.12 voxels for the three lung cancer patients, respectively. Conclusions: We have proposed and validate a real-time surface-mesh-based organ motion and deformation tracking method with an internal-external motion modeling. The preliminary results conducted on a synthetic 4D NCAT phantom and 4D CT images from three lung cancer cases show that the proposed method is reliable and accurate in tracking both the tumor motion trajectory and deformation, which can serve as a potential tool for real-time organ motion and deformation monitoring in lung cancer radiotherapy. This work is supported in part by grant from VARIAN MEDICAL SYSTEMS INC, the National Natural Science Foundation of China (no 81428019 and no 81301940), the Guangdong Natural Science Foundation (2015A030313302)and the 2015 Pearl River S&T Nova Program of Guangzhou (201506010096).« less
NASA Astrophysics Data System (ADS)
Lee, Richard; Chan, Elisa K.; Kosztyla, Robert; Liu, Mitchell; Moiseenko, Vitali
2012-12-01
The relationship between rectal dose distribution and the incidence of late rectal complications following external-beam radiotherapy has been previously studied using dose-volume histograms or dose-surface histograms. However, they do not account for the spatial dose distribution. This study proposes a metric based on both surface dose and distance that can predict the incidence of rectal bleeding in prostate cancer patients treated with radical radiotherapy. One hundred and forty-four patients treated with radical radiotherapy for prostate cancer were prospectively followed to record the incidence of grade ≥2 rectal bleeding. Radiotherapy plans were used to evaluate a dose-distance metric that accounts for the dose and its spatial distribution on the rectal surface, characterized by a logistic weighting function with slope a and inflection point d0. This was compared to the effective dose obtained from dose-surface histograms, characterized by the parameter n which describes sensitivity to hot spots. The log-rank test was used to determine statistically significant (p < 0.05) cut-off values for the dose-distance metric and effective dose that predict for the occurrence of rectal bleeding. For the dose-distance metric, only d0 = 25 and 30 mm combined with a > 5 led to statistical significant cut-offs. For the effective dose metric, only values of n in the range 0.07-0.35 led to statistically significant cut-offs. The proposed dose-distance metric is a predictor of rectal bleeding in prostate cancer patients treated with radiotherapy. Both the dose-distance metric and the effective dose metric indicate that the incidence of grade ≥2 rectal bleeding is sensitive to localized damage to the rectal surface.
Femoral sizing in total knee arthroplasty is rotation dependant.
Koninckx, Angelique; Deltour, Arnaud; Thienpont, Emmanuel
2014-12-01
The mismatch between the medio-lateral (ML) and the antero-posterior (AP) size of femoral components in total knee arthroplasty (TKA) has been linked to gender, ethnicity, morphotype and height differences in patients. The hypothesis of this study was that the AP size measurement of a femoral component increases with more external rotation in posterior referencing TKA. During a 2-year period, 201 patients were included in this prospective study. The AP distance of the distal femur was measured with an AP sizer of the Vanguard (Biomet, Warsaw, US) knee system. This AP sizer allows to dial in external rotation by 1° increments and to determine the femoral size with an anterior boom. AP size was noted at 0°, 3° and 5° of external rotation and then compared for ML matching. Antero-posterior and corresponding ML sizes match perfectly for the Vanguard at 0° of external rotation and a central boom position on the anterior femoral surface. Then, the anterior boom was positioned on the antero-lateral cortex and the AP size increased a mean (SD) 1 (0.5) mm. With 3° of external rotation, the AP size increased a mean (SD) 2.3 (0.4) mm and for 5° a mean (SD) 3.8 (0.3) mm (P < 0.05). This increase in AP size resulted in ML overhang of 2.2 (1.2) mm for 3° and 4.8 (2.6) mm for 5° (P < 0.05). Antero-posterior size measurement of the distal femur is determined by the anatomy of the anterior surface with a higher antero-lateral cortex and the amount of external rotation that is dialled in during surgery. Since these parameters vary case per case, the availability of narrow components offers more surgical options to the surgeon and its importance extends beyond the gender aspect allowing different amounts of external rotation to be used without ML overhang. II.
NASA Astrophysics Data System (ADS)
Čoček, A.; Jandová, A.; Hahn, A.; Mártonová, J.; Ambruš, M.; Dohnalová, A.; Nedbalová, M.; Pokorný, J.
2011-12-01
Our research thus far has concerned the impact of external magnetic fields (50 Hz) and low (0.01-10 mT) induction on adherence capabilities of T lymphocytes obtained from the blood of patients with head and neck tumors. We know that the in vitro adherence capability of T lymphocytes towards surfaces in cancer patients is less than that of control. Previously, we have found that exposure to magnetic fields (50 Hz / 0.01-10 mT) increases the capability of T lymphocytes, in larynx/pharynx cancer patients, to adhere in vitro to surfaces, achieving almost physiological values, in not only pre-treatment patients but also those receiving treatment in the course of follow-up. The capability of T lymphocytes in controls (voluntary blood donors) to adhere to surfaces was also increased (50 Hz / 0.01-0.5 mT). The present study concentrates on the significance of the level of magnetic field induction in order to determine whether low induction values can restore T lymphocytes adherence capabilities. Testing a set of 20 patients showed a statistically significant difference (p < 0.05) in the in vitro adherence capacity of T lymphocytes between both 0.01 and 0.05, and 0.1 mT induction levels. In the control group (patients diagnosed with chronic sensorineural hearing loss) there was even a statistically significant difference between induction values of 0.05 and 0.01 mT. Therefore, we concluded that lower induction values resulted in a more biologically significant response.
Collision prediction software for radiotherapy treatments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Padilla, Laura; Pearson, Erik A.; Pelizzari, Charles A., E-mail: c-pelizzari@uchicago.edu
2015-11-15
Purpose: This work presents a method of collision predictions for external beam radiotherapy using surface imaging. The present methodology focuses on collision prediction during treatment simulation to evaluate the clearance of a patient’s treatment position and allow for its modification if necessary. Methods: A Kinect camera (Microsoft, Redmond, WA) is used to scan the patient and immobilization devices in the treatment position at the simulator. The surface is reconstructed using the SKANECT software (Occipital, Inc., San Francisco, CA). The treatment isocenter is marked using simulated orthogonal lasers projected on the surface scan. The point cloud of this surface is thenmore » shifted to isocenter and converted from Cartesian to cylindrical coordinates. A slab models the treatment couch. A cylinder with a radius equal to the normal distance from isocenter to the collimator plate, and a height defined by the collimator diameter is used to estimate collisions. Points within the cylinder clear through a full gantry rotation with the treatment couch at 0° , while points outside of it collide. The angles of collision are reported. This methodology was experimentally verified using a mannequin positioned in an alpha cradle with both arms up. A planning CT scan of the mannequin was performed, two isocenters were marked in PINNACLE, and this information was exported to AlignRT (VisionRT, London, UK)—a surface imaging system for patient positioning. This was used to ensure accurate positioning of the mannequin in the treatment room, when available. Collision calculations were performed for the two treatment isocenters and the results compared to the collisions detected the room. The accuracy of the Kinect-Skanect surface was evaluated by comparing it to the external surface of the planning CT scan. Results: Experimental verification results showed that the predicted angles of collision matched those recorded in the room within 0.5°, in most cases (largest deviation −1.2°). The accuracy study for the Kinect-Skanect surface showed an average discrepancy between the CT external contour and the surface scan of 2.2 mm. Conclusions: This methodology provides fast and reliable collision predictions using surface imaging. The use of the Kinect-Skanect system allows for a comprehensive modeling of the patient topography including all the relevant anatomy and immobilization devices that may lead to collisions. The use of this tool at the treatment simulation stage may allow therapists to evaluate the clearance of a patient’s treatment position and optimize it before the planning CT scan is performed. This can allow for safer treatments for the patients due to better collision predictions and improved clinical workflow by minimizing replanning and resimulations due to unforeseen clearance issues.« less
NASA Astrophysics Data System (ADS)
Bergeron, Charles; Labelle, Hubert; Ronsky, Janet; Zernicke, Ronald
2005-04-01
Spinal curvature progression in scoliosis patients is monitored from X-rays, and this serial exposure to harmful radiation increases the incidence of developing cancer. With the aim of reducing the invasiveness of follow-up, this study seeks to relate the three-dimensional external surface to the internal geometry, having assumed that that the physiological links between these are sufficiently regular across patients. A database was used of 194 quasi-simultaneous acquisitions of two X-rays and a 3D laser scan of the entire trunk. Data was processed to sets of datapoints representing the trunk surface and spinal curve. Functional data analyses were performed using generalized Fourier series using a Haar basis and functional minimum noise fractions. The resulting coefficients became inputs and outputs, respectively, to an array of support vector regression (SVR) machines. SVR parameters were set based on theoretical results, and cross-validation increased confidence in the system's performance. Predicted lateral and frontal views of the spinal curve from the back surface demonstrated average L2-errors of 6.13 and 4.38 millimetres, respectively, across the test set; these compared favourably with measurement error in data. This constitutes a first robust prediction of the 3D spinal curve from external data using learning techniques.
Li, Yan; He, Linlin; Zhang, Xiaofang; Zhang, Na; Tian, Dongliang
2017-12-01
External-field-responsive liquid transport has received extensive research interest owing to its important applications in microfluidic devices, biological medical, liquid printing, separation, and so forth. To realize different levels of liquid transport on surfaces, the balance of the dynamic competing processes of gradient wetting and dewetting should be controlled to achieve good directionality, confined range, and selectivity of liquid wetting. Here, the recent progress in external-field-induced gradient wetting is summarized for controllable liquid transport from movement on the surface to penetration into the surface, particularly for liquid motion on, patterned wetting into, and permeation through films on superwetting surfaces with external field cooperation (e.g., light, electric fields, magnetic fields, temperature, pH, gas, solvent, and their combinations). The selected topics of external-field-induced liquid transport on the different levels of surfaces include directional liquid motion on the surface based on the wettability gradient under an external field, partial entry of a liquid into the surface to achieve patterned surface wettability for printing, and liquid-selective permeation of the film for separation. The future prospects of external-field-responsive liquid transport are also discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Self-cleaning skin-like prosthetic polymer surfaces
Simpson, John T [Clinton, TN; Ivanov, Ilia N [Knoxville, TN; Shibata, Jason [Manhattan Beach, CA
2012-03-27
An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the inner surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.
Method of making self-cleaning skin-like prosthetic polymer surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, John T.; Ivanov, Ilia N.; Shibata, Jason
An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the innermore » surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.« less
Internal Motion Estimation by Internal-external Motion Modeling for Lung Cancer Radiotherapy.
Chen, Haibin; Zhong, Zichun; Yang, Yiwei; Chen, Jiawei; Zhou, Linghong; Zhen, Xin; Gu, Xuejun
2018-02-27
The aim of this study is to develop an internal-external correlation model for internal motion estimation for lung cancer radiotherapy. Deformation vector fields that characterize the internal-external motion are obtained by respectively registering the internal organ meshes and external surface meshes from the 4DCT images via a recently developed local topology preserved non-rigid point matching algorithm. A composite matrix is constructed by combing the estimated internal phasic DVFs with external phasic and directional DVFs. Principle component analysis is then applied to the composite matrix to extract principal motion characteristics, and generate model parameters to correlate the internal-external motion. The proposed model is evaluated on a 4D NURBS-based cardiac-torso (NCAT) synthetic phantom and 4DCT images from five lung cancer patients. For tumor tracking, the center of mass errors of the tracked tumor are 0.8(±0.5)mm/0.8(±0.4)mm for synthetic data, and 1.3(±1.0)mm/1.2(±1.2)mm for patient data in the intra-fraction/inter-fraction tracking, respectively. For lung tracking, the percent errors of the tracked contours are 0.06(±0.02)/0.07(±0.03) for synthetic data, and 0.06(±0.02)/0.06(±0.02) for patient data in the intra-fraction/inter-fraction tracking, respectively. The extensive validations have demonstrated the effectiveness and reliability of the proposed model in motion tracking for both the tumor and the lung in lung cancer radiotherapy.
NASA Astrophysics Data System (ADS)
Nadège Ilembe Badouna, Audrey; Veres, Cristina; Haddy, Nadia; Bidault, François; Lefkopoulos, Dimitri; Chavaudra, Jean; Bridier, André; de Vathaire, Florent; Diallo, Ibrahima
2012-01-01
The aim of this paper was to determine anthropometric parameters leading to the least uncertain estimate of heart size when connecting a computational phantom to an external beam radiation therapy (EBRT) patient. From computed tomography images, we segmented the heart and calculated its total volume (THV) in a population of 270 EBRT patients of both sexes, aged 0.7-83 years. Our data were fitted using logistic growth functions. The patient age, height, weight, body mass index and body surface area (BSA) were used as explanatory variables. For both genders, good fits were obtained with both weight (R2 = 0.89 for males and 0.83 for females) and BSA (R2 = 0.90 for males and 0.84 for females). These results demonstrate that, among anthropometric parameters, weight plays an important role in predicting THV. These findings should be taken into account when assigning a computational phantom to a patient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conroy, Leigh; Guebert, Alexandra; Smith, Wendy
Purpose: We investigate DIBH breast radiotherapy using the Real-time Position Management (RPM) system with the marker-block placed on the target breast or chest wall. Methods: We measured surface dose for three different RPM marker-blocks using EBT3 Gafchromic film at 0° and 30° incidence. A registration study was performed to determine the breast surface position that best correlates with overall internal chest wall position. Surface and chest wall contours from MV images of the medial tangent field were extracted for 15 patients. Surface contours were divided into three potential marker-block positions on the breast: Superior, Middle, and Inferior. Translational registration wasmore » used to align the partial contours to the first-fraction contour. Each resultant transformation matrix was applied to the chest wall contour, and the minimum distance between the reference chest wall contour and the transformed chest wall contour was evaluated for each pixel. Results: The measured surface dose for the 2-dot, 6-dot, and 4-dot marker-blocks at 0° incidence were 74%, 71%, and 77% of dose to dmax respectively. At 30° beam incidence this increased to 76%, 72%, and 81%. The best external surface position was patient and fraction dependent, with no consistent best choice. Conclusions: The increase in surface dose directly under the RPM block is approximately equivalent to 3 mm of bolus. No marker-block position on the breast surface was found to be more representative of overall chest wall motion; therefore block positional stability and reproducibility can be used to determine optimal placement on the breast or chest wall.« less
Sun, Zhen-Jun; Ye, Bo; Sun, Yi; Zhang, Hong-Hai; Liu, Sheng
2014-07-01
This article describes a novel magnetically maneuverable capsule endoscope system with direction reference for image navigation. This direction reference was employed by utilizing a specific magnet configuration between a pair of external permanent magnets and a magnetic shell coated on the external capsule endoscope surface. A pair of customized Cartesian robots, each with only 4 degrees of freedom, was built to hold the external permanent magnets as their end-effectors. These robots, together with their external permanent magnets, were placed on two opposite sides of a "patient bed." Because of the optimized configuration based on magnetic analysis between the external permanent magnets and the magnetic shell, a simplified control strategy was proposed, and only two parameters, yaw step angle and moving step, were necessary for the employed robotic system. Step-by-step experiments demonstrated that the proposed system is capable of magnetically maneuvering the capsule endoscope while providing direction reference for image navigation. © IMechE 2014.
[Treatment of bacterial infection in the interphalangeal joints of the hand].
Vorderwinkler, K-P; Mühldorfer, M; Pillukat, T; van Schoonhoven, J
2011-07-01
Radical debridement of joint infection, prevention of further infection-related tissue destruction. Septic arthritis of interphalangeal joints in the thumb and fingers. Extensive soft tissue defects. Severe impairment of blood circulation, finger gangrene. Noncompliance for immobilization or for treatment with external fixator. Arthrotomy and irrigation with isotonic solution. Radical tissue debridement. Joint preservation possible only in the absence of infection-related macroscopic cartilage damage. Otherwise, resection of the articular surfaces and secondary arthrodesis. Insertion of antibiotic-coated devices. Temporary immobilization with external fixator. Inpatient postoperative treatment with 5-day intravenous administration of a second-generation cephalosporine (e.g., Cefuroxim®) followed by 7-10 days oral application. Adaptation of antibiotics according to antibiogram results. In joint-preserving procedures, radiographs and fixator removal after 4 weeks, active joint mobilization. If joint surfaces were resected, removal of fixator after 6 weeks; arthrodesis under 3-day intravenous broad-band antibiotic prophylaxis. Splint immobilization until consolidation (6-8 weeks). In 10 of 40 patients, the infected joint could be preserved. All infections healed. After an average duration of therapy of 6 (3-11) weeks, 4 individuals were free of complaints, and 6 patients had minor symptoms. Overall range of motion in the affected finger was reduced by 25-50° in 5 patients. All patients could return to work after 6.6 (4-11) weeks. A total of 30 patients were treated with joint resection and external fixator. After 5.6 (4-8) weeks, arthrodesis was performed, leading to consolidation in 29 patients. One patient underwent amputation after 4 months due to delayed gangrene. Treatment duration was 15.7 (7-25) weeks. Eight patients reported no complaints, 14 suffered mild symptoms, 5 had moderate, and 3 had severe symptoms in daily life. In 15 cases, range of motion was diminished by 10-80° in the remaining joints of the affected finger. Patients could return to work after 16.2 (6-28) weeks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, John T.; Ivanov, Ilia N.; Shibata, Jason
An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the innermore » surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.« less
Efficacy test of a toothpaste in reducing extrinsic dental stain
NASA Astrophysics Data System (ADS)
Agustanti, A.; Ramadhani, S. A.; Adiatman, M.; Rahardjo, A.; Callea, M.; Yavuz, I.; Maharani, D. A.
2017-08-01
This clinical trial compared the external dental stain reduction achieved by tested toothpaste versus placebo in adult patients. In this double-blind, parallel, randomised clinical trial, 45 female volunteers with a mean age of 20 years old were included. All study subjects front teeth were topically applicated with Silver Diamine Fluoride (SDF) to create external dental stains. Subjects were randomized into test (n=22) and control (n=23) groups. Toothpastes were used for two days to analyse the effects of removing external stains on the labial surfaces of all anterior teeth. VITA Easyshade Advance 4.0 was used to measure dental extrinsic stains changes. The analysis showed statistically significant efficacy of the tested toothpaste in reducing external dental stain caused by SDF, comparing to the placebo toothpaste, after one and two days of usage. The tested toothpaste was effective in reducing dental stain.
Change in trunk muscle activities with prone bridge exercise in patients with chronic low back pain.
Kong, Yong-Soo; Park, Seol; Kweon, Mi-Gyong; Park, Ji-Won
2016-01-01
[Purpose] The aim of this study was to determine the effect of three different bridge exercises on internal oblique, external oblique, transverse abdominis, and erector spinae activities. [Subjects and Methods] Forty-five subjects with chronic low back pain participated in this study. The training outcome was evaluated with three different testing methods: supine bridge exercise, supine bridge on Swiss ball exercise, and prone bridge exercise. The activities of the transverse abdominis, internal oblique, external oblique, and erector spinae were measured using surface electromyography. [Results] There were significant differences in the internal oblique, external oblique, and erector spinae according to the three kinds of bridging exercises. The internal oblique, external oblique and transverse abdominis activities were highest in the prone bridge exercise, followed by those in the supine bridge on Swiss ball exercise, and supine bridge exercises. The activity of erector spine was highest in the supine bridge on Swiss ball exercise followed by the supine bridge exercise and prone bridge exercise. [Conclusion] These results suggest that prone bridge exercise is more effective than conventional supine bridge exercise and supine bridge on Swiss ball in increasing trunk muscle activity of chronic low back pain patients.
30 CFR 18.23 - Limitation of external surface temperatures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Limitation of external surface temperatures. 18.23 Section 18.23 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... and Design Requirements § 18.23 Limitation of external surface temperatures. The temperature of the...
30 CFR 18.23 - Limitation of external surface temperatures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Limitation of external surface temperatures. 18.23 Section 18.23 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... and Design Requirements § 18.23 Limitation of external surface temperatures. The temperature of the...
30 CFR 18.23 - Limitation of external surface temperatures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Limitation of external surface temperatures. 18.23 Section 18.23 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... and Design Requirements § 18.23 Limitation of external surface temperatures. The temperature of the...
30 CFR 18.23 - Limitation of external surface temperatures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Limitation of external surface temperatures. 18.23 Section 18.23 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... and Design Requirements § 18.23 Limitation of external surface temperatures. The temperature of the...
Mori, T; Ishida, K; Mukumoto, S; Yamada, Y; Imokawa, G; Kabashima, K; Kobayashi, M; Bito, T; Nakamura, M; Ogasawara, K; Tokura, Y
2010-01-01
Background Two types of atopic dermatitis (AD) have been proposed, with different pathophysiological mechanisms underlying this seemingly heterogeneous disorder. The extrinsic type shows high IgE levels presumably as a consequence of skin barrier damage and feasible allergen permeation, whereas the intrinsic type exhibits normal IgE levels and is not mediated by allergen-specific IgE. Objectives To investigate the relationship between pruritus perception threshold and skin barrier function of patients with AD in a comparison between the extrinsic and intrinsic types. Methods Enrolled in this study were 32 patients with extrinsic AD, 17 with intrinsic AD and 24 healthy individuals. The barrier function of the stratum corneum was assessed by skin surface hydration and transepidermal water loss (TEWL), and pruritus perception was evaluated by the electric current perception threshold (CPT) of sensory nerves upon neuroselective transcutaneous electric stimulation. Results Skin surface hydration was significantly lower and TEWL was significantly higher in extrinsic AD than intrinsic AD or normal controls. Although there was no statistically significant difference in CPT among extrinsic AD, intrinsic AD and normal controls, CPT was significantly correlated with skin surface hydration and inversely with TEWL in intrinsic AD and normal controls, but not extrinsic AD. Finally, CPT was correlated with the visual analogue scale of itch in the nonlesional skin of patients with extrinsic but not intrinsic AD. Conclusions Patients with extrinsic AD have an impaired barrier, which increases the pre-existing pruritus but rather decreases sensitivity to external stimuli. In contrast, patients with intrinsic AD retain a normal barrier function and sensory reactivity to external pruritic stimuli.
Feasibility study of patient motion monitoring by using tactile array sensors
NASA Astrophysics Data System (ADS)
Kim, Tae-Ho; Kang, Seong-Hee; Kim, Dong-Su; Cho, Min-Seok; Kim, Kyeong-Hyeon; Suh, Tae-Suk; Kim, Siyong
2015-07-01
An ideal alignment method based on the external anatomical surface of the patient should consider the entire region of interest. However, optical-camera-based systems cannot blindly monitor such areas as the patient's back, for example. Furthermore, collecting enough information to correct the associated deformation error is impossible. The study aim is to propose a new patient alignment method using tactile array sensors that can measure the distributed pressure profiles along the contact surface. The TactArray system includes one sensor, a signal-conditioning device (USB drive/interface electronics, power supply, and cables), and a PC. The tactile array sensor was placed between the patient's back and the treatment couch, and the deformations at different location on the patient's back were evaluated. Three healthy male volunteers were enrolled in this study, and pressure profile distributions (PPDs) were obtained with and without immobilization. After the initial pretreatment setup using the laser alignment system, the PPD of the patient's back was acquired. The results were obtained at four different times and included a reference PPD dataset. The contact area and the center-of-pressure value were also acquired based on the PPD data for a more elaborate quantitative data analysis. To evaluate the clinical feasibility of using the proposed alignment method for reducing the deformation error, we implemented a real-time self-correction procedure. Despite the initial alignment, we confirmed that PPD variations existed in both cases of the volunteer studies (with and without the use of the immobilization tool). Additionally, we confirmed that the contact area and the center of pressure varied in both cases, and those variations were observed in all three volunteers. With the proposed alignment method and the real-time selfcorrection procedure, the deformation error was significantly reduced. The proposed alignment method can be used to account for the limitation of the camera-based system and to improve the accuracy of the external surface-based patient setup.
Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S
2000-11-01
In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.
Cross-infection risks associated with current procedures for using high-speed dental handpieces.
Lewis, D L; Boe, R K
1992-01-01
When a dye solution used to simulate patient material was either injected into high-speed dental handpiece (drill) waterlines or applied to the equipment externally, internal air turbine chambers became contaminated. These chambers served as a reservoir of the material, which was slowly dislodged by air expelled during subsequent handpiece operation and which was diluted by water spray used for cooling the drilling surface. Considering the fact that patient materials could reside in internal parts of the equipment that are not usually disinfected and that the material may be subsequently sprayed into cuts and abrasions in the oral cavity, the common approach to reprocessing handpieces (external wiping in combination with flushing) may pose unacceptably high risks to those individuals treated soon after infected patients. Therefore, unless reliable data on cross-infection frequencies are obtained and prove it unnecessary, heat-treating high-speed handpieces between each patient should be considered an essential component of standard procedures whenever universal precautions are practiced in dentistry. PMID:1537909
Plath, Johannes E; Seiberl, Wolfgang; Beitzel, Knut; Minzlaff, Philipp; Schwirtz, Ansgar; Imhoff, Andreas B; Buchmann, Stefan
2014-08-01
The purpose of this study was to investigate coactivation (CoA) testing as a clinical tool to monitor motor learning after latissimus dorsi tendon transfer. We evaluated 20 patients clinically with the American Shoulder and Elbow Surgeons (ASES) and University of California-Los Angeles (UCLA) outcomes scores, visual analog scale, active external rotation (aER), and isometric strength testing in abduction and external rotation. Measurements of aER were performed while the latissimus dorsi was activated in its new function of external rotation with concomitant activation (coactivation) of its native functions (adduction and extension). Bilateral surface electromyographic (EMG) activity was recorded during aER measurements and the strength testing procedure (EMG activity ratio: with/without CoA). Patients were divided into two groups (excellent/good vs fair/poor) according to the results of the ASES and UCLA scores. The mean follow-up was 57.8 ± 25.2 months. Subdivided by clinical scores, the superior outcome group lost aER with CoA, whereas the inferior outcome group gained aER (UCLA score: -2.2° ± 7.4° vs +4.3° ± 4.1°; P = .031). Patients with inferior outcomes in the ASES score showed higher latissimus dorsi EMG activity ratios (P = .027), suggesting an inadequate motor learning process. Isometric strength testing revealed that the latissimus dorsi transfer had significantly greater activity compared with the contralateral side (external rotation, P = .008; abduction, P = .006) but did not have comparable strength (external rotation, P = .017; abduction, P = .009). Patients with inferior clinical results were more likely to be dependent on CoA to gain external rotation. Therefore, CoA testing may be used as a tool to evaluate the status of postoperative motor learning after latissimus dorsi transfer. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Suppression of multipactor discharge on a dielectric surface by an external magnetic field
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai Libing; Zhu Xiangqin; Wang Yue
2011-07-15
The multipactor discharge on a dielectric surface in an external magnetic field is simulated by using the particle-in-cell method, and the electron number, energy, the velocity of the yield of secondary electrons, and the power deposited on dielectric surface in the process of multipactor discharge are investigated. The effects of the strength of the external magnetic field on multipactor are studied. The results show that when the external magnetic field reaches a certain value, the multipactor is weaker than that in the case of no external magnetic field and becomes much lighter versus the strength of the external magnetic fieldmore » in the half microwave period in which the ExB drift pulls the electrons back to dielectric surface. And in the other half microwave period in which the ExB drift pushes the electrons away from the dielectric surface, the multipactor is cut off. So the power capability can be increased to the fourfold by the suppression of multipactor by applying an external magnetic field.« less
Assessment of hospital daily cleaning practices using ATP bioluminescence in a developing country.
Zambrano, Alejandra A; Jones, Alex; Otero, Paula; Ajenjo, Maria Cristina; Labarca, Jaime A
2014-01-01
Visual assessment of surfaces may not be enough to document the level of cleanliness in the hospital setting. It is necessary to introduce quantitative methods to document the results of this practice. To evaluate the efficacy of hospital terminal cleaning procedures, using an adenosine triphosphate (ATP) bioluminescence method in a teaching hospital. During 2008 we conducted an evaluation using ATP bioluminescence LIGHTNING MVP™ (Arquimed) of external and internal housekeeping service. After conducting an initial evaluation we implemented education of cleaning practices and finally we did a post intervention evaluation. Using chi-square method we compared prior versus after cleaning, quality of cleaning performed by external versus internal personnel, single versus double terminal cleaning procedures and prior versus after intervention. A finding of three RLU or less was considered a clean surface. We performed 198 evaluations in 33 patient units and nine OR. Internal personnel accomplished 25.37% of clean surfaces before and 80% after the education intervention (p=0.01). In contrast, external personnel obtained 68.8% before and 73.33% after intervention (p=0.3). This study suggests that visual assessment is not enough to ensure quality of the process and it is necessary to document the level of cleanliness by quantitative methods. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.
Deye, Nicolas; Cariou, Alain; Girardie, Patrick; Pichon, Nicolas; Megarbane, Bruno; Midez, Philippe; Tonnelier, Jean-Marie; Boulain, Thierry; Outin, Hervé; Delahaye, Arnaud; Cravoisy, Aurélie; Mercat, Alain; Blanc, Pascal; Santré, Charles; Quintard, Hervé; Brivet, François; Charpentier, Julien; Garrigue, Delphine; Francois, Bruno; Quenot, Jean-Pierre; Vincent, François; Gueugniaud, Pierre-Yves; Mira, Jean-Paul; Carli, Pierre; Vicaut, Eric; Baud, Frédéric J
2015-07-21
Targeted temperature management is recommended after out-of-hospital cardiac arrest. Whether advanced internal cooling is superior to basic external cooling remains unknown. The aim of this multicenter, controlled trial was to evaluate the benefit of endovascular versus basic surface cooling. Inclusion criteria were the following: age of 18 to 79 years, out-of-hospital cardiac arrest related to a presumed cardiac cause, time to return of spontaneous circulation <60 minutes, delay between return of spontaneous circulation and inclusion <240 minutes, and unconscious patient after return of spontaneous circulation and before the start of cooling. Exclusion criteria were terminal disease, pregnancy, known coagulopathy, uncontrolled bleeding, temperature on admission <30°C, in-hospital cardiac arrest, immediate need for extracorporeal life support or hemodialysis. Patients were randomized between 2 cooling strategies: endovascular femoral devices (Icy catheter, Coolgard, Zoll, formerly Alsius; n=203) or basic external cooling using fans, a homemade tent, and ice packs (n=197). The primary end point, that is, favorable outcome evaluated by survival without major neurological damage (Cerebral Performance Categories 1-2) at day 28, was not significantly different between groups (odds ratio, 1.41; 95% confidence interval, 0.93-2.16; P=0.107). Improvement in favorable outcome at day 90 in favor of the endovascular group did not reach significance (odds ratio, 1.51; 95% confidence interval, 0.96-2.35; P=0.07). Time to target temperature (33°C) was significantly shorter and target hypothermia was more strictly maintained in the endovascular than in the surface group (P<0.001). Minor side effects directly related to the cooling method were observed more frequently in the endovascular group (P=0.009). Despite better hypothermia induction and maintenance, endovascular cooling was not significantly superior to basic external cooling in terms of favorable outcome. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00392639. © 2015 American Heart Association, Inc.
A 4D global respiratory motion model of the thorax based on CT images: A proof of concept.
Fayad, Hadi; Gilles, Marlene; Pan, Tinsu; Visvikis, Dimitris
2018-05-17
Respiratory motion reduces the sensitivity and specificity of medical images especially in the thoracic and abdominal areas. It may affect applications such as cancer diagnostic imaging and/or radiation therapy (RT). Solutions to this issue include modeling of the respiratory motion in order to optimize both diagnostic and therapeutic protocols. Personalized motion modeling required patient-specific four-dimensional (4D) imaging which in the case of 4D computed tomography (4D CT) acquisition is associated with an increased dose. The goal of this work was to develop a global respiratory motion model capable of relating external patient surface motion to internal structure motion without the need for a patient-specific 4D CT acquisition. The proposed global model is based on principal component analysis and can be adjusted to a given patient anatomy using only one or two static CT images in conjunction with a respiratory synchronized patient external surface motion. It is based on the relation between the internal motion described using deformation fields obtained by registering 4D CT images and patient surface maps obtained either from optical imaging devices or extracted from CT image-based patient skin segmentation. 4D CT images of six patients were used to generate the global motion model which was validated by adapting it on four different patients having skin segmented surfaces and two other patients having time of flight camera acquired surfaces. The reproducibility of the proposed model was also assessed on two patients with two 4D CT series acquired within 2 weeks of each other. Profile comparison shows the efficacy of the global respiratory motion model and an improvement while using two CT images in order to adapt the model. This was confirmed by the correlation coefficient with a mean correlation of 0.9 and 0.95 while using one or two CT images respectively and when comparing acquired to model generated 4D CT images. For the four patients with segmented surfaces, expert validation indicates an error of 2.35 ± 0.26 mm compared to 6.07 ± 0.76 mm when using a simple interpolation between full inspiration (FI) and full expiration (FE) CT only; i.e., without specific modeling of the respiratory motion. For the two patients with acquired surfaces, this error was of 2.48 ± 0.18 mm. In terms of reproducibility, model error changes of 0.12 and 0.17 mm were measured for the two patients concerned. The framework for the derivation of a global respiratory motion model was developed. A single or two static CT images and associated patient surface motion, as a surrogate measure, are only needed to personalize the model. This model accuracy and reproducibility were assessed by comparing acquired vs model generated 4D CT images. Future work will consist of assessing extensively the proposed model for radiotherapy applications. © 2018 American Association of Physicists in Medicine.
Hamiltonian surface charges using external sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Troessaert, Cédric, E-mail: troessaert@cecs.cl
2016-05-15
In this work, we interpret part of the boundary conditions as external sources in order to partially solve the integrability problem present in the computation of surface charges associated to gauge symmetries in the hamiltonian formalism. We start by describing the hamiltonian structure of external symmetries preserving the action up to a transformation of the external sources of the theory. We then extend these results to the computation of surface charges for field theories with non-trivial boundary conditions.
NASA Astrophysics Data System (ADS)
Tahavori, Fatemeh
Respiratory motion induces uncertainty in External Beam Radiotherapy (EBRT), which can result in sub-optimal dose delivery to the target tissue and unwanted dose to normal tissue. The conventional approach to managing patient respiratory motion for EBRT within the area of abdominal-thoracic cancer is through the use of internal radiological imaging methods (e.g. Megavoltage imaging or Cone-Beam Computed Tomography) or via surrogate estimates of tumour position using external markers placed on the patient chest. This latter method uses tracking with video-based techniques, and relies on an assumed correlation or mathematical model, between the external surrogate signal and the internal target position. The marker's trajectory can be used in both respiratory gating techniques and real-time tracking methods. Internal radiological imaging methods bring with them limited temporal resolution, and additional radiation burden, which can be addressed by external marker-based methods that carry no such issues. Moreover, by including multiple external markers and placing them closer to the internal target organs, the effciency of correlation algorithms can be increased. However, the quality of such external monitoring methods is underpinned by the performance of the associated correlation model. Therefore, several new approaches to correlation modelling have been developed as part of this thesis and compared using publicly-available datasets. Highly competitive results have been obtained when compared against state-of-the-art methods. Marker-based methods also have the disadvantages of requiring manual set-up time for marker placement and patient positioning and potential issues with reproducibility of marker placement. This motivates the investigation of non-contact marker-free methods for use in EBRT, which is the main topic of this thesis. The Microsoft Kinect is used as an example of a low-cost consumer grade 3D depth camera for capturing and analysing external respiratory motion. This thesis makes the first presentation of detailed studies of external respiratory motion captured using such low-cost technology and demonstrates its potential in a healthcare environment. Firstly, the fundamental performance of a range of Microsoft Kinect sensors is assessed for use in radiotherapy (and potentially other healthcare applications), in terms of static and dynamic performance using both phantoms and volunteers. Then external respiratory motion is captured using the above technology from a group of 32 healthy volunteers and Principal Component Analysis (PCA) is applied to a region of interest encompassing the complete anterior surface to demonstrate breathing style. This work demonstrates that this surface motion can be compactly described by the first two PCA eigenvectors. The reproducibility of subject-specific EBRT set-up using conventional laser-based alignment and marker-based Deep Inspiration Breath Hold (DIBH) methods are also studied using the Microsoft Kinect sensor. A cohort of five healthy female volunteers is repeatedly set-up for left-sided breast cancer EBRT and multiple DIBH episodes captured over five separate sessions representing multiple fractionated radiotherapy treatment sessions, but without dose delivery. This provided an independent assessment that subjects were set-up and generally achieved variations within currently accepted margins of clinical practice. Moreover, this work demonstrated the potential role of consumer-grade 3D depth camera technology as a possible replacement for marker based set-up and DIBH management procedures. This brings with it the additional benefits of low cost, and potential through-put benefits, as patient set-up could ultimately be fully automated with this technology, and DIBH could be independently monitored without requiring preparatory manual intervention.
NASA Technical Reports Server (NTRS)
Cohn, R. B. (Inventor)
1983-01-01
A mounting device for securing a microphone pick up head flush with respect to the external surfaces of the skin of an aircraft for detecting shock waves passing thereover is described. The mount includes a sleeve mounted internally of the aircraft for capturing and supporting an electronics package having the microphone pick up head attached thereto in a manner such that the head is flush with the external surface of the aircraft skin and a pressure seal is established between the internal and external surfaces of the aircraft skin.
Xu, Chuan; Huang, Xin-En; Wang, Shu-Xiang; Lv, Peng-Hua; Sun, Ling; Wang, Fu-An
2015-01-01
Percutaneous transhepatic biliary drainage (PTBD) is a form of palliative care for patients with malignant obstructive jaundice. We here compared the infection incidence between internal-external and external drainage for patients with malignant obstructive jaundice. Patients with malignant obstructive jaundice without infection before surgery receiving internal-external or external drainage from January 2008 to July 2014 were recruited. According to percutaneous transhepatic cholangiography (PTC), if the guide wire could pass through the occlusion and enter the duodenum, we recommended internal-external drainage, and external drainage biliary drainage was set up if the occlusion was not crossed. All patients with infection after procedure received a cultivation of blood and a bile bacteriological test. Among 110 patients with malignant obstructive jaundice, 22 (52.4%) were diagnosed with infection after the procedure in the internal-external drainage group, whereas 19 (27.9%) patients were so affected in the external drainage group, the difference being significant (p<0.05). In 8 patients (36.3%) in the internal-external group infection was controlled, as compared to 12 (63.1%) in the external group (p<0.05). The mortality rate for patients with infection not controlled in internal-external group in one month was 42.8%, while this rate in external group was 28.6% (p<0.05). External drainage is a good choice, which could significantly reduce the chance of biliary infection caused by bacteria, and decrease the mortality rate at one month and improve the long-term prognosis.
An Ultrasound Surface Wave Technique for Assessing Skin and Lung Diseases.
Zhang, Xiaoming; Zhou, Boran; Kalra, Sanjay; Bartholmai, Brian; Greenleaf, James; Osborn, Thomas
2018-02-01
Systemic sclerosis (SSc) is a multi-organ connective tissue disease characterized by immune dysregulation and organ fibrosis. Severe organ involvement, especially of the skin and lung, is the cause of morbidity and mortality in SSc. Interstitial lung disease (ILD) includes multiple lung disorders in which the lung tissue is fibrotic and stiffened. The purpose of this study was to translate ultrasound surface wave elastography (USWE) for assessing patients with SSc and/or ILD via measuring surface wave speeds of both skin and superficial lung tissue. Forty-one patients with both SSc and ILD and 30 healthy patients were enrolled in this study. An external harmonic vibration was used to generate the wave propagation on the skin or lung. Three excitation frequencies of 100, 150 and 200 Hz were used. An ultrasound probe was used to measure the wave propagation in the tissue non-invasively. Surface wave speeds were measured on the forearm and upper arm of both left and right arm, as well as the upper and lower lungs, through six intercostal spaces of patients and healthy patients. Viscoelasticity of the skin was calculated by the wave speed dispersion with frequency using the Voigt model. The magnitudes of surface wave speed and viscoelasticity of patients' skin were significantly higher than those of healthy patients (p <0.0001) for each location and each frequency. The surface wave speeds of patients' lung were significantly higher than those of healthy patients (p <0.0001) for each location and each frequency. USWE is a non-invasive and non-ionizing technique for measuring both skin and lung surface wave speed and may be useful for quantitative assessment of SSc and/or ILD. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.
Andrini, Olga; Keck, Mathilde; L'Hoste, Sébastien; Briones, Rodolfo; Mansour-Hendili, Lamisse; Grand, Teddy; Sepúlveda, Francisco V; Blanchard, Anne; Lourdel, Stéphane; Vargas-Poussou, Rosa; Teulon, Jacques
2014-09-01
ClC-Kb, a member of the ClC family of Cl(-) channels/transporters, plays a major role in the absorption of NaCl in the distal nephron. CLCNKB mutations cause Bartter syndrome type 3, a hereditary renal salt-wasting tubulopathy. Here, we investigate the functional consequences of a Val to Met substitution at position 170 (V170M, α helix F), which was detected in eight patients displaying a mild phenotype. Conductance and surface expression were reduced by ~40-50 %. The regulation of channel activity by external H(+) and Ca(2+) is a characteristic property of ClC-Kb. Inhibition by external H(+) was dramatically altered, with pKH shifting from 7.6 to 6.0. Stimulation by external Ca(2+) on the other hand was no longer detectable at pH 7.4, but was still present at acidic pH values. Functionally, these regulatory modifications partly counterbalance the reduced surface expression by rendering V170M hyperactive. Pathogenic Met170 seems to interact with another methionine on α helix H (Met227) since diverse mutations at this site partly removed pH sensitivity alterations of V170M ClC-Kb. Exploring other disease-associated mutations, we found that a Pro to Leu substitution at position 124 (α helix D, Simon et al., Nat Genet 1997, 17:171-178) had functional consequences similar to those of V170M. In conclusion, we report here for the first time that ClC-Kb disease-causing mutations located around the selectivity filter can result in both reduced surface expression and hyperactivity in heterologous expression systems. This interplay must be considered when analyzing the mild phenotype of patients with type 3 Bartter syndrome.
Aygün, Nurcihan; Uludağ, Mehmet; İşgör, Adnan
2017-01-01
Objective We evaluated the contribution of intraoperative neuromonitoring to the visual and functional identification of the external branch of the superior laryngeal nerve. Material and Methods The prospectively collected data of patients who underwent thyroid surgery with intraoperative neuromonitoring for external branch of the superior laryngeal nerve exploration were assessed retrospectively. The surface endotracheal tube-based Medtronic NIM3 intraoperative neuromonitoring device was used. The external branch of the superior laryngeal nerve function was evaluated by the cricothyroid muscle twitch. In addition, contribution of external branch of the superior laryngeal nerve to the vocal cord adduction was evaluated using electromyographic records. Results The study included data of 126 (female, 103; male, 23) patients undergoing thyroid surgery, with a mean age of 46.2±12.2 years (range, 18–75 years), and 215 neck sides were assessed. Two hundred and one (93.5%) of 215 external branch of the superior laryngeal nerves were identified, of which 60 (27.9%) were identified visually before being stimulated with a monopolar stimulator probe. Eighty-nine (41.4%) external branch of the superior laryngeal nerves were identified visually after being identified with a probe. Although 52 (24.1%) external branch of the superior laryngeal nerves were identified with a probe, they were not visualized. Intraoperative neuromonitoring provided a significant contribution to visual (p<0.001) and functional (p<0.001) identification of external branch of the superior laryngeal nerves. Additionally, positive electromyographic responses were recorded from 160 external branch of the superior laryngeal nerves (74.4%). Conclusion Intraoperative neuromonitoring provides an important contribution to visual and functional identification of external branch of the superior laryngeal nerves. We believe that it can not be predicted whether the external branch of the superior laryngeal nerve is at risk or not and the nerve is often invisible; thus, intraoperative neuromonitoring may routinely be used in superior pole dissection. Glottic electromyography response obtained via external branch of the superior laryngeal nerve stimulation provides quantifiable information in addition to the simple visualization of the cricothyroid muscle twitch. PMID:28944328
Nakamura, T; Hayashi, Y; Watabe, H; Matsumoto, M; Horikawa, T; Fujiwara, T; Ito, M; Yanai, K
1998-02-01
We have developed a method for obtaining the cumulated activities in organs from radionuclides, which are injected into the patient in nuclear medicine procedures, by external exposure measurement with thermoluminescent dosimeters (TLDs) which are attached to the patient's body surface close to source organs to obtain information on body-surface doses. As the surface dose is connected to the cumulated activities in source organs through radiation transmission in the human body which can be estimated with the aid of a mathematical phantom, the organ cumulated activities can be obtained by the inverse transform method. The accuracy of this method was investigated by using a water phantom in which several gamma-ray volume sources of known activity were placed to simulate source organs. We then estimated by external measurements the organ cumulated activities and absorbed doses in subjects to whom the radiopharmaceuticals 11C-labelled Doxepin, 11C-labelled YM09151-2 and 11C-labelled Benzotropin were administered in clinical nuclear medicine procedures. The cumulated activities in the brain obtained with TLDs for Doxepin and YM09151-2 are 63.6 +/- 6.2 and 32.1 +/- 12.0 kBq h MBq-1 respectively, which are compared with the respective values of 33.3 +/- 9.9 and 23.9 +/- 6.2 kBq h MBq-1 with direct PET (positron emission tomography) measurements. The agreement between the two methods is within a factor of two. The effective doses of Doxepin, YM09151-2 and Benzotropin are determined as 6.92 x 10(-3), 7.08 x 10(-3) and 7.65 x 10(-3) mSv MBq-1 respectively with the TLD method. This method has great advantages, in that cumulated activities in several organs can be obtained easily with a single procedure, and the measurements of body surface doses are performed simultaneously with the nuclear medicine procedure, as TLDs are too small to interfere with other medical measurements.
Perdzyński, Wojciech; Adamek, Marek
2015-01-01
The aim of the study was to report long-term results of treatment of patients with congenital penile curvature (CPC) with a new corporoplasty based on stratified structure of tunica albuginea, in which corporal bodies are not opened. From October 2006 to September 2013, the authors operated on 111 adult men with CPC. Ventral curvature was detected in 65 patients, lateral in 34, and dorsal in 12. Skin was incised longitudinally on convex surface of curvature. In ventral curvature, dorsal neuro-vascular bundles (NVBs) were separated from tunica albuginea and elliptical fragments of external (longitudinal) layer of tunica were excised. The tunica was sutured with absorbable sutures, which invaginated the internal (transversal) layer of tunica. In dorsal curvature, excisions were performed on both sides of the urethra, in lateral curvature - on the convex penile surface. Follow-up period was from 12 to 84 months. The penis was completely straight in 109 out of 111 patients. In 2 patients (1.8%) recurrent curvature of up to 20 degrees was detected. Redo surgery was done in one individual (0.9%) at patient's request. Glandular sensation loss or erectile dysfunction was not detected in any patient during the period of observation. A new operation for correction of CPC, which consists of excision of an elliptical fragment of the external layer of the tunica albuginea and plication of the internal layer gives good short and long-term results. Surgery done without penetrating the corpora cavernosa is minimally invasive, which diminishes the potential risk of complications, especially intra- and postoperative bleeding.
NASA Astrophysics Data System (ADS)
Hirose, Junichi; Oshima, Tomomitsu; Fujimori, Yoshiharu; Uchida, Yasumi
1993-05-01
Recent advances in fiberoptic technology enabled us to observe percutaneously the cardiac chambers and valves. We examined left ventricular luminal and valvular changes by percutaneous fiberoptic angioscopy in patients with rheumatic valvular disease. Six patients with echocardiographic rheumatic changes in the mitral valves, underwent angioscopy during routine cardiac catheterization. The fiberscope 4.2 F in diameter, and the guiding catheter 9 F in external diameter with an inflatable balloon around the distal most tip were used for angioscopy. The left ventricular endocardial surface was diffusely white in color or white and brown in mosaic fashion. Echocardiography and angiography had low sensitivity for detecting the changes of the left ventricular luminal surface. Whitish changes which were observed by angioscopy were not related to the indices derived from echocardiography and angiography. The results indicate the possibility of percutaneous angioscopy in detecting left ventricular luminal changes in patients with rheumatic valvular disease.
Singalavanija, Tassapol; Ausayakhun, Somsanguan; Tangmonkongvoragul, Chulaluck
2018-01-01
Human immunodeficiency virus (HIV) causes impairment to the human immune system which leads to immunocompromised conditions, including ocular complications. Several important HIV-associated disorders may involve the anterior segment, ocular surface, and adnexae organ such as dry eye, blepharitis which reduce quality of life of patients. In present, potent antiretroviral therapies HAART (highly active antiretroviral therapy) has improved the length and quality of life which may lead to an increased prevalence of anterior segment ocular disorders. Hence, this study has been undertaken to identify the prevalence and associated factors of anterior segment and external ocular disorder in HIV infected patients in the era of HAART. A prospective descriptive cross sectional study was carried out in HIV positive patients conducted at the Department of Ophthalmology, Chiang Mai University Hospital, from February 2014 to October 2015. Detail history and ocular examination was carried out to examine for anterior segment and external ocular disorders. A total number of 363 patients were included for this prospective cross-sectional study. From the total of 363 patients, 123 patients had an anterior segment and external ocular disorder which account as the prevalence of 33.9%. The most common anterior segment manifestations was dry eye seen in 36 patients (9.9%), followed by posterior blepharitis (Meibomian gland dysfunction) seen in 23 patients (6.3%) and anterior blepharitis seen in 12 patients (3.3%). Other ocular complications included microvasculopathy, immune recovery uveitis, conjunctivitis, papilloma, anterior uveitis, corneal ulcer, nevus, trichiasis, molluscum contangiosum, Kaposi sarcoma, interstitial keratitis, conjunctival lymphangiectasia, dacryocystitis, vernal keratoconjunctivitis and eyelid penicilosis. In this study, the prevalance of anterior segment disorders was higher than in the preHAART era. Dry eye, blepharitis and uveitis were the top three most common anterior segment disorders in the HAART era. The statistical analysis showed no association between age, sex, CD4 count, duration of infection or receiving HAART and anterior segment disorders. Anterior segment abnormalities reduce the quality of life of patients, so ophthalmologists have to be aware and complete ocular examination should be performed in all HIV infected patients.
Ausayakhun, Somsanguan
2018-01-01
Human immunodeficiency virus (HIV) causes impairment to the human immune system which leads to immunocompromised conditions, including ocular complications. Several important HIV-associated disorders may involve the anterior segment, ocular surface, and adnexae organ such as dry eye, blepharitis which reduce quality of life of patients. In present, potent antiretroviral therapies HAART (highly active antiretroviral therapy) has improved the length and quality of life which may lead to an increased prevalence of anterior segment ocular disorders. Hence, this study has been undertaken to identify the prevalence and associated factors of anterior segment and external ocular disorder in HIV infected patients in the era of HAART. A prospective descriptive cross sectional study was carried out in HIV positive patients conducted at the Department of Ophthalmology, Chiang Mai University Hospital, from February 2014 to October 2015. Detail history and ocular examination was carried out to examine for anterior segment and external ocular disorders. A total number of 363 patients were included for this prospective cross-sectional study. From the total of 363 patients, 123 patients had an anterior segment and external ocular disorder which account as the prevalence of 33.9%. The most common anterior segment manifestations was dry eye seen in 36 patients (9.9%), followed by posterior blepharitis (Meibomian gland dysfunction) seen in 23 patients (6.3%) and anterior blepharitis seen in 12 patients (3.3%). Other ocular complications included microvasculopathy, immune recovery uveitis, conjunctivitis, papilloma, anterior uveitis, corneal ulcer, nevus, trichiasis, molluscum contangiosum, Kaposi sarcoma, interstitial keratitis, conjunctival lymphangiectasia, dacryocystitis, vernal keratoconjunctivitis and eyelid penicilosis. In this study, the prevalance of anterior segment disorders was higher than in the preHAART era. Dry eye, blepharitis and uveitis were the top three most common anterior segment disorders in the HAART era. The statistical analysis showed no association between age, sex, CD4 count, duration of infection or receiving HAART and anterior segment disorders. Anterior segment abnormalities reduce the quality of life of patients, so ophthalmologists have to be aware and complete ocular examination should be performed in all HIV infected patients. PMID:29466424
NASA Astrophysics Data System (ADS)
Yoon, Seokjin; Kasai, Akihide
2017-11-01
The dominant external forcing factors influencing estuarine circulation differ among coastal environments. A three-dimensional regional circulation model was developed to estimate external influence indices and relative contributions of external forcing factors such as external oceanic forcing, surface heat flux, wind stress, and river discharge to circulation and hydrographic properties in Tango Bay, Japan. Model results show that in Tango Bay, where the Tsushima Warm Current passes offshore of the bay, under conditions of strong seasonal winds and river discharge, the water temperature and salinity are strongly influenced by surface heat flux and river discharge in the surface layer, respectively, while in the middle and bottom layers both are mainly controlled by open boundary conditions. The estuarine circulation is comparably influenced by all external forcing factors, the strong current, surface heat flux, wind stress, and river discharge. However, the influence degree of each forcing factor varies with temporal variations in external forcing factors as: the influence of open boundary conditions is higher in spring and early summer when the stronger current passes offshore of the bay, that of surface heat flux reflects the absolute value of surface heat flux, that of wind stress is higher in late fall and winter due to strong seasonal winds, and that of river discharge is higher in early spring due to snow-melting and summer and early fall due to flood events.
Zhong, Qun; Wu, Xue-yin; Shen, Qing-yi; Shen, Qing-ping
2012-04-01
To compare the difference in oblique external ridge, oblique internal ridge and alveolar process crest of lower complete denture base made through functional impression and anatomic impression techniques. Fifteen patients were chosen to treat with two kinds of complete dentures through functional impression and anatomic impression technique respectively. 3D laser scanner was used to scan the three-dimensional model of the denture base and the differences of the surface structural between two techniques in alveolar process crest, external and internal oblique ridges were analyzed, using paired t test with SPSS 12.0 software package. Between the two techniques, there were significant differences in the areas of internal and external oblique ridge(P<0.01); there was no significant difference in the main support areas(P>0.05). The results explain why there is less tenderness when functional impression technique is applied. The differences measured also indicate that sufficient buffering should be made in external and internal oblique ridge areas in clinic.
Qin, S H; Guo, B F; Zheng, X J; Jiao, S F; Xia, H T; Peng, A M; Pan, Q; Zang, J C; Wang, Z J
2017-09-01
Objective: To discuss the clinical application and effects of domestic external fixator in the treatment of patients with malformations of limbs. Methods: A total of 7 289 patients with malformation of limbs who had been operated in Qin Sihe orthopedic surgery team from January 1989 to June 2016 were retrospective analyzed. The patients were treated with domestic external fixator, including 4 033 males and 3 256 females, aging from 2 to 82 years with a mean age of 23.4 years. There were 2 732 patients using Ilizarov external fixator, 4 713 patients using hybrid external fixator, 57 patients using monobrachial external fixator, 232 patients using Ilizarov external fixator and hybrid external fixator. The Ilizarov, hybrid and monobrachial external fixator were used in 67, 65 and 0 patients on the upper limbs and in 2 665, 4 616 and 57 patients on the lower limbs. There were 3 028 patients operated on the left limbs, 3 260 patients operated on the right limbs and 1 001 patients operated on the bilateral limbs. The top three types of diseases were sequelae of poliomyelitis, cerebral palsy and post-traumatic stress disorder peromely. Deformity types inclued talipes equinovarus, knee flexion deformity, cavus foot and so on. Results: All the patients were followed up for a period of 2.5 months to 22.4 years, with an average follow-up time of 5.4 years. All of the external fixators were used for single once, and there was no substitute for external fixator quality problem. All the patients were completed surgery goal until removing external fixation except 1 patient gave up treatment and 1 removed the fixator because of metal allergy. The common complications included wire or pin infection and joint movement limitation and so on. Conclusions: The domestic external fixator developed and produced based on the characteristics of Chinese limb deformity disability. The domestic external fixator can be used to treat kinds of limb deformities with the advantages of practical, economical, adjustable, universal and portable. The domestic external fixator could meet the clinical demand for fixation of the osteotomy end of the limbs, the correction of the deformity, the repair of the defects and the limb lengthening.
Effects of five hindfoot arthrodeses on foot and ankle motion: Measurements in cadaver specimens
Zhang, Kun; Chen, Yanxi; Qiang, Minfei; Hao, Yini
2016-01-01
Single, double, and triple hindfoot arthrodeses are used to correct hindfoot deformities and relieve chronic pain. However, joint fusion may lead to dysfunction in adjacent articular surfaces. We compared range of motion in adjacent joints before and after arthrodesis to determine the effects of each procedure on joint motion. The theory of moment of couple, bending moment and balanced loading was applied to each of 16 fresh cadaver feet to induce dorsiflexion, plantarflexion, internal rotation, external rotation, inversion, and eversion. Range of motion was measured with a 3-axis coordinate measuring machine in a control foot and in feet after subtalar, talonavicular, calcaneocuboid, double, or triple arthrodesis. All arthrodeses restricted mainly internal-external rotation and inversion-eversion. The restriction in a double arthrodesis was more than that in a single arthrodesis, but that in a calcaneocuboid arthrodesis was relatively low. After triple arthrodeses, the restriction on dorsiflexion and plantarflexion movements was substantial, and internal-external rotation and inversion-eversion were almost lost. Considering that different arthrodesis procedures cause complex, three-dimensional hindfoot motion reductions, we recommend talonavicular or calcaneocuboid arthrodesis for patients with well-preserved functions of plantarflexion/dorsiflexion before operation, subtalar or calcaneocuboid arthrodesis for patients with well-preserved abduction/adduction, and talonavicular arthrodesis for patients with well-preserved eversion/inversion. PMID:27752084
Linearly Polarized Dual-Wavelength Vertical-External-Cavity Surface-Emitting Laser (Postprint)
2007-03-01
Lamb, Jr., Laser Physics Addison-Wesley, Reading, MA, 1974, pp. 125-126. 7A. E. Siegman , Lasers University Sciences Books, Sausalito, CA, 1986, pp...AFRL-RY-WP-TP-2008-1171 LINEARLY POLARIZED DUAL-WAVELENGTH VERTICAL-EXTERNAL-CAVITY SURFACE-EMITTING LASER (Postprint) Li Fan, Mahmoud...LINEARLY POLARIZED DUAL-WAVELENGTH VERTICAL-EXTERNAL- CAVITY SURFACE-EMITTING LASER (Postprint) 5a. CONTRACT NUMBER IN-HOUSE 5b. GRANT NUMBER 5c
Kondo, Hisami; Toyota, Hiroyasu; Kamiya, Takayuki; Yamashita, Kazunari; Hakomori, Tadashi; Imoto, Junko; Kimura, Shin-Ichiro; Iwao, Yasunori; Itai, Shigeru
2017-01-01
External lubrication is a useful method which reduces the adhesion of powder to punches and dies by spraying lubricants during the tableting process. However, no information is available on whether the tablets prepared using an external lubrication system can be applicable for a film coating process. In this study, we evaluated the adhesion force of the film coating layer to the surface of tablets prepared using an external lubrication method, compared with those prepared using internal lubrication method. We also evaluated wettability, roughness and lubricant distribution state on the tablet surface before film coating, and investigated the relationship between peeling of the film coating layer and these tablet surface properties. Increasing lubrication through the external lubrication method decreased wettability of the tablet surface. However, no change was observed in the adhesion force of the film coating layer. On the other hand, increasing lubrication through the internal lubrication method, decreased both wettability of the tablet surface and the adhesion force of the film coating layer. The magnesium stearate distribution state on the tablet surface was assessed using an X-ray fluorescent analyzer and lubricant agglomerates were observed in the case of the internal lubrication method. However, the lubricant was uniformly dispersed in the external lubrication samples. These results indicate that the distribution state of the lubricant affects the adhesion force of the film coating layer, and external lubrication maintained sufficient lubricity and adhesion force of the film coating layer with a small amount of lubricant.
Kajbafzadeh, Abdol-Mohammad; Zeinoddini, Atefeh; Ebadi, Maryam; Heidari, Reza; Tajalli, Afshin
2014-04-01
The purpose of the study is to describe our experience with the application of externalized double-J ureteral stent (DJUS) during pyeloplasty for correction of ureteropelvic junction obstruction (UPJO) in order to avoid cystoscopy for stent removal. Pyeloplasty was performed in 523 infants with UPJO using miniature pyeloplasty technique. After removing the obstructed segment, a 3-Fr. DJUS was placed into the ureter. In order to avoid cystoscopy for the removal of the stent, a feeding tube was passed through the skin and renal pelvis via a separate stab incision, connected to the DJUS and secured to the external body surface (skin), and the pyeloplasty was completed. The feeding tube along with the stent was removed after 3-4 weeks, respectively. Postoperative follow-up visits were performed 1, 3, and 6 months after the procedure. The mean operative time was 49 min (range 41-79). Patients were discharged after 17 ± 2 h (mean ± SD). No patient experienced bladder spasm or anticholinergic administration. Forty-four patients (8.4 %) experienced minor complications including non-febrile urinary tract infections and mild hematuria. No major complication including urinoma, leakage, and stent migration or displacement was observed during the follow-up period. Stent removal was tolerated by 99.8 % of patients in an outpatient setting with minimal discomfort without performing cystoscopy. Using external DJUS along with a pyelocutaneous stent extension during pyeloplasty is a safe, feasible, and beneficial technique. This technique resulted in high success rate with minimal cost and no renal injury. The non-cystoscopic stent removal and elimination of urethral catheterization following pyeloplasty are the other advantages of this technique.
Yin, Yueju; Sheng, Xiugui; Li, Xinglan; Li, Dapeng; Han, Xiaoyun; Zhang, Xiaoling; Zhang, Tingting
2014-06-01
The distal external iliac lymph nodes are located along the external iliac artery between the deep circumflex iliac vein and the inguinal canal. Our study aimed to investigate the incidence of metastasis in distal external iliac lymph nodes and its association with clinicopathological factors in patients with early stage cervical cancer, and to determine the role of distal external iliac lymph nodes dissection in the surgery. Five hundred and twenty-four patients with early stage cervical cancer underwent radical hysterectomy and bilateral pelvic lymphadenectomy in the Shandong Province Cancer Hospital between June 1995 and December 2011, and their clinicopathological features were analyzed retrospectively. Of the 524 patients, 124 (23.7%) had pelvic lymph node metastasis. The metastasis rates were 16.2% (85 of 524 patients) in the obturator lymph nodes, 12.2% (64 of 524 patients) in the internal and external iliac lymph nodes, 2.9% (15 of 524 patients) in the common iliac lymph nodes, 2.1% (11 of 524 patients) in the distal external iliac lymph nodes, and 1.7% (9 of 524 patients) in the para-aortic nodes. The incidence of isolated positive distal external iliac lymph nodes was 0.2%. Univariate analysis showed that lymphovascular space invasion, pelvic lymph node metastases (excluding distal external iliac lymph nodes) were significantly associated with distal external iliac lymph node metastasis (P < 0.05). Logistic regression analysis showed that pelvic lymph node metastasis (excluding distal external iliac lymph nodes) was the independent risk factor for metastasis to distal external iliac lymph nodes. In early stage cervical cancer, distal external iliac lymph node metastasis is rare, especially in cases with stage IA or without pelvic lymph node metastasis. Less extensive pelvic lymphadenectomy may be considered in these patients in order to reduce operative complications and improve patients' quality of life. The deep circumflex iliac vein may be an appropriate landmark for the caudal limit of external iliac lymphadenectomy. However, if pelvic lymph node metastasis (excluding distal external iliac lymph nodes) is found by intraoperative rapid pathological diagnosis, systematic pelvic lymphadenectomy including removal of the distal external iliac lymph nodes should be performed in order to reduce the risk of distant metastasis.
Calcium and initial surface binding phase of pinocytosis in Amoeba proteus.
Prusch, R D
1986-08-01
The uptake of membrane-bound solute and external medium by bulk-phase pinocytosis in Amoeba proteus is influenced by the level of Ca2+ in the external medium. Increasing external Ca2+ to approximately 10(-4) M increases pinocytotic intensity, while increases in Ca2+ above this level decrease the intensity of pinocytosis. The initial interaction of pinocytotic inducers and Ca2+ at the surface of Amoeba proteus was therefore examined. Alcian blue and Na+, both inducers of pinocytosis, differ in the manner with which they associate with the amoeba surface, suggesting the possibility of different pinocytosis-inducing sites on the amoeba surface. Low levels of external Ca2+ in the range of 3 X 10(-5) to 1.5 X 10(-4) M increase the amount of cationic inducer associated with the cell surface while, at the same time, decreasing anion association with the cell surface. It is suggested that Ca2+ influences ion association with the cell surface by controlling the availability of negative surface sites, which in turn influences pinocytotic intensity.
Li, Jia; Sun, Jin-Ke; Wang, Chen-Lin
2017-06-25
To investigate surgical skills and clinical effects of manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures. From May 2013 to October 2016, 35 patients with grade IV supination-external rotation ankle fractures were treated with percutaneous Kirschner wire internal fixation, involving 22 males and 13 females with an average age of 38.2 years ranged from 18 to 65 years old. The time from injury to operation ranged from 2 h to 10 d with an average of 5 d. Reduction quality was assessed by Burwell-Charnley radiological criteria. Baird-Jackson ankle scoring system was used to assess clinical effects. Thirty-three patients were followed up from 10 to 28 months with an average of 14 months. Fracture healing time ranged from 10 to 18 weeks with an average of 12 weeks. According to Burwell-Charnley radiological criteria, 30 cases were obtained anatomic reduction, 3 cases moderate. According to Baird-Jackson ankle scoring system, total score was 93.8±5.4, 17 cases got excellent result, 12 good, 2 fair and 2 poor. Manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures has advantages of reliable efficacy, less complications. But higher require techniques were required for closed reduction. It is not suitable for severe crushed fracture and compressive articular surface fracture.
Binnie, N R; Kawimbe, B M; Papachrysostomou, M; Clare, N; Smith, A N
1991-02-01
Two non-invasive anal plug electrodes of similar size have been compared, one with the electrode plates orientated circularly in the anal canal and the other with the plates in the long axis of the anal canal. There was a significant increase in the amplitude in the EMG signals recorded at rest and during squeeze from the external anal sphincter with a longitudinally placed electrode in 117 patients. Inappropriate contraction of the external anal sphincter when straining at stool was more readily detected using the longitudinal electrode in 52 patients investigated for intractable constipation. The longitudinal electrode detected the amplitude of the response to the elicitation of a pudeno-anal reflex more readily than the circular electrode. When in 12 of the 117 the pudeno-anal reflex EMG signal was either absent or not detected with the circumferential plug electrode, the longitudinal electrode detected the presence of a low amplitude response in 11 of these. When the non-invasive longitudinal electrode was compared to invasive fine wire stainless steel electrodes, a correlation was found for external anal sphincter resting EMG (r = 0.99, p less than 0.01), voluntary squeeze EMG (r = 0.99, p less than 0.001) and strain EMG (r = 0.91, p less than 0.01). The longitudinal anal plug electrode thus facilitates surface acquisition of EMG activity.
2015-07-16
SECURITY CLASSIFICATION OF: The InAs quantum dot (QD) grown on GaAs substrates represents a highly performance active region in the 1 - 1.3 µm...2015 Approved for Public Release; Distribution Unlimited Final Report: Mode-locking of an InAs Quantum Dot Based Vertical External Cavity Surface...ABSTRACT Final Report: Mode-locking of an InAs Quantum Dot Based Vertical External Cavity Surface Emitting Laser Using Atomic Layer Graphene Report
Regulation of oxygen vacancy types on SnO{sub 2} (110) surface by external strain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Z. H.; Min, Y. M.; Liu, X. X.
2016-05-15
In tin dioxide nanostructures, oxygen vacancies (OVs) play an important role in their optical properties and thus regulation of both OV concentration and type via external strain is crucial to exploration of more applications. First-principle calculations of SnO{sub 2} (110) surface disclose that asymmetric deformations induced by external strain not only lead to its intrinsic surface elastic changes, but also result in different OV formation energy. In the absence of external strain, the energetically favorable oxygen vacancies(EFOV) appear in the bridging site of second layer. When -3.5% external strain is applied along y direction, the EFOV moves into plane site.more » This can be ascribed that the compressed deformation gives rise to redistribution of electronic wave function near OVs, therefore, formation of newly bond structures. Our results suggest that different type OVs in SnO{sub 2} surface can be controlled by strain engineering.« less
NASA Astrophysics Data System (ADS)
Andreozzi, Jacqueline M.; Zhang, Rongxiao; Glaser, Adam K.; Gladstone, David J.; Jarvis, Lesley A.; Pogue, Brian W.
2016-03-01
External beam radiotherapy utilizes high energy radiation to target cancer with dynamic, patient-specific treatment plans. The otherwise invisible radiation beam can be observed via the optical Cherenkov photons emitted from interaction between the high energy beam and tissue. Using a specialized camera-system, the Cherenkov emission can thus be used to track the radiation beam on the surface of the patient in real-time, even for complex cases such as volumetric modulated arc therapy (VMAT). Two patients undergoing VMAT of the head and neck were imaged and analyzed, and the viability of the system to provide clinical feedback was established.
A dual-Kinect approach to determine torso surface motion for respiratory motion correction in PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heß, Mirco, E-mail: mirco.hess@uni-muenster.de; Büther, Florian; Dawood, Mohammad
2015-05-15
Purpose: Respiratory gating is commonly used to reduce blurring effects and attenuation correction artifacts in positron emission tomography (PET). Established clinically available methods that employ body-attached hardware for acquiring respiration signals rely on the assumption that external surface motion and internal organ motion are well correlated. In this paper, the authors present a markerless method comprising two Microsoft Kinects for determining the motion on the whole torso surface and aim to demonstrate its validity and usefulness—including the potential to study the external/internal correlation and to provide useful information for more advanced correction approaches. Methods: The data of two Kinects aremore » used to calculate 3D representations of a patient’s torso surface with high spatial coverage. Motion signals can be obtained for any position by tracking the mean distance to a virtual camera with a view perpendicular to the surrounding surface. The authors have conducted validation experiments including volunteers and a moving high-precision platform to verify the method’s suitability for providing meaningful data. In addition, the authors employed it during clinical {sup 18}F-FDG-PET scans and exemplarily analyzed the acquired data of ten cancer patients. External signals of abdominal and thoracic regions as well as data-driven signals were used for gating and compared with respect to detected displacement of present lesions. Additionally, the authors quantified signal similarities and time shifts by analyzing cross-correlation sequences. Results: The authors’ results suggest a Kinect depth resolution of approximately 1 mm at 75 cm distance. Accordingly, valid signals could be obtained for surface movements with small amplitudes in the range of only few millimeters. In this small sample of ten patients, the abdominal signals were better suited for gating the PET data than the thoracic signals and the correlation of data-driven signals was found to be stronger with abdominal signals than with thoracic signals (average Pearson correlation coefficients of 0.74 ± 0.17 and 0.45 ± 0.23, respectively). In all cases, except one, the abdominal respiratory motion preceded the thoracic motion—a maximum delay of approximately 600 ms was detected. Conclusions: The method provides motion information with sufficiently high spatial and temporal resolution. Thus, it enables meaningful analysis in the form of comparisons between amplitudes and phase shifts of signals from different regions. In combination with a large field-of-view, as given by combining the data of two Kinect cameras, it yields surface representations that might be useful in the context of motion correction and motion modeling.« less
Determining eyeball surface area directly exposed to the effects of external factors.
Juliszewski, Tadeusz; Kadłuczka, Filip; Kiełbasa, Paweł
2016-01-01
This article discusses determining the surface area of eyeballs of men and women exposed to the direct effects of external factors in the working environment. For one eye, the mean surface is 172-182 mm(2). The determined surface area can be used in formulas for calculating the exposure of eyeballs to harmful chemical substances in workplace air.
30 CFR 18.23 - Limitation of external surface temperatures.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction... external surfaces of mechanical or electrical components shall not exceed 150 °C. (302 °F.) under normal...
Management of rare, low anal anterior fistula exception to Goodsall's rule with Kṣārasūtra.
Shindhe, Pradeep S
2014-01-01
Anal fistula (bhagandara) is a chronic inflammatory condition, a tubular structure opening in the ano-rectal canal at one end and surface of perineum/peri-anal skin on the other end. Typically, fistula has two openings, one internal and other external associated with chronic on/off pus discharge on/off pain, pruritis and sometimes passing of stool from external opening. This affects predominantly male patients due to various etiologies viz., repeated peri-anal infections, Crohn's disease, HIV infection, etc., Complex and atypical variety is encountered in very few patients, which require special treatment for cure. The condition poses difficulty for a surgeon in treating due to issues like patient hesitation, trouble in preparing kṣārasūtra, natural and routine infection with urine, stool etc., and dearth of surgical experts and technique. We would like to report a complex and atypical, single case of anterior, low anal fistula with tract reaching to median raphe of scrotum, which was managed successfully by limited application of kṣārasūtra.
Anesthesia in patients with infectious disease caused by multi-drug resistant bacteria.
Einav, Sharon; Wiener-Well, Yonit
2017-06-01
Up to 50% of specific bacterial strains in healthcare admission facilities are multi-drug resistant organisms (MDROs). Involvement of anesthesiologists in management of patients carrying/at risk of carrying MDROs may decrease transmission in the Operating Room (OR). Anesthesiologists, their work area and tools have all been implicated in MDRO outbreaks. Causes include contamination of external ventilation circuits and noncontribution of filters to prevention, inappropriate decontamination procedures for nondisposable equipment (e.g. laryngoscopes, bronchoscopes and stethoscopes) and the anesthesia workplace (e.g. external surfaces of cart and anesthesia machine, telephones and computer keyboards) during OR cleaning and lack of training in sterile drug management. Discussions regarding the management of potential MDRO carriers must include anesthesia providers to optimize infection control interventions as well as the anesthesia method, the location of surgery and recovery and the details of patient transport. Anesthesia staff must learn to identify patients at risk for MDRO infection. Antibiotic prophylaxis, although not evidence based, should adhere to known best practices. Adjuvant therapies (e.g. intranasal Mupirocin and bathing with antiseptics) should be considered. Addition of nonmanual OR cleaning methods such as ultraviolet irradiation or gaseous decontamination is encouraged. Anesthesiologists must undergo formal training in sterile drug preparation and administration.
Sankaridurg, P R; Willcox, M D; Sharma, S; Gopinathan, U; Janakiraman, D; Hickson, S; Vuppala, N; Sweeney, D F; Rao, G N; Holden, B A
1996-01-01
Ten episodes of adverse responses to contact lens wear, including contact lens-induced acute red eye (CLARE), in which Haemophilus influenzae was isolated from contact lenses and/or from one of the external ocular sites at the time of the event, are described. All episodes occurred in patients wearing disposable hydrogel lenses on a 6-night extended-wear schedule. Two of the patients had recurrent episodes. H. influenzae was usually isolated in large numbers, and other bacteria or fungi colonizing the contact lens or the external ocular surface were usually present in low numbers. Those patients who were colonized with H. influenzae were more than 100 times as likely to have had a CLARE or infiltrative response than those subjects who were not colonized with this bacterium. H. influenzae colonization of the contact lens and eye may be subsequent to colonization of the nasopharynx because four of the seven patients presented with fever at the time of the event, with concurrent upper respiratory tract infection. Contact lens wearers should be made aware of the potential risk of CLARE associated with the wearing of contact lenses for extended periods during and subsequent to upper respiratory tract infection. PMID:8880493
Multimodality localization of epileptic foci
NASA Astrophysics Data System (ADS)
Desco, Manuel; Pascau, Javier; Pozo, M. A.; Santos, Andres; Reig, Santiago; Gispert, Juan D.; Garcia-Barreno, Pedro
2001-05-01
This paper presents a multimodality approach for the localization of epileptic foci using PET, MRI and EEG combined without the need of external markers. Mutual Information algorithm is used for MRI-PET registration. Dipole coordinates (provided by BESA software) are projected onto the MRI using a specifically developed algorithm. The four anatomical references used for electrode positioning (nasion, inion and two preauricular points) are located on the MRI using a triplanar viewer combined with a surface-rendering tool. Geometric transformation using deformation of the ideal sphere used for dipole calculations is then applied to match the patient's brain size and shape. Eight treatment-refractory epileptic patients have been studied. The combination of the anatomical information from the MRI, hipoperfusion areas in PET and dipole position and orientation helped the physician in the diagnosis of epileptic focus location. Neurosurgery was not indicated for patients where PET and dipole results were inconsistent; in two cases it was clinically indicated despite the mismatch, showing a negative follow up. The multimodality approach presented does not require external markers for dipole projection onto the MRI, this being the main difference with previous methods. The proposed method may play an important role in the indication of surgery for treatment- refractory epileptic patients.
Bone scanning in severe external otitis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levin, W.J.; Shary, J.H. 3d.; Nichols, L.T.
1986-11-01
Technetium99 Methylene Diphosphate bone scanning has been considered an early valuable tool to diagnose necrotizing progressive malignant external otitis. However, to our knowledge, no formal studies have actually compared bone scans of otherwise young, healthy patients with severe external otitis to scans of patients with clinical presentation of malignant external otitis. Twelve patients with only severe external otitis were studied with Technetium99 Diphosphate and were compared to known cases of malignant otitis. All scans were evaluated by two neuroradiologists with no prior knowledge of the clinical status of the patients. Nine of the 12 patients had positive bone scans withmore » many scans resembling those reported with malignant external otitis. Interestingly, there was no consistent correlation between the severity of clinical presentation and the amount of Technetium uptake. These findings suggest that a positive bone scan alone should not be interpreted as indicative of malignant external otitis.« less
Phononic crystal diffraction gratings
NASA Astrophysics Data System (ADS)
Moiseyenko, Rayisa P.; Herbison, Sarah; Declercq, Nico F.; Laude, Vincent
2012-02-01
When a phononic crystal is interrogated by an external source of acoustic waves, there is necessarily a phenomenon of diffraction occurring on the external enclosing surfaces. Indeed, these external surfaces are periodic and the resulting acoustic diffraction grating has a periodicity that depends on the orientation of the phononic crystal. This work presents a combined experimental and theoretical study on the diffraction of bulk ultrasonic waves on the external surfaces of a 2D phononic crystal that consists of a triangular lattice of steel rods in a water matrix. The results of transmission experiments are compared with theoretical band structures obtained with the finite-element method. Angular spectrograms (showing frequency as a function of angle) determined from diffraction experiments are then compared with finite-element simulations of diffraction occurring on the surfaces of the crystal. The experimental results show that the diffraction that occurs on its external surfaces is highly frequency-dependent and has a definite relation with the Bloch modes of the phononic crystal. In particular, a strong influence of the presence of bandgaps and deaf bands on the diffraction efficiency is found. This observation opens perspectives for the design of efficient phononic crystal diffraction gratings.
Thiel, M; Bossart, W; Bernauer, W
1997-01-01
BACKGROUND—For epidemiological and therapeutic reasons early diagnosis of superficial viral infections is crucial. Conventional microbiological techniques are expensive, time consuming, and not sufficiently sensitive. In this study impression cytology techniques were evaluated to analyse their diagnostic potential in viral infections of the ocular surface. METHOD—A Biopore membrane device instead of the original impression cytology technique was used to allow better quality and handling of the specimens. The impressions were processed, using monoclonal antibodies and immunoperoxidase or immunofluorescence techniques to assess the presence of herpes simplex virus, varicella zoster virus, or adenovirus antigens. Ocular surface specimens from healthy individuals (n=10) and from patients with suspected viral surface disease (n=19) were studied. Infected and non-infected cell cultures served as controls. RESULTS—This modified technique of impression cytology allowed the collection of large conjunctival and corneal epithelial cell layers with excellent morphology. Immunocytological staining of these samples provided diagnostic results for all three viruses in patients with viral surface disease. CONCLUSIONS—The use of Biopore membrane devices for the collection of ocular surface epithelia offers new diagnostic possibilities for external eye diseases. Immunopathological methods that are applied directly on these membrane devices can provide virological results within 1-4 hours. This contributes considerably to the clinical management of patients with infectious diseases of the ocular surface. PMID:9505824
Calcium and initial surface binding phase of pinocytosis in Amoeba proteus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prusch, R.D.
1986-08-01
The uptake of membrane-bound solute and external medium by bulk-phase pinocytosis in Amoeba proteus is influenced by the level of Ca/sup 2 +/ in the external medium. Increasing external Ca/sup 2 +/ to approx.10/sup -4/ M increases pinocytotic intensity, while increases in Ca/sup 2 +/ above this level decrease the intensity of pinocytosis. The initial interaction of pinocytotic inducers and Ca/sup +2/ at the surface of A moeba proteus was therefore examined. Alcain blue and Na/sup +/, both inducers of pinocytosis, differ in the manner with which they associate with the amoeba surface, suggesting the possibility of different pinocytosis-inducing sitesmore » on the amoeba surface. Low levels of external Ca/sup 2 +/ in the range of 3 x 10/sup -5/ to 4.5 x 10/sup -4/ M increase the amount of cationic inducer associated with the cell surface while, at the same time, decreasing anion association with the cell surface. It is suggested that Ca/sup 2 +/ influences ion association with the cell surface by controlling the availability of negative surface sites, which in turn influences pinocytotic intensity. Surface binding of Na/sup +/, Ca/sup 2 +/ and Cl/sup -/ was determined by adding /sup 22/Na, /sup 45/Ca or /sup 36/Cl.« less
Affective modulation of external misattribution bias in source monitoring in schizophrenia.
Costafreda, S G; Brébion, G; Allen, P; McGuire, P K; Fu, C H Y
2008-06-01
Schizophrenic patients tend to attribute internal events to external agents, a bias that may be linked to positive symptoms. We investigated the effect of emotional valence on the cognitive bias. Male schizophrenic subjects (n=30) and an experimenter alternatively produced neutral and negative words. The subject then decided whether he or the experimenter had generated the item. External misattributions were more common than self-misattributions, and the bias was greater for patients with active hallucinations and delusions relative to patients in remission. Actively psychotic patients but not patients in remission were more likely to generate external misattributions with negative relative to neutral words. Affective modulation of the externalizing cognitive bias in source monitoring is evident in patients with hallucinations and delusions.
Tsukada, Yuichiro; Ito, Masaaki; Watanabe, Kentaro; Yamaguchi, Kumiko; Kojima, Motohiro; Hayashi, Ryuichi; Akita, Keiichi; Saito, Norio
2016-05-01
Intersphincteric resection has become a widely used treatment for patients with rectal cancer. However, the detailed anatomy of the anal canal related to this procedure has remained unclear. The purpose of this study was to clarify the detailed anatomy of the anal canal. This is a descriptive study. Histologic evaluations of paraffin-embedded tissue specimens were conducted at a tertiary referral hospital. Tissue specimens were obtained from cadavers of 5 adults and from 13 patients who underwent abdominoperineal resection for rectal cancer. Sagittal sections from 9 circumferential portions of the cadaveric anal canal (histologic staining) and 3 circumferential portions from patients were studied (immunohistochemistry for smooth and skeletal muscle fibers). Longitudinal fibers between the internal and external anal sphincters consisted primarily of smooth muscle fibers that continued from the longitudinal muscle of the rectum. The levator ani muscle attached directly to the lateral surface of the longitudinal smooth muscle of the rectum. The length of the attachment was longer in the anterolateral portion and shorter in the posterior portion of the anal canal. In the lateral and posterior portions, the levator ani muscle partially overlapped the external anal sphincter; however, there was less overlap in the anterolateral portion. In the posterior portion, thick smooth muscle was present on the surface of the levator ani muscle and it continued to the longitudinal muscle of the rectum. We observed only limited portions in some surgical specimens because of obstruction by tumors. The levator ani muscle attaches directly to the longitudinal muscle of the rectum. The spatial relationship between the smooth and skeletal muscles differed in different portions of the anal canal. For intersphincteric resection, dissection must be performed between the longitudinal muscle of the rectum and the levator ani muscle/external anal sphincter, and the appropriate surgical lines must be selected based on the specific structural characteristics of each portion.
NASA Astrophysics Data System (ADS)
Arenas, Mónica P.; Silveira, Rosa M.; Pacheco, Clara J.; Bruno, Antonio C.; Araujo, Jefferson F. D. F.; Eckstein, Carlos B.; Nogueira, Laudemiro; de Almeida, Luiz H.; Rebello, João M. A.; Pereira, Gabriela R.
2018-06-01
Heat-resistant austenitic stainless steels have become the principal alloys for use in steam reformer tubes in the petrochemical industry due to its mechanical properties. These tubes are typically exposed to severe operational conditions leading to microstructural transformations such as the aging phenomenon. The combination of high temperatures and moderate stresses causes creep damages, being necessary to monitor its structural condition by non-destructive techniques. The tube external wall is also subjected to oxidizing atmospheres, favoring the formation of an external surface, composed by an oxide scale and a chromium depleted zone. This external surface is usually not taken into account in the tube evaluation, which can lead to erroneous estimations of the service life of these components. In order to observe the magnetic influence of this layer, two samples, exposed to different operational temperatures, were characterized by non-destructive eddy current testing (ECT), scanning DC-susceptometer and magnetic force microscopy (MFM). It was found that the external surface thickness influences directly in the magnetic response of the samples.
Piezosurgery in External Dacryocystorhinostomy.
Czyz, Craig N; Fowler, Amy M; Dutton, Jonathan J; Cahill, Kenneth V; Foster, Jill A; Hill, Robert H; Everman, Kelly R; Nabavi, Cameron B
Dacryocystorhinostomy (DCR) can be performed via an external or endoscopic approach. The use of ultrasonic or piezosurgery has been well described for endoscopic DCRs but is lacking for external DCRs. This study presents a case series of external DCRs performed using piezosurgery evaluating results and complications. Prospective, consecutive case series of patients undergoing primary external DCR for lacrimal drainage insufficiency. A standard external DCR technique was used using 1 of 2 piezosurgery systems for all bone incision. All patients received silicone intubation to the lacrimal system. Surgical outcome was measured in terms of patient-reported epiphora as follows: 1) complete resolution, 2) improvement >50%, 3) improvement <50%, and 4) No improvement. Intra and postoperative complications were also recorded. Fifty-two patients, 14 male and 38 female, were included in the study, with 2 patients having bilateral surgery. The average age of the patients was 55.8 years. The average length of follow up was 221 days. Surgical outcomes showed 72% of patients with complete resolution of epiphora and 21% with >50% improvement. There were 4 patients (7%) who had <50% improvement. There was 1 (2%) intraoperative complication and 2 (4%) postoperative complications recorded. Piezourgery is a viable modality for performing external DCRs. The lack of surgical complications shows a potential for decreased soft tissues damage. The surgical success rate based on patient-reported epiphora is similar to those published for mechanical external DCRs. This modality may benefit the novice surgeon in the reduction of soft and mucosal tissue damage.
2009-01-01
The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. Patients and Methods From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Results: Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Conclusion Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations. PMID:19258207
Shah, Nirav G.; Cowan, Mark J.; Pickering, Edward; Sareh, Houtan; Afshar, Majid; Fox, Dawn; Marron, Jennifer; Davis, Jennifer; Herold, Keith; Shanholtz, Carl B.; Hasday, Jeffrey D.
2012-01-01
Purpose This study had two objectives: (1) to quantify the metabolic response to physical cooling in febrile patients with Systemic Inflammatory Response Syndrome (SIRS); and (2) to provide proof for the hypothesis that the efficiency of external cooling and the subsequent shivering response are influenced by site and temperature of surface cooling pads. Methods To quantify shivering thermogenesis during surface cooling for fever, we monitored oxygen consumption (VO2) in six febrile patients with SIRS during conventional cooling with cooling blankets and ice packs. To begin to determine how location and temperature of surface cooling influences shivering, we compared 5 cooling protocols for inducing mild hypothermia in six healthy volunteers. Results In the SIRS patients, core temperature decreased 0.67°C per hour, all patients shivered, VO2 increased 57.6% and blood pressure increased 15% during cooling. In healthy subjects, cooling with the 10°C vest was most comfortable and removed heat most efficiently without shivering or VO2 increase. Cooling with combined vest and thigh pads stimulated the most shivering and highest VO2, and increased core temperature. Reducing vest temperature from 10°C to 5°C failed to increase heat removal secondary to cutaneous vasoconstriction. Capsaicin, an agonist for TRPV1 warm-sensing channels, partially reversed this effect in 5 subjects. Conclusions Our results identify the hazards of surface cooling in febrile critically ill patients and support the concept that optimization of cooling pad temperature and position may improve cooling efficiency and reduce shivering. PMID:22762936
Shah, Nirav G; Cowan, Mark J; Pickering, Edward; Sareh, Houtan; Afshar, Majid; Fox, Dawn; Marron, Jennifer; Davis, Jennifer; Herold, Keith; Shanholtz, Carl B; Hasday, Jeffrey D
2012-12-01
This study had 2 objectives: (1) to quantify the metabolic response to physical cooling in febrile patients with systemic inflammatory response syndrome (SIRS) and (2) to provide proof for the hypothesis that the efficiency of external cooling and the subsequent shivering response are influenced by site and temperature of surface cooling pads. To quantify shivering thermogenesis during surface cooling for fever, we monitored oxygen consumption (VO(2)) in 6 febrile patients with SIRS during conventional cooling with cooling blankets and ice packs. To begin to determine how location and temperature of surface cooling influence shivering, we compared 5 cooling protocols for inducing mild hypothermia in 6 healthy volunteers. In the patients with SIRS, core temperature decreased 0.67 °C per hour, all patients shivered, VO(2) increased 57.6%, and blood pressure increased 15% during cooling. In healthy subjects, cooling with the 10 °C vest was most comfortable and removed heat most efficiently without shivering or VO(2) increase. Cooling with combined vest and thigh pads stimulated the most shivering and highest VO(2) and increased core temperature. Reducing vest temperature from 10 °C to 5 °C failed to increase heat removal secondary to cutaneous vasoconstriction. Capsaicin, an agonist for the transient receptor potential cation channel subfamily V member 1 (TRPV1) warm-sensing channels, partially reversed this effect in 5 subjects. Our results identify the hazards of surface cooling in febrile critically ill patients and support the concept that optimization of cooling pad temperature and position may improve cooling efficiency and reduce shivering. Copyright © 2012 Elsevier Inc. All rights reserved.
Campana, Lorenzo; Breitbeck, Robert; Bauer-Kreuz, Regula; Buck, Ursula
2016-05-01
This study evaluated the feasibility of documenting patterned injury using three dimensions and true colour photography without complex 3D surface documentation methods. This method is based on a generated 3D surface model using radiologic slice images (CT) while the colour information is derived from photographs taken with commercially available cameras. The external patterned injuries were documented in 16 cases using digital photography as well as highly precise photogrammetry-supported 3D structured light scanning. The internal findings of these deceased were recorded using CT and MRI. For registration of the internal with the external data, two different types of radiographic markers were used and compared. The 3D surface model generated from CT slice images was linked with the photographs, and thereby digital true-colour 3D models of the patterned injuries could be created (Image projection onto CT/IprojeCT). In addition, these external models were merged with the models of the somatic interior. We demonstrated that 3D documentation and visualization of external injury findings by integration of digital photography in CT/MRI data sets is suitable for the 3D documentation of individual patterned injuries to a body. Nevertheless, this documentation method is not a substitution for photogrammetry and surface scanning, especially when the entire bodily surface is to be recorded in three dimensions including all external findings, and when precise data is required for comparing highly detailed injury features with the injury-inflicting tool.
Nakata, K; Inoue, Y; Harada, J; Maeda, N; Watanabe, H; Tano, Y; Shimomura, Y; Harino, S; Sawa, M
2000-12-01
To determine the frequency distribution of bacteria on the external surface of eyes of patients with atopic dermatitis (AD) and to investigate the relationship between the frequency of bacterial colonization and the grade of atopy or ocular diseases associated with AD. Comparative cross-sectional study. Thirty-six AD patients (mean age, 24.5 years) and 16 nonatopic, age-matched control participants (mean age, 25.5 years). The eyelid margins and conjunctival sacs were scraped with sterile swabs. These samples were inoculated into aerobic and anaerobic culture media. The frequency distribution of bacteria isolated from the eyelid margins and conjunctival sacs. Bacteria isolated from AD patients were: Staphylococcus aureus in 21 of 36 patients (including methicillin-resistant Staphylococcus aureus in two patients); Staphylococcus epidermidis in two patients (including methicillin-resistant Staphylococcus epidermidis in one patient); other coagulase-negative Staphylococcus in six patients;alpha-streptococcus in three patients; Corynebacterium species in three patients; Neisseria species in two patients; and Propionibacterium acnes in one patient. From the nonatopic control participants, we isolated S. aureus in one patient, S. epidermidis in two patients and alpha-streptococcus in one patient. S. aureus was isolated from 67% of the AD patients, and any type of bacteria was isolated from 86% of the patients. These rates were significantly higher than those of nonatopic control participants (6% S. aureus and 25% any bacteria). There was no significant relationship between the frequency distribution of bacteria and the grade of atopy or associated ocular diseases. High rates of bacterial colonization, especially S. aureus, were found in the conjunctival sacs and eyelid margins of AD patients. In case management of AD patients, this unique distribution of bacteria must be carefully considered.
Extension of Gibbs-Duhem equation including influences of external fields
NASA Astrophysics Data System (ADS)
Guangze, Han; Jianjia, Meng
2018-03-01
Gibbs-Duhem equation is one of the fundamental equations in thermodynamics, which describes the relation among changes in temperature, pressure and chemical potential. Thermodynamic system can be affected by external field, and this effect should be revealed by thermodynamic equations. Based on energy postulate and the first law of thermodynamics, the differential equation of internal energy is extended to include the properties of external fields. Then, with homogeneous function theorem and a redefinition of Gibbs energy, a generalized Gibbs-Duhem equation with influences of external fields is derived. As a demonstration of the application of this generalized equation, the influences of temperature and external electric field on surface tension, surface adsorption controlled by external electric field, and the derivation of a generalized chemical potential expression are discussed, which show that the extended Gibbs-Duhem equation developed in this paper is capable to capture the influences of external fields on a thermodynamic system.
Kim, Moon-Hwan; Oh, Jae-Seop
2015-01-01
[Purpose] The purpose of this study was to examine the effects of humeral head compression taping (HHCT) on the strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis. [Subjects and Methods] Twenty patients with rotator cuff tendinitis were recruited. The shoulder external rotator strength was measured using a Biodex isokinetic dynamometer system. A paired t-test was performed to evaluate within-group differences in the strength of the shoulder external rotator muscle. [Results] Significantly higher shoulder external rotator peak torque and peak torque per body weight were found in the HHCT condition than in the no-taping condition. [Conclusion] HHCT may effectively increase the shoulder external rotator muscle strength in patients with rotator cuff tendinitis.
Curvature Dependent Reactivity of Fullerenes and Nanotubes
NASA Technical Reports Server (NTRS)
Park, Seongjun; Cho, Kyeongjae; Srivastava, Deepak
2000-01-01
Dependence of pyramidalization angle, examples of nanotube surfaces, internal and external reactivity, and binding energies are some of the topics discussed in this conference presentation preprint. Final conclusions include the relationship between the pyramidal angle of the surface and its associated external reaction energy.
Soft-tissue reactions following irradiation of primary brain and pituitary tumors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baglan, R.J.; Marks, J.E.
1981-04-01
One hundred and ninety-nine patients who received radiation therapy for a primary brain or pituitary tumor were studied for radiation-induced soft-tissue reactions of the cranium, scalp, ears and jaw. The frequency of these reactions was studied as a function of: the radiation dose 5 mm below the skin surface, dose distribution, field size and fraction size. Forty percent of patients had complete and permanent epilation, while 21% had some other soft-tissue complication, including: scalp swelling-6%, external otitis-6%, otitis media-5%, ear swelling-4%, etc. The frequency of soft-tissue reactions correlates directly with the radiation dose at 5 mm below the skin surface.more » Patients treated with small portals (<70 cm/sup 2/) had few soft-tissue reactions. The dose to superficial tissues, and hence the frequency of soft-tissue reactions can be reduced by: (1) using high-energy megavoltage beams; (2) using equal loading of beams; and (3) possibly avoiding the use of electron beams.« less
Blom, R L G M; Vliegen, R F A; Schreurs, W M J; Belgers, H J; Stohr, I; Oostenbrug, L E; Sosef, M N
2012-08-01
One of the objectives of preoperative imaging in esophageal cancer patients is the detection of cervical lymph node metastases. Traditionally, external ultrasonography of the neck has been combined with computed tomography (CT) in order to improve the detection of cervical metastases. In general, integrated positron emission tomography-computed tomography (PET-CT) has been shown to be superior to CT or PET regarding staging and therefore may limit the role of external ultrasonography of the neck. The objective of this study was to determine the additional value of external ultrasonography of the neck to PET-CT. This study included all patients referred our center for treatment of esophageal carcinoma. Diagnostic staging was performed to determine treatment plan. Cervical lymph nodes were evaluated by external ultrasonography of the neck and PET-CT. In case of suspect lymph nodes on external ultrasonography or PET-CT, fine needle aspiration (FNA) was performed. Between 2008 and 2010, 170 out of 195 referred patients underwent both external ultrasonography of the neck and PET-CT. Of all patients, 84% were diagnosed with a tumor at or below the distal esophagus. In 140 of 170 patients, the cervical region was not suspect; no FNA was performed. Seven out of 170 patients had suspect nodes on both PET-CT and external ultrasonography. Five out of seven patients had cytologically confirmed malignant lymph nodes, one of seven had benign nodes, in one patient FNA was not performed; exclusion from esophagectomy was based on intra-abdominal metastases. In one out of 170 patients, PET-CT showed suspect nodes combined with a negative external ultrasonography; cytology of these nodes was benign. Twenty-two out of 170 patients had a negative PET-CT with suspect nodes on external ultrasonography. In 18 of 22 patients, cervical lymph nodes were cytologically confirmed benign; in four patients, FNA was not possible or inconclusive. At a median postoperative follow-up of 15 months, only 1% of patients developed cervical lymph node metastases. This study shows no additional value of external ultrasonography to a negative PET-CT. According to our results, it can be omitted in the primary workup. However, suspect lymph nodes on PET-CT should be confirmed by FNA to exclude false positives if it would change treatment plan. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
Plasma-catalyzed fuel reformer
Hartvigsen, Joseph J.; Elangovan, S.; Czernichowski, Piotr; Hollist, Michele
2013-06-11
A reformer is disclosed that includes a plasma zone to receive a pre-heated mixture of reactants and ionize the reactants by applying an electrical potential thereto. A first thermally conductive surface surrounds the plasma zone and is configured to transfer heat from an external heat source into the plasma zone. The reformer further includes a reaction zone to chemically transform the ionized reactants into synthesis gas comprising hydrogen and carbon monoxide. A second thermally conductive surface surrounds the reaction zone and is configured to transfer heat from the external heat source into the reaction zone. The first thermally conductive surface and second thermally conductive surface are both directly exposed to the external heat source. A corresponding method and system are also disclosed and claimed herein.
Stability comparison between commercially available mini-implants and a novel design: part 1.
Hong, Christine; Lee, Haofu; Webster, Richard; Kwak, Jinny; Wu, Benjamin M; Moon, Won
2011-07-01
To compare mechanical stability among five mini-implant designs--a newly invented design and four commercially available designs that vary by shape and threading; to calculate external surface area of each design using high-resolution micro-computed tomography; and to evaluate the relationship between surface area and stability results. The four commercially available mini-implants--single-threaded and cylindrical (SC), single-threaded and tapered (ST), double-threaded and cylindrical (DC), double-threaded and tapered (DT)--and a new implant that is designed to engage mostly in cortical bone with shorter and wider dimensions (N1) were inserted in simulated bone with cortical and trabecular bone layers. The mechanical study consisted of torque measurements and lateral displacement tests. External surface area was computed using a 25-µm micro-CT. Maximum insertion torque, maximum removal torque, and force levels for displacements were the highest in N1, followed by DT, ST, DC, and SC (α = .05). The surface area was largest in DT, followed by N1, ST, DC, and SC. Surface area engaged in cortical bone, however, was the greatest in N1. The surface area of mini-implants had positive correlation with stability. Among commercial designs, both added tapering and double threading improved stability. N1 was the most stable design within this research design. The new design has the potential to be clinically superior; it has enhanced stability and there is diminished risk of endangering nearby anatomic structures during placement and orthodontic treatment, but the design requires refinements to reduce insertion torque to avoid clinical difficulty and patient discomfort.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dutta, Akshita; Tymi?ska, Nina; Zhu, Guanghui
In this paper, the interaction between hydrogen sulfide and ZIF-8 was studied via structural characterizations and guest molecule diffusion measurements. It was found that hydrogen sulfide reacts with the ZIF-8 external particle surface to form a surface barrier that excludes the uptake of larger molecules (ethanol) and slows down the uptake of smaller molecules (carbon dioxide). Nonetheless, bulk transport properties were unaltered, as supported by pulsed field gradient nuclear magnetic resonance studies. Dispersion-corrected density functional theory calculations revealed that H 2S is consumed by reactions occurring at the ZIF external surface. These reactions result in water and defect formation, bothmore » of which were found to be exothermic and independent of both crystallographic facets ({001} and {110}) and surface termination. Finally, we concluded that these surface reactions lead to structural and chemical changes to the ZIF-8 external surface that generate surface barriers to molecular transport.« less
Dutta, Akshita; Tymi?ska, Nina; Zhu, Guanghui; ...
2018-03-09
In this paper, the interaction between hydrogen sulfide and ZIF-8 was studied via structural characterizations and guest molecule diffusion measurements. It was found that hydrogen sulfide reacts with the ZIF-8 external particle surface to form a surface barrier that excludes the uptake of larger molecules (ethanol) and slows down the uptake of smaller molecules (carbon dioxide). Nonetheless, bulk transport properties were unaltered, as supported by pulsed field gradient nuclear magnetic resonance studies. Dispersion-corrected density functional theory calculations revealed that H 2S is consumed by reactions occurring at the ZIF external surface. These reactions result in water and defect formation, bothmore » of which were found to be exothermic and independent of both crystallographic facets ({001} and {110}) and surface termination. Finally, we concluded that these surface reactions lead to structural and chemical changes to the ZIF-8 external surface that generate surface barriers to molecular transport.« less
Kal, Elmar; van den Brink, Henrieke; Houdijk, Han; van der Kamp, John; Goossens, Paulien Helena; van Bennekom, Coen; Scherder, Erik
2018-05-01
People without neurological impairments show superior motor learning when they focus on movement effects (external focus) rather than on movement execution itself (internal focus). Despite its potential for neurorehabilitation, it remains unclear to what extent external focus strategies are currently incorporated in rehabilitation post-stroke. Therefore, we observed how physical therapists use attentional focus when treating gait of rehabilitating patients with stroke. Twenty physical therapist-patient couples from six rehabilitation centers participated. Per couple, one regular gait-training session was video-recorded. Therapists' statements were classified using a standardized scoring method to determine the relative proportion of internally and externally focused instructions/feedback. Also, we explored associations between therapists' use of external/internal focus strategies and patients' focus preference, length of stay, mobility, and cognition. Therapists' instructions were generally more external while feedback was more internal. Therapists used relatively more externally focused statements for patients with a longer length of stay (B = -0.239, p = 0.013) and for patients who had a stronger internal focus preference (B = -0.930, p = 0.035). Physical therapists used more external focus instructions, but more internally focused feedback. Also, they seem to adapt their attentional focus use to patients' focus preference and rehabilitation phase. Future research may determine how these factors influence the effectiveness of different attentional foci for motor learning post-stroke. IMPLICATIONS FOR REHABILITATION Physical therapists use a balanced mix of internal focus and external focus instructions and feedback when treating gait of stroke patients. Therapists predominantly used an external focus for patients in later rehabilitation phases, and for patients with stronger internal focus preferences, possibly in an attempt to stimulate more automatic control of movement in these patients. Future research should further explore how a patients' focus preference and rehabilitation phase influence the effectiveness of different focus strategies. Awaiting further research, we recommend that therapists use both attentional focus strategies, and explore per patient which focus works best on a trial-and-error basis.
NASA Astrophysics Data System (ADS)
He, Lijie; Langlet, Michel; Stambouli, Valerie
2017-03-01
The conformation and topological properties of DNA single strand probe molecules attached on solid surfaces are important, notably for the performances of devices such as biosensors. Commonly, the DNA probes are tethered to the surface using external linkers such as NH2. In this study, the role and influence of this amino-linker on the immobilization way and conformation of DNA probes on Ag nanoparticle surface is emphasized using Surface Enhanced Raman Spectroscopy (SERS). We compare the SERS spectra and their reproducibility in the case of two groups of DNA polybase probes which are polyA, polyC, polyT, and polyG. In the first group, the polybases exhibit an external NH2 functional linker while in the second group the polybases are NH2-free. The results show that the reproducibility of SERS spectra is enhanced in the case of the first group. It leads us to propose two models of polybase conformation on Ag surface according to the presence or the absence of the external NH2 linker. In the presence of the NH2 external linker, the latter would act as a major anchoring point. As a result, the polybases are much ordered with a less random orientation than in the case of NH2-free polybases. Consequently, in view of further in situ hybridization for biosensing applications, it is strongly recommended to use NH2 linker functionalized DNA probes.
NASA Astrophysics Data System (ADS)
Al-Mayah, Adil; Moseley, Joanne; Hunter, Shannon; Brock, Kristy
2015-11-01
Biomechanical-based deformable image registration is conducted on the head and neck region. Patient specific 3D finite element models consisting of parotid glands (PG), submandibular glands (SG), tumor, vertebrae (VB), mandible, and external body are used to register pre-treatment MRI to post-treatment MR images to model the dose response using image data of five patients. The images are registered using combinations of vertebrae and mandible alignments, and surface projection of the external body as boundary conditions. In addition, the dose response is simulated by applying a new loading technique in the form of a dose-induced shrinkage using the dose-volume relationship. The dose-induced load is applied as dose-induced shrinkage of the tumor and four salivary glands. The Dice Similarity Coefficient (DSC) is calculated for the four salivary glands, and tumor to calculate the volume overlap of the structures after deformable registration. A substantial improvement in the registration is found by including the dose-induced shrinkage. The greatest registration improvement is found in the four glands where the average DSC increases from 0.53, 0.55, 0.32, and 0.37 to 0.68, 0.68, 0.51, and 0.49 in the left PG, right PG, left SG, and right SG, respectively by using bony alignment of vertebrae and mandible (M), body (B) surface projection and dose (D) (VB+M+B+D).
Postural compensation for vestibular loss and implications for rehabilitation.
Horak, Fay B
2010-01-01
This chapter summarizes the role of the vestibular system in postural control so that specific and effective rehabilitation can be designed that facilitates compensation for loss of vestibular function. Patients with bilateral or unilateral loss of peripheral vestibular function are exposed to surface perturbations to quantify automatic postural responses. Studies also evaluated the effects of audio- and vibrotactile-biofeedback to improve stability in stance and gait. The most important role of vestibular information for postural control is to control orientation of the head and trunk in space with respect to gravitoinertial forces, particularly when balancing on unstable surfaces. Vestibular sensory references are particularly important for postural control at high frequencies and velocities of self-motion, to reduce trunk drift and variability, to provide an external reference frame for the trunk and head in space; and to uncouple coordination of the trunk from the legs and the head-in-space from the body CoM. The goal of balance rehabilitation for patients with vestibular loss is to help patients 1) use remaining vestibular function, 2) depend upon surface somatosensory information as their primary postural sensory system, 3) learn to use stable visual references, and 4) identify efficient and effective postural movement strategies.
Gil, Francisco Javier; Aparicio, Conrado; Manero, Jose M; Padros, Alejandro
2009-01-01
This study evaluated the effect of external hexagon height and commonly applied surface treatments on the fatigue life of titanium dental implants. Electropolished commercially pure titanium dental implants (seven implants per group) with three different external hexagon heights (0.6, 1.2, and 1.8 mm) and implants with the highest external hexagon height (1.8 mm) and different surface treatments (electropolishing, grit blasting with aluminium oxide, and acid etching with sulfuric acid) were tested to evaluate their mechanical fatigue life. To do so, 10-Hz triangular flexural load cycles were applied at 37 degrees C in artificial saliva, and the number of load cycles until implant fracture was determined. Tolerances of the hexagon/abutment fit and implant surface roughness were analyzed by scanning electron microscopy and light interferometry. Transmission electron microscopy and electron diffraction analyses of titanium hydrides were performed. First, the fatigue life of implants with the highest hexagon (8,683 +/- 978 load cycles) was more than double that of the implants with the shortest hexagons (3,654 +/- 789 load cycles) (P < .02). Second, the grit-blasted implants had the longest fatigue life of the tested materials (21,393 +/- 2,356 load cycles), which was significantly greater than that of the other surfaces (P < .001). The compressive surface residual stresses induced when blasting titanium are responsible for this superior mechanical response. Third, precipitation of titanium hydrides in grain boundaries of titanium caused by hydrogen adsorption from the acid solution deteriorates the fatigue life of acid-etched titanium dental implants. These implants had the shortest fatigue life (P < .05). The fatigue life of threaded root-form dental implants varies with the height of the external hexagon and/or the surface treatment of the implant. An external hexagon height of 1.8 mm and/or a blasting treatment appear to significantly increase fatigue life of dental implants.
NASA Astrophysics Data System (ADS)
Rubio, Rafael M.; Salamanca, Juan J.
2018-07-01
The dynamics of external force free motion of pendulums on surfaces of constant Gaussian curvature is addressed when the pivot moves along a geodesic obtaining the Lagrangian of the system. As an application it is possible the study of elastic and quantum pendulums.
External Coulomb-Friction Damping For Hydrostatic Bearings
NASA Technical Reports Server (NTRS)
Buckmann, Paul S.
1992-01-01
External friction device damps vibrations of shaft and hydrostatic ring bearing in which it turns. Does not rely on wear-prone facing surfaces. Hydrostatic bearing ring clamped in radially flexing support by side plates clamped against radial surfaces by spring-loaded bolts. Plates provide friction against radial motions of shaft.
Fontana, Maria Luiza S Simas Netta; de Souza, Cleber Machado; Bernardino, José Fabio; Hoette, Felix; Hoette, Maura Levi; Thum, Lotario; Ozawa, Terumi O; Capelozza Filho, Leopoldino; Olandoski, Marcia; Trevilatto, Paula Cristina
2012-09-01
Vitamin D is responsible for the regulation of certain genes at the transcription level, via interaction with the vitamin D receptor, and influences host immune responses and aspects of bone development, growth, and homeostasis. Our aim was to investigate the association of TaqI vitamin D receptor gene polymorphism with external apical root resorption during orthodontic treatment. Our subjects were 377 patients with Class II Division 1 malocclusion, divided into 3 groups: (1) 160 with external apical root resorption ≤1.43 mm, (2) 179 with external apical root resorption >1.43 mm), and (3) 38 untreated subjects. External apical root resorption of the maxillary incisors was evaluated on periapical radiographs taken before and after 6 months of treatment. After DNA collection and purification, vitamin D receptor TaqI polymorphism analysis was performed by polymerase chain reaction-restriction fragment length polymorphism. Univariate and multivariate analyses were performed to verify the association of clinical and genetic variables with external apical root resorption (P <0.05). There was a higher proportion of external apical root resorption in orthodontically treated patients compared with the untreated subjects. In patients orthodontically treated, age higher than 14 years old, initial size of the maxillary incisor root superior to 30 mm, and premolar extraction were associated with increased external apical root resorption. Genotypes containing the C allele were weakly associated with protection against external apical root resorption (CC + CT × TT [odds ratio, 0.29; 95% confidence interval, 0.07-1.23; P = 0.091]) when treated orthodontic patients were compared to untreated individuals. Clinical factors and vitamin D receptor TaqI polymorphism were associated with external apical root resorption in orthodontic patients. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Kiene, J; Schulz, Arndt P; Hillbricht, S; Jürgens, Ch; Paech, A
2009-01-28
The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations.
Interactions on External MOF Surfaces: Desorption of Water and Ethanol from CuBDC Nanosheets.
Elder, Alexander C; Aleksandrov, Alexandr B; Nair, Sankar; Orlando, Thomas M
2017-10-03
The external surfaces of metal-organic framework (MOF) materials are difficult to experimentally isolate due to the high porosities of these materials. MOF surface surrogates in the form of copper benzenedicarboxylate (CuBDC) nanosheets were synthesized using a bottom-up approach, and the surface interactions of water and ethanol were investigated by temperature-programmed desorption (TPD). A method of analysis of diffusion-influenced TPD was developed to measure the desorption properties of these porous materials. This approach also allows the extraction of diffusion coefficients from TPD data. The transmission Fourier transform infrared spectra, powder X-ray diffraction patterns, and TPD data indicate that water desorbs from CuBDC nanosheets with activation energies of 44 ± 2 kJ/mol at edge sites and 58 ± 1 kJ/mol at external surface and internal and pore sites. Ethanol desorbs with activation energies of 58 ± 1 kJ/mol at internal pore sites and 66 ± 0.4 kJ/mol at external surface sites. Co-adsorption of water and ethanol was also investigated. The presence of ethanol was found to inhibit the desorption of water, resulting in a water desorption process with an activation energy of 68 ± 0.7 kJ/mol.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uri, N.; Gips, S.; Front, A.
1991-06-01
Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 {plus minus} 0.16 in patients with NEO and 1.08 {plus minus} 0.09 in patients with severe external otitis, and formore » gallium 67 scintigraphy they were 1.35 {plus minus} 0.24 in NEO patients and 1.05 {plus minus} 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative scoring method (scores 0 to +4), according to the intensity of the radiopharmaceutical uptake. This method was found to be inferior in the diagnosis of NEO compared with the quantitative method. We conclude that lesion-to-nonlesion ratios greater than 1.5 and 1.3 on bone and gallium 67 scintigraphy, respectively, are indicative of NEO. Quantitative bone scintigraphy, which is quicker to perform, may be used as a single imaging modality for the diagnosis of NEO.« less
Fasoli, Marianna; Dell'Anna, Rossana; Dal Santo, Silvia; Balestrini, Raffaella; Sanson, Andrea; Pezzotti, Mario; Monti, Francesca; Zenoni, Sara
2016-06-01
Grapevine berry skin is a complex structure that contributes to the final size and shape of the fruit and affects its quality traits. The organization of cell wall polysaccharides in situ and their modification during ripening are largely uncharacterized. The polymer structure of Corvina berry skin, its evolution during ripening and related modifying genes were determined by combing mid-infrared micro-spectroscopy and multivariate statistical analysis with transcript profiling and immunohistochemistry. Spectra were acquired in situ using a surface-sensitive technique on internal and external sides of the skin without previous sample pre-treatment, allowing comparison of the related cell wall polymer dynamics. The external surface featured cuticle-related bands; the internal surface showed more adsorbed water. Application of surface-specific normalization revealed the major molecular changes related to hemicelluloses and pectins in the internal surface and to cellulose and pectins in the external surface and that they occur between mid-ripening and full ripening in both sides of the skin. Transcript profiling of cell wall-modifying genes indicated a general suppression of cell wall metabolism during ripening. Genes related to pectin metabolism-a β-galactosidase, a pectin(methyl)esterase and a pectate lyase-and a xyloglucan endotransglucosylase/hydrolase, involved in hemicellulose modification, showed enhanced expression. In agreement with Fourier transform infrared spectroscopy, patterns due to pectin methyl esterification provided new insights into the relationship between pectin modifications and the associated transcript profile during skin ripening. This study proposes an original description of polymer dynamics in grape berries during ripening, highlighting differences between the internal and external sides of the skin. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.
TH-AB-202-11: Spatial and Rotational Quality Assurance of 6DOF Patient Tracking Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belcher, AH; Liu, X; Grelewicz, Z
2016-06-15
Purpose: External tracking systems used for patient positioning and motion monitoring during radiotherapy are now capable of detecting both translations and rotations (6DOF). In this work, we develop a novel technique to evaluate the 6DOF performance of external motion tracking systems. We apply this methodology to an infrared (IR) marker tracking system and two 3D optical surface mapping systems in a common tumor 6DOF workspace. Methods: An in-house designed and built 6DOF parallel kinematics robotic motion phantom was used to follow input trajectories with sub-millimeter and sub-degree accuracy. The 6DOF positions of the robotic system were then tracked and recordedmore » independently by three optical camera systems. A calibration methodology which associates the motion phantom and camera coordinate frames was first employed, followed by a comprehensive 6DOF trajectory evaluation, which spanned a full range of positions and orientations in a 20×20×16 mm and 5×5×5 degree workspace. The intended input motions were compared to the calibrated 6DOF measured points. Results: The technique found the accuracy of the IR marker tracking system to have maximal root mean square error (RMSE) values of 0.25 mm translationally and 0.09 degrees rotationally, in any one axis, comparing intended 6DOF positions to positions measured by the IR camera. The 6DOF RSME discrepancy for the first 3D optical surface tracking unit yielded maximal values of 0.60 mm and 0.11 degrees over the same 6DOF volume. An earlier generation 3D optical surface tracker was observed to have worse tracking capabilities than both the IR camera unit and the newer 3D surface tracking system with maximal RMSE of 0.74 mm and 0.28 degrees within the same 6DOF evaluation space. Conclusion: The proposed technique was effective at evaluating the performance of 6DOF patient tracking systems. All systems examined exhibited tracking capabilities at the sub-millimeter and sub-degree level within a 6DOF workspace.« less
Kondo, Takahiro; Guo, Donghui; Shikano, Taishi; Suzuki, Tetsuya; Sakurai, Masataka; Okada, Susumu; Nakamura, Junji
2015-01-01
Under perpendicular external magnetic fields, two-dimensional carriers exhibit Landau levels (LLs). However, it has recently been reported that LLs have been observed on graphene and graphite surfaces without external magnetic fields being applied. These anomalous LLs have been ascribed primarily to a strain of graphene sheets, leading to in-plane hopping modulation of electrons. Here, we report the observation of the LLs of massive Dirac fermions on atomically flat areas of a nitrogen-doped graphite surface in the absence of external magnetic fields. The corresponding magnetic fields were estimated to be as much as approximately 100 T. The generation of the LLs at the area with negligible strain can be explained by inequivalent hopping of π electrons that takes place at the perimeter of high-potential domains surrounded by positively charged substituted graphitic-nitrogen atoms. PMID:26549618
Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei
2015-01-01
Background To compare risk of carpal tunnel syndrome (CTS) in distal radius fracture (DRF) patients after 7 treatments using bridging external fixation (BrEF), non-bridging external fixation (non-BrEF), plaster fixation, K-wire fixation, dorsal plating fixation, volar plating fixation, and dorsal and volar plating by performing a network meta-analysis. Material/Methods An exhaustive search of electronic databases identified randomized controlled trails (RCTs) closely related to our study topic. The published articles were screened, based on predefined inclusion and exclusion criteria, to select high-quality studies for the present network meta-analysis. Data extracted from the selected studies were analyzed using STATA version 12.0 software. Results The literature search and selection process identified 12 eligible RCTs that contained a total of 1370 DRF patients (394 patients with BrEF, 377 patients with non-BrEF, 89 patients with K-wire fixation, 192 patients with plaster fixation, 42 patients with dorsal plating fixation, 152 patients with volar plating fixation, and 124 patients with dorsal and volar plating fixation). Our network meta-analysis results demonstrated no significant differences in CTS risk among the 7 treatments (P>0.05). The value of surface under the cumulative ranking curve (SUCRA), however, suggested that dorsal plating fixation is the optimal treatment, with the lowest risk of CTS in DRF patients (dorsal plating fixation: 89.2%; dorsal and volar plating: 57.8%; plaster fixation: 50.9%; non-BrEF: 50.6%; volar plating fixation: 39.6%; BrEF: 38.4%; K-wire fixation: 23.6%). Conclusions Our network meta-analysis provides evidence that dorsal plating fixation significantly decreases the risk of CTS and could be the method of choice in DRF patients. PMID:26391617
Bundle of measures for external cerebral ventricular drainage-associated ventriculitis.
Chatzi, Maria; Karvouniaris, Marios; Makris, Demosthenes; Tsimitrea, Eleni; Gatos, Charalampos; Tasiou, Anastasia; Mantzarlis, Kostas; Fountas, Kostas N; Zakynthinos, Epaminondas
2014-01-01
To assess the prevalence and outcome of external cerebral ventricular drainage-associated ventriculitis in neurocritical patients before and after the implementation of a bundle of external cerebral ventricular drainage-associated ventriculitis control measures. Clinical prospective case series. University Hospital of Larissa, Greece. Consecutive patients were recruited from the ICU of the hospital. Patient inclusion criteria included presence of external ventricular drainage and ICU stay more than 48 hours. The bundle of external cerebral ventricular drainage-associated ventriculitis control measures included 1) reeducation of ICU personnel on issues of infection control related to external cerebral ventricular drainage, 2) meticulous intraventricular catheter handling, 3) cerebrospinal fluid sampling only when clinically necessary, and 4) routine replacement of the drainage catheter on the seventh drainage day if the catheter was still necessary. The bundle was applied after an initial period (preintervention) where standard policy for external cerebral ventricular drainage-associated ventriculitis was established. External cerebral ventricular drainage-associated ventriculitis prevalence, external cerebral ventricular drainage-associated ventriculitis events per 1,000 drainage days (drain-associated infection rate), length of ICU stay, Glasgow Outcome Scale at 6 months, and risk factors for external cerebral ventricular drainage-associated ventriculitis. Eighty-two patients entered the study in the preintervention period and 57 patients during the intervention period. During the preintervention and intervention period, external cerebral ventricular drainage-associated ventriculitis prevalence was 28% and 10.5% (p = 0.02) and drain-associated infection rate was 18 and 7.1, respectively (p = 0.0001); mean (95% CI) length of ICU stay in patients who presented external cerebral ventricular drainage-associated ventriculitis was 44.4 days (36.4-52.4 d), whereas mean (95% CI) length of ICU stay in patients who did not was 20 days (16.9-23.2 d) (p < 0.001). Furthermore, the length of ICU stay was associated with length of drainage (p = 0.0001). Therefore, the presence of external cerebral ventricular drainage-associated ventriculitis and the length of drainage were the only variables associated with a prolonged ICU stay. Unfavorable outcome in Glasgow Outcome Scale at 6 months was not associated with the presence of external cerebral ventricular drainage-associated ventriculitis (p = 0.5). No significant differences were found when Glasgow Outcome Scale was analyzed according to the two study periods. The implementation of a bundle of measures for external cerebral ventricular drainage-associated ventriculitis control was associated with significantly decreased postintervention prevalence of the infection.
[The relevance of internal and external participation for patient satisfaction].
Zimmermann, L; Michaelis, M; Quaschning, K; Müller, C; Körner, M
2014-08-01
Patient satisfaction is an essential quality and outcome criteria for patient-centered treatment of chronic diseases. For successful implementation of integrated patient-centered care it is important to take the needs and expectations of the patients into consideration in the treatment process and to involve them in decision-making (external participation), as well as establishing patient-centered collaboration within the team and organization (internal participation). This study examines in what respect patient satisfaction can be predicted through parameters that focus on the personal needs of the individual or internal and external participation. To this end we used a multicenter cross-sectional study to collect evaluations from N=329 patients with different chronic diseases in 11 rehabilitation clinics. Patient satisfaction (ZUF-8) served as the criterion, and the predictors were external participation (PEF-FB-9), satisfaction with decision-making (Man-Son-Hing Scale) and internal participation (Internal Participation Scale), socio-demographic factors and rehabilitation status (IRES-24). The data were analyzed statistically using multiple linear regression. A high degree of variance of patient satisfaction could be explained by the parameters applied (Goodness-of-fit: R²corrected=47.3%). The strongest predictors of satisfaction were internal participation (Beta=0.44, p<0.001) and satisfaction with the decision-making (Beta=0.36, p<0.001). The study provides initial indications of the positive effects of internal and external participation. Further studies are necessary to substantiate the connection between internal and external participation and patient satisfaction. © Georg Thieme Verlag KG Stuttgart · New York.
Intravenous nitroglycerin for external cephalic version: a randomized controlled trial.
Hilton, Jennifer; Allan, Bruce; Swaby, Cheryl; Wahba, Raouf; Wah, Raouf; Jarrell, John; Wood, Stephen; Ross, Sue; Tran, Quynh
2009-09-01
To estimate whether treatment with intravenous nitroglycerin for uterine relaxation increases the chance of successful external cephalic version. Two double-blind, randomized clinical trials were undertaken: one in nulliparous women and a second in multiparous women. Women presenting for external cephalic version at term were eligible to participate. The primary outcome was immediate success of external cephalic version. Other outcomes were presentation at delivery, cesarean delivery rate, and side effects and complications. Sample size calculations were based on a 100% increase in success of external cephalic version with a one-sided analysis and alpha=0.05 (80% power). In total, 126 women were recruited-82 in the nulliparous trial and 44 in the multiparous trial. Seven patients did not have external cephalic version before delivery but were included in the analysis of success of external cephalic version. One patient was lost to follow-up. The external cephalic version success rate for nulliparous patients was 24% (10 of 42) in patients who received nitroglycerin compared with 8% (3 of 40) in those who receive placebo (P=.04, one-sided Fisher exact test, odds ratio 3.85, lower bound 1.22). In multiparous patients, the external cephalic version success rate did not differ significantly between groups: 44% (10 of 23) in the nitroglycerin group compared with 43% (9 of 21) in the placebo group (P=.60). Treatment with intravenous nitroglycerin increased the rate of successful external cephalic version in nulliparous, but not in multiparous, women. Treatment with intravenous nitroglycerin appeared to be safe, but our numbers were too small to rule out rare serious adverse effects. I.
Mitochondrial-dependent Autoimmunity in Membranous Nephropathy of IgG4-related Disease
Buelli, Simona; Perico, Luca; Galbusera, Miriam; Abbate, Mauro; Morigi, Marina; Novelli, Rubina; Gagliardini, Elena; Tentori, Chiara; Rottoli, Daniela; Sabadini, Ettore; Saito, Takao; Kawano, Mitsuhiro; Saeki, Takako; Zoja, Carlamaria; Remuzzi, Giuseppe; Benigni, Ariela
2015-01-01
The pathophysiology of glomerular lesions of membranous nephropathy (MN), including seldom-reported IgG4-related disease, is still elusive. Unlike in idiopathic MN where IgG4 prevails, in this patient IgG3 was predominant in glomerular deposits in the absence of circulating anti-phospholipase A2 receptor antibodies, suggesting a distinct pathologic process. Here we documented that IgG4 retrieved from the serum of our propositus reacted against carbonic anhydrase II (CAII) at the podocyte surface. In patient's biopsy, glomerular CAII staining increased and co-localized with subepithelial IgG4 deposits along the capillary walls. Patient's IgG4 caused a drop in cell pH followed by mitochondrial dysfunction, excessive ROS production and cytoskeletal reorganization in cultured podocytes. These events promoted mitochondrial superoxide-dismutase-2 (SOD2) externalization on the plasma membrane, becoming recognizable by complement-binding IgG3 anti-SOD2. Among patients with IgG4-related disease only sera of those with IgG4 anti-CAII antibodies caused low intracellular pH and mitochondrial alterations underlying SOD2 externalization. Circulating IgG4 anti-CAII can cause podocyte injury through processes of intracellular acidification, mitochondrial oxidative stress and neoantigen induction in patients with IgG4 related disease. The onset of MN in a subset of patients could be due to IgG4 antibodies recognizing CAII with consequent exposure of mitochondrial neoantigen in the context of multifactorial pathogenesis of disease. PMID:26137589
NASA Astrophysics Data System (ADS)
Walicka, A.; Walicki, E.; Jurczak, P.; Falicki, J.
2017-08-01
In the paper, the influence of both the bearing surfaces roughness as well as porosity of one bearing surface on the pressure distribution and load-carrying capacity of a curvilinear, externally pressurized, thrust bearing is discussed. The equations of motion of a pseudo-plastic Rabinowitsch fluid are used to derive the Reynolds equation. After general considerations on the flow in a bearing clearance and in a porous layer using the Morgan-Cameron approximation and Christensen theory of hydrodynamic lubrication with rough bearing surfaces the modified Reynolds equation is obtained. The analytical solution is presented; as a result one obtains the formulae expressing the pressure distribution and load-carrying capacity. Thrust radial and conical bearings, externally pressurized, are considered as numerical examples.
Method for forming synthesis gas using a plasma-catalyzed fuel reformer
Hartvigsen, Joseph J; Elangovan, S; Czernichowski, Piotr; Hollist, Michele
2015-04-28
A method of forming a synthesis gas utilizing a reformer is disclosed. The method utilizes a reformer that includes a plasma zone to receive a pre-heated mixture of reactants and ionize the reactants by applying an electrical potential thereto. A first thermally conductive surface surrounds the plasma zone and is configured to transfer heat from an external heat source into the plasma zone. The reformer further includes a reaction zone to chemically transform the ionized reactants into synthesis gas comprising hydrogen and carbon monoxide. A second thermally conductive surface surrounds the reaction zone and is configured to transfer heat from the external heat source into the reaction zone. The first thermally conductive surface and second thermally conductive surface are both directly exposed to the external heat source. A corresponding apparatus and system are also disclosed herein.
Sánchez, Maria Bernarda Salazar; Valdivieso, Alher Mauricio Hernández; Villanueva, Miguel Ángel Mañanas; Salazar, Andrés Felipe Zuluaga
2017-01-01
This study aimed to explore the usefulness of measuring respiratory muscle activity in mechanically ventilated patients suffering from acute organophosphate poisoning, with a view towards providing complementary information to determine the best time to suspend ventilatory support. Surface electromyography in respiratory muscles (diaphragm, external intercostal and sternocleidomastoid muscles) was recorded in a young man affected by self-poisoning with an unknown amount of parathion to determine the muscle activity level during several weaning attempts from mechanical ventilation. The energy distribution of each surface electromyography signal frequency, the synchronization between machine and patient and between muscles, acetylcholinesterase enzyme activity, and work of breathing and rapid shallow breathing indices were calculated in each weaning attempt. The work of breathing and rapid shallow breathing indices were not correlated with the failure/success of the weaning attempt. The diaphragm gradually increased its engagement with ventilation, achieving a maximal response that correlated with successful weaning and maximal acetylcholinesterase enzyme activity; in contrast, the activity of accessory respiratory muscles showed an opposite trend.
Sánchez, Maria Bernarda Salazar; Valdivieso, Alher Mauricio Hernández; Villanueva, Miguel Ángel Mañanas; Salazar, Andrés Felipe Zuluaga
2017-01-01
This study aimed to explore the usefulness of measuring respiratory muscle activity in mechanically ventilated patients suffering from acute organophosphate poisoning, with a view towards providing complementary information to determine the best time to suspend ventilatory support. Surface electromyography in respiratory muscles (diaphragm, external intercostal and sternocleidomastoid muscles) was recorded in a young man affected by self-poisoning with an unknown amount of parathion to determine the muscle activity level during several weaning attempts from mechanical ventilation. The energy distribution of each surface electromyography signal frequency, the synchronization between machine and patient and between muscles, acetylcholinesterase enzyme activity, and work of breathing and rapid shallow breathing indices were calculated in each weaning attempt. The work of breathing and rapid shallow breathing indices were not correlated with the failure/success of the weaning attempt. The diaphragm gradually increased its engagement with ventilation, achieving a maximal response that correlated with successful weaning and maximal acetylcholinesterase enzyme activity; in contrast, the activity of accessory respiratory muscles showed an opposite trend. PMID:28977266
Gunst, V; Huybrechts, B; De Almeida Neves, A; Bergmans, L; Van Meerbeek, B; Lambrechts, P
2011-03-01
To present two cases of external cervical resorption (ECR) on maxillary incisors, in which the primary aetiologic factor is suggested to be pressure trauma by frequently playing wind instruments. The exact aetiological spectrum of ECR is still poorly understood. For resorption to occur, a defect in the cementum layer (trigger) is a likely prerequisite. Whilst the mechanism for continuation (stimulus) is still unclear, knowledge of potential predisposing factors is important in assessing patients at risk. Pressure generated by playing wind instruments could present an aetiological factor in ECR because it affects the cervical region of the root surface. The cases that are presented may confirm this hypothesis and the extent of resorption defects is shown by cone-beam computer tomography (CT) and micro-focus CT imaging techniques. © 2010 International Endodontic Journal.
Internal phase transition induced by external forces in Finsler geometric model for membranes
NASA Astrophysics Data System (ADS)
Koibuchi, Hiroshi; Shobukhov, Andrey
2016-10-01
In this paper, we numerically study an anisotropic shape transformation of membranes under external forces for two-dimensional triangulated surfaces on the basis of Finsler geometry. The Finsler metric is defined by using a vector field, which is the tangential component of a three-dimensional unit vector σ corresponding to the tilt or some external macromolecules on the surface of disk topology. The sigma model Hamiltonian is assumed for the tangential component of σ with the interaction coefficient λ. For large (small) λ, the surface becomes oblong (collapsed) at relatively small bending rigidity. For the intermediate λ, the surface becomes planar. Conversely, fixing the surface with the boundary of area A or with the two-point boundaries of distance L, we find that the variable σ changes from random to aligned state with increasing of A or L for the intermediate region of λ. This implies that an internal phase transition for σ is triggered not only by the thermal fluctuations, but also by external mechanical forces. We also find that the frame (string) tension shows the expected scaling behavior with respect to A/N (L/N) at the intermediate region of A (L) where the σ configuration changes between the disordered and ordered phases. Moreover, we find that the string tension γ at sufficiently large λ is considerably smaller than that at small λ. This phenomenon resembles the so-called soft-elasticity in the liquid crystal elastomer, which is deformed by small external tensile forces.
Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan
2013-09-01
Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In fractures types B and C dynamic external skeletal fixation allows early mobility in the ankle joint.
DeAngelis, Nicola A; Eskander, Mark S; French, Bruce G
2007-04-01
To identify whether medial tenderness is a predictor of deep deltoid ligament incompetence in supination-external rotation ankle fractures. All Weber B lateral malleolar fractures with normal medial clear space over a 9 month period were prospectively included in the study. Fracture patterns not consistent with a supination-external rotation mechanism were excluded. High-volume tertiary care referral center and Level I trauma center. Fifty-five skeletally mature patients with a Weber B lateral malleolar fracture and normal medial clear space presenting to our institution were included. All study patients had ankle anteroposterior, lateral, and mortise radiographs. Each patient was seen and evaluated by an orthopedic specialist and the mechanism of injury was recorded. Each patient was assessed for tenderness to palpation in the region of the deltoid ligament and then had an external rotation stress mortise radiograph. Correlating medial tenderness with deep deltoid competence as measured by stress radiographs. Thirteen patients (23.6%) were tender medially and had a positive external rotation stress radiograph. Thirteen patients (23.6%) were tender medially and had a negative external rotation stress radiograph. Nineteen patients (34.5%) were nontender medially and had a negative external rotation stress radiograph. Ten patients (18.2%) were nontender medially and had a positive external rotation stress radiograph. We calculated a chi statistic of 2.37 as well as the associated P value of 0.12. Medial tenderness as a measure of deep deltoid ligament incompetence had a sensitivity of 57%, a specificity of 59%, a positive predictive value of 50%, a negative predictive value of 66%, and an accuracy of 42%. There was no statistical significance between the presence of medial tenderness and deep deltoid ligament incompetence. There is a 25% chance of the fracture in question with medial tenderness having a positive external rotation stress and a 25% chance the fracture with no medial tenderness having a positive stress test. Medial tenderness in a Weber B lateral ankle fracture with a normal clear space on standard plain radiographs does not ensure the presence of a positive external rotation stress test.
[Internal and external haemorrhoids].
Schuurman, J P; Go, P M N Y H
2011-01-01
In this article, we present 3 cases of patients with different types of haemorrhoidal disease. The first patient is a 27-year-old woman who had been experiencing incidental rectal blood loss without pain during defecation for 3 months. The second patient is a 76-year-old woman who had been bothered by varying degrees of pain from a swelling nearby the anus for 1 year. The third case involves a 31-year-old man who had had continuous severe pain in the anal area for 3 consecutive days. The first patient appeared to have internal hemorrhoids, whereas different forms of external hemorrhoids affected the patients in the other 2 cases. Internal haemorrhoids develop from the intraluminal corpus cavernosum recti; external haemorrhoids from the perianal marginal veins. Patients with internal haemorrhoids present with symptoms that include blood loss and prolaps feeling during defecation. In patients with external haemorrhoids pain is the prominent symptom. Internal haemorrhoids are treated either conservatively or surgically, depending upon their severity. Considering external haemorrhoidal disease surgical treatment provides the most rapid and persistent relief of symptoms.
An image‐based method to synchronize cone‐beam CT and optical surface tracking
Schaerer, Joël; Riboldi, Marco; Sarrut, David; Baroni, Guido
2015-01-01
The integration of in‐room X‐ray imaging and optical surface tracking has gained increasing importance in the field of image guided radiotherapy (IGRT). An essential step for this integration consists of temporally synchronizing the acquisition of X‐ray projections and surface data. We present an image‐based method for the synchronization of cone‐beam computed tomography (CBCT) and optical surface systems, which does not require the use of additional hardware. The method is based on optically tracking the motion of a component of the CBCT/gantry unit, which rotates during the acquisition of the CBCT scan. A calibration procedure was implemented to relate the position of the rotating component identified by the optical system with the time elapsed since the beginning of the CBCT scan, thus obtaining the temporal correspondence between the acquisition of X‐ray projections and surface data. The accuracy of the proposed synchronization method was evaluated on a motorized moving phantom, performing eight simultaneous acquisitions with an Elekta Synergy CBCT machine and the AlignRT optical device. The median time difference between the sinusoidal peaks of phantom motion signals extracted from the synchronized CBCT and AlignRT systems ranged between ‐3.1 and 12.9 msec, with a maximum interquartile range of 14.4 msec. The method was also applied to clinical data acquired from seven lung cancer patients, demonstrating the potential of the proposed approach in estimating the individual and daily variations in respiratory parameters and motion correlation of internal and external structures. The presented synchronization method can be particularly useful for tumor tracking applications in extracranial radiation treatments, especially in the field of patient‐specific breathing models, based on the correlation between internal tumor motion and external surface surrogates. PACS number: 87
10 CFR 71.47 - External radiation standards for all packages.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 2 2013-01-01 2013-01-01 false External radiation standards for all packages. 71.47... MATERIAL Package Approval Standards § 71.47 External radiation standards for all packages. (a) Except as... the radiation level does not exceed 2 mSv/h (200 mrem/h) at any point on the external surface of the...
10 CFR 71.47 - External radiation standards for all packages.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 2 2014-01-01 2014-01-01 false External radiation standards for all packages. 71.47... MATERIAL Package Approval Standards § 71.47 External radiation standards for all packages. (a) Except as... the radiation level does not exceed 2 mSv/h (200 mrem/h) at any point on the external surface of the...
10 CFR 71.47 - External radiation standards for all packages.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 2 2012-01-01 2012-01-01 false External radiation standards for all packages. 71.47... MATERIAL Package Approval Standards § 71.47 External radiation standards for all packages. (a) Except as... the radiation level does not exceed 2 mSv/h (200 mrem/h) at any point on the external surface of the...
Zhang, Yong; Wang, Zhen-Ning; He, Lei; Gao, Ge; Zhai, Qing; Yin, Zhi-Tao; Zeng, Xian-Dong
2014-01-01
AIM: To evaluate the efficacy of botulinum toxin type A injection to the puborectalis and external sphincter muscle in the treatment of patients with anismus unresponsive to simple biofeedback training. METHODS: This retrospective study included 31 patients suffering from anismus who were unresponsive to simple biofeedback training. Diagnosis was made by anorectal manometry, balloon expulsion test, surface electromyography of the pelvic floor muscle, and defecography. Patients were given botulinum toxin type A (BTX-A) injection and pelvic floor biofeedback training. Follow-up was conducted before the paper was written. Improvement was evaluated using the chronic constipation scoring system. RESULTS: BTX-A injection combined with pelvic floor biofeedback training achieved success in 24 patients, with 23 maintaining persistent satisfaction during a mean period of 8.4 mo. CONCLUSION: BTX-A injection combined with pelvic floor biofeedback training seems to be successful for intractable anismus. PMID:25253964
Zhang, Yong; Wang, Zhen-Ning; He, Lei; Gao, Ge; Zhai, Qing; Yin, Zhi-Tao; Zeng, Xian-Dong
2014-09-21
To evaluate the efficacy of botulinum toxin type A injection to the puborectalis and external sphincter muscle in the treatment of patients with anismus unresponsive to simple biofeedback training. This retrospective study included 31 patients suffering from anismus who were unresponsive to simple biofeedback training. Diagnosis was made by anorectal manometry, balloon expulsion test, surface electromyography of the pelvic floor muscle, and defecography. Patients were given botulinum toxin type A (BTX-A) injection and pelvic floor biofeedback training. Follow-up was conducted before the paper was written. Improvement was evaluated using the chronic constipation scoring system. BTX-A injection combined with pelvic floor biofeedback training achieved success in 24 patients, with 23 maintaining persistent satisfaction during a mean period of 8.4 mo. BTX-A injection combined with pelvic floor biofeedback training seems to be successful for intractable anismus.
International Space Station External Contamination Status
NASA Technical Reports Server (NTRS)
Mikatarian, Ron; Soares, Carlos
2000-01-01
PResentation slides examine external contamination requirements; International Space Station (ISS) external contamination sources; ISS external contamination sensitive surfaces; external contamination control; external contamination control for pre-launch verification; flight experiments and observations; the Space Shuttle Orbiter waste water dump, materials outgassing, active vacuum vents; example of molecular column density profile, modeling and analysis tools; sources of outgassing induced contamination analyzed to date, quiescent sources, observations on optical degradation due to induced external contamination in LEO; examples of typical contaminant and depth profiles; and status of the ISS system, material outgassing, thruster plumes, and optical degradation.
Preparation research of Nano-SiC/Ni-P composite coating under a compound field
NASA Astrophysics Data System (ADS)
Zhou, H. Z.; Wang, W. H.; Gu, Y. Q.; Liu, R.; Zhao, M. L.
2016-07-01
In this paper, the preparation process of Ni-P-SiC composite coatings on 45 steel surfaces with the assistance of magnetic and ultrasound fields was researched. The influence of external field on the surface morphology and performance of the composite layer is also discussed. Experimental results showed that when prepared under magnetic and ultrasonic fields, composite layers are significantly more dense and uniform than coatings made without external fields. Nano-SiC particles, dispersed uniformly in the layer, significantly improve the hardness of the composite layer, and the composite layer under the external field had the highest hardness at 680 HV The external fields can also accelerate deposition and increase the thickness of the layer. Compared to layers processed without the assistance of external fields, the thickness of the layers increased by nearly ten µm.
[External periareolar incision for subdermal mastectomy in men with gynecomastia].
Montiel-Jarquín, Alvaro; Reyes-Páramo, Pedro; Ramos-Alvarez, Gloria; López-Colombo, Aurelio; Tinajero-Esquivel, Magdalena; Ruiz-León, Betzabé
2007-01-01
Gynecomastia describes a benign increase of the mammary gland in men. When medical treatment fails, symptoms and psychological alterations persist. Subdermal mastectomy is the definitive treatment and can be achieved by different incisions, each with potential complications. We undertook this study to present clinical characteristics of 11 patients with gynecomastia and the results obtained with subdermal mastectomy by means of external periareolar incision. A descriptive cohort study in male patients with gynecomastia was carried out in a third-level medical care hospital. Patients were treated with subdermal mastectomy by means of external periareolar incision. There were 11 male patients with an average age of 19 years (range: 11-60 years), 3 patients (27.2%) with bilateral gynecomastia and 8 patients (72.7%) with unilateral gynecomastia. Average time of evolution was 22 months (range: 16-48 months), 9 patients (81.8%) reported pain, 11 patients (100%) reported psychological alterations with cutaneous alteration, 11 patients (100%) had normal secondary sexual characteristics, 1 patient (9%) had supernumerary nipple development, and 11 patients (100%) had well-defined lesions. According to Simon's classification: seven patients (63.6%) were classified as grade 1, three patients (27.2%) as grade 2 and one patient (9.09%) as grade 3. Each patient had a subdermal mastectomy with external periareolar incision, 11 patients (100%) had a histopathological report of gynecomastia; 1 patient (9.09%) displayed keloid healing and none displayed complications inherent to the surgical procedure. Mastectomy by means of external periareolar incision is useful in the treatment of gynecomastia.
Look, Xinqi; Li, Huihua; Ng, Mingwei; Lim, Eric Tien Siang; Pothiawala, Sohil; Tan, Kenneth Boon Kiat; Sewa, Duu Wen; Shahidah, Nur; Pek, Pin Pin; Ong, Marcus Eng Hock
2018-01-01
Targeted temperature management post-cardiac arrest is currently implemented using various methods, broadly categorized as internal and external. This study aimed to evaluate survival-to-hospital discharge and neurological outcomes (Glasgow-Pittsburgh Score) of post-cardiac arrest patients undergoing internal cooling verses external cooling. A randomized controlled trial of post-resuscitation cardiac arrest patients was conducted from October 2008-September 2014. Patients were randomized to either internal or external cooling methods. Historical controls were selected matched by age and gender. Analysis using SPSS version 21.0 presented descriptive statistics and frequencies while univariate logistic regression was done using R 3.1.3. 23 patients were randomized to internal cooling and 22 patients to external cooling and 42 matched controls were selected. No significant difference was seen between internal and external cooling in terms of survival, neurological outcomes and complications. However in the internal cooling arm, there was lower risk of developing overcooling (p=0.01) and rebound hyperthermia (p=0.02). Compared to normothermia, internal cooling had higher survival (OR=3.36, 95% CI=(1.130, 10.412), and lower risk of developing cardiac arrhythmias (OR=0.18, 95% CI=(0.04, 0.63)). Subgroup analysis showed those with cardiac cause of arrest (OR=4.29, 95% CI=(1.26, 15.80)) and sustained ROSC (OR=5.50, 95% CI=(1.64, 20.39)) had better survival with internal cooling compared to normothermia. Cooling curves showed tighter temperature control for internal compared to external cooling. Internal cooling showed tighter temperature control compared to external cooling. Internal cooling can potentially provide better survival-to-hospital discharge outcomes and reduce cardiac arrhythmia complications in carefully selected patients as compared to normothermia. Copyright © 2017. Published by Elsevier Inc.
Management of Late Onset Perthes: Evaluation of Distraction by External Fixator—5-Year Follow-Up
Srivastava, Rajeshwar N.; Shukla, Prashant; Pushkar, Amit; Ali, Sabir
2014-01-01
Background. Hip distraction in Perthes' disease unloads the joint, which negates the harmful effect of the stresses on the articular surfaces, which may promote the sound healing of the area of necrosis. We have examined the effect of arthrodiastasis on the preservation of the femoral head in older children with Perthes' disease. Methods and Materials. Twelve children with age more than 8 years with Perthes' disease of less than one year were treated with hip distraction by a hinged monolateral external fixator. Observation and Results. Mean duration of distraction was 13.9 days. These children were evaluated by clinicoradiological parameters for a mean period of 32.4 months. There was a significant improvement in the range of movements and mean epiphyseal index, but the change in the percentage of uncovered head femur was insignificant. There was significant improvement in Harris Hip score. Conclusions. Hip distraction by hinged monolateral external fixator seems to be a valid treatment option in cases with Perthes' disease in the selected group of patients, where poor results are expected from conventional treatment. PMID:25580302
NASA Astrophysics Data System (ADS)
Liang, Hui; Chen, Xiaobo
2017-10-01
A novel multi-domain method based on an analytical control surface is proposed by combining the use of free-surface Green function and Rankine source function. A cylindrical control surface is introduced to subdivide the fluid domain into external and internal domains. Unlike the traditional domain decomposition strategy or multi-block method, the control surface here is not panelized, on which the velocity potential and normal velocity components are analytically expressed as a series of base functions composed of Laguerre function in vertical coordinate and Fourier series in the circumference. Free-surface Green function is applied in the external domain, and the boundary integral equation is constructed on the control surface in the sense of Galerkin collocation via integrating test functions orthogonal to base functions over the control surface. The external solution gives rise to the so-called Dirichlet-to-Neumann [DN2] and Neumann-to-Dirichlet [ND2] relations on the control surface. Irregular frequencies, which are only dependent on the radius of the control surface, are present in the external solution, and they are removed by extending the boundary integral equation to the interior free surface (circular disc) on which the null normal derivative of potential is imposed, and the dipole distribution is expressed as Fourier-Bessel expansion on the disc. In the internal domain, where the Rankine source function is adopted, new boundary integral equations are formulated. The point collocation is imposed over the body surface and free surface, while the collocation of the Galerkin type is applied on the control surface. The present method is valid in the computation of both linear and second-order mean drift wave loads. Furthermore, the second-order mean drift force based on the middle-field formulation can be calculated analytically by using the coefficients of the Fourier-Laguerre expansion.
Yeoh, David; Goddard, Richard; Macnamara, Paul; Bowman, Nicholas; Miles, Kim; East, Debra; Butler-Manuel, Adrian
2008-08-01
The most common indication for knee arthrodesis is pain and instability in an unreconstructable knee following an infected knee arthroplasty. In this study, we compare the use of the Mayday arthrodesis nail (Orthodynamics, Christchurch, UK) versus external fixation, Orthofix (Berkshire UK) and Stryker Hoffman II (County Cork, Ireland). All patients in this study underwent arthrodesis between 1995 and 2006 at Conquest Hospital, Hastings. In group A, 11 patients underwent arthrodesis with a Mayday nail. In all cases, the indications were infected total knee replacements (TKR). Three of these patients previously had failed attempts at arthrodesis with external fixation devices. In group B, seven patients underwent arthrodesis using external fixation. In six patients, the indication was infected TKRs. Results were reviewed retrospectively, with union assessed both clinically and radiologically. The mean inpatient stay for the Mayday nail group was 23 days (range 8-45 days) compared with 76 days (range 34-122) for the external fixation group (p<0.01, CI 95). Ten patients in group A went on to confirmed primary arthrodesis. One patient underwent revision arthrodesis with a Mayday nail and subsequently united. In group B only two patients achieved union. The rate of union was significantly greater in the Mayday nail group than the external fixation group (91% vs 29%, p<0.01). Of those patients that achieved union, there was no difference in the time to fusion between groups. Our study supported the existing literature and found that the Mayday nail appeared more effective than monoaxial external fixators for arthrodesis in the management of infected total knee replacements.
Manet, Romain; Payen, Jean-François; Guerin, Romain; Martinez, Orianne; Hautefeuille, Serge; Francony, Gilles; Gergelé, Laurent
2017-10-01
Despite various treatments to control intracranial pressure (ICP) after brain injury, patients may present a late onset of high ICP or a poor response to medications. External lumbar drainage (ELD) can be considered a therapeutic option if high ICP is due to communicating external hydrocephalus. We aimed at describing the efficacy and safety of ELD used in a cohort of traumatic or non-traumatic brain-injured patients. In this multicentre retrospective analysis, patients had a delayed onset of high ICP after the initial injury and/or a poor response to ICP treatments. ELD was considered in the presence of radiological signs of communicating external hydrocephalus. Changes in ICP values and side effects following the ELD procedure were reported. Thirty-three patients with a median age of 51 years (25-75th percentile: 34-61 years) were admitted after traumatic (n = 22) or non-traumatic (n = 11) brain injuries. Their initial Glasgow Coma Scale score was 8 (4-11). Eight patients underwent external ventricular drainage prior to ELD. Median time to ELD insertion was 5 days (4-8) after brain insult. In all patients, ELD was dramatically effective in lowering ICP: 25 mmHg (20-31) before versus 7 mmHg (3-10) after (p < 0.001). None of the patients showed adverse effects such as pupil changes or intracranial bleeding after the procedure. One patient developed an ELD-related infection. These findings indicate that ELD may be considered potentially effective in controlling ICP, remaining safe if a firm diagnosis of communicating external hydrocephalus has been made.
NASA Technical Reports Server (NTRS)
Cubbage, James M.; Monta, William J.
1991-01-01
A parametric experimental investigation of a scramjet nozzle was conducted with a gas mixture used to simulate the scramjet engine exhaust flow at a free-stream Reynolds number of approximately 6.5 x 10(exp 6) per foot. External nozzle surface angles of 16, 20, and 24 deg were tested with a fixed-length ramp and for cowl internal surface angles of 6 and 12 deg. Pressure data on the external nozzle surface were obtained for mixtures of Freon and argon gases with a ratio of specific heats of about 1.23, which matches that of a scramjet exhaust. Forces and moments were determined by integration of the pressure data. Two nozzle configurations were also tested with air used to simulate the exhaust flow. On the external nozzle surface, lift and thrust forces for air exhaust simulation were approximately half of those for Freon-argon exhaust simulation and the pitching moment was approximately a third. These differences were primarily due to the difference in the ratios of specific heats between the two exhaust simulation gases. A 20 deg external surface angle produced the greatest thrust for a 6 deg cowl internal surface angle. A flow fence significantly increased lift and thrust forces over those for the nozzle without a flow fence.
Time-dynamics of the two-color emission from vertical-external-cavity surface-emitting lasers
NASA Astrophysics Data System (ADS)
Chernikov, A.; Wichmann, M.; Shakfa, M. K.; Scheller, M.; Moloney, J. V.; Koch, S. W.; Koch, M.
2012-01-01
The temporal stability of a two-color vertical-external-cavity surface-emitting laser is studied using single-shot streak-camera measurements. The collected data is evaluated via quantitative statistical analysis schemes. Dynamically stable and unstable regions for the two-color operation are identified and the dependence on the pump conditions is analyzed.
Separation of the Magnetic Field into Parts Produced by Internal and External Sources
NASA Astrophysics Data System (ADS)
Lazanja, David
2005-10-01
Given the total magnetic field on a toroidal plasma surface, a method for decomposing the field into a part due to internal currents (often the plasma) and a part due to external currents is presented. The decomposition exploits Laplace theory which is valid in the vacuum region between the plasma surface and the chamber walls. The method does not assume toroidal symmetry, and it is partly based on Merkel's 1986 work on vacuum field computations. A change in the plasma shape is produced by the total normal field perturbation on the plasma surface. This method allows a separation of the total normal field perturbation into a part produced by external currents and a part produced by the plasma response.
Marker-less respiratory motion modeling using the Microsoft Kinect for Windows
NASA Astrophysics Data System (ADS)
Tahavori, F.; Alnowami, M.; Wells, K.
2014-03-01
Patient respiratory motion is a major problem during external beam radiotherapy of the thoracic and abdominal regions due to the associated organ and target motion. In addition, such motion introduces uncertainty in both radiotherapy planning and delivery and may potentially vary between the planning and delivery sessions. The aim of this work is to examine subject-specific external respiratory motion and its associated drift from an assumed average cycle which is the basis for many respiratory motion compensated applications including radiotherapy treatment planning and delivery. External respiratory motion data were acquired from a group of 20 volunteers using a marker-less 3D depth camera, Kinect for Windows. The anterior surface encompassing thoracic and abdominal regions were subject to principal component analysis (PCA) to investigate dominant variations. The first principal component typically describes more than 70% of the motion data variance in the thoracic and abdominal surfaces. Across all of the subjects used in this study, 58% of subjects demonstrate largely abdominal breathing and 33% exhibited largely thoracic dominated breathing. In most cases there is observable drift in respiratory motion during the 300s capture period, which is visually demonstrated using Kernel Density Estimation. This study demonstrates that for this cohort of apparently healthy volunteers, there is significant respiratory motion drift in most cases, in terms of amplitude and relative displacement between the thoracic and abdominal respiratory components. This has implications for the development of effective motion compensation methodology.
21 CFR 868.5935 - External negative pressure ventilator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ventilator. (a) Identification. An external negative pressure ventilator (e.g., iron lung, cuirass) is a device chamber that is intended to support a patient's ventilation by alternately applying and releasing external negative pressure over the diaphragm and upper trunk of the patient. (b) Classification. Class II...
Engmann, Judith; Rüdrich, Urda; Behrens, Georg; Papakonstantinou, Eleni; Gehring, Manuela; Kapp, Alexander; Raap, Ulrike
2017-04-06
Bullous pemphigoid (BP) is an autoimmune blistering skin disease that is more common in elderly individuals. The aim of this study was to determine the functional activity of eosinophils in patients with BP compared with healthy donors. Blood, skin and blister-derived eosinophils were strongly activated in patients with BP, seen by increased surface expression of CD69 compared with controls. CD11b was also increased in BP blood eosinophils, which may explain the striking accumulation of eosinophils in BP (1×106 per ml blister fluid). Furthermore, CCL26 was expressed by activated eosinophils in BP skin and in blister fluid. BP eosinophils also released IL-6, IL-8 and IL-1α in BP blister fluids. Apoptosis in cultivated BP eosinophils was increased and accompanied by enhanced surface externalization of CD95. Caspase 3 positive eosinophils in lesional BP skin and blister fluid also showed the initiation of apoptosis. These results reveal novel pathophysiological aspects of BP, with a strong activation pattern and increased apoptosis of eosinophils in the peripheral blood, skin and blister fluids.
Hilton, Thomas J; Funkhouser, Ellen; Ferracane, Jack L; Gilbert, Gregg H; Baltuck, Camille; Benjamin, Paul; Louis, David; Mungia, Rahma; Meyerowitz, Cyril
2017-04-01
Cracked teeth are ubiquitous in the adult dentition. The objective of this study was to determine which patient traits and behaviors and external tooth and crack characteristics correlate with cracked teeth being symptomatic. Dentists in The National Dental Practice-Based Research Network enrolled a convenience sample of patients each with a single, vital posterior tooth with at least 1 observable external crack in this observational study; they enrolled 2,975 cracked teeth from 209 practitioners. The authors collected data at the patient level, tooth level, and crack level. They used generalized estimating equations to obtain significant (P < .05) independent odds ratios (OR) associated with teeth that were symptomatic for a crack. Characteristics positively associated with cracked tooth symptoms, after adjusting for demographics, included patients who clenched, ground, or pressed their teeth together (OR, 1.30; 95% confidence interval [CI], 1.12-1.50), molars (OR, 1.58; 95% CI, 1.30-1.92), teeth with a wear facet through enamel (OR, 1.22; 95% CI, 1.01-1.40), carious lesions (OR, 1.31; 95% CI, 1.07-1.60), cracks that were on the distal surface of the tooth (OR, 1.31; 95% CI, 1.13-1.52), and cracks that blocked transilluminated light (OR, 1.31, 95% CI, 1.09-1.57). Teeth with stained cracks were negatively associated with having cracked tooth symptoms (OR, 0.68; 95% CI, 0.55-0.84). The greatest likelihood of a cracked tooth being symptomatic was found when patients reported clenching or grinding their teeth and had a molar with a distal crack that blocked transilluminated light. This information can help inform dentists in the decision-making process regarding the prognosis for a cracked tooth. Copyright © 2017 American Dental Association. Published by Elsevier Inc. All rights reserved.
Simulating CC and MLO compressions with the Surface Evolver
NASA Astrophysics Data System (ADS)
Zanchetta do Nascimento, Marcelo; Ramos Batista, Valério
2015-01-01
Mammographies are X-ray images of the breast under external compressions called Craniocaudal (CC) and Mediolateral Oblique (MLO). Together they increase the chances of detecting cancer but the breast is shown in strongly deformed shapes. Cancer location is highly uncertain for the surgery and so the breast is commonly taken out entirely, a serious trauma for the patient. In this paper we present a fully virtual mammography procedure that faithfully reproduces all shapes of the breast and in its inside tracks the cancer at any step. The cancer is then precisely located for the surgery and can be removed through a small incision. So the whole structure is preserved and cured as an integral benefit to the patient.
Current concepts of ocular adnexal surgery
Borrelli, Maria; Geerling, Gerd
2013-01-01
Ophthalmic Plastic and Reconstructive Surgery is a specialized area of ophthalmology that deals with the management of deformities and abnormalities of the eyelids, lacrimal system and the orbit. An ophthalmoplastic surgeon is able to identify and correct abnormalities of the ocular adnexae such as ectropion, lid retraction, conjunctival scarring with severe entropion, that can cause secondary ocular surface disorders; manage patients with watering eye, and when needed intervene with a dacryocystorhinostomy by external or endonasal approach and moreover minimize disfigurement following enucleation or evisceration and prevent further corneal damage, alleviate complains of tearing and grittiness, but also cosmetic complaints in patients with Graves’ orbitopathy. Aim of this manuscript was to review current established and recently evolving surgical procedures. PMID:26504698
External fixation for displaced intra-articular fractures of the calcaneum.
Magnan, B; Bortolazzi, R; Marangon, A; Marino, M; Dall'Oca, C; Bartolozzi, P
2006-11-01
A minimally-invasive procedure using percutaneous reduction and external fixation can be carried out for Sanders' type II, III and IV fractures of the os calcis. We have treated 54 consecutive closed displaced fractures of the calcaneum involving the articular surface in 52 patients with the Orthofix Calcaneal Mini-Fixator. Patients were followed up for a mean of 49 months (27 to 94) and assessed clinically with the Maryland Foot Score and radiologically with radiographs and CT scans, evaluated according to the Score Analysis of Verona. The clinical results at follow-up were excellent or good in 49 cases (90.7%), fair in two (3.7%) and poor in three (5.6%). The mean pre-operative Böhler's angle was 6.98 degrees (5.95 degrees to 19.86 degrees), whereas after surgery the mean value was 21.94 degrees (12.58 degrees to 31.30 degrees) (p < 0.01). Excellent results on CT scanning were demonstrated in 24 cases (44.4%), good in 25 (46.3%), fair in three (5.6%) and poor in two (3.7%). Transient local osteoporosis was observed in ten patients (18.5%), superficial pin track infection in three (5.6%), and three patients (5.6%) showed thalamic displacement following unadvised early weight-bearing. The clinical results appear to be comparable with those obtainable with open reduction and internal fixation, with the advantages of reduced risk using a minimally-invasive technique.
DeCruze, B; Guthrie, D
1999-01-01
Poor prognosis (poorly differentiated and/or deep myometrial invasion) Stage I endometrial cancer can have a relapse rate as high as 50%. Traditionally, most clinical oncologists treat these patients with external beam radiotherapy after surgery but there is no evidence to show that this improves survival. The retrospective study looks at the results of not giving external beam radiotherapy in 25 consecutive patients and compares the results with a group of 13 consecutive patients who did have such treatment. The two groups were comparable with regard to age, degree of differentiation and degree of invasion. Survival was comparable in the two groups. There is no evidence of any obvious decrease in survival from withholding external beam radiotherapy, but this was not a prospective randomized controlled trial. This study illustrates that it is essential that the Medical Research Council ASTEC trial should be supported because this will determine the true place of external beam radiotherapy in such patients.
Gorbacheva, E V; Ganchenko, G S; Demekhin, E A
2018-03-27
The stability of the electroosmotic flow of electrolyte-dielectric viscous liquids under the influence of the DC and AC electric fields along with the external pressure gradient is studied theoretically. Liquids are bounded by two infinite parallel plates. The lower wall bordering the electrolyte is assumed to be a charged surface, and the upper wall is electrically isolated. The charge at the lower boundary is assumed to be immobile, while the surface charge at the free surface is assumed to be mobile. In this paper, we study the micro- and nanosized liquid layers. The mathematical model is described by a nonlinear system of the Nernst-Planck-Poisson-Stokes partial differential equations with the appropriate boundary conditions on the solid surface, the electrolyte/dielectric interface, and on the upper wall. The pressure gradient is highly important for the stability of the flow. For the DC case, the external pressure could either stabilize and destabilize the flow depending on the relative directions of the electroosmotic flow and the pressure-driven flow. For the AC case, the dependence on the value of the external pressure is not monotonous for different wave numbers of perturbations, but, as a rule, the external pressure destabilizes the flow. As the frequency of the electric field increases, the one-dimensional solution of the problem becomes stable.
Does external evaluation of laboratories improve patient safety?
Noble, Michael A
2007-01-01
Laboratory accreditation and External Quality Assessment (also called proficiency testing) are mainstays of laboratory quality assessment and performance. Both practices are associated with examples of improved laboratory performance. The relationship between laboratory performance and improved patient safety is more difficult to assess because of the many variables that are involved with patient outcome. Despite this difficulty, the argument to continue external evaluation of laboratories is too compelling to consider the alternative.
Capelli, Matteo; Testori, Tiziano; Galli, Fabio; Zuffetti, Francesco; Motroni, Alessandro; Weinstein, Roberto; Del Fabbro, Massimo
2013-12-01
The aim of this study is to investigate contour changes around immediate implants in fresh extraction sockets when different grafting procedures are performed, based on the distance between the external implant collar and the bony surface on the buccal plate (I-BP). A secondary aim is to assess the esthetic outcome via the implant esthetic score (IAS). This prospective cohort study was performed in three centers. Suitable patients to undergo implant placement in fresh extraction sockets were selected. Periodontal biotype, horizontal and vertical peri-implant bone defects, and dehiscences were assessed. Depending on I-BP, two types of grafting procedures were performed. In group A (I-BP <4 mm), only the peri-implant gap was grafted during the surgical phase (internal grafting [IG]), whereas group B (I-BP ≥ 4 mm) received both internal and external grafting (IEG). Master casts of the sites, made before implant placement and after 1 year of loading, were optically scanned. A computerized analysis of the contour changes at the involved sites was performed by superimposing the scanned models. A total of 20 patients (eight males and 12 females) were recruited, and 20 non-submerged implants were placed in fresh extraction sockets. No implant failed during the observation period. The mean follow-up was 25 months (range: 12 to 37 months). After 1 year of loading, group A showed a slight decrease in mean buccal volume, whereas group B had an increase in volume (P = 0.02). IAS was higher for group B than group A. When implants are placed immediately after tooth extraction, I-BP may represent a useful diagnostic parameter in choosing the most appropriate grafting procedure (IG versus IEG). In clinical cases in which the distance between implant surface and the buccal plate is <4 mm, the combination of internal and external grafting (IEG) is recommended to maintain the volume and the contour of the ridge and achieve a successful esthetic outcome.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Xue, E-mail: zhangxue.iecas@yahoo.com; Wang, Yong; Fan, Junjie
2015-02-15
To suppress the surface multipactor phenomenon and improve the transmitting power of the high-power microwave window, the application of external magnetic fields is theoretically analyzed and simulated. A Monte Carlo algorithm is used to track the secondary electron trajectories and study the multipactor scenario on the surface of a cylinder window. It is confirmed that over-resonant magnetic fields (an external magnetic field whose magnitude is slightly greater than that of a resonant magnetic field) will generate a compensating trajectory and collision, which can suppress the secondary electron avalanche. The optimal value of this external magnetic field that will avoid themore » multipactor phenomenon on cylinder windows is discussed.« less
Union rate of tibiotalocalcaneal nails with internal or external bone stimulation.
De Vries, J George; Berlet, Gregory C; Hyer, Christopher F
2012-11-01
The use of bone growth stimulation has been reported in the application of hindfoot and ankle arthrodesis. Most studies have been retrospective case series with few patients. The authors present a comparative analysis of patients undergoing tibiotalocalcaneal (TTC) arthrodesis via a retrograde intramedullary arthrodesis nail to evaluate the influence of internal versus external bone stimulation in this population. One hundred fifty-four patients were treated with retrograde intramedullary nailing. A comprehensive chart and radiographic review was performed from a database of patients who underwent TTC fusion with or without bone stimulation. Ninety-one patients with retrograde TTC nailing were treated with direct current internal bone stimulation at the time of the index procedure (internal group) and 63 were treated with combined magnetic field external bone stimulation (external group). The primary end point was fusion with potential variables evaluated for influence on fusion rates. Demographically the cohorts were similar groups in age and comorbidities. Surgical and outcome data were examined, and there were few statistically significant differences between the two groups. There was no statistically significant difference in rate of union (52.7% and 57.1%, p = .63) or rate of complications between the internal and external groups. Overall, the success rate for achieving a stable, functional limb for the groups was 81.3% (74/91 patients) and 82.5% (52/63 patients) in the internal and external groups, respectively (p = .62). The authors demonstrated there were no statistically significant differences between the union and complication rate when comparing these types of internal and external bone stimulation in this patient population. Consideration of these results may help guide physicians when considering bone stimulation as an adjunct to TTC fusions with a retrograde intramedullary nail.
NASA Astrophysics Data System (ADS)
Ma, X.; Cianciosa, M.; Hanson, J. D.; Hartwell, G. J.; Knowlton, S. F.; Maurer, D. A.; Ennis, D. A.; Herfindal, J. L.
2015-11-01
Non-axisymmetric free-boundary equilibrium reconstructions of stellarator plasmas are performed for discharges in which the magnetic configuration is strongly modified by the driven plasma current. Studies were performed on the Compact Toroidal Hybrid device using the V3FIT reconstruction code incorporating a set of 50 magnetic diagnostics external to the plasma, combined with information from soft X-ray (SXR) arrays. With the assumption of closed magnetic flux surfaces, the reconstructions using external magnetic measurements allow accurate estimates of the net toroidal flux within the last closed flux surface, the edge safety factor, and the outer boundary of these highly non-axisymmetric plasmas. The inversion radius for sawtoothing plasmas is used to identify the location of the q = 1 surface, and thus infer the current profile near the magnetic axis. With external magnetic diagnostics alone, we find the reconstruction to be insufficiently constrained. This work is supported by US Department of Energy Grant No. DE-FG02-00ER54610.
Ionization of Rydberg atoms colliding with a metal surface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sjakste, J.; Borisov, A. G.; Gauyacq, J. P.
2006-04-15
We report on a theoretical study of the ionization process of Xe* Rydberg atoms colliding with a metal surface, in the presence of an external electric field. The evolution of the Xe* outer electron is studied by a wave packet propagation approach, allowing to include all dynamical aspects of the collision, in particular nonadiabatic inter-Rydberg transitions. We investigate how the different Xe* Stark states formed in the external field couple together and ionize on the surface and how the different polarizations of the electronic cloud in the Xe* states are reflected in their ionization properties. We show that the presencemore » of the external electric field can significantly perturb the dynamics of the ionization process. Our results account for recent results from Dunning et al. [Nucl. Inst. Meth. B 203, 69 (2003)]. In particular, it is explained how the external electric field present in the experimental procedure of Dunning et al. leads to the apparent absence of a polarization effect in the ionization process.« less
Klein, A A; Collier, T; Yeates, J; Miles, L F; Fletcher, S N; Evans, C; Richards, T
2017-09-01
A simple and accurate scoring system to predict risk of transfusion for patients undergoing cardiac surgery is lacking. We identified independent risk factors associated with transfusion by performing univariate analysis, followed by logistic regression. We then simplified the score to an integer-based system and tested it using the area under the receiver operator characteristic (AUC) statistic with a Hosmer-Lemeshow goodness-of-fit test. Finally, the scoring system was applied to the external validation dataset and the same statistical methods applied to test the accuracy of the ACTA-PORT score. Several factors were independently associated with risk of transfusion, including age, sex, body surface area, logistic EuroSCORE, preoperative haemoglobin and creatinine, and type of surgery. In our primary dataset, the score accurately predicted risk of perioperative transfusion in cardiac surgery patients with an AUC of 0.76. The external validation confirmed accuracy of the scoring method with an AUC of 0.84 and good agreement across all scores, with a minor tendency to under-estimate transfusion risk in very high-risk patients. The ACTA-PORT score is a reliable, validated tool for predicting risk of transfusion for patients undergoing cardiac surgery. This and other scores can be used in research studies for risk adjustment when assessing outcomes, and might also be incorporated into a Patient Blood Management programme. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Prevention of Thumb Web Space Contracture With Multiplanar External Fixation.
Harper, Carl M; Iorio, Matthew L
2016-09-01
Thumb web space contracture following hand trauma can be disabling with numerous reconstructive procedures existing to correct the resultant deformity. Following marked soft tissue injury to the hand we utilized the Stryker Hoffmann II Micro External Fixator System to link the first and second metacarpals by a multiplanar system using 1.6 or 2.0 mm self-drilling half-pins and 3 mm carbon fiber connecting rods. This facilitated placement of the thumb in maximal palmar abduction as well as allowed adjustment of thumb position throughout the postoperative period. This technique was performed on 5 patients. Two patients were treated with a first web space external fixator for table saw injuries to the radial aspect of the hand. An additional 2 patients were treated with a first web space external fixator following metacarpophalangeal joint capsular release in the setting of thermal burns. A fifth patient underwent second ray amputation, trapeziectomy and trapezoidectomy for squamous cell carcinoma with subsequent stabilization with the external fixator. The external fixator was left in place until soft tissues were healed (average 5.5 wk). The patients were allowed to mobilize their hand in as much as the external fixator allowed, and no device-associated complications were noted. Thumb web space was preserved with passive and supple thumb circumduction and web space abduction/adduction in all patients at an average follow-up of 5 months. The average Quick Dash Score was 35±5 and the average Modern Activity Subjective Survey of 2007 was 30±8.
Self-cleaning of superhydrophobic surfaces by spontaneously jumping condensate drops
NASA Astrophysics Data System (ADS)
Wisdom, Katrina; Watson, Jolanta; Watson, Gregory; Chen, Chuan-Hua
2012-11-01
The self-cleaning function of superhydrophobic surfaces is conventionally attributed to the removal of contaminating particles by impacting or rolling water droplets, which implies the action of external forces such as gravity. Here, we demonstrate a new self-cleaning mechanism, whereby condensate drops spontaneously jump upon coalescence on a superhydrophobic surface, and the merged drop self-propels away from the surface along with the contaminants. The jumping-condensate mechanism is shown to autonomously clean superhydrophobic cicada wings, where the contaminating particles cannot be removed by external wind flow. Our findings offer new insights for the development of self-cleaning materials.
Che, Fanglin; Zhang, Renqin; Hensley, Alyssa J; Ha, Su; McEwen, Jean-Sabin
2014-02-14
To provide a basis for understanding the reactive processes on nickel surfaces at fuel cell anodes, we investigate the influence of an external electric field on the dehydrogenation of methyl species on a Ni(111) surface using density functional theory calculations. The structures, adsorption energies and reaction barriers for all methyl species dissociation on the Ni(111) surface are identified. Our results show that the presence of an external electric field does not affect the structures and favorable adsorption sites of the adsorbed species, but causes the adsorption energies of the CHx species at the stable site to fluctuate around 0.2 eV. Calculations give an energy barrier of 0.692 eV for CH3* → CH2* + H*, 0.323 eV for CH2* → CH* + H* and 1.373 eV for CH* → C* + H*. Finally, we conclude that the presence of a large positive electric field significantly increases the energy barrier of the CH* → C* + H* reaction more than the other two reactions, suggesting that the presence of pure C atoms on Ni(111) are impeded in the presence of an external positive electric field.
Palo, R M; Bonetti-Filho, I; Valera, M C; Camargo, C H R; Camargo, Sea; Moura-Netto, C; Pameijer, C
2012-01-01
The aim of this study was to evaluate the amount of peroxide passage from the pulp chamber to the external enamel surface during the internal bleaching technique. Fifty bovine teeth were sectioned transversally 5 mm below the cemento-enamel junction (CEJ), and the remaining part of the root was sealed with a 2-mm layer of glass ionomer cement. The external surface of the samples was coated with nail varnish, with the exception of standardized circular areas (6-mm diameter) located on the enamel, exposed dentin, or cementum surface of the tooth. The teeth were divided into three experimental groups according to exposed areas close to the CEJ and into two control groups (n=10/group), as follows: GE, enamel exposure area; GC, cementum exposed area; GD, dentin exposed area; Negative control, no presence of internal bleaching agent and uncoated surface; and Positive control, pulp chamber filled with bleaching agent and external surface totally coated with nail varnish. The pulp chamber was filled with 35% hydrogen peroxide (Opalescence Endo, Ultradent). Each sample was placed inside of individual flasks with 1000 μL of acetate buffer solution, 2 M (pH 4.5). After seven days, the buffer solution was transferred to a glass tube, in which 100 μL of leuco-crystal violet and 50 μL of horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to Kruskal-Wallis and Dunn-Bonferroni tests (α=0.05). All experimental groups presented passage of peroxide to the external surface that was statistically different from that observed in the control groups. It was verified that the passage of peroxide was higher in GD than in GE (p<0.01). The GC group presented a significantly lower peroxide passage than did GD and GE (p<0.01). It can be concluded that the hydrogen peroxide placed into the pulp chamber passed through the dental hard tissues, reaching the external surface and the periodontal tissue. The cementum surface was less permeable than were the dentin and enamel surfaces.
MLAA-based RF surface coil attenuation estimation in hybrid PET/MR imaging
NASA Astrophysics Data System (ADS)
Heußer, Thorsten; Rank, Christopher M.; Freitag, Martin T.; Kachelrieß, Marc
2017-03-01
Attenuation correction (AC) for both patient and hardware attenuation of the 511 keV annihilation photons is required for accurate PET quantification. In hybrid PET/MR imaging, AC for stationary hardware components such as patient table and MR head coil is performed using CT{derived attenuation templates. AC for flexible hardware components such as MR radiofrequency (RF) surface coils is more challenging. Registration{based approaches, aligning scaled CT{derived attenuation templates with the current patient position, have been proposed but are not used in clinical routine. Ignoring RF coil attenuation has been shown to result in regional activity underestimation values of up to 18 %. We propose to employ a modified version of the maximum{ likelihood reconstruction of attenuation and activity (MLAA) algorithm to obtain an estimate of the RF coil attenuation. Starting with an initial attenuation map not including the RF coil, the attenuation update of MLAA is applied outside the body outline only, allowing to estimate RF coil attenuation without changing the patient attenuation map. Hence, the proposed method is referred to as external MLAA (xMLAA). In this work, xMLAA for RF surface coil attenuation estimation is investigated using phantom and patient data acquired with a Siemens Biograph mMR. For the phantom data, average activity errors compared to the ground truth was reduced from -8:1% to +0:8% when using the proposed method. Patient data revealed an average activity underestimation of -6:1% for the abdominal region and -5:3% for the thoracic region when ignoring RF coil attenuation.
Treatment of war injuries of the shoulder with external fixators.
Davila, Slavko; Mikulić, Danko; Davila, Neda Jarza; Popović, Ljiljana; Zupancić, Bozidar
2005-05-01
In this retrospective study, 18 patients with war injuries of the shoulder were reviewed to evaluate the technical problems associated with external fixation and to analyze the incidence of infection and late functional results. The average patient age was 28.5 years. All patients were male. Thirteen patients had explosive wounds, whereas five wounds were caused by gunshot missiles. All injuries were extensive in terms of bone and soft tissue defects. Six patients presented with complex injuries involving neurovascular structures. Sixteen patients were treated with external fixation. Application of the proximal pins of the external fixator through the humeral head was possible in eight patients, the scapula served as the site of proximal fixation in four patients, only the clavicle was available for placement of pins in two patients, and both the scapula and the clavicle had to be pinned to achieve proximal stabilization in two patients. In two patients, fixation was not possible and early amputation was performed. Infection was eventually eradicated in all patients, allowing for adequate soft tissue coverage of the wounds. Analysis of functional results at an average of 6 years after the injury showed a considerable degree of functional deficit in most patients.
A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bert, Christoph; Metheany, Katherine G.; Doppke, Karen
2005-09-15
External beam irradiation requires precise positioning of the target relative to the treatment planning coordinate system. A three-dimensional (3D) surface imaging system for patient positioning has recently been installed in one of our linear accelerator (linac) rooms. The device utilizes close-range photogrammetry to generate a 3D model of the patient's surface. This geometric model can be made to look like a digital camera image if wrapped with a gray-level image (texture mapping) that shows surface coloration. The system is calibrated to the linac coordinate system and has been designed as a patient setup device. To reproduce patient position in fractionatedmore » radiotherapy, the daily patient surface model is registered to a previously recorded reference surface. Using surface registration, the system calculates the rigid-body transformation that minimizes the distance between the treatment and the reference surface models in a region-of-interest (ROI). This transformation is expressed as a set of new couch coordinates at which the patient position best matches with the reference data. If respiratory motion is a concern, the surface can be obtained with a gated acquisition at a specified phase of the respiratory cycle. To analyze the accuracy of the system, we performed several experiments with phantoms to assess stability, alignment accuracy, precision of the gating function, and surface topology. The reproducibility of surface measurements was tested for periods up to 57 h. Each recorded frame was registered to the reference surface to calculate the required couch adjustment. The system stability over this time period was better than 0.5 mm. To measure the accuracy of the system to detect and quantify patient shift relative to a reference image, we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The maximum standard deviation was 0.75 mm for the three translational degrees of freedom, and less than 0.1 deg. for each rotation. Surface model precision was tested against computed tomography (CT)-derived surface topology. The root-mean-square rms of the distance between the surfaces was 0.65 mm, excluding regions where beam hardening caused artifacts in the CT data. Measurements were made to test the gated acquisition mode. The time-dependent amplitude was measured with the surface imaging system and an established respiratory gating system based on infrared (IR)-marker detection. The measured motion trajectories from both systems were compared to the known trajectory of the stage. The standard deviations of the amplitude differences to the motor trajectory were 0.04 and 0.15 mm for the IR-marker system and the 3D surface imaging system, respectively. A limitation of the surface-imaging device is the frame rate of 6.5 Hz, because rapid changes of the motion trajectory cannot be detected. In conclusion, the system is accurate and sufficiently stable to be used in the clinic. The errors computed when comparing the surface model with CT geometry were submillimeter, and deviations in the alignment and gating-signal tests were of the same magnitude.« less
Ganguly, Anasua; Kaza, Hrishikesh; Kapoor, Aditya; Sheth, Jenil; Ali, Mohammad Hasnat; Tripathy, Devjyoti; Rath, Suryasnata
The purpose of this study was to compare the characteristics of the ostium after external dacryocystorhinostomy and nonendoscopic endonasal dacryocystorhinostomy (NEN-DCR). This cross-sectional study included patients who underwent a successful external dacryocystorhinostomy or NEN-DCR and had ≥1 month follow up. Pictures of the ostium were captured with a nasal endoscope (4 mm, 30°) after inserting a lacrimal probe premarked at 2 mm. Image analyses were performed using Image J and Contour softwares. Of the 113 patients included, external dacryocystorhinostomy group had 53 patients and NEN-DCR group had 60 patients. The mean age of patients in the NEN-DCR group (38 years) was significantly (p < 0.05) lower than the external dacryocystorhinostomy group (50 years). There was no statistically significant difference (2 sample t test, p > 0.05) in mean follow up (6 vs. 4 months), maximum diameter of ostium (8 vs. 7 mm), perpendicular drawn to it (4 vs. 4 mm), area of ostium (43 vs. 36 mm), and the minimum distance between common internal punctum and edge of the ostium (1 vs. 1 mm) between the external and NEN-DCR groups. Image processing softwares offer simple and objective method to measure the ostium. While ostia are comparable in size, their relative position differs with posteriorly placed ostia in external compared with inferior in NEN-DCR.
ICDA: A Platform for Intelligent Care Delivery Analytics
Gotz, David; Stavropoulos, Harry; Sun, Jimeng; Wang, Fei
2012-01-01
The identification of high-risk patients is a critical component in improving patient outcomes and managing costs. This paper describes the Intelligent Care Delivery Analytics platform (ICDA), a system which enables risk assessment analytics that process large collections of dynamic electronic medical data to identify at-risk patients. ICDA works by ingesting large volumes of data into a common data model, then orchestrating a collection of analytics that identify at-risk patients. It also provides an interactive environment through which users can access and review the analytics results. In addition, ICDA provides APIs via which analytics results can be retrieved to surface in external applications. A detailed review of ICDA’s architecture is provided. Descriptions of four use cases are included to illustrate ICDA’s application within two different data environments. These use cases showcase the system’s flexibility and exemplify the types of analytics it enables. PMID:23304296
Malik, Adeela; Claoué, Charles
2012-12-01
Eye cosmetics such as mascara, eye shadow and eyeliner are used extensively to highlight the eyes, and are normally applied external to the ocular surface. Adverse reactions of cosmetics within the ocular surface include mild discomfort, eyelid dermatitis, pre-corneal tear film instability, and keratitis. These are attributed mainly to the preservative (benzalkonium chloride (BAC)) constituent of cosmetic product material (CPM). Transport of CPM from an external environment to any location on the ocular surface, essentially precedes the adverse interactions occurring at the location, and the control of these transport modes is therefore of clinical relevance. The inter-transport of CPM across the TF occurs due to both diffusion and drift processes. Diffusion of neutral species is driven by concentration gradients, and the drift of cationic BAC is influenced by the inherent electric field; determined by the distribution of the various ions secreted into the aqueous layer, and the negative glycocalyx charge at the mucin layer. In the presence of mucin deficiency, the corneal epithelium is exposed to invasion by both incident BAC and lipophilic species. The transport of cationic BAC across the TF may be controlled by regulating the secretion of various electrolytes at the lacrimal gland. This is of clinical significance in reducing corneal epithelial adverse effects. However, the risks of adverse effects at the corneal surface due to invasion by the lipophilic species remain. Patients with mucin deficiency, and especially those on eye ointment/drops medication, should be discouraged from using cosmetics in a way likely to contaminate the TF. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Kucharska, Agnieszka; Covaci, Adrian; Vanermen, Guido; Voorspoels, Stefan
2015-02-01
In this study, we investigated the hypothesis whether externally adsorbed and internally deposited flame retardants (FRs) in hair could be distinguished. To this extent, hair samples collected from one volunteer were exposed under controlled conditions to phosphate FR (PFR) and polybrominated diphenyl ether (PBDE) standards to mimic external contamination. Afterwards, suitable washing procedures to selectively remove contaminants from the hair surface were investigated. The samples were measured by GC-(ECNI)-MS for PBDEs and LC-(ESI+)-MS/MS for PFRs. All investigated compounds were transferred onto the hair surface. One of the most important finding was that dust particles are not mandatory to transfer compounds on the hair surface and to be able to measure high levels of compounds in human hair. To assess different protocols to selectively remove external contamination, the exposed hair samples were washed in different media before analysis: water, methanol, hexane:dichloromethane (1:1, v/v), acetone and shampoo. Results indicated that there is no washing medium able to entirely and exclusively remove external contamination. Among investigated media, methanol removed a meaningful part of the external contamination (42-105%), but the removal efficiencies differed among compounds. We therefore concluded that hair should not be washed prior to analysis and in case of visible contamination (e.g. with cosmetic products), water would be the recommended agent. Organic solvents should not be used for the washing step. Although it is impossible to distinguish external from internal exposure, hair samples may be used as valuable biomarker of human exposure, providing a measure of integral exposure. To the best of our knowledge, this is the first study which has used externally exposed hair samples to PBDEs and PFRs. Copyright © 2014 Elsevier B.V. All rights reserved.
Lenticular card: a new method for denture identification.
Colvenkar, Shreya S
2010-01-01
The need for denture marking is important for forensic and social reasons in case patients need to be identified individually. Majority of the surface marking and inclusion techniques are expensive, time consuming, and do not permit the incorporation of large amounts of information. In this article, the method to include a lenticular identification card stood out from the currently available denture marking methods in various ways. The lenticular card stores the patient's information has two or more images that can be viewed by changing the angle of view. The maxillary denture was processed according to the manufacturer's instructions. The lenticular identification card was incorporated in the external posterior buccal surface of the maxillary denture using salt and pepper technique. For testing of durability, denture with the identifier was placed in water for up to 4 months. The proposed method is simple, cheap, and can store a large amount of information, thus allowing quick identification of the denture wearer. The labels showed no sign of fading or deterioration.
Gu, Jianli; Li, Jitian; Huang, Manyu; Zhang, Zhiyong; Li, Dongsheng; Song, Guoying; Ding, Xingpo; Li, Wuyin
2014-01-01
Osteosarcoma (OS) is the most common malignant bone tumor. To identify OS-related specific proteins for early diagnosis of OS, a novel approach, surface-enhanced laser desorption/ionization-time-of-flight mass spectrometry (SELDI-TOF-MS) to serum samples from 25 OS patients, 16 osteochondroma, and 26 age-matched normal human volunteers as controls, was performed. Two proteins showed a significantly different expression in OS serum samples from control groups. Proteomic profiles and external leave-one-out cross-validation analysis showed that the correct rate of allocation, the sensitivity, and the specificity of diagnosis were 100%. These two proteins were further identified by searching the EPO-KB database, and one of the proteins identified as Serine rich region profile is involved in various cellular signaling cascades and tumor genesis. The presence of these two proteins in OS patients but absence from premalignant and normal human controls implied that they can be potential biomarkers for early diagnosis of OS.
Etiologic analysis of 100 anatomically failed dacryocystorhinostomies
Dave, Tarjani Vivek; Mohammed, Faraz Ali; Ali, Mohammad Javed; Naik, Milind N
2016-01-01
Background The aim of this study was to assess the etiological factors contributing to the failure of a dacryocystorhinostomy (DCR). Patients and methods Retrospective review was performed in 100 consecutive patients who were diagnosed with anatomically failed DCR at presentation to a tertiary care hospital over a 5-year period from 2010 to 2015. Patient records were reviewed for demographic data, type of past surgery, preoperative endoscopic findings, previous use of adjuvants such as intubation and mitomycin C, and intraoperative notes during the re-revision. The potential etiological factors for failure were noted. Results Of the 100 patients with failed DCRs, the primary surgery was an external DCR in 73 and endoscopic DCR in 27 patients. Six patients in each group had multiple revisions. The mean ages at presentation in the external and endoscopic groups were 39.41 years and 37.19 years, respectively. All patients presented with epiphora. The most common causes of failure were inadequate osteotomy (69.8% in the external group and 85.1% in the endoscopic group, P=0.19) followed by inadequate or inappropriate sac marsupialization (60.2% in the external group and 77.7% in the endoscopic group, P=0.16) and cicatricial closure of the ostium (50.6% in the external group and 55.5% in the endoscopic group, P=0.83). The least common causes such as ostium granulomas and paradoxical middle turbinate (1.37%, n=1) were noted in the external group only. Conclusion Inadequate osteotomy, incomplete sac marsupialization, and cicatricial closure of the ostium were the most common causes of failure and did not significantly differ in the external and endoscopic groups. Meticulous evaluation to identify causative factors for failure and addressing them are crucial for subsequent successful outcomes. PMID:27555748
Isotani, Shuji; Shimoyama, Hirofumi; Yokota, Isao; Noma, Yasuhiro; Kitamura, Kousuke; China, Toshiyuki; Saito, Keisuke; Hisasue, Shin-ichi; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Ukimura, Osamu; Gill, Inderbir S; Horie, Shigeo
2015-10-01
The predictive model of postoperative renal function may impact on planning nephrectomy. To develop the novel predictive model using combination of clinical indices with computer volumetry to measure the preserved renal cortex volume (RCV) using multidetector computed tomography (MDCT), and to prospectively validate performance of the model. Total 60 patients undergoing radical nephrectomy from 2011 to 2013 participated, including a development cohort of 39 patients and an external validation cohort of 21 patients. RCV was calculated by voxel count using software (Vincent, FUJIFILM). Renal function before and after radical nephrectomy was assessed via the estimated glomerular filtration rate (eGFR). Factors affecting postoperative eGFR were examined by regression analysis to develop the novel model for predicting postoperative eGFR with a backward elimination method. The predictive model was externally validated and the performance of the model was compared with that of the previously reported models. The postoperative eGFR value was associated with age, preoperative eGFR, preserved renal parenchymal volume (RPV), preserved RCV, % of RPV alteration, and % of RCV alteration (p < 0.01). The significant correlated variables for %eGFR alteration were %RCV preservation (r = 0.58, p < 0.01) and %RPV preservation (r = 0.54, p < 0.01). We developed our regression model as follows: postoperative eGFR = 57.87 - 0.55(age) - 15.01(body surface area) + 0.30(preoperative eGFR) + 52.92(%RCV preservation). Strong correlation was seen between postoperative eGFR and the calculated estimation model (r = 0.83; p < 0.001). The external validation cohort (n = 21) showed our model outperformed previously reported models. Combining MDCT renal volumetry and clinical indices might yield an important tool for predicting postoperative renal function.
Synthesis, characterization, applications, and challenges of iron oxide nanoparticles
Ali, Attarad; Zafar, Hira; Zia, Muhammad; ul Haq, Ihsan; Phull, Abdul Rehman; Ali, Joham Sarfraz; Hussain, Altaf
2016-01-01
Recently, iron oxide nanoparticles (NPs) have attracted much consideration due to their unique properties, such as superparamagnetism, surface-to-volume ratio, greater surface area, and easy separation methodology. Various physical, chemical, and biological methods have been adopted to synthesize magnetic NPs with suitable surface chemistry. This review summarizes the methods for the preparation of iron oxide NPs, size and morphology control, and magnetic properties with recent bioengineering, commercial, and industrial applications. Iron oxides exhibit great potential in the fields of life sciences such as biomedicine, agriculture, and environment. Nontoxic conduct and biocompatible applications of magnetic NPs can be enriched further by special surface coating with organic or inorganic molecules, including surfactants, drugs, proteins, starches, enzymes, antibodies, nucleotides, nonionic detergents, and polyelectrolytes. Magnetic NPs can also be directed to an organ, tissue, or tumor using an external magnetic field for hyperthermic treatment of patients. Keeping in mind the current interest in iron NPs, this review is designed to report recent information from synthesis to characterization, and applications of iron NPs. PMID:27578966
Shoulder abduction and external rotation restoration with nerve transfer.
Kostas-Agnantis, Ioannis; Korompilias, Anastasios; Vekris, Marios; Lykissas, Marios; Gkiatas, Ioannis; Mitsionis, Gregory; Beris, Alexander
2013-03-01
In upper brachial plexus palsy patients, loss of shoulder function and elbow flexion is obvious as the result of paralysed muscles innervated by the suprascapular, axillary and musculocutaneus nerve. Shoulder stabilisation, restoration of abduction and external rotation are important as more distal functions will be affected by the shoulder situation. Between 2005 and 2011, eleven patients with upper type brachial plexus palsy were operated on with triceps nerve branch transfer to anterior axillary nerve branch and spinal accessory nerve transfer to the suprascapular nerve for shoulder abduction and external rotation restoration. Nine patients met the inclusion criteria for the study. All patients were men with ages ranged from 21 to 35 years (average, 27.4 years). The interval between injury and surgery ranged from 4 to 11 months (average, 7.2 months). Atrophy of the supraspinatus, infraspinatus and deltoid muscle and subluxation at the glenohumeral joint was obvious in all patients preoperatively. During the pre-op examination all patients had at least muscle grading 4 on the triceps muscle. The mean post-operative value of shoulder abduction was 112.2° (range: 60-170°) while preoperatively none of the patients was able for abduction (p<0.001). The mean post-operative value of shoulder external rotation was 66° (range: 35-110°) while preoperatively none of them was able for external rotation (p<0.001). Postoperative values of shoulder abduction were significantly better that those of external rotation (p=0.0004). The postoperative average muscle grading for shoulder abduction according the MRC scale was 3.6±0.5 and for the shoulder external rotation was 3.2±0.4. Combined nerve transfer by using the spinal accessory nerve for suprascapular nerve neurotisation and one of the triceps nerve branches for axillary nerve and teres minor branch neurotisation is an excellent choice for shoulder abduction and external rotation restoration. Copyright © 2013 Elsevier Ltd. All rights reserved.
Fast time-of-flight camera based surface registration for radiotherapy patient positioning.
Placht, Simon; Stancanello, Joseph; Schaller, Christian; Balda, Michael; Angelopoulou, Elli
2012-01-01
This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. A novel preregistration algorithm, based on translation and rotation-invariant features representing surface structures, was developed. Using these features, corresponding three-dimensional points were computed in order to determine initial registration parameters. These parameters became a robust input to an accelerated version of the iterative closest point (ICP) algorithm for the fine-tuning of the registration result. Distance calibration and Kalman filtering were used to compensate for ToF-camera dependent noise. Additionally, the advantage of using the feature based preregistration over an "ICP only" strategy was evaluated, as well as the robustness of the rigid-transformation-based method to deformation. The proposed surface registration method was validated using phantom data. A mean target registration error (TRE) for translations and rotations of 1.62 ± 1.08 mm and 0.07° ± 0.05°, respectively, was achieved. There was a temporal delay of about 65 ms in the registration output, which can be seen as negligible considering the dynamics of biological systems. Feature based preregistration allowed for accurate and robust registrations even at very large initial displacements. Deformations affected the accuracy of the results, necessitating particular care in cases of deformed surfaces. The proposed solution is able to solve surface registration problems with an accuracy suitable for radiotherapy cases where external surfaces offer primary or complementary information to patient positioning. The system shows promising dynamic properties for its use in gating/tracking applications. The overall system is competitive with commonly-used surface registration technologies. Its main benefit is the usage of a cost-effective off-the-shelf technology for surface acquisition. Further strategies to improve the registration accuracy are under development.
Arterial chemoradiotherapy for carcinomas of the external auditory canal and middle ear.
Fujiwara, Masayuki; Yamamoto, Satoshi; Doi, Hiroshi; Takada, Yasuhiro; Odawara, Soichi; Niwa, Yasue; Ishikura, Reiichi; Kamikonya, Norihiko; Terada, Tomonori; Uwa, Nobuhiro; Sagawa, Kosuke; Hirota, Shozo
2015-03-01
The purpose of this study was to estimate the efficacy of superselective arterial chemoradiotherapy for locally advanced carcinomas of the external auditory canal and middle ear. A retrospective study of clinical data for consecutive patients with locally advanced carcinomas of the external auditory canal and middle ear. Thirteen patients with locally advanced carcinomas of the external auditory canal and middle ear (T3: one patient, T4: 12 patients) were reviewed. The median follow-up duration in the living patients was 33 months. The total dose of radiation therapy was 60 Gy using conventional fractionation. Four, five, or six courses of a superselective arterial infusion (cisplatin 50 mg) were given weekly. The overall survival and progression-free survival rates at 2 years, calculated by the Kaplan-Meier method, were 58.7% and 53.8%, respectively. No late-phase adverse effects due to chemoradiation and no adverse effects due to catheterization were observed. These results suggest that superselective arterial chemoradiation can be a treatment option for locally advanced carcinomas of the external auditory canal and middle ear. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rong, Y; Walston, S
Purpose: To evaluate the use of 3D optical surface imaging as a new surrogate for respiratory motion gated deep-inspiration breath-hold (DIBH) technique for left breast cancer patients. Methods: Patients with left-sided breast cancer after lumpectomy or mastectomy were selected as candidates for DIBH technique for their external beam radiation therapy. Treatment plans were created on both free breathing (FB) and DIBH CTs to determine whether DIBH was beneficial in reducing heart doses. The Real-time Position Management (RPM) system was used to acquire patient's breathing trace during DIBH CT acquisition and treatment delivery. The reference 3D surface models from FB andmore » DIBH CTs were generated and transferred to the “AlignRT” system for patient positioning and real-time treatment monitoring. MV Cine images were acquired for each beam as quality assurance for intra-fractional position verification. The chest wall excursions measured on these images were used to define the actual target position during treatment, and to investigate the accuracy and reproducibility of RPM and AlignRT. Results: Reduction in heart dose can be achieved for left-sided breast patients using DIBH. Results showed that RPM has poor correlation with target position, as determined by the MV Cine imaging. This indicates that RPM may not be an adequate surrogate in defining the breath-hold level when used alone. Alternatively, the AlignRT surface imaging demonstrated a better correlation with the actual CW excursion during DIBH. Both the vertical and magnitude real-time deltas (RTDs) reported by AlignRT can be used as the gating parameter, with a recommend threshold of ±3 mm and 5 mm, respectively. Conclusion: 3D optical surface imaging serves as a superior target surrogate for the left breast treatment when compared to RPM. Working together with the realtime MV Cine imaging, they ensure accurate patient setup and dose delivery, while minimizing the imaging dose to patients.« less
Regmi, Rajesh; Lovelock, D Michael; Zhang, Pengpeng; Pham, Hai; Xiong, Jianping; Yorke, Ellen D; Goodman, Karyn A; Wu, Abraham J; Mageras, Gig S
2015-06-01
To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate. Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min. Each patient had at least one implanted fiducial marker near the tumor. In all scans, abdominal displacement (Varian RPM) was recorded as the external motion signal. Purpose-built software tracked fiducials, representing internal signal, in CBCT projection images. Time lag between superior-inferior (SI) internal and anterior-posterior external signals was found by maximizing the correlation coefficient in each breathing cycle and averaging over all cycles. Time-lag-induced discrepancy between internal SI position and that predicted from the external signal (external prediction error) was also calculated. Mean ± standard deviation time lag, over all scans and patients, was 0.10 ± 0.07 s (range 0.01-0.36 s). External signal lagged the internal in 17/18 scans. Change in time lag between pre- and post-treatment CBCT was 0.06 ± 0.07 s (range 0.01-0.22 s), corresponding to 3.1% ± 3.7% (range 0.6%-10.8%) of gate width (range 1.6-3.1 s). In only one patient, change in time lag exceeded 10% of the gate width. External prediction error over all scans of all patients varied from 0.1 ± 0.1 to 1.6 ± 0.4 mm. Time lag between internal motion along SI and external signals is small compared to the treatment gate width of abdominal patients examined in this study. Change in time lag within a treatment session, inferred from pre- to post-treatment measurements is also small, suggesting that a single measurement of time lag at the session start is adequate. These findings require confirmation in a larger number of patients.
Regmi, Rajesh; Lovelock, D. Michael; Zhang, Pengpeng; Pham, Hai; Xiong, Jianping; Yorke, Ellen D.; Goodman, Karyn A.; Wu, Abraham J.; Mageras, Gig S.
2015-01-01
Purpose: To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate. Methods: Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min. Each patient had at least one implanted fiducial marker near the tumor. In all scans, abdominal displacement (Varian RPM) was recorded as the external motion signal. Purpose-built software tracked fiducials, representing internal signal, in CBCT projection images. Time lag between superior–inferior (SI) internal and anterior–posterior external signals was found by maximizing the correlation coefficient in each breathing cycle and averaging over all cycles. Time-lag-induced discrepancy between internal SI position and that predicted from the external signal (external prediction error) was also calculated. Results: Mean ± standard deviation time lag, over all scans and patients, was 0.10 ± 0.07 s (range 0.01–0.36 s). External signal lagged the internal in 17/18 scans. Change in time lag between pre- and post-treatment CBCT was 0.06 ± 0.07 s (range 0.01–0.22 s), corresponding to 3.1% ± 3.7% (range 0.6%–10.8%) of gate width (range 1.6–3.1 s). In only one patient, change in time lag exceeded 10% of the gate width. External prediction error over all scans of all patients varied from 0.1 ± 0.1 to 1.6 ± 0.4 mm. Conclusions: Time lag between internal motion along SI and external signals is small compared to the treatment gate width of abdominal patients examined in this study. Change in time lag within a treatment session, inferred from pre- to post-treatment measurements is also small, suggesting that a single measurement of time lag at the session start is adequate. These findings require confirmation in a larger number of patients. PMID:26127033
Midface distraction osteogenesis: internal vs. external devices.
Meling, T R; Høgevold, H-E; Due-Tønnessen, B J; Skjelbred, P
2011-02-01
This study compares internal and external distraction devices in the treatment of midface retrusion. 20 patients were treated with midface distraction (12 Crouzon, 4 Apert, 4 others); 12 with internal distraction (MID device), 8 with external distraction (Red or Blue device). The two groups were compared regarding operation time, peroperative blood loss and complications. The groups were comparable regarding patient age, sex, weight and diagnosis. In the MID-group, 7 of 12 patients (58%) underwent Le Fort III, 5 underwent 12 monobloc (32%). In the Blue device group, three of eight patients underwent Le Fort II (38%), three of eight underwent Le Fort III (38%), and two of eight underwent monobloc (25%). Operation time was shorter in the Blue device (mean 298 min) than in the MID group (mean 354 min). Peroperative blood loss and complication rates were similar. The internal distraction device is the 'gold standard' for treating midface retrusion. The use of an external distraction device in midface distraction osteogenesis is associated with a shorter operation time; peroperative blood loss and complications were similar. An external device affords better 3-dimensional control during the distraction process, so external distraction is preferable in patients who will tolerate this treatment. Copyright © 2010 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
External and internal anatomy of mandibular molars.
Rocha, L F; Sousa Neto, M D; Fidel, S R; da Costa, W F; Pécora, J D
1996-01-01
The external and internal anatomy of 628 extracted, mandibular first and second molars was studied. The external anatomy was studied by measuring each tooth and by observing the direction of the root curvatures from the facial surface. The internal anatomy of the pulp cavity was studied by a method of making the teeth translucent.
Reconstruction with distraction osteogenesis for juxta-articular nonunions with bone loss.
Kabata, Tamon; Tsuchiya, Hiroyuki; Sakurakichi, Keisuke; Yamashiro, Teruhisa; Watanabe, Koji; Tomita, Kasuro
2005-06-01
Nonunions of a juxta-articular lesion with bone loss, which represent a challenging therapeutic problem, were treated using external fixation and distraction osteogenesis. Seven juxta-articular nonunions (five septic and two aseptic) were treated. The location of the nonunion was the distal femur in four patients, the proximal tibia in one patient, and the distal tibia in two patients. All of them were located within 5 cm from the affected joints. Preoperative limb shortening was present in six cases, averaging 2.9 cm (range, 1-7 cm). The reconstructive procedure consisted of refreshment of the nonunion site, deformity correction, stabilization by external fixation, and lengthening to eliminate leg length discrepancy or to fill the defect. Shortening-distraction was applied to six patients and bone transport to one patient for reconstruction. Intramedullary nailing to reduce the duration of external fixation was simultaneously performed in two cases. All the patients had at least 1 year of follow-up evaluation. Osseous union without angular deformity or leg length discrepancy greater than 1 cm was achieved in all patients. The mean amount of lengthening was 5.8 cm (range, 2.2-10.0 cm). The mean external fixation period was 219 days (range, 98-317 days), and the mean external fixation index was 34.4 days/cm (range, 24.5-47.6 days/cm). All patients reported excellent pain reduction. There were no recurrences of infection in five patients with prior history of osteomyelitis. The functional results were categorized as excellent in two, good in three, and fair in two. Despite the length of postoperative external fixation, distraction osteogenesis can be a valuable alternative for the treatment of juxta-articular nonunions.
Flap noise measurements for STOL configurations using external upper surface blowing
NASA Technical Reports Server (NTRS)
Dorsch, R. G.; Reshotko, M.; Olsen, W. A.
1972-01-01
Screening tests of upper surface blowing on externally blown flaps configurations were conducted. Noise and turning effectiveness data were obtained with small-scale, engine-over-the-wing models. One large model was tested to determine scale effects. Nozzle types included circular, slot, D-shaped, and multilobed. Tests were made with and without flow attachment devices. For STOL applications the particular multilobed mixer and the D-shaped nozzles tested were found to offer little or no noise advantage over the round convergent nozzle. High aspect ratio slot nozzles provided the quietest configurations. In general, upper surface blowing was quieter than lower surface blowing for equivalent EBF models.
Carbon dioxide laser for de-epithelialization of periodontal flaps.
Centty, I G; Blank, L W; Levy, B A; Romberg, E; Barnes, D M
1997-08-01
Regeneration of mineralized and soft connective tissue components of the attachment apparatus is the main goal in the treatment of periodontal diseases. Often, apical migration of epithelium (long junctional epithelium) effectively prevents the formation of bone and connective tissue attachment after periodontal surgery. The purpose of the present study was to compare conventional periodontal surgery combined with carbon dioxide laser and conventional periodontal surgery alone with respect to epithelial elimination and degree of necrosis of mucoperiosteal flaps. After signing a consent form, five patients with at least two comparable bilateral periodontal defects needing pocket elimination surgery participated in this study. The investigators randomly divided each side into test and control sites. Each patient received oral hygiene instruction and initial therapy prior to surgery. At surgery, the test site received a sulcular incision and carbon dioxide laser de-epithelialization of the outer and inner aspects of the flap. The control group received reverse bevel incision only. The surgeon performed open flap debridement on all teeth. At the time of surgery, the surgeon did a biopsy of each site and submitted specimens for histologic evaluation. A matched pairs t-test was used to analyze the data. The results show significant differences between the carbon dioxide laser and reverse bevel incision with respect to sulcular (P < or = 0.025) and gingival (external) (P < or = 0.01) flap surface epithelial elimination and tissue necrosis (P < or = 0.005). These results should be replicated with a larger number of subjects. The carbon dioxide laser eliminated sulcular and gingival (external) epithelium without disturbing underlying connective tissue. This finding supports the concept that the carbon dioxide wavelength has little or no effect on tissues beyond the target. However, neither laser nor blade eliminated all the epithelium. Researchers observed chronic inflammation in the control and test sites, with a predominance of plasma cells. Lining the sulcular and gingival (external) lased areas, investigators found coagulation necrosis covered by fibrin and coagulated blood. The laser appears to effectively remove epithelium at the time of surgery; however, future long-term, well-controlled quantitative histologic studies are needed to evaluate the effect of repeated carbon dioxide laser de-epithelialization of the gingival (external) surface of mucoperiosteal flaps at intervals during the healing period.
OʼToole, Robert V; Gary, Joshua L; Reider, Lisa; Bosse, Michael J; Gordon, Wade T; Hutson, James; Quinnan, Stephen M; Castillo, Renan C; Scharfstein, Daniel O; MacKenzie, Ellen J
2017-04-01
The treatment of high-energy open tibia fractures is challenging in both the military and civilian environments. Treatment with modern ring external fixation may reduce complications common in these patients. However, no study has rigorously compared outcomes of modern ring external fixation with commonly used internal fixation approaches. The FIXIT study is a prospective, multicenter randomized trial comparing 1-year outcomes after treatment of severe open tibial shaft fractures with modern external ring fixation versus internal fixation among men and women of ages 18-64. The primary outcome is rehospitalization for major limb complications. Secondary outcomes include infection, fracture healing, limb function, and patient-reported outcomes including physical function and pain. One-year treatment costs and patient satisfaction will be compared between the 2 groups, and the percentage of Gustilo IIIB fractures that can be salvaged without soft tissue flap among patients receiving external fixation will be estimated.
Gros, Sébastien A A; Xu, William; Roeske, John C; Choi, Mehe; Emami, Bahman; Surucu, Murat
2017-03-01
To develop a novel method to monitor external anatomical changes in head and neck cancer patients in order to triage possible adaptive radiotherapy needs. The presented approach aims to provide information on internal anatomical changes based on variations observed in external anatomy. Setup Cone Beam Computed Tomography (CBCT) images are processed to produce an accurate external contour of the patient's skin. After registering the CBCTs to the reference planning CT, the external contours from each CBCT are transferred to the initial - first week - CBCT. Contour radii, defined as the distances between an external contour and the isocenter projection in each CBCT slice, are calculated for each scan over the full 360 degrees. The changes in external anatomy are then quantified by the difference in radial distance between the external contours of any secondary CBCT relative to the initial CBCT. Finally, the radial difference is displayed in cylindrical coordinates as a 2D intensity map to highlight regions of interests with significant changes. Weekly CBCT scans from 15 head and neck patients were retrospectively analyzed to demonstrate the utility of this approach as a proof of principle. External changes suggested by the 2D radial difference map of an example patient after 23 fractions were then correlated with the changes in the gross tumor volumes and organs at risks. The resulting dosimetric effects were evaluated. An interactive standalone software application has been developed to facilitate the generation and the interpretation of the 2D intensity map. The 2D radial difference maps provided qualitative and quantitative information, such as the location and the magnitude of external contour changes and the rate at which these deviations occur. Out of the 15 patients, 10 presented clear evidence of general external volume shrinkage due to weight loss, and nine patients had at least one site of local shrinkage. Only two patients showed no signs of anatomical change during their entire treatment course. For the example patient, the mean (±σ) radial difference was 6.7 (±3.0) mm for the left parotid and 7.3 (±2.5) mm for the right parotid. The mean dose to the left and right parotids increased from 20.1 Gy to 30 Gy and from 16.3 Gy to 29.6 Gy, respectively. This novel method provides an efficient tool to visualize 3D external anatomical changes on a single 2D map. It quickly pinpoints the location of differences in anatomy during the course of radiotherapy, which can help physicians determine if a treatment plan needs to be adapted. The interactive graphic user interface developed in this study will be evaluated in an adaptive radiotherapy workflow for head and neck patients in a future prospective trial. © 2016 American Association of Physicists in Medicine.
[Results of femoral lengthening over an intramedullary nail and external fixator].
Jasiewicz, Barbara; Kacki, Wojciech; Tesiorowski, Maciej; Potaczek, Tomasz
2008-01-01
Current techniques of operative limb lengthening usually are based on distraction osteogenesis. One of the techniques is limb lengthening over an intramedullary nail. The goal of this study is to evaluate the results of femoral lengthening over an intramedullary nail. Between 1999 and 200619 femoral "over nail" lengthenings were performed. There were 7 males and 12 females. Mean patients' age at surgery was 15.8 years, and mean initial femoral shortening was 5.1 cm. Operative technique consisted of one-stage implantation of intramedullary nail and external fixator. Ilizarov apparatus was used in 9 patients, monolateral fixator in 10 cases--ORTHOFIX in 9 patients, Wagner fixator--in 1 patient. Intramedullary nail was locked proximally with screws or Schanz pins from external fixator. After distraction phase, external fixator was removed and distal locking screws were applied. Evaluation criteria: obtained lengthening, time of external fixator, treatment time, healing index, external fixation index, range of motion in hip and knee joints and complications according to Paley. The mean lengthening was 4.6 cm, and mean distraction time was 66.6 days. Mean time of external fixation was 115.5 days, and external fixation index was 26.2 days for centimeter. Healing index was 36.9 days for centimeter. In cases with monolateral fixator, healing index did not differ with the whole group. During treatment 18 complications occurred, for a rate of 0.9 complication per segment. Lengthening over an intramedullary nail reduces the time of external fixator. Over nail femoral lengthening can prevent axis deviation following regenerate bending. Complication rate is similar to lengthenings with the classic Ilizarov technique. There are no differences in the treatment time in relation to the type of external fixator.
Liquid nitrogen cryotherapy for surface eye disease (an AOS thesis).
Fraunfelder, Frederick Web
2008-01-01
To evaluate the effects of new treatments with liquid nitrogen cryotherapy on some external eye conditions. In this retrospective case study, 6 separate series from a single tertiary care referral center practice are described. Liquid nitrogen cryotherapy was used to treat conjunctival amyloidosis, primary pterygia, recurrent pterygia, advancing wavelike epitheliopathy (AWLE), superior limbic keratoconjunctivitis (SLK), and palpebral vernal keratoconjunctivitis (VKC). The main outcome measure was the resolution of the disease process after treatment. Four patients with primary localized conjunctival amyloidosis were treated with liquid nitrogen cryotherapy. Two of them had recurrence of the amyloidosis, which cleared with subsequent treatment. Eighteen patients with primary pterygia had excision and cryotherapy with 1 recurrence. Of 6 subjects who presented with recurrent pterygia, 4 had a second recurrence after excision and cryotherapy. In 5 patients with AWLE, the condition resolved within 2 weeks without recurrence or the need for subsequent cryotherapy. Four patients with SLK were treated with liquid nitrogen cryotherapy. Disease recurred in 2 patients and 3 of 7 eyes, although subsequent cryotherapy eradicated SLK in all cases. Two patients and 3 eyelids with palpebral VKC were treated with liquid nitrogen cryotherapy. VKC recurred in all cases. Liquid nitrogen cryotherapy to the surface of the eye is effective in treating AWLE, and SLK. Excision followed by cryotherapy is successful in treating conjunctival amyloidosis and primary pterygia Liquid nitrogen cryotherapy is unsuccessful in the treatment of recurrent pterygia and VKC.
Emara, Khaled; El Moatasem, El Hussein; El Shazly, Ossama
2011-12-01
Complex foot deformity is a multi-planar foot deformity with many etiologic factors. Different corrective procedures using Ilizarov external fixation have been described which include, soft tissue release, V-osteotomy, multiple osteotomies and triple fusion. In this study we compare the results of two groups of skeletally mature patients with complex foot deformity who were treated by two different protocols. The first group (27 patients, 29 feet) was treated by triple fusion fixed by Ilizarov external fixator until union. The second group (29 patients, 30 feet), was treated by triple fusion with initial fixation by Ilizarov external fixation until correction of the deformity was achieved clinically, and then the Ilizarov fixation was replaced by internal fixation using percutaneous screws. Both groups were compared as regard the surgical outcome and the incidence of complications. There was statistically significant difference between the two groups regarding duration of external fixation and duration of casting with shorter duration in the group 2. Also there was statistically significant difference between both groups regarding pin tract infection with less incidence in group 2. Early removal of Ilizarov external fixation after correction of the deformity and percutaneous internal fixation using 6.5 cannulated screws can shorten the duration of treatment and be more comfortable for the patient with a low risk of recurrence or infection. Copyright © 2010 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lazanja, David; Boozer, Allen
2006-10-01
Given the total magnetic field on a toroidal plasma surface, a method for decomposing the field into a part due to internal currents (often the plasma) and a part due to external currents is presented. The method exploits Laplace theory which is valid in the vacuum region between the plasma surface and the chamber walls. The method is developed for the full three dimensional case which is necessary for studying stellarator plasma configurations. A change in the plasma shape is produced by the total normal field perturbation on the plasma surface. This method allows a separation of the total normal field perturbation into a part produced by external currents and a part produced by the plasma response. There are immediate applications to coil design. The computational procedure is based on Merkel's 1986 work on vacuum field computations. Several test cases are presented for toroidal surfaces which verify the method and computational robustness of the code.
Dalla Paola, Luca; Brocco, Enrico; Ceccacci, Tanja; Ninkovic, Sasa; Sorgentone, Sara; Marinescu, Maria Grazia; Volpe, Antonio
2009-11-01
Charcot neuroarthropathy of the foot/ankle is a devastating complication of diabetes. Along with neuroarthropathy, osteomyelitis can occur which can result in amputation. This prospective study evaluated a limb salvage procedure as an alternative to amputation through surgical treatment of osteomyelitis of the midfoot or the ankle and stabilization with external fixation. Forty-five patients with Charcot arthropathy and osteomyelitis underwent debridement and attempted fusion with an external fixator. Chart and radiograph review was performed to assess the success of the fusion and eradication of infection. Out of 45 patients, 39 patients healed using emergent surgery to drain an acute manifestation of the infection while maintaining the fixation for an average of 25.7 weeks. Two patients were treated with intramedullary nail in a subsequent surgical procedure. In four patients, the infection could not be controlled, therefore a major amputation was carried out. For select patients, external fixation proved to be a reasonable alternative to below-knee amputation.
Clinical experience of external -route retinal detachment surgery under a surgical microscope.
Xu, Hui
2014-03-01
To evaluate the efficacy of external-route retinal reattachment surgery under a surgical microscope. A total of 86 patients (86 eyes) with rhegmatogenous retinal detachment underwent external-route retinal detachment surgery under a surgical microscope. Drainage of subretinal fluid, transscleral cryotherapy, scleral buckling, and intravitreal injection of gas were performed intraoperatively. Among 85 patients, 81 achieved postoperative retinal re-attachment after the first surgery and 5 after two surgeries. The visual acuity was elevated in 67 patients, unchanged in 15, and decreased in 4. External-route retinal reattachment surgery under a surgical microscope is a convenient procedure for physicians to master and worthy of widespread application in clinical settings.
NASA Astrophysics Data System (ADS)
Dammertz, K.; Saier, A. M.; Marti, O.; Amirkhani, M.
2014-04-01
External stimuli such as vapours and electric fields can be used to manipulate the formation of AB-diblock copolymers on surfaces. We study the conformational variation of PS-b-PMMA (polystyrene-block-poly(methyl methacrylate)), PS and PMMA adsorbed on mica and their response to saturated water or chloroform atmospheres. Using specimens with only partial polymer coverage, new unanticipated effects were observed. Water vapour, a non-solvent for all three polymers, was found to cause high surface mobility. In contrast, chloroform vapour (a solvent for all three polymers) proved to be less efficient. Furthermore, the influence of an additional applied electric field was investigated. A dc field oriented parallel to the sample surface induces the formation of polymer islands which assemble into wormlike chains. Moreover, PS-b-PMMA forms octopus-like micelles (OLMs) on mica. Under the external stimuli mentioned above, the wormlike formations of OLMs are able to align in the direction of the external electric field. In the absence of an electric field, the OLMs disaggregate and exhibit phase separated structures under chloroform vapour.
Does pediatric body mass index affect surgical outcomes of lower-extremity external fixation?
Fedorak, Graham T; Cuomo, Anna V; Otsuka, Norman Y
2015-06-01
Obese patients are highly prevalent in the pediatric orthopaedic surgeon's practice and obesity is an increasing issue in the United States. Increased body mass index (BMI) has been associated with increased complications in pediatric orthopaedic patients, but no study has looked specifically at external fixation. The purpose of this study was to determine whether obesity is a risk factor for increased complications in lower-extremity procedures requiring external fixation. A retrospective chart review was conducted of pediatric patients who underwent external fixation as definitive operative treatment for any condition at a tertiary care hospital over a 15-year period. Patients were grouped into normal weight, overweight, and obese based on Centers for Disease Control definitions. All orthopaedic complications were recorded. A total of 208 patients with a mean age of 11.2 years were identified. Ninety-four children were obese at the 95th percentile BMI or higher, 22 were overweight and 93 were normal weight. External fixation was applied to the tibia in 82 cases, to the femur in 77 and to both in 49. Mean duration of fixation was 160 days (range, 31 to 570 d) and patients were followed for a mean of 3.9 years (range, 1.0 to 12.0 y). There was no statistically significant difference in the rate of complications between the 3 groups (P=0.61). In the obese group complications occurred in 68.1% versus 66.7% in the overweight group and 61.3% in normal weight. In the setting of external fixator use for lower-extremity pathology in pediatric patients, there is no association between an increase in complications and obesity as defined by BMI. Complication rates are high when external fixation is utilized for the lower extremity, however, patients and families should not be counseled that increased BMI will add to the burden of orthopaedic complications in this situation. Level II-prognostic.
Photographic Analysis Technique for Assessing External Tank Foam Loss Events
NASA Technical Reports Server (NTRS)
Rieckhoff, T. J.; Covan, M.; OFarrell, J. M.
2001-01-01
A video camera and recorder were placed inside the solid rocket booster forward skirt in order to view foam loss events over an area on the external tank (ET) intertank surface. In this Technical Memorandum, a method of processing video images to allow rapid detection of permanent changes indicative of foam loss events on the ET surface was defined and applied to accurately count, categorize, and locate such events.
NASA Technical Reports Server (NTRS)
Carlson, J. R.; Pendergraft, O. C., Jr.; Burley, J. R., II
1986-01-01
A three-dimensional subsonic aerodynamic panel code (VSAERO) was used to predict the effects of upper and lower external nozzle flap geometry on the external afterbody/nozzle pressure coefficient distributions and external nozzle drag of nonaxisymmetric convergent-divergent exhaust nozzles having parallel external sidewalls installed on a generic twin-engine high performance aircraft model. Nozzle static pressure coefficient distributions along the upper and lower surfaces near the model centerline and near the outer edges (corner) of the two surfaces were calculated, and nozzle drag was predicted using these surface pressure distributions. A comparison between the theoretical predictions and experimental wind tunnel data is made to evaluate the utility of the code in calculating the flow about these types of non-axisymmetric afterbody configurations. For free-stream Mach numbers of 0.60 and 0.90, the conditions where the flows were attached on the boattails yielded the best comparison between the theoretical predictions and the experimental data. For the Boattail terminal angles of greater than 15 deg., the experimental data for M = 0.60 and 0.90 indicated areas of separated flow, so the theoretical predictions failed to match the experimental data. Even though calculations of regions of separated flows are within the capabilities of the theoretical method, acceptable solutions were not obtained.
Photoelectron emission from LiF surfaces by ultrashort electromagnetic pulses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Acuna, M. A.; Gravielle, M. S.; Departamento de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires
2011-03-15
Energy- and angle-resolved electron emission spectra produced by incidence of ultrashort electromagnetic pulses on a LiF(001) surface are studied by employing a distorted-wave method named the crystal surface-Volkov (CSV) approximation. The theory makes use of the Volkov phase to describe the action of the external electric field on the emitted electron, while the electron-surface interaction is represented within the tight-binding model. The CSV approach is applied to investigate the effects introduced by the crystal lattice when the electric field is oriented parallel to the surface plane. These effects are essentially governed by the vector potential of the external field, whilemore » the influence of the crystal orientation was found to be negligible.« less
Prabhakar, Ramachandran
2012-01-01
Source to surface distance (SSD) plays a very important role in external beam radiotherapy treatment verification. In this study, a simple technique has been developed to verify the SSD automatically with lasers. The study also suggests a methodology for determining the respiratory signal with lasers. Two lasers, red and green are mounted on the collimator head of a Clinac 2300 C/D linac along with a camera to determine the SSD. A software (SSDLas) was developed to estimate the SSD automatically from the images captured by a 12-megapixel camera. To determine the SSD to a patient surface, the external body contour of the central axis transverse computed tomography (CT) cut is imported into the software. Another important aspect in radiotherapy is the generation of respiratory signal. The changes in the lasers separation as the patient breathes are converted to produce a respiratory signal. Multiple frames of laser images were acquired from the camera mounted on the collimator head and each frame was analyzed with SSDLas to generate the respiratory signal. The SSD as observed with the ODI on the machine and SSD measured by the SSDlas software was found to be within the tolerance limit. The methodology described for generating the respiratory signals will be useful for the treatment of mobile tumors such as lung, liver, breast, pancreas etc. The technique described for determining the SSD and the generation of respiratory signals using lasers is cost effective and simple to implement. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, X., E-mail: xzm0005@auburn.edu; Maurer, D. A.; Knowlton, S. F.
2015-12-15
Non-axisymmetric free-boundary equilibrium reconstructions of stellarator plasmas are performed for discharges in which the magnetic configuration is strongly modified by ohmically driven plasma current. These studies were performed on the compact toroidal hybrid device using the V3FIT reconstruction code with a set of 50 magnetic diagnostics external to the plasma. With the assumption of closed magnetic flux surfaces, the reconstructions using external magnetic measurements allow accurate estimates of the net toroidal flux within the last closed flux surface, the edge safety factor, and the plasma shape of these highly non-axisymmetric plasmas. The inversion radius of standard sawteeth is used tomore » infer the current profile near the magnetic axis; with external magnetic diagnostics alone, the current density profile is imprecisely reconstructed.« less
NASA Astrophysics Data System (ADS)
Ma, X.; Maurer, D. A.; Knowlton, S. F.; ArchMiller, M. C.; Cianciosa, M. R.; Ennis, D. A.; Hanson, J. D.; Hartwell, G. J.; Hebert, J. D.; Herfindal, J. L.; Pandya, M. D.; Roberds, N. A.; Traverso, P. J.
2015-12-01
Non-axisymmetric free-boundary equilibrium reconstructions of stellarator plasmas are performed for discharges in which the magnetic configuration is strongly modified by ohmically driven plasma current. These studies were performed on the compact toroidal hybrid device using the V3FIT reconstruction code with a set of 50 magnetic diagnostics external to the plasma. With the assumption of closed magnetic flux surfaces, the reconstructions using external magnetic measurements allow accurate estimates of the net toroidal flux within the last closed flux surface, the edge safety factor, and the plasma shape of these highly non-axisymmetric plasmas. The inversion radius of standard sawteeth is used to infer the current profile near the magnetic axis; with external magnetic diagnostics alone, the current density profile is imprecisely reconstructed.
Ma, X.; Maurer, D. A.; Knowlton, Stephen F.; ...
2015-12-22
Non-axisymmetric free-boundary equilibrium reconstructions of stellarator plasmas are performed for discharges in which the magnetic configuration is strongly modified by ohmically driven plasma current. These studies were performed on the compact toroidal hybrid device using the V3FIT reconstruction code with a set of 50 magnetic diagnostics external to the plasma. With the assumption of closed magnetic flux surfaces, the reconstructions using external magnetic measurements allow accurate estimates of the net toroidal flux within the last closed flux surface, the edge safety factor, and the plasma shape of these highly non-axisymmetric plasmas. Lastly, the inversion radius of standard saw-teeth is usedmore » to infer the current profile near the magnetic axis; with external magnetic diagnostics alone, the current density profile is imprecisely reconstructed.« less
Knee arthrodesis with circular external fixation.
Garberina, M J; Fitch, R D; Hoffmann, E D; Hardaker, W T; Vail, T P; Scully, S P
2001-01-01
Knee arthrodesis can enable limb salvage in patients with disability secondary to trauma, infected total knee arthroplasty, pyarthrosis, and other complications. Historically, intramedullary nailing has resulted in the highest overall knee fusion rates. However, intramedullary nailing is relatively contraindicated in the presence of active infection. Nineteen patients who underwent knee arthrodesis with circular external fixation were studied retrospectively. Postoperative radiographs were evaluated for evidence of bony fusion, which was defined as trabecular bridging between the femur and tibia. Patients were interviewed and graded using the functional assessment portion of the Knee Society clinical rating system. Fusion was successful in 13 of 19 (68%) patients. Overall, patients spent an average of 4 months 8 days wearing the circular external fixator. Average time to radiographic and clinical evidence of arthrodesis (defined as lack of motion across the fusion site) was 4 months 18 days. No patient with successful fusion considered himself or herself housebound. All but one of these patients require some form of assistive device for ambulation. Complications occurred in 16 of 19 (84%) patients overall. Superficial pin tract infection (55%) and nonunion (32%) were the most common. Circular external fixation is an effective method for obtaining knee arthrodesis in patients who are not good candidates for intramedullary nailing.
Farahati, J; Reiners, C; Stuschke, M; Müller, S P; Stüben, G; Sauerwein, W; Sack, H
1996-01-01
The role of adjuvant external radiotherapy in the survival of patients with differentiated thyroid cancer (DTC) is controversial. To our knowledge, no attempt has been undertaken thus far to assess the impact of this therapy with respect to the papillary and follicular types of thyroid cancer as separate entities. Between 1979 and 1992, 238 patients with differentiated papillary thyroid cancer (PTC) and follicular thyroid cancer (FTC) with Stage pT4 have been treated and followed in our clinic. One hundred sixty-nine patients free of metastases at the final staging, which was performed after the second radioiodine therapy, were included in this study. The standard treatment comprised total thyroidectomy, ablative radioiodine therapy, and thyroid-stimulating hormone-suppressive therapy with levothyroxin. Ninety-nine patients free of disease after the final staging received additional external radiotherapy to the neck (with a dose of 50-60 Gy), whereas the remaining 70 patients were treated with the standard treatment protocol only. Distributions of age, sex, and follow-up time were comparable in both irradiated and nonirradiated groups. Multivariate analysis of the influence of age, sex, histologic subtype, and lymph node status as well as of external radiotherapy on the time to first locoregional and distant failure (LDF), and the time to locoregional recurrence (LR), was accomplished using Cox's proportional hazard model. In patients with DTC, external radiotherapy was a predictive factor for improvement of both LR (P = 0.004) and locoregional and distant failure (P = 0.0003). When the time to first locoregional and distant failure was calculated separately for patients with PTC and FTC, there was a significant difference in the PTC group in favor of irradiated patients (P = 0.0001), whereas there was no effect of external radiotherapy in the FTC group (P = 0.38). Further analyses disclosed that this effect was significantly present only in patients with PTC and lymph node involvement (P = 0.002), whereas those without lymph node involvement did not benefit from an additional adjuvant radiotherapy (P = 0.27). Because none of the patients younger than age 40 years died due to the disease nor had progressive disease during follow-up, we reassessed our results in patients older than age 40 years. The effect of external radiotherapy could be confirmed in this subgroup of patients (P = 0.0009) and in the subgroup of lymph node positive patients older than age 40 years with invasive PTC (P = 0.01). In addition to total thyroidectomy, treatment with radioiodine, and TSH-suppressive therapy with thyroid hormone, adjuvant external radiotherapy improves the recurrence-free survival in patients older than age 40 years with invasive PTC and lymph node involvement.
2009-01-01
Background The lack of recovery of active external rotation of the shoulder is an important problem in children suffering from brachial plexus lesions involving the suprascapular nerve. The accessory nerve neurotization to the suprascapular nerve is a standard procedure, performed to improve shoulder motion in patients with brachial plexus palsy. Methods We operated on 65 patients with obstetric brachial plexus palsy (OBPP), aged 5-35 months (average: 19 months). We assessed the recovery of passive and active external rotation with the arm in abduction and in adduction. We also looked at the influence of the restoration of the muscular balance between the internal and the external rotators on the development of a gleno-humeral joint dysplasia. Intraoperatively, suprascapular nerve samples were taken from 13 patients and were analyzed histologically. Results Most patients (71.5%) showed good recovery of the active external rotation in abduction (60°-90°). Better results were obtained for the external rotation with the arm in abduction compared to adduction, and for patients having only undergone the neurotization procedure compared to patients having had complete plexus reconstruction. The neurotization operation has a positive influence on the glenohumeral joint: 7 patients with clinical signs of dysplasia before the reconstructive operation did not show any sign of dysplasia in the postoperative follow-up. Conclusion The neurotization procedure helps to recover the active external rotation in the shoulder joint and has a good prevention influence on the dysplasia in our sample. The nerve quality measured using histopathology also seems to have a positive impact on the clinical results. PMID:19744351
Ogawa, Kazuhiko; Nakamura, Katsumasa; Onishi, Hiroshi; Koizumi, Masahiko; Sasaki, Tomonari; Araya, Masayuki; Miyabe, Yuuki; Otani, Yuuki; Teshima, Teruki
2006-01-01
The influence of age on the patterns and outcomes of external beam radiotherapy for clinically localized prostate cancer patients was examined. The Japanese Patterns of Care Study surveys were used to compare the processes and outcomes of radical external beam radiotherapy in 140 elderly patients (>75 years old) and 304 younger patients (<75 years old). Although the Karnofsky performance status was significantly different between elderly and younger patients, there were no significant differences in disease characteristics such as pretreatment PSA level, differentiation, Gleason combined score and clinical T stage. There were also no significant differences in the treatment characteristics such as CT-based treatment planning, conformal therapy, total radiation doses (both a median of 66.0 Gy) and hormonal therapy usage. Moreover, no significant differences in overall survival, biochemical relapse-free survival and late toxicity rates were observed between elderly and younger patients. Age did not influence the disease characteristics, patterns of external beam radiotherapy, survival and late toxicities for clinically localized prostate cancer patients. Therefore, radiotherapy could represent an important treatment modality for elderly patients as well as for younger ones.
Abdel Hakim, Mahmoud A; Abdalla, Ahmed A; Saad, Ismail R; ElSheemy, Mohammed S; El Feel, Ahmed S; Salem, Hosni K; Abdel Hakim, Amr M
2016-06-01
To prospectively compare the use of external ureteric stents with internal JJ stenting of the uretero-ileal anastomosis in patients undergoing laparoscopic radical cystectomy (LRC) with a Y-shaped ileal orthotopic neobladder (ON). The study included 69 patients undergoing LRC with ON. Patients were grouped according to the type of uretero-ileal stents used. An external ureteric stent was used in Group A (33 patients) and a JJ stent was used in Group B (36). We prospectively compared the duration of hospital stay, the incidence of short- and intermediate-term complications in the two study groups. The mean (SD) follow-up periods were 29.18 (3.94) and 28.19 (3.37) months for patients in Groups A and B, respectively. Perioperative patient characteristics were comparable in the two study groups. The use of JJ stenting was associated with a shorter hospital stay compared with external stenting, at a mean (SD) of 14.63 (3.74) and 6.8 (3.03) days in Groups A and B, respectively (P < 0.001). The incidence of urinary leakage was comparable in the two study groups, at 6.1% in Group A vs 8.3% in Group B (P = 1.0). Strictures of the uretero-ileal anastomosis occurred in two patients (6%) in Group A and confirmed by intravenous urography. All strictures were treated with antegrade JJ fixation. JJ stents could be used as an effective alternative to external ureteric stents to support the uretero-ileal anastomosis. JJ stenting is associated with a shorter hospital stay and similar complication rates compared with external stenting in patients undergoing LRC with ON.
Distraction-free ankle arthroscopy for anterolateral impingement.
Rouvillain, Jean Louis; Daoud, Wael; Donica, Adrian; Garron, Emmanuel; Uzel, André Pierre
2014-08-01
The origin of chronic pain after external ankle sprain is better known with arthroscopy's contribution. Chronic hypertrophic synovitis of the anterolateral ankle region is seemingly the cause, resulting in "anterolateral ankle impingement." But is partial synovectomy with fibrosis resection under arthroscopy always possible without any distraction? Are results affected? This retrospective study concerned only patients with soft tissue ankle impingement. All cases with bone and joint diseases were excluded. The final sample of 24 patients had a mean age of 35 years (21-54 years) and presented anterolateral mechanical pain associated with oedema following external ankle sprain. Medical and rehabilitative treatment was undertaken for more than 6 months before arthroscopy. Average time between trauma and arthroscopy was 21 months (5-60 months). Clinical examination revealed no ankle instability or laxity. Debridement with joint lavage was systematically performed under arthroscopy without any distraction. Average patient follow-up was 22 months (12-92 months). All patients had a good Kitaoka score, with 22 patients registering excellent results. There were no septic complications or algodystrophy. Two transient hypoesthesias were observed in the dorsal surface and lateral border of the foot with full postoperative recovery at 6 months. Distraction was never used and simple dorsiflexion was sufficient to perform arthroscopic debridement. In this study, anterolateral ankle impingement diagnosis was primarily clinical. Arthroscopic treatment yielded significant benefits on pain, oedema and resumption of sport activities. Arthroscopic treatment of anterolateral ankle impingements is thus possible with simple dorsiflexion and no distraction, resulting in a possible decrease in complication rates. Level of evidence Retrospective cohort study, Level IV.
Mechanisms of postprandial abdominal bloating and distension in functional dyspepsia.
Burri, Emanuel; Barba, Elizabeth; Huaman, Jose Walter; Cisternas, Daniel; Accarino, Anna; Soldevilla, Alfredo; Malagelada, Juan-R; Azpiroz, Fernando
2014-03-01
Patients with irritable bowel syndrome and abdominal bloating exhibit abnormal responses of the abdominal wall to colonic gas loads. We hypothesised that in patients with postprandial bloating, ingestion of a meal triggers comparable abdominal wall dyssynergia. Our aim was to characterise abdominal accommodation to a meal in patients with postprandial bloating. A test meal (0.8 kcal/ml nutrients plus 27 g/litre polyethylenglycol 4000) was administered at 50 ml/min as long as tolerated in 10 patients with postprandial bloating (fulfilling Rome III criteria for postprandial distress syndrome) and 12 healthy subjects, while electromyographic (EMG) responses of the anterior wall (upper and lower rectus, external and internal oblique via bipolar surface electrodes) and the diaphragm (via six ring electrodes over an oesophageal tube in the hiatus) were measured. Means +/- SD were calculated. Healthy subjects tolerated a meal volume of 913±308 ml; normal abdominal wall accommodation to the meal consisted of diaphragmatic relaxation (EMG activity decreased by 15±6%) and a compensatory contraction (25±9% increase) of the upper abdominal wall muscles (upper rectus and external oblique), with no changes in the lower anterior muscles (lower rectus and internal oblique). Patients tolerated lower volume loads (604±310 ml; p=0.030 vs healthy subjects) and developed a paradoxical response, that is, diaphragmatic contraction (14±3% EMG increment; p<0.01 vs healthy subjects) and upper anterior wall relaxation (9±4% inhibition; p<0.01 vs healthy subjects). In functional dyspepsia, postprandial abdominal distension is produced by an abnormal viscerosomatic response to meal ingestion that alters normal abdominal accommodation.
2018-01-01
ABSTRACT The hospital environment is a potential reservoir of bacteria with plasmids conferring carbapenem resistance. Our Hospital Epidemiology Service routinely performs extensive sampling of high-touch surfaces, sinks, and other locations in the hospital. Over a 2-year period, additional sampling was conducted at a broader range of locations, including housekeeping closets, wastewater from hospital internal pipes, and external manholes. We compared these data with previously collected information from 5 years of patient clinical and surveillance isolates. Whole-genome sequencing and analysis of 108 isolates provided comprehensive characterization of blaKPC/blaNDM-positive isolates, enabling an in-depth genetic comparison. Strikingly, despite a very low prevalence of patient infections with blaKPC-positive organisms, all samples from the intensive care unit pipe wastewater and external manholes contained carbapenemase-producing organisms (CPOs), suggesting a vast, resilient reservoir. We observed a diverse set of species and plasmids, and we noted species and susceptibility profile differences between environmental and patient populations of CPOs. However, there were plasmid backbones common to both populations, highlighting a potential environmental reservoir of mobile elements that may contribute to the spread of resistance genes. Clear associations between patient and environmental isolates were uncommon based on sequence analysis and epidemiology, suggesting reasonable infection control compliance at our institution. Nonetheless, a probable nosocomial transmission of Leclercia sp. from the housekeeping environment to a patient was detected by this extensive surveillance. These data and analyses further our understanding of CPOs in the hospital environment and are broadly relevant to the design of infection control strategies in many infrastructure settings. PMID:29437920
External fixation of "intertrochanteric" fractures.
Gani, Naseem Ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool
2009-10-10
In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with "intertrochanteric" fractures remain unsuita ble for open reduction and internal fixation.The aim of this study was to analyze the results of external fixation of "intertrochanteric" fractures in high-risk geriatric patients in a developing country.The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58-90 years) with "intertrochanteric" fractures, in whom external fixation was performed, are reported.Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients.This study demonstrated that external fixation of "intertrochantric" fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country.
Scoliosis curve type classification using kernel machine from 3D trunk image
NASA Astrophysics Data System (ADS)
Adankon, Mathias M.; Dansereau, Jean; Parent, Stefan; Labelle, Hubert; Cheriet, Farida
2012-03-01
Adolescent idiopathic scoliosis (AIS) is a deformity of the spine manifested by asymmetry and deformities of the external surface of the trunk. Classification of scoliosis deformities according to curve type is used to plan management of scoliosis patients. Currently, scoliosis curve type is determined based on X-ray exam. However, cumulative exposure to X-rays radiation significantly increases the risk for certain cancer. In this paper, we propose a robust system that can classify the scoliosis curve type from non invasive acquisition of 3D trunk surface of the patients. The 3D image of the trunk is divided into patches and local geometric descriptors characterizing the surface of the back are computed from each patch and forming the features. We perform the reduction of the dimensionality by using Principal Component Analysis and 53 components were retained. In this work a multi-class classifier is built with Least-squares support vector machine (LS-SVM) which is a kernel classifier. For this study, a new kernel was designed in order to achieve a robust classifier in comparison with polynomial and Gaussian kernel. The proposed system was validated using data of 103 patients with different scoliosis curve types diagnosed and classified by an orthopedic surgeon from the X-ray images. The average rate of successful classification was 93.3% with a better rate of prediction for the major thoracic and lumbar/thoracolumbar types.
Percutaneous management of postoperative bile leaks with an ethylene vinyl alcohol copolymer (Onyx).
Uller, W; Müller-Wille, R; Loss, M; Hammer, S; Schleder, S; Goessmann, H; Wiggermann, P; Stroszczynski, C; Wohlgemuth, W A
2013-12-01
The management of postoperative bile leakage is challenging especially if the leak rises from the cut surface of the liver and endoscopic treatment fails. Percutaneous transhepatic treatment of bile leaks with biliary drainage is accepted but often requires long-term placement of the drains and is associated with treatment failures. This series evaluates selective embolization of bile ducts with an ethylene vinyl alcohol copolymer (Onyx) in patients with postoperative bile leaks as an alternative treatment option. Between January and September 2012, five consecutive patients with persistent postoperative bile leaks underwent percutaneous transhepatic Onyx application and were analyzed regarding procedural management, complications and success rates. The persistent bile leaks were situated at the cystic stump (after cholecystectomy, n = 2), at the cut surface of the liver (after extended liver resection, n = 2) and at the surface of the liver after surgical exploration and perihepatic abscess (n = 1). Bile drainage alone (endoscopic or percutaneous) failed in all patients and open redo-surgery was deemed potentially harmful. Bilomas were externally drained in all patients before Onyx application. For the closure of bile leaks, Onyx was injected through a microcatheter in a previously built coil nest to keep Onyx in place. All bile leaks were initially closed immediately. In the 2nd week after Onyx embolization, 2 patients showed recurrent small bile leaks without clinical symptoms. In the 4th week after Onyx application, all leaks were closed. No complications occurred. All leaking bile ducts were initially closed immediately after Onyx application. In the 2nd week after Onyx application, 2 patients showed small bile leaks without clinical symptoms. All leaks were closed in the 4th week after Onyx application. © Georg Thieme Verlag KG Stuttgart · New York.
Qiu, Wen-Jun; Li, Yi-Fan; Ji, Yun-Han; Xu, Wei; Zhu, Xiao-Dong; Tang, Xian-Zhong; Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei
2015-01-01
In this study, we performed a network meta-analysis to compare the outcomes of seven most common surgical procedures to fix DRF, including bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating. Published studies were retrieved through PubMed, Embase and Cochrane Library databases. The database search terms used were the following keywords and MeSH terms: DRF, bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating. The network meta-analysis was performed to rank the probabilities of postoperative complication risks for the seven surgical modalities in DRF patients. This network meta-analysis included data obtained from a total of 19 RCTs. Our results revealed that compared to DRF patients treated with bridging external fixation, marked differences in pin-track infection (PTI) rate were found in patients treated with plaster fixation, volar plating, and dorsal and volar plating. Cluster analysis showed that plaster fixation is associated with the lowest probability of postoperative complication in DRF patients. Plaster fixation is associated with the lowest risk for postoperative complications in DRF patients, when compared to six other common DRF surgical methods examined. PMID:26549312
Bilateral external ear canal osteomas - discussion on a clinical case.
Gheorghe, D C; Stanciu, A E; Ulici, A; Zamfir-Chiru-Anton, A
2016-01-01
Osteomas of the external ear are uncommon benign tumors that need to be differentiated from the external ear canal exostoses, bony proliferations that are linked mainly to cold-water exposure. Clinical manifestations vary from no symptoms to recurrent local infections and external ear cholesteatoma. Objective: presenting a rare case that we did not find described in the published literature. A patient with multiple long-term asymptomatic osteomas of both external ear canals presented to our department. Material: Data recorded from the patient's medical record was reviewed and analyzed. Surgery was performed and histology confirmed the presumptive diagnosis. Results: There was a discrepancy between the local severity of the disease, with a complete obstruction of his ear canals, and the long-term disease-free status of the patient. Conclusion: We hypothesized about the etiology of these multiple bilateral osteomas of the EAC, in light of the clinical and surgical findings.
Zhang, Haiying; Jiao, Ling; Cui, Songye; Wang, Liang; Tan, Jian; Zhang, Guizhi; He, Yajing; Ruan, Shuzhou; Fan, Saijun; Zhang, Wenyi
2014-01-01
Radiation safety is an integral part of targeted radionuclide therapy. The aim of this work was to study the external dose rate and retained body activity as functions of time in differentiated thyroid carcinoma patients receiving 131I therapy. Seventy patients were stratified into two groups: the ablation group (A) and the follow-up group (FU). The patients’ external dose rate was measured, and simultaneously, their retained body radiation activity was monitored at various time points. The equations of the external dose rate and the retained body activity, described as a function of hours post administration, were fitted. Additionally, the release time for patients was calculated. The reduction in activity in the group receiving a second or subsequent treatment was more rapid than the group receiving only the initial treatment. Most important, an expeditious method was established to indirectly evaluate the retained body activity of patients by measuring the external dose rate with a portable radiation survey meter. By this method, the calculated external dose rate limits are 19.2, 8.85, 5.08 and 2.32 μSv·h−1 at 1, 1.5, 2 and 3 m, respectively, according to a patient’s released threshold level of retained body activity <400 MBq. This study is beneficial for radiation safety decision-making. PMID:25337944
Pain during external dacryocystorhinostomy with local anesthesia.
Knežević, Miroslav M; Stojković, Milenko Ž; Vlajković, Gordana P; Jovanović, Miloš B; Rašić, Dejan M
2011-06-01
External dacryocystorhinostomy (DCR) is often performed under local anesthesia (LA) without adequate knowledge of the pain experienced by the patient. We subdivided our surgical technique into stages easily understood by the patients (introducing cotton tipped applicators, performing parabulbar injection, creating the incision, bone cracking (opening the ostium), manipulating the nose, intubating, closing the wound, and packing with gauze). A total of 50 patients ranging in age from 31 to 83 years of age (63.64±9.64) underwent external DCR. Each patient was asked 30 minutes after surgery to indicate the intensity of pain experienced at each stage of the surgery and during intramuscular (i.m.) injection of an antibiotic using a visual analog scale (VAS). Analysis of the VAS-based pain scores indicated 3 statistically equal occurrences of pain coinciding with the opening of the ostium, and receiving both parabulbar anesthetic and i.m. antibiotic injections. The level of pain experienced during the most unpleasant stage of external DCR (ostium opening) was similar to the pain experienced from an i.m. injection. Patients can be informed that pain during external DCR with local anesthesia is comparable to receiving an i.m. gluteal injection.
NASA Astrophysics Data System (ADS)
Suherman, A.; Rahman, M. Z. A.; Busu, I.
2014-02-01
The presence of hydrocarbon seepage is generally associated with rock or mineral alteration product exposures, and changes of soil properties which manifest with bare development and stress vegetation. This alters the surface thermodynamic properties, changes the energy balance related to the surface reflection, absorption and emission, and leads to shift in albedo and LST. Those phenomena may provide a guide for seepage detection which can be recognized inexpensively by remote sensing method. District of Miri is used for study area. Available topographic maps of Miri and LANDSAT ETM+ were used for boundary construction and determination albedo and LST. Three land use classification methods, namely fixed, supervised and NDVI base classifications were employed for this study. By the intensive land use classification and corresponding statistical comparison was found a clearly shift on albedo and land surface temperature between internal and external seepage potential area. The shift shows a regular pattern related to vegetation density or NDVI value. In the low vegetation density or low NDVI value, albedo of internal area turned to lower value than external area. Conversely in the high vegetation density or high NDVI value, albedo of internal area turned to higher value than external area. Land surface temperature of internal seepage potential was generally shifted to higher value than external area in all of land use classes. In dense vegetation area tend to shift the temperature more than poor vegetation area.
Computer designed compensation filters for use in radiation therapy. Master's thesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higgins, R. Jr.
1982-12-01
A computer program was written in the MUMPS language to design filters for use in cancer radiotherapy. The filter corrects for patient surface irregularities and allows homogeneous dose distribution with depth in the patient. The program does not correct for variations in the density of the patient. The program uses data available from the software in Computerized Medical Systems Inc.'s Radiation Treatment Planning package. External contours of General Electric CAT scans are made using the RTP software. The program uses the data from these external contours in designing the compensation filters. The program is written to process from 3 tomore » 31, 1cm thick, CAT scan slices. The output from the program can be in one of two different forms. The first option will drive the probe of a CMS Water Phantom in three dimensions as if it were the bit of a routing machine. Thus a routing machine constructed to run from the same output that drives the Water Phantom probe would produce a three dimensional filter mold. The second option is a listing of thicknesses for an array of aluminum blocks to filter the radiation. The size of the filter array is 10 in. by 10 in. The Printronix printer provides an array of blocks 1/2 in. by 1/2 in. with the thickness in millimeters printed inside each block.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, David W., E-mail: David.Chang@petermac.org; Marvelde, Luc te; Chua, Boon H.
Purpose: To report the local recurrence rate and late toxicity of intraoperative radiation therapy (IORT) boost to the tumor bed using the Intrabeam System followed by external-beam whole-breast irradiation (WBI) in women with early-stage breast cancer in a prospective single-institution study. Methods and Materials: Women with breast cancer ≤3 cm were recruited between February 2003 and May 2005. After breast-conserving surgery, a single dose of 5 Gy IORT boost was delivered using 50-kV x-rays to a depth of 10 mm from the applicator surface. This was followed by WBI to a total dose of 50 Gy in 25 fractions. Patientsmore » were reviewed at regular, predefined intervals. Late toxicities were recorded using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring systems. Results: Fifty-five patients completed both IORT boost and external-beam WBI. Median follow-up was 3.3 years (range, 1.4-4.1 years). There was no reported locoregional recurrence or death. One patient developed distant metastases. Grade 2 and 3 subcutaneous fibrosis was detected in 29 (53%) and 8 patients (15%), respectively. Conclusions: The use of IORT as a tumor bed boost using kV x-rays in breast-conserving therapy was associated with good local control but a clinically significant rate of grade 2 and 3 subcutaneous fibrosis.« less
NASA Astrophysics Data System (ADS)
Zhang, Z. T.; Sohn, I. R.; Pettit, F. S.; Meier, G. H.; Sridhar, S.
2009-08-01
The present study is an investigation of the surface and subsurface oxidation of Mn solid-solution-strengthened interstitial-free (IF) steels with the objective of elucidating the surface evolution before coating. Thermogravimetric (TG) analysis was carried out under 95 vol pct Ar + 5 vol pct (H2 + H2O) atmospheres with P_{{{text{H}}2 {text{O}}}} /P_{{{text{H}}2 }} ranging from 0.01 to 0.13 and temperatures ranging from 800 °C to 843 °C. Post-exposure characterization was carried out through scanning electron microscopy (SEM)/energy-dispersive spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and glancing-angle X-ray diffraction (XRD) to study the external and internal oxide evolution. The oxidation proceeds as a combination of the internal and external formation of Mn oxides. Decreasing the P_{{{text{H}}2 {text{O}}}} /P_{{{text{H}}2 }} ratios or temperature has the effect of decreasing the amount of oxidation, which is a combination of internal and external oxidation controlled by solid-state oxygen and manganese diffusion, respectively. External oxides are not continuous; they are instead concentrated near the intersection of alloy grain boundaries with the external surface. Internal oxides are concentrated along the grain boundaries. The effects of Sb (0.03 wt pct), B (10 ppm), P (0.04 and 0.08 wt pct), and Si (0.06 to 1.5 wt pct) on the oxidation were investigated. It is found that small amounts of Sb and B have a significant effect on decreasing both the external and internal oxidation, whereas Si and P increase the external and internal oxidation.
Turbine vane with high temperature capable skins
Morrison, Jay A [Oviedo, FL
2012-07-10
A turbine vane assembly includes an airfoil extending between an inner shroud and an outer shroud. The airfoil can include a substructure having an outer peripheral surface. At least a portion of the outer peripheral surface is covered by an external skin. The external skin can be made of a high temperature capable material, such as oxide dispersion strengthened alloys, intermetallic alloys, ceramic matrix composites or refractory alloys. The external skin can be formed, and the airfoil can be subsequently bi-cast around or onto the skin. The skin and the substructure can be attached by a plurality of attachment members extending between the skin and the substructure. The skin can be spaced from the outer peripheral surface of the substructure such that a cavity is formed therebetween. Coolant can be supplied to the cavity. Skins can also be applied to the gas path faces of the inner and outer shrouds.
Surface effects on friction-induced fluid heating in nanochannel flows.
Li, Zhigang
2009-02-01
We investigate the mechanism of friction-induced fluid heating under the influence of surfaces. The temperature distributions of liquid argon and helium in nanoscale Poiseuille flows are studied through molecular dynamics simulations. It is found that the fluid heating is mainly caused by the viscous friction in the fluid when the external force is small and there is no slip at the fluid-solid interface. When the external force is larger than the fluid-surface binding force, the friction at the fluid-solid interface dominates over the internal friction of the fluid and is the major contribution to fluid heating. An asymmetric temperature gradient in the fluid is developed in the case of nonidentical walls and the general temperature gradient may change sign as the dominant heating factor changes from internal to interfacial friction with increasing external force. The effect of temperature on the fluid heating is also discussed.
Engineering Topological Surface State of Cr-doped Bi2Se3 under external electric field
NASA Astrophysics Data System (ADS)
Zhang, Jian-Min; Lian, Ruqian; Yang, Yanmin; Xu, Guigui; Zhong, Kehua; Huang, Zhigao
2017-03-01
External electric field control of topological surface states (SSs) is significant for the next generation of condensed matter research and topological quantum devices. Here, we present a first-principles study of the SSs in the magnetic topological insulator (MTI) Cr-doped Bi2Se3 under external electric field. The charge transfer, electric potential, band structure and magnetism of the pure and Cr doped Bi2Se3 film have been investigated. It is found that the competition between charge transfer and spin-orbit coupling (SOC) will lead to an electrically tunable band gap in Bi2Se3 film under external electric field. As Cr atom doped, the charge transfer of Bi2Se3 film under external electric field obviously decreases. Remarkably, the band gap of Cr doped Bi2Se3 film can be greatly engineered by the external electric field due to its special band structure. Furthermore, magnetic coupling of Cr-doped Bi2Se3 could be even mediated via the control of electric field. It is demonstrated that external electric field plays an important role on the electronic and magnetic properties of Cr-doped Bi2Se3 film. Our results may promote the development of electronic and spintronic applications of magnetic topological insulator.
Numerical study of aerodynamic effects on road vehicles lifting surfaces
NASA Astrophysics Data System (ADS)
Cernat, Mihail Victor; Cernat Bobonea, Andreea
2017-01-01
The aerodynamic performance analysis of road vehicles depends on the study of engine intake and cooling flow, internal ventilation, tire cooling, and overall external flow as the motion of air around a moving vehicle affects all of its components in one form or another. Due to the complex geometry of these, the aerodynamic interaction between the various body components is significant, resulting in vortex flow and lifting surface shapes. The present study, however focuses on the effects of external aerodynamics only, and in particular on the flow over the lifting surfaces of a common compact car, designed especially for this study.
NASA Astrophysics Data System (ADS)
Veres, C.; Garsi, J. P.; Rubino, C.; Pouzoulet, F.; Bidault, F.; Chavaudra, J.; Bridier, A.; Ricard, M.; Ferreira, I.; Lefkopoulos, D.; de Vathaire, F.; Diallo, I.
2010-11-01
The aim of this study is to define criteria for accurate representation of the thyroid in human models used to represent external beam radiotherapy (EBRT) patients and evaluate the relationship between the volume of this organ and clinical and anthropometric characteristics. From CT images, we segmented the thyroid gland and calculated its volume for a population of 188 EBRT patients of both sexes, with ages ranging from 1 to 89 years. To evaluate uncertainties linked to measured volumes, experimental studies on the Livermore anthropomorphic phantom were performed. For our population of EBRT patients, we observed that in children, thyroid volume increased rapidly with age, from about 3 cm3 at 2 years to about 16 cm3 at 20. In adults, the mean thyroid gland volume was 23.5 ± 9 cm3 for males and 17.5 ± 8 cm3 for females. According to anthropometric parameters, the best fit for children was obtained by modeling the log of thyroid volume as a linear function of body surface area (BSA) (p < 0.0001) and age (p = 0.04) and for adults, as a linear function of BSA (p < 0.0001) and gender (p = 0.01). This work enabled us to demonstrate that BSA was the best indicator of thyroid volume for both males and females. These results should be taken into account when modeling the volume of the thyroid in human models used to represent EBRT patients for dosimetry in retrospective studies of the relationship between the estimated dose to the thyroid and long-term follow-up data on EBRT patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Regmi, Rajesh; Lovelock, D. Michael; Zhang, Pengpeng
Purpose: To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate. Methods: Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min. Each patient had at least one implanted fiducial marker near the tumor. In all scans, abdominal displacement (Varian RPM) was recorded as the external motion signal. Purpose-built software tracked fiducials, representing internal signal, in CBCT projection images. Time lag between superior–inferior (SI) internal and anterior–posterior externalmore » signals was found by maximizing the correlation coefficient in each breathing cycle and averaging over all cycles. Time-lag-induced discrepancy between internal SI position and that predicted from the external signal (external prediction error) was also calculated. Results: Mean ± standard deviation time lag, over all scans and patients, was 0.10 ± 0.07 s (range 0.01–0.36 s). External signal lagged the internal in 17/18 scans. Change in time lag between pre- and post-treatment CBCT was 0.06 ± 0.07 s (range 0.01–0.22 s), corresponding to 3.1% ± 3.7% (range 0.6%–10.8%) of gate width (range 1.6–3.1 s). In only one patient, change in time lag exceeded 10% of the gate width. External prediction error over all scans of all patients varied from 0.1 ± 0.1 to 1.6 ± 0.4 mm. Conclusions: Time lag between internal motion along SI and external signals is small compared to the treatment gate width of abdominal patients examined in this study. Change in time lag within a treatment session, inferred from pre- to post-treatment measurements is also small, suggesting that a single measurement of time lag at the session start is adequate. These findings require confirmation in a larger number of patients.« less
Malignant external otitis: early scintigraphic detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strashun, A.M.; Nejatheim, M.; Goldsmith, S.J.
1984-02-01
Pseudomonas otitis externa in elderly diabetics may extend aggressively to adjacent bone, cranial nerves, meninges, and vessels, leading to a clinical diagnosis of ''malignant'' external otitis. Early diagnosis is necessary for successful treatment. This study compares the findings of initial radiographs, thin-section tomography of temporal bone, CT scans of head and neck, technetium-99m methylene diphosphonate (MDP) and gallium-67 citrate scintigraphy, and single-photon emission computed tomography (SPECT) for detection of temporal bone osteomylitis in ten patients fulfilling the clinical diagnostic criteria of malignant external otitis. Skull radiographs were negative in all of the eight patients studied. Thin-section tomography was positive inmore » one of the seven patients studied using this modality. CT scanning suggested osteomyelitis in three of nine patients. Both Tc-99m and Ga-67 citrate scintigraphy were positive in 10 of 10 patients. These results suggest that technetium and gallium scintigraphy are more sensitive than radiographs and CT scans for early detection of malignant external otitis.« less
NASA Astrophysics Data System (ADS)
Sekine, Katsuhisa
2017-12-01
In order to represent the effects of T-tubules and folded surface membranes on the electrical admittance and impedance of skeletal muscles measured by the external-electrode method, analytical relations for the equivalent complex conductivities of hypothetical smooth surface membranes were derived. In the relations, the effects of each tubule were represented by the admittance of a straight cable. The effects of the folding of a surface membrane were represented by the increased area of surface membranes. The equivalent complex conductivities were represented as summation of these effects, and the effects of the T-tubules were different between the transversal and longitudinal directions. The validity of the equivalent complex conductivities was supported by the results of finite-difference method (FDM) calculations made using three-dimensional models in which T-tubules and folded surface membranes were represented explicitly. FDM calculations using the equivalent complex conductivities suggested that the electrically inhomogeneous structure due to the existence of muscle cells with T-tubules was sufficient for explaining the experimental results previously obtained using the external-electrode method. Results of FDM calculations in which the structural changes caused by muscle contractions were taken into account were consistent with the reported experimental results.
Silica powders for powder evacuated thermal insulating panel and method
Harris, Michael T.; Basaran, Osman A.; Kollie, Thomas G.; Weaver, Fred J.
1996-01-01
A powder evacuated thermal insulating panel using generally spherical and porous silica particles of a median size less than about 100 nanometers in diameter, a pour packing density of about 0.4 to 0.6 g/cm.sup.3 and an external surface area in the range of about 90 to 600 m.sup.2/ g is described. The silica powders are prepared by reacting a tetraakyl silicate with ammonia and water in an alcohol solvent, distilling the solution after the reaction to remove the ammonia and recover the alcohol. The resulting aqueous slurry was dried, ball-milled, and dried again to provide the silica particles with defined internal and external porosity. The nanometer size and the large external surface area of the silica particles along with the internal and external porosity of the silica particles provide powder evacuated thermal insulating panels with significantly higher R-values than obtainable using previously known silica powders.
Silica powders for powder evacuated thermal insulating panel and method
Harris, Michael T.; Basaran, Osman A.; Kollie, Thomas G.; Weaver, Fred J.
1994-01-01
A powder evacuated thermal insulating panel using generally spherical and porous silica particles of a median size less than about 100 nanometers in diameter, a pour packing density of about 0.4 to 0.6 g/cm.sup.3 and an external surface area in the range of about 90 to 600 m.sup.2 /g is described. The silica powders are prepared by reacting a tetraakyl silicate with ammonia and water in an alcohol solvent, distilling the solution after the reaction to remove the ammonia and recover the alcohol. The resulting aqueous slurry was dried, ball-milled, and dried again to provide the silica particles with defined internal and external porosity. The nanometer size and the large external surface area of the silica particles along with the internal and external porosity of the silica particles provide powder evacuated thermal insulating panels with significantly higher R-values than obtainable using previously known silica powders.
Silica powders for powder evacuated thermal insulating panel and method
Harris, Michael T.; Basaran, Osman A.; Kollie, Thomas G.; Weaver, Fred J.
1995-01-01
A powder evacuated thermal insulating panel using generally spherical and porous silica particles of a median size less than about 100 nanometers in diameter, a pour packing density of about 0.4 to 0.6 g/cm.sup.3 and an external surface area in the range of about 90 to 600 m.sup.2/ g is described. The silica powders are prepared by reacting a tetraakyl silicate with ammonia and water in an alcohol solvent, distilling the solution after the reaction to remove the ammonia and recover the alcohol. The resulting aqueous slurry was dried, ball-milled, and dried again to provide the silica particles with defined internal and external porosity. The nanometer size and the large external surface area of the silica particles along with the internal and external porosity of the silica particles provide powder evacuated thermal insulating panels with significantly higher R-values than obtainable using previously known silica powders.
Silica powders for powder evacuated thermal insulating panel and method
Harris, M.T.; Basaran, O.A.; Kollie, T.G.; Weaver, F.J.
1996-01-02
A powder evacuated thermal insulating panel using generally spherical and porous silica particles of a median size less than about 100 nanometers in diameter, a pour packing density of about 0.4 to 0.6 g/cm{sup 3} and an external surface area in the range of about 90 to 600 m{sup 2}/g is described. The silica powders are prepared by reacting a tetraalkyl silicate with ammonia and water in an alcohol solvent, distilling the solution after the reaction to remove the ammonia and recover the alcohol. The resulting aqueous slurry was dried, ball-milled, and dried again to provide the silica particles with defined internal and external porosity. The nanometer size and the large external surface area of the silica particles along with the internal and external porosity of the silica particles provide powder evacuated thermal insulating panels with significantly higher R-values than obtainable using previously known silica powders. 2 figs.
Knudsen, Mads Faurschou; Jacobsen, Bo Holm; Seidenkrantz, Marit-Solveig; Olsen, Jesper
2014-01-01
The Atlantic Multidecadal Oscillation (AMO) represents a significant driver of Northern Hemisphere climate, but the forcing mechanisms pacing the AMO remain poorly understood. Here we use the available proxy records to investigate the influence of solar and volcanic forcing on the AMO over the last ~450 years. The evidence suggests that external forcing played a dominant role in pacing the AMO after termination of the Little Ice Age (LIA; ca. 1400–1800), with an instantaneous impact on mid-latitude sea-surface temperatures that spread across the North Atlantic over the ensuing ~5 years. In contrast, the role of external forcing was more ambiguous during the LIA. Our study further suggests that the Atlantic Meridional Overturning Circulation is important for linking external forcing with North Atlantic sea-surface temperatures, a conjecture that reconciles two opposing theories concerning the origin of the AMO. PMID:24567051
Knudsen, Mads Faurschou; Jacobsen, Bo Holm; Seidenkrantz, Marit-Solveig; Olsen, Jesper
2014-02-25
The Atlantic Multidecadal Oscillation (AMO) represents a significant driver of Northern Hemisphere climate, but the forcing mechanisms pacing the AMO remain poorly understood. Here we use the available proxy records to investigate the influence of solar and volcanic forcing on the AMO over the last ~450 years. The evidence suggests that external forcing played a dominant role in pacing the AMO after termination of the Little Ice Age (LIA; ca. 1400-1800), with an instantaneous impact on mid-latitude sea-surface temperatures that spread across the North Atlantic over the ensuing ~5 years. In contrast, the role of external forcing was more ambiguous during the LIA. Our study further suggests that the Atlantic Meridional Overturning Circulation is important for linking external forcing with North Atlantic sea-surface temperatures, a conjecture that reconciles two opposing theories concerning the origin of the AMO.
A generalized force-modified potential energy surface (G-FMPES) for mechanochemical simulations
Subramanian, Gopinath; Mathew, Nithin; Leiding, Jeffery A.
2015-10-05
We describe the modifications that a spatially varying external load produces on a Born-Oppenheimer potential energy surface (PES) by calculating static quantities of interest. The effects of the external loads are exemplified using electronic structure calculations (at the HF/6-31G** level) of two different molecules: ethane and hexahydro-1,3,5-trinitro-s-triazine (RDX). The calculated transition states and The Hessian matrices of stationary points show that spatially varying external loads shift the stationary points and modify the curvature of the PES, thereby affecting the harmonic transition rates by altering both the energy barrier as well as the prefactor. The harmonic spectra of both molecules aremore » blue-shifted with increasing compressive “pressure.” Some stationary points on the RDX-PES disappear under application of the external load, indicating the merging of an energy minimum with a saddle point.« less
Battisti, Nicolò Matteo Luca; Sehovic, Marina; Extermann, Martine
2017-09-01
Non-small-cell lung cancer (NSCLC) is a disease of the elderly, who are under-represented in clinical trials. This challenges the external validity of the evidence base for its management and of current guidelines, that we evaluated in a population of older patients. We retrieved randomized clinical trials (RCTs) supporting the guidelines and identified 18 relevant topics. We matched a cohort of NSCLC patients aged older than 80 years from the Moffitt Cancer Center database with the studies' eligibility criteria to check their qualification for at least 2 studies. Eligibility > 60% was rated full validity, 30% to 60% partial validity, and < 30% limited validity. We obtained data from 760 elderly patients in stage-adjusted groups and collected 244 RCTs from the National Comprehensive Cancer Network (NCCN) and 148 from the European Society for Medical Oncology (ESMO) guidelines. External validity was deemed insufficient for neoadjuvant chemotherapy in stage III disease (27.37% and 25.26% of patients eligible for NCCN and ESMO guidelines, respectively) and use of bevacizumab (13.86% and 16.27% of patients eligible). For ESMO guidelines, it was inadequate regarding double-agent chemotherapy (25.90% of patients eligible), its duration (24.10%) and therapy for Eastern Cooperative Oncology Group performance status 2 patients (17.74%). For NCCN guidelines external validity was lacking for neoadjuvant chemoradiotherapy in stage IIIA disease (25.86% of patients eligible). Our analysis highlighted the effect of RCT eligibility criteria on guidelines' external validity in elderly patients. Eligibility criteria should be carefully considered in trial design and more studies that do not exclude elderly patients should be included in guidelines. Copyright © 2017 Elsevier Inc. All rights reserved.
Cerebral network deficits in post-acute catatonic schizophrenic patients measured by fMRI.
Scheuerecker, J; Ufer, S; Käpernick, M; Wiesmann, M; Brückmann, H; Kraft, E; Seifert, D; Koutsouleris, N; Möller, H J; Meisenzahl, E M
2009-03-01
Twelve patients with catatonic schizophrenia and 12 matched healthy controls were examined with functional MRI while performing a motor task. The aim of our study was to identify the intracerebral pathophysiological correlates of motor symptoms in catatonic patients. The motor task included three conditions: a self-initiated (SI), an externally triggered (ET) and a rest condition. Statistical analysis was performed with SPM5. During the self-initiated movements patients showed significantly less activation than healthy controls in the supplementary motor area (SMA), the prefrontal and parietal cortex. Our results suggest a dysfunction of the "medial motor system" in catatonic patients. Self-initiated and externally triggered movements are mediated by different motor loops. The "medial loop" includes the SMA, thalamus and basal ganglia, and is necessary for self-initiated movements. The "lateral loop" includes parts of the cerebellum, lateral premotor cortex, thalamus and parietal association areas. It is involved in the execution of externally triggered movements. Our findings are in agreement with earlier behavioral data, which show deficits in self-initiated movements in catatonic patients but no impairment of externally triggered movements.
Norlund, Sofia; Fjellman-Wiklund, Anncristine; Nordin, Maria; Stenlund, Therese; Ahlgren, Christina
2013-06-01
The aim of the study was to explore experiences and thoughts in the process of returning to work in employed patients with Exhaustion Disorder. Twelve patients with Exhaustion Disorder (burnout) who had been referred to a Stress Rehabilitation Clinic were interviewed. All patients were employed but a majority was on full or part-time sick leave. Grounded Theory was used as the qualitative method. A core category, regaining the ability to work, was developed. Alongside, two categories, internal resources and the external support system, were experienced as being important to the process. The internal resources were expressed through three key features (sub-categories), perceived validation, insights and adaptive coping abilities. The external support system was diverse and described by the sub-categories practical/structural and/or emotional support. Four external support actors were identified; the workplace, health care, the Social Insurance Agency, and the union. The supervisor was described as the most important external actor. Internal and external resources are intertwined in the process of regaining the ability to work. The internal resources and external support can directly increase the probability to regain the ability to work. Moreover, these resources can affect each other and thus indirectly have an effect on the process.
Schortgen, F
2012-11-01
Fever is a common symptom of sepsis usually believed to predict better survival. Experimental data suggest that body temperature elevation may slow micro-organism growth and enhance host immune responses. In patients with sepsis, however, the high energy cost of fever may exacerbate the life-threatening situation. Fever control is widely used in the ICU, mainly in patients with infections. The efficacy of antipyretic drugs in lowering body temperature remains uncertain, however, and all antipyretics have well known adverse effects. Surface cooling methods are efficient but require sedation to avoid the harmful effects of shivering. A recent controlled trial in patients with septic shock suggests that external cooling for fever control may diminish vasopressor requirements and improve early survival. In this review, we examine the benefits and risks of fever and of controlled normothermia. The fever control modalities that provide the best risk/benefit ratio in sepsis are discussed.
Radiation therapy of primary vaginal carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nori, D.; Hilaris, B.S.; Stanimir, G.
1983-10-01
Primary carcinoma of the vagina is rare, constituting only 1 to 2% of all neoplasms arising in the female genital tract. From 1950-1974, 36 patients with carcinoma of the vagina were treated with radiation at Memorial Sloan-Kettering Cancer Center (MSKCC); 35 (96%) had epidermoid carcinoma and one patient (4%) had adenocarcinoma. These patients were staged according to FIGO. Fourteen patients (39%) were Stage I; six patients (17%) were Stage II; three patients (8%) were Stage III; and 13 patients (36%) were Stage IV. Nine patients (25%) were treated with external radiation and interstitial implant; seven patients (20%) were treated withmore » interstitial implant alone; nine patients (25%) were treated with external radiation alone and 11 patients (30%) with external radiation and intracavitary radiation. The five year NED survival was 71% in Stage I, 66% in Stage II, 33% in Stage III and 0% in Stage IV. This paper discusses radiotherapy management of primary carcinoma of the vagina.« less
Extermophylic microorganisms: issue of interplanetary transfer on external spacecraft surfaces.
NASA Astrophysics Data System (ADS)
Novikova, N.; Deshevaya, E.; Polykarpov, N.; Svistunova, Y.; Grigoriev, A.
Interplanetary transfer of terrestrial microbes capable of surviving in extreme environments and planetary protection from accidental biocontamination by them are the issues of major practical rather than hypothetical value The natural resistance of microbes to extreme environments and a possibility of their transfer beyond geographical barriers of Earth on external spacecraft surfaces have brought forward a need in profound research into the likelihood of their survival in outer space Hardware and a program have been developed at the State Scientific Research Center of the Russian Federation -- Institute for Biomedical Problems with the goal of carrying out a space experiment Biorisk The experiment was aimed at assessing the possibility of long-term comparable with the duration of the Martian flight survival of microorganisms in outer space on materials used in space industry Samples of materials were contaminated with test cultures of bacteria Bacillus and fungi Aspergillus Penicillium Cladosporium known to be common residents of various environments on Earth and resistant to multiple alternation of high and low temperatures Materials used in the construction of external spacecraft surfaces such as steel aluminium alloy heat-insulating coating were chosen as test samples for the experiment Containers with materials and test microorganisms were placed on the external side of the Russian segment of the ISS Unique data have been accumulated after a 204 day exposure on the external side of the ISS which have proved that
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nasehi Tehrani, J; Wang, J; McEwan, A
Purpose: In this study, we developed and evaluated a method for predicting lung surface deformation vector fields (SDVFs) based on surrogate signals such as chest and abdomen motion at selected locations and spirometry measurements. Methods: A Patient-specific 3D triangular surface mesh of the lung region at end-expiration (EE) phase was obtained by threshold-based segmentation method. For each patient, a spirometer recorded the flow volume changes of the lungs; and 192 selected points at a regular spacing of 2cm X 2cm matrix points over a total area of 34cm X 24cm on the surface of chest and abdomen was used tomore » detect chest wall motions. Preprocessing techniques such as QR factorization with column pivoting (QRCP) were employed to remove redundant observations of the chest and abdominal area. To create a statistical model between the lung surface and the corresponding surrogate signals, we developed a predictive model based on canonical ridge regression (CRR). Two unique weighting vectors were selected for each vertex on the surface of the lung, and they were optimized during the training process using the all other phases of 4D-CT except the end-inspiration (EI) phase. These parameters were employed to predict the vertices locations of a testing data set, which was the EI phase of 4D-CT. Results: For ten lung cancer patients, the deformation vector field of each vertex of lung surface mesh was estimated from the external motion at selected positions on the chest wall surface plus spirometry measurements. The average estimation of 98th percentile of error was less than 1 mm (AP= 0.85, RL= 0.61, and SI= 0.82). Conclusion: The developed predictive model provides a non-invasive approach to derive lung boundary condition. Together with personalized biomechanical respiration modelling, the proposed model can be used to derive the lung tumor motion during radiation therapy accurately from non-invasive measurements.« less
Gonzalez-Ceron, L; Rodriguez, M H; Santillan, F; Chavez, B; Nettel, J A; Hernandez-Avila, J E; Kain, K C
2001-07-01
Anopheles albimanus and An. pseudopunctipennis differ in their susceptibilities to Plasmodium vivax circumsporozoite phenotypes. An. pseudopunctipennis is susceptible to phenotype VK247 but almost refractory to VK210. In contrast, An. albimanus is almost refractory to VK247 but susceptible to VK210. To investigate the site in the mosquito and the parasite stage at which resistance mechanisms affect VK247 development in An. albimanus, parasite development was followed in a series of experiments in which both mosquitoes species were simultaneously infected with blood from patients. Parasite phenotype was determined in mature oocysts and salivary gland sporozoites by use of immunofluorescence and Western blot assays and/or gene identification. Ookinete maturation and their densities within the bloodmeal bolus were similar in both mosquito species. Ookinete densities on the internal midgut surface of An. albimanus were 4.7 times higher than those in An. pseudopunctipennis; however, the densities of developing oocysts on the external midgut surface were 6.12 times higher in the latter species. Electron microscopy observation of ookinetes in An. albimanus midgut epithelium indicated severe parasite damage. These results indicate that P. vivax VK247 parasites are destroyed at different parasite stages during migration in An. albimanus midguts. A portion, accumulated on the internal midgut surface, is probably destroyed by the mosquito's digestive enzymes and another portion is most likely destroyed by mosquito defense molecules within the midgut epithelium. A third group, reaching the external midgut surface, initiates oocyst development, but over 90% of them interrupt their development and die. The identification of mechanisms that participate in parasite destruction could provide new elements to construct transgenic mosquitoes resistant to malaria parasites. Copyright 2001 Academic Press.
Lu, W; Zhu, X C; Zhang, X Y; Chen, Y T; Chen, W H
2016-09-20
Objective: To determine the relative protection provided by N95 filtering facepiece respirators (FFR) and disposable medicine masks (DMM) against airborne bacteria in different working environments. Methods: The field study was performed with 12 subjects wearing an N95 filtering facepiece respirator and a disposable medicine mask for 1h, respectively. Airborne microorganisms and bacteria samples from both the external (Ce) and the inner (Ci) surface of N95 FFR and DMM are collected. The Ce: Ci ratio was used to calculate the bacterial filtering proportion. Bacterial filtering efficiency (BFE) was measured using the JWL-2A Sampler. Results: The bacterial filtration efficiency of N95 FFR and DMM were 99.93% and 91.53%, respectively. There was significant difference between the two materials ( P <0.05). In summer, airborne bacterial concentration was higher than that in winter. In the same season, airborne bacterial concentration in hospital environment is higher than that in campus. The higher the airborne bacterial concentration, the greater bacterial contaminated on the external surface of the used masks. To all masks used in different working environment, bacterial contamination on the external surface was much greater than the inner surface ( P <0.01). Compared to N95 FFR, DMM had slighter bacterial contamination on the external surface and greater bacterial contamination on the inner surface. However, this difference was not significant ( P >0.05). The bacterial filtering proportion of N95 FFR is higher than DMM. These differences were significant in samples tested in summer ( P <0.05) , but were not significant in samples tested in winter ( P >0.05). Conclusion: Bacterial filtering efficiency of N95 respirator is superior to medicine mask, and this advantage become more obvious in high airborne bacterial concentration levels.
Jeon, Byoungseon; Van Overmeere, Quentin; van Duin, Adri C T; Ramanathan, Shriram
2013-02-14
Oxidation of iron surfaces and oxide growth mechanisms have been studied using reactive molecular dynamics. Oxide growth kinetics on Fe(100), (110), and (111) surface orientations has been investigated at various temperatures and/or an external electric field. The oxide growth kinetics decreases in the order of (110), (111), and (100) surfaces at 300 K over 1 ns timescale while higher temperature increases the oxidation rate. The oxidation rate shows a transition after an initial high rate, implying that the oxide formation mechanism evolves, with iron cation re-ordering. In early stages of surface oxide growth, oxygen transport through iron interstitial sites is dominant, yielding non-stoichiometric wüstite characteristics. The dominant oxygen inward transport decreases as the oxide thickens, evolving into more stoichiometric oxide phases such as wüstite or hematite. This also suggests that cation outward transport increases correspondingly. In addition to oxidation kinetics simulations, formed oxide layers have been relaxed in the range of 600-1500 K to investigate diffusion characteristics, fitting these results into an Arrhenius relation. The activation energy of oxygen diffusion in oxide layers formed on Fe(100), (110), and (111) surfaces was estimated to be 0.32, 0.26, and 0.28 eV, respectively. Comparison between our modeling results and literature data is then discussed. An external electric field (10 MV cm(-1)) facilitates initial oxidation kinetics by promoting oxygen transport through iron lattice interstitial sites, but reaches self-limiting thickness, showing that similar oxide formation stages are maintained when cation transport increases. The effect of the external electric field on iron oxide structure, composition, and oxide activation energy is found to be minimal, whereas cation outward migration is slightly promoted.
Condensation Heat-Transfer Measurements of Refrigerants on Externally Enhanced Tubes.
1987-06-01
Pf Density of condensate at Tf (kgjm3 ) e Insulated angle em Rotation angle of normal to fin surface Of Surface tension of condensate (N/m) a Nusselt ...reported data for the condensation of steam at near atmospheric pressure on smooth tubes and roped tubes with and without a helical , external wrap of...Their model, a Nusselt -type equation based on the equivalent diameter of the finned tube, lives the average condensing coefficient by the following
TQUID Magnetometer and Artificial Neural Circuitry Based on a Topological Kondo Insulator
2016-05-01
phenomena in this surface-bulk system. Sufficient Joule heating , induced by an external DC current, can heat the bulk into a less insulating state, and...are the surface and bulk resistances with insulating gap Δ; H = H0(/0)3 and are the heat capacity dominated by phonons and...0, while Δ is the energy gap in the insulating bulk; is the temperature independent heat transfer rate trough external leads, which plays the
Ballistic Impact Resistance of Multi-Layer Textile Fabrics
1981-10-01
REBOT (NNOLA, NVAR). the first array contains the vector of forces externally applied to the ’ top surface of the layer under consideration, while the...array REBOT (NNOLA, NVAR) contains the forces externally applied to the lower surface of the array. Initially all the elements of each of the two arrays...Qodes in a layer, the contents of array REBOT are now replaced with those of array RETOP in preparation for the repetition of the same calculations for
Quantitative analysis of ice films by near-infrared spectroscopy
NASA Technical Reports Server (NTRS)
Keiser, Joseph T.
1990-01-01
One of the outstanding problems in the Space Transportation System is the possibility of the ice buildup on the external fuel tank surface while it is mounted on the launch pad. During the T-2 hours (and holding) period, the frost/ice thickness on the external tank is monitored/measured. However, after the resumption of the countdown time, the tank surface can only be monitored remotely. Currently, remote sensing is done with a TV camera coupled to a thermal imaging device. This device is capable of identifying the presence of ice, especially if it is covered with a layer of frost. However, it has difficulty identifying transparent ice, and, it is not capable of determining the thickness of ice in any case. Thus, there is a need for developing a technique for measuring the thickness of frost/ice on the tank surface during this two hour period before launch. The external tank surface is flooded with sunlight (natural or simulated) before launch. It may be possible, therefore, to analyze the diffuse reflection of sunlight from the external tank to determine the presence and thickness of ice. The purpose was to investigate the feasibility of this approach. A near-infrared spectrophotometer was used to record spectra of ice. It was determined that the optimum frequencies for monitoring the ice films were 1.03 and 1.255 microns.
Planform structure and heat transfer in turbulent free convection over horizontal surfaces
NASA Astrophysics Data System (ADS)
Theerthan, S. Ananda; Arakeri, Jaywant H.
2000-04-01
This paper deals with turbulent free convection in a horizontal fluid layer above a heated surface. Experiments have been carried out on a heated surface to obtain and analyze the planform structure and the heat transfer under different conditions. Water is the working fluid and the range of flux Rayleigh numbers (Ra) covered is 3×107-2×1010. The different conditions correspond to Rayleigh-Bénard convection, convection with either the top water surface open to atmosphere or covered with an insulating plate, and with an imposed external flow on the heated boundary. Without the external flow the planform is one of randomly oriented line plumes. At large Rayleigh number Ra and small aspect ratio (AR), these line plumes seem to align along the diagonal, presumably due to a large scale flow. The side views show inclined dyelines, again indicating a large scale flow. When the external flow is imposed, the line plumes clearly align in the direction of external flow. The nondimensional average plume spacing, Raλ1/3, varies between 40 and 90. The heat transfer rate, for all the experiments conducted, represented as RaδT-1/3, where δT is the conduction layer thickness, varies only between 0.1-0.2, showing that in turbulent convection the heat transfer rates are similar under the different conditions.
NASA Astrophysics Data System (ADS)
Berland, Kristian; Einstein, T. L.; Hyldgaard, Per
2012-02-01
To manipulate the Cu(111) partially-filled Shockley surface state, we study its response to an external fieldootnotetextKB, TLE, PH; arXiv 1109:6706 E and physisorbed PAHs and quinone molecules. We use density-functional theory calculations with periodic-boundary conditions. The van der Waals density functional version vdW-DF2 accounts for the molecular adsorption. The issue that the Kohn-Sham wave functions couple to both sides of the Cu slab is handled with a decoupling scheme based on a rotation in Hilbert space. A convergence study reveals that to obtain a proper Shockley surface state, 6 Cu layers is sufficient, while 15 is optimal. We use 6 layers for the response to the molecules and 15 to external field. We find that the surface state displays isotropic dispersion (up to order k^6), free-electron like until the Fermi wave vector but with a significant quartic component beyond. The shift in band minimum and effective mass depend linearly on E, with a smaller fractional change in the latter. Charge transfer occurs beyond the outermost copper atoms, and most of the screening is due to bulk electrons. We find that the molecular physisorption increases the band minimum, with the effect the of a quinone being much stronger than the corresponding PAH.
A new oviraptorid (Dinosauria: Theropoda) from the Upper Cretaceous of southern China.
Wang, Shuo; Sun, Chengkai; Sullivan, Corwin; Xu, Xing
2013-01-01
This paper describes a new oviraptorid dinosaur taxon, Ganzhousaurus nankangensis gen. et sp. nov., based on a specimen collected from the Upper Cretaceous Nanxiong Formation of Nankang County, Ganzhou City, Jiangxi Province, southern China. This new taxon is distinguishable from other oviraptorids based on the following unique combination of primitive and derived features: relatively shallow dentary; absence of fossa or pneumatopore on lateral surface of dentary; weakly downturned anterior mandibular end; shallow depression immediately surrounding anterior margin of external mandibular fenestra; external mandibular fenestra subdivided by anterior process of surangular; dentary posteroventral process slightly twisted and positioned on mandibular ventrolateral surface; shallow longitudinal groove along medial surface of dentary posteroventral process; angular anterior process wider transversely than deep dorsoventrally; sharp groove along ventrolateral surface of angular anterior process; ventral border of external mandibular fenestra formed mainly by angular; ventral flange along distal half of metatarsal II; and arctometatarsal condition absent. Phylogenetic analysis places Ganzhousaurus nankangensis gen. et sp. nov. in the clade Oviraptoridae, together with Oviraptor, Citipati, Rinchenia and the unnamed Zamyn Khondt oviraptorid.
Ippolito, Giorgio; Serrao, Mariano; Napoli, Francesco; Conte, Carmela; Miscusi, Massimo; Coppola, Gianluca; Pierelli, Francesco; Costanzo, Giuseppe; De Cupis, Vincenzo
2016-10-01
Latissimus dorsi tendon transfer (LDT) is a recent method for surgical treatment of massive, irreparable posterosuperior cuff tears (MIPCT). So far, there are no studies on the quantitative motion analysis of the shoulder and latissimus dorsi (LD) muscle activation after LDT. The changes in shoulder movements after LDT can be objectively assessed by the 3-D motion analysis. These changes may not be due to an increased activity of the LD muscle as external rotator. The shoulder kinematics of nine patients with MIPCT were recorded through a 3-D motion analysis system, before LTD (T0), and after 3 (T1) and 6 (T2) months post-LDT. Maximal shoulder flexion-extension, abduction-adduction, and horizontal abduction-adduction, and the internal and external circumduction of the shoulder joint were measured during upright standing posture. Surface EMG activity of the LD muscle was recorded during both internal rotation (IR) and external rotation (ER) tasks in three different postures. A significant increase of shoulder movements was observed at T2 compared with T0 for almost all motor tasks. A significant effect of LDT was also found on LD-IR/ER ratio in posture 1 at T2 compared with T0 and T1. No significant effects were found for the LD-IR/ER ratio in the other postures. Our study indicates that LDT is effective in shoulder motion recovery. Such improvement is not associated with a change in function of the LD muscle, which may be induced by a depression of the humeral head into the glenoid cavity instead.
Stress Fractures of Tibia Treated with Ilizarov External Fixator.
Górski, Radosław; Żarek, Sławomir; Modzelewski, Piotr; Górski, Ryszard; Małdyk, Paweł
2016-08-30
Stress fractures are the result of cyclic loading of the bone, which gradually becomes damaged. Most often they are treated by rest or plaster cast and, in rare cases, by internal fixation. There is little published data on initial reposition followed by stabilization with the Ilizarov apparatus in such fractures. Six patients were treated with an external fixator according to the Ilizarov method for a stress fracture of the tibia between 2007 and 2015. Three patients were initially treated conservatively. Due to increasing tibial deformation, they were qualified for surgical treatment with external stabilization. In the other patients, surgery was the first-line treatment. All patients demonstrated risk factors for a stress fracture. After the surgery, they fully loaded the operated limb. No patient developed malunion, nonunion, infection or venous thrombosis. The average time from the first operation to the removal of the external fixator was 19 weeks. Radiographic and clinical outcomes were satisfactory in all patients. 1. The Ilizarov method allows for successful stabilization of stress fractures of the tibia. 2. It may be a good alternative to internal stabilization, especially in patients with multiple comorbidities which affect bone quality and may impair soft tissue healing.
Treatment of unstable intraarticular fracture of distal radius: POP casting with external fixation.
ur Rahman, Obaid; Khan, Mohammad Qadeem; Rasheed, Haroon; Ahmad, Saleem
2012-04-01
To compare radiological and functional outcome of external fixation and distraction with conservative Plaster of Paris (POP) cast for unstable intra-articular fractures of the distal radius. The study was conducted on 60 patients with unstable intra-articular fracture of distal radius who reported to emergency or outpatient Orthopaedic Surgery department of Benazir Bhutto Hospital, Rawalpindi, between March and August 2007. They were divided into two equal groups: Group A and Group B, treated by Plaster of Paris cast, and external fixation with distraction respectively. The functional outcome in terms of freedom from pain, range of movement, grip power and deformity, and the radiological outcome of radial length, incongruity and radio-ulnar joint position were analysed at three months follow-up using a 3-point scoring scale. In Group A, 1 (3%) patient showed excellent result, 8 (27%) patients good results, 19 (63%) patients fair results and 2 (7%) patients poor result. In Group B, 14 (47%) patients showed excellent results, 11 (37%) patients good results, 4 (13%) patients fair results and 1 (3%) patient poor result. The outcome score of the Group B patients was significantly better compared to the Group A patients (p value < 0.05). External fixation has definite advantages over conventional Plaster of Paris cast in the treatment of unstable intra-articular fractures of distal radius.
External fixation of “intertrochanteric” fractures
Gani, Naseem ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool
2009-01-01
In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with “intertrochanteric” fractures remain unsuita ble for open reduction and internal fixation. The aim of this study was to analyze the results of external fixation of “intertrochanteric” fractures in high-risk geriatric patients in a developing country. The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58–90 years) with “intertrochanteric” fractures, in whom external fixation was performed, are reported. Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients. This study demonstrated that external fixation of “intertrochantric” fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country. PMID:21808680
Carcinoma of the cervix, stage III. Results of radiation therapy.
Montana, G S; Fowler, W C; Varia, M A; Walton, L A; Mack, Y; Shemanski, L
1986-01-01
From April 1969 through December 1980, 203 patients with Stage III epidermoid carcinoma of the cervix were treated with radiation therapy with curative intent. The disease-free survival at 2, 5, and 10 years was 50%, 33%, and 27%, respectively. The survival was better for patients with Stage IIIB disease than for those with Stage IIIA disease. Eighty-eight patients were treated with external beam therapy only, and 115 received external beam and brachytherapy. The disease-free survival was better for the combination therapy group initially, but this difference was not sustained beyond 5 years. One hundred eight patients experienced recurrence within the irradiated field, for a locoregional recurrence rate of 53%. Twenty-seven patients had complications (13%). The complications were mild in 13 patients, moderate in 4 patients, and severe in 10 patients. A study was made of the relationship of the dose to Point A and the occurrence of complications. Similar analyses were made of the bladder and rectal doses and the subsequent occurrence of urinary and intestinal complications. In these analyses, the mean dose to Point A and the critical organs was higher for the groups of patients with complications than for those patients without complications. This relationship was also observed when the patients were stratified for treatment with either external beam plus brachytherapy or external beam therapy alone.
Okuyama, Hidenobu; Hirono, Osamu; Ishigaki, Daisuke; Yuki, Koichi; Kubota, Isao
2010-01-01
A 59-year-old man visited our hospital due to right leg edema and right leg pain. Computed tomography revealed that the circumferential enhancement of bilateral external iliac arteries by soft tissue that had similar density as the adjacent psoas muscle and that the right external iliac vein that was constricted by those tissues. The patient was diagnosed as retroperitoneal fibrosis. He underwent stent implantation to the right external iliac vein stenosis and steroid therapy. His right leg edema and pain was immediately improved after the stent implantation and he achieved remission.
Wang, Yicun; Jiang, Hui; Deng, Zhantao; Jin, Jiewen; Meng, Jia; Wang, Jun; Zhao, Jianning; Sun, Guojing; Qian, Hongbo
2017-01-01
To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled.
Wang, Yicun; Jiang, Hui; Deng, Zhantao; Meng, Jia; Wang, Jun
2017-01-01
Background To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. Methods 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Results Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. Conclusions It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled. PMID:29333448
Rigid external maxillary distraction and rhinoplasty for pyknodysostosis.
Varol, Altan; Sabuncuoglu, Fidan Alakus; Sencimen, Metin; Akcam, Timur; Olmez, Hüseyin; Basa, Selçuk
2011-05-01
This article reports the treatment of an 33-year-old female patient with pyknodysostosis by rigid external distraction II midface distraction system. The patient with pyknodysostosis described in this report had severe midfacial hypoplasia. Correction of this by use of routine orthognathic surgery would require osteosynthesis and bone grafting. Risk of infection and/or nonunion after such a surgical procedure was considered too great, and therefore the possibility of treatment by distraction osteogenesis of the maxilla was evaluated. The rigid external distraction II midface distraction system was used to relocate the hypoplastic maxilla at anterior-inferior projection. Distraction osteogenesis should be considered as the primary reconstructive method for maxillofacial deformities in patients with sclerosing bone dysplasias, since this is the second reported case treated successfully with rigid external distraction.
Gutkowska, Olga; Martynkiewicz, Jacek; Gosk, Jerzy
2017-01-01
Anterior glenohumeral dislocation affects about 2% of the general population during the lifetime. The incidence of traumatic glenohumeral dislocation ranges from 8.2 to 26.69 per 100 000 population per year. The most common complication is recurrent dislocation occurring in 17–96% of the patients. The majority of patients are treated conservatively by closed reduction and immobilization in internal rotation for 2–3 weeks. However, no clear conservative treatment protocol exists. Immobilization in external rotation can be considered an alternative. A range of external rotation braces are commercially available. The purpose of this work was to review the current literature on conservative management of glenohumeral dislocation and to compare the results of immobilization in internal and external rotation. A comprehensive literature search and review was performed using the keywords “glenohumeral dislocation”, “shoulder dislocation”, “immobilization”, “external rotation”, and “recurrent dislocation” in PubMed, MEDLINE, Cochrane Library, Scopus, and Google Scholar databases from their inceptions to May 2016. Three cadaveric studies, 6 imaging studies, 10 clinical studies, and 4 meta-analyses were identified. The total number of 734 patients were included in the clinical studies. Literature analysis revealed better coaptation of the labrum on the glenoid rim in external rotation in cadaveric and imaging studies. However, this tendency was not confirmed by lower redislocation rates or better quality of life in clinical studies. On the basis of the available literature, we cannot confirm the superiority of immobilization in external rotation after glenohumeral dislocation when compared to internal rotation. A yet-to-be-determined group of patients with specific labroligamentous injury pattern may benefit from immobilization in external rotation. Further studies are needed to identify these patients. PMID:28710344
External airway splint to treat tracheomalacia following laryngotracheal reconstruction.
Hsueh, Wayne D; Smith, Lee P
2017-03-01
This observation reports the use of an external airway splint to treat tracheomalacia in a pediatric patient. The patient underwent a double stage laryngotracheal reconstruction however was unable to be decannulated due to severe tracheomalacia. Our purpose is to further support the use of external splinting in the treatment of tracheomalacia in a unique case involving isolated nighttime airway obstruction following laryngotracheal reconstruction. Copyright © 2017 Elsevier B.V. All rights reserved.
The use of cognitive-behavioral treatment including hypnosis for claustrophobia in cancer patients.
Steggles, S
1999-04-01
Two case studies are reported to illustrate the use of a comprehensive cognitive-behavioral approach to treat claustrophobia in cancer patients undergoing external beam radiation therapy. Hypnosis was an essential component of the cognitive-behavioral approach. Both patients responded favorably to the psychological intervention and completed the required external beam radiation therapy.
Buek, John D; McVearry, Ingrid; Lim, Elaine; Landy, Helain; Afriyie-Gray, Akua
2005-06-01
After hospitalization subsequent to preterm premature rupture of membranes at 29 weeks, our patient was scheduled for induction of labor at 34 weeks. When the fetus was found to be breech with oligohydramnios, amnioinfusion was performed to facilitate external cephalic version, and this successful procedure enabled the patient to deliver vaginally.
Liquid Nitrogen Cryotherapy for Surface Eye Disease (An AOS Thesis)
Fraunfelder, Frederick Web
2008-01-01
Purpose To evaluate the effects of new treatments with liquid nitrogen cryotherapy on some external eye conditions. Methods In this retrospective case study, 6 separate series from a single tertiary care referral center practice are described. Liquid nitrogen cryotherapy was used to treat conjunctival amyloidosis, primary pterygia, recurrent pterygia, advancing wavelike epitheliopathy (AWLE), superior limbic keratoconjunctivitis (SLK), and palpebral vernal keratoconjunctivitis (VKC). The main outcome measure was the resolution of the disease process after treatment. Results Four patients with primary localized conjunctival amyloidosis were treated with liquid nitrogen cryotherapy. Two of them had recurrence of the amyloidosis, which cleared with subsequent treatment. Eighteen patients with primary pterygia had excision and cryotherapy with 1 recurrence. Of 6 subjects who presented with recurrent pterygia, 4 had a second recurrence after excision and cryotherapy. In 5 patients with AWLE, the condition resolved within 2 weeks without recurrence or the need for subsequent cryotherapy. Four patients with SLK were treated with liquid nitrogen cryotherapy. Disease recurred in 2 patients and 3 of 7 eyes, although subsequent cryotherapy eradicated SLK in all cases. Two patients and 3 eyelids with palpebral VKC were treated with liquid nitrogen cryotherapy. VKC recurred in all cases. Conclusions Liquid nitrogen cryotherapy to the surface of the eye is effective in treating AWLE, and SLK. Excision followed by cryotherapy is successful in treating conjunctival amyloidosis and primary pterygia Liquid nitrogen cryotherapy is unsuccessful in the treatment of recurrent pterygia and VKC. PMID:19277243
Surrogate-driven deformable motion model for organ motion tracking in particle radiation therapy
NASA Astrophysics Data System (ADS)
Fassi, Aurora; Seregni, Matteo; Riboldi, Marco; Cerveri, Pietro; Sarrut, David; Battista Ivaldi, Giovanni; Tabarelli de Fatis, Paola; Liotta, Marco; Baroni, Guido
2015-02-01
The aim of this study is the development and experimental testing of a tumor tracking method for particle radiation therapy, providing the daily respiratory dynamics of the patient’s thoraco-abdominal anatomy as a function of an external surface surrogate combined with an a priori motion model. The proposed tracking approach is based on a patient-specific breathing motion model, estimated from the four-dimensional (4D) planning computed tomography (CT) through deformable image registration. The model is adapted to the interfraction baseline variations in the patient’s anatomical configuration. The driving amplitude and phase parameters are obtained intrafractionally from a respiratory surrogate signal derived from the external surface displacement. The developed technique was assessed on a dataset of seven lung cancer patients, who underwent two repeated 4D CT scans. The first 4D CT was used to build the respiratory motion model, which was tested on the second scan. The geometric accuracy in localizing lung lesions, mediated over all breathing phases, ranged between 0.6 and 1.7 mm across all patients. Errors in tracking the surrounding organs at risk, such as lungs, trachea and esophagus, were lower than 1.3 mm on average. The median absolute variation in water equivalent path length (WEL) within the target volume did not exceed 1.9 mm-WEL for simulated particle beams. A significant improvement was achieved compared with error compensation based on standard rigid alignment. The present work can be regarded as a feasibility study for the potential extension of tumor tracking techniques in particle treatments. Differently from current tracking methods applied in conventional radiotherapy, the proposed approach allows for the dynamic localization of all anatomical structures scanned in the planning CT, thus providing complete information on density and WEL variations required for particle beam range adaptation.
Tweed, M; Tweed, C; Perkins, G D
2001-11-01
External chest compression (ECC) efficacy is influenced by factors including the surface supporting the patient. Air-filled support surfaces are deflated for cardiopulmonary resuscitation, with little evidence to substantiate this. We investigated the effect that differing support surfaces had on ECC efficacy using a CPR manikin model. Four participants carried out four cycles of ECC with an assistant ventilating. The subjects were blinded to the seven support surfaces and the order was randomised. For each participant/surface combination, ECC variables and the participants' perceptions were measured. Participants produced effective ECC with the manikin on the floor (mean proportion correct, 94.5%; mean depth, 42.5 mm). Compared with the floor: the proportion of correct ECC was less for the overlay inflated (P<0.05); the depth of ECC was less effective (30-37 mm) for the overlay inflated/deflated and low-air-loss inflated and foam mattresses (P<0.05). The foam mattress, overlay inflated/deflated, and low-air-loss inflated were perceived as being less stable and as having reduced ECC efficacy compared with the floor. There was no difference or agreement, regarding subjects' perceptions or ECC variables, between the support surfaces or between inflated/deflated air-filled support surfaces. The efficacy of ECC is affected by the support surfaces. There seems little evidence to substantiate deflating all air-filled support surfaces for CPR.
Tsuchiya, Hiroyuki; Abdel-Wanis, Mohamed E; Kitano, Shinji; Sakurakichi, Keisuke; Yamashiro, Teruhisa; Tomita, Katsuro
2002-01-01
This paper introduces an innovative technique of highly conservative limb-saving surgery for juxta-articular osteosarcoma. This technique consists of marginal tumour excision, joint preservation and reconstruction by distraction osteogenesis. Ten patients, with a mean age of 19.5 years and high-grade osteosarcoma, underwent this procedure. The distal femur and proximal tibia were affected in five patients each. After effective pre-operative chemotherapy, the tumour was excised with preservation of the epiphysis, the articular surface and the maximun amount of healthy soft tissue. This was followed by application of an external fixator. Bone transport was performed for seven patients and shortening-distraction for three. The limb function was rated excellent in seven patients, good in one and fair in two. At the final follow-up, three patients were dead after a mean of 25.3 months while seven patients remained free of disease with a mean follow-up of 55.4 months. Joint preservation and biological reconstruction through distraction osteogenesis can produce excellent and long-lasting functional results.
Prevalence of Campylobacter, Salmonella, and Escherichia coli on the external packaging of raw meat.
Burgess, F; Little, C L; Allen, G; Williamson, K; Mitchelli, R T
2005-03-01
During September and October 2002, 3,662 prepackaged raw meat samples were collected to evaluate the extent and nature of microbiological contamination on external surfaces of the packaging, which could potentially cross-contaminate ready-to-eat foods during and after purchase. Salmonella was detected on two (<1%) samples of external packaging (both from raw chicken), and Campylobacter was detected on 41 (1.1%) samples of external packaging. The external packaging of game fowl exhibited the highest Campylobacter contamination (3.6%), followed by raw chicken (3.0%), lamb (1.6%), turkey (0.8%), pork (0.2%), and beef (0.1%); Campylobacter jejuni and Campylobacter coli accounted for 59% (24 of 41) and 24% (10 of 41) of the contaminating Campylobacter species, respectively. C. coli isolates from the external packaging were more multiresistant to antimicrobial drugs, including quinolones such as ciprofloxacin, than was C. jejuni. Escherichia coli (an indicator of fecal contamination) was isolated from the external packaging on 4% of the raw meat samples at levels of 40 to 10(5) CFU per swab. The external packaging of raw meats is a vehicle for potential cross-contamination by Campylobacter, Salmonella, and E. coli in retail premises and consumers' homes. The external surface of heat-sealed packaging was less frequently contaminated with Campylobacter and E. coli compared with other types of packaging (e.g., overwrapping, bag, and tie tape) (P < 0.0001 to 0.01). In addition, external packaging of raw meats was contaminated less frequently with Campylobacter and E. coli when packaging was intact, packaging and display areas were visually clean, display temperatures were below 8 degrees C, and hazard analysis systems were in place.
Experiencing authenticity - the core of student learning in clinical practice.
Manninen, Katri
2016-10-01
Learning in clinical practice is challenging regarding organizational and pedagogical issues. Clinical education wards are one way to meet these challenges by focusing on both patient care and student learning. However, more knowledge is needed about how students' learning can be enhanced and about patients' and supervisors' roles in these settings. The aim was to explore nursing students' learning on a clinical education ward with an explicit pedagogical framework. Semi-structured interviews of students were analyzed using qualitative content analysis and an ethnographic study including observations and follow-up interviews of students, patients and supervisors was conducted. The core of student meaningful learning experiences both external and internal authenticity. Students in early stages immediately created mutual relationships, experienced both external and internal authenticity, and patients became active participants in student learning. Without a mutual relationship, patients passively let students practice on their bodies. Students nearing graduation experienced only external authenticity, creating uncertainty as a threshold for learning. Caring for patients with complex needs helped students overcome the threshold and experience internal authenticity. Supervisors' challenges were to balance patient care and student learning by working as a team. They supported students coping with the complex challenges on the ward. Students need to experience external and internal authenticity to make learning meaningful. Experiencing authenticity, involving meaning-making processes and knowledge construction, is linked to transformative learning and overcoming thresholds. Therefore, an explicit pedagogical framework, based on patient-centredness, peer learning and the supervisory team, creates the prerequisites for experiencing external and internal authenticity.
Calcium distribution in Amoeba proteus
1979-01-01
A preliminary investigation of the distribution of cellular calcium in Amoeba proteus was undertaken. Total cellular calcium under control conditions was found to be 4.59 mmol/kg of cells. When the external Ca++ concentration is increased from the control level of 0.03 to 20 mM, a net Ca++ influx results with a new steady-state cellular calcium level being achieved in integral of 3 h. At steady state the amount of calcium per unit weight of cells is higher than the amount of calcium per unit weight of external solution when the external concentration of Ca++ is below 10 mM. At external Ca++ concentrations above this level, total cellular calcium approaches the medium level of Ca++. Steady- state calcium exchange in Amoeba proteus was determined with 45Ca. There is an immediate and rapid exchange of integral of 0.84 mmol/kg of cells or 18% of the total cellular calcium with the labelled Ca++. Following this initial exchange, there was very little if any further exchange observed. Most of this exchanged calcium could be eliminated from the cell with 1 mM La+++, suggesting that the exchanged calcium is associated with the surface of the cell. Increase in either the external Ca++ concentration of pH raise the amount of exchangeable calcium associated with the cell. Calcium may be associated with the cell surface as a co-ion in the diffuse double layer or bound to fixed negative sites on the surface of the cell. If Ca++-binding sites do exist on the cell surface, there may be more than one type and they may have different dissociation constants. The cytoplasmic Ca++ ion activity is probably maintained at very low levels. PMID:512628
Bluetooth technology for prevention of dental caries.
Kolahi, Jafar; Fazilati, Mohamad
2009-12-01
Caries is caused when the pH at the tooth surface drops below 5.5. A miniaturized and autonomous pH monitoring nodes can be attached to the tooth surface, like a tooth jewel. This intelligent sensor includes three components: (a) digital micro pH meter, (b) power supply, (c) wireless communicating device. The micro pH meter facilitates long term tooth surface pH monitoring and providing real time feedback to the patients and dental experts. Power supply of this system will be microfabricated biocatalytic fuel cell (enzymatic micro-battery) using organic compounds (e.g. formate or glucose) as the fuel to generate electricity. When micro pH meter detects the pH lower than 5.5, wireless Bluetooth device sends a caution (e.g. "you are at risk of dental caries") to external monitoring equipment such as mobile phone or a hands-free heads. After reception of the caution, subjects should use routine brushing and flossing procedure or use a medicated chewing gum (e.g. chlorhexidine containing chewing gum) or rinse with a mouthwash.
Stoppers in RED II distraction device: is it possible to prevent pin migration?
Mavili, Mehmet Emin; Vargel, Ibrahim; Tunçbilek, Gökhan
2004-05-01
Distraction osteogenesis has become popular for the treatment of hypoplastic congenital craniomaxillofacial anomalies. Rigid external distraction (RED II) after Le Fort III osteotomy was shown to be a highly effective treatment for the management of midface hypoplasia. This device is used with a halo vest, which is placed at the cranial equator. Intracranial penetration of the fixation pins of the halo is one of the complications of an external distraction device. To prevent pin penetration in rigid external distraction, the authors designed polylactic acid/polyglycolic acid (PLA/PGA) plates that were circular; the plates were 0.8 cm in diameter and had 1.5-mm holes in the center, through which the tip of the pins would pass. To quantify the applied torque by manual tightening of the screws of the distraction device and to measure intraosseous cone depth created by the penetration of the conical part of the screws with and without the PLA/PGA composite stopper, first an in vitro experiment was undertaken on cadaver. Then these PLA/PGA plaques, or stoppers, were placed over the bone surfaces of the cranium of the patients where the tip of the pins press. PLA/PGA stoppers are malleable and adapt their shape to the interactive forces between bone and the pins. They act as a second barrier, and spread the pressure of the screws to larger surfaces, thus securing better stabilization. The penetration of wider portions of the screw into scalp is reduced, minimizing the scalp damage caused by the screws. Biodegradable and biocompatible PLA/PGA stoppers avoid intracranial migration of the fixation pins, especially in children.
Perdzyński, Wojciech; Adamek, Marek
2017-01-01
The aim of the study was to report methods - based on penile anatomy - leading to the minimization in the invasiveness of reconstructive surgery for congenital penile curvature (CPC). From 2006 to 2016 authors operated on 186 adult men with CPC.To avoid degloving, the authors used the longitudinal skin and tunica dartos incision. For decreasing invasiveness to the dorsal neurovascular bundle (NVB), the authors separated it only locally in the shape of a triangle or a trapezium, elevating it only over the place of the tunical reconstruction. To decrease the invasiveness for the tunica albuginea (TA) and cavernous vessels, a new operative technique based on the stratified structure of the TA was developed in which the corpora cavernosa were not opened. During reconstruction, only the elliptical fragment of the external layer of the tunica was excised (internal layer was left intact) and both layers of the tunica were sutured over the invaginated internal layer. Follow-up ranged from 6 months to 10 years. In all the patients, the penis was straightened during operation. Follow-up examinations were done 6 months and 1 year postoperatively. Disorders of superficial sensation on the glans, erectile dysfunction or chronic postoperative edema were not detected in any of the 186 patients. The penis remained straight in 180 patients (96.7%). In 4 patients (2.2%) in whom the primary curvature was 80-90 degrees and the postoperative curvature was about 30 degrees, reoperation was done. In two patients (1.1%) with the remaining postoperative curvature up to 20 degrees and good functional result (patient's opinion), there was no need for further treatment. Longitudinal skin and tunica dartos incision on the convex surface of the penis allows for the ability to avoid penile degloving and to preserve the foreskin. Elevation of the dorsal NVB from the TA was done on a very limited surface in the shape of triangle or trapezium, in order to decrease the possibility of dorsal nerves/vessels damage. Excision of elliptical fragments of the external layer of the TA with subsequent invagination of the internal layer, excluded the need for opening of the corpora cavernosa as well as for the use of a tourniquet during reconstruction. This diminished the potential risk of complications, especially intra- and postoperative bleeding.
Thermally tailored gradient topography surface on elastomeric thin films.
Roy, Sudeshna; Bhandaru, Nandini; Das, Ritopa; Harikrishnan, G; Mukherjee, Rabibrata
2014-05-14
We report a simple method for creating a nanopatterned surface with continuous variation in feature height on an elastomeric thin film. The technique is based on imprinting the surface of a film of thermo-curable elastomer (Sylgard 184), which has continuous variation in cross-linking density introduced by means of differential heating. This results in variation of viscoelasticity across the length of the surface and the film exhibits differential partial relaxation after imprinting with a flexible stamp and subjecting it to an externally applied stress for a transient duration. An intrinsic perfect negative replica of the stamp pattern is initially created over the entire film surface as long as the external force remains active. After the external force is withdrawn, there is partial relaxation of the applied stresses, which is manifested as reduction in amplitude of the imprinted features. Due to the spatial viscoelasticity gradient, the extent of stress relaxation induced feature height reduction varies across the length of the film (L), resulting in a surface with a gradient topography with progressively varying feature heights (hF). The steepness of the gradient can be controlled by varying the temperature gradient as well as the duration of precuring of the film prior to imprinting. The method has also been utilized for fabricating wettability gradient surfaces using a high aspect ratio biomimetic stamp. The use of a flexible stamp allows the technique to be extended for creating a gradient topography on nonplanar surfaces as well. We also show that the gradient surfaces with regular structures can be used in combinatorial studies related to pattern directed dewetting.
Scattered Atomic Oxygen Effects on Spacecraft Materials
NASA Technical Reports Server (NTRS)
Banks, Bruce A.; Miller, Sharon K. R.; deGroh, Kim K.; Demko, Rikako
2003-01-01
Low Earth orbital (LEO) atomic oxygen cannot only erode the external surfaces of polymers on spacecraft, but can cause degradation of surfaces internal to components on the spacecraft where openings to the space environment exist. Although atomic oxygen attack on internal or interior surfaces may not have direct exposure to the LEO atomic oxygen flux scattered impingement can have serious degradation effects where sensitive interior surfaces are present. The effects of atomic oxygen erosion of polymer interior to an aperture on a spacecraft is simulated using Monte Carlo computational techniques. A 2-dimensional model is used to provide quantitative indications of the attenuation of atomic oxygen flux as a function of distance into a parallel walled cavity. The degree of erosion re1ative is compared between the various interior locations and the external surface of a LEO spacecraft.
Atomic Oxygen Effects on Spacecraft Materials
NASA Technical Reports Server (NTRS)
Banks, Bruce A.; Miller, Sharon K. R.; deGroh, Kim K.; Demko, Rikako
2003-01-01
Low Earth orbital (LEO) atomic oxygen cannot only erode the external surfaces of polymers on spacecraft, but can cause degradation of surfaces internal to components on the spacecraft where openings to the space environment exist. Although atomic oxygen attack on internal or interior surfaces may not have direct exposure to the LEO atomic oxygen flux, scattered impingement can have can have serious degradation effects where sensitive interior surfaces are present. The effects of atomic oxygen erosion of polymers interior to an aperture on a spacecraft is simulated using Monte Carlo computational techniques. A 2-dimensional model is used to provide quantitative indications of the attenuation of atomic oxygen flux as a function of distance into a parallel walled cavity. The degree of erosion relative is compared between the various interior locations and the external surface of an LEO spacecraft.
Soravia, Leila M; Schläfli, Katrin; Stutz, Sonja; Rösner, Susanne; Moggi, Franz
2015-11-01
There is evidence that drinking during residential treatment is related to various factors, such as patients' general control beliefs and self-efficacy, as well as to external control of alcohol use by program's staff and situations where there is temptation to drink. As alcohol use during treatment has been shown to be associated with the resumption of alcohol use after discharge from residential treatment, we aimed to investigate how these variables are related to alcohol use during abstinence-oriented residential treatment programs for alcohol use disorders (AUD). In total, 509 patients who entered 1 of 2 residential abstinence-oriented treatment programs for AUD were included in the study. After detoxification, patients completed a standardized diagnostic procedure including interviews and questionnaires. Drinking was assessed by patients' self-report of at least 1 standard drink or by positive breathalyzer testing. The 2 residential programs were categorized as high or low control according to the average number of tests per patient. Regression analysis revealed a significant interaction effect between internal and external control suggesting that patients with high internal locus of control and high frequency of control by staff demonstrated the least alcohol use during treatment (16.7%) while patients with low internal locus of control in programs with low external control were more likely to use alcohol during treatment (45.9%). No effects were found for self-efficacy and temptation. As alcohol use during treatment is most likely associated with poor treatment outcomes, external control may improve treatment outcomes and particularly support patients with low internal locus of control, who show the highest risk for alcohol use during treatment. High external control may complement high internal control to improve alcohol use prevention while in treatment. Copyright © 2015 The Authors. Alcoholism: Clinical and Experimental Research published by Wiley Periodicals, Inc. on behalf of Research Society on Alcoholism.
[Problems with placement and using of automated external defibrillators in Czech Republic].
Olos, Tomás; Bursa, Filip; Gregor, Roman; Holes, David
2011-01-01
The use of automated external defibrillators improves the survival of adults who suffer from cardiopulmonary arrest. Automated external defibrillators detect ventricular fibrillation with almost perfect sensitivity and specificity. Authors describe the use of automated external defibrillator during cardiopulmonary resuscitation in a patient with sudden cardiac arrest during ice-hockey match. The article reports also the use of automated external defibrillators in children.
Musani, Ali I; Jensen, Kurt; Mitchell, John D; Weyant, Michael; Garces, Katherine; Hsia, David
2012-04-01
Benign tracheal obstruction occurs for a variety of reasons. Bronchoscopic intervention includes silicone stent placement, which effectively maintains airway patency. Stent migration is a common complication, particularly when placed in the proximal trachea. We used a novel technique of securing tracheal stents with a percutaneous endoscopic gastrostomy tube fastener (PEG-TF) to prevent stent migration. The purpose of this study was to determine the feasibility of securing silicone stents in the proximal trachea with PEG-TF. Silicone stents were placed under general anesthesia by rigid bronchoscopy in 7 consecutive patients with inoperable benign proximal tracheal obstruction. PEG-TFs were placed under sterile conditions with direct bronchoscopic visualization. A needle was inserted through the anterior neck and silicone stent wall allowing stylet introduction of a T-fastener into the interior of the stent. The T-fastener was secured externally by a metal clamp and cotton pledget at the surface of the neck. Patients had routine outpatient follow-up and covered the external portion of the PEG-TF with a waterproof dressing when showering. All 7 PEG-TFs were placed without complications. The PEG-TFs were left in for 1 to 25 weeks. Complications of the PEG-TF included localized cellulitis and suture breakage. No stent migration occurred while the fastener was in place. Two stents were removed within 2 weeks due to patient's difficulty tolerating the stent. Securing silicone stents in the proximal trachea is feasible and may prevent stent migration, but further study and possible modification of the PEG-TF device are needed.
NASA Astrophysics Data System (ADS)
Gaede, Stewart; Carnes, Gregory; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim
2009-01-01
The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing on multiple axial slices and measured the mean CT number versus respiratory phase. Tumour motion was directly correlated with external marker motion, acquired simultaneously, using the sample coefficient of determination, r2. Only three of the ten patients showed correlation higher than r2 = 0.80 between tumour motion and external marker position. However, after taking into account time shifts (ranging between 0 s and 0.4 s) between the two data sets, all ten patients showed correlation better than r2 = 0.8. This non-invasive method for monitoring the motion of internal organs is an effective tool that can assess the use of external markers for 4D-CT imaging and respiratory-gated radiotherapy on a patient-specific basis.
Gaede, Stewart; Carnes, Gregory; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim
2009-01-21
The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing on multiple axial slices and measured the mean CT number versus respiratory phase. Tumour motion was directly correlated with external marker motion, acquired simultaneously, using the sample coefficient of determination, r(2). Only three of the ten patients showed correlation higher than r(2) = 0.80 between tumour motion and external marker position. However, after taking into account time shifts (ranging between 0 s and 0.4 s) between the two data sets, all ten patients showed correlation better than r(2) = 0.8. This non-invasive method for monitoring the motion of internal organs is an effective tool that can assess the use of external markers for 4D-CT imaging and respiratory-gated radiotherapy on a patient-specific basis.
A Digital Map From External Forcing to the Final Surface Warming Pattern and its Seasonal Cycle
NASA Astrophysics Data System (ADS)
Cai, M.
2015-12-01
Historically, only the thermodynamic processes (e.g., water vapor, cloud, surface albedo, and atmospheric lapse rate) that directly influence the top of the atmosphere (TOA) radiative energy flux balance are considered in climate feedback analysis. One of my recent research areas is to develop a new framework for climate feedback analysis that explicitly takes into consideration not only the thermodynamic processes that the directly influence the TOA radiative energy flux balance but also the local dynamical (e.g., evaporation, surface sensible heat flux, vertical convections etc) and non-local dynamical (large-scale horizontal energy transport) processes in aiming to explain the warming asymmetry between high and low latitudes, between ocean and land, and between the surface and atmosphere. In the last 5-6 years, we have developed a coupled atmosphere-surface climate feedback-response analysis method (CFRAM) as a new framework for estimating climate feedback and sensitivity in coupled general circulation models with a full physical parameterization package. In the CFRAM, the isolation of partial temperature changes due to an external forcing alone or an individual feedback is achieved by solving the linearized infrared radiation transfer model subject to individual energy flux perturbations (external or due to feedbacks). The partial temperature changes are addable and their sum is equal to the (total) temperature change (in the linear sense). The CFRAM is used to isolate the partial temperature changes due to the external forcing, due to water vapor feedback, clouds, surface albedo, local vertical convection, and non-local atmospheric dynamical feedbacks, as well as oceanic heat storage. It has been shown that seasonal variations in the cloud feedback, surface albedo feedback, and ocean heat storage/dynamics feedback, directly caused by the strong annual cycle of insolation, contribute primarily to the large seasonal variation of polar warming. Furthermore, the CO2 forcing, and water vapor and atmospheric dynamics feedbacks add to the maximum polar warming in fall/winter.
Electromyographical Comparison of Four Common Shoulder Exercises in Unstable and Stable Shoulders
Sciascia, Aaron; Kuschinsky, Nina; Nitz, Arthur J.; Mair, Scott D.; Uhl, Tim L.
2012-01-01
This study examines if electromyographic (EMG) amplitude differences exist between patients with shoulder instability and healthy controls performing scaption, prone horizontal abduction, prone external rotation, and push-up plus shoulder rehabilitation exercises. Thirty nine subjects were categorized by a single orthopedic surgeon as having multidirectional instability (n = 10), anterior instability (n = 9), generalized laxity (n = 10), or a healthy shoulder (n = 10). Indwelling and surface electrodes were utilized to measure EMG activity (reported as a % of maximum voluntary isometric contraction (MVIC)) in various shoulder muscles during 4 common shoulder exercises. The exercises studied effectively activated the primary musculature targeted in each exercise equally among all groups. The serratus anterior generated high activity (50–80% MVIC) during a push-up plus, while the infraspinatus and teres major generated moderate-to-high activity (30–80% MVIC) during both the prone horizontal and prone external rotation exercises. Scaption exercise generated moderate activity (20–50% MVIC) in both rotator cuff and scapular musculature. Clinicians should feel confident in prescribing these shoulder-strengthening exercises in patients with shoulder instability as the activation levels are comparable to previous findings regarding EMG amplitudes and should improve the dynamic stabilization capability of both rotator cuff and scapular muscles using exercises designed to address glenohumeral joint instability. PMID:22919499
Atallah, Vincent; Escarmant, Patrick; Vinh‐Hung, Vincent
2016-01-01
Monitoring and controlling respiratory motion is a challenge for the accuracy and safety of therapeutic irradiation of thoracic tumors. Various commercial systems based on the monitoring of internal or external surrogates have been developed but remain costly. In this article we describe and validate Madibreast, an in‐house‐made respiratory monitoring and processing device based on optical tracking of external markers. We designed an optical apparatus to ensure real‐time submillimetric image resolution at 4 m. Using OpenCv libraries, we optically tracked high‐contrast markers set on patients' breasts. Validation of spatial and time accuracy was performed on a mechanical phantom and on human breast. Madibreast was able to track motion of markers up to a 5 cm/s speed, at a frame rate of 30 fps, with submillimetric accuracy on mechanical phantom and human breasts. Latency was below 100 ms. Concomitant monitoring of three different locations on the breast showed discrepancies in axial motion up to 4 mm for deep‐breathing patterns. This low‐cost, computer‐vision system for real‐time motion monitoring of the irradiation of breast cancer patients showed submillimetric accuracy and acceptable latency. It allowed the authors to highlight differences in surface motion that may be correlated to tumor motion. PACS number(s): 87.55.km PMID:27685116
Leduc, Nicolas; Atallah, Vincent; Escarmant, Patrick; Vinh-Hung, Vincent
2016-09-08
Monitoring and controlling respiratory motion is a challenge for the accuracy and safety of therapeutic irradiation of thoracic tumors. Various commercial systems based on the monitoring of internal or external surrogates have been developed but remain costly. In this article we describe and validate Madibreast, an in-house-made respiratory monitoring and processing device based on optical tracking of external markers. We designed an optical apparatus to ensure real-time submillimetric image resolution at 4 m. Using OpenCv libraries, we optically tracked high-contrast markers set on patients' breasts. Validation of spatial and time accuracy was performed on a mechanical phantom and on human breast. Madibreast was able to track motion of markers up to a 5 cm/s speed, at a frame rate of 30 fps, with submillimetric accuracy on mechanical phantom and human breasts. Latency was below 100 ms. Concomitant monitoring of three different locations on the breast showed discrepancies in axial motion up to 4 mm for deep-breathing patterns. This low-cost, computer-vision system for real-time motion monitoring of the irradiation of breast cancer patients showed submillimetric accuracy and acceptable latency. It allowed the authors to highlight differences in surface motion that may be correlated to tumor motion.v. © 2016 The Authors.
Ilizarov bone transport versus fibular graft for reconstruction of tibial bone defects in children.
Abdelkhalek, Mostafa; El-Alfy, Barakat; Ali, Ayman M
2016-11-01
The aim of this study was to compare the results of treatment of segmental tibial defects in the pediatric age group using an Ilizarov external fixator versus a nonvascularized fibular bone graft. This study included 24 patients (age range from 5.5 to 15 years) with tibial bone defects: 13 patients were treated with bone transport (BT) and 11 patients were treated with a nonvascularized fibular graft (FG). The outcome parameters were bone results (union, deformity, infection, leg-length discrepancy) and functional results: external fixation index and external fixation time. In group A (BT), one patient developed refracture at the regenerate site, whereas, in group B (FG), after removal of the external fixator, one of the FGs developed a stress fracture. The external fixator time in group A was 10.7 months (range 8-14.5) versus 7.8 months (range 4-11.5 months) in group B (FG). In group A (BT), one patient had a limb-length discrepancy (LLD), whereas, in group B (FG), three patients had LLD. The functional and bone results of the Ilizarov BT technique were excellent in 23.1 and 30.8%, good in 38.5 and 46.2, fair in 30.8 and 15.4, and poor in 7.6 and 7.6%, respectively. The poor functional result was related to the poor bone result because of prolonged external fixator time resulting in significant pain, limited ankle motion, whereas the functional and bone results of fibular grafting were excellent in 9.1 and 18.2%, good in 63.6 and 45.5%, fair in 18.2 and 27.2%, and poor in 9.1 and 9.1%, respectively. Segmental tibial defects can be effectively treated with both methods. The FG method provides satisfactory results, with early removal of the external fixator. However, it had a limitation in patients with severe infection and those with LLD. Also, it requires a long duration of limb bracing until adequate hypertrophy of the graft. The Ilizarov method has the advantages of early weight bearing, treatment of postinfection bone defect in a one-stage surgery, and the possibility to treat the associated LLD. However, it has a long external fixation time.
Can insertion length for a double-lumen endobronchial tube be predicted?
Dyer, R A; Heijke, S A; Russell, W J; Bloch, M B; James, M F
2000-12-01
It has been suggested that the appropriate length of insertion for double-lumen tubes can be estimated by external measurement. This study examined the accuracy of external measurement in estimating the actual length of insertion required in 130 patients. It also examined the relationship between the length inserted and the patient's height in 126 patients and their weight in 125 patients. Although there was a fair correlation between the measured external length and the final inserted length (r = 0.61), the 95% confidence intervals of slope and intercept allowed a large variation and the prediction was too wide to be clinically useful. Height was reasonably well correlated with the final length (r = 0.51) but an equally wide 95% confidence interval rendered it of little clinical value. There was no correlation between weight and final tube length. It is concluded that external measurement alone is not adequate to predict a clinically acceptable position of the double-lumen tube.
External front instabilities induced by a shocked particle ring.
Rodriguez, V; Saurel, R; Jourdan, G; Houas, L
2014-10-01
The dispersion of a cylindrical particle ring by a blast or shock wave induces the formation of coherent structures which take the form of particle jets. A blast wave, issuing from the discharge of a planar shock wave at the exit of a conventional shock tube, is generated in the center of a granular medium ring initially confined inside a Hele-Shaw cell. With the present experimental setup, under impulsive acceleration, a solid particle-jet formation is observed in a quasi-two-dimensional configuration. The aim of the present investigation is to observe in detail the formation of very thin perturbations created around the external surface of the dispersed particle layer. By means of fast flow visualization with an appropriate recording window, we focus solely on the first instants during which the external particle ring becomes unstable. We find that the critical area of the destabilization of the external ring surface is constant regardless of the acceleration of the initial layer. Moreover, we observe in detail the external front perturbation wavelength, rendered dimensionless by the initial ring perimeter, and follow its evolution with the initial particle layer acceleration. We report this quantity to be constant regardless of the evolution of the initial particle layer acceleration. Finally, we can reasonably assert that external front perturbations depend solely on the material of the particles.
Design of sEMG assembly to detect external anal sphincter activity: a proof of concept.
Shiraz, Arsam; Leaker, Brian; Mosse, Charles Alexander; Solomon, Eskinder; Craggs, Michael; Demosthenous, Andreas
2017-10-31
Conditional trans-rectal stimulation of the pudendal nerve could provide a viable solution to treat hyperreflexive bladder in spinal cord injury. A set threshold of the amplitude estimate of the external anal sphincter surface electromyography (sEMG) may be used as the trigger signal. The efficacy of such a device should be tested in a large scale clinical trial. As such, a probe should remain in situ for several hours while patients attend to their daily routine; the recording electrodes should be designed to be large enough to maintain good contact while observing design constraints. The objective of this study was to arrive at a design for intra-anal sEMG recording electrodes for the subsequent clinical trials while deriving the possible recording and processing parameters. Having in mind existing solutions and based on theoretical and anatomical considerations, a set of four multi-electrode probes were designed and developed. These were tested in a healthy subject and the measured sEMG traces were recorded and appropriately processed. It was shown that while comparatively large electrodes record sEMG traces that are not sufficiently correlated with the external anal sphincter contractions, smaller electrodes may not maintain a stable electrode tissue contact. It was shown that 3 mm wide and 1 cm long electrodes with 5 mm inter-electrode spacing, in agreement with Nyquist sampling, placed 1 cm from the orifice may intra-anally record a sEMG trace sufficiently correlated with external anal sphincter activity. The outcome of this study can be used in any biofeedback, treatment or diagnostic application where the activity of the external anal sphincter sEMG should be detected for an extended period of time.
Awais, Syed; Saeed, Ayesha; Ch, Asad
2014-08-01
In the 2005 Pakistan earthquake, the great many injured with multiple fractures and open wounds provided a unique opportunity to practice damage-control orthopaedics. External fixators remain a time-tested tools for operating surgeons on such occasions. The locally manufactured, readily available Naseer-Awais (NA) external fixator filled such needs of this disaster with good outcome. This is a retrospective descriptive study of 19,700 patients that presented over seven months to the two centres established by the lead author (SMA) in Muzaffarabad and Mansehra just one night after the 2005 earthquake. A series of local and foreign orthopaedic surgeon teams operated in succession. The computerised patient data collection of 1,145 operations was retrospectively analysed. Of the 19,700 patients presenting to the SMA centres, 50% had limb injuries. Total fracture fixations were 1,145, of which 295 were external fixations: 185 were applied on the lower limb and 90 on upper limb, the majority were applied on tibia. External fixators are valuable damage-control tools in natural disasters and warfare injuries. The locally manufactured NA external fixator served the needs of the many limb injuries during the 2005 Pakistan earthquake.
[Clinical and empirical findings with the OPD-CA].
Winter, Sibylle; Jelen, Anna; Pressel, Christine; Lenz, Klaus; Lehmkuhl, Ulrike
2011-01-01
60 clinical patients (5-17 years) were diagnosed with an interview-manual of OPD-CA (Winter, 2004). For clinical validity a comparison of patients with internal (N=17) and external disorders (N=19) was shown. References for clinical validity resulted from the comparison of the groups, especially for the axes "conflict" and "prerequisites for treatment". Patients with internal disorders showed the conflict desire for care versus autarchy significantly more often than patients with external disorders. On the other hand patients with external disorders displayed the conflict submission versus control significantly more often. Significant differences were also found for the axis "prerequisites for treatment". Patients with internal disorders had better "prerequisites for treatment" in the domains experience of illness and the prerequisites for therapy. For the axes "interpersonal relation", "structure" and "prerequisites for treatment" satisfactory data for validity and reliability were found. The clinical validity points to the usefulness of OPD-CA-manual for psychodynamic diagnostics in childhood and adolescence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gros, S; Roeske, J; Surucu, M
Purpose: To develop a novel method to monitor external anatomical changes in head and neck cancer patients in order to help guide adaptive radiotherapy decisions. Methods: The method, developed in MATLAB, reveals internal anatomical changes based on variations observed in external anatomy. Weekly kV-CBCT scans from 11 Head and neck patients were retrospectively analyzed. The pre-processing step first corrects each CBCT for artifacts and removes pixels from the immobilization mask to produce an accurate external contour of the patient’s skin. After registering the CBCTs to the initial planning CT, the external contours from each CBCT (CBCTn) are transferred to themore » first week — reference — CBCT{sub 1}. Contour radii, defined as the distances between an external contour and the central pixel of each CBCT slice, are calculated for each scan at angular increments of 1 degree. The changes in external anatomy are then quantified by the difference in radial distance between the external contours of CBCT1 and CBCTn. The radial difference is finally displayed on a 2D intensity map (angle vs radial distance difference) in order to highlight regions of interests with significant changes. Results: The 2D radial difference maps provided qualitative and quantitative information, such as the location and the magnitude of external contour divergences and the rate at which these deviations occur. With this method, anatomical changes due to tumor volume shrinkage and patient weight loss were clearly identified and could be correlated with the under-dosage of targets or over-dosage of OARs. Conclusion: This novel method provides an efficient tool to visualize 3D external anatomical modification on a single 2D map. It quickly pinpoints the location of differences in anatomy during the course of radiotherapy, which can help determine if a treatment plan needs to be adapted.« less
3-D World Modeling For An Autonomous Robot
NASA Astrophysics Data System (ADS)
Goldstein, M.; Pin, F. G.; Weisbin, C. R.
1987-01-01
This paper presents a methodology for a concise representation of the 3-D world model for a mobile robot, using range data. The process starts with the segmentation of the scene into "objects" that are given a unique label, based on principles of range continuity. Then the external surface of each object is partitioned into homogeneous surface patches. Contours of surface patches in 3-D space are identified by estimating the normal and curvature associated with each pixel. The resulting surface patches are then classified as planar, convex or concave. Since the world model uses a volumetric representation for the 3-D environment, planar surfaces are represented by thin volumetric polyhedra. Spherical and cylindrical surfaces are extracted and represented by appropriate volumetric primitives. All other surfaces are represented using the boolean union of spherical volumes (as described in a separate paper by the same authors). The result is a general, concise representation of the external 3-D world, which allows for efficient and robust 3-D object recognition.
Lundberg, Hannah J; Rojas, Idubijes L; Foucher, Kharma C; Wimmer, Markus A
2016-06-01
Although satisfactory outcomes have been reported after total knee replacement (TKR), full recovery of muscle strength and physical function is rare. We developed a relative activation index (RAI) to compare leg muscle activity from unnormalized surface electromyography (sEMG) between TKR and control subjects. Nineteen TKR and 19 control subjects underwent gait analysis and sEMG. RAIs were calculated by dividing the average sEMG for 2 consecutive subphases of stance defined by the direction of the external sagittal plane moment (flexion or extension). RAIs and external moments indicate TKR subjects have less initial stance antagonist rectus femoris activity (P = .004), greater middle stance antagonist biceps femoris activity (P < .001), and less late stance agonist biceps femoris activity (P < .001) than control subjects. Individuals with TKR demonstrate increased flexor muscle activation during weight bearing, potentially contributing to altered gait patterns found during the stance phase of gait. The RAI helps detail whether decreased external moments correspond to less agonist or more antagonist muscle activity to determine true muscle activity differences between subject groups. Identifying the mechanisms underlying altered muscle function both before and after TKR is critical for developing rehabilitation strategies to address functional deficits and disability found in this patient population. Copyright © 2015 Elsevier Inc. All rights reserved.
Jiang, Xi Zhuo; Feng, Muye; Ventikos, Yiannis; Luo, Kai H
2018-04-10
Flow patterns on surfaces grafted with complex structures play a pivotal role in many engineering and biomedical applications. In this research, large-scale molecular dynamics (MD) simulations are conducted to study the flow over complex surface structures of an endothelial glycocalyx layer. A detailed structure of glycocalyx has been adopted and the flow/glycocalyx system comprises about 5,800,000 atoms. Four cases involving varying external forces and modified glycocalyx configurations are constructed to reveal intricate fluid behaviour. Flow profiles including temporal evolutions and spatial distributions of velocity are illustrated. Moreover, streamline length and vorticity distributions under the four scenarios are compared and discussed to elucidate the effects of external forces and glycocalyx configurations on flow patterns. Results show that sugar chain configurations affect streamline length distributions but their impact on vorticity distributions is statistically insignificant, whilst the influence of the external forces on both streamline length and vorticity distributions are trivial. Finally, a regime diagram for flow over complex surface structures is proposed to categorise flow patterns.
In vitro tympanic membrane position identification with a co-axial fiber-optic otoscope
NASA Astrophysics Data System (ADS)
Sundberg, Mikael; Peebo, Markus; Strömberg, Tomas
2011-09-01
Otitis media diagnosis can be assisted by measuring the shape of the tympanic membrane. We have developed an ear speculum for an otoscope, including spatially distributed source and detector optical fibers, to generate source-detector intensity matrices (SDIMs), representing the curvature of surfaces. The surfaces measured were a model ear with a latex membrane and harvested temporal bones including intact tympanic membranes. The position of the tympanic membrane was shifted from retracted to bulging by air pressure and that of the latex membrane by water displacement. The SDIM was normalized utilizing both external (a sheared flat plastic cylinder) and internal references (neutral position of the membrane). Data was fitted to a two-dimensional Gaussian surface representing the shape by its amplitude and offset. Retracted and bulging surfaces were discriminated for the model ear by the sign of the Gaussian amplitude for both internal and external reference normalization. Tympanic membranes were separated after a two-step normalization: first to an external reference, adjusted for the distance between speculum and the surfaces, and second by comparison with an average normally positioned SDIM from tympanic membranes. In conclusion, we have shown that the modified otoscope can discriminate between bulging and retracted tympanic membranes in a single measurement, given a two-step normalization.
Wang, Shunzhi; McGuirk, C Michael; Ross, Michael B; Wang, Shuya; Chen, Pengcheng; Xing, Hang; Liu, Yuan; Mirkin, Chad A
2017-07-26
Metal-organic frameworks (MOFs) are a class of modular, crystalline, and porous materials that hold promise for storage and transport of chemical cargoes. Though MOFs have been studied in bulk forms, ways of deliberately manipulating the external surface functionality of MOF nanoparticles are less developed. A generalizable approach to modify their surfaces would allow one to impart chemical functionality onto the particle surface that is independent of the bulk MOF structure. Moreover, the use of a chemically programmable ligand, such as DNA, would allow for the manipulation of interparticle interactions. Herein, we report a coordination chemistry-based strategy for the surface functionalization of the external metal nodes of MOF nanoparticles with terminal phosphate-modified oligonucleotides. The external surfaces of nine distinct archetypical MOF particles containing four different metal species (Zr, Cr, Fe, and Al) were successfully functionalized with oligonucleotides, illustrating the generality of this strategy. By taking advantage of the programmable and specific interactions of DNA, 11 distinct MOF particle-inorganic particle core-satellite clusters were synthesized. In these hybrid nanoclusters, the relative stoichiometry, size, shape, and composition of the building blocks can all be independently controlled. This work provides access to a new set of nucleic acid-nanoparticle conjugates, which may be useful as programmable material building blocks and as probes for measuring and manipulating intracellular processes.
Walenkamp, Monique M J; Bentohami, Abdelali; Slaar, Annelie; Beerekamp, M S H Suzan; Maas, Mario; Jager, L C Cara; Sosef, Nico L; van Velde, Romuald; Ultee, Jan M; Steyerberg, Ewout W; Goslings, J C Carel; Schep, Niels W L
2016-01-01
Although only 39% of patients with wrist trauma have sustained a fracture, the majority of patients is routinely referred for radiography. The purpose of this study was to derive and externally validate a clinical decision rule that selects patients with acute wrist trauma in the Emergency Department (ED) for radiography. This multicenter prospective study consisted of three components: (1) derivation of a clinical prediction model for detecting wrist fractures in patients following wrist trauma; (2) external validation of this model; and (3) design of a clinical decision rule. The study was conducted in the EDs of five Dutch hospitals: one academic hospital (derivation cohort) and four regional hospitals (external validation cohort). We included all adult patients with acute wrist trauma. The main outcome was fracture of the wrist (distal radius, distal ulna or carpal bones) diagnosed on conventional X-rays. A total of 882 patients were analyzed; 487 in the derivation cohort and 395 in the validation cohort. We derived a clinical prediction model with eight variables: age; sex, swelling of the wrist; swelling of the anatomical snuffbox, visible deformation; distal radius tender to palpation; pain on radial deviation and painful axial compression of the thumb. The Area Under the Curve at external validation of this model was 0.81 (95% CI: 0.77-0.85). The sensitivity and specificity of the Amsterdam Wrist Rules (AWR) in the external validation cohort were 98% (95% CI: 95-99%) and 21% (95% CI: 15%-28). The negative predictive value was 90% (95% CI: 81-99%). The Amsterdam Wrist Rules is a clinical prediction rule with a high sensitivity and negative predictive value for fractures of the wrist. Although external validation showed low specificity and 100 % sensitivity could not be achieved, the Amsterdam Wrist Rules can provide physicians in the Emergency Department with a useful screening tool to select patients with acute wrist trauma for radiography. The upcoming implementation study will further reveal the impact of the Amsterdam Wrist Rules on the anticipated reduction of X-rays requested, missed fractures, Emergency Department waiting times and health care costs.
Rachmiel, Adi; Nseir, Saleh; Emodi, Omri; Aizenbud, Dror
2014-07-01
Obstructive sleep apnea is often associated with congenital craniofacial malformations due to hypoplastic mandible and decreased pharyngeal airway. In this study, we will compare external and internal distraction devices for mandibular lengthening in terms of effectiveness, results, patient comfort, and complications. Thirty-seven patients were treated by bilateral mandibular distraction osteogenesis for obstructive sleep apnea: 20 with external and 17 with internal distraction devices. Lengthening of the mandible and increase of the pharyngeal airway were obtained in all patients. Using the external devices, the average mandibular elongation was 30 mm versus 22 mm with the internal devices; however, after 1 year, the results were more stable with internal devices. External devices carried greater risk for pin tract infection than the internal devices (27.5% vs 5.88%). In addition, pin loosening in 22.5% required pin replacement or led to reduced retention period. Internal devices had a precise and predictable vector of lengthening and left less visible scars at the submandibular area but carried the disadvantage of requiring a second operation for device removal. In very young children with severe micrognathia, it was impossible to place internal devices, and external devices were used. Internal devices should be the first choice because they are more comfortable to the patients, more predictable vector of lengthening, are less vulnerable to dislodgement, and leave reduced scarring, with the great disadvantage of second operation for removal. However, external devices still should be considered mainly in severely hypoplastic cases, and the surgeon should be prepared for both options.
Multi-modal and targeted imaging improves automated mid-brain segmentation
NASA Astrophysics Data System (ADS)
Plassard, Andrew J.; D'Haese, Pierre F.; Pallavaram, Srivatsan; Newton, Allen T.; Claassen, Daniel O.; Dawant, Benoit M.; Landman, Bennett A.
2017-02-01
The basal ganglia and limbic system, particularly the thalamus, putamen, internal and external globus pallidus, substantia nigra, and sub-thalamic nucleus, comprise a clinically relevant signal network for Parkinson's disease. In order to manually trace these structures, a combination of high-resolution and specialized sequences at 7T are used, but it is not feasible to scan clinical patients in those scanners. Targeted imaging sequences at 3T such as F-GATIR, and other optimized inversion recovery sequences, have been presented which enhance contrast in a select group of these structures. In this work, we show that a series of atlases generated at 7T can be used to accurately segment these structures at 3T using a combination of standard and optimized imaging sequences, though no one approach provided the best result across all structures. In the thalamus and putamen, a median Dice coefficient over 0.88 and a mean surface distance less than 1.0mm was achieved using a combination of T1 and an optimized inversion recovery imaging sequences. In the internal and external globus pallidus a Dice over 0.75 and a mean surface distance less than 1.2mm was achieved using a combination of T1 and FGATIR imaging sequences. In the substantia nigra and sub-thalamic nucleus a Dice coefficient of over 0.6 and a mean surface distance of less than 1.0mm was achieved using the optimized inversion recovery imaging sequence. On average, using T1 and optimized inversion recovery together produced significantly improved segmentation results than any individual modality (p<0.05 wilcox sign-rank test).
Factors associated with external and internal lymphedema in patients with head-and-neck cancer.
Deng, Jie; Ridner, Sheila H; Dietrich, Mary S; Wells, Nancy; Wallston, Kenneth A; Sinard, Robert J; Cmelak, Anthony J; Murphy, Barbara A
2012-11-01
The purpose of this study was to examine factors associated with the presence of secondary external and internal lymphedema in patients with head-and-neck cancer (HNC). The sample included 81 patients ≥3 months after HNC treatment. Physical and endoscopic examinations were conducted to determine if participants had external, internal, and/or combined head-and-neck lymphedema. Logistic regression analysis was used to examine the factors associated with the presence of lymphedema. The following factors were statistically significantly associated with presence of lymphedema: (1) location of tumor associated with presence of external (P=.009) and combined lymphedema (P=.032); (2) time since end of HNC treatment associated with presence of external (P=.004) and combined lymphedema (P=.005); (3) total dosage of radiation therapy (P=.010) and days of radiation (P=.017) associated with the presence of combined lymphedema; (4) radiation status of surgical bed was associated with the presence of internal lymphedema, including surgery with postoperative radiation (P=.030) and (salvage) surgery in the irradiated field (P=.008); and (5) number of treatment modalities associated with external (P=.002), internal (P=.039), and combined lymphedema (P=.004). No demographic, health behavior-related, or comorbidity factors were associated with the presence of lymphedema in the sample. Select tumor and treatment parameters are associated with increased occurrence of lymphedema in patients with HNC. Larger and longitudinal studies are needed to identify adjusted effects and causative risk factors contributing to the development of lymphedema in patients with HNC. Copyright © 2012 Elsevier Inc. All rights reserved.
Using surface markers for MRI guided breast conserving surgery: a feasibility survey
NASA Astrophysics Data System (ADS)
Ebrahimi, Mehran; Siegler, Peter; Modhafar, Amen; Holloway, Claire M. B.; Plewes, Donald B.; Martel, Anne L.
2014-04-01
Breast MRI is frequently performed prior to breast conserving surgery in order to assess the location and extent of the lesion. Ideally, the surgeon should also be able to use the image information during surgery to guide the excision and this requires that the MR image is co-registered to conform to the patient’s position on the operating table. Recent progress in MR imaging techniques has made it possible to obtain high quality images of the patient in the supine position which significantly reduces the complexity of the registration task. Surface markers placed on the breast during imaging can be located during surgery using an external tracking device and this information can be used to co-register the images to the patient. There remains the problem that in most clinical MR scanners the arm of the patient has to be placed parallel to the body whereas the arm is placed perpendicular to the patient during surgery. The aim of this study is to determine the accuracy of co-registration based on a surface marker approach and, in particular, to determine what effect the difference in a patient’s arm position makes on the accuracy of tumour localization. Obtaining a second MRI of the patient where the patient’s arm is perpendicular to body axes (operating room position) is not possible. Instead we obtain a secondary MRI scan where the patient’s arm is above the patient’s head to validate the registration. Five patients with enhancing lesions ranging from 1.5 to 80 cm3 in size were imaged using contrast enhanced MRI with their arms in two positions. A thin-plate spline registration scheme was used to match these two configurations. The registration algorithm uses the surface markers only and does not employ the image intensities. Tumour outlines were segmented and centre of mass (COM) displacement and Dice measures of lesion overlap were calculated. The relationship between the number of markers used and the COM-displacement was also studied. The lesion COM-displacements ranged from 0.9 to 9.3 mm and the Dice overlap score ranged from 20% to 80%. The registration procedure took less than 1 min to run on a standard PC. Alignment of pre-surgical supine MR images to the patient using surface markers on the breast for co-registration therefore appears to be feasible.
Kulkarni, Ruta; Singh, Nishant; Kulkarni, Govind S; Kulkarni, Milind; Kulkarni, Sunil; Kulkarni, Vidisha
2012-01-01
Background: The limb lengthening over plate eliminates the associated risk of infection with limb lengthening over intramedullary nail. We present our experience of limb lengthening in 15 patients with a plate fixed on the proximal segment, followed by corticotomy and application of external fixator. Materials and Methods: 15 patients (7 females, 8 males) were included in this consecutive series. The average age was 18.1 years (range 8–35 years). Fifteen tibiae and one femur were lengthened in 15 patients. Lengthening was achieved at 1 mm/day followed by distal segment fixation with three or four screws on reaching the target length. Results: The preoperative target length was successfully achieved in all patients at a mean of 4.1 cm (range 1.8–6.5 cm). The mean duration of external fixation was 75.3 days (range 33–116 days) with the mean external fixation index at 19.2 days/cm (range 10.0–38.3 days/cm). One patient suffered deep infection up to the plate, three patients had mild procurvatum deformities, and one patient developed mild tendo achilles contracture. Conclusion: Lengthening over a plate allows early removal of external fixator and eliminates the risk of creating deep intramedullary infection as with lengthening over nail. Lengthening over plate is also applicable to children with open physis. PMID:22719123
Limb lengthening over a nail can safely reduce the duration of external fixation
Chaudhary, Milind
2008-01-01
Background: Limb lengthening using Ilizarov external fixation is safe, but the consolidation phase tends to take too long. A method that can safely reduce the time spent in external fixation would help increase patient tolerance and comfort. We report our results of lengthening over nails (LON) method in which an interlocking nail was used along with an Ilizarov external fixator to reduce external fixation duration in limb lengthening. This is a retrospective study. Materials and Methods: Twenty-seven lengthening surgeries were done with the LON method in 23 patients with 22 tibiae and five femora during the last 12 years. Length gain ranged from 1.5 cm to a maximum of 9.8 cm with a mean of 4.6 cm. The mean modified Paley difficulty score was 7.6 points. Fourteen associated procedures were performed in these patients, including equinus contracture releases, supracondylar osteotomies, ilizarov hip reonstruction and ankle fusion. We had a 29% rate of complications which included one problem, three obstacles and four complications with no serious deep intramedullary infections. Our rate of complications compares favorably with series reported in the literature. External fixation duration was reduced significantly to a mean of 17.8 days per cm. Conclusions: A combination of intramedullary nailing along with external fixation significantly reduces external fixation time while maintaining low rate of complications. Great care needs to be taken to prevent pin track infection and deep intramedullary sepsis. PMID:19753160
[Bacteriological evaluation of a procedure for disinfecting the Olympus GIF-D2 panendoscope].
Ramírez Ramos, A; Domínguez, N; Makino, R; Barrera, C
1980-01-01
We have performed a total of 107 cultures from three critical areas of an Olympus Panendoscope Model GIF-D2 in order to evaluate bacteriologically cur system of desinfection of this endoscope. Samples were taken from the distal end, external surface and biopsy canal before and after an endoscopic examination was performed. The procedure of desinfection employed was as follows: washing of the distal end, external surface and biopsy canal with Hexaclorophel (Phisohex) diluted 50% with water and a second washing with tap water. In the middle of the study, we added a second washing of the biopsy canal with ten ml. of ether alcohol to allow for better drying. As a result of the present study we observed that in the distal end in 50% of the samples we encountered bacteria. Cultures of the external surface were positive in 20% of samples. The biopsy canal should be washed with ether alcohol to allow for complete drying, because when we did not use this method, Pseudomonas Aeruginosa was isolated. After this modification we did not isolate bacteria. The most frequent types of isolated bacteria were from the normal oropharyngeal flora. From the present study we can conclude that desinfection of the Panendespe with Hexaclorophen gives satisfactory results on the external surface of the endoscope. Biopsy canal requires additional washing with ether alcohol. However, both procedures do not assure a satisfactory desinfection of the distal end.
Ii, Noriko; Fuwa, Nobukazu; Toyomasu, Yutaka; Takada, Akinori; Nomura, Miwako; Kawamura, Tomoko; Sakuma, Hajime; Nomoto, Yoshihito
2017-07-01
The purpose of this study was to describe a novel system for treating advanced head and neck cancer consisting of an external carotid arterial sheath (ECAS) and a microcatheter to inject drugs retrogradely into multiple feeding arteries through the superficial temporal artery (STA). Four consecutive patients with head and neck cancer that had more than one feeding artery were enrolled in this study. The ECAS was made of polyurethane and surface-coated with heparin resin to prevent thrombus formation, allowing it to remain in place for a prolonged period of time. The ECAS was inserted through the STA, and its tip was placed between the maxillary artery and facial artery. The tumor-feeding arteries were selected using a hooked-shaped microcatheter through the ECAS. A total of 13 target arteries were selected in the four patients. The microcatheter inserted via the ECAS was used to catheterize ten arteries (five lingual arteries and five facial arteries). The remaining three lingual arteries were directly selected by the catheter without ECAS. All of the target arteries were able to be catheterized superselectively. The technical success rate was 100%. Vascular occlusion, which might have been caused by the ECAS, was observed in one patient. No neurologic toxicities occurred. This ECAS system is a new approach for retrograde superselective intra-arterial chemotherapy that covers the entire tumor with anticancer drugs. It has the potential to increase the effectiveness of therapy for advanced head and neck cancer. Level 4, Case Series.
Response of lower genital tract flora to external pelvic irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, A.N.; Martens, M.; LaPread, Y.
1989-11-01
Endocervical and vaginal cultures were obtained every week from patients undergoing external pelvic irradiation for gynecologic malignancy. Gram-positive aerobes accounted for 52 to 56% of isolates, gram-negative aerobes accounted for 15 to 16%, and anaerobes accounted for 29 to 32% of all isolates prior to therapy. No significant changes occurred during or after completion of radiation for the group. In individual patients, however, over 50% of organisms found on initial culture were no longer present on completion of external therapy.
49 CFR 192.483 - Remedial measures: General.
Code of Federal Regulations, 2011 CFR
2011-10-01
... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control... a buried or submerged pipeline because of external corrosion must have a properly prepared surface... external corrosion must be cathodically protected in accordance with this subpart. (c) Except for cast iron...
49 CFR 192.483 - Remedial measures: General.
Code of Federal Regulations, 2010 CFR
2010-10-01
... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control... a buried or submerged pipeline because of external corrosion must have a properly prepared surface... external corrosion must be cathodically protected in accordance with this subpart. (c) Except for cast iron...
49 CFR 192.483 - Remedial measures: General.
Code of Federal Regulations, 2014 CFR
2014-10-01
... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control... a buried or submerged pipeline because of external corrosion must have a properly prepared surface... external corrosion must be cathodically protected in accordance with this subpart. (c) Except for cast iron...
49 CFR 192.483 - Remedial measures: General.
Code of Federal Regulations, 2012 CFR
2012-10-01
... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control... a buried or submerged pipeline because of external corrosion must have a properly prepared surface... external corrosion must be cathodically protected in accordance with this subpart. (c) Except for cast iron...
49 CFR 192.483 - Remedial measures: General.
Code of Federal Regulations, 2013 CFR
2013-10-01
... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control... a buried or submerged pipeline because of external corrosion must have a properly prepared surface... external corrosion must be cathodically protected in accordance with this subpart. (c) Except for cast iron...
Wang, Jia; Zhang, Yun-Tong; Zhang, Chun-Cai; Tang, Yang
2014-01-01
To analyze causes of missed diagnosis of hiding post-malleolar fractures in treating ankle joint fractures of pronation-external rotation type according to Lauge-Hansen classification and assess its medium-term outcomes. Among 103 patients with ankle joint fracture of pronation-external rotation type treated from March 2002 to June 2010,9 patients were missed diagnosis,including 6 males and 3 females,with a mean age of 35.2 years old (ranged, 18 to 55 years old) . Four patients were diagnosed during operation, 2 patients were diagnosed 2 or 3 days after first surgery and 3 patients came from other hospital. All the patients were treated remedially with lag screws and lock plates internal fixation. After operation,ankle joint function was evaluated according to American Orthopaedic Foot and Ankle Society (AOFAS). All the 9 patients were followed up, and the duration ranged from 14 to 30 months (averaged, 17 months). No incision infection was found, and all incision healed at the first stage. At the latest follow-up, AOFAS was 83.0 +/- 4.4, the score of 4 patients diagnosed during operation was 85.0 +/- 2.9, and the score of 5 patients treated by secondary operation was 81.0 +/- 5.3. All the patients got fracture union observed by X-ray at a mean time of 2.2 months after operation. There were no complications such as internal fixation loosing, broken and vascular or nerve injuries. Ankle joint fracture of pronation-external rotation type may be combined with hiding post-malleolar fractures. So to patients with ankle joint fracture of pronation-external rotation type, lateral X-ray should be read carefully, and if necessary, CT or MRI examination should be performed. If adding lateral X-ray examination after reduction of exterior and interior ankle joint fixation, the missed diagnosis may be avoided.
Importation, Mitigation, and Genomic Epidemiology of Candida auris at a Large Teaching Hospital.
Lesho, Emil P; Bronstein, Melissa Z; McGann, Patrick; Stam, Jason; Kwak, Yoon; Maybank, Rosslyn; McNamara, Jodi; Callahan, Megan; Campbell, Jean; Hinkle, Mary K; Walsh, Edward E
2018-01-01
OBJECTIVE Candida auris (CA) is an emerging multidrug-resistant pathogen associated with increased mortality. The environment may play a role, but transmission dynamics remain poorly understood. We sought to limit environmental and patient CA contamination following a sustained unsuspected exposure. DESIGN Quasi-experimental observation. SETTING A 528-bed teaching hospital. PATIENTS The index case patient and 17 collocated ward mates. INTERVENTION Immediately after confirmation of CA in the bloodstream and urine of a patient admitted 6 days previously, active surveillance, enhanced transmission-based precautions, environmental cleaning with peracetic acid-hydrogen peroxide and ultraviolet light, and patient relocation were undertaken. Pre-existing agreements and foundational relationships among internal multidisciplinary teams and external partners were leveraged to bolster detection and mitigation efforts and to provide genomic epidemiology. RESULTS Candida auris was isolated from 3 of 132 surface samples on days 8, 9, and 15 of ward occupancy, and from no patient samples (0 of 48). Environmental and patient isolates were genetically identical (4-8 single-nucleotide polymorphisms [SNPs]) and most closely related to the 2013 India CA-6684 strain (~200 SNPs), supporting the epidemiological hypothesis that the source of environmental contamination was the index case patient, who probably acquired the South Asian strain from another New York hospital. All isolates contained a mutation associated with azole resistance (K163R) found in the India 2105 VPCI strain but not in CA-6684. The index patient remained colonized until death. No surfaces were CA-positive 1 month later. CONCLUSION Compared to previous descriptions, CA dissemination was minimal. Immediate access to rapid CA diagnostics facilitates early containment strategies and outbreak investigations. Infect Control Hosp Epidemiol 2018;39:53-57.
Spatial and rotational quality assurance of 6DOF patient tracking systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belcher, Andrew H.; Liu, Xinmin; Grelewicz, Zachary
Purpose: External tracking systems used for patient positioning and motion monitoring during radiotherapy are now capable of detecting both translations and rotations. In this work, the authors develop a novel technique to evaluate the 6 degree of freedom 6(DOF) (translations and rotations) performance of external motion tracking systems. The authors apply this methodology to an infrared marker tracking system and two 3D optical surface mapping systems in a common tumor 6DOF workspace. Methods: An in-house designed and built 6DOF parallel kinematics robotic motion phantom was used to perform motions with sub-millimeter and subdegree accuracy in a 6DOF workspace. An infraredmore » marker tracking system was first used to validate a calibration algorithm which associates the motion phantom coordinate frame to the camera frame. The 6DOF positions of the mobile robotic system in this space were then tracked and recorded independently by an optical surface tracking system after a cranial phantom was rigidly fixed to the moveable platform of the robotic stage. The calibration methodology was first employed, followed by a comprehensive 6DOF trajectory evaluation, which spanned a full range of positions and orientations in a 20 × 20 × 16 mm and 5° × 5° × 5° workspace. The intended input motions were compared to the calibrated 6DOF measured points. Results: The technique found the accuracy of the infrared (IR) marker tracking system to have maximal root-mean square error (RMSE) values of 0.18, 0.25, 0.07 mm, 0.05°, 0.05°, and 0.09° in left–right (LR), superior–inferior (SI), anterior–posterior (AP), pitch, roll, and yaw, respectively, comparing the intended 6DOF position and the measured position by the IR camera. Similarly, the 6DOF RSME discrepancy for the HD optical surface tracker yielded maximal values of 0.46, 0.60, 0.54 mm, 0.06°, 0.11°, and 0.08° in LR, SI, AP, pitch, roll, and yaw, respectively, over the same 6DOF evaluative workspace. An earlier generation 3D optical surface tracking unit was observed to have worse tracking capabilities than both the IR camera unit and the newer 3D surface tracking system with maximal RMSE of 0.69, 0.74, 0.47 mm, 0.28°, 0.19°, and 0.18°, in LR, SI, AP, pitch, roll, and yaw, respectively, in the same 6DOF evaluation space. Conclusions: The proposed technique was found to be effective at evaluating the performance of 6DOF patient tracking systems. All observed optical tracking systems were found to exhibit tracking capabilities at the sub-millimeter and subdegree level within a 6DOF workspace.« less
Lee, Dong-Kyu; Kim, Se-Hun
2018-05-01
[Purpose] This study aims to identify the effect of respiratory exercise on trunk control, pulmonary function, and trunk muscle activity in chronic stroke patients. [Subjects and Methods] The study included 24 chronic stroke patients who were randomly assigned, 12 each, to the experimental and control groups, and received neurodevelopmental treatment. Moreover, the experimental group underwent respiratory exercise. In each patient, the trunk control was measured using the Trunk Impairment Scale (TIS); muscle activity of the trunk, through the surface electromyogram; and pulmonary function, using the pneumatometer. [Results] The intragroup comparison showed significant differences in TIS, Forced vital capacity (FVC), Forced expiratory volume at one second (FEV1), Rectus Abdominis (RA), Internal Oblique (IO) and External Oblique (EO) in the experimental group. The intergroup comparison showed that the differences in TIS, FVC, FEV1, RA, IO and EO within the experimental group appeared significant relative to the control group. [Conclusion] Based on these results, this study proved that respiratory exercise was effective in improving trunk control, pulmonary function, and trunk muscle activity in patients with chronic stroke.
Impact Melt Emplacement on Mercury
NASA Astrophysics Data System (ADS)
Daniels, J. W.; Neish, C. D.
2018-05-01
This work proposes that fresh craters on rocky bodies may deposit impact melt externally ultimately according to the strength of its surface gravity, regardless of the body's surface topography and melt abundance.
Thermophysical fundamentals of cyclonic recirculating heating devices
NASA Astrophysics Data System (ADS)
Karpov, S. V.; Zagoskin, A. A.
2017-10-01
This report presents the results of experimental and theoretical research of aerodynamics and convective heat transfer in cyclone devices with the new system of external recirculation of heating gas under the influence of radial pressure gradient in a heat carrier’s swirling turbulent flow. The dynamic problem of tangential velocity distribution in a clearance volume is solved at various re-circulation ratio values including limiting quantities (kr = 0; 1) and variations in cyclonic combustion chamber’s design parameters and operating conditions (Rer); the integrated calculation ratios for fundamental aerodynamic characteristics of a recirculation device are derived. The first experimental and numerical studies of convective heat transfer on internal and external surfaces of a hollow shaft in a swirling recirculation flow are derived through the instrumentality of OpenFOAM, these studies are also conducted for a setting of several cylindrical solid inserts. The external surface heat problem of a hollow cylindrical insert is solved with integral and digital methods; generalized similarity equations for the internal and external surfaces extended in range of Reynolds number are derived. The experimental data is in reasonable agreement with the derived curves and the results of mathematic modelling of convective heat transfer. Calculation recommendations for optimal selection of kr values at various ratios of their geometric characteristics and products utilization rate are obtained.
External Surface Changes Observed on the International Space Station (ISS) Through 2012
NASA Technical Reports Server (NTRS)
Golden, Johnny L.
2012-01-01
As the International Space Station (ISS) surpasses 13 years of on-orbit operation, 11 of those years continuously inhabited, external surfaces of the vehicle have shown a wide variety of visible environmental effects. Throughout, the ISS program has maintained a significant effort to routinely document the vehicle external surface condition and to monitor those changes with time. The impacts of micrometeoroids and orbital debris, surface changes from molecular contamination of various sources, and the effects of ultraviolet radiation and atomic oxygen have all been noted. The tremendous size and complexity of the ISS vehicle has yielded a wide variety of observations of interest to the spacecraft materials engineer concerning long-term, low earth orbit (LEO) space environmental effects (SEE). In addition, inadvertent materials substitutions have been identified because of these environmental effects, as well as inadequate contamination control practices likely occurring during hardware manufacture and assembly. Some of the observations from our photography are purely artifacts of the unusual lighting conditions and environments that exist in space. A compilation of ISS on-orbit photography representing all of these aspects is presented, demonstrating the various SEE and their impacts as a function of time in LEO, including interpretations of those effects.
The Footprint of the Inter-decadal Pacific Oscillation in Indian Ocean Sea Surface Temperatures
NASA Astrophysics Data System (ADS)
Dong, Lu; Zhou, Tianjun; Dai, Aiguo; Song, Fengfei; Wu, Bo; Chen, Xiaolong
2016-02-01
Superimposed on a pronounced warming trend, the Indian Ocean (IO) sea surface temperatures (SSTs) also show considerable decadal variations that can cause regional climate oscillations around the IO. However, the mechanisms of the IO decadal variability remain unclear. Here we perform numerical experiments using a state-of-the-art, fully coupled climate model in which the external forcings with or without the observed SSTs in the tropical eastern Pacific Ocean (TEP) are applied for 1871-2012. Both the observed timing and magnitude of the IO decadal variations are well reproduced in those experiments with the TEP SSTs prescribed to observations. Although the external forcings account for most of the warming trend, the decadal variability in IO SSTs is dominated by internal variability that is induced by the TEP SSTs, especially the Inter-decadal Pacific Oscillation (IPO). The IPO weakens (enhances) the warming of the external forcings by about 50% over the IO during IPO’s cold (warm) phase, which contributes about 10% to the recent global warming hiatus since 1999. The decadal variability in IO SSTs is modulated by the IPO-induced atmospheric adjustment through changing surface heat fluxes, sea surface height and thermocline depth.
The Footprint of the Inter-decadal Pacific Oscillation in Indian Ocean Sea Surface Temperatures.
Dong, Lu; Zhou, Tianjun; Dai, Aiguo; Song, Fengfei; Wu, Bo; Chen, Xiaolong
2016-02-17
Superimposed on a pronounced warming trend, the Indian Ocean (IO) sea surface temperatures (SSTs) also show considerable decadal variations that can cause regional climate oscillations around the IO. However, the mechanisms of the IO decadal variability remain unclear. Here we perform numerical experiments using a state-of-the-art, fully coupled climate model in which the external forcings with or without the observed SSTs in the tropical eastern Pacific Ocean (TEP) are applied for 1871-2012. Both the observed timing and magnitude of the IO decadal variations are well reproduced in those experiments with the TEP SSTs prescribed to observations. Although the external forcings account for most of the warming trend, the decadal variability in IO SSTs is dominated by internal variability that is induced by the TEP SSTs, especially the Inter-decadal Pacific Oscillation (IPO). The IPO weakens (enhances) the warming of the external forcings by about 50% over the IO during IPO's cold (warm) phase, which contributes about 10% to the recent global warming hiatus since 1999. The decadal variability in IO SSTs is modulated by the IPO-induced atmospheric adjustment through changing surface heat fluxes, sea surface height and thermocline depth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, X.; Cianciosa, M. R.; Ennis, D. A.
In this research, collimated soft X-ray (SXR) emissivity measurements from multi-channel cameras on the Compact Toroidal Hybrid (CTH) tokamak/torsatron device are incorporated in the 3D equilibrium reconstruction code V3FIT to reconstruct the shape of flux surfaces and infer the current distribution within the plasma. Equilibrium reconstructions of sawtoothing plasmas that use data from both SXR and external magnetic diagnostics show the central safety factor to be near unity under the assumption that SXR iso-emissivity contours lie on magnetic flux surfaces. The reconstruction results are consistent with those using the external magnetic data and a constraint on the location of qmore » = 1 surfaces determined from the sawtooth inversion surface extracted from SXR brightness profiles. The agreement justifies the use of approximating SXR emission as a flux function in CTH, at least within the core of the plasma, subject to the spatial resolution of the SXR diagnostics. Lastly, this improved reconstruction of the central current density indicates that the current profile peakedness decreases with increasing external transform and that the internal inductance is not a relevant measure of how peaked the current profile is in hybrid discharges.« less
Steady state model for the thermal regimes of shells of airships and hot air balloons
NASA Astrophysics Data System (ADS)
Luchev, Oleg A.
1992-10-01
A steady state model of the temperature regime of airships and hot air balloons shells is developed. The model includes three governing equations: the equation of the temperature field of airships or balloons shell, the integral equation for the radiative fluxes on the internal surface of the shell, and the integral equation for the natural convective heat exchange between the shell and the internal gas. In the model the following radiative fluxes on the shell external surface are considered: the direct and the earth reflected solar radiation, the diffuse solar radiation, the infrared radiation of the earth surface and that of the atmosphere. For the calculations of the infrared external radiation the model of the plane layer of the atmosphere is used. The convective heat transfer on the external surface of the shell is considered for the cases of the forced and the natural convection. To solve the mentioned set of the equations the numerical iterative procedure is developed. The model and the numerical procedure are used for the simulation study of the temperature fields of an airship shell under the forced and the natural convective heat transfer.
Surface morphology of taste buds in catfish barbels.
Ovalle, W K; Shinn, S L
1977-03-16
External taste buds abound on barbels of the adult catfish Corydoras arcuatus. When examined by scanning electron microscopy, they are visualized as a series of punctate, conical elevations projecting from the general surface epithelium. All taste buds were found to be of one type. Both their external and internal surface features could be clearly elucidated on intact barbels and in barbels fractured transversely at various positions along their length. An extensive nerve terminal network penetrates the base of each taste bud. Two populations of elongated cells bearing prominent microvilli project through the central pore at the tip of each bud. One set of microvilli is thicker, longer and more club-shaped than its counterpart. While both are randomly distributed within each central pore, the small, short microvilli appear to outnumber the larger ones. A third population of cells, devoid of any apical microvilli, was also seen in some of the taste buds examined internally. These cells do not project to the external surface and are interpreted as "basal" cells described in previous light and transmission electron microscope studies of taste buds in other vertebrate species. The functional significance of some of these morphological findings is discussed.
NASA Astrophysics Data System (ADS)
Ma, X.; Cianciosa, M. R.; Ennis, D. A.; Hanson, J. D.; Hartwell, G. J.; Herfindal, J. L.; Howell, E. C.; Knowlton, S. F.; Maurer, D. A.; Traverso, P. J.
2018-01-01
Collimated soft X-ray (SXR) emissivity measurements from multi-channel cameras on the Compact Toroidal Hybrid (CTH) tokamak/torsatron device are incorporated in the 3D equilibrium reconstruction code V3FIT to reconstruct the shape of flux surfaces and infer the current distribution within the plasma. Equilibrium reconstructions of sawtoothing plasmas that use data from both SXR and external magnetic diagnostics show the central safety factor to be near unity under the assumption that SXR iso-emissivity contours lie on magnetic flux surfaces. The reconstruction results are consistent with those using the external magnetic data and a constraint on the location of q = 1 surfaces determined from the sawtooth inversion surface extracted from SXR brightness profiles. The agreement justifies the use of approximating SXR emission as a flux function in CTH, at least within the core of the plasma, subject to the spatial resolution of the SXR diagnostics. This improved reconstruction of the central current density indicates that the current profile peakedness decreases with increasing external transform and that the internal inductance is not a relevant measure of how peaked the current profile is in hybrid discharges.
Ma, X.; Cianciosa, M. R.; Ennis, D. A.; ...
2018-01-31
In this research, collimated soft X-ray (SXR) emissivity measurements from multi-channel cameras on the Compact Toroidal Hybrid (CTH) tokamak/torsatron device are incorporated in the 3D equilibrium reconstruction code V3FIT to reconstruct the shape of flux surfaces and infer the current distribution within the plasma. Equilibrium reconstructions of sawtoothing plasmas that use data from both SXR and external magnetic diagnostics show the central safety factor to be near unity under the assumption that SXR iso-emissivity contours lie on magnetic flux surfaces. The reconstruction results are consistent with those using the external magnetic data and a constraint on the location of qmore » = 1 surfaces determined from the sawtooth inversion surface extracted from SXR brightness profiles. The agreement justifies the use of approximating SXR emission as a flux function in CTH, at least within the core of the plasma, subject to the spatial resolution of the SXR diagnostics. Lastly, this improved reconstruction of the central current density indicates that the current profile peakedness decreases with increasing external transform and that the internal inductance is not a relevant measure of how peaked the current profile is in hybrid discharges.« less
Ari, Seyhmus; Kürşat Cingü, Abdullah; Sahin, Alparslan; Gün, Ramazan; Kiniş, Vefa; Caça, Ihsan
2012-01-01
To evaluate the long-term treatment outcomes in patients who underwent revision of external dacryocystorhinostomy (DCR) and nasal intubation by bicanalicular silicone tubing (BSTI) under endonasal endoscopic guidance. Data from 28 patients with recurrent dacryocystitis were retrospectively reviewed. Revision external DCR and bicanalicular nasal intubation by silicone tubing under endonasal endoscopic guidance was performed in 28 eyes of 28 patients. The patients were evaluated with respect to the reason of recurrence, time to recurrence, time to revision, duration of follow-up and surgical success. Endoscopic endonasal examination detected an osteotomy-side obstruction by the excessive granulation tissue in 24 patients (86%), nasal septal deviation in three patients (10%) and nasal polyp in one patient (4%). Recurrence occurred after a mean duration of 5.3±3.7 months following the first operation. The mean time between the first DCR operation and the revision DCR was 11.5 ± 9.3 months. After a mean follow-up of 14.9±7.8 months, the rate of anatomic success alone was 85% (24/28); the rate of subjective success was 78% (22/28). Revision external DCR and bicanalicular nasal intubation by silicone tubing under endonasal endoscopic guidance can be recommended in patients with recurrent dacryocystitis as a surgical approach that achieves satisfactory objective and subjective success rates.
Ari, Şeyhmus; Kürşat Cingü, Abdullah; Şahin, Alparslan; Gün, Ramazan; Kiniş, Vefa; Çaça, İhsan
2012-01-01
AIM To evaluate the long-term treatment outcomes in patients who underwent revision of external dacryocystorhinostomy (DCR) and nasal intubation by bicanalicular silicone tubing (BSTI) under endonasal endoscopic guidance. METHODS Data from 28 patients with recurrent dacryocystitis were retrospectively reviewed. Revision external DCR and bicanalicular nasal intubation by silicone tubing under endonasal endoscopic guidance was performed in 28 eyes of 28 patients. The patients were evaluated with respect to the reason of recurrence, time to recurrence, time to revision, duration of follow-up and surgical success. RESULTS Endoscopic endonasal examination detected an osteotomy-side obstruction by the excessive granulation tissue in 24 patients (86%), nasal septal deviation in three patients (10%) and nasal polyp in one patient (4%). Recurrence occurred after a mean duration of 5.3±3.7 months following the first operation. The mean time between the first DCR operation and the revision DCR was 11.5 ± 9.3 months. After a mean follow-up of 14.9±7.8 months, the rate of anatomic success alone was 85% (24/28); the rate of subjective success was 78% (22/28). CONCLUSION Revision external DCR and bicanalicular nasal intubation by silicone tubing under endonasal endoscopic guidance can be recommended in patients with recurrent dacryocystitis as a surgical approach that achieves satisfactory objective and subjective success rates. PMID:22762058
Clinical technique for invasive cervical root resorption
Silveira, Luiz Fernando Machado; Silveira, Carina Folgearini; Martos, Josué; Piovesan, Edno Moacir; César Neto, João Batista
2011-01-01
This clinical case report describes the diagnosis and treatment of an external invasive cervical resorption. A 17-year-old female patient had a confirmed diagnosis of invasive cervical resorption class 4 by cone beam computerized tomography. Although, there was no communication with the root canal, the invasive resorption process was extending into the cervical and middle third of the root. The treatment of the cervical resorption of the lateral incisor interrupted the resorptive process and restored the damaged root surface and the dental functions without any esthetic sequelae. Both the radiographic examination and computed tomography are imperative to reveal the extent of the defect in the differential diagnosis. PMID:22144822
ARM-based visual processing system for prosthetic vision.
Matteucci, Paul B; Byrnes-Preston, Philip; Chen, Spencer C; Lovell, Nigel H; Suaning, Gregg J
2011-01-01
A growing number of prosthetic devices have been shown to provide visual perception to the profoundly blind through electrical neural stimulation. These first-generation devices offer promising outcomes to those affected by degenerative disorders such as retinitis pigmentosa. Although prosthetic approaches vary in their placement of the stimulating array (visual cortex, optic-nerve, epi-retinal surface, sub-retinal surface, supra-choroidal space, etc.), most of the solutions incorporate an externally-worn device to acquire and process video to provide the implant with instructions on how to deliver electrical stimulation to the patient, in order to elicit phosphenized vision. With the significant increase in availability and performance of low power-consumption smart phone and personal device processors, the authors investigated the use of a commercially available ARM (Advanced RISC Machine) device as an externally-worn processing unit for a prosthetic neural stimulator for the retina. A 400 MHz Samsung S3C2440A ARM920T single-board computer was programmed to extract 98 values from a 1.3 Megapixel OV9650 CMOS camera using impulse, regional averaging and Gaussian sampling algorithms. Power consumption and speed of video processing were compared to results obtained to similar reported devices. The results show that by using code optimization, the system is capable of driving a 98 channel implantable device for the restoration of visual percepts to the blind.
Annular Internal-External-Expansion Rocket Nozzles for Large Booster Applications
NASA Technical Reports Server (NTRS)
Connors, James F.; Cubbison, Robert W.; Mitchell, Glenn A.
1961-01-01
For large-thrust booster applications, annular rocket nozzles employing both internal and external expansion are investigated. In these nozzles, free-stream air flows through the center as well as around the outside of the exiting jet. Flaps for deflecting the rocket exhaust are incorporated on the external-expansion surface for thrust-vector control. In order to define nozzle off-design performance, thrust vectoring effectiveness, and external stream effects, an experimental investigation was conducted on two annular nozzles with area ratios of 15 and 25 at Mach 0, 2, and 3 in the Lewis 10- by 10-foot wind tunnel. Air, pressurized to 600 pounds per square inch absolute, was used to simulate the exhaust flow. For a nozzle-pressure-ratio range of 40 to 1000, the ratio of actual to ideal thrust was essentially constant at 0.98 for both nozzles. Compared with conventional convergent-divergent configurations on hypothetical boost missions, the performance gains of the annular nozzle could yield significant orbital payload increases (possibly 8 to 17 percent). A single flap on the external-expansion surface of the area-ratio-25 annular nozzle produced a side force equal to 4 percent of the axial force with no measurable loss in axial thrust.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Derakhshani, Kamran, E-mail: kderakhshani@iasbs.ac.ir
2014-03-01
In this paper, we investigate the external field effect in the context of the MOdified Newtonian Dynamics (MOND) on the surface brightness and velocity dispersion profiles of globular clusters (GCs). Using N-MODY, which is an N-body simulation code with a MOND potential solver, we show that the general effect of the external field for diffuse clusters, which obey MOND in most of their parts, is that it pushes the dynamics toward the Newtonian regime. On the other hand, for more compact clusters, which are essentially Newtonian in their inner parts, the external field is effective mainly in the outer partsmore » of compact clusters. As a case study, we then choose the remote Galactic GC NGC 2419. By varying the cluster mass, half-light radius, and mass-to-light ratio, we aim to find a model that will reproduce the observational data most effectively, using N-MODY. We find that even if we take the Galactic external field into account, a Newtonian Plummer sphere represents the observational data better than MOND to an order of magnitude in terms of the total χ{sup 2} of surface brightness and velocity dispersion.« less
NASA Astrophysics Data System (ADS)
Derakhshani, Kamran
2014-03-01
In this paper, we investigate the external field effect in the context of the MOdified Newtonian Dynamics (MOND) on the surface brightness and velocity dispersion profiles of globular clusters (GCs). Using N-MODY, which is an N-body simulation code with a MOND potential solver, we show that the general effect of the external field for diffuse clusters, which obey MOND in most of their parts, is that it pushes the dynamics toward the Newtonian regime. On the other hand, for more compact clusters, which are essentially Newtonian in their inner parts, the external field is effective mainly in the outer parts of compact clusters. As a case study, we then choose the remote Galactic GC NGC 2419. By varying the cluster mass, half-light radius, and mass-to-light ratio, we aim to find a model that will reproduce the observational data most effectively, using N-MODY. We find that even if we take the Galactic external field into account, a Newtonian Plummer sphere represents the observational data better than MOND to an order of magnitude in terms of the total χ2 of surface brightness and velocity dispersion.
2010-01-01
Although there is a clear trend toward internal fixation for ankle arthrodesis, there is general consensus that external fixation is required for cases of posttraumatic infection. We retrospectively evaluated the technique and clinical long term results of external fixation in a triangular frame for cases of posttraumatic infection of the ankle. From 1993 to 2006 a consecutive series of 155 patients with an infection of the ankle was included in our study. 133 cases of the advanced "Gächter" stage III and IV were treated with arthrodesis. We treated the patients with a two step treatment plan. After radical debridement and sequestrectomy the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted in the tibia and in the calcaneus and the gap was temporary filled with gentamicin beads as the first step. In the second step we performed an autologous bone graft after a period of four weeks. The case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues. Mean age at the index procedure was 49.7 years (18-82), 104 patients were male (67,1%). Follow up examination after mean 4.5 years included a standardised questionnaire and a clinical examination including the criteria of the AO-FAS-Score and radiographs. 92,7% of the cases lead to a stable arthrodesis. In 5 patients the arthrodesis was found partly-stable. In six patients (4,5%) the infection was not controllable during the treatment process. These patients had to be treated with a below knee amputation. The mean AOFAS score at follow up was 63,7 (53-92). Overall there is a high degree of remaining disability. The complication rate and the reduced patient comfort reserve this method mainly for infection. Joint salvage is possible in the majority of cases with an earlier stage I and II infection. PMID:20452884
Kienast, Benjamin; Kiene, J; Gille, J; Thietje, R; Gerlach, U; Schulz, A P
2010-02-26
Although there is a clear trend toward internal fixation for ankle arthrodesis, there is general consensus that external fixation is required for cases of posttraumatic infection. We retrospectively evaluated the technique and clinical long term results of external fixation in a triangular frame for cases of posttraumatic infection of the ankle. From 1993 to 2006 a consecutive series of 155 patients with an infection of the ankle was included in our study. 133 cases of the advanced "Gächter" stage III and IV were treated with arthrodesis. We treated the patients with a two step treatment plan. After radical debridement and sequestrectomy the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted in the tibia and in the calcaneus and the gap was temporary filled with gentamicin beads as the first step. In the second step we performed an autologous bone graft after a period of four weeks. The case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues. Mean age at the index procedure was 49.7 years (18-82), 104 patients were male (67.1%). Follow up examination after mean 4.5 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. 92.7% of the cases lead to a stable arthrodesis. In 5 patients the arthrodesis was found partly-stable. In six patients (4,5%) the infection was not controllable during the treatment process. These patients had to be treated with a below knee amputation. The mean AOFAS score at follow up was 63.7 (53-92). Overall there is a high degree of remaining disability. The complication rate and the reduced patient comfort reserve this method mainly for infection. Joint salvage is possible in the majority of cases with an earlier stage I and II infection.
Hu, Zhihuang; Liang, Wenhua; Yang, Yunpeng; Keefe, Dorothy; Ma, Yuxiang; Zhao, Yuanyuan; Xue, Cong; Huang, Yan; Zhao, Hongyun; Chen, Likun; Chan, Alexandre; Zhang, Li
2016-01-01
Chemotherapy-induced nausea and vomiting (CINV) is presented in over 30% of cancer patients receiving highly/moderately emetogenic chemotherapy (HEC/MEC). The currently recommended antiemetic therapy is merely based on the emetogenic level of chemotherapy, regardless of patient's individual risk factors. It is, therefore, critical to develop an approach for personalized management of CINV in the era of precision medicine.A number of variables were involved in the development of CINV. In the present study, we pooled the data from 2 multi-institutional investigations of CINV due to HEC/MEC treatment in Asian countries. Demographic and clinical variables of 881 patients were prospectively collected as defined previously, and 862 of them had full documentation of variables of interest. The data of 548 patients from Chinese institutions were used to identify variables associated with CINV using multivariate logistic regression model, and then construct a personalized prediction model of nomogram; while the remaining 314 patients out of China (Singapore, South Korea, and Taiwan) entered the external validation set. C-index was used to measure the discrimination ability of the model.The predictors in the final model included sex, age, alcohol consumption, history of vomiting pregnancy, history of motion sickness, body surface area, emetogenicity of chemotherapy, and antiemetic regimens. The C-index was 0.67 (95% CI, 0.62-0.72) for the training set and 0.65 (95% CI, 0.58-0.72) for the validation set. The C-index was higher than that of any single predictor, including the emetogenic level of chemotherapy according to current antiemetic guidelines. Calibration curves showed good agreement between prediction and actual occurrence of CINV.This easy-to-use prediction model was based on chemotherapeutic regimens as well as patient's individual risk factors. The prediction accuracy of CINV occurrence in this nomogram was well validated by an independent data set. It could facilitate the assessment of individual risk, and thus improve the personalized management of CINV.
Heated Surface Temperatures Measured by Infrared Detector in a Cascade Environment
NASA Technical Reports Server (NTRS)
Boyle, Robert J.
2002-01-01
Investigators have used infrared devices to accurately measure heated surface temperatures. Several of these applications have been for turbine heat transfer studies involving film cooling and surface roughness, typically, these measurements use an infrared camera positioned externally to the test section. In cascade studies, where several blades are used to ensure periodic flow, adjacent blades block the externally positioned camera's views of the test blade. To obtain a more complete mapping of the surface temperatures, researchers at the NASA Glenn Research Center fabricated a probe with an infrared detector to sense the blade temperatures. The probe size was kept small to minimize the flow disturbance. By traversing and rotating the probe, using the same approach as for total pressure surveys, one can find the blade surface temperatures. Probe mounted infrared detectors are appropriate for measuring surface temperatures where an externally positioned infrared camera is unable to completely view the test object. This probe consists of a 8-mm gallium arsenide (GaAs) lens mounted in front of a mercury-cadmium-zinc-tellurium (HgCdZnTe) detector. This type of photovoltaic detector was chosen because of its high sensitivity to temperature when the detector is uncooled. The particular application is for relatively low surface temperatures, typically ambient to 100 C. This requires a detector sensitive at long wavelengths. The detector is a commercial product enclosed in a 9-mm-diameter package. The GaAs lens material was chosen because of its glass-like hardness and its good long-wavelength transmission characteristics. When assembled, the 6.4-mm probe stem is held in the traversing actuator. Since the entire probe is above the measurement plane, the flow field disturbance in the measurement plane is minimized. This particular probe body is somewhat wider than necessary, because it was designed to have replaceable detectors and lenses. The signal for the detector is fed through the hollow probe body. The detector's signal goes to an externally mounted preamplifier. The detector assembly, along with a preamplifier, is calibrated as a function of the surface temperature for various detector temperatures. The output voltage is a function of both the detector and object temperatures.
Costa-Berenguer, Xavier; García-García, Marta; Sánchez-Torres, Alba; Sanz-Alonso, Mariano; Figueiredo, Rui; Valmaseda-Castellón, Eduard
2018-01-01
To assess the effect of implantoplasty on the fracture resistance, surface roughness, and macroscopic morphology of standard diameter (4.1 mm) external connection dental implants. An in vitro study was conducted in 20 screw-shaped titanium dental implants with an external connection. In 10 implants, the threads and surface were removed and polished with high-speed burs (implantoplasty), while the remaining 10 implants were used as controls. The final implant dimensions were recorded. The newly polished surface quality was assessed by scanning electron microscopy (SEM) and by 3D surface roughness analysis using a confocal laser microscope. Finally, all the implants were subjected to a mechanical pressure resistance test. A descriptive analysis of the data was made. Also, Student's t tests were employed to detect differences regarding the compression tests. Implantoplasty was carried out for a mean time of 10 min and 48 s (standard deviation (SD) of 1 min 22 s). Macroscopically, the resulting surface had a smooth appearance, although small titanium shavings and silicon debris were present. The final surface roughness (S a values 0.1 ± 0.02 μm) was significantly lower than that of the original (0.75 ± 0.08 μm S a ) (p = .005). There was minimal reduction in the implant's inner body diameter (0.19 ± 0.03 mm), and no statistically significant differences were found between the test and control implants regarding the maximum resistance force (896 vs 880 N, respectively). Implantoplasty, although technically demanding and time-consuming, does not seem to significantly alter fracture resistance of standard diameter external connection implants. A smooth surface with S a values below 0.1 μm can be obtained through the use of silicon polishers. A larger sample is required to confirm that implantoplasty does not significantly affect the maximum resistance force of standard diameter external connection implants. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The stability of freak waves with regard to external impact and perturbation of initial data
NASA Astrophysics Data System (ADS)
Smirnova, Anna; Shamin, Roman
2014-05-01
We investigate solutions of the equations, describing freak waves, in perspective of stability with regard to external impact and perturbation of initial data. The modeling of freak waves is based on numerical solution of equations describing a non-stationary potential flow of the ideal fluid with a free surface. We consider the two-dimensional infinitely deep flow. For waves modeling we use the equations in conformal variables. The variant of these equations is offered in [1]. Mathematical correctness of these equations was discussed in [2]. These works establish the uniqueness of solutions, offer the effective numerical solution calculation methods, prove the numerical convergence of these methods. The important aspect of numerical modeling of freak waves is the stability of solutions, describing these waves. In this work we study the questions of stability with regards to external impact and perturbation of initial data. We showed the stability of freak waves numerical model, corresponding to the external impact. We performed series of computational experiments with various freak wave initial data and random external impact. This impact means the power density on free surface. In each experiment examine two waves: the wave that was formed by external impact and without one. In all the experiments we see the stability of equation`s solutions. The random external impact practically does not change the time of freak wave formation and its form. Later our work progresses to the investigation of solution's stability under perturbations of initial data. We take the initial data that provide a freak wave and get the numerical solution. In common we take the numerical solution of equation with perturbation of initial data. The computing experiments showed that the freak waves equations solutions are stable under perturbations of initial data.So we can make a conclusion that freak waves are stable relatively external perturbation and perturbation of initial data both. 1. Zakharov V.E., Dyachenko A.I., Vasilyev O.A. New method for numerical simulation of a nonstationary potential flow of incompressible fluid with a free surface// Eur. J.~Mech. B Fluids. 2002. V. 21. P. 283-291. 2. R.V. Shamin. Dynamics of an Ideal Liquid with a Free Surface in Conformal Variables // Journal of Mathematical Sciences, Vol. 160, No. 5, 2009. P. 537-678. 3. R.V. Shamin, V.E. Zakharov, A.I. Dyachenko. How probability for freak wave formation can be found // THE EUROPEAN PHYSICAL JOURNAL - SPECIAL TOPICS Volume 185, Number 1, 113-124, DOI: 10.1140/epjst/e2010-01242-y
Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F
2015-03-31
This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P < 0.05); however, there were no significant differences in radial-ulnar deviation, wrist range of motion, or wrist function score between groups (P > 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.
Ortiz, Marcos G.
1992-01-01
A method for modeling a conducting material sample or structure (herein called a system) as at least two regions which comprise an electrical network of resistances, for measuring electric resistance between at least two selected pairs of external leads attached to the surface of the system, wherein at least one external lead is attached to the surface of each of the regions, and, using basic circuit theory, for translating measured resistances into temperatures or thermophysical properties in corresponding regions of the system.
Ortiz, M.G.
1992-11-24
Disclosed is a method for modeling a conducting material sample or structure (herein called a system) as at least two regions which comprise an electrical network of resistances, for measuring electric resistance between at least two selected pairs of external leads attached to the surface of the system, wherein at least one external lead is attached to the surface of each of the regions, and, using basic circuit theory, for translating measured resistances into temperatures or thermophysical properties in corresponding regions of the system. 16 figs.
Dual mode fuel injector with one piece needle valve member
Lawrence, Keith E.; Hinrichsen, Michael H.; Buckman, Colby
2005-01-18
A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively by inner and outer needle value members. The homogenous charged nozzle outlet set is defined by an outer needle value member that is moveably positioned in an injector body, which defines the conventional nozzle outlet set. The inner needle valve member is positioned in the outer needle valve member. The outer needle valve member is a piece component that includes at least one external guide surface, an external value surface and an internal valve seat.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steiner, Myles A.; Perl, E. E.; Geisz, J. F.
Here, we demonstrate that in solar cells with highly reflective back mirrors, the measured internal quantum efficiency exhibits a shift in bandgap relative to the measured external quantum efficiency. The shift arises from the fact that the measured reflectance at the front surface includes a superposition of waves reflecting from the front and back surfaces. We quantify the magnitude of the apparent shift and discuss the errors that can result in determination of quantities such as the photocurrent. Because of this apparent shift, it is important that the bandgap be determined from the external quantum efficiency.
Electronics box having internal circuit cards interconnected to external connectors sans motherboard
NASA Technical Reports Server (NTRS)
Hockett, John E. (Inventor)
2005-01-01
An electronics chassis box includes a pair of opposing sidewalls, a pair of opposing end walls, a bottom surface, a top cover, and ring connectors assemblies mounted in selective ones of the walls of the electronic box. Boss members extend from the bottom surface at different heights upon which circuit cards are mounted in spatial relationship to each other. A flex interconnect substantially reduces and generally eliminates the need of a motherboard by interconnecting the circuit cards to one another and to external connectors mounted within the ring connector assemblies.
Farr, Sebastian; Kranzl, Andreas; Hahne, Julia; Ganger, Rudolf
2017-08-01
Literature suggests that children and adolescents with idiopathic genua valga present with considerable gait deviations in frontal and transverse planes, including altered frontal knee moments, reduced external knee rotation, and increased external hip rotation. This study aimed to evaluate gait parameters in these patients after surgical correction using tension band plating (TBP). We prospectively evaluated 24 consecutive, skeletally immature patients, who received full-length standing radiographs and three-dimensional gait analysis before and after correction, and compared the results observed to a group of 11 typically developing peers. Prior to TBP the cohort showed significantly decreased (worse) internal frontal knee moments compared to the control group. After axis correction the mean and maximum knee moments changed significantly into normalized knee moments (p < 0.0001). In the transverse plane, only the foot progression angle (p = 0.020) changed significantly following intervention. Post-correction knee moments were similar to controls (p = 0.175), but the patient cohort exhibited a significantly decreased knee external rotation (p = 0.004) and increased external hip rotation (p < 0.001) during gait. In addition, the effect of transverse plane changes on knee moments in patients with restored, straight limb axis was calculated. Hence, patients with restored alignment but persistence of decreased external knee rotation demonstrated significantly greater knee moments than those without rotational abnormalities (p = 0.001). This study found that frontal knee moments during gait normalized in children with idiopathic genua valga after surgery. However, decreased external knee rotation and increased external hip rotation during gait persisted in the study cohort. Despite radiological correction, decreased external rotation during gait was associated with increases in medial knee loading. Surgical correction for children with genua valga but normal knee moments may be detrimental, due to redistribution of dynamic knee loading into the opposite joint compartment. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1617-1624, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Patients' health beliefs and coping prior to autologous peripheral stem cell transplantation.
Frick, E; Fegg, M J; Tyroller, M; Fischer, N; Bumeder, I
2007-03-01
The aim of this study was to determine the associations between health locus of control (LoC), causal attributions and coping in tumour patients prior to autologous peripheral blood stem cell transplantation. Patients completed the Questionnaire of Health Related Control Expectancies, the Questionnaire of Personal Illness Causes (QPIC), and the Freiburg Questionnaire of Coping with Illness. A total of 126 patients (45% women; 54% suffering from a multiple myeloma, 29% from non-Hodgkin lymphomas, and 17% from other malignancies) participated in the study. Cluster analysis yielded four LoC clusters: 'fatalistic external', 'powerful others', 'yeah-sayer' and 'double external'. Self-blaming QPIC items were positively correlated with depressive coping, and 'fate or destiny' attributions with religious coping (P<0.001). The highest scores were found for 'active coping' in the LoC clusters 'powerful others' and 'yeah-sayer'. External LoC and an active coping style prevail before undergoing autologous peripheral blood stem cell transplantation, whereas the depressive coping is less frequent, associated with self-blaming causal attributions. Health beliefs include causal and control attributions, which can improve or impair the patient's adjustment. A mixture between internal and external attributions seems to be most adaptive.
Couto, Blas; Adolfi, Federico; Sedeño, Lucas; Salles, Alejo; Canales-Johnson, Andrés; Alvarez-Abut, Pablo; Garcia-Cordero, Indira; Pietto, Marcos; Bekinschtein, Tristan; Sigman, Mariano; Manes, Facundo; Ibanez, Agustin
2015-01-01
Interoception is the moment-to-moment sensing of the physiological condition of the body. The multimodal sources of interoception can be classified into two different streams of afferents: an internal pathway of signals arising from core structures (i.e., heart, blood vessels, and bronchi) and an external pathway of body-mapped sensations (i.e., chemosensation and pain) arising from peripersonal space. This study examines differential processing along these streams within the insular cortex (IC) and their subcortical tracts connecting frontotemporal networks. Two rare patients presenting focal lesions of the IC (insular lesion, IL) or its subcortical tracts (subcortical lesion, SL) were tested. Internally generated interoceptive streams were assessed through a heartbeat detection (HBD) task, while those externally triggered were tapped via taste, smell, and pain recognition tasks. A differential pattern was observed. The IC patient showed impaired internal signal processing while the SL patient exhibited external perception deficits. Such selective deficits remained even when comparing each patient with a group of healthy controls and a group of brain-damaged patients. These outcomes suggest the existence of distinguishable interoceptive streams. Results are discussed in relation with neuroanatomical substrates, involving a fronto-insulo-temporal network for interoceptive and cognitive contextual integration. PMID:25983697
Misgav, Mudi; Kenet, Gili; Martinowitz, Uriel
2014-03-01
Bleeding episodes in patients with congenital or acquired bleeding disorders are usually managed with factor concentrates or blood products. However, external and accessible bleeds may effectively be managed with topical hemostasis. After the application of the Hemcon, a Food and Drug Administration-approved chitosan-based hemostatic dressing was used as the "last resort" to successfully control external bleeds in 2 patients with severe bleeding disorders. We describe a single-center experience with this dressing, including its use in pediatric patients as the first mode of therapy. A total of 5 patients (median age 2 y) with severe bleeding disorders were treated with topical chitosan-based dressing for a total of 6 bleeding episodes. The dressing was used either after the failure of extensive systemic therapy or as the first choice of treatment. In 4 of the 6 episodes, bleeding ceased immediately alleviating the need for systemic therapy. There was no rebleeding after the removal of the dressing and no adverse events or local skin reactions were recorded. Hemostatic dressings, such as the chitosan, should be encouraged for the treatment of external/accessible bleeds, especially among the pediatric patients with bleeding tendency.
Browning, G. G.; Henry, M. M.; Motson, R. W.
1988-01-01
The management of seven patients with multiple injuries to the anal sphincter musculature and its nerve supply, from major pelvic trauma, anal fistula surgery, or obstetric trauma, was reviewed. All were either incontinent of solid stools or had defunctioning colostomies. Anal manometry was abnormal in all patients. Concentric needle electromyography (EMG) showed anterior division of the external sphincter in all the patients; five also had posterior division of both the external sphincter and puborectalis. EMG abnormalities were found in the lateral quadrants of these muscles, particularly the external sphincter. Single fibre needle EMG showed evidence of reinnervation in the external sphincter in six patients, and in the puborectalis in two, indicating partial denervation of the muscles. Treatment was by anterior sphincter repair using an overlapping technique, combined with postanal repair; the repairs were protected by a defunctioning colostomy. When assessed 4-60 months (mean 17 months) after colostomy closure all seven patients were continent of solid and semi-formed stools, but had urgency of defaecation. None could control liquid stool or flatus. After complicated sphincter injuries planned surgical reconstruction, based on EMG assessment of the sphincter muscles, can restore acceptable continence. PMID:3190132
Is a Responsive Default Mode Network Required for Successful Working Memory Task Performance?
Čeko, Marta; Gracely, John L.; Fitzcharles, Mary-Ann; Seminowicz, David A.; Schweinhardt, Petra
2015-01-01
In studies of cognitive processing using tasks with externally directed attention, regions showing increased (external-task-positive) and decreased or “negative” [default-mode network (DMN)] fMRI responses during task performance are dynamically responsive to increasing task difficulty. Responsiveness (modulation of fMRI signal by increasing load) has been linked directly to successful cognitive task performance in external-task-positive regions but not in DMN regions. To investigate whether a responsive DMN is required for successful cognitive performance, we compared healthy human subjects (n = 23) with individuals shown to have decreased DMN engagement (chronic pain patients, n = 28). Subjects performed a multilevel working-memory task (N-back) during fMRI. If a responsive DMN is required for successful performance, patients having reduced DMN responsiveness should show worsened performance; if performance is not reduced, their brains should show compensatory activation in external-task-positive regions or elsewhere. All subjects showed decreased accuracy and increased reaction times with increasing task level, with no significant group differences on either measure at any level. Patients had significantly reduced negative fMRI response (deactivation) of DMN regions (posterior cingulate/precuneus, medial prefrontal cortex). Controls showed expected modulation of DMN deactivation with increasing task difficulty. Patients showed significantly reduced modulation of DMN deactivation by task difficulty, despite their successful task performance. We found no evidence of compensatory neural recruitment in external-task-positive regions or elsewhere. Individual responsiveness of the external-task-positive ventrolateral prefrontal cortex, but not of DMN regions, correlated with task accuracy. These findings suggest that a responsive DMN may not be required for successful cognitive performance; a responsive external-task-positive network may be sufficient. SIGNIFICANCE STATEMENT We studied the relationship between responsiveness of the brain to increasing task demand and successful cognitive performance, using chronic pain patients as a probe. fMRI working memory studies show that two main cognitive networks [“external-task positive” and “default-mode network” (DMN)] are responsive to increasing task difficulty. The responsiveness of both of these brain networks is suggested to be required for successful task performance. The responsiveness of external-task-positive regions has been linked directly to successful cognitive task performance, as we also show here. However, pain patients show decreased engagement and responsiveness of the DMN but can perform a working memory task as well as healthy subjects, without demonstrable compensatory neural recruitment. Therefore, a responsive DMN might not be needed for successful cognitive performance. PMID:26290236
Is a Responsive Default Mode Network Required for Successful Working Memory Task Performance?
Čeko, Marta; Gracely, John L; Fitzcharles, Mary-Ann; Seminowicz, David A; Schweinhardt, Petra; Bushnell, M Catherine
2015-08-19
In studies of cognitive processing using tasks with externally directed attention, regions showing increased (external-task-positive) and decreased or "negative" [default-mode network (DMN)] fMRI responses during task performance are dynamically responsive to increasing task difficulty. Responsiveness (modulation of fMRI signal by increasing load) has been linked directly to successful cognitive task performance in external-task-positive regions but not in DMN regions. To investigate whether a responsive DMN is required for successful cognitive performance, we compared healthy human subjects (n = 23) with individuals shown to have decreased DMN engagement (chronic pain patients, n = 28). Subjects performed a multilevel working-memory task (N-back) during fMRI. If a responsive DMN is required for successful performance, patients having reduced DMN responsiveness should show worsened performance; if performance is not reduced, their brains should show compensatory activation in external-task-positive regions or elsewhere. All subjects showed decreased accuracy and increased reaction times with increasing task level, with no significant group differences on either measure at any level. Patients had significantly reduced negative fMRI response (deactivation) of DMN regions (posterior cingulate/precuneus, medial prefrontal cortex). Controls showed expected modulation of DMN deactivation with increasing task difficulty. Patients showed significantly reduced modulation of DMN deactivation by task difficulty, despite their successful task performance. We found no evidence of compensatory neural recruitment in external-task-positive regions or elsewhere. Individual responsiveness of the external-task-positive ventrolateral prefrontal cortex, but not of DMN regions, correlated with task accuracy. These findings suggest that a responsive DMN may not be required for successful cognitive performance; a responsive external-task-positive network may be sufficient. We studied the relationship between responsiveness of the brain to increasing task demand and successful cognitive performance, using chronic pain patients as a probe. fMRI working memory studies show that two main cognitive networks ["external-task positive" and "default-mode network" (DMN)] are responsive to increasing task difficulty. The responsiveness of both of these brain networks is suggested to be required for successful task performance. The responsiveness of external-task-positive regions has been linked directly to successful cognitive task performance, as we also show here. However, pain patients show decreased engagement and responsiveness of the DMN but can perform a working memory task as well as healthy subjects, without demonstrable compensatory neural recruitment. Therefore, a responsive DMN might not be needed for successful cognitive performance. Copyright © 2015 the authors 0270-6474/15/3511596-11$15.00/0.
Caron, M; Kron, E; Saltrick, K R
1999-04-01
The technical aspects of fusion of the rheumatoid ankle do not deviate from those in the post-traumatic or osteoarthritic ankle. Screw fixation can usually be achieved, and rarely is fixation failure a problem in rheumatoid ankle arthrodesis. If fixation is difficult because of deformity or bone quality, external fixation or locking intramedullary nails should be used. The placement of cannulated screws and adequacy of screw fixation has not been a problem (Fig. 13). Screw fixation provides compression and prevents rotation. The surgeon, however, needs to be assured that no screws invade the subtalar joint and that all threads are beyond the arthrodesis site. A washer may be necessary for further stability if this screw is not inserted at too great an angle. The authors have found that troughing out of the cortical surface of the tibia with a power bur aids in screw insertion. Not only does the trough act as a countersink, but it also provides a path for screw insertion and prevents palpable screw irritation. Malalignment is unforgiving. The foot must be placed neutral to dorsiflexion and plantarflexion. Equinus positioning places added stress on the tibia and a back-knee gait occurs. Approximately 5 degrees of valgus is recommended, and varus positioning is unforgiving. Internal and external rotation is determined by the position of the contralateral extremity. Nonunion does not seem to be a problem with rigid internal fixation to any greater degree in patients with RA. Despite this, patients may continue to have pain despite solid fusion, which can be caused by incomplete correction of deformity, painful internal fixation, or adjacent joint pathology. Additionally, patients may experience supramalleolar pain above the fusion site consistent with tibial stress fracture, which is more common if the subtalar or midtarsal joint is rigid or if the patient is obese. A rocker sole shoe with impact-absorbing soles used after brief periods of guarded mobilization in a removable walking cast alleviates this stress on the tibia. Neurovascular insult can be avoided with careful dissection direct to bone, incisions placed in nerve-free zones, and avoidance of plunging deep posteriorly-medially and anteriorly when dissecting and resecting surfaces. Arthrodesis of the tibiotalar joint in the patient with RA should be performed to relieve severe pain caused by advanced arthrosis. Achieving a solid arthrodesis does not seem to be a problem and provides the patient with pain relief; however, marked improvement in patient function and level of activity remains limited by the nature of RA and adjacent joint involvement.
Rubber band as external assist device to provide simple grip for quadriplegic patients.
Pham, H N; Noble, C N; Hentz, V R
1988-08-01
The rubber band as an external assist device provides an effective grip for the hand of high spinal cord injury quadriplegic patients. This technique can also be useful for preoperative patients who are undergoing physical and occupational therapy or to assess patients' needs for surgery. The rubber band as an adaptive device is preferred because of its availability, low visibility, and ease of application. We attempt to provide a more standardized method of the rubber band technique and to popularize it.
McKenzie, Suzanne H; Harris, Mark F
2013-11-01
The process of initiating and maintaining healthy lifestyle behaviours is complex, includes a number of distinct phases and is not static. Theoretical models of behaviour change consider psychological constructs such as intention and self efficacy but do not clearly consider the role of stress or psychological distress. General practice based interventions addressing lifestyle behaviours have been demonstrated to be feasible and effective however it is not clear whether general practitioners (GPs) take psychological health into consideration when discussing lifestyle behaviours. This qualitative study explores GPs' and patients' perspectives about the relationship between external stressors, psychological distress and maintaining healthy lifestyle behaviours. Semi-structured telephone interviews were conducted with 16 patients and 5 GPs. Transcripts from the interviews were thematically analysed and a conceptual model developed to explain the relationship between external stressors, psychological distress and healthly lifestyle behaviours. Participants were motivated to maintain a healthy lifestyle however they described a range of external factors that impacted on behaviour in both positive and negative ways, either directly or via their impact on psychological distress. The impact of external factors was moderated by coping strategies, beliefs, habits and social support. In some cases the process of changing or maintaining healthy behaviour also caused distress. The concept of a threshold level of distress was evident in the data with patients and GPs describing a certain level of distress required before it negatively influenced behaviour. Maintaining healthy lifestyle behaviours is complex and constantly under challenge from external stressors. Practitioners can assist patients with maintaining healthy behaviour by providing targeted support to moderate the impact of external stressors.
Liu, Shou-Xin; Chen, Xi; Zhang, Xian-Quan
2008-05-01
Commercial activated carbon was treated by HNO3 oxidation and then subsequently heat treated under N2 atmosphere. Effect of surface chemical properties and pore structure on the adsorption performance of nitrobenzene was investigated. N2/77K adsorption isotherm and scanning electron microscopy (SEM) were used to characterize the pore structure and surface morphology of carbon. Boehm titration, Fourier transform infrared spectroscopy (FTIR), the point of zero charge (pH(PZC)) measurement and elemental analysis were used to characterize the surface properties. The results reveal that HNO3 oxidation can modify the surface chemical properties, increase the number of acidic surface oxygen-containing groups and has trivial effect on the pore structure of carbon. Further heat treatment can cause the decomposition of surface oxygen-containing groups, and increase the external surface area and the number of mesopores. Adsorption capacity of nitrobenzene on AC(NO-T), AC(raw) and AC(NO) was 1011.31, 483.09 and 321.54 mg x g(-1), respectively. Larger external surface area and the number of meso-pores, together with the less acid surface oxygen-containing groups were the main reason for the larger adsorption capacity AC(NO-T).
He, Jiang-Hong; Yang, Yi; Zhang, Yi; Qiu, Si-You; Zhou, Zhen-Yu; Dang, Yuan-Yuan; Dai, Yi-Wu; Liu, Yi-Jun; Xu, Ru-Xiang
2014-08-01
Resting-state functional MRI (fMRI) has emerged as a valuable tool to characterize the complex states encompassing disorders of consciousness (DOC). Awareness appears to comprise two coexistent, anticorrelated components named the external and internal awareness networks. The present study hypothesizes that DOC interrupts the balance between the internal and external awareness networks. To gain more understanding of this phenomenon, the present study analyzed resting-state fMRI data from 12 patients with DOC versus 12 healthy age-matched controls. The data were explored using independent component analysis and amplitude of low-frequency fluctuation (ALFF) analysis. The results indicated that DOC deactivated midline areas associated with internal awareness. In addition, external awareness was strengthened in DOC because of increased activation in the insula, lingual gyrus, paracentral and supplementary motor area. The activity patterns suggested strengthened external awareness against weakened internal awareness in DOC. In particular, increased activity found in the insula, lingual gyrus, paracentral and supplementary motor area of patients with DOC implied possible involvement of augmented visuo-motor modulation in these patients. DOC is probably related to hyperactive external awareness opposing hypoactive internal awareness. This unique pattern of brain activity may potentially be a prognostic marker for DOC. Copyright © 2014 John Wiley & Sons, Ltd.
Favre, Philippe; Loeb, Michael D; Helmy, Naeder; Gerber, Christian
2008-01-01
In patients with pseudoparesis of the shoulder resulting from irreparable rotator cuff tears, reverse shoulder arthroplasty (RSA) can restore active elevation, but external rotation remains less predictable. Latissimus dorsi transfer (LDT) has been shown to be effective in restoring external rotation in patients with posterosuperior tears of the rotator cuff. The aim of this study is to determine the capacity of the LDT to restore external rotation in combination with RSA and to investigate the mechanical advantage produced by 3 different insertion sites. A biomechanical model was created using a reverse total shoulder prosthesis with 3 different transfer insertions. Moment arms were measured for 2 static positions and 1 motion of the humerus. The moment arm analysis showed that LDT can improve active external rotation in the setting of a reverse prosthesis. An insertion site on the posterior side of the greater tuberosity (adjacent to the teres minor insertion) produced a greater external rotation moment arm.
External ear anomalies and hearing impairment in Noonan Syndrome.
van Trier, Dorothée C; van Nierop, Josephine; Draaisma, Jos M Th; van der Burgt, Ineke; Kunst, Henricus; Croonen, Ellen A; Admiraal, Ronald J C
2015-06-01
This is the first cohort in which hearing impairment and external ear anomalies in Noonan Syndrome are described extensively. Retrospective analysis of the otorhinolaryngological and clinical genetic data from 97 Noonan Syndrome (NS) patients. Forty-four NS patients were seen by an otorhinolaryngologist for the analysis of hearing impairment. In our cohort 80 of the 97 patients were genetically tested. In 71 of these mutations were found: in 48 patients a mutation in PTPN11, in 10 patients in SOS1, in 5 patients in SHOC2, in 5 patients in RAF1, in 1 patient in MAP2K2, in 1 patient in KRAS and in 1 patient in A2ML1. External ear anomalies were reported in 75 NS patients (77%). In 69 patients the ears were low-set, 28 patients had posteriorly rotated ears, 14 patients showed protruding ears and 18 had thickened helices. Hearing impairment was detected in 34 NS patients. Nine patients had sensorineural hearing impairment, two a permanent conductive hearing impairment, two other patients had mixed hearing impairment and 20 patients had conductive hearing impairment in the past, caused by otitis media with effusion. Their temporary conductive hearing impairment resolved between the ages of 2 and 18 years. Sensorineural hearing impairment varied between mild high-frequency hearing impairment and profound (uni- and bilateral) hearing impairment and was progressive in three patients. Four NS patients received cochlear implants for their severe sensorineural hearing impairment. The cohort is small for genotype-phenotype correlations, but sensorineural hearing impairment, especially the bilateral severe hearing impairment, was only seen in patients with a PTPN11 mutation. NS is characterized by dysmorphic external ear anomalies and both sensorineural and conductive hearing impairment. Audiological examinations are recommended in all patients with Noonan Syndrome. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Kopylov, Philippe; Geijer, Mats; Tägil, Magnus
2009-01-01
Background and purpose In unstable distal radial fractures that are impossible to reduce or to maintain in reduced position, the treatment of choice is operation. The type of operation and the choice of implant, however, is a matter of discussion. Our aim was to investigate whether open reduction and internal fixation would produce a better result than traditional external fixation. Methods 50 patients with an unstable or comminute distal radius fracture were randomized to either closed reduction and bridging external fixation, or open reduction and internal fixation using the TriMed system. The primary outcome parameter was grip strength, but the patients were followed for 1 year with objective clinical assessment, subjective outcome using DASH, and radiographic examination. Results At 1 year postoperatively, grip strength was 90% (SD 16) of the uninjured side in the internal fixation group and 78% (17) in the external fixation group. Pronation/supination was 150° (15) in the internal fixation group and 136° (20) in the external fixation group at 1 year. There were no differences in DASH scores or in radiographic parameters. 5 patients in the external fixation group were reoperated due to malunion, as compared to 1 in the internal fixation group. 7 other cases were classified as radiographic malunion: 5 in the external fixation group and 2 in the internal fixation group. Interpretation Internal fixation gave better grip strength and a better range of motion at 1 year, and tended to have less malunions than external fixation. No difference could be found regarding subjective outcome. PMID:19857180
The sandwich technique for repair of pectus carinatum and excavatum/carinatum complex.
Park, Hyung Joo; Kim, Kyung Soo
2016-09-01
Simple external compression of pectus carinatum seems to have its limitations, particularly the repair of asymmetric pectus carinatum or excavatum/carinatum complex. We devised the sandwich technique (press-molding) to remodel the entire chest wall. The purpose of this study is to introduce the sandwich technique and appraise the early results. Between January 2007 and January 2016, 523 consecutive patients with pectus carinatum and its variants were analyzed retrospectively. No patients were excluded during the study period. The sandwich 1 and 2 techniques using the internal and external pectus bars were for pectus carinatum repair. Modified techniques using the external string and the internal bar were to treat the lower costal flare (the flare-buster) and focal protuberances (the magic string) in pectus excavatum repair. Statistical analyses were carried out using paired and unpaired t -test or Wilcoxon signed rank tests. The sandwich repair with the external and internal bars was applied to 58 pectus carinatum patients: seven symmetric (12.1%), 14 asymmetric (24.1%), and 37 carinatum-excavatum complex (63.8%). After pectus excavatum repair, 426 patients had the flare-buster and 39 patients received the magic string. The sandwich 1 technique achieved near-complete resolution of carinatum in 52 patients (86.2%). The sandwich 2 technique accomplished almost symmetric configuration with no residual carinatum in all six cases. The sandwich technique using the external and internal bars seems to be effective in treating asymmetric pectus carinatum and complex excavatum/carinatum deformities. The flare-buster and the magic string effectively relieve the costal flare and focal protuberances in pectus excavatum repair.
van Dyk, Sylvia; Kondalsamy-Chennakesavan, Srinivas; Schneider, Michal; Bernshaw, David; Narayan, Kailash
2014-03-15
To compare measurements of the uterus and cervix obtained with magnetic resonance imaging (MRI) and transabdominal ultrasound to determine whether ultrasound can identify the brachytherapy target and be used to guide conformal brachytherapy planning and treatment for cervix cancer. Consecutive patients undergoing curative treatment with radiation therapy between January 2007 and March 2012 were included in the study. Intrauterine applicators were inserted into the uterine canal while patients were anesthetized. Images were obtained by MRI and transabdominal ultrasound in the longitudinal axis of the uterus with the applicator in treatment position. Measurements were taken at the anterior and posterior surface of the uterus at 2.0-cm intervals along the applicator, from the external os to the tip of the applicator. Data were analyzed using Bland Altman plots examining bias and 95% limits of agreement. A total of 192 patients contributed 1668 measurements of the cervix and uterus. Mean (± SD) differences of measurements between imaging modalities at the anterior and posterior uterine surface ranged from 1.5 (± 3.353) mm to 3.7 (± 3.856) mm, and -1.46 (± 3.308) mm to 0.47 (± 3.502) mm, respectively. The mean differences were less than 3 mm in the cervix. The mean differences were less than 1.5 mm at all measurement points on the posterior surface. Differences in the measurements of the cervix and uterus obtained by MRI and ultrasound were within clinically acceptable limits. Transabdominal ultrasound can be substituted for MRI in defining the target volume for conformal brachytherapy treatment of cervix cancer. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Narayana, V; McLaughlin, P; University of Michigan, Ann Arbor, MI
2015-06-15
Purpose: In this study, the adequacy of target expansions on the combined external beam and implant dose was examined based on the measured daily motion of the prostate. Methods: Thirty patients received an I–125 prostate implant prescribed to dose of 90Gy. This was followed by external beam to deliver a dose of 90Gyeq (external beam equivalent) to the prostate over 25 to 30 fractions. An ideal IMRT plan was developed by optimizing the external beam dose based on the delivered implant dose. The implant dose was converted to an equivalent external beam dose using the linear quadratic model. Patients weremore » set up on the treatment table by daily orthogonal imaging and aligning the marker seeds in the prostate. Orthogonal images were obtained at the end of treatment to assess prostate intrafraction motion. Based on the observed motion of the markers between the initial and final images, 5 individual plans showing the actual dose delivered to the patient were calculated. A final true dose distribution was established based on summing the implant dose and the 5 external beam plans. Dose to the prostate, seminal vesicles, lymphnodes and normal tissues, rectal wall, urethra and lower sphincter were calculated and compared to ideal. On 18 patients who were sexually active, dose to the corpus cavernosum and internal pudendal artery was also calculated. Results: The average prostate motion in 3 orthogonal directions was less than 1 mm with a standard deviation of less than +2 mm. Dose and volume parameters showed that there was no decrease in dose to the targets and a marginal decrease in dose to in normal tissues. Conclusion: Dose delivered by seed implant moves with the prostate, decreasing the impact of intrafractions dose movement on actual dose delivered. Combined brachytherapy and external beam dose delivered to the prostate was not sensitive to prostate motion.« less
Nankali, Saber; Torshabi, Ahmad Esmaili; Miandoab, Payam Samadi; Baghizadeh, Amin
2016-01-08
In external-beam radiotherapy, using external markers is one of the most reliable tools to predict tumor position, in clinical applications. The main challenge in this approach is tumor motion tracking with highest accuracy that depends heavily on external markers location, and this issue is the objective of this study. Four commercially available feature selection algorithms entitled 1) Correlation-based Feature Selection, 2) Classifier, 3) Principal Components, and 4) Relief were proposed to find optimum location of external markers in combination with two "Genetic" and "Ranker" searching procedures. The performance of these algorithms has been evaluated using four-dimensional extended cardiac-torso anthropomorphic phantom. Six tumors in lung, three tumors in liver, and 49 points on the thorax surface were taken into account to simulate internal and external motions, respectively. The root mean square error of an adaptive neuro-fuzzy inference system (ANFIS) as prediction model was considered as metric for quantitatively evaluating the performance of proposed feature selection algorithms. To do this, the thorax surface region was divided into nine smaller segments and predefined tumors motion was predicted by ANFIS using external motion data of given markers at each small segment, separately. Our comparative results showed that all feature selection algorithms can reasonably select specific external markers from those segments where the root mean square error of the ANFIS model is minimum. Moreover, the performance accuracy of proposed feature selection algorithms was compared, separately. For this, each tumor motion was predicted using motion data of those external markers selected by each feature selection algorithm. Duncan statistical test, followed by F-test, on final results reflected that all proposed feature selection algorithms have the same performance accuracy for lung tumors. But for liver tumors, a correlation-based feature selection algorithm, in combination with a genetic search algorithm, proved to yield best performance accuracy for selecting optimum markers.
Drysdale, Cheri L.; Earl, Jennifer E.
2004-01-01
Objective: To investigate surface electromyographic (EMG) activity of the rectus abdominus and external oblique abdominus muscles during pelvic-tilt and abdominal-hollowing exercises performed in different positions. Design and Setting: 2 × 3 (exercise by position) within-subjects design with repeated measures on both factors. All testing was performed in a university laboratory. Subjects: Twenty-six healthy, active young adult females. Measurements: Surface EMG activity was recorded from the left and right rectus abdominus and external oblique muscles while the 2 exercises (pelvic tilt and abdominal hollowing) were performed in different positions (standard, legs supported, and legs unsupported). The standard position was supine in the crook-lying position, the supported position was with hips and knees flexed to 90° and legs supported on a platform, and the unsupported position was with hips and knees flexed to 90° without external support. Peak EMG activity was normalized to a maximum voluntary isometric contraction for each muscle. Results: For the rectus abdominus, there was an interaction between position and activity. Abdominal hollowing produced significantly less activity than the pelvic tilt in all positions. The difference between the 2 exercises with the legs unsupported was of a greater magnitude than the other 2 positions. For the external obliques, there was significantly lower activity during the abdominal hollowing compared with the pelvic tilting. The greatest muscle activity occurred with the legs-unsupported position during both exercises. Conclusions: Abdominal-hollowing exercises produced less rectus abdominus and external oblique activity than pelvic-tilting exercises. Abdominal hollowing may be performed with minimal activation of the large global abdominal muscles. PMID:15085209
Drysdale, Cheri L.; Earl, Jennifer E.; Hertel, Jay
2004-03-01
OBJECTIVE: To investigate surface electromyographic (EMG) activity of the rectus abdominus and external oblique abdominus muscles during pelvic-tilt and abdominal-hollowing exercises performed in different positions. DESIGN AND SETTING: 2 x 3 (exercise by position) within-subjects design with repeated measures on both factors. All testing was performed in a university laboratory. SUBJECTS: Twenty-six healthy, active young adult females. MEASUREMENTS: Surface EMG activity was recorded from the left and right rectus abdominus and external oblique muscles while the 2 exercises (pelvic tilt and abdominal hollowing) were performed in different positions (standard, legs supported, and legs unsupported). The standard position was supine in the crook-lying position, the supported position was with hips and knees flexed to 90 degrees and legs supported on a platform, and the unsupported position was with hips and knees flexed to 90 degrees without external support. Peak EMG activity was normalized to a maximum voluntary isometric contraction for each muscle. RESULTS: For the rectus abdominus, there was an interaction between position and activity. Abdominal hollowing produced significantly less activity than the pelvic tilt in all positions. The difference between the 2 exercises with the legs unsupported was of a greater magnitude than the other 2 positions. For the external obliques, there was significantly lower activity during the abdominal hollowing compared with the pelvic tilting. The greatest muscle activity occurred with the legs-unsupported position during both exercises. CONCLUSIONS: Abdominal-hollowing exercises produced less rectus abdominus and external oblique activity than pelvic-tilting exercises. Abdominal hollowing may be performed with minimal activation of the large global abdominal muscles.
Load-dependent assembly of the bacterial flagellar motor.
Tipping, Murray J; Delalez, Nicolas J; Lim, Ren; Berry, Richard M; Armitage, Judith P
2013-08-20
It is becoming clear that the bacterial flagellar motor output is important not only for bacterial locomotion but also for mediating the transition from liquid to surface living. The output of the flagellar motor changes with the mechanical load placed on it by the external environment: at a higher load, the motor runs more slowly and produces higher torque. Here we show that the number of torque-generating units bound to the flagellar motor also depends on the external mechanical load, with fewer stators at lower loads. Stalled motors contained at least as many stators as rotating motors at high load, indicating that rotation is unnecessary for stator binding. Mutant stators incapable of generating torque could not be detected around the motor. We speculate that a component of the bacterial flagellar motor senses external load and mediates the strength of stator binding to the rest of the motor. The transition between liquid living and surface living is important in the life cycles of many bacteria. In this paper, we describe how the flagellar motor, used by bacteria for locomotion through liquid media and across solid surfaces, is capable of adjusting the number of bound stator units to better suit the external load conditions. By stalling motors using external magnetic fields, we also show that rotation is not required for maintenance of stators around the motor; instead, torque production is the essential factor for motor stability. These new results, in addition to previous data, lead us to hypothesize that the motor stators function as mechanosensors as well as functioning as torque-generating units.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsao, May N.; Mehta, Minesh P.; Whelan, Timothy J.
2005-09-01
Purpose: To systematically review the evidence for the use of stereotactic radiosurgery or stereotactic fractionated radiation therapy in adult patients with malignant glioma. Methods: Key clinical questions to be addressed in this evidence-based review were identified. Outcomes considered were overall survival, quality of life or symptom control, brain tumor control or response and toxicity. MEDLINE (1990-2004 June Week 2), CANCERLIT (1990-2003), CINAHL (1990-2004 June Week 2), EMBASE (1990-2004 Week 25), and the Cochrane library (2004 issue 2) databases were searched using OVID. In addition, the Physician Data Query clinical trials database, the proceedings of the American Society of Clinical Oncologymore » (1997-2004), ASTRO (1997-2004), and the European Society of Therapeutic Radiology and Oncology (ESTRO) (1997-2003) were searched. Data from the literature search were reviewed and tabulated. This process included an assessment of the level of evidence. Results: For patients with newly diagnosed malignant glioma, radiosurgery as boost therapy with conventional external beam radiation was examined in one randomized trial, five prospective cohort studies, and seven retrospective series. There is Level I evidence that the use of radiosurgery boost followed by external beam radiotherapy and carmustine (BCNU) does not confer benefit with respect to overall survival, quality of life, or patterns of failure as compared with external beam radiotherapy and BCNU. There is Level I-III evidence of toxicity associated with radiosurgery boost as compared with external beam radiotherapy alone. The results of the prospective and retrospective studies may be influenced by selection bias. Radiosurgery used as salvage for recurrent or progressive malignant glioma after conventional external beam radiotherapy failure was reported in zero randomized trials, three prospective cohort studies, and five retrospective series. The available data are sparse and insufficient to make absolute recommendations. Stereotactic fractionated radiation therapy has been reported as boost therapy with external beam radiotherapy for patients with newly diagnosed malignant glioma in only three prospective studies. As primary therapy alone without conventional external beam radiotherapy for newly diagnosed malignant glioma patients, stereotactic fractionated radiation therapy has been reported in only one prospective study. There were only three prospective series and two retrospective studies reported for patients with recurrent or progressive malignant glioma. Conclusions: For patients with malignant glioma, there is Level I-III evidence that the use of radiosurgery boost followed by external beam radiotherapy and BCNU does not confer benefit in terms of overall survival, local brain control, or quality of life as compared with external beam radiotherapy and BCNU. The use of radiosurgery boost is associated with increased toxicity. For patients with malignant glioma, there is insufficient evidence regarding the benefits/harms of using radiosurgery at the time progression or recurrence. There is also insufficient evidence regarding the benefits/harms in the use of stereotactic fractionated radiation therapy for patients with newly diagnosed or progressive/recurrent malignant glioma.« less
2017-01-01
Metal–organic frameworks (MOFs) are a class of modular, crystalline, and porous materials that hold promise for storage and transport of chemical cargoes. Though MOFs have been studied in bulk forms, ways of deliberately manipulating the external surface functionality of MOF nanoparticles are less developed. A generalizable approach to modify their surfaces would allow one to impart chemical functionality onto the particle surface that is independent of the bulk MOF structure. Moreover, the use of a chemically programmable ligand, such as DNA, would allow for the manipulation of interparticle interactions. Herein, we report a coordination chemistry-based strategy for the surface functionalization of the external metal nodes of MOF nanoparticles with terminal phosphate-modified oligonucleotides. The external surfaces of nine distinct archetypical MOF particles containing four different metal species (Zr, Cr, Fe, and Al) were successfully functionalized with oligonucleotides, illustrating the generality of this strategy. By taking advantage of the programmable and specific interactions of DNA, 11 distinct MOF particle–inorganic particle core–satellite clusters were synthesized. In these hybrid nanoclusters, the relative stoichiometry, size, shape, and composition of the building blocks can all be independently controlled. This work provides access to a new set of nucleic acid–nanoparticle conjugates, which may be useful as programmable material building blocks and as probes for measuring and manipulating intracellular processes. PMID:28718644
Shingles, A; McKenzie, D J; Claireaux, G; Domenici, P
2005-01-01
In hypoxia, gray mullet surface to ventilate well-oxygenated water in contact with air, an adaptive response known as aquatic surface respiration (ASR). Reflex control of ASR and its behavioral modulation by perceived threat of aerial predation and turbid water were studied on mullet in a partly sheltered aquarium with free surface access. Injections of sodium cyanide (NaCN) into either the bloodstream (internal) or ventilatory water stream (external) revealed that ASR, hypoxic bradycardia, and branchial hyperventilation were stimulated by chemoreceptors sensitive to both systemic and water O2 levels. Sight of a model avian predator elicited bradycardia and hypoventilation, a fear response that inhibited reflex hyperventilation following external NaCN. The time lag to initiation of ASR following NaCN increased, but response intensity (number of events, time at the surface) was unchanged. Mullet, however, modified their behavior to surface under shelter or near the aquarium edges. Turbid water abolished the fear response and effects of the predator on gill ventilation and timing of ASR following external NaCN, presumably because of reduced visibility. However, in turbidity, mullet consistently performed ASR under shelter or near the aquarium edges. These adaptive modulations of ASR behavior would allow mullet to retain advantages of the chemoreflex when threatened by avian predators or when unable to perceive potential threats in turbidity.
Local versus general anesthesia for external dacryocystorhinostomy in young patients.
Ciftci, Ferda; Pocan, Sibel; Karadayi, Koray; Gulecek, Oguz
2005-05-01
To compare the effectiveness, complications, and patient acceptance of local anesthesia with general anesthesia in young patients for external dacryocystorhinostomy (DCR). Data were prospectively collected over an 8-year period (1996-2004) on young patients (mean age: 22.64+/-1.71) undergoing external DCR in Gulhane Military Medical Academy. Patients were randomly allocated in two groups: general anesthesia (GA) and local anesthesia (LA). Of the 480 DCR procedures, 182 were performed with general anesthesia (44 bilateral), 298 were performed with local anesthesia (32 bilateral). Visual analogue scales were recorded in the postoperative 2-hour period. Postoperative nausea and vomiting (PONV), epistaxis, length of hospital stay, and intraoperative bleeding were noted. Patients in both groups reported being comfortable during and immediately after surgery. Only 2 patients in the LA group required additional local anesthetic because of pain. Intraoperative bleeding was lower in the LA group. Analgesic requirement and signs of nausea and vomiting in the GA group were higher in the early postoperative period (p<0.05). The incidence of PONV was higher (p<0.05) in the GA group. Postoperative epistaxis was observed in 12 patients in the GA group and just 2 patients in the LA group. Length of hospital stay was 2.29+/-0.46 days in the GA group, and 1.23+/-0.42 days in the LA group (p<0.01). Local anesthesia in DCR is safe and comfortable when proper anatomical approach to nerve blocks is performed correctly. Local anesthesia in young patients undergoing external DCR is a good alternative because it is cost-effective and it eliminates the complications of general anesthesia.
Fan, Wei-Li; Sun, Hong-Zhen; Wu, Si-Yu; Wang, Ai-Min
2013-03-01
The most common treatment for old calcaneal fractures accompanied by subtalar joint injury is the use of subtalar in situ arthrodesis and subtalar distraction bone-block arthrodesis or osteotomy. This article describes the introduction of a novel surgical treatment, gradual subtalar distraction with external fixation and restoration of the calcaneal height, and presents an assessment of its efficacy. The protruding lateral calcaneus and the articular surfaces and subchondral bone of the posterior facet of the subtalar joint were surgically removed. An external fixator, attached with 2 pins in the subcutaneous tibia and 2 pins in the posterolateral calcaneus, was used to fix the subtalar joint for 7 to 10 days followed by gradual subtalar distraction at 1 mm/d. The lengthening procedure was stopped when the calcaneal height was restored according to radiography. The external fixator was removed after bone fusion. Seven cases of old calcaneal fractures accompanied by severe subtalar joint injury (8 feet) were treated using this method. Average follow-up was 14.3 months (range, 7-36 months). In all 7 cases (1 case of both feet), the postoperative wound healed primarily. The calcaneal heights of all 8 feet were partially restored. Subtalar joint bone fusion was completed within 4 to 6 months after the operation. The average preoperative American Orthopedic Foot & Ankle Society (AOFAS) hindfoot score was 25.3, and the average postoperative AOFAS score was 76.3. Subtalar distraction osteogenesis with external fixation was a novel and effective method for the treatment of old calcaneal fractures accompanied by severe subtalar joint injury in this small group of patients. Level IV, retrospective case series.
Critical analysis of the condensation of water vapor at external surface of the duct
NASA Astrophysics Data System (ADS)
Kumar, Dileep; Memon, Rizwan Ahmed; Memon, Abdul Ghafoor; Ali, Intizar; Junejo, Awais
2018-01-01
In this paper, the effects of contraction of the insulation of the air duct of heating, ventilation, and air conditioning (HVAC) system is investigated. The compression of the insulation contracts it at joint, turn and other points of the duct. The energy loss and the condensation resulted from this contraction are also estimated. A mathematical model is developed to simulate the effects of this contraction on the heat gain, supply air temperature and external surface temperature of the duct. The simulation uses preliminary data obtained from an HVAC system installed in a pharmaceutical company while varying the operating conditions. The results reveal that insulation thickness should be kept greater than 30 mm and the volume flow rate of the selected air distribution system should be lower than 1.4m3/s to subside condensation on the external surface of the duct. Additionally, the optimum insulation thickness was determined by considering natural gas as an energy source and fiberglass as an insulation material. The optimum insulation thickness determined for different duct sizes varies from 28 to 45 mm, which is greater than the critical insulation thickness. Therefore, the chances of condensation on the external surface of the duct could be avoided at an optimum insulation thickness. Moreover, the effect of pressure loss coefficient of the duct fitting of air distribution system is estimated. The electricity consumption in air handling unit (AHU) decreases from 2.1 to 1.5 kW by decreasing the pressure loss coefficient from 1.5 to 0.5.
Critical analysis of the condensation of water vapor at external surface of the duct
NASA Astrophysics Data System (ADS)
Kumar, Dileep; Memon, Rizwan Ahmed; Memon, Abdul Ghafoor; Ali, Intizar; Junejo, Awais
2018-07-01
In this paper, the effects of contraction of the insulation of the air duct of heating, ventilation, and air conditioning (HVAC) system is investigated. The compression of the insulation contracts it at joint, turn and other points of the duct. The energy loss and the condensation resulted from this contraction are also estimated. A mathematical model is developed to simulate the effects of this contraction on the heat gain, supply air temperature and external surface temperature of the duct. The simulation uses preliminary data obtained from an HVAC system installed in a pharmaceutical company while varying the operating conditions. The results reveal that insulation thickness should be kept greater than 30 mm and the volume flow rate of the selected air distribution system should be lower than 1.4m3/s to subside condensation on the external surface of the duct. Additionally, the optimum insulation thickness was determined by considering natural gas as an energy source and fiberglass as an insulation material. The optimum insulation thickness determined for different duct sizes varies from 28 to 45 mm, which is greater than the critical insulation thickness. Therefore, the chances of condensation on the external surface of the duct could be avoided at an optimum insulation thickness. Moreover, the effect of pressure loss coefficient of the duct fitting of air distribution system is estimated. The electricity consumption in air handling unit (AHU) decreases from 2.1 to 1.5 kW by decreasing the pressure loss coefficient from 1.5 to 0.5.
Wilk, Amber R; Edwards, Leah B; Edwards, Erick B
2017-04-01
Although the Organ Procurement and Transplantation Network (OPTN) database contains a rich set of data on United States transplant recipients, follow-up data may be incomplete. It was of interest to determine if augmenting OPTN data with external death data altered patient survival estimates. Solitary kidney, liver, heart, and lung transplants performed between January 1, 2011, and January 31, 2013, were queried from the OPTN database. Unadjusted Kaplan-Meier 3-year patient survival rates were computed using 4 nonmutually exclusive augmented datasets: OPTN only, OPTN + verified external deaths, OPTN + verified + unverified external deaths (OPTN + all), and an additional source extending recipient survival time if no death was found in OPTN + all (OPTN + all [Assumed Alive]). Pairwise comparisons were made using unadjusted Cox Proportional Hazards analyses applying Bonferroni adjustments. Although differences in patient survival rates across data sources were small (≤1 percentage point), OPTN only data often yielded slightly higher patient survival rates than sources including external death data. No significant differences were found, including comparing OPTN + verified (hazard ratio [HR], 1.05; 95% confidence interval [95% CI], 1.00-1.10); P = 0.0356), OPTN + all (HR, 1.06; 95% CI, 1.01-1.11; P = 0.0243), and OPTN + all (Assumed Alive) (HR, 1.00; 95% CI, 0.96-1.05; P = 0.8587) versus OPTN only, or OPTN + verified (HR, 1.05; 95% CI, 1.00-1.10; P = 0.0511), and OPTN + all (HR, 1.05; 95% CI, 1.00-1.10; P = 0.0353) versus OPTN + all (Assumed Alive). Patient survival rates varied minimally with augmented data sources, although using external death data without extending the survival time of recipients not identified in these sources results in a biased estimate. It remains important for transplant centers to maintain contact with transplant recipients and obtain necessary follow-up information, because this information can improve the transplantation process for future recipients.
Badakh, Dinesh K; Grover, Amit H
2014-01-01
The purpose of this study was to analyze the impact of intra-cavitary brachytherapy (ICBT) as boost radiation after external beam radiotherapy (EBRT) in carcinoma of the external auditory canal and middle ear (EACMA): A retrospective analysis. A retrospective study of 18 patients with carcinoma of the EACMA who were treated with a curative intent from the year 1998 to 2010 was carried out. The age of the patients ranged from 25 years to 67 years. There were 11 male patients (61.1%) and 7 female patients (38.9%). A total of 15 (88.2%) patients were treated with curative radiation alone after a biopsy and two patients received post-operative radiation therapy. The patients were initially treated with EBRT with cobalt 60 machine up to 60-64 Gy. In our department, all the patients who were technically suitable for ICBT received an ICBT boost. The overall survival (OS) in these patients ranged from 7 months to 151 months (9 out of 17 patients, no evidence of disease 53%). The OS in patients treated with a combination of EBRT with ICBT was (8 out of 11) 72.7%, P value statistically significant (P value: 0.0024). The multivariate analysis shows statistically significant difference only for patients who got an ICBT boost (P Value: 0.020). ICBT as a boost after EBRT has got a positive impact on the OS. In conclusion, our results demonstrate that radical radiation therapy (EBRT and ICBT) is the treatment of choice for stage T2, carcinoma of EACMA.
The influence of bone density on the radiotherapy of cervix cancer
NASA Astrophysics Data System (ADS)
Soares, M. R.; Souza, D. N.
2011-10-01
Until the 1970s the irradiated region of a patient undergoing external beam radiotherapy was considered a homogeneous volume and a regular surface, with physical characteristics similar to water. With the improvement of medical imaging equipment, it has become possible to conduct planning in radiotherapy treatment that considers the heterogeneities and irregularities of a patient's anatomy. Consequently, such technological resources have brought greater accuracy to radiotherapy. In this study, we determined the variation in the average amount of absorbed dose on the target volume and at the point of prescription treatment by comparing the doses which were calculated in a planning system considering the patient both as a homogeneous, and as a heterogeneous medium. The results showed that when we take into account the volume of the upper vagina and cervix, and consider the pelvis as a heterogeneous medium, the calculated dose was under-estimated at some points in the studied volume with respect to the dose when this region was considered homogeneous.
Walenkamp, Monique M J; Bentohami, Abdelali; Slaar, Annelie; Beerekamp, M Suzan H; Maas, Mario; Jager, L Cara; Sosef, Nico L; van Velde, Romuald; Ultee, Jan M; Steyerberg, Ewout W; Goslings, J Carel; Schep, Niels W L
2015-12-18
Although only 39 % of patients with wrist trauma have sustained a fracture, the majority of patients is routinely referred for radiography. The purpose of this study was to derive and externally validate a clinical decision rule that selects patients with acute wrist trauma in the Emergency Department (ED) for radiography. This multicenter prospective study consisted of three components: (1) derivation of a clinical prediction model for detecting wrist fractures in patients following wrist trauma; (2) external validation of this model; and (3) design of a clinical decision rule. The study was conducted in the EDs of five Dutch hospitals: one academic hospital (derivation cohort) and four regional hospitals (external validation cohort). We included all adult patients with acute wrist trauma. The main outcome was fracture of the wrist (distal radius, distal ulna or carpal bones) diagnosed on conventional X-rays. A total of 882 patients were analyzed; 487 in the derivation cohort and 395 in the validation cohort. We derived a clinical prediction model with eight variables: age; sex, swelling of the wrist; swelling of the anatomical snuffbox, visible deformation; distal radius tender to palpation; pain on radial deviation and painful axial compression of the thumb. The Area Under the Curve at external validation of this model was 0.81 (95 % CI: 0.77-0.85). The sensitivity and specificity of the Amsterdam Wrist Rules (AWR) in the external validation cohort were 98 % (95 % CI: 95-99 %) and 21 % (95 % CI: 15 %-28). The negative predictive value was 90 % (95 % CI: 81-99 %). The Amsterdam Wrist Rules is a clinical prediction rule with a high sensitivity and negative predictive value for fractures of the wrist. Although external validation showed low specificity and 100 % sensitivity could not be achieved, the Amsterdam Wrist Rules can provide physicians in the Emergency Department with a useful screening tool to select patients with acute wrist trauma for radiography. The upcoming implementation study will further reveal the impact of the Amsterdam Wrist Rules on the anticipated reduction of X-rays requested, missed fractures, Emergency Department waiting times and health care costs. This study was registered in the Dutch Trial Registry, reference number NTR2544 on October 1(st), 2010.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murayama, Y.; Wierzbicki, J.; Bowen, M.G.
The purpose was to evaluate the feasibility and toxicity of [sup 252]Cf neutron brachytherapy combined with hyperaccelerated chemoradiotherapy for Stage III and IV cervical cancers. Eleven patients with advanced Stage IIIB-IVA cervical cancers were treated with [sup 252]Cf neutron brachytherapy in an up-front schedule followed by cisplatin (CDDP; 50 mg/m[sup 2]) chemotherapy and hyperfractionated accelerated (1.2 Gy bid) radiotherapy given concurrently with intravenous infusion of 5-Fluorouracil (5-FU) (1000 mg/m[sup 2]/day [times] 4 days) in weeks 1 and 4 with conventional radiation (weeks 2, 3, 5, and 6). Total dose at a paracervical point A isodose surface was 80-85 Gy-eq bymore » external and intracavitary therapy and 60 Gy at the pelvic sidewalls. Patients tolerated the protocol well. There was 91% compliance with the chemotherapy and full compliance with the [sup 252]Cf brachytherapy and the external beam radiotherapy. There were no problems with acute chemo or radiation toxicity. One patient developed a rectovaginal fistula (Grade 3-4 RTOG criteria) but no other patients developed significant late cystitis, proctitis or enteritis. There was complete response (CR) observed in all cases. With mean follow-up to 26 months, local control has been achieved with 90% actuarial 3-year survival with no evidence of disease (NED). [sup 252]Cf neutrons can be combined with cisplatin and 5-FU infusion chemotherapy plus hyperaccelerated chemoradiotherapy without unusual side effects or toxicity and with a high local response and tumor control rate. Further study of [sup 252]Cf neutron-chemoradiotherapy for advanced and bulky cervical cancer are indicated. The authors found chemotherapy was more effective with the improved local tumor control. 18 refs., 2 tabs.« less
Integrated Diagnostic and Treatment Devices for Enroute Critical Care of Patients within Theater
2010-04-01
are all indicated for both adult and pediatric patients, are lightweight systems designed to attach either directly to a NATO litter or attach to a...external defibrillator and blood chemistry analysis system. Figure 1: Patient Being Transported with the Life Support for Trauma and Transport...be difficult to replace or refill. The LSTAT was also designed to accept external oxygen sources. Integrated Diagnostic and Treatment Devices for
NASA Technical Reports Server (NTRS)
Turner, E. R.; Wilson, M. D.; Hylton, L. D.; Kaufman, R. M.
1985-01-01
Progress in predictive design capabilities for external heat transfer to turbine vanes was summarized. A two dimensional linear cascade (previously used to obtain vane surface heat transfer distributions on nonfilm cooled airfoils) was used to examine the effect of leading edge shower head film cooling on downstream heat transfer. The data were used to develop and evaluate analytical models. Modifications to the two dimensional boundary layer model are described. The results were used to formulate and test an effective viscosity model capable of predicting heat transfer phenomena downstream of the leading edge film cooling array on both the suction and pressure surfaces, with and without mass injection.
Air-fluidized therapy: physical properties and clinical uses.
VanGilder, Catherine; Lachenbruch, Charlie A
2010-09-01
Since the late 1960s, air-fluidized therapy (AFT) has been effectively used to treat patients with pressure ulcers, burns, and many other clinical problems. Much of the demonstrated efficacy is believed to be associated with the unique fluid environment provided by AFT that is fundamentally different from the support provided by surfaces made up of conventional solid materials. Fluid support maximizes the envelopment of the body while significantly reducing shear, friction, and pressure, and mechanical stress applied to the skin and subcutaneous tissue. Additionally, the variable temperature airflow allows the microclimate to be controlled according to needs for both therapy and patient comfort. Clinical benefits of AFT include faster and more cost-effective healing of pressure ulcers, a decreased rate of hospitalizations and emergency room visits for long-term care pressure ulcer patients, decreased mortality of patients with extensive burns and inhalation injury and rapid healing and increased comfort in burn patients. The fluid support also results in a substantial decrease in the amount of caregiver effort required for repositioning patients and increased patient comfort in patients with multiple trauma and external fixation devices or deformities that require a conforming bed, and patients with cancer and bony metastasis. This article seeks to evaluate the physical differences in AFT over other mattress types and to review the published literature for this therapy modality.
Shi, Lewis L; Cahill, Kirk E; Ek, Eugene T; Tompson, Jeffrey D; Higgins, Laurence D; Warner, Jon J P
2015-10-01
In patients with rotator cuff dysfunction, reverse shoulder arthroplasty can restore active forward flexion, but it does not provide a solution for the lack of active external rotation because of infraspinatus and the teres minor dysfunction. A modified L'Episcopo procedure can be performed in the same setting wherein the latissimus dorsi and teres major tendons are transferred to the lateral aspect of proximal humerus in an attempt to restore active external rotation. (1) Do latissimus dorsi and teres major tendon transfers with reverse shoulder arthroplasty improve external rotation function in patients with posterosuperior rotator cuff dysfunction? (2) Do patients experience less pain and have improved outcome scores after surgery? (3) What are the complications associated with reverse shoulder arthroplasty with latissimus dorsi and teres major transfer? Between 2007 and 2010, we treated all patients undergoing shoulder arthroplasty who had a profound external rotation lag sign and advanced fatty degeneration of the posterosuperior rotator cuff (infraspinatus plus teres minor) with this approach. A total of 21 patients (mean age 66 years; range, 58-82 years) were treated this way and followed for a minimum of 2 years (range, 26-81 months); none was lost to followup, and all have been seen in the last 5 years. We compared pre- and postoperative ranges of motion, pain, and functional status; scores were drawn from chart review. We also categorized major and minor complications. Active forward flexion improved from 56° ± 36° to 120° ± 38° (mean difference: 64° [95% confidence interval {CI}, 45°-83°], p < 0.001). Active external rotation with the arm adducted improved from 6° ± 16° to 38° ± 14° (mean difference: 30° [95% CI, 21°-39°], p < 0.001); active external rotation with the arm abducted improved from 19° ± 25° to 74° ± 22° (mean difference: 44° [95% CI, 22°-65°], p < 0.001). Pain visual analog score improved from 8.4 ± 2.3 to 1.7 ± 2.1 (mean difference: -6.9 [95% CI, -8.7 to -5.2], p < 0.001), and Single Assessment Numeric Evaluation score improved from 28% ± 21% to 80% ± 24% (mean difference: 46% [95% CI, 28%-64%], p < 0.001). There were six major complications, five of which were treated operatively. Overall, three patients' latissimus and teres major transfer failed based on persistent lack of external rotation. In patients with posterior and superior cuff deficiency, reverse shoulder arthroplasty combined with latissimus dorsi and teres major transfer through a single deltopectoral incision can reliably increase active forward flexion and external rotation. Patients experience pain relief and functional improvement but have a high rate of complications; therefore, we recommend the procedure be limited to patients indicated for reverse who have profound external rotation loss and a high grade of infraspinatus/teres minor fatty atrophy. Level IV, therapeutic study.
Embolomycotic Aneurysm of External Iliac Artery
Terán, Nemesio A.; Gonzalez, Nerio M.; García, Luis; Gonzalez, Freddy E.; Rivera, Humberto E.
1989-01-01
We report a case of embolomycotic aneurysm of the right iliac artery secondary to bacterial endocarditis. The patient, a 33-year-old woman, presented with unilateral hydronephrosis and lower extremity edema caused by aneurysmal compression of the ipsilateral ureter and the external iliac vein. She was treated with ligation and an extraperitoneal left-external-iliac-artery to right-femoral-artery bypass using a knitted Dacron prosthesis. Since her surgery, our patient has been well except for persistence of moderate leg edema. To the best of our knowledge, we are reporting the 1st case of embolomycotic external-iliac-artery aneurysm secondary to bacterial endocarditis and resulting in hydronephrosis and venous insufficiency. (Texas Heart Institute Journal 1989;16:51-55) Images PMID:15227238
NASA Astrophysics Data System (ADS)
Su, Peng; Khreishi, Manal A. H.; Su, Tianquan; Huang, Run; Dominguez, Margaret Z.; Maldonado, Alejandro; Butel, Guillaume; Wang, Yuhao; Parks, Robert E.; Burge, James H.
2014-03-01
A software configurable optical test system (SCOTS) based on deflectometry was developed at the University of Arizona for rapidly, robustly, and accurately measuring precision aspheric and freeform surfaces. SCOTS uses a camera with an external stop to realize a Hartmann test in reverse. With the external camera stop as the reference, a coordinate measuring machine can be used to calibrate the SCOTS test geometry to a high accuracy. Systematic errors from the camera are carefully investigated and controlled. Camera pupil imaging aberration is removed with the external aperture stop. Imaging aberration and other inherent errors are suppressed with an N-rotation test. The performance of the SCOTS test is demonstrated with the measurement results from a 5-m-diameter Large Synoptic Survey Telescope tertiary mirror and an 8.4-m diameter Giant Magellan Telescope primary mirror. The results show that SCOTS can be used as a large-dynamic-range, high-precision, and non-null test method for precision aspheric and freeform surfaces. The SCOTS test can achieve measurement accuracy comparable to traditional interferometric tests.
NASA Astrophysics Data System (ADS)
Kralkina, E. A.; Rukhadze, A. A.; Nekliudova, P. A.; Pavlov, V. B.; Petrov, A. K.; Vavilin, K. V.
2018-03-01
Present paper is aimed to reveal experimentally and theoretically the influence of magnetic field strength, antenna shape, pressure, operating frequency and geometrical size of plasma sources on the ability of plasma to absorb the RF power characterized by the equivalent plasma resistance for the case of low pressure RF inductive discharge located in the external magnetic field. The distinguishing feature of the present paper is the consideration of the antennas that generate not only current but charge on the external surface of plasma sources. It is shown that in the limited plasma source two linked waves can be excited. In case of antennas generating only azimuthal current the waves can be attributed as helicon and TG waves. In the case of an antenna with the longitudinal current there is a surface charge on the side surface of the plasma source, which gives rise to a significant increase of the longitudinal and radial components of the RF electric field as compared with the case of the azimuthal antenna current.
Plagens-Rotman, Katarzyna; Przybylska, Renata; Adamski, Zygmunt; Czarnecka-Operacz, Magdalena
2018-01-01
Introduction Lichen sclerosus et atrophicus (LSA) and an inversed type of psoriasis belong to a group of benign dermatoses usually located within the region of female external genitalia. The most common subjective symptoms reported by patients are itching, pain and changes in the color and structure of the skin. Aim This paper presents 3 cases of patients suffering from selected dermatoses located within the external female genitalia treated at the Department of Dermatology, Poznan University of Medical Sciences. Case reports Case 1. A 78-year-old patient admitted to the Department of Dermatology diagnosed with l ichen sclerosus and atrophic as well as scleroderma, which had already been confirmed by histopathological examination in 2014. Laboratory tests demonstrated an increased level of glycemia, elevated ESR and lymphopenia. In the treatment of TFX (Thymus factor X) therapy (immunomodulating treatment), vitamins A + E containing cream and Protopic 0.1% ointment twice daily were recommended. Case 2. A patient aged 49 was admitted to the Department of Dermatology due to exacerbation of skin inflammation in the course of psoriasis. She presented with severe erythematous and papular lesions covered with silvery scales, with the highest intensity within the palmar surfaces of both hands, in the folds of under the breasts, groins, and therefore, the clinical picture was characteristic of inversed psoriasis (psoriasis inversa). Case 3. A 20-year-old patient admitted to the Department of Dermatology in order to proceed with the treatment of a diffuse type of scleroderma. Clinical diagnosis has been already confirmed by the skin biopsy (typical histological features of scleroderma), however exclusion of other dermatoses such as LSA was not possible. Conclusions While analyzing the available scientific reports, the physician in charge must adjust therapeutic options individually, taking into account the clinical condition of the patient in case of dermatological diseases within the female genital region. PMID:29760622
[Arthroscopic knee arthrodesis: 4 cases].
Acquitter, Y; Hulet, C; Souquet, D; Pierre, A; Locker, B; Vielpeau, C
2004-02-01
Arthroscopic arthrodesis of the knee joint is an alternative to classical surgery, which retains a few exceptional indications. We report the first four cases of our experience, describing the technical modalities and indications. The four patients had undergone multiple operations for severe trauma. All four had persistent severe pain with a very limited walking distance. Before the procedure, the IKS score ranged from 11 to 44 and the mean function score was 20 to 45 points. Arthroscopic arthrodesis was proposed after several consultations and took into account the young age of the patient and a positive brace test. The successive arthroscopic times were: exploration and adherence release, complete extramural meniscectomy, joint surface avivement. Traction was not necessary. Careful avivement spared the anatomic curvatures of the condyles and slightly scraped out the plateaus. Finally, the arthrodesis was fixed in correct position under fluoroscopy using a single tube external fixator. The fixation was maintained until fusion (satisfactory x-ray and no pain). A drain was inserted only for the first patient. There were no cutaneous complications. Patients were discharged after 3 days on the average with immediate simulated weight bearing using two crutches. The external fixator was dynamized at two months (mean) and removed at five months. The functional gain was considerable in four patients, assessed at two years, with a mean IKS score of 75 and a mean function score of 80. The four patients walked without crutches and without pain. Single leg stance was stable. Final leg shortening was 1 to 2 cm. The arthroscopic approach provides several benefits: uneventful postoperative period, little bleeding, no cutaneous complications, shorter hospital stay. The time to fusion appears to be shorter than with classical techniques, but cannot be demonstrated clearly because of the diversity of the series reported in the literature. Arthroscopic arthrodesis does not require any special instruments, but does require surgical skill and a lengthy procedure. When arthrodesis is required the arthroscopic procedure is indicated for minimally deformed knees without major loss of bone stock.
New Model for Estimating Glomerular Filtration Rate in Patients With Cancer
Janowitz, Tobias; Williams, Edward H.; Marshall, Andrea; Ainsworth, Nicola; Thomas, Peter B.; Sammut, Stephen J.; Shepherd, Scott; White, Jeff; Mark, Patrick B.; Lynch, Andy G.; Jodrell, Duncan I.; Tavaré, Simon; Earl, Helena
2017-01-01
Purpose The glomerular filtration rate (GFR) is essential for carboplatin chemotherapy dosing; however, the best method to estimate GFR in patients with cancer is unknown. We identify the most accurate and least biased method. Methods We obtained data on age, sex, height, weight, serum creatinine concentrations, and results for GFR from chromium-51 (51Cr) EDTA excretion measurements (51Cr-EDTA GFR) from white patients ≥ 18 years of age with histologically confirmed cancer diagnoses at the Cambridge University Hospital NHS Trust, United Kingdom. We developed a new multivariable linear model for GFR using statistical regression analysis. 51Cr-EDTA GFR was compared with the estimated GFR (eGFR) from seven published models and our new model, using the statistics root-mean-squared-error (RMSE) and median residual and on an internal and external validation data set. We performed a comparison of carboplatin dosing accuracy on the basis of an absolute percentage error > 20%. Results Between August 2006 and January 2013, data from 2,471 patients were obtained. The new model improved the eGFR accuracy (RMSE, 15.00 mL/min; 95% CI, 14.12 to 16.00 mL/min) compared with all published models. Body surface area (BSA)–adjusted chronic kidney disease epidemiology (CKD-EPI) was the most accurate published model for eGFR (RMSE, 16.30 mL/min; 95% CI, 15.34 to 17.38 mL/min) for the internal validation set. Importantly, the new model reduced the fraction of patients with a carboplatin dose absolute percentage error > 20% to 14.17% in contrast to 18.62% for the BSA-adjusted CKD-EPI and 25.51% for the Cockcroft-Gault formula. The results were externally validated. Conclusion In a large data set from patients with cancer, BSA-adjusted CKD-EPI is the most accurate published model to predict GFR. The new model improves this estimation and may present a new standard of care. PMID:28686534
New Model for Estimating Glomerular Filtration Rate in Patients With Cancer.
Janowitz, Tobias; Williams, Edward H; Marshall, Andrea; Ainsworth, Nicola; Thomas, Peter B; Sammut, Stephen J; Shepherd, Scott; White, Jeff; Mark, Patrick B; Lynch, Andy G; Jodrell, Duncan I; Tavaré, Simon; Earl, Helena
2017-08-20
Purpose The glomerular filtration rate (GFR) is essential for carboplatin chemotherapy dosing; however, the best method to estimate GFR in patients with cancer is unknown. We identify the most accurate and least biased method. Methods We obtained data on age, sex, height, weight, serum creatinine concentrations, and results for GFR from chromium-51 ( 51 Cr) EDTA excretion measurements ( 51 Cr-EDTA GFR) from white patients ≥ 18 years of age with histologically confirmed cancer diagnoses at the Cambridge University Hospital NHS Trust, United Kingdom. We developed a new multivariable linear model for GFR using statistical regression analysis. 51 Cr-EDTA GFR was compared with the estimated GFR (eGFR) from seven published models and our new model, using the statistics root-mean-squared-error (RMSE) and median residual and on an internal and external validation data set. We performed a comparison of carboplatin dosing accuracy on the basis of an absolute percentage error > 20%. Results Between August 2006 and January 2013, data from 2,471 patients were obtained. The new model improved the eGFR accuracy (RMSE, 15.00 mL/min; 95% CI, 14.12 to 16.00 mL/min) compared with all published models. Body surface area (BSA)-adjusted chronic kidney disease epidemiology (CKD-EPI) was the most accurate published model for eGFR (RMSE, 16.30 mL/min; 95% CI, 15.34 to 17.38 mL/min) for the internal validation set. Importantly, the new model reduced the fraction of patients with a carboplatin dose absolute percentage error > 20% to 14.17% in contrast to 18.62% for the BSA-adjusted CKD-EPI and 25.51% for the Cockcroft-Gault formula. The results were externally validated. Conclusion In a large data set from patients with cancer, BSA-adjusted CKD-EPI is the most accurate published model to predict GFR. The new model improves this estimation and may present a new standard of care.
Qiu, Jiliang; Peng, Baogang; Tang, Yunqiang; Qian, Yeben; Guo, Pi; Li, Mengfeng; Luo, Junhang; Chen, Bin; Tang, Hui; Lu, Canliang; Cai, Muyan; Ke, Zunfu; He, Wei; Zheng, Yun; Xie, Dan; Li, Binkui; Yuan, Yunfei
2017-03-01
Purpose Early-stage hepatocellular carcinoma (E-HCC) is being diagnosed increasingly, and in one half of diagnosed patients, recurrence will develop. Thus, it is urgent to identify recurrence-related markers. We investigated the effectiveness of CpG methylation in predicting recurrence for patients with E-HCCs. Patients and Methods In total, 576 patients with E-HCC from four independent centers were sorted by three phases. In the discovery phase, 66 tumor samples were analyzed using the Illumina Methylation 450k Beadchip. Two algorithms, Least Absolute Shrinkage and Selector Operation and Support Vector Machine-Recursive Feature Elimination, were used to select significant CpGs. In the training phase, penalized Cox regression was used to further narrow CpGs into 140 samples. In the validation phase, candidate CpGs were validated using an internal cohort (n = 141) and two external cohorts (n = 191 and n =104). Results After combining the 46 CpGs selected by the Least Absolute Shrinkage and Selector Operation and the Support Vector Machine-Recursive Feature Elimination algorithms, three CpGs corresponding to SCAN domain containing 3, Src homology 3-domain growth factor receptor-bound 2-like interacting protein 1, and peptidase inhibitor 3 were highlighted as candidate predictors in the training phase. On the basis of the three CpGs, a methylation signature for E-HCC (MSEH) was developed to classify patients into high- and low-risk recurrence groups in the training cohort ( P < .001). The performance of MSEH was validated in the internal cohort ( P < .001) and in the two external cohorts ( P < .001; P = .002). Furthermore, a nomogram comprising MSEH, tumor differentiation, cirrhosis, hepatitis B virus surface antigen, and antivirus therapy was generated to predict the 5-year recurrence-free survival in the training cohort, and it performed well in the three validation cohorts (concordance index: 0.725, 0.697, and 0.693, respectively). Conclusion MSEH, a three-CpG-based signature, is useful in predicting recurrence for patients with E-HCC.
Capillary wave theory of adsorbed liquid films and the structure of the liquid-vapor interface
NASA Astrophysics Data System (ADS)
MacDowell, Luis G.
2017-08-01
In this paper we try to work out in detail the implications of a microscopic theory for capillary waves under the assumption that the density is given along lines normal to the interface. Within this approximation, which may be justified in terms of symmetry arguments, the Fisk-Widom scaling of the density profile holds for frozen realizations of the interface profile. Upon thermal averaging of capillary wave fluctuations, the resulting density profile yields results consistent with renormalization group calculations in the one-loop approximation. The thermal average over capillary waves may be expressed in terms of a modified convolution approximation where normals to the interface are Gaussian distributed. In the absence of an external field we show that the phenomenological density profile applied to the square-gradient free energy functional recovers the capillary wave Hamiltonian exactly. We extend the theory to the case of liquid films adsorbed on a substrate. For systems with short-range forces, we recover an effective interface Hamiltonian with a film height dependent surface tension that stems from the distortion of the liquid-vapor interface by the substrate, in agreement with the Fisher-Jin theory of short-range wetting. In the presence of long-range interactions, the surface tension picks up an explicit dependence on the external field and recovers the wave vector dependent logarithmic contribution observed by Napiorkowski and Dietrich. Using an error function for the intrinsic density profile, we obtain closed expressions for the surface tension and the interface width. We show the external field contribution to the surface tension may be given in terms of the film's disjoining pressure. From literature values of the Hamaker constant, it is found that the fluid-substrate forces may be able to double the surface tension for films in the nanometer range. The film height dependence of the surface tension described here is in full agreement with results of the capillary wave spectrum obtained recently in computer simulations, and the predicted translation mode of surface fluctuations reproduces to linear order in field strength an exact solution of the density correlation function for the Landau-Ginzburg-Wilson Hamiltonian in an external field.
A Comparative Study of Outcomes for Endoscopic Diverticulotomy versus External Diverticulectomy
Shahawy, Sarrah; Janisiewicz, Agnieszka M.; Annino, Don; Shapiro, Jo
2014-01-01
Objectives Current literature on the treatment of Zenker's Diverticulum (ZD) favors the use of various endoscopic procedures over external surgical techniques for patients, arguing that endoscopic approaches reduce intraoperative time and anesthesia, length of hospital stay, and days until oral diet is restarted. However, such techniques often have higher symptomatic recurrence rates and require further interventions. Because of our experience with both endoscopic diverticulotomy (ENDO) and external diverticulectomy (EXT) using the GIA-stapler, we sought to compare these two procedures in terms of in-hospital parameters, complications, return to normal diet, and rates of symptom recurrence. Study Design Case series with chart review. Setting Academic tertiary care hospital. Subjects Patients with Zenker's diverticulum who underwent surgical repair. Methods Retrospective analysis of 67 patients seen at Brigham and Women's Hospital between 1990 and 2012 with Zenker's diverticulum who underwent either an endoscopic Zenker's procedure (36) or an external stapler-assisted diverticulectomy with cricopharyngeal myotomy (31). Results Although the external stapler-assisted procedure for ZD does carry a longer intra-operative time and a slightly longer hospital stay than the endoscopic approach, it provides similar days until initiation of an oral diet and a similar incidence of post-operative complications. Further, it is superior to the endoscopic approach when one considers its much lower rate of symptomatic recurrence and need for revision procedures. Conclusion We argue that the external stapler-assisted diverticulectomy with cricopharyngeal myotomy should be considered as a viable treatment in patients who need definitive, single-session treatment for ZD, especially to prevent life-threatening aspiration pneumonia. PMID:24990870
Ma, Chuang; Deng, Qiang; Pu, Hongwei; Cheng, Xinchun; Kan, Yuhua; Yang, Jing; Yusufu, Aihemaitijiang; Cao, Li
2016-01-01
The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after 1 week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P=0.001), supination, (P=0.047) and extension (P=0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at 1 year. The plating group had a greater occurrence of wound infection (P=0.043), tendonitis, (P=0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the “gross motor” category (walking upstairs, bending over, walking 500 yards; P=0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after 1 year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries. PMID:27408765
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serkland, Darwin K.; So, Haley M.; Peake, Gregory M.
Here, we report on mode selection and tuning properties of vertical-external-cavity surface-emitting lasers (VECSELs) containing coupled semiconductor and external cavities of total length less than 1 mm. Our goal is to create narrowlinewidth (<1MHz) single-frequency VECSELs that operate near 850 nm on a single longitudinal cavity resonance and tune versus temperature without mode hops. We have designed, fabricated, and measured VECSELs with external-cavity lengths ranging from 25 to 800 μm. Lastly, we compare simulated and measured coupled-cavity mode frequencies and discuss criteria for single mode selection.
[External cephalic version after 36th week of gestationAnalysis of women´s perspective].
Wágnerová, K; Hruban, L; Janků, P
2017-01-01
Evaluation of opinions and subjective feelings of patients who have undergone an external cephalic version of a fetus in breech presentation after the 36th week of pregnancy. Observational analytic cohort study. Department of Obstetrics and Gynecology, Masaryk University, University Hospital Brno. We collected opinions and subjective evaluation from pregnant women who underwent an attempt of external cephalic version at the department of Gynecology and Obstetrics, Masaryk University in Brno in the period from 1st January 2015 to 31st December 2016 through a questionnaire. The questionnaire contained a total of 10 dichotomous, sampling, enumeration and scale questions. Questions were focused on the source and type of information on external cephalic version, expectations of the patients, evaluation of pain and feelings during the procedure and the overall impression. We also evaluated the differences between answers from patients after a successful and an unsuccessful version. In reported period 205 pregnant women underwent an attempt of external cephalic version. Procedure was successful in 105 (51.2%) cases of which 81 (77.1%) subsequently gave birth vaginally, 24 (22.9%) delivered by caesarean section, 10 (9.5%) out of all patients delivered in other hospitals. The total number of fully completed questionnaires was 187 (after a successful version 98 and 89 after an unsuccessful version). The most common source of information about the procedure was given to the patients from their gynecologists (40.5%) and doctors at the ambulance in the hospital where the patients are sent before delivery by their gynecologists (27.9%). Most mothers received mostly positive information (70.5%) - increased likelihood of vaginal delivery, high success rate, low risk to mother and child. Attitude of the gynecologists on the external cephalic version was positive in 52.6% and they recommended it. 14.4% of the patients had no fear before the procedure, 61% patients were nervous and 23% had fear. For 30.5% of the respondents was the version worse than expected. 33.7% of the patients expected that the procedure would be worse and for 35.8% of the women the procedure fulfilled their expectations. 42.2% of all patients rated the pain level on a scale from 0 (no pain) to 10 (maximum pain) in the range of 4-6 points, 28.9% evaluated the pain under 4 points and 28.9% over 6 points. Among other unpleasant feelings associated with external cephalic version were most frequently mentioned: nausea (15.9%), fear (39.8%), distress (7.5%). One-third of respondents, however, experienced no negative feelings (33.8%). 80.2% of the patients did not have any problems after the version. Out of all respondents 89.3% would undergo the procedure again and recommend it to others. Overall satisfaction rating on a scale from 0 (completely dissatisfied) to 5 (very satisfied) was 89.8% in the range from 4 to 5. When comparing the answers of patients after an external cephalic version there was no significant difference depending on the success of the version. The results show that the main source of information is given to the patients by their gynecologists and doctors in the hospital who recommend the procedure and significantly affect the attitude of patients towards external cephalic version. Fear and nervousness of the mothers is usually unfounded, most of the women evaluate the procedure positively and would recommend it to another pregnant women even in case of an unsuccessful attempt. Pain during the procedure is for most women bearable and in the overall ranking does not mean a significant problem.
Cho, Jong Ho; Kim, HoJoong; Kim, Jhingook
2012-10-01
Here, we describe an external tracheal stabilization technique used in a patient with tracheomalacia. A 56-year-old man presented with tracheomalacia due to prolonged mechanical ventilation. The malacic tracheal segment was approximately 2 cm in length. The malacic segment was covered with a silicone tube sutured in place using Prolene sutures (Ethicon, Somerville, NJ). Several anchoring sutures were placed between the tracheal mucosa and the silicone tube without violating the mucosal continuity. The patient was discharged on postoperative day 5 without complication. This method of external tracheal stabilization is a less invasive alternative for the management of this particular patient. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Arik, Atilla; Aksoy, Cemalettin; Aysev, Ayla; Akçakin, Melda
2018-04-24
The aim of this study was to establish the torsional and toe-walking profiles of children with autism spectrum disorder (ASD), and to analyze the correlations between torsion, toe-walking, autism severity score, and age. In total, 79 consecutive children with autism were examined to determine their hip rotations, thigh-foot angle, degree of toe-walking, and autism severity. Femoral and tibial torsion values, of the preschool patients, were compared statistically with age-matched controls. The hip rotation profile of the patients was similar to the normal group. Nearly a half of the patients with ASD present excessive external tibial torsion. The difference in the tibial torsion between patients and normal children was statistically significant. A weak correlation was found only between tibial torsion and the autism severity score, but no correlation was found between the other parameters. External tibial torsion is the cardinal and persistent orthopedic manifestation among patients with ASD. Toe-walking is the second most common such manifestation and is an independent orthopedic feature in these patients. External tibial torsion may potentially contribute toward the described gait abnormalities in patients with ASD.
Harada, Kiyoshi; Sato, Masaru; Omura, Ken
2004-01-01
We examined the ratio between actual maxillary distraction and the distraction of the rigid external distraction device (Rigid external distraction (RED) system) used for maxillary distraction in patients with a cleft deformity. Twelve patients were examined. The amount of maxillary advancement was measured on lateral cephalograms and divided by the activation amount on the RED system. The value obtained was represented as the distraction ratio of the maxilla to the system. The mean ratio in 10 patients with complete cleft lip, palate, and alveolus (complete cleft) was 0.24. However, the ratios in two patients with cleft lip and alveolus or soft cleft palate (incomplete cleft) were considerably higher than the mean ratios in patients with complete cleft. When the maxilla is distracted in patients with complete cleft using the RED system, the amount of activation on the system needs to be about four times the amount of planned maxillary distraction. However, the distraction ratio may be affected by the type of cleft.
Lee, Dong-Kyu; Kang, Min-Hyeok; Kim, Ji-Won; Kim, Yang-Gon; Park, Ji-Hyuk; Oh, Jae-Seop
2013-01-01
Abdominal strengthening exercises are important for stroke patients; however, there is a lack of research on therapeutic exercises for increasing abdominal muscle activity in stroke patients. We investigated the effects of non-paretic arm exercises using a tubing band on abdominal muscle activity in stroke patients. In total, 18 hemiplegic subjects (13 males, 5 females) were recruited. All subjects performed non-paretic arm exercises involving three different shoulder movements (extension, flexion, and horizontal abduction) using an elastic tubing band. Surface electromyography (EMG) signals were recorded from the rectus abdominis (RA), external oblique (EO), and internal oblique (IO) muscles bilaterally during non-paretic arm exercises. EMG activities of abdominal muscles during non-paretic arm extension and horizontal abduction were increased significantly versus shoulder flexion when subjects performed the arm exercise in a seated position. Muscle activity of the EO was significantly greater in the paretic than the non-paretic side during non-paretic arm extension and horizontal abduction. We suggest that non-paretic arm extension and horizontal abduction exercises using an elastic tubing band may be effective in increasing abdominal muscle activity.
Hosseini, Marzieh; Hosseinzadeh, Amin; Raufian, Kasra; Hedjazi, Arya
2015-12-01
Spontaneous retroperitoneal hematoma after warfarin therapy is an extremely rare event. Here, we report a 25-year-old man who was brought in to the emergency service with confusion. On arrival, the patient had hypotension, tachycardia, tachypnea, low-grade fever, and Glasgow Coma Scale score of 12. Abdominal examination revealed distention and mild tenderness in the right upper quadrant of the abdomen. The patient had a history of aortic valve replacement surgery and was on warfarin treatment at an international normalized ratio of 2.4. Our patient progressed to cardiorespiratory arrest. The resuscitation was initiated promptly. Despite all resuscitation measures, including transfusion and administration of high doses of catecholamine, the patient died of hypovolemic shock 3 hours after admission. At autopsy, the external surface of the abdominal great vessels (descending aorta and mesenteric vessels) showed scattered petechial hemorrhages without any visible site of perforation. After comprehensive exploration of the abdomen, no evidence of traumatic event was identified and the cause of internal blood loss was noted as warfarin adverse effect.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dyk, Sylvia van, E-mail: sylvia.vandyk@petermac.org; Kondalsamy-Chennakesavan, Srinivas; Schneider, Michal
Purpose: To compare measurements of the uterus and cervix obtained with magnetic resonance imaging (MRI) and transabdominal ultrasound to determine whether ultrasound can identify the brachytherapy target and be used to guide conformal brachytherapy planning and treatment for cervix cancer. Methods and Materials: Consecutive patients undergoing curative treatment with radiation therapy between January 2007 and March 2012 were included in the study. Intrauterine applicators were inserted into the uterine canal while patients were anesthetized. Images were obtained by MRI and transabdominal ultrasound in the longitudinal axis of the uterus with the applicator in treatment position. Measurements were taken at themore » anterior and posterior surface of the uterus at 2.0-cm intervals along the applicator, from the external os to the tip of the applicator. Data were analyzed using Bland Altman plots examining bias and 95% limits of agreement. Results: A total of 192 patients contributed 1668 measurements of the cervix and uterus. Mean (±SD) differences of measurements between imaging modalities at the anterior and posterior uterine surface ranged from 1.5 (±3.353) mm to 3.7 (±3.856) mm, and −1.46 (±3.308) mm to 0.47 (±3.502) mm, respectively. The mean differences were less than 3 mm in the cervix. The mean differences were less than 1.5 mm at all measurement points on the posterior surface. Conclusion: Differences in the measurements of the cervix and uterus obtained by MRI and ultrasound were within clinically acceptable limits. Transabdominal ultrasound can be substituted for MRI in defining the target volume for conformal brachytherapy treatment of cervix cancer.« less
Itokazu, Maki; Minoda, Yukihide; Ikebuchi, Mitsuhiko; Mizokawa, Shigekazu; Ohta, Yoichi; Nakamura, Hiroaki
2016-08-01
Soft tissue balancing is crucial to the success of total knee arthroplasty (TKA). To create a rectangular flexion joint gap, the rotation of the femoral component is important. The purpose of this study is to determine whether or not anatomical landmarks of the distal femoral condyles are parallel to the tibial bone cut surface in flexion. Forty-eight patients (three male and 45 female) with a mean age of 74years were examined. During the operation, we estimated the flexion joint gap with the following three techniques. 1) a three degree external cut to the posterior condylar line (MR1), 2) a parallel cut to the surgical transepicondylar axis (MR2), and 3) a parallel cut to the anatomical transepicondylar axis (MR3). The flexion joint gap was 1.1±3.0° (mean±standard deviation (SD)) in internal rotation in the case of MR1, 0.9±3.4° in internal rotation in the case of MR2, and 2.1±3.4° in external rotation in the case of MR3. An outlier (flexion joint gap >3.0°) was observed in 12 cases (25%) in MR1, 13 cases (27%) in MR2, and 15 cases (31%) in MR3. The anatomical landmarks of the distal femoral condyles are not always parallel to the tibial bone cut surface in flexion. To create a rectangular flexion joint gap, the rotation of the femoral component rotation is based not only on the anatomical landmarks but also on the ligament balance. Copyright © 2016 Elsevier B.V. All rights reserved.
MASS TRANSPORT EFFECTS ON THE KINETICS OF NITROBENZENE REDUCTION BY IRON METAL. (R827117)
To evaluate the importance of external mass transport on the overall rates of
contaminant reduction by iron metal (Fe0), we have compared measured
rates of surface reaction for nitrobenzene (ArNO2) to estimated rates
of external mass transport...
Study of etchants for corrosion-resistant metals, space shuttle external tank
NASA Technical Reports Server (NTRS)
Simmons, J. R.
1980-01-01
Acceptable etchant concentrations and application and removal procedures for etching austenitic stainless steel, nickel base alloys, and titanium alloys (annealed) employed on the external tank were formulated. The etchant solutions were to be capable of removing a minimum of 0.4 mils of surface material in less than one hour.
The footprint of the inter-decadal Pacific oscillation in Indian Ocean sea surface temperatures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Lu; Zhou, Tianjun; Dai, Aiguo
Superimposed on a pronounced warming trend, the Indian Ocean (IO) sea surface temperatures (SSTs) also show considerable decadal variations that can cause regional climate oscillations around the IO. However, the mechanisms of the IO decadal variability remain unclear. Here we perform numerical experiments using a state-of-the-art, fully coupled climate model in which the external forcings with or without the observed SSTs in the tropical eastern Pacific Ocean (TEP) are applied for 1871–2012. Both the observed timing and magnitude of the IO decadal variations are well reproduced in those experiments with the TEP SSTs prescribed to observations. Although the external forcingsmore » account for most of the warming trend, the decadal variability in IO SSTs is dominated by internal variability that is induced by the TEP SSTs, especially the Inter-decadal Pacific Oscillation (IPO). The IPO weakens (enhances) the warming of the external forcings by about 50% over the IO during IPO’s cold (warm) phase, which contributes about 10% to the recent global warming hiatus since 1999. As a result, the decadal variability in IO SSTs is modulated by the IPO-induced atmospheric adjustment through changing surface heat fluxes, sea surface height and thermocline depth.« less
The footprint of the inter-decadal Pacific oscillation in Indian Ocean sea surface temperatures
Dong, Lu; Zhou, Tianjun; Dai, Aiguo; ...
2016-02-17
Superimposed on a pronounced warming trend, the Indian Ocean (IO) sea surface temperatures (SSTs) also show considerable decadal variations that can cause regional climate oscillations around the IO. However, the mechanisms of the IO decadal variability remain unclear. Here we perform numerical experiments using a state-of-the-art, fully coupled climate model in which the external forcings with or without the observed SSTs in the tropical eastern Pacific Ocean (TEP) are applied for 1871–2012. Both the observed timing and magnitude of the IO decadal variations are well reproduced in those experiments with the TEP SSTs prescribed to observations. Although the external forcingsmore » account for most of the warming trend, the decadal variability in IO SSTs is dominated by internal variability that is induced by the TEP SSTs, especially the Inter-decadal Pacific Oscillation (IPO). The IPO weakens (enhances) the warming of the external forcings by about 50% over the IO during IPO’s cold (warm) phase, which contributes about 10% to the recent global warming hiatus since 1999. As a result, the decadal variability in IO SSTs is modulated by the IPO-induced atmospheric adjustment through changing surface heat fluxes, sea surface height and thermocline depth.« less
NASA Astrophysics Data System (ADS)
Maggio, Angelo; Carillo, Viviana; Cozzarini, Cesare; Perna, Lucia; Rancati, Tiziana; Valdagni, Riccardo; Gabriele, Pietro; Fiorino, Claudio
2013-04-01
The aim of this study was to evaluate the correlation between the ‘true’ absolute and relative dose-volume histograms (DVHs) of the bladder wall, dose-wall histogram (DWH) defined on MRI imaging and other surrogates of bladder dosimetry in prostate cancer patients, planned both with 3D-conformal and intensity-modulated radiation therapy (IMRT) techniques. For 17 prostate cancer patients, previously treated with radical intent, CT and MRI scans were acquired and matched. The contours of bladder walls were drawn by using MRI images. External bladder surfaces were then used to generate artificial bladder walls by performing automatic contractions of 5, 7 and 10 mm. For each patient a 3D conformal radiotherapy (3DCRT) and an IMRT treatment plan was generated with a prescription dose of 77.4 Gy (1.8 Gy/fr) and DVH of the whole bladder of the artificial walls (DVH-5/10) and dose-surface histograms (DSHs) were calculated and compared against the DWH in absolute and relative value, for both treatment planning techniques. A specific software (VODCA v. 4.4.0, MSS Inc.) was used for calculating the dose-volume/surface histogram. Correlation was quantified for selected dose-volume/surface parameters by the Spearman correlation coefficient. The agreement between %DWH and DVH5, DVH7 and DVH10 was found to be very good (maximum average deviations below 2%, SD < 5%): DVH5 showed the best agreement. The correlation was slightly better for absolute (R = 0.80-0.94) compared to relative (R = 0.66-0.92) histograms. The DSH was also found to be highly correlated with the DWH, although slightly higher deviations were generally found. The DVH was not a good surrogate of the DWH (R < 0.7 for most of parameters). When comparing the two treatment techniques, more pronounced differences between relative histograms were seen for IMRT with respect to 3DCRT (p < 0.0001).
Kim, Yong Hee; Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung
2010-02-01
The purpose of this study was to evaluate the safety and effectiveness of a barbed silicone-covered retrievable expandable nitinol stent in preventing stent migration in patients with tracheal strictures or fistulas. Under fluoroscopic guidance, barbed silicone-covered retrievable expandable nitinol stents were placed in 15 patients with tracheal strictures, two patients with fistulas, two patients with combined strictures and fistulas, and one patient with variable extrathoracic airway obstruction. The three pairs of barbs were attached to the external stent surface at the middle of the stent at equal intervals. Technical success, improvement in respiratory status, complications, and related interventions were evaluated. The technical success rate was 100%, and respiratory status improved or the fistula closed in all 20 patients. Complications included sputum retention (three patients), tumor overgrowth (three patients), pain (one patient), and granulation tissue formation (one patient). No stent migration occurred, even in the three patients without fixed strictures. Four stents subsequently were removed because of complications, and one stent was removed because the patient's condition improved. Stent removal was not difficult and was uneventful. The silicone membranes and barbs of the removed stents were intact. Use of a barbed silicone-covered retrievable expandable nitinol stent relieves dyspnea and facilitates fistula closure in patients with benign or malignant tracheal strictures or fistulas. The barbed design of the stent is important in preventing migration.
Metasurface external cavity laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Luyao, E-mail: luyaoxu.ee@ucla.edu; Curwen, Christopher A.; Williams, Benjamin S.
2015-11-30
A vertical-external-cavity surface-emitting-laser is demonstrated in the terahertz range, which is based upon an amplifying metasurface reflector composed of a sub-wavelength array of antenna-coupled quantum-cascade sub-cavities. Lasing is possible when the metasurface reflector is placed into a low-loss external cavity such that the external cavity—not the sub-cavities—determines the beam properties. A near-Gaussian beam of 4.3° × 5.1° divergence is observed and an output power level >5 mW is achieved. The polarized response of the metasurface allows the use of a wire-grid polarizer as an output coupler that is continuously tunable.
Apparent bandgap shift in the internal quantum efficiency for solar cells with back reflectors
NASA Astrophysics Data System (ADS)
Steiner, M. A.; Perl, E. E.; Geisz, J. F.; Friedman, D. J.; Jain, N.; Levi, D.; Horner, G.
2017-04-01
We demonstrate that in solar cells with highly reflective back mirrors, the measured internal quantum efficiency exhibits a shift in bandgap relative to the measured external quantum efficiency. The shift arises from the fact that the measured reflectance at the front surface includes a superposition of waves reflecting from the front and back surfaces. We quantify the magnitude of the apparent shift and discuss the errors that can result in determination of quantities such as the photocurrent. Because of this apparent shift, it is important the bandgap be determined from the external quantum efficiency.
Apparent bandgap shift in the internal quantum efficiency for solar cells with back reflectors
Steiner, Myles A.; Perl, E. E.; Geisz, J. F.; ...
2017-04-28
Here, we demonstrate that in solar cells with highly reflective back mirrors, the measured internal quantum efficiency exhibits a shift in bandgap relative to the measured external quantum efficiency. The shift arises from the fact that the measured reflectance at the front surface includes a superposition of waves reflecting from the front and back surfaces. We quantify the magnitude of the apparent shift and discuss the errors that can result in determination of quantities such as the photocurrent. Because of this apparent shift, it is important that the bandgap be determined from the external quantum efficiency.
Magnetic resonance elastography to observe deep areas: comparison of external vibration systems.
Suga, Mikio; Obata, Takayuki; Hirano, Masaya; Tanaka, Takashi; Ikehira, Hiroo
2007-01-01
MRE methods deform the sample using an external vibration system. We have been using a transverse driver, which generates shear waves at the object surface. One of the problems is that shear waves rapidly attenuate at the surface of tissue and do not propagate into the body. In this study, we compared the shear waves generated by transverse and longitudinal drivers. The longitudinal driver was found to induce shear waves deep inside a porcine liver phantom. These results suggest that the longitudinal driver will allow measurement of the shear modulus deep inside the body.
Heterogeneous losses of externally generated I atoms for OIL
NASA Astrophysics Data System (ADS)
Torbin, A. P.; Mikheyev, P. A.; Ufimtsev, N. I.; Voronov, A. I.; Azyazov, V. N.
2012-01-01
Usage of an external iodine atom generator can improve energy efficiency of the oxygen-iodine laser (OIL) and expand its range of operation parameters. However, a noticeable part of iodine atoms may recombine or undergo chemical bonding during transportation from the generator to the injection point. Experimental results reported in this paper showed that uncoated aluminum surfaces readily bounded iodine atoms, while nickel, stainless steel, Teflon or Plexiglas did not. Estimations based on experimental results had shown that the upper bound of probability of surface iodine atom recombination for materials Teflon, Plexiglas, nickel or stainless steel is γrec <= 10-5.
Van Voorhees, Benjamin W; Hsiung, Robert C; Marko-Holguin, Monika; Houston, Thomas K; Fogel, Joshua; Lee, Royce; Ford, Daniel E
2013-03-12
Depressive disorders and symptoms affect more than one-third of primary care patients, many of whom do not receive or do not complete treatment. Internet-based social support from peers could sustain depression treatment engagement and adherence. We do not know whether primary care patients will accept referral to such websites nor do we know which methods of referral would be most effective. We conducted a randomized clinical trial to determine whether (1) a simple generic referral card (control), (2) a patient-oriented brochure that provided examples of online postings and experience (internal motivation), or (3) a physician letter of recommendation (external motivation) would generate the greatest participation in a primary care Internet depression treatment support portal focused around an Internet support group (ISG). We used 3 offline methods to identify potential participants who had not used an ISG in the past 6 months. Eligibility was determined in part by a brief structured psychiatric interview based on the Patient Health Questionnaire-9 (PHQ-9). After consent and enrollment, participants were randomly assigned to 1 of 3 groups (control, internal motivation, or external motivation). We constructed a portal to connect primary care patients to both fact-based information and an established ISG (Psycho-Babble). The ISG allowed participants to view messages and then decide if they actually wished to register there. Participation in the portal and the ISG was assessed via automated activity tracking. Fifty participants were assigned to the 3 groups: a motivation-neutral control group (n=18), an internal motivation group (n=19), and an external motivation group (n=13). Of these participants, 31 (62%) visited the portal; 27 (54%) visited the ISG itself. The internal motivation group showed significantly greater participation than the control group on several measures. The external motivation group spent significantly less time logged onto the portal than the control group. The internal motivation group showed significantly greater participation than the external motivation group on several measures. Referral of primary care patients with depressive disorders and symptoms to an ISG is feasible even if they have never previously used one. This may best be accomplished by enhancing their internal motivation.
Ito, Kenichi; Nonaka, Koji; Ogaya, Shinya; Ogi, Atsushi; Matsunaka, Chiaki; Horie, Jun
2016-06-01
We aimed to characterize rectus abdominis, internal oblique, and external oblique muscle activity in healthy adults under expiratory resistance using surface electromyography. We randomly assigned 42 healthy adult subjects to 3 groups: 30%, 20%, and 10% maximal expiratory intraoral pressure (PEmax). After measuring 100% PEmax and muscle activity during 100% PEmax, the activity and maximum voluntary contraction of each muscle during the assigned experimental condition were measured. At 100% PEmax, the external oblique (p<0.01) and internal oblique (p<0.01) showed significantly elevated activity compared with the rectus abdominis muscle. Furthermore, at 20% and 30% PEmax, the external oblique (p<0.05 and<0.01, respectively) and the internal oblique (p<0.05 and<0.01, respectively) showed significantly elevated activity compared with the rectus abdominis muscle. At 10% PEmax, no significant differences were observed in muscle activity. Although we observed no significant difference between 10% and 20% PEmax, activity during 30% PEmax was significantly greater than during 20% PEmax (external oblique: p<0.05; internal oblique: p<0.01). The abdominal oblique muscles are the most active during forced expiration. Moreover, 30% PEmax is the minimum intensity required to achieve significant, albeit very slight, muscle activity during expiratory resistance. Copyright © 2016 Elsevier Ltd. All rights reserved.
Laceulle, Odillia M.; Van Aken, Marcel A.G.; Ormel, Johan
2017-01-01
Abstract Personality similarity between parent and offspring has been suggested to play an important role in offspring's development of externalizing problems. Nonetheless, much remains unknown regarding the nature of this association. This study aimed to investigate the effects of parent–offspring similarity at different levels of personality traits, comparing expectations based on evolutionary and goodness‐of‐fit perspectives. Two waves of data from the TRAILS study (N = 1587, 53% girls) were used to study parent–offspring similarity at different levels of personality traits at age 16 predicting externalizing problems at age 19. Polynomial regression analyses and Response Surface Analyses were used to disentangle effects of different levels and combinations of parents and offspring personality similarity. Although several facets of the offspring's personality had an impact on offspring's externalizing problems, few similarity effects were found. Therefore, there is little support for assumptions based on either an evolutionary or a goodness‐of‐fit perspective. Instead, our findings point in the direction that offspring personality, and at similar levels also parent personality might impact the development of externalizing problems during late adolescence. © 2017 The Authors. European Journal of Personality published by John Wiley & Sons Ltd on behalf of European Association of Personality Psychology PMID:28303077
Neuraxial blockade for external cephalic version: a systematic review.
Sultan, P; Carvalho, B
2011-10-01
The desire to decrease the number of cesarean deliveries has renewed interest in external cephalic version. The rationale for using neuraxial blockade to facilitate external cephalic version is to provide abdominal muscular relaxation and reduce patient discomfort during the procedure, so permitting successful repositioning of the fetus to a cephalic presentation. This review systematically examined the current evidence to determine the safety and efficacy of neuraxial anesthesia or analgesia when used for external cephalic version. A systematic literature review of studies that examined success rates of external cephalic version with neuraxial anesthesia was performed. Published articles written in English between 1945 and 2010 were identified using the Medline, Cochrane, EMBASE and Web of Sciences databases. Six, randomized controlled studies were identified. Neuraxial blockade significantly improved the success rate in four of these six studies. A further six non-randomized studies were identified, of which four studies with control groups found that neuraxial blockade increased the success rate of external cephalic version. Despite over 850 patients being included in the 12 studies reviewed, placental abruption was reported in only one patient with a neuraxial block, compared with two in the control groups. The incidence of non-reassuring fetal heart rate requiring cesarean delivery in the anesthesia groups was 0.44% (95% CI 0.15-1.32). Neuraxial blockade improved the likelihood of success during external cephalic version, although the dosing regimen that provides optimal conditions for successful version is unclear. Anesthetic rather than analgesic doses of local anesthetics may improve success. The findings suggest that neuraxial blockade does not compromise maternal or fetal safety during external cephalic version. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
Proxies and Other External Raters: Methodological Considerations
Snow, A Lynn; Cook, Karon F; Lin, Pay-Shin; Morgan, Robert O; Magaziner, Jay
2005-01-01
Objective The purpose of this paper is to introduce researchers to the measurement and subsequent analysis considerations involved when using externally rated data. We will define and describe two categories of externally rated data, recommend methodological approaches for analyzing and interpreting data in these two categories, and explore factors affecting agreement between self-rated and externally rated reports. We conclude with a discussion of needs for future research. Data Sources/Study Setting Data sources for this paper are previous published studies and reviews comparing self-rated with externally rated data. Study Design/Data Collection/Extraction Methods This is a psychometric conceptual paper. Principal Findings We define two types of externally rated data: proxy data and other-rated data. Proxy data refer to those collected from someone who speaks for a patient who cannot, will not, or is unavailable to speak for him or herself, whereas we use the term other-rater data to refer to situations in which the researcher collects ratings from a person other than the patient to gain multiple perspectives on the assessed construct. These two types of data differ in the way the measurement model is defined, the definition of the gold standard against which the measurements are validated, the analysis strategies appropriately used, and how the analyses are interpreted. There are many factors affecting the discrepancies between self- and external ratings, including characteristics of the patient, the proxy, and of the rated construct. Several psychological theories can be helpful in predicting such discrepancies. Conclusions Externally rated data have an important place in health services research, but use of such data requires careful consideration of the nature of the data and how it will be analyzed and interpreted. PMID:16179002
Physical therapy students' willingness to report misconduct to protect the patient's interests.
Mansbach, Abraham; Bachner, Yaacov G; Melzer, Itzik
2010-12-01
This article presents a study on the ethical dilemma of whistleblowing in physical therapy, and suggests some lines for further research on this topic as well as ways for integrating it in the physical therapy curriculum. The study examines the self-reported willingness of physical therapy students to report misconduct, whether internally or externally, to protect the patient's interests. Internal disclosure entails reporting the wrongdoing to an authority within the organisation. External disclosure entails reporting the offence to an outside agency, such as the police, professional organisation, or press. The findings indicate that the students view the acts that are detrimental or cause injustice to the patient in a very serious light. In dilemma situations such as these, the students reported a willingness to act. The students also report considerably greater likelihood of whistleblowing internally than externally. The pattern reveals a desire to correct the misconduct coupled with a marked decline in the willingness to blow the whistle as this act moved from the workplace to an external authority.
Landau-de Gennes theory of surface-enhanced ordering in smectic films.
Shalaginov, A N; Sullivan, D E
2001-03-01
A Landau theory for surface-enhanced ordering in smectic-A free-standing films is described, based on a generalization of de Gennes' model for a "presmectic" fluid confined between two walls. According to the theory, smectic ordering in free-standing films heated above the bulk smectic melting temperature is due to an intrinsic surface contribution rather than an external field. The theory yields a persistent finite-size effect, in that the film melting temperatures do not tend to the bulk transition temperature in the limit of infinite film thickness. It also predicts that a continuous transition from (N+1)- to N-layer films is impossible without an external field. The theory closely fits existing experimental data on layer-thinning transitions in compounds which exhibit a bulk smectic-A to nematic phase transition. Possible origins of the intrinsic surface contribution are discussed.
Microtextured Surfaces for Turbine Blade Impingement Cooling
NASA Technical Reports Server (NTRS)
Fryer, Jack
2014-01-01
Gas turbine engine technology is constantly challenged to operate at higher combustor outlet temperatures. In a modern gas turbine engine, these temperatures can exceed the blade and disk material limits by 600 F or more, necessitating both internal and film cooling schemes in addition to the use of thermal barrier coatings. Internal convective cooling is inadequate in many blade locations, and both internal and film cooling approaches can lead to significant performance penalties in the engine. Micro Cooling Concepts, Inc., has developed a turbine blade cooling concept that provides enhanced internal impingement cooling effectiveness via the use of microstructured impingement surfaces. These surfaces significantly increase the cooling capability of the impinging flow, as compared to a conventional untextured surface. This approach can be combined with microchannel cooling and external film cooling to tailor the cooling capability per the external heating profile. The cooling system then can be optimized to minimize impact on engine performance.
Method and device for removing a non-aqueous phase liquid from a groundwater system
Looney, Brian B.; Rossabi, Joseph; Riha, Brian D.
2002-01-01
A device for removing a non-aqueous phase liquid from a groundwater system includes a generally cylindrical push-rod defining an internal recess therein. The push-rod includes first and second end portions and an external liquid collection surface. A liquid collection member is detachably connected to the push-rod at one of the first and second end portions thereof. The method of the present invention for removing a non-aqueous phase liquid from a contaminated groundwater system includes providing a lance including an external hydrophobic liquid collection surface, an internal recess, and a collection chamber at the bottom end thereof. The lance is extended into the groundwater system such that the top end thereof remains above the ground surface. The liquid is then allowed to collect on the liquid collection surface, and flow downwardly by gravity into the collection chamber to be pumped upwardly through the internal recess in the lance.
The sandwich technique for repair of pectus carinatum and excavatum/carinatum complex
Kim, Kyung Soo
2016-01-01
Background Simple external compression of pectus carinatum seems to have its limitations, particularly the repair of asymmetric pectus carinatum or excavatum/carinatum complex. We devised the sandwich technique (press-molding) to remodel the entire chest wall. The purpose of this study is to introduce the sandwich technique and appraise the early results. Methods Between January 2007 and January 2016, 523 consecutive patients with pectus carinatum and its variants were analyzed retrospectively. No patients were excluded during the study period. The sandwich 1 and 2 techniques using the internal and external pectus bars were for pectus carinatum repair. Modified techniques using the external string and the internal bar were to treat the lower costal flare (the flare-buster) and focal protuberances (the magic string) in pectus excavatum repair. Statistical analyses were carried out using paired and unpaired t-test or Wilcoxon signed rank tests. Results The sandwich repair with the external and internal bars was applied to 58 pectus carinatum patients: seven symmetric (12.1%), 14 asymmetric (24.1%), and 37 carinatum-excavatum complex (63.8%). After pectus excavatum repair, 426 patients had the flare-buster and 39 patients received the magic string. The sandwich 1 technique achieved near-complete resolution of carinatum in 52 patients (86.2%). The sandwich 2 technique accomplished almost symmetric configuration with no residual carinatum in all six cases. Conclusions The sandwich technique using the external and internal bars seems to be effective in treating asymmetric pectus carinatum and complex excavatum/carinatum deformities. The flare-buster and the magic string effectively relieve the costal flare and focal protuberances in pectus excavatum repair. PMID:27747176
Zollinger, Paul E; Kreis, Robert W; van der Meulen, Hub G; van der Elst, Maarten; Breederveld, Roelf S; Tuinebreijer, Wim E
2010-02-17
Operative and conservative treatment of wrist fractures might lead to complex regional pain syndrome (CRPS) type I.In our multicenter dose response study in which patients with distal radial fractures were randomly allocated to placebo or vitamin C in a daily dose of 200mg, 500mg or 1500mg during 50 days, an operated subgroup was analyzed.48 (of 427) fractures) were operated (11.2%). Twenty-nine patients (60%) were treated with external fixation, 14 patients (29%) with K-wiring according to Kapandji and five patients (10%) with internal plate fixation. The 379 remaining patients were treated with a plaster.In the operated group of patients who received vitamin C no CRPS (0/37) was seen in comparison with one case of CRPS (Kapandji technique) in the operated group who received placebo (1/11 = 9%, p=.23). There was no CRPS after external fixation.In the conservatively treated group 17 cases of CRPS (17/379 = 4.5%) occurred in comparison with one in case of CRPS in the operated group (1/48 = 2.1%, p=.71).External fixation doesn't necessarily lead to a higher incidence of CRPS in distal radial fractures. Vitamin C may also play a role in this. This subgroup analysis in operated distal radial fractures showed no CRPS occurrence with vitamin C prophylaxis.
Shakirov, Babur M; Tagaev, Komil R; Tursunov, Bachron S; Achtamov, Dgamshed A
2009-03-01
The burn trauma of the posterior surface of calcaneus region and ankle joint followed by cicatrix formation in the Achilles tendon zone is often complicated by unhealing trophic ulcers. Eleven patients (seven men and four women, aged 9-54 years) have been operated on under our observation for prolonged unhealing ulcers and cicatrices located in the Achilles tendon zone. After cicatrices dissection, L-form plastic surgery was performed. The postoperative period was smooth; a skin graft was appropriately fixed to the proper tissues and the wound margins. Good results were achieved in 10 cases, and no complications were noted. However, in only one patient a marginal necrosis of the external talus part adjoining the ulcer due to tissue changes has been noted, but that had no influence on the good results of the operation.
On Magnetic Flux Trapping by Surface Superconductivity
NASA Astrophysics Data System (ADS)
Podolyak, E. R.
2018-03-01
The magnetic flux trapping by surface superconductivity is considered. The stability of the state localized at the cylindrical sample surface upon a change in the external magnetic field is tested. It is shown that as the magnetic field decreases, the sample acquires a positive magnetic moment due to magnetic flux trapping; i.e., the magnetization curve of surface superconductivity is "paramagnetic" by nature.
Smid, Henderikus G O M; Westenbroek, Joanna M; Bruggeman, Richard; Knegtering, Henderikus; Van den Bosch, Robert J
2009-11-30
Several theories propose that the primary cognitive impairment in schizophrenia concerns a deficit in the processing of external input information. There is also evidence, however, for impaired motor preparation in schizophrenia. This provokes the question whether the impaired motor preparation in schizophrenia is a secondary consequence of disturbed (selective) processing of the input needed for that preparation, or an independent primary deficit. The aim of the present study was to discriminate between these hypotheses, by investigating externally guided movement preparation in relation to selective stimulus processing. The sample comprised 16 recent-onset schizophrenia patients and 16 controls who performed a movement-precuing task. In this task, a precue delivered information about one, two or no parameters of a movement summoned by a subsequent stimulus. Performance measures and measures derived from the electroencephalogram showed that patients yielded smaller benefits from the precues and showed less cue-based preparatory activity in advance of the imperative stimulus than the controls, suggesting a response preparation deficit. However, patients also showed less activity reflecting selective attention to the precue. We therefore conclude that the existing evidence for an impairment of externally guided motor preparation in schizophrenia is most likely due to a deficit in selective attention to the external input, which lends support to theories proposing that the primary cognitive deficit in schizophrenia concerns the processing of input information.
Bircher, Chad; Shao, Yiping
2012-01-01
Purpose: Positron emission tomography (PET) detectors that use a dual-ended-scintillator readout to measure depth-of-interaction (DOI) must have an accurate DOI function to provide the relationship between DOI and signal ratios to be used for detector calibration and recalibration. In a previous study, the authors used a novel and simple method to accurately and quickly measure DOI function by irradiating the detector with an external uniform flood source; however, as a practical concern, implementing external uniform flood sources in an assembled PET system is technically challenging and expensive. In the current study, therefore, the authors investigated whether the same method could be used to acquire DOI function from scintillator-generated (i.e., internal) radiation. The authors also developed a method for calibrating the energy scale necessary to select the events within the desired energy window. Methods: The authors measured the DOI function of a PET detector with lutetium yttrium orthosilicate (LYSO) scintillators. Radiation events originating from the scintillators’ internal Lu-176 beta decay were used to measure DOI functions which were then compared with those measured from both an external uniform flood source and an electronically collimated external point source. The authors conducted these studies with several scintillators of differing geometries (1.5 × 1.5 and 2.0 × 2.0 mm2 cross-section area and 20, 30, and 40 mm length) and various surface finishes (mirror-finishing, saw-cut rough, and other finishes in between), and in a prototype array. Results: All measured results using internal and external radiation sources showed excellent agreement in DOI function measurement. The mean difference among DOI values for all scintillators measured from internal and external radiation sources was less than 1.0 mm for different scintillator geometries and various surface finishes. Conclusions: The internal radioactivity of LYSO scintillators can be used to accurately measure DOI function in PET detectors, regardless of scintillator geometry or surface finish. Because an external radiation source is not needed, this method of DOI function measurement can be practically applied to individual PET detectors as well as assembled systems. PMID:22320787
Bircher, Chad; Shao, Yiping
2012-02-01
Positron emission tomography (PET) detectors that use a dual-ended-scintillator readout to measure depth-of-interaction (DOI) must have an accurate DOI function to provide the relationship between DOI and signal ratios to be used for detector calibration and recalibration. In a previous study, the authors used a novel and simple method to accurately and quickly measure DOI function by irradiating the detector with an external uniform flood source; however, as a practical concern, implementing external uniform flood sources in an assembled PET system is technically challenging and expensive. In the current study, therefore, the authors investigated whether the same method could be used to acquire DOI function from scintillator-generated (i.e., internal) radiation. The authors also developed a method for calibrating the energy scale necessary to select the events within the desired energy window. The authors measured the DOI function of a PET detector with lutetium yttrium orthosilicate (LYSO) scintillators. Radiation events originating from the scintillators' internal Lu-176 beta decay were used to measure DOI functions which were then compared with those measured from both an external uniform flood source and an electronically collimated external point source. The authors conducted these studies with several scintillators of differing geometries (1.5 × 1.5 and 2.0 × 2.0 mm(2) cross-section area and 20, 30, and 40 mm length) and various surface finishes (mirror-finishing, saw-cut rough, and other finishes in between), and in a prototype array. All measured results using internal and external radiation sources showed excellent agreement in DOI function measurement. The mean difference among DOI values for all scintillators measured from internal and external radiation sources was less than 1.0 mm for different scintillator geometries and various surface finishes. The internal radioactivity of LYSO scintillators can be used to accurately measure DOI function in PET detectors, regardless of scintillator geometry or surface finish. Because an external radiation source is not needed, this method of DOI function measurement can be practically applied to individual PET detectors as well as assembled systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bircher, Chad; Shao Yiping
Purpose: Positron emission tomography (PET) detectors that use a dual-ended-scintillator readout to measure depth-of-interaction (DOI) must have an accurate DOI function to provide the relationship between DOI and signal ratios to be used for detector calibration and recalibration. In a previous study, the authors used a novel and simple method to accurately and quickly measure DOI function by irradiating the detector with an external uniform flood source; however, as a practical concern, implementing external uniform flood sources in an assembled PET system is technically challenging and expensive. In the current study, therefore, the authors investigated whether the same method couldmore » be used to acquire DOI function from scintillator-generated (i.e., internal) radiation. The authors also developed a method for calibrating the energy scale necessary to select the events within the desired energy window. Methods: The authors measured the DOI function of a PET detector with lutetium yttrium orthosilicate (LYSO) scintillators. Radiation events originating from the scintillators' internal Lu-176 beta decay were used to measure DOI functions which were then compared with those measured from both an external uniform flood source and an electronically collimated external point source. The authors conducted these studies with several scintillators of differing geometries (1.5 x 1.5 and 2.0 x 2.0 mm{sup 2} cross-section area and 20, 30, and 40 mm length) and various surface finishes (mirror-finishing, saw-cut rough, and other finishes in between), and in a prototype array. Results: All measured results using internal and external radiation sources showed excellent agreement in DOI function measurement. The mean difference among DOI values for all scintillators measured from internal and external radiation sources was less than 1.0 mm for different scintillator geometries and various surface finishes. Conclusions: The internal radioactivity of LYSO scintillators can be used to accurately measure DOI function in PET detectors, regardless of scintillator geometry or surface finish. Because an external radiation source is not needed, this method of DOI function measurement can be practically applied to individual PET detectors as well as assembled systems.« less
Meta-analysis of correlates of provider behavior in medical encounters.
Hall, J A; Roter, D L; Katz, N R
1988-07-01
This article summarizes the results of 41 independent studies containing correlates of objectively measured provider behaviors in medical encounters. Provider behaviors were grouped a priori into the process categories of information giving, questions, competence, partnership building, and socioemotional behavior. Total amount of communication was also included. All correlations between variables within these categories and external variables (patient outcome variables or patient and provider background variables) were extracted. The most frequently occurring outcome variables were satisfaction, recall, and compliance, and the most frequently occurring background variables were the patient's gender, age, and social class. Average correlations and combined significance levels were calculated for each combination of process category and external variable. Results showed significant relations of small to moderate average magnitude between these external variables and almost all of the provider behavior categories. A theory of provider-patient reciprocation is proposed to account for the pattern of results.
[Experience in treating patients with chronic obstructive bronchitis with fenspirid].
Kirichenko, A A; Shabanova, T M
2002-01-01
To study a clinical effect of fenspirid and its impact on external respiration function in patients with chronic obstructive bronchitis (COB) in the exacerbation phase. 30 COB patients participated in the trial (20 males, 10 females, age 39-80 years). The severity of clinical symptoms (cough, sputum, dyspnea) was studied using special scales. External respiration function was examined by a spirometric system "Tamrac system spiro sense Y2 14". Fenspirid treatment was conducted in a dose 80 mg twice a day for 3 months. Control examinations were made 2 weeks, 1 and 3 months after the treatment start. A 3-month treatment with fenspirid resulted in regression of COB symptoms: cough and sputum ceased, dyspnea decreased. This led to improvement in external respiration function, especially in patients with mixed ventilatory disorders with prevailing restriction. Fenspirid is an effective and well tolerated treatment of chronic obstructive bronchitis.
Miyake, H; Ohta, T; Tanaka, H
2000-02-01
The use of hydroxyapatite-based ceramics for cranioplasties has recently increased in Japan, because of the good cosmetic outcomes, biocompatibility, strength, osteoconductive properties, and lack of risk of disease transmission associated with these materials. However, miniplate fixation has not been possible for ceramic implants. We describe a new technique for miniplate fixation of ceramic implants. Combination ceramic implants composed of hydroxyapatite and tricalcium phosphate (Ceratite; NGK Spark Plug Co., Aichi, Japan) were used for cranioplasties. A slot and a pair of holes were cut in each Ceratite implant, for use as a fixation unit. We have also developed a new L-shaped titanium plate (HOMS Engineering Inc., Nagano, Japan) that fits into the fixation unit. We first insert an L-shaped titanium plate through the slot from the back surface of the Ceratite implant. We then bend the plate outward at the front surface of the Ceratite implant and fix it to the cranium of the patient with titanium screws. The Ceratite implant is usually firmly fixed to the cranium of the patient with three L-shaped titanium plates. Using L-shaped titanium plates and Ceratite implants, we successfully performed cranioplasties for seven patients with cranial defects resulting from external decompression craniotomies. The Ceratite implant exactly fit the bone window for each patient. Surgical maneuvers were simple and easy for all patients, permitting shorter operating times. All Ceratite implants were firmly fixed, and no postoperative infections have occurred. Our new technique for cranioplasty is simple and allows rigid fixation of Ceratite implants.
Lyu, Honghong; Gao, Bin; He, Feng; Zimmerman, Andrew R; Ding, Cheng; Huang, Hua; Tang, Jingchun
2018-02-01
With the goal of combining the advantages of ball-milling and biochar technologies, a variety of ball-milled biochars (BM-biochars) were synthesized, characterized, and tested for nickel (Ni(II)) removal from aqueous solution. Ball milling increased only the external surface area of low temperature biochars, but still dramatically enhanced their ability to sorb aqueous Ni(II). For higher temperature biochars with relatively low surface area, ball milling increased both external and internal surface area. Measurements of pH, zeta potential, stability, and Boehm titration demonstrated that ball milling also added oxygen-containing functional groups (e.g., carboxyl, lactonic, and hydroxyl) to biochar's surface. With these changed, all the BM-biochars showed much better Ni(II) removal efficiency than unmilled biochars. Ball-milled 600 °C bagasse biochar (BMBG600) showed the greatest Ni(II) adsorption capacity (230-650 compared to 26-110 mmol/kg for unmilled biochar) and the adsorption was dosage and pH dependent. Compared with the unmilled biochar, BMBG600 also displayed faster adsorption kinetics, likely due to an increase in rates of intra-particle diffusion in the latter. Experimental and modeling results suggest that the increase in BM-biochar's external and internal surface areas exposed its graphitic structure, thus enhancing Ni(II) adsorption via strong cation-π interaction. In addition, the increase in acidic surface functional groups enhanced Ni(II) adsorption by BM-biochar via electrostatic interaction and surface complexation. Ball milling thus has great potential to increase the efficiency of environmentally friendly biochar for various environmental applications. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dental hygiene student experiences in external placements in Australia.
Taylor, Jane A; Hayes, Melanie J; Wallace, Linda
2012-05-01
While placements in external locations are being increasingly used in dental education globally, few studies have explored the student learning experience at such placements. The purpose of this study was to investigate student experiences while on external placement in a baccalaureate dental hygiene program. A self-reporting questionnaire was distributed to final-year dental hygiene students (n=77) at the University of Newcastle, Australia, in 2010. The questionnaire included questions regarding the type of placement, experiences offered, supervision, resources available, and lasting impressions. Responding students were generally positive about their external placement experience and indicated that the majority of facilities provided them with the opportunity to provide direct patient care and perform clinical tasks typical of a practicing hygienist. However, there was a statistically significant difference in their opinions about discipline-focused and community placements. Students indicated that their external placement experience provided opportunities to learn more about time and patient management, including hands-on experience with specific clinical tasks. Ongoing evaluations are necessary to ensure that external placements meet both student needs and intended learning outcomes within dental hygiene programs.
Trappe, Hans-Joachim
2016-03-01
In Germany approximately 70,000-100,000 SCD patients die from sudden cardiac death (SCD). SCD is not caused by a single factor but is a multifactorial problem. In 50 % of SCD victims, sudden cardiac death is the first manifestation of heart disease. SCD is caused by ventricular tachyarrhythmias in approximately 90 % of patients, whereas SCD is caused by bradyarrhythmias in 5-10 % of the patients. Risk stratification is not possible in the majority of them prior to the fatal event. Early defibrillation is the method of choice to terminate ventricular fibrillation. Therefore, it is mandatory to install automatic external defibrillators (AED) in places with many people. There is general agreement that early defibrillation with automated external defibrillators (AED) is an effective tool to treat patients with ventricular fibrillation and will improve survival. It seems necessary to teach cardiocompression and AED use, also to children and adolescents. AED therapy "at home" did not improve survival in patients with cardiac arrest and can not be recommended.
Effect of coating on properties of esthetic orthodontic nickel-titanium wires.
Iijima, Masahiro; Muguruma, Takeshi; Brantley, William; Choe, Han-Cheol; Nakagaki, Susumu; Alapati, Satish B; Mizoguchi, Itaru
2012-03-01
To determine the effect of coating on the properties of two esthetic orthodontic nickel-titanium wires. Woowa (polymer coating; Dany Harvest) and BioForce High Aesthetic Archwire (metal coating; Dentsply GAC) with cross-section dimensions of 0.016 × 0.022 inches were selected. Noncoated posterior regions of the anterior-coated Woowa and uncoated Sentalloy were used for comparison. Nominal coating compositions were determined by x-ray fluorescence (JSX-3200, JOEL). Cross-sectioned and external surfaces were observed with a scanning electron microscope (SEM; SSX-550, Shimadzu) and an atomic force microscope (SPM-9500J2, Shimadzu). A three-point bending test (12-mm span) was carried out using a universal testing machine (EZ Test, Shimadzu). Hardness and elastic modulus of external and cross-sectioned surfaces were obtained by nanoindentation (ENT-1100a, Elionix; n = 10). Coatings on Woowa and BioForce High Aesthetic Archwire contained 41% silver and 14% gold, respectively. The coating thickness on Woowa was approximately 10 µm, and the coating thickness on BioForce High Aesthetic Archwire was much smaller. The surfaces of both coated wires were rougher than the noncoated wires. Woowa showed a higher mean unloading force than the noncoated Woowa, although BioForce High Aesthetic Archwire showed a lower mean unloading force than Sentalloy. While cross-sectional surfaces of all wires had similar hardness and elastic modulus, values for the external surface of Woowa were smaller than for the other wires. The coating processes for Woowa and BioForce High Aesthetic Archwire influence bending behavior and surface morphology.
Zhang, Y; Li, D D; Chen, X W
2017-06-20
Objective: Case-control study analysis of the speech discrimination of unilateral microtia and external auditory canal atresia patients with normal hearing subjects in quiet and noisy environment. To understand the speech recognition results of patients with unilateral external auditory canal atresia and provide scientific basis for clinical early intervention. Method: Twenty patients with unilateral congenital microtia malformation combined external auditory canal atresia, 20 age matched normal subjects as control group. All subjects used Mandarin speech audiometry material, to test the speech discrimination scores (SDS) in quiet and noisy environment in sound field. Result: There's no significant difference of speech discrimination scores under the condition of quiet between two groups. There's a statistically significant difference when the speech signal in the affected side and noise in the nomalside (single syllable, double syllable, statements; S/N=0 and S/N=-10) ( P <0.05). There's no significant difference of speech discrimination scores when the speech signal in the nomalside and noise in the affected side. There's a statistically significant difference in condition of the signal and noise in the same side when used one-syllable word recognition (S/N=0 and S/N=-5) ( P <0.05), while double syllable word and statement has no statistically significant difference ( P >0.05). Conclusion: The speech discrimination scores of unilateral congenital microtia malformation patients with external auditory canal atresia under the condition of noise is lower than the normal subjects. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.
Charged Vaidya solution satisfies weak energy condition
NASA Astrophysics Data System (ADS)
Chatterjee, Soumyabrata; Ganguli, Suman; Virmani, Amitabh
2016-07-01
The external matter stress-tensor supporting charged Vaidya solution appears to violate weak energy condition in certain region of the spacetime. Motivated by this, a new interpretation of charged Vaidya solution was proposed by Ori (Class Quant Grav 8:1559, 1991) in which the energy condition continues to be satisfied. In this construction, one glues an outgoing Vaidya solution to the original ingoing Vaidya solution provided the surface where the external stress-tensor vanishes is spacelike. We revisit this study and extend it to higher-dimensions, to AdS settings, and to higher-derivative f( R) theories. In asymptotically flat space context, we explore in detail the case when the mass function m( v) is proportional to the charge function q( v). When the proportionality constant ν = q(v)/m(v) lies in between zero and one, we show that the surface where the external stress-tensor vanishes is spacelike and lies in between the inner and outer apparent horizons.
Hail damage on Atlantis' external tank is inspected
2007-04-13
In the Vehicle Assembly Building, markers show the hail damage being repaired on the external tank of Space Shuttle Atlantis. The white hole with a red circle around it is a hole prepared for molding and material application. The red material is sealant tape so the mold doesn't leak when the foam rises against the mold. The white/ translucent square mold is an area where the foam has been applied and the foam has risen and cured against the mold surface. The area will be de-molded and sanded flush with the adjacent area. In late February, Atlantis' external tank received hail damage during a severe thunderstorm that passed through the Kennedy Space Center Launch Complex 39 area. The hail caused visible divots in the giant tank's foam insulation as well as minor surface damage to about 26 heat shield tiles on the shuttle's left wing. The launch now is targeted for June 8.
NASA Astrophysics Data System (ADS)
Booth, Adam M.; McCarley, Justin; Hinkle, Jason; Shaw, Susan; Ampuero, Jean-Paul; Lamb, Michael P.
2018-05-01
Landslides reactivate due to external environmental forcing or internal mass redistribution, but the process is rarely documented quantitatively. We capture the three-dimensional, 1-m resolution surface deformation field of a transiently reactivated landslide with image correlation of repeat airborne lidar. Undrained loading by two debris flows in the landslide's head, rather than external forcing, triggered reactivation. After that loading, the lower 2 km of the landslide advanced by up to 14 m in 2 years before completely stopping. The displacement field over those 2 years implies that the slip surface gained 1 kPa of shear strength, which was likely accomplished by a negative dilatancy-pore pressure feedback as material deformed around basal roughness elements. Thus, landslide motion can be decoupled from external environmental forcing in cases, motivating the need to better understand internal perturbations to the stress field to predict hazards and sediment fluxes as landscapes evolve.
Exogenous chemicals enter organisms through critical surfaces in the lung, gills, gut, and skin. Transfer across these boundaries is the first step in characterizing the ratio of tissue dose to external exposure. Surface processes and fugacity are important elements of both human...
Development of a passive sampler for gaseous mercury
NASA Astrophysics Data System (ADS)
Gustin, M. S.; Lyman, S. N.; Kilner, P.; Prestbo, E.
2011-10-01
Here we describe work toward development of the components of a cost effective passive sampling system for gaseous Hg that could be broadly deployed by nontechnical staff. The passive sampling system included an external shield to reduce turbulence and exposure to precipitation and dust, a diffusive housing that directly protects the collection surface during deployment and handling, and a collection surface. A protocol for cleaning and deploying the sampler and an analytical method were developed. Our final design consisted of a polycarbonate external shield enclosing a custom diffusive housing made from expanded PTFE tubing. Two collection surfaces were investigated, gold sputter-coated quartz plates and silver wires. Research showed the former would require extensive quality control for use, while the latter had interferences with other atmosphere constituents. Although the gold surface exhibited the best performance over space and time, gradual passivation would limit reuse. For both surfaces lack of contamination during shipping, deployment and storage indicated that the handling protocols developed worked well with nontechnical staff. We suggest that the basis for this passive sampling system is sound, but further exploration and development of a reliable collection surface is needed.
Miniature modular microwave end-to-end receiver
NASA Technical Reports Server (NTRS)
Sukamto, Lin M. (Inventor); Cooley, Thomas W. (Inventor); Janssen, Michael A. (Inventor); Parks, Gary S. (Inventor)
1993-01-01
An end-to-end microwave receiver system contained in a single miniature hybrid package mounted on a single heatsink is presented. It includes an input end connected to a microwave receiver antenna and an output end which produces a digital count proportional to the amplitude of a signal of a selected microwave frequency band received at the antenna and corresponding to one of the water vapor absorption lines near frequencies of 20 GHz or 30 GHz. The hybrid package is on the order of several centimeters in length and a few centimeters in height and width. The package includes an L-shaped carrier having a base surface, a vertical wall extending up from the base surface and forming a corner therewith, and connection pins extending through the vertical wall. Modular blocks rest on the base surface against the vertical wall and support microwave monolithic integrated circuits on top surfaces thereof connected to the external connection pins. The modular blocks lie end-to-end on the base surface so as to be modularly removable by sliding along the base surface beneath the external connection pins away from the vertical wall.
Thermal radiation scanning tunnelling microscopy
NASA Astrophysics Data System (ADS)
de Wilde, Yannick; Formanek, Florian; Carminati, Rémi; Gralak, Boris; Lemoine, Paul-Arthur; Joulain, Karl; Mulet, Jean-Philippe; Chen, Yong; Greffet, Jean-Jacques
2006-12-01
In standard near-field scanning optical microscopy (NSOM), a subwavelength probe acts as an optical `stethoscope' to map the near field produced at the sample surface by external illumination. This technique has been applied using visible, infrared, terahertz and gigahertz radiation to illuminate the sample, providing a resolution well beyond the diffraction limit. NSOM is well suited to study surface waves such as surface plasmons or surface-phonon polaritons. Using an aperture NSOM with visible laser illumination, a near-field interference pattern around a corral structure has been observed, whose features were similar to the scanning tunnelling microscope image of the electronic waves in a quantum corral. Here we describe an infrared NSOM that operates without any external illumination: it is a near-field analogue of a night-vision camera, making use of the thermal infrared evanescent fields emitted by the surface, and behaves as an optical scanning tunnelling microscope. We therefore term this instrument a `thermal radiation scanning tunnelling microscope' (TRSTM). We show the first TRSTM images of thermally excited surface plasmons, and demonstrate spatial coherence effects in near-field thermal emission.
NASA Astrophysics Data System (ADS)
Berland, K.; Einstein, T. L.; Hyldgaard, P.
2012-01-01
The response of the Cu(111) Shockley surface state to an external electrical field is characterized by combining a density-functional theory calculation for a slab geometry with an analysis of the Kohn-Sham wave functions. Our analysis is facilitated by a decoupling of the Kohn-Sham states via a rotation in Hilbert space. We find that the surface state displays isotropic dispersion, quadratic until the Fermi wave vector but with a significant quartic contribution beyond. We calculate the shift in energetic position and effective mass of the surface state for an electrical field perpendicular to the Cu(111) surface; the response is linear over a broad range of field strengths. We find that charge transfer occurs beyond the outermost copper atoms and that accumulation of electrons is responsible for a quarter of the screening of the electrical field. This allows us to provide well converged determinations of the field-induced changes in the surface state for a moderate number of layers in the slab geometry.
Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian; Wiebking, Ulrich; Hankemeier, Stefan
2011-09-01
Bone transport can be performed with an external fixator alone or with the monorail technique which entails the combination of a fixator and an intramedullary nail. The purpose of this study was to compare the complication rates and long-term outcomes of these methods. Two groups of patients, the external fixator (n = 21) and the monorail group (n = 18), were compared. The average follow-up period was 7.9 ± 5.6 years and the mean defect length 8.3 ± 3.1 cm. Healing was achieved in 19 (90%) and 13 (72%) of the fixator and monorail patients, respectively. Six patients underwent amputations because of persistent infections (two in the fixator and four in the monorail group). The rate of deformities was significantly higher in the fixator group (p = 0.049). No statistically significant difference was found when comparing categories of the SF-36 test or the ability to work or do sports. The main advantages of the monorail method are reduction of the external fixation time and the lower rate of deformities. However, the authors recommend segmental transport with external fixator in patients with chronic infections.
Hui, Jennifer I; Shriver, Erin M; Tse, David T
2011-01-01
To describe a stent placement method that eliminates stent prolapse in external dacryocystorhinostomy. A retrospective, institutional review board- approved case series of patients undergoing external dacryocystorhinostomy with an alternative stenting method. Following anastomosis of the posterior flaps, one arm of a Crawford silicone stent is passed through each canaliculus. Both arms are then passed through the nasolacrimal duct and retrieved in the inferior meatus. The 2 distal arms are redirected in the nose; one arm is looped around the proximal portions within the lacrimal sac and tied to the second arm. The stent is self-linked around the inferior turbinate. Nine patients underwent external dacryocystorhinostomy with alternative stenting. None experienced postoperative stent prolapse. At last follow-up (average, 38 months; range, 5-102 months), 8 patients reported resolution of tearing and exhibited normal dye clearance. On compression of the lacrimal sac, none of these 8 patients exhibited reflux of stagnant tears or dye through the canaliculi. This alternative method improves stent retention by using the inferior turbinate as a stopper to eliminate stent prolapse. The self-linking nature obviates the need and expense of additional biomedical devices.
[Outpatient external dacryocystorhinostomy under regional anesthesia and sedation].
Benatar-Haserfaty, J; Monleón de la Calle, M P; Sanz-López, A; Muriel García, A
2007-01-01
To assess the rate of early complications of outpatient external dacryocystorhinostomy (DCR) and patient satisfaction with the anesthetic technique. This prospective study enrolled 58 patients undergoing external DCR. We analyzed demographic variables, ASA physical status, level of sedation achieved, postoperative pain, systemic complications, intraoperative bleeding, duration of surgery, time until discharge home, and patient and surgeon satisfaction with the anesthetic technique. The mean (SD) level of satisfaction was 4.85 (0.80) points on the Iowa Satisfaction With Anesthesia Scale (ISAS). A positive association was found between postoperative pain and a lower ISAS score. There was also a positive association between use of rescue analgesia in the early postoperative period and a lower ISAS score. Mean blood loss per procedure was 178.9 (108.2) mL. The rate of minor systemic complications was 15.5%. The surgeon's rating of conditions in the surgical field was excellent or good in 89.6% of the cases. External DCR can be performed on an outpatient basis within a reasonable safety margin and with a low early postoperative complication rate. Patient satisfaction with anesthesia was high. Provision of preoperative information about the meaning of sedation, postoperative analgesia, and surgical bleeding are aspects to improve in this practice setting.
Source monitoring in Korsakoff's syndrome: "Did I touch the toothbrush or did I imagine doing so?"
El Haj, Mohamad; Nandrino, Jean Louis; Coello, Yann; Miller, Ralph; Antoine, Pascal
2017-06-01
There is a body of research suggesting compromised ability to distinguish between different external sources of information (i.e., external monitoring) in Korsakoff's syndrome. Here we replicate and extend this literature by assessing the ability of patients with Korsakoff's syndrome to distinguish between different external sources of information (i.e., external monitoring), between internal and external sources of information (i.e., reality monitoring), and between different internal sources of information (i.e., internal monitoring). On the external monitoring assessment, patients with Korsakoff's syndrome and controls watched the experimenter place objects (e.g., a toothbrush) in either a black or white box; afterward, they were asked to remember where the objects had been placed. On the reality monitoring assessment, participants had to either place objects or watch the experimenter place objects in a black box; afterward, they were asked to remember whether the objects had been placed in the box by themselves or by the experimenter. On the internal monitoring assessment, participants had to either place objects or imagine themselves placing objects in a black box; afterward, they were asked to remember whether they had previously placed the objects in the box or imagined doing so. Analyses demonstrated lower external and internal monitoring in patients with Korsakoff's syndrome than in controls, but no significant difference was observed between the two populations on the reality monitoring condition. Our data provide preliminary evidence that the ability to recognize oneself as the author of one's own actions may be relatively preserved in Korsakoff's syndrome. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wu, Gang; Luo, Xiaozhong; Tan, Lun; Lin, Xu; Wu, Chao; Guo, Yong; Zhong, Zewei
2013-11-01
To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P > 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P > 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (Chi(2)=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 versus 13.0% and 0 versus 8.7%, P > 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (Chi(2)=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P < 0.05). The LCP external fixator can obtain reliable fixation in treating tibial open fracture, and has good patients' compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.
Akatov YuA; Arkhangelsky, V V; Kovalev, E E; Spurny, F; Votochkova, I
1989-01-01
In this paper we present absorbed dose measurements with glass thermoluminescent detectors on external surface of satellites of Kosmos-serie flying in 1983-87. Experiments were performed with thermoluminescent aluminophosphate glasses of thicknesses 0.1, 0.3, 0.4, 0.5, and 1 mm. They were exposed in sets of total thickness between 5 and 20 mm, which were protected against sunlight with thin aluminized foils. In all missions, extremely high absorbed dose values were observed in the first layers of detectors, up to the thickness of 0.2 to 0.5 gcm-2. These experimental results confirm that, during flights at 250 to 400 km, doses on the surface of the satellites are very high, due to the low energy component of the proton and electron radiation.
Whelan, Daniel B; Kletke, Stephanie N; Schemitsch, Geoffrey; Chahal, Jaskarndip
2016-02-01
The recurrence rate after primary anterior shoulder dislocation is high, especially in young, active individuals. Recent studies have suggested external rotation immobilization as a method to reduce the rate of recurrent shoulder dislocation in comparison to traditional sling immobilization. To assess and summarize evidence from randomized controlled trials on the effect of internal rotation versus external rotation immobilization on the rate of recurrence after primary anterior shoulder dislocation. Meta-analysis. PubMed, MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, and abstracts from recent proceedings were searched for eligible studies. Two reviewers selected studies for inclusion, assessed methodological quality, and extracted data. Six randomized controlled trials (632 patients) were included in this review. Demographic and prognostic variables measured at baseline were similar in the pooled groups. The average age was 30.1 years in the pooled external rotation group and 30.3 years in the pooled internal rotation group. Two studies found that external rotation immobilization reduced the rate of recurrence after initial anterior shoulder dislocation compared with conventional internal rotation immobilization, whereas 4 studies failed to find a significant difference between the 2 groups. This meta-analysis suggested no overall significant difference in the rate of recurrence among patients treated with internal rotation versus external rotation immobilization (risk ratio, 0.69; 95% CI, 0.42-1.14; P = .15). There was no significant difference in the rate of compliance between internal and external rotation immobilization (P = .43). The Western Ontario Shoulder Instability Index scores were pooled across 3 studies, and there was no significant difference between the 2 groups (P = .54). Immobilization in external rotation is not significantly more effective in reducing the recurrence rate after primary anterior shoulder dislocation than immobilization in internal rotation. Additionally, this review suggests that there is minimal difference in patients' perceptions of their health-related quality of life after immobilization in internal versus external rotation. © 2015 The Author(s).
External-beam irradiation of carcinoma of the penis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sagerman, R.H.; Yu, W.S.; Chung, C.T.
1984-07-01
Twenty-four patients with biopsy-proved squamous-cell carcinoma of the penis underwent external-beam radiation therapy between 1966 and 1980. Fifteen were treated for the primary tumor and 9 for metastatic inguinal lymphadenopathy; no patient received prophylactic nodal irradiation. Seven out of 9 tumors in stage I, 2/3 in stage II, and 1/3 in stage IV were controlled for three years. Control of fixed, inoperable groin nodes was poor, and none of these patients survived beyond 1 1/2 years.
Double Versus Single Tendon Transfers to Improve Shoulder Function in Brachial Plexus Birth Palsy.
Greenhill, Dustin A; Smith, William R; Ramsey, F V; Kozin, Scott H; Zlotolow, Dan A
2017-03-27
In children with brachial plexus birth palsy (BPBP) undergoing tendon transfers to augment shoulder external rotation, it is unclear whether transfer of the latissimus dorsi with its combined latissimus dorsi and teres major (cLT) versus isolated teres major (iTM) tendon transfer yield different outcomes. Records of patients with BPBP who underwent shoulder tendon transfers to augment external rotation were retrospectively reviewed. Transfer type (cLT or iTM) was considered indiscriminate by virtue of surgeon preference. Modified Mallet Scale (mMS) and Active Movement Scale scores were recorded. Patients with <12 months' follow-up, C7 or lower palsy, humeral osteotomy, shoulder procedure(s) within 8 months, microsurgery within 1 year, or recurrent glenohumeral subluxation confirmed by postoperative imaging were excluded. Matched cohorts were identified within each tendon transfer group to yield similar preoperative shoulder function and glenohumeral alignment status. Outcomes for all tendon transfers as well as differences between cLT and iTM cohorts were analyzed. Among 121 cLT and 34 iTM transfers, 49 cLT and 14 iTM met the inclusion criteria. Subsequent matching of cohorts yielded 28 patients (14 cLT and 14 iTM). Average age at time of transfer was 3.0±1.4 years. Follow-up averaged 4.1±3.1 years. There were no statistically significant preoperative differences between cohorts, thus matching criteria were validated. Regardless of tendon(s) transferred, mMS external rotation improved (2.2 to 3.5, P<0.001), whereas mMS internal rotation decreased (3.8 to 3.2, P<0.001). When comparing matched cohorts, cLT transfer produced a greater mMS external rotation improvement than iTM (2.1 vs. 1.5, respectively; P=0.025). Loss of midline function (defined as mMS external rotation <3) occurred in 5 (35.7%) cLT and 2 (14.3%) iTM patients. Both cLT or iTM transfer are effective at augmenting shoulder external rotation in children with C5-C6 BPBP. Furthermore, cLT transfers may yield a larger improvement in external rotation in certain patients. However, both techniques slightly decrease shoulder internal rotation. Given that more total cLT patients lost midline function among matched cohorts, iTM transfer may still be considered when limited midline function is a concern. Level III.
Code of Federal Regulations, 2010 CFR
2010-10-01
... hull barge with internal framing 1 Double hull barge with external framing 2 Single hull barge with..., ends, and bottoms) when the structural framing is on the internal tank surface. 2 Applicable to double hull tank barges (double sides, ends, and bottoms) when the structural framing is on the external tank...
Tic-Tac: Accelerating a Skateboard from Rest without Touching an External Support
ERIC Educational Resources Information Center
Kunesch, M.; Usunov, A.
2010-01-01
This paper outlines the solution that the Team of Austria found to problem number 7, "skateboarder", presented in the finals of the 22nd International Young Physicists' Tournament (IYPT) in Tianjin, China. We investigated how a skateboarder can accelerate from rest on a horizontal surface without touching an external support. The focus was laid on…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-23
... inspecting the fuselage surface for corrosion and cracking behind the external adapter plate of the antennae... external adapter plate of the antennae during inspection. Similar cracking was found on two additional... antennae of certain damage-tolerant structure, which could result in reduced structural integrity and...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-19
... surface for corrosion and cracking behind the external adapter plate of the antennae installation, and... plate of the antennae during inspection. Similar cracking was found on two additional airplanes, and... cracking behind the external adapter plate of the antennae of certain safe-life structure, which could...
10 CFR 71.51 - Additional requirements for Type B packages.
Code of Federal Regulations, 2014 CFR
2014-01-01
... sensitivity of 10−6 A2 per hour, no significant increase in external surface radiation levels, and no substantial reduction in the effectiveness of the packaging; and (2) Section 71.73 (“Hypothetical accident... radioactive material exceeding a total amount A2 in 1 week, and no external radiation dose rate exceeding 10 m...
10 CFR 71.51 - Additional requirements for Type B packages.
Code of Federal Regulations, 2012 CFR
2012-01-01
... sensitivity of 10−6 A2 per hour, no significant increase in external surface radiation levels, and no substantial reduction in the effectiveness of the packaging; and (2) Section 71.73 (“Hypothetical accident... radioactive material exceeding a total amount A2 in 1 week, and no external radiation dose rate exceeding 10 m...
10 CFR 71.51 - Additional requirements for Type B packages.
Code of Federal Regulations, 2013 CFR
2013-01-01
... sensitivity of 10−6 A2 per hour, no significant increase in external surface radiation levels, and no substantial reduction in the effectiveness of the packaging; and (2) Section 71.73 (“Hypothetical accident... radioactive material exceeding a total amount A2 in 1 week, and no external radiation dose rate exceeding 10 m...
10 CFR 71.51 - Additional requirements for Type B packages.
Code of Federal Regulations, 2011 CFR
2011-01-01
... sensitivity of 10−6 A2 per hour, no significant increase in external surface radiation levels, and no substantial reduction in the effectiveness of the packaging; and (2) Section 71.73 (“Hypothetical accident... radioactive material exceeding a total amount A2 in 1 week, and no external radiation dose rate exceeding 10 m...
10 CFR 71.51 - Additional requirements for Type B packages.
Code of Federal Regulations, 2010 CFR
2010-01-01
... sensitivity of 10−6 A2 per hour, no significant increase in external surface radiation levels, and no substantial reduction in the effectiveness of the packaging; and (2) Section 71.73 (“Hypothetical accident... radioactive material exceeding a total amount A2 in 1 week, and no external radiation dose rate exceeding 10 m...
Rothenberger, Jens; Krauss, Sabrina; Held, Manuel; Bender, Dominik; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Constantinescu, Mihai Adrian; Jaminet, Patrick
2014-11-01
Pressure ulcers are associated with severe impairment for the patients and high economic load. With this study we wanted to gain more insight to the skin perfusion dynamics due to external loading. Furthermore, we evaluated the effect of different types of pressure relief mattresses. A total of 25 healthy volunteers were enrolled in the study. Perfusion dynamics of the sacral and the heel area were assessed using the O2C-device, which combines a laser light, to determine blood flow, and white light to determine the relative amount of hemoglobin. Three mattresses were evaluated compared to a hard surface: a standard hospital foam mattress bed, a visco-elastic foam mattress, and an air-fluidized bed. In the heel area, only the air-fluidized bed was able to maintain the blood circulation (mean blood flow of 13.6 ± 6 versus 3.9 ± 3 AU and mean relative amount of hemoglobin of 44.0 ± 14 versus 32.7 ± 12 AU.) In the sacral area, all used mattresses revealed an improvement of blood circulation compared to the hard surface. The results of this study form a more precise pattern of perfusion changes due to external loading on various pressure relief mattresses. This knowledge may reduce the incidence of pressure ulcers and may be an influencing factor in pressure relief mattress selection. Copyright © 2014 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Prediction of Erectile Function Following Treatment for Prostate Cancer
Alemozaffar, Mehrdad; Regan, Meredith M.; Cooperberg, Matthew R.; Wei, John T.; Michalski, Jeff M.; Sandler, Howard M.; Hembroff, Larry; Sadetsky, Natalia; Saigal, Christopher S.; Litwin, Mark S.; Klein, Eric; Kibel, Adam S.; Hamstra, Daniel A.; Pisters, Louis L.; Kuban, Deborah A.; Kaplan, Irving D.; Wood, David P.; Ciezki, Jay; Dunn, Rodney L.; Carroll, Peter R.; Sanda, Martin G.
2013-01-01
Context Sexual function is the health-related quality of life (HRQOL) domain most commonly impaired after prostate cancer treatment; however, validated tools to enable personalized prediction of erectile dysfunction after prostate cancer treatment are lacking. Objective To predict long-term erectile function following prostate cancer treatment based on individual patient and treatment characteristics. Design Pretreatment patient characteristics, sexual HRQOL, and treatment details measured in a longitudinal academic multicenter cohort (Prostate Cancer Outcomes and Satisfaction With Treatment Quality Assessment; enrolled from 2003 through 2006), were used to develop models predicting erectile function 2 years after treatment. A community-based cohort (community-based Cancer of the Prostate Strategic Urologic Research Endeavor [CaPSURE]; enrolled 1995 through 2007) externally validated model performance. Patients in US academic and community-based practices whose HRQOL was measured pretreatment (N = 1201) underwent follow-up after prostatectomy, external radiotherapy, or brachytherapy for prostate cancer. Sexual outcomes among men completing 2 years’ follow-up (n = 1027) were used to develop models predicting erectile function that were externally validated among 1913 patients in a community-based cohort. Main Outcome Measures Patient-reported functional erections suitable for intercourse 2 years following prostate cancer treatment. Results Two years after prostate cancer treatment, 368 (37% [95% CI, 34%–40%]) of all patients and 335 (48% [95% CI, 45%–52%]) of those with functional erections prior to treatment reported functional erections; 531 (53% [95% CI, 50%–56%]) of patients without penile prostheses reported use of medications or other devices for erectile dysfunction. Pretreatment sexual HRQOL score, age, serum prostate-specific antigen level, race/ethnicity, body mass index, and intended treatment details were associated with functional erections 2 years after treatment. Multivariable logistic regression models predicting erectile function estimated 2-year function probabilities from as low as 10% or less to as high as 70% or greater depending on the individual’s pretreatment patient characteristics and treatment details. The models performed well in predicting erections in external validation among CaPSURE cohort patients (areas under the receiver operating characteristic curve, 0.77 [95% CI, 0.74–0.80] for prostatectomy; 0.87 [95% CI, 0.80–0.94] for external radiotherapy; and 0.90 [95% CI, 0.85–0.95] for brachytherapy). Conclusion Stratification by pretreatment patient characteristics and treatment details enables prediction of erectile function 2 years after prostatectomy, external radiotherapy, or brachytherapy for prostate cancer. PMID:21934053
Bray, Benjamin D; Campbell, James; Cloud, Geoffrey C; Hoffman, Alex; James, Martin; Tyrrell, Pippa J; Wolfe, Charles D A; Rudd, Anthony G
2014-11-01
Case mix adjustment is required to allow valid comparison of outcomes across care providers. However, there is a lack of externally validated models suitable for use in unselected stroke admissions. We therefore aimed to develop and externally validate prediction models to enable comparison of 30-day post-stroke mortality outcomes using routine clinical data. Models were derived (n=9000 patients) and internally validated (n=18 169 patients) using data from the Sentinel Stroke National Audit Program, the national register of acute stroke in England and Wales. External validation (n=1470 patients) was performed in the South London Stroke Register, a population-based longitudinal study. Models were fitted using general estimating equations. Discrimination and calibration were assessed using receiver operating characteristic curve analysis and correlation plots. Two final models were derived. Model A included age (<60, 60-69, 70-79, 80-89, and ≥90 years), National Institutes of Health Stroke Severity Score (NIHSS) on admission, presence of atrial fibrillation on admission, and stroke type (ischemic versus primary intracerebral hemorrhage). Model B was similar but included only the consciousness component of the NIHSS in place of the full NIHSS. Both models showed excellent discrimination and calibration in internal and external validation. The c-statistics in external validation were 0.87 (95% confidence interval, 0.84-0.89) and 0.86 (95% confidence interval, 0.83-0.89) for models A and B, respectively. We have derived and externally validated 2 models to predict mortality in unselected patients with acute stroke using commonly collected clinical variables. In settings where the ability to record the full NIHSS on admission is limited, the level of consciousness component of the NIHSS provides a good approximation of the full NIHSS for mortality prediction. © 2014 American Heart Association, Inc.
Borer, Joseph G; Strakosha, Ruth; Bauer, Stuart B; Diamond, David A; Pennison, Melanie; Rosoklija, Ilina; Khoshbin, Shahram
2014-05-01
Concern in patients with bladder exstrophy after reconstruction regarding potential injury to pelvic neurourological anatomy and a resultant functional deficit prompted combined (simultaneous) cystometrography and electromyography after complete primary repair of bladder exstrophy. We determined whether complete primary repair of bladder exstrophy would adversely affect the innervation controlling bladder and external urethral sphincter function. Complete primary repair of bladder exstrophy was performed via a modified Mitchell technique in newborns without osteotomy. Postoperative evaluation included combined cystometrography and needle electrode electromyography via the perineum, approximating the external urethral sphincter muscle complex. Electromyography was done to evaluate the external urethral sphincter response to sacral reflex stimulation and during voiding. Nine boys and 4 girls underwent combined cystometrography/electromyography after complete primary repair of bladder exstrophy. Age at study and time after complete primary repair of bladder exstrophy was 3 months to 10 years (median 11.5 months). Cystometrography revealed absent detrusor overactivity and the presence of a sustained detrusor voiding contraction in all cases. Electromyography showed universally normal individual motor unit action potentials of biphasic pattern, amplitude and duration. The external urethral sphincter sacral reflex response was intact with a normal caliber with respect to Valsalva, Credé, bulbocavernosus and anocutaneous (bilateral) stimulation. Synergy was documented by abrupt silencing of external urethral sphincter electromyography activity during voiding. After complete primary repair of bladder exstrophy combined cystometrography/electromyography in patients with bladder exstrophy showed normal neurourological findings, including sacral reflex responses, sustained detrusor voiding contraction and synergic voiding, in all patients postoperatively. These findings confirm the safety of complete primary repair of bladder exstrophy. Based on our results we have discontinued routine electromyography in these patients. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhen, Xin; Chen, Jiawei; Zhong, Zichun; Hrycushko, Brian; Zhou, Linghong; Jiang, Steve; Albuquerque, Kevin; Gu, Xuejun
2017-11-01
Better understanding of the dose-toxicity relationship is critical for safe dose escalation to improve local control in late-stage cervical cancer radiotherapy. In this study, we introduced a convolutional neural network (CNN) model to analyze rectum dose distribution and predict rectum toxicity. Forty-two cervical cancer patients treated with combined external beam radiotherapy (EBRT) and brachytherapy (BT) were retrospectively collected, including twelve toxicity patients and thirty non-toxicity patients. We adopted a transfer learning strategy to overcome the limited patient data issue. A 16-layers CNN developed by the visual geometry group (VGG-16) of the University of Oxford was pre-trained on a large-scale natural image database, ImageNet, and fine-tuned with patient rectum surface dose maps (RSDMs), which were accumulated EBRT + BT doses on the unfolded rectum surface. We used the adaptive synthetic sampling approach and the data augmentation method to address the two challenges, data imbalance and data scarcity. The gradient-weighted class activation maps (Grad-CAM) were also generated to highlight the discriminative regions on the RSDM along with the prediction model. We compare different CNN coefficients fine-tuning strategies, and compare the predictive performance using the traditional dose volume parameters, e.g. D 0.1/1/2cc, and the texture features extracted from the RSDM. Satisfactory prediction performance was achieved with the proposed scheme, and we found that the mean Grad-CAM over the toxicity patient group has geometric consistence of distribution with the statistical analysis result, which indicates possible rectum toxicity location. The evaluation results have demonstrated the feasibility of building a CNN-based rectum dose-toxicity prediction model with transfer learning for cervical cancer radiotherapy.
Zhen, Xin; Chen, Jiawei; Zhong, Zichun; Hrycushko, Brian; Zhou, Linghong; Jiang, Steve; Albuquerque, Kevin; Gu, Xuejun
2017-10-12
Better understanding of the dose-toxicity relationship is critical for safe dose escalation to improve local control in late-stage cervical cancer radiotherapy. In this study, we introduced a convolutional neural network (CNN) model to analyze rectum dose distribution and predict rectum toxicity. Forty-two cervical cancer patients treated with combined external beam radiotherapy (EBRT) and brachytherapy (BT) were retrospectively collected, including twelve toxicity patients and thirty non-toxicity patients. We adopted a transfer learning strategy to overcome the limited patient data issue. A 16-layers CNN developed by the visual geometry group (VGG-16) of the University of Oxford was pre-trained on a large-scale natural image database, ImageNet, and fine-tuned with patient rectum surface dose maps (RSDMs), which were accumulated EBRT + BT doses on the unfolded rectum surface. We used the adaptive synthetic sampling approach and the data augmentation method to address the two challenges, data imbalance and data scarcity. The gradient-weighted class activation maps (Grad-CAM) were also generated to highlight the discriminative regions on the RSDM along with the prediction model. We compare different CNN coefficients fine-tuning strategies, and compare the predictive performance using the traditional dose volume parameters, e.g. D 0.1/1/2cc , and the texture features extracted from the RSDM. Satisfactory prediction performance was achieved with the proposed scheme, and we found that the mean Grad-CAM over the toxicity patient group has geometric consistence of distribution with the statistical analysis result, which indicates possible rectum toxicity location. The evaluation results have demonstrated the feasibility of building a CNN-based rectum dose-toxicity prediction model with transfer learning for cervical cancer radiotherapy.
Zhou, J; Fang, L; Xie, H; Yao, W X; Zhou, X; Xiong, Z J
2015-12-01
During radiotherapy for breast cancer, patients are greatly affected by pain, infection, and delayed healing of wounds caused by radiodermatitis. In the present study, we aimed to determine the efficacy of Liu-He-Dan in treating radiodermatitis. In 26 breast cancer patients who experienced moist decrustation while receiving radiotherapy, 5 g Liu-He-Dan was applied externally once daily after the wound surface had been cleaned and dried. The healing time was recorded, and a Kaplan-Meier survival curve was applied to analyze the treatment course. Meanwhile, a pain assessment using the Numeric Rating Scale (nrs) recorded the pain level experienced by patients after application of the Liu-He-Dan. After application of Liu-He-Dan, the average healing time for the surface of the moist decrustation wounds was 14.17 ± 2.03 days (range: 5-22 days). Inflammatory seepage decreased significantly and exudation almost disappeared in 3 days. The pain trend line indicated that the average nrs score declined with treatment in all patients. The average nrs scores at days 1, 4, and 7 were 6.13, 3.62, and 2.58 respectively. After 3 days of treatment, pain was remarkably alleviated in 80.76% of patients. After treatment for 1 week, the pain remission rate was 96.15%, without any obvious adverse reactions. Liu-He-Dan was efficacious in treating radiation skin injury with little toxicity and few side effects; the economic efficiency of the treatment was also favourable. The Liu-He-Dan was generally well tolerated by patients. In future, randomized control trials will be established for further observation of the value of Liu-He-Dan in treating radiodermatitis in breast cancer.
McDonald, Louise M.; Griffin, Harry J.; Angeli, Aikaterini; Torkamani, Mariam; Georgiev, Dejan; Jahanshahi, Marjan
2015-01-01
Background Paradoxical kinesis has been observed in bradykinetic people with Parkinson’s disease. Paradoxical kinesis occurs in situations where an individual is strongly motivated or influenced by relevant external cues. Our aim was to induce paradoxical kinesis in the laboratory. We tested whether the motivation of avoiding a mild electric shock was sufficient to induce paradoxical kinesis in externally-triggered and self-initiated conditions in people with Parkinson’s disease tested on medication and in age-matched controls. Methods Participants completed a shock avoidance behavioural paradigm in which half of the trials could result in a mild electric shock if the participant did not move fast enough. Half of the trials of each type were self-initiated and half were externally-triggered. The criterion for avoiding shock was a maximum movement time, adjusted according to each participant’s performance on previous trials using a staircase tracking procedure. Results On trials with threat of shock, both patients with Parkinson’s disease and controls had faster movement times compared to no potential shock trials, in both self-initiated and externally-triggered conditions. The magnitude of improvement of movement time from no potential shock to potential shock trials was positively correlated with anxiety ratings. Conclusions When motivated to avoid mild electric shock, patients with Parkinson’s disease, similar to healthy controls, showed significant speeding of movement execution. This was observed in both self-initiated and externally-triggered versions of the task. Nevertheless, in the ET condition the improvement of reaction times induced by motivation to avoid shocks was greater for the PD patients than controls, highlighting the value of external cues for movement initiation in PD patients. The magnitude of improvement from the no potential shock to the potential shock trials was associated with the threat-induced anxiety. This demonstration of paradoxical kinesis in the laboratory under both self-initiated and externally-triggered conditions has implications for motivational and attentional enhancement of movement speed in Parkinson’s disease. PMID:26284366
Integrated external and interstitial radiation therapy for primary carcinoma of the vagina
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puthawala, A.; Syed, A.M.; Nalick, R.
1983-09-01
Twenty-seven patients with the diagnosis of primary carcinoma of the vagina were treated by definitive radiotherapy. Twenty-three patients received a combination of external and interstitial iridium-192 implant irradiation and four patients received only interstitial irradiation. Twenty-one patients had squamous cell carcinoma and six had adenocarcinoma. All patients were staged according to the FIGO classification. More than 70% of patients had relatively advanced local disease and conventional intracavitary irradiation was unsuitable. Local tumor control was observed in 85% (23 of 27 patients), and 56% of the patients remain alive and free of disease for a median follow-up period of 50 monthsmore » to a maximum follow-up period of 84 months. Fifteen percent of the patients suffered from treatment-related complications.« less
Functional outcome after the Hoffer procedure.
Murabit, Amera; Gnarra, Maria; O'Grady, Kathleen; Morhart, Michael; Olson, Jaret L
2013-06-01
Children with obstetrical brachial plexus injury often develop an internal rotation and adduction contracture about the shoulder as a secondary deformity, resulting in an inability to externally rotate and abduct the shoulder. The Hoffer procedure is evaluated for its potential benefit in improving shoulder abduction and external rotation and its impact on activities of daily living. This is a retrospective review of patients treated in brachial plexus injury clinic who underwent tendon transfer procedures about the shoulder. Preoperative and postoperative active movement and active range of motion were measured and recorded using the Mallet scale and the Active Movement Scale. Twenty patients were included in the study. Average age at time of surgery was 6.35 years. Thirteen patients had primary brachial plexus reconstructive surgery and four patients had concomitant wrist extension tendon transfer procedures. All patients had full passive range of motion preoperatively. The average follow-up period was 25.45 months. Average differences in pre-Hoffer and post-Hoffer Mallet scale scores are as follows: active abduction, 1.20; external rotation, 1.35; hand-to-neck, 1.25; hand-to-back, 0.75; hand-to-mouth, 0.65; and aggregate score, 5.20 (p<0.001 for all). Average differences in relevant pre-Hoffer and post-Hoffer Active Movement Scale scores are as follows: shoulder abduction, 2.10; shoulder external rotation, 4.25; and shoulder internal rotation, -0.80. All patients maintained full range of motion passively; thus, no functional loss was experienced. These results showed very high statistical significance (p<0.001 for all) and clinical significance. Younger patients (≤6 years) and those with better preoperative shoulder flexion and shoulder internal rotation yielded better postoperative results. The Hoffer procedure provides clinically and statistically significant improvement in external rotation and abduction while preserving functional internal rotation range in the child with obstetrical brachial plexus palsy and secondary shoulder deformity. Therapeutic, IV.
High-energy fractures of the tibial plateau. Knee function after longer follow-up.
Weigel, Dennis P; Marsh, J Lawrence
2002-09-01
Studies of the long-term outcomes of treatment of fractures of the tibial plateau have included wide mixtures of fracture types and mostly low-energy split and split-depression fractures. The long-term results of treatment of high-energy intra-articular proximal tibial fractures are unknown. The purpose of this study was to assess the function of the knee and the development of arthrosis at a minimum of five years after injury in a consecutive series of patients in whom a high-energy fracture of the tibial plateau had been treated with a uniform technique of external fixation. Between July 1988 and December 1994, thirty patients with a total of thirty-one fractures of the tibial plateau were treated with a monolateral external fixator and limited internal fixation of the articular surface. Follow-up data on twenty-four knees in twenty-three patients were obtained at a mean of ninety-eight months. Twenty patients (twenty knees) returned specifically for the study, at which time they completed an Iowa Knee Score questionnaire and a Short Form-36 (SF-36) general health survey, a physical examination was performed, and weight-bearing radiographs were made. The results of the SF-36 evaluations for fourteen patients and the Knee Scores for twelve were compared with those obtained five years previously, at two to four years after the injury. After healing, no patient required a secondary reconstructive procedure. The range of motion of the knee averaged 3 degrees of extension to 120 degrees flexion, which was an average of 87% of the total arc of the contralateral knee. The average Iowa Knee Score was 90 points (range, 72 to 100 points). For twelve patients, the Iowa Knee Score previously recorded at two to four years averaged 92 points, as did the score at the time of the latest follow-up. Thirteen patients rated their outcome as excellent; six, as good; and three, as fair. Fifteen patients were working, and ten of them were performing strenuous labor. Radiographs showed no evidence of arthrosis in fourteen knees, grade-1 arthrosis in three, grade-2 in three, and grade-3 in two. Compared with the radiographic appearance two to four years after injury, there was no evidence of progression of arthrosis in eighteen knees and one grade of progression in four. The SF-36 subscale scores were similar to those of age-matched controls. The fourteen patients who had previous SF-36 scores had no deterioration of these scores. Patients with a high-energy fracture of the tibial plateau treated with external fixation have a good prognosis for satisfactory knee function in the second five years after injury. The knee joint cartilage appears to be tolerant of both the injury and mild-to-moderate residual articular displacement, which was associated with a low rate of severe arthrosis.
Prediction of Success in External Cephalic Version under Tocolysis: Still a Challenge.
Vaz de Macedo, Carolina; Clode, Nuno; Mendes da Graça, Luís
2015-01-01
External cephalic version is a procedure of fetal rotation to a cephalic presentation through manoeuvres applied to the maternal abdomen. There are several prognostic factors described in literature for external cephalic version success and prediction scores have been proposed, but their true implication in clinical practice is controversial. We aim to identify possible factors that could contribute to the success of an external cephalic version attempt in our population. We retrospectively examined 207 consecutive external cephalic version attempts under tocolysis conducted between January 1997 and July 2012. We consulted the department's database for the following variables: race, age, parity, maternal body mass index, gestational age, estimated fetal weight, breech category, placental location and amniotic fluid index. We performed descriptive and analytical statistics for each variable and binary logistic regression. External cephalic version was successful in 46.9% of cases (97/207). None of the included variables was associated with the outcome of external cephalic version attempts after adjustment for confounding factors. We present a success rate similar to what has been previously described in literature. However, in contrast to previous authors, we could not associate any of the analysed variables with success of the external cephalic version attempt. We believe this discrepancy is partly related to the type of statistical analysis performed. Even though there are numerous prognostic factors identified for the success in external cephalic version, care must be taken when counselling and selecting patients for this procedure. The data obtained suggests that external cephalic version should continue being offered to all eligible patients regardless of prognostic factors for success.
Benifla, J L; Goffinet, F; Darai, E; Madelenat, P
1994-12-01
Transabdominal amnioinfusion can be used to facilitate external cephalic version. Our technique involves filling the uterine cavity with 700 or 900 mL of 37C saline under continuous echographic monitoring. External cephalic version is done the next morning. We have used this procedure in six women, all of whom had previous unsuccessful attempts at external cephalic version. After amnioinfusion, all six patients were converted to cephalic presentation and delivered normally, without obstetric or neonatal complications.
Spatially Synchronous Extinction of Species under External Forcing
NASA Astrophysics Data System (ADS)
Amritkar, R. E.; Rangarajan, Govindan
2006-06-01
More than 99% of the species that ever existed on the surface of the Earth are now extinct and their extinction on a global scale has been a puzzle. One may think that a species under an external threat may survive in some isolated locations leading to the revival of the species. Using a general model we show that, under a common external forcing, the species with a quadratic saturation term first undergoes spatial synchronization and then extinction. The effect can be observed even when the external forcing acts only on some locations provided the dynamics contains a synchronizing term. Absence of the quadratic saturation term can help the species to avoid extinction.
Rana, Surinder Singh; Bhasin, Deepak Kumar; Nanda, Mohit; Siyad, Ismail; Gupta, Rajesh; Kang, Mandeep; Nagi, Birinder; Singh, Kartar
2010-06-01
External pancreatic fistulas (EPFs) are a therapeutic challenge. The present study was conducted to evaluate the efficacy of endoscopic transpapillary nasopancreatic drainage (NPD) in patients with EPF. Over 12 years, 23 patients (19 males) with EPF underwent attempted endoscopic transpapillary NPD. The end points were fistula closure with healing of pancreatic duct disruption on nasopancreatogram, or need for surgery. All 23 patients had persistent drain output (>50 mL/day) for >6 weeks. The mean output volume of the fistula was 223 mL (range: 60 mL to 750 mL). Sixteen patients had partial and seven patients had complete pancreatic duct disruption. The NPD could be successfully placed in 21/23 (91.3%) patients. Disruption was bridged in 15 of 16 patients with partial duct disruption. EPF healed in 2-8 weeks of placement of NPD in all of the patients with partial duct disruption that was bridged and there was no recurrence at a mean follow-up of 38 months. The EPF resolved in only 2/6 (33%) patients with complete duct disruption. External pancreatic fistulas developing following percutaneous drainage of pancreatic fluid collections or surgical necrosectomy can be effectively treated by transpapillary nasopancreatic drain placement especially when there is partial ductal disruption and the disruption can be bridged.
Side-sloped surfaces substantially affect lower limb running kinematics.
Damavandi, Mohsen; Eslami, Mansour; Pearsall, David J
2017-03-01
Running on side-sloped surfaces is a common obstacle in the environment; however, how and to what extent the lower extremity kinematics adapt is not well known. The purpose of this study was to determine the effects of side-sloped surfaces on three-dimensional kinematics of hip, knee, and ankle during stance phase of running. Ten healthy adult males ran barefoot along an inclinable runway in level (0°) and side-sloped (10° up-slope and down-slope inclinations, respectively) configurations. Right hip, knee, and ankle angles along with their time of occurrence were analysed using repeated measures MANOVA. Up-slope hip was more adducted (p = 0.015) and internally rotated (p = 0.030). Knee had greater external rotations during side-sloped running at heel-strike (p = 0.005), while at toe-off, it rotated externally and internally during up-slope and down-slope running, respectively (p = 0.001). Down-slope ankle had greatest plantar flexion (p = 0.001). Up-slope ankle had greatest eversion compared with down-slope (p = 0.043), while it was more externally rotated (p = 0.030). These motion patterns are necessary to adjust the lower extremity length during side-sloped running. Timing differences in the kinematic events of hip adduction and external rotation, and ankle eversion were observed (p = 0.006). Knowledge on these alterations is a valuable tool in adopting strategies to enhance performance while preventing injury.
Alar batten cartilage graft: treatment of internal and external nasal valve collapse.
Cervelli, Valerio; Spallone, Diana; Bottini, J Davide; Silvi, Erminia; Gentile, Pietro; Curcio, Beniamino; Pascali, Michele
2009-07-01
The aim of this study was to describe the efficacy of alar batten graft in correcting internal and external nasal valve collapse (i.n.v. and e.n.v.) and evaluate the functional and aesthetic results. From July 2006 to September 2008, 80 patients (54 females and 26 males) underwent alar batten cartilage grafting. The patients were divided into three groups: (1) 55 patients with iatrogenic nasal valve collapse (80% i.n.v., 20% e.n.v.), (2) 15 patients with posttraumatic nasal valve collapse (45% i.n.v., 55% e.n.v.), and (3) 10 patients with congenital nasal valve collapse (100% e.n.v.). Patients were evaluated at 6, 12, 24, and some at 36 months after surgery. The final follow-up was at least 24 months. The results of this study revealed a significant increase in the size of the aperture at the internal or external nasal valve after the application of alar batten grafts. All the patients noted improvement in their nasal airway breathing and in their cosmetic appearance. No major complication was observed. The alar batten graft is a simple, versatile technique for long-term reshaping, repositioning, and reconstruction of the nasal valve collapse.
SU-F-T-151: Measurement Evaluation of Skin Dose in Scanning Proton Beam Therapy for Breast Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, J; Nichols, E; Strauss, D
Purpose: To measure the skin dose and compare it with the calculated dose from a treatment planning system (TPS) for breast cancer treatment using scanning proton beam therapy (SPBT). Methods: A single en-face-beam SPBT plan was generated by a commercial TPS for two breast cancer patients. The treatment volumes were the entire breasts (218 cc and 1500 cc) prescribed to 50.4 Gy (RBE) in 28 fractions. A range shifter of 5 cm water equivalent thickness was used. The organ at risk (skin) was defined to be 5 mm thick from the surface. The skin doses were measured in water withmore » an ADCL calibrated parallel plate (PP) chamber. The measured data were compared with the values calculated in the TPS. Skin dose calculations can be subject to uncertainties created by the definition of the external contour and the limitations of the correction based algorithms, such as proton convolution superposition. Hence, the external contours were expanded by 0, 3 mm and 1 cm to include additional pixels for dose calculation. In addition, to examine the effects of the cloth gown on the skin dose, the skin dose measurements were conducted with and without gown. Results: On average the measured skin dose was 4% higher than the calculated values. At deeper depths, the measured and calculated doses were in better agreement (< 2%). Large discrepancy occur for the dose calculated without external expansion due to volume averaging. The addition of the gown only increased the measured skin dose by 0.4%. Conclusion: The implemented TPS underestimated the skin dose for breast treatments. Superficial dose calculation without external expansion would result in large errors for SPBT for breast cancer.« less
Henseler, Jan Ferdinand; Nagels, Jochem; Nelissen, Rob G H H; de Groot, Jurriaan H
2014-04-01
The purpose of this study is to evaluate the muscle activity with surface electromyography (EMG) and the clinical outcome of the latissimus dorsi transfer. It remains unclear whether the clinical results of the latissimus dorsi transfer for massive posterosuperior rotator cuff tears are achieved either by active muscle contractions or by a passive tenodesis effect of the transfer. Eight patients were evaluated preoperatively and at 1 year (SD, 0.1) after the latissimus dorsi transfer. Clinical evaluation of outcomes included active range of motion, Constant score, and visual analog scale (VAS) for pain and activities of daily living (ADL). Muscle activity was recorded with EMG during directional isometric abduction and adduction tasks. The external rotation in adduction improved from 23° to 51° (P = .03). The external rotation in abduction improved from 10° to 70° (P = .02). The mean Constant score improved from 39 to 62 postoperatively (P = .01). The VAS for pain at rest improved from 3.3 preoperatively to 0.1 (P = .02). The VAS for ADL improved from 4.9 to 2.3 (P = .05). The transferred latissimus dorsi remained active in all cases, as reflected by increased latissimus dorsi EMG activity during abduction tasks. In addition, the latissimus dorsi EMG activity shifted from preoperative antagonistic co-activation in adduction to synergistic activation in abduction. The latissimus dorsi has synergistic muscle activity after transfer. Apart from a tenodesis effect, directional muscle activity seems relevant for improved clinical outcome and pain relief. A specific gain was observed for external rotation in elevated arm positions, a motion essential for ADL tasks. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Oshtrakh, M. I.; Yakovlev, G. A.; Grokhovsky, V. I.; Semionkin, V. A.
2016-12-01
Re-examination of Dronino iron meteorite and products of its weathering in the internal and external surface layers was carried out using Mössbauer spectroscopy with a high velocity resolution. New results showed the presence of α-Fe(Ni, Co), α 2-Fe(Ni, Co) and γ-Fe(Ni, Co) phases with variations in Ni concentration in Dronino metallic iron alloy. The surface weathering products were supposed as magnetite and/or maghemite, goethite with different particles size and probably ferrihydrite in the internal layer and goethite with different particles size and probably ferrihydrite in the external layer.
1300 nm optically pumped quantum dot spin vertical external-cavity surface-emitting laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alharthi, S. S., E-mail: ssmalh@essex.ac.uk; Henning, I. D.; Adams, M. J.
We report a room temperature optically pumped Quantum Dot-based Spin-Vertical-External-Cavity Surface-Emitting laser (QD Spin-VECSEL) operating at the telecom wavelength of 1.3 μm. The active medium was composed of 5 × 3 QD layers; each threefold group was positioned at an antinode of the standing wave of the optical field. Circularly polarized lasing in the QD-VECSEL under Continuous-Wave optical pumping has been realized with a threshold pump power of 11 mW. We further demonstrate at room temperature control of the QD-VECSEL output polarization ellipticity via the pump polarization.
Magnetic mesoporous Fe/carbon aerogel structures with enhanced arsenic removal efficiency.
Lin, Yi-Feng; Chen, Jia-Ling
2014-04-15
Wastewater treatment has drawn significant research attention due to its associated environmental issues. Adsorption is a promising method for treating wastewater. The development of an adsorbent with a high surface area is important. Therefore, we successfully developed mesoporous Fe/carbon aerogel (CA) structures with high specific surface areas of 48 7m(2)/g via the carbonization of composite Fe3O4/phenol-formaldehyde resin structures, which were prepared using a hydrothermal process with the addition of phenol. The mesoporous Fe/CA structures were further used for the adsorption of arsenic ions with a maximum arsenic-ion uptake of calculated 216.9 mg/g, which is higher than that observed for other arsenic adsorbents. Ferromagnetic behavior was observed for the as-prepared mesoporous Fe/CA structures with an excellent response to applied external magnetic fields. As a result, the adsorbent Fe/CA structures can be easily separated from the solution using an external magnetic field. This study develops the mesoporous Fe/CA structures with high specific surface areas and an excellent response to an applied external magnetic field to provide a feasible approach for wastewater treatment including the removal of arsenic ions. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ren, Zhenhua; Zeng, Xiantao; Liu, Hanlong; Zhou, Fengjun
2013-03-01
The application of fiber reinforced plastic (FRP), including carbon FRP and glass FRP, for structural repair and strengthening has grown due to their numerous advantages over conventional materials such as externally bonded reinforcement (EBR) and near-surface mounted (NSM) strengthening techniques. This paper summarizes the results from 21 reinforced concrete beams strengthened with different methods, including externally-bonded and near-surface mounted FRP, to study the strain coordination of the FRP and steel rebar of the RC beam. Since there is relative slipping between the RC beam and the FRP, the strain of the FRP and steel rebar of the RC beam satisfy the quasi-plane-hypothesis; that is, the strain of the longitudinal fiber that parallels the neutral axis of the plated beam within the scope of the effective height ( h 0) of the cross section is in direct proportion to the distance from the fiber to the neutral axis. The strain of the FRP and steel rebar satisfies the equation: ɛ FRP= βɛ steel, and the value of β is equal to 1.1-1.3 according to the test results.