Corbacho, J A; Baeza, A
2018-05-17
The evaluation of the radiological impact in soils due to the fly-ash ponds using both in situ techniques and laboratory based measurements is presented. In order to check the in situ techniques capabilities for monitoring this type of industries, a comparison between both techniques was performed. A characterization of external radiation exposure in the fly-ash pond and in its surrounding soils was made. The associated external radiological hazard due to the fly-ash pond has been evaluated. In situ techniques could be used to determine the radiological impact on soils due to fly-ash deposition, but its use could be limited due to the associated uncertainties.
Effects of soil water content on the external exposure of fauna to radioactive isotopes.
Beaugelin-Seiller, K
2016-01-01
Within a recent model intercomparison about radiological risk assessment for contaminated wetlands, the influence of soil saturation conditions on external dose rates was evidenced. This issue joined concerns of assessors regarding the choice of the soil moisture value to input in radiological assessment tools such as the ERICA Tool. Does it really influence the assessment results and how? This question was investigated under IAEA's Modelling and Data for Radiological Impacts Assessments (MODARIA) programme via 42 scenarios for which the soil water content varied from 0 (dry soil) to 100% (saturated soil), in combination with other parameters that may influence the values of the external dose conversion coefficients (DCCs) calculated for terrestrial organisms exposed in soil. A set of α, β, and γ emitters was selected in order to cover the range of possible emission energies. The values of their external DCCs varied generally within a factor 1 to 1.5 with the soil water content, excepted for β emitters that appeared more sensitive (DCCs within a factor of about 3). This may be of importance for some specific cases or for upper tiers of radiological assessments, when refinement is required. But for the general purpose of screening assessment of radiological impact on fauna and flora, current approaches regarding the soil water content are relevant. Copyright © 2015 Elsevier Ltd. All rights reserved.
Cibulsky, Susan M; Sokolowski, Danny; Lafontaine, Marc; Gagnon, Christine; Blain, Peter G.; Russell, David; Kreppel, Helmut; Biederbick, Walter; Shimazu, Takeshi; Kondo, Hisayoshi; Saito, Tomoya; Jourdain, Jean- René; Paquet, Francois; Li, Chunsheng; Akashi, Makoto; Tatsuzaki, Hideo; Prosser, Lesley
2015-01-01
Hazardous chemical, radiological, and nuclear materials threaten public health in scenarios of accidental or intentional release which can lead to external contamination of people. Without intervention, the contamination could cause severe adverse health effects, through systemic absorption by the contaminated casualties as well as spread of contamination to other people, medical equipment, and facilities. Timely decontamination can prevent or interrupt absorption into the body and minimize opportunities for spread of the contamination, thereby mitigating the health impact of the incident. Although the specific physicochemical characteristics of the hazardous material(s) will determine the nature of an incident and its risks, some decontamination and medical challenges and recommended response strategies are common among chemical and radioactive material incidents. Furthermore, the identity of the hazardous material released may not be known early in an incident. Therefore, it may be beneficial to compare the evidence and harmonize approaches between chemical and radioactive contamination incidents. Experts from the Global Health Security Initiative’s Chemical and Radiological/Nuclear Working Groups present here a succinct summary of guiding principles for planning and response based on current best practices, as well as research needs, to address the challenges of managing contaminated casualties in a chemical or radiological/nuclear incident. PMID:26635995
Korir, Geoffrey; Karam, P Andrew
2018-06-11
In the event of a significant radiological release in a major urban area where a large number of people reside, it is inevitable that radiological screening and dose assessment must be conducted. Lives may be saved if an emergency response plan and radiological screening method are established for use in such cases. Thousands to tens of thousands of people might present themselves with some levels of external contamination and/or the potential for internal contamination. Each of these individuals will require varying degrees of radiological screening, and those with a high likelihood of internal and/or external contamination will require radiological assessment to determine the need for medical attention and decontamination. This sort of radiological assessment typically requires skilled health physicists, but there are insufficient numbers of health physicists in any city to perform this function for large populations, especially since many (e.g., those at medical facilities) are likely to be engaged at their designated institutions. The aim of this paper is therefore to develop and describe the technical basis for a novel, scoring-based methodology that can be used by non-health physicists for performing radiological assessment during such radiological events.
Models and parameters for environmental radiological assessments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, C W
1984-01-01
This book presents a unified compilation of models and parameters appropriate for assessing the impact of radioactive discharges to the environment. Models examined include those developed for the prediction of atmospheric and hydrologic transport and deposition, for terrestrial and aquatic food-chain bioaccumulation, and for internal and external dosimetry. Chapters have been entered separately into the data base. (ACR)
[eLearning-radiology.com--sustainability for quality assurance].
Ketelsen, D; Talanow, R; Uder, M; Grunewald, M
2009-04-01
The aim of the study was to analyze the availability of published radiological e-learning tools and to establish a solution for quality assurance. Substantial pubmed research was performed to identify radiological e-learning tools. 181 e-learning programs were selected. As examples two databases expanding their programs with external links, Compare (n = 435 external links) and TNT-Radiology (n = 1078 external links), were evaluated. A concept for quality assurance was developed by an international taskforce. At the time of assessment, 56.4 % (102 / 181) of the investigated e-learning tools were accessible at their original URL. A subgroup analysis of programs published 5 to 8 years ago showed significantly inferior availability to programs published 3 to 5 years ago (p < 0.01). The analysis of external links showed 49.2 % and 61.0 % accessible links for the programs Compare (published 2003) and TNT-Radiology (published 2006), respectively. As a consequence, the domain www.eLearning-radiology.com was developed by the taskforce and published online. This tool allows authors to present their programs and users to evaluate the e-learning tools depending on several criteria in order to remove inoperable links and to obtain information about the complexity and quality of the e-learning tools. More than 50 % of investigated radiological e-learning tools on the Internet were not accessible after a period of 5 to 8 years. As a consequence, an independent, international tool for quality assurance was designed and published online under www.eLearning-radiology.com .
Schreyer, Andreas G; Steinhäuser, René T; Rosenberg, Britta
2018-02-07
Interdisciplinary radiological conferences and boards can improve therapeutic pathways. Because of the reinterpretation and presentation of external image data, which already was read, an additional workload is created which is currently not considered by health care providers. In this review we discuss the ongoing basics and possibilities in health economy for a radiological second opinion for the outpatient and inpatient sector in Germany. Based on up-to-date literature and jurisdiction, we discuss the most important questions for the reimbursement for second opinions and conference presentations of external image data in an FAQ format. Additionally, we focus on the recently introduced E-Health law accordingly. Radiological services considering second opinion or board presentation of externally acquired image data are currently not adequately covered by health care providers. In particular, there is no reimbursement possibility for the inpatient sector. Only patients with private insurance or privately paid second opinions can be charged when these patients visit the radiologist directly. Currently there is no adequate reimbursement possibility for a radiological second opinion or image demonstrations in clinical conferences. It will be essential to integrate adequate reimbursement by health care providers in the near future because of the importance of radiology as an essential diagnostic and therapeutic medical partner. · Currently there is no reimbursement for image interpretation and presentation in boards.. · Second opinions can only be reimbursed for patients with private insurance or privately recompensed.. · The E-Health law allows reimbursement for tele-counsel in very complex situations.. · It will be crucial to integrate radiological second opinion in future reimbursement policies by health care providers.. · Schreyer AG, Steinhäuser RT, Rosenberg B. Externally Acquired Radiological Data for the Clinical Routine - A Review of the Reimbursement Situation in Germany. Fortschr Röntgenstr 2018; DOI: 10.1055/s-0044-101552. © Georg Thieme Verlag KG Stuttgart · New York.
Huet, C; Lemosquet, A; Clairand, I; Rioual, J B; Franck, D; de Carlan, L; Aubineau-Lanièce, I; Bottollier-Depois, J F
2009-01-01
Estimating the dose distribution in a victim's body is a relevant indicator in assessing biological damage from exposure in the event of a radiological accident caused by an external source. This dose distribution can be assessed by physical dosimetric reconstruction methods. Physical dosimetric reconstruction can be achieved using experimental or numerical techniques. This article presents the laboratory-developed SESAME--Simulation of External Source Accident with MEdical images--tool specific to dosimetric reconstruction of radiological accidents through numerical simulations which combine voxel geometry and the radiation-material interaction MCNP(X) Monte Carlo computer code. The experimental validation of the tool using a photon field and its application to a radiological accident in Chile in December 2005 are also described.
Multiple external hazards compound level 3 PSA methods research of nuclear power plant
NASA Astrophysics Data System (ADS)
Wang, Handing; Liang, Xiaoyu; Zhang, Xiaoming; Yang, Jianfeng; Liu, Weidong; Lei, Dina
2017-01-01
2011 Fukushima nuclear power plant severe accident was caused by both earthquake and tsunami, which results in large amount of radioactive nuclides release. That accident has caused the radioactive contamination on the surrounding environment. Although this accident probability is extremely small, once such an accident happens that is likely to release a lot of radioactive materials into the environment, and cause radiation contamination. Therefore, studying accidents consequences is important and essential to improve nuclear power plant design and management. Level 3 PSA methods of nuclear power plant can be used to analyze radiological consequences, and quantify risk to the public health effects around nuclear power plants. Based on multiple external hazards compound level 3 PSA methods studies of nuclear power plant, and the description of the multiple external hazards compound level 3 PSA technology roadmap and important technical elements, as well as taking a coastal nuclear power plant as the reference site, we analyzed the impact of off-site consequences of nuclear power plant severe accidents caused by multiple external hazards. At last we discussed the impact of off-site consequences probabilistic risk studies and its applications under multiple external hazards compound conditions, and explained feasibility and reasonableness of emergency plans implementation.
NASA Astrophysics Data System (ADS)
Abdullahi, S.; Ismail, A. F.; Samat, S. B.; Yasir, M. S.
2018-04-01
The activity concentration and radiological risk of commonly used flooring materials (tiles) in Malaysia were studied. The natural radionuclide concentrations of 226Ra, 232Th and 40K were measured using high-purity germanium detector. The average concentration of 226Ra, 232Th and 40K in the samples were 65.75±1.1 Bq kg-1, 61.92±1.43 Bq kg-1 and 617.77±6.72 Bq kg-1 respectively. The mean concentration of radium equivalent activity, absorbed dose rate, external and internal hazard indices and annual effective dose equivalent were 195.21±2.88 Bq kg-1, 92.75±1.27 nGy h-1, 0.53±0.01, 0.7±0.01 and 0.44±0.0 mSv y-1 respectively. The aim was to assess the possible radiological risks attributed from the tile materials. Even though, the activity concentrations were higher than worldwide average values, but none of the radiological impact parameters exceeded the maximum recommended values. Hence, it was concluded that, contribution of tiles to radiation exposure is negligible and therefore, radiologically safe to use as building materials.
RADIOLOGICAL IMPACTS ASSESSMENT FOR WORKERS IN CERAMIC INDUSTRY IN SERBIA.
Todorovic, Nataša; Mrda, Dušan; Hansman, Jan; Todorovic, Slavko; Nikolov, Jovana; Krmar, Miodrag
2017-11-01
Studies have been carried out to determine the natural radioactivity in some materials used in ceramic industry (zircon, zirkosil, Zircobit MO/S, zircon silicate, zirklonil frit, hematite, bentonite, wollastonite, raw kaolin, kaolinized granite, sileks ball, feldspar, pigment, white base serigraphic, engobe) and their associated radiation hazard. The external hazard index, Hex, values, radium equivalent activity, Raeq, total absorbed dose rates, D and annual effective dose, De were derived for all measured materials and compared with the recommended values to assess the external radiation hazards to workers who worked in ceramic industries in Serbia. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
External ophthalmoplegia with orbital myositis in an adult patient after chickenpox infection.
Kim, Jung-Hoon; Lee, Seung-Jun; Kim, Moosang
2014-05-16
Herpes zoster and chickenpox are caused by a single virus, varicella-zoster virus. Herpes zoster ophthalmicus-associated ophthalmoplegia is well documented. Very rarely, herpes zoster and chickenpox cause external ophthalmoplegia. A 48-year-old man was diagnosed with chickenpox and treated with intravenous acyclovir. He suddenly reported diplopia and restricted left eye movement. MRI of the orbit revealed thickening and abnormal contrast enhancement of the preseptal space and lateral rectus muscle of the left eye. In this case, external ophthalmoplegia occurred following chickenpox with radiological evidence of orbital myositis. To the best of our knowledge, this is the first case report of external ophthalmoplegia of radiologically confirmed orbital myositis after chickenpox infection. 2014 BMJ Publishing Group Ltd.
Basford, Tavis J; Poenaru, Dan; Silva, Mariana
2003-05-01
Pediatric central venous catheters (CVCs) traditionally have been placed surgically, guided by anatomic landmarks. Increasingly, interventional radiology services are inserting CVCs using ultrasound image guidance. This study compares the frequency of delayed complications in CVCs placed surgically or radiologically in a pediatric oncology population. Data on CVCs placed in one academic institution over 10 years were collected and analyzed retrospectively. Main outcomes assessed were infectious complications, mechanical complications, and premature catheter removal. Ninety-eight CVCs-comprising 52 external tunneled catheters (ETCs) and 46 subcutaneous ports-were assessed in 67 patients. Median patient age was 6.1 years for children with external catheters and 7.8 years for those with ports. Both infectious and mechanical complications were significantly more common among surgically placed ETCs than those placed radiologically (P <.05). Complications per 1,000 catheter days and premature removal showed a trend toward greater frequency among surgical ETCs, although this did not reach statistical significance. No consistent trends were seen in complications among ports. Pediatric patients with CVCs, especially those with external catheters, experience frequent delayed complications. Patients with radiologically inserted ETCs may encounter fewer complications than those with surgically placed ones. This corroborates previous reports in the literature suggesting image-guided CVC placement as a preferable alternative to traditional techniques. Copyright 2003 Elsevier Inc. All rights reserved.
Review of Dangerous Radioisotopes: What is Available in Practice, What Should We be Concerned About?
2015-06-01
of the credibility of a radioactive material as a radiological weapon to be applied to specific scenarios. • This does not replace the IAEA "AID...34 ratios, but more precisely applies this concept to assessments of interest. 7Jt#,$ 2 IDA I Radiological Weapons • This analysis identified the...radiological weapons under seven different routes of exposure (or types of radiological weapons ), including external irradiation from a point source
NASA Astrophysics Data System (ADS)
Courageot, Estelle; Sayah, Rima; Huet, Christelle
2010-05-01
Estimating the dose distribution in a victim's body is a relevant indicator in assessing biological damage from exposure in the event of a radiological accident caused by an external source. When the dose distribution is evaluated with a numerical anthropomorphic model, the posture and morphology of the victim have to be reproduced as realistically as possible. Several years ago, IRSN developed a specific software application, called the simulation of external source accident with medical images (SESAME), for the dosimetric reconstruction of radiological accidents by numerical simulation. This tool combines voxel geometry and the MCNP(X) Monte Carlo computer code for radiation-material interaction. This note presents a new functionality in this software that enables the modelling of a victim's posture and morphology based on non-uniform rational B-spline (NURBS) surfaces. The procedure for constructing the modified voxel phantoms is described, along with a numerical validation of this new functionality using a voxel phantom of the RANDO tissue-equivalent physical model.
Courageot, Estelle; Sayah, Rima; Huet, Christelle
2010-05-07
Estimating the dose distribution in a victim's body is a relevant indicator in assessing biological damage from exposure in the event of a radiological accident caused by an external source. When the dose distribution is evaluated with a numerical anthropomorphic model, the posture and morphology of the victim have to be reproduced as realistically as possible. Several years ago, IRSN developed a specific software application, called the simulation of external source accident with medical images (SESAME), for the dosimetric reconstruction of radiological accidents by numerical simulation. This tool combines voxel geometry and the MCNP(X) Monte Carlo computer code for radiation-material interaction. This note presents a new functionality in this software that enables the modelling of a victim's posture and morphology based on non-uniform rational B-spline (NURBS) surfaces. The procedure for constructing the modified voxel phantoms is described, along with a numerical validation of this new functionality using a voxel phantom of the RANDO tissue-equivalent physical model.
Ebaid, Y Y; Bakr, W F
2012-09-01
The aim of this study was to comprehensively study the radiological hazards of granite and marble used as a building material in Egypt. The activity concentrations of (226)Ra, (232)Th and (40)K were determined using high-resolution hyper-pure germanium detectors in 25 samples of different types of commercially available granite and marble. The measured activity concentrations for these natural radionuclides were compared with the reported data for Egypt and other countries. In order to assess the radiological impact, the radiation hazard parameters such as radium equivalent activity (Ra(eq)) and hazard level index (I(γ)) were calculated. The internal and external dose rates due to natural radionuclides in granite and marble were also calculated. The data obtained were considered as helpful in regulating the use of building materials in Egypt.
Radioactivity concentrations in soils in the Qingdao area, China.
Qu, Limei; Yao, De; Cong, Pifu; Xia, Ning
2008-10-01
The specific activity concentrations of radionuclides (238)U, (232)Th, and (40)K of 2300 sampling points in the Qingdao area were measured by an FD-3022 gamma-ray spectrometer. The radioactivity concentrations of (238)U, (232)Th, and (40)K ranged from 3.3 to 185.3, from 6.9 to 157.2, and from 115.8 to 7834.4 Bq kg(-1), respectively. The air-absorbed dose at 1 meter above ground, effective annual dose, external hazard index, and radium equivalent activity were also calculated to systematically evaluate the radiological hazards of the natural radioactivity in Qingdao. The air-absorbed dose, effective annual dose, external hazard index, and radium equivalent activity in the study area were 98.6 nGy h(-1), 0.12 mSv, 0.56, 197 Bq kg(-1), respectively. Compared with the worldwide value, the air-absorbed dose is slightly high, but the other factors are all lower than the recommended value. The natural external exposure will not pose significant radiological threat to the population. In conclusion, the Qingdao area is safe with regard to the radiological level and suitable for living.
Radiological assessment. A textbook on environmental dose analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Till, J.E.; Meyer, H.R.
1983-09-01
Radiological assessment is the quantitative process of estimating the consequences to humans resulting from the release of radionuclides to the biosphere. It is a multidisciplinary subject requiring the expertise of a number of individuals in order to predict source terms, describe environmental transport, calculate internal and external dose, and extrapolate dose to health effects. Up to this time there has been available no comprehensive book describing, on a uniform and comprehensive level, the techniques and models used in radiological assessment. Radiological Assessment is based on material presented at the 1980 Health Physics Society Summer School held in Seattle, Washington. Themore » material has been expanded and edited to make it comprehensive in scope and useful as a text. Topics covered include (1) source terms for nuclear facilities and Medical and Industrial sites; (2) transport of radionuclides in the atmosphere; (3) transport of radionuclides in surface waters; (4) transport of radionuclides in groundwater; (5) terrestrial and aquatic food chain pathways; (6) reference man; a system for internal dose calculations; (7) internal dosimetry; (8) external dosimetry; (9) models for special-case radionuclides; (10) calculation of health effects in irradiated populations; (11) evaluation of uncertainties in environmental radiological assessment models; (12) regulatory standards for environmental releases of radionuclides; (13) development of computer codes for radiological assessment; and (14) assessment of accidental releases of radionuclides.« less
Chaudhry, Naueen A; Zahid, Kamran; Keihanian, Sara; Dai, Yunfeng; Zhang, Qing
2017-11-28
To investigate the behavior of pulsatile pressure zones (PPZ's) as noted on high resolution esophageal impedance manometry (HREIM), and determine their association with dysphagia. Retrospective, single center case control design screening HREIM studies for cases (dysphagia) and controls (no dysphagia). Thoracic radiology studies were reviewed further in cases for (thoracic cardiovascular) thoracic cardiovascular (TCV) structures in esophageal proximity to compare with HREIM findings. Manometric data was collected for number, location, axial length, PPZ pressure and esophageal clearance function (impedance). Among 317 screened patients, 56% cases and 64% controls had PPZ's. Fifty cases had an available thoracic radiology comparison. The distribution of PPZ's in these 50 cases and 59 controls was similar (average 1.4 PPZ/patient). Controls (mean 31.2 ± SD 12 years) were a significantly younger population than cases (mean 67.3 ± SD 14.9 years) with P < 0.0001. The upright posture PPZ pressure was higher in controls (15.7 ± 10.0 mmHg) than cases (10.8 ± 9.7 mmHg). Although statistically significant ( P = 0.005), it was a weak predictor using logistic regression and ROC model (AUC = 0.65). Three dysphagia patients had partial compression from external TCV on radiology (1 aberrant subclavian artery, 2 dilated left atrium). The posture (supine vs upright) with more prominent PPZ's impaired bolus clearance in 9 additional cases by > 20%. Transmitted TCV pulsations observed in HREIM bear no significant impact on swallowing. However, in older adults with dysphagia, evidence of impaired bolus clearance on impedance should be evaluated for external TCV compression. These associations have never been explored previously in literature, and are novel.
Prognostic factors in prostate cancer patients treated by radical external beam radiotherapy.
Garibaldi, Elisabetta; Gabriele, Domenico; Maggio, Angelo; Delmastro, Elena; Garibaldi, Monica; Russo, Filippo; Bresciani, Sara; Stasi, Michele; Gabriele, Pietro
2017-09-01
The aim of this paper was to analyze, retrospectively, in prostate cancer patients treated in our Centre with external beam radiotherapy, the prognostic factors and their impact on the outcome in terms of cancer-specific survival (CSS), biochemical disease-free survival (BDFS) and clinical disease-free survival (CDFS). From October 1999 and March 2012, 1080 patients were treated with radiotherapy at our Institution: 87% of them were classified as ≤cT2, 83% had a Gleason Score (GS) ≤7, their mean of iPSA was 18 ng/mL, and the rate of clinical positive nodes was 1%. The mean follow-up was 81 months. The statistically significant prognostic factors for all groups of patients at both, univariate and multivariate analysis, were the GS and the iPSA. In intermediate- and high- or very-high-risk patients at multivariate analysis other prognostic factors for CSS were positive nodes on computed tomography (CT) scan and rectal preparation during the treatment; for BDFS, the prognostic factors were patient risk classification, positive lymph nodes on CT scan and rectal/bladder preparation; for CDFS, the prognostic factors were the number of positive core on biopsy (P=0.003), positive lymph nodes on CT scan, and radiotherapy (RT) dose. In high/very-high risk patient group at multivariate analysis other prognostic factors for CSS were clinical/radiological stage and RT dose, for BDFS they were adjuvant hormone therapy, clinical/radiological stage, and RT dose >77.7 Gy, and for CDFS they were clinical/radiological stage and RT dose >77.7 Gy. The results of this study confirm the prognostic factors described in the recent literature, with the addition of rectal/bladder preparation, generally known for its effect on toxicity but not yet on outcome.
Chaudhry, Naueen A; Zahid, Kamran; Keihanian, Sara; Dai, Yunfeng; Zhang, Qing
2017-01-01
AIM To investigate the behavior of pulsatile pressure zones (PPZ’s) as noted on high resolution esophageal impedance manometry (HREIM), and determine their association with dysphagia. METHODS Retrospective, single center case control design screening HREIM studies for cases (dysphagia) and controls (no dysphagia). Thoracic radiology studies were reviewed further in cases for (thoracic cardiovascular) thoracic cardiovascular (TCV) structures in esophageal proximity to compare with HREIM findings. Manometric data was collected for number, location, axial length, PPZ pressure and esophageal clearance function (impedance). RESULTS Among 317 screened patients, 56% cases and 64% controls had PPZ’s. Fifty cases had an available thoracic radiology comparison. The distribution of PPZ’s in these 50 cases and 59 controls was similar (average 1.4 PPZ/patient). Controls (mean 31.2 ± SD 12 years) were a significantly younger population than cases (mean 67.3 ± SD 14.9 years) with P < 0.0001. The upright posture PPZ pressure was higher in controls (15.7 ± 10.0 mmHg) than cases (10.8 ± 9.7 mmHg). Although statistically significant (P = 0.005), it was a weak predictor using logistic regression and ROC model (AUC = 0.65). Three dysphagia patients had partial compression from external TCV on radiology (1 aberrant subclavian artery, 2 dilated left atrium). The posture (supine vs upright) with more prominent PPZ’s impaired bolus clearance in 9 additional cases by > 20%. CONCLUSION Transmitted TCV pulsations observed in HREIM bear no significant impact on swallowing. However, in older adults with dysphagia, evidence of impaired bolus clearance on impedance should be evaluated for external TCV compression. These associations have never been explored previously in literature, and are novel. PMID:29209125
Radiological evaluation of ankle arthrodesis with Ilizarov fixation compared to internal fixation.
Morasiewicz, Piotr; Dejnek, Maciej; Urbański, Wiktor; Dragan, Szymon Łukasz; Kulej, Mirosław; Dragan, Szymon Feliks
2017-07-01
We asked whether the type of ankle joint arthrodesis stabilization will affect: (1) rate of union, (2) rate of adjacted-joint arthritis, (3) malalignment of the ankle joint. We retrospectively radiological studied 62 patients who underwent ankle arthrodesis with Ilizarov external fixator stabilization (group 1,n=29) or internal stabilization (group 2,n=33) from 2006 to 2015. Radiologic outcomes were mesure by: (1) rate of union, (2) rate of adjacent-joint arthritis, (3) malalignment of the ankle joint. The Levene's test,Mann-Whitney U test and Students t-test were used to the statistical analyses. Ankle fusion was achieved in 100% of patients treated with external fixation and in 88% with internal stabilization. Desired frontal plane alignment was achieved in 100% of patients with external fixation and 76% with internal stabilization. Desired sagittal plane alignment was achieved in 100% of external fixation and 85% of internal stabilization. A total of 14 (48.3%) patients from group 1 showed a radiographic evidence of pre-existing adjacent-joint OA. The radiographic evidence of pre-existing adjacent-joint OA was also found in 27(81.8%) subjects from group 2. Alterations of adjacent joints were also found on postoperative radiograms of 19 (65.5%) patients subjected to Ilizarov fixation and in all 33 patients from group 2. Ilizarov fixation of ankle arthrodesis is associated with lower prevalence of adjacent-joint OA and ankle joint misalignment,and with higher fusion rates than after internal fixation.Although achieving a complex ankle fusion is generally challenging,radiological outcomes after fixation with the Ilizarov apparatus are better than after internal stabilization. Copyright © 2017 Elsevier Ltd. All rights reserved.
The radiological impact of electricity generation by U.K. coal and nuclear systems.
Robson, A
1984-05-01
Radiological impact is discussed for U.K. coal and nuclear power cycles under normal operation. The type having the greater impact depends on the radiological basis of the comparison, the particular nuclear reactor system considered and whether or not the whole fuel cycle, especially irradiated nuclear fule reprocessing , is included in the analysis. More importantly, the various impacts are shown to be generally acceptable in an absolute sense i.e. exposures are less than and usually low in comparison with radiological safety guidelines and everyday natural radiation exposures.
Hawkins, C Matthew; Bowen, Michael A; Gilliland, Charles A; Walls, D Gail; Duszak, Richard
2015-09-01
The numbers of nurse practitioners (NPs) and physician assistants (PAs) are increasing throughout the entire health care enterprise, and a similar expansion continues within radiology. The use of radiologist assistants is growing in some radiology practices as well. The increased volume of services rendered by this growing nonphysician provider subset of the health care workforce within and outside radiology departments warrants closer review, particularly with regard to their potential influence on radiology education and medical imaging resource utilization. In this article (the second in a two-part series), the authors review recent literature and offer recommendations for radiology practices regarding the impact NPs, PAs, and radiologist assistants may have on interventional and diagnostic radiology practices. Their potential impact on medical education is also discussed. Finally, staffing for radiology departments, as a result of an enlarging nonradiology NP and PA workforce ordering diagnostic imaging, is considered. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Radiological impact assessment to the environment due to waste from disposal of porcelain.
Morsi, Tarek; Hegazy, Rehab; Badawy, Wael
2017-06-01
The present study aimed to assess the radiological parameters from gamma rays due to the uncontrolled disposal of porcelain waste to the environment. Qualitative and quantitative identification of radionuclides in the investigated samples was carried out by means of a high-purity germanium (HPGe) detector. The average activity concentrations of the local porcelain samples were measured as 208.28 Bq/kg for 226 Ra, 125.73 Bq/kg for 238 U, 84.94 Bq/kg for 232 Th and 1033.61 Bq/kg for 40 K, respectively. The imported samples had an average activity of 240.57 Bq/kg for 226 Ra, 135.56 Bq/kg for 238 U, 115.74 Bq/kg for 232 Th and 1312.49 Bq/kg for 40 K, respectively. Radiological parameters and the radium equivalent Ra eq for the investigated samples were calculated. The external and internal hazard indices, representative level index (I γ ), alpha index (I α ), and the exemption level (I x ), were estimated to be higher than the recommended value (unity), while the average activity concentrations for the studied samples were higher than recommended levels. In conclusion, we are concerned that disposal of porcelain in the environment might be a significant hazard.
Chauhan, Narvir Singh; Sharma, Yash Paul; Bhagra, Tilak; Sud, Bindu
2012-01-01
Anomalies of third or fourth branchial apparatus origin are very uncommon and present as recurrent neck infections or thyroiditis with a predominant left-sided involvement. Radiological diagnosis requires a high index of suspicion and is critical for initiation of proper treatment. We describe a case of branchial sinus of pyriform fossa with external fistulization that presented in adulthood and was diagnosed on computed tomographic scan. The radiological features of this rare anomaly are revisited. Copyright © 2012 Elsevier Inc. All rights reserved.
Hanford Radiological Protection Support Services Annual Report for 1998
DOE Office of Scientific and Technical Information (OSTI.GOV)
DE Bihl; JA MacLellan; ML Johnson
1999-05-14
During calendar year (CY) 1998, the Pacific Northwest National Laboratory (PNNL) performed its customary radiological protection support services in support of the U.S. Department of Energy (DOE) Richland Operations OffIce (RL) and the Hanford contractors. These services included: 1) external dosimetry, 2) internal dosimetry, 3) in vivo measurements, 4) radiological records, 5) instrument calibra- tion and evaluation, and 6) calibration of radiation sources traceable to the National Institute of Standards and Technology (MST). The services were provided under a number of projects as summarized here.
Grimm, Lars J; Lowell, Dorothy A; Cater, Sarah W; Yoon, Sora C
2017-10-01
The purpose of this study is to determine how the motivations to pursue a career in radiology differ by gender. In addition, the influence of medical school radiology education will be assessed. Radiology applicants to our institution from the 2015-2016 interview season were offered an online survey in February 2016. Respondents scored the influence of 24 aspects of radiology on their decision to pursue radiology. Comparisons were made between male and female respondents. Respondents were also asked the type of medical school radiology education they received and to score the influence this experience had on their decision to pursue radiology. There were 202 total respondents (202/657) including 47 women and 155 men. Compared to men, the following factors had a more negative impact on women: flexible work hours (P = 0.04), work environment (P = 0.04), lifestyle (P = 0.04), impact on patient care (P = 0.05), high current debt load (P = 0.02), gender distribution of the field (P = 0.04), and use of emerging/advanced technology (P = 0.02). In contrast, women felt more favorably about the opportunities for leadership (P = 0.04) and research (P < 0.01). Dedicated radiology exposure was as follows: 20% (n = 20) none, 48% (n = 96) preclinical exposure, 55% (n = 111) elective rotation, and 18% (n = 37) core rotation. More intensive radiology exposure via a core rotation had a significantly positive impact on the decision to pursue radiology (P < 0.01). Male and female radiology applicants are motivated by different aspects of radiology, which may influence residency recruitment practices. In addition, more intensive radiology exposure has a net positive impact on the decision to pursue radiology. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Casualty Estimation for Nuclear and Radiological Weapons
2016-06-01
usually defined as energy deposited (joule) per unit of mass (kilogram). See gray and rad. Acute Radiation Syndrome (ARS): ARS is a serious illness...I-2 ARS Acute Radiation Syndrome BSA body surface area CBRN chemical, biological, radiological, and nuclear CONV convalescent CUT cutaneous DOW...include acute effects, which may result from internal or external radiation exposure. The severity of these effects is directly related to the dosage
Becker, Murray; Goldszal, Alberto; Detal, Julie; Gronlund-Jacob, Judith; Epstein, Robert
2015-06-01
The aim of this study was to assess whether the complex radiology IT infrastructures needed for large, geographically diversified, radiology practices are inherently stable with respect to system downtimes, and to characterize the nature of the downtimes to better understand their impact on radiology department workflow. All radiology IT unplanned downtimes over a 12-month period in a hybrid academic-private practice that performs all interpretations in-house (no commercial "nighthawk" services) for approximately 900,000 studies per year, originating at 6 hospitals, 10 outpatient imaging centers, and multiple low-volume off-hours sites, were logged and characterized using 5 downtime metrics: duration, etiology, failure type, extent, and severity. In 12 consecutive months, 117 unplanned downtimes occurred with the following characteristics: duration: median time = 3.5 hours with 34% <1.5 hours and 30% >12 hours; etiology: 87% were due to software malfunctions, and 13% to hardware malfunctions; failure type: 88% were transient component failures, 12% were complete component failures; extent: all sites experienced downtimes, but downtimes were always localized to a subset of sites, and no system-wide downtimes occurred; severity (impact on radiologist workflow): 47% had minimal impact, 50% moderate impact, and 3% severe impact. In the complex radiology IT system that was studied, downtimes were common; they were usually a result of transient software malfunctions; the geographic extent was always localized rather than system wide; and most often, the impacts on radiologist workflow were modest. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Machine Learning in Radiology: Applications Beyond Image Interpretation.
Lakhani, Paras; Prater, Adam B; Hutson, R Kent; Andriole, Kathy P; Dreyer, Keith J; Morey, Jose; Prevedello, Luciano M; Clark, Toshi J; Geis, J Raymond; Itri, Jason N; Hawkins, C Matthew
2018-02-01
Much attention has been given to machine learning and its perceived impact in radiology, particularly in light of recent success with image classification in international competitions. However, machine learning is likely to impact radiology outside of image interpretation long before a fully functional "machine radiologist" is implemented in practice. Here, we describe an overview of machine learning, its application to radiology and other domains, and many cases of use that do not involve image interpretation. We hope that better understanding of these potential applications will help radiology practices prepare for the future and realize performance improvement and efficiency gains. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Valenti, Philippe; Maqdes, Ali; Werthel, Jean-David
2017-10-01
The purpose of this study was to report clinical and radiological results of reverse shoulder arthroplasty (RSA) after failure of either a deltoid and/or a latissimus dorsi transfer. Between 2001 and 2011, ten patients (average age, 61 years) underwent primary RSA after a failed tendon transfer for irreparable postero-superior rotator cuff tear (five deltoid muscle transfers, four latissimus dorsi transfers and one both). Average follow-up was 48 months. Outcome measures included pain, range of motion and postoperative Constant-Murley score. Pain score improved significantly from a mean 8.3 to a mean 0.3. Mean shoulder elevation improved from 66 to 134°, and absolute Constant-Murley scores increased from 25.8 to 62.8 The mean improvement in external rotation was limited to 7.5°. Subjectively, six patients rated the result as much better and three rated it as better than before surgery. Failure of the tendon transfer with deterioration of the functional outcomes can be salvaged with a RSA with no impact on the expected outcome.
Relativity Screens for Misvalued Medical Services: Impact on Noninvasive Diagnostic Radiology.
Rosenkrantz, Andrew B; Silva, Ezequiel; Hawkins, C Matthew
2017-11-01
In 2006, the AMA/Specialty Society Relative Value Scale Update Committee (RUC) introduced ongoing relativity screens to identify potentially misvalued medical services for payment adjustments. We assess the impact of these screens upon the valuation of noninvasive diagnostic radiology services. Data regarding relativity screens and relative value unit (RVU) changes were obtained from the 2016 AMA Relativity Assessment Status Report. All global codes in the 2016 Medicare Physician Fee Schedule with associated work RVUs were classified as noninvasive diagnostic radiology services versus remaining services. The frequency of having ever undergone a screen was compared between the two groups. Screened radiology codes were further evaluated regarding the RVU impact of subsequent revaluation. Of noninvasive diagnostic radiology codes, 46.0% (201 of 437) were screened versus 22.2% (1,460 of 6,575) of remaining codes (P < .001). Most common screens for which radiology codes were identified as potentially misvalued were (1) high expenditures (27.5%) and (2) high utilization (25.6%). The modality and body region most likely to be identified in a screen were CT (82.1%) and breast (90.9%), respectively. Among screened radiology codes, work RVUs, practice expense RVUs, and nonfacility total RVUs decreased in 20.3%, 65.9%, and 75.3%, respectively. All screened CT, MRI, brain, and spine codes exhibited decreased total RVUs. Policymakers' ongoing search for potentially misvalued medical services has disproportionately impacted noninvasive diagnostic radiology services, risking the introduction of unintended or artificial shifts in physician practice. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilchrist, R.L.; Parker, G.B.; Mishima, J.
1978-03-01
The potential radiological and toxicological hazard of depleted uranium aerosol release was investigated. This type of release might arise from accidents with XM-774 ammunition involving great heat. Twelve rounds of packaged ammunition were subjected to an external heat (burn) test. Examination of the site on the day following the test revealed that all 12 depleted uranium penetrators were completely intact. Oxidation of the penetrators was not apparent, even on the most severely burned projectile located at ground zero. Eleven of the 12 projectiles were recovered with the sabots intact; some sabots appeared charred. It was concluded that no airborne releasemore » of depleted uranium had occurred and subsequently there had been no radiological or toxicological hazard from DU during this test. However, this conclusion may not apply to the release of depleted uranium in other types of fires involving this ammunition because other factors may affect the fire. These factors include type of fuel, number of ammunition rounds, and type of structure housing the ammunition.« less
Study of natural radioactivity in Mansehra granite, Pakistan: environmental concerns.
Qureshi, Aziz Ahmed; Jadoon, Ishtiaq Ahmed Khan; Wajid, Ali Abbas; Attique, Ahsan; Masood, Adil; Anees, Muhammad; Manzoor, Shahid; Waheed, Abdul; Tubassam, Aneela
2014-03-01
A part of Mansehra Granite was selected for the assessment of radiological hazards. The average activity concentrations of (226)Ra, (232)Th and (40)K were found to be 27.32, 50.07 and 953.10 Bq kg(-1), respectively. These values are in the median range when compared with the granites around the world. Radiological hazard indices and annual effective doses were estimated. All of these indices were found to be within the criterion limits except outdoor external dose (82.38 nGy h(-1)) and indoor external dose (156.04 nGy h(-1)), which are higher than the world's average background levels of 51 and 55 nGy h(-1), respectively. These values correspond to an average annual effective dose of 0.867 mSv y(-1), which is less than the criterion limit of 1 mSv y(-1) (ICRP-103). Some localities in the Mansehra city have annual effective dose higher than the limit of 1 mSv y(-1). Overall, the Mansehra Granite does not pose any significant radiological health hazard in the outdoor or indoor.
Radiology journals in transition: a summary of the 2013 Intersociety Committee Summer Conference.
Dodd, Gerald D
2015-01-01
The digital and online revolution is having a profound impact on radiology journals, forcing a migration from print to online publication and altering traditional revenue streams needed to sustain the journals. The 2013 Intersociety Committee Summer Conference attendees reviewed the history of the development of radiology journals, explored the forces driving the transition from print to electronic publication, and examined the impact of the alteration of the traditional revenue streams, such as subscription and advertisement dollars, on the financial sustainability of journals. The attendees also discussed the international movement toward open access to journal content and its impact on a journal's financial viability. Lastly, the committee explored the perceived value of radiology journals based on readership type: academic, private practice, or industry. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
INDUSTRIAL/MILITARY ACTIVITY-INITIATED ACCIDENT SCREENING ANALYSIS
DOE Office of Scientific and Technical Information (OSTI.GOV)
D.A. Kalinich
1999-09-27
Impacts due to nearby installations and operations were determined in the Preliminary MGDS Hazards Analysis (CRWMS M&O 1996) to be potentially applicable to the proposed repository at Yucca Mountain. This determination was conservatively based on limited knowledge of the potential activities ongoing on or off the Nevada Test Site (NTS). It is intended that the Industrial/Military Activity-Initiated Accident Screening Analysis provided herein will meet the requirements of the ''Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants'' (NRC 1987) in establishing whether this external event can be screened from further consideration or must be includedmore » as a design basis event (DBE) in the development of accident scenarios for the Monitored Geologic Repository (MGR). This analysis only considers issues related to preclosure radiological safety. Issues important to waste isolation as related to impact from nearby installations will be covered in the MGR performance assessment.« less
Buck, Ursula; Naether, Silvio; Braun, Marcel; Bolliger, Stephan; Friederich, Hans; Jackowski, Christian; Aghayev, Emin; Christe, Andreas; Vock, Peter; Dirnhofer, Richard; Thali, Michael J
2007-07-20
The examination of traffic accidents is daily routine in forensic medicine. An important question in the analysis of the victims of traffic accidents, for example in collisions between motor vehicles and pedestrians or cyclists, is the situation of the impact. Apart from forensic medical examinations (external examination and autopsy), three-dimensional technologies and methods are gaining importance in forensic investigations. Besides the post-mortem multi-slice computed tomography (MSCT) and magnetic resonance imaging (MRI) for the documentation and analysis of internal findings, highly precise 3D surface scanning is employed for the documentation of the external body findings and of injury-inflicting instruments. The correlation of injuries of the body to the injury-inflicting object and the accident mechanism are of great importance. The applied methods include documentation of the external and internal body and the involved vehicles and inflicting tools as well as the analysis of the acquired data. The body surface and the accident vehicles with their damages were digitized by 3D surface scanning. For the internal findings of the body, post-mortem MSCT and MRI were used. The analysis included the processing of the obtained data to 3D models, determination of the driving direction of the vehicle, correlation of injuries to the vehicle damages, geometric determination of the impact situation and evaluation of further findings of the accident. In the following article, the benefits of the 3D documentation and computer-assisted, drawn-to-scale 3D comparisons of the relevant injuries with the damages to the vehicle in the analysis of the course of accidents, especially with regard to the impact situation, are shown on two examined cases.
Ma, Chuang; Deng, Qiang; Pu, Hongwei; Cheng, Xinchun; Kan, Yuhua; Yang, Jing; Yusufu, Aihemaitijiang; Cao, Li
2016-01-01
The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after 1 week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P=0.001), supination, (P=0.047) and extension (P=0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at 1 year. The plating group had a greater occurrence of wound infection (P=0.043), tendonitis, (P=0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the “gross motor” category (walking upstairs, bending over, walking 500 yards; P=0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after 1 year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries. PMID:27408765
NASA Astrophysics Data System (ADS)
Abed Gatea, Mezher; Ahmed, Anwar A.; jundee kadhum, Saad; Ali, Hasan Mohammed; Hussein Muheisn, Abbas
2018-05-01
The Safety Assessment Framework (SAFRAN) software has implemented here for radiological safety analysis; to verify that the dose acceptance criteria and safety goals are met with a high degree of confidence for dismantling of Tammuz-2 reactor core at Al-tuwaitha nuclear site. The activities characterizing, dismantling and packaging were practiced to manage the generated radioactive waste. Dose to the worker was considered an endpoint-scenario while dose to the public has neglected due to that Tammuz-2 facility is located in a restricted zone and 30m berm surrounded Al-tuwaitha site. Safety assessment for dismantling worker endpoint-scenario based on maximum external dose at component position level in the reactor pool and internal dose via airborne activity while, for characterizing and packaging worker endpoints scenarios have been done via external dose only because no evidence for airborne radioactivity hazards outside the reactor pool. The in-situ measurements approved that reactor core components are radiologically activated by Co-60 radioisotope. SAFRAN results showed that the maximum received dose for workers are (1.85, 0.64 and 1.3mSv/y) for activities dismantling, characterizing and packaging of reactor core components respectively. Hence, the radiological hazards remain below the low level hazard and within the acceptable annual dose for workers in radiation field
Hoffmann, Jason C; Singh, Ayushi; Mittal, Sameer; Peterkin, Yuri; Flug, Jonathan
2016-01-01
Over the past 10 years, there has been increased attending-level image interpretation during what has typically been considered the on-call period. The purpose of this study is to survey radiology attending physicians and assess their perceptions about how the presence of radiology attending physicians during the on-call period affects patient care and resident education. Two hundred eighty-eight radiology attendings completed the online survey. 70% believe that after hours final reads by radiology attendings improves patient care. 56% believe that this additional attending presence has a negative impact on the ability of graduating residents to efficiently interpret studies independently. A majority of radiology attending physicians in this study believe that increased in-house radiology attending coverage is harming resident training across the United States, yet also believe this attending presence is important for patient care. Additional studies are needed to quantify and further evaluate this effect, and develop strategies to address potential negative impacts on radiology resident education. Copyright © 2016 Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-10
.... Approximately 1,050 acres (425 hectares) are used for agriculture, and the remaining land is a mixture of woods... radiological impacts in the environment that may result from the proposed EPU. Non-Radiological Impacts Land Use and Aesthetic Impacts Potential land use and aesthetic impacts from the proposed EPU include...
Rosenkrantz, Andrew B; Ayoola, Abimbola
2016-06-01
The aim of this study was to evaluate the trends in the impact factor (IF) of radiological journals over a recent 12-year period, including associations between IF and journal topic. Journal Citation Reports (JCR) was used to identify all biomedical journals and all radiological journals (assigned a JCR category of "Radiology, Nuclear Medicine, & Medical Imaging"), along with journal IF, in 2003 and 2014. Radiological journals were manually classified by topic. Trends in median IF (mIF) were assessed. The number of radiological journals increased from 83 (2003) to 125 (2014) (all biomedical journals: 5907 to 8718, respectively). mIF of radiological journals increased from 1.42 (2003) to 1.75 (2014) (all biomedical journals: 0.93 to 1.46, respectively). The most common topic among new radiological journals was general (nonspecialized) radiology (8). Five new radiological journals in 2014 were in topics (cancer imaging and molecular imaging) having no journals in 2003. mIF of general radiological journals was 1.49. Topics having highest mIF were cardiac imaging (2.94), optics (2.86), molecular imaging (2.77), radiation oncology (2.60), and neuroradiology (2.25). Topics with lowest mIF were ultrasound (1.19) and interventional radiology (1.44). Topics with the largest increase in mIF were cardiac imaging (from 1.17 to 2.94) and neuroradiology (from 1.07 to 2.25). Radiological journals exhibited higher mIF than biomedical journals overall. Among radiological journals, subspecialty journals had highest mIF. While a considerable number of new radiological journals since 2003 were general radiology journals having relatively low IF, there were also new journal topics representing emerging areas of subspecialized radiological research. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Fadol, Nooreldin; Idriss, Hajo; Salih, Isam; Ragab, Nserdin A; Osman, Safa; Sam, Adam K
2018-06-01
This study was conducted to assess the level of radioactivity and the radiation hazards associated with granite rocks used for construction of buildings. The measurement of radioactivity content of the rock samples was performed with gamma-spectrometry equipped with Nal (TI) detector. From the results obtained in this study the average activity concentrations of 226Ra, 232Th and 40K were 20.64, 30.50 and 295.19 Bq kg-1, respectively. The absorbed dose rate in air at 1 m above ground level, the annual effective dose and the gamma index were determined with the aim to assess the possible radiological impact on inhabitants of dwellings built using such rocks. The mean value of the absorbed dose rate, the annual effective dose and the gamma index (Iγ) was 36.36 nGy h-1, 40.79 μSv y-1 and 0.51 μSv y-1, respectively. Radium equivalent activities, and external and internal hazard indices, were also calculated. These data indicated that the area of study lies within areas recognized as normal background radiation and the granite rocks are safe to be used as building material and other structural purposes.
Radiological Defense. Volume 4. An Introduction to Radiological Instruments for Military Use
1950-01-01
alpha admission. Thin mica and stretched nylon walls with nonmetals of low atomic number and and rubber hydrochloride films about 5 microns writing...individual pulse. This process is called qu •,cIh1ng and can be ac- R, 5ME.OH, , • .. complished by using external electronic methods ’-""::_:-:Ž-:- " or...counter tubes field survey work. Mica windows down to 0.5 )resentliy employed in survey meters are " inch in mg/cm 2 are available, although in normal
Radiological controls integrated into design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kindred, G.W.
1995-03-01
Radiological controls are required by law in the design of commercial nuclear power reactor facilities. These controls can be relatively minor or significant, relative to cost. To ensure that radiological controls are designed into a project, the health physicist (radiological engineer) must be involved from the beginning. This is especially true regarding keeping costs down. For every radiological engineer at a nuclear power plant there must be fifty engineers of other disciplines. The radiological engineer cannot be an expert on every discipline of engineering. However, he must be knowledgeable to the degree of how a design will impact the facilitymore » from a radiological perspective. This paper will address how to effectively perform radiological analyses with the goal of radiological controls integrated into the design package.« less
100 classic papers of interventional radiology: A citation analysis.
Crockett, Matthew T; Browne, Ronan Fj; MacMahon, Peter J; Lawler, Leo
2015-04-28
To define the 100 citation classic papers of interventional radiology. Using the database of Journal Citation Reports the 40 highest impact factor radiology journals were chosen. From these journals the 100 most cited interventional radiology papers were chosen and analysed. The top paper received 2497 citations and the 100(th) paper 200 citations. The average number of citations was 320. Dates of publication ranged from 1953 - 2005. Most papers originated in the United States (n = 67) followed by Italy (n = 20) and France (n = 10). Harvard University (n = 18) and Osped Civile (n = 11) were the most prolific institutions. Ten journals produced all of the top 100 papers with "Radiology" and "AJR" making up the majority. SN Goldberg and T Livraghi were the most prolific authors. Nearly two thirds of the papers (n = 61) were published after 1990. This analysis identifies many of the landmark interventional radiology papers and provides a fascinating insight into the changing discourse within the field. It also identifies topics, authors and institutions which have impacted greatly on the specialty.
78 FR 56775 - Waste Confidence-Continued Storage of Spent Nuclear Fuel
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-13
... radiological impacts of spent nuclear fuel and high-level waste disposal. DATES: Submit comments on the... determination. The ``Offsite radiological impacts of spent nuclear fuel and high-level waste disposal'' issue.... Geologic Repository--Technical Feasibility and Availability C3. Storage of Spent Nuclear Fuel C3.a...
Kourdioukova, Elena V; Verstraete, Koenraad L; Valcke, Martin
2011-06-01
The aim of this research was to explore (1) clinical years students' perceptions about radiology case-based learning within a computer supported collaborative learning (CSCL) setting, (2) an analysis of the collaborative learning process, and (3) the learning impact of collaborative work on the radiology cases. The first part of this study focuses on a more detailed analysis of a survey study about CSCL based case-based learning, set up in the context of a broader radiology curriculum innovation. The second part centers on a qualitative and quantitative analysis of 52 online collaborative learning discussions from 5th year and nearly graduating medical students. The collaborative work was based on 26 radiology cases regarding musculoskeletal radiology. The analysis of perceptions about collaborative learning on radiology cases reflects a rather neutral attitude that also does not differ significantly in students of different grade levels. Less advanced students are more positive about CSCL as compared to last year students. Outcome evaluation shows a significantly higher level of accuracy in identification of radiology key structures and in radiology diagnosis as well as in linking the radiological signs with available clinical information in nearly graduated students. No significant differences between different grade levels were found in accuracy of using medical terminology. Students appreciate computer supported collaborative learning settings when tackling radiology case-based learning. Scripted computer supported collaborative learning groups proved to be useful for both 5th and 7th year students in view of developing components of their radiology diagnostic approaches. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Population dose near the Semipalatinsk test site.
Hille, R; Hill, P; Bouisset, P; Calmet, D; Kluson, J; Seisebaev, A; Smagulov, S
1998-10-01
To determine the consequences of atmospheric atomic bomb tests for the population in the surroundings of the former nuclear weapons test site near Semipalatinsk in Kazakhstan, a pilot study was performed by an international cooperation between Kazakh, French, Czech and German institutions at two villages, Mostik and Maisk. Together with Kazakh scientists, eight experts from Europe carried out a field mission in September 1995 to assess, within the framework of a NATO supported project, the radiological situation as far as external doses, environmental contamination and body burden of man were concerned. A summary of the results obtained is presented. The actual radiological situation near the test site is characterized by fallout contaminations. Cs was found in upper soil layers in concentrations similar to those of the global fallout. Also Sr, Am and Co were observed. The resulting present dose to the population is low. Mean external doses from soil contamination for Maisk and Mostik (0.60-0.63 mSv/year) presently correspond to mean external doses in normal environments. Mean values of the annual internal doses observed in these two villages are below 2 microSv/year for 90Sr. For other radionuclides the internal doses are also negligible.
Treatment of unstable intraarticular fracture of distal radius: POP casting with external fixation.
ur Rahman, Obaid; Khan, Mohammad Qadeem; Rasheed, Haroon; Ahmad, Saleem
2012-04-01
To compare radiological and functional outcome of external fixation and distraction with conservative Plaster of Paris (POP) cast for unstable intra-articular fractures of the distal radius. The study was conducted on 60 patients with unstable intra-articular fracture of distal radius who reported to emergency or outpatient Orthopaedic Surgery department of Benazir Bhutto Hospital, Rawalpindi, between March and August 2007. They were divided into two equal groups: Group A and Group B, treated by Plaster of Paris cast, and external fixation with distraction respectively. The functional outcome in terms of freedom from pain, range of movement, grip power and deformity, and the radiological outcome of radial length, incongruity and radio-ulnar joint position were analysed at three months follow-up using a 3-point scoring scale. In Group A, 1 (3%) patient showed excellent result, 8 (27%) patients good results, 19 (63%) patients fair results and 2 (7%) patients poor result. In Group B, 14 (47%) patients showed excellent results, 11 (37%) patients good results, 4 (13%) patients fair results and 1 (3%) patient poor result. The outcome score of the Group B patients was significantly better compared to the Group A patients (p value < 0.05). External fixation has definite advantages over conventional Plaster of Paris cast in the treatment of unstable intra-articular fractures of distal radius.
Li, Jia; Sun, Jin-Ke; Wang, Chen-Lin
2017-06-25
To investigate surgical skills and clinical effects of manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures. From May 2013 to October 2016, 35 patients with grade IV supination-external rotation ankle fractures were treated with percutaneous Kirschner wire internal fixation, involving 22 males and 13 females with an average age of 38.2 years ranged from 18 to 65 years old. The time from injury to operation ranged from 2 h to 10 d with an average of 5 d. Reduction quality was assessed by Burwell-Charnley radiological criteria. Baird-Jackson ankle scoring system was used to assess clinical effects. Thirty-three patients were followed up from 10 to 28 months with an average of 14 months. Fracture healing time ranged from 10 to 18 weeks with an average of 12 weeks. According to Burwell-Charnley radiological criteria, 30 cases were obtained anatomic reduction, 3 cases moderate. According to Baird-Jackson ankle scoring system, total score was 93.8±5.4, 17 cases got excellent result, 12 good, 2 fair and 2 poor. Manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures has advantages of reliable efficacy, less complications. But higher require techniques were required for closed reduction. It is not suitable for severe crushed fracture and compressive articular surface fracture.
Open Access Journal Policies: A Systematic Analysis of Radiology Journals.
Narayan, Anand; Lobner, Katie; Fritz, Jan
2018-02-01
The open access movement has pushed for greater access to scientific knowledge by expanding access to scientific journal articles. There is limited information about the extent to which open access policies have been adopted by radiology journals. We performed a systematic analysis to ascertain the proportion of radiology journals with open access options. A search was performed with the assistance of a clinical informationist. Full and mixed English-language diagnostic and interventional radiology Web of Science journals (impact factors > 1.0) were included. Nuclear medicine, radiation oncology, physics, and solicitation-only journals were excluded. Primary outcome was open access option (yes or no) with additional outcomes including presence or absence of embargo, complete or partial copyright transfer, publication fees, and self-archiving policies. Secondary outcomes included journal citations, journal impact factors, immediacy, Eigenfactor, and article influence scores. Independent double readings were performed with differences resolved by consensus, supplemented by contacting editorial staff at each journal. In all, 125 journals were identified; review yielded 49 journals (39%, mean impact factor of 2.61). Thirty-six of the journals had open access options (73.4%), and four journals were exclusively open access (8.2%). Twelve-month embargoes were most commonly cited (90.6%) with 28.6% of journals stating that they did not require a complete transfer of copyright. Prices for open access options ranged from $750 to $4,000 (median $3,000). No statistically significant differences were found in journal impact measures comparing journals with open access options to journals without open access options. Diagnostic and interventional radiology journals have widely adopted open access options with a few radiology journals being exclusively open access. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Mandibular Third Molar Impaction: Review of Literature and a Proposal of a Classification
Daugela, Povilas
2013-01-01
ABSTRACT Objectives The purpose of present article was to review impacted mandibular third molar aetiology, clinical anatomy, radiologic examination, surgical treatment and possible complications, as well as to create new mandibular third molar impaction and extraction difficulty degree classification based on anatomical and radiologic findings and literature review results. Material and Methods Literature was selected through a search of PubMed, Embase and Cochrane electronic databases. The keywords used for search were mandibular third molar, impacted mandibular third molar, inferior alveolar nerve injury third molar, lingual nerve injury third molar. The search was restricted to English language articles, published from 1976 to April 2013. Additionally, a manual search in the major anatomy and oral surgery journals and books was performed. The publications there selected by including clinical and human anatomy studies. Results In total 75 literature sources were obtained and reviewed. Impacted mandibular third molar aetiology, clinical anatomy, radiographic examination, surgical extraction of and possible complications, classifications and risk factors were discussed. New mandibular third molar impaction and extraction difficulty degree classification based on anatomical and radiologic findings and literature review results was proposed. Conclusions The classification proposed here based on anatomical and radiological impacted mandibular third molar features is promising to be a helpful tool for impacted tooth assessment as well as for planning for surgical operation. Further clinical studies should be conducted for new classification validation and reliability evaluation. PMID:24422029
INTERNAL HAZARDS ANALYSIS FOR LICENSE APPLICATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
R.J. Garrett
2005-02-17
The purpose of this internal hazards analysis is to identify and document the internal hazards and potential initiating events associated with preclosure operations of the repository at Yucca Mountain. Internal hazards are those hazards presented by the operation of the facility and by its associated processes that can potentially lead to a radioactive release or cause a radiological hazard. In contrast to external hazards, internal hazards do not involve natural phenomena and external man-made hazards. This internal hazards analysis was performed in support of the preclosure safety analysis and the License Application for the Yucca Mountain Project. The methodology formore » this analysis provides a systematic means to identify internal hazards and potential initiating events that may result in a radiological hazard or radiological release during the repository preclosure period. These hazards are documented in tables of potential internal hazards and potential initiating events (Section 6.6) for input to the repository event sequence categorization process. The results of this analysis will undergo further screening and analysis based on the criteria that apply to the performance of event sequence analyses for the repository preclosure period. The evolving design of the repository will be re-evaluated periodically to ensure that internal hazards that have not been previously evaluated are identified.« less
The impact of the Patient Protection and Affordable Care Act on radiology: beyond reimbursement.
Krishnaraj, Arun; Norbash, Alexander; Allen, Bibb; Ellenbogen, Paul H; Kazerooni, Ella A; Thorwarth, William; Weinreb, Jeffrey C
2015-01-01
The 2014 ACR Forum focused on the noneconomic implications of the Affordable Care Act on the field of radiology, with specific attention to the importance of the patient experience, the role of radiology in public and population health, and radiology's role in the effort to lower overall health care costs. The recommendations generated from the Forum seek to inform ACR leadership on the best strategies to pursue to best prepare the radiology community for the rapidly evolving health care landscape. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Radiological impact of airborne effluents of coal and nuclear plants.
McBride, J P; Moore, R E; Witherspoon, J P; Blanco, R E
1978-12-08
Radiation doses from airborne effluents of model coal-fired and nuclear power plants (1000 megawatts electric) are compared. Assuming a 1 percent ash release to the atmosphere (Environmental Protection Agency regulation) and 1 part per million of uranium and 2 parts per million of thorium in the coal (approximately the U.S. average), population doses from the coal plant are typically higher than those from pressurized-water or boiling-water reactors that meet government regulations. Higher radionuclide contents and ash releases are common and would result in increased doses from the coal plant. The study does not assess the impact of non-radiological pollutants or the total radiological impacts of a coal versus a nuclear economy.
Cost analysis of equipment failure of a radiology department and possible choices about maintenance.
Grisi, Guido; Dalla Palma, Ludovico; Rimondini, Allesandra; Palmolungo, Chiara; Cuttin Zernich, Roberto; Pozzi Mucelli, Roberto
2002-01-01
Our aim was to evaluate the economic impact of equipment failures in a radiology department with a view to guiding maintenance policy decisions. We assessed the negative economic impact caused by the interruption of activity of a radiodiagnostics section due to equipment failure, taking into account: the effects occurring during the first day of equipment down-time (assuming that the equipment failure occurs in the middle of the shift) and the effects during the following days until the repair of the failure; the effects occurring in the short- and long-term. To exemplify the negative impact of inactivity due to equipment failure, we chose three radiology sections with different levels of technological and operational complexity (chest radiology, gastrointestinal radiology and remote-controlled diagnostics). For each, we evaluated the loss of contribution margin and the idle capacity costs (short- and long-term impact). The negative economic effects were: for thoracic radiology, 496,77 Euro in the first day, and 30,99 Euro from the second day onwards; for gastrointestinal radiology, 526,40 Euro for the first day, and 730,39 Euro from the second day onwards; for remote-controlled diagnostics, 786,25 Euro for the first day, and 927,67 Euro from the second days onwards. Our results indicate that the level of idle capacity costs (mainly equipment and staff) increases with the complexity of the equipment, whereas the contribution margin appears to fluctuate, because the charges are state-imposed and do not vary with the complexity of equipment. Moreover, our analysis shows that if the workload of a broken machine can easily be assigned to an additional shift using another machine, losses are considerably reduced from the second day onwards. Once the negative economic impact of equipment failures has been evaluated, the second step is to choose the best kind of maintenance. A sound calculation of the economic impact of equipment failures is very useful for guiding the head of department and the hospital manager in deciding whether to purchase maintenance services (or a long-term guarantee) from the equipment manufacturer, to set up an auxiliary centre for maintenance and repair, or to purchase a third-party maintenance contract.
Strategic Expansion Models in Academic Radiology.
Natesan, Rajni; Yang, Wei T; Tannir, Habib; Parikh, Jay
2016-03-01
In response to economic pressures, academic institutions in the United States and their radiology practices, are expanding into the community to build a larger network, thereby driving growth and achieving economies of scale. These economies of scale are being achieved variously via brick-and-mortar construction, community practice acquisition, and partnership-based network expansion. We describe and compare these three expansion models within a 4-part framework of: (1) upfront investment; (2) profitability impact; (3) brand impact; and (4) risk of execution. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
The Use of Twitter by Radiology Journals: An Analysis of Twitter Activity and Impact Factor.
Kelly, Brendan S; Redmond, Ciaran E; Nason, Gregory J; Healy, Gerard M; Horgan, Niall A; Heffernan, Eric J
2016-11-01
Medical journals use social media as a means to disseminate new research and interact with readers. The microblogging site Twitter is one such platform. The aim of this study was to analyze the recent use of Twitter by the leading radiology journals. The top 50 journals by Impact Factor were included. Twitter profiles associated with these journals, or their corresponding societies, were identified. Whether each journal used other social media platforms was also recorded. Each Twitter profile was analyzed over a one-year period, with data collected via Twitonomy software. Klout scores of social media influence were calculated. Results were analyzed in SPSS using Student's t test, Fisher contingency tables, and Pearson correlations to identify any association between social media interaction and Impact Factors of journals. Fourteen journals (28%) had dedicated Twitter profiles. Of the 36 journals without dedicated Twitter profiles, 25 (50%) were associated with societies that had profiles, leaving 11 (22%) journals without a presence on Twitter. The mean Impact Factor of all journals was 3.1 ± 1.41 (range, 1.7-6.9). Journals with Twitter profiles had higher Impact Factors than those without (mean, 3.37 vs 2.14; P < .001). There was no statistically significant difference between the Impact Factors of the journals with dedicated Twitter profiles and those associated with affiliated societies (P = .47). Since joining Twitter, 7 of the 11 journals (64%) experienced increases in Impact Factor. A greater number of Twitter followers was correlated with higher journal Impact Factor (R 2 = 0.581, P = .029). The investigators assessed the prevalence and activity of the leading radiology journals on Twitter. Radiology journals with Twitter profiles have higher Impact Factors than those without profiles, and the number of followers of a journal's Twitter profile is positively associated with Impact Factor. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Chen, Po-Hao; Loehfelm, Thomas W; Kamer, Aaron P; Lemmon, Andrew B; Cook, Tessa S; Kohli, Marc D
2016-12-01
The residency review committee of the Accreditation Council of Graduate Medical Education (ACGME) collects data on resident exam volume and sets minimum requirements. However, this data is not made readily available, and the ACGME does not share their tools or methodology. It is therefore difficult to assess the integrity of the data and determine if it truly reflects relevant aspects of the resident experience. This manuscript describes our experience creating a multi-institutional case log, incorporating data from three American diagnostic radiology residency programs. Each of the three sites independently established automated query pipelines from the various radiology information systems in their respective hospital groups, thereby creating a resident-specific database. Then, the three institutional resident case log databases were aggregated into a single centralized database schema. Three hundred thirty residents and 2,905,923 radiologic examinations over a 4-year span were catalogued using 11 ACGME categories. Our experience highlights big data challenges including internal data heterogeneity and external data discrepancies faced by informatics researchers.
10 CFR 72.126 - Criteria for radiological protection.
Code of Federal Regulations, 2014 CFR
2014-01-01
.... Radiation protection systems must be provided for all areas and operations where onsite personnel may be exposed to radiation or airborne radioactive materials. Structures, systems, and components for which..., fabricated, located, shielded, controlled, and tested so as to control external and internal radiation...
10 CFR 72.126 - Criteria for radiological protection.
Code of Federal Regulations, 2012 CFR
2012-01-01
.... Radiation protection systems must be provided for all areas and operations where onsite personnel may be exposed to radiation or airborne radioactive materials. Structures, systems, and components for which..., fabricated, located, shielded, controlled, and tested so as to control external and internal radiation...
10 CFR 72.126 - Criteria for radiological protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... Radiation protection systems must be provided for all areas and operations where onsite personnel may be exposed to radiation or airborne radioactive materials. Structures, systems, and components for which..., fabricated, located, shielded, controlled, and tested so as to control external and internal radiation...
10 CFR 72.126 - Criteria for radiological protection.
Code of Federal Regulations, 2013 CFR
2013-01-01
.... Radiation protection systems must be provided for all areas and operations where onsite personnel may be exposed to radiation or airborne radioactive materials. Structures, systems, and components for which..., fabricated, located, shielded, controlled, and tested so as to control external and internal radiation...
Malignant external otitis: The diagnostic value of bone scintigraphy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ostfeld, E.; Aviel, A.; Pelet, D.
1981-06-01
Technetium99m Methylene Diphosphate bone scintigraphy (BS) of the skull was performed in three patients with malignant external otitis (MEO). Pathological uptake of the radioisotope in the mastoid region was found during the early stages of MEO updating radiologic findings. The extent of the radioisotope accumulation during the early stages of MEO indicates that the actual tissue damage exceeds the clinical estimation. The follow-up BS findings correlate well with the clinical course of MEO indicating either healing or extension to the base of skull.
2013-06-14
ever-evolving contemporary nature of external and internal threats to the safety and security of the American homeland, it becomes increasingly...Major Justin P. Hurt, 146 pages. With the ever-evolving contemporary nature of external and internal threats to the safety and security of the American...HAZMAT Hazardous Materials HRF Homeland Response Force HSPD Homeland Security Presidential Directive JFHQ Joint Force
Citation Impact of Collaboration in Radiology Research.
Rosenkrantz, Andrew B; Parikh, Ujas; Duszak, Richard
2018-02-01
Team science involving multidisciplinary and multi-institutional collaboration is increasingly recognized as a means of strengthening the quality of scientific research. The aim of this study was to assess associations between various forms of collaboration and the citation impact of published radiology research. In 2010, 876 original research articles published in Academic Radiology, the American Journal of Roentgenology, JACR, and Radiology were identified with at least one radiology-affiliated author. All articles were manually reviewed to extract features related to all authors' disciplines and institutions. Citations to these articles through September 2016 were extracted from Thomson Reuters Web of Science. Subsequent journal article citation counts were significantly higher (P < .05) for original research articles with at least seven versus six or fewer authors (26.2 ± 30.8 versus 20.3 ± 23.1, respectively), with authors from multiple countries versus from a single country (32.3 ± 39.2 versus 22.0 ± 25.0, respectively), with rather than without a nonuniversity collaborator (28.7 ± 38.6 versus 22.4 ± 24.9, respectively), and with rather than without a nonclinical collaborator (26.5 ± 33.1 versus 21.9 ± 24.4, respectively). On multivariate regression analysis, the strongest independent predictors of the number of citations were authors from multiple countries (β = 9.14, P = .002), a nonuniversity collaborator (β = 4.80, P = .082), and at least seven authors (β = 4.11, P = .038). With respect to subsequent journal article citations, various forms of collaboration are associated with greater scholarly impact of published radiology research. To enhance the relevance of their research, radiology investigators are encouraged to pursue collaboration across traditional disciplinary, institutional, and geographic boundaries. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
[Radiology in managed care environment: opportunities for cost savings in an HMO].
Schmidt, C; Mohr, A; Möller, J; Levin-Scherz, J; Heller, M
2003-09-01
A large regional health plan in the Northeastern United States noted that its radiology costs were increasing more than it anticipated in its pricing, and noted further that other similar health plans in markets with high managed care penetration had significantly lower expenses for radiology services. This study describes the potential areas of improvement and managed care techniques that were implemented to reduce costs and reform processes. We performed an in-depth analysis of financial data, claims logic, contracting with provider units and conducted interviews with employees, to identify potential areas of improvement and cost reduction. A detailed market analysis of the environment, competitors and vendors was accompanied by extensive literature, Internet and Medline search for comparable projects. All data were docu-mented in Microsoft Excel(R) and analyzed by non-parametric tests using SPSS(R) 8.0 (Statistical Package for the Social Sciences) for Windows(R). The main factors driving the cost increases in radiology were divided into those internal or external to the HMO. Among the internal factors, the claims logic was allowing overpayment due to limitations of the IT system. Risk arrangements between insurer and provider units (PU) as well as the extent of provider unit management and administration showed a significant correlation with financial performance in terms of variance from budget. Among the external factors, shared risk arrangements between HMO and provider unit were associated with more efficient radiology utilization and overall improvement in financial performance. PU with full-time management had significantly less variance from their budget than those without. Finally, physicians with imaging equipment in their offices ordered up to 4 to 5 times more imaging procedures than physicians who did not perform imaging studies themselves. We identified initiatives with estimated potential savings of approximately $ 5.5 million. Some of these initiatives are similar to the reforms to reduce cost and improve quality that are already implemented or proposed within the German healthcare system.
Gusev, B I; Abylkassimova, Z N; Apsalikov, K N
1997-09-01
As a result of atmospheric nuclear tests at the Semipalatinsk test site 'Polygon', adjacent territories were contaminated by radionuclide fallout. The population of some districts in the Semipalatinsk oblast were exposed to elevated levels of radiation. Contamination and exposure mostly resulted from early atmospheric tests. The radiological situation of the Semipalatinsk oblast is described. Effective dose estimates due to external and internal exposure attributable to the 1949 and 1953 tests in villages near the Polygon range from 70 mSv to 4470 mSv.
Hanford radiological protection support services annual report for 1994
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyon, M.; Bihl, D.E.; Fix, J.J.
1995-06-01
Various Hanford Site radiation protection services provided by the Pacific Northwest Laboratory for the US Department of Energy Richland Operations Office and Hanford contractors are described in this annual report for the calendar year 1994. These activities include external dosimetry measurements and evaluations, internal dosimetry measurements and evaluations, in vivo measurements, radiological record keeping, radiation source calibration, and instrument calibration and evaluation. For each of these activities, the routine program and any program changes or enhancements are described, as well as associated tasks, investigations, and studies. Program- related publications, presentations, and other staff professional activities are also described.
Hanford radiological protection support services. Annual report for 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyon, M.; Bihl, D.E.; Carbaugh, E.H.
1996-05-01
Various Hanford Site radiation protection services provided by the Pacific Northwest National Laboratory for the U.S. Department of Energy Richland Operations Office and Hanford contractors are described in this annual report for calendar year 1995. These activities include external dosimetry measurements and evaluations, internal dosimetry measurements and evaluations, in vivo measurements, radiological record keeping, radiation source calibration, and instrument calibration and evaluation. For each of these activities, the routine program and any program changes or enhancements are described, as well as associated tasks, investigations, and studies. Program-related publications, presentations, and other staff professional activities are also described.
Radiology education: a glimpse into the future.
Scarsbrook, A F; Graham, R N J; Perriss, R W
2006-08-01
The digital revolution in radiology continues to advance rapidly. There are a number of interesting developments within radiology informatics which may have a significant impact on education and training of radiologists in the near future. These include extended functionality of handheld computers, web-based skill and knowledge assessment, standardization of radiological procedural training using simulated or virtual patients, worldwide videoconferencing via high-quality health networks such as Internet2 and global collaboration of radiological educational resources via comprehensive, multi-national databases such as the medical imaging resource centre initiative of the Radiological Society of North America. This article will explore the role of e-learning in radiology, highlight a number of useful web-based applications in this area, and explain how the current and future technological advances might best be incorporated into radiological training.
Science and Technology Policy: Issues for the 109th Congress
2006-09-01
biological weapons . In May 2004, several higher education organizations released a combined statement on the impact of the new visa policies on higher...9 Chemical, Biological , Radiological, and Nuclear Terrorism Countermeasures R&D...Quality Chemical, Biological , Radiological, and Nuclear Terrorism Countermeasures R&D Federal chemical, biological , radiological, and nuclear (CBRN
Manned space flight nuclear system safety. Volume 6: Space base nuclear system safety plan
NASA Technical Reports Server (NTRS)
1972-01-01
A qualitative identification of the steps required to assure the incorporation of radiological system safety principles and objectives into all phases of a manned space base program are presented. Specific areas of emphasis include: (1) radiological program management, (2) nuclear system safety plan implementation, (3) impact on program, and (4) summary of the key operation and design guidelines and requirements. The plan clearly indicates the necessity of considering and implementing radiological system safety recommendations as early as possible in the development cycle to assure maximum safety and minimize the impact on design and mission plans.
Lehman, V T; Doolittle, D A; Hunt, C H; Eckel, L J; Black, D F; Schwartz, K M; Diehn, F E
2014-01-01
Descriptions of uncommon diseases with intracranial imaging abnormalities are often difficult to find in the radiology literature. We hypothesized that reported imaging findings of such conditions in the recent literature were more frequent in clinical compared with radiology journals. PubMed searches from December 1, 2007 to December 1, 2012 were performed for 5 uncommon CNS diseases with intracranial imaging manifestations: 1) Susac syndrome; 2) amyloid β-related angiitis; 3) Parry-Romberg syndrome/en coup de sabre; 4) transient lesion of the splenium of the corpus callosum; and 5) reversible cerebral vasoconstriction syndrome. Articles were classified as a case report, case series, or original research. Journals were categorized as radiology or clinical. The 1- and 5-year Impact Factors of the journals were recorded. Two hundred two articles were identified for the 5 diseases, including 151 (74%) case reports, 26 case series (13%), and 25 original research articles (13%); 179 (89%) were published in nonradiology journals, compared with 23 (11%) in radiology journals. There was no significant difference between the mean 1- and 5-year Impact Factors of the radiology and clinical journals. Recent reports of the selected uncommon diseases with intracranial manifestations are more frequent in clinical journals when compared with dedicated radiology publications. Most publications are case reports. Radiologists should review both radiology and clinical journals when reviewing imaging features of uncommon diseases affecting the brain. Lack of reporting on such disease in the radiology literature may have significant practice, educational, and research implications for the radiology community.
[Teleradiology: threats and opportunities].
Krestin, Gabriel P; Pieterman, Herman
2011-01-01
Radiological interpretation and reporting have become a commodity that may be farmed out elsewhere on the planet: teleradiology. The impact of this development fully depends on our understanding of the role of radiology as a specialty. If radiology is solely defined as the provision of medical image interpretation then commoditization of radiology through teleradiology services will lead to a deterioration in the status of radiologists. They may even become redundant as hospital specialists. However, if radiology is seen in a broader context with much more emphasis on its added value through specialized consultancy, then teleradiology may be an important instrument for improvement and optimalisation of imaging services.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-01-01
Research on the chemical physics of atoms and molecules, especially their interaction with external agents such as photons and electrons is reported. Abstracts of seven individual items from the report were prepared separately for the data base. (GHT)
10 CFR 835.204 - Planned special exposures.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Planned special exposures. 835.204 Section 835.204 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.204 Planned special exposures. (a) A planned special exposure may be authorized for a radiological worker to...
10 CFR 835.204 - Planned special exposures.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Planned special exposures. 835.204 Section 835.204 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.204 Planned special exposures. (a) A planned special exposure may be authorized for a radiological worker to...
10 CFR 835.204 - Planned special exposures.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Planned special exposures. 835.204 Section 835.204 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.204 Planned special exposures. (a) A planned special exposure may be authorized for a radiological worker to...
10 CFR 835.204 - Planned special exposures.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Planned special exposures. 835.204 Section 835.204 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.204 Planned special exposures. (a) A planned special exposure may be authorized for a radiological worker to...
10 CFR 835.204 - Planned special exposures.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Planned special exposures. 835.204 Section 835.204 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.204 Planned special exposures. (a) A planned special exposure may be authorized for a radiological worker to...
Reduction of the posterior pelvic ring by non-invasive stabilisation: a report of two cases.
Qureshi, A; McGee, A; Cooper, J P; Porter, K M
2005-12-01
We demonstrate radiological evidence that an external pelvic splint is effective at reducing open book pelvic fractures. Its use in the pre-hospital and emergency department settings should be encouraged in the initial management and resuscitation of patients with pelvic fractures.
Shekhani, Haris Naseem; Shariff, Shoaib; Bhulani, Nizar; Khosa, Faisal; Hanna, Tarek Noel
2017-12-01
The objective of our study was to investigate radiology manuscript characteristics that influence citation rate, capturing features of manuscript construction that are discrete from study design. Consecutive articles published from January 2004 to June 2004 were collected from the six major radiology journals with the highest impact factors: Radiology (impact factor, 5.076), Investigative Radiology (2.320), American Journal of Neuroradiology (AJNR) (2.384), RadioGraphics (2.494), European Radiology (2.364), and American Journal of Roentgenology (2.406). The citation count for these articles was retrieved from the Web of Science, and 29 article characteristics were tabulated manually. A point-biserial correlation, Spearman rank-order correlation, and multiple regression model were performed to predict citation number from the collected variables. A total of 703 articles-211 published in Radiology, 48 in Investigative Radiology, 106 in AJNR, 52 in RadioGraphics, 129 in European Radiology, and 157 in AJR-were evaluated. Punctuation was included in the title in 55% of the articles and had the highest statistically significant positive correlation to citation rate (point-biserial correlation coefficient [r pb ] = 0.85, p < 0.05). Open access status provided a low-magnitude, but significant, correlation to citation rate (r pb = 0.140, p < 0.001). The following variables created a significant multiple regression model to predict citation count (p < 0.005, R 2 = 0.186): study findings in the title, abstract word count, abstract character count, total number of words, country of origin, and all authors in the field of radiology. Using bibliometric knowledge, authors can craft a title, abstract, and text that may enhance visibility and citation count over what they would otherwise experience.
Kaminski, Michael D; Lee, Sang Don; Magnuson, Matthew
2016-03-15
Nuclear or radiological terrorism in the form of uncontrolled radioactive contamination presents a unique challenge in the field of nuclear decontamination. Potential targets require an immediate decontamination response, or mitigation plan to limit the social and economic impact. To date, experience with urban decontamination of building materials - specifically hard, porous, external surfaces - is limited to nuclear weapon fallout and nuclear reactor accidents. Methods are lacking for performing wide-area decontamination in an urban environment so that in all release scenarios the area may be re-occupied without evaluation and/or restriction. Also lacking is experience in developing mitigation strategies, that is, methods of mitigating contamination and its resultant radiation dose in key areas during the immediate aftermath of an event and after lifesaving operations. To date, the tremendous strategy development effort primarily by the European community has focused on the recovery phase, which extends years beyond the release event. In this review, we summarize the methods and data collected over the past 70 years in the field of hard, external surface decontamination of radionuclide contaminations, with emphasis on methods suitable for response to radiological dispersal devices and their potentially unique physico-chemical characteristics. This review concludes that although a tremendous amount of work has been completed primarily by the European Community (EU) and the United Kingdom (UK), the few studies existing on each technique permit only very preliminary estimates of decontamination factors for various building materials and methods and extrapolation of those values for use in environments outside the EU and UK. This data shortage prevents us from developing an effective and detailed mitigation response plan and remediation effort. Perhaps most importantly, while the data available does include valuable information on the practical aspects of performing the various remediation methods including costs, coverage rates, manpower, pitfalls, etc., it lacks the details on lessons learned, best practices, and standard procedures, for instance, that would be required to develop a mitigation strategy. While the urban decontamination problem is difficult and there is much more research to do, the existing literature provides a framework for a response plan. Using this framework, in conjunction with computer modeling and relevant data collection, can lead to development of appropriate plans and exercises that would permit development of a mitigation and remediation response. Copyright © 2015 Elsevier B.V. All rights reserved.
Radiological incident preparedness: planning at the local level.
Tan, Clive M; Barnett, Daniel J; Stolz, Adam J; Links, Jonathan M
2011-03-01
Radiological terrorism has been recognized as a probable scenario with high impact. Radiological preparedness planning at the federal and state levels has been encouraging, but translating complex doctrines into operational readiness at the local level has proved challenging. Based on the authors' experience with radiological response planning for the City of Baltimore, this article describes an integrated approach to municipal-level radiological emergency preparedness planning, provides information on resources that are useful for radiological preparedness planning, and recommends a step-by-step process toward developing the plan with relevant examples from the experience in Baltimore. Local governmental agencies constitute the first line of response and are critical to the success of the operation. This article is intended as a starting framework for local governmental efforts toward developing a response plan for radiological incidents in their communities.
Radiology applications of financial accounting.
Leibenhaut, Mark H
2005-03-01
A basic knowledge of financial accounting can help radiologists analyze business opportunities and examine the potential impacts of new technology or predict the adverse consequences of new competitors entering their service area. The income statement, balance sheet, and cash flow statement are the three basic financial statements that document the current financial position of the radiology practice and allow managers to monitor the ongoing financial operations of the enterprise. Pro forma, or hypothetical, financial statements can be generated to predict the financial impact of specific business decisions or investments on the profitability of the practice. Sensitivity analysis, or what-if scenarios, can be performed to determine the potential impact of changing key revenue, investment, operating cost or financial assumptions. By viewing radiology as both a profession and a business, radiologists can optimize their use of scarce economic resources and maximize the return on their financial investments.
Cone beam computed tomography of plastinated hearts for instruction of radiological anatomy.
Chang, Chih-Wei; Atkinson, Gregory; Gandhi, Niket; Farrell, Michael L; Labrash, Steven; Smith, Alice B; Norton, Neil S; Matsui, Takashi; Lozanoff, Scott
2016-09-01
Radiological anatomy education is an important aspect of the medical curriculum. The purpose of this study was to establish and demonstrate the use of plastinated anatomical specimens, specifically human hearts, for use in radiological anatomy education. Four human hearts were processed with routine plastination procedures at room temperature. Specimens were subjected to cone beam computed tomography and a graphics program (ER3D) was applied to generate 3D cardiac models. A comparison was conducted between plastinated hearts and their corresponding computer models based on a list of morphological cardiac features commonly studied in the gross anatomy laboratory. Results showed significant correspondence between plastinations and CBCT-generated 3D models (98 %; p < .01) for external structures and 100 % for internal cardiac features, while 85 % correspondence was achieved between plastinations and 2D CBCT slices. Complete correspondence (100 %) was achieved between key observations on the plastinations and internal radiological findings typically required of medical student. All pathologic features seen on the plastinated hearts were also visualized internally with the CBCT-generated models and 2D slices. These results suggest that CBCT-derived slices and models can be successfully generated from plastinated material and provide accurate representations for radiological anatomy education.
Lim-Dunham, Jennifer E; Ensminger, David C; McNulty, John A; Hoyt, Amy E; Chandrasekhar, Arcot J
2016-02-01
The principles of Collins' cognitive apprenticeship model were used to design a radiology curriculum in which medical students practice radiological skills using online case-based modules. The modules are embedded within clinical third-year clerkships, and students are provided with personalized feedback from the instructors. We describe the development of the vertical online radiology curriculum and evaluate its impact on student achievement and learning process using a mixed method approach. The curriculum was developed over a 2-year period. Student participation was voluntary in the first year and mandatory in the second year. For quantitative curriculum evaluation, student metrics for voluntary versus mandatory groups were assessed using independent sample t tests and variable entry method regression analysis. For qualitative analysis, responses from a survey of students about the value of the curriculum were organized into defined themes using consensus coding. Mandatory participation significantly improved (p = .001) the mean radiology examination score (82 %) compared to the voluntary group (73%), suggesting that mandatory participation had a beneficial effect on student performance. Potential preexisting differences in underlying general academic performance were accounted for by including mean basic science grades as the first variable in the regression model. The significant increase in R(2) from .16 to .28 when number of radiology cases completed was added to the original model, and the greater value of the standardized beta for this variable, suggest that the curriculum made a significant contribution to students' radiology examination scores beyond their baseline academic performance. Five dominant themes about curricular characteristics that enhanced student learning and beneficial outcomes emerged from consensus coding. These themes were (1) self-paced design, (2) receiving feedback from faculty, (3) clinical relevance of cases, (4) gaining confidence in interpreting radiological images, and (5) transfer of conceptual knowledge to actual practice. The vertically integrated online radiology curriculum can positively impact student performance and learning process in the context of the cognitive apprenticeship model. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Distribution of scholarly publications among academic radiology departments.
Morelli, John N; Bokhari, Danial
2013-03-01
The aim of this study was to determine whether the distribution of publications among academic radiology departments in the United States is Gaussian (ie, the bell curve) or Paretian. The search affiliation feature of the PubMed database was used to search for publications in 3 general radiology journals with high Impact Factors, originating at radiology departments in the United States affiliated with residency training programs. The distribution of the number of publications among departments was examined using χ(2) test statistics to determine whether it followed a Pareto or a Gaussian distribution more closely. A total of 14,219 publications contributed since 1987 by faculty members in 163 departments with residency programs were available for assessment. The data acquired were more consistent with a Pareto (χ(2) = 80.4) than a Gaussian (χ(2) = 659.5) distribution. The mean number of publications for departments was 79.9 ± 146 (range, 0-943). The median number of publications was 16.5. The majority (>50%) of major radiology publications from academic departments with residency programs originated in <10% (n = 15 of 178) of such departments. Fifteen programs likewise produced no publications in the surveyed journals. The number of publications in journals with high Impact Factors published by academic radiology departments more closely fits a Pareto rather than a normal distribution. Copyright © 2013 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Radiological impact of natural radionuclides from soils of Salamanca, Mexico.
Mandujano-García, C D; Sosa, M; Mantero, J; Costilla, R; Manjón, G; García-Tenorio, R
2016-11-01
Salamanca is the centre of a large industrial complex associated with the production and refining of oil-derived products in the state of Guanajuato, Mexico. The city also hosts a large chemical industry, and in past years a major fertilizer industry. All of them followed NORM (naturally occurring radioactive materials) industrial activities, where either raw materials or residues enriched in natural radionuclides are handled or generated, which can have an environmental radiological impact on their environmental compartments (e.g. soils and aquatic systems). In this study, activity concentrations of radionuclides from the 238 U and 232 Th natural series present in superficial urban soils surrounding an industrial complex in Salamanca, México, have been determined to analyse the possible environmental radiological impact of some of the industrial activities. The alpha-particle and gamma-ray spectrometry is used for the radiometric characterization. The results revealed the presence of 10-42, 11-51 and 178-811Bq/kg of 238 U, 232 Th and 40 K, respectively, without any clear anthropogenic increment in relation to the values normally found in unaffected soils. Thus, the radioactive impact of the industrial activities on the surrounding soils can be evaluated as very low, representing no radiological risk for the health of the population. Copyright © 2016 Elsevier Ltd. All rights reserved.
100 classic papers of interventional radiology: A citation analysis
Crockett, Matthew T; Browne, Ronan FJ; MacMahon, Peter J; Lawler, Leo
2015-01-01
AIM: To define the 100 citation classic papers of interventional radiology. METHODS: Using the database of Journal Citation Reports the 40 highest impact factor radiology journals were chosen. From these journals the 100 most cited interventional radiology papers were chosen and analysed. RESULTS: The top paper received 2497 citations and the 100th paper 200 citations. The average number of citations was 320. Dates of publication ranged from 1953 - 2005. Most papers originated in the United States (n = 67) followed by Italy (n = 20) and France (n = 10). Harvard University (n = 18) and Osped Civile (n = 11) were the most prolific institutions. Ten journals produced all of the top 100 papers with “Radiology” and “AJR” making up the majority. SN Goldberg and T Livraghi were the most prolific authors. Nearly two thirds of the papers (n = 61) were published after 1990. CONCLUSION: This analysis identifies many of the landmark interventional radiology papers and provides a fascinating insight into the changing discourse within the field. It also identifies topics, authors and institutions which have impacted greatly on the specialty. PMID:25918585
Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.
2018-01-01
Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750
Monte Carlo Simulations for Homeland Security Using Anthropomorphic Phantoms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burns, Kimberly A.
A radiological dispersion device (RDD) is a device which deliberately releases radioactive material for the purpose of causing terror or harm. In the event that a dirty bomb is detonated, there may be airborne radioactive material that can be inhaled as well as settle on an individuals leading to external contamination.
Sahin, Latife; Hafızoğlu, Nurgül; Çetinkaya, Hakan; Manisa, Kaan; Bozkurt, Engin; Biçer, Ahmet
2017-05-01
The analysis of natural radioactivity from 238 U, 232 Th and 40 K in 357 soil samples collected from the province of Kütahya was carried out using a NaI(Tl) gamma-ray spectroscopy system at the Nuclear Physics Research Laboratory, Dumlupınar University, Kütahya, Turkey. The specific activities of 238 U, 232 Th and 40 K in the soil samples were evaluated. From the activity concentrations of 238 U, 232 Th and 40 K, the total absorbed outdoor gamma-ray dose rates and the corresponding annual effective dose rates were determined. The corresponding values of the external and internal hazard indices of all the soil samples were also calculated. The external gamma-ray dose rate at 1 m above the ground was directly measured at each collected soil sample location. The results obtained in this study were compared within the limits of values obtained in other cities of Turkey, those in other countries. Radiological maps of Kütahya Province were constructed from the results of this study.
Qualification tests for {sup 192}Ir sealed sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iancso, Georgeta, E-mail: georgetaiancso@yahoo.com; Iliescu, Elena, E-mail: georgetaiancso@yahoo.com; Iancu, Rodica, E-mail: georgetaiancso@yahoo.com
This paper describes the results of qualification tests for {sup 192}Ir sealed sources, available in Testing and Nuclear Expertise Laboratory of National Institute for Physics and Nuclear Engineering 'Horia Hulubei' (I.F.I.N.-HH), Romania. These sources had to be produced in I.F.I.N.-HH and were tested in order to obtain the authorization from The National Commission for Nuclear Activities Control (CNCAN). The sources are used for gammagraphy procedures or in gammadefectoscopy equipments. Tests, measurement methods and equipments used, comply with CNCAN, AIEA and International Quality Standards and regulations. The qualification tests are: 1. Radiological tests and measurements: dose equivalent rate at 1 m;more » tightness; dose equivalent rate at the surface of the transport and storage container; external unfixed contamination of the container surface. 2. Mechanical and climatic tests: thermal shock; external pressure; mechanic shock; vibrations; boring; thermal conditions for storage and transportation. Passing all tests, it was obtained the Radiological Security Authorization for producing the {sup 192}Ir sealed sources. Now IFIN-HH can meet many demands for this sealed sources, as the only manufacturer in Romania.« less
Radiological environment within an NPP after a severe nuclear accident
NASA Astrophysics Data System (ADS)
Andgren, Karin; Fritioff, Karin; Buhr, Anna Maria Blixt; Huutoniemi, Tommi
2017-09-01
The radiological environment following a severe nuclear accident can be visualised on building layouts. The direct radiation in an area (or room) can be visualized on the layout by a colouring scheme depending on the dose rate level (for example orange for high gamma dose rate level and purple for an intermediate gamma dose rate level). Following the Fukushima accident, a need for update of these layouts has been identified at the Swedish nuclear power plant of Forsmark. Shielding calculations for areas where access is desired for severe accident management have been performed. Many different sources of radiation together with different types of shielding material contribute to the dose that would be received by a person entering the area. External radiation from radioactivity within e.g. pipes and components is considered and also external radiation from radioactivity in the air (originating from diffuse leakage of the containment atmosphere). Results are presented as dose rates for relevant dose points together with a method for estimating the dose rate levels for each of the rooms of the reactor building.
Brandon, Catherine J; Mullan, Patricia B
2013-03-01
To better prepare radiology residents for providing care within the context of the larger health care system, this study evaluated the feasibility and impact of a curriculum to enhance radiology residents' understanding and ability to apply concepts from medical management and industrial and operational engineering to systems-based practice problems in radiology practice. A multiprofessional team including radiology, medical education, and industrial and operational engineering professionals collaborated in developing a seven-module curriculum, including didactic lectures, interactive large-group analysis, and small-group discussions with case-based radiology examples, which illustrated real-life management issues and the roles physicians held. Residents and faculty participated in topic selection. Pre- and post-instruction formative assessments were administered, and results were shared with residents during teaching sessions. Attendance and participation in case-based scenario resolutions indicate the feasibility and impact of the interactive curriculum on residents' interest and ability to apply curricular concepts to systems-based practice in radiology. Paired t test analyses (P < .05) and effect sizes showed residents significantly increased their knowledge and ability to apply concepts to systems-based practice issues in radiology. Our iterative curriculum development and implementation process demonstrated need and support for a multiprofessional team approach to teach management and operational engineering concepts. Curriculum topics are congruent with Accreditation Council for Graduate Medical Education requirements for systems-based practice. The case-based curriculum using a mixed educational format of didactic lectures and small-group discussion and problem analysis could be adopted for other radiology programs, for both residents and continuing medical education applications. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Use of the ICRP system for the protection of marine ecosystems.
Telleria, D; Cabianca, T; Proehl, G; Kliaus, V; Brown, J; Bossio, C; Van der Wolf, J; Bonchuk, I; Nilsen, M
2015-06-01
The International Commission on Radiological Protection (ICRP) recently reinforced the international system of radiological protection, initially focused on humans, by identifying principles of environmental protection and proposing a framework for assessing impacts of ionising radiation on non-human species, based on a reference flora and fauna approach. For this purpose, ICRP developed dosimetric models for a set of Reference Animals and Plants, which are representative of flora and fauna in different environments (terrestrial, freshwater, marine), and produced criteria based on information on radiation effects, with the aim of evaluating the level of potential or actual radiological impacts, and as an input for decision making. The approach developed by ICRP for flora and fauna is consistent with the approach used to protect humans. The International Atomic Energy Agency (IAEA) includes considerations on the protection of the environment in its safety standards, and is currently developing guidelines to assess radiological impacts based on the aforementioned ICRP approach. This paper presents the method developed by IAEA, in a series of meetings with international experts, to enable assessment of the radiological impact to the marine environment in connection with the Convention on the Prevention of Marine Pollution by Dumping of Wastes and Other Matter 1972 (London Convention 1972). This method is based on IAEA's safety standards and ICRP's recommendations, and was presented in 2013 for consideration by representatives of the contracting parties of the London Convention 1972; it was approved for inclusion in its procedures, and is in the process of being incorporated into guidelines. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Do we need a national incident reporting system for medical imaging?
Itri, Jason N; Krishnaraj, Arun
2012-05-01
The essential role of an incident reporting system as a tool to improve safety and reliability has been described in high-risk industries such as aviation and nuclear power, with anesthesia being the first medical specialty to successfully integrate incident reporting into a comprehensive quality improvement strategy. Establishing an incident reporting system for medical imaging that effectively captures system errors and drives improvement in the delivery of imaging services is a key component of developing and evaluating national quality improvement initiatives in radiology. Such a national incident reporting system would be most effective if implemented as one piece of a comprehensive quality improvement strategy designed to enhance knowledge about safety, identify and learn from errors, raise standards and expectations for improvement, and create safer systems through implementation of safe practices. The potential benefits of a national incident reporting system for medical imaging include reduced morbidity and mortality, improved patient and referring physician satisfaction, reduced health care expenses and medical liability costs, and improved radiologist satisfaction. The purposes of this article are to highlight the positive impact of external reporting systems, discuss how similar advancements in quality and safety can be achieved with an incident reporting system for medical imaging in the United States, and describe current efforts within the imaging community toward achieving this goal. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Jalilvand, Aryan; Fleming, Margaret; Moreno, Courtney; MacFarlane, Dan; Duszak, Richard
2018-01-01
The 2015 conversion of the International Classification of Diseases (ICD) system from the ninth revision (ICD-9) to the 10th revision (ICD-10) was widely projected to adversely impact physician practices. We aimed to assess code conversion impact factor (CCIF) projections and revenue delay impact to help radiology groups better prepare for eventual conversion to ICD, 11th revision (ICD-11). Studying 673,600 claims for 179 radiologists for the first year after ICD-10's implementation, we identified primary ICD-10 codes for the top 90th percentile of all examinations for the entire enterprise and each subspecialty division. Using established methodology, we calculated CCIFs (actual ICD-10 codes ÷ prior ICD-9 codes). To assess ICD-10's impact on cash flow, average monthly days in accounts receivable status was compared for the 12 months before and after conversion. Of all 69,823 ICD-10 codes, only 7,075 were used to report primary diagnoses across the entire practice, and just 562 were used to report 90% of all claims, compared with 348 under ICD-9. This translates to an overall CCIF of 1.6 for the department (far less than the literature-predicted 6). By subspecialty division, CCIFs ranged from 0.7 (breast) to 3.5 (musculoskeletal). Monthly average days in accounts receivable for the 12 months before and after ICD-10 conversion did not increase. The operational impact of the ICD-10 transition on radiology practices appears far less than anticipated with respect to both CCIF and delays in cash flow. Predictive models should be refined to help practices better prepare for ICD-11. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Lysdahl, Kristin B; Hofmann, Bjørn M
2009-01-01
Background Growth in use and overuse of diagnostic imaging significantly impacts the quality and costs of health care services. What are the modifiable factors for increasing and unnecessary use of radiological services? Various factors have been indentified, but little is known about their relative impact. Radiologists hold key positions for providing such knowledge. Therefore the purpose of this study was to obtain radiologists' perspective on the causes of increasing and unnecessary use of radiological investigations. Methods In a mailed questionnaire radiologist members of the Norwegian Medical Association were asked to rate potential causes of increased investigation volume (fifteen items) and unnecessary investigations (six items), using five-point-scales. Responses were analysed by using summary statistics and Factor Analysis. Associations between variables were determined using Students' t-test, Spearman rank correlation and Chi-Square tests. Results The response rate was 70% (374/537). The highest rated causes of increasing use of radiological investigations were: a) new radiological technology, b) peoples' demands, c) clinicians' intolerance for uncertainty, d) expanded clinical indications, and e) availability. 'Over-investigation' and 'insufficient referral information' were reported the most frequent causes of unnecessary investigations. Correlations between causes of increasing and unnecessary radiology use were identified. Conclusion In order to manage the growth in radiological imaging and curtail inappropriate investigations, the study findings point to measures that influence the supply and demand of services, specifically to support the decision-making process of physicians. PMID:19723302
Decompressive craniectomy and CSF disorders in children.
Manfiotto, Marie; Mottolese, Carmine; Szathmari, Alexandru; Beuriat, Pierre-Aurelien; Klein, Olivier; Vinchon, Matthieu; Gimbert, Edouard; Roujeau, Thomas; Scavarda, Didier; Zerah, Michel; Di Rocco, Federico
2017-10-01
Decompressive craniectomy (DC) is a lifesaving procedure but is associated to several post-operative complications, namely cerebrospinal fluid (CSF) dynamics impairment. The aim of this multicentric study was to evaluate the incidence of such CSF alterations after DC and review their impact on the overall outcome. We performed a retrospective multicentric study to analyze the CSF disorders occurring in children aged from 0 to 17 years who had undergone a DC for traumatic brain injury (TBI) in the major Departments of Pediatric Neurosurgery of France between January 2006 and August 2016. Out of 150 children, ranging in age between 7 months and 17 years, mean 10.75 years, who underwent a DC for TBI in 10 French pediatric neurosurgical centers. Sixteen (6 males, 10 females) (10.67%) developed CSF disorders following the surgical procedure and required an extrathecal CSF shunting. External ventricular drainage increased the risk of further complications, especially cranioplasty infection (p = 0.008). CSF disorders affect a minority of children after DC for TBI. They may develop early after the DC but they may develop several months after the cranioplasty (8 months), consequently indicating the necessity of clinical and radiological close follow-up after discharge from the neurosurgical unit. External ventricular drainage and permanent CSF shunt placement increase significantly the risk of cranioplasty infection.
Rosenkrantz, Andrew B; Ayoola, Abimbola; Singh, Kush; Duszak, Richard
2017-07-01
Emerging alternative metrics leverage social media and other online platforms to provide immediate measures of biomedical articles' reach among diverse public audiences. We aimed to compare traditional citation and alternative impact metrics for articles in popular general radiology journals. All 892 original investigations published in 2013 issues of Academic Radiology, American Journal of Roentgenology, Journal of the American College of Radiology, and Radiology were included. Each article's content was classified as imaging vs nonimaging. Traditional journal citations to articles were obtained from Web of Science. Each article's Altmetric Attention Score (Altmetric), representing weighted mentions across a variety of online platforms, was obtained from Altmetric.com. Statistical assessment included the McNemar test, the Mann-Whitney test, and the Pearson correlation. Mean and median traditional citation counts were 10.7 ± 15.4 and 5 vs 3.3 ± 13.3 and 0 for Altmetric. Among all articles, 96.4% had ≥1 traditional citation vs 41.8% for Altmetric (P < 0.001). Online platforms for which at least 5% of the articles were represented included Mendeley (42.8%), Twitter (34.2%), Facebook (10.7%), and news outlets (8.4%). Citations and Altmetric were weakly correlated (r = 0.20), with only a 25.0% overlap in terms of articles within their top 10th percentiles. Traditional citations were higher for articles with imaging vs nonimaging content (11.5 ± 16.2 vs 6.9 ± 9.8, P < 0.001), but Altmetric scores were higher in articles with nonimaging content (5.1 ± 11.1 vs 2.8 ± 13.7, P = 0.006). Although overall online attention to radiology journal content was low, alternative metrics exhibited unique trends, particularly for nonclinical articles, and may provide a complementary measure of radiology research impact compared to traditional citation counts. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Enzmann, Dieter R
2012-04-01
A diagnostic radiology value chain is constructed to define its main components, all of which are vulnerable to change, because digitization has caused disaggregation of the chain. Some components afford opportunities to improve productivity, some add value, while some face outsourcing to lower labor cost and to information technology substitutes, raising commoditization risks. Digital image information, because it can be competitive at smaller economies of scale, allows faster, differential rates of technological innovation of components, initiating a centralization-to-decentralization technology trend. Digitization, having triggered disaggregation of radiology's professional service model, may soon usher in an information business model. This means moving from a mind-set of "reading images" to an orientation of creating and organizing information for greater accuracy, faster speed, and lower cost in medical decision making. Information businesses view value chain investments differently than do small professional services. In the former model, producing a better business product will extend image interpretation beyond a radiologist's personal fund of knowledge to encompass expanding external imaging databases. A follow-on expansion with integration of image and molecular information into a report will offer new value in medical decision making. Improved interpretation plus new integration will enrich and diversify radiology's key service products, the report and consultation. A more robust, information-rich report derived from a "systems" and "computational" radiology approach will be facilitated by a transition from a professional service to an information business. Under health care reform, radiology will transition its emphasis from volume to greater value. Radiology's future brightens with the adoption of a philosophy of offering information rather than "reads" for decision making. Staunchly defending the status quo via turf wars is unlikely to constitute a forward-looking, competitive strategy. © RSNA, 2012.
Investigation of disorders of the anorectum and colon.
Henry, M. M.; Snooks, S. J.; Barnes, P. R.; Swash, M.
1985-01-01
Previously, investigation of disorders of the anorectum and colon have been limited to manometric, external anal sphincter muscle electromyographic and contrast radiological techniques. In this paper we describe other investigative techniques recently developed at St. Mark's Hospital, London and their application in the investigation of certain disorders of the anorectum and colon. Images Fig. 3 PMID:3878123
Teleradiology in Singapore--taking stock and looking ahead.
Cheng, Lionel T E; Ng, Samuel E S
2006-08-01
Teleradiology will have a significant impact on the delivery of healthcare and the practice of medicine. In order to ensure a positive outcome, the expected benefits, limitations and potential pitfalls of teleradiology must be carefully considered. For Singapore, teleradiology can be used to facilitate a quantum leap in the standards of radiological services. This can be achieved through the development of an integrated, nationwide, high-speed radiology network which will allow patients to have access to high-quality and responsive subspecialty radiology expertise located throughout the country. If judiciously implemented, teleradiology has the potential to propel Singapore radiology to an unprecedented level of professional quality and service delivery, and will provide the framework for sustainable radiological insourcing from other countries.
Patel, Samir
2015-03-01
Health care is in a state of transition, shifting from volume-based success to value-based success. Hospital executives and referring physicians often do not understand the total value a radiology group provides. A template for easy, cost-effective implementation in clinical practice for most radiology groups to demonstrate the value they provide to their clients (patients, physicians, health care executives) has not been well described. A value management program was developed to document all of the value-added activities performed by on-site radiologists, quantify them in terms of time spent on each activity (investment), and present the benefits to internal and external stakeholders (outcomes). The radiology value-added matrix is the platform from which value-added activities are categorized and synthesized into a template for defining investments and outcomes. The value management program was first implemented systemwide in 2013. Across all serviced locations, 9,931.75 hours were invested. An annual executive summary report template demonstrating outcomes is given to clients. The mean and median individual value-added hours per radiologist were 134.52 and 113.33, respectively. If this program were extrapolated to the entire field of radiology, approximately 30,000 radiologists, this would have resulted in 10,641,161 uncompensated value-added hours documented in 2013, with an estimated economic value of $2.21 billion. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Li, Feng
2015-07-01
This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruuge, A; Erdi, Y; Mahmood, U
Purpose: The conformance of Primary Diagnostic Monitors (PDMs) to the DICOM GSDF is increasingly required by several state and city regulators. Our purpose was to quantitatively characterize the luminance performance of the internal, built in photometer of BARCO monitors against an externally calibrated luminance meter. Methods: Thirty one PDMs (BARCO) were included in our analysis. An externally calibrated photometer (RaySafe Solo Light) was used to measure the luminance and illuminance values. Measured monitors were located at various hospital sites, radiology physicians’ offices and radiology reading rooms. All measured PDMs were equipped with the manufacturer’s built-in photometers and connected to Barcomore » MediCal QA web service for manual and automatic quality control measurements. PDM combinations included 1, 2 and 4 monitors depending on the location. TG-18 and SMPTE test patterns were used to evaluate monitor performance. Results: All the PDMs exceeded the luminance ratio of 250:1, as required by NYC PDM guidelines. One PDM failed the NYC requirement for the minimal luminance level of 350 cd/m2. As compared to the external photometer, the difference in measurement of the maximum luminance with the built-in photometer was found to exceed 5% on 6 of the PDM measured, with a maximum deviation of 10%. The age of the monitors that failed was on average 5 years. All monitors passed the luminance uniformity test, which was 30% from the center of the monitor to the 4 corner locations. Four PDMs failed the Gray Scale Display Function (GSDF) calibration. Conclusion: For the consistent display of medical images and continued conformance with the DICOM GSDF standard, it is essential to compare the performance of the built-in photometer with an externally calibrated photometer for monitors that are older than 5 years.« less
Assessment of medical occupational radiation doses in Costa Rica.
Mora, P; Acuña, M
2011-09-01
Participation of the University of Costa Rica (UCR) in activities in an IAEA Regional Project RLA/9/066 through training, equipment and expert missions, has enabled to setting up of a national personal monitoring laboratory. Since 2007, the UCR has been in charge of monitoring around 1800 medical radiation workers of the Social Security System. Individual external doses are measured with thermoluminescent dosemeter using a Harshaw 6600 Plus reader. The service has accreditation with ISO/IEC 17025:2005. Distribution of monitored medical personnel is as follows: 83 % in diagnostic radiology, 6 % in nuclear medicine and 6 % in radiotherapy. Preliminary values for the 75 percentile of annual H(p)(10) in mSv are: radiology 0.37; interventional radiology 0.41; radiotherapy 0.53 and nuclear medicine 1.55. The service provided by the UCR in a steady and reliable way can help to implement actions to limit the doses received by the medical workers and optimise their radiation protection programs.
Radiological dispersion devices: are we prepared?
Sohier, Alain; Hardeman, Frank
2006-01-01
Already before the events of September 11th 2001 concern was raised about the spread of orphan sources and their potential use in Radiological Dispersion Devices by terrorist groups. Although most of the simulated scenarios foresee a rather limited direct health impact on the population, the affected region would suffer from the indirect consequences such as social disruption, cleanup requirements and economic costs. The nature of such a radiological attack would anyway be different compared to conventional radiological accidents, basically because it can happen anywhere at any time. Part of the response resides in a general preparedness scheme incorporating attacks with Radiological Dispersion Devices. Training of different potential intervention teams is essential. The response would consist of a prioritised list of actions adapted to the circumstances. As the psychosocial dimension of the crisis could be worse than the purely radiological one, an adapted communication strategy with the public aspect would be a key issue.
Itri, Jason N; Lawson, Leslie M
2016-07-01
Radiology leaders can have a profound impact on the success and working environment of a radiology department, promoting core values and inspiring staff members to achieve the organization's mission. On the other hand, ineffective leaders can have a devastating effect on a radiology department by impairing communication among members, undermining staff commitment to the organization's success, and stifling the development of other staff members and leaders in the organization. One of the most important investments a radiology department can make is in identifying, cultivating, and promoting new leaders. The authors describe 13 habits and characteristics of new leaders that lead these individuals to address situations in both ineffective and counterproductive ways, impeding the performance of a radiology department and its capacity to play a meaningful role in shaping the future of radiology. New leaders must continually learn and improve their leadership skills if they are to avoid the destructive habits of ineffective leaders and successfully overcome the challenges facing radiology today. Senior leaders may also benefit from understanding the pitfalls that make leaders ineffective and should strive to continually improve their leadership skills given the critical role of leadership in the success of radiology departments. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
García-Talavera, M; Matarranz, J L M; Salas, R; Ramos, L
2011-01-01
Radioactive and chemical risks coexist in NORM industries although they are usually addressed separately by regulations. The European Union (EU) has developed extensive legislation concerning both matters, which has been diversely reflected in national policies. We consider the case of the Spanish phosphate industry and analyse to which extent regulatory mandates have reduced the historical and ongoing radiological impact on the environment of phosphate facilities. Although no specific radiological constraints on effluent monitoring and release or on waste disposal have yet been imposed on NORM industries in Spain, other environmental regulations have achieved a substantial reduction on the phosphate industry impact. Nevertheless, a more efficient control could be established by eliminating the current conceptual and practical separation of chemical and radioactive risks in NORM industries. We highlight research needs to accomplish so and propose shorter-term measures that require active cooperation among the regulatory bodies involved. Copyright © 2010. Published by Elsevier Ltd.
Health Aspects of a Nuclear or Radiological Attack
2010-07-01
treatment capabilities, population monitoring, decontamination, and so on. The requirements should be developed by a process that engages stakeholders...IND or reactor accident would release radioiodine that could result in hypothyroidism or late thyroid nodules or cancer. External contamination... Treatment and Long-Term Monitoring Victims of acute radiation-related events will require prompt diagnosis and treatment of emergency medical and
Periosteal ganglion: a cause of cortical bone erosion.
McCarthy, E F; Matz, S; Steiner, G C; Dorfman, H D
1983-01-01
Three cases of periosteal ganglia of long bones are presented. These lesions are produced by mucoid degeneration and cyst formation of the periosteum to produce external cortical erosion and reactive periosteal new bone. They are not associated with a soft tissue ganglion or an intraosseous lesion. They may radiologically mimic other periosteal lesions or soft tissue neoplasms which erode bone.
Mucoceles of the sphenoid sinus.
Weaver, R G; Gates, G A
1979-01-01
Mucoceles of the sphenoid sinuses are uncommon; 60 cases have been reported in the world literature to date. Signs and symptoms are caused by local expansion of the mucocele and include headache (the most common symptom), ocular field deficits, external ophthalmoplegia (particularly the sixth cranial nerve), and proptosis. Radiologic correlation in the form of plain films and polytomorgraphy is the most reliable guide in the diagnosis of sphenoid sinus disease. Therapy of these lesions is surgical, and drainage can be achieved via the external ethmoid or sublabial transseptal route. Three cases are presented: two had classical findings and the third was conspicuous by the presence of aseptic meningitis in the absence of local findings.
49 CFR 520.25 - External review of draft environmental impact statements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 6 2010-10-01 2010-10-01 false External review of draft environmental impact... ENVIRONMENTAL IMPACTS Procedures § 520.25 External review of draft environmental impact statements. (a... by law or special expertise with respect to the possible environmental impact involved, and from the...
49 CFR 520.25 - External review of draft environmental impact statements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 6 2014-10-01 2014-10-01 false External review of draft environmental impact... ENVIRONMENTAL IMPACTS Procedures § 520.25 External review of draft environmental impact statements. (a... by law or special expertise with respect to the possible environmental impact involved, and from the...
49 CFR 520.25 - External review of draft environmental impact statements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 6 2011-10-01 2011-10-01 false External review of draft environmental impact... ENVIRONMENTAL IMPACTS Procedures § 520.25 External review of draft environmental impact statements. (a... by law or special expertise with respect to the possible environmental impact involved, and from the...
49 CFR 520.25 - External review of draft environmental impact statements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 6 2012-10-01 2012-10-01 false External review of draft environmental impact... ENVIRONMENTAL IMPACTS Procedures § 520.25 External review of draft environmental impact statements. (a... by law or special expertise with respect to the possible environmental impact involved, and from the...
49 CFR 520.25 - External review of draft environmental impact statements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 6 2013-10-01 2013-10-01 false External review of draft environmental impact... ENVIRONMENTAL IMPACTS Procedures § 520.25 External review of draft environmental impact statements. (a... by law or special expertise with respect to the possible environmental impact involved, and from the...
2014-01-01
Hemodynamically Unstable Pelvic Trauma is a major problem in blunt traumatic injury. No cosensus has been reached in literature on the optimal treatment of this condition. We present the results of the First Italian Consensus Conference on Pelvic Trauma which took place in Bergamo on April 13 2013. An extensive review of the literature has been undertaken by the Organizing Committee (OC) and forwarded to the Scientific Committee (SC) and the Panel (JP). Members of them were appointed by surgery, critical care, radiology, emergency medicine and orthopedics Italian and International societies: the Italian Society of Surgery, the Italian Association of Hospital Surgeons, the Multi-specialist Italian Society of Young Surgeons, the Italian Society of Emergency Surgery and Trauma, the Italian Society of Anesthesia, Analgesia, Resuscitation and Intensive Care, the Italian Society of Orthopaedics and Traumatology, the Italian Society of Emergency Medicine, the Italian Society of Medical Radiology, Section of Vascular and Interventional Radiology and the World Society of Emergency Surgery. From November 2012 to January 2013 the SC undertook the critical revision and prepared the presentation to the audience and the Panel on the day of the Conference. Then 3 recommendations were presented according to the 3 submitted questions. The Panel voted the recommendations after discussion and amendments with the audience. Later on a email debate took place until December 2013 to reach a unanimous consent. We present results on the 3 following questions: which hemodynamically unstable patient needs an extraperitoneal pelvic packing? Which hemodynamically unstable patient needs an external fixation? Which hemodynamically unstable patient needs emergent angiography? No longer angiography is considered the first therapeutic maneuver in such a patient. Preperitoneal pelvic packing and external fixation, preceded by pelvic binder have a pivotal role in the management of these patients. Hemodynamically Unstable Pelvic Trauma is a frequent death cause among people who sustain blunt trauma. We present the results of the First Italian Consensus Conference. PMID:24606950
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perez-Sanchez, Danyl
As a result of a pilot project developed at the old Spanish 'Junta de Energia Nuclear' to extract uranium from ores, tailings materials were generated. Most of these residual materials were sent back to different uranium mines, but a small amount of it was mixed with conventional building materials and deposited near the old plant until the surrounding ground was flattened. The affected land is included in an area under institutional control and used as recreational area. At the time of processing, uranium isotopes were separated but other radionuclides of the uranium decay series as Th-230, Ra-226 and daughters remainmore » in the residue. Recently, the analyses of samples taken at different ground's depths confirmed their presence. This paper presents the methodology used to calculate the derived concentration level to ensure that the reference dose level of 0.1 mSv y-1 used as radiological criteria. In this study, a radiological impact assessment was performed modeling the area as recreational scenario. The modelization study was carried out with the code RESRAD considering as exposure pathways, external irradiation, inadvertent ingestion of soil, inhalation of resuspended particles, and inhalation of radon (Rn-222). As result was concluded that, if the concentration of Ra-226 in the first 15 cm of soil is lower than, 0.34 Bq g{sup -1}, the dose would not exceed the reference dose. Applying this value as a derived concentration level and comparing with the results of measurements on the ground, some areas with a concentration of activity slightly higher than latter were found. In these zones the remediation proposal has been to cover with a layer of 15 cm of clean material. This action represents a reduction of 85% of the dose and ensures compliance with the reference dose. (authors)« less
Patients' experience of outsourcing and care related to magnetic resonance examinations.
Tavakol Olofsson, Parvin; Aspelin, Peter; Bergstrand, Lott; Blomqvist, Lennart
2014-11-01
Outsourcing radiological examinations from public university hospitals affects the patient, who has to attend a different clinic or hospital for the radiological examination. We currently have a limited understanding of how patients view outsourcing and their care related to MR examinations. To examine the experiences of patients who are sent to private radiology units when their referrals for MR examinations are outsourced from a university hospital, as well as to explore factors which influence patient satisfaction regarding the quality of care related to the MR examination. A group of patients (n = 160) referred for MR examinations and either examined at a university hospital or at an external private unit were interviewed. The interview was designed as a verbal questionnaire. Data were analyzed using Student's t test, analysis of variance (ANOVA), and Pearson's correlation. Sixty-nine percent of the patients could neither choose nor influence the location at which they were examined. For those who could, aspects that influenced the patient's choice of radiology department were: short waiting time 79% (127/160), ease of traveling to the radiology department 68% (110/160), and short distance to their home or work 58% (93/160). For 40% (60/160) of the patients, a short time in the waiting room was related to a positive experience of the MR examination. If patients were informed about outsourcing and could also choose where to have their examination, key factors contributing to patient satisfaction could be met even when MR examinations are outsourced.
In the Lead Again Horizontal-Ellipsis [Journal of Cardiovascular and Interventional Radiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de
The 2013 ISI journal rankings are out and it is my pleasure to inform our readership that CVIR ranks 43/120 (2012: 46/118) journals in the field of radiology. The 2013 impact factor further improved to 2.138 (2012: 2.093). This means that Cardiovascular and Interventional Radiology again continues to be the highest ranked journal dedicated to the field of interventional radiology in 2013.This is mainly due to the great support we achieve by you as authors and readers of CVIR, your dedication to the profession, and your loyalty both to the journal and to CIRSE. For all of this, we owemore » you our thanks and respect.« less
An In-Depth Study on the Impact of External Quality Assurance
ERIC Educational Resources Information Center
Stensaker, Bjorn; Langfeldt, Liv; Harvey, Lee; Huisman, Jeroen; Westerheijden, Don
2011-01-01
After more than two decades of external quality assurance, there is an increasing interest in questions concerning the impact and effects of this activity. Following an external evaluation of NOKUT--the Norwegian quality assurance agency, this article studies the impact of external quality assurance in detail by analysing quantitative and…
Active pixel as dosimetric device for interventional radiology
NASA Astrophysics Data System (ADS)
Servoli, L.; Baldaccini, F.; Biasini, M.; Checcucci, B.; Chiocchini, S.; Cicioni, R.; Conti, E.; Di Lorenzo, R.; Dipilato, A. C.; Esposito, A.; Fanó, L.; Paolucci, M.; Passeri, D.; Pentiricci, A.; Placidi, P.
2013-08-01
Interventional Radiology (IR) is a subspecialty of radiology comprehensive of all minimally invasive diagnostic and therapeutic procedures performed using radiological devices to obtain image guidance. The interventional procedures are potentially harmful for interventional radiologists and medical staff due to the X-ray diffusion by the patient's body. The characteristic energy range of the diffused photons spans few tens of keV. In this work we will present a proposal for a new X-ray sensing element in the energy range of interest for IR procedures. The sensing element will then be assembled in a dosimeter prototype, capable of real-time measurement, packaged in a small form-factor, with wireless communication and no external power supply to be used for individual operators dosimetry for IR procedures. For the sensor, which is the heart of the system, we considered three different Active Pixel Sensors (APS). They have shown a good capability as single X-ray photon detectors, up to several tens keV photon energy. Two dosimetric quantities have been considered, the number of detected photons and the measured energy deposition. Both observables have a linear dependence with the dose, as measured by commercial dosimeters. The uncertainties in the measurement are dominated by statistic and can be pushed at ˜5% for all the sensors under test.
Trends in radiology and experimental research.
Sardanelli, Francesco
2017-01-01
European Radiology Experimental , the new journal launched by the European Society of Radiology, is placed in the context of three general and seven radiology-specific trends. After describing the impact of population aging, personalized/precision medicine, and information technology development, the article considers the following trends: the tension between subspecialties and the unity of the discipline; attention to patient safety; the challenge of reproducibility for quantitative imaging; standardized and structured reporting; search for higher levels of evidence in radiology (from diagnostic performance to patient outcome); the increasing relevance of interventional radiology; and continuous technological evolution. The new journal will publish not only studies on phantoms, cells, or animal models but also those describing development steps of imaging biomarkers or those exploring secondary end-points of large clinical trials. Moreover, consideration will be given to studies regarding: computer modelling and computer aided detection and diagnosis; contrast materials, tracers, and theranostics; advanced image analysis; optical, molecular, hybrid and fusion imaging; radiomics and radiogenomics; three-dimensional printing, information technology, image reconstruction and post-processing, big data analysis, teleradiology, clinical decision support systems; radiobiology; radioprotection; and physics in radiology. The journal aims to establish a forum for basic science, computer and information technology, radiology, and other medical subspecialties.
Halpenny, Darragh; Burke, John; McNeill, Graeme; Snow, Aisling; Torreggiani, William C
2010-06-01
The aim of this study was to examine the geographic origin of publications in the highest impacting radiology journals and to examine the link between the percentage of gross domestic product (GDP) spent on research by a country and the output of radiology publications. The five highest impacting general radiology journals (according to the ISI Web of Knowledge database) were selected over a 6-year period from January 2002 to December 2007. Publications were totaled according to the country of the corresponding author. Publications (total and corrected for population size) were assessed according to the GDP of a given country and the percentage of GDP spent on research in that country. Correlation was determined using Spearman's rank. In total, 10,925 papers were identified. The top 10 nations produced 83.9% of the total number of papers. The United States was the most prolific country, with 41.7% of the total. The second-ranked and third-ranked countries were Germany (11.6%) and Japan (6.7%). Corrected for GDP, smaller European countries outperformed larger nations. Switzerland (0.925 publications per billion of GDP), Austria (0.694 publications per billion of GDP), and Belgium (0.648 publications per billion of GDP) produced the most papers per billion of GDP. When corrected for percentage of GDP spent on research, European countries again ranked highest, with Greece, Turkey, and Belgium having the best ratios. The percentage of GDP spent on research was positively correlated with the number of publications in high-ranking radiology journals (r = 0.603, P < .001). The United States is the most productive country in absolute number of publications. The flaws of using population size to compare publication output are clear, and a comparison using GDP and the percentage of GDP spent on research may give more meaningful results. When GDP is taken into consideration, smaller European countries are more productive. The importance of investment in radiologic research is emphasized by the association between increased funding of research and the number of publications in high-impacting radiology journals. Copyright (c) 2010 AUR. Published by Elsevier Inc. All rights reserved.
Quantitative evaluation of Iranian radiology papers and its comparison with selected countries.
Ghafoori, Mahyar; Emami, Hasan; Sedaghat, Abdolrasoul; Ghiasi, Mohammad; Shakiba, Madjid; Alavi, Manijeh
2014-01-01
Recent technological developments in medicine, including modern radiology have promoted the impact of scientific researches on social life. The scientific outputs such as article and patents are products that show the scientists' attempt to access these achievements. In the current study, we evaluate the current situation of Iranian scientists in the field of radiology and compare it with the selected countries in terms of scientific papers. For this purpose, we used scientometric tools to quantitatively assess the scientific papers in the field of radiology. Radiology papers were evaluated in the context of medical field audit using retrospective model. We used the related databases of biomedical sciences for extraction of articles related to radiology. In the next step, the situation of radiology scientific products of the country were determined with respect to the under study regional countries. Results of the current study showed a ratio of 0.19% for Iranian papers in PubMed database published in 2009. In addition, in 2009, Iranian papers constituted 0.29% of the Scopus scientific database. The proportion of Iranian papers in the understudy region was 7.6%. To diminish the gap between Iranian scientific radiology papers and other competitor countries in the region and achievement of document 2025 goals, multifold effort of the society of radiology is necessary.
The history and future of accelerator radiological protection.
Thomas, R H
2001-01-01
The development of accelerator radiological protection from the mid-1930s, just after the invention of the cyclotron, to the present day is described. Three major themes--physics, personalities and politics--are developed. In the sections describing physics the development of shielding design though measurement, radiation transport calculations, the impact of accelerators on the environment and dosimetry in accelerator radiation fields are described. The discussion is limited to high-energy, high-intensity electron and proton accelerators. The impact of notable personalities on the development of both the basic science and on the accelerator health physics profession itself is described. The important role played by scholars and teachers is discussed. In the final section. which discusses the future of accelerator radiological protection, some emphasis is given to the social and political aspects that must he faced in the years ahead.
The long-term problems of contaminated land: Sources, impacts and countermeasures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baes, C.F. III
1986-11-01
This report examines the various sources of radiological land contamination; its extent; its impacts on man, agriculture, and the environment; countermeasures for mitigating exposures; radiological standards; alternatives for achieving land decontamination and cleanup; and possible alternatives for utilizing the land. The major potential sources of extensive long-term land contamination with radionuclides, in order of decreasing extent, are nuclear war, detonation of a single nuclear weapon (e.g., a terrorist act), serious reactor accidents, and nonfission nuclear weapons accidents that disperse the nuclear fuels (termed ''broken arrows'').
Development of a rapidly deployed Department of Energy emergency response element.
Tighe, R J; Riland, C A; Hopkins, R C
2000-02-01
The Federal Radiological Emergency Response Plan (FRERP) directs the Department of Energy (DOE) to maintain a viable, timely, and fully documented response option capable of supporting the responsible Lead Federal Agency in the event of a radiological emergency impacting any state or United States territory (e.g., CONUS). In addition, the DOE maintains a response option to support radiological emergencies outside the continental United States (OCONUS). While the OCONUS mission is not governed by the FRERP, this response is operationally similar to that assigned to the DOE by the FRERP The DOE is prepared to alert, activate, and deploy radiological response teams to augment the Radiological Assistance Program and/or local responders. The Radiological Monitoring and Assessment Center (RMAC) is a phased response that integrates with the Federal Radiological Monitoring and Assessment Center (FRMAC) in CONUS environments and represents a stand-alone DOE response for OCONUS environments. The FRMAC/RMAC Phase I was formally "stood up" as an operational element in April 1999. The FRMAC/RMAC Phase II proposed "stand-up" date is midyear 2000.
Visscher, Kari L; Faden, Lisa; Nassrallah, Georges; Speer, Stacey; Wiseman, Daniele
2017-08-01
This article is a continuation of a qualitative study designed to explore how radiology exposures can impact medical student opinions and perceptions of radiology and radiologists. We focused on: 1) conducting a radiology exposure inventory from the perspective of the medical student; 2) student evaluation of the quality of the radiology exposures and suggestions for positive change; and 3) development of a framework to address the needs of medical students as it relates to radiology education in the undergraduate medical curriculum. Research methodology and design for this qualitative study were described in detail in a previous article by Visscher et al [1]. Participants included 28 medical students; 18 were in medical school years 1 and 2 (preclerkship), and 10 were in years 3 and 4 (clerkship). Specific to the focus of this article, the data revealed 3 major findings: 1) multiple exposures to radiology exist, and they are received and valued differently depending on the medical student's stage of professional development; 2) medical students value radiology education and want their radiology exposure to be comprehensive and high quality; 3) Medical students have constructive suggestions for improving the quality of both formal and informal radiology exposures. Performing a radiology exposure inventory from a medical student perspective is a useful way to explore how students receive and value radiology instruction. Medical students want a more comprehensive radiology education that can be summarized using the 5 C's of Radiology Education framework. The 5 C's (curriculum, coaching, collaborating, career and commitment) reflect medical students' desires to learn content that will support them in clinical practice, be supported in their professional development, and have the necessary information to make informed career decisions. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
A Comprehensive Analysis of Authorship in Radiology Journals.
Dang, Wilfred; McInnes, Matthew D F; Kielar, Ania Z; Hong, Jiho
2015-01-01
The purpose of our study was to investigate authorship trends in radiology journals, and whether International Committee of Medical Journal Editors (ICMJE) recommendations have had an impact on these trends. A secondary objective was to explore other variables associated with authorship trends. A retrospective, bibliometric analysis of 49 clinical radiology journals published from 1946-2013 was conducted. The following data was exported from MEDLINE (1946 to May 2014) for each article: authors' full name, year of publication, primary author institution information, language of publication and publication type. Microsoft Excel Visual Basics for Applications scripts were programmed to categorize extracted data. Statistical analysis was performed to determine the overall mean number of authors per article over time, impact of ICMJE guidelines, authorship frequency per journal, country of origin, article type and language of publication. 216,271 articles from 1946-2013 were included. A univariate analysis of the mean authorship frequency per year of all articles yielded a linear relationship between time and authorship frequency. The mean number of authors per article in 1946 (1.42) was found to have increased consistently by 0.07 authors/ article per year (R² = 0.9728, P<0.001) to 5.79 authors/article in 2013. ICMJE guideline dissemination did not have an impact on this rise in authorship frequency. There was considerable variability in mean authors per article and change over time between journals, country of origin, language of publication and article type. Overall authorship for 49 radiology journals across 68 years has increased markedly with no demonstrated impact from ICMJE guidelines. A higher number of authors per article was seen in articles from: higher impact journals, European and Asian countries, original research type, and those journals who explicitly endorse the ICMJE guidelines.
A Comprehensive Analysis of Authorship in Radiology Journals
Dang, Wilfred; McInnes, Matthew D. F.; Kielar, Ania Z.; Hong, Jiho
2015-01-01
Objectives The purpose of our study was to investigate authorship trends in radiology journals, and whether International Committee of Medical Journal Editors (ICMJE) recommendations have had an impact on these trends. A secondary objective was to explore other variables associated with authorship trends. Methods A retrospective, bibliometric analysis of 49 clinical radiology journals published from 1946–2013 was conducted. The following data was exported from MEDLINE (1946 to May 2014) for each article: authors’ full name, year of publication, primary author institution information, language of publication and publication type. Microsoft Excel Visual Basics for Applications scripts were programmed to categorize extracted data. Statistical analysis was performed to determine the overall mean number of authors per article over time, impact of ICMJE guidelines, authorship frequency per journal, country of origin, article type and language of publication. Results 216,271 articles from 1946–2013 were included. A univariate analysis of the mean authorship frequency per year of all articles yielded a linear relationship between time and authorship frequency. The mean number of authors per article in 1946 (1.42) was found to have increased consistently by 0.07 authors/ article per year (R² = 0.9728, P<0.001) to 5.79 authors/article in 2013. ICMJE guideline dissemination did not have an impact on this rise in authorship frequency. There was considerable variability in mean authors per article and change over time between journals, country of origin, language of publication and article type. Conclusion Overall authorship for 49 radiology journals across 68 years has increased markedly with no demonstrated impact from ICMJE guidelines. A higher number of authors per article was seen in articles from: higher impact journals, European and Asian countries, original research type, and those journals who explicitly endorse the ICMJE guidelines. PMID:26407072
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santucci, P.; Guetat, P.
1993-12-31
This document describes the code CERISE, Code d`Evaluations Radiologiques Individuelles pour des Situations en Enterprise et dans l`Environnement. This code has been developed in the frame of European studies to establish acceptance criteria of very low-level radioactive waste and materials. This code is written in Fortran and runs on PC. It calculates doses received by the different pathways: external exposure, ingestion, inhalation and skin contamination. Twenty basic scenarios are already elaborated, which have been determined from previous studies. Calculations establish the relation between surface, specific and/or total activities, and doses. Results can be expressed as doses for an average activitymore » unit, or as average activity limits for a set of reference doses (defined for each scenario analyzed). In this last case, the minimal activity values and the corresponding limiting scenarios, are selected and summarized in a final table.« less
Citation classics in radiology journals: the 100 top-cited articles, 1945-2012.
Yoon, Dae Young; Yun, Eun Joo; Ku, You Jin; Baek, Sora; Lim, Kyoung Ja; Seo, Young Lan; Yie, Miyeon
2013-09-01
The number of citations an article receives after its publication reflects its impact in the scientific community. The aim of this study was to identify and characterize the 100 top-cited articles published in radiology journals. The top-cited articles published in 12 radiology journals were identified using the database of Science Citation Index Expanded (1945-2012). The 100 top-cited articles were selected and analyzed with regard to the number of citations, year of publication, publishing journal, authorship, institution and country of origin, type of article, radiologic subspecialty, main topic, and radiologic technique. The 100 top-cited articles were published in eight radiology journals, led by Radiology (n=67) and followed by the American Journal of Roentgenology (n=11). These articles were published between 1939 and 2006 with a mean of 664.3 citations per article (range, 371-6931). Seventy-eight articles were published after 1979, 57 originated from the United States, and 69 were original articles. The most common subspecialties of study were interventional radiology (n=19), neuroradiology (n=15), and breast imaging (n=11). The main topics of articles were radiofrequency ablation of hepatic tumors (n=9), followed by receiver operating characteristic curves (n=6). Our study presents a detailed list and analysis of the 100 top-cited articles published in radiology journals, which provides insight into historical developments in the field of radiology.
The Impact of Time on Decorporation Efficacy After a "Dirty Bomb" Attack Studied by Simulation.
Rump, A; Stricklin, D; Lamkowski, A; Eder, S; Abend, M; Port, M
2016-11-01
Background: In the case of a nuclear or radiological incident, there is a risk of external and internal contamination with radionuclides in addition to external irradiation. There is no consensus whether decorporation treatment should be initiated right away on spec or pending the results of internal dosimetry to determine the indication. Method: Based on biokinetic models for plutonium-239, americium-241 and cesium-137, the efficacy of a decorporation treatment using DTPA or Prussian blue was simulated depending on the initiation time and the duration of treatment for different invasion pathways and physicochemical properties of the inhaled compounds. Results: For the same level of radioactivity incorporated, the committed effective dose increases with the speed of the invasion process. The impact of the initiation time of a decorporation treatment is particularly important when the absorption of the radionuclide is fast. Even if started early after incorporation, the therapeutic efficacy is less for americium-241 or cesium-137 compared to plutonium-239. Therapeutic efficacy increases with treatment duration up to about 90 days for plutonium-239 and cesium-137, whereas a prolongation of the treatment over this limit may further enhance efficacy in the case of americium-241. Conclusion: In the case of a nuclear incident, several fractions with different but a priori unknown physicochemical properties may be inhaled. Thus, decorporation therapy should be started as soon as possible after the incorporation of the radionuclide(s), as a loss of efficacy caused by a delay of treatment initiation possibly cannot be compensated later on. Treatment should be pursued for several months. © Georg Thieme Verlag KG Stuttgart · New York.
Hanford Site near-facility environmental monitoring annual report, calendar year 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perkins, C.J.
1998-07-28
Near-facility environmental monitoring provides a means to measure the impacts of operations, waste management, and remediation activities on the environment adjacent to facilities and ensure compliance with local, state, and federal environmental regulations. Specifically, near-facility environmental monitoring monitors new and existing sites, processes, and facilities for potential impacts and releases; fugitive emissions and diffuse sources associated with contaminated areas, facilities (both active and those undergoing surveillance and maintenance), and environmental restoration activities. External radiation, ambient air particulates, ground and surface water, soil, sediment, and biota (plants and animals) are sampled or monitored. Parameters include, as appropriate, radionuclides; radiation fields; chemicalmore » or physical constituents, such as nitrates; pH; and water temperature. All ambient air results were below the US Department of Energy (DOE) Derived Concentration Guides (DCGs). Groundwater concentrations at the two wells at the 107-N Facility were below both the DOE DCG and US Environmental Protection Agency Interim Drinking Water Standards for gamma emitting radionuclides. Soil and vegetation results were generally within historic ranges and mostly below the Accessible Soil Concentration limits (included in HNF-PRO-454, Inactive Waste Sites) with the exception of one soil sampling location at 1 00 N Area. External radiation fields continued an overall downward trend. Surface water disposal unit samples (water, sediment, and aquatic vegetation) showed radionuclide concentrations below their respective DCG and Accessible Soil Concentration limits. The 100 N Area Columbia river shoreline springs results were below DCGs with the exception of one Sr concentration. More than 4,600 ha (11,300 acres) of radiologically controlled areas were surveyed in 1997, approximately the same as in 1996.« less
Web-based radiology: a future to be created.
Canadè, Adolfo; Palladino, Francesco; Pitzalis, Gianluca; Campioni, Paolo; Marano, Pasquale
2003-01-01
The impact of Internet on Medicine and Surgery is certainly remarkable, however the influence it had on Diagnostic Imaging was even stronger. The standardization of digital images acquired by the different medical imaging equipment has further facilitated the diffusion, transmission and communication in radiology within hospitals as well as on WEB. Radiology departments are bound to become "filmless" and with the present "tablet PC" radiological images will be directly transferred to the patient's bed in the relative electronic patient report. For radiology, interactive education could be envisaged with a tutor who guides the student(s) through the network. The Internet is an inexhaustible source of radiologic educational and information material with a number of sites of clinical cases, tutorial and teaching files, journals and magisterial lectures on-line. In a near future, the Internet could be applied in the simulation of clinicoradiologic cases or in applications of artificial intelligence with expert systems to support the solution of most complex cases.
Dense plasma focus (DPF) accelerated non radio isotopic radiological source
Rusnak, Brian; Tang, Vincent
2017-01-31
A non-radio-isotopic radiological source using a dense plasma focus (DPF) to produce an intense z-pinch plasma from a gas, such as helium, and which accelerates charged particles, such as generated from the gas or injected from an external source, into a target positioned along an acceleration axis and of a type known to emit ionizing radiation when impinged by the type of accelerated charged particles. In a preferred embodiment, helium gas is used to produce a DPF-accelerated He2+ ion beam to a beryllium target, to produce neutron emission having a similar energy spectrum as a radio-isotopic AmBe neutron source. Furthermore, multiple DPFs may be stacked to provide staged acceleration of charged particles for enhancing energy, tunability, and control of the source.
RCT: Module 2.04, Dosimetry, Course 8769
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hillmer, Kurt T.
This course will introduce the types of instruments used to measure external and internal radiation to people. Dosimetry is the quantitative assessment of radiation received by the human body. Several types of dosimeters are used worldwide. This information is valuable to all radiological control personnel because dosimeters are the only direct method to measure and document personnel radiation exposure and ensure regulatory compliance with applicable limits. This course will cover dosimetry terms, Department of Energy (DOE) limits, Los Alamos National Laboratory (LANL) administrative guidelines, thermoluminescent dosimeters (TLDs), LANL dosimetry, and bioassay assessment methods. This course will prepare the student withmore » the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and providing in-thefield skills.« less
Visentin, Sindi; Bevilacqua, Greta; Giraudo, Chiara; Dengo, Caterina; Nalesso, Alessandro; Montisci, Massimo
2017-11-01
Death due to mechanical or chemical intoxication of heroin body packers, thanks to the continuous improvement in packaging techniques, are increasingly rare, and almost all the cases reported in the literature refer to drug swallowers. A case of fatal acute heroin intoxication in a body pusher with an unreported packaging technique is presented, and previous deaths due to heroin body packing are reviewed, taking into consideration imaging techniques performed, cause of death, toxicological analysis on biological and non-biological samples, as well as number, position and type of drug packages identified at the dissection of the body. The innovative packaging technique found in the present case, constituted by an external multilayer cellophane casing containing 16 smaller packages of hardened heroin powder, each one covered with cigarette paper and multiple layers of heat-sealed cellophane, was probably used to avoid both chemical complications of package rupture and to create a package with morphological and radiological features different from those reported by previous studies. Drug dealers, in fact, are continually looking for packaging methods that, besides being safer, minimize the risk of detection at the radiological examinations performed, thus increasing the number of false negative findings. The identification of new types of package is therefore important, in order to identify packages that do not have the typical radiological signs, both in order to protect the patient's health and to avoid the non-recognition of a drug carrier. Despite the presence of multilayer composition of both the smaller and the bigger external coverage, these new types of package did not guarantee the greater safety of the drug dealer. Copyright © 2017 Elsevier B.V. All rights reserved.
Koontz, Nicholas A; Hill, Danielle V; Dodson, Sean C; Capps, Alisha E; Kamer, Aaron P; Frank, Mark S; Heitkamp, Darel E
2018-06-01
We report the development of a new "Case of the Day" (COTD) educational initiative using email, social media (SoMe), and a website to disseminate content, as well as its trends in viewership and assessment of utility for the first year of implementation. Using an image-rich format, a new unknown case was disseminated to radiology trainees and attendings at our institution by email twice per week, including history, salient images, and follow-up questions. Simultaneously, content was externally disseminated on Twitter and a publicly viewable departmental website. On subsequent days, the answer was posted via email, Twitter, and website in the form of a brief YouTube video lecture. Viewership data were collected over the first 12 months (July 1, 2016 to June 30, 2017), and an anonymous survey of participants was performed. Sixty-five COTDs had complete viewership data and were included in our analysis, yielding 4911 "case" email views (mean = 76), 3798 "answer" email views (mean = 58), 68,034 "case" Twitter impressions (mean = 1047), 75,724 "answer" Twitter impressions (mean = 1164), 5465 "case" Twitter engagements (mean = 84), and 5307 "answer" Twitter engagements (mean = 82). COTD YouTube video lectures garnered 3657 views (mean = 61) amounting to 10,358 minutes of total viewing time. Viewers were very satisfied with COTD quality, with 97% (n = 63) reporting the quality as "good" or "excellent." Email and SoMe can serve as effective tools for disseminating radiology educational content. SoMe offers substantial external visibility and branding potential for programs. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Generalized “Satisfaction of Search”: Adverse Influences on Dual-Target Search Accuracy
Fleck, Mathias S.; Samei, Ehsan; Mitroff, Stephen R.
2013-01-01
The successful detection of a target in a radiological search can reduce the detectability of a second target, a phenomenon termed satisfaction of search (SOS). Given the potential consequences, here we investigate the generality of SOS with the goal of simultaneously informing radiology, cognitive psychology, and nonmedical searches such as airport luggage screening. Ten experiments utilizing nonmedical searches and untrained searchers suggest that SOS is affected by a diverse array of factors, including (1) the relative frequency of different target types, (2) external pressures (reward and time), and (3) expectations about the number of targets present. Collectively, these experiments indicate that SOS arises when searchers have a biased expectation about the low likelihood of specific targets or events, and when they are under pressure to perform efficiently. This first demonstration of SOS outside of radiology implicates a general heuristic applicable to many kinds of searches. In an example like airport luggage screening, the current data suggest that the detection of an easy-to-spot target (e.g., a water bottle) might reduce detection of a hard-to-spot target (e.g., a box cutter). PMID:20350044
NASA Astrophysics Data System (ADS)
Price, R. A.; Benson, C.; Joyce, M. J.; Rodgers, K.
2004-08-01
We present the details of a new linear array dosimeter consisting of a chain of semiconductors mounted on an ultra-thin (50 /spl mu/m thick) flexible substrate and housed in an intracavitary catheter. The semiconductors, manufactured by NMRC Cork, have not been packaging and incorporate a passivation layer that allows them to be mounted on the substrate using flip-chip-bonding. This paper reports, for the first time, the construction of a multiple (ten) detector array suited to in vivo dosimetry in the rectum, esophagus and vagina during external beam radiotherapy, as well as being adaptable to in vivo dosimetry during brachytherapy and diagnostic radiology.
Collaborative filtering to improve navigation of large radiology knowledge resources.
Kahn, Charles E
2005-06-01
Collaborative filtering is a knowledge-discovery technique that can help guide readers to items of potential interest based on the experience of prior users. This study sought to determine the impact of collaborative filtering on navigation of a large, Web-based radiology knowledge resource. Collaborative filtering was applied to a collection of 1,168 radiology hypertext documents available via the Internet. An item-based collaborative filtering algorithm identified each document's six most closely related documents based on 248,304 page views in an 18-day period. Documents were amended to include links to their related documents, and use was analyzed over the next 5 days. The mean number of documents viewed per visit increased from 1.57 to 1.74 (P < 0.0001). Collaborative filtering can increase a radiology information resource's utilization and can improve its usefulness and ease of navigation. The technique holds promise for improving navigation of large Internet-based radiology knowledge resources.
Radioactive Waste Management Complex low-level waste radiological performance assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maheras, S.J.; Rood, A.S.; Magnuson, S.O.
This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsitemore » receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected.« less
DiPiro, Pamela J; Krajewski, Katherine M; Giardino, Angela A; Braschi-Amirfarzan, Marta; Ramaiya, Nikhil H
2017-01-01
The purpose of the article is to describe the various radiology consultation models in the Era of Precision Medicine. Since the inception of our specialty, radiologists have served as consultants to physicians of various disciplines. A variety of radiology consultation services have been described in the literature, including clinical decision support, patient-centric, subspecialty interpretation, and/or some combination of these. In oncology care in particular, case complexity often merits open dialogue with clinical providers. To explore the utility and impact of radiology consultation services in the academic setting, this article will further describe existing consultation models and the circumstances that precipitated their development. The hybrid model successful at our tertiary cancer center is discussed. In addition, the contributions of a consultant radiologist in breast cancer care are reviewed as the archetype of radiology consultation services provided to oncology practitioners.
NASA Astrophysics Data System (ADS)
Zhang, Guozhi; Liu, Qian; Zeng, Shaoqun; Luo, Qingming
2008-07-01
The voxel-based visible Chinese human (VCH) adult male phantom has offered a high-quality test bed for realistic Monte Carlo modeling in radiological dosimetry simulations. The phantom has been updated in recent effort by adding newly segmented organs, revising walled and smaller structures as well as recalibrating skeletal marrow distributions. The organ absorbed dose against external proton exposure was calculated at a voxel resolution of 2 × 2 × 2 mm3 using the MCNPX code for incident energies from 20 MeV to 10 GeV and for six idealized irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), left-lateral (LLAT), right-lateral (RLAT), rotational (ROT) and isotropic (ISO), respectively. The effective dose on the VCH phantom was derived in compliance with the evaluation scheme for the reference male proposed in the 2007 recommendations of the International Commission on Radiological Protection (ICRP). Algorithm transitions from the revised radiation and tissue weighting factors are accountable for approximately 90% and 10% of effective dose discrepancies in proton dosimetry, respectively. Results are tabulated in terms of fluence-to-dose conversion coefficients for practical use and are compared with data from other models available in the literature. Anatomical variations between various computational phantoms lead to dose discrepancies ranging from a negligible level to 100% or more at proton energies below 200 MeV, corresponding to the spatial geometric locations of individual organs within the body. Doses show better agreement at higher energies and the deviations are mostly within 20%, to which the organ volume and mass differences should be of primary responsibility. The impact of body size on dose distributions was assessed by dosimetry of a scaled-up VCH phantom that was resized in accordance with the height and total mass of the ICRP reference man. The organ dose decreases with the directionally uniform enlargement of voxels. Potential pathways to improve the VCH phantom have also been briefly addressed. This work pertains to VCH-based systematic multi-particle dose investigations and will contribute to comparative dosimetry studies of ICRP standardized voxel phantoms in the near future.
User questionnaire to evaluate the radiological workspace.
van Ooijen, Peter M A; Koesoema, Allya P; Oudkerk, Matthijs
2006-01-01
Over the past few years, an increase in digitalization of radiology departments can be seen, which has a large impact on the work of the radiologists. This impact is not only demonstrated by the increased use of digital images but also by changing demands on the whole reading environment. In this study, we evaluated the satisfaction of our radiologists with our digital Picture Archival and Communication System environment and their workspace. This evaluation was performed by distribution of a questionnaire consisting of a score sheet and some open questions to all radiologists and residents. Out of 25 questionnaires, 12 were adequately answered and returned. Results clearly showed that most problems were present in the area of reading room design and layout and comfort and ergonomics. Based on the results from this study, adaptations were made and the results were also used in the planning of the redesign of the entire department of radiology.
Nodular fasciitis of the external auditory canal in six Egyptian children.
Abdel-Aziz, Mosaad; Khattab, Hany; El-bosraty, Hussam; El-hoshy, Hassan; Hesham, Ahmed; Al-taweel, Hayam W
2008-05-01
Nodular fasciitis of external auditory canal may mimic a malignant tumor due to its progressive course, so it was the aim of this study to focus on a new etiology for aural masses to avoid unnecessary aggressive treatment. Retrospective study on six children presented with aural masses that were diagnosed pathologically to have nodular fasciitis. Presentation of the cases clinically, radiologically and pathologically was carried out. Surgical excision of the lesions was done through the external canal with follow up of the cases for 1 year. Recurrence was detected in two cases, one after 2 months and the other after 4 months. Re-excision was carried out without recurrence till the end of the follow up period. Proper diagnosis of this lesion is mandatory to avoid aggressive treatment (radical surgery and/or radiotherapy) as the disease has favorable prognosis with local excision.
Use of personal digital assistants in diagnostic radiology resident education.
Nishino, Mizuki; Busch, James M; Wei, Jesse; Barbaras, Larry; Yam, Chun-Shan; Hatabu, Hiroto
2004-10-01
Personal digital assistants (PDAs) are gaining widespread use in the medical community. We introduced a PDA-based mobile system that provides departmental and educational information with a seamless connection to the intranet. The objective of this study is to determine the impact a PDA has on educational resources (learning or data reference) brought to work and used at home by a radiology resident based on user surveys. Survey was performed on 32 radiology residents in our department before and 6 months after the release of the PDA-based system. We assessed the changes in (1) sources of learning at home and at work, and in (2) data reference. The second survey also evaluated the usefulness of each component of the system. After the release of the PDA-based mobile system, the use of "digital books and references" as data references and educational resources that were brought to work every day significantly increased (P = .016, P < .0001, respectively). "Traditional books and references" remained the "most useful source in learning radiology"; however, "digital books and references" increased as the residents' first choice from 0% to 16% within 6 months of introducing the package (P = .125). The introduction of a PDA-based system consisting of educational and departmental information had a statistically significant impact in increasing the use of digitized information in radiology resident education.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dinis, Maria de Lurdes; Fiuza, Antonio; Soeiro de Carvalho, Jose
2013-07-01
Certain materials used and produced in a wide range of non-nuclear industries contain enhanced activity concentrations of natural radionuclides. In particular, electricity production from coal is one of the major sources of increased human exposure to naturally occurring radioactive materials. A methodology was developed to assess the radiological impact due to natural radiation background. The developed research was applied to a specific case study, the Sines coal-fired power plant, located in the southwest coastline of Portugal. Gamma radiation measurements were carried out with two different instruments: a sodium iodide scintillation detector counter (SPP2 NF, Saphymo) and a gamma ray spectrometermore » with energy discrimination (Falcon 5000, Canberra). Two circular survey areas were defined within 20 km of the power plant. Forty relevant measurements points were established within the sampling area: 15 urban and 25 suburban locations. Additionally, ten more measurements points were defined, mostly at the 20-km area. The registered gamma radiation varies from 20 to 98.33 counts per seconds (c.p.s.) corresponding to an external gamma exposure rate variable between 87.70 and 431.19 nGy/h. The highest values were measured at locations near the power plant and those located in an area within the 6 and 20 km from the stacks. In situ gamma radiation measurements with energy discrimination identified natural emitting nuclides as well as their decay products (Pb-212, Pb-2142, Ra-226, Th-232, Ac-228, Th-234, Pa-234, U- 235, etc.). According to the results, an influence from the stacks emissions has been identified both qualitatively and quantitatively. The developed methodology accomplished the lack of data in what concerns to radiation rate in the vicinity of Sines coal-fired power plant and consequently the resulting exposure to the nearby population. (authors)« less
NASA Astrophysics Data System (ADS)
Caridi, F.; Messina, M.; Faggio, G.; Santangelo, S.; Messina, G.; Belmusto, G.
2018-02-01
The two most significant categories of physical and chemical pollutants in sediments (radionuclides and metals) were investigated in this article, in order to evaluate pollution levels in marine sediments from eight different selected sites of the Calabria region, south of Italy. In particular samples were analyzed to determine natural and anthropic radioactivity and metal concentrations, in order to assess any possible radiological hazard, the level of contamination and the possible anthropogenic impact in the investigated area. Activity concentrations of 226Ra, 232Th, 40K and 137Cs were measured by High Purity Germanium (HPGe) gamma spectrometry. The obtained results show that, for radium (in secular equilibrium with uranium), the specific activity ranges from ( 14 ± 1) Bq/kg dry weight (d.w.) to ( 54 ± 9) Bq/kg d.w.; for thorium, from ( 12 ± 1) Bq/kg d.w. to ( 83 ± 8) Bq/kg d.w.; for potassium, from ( 470 ± 20) Bq/kg d.w. to ( 1000 ± 70) Bq/kg d.w. and for cesium it is lower than the minimum detectable activity value. The absorbed gamma dose rate in air (D), the annual effective dose equivalent (AEDE) outdoor and the external hazard index ( H_ex) were calculated to evaluate any possible radiological risk, mainly due to the use of marine sediments for the beach nourishment. The results show low levels of radioactivity, thus discarding any significant radiological risk. Some metals (As, Cd, Cr tot, Hg, Ni, Pb, Cu, Zn, Mn and Fe), that could be released into the environment by both natural and anthropogenic sources, were investigated through inductively coupled plasma mass spectrometry (ICP-MS) measurements and compared with the limits set by the Italian Legislation, to assess any possible contamination. Experimental results show that they are much lower than the contamination threshold value, thus excluding their presence as pollutants. The degree of sediment contaminations were quantified using enrichment factor ( EF) and geoaccumulation index ( I geo) for some potential hazardous elements. Results show that EF and I geo values of As, Pb and Mn were the greatest among the studied metals. Data of this preliminary study could be helpful in the future to obtain background levels in marine sediments of the investigated region and to develop environmental regulatory frameworks.
Characterization of the Radiological Environment at J-Village during Operation Tomodachi
2013-02-01
individual as compared to those for the helicopter crew members (Appendix A). 3.2.2. Other Relevant Dosimetry Results Thermoluminescent dosimeter ( TLD ...internal monitoring results are available for 14 of these individuals. External dosimetry data (EPD and TLD ) showed that the maximum recorded dose for an...Washington, DC. http://www.NNSAResponseData.net. Accessed December 7. USAFCRD (U. S. Air Force Center for Radiation Dosimetry ), 2011. Electronic Pocket
Maritime Detection of Radiological/Nuclear Threats with Hybrid Imaging System
2014-01-01
localization system. Each subsystem is housed in a separate 20-ft refrigerated ISO container that provides humidity and temperature control, and...externally via laptop or remotely via wireless communication. A detailed description of each individual subsystem follows. A. Detection...LN2. Each dewar has a cryogenic solenoid valve and a temperature sensor on the exhaust to monitor when the dewar is full. The valves and sensors are
Pediatric interventional radiology workforce survey: 10-year follow-up.
Kaufman, Claire S; James, Charles A; Harned, Roger K; Connolly, Bairbre L; Roebuck, Derek J; Cahill, Anne M; Dubois, Josee; Morello, Frank P; Morgan, Robin K; Sidhu, Manrita K
2017-05-01
Pediatric interventional radiology is a distinct subspecialty differing from both pediatric diagnostic radiology and adult interventional radiology. We conducted a workforce survey in 2005 to evaluate the state of pediatric interventional radiology at that time. Since then there have been many advancements to the subspecialty, including the founding of the Society for Pediatric Interventional Radiology (SPIR). To evaluate the current state of the pediatric interventional radiology workforce and compare findings with those of the initial 2005 workforce survey. We sent a two-part survey electronically to members of SPIR, the Society for Pediatric Radiology (SPR), the Society of Chairmen of Radiology in Children's Hospitals (SCORCH) and the Society of Interventional Radiology (SIR). Part 1 focused on individual practitioners (n=177), while part 2 focused on group practices and was answered by a leader from each group (n=88). We examined descriptive statistics and, when possible, compared the results to the study from 2005. A total of 177 individuals replied (a 331% increase over the first study) and 88 pediatric interventional radiology (IR) service sites responded (a 131.6% increase). Pediatric IR has become a more clinically oriented specialty, with a statistically significant increase in services with admitting privileges, clinics and performance of daily rounds. Pediatric IR remains diverse in training and practice. Many challenges still exist, including anesthesia/hospital support, and the unknown impact of the new IR residency on pediatric IR training, although the workforce shortage has been somewhat alleviated, as demonstrated by the decreased mean call from 165 days/year to 67.2 days/year. Pediatric interventional radiology practitioners and services have grown significantly since 2005, although the profile of this small subspecialty has changed and some challenges remain.
Patients’ experience of outsourcing and care related to magnetic resonance examinations
Aspelin, Peter; Bergstrand, Lott; Blomqvist, Lennart
2014-01-01
Background Outsourcing radiological examinations from public university hospitals affects the patient, who has to attend a different clinic or hospital for the radiological examination. We currently have a limited understanding of how patients view outsourcing and their care related to MR examinations. Aim Aim. To examine the experiences of patients who are sent to private radiology units when their referrals for MR examinations are outsourced from a university hospital, as well as to explore factors which influence patient satisfaction regarding the quality of care related to the MR examination. Methods A group of patients (n = 160) referred for MR examinations and either examined at a university hospital or at an external private unit were interviewed. The interview was designed as a verbal questionnaire. Data were analyzed using Student’s t test, analysis of variance (ANOVA), and Pearson’s correlation. Results Sixty-nine percent of the patients could neither choose nor influence the location at which they were examined. For those who could, aspects that influenced the patient’s choice of radiology department were: short waiting time 79% (127/160), ease of traveling to the radiology department 68% (110/160), and short distance to their home or work 58% (93/160). For 40% (60/160) of the patients, a short time in the waiting room was related to a positive experience of the MR examination. Conclusion Conclusion. If patients were informed about outsourcing and could also choose where to have their examination, key factors contributing to patient satisfaction could be met even when MR examinations are outsourced. PMID:25142133
Experimental Approaches to Assessing the Impact of a ...
Symposium Paper The US EPA, as part of the CRTI project team, is currently working to assess the impacts of an urban radiological dispersion device (RDD) and develop containment and decontamination strategies.
ERIC Educational Resources Information Center
Webb, Alexandra Louise; Choi, Sunhea
2014-01-01
A technology enhanced learning and teaching (TELT) solution, radiological anatomy (RA) eLearning, composed of a range of identification-based and guided learning activities related to normal and pathological X-ray images, was devised for the Year 1 nervous and locomotor course at the Faculty of Medicine, University of Southampton. Its…
Rosenkrantz, Andrew B; Lawson, Kirk; Ally, Rosina; Chen, David; Donno, Frank; Rittberg, Steven; Rodriguez, Joan; Recht, Michael P
2015-01-01
To evaluate sustainability of impact of rapid, focused process improvement (PI) events on process and performance within an academic radiology department. Our department conducted PI during 2011 and 2012 in CT, MRI, ultrasound, breast imaging, and research billing. PI entailed participation by all stakeholders, facilitation by the department chair, collection of baseline data, meetings during several weeks, definition of performance metrics, creation of an improvement plan, and prompt implementation. We explore common themes among PI events regarding initial impact and durability of changes. We also assess performance in each area pre-PI, immediately post-PI, and at the time of the current study. All PI events achieved an immediate improvement in performance metrics, often entailing both examination volumes and on-time performance. IT-based solutions, process standardization, and redefinition of staff responsibilities were often central in these changes, and participants consistently expressed improved internal leadership and problem-solving ability. Major environmental changes commonly occurred after PI, including a natural disaster with equipment loss, a change in location or services offered, and new enterprise-wide electronic medical record system incorporating new billing and radiology informatics systems, requiring flexibility in the PI implementation plan. Only one PI team conducted regular post-PI follow-up meetings. Sustained improvement was frequently, but not universally, observed: in the long-term following initial PI, measures of examination volume showed continued progressive improvements, whereas measures of operational efficiency remained stable or occasionally declined. Focused PI is generally effective in achieving performance improvement, although a changing environment influences the sustainability of impact. Thus, continued process evaluation and ongoing workflow modifications are warranted. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Ruiz, Emily Stamell; Karia, Pritesh S; Morgan, Frederick C; Schmults, Chrysalyne D
2017-02-01
There is limited evidence on the utility of radiologic imaging for prognostic staging of cutaneous squamous cell carcinoma (CSCC). Review utilization of radiologic imaging of high-stage CSCCs to evaluate whether imaging impacted management and outcomes. Tumors classified as Brigham and Women's Hospital (BWH) tumor (T) stage T2B or T3 over a 13-year period were reviewed to identify whether imaging was performed and whether results affected treatment. Disease-related outcomes (DRO: local recurrence, nodal metastasis, death from disease) were compared between patients by type of imaging used. 108 high-stage CSCCs in 98 patients were included. Imaging (mostly computed tomography, 79%) was utilized in 45 (46%) patients and management was altered in 16 (33%) patients who underwent imaging. Patients that received no imaging were at higher risk of developing nodal metastases (nonimaging, 30%; imaging, 13%; P = .041) and any DRO (nonimaging, 42%; imaging, 20%; P = .028) compared to the imaging group. Imaging was associated with a lower risk for DRO (subhazard ratio, 0.5; 95% CI 0.2-0.9; P = .046) adjusted for BWH T stage, sex, and location. Single institution retrospective design and changes in technology overtime. Radiologic imaging of high-stage CSCC may influence management and appears to positively impact outcomes. Further prospective studies are needed to establish which patients benefit from imaging. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.
Implementation of the integrated approach in different types of exposure scenarios.
Copplestone, D; Hirth, G; Johansen, M; Lazo, E; Takala, J; Sakai, K; Yankovich, T
2018-01-01
The International Commission on Radiological Protection (ICRP) recognises three types of exposure situations: planned, existing, and emergency. In all three situations, the release of radionuclides into the natural environment leads to exposures of non-human biota, as well as the potential for exposures of the public. This paper describes how the key principles of the ICRP system of radiological protection apply to non-human biota and members of the public in each of these exposure situations. Current work in this area within ICRP Task Group 105 is highlighted. For example, how simplified numeric criteria may be used in planned exposure situations that are protective of both the public and non-human biota. In emergency exposure situations, the initial response will always be focused on human protection; however, understanding the potential impacts of radionuclide releases on non-human biota will likely become important in terms of communication as governments and the public seek to understand the exposures that are occurring. For existing exposure situations, there is a need to better understand the potential impacts of radionuclides on animals and plants, especially when deciding on protective actions. Understanding the comparative impacts from radiological, non-radiological, and physical aspects is often important in managing the remediation of legacy sites. Task Group 105 is making use of case studies of how exposure situations have been managed in the past to provide additional guidance and advice for the protection of non-human biota.
Inpatient Complexity in Radiology-a Practical Application of the Case Mix Index Metric.
Mabotuwana, Thusitha; Hall, Christopher S; Flacke, Sebastian; Thomas, Shiby; Wald, Christoph
2017-06-01
With ongoing healthcare payment reforms in the USA, radiology is moving from its current state of a revenue generating department to a new reality of a cost-center. Under bundled payment methods, radiology does not get reimbursed for each and every inpatient procedure, but rather, the hospital gets reimbursed for the entire hospital stay under an applicable diagnosis-related group code. The hospital case mix index (CMI) metric, as defined by the Centers for Medicare and Medicaid Services, has a significant impact on how much hospitals get reimbursed for an inpatient stay. Oftentimes, patients with the highest disease acuity are treated in tertiary care radiology departments. Therefore, the average hospital CMI based on the entire inpatient population may not be adequate to determine department-level resource utilization, such as the number of technologists and nurses, as case length and staffing intensity gets quite high for sicker patients. In this study, we determine CMI for the overall radiology department in a tertiary care setting based on inpatients undergoing radiology procedures. Between April and September 2015, CMI for radiology was 1.93. With an average of 2.81, interventional neuroradiology had the highest CMI out of the ten radiology sections. CMI was consistently higher across seven of the radiology sections than the average hospital CMI of 1.81. Our results suggest that inpatients undergoing radiology procedures were on average more complex in this hospital setting during the time period considered. This finding is relevant for accurate calculation of labor analytics and other predictive resource utilization tools.
Collado-Mesa, Fernando; Alvarez, Edilberto; Arheart, Kris
2018-02-21
Advances in artificial intelligence applied to diagnostic radiology are predicted to have a major impact on this medical specialty. With the goal of establishing a baseline upon which to build educational activities on this topic, a survey was conducted among trainees and attending radiologists at a single residency program. An anonymous questionnaire was distributed. Comparisons of categorical data between groups (trainees and attending radiologists) were made using Pearson χ 2 analysis or an exact analysis when required. Comparisons were made using the Wilcoxon rank sum test when the data were not normally distributed. An α level of 0.05 was used. The overall response rate was 66% (69 of 104). Thirty-six percent of participants (n = 25) reported not having read a scientific medical article on the topic of artificial intelligence during the past 12 months. Twenty-nine percent of respondents (n = 12) reported using artificial intelligence tools during their daily work. Trainees were more likely to express doubts on whether they would have pursued diagnostic radiology as a career had they known of the potential impact artificial intelligence is predicted to have on the specialty (P = .0254) and were also more likely to plan to learn about the topic (P = .0401). Radiologists lack exposure to current scientific medical articles on artificial intelligence. Trainees are concerned by the implications artificial intelligence may have on their jobs and desire to learn about the topic. There is a need to develop educational resources to help radiologists assume an active role in guiding and facilitating the development and implementation of artificial intelligence tools in diagnostic radiology. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Entrepreneurial Women in Radiology: Role Models of Success.
Anzai, Yoshimi; Meltzer, Carolyn C; DeStigter, Kristen K; Destounis, Stamatia; Pawley, Barbara K; Oates, M Elizabeth
2016-11-01
Radiology is undeniably male dominated. Alongside surgery and orthopedic surgery, academic radiology ranks near the bottom in having the lowest proportion of full-time female faculty members. Despite many efforts to recruit talented women, the pipeline entering the radiologic disciplines continues to flow at a trickle. One factor is the relative lack of role models for female medical students. Entrepreneurial women in radiology can lead the field with their innovation and creativity, courage, and commitment. In this article, the authors highlight two entrepreneurial female radiologists who shared their success stories at the American Association for Women Radiologists' session at the 2015 ACR annual meeting. Their successes underscore the potential for such women to serve as role models to female medical students and even college undergraduates. Despite the gender gap in radiology, the field has yielded some exceptional women who can take on challenges, overcome barriers and assume risks, create strategies and processes to operationalize their visions, secure funding, and expand their enterprises to make sustainable impacts both at home and abroad. As we move toward more patient- and family-centered care models and become increasingly visible to diverse populations, there is no better time for female leaders in radiology to inspire the next generation to join our essential and rewarding specialty. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
The Radiology Resident iPad Toolbox: an educational and clinical tool for radiology residents.
Sharpe, Emerson E; Kendrick, Michael; Strickland, Colin; Dodd, Gerald D
2013-07-01
Tablet computing and mobile resources are the hot topics in technology today, with that interest spilling into the medical field. To improve resident education, a fully configured iPad, referred to as the "Radiology Resident iPad Toolbox," was created and implemented at the University of Colorado. The goal was to create a portable device with comprehensive educational, clinical, and communication tools that would contain all necessary resources for an entire 4-year radiology residency. The device was distributed to a total of 34 radiology residents (8 first-year residents, 8 second-year residents, 9 third-year residents, and 9 fourth-year residents). This article describes the process used to develop and deploy the device, provides a distillation of useful applications and resources decided upon after extensive evaluation, and assesses the impact this device had on resident education. The Radiology Resident iPad Toolbox is a cost-effective, portable, educational instrument that has increased studying efficiency; improved access to study materials such as books, radiology cases, lectures, and web-based resources; and increased interactivity in educational conferences and lectures through the use of audience-response software, with questions geared toward the new ABR board format. This preconfigured tablet fully embraces the technology shift into mobile computing and represents a paradigm shift in educational strategy. Copyright © 2013 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Jones, Alison; Jones, Kelly; Holmes, Sheila; Ewers, Leon; Cabianca, Tiberio
2013-03-01
The aim of this work is to assess the possible radiological impact on the population of the United Kingdom (UK) from new nuclear power stations proposed for up to eight sites in England and Wales. The radiological impact was measured in terms of collective dose to the UK, European and world populations from a single year's discharge integrated to 500 and 100 000 years and the annual dose to an average member of the UK population (known as the per-caput dose). The doses were calculated for two reactor types, UK EPR™ and AP1000™, using the annual expected discharges estimated by the designers of the reactors and assuming two reactors per site. In addition, typical individual doses to adults living close to the sites were calculated on the basis of continuous discharges for 60 years (the assumed lifetime of the reactors). The dose to a representative person (previously known as the critical group) was not calculated, as this has been done elsewhere. The assessments were carried out using the software program PC-CREAM 08(®) which implements the updated European Commission methodology for assessing the radiological impact of routine releases of radionuclides to the environment. The collective dose truncated to 500 years to the UK population was estimated to be 0.5 manSv assuming UK EPR reactors on all sites and 0.6 manSv assuming AP1000s on three sites with UK EPRs on the other sites. The most significant contribution to the collective dose to the UK population is due to the global circulation of carbon-14 released to the atmosphere. The annual dose to an average member of the UK population from all sites was calculated to be around 10 nSv y(-1) and would therefore contribute little to an individual's total radiation dose. All the calculated doses to a typical adult living near the sites assuming continuous discharges for 60 years were found to be below 1 μSv y(-1).
Investigation of the radiological impact on the coastal environment surrounding a fertilizer plant.
El Samad, O; Aoun, M; Nsouli, B; Khalaf, G; Hamze, M
2014-07-01
This investigation was carried out in order to assess the marine environmental radioactive pollution and the radiological impact caused by a large production plant of phosphate fertilizer, located in the Lebanese coastal zone. Natural radionuclides ((238)U, (235)U, (232)Th, (226)Ra, (210)Po, (210)Pb, (40)K) and anthropogenic (137)Cs were measured by alpha and gamma spectrometry in seawater, sediment, biota and coastal soil samples collected from the area impacted by this industry. The limited environmental monitoring program within 2 km of the plant indicates localized contamination with radionuclides of the uranium decay chain mainly due to the transport, the storage of raw materials and the free release of phosphogypsum waste. Copyright © 2013 Elsevier Ltd. All rights reserved.
Goel, Atul; Jain, Sonal; Shah, Abhidha
2018-02-01
To evaluate the musculoskeletal and soft tissue neural alterations in cases with group A basilar invagination. Between January 2007 and August 2016, 510 patients with group A basilar invagination were surgically treated. The radiologic images of these patients were reviewed retrospectively. The patients were divided into 4 groups: group A1, comprising 60 patients with syringomyelia; group A2, comprising 354 patients with "external syrinx," marked by excessive cerebrospinal fluid (CSF) in the extramedullary space; group A3, comprising 51 patients with both syringomyelia and external syrinx; and group A4, comprising 45 patients with no abnormality of CSF cavitation in the spinal canal. A number of musculoskeletal and neural parameters, including the extent of basilar invagination, degree of angulation of the odontoid process, and facet malalignment, were evaluated in each of the 4 groups. The degree of basilar invagination was 6-27.4 mm (average, 15.85 mm) in group A1, 4.3-24.5 mm (average, 12.56 mm) in group A2, 5.6-17.6 mm (average 10.8 mm) in group A3, and 5.2-17.3 mm (average, 11.74 mm) in group A4. The angle of inclination of the odontoid process was 61.1-90.7 degrees (average, 71.4 degrees) in group A1, 30.5-79.8 degrees (average, 60.05 degrees) in group A2, 68.5-78.3 degrees (average, 73.4 degrees) in group A3, and 62.2-87.4 degrees (average, 71.2 degrees) in group A4. The nature of bone malformations directly influences the presence or absence of external syrinx and syringomyelia. Copyright © 2017 Elsevier Inc. All rights reserved.
Zhivin, Sergey; Guseva Canu, Irina; Samson, Eric; Laurent, Olivier; Grellier, James; Collomb, Philippe; Zablotska, Lydia B; Laurier, Dominique
2016-03-01
Until recently, enrichment of uranium for civil and military purposes in France was carried out by gaseous diffusion using rapidly soluble uranium compounds. We analysed the relationship between exposure to soluble uranium compounds and exposure to external γ-radiation and mortality in a cohort of 4688 French uranium enrichment workers who were employed between 1964 and 2006. Data on individual annual exposure to radiological and non-radiological hazards were collected for workers of the AREVA NC, CEA and Eurodif uranium enrichment plants from job-exposure matrixes and external dosimetry records, differentiating between natural, enriched and depleted uranium. Cause-specific mortality was compared with the French general population via standardised mortality ratios (SMR), and was analysed via Poisson regression using log-linear and linear excess relative risk models. Over the period of follow-up, 131 161 person-years at risk were accrued and 21% of the subjects had died. A strong healthy worker effect was observed: all causes SMR=0.69, 95% CI 0.65 to 0.74. SMR for pleural cancer was significantly increased (2.3, 95% CI 1.06 to 4.4), but was only based on nine cases. Internal uranium and external γ-radiation exposures were not significantly associated with any cause of mortality. This is the first study of French uranium enrichment workers. Although limited in statistical power, further follow-up of this cohort, estimation of internal uranium doses and pooling with similar cohorts should elucidate potential risks associated with exposure to soluble uranium compounds. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
ASSESSMENT OF EYE LENS DOSES IN INTERVENTIONAL RADIOLOGY: A SIMULATION IN LABORATORY CONDITIONS.
Čemusová, Z; Ekendahl, D; Judas, L
2016-09-01
As workers in interventional radiology belong to one of the most occupationally exposed groups, methods for sufficiently accurate quantification of their external exposure are sought. The objective of the authors' experiment was to investigate the relations between eye lens dose and Hp(10), Hp(3) or Hp(0.07) values measured with a conventional whole-body personal thermoluminescence dosemeter (TLD). Conditions of occupational exposure during common interventional procedures were simulated in laboratory. An anthropomorphic phantom represented a physician. The TLDs were fixed to the phantom in different locations that are common for purposes of personal dosimetry. In order to monitor the dose at the eye lens level during the exposures, a special thermoluminescence eye dosemeter was fixed to the phantom's temple. Correlations between doses measured with the whole-body and the eye dosemeters were found. There are indications that personnel in interventional radiology do not need to be unconditionally equipped with additional eye dosemeters, especially if an appropriate whole-body dosimetry system has been already put into practice. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zainal, Fetri; Hamzah, Zaini; Wood, Khalik
2016-01-22
The accumulation of radionuclides in soil is a greatest concerns due to their toxicity. This study investigated the vertical distribution of radionuclides and radiological assessment in a soil profile were collected in three different directions [North (N), North-East (NE) and South-East (SE)] within 40 km from Manjung district. All profile samples were collected down to 45cm at 7.5cm interval using hand auger. Soil density and radionuclides ({sup 40}K, Th and U) concentrations were determined by gravimetric method and Energy Dispersive X-Ray Fluorescence (EDXRF) technique, respectively. The radionuclides concentrations was in decreasing order of {sup 40}K > Th > U. Soil qualitymore » assessment was carried out using Enrichment Factor (EF), Pollution Index (PI) and Geoaccumulation Index (I {sub geo}) where all radionuclides show significant enrichment (5 < EF < 20), PI classified as middle pollution classes and 0 < Igeo < 1, indicating moderately polluted, respectively. From the concentration of radionuclides, the radiological risk was calculated and the present result show external hazard index (H{sub ex}) is below than unity indicate low radiological risk.« less
Fonio, Paolo; Appendino, Elena; Calandri, Marco; Faletti, Riccardo; Righi, Dorico; Gandini, Giovanni
2015-02-01
The aim of this study is to evaluate the efficacy and safety of interventional radiology procedures in the treatment of major urological complications after kidney transplantation. Between 2000 and 2010, 1,146 kidney transplants were performed at our institution. A total of 146 major complications occurred, including 77 obstructions, 36 leaks and 33 associated perigraft fluid collections. Percutaneous treatment was carried out in 118/146 complications in 91 patients. In the case of stenosis-obstruction and fistulas (104 complications), the first therapeutic step was placement of a nephrostomy catheter, followed by balloon ureteroplasty, placement of external-internal catheters and double-J stents; 14/33 collections were drained under ultrasound guidance. In all 118 percutaneous interventions, we were able to place a nephrostomy or drainage catheter, with a technical success rate of 100 %. The long-term success rate was 49.6 %: in 57/115 (three patients were lost to follow-up) we obtained the complete resolution of the complication. The procedure-related mortality rate was 0 %. There was only one major complication and the rate of minor complications was 14.4 %. Interventional radiology is the first choice option in the treatment of urological complications after kidney transplantation.
Evaluation of paediatric radiology services in hospitals in the UK.
Halliday, K; Drinkwater, K; Howlett, D C
2016-12-01
To compare paediatric radiology provision across the UK with national standards published by the Department of Health and the Royal College of Radiologists (RCR). Audit standards and indicators for paediatric imaging were derived from "Delivering quality imaging services for children", 1 "Standards for imaging in cases of suspected non-accidental injury" 2 and "Improving paediatric interventional radiology services" 3 and agreed jointly by the Clinical Radiology Audit Committee and the British Society of Paediatric Radiology. A questionnaire was sent to all hospitals and NHS trusts imaging children aged 16 or younger in the UK in October 2013. The target for all indicators was 100%. Eighty-seven of 196 (44%) eligible institutions submitted data, the size distribution of the institutions was representative when compared to data from "Facing the future: a review of paediatric services" 4 published by the Royal College of Paediatrics and Child health. Only 65% of paediatric images were obtained by staff who had had specific training and only 60% were reported by radiographers or radiologists with appropriate training. Sixty-two percent of centres did not have access to a paediatric opinion 24 hours a day, 7 days a week all year; only 34% of radiographers who regularly imaged children had had any access to continuing professional development (CPD) in the 12 months of the audit. Although all hospitals had facilities for image transfer, only 57% had any formal funding arrangements in place for external reporting of images. The standards set for a network approach to paediatric radiology provision in "Delivering quality imaging services for children" are largely unmet. This failure to make the most of the workforce and resources puts vulnerable children at risk. The authors urge NHS England to work with the RCR to organise and administer a national network for paediatric imaging. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Radiation Safety System for SPIDER Neutral Beam Accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandri, S.; Poggi, C.; Coniglio, A.
2011-12-13
SPIDER (Source for Production of Ion of Deuterium Extracted from RF Plasma only) and MITICA (Megavolt ITER Injector Concept Advanced) are the ITER neutral beam injector (NBI) testing facilities of the PRIMA (Padova Research Injector Megavolt Accelerated) Center. Both injectors accelerate negative deuterium ions with a maximum energy of 1 MeV for MITICA and 100 keV for SPIDER with a maximum beam current of 40 A for both experiments. The SPIDER facility is classified in Italy as a particle accelerator. At present, the design of the radiation safety system for the facility has been completed and the relevant reports havemore » been presented to the Italian regulatory authorities. Before SPIDER can operate, approval must be obtained from the Italian Regulatory Authority Board (IRAB) following a detailed licensing process. In the present work, the main project information and criteria for the SPIDER injector source are reported together with the analysis of hypothetical accidental situations and safety issues considerations. Neutron and photon nuclear analysis is presented, along with special shielding solutions designed to meet Italian regulatory dose limits. The contribution of activated corrosion products (ACP) to external exposure of workers has also been assessed. Nuclear analysis indicates that the photon contribution to worker external exposure is negligible, and the neutron dose can be considered by far the main radiation protection issue. Our results confirm that the injector has no important radiological impact on the population living around the facility.« less
Prabhu, Vinay; Rosenkrantz, Andrew B
2015-07-01
The aim of this study was to evaluate use of the microblogging social network Twitter by academic radiology departments (ARDs) in the United States. Twitter was searched to identify all accounts corresponding with United States ARDs. All original tweets from identified accounts over a recent 3-month period (August to October 2014) were archived. Measures of account activity, as well as tweet and link content, were summarized. Fifteen ARDs (8.2%) had Twitter accounts. Ten (5.5%) had "active" accounts, with ≥1 tweet over the 3-month period. Active accounts averaged 711 ± 925 followers (maximum, 2,885) and 61 ± 93 tweets (maximum, 260) during the period. Among 612 tweets from active accounts, content most commonly related to radiology-related education (138), dissemination of departmental research (102), general departmental or hospital promotional material (62), departmental awards or accomplishments (60), upcoming departmental lectures (59), other hospital-related news (55), medical advice or information for patients (38), local community events or news (29), social media and medicine (27), and new departmental or hospital hires or expansion (19). Eighty percent of tweets (490 of 612) included 315 unique external links. Most frequent categories of link sources were picture-, video-, and music-sharing websites (89); the ARD's website or blog (83); peer-reviewed journal articles (40); the hospital's or university's website (34), the lay press (28), and Facebook (14). Twitter provides ARDs the opportunity to engage their own staff members, the radiology community, the department's hospital, and patients, through a broad array of content. ARDs frequently used Twitter for promotional and educational purposes. Because only a small fraction of ARDs actively use Twitter, more departments are encouraged to take advantage of this emerging communication tool. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Fienitz, Tim; Moses, Ofer; Klemm, Christoph; Happe, Arndt; Ferrari, Daniel; Kreppel, Matthias; Ormianer, Zeev; Gal, Moti; Rothamel, Daniel
2017-04-01
The objective of this study is to histologically and radiologically compare a sintered and a non-sintered bovine bone substitute material in sinus augmentation procedures. Thirty-three patients were included in the clinically controlled randomized multicentre study resulting in a total of 44 treated sinuses. After lateral approach, sinuses were filled with either a sintered (SBM, Alpha Bio's Graft ® ) or a non-sintered (NSBM, Bio Oss ® ) deproteinized bovine bone substitute material. The augmentation sites were radiologically assessed before and immediately after the augmentation procedure as well as prior to implant placement. Bone trephine biopsies for histological analysis were harvested 6 months after augmentation whilst preparing the osteotomies for implant placement. Healing was uneventful in all patients. After 6 months, radiological evaluation of 43 sinuses revealed a residual augmentation height of 94.65 % (±2.74) for SBM and 95.76 % (±2.15) for NSBM. One patient left the study for personal reasons. Histological analysis revealed a percentage of new bone of 29.71 % (±13.67) for SBM and 30.57 % (±16.07) for NSBM. Residual bone substitute material averaged at 40.68 % (±16.32) for SBM compared to 43.43 % (±19.07) for NSBM. All differences between the groups were not statistically significant (p > 0.05, Student's t test). Both xenogeneic bone substitute materials showed comparable results regarding new bone formation and radiological height changes in external sinus grafting procedures. Both bone substitute materials allow for a predictable new bone formation following sinus augmentation procedures.
Preparedness for radiological emergency situations in Austria.
Ditto, Manfred
2012-02-01
This article presents the Austrian system of emergency preparedness for nuclear and radiological emergency situations. It demonstrates, in particular, the legal basis, the roles and competencies of the competent authorities, international and bilateral conventions on early notification of nuclear accidents, the Austrian emergency plans, the Austrian radiation monitoring system, the operated prognosis and decision support systems and the results of an estimation of possible impacts of nuclear power plant disasters on Austria.
The geomagnetically trapped radiation environment: A radiological point of view
NASA Technical Reports Server (NTRS)
Holly, F. E.
1972-01-01
The regions of naturally occurring, geomagnetically trapped radiation are briefly reviewed in terms of physical parameters such as; particle types, fluxes, spectrums, and spatial distributions. The major emphasis is placed upon a description of this environment in terms of the radiobiologically relevant parameters of absorbed dose and dose-rate and a discussion of the radiological implications in terms of the possible impact on space vehicle design and mission planning.
Shaikh, Faiq; Hendrata, Kenneth; Kolowitz, Brian; Awan, Omer; Shrestha, Rasu; Deible, Christopher
2017-06-01
In the era of value-based healthcare, many aspects of medical care are being measured and assessed to improve quality and reduce costs. Radiology adds enormously to health care costs and is under pressure to adopt a more efficient system that incorporates essential metrics to assess its value and impact on outcomes. Most current systems tie radiologists' incentives and evaluations to RVU-based productivity metrics and peer-review-based quality metrics. In a new potential model, a radiologist's performance will have to increasingly depend on a number of parameters that define "value," beginning with peer review metrics that include referrer satisfaction and feedback from radiologists to the referring physician that evaluates the potency and validity of clinical information provided for a given study. These new dimensions of value measurement will directly impact the cascade of further medical management. We share our continued experience with this project that had two components: RESP (Referrer Evaluation System Pilot) and FRACI (Feedback from Radiologist Addressing Confounding Issues), which were introduced to the clinical radiology workflow in order to capture referrer-based and radiologist-based feedback on radiology reporting. We also share our insight into the principles of design thinking as applied in its planning and execution.
DISPOSITION PATHS FOR ROCKY FLATS GLOVEBOXES: EVALUATING OPTIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lobdell, D.; Geimer, R.; Larsen, P.
2003-02-27
The Kaiser-Hill Company, LLC has the responsibility for closure activities at the Rocky Flats Environmental Technology Site (RFETS). One of the challenges faced for closure is the disposition of radiologically contaminated gloveboxes. Evaluation of the disposition options for gloveboxes included a detailed analysis of available treatment capabilities, disposal facilities, and lifecycle costs. The Kaiser-Hill Company, LLC followed several processes in determining how the gloveboxes would be managed for disposition. Currently, multiple disposition paths have been chosen to accommodate the needs of the varying styles and conditions of the gloveboxes, meet the needs of the decommissioning team, and to best managemore » lifecycle costs. Several challenges associated with developing a disposition path that addresses both the radiological and RCRA concerns as well as offering the most cost-effective solution were encountered. These challenges included meeting the radiological waste acceptance criteria of available disposal facilities, making a RCRA determination, evaluating treatment options and costs, addressing void requirements associated with disposal, and identifying packaging and transportation options. The varying disposal facility requirements affected disposition choices. Facility conditions that impacted decisions included radiological and chemical waste acceptance criteria, physical requirements, and measurement for payment options. The facility requirements also impacted onsite activities including management strategies, decontamination activities, and life-cycle cost.« less
A national UK survey of radiology trainees special interest choices: what and why?
Parvizi, Nassim; Bhuva, Shaheel
2017-11-01
A national survey was designed to better understand factors influencing special interest choices, future aspirations of UK radiology trainees and perceptions of breast radiology. A SurveyMonkey questionnaire was developed and distributed to all radiology trainees in the UK through the British Institute of Radiology, RCR Junior Radiologists Forum and by directly contacting UK training schemes as well as by social media between December 2015 and January 2016. From 21 training schemes across the UK, 232 responses were received. Over half entered radiology after foundation training and 62% were ST1-3; one-fifth of trainees intended to leave the NHS. The most popular special interests were musculoskeletal (18%), abdominal imaging (16%) and neuroradiology (13%). Gynaecological and oncological imaging proved to be the least popular. Strong personal interest, a successful rotation during training, a mix of imaging modalities, direct impact on patient care and job prospects were the most popular factors influencing career choice. Research and potential for private income were the least influential factors. Respondents detailed their perceptions of breast radiology, selecting an awareness of career prospects (41%) and a better trainee experience (36%) as factors that would increase their interest in pursuing it as a career. Understanding the factors that influence special interest choice is essential to addressing the alarming staffing shortfalls that will befall certain radiology special interests. Addressing trainee's preconceptions and improving the trainee experience are key to attracting trainees to breast radiology. Advances in knowledge: This is the first survey of its kind in the UK literature designed to evaluate special interest career choices and the factors that influence those among radiology trainees.
The malpractice liability of radiology reports: minimizing the risk.
Srinivasa Babu, Aparna; Brooks, Michael L
2015-01-01
The art and science of interpreting radiologic examinations, an ability that is acquired over years of training, is on display in every radiology report. It is vital that these reports be crafted so as to both reflect the radiologist's expertise and capability and eliminate any factors that might result in unintended harm to the patient. Unfortunately, a deficient report may result in legal action against the radiologist; thus, a thorough understanding of the litigious potential of the language used in radiology reports is crucial. It is important that ambiguous vocabulary, undefined modifiers, double negatives, and generalizations be avoided. Errors in radiology reports may result from inappropriate terminology, transcription mistakes, or deficient or inadequately documented communication. Critical findings that may have an immediate impact on patient management must be promptly communicated to the referring physician and such communication fully documented. A meticulous and well-written report is the best way for radiologists to care for their patients. In addition, a well-worded report can be the deciding factor in a successful defense against a malpractice claim. Understanding the legal implications of radiology reports will enable radiologists to develop strategies for avoiding malpractice suits. (©)RSNA, 2015.
Educational Impact of Trainee-Facilitated Head and Neck Radiology-Pathology Correlation Conferences.
Ginat, Daniel Thomas; Cipriani, Nicole A; Christoforidis, Gregory
2018-05-17
The goal of this study was to evaluate the benefits of resident and fellow-facilitated radiology-pathology head and neck conferences. A total of seven resident-facilitated and six fellow-facilitated head and neck radiology-pathology cases were presented as part of the radiology department conference series. The radiology residents were surveyed regarding the perceived quality and effectiveness of the fellow-facilitated sessions. The number of publications yielded from all the cases presented was tracked. Overall, the residents assessed the quality of the fellow-facilitated conferences with an average score of 3.9 out of 5 and the overall helpfulness with an average of 3.5 out of 5. The overall average level of resident understanding among the residents for the topics presented to them by the fellows at baseline was 2.5 out of 5 and 3.4 out of 5 after the presentations, which was a significant increase (p-value < 0.01). There were three peer-reviewed publications generated from the resident presentations and four peer-reviewed publications generated from the fellow presentations, which represents a 54% publication rate collectively. Therefore, trainee-facilitated head and neck radiology-pathology conferences at our institution provide added learning and scholarly activity opportunities.
Does gender impact upon application rejection rate among Canadian radiology residency applicants?
Baerlocher, Mark O; Walker, Michelle
2005-10-01
To determine if and how gender ratios have changed within Canadian radiology, and to determine if gender discrimination occurs at the level of the radiology resident selection committee. The Canadian Medical Association, Canadian Association of Radiologists, Canadian Institute for Health Information, Royal College of Physicians and Surgeons of Canada, and Canadian Residency Matching Service provided gender-specific data. We compared the proportion of female applicants who ranked a radiology program as their top choice and were rejected from any radiology program with the corresponding proportion for male applicants. The numbers of women and men being awarded an MD from a Canadian university equalized nearly a decade ago. Women continue to be numerically underrepresented among practicing radiologists; however, the proportion of women continues to increase so that there is 1 female radiologist in practice to every 3 male radiologists in practice in 2005. More male medical students ranked a radiology residency training program as their top choice in the residency match; however, of those who did, they were as likely as women to be rejected from a radiology residency training program. Grouping all female and male graduating medical students participating in the residency match and ranking a radiology residency as their top choice between 1993 and 2004, the odds of men being rejected were 1.4 times (95% CI 0.99-1.9, p = 0.07) greater than for women. There continues to be more men than women radiologists in practice; however, the female-to-male ratio continues to increase. Our data suggest that discrimination against female applicants at the level of radiology residency selection does not occur.
Buikema, Kathryn E; Adams, Erin G
2012-01-01
Calcification or ossification of the auricle, also referred to as petrified ear, is a rare diagnosis in dermatology. In medical literature, it has most often been attributed to trauma, hypothermia and frostbite, or hypercalcemia secondary to a metabolic or endocrine disorder, such as Addison's disease. Here, we report the clinical and radiologic findings of a 79-year-old African American male whose unilateral petrified auricle was an incidental finding. He had a preceding history of hyperparathyroidism and subsequent hypercalcemia treated with a subtotal parathyroidectomy three years prior to presentation. In addition to laboratory analysis, a history and physical examination was performed which revealed no other signs of hypercalcemia. Radiologic studies demonstrated partial ossification of the external auricular cartilage on the left side. The patient was diagnosed with the rare occurrence of a petrified ear. In light of this case, we provide a discussion concerning the possible etiologies of this diagnosis including appropriate patient evaluation and possible treatment recommendations.
Buikema, Kathryn E.; Adams, Erin G.
2012-01-01
Calcification or ossification of the auricle, also referred to as petrified ear, is a rare diagnosis in dermatology. In medical literature, it has most often been attributed to trauma, hypothermia and frostbite, or hypercalcemia secondary to a metabolic or endocrine disorder, such as Addison's disease. Here, we report the clinical and radiologic findings of a 79-year-old African American male whose unilateral petrified auricle was an incidental finding. He had a preceding history of hyperparathyroidism and subsequent hypercalcemia treated with a subtotal parathyroidectomy three years prior to presentation. In addition to laboratory analysis, a history and physical examination was performed which revealed no other signs of hypercalcemia. Radiologic studies demonstrated partial ossification of the external auricular cartilage on the left side. The patient was diagnosed with the rare occurrence of a petrified ear. In light of this case, we provide a discussion concerning the possible etiologies of this diagnosis including appropriate patient evaluation and possible treatment recommendations. PMID:23259082
von Schewelov, T; Carlsson, A; Sanzén, L; Besjakov, J
2014-05-01
In 2005, we demonstrated that the polished triple-tapered C-stem at two years had migrated distally and rotated internally. From that series, 33 patients have now been followed radiologically, clinically and by radiostereometric analysis (RSA) for up to ten years. The distal migration within the cement mantle had continued and reached a mean of 2 mm (0.5 to 4.0) at ten years. Internal rotation, also within the cement mantle, was a mean 3.8° (external 1.6° to internal 6.6°) The cement mantle did not show any sign of migration or loosening in relation to the femoral bone. There were no clinical or radiological signs indicating that the migration or rotation within the cement mantle had had any adverse effects for the patients.
Abdominal hernias: Radiological features
Lassandro, Francesco; Iasiello, Francesca; Pizza, Nunzia Luisa; Valente, Tullio; Stefano, Maria Luisa Mangoni di Santo; Grassi, Roberto; Muto, Roberto
2011-01-01
Abdominal wall hernias are common diseases of the abdomen with a global incidence approximately 4%-5%. They are distinguished in external, diaphragmatic and internal hernias on the basis of their localisation. Groin hernias are the most common with a prevalence of 75%, followed by femoral (15%) and umbilical (8%). There is a higher prevalence in males (M:F, 8:1). Diagnosis is usually made on physical examination. However, clinical diagnosis may be difficult, especially in patients with obesity, pain or abdominal wall scarring. In these cases, abdominal imaging may be the first clue to the correct diagnosis and to confirm suspected complications. Different imaging modalities are used: conventional radiographs or barium studies, ultrasonography and Computed Tomography. Imaging modalities can aid in the differential diagnosis of palpable abdominal wall masses and can help to define hernial contents such as fatty tissue, bowel, other organs or fluid. This work focuses on the main radiological findings of abdominal herniations. PMID:21860678
CAD/CAM-produced surgical guides: Optimizing the treatment workflow.
Neugebauer, J; Kistler, F; Kistler, S; Züdorf, G; Freyer, D; Ritter, L; Dreiseidler, T; Kusch, J; Zöller, J E
2011-01-01
The increased availability of devices for 3D radiological diagnosis allows the more frequent use of CAD/CAM-produced surgical guides for implant placement. The conventional workflow requires a complex logistic chain which is time-consuming and costly. In a pilot study, the workflow of directly milled surgical guides was evaluated. These surgical guides were designed based on the fusion of an optical impression and the radiological data. The clinical use showed that the surgical guides could be accurately placed on the residual dentition without tipping movements. The conventional surgical guides were used as a control for the manual check of the deviation of the implant axis. The direct transfer of the digital planning data allows the fabrication of surgical guides in an external center without the need of physical transport, which reduces the logistic effort and expense of the central fabrication of surgical guides.
Studzinski, J
2017-06-01
The Digital Imaging Adoption Model (DIAM) has been jointly developed by HIMSS Analytics and the European Society of Radiology (ESR). It helps evaluate the maturity of IT-supported processes in medical imaging, particularly in radiology. This eight-stage maturity model drives your organisational, strategic and tactical alignment towards imaging-IT planning. The key audience for the model comprises hospitals with imaging centers, as well as external imaging centers that collaborate with hospitals. The assessment focuses on different dimensions relevant to digital imaging, such as software infrastructure and usage, workflow security, clinical documentation and decision support, data exchange and analytical capabilities. With its standardised approach, it enables regional, national and international benchmarking. All DIAM participants receive a structured report that can be used as a basis for presenting, e.g. budget planning and investment decisions at management level.
Shimura, Tsutomu; Yamaguchi, Ichiro; Terada, Hiroshi; Robert Svendsen, Erik; Kunugita, Naoki
2015-01-01
Herein we summarize the public health actions taken to mitigate exposure of the public to radiation after the Fukushima accident that occurred on 11 March 2011 in order to record valuable lessons learned for disaster preparedness. Evacuations from the radiation-affected areas and control of the distribution of various food products contributed to the reduction of external and internal radiation exposure resulting from the Fukushima incident. However, risk communication is also an important issue during the emergency response effort and subsequent phases of dealiing with a nuclear disaster. To assist with their healing process, sound, reliable scientific information should continue to be disseminated to the radiation-affected communities via two-way communication. We will describe the essential public health actions following a nuclear disaster for the early, intermediate and late phases that will be useful for radiological preparedness planning in response to other nuclear or radiological disasters. PMID:25862700
2014-01-01
Background The radiological quality of 226Ra, 232Th and 40K in some samples of water resources collected in Anarak-Khour a desertic area, Iran has been measured by direct gamma ray spectroscopy using high purity germanium detector in this paper. Result The concentration ranged from ≤0.5 to 9701 mBq/L for 226Ra; ≤0.2 to 28215 mBq/L for 232Th and < MDA to 10332 mBq/L for 40K. The radium equivalent activity was well below the defined limit of 370Bq/L. The calculated external hazard indices were found to be less than 1 which shows a low dose. Conclusion These results can be contributed to the database of this area because it may be used as disposal sites of nuclear waste in future. PMID:24883192
[Risk factors for teeth aplasia and hypoplasia in cleft lip and palate children].
Korolenkova, M V; Starikova, N V; Ageeva, L V
2016-01-01
The aim of the study was to assess the significance of environmental risk factors for teeth aplasia and hypoplasia in cleft lip and palate children. Two hundred and forty-seven cleft lip and palate (CLP) children were enrolled in the study including 105 (42.5%) with bilateral CLP and 57.5% with unilateral CLP. The mean age was 11.2±4.9 years. Teeth condition was assessed clinically and radiologically. The impact of risk factors for teeth anomalies was analyzed by retrospective data obtained from computer database (absence of preoperative orthopedic treatment, palatal defects after primary palatoplasty and type of primary procedures). Surgical trauma by early periosteoplasty (at the age of 3-4 months), excessive scarring and tissue traction due to absence of early orthopedic treatment and palatal defect were associated with significantly higher incidence of incisors hypoplasia (both developmental enamel defects and microdentia) and aplasia of central incisors not seen in the other study subgroups. Incisors aplasia and hypoplasia in CLP patients do not always have disembryogenic origin but may depend on external environmental factors, including surgical trauma.
Fatal lawn mower related projectile injury.
Colville-Ebeling, Bonnie; Lynnerup, Niels; Banner, Jytte
2014-06-01
Fatal lawn mower related injuries are a relatively rare occurrence. In a forensic setting, the primary aim is to reconstruct the injury mechanism and establish the cause of death. A relatively rare, but characteristic type of injury is a so-called projectile or missile injury. This occurs when the operator or a bystander is impacted by an object mobilized from the grass by the rotating mower blades. This type of injury often leaves only modest external trauma, which increases the risk of overlooking an entry wound. In this paper we present a case of a fatal lawn mower related projectile injury which was initially overlooked, later interpreted as a possible gunshot homicide, and finally identified as a lawn mower related projectile injury when autopsy revealed a piece of metal thread in the main bronchus to the right middle lobe, hemopericardium, and right-sided hemothorax. To our knowledge, this injury mechanism has not previously been reported as a cause of death. This case illustrates the importance of postmortem radiological imaging and interdisciplinary cooperation when establishing manner and cause of death in unusual cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsao, May N.; Mehta, Minesh P.; Whelan, Timothy J.
2005-09-01
Purpose: To systematically review the evidence for the use of stereotactic radiosurgery or stereotactic fractionated radiation therapy in adult patients with malignant glioma. Methods: Key clinical questions to be addressed in this evidence-based review were identified. Outcomes considered were overall survival, quality of life or symptom control, brain tumor control or response and toxicity. MEDLINE (1990-2004 June Week 2), CANCERLIT (1990-2003), CINAHL (1990-2004 June Week 2), EMBASE (1990-2004 Week 25), and the Cochrane library (2004 issue 2) databases were searched using OVID. In addition, the Physician Data Query clinical trials database, the proceedings of the American Society of Clinical Oncologymore » (1997-2004), ASTRO (1997-2004), and the European Society of Therapeutic Radiology and Oncology (ESTRO) (1997-2003) were searched. Data from the literature search were reviewed and tabulated. This process included an assessment of the level of evidence. Results: For patients with newly diagnosed malignant glioma, radiosurgery as boost therapy with conventional external beam radiation was examined in one randomized trial, five prospective cohort studies, and seven retrospective series. There is Level I evidence that the use of radiosurgery boost followed by external beam radiotherapy and carmustine (BCNU) does not confer benefit with respect to overall survival, quality of life, or patterns of failure as compared with external beam radiotherapy and BCNU. There is Level I-III evidence of toxicity associated with radiosurgery boost as compared with external beam radiotherapy alone. The results of the prospective and retrospective studies may be influenced by selection bias. Radiosurgery used as salvage for recurrent or progressive malignant glioma after conventional external beam radiotherapy failure was reported in zero randomized trials, three prospective cohort studies, and five retrospective series. The available data are sparse and insufficient to make absolute recommendations. Stereotactic fractionated radiation therapy has been reported as boost therapy with external beam radiotherapy for patients with newly diagnosed malignant glioma in only three prospective studies. As primary therapy alone without conventional external beam radiotherapy for newly diagnosed malignant glioma patients, stereotactic fractionated radiation therapy has been reported in only one prospective study. There were only three prospective series and two retrospective studies reported for patients with recurrent or progressive malignant glioma. Conclusions: For patients with malignant glioma, there is Level I-III evidence that the use of radiosurgery boost followed by external beam radiotherapy and BCNU does not confer benefit in terms of overall survival, local brain control, or quality of life as compared with external beam radiotherapy and BCNU. The use of radiosurgery boost is associated with increased toxicity. For patients with malignant glioma, there is insufficient evidence regarding the benefits/harms of using radiosurgery at the time progression or recurrence. There is also insufficient evidence regarding the benefits/harms in the use of stereotactic fractionated radiation therapy for patients with newly diagnosed or progressive/recurrent malignant glioma.« less
Guidelines for respiratory motion management in radiation therapy
Matsuo, Yukinori; Onishi, Hiroshi; Nakagawa, Keiichi; Nakamura, Mitsuhiro; Ariji, Takaki; Kumazaki, Yu; Shimbo, Munefumi; Tohyama, Naoki; Nishio, Teiji; Okumura, Masahiko; Shirato, Hiroki; Hiraoka, Masahiro
2013-01-01
Respiratory motion management (RMM) systems in external and stereotactic radiotherapies have been developed in the past two decades. Japanese medical service fee regulations introduced reimbursement for RMM from April 2012. Based on thorough discussions among the four academic societies concerned, these Guidelines have been developed to enable staff (radiation oncologists, radiological technologists, medical physicists, radiotherapy quality managers, radiation oncology nurses, and others) to apply RMM to radiation therapy for tumors subject to respiratory motion, safely and appropriately. PMID:23239175
Functional outcome of knee arthrodesis with a monorail external fixator.
Roy, Alfred Cyril; Albert, Sandeep; Gouse, Mohamad; Inja, Dan Barnabas
2016-04-01
Several methods for obtaining knee arthrodesis have been described in the literature and world; over, the commonest cause for arthrodesis is a failed arthroplasty. Less commonly, as in this series, post-infective or traumatic causes may also require a knee fusion wherein arthroplasty may not be indicated. We present salient advantages along with the radiological and functional outcome of twenty four patients treated with a single monorail external fixator. All patients went on develop fusion at an average of 5.4 months with an average limb length discrepancy of 3 cm (1.5-6 cm). Improvements in functional outcome as assessed by the lower extremity functional score (LEFS), and the SF-36 was significant (p = 0.000). Knee arthrodesis with a single monorail external fixator is a reasonable single-staged salvage option in patients wherein arthroplasty may not be the ideal choice. The outcome, though far from ideal, is definitely positive and predictable.
Nine-year outcome after anatomic stemless shoulder prosthesis: clinical and radiologic results.
Hawi, Nael; Magosch, Petra; Tauber, Mark; Lichtenberg, Sven; Habermeyer, Peter
2017-09-01
Several stemless shoulder implants are available on the market, but only a few studies have presented results with sufficient mid- to long-term follow-up. The present study evaluated clinical and radiologic outcomes 9 years after anatomic stemless shoulder replacement. This is a prospective cohort study evaluating the stemless shoulder prosthesis since 2005. Anatomic stemless shoulder replacement using a single prosthesis was performed in 49 shoulders; 17 underwent total shoulder replacement, and 32 underwent hemiarthroplasty. Forty-three patients were clinically and radiologically monitored after a mean of 9 years (range, 90-127 months; follow-up rate, 88%). The indications for shoulder replacement were primary osteoarthritis in 7 shoulders, post-traumatic in 24, instability in 7, cuff tear arthropathy in 2, postinfectious arthritis in 1, and revision arthroplasty in 2. The Constant-Murley Score improved significantly from 52% to 79% (P < .0001). The active range of motion also increased significantly for flexion from 101° to 118° (P = .022), for abduction from 79° to 105° (P = .02), and for external rotation from 21° to 43° (P < .0001). Radiologic evaluation revealed incomplete radiolucency in 1 patient without clinical significance or further intervention. No revision caused by loosening or countersinking of the humeral implant was observed. The 9-year outcome after stemless shoulder replacement is comparable to that of third- and fourth-generation standard shoulder arthroplasty. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-16
... environmental assessment and finding of no significant impact. FOR FURTHER INFORMATION CONTACT: John Goshen.... Environmental Impacts of the Proposed Action The NRC has determined that, given the continued implementation of... NRC concludes that there are no radiological environmental impacts due to granting the approval of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-31
... impacts. The proposed action will involve no construction or major renovation of any buildings or... to potential non-radiological impacts, there will be no construction or renovation of buildings or... adequate protection of public health and safety and common defense and security.'' The licensee claims that...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boe, Timothy; Lemieux, Paul; Schultheisz, Daniel
2013-07-01
Management of debris and waste from a wide-area radiological incident would probably constitute a significant percentage of the total remediation cost and effort. The U.S. Environmental Protection Agency's (EPA's) Waste Estimation Support Tool (WEST) is a unique planning tool for estimating the potential volume and radioactivity levels of waste generated by a radiological incident and subsequent decontamination efforts. The WEST was developed to support planners and decision makers by generating a first-order estimate of the quantity and characteristics of waste resulting from a radiological incident. The tool then allows the user to evaluate the impact of various decontamination/demolition strategies onmore » the waste types and volumes generated. WEST consists of a suite of standalone applications and Esri{sup R} ArcGIS{sup R} scripts for rapidly estimating waste inventories and levels of radioactivity generated from a radiological contamination incident as a function of user-defined decontamination and demolition approaches. WEST accepts Geographic Information System (GIS) shape-files defining contaminated areas and extent of contamination. Building stock information, including square footage, building counts, and building composition estimates are then generated using the Federal Emergency Management Agency's (FEMA's) Hazus{sup R}-MH software. WEST then identifies outdoor surfaces based on the application of pattern recognition to overhead aerial imagery. The results from the GIS calculations are then fed into a Microsoft Excel{sup R} 2007 spreadsheet with a custom graphical user interface where the user can examine the impact of various decontamination/demolition scenarios on the quantity, characteristics, and residual radioactivity of the resulting waste streams. (authors)« less
Evolution of the clinical review station for enterprise-wide multimedia radiology reporting
NASA Astrophysics Data System (ADS)
Hanlon, William B.; Valtchinov, Vladimir I.; Davis, Scott D.; Lester, James; Khorasani, Ramin; Carrino, John A.; Benfield, Andrew
2000-05-01
Efforts to develop Picture Archiving and Communications Systems (PACS) for the last ten years have concentrated mainly on developing systems for primary interpretation of digital radiological images. Much less attention has been paid to the clinical aspects of the radiology process. Clinical radiology services are an important component of the overall care delivery process, providing information and consultation services to referring physicians, the customers of radiology, in a timely fashion to aid in care decisions. Information management systems (IMS) are playing an increasingly central role in the care delivery process. No suitable commercial PACS or IMS products were available that could effectively provide for the requirements of the clinicians. We endeavored to fill this void at our institution by developing a system to deliver images and text reports electronically on-demand to the referring physicians. This system has evolved substantially since initial deployment eight years ago. As new technologies become available they are evaluated and integrated as appropriate to improve system performance and manageability. Not surprisingly, the internet and World Wide Web (WWW) technology has had the greatest impact on system design in recent years. Additional features have been added over time to provide services for teleradiology, teaching, and research needs. We also discovered that these value-added services give us a competitive edge in attracting new business to our department. Commercial web-based products are now becoming available which do a satisfactory job of providing many of these clinical services. These products are evaluated for integration into our system as they mature. The result is a system that impacts positively on patient care.
Belfi, Lily M; Bartolotta, Roger J; Giambrone, Ashley E; Davi, Caryn; Min, Robert J
2015-06-01
Among methods of "blended learning" (ie, combining online modules with in-class instruction), the "flipped classroom" involves student preclass review of material while reserving class time for interactive knowledge application. We integrated blended learning methodology in a "flipped" introductory clerkship in radiology, and assessed the impact of this approach on the student educational experience (performance and perception). In preparation for the "flipped clerkship," radiology faculty and residents created e-learning modules that were uploaded to an open-source website. The clerkship's 101 rising third-year medical students were exposed to different teaching methods during the course, such as blended learning, traditional lecture learning, and independent learning. Students completed precourse and postcourse knowledge assessments and surveys. Student knowledge improved overall as a result of taking the course. Blended learning achieved greater pretest to post-test improvement of high statistical significance (P value, .0060) compared to lecture learning alone. Blended learning also achieved greater pretest to post-test improvement of borderline statistical significance (P value, .0855) in comparison to independent learning alone. The difference in effectiveness of independent learning versus lecture learning was not statistically significant (P value, .2730). Student perceptions of the online modules used in blended learning portions of the course were very positive. They specifically enjoyed the self-paced interactivity and the ability to return to the modules in the future. Blended learning can be successfully applied to the introductory clerkship in radiology. This teaching method offers educators an innovative and efficient approach to medical student education in radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Bluth, Edward I; Muroff, Lawrence R; Cernigliaro, Joseph G; Moore, Arl V; Smith, Geoffrey G; Flug, Jonathan; DeStigter, Kristen K; Allen, Bibb; Thorwarth, William T; Roberts, Anne C
2015-05-01
The results of a survey sent to practice leaders in the ACR Practice of Radiology Environment Database show that the majority of responding groups will continue to hire recently trained residents and fellows even though they have been unable to take the final ABR diagnostic radiology certifying examination. However, a significant minority of private practice groups will not hire these individuals. The majority of private practices expect the timing change for the ABR certifying examinations to affect their groups' function. In contrast, the majority of academic medical school practices expect little or no impact. Residents and fellows should not expect work time off or protected time to study for the certifying examination or for their maintenance of certification examinations in the future. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Interventional Radiology of Male Varicocele: Current Status
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iaccarino, Vittorio, E-mail: vittorio.iaccarino@unina.it; Venetucci, Pietro
2012-12-15
Varicocele is a fairly common condition in male individuals. Although a minor disease, it may cause infertility and testicular pain. Consequently, it has high health and social impact. Here we review the current status of interventional radiology of male varicocele. We describe the radiological anatomy of gonadal veins and the clinical aspects of male varicocele, particularly the physical examination, which includes a new clinical and ultrasound Doppler maneuver. The surgical and radiological treatment options are also described with the focus on retrograde and antegrade sclerotherapy, together with our long experience with these procedures. Last, we compare the outcomes, recurrence andmore » persistence rates, complications, procedure time and cost-effectiveness of each method. It clearly emerges from this analysis that there is a need for randomized multicentre trials designed to compare the various surgical and percutaneous techniques, all of which are aimed at occlusion of the anterior pampiniform plexus.« less
Early diagnosis of iliofemoral DVT in pregnancy in the emergency department.
van Zyl Smit, Nellis; Govind, Abha; Sharma, Devesh
2012-06-12
The case of a 26-year-old woman who was 23 weeks pregnant is described; the patient presented, on a weekend, to the emergency department (ED) with left groin pain. There were few clinical signs of deep venous thrombosis (DVT) but ED ultrasound (US) showed a left external iliac vein thrombus. This is a new technique in the ED. Not only does this case show the importance of using this technique in the ED, but it also shows the importance of correct training in how to examine for thrombus in the external iliac vein in the pregnant patient. The patient was admitted to the hospital and started on low-molecular-weight heparin. A formal radiology department US performed the next week confirmed the diagnosis of DVT.
Alternative Payment Models in Radiology: The Legislative and Regulatory Roadmap for Reform.
Silva, Ezequiel; McGinty, Geraldine B; Hughes, Danny R; Duszak, Richard
2016-10-01
The Medicare Access and CHIP Reauthorization Act (MACRA) replaces the sustainable growth rate with a payment system based on the Merit-Based Incentive Payment System and incentives for alternative payment model participation. It is important that radiologists understand the statutory requirements of MACRA. This includes the nature of the Merit-Based Incentive Payment System composite performance score and its impact on payments. The timeline for MACRA implementation is fairly aggressive and includes a robust effort to define episode groups, which include radiologic services. A number of organizations, including the ACR, are commenting on the structure of MACRA-directed initiatives. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Corporation in order to complete the backfit; (3) Potential change in the risk to the public from the accidental release of radioactive material; (4) Potential impact on radiological exposure of facility... downtime; (6) The potential safety impact of changes in plant or operational complexity, including the...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Corporation in order to complete the backfit; (3) Potential change in the risk to the public from the accidental release of radioactive material; (4) Potential impact on radiological exposure of facility... downtime; (6) The potential safety impact of changes in plant or operational complexity, including the...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Corporation in order to complete the backfit; (3) Potential change in the risk to the public from the accidental release of radioactive material; (4) Potential impact on radiological exposure of facility... downtime; (6) The potential safety impact of changes in plant or operational complexity, including the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Corporation in order to complete the backfit; (3) Potential change in the risk to the public from the accidental release of radioactive material; (4) Potential impact on radiological exposure of facility... downtime; (6) The potential safety impact of changes in plant or operational complexity, including the...
Code of Federal Regulations, 2013 CFR
2013-01-01
... Corporation in order to complete the backfit; (3) Potential change in the risk to the public from the accidental release of radioactive material; (4) Potential impact on radiological exposure of facility... downtime; (6) The potential safety impact of changes in plant or operational complexity, including the...
Thomson, Norman B; Rawson, James V; Slade, Catherine P; Bledsoe, Martin
2016-05-01
With the US healthcare system on an unsustainable course, change is inevitable. Changes in the healthcare landscape impacting radiology include changing payment models, rapid adoption of digital technology, changes in radiology resident certifying exams, and the rise of consumerism in health care. Academic Radiology will be part of that change with none of its missions spared. What matters is not that change is coming but how Academic Radiology responds to change. Do we ignore, adapt, adopt others' practices, or lead change? Change management or transformation is a management skill set that can be learned and developed. Transformational leadership is a leadership style defined by the relationships between the leaders and the followers and the results they are able to achieve together to meet organizational goals. In this paper, we provide a review of key change management theories, as well as practical advice for self-reflection and development of leadership behaviors that promote effective change management and organizational transformation, particularly in a complex industry like Academic Radiology. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Reicher, Joshua Jay; Reicher, Murray Aaron
2016-06-01
Since 2009, the Federal government distributed over $29 billion to providers who were adopting compliant electronic health record (EHR) technology. With a focus on radiology, we explore how EHR technology impacts interoperability with referring clinicians' EHRs and patient engagement. We also discuss the high-level details of contributing supporting frameworks, specifically Direct messaging and health information service provider (HISP) technology. We characterized Direct messaging, a secure e-mail-like protocol built to allow exchange of encrypted health information online, and the new supporting HISP infrastructure. Statistics related to both the testing and active use of this framework were obtained from DirectTrust.org, an organization whose framework supports Direct messaging use by healthcare organizations. To evaluate patient engagement, we obtained usage data from a radiology-centric patient portal between 2014 and 2015, which in some cases included access to radiology reports. Statistics from 2013 to 2015 showed a rise in issued secure Direct addresses from 8724 to 752,496; a rise in the number of participating healthcare organizations from 667 to 39,751; and a rise in the secure messages sent from 122,842 to 27,316,438. Regarding patient engagement, an average of 234,679 patients per month were provided portal access, with 86,400 patients per month given access to radiology reports. Availability of radiology reports online was strongly associated with increased system usage, with a likelihood ratio of 2.63. The use of certified EHR technology and Direct messaging in the practice of radiology allows for the communication of patient information and radiology results with referring clinicians and increases patient use of patient portal technology, supporting bidirectional radiologist-patient communication.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McHugh, M.G.; Coleman, G.H.
2006-07-01
The contents of a safety basis (SB) are based upon the facility's purpose of operation, radiological inventory, and safety systems in place to mitigate any releases to the employees, general public and environment. Specifically, the radiological inventory is used for facility categorizations (e.g., Category 2, Category 3) and determining the material at risk used in the associated nuclear safety analysis calculations. Radiological inventory discrepancies, referred to as 'mismatches', have the potential to adversely impact the SB. This paper summarizes a process developed to: 1) identify these 'mismatches' based on a facility's radiological inventory, 2) categorize these 'mismatches' according to availablemore » data, and then 3) determine if these 'mismatches' yield either trivial or significant cumulative impacts on credited assumptions associated with a particular facility's SB. The two facilities evaluated for 'mismatches' were the K-1065 Complex and the Above Grade Storage Facility (AGSF). The randomly selected containers from each facility were obtained along with screening the radiological inventories found in the Waste Information Tracking System (WITS) database and the Request for Disposal (RFD) forms. Ideally, the radiological inventory, which is comprised of isotopic data for each container, is maintained in the WITS database. However, the RFD is the official repository record for isotopic data for each container. Historically, neither WITS nor the RFDs were required to contain isotopic data. Based on the WITS and RFD data, the containers were then categorized into five (5) separate conditions: Condition 1) Isotopic data in the RFD matches the isotopic data in WITS; Condition 2) Isotopic data in the RFD does not match the isotopic data in WITS; Condition 3) Isotopic data are in the RFD, but are not in WITS; Condition 4) No isotopic data in the RFD, but isotopic data are found in WITS; Condition 5) No isotopic data found in either the RFD or WITS. The results show trivial cumulative impacts (i.e., no inherent data biases) on credited assumptions associated with the K-1065 Complex and AGSF SBs. Recent random comparisons of WITS and RFDs continue to verify and validate that the administrative and procedural controls are adequate to ensure compliance with the SB for these facilities, thus providing a useful model for evaluating other facilities located at the Department of Energy's Oak Ridge Reservation (DOE-ORR). (authors)« less
Kocbek, Simon; Cavedon, Lawrence; Martinez, David; Bain, Christopher; Manus, Chris Mac; Haffari, Gholamreza; Zukerman, Ingrid; Verspoor, Karin
2016-12-01
Text and data mining play an important role in obtaining insights from Health and Hospital Information Systems. This paper presents a text mining system for detecting admissions marked as positive for several diseases: Lung Cancer, Breast Cancer, Colon Cancer, Secondary Malignant Neoplasm of Respiratory and Digestive Organs, Multiple Myeloma and Malignant Plasma Cell Neoplasms, Pneumonia, and Pulmonary Embolism. We specifically examine the effect of linking multiple data sources on text classification performance. Support Vector Machine classifiers are built for eight data source combinations, and evaluated using the metrics of Precision, Recall and F-Score. Sub-sampling techniques are used to address unbalanced datasets of medical records. We use radiology reports as an initial data source and add other sources, such as pathology reports and patient and hospital admission data, in order to assess the research question regarding the impact of the value of multiple data sources. Statistical significance is measured using the Wilcoxon signed-rank test. A second set of experiments explores aspects of the system in greater depth, focusing on Lung Cancer. We explore the impact of feature selection; analyse the learning curve; examine the effect of restricting admissions to only those containing reports from all data sources; and examine the impact of reducing the sub-sampling. These experiments provide better understanding of how to best apply text classification in the context of imbalanced data of variable completeness. Radiology questions plus patient and hospital admission data contribute valuable information for detecting most of the diseases, significantly improving performance when added to radiology reports alone or to the combination of radiology and pathology reports. Overall, linking data sources significantly improved classification performance for all the diseases examined. However, there is no single approach that suits all scenarios; the choice of the most effective combination of data sources depends on the specific disease to be classified. Copyright © 2016 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) The potential impact of differences in facility type, design, or age on the relevancy and practicality... licensee in order to complete the backfit; (3) Potential change in the risk to the public from the...) Potential impact on radiological exposure or exposure to hazardous chemicals produced from licensed material...
Code of Federal Regulations, 2012 CFR
2012-01-01
...) The potential impact of differences in facility type, design, or age on the relevancy and practicality... licensee in order to complete the backfit; (3) Potential change in the risk to the public from the...) Potential impact on radiological exposure or exposure to hazardous chemicals produced from licensed material...
Code of Federal Regulations, 2010 CFR
2010-01-01
...) The potential impact of differences in facility type, design, or age on the relevancy and practicality... licensee in order to complete the backfit; (3) Potential change in the risk to the public from the...) Potential impact on radiological exposure or exposure to hazardous chemicals produced from licensed material...
Code of Federal Regulations, 2014 CFR
2014-01-01
...) The potential impact of differences in facility type, design, or age on the relevancy and practicality... licensee in order to complete the backfit; (3) Potential change in the risk to the public from the...) Potential impact on radiological exposure or exposure to hazardous chemicals produced from licensed material...
Code of Federal Regulations, 2011 CFR
2011-01-01
...) The potential impact of differences in facility type, design, or age on the relevancy and practicality... licensee in order to complete the backfit; (3) Potential change in the risk to the public from the...) Potential impact on radiological exposure or exposure to hazardous chemicals produced from licensed material...
Tuberculous otitis media developing as a complication of tympanostomy tube insertion.
Kim, Chang Woo; Jin, Jae Won; Rho, Young-Soo
2007-03-01
Primary tuberculous otitis media of which infection focus cannot be found elsewhere in the body is a rare disease. Route of the infection has been hypothesized as Eustachian tube or external auditory canal with tympanic membrane perforation but it is hard to ascertain in the patient. We present a case of an 8-year-old child who suffered chronic otorrhea after tympanostomy tube insertion. The radiological and histopathological findings revealed tuberculous otitis media, which occurred as a complication of tympanostomy tube insertion.
Improved understanding of human anatomy through self-guided radiological anatomy modules.
Phillips, Andrew W; Smith, Sandy G; Ross, Callum F; Straus, Christopher M
2012-07-01
To quantifiably measure the impact of self-instructed radiological anatomy modules on anatomy comprehension, demonstrated by radiology, gross, and written exams. Study guides for independent use that emphasized structural relationships were created for use with two online radiology atlases. A guide was created for each module of the first year medical anatomy course and incorporated as an optional course component. A total of 93 of 96 eligible students participated. All exams were normalized to control for variances in exam difficulty and body region tested. An independent t-test was used to compare overall exam scores with respect to guide completion or incompletion. To account for aptitude differences between students, a paired t-test of each student's exam scores with and without completion of the associated guide was performed, thus allowing students to serve as their own controls. Twenty-one students completed no study guides; 22 completed all six guides; and 50 students completed between one and five guides. Aggregate comparisons of all students' exam scores showed significantly improved mean performance when guides were used (radiology, 57.8% [percentile] vs. 45.1%, P < .001; gross, 56.9% vs. 46.5%, P = .001; written, 57.8% vs. 50.2%, P = .011). Paired comparisons among students who completed between one and five guides demonstrated significantly higher mean practical exam scores when guides were used (radiology, 49.3% [percentile] vs. 36.0%, P = .001; gross, 51.5% vs. 40.4%, P = .005), but not higher written scores. Radiological anatomy study guides significantly improved anatomy comprehension on radiology, gross, and written exams. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
Leveraging Twitter to Maximize the Radiology Meeting Experience.
Kalia, Vivek; Ortiz, Daniel A; Patel, Amy K; Moriarity, Andrew K; Canon, Cheri L; Duszak, Richard
2018-01-01
Over recent years, social media engagement has proliferated among physicians, health care systems, scientific journals, professional societies, and patients. In radiology, Twitter (Twitter Inc, San Francisco, California) has rapidly become the preferred social media engagement tool and is now an essential activity at many large radiology society meetings. Twitter offers a versatile, albeit simple, platform for anyone interested in engaging with others, regardless of title, stature, or geography. In radiology and other medical specialties, year-after-year increases in Twitter engagement before, during, and after professional society meetings continue with widespread positive feedback. This short-form messaging tool also allows users to connect and interact with high-impact individuals and organizations on an ongoing basis (rather than once a year during large meetings). Through live-polling, Twitter also has the power to gather global opinions on issues highly relevant to radiology's future, such as the Medicare Access and CHIP Reauthorization Act of 2015 (MACRA) or breast cancer screening. Also increasingly popular is "live-tweeting" of curated meeting content, which makes information from the meeting accessible to a global audience. Despite the promise of growing professional networks and enabling discussions that cross geographic boundaries, the risks of Twitter use during radiology meetings must be recognized and mitigated. These include posting of unpublished data without consent (eg, slide content captured on camera phones), propagation of misinformation, and copyright infringement. Despite these issues and with an eye towards professionalism, Twitter can nonetheless be used effectively to increase engagement among radiologists, radiology societies, and patients. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Escobar, Pedro Medina; Nydegger, Urs; Risch, Martin; Risch, Lorenz
2012-03-01
An author is generally regarded as an individual "who has made substantial intellectual academic contributions to a published study". However, the extent of the contribution that laboratory medicine professionals have made as authors of research papers in high-impact medical journals remains unclear. From 1 January 2004 to 31 March 2009, 4837 original research articles appeared in the: New England Journal of Medicine, Lancet, Annals of Internal Medicine, JAMA and BMJ. Using authorship as an indicator of intellectual contribution, we analyzed articles that included laboratory medicine parameters in their titles in an observational cross-sectional study. We also extracted data regarding radiological topics that were published during the same time within the same journals. Out of 481 articles concerning laboratory medicine topics, 380 provided information on the affiliations of the authors. At least one author from an institution within the field of laboratory medicine was listed in 212 articles (55.8%). Out of 3943 co-authors, only 756 (19.2%) were affiliated with laboratory medicine institutions. Authors from laboratory medicine institutions were listed as the first, last or corresponding authors in 99 articles (26.1%). The comparative proportions for author affiliation from 55 radiology articles were significantly higher, as 72.7% (p=0.026) of articles and 24.8% (p=0.001) of authors indicated an affiliation with a radiology institution. Radiology professionals from 72.7% of the articles were listed as either the first, last or corresponding authors (p<0.0001). The subgroup analysis revealed that laboratory medicine professionals from North America were significantly less frequently involved as co-authors than were their colleagues from Europe (p=0.04). Laboratory medicine professionals are underrepresented as co-authors in laboratory medicine studies appearing in high-impact general medicine journals.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-06
... 2003-18, Supplement 2, ``Use of Nuclear Energy Institute (NEI) 99-01, Methodology for Development of... radiological emergency. Environmental Impacts of the Proposed Action The NRC has completed its environmental... environmental impacts are [[Page 61780
Northern Marshall Islands radiological survey: sampling and analysis summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robison, W.L.; Conrado, C.L.; Eagle, R.J.
1981-07-23
A radiological survey was conducted in the Northern Marshall Islands to document reamining external gamma exposures from nuclear tests conducted at Enewetak and Bikini Atolls. An additional program was later included to obtain terrestrial and marine samples for radiological dose assessment for current or potential atoll inhabitants. This report is the first of a series summarizing the results from the terrestrial and marine surveys. The sample collection and processing procedures and the general survey methodology are discussed; a summary of the collected samples and radionuclide analyses is presented. Over 5400 samples were collected from the 12 atolls and 2 islandsmore » and prepared for analysis including 3093 soil, 961 vegetation, 153 animal, 965 fish composite samples (average of 30 fish per sample), 101 clam, 50 lagoon water, 15 cistern water, 17 groundwater, and 85 lagoon sediment samples. A complete breakdown by sample type, atoll, and island is given here. The total number of analyses by radionuclide are 8840 for /sup 241/Am, 6569 for /sup 137/Cs, 4535 for /sup 239 +240/Pu, 4431 for /sup 90/Sr, 1146 for /sup 238/Pu, 269 for /sup 241/Pu, and 114 each for /sup 239/Pu and /sup 240/Pu. A complete breakdown by sample category, atoll or island, and radionuclide is also included.« less
Incorporating intelligence into structured radiology reports
NASA Astrophysics Data System (ADS)
Kahn, Charles E.
2014-03-01
The new standard for radiology reporting templates being developed through the Integrating the Healthcare Enterprise (IHE) and DICOM organizations defines the storage and exchange of reporting templates as Hypertext Markup Language version 5 (HTML5) documents. The use of HTML5 enables the incorporation of "dynamic HTML," in which documents can be altered in response to their content. HTML5 documents can employ JavaScript, the HTML Document Object Model (DOM), and external web services to create intelligent reporting templates. Several reporting templates were created to demonstrate the use of scripts to perform in-template calculations and decision support. For example, a template for adrenal CT was created to compute contrast washout percentage from input values of precontrast, dynamic postcontrast, and delayed adrenal nodule attenuation values; the washout value can used to classify an adrenal nodule as a benign cortical adenoma. Dynamic templates were developed to compute volumes and apply diagnostic criteria, such as those for determination of internal carotid artery stenosis. Although reporting systems need not use a web browser to render the templates or their contents, the use of JavaScript creates innumerable opportunities to construct highly sophisticated HTML5 reporting templates. This report demonstrates the ability to incorporate dynamic content to enhance the use of radiology reporting templates.
Wilson, Todd; Chang, Arthur; Berro, Andre; Still, Aaron; Brown, Clive; Demma, Andrew; Nemhauser, Jeffrey; Martin, Colleen; Salame-Alfie, Adela; Fisher-Tyler, Frieda; Smith, Lee; Grady-Erickson, Onalee; Alvarado-Ramy, Francisco; Brunette, Gary; Ansari, Armin; McAdam, David; Marano, Nina
2012-10-01
On March 11, 2011, a magnitude 9.0 earthquake and subsequent tsunami damaged nuclear reactors at the Fukushima Daiichi complex in Japan, resulting in radionuclide release. In response, US officials augmented existing radiological screening at its ports of entry (POEs) to detect and decontaminate travelers contaminated with radioactive materials. During March 12 to 16, radiation screening protocols detected 3 travelers from Japan with external radioactive material contamination at 2 air POEs. Beginning March 23, federal officials collaborated with state and local public health and radiation control authorities to enhance screening and decontamination protocols at POEs. Approximately 543 000 (99%) travelers arriving directly from Japan at 25 US airports were screened for radiation contamination from March 17 to April 30, and no traveler was detected with contamination sufficient to require a large-scale public health response. The response highlighted synergistic collaboration across government levels and leveraged screening methods already in place at POEs, leading to rapid protocol implementation. Policy development, planning, training, and exercising response protocols and the establishment of federal authority to compel decontamination of travelers are needed for future radiological responses. Comparison of resource-intensive screening costs with the public health yield should guide policy decisions, given the historically low frequency of contaminated travelers arriving during radiological disasters.
Modification of Shirt Buttons for Retrospective Radiation Dosimetry after a Radiological Event
Marino, Stephen A.; Johnson, Gary W.; Schiff, Peter B.; Brenner, David J.
2010-01-01
Preliminary results are presented for a personal radiation dosimeter in the form of a clothing button to provide gamma-ray dose estimation for clinically significant external radiation exposures to the general public due to a radiological incident, such as a Radiological Dispersal Device. Rods of thermoluminescent material (LiF:Mg,Ti and LiF:Mg,Cu,P) were encapsulated in plastic “buttons”, attached to shirts, and subjected to three cycles of home or commercial laundering or dry cleaning, including ironing or pressing. The buttons were subsequently exposed to doses of 137Cs gamma rays ranging from 0.75 to 8.2 Gy. The rods were removed from the buttons and their light output compared to their responses when bare or to the responses of a set of calibration rods of the same type and from the same manufacturer. In all three of the comparisons for LiF:Mg,Ti rods the relative responses of the rods in buttons changed by 2-6% relative to the same rods before cleaning. In both comparisons for LiF:Mg,Cu,P rods, the response of laundered rods was 1-3% lower than for the same rods before cleaning. Both these materials are potential candidates for button dosimeters. PMID:21451325
Metwali, Hussam; Fahlbusch, Rudolf
2017-06-01
Supradiaphragmatic hematoma is a type of hematoma that occurs after transsphenoidal (TS) resection of pituitary adenoma and requires special management. Two patients had symptomatic supradiaphragmatic hematomas after total TS resection of pituitary adenomas in the absence of vascular anomalies. Both patients also had hydrocephalus at the time of diagnosis of the hematoma. The initial endoscopic endonasal inspection showed no subdiaphragmatic bleeding. The hematoma was evacuated via a frontolateral approach after insertion of an external ventricular drain (EVD). The supradiaphragmatic hematoma could be clinically and radiologically distinguished. It presented early with visual deterioration without headache. The patients developed hydrocephalus, which was associated with deterioration of level of consciousness. Radiologically, the hematoma filled the suprasellar space and was associated with the extension of bleeding in the basal cisterns. Recovery was good in both patients. There were no permanent neurologic deficits. The EVD was removed in both patients. One patient required a ventriculoperitoneal shunt because of delayed hydrocephalus. Supradiaphragmatic hematoma can be clinically and radiologically distinguished from other types of hematoma occurring after TS resection of pituitary adenoma. Transcranial surgery should be performed to manage supradiaphragmatic hematoma, when symptomatic. Insertion of an EVD at the time of evacuation is mandatory to relax the brain and to alleviate the hydrocephalus. Copyright © 2017 Elsevier Inc. All rights reserved.
Carral, Florentino; Ayala, María del Carmen; Jiménez, Ana Isabel; García, Concepción
2016-02-01
Routine thyroid ultrasound examination in a single medical appointment is rarely performed in Spain. The objective of this study was to evaluate the care and economic impact of thyroid US examination in a single endocrine appointment. A prospective, observational, descriptive study was conducted to analyze data from 2274 patients (mean age, 59±16 years; 83% females) performed at least one thyroid US in a single visit to an endocrinology clinic during 2013 and 2014. The number of endocrine acts with thyroid US, single endocrine and US acts without review, and the change in the number of thyroid US requested by endocrinologists to the radiology department and total thyroid US examinations performed at the radiology department during the study period were assessed. In 2013 and 2014, 2558 endocrine acts with thyroid US were performed, of which 42.2% were single endocrine and US appointments without a second endocrine act, with estimated savings of €58,946.40. As compared to 2012, the number of thyroid US requested by endocrinologists to the radiology department decreased by 43.3% and 86.0% in 2013 and 2014 respectively, and total thyroid US performed by the radiology department decreased by 28.1% and 68.3% respectively, with estimated savings of €94,441.36. Thyroid US examination in a single endocrine appointment allows for decreasing the number of both second endocrine acts and thyroid US examinations performed at the radiology department, thus reducing the number of unnecessary clinic visits and promoting considerable economic savings. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.
Cutting costs: the impact of price lists on the cost development at the emergency department.
Schilling, Ulf Martin
2010-12-01
It was shown that physicians working at the Swedish emergency department (ED) are unaware of the costs for investigations performed. This study evaluated the possible impact of price lists on the overall laboratory and radiology costs at the ED of a Swedish university hospital. Price lists including the most common laboratory analyses and radiological investigations at the ED were created. The lists were distributed to all internal medicine physicians by e-mail and exposed above their working stations continually. No lists were provided for the orthopaedic control group. The average costs for laboratory and radiological investigations during the months of June and July 2007 and 2008 were calculated. Neither clinical nor admission procedures were changed. The physicians were blinded towards the study. Statistical analysis was performed using the Student's t-test. A total of 1442 orthopaedic and 1585 medical patients were attended to in 2007. In 2008, 1467 orthopaedic and 1637 medical patients required emergency service. The average costs per patient were 980.27 SKR (98€)/999.41 SKR (100€, +1.95%) for orthopaedic and 1081.36 SKR (108€)/877.3 SKR (88€, -18.8%) for medical patients. Laboratory costs decreased by 9% in orthopaedic and 21.4% in medical patients. Radiology costs changed +5.4% in orthopaedic and -20.59% in medical patients. The distribution and promotion of price lists as a tool at the ED to heighten cost awareness resulted in a major decrease in the investigation costs. A significant decrease in radiological costs could be observed. It can be concluded that price lists are an effective tool to cut costs in public healthcare.
Association of h-index of Editorial Board Members and Impact Factor among Radiology Journals.
Asnafi, Solmaz; Gunderson, Tina; McDonald, Robert J; Kallmes, David F
2017-02-01
h-Index has been proposed as a useful bibliometric measure for quantifying research productivity. In this current study, we analyzed h-indices of editorial board members of Radiology journals and tested the hypothesis that editorial board members of Radiology journals with higher impact factors (IF) have higher h-indices. Sixty-two Radiology journals with IF >1 were included. Editorial board members were identified using the journals' websites. Editors' affiliations and research fields of interest were used to distinguish investigators with similar names. Bibliometric indices including number of publications, total citations, citations per publication, and h-index for each editorial board member were obtained using the Web of Science database. Chi-square or Wilcoxon rank-sum tests were used to test for differences in bibliographic measures or demographics between groups. Among the editorial boards of 62 journals, the median [interquartile range] board h-index was 26 [18, 31] and had 36 [17, 56] members. The median journal IF was 2.27 [1.74, 3.31]. We identified a total of 2204 distinct editors; they had a median [interquartile range] h-index of 23 [13, 35], 120 [58, 215] total publications, 1938 [682, 4634] total citations, and an average of 15.7 [9.96, 24.8] citations per publication. The boards of journals with IF above the median had significantly higher h-indices (P = .002), total publications (P = .01), and total and average citations (both any [P = .003, .009] and nonself-citations [P = .001, .002]) than journals below the median. Our data indicate that board members of Radiology journals with higher IF have greater h-indices compared to lower IF journals. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Presentation to publication: proportion of abstracts published for ESPR, SPR and IPR.
Shelmerdine, Susan C; Lynch, Jeremy O; Langan, Dean; Arthurs, Owen J
2016-09-01
Advancement of knowledge requires presentation and publication of high-quality scientific research. Studies submitted for presentation undergo initial peer review before acceptance and the rate of subsequent publication may be taken as an indicator of access to publication for pediatric radiology studies. Evaluate the proportion of abstracts also published in journals for pediatric radiology conferences and identify factors associated with publication success. All Medline articles that originated from oral presentations at the European Society for Paediatric Radiology (ESPR), the Society for Pediatric Radiology (SPR) or the International Pediatric Radiology (IPR) conferences between 2010 - 2012 were evaluated. Descriptive statistics to evaluate published and unpublished groups were calculated overall and split by characteristics of the abstracts such as number of authors. Overall number of abstracts published was 300/715 (41.9%), with most articles published in radiology specific journals (181/300; 60.3%), with median impact factor 2.31 (interquartile range [IQR]: 1.65-3.14, range: 0-18.03). Those published after the conference (262/300, 87.6%) had a median time to publication of 18 months and for those published before, the median time was -11 months. Median sample size in published articles was 52 (IQR: 33-105, range: 1-6,351). Of pediatric radiology oral abstracts, 41.9% achieve publication after a period of at least 3 years from presentation. Studies originating from certain countries and on certain subspecialty topics were more likely to get published.
Canadian Association of Radiologists White Paper on Artificial Intelligence in Radiology.
Tang, An; Tam, Roger; Cadrin-Chênevert, Alexandre; Guest, Will; Chong, Jaron; Barfett, Joseph; Chepelev, Leonid; Cairns, Robyn; Mitchell, J Ross; Cicero, Mark D; Poudrette, Manuel Gaudreau; Jaremko, Jacob L; Reinhold, Caroline; Gallix, Benoit; Gray, Bruce; Geis, Raym
2018-05-01
Artificial intelligence (AI) is rapidly moving from an experimental phase to an implementation phase in many fields, including medicine. The combination of improved availability of large datasets, increasing computing power, and advances in learning algorithms has created major performance breakthroughs in the development of AI applications. In the last 5 years, AI techniques known as deep learning have delivered rapidly improving performance in image recognition, caption generation, and speech recognition. Radiology, in particular, is a prime candidate for early adoption of these techniques. It is anticipated that the implementation of AI in radiology over the next decade will significantly improve the quality, value, and depth of radiology's contribution to patient care and population health, and will revolutionize radiologists' workflows. The Canadian Association of Radiologists (CAR) is the national voice of radiology committed to promoting the highest standards in patient-centered imaging, lifelong learning, and research. The CAR has created an AI working group with the mandate to discuss and deliberate on practice, policy, and patient care issues related to the introduction and implementation of AI in imaging. This white paper provides recommendations for the CAR derived from deliberations between members of the AI working group. This white paper on AI in radiology will inform CAR members and policymakers on key terminology, educational needs of members, research and development, partnerships, potential clinical applications, implementation, structure and governance, role of radiologists, and potential impact of AI on radiology in Canada. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Data Fusion for a Vision-Radiological System for Source Tracking and Discovery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Enqvist, Andreas; Koppal, Sanjeev
2015-07-01
A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for themore » purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)« less
Campana, Lorenzo; Breitbeck, Robert; Bauer-Kreuz, Regula; Buck, Ursula
2016-05-01
This study evaluated the feasibility of documenting patterned injury using three dimensions and true colour photography without complex 3D surface documentation methods. This method is based on a generated 3D surface model using radiologic slice images (CT) while the colour information is derived from photographs taken with commercially available cameras. The external patterned injuries were documented in 16 cases using digital photography as well as highly precise photogrammetry-supported 3D structured light scanning. The internal findings of these deceased were recorded using CT and MRI. For registration of the internal with the external data, two different types of radiographic markers were used and compared. The 3D surface model generated from CT slice images was linked with the photographs, and thereby digital true-colour 3D models of the patterned injuries could be created (Image projection onto CT/IprojeCT). In addition, these external models were merged with the models of the somatic interior. We demonstrated that 3D documentation and visualization of external injury findings by integration of digital photography in CT/MRI data sets is suitable for the 3D documentation of individual patterned injuries to a body. Nevertheless, this documentation method is not a substitution for photogrammetry and surface scanning, especially when the entire bodily surface is to be recorded in three dimensions including all external findings, and when precise data is required for comparing highly detailed injury features with the injury-inflicting tool.
Kolo, Matthew Tikpangi; Khandaker, Mayeen Uddin; Amin, Yusoff Mohd; Abdullah, Wan Hasiah Binti
2016-01-01
Following the increasing demand of coal for power generation, activity concentrations of primordial radionuclides were determined in Nigerian coal using the gamma spectrometric technique with the aim of evaluating the radiological implications of coal utilization and exploitation in the country. Mean activity concentrations of 226Ra, 232Th, and 40K were 8.18±0.3, 6.97±0.3, and 27.38±0.8 Bq kg-1, respectively. These values were compared with those of similar studies reported in literature. The mean estimated radium equivalent activity was 20.26 Bq kg-1 with corresponding average external hazard index of 0.05. Internal hazard index and representative gamma index recorded mean values of 0.08 and 0.14, respectively. These values were lower than their respective precautionary limits set by UNSCEAR. Average excess lifetime cancer risk was calculated to be 0.04×10-3, which was insignificant compared with 0.05 prescribed by ICRP for low level radiation. Pearson correlation matrix showed significant positive relationship between 226Ra and 232Th, and with other estimated hazard parameters. Cumulative mean occupational dose received by coal workers via the three exposure routes was 7.69 ×10-3 mSv y-1, with inhalation pathway accounting for about 98%. All radiological hazard indices evaluated showed values within limits of safety. There is, therefore, no likelihood of any immediate radiological health hazards to coal workers, final users, and the environment from the exploitation and utilization of Maiganga coal.
Kolo, Matthew Tikpangi; Khandaker, Mayeen Uddin; Amin, Yusoff Mohd; Abdullah, Wan Hasiah Binti
2016-01-01
Following the increasing demand of coal for power generation, activity concentrations of primordial radionuclides were determined in Nigerian coal using the gamma spectrometric technique with the aim of evaluating the radiological implications of coal utilization and exploitation in the country. Mean activity concentrations of 226Ra, 232Th, and 40K were 8.18±0.3, 6.97±0.3, and 27.38±0.8 Bq kg-1, respectively. These values were compared with those of similar studies reported in literature. The mean estimated radium equivalent activity was 20.26 Bq kg-1 with corresponding average external hazard index of 0.05. Internal hazard index and representative gamma index recorded mean values of 0.08 and 0.14, respectively. These values were lower than their respective precautionary limits set by UNSCEAR. Average excess lifetime cancer risk was calculated to be 0.04×10−3, which was insignificant compared with 0.05 prescribed by ICRP for low level radiation. Pearson correlation matrix showed significant positive relationship between 226Ra and 232Th, and with other estimated hazard parameters. Cumulative mean occupational dose received by coal workers via the three exposure routes was 7.69 ×10−3 mSv y-1, with inhalation pathway accounting for about 98%. All radiological hazard indices evaluated showed values within limits of safety. There is, therefore, no likelihood of any immediate radiological health hazards to coal workers, final users, and the environment from the exploitation and utilization of Maiganga coal. PMID:27348624
[Digital teaching archive. Concept, implementation, and experiences in a university setting].
Trumm, C; Dugas, M; Wirth, S; Treitl, M; Lucke, A; Küttner, B; Pander, E; Clevert, D-A; Glaser, C; Reiser, M
2005-08-01
Film-based teaching files require a substantial investment in human, logistic, and financial resources. The combination of computer and network technology facilitates the workflow integration of distributing radiologic teaching cases within an institution (intranet) or via the World Wide Web (Internet). A digital teaching file (DTF) should include the following basic functions: image import from different sources and of different formats, editing of imported images, uniform case classification, quality control (peer review), a controlled access of different user groups (in-house and external), and an efficient retrieval strategy. The portable network graphics image format (PNG) is especially suitable for DTFs because of several features: pixel support, 2D-interlacing, gamma correction, and lossless compression. The American College of Radiology (ACR) "Index for Radiological Diagnoses" is hierarchically organized and thus an ideal classification system for a DTF. Computer-based training (CBT) in radiology is described in numerous publications, from supplementing traditional learning methods to certified education via the Internet. Attractiveness of a CBT application can be increased by integration of graphical and interactive elements but makes workflow integration of daily case input more difficult. Our DTF was built with established Internet instruments and integrated into a heterogeneous PACS/RIS environment. It facilitates a quick transfer (DICOM_Send) of selected images at the time of interpretation to the DTF and access to the DTF application at any time anywhere within the university hospital intranet employing a standard web browser. A DTF is a small but important building block in an institutional strategy of knowledge management.
Leach, A W; Mumford, J D
2008-01-01
The Pesticide Environmental Accounting (PEA) tool provides a monetary estimate of environmental and health impacts per hectare-application for any pesticide. The model combines the Environmental Impact Quotient method and a methodology for absolute estimates of external pesticide costs in UK, USA and Germany. For many countries resources are not available for intensive assessments of external pesticide costs. The model converts external costs of a pesticide in the UK, USA and Germany to Mediterranean countries. Economic and policy applications include estimating impacts of pesticide reduction policies or benefits from technologies replacing pesticides, such as sterile insect technique. The system integrates disparate data and approaches into a single logical method. The assumptions in the system provide transparency and consistency but at the cost of some specificity and precision, a reasonable trade-off for a method that provides both comparative estimates of pesticide impacts and area-based assessments of absolute impacts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen Jing
2008-08-07
This study used the Monte-Carlo code MCNPX to determine mean absorbed doses to the embryo and foetus when the mother is exposed to external muon fields. Monoenergetic muons ranging from 20 MeV to 50 GeV were considered. The irradiation geometries include anteroposterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT), isotropic (ISO), and top-down (TOP). At each of these irradiation geometries, absorbed doses to the foetal body were calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months, respectively. Muon fluence-to-absorbed-dose conversion coefficients were derived for the four prenatal ages. Since such conversion coefficients aremore » yet unknown, the results presented here fill a data gap.« less
Szymańska, Anna; Szymański, Marcin; Czekajska-Chehab, Elżbieta; Szczerbo-Trojanowska, Małgorzata
2014-07-01
Juvenile nasopharyngeal angiofibroma is a benign lesion with locally aggressive nature. Knowledge of its typical growth patterns is crucial for precise preoperative staging and adequate preoperative patient counseling. This pictorial essay focuses on characteristic radiological features and paths of invasive growth of this rare tumor. Also, the impact of accurate preoperative evaluation of tumor extensions on surgical planning and results of treatment are discussed. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Code of Federal Regulations, 2014 CFR
2014-01-01
... availability of such resources; (8) The potential impact of differences in facility type, design or age on the... licensee or applicant in order to complete the backfit; (3) Potential change in the risk to the public from the accidental off-site release of radioactive material; (4) Potential impact on radiological exposure...
Code of Federal Regulations, 2010 CFR
2010-01-01
... availability of such resources; (8) The potential impact of differences in facility type, design or age on the... licensee or applicant in order to complete the backfit; (3) Potential change in the risk to the public from the accidental off-site release of radioactive material; (4) Potential impact on radiological exposure...
Code of Federal Regulations, 2012 CFR
2012-01-01
... availability of such resources; (8) The potential impact of differences in facility type, design or age on the... licensee or applicant in order to complete the backfit; (3) Potential change in the risk to the public from the accidental off-site release of radioactive material; (4) Potential impact on radiological exposure...
10 CFR 72.90 - General considerations.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C WASTE Siting Evaluation Factors... environmental impact of the ISFSI or MRS must be investigated and assessed. (b) Proposed sites for the ISFSI or... proposed site for an MRS, the potential for radiological and other environmental impacts on the region must...
10 CFR 72.90 - General considerations.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C WASTE Siting Evaluation Factors... environmental impact of the ISFSI or MRS must be investigated and assessed. (b) Proposed sites for the ISFSI or... proposed site for an MRS, the potential for radiological and other environmental impacts on the region must...
French Sizing of Medical Devices is not Fit for Purpose
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kibriya, Nabil, E-mail: nabskib@yahoo.co.uk; Hall, Rebecca; Powell, Steven
PurposeThe purpose of the study is to quantify the variation in the metric equivalent of French size in a range of medical devices, from various manufacturers, used in interventional radiology.MethodsThe labelling of a range of catheters, introducers, drains, balloons, stents, and endografts was examined. Products were chosen to achieve a broad range of French sizes from several manufacturers. To assess manufacturing accuracy, eight devices were selected for measurement using a laser micrometer. The external diameters of three specimens of each device were measured at centimeter intervals along the length of the device to ensure uniformity.ResultsA total of 200 labels ofmore » interventional radiology equipment were scrutinized. The results demonstrate a wide variation in the metric equivalent of French sizing. Labelled products can vary in diameter across the product range by up to 0.79 mm.The devices selected for measurement with the non-contact laser micrometer demonstrate acceptable manufacturing consistency. The external diameter differed by 0.05 mm on average.ConclusionsOur results demonstrate wide variation in the interpretation of the French scale by different manufacturers of medical devices. This has the potential to lead to problems using coaxial systems especially when the products are from different manufacturers. It is recommended that standard labelling should be employed by all manufacturers conveying specific details of the equipment. Given the wide variation in the interpretation of the French scale, our opinion is that this scale either needs to be abandoned or be strictly defined and followed.« less
Schell, Hanna; Thompson, Mark S; Bail, Hermann J; Hoffmann, Jan-Erik; Schill, Alexander; Duda, Georg N; Lienau, Jasmin
2008-10-20
This study aimed to mechanically produce a standardized ovine model for a critically delayed bone union. A tibial osteotomy was stabilized with either a rigid (group I) or mechanically critical (group II) external fixator in sheep. Interfragmentary movements and ground reaction forces were monitored throughout the healing period of 9 weeks. After sacrifice at 6 weeks, 9 weeks and 6 months, radiographs were taken and the tibiae were examined mechanically. Interfragmentary movements were considerably larger in group II throughout the healing period. Unlike group I, the operated limb in group II did not return to full weight bearing during the treatment period. Radiographic and mechanical observations showed significantly inferior bone healing in group II at 6 and 9 weeks compared to group I. After 6 months, five sheep treated with the critical fixator showed radiological bridging of the osteotomy, but the biomechanical strength of the repair was still inferior to group I at 9 weeks. The remaining three animals had even developed a hypertrophic non-union. In this study, mechanical instability was employed to induce a critically delayed healing model in sheep. In some cases, this approach even led to the development of a hypertrophic non-union. The mechanical induction of critical bone healing using an external fixation device is a reasonable attempt to investigate the patho-physiological healing cascade without suffering from any biological intervention. Therefore, the presented ovine model provides the basis for a comparative evaluation of mechanisms controlling delayed and standard bone healing.
Deep Learning to Classify Radiology Free-Text Reports.
Chen, Matthew C; Ball, Robyn L; Yang, Lingyao; Moradzadeh, Nathaniel; Chapman, Brian E; Larson, David B; Langlotz, Curtis P; Amrhein, Timothy J; Lungren, Matthew P
2018-03-01
Purpose To evaluate the performance of a deep learning convolutional neural network (CNN) model compared with a traditional natural language processing (NLP) model in extracting pulmonary embolism (PE) findings from thoracic computed tomography (CT) reports from two institutions. Materials and Methods Contrast material-enhanced CT examinations of the chest performed between January 1, 1998, and January 1, 2016, were selected. Annotations by two human radiologists were made for three categories: the presence, chronicity, and location of PE. Classification of performance of a CNN model with an unsupervised learning algorithm for obtaining vector representations of words was compared with the open-source application PeFinder. Sensitivity, specificity, accuracy, and F1 scores for both the CNN model and PeFinder in the internal and external validation sets were determined. Results The CNN model demonstrated an accuracy of 99% and an area under the curve value of 0.97. For internal validation report data, the CNN model had a statistically significant larger F1 score (0.938) than did PeFinder (0.867) when classifying findings as either PE positive or PE negative, but no significant difference in sensitivity, specificity, or accuracy was found. For external validation report data, no statistical difference between the performance of the CNN model and PeFinder was found. Conclusion A deep learning CNN model can classify radiology free-text reports with accuracy equivalent to or beyond that of an existing traditional NLP model. © RSNA, 2017 Online supplemental material is available for this article.
Assessment of natural radionuclides and its radiological hazards from tiles made in Nigeria
NASA Astrophysics Data System (ADS)
Joel, E. S.; Maxwell, O.; Adewoyin, O. O.; Ehi-Eromosele, C. O.; Embong, Z.; Saeed, M. A.
2018-03-01
Activity concentration of 10 different brands of tiles made in Nigeria were analyzed using High purity Germanium gamma detector and its hazard indices such as absorbed dose rate, radium equivalent activity, external Hazard Index (Hex), internal Hazard Index (Hin), Annual Effective Dose (mSv/y), Gamma activity Index (Iγ) and Alpha Index (Iα) were determined. The result showed that the average activity concentrations of radionuclides (226Ra, 232Th and 40K) content are within the recommended limit. The average radium equivalent is within the recommended limit of 370 Bq/kg. The result obtained further showed that the mean values for the absorbed dose rate (D), external and internal hazard index, the annual effective dose (AEDR) equivalent, gamma activity index and Alpha Index were: 169.22 nGyh-1, 0.95 and 1.14, 1.59 mSv/y, 1.00 Sv yr-1 and 0.34 respectively. The result established that radiological hazards such as absorbed dose rate, internal hazard, annual effective dose rate, gamma activity index and Alpha Index for some samples are found to be slightly close or above international recommended values. The result for the present study was compared with tiles sample from others countries, it was observed that the concentration of tiles made in Nigeria and other countries are closer, however recommends proper radiation monitoring for some tiles made in Nigeria before usage due to the long term health effect.
beta- and gamma-Comparative dose estimates on Enewetak Atoll.
Crase, K W; Gudiksen, P H; Robison, W L
1982-05-01
Enewetak Atoll is one of the Pacific atolls used for atmospheric testing of U.S. nuclear weapons. Beta dose and gamma-ray exposure measurements were made on two islands of the Enewetak Atoll during July-August 1976 to determine the beta and low energy gamma-contribution to the total external radiation doses to the returning Marshallese. Measurements were made at numerous locations with thermoluminescent dosimeters (TLD), pressurized ionization chambers, portable NaI detectors, and thin-window pancake GM probes. Results of the TLD measurements with and without a beta-attenuator indicate that approx. 29% of the total dose rate at 1 m in air is due to beta- or low energy gamma-contribution. The contribution at any particular site, however, is somewhat dependent on ground cover, since a minimal amount of vegetation will reduce it significantly from that over bare soil, but thick stands of vegetation have little effect on any further reductions. Integral 30-yr external shallow dose estimates for future inhabitants were made and compared with external dose estimates of a previous large scale radiological survey (En73). Integral 30-yr shallow external dose estimates are 25-50% higher than whole body estimates. Due to the low penetrating ability of the beta's or low energy gamma's, however, several remedial actions can be taken to reduce the shallow dose contribution to the total external dose.
Foster, Allison; Morandi, Federica; May, Elizabeth
2015-01-01
Previous reports describing the prevalence of ear diseases in dogs have primarily been based on dogs presenting with clinical signs of disease. The prevalence of subclinical ear disease remains unknown. The purpose of this cross-sectional retrospective study was to describe the prevalence of lesions consistent with middle and external ear disease in dogs presented for multidetector computed tomography (CT) of the head and/or cranial cervical spine at our hospital during the period of July 2011 and August 2013. For each included dog, data recorded were signalment, CT findings, diagnosis, and treatment. A total of 199 dogs met inclusion criteria. Nineteen dogs (9.5%) were referred for evaluation of suspected ear disease and 27 dogs (13.5%) had histories or physical examination findings consistent with otitis externa. A total of 163 dogs (81.9%) had CT lesions consistent with external ear disease (i.e. ear canal mineralization, external canal thickening, and/or narrowing of the external canal). Thirty-nine dogs (19.5%) had CT lesions consistent with middle ear disease (i.e. soft tissue attenuating/fluid material in the tympanic bullae, bulla wall thickening or lysis, and/or periosteal proliferation of the temporal bone). Findings from this study indicated that the prevalence of external and middle ear disease in dogs could be higher than that previously reported. © 2014 American College of Veterinary Radiology.
McBee, Morgan P; Awan, Omer A; Colucci, Andrew T; Ghobadi, Comeron W; Kadom, Nadja; Kansagra, Akash P; Tridandapani, Srini; Auffermann, William F
2018-03-29
As radiology is inherently a data-driven specialty, it is especially conducive to utilizing data processing techniques. One such technique, deep learning (DL), has become a remarkably powerful tool for image processing in recent years. In this work, the Association of University Radiologists Radiology Research Alliance Task Force on Deep Learning provides an overview of DL for the radiologist. This article aims to present an overview of DL in a manner that is understandable to radiologists; to examine past, present, and future applications; as well as to evaluate how radiologists may benefit from this remarkable new tool. We describe several areas within radiology in which DL techniques are having the most significant impact: lesion or disease detection, classification, quantification, and segmentation. The legal and ethical hurdles to implementation are also discussed. By taking advantage of this powerful tool, radiologists can become increasingly more accurate in their interpretations with fewer errors and spend more time to focus on patient care. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Meaningful Peer Review in Radiology: A Review of Current Practices and Potential Future Directions.
Moriarity, Andrew K; Hawkins, C Matthew; Geis, J Raymond; Dreyer, Keith J; Kamer, Aaron P; Khandheria, Paras; Morey, Jose; Whitfill, James; Wiggins, Richard H; Itri, Jason N
2016-12-01
The current practice of peer review within radiology is well developed and widely implemented compared with other medical specialties. However, there are many factors that limit current peer review practices from reducing diagnostic errors and improving patient care. The development of "meaningful peer review" requires a transition away from compliance toward quality improvement, whereby the information and insights gained facilitate education and drive systematic improvements that reduce the frequency and impact of diagnostic error. The next generation of peer review requires significant improvements in IT functionality and integration, enabling features such as anonymization, adjudication by multiple specialists, categorization and analysis of errors, tracking, feedback, and easy export into teaching files and other media that require strong partnerships with vendors. In this article, the authors assess various peer review practices, with focused discussion on current limitations and future needs for meaningful peer review in radiology. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Big Data and the Future of Radiology Informatics.
Kansagra, Akash P; Yu, John-Paul J; Chatterjee, Arindam R; Lenchik, Leon; Chow, Daniel S; Prater, Adam B; Yeh, Jean; Doshi, Ankur M; Hawkins, C Matthew; Heilbrun, Marta E; Smith, Stacy E; Oselkin, Martin; Gupta, Pushpender; Ali, Sayed
2016-01-01
Rapid growth in the amount of data that is electronically recorded as part of routine clinical operations has generated great interest in the use of Big Data methodologies to address clinical and research questions. These methods can efficiently analyze and deliver insights from high-volume, high-variety, and high-growth rate datasets generated across the continuum of care, thereby forgoing the time, cost, and effort of more focused and controlled hypothesis-driven research. By virtue of an existing robust information technology infrastructure and years of archived digital data, radiology departments are particularly well positioned to take advantage of emerging Big Data techniques. In this review, we describe four areas in which Big Data is poised to have an immediate impact on radiology practice, research, and operations. In addition, we provide an overview of the Big Data adoption cycle and describe how academic radiology departments can promote Big Data development. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Implications of environmental externalities assessments for solar thermal powerplants
NASA Astrophysics Data System (ADS)
Lee, A. D.; Baechler, M. C.
1991-03-01
Externalities are those impacts of one activity on other activities that are not priced in the marketplace. An externality is said to exist when two conditions hold: (1) the utility or operations of one economic agent, A, include nonmonetary variables whose values are chosen by another economic agent, B, without regard to the effects on A, and (2) B does not pay A compensation equal to the incremental costs inflicted on A. Electricity generation involves a wide range of potential and actual environmental impacts. Legislative, permitting, and regulatory requirements directly or indirectly control certain environmental impacts, implicitly causing them to become internalized in the cost of electricity generation. Electricity generation, however, often produces residual environmental impacts that meet the definition of an externality. Mechanisms have been developed by several states to include the costs associated with externalities in the cost-effectiveness analyses of new powerplants. This paper examines these costs for solar thermal plants and applies two states' scoring methodologies to estimate how including externalities would affect the levelized costs of power from a solar plant in the Pacific Northwest. It concludes that including externalities in the economics can reduce the difference between the levelized cost of a coal and solar plant by between 0.74 and 2.42 cents/kWh.
Murphy, Kevin P; Crush, Lee; O'Malley, Eoin; Daly, Fergus E; O'Tuathaigh, Colm M P; O'Connor, Owen J; Cryan, John F; Maher, Michael M
2014-10-01
To examine the impact that anatomy-focused radiology teaching has on non-examined knowledge regarding radiation safety and radiology as a specialty. First-year undergraduate medical students completed surveys prior to and after undertaking the first-year anatomy programme that incorporates radiological anatomy. Students were asked opinions on preferred learning methodology and tested on understanding of radiology as a specialty and radiation safety. Pre-module and post-module response rates were 93 % (157/168) and 85 % (136/160), respectively. Pre-module and post-module, self-directed learning (SDL) ranked eighth (of 11) for preferred gross-anatomy teaching formats. Correct responses regarding radiologist/radiographer roles varied from 28-94 % on 16 questions with 4/16 significantly improving post-module. Identification of modalities that utilise radiation significantly improved for five of eight modalities post-module but knowledge regarding relative amount of modality-specific radiation use was variable pre-module and post-module. SDL is not favoured as an anatomy teaching method. Exposure of students to a radiological anatomy module delivered by senior clinical radiologists improved basic knowledge regarding ionising radiation use, but there was no improvement in knowledge regarding radiation exposure relative per modality. A possible explanation is that students recall knowledge imparted in didactic lectures but do little reading around the subject when the content is not examined. • Self-directed learning is not favoured as a gross anatomy teaching format amongst medical students. • An imaging anatomy-focused module improved basic knowledge regarding ionising radiation use. • Detailed knowledge of modality-specific radiation exposure remained suboptimal post-module. • Knowledge of roles within a clinical radiology department showed little change post-module.
Mora, Juan C; Baeza, Antonio; Robles, Beatriz; Sanz, Javier
2016-06-05
Naturally Occurring Radioactive Materials (NORM) wastes are generated in huge quantities in several industries and their management has been carried out under considerations of industrial non-radioactive wastes, before the concern on the radioactivity content was included in the legislation. Therefore these wastes were conditioned using conventional methods and the waste disposals were designed to isolate toxic elements from the environment for long periods of time. Spanish regulation for these conventional toxic waste disposals includes conditions that assure adequate isolation to minimize the impact of the wastes to the environment in present and future conditions. After 1996 the radiological impact of the management of NORM wastes is considered and all the aspects related with natural radiations and the radiological control regarding the management of residues from NORM industries were developed in the new regulation. One option to be assessed is the disposal of NORM wastes in hazardous and non-hazardous waste disposals, as was done before this new regulation. This work analyses the management of NORM wastes in these landfills to derive the masses that can be disposed without considerable radiological impact. Generic dose assessments were carried out under highly conservative hypothesis and a discussion on the uncertainty and variability sources was included to provide consistency to the calculations. Copyright © 2016 Elsevier B.V. All rights reserved.
Occupational external exposure to ionising radiation in France (2005-2011).
Feuardent, J; Scanff, P; Crescini, D; Rannou, A
2013-12-01
The Institute for Radiological Protection and Nuclear Safety (IRSN) produces the French annual report on occupational exposure to ionising radiation, collecting all national data and aggregating the results according to a unique activity classification expected to be shared by all involved in personal dosimetric monitoring (employers, external dosimetry services and IRSN). Nearly 344,000 monitored workers were counted in France in 2011, with a collective dose of 64.24 man.Sv. The average annual dose (as calculated over the number of measurably exposed workers) differed among the main activity fields: 0.54 mSv in medical and veterinary activities, 1.18 mSv in the nuclear field, 1.60 mSv in non-nuclear industry and 0.47 mSv in research activities. Because of improved knowledge about worker activities, the results for year 2011 are detailed per activity sectors in each field. Lasting limitations prevent from having complete and reliable worker activity information. Solutions are considered to reduce the inaccuracy in the annually published statistics. The evolution of occupational external exposure to ionising radiation from 2005 to 2011 in France is then presented for the main activity fields.
Radiological dose in Muria peninsula from SB-LOCA event
NASA Astrophysics Data System (ADS)
Sunarko; Suud, Zaki
2017-01-01
Dose assessment for accident condition is performed for Muria Peninsula region using source-term from Three-Mile Island unit 2 SB-LOCA accident. Xe-133, Kr-88, 1-131 and Cs-137 isotopes are considered in the calculation. The effluent is assumed to be released from a 50 m stack. Lagrangian particle dispersion method (LPDM) employing non-Gaussian dispersion coefficient in 3-dimensional mass-consistent wind-field is employed to obtain periodic surface-level concentration which is then time-integrated to obtain spatial distribution of ground-level dose. In 1-hour simulation, segmented plumes with 60 seconds duration with a total of 18.000 particles involved. Simulations using 6-hour worst-case meteorological data from Muria peninsula results in a peak external dose of around 1.668 mSv for low scenario and 6.892 mSv for high scenario in dry condition. In wet condition with 5 mm/hour and 10 mm/hour rain for the whole duration of the simulation provides only minor effect to dose. The peak external dose is below the regulatory limit of 50 mSv for effective skin dose from external gamma exposure.
Space shuttle phase B extension, volume 1
NASA Technical Reports Server (NTRS)
1971-01-01
In order to define a system which would significantly reduce payload delivery costs, activities were extended to modifications of the reusable space shuttle design concept. Considered were systems using orbiters with external propellant tanks and an interim expendable booster which allowed phased development of the usable orbiter and booster. Analyzed were: Merits of internal and external propellant tanks and the impact of external LH2 compared to L02 and LH2; impact of cargo bay size; impact abort; merit of expendable booster options; and merit of a phased development program. Studies showed that external L02/LH2 and the continued use of the J-2S engine on the orbiter reduced program cost and risk.
Alali, Abdullah E; Al-Shboul, Khaled F; Albdour, Samah A
2018-05-08
Natural radioactivity of common commercial marble and granite types used in Jordanian dwellings are measured using high-resolution gamma spectrometry. The activity concentrations of 226Ra, 232Th and 40K ranged from 8.57 ± 1.55 to 152.07 ± 3.26 Bq kg-1, 6.83 ± 1.25 to 365.43 ± 4.84 Bq kg-1 and 121.25 ± 9.10 to 1604.90 ± 31.28 Bq kg-1 in granite and from 0.53 ± 0.12 to 18.61 ± 1.60 Bq kg-1, 0.51 ± 0.19 to 4.87 ± 2.13 Bq kg-1 and 3.21 ± 0.96 to 58.09 ± 6.40 Bq kg-1 in marble, respectively. Various radiological hazard indices like gamma index, internal and external hazard indices and annual effective dose equivalent were calculated and compared with the international limits. Our results show that some granite types may pose a radiation hazard.
Entine, F; Bensimon Etzol, J; Bettencourt, C; Dondey, M; Michel, X; Gagna, G; Gellie, G; Corre, Y; Ugolin, N; Chevillard, S; Amabile, J-C
2018-07-01
Estimation of the dose received by accidentally irradiated victims is based on a tripod: clinical, biological, and physical dosimetry. The DosiKit system is an operational and mobile biodosimetry device allowing the measurement of external irradiation directly on the site of a radiological accident. This tool is based on capillary blood sample and hair follicle collection. The aim is to obtain a whole-body and local-surface dose assessment. This paper is about the technical evaluation of the DosiKit; the analytical process and scientific validation are briefly described. The Toulon exercise scenario was based on a major accident involving the reactor of a nuclear attack submarine. The design of the scenario made it impossible for several players (firefighters, medical team) to leave the area for a long time, and they were potentially exposed to high dose rates. The DosiKit system was fully integrated into a deployable radiological emergency laboratory, and the response to operational needs was very satisfactory.
[Practical implementation of a quality management system in a radiological department].
Huber, S; Zech, C J
2011-10-01
This article describes the architecture of a project aiming to implement a DIN EN ISO 9001 quality management system in a radiological department. It is intended to be a practical guide to demonstrate each step of the project leading to certification of the system. In a planning phase resources for the implementation of the project have to be identified and a quality management (QM) group as core team has to be formed. In the first project phase all available documents have to be checked and compiled in the QM manual. Moreover all relevant processes of the department have to be described in so-called process descriptions. In a second step responsibilities for the project are identified. Customer and employee surveys have to be carried out and a nonconformity management system has to be implemented. In this phase internal audits are also needed to check the new QM system, which is finally tested in the external certification audit with reference to its conformity with the standards.
Testing a Novel 3D Printed Radiographic Imaging Device for Use in Forensic Odontology.
Newcomb, Tara L; Bruhn, Ann M; Giles, Bridget; Garcia, Hector M; Diawara, Norou
2017-01-01
There are specific challenges related to forensic dental radiology and difficulties in aligning X-ray equipment to teeth of interest. Researchers used 3D printing to create a new device, the combined holding and aiming device (CHAD), to address the positioning limitations of current dental X-ray devices. Participants (N = 24) used the CHAD, soft dental wax, and a modified external aiming device (MEAD) to determine device preference, radiographer's efficiency, and technique errors. Each participant exposed six X-rays per device for a total of 432 X-rays scored. A significant difference was found at the 0.05 level between the three devices (p = 0.0015), with the MEAD having the least amount of total errors and soft dental wax taking the least amount of time. Total errors were highest when participants used soft dental wax-both the MEAD and the CHAD performed best overall. Further research in forensic dental radiology and use of holding devices is needed. © 2016 American Academy of Forensic Sciences.
"EcoRadiology"--pulling the plug on wasted energy in the radiology department.
McCarthy, Colin J; Gerstenmaier, Jan F; O' Neill, Ailbhe C; McEvoy, Sinead H; Hegarty, Chris; Heffernan, Eric J
2014-12-01
We sought to evaluate the power consumption of various devices around the radiology department, audit our use of recycling, and review efforts by vendors to reduce the environmental impact of their products. Using a readily available power monitor, we calculated the power consumption of different devices around our department. In particular, we calculated the financial and environmental cost of leaving equipment on overnight and/or at weekends. When it was not possible to measure energy usage directly, we obtained and reviewed relevant technical manuals. We contacted vendors directly to document how the environmental impact of new technology and decommissioning aging technology is being tackled. We found that 29 of 43 desktop computers and 25 of 27 picture archiving and communications system (PACS) reporting stations were left on needlessly overnight and/or at weekends, resulting in estimated electrical running costs while not in use of approximately $7253 per year, and CO2 emissions equivalent to the annual emissions of over 10 passenger cars. We discovered that none of our PACS reporting stations supported energy-saving modes such as "sleep" or "hibernate." Despite encouraging staff to turn off computers when not in use, a reaudit found no improvement in results. Simple steps such as turning off computers and air-conditioning units can produce very significant financial and environmental savings. Radiology can lead the way in making hospitals more energy efficient. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Estimates of radiological risk from depleted uranium weapons in war scenarios.
Durante, Marco; Pugliese, Mariagabriella
2002-01-01
Several weapons used during the recent conflict in Yugoslavia contain depleted uranium, including missiles and armor-piercing incendiary rounds. Health concern is related to the use of these weapons, because of the heavy-metal toxicity and radioactivity of uranium. Although chemical toxicity is considered the more important source of health risk related to uranium, radiation exposure has been allegedly related to cancers among veterans of the Balkan conflict, and uranium munitions are a possible source of contamination in the environment. Actual measurements of radioactive contamination are needed to assess the risk. In this paper, a computer simulation is proposed to estimate radiological risk related to different exposure scenarios. Dose caused by inhalation of radioactive aerosols and ground contamination induced by Tomahawk missile impact are simulated using a Gaussian plume model (HOTSPOT code). Environmental contamination and committed dose to the population resident in contaminated areas are predicted by a food-web model (RESRAD code). Small values of committed effective dose equivalent appear to be associated with missile impacts (50-y CEDE < 5 mSv), or population exposure by water-independent pathways (50-y CEDE < 80 mSv). The greatest hazard is related to the water contamination in conditions of effective leaching of uranium in the groundwater (50-y CEDE < 400 mSv). Even in this worst case scenario, the chemical toxicity largely predominates over radiological risk. These computer simulations suggest that little radiological risk is associated to the use of depleted uranium weapons.
ERIC Educational Resources Information Center
An, Lu; Qiu, Junping
2004-01-01
Journal impact factors (JIFs) as determined by the Institute for Scientific and Technological Information of China (ISTIC) of forty-two Chinese engineering journals were compared with external Web link counts, obtained from Lycos, and Web Impact Factors (WIFs) of corresponding journal Web sites to determine if any significant correlation existed…
Valuing environmental health for informed policy-making.
Máca, Vojtěch; Melichar, Jan; Ščasný, Milan; Kohlová, Markéta Braun
2017-03-01
Monetized environmental health impact assessments help to better evaluate the environmental burden of a wide range of economic activities. Apart from the limitations and uncertainties in physical and biological science used in such assessments, assumptions taken from economic valuation may also substantially influence subsequent policy-making considerations. This study attempts to demonstrate the impact of normative policy assumptions on quantified external costs using a case study of recently discussed variants of future coal mining and use of extracted coal in electricity and heat generation in the Czech Republic. A bottom-up impact-pathway approach is used for quantification of external costs. Several policy perspectives are elaborated for aggregating impacts that differ in geographic coverage and in how valuation of quantified impacts is adjusted in a particular perspective. We find that the fraction of monetized external impacts taken into policy-making considerations may vary according to choice of decision perspective up to a factor of 10. At present there are virtually no hard rules for defining geographical boundaries or adjusting values for a summation of monetized environmental impacts. We, however, stress that any rigorous external cost assessment should, for instance in a separate calculation, take account of impacts occurring beyond country borders.
Radioactivity impacts of the Fukushima Nuclear Accident on the atmosphere
NASA Astrophysics Data System (ADS)
Lin, W.; Chen, L.; Yu, W.; Ma, H.; Zeng, Z.; Lin, J.; Zeng, S.
2015-02-01
The Fukushima Nuclear Accident (FNA) resulted in a large amount of radionuclides released into the atmosphere and dispersed globally, which has greatly raised public concerns. The state of the art for source terms of 19 kinds of radionuclides derived from the FNA was comprehensively collected and compared with levels of the global fallout and the Chernobyl Nuclear Accident (CNA). The atmospheric impacts of the FNA were evaluated from three aspects including radioactive baseline of the atmosphere, the concentration limits in standards and radiological protection. The FNA should not impose significant radiological risk on the public members in the countries excluding Japan. A conceptual scheme of Fukushima-derived radionuclides with physical and physicochemical insights on different temporal-spatial timescales was discussed and illustrated to understand their fates in the atmosphere.
Weld Repair of a Stamped Pressure Vessel in a Radiologically Controlled Zone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cannell, Gary L.; Huth, Ralph J.; Hallum, Randall T.
2013-08-26
In September 2012 an ASME B&PVC Section VIII stamped pressure vessel located at the DOE Hanford Site Effluent Treatment Facility (ETF) developed a through-wall leak. The vessel, a steam/brine heat exchanger, operated in a radiologically controlled zone (by the CH2MHill PRC or CHPRC), had been in service for approximately 17 years. The heat exchanger is part of a single train evaporator process and its failure caused the entire system to be shut down, significantly impacting facility operations. This paper describes the activities associated with failure characterization, technical decision making/planning for repair by welding, logistical challenges associated with performing work inmore » a radiologically controlled zone, performing the repair, and administrative considerations related to ASME code requirements.« less
Beresford, Nicholas A; Copplestone, David
2011-07-01
The recent events at the Fukushima Daiichi nuclear power plant in Japan have raised questions over the effects of radiation in the environment. This article considers what we have learned about the radiological consequences for the environment from the Chernobyl accident, Ukraine, in April 1986. The literature offers mixed opinions of the long-term impacts on wildlife close to the Chernobyl plant, with some articles reporting significant effects at very low dose rates (below natural background dose rate levels in, for example, the United Kingdom). The lack of agreement highlights the need for further research to establish whether current radiological protection criteria for wildlife are adequate (and to determine if there are any implications for human radiological protection). Copyright © 2011 SETAC.
Most Common Publication Types in Radiology Journals:: What is the Level of Evidence?
Rosenkrantz, Andrew B; Pinnamaneni, Niveditha; Babb, James S; Doshi, Ankur M
2016-05-01
This study aimed to assess the most common publication types in radiology journals, as well as temporal trends and association with citation frequency. PubMed was searched to extract all published articles having the following "Publication Type" indices: "validation studies," "meta-analysis," "clinical trial," "comparative study," "evaluation study," "guideline," "multicenter study," "randomized study," "review," "editorial," "case report," and "technical report." The percentage of articles within each category published within clinical radiology journals was computed. Normalized percentages for each category were also computed on an annual basis. Citation counts within a 2-year window following publication were obtained using Web of Science. Overall trends were assessed. Publication types with the highest fraction in radiology journals were technical reports, evaluation studies, and case reports (4.8% to 5.8%). Publication types with the lowest fraction in radiology journals were randomized trials, multicenter studies, and meta-analyses (0.8% to 1.5%). Case reports showed a significant decrease since 1999, with accelerating decline since 2007 (P = 0.002). Publication types with highest citation counts were meta-analyses, guidelines, and multicenter studies (8.1 ± 10.7 to 12.9 ± 5.1). Publication types with lowest citation counts were case reports, editorials, and technical reports (1.4 ± 2.4 to 2.9 ± 4.3). The representation in radiology journals and citation frequency of the publication types showed weak inverse correlation (r = -0.372). Radiology journals have historically had relatively greater representation of less frequently cited publication types. Various strategies, including methodological training, multidisciplinary collaboration, national support networks, as well as encouragement of higher level of evidence by funding agencies and radiology journals themselves, are warranted to improve the impact of radiological research. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Cruz Ciria, S; Jiménez Aragón, F; García Mur, C; Esteban Cuesta, H; Gros Bañeres, B
2014-01-01
To evaluate the radiologic and pathologic responses to neoadjuvant chemotherapy and their correlation in the molecular subtypes of breast cancer and to analyze their impact in disease-free survival. We included 205 patients with breast cancer treated with neoadjuvant chemotherapy. We evaluated the radiologic response by comparing MRI images acquired before and after chemotherapy. The pathologic response was classified on the Miller and Payne scale. For each subtype (HER2+, TN, luminal A, luminal B HER2-, and luminal B HER2+), we used the χ(2) test, Student's t-test, ANOVA, and Kendall's Tau-b to evaluate the radiologic response and the pathologic response, the radiologic-pathologic correlation, and the disease-free survival. The subtypes HER2+ (62.1%) and TN (45.2%) had higher rates of complete radiologic response. The pathologic response was 65.5% in the HER2+ subtype, 38.1% in the TN subtype, 2.6% in the luminal A subtype, 8.2% in the luminal B HER2- subtype, and 31% in the luminal B HER2+ subtype. The rate of radiologic-pathologic correlation was significant in all subtypes, higher in TN and HER2 (Tau-b coefficients 0.805 and 0.717, respectively). Disease-free survival was higher in HER2+ (91.9±3.3 months) and lower in TN (69.5±6.3 months), with significant differences between the cases with poor and good radiologic responses (P=.040). Survival was greater in cases with good radiologic response, except in cases with luminal A subtype. MRI can be a useful tool that provides information about the evolution of breast cancer treated with neoadjuvant chemotherapy, which varies with the immunohistochemical subtype. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.
10 CFR 150.31 - Requirements for Agreement State regulation of byproduct material.
Code of Federal Regulations, 2014 CFR
2014-01-01
... include: (A) An assessment of the radiological and nonradiological impacts to the public health of the activities to be conducted pursuant to such licenses; (B) An assessment of any impact on any waterway and... Agreement State for the protection of the public health, safety, and the environment from hazards associated...
10 CFR 150.31 - Requirements for Agreement State regulation of byproduct material.
Code of Federal Regulations, 2010 CFR
2010-01-01
... include: (A) An assessment of the radiological and nonradiological impacts to the public health of the activities to be conducted pursuant to such licenses; (B) An assessment of any impact on any waterway and... Agreement State for the protection of the public health, safety, and the environment from hazards associated...
10 CFR 150.31 - Requirements for Agreement State regulation of byproduct material.
Code of Federal Regulations, 2013 CFR
2013-01-01
... include: (A) An assessment of the radiological and nonradiological impacts to the public health of the activities to be conducted pursuant to such licenses; (B) An assessment of any impact on any waterway and... Agreement State for the protection of the public health, safety, and the environment from hazards associated...
10 CFR 150.31 - Requirements for Agreement State regulation of byproduct material.
Code of Federal Regulations, 2012 CFR
2012-01-01
... include: (A) An assessment of the radiological and nonradiological impacts to the public health of the activities to be conducted pursuant to such licenses; (B) An assessment of any impact on any waterway and... Agreement State for the protection of the public health, safety, and the environment from hazards associated...
Gordeev, Konstantin; Shinkarev, Sergey; Ilyin, Leonid; Bouville, André; Hoshi, Masaharu; Luckyanov, Nickolas; Simon, Steven L
2006-02-01
A short analysis of all 111 atmospheric events conducted at the Semipalatinsk Test Site (STS) in 1949-1962 with regard to significant off-site exposure (more than 5 mSv of the effective dose during the first year after the explosion) has been made. The analytical method used to assess external exposure to the residents living in settlements near the STS is described. This method makes use of the archival data on the radiological conditions, including the measurements of exposure rate. Special attention was given to the residents of Dolon and Kanonerka villages exposed mainly as a result of the first test, detonated on August 29, 1949. For the residents of those settlements born in 1935, the dose estimates calculated according to the analytical method, are compared to those derived from the thermoluminescence measurements in bricks and electron paramagnetic resonance measurements in teeth. The methods described in this paper were used for external dose assessment for the cohort members at an initial stage of an ongoing epidemiological study conducted by the U.S. National Cancer Institute in the Republic of Kazakhstan. Recently revised methods and estimates of external exposure for that cohort are given in another paper (Simon et al.) in this conference.
Final Environmental Impact Statement (EIS) for the Space Nuclear Thermal Propulsion (SNTP) program
NASA Astrophysics Data System (ADS)
1991-09-01
A program has been proposed to develop the technology and demonstrate the feasibility of a high-temperature particle bed reactor (PBR) propulsion system to be used to power an advanced second stage nuclear rocket engine. The purpose of this Final Environmental Impact Statement (FEIS) is to assess the potential environmental impacts of component development and testing, construction of ground test facilities, and ground testing. Major issues and goals of the program include the achievement and control of predicted nuclear power levels; the development of materials that can withstand the extremely high operating temperatures and hydrogen flow environments; and the reliable control of cryogenic hydrogen and hot gaseous hydrogen propellant. The testing process is designed to minimize radiation exposure to the environment. Environmental impact and mitigation planning are included for the following areas of concern: (1) Population and economy; (2) Land use and infrastructure; (3) Noise; (4) Cultural resources; (5) Safety (non-nuclear); (6) Waste; (7) Topography; (8) Geology; (9) Seismic activity; (10) Water resources; (11) Meteorology/Air quality; (12) Biological resources; (13) Radiological normal operations; (14) Radiological accidents; (15) Soils; and (16) Wildlife habitats.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Want, J.; Merry-Libby, P.
1985-10-29
Americium-241 is widely used as a radiation source, but it also has some potential risk if taken into the body because of its high dose conversion factor. Although the radiotoxicity of americium-241 is small compared to other transuranic actinides, its effects on the reproductive system and on development of the placenta are more damaging than the effects of plutonium-239. In Ohio, a gemologist's laboratory was contaminated with americium-241. Prior to decontamination of the laboratory, potential radiological impacts to the surrounding environment were assessed. A hypothetical fire accident resulting in a unit release (1 curie) was assumed. Potential radiological impacts weremore » simulated using an atmospheric dispersion and dosimetry model with local meteorological data, population census data, and detailed information regarding the neighborhood. The results indicate that there could have been a significant impact on nearby residents from americium-241 via atmospheric dispersion if a major catastrophic release had occurred prior to contamination and decommissioning of the laboratory. 14 refs., 3 figs., 2 tabs.« less
A comparison of personal dose equivalent measurements made by personal dosemeters
NASA Astrophysics Data System (ADS)
Cechak, T.; Davidkova, J.; Kodl, O.; Novacek, P.; Papirnik, P.; Petrova, K.; Prasek, P.; Martincik, J.; Sochor, V.
2014-11-01
Individual monitoring services for external radiation were tested in the Czech Republic. The results of the tests show that they are dosimetry systems authorized and regularly tested in the Czech Republic having outliers for low energy region and angle of 50 degree and greater. With the highest probability, it can be stated that the processing equipment does not determine the angle of exposure reliably. These cases may have caused overestimations of Hp(10) in the special conditions occurring e.g. in interventional radiology and cardiology procedures.
External dose assessment in the Ukraine following the Chernobyl accident
NASA Astrophysics Data System (ADS)
Frazier, Remi Jordan Lesartre
While the physiological effects of radiation exposure have been well characterized in general, it remains unclear what the relationship is between large-scale radiological events and psychosocial behavior outcomes in individuals or populations. To investigate this, the National Science Foundation funded a research project in 2008 at the University of Colorado in collaboration with Colorado State University to expand the knowledge of complex interactions between radiation exposure, perception of risk, and psychosocial behavior outcomes by modeling outcomes for a representative sample of the population of the Ukraine which had been exposed to radiocontaminant materials released by the reactor accident at Chernobyl on 26 April 1986. In service of this project, a methodology (based substantially on previously published models specific to the Chernobyl disaster and the Ukrainian population) was developed for daily cumulative effective external dose and dose rate assessment for individuals in the Ukraine for as a result of the Chernobyl disaster. A software platform was designed and produced to estimate effective external dose and dose rate for individuals based on their age, occupation, and location of residence on each day between 26 April 1986 and 31 December 2009. A methodology was developed to transform published 137Cs soil deposition contour maps from the Comprehensive Atlas of Caesium Deposition on Europe after the Chernobyl Accident into a geospatial database to access these data as a radiological source term. Cumulative effective external dose and dose rate were computed for each individual in a 703-member cohort of Ukrainians randomly selected to be representative of the population of the country as a whole. Error was estimated for the resulting individual dose and dose rate values with Monte Carlo simulations. Distributions of input parameters for the dose assessment methodology were compared to computed dose and dose rate estimates to determine which parameters were driving the computed results. The mean external effective dose for all individuals in the cohort due to exposure to radiocontamination from the Chernobyl accident between 26 April 1986 and 31 December 2009 was found to be 1.2 mSv; the geometric mean was 0.84 mSv with a geometric standard deviation of 2.1. The mean value is well below the mean external effective dose expected due to typical background radiation (which in the United States over this time period would be 12.0 mSv). Sensitivity analysis suggests that the greatest driver of the distribution of individual dose estimates is lack of specific information about the daily behavior of each individual, specifically the portion of time each individual spent indoors (and shielded from radionuclides deposited on the soil) versus outdoors (and unshielded).
Transportation of radionuclides in urban environs: draft environmental assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finley, N.C.; Aldrich, D.C.; Daniel, S.L.
1980-07-01
This report assesses the environmental consequences of the transportation of radioactive materials in densely populated urban areas, including estimates of the radiological, nonradiological, and social impacts arising from this process. The chapters of the report and the appendices which follow detail the methodology and results for each of four causative event categories: incident free transport, vehicular accidents, human errors or deviations from accepted quality assurance practices, and sabotage or malevolent acts. The numerical results are expressed in terms of the expected radiological and economic impacts from each. Following these discussions, alternatives to the current transport practice are considered. Then, themore » detailed analysis is extended from a limited area of New York city to other urban areas. The appendices contain the data bases and specific models used to evaluate these impacts, as well as discussions of chemical toxicity and the social impacts of radioactive material transport in urban areas. The latter are evaluated for each causative event category in terms of psychological, sociological, political, legal, and organizational impacts. The report is followed by an extensive bibliography covering the many fields of study which were required in performing the analysis.« less
Induced activation studies for the LHC upgrade to High Luminosity LHC
NASA Astrophysics Data System (ADS)
Adorisio, C.; Roesler, S.
2018-06-01
The Large Hadron Collider (LHC) will be upgraded in 2019/2020 to increase its luminosity (rate of collisions) by a factor of five beyond its design value and the integrated luminosity by a factor ten, in order to maintain scientific progress and exploit its full capacity. The novel machine configuration, called High Luminosity LHC (HL-LHC), will increase consequently the level of activation of its components. The evaluation of the radiological impact of the HL-LHC operation in the Long Straight Sections of the Insertion Region 1 (ATLAS) and Insertion Region 5 (CMS) is presented. Using the Monte Carlo code FLUKA, ambient dose equivalent rate estimations have been performed on the basis of two announced operating scenarios and using the latest available machine layout. The HL-LHC project requires new technical infrastructure with caverns and 300 m long tunnels along the Insertion Regions 1 and 5. The new underground service galleries will be accessible during the operation of the accelerator machine. The radiological risk assessment for the Civil Engineering work foreseen to start excavating the new galleries in the next LHC Long Shutdown and the radiological impact of the machine operation will be discussed.
Assessment of the radiological impact of oil refining industry.
Bakr, W F
2010-03-01
The field of radiation protection and corresponding national and international regulations has evolved to ensure safety in the use of radioactive materials. Oil and gas production processing operations have been known to cause naturally occurring radioactive materials (NORMs) to accumulate at elevated concentrations as by-product waste streams. A comprehensive radiological study on the oil refining industry in Egypt was carried out to assess the radiological impact of this industry on the workers. Scales, sludge, water and crude oil samples were collected at each stage of the refining process. The activity concentration of (226)Ra, (232)Th and (40)K were determined using high-resolution gamma spectrometry. The average activity concentrations of the determined isotopes are lower than the IAEA exempt activity levels for NORM isotopes. Different exposure scenarios were studied. The average annual effective dose for workers due to direct exposure to gamma radiation and dust inhalation found to be 0.6 microSv and 3.2 mSv, respectively. Based on the ALARA principle, the results indicate that special care must be taken during cleaning operations in order to reduce the personnel's exposure due to maintenance as well as to avoid contamination of the environment. 2009 Elsevier Ltd. All rights reserved.
State of the art of palliative therapy.
Seregni, E; Padovano, B; Coliva, A; Zecca, E; Bombardieri, E
2011-08-01
Bone pain in advanced stages of cancer significantly decreases the patient's quality of life having a great impact on physical, physiological and social functioning. About 65% of patients with prostate or breast cancer will experience symptomatic skeletal metastases. Bone pain sustained by osseous metastases represents the most frequent kind of pain and its clinical presentation and characteristics differ from other type of neoplastic pain (i.e., neuropathic or visceral ones). Pathophysiology of bone pain is not yet completely understood but a general mechanism including infiltration of bone tissue associated with osteolysis and release of biological active molecules able to stimulate peripheral nervous terminals, seems to be principally involved. In oncological practice, painful skeletal metastases are managed by different multidisciplinary modalities which include the use of systemic analgesics (i.e., bisphosphonates), antineoplastic agents (i.e., hormones and chemotherapeutics), external beam radiotherapy, interventional radiology and radiopharmaceuticals. In this review we will discuss the state of the art of palliative therapy of bone pain with particular emphasis to the current approved radiopharmaceuticals, focusing on indications, patient selection, efficacy and toxicity. Some remarks on new or under developing strategies in systemic metabolic radiopharmaceutical therapy will be reported.
External foam layers to football helmets reduce head impact severity.
Nakatsuka, Austin S; Yamamoto, Loren G
2014-08-01
Current American football helmet design has a rigid exterior with a padded interior. Softening the hard external layer of the helmet may reduce the impact potential of the helmet, providing extra head protection and reducing its use as an offensive device. The objective of this study is to measure the impact reduction potential provided by external foam. We obtained a football helmet with built-in accelerometer-based sensors, placed it on a boxing mannequin and struck it with a weighted swinging pendulum helmet to mimic the forces sustained during a helmet-to-helmet strike. We then applied layers of 1.3 cm thick polyolefin foam to the exterior surface of the helmets and repeated the process. All impact severity measures were significantly reduced with the application of the external foam. These results support the hypothesis that adding a soft exterior layer reduces the force of impact which may be applicable to the football field. Redesigning football helmets could reduce the injury potential of the sport.
External Foam Layers to Football Helmets Reduce Head Impact Severity
Nakatsuka, Austin S
2014-01-01
Current American football helmet design has a rigid exterior with a padded interior. Softening the hard external layer of the helmet may reduce the impact potential of the helmet, providing extra head protection and reducing its use as an offensive device. The objective of this study is to measure the impact reduction potential provided by external foam. We obtained a football helmet with built-in accelerometer-based sensors, placed it on a boxing mannequin and struck it with a weighted swinging pendulum helmet to mimic the forces sustained during a helmet-to-helmet strike. We then applied layers of 1.3 cm thick polyolefin foam to the exterior surface of the helmets and repeated the process. All impact severity measures were significantly reduced with the application of the external foam. These results support the hypothesis that adding a soft exterior layer reduces the force of impact which may be applicable to the football field. Redesigning football helmets could reduce the injury potential of the sport. PMID:25157327
ERIC Educational Resources Information Center
Stensaker, Bjørn; Leiber, Theodor
2015-01-01
The aim of the article is to provide a framework in which the organisational impact of external quality assurance (EQA) can be assessed. Based on existing studies of the impact of EQA in universities and colleges it is suggested that greater systematisation of how impact is measured is needed for a better understanding of how EQA can be used as a…
Yeoh, David; Goddard, Richard; Macnamara, Paul; Bowman, Nicholas; Miles, Kim; East, Debra; Butler-Manuel, Adrian
2008-08-01
The most common indication for knee arthrodesis is pain and instability in an unreconstructable knee following an infected knee arthroplasty. In this study, we compare the use of the Mayday arthrodesis nail (Orthodynamics, Christchurch, UK) versus external fixation, Orthofix (Berkshire UK) and Stryker Hoffman II (County Cork, Ireland). All patients in this study underwent arthrodesis between 1995 and 2006 at Conquest Hospital, Hastings. In group A, 11 patients underwent arthrodesis with a Mayday nail. In all cases, the indications were infected total knee replacements (TKR). Three of these patients previously had failed attempts at arthrodesis with external fixation devices. In group B, seven patients underwent arthrodesis using external fixation. In six patients, the indication was infected TKRs. Results were reviewed retrospectively, with union assessed both clinically and radiologically. The mean inpatient stay for the Mayday nail group was 23 days (range 8-45 days) compared with 76 days (range 34-122) for the external fixation group (p<0.01, CI 95). Ten patients in group A went on to confirmed primary arthrodesis. One patient underwent revision arthrodesis with a Mayday nail and subsequently united. In group B only two patients achieved union. The rate of union was significantly greater in the Mayday nail group than the external fixation group (91% vs 29%, p<0.01). Of those patients that achieved union, there was no difference in the time to fusion between groups. Our study supported the existing literature and found that the Mayday nail appeared more effective than monoaxial external fixators for arthrodesis in the management of infected total knee replacements.
Manet, Romain; Payen, Jean-François; Guerin, Romain; Martinez, Orianne; Hautefeuille, Serge; Francony, Gilles; Gergelé, Laurent
2017-10-01
Despite various treatments to control intracranial pressure (ICP) after brain injury, patients may present a late onset of high ICP or a poor response to medications. External lumbar drainage (ELD) can be considered a therapeutic option if high ICP is due to communicating external hydrocephalus. We aimed at describing the efficacy and safety of ELD used in a cohort of traumatic or non-traumatic brain-injured patients. In this multicentre retrospective analysis, patients had a delayed onset of high ICP after the initial injury and/or a poor response to ICP treatments. ELD was considered in the presence of radiological signs of communicating external hydrocephalus. Changes in ICP values and side effects following the ELD procedure were reported. Thirty-three patients with a median age of 51 years (25-75th percentile: 34-61 years) were admitted after traumatic (n = 22) or non-traumatic (n = 11) brain injuries. Their initial Glasgow Coma Scale score was 8 (4-11). Eight patients underwent external ventricular drainage prior to ELD. Median time to ELD insertion was 5 days (4-8) after brain insult. In all patients, ELD was dramatically effective in lowering ICP: 25 mmHg (20-31) before versus 7 mmHg (3-10) after (p < 0.001). None of the patients showed adverse effects such as pupil changes or intracranial bleeding after the procedure. One patient developed an ELD-related infection. These findings indicate that ELD may be considered potentially effective in controlling ICP, remaining safe if a firm diagnosis of communicating external hydrocephalus has been made.
Yin, Hao; Pizzol, Massimo; Xu, Linyu
2017-07-01
Some cities in China are facing serious air pollution problems including high concentrations of particles, SO 2 and NO x . Exposure to PM2.5, one of the primary air pollutants in many cities in China, is highly correlated with various adverse health impacts and ultimately represents a cost for society. The aim of this study is to assess health impacts and external costs related to PM2.5 pollution in Beijing, China with different baseline concentrations and valuation methods. The idea is to provide a reasonable estimate of the total health impacts and external cost due to PM2.5 pollution, as well as a quantification of the relevant uncertainty. PM2.5 concentrations were retrieved for the entire 2012 period in 16 districts of Beijing. The various PM2.5 related health impacts were identified and classified to avoid double counting. Exposure-response coefficients were then obtained from literature. Both the value of statistical life (VSL) and the amended human capital (AHC) approach were applied for external costs estimation, which could provide the upper and lower bound of the external costs due to PM2.5. To fully understand the uncertainty levels, the external cost distribution was determined via Monte Carlo simulation based on the uncertainty of the parameters such as PM2.5 concentration, exposure-response coefficients, and economic cost per case. The results showed that the external costs were equivalent to around 0.3% (AHC, China's guideline: C 0 = 35 μg/m 3 ) to 0.9% (VSL, WHO guideline: C 0 = 10 μg/m 3 ) of regional GDP depending on the valuation method and on the assumed baseline PM2.5 concentration (C 0 ). Among all the health impacts, the economic loss due to premature deaths accounted for more than 80% of the overall external costs. The results of this study could help policymakers prioritizing the PM2.5 pollution control interventions and internalize the external costs through the application of economic policy instruments. Copyright © 2017 Elsevier Ltd. All rights reserved.
Real view radiology-impact on search patterns and confidence in radiology education.
Bailey, Jared H; Roth, Trenton D; Kohli, Mark D; Heitkamp, Darel E
2014-07-01
Search patterns are important for radiologists because they enable systematic case review. Because radiology residents are exposed to so many imaging modalities and anatomic regions, and they rotate on-and-off service so frequently, they may have difficulty establishing effective search patterns. We developed Real View Radiology (RVR), an educational system founded on guided magnetic resonance imaging (MRI) case review and evaluated its impact on search patterns and interpretative confidence of junior radiology residents. RVR guides learners through unknown examinations by sequentially prompting learners to certain aspects of a case via a comprehensive question set and then providing immediate feedback. Junior residents first completed a brief evaluation regarding their level of confidence when interpreting certain joint MRI cases and frequency of search pattern use. They spent four half-days interpreting cases using RVR. Once finished, they repeated the evaluations. The junior resident results were compared to third-year residents who had not used RVR. The data were analyzed for change in confidence, use of search patterns, and number of cases completed. Twelve first-year and thirteen second-year residents (trained cohort) were enrolled in the study. During their 4-week musculoskeletal rotations, they completed on average 29.3 MRI knee (standard deviation [SD], 1.6) and 17.4 shoulder (SD, 1.2) cases using RVR. Overall search pattern scores of the trained cohort increased significantly both from pretraining to posttraining (knee P < .01, shoulder P < .01) and compared to the untrained third-year residents (knee (P < .01, and shoulder P < .01). The trained cohort confidence scores also increased significantly from pre to post for all joints (knee P < .01, shoulder P < .01, pelvis P < .01, and ankle P < .01). Radiology residents can increase their MRI case interpretation confidence and improve the consistency of search pattern use by training with a question-based sequential reveal educational program. RVR could be used to supplement training and assist with search pattern creation in areas in which residents often do not acquire adequate clinical exposure. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Contribution of internal exposures to the radiological consequences of the Chernobyl accident.
Balonov, M I; Anspaugh, L R; Bouville, A; Likhtarev, I A
2007-01-01
The main pathways leading to exposure of members of the general public due to the Chernobyl accident were external exposure from radionuclides deposited on the ground and ingestion of contaminated terrestrial food products. The collective dose to the thyroid was nearly 1.5 million man Gy in Belarus, Russia and Ukraine with nearly half received by children and adolescents. The collective effective dose received in 1986-2005 by approximately five million residents living in the affected areas of the three countries was approximately 50,000 man Sv with approximately 40% from ingestion. That contribution might have been larger if countermeasures had not been applied. The main radionuclide contributing to both external and internal effective dose is 137Cs with smaller contributions of 134Cs and 90Sr and negligible contribution of transuranic elements. The major demonstrated radiation-caused health effect of the Chernobyl accident has been an elevated incidence of thyroid cancer in children.
Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers
NASA Astrophysics Data System (ADS)
Berbeco, Ross I.; Mostafavi, Hassan; Sharp, Gregory C.; Jiang, Steve B.
2005-10-01
Due to the risk of pneumothorax, many clinicians are reluctant to implant radiopaque markers within patients' lungs for the purpose of radiographic or fluoroscopic tumour localization. We propose a method of gated therapy using fluoroscopic information without the implantation of radiopaque markers. The method presented here does not rely on any external motion signal either. Breathing phase information is found by analysing the fluoroscopic intensity fluctuations in the lung. As the lungs fill/empty, the radiological pathlength through them shortens/lengthens, giving brighter/darker fluoroscopic intensities. The phase information is combined with motion-enhanced template matching to turn the beam on when the tumour is in the desired location. A study based on patient data is presented to demonstrate the feasibility of this procedure. The resulting beam-on pattern is similar to that produced by an external gating system. The only discrepancies occur briefly and at the gate edges.
NASA Astrophysics Data System (ADS)
Akahane, Keiichi; Yonai, Shunsuke; Fukuda, Shigekazu; Miyahara, Nobuyuki; Yasuda, Hiroshi; Iwaoka, Kazuki; Matsumoto, Masaki; Fukumura, Akifumi; Akashi, Makoto
2013-04-01
The great east Japan earthquake and subsequent tsunamis caused Fukushima Dai-ichi Nuclear Power Plant (NPP) accident. National Institute of Radiological Sciences (NIRS) developed the external dose estimation system for Fukushima residents. The system is being used in the Fukushima health management survey. The doses can be obtained by superimposing the behavior data of the residents on the dose rate maps. For grasping the doses, 18 evacuation patterns of the residents were assumed by considering the actual evacuation information before using the survey data. The doses of the residents from the deliberate evacuation area were relatively higher than those from the area within 20 km radius. The estimated doses varied from around 1 to 6 mSv for the residents evacuated from the representative places in the deliberate evacuation area. The maximum dose in 18 evacuation patterns was estimated to be 19 mSv.
Akahane, Keiichi; Yonai, Shunsuke; Fukuda, Shigekazu; Miyahara, Nobuyuki; Yasuda, Hiroshi; Iwaoka, Kazuki; Matsumoto, Masaki; Fukumura, Akifumi; Akashi, Makoto
2013-01-01
The great east Japan earthquake and subsequent tsunamis caused Fukushima Dai-ichi Nuclear Power Plant (NPP) accident. National Institute of Radiological Sciences (NIRS) developed the external dose estimation system for Fukushima residents. The system is being used in the Fukushima health management survey. The doses can be obtained by superimposing the behavior data of the residents on the dose rate maps. For grasping the doses, 18 evacuation patterns of the residents were assumed by considering the actual evacuation information before using the survey data. The doses of the residents from the deliberate evacuation area were relatively higher than those from the area within 20 km radius. The estimated doses varied from around 1 to 6 mSv for the residents evacuated from the representative places in the deliberate evacuation area. The maximum dose in 18 evacuation patterns was estimated to be 19 mSv.
Bohl, Michael A; Goswami, Roopa; Strassner, Brett; Stanger, Paula
2016-08-01
The purpose of this investigation was to evaluate the potential of using the ACR's Dose Index Registry(®) to meet The Joint Commission's requirements to identify incidents in which the radiation dose index from diagnostic CT examinations exceeded the protocol's expected dose index range. In total, 10,970 records in the Dose Index Registry were statistically analyzed to establish both an upper and lower expected dose index for each protocol. All 2015 studies to date were then retrospectively reviewed to identify examinations whose total examination dose index exceeded the protocol's defined upper threshold. Each dose incident was then logged and reviewed per the new Joint Commission requirements. Facilities may leverage their participation in the ACR's Dose Index Registry to fully meet The Joint Commission's dose incident identification review and external benchmarking requirements. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Understanding patient satisfaction ratings for radiology services.
Lang, Elvira V; Yuh, William T C; Ajam, Amna; Kelly, Ronda; Macadam, Luke; Potts, Richard; Mayr, Nina A
2013-12-01
Under the Hospital Value-Based Purchasing Program of the Centers for Medicare & Medicaid Services, patient satisfaction accounts for 30% of the measures of and payments for quality of care. Understanding what drives patient satisfaction data and how the data are obtained, converted into scores, and formulated into rankings is increasingly critical for imaging departments. The objectives of this article are to describe the potential impact of patient satisfaction ratings on institutions and individuals, explain how patient satisfaction is rated and ranked, identify drivers that affect the ratings and rankings, and probe the resulting challenges unique to radiology departments. Research results indicate that training providers to make simple modifications in their language and behavior during patient care can significantly impact patient satisfaction, which, in turn, can impact both quality-of-care ratings and the bottom line of hospitals. Training providers is a simple and cost-effective way to potentiate the clinical expression of compassion into improvement of patient satisfaction and financial reward, a national trend that no one in the game can afford to ignore.
Effective radiology dashboards: key research findings.
Karami, Mahtab; Safdari, Reza; Rahimi, Azin
2013-01-01
Innovative organizations have access to information for business intelligence through the objectives displayed in dashboards. In healthcare organizations, where the goal is to improve quality of care along with reducing costs, the radiology department is important from both financial and clinical aspects. Therefore, how to manage this department has critical impact on the effectiveness and efficiency of the organization. Today, since the information in this department not only has different data structure but also is gathered from different data sources, a well defined, comprehensive dashboard can be an effective tool to enhance performance.
Yu, Z; Zheng, L; Zhang, Y; Li, J; Ma, Bao'an
2009-05-14
This study was designed to evaluate the functional and radiological outcomes of patients with complex tibial plateau fractures treated with double-buttress plate fixation. Sixty five cases of complex (Schatzker type V and VI) tibial plateau fractures were treated with double-buttress plate fixation in our centre from September 2001 to September 2006 through two separate plate incisions. Fifty four patients were followed up for a period ranging from 12 to 48 months and evaluated for the functional and radiological outcomes by a series of standard questionnaire and measurement. Due to the good exposure without any extensive soft-tissue dissection of the double-buttress plate fixation, the fractures in all 54 patients were healed and the treatment achieved greater than 90% of satisfactory-to-excellent rates of reduction. The mean time of bone union was 15.4 weeks (range, 12-30 weeks), and the mean time of full weight-bearing was 18.7 weeks (range, 14-26 weeks). At the final follow-up visit, no patients showed knee instability; the mean range of motion was 107.6 degrees (range, 85 degrees -130 degrees ). For all patients, no statistically significant difference in the functional outcomes was observed between their 6-months and final follow-up visits; or in the radiological findings between their immediate postoperative and final follow-up examinations. Double-buttress plate fixation is a feasible treatment option for bilcondylar and complex tibial plateau fractures. Although technically demanding, it offers reliable stability without additional postoperative adjuvant external fixation, and at the same time avoids extensive soft tissue dissection, allowing the early painless range of motion.
Kamunda, Caspah; Mathuthu, Manny; Madhuku, Morgan
2016-01-01
Radiological hazards associated with exposure to Naturally Occurring Radionuclides Materials from gold mine tailings in the province of Gauteng in South Africa were evaluated. A comparison was made with soil samples from a control area. In this study, gamma spectroscopy was used to measure the activity concentrations of these radionuclides in 56 soil samples from the mine tailings and 10 soil samples from the control area. The average activity concentrations in Bq∙kg−1 for Uranium-238, Thorium-232, and Potassium-40 from the mine tailings were found to be 785.3 ± 13.7, 43.9 ± 1.0 and 427.0 ± 13.1, respectively. On the other hand, the average activity concentrations in Bq∙kg−1 for Uranium-238, Thorium-232, and Potassium-40 from the control area were found to be 17.0.1 ± 0.4, 22.2 ± 0.5 and 496.8 ± 15.2, respectively. Radiological hazard parameters calculated from these activity concentrations were higher than recommended safe limits. In particular, calculated average values for the external hazard (Hex) and the internal hazard (Hin) from the mine tailings were found to be 2.4 and 4.5. Both these values were higher than unity, posing a significant health risk to the population in the area. PMID:26797624
Validation of an imaging based cardiovascular risk score in a Scottish population.
Kockelkoren, Remko; Jairam, Pushpa M; Murchison, John T; Debray, Thomas P A; Mirsadraee, Saeed; van der Graaf, Yolanda; Jong, Pim A de; van Beek, Edwin J R
2018-01-01
A radiological risk score that determines 5-year cardiovascular disease (CVD) risk using routine care CT and patient information readily available to radiologists was previously developed. External validation in a Scottish population was performed to assess the applicability and validity of the risk score in other populations. 2915 subjects aged ≥40 years who underwent routine clinical chest CT scanning for non-cardiovascular diagnostic indications were followed up until first diagnosis of, or death from, CVD. Using a case-cohort approach, all cases and a random sample of 20% of the participant's CT examinations were visually graded for cardiovascular calcifications and cardiac diameter was measured. The radiological risk score was determined using imaging findings, age, gender, and CT indication. Performance on 5-year CVD risk prediction was assessed. 384 events occurred in 2124 subjects during a mean follow-up of 4.25 years (0-6.4 years). The risk score demonstrated reasonable performance in the studied population. Calibration showed good agreement between actual and 5-year predicted risk of CVD. The c-statistic was 0.71 (95%CI:0.67-0.75). The radiological CVD risk score performed adequately in the Scottish population offering a potential novel strategy for identifying patients at high risk for developing cardiovascular disease using routine care CT data. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Pei-Jan P., E-mail: Pei-Jan.Lin@vcuhealth.org; Schueler, Beth A.; Balter, Stephen
2015-12-15
Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose-area-product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP-meter” has been revised to air kerma-area product (KAP) meter. The charge of TGmore » 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.« less
The Northern Marshall Islands Radiological Survey: data and dose assessments.
Robison, W L; Noshkin, V E; Conrado, C L; Eagle, R J; Brunk, J L; Jokela, T A; Mount, M E; Phillips, W A; Stoker, A C; Stuart, M L; Wong, K M
1997-07-01
Fallout from atmospheric nuclear tests, especially from those conducted at the Pacific Proving Grounds between 1946 and 1958, contaminated areas of the Northern Marshall Islands. A radiological survey at some Northern Marshall Islands was conducted from September through November 1978 to evaluate the extent of residual radioactive contamination. The atolls included in the Northern Marshall Islands Radiological Survey (NMIRS) were Likiep, Ailuk, Utirik, Wotho, Ujelang, Taka, Rongelap, Rongerik, Bikar, Ailinginae, and Mejit and Jemo Islands. The original test sites, Bikini and Enewetak Atolls, were also visited on the survey. An aerial survey was conducted to determine the external gamma exposure rate. Terrestrial (soil, food crops, animals, and native vegetation), cistern and well water samples, and marine (sediment, seawater, fish and clams) samples were collected to evaluate radionuclide concentrations in the atoll environment. Samples were processed and analyzed for 137Cs, 90Sr, 239+240Pu and 241Am. The dose from the ingestion pathway was calculated using the radionuclide concentration data and a diet model for local food, marine, and water consumption. The ingestion pathway contributes 70% to 90% of the estimated dose. Approximately 95% of the dose is from 137Cs. 90Sr is the second most significant radionuclide via ingestion. External gamma exposure from 137Cs accounts for about 10% to 30% of the dose. 239+240Pu and 241Am are the major contributors to dose via the inhalation pathway; however, inhalation accounts for only about 1% of the total estimated dose, based on surface soil levels and resuspension studies. All doses are computed for concentrations decay corrected to 1996. The maximum annual effective dose from manmade radionuclides at these atolls ranges from .02 mSv y(-1) to 2.1 mSv y(-1). The background dose in the Marshall Islands is estimated to be 2.4 mSv y(-1). The combined dose from both background and bomb related radionuclides ranges from slightly over 2.4 mSv y(-1) to 4.5 mSv y(-1). The 50-y integral dose ranges from 0.5 to 65 mSv.
ERIC Educational Resources Information Center
Goldring, Michelle A.
2012-01-01
This study seeks to find if the structure of the demands of the quarter system impacts the levels of depression reported in the school's student body. That is, can the external and systemic stressors at be linked to levels of depressive symptoms? This study proposes that depressive symptoms may be linked to external stresses exerted on the student…
Chow, Daniel S; Ha, Richard; Filippi, Christopher G
2015-01-01
OBJECTIVE; There is evidence in academic medicine that the number of authors per paper has increased over time. The goal of this study was to quantitatively analyze authorship trends in the field of radiology over 20 years. A search of the National Library of Medicine MEDLINE database was conducted to identify articles published by radiology departments between 1991 and 2012. Country of origin, article study design, and journal impact factor were recorded. The increase in number of authors per paper was assessed by linear and nonlinear regression. Pearson correlation was used to assess the relation between journal impact factor and number of authors. A total of 142,576 articles and 699,257 authors were identified during the study period. The mean number of authors per paper displayed linear growth from 3.9 to 5.7 (p < 0.0001). The proportion of single authors declined from 11% in 1991 to 4.4% in 2012. The number of clinical trials increased in a linear pattern, review articles in an exponential pattern, and case reports in a logistic pattern (p < 0.0001 for each). Countries with the highest number of authors per paper were Japan, Italy, and Germany. The number of articles funded by the U.S. National Institutes of Health (NIH) displayed exponential growth and of non-NIH-funded articles displayed linear growth (p < 0.0001 for each). A negligible relation was observed between journal impact factor and number of authors (Pearson r = 0.1066). Radiology has had a steady increase in mean number of authors per paper since the early 1990s that has varied by study design. The increase is probably multi-factorial and includes components of author inflation and increasing complexity of research. Findings support the need for reemphasis of authorship criteria to preserve authorship value and accountability.
NASA Astrophysics Data System (ADS)
Tahavori, Fatemeh
Respiratory motion induces uncertainty in External Beam Radiotherapy (EBRT), which can result in sub-optimal dose delivery to the target tissue and unwanted dose to normal tissue. The conventional approach to managing patient respiratory motion for EBRT within the area of abdominal-thoracic cancer is through the use of internal radiological imaging methods (e.g. Megavoltage imaging or Cone-Beam Computed Tomography) or via surrogate estimates of tumour position using external markers placed on the patient chest. This latter method uses tracking with video-based techniques, and relies on an assumed correlation or mathematical model, between the external surrogate signal and the internal target position. The marker's trajectory can be used in both respiratory gating techniques and real-time tracking methods. Internal radiological imaging methods bring with them limited temporal resolution, and additional radiation burden, which can be addressed by external marker-based methods that carry no such issues. Moreover, by including multiple external markers and placing them closer to the internal target organs, the effciency of correlation algorithms can be increased. However, the quality of such external monitoring methods is underpinned by the performance of the associated correlation model. Therefore, several new approaches to correlation modelling have been developed as part of this thesis and compared using publicly-available datasets. Highly competitive results have been obtained when compared against state-of-the-art methods. Marker-based methods also have the disadvantages of requiring manual set-up time for marker placement and patient positioning and potential issues with reproducibility of marker placement. This motivates the investigation of non-contact marker-free methods for use in EBRT, which is the main topic of this thesis. The Microsoft Kinect is used as an example of a low-cost consumer grade 3D depth camera for capturing and analysing external respiratory motion. This thesis makes the first presentation of detailed studies of external respiratory motion captured using such low-cost technology and demonstrates its potential in a healthcare environment. Firstly, the fundamental performance of a range of Microsoft Kinect sensors is assessed for use in radiotherapy (and potentially other healthcare applications), in terms of static and dynamic performance using both phantoms and volunteers. Then external respiratory motion is captured using the above technology from a group of 32 healthy volunteers and Principal Component Analysis (PCA) is applied to a region of interest encompassing the complete anterior surface to demonstrate breathing style. This work demonstrates that this surface motion can be compactly described by the first two PCA eigenvectors. The reproducibility of subject-specific EBRT set-up using conventional laser-based alignment and marker-based Deep Inspiration Breath Hold (DIBH) methods are also studied using the Microsoft Kinect sensor. A cohort of five healthy female volunteers is repeatedly set-up for left-sided breast cancer EBRT and multiple DIBH episodes captured over five separate sessions representing multiple fractionated radiotherapy treatment sessions, but without dose delivery. This provided an independent assessment that subjects were set-up and generally achieved variations within currently accepted margins of clinical practice. Moreover, this work demonstrated the potential role of consumer-grade 3D depth camera technology as a possible replacement for marker based set-up and DIBH management procedures. This brings with it the additional benefits of low cost, and potential through-put benefits, as patient set-up could ultimately be fully automated with this technology, and DIBH could be independently monitored without requiring preparatory manual intervention.
Code of Federal Regulations, 2012 CFR
2012-01-01
... structures, systems, and components important to radiological health and safety and the common defense and... report on the environmental impacts of the common design. 5. Upon a determination that each application.... 6. The NRC staff shall prepare draft and final environmental impact statements for each of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-25
... implementation. There would be no land use changes along transmission lines (no new lines would be required for...-term grid reliability and stability. Land use conditions would not change significantly PBNP, and there... result from the proposed EPU. Non-Radiological Impacts Land Use and Aesthetic Impacts Potential land use...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... Environs PBAPS consists of Units 1, 2, and 3 located on approximately 620 acres of land in Peach Bottom... proposed EPU are summarized below. Non-Radiological Impacts Land Use and Aesthetic Impacts Potential land... plant modifications. Therefore, land use conditions and visual aesthetics would not change significantly...
NASA Astrophysics Data System (ADS)
Murtinho, Felipe; Eakin, Hallie; López-Carr, David; Hayes, Tanya M.
2013-11-01
Despite debate regarding whether, and in what form, communities need external support for adaptation to environmental change, few studies have examined how external funding impacts adaptation decisions in rural resource-dependent communities. In this article, we use quantitative and qualitative methods to assess how different funding sources influence the initiative to adapt to water scarcity in the Colombian Andes. We compare efforts to adapt to water scarcity in 111 rural Andean communities with varied dependence on external funding for water management activities. Findings suggest that despite efforts to use their own internal resources, communities often need external support to finance adaptation strategies. However, not all external financial support positively impacts a community’s abilities to adapt. Results show the importance of community-driven requests for external support. In cases where external support was unsolicited, the results show a decline, or “crowding-out,” in community efforts to adapt. In contrast, in cases where communities initiated the request for external support to fund their own projects, findings show that external intervention is more likely to enhance or “crowds-in” community-driven adaptation.
The Impact of Parents, Child Care Providers, Teachers, and Peers on Early Externalizing Trajectories
Silver, Rebecca B.; Measelle, Jeffrey R.; Armstrong, Jeffrey M.; Essex, Marilyn J.
2010-01-01
This study utilized growth mixture modeling to examine the impact of parents, child care providers, teachers, and peers on the prediction of distinct developmental patterns of classroom externalizing behavior in elementary school. Among 241 children, three groups were identified. 84.6% of children exhibited consistently low externalizing behavior. The externalizing behavior of the Chronic High group (5.8%) remained elevated throughout elementary school; it increased over time in the Low Increasing group (9.5%). Negative relationships with teachers and peers in the kindergarten classroom increased the odds of having chronically high externalizing behavior. Teacher–child conflict increased the likelihood of a developmental pattern of escalating externalizing behavior. Boys were overrepresented in the behaviorally risky groups, and no sex differences in trajectory types were found. PMID:21094398
Lelario, M; Ciuffreda, P; Lupo, P; Bristogiannis, C; Vinci, R; Stoppino, L P; De Filippo, M; Macarini, L
2013-08-01
To evaluate any discrepancy between radiological reports for clinical purposes and for medicolegal purposes and to quantify its economic impact on repayments made by private insurance companies for meniscal injuries of the knee. The medical records obtained pertaining to 108 knee injury patients (mean age 43.3 years) assessed over a period of 12 months were analysed. Clinical medical reports, aimed at assessing the lesion, and medicolegal reports, drawn up with a view to quantifying compensation, were compared. Unlike reports for clinical purposes in reports for medicolegal purposes, in the evaluation of meniscal lesions, in addition to morphological features of lesions, chronological, topographical, severity and exclusion criteria were applied. To estimate the economic impact resulting from the biological damage, we consulted an actuarial table based on the 9-point minor incapacity classification system. Meniscal lesions not compatible with a traumatic event and therefore not eligible for an insurance payout were found in 56 patients. Of these, 37 failed exclusion criteria, while 19 failed to meet chronological criteria. This difference resulted in a reduction in compensation made by private insurance companies with savings estimated with a saving between euro 203,715.41 and euro 622,315.39. The use of a clinical report for medicolegal purposes can be a source of valuation error, as chronological and/or dynamic information regarding the trauma mechanism may be lacking. Therefore, the use of a full radiological appraisal allows a better damage's assessment and an adequate compensation for injuries.
Value of trainees in a radiology department. A retrospective semi-quantitative analysis.
Vardhanabhuti, V; Bhatnagar, G; Brown, S; James, J; Shuen, V; Sidhu, H; Thomas, R; Fox, B
2011-07-01
To examine the productivity (both economic and otherwise) of trainees within a radiology department at our institution. Productivity was measured in three ways: (1) independent workload contribution, (2) impact on on-call services, and (3) impact on day-to-day practice as perceived by consultant radiologists. Data were collected using retrospective searches on computerized radiology information system (CRIS), analysis of trainees and consultant rotas, and a questionnaire to consultants and trainees. Where possible, productivity was quantified in terms of number of programmed activities (PAs). The contribution of independent work by trainees in a single week was 52.75 PAs (or 1.45 PAs per trainee per week). In addition, the on-call contribution was 23.1 PAs per week (or 0.93 PAs per trainee per week). When both trainees and consultants report independently, productivity in a single list in most cases increased and can be as much as 197%. On calculating the economic impact, this amounts to significant savings of around £1.2million per year at our institution. Based upon objectively measurable areas of service provision, the employment of trainees yields considerable economic benefit. Furthermore, based upon qualitative methods we have shown that trainees contribute positively in those areas, which are much harder to quantifiably evaluate. These are benefits in addition to fundamental requirement to train future competent radiologists. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Mantero, J; Gazquez, M J; Bolivar, J P; Garcia-Tenorio, R; Vaca, F
2013-06-01
A study about the distribution of several radionuclides from the uranium and the thorium series radionuclides along the production process of a typical NORM industry devoted to the production of titanium dioxide has been performed. With this end the activity concentrations in raw materials, final product, co-products, and wastes of the production process have been determined by both gamma-ray and alpha-particle spectrometry. The main raw material used in the studied process (ilmenite) presents activity concentrations of around 300 Bq kg(-1) for Th-series radionuclides and 100 Bq kg(-1) for the U-series ones. These radionuclides in the industrial process are distributed in the different steps of the production process according mostly to the chemical behaviour of each radioelement, following different routes. As an example, most of the radium remains associated with the un-dissolved material waste, with activity concentrations around 3 kBq kg(-1) of (228)Ra and around 1 kBq kg(-1) of (226)Ra, while the final commercial products (TiO2 pigments and co-products) contain negligible amounts of radioactivity. The obtained results have allowed assessing the possible public radiological impact associated with the use of the products and co-products obtained in this type of industry, as well as the environmental radiological impact associated with the solid residues and liquid generated discharges. Copyright © 2013 Elsevier Ltd. All rights reserved.
Modes of information delivery in radiologic anatomy education: Impact on student performance.
Ketelsen, Dominik; Schrödl, Falk; Knickenberg, Inés; Heckemann, Rolf A; Hothorn, Torsten; Neuhuber, Winfried; Bautz, Werner A L; Grunewald, Markus
2007-01-01
This study provides a systematic assessment of different methods of delivering radiologic teaching content (lecture, printed text, and digital content delivery) under standard conditions, enabling comparison of the effectiveness of these methods. A printed atlas of sectional anatomy was used as a standard. Digital content was developed on the basis of the printed atlas. Lecturers used both the printed and the digital content to prepare lectures. Standardized teaching material thus created was presented to second-term undergraduate students who had attended the school's anatomy course, but had not received any radiology teaching. Multiple choice examinations were used to assess the students' ability to recognize anatomical structures in known as well as unknown images. In a survey, the students' subjective experience of the learning process was assessed. No difference was seen between the groups regarding examination results. Students preferred a combination of digital media and lectures by enthusiastic teachers. The shortage of teachers requires a compromise concerning the delivery of radiologic anatomy content in a medical school setting. Based on our results, we recommend a combined approach of lecture and digital content delivery.
Radiology employees' quality of work life.
Dargahi, Hussein; Changizi, Vahid; Jazayeri Gharabagh, Elaheh
2012-01-01
Quality of work Life (QWL) originates from interactions between employees' needs and relative organizational resources. QWL is aimed to improve and retain employees' satisfaction, productivity and effectiveness of all organizations. A cross-sectional descriptive study was conducted among 15 Tehran University of Medical Sciences. A Cross-Sectional, descriptive study was conducted among 15 Tehran University of Medical Sciences' Hospitals' Radiology Departments' Employees by QWL questionnaire. Respondents were asked to express their attitudes about a range of key factors as the most important issues impacting their QWL. The data was collected and analyzed by SPSS version 15 software. Most of the respondents indicated that they were unsatisfied and very unsatisfied with key factors of their QWL. Comparison of QWL key factors of TUMS radiology employees with the other countries indicated that most of the employees are unsatisfied with their poor QWL factors. We hope, the implications of these findings deliberate to improve QWL within each of TUMS hospitals radiology departments and also be relevant and value to policymakers of healthcare organizations in Iran. © 2012 Tehran University of Medical Sciences. All rights reserved.
El-Bahi, S M; Sroor, A; Mohamed, Gehan Y; El-Gendy, N S
2017-05-01
In this study, the activity concentrations of the natural radionuclides in phosphate rocks and its products were measured using a high- purity germanium detector (HPGe). The obtained activity results show remarkable wide variation in the radioactive contents for the different phosphate samples. The average activity concentration of 235 U, 238 U, 226 Ra, 232 Th and 40 K was found as (45, 1031, 786, 85 and 765Bq/kg) for phosphate rocks, (28, 1234, 457, 123 and 819Bq/kg) for phosphate fertilizers, (47, 663, 550, 79 and 870Bq/kg) for phosphogypsum and (25, 543, 409, 54 and 897Bq/kg) for single super phosphate respectively. Based on the measured activities, the radiological parameters (activity concentration index, absorbed gamma dose rate in outdoor and indoor and the corresponding annual effective dose rates and total excess lifetime cancer risk) were estimated to assess the radiological hazards. The total excess lifetime cancer risk (ELCR) has been calculated and found to be high in all samples, which related to high radioactivity, representing radiological risk for the health of the population. Copyright © 2017 Elsevier Ltd. All rights reserved.
Two decades of external peer review of cancer care in general hospitals; the Dutch experience.
Kilsdonk, Melvin J; Siesling, Sabine; Otter, Rene; van Harten, Wim H
2016-03-01
External peer review was introduced in general hospitals in the Netherlands in 1994 to assess and improve the multidisciplinary team approach in cancer care. This paper aims to explore the value, perceived impact, and (future) role of external peer review in cancer care. Semistructured interviews were held with clinicians, oncology nurses, and managers from fifteen general hospitals that participated in three rounds of peer review over a period of 16 years. Interviewees reflected on the goals and expectations, experiences, perceived impact, and future role of external peer review. Transcriptions of the interviews were coded to discover recurrent themes. Improving clinical care and organization were the main motives for participation. Positive impact was perceived on multiple aspects of care such as shared responsibilities, internal prioritization of cancer care, improved communication, and a clear structure and position of cancer care within general hospitals. Establishing a direct relationship between the external peer review and organizational or clinical impact proved to be difficult. Criticism was raised on the content of the program being too theoretical and organization-focussed after three rounds. According to most stakeholders, external peer review can improve multidisciplinary team work in cancer care; however, the acceptance is threatened by a perceived disbalance between effort and visible clinical impact. Leaner and more clinically focused programs are needed to keep repeated peer reviews challenging and worthwhile. © 2015 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Pereira, Andre; Atri, Mostafa; Rogalla, Patrik; Huynh, Thien; O'Malley, Martin E
2015-11-01
The value of a teaching case repository in radiology training programs is immense. The allocation of resources for putting one together is a complex issue, given the factors that have to be coordinated: hardware, software, infrastructure, administration, and ethics. Costs may be significant and cost-effective solutions are desirable. We chose Medical Imaging Resource Center (MIRC) to build our teaching file. It is offered by RSNA for free. For the hardware, we chose the Raspberry Pi, developed by the Raspberry Foundation: a small control board developed as a low cost computer for schools also used in alternative projects such as robotics and environmental data collection. Its performance and reliability as a file server were unknown to us. For the operational system, we chose Raspbian, a variant of Debian Linux, along with Apache (web server), MySql (database server) and PHP, which enhance the functionality of the server. A USB hub and an external hard drive completed the setup. Installation of software was smooth. The Raspberry Pi was able to handle very well the task of hosting the teaching file repository for our division. Uptime was logged at 100 %, and loading times were similar to other MIRC sites available online. We setup two servers (one for backup), each costing just below $200.00 including external storage and USB hub. It is feasible to run RSNA's MIRC off a low-cost control board (Raspberry Pi). Performance and reliability are comparable to full-size servers for the intended purpose of hosting a teaching file within an intranet environment.
Fadel, Mohamed; Ahmed, Mohamed Ali; Al-Dars, Ahmed Mounir; Maabed, Mustafa Ahmed; Shawki, Hashem
2015-03-01
The purpose of this study was to evaluate the outcome of Ilizarov external fixation (IE) versus dynamic compression plate (PO) in the management of extra-articular distal tibial fractures. Between 2010 and 2011, extra-articular distal tibial fractures in 40 consecutive patients met the inclusion criteria. They were classified according to AO classification fracture type A (A1, A2, and A3). In a randomized method, two equal groups were managed using either IE or PO. PO was performed using open reduction and internal fixation (ORIF) and DCP through anterolateral approach. IE was done using Ilizarov frame. For the PO group, non-weight bearing ambulation was permitted on the second postoperative day but partial weight bearing was permitted according to the progression in union criteria clinically and radiologically. For the IE group, weight bearing started as tolerated from the first postoperative day. Physiotherapy and pin-site care was performed by the patient themselves. Modified Mazur ankle score was applied to IE (excellent 10, good 10) and in PO (excellent 2, good 8, poor 6). Data were statically analysed using (Mann-Whitney test). The rate of healing in the IE group (average 130) was higher than the PO (average 196.5); plus, there were no cases of delayed union or nonunion in the IE group (p value 0.003). It was found that IE compared with PO provides provision of immediate weight bearing as tolerated following postoperative recovery, irrespective of radiological or clinical healing with no infection, deformity or non-union.
Mutch, S J; Wentworth, S D P
2007-11-01
Modern neonatal incubators incorporate an X-ray tray device into the mattress support structure to facilitate patient examination with minimal disturbance and distress. However, the usual method of examination is to place the image plate directly underneath the baby. Users often cite radiological reasons for not using X-ray trays but modern quantitative evidence is lacking. This work looks at the technical and clinical aspects of imaging neonates in incubators and the impact that these may have in determining the imaging protocol. A number of hospitals were surveyed to determine their current method of examination and the reasons for their preference. Experimental measurements of the radiological impact of using (or not using) the X-ray tray were performed for a range of neonatal incubators. The average dose to the image plate was 5.9 microGy (range 5.4-6.4 microGy) for the "plate on mattress" method and 3.0 microGy (2.0-3.8 microGy) when using the tray--a 49% reduction owing to the mattress support materials. However, when using a computed radiography (CR) imaging system, the image quality differences were marginal. Survey results indicated that nurses preferred to use the tray but that radiographers were reluctant. We conclude that incubator manufacturers could do much to improve the radiological performance of their equipment and we offer recommendations. We also conclude that, with appropriate nurse and radiographer training and the advent of CR imaging systems, use of X-ray tray facilities may optimize imaging of the neonate in the incubator.
Radiological criteria for unrestricted use of sites containing norm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernhardt, D.E.; Rogers, V.C.; Nielson, K.K.
1996-06-01
Natural occurring radioactive materia (NORM) is redistributed in the environment as a result of many mineral recovery and processing industries. There are not federal regulations specifying criteria for NORM contaminated sites; however, several states have promulgated regulations. The regulations promulgated by the states generally focus on NORM from oil and gas production, the primary focus of the assessments for this paper. The criteria for residual NORM in soil are generally (1) 0.18 Bq g{sup -1} in the surface 15 cm of soil and 0.6 Bq g{sup -1} at depth or (2) 1.1 Bq g{sup -1}, with a limitation on themore » radon flux. The primary radiation dose pathways for unrestricted use of land are external gamma exposure and exposure related to indoor radon. Radiation doses vary by over an order of magnitude based on different ratios of {sup 226}Ra to {sup 228}Ra concentrations, biological uptake parameters related to NORM, and the different radon emanation factors for oil field scale and sludge. A {sup 226}Ra criterion of 1.1 Bq g{sup -1} results in a dose of about 2 mSv y{sup -1} from external gamma and about 3 mSv y{sup -1} from radon for a general crawl-space type residence home scenario. The chemical and physical characteristics of the NORM and site-specific factors are important considerations in the assessments. The radon dose would be about 3 times higher for NORM in sludge, vs. the assumption of pipe scale. The structural characteristics of residences (e.g., slab-on-grade, crawl-space, or trailer) also have a significant impact on the potential doses to residences.« less
Karimi, Saeed; Agharahimi, Zahra; Yaghoubi, Maryam
2012-01-01
Outsourcing in healthcare is a cost-effective strategy that can lead to increase services quality. The aim of this study was to determine the types of services that have been outsourced in educational hospitals in Isfahan and to investigate managers' view about the impact of Outsourcing. A descriptive-survey study carried out in 2010. Our samples consisted of 100 educational hospital and treatment deputy senior managers of Isfahan University of Medical Sciences and 53 usable questionnaires were received. Survey instrument main points were the extent to which educational hospital outsource services and the impact of Outsourcing. Reliability and validity of the questionnaire have been verified. Data are analyzed with SPSS18 software. The results for medical-diagnostics services showed physiotherapy, radiology, and ultrasound that have the highest rate (33%) of being outsourced. Between logistic and administrative activities, housekeeping, and facility engineering maintenance services are the highest rate of outsourced (100%) and green space, CSR, laundry, and medical records are the lowest rate of outsourced (16%). In managers' view, in relation to advantages of outsourcing, pay more attention to internal and external customers in private sector (57.2%) was the highest. In relation to disadvantages of outsourcing, costs increase for the patients (45.6%) was the highest. In relation to barriers of outsourcing, forgetting the goal of outsourcing (efficiency) (60.6%) was the highest. Finally, managers' views about outsourcing in health services organizations were rather acceptable, but in their views, there are barriers in implementation of outsourcing and they are focused on removing the barriers before outsourcing. Fundamental infrastructure developments as making competing market, promoting of cultures, education, modifying the management attitude and approach, and establishing incentive policies are emphasized for successful implementation of outsourcing.
Karimi, Saeed; Agharahimi, Zahra; Yaghoubi, Maryam
2012-01-01
Purpose: Outsourcing in healthcare is a cost-effective strategy that can lead to increase services quality. The aim of this study was to determine the types of services that have been outsourced in educational hospitals in Isfahan and to investigate managers’ view about the impact of Outsourcing. Design/Methodology/Approach: A descriptive-survey study carried out in 2010. Our samples consisted of 100 educational hospital and treatment deputy senior managers of Isfahan University of Medical Sciences and 53 usable questionnaires were received. Survey instrument main points were the extent to which educational hospital outsource services and the impact of Outsourcing. Reliability and validity of the questionnaire have been verified. Data are analyzed with SPSS18 software. Findings: The results for medical-diagnostics services showed physiotherapy, radiology, and ultrasound that have the highest rate (33%) of being outsourced. Between logistic and administrative activities, housekeeping, and facility engineering maintenance services are the highest rate of outsourced (100%) and green space, CSR, laundry, and medical records are the lowest rate of outsourced (16%). In managers’ view, in relation to advantages of outsourcing, pay more attention to internal and external customers in private sector (57.2%) was the highest. In relation to disadvantages of outsourcing, costs increase for the patients (45.6%) was the highest. In relation to barriers of outsourcing, forgetting the goal of outsourcing (efficiency) (60.6%) was the highest. Conclusion: Finally, managers’ views about outsourcing in health services organizations were rather acceptable, but in their views, there are barriers in implementation of outsourcing and they are focused on removing the barriers before outsourcing. Fundamental infrastructure developments as making competing market, promoting of cultures, education, modifying the management attitude and approach, and establishing incentive policies are emphasized for successful implementation of outsourcing. PMID:23555128
Diagnostic Radiology--The Impact of New Technology.
ERIC Educational Resources Information Center
Harrison, R. M.
1989-01-01
Discussed are technological advances applying computer techniques for image acquisition and processing, including digital radiography, computed tomography, and nuclear magnetic resonance imaging. Several diagrams and pictures showing the use of each technique are presented. (YP)
Kremer, Kristen P.; Flower, Andrea; Huang, Jin; Vaughn, Michael G.
2016-01-01
The aim of this study was to examine the longitudinal association between externalizing and internalizing behavior and children’s academic achievement, particularly in terms of whether these variables varied as a function of gender and race. Data pertaining to externalizing and internalizing behavior, academic achievement, gender, and race from three waves of the Child Development Supplement of the Panel Study of Income Dynamics (N = 2028) were used. Results indicate that behavior problems had a negative relationship with academic performance and some of these associations endured over time. Externalizing behavior impacted reading scores more negatively for females compared to males at baseline, but the impact of externalizing behavior on long-term reading outcomes did not vary by gender. Externalizing behavior impacted reading scores more negatively for Black children than White children at multiple points in time. Differences between males, females, Black, and White children concerning behavior and achievement are explained. Implications, limitations, and ideas for future research are also presented. PMID:28529397
Siboni, Renaud; Joseph, Etienne; Blasco, Laurent; Barbe, Coralie; Bajolet, Odile; Diallo, Saïdou; Ohl, Xavier
2018-06-07
Management of septic non-union of the tibia requires debridement and excision of all infected bone and soft tissues. Various surgical techniques have been described to fill the bone defect. The "Induced Membrane" technique, described by A. C. Masquelet in 1986, is a two-step procedure using a PMMA cement spacer around which an induced membrane develops, to be used in the second step as a bone graft holder for the bone graft. The purpose of this study was to assess our clinical and radiological results with this technique in a series managed in our department. Nineteen traumatic septic non-unions of the tibia were included in a retrospective single-center study between November 2007 and November 2014. All patients were followed up clinically and radiologically to assess bone union time. Multivariate analysis was used to identify factors influencing union. The series comprised 4 women and 14 men (19 legs); mean age was 53.9 years. Vascularized flap transfer was required in 26% of cases before the first stage of treatment. All patients underwent a two-step procedure, with a mean interval of 7.9 weeks. Mean bone defect after the first step was 52.4mm. The bone graft was harvested from the iliac crest in the majority of cases (18/19). The bone was stabilized with an external fixator, locking plate or plaster cast after the second step. Mean follow-up was 34 months. Bony union rate was 89% (17/19), at a mean 16 months after step 2. Eleven patients underwent one or more (mean 2.1) complementary procedures. Severity of index fracture skin opening was significantly correlated with union time (Gustilo III vs. Gustilo I or II, p=0.028). A trend was found for negative impact of smoking on union (p=0.06). Bone defect size did not correlate with union rate or time. The union rate was acceptable, at 89%, but with longer union time than reported in the literature. Many factors could explain this: lack of rigid fixation after step 2 (in case of plaster cast or external fixator), or failure to cease smoking. The results showed that the induced membrane technique is effective in treating tibial septic non-union, but could be improved by stable fixation after the second step and by cessation of smoking. IV, Retrospective study. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goossens, L.H.J.; Kraan, B.C.P.; Cooke, R.M.
1997-12-01
The development of two new probabilistic accident consequence codes, MACCS and COSYMA, was completed in 1990. These codes estimate the consequence from the accidental releases of radiological material from hypothesized accidents at nuclear installations. In 1991, the US Nuclear Regulatory Commission and the Commission of the European Communities began cosponsoring a joint uncertainty analysis of the two codes. The ultimate objective of this joint effort was to systematically develop credible and traceable uncertainty distributions for the respective code input variables. A formal expert judgment elicitation and evaluation process was identified as the best technology available for developing a library ofmore » uncertainty distributions for these consequence parameters. This report focuses on the results of the study to develop distribution for variables related to the MACCS and COSYMA deposited material and external dose models. This volume contains appendices that include (1) a summary of the MACCS and COSYMA consequence codes, (2) the elicitation questionnaires and case structures, (3) the rationales and results for the panel on deposited material and external doses, (4) short biographies of the experts, and (5) the aggregated results of their responses.« less
Experimental approaches to assessing the impact of a cesium chloride radiological dispersal device
Lee, S.; Gibb, Snyder E.; Barzyk, J.; McGee, J.; Koenig, A.
2008-01-01
The US EPA, as a part of the Chemical, Biological, Radiological-Nuclear, and Explosives (CBRNE) Research and Technology Initiative (CRTI) project team, is currently working to assess the impacts of an urban radiological dispersion device (RDD) and to develop containment and decontamination strategies. Three efforts in this area are currently underway: development of a laboratory-scale cesium chloride deposition method to mimic a RDD; assessment of cesium (Cs) penetration depth and pathways in urban materials using two dimensional (2-D) mapping laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS); and experimental determination of distribution coefficients (kd) for Cs in water-building material systems. It is critical that, when performing laboratory-scale experiments to assess the fate of Cs from an RDD, the Cs particle deposition method mimics the RDD deposition. Once Cs particles are deposited onto urban surfaces, 2-D mapping of Cs concentrations using LA-ICP-MS is a critical tool for determining Cs transport pathways through these materials. Lastly, distribution coefficients are critical for understanding the transport of Cs in urban settings when direct measurements of its penetration depth are unavailable. An assessment of the newly developed deposition method along with preliminary results from the penetration experiments are presented in this paper.
Biological risks of medical irradiations: Medical physics monograph 5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fullerton, G.D., Kopp, D.T.; Waggener, R.G.; Webster, E.W.
1980-01-01
This book is the fifth in a series of monographs by the American Association of Physicists in Medicine (AAPM) and is a compendium of papers presented at an AAPM regional symposium conducted in San Antonio in July 1980. The book is divided into three sections: (1) biological fundamentals of ionizing radiation, (2) risk evaluation and reduction in three principle radiologic subspecialties (diagnostic radiology, nuclear medicine and radiation therapy), and (3) medical-legal implications. The first section includes a historical review of radiation biology, including a discussion of somatic and genetic effects and statistical approaches to risk estimates. The section on riskmore » evaluation and reduction includes a good review of the units of exposure and activity including the international (SI) system employing the gray, becquerel, and seivert that respectively replace the rad, Curie, and rem. The unavoidable problem of legal responsibility and liability is the subject of the third, and last, section of the monograph. A chapter summarizing the legal history of medical irradiation also includes a glossary of pertinent legal terms. Recent court decisions that impact upon the clinical use of radiation are presented and discussed as well as proposed changes in federal guidelines that could have a large impact on the practice of medicine in general and radiology in particular. (JMT)« less
Mansoori, Bahar; Vidal, Lorenna L; Applegate, Kimberly; Rawson, James V; Novak, Ronald D; Ros, Pablo R
2013-10-01
The Patient Protection and Affordable Care Act (ACA) generated significant media attention since its inception. When the law was approved in 2010, the U.S. health care system began facing multiple changes to adapt and to incorporate measures to meet the new requirements. These mandatory changes will be challenging for academic radiology departments (ARDs) since they will need to promote a shift from a volume-focused to a value-focused practice. This will affect all components of the mission of ARDs, including clinical practice, education, and research. A unique key element to success in this transition is to focus on both quality and safety, thus improving the value of radiology in the post-ACA era. Given the changes ARDs will face during the implementation of ACA, suggestions are provided on how to adapt ARDs to this new environment. Copyright © 2013. Published by Elsevier Inc.
Artificial intelligence in radiology.
Hosny, Ahmed; Parmar, Chintan; Quackenbush, John; Schwartz, Lawrence H; Aerts, Hugo J W L
2018-05-17
Artificial intelligence (AI) algorithms, particularly deep learning, have demonstrated remarkable progress in image-recognition tasks. Methods ranging from convolutional neural networks to variational autoencoders have found myriad applications in the medical image analysis field, propelling it forward at a rapid pace. Historically, in radiology practice, trained physicians visually assessed medical images for the detection, characterization and monitoring of diseases. AI methods excel at automatically recognizing complex patterns in imaging data and providing quantitative, rather than qualitative, assessments of radiographic characteristics. In this Opinion article, we establish a general understanding of AI methods, particularly those pertaining to image-based tasks. We explore how these methods could impact multiple facets of radiology, with a general focus on applications in oncology, and demonstrate ways in which these methods are advancing the field. Finally, we discuss the challenges facing clinical implementation and provide our perspective on how the domain could be advanced.
THE ROLE OF THE CONSEQUENCE MANAGEMENT HOME TEAM IN THE FUKUSHIMA DAIICHI RESPONSE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pemberton, Wendy; Mena, RaJah; Beal, William
The Consequence Management Home Team is a U.S. Department of Energy/National Nuclear Security Administration asset. It assists a variety of response organizations with modeling; radiological operations planning; field monitoring techniques; and the analysis, interpretation, and distribution of radiological data. These reach-back capabilities are activated quickly to support public safety and minimize the social and economic impact of a nuclear or radiological incident. In the Fukushima Daiichi response, the Consequence Management Home Team grew to include a more broad range of support than was historically planned. From the early days of the response to the continuing involvement in supporting late phasemore » efforts, each stage of the Consequence Management Home Team support had distinct characteristics in terms of management of incoming data streams as well as creation of products. Regardless of stage, the Consequence Management Home Team played a critical role in the Fukushima Daiichi response effort.« less
Impact of external conditions on energy consumption in industrial halls
NASA Astrophysics Data System (ADS)
Żabnieńśka-Góra, Alina
2017-11-01
The energy demand for heating the halls buildings is high. The impact on this may have the technology of production, building construction and technology requirements (HVAC systems). The isolation of the external partitions, the location of the object in relation to the surrounding buildings and the degree of the interior insolation (windows and skylights) are important in the context of energy consumption. The article discusses the impact of external conditions, wind and sunlight on energy demand in the industrial hall. The building model was prepared in IDA ICE 4.0 simulation software. Model validation was done based on measurements taken in the analyzed building.
NASA Astrophysics Data System (ADS)
Brandt, Jørgen; Andersen, Mikael S.; Bønløkke, Jakob; Christensen, Jesper H.; Geels, Camilla; Hansen, Kaj M.; Hertel, Ole; Im, Ulas; Jensen, Steen S.; Ketzel, Matthias; Nielsen, Ole-Kenneth; Plejdrup, Marlene S.; Sigsgaard, Torben
2016-04-01
A high-resolution assessment of health impacts from air pollution and related external cost has been conducted for Denmark using the integrated EVA model system. The EVA system is based on the impact-pathway methodology, where the site-specific emissions will result, via atmospheric transport and chemistry, in a concentration distribution, which together with detailed population data, is used to estimate the population-level exposure. Using exposure-response functions and economic valuations, the exposure is transformed into impacts on human health and related external costs. In this study we have used a coupling of two chemistry transport models to calculate the air pollution concentration at different domain and scales; the Danish Eulerian Hemispheric Model (DEHM) to calculate the air pollution levels in the Northern Hemisphere with a resolution down to 5.6 km x 5.6 km and the Urban Background Model (UBM) to further calculate the air pollution in Denmark at 1 km x 1 km resolution using results from DEHM as boundary conditions. Both the emission data as well as the population density has been represented in the model system with the same high resolution. Previous health impact assessments related to air pollution have been made on a lower resolution. In this study, the integrated model system, EVA, has been used to estimate the health impacts and related external cost for Denmark at a 1 km x 1 km resolution. New developments of the integrated model system will be presented as well as the development of health impacts and related external costs in Europe and Denmark over a period of 36 years (1979-2014). Acknowledgements This work was funded by: DCE - National Centre for Environment and Energy. Project: "Health impacts and external costs from air pollution in Denmark over 25 years" and NordForsk under the Nordic Programme on Health and Welfare. Project: "Understanding the link between air pollution and distribution of related health impacts and welfare in the Nordic countries (NordicWelfAir)".
Barreda, F; Contardo, C; León, A; Navarrete, J; Figueroa, R; Attanasio, F
1989-01-01
Primary Sclerosing Cholangitis (PSC) is an unusual chronic, cholestatic disease of unknown etiology, more frequently seen in young adults in close relationship with Chronic Ulcerative Colitis. We report the case of a 30 year old woman, coming from the peruvian amazon with PSC associated with Sjögren Syndrome, Chronic Pancreatitis and Retroperitoneal Fibrosis, without colonic involvement. She was treated with external biliary drainage and controlled for 12 months. In this paper, clinical, biochemical, radiological, histological and therapeutic features are reviewed as well as its possible immunologie autoimmune origin.
Kühne, C A; Taeger, G; Nast-Kolb, D; Ruchholtz, S
2003-03-01
Infected tumor endoprosthesis of the knee in young patients can prove to be challenging. Common procedures are débridement and prosthesis reimplantation, amputation, revision arthroplasty, and arthrodesis. We report the case of a 44-year-old man treated by arthrodesis followed by callus distraction after removal of an infected tumor mega prosthesis (Kotz type). Callus distraction was performed over a distance of 11 cm in 4 months using a femorotibial intramedullary nail with an external traction rope-winch system. The clinical, radiological, technical, and therapeutic features are discussed.
Army Modernization Strategy 2008
2008-01-01
22 Response to Natural Disasters ...2Section 6: Chemical, Biological, Radiological and Nuclear Defense ...................................................43 2Section 7: Battle...economic impacts of globalization Population growth—especially in less-developed countries—will expose a resulting “youth bulge” to anti-government and
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-08
... affect radiation exposures to plant workers and members of the public. Therefore, no changes or different... socioeconomic resources. Therefore, no changes to or different types of non-radiological environmental impacts...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ballinger, Marcel Y.; Gervais, Todd L.; Barnett, J. Matthew
2012-06-05
In 2002, the EPA amended 40 CFR 61 Subpart H and 40 CFR 61 Appendix B Method 114 to include requirements from ANSI/HPS N13.1-1999 Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities for major emission points. Additionally, the WDOH amended the Washington Administrative Code (WAC) 246-247 Radiation protection-air emissions to include ANSI/HPS N13.1-1999 requirements for major and minor emission points when new permitting actions are approved. A result of the amended regulations is the requirement to prepare a written technical basis for the radiological air emission sampling and monitoring program. A keymore » component of the technical basis is the Potential Impact Category (PIC) assigned to an emission point. This paper discusses the PIC assignments for the Pacific Northwest National Laboratory (PNNL) Integrated Laboratory emission units; this revision includes five PIC categories.« less
The stability of freak waves with regard to external impact and perturbation of initial data
NASA Astrophysics Data System (ADS)
Smirnova, Anna; Shamin, Roman
2014-05-01
We investigate solutions of the equations, describing freak waves, in perspective of stability with regard to external impact and perturbation of initial data. The modeling of freak waves is based on numerical solution of equations describing a non-stationary potential flow of the ideal fluid with a free surface. We consider the two-dimensional infinitely deep flow. For waves modeling we use the equations in conformal variables. The variant of these equations is offered in [1]. Mathematical correctness of these equations was discussed in [2]. These works establish the uniqueness of solutions, offer the effective numerical solution calculation methods, prove the numerical convergence of these methods. The important aspect of numerical modeling of freak waves is the stability of solutions, describing these waves. In this work we study the questions of stability with regards to external impact and perturbation of initial data. We showed the stability of freak waves numerical model, corresponding to the external impact. We performed series of computational experiments with various freak wave initial data and random external impact. This impact means the power density on free surface. In each experiment examine two waves: the wave that was formed by external impact and without one. In all the experiments we see the stability of equation`s solutions. The random external impact practically does not change the time of freak wave formation and its form. Later our work progresses to the investigation of solution's stability under perturbations of initial data. We take the initial data that provide a freak wave and get the numerical solution. In common we take the numerical solution of equation with perturbation of initial data. The computing experiments showed that the freak waves equations solutions are stable under perturbations of initial data.So we can make a conclusion that freak waves are stable relatively external perturbation and perturbation of initial data both. 1. Zakharov V.E., Dyachenko A.I., Vasilyev O.A. New method for numerical simulation of a nonstationary potential flow of incompressible fluid with a free surface// Eur. J.~Mech. B Fluids. 2002. V. 21. P. 283-291. 2. R.V. Shamin. Dynamics of an Ideal Liquid with a Free Surface in Conformal Variables // Journal of Mathematical Sciences, Vol. 160, No. 5, 2009. P. 537-678. 3. R.V. Shamin, V.E. Zakharov, A.I. Dyachenko. How probability for freak wave formation can be found // THE EUROPEAN PHYSICAL JOURNAL - SPECIAL TOPICS Volume 185, Number 1, 113-124, DOI: 10.1140/epjst/e2010-01242-y
Rancher, Caitlin E; Shoemaker, Jody M; Petree, Linda E; Holdsworth, Mark; Phillips, John P; Helitzer, Deborah L
2016-10-11
Returning neuroimaging incidental findings (IF) may create a challenge to research participants' health literacy skills as they must interpret and make appropriate healthcare decisions based on complex radiology jargon. Disclosing IF can therefore present difficulties for participants, research institutions and the healthcare system. The purpose of this study was to identify the extent of the health literacy challenges encountered when returning neuroimaging IF. We report on findings from a retrospective survey and focus group sessions with major stakeholders involved in disclosing IF. We surveyed participants who had received a radiology report from a research study and conducted focus groups with participants, parents of child participants, Institutional Review Board (IRB) members, investigators and physicians. Qualitative thematic analyses were conducted using standard group-coding procedures and descriptive summaries of health literacy scores and radiology report outcomes are examined. Although participants reported high health literacy skills (m = 87.3 on a scale of 1-100), 67 % did not seek medical care when recommended to do so; and many participants in the focus groups disclosed they could not understand the findings described in their report. Despite their lack of understanding, participants desire to have information about their radiology results, and the investigators feel ethically inclined to return findings. The language in clinically useful radiology reports can create a challenge for participants' health literacy skills and has the potential to negatively impact the healthcare system and investigators conducting imaging research. Radiology reports need accompanying resources that explain findings in lay language, which can help reduce the challenge caused by the need to communicate incidental findings.
Uncited Research Articles in Popular United States General Radiology Journals.
Rosenkrantz, Andrew B; Chung, Ryan; Duszak, Richard
2018-05-03
This study aimed to characterize articles in popular general radiology journals that go uncited for a decade after publication. Using the Web of Science database, we identified annual citation counts for 13,459 articles published in Radiology, American Journal of Roentgenology, and Academic Radiology between 1997 and 2006. From this article cohort, we then identified all original research articles that accrued zero citations within a decade of publication. A concurrent equal-sized cohort of most cited articles was created. Numerous characteristics of the uncited and most cited articles were identified and compared. Only 47 uncited articles went uncited for a decade after publication. When compared to the 47 most cited articles over that same window, the uncited articles were significantly (P < .05) less likely to have a clinical focus, include a nonradiologist author and authors from multiple institutions and multiple nations, report research funding support and statistically significant findings, and include punctuation marks in their titles. Compared to the most cited articles, uncited articles also had significantly (P < .05) fewer authors, abstract words, manuscript words, references, tables, figure parts, and pages, as well as smaller subject sample sizes. Of articles published in popular general radiology journals, only a very small number of original research investigations remained uncited a decade after publication. Given that citations reflect the impact of radiology research, this observation suggests that journals are appropriately selecting meaningful work. Investigators seeking to avoid futile publication might consider their research initiatives in light of these characteristics. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Grignon, L; Keiper, M; Vavricek, J; Horsley, W; Murphy, R; Grignon, A; Yu, F
2014-08-01
Over the past several years, decreased demand for and increased supply of imaging services has increased competition among outpatient imaging centers in the United States. This study hypothesizes that using a radiology sales representative and neuroradiologist as a team in marketing and sales will increase imaging referrals in outpatient imaging. From January to December 2009, baseline monthly physician referral data of CT and MR scans of 19 referring clinicians (neurologists, neurosurgeons, and anesthesiologists) to an outpatient radiology group were collected. During that time, a nonphysician radiology sales representative visited the referring clinicians' offices every 2 weeks. From January to June 2010, the same radiology sales representative visited the referring clinicians' offices every 2 weeks but was accompanied by a neuroradiologist once a month. From July 2010 to June 2011, the same radiology sales representative visited the referring clinicians' offices twice a month without a neuroradiologist. Cross-sectional imaging referral volumes were approximately 2.5 times greater during the 6-month period using the neuroradiologist for direct physician-to-physician marketing when compared with the volumes achieved with the sales representative alone, and continued neuroradiologist involvement in marketing and sales is required to maintain referral volumes over time. The impact on imaging referral volumes during the 6-month use of the neuroradiologist for direct physician-to-physician marketing in this study supports the assertion that neuroradiologist visits are an important element in establishing and maintaining a relationship with the referring clinician's office and thereby maximizing imaging referrals. © 2014 by American Journal of Neuroradiology.
Applying Systems Engineering Reduces Radiology Transport Cycle Times in the Emergency Department.
White, Benjamin A; Yun, Brian J; Lev, Michael H; Raja, Ali S
2017-04-01
Emergency department (ED) crowding is widespread, and can result in care delays, medical errors, increased costs, and decreased patient satisfaction. Simultaneously, while capacity constraints on EDs are worsening, contributing factors such as patient volume and inpatient bed capacity are often outside the influence of ED administrators. Therefore, systems engineering approaches that improve throughput and reduce waste may hold the most readily available gains. Decreasing radiology turnaround times improves ED patient throughput and decreases patient waiting time. We sought to investigate the impact of systems engineering science targeting ED radiology transport delays and determine the most effective techniques. This prospective, before-and-after analysis of radiology process flow improvements in an academic hospital ED was exempt from institutional review board review as a quality improvement initiative. We hypothesized that reorganization of radiology transport would improve radiology cycle time and reduce waste. The intervention included systems engineering science-based reorganization of ED radiology transport processes, largely using Lean methodologies, and adding no resources. The primary outcome was average transport time between study order and complete time. All patients presenting between 8/2013-3/2016 and requiring plain film imaging were included. We analyzed electronic medical record data using Microsoft Excel and SAS version 9.4, and we used a two-sample t-test to compare data from the pre- and post-intervention periods. Following the intervention, average transport time decreased significantly and sustainably. Average radiology transport time was 28.7 ± 4.2 minutes during the three months pre-intervention. It was reduced by 15% in the first three months (4.4 minutes [95% confidence interval [CI] 1.5-7.3]; to 24.3 ± 3.3 min, P=0.021), 19% in the following six months (5.4 minutes, 95% CI [2.7-8.2]; to 23.3 ± 3.5 min, P=0.003), and 26% one year following the intervention (7.4 minutes, 95% CI [4.8-9.9]; to 21.3 ± 3.1 min, P=0.0001). This result was achieved without any additional resources, and demonstrated a continual trend towards improvement. This innovation demonstrates the value of systems engineering science to increase efficiency in ED radiology processes. In this study, reorganization of the ED radiology transport process using systems engineering science significantly increased process efficiency without additional resource use.
Applying Systems Engineering Reduces Radiology Transport Cycle Times in the Emergency Department
White, Benjamin A.; Yun, Brian J.; Lev, Michael H.; Raja, Ali S.
2017-01-01
Introduction Emergency department (ED) crowding is widespread, and can result in care delays, medical errors, increased costs, and decreased patient satisfaction. Simultaneously, while capacity constraints on EDs are worsening, contributing factors such as patient volume and inpatient bed capacity are often outside the influence of ED administrators. Therefore, systems engineering approaches that improve throughput and reduce waste may hold the most readily available gains. Decreasing radiology turnaround times improves ED patient throughput and decreases patient waiting time. We sought to investigate the impact of systems engineering science targeting ED radiology transport delays and determine the most effective techniques. Methods This prospective, before-and-after analysis of radiology process flow improvements in an academic hospital ED was exempt from institutional review board review as a quality improvement initiative. We hypothesized that reorganization of radiology transport would improve radiology cycle time and reduce waste. The intervention included systems engineering science-based reorganization of ED radiology transport processes, largely using Lean methodologies, and adding no resources. The primary outcome was average transport time between study order and complete time. All patients presenting between 8/2013–3/2016 and requiring plain film imaging were included. We analyzed electronic medical record data using Microsoft Excel and SAS version 9.4, and we used a two-sample t-test to compare data from the pre- and post-intervention periods. Results Following the intervention, average transport time decreased significantly and sustainably. Average radiology transport time was 28.7 ± 4.2 minutes during the three months pre-intervention. It was reduced by 15% in the first three months (4.4 minutes [95% confidence interval [CI] 1.5–7.3]; to 24.3 ± 3.3 min, P=0.021), 19% in the following six months (5.4 minutes, 95% CI [2.7–8.2]; to 23.3 ± 3.5 min, P=0.003), and 26% one year following the intervention (7.4 minutes, 95% CI [4.8–9.9]; to 21.3 ± 3.1 min, P=0.0001). This result was achieved without any additional resources, and demonstrated a continual trend towards improvement. This innovation demonstrates the value of systems engineering science to increase efficiency in ED radiology processes. Conclusion In this study, reorganization of the ED radiology transport process using systems engineering science significantly increased process efficiency without additional resource use. PMID:28435492
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-02-01
Pipe Crawler{reg_sign} is a pipe surveying system for performing radiological characterization and/or free release surveys of piping systems. The technology employs a family of manually advanced, wheeled platforms, or crawlers, fitted with one or more arrays of thin Geiger Mueller (GM) detectors operated from an external power supply and data processing unit. Survey readings are taken in a step-wise fashion. A video camera and tape recording system are used for video surveys of pipe interiors prior to and during radiological surveys. Pipe Crawler{reg_sign} has potential advantages over the baseline and other technologies in areas of cost, durability, waste minimization, andmore » intrusiveness. Advantages include potentially reduced cost, potential reuse of the pipe system, reduced waste volume, and the ability to manage pipes in place with minimal disturbance to facility operations. Advantages over competing technologies include potentially reduced costs and the ability to perform beta-gamma surveys that are capable of passing regulatory scrutiny for free release of piping systems.« less
In vivo effect of shock-waves on the healing of fractured bone.
Augat, P; Claes, L; Suger, G
1995-10-01
In a controlled animal experiment we attempted to clarify the question of whether there is a stimulating effect of extracorporeal shock-waves on the repair process of fractured long bones. As a fracture model we used an osteotomy in the diaphysis of the ovine tibia and an external fixation device. Shock-wave treatment at two levels of intensity and with four different numbers of applied shocks was performed with an electromagnetic acoustic source. Healing of the osteotomized bone was evaluated by biomechanical and radiological investigations on the whole bone as well as on bone sections from areas of the fracture gap and the periosteal fracture callus. We found a non-significant tendency to deterioration of the fracture healing with increasing shock-wave intensities. The study of treatment parameters led neither to significantly different biomechanical outcomes nor to altered radiological results in comparison to the untreated control group. RELEVANCE:--While we cannot comment upon the effectiveness of extracorporeal shock-waves in the delayed treatment of fractures or pseudarthrosis, our results suggest that shock-waves have no beneficial effect in acute fracture repair.
Shimura, Tsutomu; Yamaguchi, Ichiro; Terada, Hiroshi; Robert Svendsen, Erik; Kunugita, Naoki
2015-05-01
Herein we summarize the public health actions taken to mitigate exposure of the public to radiation after the Fukushima accident that occurred on 11 March 2011 in order to record valuable lessons learned for disaster preparedness. Evacuations from the radiation-affected areas and control of the distribution of various food products contributed to the reduction of external and internal radiation exposure resulting from the Fukushima incident. However, risk communication is also an important issue during the emergency response effort and subsequent phases of dealiing with a nuclear disaster. To assist with their healing process, sound, reliable scientific information should continue to be disseminated to the radiation-affected communities via two-way communication. We will describe the essential public health actions following a nuclear disaster for the early, intermediate and late phases that will be useful for radiological preparedness planning in response to other nuclear or radiological disasters. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
McArthur, Tatum A; Flug, Jonathan A; Restauri, Nicole
The practice of radiology is continually evolving with external pressures increasing the involvement of the radiologist as an integrated member of the multidisciplinary care delivery team and not just image interpreters working in isolation. Radiologists need to be comfortable interacting directly with patients and practicing "patient and family-centered care" and "value-based medicine." Despite this evolving role of the radiologist, medical training and the residency selection process have not significantly adapted to accommodate these new demands. In order to develop and hire radiologists who can excel in this role, the selection and interview process must be adapted to prospectively identify those candidates who can thrive in this changing role. Behavior-based interviewing is a tool that can help identify those candidates who may excel in the future. 1-3 Though there are reports of it being used in the United States medical schools and residency programs across the nation, it has not become a mainstay for medical residency and professional medical interviewing. Copyright © 2017 Elsevier Inc. All rights reserved.
Canbaz, Buket; Cam, N Füsun; Yaprak, Günseli; Candan, Osman
2010-09-01
The surveys of natural gamma-emitting radionuclides in rocks and soils from the Ezine plutonic area were conducted during 2007. Direct dose measurement using a survey meter was carried out simultaneously. The present study, which is part of the survey, analysed the activity concentrations of (238)U, (232)Th and (40)K in granitoid samples from all over the region by HPGe gamma spectrometry. The activity concentrations of (226)Ra ranged from 94 to 637 Bq kg(-1), those of (232)Th ranged from 120 to 601 Bq kg(-1)and those of (40)K ranged from 1074 to 1527 Bq kg(-1) in the analysed rock samples from different parts of the pluton. To evaluate the radiological hazard of the natural radioactivity in the samples, the absorbed dose rate (D), the annual effective dose rate, the radium equivalent activity (Ra(eq)) and the external (H(ex)) hazard index were calculated according to the UNSCEAR 2000 report. The thorium-to-uranium concentration ratios were also estimated.
U.S.-CHINA RADIOLOGICAL SOURCE SECURITY PROJECT: CONTINUING AND EXPANDING BILATERAL COOPERATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Zhixuan; Zhou, Qifu; Yang, Yaoyun
2009-10-07
The successful radiological security cooperation between the U.S. and China to secure at-risk sites near venues of the 2008 Beijing Summer Olympics has led to an expanded bilateral nonproliferation cooperation scope. The U.S. Department of Energy’s National Nuclear Security Administration, the Chinese Atomic Energy Authority and the China Ministry of Environmental Protection are continuing joint efforts to secure radiological sources throughout China under the U.S.-China Peaceful Uses of Nuclear Technology (PUNT) Agreement. Joint cooperation activities include physical security upgrades of sites with International Atomic Energy Agency (IAEA) Category 1 radiological sources, packaging, recovery, and storage of high activity transuranic andmore » beta gamma sources, and secure transportation practices for the movement of recovered sources. Expansion of cooperation into numerous provinces within China includes the use of integrated training workshops that will demonstrate methodologies and best practices between U.S. and Chinese radiological source security and recovery experts. The fiscal year 2009 expanded scope of cooperation will be conducted similar to the 2008 Olympic cooperation with the Global Threat Reduction Initiative taking the lead for the U.S., PUNT being the umbrella agreement, and Los Alamos, Sandia, and Oak Ridge National Laboratories operating as technical working groups. This paper outlines the accomplishments of the joint implementation and training efforts to date and discusses the possible impact on future U.S./China cooperation.« less
Diversity Matters in Academic Radiology: Acknowledging and Addressing Unconscious Bias.
Allen, Brenda J; Garg, Kavita
2016-12-01
To meet challenges related to changing demographics, and to optimize the promise of diversity, radiologists must bridge the gap between numbers of women and historically underrepresented minorities in radiology and radiation oncology as contrasted with other medical specialties. Research reveals multiple ways that women and underrepresented minorities can benefit radiology education, research, and practice. To achieve those benefits, promising practices promote developing and implementing strategies that support diversity as an institutional priority and cultivate shared responsibility among all members to create inclusive learning and workplace environments. Strategies also include providing professional development to empower and equip members to accomplish diversity-related goals. Among topics for professional development about diversity, unconscious bias has shown positive results. Unconscious bias refers to ways humans unknowingly draw upon assumptions about individuals and groups to make decisions about them. Researchers have documented unconscious bias in a variety of contexts and professions, including health care, in which they have studied differential treatment, diagnosis, prescribed care, patient well-being and compliance, physician-patient interactions, clinical decision making, and medical school education. These studies demonstrate unfavorable impacts on members of underrepresented groups and women. Learning about and striving to counteract unconscious bias points to promising practices for increasing the numbers of women and underrepresented minorities in the radiology and radiation oncology workforce. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Körner, Markus; Bernstein, Mark P; Sodickson, Aaron D; Beenen, Ludo F; McLaughlin, Patrick D; Kool, Digna R; Bilow, Ronald M
2016-01-01
In the setting of mass casualty incidents (MCIs), hospitals need to divert from normal routine to delivering the best possible care to the largest number of victims. This should be accomplished by activating an established hospital disaster management plan (DMP) known to all staff through prior training drills. Over the recent decades, imaging has increasingly been used to evaluate critically ill patients. It can also be used to increase the accuracy of triaging MCI victims, since overtriage (falsely higher triage category) and undertriage (falsely lower triage category) can severely impact resource availability and mortality rates, respectively. This article emphasizes the importance of including the radiology department in hospital preparations for a MCI and highlights factors expected to influence performance during hospital DMP activation including issues pertinent to effective simulation, such as establishing proper learning objectives. After-action reviews including performance evaluation and debriefing on issues are invaluable following simulation drills and DMP activation, in order to improve subsequent preparedness. Historically, most hospital DMPs have not adequately included radiology department operations, and they have not or to a little extent been integrated in the DMP activation simulation. This article aims to increase awareness of the need for radiology department engagement in order to increase radiology department preparedness for DMP activation after a MCI occurs. PMID:26781837
Assessing the impact of a radiology information management system in the emergency department
NASA Astrophysics Data System (ADS)
Redfern, Regina O.; Langlotz, Curtis P.; Lowe, Robert A.; Horii, Steven C.; Abbuhl, Stephanie B.; Kundel, Harold L.
1998-07-01
To evaluate a conventional radiology image management system, by investigating information accuracy, and information delivery. To discuss the customization of a picture archival and communication system (PACS), integrated radiology information system (RIS) and hospital information system (HIS) to a high volume emergency department (ED). Materials and Methods: Two data collection periods were completed. After the first data collection period, a change in work rules was implemented to improve the quality of data in the image headers. Data from the RIS, the ED information system, and the HIS as well as observed time motion data were collected for patients admitted to the ED. Data accuracy, patient waiting times, and radiology exam information delivery were compared. Results: The percentage of examinations scheduled in the RIS by the technologists increased from 0% (0 of 213) during the first period to 14% (44 of 317) during the second (p less than 0.001). The percentage of images missing identification numbers decreased from 36% (98 of 272) during the first data collection period to 10% (56 of 562) during the second period (p less than 0.001). Conclusions: Radiologic services in a high-volume ED, requiring rapid service, present important challenges to a PACS system. Strategies can be implemented to improve accuracy and completeness of the data in PACS image headers in such an environment.
Organizational flexibility as a strategic option: fostering dynamic capabilities of hospitals.
Dias, Casimiro; Escoval, Ana
2014-01-01
The main purpose of this article is to examine how the internal and external dimensions of organizational flexibility impact hospital performance. Results reveal that matching internal and external flexibilities contributes to the development of capabilities to adopt new strategic options. Such interactions have a significant impact in terms of hospital performance. A cluster of dynamic hospitals, which is characterised by high levels of both internal and external flexibilities, (instead of that have high levels of both internal and external flexibilities) was found to have the double level of performance compared with other clusters. The implications for research and managerial practice are discussed. Copyright © 2014 Longwoods Publishing.
Pregnancy and Radiation Protection
NASA Astrophysics Data System (ADS)
Gerogiannis, J.; Stefanoyiannis, A. P.
2010-01-01
Several modalities are currently utilized for diagnosis and therapy, by appropriate application of x-rays. In diagnostic radiology, interventional radiology, radiotherapy, interventional cardiology, nuclear medicine and other specialties radiation protection of a pregnant woman as a patient, as well as a member of the operating personnel, is of outmost importance. Based on radiation risk, the termination of pregnancy is not justified if foetal doses are below 100 mGy. For foetal doses between 100 and 500 mGy, a decision is reached on a case by case basis. In Diagnostic Radiology, when a pregnant patient takes an abdomen CT, then an estimation of the foetus' dose is necessary. However, it is extremely rare for the dose to be high enough to justify an abortion. Radiographs of the chest and extremities can be done at any period of pregnancy, provided that the equipment is functioning properly. Usually, the radiation risk is lower than the risk of not undergoing a radiological examination. Radiation exposure in uterus from diagnostic radiological examinations is unlikely to result in any deleterious effect on the child, but the possibility of a radiation-induced effect can not be entirely ruled out. The effects of exposure to radiation on the foetus depend on the time of exposure, the date of conception and the absorbed dose. Finally, a pregnant worker can continue working in an x-ray department, as long as there is reasonable assurance that the foetal dose can be kept below 1 mGy during the pregnancy. Nuclear Medicine diagnostic examinations using short-lived radionuclides can be used for pregnant patient. Irradiation of the foetus results from placental transfer and distribution of radiopharmaceuticals in the foetal tissues, as well as from external irradiation from radioactivity in the mother's organ and tissues. As a rule, a pregnant patient should not undergo therapy with radionuclide, unless it is crucial for her life. In Radiotherapy, the patient, treating oncologist, other team and family members should carefully discuss for the decision of abortion. Important factors must be considered such as the stage and aggressiveness of the tumour, the location of the tumour, the stage of pregnancy, various therapies etc.
Pregnancy and Radiation Protection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerogiannis, J.; Stefanoyiannis, A. P.
Several modalities are currently utilized for diagnosis and therapy, by appropriate application of x-rays. In diagnostic radiology, interventional radiology, radiotherapy, interventional cardiology, nuclear medicine and other specialties radiation protection of a pregnant woman as a patient, as well as a member of the operating personnel, is of outmost importance. Based on radiation risk, the termination of pregnancy is not justified if foetal doses are below 100 mGy. For foetal doses between 100 and 500 mGy, a decision is reached on a case by case basis. In Diagnostic Radiology, when a pregnant patient takes an abdomen CT, then an estimation ofmore » the foetus' dose is necessary. However, it is extremely rare for the dose to be high enough to justify an abortion. Radiographs of the chest and extremities can be done at any period of pregnancy, provided that the equipment is functioning properly. Usually, the radiation risk is lower than the risk of not undergoing a radiological examination. Radiation exposure in uterus from diagnostic radiological examinations is unlikely to result in any deleterious effect on the child, but the possibility of a radiation-induced effect can not be entirely ruled out. The effects of exposure to radiation on the foetus depend on the time of exposure, the date of conception and the absorbed dose. Finally, a pregnant worker can continue working in an x-ray department, as long as there is reasonable assurance that the foetal dose can be kept below 1 mGy during the pregnancy. Nuclear Medicine diagnostic examinations using short-lived radionuclides can be used for pregnant patient. Irradiation of the foetus results from placental transfer and distribution of radiopharmaceuticals in the foetal tissues, as well as from external irradiation from radioactivity in the mother's organ and tissues. As a rule, a pregnant patient should not undergo therapy with radionuclide, unless it is crucial for her life. In Radiotherapy, the patient, treating oncologist, other team and family members should carefully discuss for the decision of abortion. Important factors must be considered such as the stage and aggressiveness of the tumour, the location of the tumour, the stage of pregnancy, various therapies etc.« less
Baskin-Sommers, Arielle R; Krusemark, Elizabeth A; Curtin, John J; Lee, Christopher; Vujnovich, Aleice; Newman, Joseph P
2014-02-01
The P3 amplitude reduction is one of the most common correlates of externalizing. However, few studies have used experimental manipulations designed to challenge different cognitive functions in order to clarify the processes that impact this reduction. To examine factors moderating P3 amplitude in trait externalizing, we administered an n-back task that manipulated cognitive control demands, working memory load, and incentives to a sample of male offenders. Offenders with high trait externalizing scores did not display a global reduction in P3 amplitude. Rather, the negative association between trait externalizing and P3 amplitude was specific to trials involving inhibition of a dominant response during infrequent stimuli, in the context of low working memory load, and incentives for performance. In addition, we discuss the potential implications of these findings for externalizing-related psychopathologies. The results complement and expand previous work on the process-level dysfunction contributing to externalizing-related deficits in P3. Copyright © 2013 Elsevier B.V. All rights reserved.
Functional Impairments in Children with ADHD: Unique Effects of Age and Comorbid Status
ERIC Educational Resources Information Center
Booster, Genery D.; DuPaul, George J.; Eiraldi, Ricardo; Power, Thomas J.
2012-01-01
Objective: Children with ADHD and comorbid disorders display poorer overall functioning compared with children with ADHD alone, though little research has examined the differential impact of externalizing versus internalizing comorbidities. Method: This study examined the impact of internalizing and externalizing comorbidities on the academic and…
Estimates of External Validity Bias When Impact Evaluations Select Sites Nonrandomly
ERIC Educational Resources Information Center
Bell, Stephen H.; Olsen, Robert B.; Orr, Larry L.; Stuart, Elizabeth A.
2016-01-01
Evaluations of educational programs or interventions are typically conducted in nonrandomly selected samples of schools or districts. Recent research has shown that nonrandom site selection can yield biased impact estimates. To estimate the external validity bias from nonrandom site selection, we combine lists of school districts that were…
Data requirements for valuing externalities: The role of existing permitting processes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, A.D.; Baechler, M.C.; Callaway, J.M.
1990-08-01
While the assessment of externalities, or residual impacts, will place new demands on regulators, utilities, and developers, existing processes already require certain data and information that may fulfill some of the data needs for externality valuation. This paper examines existing siting, permitting, and other processes and highlights similarities and differences between their data requirements and the data required to value environmental externalities. It specifically considers existing requirements for siting new electricity resources in Oregon and compares them with the information and data needed to value externalities for such resources. This paper also presents several observations about how states can takemore » advantage of data acquired through processes already in place as they move into an era when externalities are considered in utility decision-making. It presents other observations on the similarities and differences between the data requirements under existing processes and those for valuing externalities. This paper also briefly discusses the special case of cumulative impacts. And it presents recommendations on what steps to take in future efforts to value externalities. 35 refs., 2 tabs.« less
Bedi, Pallavi; Chalmers, James D; Goeminne, Pieter C; Mai, Cindy; Saravanamuthu, Pira; Velu, Prasad Palani; Cartlidge, Manjit K; Loebinger, Michael R; Jacob, Joe; Kamal, Faisal; Schembri, Nicola; Aliberti, Stefano; Hill, Uta; Harrison, Mike; Johnson, Christopher; Screaton, Nicholas; Haworth, Charles; Polverino, Eva; Rosales, Edmundo; Torres, Antoni; Benegas, Michael N; Rossi, Adriano G; Patel, Dilip; Hill, Adam T
2018-05-01
The goal of this study was to develop a simplified radiological score that could assess clinical disease severity in bronchiectasis. The Bronchiectasis Radiologically Indexed CT Score (BRICS) was devised based on a multivariable analysis of the Bhalla score and its ability in predicting clinical parameters of severity. The score was then externally validated in six centers in 302 patients. A total of 184 high-resolution CT scans were scored for the validation cohort. In a multiple logistic regression model, disease severity markers significantly associated with the Bhalla score were percent predicted FEV 1 , sputum purulence, and exacerbations requiring hospital admission. Components of the Bhalla score that were significantly associated with the disease severity markers were bronchial dilatation and number of bronchopulmonary segments with emphysema. The BRICS was developed with these two parameters. The receiver operating-characteristic curve values for BRICS in the derivation cohort were 0.79 for percent predicted FEV 1 , 0.71 for sputum purulence, and 0.75 for hospital admissions per year; these values were 0.81, 0.70, and 0.70, respectively, in the validation cohort. Sputum free neutrophil elastase activity was significantly elevated in the group with emphysema on CT imaging. A simplified CT scoring system can be used as an adjunct to clinical parameters to predict disease severity in patients with idiopathic and postinfective bronchiectasis. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Singh, Vijay K; Newman, Victoria L; Seed, Thomas M
2015-01-01
One of the greatest national security threats to the United States is the detonation of an improvised nuclear device or a radiological dispersal device in a heavily populated area. As such, this type of security threat is considered to be of relatively low risk, but one that would have an extraordinary high impact on health and well-being of the US citizenry. Psychological counseling and medical assessments would be necessary for all those significantly impacted by the nuclear/radiological event. Direct medical interventions would be necessary for all those individuals who had received substantial radiation exposures (e.g., >1 Gy). Although no drugs or products have yet been specifically approved by the United States Food and Drug Administration (US FDA) to treat the effects of acute radiation syndrome (ARS), granulocyte colony-stimulating factor (G-CSF), granulocyte macrophage colony-stimulating factor (GM-CSF), and pegylated G-CSF have been used off label for treating radiation accident victims. Recent threats of terrorist attacks using nuclear or radiologic devices makes it imperative that the medical community have up-to-date information and a clear understanding of treatment protocols using therapeutically effective recombinant growth factors and cytokines such as G-CSF and GM-CSF for patients exposed to injurious doses of ionizing radiation. Based on limited human studies with underlying biology, we see that the recombinants, G-CSF and GM-CSF appear to have modest, but significant medicinal value in treating radiation accident victims. In the near future, the US FDA may approve G-CSF and GM-CSF as ‘Emergency Use Authorization’ (EUA) for managing radiation-induced aplasia, an ARS-related pathology. In this article, we review the status of growth factors for the treatment of radiological/nuclear accident victims.
Katsenis, Dimitris; Athanasiou, Vasilis; Vasilis, Athanasiou; Megas, Panayiotis; Panayiotis, Megas; Tyllianakis, Minos; Minos, Tillianakis; Lambiris, Elias
2005-04-01
To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.
Externally resonated linear microvibromotor for microassembly
NASA Astrophysics Data System (ADS)
Saitou, Kazuhiro; Wou, Soungjin J.
1998-10-01
A new design of a linear micro vibromotor for on-substrate fine positioning of micro-scale components is presented where a micro linear slider is actuated by vibratory impacts exerted by micro cantilever impacters. These micro cantilever impacters are selectively resonated by shaking the entire substrate with a piezoelectric vibrator, requiring no need for built-in driving mechanisms such as electrostatic comb actuators as reported previously. This selective resonance of the micro cantilever impacters via an external vibration energy field provides with a very simple means of controlling forward and backward motion of the micro linear slider, facilitating assembly and disassembly of a micro component on a substrate. The double-V beam suspension design is employed in the micro cantilever impacters for larger displacement in the lateral direction while achieving higher stiffness in the transversal direction. An analytical model of the device is derived in order to obtain, through the Simulated Annealing algorithm, an optimal design which maximizes translation speed of the linear slider at desired external input frequencies. Prototypes of the externally-resonated linear micro vibromotor are fabricated using the three-layer polysilicon surface micro machining process provided by the MCNC MUMPS service.
Baresel, Christian; Dalgren, Lena; Almemark, Mats; Lazic, Aleksandra
2016-01-01
Wastewater reclamation will be a significant part of future water management and the environmental assessment of various treatment systems to reuse wastewater has become an important research field. The secondary treatment process and sludge handling on-site are, especially, electricity demanding processes due to aeration, pumping, mixing, dewatering, etc. used for operation and are being identified as the main contributor for many environmental impacts. This study discusses how the environmental performance of reuse treatment systems may be influenced by surrounding conditions. This article illustrates and discusses the importance of factors commonly treated as externalities and as such not being included in optimization strategies of reuse systems, but that are necessary to environmentally assess wastewater reclamation systems. This is illustrated by two up-stream and downstream processes; electricity supply and the use of sludge as fertilizer commonly practiced in regions considered for wastewater reclamation. The study shows that external conditions can have a larger impact on the overall environmental performance of reuse treatment systems than internal optimizations could compensate for. These results imply that a more holistic environmental assessment of reuse schemes could provide less environmental impacts as externalities could be included in measures to reduce the overall impacts.
Ziegler, Christoph M; Klimowicz, Thomas R
2013-01-01
An increasing number of different types of commercial cone-beam computed tomography (CBCT) devices are available for three-dimensional (3D) imaging in the field of dental and maxillofacial radiology. When removing impacted or supernumerary teeth, surgical teams often operate adjacent significant anatomical structures such as nerves, vessels, adjacent teeth roots, and paranasal sinuses. It is therefore important to choose the appropriate surgical approach to avoid iatrogenic damage to the essential anatomical neighbouring structures. CBCT, also called digital volume tomography (DVT), can visualize impacted and supernumerary teeth in all standard planes, as well as multisectional 3D views. These devices have shown to be highly beneficial in the assessment of small bony lesions and maxillofacial injuries. However, it is still necessary to determine the effectiveness of such devices in the assessment of impacted and supernumerary teeth, in comparison to the conventional radiological methods of intraoral X-rays and panoramic X-rays. During a period of 2 years, a total of 61 patients of whom majority had impacted teeth or supernumerary elements in the frontal maxillary region were studied with CBCT and treated at the St. Olavs University Hospital. Patients were referred to our Department of Oral and Maxillofacial Surgery with both conventional and digital intraoral X-rays and/or panoramic X-rays. None had any acute infections or odontogenic abscesses, and most presented with asymptomatic impacted tooth. A comparison between the preoperative conventional and the CBCT images, the resulting diagnoses, and the intraoperative findings as "gold standard" were made and recorded in a compiled scoring sheet. The objects of interest were researched with the magnification method. Each patient was identified only with a patient number. In contrast to the conventional X-rays, the pre-surgical evaluation with the CBCT revealed detailed imaging of significant anatomical structures and objects of interest, with highly accurate anatomical and morphologic imaging, when compared to the intraoperative findings. Furthermore, no diagnostic problems, in relation to the anatomical localization, occurred preoperatively. The CBCT provides true and precise anatomical information with high surgical predictability without distortion or artefacts, and is superior to conventional radiography. It enables more time-efficient surgeries and reduces costs and surgical complications.
Lu, Lingbo; Li, Jingshan; Gisler, Paula
2011-06-01
Radiology tests, such as MRI, CT-scan, X-ray and ultrasound, are cost intensive and insurance pre-approvals are necessary to get reimbursement. In some cases, tests may be denied for payments by insurance companies due to lack of pre-approvals, inaccurate or missing necessary information. This can lead to substantial revenue losses for the hospital. In this paper, we present a simulation study of a centralized scheduling process for outpatient radiology tests at a large community hospital (Central Baptist Hospital in Lexington, Kentucky). Based on analysis of the central scheduling process, a simulation model of information flow in the process has been developed. Using such a model, the root causes of financial losses associated with errors and omissions in this process were identified and analyzed, and their impacts were quantified. In addition, "what-if" analysis was conducted to identify potential process improvement strategies in the form of recommendations to the hospital leadership. Such a model provides a quantitative tool for continuous improvement and process control in radiology outpatient test scheduling process to reduce financial losses associated with process error. This method of analysis is also applicable to other departments in the hospital.
Health impact of external funding for HIV, tuberculosis and malaria: systematic review
de Jongh, Thyra E; Harnmeijer, Joanne H; Atun, Rifat; Korenromp, Eline L; Zhao, Jinkou; Puvimanasinghe, John; Baltussen, Rob
2014-01-01
Background Since 2002, development assistance for health has substantially increased, especially investments for HIV, tuberculosis (TB) and malaria control. We undertook a systematic review to assess and synthesize the existing evidence in the scientific literature on the health impacts of these investments. Methods and findings We systematically searched databases for peer-reviewed and grey literature, using tailored search strategies. We screened studies for study design and relevance, using predefined inclusion criteria, and selected those that enabled us to link health outcomes or impact to increased external funding. For all included studies, we recorded dataset and study characteristics, health outcomes and impacts. We analysed the data using a causal-chain framework to develop a narrative summary of the published evidence. Thirteen articles, representing 11 individual studies set in Africa and Asia reporting impacts on HIV, tuberculosis and malaria, met the inclusion criteria. Only two of these studies documented the entire causal-chain spanning from funding to programme scale-up, to outputs, outcomes and impacts. Nonetheless, overall we find a positive correlation between consecutive steps in the causal chain, suggesting that external funds for HIV, tuberculosis and malaria programmes contributed to improved health outcomes and impact. Conclusions Despite the large number of supported programmes worldwide and despite an abundance of published studies on HIV, TB and malaria control, we identified very few eligible studies that adequately demonstrated the full process by which external funding has been translated to health impact. Most of these studies did not move beyond demonstrating statistical association, as opposed to contribution or causation. We thus recommend that funding organizations and researchers increase the emphasis on ensuring data capture along the causal pathway to demonstrate effect and contribution of external financing. The findings of these comprehensive and rigorously conducted impact evaluations should also be made publicly accessible. PMID:23921987
Health impact of external funding for HIV, tuberculosis and malaria: systematic review.
de Jongh, Thyra E; Harnmeijer, Joanne H; Atun, Rifat; Korenromp, Eline L; Zhao, Jinkou; Puvimanasinghe, John; Baltussen, Rob
2014-08-01
Since 2002, development assistance for health has substantially increased, especially investments for HIV, tuberculosis (TB) and malaria control. We undertook a systematic review to assess and synthesize the existing evidence in the scientific literature on the health impacts of these investments. We systematically searched databases for peer-reviewed and grey literature, using tailored search strategies. We screened studies for study design and relevance, using predefined inclusion criteria, and selected those that enabled us to link health outcomes or impact to increased external funding. For all included studies, we recorded dataset and study characteristics, health outcomes and impacts. We analysed the data using a causal-chain framework to develop a narrative summary of the published evidence. Thirteen articles, representing 11 individual studies set in Africa and Asia reporting impacts on HIV, tuberculosis and malaria, met the inclusion criteria. Only two of these studies documented the entire causal-chain spanning from funding to programme scale-up, to outputs, outcomes and impacts. Nonetheless, overall we find a positive correlation between consecutive steps in the causal chain, suggesting that external funds for HIV, tuberculosis and malaria programmes contributed to improved health outcomes and impact. Despite the large number of supported programmes worldwide and despite an abundance of published studies on HIV, TB and malaria control, we identified very few eligible studies that adequately demonstrated the full process by which external funding has been translated to health impact. Most of these studies did not move beyond demonstrating statistical association, as opposed to contribution or causation. We thus recommend that funding organizations and researchers increase the emphasis on ensuring data capture along the causal pathway to demonstrate effect and contribution of external financing. The findings of these comprehensive and rigorously conducted impact evaluations should also be made publicly accessible. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2013; all rights reserved.
Kortekangas, Tero H J; Pakarinen, Harri J; Savola, Olli; Niinimäki, Jaakko; Lepojärvi, Sannamari; Ohtonen, Pasi; Flinkkilä, Tapio; Ristiniemi, Jukka
2014-10-01
This study compared mid-term functional and radiologic results of syndesmotic transfixation with no fixation in supination external rotation (SER) ankle fractures with intraoperatively confirmed syndesmosis disruption. Our hypothesis was that early-stage good functional results would remain and unfixed syndesmosis disruption in SER IV ankle fractures would not lead to an increased incidence of osteoarthritis. A prospective study of 140 operatively treated patients with Lauge-Hansen SER IV (Weber B) ankle fractures was performed. After bony fixation, the 7.5-Nm standardized external rotation stress test for both ankles was performed under fluoroscopy. A positive stress examination was defined as a difference of more than 2 mm side-to-side in the tibiotalar or tibiofibular clear spaces on mortise radiographs. The patients were randomized to either syndesmotic screw fixation (13 patients) or no syndesmotic fixation (11 patients). After a minimum of 4 years of follow-up (mean, 58 months), ankle function and pain (Olerud-Molander, a 100-mm visual analogue scale [VAS] for ankle function and pain) and quality of life (RAND-36) of all 24 patients were assessed. Ankle joint congruity and osteoarthritis were assessed using mortise and lateral projection plain weight-bearing radiographs and magnetic resonance imaging (MRI; 3T) scans. Improvement in Olerud-Molander score, VAS, and RAND-36 showed no significant difference between groups during the follow-up. In the syndesmotic transfixation group, improvements in all functional parameters and pain measurements were not significant, whereas in the group without syndesmotic fixation, the Olerud-Molander score improved from 84 to 93 (P = .007) and the pain (VAS) score improved from 11 to 4 (P = .038) from 1 year to last follow-up. X-ray or MRI imaging showed no difference between groups at the last follow-up visit. With the numbers available, no significant difference in functional outcome or radiologic findings could be detected between syndesmosis transfixation and no-fixation patients with SER IV ankle fracture after a minimum of 4 years of follow-up. Level II, prospective comparative study. © The Author(s) 2014.
An uncertainty analysis of air pollution externalities from road transport in Belgium in 2010.
Int Panis, L; De Nocker, L; Cornelis, E; Torfs, R
2004-12-01
Although stricter standards for vehicles will reduce emissions to air significantly by 2010, a number of problems will remain, especially related to particulate concentrations in cities, ground-level ozone, and CO(2). To evaluate the impacts of new policy measures, tools need to be available that assess the potential benefits of these measures in terms of the vehicle fleet, fuel choice, modal choice, kilometers driven, emissions, and the impacts on public health and related external costs. The ExternE accounting framework offers the most up to date and comprehensive methodology to assess marginal external costs of energy-related pollutants. It combines emission models, air dispersion models at local and regional scales with dose-response functions and valuation rules. Vito has extended this accounting framework with data and models related to the future composition of the vehicle fleet and transportation demand to evaluate the impact of new policy proposals on air quality and aggregated (total) external costs by 2010. Special attention was given to uncertainty analysis. The uncertainty for more than 100 different parameters was combined in Monte Carlo simulations to assess the range of possible outcomes and the main drivers of these results. Although the impacts from emission standards and total fleet mileage look dominant at first, a number of other factors were found to be important as well. This includes the number of diesel vehicles, inspection and maintenance (high-emitter cars), use of air conditioning, and heavy duty transit traffic.
Martinez-Sanchez, Veronica; Levis, James W; Damgaard, Anders; DeCarolis, Joseph F; Barlaz, Morton A; Astrup, Thomas F
2017-03-21
The development of sustainable solid waste management (SWM) systems requires consideration of both economic and environmental impacts. Societal life-cycle costing (S-LCC) provides a quantitative framework to estimate both economic and environmental impacts, by including "budget costs" and "externality costs". Budget costs include market goods and services (economic impact), whereas externality costs include effects outside the economic system (e.g., environmental impact). This study demonstrates the applicability of S-LCC to SWM life-cycle optimization through a case study based on an average suburban U.S. county of 500 000 people generating 320 000 Mg of waste annually. Estimated externality costs are based on emissions of CO 2 , CH 4 , N 2 O, PM 2.5 , PM 10 , NO x , SO 2 , VOC, CO, NH 3 , Hg, Pb, Cd, Cr (VI), Ni, As, and dioxins. The results indicate that incorporating S-LCC into optimized SWM strategy development encourages the use of a mixed waste material recovery facility with residues going to incineration, and separated organics to anaerobic digestion. Results are sensitive to waste composition, energy mix and recycling rates. Most of the externality costs stem from SO 2 , NO x , PM 2.5 , CH 4 , fossil CO 2 , and NH 3 emissions. S-LCC proved to be a valuable tool for policy analysis, but additional data on key externality costs such as organic compounds emissions to water would improve future analyses.
Assessment of occupational exposure in a granite quarry and processing factory.
Tejado, J J; Guillén, J; Baeza, A
2016-09-01
Workers in the granite industry face an occupational hazard: silicosis due to the crystalline silica present in inhalable dust. As granite can also present a variable, and occasionally significant, content of naturally occurring radionuclides, they may also face a radiological hazard. In order to assess the risk, a granite industry with a quarry and processing factory was selected to assess the occupational exposure. Three main potential pathways were observed: external irradiation, inhalation of granite dust, and radon exposure. The external dose rate was similar to that in a nearby farming area. A slight increment (0.016-0.076 mSv yr -1 ) was observed in the quarry and stockpile, due to quarry faces and granite blocks. The effective dose due to granite dust inhalation was 0.182 ± 0.009 mSv yr -1 in the worst case scenario (3 mg m -3 dust load in air and no use of filter masks). Thus, the mean value of the effective dose from these two pathways was 0.26 mSv yr -1 , lower than the reference level of 1 mSv yr -1 for the general population. The annual mean value of radon concentration in the indoor air was 33 Bq m -3 . However, during granite processing works the radon concentration can increase up to 216 Bq m -3 , due to mechanical operations (sawing, polishing, sanding, etc). This radon concentration was below the 600 Bq m -3 reference level for action in working places. Therefore, workers in this granite factory face no significant additional radiological exposure, and no-one needs to be designated as occupationally exposed and subject to individual dosimetry.
ERIC Educational Resources Information Center
Seema, Riin; Udam, Maiki; Mattisen, Heli; Lauri, Liia
2017-01-01
The purpose of this article is to provide an overview of how the employees of higher education institutions perceive the impact of external evaluations. The study was conducted using the concurrent mixed method and involved 361 employees from Estonian universities and professional higher education institutions. The results indicated that…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farina, R.; Brandao-Mello, C.E.; Oliveira, A.R.
In September 1987, the Goiania radiological accident involving a source of {sup 137}Cs culminated in about 140 victims who presented internal and/or external contamination and/or external exposure to radiation and/or radiation burns. Internal contamination was verified through analysis of urine and fecal samples. Internal contamination was also evaluated by measurements performed at the whole-body counter installed in Goiania in November 1987. To enhance the decorporation of 137Cs, patients were treated with the following: (1) Prussian Blue, oral administration, in 46 patients; (2) diuretics, oral administration, in 17 patients; (3) induced perspiration, increasing {sup 137}Cs elimination. These procedures were done undermore » rigorous clinical evaluation and considering the data from assay of excreta and data obtained from the whole-body counter. The doses of Prussian Blue exceeded about 6.5 times the dose previously indicated in the literature. It was the first time diuretics were used in humans to treat {sup 137}Cs internal contamination. The results of these procedures are discussed.« less
Cystic lesion around the hip joint
Yukata, Kiminori; Nakai, Sho; Goto, Tomohiro; Ikeda, Yuichi; Shimaoka, Yasunori; Yamanaka, Issei; Sairyo, Koichi; Hamawaki, Jun-ichi
2015-01-01
This article presents a narrative review of cystic lesions around the hip and primarily consists of 5 sections: Radiological examination, prevalence, pathogenesis, symptoms, and treatment. Cystic lesions around the hip are usually asymptomatic but may be observed incidentally on imaging examinations, such as computed tomography and magnetic resonance imaging. Some cysts may enlarge because of various pathological factors, such as trauma, osteoarthritis, rheumatoid arthritis, or total hip arthroplasty (THA), and may become symptomatic because of compression of surrounding structures, including the femoral, obturator, or sciatic nerves, external iliac or common femoral artery, femoral or external iliac vein, sigmoid colon, cecum, small bowel, ureters, and bladder. Treatment for symptomatic cystic lesions around the hip joint includes rest, nonsteroidal anti-inflammatory drug administration, needle aspiration, and surgical excision. Furthermore, when these cysts are associated with osteoarthritis, rheumatoid arthritis, and THA, primary or revision THA surgery will be necessary concurrent with cyst excision. Knowledge of the characteristic clinical appearance of cystic masses around the hip will be useful for determining specific diagnoses and treatments. PMID:26495246
Determination of naturally radioactive elements in chalk sticks by means of gamma spectroscopy
NASA Astrophysics Data System (ADS)
Abd El-Wahab, Magda; Morsy, Zeinab; El-Faramawy, Nabil
2010-04-01
The radiation hazards due to ingestion of chalkboard dust were investigated. Sixteen samples from three different origin fabricates were used. The estimation of radiation hazard indices were based on the evaluation of the concentration activities of the natural radionuclides 238U, 232Th and 40K. The radium equivalent activity, external hazard index, internal hazard index and the annual dose equivalent associated with the radionuclides were calculated and compared with international recommended values to assess the radiation hazard. The values of internal and external radiation hazard indices were found to be less than unity. The annual effective dose rate obtained, E eff, and the annual gonadal dose equivalent (AGDE) are found to be less than the limit of the doses recommended by the International Commission on Radiological Protection for the general public. The analytical results show that besides the main calcium content, some toxic elements, S, Mo and Pb and Ni and Pb, in the Egyptian and imported chalk stocks, respectively, existed.
Determination of naturally radioactive elements in chalk sticks by means of gamma spectroscopy
NASA Astrophysics Data System (ADS)
El-Wahab, Magda Abd; Morsy, Zeinab; El-Faramawy, Nabil
The radiation hazards due to ingestion of chalkboard dust were investigated. Sixteen samples from three different origin fabricates were used. The estimation of radiation hazard indices were based on the evaluation of the concentration activities of the natural radionuclides 238U, 232Th and 40K. The radium equivalent activity, external hazard index, internal hazard index and the annual dose equivalent associated with the radionuclides were calculated and compared with international recommended values to assess the radiation hazard. The values of internal and external radiation hazard indices were found to be less than unity. The annual effective dose rate obtained, Eeff, and the annual gonadal dose equivalent (AGDE) are found to be less than the limit of the doses recommended by the International Commission on Radiological Protection for the general public. The analytical results show that besides the main calcium content, some toxic elements, S, Mo and Pb and Ni and Pb, in the Egyptian and imported chalk stocks, respectively, existed.
Emergency percutaneous treatment in surgical bile duct injury.
Carrafiello, Gianpaolo; Laganà, Domenico; Dizonno, Massimiliano; Ianniello, Andrea; Cotta, Elisa; Dionigi, Gianlorenzo; Dionigi, Renzo; Fugazzola, Carlo
2008-09-01
The aim of this study is to evaluate the efficacy of emergency percutaneous treatment in patients with surgical bile duct injury (SBDI). From May 2004 to May 2007, 11 patients (five men, six women; age range 26-80 years; mean age 58 years) with a critical clinical picture (severe jaundice, bile peritonitis, septic state) due to SBDI secondary to surgical or laparoscopic procedures were treated by percutaneous procedures. We performed four ultrasound-guided percutaneous drainages, four external-internal biliary drainages, one bilioplasty, and two plastic biliary stenting after 2 weeks of external-internal biliary drainage placement. All procedures had 100% technical success with no complications. The clinical emergencies resolved in 3-4 days in 100% of cases. All patients had a benign clinical course, and reoperation was avoided in 100% of cases. Interventional radiological procedures are effective in the emergency management of SBDI since they are minimally invasive and have a high success rate and a low incidence of complications compared to the more complex and dangerous surgical or laparoscopic options.
Lentiform fork sign: a magnetic resonance finding in a case of acute metabolic acidosis.
Grasso, Daniela; Borreggine, Carmela; Perfetto, Francesco; Bertozzi, Vincenzo; Trivisano, Marina; Specchio, Luigi Maria; Grilli, Gianpaolo; Macarini, Luca
2014-06-01
We report a 33 year-old woman addicted to chronic unspecified solvents abuse with stupor, respiratory disorders, tetraplegia and severe metabolic acidosis. On admission an unenhanced cranial CT scan showed symmetrical hypodensities of both lentiform nuclei. MR imaging performed 12 hours after stupor demonstrates bilateral putaminal hemorrhagic necrosis, bilateral external capsule, corona radiata and deep cerebellar hyperintensities with right cingulate cortex involvement. DWI reflected bilateral putaminal hyperintensities with restricted water diffusion as to citotoxic edema and development of vasogenic edema in the external capsule recalling a fork. On day twenty, after specific treatments MRI demonstrated a bilateral putaminal marginal enhancement. Bilateral putaminal necrosis is a characteristic but non-specific radiological finding of methanol poisoning. Lentiform Fork sign is a rare MRI finding reported in literature in 22 patients with various conditions characterized by metabolic acidosis. Vasogenic edema may be due to the differences in metabolic vulnerability between neurons and astrocytes. We postulate that metabolic acidosis could have an important role to generate this sign.
Righi, Serena; Lucialli, Patrizia; Pollini, Elisa
2014-03-01
This paper presents the results of a study of radiological impacts related to the shipment of fertilisers to and from the commercial port of Ravenna (NE Italy). In particular, the effective doses to the port workers and members of the population surrounding the port area have been estimated. The study has included different types of measurement and assessment. First, the natural radioactivity of different fertilisers moving through the port has been determined: (40)K, (226)Ra, (210)Pb, (228)Ra and (228)Th concentrations have been analysed using γ-ray spectrometry, while (238)U and (232)Th concentrations have been determined by ICP-MS. At the same time, a dose rate meter and electret ion chambers were used to measure the external irradiation and the radon concentrations, respectively. Then, air pollutant dispersion models have been applied in order to assess particulate matter concentration in the port site and the surrounding residential areas, and consequently the inhalation doses. Finally, the annual effective doses to workers and local residents have been estimated. The effective doses to workers and the population have been estimated to be 0.9 mSv yr(-1) and 0.07 μSv yr(-1), respectively.
Informatics in radiology (infoRAD): A complete continuous-availability PACS archive server.
Liu, Brent J; Huang, H K; Cao, Fei; Zhou, Michael Z; Zhang, Jianguo; Mogel, Greg
2004-01-01
The operational reliability of the picture archiving and communication system (PACS) server in a filmless hospital environment is always a major concern because server failure could cripple the entire PACS operation. A simple, low-cost, continuous-availability (CA) PACS archive server was designed and developed. The server makes use of a triple modular redundancy (TMR) system with a simple majority voting logic that automatically identifies a faulty module and removes it from service. The remaining two modules continue normal operation with no adverse effects on data flow or system performance. In addition, the server is integrated with two external mass storage devices for short- and long-term storage. Evaluation and testing of the server were conducted with laboratory experiments in which hardware failures were simulated to observe recovery time and the resumption of normal data flow. The server provides maximum uptime (99.999%) for end users while ensuring the transactional integrity of all clinical PACS data. Hardware failure has only minimal impact on performance, with no interruption of clinical data flow or loss of data. As hospital PACS become more widespread, the need for CA PACS solutions will increase. A TMR CA PACS archive server can reliably help achieve CA in this setting. Copyright RSNA, 2004
Effective dose in the manufacturing process of rutile covered welding electrodes.
Herranz, M; Rozas, S; Pérez, C; Idoeta, R; Núñez-Lagos, R; Legarda, F
2013-03-01
Shielded metal arc welding using covered electrodes is the most common welding process. Sometimes the covering contains naturally occurring radioactive materials (NORMs). In Spain the most used electrodes are those covered with rutile mixed with other materials. Rutile contains some detectable natural radionuclides, so it can be considered a NORM. This paper mainly focuses on the use of MCNP (Monte Carlo N-Particle Transport Code) as a predictive tool to obtain doses in a factory which produces this type of electrode and assess the radiological impact in a specific facility after estimating the internal dose.To do this, in the facility, areas of highest radiation and positions of workers were identified, radioactive content of rutile and rutile covered electrodes was measured, and, considering a worst possible scenario, external dose at working points has been calculated using MCNP. This procedure has been validated comparing the results obtained with those from a pressurised ionisation chamber and TLD dosimeters. The internal dose has been calculated using DCAL (dose and risk calculation). The doses range between 8.8 and 394 μSv yr(-1), always lower than the effective dose limit for the public, 1 mSv yr(-1). The highest dose corresponds to the mixing area.
Bajwa, Ali S.; Rammappa, Manju; Lee, Ling; Nanda, Rajesh
2015-01-01
Introduction: Distal radius fracture (DRF) is a common injury and various treatment modalities including open reduction and internal fixation (ORIF) with volar locking plate are available. More recently, a non-invasive external fixator has been used. Aims: To prospectively compare the use of a non-invasive external fixator with early dynamisation for DRF against ORIF with volar locking plate control group. Methods: Consecutive patients with closed DRF were included in a prospective case-controlled study. Patients were assigned to non-invasive external fixator or ORIF. Minimum follow-up was two years. Follow-up was at weeks 2, 4, 6, 8, 12, 26 and at one and two-year post-operatively. The outcome measures included demographic details, injury mechanism, AO fracture type, risk factors, body mass index (BMI), ulnar styloid fracture and dorsal comminution, radiographs, grip strength and DASH score. Results: Consecutive 50 patients were treated either with non-invasive external fixator (25/50) or with ORIF (25/50) and the mean age of the two groups was 53 years (SD 17.1) and 49 years (SD 19.5), respectively. Demographics were matched in two groups. In the non-invasive external fixator group, there were 10 AO Type-A, 5 Type-B and 10 Type-C fractures. The ORIF group included 8 Type-A, 6 Type-B and 11 Type-C fractures. The mean DASH score at three-months and one-year post-injury in non-invasive fixator group was 12.2 (SD 3.1) and 3.5 (SD 0.7), respectively, significantly greater than those of ORIF group 14.5 (SD 5.6) and 11.2 (SD 4.4), respectively (p < 0.05). Conclusion: DRF treated with non-invasive external fixator can give functional results superior to ORIF at three-months and the trend is maintained at one and two-year post-operatively. PMID:27163089
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
... that effect radiation exposures to plant workers and members of the public. Therefore, no changes or... socioeconomic resources. Therefore, no changes to or different types of non-radiological environmental impacts...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-10
... radiation exposures to plant workers and members of the public. Therefore, no radiological impacts are..., socioeconomic conditions, and minority- and low-income populations in the vicinity of SONGS 2 and 3 would also...
[Imaging of temporo-mandibular disorders].
Felizardo, Rufino; Foucart, Jean-Michel; Pizelle, Christophe
2012-03-01
Dominated for years by standard films (tomographic mouth open and mouth closed X-rays, MRI) radiographs of the TMJ have progressively lost their usefulness to diagnosticians who have progressively increased their reliance on well codified clinical examinations, which suffice in a great majority of cases.The indications for and diagnostic worth of radiological studies and the impact they have on the management of TMJ disorders are today quite low especially when the high cost of procedures like MRI, computerized tomography, and CBCT is taken into account. In this article we discuss the various maladies that dentists might encounter and the situations in which radiological examinations are still indicated. © EDP Sciences, SFODF, 2012.
Fitzmaurice, Gerard J; Brown, Robin; Cranley, Brian; Conlon, Enda F; Todd, R Alan J; O'Donnell, Mark E
2010-09-01
Radiological investigations have become a key adjunct in patient management and consequently radiation exposure to patients is increasing. The study objectives were to examine the use of radiological investigations in the management of acute surgical patients and to assess whether a guideline-based radiation exposure risk/benefit analysis can aid in the choice of radiological investigation used. A prospective observational study was completed over a 12-week period from April to July 2008 for all acute surgical admissions. Data recorded included demographics, clinical presentation, differential diagnosis, investigations, surgical interventions, and final clinical outcome. The use of radiological investigative modalities as an adjunct to clinical assessment was then evaluated against The Royal College of Radiologists (RCR) guidelines. A total of 380 acute surgical admissions (M = 174, F = 185, children = 21) were assessed during the study period. Seven hundred thirty-four radiological investigations were performed with a mean of 1.93 investigations per patient. Based on the RCR guidelines, 680 (92.6%) radiological investigations were warranted and included 142 CT scans (19.3%), 129 chest X-rays (17.6%), and 85 abdominal X-rays (11.6%). Clinically, radiological imaging complemented surgical management in 326 patients (85.8%) and the management plan remained unchanged for the remaining 54 patients (14.2%). This accounted for an average radiation dose of 4.18 millisievert (mSv) per patient or 626 days of background radiation exposure. CT imaging was responsible for the majority of the radiation exposure, with a total of 1310 mSv (82.6%) of the total radiation exposure being attributed to CT imaging in 20.8% of acute admissions. Subgroup analysis demonstrated that 92.8% of the CT scans performed were appropriate. Radiation exposure was generally low for the majority of acute surgical admissions. However, it is recommended that CT imaging requests be evaluated carefully, particularly for patients with clinically confirmed pathologies and in younger women.
Kalhor, Rohollah; Amini, Saeed; Emami, Majid; Kakasoltani, Keivan; Rhamani, Nasim; Kalhor, Leila
2016-01-01
Introduction Efficient use of resources in organizations is one of the most important duties of managers. Appropriate allocation of resources can help managers to do this well. The aim of this study was to determine the cost of radiology services and to compare it with governmental tariffs (introduced by the Ministry of Health in Iran). Methods This was a descriptive and applied study that was conducted using the retrospective approach. First, activity centers were identified on the basis of five main groups of hospital activities. Then, resources and resource drivers, activities, and hospital activity drivers were identified. At the next step, the activities related to the delivery of radiology process were identified. Last, through allocation of activities cost to the cost objects, the cost price of 66 services that were delivered in the radiology department were calculated. The data were collected by making checklists, using the hospital’s information system, observations, and interviews. Finally, the data were analyzed using the non-parametric Wilcoxon test, Microsoft Excel, and SPSS software, version 18. Results The findings showed that from the total cost of wages, materials, and overhead obtained, the unit cost of the 66 cost objects (delivered services) in the Radiology Department were calculated using the ABC method (Price of each unit of Nephrostogram obtained $15.8 and Cystogram obtained $18.4). The Kolmogorov-Smirnov test indicated that the distribution of data of cost price using the ABC method was not normal (p = 0.000). The Wilcoxon test showed that there was a significant difference between the cost of services and the tariff of radiology services (p = 0.000). Conclusions The cost of delivered services in radiology departments was significantly higher than approved tariffs of the Ministry of Health, which can have a negative impact on the quality of services. PMID:27054013
Kalhor, Rohollah; Amini, Saeed; Emami, Majid; Kakasoltani, Keivan; Rhamani, Nasim; Kalhor, Leila
2016-02-01
Efficient use of resources in organizations is one of the most important duties of managers. Appropriate allocation of resources can help managers to do this well. The aim of this study was to determine the cost of radiology services and to compare it with governmental tariffs (introduced by the Ministry of Health in Iran). This was a descriptive and applied study that was conducted using the retrospective approach. First, activity centers were identified on the basis of five main groups of hospital activities. Then, resources and resource drivers, activities, and hospital activity drivers were identified. At the next step, the activities related to the delivery of radiology process were identified. Last, through allocation of activities cost to the cost objects, the cost price of 66 services that were delivered in the radiology department were calculated. The data were collected by making checklists, using the hospital's information system, observations, and interviews. Finally, the data were analyzed using the non-parametric Wilcoxon test, Microsoft Excel, and SPSS software, version 18. The findings showed that from the total cost of wages, materials, and overhead obtained, the unit cost of the 66 cost objects (delivered services) in the Radiology Department were calculated using the ABC method (Price of each unit of Nephrostogram obtained $15.8 and Cystogram obtained $18.4). The Kolmogorov-Smirnov test indicated that the distribution of data of cost price using the ABC method was not normal (p = 0.000). The Wilcoxon test showed that there was a significant difference between the cost of services and the tariff of radiology services (p = 0.000). The cost of delivered services in radiology departments was significantly higher than approved tariffs of the Ministry of Health, which can have a negative impact on the quality of services.
Rosenkrantz, Andrew B; Ginocchio, Luke A
2016-07-01
The aim of the present study was to assess the potential usefulness of written instructional vignettes relating to publication and journalism ethics in radiology via a survey of radiology trainees. A literature review was conducted to guide the development of vignettes, each describing a scenario relating to an ethical issue in research and publication, with subsequent commentary on the underlying ethical issue and potential approaches to its handling. Radiology trainees at a single institution were surveyed regarding the vignettes' perceived usefulness. A total of 21 vignettes were prepared, addressing institutional review board and human subjects protection, authorship issues, usage of previous work, manuscript review, and other miscellaneous topics. Of the solicited trainees, 24.7% (16/65) completed the survey. On average among the vignettes, 94.0% of the participants found the vignette helpful; 19.9 received prior formal instruction on the issue during medical training; 40.0% received prior informal guidance from a research mentor; and 42.0% indicated that the issue had arisen in their own or a peer's prior research experience. The most common previously experienced specific issue was authorship order (93.8%). Free-text responses were largely favorable regarding the value of the vignettes, although also indicated numerous challenges in properly handling the ethical issues: impact of hierarchy, pressure to publish, internal politics, reluctance to conduct sensitive conversations with colleagues, and variability in journal and professional society policies. Radiology trainees overall found the vignettes helpful, addressing commonly encountered topics for which formal and informal guidance were otherwise lacking. The vignettes are publicly available through the Association of University Radiologists (AUR) website and may foster greater insights by investigators into ethical aspects of the publication and journalism process, thus contributing to higher quality radiology research. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Volumetric CT-images improve testing of radiological image interpretation skills.
Ravesloot, Cécile J; van der Schaaf, Marieke F; van Schaik, Jan P J; ten Cate, Olle Th J; van der Gijp, Anouk; Mol, Christian P; Vincken, Koen L
2015-05-01
Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Two groups of medical students (n=139; n=143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students' test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p<.001). The volumetric CT-image testing program was considered user-friendly. This study shows that volumetric image questions can be successfully integrated in students' radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Influence of radiological emphysema on lung function test in idiopathic pulmonary fibrosis.
Bodlet, Aline; Maury, Gisèle; Jamart, Jacques; Dahlqvist, Caroline
2013-11-01
Idiopathic pulmonary fibrosis (IPF) is one of the most frequent interstitial lung disease. Emphysema can be associated with IPF as described in the «Combined pulmonary fibrosis and emphysema» syndrome. The primary endpoint of this retrospective cohort study was to evaluate the impact of the association of IPF and emphysema on lung function tests parameters (FVC, TLC, FEV1, FEV1/FVC and DLCO). The secondary endpoint was to assess the impact of the associated radiological emphysema on lung function parameters used in the du Bois prognostic score recently developed by Ron du Bois et al. We retrospectively reviewed the medical files of 98 patients with lung fibrosis who were followed in our University Hospital with access to pharmacological studies and lung transplantation from 1981 to 2011. Fifty six patients were considered for analysis. The collected data included gender, age, smoking history and respiratory hospitalizations. We also analysed their pulmonary functional parameters along with radiological characteristics, in particular the presence of emphysema which was assessed on thoracic high resolution CT scan. The du Bois score was retrospectively calculated from these data. TLC and FVC at diagnosis were significantly higher in the IPF-E group compared to the IPF group (respectively 86.6 ± 17.2% pv versus 72.0 ± 15.0% pv; p: 0.004 and 86.8 ± 18.4% pv versus 72.6 ± 20.6% pv; p: 0.020). The [Formula: see text] used in the calculation of the du Bois prognostic score was significantly higher in the IPF-E group. By cons, [Formula: see text] was not statistically different between the two groups. Radiological emphysema associated with IPF had an impact on pulmonary function tests. Despite this difference, the du Bois score was not statistically different between these two groups. Nevertheless, after one year of follow up, the patients with emphysema were in a subclass with a lower mortality rate than those without emphysema. Copyright © 2013 Elsevier Ltd. All rights reserved.
ESR concept paper on value-based radiology.
2017-10-01
The European Society of Radiology (ESR) established a Working Group on Value-Based Imaging (VBI WG) in August 2016 in response to developments in European healthcare systems in general, and the trend within radiology to move from volume- to value-based practice in particular. The value-based healthcare (VBH) concept defines "value" as health outcomes achieved for patients relative to the costs of achieving them. Within this framework, value measurements start at the beginning of therapy; the whole diagnostic process is disregarded, and is considered only if it is the cause of errors or complications. Making the case for a new, multidisciplinary organisation of healthcare delivery centred on the patient, this paper establishes the diagnosis of disease as a first outcome in the interrelated activities of the healthcare chain. Metrics are proposed for measuring the quality of radiologists' diagnoses and the various ways in which radiologists provide value to patients, other medical specialists and healthcare systems at large. The ESR strongly believes value-based radiology (VBR) is a necessary complement to existing VBH concepts. The Society is determined to establish a holistic VBR programme to help European radiologists deal with changes in the evolution from volume- to value-based evaluation of radiological activities. Main Messages • Value-based healthcare defines value as patient's outcome over costs. • The VBH framework disregards the diagnosis as an outcome. • VBH considers diagnosis only if wrong or a cause of complications. • A correct diagnosis is the first outcome that matters to patients. • Metrics to measure radiologists' impacts on patient outcomes are key. • The value provided by radiology is multifaceted, going beyond exam volumes.
Trainees May Add Value to Patient Care by Decreasing Addendum Utilization in Radiology Reports.
Balthazar, Patricia; Konstantopoulos, Christina; Wick, Carson A; DeSimone, Ariadne K; Tridandapani, Srini; Simoneaux, Stephen; Applegate, Kimberly E
2017-11-01
The purpose of this study was to evaluate the impact of trainee involvement and other factors on addendum rates in radiology reports. This retrospective study was performed in a tertiary care pediatric hospital. From the institutional radiology data repository, we extracted all radiology reports from January 1 to June 30, 2016, as well as trainee (resident or fellow) involvement, imaging modality, patient setting (emergency, inpatient, or outpatient), order status (routine vs immediate), time of interpretation (regular work hours vs off-hours), radiologist's years of experience, and sex. We grouped imaging modalities as advanced (CT, MRI, and PET) or nonadvanced (any modality that was not CT, MRI, or PET) and radiologist experience level as ≤ 20 years or > 20 years. Our outcome measure was the rate of addenda in radiology reports. Statistical analysis was performed using multivariate logistic regression. From 129,033 reports finalized during the study period, 418 (0.3%) had addenda. Reports generated without trainees were 12 times more likely than reports with trainee involvement to have addenda (odds ratio [OR] = 12.2, p < 0.001). Advanced imaging studies were more likely than nonadvanced studies to be associated with addendum use (OR = 4.7, p < 0.001). Reports generated for patients in emergency or outpatient settings had a slightly higher likelihood of addendum use than those in an inpatient setting (OR = 1.5, p = 0.04; and OR = 1.3, p = 0.04, respectively). Routine orders had a slightly higher likelihood of addendum use compared with immediate orders (OR = 1.3, p = 0.01). We found no difference in addendum use by radiologist's sex, radiologist's years of experience, emergency versus outpatient setting, or time of interpretation. Trainees may add value to patient care by decreasing addendum rates in radiology reports.
Using Social Media to Share Your Radiology Research: How Effective Is a Blog Post?
Hoang, Jenny K; McCall, Jonathan; Dixon, Andrew F; Fitzgerald, Ryan T; Gaillard, Frank
2015-07-01
The aim of this study was to compare the volume of individuals who viewed online versions of research articles in 2 peer-reviewed radiology journals and a radiology blog promoted by social media. The authors performed a retrospective study comparing online analytic logs of research articles in the American Journal of Neuroradiology (AJNR) and the American Journal of Roentgenology (AJR) and a blog posting on Radiopaedia.org from April 2013 to September 2014. All 3 articles addressed the topic of reporting incidental thyroid nodules detected on CT and MRI. The total page views for the research articles and the blog article were compared, and trends in page views were observed. Factors potentially affecting trends were an AJNR podcast and promotion of the blog article on the social media platforms Facebook, Tumblr, and Twitter to followers of Radiopaedia.org in February 2014 and August 2014. The total numbers of page views during the study period were 2,421 for the AJNR article and 3,064 for the AJR article. The Radiopaedia.org blog received 32,675 page views, which was 13.6 and 10.7 times greater than AJNR and AJR page views, respectively, and 6.0 times greater than both journal articles combined. Months with activity above average for the blog and the AJNR article coincided with promotion by Radiopaedia.org on social media. Dissemination of scientific material on a radiology blog promoted on social media can substantially augment the reach of more traditional publication venues. Although peer-reviewed publication remains the most widely accepted measure of academic productivity, researchers in radiology should not ignore opportunities for increasing the impact of research findings via social media. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Radiology resident teaching skills improvement: impact of a resident teacher training program.
Donovan, Andrea
2011-04-01
Teaching is considered an essential competency for residents to achieve during their training. Instruction in teaching skills may assist radiology residents in becoming more effective teachers and increase their overall satisfaction with teaching. The purposes of this study were to survey radiology residents' teaching experiences during residency and to assess perceived benefits following participation in a teaching skills development course. Study participants were radiology residents with membership in the American Alliance of Academic Chief Residents in Radiology or the Siemens AUR Radiology Resident Academic Development Program who participated in a 1.5-hour workshop on teaching skills development at the 2010 Association of University Radiologists meeting. Participants completed a self-administered, precourse questionnaire that addressed their current teaching strategies, as well as the prevalence and structure of teaching skills training opportunities at their institutions. A second postcourse questionnaire enabled residents to evaluate the seminar and assessed new knowledge and skill acquisition. Seventy-eight residents completed the precourse and postcourse questionnaires. The vast majority of respondents indicated that they taught medical students (72 of 78 [92.3%]). Approximately 20% of residency programs (17 of 78) provided residents with formal didactic programs on teaching skills. Fewer than half (46.8%) of the resident respondents indicated that they received feedback on their teaching from attending physicians (36 of 77), and only 18% (13 of 78) routinely gave feedback to their own learners. All of the course participants agreed or strongly agreed that this workshop was helpful to them as teachers. Few residency programs had instituted resident teacher training curricula. A resident teacher training workshop was perceived as beneficial by the residents, and they reported improvement in their teaching skills. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
New Zealand Dairy Farming: Milking Our Environment for All Its Worth
NASA Astrophysics Data System (ADS)
Foote, Kyleisha J.; Joy, Michael K.; Death, Russell G.
2015-09-01
Over the past two decades there have been major increases in dairy production in New Zealand. This increase in intensity has required increased use of external inputs, in particular fertilizer, feed, and water. Intensified dairy farming thus incurs considerable environmental externalities: impacts that are not paid for directly by the dairy farmer. These externalities are left for the wider New Zealand populace to deal with, both economically and environmentally. This is counter-intuitive given the dairy industry itself relies on a `clean green' image to maximize returns. This is the first nationwide assessment of some of the environmental costs of the recent increase of dairy intensification in New Zealand. Significant costs arise from nitrate contamination of drinking water, nutrient pollution to lakes, soil compaction, and greenhouse gas emissions. At the higher end, the estimated cost of some environmental externalities surpasses the 2012 dairy export revenue of NZ11.6 billion and almost reaches the combined export revenue and dairy's contribution to Gross Domestic Product in 2010 of NZ5 billion. For the dairy industry to accurately report on its profitability and maintain its sustainable marketing label, these external costs should be reported. This assessment is in fact extremely conservative as many impacts have not been valued, thus, the total negative external impact of intensified dairying is probably grossly underestimated.
Green Net Value Added as a Sustainability Metric Based on ...
Sustainability measurement in economics involves evaluation of environmental and economic impact in an integrated manner. In this study, system level economic data are combined with environmental impact from a life cycle assessment (LCA) of a common product. We are exploring a costing approach that captures traditional costs but also incorporates externality costs to provide a convenient, easily interpretable metric. Green Net Value Added (GNVA) is a type of full cost accounting that incorporates total revenue, the cost of materials and services, depreciation, and environmental externalities. Two, but not all, of the potential environmental impacts calculated by the standard LCIA method (TRACI) could be converted to externality cost values. We compute externality costs disaggregated by upstream sectors, full cost, and GNVA to evaluate the relative sustainability of Bounty® paper towels manufactured at two production facilities. We found that the longer running, more established line had a higher GNVA than the newer line. The dominant factors contributing to externality costs are calculated to come from the stationary sources in the supply chain: electricity generation (27-35%), refineries (20-21%), pulp and paper making (15-23%). Health related externalities from Particulate Matter (PM2.5) and Carbon Dioxide equivalent (CO2e) emissions appear largely driven by electricity usage and emissions by the facilities, followed by pulp processing and transport. Supply
New Zealand Dairy Farming: Milking Our Environment for All Its Worth.
Foote, Kyleisha J; Joy, Michael K; Death, Russell G
2015-09-01
Over the past two decades there have been major increases in dairy production in New Zealand. This increase in intensity has required increased use of external inputs, in particular fertilizer, feed, and water. Intensified dairy farming thus incurs considerable environmental externalities: impacts that are not paid for directly by the dairy farmer. These externalities are left for the wider New Zealand populace to deal with, both economically and environmentally. This is counter-intuitive given the dairy industry itself relies on a 'clean green' image to maximize returns. This is the first nationwide assessment of some of the environmental costs of the recent increase of dairy intensification in New Zealand. Significant costs arise from nitrate contamination of drinking water, nutrient pollution to lakes, soil compaction, and greenhouse gas emissions. At the higher end, the estimated cost of some environmental externalities surpasses the 2012 dairy export revenue of NZ$11.6 billion and almost reaches the combined export revenue and dairy's contribution to Gross Domestic Product in 2010 of NZ$5 billion. For the dairy industry to accurately report on its profitability and maintain its sustainable marketing label, these external costs should be reported. This assessment is in fact extremely conservative as many impacts have not been valued, thus, the total negative external impact of intensified dairying is probably grossly underestimated.
A Poor Man's Nuclear Deterrent: Assessing the Value of Radiological Weapons for State Actors
NASA Astrophysics Data System (ADS)
Donohue, Nathan
The threat of weapons of mass destruction is an issue which remains at the forefront on national security. Nuclear, chemical, and biological weapons are all considered very dangerous by both state and non-state actors. Radiological weapons exist in that same category yet are not held in the same regard; the reason that is given is that these types of weapons are not the weapons of mass destruction that the other three are. Instead, radiological weapons are better considered weapons of mass disruption. Accordingly, in the academic and policy literature there has been very little perceived value associated with such weapons for use by state actors. However the historical focus on the military efficacy of radiological weapons has obscured the obvious truth that they may pose significant value for state actors. What this research shows is that the explosion of a radiological weapon could disrupt a target area in ways which could cripple the economy of an adversary state and promote widespread fear concerning exposure to radiation. Any such attack would not only necessitate large scale evacuation, but cleanup, decontamination, demolition, territory exclusion, and relocation. Moreover, the effects of such an attack would be unlikely to remain an isolated event as evacuated and displaced citizens spread across the nation carrying both fear and residual radiation. All of these factors would only be compounded by a state actor's ability to not only develop such weapons, but to manufacture them in such a composition that contemporary examples of such weapons grossly underestimate their impact. Accordingly, radiological weapons could hold great value for any state actor wishing to pursue their development and to threaten their use. Moreover, "while RDDs may not be well suited as "military weapons" in the classic sense, the use of RDDs could be powerfully coercive."1 In that sense, state actors could even acquire radiological weapons for their deterrent value. 1James L. Ford, "Radiological Dispersal Devices: Assessing the Transnational Threat," Strategic Forum, No. 136, (March 1998), March 29, 2012, http://www.au.af.mil/au/awc/awcgate/ndu/forum136.htm.
Global health imaging curriculum in radiology residency programs: the fundamentals.
Wood, Mary F; Lungren, M P; Cinelli, C M; Johnson, B; Prater, A; Sood, S; Gerber, R E
2014-10-01
Recent advances in imaging technology have created new opportunities for medical imaging to improve health care in resource-restricted countries around the world. Radiology residents are increasingly interested in global health and imaging outreach, yet infrastructure and opportunities for international outreach are limited. With the recent change in the ABR exam schedule, residents now have more flexibility in the fourth year of training to pursue elective interests, including participation in global health projects. Creating a formalized global health imaging curriculum will improve the quality, quantity, and overall impact of initiatives undertaken by residents and their training programs. A curriculum is proposed that provides content, opportunities for global health project development, and established metrics for effective evaluation and assessment. Four components considered integral to a global health imaging curriculum are described: (1) global and public health education; (2) targeted travel medicine education; (3) basic imaging proficiency; and (4) practice attitudes and accountability. Methods are presented of differentiating curricula to increase applicability across the spectrum of training programs that vary in available resources. A blueprint is presented for formalizing a global health curriculum or elective rotation within a program, as well as a resource for residents, radiologists, and organizations to make a meaningful impact on global health. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Computer hardware for radiologists: Part I
Indrajit, IK; Alam, A
2010-01-01
Computers are an integral part of modern radiology practice. They are used in different radiology modalities to acquire, process, and postprocess imaging data. They have had a dramatic influence on contemporary radiology practice. Their impact has extended further with the emergence of Digital Imaging and Communications in Medicine (DICOM), Picture Archiving and Communication System (PACS), Radiology information system (RIS) technology, and Teleradiology. A basic overview of computer hardware relevant to radiology practice is presented here. The key hardware components in a computer are the motherboard, central processor unit (CPU), the chipset, the random access memory (RAM), the memory modules, bus, storage drives, and ports. The personnel computer (PC) has a rectangular case that contains important components called hardware, many of which are integrated circuits (ICs). The fiberglass motherboard is the main printed circuit board and has a variety of important hardware mounted on it, which are connected by electrical pathways called “buses”. The CPU is the largest IC on the motherboard and contains millions of transistors. Its principal function is to execute “programs”. A Pentium® 4 CPU has transistors that execute a billion instructions per second. The chipset is completely different from the CPU in design and function; it controls data and interaction of buses between the motherboard and the CPU. Memory (RAM) is fundamentally semiconductor chips storing data and instructions for access by a CPU. RAM is classified by storage capacity, access speed, data rate, and configuration. PMID:21042437
Coordinating patient care within radiology and across the enterprise.
McEnery, Kevin W
2014-12-01
For the practice of radiology, the transition to filmless imaging operations has resulted in a fundamental transition to more efficient clinical operations. In addition, the electronic delivery of diagnostic studies to the bedside has had a great impact on the care process throughout the health care enterprise. The radiology information system (RIS) has been at the core of the transition to filmless patient care. In a similar manner, the electronic medical record (EMR) is fundamentally and rapidly transforming the clinical enterprise into paperless/digital coordination of care. The widespread availability of EMR systems can be predicted to continue to increase the level of coordination of clinical care within the EMR framework. For the radiologist, readily available clinical information at the point of interpretation will continue to drive the evolution of the interpretation process, leading to improved patient outcomes. Regardless of practice size, efficient workflow processes are required to best leverage the functionality of IT systems. The radiologist should be aware of the scope of the RIS capabilities that allow for maximizing clinical benefit, and of the EMR system capabilities for improving = clinical imaging practice and care coordination across the enterprise. Radiology departments should be actively involved in forming practice patterns that allow efficient EMR-based clinical practice. This summary article is intended to assist radiologists in becoming active participants in the evolving role of both the RIS and EMR systems in coordinating efficient and effective delivery across the clinical enterprise. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Boşnak, Vuslat Keçik; Karaoğlan, İlkay; Sahin, Handan Haydaroğlu; Namiduru, Mustafa; Pehlivan, Mustafa; Okan, Vahap; Mete, Ayşe Özlem
2016-04-28
In this study, clinical, laboratory, radiological, and serological examinations of fascioliasis patients were analyzed, and data with a significant impact on differential diagnosis were evaluated. Clinical, radiological, and laboratory findings and treatment responses of a total of 22 fascioliasis patients, treated between October 2009 and September 2014, were evaluated. Nineteen patients were diagnosed with fascioliasis at the invasive phase and three patients at the chronic phase. Patients were followed up for clinical, laboratory, and radiology findings for a period of three months to one year after treatment. The most frequent complaints in both groups were abdominal pain, and the most common physical examination finding was epigastric tenderness. In the performed examination, an eosinophil elevation in whole blood count was detected in 19 patients (100%) in the hepatic phase, and in 2 patients (66.6%) in the biliary phase. The results of the Fasciola hepatica indirect hemagglutination assay (IHA) test ordered in the diagnosis were positive in all patients. Treatment with 10 mg/kg/day triclabendazole for two consecutive days was effective. Live parasites were extracted from patients in the biliary phase with endoscopic retrograde cholangiopancreatography. In the follow-ups, remission in IHA titer and clinical and radiological improvement was achieved in all patients. If hypereosinophilia is detected by peripheral smear in patients who are admitted with complaints such as abdominal pain, weakness, nausea, myalgia, and weight loss, radiological evaluation and serological tests should be performed and fascioliasis should be considered in the differential diagnosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whitehead, Donnie Wayne; Varnado, G. Bruce
2008-09-01
U.S. Nuclear Regulatory Commission nuclear power plant licensees and new reactor applicants are required to provide protection of their plants against radiological sabotage, including the placement of vital equipment in vital areas. This document describes a systematic process for the identification of the minimum set of areas that must be designated as vital areas in order to ensure that all radiological sabotage scenarios are prevented. Vital area identification involves the use of logic models to systematically identify all of the malicious acts or combinations of malicious acts that could lead to radiological sabotage. The models available in the plant probabilisticmore » risk assessment and other safety analyses provide a great deal of the information and basic model structure needed for the sabotage logic model. Once the sabotage logic model is developed, the events (or malicious acts) in the model are replaced with the areas in which the events can be accomplished. This sabotage area logic model is then analyzed to identify the target sets (combinations of areas the adversary must visit to cause radiological sabotage) and the candidate vital area sets (combinations of areas that must be protected against adversary access to prevent radiological sabotage). Any one of the candidate vital area sets can be selected for protection. Appropriate selection criteria will allow the licensee or new reactor applicant to minimize the impacts of vital area protection measures on plant safety, cost, operations, or other factors of concern.« less
Asaduzzaman, Khandoker; Mannan, Farhana; Khandaker, Mayeen Uddin; Farook, Mohideen Salihu; Elkezza, Aeman; Amin, Yusoff Bin Mohd; Sharma, Sailesh; Abu Kassim, Hasan Bin
2015-01-01
The concentrations of primordial radionuclides (226Ra, 232Th and 40K) in commonly used building materials (brick, cement and sand), the raw materials of cement and the by-products of coal-fired power plants (fly ash) collected from various manufacturers and suppliers in Bangladesh were determined via gamma-ray spectrometry using an HPGe detector. The results showed that the mean concentrations of 226Ra, 232Th and 40K in all studied samples slightly exceeded the typical world average values of 50 Bq kg(-1), 50 Bq kg(-1) and 500 Bq kg(-1), respectively. The activity concentrations (especially 226Ra) of fly-ash-containing cement in this study were found to be higher than those of fly-ash-free cement. To evaluate the potential radiological risk to individuals associated with these building materials, various radiological hazard indicators were calculated. The radium equivalent activity values for all samples were found to be lower than the recommended limit for building materials of 370 Bq kg(-1), with the exception of the fly ash. For most samples, the values of the alpha index and the radiological hazard (external and internal) indices were found to be within the safe limit of 1. The mean indoor absorbed dose rate was observed to be higher than the population-weighted world average of 84 nGy h(-1), and the corresponding annual effective dose for most samples fell below the recommended upper dose limit of 1 mSv y(-1). For all investigated materials, the values of the gamma index were found to be greater than 0.5 but less than 1, indicating that the gamma dose contribution from the studied building materials exceeds the exemption dose criterion of 0.3 mSv y(-1) but complies with the upper dose principle of 1 mSv y(-1).
Asaduzzaman, Khandoker; Mannan, Farhana; Khandaker, Mayeen Uddin; Farook, Mohideen Salihu; Elkezza, Aeman; Amin, Yusoff Bin Mohd; Sharma, Sailesh; Abu Kassim, Hasan Bin
2015-01-01
The concentrations of primordial radionuclides (226Ra, 232Th and 40K) in commonly used building materials (brick, cement and sand), the raw materials of cement and the by-products of coal-fired power plants (fly ash) collected from various manufacturers and suppliers in Bangladesh were determined via gamma-ray spectrometry using an HPGe detector. The results showed that the mean concentrations of 226Ra, 232Th and 40K in all studied samples slightly exceeded the typical world average values of 50 Bq kg−1, 50 Bq kg−1 and 500 Bq kg−1, respectively. The activity concentrations (especially 226Ra) of fly-ash-containing cement in this study were found to be higher than those of fly-ash-free cement. To evaluate the potential radiological risk to individuals associated with these building materials, various radiological hazard indicators were calculated. The radium equivalent activity values for all samples were found to be lower than the recommended limit for building materials of 370 Bq kg-1, with the exception of the fly ash. For most samples, the values of the alpha index and the radiological hazard (external and internal) indices were found to be within the safe limit of 1. The mean indoor absorbed dose rate was observed to be higher than the population-weighted world average of 84 nGy h–1, and the corresponding annual effective dose for most samples fell below the recommended upper dose limit of 1 mSv y–1. For all investigated materials, the values of the gamma index were found to be greater than 0.5 but less than 1, indicating that the gamma dose contribution from the studied building materials exceeds the exemption dose criterion of 0.3 mSv y-1 but complies with the upper dose principle of 1 mSv y−1. PMID:26473957
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kakinohana, Y; Toita, T; Heianna, J
Purpose: To provide an overview of reported incidents that occurred in a radiology department and to describe the most common causal source of incidents. Methods: Incident reports from the radiology department at the University of the Ryukyus Hospital between 2008 and 2013 were collected and analyzed retrospectively. The incident report form contains the following items, causal factors of the incident and desirable corrective actions to prevent recurrence of similar incidents. These items allow the institution to investigate/analyze root causes of the incidents and suggest measures to be taken to prevent further, similar incidents. The ‘causal factors of the incident’ itemmore » comprises multiple selections from among 24 selections and includes some synonymous selections. In this study, this item was re-categorized into four causal source types: (i) carelessness, (ii) lack of skill or knowledge, (iii) deficiencies in communication, and (iv) external factors. Results: There were a total of 7490 incident reports over the study period and 276 (3.7%) were identified as originating from the radiology department. The most frequent causal source type was carelessness (62%). The other three types showed similar frequencies (10–14%). The staff members involved in incidents indicate three predominant desirable corrective actions to prevent or decrease the recurrence of similar incidents. These are ‘improvement in communication’ (24%), ‘staff training/education’ (19%), and ‘daily medical procedures’ (22%), and the most frequent was ‘improvement in communication’. Even though the most frequent causal factor was related to carelessness, the most desirable corrective action indicated by the staff members was related to communication. Conclusion: Our finding suggests that the most immediate causes are strongly related to carelessness. However, the most likely underlying causes of incidents would be related to deficiencies in effective communication. At our department, therefore, the primary action to prevent/reduce similar incidents should be ‘communication improvement’.« less
Rubin, Geoffrey D; McNeil, Barbara J; Palkó, András; Thrall, James H; Krestin, Gabriel P; Muellner, Ada; Kressel, Herbert Y
2017-06-01
In both the United States and Europe, efforts to reduce soaring health care costs have led to intense scrutiny of both standard and innovative uses of imaging. Given that the United States spends a larger share of its gross domestic product on health care than any other nation and also has the most varied health care financing and delivery systems in the world, it has become an especially fertile environment for developing and testing approaches to controlling health care costs and value. This report focuses on recent reforms that have had a dampening effect on imaging use in the United States and provides a glimpse of obstacles that imaging practices may soon face or are already facing in other countries. On the basis of material presented at the 2015 meeting of the International Society for Strategic Studies in Radiology, this report outlines the effects of reforms aimed at (a) controlling imaging use, (b) controlling payer expense through changes in benefit design, and (c) controlling both costs and quality through "value-based" payment schemes. Reasons are considered for radiology practices on both sides of the Atlantic about why the emphasis needs to shift from providing a large volume of imaging services to increasing the value of imaging as manifested in clinical outcomes, patient satisfaction, and overall system savings. Options for facilitating the shift from volume to value are discussed, from the use of advanced management strategies that improve workflow to the creation of programs for patient engagement, the development of new clinical decision-making support tools, and the validation of clinically relevant imaging biomarkers. Radiologists in collaboration with industry must enhance their efforts to expand the performance of comparative effectiveness research to establish the value of these initiatives, while being mindful of the importance of minimizing conflicts of interest. © RSNA, 2017.
When Somebody's Watching: Researching the Workplace Impact of Academic Audit. AIR 2002 Forum Paper.
ERIC Educational Resources Information Center
Palermo, Josephine
The proposed quality assurance framework for higher education in Australia will, for the first time since the early 1990s, introduce a process of external quality monitoring through the auspices of the Australian Universities Quality Agency. There is little research that evaluates the impact of external monitoring on the experiences of staff,…
The Impact of External Quality Assessment on Universities: The Estonian Experience
ERIC Educational Resources Information Center
Vilgats, Birgit; Heidmets, Mati
2011-01-01
This article seeks to establish what impact external quality assessment had on universities in Estonia between 1997 and 2009. It is based on a study of the analysis of experts' reports of curricula accreditation and interviews with university and programme managers, undertaken between 2007 and 2009. The study included an analysis of 12 curricula…
Examining the Impact of External Influences on Police Use of Deadly Force over Time.
ERIC Educational Resources Information Center
White, Michael D.
2002-01-01
Used interrupted time-series analysis (ARIMA) to study the impact of legislation and judicial intervention on the use of deadly force by police officers in Philadelphia, Pennsylvania. Findings generally suggest that dynamic changes in the internal working environment can outweigh the influence of external mechanisms on deadly force use. Findings…
The Economic Impact of a Radiological Dispersal Device (RDE)
2009-03-01
construction sites” 9 (Boyle, 2002). In the Goiania case, the Cs-137 was acquired from an abandoned radiation- therapy unit when a private radiotherapy...Godiva Chocolatier 445292 Rocky Mountain Chocolate Factory 445292 Waggoner Chocolatier North American Industry Classification System (NAICS) Prior to
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faillace, E.R.; Cheng, J.J.; Yu, C.
A series of benchmarking runs were conducted so that results obtained with the RESRAD code could be compared against those obtained with six pathway analysis models used to determine the radiation dose to an individual living on a radiologically contaminated site. The RESRAD computer code was benchmarked against five other computer codes - GENII-S, GENII, DECOM, PRESTO-EPA-CPG, and PATHRAE-EPA - and the uncodified methodology presented in the NUREG/CR-5512 report. Estimated doses for the external gamma pathway; the dust inhalation pathway; and the soil, food, and water ingestion pathways were calculated for each methodology by matching, to the extent possible, inputmore » parameters such as occupancy, shielding, and consumption factors.« less
Tallón-López, J; Domínguez-Amador, J J; Andrés-García, J A
2014-01-01
Varus deformity of the proximal humerus in children is a little known pathology due to its low incidence of presentation. Progress has been made in recent years in understanding the possible etiology and pathophysiological causes. Radiological criteria for diagnosis and functional impairment that occurs have also been defined. However, there are few reports in the literature about the surgical treatment of this deformity in children. In this paper we present a case of surgical treatment of this deformity by corrective osteotomy fixed with precontoured external maleolar plate osteosynthesis. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.
Zanella, Gloria; Pullini, Serena; Como, Giuseppe; Bazzocchi, Massimo
2014-01-01
Purpose. To quantify the impact of diagnostic confidence on radiological diagnosis with a fuzzy logic-based method. Materials and Methods. Twenty-two oncologic patients with 20 cysts and 30 metastases ≤1 cm in size found at 64-row computed tomography were included. Two readers (R1/R2) expressed diagnoses as a subjective level of confidence P(d) in malignancy within the interval [0,1] rather than on a “crisp” basis (malignant/benign); confidence in benignancy was 1 − p(d). When cross-tabulating data according to the standard of reference, 2 × 2 table cells resulted from the aggregation between p(d)/1 − p(d) and final diagnosis. We then assessed (i) readers diagnostic performance on a fuzzy and crisp basis; (ii) the “divergence” δ(F, C) (%) as a measure of how confidence impacted on crisp diagnosis. Results. Diagnoses expressed with lower confidence increased fuzzy false positives compared to crisp ones (from 0 to 0.2 for R1; from 1 to 2.4 for R2). Crisp/fuzzy accuracy was 94.0%/93.6% (R1) and 94.0/91.6% (R2). δ(F, C) (%) was larger in the case of the less experienced reader (R2) (up to +7.95% for specificity). According to simulations, δ(F, C) (%) was negative/positive depending on the level of confidence in incorrect diagnoses. Conclusion. Fuzzy evaluation shows a measurable effect of uncertainty on radiological diagnoses. PMID:24587815
Outsourcing versus in-house maintenance of medical devices: a longitudinal, empirical study.
Miguel-Cruz, Antonio; Rios-Rincón, Adriana; Haugan, Gregory L
2014-03-01
To determine what factors have a significant influence on the performance of medical device maintenance outsourcing, and to determine how the performance of external governance structures differs depending on whether a hospital is private or public. This was a longitudinal study of 590 maintenance transactions at 20 hospitals in Bogotá, Colombia, involving 764 medical devices and 72 maintenance service providers. Maintenance performance data (i.e., turn-around time in hours; TAT) for the service providers (either in-house or outsourced) were primarily collected over a 20-month period, from December 2009-August 2011, by means of a monitoring procedure; then, a hazards model was run. The availability of specific repair parts, in-stock, in the city in which the medical devices were located, had a positive impact on the performance of both internal and external governance structures. Online service also had a positive impact on both, with a stronger positive impact on the performance of internal governance than on that of external governance. For transactions governed by external structures, better performance was seen in private hospitals than in public ones. In public health institutions, internal governance showed better performance than external governance. Both internal and external governance structures showed better performance in private healthcare institutions than in public ones. In public health institutions, internal governance shows better performance than external governance; this suggests that healthcare managers should reconsider the trend to eliminate in-house maintenance service staff in public healthcare institutions.
Funds Flow in the Era of Value-Based Health Care.
Itri, Jason N; Mithqal, Ayman; Krishnaraj, Arun
2017-06-01
Health care reform is creating significant challenges for hospital systems and academic medical centers (AMCs), requiring a new operating model to adapt to declining reimbursement, diminishing research funding, market consolidation, payers' focus on higher quality and lower cost, and greater cost sharing by patients. Maintaining and promoting the triple mission of clinical care, research, and education will require AMCs to be system-based with strong alignment around governance, operations, clinical care, and finances. Funds flow is the primary mechanism whereby an AMC maintains the triple mission through alignment of the hospital, physician practices, school of medicine, undergraduate university, and other professional schools. The purpose of this article is to discuss challenges with current funds flow models, impact of funds flow on academic and private practice radiology groups, and strategies that can increase funds flow to support radiology practices achieving clinical, research, and teaching missions in the era of value-based health care. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Mansoori, Bahar; Erhard, Karen K; Sunshine, Jeffrey L
2012-02-01
The availability of the Picture Archiving and Communication System (PACS) has revolutionized the practice of radiology in the past two decades and has shown to eventually increase productivity in radiology and medicine. PACS implementation and integration may bring along numerous unexpected issues, particularly in a large-scale enterprise. To achieve a successful PACS implementation, identifying the critical success and failure factors is essential. This article provides an overview of the process of implementing and integrating PACS in a comprehensive health system comprising an academic core hospital and numerous community hospitals. Important issues are addressed, touching all stages from planning to operation and training. The impact of an enterprise-wide radiology information system and PACS at the academic medical center (four specialty hospitals), in six additional community hospitals, and in all associated outpatient clinics as well as the implications on the productivity and efficiency of the entire enterprise are presented. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
Rana, Surinder Singh; Bhasin, Deepak Kumar; Nanda, Mohit; Siyad, Ismail; Gupta, Rajesh; Kang, Mandeep; Nagi, Birinder; Singh, Kartar
2010-06-01
External pancreatic fistulas (EPFs) are a therapeutic challenge. The present study was conducted to evaluate the efficacy of endoscopic transpapillary nasopancreatic drainage (NPD) in patients with EPF. Over 12 years, 23 patients (19 males) with EPF underwent attempted endoscopic transpapillary NPD. The end points were fistula closure with healing of pancreatic duct disruption on nasopancreatogram, or need for surgery. All 23 patients had persistent drain output (>50 mL/day) for >6 weeks. The mean output volume of the fistula was 223 mL (range: 60 mL to 750 mL). Sixteen patients had partial and seven patients had complete pancreatic duct disruption. The NPD could be successfully placed in 21/23 (91.3%) patients. Disruption was bridged in 15 of 16 patients with partial duct disruption. EPF healed in 2-8 weeks of placement of NPD in all of the patients with partial duct disruption that was bridged and there was no recurrence at a mean follow-up of 38 months. The EPF resolved in only 2/6 (33%) patients with complete duct disruption. External pancreatic fistulas developing following percutaneous drainage of pancreatic fluid collections or surgical necrosectomy can be effectively treated by transpapillary nasopancreatic drain placement especially when there is partial ductal disruption and the disruption can be bridged.
[Surgical treatment of pronation and supination external rotation trimalleolar fractures].
Xu, Ye-qing; Zhan, Bei-lei; He, Fei-xiong; Wei, Hong-da
2008-04-01
To explore the operative method and its clinical effects of pronation and supination external rotation trimalleolar fractures. From March 2000 to July 2006,42 patients of the pronation and supination external rotation trimalleolar fractures treated with open reduction and internal fixation. Thirty-one were males and 11 were females,with an average age of 40.5 years (from 19 to 76 years). Four cases were open fractures and 38 cases close fractures. The fractures were classified as pronation-external rotation (grade IV) injury in 18 cases and supination-external rotation (grade IV)in 24 cases according to the system of Lauge-Hansen. The time of injury to operation was 2 hours to 27 days. The medial, lateral and posterior malleolus were exposed by standard anteromedial and Gatellier-Chastang approaches. The reduction and internal fixation started with the posterior,then the medial and the lateral malleolus and distal tibiofibular syndesmosis in sequence. The anteroposterior, lateral and mostise X-ray films were taken after operation. All the patients were followed up for an average time of 13.5 months(from 6 to 24 months). The time of union was from 12 to 16 weeks. The results were excellent in 20,good in 16, fair in 4 and poor in 2 cases according to Baird-Jackson ankle scoring system based on pain, stability, walking ability,range of motion and radiological manifestations. The excellent and good rate was 85.7%. There were no infection,malunion and nonunion of the fractures except that the inserted screw to distal tibiofibular syndesmosis was broken in 1 case. The key of operative treatment is to restore the anatomy of ankle and to regain the ankle function maximally.
Development of a mini-mobile digital radiography system by using wireless smart devices.
Jeong, Chang-Won; Joo, Su-Chong; Ryu, Jong-Hyun; Lee, Jinseok; Kim, Kyong-Woo; Yoon, Kwon-Ha
2014-08-01
The current technologies that trend in digital radiology (DR) are toward systems using portable smart mobile as patient-centered care. We aimed to develop a mini-mobile DR system by using smart devices for wireless connection into medical information systems. We developed a mini-mobile DR system consisting of an X-ray source and a Complementary Metal-Oxide Semiconductor (CMOS) sensor based on a flat panel detector for small-field diagnostics in patients. It is used instead of the systems that are difficult to perform with a fixed traditional device. We also designed a method for embedded systems in the development of portable DR systems. The external interface used the fast and stable IEEE 802.11n wireless protocol, and we adapted the device for connections with Picture Archiving and Communication System (PACS) and smart devices. The smart device could display images on an external monitor other than the monitor in the DR system. The communication modules, main control board, and external interface supporting smart devices were implemented. Further, a smart viewer based on the external interface was developed to display image files on various smart devices. In addition, the advantage of operators is to reduce radiation dose when using remote smart devices. It is integrated with smart devices that can provide X-ray imaging services anywhere. With this technology, it can permit image observation on a smart device from a remote location by connecting to the external interface. We evaluated the response time of the mini-mobile DR system to compare to mobile PACS. The experimental results show that our system outperforms conventional mobile PACS in this regard.
Dynamic Ultrasonography of the Deep External Rotator Musculature of the Hip: A Descriptive Study.
Battaglia, Patrick J; Mattox, Ross; Haun, Daniel W; Welk, Aaron B; Kettner, Norman W
2016-07-01
No detailed reports exist describing the methodology of ultrasound image acquisition of the deep external rotator muscles of the hip. Because gluteal pain and sciatica are common, ultrasound may be a useful dynamic imaging adjunct in the evaluation of these patients. To describe dynamic ultrasonography of the deep external rotator muscles of the hip for diagnostic purposes. Descriptive. University radiology department. Participants (n = 25; 14 male) without gluteal pain or sciatica were enrolled (mean age 27.6 ± 4.7 years; mean body mass index 26.0 ± 4.1 kg/m(2)). Ultrasonographic cine clips oriented to the long axis of each deep external rotator muscle were captured. In addition, cine clips of the piriformis tendon and obturator internus tendon were obtained. Cine clips were analyzed approximately 1 week after completion of image acquisition independently by 2 blinded raters. A 5-point Likert scale to evaluate the diagnostic utility of the ultrasound image. The modal Likert scores for rater 1 were as follows: piriformis muscle = 4; piriformis tendon = 4; superior gemellus muscle = 3; obturator internus muscle = 4; obturator internus tendon = 4; inferior gemellus muscle = 4; quadratus femoris muscle = 4. The modal scores for rater 2 were: piriformis muscle = 4; piriformis tendon = 3; superior gemellus muscle = 4; obturator internus muscle = 3; obturator internus tendon = 4; inferior gemellus muscle = 3; quadratus femoris muscle = 4. Dynamic ultrasonography may be useful to image the hip deep external rotator musculature for diagnostic purposes and therefore aid in the evaluation of gluteal pain and sciatica. Future work should investigate the reliability and validity of ultrasonography in the evaluation of pathology of these muscles. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ng, Yook C.; Rodean, H.C.; Anspaugh, L.R.
The Nevada Applied Ecology Group (NAEG) Model of transport and dose for transuranic radionuclides was modified and expanded for the analysis of radionuclides other than pure alpha-emitters. Doses from internal and external exposures were estimated for the inventories and soil distributions of the individual radionuclides quantified in Areas 2 and 4 of the Nevada Test Site (NTS). We found that the dose equivalents via inhalation to liver, lungs, bone marrow, and bone surface from the plutonium isotopes and /sup 241/Am, those via ingestion to bone marrow and bone surfaces from /sup 90/Sr, and those via ingestion to all the targetmore » organs from /sup 137/Cs were the highest from internal exposures. The effective dose equivalents from /sup 137/Cs, /sup 152/Eu, and /sup 154/Eu were the highest from the external exposures. The /sup 60/Co, /sup 152/Eu, /sup 154/Eu, and /sup 155/Eu dose estimates for external exposures greatly exceeded those for internal exposures. The /sup 60/Co, /sup 90/Sr, and /sup 137/Cs dose equivalents from internal exposures were underestimated due to the adoption of some of the foodchain parameter values originally selected for /sup 239/Pu. Nonetheless, the ingestion pathway contributed significantly to the dose estimates for /sup 90/Sr and /sup 137/Cs, but contributed very much less than external exposures to the dose estimates for /sup 60/Co. Therefore, the use of more appropriate values would not alter the identification of important radionuclides, pathways, target organs, and exposure modes in this analysis. 19 refs., 13 figs., 12 tabs.« less
Veldhuijzen van Zanten, Sophie E M; Lane, Adam; Heymans, Martijn W; Baugh, Joshua; Chaney, Brooklyn; Hoffman, Lindsey M; Doughman, Renee; Jansen, Marc H A; Sanchez, Esther; Vandertop, William P; Kaspers, Gertjan J L; van Vuurden, Dannis G; Fouladi, Maryam; Jones, Blaise V; Leach, James
2017-08-01
We aimed to perform external validation of the recently developed survival prediction model for diffuse intrinsic pontine glioma (DIPG), and discuss its utility. The DIPG survival prediction model was developed in a cohort of patients from the Netherlands, United Kingdom and Germany, registered in the SIOPE DIPG Registry, and includes age <3 years, longer symptom duration and receipt of chemotherapy as favorable predictors, and presence of ring-enhancement on MRI as unfavorable predictor. Model performance was evaluated by analyzing the discrimination and calibration abilities. External validation was performed using an unselected cohort from the International DIPG Registry, including patients from United States, Canada, Australia and New Zealand. Basic comparison with the results of the original study was performed using descriptive statistics, and univariate- and multivariable regression analyses in the validation cohort. External validation was assessed following a variety of analyses described previously. Baseline patient characteristics and results from the regression analyses were largely comparable. Kaplan-Meier curves of the validation cohort reproduced separated groups of standard (n = 39), intermediate (n = 125), and high-risk (n = 78) patients. This discriminative ability was confirmed by similar values for the hazard ratios across these risk groups. The calibration curve in the validation cohort showed a symmetric underestimation of the predicted survival probabilities. In this external validation study, we demonstrate that the DIPG survival prediction model has acceptable cross-cohort calibration and is able to discriminate patients with short, average, and increased survival. We discuss how this clinico-radiological model may serve a useful role in current clinical practice.
Behaviour and fluxes of natural radionuclides in the production process of a phosphoric acid plant.
Bolívar, J P; Martín, J E; García-Tenorio, R; Pérez-Moreno, J P; Mas, J L
2009-02-01
In recent years there has been an increasing awareness of the occupational and public hazards of the radiological impact of non-nuclear industries which process materials containing naturally occurring radionuclides. These include the industries devoted to the production of phosphoric acid by treating sedimentary phosphate rocks enriched in radionuclides from the uranium series. With the aim of evaluating the radiological impact of a phosphoric acid factory located in the south-western Spain, the distribution and levels of radionuclides in the materials involved in its production process have been analysed. In this way, it is possible to asses the flows of radionuclides at each step and to locate those points where a possible radionuclide accumulation could be produced. A set of samples collected along the whole production process were analysed to determine their radionuclide content by both alpha-particle and gamma spectrometry techniques. The radionuclide fractionation steps and enrichment sources have been located, allowing the establishment of their mass (activity) balances per year.
Farr, Sebastian; Kranzl, Andreas; Hahne, Julia; Ganger, Rudolf
2017-08-01
Literature suggests that children and adolescents with idiopathic genua valga present with considerable gait deviations in frontal and transverse planes, including altered frontal knee moments, reduced external knee rotation, and increased external hip rotation. This study aimed to evaluate gait parameters in these patients after surgical correction using tension band plating (TBP). We prospectively evaluated 24 consecutive, skeletally immature patients, who received full-length standing radiographs and three-dimensional gait analysis before and after correction, and compared the results observed to a group of 11 typically developing peers. Prior to TBP the cohort showed significantly decreased (worse) internal frontal knee moments compared to the control group. After axis correction the mean and maximum knee moments changed significantly into normalized knee moments (p < 0.0001). In the transverse plane, only the foot progression angle (p = 0.020) changed significantly following intervention. Post-correction knee moments were similar to controls (p = 0.175), but the patient cohort exhibited a significantly decreased knee external rotation (p = 0.004) and increased external hip rotation (p < 0.001) during gait. In addition, the effect of transverse plane changes on knee moments in patients with restored, straight limb axis was calculated. Hence, patients with restored alignment but persistence of decreased external knee rotation demonstrated significantly greater knee moments than those without rotational abnormalities (p = 0.001). This study found that frontal knee moments during gait normalized in children with idiopathic genua valga after surgery. However, decreased external knee rotation and increased external hip rotation during gait persisted in the study cohort. Despite radiological correction, decreased external rotation during gait was associated with increases in medial knee loading. Surgical correction for children with genua valga but normal knee moments may be detrimental, due to redistribution of dynamic knee loading into the opposite joint compartment. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1617-1624, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Nitrosi, Andrea; Borasi, Giovanni; Nicoli, Franco; Modigliani, Gino; Botti, Andrea; Bertolini, Marco; Notari, Pietro
2007-06-01
Reggio Emilia hospital installed Picture Archiving and Communications Systems (PACS) as the final step towards a completely digital clinical environment completing the HIS/EMR and 1,400 web/terminals for patient information access. Financial benefits throughout the hospital were assessed upfront and measured periodically. Key indicators (radiology exam turnaround time, number of radiology procedures performed, inpatients length of stay before and after the PACS implementation, etc.) were analyzed and values were statistically tested to assess workflow and productivity improvements. The hospital went "filmless" in 28 weeks. Between the half of 2004 and the respective period in 2003, overall Radiology Department productivity increased by 12%, TAT improved by more than 60%. Timelier patient care resulted in decreased lengths of stay. Neurology alone experienced a 12% improvement in average patient stay. To quantify the impact of PACS on the average hospital stays and the expected productivity benefits to inpatient productivity were used a "high level" and a "detailed" business model. Annual financial upsides have exceeded $1.9 millions/year. A well-planned PACS deployment simplifies imaging workflow and improves patient care throughout the hospital while delivering substantial financial benefits. Staff buy-in was the key in this process and on-going training and process monitoring are a must.
Automated semantic indexing of figure captions to improve radiology image retrieval.
Kahn, Charles E; Rubin, Daniel L
2009-01-01
We explored automated concept-based indexing of unstructured figure captions to improve retrieval of images from radiology journals. The MetaMap Transfer program (MMTx) was used to map the text of 84,846 figure captions from 9,004 peer-reviewed, English-language articles to concepts in three controlled vocabularies from the UMLS Metathesaurus, version 2006AA. Sampling procedures were used to estimate the standard information-retrieval metrics of precision and recall, and to evaluate the degree to which concept-based retrieval improved image retrieval. Precision was estimated based on a sample of 250 concepts. Recall was estimated based on a sample of 40 concepts. The authors measured the impact of concept-based retrieval to improve upon keyword-based retrieval in a random sample of 10,000 search queries issued by users of a radiology image search engine. Estimated precision was 0.897 (95% confidence interval, 0.857-0.937). Estimated recall was 0.930 (95% confidence interval, 0.838-1.000). In 5,535 of 10,000 search queries (55%), concept-based retrieval found results not identified by simple keyword matching; in 2,086 searches (21%), more than 75% of the results were found by concept-based search alone. Concept-based indexing of radiology journal figure captions achieved very high precision and recall, and significantly improved image retrieval.
Design and Implementation of PACS at Georgetown University Hospital
NASA Astrophysics Data System (ADS)
Mun, S. K.; Benson, H.. R.; Choyke, P.; Fahey, F. H.; Wang, P. C.; Zeman, R. K...; Elliott, L. P.
1985-09-01
During the preparation and planning phase of the PACS project at Georgetown University Hospital it was realized that PACS requires truly the state of the art technology in data communication, image processing and man machine interfacing. It was also realized that un-like many other technology intensive devices used in radiology, PACS cannot be seen as an independent system that will provide well defined services. PACS will be the backbone of the department operation in clinical, educational and managerial functions. It will indeed be the nerve center of the radiologic services affecting every aspect of the department. PACS will have to be designed to perform in a cost-effective manner to widely varying needs within the radiology departments. The integration of ever changing complex technology that will impact every aspect of a radiology service is not a trivial matter. This transition period going from current manual film based PACS to Digital PACS can be long, expansive and disruptive unless careful planning preceeds the implementation. PACS is still an emerging technology at its infancy. Performance monitoring and evaluation of diversified functions have to be also established so that improvement to the system can be efficiently implemented. Thus the evaluation criteria should be also established as early as possible.
Lin, Y C; Dong, S L; Yeh, Y H; Wu, Y S; Lan, G Y; Liu, C M; Chu, T C
2005-07-01
The World Health Organization classified Taiwan as a serious epidemic-stricken area when the extent of severe acute respiratory syndrome (SARS) in Taiwan became clear. As of 11 July 2003, 671 probable SARS cases had been identified in Taiwan and 7 healthcare workers had died from the disease. Radiographers were easily infected by SARS because they had close contact with suspected or probable cases while conducting chest X-ray examinations. Three radiographers had been infected by the end of May 2003. Because of the impact of SARS on the Radiology Department, the department established a SARS emergency infection control team and re-designed the department's infection-control and emergency-management procedures based on the concept of risk-grade protection. This effort included installing a radiographic room at the fever-screening station, re-allocating human resources in the Radiology Department, training the department staff in infection control, and drafting new operational procedures for radiographers conducting X-ray examinations on SARS patients. The goal of this program was to reduce the infection rate and distribute materials efficiently in the department. This article introduces the emergency-management procedure of the Radiology Department during the SARS outbreak and the infection-protection experience of the department staff.
Patterns and Constraints of External Environment on Teaching.
ERIC Educational Resources Information Center
Lam, Y. L. J.
1989-01-01
External environments of 1,284 Canadian teachers from urban (n=600), suburban (n=234), and rural (n=450) schools were assessed using a version of the School Environment Constraint Instrument. External constraints confronting teachers ranged from moderate to low. The impact on classroom instruction must be considered to understand teachers'…
ERIC Educational Resources Information Center
Rodas, Naomi V.; Eisenhower, Abbey; Blacher, Jan
2017-01-01
Children with autism spectrum disorder (ASD) are at heightened risk for developing comorbid psychological disorders, including anxiety disorders, which may be further exacerbated by the presence of externalizing behaviors. Here, we examined how structural language and pragmatic language predicted anxiety and externalizing behaviors. Participants…
Isik, Umit; Damla, Nevzat; Akkoca, Dicle Bal; Cevik, Uğur
2012-06-01
This work deals with the mineralogical, geochemical and radiological characterisations of Selmo Formation in Batman neighbourhood. The upper Miocene-Pliocene Selmo Formation is common in the centre of Batman and composed of carbonated sandy claystones and silty-sandy stone lenses. The common whole minerals of the samples are quartz, feldspars, calcite and dolomite. The clay minerals are smectite, illite, chlorite and mixed-layer clay (chlorite-smectite). The geochemical mean values of the samples are 51.7% SiO(2); 12.6% Al(2)O(3); 6.2% Fe(2)O(3); 3.6% MgO; 6.3% CaO; 1.1% Na(2)O; 1.7% K(2)O; 0.8% TiO(2); 0.2% P(2)O(5); 0.1% MnO; and 0.03% Cr(2)O(3). In addition, baseline maps for the concentrations of each radionuclide, the radium equivalent activity and the outdoor gamma dose rate distributions have been plotted for the study area. The mean activity concentrations of (226)Ra, (232)Th, (40)K and (137)Cs were determined to be 32, 24, 210 and 9 Bq kg(-1), respectively. The assessments of the radiological hazard indices, such as radium equivalent activity, absorbed dose rate in air, annual effective dose equivalent, excess lifetime cancer risk, external hazard index and internal hazard index, were calculated and compared with the internationally accepted reference values. This study shows that the concentrations of radioactivities in the measured samples were within the recommended safety limits and did not pose to be any significant source of radiation hazard.
Gluck, Michael; Ross, Andrew; Irani, Shayan; Lin, Otto; Hauptmann, Ellen; Siegal, Justin; Fotoohi, Mehran; Crane, Robert; Robinson, David; Kozarek, Richard A
2010-12-01
Walled-off pancreatic necrosis (WOPN), a complication of severe acute pancreatitis (SAP), can become infected, obstruct adjacent structures, and result in clinical deterioration of patients. Patients with WOPN have prolonged hospitalizations, needing multiple radiologic and medical interventions. We compared an established treatment of WOPN, standard percutaneous drainage (SPD), with combined modality therapy (CMT), in which endoscopic transenteric stents were added to a regimen of percutaneous drains. Symptomatic patients with WOPN between January 2006 and August 2009 were treated with SPD (n = 43, 28 male) or CMT (n = 23, 17 male) and compared by disease severity, length of hospitalization, duration of drainage, complications, and number of radiologic and endoscopic procedures. Patient age (59 vs 54 years), sex (77% vs 58% male), computed tomography severity index (8.0 vs 7.2), number of endoscopic retrograde cholangiopancreatographies (2.0 vs 2.6), and percentage with disconnected pancreatic ducts (50% vs 46%) were equivalent in the CMT and SPD arms, respectively. Patients undergoing CMT had significantly decreased length of hospitalization (26 vs 55 days, P < .0026), duration of external drainage (83.9 vs 189 days, P < .002), number of computed tomography scans (8.95 vs 14.3, P < .002), and drain studies (6.5 vs 13, P < .0001). Patients in the SPD arm had more complications. For patients with symptomatic WOPN, CMT provided a more effective and safer management technique, resulting in shorter hospitalizations and fewer radiologic procedures than SPD. Copyright © 2010 AGA Institute. Published by Elsevier Inc. All rights reserved.
Soil radioactivity levels, radiological maps and risk assessment for the state of Kuwait.
Alazemi, N; Bajoga, A D; Bradley, D A; Regan, P H; Shams, H
2016-07-01
An evaluation of the radioactivity levels associated with naturally occurring radioactive materials has been undertaken as part of a systematic study to provide a surface radiological map of the State of Kuwait. Soil samples from across Kuwait were collected, measured and analysed in the current work. These evaluations provided soil activity concentration levels for primordial radionuclides, specifically members of the (238)U and (232)Th decay chains and (40)K which. The (238)U and (232)Th chain radionuclides and (40)K activity concentration values ranged between 5.9 ↔ 32.3, 3.5 ↔ 27.3, and 74 ↔ 698 Bq/kg respectively. The evaluated average specific activity concentrations of (238)U, (232)Th and (40)K across all of the soil samples have mean values of 18, 15 and 385 Bq/kg respectively, all falling below the worldwide mean values of 35, 40 and 400 Bq/kg respectively. The radiological risk factors are associated with a mean of 33.16 ± 2.46 nG/h and 68.5 ± 5.09 Bq/kg for the external dose rate and Radium equivalent respectively. The measured annual dose rates for all samples gives rise to a mean value of 40.8 ± 3.0 μSv/y while the internal and internal hazard indices have been found to be 0.23 ± 0.02 and 0.19 ± 0.01 respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.
MRI: unique costing and pricing issues.
Schwartz, H W; Jarl, D F
1985-01-01
Acquisition of magnetic resonance imaging (MRI) involves a plethora of costs not traditionally encountered in radiology procedure cost accounting models. Experiences with MRI gained at the University of Minnesota Hospitals and Clinics during 1984 uncovered a wide variety of unique costing issues which were eventually identified at the time when the MRI hospital charge was being established. Our experience at UMHC can provide those radiology departments now acquiring MRI with an earlier awareness of these special costing issues, hopefully resulting in better and more timely data collection. Current reimbursement and pricing issues are also having a dramatic impact on MRI costs at each institution and must be assessed in terms of third-party payor intentions.
Radiographer perceptions of managerial transformational leadership levels.
Legg, Jeffrey S; Akroyd, Duane; Jackowski, Melissa B
2010-01-01
Transformational leadership focuses on the ability of a leader to impact employees by inspiring employees to broaden interests in work as well as to be innovative and creative. It is positively associated with employee satisfaction and commitment to the organization. Characteristics of transformational leaders include confidence, ability to mange and deal with complexity, and belief in their employees and organizations. Considering the importance of leadership skills in radiology departments, this paper addresses directly the empirical evidence concerning radiographer's perception of their radiology managers and supervisors transformational leadership levels in the United States. Leadership can be taught, and we as a profession must begin to implement leadership training programs for our current and future leaders.
Arora, Rajesh; Chawla, Raman; Marwah, Rohit; Kumar, Vinod; Goel, Rajeev; Arora, Preeti; Jaiswal, Sarita; Sharma, Rakesh Kumar
2010-01-01
Nuclear and radiological emergencies (NREs) occurred globally and recent incidences in India are indicating toward the need for comprehensive medical preparedness required both at incident site and hospitals. The enhanced threat attributed toward insurgency is another causative factor of worry. The response capabilities and operational readiness of responders (both health and non-health service providers) in contaminated environment need to be supported by advancement in R & D and technological efforts to develop prophylactics and radiation mitigators. It is essential to develop phase 1 alternatives of such drugs for unseen threats as a part of initial preparedness. At the incident site and hospital level, external decontamination procedures need to be standardized and supported by protective clothing and Shudika kits developed by INMAS. The medical management of exposure requires systematic approach to perform triage, resuscitation and curative care. The internal contamination requires decorporation agents to be administered based on procedural diagnostics. Various key issues pertaining to policy decisions, R & D promotion, community awareness, specialized infrastructure for NREs preparedness has been discussed. The present review is an attempt to provide vital information about the current status of various radiation countermeasures and future perspective(s) ahead. PMID:21829316
Integrated research training program of excellence in radiochemistry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lapi, Suzanne
2015-09-18
The overall goal of this “Integrated Research Training Program of Excellence in Radiochemistry” is to provide a rich and deep research experience in state-of-the-art radiochemistry and in the fundamentals of radioisotopic labeling and tracer methodology to develop researchers who are capable of meeting the challenges of designing and preparing radiotracers of broad applicability for monitoring and imaging diverse biological systems and environmental processes. This program was based in the Departments of Radiology and Radiation Oncology at Washington University Medical School and the Department of Chemistry at the University of Illinois at Urbana Champaign, and it was initially directed by Professormore » Michael J. Welch as Principal Investigator. After his passing in 2012, the program was led by Professor Suzanne E. Lapi. Programmatic content and participant progress was overseen by an Internal Advisory Committee of senior investigators consisting of the PIs, Professor Mach from the Department of Radiology at Washington University and Professor John A. Katzenellenbogen of the Department of Chemistry at the University of Illinois. A small External Advisory Committee to give overall program guidance was also constituted of experts in radiolabeled compounds and in their applications in environmental and plant science.« less
Enhanced radioactivity due to natural oil and gas production and related radiological problems.
Kolb, W A; Wojcik, M
1985-10-01
Increased gamma radiation detected incidentally a few years ago in a North German oil field was traceable to radioactive scale. At the request of the Federal Ministry of the Interior a survey program was then established for dose rate measurements at various production sites, assessment of the radionuclide content of brines and scale and the Rn-222 content of natural gas. Dose equivalent rates of up to 50 mu Sv/h have been measured at the external surface of storage tanks for brines, but 73% of the 160 sites investigated did not show an increase above the natural background. Brines from gas fields contained Ra-226 of up to 286 Bq/l and scale of up to 1 kBq/g. In brines and scale from oil fields Ra-228 was usually the predominant radionuclide. Some samples contained "unsupported" Pb-210 and even Ac-227, too, but practically no uranium or thorium. The Rn-222 concentrations in natural gas samples varied between 0.004 and 4 Bq/l with a mean value of 0.6 Bq/l. It is shown that the radiation exposure due to natural gas consumption is negligible but some other problems or radiological relevance are recognized.
NASA Astrophysics Data System (ADS)
Caridi, F.; Marguccio, S.; Durante, G.; Trozzo, R.; Fullone, F.; Belvedere, A.; D'Agostino, M.; Belmusto, G.
2017-01-01
In this article natural radioactivity measurements and dosimetric evaluations in soil samples contaminated by Naturally Occurring Radioactive Materials (NORM) are made, in order to assess any possible radiological hazard for the population and for workers professionally exposed to ionizing radiations. Investigated samples came from the district of Crotone, Calabria region, South of Italy. The natural radioactivity investigation was performed by high-resolution gamma-ray spectrometry. From the measured gamma spectra, activity concentrations were determined for 226Ra , 234-mPa , 224Ra , 228Ac and 40K and compared with their clearance levels for NORM. The total effective dose was calculated for each sample as due to the committed effective dose for inhalation and to the effective dose from external irradiation. The sum of the total effective doses estimated for all investigated samples was compared to the action levels provided by the Italian legislation (D.Lgs.230/95 and subsequent modifications) for the population members (0.3mSv/y) and for professionally exposed workers (1mSv/y). It was found to be less than the limit of no radiological significance (10μSv/y).
NASA Astrophysics Data System (ADS)
Abdullah, Anisa; Hamzah, Zaini; Saat, Ahmad; Wood, Ab. Khalik
2016-01-01
Distribution of radionuclides from anthropogenic activities has been widely studied in marine coastal area. Due to rapid population growth and socio-economic development in Manjung area such as coal fired power plant, iron foundries, port development, waste discharged from factories and agriculture runoff may contribute to increase in pollution rate. The radioactive materials from anthropogenic activities could deteriorate the quality of the marine ecosystem and thus lead to possible radiological health risk to the population. Radionuclides (232Th, 238U and 40K) content in surface and profile sediment from Manjung coastal area was determined in this study. Radionuclides in sediment from seven locations were collected using sediment core sampling and measurements were carried out using Energy Dispersive X-ray Fluorescence (EDXRF) spectroscopy. The results show that the concentration of radionuclides in surface sediment and distribution trend of depth vertical profile sediment generally varies depending on locations. Enrichment factors (EF), geo-accumulation index (Igeo) and pollution index (PI) were applied to determine level of pollution of this study area. The radiological risks related to human exposure were evaluated based on external hazard index (Hex).
75 FR 20867 - DTE Energy; Enrico Fermi Atomic Power Plant, Unit 1
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-21
... Power Plant, Unit 1 Environmental Assessment and Finding of No Significant Impact for an Exemption From... County, Michigan. Environmental Assessment Identification of Proposed Action The proposed action is in... the Michigan Department of Natural Resources and the Environment, Radiological Protection and Medical...
Father involvement in child welfare: Associations with changes in externalizing behavior.
Leon, Scott C; Jhe Bai, Grace; Fuller, Anne K
2016-05-01
Nonresident fathers can have a significant impact on children's behavioral outcomes. Unfortunately, the impact of nonresident father involvement on the behavioral outcomes of children with child welfare involvement has received scant attention in the literature, a limitation the current study sought to address. A sample of 333 children in state custody in Illinois between the ages of six and 13 participated and were assessed using the externalizing behavior scale of the Child and Adolescent Needs and Strengths (CANS) at regular intervals throughout their time in care. Father involvement was measured through a review of case files and interviews with child welfare workers. Growth trajectories were fit to children's externalizing behavior across time and were predicted using Time 1 characteristics. Father involvement, total non-father relative involvement, and gender (girls) was associated with lower baseline externalizing behavior and the African American children in the sample experienced higher baseline externalizing behavior. However, only Time 1 father involvement predicted slope trajectories after controlling for Time 1 externalizing behavior; more father involvement was associated with lower externalizing behavior trajectories. These results suggest that even in the unique and stressful context of child welfare, father involvement can be protective regarding children's externalizing behaviors. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patrick Matthews
2011-08-01
CAU 104 comprises the 15 CASs listed below: (1) 07-23-03, Atmospheric Test Site T-7C; (2) 07-23-04, Atmospheric Test Site T7-1; (3) 07-23-05, Atmospheric Test Site; (4) 07-23-06, Atmospheric Test Site T7-5a; (5) 07-23-07, Atmospheric Test Site - Dog (T-S); (6) 07-23-08, Atmospheric Test Site - Baker (T-S); (7) 07-23-09, Atmospheric Test Site - Charlie (T-S); (8) 07-23-10, Atmospheric Test Site - Dixie; (9) 07-23-11, Atmospheric Test Site - Dixie; (10) 07-23-12, Atmospheric Test Site - Charlie (Bus); (11) 07-23-13, Atmospheric Test Site - Baker (Buster); (12) 07-23-14, Atmospheric Test Site - Ruth; (13) 07-23-15, Atmospheric Test Site T7-4; (14) 07-23-16,more » Atmospheric Test Site B7-b; (15) 07-23-17, Atmospheric Test Site - Climax These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives (CAAs). Additional information will be obtained by conducting a corrective action investigation before evaluating CAAs and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable CAAs that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on April 28, 2011, by representatives of the Nevada Division of Environmental Protection and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 104. The releases at CAU 104 consist of surface-deposited radionuclides from 30 atmospheric nuclear tests. The presence and nature of contamination at CAU 104 will be evaluated based on information collected from a field investigation. Radiological contamination will be evaluated based on a comparison of the total effective dose (TED) to the dose-based final action level (FAL). The presence of TED exceeding the FAL is considered a radiological contaminant of concern (COC). Anything identified as a COC will require corrective action. The TED will be calculated as the total of separate estimates of internal and external dose. Results from the analysis of soil samples will be used to calculate internal radiological dose. Thermoluminescent dosimeters will be used to measure external radiological dose. Based on process knowledge of the releases associated with the nuclear tests and radiological survey information about the location and shape of the resulting contamination plume, it was determined that the releases from the nuclear tests are co-located and will be investigated concurrently. A field investigation will be performed to define areas where TED exceeds the FAL and to determine whether other COCs are present at the site. The investigation will also collect information to determine the presence and nature of contamination associated with migration and excavation, as well as any potential releases discovered during the investigation. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to each CAS.« less
NASA Astrophysics Data System (ADS)
Brandt, Jørgen; Silver, Jeremy David; Heile Christensen, Jesper; Skou Andersen, Mikael; Geels, Camilla; Gross, Allan; Buus Hansen, Ayoe; Mantzius Hansen, Kaj; Brandt Hedegaard, Gitte; Ambelas Skjøth, Carsten
2010-05-01
Air pollution has significant negative impacts on human health and well-being, which entail substantial economic consequences. We have developed an integrated model system, EVA (External Valuation of Air pollution), to assess health-related economic externalities of air pollution resulting from specific emission sources/sectors. The EVA system was initially developed to assess externalities from power production, but in this study it is extended to evaluate costs at the national level. The EVA system integrates a regional-scale atmospheric chemistry transport model (DEHM), address-level population data, exposure-response functions and monetary values applicable for Danish/European conditions. Traditionally, systems that assess economic costs of health impacts from air pollution assume linear approximations in the source-receptor relationships. However, atmospheric chemistry is non-linear and therefore the uncertainty involved in the linear assumption can be large. The EVA system has been developed to take into account the non-linear processes by using a comprehensive, state-of-the-art chemical transport model when calculating how specific changes to emissions affect air pollution levels and the subsequent impacts on human health and cost. Furthermore, we present a new "tagging" method, developed to examine how specific emission sources influence air pollution levels without assuming linearity of the non-linear behaviour of atmospheric chemistry. This method is more precise than the traditional approach based on taking the difference between two concentration fields. Using the EVA system, we have estimated the total external costs from the main emission sectors in Denmark, representing the ten major SNAP codes. Finally, we assess the impacts and external costs of emissions from international ship traffic around Denmark, since there is a high volume of ship traffic in the region.
McKenzie, Suzanne H; Harris, Mark F
2013-11-01
The process of initiating and maintaining healthy lifestyle behaviours is complex, includes a number of distinct phases and is not static. Theoretical models of behaviour change consider psychological constructs such as intention and self efficacy but do not clearly consider the role of stress or psychological distress. General practice based interventions addressing lifestyle behaviours have been demonstrated to be feasible and effective however it is not clear whether general practitioners (GPs) take psychological health into consideration when discussing lifestyle behaviours. This qualitative study explores GPs' and patients' perspectives about the relationship between external stressors, psychological distress and maintaining healthy lifestyle behaviours. Semi-structured telephone interviews were conducted with 16 patients and 5 GPs. Transcripts from the interviews were thematically analysed and a conceptual model developed to explain the relationship between external stressors, psychological distress and healthly lifestyle behaviours. Participants were motivated to maintain a healthy lifestyle however they described a range of external factors that impacted on behaviour in both positive and negative ways, either directly or via their impact on psychological distress. The impact of external factors was moderated by coping strategies, beliefs, habits and social support. In some cases the process of changing or maintaining healthy behaviour also caused distress. The concept of a threshold level of distress was evident in the data with patients and GPs describing a certain level of distress required before it negatively influenced behaviour. Maintaining healthy lifestyle behaviours is complex and constantly under challenge from external stressors. Practitioners can assist patients with maintaining healthy behaviour by providing targeted support to moderate the impact of external stressors.
Epidemiology of Benign External Hydrocephalus in Norway-A Population-Based Study.
Wiig, Ulrikke S; Zahl, Sverre M; Egge, Arild; Helseth, Eirik; Wester, Knut
2017-08-01
Benign external hydrocephalus is defined as a rapidly increasing head circumference (occipitofrontal circumference) with characteristic radiological findings of increased subarachnoid cerebrospinal fluid spaces on neuroimaging. The incidence of benign external hydrocephalus has not been previously reported, and there is no available information on the ratio of benign external hydrocephalus in the population of hydrocephalic children. This study is retrospective and population-based study, geographically covering two health regions in the southern half of Norway with a total mean population of 3.34 million in the ten-year study period, constituting approximately 75% of the Norwegian population. Children with a head circumference crossing two percentiles, or greater than the 97.5th percentile, and with typical imaging findings of enlarged frontal subarachnoid spaces with or without enlarged ventricles were included. Children were excluded if they had a history of head trauma, intracranial hemorrhage, central nervous system infection, other known causes of hydrocephalus, or were born preterm defined as birth before 37 weeks of gestation. A total of 176 children fitting the criteria were identified, giving an incidence of 0.4 per 1000 live births. One hundred fifty-two (86.4%) of the patients were male, and mean age at referral was 7.3 months. Increasing head circumference was the main reason for referral in 158 (89.8%) patients and the only finding in 60 (34.1%) patients. Thirty-seven (21%) children had normal ventricles on imaging; the remainder had increased ventricular size. The incidence of pediatric hydrocephalus in Norway is reported to be 0.75 per 1000 live births, thus benign external hydrocephalus accounts for approximately 50% of hydrocephalic conditions in this population. The incidence of benign external hydrocephalus was found to be 0.4 per 1000 live births in this population. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Huang, Yang; Lowe, Henry J.; Hersh, William R.
2003-01-01
Objective: Despite the advantages of structured data entry, much of the patient record is still stored as unstructured or semistructured narrative text. The issue of representing clinical document content remains problematic. The authors' prior work using an automated UMLS document indexing system has been encouraging but has been affected by the generally low indexing precision of such systems. In an effort to improve precision, the authors have developed a context-sensitive document indexing model to calculate the optimal subset of UMLS source vocabularies used to index each document section. This pilot study was performed to evaluate the utility of this indexing approach on a set of clinical radiology reports. Design: A set of clinical radiology reports that had been indexed manually using UMLS concept descriptors was indexed automatically by the SAPHIRE indexing engine. Using the data generated by this process the authors developed a system that simulated indexing, at the document section level, of the same document set using many permutations of a subset of the UMLS constituent vocabularies. Measurements: The precision and recall scores generated by simulated indexing for each permutation of two or three UMLS constituent vocabularies were determined. Results: While there was considerable variation in precision and recall values across the different subtypes of radiology reports, the overall effect of this indexing strategy using the best combination of two or three UMLS constituent vocabularies was an improvement in precision without significant impact of recall. Conclusion: In this pilot study a contextual indexing strategy improved overall precision in a set of clinical radiology reports. PMID:12925544
Huang, Yang; Lowe, Henry J; Hersh, William R
2003-01-01
Despite the advantages of structured data entry, much of the patient record is still stored as unstructured or semistructured narrative text. The issue of representing clinical document content remains problematic. The authors' prior work using an automated UMLS document indexing system has been encouraging but has been affected by the generally low indexing precision of such systems. In an effort to improve precision, the authors have developed a context-sensitive document indexing model to calculate the optimal subset of UMLS source vocabularies used to index each document section. This pilot study was performed to evaluate the utility of this indexing approach on a set of clinical radiology reports. A set of clinical radiology reports that had been indexed manually using UMLS concept descriptors was indexed automatically by the SAPHIRE indexing engine. Using the data generated by this process the authors developed a system that simulated indexing, at the document section level, of the same document set using many permutations of a subset of the UMLS constituent vocabularies. The precision and recall scores generated by simulated indexing for each permutation of two or three UMLS constituent vocabularies were determined. While there was considerable variation in precision and recall values across the different subtypes of radiology reports, the overall effect of this indexing strategy using the best combination of two or three UMLS constituent vocabularies was an improvement in precision without significant impact of recall. In this pilot study a contextual indexing strategy improved overall precision in a set of clinical radiology reports.
PACS: implementation in the U.S. Department of Defense
NASA Astrophysics Data System (ADS)
Chacko, Anna K.; Wider, Ronald; Romlein, John R.; Cawthon, Michael A.; Richardson, Ronald R., Jr.; Lollar, H. William; Cook, Jay F.; Timboe, Harold L.; Johnson, Thomas G.; Fellows, Douglas W.
2000-05-01
The Department of Defense has been a leader in Radiology re- engineering for the past decade. Efforts have included the development of two landmark PACS specifications (MDIS and DIN- PACS), respective vendor selection and implementation programs. A Tri-Service (Army, Navy and Air Force) Radiology re-engineering program was initiated which identified transitioning to digital imaging, PACS and teleradiology as key enabling technologies in a changing business scenario. Subsequently, the systematic adjustment of procurement process for radiological imaging equipment included a focus on specifying PACS-capable-digital imaging modalities and mini- PACS as stepping stones to make the hospitals and health clinics PACS-ready. The success of the PACS and teleradiology program in the DOD is evidenced by the near filmless operation of most Army and Air Force Medical Centers, several community hospitals and several operational teleradiology constellations. Additionally, the MDIS PACSystem has become the commercial PACS product for General Electric Medical Systems. The DOD continues to forge ahead in the PACS arena by implementing advanced configurations and operational concepts such as the VRE (Virtual Radiology Environment), the negotiation of Regional Archiving and Regional PACS Maintenance Programs. Newer regulations (HIPAA, the FDA approval of digital mammography) have been promulgated impacting the culture and conduct of our business. Incorporating their requirements at the very outset will enable us to streamline the delivery of radiology. The DOD community has embraced the information age at multiple levels. The Healthcare portion of this community with these initiatives is integrating itself into DOD's future. The future holds great possibilities, promises and challenges for the DOD PACS programs.
Chocarro, Gloria; Amesty, María Virginia; Encinas, Jose Luis; Vilanova Sánchez, Alejandra; Hernandez, Francisco; Andres, Ane M; Gamez, Manolo; Tovar, Juan Antonio; Lopez Santamaria, Manuel
2016-02-01
Congenital portosystemic shunt (CPSS) is a rare entity without insufficiency in treatment issues. The aim of this article is to show our experience in the heterogeneity of this condition. A retrospective study of 25 CPSS in the period 1995 to 2014 was conducted. Description of the morphology, clinical impact, and treatment is given. According to the imaging techniques (IT), the shunt was apparently intrahepatic in 14 patients, extrahepatic in 10 patients, and mixed in 1 patient. In 14 children, IT showed hepatic portal circulation. In total shunts in which radiological examination was performed, invasive radiological techniques were able to demonstrate intrahepatic portal vein. In other patients, it was not investigated as they are asymptomatic. A child presented multiorgan failure with fulminant hepatic failure at birth. The shunt was radiologically closed and clinical impairment reversed rapidly. He is now asymptomatic with no longer images of CPSS in ultrasound scan controls. Also, seven children are asymptomatic at this time and are monitored periodically. Seven children had prenatal diagnosis, in five the shunt closed spontaneously. Nine children were symptomatic in their evolution (hyperammonemia, regenerative nodules, cholestasis, gastrointestinal bleeding). Of these, in five we performed balloon test occlusion, tolerated in all patients, followed by radiological closure. In our experience, the advancement of interventional radiology techniques avoided surgery to close the shunt. Morphologically, the CPSS is extremely heterogeneous, with multiple possible connections established. CPSS has multiple clinical presentations, from asymptomatic patients to acute liver failure. The therapeutic approach should be individualized and therefore held in overspecialized centers. Georg Thieme Verlag KG Stuttgart · New York.
Research Challenges and Opportunities for Clinically Oriented Academic Radiology Departments.
Decker, Summer J; Grajo, Joseph R; Hazelton, Todd R; Hoang, Kimberly N; McDonald, Jennifer S; Otero, Hansel J; Patel, Midhir J; Prober, Allen S; Retrouvey, Michele; Rosenkrantz, Andrew B; Roth, Christopher G; Ward, Robert J
2016-01-01
Between 2004 and 2012, US funding for the biomedical sciences decreased to historic lows. Health-related research was crippled by receiving only 1/20th of overall federal scientific funding. Despite the current funding climate, there is increased pressure on academic radiology programs to establish productive research programs. Whereas larger programs have resources that can be utilized at their institutions, small to medium-sized programs often struggle with lack of infrastructure and support. To address these concerns, the Association of University Radiologists' Radiology Research Alliance developed a task force to explore any untapped research productivity potential in these smaller radiology departments. We conducted an online survey of faculty at smaller clinically funded programs and found that while they were interested in doing research and felt it was important to the success of the field, barriers such as lack of resources and time were proving difficult to overcome. One potential solution proposed by this task force is a collaborative structured research model in which multiple participants from multiple institutions come together in well-defined roles that allow for an equitable distribution of research tasks and pooling of resources and expertise. Under this model, smaller programs will have an opportunity to share their unique perspective on how to address research topics and make a measureable impact on the field of radiology as a whole. Through a health services focus, projects are more likely to succeed in the context of limited funding and infrastructure while simultaneously providing value to the field. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Impact of Parenting Styles on Adolescent Externalizing and Substance Use: A Longitudinal Study.
ERIC Educational Resources Information Center
Stice, Eric; Barrera, Manuel, Jr.
Past research examining the influence of parenting styles on adolescent externalizing behaviors and substance use has left questions with regard to whether there is a relation between parental social support and adolescent externalizing symptomatology. This study examined the influence of parental control and social support on adolescent…
The Impact of External Resources on Conflict and Violence in Dating Relationships.
ERIC Educational Resources Information Center
Johnson, Katherine I.
Eighty-six college-aged, heterosexual couples completed questionnaires and subsequently were interviewed separately in order to test the hypothesis derived from social exchange theory that higher levels of conflict or violence will be reported in dating relationships in which one partner has fewer external resources. External resources were…
Parent Alcoholism Impacts the Severity and Timing of Children's Externalizing Symptoms
ERIC Educational Resources Information Center
Hussong, Andrea M.; Huang, Wenjing; Curran, Patrick J.; Chassin, Laurie; Zucker, Robert A.
2010-01-01
Although previous studies show that children of alcoholic parents have higher rates of externalizing symptoms compared to their peers, it remains unclear whether the timing of children's externalizing symptoms is linked to that of their parent's alcohol-related symptoms. Using a multilevel modeling approach, we tested whether children aged 2…
Teachers' Views of the Impact of School Evaluation and External Inspection Processes
ERIC Educational Resources Information Center
Hopkins, Elizabeth; Hendry, Helen; Garrod, Frank; McClare, Siobhan; Pettit, Daniel; Smith, Luke; Burrell, Hannah; Temple, Jennifer
2016-01-01
The research explores the views of teachers about how their teaching is evaluated by others. The tensions between evaluations motivated by the drive to improve practice (school self-evaluation) and evaluation related to external accountability (external evaluation-inspection) are considered, linked to findings and ideas reported in the literature.…
Optimal Software Strategies in the Presence of Network Externalities
ERIC Educational Resources Information Center
Liu, Yipeng
2009-01-01
Network externalities or alternatively termed network effects are pervasive in computer software markets. While software vendors consider pricing strategies, they must also take into account the impact of network externalities on their sales. My main interest in this research is to describe a firm's strategies and behaviors in the presence of…
The External Contingencies and Development Processes of Students with Emotional Disabilities
ERIC Educational Resources Information Center
Nikolaros, John
2015-01-01
This paper examines the external contingencies that students with emotional disabilities (ED) experience throughout childhood and adolescence. It presents an in-depth assessment of the impact of external dynamics on the emotional development of students with ED, and considers the school, home, and community support systems. The paper assesses…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hermann, Robert Michael, E-mail: hermann@strahlentherapie-westerstede.com; Abteilung Strahlentherapie und Spezielle Onkologie, Medizinische Hochschule Hannover; Meyer, Andreas
2013-12-01
Purpose: Radiation therapy is well established in the treatment of painful plantar fasciitis or heel spur. A retrospective analysis was conducted to investigate the effect of field definition on treatment outcome and to determine the impact of factors potentially involved. Methods and Materials: A review of treatment data of 250 patients (285 heels) with a mean follow-up time of 11 months showed that complete symptom remission occurred in 38%, partial remission in 32%, and no change in 19% (11% were lost to follow-up). Variables such as radiologic evidence of plantar spurs, their length, radiation dose, field size, age, sex, andmore » onset of pain before administration of radiation therapy were investigated in univariate and multivariate regression analyses. Results: Treatment response depended upon age >53 years, length of heel spur ≤6.5 mm (or no radiologic evidence of a heel spur), and onset of pain <12 months before radiation therapy. Patients with these clinical prerequisites stood a 93% chance of clinical response. Without these prerequisites, only 49% showed any impact. No influence of field size on treatment outcome became evident. Conclusion: Patients with short plantar heel spurs benefit from radiation therapy equally well as patients without any radiologic evidence. Moreover, smaller field sizes have the same positive effect as commonly used large field definitions covering the entire calcaneal bone. This leads to a recommendation of a considerable reduction of field size in future clinical practice.« less
EMP Attachment 3 DOE-SC PNNL Site Dose Assessment Guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.
2011-12-21
This Dose Assessment Guidance (DAG) describes methods to use to determine the Maximally-Exposed Individual (MEI) location and to estimate dose impact to that individual under the U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest National Laboratory (PNNL) Site Environmental Monitoring Plan (EMP). This guidance applies to public dose from radioactive material releases to the air from PNNL Site operations. This document is an attachment to the Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP) and describes dose assessment guidance for radiological air emissions. The impact of radiological air emissions from the U.S. Department of Energy Office ofmore » Science (DOE-SC) PNNL Site is indicated by dose estimates to a maximally exposed member of the public, referred to as the maximally exposed individual (MEI). Reporting requirements associated with dose to members of the public from radiological air emissions are in 40 CFR Part 61.94, WAC 246-247-080, and DOE Order 458.1. The DOE Order and state standards for dose from radioactive air emissions are consistent with U.S. Environmental Protection Agency (EPA) dose standards in 40 CFR 61.92 (i.e., 10 mrem/yr to a MEI). Despite the fact that the current Contract Requirements Document (CRD) for the DOE-SC PNNL Site operations does not include the requirement to meet DOE CRD 458.1, paragraph 2.b, public dose limits, the DOE dose limits would be met when EPA limits are met.« less
Rogers, M Brooke; Amlôt, Richard; Rubin, G James
2013-03-01
It is a common assumption that, in the event of a chemical, biological, radiological, or nuclear (CBRN) attack, a well-prepared and informed public is more likely to follow official recommendations regarding the appropriate safety measures to take. We present findings from a UK study investigating the ability of crisis communication to influence perceptions of risk and behavioral intentions in the general public in response to CBRN terrorism. We conducted a focus group study involving a scenario presented in mock news broadcasts to explore levels of public knowledge, information needs, and intended behavioral reactions to an attack involving an overt radiological dispersal device (RDD), or dirty bomb. We used the findings from these focus groups to design messages for the public that could be presented in a short leaflet. We then tested the effects of the leaflet on reactions to the same scenario in 8 further focus groups. The impact of the new messages on levels of knowledge, information needs, and intended compliance with official recommendations was assessed. The provision of information increased the perceived credibility of official messages and increased reported levels of intended compliance with advice to return to normal/stop sheltering, attend a facility for assessment and treatment, and return to a previously contaminated area after decontamination of the environment has taken place. Should a real attack with an RDD occur, having pretested messages available to address common concerns and information needs should facilitate the public health response to the attack.
A computer-guided minimally-invasive technique for orthodontic forced eruption of impacted canines.
BERTELè, Matteo; Minniti, Paola P; Dalessandri, Domenico; Bonetti, Stefano; Visconti, Luca; Paganelli, Corrado
2016-06-01
The aim of this study was to develop a computer-guided minimally-invasive protocol for the surgical application of an orthodontic traction during the forced eruption of an impacted canine. 3Diagnosys® software was used to evaluate impacted canines position and to plan the surgical access, taking into account soft and hard tissues thickness, orthodontic traction path and presence of possible obstacles. Geomagic® software was used for reverse engineering and RhinocerosTM software was employed as three-dimensional modeller in preparing individualized surgical guides. Surgical access was gained flapless through the use of a mucosal punch for soft tissues, followed by a trephine bur with a pre-adjusted stop for bone path creation. A diamond bur mounted on SONICflex® 2003/L handpiece was used to prepare a 2-mm-deep calibrated hole into the canine enamel where a titanium screw connected with a stainless steel ligature was screwed. In-vitro pull-out tests, radiological and SEM analysis were realized in order to investigate screw stability and position. In two out of ten samples the screw was removed after the application of a 1-kg pull-out force. Radiological and SEM analysis demonstrated that all the screws were inserted into the enamel without affecting dentine integrity. This computer-guided minimally-invasive technique allowed a precise and reliable positioning of screws utilized during the orthodontic traction of impacted canines.
Bordons, M; Morillo, F; Fernández, M T; Gómez, I
2006-01-01
The situation of Research in radiology in Spain is analysed by examining the number of publications by Spanish authors in main stream international journals. The scientific production of Spanish researchers in journals included in the Science Citation Index (SCI) under the headings "Radiology, Nuclear Medicine, and Medical Imaging" and "Neuroimaging" during the years 1996-2003. During this period the scientific production in these fields comprised 1,562 documents (3.5% of the total production for Spanish clinical medicine); scientific production in these fields increased by 40% in this period in comparison to 24% for all clinical medicine. The bulk of the production was concentrated in the autonomous communities of Catalonia (35%), Madrid (28%), and Valencia (10%). The autonomous communities of Navarra and Cantabria had a high relative production after the results were adjusted for population. The healthcare sector is the most active, with the Hospital de la Santa Creu i Sant Pau, the Hospital Clinic de Barcelona, and the Hospital Vall d'Hebron being outstanding in that they not only lead the country in the number of publications but also publish more in journals with high impact factors. Among centers other than hospitals, the Center for Research in Energy, the Environment, and Technologies (CIEMAT) and the Medical School of the Universidad Complutense de Madrid are the most important. A high degree of collaboration is evident: 68% of the documents were produced by more than one institution, foreign centers were involved in 20%, and the documents were signed by an average of six authors. Conclusions. In summary, the data show that Spanish radiological research is becomin increasingly international, although this process is still in the initial stage, with the percentage of documents published in the most prestigious journals for this specialty being lower than in other disciplines. The relative activity and production of Spain is slightly below the average of the European Union, but the country shows a rising trend for both production and impact.
Radiological impact of 2016 operations at the Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minter, K. L.; Jannik, G. T.; Dixon, K. M.
This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2016 Savannah River Site (SRS) air and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios, such as the consumption of wildlife or goat milk.
Sivasankar, Vaishnavi; Ranganathan, Kannan; Praveen, B
2014-01-01
Keratinizing dentigerous cyst is a rare entity. This article reports a case of keratinizing dentigerous cyst associated with an impacted mandibular canine. Clinical and radiological features, cone-beam computed tomography findings and histological features of the case are reported along with a discussion on keratinizing odontogenic cysts and the need for follow-up. PMID:24808713
External risk factors affecting construction costs
NASA Astrophysics Data System (ADS)
Mubarak, Husin, Saiful; Oktaviati, Mutia
2017-11-01
Some risk factors can have impacts on the cost, time, and performance. Results of previous studies indicated that the external conditions are among the factors which give effect to the contractor in the completion of the project. The analysis in the study carried out by considering the conditions of the project in the last 15 years in Aceh province, divided into military conflict phase (2000-2004), post tsunami disaster rehabilitation and reconstruction phase (2005-2009), and post-rehabilitation and reconstruction phase (2010-present). This study intended to analyze the impact of external risk factors, primarily related to the impact on project costs and to investigate the influence of the risk factors and construction phases impacted the project cost. Data was collected by using a questionnaire distributed in 15 large companies qualification contractors in Aceh province. Factors analyzed consisted of socio-political, government policies, natural disasters, and monetary conditions. Data were analyzed using statistical application of severity index to measure the level of risk impact. The analysis results presented the tendency of impact on cost can generally be classified as low. There is only one variable classified as high-impact, variable `fuel price increases', which appear on the military conflict and post tsunami disaster rehabilitation and reconstruction periods. The risk impact on costs from the factors and variables classified with high intensity needs a serious attention, especially when the high level impact is followed by the high frequency of occurrences.
Bailer, A John; Bena, James F; Stayner, Leslie T; Halperin, William E; Park, Robert M
2003-03-01
Fatal injury surveillance data provide an opportunity to assess the impact of occupational injuries and may indicate which industries or occupations are appreciably more hazardous than others, and thus should be given priority in public health intervention. Fatalities from the National Traumatic Occupational Fatality surveillance system served as the basis for examining external cause (E-code) specific impact summaries. Years of potential life lost (YPLL) were calculated for fatal injuries in the years 1983-1994. Industries and occupations were compared with respect to frequency of fatal injuries. In addition, injuries in categories of external causes are examined across all industries and occupations. Machinery, electric current, homicide, falls, and transportation-related are the external cause groups highlighted by high frequency/rate of occurrence. Electric current event groups are also characterized by high average YPLL. Poisoning, conflagration, and lightning were also identified in several occupations as having high associated average YPLL. The external-cause-specific analysis of average YPLL identified industries and occupations where, on average, younger workers were dying in fatal injuries. Noteworthy in this assessment were homicides and falls. The YPLL measure coupled with more commonly employed indices (e.g., rates) may provide a fuller description of the impact of occupational fatal injuries.
Laceulle, Odillia M.; Van Aken, Marcel A.G.; Ormel, Johan
2017-01-01
Abstract Personality similarity between parent and offspring has been suggested to play an important role in offspring's development of externalizing problems. Nonetheless, much remains unknown regarding the nature of this association. This study aimed to investigate the effects of parent–offspring similarity at different levels of personality traits, comparing expectations based on evolutionary and goodness‐of‐fit perspectives. Two waves of data from the TRAILS study (N = 1587, 53% girls) were used to study parent–offspring similarity at different levels of personality traits at age 16 predicting externalizing problems at age 19. Polynomial regression analyses and Response Surface Analyses were used to disentangle effects of different levels and combinations of parents and offspring personality similarity. Although several facets of the offspring's personality had an impact on offspring's externalizing problems, few similarity effects were found. Therefore, there is little support for assumptions based on either an evolutionary or a goodness‐of‐fit perspective. Instead, our findings point in the direction that offspring personality, and at similar levels also parent personality might impact the development of externalizing problems during late adolescence. © 2017 The Authors. European Journal of Personality published by John Wiley & Sons Ltd on behalf of European Association of Personality Psychology PMID:28303077
Low Velocity Blunt Impact on Lightweight Composite Sandwich Panels
NASA Astrophysics Data System (ADS)
Chan, Monica Kar
There is an increased desire to incorporate more composite sandwich structures into modern aircrafts. Because in-service aircrafts routinely experience impact damage during maintenance due to ground vehicle collision, dropped equipment, or foreign object damage (FOD) impact, it is necessary to understand their impact characteristics, particularly when blunt impact sources create internal damage with little or no external visibility. The objective of this investigation is to explore damage formation in lightweight composite sandwich panels due to low-velocity impacts of variable tip radius and energy level. The correlation between barely visible external dent formation and internal core damage was explored as a function of impact tip radius. A pendulum impactor was used to impact composite sandwich panels having honeycomb core while held in a 165 mm square window fixture. The panels were impacted by hardened steel tips with radii of 12.7, 25.4, 50.8, and 76.2 mm at energy levels ranging from 2 to 14 J. Experimental data showed little dependence of external dent depth on tip radius at very low energies of 2 to 6 J, and thus, there was also little variation in visibility due to tip radius. Four modes of internal core damage were identified. Internal damage span and depth were dependent on impact tip radius. Damage depth was also radius-dependent, but stabilized at constant depth independent of kinetic energy. Internal damage span increased with increasing impact energy, but not with increasing tip radius, suggesting a relationship between maximum damage tip radius with core density/size.
ERIC Educational Resources Information Center
Wade, Jordan L.; Cox, Neill Broderick; Reeve, Ronald E.; Hull, Michael
2014-01-01
Using data from the Simons Simplex Collection, the present study examined the impact of child externalizing behavior and parental broad autism phenotype traits on substance use among parents of children with autism spectrum disorder (n = 2,388). For both fathers and mothers, child externalizing behaviors predicted tobacco use (OR = 1.01 and OR =…
When Information Improves Information Security
NASA Astrophysics Data System (ADS)
Grossklags, Jens; Johnson, Benjamin; Christin, Nicolas
This paper presents a formal, quantitative evaluation of the impact of bounded-rational security decision-making subject to limited information and externalities. We investigate a mixed economy of an individual rational expert and several naïve near-sighted agents. We further model three canonical types of negative externalities (weakest-link, best shot and total effort), and study the impact of two information regimes on the threat level agents are facing.
ERIC Educational Resources Information Center
Powers, Kristina
2015-01-01
This chapter builds on prior chapters and focuses on higher education trends on the horizon and the resulting impact on external reporting for institutional researchers. Three practical recommendations and examples for institutional researchers are also presented.
ERIC Educational Resources Information Center
Ehren, Melanie C. M.; Godfrey, David
2017-01-01
This paper explores the impact of external accountability on four mechanisms of network-internal quality control and the properties of (mandated) inter-organizational networks. An explorative case study approach examines the external accountability of a newly established educational network (MAT) and how schools and the Trust are held accountable…
Impact of an in-house emergency radiologist on report turnaround time.
Lamb, Leslie; Kashani, Paria; Ryan, John; Hebert, Guy; Sheikh, Adnan; Thornhill, Rebecca; Fasih, Najla
2015-01-01
One of the many challenges facing emergency departments (EDs) across North America is timely access to emergency radiology services. Academic institutions, which are typically also regional referral centres, frequently require cross-sectional studies to be performed 24 hours a day with expedited final reports to accelerate patient care and ED flow. The purpose of this study was to determine if the presence of an in-house radiologist, in addition to a radiology resident dedicated to the ED, had a significant impact on report turnaround time. Preliminary and final report turnaround times, provided by the radiology resident and staff, respectively, for patients undergoing computed tomography or ultrasonography of their abdomen/pelvis in 2008 (before the implementation of emergency radiology in-house staff service) were compared to those performed during the same time frame in 2009 and 2010 (after staffing protocols were changed). A total of 1,624 reports were reviewed. Overall, there was no statistically significant decrease in the preliminary report turnaround times between 2008 and 2009 (p = 0.1102), 2009 and 2010 (p = 0.6232), or 2008 and 2010 (p = 0.0890), although times consistently decreased from a median of 2.40 hours to 2.08 hours to 2.05 hours (2008 to 2009 to 2010). There was a statistically significant decrease in final report turnaround times between 2008 and 2009 (p < 0.0001), 2009 and 2010 (p < 0.0011), and 2008 and 2010 (p < 0.0001). Median final report times decreased from 5.00 hours to 3.08 hours to 2.75 hours in 2008, 2009, and 2010, respectively. There was also a significant decrease in the time interval between preliminary and final reports between 2008 and 2009 (p < 0.0001) and 2008 and 2010 (p < 0.0001) but no significant change between 2009 and 2010 (p = 0.4144). Our results indicate that the presence of a dedicated ED radiologist significantly reduces final report turnaround time and thus may positively impact the time to ED patient disposition. Patient care is improved when attending radiologists are immediately available to read complex films, both in terms of health care outcomes and regarding the need for repeat testing. Providing emergency physicians with accurate imaging findings as rapidly as possible facilitates effective and timely management and thus optimizes patient care.
Severe traumatic injury during long duration spaceflight: Light years beyond ATLS.
Kirkpatrick, Andrew W; Ball, Chad G; Campbell, Mark; Williams, David R; Parazynski, Scott E; Mattox, Kenneth L; Broderick, Timothy J
2009-03-25
Traumatic injury strikes unexpectedly among the healthiest members of the human population, and has been an inevitable companion of exploration throughout history. In space flight beyond the Earth's orbit, NASA considers trauma to be the highest level of concern regarding the probable incidence versus impact on mission and health. Because of limited resources, medical care will have to focus on the conditions most likely to occur, as well as those with the most significant impact on the crew and mission. Although the relative risk of disabling injuries is significantly higher than traumatic deaths on earth, either issue would have catastrophic implications during space flight. As a result this review focuses on serious life-threatening injuries during space flight as determined by a NASA consensus conference attended by experts in all aspects of injury and space flight.In addition to discussing the impact of various mission profiles on the risk of injury, this manuscript outlines all issues relevant to trauma during space flight. These include the epidemiology of trauma, the pathophysiology of injury during weightlessness, pre-hospital issues, novel technologies, the concept of a space surgeon, appropriate training for a space physician, resuscitation of injured astronauts, hemorrhage control (cavitary and external), surgery in space (open and minimally invasive), postoperative care, vascular access, interventional radiology and pharmacology.Given the risks and isolation inherent in long duration space flight, a well trained surgeon and/or surgical capability will be required onboard any exploration vessel. More specifically, a broadly-trained surgically capable emergency/critical care specialist with innate capabilities to problem-solve and improvise would be desirable. It will be the ultimate remote setting, and hopefully one in which the most advanced of our societies' technologies can be pre-positioned to safeguard precious astronaut lives. Like so many previous space-related technologies, these developments will also greatly improve terrestrial care on earth.
Soil nematode assemblages as bioindicators of radiation impact in the Chernobyl Exclusion Zone.
Lecomte-Pradines, C; Bonzom, J-M; Della-Vedova, C; Beaugelin-Seiller, K; Villenave, C; Gaschak, S; Coppin, F; Dubourg, N; Maksimenko, A; Adam-Guillermin, C; Garnier-Laplace, J
2014-08-15
In radioecology, the need to understand the long-term ecological effects of radioactive contamination has been emphasised. This requires that the health of field populations is evaluated and linked to an accurate estimate of received radiological dose. The aim of the present study was to assess the effects of current radioactive contamination on nematode assemblages at sites affected by the fallout from the Chernobyl accident. First, we estimated the total dose rates (TDRs) absorbed by nematodes, from measured current soil activity concentrations, Dose Conversion Coefficients (DCCs, calculated using EDEN software) and soil-to-biota concentration ratios (from the ERICA tool database). The impact of current TDRs on nematode assemblages was then evaluated. Nematodes were collected in spring 2011 from 18 forest sites in the Chernobyl Exclusion Zone (CEZ) with external gamma dose rates, measured using radiophotoluminescent dosimeters, varying from 0.2 to 22 μGy h(-1). These values were one order of magnitude below the TDRs. A majority of bacterial-, plant-, and fungal-feeding nematodes and very few of the disturbance sensitive families were identified. No statistically significant association was observed between TDR values and nematode total abundance or the Shannon diversity index (H'). The Nematode Channel Ratio (which defines the relative abundance of bacterial- versus fungal-feeding nematodes) decreased significantly with increasing TDR, suggesting that radioactive contamination may influence nematode assemblages either directly or indirectly by modifying their food resources. A greater Maturity Index (MI), usually characterising better soil quality, was associated with higher pH and TDR values. These results suggest that in the CEZ, nematode assemblages from the forest sites were slightly impacted by chronic exposure at a predicted TDR of 200 μGy h(-1). This may be imputable to a dominant proportion of pollutant resistant nematodes in all sites. This might result from a selection at the expense of sensitive species after the accident. Copyright © 2013 Elsevier B.V. All rights reserved.
An assessment of the radiological impact of the Windscale reactor fire, October 1957.
Crick, M J; Linsley, G S
1984-11-01
On the 10th and 11 October 1957 a fire in the No 1 Pile at the Windscale establishment in Cumbria led to an uncontrolled release of activity to the atmosphere. The resultant cloud subsequently dispersed and radionuclides could be detected over England, Wales and parts of northern Europe. The extensive environmental measurements which were made during and after the release enabled a fairly accurate estimate to be made of the radiation doses to the most exposed individuals in the local population. Until recently, no estimates of the population dose resulting from the release had been published. This paper describes assessments which have been made by the NRPB of the population or collective dose from the release and of the possible associated health impact. In addition to the fission products that escaped, radionuclides were released from materials undergoing irradiation in the pile at the time of the fire. The assessment has included the results of a review of previously unpublished data which established the quantity of these nuclides released and considers their impact on both individual and population doses. The collective effective dose equivalent commitment from the release is estimated to have been 2.0 x 10(3) man Sv. The route of exposure which contributed the most to the collective dose was the inhalation pathway. Iodine-131 was the most important radionuclide, contributing nearly all of the collective dose to the thyroid and a large part of the collective effective dose. Polonium-210 and caesium-137 also made significant contributions; that from caesium-137 came in the longer term via external irradiation from ground deposits and the ingestion of contaminated foodstuffs. The methodology used in the study has been validated to a certain degree by comparing the predicted levels of individual thyroid activity and those measured directly in the weeks following the accident in London, Leeds and Cumbria.
Severe traumatic injury during long duration spaceflight: Light years beyond ATLS
Kirkpatrick, Andrew W; Ball, Chad G; Campbell, Mark; Williams, David R; Parazynski, Scott E; Mattox, Kenneth L; Broderick, Timothy J
2009-01-01
Traumatic injury strikes unexpectedly among the healthiest members of the human population, and has been an inevitable companion of exploration throughout history. In space flight beyond the Earth's orbit, NASA considers trauma to be the highest level of concern regarding the probable incidence versus impact on mission and health. Because of limited resources, medical care will have to focus on the conditions most likely to occur, as well as those with the most significant impact on the crew and mission. Although the relative risk of disabling injuries is significantly higher than traumatic deaths on earth, either issue would have catastrophic implications during space flight. As a result this review focuses on serious life-threatening injuries during space flight as determined by a NASA consensus conference attended by experts in all aspects of injury and space flight. In addition to discussing the impact of various mission profiles on the risk of injury, this manuscript outlines all issues relevant to trauma during space flight. These include the epidemiology of trauma, the pathophysiology of injury during weightlessness, pre-hospital issues, novel technologies, the concept of a space surgeon, appropriate training for a space physician, resuscitation of injured astronauts, hemorrhage control (cavitary and external), surgery in space (open and minimally invasive), postoperative care, vascular access, interventional radiology and pharmacology. Given the risks and isolation inherent in long duration space flight, a well trained surgeon and/or surgical capability will be required onboard any exploration vessel. More specifically, a broadly-trained surgically capable emergency/critical care specialist with innate capabilities to problem-solve and improvise would be desirable. It will be the ultimate remote setting, and hopefully one in which the most advanced of our societies' technologies can be pre-positioned to safeguard precious astronaut lives. Like so many previous space-related technologies, these developments will also greatly improve terrestrial care on earth. PMID:19320976
Effects of Hospital Workers' Friendship Networks on Job Stress.
Shin, Sung Yae; Lee, Sang Gyu
2016-01-01
This study attempted to identify the sources of job stress according to job position and investigate how friendship networks affect job stress. Questionnaires based on The Health Professions Stress Inventory (HPSI) developed by Wolfgang experienced by healthcare providers were collected from 420 nurses, doctors and radiological technologists in two general hospitals in Korea by a multistage cluster sampling method. Multiple regression analysis was used to examine the effects of friendship networks on job stress after controlling for other factors. The severity of job stress differed according to level of job demands (p = .006); radiologic technologists experienced the least stress (45.4), nurses experienced moderate stress (52.4), and doctors experienced the most stress (53.6). Those with long-term friendships characterized by strong connections reported lower levels of stress than did those with weak ties to friends among nurses (1.3, p < .05) and radiological technologists (11.4, p < .01). The degree of cohesion among friends had a positive impact on the level of job stress experienced by nurses (8.2, p < .001) and radiological technologists (14.6, p < .1). Doctors who participated in workplace alumni meetings scored higher than those who did not. However, those who participated in alumni meetings outside the workplace showed the opposite tendency, scoring 9.4 (p < .05) lower than those who did not. The resources from their friendship network include both information and instrumental support. As most radiological technologists were male, their instrumental support positively affected their job stress (9.2, p < .05). Life information support was the primary positive contributor to control of nurses' (4.1, p < .05), radiological technologists' (8.0, p < .05) job stress. The strength and density of such friendship networks were related to job stress. Life information support from their friendship network was the primary positive contributor to control of job stress.
Effects of Hospital Workers’ Friendship Networks on Job Stress
Shin, Sung Yae; Lee, Sang Gyu
2016-01-01
Background This study attempted to identify the sources of job stress according to job position and investigate how friendship networks affect job stress. Methods Questionnaires based on The Health Professions Stress Inventory (HPSI) developed by Wolfgang experienced by healthcare providers were collected from 420 nurses, doctors and radiological technologists in two general hospitals in Korea by a multistage cluster sampling method. Multiple regression analysis was used to examine the effects of friendship networks on job stress after controlling for other factors. Results The severity of job stress differed according to level of job demands (p = .006); radiologic technologists experienced the least stress (45.4), nurses experienced moderate stress (52.4), and doctors experienced the most stress (53.6). Those with long-term friendships characterized by strong connections reported lower levels of stress than did those with weak ties to friends among nurses (1.3, p < .05) and radiological technologists (11.4, p < .01). The degree of cohesion among friends had a positive impact on the level of job stress experienced by nurses (8.2, p < .001) and radiological technologists (14.6, p < .1). Doctors who participated in workplace alumni meetings scored higher than those who did not. However, those who participated in alumni meetings outside the workplace showed the opposite tendency, scoring 9.4 (p < .05) lower than those who did not. The resources from their friendship network include both information and instrumental support. As most radiological technologists were male, their instrumental support positively affected their job stress (9.2, p < .05). Life information support was the primary positive contributor to control of nurses’ (4.1, p < .05), radiological technologists’ (8.0, p < .05) job stress. Conclusion The strength and density of such friendship networks were related to job stress. Life information support from their friendship network was the primary positive contributor to control of job stress. PMID:26900945
Perl, Jeffrey; Pierratos, Andreas; Kandasamy, Gokulan; McCormick, Brendan B; Quinn, Robert R; Jain, Arsh K; Huang, Anjie; Paterson, J Michael; Oliver, Matthew J
2015-02-01
The likelihood of peritoneal dialysis (PD) utilization following a PD catheter insertion attempt is poorly described. We explored the risk factors for PD nonuse, focusing on the method of PD catheter implantation. This population-based retrospective cohort study employed Ontario administrative health data to identify 3886 predialysis adults who had an incident PD catheter implantation between 2002 and 2010. The impact of the method of catheter implantation including open-surgical (open, n = 1884), surgical-laparoscopic (laparoscopic, n = 1154), nephrology-percutaneous (nephrology, n = 498) and radiology-percutaneous (radiology, n = 350) on rates of PD utilization (defined as four consecutive weeks of PD) was examined. Eighty-three percent of study patients received PD. After adjustment, relative to patients with openly inserted catheters, PD utilization was greater for those with nephrology-inserted catheters [adjusted hazard ratio (aHR) 1.59, 95% confidence interval (CI) 1.29-1.95] and similar for radiology-inserted catheters [aHR 1.16, 95% CI 0.94-1.43] or laparoscopic-inserted catheters [aHR 0.97 (95% CI 0.86-1.09)]. Among PD nonusers, death occurred in 10% of the open group, 6% of the laparoscopic group, 27% of the radiology group and in fewer than 3% of the nephrology group. Sixty-nine percent received hemodialysis in the open group, 63% in the laparoscopic group, 61% in the radiology group and 88% in the nephrology group. Those remaining predialysis comprised 12% of the open group, 22% of the laparoscopic group, 11% of the radiology group and <3% of the nephrology group. Nephrology insertion resulted in lower overall rates of PD nonuse, particularly due to death or remaining predialysis. Greater use may be related to insertion timing, technique or greater commitment on the part of nephrologists to the success of PD. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haase, G.M.; Sfakianakis, G.N.; Lobe, T.E.
1981-06-01
The ability of external imaging to demonstrate intestinal infarction in neonatal necrotizing enterocolitis (NEC) was prospectively evaluated. The radiopharmaceutical technetium--99m diphosphonate was injected intravenously and the patients subsequently underwent abdominal scanning. Clinical patient care and interpretation of the images were entirely independent throughout the study. Of 33 studies, 7 were positive, 4 were suspicious, and 22 were negative. One false positive study detected ischemia without transmural infarction. The second false positive scan occurred postoperatively and was due to misinterpretation of the hyperactivity along the surgical incision. None of the suspicious cases had damaged bowel. The two false negative studies clearlymore » failed to demonstrate frank intestinal necrosis. The presence of very small areas of infarction, errors in technical settings, subjective interpretation of scans and delayed clearance of the radionuclide in a critically ill neonate may all limit the accuracy of external abdominal scanning. However, in spite of an error rate of 12%, it is likely that this technique will enhance the present clinical, laboratory, and radiologic parameters of patient management in NEC.« less